WorldWideScience

Sample records for radiation analysis system

  1. Robotic radiation survey and analysis system for radiation waste casks

    Thunborg, S.

    1987-01-01

    Sandia National Laboratories (SNL) and the Hanford Engineering Development Laboratories have been involved in the development of remote systems technology concepts for handling defense high-level waste (DHLW) shipping casks at the waste repository. This effort was demonstrated the feasibility of using this technology for handling DHLW casks. These investigations have also shown that cask design can have a major effect on the feasibility of remote cask handling. Consequently, SNL has initiated a program to determine cask features necessary for robotic remote handling at the waste repository. The initial cask handling task selected for detailed investigation was the robotic radiation survey and analysis (RRSAS) task. In addition to determining the design features required for robotic cask handling, the RRSAS project contributes to the definition of techniques for random selection of swipe locations, the definition of robotic swipe parameters, force control techniques for robotic swipes, machine vision techniques for the location of objects in 3-D, repository robotic systems requirements, and repository data management system needs

  2. Analysis of food radiation monitoring system in Belarus

    1992-01-01

    Food radiation monitoring system in Belarus due to the Chernobyl accident is analysed. Structure of radiation monitoring network, instrumentation and modern developments. Information on permissible concentration levels in foodstuffs and water is presented and calculations of radionuclide intake for man are performed. Proposals on the creation of social centres of food radiation monitoring for Belarussian population are considered. 4 tabs

  3. Reliability Analysis of the CERN Radiation Monitoring Electronic System CROME

    AUTHOR|(CDS)2126870

    For the new in-house developed CERN Radiation Monitoring Electronic System (CROME) a reliability analysis is necessary to ensure compliance with the statu-tory requirements regarding the Safety Integrity Level. The required Safety Integrity Level by IEC 60532 standard is SIL 2 (for the Safety Integrated Functions Measurement, Alarm Triggering and Interlock Triggering). The first step of the reliability analysis was a system and functional analysis which served as basis for the implementation of the CROME system in the software “Iso-graph”. In the “Prediction” module of Isograph the failure rates of all components were calculated. Failure rates for passive components were calculated by the Military Standard 217 and failure rates for active components were obtained from lifetime tests by the manufacturers. The FMEA was carried out together with the board designers and implemented in the “FMECA” module of Isograph. The FMEA served as basis for the Fault Tree Analysis and the detection of weak points...

  4. Radiation analysis for manned missions to the Jupiter system.

    De Angelis, G; Clowdsley, M S; Nealy, J E; Tripathi, R K; Wilson, J W

    2004-01-01

    An analysis for manned missions targeted to the Jovian system has been performed in the framework of the NASA RASC (Revolutionary Aerospace Systems Concepts) program on Human Exploration beyond Mars. The missions were targeted to the Jupiter satellite Callisto. The mission analysis has been divided into three main phases, namely the interplanetary cruise, the Jupiter orbital insertion, and the surface landing and exploration phases. The interplanetary phase is based on departure from the Earth-Moon L1 point. Interplanetary trajectories based on the use of different propulsion systems have been considered, with resulting overall cruise phase duration varying between two and five years. The Jupiter-approach and the orbital insertion trajectories are considered in detail, with the spacecraft crossing the Jupiter radiation belts and staying around the landing target. In the surface exploration phase the stay on the Callisto surface is considered. The satellite surface composition has been modeled based on the most recent results from the GALILEO spacecraft. In the transport computations the surface backscattering has been duly taken into account. Particle transport has been performed with the HZETRN heavy ion code for hadrons and with an in-house developed transport code for electrons and bremsstrahlung photons. The obtained doses have been compared to dose exposure limits. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.

  5. The Database and Data Analysis Software of Radiation Monitoring System

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2009-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150MeV injector, 3.5GeV booster, 3.5GeV storage ring and an amount of beam line stations. The data is fetched by the monitoring computer from collecting modules in the front end, and saved in the MySQL database in the managing computer. The data analysis software is coded with Python, a script language, to inquire, summarize and plot the data of a certain monitoring channel during a certain period and export to an external file. In addition, the warning event can be inquired separately. The website for historical and real-time data inquiry and plotting is coded with PHP. (authors)

  6. Nuisance Source Population Modeling for Radiation Detection System Analysis

    Sokkappa, P; Lange, D; Nelson, K; Wheeler, R

    2009-10-05

    A major challenge facing the prospective deployment of radiation detection systems for homeland security applications is the discrimination of radiological or nuclear 'threat sources' from radioactive, but benign, 'nuisance sources'. Common examples of such nuisance sources include naturally occurring radioactive material (NORM), medical patients who have received radioactive drugs for either diagnostics or treatment, and industrial sources. A sensitive detector that cannot distinguish between 'threat' and 'benign' classes will generate false positives which, if sufficiently frequent, will preclude it from being operationally deployed. In this report, we describe a first-principles physics-based modeling approach that is used to approximate the physical properties and corresponding gamma ray spectral signatures of real nuisance sources. Specific models are proposed for the three nuisance source classes - NORM, medical and industrial. The models can be validated against measured data - that is, energy spectra generated with the model can be compared to actual nuisance source data. We show by example how this is done for NORM and medical sources, using data sets obtained from spectroscopic detector deployments for cargo container screening and urban area traffic screening, respectively. In addition to capturing the range of radioactive signatures of individual nuisance sources, a nuisance source population model must generate sources with a frequency of occurrence consistent with that found in actual movement of goods and people. Measured radiation detection data can indicate these frequencies, but, at present, such data are available only for a very limited set of locations and time periods. In this report, we make more general estimates of frequencies for NORM and medical sources using a range of data sources such as shipping manifests and medical treatment statistics. We also identify potential data sources for industrial

  7. Thermal analysis of an HVAC system with TRV controlled hydronic radiator

    Tahersima, Fatemeh; Stoustrup, Jakob; Rasmussen, Henrik

    2010-01-01

    A model for an HVAC system is derived in this paper. The HVAC system consists of a room and a hydronic radiator with temperature regulating valve (TRV) which has a step motor to adjust the valve opening. The heating system and the room are simulated as a unit entity for thermal analysis and contr......A model for an HVAC system is derived in this paper. The HVAC system consists of a room and a hydronic radiator with temperature regulating valve (TRV) which has a step motor to adjust the valve opening. The heating system and the room are simulated as a unit entity for thermal analysis...... and controller design. A discrete-element model with interconnected small scaled elements is proposed for the radiator. This models the radiator more precisely than that of a lumped model in terms of transfer delay and radiator gain. This precise modeling gives us an intuition into a regular unwanted phenomenon...... which occurs in low demand situations. When flow is very low in radiator and the supply water temperature and the pressure drop across the valve is constant, oscillation in room temperature occurs. One reason could be the large gain of radiator in low demand conditions compared to the high demand...

  8. INSREC: Computational System for Quantitative Analysis of Radiation Effects Covering All Radiation Field

    Dong Hoon Shin; Young Wook Lee; Young Ho Cho; Hyun Seok Ko; SukHoon Kim; YoungMin Kim; Chang Sun Kang

    2006-01-01

    In the nuclear energy field, there are so many difficult things that even people who are working in this field are not much familiar with, such as, Dose evaluation, Dose management, etc. Thus, so many efforts have been done to achieve the knowledge and data for understanding. Although some data had been achieved, the applications of these data to necessary cases were more difficult job. Moreover, the type of Dose evaluation program until now was 'Console type' which is not easy enough to use for the beginners. To overcome the above causes of difficulties, the window-based integrated program and database management were developed in our research lab. The program, called as INSREC, consists of four sub-programs as follow; INSREC-NOM, INSREC-ACT, INSREC-MED, and INSREC-EXI. In ICONE 11 conference, INSREC-program(ICONE-36203) which can evaluates on/off-site dose of nuclear power plant in normal operation was introduced. Upgraded INSREC-program which will be presented in ICONE 14 conference has three additional codes comparing with pre-presented INSREC-program. Those subprograms can evaluate on/off-site Dose of nuclear power plant in accident cases. And they also have the functions of 'Dose evaluation and management' in the hospital and provide the 'Expert system' based on knowledge related to nuclear energy/radiation field. The INSREC-NOM, one of subprograms, is composed of 'Source term evaluation program', 'Atmospheric diffusion factor evaluation program', 'Off-site dose evaluation program', and 'On-site database program'. The INSREC-ACT is composed of 'On/Off-site dose evaluation program' and 'Result analysis program' and the INSREC-MED is composed of 'Workers/patients dose database program' and 'Dose evaluation program for treatment room'. The final one, INSREC-EXI, is composed of 'Database searching program based on artificial intelligence', 'Instruction program,' and 'FAQ/Q and A boards'. Each program was developed by using of Visual C++, Microsoft Access mainly

  9. Counterbalanced radiation detection system

    Platz, W.

    1987-01-01

    A counterbalanced radiation detection system is described comprising: (a) a stand; (b) a first radiation detector; (c) a first radiation detector arm means for tiltably connecting the first radiation detector with the stand; (d) a second radiation detector; (e) a second radiation detector arm means for tiltably connecting the second radiation detector with the stand, whereby the tilting angles of the radiation detector arm means define a distance between the radiation detectors; and (f) a torque transforming means connected between the first and second radiation detector arm means for transforming the torque created by one of the radiation detectors in a sense opposed to the torque created by the other radiation detector

  10. Multi-criteria analysis on how to select solar radiation hydrogen production system

    Badea, G.; Naghiu, G. S., E-mail: naghiu.george@gmail.com; Felseghi, R.-A.; Giurca, I., E-mail: giurca-ioan@yahoo.com [Technical University of Cluj-Napoca, Faculty of Building Services Engineering, Boulevard December 21, no. 128-130, Cluj-Napoca, 400604 (Romania); Răboacă, S. [National R& D Institute for Cryogenic and Isotopic Technologies, str. Uzinei, no. 4, Rm. Vălcea, 240050 (Romania); Aşchilean, I. [SC ACI Cluj SA, Avenue Dorobanţilor, no. 70, Cluj-Napoca, 400609 (Romania)

    2015-12-23

    The purpose of this article is to present a method of selecting hydrogen-production systems using the electric power obtained in photovoltaic systems, and as a selecting method, we suggest the use of the Advanced Multi-Criteria Analysis based on the FRISCO formula. According to the case study on how to select the solar radiation hydrogen production system, the most convenient alternative is the alternative A4, namely the technical solution involving a hydrogen production system based on the electrolysis of water vapor obtained with concentrated solar thermal systems and electrical power obtained using concentrating photovoltaic systems.

  11. Systems analysis and engineering of the X-1 Advanced Radiation Source

    Rochau, G.E.; Hands, J.A.; Raglin, P.S.; Ramirez, J.J.

    1998-01-01

    The X-1 Advanced Radiation Source, which will produce ∼ 16 MJ in x-rays, represents the next step in providing US Department of Energy's Stockpile Stewardship program with the high-energy, large volume, laboratory x-ray sources needed for the Radiation Effects Science and Simulation (RES), Inertial Confinement Fusion (ICF), and Weapon Physics (WP) Programs. Advances in fast pulsed power technology and in z-pinch hohlraums on Sandia National Laboratories' Z Accelerator in 1997 provide sufficient basis for pursuing the development of X-1. This paper will introduce the X-1 Advanced Radiation Source Facility Project, describe the systems analysis and engineering approach being used, and identify critical technology areas being researched

  12. Estimation of monthly solar radiation distribution for solar energy system analysis

    Coskun, C.; Oktay, Z.; Dincer, I.

    2011-01-01

    The concept of probability density frequency, which is successfully used for analyses of wind speed and outdoor temperature distributions, is now modified and proposed for estimating solar radiation distributions for design and analysis of solar energy systems. In this study, global solar radiation distribution is comprehensively analyzed for photovoltaic (PV) panel and thermal collector systems. In this regard, a case study is conducted with actual global solar irradiation data of the last 15 years recorded by the Turkish State Meteorological Service. It is found that intensity of global solar irradiance greatly affects energy and exergy efficiencies and hence the performance of collectors. -- Research highlights: → The first study to apply global solar radiation distribution in solar system analyzes. → The first study showing global solar radiation distribution as a parameter of the solar irradiance intensity. → Time probability intensity frequency and probability power distribution do not have similar distribution patterns for each month. → There is no relation between the distribution of annual time lapse and solar energy with the intensity of solar irradiance.

  13. Application of systems and control theory-based hazard analysis to radiation oncology.

    Pawlicki, Todd; Samost, Aubrey; Brown, Derek W; Manger, Ryan P; Kim, Gwe-Ya; Leveson, Nancy G

    2016-03-01

    Both humans and software are notoriously challenging to account for in traditional hazard analysis models. The purpose of this work is to investigate and demonstrate the application of a new, extended accident causality model, called systems theoretic accident model and processes (STAMP), to radiation oncology. Specifically, a hazard analysis technique based on STAMP, system-theoretic process analysis (STPA), is used to perform a hazard analysis. The STPA procedure starts with the definition of high-level accidents for radiation oncology at the medical center and the hazards leading to those accidents. From there, the hierarchical safety control structure of the radiation oncology clinic is modeled, i.e., the controls that are used to prevent accidents and provide effective treatment. Using STPA, unsafe control actions (behaviors) are identified that can lead to the hazards as well as causal scenarios that can lead to the identified unsafe control. This information can be used to eliminate or mitigate potential hazards. The STPA procedure is demonstrated on a new online adaptive cranial radiosurgery procedure that omits the CT simulation step and uses CBCT for localization, planning, and surface imaging system during treatment. The STPA procedure generated a comprehensive set of causal scenarios that are traced back to system hazards and accidents. Ten control loops were created for the new SRS procedure, which covered the areas of hospital and department management, treatment design and delivery, and vendor service. Eighty three unsafe control actions were identified as well as 472 causal scenarios that could lead to those unsafe control actions. STPA provides a method for understanding the role of management decisions and hospital operations on system safety and generating process design requirements to prevent hazards and accidents. The interaction of people, hardware, and software is highlighted. The method of STPA produces results that can be used to improve

  14. Radiation monitoring system

    Takeuchi, Nobuyoshi; Fujimoto, Toshiaki; Nagama, Hideyo

    2007-01-01

    A positive outlook toward nuclear power plants and a higher level of technologies for using radiation in the medical field are trends that are spreading throughout the world, and as a consequence, demand is increasing for equipment and systems that measure and control radiation. Equipment ranging from radiation detection and measurement devices to computer-based radiation management systems will be set up in overseas. Products that depend on overseas specifications based on IEC and other international standards are being developed. Fuji Electric is advancing the overseas deployment of radiation monitoring systems by adopting measures that will ensure the reliability and traceability of radiation equipment. (author)

  15. Fused Silica Final Optics for Inertial Fusion Energy: Radiation Studies and System-Level Analysis

    Latkowski, Jeffery F.; Kubota, Alison; Caturla, Maria J.; Dixit, Sham N.; Speth, Joel A.; Payne, Stephen A.

    2003-01-01

    The survivability of the final optic, which must sit in the line of sight of high-energy neutrons and gamma rays, is a key issue for any laser-driven inertial fusion energy (IFE) concept. Previous work has concentrated on the use of reflective optics. Here, we introduce and analyze the use of a transmissive final optic for the IFE application. Our experimental work has been conducted at a range of doses and dose rates, including those comparable to the conditions at the IFE final optic. The experimental work, in conjunction with detailed analysis, suggests that a thin, fused silica Fresnel lens may be an attractive option when used at a wavelength of 351 nm. Our measurements and molecular dynamics simulations provide convincing evidence that the radiation damage, which leads to optical absorption, not only saturates but that a 'radiation annealing' effect is observed. A system-level description is provided, including Fresnel lens and phase plate designs

  16. Versatile radiation gaging system

    Long, P.J.

    1978-01-01

    The attributes of computerized versatile radiation gaging systems are described. The gages are used to measure plating thicknesses and material characteristics that can be determined from radiation attenuation and/or x-ray fluorescence measurements

  17. Radiation detecting system

    1975-01-01

    In spectrophotometry systems, a usual arrangement for modulating the radiation is a rotating disc having one or more sectors removed. A beam of radiation may be blocked by the disc except when a cut-away sector is in the path of the beam. With a double-beam system, a cut-away sector of 180 0 may be used so that when the first path is blocked, the second is allowed through, and vice versa. One or both sides of the disc may be formed as mirrors to facilitate beam switching and to allow use of more than two beams for background compensation purposes or for analysis of more than one substance within a sample. (G.T.H.)

  18. Survey and analysis of radiation safety management systems at medical institutions. Initial report. Radiation protection supervisor, radiation safety organization, and education and training

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2005-01-01

    In this study, a questionnaire survey was carried out to determine the actual situation of radiation safety management systems in Japanese medical institutions with nuclear medicine facilities. The questionnaire consisted of questions concerning the Radiation Protection Supervisor license, safety management organizations, and problems related to education and training in safety management. Analysis was conducted according to region, type of establishment, and number of beds. The overall response rate was 60%, and no significant difference in response rate was found among regions. Medical institutions that performed nuclear medicine practices without a radiologist participating accounted for 10% of the total. Medical institutions where nurses gave patients intravenous injections of radiopharmaceuticals as part of the nuclear medicine practices accounted for 28% of the total. Of these medical institutions, 59% provided education and training in safety management for nurses. The rate of acquisition of Radiation Protection Supervisor licenses was approximately 70% for radiological technologists and approximately 20% for physicians (regional difference, p=0.02). The rate of medical institutions with safety management organizations was 71% of the total. Among the medical institutions (n=208) without safety management organizations, approximately 56% had 300 beds or fewer. In addition, it became clear that 35% of quasi-public organizations and 44% of private organizations did not provide education and training in safety management (p<0.001, according to establishment). (author)

  19. Spacecraft radiator systems

    Anderson, Grant A. (Inventor)

    2012-01-01

    A spacecraft radiator system designed to provide structural support to the spacecraft. Structural support is provided by the geometric "crescent" form of the panels of the spacecraft radiator. This integration of radiator and structural support provides spacecraft with a semi-monocoque design.

  20. Integrative radiation systems biology

    Unger, Kristian

    2014-01-01

    Maximisation of the ratio of normal tissue preservation and tumour cell reduction is the main concept of radiotherapy alone or combined with chemo-, immuno- or biologically targeted therapy. The foremost parameter influencing this ratio is radiation sensitivity and its modulation towards a more efficient killing of tumour cells and a better preservation of normal tissue at the same time is the overall aim of modern therapy schemas. Nevertheless, this requires a deep understanding of the molecular mechanisms of radiation sensitivity in order to identify its key players as potential therapeutic targets. Moreover, the success of conventional approaches that tried to statistically associate altered radiation sensitivity with any molecular phenotype such as gene expression proofed to be somewhat limited since the number of clinically used targets is rather sparse. However, currently a paradigm shift is taking place from pure frequentistic association analysis to the rather holistic systems biology approach that seeks to mathematically model the system to be investigated and to allow the prediction of an altered phenotype as the function of one single or a signature of biomarkers. Integrative systems biology also considers the data from different molecular levels such as the genome, transcriptome or proteome in order to partially or fully comprehend the causal chain of molecular mechanisms. An example for the application of this concept currently carried out at the Clinical Cooperation Group “Personalized Radiotherapy in Head and Neck Cancer” of the Helmholtz-Zentrum München and the LMU Munich is described. This review article strives for providing a compact overview on the state of the art of systems biology, its actual challenges, potential applications, chances and limitations in radiation oncology research working towards improved personalised therapy concepts using this relatively new methodology

  1. Maintenance of radiation monitoring systems

    Aoyama, Kei

    2001-01-01

    As the safety and quality of atomic power facilities are more strongly required, the reliability improvement and preventive maintenance of radiation monitoring systems are important. This paper describes the maintenance of radiation monitoring systems delivered by Fuji Electric and the present status of preventive maintenance technology. Also it introduces the case that we developed a fault diagnosis function adopting a statistics technique and artificial intelligence (AI) and delivered a radiation monitoring system including this function. This system can output a fault analysis result and a countermeasure from the computer in real time. (author)

  2. Radiation signal processing system

    Bennett, M.; Knoll, G.; Strange, D.

    1980-01-01

    An improved signal processing system for radiation imaging apparatus comprises: a radiation transducer producing transducer signals proportional to apparent spatial coordinates of detected radiation events; means for storing true spatial coordinates corresponding to a plurality of predetermined apparent spatial coordinates relative to selected detected radiation events said means for storing responsive to said transducer signal and producing an output signal representative of said true spatial coordinates; and means for interpolating the true spatial coordinates of the detected radiation events located intermediate the stored true spatial coordinates, said means for interpolating communicating with said means for storing

  3. Thermal-hydraulic analysis of the improved TOPAZ-II power system using a heat pipe radiator

    Zhang, Wenwen; Zhang, Dalin, E-mail: dlzhang@mail.xjtu.edu.cn; Tian, Wenxi; Qiu, Suizheng; Su, G.H.

    2016-10-15

    Highlights: • The system thermal-hydraulic model of the improved space thermionic reactor is developed. • The temperature reactivity feedback effects of the moderator, UO2 fuel, electrodes and reflector are considered. • The alkali metal heat pipe radiator is modeled with the two dimensional heat pipe model. • The steady state and the start-up procedure of the system are analyzed. - Abstract: A system analysis code coupled with the heat pipe model is developed to analyze the thermal-hydraulic characteristics of the improved TOPAZ-II reactor power system with a heat pipe radiator. The core thermal-hydraulic model, neutron physics model, and the coolant loop component models (including pump, volume accumulator, pipes and plenums) are established. The designed heat pipe radiator, which replaces the original pumped loop radiator, is also modeled, including two-dimensional heat pipe analysis model, fin model and coolant transport duct model. The system analysis code and the heat pipe model is coupled in the transport duct model. Steady state condition and start-up procedure of the improved TOPAZ-II system are calculated. The results show that the designed radiator can satisfy the waste heat rejection requirement of the improved power system. Meanwhile, the code can be used to obtained the thermal characteristics of the system transients such as the start-up process.

  4. RTP Radiation Monitoring System

    Alfred, S.L.; Mohd Fairus Abdul Farid; Ahmad Nabil Abdul Rahim; Nurhayati Ramli

    2015-01-01

    Radiation Monitoring System aiming to limiting dose exposed to personnel to the lowest level referring to the concept of ALARA (As Low As Reasonably Achievable). Atomic Energy Licensing (Basic Safety Radiation Protection) Regulation 2010 (Act 304) is a baseline to control employee and public radiation protection program and guideline, as well as to meet the requirement of the Occupational Safety and Health 1994 (Act 514). (author)

  5. Measurement and analysis of the electric field radiation in pulsed power system of linear induction accelerator

    Cheng Qifeng; Ni Jianping; Meng Cui; Cheng Cheng; Liu Yinong; Li Jin

    2009-01-01

    The close of high voltage switch in pulsed power system of linear induction accelerator often radiates strong transient electric field, which may influence ambient sensitive electric equipment, signals and performance of other instruments, etc. By performing gridded measurement around the Marx generator, the general distribution law and basic characters of electric field radiation are summarized. The current signal of the discharge circuit is also measured, which demonstrates that the current and the radiated electric field both have a resonance frequency about 150 kHz, and contain much higher frequency components. (authors)

  6. Semiconductor radiation detection systems

    2010-01-01

    Covers research in semiconductor detector and integrated circuit design in the context of medical imaging using ionizing radiation. This book explores other applications of semiconductor radiation detection systems in security applications such as luggage scanning, dirty bomb detection and border control.

  7. Digital radiation monitor system

    Quan Jinhu; Zhai Yongchun; Guan Junfeng; Ren Dangpei; Ma Zhiyuan

    2003-01-01

    The article introduced digital radiation monitor system. The contents include: how to use advanced computer net technology to establish equipment net for nuclear facility, how to control and manage measuring instruments on field equipment net by local area net, how to manage and issue radiation monitoring data by internet

  8. Radiation control system

    Murao, Mitsuo.

    1985-01-01

    Purpose: To rapidly and suitably performing planning and designation by radiation-working control systems in the radiation controlled area of nuclear power plant. Method: Various informations regarding radiation exposure are arranged and actual exposure data are statistically stored, to thereby perform forecasting calculation for the radiation exposure upon workings in the plurality of working regions in the radiation controlled area. Based on the forecast values and the registered workers' exposure dose in the past workings are alocated successively such that the total exposure does upon conducting the workings is less than the limited value, to prepare working plans in the areas. Further, procedures for preparing a series of documents regarding the workings in the radiation area are automated to rapidly and properly provide the informations serving to the planning and designation for the radiation workings. As a result, the radiation managers' burnden can be mitigated and an efficient working management system can be provided, in view of the exposure management and personal management. (Kamimura, M.)

  9. About using of the high-speed modular computing structures in the systems of radiation express analysis

    Ermalitski, F A

    1996-12-31

    In accordance with parallel processing conception the original method for definition of the stream intensity of Poisson group is proposed, which is able to use for radiation express analysis. Within the framework of this method the parallel measure-calculating procedure is created and the high-speed modular computing system is designed for its implementation. 5 refs.

  10. Project and construction of a measurement system and nuclear radiations analysis

    Castro, R. B. de.

    1983-01-01

    A counting system was designed and built, aiming to: detect and measure nuclear radiations using a Geiger-Mueller counter; and to measure the amplitudes of pulses from either a proportional or a NaI detector. The results obtained of the Cs-137 and Co-60 energy spectra were compared with results obtained from other researches. (Author) [pt

  11. Analysis of radiation doses for a transportation system and its interface operations for commercial spent fuel

    Schneider, K.J.; Ross, W.A.; Smith, R.I.; Wilmot, E.L.

    1987-07-01

    This paper gives the results of estimates of aggregated radiation doses to the affected public and workers in the US that would be associated with loading spent fuel at the reactors, transporting the spent fuel by truck and rail, and receiving and unloading the spent fuel at a deep geological repository. The estimates are for a postulated transportation-related system using current state-of-the-art technology, if employed in the high-level waste management system in the future, and the approximate dose reduction from some potential system improvements. The results of the study provide a starting point for the US Department of Energy (DOE) to develop an improved transportation system that is cost effective, safe, and results in low radiation doses. 4 refs., 1 figs., 5 tabs

  12. Radiation detection system

    Whited, R.C.

    A system for obtaining improved resolution in relatively thick semiconductor radiation detectors, such as HgI/sub 2/, which exhibit significant hole trapping. Two amplifiers are used: the first measures the charge collected and the second the contribution of the electrons to the charge collected. The outputs of the two amplifiers are utilized to unfold the total charge generated within the detector in response to a radiation event.

  13. Comparative analysis of different approaches to the computation of long-wave radiation balance of water air systems

    Zhukovskii, K.; Nourani, Y.; Monte, L.

    1999-01-01

    In the present paper, the net long-wave radiation balance of the water-air environmental systems is analysed on the base of several semi-empirical approaches. Various theoretical models of infrared atmospheric radiation are reviewed. Factors, affecting their behavior are considered. Special attention is paid to physical conditions under which those models are applicable. Atmospheric and net infrared radiation fluxes are computed and compared under clear and cloudy sky. Results are presented in graphical form. Conclusions are made on the applicability of models considered for evaluating infrared radiation fluxes in environmental conditions of Central Italy. On the base of present analysis Anderson's model is chosen for future calculations of heat budget of lakes in Central Italy [it

  14. Solar radiation transfer and performance analysis of an optimum photovoltaic/thermal system

    Zhao Jiafei; Song Yongchen; Lam, Wei-Haur; Liu Weiguo; Liu Yu; Zhang Yi; Wang DaYong

    2011-01-01

    This paper presents the design optimization of a photovoltaic/thermal (PV/T) system using both non-concentrated and concentrated solar radiation. The system consists of a photovoltaic (PV) module using silicon solar cell and a thermal unit based on the direct absorption collector (DAC) concept. First, the working fluid of the thermal unit absorbs the solar infrared radiation. Then, the remaining visible light is transmitted and converted into electricity by the solar cell. This arrangement prevents excessive heating of the solar cell which would otherwise negatively affects its electrical efficiency. The optical properties of the working fluid were modeled based on the damped oscillator Lorentz-Drude model satisfying the Kramers-Kroenig relations. The coefficients of the model were retrieved by inverse method based on genetic algorithm, in order to (i) maximize transmission of solar radiation between 200 nm and 800 nm and (ii) maximize absorption in the infrared part of the spectrum from 800 nm to 2000 nm. The results indicate that the optimum system can effectively and separately use the visible and infrared part of solar radiation. The thermal unit absorbs 89% of the infrared radiation for photothermal conversion and transmits 84% of visible light to the solar cell for photoelectric conversion. When reducing the mass flow rate, the outflow temperature of the working fluid reaches 74 o C, the temperature of the PV module remains around 31 o C at a constant electrical efficiency about 9.6%. Furthermore, when the incident solar irradiance increases from 800 W/m 2 to 8000 W/m 2 , the system generates 196 o C working fluid with constant thermal efficiency around 40%, and the exergetic efficiency increases from 12% to 22%.

  15. Environmental radiation monitoring system

    Kato, Tsutomu; Shioiri, Masatoshi; Sakamaki, Tsuyoshi

    2007-01-01

    Environmental radiation monitoring systems are used to measure and monitoring gamma-rays at the observation boundaries of nuclear facilities and in the surrounding areas. In recent years, however, few new nuclear facilities have been constructed and the monitoring systems shift to renewal of existing systems. In addition, in order to increase public acceptance, the facilities are being equipped with communication lines to provide data to prefectural environmental centers. In this text, we introduce the latest technology incorporated in replacement of environmental radiation monitoring systems. We also introduce a replacement method that can shorten the duration during which environmental dose rate measurement is interrupted by enabling both the replacement system and the system being replaced to perform measurements in parallel immediately before and after the replacement. (author)

  16. Analysis and radiation dose rate measurement of the Al-1050 capsule on the rabbit system facility

    Sarwani; Sutrisno; H, Saleh; Rohidi; M, Kawkab

    2000-01-01

    Aluminium is a kind of light metal with density of 2.7 gram /cm exp 3,regarding to the aluminium is characteristic such as easy to fabricated,has a good corrosion resistant and radiation heat resistant, therefore aluminum is selected to be used as a material for sample irradiation capsule with high neutron fluency. Analysis using neutron activation method and capsule irradiation by using high neutron fluency and dose radiation rate measurement was done. The analysis result show that impurities in the Al-1050 capsule are Fe, Cu, Mg, Sb, Zn, and Mn. The capsule irradiated at 15 MW during 6 Hours with neutron fluency of 2,8 x 10 exp 17 n/cm exp 2. The radiation doses rate after 24 hours decay is 220 mrad/h at 0-meter distance and 60 mrad/h at 1-meter distance. Respectively. From the analysis results and measurement show that the Al-1050 capsule has no high neutron absorption element and available to get continuing irradiation at 15 MW as far as 6 hours. Due to the personal safety, therefore the capsule handling could be carried out in the hot cell

  17. Environmental radiation telemetering system

    Kikuchi, Hideo

    1983-01-01

    The Atomic Energy Center of Miyagi Prefecture introduced a telemetering system in 1982 for the purpose of monitoring human external exposure to radiation, and started preliminary examination for the radiation monitoring aound the Onagawa Nuclear Power Station, Tohoku Electric Power Co., in October, 1982, prior to its commencement of operation scheduled in June, 1984. This system roughly consists of three elements: monitoring stations (MSs) for the continuous observation of radiation, weather condition and other items; the monitoring center to collect the primary data obtained in each MS and to implement on-line data computation, data filing and display; and sub-centers for informing the data obtained by each MS to the people around it. Six MSs were installed in the region of radius of several km from the nuclear power plant. All or a part of the following items are measured in MSs: exposure on a basis of DBM (descrimination bias modulation), γ-spectra, exposure data of ionization chambers, wind direction and speed, rainfall, moisture in the ground, temperature, sunshine and radiation balance. In addition, in this report, also the system configuration, and online and off-line data processing are described. Environmental radiation does not seem to be fully grasped because it complicatedly varies due to weather conditions and other causes. The monitoring method of Miyagi Prefecture is expected to aid the clarification, though it is not yet established. (Wakatsuki, Y.)

  18. Spectral analysis for systems of atoms and molecules coupled to the quantized radiation field

    Bach, V.; Sigal, I.M.

    1999-01-01

    We consider systems of static nuclei and electrons - atoms and molecules - coupled to the quantized radiation field. The interactions between electrons and the soft modes of the quantized electromagnetic field are described by minimal coupling, p→p-eA(x), where A(x) is the electromagnetic vector potential with an ultraviolet cutoff. If the interactions between the electrons and the quantized radiation field are turned off, the atom or molecule is assumed to have at least one bound state. We prove that, for sufficiently small values of the fine structure constant α, the interacting system has a ground state corresponding to the bottom of its energy spectrum. For an atom, we prove that its excited states above the ground state turn into metastable states whose life-times we estimate. Furthermore the energy spectrum is absolutely continuous, except, perhaps,in a small interval above the ground state energy and around the threshold energies of the atom or molecule. (orig.)

  19. Radiation analysis devices, radiation analysis methods, and articles of manufacture

    Roybal, Lyle Gene

    2010-06-08

    Radiation analysis devices include circuitry configured to determine respective radiation count data for a plurality of sections of an area of interest and combine the radiation count data of individual of sections to determine whether a selected radioactive material is present in the area of interest. An amount of the radiation count data for an individual section is insufficient to determine whether the selected radioactive material is present in the individual section. An article of manufacture includes media comprising programming configured to cause processing circuitry to perform processing comprising determining one or more correction factors based on a calibration of a radiation analysis device, measuring radiation received by the radiation analysis device using the one or more correction factors, and presenting information relating to an amount of radiation measured by the radiation analysis device having one of a plurality of specified radiation energy levels of a range of interest.

  20. Radiation effects on living systems

    Hawley, N.J.

    1980-10-01

    This bibliography includes papers and reports by Atomic Energy of Canada Limited scientists concerning radiation effects on living systems. It is divided into three sections: Radiobiology, Radiation Biochemistry and Radiation Chemistry. (auth)

  1. Radiation oncology systems integration

    Ragan, D.P.

    1991-01-01

    ROLE7 is intended as a complementary addition to the HL7 Standard and not as an alternative standard. Attempt should be made to mould data elements which are specific to radiation therapy with existing HL7 elements. This can be accomplished by introducing additional values to some element's table-of-options. Those elements which might be specific to radiation therapy could from new segments to be added to the Ancillary Data Reporting set. In order to accomplish ROLE7, consensus groups need be formed to identify the various functions related to radiation oncology that might motivate information exchange. For each of these functions, the specific data elements and their format must be identified. HL7 is organized with a number of applications which communicate asynchronously. Implementation of ROLE7 would allow uniform access to information across vendors and functions. It would provide improved flexibility in system selection. It would allow a more flexible and affordable upgrade path as systems in radiation oncology improve. (author). 5 refs

  2. Systems analysis of radiation safety during dismantling of power-plant equipment at a nuclear power station

    Bylkin, B.K.; Shpitser, V.Ya.

    1993-01-01

    A systems analysis of the radiation safety makes possible an ad hoc determination of the elements forming the system, as well as the establishment of the characteristics of their interaction with radiation-effect factors. Here the authors will present part of the hierarchical analysis procedure, consisting in general of four separate procedures. The purpose is to investigate and analyze the mean and stable (on the average) indices of radiation safety, within the framework of alternative mathematical models of dismantling the power-plant equipment of a nuclear power station. The following three of the four procedures are discussed: (1) simulated projection, of the processing of radioactive waste; (2) analysis of the redistribution of radionuclides during the industrial cycle of waste treatment; (3) planning the collective dose load during the dismantling operation. Within the framework of the first of these procedures, the solutions to the problem of simulating a waste-treatment operation of maximum efficiency are analyzed. This analysis is based on the use of a data base for the parameters of the installations, assemblies, and equipment, enabling the integration of these in a simulation of a complex automated facility. The results were visualized in an AUTOCAD-10 medium using a graphical data base containing an explanation of the rooms

  3. Radiation detection system

    Haeuszer, F.A.

    1976-01-01

    A circuit is disclosed that detects radiation transients and provides a clamping signal in response to each transient. The clamping signal is present from the time the transient rises above a given threshold level and for a known duration thereafter. The system includes radiation sensors, a blocking oscillator that generates a pulse in response to each sensor signal, and an output pulse duration control circuit. The oscillator pulses are fed simultaneously to the output pulse duration control circuit and to an OR gate, the output of which comprises the system output. The output pulse duration is controlled by the time required to magnetize a magnetic core to saturation in first one direction and then the other

  4. A synchrotron radiation microtomography system for the analysis of trabecular bone samples.

    Salomé, M; Peyrin, F; Cloetens, P; Odet, C; Laval-Jeantet, A M; Baruchel, J; Spanne, P

    1999-10-01

    X-ray computed microtomography is particularly well suited for studying trabecular bone architecture, which requires three-dimensional (3-D) images with high spatial resolution. For this purpose, we describe a three-dimensional computed microtomography (microCT) system using synchrotron radiation, developed at ESRF. Since synchrotron radiation provides a monochromatic and high photon flux x-ray beam, it allows high resolution and a high signal-to-noise ratio imaging. The principle of the system is based on truly three-dimensional parallel tomographic acquisition. It uses a two-dimensional (2-D) CCD-based detector to record 2-D radiographs of the transmitted beam through the sample under different angles of view. The 3-D tomographic reconstruction, performed by an exact 3-D filtered backprojection algorithm, yields 3-D images with cubic voxels. The spatial resolution of the detector was experimentally measured. For the application to bone investigation, the voxel size was set to 6.65 microm, and the experimental spatial resolution was found to be 11 microm. The reconstructed linear attenuation coefficient was calibrated from hydroxyapatite phantoms. Image processing tools are being developed to extract structural parameters quantifying trabecular bone architecture from the 3-D microCT images. First results on human trabecular bone samples are presented.

  5. Signal and noise analysis of a-Si:H radiation detector-amplifier system

    Cho, Gyuseong.

    1992-03-01

    Hydrogenated amorphous silicon (a-Si:H) has potential advantages in making radiation detectors for many applications because of its deposition capability on a large-area substrate and its high radiation resistance. Position-sensitive radiation detectors can be made out of a 1d strip or a 2-d pixel array of a Si:H pin diodes. In addition, signal processing electronics can be made by thin-film transistors on the same substrate. The calculated radiation signal, based on a simple charge collection model agreed well with results from various wave length light sources and 1 MeV beta particles on sample diodes. The total noise of the detection system was analyzed into (a) shot noise and (b) 1/f noise from a detector diode, and (c) thermal noise and (d) 1/f noise from the frontend TFT of a charge-sensitive preamplifier. the effective noise charge calculated by convoluting these noise power spectra with the transfer function of a CR-RC shaping amplifier showed a good agreement with the direct measurements of noise charge. The derived equations of signal and noise charge can be used to design an a-Si:H pixel detector amplifier system optimally. Signals from a pixel can be readout using switching TFTs, or diodes. Prototype tests of a double-diode readout scheme showed that the storage time and the readout time are limited by the resistances of the reverse-biased pixel diode and the forward biased switching diodes respectively. A prototype charge-sensitive amplifier was made using poly-Si TFTs to test the feasibility of making pixel-level amplifiers which would be required in small-signal detection. The measured overall gain-bandwidth product was ∼400 MHz and the noise charge ∼1000 electrons at a 1 μsec shaping time. When the amplifier is connected to a pixel detector of capacitance 0.2 pF, it would give a charge-to-voltage gain of ∼0.02 mV/electron with a pulse rise time less than 100 nsec and a dynamic range of 48 dB

  6. Signal and noise analysis of a-Si:H radiation detector-amplifier system

    Cho, Gyuseong [Univ. of California, Berkeley, CA (United States)

    1992-03-01

    Hydrogenated amorphous silicon (a-Si:H) has potential advantages in making radiation detectors for many applications because of its deposition capability on a large-area substrate and its high radiation resistance. Position-sensitive radiation detectors can be made out of a 1d strip or a 2-d pixel array of a Si:H pin diodes. In addition, signal processing electronics can be made by thin-film transistors on the same substrate. The calculated radiation signal, based on a simple charge collection model agreed well with results from various wave length light sources and 1 MeV beta particles on sample diodes. The total noise of the detection system was analyzed into (a) shot noise and (b) 1/f noise from a detector diode, and (c) thermal noise and (d) 1/f noise from the frontend TFT of a charge-sensitive preamplifier. the effective noise charge calculated by convoluting these noise power spectra with the transfer function of a CR-RC shaping amplifier showed a good agreement with the direct measurements of noise charge. The derived equations of signal and noise charge can be used to design an a-Si:H pixel detector amplifier system optimally. Signals from a pixel can be readout using switching TFTs, or diodes. Prototype tests of a double-diode readout scheme showed that the storage time and the readout time are limited by the resistances of the reverse-biased pixel diode and the forward biased switching diodes respectively. A prototype charge-sensitive amplifier was made using poly-Si TFTs to test the feasibility of making pixel-level amplifiers which would be required in small-signal detection. The measured overall gain-bandwidth product was ~400 MHz and the noise charge ~1000 electrons at a 1 μsec shaping time. When the amplifier is connected to a pixel detector of capacitance 0.2 pF, it would give a charge-to-voltage gain of ~0.02 mV/electron with a pulse rise time less than 100 nsec and a dynamic range of 48 dB.

  7. Signal and noise analysis of a-Si:H radiation detector-amplifier system

    Cho, Gyuseong.

    1992-03-01

    Hydrogenated amorphous silicon (a-Si:H) has potential advantages in making radiation detectors for many applications because of its deposition capability on a large-area substrate and its high radiation resistance. Position-sensitive radiation detectors can be made out of a 1d strip or a 2-d pixel array of a Si:H pin diodes. In addition, signal processing electronics can be made by thin-film transistors on the same substrate. The calculated radiation signal, based on a simple charge collection model agreed well with results from various wave length light sources and 1 MeV beta particles on sample diodes. The total noise of the detection system was analyzed into (a) shot noise and (b) 1/f noise from a detector diode, and (c) thermal noise and (d) 1/f noise from the frontend TFT of a charge-sensitive preamplifier. the effective noise charge calculated by convoluting these noise power spectra with the transfer function of a CR-RC shaping amplifier showed a good agreement with the direct measurements of noise charge. The derived equations of signal and noise charge can be used to design an a-Si:H pixel detector amplifier system optimally. Signals from a pixel can be readout using switching TFTs, or diodes. Prototype tests of a double-diode readout scheme showed that the storage time and the readout time are limited by the resistances of the reverse-biased pixel diode and the forward biased switching diodes respectively. A prototype charge-sensitive amplifier was made using poly-Si TFTs to test the feasibility of making pixel-level amplifiers which would be required in small-signal detection. The measured overall gain-bandwidth product was {approximately}400 MHz and the noise charge {approximately}1000 electrons at a 1 {mu}sec shaping time. When the amplifier is connected to a pixel detector of capacitance 0.2 pF, it would give a charge-to-voltage gain of {approximately}0.02 mV/electron with a pulse rise time less than 100 nsec and a dynamic range of 48 dB.

  8. Radiation shielding analysis

    Moon, S.H.; Ha, C.W.; Kwon, S.K.; Lee, J.K.; Choi, H.S.

    1982-01-01

    The theoretical bases of radiation streaming analysis in power reactors, such as ducts or reactor cavity, have been investigated. Discrete ordinates-Monte Carlo or Monte Carlo-Monte Carlo coupling techniques are suggested for the streaming analysis of ducts or reactor cavity. Single albedo scattering approximation code (SINALB) has been developed for simple and quick estimation of gamma-ray ceiling scattering, where the ceiling is assumed to be semi-infinite medium. This code has been employed to calculate the gamma-ray ceiling scattering effects in the laboratory containing a Co-60 source. The SINALB is applicable to gamma-ray scattering, only where the ceiling is thicker than Σsup(-1) and the height is at least twice higher than the shield wall. This code can be used for the purpose of preliminary radiation shield design. The MORSE code has been improved to analyze the gamma-ray scattering problem with on approximation method in respect to the random walk and estimation processes. This improved MORSE code has been employed to the gamma-ray ceiling scattering problem. The results of the improved MORSE calculation are in good agreement with the SINALB and standard MORSE. (Author)

  9. Radiation early warning system

    Schmitzer, C.; Kloesch, W.; Stadtmann, H.

    1993-01-01

    A prototype station for a Radiation Early Warning Network has been designed and set up at the Austrian Research Centre Seibersdorf. This unit was developed to measure all relevant parameters necessary to detect and track radioactive contamination at an early stage. The station consists of the following components: Radiation measuring channel for ambient gamma dose rate. Meteorological measurement channels for air temperature and humidity, wind direction and wind speed, and precipitation. Data processing and storage unit. The system is capable of unattended operation and data acquisition even under adverse environmental conditions. Connection to a central processing platform may be achieved via leased line, dial up over public switched telephone network (PSTN), or radio-frequency transmission. The remote station will continue acquiring and storing data for at least a month, even if the communications link is broken. Multiple stations can be combined to form a network, providing detailed information about radiological and meteorological data at each site. Thus increased ambient radiation levels may be discovered, tracked, and forecasted based on calculations using current and local weather data

  10. Probabilistic safety analysis about the radiation risk for the driver in a fast-scan container/vehicle inspection system

    Li Junli; Zhu Guoping; Ming Shenjin; Cao Yanfeng

    2008-01-01

    A new Container/Vehicle Inspection System called fast-scan inspection system has been developed and used in some countries, which has a special advantage in scanning efficiency of 200 - 400 containers per hour. However, for its unique scanning mode, the fast-scan inspection system causes some worries about the radiation risk for the truck drivers, who will drive the container truck to pass through the scanning tunnel and might be exposed by the radiation beam in accidents. A PSA analysis, which has been widely used to evaluate the safety of nuclear power plant in the past, is presented here to estimate the probability of accidental exposure to the driver and evaluate the health risk. The fault tree and event tree analysis show that the probability of accidental exposure to the driver is pretty low and the main failure contributions are human errors and scanning control devices failures, which provides some recommendations for the further improvement about this product. Furthermore, on the basic of ICRP No.60 and 76 reports, the health risk to the truck driver is only about 4.0x10 -14 /a. Compared with the exempt level of 5x10 -7 /a, it can be concluded that the fast-scan system is safe enough for the truck driver. (author)

  11. Analysis of a radiative heat exchanger for systems for thermal control of space vehicles

    Vasil'ev, L.L.; Kanonchik, L.E.; Babenko, V.A.

    1995-01-01

    Starting from the solution of a two-dimensional heat conduction problem, a mathematical model of a heat pipe-based radiative heat exchanger is developed. Good agreement between the predicted and experimental results is obtained. The effect of operational and structural parameters on the characteristics of the radiative heat exchanger is analyzed

  12. Data management, documentation and analysis systems in radiation oncology: a multi-institutional survey

    Kessel, Kerstin A.; Combs, Stephanie E.

    2015-01-01

    Recently, information availability has become more elaborate and widespread, and treatment decisions are based on a multitude of factors. Gathering relevant data, also referred to as Big Data, is therefore critical for reaching the best patient care, and enhancing interdisciplinary and clinical research. Combining patient data from all involved systems is essential to prepare unstructured data for analyses. This demands special coordination in data management. Our study aims to characterize current developments in German-speaking hospital departments and practices. We successfully conducted the survey with the members of the Deutsche Gesellschaft für Radioonkologie (DEGRO). A questionnaire was developed consisting of 17 questions related to data management, documentation and clinical trial analyses, reflecting the clinical topics such as basic patient information, imaging, follow-up information as well as connection of documentation tools with radiooncological treatment planning machines. A total of 44 institutions completed the online survey (University hospitals n = 17, hospitals n = 13, practices/institutes n = 14). University hospitals, community hospitals and private practices are equally equipped concerning IT infrastructure for clinical use. However, private practices have a low interest in research work. All respondents stated the biggest obstacles about introducing a documentation system into their unit lie in funding and support of the central IT departments. Only 27 % (12/44) of responsible persons are specialists for documentation and data management. Our study gives an understanding of the challenges and solutions we need to be looking at for medical data storage. In the future, inter-departmental cross-links will enable the radiation oncology community to generate large-scale analyses. The online version of this article (doi:10.1186/s13014-015-0543-0) contains supplementary material, which is available to authorized users

  13. Hybrid radiator cooling system

    France, David M.; Smith, David S.; Yu, Wenhua; Routbort, Jules L.

    2016-03-15

    A method and hybrid radiator-cooling apparatus for implementing enhanced radiator-cooling are provided. The hybrid radiator-cooling apparatus includes an air-side finned surface for air cooling; an elongated vertically extending surface extending outwardly from the air-side finned surface on a downstream air-side of the hybrid radiator; and a water supply for selectively providing evaporative cooling with water flow by gravity on the elongated vertically extending surface.

  14. Monitoring System For Improving Radiation Safety Management

    Osovizky, A.; Paran, J.; Tal, N.; Ankry, N.; Ashkenazi, B.; Tirosh, D.; Marziano, R.; Chisin, R.

    1999-01-01

    Medi SMARTS (Medical Survey Mapping Automatic Radiation Tracing System), a gamma radiation monitoring system, was installed in a nuclear medicine department. In this paper the evaluation of the system's ability to improve radiation safety management is presented. The system is based on a state of the art software that continuously collects on line radiation measurements for display, analysis and logging. Radiation is measured by GM tubes; the signal is transferred to a data processing unit and then via an RS-485 communication line to a computer. The system automatically identifies the detector type and its calibration factor, thus providing compatibility, maintainability and versatility when changing detectors. Radiation levels are displayed on the nuclear medicine department map at six locations. The system has been operating continuously for more than one year, documenting abnormal events caused by routine operation or failure incidents. In cases where abnormal working conditions were encountered, an alarm message was sent automatically to the supervisor via his tele-pager. An interesting issue observed during the system evaluation, was the inability to distinguish between high radiation levels caused by proper routine operation and those caused by safety failure incidents. The solution included examination of two parameters, radiation levels as well as their duration period. A careful analysis of the historical data, applying the appropriated combined parameters determined for each location, verified that such a system can identify abnormal events, provide alarms to warn in case of incidents and improve standard operating procedures

  15. Radiation effects on living systems

    Hawley, N.J.

    1984-04-01

    This bibliography includes papers and reports by Atomic Energy of Canada Limited scientists concerning radiation effects on living systems. It is divided into three sections: Radiobiology, Radiation Biochemistry and Radiation Chemistry. It is intended that the bibliography will be updated regularly

  16. Development of environment radiation database management system

    Kang, Jong Gyu; Chung, Chang Hwa; Ryu, Chan Ho; Lee, Jin Yeong; Kim, Dong Hui; Lee, Hun Sun [Daeduk College, Taejon (Korea, Republic of)

    1999-03-15

    In this development, we constructed a database for efficient data processing and operating of radiation-environment related data. Se developed the source documents retrieval system and the current status printing system that supports a radiation environment dta collection, pre-processing and analysis. And, we designed and implemented the user interfaces and DB access routines based on WWW service policies on KINS Intranet. It is expected that the developed system, which organizes the information related to environmental radiation data systematically can be utilize for the accurate interpretation, analysis and evaluation.

  17. Development of environment radiation database management system

    Kang, Jong Gyu; Chung, Chang Hwa; Ryu, Chan Ho; Lee, Jin Yeong; Kim, Dong Hui; Lee, Hun Sun

    1999-03-01

    In this development, we constructed a database for efficient data processing and operating of radiation-environment related data. Se developed the source documents retrieval system and the current status printing system that supports a radiation environment dta collection, pre-processing and analysis. And, we designed and implemented the user interfaces and DB access routines based on WWW service policies on KINS Intranet. It is expected that the developed system, which organizes the information related to environmental radiation data systematically can be utilize for the accurate interpretation, analysis and evaluation

  18. New type radiation management system

    Mogi, Kenichi; Uranaka, Yasuo; Fujita, Kazuhiko

    2001-01-01

    The radiation management system is a system to carry out entrance and leaving room management of peoples into radiation management area, information management on radiation obtained from a radiation testing apparatus, and so on. New type radiation management system developed by the Mitsubishi Electric Corp. is designed by concepts of superior maintenance and system practice by using apparatus and its interface with standard specification, upgrading of processing response by separating exposure management processing from radiation monitoring processing on a computer, and a backup system not so as to lose its function by a single accident of the constructed computer. Therefore, the system is applied by the newest hardware, package software, and general use LAN, and can carry out a total system filled with requirements and functions for various radiation management of customers by preparing a basic system from radiation testing apparatus to entrance and leaving room management system. Here were described on outline of the new type management system, concept of the system, and functions of every testing apparatus. (G.K.)

  19. Development of radiation dose assessment system for radiation accident (RADARAC)

    Takahashi, Fumiaki; Shigemori, Yuji; Seki, Akiyuki

    2009-07-01

    The possibility of radiation accident is very rare, but cannot be regarded as zero. Medical treatments are quite essential for a heavily exposed person in an occurrence of a radiation accident. Radiation dose distribution in a human body is useful information to carry out effectively the medical treatments. A radiation transport calculation utilizing the Monte Carlo method has an advantageous in the analysis of radiation dose inside of the body, which cannot be measured. An input file, which describes models for the accident condition and quantities of interest, should be prepared to execute the radiation transport calculation. Since the accident situation, however, cannot be prospected, many complicated procedures are needed to make effectively the input file soon after the occurrence of the accident. In addition, the calculated doses are to be given in output files, which usually include much information concerning the radiation transport calculation. Thus, Radiation Dose Assessment system for Radiation Accident (RADARAC) was developed to derive effectively radiation dose by using the MCNPX or MCNP code. RADARAC mainly consists of two parts. One part is RADARAC - INPUT, which involves three programs. A user can interactively set up necessary resources to make input files for the codes, with graphical user interfaces in a personnel computer. The input file includes information concerning the geometric structure of the radiation source and the exposed person, emission of radiations during the accident, physical quantities of interest and so on. The other part is RADARAC - DOSE, which has one program. The results of radiation doses can be effectively indicated with numerical tables, graphs and color figures visibly depicting dose distribution by using this program. These results are obtained from the outputs of the radiation transport calculations. It is confirmed that the system can effectively make input files with a few thousand lines and indicate more than 20

  20. Radiation effluent suppression system

    Watanabe, Atsushi.

    1992-01-01

    In a radiation release suppression system upon accident, an electromotive valve, a pneumatic operation valve or a manual operation valve is disposed to gas ventilation pipelines which are extended from both of a dry well and a wet well of a reactor container to a stuck. In addition, a combination filter of a metal fiber filter made of stainless steel etc. and an activated carbon fiber filter is disposed in the midway of pipelines in a reactor building. With such a constitution, the inside of the container can be depressurized (prevention of ruptures) and the amount of radioactive substances released to circumstances is remarkably suppressed by the effect of radioactive substance capturing effect of the metal fiber filter made of stainless steel etc. disposed in the vent pipe in the container and a radioactive substance capturing effect by the combination filter of the metal fiber filter made of stainless steel, etc. and the activated carbon fiber filter disposed in the gas ventilation pipelines even upon occurrence of an accident exceeding design basis. Systems can be simplified and minimized, and cost down can also be attained. (N.H.)

  1. Radiation analysis of the CIT (Compact Ignition Tokamak) pellet injector system and its impact on personnel access

    Selcow, E.C.; Stevens, P.N.; Gomes, I.C.; Gomes, L.M.

    1987-01-01

    Conceptual design of the Compact Ignition Tokamak (CIT) is near completion. This short-pulse ignition experiment is planned to follow the operations of the Tokamak Fusion Test Reactor (TFTR) at the Princeton Plasma Physics Laboratory. The high neutron wall loadings, /approximately/4-5 MW/m/sup 2/, associated with the operation of this device require that neutronics-related issues be considered in the overall system design. Radiation shielding is required for the protection of device components and personnel. A close-in igloo shield has been designed around the periphery of the tokamak structure, and the entire experiment is housed in a circular test cell facility with a radius of /approximately/12 m. The most critical radiation concern in the CIT design process relates to the numerous penetrations in the device. This paper discusses the impact of a major penetration on the design and operations of the CIT pellet injection system. The pellet injector is a major component, which has a line-of-sight penetration through the igloo and test cell wall. All current options for maintenance of the injector require personnel access. A nuclear analysis has been performed to determine the feasibility of hands-on access. Results indicate that personnel access to the pellet injector glovebox is possible. 10 refs., 3 figs., 3 tabs.

  2. ERMS - Environmental Radiation Monitoring System

    Vax, Eran; Sarusi, Benny; Sheinfeld, Mati; Levinson, Shmuel; Brandys, Irad; Sattinger, Danny; Wengrowicz, Udi; Tshuva, Avi; Tirosh, Dan

    2008-01-01

    A new Environmental Radiation Monitoring System (ERMS) has been developed in the NRCN as an extensive tool to be applied in case of nuclear malfunction or Nuclear Disposal Device (NDD) incident, as well as for routine radiation monitoring of the reactor's vicinity. The system collects real-time environmental data such as: gamma radiation, wind speed, wind direction, and temperature for monitoring purposes. The ERMS consists of a main Control Center and an array of monitoring stations. Fixed, environmental, gamma radiation monitoring stations are installed at the reactor's surroundings while portable stations can be posted rapidly along the wind direction, enhancing the spatial sampling of the radiation measurements and providing better hazard assessment at an emergency event. The presented ERMS, based on industrial standards for hardware and network protocols, is a reliable standalone system which upgrades the readiness to face a nuclear emergency event by supplying real-time, integrated meteorological and radiation data. (author)

  3. Analysis of dicentrics in human lymphocytes exposed to ionizing radiation using the automated system and optical microscope

    Martinez A, J.

    2016-01-01

    Ionizing radiation is a form of energy that produces ionizations in the molecules it traverses. When the higher energy radiation interacts with the structure of human chromosomes, chromosome aberrations, mainly of the dicentric type, are the union of two damaged chromosomes, represented by two centromeres and non centromere fragment. There are situations where a population of people may be affected by the release of any radioactive material and it is impossible to determine in a short time the absorbed dose to which each person was exposed. The dicentrics analysis from the culture of human lymphocytes is used to estimate doses of exposure to ionizing radiation, using the optical microscope. The objective of this work is to analyze dicentric chromosomal lesions, using the optical microscope in comparison with the semi-automated system, to respond promptly to radiological emergencies. For this study, two samples irradiated with "6"0Co were analyzed, one in the Instituto Nacional de Investigaciones Nucleares (ININ) reaching doses of 2.7 ± 0.1 and 0.85 ± 0.1 Gy, and the other in Walischmiller Engineering G mb H, Markdorf (Germany) reaching doses of 0.84 ± 0.3 and 2.8 ± 0.1 Gy. A lymphocyte culture was performed following the recommendations of the IAEA, using minimum essential MEM medium previously prepared with BrdU, sodium heparin, antibiotic and L-glutamine. Phytohemagglutinin, fetal calf serum was added to the sample, incubated at 37 degrees Celsius for 48 hours and three hours before the end of incubation, colcemide was placed. KCl post-culture was added and lamellae were prepared by washing with the 3:1 acid-acetic fixative solution and a Giemsa staining. 1000 cell readings were performed using the optical microscope and the automated system according to study protocols and quality standards to estimate absorbed dose by means of dicentric analysis, defined by ISO-19238. With the automated system similar results of absorbed dose were obtained with respect to

  4. FT-IR microscopical analysis with synchrotron radiation: The microscope optics and system performance

    Reffner, J.A.; Martoglio, P.A.; Williams, G.P.

    1995-01-01

    When a Fourier transform infrared (FT-IR) microspectrometer was first interfaced with the National Synchrotron Light Source (NSLS) in September 1993, there was an instant realization that the performance at the diffraction limit had increased 40-100 times. The synchrotron source transformed the IR microspectrometer into a true IR microprobe, providing high-quality IR spectra for probe diameters at the diffraction limit. The combination of IR microspectroscopy and synchrotron radiation provides a powerful new tool for molecular spectroscopy. The ability to perform IR microspectroscopy with synchrotron radiation is still under development at Brookhaven National Laboratory, but several initial studies have been completed that demonstrate the broad-ranging applications of this technology and its potential for materials characterization

  5. FT-IR microscopical analysis with synchrotron radiation: The microscope optics and system performance

    Reffner, J.A.; Martoglio, P.A. [Spectra-Tech, Inc., Shelton, CT (United States); Williams, G.P. [Brookhaven National Lab., Upton, NY (United States)

    1995-01-01

    When a Fourier transform infrared (FT-IR) microspectrometer was first interfaced with the National Synchrotron Light Source (NSLS) in September 1993, there was an instant realization that the performance at the diffraction limit had increased 40-100 times. The synchrotron source transformed the IR microspectrometer into a true IR microprobe, providing high-quality IR spectra for probe diameters at the diffraction limit. The combination of IR microspectroscopy and synchrotron radiation provides a powerful new tool for molecular spectroscopy. The ability to perform IR microspectroscopy with synchrotron radiation is still under development at Brookhaven National Laboratory, but several initial studies have been completed that demonstrate the broad-ranging applications of this technology and its potential for materials characterization.

  6. Generalized indices for radiation risk analysis

    Bykov, A.A.; Demin, V.F.

    1989-01-01

    A new approach to ensuring nuclear safety has begun forming since the early eighties. The approach based on the probabilistic safety analysis, the principles of acceptable risk, the optimization of safety measures, etc. has forced a complex of adequate quantitative methods of assessment, safety analysis and risk management to be developed. The method of radiation risk assessment and analysis hold a prominent place in the complex. National and international research and regulatory organizations ICRP, IAEA, WHO, UNSCEAR, OECD/NEA have given much attention to the development of the conceptual and methodological basis of those methods. Some resolutions of the National Commission of Radiological Protection (NCRP) and the Problem Commission on Radiation Hygiene of the USSR Ministry of Health should be also noted. Both CBA (cost benefit analysis) and other methods of radiation risk analysis and safety management use a system of natural and socio-economic indices characterizing the radiation risk or damage. There exist a number of problems associated with the introduction, justification and use of these indices. For example, the price, a, of radiation damage, or collective dose unit, is a noteworthy index. The difficulties in its qualitative and quantitative determination are still an obstacle for a wide application of CBA to the radiation risk analysis and management. During recent 10-15 years these problems have been a subject of consideration for many authors. The present paper also considers the issues of the qualitative and quantitative justification of the indices of radiation risk analysis

  7. Radiation analysis of the CIT [Compact Ignition Tokamak] pellet injector system and its impact on personnel access

    Selcow, E.C.; Stevens, P.N.; Gomes, I.C.; Gomes, L.M.

    1988-08-01

    The conceptual design of the Compact Ignition Tokamak (CIT) is nearing completion. The CIT is a short-pulse ignition experiment, which is planned to follow the operations of the Tokamak Fusion Test Reactor (TFTR) at the Princeton Plasma Physics Laboratory (PPPL). The high neutron wall loadings, 4--5 MW/m 2 , associated with the operation of this device require that neutronics-related issues be considered in the overall system design. Radiation shielding is required for the protection of device components as well as personnel. A close-in igloo shield has been designed around the periphery of the tokamak structure, and the entire experiment is housed in a circular test cell facility that has a radius of 12 m. The most critical radiation concerns in the CIT design process relate to the numerous penetrations in the device. This report discusses the impact of a major penetration on the design and operation of the pellet injection system in the CIT. The pellet injector is a major component, and it has a line-of-sight penetration through the igloo and test cell wall. All current options for maintenance of the injector require hands-on-access. A nuclear analysis has been performed to establish the feasibility of hands-on-access. A coupled Monte Carlo/discrete-ordinates methodology was used to perform the analysis. This problem is characterized by deep penetration and streaming with very large length-to-diameter ratios. Results from this study indicate that personnel access to the pellet injector glovebox is possible. 14 refs., 3 figs., 3 tabs

  8. Radiation monitoring system

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  9. Radiation monitoring system

    Aghina, Mauricio A.C.; Farias, Marcos S. de; Lacerda, Fabio de; Heimlich, Adino

    2015-01-01

    Design of a portable low-power multichannel analyzer with wireless connectivity for remote radiation monitoring, powered from a solar panel with a internal battery to be operated in field. The multichannel analyzer is based on a single microcontroller which performs the digital functions and an analog signal processing board for implementing a Gaussian shaper preamplifier, a Gaussian stretcher, sample and hold, pile-up rejector and a 10 bit ADC. Now this design is to be used with a NaI(Ti) scintillator detector. This multichannel analyzer is designed to be a part of radiation monitoring network. All of them are connected, by radio in a radius of 10 kilometers, to a supervisor computer that collects data from the network of multichannel analyzers and numerically display the latest radiation measurements or graphically display measurements over time for all multichannel analyzers. Like: dose rate, spectra and operational status. Software also supports remotely configuring operating parameters (such as radiation alarm level) for each monitor independently. (author)

  10. Radiation intensity counting system

    Peterson, R.J.

    1982-01-01

    A method is described of excluding the natural dead time of the radiation detector (or eg Geiger-Mueller counter) in a ratemeter counting circuit, thus eliminating the need for dead time corrections. Using a pulse generator an artificial dead time is introduced which is longer than the natural dead time of the detector. (U.K.)

  11. Radiation-resistant control system

    Cable, T.C.; Jones, S.

    1995-01-01

    REMOTEC has developed a open-quotes radiation resistanceclose quotes control system under a U.S. Department of Energy Small Business Innovative Research (SBIR) contract with assistance from the University of Florida. The SBIR goal was to develop a radiation resistant mobile robot from the ANDROS family of hazardous duty mobile robots that REMOTEC manufactures. See Refs. 1 and 2 for additional SBIR results. The control system, as well as the entire ANDROS robot, was redesigned, where necessary, to withstand radiation doses in excess of 10 6 rad. Those components of the robot that could not be purchased as open-quotes radiation hardenedclose quotes were tested under standard operating conditions for determination of their open-quotes radiation resistance.close quotes The entire ANDROS robot was then assembled with these new components and tested to > 10 6 rad

  12. Dosimetry systems for radiation processing

    McLaughlin, W.L.; Desrosiers, M.F.

    1995-01-01

    Dosimetry serves important functions in radiation processing, where large absorbed doses and dose rates from photon and electron sources have to be measured with reasonable accuracy. Proven dosimetry systems are widely used to perform radiation measurements in development of new processes, validation, qualification and verification (quality control) of established processes and archival documentation of day-to-day and plant-to-plant processing uniformity. Proper calibration and traceability of routine dosimetry systems to standards are crucial to the success of many large-volume radiation processes. Recent innovations and advances in performance of systems that enhance radiation measurement assurance and process diagnostics include dose-mapping media (new radiochromic film and solutions), optical waveguide systems for food irradiation, solid-state devices for real-time and passive dosimetry over wide dose-rate and dose ranges, and improved analytical instruments and data acquisition. (author)

  13. ON A SYSTEM FOR INFORMATION ANALYSIS (SCIENCE INDEX OF INNOVATIVE ACTIVITIES OF RUSSIAN ORGANIZATIONS IN THE FIELD OF RADIATION HYGIENE AND MEDICINE

    V. I. Evdokimov

    2013-01-01

    Full Text Available Science Index system for information analysis is one of effective modern indexes of innovative activity of Russian research and educational personnel, research and educational institutions. However, it should be noted that this assessment system does not yet include such important parameters as data on patent analysis and dissertation research. The article describes information search and preliminary bibliometric assessment of publication activity of the authors and some research institutions and periodicals in the field of radiation hygiene and medicine.

  14. Radiation detection systems

    Rozsa, Sandor

    1989-01-01

    Principles and operation of radiation detectors used for industrial and laboratory radiometric measurements are reviewed. The discussed detector types are as follows: ionization chamber, proportional counter, Geiger-Mueller counter, semiconductor detectors, scintillation counter and scintillators, photomultiplier tube, scintillation spectrometer and scintillation detector with semiconductor light sensor. A brief overview of the detectors of industrial nuclear instruments is also presented. (R.P.) 32 figs.; 3 tabs

  15. Radiation-induced transformation in oncogene primed C3H/10T1/2 cells; a new system for analysis of multi-step transformation in vitro

    Drozdoff, V.V.

    1988-01-01

    Several established rodent cell lines, such as C3H/10T1/2 fibroblasts, have been developed to study radiation and chemically-induced malignant transformation. Most experimental evidence has supported the idea that transformation in 10T1/2 cells involved at least two steps but that the apparent frequency of transformation depends on the density of plated cells. A new approach is presented here for studying radiation-induced transformation. An oncogene primed cell system (C3H-myc) was developed by introducing a constitutively active mouse c-myc gene into 10T1/2 cells. A primary goal was to determine if the introduction of an activated oncogene could substitute for one of the required steps in radiation-induced transformation. Results are presented that show that the expression of the exogenous myc gene significantly increased the frequency of radiation-induced transformation in these cells. Subculture experiments performed to analyze the kinetics of transformation in C3H-myc cells and reconstruction experiments allowing the effects of normal cells on radiation-induced transformants to be determined indicated that transformed cells arose very shortly after irradiation. These results support the conclusion that a radiation-induced event can complement the effect of myc in C3H-myc cells and directly result in transformation. This system thus provides an opportunity to isolate early steps in radiation-induced transformation and should facilitate the identification and analysis of these events

  16. Radiation induced peroxidation in model lipid systems

    Dahlan, K.Z.B.H.M.

    1981-08-01

    In the studies of radiation induced lipid peroxidation, lecithin-liposomes and aqueous micellar solutions of sodium linoleate (or linoleic acid) have been used as models of lipid membrane systems. The liposomes and aqueous linoleate micelles were irradiated in the presence of O 2 and N 2 O/O 2 (80/20 v/v). The peroxidation was initiated using gamma radiation from 60 Co radiation source and was monitored by measuring the increase in absorbance of conjugated diene at 232 nm and by the thiobarbituric acid (TBA) test. The oxidation products were also identified by GLC and GLC-MS analysis. (author)

  17. Analysis of radiation monitoring data by distribution-free statistical methods (a case of river system Techa-Iset'-Tobol-Irtysh contamination)

    Luneva, K.V.; Kryshev, A.I.; Nikitin, A.I.; Kryshev, I.I.

    2010-01-01

    The article presents the results of statistical analysis of radiation monitoring data of river system Techa-Iset'-Tobol-Irtysh contamination. A short description of analyzable data and the territory under consideration was given. The distribution-free statistic methods, used for comparative analysis, were described. Reasons of the methods selection and their application features were given. Comparative data analysis with traditional statistics methods was presented. Reliable decrease of 90 Sr specific activity in the river system object to object was determined, which is the evidence of the radionuclide transportation in the river system Techa-Iset'-Tobol-Irtysh [ru

  18. Radiation monitoring system for astronauts

    Thomson, I.; MacKay, G.; Ng, A.; Tomi, L.

    1996-01-01

    Astronauts in space are constantly under the bombardment of radiation particles from trapped electrons, and trapped proton. In addition, cosmic rays, while penetrating the spacecraft shell, generate secondary radiation of neutrons. As astronauts' stay in space is getting longer, the need for a real-time radiation monitoring device has become critical. Thermoluminescent dosemeter (TLD), used onboard both the MIR and the Space Transportation System (STS), cannot provide real-time dose reading. This paper describes a real-time direct read-out device, currently under development, which can measure skin, eye, and Blood Forming Organ (BFO) doses separately. (author)

  19. Survey and analysis of radiation safety management systems at medical institutions. Second report. Radiation measurement, calibration of radiation survey meters, and periodic check of installations, equipment, and protection instruments

    Ohba, Hisateru; Ogasawara, Katsuhiko; Aburano, Tamio

    2006-01-01

    We carried out a questionnaire survey to determine the actual situation of radiation safety management measures in all medical institutions in Japan that had nuclear medicine facilities. The questionnaire consisted of questions concerning the evaluation of shielding capacity; radiation measurement; periodic checks of installations, equipment, and protection instruments; and the calibration of radiation survey meters. The analysis was undertaken according to region, type of establishment, and number of beds. The overall response rate was 60 percent. For the evaluation of shielding capacity, the outsourcing rate was 53 percent of the total. For the radiation measurements of ''leakage radiation dose and radioactive contamination'' and contamination of radioactive substances in the air'', the outsourcing rates were 28 percent and 35 percent of the total, respectively (p<0.001, according to region and establishment). For the periodic check of radiation protection instruments, the implementation rate was 98 percent, and the outsourcing rate was 32 percent for radiation survey meters and 47 percent for lead aprons. The non-implemented rate for calibration of radiation survey meters was 25 percent of the total (p<0.001, according to region and establishment). The outsourcing rate for calibration of radiation survey meters accounted for 87 percent of the total, and of these medical institutions, 72 percent undertook annual calibration. The implementation rate for patient exposure measurement was 20 percent of the total (p<0.001, according to number of beds), and of these medical institutions 46 percent recorded measurement outcome. (author)

  20. Predictive analysis of the radiation exposure for the primary cooling system of the rated power operation of MONJU

    Matuo, Youichirou; Miyahara, Shinya; Hasegawa, Masanori; Maegawa, Yoshiharu

    2011-01-01

    Radioactive corrosion products (CP) are main source of personal radiation exposure during maintenance without fuel-failure accident in the Liquid-Metal Fast Breeder Reactor (LMFBR) plants. In order to establish the techniques of radiation dose estimation for personnel, program system 'DORE' has been developed. The DORE system is constructed by PSYCHE code and QAD code system. The density of each deposited CP of primary coolant system in MONJU was estimated by using the PSYCHE. Moreover, the QAD-CGGP2R code is applied to dose rate calculations for the primary coolant system in MONJU. The dose rate around primary piping system was visualized using AVS software. The predicted values were estimated to be saturated at 2-3 mSv/h in twenty years after the start of operation, and the dose rate reaches 4 mSv/h in domains near the IHX and the cold-leg piping. It has been assumed that the main radiation source is 54 Mn in the IHX, primary pump and cold-leg piping region. On the other hand, it was indicated that the contribution to dose rate of the 60 Co accounted for approximately 23% in the hot-leg piping region. (author)

  1. Analysis of radiation doses from operation of postulated commercial spent fuel transportation systems: Analysis of a system containing a monitored retrievable storage facility

    Smith, R.I.; Daling, P.M.; Faletti, D.W.

    1992-04-01

    This addendum report extends the original study of the estimated radiation doses to the public and to workers resulting from transporting spent nuclear fuel from commercial nuclear power reactor stations through the federal waste management system (FWMS), to a system that contains a monitored retrievable storage (MRS) facility. The system concepts and designs utilized herein are consistent with those used in the original study (circa 1985--1987). Because the FWMS design is still evolving, the results of these analyses may no longer apply to the design for casks and cask handling systems that are currently being considered. Four system scenarios are examined and compared with the reference No-MRS scenario (all spent fuel transported directly from the reactors to the western repository in standard-capacity truck and rail casks). In Scenarios 1 and 2, an MRS facility is located in eastern United States and ships either intact fuel assemblies or consolidated fuel rods and compacted assembly hardware in canisters. In Scenarios 3 and 4, an MRS facility is located in the western United States and ship either intact fuel assemblies or consolidated fuel rods and compacted assembly hardware in canisters

  2. Radiation detection system

    Riedel, Richard A [Knoxville, TN; Wintenberg, Alan L [Knoxville, TN; Clonts, Lloyd G [Knoxville, TN; Cooper, Ronald G [Oak Ridge, TN

    2012-02-14

    A preamplifier circuit for processing a signal provided by a radiation detector includes a transimpedance amplifier coupled to receive a current signal from a detector and generate a voltage signal at its output. A second amplification stage has an input coupled to an output of the transimpedance amplifier for providing an amplified voltage signal. Detector electronics include a preamplifier circuit having a first and second transimpedance amplifier coupled to receive a current signal from a first and second location on a detector, respectively, and generate a first and second voltage signal at respective outputs. A second amplification stage has an input coupled to an output of the transimpedance amplifiers for amplifying the first and said second voltage signals to provide first and second amplified voltage signals. A differential output stage is coupled to the second amplification stage for receiving the first and second amplified voltage signals and providing a pair of outputs from each of the first and second amplified voltage signals. Read out circuitry has an input coupled to receive both of the pair of outputs, the read out circuitry having structure for processing each of the pair of outputs, and providing a single digital output having a time-stamp therefrom.

  3. A study on quantitative analysis of field size and dose by using gating system in 4D conformal radiation treatment

    Ji, Youn-Sang; Dong, Kyung-Rae; Kim, Chang-Bok; Chung, Woon-Kwan; Cho, Jae-Hwan; Lee, Hae-Kag

    2012-10-01

    This study evaluated the gating-based 4-D conformal radiation therapy (4D-CT) treatment planning by a comparison with the common 3-D conformal radiation therapy (3D-CT) treatment planning and examined the change in treatment field size and dose to the tumors and adjacent normal tissues because an unnecessary dose is also included in the 3-D treatment planning for the radiation treatment of tumors in the chest and abdomen. The 3D-CT and gating-based 4D-CT images were obtained from patients who had undergone radiation treatment for chest and abdomen tumors in the oncology department. After establishing a treatment plan, the CT treatment and planning system were used to measure the change in field size for analysis. A dose volume histogram (DVH) was used to calculate the appropriate dose to planning target volume (PTV) tumors and adjacent normal tissue. The difference in the treatment volume of the chest was 0.6 and 0.83 cm on the X- and Y-axis, respectively, for the gross tumor volume (GTV). Accordingly, the values in the 4D-CT treatment planning were smaller and the dose was more concentrated by 2.7% and 0.9% on the GTV and clinical target volume (CTV), respectively. The normal tissues in the surrounding normal tissues were reduced by 3.0%, 7.2%, 0.4%, 1.7%, 2.6% and 0.2% in the bronchus, chest wall, esophagus, heart, lung and spinal cord, respectively. The difference in the treatment volume of the abdomen was 0.72 cm on the X-axis and 0.51 cm on the Y-axis for the GTV; and 1.06 cm on the X-axis and 1.85 cm on the Y-axis for the PTV. Therefore, the values in the 4D-CT treatment planning were smaller. The dose was concentrated by 6.8% and 4.3% on the GTV and PTV, respectively, whereas the adjacent normal tissues in the cord, Lt. kidney, Rt. kidney, small bowels and whole liver were reduced by 3.2%, 4.2%, 1.5%, 6.2% and 12.7%, respectively. The treatment field size was smaller in volume in the case of the 4D-CT treatment planning. In the DVH, the 4D-CT treatment

  4. Radiation exposure analysis of female nuclear medicine radiation workers

    Lee, Ju Young; Park, Hoon Hee

    2016-01-01

    In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus

  5. Radiation exposure analysis of female nuclear medicine radiation workers

    Lee, Ju Young [Dept. of Biomedical Engineering Graduate School, Chungbuk National University, Cheongju (Korea, Republic of); Park, Hoon Hee [Dept. of Radiological Technologist, Shingu College, Sungnam (Korea, Republic of)

    2016-06-15

    In this study, radiation workers who work in nuclear medicine department were analyzed to find the cause of differences of radiation exposure from General Characteristic, Knowledge, Recognition and Conduct, especially females working on nuclear medicine radiation, in order to pave the way for positive defense against radiation exposure. The subjects were 106 radiation workers who were divided into two groups of sixty-four males and forty-two females answered questions about their General Characteristic, Knowledge, Recognition, Conduct, and radiation exposure dose which was measured by TLD (Thermo Luminescence Dosimeter). The results of the analysis revealed that as the higher score of knowledge and conduct was shown, the radiation exposure decreased in female groups, and as the higher score of conduct was shown, the radiation exposure decreased in male groups. In the correlation analysis of female groups, the non-experienced in pregnancy showed decreasing amount of radiation exposure as the score of knowledge and conduct was higher and the experienced in pregnancy showed decreasing amount of radiation exposure as the score of recognition and conduct was higher. In the regression analysis on related factors of radiation exposure dose of nuclear medicine radiation workers, the gender caused the meaningful result and the amount of radiation exposure of female groups compared to male groups. In the regression analysis on related factors of radiation exposure dose of female groups, the factor of conduct showed a meaningful result and the amount of radiation exposure of the experienced in pregnancy was lower compared to the non-experienced. The conclusion of this study revealed that radiation exposure of female groups was lower than that of male groups. Therefore, male groups need to more actively defend themselves against radiation exposure. Among the female groups, the experienced in pregnancy who have an active defense tendency showed a lower radiation exposure. Thus

  6. Radiation Shielding Systems Using Nanotechnology

    Chen, Bin (Inventor); McKay, Christoper P. (Inventor)

    2011-01-01

    A system for shielding personnel and/or equipment from radiation particles. In one embodiment, a first substrate is connected to a first array or perpendicularly oriented metal-like fingers, and a second, electrically conducting substrate has an array of carbon nanostructure (CNS) fingers, coated with an electro-active polymer extending toward, but spaced apart from, the first substrate fingers. An electric current and electric charge discharge and dissipation system, connected to the second substrate, receives a current and/or voltage pulse initially generated when the first substrate receives incident radiation. In another embodiment, an array of CNSs is immersed in a first layer of hydrogen-rich polymers and in a second layer of metal-like material. In another embodiment, a one- or two-dimensional assembly of fibers containing CNSs embedded in a metal-like matrix serves as a radiation-protective fabric or body covering.

  7. Implementation and validation of a new fixation system for stereotactic radiation therapy: An analysis of patient immobilization.

    Lang, Stephanie; Linsenmeier, Claudia; Brown, Michelle L; Cavelaars, Frederique; Tini, Alessandra; Winter, Christopher; Krayenbuehl, Jerome

    2015-01-01

    Stereotactic radiation therapy is an established treatment technique for intracranial malignancies. We evaluated a new intracranial immobilization system with an emphasis on determining the intrafraction motion and the correlation of this motion with treatment time. Patients were immobilized using the trUpoint ARCH fixation system (CIVCO Medical Solutions). We collected data from 85 lesions in 73 patients treated between November 2011 and December 2013. Sixty-nine of 73 patients (95%) used the complete mask system; for the remaining 4 patients, the system had to be adapted. Patients were treated using volumetric modulated arc therapy stereotactic radiation therapy on a TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA). Fraction doses of 2-8 Gy were applied in 4-30 fractions. Daily cone beam computed tomography imaging was performed before the treatment and was matched to the reference computed tomography using a 6-degrees-of-freedom automatching procedure. Additionally, posttreatment cone beam computed tomography scans were performed to assess intrafraction motion for 67 patients (375 fractions). The average 3-dimensional setup error was 2.1 ± 2.9 mm. The mean pitch and roll was -0.1 ± 0.7° and 0.2 ± 0.7°. A total of 98.0% of the pitch values and 98.9% of the roll values were immobilization system appears to be robust in terms of setup accuracy, intrafraction motion, and repositioning of the mask system. Copyright © 2015 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.

  8. System integration for radiation records

    Lawson, B.J.; Farrell, L.; Meacham, C.; Tapio, J.

    1994-01-01

    System integration is the process where through networking and/or software development, necessary business information is available in a common computing environment. System integration is becoming an important objective for many businesses. System integration can improve productivity and efficiency, reduce redundant stored information and errors, and improve availability of information. This paper will discuss the information flow in a radiation health environment, and how system integration can help. Information handled includes external dosimetry and internal dosimetry. The paper will focus on an ORACLE based system integration software product

  9. Regulatory System of Radiation Protection in Taiwan

    Tang, F. T.; Huang, C. C.

    2004-01-01

    radiation sources until the discard of the radiation sources such that the competent authority can efficiently control. In order to control the moving status of high-activity sources, the AEC requires the owners of high-activity sources shall report the conditions of variation to the competent authority through Internet every month. According to the IRP Law the records of penalties shall also enter this system for statistical analysis so as to be used for regulatory reference. (Author)

  10. Deficiencies in radiation protection record systems

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system

  11. Deficiencies in radiation protection record systems

    Martin, J.B.; Lyon, M.

    1991-01-01

    Radiation protection records are a fundamental part of any program for protecting radiation workers. Records are essential to epidemiological studies of radiation workers and are becoming increasingly important as the number of radiation exposure litigation cases increases. Ready retrievability of comprehensive records is also essential to the adequate defense of a radiation protection program. Appraisals of numerous radiation protection programs have revealed that few record-keeping systems comply with American National Standards Institute, Standard Practice N13.6-1972. Record-keeping requirements and types of deficiencies in radiation protection records systems are presented in this paper, followed by general recommendations for implementing a comprehensive radiation protection records system. 8 refs

  12. Analysis of a control and data acquisition system for radiation protection monitors of spent fuel reprocessing plant

    Liu Boxue

    1997-01-01

    For the radiation protection monitoring of spent nuclear fuel reprocessing plant, the paper analyzes the composition and requirements of a control and data acquisition system. With the concepts of typical distributing and opening models, the hardware consists of IPC, communication of RS-485 bus lines and data multiplexer. The software consists of real-time multi-services operation system and modelling program. It can sample monitoring data, control monitor's operation, and process data and other information. It has good expansive and compatible features

  13. Conceptual development of a building-integrated photovoltaic–radiative cooling system and preliminary performance analysis in Eastern China

    Zhao, Bin; Hu, Mingke; Ao, Xianze; Pei, Gang

    2017-01-01

    Highlights: •A specific spectral characteristic for both PV and RC was proposed. •The PV/RC hybrid system based on spectral characteristic is original. •A thermal model of the system was established and the performance was analyzed. •The performance comparison with the conventional PV system was conducted. •The system shows considerable performance for both PV and RC. -- Abstract: Building-integrated photovoltaic/thermal (BIPV/T) technology has been receiving considerable research attention because of its ability to generate electricity and thermal energy simultaneously. However, space cooling is crucial for buildings in hot regions where space heating is of little use. This study proposed a building-integrated photovoltaic–radiative cooling system (BIPV–RC) that can generate electricity via photovoltaic (PV) conversion during daytime and generate cooling energy via radiative cooling (RC) during nighttime to satisfy the demand in such areas. The selective plate, which is the main component of the BIPV–RC system, exhibits high spectral absorptivity (emissivity) in the PV conversion band of crystalline silicon solar cells and in the atmospheric window band (i.e., 0.3–1.1 μm and 8–13 μm), as well as low spectral absorptivity (emissivity) in other bands. A quasi-steady-state mathematical model was built, and its performance under realistic ambient conditions was analyzed. The electrical efficiencies of the BIPV–RC and conventional BIPV systems were then compared under different solar radiations. Comparison results show that the annual electricity production and cooling energy gain of the BIPV–RC system in Hefei reached 156.74 kW h m −2 (equivalent to 564.26 MJ m −2 ) and 579.91 MJ m −2 , respectively. The total electricity production and cooling energy gain of this system are 96.96% higher than those of the BIPV system. Parametric studies show that the precipitable water vapor amount has remarkable effects on the nocturnal RC performance

  14. LANSCE radiation security system (RSS)

    Gallegos, F.R.

    1996-01-01

    The Radiation Security System (RSS) is an engineered safety system which automatically terminates transmission of accelerated ion beams in response to pre-defined abnormal conditions. It is one of the four major mechanisms used to protect people from radiation hazards induced by accelerated pulsed ion beams at the Los Alamos Neutron Science Center (LANSCE). The others are shielding, administrative policies and procedures, and qualified, trained personnel. Prompt radiation hazards at the half-mile long LANSCE accelerator exist due to average beam intensities ranging from 1 milli-amp for H + beam to 100 micro-amps for the high intensity H - beam. Experimental programs are supplied with variable energy (maximum 800 MeV), pulse-width (maximum 1 msec), and pulse frequency (maximum 120 Hz) ion beams. The RSS includes personnel access control systems, beam spill monitoring systems, and beam current level limiting systems. It is a stand-alone system with redundant logic chains. A fault of the RSS will cause the insertion of fusible beam plugs in the accelerator low energy beam transport. The design philosophy, description, and operation of the RSS are described in this paper

  15. Solid state radiation detector system

    1977-01-01

    A solid state radiation flux detector system utilizes a detector element, consisting of a bar of semiconductor having electrical conductance of magnitude dependent upon the magnitude of photon and charged particle flux impinging thereon, and negative feedback circuitry for adjusting the current flow through a light emitting diode to facilitate the addition of optical flux, having a magnitude decreasing in proportion to any increase in the magnitude of radiation (e.g. x-ray) flux incident upon the detector element, whereby the conductance of the detector element is maintained essentially constant. The light emitting diode also illuminates a photodiode to generate a detector output having a stable, highly linear response with time and incident radiation flux changes

  16. Radiachromic: a radiation monitoring system

    Humpherys, K.C.; Kantz, A.D.

    1977-01-01

    Various plastic film materials have been utilized to measure radiation fields. The radiachromic materials have been found to have advantages in reproducibility, stability, equivalent response to electrons and gamma ray fields, dose rate dependence and negligible variation for most environmental parameters. A simple photometer has been developed for read-out. The physical and chemical properties of the total system are described. A standard radiachromic has been selected for application to radiation processing. This material has a dose range of 5 x 10 4 to 3 x 10 7 rads, no dose rate effects to above 4 x 10 14 R/sec, an equivalent response to electrons and gamma rays, shelf life of greater than one year. Other forms are also applicable to radiation processing. (author)

  17. Rational system of radiation dosimetry

    Katoh, K.; Tada, J.

    1996-01-01

    Radiation doses are the most important subject to the sciences relating to the effects of ionizing radiation on matter. Since any science at all must stand on the quantitative description of causality, uses of physical quantities as the measures are indispensable. The current system of radiation dosimetry is built on the fundamental dose of the absorbed dose, which is defined as the 'energy imparted' density, and for practical convenience various weighted absorbed doses are introduced as subsidiary. However, it has been pointed out that these quantities lack adequacy inherently as a measure of causes, in addition to the insufficiency of the specification of the concept. Firstly, separation of the quantities of radiation field and of the dose is not possible, since both quantities are deeply related to the same microscopic constituents, i.e., electrons. Secondly, the value of the absorbed dose cannot be fixed at the moment of irradiation. Since the absorbed dose is a quantity of interaction product of radiation and matter, the values of the dose cannot be fixed instantaneously. Thirdly, it is not easy to envision the physical entity of the quantity from the definition. The form of existence of the 'imparted' energy is not clear in the current definition. These defects can not be removed as long as an interaction product is adopted as the dose quantity. In this paper, the authors present a prescription to solve these problems. (author)

  18. Radiation-hardened control system

    Vandermolen, R.I.; Smith, S.F.; Emery, M.S.

    1993-01-01

    A radiation-hardened bit-slice control system with associated input/output circuits was developed to prove that programmable circuits could be constructed to successfully implement intelligent functions in a highly radioactive environment. The goal for this effort was to design and test a programmable control system that could withstand a minimum total dose of 10 7 rads (gamma). The Radiation Hardened Control System (RHCS) was tested in operation at a dose rate that ranged up to 135 krad/h, with an average total dose of 10.75 Mrads. Further testing beyond the required 10 7 rads was also conducted. RHCS performed properly through the target dose of 10 7 rads, and sporadic intermittent failures in some programmable logic devices were noted after ∼ 13 Mrads

  19. Maintenance of radiation safety information system

    Choi, Ho Sun [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of); Park, Moon Il; Chung, Chong Kyu; Lim, Bock Soo; Kim, Hyung Uk; Chang, Kwang Il; Nam, Kwan Hyun; Cho, Hye Ryan [AD center incubation LAB, Taejon (Korea, Republic of)

    2001-12-15

    The objectives of radiation safety information system maintenance are to maintain the requirement of users, change of job process and upgrade of the system performance stably and effectively while system maintenance. We conduct the code of conduct recommended by IAEA, management of radioisotope inventory database systematically using analysis for the state of inventory database integrated in this system. This system and database will be support the regulatory guidance, rule making and information to the MOST, KINS, other regulatory related organization and general public optimizationally.

  20. Nuclear analysis methods. Rudiments of radiation protection

    Roth, E.

    1998-01-01

    The nuclear analysis methods are generally used to analyse radioactive elements but they can be used also for chemical analysis, with fields such analysis and characterization of traces. The principles of radiation protection are explained (ALARA), the biological effects of ionizing radiations are given, elements and units used in radiation protection are reminded in tables. A part of this article is devoted to how to use radiation protection in a nuclear analysis laboratory. (N.C.)

  1. The design of radiation monitor passageway system

    Chu Chengsheng

    2006-10-01

    The Radiation Monitor Passageway System is designed as four modules, the radiation detection modules, the control modules, the mechanism modules and the optional modules. this system integrate the radiation detection technology and door ban control technology. It is a effective radiation monitor equipment with high detect sensitiveness, it will be hopeful devoted to national nuclear safeguard. (authors)

  2. The effects of radiation on electronic systems

    Messenger, G.C.; Ash, M.S.

    1986-01-01

    This book is the first unified treatment of the analysis and design methods for protection of principally electronic systems from the deleterious effects of nuclear and electro-magnetic radiation. Coverage spans from a detailed description of the nuclear radiation sources to pertinent semiconductor physics, then to hardness assurance. This work combines the disciplines of solid state physics, semiconductor physics, circuit engineering, nuclear physics, together with electronics and electromagnetic theory into a book that can be used as a text with problems at the end of the majority of the chapters. Written by veterans in the field, the most significant feature of this book is its comprehensive treatment of the phenomena involved. This treatment includes the analysis and design of the effect of nuclear radiation on electronic systems from the experimental, theoretical, and engineering viewpoints. Unique pedagogical attempts are employed to make the material more understandable from the position of an enlightened engineering and scientific readership whose task is the design and analysis of radiation hardened electronic systems

  3. Distributed radiation protection console system

    Chhokra, R.S.; Deshpande, V.K.; Mishra, H.; Rajeev, K.P.; Thakur, Bipla B.; Munj, Niket

    2004-01-01

    Radiation exposure control is one of the most important aspects in any nuclear facility . It encompasses continuous monitoring of the various areas of the facility to detect any increase in the radiation level and/or the air activity level beyond preset limits and alarm the O and M personnel working in these areas. Detection and measurement of radiation level and the air activity level is carried out by a number of monitors installed in the areas. These monitors include Area Gamma Monitors, Continuous Air Monitors, Pu-In-Air Monitors, Criticality Monitors etc. Traditionally, these measurements are displayed and recorded on a Central Radiation Protection Console(CRPC), which is located in the central control room of the facility. This methodology suffers from the shortcoming that any worker required to enter a work area will have to inquire about the radiation status of the area either from the CRPC or will get to know the same directly from the installed only after entering the area. This shortcoming can lead to avoidable delays in attending to the work or to unwanted exposure. The authors have designed and developed a system called Distributed Radiation Protection Console (DRPC) to overcome this shortcoming. A DRPC is a console which is located outside the entrance of a given area and displays the radiation status of the area. It presents to health physicist and the plant operators a graphic over-view of the radiation and air activity levels in the particular area of the plant. It also provides audio visual annunciation of the alarm status. Each radioactive area in a nuclear facility will have its own DRPC, which will receive as its inputs the analog and digital signals from radiation monitoring instruments installed in the area and would not only show those readings on its video graphic screen but will also provide warning messages and instructions to the personnel entering the active areas. The various DRPCs can be integrated into a Local Area Network, where the

  4. Radiation-induced functional damages in the regeneration system for the gastrointestinal epithelium cell and analysis of its nutritional modification

    Yamada, Kazuhiko; Narita, Mayumi; Ogawa, Yuko; Shinohara, Kiyoko; Nakazawa, Yukiko; Yamada, Keiko [National Inst. of Health and Nutrition, Tokyo (Japan)

    2000-02-01

    It has been known that the stem cells of villus-crypt zone are highly sensitive to radiation exposure. In this study, radiation-induced damages in gastrointestinal cell regeneration system were investigated from an aspect of nutritional factors to clarify the damages in digestive functions caused by X-ray exposure and recovery from them. The activities of digestive enzymes in the small intestine after in vivo X-ray exposure at 100 Gy were determined. The sucrose activity in the upper intestine was gradually reduced to about a half 3 days after the exposure. This change pattern of activity was also observed in other regions in the intestine. This tendency was similar to that of trehalase activity, but the changes in alkaline phosphatase and leucine amino-peptidase activities were less than the above two enzymes. Therefore, time course changes of sucrose and trehalase pattern in the villus-crypt zone were monitored after radiation exposure. Either of the two enzyme activities was low in the crypt and gradually increased from the basement of villus to its top. These activities were dose-dependently reduced by X-ray exposure. Especially it was marked for trehalose activity. Moreover, the amounts of short-chain fatty acids such as acetic acid, propionic acid, butylic acid in the cecum were determined. Significant increases in acetic acid and propionic acid contents were fount at 1 or 2 days after the X-ray exposure. These increases in fatty acids contents were more distinctive in the animals that received forced and free administration of food than those that received free administration alone. The presence of food components in the intestine might be effective for protecting the mucous membrane regeneration from radiation exposure. (M.N.)

  5. 21 CFR 892.5300 - Medical neutron radiation therapy system.

    2010-04-01

    ... therapy system. (a) Identification. A medical neutron radiation therapy system is a device intended to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Medical neutron radiation therapy system. 892.5300... analysis and display equipment, patient and equipment support, treatment planning computer programs...

  6. 21 CFR 892.5750 - Radionuclide radiation therapy system.

    2010-04-01

    ... system. (a) Identification. A radionuclide radiation therapy system is a device intended to permit an... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radionuclide radiation therapy system. 892.5750... patient's body. This generic type of device may include signal analysis and display equipment, patient and...

  7. High power radiation guiding systems for laser driven accelerators

    Cutolo, A.

    1985-01-01

    This paper reviews the main problems encountered in the design of an optical system for transmitting high fluence radiation in a laser driven accelerator. Particular attention is devoted to the analysis of mirror and waveguide systems. (orig.)

  8. Distributed hierarchical radiation monitoring system

    Barak, D.

    1985-01-01

    A solution to the problem of monitoring the radiation levels in and around a nuclear facility is presented in this paper. This is a private case of a large scale general purpose data acqisition system with high reliability, availability and short maintenance time. The physical layout of the detectors in the plant, and the strict control demands dictated a distributed and hierarchical system. The system is comprised of three levels, each level contains modules. Level one contains the Control modules which collects data from groups of detectors and executes emergency local control tasks. In level two are the Group controllers which concentrate data from the Control modules, and enable local display and communication. The system computer is in level three, enabling the plant operator to receive information from the detectors and execute control tasks. The described system was built and is operating successfully for about two years. (author)

  9. Analysis of the power system from an electron beam accelerator and the correlation with the theoretical dosimetry for radiation processing

    Somessari, Samir Luiz; Somessari, Elizabeth S. Ribeiro; Silveira, Carlos Gaia da; Calvo, Wilson Aparecido Parejo, E-mail: somessar@ipen.br, E-mail: esomessa@ipen.br, E-mail: cgsilvei@ipen.br, E-mail: wapcalvo@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2013-07-01

    Dynamitron DC1500/25/04 type electron beam accelerator (EBA), model JOB 188, was manufactured by IBA Industrial (Radiation Dynamics, Inc.) and installed at IPEN/CNEN-SP in 1978. The technical specifications of the EBA are: energy 0.5 to 1.5 MeV; beam current: 0.3 to 25.0 mA; beam scanning: 60 to 120 cm; beam width: 25.4 mm and frequency: 100 Hz. Nowadays, this accelerator has been used for innumerable applications, such as: for sterilization of medical, pharmaceutical and biological products; treatment of industrial and domestic effluents and sludge; preservation and disinfestation of foods and agricultural products; lignocellulosic material irradiation as a pre-treatment to produce ethanol bio-fuel; decontamination of pesticide packing; solid residues remediation; organic compounds removal from wastewater; treatment of effluent from petroleum production units; crosslinking of foams, wires and electric cables; composite and nanocomposite materials and carbon fibers irradiation; irradiated grafting ion-exchange membranes for fuel cells application; natural polymers and multilayer packages irradiation, and biodegradable blends production. The energy of the electron beam is calculated as a function of the current in the accelerator high-voltage divisor, taking into account the thickness and density of the material to be irradiated. This energy is calculated considering the electron through the entire material and the distance from the titanium foil window, so that the absorbed doses at the point of entrance and exit are equivalent on the material. The dose is directly proportional to the beam current and the exposure time of the material under the electron beam and inversely proportional to the scan width. The aim of this paper is to analyze the power system parameters of the EBA Dynamitron DC1500/25/04 accelerator, such as, voltage and root-mean-square (RMS) current in the oscillator system, high voltage generator and waveform, using software developed in the

  10. Analysis of the power system from an electron beam accelerator and the correlation with the theoretical dosimetry for radiation processing

    Somessari, Samir Luiz; Somessari, Elizabeth S. Ribeiro; Silveira, Carlos Gaia da; Calvo, Wilson Aparecido Parejo

    2013-01-01

    Dynamitron DC1500/25/04 type electron beam accelerator (EBA), model JOB 188, was manufactured by IBA Industrial (Radiation Dynamics, Inc.) and installed at IPEN/CNEN-SP in 1978. The technical specifications of the EBA are: energy 0.5 to 1.5 MeV; beam current: 0.3 to 25.0 mA; beam scanning: 60 to 120 cm; beam width: 25.4 mm and frequency: 100 Hz. Nowadays, this accelerator has been used for innumerable applications, such as: for sterilization of medical, pharmaceutical and biological products; treatment of industrial and domestic effluents and sludge; preservation and disinfestation of foods and agricultural products; lignocellulosic material irradiation as a pre-treatment to produce ethanol bio-fuel; decontamination of pesticide packing; solid residues remediation; organic compounds removal from wastewater; treatment of effluent from petroleum production units; crosslinking of foams, wires and electric cables; composite and nanocomposite materials and carbon fibers irradiation; irradiated grafting ion-exchange membranes for fuel cells application; natural polymers and multilayer packages irradiation, and biodegradable blends production. The energy of the electron beam is calculated as a function of the current in the accelerator high-voltage divisor, taking into account the thickness and density of the material to be irradiated. This energy is calculated considering the electron through the entire material and the distance from the titanium foil window, so that the absorbed doses at the point of entrance and exit are equivalent on the material. The dose is directly proportional to the beam current and the exposure time of the material under the electron beam and inversely proportional to the scan width. The aim of this paper is to analyze the power system parameters of the EBA Dynamitron DC1500/25/04 accelerator, such as, voltage and root-mean-square (RMS) current in the oscillator system, high voltage generator and waveform, using software developed in the

  11. The radiation metrology network related to the field of mammography: implementation and uncertainty analysis of the calibration system

    Peixoto, J. G. P.; de Almeida, C. E.

    2001-09-01

    It is recognized by the international guidelines that it is necessary to offer calibration services for mammography beams in order to improve the quality of clinical diagnosis. Major efforts have been made by several laboratories in order to establish an appropriate and traceable calibration infrastructure and to provide the basis for a quality control programme in mammography. The contribution of the radiation metrology network to the users of mammography is reviewed in this work. Also steps required for the implementation of a mammography calibration system using a constant potential x-ray and a clinical mammography x-ray machine are presented. The various qualities of mammography radiation discussed in this work are in accordance with the IEC 61674 and the AAPM recommendations. They are at present available at several primary standard dosimetry laboratories (PSDLs), namely the PTB, NIST and BEV and a few secondary standard dosimetry laboratories (SSDLs) such as at the University of Wisconsin and at the IAEA's SSDL. We discuss the uncertainties involved in all steps of the calibration chain in accord with the ISO recommendations.

  12. A microprocessor based mobile radiation survey system

    Gilbert, R.W.; McCormack, W.D.

    1984-01-01

    A microprocessor-based system has been designed and constructed to enhance the performance of routine radiation surveys on roads within the Hanford site. This device continually monitors system performance and output from four sodium iodide detectors mounted on the rear bumper of a 4-wheel drive truck. The gamma radiation count rate in counts-per-second is monitored, and a running average computed, with the results compared to predefined limits. If an abnormal instantaneous or average count rate is detected, an alarm is sounded with responsible data displayed on a liquid crystal panel in the cab of the vehicle. The system also has the capability to evaluate detector output using multiple time constants and to perform more complex tests and comparison of the data. Data can be archived for later analysis on conventional chart recorders or stored in digital form on magnetic tape or other digital storage media

  13. Microprocessor based mobile radiation survey system

    Gilbert, R.W.; McCormack, W.D.

    1983-12-01

    A microprocessor-based system has been designed and constructed to enhance the performance of routine radiation surveys on roads within the Hanford site. This device continually monitors system performance and output from four sodium iodide detectors mounted on the rear bumper of a 4-wheel drive truck. The gamma radiation count rate in counts-per-second is monitored, and a running average computed, with the results compared to predefined limits. If an abnormal instantaneous or average count rate is detected, an alarm is sounded with responsible data displayed on a liquid crystal panel in the cab of the vehicle. The system also has the capability to evaluate detector output using multiple time constants and to perform more complex tests and comparison of the data. Data can be archived for later analysis on conventional chart recorders or stored in digital form on magnetic tape or other digital storage media. 4 figures

  14. Radiation injury to the nervous system

    Gutin, P.H.; Leibel, S.A.; Sneline, G.E.

    1991-01-01

    This book is designed to describe to the radiation biologist, radiation oncologist, neurologist, neurosurgeon, medical oncologist, and neuro-oncologist, the current state of knowledge about the tolerance of the nervous system to various kinds of radiation, the mechanisms of radiation injury, and how nervous system tolerance and injury are related to the more general problem of radiation damage to normal tissue of all types. The information collected here should stimulate interest in and facilitate the growing research effort into radiation injury to the nervous system

  15. Monitoring and crisis system of radiation safety

    Bartok, J.; Borovansky, P.; Macica, J.; Petrovicova, M.

    2005-01-01

    In this paper we have briefly described our practical experiences with the most complex Radiation Monitoring System we have designed. This system consists of number of stations; those data are collected in the main crisis center of the whole system. The main center integrates RMS Central Database, the IMS Model Suite workstation and the Graphics workstation. The radiations probes of the RP series are the base for stationary , portable sets and for sets measuring underwater radiation. The radiation and meteorological data, which are necessary for reasonable interpretation of radiation data, are archived in RMS Central database. The Lagrangian trajectory model from the IMS Model Suite serves for radiation dispersion modeling. (authors)

  16. Uzbekistan Radiation Portal Monitoring System

    Richardson, J; Knapp, R; Loshak, A; Yuldashev, B; Petrenko, V

    2005-01-01

    The work proposed in this presentation builds on the foundation set by the DTRA funded demonstration project begun in 2000 and completed in December of 2003. This previous work consisted of two phases whose overall objective was to install portal radiation monitors at four select ports-of-entry in Uzbekistan (Tashkent International Airport, Gisht-Kuprik (Kazakhstan border), Alat (Turkmenistan border), and Termez (Afghanistan border)) in order to demonstrate their effectiveness in preventing the illicit trafficking of nuclear materials. The objectives also included developing and demonstrating capabilities in the design, installation, operation, training, and maintenance of a radiation portal monitoring system. The system and demonstration project has proved successful in many ways. An effective working relationship among the Uzbekistan Customs Services, Uzbekistan Border Guards, and Uzbekistan Institute of Nuclear Physics has been developed. There has been unprecedented openness with the sharing of portal monitor data with Lawrence Livermore National Laboratory. The system has proved to be effective, with detection of illicit trafficking, and, at Alat, an arrest of three persons illegally transporting radioactive materials into Turkmenistan. The demonstration project has made Uzbekistan a model nonproliferation state in Central Asia and, with an expanded program, places them in a position to seal a likely transit route for illicit nuclear materials. These results will be described. In addition, this work is currently being expanded to include additional ports-of-entry in Uzbekistan. The process for deciding on which additional ports-of-entry to equip will also be described

  17. A unique radiation area monitoring system

    Murphy, P.C.; Allen, G.C.

    1978-01-01

    The Remote Area Monitoring Systems (RAMS) monitors four radiation areas with two independent systems in each area. Each system consists of power supplies, four ionization chambers, and four analog and digital circuits. The first system controls the warning beacons, horns, annunciation panel and interlocks. The second system presents a quantitative dose rate indication at the console and in the radiation area

  18. Workplace analysis and radiation protection

    Le Guen, B.; Bosquet, Ph.; Chevillard, S.; Gauron, Ch.; Lallemand, J.; Lombard, J.; Menetrier, F.; Feuardent, J.; Maccia, C.; Donadille, L.; Rehel, J.L.; Donnarieix, D.; Garrigou, A.; Gauthereau, V.; Truchi, F.; Chardin, J.; Debouck, F.; Clairand, I.; Amabile, J.Ch.; Vrigneaud, J.M.; Roussille, F.; Witschger, O.; Feuardent, J.; Scanff, P.; Rannou, A.

    2010-01-01

    This document gathers the slides of the available presentations given during this conference day. Fifteen presentations out of 16 are assembled in the document and deal with: 1 - the evolution of doses received by workers (J. Feuardent); 2 - evaluation of extremities dosimetry among interventional radiology practitioners (L. Donadille); 3 - practical guide for the realisation of workplace dosimetry studies presenting a ionizing radiation exposure risk: and example in nuclear medicine (J.L. Rehel); 4 - workplace studies in radiotherapy-curietherapy (D. Donnarieix); 5 - from dosimetry to physical intensity: the case of heat insulation activities (A. Garrigou and C. Piccadaci); 6 - the consideration of human factor during facility modifications (V. Gauthereau); 7 - how to carry out a workplace analysis in gamma-graphy? (F. Truchi); 8 - workplace studies in the framework of dismantling activities (J. Chardin); 9 - team synergy (F. Debouck); 10 - adaptation of individual dosimetry to the workplace: the case of external exposure (I. Clairand); 11 - technical aspects of the evaluation of ionizing radiations exposure induced by a new interventional radiology procedure (J.C. Amabile); 12 - the point of view of a radioprotection skilled person in a nuclear medicine service (J.M. Vrigneaud); 13 - workplace studies for the unique document (F. Roussille); 14 - occupational exposure to manufactured nano-particles: issues and knowledge status (O. Witschger); 15 - toxicological risk of nano-particles: 'health impact'? (S. Chevillard). (J.S.)

  19. Available computer codes and data for radiation transport analysis

    Trubey, D.K.; Maskewitz, B.F.; Roussin, R.W.

    1975-01-01

    The Radiation Shielding Information Center (RSIC), sponsored and supported by the Energy Research and Development Administration (ERDA) and the Defense Nuclear Agency (DNA), is a technical institute serving the radiation transport and shielding community. It acquires, selects, stores, retrieves, evaluates, analyzes, synthesizes, and disseminates information on shielding and ionizing radiation transport. The major activities include: (1) operating a computer-based information system and answering inquiries on radiation analysis, (2) collecting, checking out, packaging, and distributing large computer codes, and evaluated and processed data libraries. The data packages include multigroup coupled neutron-gamma-ray cross sections and kerma coefficients, other nuclear data, and radiation transport benchmark problem results

  20. RESPONSE OF THE GREEK EARLY WARNING SYSTEM REUTER-STOKES IONIZATION CHAMBERS TO TERRESTRIAL AND COSMIC RADIATION EVALUATED IN COMPARISON WITH SPECTROSCOPIC DATA AND TIME SERIES ANALYSIS.

    Leontaris, F; Clouvas, A; Xanthos, S; Maltezos, A; Potiriadis, C; Kiriakopoulos, E; Guilhot, J

    2018-02-01

    The Telemetric Early Warning System Network of the Greek Atomic Energy Commission consists mainly of a network of 24 Reuter-Stokes high-pressure ionization chambers (HPIC) for gamma dose rate measurements and covers all Greece. In the present work, the response of the Reuter-Stokes HPIC to terrestrial and cosmic radiation was evaluated in comparison with spectroscopic data obtained by in situ gamma spectrometry measurements with portable hyper pure Germanium detectors (HPGe), near the Reuter-Stokes detectors and time series analysis. For the HPIC detectors, a conversion factor for the measured absorbed dose rate in air (in nGy h-1) to the total ambient dose equivalent rate Ḣ*(10), due to terrestrial and cosmic component, was deduced by the field measurements. Time series analysis of the mean monthly dose rate (measured by the Reuter-Stokes detector in Thessaloniki, northern Greece, from 2001 to 2016) was performed with advanced statistical methods (Fast Fourier Analysis and Zhao Atlas Marks Transform). Fourier analysis reveals several periodicities (periodogram). The periodogram of the absorbed dose rate in air values was compared with the periodogram of the values measured for the same period (2001-16) and in the same location with a NaI (Tl) detector which in principle is not sensitive to cosmic radiation. The obtained results are presented and discussed. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  1. Radiographic imaging system for high energy radiation

    1975-01-01

    A radiographic imaging system for high energy radiation is described utilizing a detector of such radiation and a mask having regions relatively transparent to such radiation and interspersed among regions relatively opaque to such radiation. A relative motion is imparted between the mask and the detector, the detector providing a time varying signal in response to the incident radiation and in response to the relative motion. The time varying signal provides, with the aid of a decoder, an image of a source of such radiation

  2. Radiographic imaging system for high energy radiation

    Barrett, H.H.

    1976-01-01

    A radiographic imaging system for high energy radiation utilizing a detector of such radiation and a mask having regions relatively transparent to such radiation interspersed among regions relatively opaque to such radiation is described. A relative motion is imparted between the mask and the detector, the detector providing a time varying signal in response to the incident radiation and in response to the relative motion. The time varying signal provides, with the aid of a decoder, an image of a source of such radiation

  3. Development trend of radiation biology research-systems radiation biology

    Min Rui

    2010-01-01

    Radiation biology research has past 80 years. We have known much more about fundamentals, processes and results of biology effects induced by radiation and various factors that influence biology effects wide and deep, however many old and new scientific problems occurring in the field of radiation biology research remain to be illustrated. To explore and figure these scientific problems need systemic concept, methods and multi dimension view on the base of considerations of complexity of biology system, diversity of biology response, temporal and spatial process of biological effects during occurrence, and complex feed back network of biological regulations. (authors)

  4. Coherent Radiation in Atomic Systems

    Sutherland, Robert Tyler

    Over the last century, quantum mechanics has dramatically altered our understanding of light and matter. Impressively, exploring the relationship between the two continues to provide important insights into the physics of many-body systems. In this thesis, we add to this still growing field of study. Specifically, we discuss superradiant line-broadening and cooperative dipole-dipole interactions for cold atom clouds in the linear-optics regime. We then discuss how coherent radiation changes both the photon scattering properties and the excitation distribution of atomic arrays. After that, we explore the nature of superradiance in initially inverted clouds of multi-level atoms. Finally, we explore the physics of clouds with degenerate Zeeman ground states, and show that this creates quantum effects that fundamentally change the photon scattering of atomic ensembles.

  5. Radiobiology of systemic radiation therapy.

    Murray, David; McEwan, Alexander J

    2007-02-01

    Although systemic radionuclide therapy (SRT) is effective as a palliative therapy in patients with metastatic cancer, there has been limited success in expanding patterns of utilization and in bringing novel systemic radiotherapeutic agents to routine clinical use. Although there are many factors that contribute to this situation, we hypothesize that a better understanding of the radiobiology and mechanism of action of SRT will facilitate the development of future compounds and the future designs of prospective clinical trials. If these trials can be rationalized to the biological basis of the therapy, it is likely that the long-term outcome would be enhanced therapeutic efficacy. In this review, we provide perspectives of the current state of low-dose-rate (LDR) radiation research and offer linkages where appropriate with current clinical knowledge. These include the recently described phenomena of low-dose hyper-radiosensitivity-increased radioresistance (LDH-IRR), adaptive responses, and biological bystander effects. Each of these areas require a major reconsideration of existing models for radiation action and an understanding of how this knowledge will integrate into the evolution of clinical SRT practice. Validation of a role in vivo for both LDH-IRR and biological bystander effects in SRT would greatly impact the way we would assess therapeutic response to SRT, the design of clinical trials of novel SRT radiopharmaceuticals, and risk estimates for both therapeutic and diagnostic radiopharmaceuticals. We believe that the current state of research in LDR effects offers a major opportunity to the nuclear medicine community to address the basic science of clinical SRT practice, to use this new knowledge to expand the use and roles of SRT, and to facilitate the introduction of new therapeutic radiopharmaceuticals.

  6. Analysis of n-in-p type silicon detectors for high radiation environment with fast analogue and binary readout systems

    Printz, Martin

    2016-01-22

    The Large Hadron Collider at CERN is the most powerful particle accelerator ever built. The collision of high intensity proton beams at a center of mass energy of up to 14 TeV allows the exploration of the undiscovered territory at the TeV scale with great detail. The high energy physics frontier covers detailed Standard Model (SM) physics like the search for the SM Higgs boson which has been found in July 2012 but also physics beyond the SM like the Supersymmetry or studies of the quark-gluon plasma. The production rate of certain events is correlated to the instantaneous luminosity which is a measure for the number of detected events with in a certain time with respect to the interaction cross-section. In order to increase the statistics by collecting more data the integrated luminosity is maximized as far as possible. Simultaneously an increase of the particle energy and the luminosity reveals challenging experimental requirements for the trigger and detector systems present at the LHC. After a successful Run 1 of the machine between 2010 and 2013, the energy and the instantaneous luminosity of the machine are sequentially increased up to the last so called Phase II Upgrade planned for the years 2024 and 2025. The high luminosity LHC will provide particle beams with the final 14 TeV center of mass energy at an instantaneous luminosity of 5 x 10{sup 34} cm{sup -2}s{sup -1} which is five to seven times the nominal design luminosity. In the course of the Upgrade, the experiments will face extraordinary radiation environments and particle densities and have to be upgraded as well in order to cope with the challenging demands. The Compact Muon Solenoid (CMS) at CERN is a general purpose experiment with a diverse physics measurement program. It is built of several subdetectors. The most inner part consists of the pixel detector and the silicon strip tracker. The latter will be replaced completely during the Phase II Upgrade by a new layout whereas a different silicon

  7. Radiation protection technician job task analysis manual

    1990-03-01

    This manual was developed to assist all DOE contractors in the design and conduct of job task analysis (JTA) for the radiation protection technician. Experience throughout the nuclear industry and the DOE system has indicated that the quality and efficiency in conducting a JTA at most sites is greatly enhanced by using a generic task list for the position, and clearly written guidelines on the JTA process. This manual is designed to provide this information for personnel to use in developing and conducting site-specific JTAs. (VC)

  8. Radiation safety systems at the NSLS

    Dickinson, T.

    1987-04-01

    This report describes design principles that were used to establish the radiation safety systems at the National Synchrotron Light Source. The author described existing safety systems and the history of partial system failures. 1 fig

  9. Hybrid Active-Passive Radiation Shielding System

    National Aeronautics and Space Administration — A radiation shielding system is proposed that integrates active magnetic fields with passive shielding materials. The objective is to increase the shielding...

  10. Radiation damage in biomolecular systems

    Fuss, Martina Christina

    2012-01-01

    Since the discovery of X-rays and radioactivity, ionizing radiations have been widely applied in medicine both for diagnostic and therapeutic purposes. The risks associated with radiation exposure and handling led to the parallel development of the field of radiation protection. Pioneering experiments done by Sanche and co-workers in 2000 showed that low-energy secondary electrons, which are abundantly generated along radiation tracks, are primarily responsible for radiation damage through successive interactions with the molecular constituents of the medium. Apart from ionizing processes, which are usually related to radiation damage, below the ionization level low-energy electrons can induce molecular fragmentation via dissociative processes such as internal excitation and electron attachment. This prompted collaborative projects between different research groups from European countries together with other specialists from Canada,  the USA and Australia. This book summarizes the advances achieved by these...

  11. Electromechanically cooled germanium radiation detector system

    Lavietes, Anthony D.; Joseph Mauger, G.; Anderson, Eric H.

    1999-01-01

    We have successfully developed and fielded an electromechanically cooled germanium radiation detector (EMC-HPGe) at Lawrence Livermore National Laboratory (LLNL). This detector system was designed to provide optimum energy resolution, long lifetime, and extremely reliable operation for unattended and portable applications. For most analytical applications, high purity germanium (HPGe) detectors are the standard detectors of choice, providing an unsurpassed combination of high energy resolution performance and exceptional detection efficiency. Logistical difficulties associated with providing the required liquid nitrogen (LN) for cooling is the primary reason that these systems are found mainly in laboratories. The EMC-HPGe detector system described in this paper successfully provides HPGe detector performance in a portable instrument that allows for isotopic analysis in the field. It incorporates a unique active vibration control system that allows the use of a Sunpower Stirling cycle cryocooler unit without significant spectral degradation from microphonics. All standard isotopic analysis codes, including MGA and MGA++, GAMANL, GRPANL and MGAU, typically used with HPGe detectors can be used with this system with excellent results. Several national and international Safeguards organisations including the International Atomic Energy Agency (IAEA) and U.S. Department of Energy (DOE) have expressed interest in this system. The detector was combined with custom software and demonstrated as a rapid Field Radiometric Identification System (FRIS) for the U.S. Customs Service . The European Communities' Safeguards Directorate (EURATOM) is field-testing the first Safeguards prototype in their applications. The EMC-HPGe detector system design, recent applications, and results will be highlighted

  12. Computer-controlled radiation monitoring system

    Homann, S.G.

    1994-01-01

    A computer-controlled radiation monitoring system was designed and installed at the Lawrence Livermore National Laboratory's Multiuser Tandem Laboratory (10 MV tandem accelerator from High Voltage Engineering Corporation). The system continuously monitors the photon and neutron radiation environment associated with the facility and automatically suspends accelerator operation if preset radiation levels are exceeded. The system has proved reliable real-time radiation monitoring over the past five years, and has been a valuable tool for maintaining personnel exposure as low as reasonably achievable

  13. A new radiation exposure record system

    Lyon, M.; Berndt, V.L.; Trevino, G.W.; Oakley, B.M.

    1993-04-01

    The Hanford Radiological Records Program (HRRP) serves all Hanford contractors as the single repository for radiological exposure for all Hanford employees, subcontractors, and visitors. The program administers and preserves all Hanford radiation exposure records. The program also maintains a Radiation Protection Historical File which is a historical file of Hanford radiation protection and dosimetry procedures and practices. Several years ago DOE declared the existing UNIVAC mainframe computer obsolete and the existing Occupational Radiation Exposure (ORE) system was slated to be redeveloped. The new system named the Radiological Exposure (REX) System is described in this document

  14. Risk analysis of external radiation therapy

    Arvidsson, Marcus

    2011-09-01

    External radiation therapy is carried out via a complex treatment process in which many different groups of staff work together. Much of the work is dependent on and in collaboration with advanced technical equipment. The purpose of the research task has been to identify a process for external radiation therapy and to identify, test and analyze a suitable method for performing risk analysis of external radiation therapy

  15. Debris prevention system, radiation system, and lithograpic apparatus

    2009-01-01

    A debris prevention system is constructed and arranged to prevent debris that emanates from a radiation source from propagating with radiation from the radiation source into or within a lithographic apparatus. The debris prevention system includes an aperture that defines a maximum emission angle of

  16. Space Radiation Intelligence System (SPRINTS), Phase I

    National Aeronautics and Space Administration — NextGen Federal Systems proposes an innovative SPace Radiation INTelligence System (SPRINTS) which provides an interactive and web-delivered capability that...

  17. Effect of gamma radiation on graphite - PTFE dry lubrication system

    Singh, Sachin; Tyagi, Mukti; Seshadri, Geetha; Tyagi, Ajay Kumar; Varshney, Lalit

    2017-12-01

    An effect of gamma radiation on lubrication behavior of graphite -PTFE dry lubrication system has been studied using (TR-TW-30L) tribometer with thrust washer attachment in plane contact. Different compositions of graphite and PTFE were prepared and irradiated by gamma rays. Gamma radiation exposure significantly improves the tribological properties indicated by decrease in coefficient of friction and wear properties of graphite -PTFE dry lubrication system. SEM and XRD analysis confirm the physico-chemical modification of graphite-PTFE on gamma radiation exposure leading to a novel dry lubrication system with good slip and anti friction properties.

  18. Radiation management computer system for Monju

    Aoyama, Kei; Yasutomo, Katsumi; Sudou, Takayuki; Yamashita, Masahiro; Hayata, Kenichi; Ueda, Hajime; Hosokawa, Hideo

    2002-01-01

    Radiation management of nuclear power research institutes, nuclear power stations and other such facilities are strictly managed under Japanese laws and management policies. Recently, the momentous issues of more accurate radiation dose management and increased work efficiency has been discussed. Up to now, Fuji Electric Company has supplied a large number of Radiation Management Systems to nuclear power stations and related nuclear facilities. We introduce the new radiation management computer system with adopted WWW technique for Japan Nuclear Cycle Development Institute, MONJU Fast Breeder Reactor (MONJU). (author)

  19. Synchrotron radiation total reflection for rainwater analysis

    Simabuco, Silvana M.; Matsumoto, Edson

    1999-01-01

    Total reflection X-ray fluorescence analysis excited with synchrotron radiation (SR-TXRF) has been used for rainwater trace element analysis. The samples were collected in four different sites at Campinas City, SP. Standard solutions with gallium as internal standard were prepared for the calibration system. Rainwater samples of 10 μl were putted onto Perspex reflector disk, dried on vacuum and analyzed for 100 s measuring time. The detection limits obtained for K-shell varied from 29 ng.ml -1 for sulfur to 1.3 ng.ml -1 for zinc and copper, while for L-shell the values were 4.5 ng.ml -1 for mercury and 7.0 ng.ml -1 for lead. (author)

  20. Graphic system for the analysis of representation of a complex three-dimensional configuration for radiation shield calculation

    Berezhkov, A.B.; Gordeeva, E.K.; Mazanov, V.L.; Solov'ev, V.Yu.; Ryabov, A.V.; Khokhlov, V.F.; Shejno, I.N.

    1987-01-01

    Programs for obtaining phantom images when calculating the radiation shield structure for nuclear-engineering plants, using computer graphics, are developed. Programs are designed to accompany calculational investigations using the SUPER2/RRI3-PICSCH program and ZAMOK-TOMOGRAF program comutering complexes. Design geometry techniques, allowing to present three-dimensional object in the form of two-dimensional perspective projection to the screen plane, are realized in the programs

  1. Radiation chemistry of polymeric system

    Machi, Sueo; Ishigaki, Isao

    1978-01-01

    Among wide application of radiation in the field of polymer chemistry, practices of polymerization, graft polymerization, bridging, etc. are introduced hereinafter. As for the radiation sources of radiation polymerization, in addition to the 60 Co-γ ray with long permeation distance which has been usually applied, electron beam accelerators with high energy, large current and high reliability have come to be produced, and the liquid phase polymerization by electron beam has attracted attention industrially. Concerning polymerizing reactions, explanations were given to electron beam polymerization under high dose rate, the polymerization in supercooling state or under high pressure, and emulsifying polymerization. As for radiation bridging, radiation is applied for the bridging of hydrogel, acceleration of bridging and improvement of radiation resistance. It is also utilized for reforming membranes by graft polymerization, and synthesis of polymers for medical use. Application of fixed enzymes in the medical field has been investigated by fixing various enzymes by low temperature γ-ray polymerization with glassy monomers such as HEMA. (Kobatake, H.)

  2. Radiation damage analysis by positron annihilation spectroscopy

    Siegel, R.W.

    1982-01-01

    Positron annihilation spectroscopy (PAS) has in recent years become a valuable new tool for investigating defects in metals. The ability of the positron to localize in a trapped state at various defect sites, in which the positron annihilates with unique characteristics, has enabled the positron to be used as a localized probe of these defect sites. Several reviews of the application of PAS to the study of defects in metals have been published, as have more general treatises on the applications of positron annihilation to the study of solids. PAS has made, and has considerably greater potential for, a significant contribution to radiation damage analysis in two areas of importance: (1) the determination of atomic-defect properties, a knowledge of which is necessary for the modeling required to couple the results of model experiments using electron and ion irradiation with the expected irradiation conditions of reactor systems, and (2) the monitoring and characterization of irradiation-induced microstructure development. A unique aspect of PAS for radiation damage analysis is the defect specificity of the annihilation characteristics of a trapped positron. In addition to its value as an independent analytical tool, PAS can be a useful complement to more traditional techniques for defect studies

  3. Integrated Radiation Analysis and Design Tools

    National Aeronautics and Space Administration — The Integrated Radiation Analysis and Design Tools (IRADT) Project develops and maintains an integrated tool set that collects the current best practices, databases,...

  4. Snail-induced epithelial-to-mesenchymal transition of MCF-7 breast cancer cells: systems analysis of molecular changes and their effect on radiation and drug sensitivity

    Mezencev, Roman; Matyunina, Lilya V.; Jabbari, Neda; McDonald, John F.

    2016-01-01

    Epithelial-to-mesenchymal transition (EMT) has been associated with the acquisition of metastatic potential and the resistance of cancer cells to therapeutic treatments. MCF-7 breast cancer cells engineered to constitutively express the zinc-finger transcriptional repressor gene Snail (MCF-7-Snail cells) have been previously shown to display morphological and molecular changes characteristic of EMT. We report here the results of a comprehensive systems level molecular analysis of changes in global patterns of gene expression and levels of glutathione and reactive oxygen species (ROS) in MCF-7-Snail cells and the consequence of these changes on the sensitivity of cells to radiation treatment and therapeutic drugs. Snail-induced changes in global patterns of gene expression were identified by microarray profiling using the Affymetrix platform (U133 Plus 2.0). The resulting data were processed and analyzed by a variety of system level analytical methods. Levels of ROS and glutathione (GSH) were determined by fluorescent and luminescence assays, and nuclear levels of NF-κB protein were determined by an ELISA based method. The sensitivity of cells to ionizing radiation and anticancer drugs was determined using a resazurin-based cell cytotoxicity assay. Constitutive ectopic expression of Snail in epithelial-like, luminal A-type MCF-7 cells induced significant changes in the expression of >7600 genes including gene and miRNA regulators of EMT. Mesenchymal-like MCF-7-Snail cells acquired molecular profiles characteristic of triple-negative, claudin-low breast cancer cells, and displayed increased sensitivity to radiation treatment, and increased, decreased or no change in sensitivity to a variety of anticancer drugs. Elevated ROS levels in MCF-7-Snail cells were unexpectedly not positively correlated with NF-κB activity. Ectopic expression of Snail in MCF-7 cells resulted in morphological and molecular changes previously associated with EMT. The results underscore the

  5. System analysis and design

    Son, Seung Hui

    2004-02-01

    This book deals with information technology and business process, information system architecture, methods of system development, plan on system development like problem analysis and feasibility analysis, cases for system development, comprehension of analysis of users demands, analysis of users demands using traditional analysis, users demands analysis using integrated information system architecture, system design using integrated information system architecture, system implementation, and system maintenance.

  6. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    Faria, Rita; McKenna, Claire; Wade, Ros; Yang, Huiqin; Woolacott, Nerys; Sculpher, Mark

    2013-01-01

    Objectives: To evaluate the cost-effectiveness of the EOS ® 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS ® to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS ® is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS ® is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS ® is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS ® . The health benefits from radiation dose reductions are very small. Unless EOS ® can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness

  7. The EOS 2D/3D X-ray imaging system: A cost-effectiveness analysis quantifying the health benefits from reduced radiation exposure

    Faria, Rita, E-mail: rita.nevesdefaria@york.ac.uk [Centre for Health Economics, University of York, York (United Kingdom); McKenna, Claire [Centre for Health Economics, University of York, York (United Kingdom); Wade, Ros; Yang, Huiqin; Woolacott, Nerys [Centre for Reviews and Dissemination, University of York, York (United Kingdom); Sculpher, Mark [Centre for Health Economics, University of York, York (United Kingdom)

    2013-08-15

    Objectives: To evaluate the cost-effectiveness of the EOS{sup ®} 2D/3D X-ray imaging system compared with standard X-ray for the diagnosis and monitoring of orthopaedic conditions. Materials and methods: A decision analytic model was developed to quantify the long-term costs and health outcomes, expressed as quality-adjusted life years (QALYs) from the UK health service perspective. Input parameters were obtained from medical literature, previously developed cancer models and expert advice. Threshold analysis was used to quantify the additional health benefits required, over and above those associated with radiation-induced cancers, for EOS{sup ®} to be considered cost-effective. Results: Standard X-ray is associated with a maximum health loss of 0.001 QALYs, approximately 0.4 of a day in full health, while the loss with EOS{sup ®} is a maximum of 0.00015 QALYs, or 0.05 of a day in full health. On a per patient basis, EOS{sup ®} is more expensive than standard X-ray by between £10.66 and £224.74 depending on the assumptions employed. The results suggest that EOS{sup ®} is not cost-effective for any indication. Health benefits over and above those obtained from lower radiation would need to double for EOS to be considered cost-effective. Conclusion: No evidence currently exists on whether there are health benefits associated with imaging improvements from the use of EOS{sup ®}. The health benefits from radiation dose reductions are very small. Unless EOS{sup ®} can generate additional health benefits as a consequence of the nature and quality of the image, comparative patient throughput with X-ray will be the major determinant of cost-effectiveness.

  8. Development of Software for Measurement and Analysis of Solar Radiation

    Mohamad Idris Taib; Abul Adli Anuar; Noor Ezati Shuib

    2015-01-01

    This software was under development using LabVIEW to be using with StellarNet spectrometers system with USB communication to computer. LabVIEW have capabilities in hardware interfacing, graphical user interfacing and mathematical calculation including array manipulation and processing. This software read data from StellarNet spectrometer in real-time and then processed for analysis. Several measurement of solar radiation and analysis have been done. Solar radiation involved mainly infra-red, visible light and ultra-violet. With solar radiation spectrum data, information of weather and suitability of plant can be gathered and analyzed. Furthermore, optimization of utilization and safety precaution of solar radiation can be planned. Using this software, more research and development in utilization and safety of solar radiation can be explored. (author)

  9. Radiation energy calibrating system and method

    Jacobson, A.F.

    1980-01-01

    A radiation energy calibrating system and method which uses a pair of calibrated detectors for measurements of radiation intensity from x-ray tubes for a non-invasive determination of the electrical characteristics; I.E., the tube potential and/or current

  10. Solar radiation for Mars power systems

    Appelbaum, Joseph; Landis, Geoffrey A.

    1991-01-01

    Detailed information about the solar radiation characteristics on Mars are necessary for effective design of future planned solar energy systems operating on the surface of Mars. A procedure and solar radiation related data from which the diurnally and daily variation of the global, direct (or beam), and diffuse insolation on Mars are calculated, are presented. The radiation data are based on measured optical depth of the Martian atmosphere derived from images taken of the Sun with a special diode on the Viking Lander cameras; and computation based on multiple wavelength and multiple scattering of the solar radiation.

  11. Radiation damage prediction system using damage function

    Tanaka, Yoshihisa; Mori, Seiji

    1979-01-01

    The irradiation damage analysis system using a damage function was investigated. This irradiation damage analysis system consists of the following three processes, the unfolding of a damage function, the calculation of the neutron flux spectrum of the object of damage analysis and the estimation of irradiation effect of the object of damage analysis. The damage function is calculated by applying the SAND-2 code. The ANISN and DOT3, 5 codes are used to calculate neutron flux. The neutron radiation and the allowable time of reactor operation can be estimated based on these calculations of the damage function and neutron flux. The flow diagram of the process of analyzing irradiation damage by a damage function and the flow diagram of SAND-2 code are presented, and the analytical code for estimating damage, which is determined with a damage function and a neutron spectrum, is explained. The application of the irradiation damage analysis system using a damage function was carried out to the core support structure of a fast breeder reactor for the damage estimation and the uncertainty evaluation. The fundamental analytical conditions and the analytical model for this work are presented, then the irradiation data for SUS304, the initial estimated values of a damage function, the error analysis for a damage function and the analytical results are explained concerning the computation of a damage function for 10% total elongation. Concerning the damage estimation of FBR core support structure, the standard and lower limiting values of damage, the permissible neutron flux and the allowable years of reactor operation are presented and were evaluated. (Nakai, Y.)

  12. Radiation as an aid to analysis

    NONE

    1965-03-15

    Radiochemical methods of analysis possess some special advantages, such as rapidity and great sensitivity, and can on occasion provide results which would not be attainable by other means. They are finding an increasing number and variety of applications not only in pure research, but in medicine and health, in many industries such as mining, textiles, metallurgy and the oil industry, and in some other fields such as archaeology and criminology. These matters were discussed at an IAEA symposium at Salzburg, 19 - 23 October 1964, in which 278 participants joined, from 28 countries and five international organizations. Most of the emphasis at the conference was on radioactivation analysis, which occupied six out of the nine sessions. Under this method, the material to be studied is exposed to neutrons or charged particles, or electromagnetic radiation such as X-rays. This causes nuclear transformations in the material, followed by radioactive decay. Each element forms nuclides which emit radiation of characteristic energy and half-life, by which the element can be identified and measured. Sessions were devoted to various applications, using as the source of radiation nuclear reactors, accelerators, and radioisotope sources; experimental techniques and the application of computers to activation analysis were also considered. Two sessions were devoted to the use of radioactive tracers in analysis, and one to the use of radioactive sources for elementary analysis by observing how radiation is absorbed and scattered, or how, when a sample is exposed to radiation, it emits secondary radiation

  13. Radiation as an aid to analysis

    1965-01-01

    Radiochemical methods of analysis possess some special advantages, such as rapidity and great sensitivity, and can on occasion provide results which would not be attainable by other means. They are finding an increasing number and variety of applications not only in pure research, but in medicine and health, in many industries such as mining, textiles, metallurgy and the oil industry, and in some other fields such as archaeology and criminology. These matters were discussed at an IAEA symposium at Salzburg, 19 - 23 October 1964, in which 278 participants joined, from 28 countries and five international organizations. Most of the emphasis at the conference was on radioactivation analysis, which occupied six out of the nine sessions. Under this method, the material to be studied is exposed to neutrons or charged particles, or electromagnetic radiation such as X-rays. This causes nuclear transformations in the material, followed by radioactive decay. Each element forms nuclides which emit radiation of characteristic energy and half-life, by which the element can be identified and measured. Sessions were devoted to various applications, using as the source of radiation nuclear reactors, accelerators, and radioisotope sources; experimental techniques and the application of computers to activation analysis were also considered. Two sessions were devoted to the use of radioactive tracers in analysis, and one to the use of radioactive sources for elementary analysis by observing how radiation is absorbed and scattered, or how, when a sample is exposed to radiation, it emits secondary radiation

  14. Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis

    Kim, Chun Soo; Bae, Dae Seok; Kim, Kyung Su; Park, Byung Yun; Koh, Young Kown

    2000-04-01

    As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria subshells and annular plates in the calandria, respectivdely. Finally, the feasibility study of the DUPIC fuel handling was performed, which has shown that all handling and inspection of the DUPIC fuel bundles be done remotely and behind a shielding wall. For the transportation of the DUPIC fuel, the preliminary study has shown that there shold be no technical problem th design a transportation cask for the fresh and spent DUPIC fuel bundles. For the storage of the fresh and spent DUPIC fuels, there is no the criticality safety problem unless the fuel bundle geometry is destroyed

  15. Compatibility analysis of DUPIC fuel (part 3) - radiation physics analysis

    Kim, Chun Soo; Bae, Dae Seok; Kim, Kyung Su; Park, Byung Yun; Koh, Young Kown

    2000-04-01

    As a part of the compatibility analysis of DUPIC fuel in CANDU reactors, the radiation physics calculations have been performed for the CANDU primary shielding system, thermal shield, radiation damage, transportation cask and storage. At first, the primary shield system was assessed for the DUPIC fuel core, which has shown that the dose rates and heat deposition rates through the primary shield of the DUPIC fuel core are not much different from those of natural uranium core because the power levels on the core periphery are similar for both cores. Secondly, the radiation effects on the critical components and the themal shields were assessed when the DUPIC fuel is loaded in CANDU reactors. Compared with the displacement per atom (DPA) of the critical component for natural uranium core, that for the DUPIC fuel core was increased by -30% for the innermost groove and the weld points and by -10% for the corner of the calandria subshells and annular plates in the calandria, respectivdely. Finally, the feasibility study of the DUPIC fuel handling was performed, which has shown that all handling and inspection of the DUPIC fuel bundles be done remotely and behind a shielding wall. For the transportation of the DUPIC fuel, the preliminary study has shown that there shold be no technical problem th design a transportation cask for the fresh and spent DUPIC fuel bundles. For the storage of the fresh and spent DUPIC fuels, there is no the criticality safety problem unless the fuel bundle geometry is destroyed.

  16. Radiation damping in focusing-dominated systems

    Huang, Zhirong; Chen, Pisin; Ruth, R.D.

    1995-01-01

    A quasi-classical method is developed to calculate the radiation damping of a relativistic particle in a straight, continuous focusing system. In one limiting case where the pitch angle of the particle θ p is much larger than the radiation opening angle 1/γ, the radiation power spectrum is similar to synchrotron radiation and the relative damping rate of the transverse action is proportional to the relative energy loss rate. In the other limiting case where θ p much-lt 1/γ, the radiation is dipole in nature and the relative damping rate of the transverse action is energy-independent and is much faster than the relative energy rate. Quantum excitation to the transverse action is absent in this focusing channel. These results can be extended to bent systems provided that the focusing field dominates over the bending field

  17. Solar radiation alert system : final report.

    2009-03-01

    The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...

  18. Radiation monitoring system based on EPICS

    Wang Weizhen; Li Jianmin; Wang Xiaobing; Hua Zhengdong; Xu Xunjiang

    2008-01-01

    Shanghai Synchrotron Radiation Facility (SSRF for short) is a third-generation light source building in China, including a 150 MeV injector, 3.5 GeV booster, 3.5 GeV storage ring and an amount of beam line stations. During operation, a mass of Synchrotron Radiation will be produced by electrons in the booster and the storage ring. Bremsstrahlung and neutrons will also be produced as a result of the interaction between the electrons, especially the beam loss, and the wall of the vacuum beam pipe. SSRF Radiation Monitoring System is established for monitoring the radiation dosage of working area and environment while SSRF operating. The system consists of detectors, intelligent data-collecting modules, monitoring computer, and managing computer. The software system is developed based on EPICS (Experimental Physics and Industrial Control System), implementing the collecting and monitoring the data output from intelligent modules, analyzing the data, and so on. (authors)

  19. Use of radiological evaluation system from the Instituto de Radioprotecao e Dosimetria in the analysis of recent radiation accidents

    Silva, Rodolfo Julio da

    2013-01-01

    The response to an emergency situation involving ionizing radiation requires the joint participation of professionals from various kind of knowledge, belonging to public and private organizations (in the local, state and federal levels). The theme radiation tends to be an additional challenging factor - considering that it's, usually, remembered for its macabre and ominous aspect, in spite of the benefits provided by it - which makes the implementation of actions to protect the public, emergency professionals, the environment and property, very difficult. To this, we can add the complicating factor that, in most cases, the technician (holder of basic or advanced on the subject) is far !Tom the place where this action unfolds. The accident/incident takes the form of a radioactive source (sometimes orphaned, one that gone astray or even stolen) that is found by a person unaware of the risks to which they are being exposed or, let not forget about it, the non-observance of safety standards in industries and workplaces, by their own operators. Thus, before integrating emergency response plans with conventional plans specific to the prompt response to radiological emergencies, it is necessary that some measures had been anticipated and that some actions had, already, been planned - with the intention of mitigate health, psychological and economical damage, in ali of kind. To do this, since in the course of the second decade of the second millennium, and since you own a portable personal computer (Note or Netbook), or even with a mobile device (cellular) with a bit more resources, both of them previously updated, a responder (or even a qualified technician that is next to that fact) may already guide, at least, about a safety distances !Tom the source. Since he had knowledge about some characteristics of the source (its individual data), he can plan ahead about the possible serious situation that unfolds itself and emergency responders will find, when it get to the site

  20. Automated TLD system for gamma radiation monitoring

    Nyberg, P.C.; Ott, J.D.; Edmonds, C.M.; Hopper, J.L.

    1979-01-01

    A gamma radiation monitoring system utilizing a commercially available TLD reader and unique microcomputer control has been built to assess the external radiation exposure to the resident population near a nuclear weapons testing facility. Maximum use of the microcomputer was made to increase the efficiency of data acquisition, transmission, and preparation, and to reduce operational costs. The system was tested for conformance with an applicable national standard for TLD's used in environmental measurements

  1. Integrated nuclear and radiation protection systems

    Oprea, I.; Oprea, M.; Stoica, V.; Cerga, V.; Pirvu, V.; Badea, E.

    1993-01-01

    A multifunctional radiation monitoring equipment, flexible and capable to meet virtually environmental radiation monitoring, activity measurement and computational requirements, for nuclear laboratories has been designed. It can be used as a radiation protection system, for radionuclide measurement in isotope laboratories, nuclear technology, health physics and nuclear medicine, nuclear power stations and nuclear industry. The equipment is able to measure, transmit and record gamma dose rate and isotope activities. Other parameters and functions are optionally available, such as: self-contained alarm level, system self-test, dose integrator, syringe volume calculation for a given dose corrected for decay, calibration factor, 99 Mo assays performing and background subtraction

  2. Measurement and Analysis of the Extreme Physical Shock Environment Experienced by Crane-Mounted Radiation Detection Systems.

    Boyd, M [Texas A & M Univ., College Station, TX (United States); Erchinger, J [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Marianno, C [Texas A & M Univ., College Station, TX (United States); Kallenbach, Gene A. [Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States); Grypp, M [US Dept. of the Navy

    2017-09-01

    Potentially, radiation detectors at ports of entry could be mounted on container gantry crane spreaders to monitor cargo containers entering and leaving the country. These detectors would have to withstand the extreme physical environment experienced by these spreaders during normal operations. Physical shock data from the gable ends of a spreader were recorded during the loading and unloading of a cargo ship with two Lansmont SAVER 9X30 units (with padding) and two PCB Piezotronics model 340A50 accelerometers (hard mounted). Physical shocks in the form of rapid acceleration were observed in all accelerometer units with values ranging from 0.20 g’s to 199.99 g’s. The majority of the shocks for all the Lansmont and PCB accelerometers were below 50 g’s. The Lansmont recorded mean shocks of 21.83 ± 13.62 g’s and 24.78 ± 11.49 g’s while the PCB accelerometers experienced mean shocks of 34.39 ± 25.51 g’s and 41.77 ± 22.68 g’s for the landside and waterside units, respectively. Encased detector units with external padding should be designed to withstand at least 200 g’s of acceleration without padding and typical shocks of 30 g’s with padding for mounting on a spreader.

  3. Gravitational radiation from electromagnetic systems

    Nikishov, A.I.; Ritus, V.I.

    1989-01-01

    It is shown that the spectrum of gravitational radiation of a charge e with mass m, undergoing finite motion in an electromagnetic field, smoothly varying in the neighborhood of the orbit over a region of the order of the radius of curvature, differs in the ultrarelativistic limit from the spectrum of the charge's electromagnetic radiation. The difference consists of the frequency-independent coefficient 4πGm 2 Λ 2 /e 2 , where Λ is of the order of the Lorentz factor of the charge and depends on the direction of the wave vector and on the behavior of the field in the above-indicated region. For a plane-wave external field the gravitational and electromagnetic spectra are strictly proportional to each other for arbitrary velocities of the charge. Localization of the external forces near the orbit violates this proportionality of the spectra and weakens the gravitational radiation by an amount of the order of the square of the Lorentz factor

  4. REMOTE AREA RADIATION MONITORING (RARM) ALTERNATIVES ANALYSIS

    NELSON RL

    2008-01-01

    The Remote Area Radiation Monitoring (RARM) system will be used to provide real-time radiation monitoring information to the operations personnel during tank retrieval and transfer operations. The primary focus of the system is to detect potential anomalous (waste leaks) or transient radiological conditions. This system will provide mobile, real-time radiological monitoring, data logging, and status at pre-selected strategic points along the waste transfer route during tank retrieval operations. The system will provide early detection and response capabilities for the Retrieval and Closure Operations organization and Radiological Control personnel

  5. Radiation damage analysis by positron annihilation spectroscopy

    Siegel, R.W.

    1979-01-01

    The application of positron annihilation spectroscopy (PAS) to the characterization and study of defects in metals produced by radiation damage is discussed. The physical basis for the positron annihilation techniques (lifetime, Doppler broadening, angular correlation) is introduced and the techniques briefly described. Some examples of the application of PAS to radiation damage analysis are presented with a view toward elucidating the particular advantages of PAS over more traditional defect characterization techniques

  6. Design of a wireless radiation telemetry system

    Chiang, H H [Chung Yuan Christian Coll. of Science and Engineering, Chung-Li, Taiwan; Chang, J K

    1976-12-01

    The wireless radiation telemetry system can be operated in all seasons. It is designed for the measurement of radiation intensities up to millicurie order at a distance of 1 Km or less. Its measuring error is +-0.01 percent deviation from the count rate of the typical direct-detecting instrument with the same radiation source. This error indicates that the accuracy is high enough for practical uses. This system is cheaper and more flexible, comparing with the corresponding cable facility. The line-of-sight transmission distance can be longer if the transmitting power is appropriately increased. All pulse type radiation detectors can be used as the input section of this system.

  7. Integrated occupational radiation exposure information system

    Hunt, H.W.

    1983-06-01

    The integrated (Occupational Radiation Exposure) data base information system has many advantages. Radiation exposure information is available to operating management in a more timely manner and in a more flexible mode. The ORE system has permitted the integration of scattered files and data to be stored in a more cost-effective method that permits easy and simultaneous access by a variety of users with different data needs. The external storage needs of the radiation exposure source documents are several orders of magnitude less through the use of the computer assisted retrieval techniques employed in the ORE system. Groundwork is being layed to automate the historical files, which are maintained to help describe the radiation protection programs and policies at any one point in time. The file unit will be microfilmed for topical indexing on the ORE data base

  8. Management information system on radiation protection

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela, E-mail: pabloag@cdtn.b, E-mail: lss@cdtn.b, E-mail: gmf@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-07-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  9. Management information system on radiation protection

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela

    2011-01-01

    Considering the flux complexity and the multi source information of all radiation protection activities on nuclear organizations, an effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. An effective management information system is an essential tool to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Such kind of distinct knowledge is useful to reach an effective management and support the human decision-making on nuclear organization. This paper presents a management information system based on Brazilian directives and regulations on radiation protection. Due to its generic characteristics, this radiation protection control system can be implemented on any nuclear organization by reediting the non restricted parameters which could differ considering all facilities and laboratories expected on-site with diverse technologies applications. This system can be considered as a powerful tool applied on the continuous management of radiation protection activities on nuclear organizations and research institutes as well as for long term planning, not only indicating how the safety activities are going, but why they are not going as well as planned where that is the case. (author)

  10. Dosimetric analysis of radiation sources to use in dermatological lesions

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures. Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  11. Radiation effects in IFMIF Li target diagnostic systems

    Molla, J.; Vila, R.; Shikama, T.; Horiike, H.; Simakov, S.; Ciotti, M.; Ibarra, A.

    2009-01-01

    Diagnostics for the lithium target will be crucial for the operation of IFMIF. Several parameters as the lithium temperature, target thickness or wave pattern must be monitored during operation. Radiation effects may produce malfunctioning in any of these diagnostics due to the exposure to high radiation fields. The main diagnostic systems proposed for the operation of IFMIF are reviewed in this paper from the point of view of radiation damage. The main tools for the assessment of the performance of these diagnostics are the neutronics calculations by using specialised codes and the information accumulated during the last decades on the radiation effects in functional materials, components and diagnostics for ITER. This analysis allows to conclude that the design of some of the diagnostic systems must be revised to assure the high availability required for the target system.

  12. A computer system for occupational radiation exposure information

    Hunt, H.W.

    1984-01-01

    A computerized occupational radiation exposure information system has been developed to maintain records for contractors at the U.S. Department of Energy's (DOE) Hanford Site. The system also allows indexing and retrieval of three million documents from microfilm, thus significantly reducing storage needs and costs. The users are linked by display terminals to the data base permitting them instant access to dosemetry and other radiation exposure information. Personnel dosemeter and bioassay results, radiation training, respirator fittings, skin contaminations and other radiation occurrence records are included in the data base. The system yields immediate analysis of radiological exposures for operating management and health physics personnel, thereby releasing personnel to use their time more effectively

  13. Performance analysis on utilization of sky radiation cooling energy for space cooling. Part 2; Hosha reikyaku riyo reibo system ni kansuru kenkyu. 2

    Marushima, S; Saito, T [Tohoku University, Sendai (Japan)

    1996-10-27

    Studies have been made about a heat accumulation tank type cooling system making use of radiation cooling that is a kind of natural energy. The daily operating cycle of the cooling system is described below. A heat pump air conditioner performs cooling during the daytime and the exhaust heat is stored in a latent heat accumulation tank; the heat is then used for the bath and tapwater in the evening; at night radiation cooling is utilized to remove the heat remnant in the tank for the solidification of the phase change material (PCM); the solidified PCM serves as the cold heat source for the heat pump air conditioner to perform cooling. The new system decelerates urban area warming because it emits the cooler-generated waste heat not into the atmosphere but into space taking advantage of radiation cooling. Again, the cooler-generated waste heat may be utilized for energy saving and power levelling. For the examination of nighttime radiation cooling characteristics, CaCl2-5H2O and Na2HPO4-12H2O were tested as the PCM. Water was used as the heating medium. In the case of a PCM high in latent heat capacity, some work has to be done for insuring sufficient heat exchange for it by, for instance, rendering the flow rate low. The coefficient of performance of the system discussed here is three times higher than that of the air-cooled type heat pump system. 8 refs., 5 figs., 4 tabs.

  14. Radiation effects on optical data transmission systems

    Leskovar, B.

    1989-01-01

    The state of the art of optical transmitters, low loss fiber waveguides and receivers in both steady state and pulsed radiation environments is reviewed and summarized. Emphasis is placed on the effects of irradiation on the performance of light emitting and laser diodes, optical fiber waveguides and photodiodes. The influence of radiation-induced attenuation of optical fibers due to total dose, dose rate, time after irradiation, temperature, radiation history, photobleaching, OH and impurity content, dopant type and concentration is described. The performance of candidate components of the transmission system intended for deployment in the Superconducting Super Collider Detector and primary beam tunnel nuclear environment is discussed

  15. Three-axis asymmetric radiation detector system

    Martini, Mario Pierangelo; Gedcke, Dale A.; Raudorf, Thomas W.; Sangsingkeow, Pat

    2000-01-01

    A three-axis radiation detection system whose inner and outer electrodes are shaped and positioned so that the shortest path between any point on the inner electrode and the outer electrode is a different length whereby the rise time of a pulse derived from a detected radiation event can uniquely define the azimuthal and radial position of that event, and the outer electrode is divided into a plurality of segments in the longitudinal axial direction for locating the axial location of a radiation detection event occurring in the diode.

  16. The RM-5000 system for radiation monitoring

    1997-01-01

    Eight models of radiation monitors can be assembled from independent modules for the agricultural firms, customs house, boundary transitions, for the control of transport and passenger flows and for prevention of the non-authorized moving of radioactive and fissionable materials. Two modules are a basis of the system - gamma radiation detector on the basis of plastic scintillator and neutrons detector on the basis of the proportional 3 He counters

  17. Radiation effects on biochemical systems

    Seddon, G.M.

    2000-04-01

    Xanthine oxidase catalyses the oxidative hydroxylation of hypoxanthine, xanthine and a wide range of carbonyl compounds. The enzyme exists as an oxidase and a dehydrogenase; both catalyze the oxidation of the same substrates. Steady state radiolysis and pulse radiolysis were used to generate oxidative and reductive free radicals. Their effects on the enzymatic activity of xanthine oxidase were determined. Initially inactivation studies were carried out to evaluate the extent to which radiolysis in aqueous solution affects the enzyme activity. Values of D 37 and G inactivation were calculated following irradiation in the presence of free radical scavengers and in the presence of catalase and superoxide dismutase. The kinetic constants Vmax and Km were also determined following radiolysis. The effect of ionising radiation on the iron content of xanthine oxidase was measured using atomic absorption spectrometry. Native gel electrophoresis and iso-electric focussing were performed in an attempt to demonstrate changes in the overall structure of the enzyme. The binding of xanthine oxidase to heparin was carried out by measuring, (1) the displacement of methylene blue (MB + ) from a heparin-MB + complex, (2) affinity chromatography and, (3) pulse radiolysis. The effect of irradiation on the binding process was investigated using techniques (1) and (2). Finally the radiation-induced conversion of xanthine oxidase to dehydrogenase was established. The results indicate that xanthine oxidase is inactivated greatest in the presence of air and irradiation causes Vmax to he reduced and Km to increase. The iron content of irradiated xanthine oxidase is unaffected. Electrophoresis shows the enzyme becomes fragmented and the isoelectric points of the fragments vary over a wide range of pH. Binding of xanthine oxidase to heparin as measured by displacement of MB + from a heparin-MB + complex suggests that irradiation increases the affinity of the enzyme for the polyanion, whereas

  18. Effect of Gamma radiation type on the quality of olive oil and analysis of new enzyme systems

    Ben Rhouma, Hiba

    2008-01-01

    The irradiation is applied more and more in the field of the agro-alimentary. Its effects make prone of sevral studies. During this work, We studied the effect of the gamma rays on the quality of the olive oil. For that the traditional methods (acidity, peroxide index, K232, K270 and the composition in fatty-acids) were realized beside new enzymatic methods. in this context, Its proved that the irradiated olive oil present physico-chemical properties better than that those untreated. The enzymatic systems of analyses prove to be inexpensive, precise, easy to use, more rapid and less dangerous. The results found by these methods are completely comparable with those of the traditional methods. (Author)

  19. Occupational irradiation by external radiation sources. Analysis of the control system data covering the period 1972 - 198a

    Karadzhov, A.; Velikov, V.

    1982-01-01

    Occupational irradiation data, made available by the system of individual dosimetric control, are analyzed. It is demonstrated that the annual dose distribution is in accordance with the logarithm of normal distribution. The obtained values of the average dose in industry, medicine, science and educatuin during the period 1972 through 1980 are respectively 3.7 mSv, 1.0 mSv and 0.45 mSv. In some lines the average annual dose considerably exceeds the average annual dose for the respective branch, e.g. for workers in gamma defectoscopy it amounts to 9.1 mSv, while for medical personnel of deep and curi therapy - 2.1 mSv. (author)

  20. Radiation analysis for a generic centralized interim storage facility

    Gillespie, S.G.; Lopez, P.; Eble, R.G.

    1997-01-01

    This paper documents the radiation analysis performed for the storage area of a generic Centralized Interim Storage Facility (CISF) for commercial spent nuclear fuel (SNF). The purpose of the analysis is to establish the CISF Protected Area and Restricted Area boundaries by modeling a representative SNF storage array, calculating the radiation dose at selected locations outside the storage area, and comparing the results with regulatory radiation dose limits. The particular challenge for this analysis is to adequately model a large (6000 cask) storage array with a reasonable amount of analysis time and effort. Previous analyses of SNF storage systems for Independent Spent Fuel Storage Installations at nuclear plant sites (for example in References 5.1 and 5.2) had only considered small arrays of storage casks. For such analyses, the dose contribution from each storage cask can be modeled individually. Since the large number of casks in the CISF storage array make such an approach unrealistic, a simplified model is required

  1. Radiation risks to the developing nervous system

    Kriegel, H.; Schmahl, W.; Stieve, F.E.; Gerber, G.B.

    1986-01-01

    A symposium dealing with 'Radiation Risks to the Developing Nervous System' held at Neuherberg, June 18-20, 1985 was organised by the Radiation Protection Programme of the Commission of the European Communities and the Gesellschaft fuer Strahlen- und Umweltforschung mbH. The proceedings of this symposium present up-to-date information on the development of the nervous system and the modifications caused by prenatal radiation there upon. A large part of the proceedings is devoted to the consequences of prenatal irradiation in experimental animals with respect to alterations in morphology, biochemistry and behaviour, to the influence of dose, dose rate and radiation quality and to the question whether damage of the brain can arise from a synergistic action of radiation together with other agents. Since animal models for damage to the human central nervous system have inherent short-comings due to the differences in structure, complexity and development it is discussed how experimental studies could be applied to the human situation. The most recent data on persons exposed in utero at Hiroshima and Nagasaki are reviewed. A round table discussion, published in full, analyses all this information with a view to radiation protection, and defines the areas where future studies are needed. Separate abstracts were prepared for papers in these proceedings. (orig./MG)

  2. Modernization of WWER-1000 radiation monitoring systems

    Smith, T.

    1995-01-01

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs

  3. Modernization of WWER-1000 radiation monitoring systems

    Smith, T [General Atomics, San Diego, CA (United States)

    1996-12-31

    A modernization scheme of the radiation monitoring system for WWER-1000 is proposed. It has a purpose to comply with international standards and to reduce operational and maintenance cost by deleting obsolete components and reducing the number of detector channels. Detailed layouts of I/C system architecture, digital radiation monitoring system (DRAMS) architecture and LRP block diagram are presented. If planned and implemented properly, this program can provide cost savings by reducing time required to access and display data and maintenance cost by deleting obsolete parts and decreasing the number of detector channels. 3 figs.

  4. Axial tomographic system for radiation diagnoses

    Crowther, T.J.

    1977-01-01

    The axial tomographic scanner consists of a source of hard radiation passing a fan shaped beam through a plane layer of the body under examination, a detector, and driving systems for the sequential displacement and rotation of the radiation source and the detector. The diagnosis is made by means of a data processing system offering extensive time overlap capability of the individual system functions. The data sets from transmission or absorption are processed in three independent subsystems, i.e., the scanning system, the processing system and the display system. The systems are made up of well-known modules, e.g., Nova 1200 or Eclipse 5200. Hence, as a result of the independent design of the data system, raw data will not be lost in case of faults in some subsystem. (DG) [de

  5. Centralized environmental radiation monitoring system in JAERI

    Katagiri, H.; Kobalyashi, H.

    1993-01-01

    JAERI has continued the environmental radiation background survey and monitoring to ensure the safety of the peoples around the institute since one year before the first criticality of JRR-1 (Japan Research Reactor No.1) in August 1957. Air absorbed doses from β and γ radiation, α and β radioactivity in air and the radioactivities in environmental samples were the monitoring items. For the monitoring of β and γ radiation and α and β radioactivity in air, monitoring station and the centralized automatic environmental radiation monitoring system applying a computer were established as a new challenging monitoring system for nuclear facility, which was the first one not only in Japan but also in the would in 1960 and since then the system has been renewed two times (in 1973 and 1988) by introducing the latest technology in the fields of radiation detection and computer control at each stage. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop arisen from thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles

  6. Centralized environmental radiation monitoring system in JAERI

    Katagiri, Hiroshi; Kobayashi, Hideo

    1993-03-01

    Japan Atomic Energy Research Institute (JAERI) has continued the radiation background survey and environmental radiation monitoring to ensure the safety of the residents around the Institute. For the monitoring of β and γ radiations and α and β radioactivities in air, the centralized automatic environmental radiation monitoring system (EMS) applying a computer with monitoring stations (MS) was established. The system has been renewed twice in 1973 and 1988. In 1962, a new concept emergency environmental γ-ray monitoring system (MP) was begun to construct and completed in 1965 independent of EMS. The first renewal of the EMS was carried out by focusing on the rapid and synthetic judgement and estimation of the environmental impacts caused by radiation and radioactive materials due to the operation of nuclear facilities by centralizing the data measured at MS, MP, a meteorological station, stack monitors and drainage monitoring stations under the control of computer. Present system renewed in 1988 was designed to prevent the interruption of monitoring due to computer troubles, communication troubles and power failures especially an instant voltage drop caused by thunder by reflecting the experiences through the operation and maintenance of the former system. Dual telemeters whose power is constantly supplied via batteries (capable of 10 min. monitoring after power failure) are equipped in the monitoring center to cope with telemeter troubles, which has operated successfully without any suspension being attributable to the power failures and telemeter troubles. (J.P.N.)

  7. Quality control of gamma radiation measuring systems

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  8. Environmental radiation monitoring system with GPS (global positioning system)

    Komoto, Itsuro

    2000-01-01

    This system combines a radiation monitoring car with GPS and a data processor (personal computer). It distributes the position information acquired through GPS to the data such as measured environmental radiation dose rate and energy spectrum. It also displays and edits the data for each measuring position on a map. Transmitting the data to the power station through mobile phone enables plan managers to easily monitor the environmental radiation dose rate nearby and proper emergency monitoring. (author)

  9. A control system of radiation protection at HESYRL

    Li Yuxiong; Li Juexin; Ning Xinquan

    1990-01-01

    A control system for radiation protection at Hefei National Synchrotron Radiation Laboratory (HESYRL) consists of three parts. They are a personal radiation safety interlock system, an automatic environmental radiation monitoring system and a data logging and management system for area radiation monitoring. Two-year operating experiments have shown that this system is reasonably designed, reliable, high-sensitive and automatic. The design principle, construction and operating status of each part of the system are introduced

  10. Optical fiber-applied radiation detection system

    Nishiura, Ryuichi; Uranaka, Yasuo; Izumi, Nobuyuki

    2001-01-01

    A technique to measure radiation by using plastic scintillation fibers doped radiation fluorescent (scintillator) to plastic optical fiber for a radiation sensor, was developed. The technique contains some superiority such as high flexibility due to using fibers, relatively easy large area due to detecting portion of whole of fibers, and no electromagnetic noise effect due to optical radiation detection and signal transmission. Measurable to wide range of and continuous radiation distribution along optical fiber cable at a testing portion using scintillation fiber and flight time method, the optical fiber-applied radiation sensing system can effectively monitor space radiation dose or apparatus operation condition monitoring. And, a portable type scintillation optical fiber body surface pollution monitor can measure pollution concentration of radioactive materials attached onto body surface by arranging scintillation fiber processed to a plate with small size and flexibility around a man to be tested. Here were described on outline and fundamental properties of various application products using these plastic scintillation fiber. (G.K.)

  11. Technology development for radiation shielding analysis

    Ha, Jung Woo; Lee, Jae Kee; Kim, Jong Kyung

    1986-12-01

    Radiation shielding analysis in nuclear engineering fields is an important technology which is needed for the calculation of reactor shielding as well as radiation related safety problems in nuclear facilities. Moreover, the design technology required in high level radioactive waste management and disposal facilities is faced on serious problems with rapidly glowing nuclear industry development, and more advanced technology has to be developed for tomorrow. The main purpose of this study is therefore to build up the self supporting ability of technology development for the radiation shielding analysis in order to achieve successive development of nuclear industry. It is concluded that basic shielding calculations are possible to handle and analyze by using our current technology, but more advanced technology is still needed and has to be learned for the degree of accuracy in two-dimensional shielding calculation. (Author)

  12. Radiation monitor system for nuclear power plants

    Wu Bingzhe; Guo Shusheng

    1990-12-01

    The system has 8 kinds of radiation monitors and 2 stage microcomputers designed for processing the data from each monitor, storaging the information, printing out and displaying on the colour CRT. The function of the system includes high-value alarm, warm alarm and failure alarm, so called t hree-level alarms . Two functions of the alarms are the threshold alarm and the tendency alarm, so that this system is an intelligency system. This system has high reliability and very wide range when LOCA accident takes place. It is aseismic and immune to industrial interference. The system can meet IEC-761-1 standard and is of nuclear safety 3rd class. Also the following monitors were designed: 133 Xe monitor, 131 I monitor, low-level liquid monitor and high radiation γ area monitor. The system can meet the requirements of nuclear power plants

  13. Electron Radiation Belts of the Solar System

    Mauk, Barry; Fox, Nicola

    To address the question of what factors dictate similarities and differences between radiation belts, we present comparisons between the electron radiation belt spectra of all five strongly magnetized planets within the solar system: Earth, Jupiter, Saturn, Uranus, and Neptune. We choose the highest intensity observed electron spectrum within each system (highest specifically near 1 MeV) and compare them against expectations based on the so-called Kennel-Petschek limit (KP; 1966) for each system. For evaluating the KP limit, we begin with the new relativis-tically correct formulation of Summers et al. (2009) but then add several refinements of our own. Specifically, we: 1) utilized a much more flexible analytic spectral shape that allows us to accurately fit observed radiation belt spectra; 2) adopt the point of view that the anisotropy parameter is not a free parameter but must take on a minimal value, as originally proposed by Kennel and Petschek (1966); and 3) examine the differential characteristics of the KP limit along the lines of what Schulz and Davidson (1988) performed for the non-relativistic formula-tion. We find that three factors limit the highest electron radiation belt intensities within solar system planetary magnetospheres: a) whistler mode interactions that limit spectral intensities to a differential Kennel-Petschek limit (3 planets); b) the absence of robust acceleration pro-cesses associated with injection dynamics (1 planet); and c) material interactions between the radiation particles and clouds of gas and dust (1 planet).

  14. Analysis of T101 outage radiation dose

    Li, Zhonghua

    2008-01-01

    Full text: Collective radiation dose during outage is about 80% of annual collective radiation dose at nuclear power plants (NPPs). T 101 Outage is the first four-year outage of Unit 1 at Tianwan Nuclear Power Station (TNPS) and thorough overhaul was undergone for the 105-day's duration. Therefore, T 101 Outage has significant reference meaning to reducing collective radiation dose at TNPS. This paper collects the radiation dose statistics during T 101 Outage and analyses the radiation dose distribution according to tasks, work kinds and varying trend of the collective radiation dose etc., comparing with other similar PWRs in the world. Based on the analysis this paper attempts to find out the major factors in collective radiation dose during T 101 Outage. The major positive factor is low radiation level at workplace, which profits from low content of Co in reactor construction materials, optimised high-temperature p H value of the primary circuit coolant within the tight range and reactor operation without trips within the first fuel cycle. One of the most negative factors is long outage duration and many person-hours spent in the radiological controlled zone, caused by too many tasks and inefficient work. So besides keeping good performance of reducing radioactive sources, it should be focused on how to improve implementation of work management including work selection, planning and scheduling, work preparation, work implementation, work assessment and feedback, which can lead to reduced numbers of workers needed to perform a task, of person-hours spent in the radiological controlled zone. Moreover, this leads to reduce occupational exposures in an ALARA fashion. (author)

  15. Molecular analysis of radiation-induced mutations in vitro

    Kronenberg, A.

    1996-01-01

    This review will focus on the nature of specific locus mutations detected in mammalian cells exposed in vitro to different types of ionizing radiations. Ionizing radiation has been shown to produce a wide variety of heritable alterations in DNA. These range from single base pair substitutions to stable loss or translocation of large portions of whole chromosomes. Data will be reviewed for certain test systems that reveal different mutation spectra. Techniques for the analysis of molecular alterations include applications of the polymerase chain reaction, some of which may be coupled with DNA sequence analysis, and a variety of hybridization-based techniques. The complexity of large scale rearrangements is approached with cytogenetic techniques including high resolution banding and various applications of the fluorescence in situ hybridization (FISH) technique. Radiation-induced mutant frequencies and mutation spectra are a function of the linkage constraints on the recovery of viable mutants for a given locus and test system. 44 refs

  16. Immune system investigations for radiation workers

    Obreja, Doina; Tulbure, Rodica; Marinescu, Irina

    2001-01-01

    During the last decade a great deal of attention has been paid to the research in the field of the immune system. Some important steps forward have been achieved in understanding the mechanisms of action and control of the immunologic responses. At the same time the concern for the possible health effects of exposure to ionizing radiation has considerably increased. On the purpose of the evaluation of the modifications induced by the ionizing radiation for radiation workers, we have applied the method of lymphocytic subpopulations, a method that evinces the proportions for the various subtypes of lymphocytes having different roles within the immune system. A number of 62 persons, employees of the Institute of Physics and Nuclear Engineering at Bucharest - Magurele were involved in this study. All radiation workers from 2 departments characterized by a high exposure to ionizing radiation were included, as follows: Group no. 1, consisting of 20 persons working at RWTS (Radioactive Waste Treating Station), thus presenting both external and internal irradiation; Group no. 2, consisting of 18 persons working at RPC (Radioactive Isotopes Preparing Center), a place where besides the radioactive contamination, the chemical risk was also present. The control group (consisting of 24 persons) was formed of employees from the same institute, with the difference that they were not radiation workers. For the statistical processing of the results the programs EPI INFO 6 and CIA were used. Significantly, when analyzing globally the lymphocytic modifications for TT and/or B lymphocytes (either increments or decrements when compared to the normal values), a noticeable statistical difference among the groups in terms of the frequency of the immune system modifications (Hi square test p=0.001) occurs. The results are in accordance to those in special literature mentioning age as a factor having a role in the appearance of the immune modifications. The obtained results indicate a

  17. A new system for radiation monitoring

    Toivonen, H.

    1993-01-01

    The Finnish authorities are acquiring a new radiation monitoring system enabling realtime transmission of information on the radiation situation. The system will also gather meteorological data and make predictions on the movements of a radioactive cloud. The data are stored in a database, from which they can be retrieved onto a user's workstation. Each user can get an overall picture of the current situation by viewing a set of files which are produced automatically by the system. Upon receiving notice of a hazard, the system contacts the paging devices of the officers on call. When the notice comes from a single station, the system automatically reads the measurement data of all stations within 50 kilometers. The system, development of which began in 1992, will be put to use early next year. (orig.)

  18. Standardization of penetrating radiation testing system

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  19. EDGAR, a new plant radiation monitoring system

    Vuong, Q.M.; Da Costa Vieira, D.

    2004-01-01

    The EDGAR system is a new radiation monitoring system for nuclear power plant, reprocessing plant and nuclear research reactor for radioactive contamination, gamma and neutron field monitoring. Developed by French Atomic Energy Agency, this system provides not only complete functions of standard RMS, also allows spectroscopy level detection of alpha and beta particles based on a patented collimator unit. A complete computerized approach has been taken allowing full installation control in a single PC based display and communication unit. (author)

  20. Automatic radiation measuring system connected with GPS

    Tanigaki, Minoru

    2014-01-01

    The most serious nuclear disaster in Japan has broken out at Fukushima Daiichi Nuclear Power Plant due to Great East Japan Earthquake. Prompt and exact mapping of the contamination is of great importance for radiation protection and for the environment restoration. We have developed radiation survey systems KURAMA and KURAMA-2 for rapid and exact measurement of radiation dose distribution. The system is composed of a mobile radiation monitor and the computer in office which is for the storage and visualization of the data. They are connected with internet and are operated for continuous radiation measurement while the monitor is moving. The mobile part consists of a survey meter, an interface to transform the output of the survey meter for the computer, a global positioning system, a computer to process the data for connecting to the network, and a mobile router. Thus they are effective for rapid mapping of the surface contamination. The operation and the performance of the equipment at the site are presented. (J.P.N.)

  1. Radiation and electrical safety systems for PEP

    Smith, H.; Constant, T.; Crook, K.; Fitch, J.; Taylor, T.

    1981-02-01

    At SLAC, the Personnel Protection System (PPS) protects people from radiation hazards. For PEP, the system has been expanded to include protection against electrical and RF hazards. This paper describes the overall system design, giving particular attention to the novel features not found in similar systems in other areas of SLAC. These include the Restricted Access Mode to allow limited occupancy in the ring while high voltage or RF may be present, the automatic badge reader system for improving the efficiency of entry logging and control, and the solid state lighting control system for switching large lighting loads with minimum electro-magetic interference

  2. Study of national registration systems for health records of radiation workers. National radiation dose registration system

    Nakagawa, Haruo; Kanda, Keiji

    1999-01-01

    A national radiation dose registration system is proposed in this paper. In Japan, only one radiation dose registration system is partly effective. It is applied for workers in nuclear power plants which are under control of regulatory laws for nuclear reactors. The total system was proposed previously by the Committee for Compensation Claims of Nuclear Accidents. The reason for the delay in establishing a registration system for all radiation workers is supposedly a lack of effort to adjust differences among items in radiation protection laws and the promotion of public acceptance to atomic power. Items about dose recordings, record keeping and dose-record reporting in all of the radiation regulatory laws are compared to each other, and items were extracted for revision. (author)

  3. New type of radiation instrumentation system

    Matsuo, Keichi; Takaoka, Akira; Uranaka, Yasuo

    2000-01-01

    The Mitsubishi Electric Co., Ltd. developed a radiation instrumentation system introduced some recent techniques such as computation technique, network technique and so on into conventional radiation detection aiming at general market except power generation company. In a conventional system, a detector and an operation processing board was placed at a field and center, respectively, and a feeble pulse signal from the detector was transferred to the operation processing board. Then, on establishment of cables, detectors and operation processing board, it is essential to carry out engineering planning and field engineering conceiving on noise countermeasure. Noise resistance of the new type of radiation instrumentation system, not by adding operation processing function and network interface function into a detector unit in a field to transfer feeble signal, but by transferring testing result as a digital signal. And, noise removing function capable of selectively passing only signal pulse waveform from the detector to judge its signal waveform was also added to a detector unit in the field, to carry out a thoroughly removing noise. In addition, by connecting between each apparatus placed at the field with a network a system capable of reducing some cable engineering could be executed. Here were introduced on abstract of this new type of radiation instrumentation system and on noise removing function of its characteristics. (G.K.)

  4. Proteomics analysis of ram sperm by heavy ion radiation

    He Yuxuan; Li Hongyan; Zhang Hong

    2013-01-01

    The objective of this study was to investigate the proteome changes induced by heavy ion radiation using irradiated ram sperm by a two-dimensional electrophoresis (2-DE) analysis. The 2D gels were stained with Coomassie Brilliant Blue. Differentially expressed proteins were detected by PDQuest 8.0 software and subjected to ion trap mass spectrometer equipped with a surveyor HPLC system, and differential protein spots were identified. Results showed there are five differential protein spots in irradiated sperm gels, four up-regulated protein spots and one spot missed. The differentially expressed protein spots were identified to be two up-regulated proteins including enolase, and enolase 1. It was concluded there was proteome changes induced by heavy ion radiation in ram sperm, which may be useful to clarify the physiology state of ram sperm in heavy ion radiation and provide a theoretical basis for radiation ram breeding. (authors)

  5. High intensity radiation imaging system

    Barrett, H.H.

    1976-01-01

    A nuclear imaging system is described for mapping a spatially distributed source of high energy nuclear particles from a living organ which has selectively absorbed a radioactive compound in which the nuclear energy is spatially coded by a zone plate positioned between the source and a spatial detector, and a half tone screen is positioned between the source and the zone plate to increase the definition of the image

  6. Radiation from systems with relativistic electrons

    Ternov, I.M.; Khalilov, V.R.; Bagrov, V.G.; Nikitin, M.M.

    1980-01-01

    Different methods of generation of electromagnetic radiation in the course of electron motion in external electromagnetic fields are considered. Singularities of ''free electron lasers'' (FEL), synchrotronous, ondulator and Compton radiation sources are discussed. The effect of induced radiation of electrons moving in a magnetic field is studied on the basis of the quantum theory methods. The results obtained are compared with the results of the classical theory. The theoretical and experimental results of the main singularities of the ondulator radiation (OR) are presented. It is shown that when the recoil effects are negligible and nonequidistancy of the energy spectrum of an electron in a magnetic field is of an error character, the results for the dose rate calculated by the quantum and classical theory methods completely coincide in the range of great filling numbers. Both in the quantum and classical theories the effects of the induced radiation of electrons moving in external electromagnetic fields (nonstationary in a general case) of a rather general type depend on two main mechanisms, which are nonequidistancy of the energy spectrum and the recoil effect (the quantum theory); appearance of phase and longitudinal electron bunching under the effect of an alternating radiation field (the classical theory). On the basis of the investigations the conclusion is made that OR can be successfully used for measuring the charged particle beam parameters (dispersion of angular spread and the absolute energy), as well as for measuring the amplitude of the magnetic field intensity in a space-periodic system

  7. Radiation response of the central nervous system

    Schultheiss, T.E.; Kun, L.E.; Ang, K.K.; Stephens, L.C.

    1995-01-01

    This report reviews the anatomical, pathophysiological, and clinical aspects of radiation injury to the central nervous system (CNS). Despite the lack of pathognomonic characteristics for CNS radiation lesions, demyelination and malacia are consistently the dominant morphological features of radiation myelopathy. In addition, cerebral atrophy is commonly observed in patients with neurological deficits related to chemotherapy and radiation, and neurocognitive deficits are associated with diffuse white matter changes. Clinical and experimental dose-response information have been evaluated and summarized into specific recommendations for the spinal cord and brain. The common spinal cord dose limit of 45 Gy in 22 to 25 fractions is conservative and can be relaxed if respecting this limit materially reduces the probability of tumor control. It is suggested that the 5% incidence of radiation myelopathy probably lies between 57 and 61 Gy to the spinal cord in the absence of dose modifying chemotherapy. A clinically detectable length effect for the spinal cord has not been observed. The effects of chemotherapy and altered fractionation are also discussed. Brain necrosis in adults is rarely noted below 60 Gy in conventional fractionation, with imaging and clinical changes being observed generally only above 50 Gy. However, neurocognitive effects are observed at lower doses, especially in children. A more pronounced volume effect is believed to exist in the brain than in the spinal cord. Tumor progression may be hard to distinguish from radiation and chemotherapy effects. Diffuse white matter injury can be attributed to radiation and associated with neurological deficits, but leukoencephalopathy is rarely observed in the absence of chemotherapy. Subjective, objective, management, and analytic (SOMA) parameters related to radiation spinal cord and brain injury have been developed and presented on ordinal scales

  8. Radiation response of the central nervous system

    Schultheiss, T.E.; Kun, L.E.; Stephens, L.C.

    1995-01-01

    This report reviews the anatomical, pathophysiological, and clinical aspects of radiation injury to the central nervous system (CNS). Despite the lack of pathoGyomonic characteristics for CNS radiation lesions, demyelination and malacia are consistently the dominant morphological features of radiation myelopathy. In addition, cerebral atrophy is commonly observed in patients with neurological deficits related to chemotherapy and radiation, and neurocognitive deficits are associated with diffuse white matter changes. Clinical and experimental dose-response information have been evaluated and summarized into specific recommendations for the spinal cord and brain. The common spinal cord dose limit of 45 Gn in 22 to 25 fractions is conservative and can be relaxed if respecting this limit materially reduces the probability of tumor control. It is suggested that the 5% incidence of radiation myelopathy probably lies between 57 and 61 Gy to the spinal cord in the absence of dose modifying chemotherapy. A clinically detectable length effect for the spinal cord has not been observed. The effects of chemotherapy and altered fractionation are also discussed. Brain necrosis in adults is rarely noted below 60 Gy in conventional fractionation, with imaging and clinical changes being observed generally only above 50 Gy. However, neurocognitive effects are observed at lower doses, especially in children. A more pronounced volume effect is believed to exist in the brain than in the spinal cord. Tumor progression may be hard to distinguish from radiation and chemotherapy effects. Diffuse white matter injury can be attributed to radiation and associated with neurological deficits, but leukoencephalopathy is rarely observed in the absence of chemotherapy. Subjective, objective, management, and analytic (SOMA) parameters related to radiation spinal cord and brain injury have been developed and presented on ordinal scales. 140 refs., 3 figs., 6 tabs

  9. Automated System of Area Radiation Measurement (ASARM)

    Hernandez G, J.

    2013-10-01

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  10. Prompt radiation activation analysis, (1) Theoretical study

    EL Barouni, A. M.; Araddad, S. Y.; Mosbah, D. S.; Elfakhri, S. M.; Rateb, J. M.; Benghzail, M. A.

    2004-01-01

    The measurement of the prompt γ following neutron capture in the reaction has been extensively developed. In this method the gamma-ray intensity is depended only upon the radiative capture cross-section and not upon the half-life of the product nucleus. The prompt gamma-ray activation analysis method stems from the radiative capture process which results in the decay of the compound nucleus by the emission of characteristic gamma radiation, either as a single photon with kinetic energy equal to the excitation energy less the recoil energy or, more likely, by a cascade of two or more photons with the same energy. The equations and the computer program required to calculate the yield, the intensity and the K χ emission probability per disintegration, are given in this study.(author)

  11. Fiber structural analysis by synchrotron radiation

    Kojima, J I; Kikutani, T

    2003-01-01

    Topics of fiber structural analysis by synchrotron radiation are explained. There are only three synchrotron radiation facilities in the world, SPring-8 (Super Photon ring-8) in Japan, APS (Advanced Photon Source) in U.S.A. and ESRF (European Synchrotron Radiation Facility) in France. Online measurement of melt spinning process of PET and Nylon6 is explained in detail. Polypropylene and PBO (poly-p-phenylenebenzobisoxazole) was measured by WAXD (Wide Angle X-ray Diffraction)/SAXS (Small Angle X-ray Scattering) at the same time. Some examples of measure of drawing process of fiber are described. The structure formation process of spider's thread was measured. Micro beam of X-ray of synchrotron facility was improved and it attained to 65nm small angle resolving power by 10 mu m beamsize. (S.Y.)

  12. Distributed radiation data acquisition system for KAPP

    Narsaiah, A.; Anantakrishnan, T.S.; Bairi, B.R.

    1992-01-01

    Increased concern for the safety of personnel working in Nuclear Power Stations demands an efficient centralized Radiation Data Acquisition System (RADAS) to monitor different types of radiation at distributed locations of the plant. The system provides a comprehensive picture of radio-activity level distribution in the reactor building to facilitate prompt and correct decision making to take care of any emergency situation. The system is build around an industrial IBM-PC connected to remote intelligent data acquisition units using serial data communication links. To ensure high system availability and ease of maintenance the mechanical moving disk storage has been replaced by solid state memory storage (RAM Disk). Functional CRT displays have been substituted by the assembly of IBM-PC Mother Board with built-in firmware and standard TV Monitor. The computer handles a variety of processing functions which include the conversion to engineering units, checking of alarms, display/printing of plant radiation level status and system diagnostics. Intelligent terminals have been provided with graphic and text formatting capabilities. A hot standby computer connected to analog and digital inputs takes over the system functions on the failure of the host system. Modular software written in the higher level C-language runs under a standard real-time operating system Kernel. This provides for easy modification and expandability at site. Based on the experience of its commissioning at Kakrapar Power Station a new compact version is being designed for a specific application in another class of reactor. (author). 3 refs., 1 fig

  13. Ultraviolet Radiation in the Solar System

    Vázquez, M

    2006-01-01

    UV radiation is an important part in the electromagnetic spectrum since the energy of the photons is great enough to produce important chemical reactions in the atmospheres of planets and satellites of our Solar System, thereby affecting the transmission of this radiation to the ground and its physical properties. Scientists have used different techniques (balloons and rockets) to access to the information contained in this radiation, but the pioneering of this new frontier has not been free of dangers. The Sun is our main source of UV radiation and its description occupies the first two chapters of the book. The Earth is the only known location where life exists in a planetary system and therefore where the interaction of living organism with UV radiation can be tested through different epochs and on distinct species. The development of the human technology has affected the natural shield of ozone that protects complex lifeforms against damaging UV irradiation. The formation of the ozone hole and its consequ...

  14. Notions of radiation chemistry in biological systems

    Mastro, N.L. del.

    1989-10-01

    The present paper examines some aspects of the direct and indirect biological radiation effects: pair formation, free radicals, superoxide ion, hydrogen peroxide, hydroxyl radical, oxygen singlet together with the endogen radioprotector mechanisms of organisms and the ways in which an improved radioresistance of biochemical systems can be achieved. (author) [pt

  15. Development of aerial gamma radiation survey system, 1

    Tsutsumi, Masahiro; Saito, Komei; Sakamoto, Ryuichi; Nagaoka, Toshi; Moriuchi, Shigeru

    1986-05-01

    JAERI has started to develop an aerial gamma radiation survey system by a helicopter in 1980. The development of measuring instruments, the experiments in the field of natural and artificial radiation sources, and the imaginary emergency survey at a real site, were executed. This report describes mainly about the hardware and software of this system. The system consists of gamma-ray measuring instruments with NaI(Tl) scintillation detectors, microwave positioning instruments, and a data processing system for postflight data. A foreign-made geological survey system is improved on for radiation measurements. For covering the wide radiation range, detectors of various shapes and sizes are prepared, from a large volume detector, DET-1024 - four 4'' x 4'' x 16'' crystals assembly - to a 2'' diameter x 2'' NaI(Tl) crystal. Radiation and position data are recorded on a magnetic tape, and computer-processed afterwards. Moreover, scene below flight courses and internal communication are recorded on video tape with the information of clock and position superimposed. In consequence of field experiments carried out five times, basic radiation data for evaluating airborne acquired data are accumulated, and flight survey procedures are established. As more practical use, a system has been produced more compactly and functionally. Exposure rates (> 1 mR/h), energy distribution spectra, and energy window counts are obtained for radiation data. Using the Spectrum-Dose Conversion Method, the accurate exposure rates are directly calculated from pulse height spectra. Numerical tables of G(E) function converting pulse height spectra into exposures are shown in this report. As regards the analysis of survey data, process codes have been completed with either large-computer or mini-computer. (author)

  16. Radiation and environmental data analysis computer (REDAC) hardware, software band analysis procedures

    Hendricks, T.J.

    1985-01-01

    The REDAC was conceived originally as a tape verifier for the Radiation and Environmental Data Acquisition Recorder (REDAR). From that simple beginning in 1971, the REDAC has evolved into a family of systems used for complete analysis of data obtained by the REDAR and other acquisition systems. Portable or mobile REDACs are deployed to support checkout and analysis tasks in the field. Laboratory systems are additionally used for software development, physics investigations, data base management and graphics. System configurations range from man-portable systems to a large laboratory-based system which supports time-shared analysis and development tasks. Custom operating software allows the analyst to process data either interactively or by batch procedures. Analysis packages are provided for numerous necessary functions. All these analysis procedures can be performed even on the smallest man-portable REDAC. Examples of the multi-isotope stripping and radiation isopleth mapping are presented. Techniques utilized for these operations are also presented

  17. A radiation analysis of lunar surface habitats

    De Angelis, G.; Wilson, J.W.; Tripathi, R.K.; Clowdsley, M.S.; Nealy, J.E.

    2003-01-01

    An analysis is performed on the radiation environment found on the surface of the Moon, and applied to different possible lunar base mission scenarios. An optimization technique has been used to minimize the astronaut radiation exposure and at the same time control the effect of shielding, in terms of mass addition and material choice, as a mission cost driver. The optimization process performs minimization of mass along all phases of a mission scenario, considered in terms of time frame, equipment, location, crew characteristics and performance required, radiation exposure annual and career limit constraints (those proposed in NCRP 132), and implementation of the ALARA principle. In the lunar environment manned habitats are to host future crews involved in the construction and/or in the utilization of moon based infrastructure. Three different kinds of lunar missions are considered in the analysis, Moon Base Construction Phase, during which astronauts are on the surface just to build an outpost for future resident crews, Moon Base Outpost Phase, during which astronaut crews are resident but continuing exploration and installation activities, and Moon Base Routine Phase, with shifting resident crews. In each scenario various kinds of habitats, from very simple shelters to more complex bases, are considered in detail (e.g. shape, thickness, materials, etc) with considerations of various shielding strategies. The results for all scenarios clearly showed that the direct exposure to the space environment like in transfers and EVAs phases gives the most of the dose, with the proposed shielded habitats and shelters giving quite a good protection from radiation. Operational constraints on hardware and scenarios have all been considered by the optimization techniques. Within the limits of this preliminary analysis, the three Moon Base related mission scenarios are perfectly feasible from the astronaut radiation safety point of view with the currently adopted and proposed

  18. Radiation transmission pipe thickness measurement system

    Higashi, Yasuhiko

    2010-01-01

    Fuji Electric Systems can be measured from the outer insulation of the transmission Characteristics and radiation detection equipment had been developed that can measure pipe wall thinning in plant and running, the recruitment of another three-beam calculation method by pipe thickness measurement system was developed to measure the thickness of the pipe side. This equipment has been possible to measure the thickness of the circumferential profile of the pipe attachment by adopting automatic rotation. (author)

  19. Radiation control system of nuclear power plants

    Kapisovsky, V.; Kosa, M.; Melichar, Z.; Moravek, J.; Jancik, O.

    1977-01-01

    The SYRAK system is being developed for in-service radiation control of the V-1 nuclear power plant. Its basic components are an EC 1010 computer, a CAMAC system and communication means. The in-service release of radionuclides is measured by fuel can failure detection, by monitoring rare gases in the coolant, by gamma spectrometric coolant monitoring and by iodine isotopes monitoring in stack disposal. (O.K.)

  20. Progress report: 1996 Radiation Safety Systems Division

    Bhagwat, A.M.; Sharma, D.N.; Abani, M.C.; Mehta, S.K.

    1997-01-01

    The activities of Radiation Safety Systems Division include (i) development of specialised monitoring systems and radiation safety information network, (ii) radiation hazards control at the nuclear fuel cycle facilities, the radioisotope programmes at Bhabha Atomic Research Centre (BARC) and for the accelerators programme at BARC and Centre for Advanced Technology (CAT), Indore. The systems on which development and upgradation work was carried out during the year included aerial gamma spectrometer, automated environment monitor using railway network, radioisotope package monitor and air monitors for tritium and alpha active aerosols. Other R and D efforts at the division included assessment of risk for radiation exposures and evaluation of ICRP 60 recommendations in the Indian context, shielding evaluation and dosimetry for the new upcoming accelerator facilities and solid state nuclear track detector techniques for neutron measurements. The expertise of the divisional members was provided for 36 safety committees of BARC and Atomic Energy Regulatory Board (AERB). Twenty three publications were brought out during the year 1996. (author)

  1. Analysis of radiation risk to patients from intra-operative use of the mobile X-ray system (C-arm

    Yang-Sub Lee

    2015-01-01

    Full Text Available Background: The aim of this study was to investigate clinical applications of mobile C-arms and consequent radiation risk, to increase medical attention on radiation protection, and to provide basic data for safe radiation use in the operating room. Materials and Methods: In this study, a total of 374 surgical operations, conducted using a portable fluoroscopic X-ray system from January to March of 2013, were analyzed. Dose summaries produced by the General Electric C-arm and data elements in digital imaging and communications in the medicine header of Ziehm C-arm, fluoroscopy time were used to obtain dose-area product (DAP and effective dose. Corresponding mean and maximum values were calculated, and the resulting data on the frequency of application, fluoroscopy time, DAP, and effective dose were compared and analyzed in terms of surgical specialty and operation types. Results: Orthopedic surgery was the most frequent with 165 cases (44.1%. The highest DAP value and effective dose were found in liver transplant among surgical specialty fields, with mean values of 2.90 ± 3.76 mGy∙m 2 and 58 ± 75.2 mSv, respectively (P = 0.0001. The highest DAP value and effective dose were observed in intra-operative mesenteric portography among types of surgery, showing mean values of 2.90 ± 3.81 mGy∙m 2 and 58.03 ± 76.24 mSv, respectively (P = 0.0001. Conclusion: Because DAP varies significantly across surgical specialties and types of operation, aggressive efforts to understand the effects of radiation dose is critical for radiation protection from intra-operative use of mobile C-arms.

  2. Development of a distributed radiation detection system using optical fibers

    Jensen, F; Inouchi, Goro; Takada, Eiji; Takahashi, Hiroyuki; Iguchi, Tetsuo; Nakazawa, Masaharu [Tokyo Univ. (Japan). Faculty of Engineering; Kakuta, Tsunemi

    1996-07-01

    We have confirmed the importance of temperature and dose rate for the response of Ge-doped fibers to radiation. A phenomenological model have been found to account for temperature and dose rate effects. From this model it is possible to make dose predictions from attenuation measurements when the temperature and dose rate are known. Ge-doped fibers have been found to have a relatively low sensitivity to both neutron and gamma radiation. In addition, temperature and dose rate dependencies complicate the analysis. However we point out that these problems may all be solved if we use fibers, such as P-doped fibers, which contain color centers of long lifetime. This would remove both the temperature and dose rate dependencies that complicate the use of Ge-doped fibers, in addition the radiation sensitivity is increased. Finally OTDR has been investigated as a possible read-out method for distributed radiation measurements. For our system the minimum pulse length was 3ns, giving a spatial resolution in the meter range and a response length to radiation of about 10 m if accurate dose values where to be obtained. We found OTDR to be a suitable method for radiation induced attenuation measurements in optical fibers, especially for long fiber lengths and long time scales where questions of light source stability becomes important for other systems. (S.Y.)

  3. Advanced CMOS Radiation Effects Testing and Analysis

    Pellish, J. A.; Marshall, P. W.; Rodbell, K. P.; Gordon, M. S.; LaBel, K. A.; Schwank, J. R.; Dodds, N. A.; Castaneda, C. M.; Berg, M. D.; Kim, H. S.; hide

    2014-01-01

    Presentation at the annual NASA Electronic Parts and Packaging (NEPP) Program Electronic Technology Workshop (ETW). The material includes an update of progress in this NEPP task area over the past year, which includes testing, evaluation, and analysis of radiation effects data on the IBM 32 nm silicon-on-insulator (SOI) complementary metal oxide semiconductor (CMOS) process. The testing was conducted using test vehicles supplied by directly by IBM.

  4. Moon manned missions radiation safety analysis

    Tripathi, R. K.; Wilson, J. W.; de Anlelis, G.; Badavi, F. F.

    An analysis is performed on the radiation environment found on the surface of the Moon, and applied to different possible lunar base mission scenarios. An optimization technique has been used to obtain mission scenarios minimizing the astronaut radiation exposure and at the same time controlling the effect of shielding, in terms of mass addition and material choice, as a mission cost driver. The optimization process has been realized through minimization of mass along all phases of a mission scenario, in terms of time frame (dates, transfer time length and trajectory, radiation environment), equipment (vehicles, in terms of shape, volume, onboard material choice, size and structure), location (if in space, on the surface, inside or outside a certain habitats), crew characteristics (number, gender, age, tasks) and performance required (spacecraft and habitat volumes), radiation exposure annual and career limit constraint (from NCRP 132), and implementation of the ALARA principle (shelter from the occurrence of Solar Particle Events). On the lunar surface the most important contribution to radiation exposure is given by background Galactic Cosmic Rays (GCR) particles, mostly protons, alpha particles, and some heavy ions, and by locally induced particles, mostly neutrons, created by the interaction between GCR and surface material and emerging from below the surface due to backscattering processes. In this environment manned habitats are to host future crews involved in the construction and/or in the utilization of moon based infrastructure. Three different kinds of lunar missions are considered in the analysis, Moon Base Construction Phase, during which astronauts are on the surface just to build an outpost for future resident crews, Moon Base Outpost Phase, during which astronaut crews are resident but continuing exploration and installation activities, and Moon Base Routine Phase, with long-term shifting resident crews. In each scenario various kinds of habitats

  5. Troubles in vacuum system and radiation exposure

    Konno, Osamu

    1978-01-01

    It is about eleven years since the LINAC of 300 MeV in Tohoku University has first accelerated electrons. The maintenance and improvement of the accelerator used more than 10 years now give the related personnel an important problem of radiation exposure. 40 days were required for the maintenance and checking-up in 1977, and other 26 days were used for other construction works. The troubles in the vacuum system occurred 81 times in total. The vacuum system is divided into two subsystems, each being provided with a leak detector. Either of them enables to detect and locate the leak. Silver-alloy brazing of a duct with a cooling water tube has deteriorated in the strength because of repeated baking temperature and/or the copper tubes for cooling have been eroded due to the large local cell action by purified water. The similar phenomena have occurred in RF windows, outside of which is cooled with water. Carbonaceous matter has stuck to the element of the ion pump, but successfully been cleaned. Though the energy compression system was installed for the efficient use of electrons, the troubles due to overheating of the current monitor have increased because of its limited space, and the change of location was made. Considerable surface residual radiation dose was found at some parts of transport system, and a few personnel have been exposed to radiation over 1000 mrem/year as a result of the troubles in vacuum system. (Wakatsuki, Y.)

  6. Radiation systems for luggage and parcel checks

    Honomichl, V.

    1989-01-01

    The current radioscopic systems of luggage check in air traffic are based on the principle of intensifying the brightness of half-tone images on the fluorescent screen of an image intensifier, or use of very sensitive pick-up tubes with digital image processing. Computers are used for signal processing and the image is produced on a display unit. Sources of continuous or pulse X-ray radiation are used. The signals from the detector are amplified, converted and stored in a buffer and then displayed. The scanning systems use a narrow beam or, to improve rapidity and sensitivity of scanning, a sector beam of radiation. Equipment is described from Heinemann (FRG) featuring a band of 576 or 768 detectors and microprocessor controlled semiconductor tv cameras. Characteristics are also presented of equipment from Aeradio Ltd (U.K.) and Philips (FRG) companies. Attention is devoted to equipment from American Science and Engineering (U.S.) showing high quality imaging even at low radiation doses. Briefly described are portable check systems for inspection of small luggage and parcels. Characteristics are presented of systems for checking vehicles and containers in naval, air, rail and road transport. The principles and performance are described of the systems. (J.B.). 4 figs

  7. A real-time radiation mapping system

    Scoggins, W.A.; VanEtten, D.M.

    1988-01-01

    A prototype of a real-time radiation mapping system, Ranger, was developed to respond to an accident involving the release of plutonium for the Department of Energy's Accident Response Group. In 1987 Ranger demonstrated that it can provide an efficient method of monitoring large areas of land for radioactive contamination. With the experience gained from the operation of the prototype, the external computer and software are being upgraded in order to obtain a fully operational system. The new system uses the prototype's commercially available line-of-sight microwave system for determining position and the same radiation detection instruments. The data obtained from the radiation detection instrument(s) are linked back to the external computer along with the relative position of the measurement through the ranging system. The data are displayed on a gridded map as colored circles and permanently stored in real-time. The different colors represent different contamination levels. Contours can be drawn using the permanently stored data. 4 figs

  8. Design of online testing system of material radiation resistance

    Wan Junsheng; He Shengping; Gao Xinjun

    2014-01-01

    The capability of radiation resistance is important for some material used in some specifically engineering fields. It is the same principal applied in all existing test system that compares the performance parameter after radiation to evaluate material radiation resistance. A kind of new technique on test system of material radiation resistance is put forward in this paper. Experimentation shows that the online test system for material radiation resistance works well and has an extending application outlook. (authors)

  9. Passive-solar directional-radiating cooling system

    Hull, J.R.; Schertz, W.W.

    1985-06-27

    A radiative cooling system for use with an ice-making system having a radiating surface aimed at the sky for radiating energy at one or more wavelength bands for which the atmosphere is transparent and a cover thermally isolated from the radiating surface and transparent at least to the selected wavelength or wavelengths, the thermal isolation reducing the formation of condensation on the radiating surface and/or cover and permitting the radiation to continue when the radiating surface is below the dewpoint of the atmosphere, and a housing supporting the radiating surface, cover and heat transfer means to an ice storage reservoir.

  10. The analysis of radiation exposure of hospital radiation workers

    Jeong, Tae Sik; Shin, Byung Chul; Moon, Chang Woo; Cho, Yeong Duk; Lee, Yong Hwan; Yum, Ha Yong

    2000-01-01

    This investigation was performed in order to improve the health care of radiation workers, to predict a risk, to minimize the radiation exposure hazard to them and for them to realize radiation exposure danger when they work in radiation area in hospital. The documentations checked regularly for personal radiation exposure in four university hospitals in Pusan city in Korea between January 1, 1993 and December 31, 1997 were analyz ed. There were 458 persons in this documented but 111 persons who worked less then one year were excluded and only 347 persons were included in this study. The average of yearly radiation exposure of 347 persons was 1.52±1.35 mSv. Though it was less than 5OmSv, the limitaion of radiation in law but 125 (36%) people received higher radiation exposure than non-radiation workers. Radiation workers under 30 year old have received radiation exposure of mean 1.87±1.01 mSv/year, mean 1.22±0.69 mSv between 31 and 40 year old and mean 0.97±0.43 mSv/year over, 41year old (p<0.001). Men received mean 1.67±1.54 mSv/year were higher than women who received mean 1.13±0.61 mSv/year (p<0.01). Radiation exposure in the department of nuclear medicine department in spite of low energy sources is higher than other departments that use radiations in hospital (p<0.05). And the workers who received mean 3.69±1.81 mSv/year in parts of management of radiation sources and injection of sources to patient receive high radiation exposure in nuclear medicine department (0<0.01). In department of diagnostic radiology high radiation exposure is in barium enema rooms where workers received mean 3.74±1.74 mSv/year and other parts where they all use fluoroscopy such as angiography room of mean 1.17±0.35 mSv/year and upper gastrointestinal room of mean 1.74±1.34 mSv/year represented higher radiation exposure than average radiation exposure in diagnostic radiology (p<0.01). Doctors and radiation technologists received higher radiation exposure of each mean 1.75±1

  11. Real Time Wide Area Radiation Surveillance System

    Biafore, M.

    2012-04-01

    We present the REWARD project, financed within the FP7 programme, theme SEC-2011.1.5-1 (Development of detection capabilities of difficult to detect radioactive sources and nuclear materials - Capability Project). Within this project, we propose a novel mobile system for real time, wide area radiation surveillance. The system is based on the integration of new miniaturized solid-state radiation sensors: a CdZnTe detector for gamma radiation and a high efficiency neutron detector based on novel silicon technologies. The sensing unit will include a wireless communication interface to send the data remotely to a monitoring base station which also uses a GPS system to calculate the position of the tag. The system will also incorporate middleware and high level software to provide web-service interfaces for the exchange of information, and that will offer top level functionalities as management of users, mobile tags and environment data and alarms, database storage and management and a web-based graphical user interface. Effort will be spent to ensure that the software is modular and re-usable across as many architectural levels as possible. Finally, an expert system will continuously analyze the information from the radiation sensor and correlate it with historical data from the tag location in order to generate an alarm when an abnormal situation is detected. The system will be useful for many different scenarios, including such lost radioactive sources and radioactive contamination. It will be possible to deploy in emergency units and in general in any type of mobile or static equipment. The sensing units will be highly portable thanks to their low size and low energy consumption. The complete system will be scalable in terms of complexity and cost and will offer very high precision on both the measurement and the location of the radiation. The modularity and flexibility of the system will allow for a realistic introduction to the market. Authorities may start with a

  12. The research reactor radiation emergency countermeasure system in Korea

    Kim, Hee Reyoung; Choi, Geun-Sik; Lee, Wanno; Chung, Kun Ho; Kang, Mun Ja; Lee, Chang-Woo

    2010-01-01

    A disaster prevention system was established for a radiation emergency from an operation of a research reactor with a thermal power of 30 MW th in Korea. A national radiation disaster countermeasure organization was set up to cope with the radiation emergency classified into three cases whose effective doses were more than 1 mSv/h inside the nuclear facility, inside the site boundary and outside the site boundary. Its role consists of the proclamation and consequent withdrawal of a disaster, a general assessment, an emergency medical service, a field control, radiation protection, resident protection implement, an accident analysis, a security plan, a radiation environmental investigation plan and probe, a radiation environmental effect assessment, and others. The emergency planning zone (EPZ) was settled to be within a radius of 800 m, the average distance between the site boundary and the center of a research reactor in operation, as a quick and effective early countermeasure from the result of the radiation environmental effect assessment. The environmental probing zone was chosen to extend to a radius of 2 km from a research reactor according to the moving path of the radioactive cloud so that a densely populated area could be considered and would be extended to 10 km according to the radiation level of the research reactor and atmospheric diffusion. Practically, the environmental probing is implemented at 22 points inside the site and eight points outside the site considering the geography, population and the wind direction. The gamma radiation dose and atmospheric radioactivity are analyzed during an effluence, and the radioactivity of a ground surface deposit and an environmental sample are analyzed after an effluence. The environmental laboratory covers the analysis of the gamma radioisotopes, tritium, strontium, uranium, gross alpha and beta. It is estimated that the habitability can be recovered when the radiation dose rate is less than 1 mSv/h inside the

  13. GPU Nuclear Corporation's radiation exposure management system

    Slobodien, M.J.; Bovino, A.A.; Perry, O.R.; Hildebrand, J.E.

    1984-01-01

    GPU Nuclear Corporation has developed a central main frame (IBM 3081) based radiation exposure management system which provides real time and batch transactions for three separate reactor facilities. The structure and function of the data base are discussed. The system's main features include real time on-line radiation work permit generation and personnel exposure tracking; dose accountability as a function of system and component, job type, worker classification, and work location; and personnel dosemeter (TLD and self-reading pocket dosemeters) data processing. The system also carries the qualifications of all radiation workers including RWP training, respiratory protection training, results of respirator fit tests and medical exams. A warning system is used to prevent non-qualified persons from entering controlled areas. The main frame system is interfaced with a variety of mini and micro computer systems for dosemetry, statistical and graphics applications. These are discussed. Some unique dosemetry features which are discussed include assessment of dose for up to 140 parts of the body with dose evaluations at 7,300 and 1000 mg/cm 2 for each part, tracking of MPC hours on a 7 day rolling schedule; automatic pairing of TLD and self-reading pocket dosemeter values, creation and updating of NRC Forms 4 and 5, generation of NRC required 20.407 and Reg Guide 1.16 reports. As of July 1983, over 20 remote on-line stations were in use with plans to add 20-30 more by May 1984. The system provides response times for on-line activities of 2-7 seconds and 23 1/2 hours per day ''up time''. Examples of the various on-line and batch transactions are described

  14. Radiation mapping of Jaipur city using compact aerial radiation monitoring system (CARMS) installed in mobile platform

    Jain, Amit; Chaudhury, Probal; Padmanabhan, N.; Pradeepkumar, K.S.; Sharma, D.N.; Thandra, Manu

    2010-01-01

    Full text: Widespread use of radioisotopes for social benefits through industrial, scientific and medical applications poses a potential for occurrence of radiological emergencies due to loss or misuse of the radioactive sources. Besides, as there is increased societal concern for radiation safety of man and environment, monitoring is needed as a confidence building measure. It is necessary to assess any possible increase in background radiation due to the operation of nuclear facilities or any other man made events. Any observable increase in normal radiation background is a precursor for the abnormal presence of radioactivity. As a part of emergency preparedness for response to radiological emergencies, BARC has taken up radiation mapping of all major cities. A mobile ground based radiation monitoring has been conducted around Jaipur city using state-of-the-art radiation monitoring systems and instruments. The systems were mounted in a vehicle at a height of 1.0 meter from the ground and the GPS antenna was mounted on top for clear satellite visibility. It was ensured that the gamma attenuation due to the body of the vehicle was minimal. The average speed of the vehicle was maintained at 30 km/h to ensure uniformity in distance during the data acquisition interval. The monitoring was carried out over two days and resulted in establishment of baseline dose rate data of the city, which will be useful in case of any radiological emergency. The detailed environmental radiation monitoring demonstrated the utility of the systems and the methodology for the assessment of large area ground contamination and also search and detection of any orphan radioactive sources through variations in background gamma radiation observations. The methodology adopted for analysis of the surveyed data is based on the interpretation of the changes in the mean value and standard deviation in the values in different regions of the surveyed area. During this monitoring exercise, total road

  15. Radiation management system for the HIMAC

    Kono, Toshiyuki; Matsumoto, Takashi; Namiki, Hidefumi.

    1994-01-01

    In recent years, cancer is the worst cause of death. In order to exterminate cancer, the National Institute of Radiological Sciences has built HIMAC (Heavy Ion Medical Accelerator in Chiba). This plant can destroy the cells of cancer directly by irradiation of accelerated heavy ion beams such as Helium, Carbon, and Neon. Because those can intensively irradiate just the cell of cancer without destroying the other cells, this plant is especially effective to treat the pancreas cancer and brain tumor, which had been hard to treat. As this is the first plant in the world, exclusively for the medical use, we must try to experiment many times in order to call this plant 'the Saver'. The Radiation Safety Management System, in this report, was designed, producted and delivered by Fuji Electric Co., which has many achievements of the radiation management system for nuclear power plants and other radioisotope handling facilities. (author)

  16. Drug delivery system and radiation therapy

    Shibata, Tokushi

    2005-01-01

    This paper describes the review of radiation therapy, neutron capture therapy (NCT) and drug delivery system for the latter. In cancer radiation therapy, there are problems of body movement like breathing, needless irradiation of normal tissues, difficulty to decide the correct irradiation position and tumor morphology. NCT has advantages to overcome these, and since boron has a big cross section for thermal neutron, NPT uses the reaction 10 B(n, α) 7 Li in the target cancer which previously incorporated the boron-containing drug. During the period 1966-1996, 246 patients were treated with this in Japan and the treatment has been continued thereafter. The tasks for NCT are developments of drug delivery system efficient to deliver the drug into the tumor and of convenient neutron source like the accelerator. (S.I.)

  17. Telepositional portable real time radiation monitoring system

    Talpalariu, Jeni; Matei, Corina; Popescu, Oana

    2010-01-01

    Technology development for complex portable networks is on going to meet the area dosimetry challenge, improving the basic design using new telepositional GPS satellite methods and GSM terrestrial civil radio transmission networks. The system and devices proposed overcome the limitations of fixed and portable dosimeters, providing wireless real time radiations data and geospatial information's means, using many portable dosimeter stations and a mobile dosimeter computerised central console. (authors)

  18. Multichannel Digital Emulator of Radiation Detection Systems

    Abba, A.; Caponio, F.; Geraci, A.

    2013-06-01

    A digital system for emulating in real time signals from generic setups for radiation detection is presented. The instrument is not a pulse generator of recorded shapes but a synthesizer of random pulses compliant to programmable statistics for energy and occurrence time. Completely programmable procedures for emulation of noise, disturbances and reference level variation can be implemented. The instrument has been realized and fully tested. (authors)

  19. An amplitude analysis of the K bar K and π+π- systems (M 2) produced in J/ψ radiative decay

    Chen, Liang-Ping

    1991-10-01

    A mass independent amplitude of the K bar K and π + π - systems (M 2 ) produced in J/ψ radiative decay is presented. For the first time a large spin zero component in the θ(1720) mass region is observed, with all data samples analyzed. A small amount of spin two component in this mass region for the K bar K data samples is not ruled out with the present statistics. This study reveals, also for the first time, the production of the f o (1400) in the π + π - channel, and refines previous measurements of the f 2 (1270) and f' 2 (1525). 13 refs., 2 figs., 2 tabs

  20. GammaCam trademark radiation imaging system

    1998-02-01

    GammaCam trademark, a gamma-ray imaging system manufactured by AIL System, Inc., would benefit a site that needs to locate radiation sources. It is capable of producing a two-dimensional image of a radiation field superimposed on a black and white visual image. Because the system can be positioned outside the radiologically controlled area, the radiation exposure to personnel is significantly reduced and extensive shielding is not required. This report covers the following topics: technology description; performance; technology applicability and alternatives; cost; regulatory and policy issues; and lessons learned. The demonstration of GammaCam trademark in December 1996 was part of the Large-Scale Demonstration Project (LSDP) whose objective is to select and demonstrate potentially beneficial technologies at the Argonne National Laboratory-East (ANL) Chicago Pile-5 Research Reactor (CP-5). The purpose of the LSDP is to demonstrate that by using innovative and improved decontamination and decommissioning (D and D) technologies from various sources, significant benefits can be achieved when compared to baseline D and D technologies

  1. START: an advanced radiation therapy information system.

    Cocco, A; Valentini, V; Balducci, M; Mantello, G

    1996-01-01

    START is an advanced radiation therapy information system (RTIS) which connects direct information technology present in the devices with indirect information technology for clinical, administrative, information management integrated with the hospital information system (HIS). The following objectives are pursued: to support decision making in treatment planning and functional and information integration with the rest of the hospital; to enhance organizational efficiency of a Radiation Therapy Department; to facilitate the statistical evaluation of clinical data and managerial performance assessment; to ensure the safety and confidentiality of used data. For its development a working method based on the involvement of all operators of the Radiation Therapy Department, was applied. Its introduction in the work activity was gradual, trying to reuse and integrate the existing information applications. The START information flow identifies four major phases: admission, visit of admission, planning, therapy. The system main functionalities available to the radiotherapist are: clinical history/medical report linking function; folder function; planning function; tracking function; electronic mail and banner function; statistical function; management function. Functions available to the radiotherapy technician are: the room daily list function; management function: to the nurse the following functions are available: patient directing function; management function. START is a departmental client (pc-windows)-server (unix) developed on an integrated database of all information of interest (clinical, organizational and administrative) coherent with the standard and with a modular architecture which can evolve with additional functionalities in subsequent times. For a more thorough evaluation of its impact on the daily activity of a radiation therapy facility, a prolonged clinical validation is in progress.

  2. Radiation monitoring system based on Internet

    Drndarevic, V.R.; Popovic, A.T; Bolic, M.D.; Pavlovic, R.S.

    2001-01-01

    This paper presents concept and realization of the modern distributed radiation monitoring system. The system uses existing conventional computer network and it is based on the standard Internet technology. One personal computer (PC) serves as host and system server, while a number of client computers, link to the server computer via standard local area network (LAN), are used as distributed measurement nodes. The interconnection between the server and clients are based on Transmission Control Protocol/Internet Protocol (TCP/IP). System software is based on server-client model. Based on this concept distributed system for gamma ray monitoring in the region of the Institute of Nuclear Sciences Vinca has been implemented. (author)

  3. Radiation Counting System Software Using Visual Basic

    Nanda Nagara; Didi Gayani

    2009-01-01

    It has been created a Gamma Radiation Counting System using interface card, which paired with Personal Computer (PC) and operated by the Visual Basic program. The program was set through varied menu selections such as ”Multi Counting” , ”Counting and Record” and ”View Data”. An interface card for data acquisition was formed by using AMD9513 components as a counter and timer which can be programmed. This counting system was tested and used in waste facility in PTNBR and the result is quite good. (author)

  4. 71: Three dimensional radiation treatment planning system

    Purdy, J.A.; Wong, J.W.; Harms, W.B.; Drzymala, R.E.; Emami, B.

    1987-01-01

    A prototype 3-dimensional (3-D) radiation treatment planning (RTP) system has been developed and is in use. The system features a real-time display device and an array processor for computer intensive computations. The dose distribution can be displayed as 2-D isodose distributions superimposed on 2-D gray scale images of the patient's anatomy for any arbitrary plane and as a display of isodose surfaces in 3-D. In addition, dose-volume histograms can be generated. 7 refs.; 2 figs

  5. Radiation risk analysis of tritium in PWR plants

    Yang Maochun; Wang Shimin

    1999-03-01

    Tritium is a common radionuclide in PWR nuclear power plant. In the normal operation conditions, its radiation risk to plant workers is the internal radiation exposure when tritium existing in air as HTO (hydrogen tritium oxide) is breathed in. As the HTO has the same physical and chemical characteristics as water, the main way that HTO entering the air is by evaporation. There are few opening systems in Nuclear Power Plant, the radiation risk of tritium mainly exists near the area of spent fuel pit and reactor pit. The highest possible radiation risk it may cause--the maximum concentration in air is the level when equilibrium is established between water and air phases for tritium. The author analyzed the relationship among the concentration of HTO in water, in air and the water temperature when equilibrium is established, the equilibrated HTO concentration in air increases with HTO concentration in water and water temperature. The analysis revealed that at 30 degree C, the equilibrated HTO concentration in air might reach 1 DAC (derived air concentration) when the HTO concentration in water is 28 GBq/m 3 . Owing to the operation of plant ventilation systems and the existence of moisture in the input air of the ventilation, the practical tritium concentration in air is much lower than its equilibrated levels, the radiation risk of tritium in PWR plant is quite limited. In 1997, Daya Bay Nuclear Power Plant's practical monitoring result of the HTO concentration in the air of the nuclear island and the urine of workers supported this conclusion. Based on this analysis, some suggestions to the reduction of tritium radiation risk were made

  6. 47 CFR 22.383 - In-building radiation systems.

    2010-10-01

    ... MOBILE SERVICES Operational and Technical Requirements Technical Requirements § 22.383 In-building radiation systems. Licensees may install and operate in-building radiation systems without applying for... 47 Telecommunication 2 2010-10-01 2010-10-01 false In-building radiation systems. 22.383 Section...

  7. SORIS-A standoff radiation imaging system

    Zelakiewicz, Scott; Hoctor, Ralph; Ivan, Adrian; Ross, William; Nieters, Edward; Smith, William; McDevitt, Daniel; Wittbrodt, Michael; Milbrath, Brian

    2011-01-01

    The detection of radiological and special nuclear material within the country's borders is a crucial component of the national security network. Being able to detect small amounts of radiological material at large distances is especially important for search applications. To provide this capability General Electric's Research Center has developed, as a part of DNDO's standoff radiation detection system advanced technology demonstration (SORDS-ATD) program, a standoff radiation imaging system (SORIS). This vehicle-based system is capable of detecting weak sources at large distances in relatively short times. To accomplish this, GE has developed a novel coded aperture detector based on commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.

  8. SORIS—A standoff radiation imaging system

    Zelakiewicz, Scott; Hoctor, Ralph; Ivan, Adrian; Ross, William; Nieters, Edward; Smith, William; McDevitt, Daniel; Wittbrodt, Michael; Milbrath, Brian

    2011-10-01

    The detection of radiological and special nuclear material within the country's borders is a crucial component of the national security network. Being able to detect small amounts of radiological material at large distances is especially important for search applications. To provide this capability General Electric's Research Center has developed, as a part of DNDO's standoff radiation detection system advanced technology demonstration (SORDS-ATD) program, a standoff radiation imaging system (SORIS). This vehicle-based system is capable of detecting weak sources at large distances in relatively short times. To accomplish this, GE has developed a novel coded aperture detector based on commercial components from GE Healthcare. An array of commercial gamma cameras modified to increase the system efficiency and energy range are used as position sensitive detectors. Unlike typical coded aperture systems, however, SORIS employs a non-planar mask and thus does not suffer the typical limitations of partially encoded regions giving it a wide field of view. Source identification is done using both low-statistics anomaly indicators and conventional high-statistics algorithms being developed by Pacific Northwest National Laboratory. The results of scanned areas and threats identified are displayed to the user and overlaid on satellite imagery.

  9. Automatic actinometric system for diffuse radiation measurement

    Litwiniuk, Agnieszka; Zajkowski, Maciej

    2015-09-01

    Actinometric station is using for measuring solar of radiation. The results are helpful in determining the optimal position of solar panels relative to the Sun, especially in today's world, when the energy coming from the Sun and other alternative sources of energy become more and more popular. Polish climate does not provide as much energy as in countries in southern Europe, but it is possible to increase the amount of energy produced by appropriate arrangement of photovoltaic panels. There is the possibility of forecasting the amount of produced energy, the cost-effectiveness and profitability of photovoltaic installations. This implies considerable development opportunities for domestic photovoltaic power plants. This article presents description of actinometric system for diffuse radiation measurement, which is equipped with pyranometer - thermopile temperature sensor, amplifier AD620, AD Converter ADS1110, microcontroller Atmega 16, SD card, GPS module and LCD screen.

  10. Modification of GNPS environment radiation monitoring network system

    Jiang Lili; Cao Chunsheng

    1999-01-01

    GNPS Environment Radiation Continuous Monitoring System (KRS), the only real time on-line system of site radiation monitoring, was put into service in 1993 prior to the first loading the the plant. It is revealed through several years of operation that this system has some deficiencies such as inadequate real time monitoring means, no figure and diagram display function on the central computer, high failures, frequent failure warning signals, thus making the availability of the system at a low level. In recent years, with the rapid development of computer network technology and increasingly strict requirements on the NPP environment protection raised by the government and public, KRS modification had become necessary and urgent. In 1996, GNPS carried out modification work on the measuring geometry condition of γ radiation monitoring sub-station and lightening protection. To enhance the functions of real time monitoring and data auto-processing, further modification of the system was made in 1998, including the update of the software and hardware of KRS central processor, set-up of system computer local network and database. In this way, the system availability and monitoring quality are greatly improved and effective monitoring and analysis means are provided for gaseous release during normal operation and under accident condition

  11. System analysis for radwaste management

    Lennemann, W.L.

    1987-01-01

    The most logical approach to evaluating radioactive waste management processes and their options is to consider radioactive waste management, handling, and disposal as a complete and complex system from the waste arisings to their disposition. The principal elements that should be considered or taken into account when making a decision involving one or more components of a radwaste management system essentially concern radiation doses or detriments- both radiological and industrial safety and both capital investments and operating costs. This paper discusses the system analysis of the low- and medium-level radioactive waste management

  12. Spectral modeling of radiation in combustion systems

    Pal, Gopalendu

    Radiation calculations are important in combustion due to the high temperatures encountered but has not been studied in sufficient detail in the case of turbulent flames. Radiation calculations for such problems require accurate, robust, and computationally efficient models for the solution of radiative transfer equation (RTE), and spectral properties of radiation. One more layer of complexity is added in predicting the overall heat transfer in turbulent combustion systems due to nonlinear interactions between turbulent fluctuations and radiation. The present work is aimed at the development of finite volume-based high-accuracy thermal radiation modeling, including spectral radiation properties in order to accurately capture turbulence-radiation interactions (TRI) and predict heat transfer in turbulent combustion systems correctly and efficiently. The turbulent fluctuations of temperature and chemical species concentrations have strong effects on spectral radiative intensities, and TRI create a closure problem when the governing partial differential equations are averaged. Recently, several approaches have been proposed to take TRI into account. Among these attempts the most promising approaches are the probability density function (PDF) methods, which can treat nonlinear coupling between turbulence and radiative emission exactly, i.e., "emission TRI". The basic idea of the PDF method is to treat physical variables as random variables and to solve the PDF transport equation stochastically. The actual reacting flow field is represented by a large number of discrete stochastic particles each carrying their own random variable values and evolving with time. The mean value of any function of those random variables, such as the chemical source term, can be evaluated exactly by taking the ensemble average of particles. The local emission term belongs to this class and thus, can be evaluated directly and exactly from particle ensembles. However, the local absorption term

  13. Dynamic linearization system for a radiation gauge

    Panarello, J.A.

    1977-01-01

    The linearization system and process converts a high resolution non-linear analog input signal, representative of the thickness of an object, into a high resolution linear analog output signal suitable for use in driving a variety of output devices. The system requires only a small amount of memory for storing pre-calculated non-linear correction coefficients. The system channels the input signal to separate circuit paths so that it may be used directly to; locate an appropriate correction coefficient; develop a correction term after an appropriate correction coefficient is located; and develop a linearized signal having the same high resolution inherent in the input signal. The system processes the linearized signal to compensate for the possible errors introduced by radiation source noise. The processed linearized signal is the high resolution linear analog output signal which accurately represents the thickness of the object being gauged

  14. Portable radiation detector and mapping system

    Hofstetter, K.J.; Hayes, D.W.; Eakle, R.F.

    1995-01-01

    A portable radiation detector and mapping system (RADMAPS) has been developed to detect, locate and plot nuclear radiation intensities on commercially available digital maps and other images. The field unit records gamma-ray spectra or neutron signals together with positions from a Global Positioning System (GPS) on flash memory cards. The recorded information is then transferred to a lap-top computer for spectral data analyses and then georegistered graphically on maps, photographs, etc. RADMAPS integrates several existing technologies to produce a preprogrammable field unit uniquely suited for each survey, as required. The system presently records spectra from a Nal(Tl) gamma-ray detector or an enriched Li-6 doped glass neutron scintillator. Standard Geographic Information System software installed in a lap-top, complete with CD-ROM supporting digitally imaged maps, permits the characterization of nuclear material in the field when the presence of such material is not otherwise documented. This paper gives the results of a typical site survey of the Savannah River Site (SRS) using RADMAPS

  15. Geographic Analysis of the Radiation Oncology Workforce

    Aneja, Sanjay; Smith, Benjamin D.; Gross, Cary P.; Wilson, Lynn D.; Haffty, Bruce G.; Roberts, Kenneth; Yu, James B.

    2012-01-01

    Purpose: To evaluate trends in the geographic distribution of the radiation oncology (RO) workforce. Methods and Materials: We used the 1995 and 2007 versions of the Area Resource File to map the ratio of RO to the population aged 65 years or older (ROR) within different health service areas (HSA) within the United States. We used regression analysis to find associations between population variables and 2007 ROR. We calculated Gini coefficients for ROR to assess the evenness of RO distribution and compared that with primary care physicians and total physicians. Results: There was a 24% increase in the RO workforce from 1995 to 2007. The overall growth in the RO workforce was less than that of primary care or the overall physician workforce. The mean ROR among HSAs increased by more than one radiation oncologist per 100,000 people aged 65 years or older, from 5.08 per 100,000 to 6.16 per 100,000. However, there remained consistent geographic variability concerning RO distribution, specifically affecting the non-metropolitan HSAs. Regression analysis found higher ROR in HSAs that possessed higher education (p = 0.001), higher income (p < 0.001), lower unemployment rates (p < 0.001), and higher minority population (p = 0.022). Gini coefficients showed RO distribution less even than for both primary care physicians and total physicians (0.326 compared with 0.196 and 0.292, respectively). Conclusions: Despite a modest growth in the RO workforce, there exists persistent geographic maldistribution of radiation oncologists allocated along socioeconomic and racial lines. To solve problems surrounding the RO workforce, issues concerning both gross numbers and geographic distribution must be addressed.

  16. Geographic Analysis of the Radiation Oncology Workforce

    Aneja, Sanjay [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT (United States); Cancer Outcomes, Policy, and Effectiveness Research Center at Yale, New Haven, CT (United States); Smith, Benjamin D. [University of Texas M. D. Anderson Cancer Center, Houston, TX (United States); Gross, Cary P. [Cancer Outcomes, Policy, and Effectiveness Research Center at Yale, New Haven, CT (United States); Department of General Internal Medicine, Yale University School of Medicine, New Haven, CT (United States); Wilson, Lynn D. [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT (United States); Haffty, Bruce G. [Cancer Institute of New Jersey, New Brunswick, NJ (United States); Roberts, Kenneth [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT (United States); Yu, James B., E-mail: james.b.yu@yale.edu [Department of Therapeutic Radiology, Yale University School of Medicine, New Haven, CT (United States); Cancer Outcomes, Policy, and Effectiveness Research Center at Yale, New Haven, CT (United States)

    2012-04-01

    Purpose: To evaluate trends in the geographic distribution of the radiation oncology (RO) workforce. Methods and Materials: We used the 1995 and 2007 versions of the Area Resource File to map the ratio of RO to the population aged 65 years or older (ROR) within different health service areas (HSA) within the United States. We used regression analysis to find associations between population variables and 2007 ROR. We calculated Gini coefficients for ROR to assess the evenness of RO distribution and compared that with primary care physicians and total physicians. Results: There was a 24% increase in the RO workforce from 1995 to 2007. The overall growth in the RO workforce was less than that of primary care or the overall physician workforce. The mean ROR among HSAs increased by more than one radiation oncologist per 100,000 people aged 65 years or older, from 5.08 per 100,000 to 6.16 per 100,000. However, there remained consistent geographic variability concerning RO distribution, specifically affecting the non-metropolitan HSAs. Regression analysis found higher ROR in HSAs that possessed higher education (p = 0.001), higher income (p < 0.001), lower unemployment rates (p < 0.001), and higher minority population (p = 0.022). Gini coefficients showed RO distribution less even than for both primary care physicians and total physicians (0.326 compared with 0.196 and 0.292, respectively). Conclusions: Despite a modest growth in the RO workforce, there exists persistent geographic maldistribution of radiation oncologists allocated along socioeconomic and racial lines. To solve problems surrounding the RO workforce, issues concerning both gross numbers and geographic distribution must be addressed.

  17. Analysis of radiation measurement data of the BUSS cask

    Liu, Y.Y.; Tang, J.S.

    1995-01-01

    The Beneficial Uses Shipping System (BUSS) is a Type-B packaging developed for shipping nonfissile, special-form radioactive materials to facilities such as sewage, food, and medical-product irradiators. The primary purpose of the BUSS cask is to provide shielding and confinement, as well as impact, puncture, and thermal protection for its certified special-form contents under both normal transport and hypothetical accident conditions. A BUSS cask that contained 16 CsCl capsules (2.723 x 10 4 TBq total activity) was recently subjected to radiation survey measurements at a Westinghouse Hanford facility, which provided data that could be used to validate computer codes. Two shielding analysis codes, MICROSHIELD (User's Manual 1988) and SAS4 (Tan 1993), that are used at Argonne National Laboratory to evaluate the safety of packaging of radioactive materials during transportation, have been selected for analysis of radiation data obtained from the BUSS cask. MICROSHIELD, which performs only gamma radiation shielding calculation, is based on a point-kernel model with idealized geometry, whereas SAS4 is a control module in the SCALE code system (1995) that can perform three-dimensional Monte Carlo shielding calculation for photons and neutrons, with built-in procedures for cross-section data processing and automated variance reduction. The two codes differ in how they model the details of the physics of gamma photon attenuation in materials, and this difference is reflected in the associated engineering cost of the analysis. One purpose of the analysis presented in this paper, therefore, is to examine the effects of the major modeling assumptions in the two codes on calculated dose rates, and to use the measured dose rates for comparison. The focus in this paper is on analysis of radiation dose rates measured on the general body of the cask and away from penetrations

  18. Dosimetric analysis of radiation sources for use dermatological lesions

    Tada, Ariane

    2010-01-01

    Skin lesions undergoing therapy with radiation sources may have different patterns of malignancy. Malignant lesions or cancer most commonly found in radiotherapy services are carcinomas. Radiation therapy in skin lesions is performed with low penetration beams and orthovoltage X-rays, electron beams and radioactive sources ( 192 Ir, 198 Au, e 90 Sr) arranged on a surface mold or in metal applicator. This study aims to analyze the therapeutic radiation dose profile produced by radiation sources used in skin lesions radiotherapy procedures . Experimental measurements for the analysis of dosimetric radiation sources were compared with calculations obtained from a computer system based on the Monte Carlo Method. Computational results had a good agreement with the experimental measurements. Experimental measurements and computational results by the MCNP4C code were both physically consistent as expected. These experimental measurements compared with calculations using the MCNP-4C code have been used to validate the calculations obtained by MCNP code and to provide a reliable medical application for each clinical case. (author)

  19. Establishment of Database System for Radiation Oncology

    Kim, Dae Sup; Lee, Chang Ju; Yoo, Soon Mi; Kim, Jong Min; Lee, Woo Seok; Kang, Tae Young; Back, Geum Mun; Hong, Dong Ki; Kwon, Kyung Tae

    2008-01-01

    To enlarge the efficiency of operation and establish a constituency for development of new radiotherapy treatment through database which is established by arranging and indexing radiotherapy related affairs in well organized manner to have easy access by the user. In this study, Access program provided by Microsoft (MS Office Access) was used to operate the data base. The data of radiation oncology was distinguished by a business logs and maintenance expenditure in addition to stock management of accessories with respect to affairs and machinery management. Data for education and research was distinguished by education material for department duties, user manual and related thesis depending upon its property. Registration of data was designed to have input form according to its subject and the information of data was designed to be inspected by making a report. Number of machine failure in addition to its respective repairing hours from machine maintenance expenditure in a period of January 2008 to April 2009 was analyzed with the result of initial system usage and one year after the usage. Radiation oncology database system was accomplished by distinguishing work related and research related criteria. The data are arranged and collected according to its subjects and classes, and can be accessed by searching the required data through referring the descriptions from each criteria. 32.3% of total average time was reduced on analyzing repairing hours by acquiring number of machine failure in addition to its type in a period of January 2008 to April 2009 through machine maintenance expenditure. On distinguishing and indexing present and past data upon its subjective criteria through the database system for radiation oncology, the use of information can be easily accessed to enlarge the efficiency of operation, and in further, can be a constituency for improvement of work process by acquiring various information required for new radiotherapy treatment in real time.

  20. Comparison of the Effectiveness of Radiofrequency Ablation With Stereotactic Body Radiation Therapy in Inoperable Stage I Non-Small Cell Lung Cancer: A Systemic Review and Pooled Analysis

    Bi, Nan [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiation Oncology, Cancer Hospital and Institute, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing (China); Shedden, Kerby [Department of Biostatistics, University of Michigan, Ann Arbor, Michigan (United States); Zheng, Xiangpeng [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Kong, Feng-Ming, E-mail: fskong@iupui.edu [Department of Radiation Oncology, University of Michigan, Ann Arbor, Michigan (United States); Department of Radiation Oncology, Indiana University, Indianapolis (United States)

    2016-08-01

    Purpose: To performed a systematic review and pooled analysis to compare clinical outcomes of stereotactic body radiation therapy (SBRT) and radiofrequency ablation (RFA) for the treatment of medically inoperable stage I non-small cell lung cancer. Methods and Materials: A comprehensive literature search for published trials from 2001 to 2012 was undertaken. Pooled analyses were performed to obtain overall survival (OS) and local tumor control rates (LCRs) and adverse events. Regression analysis was conducted considering each study's proportions of stage IA and age. Results: Thirty-one studies on SBRT (2767 patients) and 13 studies on RFA (328 patients) were eligible. The LCR (95% confidence interval) at 1, 2, 3, and 5 years for RFA was 77% (70%-85%), 48% (37%-58%), 55% (47%-62%), and 42% (30%-54%) respectively, which was significantly lower than that for SBRT: 97% (96%-98%), 92% (91%-94%), 88% (86%-90%), and 86% (85%-88%) (P<.001). These differences remained significant after correcting for stage IA and age (P<.001 at 1 year, 2 years, and 3 years; P=.04 at 5 years). The effect of RFA was not different from that of SBRT on OS (P>.05). The most frequent complication of RFA was pneumothorax, occurring in 31% of patients, whereas that for SBRT (grade ≥3) was radiation pneumonitis, occurring in 2% of patients. Conclusions: Compared with RFA, SBRT seems to have a higher LCR but similar OS. More studies with larger sample sizes are warranted to validate such findings.

  1. Development of radiation detection and measurement systems

    Moon, B. S.; Ham, C. S.; Chung, C. E. and others

    2000-03-01

    This report contains descriptions on the following six items. The first item is the result of a study on CsI(TI) crystals with their light emitting characteristics and the result of a study on plastic scintillators. The second item is the result of a study on advanced radiation detectors and includes experiments for the effect of using a Compton suppressor with an HPGe detector. For the third item, we describe the results of a design work done using EGS4 for a thickness gauge, a density gauge, and a level gauge. The fourth item contains descriptions on the prototype circuit systems developed for a level gauge, a thickness gauge, and for a survey meter. The fifth part contains the computed tomography algorithm and a prototype scanning system developed for a CT system. As the sixth and the last item, we describe the prototype high precision heat source and the prototype heat-voltage converter which we have designed and fabricated.

  2. Development of radiation detection and measurement systems

    Moon, B. S.; Ham, C. S.; Chung, C. E. and others

    2000-03-01

    This report contains descriptions on the following six items. The first item is the result of a study on CsI(TI) crystals with their light emitting characteristics and the result of a study on plastic scintillators. The second item is the result of a study on advanced radiation detectors and includes experiments for the effect of using a Compton suppressor with an HPGe detector. For the third item, we describe the results of a design work done using EGS4 for a thickness gauge, a density gauge, and a level gauge. The fourth item contains descriptions on the prototype circuit systems developed for a level gauge, a thickness gauge, and for a survey meter. The fifth part contains the computed tomography algorithm and a prototype scanning system developed for a CT system. As the sixth and the last item, we describe the prototype high precision heat source and the prototype heat-voltage converter which we have designed and fabricated

  3. Radiative heat transfer in turbulent combustion systems theory and applications

    Modest, Michael F

    2016-01-01

    This introduction reviews why combustion and radiation are important, as well as the technical challenges posed by radiation. Emphasis is on interactions among turbulence, chemistry and radiation (turbulence-chemistry-radiation interactions – TCRI) in Reynolds-averaged and large-eddy simulations. Subsequent chapters cover: chemically reacting turbulent flows; radiation properties, Reynolds transport equation (RTE) solution methods, and TCRI; radiation effects in laminar flames; TCRI in turbulent flames; and high-pressure combustion systems. This Brief presents integrated approach that includes radiation at the outset, rather than as an afterthought. It stands as the most recent developments in physical modeling, numerical algorithms, and applications collected in one monograph.

  4. High Temperature Radiators for Electric Propulsion Systems, Phase I

    National Aeronautics and Space Administration — The VASIMR propulsion system uses a high temperature Loop Heat Pipe (LHP) radiator to reject heat from the helicon section. The current baseline radiator uses...

  5. A dual-sided coded-aperture radiation detection system

    Penny, R.D.; Hood, W.E.; Polichar, R.M.; Cardone, F.H.; Chavez, L.G.; Grubbs, S.G.; Huntley, B.P.; Kuharski, R.A.; Shyffer, R.T.; Fabris, L.; Ziock, K.P.; Labov, S.E.; Nelson, K.

    2011-01-01

    We report the development of a large-area, mobile, coded-aperture radiation imaging system for localizing compact radioactive sources in three dimensions while rejecting distributed background. The 3D Stand-Off Radiation Detection System (SORDS-3D) has been tested at speeds up to 95 km/h and has detected and located sources in the millicurie range at distances of over 100 m. Radiation data are imaged to a geospatially mapped world grid with a nominal 1.25- to 2.5-m pixel pitch at distances out to 120 m on either side of the platform. Source elevation is also extracted. Imaged radiation alarms are superimposed on a side-facing video log that can be played back for direct localization of sources in buildings in urban environments. The system utilizes a 37-element array of 5x5x50 cm 3 cesium-iodide (sodium) detectors. Scintillation light is collected by a pair of photomultiplier tubes placed at either end of each detector, with the detectors achieving an energy resolution of 6.15% FWHM (662 keV) and a position resolution along their length of 5 cm FWHM. The imaging system generates a dual-sided two-dimensional image allowing users to efficiently survey a large area. Imaged radiation data and raw spectra are forwarded to the RadioNuclide Analysis Kit (RNAK), developed by our collaborators, for isotope ID. An intuitive real-time display aids users in performing searches. Detector calibration is dynamically maintained by monitoring the potassium-40 peak and digitally adjusting individual detector gains. We have recently realized improvements, both in isotope identification and in distinguishing compact sources from background, through the installation of optimal-filter reconstruction kernels.

  6. Direct analysis of quantal radiation response data

    Thames, H.D. Jr.; Rozell, M.E.; Tucker, S.L.; Ang, K.K.; Travis, E.L.; Fisher, D.R.

    1986-01-01

    A direct analysis is proposed for quantal (all-or-nothing) responses to fractionated radiation and endpoint-dilution assays of cell survival. As opposed to two-step methods such as the reciprocal-dose technique, in which ED 50 values are first estimated for different fractionation schemes and then fit (as reciprocals) against dose per fraction, all raw data are included in a single maximum-likelihood treatment. The method accommodates variations such as short-interval fractionation regimens designed to determine tissue repair kinetics, tissue response to continuous exposures, and data obtained using endpoint-dilution assays of cell survival after fractionated doses. Monte-Carlo techniques were used to compare the direct and reciprocal-dose methods for analysis of small-scale and large-scale studies of response to fractionated doses. Both methods tended toward biased estimates in the analysis of small-scale (3 fraction numbers) studies. The α/β ratios showed less scatter when estimated by the direct method. The 95% confidence intervals determined by the direct method were more appropriate than those determined by reciprocal-dose analysis, for which 18% (small-scale study) or 8% (large-scale study) of the confidence intervals did not include the 'true' value of α/β. (author)

  7. Computerized radiation control system in the Chernobyl 30-km zone

    Vasil'chenko, D.L.; Pis'mak, A.D.; Livertovskij, G.P.; Chikhladze, V.S.

    1992-01-01

    Computerized radiation control system is intended for monitoring radiation in the zone of radiation-hazardous objects for providing nuclear power station services with current information on radiactive situation in the zone of observation and the doses of radiation taken by the personnel. Described are tasks and functions of the system, as well as its structure. It is noted that unique conditions of the Chernobyl' 30-km zone open up opportunities for experiments and testing new models of equipment. 2 figs

  8. Dosimetry systems for radiation processing in Japan

    Tamura, Naoyuki

    1995-01-01

    The present situation of dosimetry systems for radiation processing industry in Japan is reviewed. For gamma-rays irradiation the parallel-plate ionization chamber in TRCRE, JAERI has been placed as a reference standard dosimeter for processing-level dose. Various solid and liquid chemical dosimeters are used as routine dosimeters for gamma processing industries. Alanine dosimeters is used for the irradiation purpose which needs precise dosimetry. For electron-beam irradiation the electron current density meter and the total absorption calorimeter of TRCRE are used for the calibration of routine dosimeters. Plastic film dosimeters, such as cellulose triacetate and radiochromic dye are used as routine dosimeters for electron processing industries. When the official traceability systems for processing-level dosimetry now under investigation is completed, the ionization chamber of TRCRE is expected to have a role of the primary standard dosimeter and the specified alanine dosimeter will be nominated for the secondary or reference standard dosimeter. (author)

  9. Software for airborne radiation monitoring system

    Sheinfeld, M.; Kadmon, Y.; Tirosh, D.; Elhanany, I.; Gabovitch, A.; Barak, D.

    1997-01-01

    The Airborne Radiation Monitoring System monitors radioactive contamination in the air or on the ground. The contamination source can be a radioactive plume or an area contaminated with radionuclides. This system is composed of two major parts: Airborne Unit carried by a helicopter, and Ground Station carried by a truck. The Airborne software is intended to be the core of a computerized airborne station. The software is written in C++ under MS-Windows with object-oriented methodology. It has been designed to be user-friendly: function keys and other accelerators are used for vital operations, a help file and help subjects are available, the Human-Machine-Interface is plain and obvious. (authors)

  10. A novel mobile system for radiation detection and monitoring

    Biafore, Mauro

    2014-05-01

    evolving needs and budget constraints. On 24th September 2013, REWARD project received a prize as the best Innovative project related to the Not Conventional Threat (NCT) Chemical Biological Radiological Nuclear explosives (CBRNe) products. A highly distinguished jury stated that "the developed detection and surveillance system offers a perfect solution for end-users to enhance crucial capabilities in RN analysis, risk communication and surveillance in case of a radiation incident". A demonstration of the REWARD system is planned in Naples on September 2014. More information about the REWARD project can be found at www.reward-project.eu.

  11. Recent developments in the Los Alamos radiation transport code system

    Forster, R.A.; Parsons, K.

    1997-01-01

    A brief progress report on updates to the Los Alamos Radiation Transport Code System (LARTCS) for solving criticality and fixed-source problems is provided. LARTCS integrates the Diffusion Accelerated Neutral Transport (DANT) discrete ordinates codes with the Monte Carlo N-Particle (MCNP) code. The LARCTS code is being developed with a graphical user interface for problem setup and analysis. Progress in the DANT system for criticality applications include a two-dimensional module which can be linked to a mesh-generation code and a faster iteration scheme. Updates to MCNP Version 4A allow statistical checks of calculated Monte Carlo results

  12. Classification system for acute and chronic radiation treatment sequelae

    Seegenschmiedt, M.H.; Sauer, R.

    1993-01-01

    A classification system in German language is proposed for scoring of acute and chronic treatment sequelae after radiotherapy. It includes all important organs and organ systems. The proposed grading corresponds to the four-scale-system of the WHO and UICC. The system is also compatible to the RTOG and EORTC acute and late radiation morbidity scoring criteria. This facilitates the data transfer for retrospective and prospective analysis of monomodal and multimodal radiotherapy treatment regimes. We recommend to use this scoring system in all German speaking countries for multicentric prospective studies. It is possible, that organ-specific sophistications of the toxicity grading will be developed in the future. These additions should conform with (inter)national standards and apply the same four-scale grading of this classification system. (orig.) [de

  13. Radiation protection system in Azerbaijan Republic

    Aliyev, L.

    2002-01-01

    land or merge into Caspian See. Is increased also the bring into country of instruments, equipments and other technical means, which work on radioactive sources basic. The numerated facts indicate that is necessary function of good radiation control land protection's system in Azerbaijan (sector radiation's investigations, Radioecology Center NMS of Ministry for Ecology and Natural Recourses the special Plant 'Isotope' and his burring point of radioactive wastes, Civil Defense. Academic organizations and NMS, execute monitoring, control and noticing function by radiation situation. The last two organizations structures, which have been occupied with keeping, transportation, disactivate and burring of radioactive sources and their wastes, which are receiving here from much institutions. The functional activity of special plant 'Isotope' must be reorganized and reconstruct- red the exist PBRW. There is necessity of build of new PBRW, in according with modern technical requirements to the industrial cycle on complete utilization of all radioactive wastes kinds. The monitoring function of radiation situation over all territory of Republic is put on NMS MENR of Azerbaijan. But, for the execution his problems, NMS are necessary new instrumental park (radiometric, dozemetric, spectrometric and etc.) and the dense monitoring network over all territory of Azerbaijan Republic. Co-operation with IAEA will allow improve the quality of radiation protection system of Azerbaijan in shorter periods. (author)

  14. Networked gamma radiation detection system for tactical deployment

    Mukhopadhyay, Sanjoy; Maurer, Richard; Wolff, Ronald; Smith, Ethan; Guss, Paul; Mitchell, Stephen

    2015-08-01

    A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2″ × 4″ × 16″ sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

  15. 1D radiation analysis for the fusion ignition experiment ZEPHYR

    Brockmann, H.; Ohlig, U.; Krause, H.

    1979-11-01

    For the proposed tokamak ignition experiment ZEPHYR a nuclear radiation analysis is performed for both the prompt radiation during a discharge and the delayed radiation after discharges. This analysis is restricted to a one-dimensional geometrical approximation of the apparatus. Nuclear heating data are derived for the prompt radiation and the shielding concept is investigated. Results for the delayed radiation are given for three activation scenarios, that are anticipated for machine operation. The cooling phase after one of these scenarios is investigated in some detail in order to trace the dominant contributions to biological dose rates back to machine components and to specific activation reactions. (orig.)

  16. Radiation-hardened microwave communications system

    Smith, S.F.; Crutcher, R.I.; Vandermolen, R.I.

    1990-01-01

    The consolidated fuel reprocessing program (CFRP) at the Oak Ridge National Laboratory (ORNL) has been developing signal transmission techniques and equipment to improve the efficiency of remote handling operations for nuclear applications. These efforts have been largely directed toward the goals of (a) remotely controlling bilateral force-reflecting servomanipulators for dexterous manipulation-based operations in remote maintenance tasks and (b) providing television viewing of the work site. In September 1987, developmental microwave transceiving hardware operating with dish antennas was demonstrated in the advanced integrated maintenance system (AIMS) facility at ORNL, successfully implementing both high-quality one-way television transmissions and simultaneous bidirectional digital control data transmissions with very low error rates. Initial test results based on digital transmission at a 1.0-Mbaud data rate indicated that the error rates of the microwave system were comparable to those of a hardwired system. During these test intervals, complex manipulator operations were performed, and the AIMS transporter was moved repeatedly without adverse effects on data integrity. Results of these tests have been factored into subsequent phases of the development program, with an ultimate goal of designing a fully radiation-hardened microwave signal transmission system for use in nuclear facilities

  17. Systems engineering and analysis

    Blanchard, Benjamin S

    2010-01-01

    For senior-level undergraduate and first and second year graduate systems engineering and related courses. A total life-cycle approach to systems and their analysis. This practical introduction to systems engineering and analysis provides the concepts, methodologies, models, and tools needed to understand and implement a total life-cycle approach to systems and their analysis. The authors focus first on the process of bringing systems into being--beginning with the identification of a need and extending that need through requirements determination, functional analysis and allocation, design synthesis, evaluation, and validation, operation and support, phase-out, and disposal. Next, the authors discuss the improvement of systems currently in being, showing that by employing the iterative process of analysis, evaluation, feedback, and modification, most systems in existence can be improved in their affordability, effectiveness, and stakeholder satisfaction.

  18. Wind energy analysis system

    2014-01-01

    M.Ing. (Electrical & Electronic Engineering) One of the most important steps to be taken before a site is to be selected for the extraction of wind energy is the analysis of the energy within the wind on that particular site. No wind energy analysis system exists for the measurement and analysis of wind power. This dissertation documents the design and development of a Wind Energy Analysis System (WEAS). Using a micro-controller based design in conjunction with sensors, WEAS measure, calcu...

  19. Analysis of radiation overexposures for radiation workers in industrial institutions during 1991-1995

    Mahajan, J.M.; Raman, N.V.; Massand, O.P.

    1997-01-01

    Radiation Standards and Instrumentation Division (RS and ID) conducts country wide personnel monitoring service for external exposures of a total of about 41,000 radiation workers. Out of these, there are about 5300 radiation workers in industrial institutions alone. The analysis of overexposure cases (more than 10 mSv during a monitoring period) of these radiation workers has been presented for the period 1991-1995. The paper describes how the reporting, investigations and follow-up of these cases helps in obtaining effective control of doses to the radiation workers in the country keeping in view the dose limits stipulated by the Atomic Energy Regulatory Board. (author)

  20. Discussion on some problems in evolution of radiation protection system

    Pan Ziqiang

    2003-01-01

    In radiation protection practice in China, the appropriate simplification and better coordination for the existing radiation protection system are necessary. The human-based protective measures alone could not meet the requirements of the environmental protection in many circumstances. Protecting the environment from ionizing radiation would be implicated in radiation protection. Collective dose is an useful index, its applicable scope should be well defined. Using such an quantity can help increase radiation protection level, but applicable conditions should be defined, such as time and space. Natural radiation is the largest contributor of the radiation exposure to human. Occupational exposure from natural radiation should be controlled, such as to underground miners and air crew. Controlling both man-made and natural radiation exposure to pregnant women and children needs to be enhanced, especially radiological diagnosis and therapy

  1. Multi-sensor radiation detector system

    Foster, R.G.; Cyboron, R.D.

    1975-01-01

    The invention is a multi-sensor radiation detection system including a self-powered detector and an ion or fission chamber, preferably joined as a unitary structure, for removable insertion into a nuclear reactor. The detector and chamber are connected electrically in parallel, requiring but two conductors extending out of the reactor to external electrical circuitry which includes a load impedance, a voltage source, and switch means. The switch means are employed to alternately connect the detector and chamber either with th load impedance or with the load impedance and the voltage source. In the former orientation, current through the load impedance indicates flux intensity at the self-powered detector and in the latter orientation, the current indicates flux intensity at the detector and fission chamber, though almost all of the current is contributed by the fission chamber. (auth)

  2. Spectrometer system for diffuse extreme ultraviolet radiation

    Labov, Simon E.

    1989-01-01

    A unique grazing incidence spectrometer system has been designed to study diffuse line emission between 80 and 650 A with 10-30 A resolution. The minimum detectable emission line strength during a 5-min observation ranges from 100-2000 ph/sq cm sec str. The instrument uses mechanically ruled reflection gratings placed in front of a linear array of mirrors. These mirrors focus the spectral image on microchannel plate detectors located behind thin filters. The field of view is 40 min of arc by 15 deg, and there is no spatial imaging. This instrument has been fabricated, calibrated, and successfully flown on a sounding rocket to observe the astronomical background radiation.

  3. Scattered radiation in fan beam imaging systems

    Johns, P.C.; Yaffe, M.

    1982-01-01

    Scatter-to-primary energy fluence ratios (S/P) have been studied for fan x-ray beams as used in CT scanners and slit projection radiography systems. The dependence of S/P on phantom diameter, distance from phantom to image receptor, and kilovoltage is presented. An empirical equation is given that predicts S/P over a wide range of fan beam imaging configurations. For CT body scans on a 4th-generation machine, S/P is approximately 5%. Scattered radiation can produce a significant cupping artefact in CT images which is similar to that due to beam hardening. When multiple slices are used in scanned slit radiography, they can be arranged such that the increase in S/P is negligible. Calculations of scatter-to-primary ratios for first order scattering showed that for fan beams the contribution of coherent scatter is comparable to or greater than that of incoherent first scatter

  4. Optical camera system for radiation field

    Maki, Koichi; Senoo, Makoto; Takahashi, Fuminobu; Shibata, Keiichiro; Honda, Takuro.

    1995-01-01

    An infrared-ray camera comprises a transmitting filter used exclusively for infrared-rays at a specific wavelength, such as far infrared-rays and a lens used exclusively for infrared rays. An infrared ray emitter-incorporated photoelectric image converter comprising an infrared ray emitting device, a focusing lens and a semiconductor image pick-up plate is disposed at a place of low gamma-ray dose rate. Infrared rays emitted from an objective member are passed through the lens system of the camera, and real images are formed by way of the filter. They are transferred by image fibers, introduced to the photoelectric image converter and focused on the image pick-up plate by the image-forming lens. Further, they are converted into electric signals and introduced to a display and monitored. With such a constitution, an optical material used exclusively for infrared rays, for example, ZnSe can be used for the lens system and the optical transmission system. Accordingly, it can be used in a radiation field of high gamma ray dose rate around the periphery of the reactor container. (I.N.)

  5. Size determination of an equilibrium enzymic system by radiation inactivation

    Simon, P.; Swillens, S.; Dumont, J.E.

    1982-01-01

    Radiation inactivation of complex enzymic systems is currently used to determine the enzyme size and the molecular organization of the components in the system. An equilibrium model was simulated describing the regulation of enzyme activity by association of the enzyme with a regulatory unit. It is assumed that, after irradiation, the system equilibrates before the enzyme activity is assayed. The theoretical results show that the target-size analysis of these numerical data leads to a bad estimate of the enzyme size. Moreover, some implicit assumptions such as the transfer of radiation energy between non-covalently bound molecules should be verified before interpretation of target-size analysis. It is demonstrated that the apparent target size depends on the parameters of the system, namely the size and the concentration of the components, the equilibrium constant, the relative activities of free enzyme and enzymic complex, the existence of energy transfer, and the distribution of the components between free and bound forms during the irradiation. (author)

  6. Integrated evaluation of radiative heating systems for residential buildings

    Anastaselos, Dimitrios; Theodoridou, Ifigeneia; Papadopoulos, Agis M.; Hegger, Manfred

    2011-01-01

    Based on the need to reduce CO 2 emissions and minimize energy dependency, the EU Member States have set ambitious energy policies goals and have developed respective, specific regulations, in order to improve the energy performance of the building sector. Thus, specific measures regarding the buildings' envelope, the use of efficient HVAC technologies and the integration of renewable energy systems are being constantly studied and promoted. The effective combination of these three main aspects will consequently result in maximum energy efficiency. Germany has played a key role in this development, with intensive work focusing in the improvement of the energy behaviour of the residential building stock. In this paper, the use of radiative heating systems placing special emphasis on infrared is being studied as part of the energy renovation of residential buildings from the 1970's. This is done by applying an integrated assessment model to evaluate specific interventions regarding the improvement of the energy behaviour of the buildings' envelope and the use of radiative heating systems, based on a thorough Life Cycle Analysis according to criteria of energy, economic and environmental performance, as well as thermal comfort. -- Highlights: → Assessment of energy, economic and environmental performance of heating systems. → Life Cycle Analysis in combination with the quality of thermal comfort. → Effectiveness of interventions in already partially insulated buildings.

  7. solaR: Solar Radiation and Photovoltaic Systems with R

    Oscar Perpiñan Lamigueiro

    2012-08-01

    Full Text Available The solaR package allows for reproducible research both for photovoltaics (PV systems performance and solar radiation. It includes a set of classes, methods and functions to calculate the sun geometry and the solar radiation incident on a photovoltaic generator and to simulate the performance of several applications of the photovoltaic energy. This package performs the whole calculation procedure from both daily and intradaily global horizontal irradiation to the final productivity of grid-connected PV systems and water pumping PV systems.It is designed using a set of S4 classes whose core is a group of slots with multivariate time series. The classes share a variety of methods to access the information and several visualization methods. In addition, the package provides a tool for the visual statistical analysis of the performance of a large PV plant composed of several systems.Although solaR is primarily designed for time series associated to a location defined by its latitude/longitude values and the temperature and irradiation conditions, it can be easily combined with spatial packages for space-time analysis.

  8. RAM R-200 - A Portable Ruggedized Radiation Monitoring System

    Wengrowicz, U.; Mazor, T.; Assido, H.; Kadmon, Y.; Tirosh, D.; Shani, G.

    1999-01-01

    RAM R-200, a new generation of ruggedized portable radiation-monitoring systems, is presented. The system which is a result of interdisciplinary research, was developed at the NRCN in collaboration with Ben-Gurion University. It consists of RAM R-200 - a portable radiation meter, and a variety of external probes for wide range gamma radiation fields and beta-gamma contamination detection and measurement. The meter or each one of the external probes can be used as a portable system or a stand-alone radiation measurement station. All the system's components were specially designed to meet severe environmental conditions

  9. Solar Radiation Research Laboratory | Energy Systems Integration Facility |

    Solar Radiation Research Laboratory (SRRL) has been collecting continuous measurements of basic solar continuous operation. More than 75 instruments contribute to the Baseline Measurement System by recording

  10. Development of Nuclide Recognizing Prompt Radiation Distribution Monitoring System

    Lee, Uk Jae; Yoo, Dong Han; Kim, Hee Reyoung [Ulsan National Institute of Science and Technology, Ulsan (Korea, Republic of)

    2014-05-15

    The geographic data such as latitude, longitude and map image can be obtained by using GPS and digital map. Radiation data can be acquired by detector. Finally simultaneous visibility system can be operated by using CDMA. Existing radiation distribution monitoring system is based on random generated data. However the radiation distribution monitoring system is developed. It is based on real detected data. Connection between the detector and laptop which are located at a site place is operated by using Bluetooth. CDMA is used to simulate visibility system between laptop in a site place and server PC in the control office. Real map image is taken from digital map. Finally radiation distribution contour map on the real map image can be shown by using MATLAB. 5 figures appear which shows natural, {sup 137}Cs, {sup 131}I, artificial and total radiation dose rate. So this system can be used in everywhere to check the distribution of radiation with geographic information.

  11. Fiscal system analysis - contractual systems

    Kaiser, M.J.

    2006-01-01

    Production sharing contracts are one of the most popular forms of contractual system used in petroleum agreements around the world, but the manner in which the fiscal terms and contract parameters impact system measures is complicated and not well understood. The purpose of this paper is to quantify the influence of private and market uncertainty in contractual fiscal systems. A meta-modelling approach is employed that couples the results of a simulation model with regression analysis to construct numerical functionals that quantify the fiscal regime. Relationships are derived that specify how the present value, rate of return, and take statistics vary as a function of the system parameters. The deepwater Girassol field development in Angola is taken as a case study. (author)

  12. Occupational Radiation Exposure Analysis of US ITER DCLL TBM

    Merrill, Brad J; Cadwallader, Lee C; Dagher, Mohamad

    2007-08-01

    This report documents an Occupational Radiation Exposure (ORE) analysis that was performed for the US International Thermonuclear Experimental Reactor (ITER) Dual Coolant Lead Lithium (DCLL) Test Blanket Module (TBM). This analysis was performed with the QADMOD dose code for anticipated maintenance activities for this TBM concept and its ancillary systems. The QADMOD code was used to model the PbLi cooling loop of this TBM concept by specifying gamma ray source terms that simulated radioactive material within the piping, valves, heat exchanger, permeator, pump, drain tank, and cold trap of this cooling system. Estimates of the maintenance tasks that will have to be performed and the time required to perform these tasks where developed based on either expert opinion or on industrial maintenance experience for similar technologies. This report details the modeling activity and the calculated doses for the maintenance activities envisioned for the US DCLL TBM.

  13. Design of Kartini reactor radiation monitor system using lab view

    Adi Abimanyu; Jumari; Achmad Fahrul Aji; Muhammad Khoiri

    2014-01-01

    Kartini Reactor operation will result in radiation exposure. Gamma radiation exposure rate at the Kartini Reactor monitored by several radiation monitors (Ludlum) that integrate with the computer, so that the rate of radiation exposure is always monitored. Current monitoring system combines six radiation monitor in one computer monitor radiation, and monitoring performed by operators and supervisors to see how the radiation exposure rate measured in the area around the reactor core in a periodic time manually. This research will develop a system to monitor radiation exposure in Kartini reactor based ATMega8 micro controller for interface between radiation monitor and computer and also Graphical User Interface (GUI) develop using Lab view software that makes monitoring is easier and documented regularly. This system is testing by simulation, it is done by replacing the function of the radiation monitoring devices (Ludlum) in Kartini Reactor with computers that send serial data with the same format with a format that is sent by Ludlum. The results show that the interface system has the ability to operate in a range of baud rate 1,200 bps, 2,400 bps, 4,800 bps, 9,600 bps, 14,400 bps, 19,200 bps and 38,400 bps, with the ability to provide realtime information every 6 seconds and able to document the rate of exposure to radiation in the form of logbook. (author)

  14. Cost benefit analysis for optimization of radiation protection

    Lindell, B.

    1984-01-01

    ICRP recommends three basic principles for radiation protection. One is the justification of the source. Any use of radiation should be justified with regard to its benefit. The second is the optimization of radiation protection, i.e. all radiation exposure should be kept as low as resonably achievable. And the third principle is that there should be a limit for the radiation dose that any individual receives. Cost benefit assessment or cost benefit analysis is one tool to achieve the optimization, but the optimization is not identical with cost benefit analysis. Basically, in principle, the cost benefit analysis for the optimization of radiation protection is to find the minimum sum of the cost of protection and some cost of detriment. (Mori, K.)

  15. Effect of gamma radiation on graphite – PTFE dry lubrication system

    Singh, Sachin; Tyagi, Mukti; Seshadri, Geetha; Tyagi, Ajay Kumar; Varshney, Lalit

    2017-01-01

    An effect of gamma radiation on lubrication behavior of graphite -PTFE dry lubrication system has been studied using (TR-TW-30L) tribometer with thrust washer attachment in plane contact. Different compositions of graphite and PTFE were prepared and irradiated by gamma rays. Gamma radiation exposure significantly improves the tribological properties indicated by decrease in coefficient of friction and wear properties of graphite -PTFE dry lubrication system. SEM and XRD analysis confirm the physico-chemical modification of graphite-PTFE on gamma radiation exposure leading to a novel dry lubrication system with good slip and anti friction properties. - Highlights: • Novel dry lubrication system of graphite -PTFE using gamma radiation. • Gamma radiation processing. • Reduction in coefficient of friction, frictional torque and wear loss of developed dry lubrication system.

  16. Comprehensive Craniospinal Radiation for Controlling Central Nervous System Leukemia

    Walker, Gary V.; Shihadeh, Ferial; Kantarjian, Hagop; Allen, Pamela; Rondon, Gabriela; Kebriaei, Partow; O'Brien, Susan; Kedir, Aziza; Said, Mustefa; Grant, Jonathan D.; Thomas, Deborah A.; Gidley, Paul W.; Arzu, Isidora; Pinnix, Chelsea; Reed, Valerie; Dabaja, Bouthaina S.

    2014-01-01

    Purpose: To determine the benefit of radiation therapy (RT) in resolution of neurologic symptoms and deficits and whether the type of RT fields influences central nervous system (CNS) control in adults with CNS leukemia. Methods and Materials: A total of 163 adults from 1996 to 2012 were retrospectively analyzed. Potential associations between use of radiation and outcome were investigated by univariate and multivariate analysis. Results: The median survival time was 3.8 months after RT. Common presenting symptoms were headache in 79 patients (49%), cranial nerve VII deficit in 46 (28%), and cranial nerve II deficit in 44 (27%). RT was delivered to the base of skull in 48 patients (29%), to the whole brain (WB) in 67 (41%), and to the craniospinal axis (CS) in 48 (29%). Among 149 patients with a total of 233 deficits, resolution was observed in 34 deficits (15%), improvement in 126 deficits (54%), stability in 34 deficits (15%), and progression in 39 deficits (17%). The 12-month CNS progression-free survival was 77% among those receiving CS/WB and 51% among those receiving base of skull RT (P=.02). On multivariate analysis, patients who did not undergo stem cell transplantation after RT and base of skull RT were associated with worse CNS progression-free survival. Conclusions: Improvement or resolution of symptoms occurred in two thirds of deficits after RT. Comprehensive radiation to the WB or CS seems to offer a better outcome, especially in isolated CNS involvement

  17. Comprehensive Craniospinal Radiation for Controlling Central Nervous System Leukemia

    Walker, Gary V.; Shihadeh, Ferial [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kantarjian, Hagop [Department of Leukemia, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Allen, Pamela [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Rondon, Gabriela; Kebriaei, Partow [Department of Stem Cell Transplantation, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); O' Brien, Susan [Department of Leukemia, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Kedir, Aziza; Said, Mustefa; Grant, Jonathan D. [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Thomas, Deborah A. [Department of Leukemia, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Gidley, Paul W. [Department of Head and Neck Surgery, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Arzu, Isidora; Pinnix, Chelsea; Reed, Valerie [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States); Dabaja, Bouthaina S., E-mail: bdabaja@mdanderson.org [Department of Radiation Oncology, The University of Texas MD Anderson Cancer Center, Houston, Texas (United States)

    2014-12-01

    Purpose: To determine the benefit of radiation therapy (RT) in resolution of neurologic symptoms and deficits and whether the type of RT fields influences central nervous system (CNS) control in adults with CNS leukemia. Methods and Materials: A total of 163 adults from 1996 to 2012 were retrospectively analyzed. Potential associations between use of radiation and outcome were investigated by univariate and multivariate analysis. Results: The median survival time was 3.8 months after RT. Common presenting symptoms were headache in 79 patients (49%), cranial nerve VII deficit in 46 (28%), and cranial nerve II deficit in 44 (27%). RT was delivered to the base of skull in 48 patients (29%), to the whole brain (WB) in 67 (41%), and to the craniospinal axis (CS) in 48 (29%). Among 149 patients with a total of 233 deficits, resolution was observed in 34 deficits (15%), improvement in 126 deficits (54%), stability in 34 deficits (15%), and progression in 39 deficits (17%). The 12-month CNS progression-free survival was 77% among those receiving CS/WB and 51% among those receiving base of skull RT (P=.02). On multivariate analysis, patients who did not undergo stem cell transplantation after RT and base of skull RT were associated with worse CNS progression-free survival. Conclusions: Improvement or resolution of symptoms occurred in two thirds of deficits after RT. Comprehensive radiation to the WB or CS seems to offer a better outcome, especially in isolated CNS involvement.

  18. Radianttrademark Liquid Radioisotope Intravascular Radiation Therapy System

    Eigler, N.; Whiting, J.; Chernomorsky, A.; Jackson, J.; Knapp, F.F. Jr.; Litvack, F.

    1998-01-01

    RADIANTtrademark is manufactured by United States Surgical Corporation, Vascular Therapies Division, (formerly Progressive Angioplasty Systems). The system comprises a liquid β-radiation source, a shielded isolation/transfer device (ISAT), modified over-the-wire or rapid exchange delivery balloons, and accessory kits. The liquid β-source is Rhenium-188 in the form of sodium perrhenate (NaReO 4 ), Rhenium-188 is primarily a β-emitter with a physical half-life of 17.0 hours. The maximum energy of the β-particles is 2.1 MeV. The source is produced daily in the nuclear pharmacy hot lab by eluting a Tungsten-188/Rhenium-188 generator manufactured by Oak Ridge National Laboratory (ORNL). Using anion exchange columns and Millipore filters the effluent is concentrated to approximately 100 mCi/ml, calibrated, and loaded into the (ISAT) which is subsequently transported to the cardiac catheterization laboratory. The delivery catheters are modified Championtrademark over-the-wire, and TNTtrademark rapid exchange stent delivery balloons. These balloons have thickened polyethylene walls to augment puncture resistance; dual radio-opaque markers and specially configured connectors

  19. Gravitational radiation from nearly Newtonian systems

    Kirk, E.M.

    1989-09-01

    A method of examining gravitational radiation from nearly Newtonian systems is presented. Using the Cartan formulation of Newtonian gravity, a one parameter family of space-times which have a strict Newtonian limit is constructed. An expression for the initial null data in terms of the Newtonian potential is obtained in the Newtonian limit. Using this, the problem is formulated as a series in the Newtonian parameter. The series expansions for the sources of the Bianchi identities are obtained to third order in both the vacuum and non-vacuum cases. A simple technique is presented for determining whether a particular source term gives rise to asymptotically flat null data. The far field quadrupole formula is derived in a leading approximation and a method for obtaining error bounds is discussed. Additionally, a method for solving Einstein's equations is shown. This involves expressing the Ricci identities as a matrix, Riccati equation and a system of linear matrix equations. A comparison of the formalisms of Bondi and Newman Penrose is presented and explicit correspondences between the supersurface constrain equations and the Ricci identities are shown. (author)

  20. Untangling the methane chemistry in interstellar and solar system ices toward ionizing radiation: a combined infrared and reflectron time-of-flight analysis.

    Abplanalp, Matthew J; Jones, Brant M; Kaiser, Ralf I

    2018-02-21

    Pure methane (CH 4 /CD 4 ) ices were exposed to three ionizing radiation sources at 5.5 K under ultrahigh vacuum conditions to compare the complex hydrocarbon spectrum produced across several interstellar environments. These irradiation sources consisted of energetic electrons to simulate secondary electrons formed in the track of galactic cosmic rays (GCRs), Lyman α (10.2 eV; 121.6 nm) photons simulated the internal VUV field in a dense cloud, and broadband (112.7-169.8 nm; 11.0-7.3 eV) photons which mimic the interstellar ultra-violet field. The in situ chemical evolution of the ices was monitored via Fourier transform infrared spectroscopy (FTIR) and during heating via mass spectrometry utilizing a quadrupole mass spectrometer with an electron impact ionization source (EI-QMS) and a reflectron time-of-flight mass spectrometer with a photoionization source (PI-ReTOF-MS). The FTIR analysis detected six small hydrocarbon products from the three different irradiation sources: propane [C 3 H 8 (C 3 D 8 )], ethane [C 2 H 6 (C 2 D 6 )], the ethyl radical [C 2 H 5 (C 2 D 5 )], ethylene [C 2 H 4 (C 2 D 4 )], acetylene [C 2 H 2 (C 2 D 2 )], and the methyl radical [CH 3 (CD 3 )]. The sensitive PI-ReTOF-MS analysis identified a complex array of products with different products being detected between experiments with general formulae: C n H 2n+2 (n = 4-8), C n H 2n (n = 3-9), C n H 2n-2 (n = 3-9), C n H 2n-4 (n = 4-9), and C n H 2n-6 (n = 6-7) from electron irradiation and C n H 2n+2 (n = 4-8), C n H 2n (n = 3-10), C n H 2n-2 (n = 3-11), C n H 2n-4 (n = 4-11), C n H 2n-6 (n = 5-11), and C n H 2n-8 (n = 6-11) from broadband photolysis and Lyman α photolysis. These experiments show that even the simplest hydrocarbon can produce important complex hydrocarbons such as C 3 H 4 and C 4 H 6 isomers. Distinct isomers from these groups have been shown to be important reactants in the synthesis of polycyclic aromatic hydrocarbons like indene (C 9 H 8 ) and naphthalene (C 10 H 8

  1. Analysis of causes of radiation overexposures for radiation workers in industrial radiography

    Mahajan, J.M.; Massand, O.P.

    2001-01-01

    About 5500 radiation workers are monitored from industrial institutions in our country out of which 3600 radiation workers are working in industrial radiography institutions. These workers have a higher potential of receiving overexposure (equivalent dose 3 10 mSv) due to their nature of work. This paper presents analysis of overexposures and their causes for radiation workers working in industrial radiography institutions during the last seven years. (author)

  2. Upper bounds on the entropy of radiation systems

    汪定雄

    1997-01-01

    The upper bounds on the entropy of a radiation system confined to a spherical box are calculated in six cases by using the equation of state of radiation in flat spacetime and the equation of state of radiation near black-hole horizon,which was derived by Li and Liu (hereafter the Li-Liu equation).It turns out that the Li-Liu equation does have unique advantage in dealing with the entropy bound of critical self-gravitating radiation systems,while the usual equation of state will result in entropy divergence.In the case of non-self-gravitating radiation systems and non-critical self-gravitating radiation systems,there is no difference in the entropy bounds derived by these two equations of state.

  3. A local-area-network based radiation oncology microcomputer system

    Chu, W.K.; Taylor, T.K.; Kumar, P.P.; Imray, T.J.

    1985-01-01

    The application of computerized technology in the medical specialty of radiation oncology has gained wide acceptance in the past decade. Recognizing that most radiation oncology department personnel are familiar with computer operations and terminology, it appears reasonable to attempt to expand the computer's applications to other departmental activities, such as scheduling, record keeping, billing, treatment regimen and status, etc. Instead of sharing the processing capability available on the existent treatment minicomputer, the radiation oncology computer system is based upon a microcomputer local area network (LAN). The system was conceptualized in 1984 and completed in March 1985. This article outlines the LAN-based radiation oncology computer system

  4. Radiation-induced effects in organic systems. Final report

    Johnsen, R.H.

    1982-01-01

    This project, which is of twenty-seven years duration, has been devoted to furthering our basic understanding of the processes involved in the absorption and distribution of high-energy radiation in organic molecules. The early phases of the work were concerned with the gross chemical effects of radiation and included studies in a number of important classes of organic compounds including alcohols, aliphatic acids, aliphatic hydrocarbons, and aromatic hydrocarbons. Basic information was acquired through these studies that has led to a better understanding of the effects of high-energy radiation on condensed media. During this period the so-called protective effect of low concentrations of aromatic hydrocarbons was also studied. A contribution of lasting significance at this time was the development of a technique for the post-radiolysis analysis of trapped free radicals by photochemical means. A comprehensive series of papers on the reactions of thermal hydrogen atoms with frozen organic substrates represented the beginning of a new phase in the approach to the problems of radiation chemistry in this laboratory. Since that time the general philosophy guided the research has been to single out events or processes suspected of contributing to the gross-radiation effect and study them in isolation. Thus from 1970 on efforts were devoted to charge-exchange processes, ionization efficiencies (w-values), radical decay process in solids and ion-dissociation reactions. The first by means of a modified time-of-flight mass spectrometer, the second utilizing an ionization chamber constructed in the FSU shops, the third using electron spin resonance detection, and the last involving the use of a dual mass spectrometer, solid target system invented in our laboratory. The most productive of these efforts has been the radical decay work

  5. Radiation from a Slot System in the Coaxial Line Shield

    Katrich, V. A.; Lyashchenko, V. A.; Medvedev, N. V.

    2012-06-01

    The problem of electromagnetic wave excitation, scattering and radiation by the system of transverse slots, cut in the outer conductor of an infinite coaxial line, is solved by the magnetomotive forces method. The radiation and reflection coefficients of the circular and arc slot systems are investigated in dependence on slot sizes and feeder parameters. The processes of radiation into lossy material media are studied. The researches have been carried out with the interconnection between slots of internal and external regions considered.

  6. Theoretical analysis of infrared radiation shields of spacecraft

    Shealy, D. L.

    1984-01-01

    For a system of N diffuse, gray body radiation shields which view only adjacent surfaces and space, the net radiation method for enclosures has been used to formulate a system of linear, nonhomogeneous equations in terms of the temperatures to the fourth power of each surface in the coupled system of enclosures. The coefficients of the unknown temperatures in the system of equations are expressed in terms of configuration factors between adjacent surfaces and the emissivities. As an application, a system of four conical radiation shields for a spin stabilized STARPROBE spacecraft has been designed and analyzed with respect to variations of the cone half angles, the intershield spacings, and emissivities.

  7. Film analysis systems and applications

    Yonekura, Y.; Brill, A.B.

    1981-01-01

    The different components that can be used in modern film analysis systems are reviewed. TV camera and charge-coupled device sensors coupled to computers provide low cost systems for applications such as those described. The autoradiography (ARG) method provides an important tool for medical research and is especially useful for the development of new radiopharmaceutical compounds. Biodistribution information is needed for estimation of radiation dose, and for interpretation of the significance of observed patterns. The need for such precise information is heightened when one seeks to elucidate physiological principles/factors in normal and experimental models of disease. The poor spatial resolution achieved with current PET-imaging systems limits the information on radioreceptor mapping, neutrotransmitter, and neuroleptic drug distribution that can be achieved from patient studies. The artful use of ARG in carefully-controlled animal studies will be required to provide the additional information needed to fully understand results obtained with this new important research tool. (ERB)

  8. Film analysis systems and applications

    Yonekura, Y.; Brill, A.B.

    1981-01-01

    The different components that can be used in modern film analysis systems are reviewed. TV camera and charge-coupled device sensors coupled to computers provide low cost systems for applications such as those described. The autoradiography (ARG) method provides an important tool for medical research and is especially useful for the development of new radiopharmaceutical compounds. Biodistribution information is needed for estimation of radiation dose, and for interpretation of the significance of observed patterns. The need for such precise information is heightened when one seeks to elucidate physiological principles/factors in normal and experimental models of disease. The poor spatial resolution achieved with current PET-imaging systems limits the information on radioreceptor mapping, neutrotransmitter, and neuroleptic drug distribution that can be achieved from patient studies. The artful use of ARG in carefully-controlled animal studies will be required to provide the additional information needed to fully understand results obtained with this new important research tool

  9. Results of primary central nervous system lymphoma treated by radiation and chemotherapy. Retrospective analysis of twelve institutions in the Tokai district of Japan, 1995-1999

    Kawamura, Toshiki; Ishiguchi, Tsuneo; Shibamoto, Yuta

    2006-01-01

    We analyzed the therapeutic results and prognostic factors of 46 primary central nervous system lymphoma (PCNSL) patients who were treated at twelve institutions in the Tokai district of Japan between 1995 and 1999. We compared the results with those of a Japanese nationwide survey performed in the past. We sent each institution a questionnaire about the state of patients' disease, pathological type, method and doses of radiotherapy, regimen and intensity of chemotherapy, and patients' prognoses. The range of patients' ages was 33 to 93 years (median, 61 years). Thirty-one were men and 15 were women. The most prevalent histology was diffuse large B cell type (33 patients). We used the Kaplan-Meier method to calculate the survival rate and Cox's proportional hazards model to analyze the prognostic factors. The five-year cumulative survival rate was 25%, and the median survival time was 22.7 months. The five-year disease-free survival rate was 23%. In monovariate analysis, patients who were both younger than 60 years old and had a World Health Organization (WHO) performance status (PS) score equal to or less than 2 showed a better survival rate. Furthermore, the patients receiving systemic chemotherapy showed a significantly better local control rate. In addition, patients who received systemic chemotherapy achieved a higher complete remission rate than those not receiving it. However, no factors that significantly influenced survival rate were identified in multivariate analysis. We demonstrated that the therapeutic outcome of PCNSL patients has recently improved. In particular, patients with good PS showed better local control than those with poor PS. However, we could not identify any significant prognostic factors in PCNSL patients. (author)

  10. Analysis of changes in environmental radiation, and three types of environmental radiation detector performance comparisons

    Park, J.H; Seo, J.H; Park, S.M; Yu, B.N; Park, J.H; Joo, K.S

    2013-06-01

    High-pressure ion chamber (GE Reuter-Stokes, HPIC), accuracy is high but the high price and do not have the ability nuclide analysis is a disadvantage. NaI(Tl) and PMT scintillation detector of radioactive materials can be divided. Environmental radiation measurements using a semiconductor with SiPM detector PMT to replace the value of the results were compared. SiPM detector using radiation environment were measured in the field to verify the accuracy and energy resolution. SiPMs performance as environmental radiation measurement equipment and radioactive material distinction as a personal dosimeter based technology, using the above results were prepared. The interest on the environmental radiation due to the Fukushima power plant crisis in Japan has been growing concern about the radiation environment of the relatively close proximity Korea is a very heightened state. Could be confirmed in the radiation environment of nuclear power plants around the analysis and performance of the next generation of environmental radiation meter. Fukushima power plants accident after 2 years, the equipment installed by this analysis meets the performance as a radiation detector could be confirmed as follows. CANA Inc. developed by radionuclides classification of using man-made and natural radionuclides and man-made radionuclides separated, ensure the value of the results were analyzed. Could be and alternative to the conventional detector energy resolution ( 137 CS<15%) and linearity (<15%) to satisfy the performance requirements of the measurement result of environmental radiation detector is considered. SiPM radiation environment changes and HPIC and NaI(TI) scintillation detector installed in Korea of the Fukushima power plant after the accident, radiation environment using a small alternative was to verify the accuracy of the measuring equipment. A big difference in performance as invisible by comparison with the large detector Assay miniaturization rough as a personal

  11. A comprehensive centralized control system for radiation waste treatment facility

    Kong Jinsong

    2014-01-01

    A comprehensive centralized control system is designed for the radiation waste treatment facility that lacking of coordinated operational mechanism for the radiation waste treatment. The centralized control and alarm linkage of various systems is implemented to ensure effectively the safety of nuclear facility and materials, improve the integral control ability through advanced informatization ways. (author)

  12. A radiation monitoring system for nuclear power plants

    Iwai, Masaru; Nakamori, S.; Ikeda, H.; Oda, M.

    1974-01-01

    Safety with respect to radiation is vital factor, particularly in view of the increasing number of nuclear power plants. For this purpose, a radiation monitoring system is provided to perform constant supervision. This article describes the purpose, installation location, specifications and circuitry of a system which is divided into three units: the process monitor, area monitor and off-site monitor. (auth.)

  13. Study of the casting speedy radiation-detection system

    Tan Xiaochun; Huang Junqing; Shi Xianbei; Zhao Gang; Wang Liping

    2001-01-01

    The paper introduces the design of the launching speedy radiation-detection system. It consists of launcher, semiconductor detector, microprocessor and communicator. It can give the intensity, position, time of radiation. The paper discusses the function, composition, principle, speciality and technical problem of this system

  14. Terrestrial radiation effects in ULSI devices and electronic systems

    Ibe, Eishi H

    2014-01-01

    A practical guide on how mathematical approaches can be used to analyze and control radiation effects in semiconductor devices within various environments Covers faults in ULSI devices to failures in electronic systems caused by a wide variety of radiation fields, including electrons, alpha -rays, muons, gamma rays, neutrons and heavy ions. Readers will learn the environmental radiation features at the ground or avionics altitude. Readers will also learn how to make numerical models from physical insight and what kind of mathematical approaches should be implemented to analyze the radiation effects. A wide variety of mitigation techniques against soft-errors are reviewed and discussed. The author shows how to model sophisticated radiation effects in condensed matter in order to quantify and control them. The book provides the reader with the knowledge on a wide variety of radiation fields and their effects on the electronic devices and systems. It explains how electronic systems including servers and rout...

  15. Development of Computer Program for Analysis of Irregular Non Homogenous Radiation Shielding

    Bang Rozali; Nina Kusumah; Hendro Tjahjono; Darlis

    2003-01-01

    A computer program for radiation shielding analysis has been developed to obtain radiation attenuation calculation in non-homogenous radiation shielding and irregular geometry. By determining radiation source strength, geometrical shape of radiation source, location, dimension and geometrical shape of radiation shielding, radiation level of a point at certain position from radiation source can be calculated. By using a computer program, calculation result of radiation distribution analysis can be obtained for some analytical points simultaneously. (author)

  16. Cost benefit analysis for occupational radiation exposure

    Caruthers, G.F.; Rodgers, R.C.; Donohue, J.P.; Swartz, H.M.

    1978-01-01

    In the course of system design, many decisions must be made concerning different aspects of that particular system. The design of systems and components in a nuclear power plant has the added faction of occupational exposure experienced as a result of that design. This paper will deal with the different methods available to factor occupational exposure into design decisions. The ultimate goal is to have exposures related to the design 'As Low As Reasonably Achievable' or ALARA. To do this an analysis should be performed to show that the cost of reducing exposures any further cannot be justified in a cost-benefit analysis. In this paper examples will be given that will show that it is possible to change to a design which would increase occupational exposure somewhat but would increase the benefit over the cost of the extra exposure received. It will also be shown that some changes in design or additional equipment could be justified due to a reduction in exposure while some changes could not be justified on a reduction in exposure aspect alone but are justified on a time saving aspect such as during a refueling outage. (author)

  17. Discussion on several problems in evolution of radiation protection system

    Ziqiang, P.

    2004-01-01

    As viewed from the standpoint of radiation protection practice, it is necessary that the current system of radiological protection should be made more simple and coherent. The human-based protective measures alone are far from having met the requirements of environmental protection in many circumstances. Protecting the environment from ionising radiation would be implicated in radiation protection. Collective dose is an useful indicator, of which applicable extent should be defined. Using such an quantity could help improve radiation protection level, but applicable conditions should be indicated, temporal or spatial. Natural radiation is the largest contributor to the radiation exposure of human. Occupational exposure from natural radiation should be controlled, for occupations such as underground miners and air crew. Controlling both man-made and natural radiation exposure of pregnant women and children needs to be enhanced, especially radiological diagnosis and treatment. China radiation protection community, as a whole, is paying considerable attention to the ICRP's new Recommendations. Prof. Clarke's article 'A Report on Progress towards New Recommendations', a communication from the International Commission on Radiological Protection, has been translated into Chinese and published on Radiation Protection, the Official Journal of China Radiation Protection Society with a view of intensifying awareness of the new Recommendations within more radiation protection workers and people concerned. In addition, a special meeting was convened in early 2002 to address the comments on the new Recommendations. (author)

  18. The software design of area γ radiation monitoring system

    Song Chenxin; Deng Changming; Cheng Chang; Ren Yi; Meng Dan; Liu Yun

    2007-01-01

    This paper main introduction the system structure, software architecture, design ideas of the area γ radiation monitoring system. Detailed introduction some programming technology about the computer communication with the local display unit. (authors)

  19. The software design of area γ radiation monitoring system

    Song Chenxin; Deng Changming; Cheng Chang; Ren Yi; Meng Dan; Liu Yun

    2008-01-01

    This paper main introduction the system structure, software architecture, design ideas of the area γ radiation monitoring system. Detailed introduction some programming technology about the computer communication with the local display unit. (authors)

  20. PWR systems transient analysis

    Kennedy, M.F.; Peeler, G.B.; Abramson, P.B.

    1985-01-01

    Analysis of transients in pressurized water reactor (PWR) systems involves the assessment of the response of the total plant, including primary and secondary coolant systems, steam piping and turbine (possibly including the complete feedwater train), and various control and safety systems. Transient analysis is performed as part of the plant safety analysis to insure the adequacy of the reactor design and operating procedures and to verify the applicable plant emergency guidelines. Event sequences which must be examined are developed by considering possible failures or maloperations of plant components. These vary in severity (and calculational difficulty) from a series of normal operational transients, such as minor load changes, reactor trips, valve and pump malfunctions, up to the double-ended guillotine rupture of a primary reactor coolant system pipe known as a Large Break Loss of Coolant Accident (LBLOCA). The focus of this paper is the analysis of all those transients and accidents except loss of coolant accidents

  1. Multidisciplinary System Reliability Analysis

    Mahadevan, Sankaran; Han, Song; Chamis, Christos C. (Technical Monitor)

    2001-01-01

    The objective of this study is to develop a new methodology for estimating the reliability of engineering systems that encompass multiple disciplines. The methodology is formulated in the context of the NESSUS probabilistic structural analysis code, developed under the leadership of NASA Glenn Research Center. The NESSUS code has been successfully applied to the reliability estimation of a variety of structural engineering systems. This study examines whether the features of NESSUS could be used to investigate the reliability of systems in other disciplines such as heat transfer, fluid mechanics, electrical circuits etc., without considerable programming effort specific to each discipline. In this study, the mechanical equivalence between system behavior models in different disciplines are investigated to achieve this objective. A new methodology is presented for the analysis of heat transfer, fluid flow, and electrical circuit problems using the structural analysis routines within NESSUS, by utilizing the equivalence between the computational quantities in different disciplines. This technique is integrated with the fast probability integration and system reliability techniques within the NESSUS code, to successfully compute the system reliability of multidisciplinary systems. Traditional as well as progressive failure analysis methods for system reliability estimation are demonstrated, through a numerical example of a heat exchanger system involving failure modes in structural, heat transfer and fluid flow disciplines.

  2. Radiation detector system having heat pipe based cooling

    Iwanczyk, Jan S.; Saveliev, Valeri D.; Barkan, Shaul

    2006-10-31

    A radiation detector system having a heat pipe based cooling. The radiation detector system includes a radiation detector thermally coupled to a thermo electric cooler (TEC). The TEC cools down the radiation detector, whereby heat is generated by the TEC. A heat removal device dissipates the heat generated by the TEC to surrounding environment. A heat pipe has a first end thermally coupled to the TEC to receive the heat generated by the TEC, and a second end thermally coupled to the heat removal device. The heat pipe transfers the heat generated by the TEC from the first end to the second end to be removed by the heat removal device.

  3. Radiation Safety System for SPIDER Neutral Beam Accelerator

    Sandri, S.; Poggi, C.; Coniglio, A.; D'Arienzo, M.

    2011-01-01

    SPIDER (Source for Production of Ion of Deuterium Extracted from RF Plasma only) and MITICA (Megavolt ITER Injector Concept Advanced) are the ITER neutral beam injector (NBI) testing facilities of the PRIMA (Padova Research Injector Megavolt Accelerated) Center. Both injectors accelerate negative deuterium ions with a maximum energy of 1 MeV for MITICA and 100 keV for SPIDER with a maximum beam current of 40 A for both experiments. The SPIDER facility is classified in Italy as a particle accelerator. At present, the design of the radiation safety system for the facility has been completed and the relevant reports have been presented to the Italian regulatory authorities. Before SPIDER can operate, approval must be obtained from the Italian Regulatory Authority Board (IRAB) following a detailed licensing process. In the present work, the main project information and criteria for the SPIDER injector source are reported together with the analysis of hypothetical accidental situations and safety issues considerations. Neutron and photon nuclear analysis is presented, along with special shielding solutions designed to meet Italian regulatory dose limits. The contribution of activated corrosion products (ACP) to external exposure of workers has also been assessed. Nuclear analysis indicates that the photon contribution to worker external exposure is negligible, and the neutron dose can be considered by far the main radiation protection issue. Our results confirm that the injector has no important radiological impact on the population living around the facility.

  4. Validation of MCNP4A for repository scattered radiation analysis

    Haas, M.N.; Su, S.

    1998-02-01

    Comparison is made between experimentally determined albedo (scattered) radiation and MCNP4A predictions in order to provide independent validation for repository shielding analysis. Both neutron and gamma scattered radiation fields from concrete ducts are compared in this paper. Satisfactory agreement is found between actual and calculated results with conservative values calculated by the MCNP4A code for all conditions

  5. The 3D Radiation Dose Analysis For Satellite

    Cai, Zhenbo; Lin, Guocheng; Chen, Guozhen; Liu, Xia

    2002-01-01

    the earth. These particles come from the Van Allen Belt, Solar Cosmic Ray and Galaxy Cosmic Ray. They have different energy and flux, varying with time and space, and correlating with solar activity tightly. These particles interact with electrical components and materials used on satellites, producing various space radiation effects, which will damage satellite to some extent, or even affect its safety. orbit. Space energy particles inject into components and materials used on satellites, and generate radiation dose by depositing partial or entire energy in them through ionization, which causes their characteristic degradation or even failure. As a consequence, the analysis and protection for radiation dose has been paid more attention during satellite design and manufacture. Designers of satellites need to analyze accurately the space radiation dose while satellites are on orbit, and use the results as the basis for radiation protection designs and ground experiments for satellites. can be calculated, using the model of the trapped proton and the trapped electron in the Van Allen Belt (AE8 and AP8). This is the 1D radiation dose analysis for satellites. Obviously, the mass shielding from the outside space to the computed point in all directions is regarded as a simple sphere shell. The actual structure of satellites, however, is very complex. When energy particles are injecting into a given equipment inside satellite from outside space, they will travel across satellite structure, other equipment, the shell of the given equipment, and so on, which depends greatly on actual layout of satellite. This complex radiation shielding has two characteristics. One is that the shielding masses for the computed point are different in different injecting directions. The other is that for different computed points, the shielding conditions vary in all space directions. Therefore, it is very difficult to tell the differences described above using the 1D radiation analysis, and

  6. Radiative transfer in atmosphere-sea ice-ocean system

    Jin, Z.; Stamnes, K.; Weeks, W.F. [Univ. of Alaska, Fairbanks, AK (United States); Tsay, S.C. [NASA Goddard Space Flight Center, Greenbelt, MD (United States)

    1996-04-01

    Radiative energy is critical in controlling the heat and mass balance of sea ice, which significantly affects the polar climate. In the polar oceans, light transmission through the atmosphere and sea ice is essential to the growth of plankton and algae and, consequently, to the microbial community both in the ice and in the ocean. Therefore, the study of radiative transfer in the polar atmosphere, sea ice, and ocean system is of particular importance. Lacking a properly coupled radiative transfer model for the atmosphere-sea ice-ocean system, a consistent study of the radiative transfer in the polar atmosphere, snow, sea ice, and ocean system has not been undertaken before. The radiative transfer processes in the atmosphere and in the ice and ocean have been treated separately. Because the radiation processes in the atmosphere, sea ice, and ocean depend on each other, this separate treatment is inconsistent. To study the radiative interaction between the atmosphere, clouds, snow, sea ice, and ocean, a radiative transfer model with consistent treatment of radiation in the coupled system is needed and is under development.

  7. Analysis of dicentrics in human lymphocytes exposed to ionizing radiation using the automated system and optical microscope; Analisis de dicentricos en linfocitos humanos expuestos a radiacion ionizante mediante el sistema automatizado y microscopio optico

    Martinez A, J.

    2016-07-01

    Ionizing radiation is a form of energy that produces ionizations in the molecules it traverses. When the higher energy radiation interacts with the structure of human chromosomes, chromosome aberrations, mainly of the dicentric type, are the union of two damaged chromosomes, represented by two centromeres and non centromere fragment. There are situations where a population of people may be affected by the release of any radioactive material and it is impossible to determine in a short time the absorbed dose to which each person was exposed. The dicentrics analysis from the culture of human lymphocytes is used to estimate doses of exposure to ionizing radiation, using the optical microscope. The objective of this work is to analyze dicentric chromosomal lesions, using the optical microscope in comparison with the semi-automated system, to respond promptly to radiological emergencies. For this study, two samples irradiated with {sup 60}Co were analyzed, one in the Instituto Nacional de Investigaciones Nucleares (ININ) reaching doses of 2.7 ± 0.1 and 0.85 ± 0.1 Gy, and the other in Walischmiller Engineering G mb H, Markdorf (Germany) reaching doses of 0.84 ± 0.3 and 2.8 ± 0.1 Gy. A lymphocyte culture was performed following the recommendations of the IAEA, using minimum essential MEM medium previously prepared with BrdU, sodium heparin, antibiotic and L-glutamine. Phytohemagglutinin, fetal calf serum was added to the sample, incubated at 37 degrees Celsius for 48 hours and three hours before the end of incubation, colcemide was placed. KCl post-culture was added and lamellae were prepared by washing with the 3:1 acid-acetic fixative solution and a Giemsa staining. 1000 cell readings were performed using the optical microscope and the automated system according to study protocols and quality standards to estimate absorbed dose by means of dicentric analysis, defined by ISO-19238. With the automated system similar results of absorbed dose were obtained with respect

  8. Phase analysis and focusing of synchrotron radiation

    Chubar, O; Snigirev, A

    1999-01-01

    High accuracy calculations of synchrotron radiation (SR) emitted by a relativistic electron show that the phase of the frequency domain electric field of SR differs from the phase of radiation of a virtual point source. These differences may result in the reduction of focusing efficiency of diffraction-limited SR, if the focusing is performed by conventional optical components optimised for point sources. We show that by applying a phase correction locally, one may transform the phase of SR electric field at a desired polarisation to that of a point source. Such corrections are computed for undulator radiation (planar and helical) and bending magnet radiation (central part and edges). The focusing of the corrected SR wavefront can result in the increase of peak intensity in the focused spot up to several times compared to the focusing without correction. For non-diffraction-limited radiation, the effect of the phase corrections is reduced. Due to this reason, the use of the proposed phase corrections in exist...

  9. Radiator selection for Space Station Solar Dynamic Power Systems

    Fleming, Mike; Hoehn, Frank

    A study was conducted to define the best radiator for heat rejection of the Space Station Solar Dynamic Power System. Included in the study were radiators for both the Organic Rankine Cycle and Closed Brayton Cycle heat engines. A number of potential approaches were considered for the Organic Rankine Cycle and a constructable radiator was chosen. Detailed optimizations of this concept were conducted resulting in a baseline for inclusion into the ORC Preliminary Design. A number of approaches were also considered for the CBC radiator. For this application a deployed pumped liquid radiator was selected which was also refined resulting in a baseline for the CBC preliminary design. This paper reports the results and methodology of these studies and describes the preliminary designs of the Space Station Solar Dynamic Power System radiators for both of the candidate heat engine cycles.

  10. Method and circuit for stabilizing conversion gain of radiation detectors of a radiation detection system

    Stoub, E.W.

    1986-01-01

    A method is described for calibrating the gain of an array of radiation detectors of a radiation detection system comprising the steps of: (a) measuring in parallel for each radiation detector using a predetermined calibration point the energy map status, thereby obtaining an energy response vector whose elements correspond to the individual output of each radiation detector, each predetermined calibration point being a prescribed location corresponding to one of the radiation detectors; (b) multiplying that energy response vector with a predetermined deconvolution matrix, the deconvolution matrix being the inversion of a contribution matrix containing matrix elements C/sub IJ/, each such matrix element C/sub IJ/ of the contribution matrix representing the relative contribution level of a radiation detector j of the detection system for a point radiation source placed at a location i, thereby obtaining a gain vector product for the radiation detectors; (c) adjusting the gains of the radiation detectors with respect to the gain vector product such that a unity gain vector is essentially obtained; (d) measuring again the energy map status according to step (a); and (e) if the energy map status fails to essentially produce a unity gain vector repeat steps (a) to (d) until the energy map status substantially corresponds to unity

  11. Timing of Chemotherapy After MammoSite Radiation Therapy System Breast Brachytherapy: Analysis of the American Society of Breast Surgeons MammoSite Breast Brachytherapy Registry Trial

    Haffty, Bruce G.; Vicini, Frank A.; Beitsch, Peter; Quiet, Coral; Keleher, Angela; Garcia, Delia; Snider, Howard; Gittleman, Mark; Zannis, Victor; Kuerer, Henry; Whitacre, Eric; Whitworth, Pat; Fine, Richard; Keisch, Martin

    2008-01-01

    Purpose: To evaluate cosmetic outcome and radiation recall in the American Society of Breast Surgeons registry trial, as a function of the interval between accelerated partial breast irradiation (APBI) and initiation of chemotherapy (CTX). Methods and Materials: A total of 1440 patients at 97 institutions participated in this trial. After lumpectomy for early-stage breast cancer, patients received APBI (34 Gy in 10 fractions) with MammoSite RTS brachytherapy. A total of 148 patients received CTX within 90 days of APBI. Cosmetic outcome was evaluated at each follow-up visit and dichotomized as excellent/good or fair/poor. Results: Chemotherapy was initiated at a mean of 3.9 weeks after the final MammoSite procedure and was administered ≤3 weeks after APBI in 54 patients (36%) and >3 weeks after APBI in 94 patients (64%). The early and delayed groups were well balanced with respect to multiple factors that may impact on cosmetic outcome. There was a superior cosmetic outcome in those receiving chemotherapy >3 weeks after APBI (excellent/good in 72.2% at ≤3 weeks vs. excellent/good in 93.8% at >3 weeks; p = 0.01). Radiation recall in those receiving CTX at ≤3 weeks was 9 of 50 (18%), compared with 6 of 81(7.4%) in those receiving chemotherapy at >3 weeks (p = 0.09). Conclusion: The majority of patients receiving CTX after APBI have excellent/good cosmetic outcomes, with a low rate of radiation recall. Chemotherapy initiated >3 weeks after the final MammoSite procedure seems to be associated with a better cosmetic outcome and lower rate of radiation recall. An excellent/good cosmetic outcome in patients receiving CTX after 3 weeks was similar to the cosmetic outcome of the overall patient population who did not receive CTX

  12. Measurement tolerance analysis of solar radiation

    Cimo, J.; Maderkova, L.; Horak, J.; Igaz, D.; Pasztorova, S. [Department of Biomereorlogy and Hydrology, Slovak Agriculture University, Nitra (Slovakia)

    2012-07-01

    Solar radiant energy is bane and almost the only one source of heat for Earth 's surface and for atmosphere, and almost the only one source of energy for physical processes. Solar energy is one of the most available and the most ecological energy source. Currently the firm Kipp and Zonen belongs to prominent producer of sensors for measuring of global radiation. These sensors are the most used in our country and also in network of meteorological measurements of WMO. Therefore the two types of measuring sensors for global radiation (pyranometer PMP6, CMP 11) in comparison with calculation method Savin-Angstrom are analysed. (author)

  13. Analysis of errors of radiation relay, (1)

    Koyanagi, Takami; Nakajima, Sinichi

    1976-01-01

    The statistical error of liquid level controlled by radiation relay is analysed and a method of minimizing the error is proposed. This method comes to the problem of optimum setting of the time constant of radiation relay. The equations for obtaining the value of time constant are presented and the numerical results are shown in a table and plotted in a figure. The optimum time constant of the upper level control relay is entirely different from that of the lower level control relay. (auth.)

  14. CFD analysis of heat transfer performance of graphene based hybrid nanofluid in radiators

    Bharadwaj, Bharath R.; Sanketh Mogeraya, K.; Manjunath, D. M.; Rao Ponangi, Babu; Rajendra Prasad, K. S.; Krishna, V.

    2018-04-01

    For Improved performance of an automobile engine, Cooling systems are one of the critical systems that need attention. With increased capacity to carry away large amounts of wasted heat, performance of an engine is increased. Current research on Nano-fluids suggests that they offer higher heat transfer rate compared to that of conventional coolants. Hence this project seeks to investigate the use of hybrid-nanofluids in radiators so as to increase its heat transfer performance. Carboxyl Graphene and Graphene Oxide based nanoparticles were selected due to the very high thermal conductivity of Graphene. System Analysis of the radiator was performed by considering a small part of the whole automobile radiator modelled using SEIMENS NX. CFD analysis was conducted using ANSYS FLUENT® for the nanofluid defined and the increase in effectiveness was compared to that of conventional coolants. Usage of such nanofluids for a fixed cooling requirement in the future can lead to significant downsizing of the radiator.

  15. Analysis by absorption and scattering of radiation. A current bibliography

    Bujdoso, E.

    2002-01-01

    A current bibliography with 100 references based on INIS Atomindex has been compiled on Analysis by absorption and scattering of radiation for years 1998-1999. References are arranged by first author's names. (N.T.)

  16. Human · mouse genome analysis and radiation biology. Proceedings

    Hori, Tada-aki

    1994-03-01

    This issue is the collection of the papers presented at the 25th NIRS symposium on Human, Mouse Genome Analysis and Radiation Biology. The 14 of the presented papers are indexed individually. (J.P.N.)

  17. Report on the Radiation Effects Testing of the Infrared and Optical Transition Radiation Camera Systems

    Holloway, Michael Andrew [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-04-20

    Presented in this report are the results tests performed at Argonne National Lab in collaboration with Los Alamos National Lab to assess the reliability of the critical 99Mo production facility beam monitoring diagnostics. The main components of the beam monitoring systems are two cameras that will be exposed to radiation during accelerator operation. The purpose of this test is to assess the reliability of the cameras and related optical components when exposed to operational radiation levels. Both X-ray and neutron radiation could potentially damage camera electronics as well as the optical components such as lenses and windows. This report covers results of the testing of component reliability when exposed to X-ray radiation. With the information from this study we provide recommendations for implementing protective measures for the camera systems in order to minimize the occurrence of radiation-induced failure within a ten month production run cycle.

  18. Evolution of Radiation Protection System in Kenya

    Maina, J. A. W.

    2004-01-01

    Promulgation of radiation protection legislation in Kenya dates back to 1982, was revised in 1985 and became operational in 1986. This law, the Radiation Protection Act, establishes the Radiation Protection Board as the National Regulatory Authority, with an executive Inspectorate headed by the Secretary to the Board. Subsidiary legislation on radiological practices and standards were subsequently published. The Inspectorate carries out the National programme for notification, authorization, inspection and enforcement. Nuclear applications for peaceful purposes in Kenya are on the increase in all major fields of socio-economic development. Provision of regulatory services, guidance and enforcement procedures, has had a net growth over the last fifteen years. However, staff retention has been declining over the years in a market where job opportunities, with relatively high incentives, are high either inside or outside the country. Human and equipment resource development has therefore not kept pace and this has hampered effective and efficient provision of services. The poor status of the economy has had its impact on delivery of quality, effective and efficient radiation protection services. Provision of radiation services and acquisition of radiation detection and measurement equipment in the country has been generally lacking dating as far back as 1995. During the period 1989 to present, Kenya's Regulatory Authority, the Radiation Protection Board, undertook to provide personal monitoring, quality assurance, radioanalysis, and equipment calibration. Over the years these services have stalled due to outdated equipment most of which have broken down. A maintenance and calibration service for nuclear equipment is an expensive cross-boarder issue. Budgetary constraints, insufficient human and equipment resources, and a perennial 'brain drain' has placed limitations to the effectiveness and efficiency of implementation of the National programmes and slowed the

  19. The development of remote wireless radiation dose monitoring system

    Lee, Jin-woo; Jeong, Kyu-hwan; Kim, Jong-il; Im, Chae-wan

    2015-01-01

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

  20. The development of remote wireless radiation dose monitoring system

    Lee, Jin-woo [KAERI - Korea Atomic Energy Research Institute, Jeongup-si (Korea, Republic of); Chonbuk National University, Jeonjoo-Si (Korea, Republic of); Jeong, Kyu-hwan [KINS - Korea Institute of Nuclear Safety, Daejeon-Si (Korea, Republic of); Kim, Jong-il [Chonbuk National University, Jeonjoo-Si (Korea, Republic of); Im, Chae-wan [REMTECH, Seoul-Si (Korea, Republic of)

    2015-07-01

    Internet of things (IoT) technology has recently shown a large flow of IT trends in human life. In particular, our lives are now becoming integrated with a lot of items around the 'smart-phone' with IoT, including Bluetooth, Near Field Communication (NFC), Beacons, WiFi, and Global Positioning System (GPS). Our project focuses on the interconnection of radiation dosimetry and IoT technology. The radiation workers at a nuclear facility should hold personal dosimeters such as a Thermo-Luminescence Dosimeter (TLD), an Optically Stimulated Luminescence Dosimeter (OSL), pocket ionization chamber dosimeters, an Electronic Personal Dosimeter (EPD), or an alarm dosimeter on their body. Some of them have functions that generate audible or visible alarms to radiation workers in a real working area. However, such devices used in radiation fields these days have no functions for communicating with other areas or the responsible personnel in real time. In particular, when conducting a particular task in a high dose area, or a number of repair works within a radiation field, radiation dose monitoring is important for the health of the workers and the work efficiency. Our project aims at the development of a remote wireless radiation dose monitoring system (RWRD) that can be used to monitor the radiation dose in a nuclear facility for radiation workers and a radiation protection program In this project, a radiation dosimeter is the detection device for personal radiation dose, a smart phone is the mobile wireless communication tool, and, Beacon is the wireless starter for the detection, communication, and position of the worker using BLE (Bluetooth Low Energy). In this report, we report the design of the RWRD and a demonstration case in a real radiation field. (authors)

  1. Cooling Characteristic Analysis of Transformer's Radiator

    Kim, Hyun Jae; Yang, Si Won; Kim, Won Seok; Kweon, Ki Yeoung; Lee, Min Jea

    2007-01-01

    A transformer is a device that changes the current and voltage by electricity induced between coil and core steel, and it is composed of metals and insulating materials. In the core of the transformer, the thermal load is generated by electric loss and the high temperature can make the break of insulating. So we must cool down the temperature of transformer by external radiators. According to cooling fan's usage, there are two cooling types, OA(Oil Natural Air Natural) and FA(Oil Natural Air Forced). For this study , we used Fluent 6.2 and analyzed the cooling characteristic of radiator. we calculated 1-fin of detail modeling that is similar to honeycomb structure and multi-fin(18-fin) calculation for OA and FA types. For the sensitivity study, we have different positions(side, under) of cooling fans for forced convection of FA type. The calculation results were compared with the measurement data which obtained from 135.45/69kV ultra transformer flowrate and temperature test. The aim of the study is to assess the Fluent code prediction on the radiator calculation and to use the data for optimizing transformer radiator design

  2. Development of lightweight radiators for lunar based power systems

    Juhasz, A.J.; Bloomfield, H.S.

    1994-05-01

    This report discusses application of a new lightweight carbon-carbon (C-C) space radiator technology developed under the NASA Civil-Space Technology Initiative (CSTI) High Capacity Power Program to a 20 kWe lunar based power system. This system comprises a nuclear (SP-100 derivative) heat source, a Closed Brayton Cycle (CBC) power conversion unit with heat rejection by means of a plane radiator. The new radiator concept is based on a C-C composite heat pipe with integrally woven fins and a thin walled metallic liner for containment of the working fluid. Using measured areal specific mass values (1.5 kg/m2) for flat plate radiators, comparative CBC power system mass and performance calculations show significant advantages if conventional heat pipes for space radiators are replaced by the new C-C heat pipe technology

  3. Web design and development for centralize area radiation monitoring system in Malaysian Nuclear Agency

    Ibrahim, Maslina Mohd; Yussup, Nolida; Haris, Mohd Fauzi; Soh @ Shaari, Syirrazie Che; Azman, Azraf; Razalim, Faizal Azrin B. Abdul; Yapp, Raymond; Hasim, Harzawardi; Aslan, Mohd Dzul Aiman

    2017-01-01

    One of the applications for radiation detector is area monitoring which is crucial for safety especially at a place where radiation source is involved. An environmental radiation monitoring system is a professional system that combines flexibility and ease of use for data collection and monitoring. Nowadays, with the growth of technology, devices and equipment can be connected to the network and Internet to enable online data acquisition. This technology enables data from the area monitoring devices to be transmitted to any place and location directly and faster. In Nuclear Malaysia, area radiation monitor devices are located at several selective locations such as laboratories and radiation facility. This system utilizes an Ethernet as a communication media for data acquisition of the area radiation levels from radiation detectors and stores the data at a server for recording and analysis. This paper discusses on the design and development of website that enable all user in Nuclear Malaysia to access and monitor the radiation level for each radiation detectors at real time online. The web design also included a query feature for history data from various locations online. The communication between the server's software and web server is discussed in detail in this paper.

  4. Power System Analysis

    Taniguchi, Haruhito

    Electric power generation that relies on various sources as the primary sources of energy is expected to bring down CO2 emissions levels to support the overall strategy to curb global warming. Accordingly, utilities are moving towards integrating more renewable sources for generation, mostly dispersed, and adopting Smart Grid Technologies for system control. In order to construct, operate, and maintain power systems stably and economically in such background, thorough understanding about the characteristics of power systems and their components is essential. This paper presents modeling and simulation techniques available for the analysis of critical aspects such as thermal capacity, stability, voltage stability, and frequency dynamics, vital for the stable operation of power systems.

  5. Radiation scanning system for data recording media

    Gucza, E.

    1975-01-01

    The scanner of an encoded record support operates by the reflection principle. The record support has tracks brocken down into individual fields which are assigned light-dark markers for encoding purposes.The support consists of a light, non-transparent card which can be pulled over a slot by a guide attached to the scanner. The slot is arranged at an oblique angle relative to the card and emits radiation, for instance, light. This radiation is reflected by the tracks, the empty fields reflecting more radiation than the blackend ones, and then after having been transformed into signals, impinges upon phototransistors through openings. The number of openings corresponds to the number of tracks. The light can be made diffuse prior to exposure of the card by means of a red transparent plastic foil. (DG/RF) [de

  6. Low-level radiation waste management system

    Kubofcik, K.W.

    1990-01-01

    This patent describes a low-level radiation waste container set for use in conjunction with an open-topped receptacle. It comprises: a receptacle liner having a closed end and an open end, the receptacle liner sized for deployment as an inserted liner in an open-topped receptacle for collecting low-level radiation waste material within the receptacle liner within the open-topped receptacle; a cover sized and shaped to fit over the open top of the open-topped receptacle and the receptacle liner therein with the cover is in a closed position. The cover having a depending skirt which, when the cover is in the closed position, extends downwardly to overlap the open-topped receptacle adjacent the open top thereof and a portion of the receptacle liner received therein; and the receptacle liner and cover being fabricated of flexible radiation shielding material

  7. The problem of creation of radiation monitoring system

    Pilipchak, S.I.

    1990-01-01

    The review of problem of radiation monitoring system (RMS) in the territory of the country is presented. Unsolved problems are discussed which are divided into three groups: the organization of structures in RMS; implementation of automated RMS; the solution of scientific problems of global monitoring of radiation situation. 12 refs.; 1 tab

  8. Distributing radiation management system of nuclear power plants

    Mihoya, Eiichi; Akashi, Michio

    1999-01-01

    The importance of radiation management for nuclear facilities including nuclear power plants has increased as the general public understanding has progressed, and necessary information for management must be processed exactly and quickly. In nuclear power plants, radiation management is performed by each individual operation, and collected information is managed by the system of each operation. The distributing radiation management system has been developed aiming to use a general-purpose LAN and make quick and efficient use of information managed by individual operations. This paper describes the system configuration and functions. (author)

  9. Discussion on radiation protection system from ethical issues

    Li, Xutong; Guo, Qiuju

    2002-01-01

    This paper discussed the relationship between radiation protection system and ethical principle, viz. equity and efficiency. According to the authors' opinions, the main problem that the system of radiation protection facing now is the dose-limitation principle cannot incarnate the equity principle completely. Even though the distinguishing between practice and intervention is no other than solving the problem, but the scheme is not perfect still. Ethical issues should be given more attention and be more researched when we try to modify the radiation protection system today

  10. Measurement and control systems using nuclear radiation

    Melo, Jose Altino Tupinamba; Madi Filho, Tufic

    2007-01-01

    Non-destructive Assay is applied to machines and components quality tests. These elements would not have a good performance if they were conceived without concern about the mechanical project quality, used materials, manufacture processes and inspection and maintenance methodology. In this work, a measure and control system of non destructive processes was developed, using a radioactive source with a defined energy in function of the material to be analyzed. This system involves: interface of input/output (I/O) (hardware) and graphical interface (software). In the non destructive analysis, it is made the comparison of the signal proceeding from the sensor with a signal preset (set point) or analogical signal of reference (Base Line), which is adjusted in the I/O interface. Analyzed the signal, the system will make the decision: to reject or to accept the analyzed material. The I/O interface is implemented by electronic equipment with a MCS51. The purpose of this interface is to supply conditions to exchange information, using serial RS232, between the sensor and the microcomputer. The graphical interface (software) is written in visual C++ language. (author)

  11. Radiation protection of vitamins in aqueous systems

    Kishore, K.; Moorthy, P.N.; Rao, K.N.

    1976-01-01

    A study of the radiation induced decomposition of the B-group vitamins has been carried out in aqueous media at room temperature as well as in rigid matrices at low temperature. The detailed results on the effect of glucose and oxygen as protective additives at the different temperatures are presented in the case of Thiamine (Vitamin B 1 ). Comparative data are given on the extent of decomposition of this and other vitamins of the B-group at room temperature and at 193 K. The importance of these results in connection with the radiation sterilization of pharmaceutical preparations is indicated. (author)

  12. Prototype demonstration of radiation therapy planning code system

    Little, R.C.; Adams, K.J.; Estes, G.P.; Hughes, L.S. III; Waters, L.S.

    1996-01-01

    This is the final report of a one-year, Laboratory-Directed Research and Development project at the Los Alamos National Laboratory (LANL). Radiation therapy planning is the process by which a radiation oncologist plans a treatment protocol for a patient preparing to undergo radiation therapy. The objective is to develop a protocol that delivers sufficient radiation dose to the entire tumor volume, while minimizing dose to healthy tissue. Radiation therapy planning, as currently practiced in the field, suffers from inaccuracies made in modeling patient anatomy and radiation transport. This project investigated the ability to automatically model patient-specific, three-dimensional (3-D) geometries in advanced Los Alamos radiation transport codes (such as MCNP), and to efficiently generate accurate radiation dose profiles in these geometries via sophisticated physics modeling. Modem scientific visualization techniques were utilized. The long-term goal is that such a system could be used by a non-expert in a distributed computing environment to help plan the treatment protocol for any candidate radiation source. The improved accuracy offered by such a system promises increased efficacy and reduced costs for this important aspect of health care

  13. Radiation monitoring of nuclear census intelligent data management and mobile monitoring data acquisition system

    Huang Libin; Zhong Zhijing; Zhou Yinhang; Guo Hongbo

    2014-01-01

    The system, employing advanced intelligent terminal, mobile applications, database technology, can achieve all kinds of field monitoring, mobile radiation monitoring data collected for laboratory analysis; employing GPS technology, can achieve the geographic information of the radiation monitoring data, time tagging and other anti-cheating measures; the system also established a mass database management system; the system is suitable for all types of nuclear-related units with special adaptive functions; system will be extended to GIS-based management capabilities of nuclear contamination distribution in latter stage. (authors)

  14. A utility perspective on radiation worker access control systems

    Watson, B.A.; Goff, T.E.

    1984-01-01

    Based on an evaluation of the current commercial Radiation Worker Access Control Software Systems, Baltimore Gas and Electric Company has elected to design and develop a site specific access control and accountability system for the Calvert Cliffs Nuclear Power Plant. The vendor provided systems allow for radiation worker access control based on training and external exposure records and authorizations. These systems do not afford internal exposure control until after bioassay measurements or maximum permissible concentration-hours are tabulated. The vendor provided systems allow for data trending for ALARA purposes, but each software package must be modified to meet site specific requirements. Unlike the commercial systems, the Calvert Cliffs Radiological Controls and Accountability System (RCAS) will provide radiation worker exposure control, both internal and external. The RCAS is designed to fulfill the requirements by integrating the existing Radiation Safety, Dosemetry, and Training data bases with a comprehensive radiological surveillance program. Prior to each worker's entry into the Radiological Control Area; his training and qualifications, radiation exposure history and authorization, will be compared with administrative controls, such as radiation work permits, and respiratory protection requirements and the radiological conditions in the work area. The RCAS, a computer based applied health physics access control system is described as it is presently configured for development. The mechanisms for enhancing worker internal and external exposure controls are discussed. Proposed data application to both the Calvert Cliffs ALARA and outage planning programs is included

  15. Effect of ionizing radiation on cardiovascular system

    Milliat, F.; Benderitter, M.; Gaugler, M.H.

    2011-01-01

    Radiotherapy treatment for cancer of the chest, mediastinal area or the neck area is associated with increased risk of cardiovascular disease. With the increasing number of cancer patients and the increased treatment efficiency, the number of cancer survivors is increasing exponentially. The cancer survivors live longer and their long-term follow-up must be considered. The cardiovascular toxicity is mainly associated with the treatment of breast cancer, Hodgkin's lymphoma and head and neck cancer. Radiation-induced cardiovascular effects are insidious and chronic. Their occurrence is linked to numerous factors including the age of the patient at the beginning of the radiotherapy schedule, the number of years following radiotherapy, the doses (and volume) to the heart and the large vessels (coronary and carotid arteries), and the association with the traditional cardiovascular risk factors. Pathophysiological mechanisms remain unclear and, even if similarities with age-related atherosclerosis were established, the specificities of the radiation-induced atherosclerosis for high doses remain to be discovered. For low/moderate doses of ionising radiation, recent epidemiological studies provide evidence of increased risk of cardiovascular pathologies. A better knowledge of the mechanisms associated with the radiation-induced cardiovascular pathologies and the more precise identification of the populations at risk in the future should allow a more effective care of these patients with cardiovascular risk. (authors)

  16. Structural analysis with high brilliance synchrotron radiation

    Ohno, Hideo [Japan Atomic Energy Research Inst., Kamigori, Hyogo (Japan). Kansai Research Establishment

    1997-11-01

    The research subjects in diffraction and scattering of materials with high brilliance synchrotron radiation such as SPring-8 (Super Photon ring 8 GeV) are summarized. The SPring-8 project is going well and 10 public beamlines will be opened for all users in October, 1997. Three JAERI beamlines are also under construction for researches of heavy element science, physical and structural properties under extreme conditions such as high temperature and high pressure. (author)

  17. Transistor Small Signal Analysis under Radiation Effects

    Sharshar, K.A.A.

    2004-01-01

    A Small signal transistor parameters dedicate the operation of bipolar transistor before and after exposed to gamma radiation (1 Mrad up to 5 Mrads) and electron beam(1 MeV, 25 mA) with the same doses as a radiation sources, the electrical parameters of the device are changed. The circuit Model has been discussed.Parameters, such as internal emitter resistance (re), internal base resistance, internal collector resistance (re), emitter base photocurrent (Ippe) and base collector photocurrent (Ippe). These parameters affect on the operation of the device in its applications, which work as an effective element, such as current gain (hFE≡β)degradation it's and effective parameter in the device operation. Also the leakage currents (IcBO) and (IEBO) are most important parameters, Which increased with radiation doses. Theoretical representation of the change in the equivalent circuit for NPN and PNP bipolar transistor were discussed, the input and output parameters of the two types were discussed due to the change in small signal input resistance of the two types. The emitter resistance(re) were changed by the effect of gamma and electron beam irradiation, which makes a change in the role of matching impedances between transistor stages. Also the transistor stability factors S(Ico), S(VBE) and S(β are detected to indicate the transistor operations after exposed to radiation fields. In low doses the gain stability is modified due to recombination of induced charge generated during device fabrication. Also the load resistance values are connected to compensate the effect

  18. Radiation-resistant requirements analysis of device and control component for advanced spent fuel management process

    Song, Tai Gil; Park, G. Y.; Kim, S. Y.; Lee, J. Y.; Kim, S. H.; Yoon, J. S. [Korea Atomic Energy Research Institute, Taejeon (Korea)

    2002-02-01

    It is known that high levels of radiation can cause significant damage by altering the properties of materials. A practical understanding of the effects of radiation - how radiation affects various types of materials and components - is required to design equipment to operate reliably in a gamma radiation environment. When designing equipment to operate in a high gamma radiation environment, such as will be present in a nuclear spent fuel handling facility, several important steps should be followed. In order to active test of the advanced spent fuel management process, the radiation-resistant analysis of the device and control component for active test which is concerned about the radiation environment is conducted. Also the system design process is analysis and reviewed. In the foreign literature, 'threshold' values are generally reported. the threshold values are normally the dose required to begin degradation in a particular material property. The radiation effect analysis for the device of vol-oxidation and metalization, which are main device for the advanced spent fuel management process, is performed by the SCALE 4.4 code. 5 refs., 4 figs., 13 tabs. (Author)

  19. The personnel protection system for a Synchrotron Radiation Accelerator Facility: Radiation safety perspective

    Liu, J.C.

    1993-05-01

    The Personnel Protection System (PPS) at the Stanford Synchrotron Radiation Laboratory is summarized and reviewed from the radiation safety point of view. The PPS, which is designed to protect people from radiation exposure to beam operation, consists of the Access Control System (ACS) and the Beam Containment System (BCS), The ACS prevents people from being exposed to the very high radiation level inside the shielding housing (also called a PPS area). The ACS for a PPS area consists of the shielding housing and a standard entry module at every entrance. The BCS prevents people from being exposed to the radiation outside a PPS area due to normal and abnormal beam losses. The BCS consists of the shielding (shielding housing and metal shielding in local areas), beam stoppers, active current limiting devices, and an active radiation monitor system. The system elements for the ACS and BCS and the associated interlock network are described. The policies and practices in setting up the PPS are compared with some requirements in the US Department of Energy draft Order of Safety of Accelerator Facilities

  20. A systems approach to the management of radiation accidents

    Richter, L.L.; Berk, H.W.; Teates, C.D.; Larkham, N.E.; Friesen, E.J.; Edlich, R.F.

    1980-01-01

    Management of radiation accident patients should have a multidisciplinary approach that includes all health professionals as well as members of public safety agencies. Emergency plans for radiation accidents include detection of the ionizing radiation, patient evacuation, resuscitation, and decontamination. The resuscitated patient should be transported to a radiation control area located outside but adjacent to the emergency department. Ideally this area is accessed through an entrance separate from that used for the main flow of daily emergency department patients. The hospital staff, provided with protective clothing, dosimeters, and preprinted guidelines, continues the resuscitation and definitive care of the patient. This system approach to the management of radiation accidents may be tailored to meet the specific needs of other emergency medical systems

  1. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P

    2006-09-15

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO{sub 2} into U-metal. For demonstration of this process, {alpha}-{gamma} type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for {gamma}-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  2. Radiation Tolerant, FPGA-based SmallSat Computer System

    National Aeronautics and Space Administration — The goal of this project is to mature the technology readiness of a radiation tolerant smallsat computer system for a subsequent orbital flight demonstration. The...

  3. The Telemetric Early Warning Environmental Radiation Monitoring System of Cyprus

    Christofides, S [Medical Physics Department, Nicosia General Hospital, Nicosia (Cyprus)

    1998-12-31

    This paper presents the hardware design, the development of the software and the use of the Telemetric Early Warning Environmental Radiation Monitoring System (TEWERMS) of Cyprus. (author). 3 refs, 6 figs.

  4. Coherent scattering of electromagnetic radiation by a polarized particle system

    Agre, M.Ya.; Rapoport, L.P.

    1996-01-01

    The paper deals with the development of the theory of coherent scattering of electromagnetic waves by a polarized atom or molecular system. Peculiarities of the angular distribution and polarization peculiarities of scattered radiation are discussed

  5. RadNet (Environmental Radiation Ambient Monitoring System)

    U.S. Environmental Protection Agency — RadNet, formerly Environmental Radiation Ambient Monitoring System (ERAMS), is a national network of monitoring stations that regularly collect air, precipitation,...

  6. Radiation Monitoring System in Advanced Spent Fuel Conditioning Process Facility

    You, Gil Sung; Kook, D. H.; Choung, W. M.; Ku, J. H.; Cho, I. J.; You, G. S.; Kwon, K. C.; Lee, W. K.; Lee, E. P.

    2006-09-01

    The Advanced spent fuel Conditioning Process is under development for effective management of spent fuel by converting UO 2 into U-metal. For demonstration of this process, α-γ type new hot cell was built in the IMEF basement . To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hot cell and service area at back of it. This system consists of 7 parts; Area Monitor for γ-ray, Room Air Monitor for particulate and iodine in both area, Hot cell Monitor for hot cell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration

  7. VENTILATION TECHNOLOGY SYSTEMS ANALYSIS

    The report gives results of a project to develop a systems analysis of ventilation technology and provide a state-of-the-art assessment of ventilation and indoor air quality (IAQ) research needs. (NOTE: Ventilation technology is defined as the hardware necessary to bring outdoor ...

  8. Comparison and analysis of BNCT radiation dose between gold wire and JCDS measurement

    Kageji, T.; Mizobuchi, Y.; Nagahiro, S.; Nakagawa, Y.; Kumada, Hiroaki

    2006-01-01

    We compared and evaluated boron neutron capture therapy (BNCT) radiation dose between gold wire measurement and JAERI Computational Dosimetry System (JCDS). Gold wire analysis demonstrates the actual BNCT dose though it dose not reflect the real the maximum and minimum dose in tumor tissue. We can conclude that JCDS is precise and high-reliable dose planning system for BNCT. (author)

  9. Advances in radiation biology: Relative radiation sensitivities of human organ systems. Volume 12

    Lett, J.T.; Altman, K.I.; Ehmann, U.K.; Cox, A.B.

    1987-01-01

    This volume is a thematically focused issue of Advances in Radiation Biology. The topic surveyed is relative radiosensitivity of human organ systems. Topics considered include relative radiosensitivities of the thymus, spleen, and lymphohemopoietic systems; relative radiosensitivities of the small and large intestine; relative rediosensitivities of the oral cavity, larynx, pharynx, and esophagus; relative radiation sensitivity of the integumentary system; dose response of the epidermal; microvascular, and dermal populations; relative radiosensitivity of the human lung; relative radiosensitivity of fetal tissues; and tolerance of the central and peripheral nervous system to therapeutic irradiation

  10. Advances in radiation biology: Relative radiation sensitivities of human organ systems. Volume 12

    Lett, J.T.; Altman, K.I.; Ehmann, U.K.; Cox, A.B.

    1987-01-01

    This volume is a thematically focused issue of Advances in Radiation Biology. The topic surveyed is relative radiosensitivity of human organ systems. Topics considered include relative radiosensitivities of the thymus, spleen, and lymphohemopoietic systems; relative radiosensitivities of the small and large intestine; relative rediosensitivities of the oral cavity, larynx, pharynx, and esophagus; relative radiation sensitivity of the integumentary system; dose response of the epidermal; microvascular, and dermal populations; relative radiosensitivity of the human lung; relative radiosensitivity of fetal tissues; and tolerance of the central and peripheral nervous system to therapeutic irradiation.

  11. Genetic analysis of radiation-induced mouse thymic lymphomas

    Kominami, R.; Wakabayashi, Y.; Niwa, O.

    2003-01-01

    Mouse thymic lymphomas are one of the classic models of radiation-induced malignancies, and the model has been used for the study of genes involved in carcinogenesis. ras oncogenes are the first isolate which undergoes mutations in 10 to 30 % of lymphomas, and p16INK4a and p19ARF in the INK4a-ARF locus are also frequently inactivated. In our previous study, the inactivation of Ikaros, a key regurator of lymphoid system, was found in those lymphomas, and it was suggested that there are other responsible genes yet to be discovered. On the other hand, genetic predisposition to radiation-induced lymphoma often differs in different strains, and this reflects the presence of low penetrance genes that can modify the impact of a given mutation. Little study of such modifiers or susceptibility genes has been performed, either. Recent availability of databases on mouse genome information and the power of mouse genetic system underline usefulness of the lymphoma model in search for novel genes involved, which may provide clues to molecular mechanisms of development of the radiogenic lymphoma and also genes involved in human lymphomas and other malignancies. Accordingly, we have carried out positional cloning for the two different types of tumor-related genes. In this symposium, our current progress is presented that includes genetic mapping of susceptibility/ resistance loci on mouse chromosomes 4, 5 and 19, and also functional analysis of a novel tumor suppressor gene, Rit1/Bcl11b, that has been isolated from allelic loss (LOH) mapping and sequence analysis for γ -ray induced mouse thymic lymphomas

  12. Analysis of occupational doses of radiation workers in medical institutions

    Sanaye, S.S.; Baburajan, Sujatha; Joshi, V.D.; Pawar, S.G.; Nalawade, S.K.; Raman, N.V.; Kher, R.K.

    2007-01-01

    Routine monitoring of occupational radiation workers is done for controlling the doses to the individuals and to demonstrate the compliance with occupational dose limits. One of the objective of personnel monitoring program is the assessment of the radiation safety of working area and trends of exposure histories of individuals or group of workers. Computerised dose registry of all monitored radiation workers along with their personnel data helps in analyzing these trends. This in turn helps the institutions in management of their radiation safety programs. In India, annual and life time occupational dose records are maintained as National Dose Registry in the Radiological Physics and Advisory Division, Bhabha Atomic Research Centre. This paper presents analysis of occupational dose data of monitored radiation workers in medical institutions in India during last five years (i.e. 2002-2006)

  13. An Interfacing System for Radiation Surveillance Using a Radio Communication Network

    Arunsiri, T.; Punnachaiya, S.; Pattarasumun, A.

    1998-01-01

    The development of an interfacing system for environmental radiation surveillance using radio communication network is aimed to improve a way by which environmental radiation measurement is transmitted and reported from the regional area monitoring station network. This also includes an automatic warning of beacon status via the radio link network to the center of environmental radiation control when an abnormal radiation level is detected. The interfacing system was developed by simulating the EGAT radio link network, the NT 2612, and can be separated into two parts. The first part was for a mobile station which can manage the output data from the radiation measurement system in the standard form of RS-232, IEEE-488, BCD and analog signal. This was accomplished by modulating the signal in selected baud rates ranging from 150 to 9600 bps using an economical radio packet capable of identifying and recalling the station code number. The other part is the linking system between the output data and the microcomputer equipped with a software to manage and evaluate the data from 10 surveillance stations for convenient handing of data output, statistical analysis and transmitting warning signal. Data transmission was tested using a baud rate of 1200 bps and was found to contain no detectable error when digital signal was transmitted while analog signal transmission resulted in deviations of less than ± 0.003%. The development of this radio link system provides a future trend for the environmental radiation monitoring network for countries with nuclear power plants or neighboring countries needed to continuously monitor for any abnormal radiation level in the environment. In case that the radiation surveillance system detects a high level of radiation, a warning signal will be transmitted and appropriate actions may be immediately exercised to control impacts of radiation on environment and living things according to international guidelines

  14. Conference on Radiation and its Effects on Components and Systems

    2017-01-01

    The aim of RADECS conferences is to provide an annual European forum for the presentation and discussion of the latest advances in the field of radiation effects on electronic and photonic materials, devices, circuits, sensors, and systems. The scope of the conference encompasses technological processes and design techniques for producing radiation tolerant systems for space, aeronautical or terrestrial applications, as well as relevant methodologies for their characterization and qualification. The conference features a technical program, an Industrial Exhibit, and one day tutorial or ‘short course’ on radiation effects. The technical program includes oral and poster sessions and round tables.

  15. The Advanced Light Source (ALS) Radiation Safety System

    Ritchie, A.L.; Oldfather, D.E.; Lindner, A.F.

    1993-08-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 Gev synchrotron light source facility consisting of a 120 kev electron gun, 50 Mev linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. Figure 1. ALS floor plan. Pairs of neutron and gamma radiation monitors are shown as dots numbered from 1 to 12. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  16. Project Management of a personnel radiation records computer system

    Labenski, T.

    1984-01-01

    Project Management techniques have been used to develop a data base management information system to provide storage and retrieval of personnel radiation and Health Physics records. The system is currently being developed on a Hewlett Packard 1000 Series E Computer with provisions to include plant radiation survey information, radiation work permit information, inventory management for Health Physics supplies and instrumentation, and control of personnel access to radiological controlled areas. The methodologies used to manage the overall project are presented along with selection and management of software vendors

  17. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data

  18. Technical specifications manual for the MARK-1 pulsed ionizing radiation detection system. Volume 1

    Lawrence, R.S.; Harker, Y.D.; Jones, J.L.; Hoggan, J.M.

    1993-03-01

    The MARK-1 detection system was developed by the Idaho National Engineering Laboratory for the US Department of Energy Office of Arms Control and Nonproliferation. The completely portable system was designed for the detection and analysis of intense photon emissions from pulsed ionizing radiation sources. This manual presents the technical design specifications for the MARK-1 detection system and was written primarily to assist the support or service technician in the service, calibration, and repair of the system. The manual presents the general detection system theory, the MARK-1 component design specifications, the acquisition and control software, the data processing sequence, and the system calibration procedure. A second manual entitled: Volume 2: Operations Manual for the MARK-1 Pulsed Ionizing Radiation Detection System (USDOE Report WINCO-1108, September 1992) provides a general operational description of the MARK-1 detection system. The Operations Manual was written primarily to assist the field operator in system operations and analysis of the data.

  19. Hollow-duct radiation delivery system investigation

    Kramer D.

    2013-05-01

    Full Text Available Investigation of hollow-duct structure for high-power laser-diode-array radiation delivery into the end-pumped large-aperture gain media is reported. A ray tracing method has been used to evaluate the performance of the structure designed for maximum transmission efficiency and output beam profile homogeneity. Variable hollow-duct lengths as well as emanating angles of laser-diode-array have been taken into account.

  20. Test plan for Digface Chemical and Radiation Assay System

    Akers, D.W.

    1993-07-01

    The Digface Chemical and Radiation Assay System (CRAS) Project will develop a sensor using Prompt Gamma Neutron Activation Analysis (PGNAA) that can detect the present of hazardous chemicals and radioactive materials. The CRAS is being designed for in situ assay of closed drums and contaminated soils for gamma-ray emitting radionuclides and hazardous elements. The CRAS is based upon the use of 252 Cf PGNAA with a germanium gamma-ray spectrometer as the analyzer. Tasks being performed include determining detection limits for a number of hazardous chemicals and assessing matrix and transmission effects through soil. Initial analyses suggest that the technique is applicable to a number of hazardous materials such as trichloroethane and carbon tetrachloride

  1. Development of radiation hard components for ITER blanket remote handling system

    Saito, Makiko, E-mail: saito.makiko@jaea.go.jp; Anzai, Katsunori; Maruyama, Takahito; Noguchi, Yuto; Ueno, Kenichi; Takeda, Nobukazu; Kakudate, Satoshi

    2016-11-01

    Highlights: • Clarify the components that will degrade by gamma ray irradiation. • Perform the irradiation tests to BRHS components. • Optimize the materials to increase the radiation hardness. - Abstract: The ITER blanket remote handling system (BRHS) will be operated in a high radiation environment (250 Gy/h max.) and must stably handle the blanket modules, which weigh 4.5 t and are more than 1.5 m in length, with a high degree of position and posture accuracy. The reliability of the system can be improved by reviewing the failure events of the system caused by high radiation. A failure mode and effects analysis (FMEA) identified failure modes and determined that lubricants, O-rings, and electric insulation cables were the dominant components affecting radiation hardness. Accordingly, we tried to optimize the lubricants and cables of the AC servo motors by using polyphenyl ether (PPE)-based grease and polyether ether ketone (PEEK), respectively. Materials containing radiation protective agents were also selected for the cable sheaths and O-rings to improve radiation hardness. Gamma ray irradiation tests were performed on these components and as a result, a radiation hardness of 8 MGy was achieved for the AC servo motors. On the other hand, to develop the radiation hardness and BRHS compatibility furthermore, the improvement of materials of cable and O ring were performed.

  2. The Austrian system for the measurement of environmental radioactivity (ASMER) and the Austrian early radiation warning system (AERWS)

    Henrich, E.

    1988-01-01

    The two systems of environment radiation measurements complement each other. ASMER does a detailed, quantitative and nuclide specific analysis of the contaminations in the environment. AERWS's aim is to alarm the authorities in case of accident. It is aimed at higher radiation levels is not nuclide specific but quick. A short description is given of the organisations concerned, the procedures used and items surveyed by the two networks. 8 refs., 19 figs. (qui)

  3. Radiation and chemically induced potentially lethal lesions in noncycling mammalian cells: recovery analysis in terms of x-ray- and ultraviolet-like-systems

    Hahn, G.M.

    1975-01-01

    Recovery from and fixation of potentially lethal damage after exposure of Chinese hamster cells to uv and to x irradiation were investigated, as was recovery after exposure to chemotherapeutic agents. Recovery after uv radiation has a T/sub 1 / 2 / of about 20 hr; the fraction of cells able to undergo recovery depends upon nutritional factors both before and after exposure. After x irradiation, recovery proceeds with a T/sub 1 / 2 / of approximately 2 hr and is much less influenced by nutritional factors. Fixation after serum stimulation has a T/sub 1 / 2 / of 3 to 4 hr in uv-irradiated cells, a T/sub 1 / 2 / of 30 min in x-irradiated cells. Recovery kinetics after nitrogen mustard and bleomycin exposures mimic those for x-ray exposure; after methyl methane sulfonate the kinetics are mainly uv-like, though with an x-ray-like component. Recovery by cells with BUdR-substituted DNA and irradiated with visible light is primarily x-ray-like, though with a uv-like component. There is no recovery by cells exposed to adriamycin or to 1,3-bis(2-chloroethyl)-1-nitrosourea

  4. Integration of video and radiation analysis data

    Menlove, H.O.; Howell, J.A.; Rodriguez, C.A.; Eccleston, G.W.; Beddingfield, D.; Smith, J.E.; Baumgart, C.W.

    1995-01-01

    For the past several years, the integration of containment and surveillance (C/S) with nondestructive assay (NDA) sensors for monitoring the movement of nuclear material has focused on the hardware and communications protocols in the transmission network. Little progress has been made in methods to utilize the combined C/S and NDA data for safeguards and to reduce the inspector time spent in nuclear facilities. One of the fundamental problems in the integration of the combined data is that the two methods operate in different dimensions. The C/S video data is spatial in nature; whereas, the NDA sensors provide radiation levels versus time data. The authors have introduced a new method to integrate spatial (digital video) with time (radiation monitoring) information. This technology is based on pattern recognition by neural networks, provides significant capability to analyze complex data, and has the ability to learn and adapt to changing situations. This technique has the potential of significantly reducing the frequency of inspection visits to key facilities without a loss of safeguards effectiveness

  5. Estimation and analysis of spectral solar radiation over Cairo

    Abdel Wahab, M.M.; Omran, M.

    1994-05-01

    This work presents a methodology to estimate spectral diffuse and global radiation on horizontal surface. This method is validated by comparing with measured direct and global spectral radiation in four bands. The results show a good performance in cloudless conditions. The analysis of the ratio of surface values to extraterrestrial ones revealed an over-all depletion in the summer months. Also there was no evidence for any tendency for conversion of radiational components through different bands. The model presents excellent agreement with the measured values for (UV/G) ratio. (author). 7 refs, 4 figs, 3 tabs

  6. Composite waste analysis system

    Wachter, J.R.; Hagan, R.C.; Bonner, C.A.; Malcom, J.E.; Camp, K.L.

    1993-01-01

    Nondestructive analysis (NDA) of radioactive waste forms an integral component of nuclear materials accountability programs and waste characterization acceptance criterion. However, waste measurements are often complicated by unknown isotopic compositions and the potential for concealment of special nuclear materials in a manner that is transparent to gamma-ray measurement instruments. To overcome these complications, a new NDA measurement system has been developed to assay special nuclear material in both transuranic and low level waste from the same measurement platform. The system incorporates a NaI detector and customized commercial software routines to measure small quantities of radioactive material in low level waste. Transuranic waste analysis is performed with a coaxial HPGE detector and uses upgraded PC-based segmented gamma scanner software to assay containers up to 55 gal. in volume. Gamma-Ray isotopics analysis of both waste forms is also performed with this detector. Finally, a small neutron counter using specialized software is attached to the measurement platform to satisfy safeguards concerns related to nuclear materials that are not sensed by the gamma-ray instruments. This report describes important features and capabilities of the system and presents a series of test measurements that are to be performed to define system parameters

  7. Actinide isotopic analysis systems

    Koenig, Z.M.; Ruhter, W.D.; Gunnink, R.

    1990-01-01

    This manual provides instructions and procedures for using the Lawrence Livermore National Laboratory's two-detector actinide isotope analysis system to measure plutonium samples with other possible actinides (including uranium, americium, and neptunium) by gamma-ray spectrometry. The computer program that controls the system and analyzes the gamma-ray spectral data is driven by a menu of one-, two-, or three-letter options chosen by the operator. Provided in this manual are descriptions of these options and their functions, plus detailed instructions (operator dialog) for choosing among the options. Also provided are general instructions for calibrating the actinide isotropic analysis system and for monitoring its performance. The inventory measurement of a sample's total plutonium and other actinides content is determined by two nondestructive measurements. One is a calorimetry measurement of the sample's heat or power output, and the other is a gamma-ray spectrometry measurement of its relative isotopic abundances. The isotopic measurements needed to interpret the observed calorimetric power measurement are the relative abundances of various plutonium and uranium isotopes and americium-241. The actinide analysis system carries out these measurements. 8 figs

  8. Network systems security analysis

    Yilmaz, Ä.°smail

    2015-05-01

    Network Systems Security Analysis has utmost importance in today's world. Many companies, like banks which give priority to data management, test their own data security systems with "Penetration Tests" by time to time. In this context, companies must also test their own network/server systems and take precautions, as the data security draws attention. Based on this idea, the study cyber-attacks are researched throughoutly and Penetration Test technics are examined. With these information on, classification is made for the cyber-attacks and later network systems' security is tested systematically. After the testing period, all data is reported and filed for future reference. Consequently, it is found out that human beings are the weakest circle of the chain and simple mistakes may unintentionally cause huge problems. Thus, it is clear that some precautions must be taken to avoid such threats like updating the security software.

  9. Radiation analysis in the major areas of marine fisheries research

    Murty, A.V.S.

    1975-01-01

    Radiation analysis has been a proven technique to solve, relatively easily and quickly, some of the pressing problems in marine fisheries to the utmost satisfaction. Major areas of marine fisheries research - namely, the determination of sea water characteristics, the productivity studies, the pollution effects, the population dynamics and the preservation of sea foods - wherein the radiation treatment is fully helpful are discussed in detail. The problems encountered in the marine fisheries in India in this context are also outlined. (author)

  10. Automated analysis of damages for radiation in plastics surfaces

    Andrade, C.; Camacho M, E.; Tavera, L.; Balcazar, M.

    1990-02-01

    Analysis of damages done by the radiation in a polymer characterized by optic properties of polished surfaces, of uniformity and chemical resistance that the acrylic; resistant until the 150 centigrade grades of temperature, and with an approximate weight of half of the glass. An objective of this work is the development of a method that analyze in automated form the superficial damages induced by radiation in plastic materials means an images analyst. (Author)

  11. Radiation induced effects in the developing central nervous system

    Gisone, P.; Dubner, D.; Michelin, S.C.; Perez, M.R. Del

    1997-01-01

    The embryo and the human foetus are particularly sensitive to ionizing radiation and this sensitivity presents various qualitative and quantitative functional changes during intra-uterine development. Apart from radiation induced carcinogenesis, the most serious consequence of prenatal exposure in human beings is severe mental retardation. The principal data on radiation effects on human beings in the development of the central nervous system come form epidemiological studies carried out in individuals exposed in utero during the atomic explosion at Hiroshima and Nagasaki. These observations demonstrate the existence of a time of maximum radiosensitivity between the weeks 8 and 15 of the gestational period, a period in which the proliferation and neuronal migration takes place. Determination of the characteristics of dose-response relationship and the possible existence of a threshold dose of radiation effects on the development of the central nervous system is relevant to radiation protection against low dose radiation and the establishment of dose limits for occupational exposure and the public. Studies were conducted on the generation of nitrous-oxide and its relation with the production of active species of oxygen in brains of exposed rats in utero exposed to doses of up to 1 Gy during their maximum radiosensitivity. The possible role of the mechanism of radiation induced damage in the development of the central nervous system is discussed

  12. Activities of the Institute of Radiation Protection and Dosimetry on radiation overexposure analysis - results from 1994 to 1997

    Silva, Francisco C.A. da; Ramalho, Adriana

    1999-01-01

    Since 1985 the Institute of Radiation Protection and Dosimetry has operated a service carried out by a multi-disciplinary Group called Radiation Overexposure analysis Group - GADE. It is composed of specialists in radiation protection and dosimetry and has the main objective of taking coordinated actions on radiation overexposure cases. This paper shows mainly the results got from 1984 to 1997 with the methodology used. It was observed that the cases are falling down due to radiation protection activities in the installation. (author)

  13. Investigation of thermal and hydrodynamic processes in the oil transformer radiator cooling system

    Ільїн, Сергій Віталійович

    2013-01-01

    Despite the large number of publications in the field of transformer, heat transfer and hydrodynamic processes that take place in the radiator cooling systems, lack of attention. However, for a comprehensive analysis of the entire oil circuit in the transformer, it is necessary to take into account the work of the radiator, as it was on the efficiency of removal of heat in it will depend on the oil temperature at the inlet of the transformer. To achieve these objectives, this paper describes ...

  14. A system of radiation monitoring, and methods and equipment for measuring water of low specific activity

    Sivintsev, Yu.V.

    1975-01-01

    The author considers criteria for the radiation protection of the population and the environment. He describes the role of procedures for monitoring waters of low specific activity in the framework of a system for ensuring the radiation safety of the population living near a nuclear power station. The main technical characteristics (background, efficiency, sensitivity) of the laboratory equipment for gamma spectrometric analysis of water samples of low specific activity are discussed. (author)

  15. Stochastic biological response to radiation. Comprehensive analysis of gene expression

    Inoue, Tohru; Hirabayashi, Yoko

    2012-01-01

    Authors explain that the radiation effect on biological system is stochastic along the law of physics, differing from chemical effect, using instances of Cs-137 gamma-ray (GR) and benzene (BZ) exposures to mice and of resultant comprehensive analyses of gene expression. Single GR irradiation is done with Gamma Cell 40 (CSR) to C57BL/6 or C3H/He mouse at 0, 0.6 and 3 Gy. BE is given orally at 150 mg/kg/day for 5 days x 2 weeks. Bone marrow cells are sampled 1 month after the exposure. Comprehensive gene expression is analyzed by Gene Chip Mouse Genome 430 2.0 Array (Affymetrix) and data are processed by programs like case normalization, statistics, network generation, functional analysis etc. GR irradiation brings about changes of gene expression, which are classifiable in common genes variable commonly on the dose change and stochastic genes variable stochastically within each dose: e.g., with Welch-t-test, significant differences are between 0/3 Gy (dose-specific difference, 455 pbs (probe set), in stochastic 2113 pbs), 0/0.6 Gy (267 in 1284 pbs) and 0.6/3 Gy (532 pbs); and with one-way analysis of variation (ANOVA) and hierarchial/dendrographic analyses, 520 pbs are shown to involve the dose-dependent 226 and dose-specific 294 pbs. It is also shown that at 3 Gy, expression of common genes are rather suppressed, including those related to the proliferation/apoptosis of B/T cells, and of stochastic genes, related to cell division/signaling. Ven diagram of the common genes of above 520 pbs, stochastic 2113 pbs at 3 Gy and 1284 pbs at 0.6 Gy shows the overlapping genes 29, 2 and 4, respectively, indicating only 35 pbs are overlapping in total. Network analysis of changes by GR shows the rather high expression of genes around hub of cAMP response element binding protein (CREB) at 0.6 Gy, and rather variable expression around CREB hub/suppressed expression of kinesin hub at 3 Gy; in the network by BZ exposure, unchanged or low expression around p53 hub and suppression

  16. Analysis of reactor cavity radiation streaming: some practical considerations

    Simmons, G.L.

    1979-01-01

    A description is presented of a cost effective analysis procedure for use in the prediction of radiation environments in the cavity and containment building of a nuclear power reactor. Comments are offered on potential problems in certification of analysis procedures and the availability of benchmarkable data sets, both measurements and calculations

  17. Spectral Analysis Method of Plastic Scintillator-based Radiation Detector against Nuclear/Radiological Terrorism

    Kwak, Sung-Woo; Yoo, Ho-Sik; Jang, Sung Soon; Kim, Jung-Soo; Yoon, Wan-Ki

    2008-01-01

    In these days, the threats relating to nuclear or radioactive materials have become a matter of internationally increased grave concern. A plastic scintillation detector in radiation portal monitoring (RPM) application has been used to detect radioactive sources in steel scrap entering reprocessing facilities, and to detect illicit transport of radioactive material across border ports-of-entry. The detection systems for RPM application usually are large and can not easily be moved to a different location. For some situations, an inconspicuous and mobile system for the radioactive or nuclear material during road transport is needed. The mobile radiation detection system has employed a NaI- based radiation detector to detect and identify the material hidden in vehicle. There are some operational constraints - short measuring time, weak activity due to heavy shield of illegal source, long distance - of inspection system in such nuclear security applications. Due to these constraints, large area sensor is required to maximize its sensitivity. Large NaI material, however, is extremely expensive. In designing a radiation detector for prevention of illicit trafficking of nuclear or radioactive materials, the trade-off should be carefully optimized between performance and cost in order to achieve cost-effective inspection system. For the cost-effective mobile radiation detection system, this paper describes new spectral analysis method to use the crude spectroscopic information available from a plastic detector to discriminate other man-made radiation source from NORM

  18. Radiation protection of vitamins in aqueous systems

    Kishore, K.; Moorthy, P.N.; Rao, K.N.

    1976-01-01

    Thiamine and other vitamins of the B complex group are highly sensitive to γ radiation in aqueous solution owing to their high reactivity with the primary species formed by radiolysis of water, viz. hydrated electrons and hydroxyl radicals. In order to protect these compounds from radiolytic degradation, nitrous oxide and oxygen have been used as scavengers for the hydrated electrons and glucose for the hydroxyl radicals. By comparison of uv spectra it is shown that the above vitamins do not undergo radiolytic degradation in presence of nitrous oxide and glucose or oxygen and glucose. The importance of these results in connection with the sterilization of vitamin preparations is discussed. (author)

  19. ROC Analysis for Evaluation of Radiation Biodosimetry Technologies

    Williams, Benjamin B.; Swartz, Harold M.; Flood, Ann Barry; Demidenko, Eugene

    2016-01-01

    Receiver operating characteristic (ROC) analysis is a fundamental tool used for the evaluation and comparison of diagnostic systems that provides estimates of the combinations of sensitivity and specificity that can be achieved with a given technique. Along with critical considerations of practical limitations, such as throughput and time to availability of results, ROC analyses can be applied to provide meaningful assessments and comparisons of available biodosimetry methods. Accordingly, guidance from the Food and Drug Administration to evaluate biodosimetry devices recommends using ROC analysis. However, the existing literature for the numerous biodosimetry methods that have been developed to address the needs for triage either do not contain ROC analyses or present ROC analyses where the dose distributions of the study samples are not representative of the populations to be screened. The use of non-representative sample populations can result in a significant spectrum bias, where estimated performance metrics do not accurately characterize the true performance under real-world conditions. Particularly, in scenarios where a large group of people is screened because they were potentially exposed in a large-scale radiation event, directly measured population data do not exist. However, a number of complex simulations have been performed and reported in the literature that provide estimates of the required dose distributions. Based on these simulations and reported data about the output and uncertainties of biodosimetry assays, we illustrate how ROC curves can be generated that incorporate a realistic representative sample. A technique to generate ROC curves for biodosimetry data is presented along with representative ROC curves, summary statistics and discussion based on published data for triage-ready electron paramagnetic resonance in vivo tooth dosimetry, the dicentric chromosome assay and quantitative polymerase chain reaction assay. We argue that this

  20. Development of multi copter based autonomous unmanned aerial radiation monitoring system for the remote impact assessment of radiation emergencies

    Jose, Jis Romal; Gupta, Ashutosh; Bahadur, Shuchita; Chaudhury, Probal; Pradeepkumar, K.S.

    2016-01-01

    During any radiation emergency, the level and extent of radioactive contamination need to be monitored for the timely and effective implementation of countermeasures to reduce the radiation exposure to public. In such a scenario, radiation surveillance can be carried out using either ground based mobile monitoring techniques or aerial radiation monitoring. Aerial radiation monitoring is quick and capable of scanning the areas which are not easily accessible by the ground based mobile monitoring. Compact unmanned aerial vehicle based radiation surveillance system is ideal in above mentioned radiation emergency scenarios as it can be rapidly deployed in the affected area and radiation exposure to the monitoring personal can be totally avoided. This paper describes development of multi copter based autonomous unmanned aerial radiation monitoring system for the remote impact assessment of radiation emergencies

  1. Development Of Data Acquisition Software For Centralized Radiation Monitoring System

    Nolida Yussup; Maslina Mohd Ibrahim; Mohd Fauzi Haris; Syirrazie Che Soh; Harzawardi Hasim; Azraf Azman; Mohd Ashhar Khalid

    2014-01-01

    Nowadays, with the growth of technology, many devices and equipment's can be connected to the network and internet to enable online data acquisition. Centralized radiation monitoring system utilizes a Local Area Network (LAN) as a communication media for data acquisition of the area radiation levels from radiation detectors in Malaysian Nuclear Agency (Nuclear Malaysia). The development of the system involves device configuration, wiring, network and hardware installation, software and web development. This paper describes the software development on the system server that is responsible to acquire and record the area radiation readings from the detectors. Then the recorded readings are called in a web programming to be displayed on a web site. The readings with the time stamp are stored in the system database for query. Besides acquiring the area radiation levels in Nuclear Malaysia centrally, additional features such as data conversion from mR to μSv and line chart display are developed in the software for effective radiation level trend observation and studies. (author)

  2. Management information system applied to radiation protection services

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur

    2013-01-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  3. Management information system applied to radiation protection services

    Grossi, Pablo Andrade; Souza, Leonardo Soares de; Figueiredo, Geraldo Magela; Figueiredo, Arthur, E-mail: pabloag@cdtn.br, E-mail: lss@cdtn.br, E-mail: gmf@cdtn.br, E-mail: arthurqof@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    An effective management information system based on technology, information and people is necessary to improve the safety on all processes and operations subjected to radiation risks. The complex and multisource information flux from all radiation protection activities on nuclear organizations requires a robust tool/system to highlight the strengths and weaknesses and identify behaviors and trends on the activities requiring radiation protection programs. Those organized and processed data are useful to reach a successful management and to support the human decision-making on nuclear organization. This paper presents recent improvements on a management information system based on the radiation protection directives and regulations from Brazilian regulatory body. This radiation protection control system is applied to any radiation protection services and research institutes subjected to Brazilian nuclear regulation and is a powerful tool for continuous management, not only indicating how the health and safety activities are going, but why they are not going as well as planned showing up the critical points. (author)

  4. Understanding of radiation protection in medicine. Pt. 2. Occupational exposure and system of radiation protection

    Iida, Hiroji; Yamamoto, Tomoyuki; Shimada, Yasuhiro

    1997-01-01

    Using a questionnaire we investigated whether radiation protection is correctly understood by medical doctors (n=140) and nurses (n=496). Although medical exposure is usually understood by medical doctors and dentists, their knowledge was found to be insufficient. Sixty-eight percent of medical doctors and 50% of dentists did not know about the system of radiation protection. Dose monitoring was not correctly carried out by approximately 20% of medical staff members, and medical personnel generally complained of anxiety about occupational exposure rather than medical exposure. They did not receive sufficient education on radiation exposure and protection in school. In conclusion, the results of this questionnaire suggested that they do not have adequate knowledge about radiation exposure and protection. The lack of knowledge about protection results in anxiety about exposure. To protect oneself from occupational exposure, individual radiation doses must be monitored, and medical practice should be reconsidered based on the results of monitoring. To eliminate unnecessary medical and occupational exposure and to justify practices such as radiological examinations, radiation protection should be well understood and appropriately carried out by medical doctors and dentists. Therefore, the education of medical students on the subject of radiation protection is required as is postgraduate education for medical doctors, dentists and nurses. (author)

  5. Online radiation dose measurement system for ATLAS experiment

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Mikuz, M. [Jozef Stefan Institute, Jamova 39, Ljubljana (Slovenia); Faculty of Mathematics and Physics, University of Ljubljana (Slovenia); Bronner, J.; Hartet, J. [Physikalisches Institut, Universitat Freiburg, Hermann-Herder-Str. 3, Freiburg (Germany); Franz, S. [CERN, Geneva (Switzerland)

    2009-07-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO{sub 2} will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10{sup 9} n/cm{sup 2} for NIEL (non-ionizing energy loss) measurements, 10{sup 12} n/cm{sup 2} for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  6. Online radiation dose measurement system for ATLAS experiment

    Mandic, I.; Cindro, V.; Dolenc, I.; Gorisek, A.; Kramberger, G.; Mikuz, M.; Bronner, J.; Hartet, J.; Franz, S.

    2009-01-01

    In experiments at Large Hadron Collider, detectors and electronics will be exposed to high fluxes of photons, charged particles and neutrons. Damage caused by the radiation will influence performance of detectors. It will therefore be important to continuously monitor the radiation dose in order to follow the level of degradation of detectors and electronics and to correctly predict future radiation damage. A system for online radiation monitoring using semiconductor radiation sensors at large number of locations has been installed in the ATLAS experiment. Ionizing dose in SiO 2 will be measured with RadFETs, displacement damage in silicon in units of 1-MeV(Si) equivalent neutron fluence with p-i-n diodes. At 14 monitoring locations where highest radiation levels are expected the fluence of thermal neutrons will be measured from current gain degradation in dedicated bipolar transistors. The design of the system and tests of its performance in mixed radiation field is described in this paper. First results from this test campaign confirm that doses can be measured with sufficient sensitivity (mGy for total ionizing dose measurements, 10 9 n/cm 2 for NIEL (non-ionizing energy loss) measurements, 10 12 n/cm 2 for thermal neutrons) and accuracy (about 20%) for usage in the ATLAS detector

  7. Radiation-induced tumors of the nervous system

    Bernstein, M.; Laperriere, N.

    1991-01-01

    Therapeutic and nontherapeutic ionizing radiation has long been recognized as a putative carcinogenic agent, but the evidence that radiation causes tumors is circumstantial at worst and statistically significant at best. There are no distinct histological, biochemical, cytogenetic, or clinical criteria that can be used to determine if an individual tumor was caused directly by previous irradiation of the anatomic area. Additional supportive evidence for radiation-induced tumors includes a position correlation between radiation dose and tumor incidence (usually in the low dose range) and experimental induction of the same neoplasm in appropriate animal models. even if these criteria are fulfilled, coincidental development of a second tumor can never be discounted in an individual patient, particularly if there is an underlying diathesis to develop multiple tumors of different histology, such as in Recklinghausen's disease, or if there is an strong family history for the development of neoplastic disease. In this paper, the authors critically evaluate the available evidence to support the hypothesis that radiation induces tumors in the nervous system. The current concepts of radiation carcinogenesis are discussed and are followed by a discussion of animal data and clinical experience in humans. Finally, a brief discussion on treatment of radiation-induced nervous system tumors is presented

  8. Los Alamos radiation transport code system on desktop computing platforms

    Briesmeister, J.F.; Brinkley, F.W.; Clark, B.A.; West, J.T.

    1990-01-01

    The Los Alamos Radiation Transport Code System (LARTCS) consists of state-of-the-art Monte Carlo and discrete ordinates transport codes and data libraries. These codes were originally developed many years ago and have undergone continual improvement. With a large initial effort and continued vigilance, the codes are easily portable from one type of hardware to another. The performance of scientific work-stations (SWS) has evolved to the point that such platforms can be used routinely to perform sophisticated radiation transport calculations. As the personal computer (PC) performance approaches that of the SWS, the hardware options for desk-top radiation transport calculations expands considerably. The current status of the radiation transport codes within the LARTCS is described: MCNP, SABRINA, LAHET, ONEDANT, TWODANT, TWOHEX, and ONELD. Specifically, the authors discuss hardware systems on which the codes run and present code performance comparisons for various machines

  9. Environmental radiation monitoring system in nuclear power station

    Matsuoka, Sadazumi; Tadachi, Katsuo; Endo, Mamoru; Yuya, Hiroshi

    1983-01-01

    At the time of the construction of nuclear power stations, prior to their start of operation, the state of environmental radiation must be grasped. After the start of the power stations, based on those data, the system of environmental radiation monitoring is established. Along with the construction of Kashiwazaki-Kariwa Nuclear Power Station, The Tokyo Electric Power Co., Inc. jointly with Fujitsu Ltd. has developed a high-reliability, environmental radiation monitoring system, and adopted ''optical data highways'' using optical fiber cables for communication. It consists of a central monitoring station and 11 telemeter observation points, for collecting both radiation and meteorological data. The data sent to the central station through the highways are then outputted on a monitoring panel. They are analyzed with a central processor, and the results are printed out. (Mori, K.)

  10. Flow cytometric life cycle analysis in cellular radiation biology

    Wood, J.C.S.

    1982-01-01

    Three approaches to flow cytometric histogram analysis were developed: (1) differential histogram analysis, (2) DNA histogram analysis, and (3) multiparameter data analysis. These techniques were applied to an important unresolved problem in radiation biology. The initial responses to irradiation of a mammalian cell which occur during the first two cell cycles following the irradiation are of considerable interest to the radiation biologist. During the first two post-irradiation cell cycles, cells which ultimately will survive repair radiation-induced damage, while some cells begin to express some of the radiation-induced nuclear and chomatin damage. Caffeine- and thymidine-treated, and untreated gamma-irradiated cell populations were studied with respect to the radiation-induced G2 delay, deficient DNA synthesis, and the appearance of cells with abnormal DNA contents. It is hypothesized that the measured deficiency in DNA synthesis observed in the first post-irradiation cell cycle may be a result of daughter cells from abnormal first post-irradiation mitoses

  11. The role of radiation damage analysis in the fusion program

    Doran, D.G.

    1983-01-01

    The objective of radiation damage analysis is the prediction of the performance of facility components exposed to a radiation environment. The US Magnetic Fusion Energy materials program includes an explicit damage analysis activity within the Damage Analysis and Fundamental Studies (DAFS) Program. Many of the papers in these Proceedings report work done directly or indirectly in support of the DAFS program. The emphasis of this program is on developing procedures, based on an understanding of damage mechanisms, for applying data obtained in diverse radiation environments to the prediction of component behavior in fusion devices. It is assumed that the Fusion Materials Irradiation Test Facility will be available in the late 1980s to test (and calibrate where necessary) correlation procedures to the high fluences expected in commercial reactors. (orig.)

  12. Examination system utilizing ionizing radiation and a flexible, miniature radiation detector probe

    Majewski, Stanislaw; Kross, Brian J.; Zorn, Carl J.; Majewski, Lukasz A.

    1996-01-01

    An optimized examination system and method based on the Reverse Geometry X-Ray.RTM. (RGX.RTM.) radiography technique are presented. The examination system comprises a radiation source, at least one flexible, miniature radiation detector probe positioned in appropriate proximity to the object to be examined and to the radiation source with the object located between the source and the probe, a photodetector device attachable to an end of the miniature radiation probe, and a control unit integrated with a display device connected to the photodetector device. The miniature radiation detector probe comprises a scintillation element, a flexible light guide having a first end optically coupled to the scintillation element and having a second end attachable to the photodetector device, and an opaque, environmentally-resistant sheath surrounding the flexible light guide. The probe may be portable and insertable, or may be fixed in place within the object to be examined. An enclosed, flexible, liquid light guide is also presented, which comprises a thin-walled flexible tube, a liquid, preferably mineral oil, contained within the tube, a scintillation element located at a first end of the tube, closures located at both ends of the tube, and an opaque, environmentally-resistant sheath surrounding the flexible tube. The examination system and method have applications in non-destructive material testing for voids, cracks, and corrosion, and may be used in areas containing hazardous materials. In addition, the system and method have applications for medical and dental imaging.

  13. Safety of natural radiation exposure. A meta-analysis of epidemiological studies on natural radiation

    Osaki, S.

    2000-01-01

    . Furthermore, the combine of these studies, a meta-analysis, is expected to decrease the confidence limit and to countervail the confounding factors. This study reviewed the epidemiological studies on natural radiation exposure and tried to combine their results to prove the safety of natural radiation exposure. (author)

  14. 'RECASS'. Radioecological analysis support system

    Shershakov, V.

    1998-01-01

    The RECASS is developed as a computer system designed for radiation monitoring and decision-making support in a nuclear emergency. The RECASS system has excellent capabilities for collecting, storing, and presenting data from the radiological situation of contaminated areas. It is well designed for modeling radionuclide migration in the environmental media and for assessing countermeasures in terms of doses received by population groups as a result of radioactive contamination. For RECASS to be used as a basis for solving the problems of radioecological analysis, it is essential that mapping facilities are provided and that scaling capabilities allow data to be presented with the necessary degree of detail and accuracy. Because of the on-line links with the operating network of radiological monitoring, RECASS is capable of collecting meteorological and radiological data from across the country and storing this information in its databases. The availability of data from the network of radiological monitoring makes it possible to develop RECASS as a real-time emergency response system. (R.P.)

  15. Optical systems for synchrotron radiation. Lecture 2. Mirror systems

    Howells, M.R.

    1986-02-01

    The process of reflection of VUV and x-radiation is summarized. The functions of mirrors in synchrotron beamlines are described, which include deflection, filtration, power absorption, formation of a real image, focusing, and collimation. Fabrication of optical surfaces for synchrotron radiation beamlines are described, and include polishing of a near spherical surface as well as bending a cylindrical surface to toroidal shape. The imperfections present in mirrors, aberrations and surface figure inaccuracy, are discussed. Calculation of the thermal load of a mirror in a synchrotron radiation beam and the cooling of the mirror are covered briefly. 50 refs., 7 figs

  16. Gerald: a general environment for radiation analysis and design

    Boyle, Ch.; Oliveira, P.I.E. de; Oliveira, C.R.E. de; Adams, M.L.; Galan, J.M.

    2005-01-01

    Full text of publication follows: This paper describes the status of the GERALD interactive workbench for the analysis of radiation transport problems. GERALD basically guides the user through the various steps that are necessary to solve a radiation transport problem, and is aimed at education, research and industry. The advantages of such workbench are many: quality assurance of problem setup, interaction of the user with problem solution, preservation of theory and legacy research codes, and rapid proto-typing and testing of new methods. The environment is of general applicability catering for analytical, deterministic and stochastic analysis of the radiation problem and is not tied to one specific solution method or code. However, GERALD is being developed as a portable, modular, open source framework which renders itself quite naturally to the coupling of existing computational tools through specifically developed plug-ins. By offering a common route for setting up, solving and analyzing radiation transport problems GERALD offers the possibility of methods intercomparison and validation. Such flexible radiation transport environment will also facilitate the coupling of radiation physics methods to other physical phenomena and their application to other areas of application such as medical physics and the environment. (authors)

  17. Emergency response and radiation monitoring systems in Russian regions

    Arutyunyan, R.; Osipiyants, I.; Kiselev, V.; Ogar, K; Gavrilov, S.

    2008-01-01

    Full text: Preparedness of the emergency response system to elimination of radiation incidents and accidents is one of the most important elements of ensuring safe operation of nuclear power facilities. Routine activities on prevention of emergency situations along with adequate, efficient and opportune response actions are the key factors reducing the risks of adverse effects on population and environment. Both high engineering level and multiformity of the nuclear branch facilities make special demands on establishment of response system activities to eventual emergency situations. First and foremost, while resolving sophisticated engineering and scientific problems emerging during the emergency response process, one needs a powerful scientific and technical support system.The emergency response system established in the past decade in Russian nuclear branch provides a high efficiency of response activities due to the use of scientific and engineering potential and experience of the involved institutions. In Russia the responsibility for population protection is imposed on regional authority. So regional emergence response system should include up-to-date tools of radiation monitoring and infrastructure. That's why new activities on development of radiation monitoring and emergency response system were started in the regions of Russia. The main directions of these activities are: 1) Modernization of the existing and setting-up new facility and territorial automatic radiation monitoring systems, including mobile radiation surveillance kits; 2) Establishment of the Regional Crisis Centres and Crisis Centres of nuclear and radiation hazardous facilities; 3) Setting up communication systems for transfer, acquisition, processing, storage and presentation of data for participants of emergency response at the facility, regional and federal levels; 4) Development of software and hardware systems for expert support of decision-making on protection of personnel, population

  18. (Radiation carcinogenesis in the whole body system)

    Fry, R.J.M.

    1990-12-14

    The objectives of the trip were: to take part in and to give the summary of a Symposium on Radiation Carcinogenesis at Tokyo, and to give a talk at the National Institute of Radiological Sciences at Chiba. The breadth of the aspects considered at the conference was about as broad as is possible, from effects at the molecular level to human epidemiology, from the effects of tritium to cancer induction by heavy ions. The events induced by cancer that lead to cancer and the events that are secondary are beginning to come into better focus but much is still not known. Interest in suppressor genes is increasing rapidly in the studies of human tumors and many would predict that the three or four suppressor genes associated with cancer are only the first sighting of a much larger number.

  19. Proportional counter system for radiation measurement

    Sugimoto, M; Okudera, S

    1970-11-21

    A gas such as Xe or Kr employed in counter tubes is charged into the counter tube of a gas-flow type proportional counter for radiation measurement and into a vessel having a volume larger than that of the counter tube. The vessel communicates with the counter tube to circulate the gas via a pump through both the vessel and tube during measurement. An organic film such as a polyester synthetic resin film is used for the window of the counter tube to measure X-rays in the long wavelength range. Accordingly, a wide range of X-rays can be measured including both long and short wavelengths ranges by utilizing only one counter tube, thus permitting the gases employed to be effectively used.

  20. ICRP 2015. International symposium on the radiation protection system. Report and reflection on a significant symposium

    Lorenz, Bernd

    2016-01-01

    The ICRP international symposium on the radiation protection system provides always extensive information on new developments in radiation protection. The ICRP 2105 discussed the following issues: radiation effects of low dose irradiation, dose coefficients for internal and external exposures, radiation protection in nuclear medicine, application of ICRP recommendations, environmental protection, studies on existing exposure situations, medical radiation protection today, science behind radiation doses, new developments in radiation effects, and ethics in radiation protection.

  1. Operation of radiation monitoring system in radwaste form test facility

    Ryu, Young Gerl; Kim, Ki Hong; Lee, Jae Won; Kwac, Koung Kil

    1998-08-01

    RWFTF (RadWaste Form Test Facility) must have a secure radiation monitoring system (RMS) because of having a hot-cell capable of handling high radioactive materials. And then in controlled radiation zone, which is hot-cell and its maintenance and operation / control room, area dose rate, radioactivities in air-bone particulates and stack, and surface contamination are monitored continuously. For the effective management such as higher utilization, maintenance and repair, the status of this radiation monitoring system, the operation and characteristics of all kinds of detectors and other parts of composing this system, and signal treatment and its evaluation were described in this technical report. And to obtain the accuracy detection results and its higher confidence level, the procedure such as maintenance, functional check and system calibration were established and appended to help the operation of RMS. (author). 6 tabs., 30 figs

  2. A critical review of the system of radiation protection

    2000-01-01

    Our modern, information society is increasingly interested in transparency and participation in many aspects of government, and this is particularly true in areas involving public health and environmental protection. Radiation protection is no exception to this trend. Scientific rationale that was once sufficient to explain radiation protection theory and practice is no longer adequate. The need to address and communicate theory, practice and the decision-making process to a wider audience has given rise to numerous debates and led the radiation protection community to revisit the framework of the system of radiation protection. The very fundamentals of the system of radiation protection continue to be questioned in a healthy fashion, and many aspects have been identified which could better serve stakeholders given some additional thought in the light of modern societal needs. This report is the summary of the NEA's first reflections in this area, and describes those aspects of the current international system of radiation protection that could be improved. Suggested directions for improvement are provided. (author)

  3. Mobile Monitoring System for Nuclear Contamination Analysis

    Broide, A.; Sheinfeld, M.; Marcus, E.; Wengrowicz, U.; Tirosh, D.

    2002-01-01

    In case of a nuclear accident, it is essential to have extensive knowledge concerning the nature of the radioactive plume expansion, for further analysis. For this purpose a mobile monitoring system may provide important data about the plume characteristics. An advanced Mobile Monitoring System is under development at the Nuclear Research Center-Negev. The system is composed of a network of mobile stations, typically installed onboard vehicles, which transmit radiation measurements along with position information to a central station. The mobile network's communications infrastructure is based on Motorola Mobile Logic Unit devices, which are state-of-the-art reliable modems with an integrated Global Positioning System module. The radiation measurements received by the central station are transferred to a risk assessment program, which evaluates the expected hazards to the populated areas located in the estimated plume's expansion direction

  4. The radon daughter radiation hazard in controlled recirculation systems

    Rolle, R.; Burton, R.C.

    1987-01-01

    In deep South African gold mines, controlled recirculation systems with air cooling are being used to an increasing extent to improve the thermal environment. Recirculation causes some air to reside in the working area for a longer time than would have occurred without recirculation. Since radon daughters grow spontaneously from radon there is some concern that, with the extended residence time, the potential radiation hazard could increase to an unacceptable level. This paper describes the results obtained from a theoretical model of a controlled recirculation system. Guidelines for the design of recirculation systems to control the radon daughter radiation, and to keep it within acceptable limits are provided. 3 refs., 5 figs

  5. ACREM: A new air crew radiation exposure measuring system

    Beck, P.; Duftschmid, K.; Kerschbaumer, S.; Schmitzer, C.; Strachotinsky, C.; Grosskopf, A.; Winkler, N.

    1996-01-01

    Cosmic radiation has already been discovered in 1912 by the Austrian Nobel Laureate Victor F. Hess. After Hess up to now numerous measurements of the radiation exposure by cosmic rays in different altitudes have been performed, however, this has not been taken serious in view of radiation protection.Today, with the fast development of modern airplanes, an ever increasing number of civil aircraft is flying in increasing altitudes for considerable time. Members of civil aircrew spending up to 1000 hours per year in cruising altitudes and therefore are subject to significant levels of radiation exposure. In 1990 ICRP published its report ICRP 60 with updated excess cancer risk estimates, which led to significantly higher risk coefficients for some radiation qualities. An increase of the radiation weighting factors for mean energy neutron radiation increases the contribution for the neutron component to the equivalent dose by about 60%, as compared to the earlier values of ICRP26. This higher risk coefficients lead to the recommendation of the ICRP, that cosmic radiation exposure in civil aviation should be taken into account as occupational exposure. Numerous recent exposure measurements at civil airliners in Germany, Sweden, USA, and Russia show exposure levels in the range of 3-10 mSv/year. This is significantly more than the average annual dose of radiation workers (in Austria about 1.5 mSv/year). Up to now no practicable and economic radiation monitoring system for routine application on board exits. A fairly simple and economic approach to a practical, active in-flight dosimeter for the assessment of individual crew exposure is discussed in this paper

  6. Central Nervous System Disease, Education, and Race Impact Radiation Refusal in Pediatric Cancer Patients.

    Patel, Chirayu G; Stavas, Mark; Perkins, Stephanie; Shinohara, Eric T

    2017-07-01

    To investigate the determinants of radiation therapy refusal in pediatric cancer, we used the Surveillance, Epidemiology, and End Results registry to identify 24,421 patients who met the eligibility criteria, diagnosed between 1974 and 2012. Patients had any stage of cancer, were aged 0 to 19, and received radiation therapy or refused radiation therapy when it was recommended. One hundred twenty-eight patients (0.52%) refused radiation therapy when it was recommended. Thirty-two percent of patients who refused radiation therapy ultimately died from their cancer, at a median of 7 months after diagnosis (95% confidence interval, 3-11 mo), as compared with 29.0% of patients who did not refuse radiation therapy died from their cancer, at a median of 17 months after diagnosis (95% confidence interval, 17-18 mo). On multivariable analysis, central nervous system (CNS) site, education, and race were associated with radiation refusal. The odds ratio for radiation refusal for patients with CNS disease was 1.62 (P=0.009) as compared with patients without CNS disease. For patients living in a county with ≥10% residents having less than ninth grade education, the odds ratio for radiation refusal was 1.71 (P=0.008) as compared with patients living in a county with education. Asian, Pacific Islander, Alaska Native, and American Indian races had an odds ratio of 2.12 (P=0.002) for radiation refusal as compared with black or white race. Although the radiation refusal rate in the pediatric cancer population is low, we show that CNS site, education level, and race are associated with a significant difference in radiation refusal.

  7. Radiation Damage Observations in the ATLAS Pixel Detector Using the High Voltage Delivery System

    Toms, K

    2011-01-01

    We describe the implementation of radiation damage monitoring using leakage current measurement of the silicon pixel sensors provided by the circuits of the ATLAS Pixel Detector high voltage delivery (HVPP4) system. The dependence of the leakage current upon the integrated luminosity for several temperature scenarios is presented. Based on the analysis we have determined the sensitivity specifications for a Current Measurement System. The status of the system and the first measurement of the radiation damage corresponding to 2--4 fb$^{-1}$ of integrated luminosity are presented, as well as the comparison with the theoretical model.

  8. Complex systems of biological interest stability under ionising radiations

    Maclot, Sylvain

    2014-01-01

    This PhD work presents the study of stability of molecular systems of biological interest in the gas phase after interaction with ionising radiations. The use of ionising radiation can probe the physical chemistry of complex systems at the molecular scale and thus consider their intrinsic properties. Beyond the fundamental aspect, this work is part of the overall understanding of radiation effects on living organisms and in particular the use of ionizing radiation in radiotherapy. Specifically, this study focused on the use of low-energy multiply charged ions (tens of keV) provided by the GANIL (Caen), which includes most of the experiments presented. In addition, experiments using VUV photons were also conducted at synchrotron ELETTRA (Trieste, Italy). The bio-molecular systems studied are amino acids and nucleic acid constituents. Using an experimental crossed beams device allows interaction between biomolecules and ionising radiation leads mainly to the ionization and fragmentation of the system. The study of its relaxation dynamics is by time-of-flight mass spectrometry coupled to a coincidences measurements method. It is shown that an approach combining experiment and theory allows a detailed study of the fragmentation dynamics of complex systems. The results indicate that fragmentation is generally governed by the Coulomb repulsion but the intramolecular rearrangements involve specific relaxation mechanisms. (author) [fr

  9. Design and Fabrication of Radiation Shielded Micro X-Ray Diffraction System

    Park, Yang Soon; Han, Sun Ho; Ha, Kyeong Yeong; Jee, Kwang Yong

    2006-12-01

    It has been observed that microstructure changes occur at the radial edge of pellet(rim) of the fuel at a high burn-up and extended fuel cycle. The thickness of a rim is some hundreds of micrometers. Despite its narrow range, a rim would affect the behaviour of nuclear fuel. To determine lattice parameter with micro-XRD at intervals as small as 30 - 50 μm in radial direction of irradiated fuel samples, a radiation shielded micro-XRD system was designed and fabricated. This report describes the concept, shielding analysis, the structural design and the fabrication of a radiation shielded glove box for micro-XRD system. This radiation shielded micro-XRD system will be used for analysis of lattice parameter change and the phase distribution at intervals as small as 30 - 50 μm in radial direction of the rim of an irradiated fuel sample and a fuel cladding

  10. Design and Fabrication of Radiation Shielded Micro X-Ray Diffraction System

    Park, Yang Soon; Han, Sun Ho; Ha, Kyeong Yeong; Jee, Kwang Yong

    2006-12-15

    It has been observed that microstructure changes occur at the radial edge of pellet(rim) of the fuel at a high burn-up and extended fuel cycle. The thickness of a rim is some hundreds of micrometers. Despite its narrow range, a rim would affect the behaviour of nuclear fuel. To determine lattice parameter with micro-XRD at intervals as small as 30 - 50 {mu}m in radial direction of irradiated fuel samples, a radiation shielded micro-XRD system was designed and fabricated. This report describes the concept, shielding analysis, the structural design and the fabrication of a radiation shielded glove box for micro-XRD system. This radiation shielded micro-XRD system will be used for analysis of lattice parameter change and the phase distribution at intervals as small as 30 - 50 {mu}m in radial direction of the rim of an irradiated fuel sample and a fuel cladding.

  11. A nuclear radiation multi-parameter measurement system based on pulse-shape sampling

    Qiu Xiaolin; Fang Guoming; Xu Peng; Di Yuming

    2007-01-01

    In this paper, A nuclear radiation multi-parameter measurement system based on pulse-shape sampling is introduced, including the system's characteristics, composition, operating principle, experiment data and analysis. Compared with conventional nuclear measuring apparatus, it has some remarkable advantages such as the synchronous detection using multi-parameter measurement in the same measurement platform and the general analysis of signal data by user-defined program. (authors)

  12. Study concerning an integrated radiation monitoring systems for nuclear facilities

    Oprea, I.; Oprea, M.; Stoica, M.; Cerga, V.; Pirvu, V; Badea, E.

    1996-01-01

    This paper presents an integrated radiation monitoring system designed to assess the effects of nuclear accidents and to provide a basis for making right decisions and countermeasures in order to reduce health damages. The system implies a number of stationary monitoring equipment, data processing unit and a communication network. The system meets the demands of efficiency and reliability, providing the needed tools to easily create programs able to process simple input data filling the information management system. (author). 10 refs

  13. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Vedelago, J. [Laboratorio de Investigaciones e Instrumentacion en Fisica Aplicada a la Medicina e Imagenes por Rayos X, Laboratorio 448 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina); Mattea, F. [Universidad Nacional de Cordoba, Facultad de Ciencias Quimicas, Departamento de Quimica Organica, Ciudad Universitaria, 5000 Cordoba (Argentina); Valente, M., E-mail: josevedelago@gmail.com [Instituto de Fisica E. Gaviola, Oficina 102 FaMAF - UNC, Ciudad Universitaria, 5000 Cordoba (Argentina)

    2014-08-15

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  14. Development a high-resolution radiation dosimetry system based on Fricke solutions

    Vedelago, J.; Mattea, F.; Valente, M.

    2014-08-01

    Due to the growing complexity of modern medical procedures involving the use of ionizing radiation, dosimetry by non-conventional techniques is one of the research areas in the field of greatest interest nowadays. Tissue-equivalent high-resolution dosimetry systems capable of attaining continuous dose mapping are required. In this scenario, Fricke gel dosimetry is a very promising option for in-phantom dose measurements in complex radiation techniques. Implementation of this technique requires dedicated instruments capable of measuring and performing the immediate in situ analysis of the acquired data at the radiation facility. The versatility of Fricke gel dosimetry in different applications depending on the chemical and isotopic composition of the dosimeter extends its application to different high performance conventional and non-conventional radiation procedures involving diverse types of radiation treatments and also radiation diagnosis procedures. This work presents an integral dosimetry system, based on Fricke gel solutions and their analysis by optical techniques, aiming for an increase in the precision on dose determinations. The chemical synthesis and dosimeter preparation were accomplished at LIIFAMIRx facilities, following the procedures and protocols described in previous works. Additionally, specific instrumentation for optical sample analysis was completely designed and constructed at LIIFAMIRx facilities. The main outcome of this work was the development of a methodology that improves the integral dose determination performance by the pre-irradiation of Fricke gel dosimeters. (author)

  15. An architectural analysis of the elongation of field-grown sunflower root systems. Elements for modelling the effects of temperature and intercepted radiation

    Aguirrezabal, L.A.N.; Tardieu, F.

    1996-01-01

    The effects of photosynthetic photon flux density (PPFD) and soil temperature on root system elongation rate have been analysed by using an architectural framework. Root elongation rate was analysed by considering three terms, (i) the branch appearance rate, (ii) the individual elongation rates of the taproot and branches and (iii) the proportion of branches which stop elongating. Large ranges of PPFD and soil temperature were obtained in a series of field and growth chamber experiments. In the field, the growth of root systems experiencing day-to-day natural fluctuation of PPFD and temperature was followed, and some of the plants under study were shaded. In the growth chamber, plants experienced contrasting and constant PPFDs and root temperatures. The direct effect of apex temperature on individual root elongation rate was surprisingly low in the range 13–25°C, except for the first days after germination. Root elongation rate was essentially related to intercepted PPFD and to distance to the source, both in the field and in the growth chamber. Branch appearance rate substantially varied among days and environmental conditions. It was essentially linked to taproot elongation rate, as the profile of branch density along the taproot was quite stable. The length of the taproot segment carrying newly appeared branches on a given day was equal to taproot elongation on this day, plus a 'buffering term' which transiently increased if taproot elongation rate slowed down. The proportion of branches which stopped elongating a short distance from the taproot ranged from 50–80% and was, therefore, a major architectural variable, although it is not taken into account in current architectural models. A set of equations accounting for the variabilities in elongation rate, branch appearance rate and proportion of branches which stop elongating, as a function of intercepted PPFD and apex temperature is proposed. These equations apply for both field and growth

  16. Application of synchrotron radiation to elemental analysis

    Jones, K.W.; Gordon, B.M.; Hanson, A.L.; Hastings, J.B.; Howells, M.R.; Kraner, H.W.; Chen, J.R.

    1983-01-01

    The use of a synchrotron storage ring as a high brightness source for production of monoergic, variable energy, and highly polarized x-ray beams promises to revolutionize the field of elemental analysis. The results of exploratory work using the Cornell synchrotron facility, CHESS, will be described. Design considerations and features of the new X-Ray Microprobe Facility now under construction at the Brookhaven National Synchrotron Light Source will be presented. This facility will be used for bulk analysis and for microanalysis with an initial spatial resolution of the order of 30 μm

  17. Significance of grafting in radiation curing reactions. Comparison of ionising radiation and UV systems

    Zilic, E.; Ng, L.; Viengkhou, V.; Garnett, J.L.

    1998-01-01

    Full text: Radiation curing is now an accepted commercial technology where both ionising radiation (electron beam) and ultra violet light (UV) sources are used. Grafting is essentially the copolymerisation of a monomer/oligomer to a backbone polymer whereas curing is the rapid polymerisation of a monomer/oligomer mixture onto the surface of the substrate. There is no time scale theoretically associated with grafting processes which can occur in minutes or hours whereas curing reactions are usually very rapid, occurring within a fraction of a second. An important difference between grafting and curing is the nature of the bonding occurring in each process. In grafting covalent carbon-carbon bonds are formed, whereas in curing, bonding usually involves weaker Van der Waals or London dispersion forces. The bonding properties of the systems are important in determining their use commercially. Thus the possibility that concurrent grafting during curing could occur in a system is important since if present, grafting would not only minimise delamination of the coated product but could also, in some circumstances, render difficulties recycling of the finished product especially if it were cellulosic. Hence the conditions for observing the occurrence of concurrent grafting during radiation curing are important. In the present paper, this problem has been studied by examining the effect that the components used in radiation curing exert on a typical reaction. Instead of electron beam sources, the spent fuel element facility at Lucas Heights is used to simulate such ionising radiation sources. The model system utilised is the grafting of a typical methacrylate to cellulose. This is the generic chemistry used in curing systems. The effect of typical additives from curing systems including polyfunctional monomer and oligomers in the grafting reactions have been studied. The ionising radiation results have been compared with analogous data from UV experiments. The significance

  18. Patient QA systems for rotational radiation therapy

    Fredh, Anna; Scherman, J.B.; Munck af Rosenschöld, Per Martin

    2013-01-01

    The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors.......The purpose of the present study was to investigate the ability of commercial patient quality assurance (QA) systems to detect linear accelerator-related errors....

  19. Radiation formation of colloidal metallic particles in aqueous systems

    Cuba, Vaclav; Nemec, Mojmir; Gbur, Tomas; John, Jan; Pospisil, Milan; Mucka, Viliam

    2008-01-01

    Full text: Radiation and photochemical methods have been successfully utilized in various steps of nanoparticles preparation. Presented study deals with formation of silver nanoparticles in various aqueous solutions initiated by UV and gamma radiation. Silver nitrate and silver cyanide were used as precursors for radiation and/or photochemical reduction of Ag + ions to the metallic form. Influence of various parameters (dose of radiation, dose rate, exposition time) on nucleation and formation of colloid particles was studied. Attention was also focused on composition of irradiated solution. Aliphatic alcohols were used as scavengers of OH radicals and other oxidizing species. Various organic stabilizers of formed nanoparticles were used, among others ethylenediaminetetraacetic acid, citric acid and polyvinyl alcohol. Irradiation effects were evaluated using UV/Vis absorption spectra in colloid solution, solid phase formed after long-term irradiation was analysed via X-ray structural analysis

  20. Capture and analysis of radiation dose reports for radiology

    Midgley, S.M.

    2014-01-01

    Radiographic imaging systems can produce records of exposure and dose parameters for each patient. A variety of file formats are in use including plain text, bit map images showing pictures of written text and radiation dose structured reports as text or extended markup language files. Whilst some of this information is available with image data on the hospital picture archive and communication system, access is restricted to individual patient records, thereby making it difficult to locate multiple records for the same scan protocol. This study considers the exposure records and dose reports from four modalities. Exposure records for mammography and general radiography are utilized for repeat analysis. Dose reports for fluoroscopy and computed tomography (CT) are utilized to study the distribution of patient doses for each protocol. Results for dosimetric quantities measured by General Radiography, Fluoroscopy and CT equipment are summarised and presented in the Appendix. Projection imaging uses the dose (in air) area product and derived quantities including the dose to the reference point as a measure of the air kerma reaching the skin, ignoring movement of the beam for fluoroscopy. CT uses the dose indices CTDIvol and dose length product as a measure of the dose per axial slice, and to the scanned volume. Suitable conversion factors are identified and used to estimate the effective dose to an average size patient (for CT and fluoroscopy) and the entrance skin dose for fluoroscopy.

  1. The calibration procedure of the radiation monitoring system installed in radiation controlled area of KOMAC

    Park, Sung-Kyun; Min, Yi-Sub; Park, Jeong-Min; Cho, Yong-Sub [Korea Atomic Energy Research Institute, Gyeongju (Korea, Republic of)

    2016-10-15

    The spaces, where these accelerators are installed, are defined as the radiation controlled area and the levels of the radiation in this area are monitored by the radiation monitoring system (RMS) to protect radiation workers and experiment users from the hazards of the ionizing radiation and the surface and air contamination tests are carried out periodically by the radiation secure team. The most of RMS instruments are installed in the accelerator building, where the 100-MeV proton linear accelerator is installed. All detectors of RMS should be calibrated every year to prove the reliability of RMS and almost all instruments for RMS was calibrated during this summer maintenance period of KOMAC this year. Almost all RMS instruments installed in KOMAC is calibrated between 2016-07-13 and 2016-08-24. As the calibration result, if the current reading value are within the 5% of the reference dose rate value, this RMS instrument can be used one more year. Otherwise, the detector of that RMS instrument should be repaired or replaced. The self-calibration certificate for each RMS instrument will be published only for the instrument to satisfy the condition.

  2. GSM module for wireless radiation monitoring system via SMS

    Rahman, Nur Aira Abd; Hisyam Ibrahim, Noor; Lombigit, Lojius; Azman, Azraf; Jaafar, Zainudin; Arymaswati Abdullah, Nor; Hadzir Patai Mohamad, Glam

    2018-01-01

    A customised Global System for Mobile communication (GSM) module is designed for wireless radiation monitoring through Short Messaging Service (SMS). This module is able to receive serial data from radiation monitoring devices such as survey meter or area monitor and transmit the data as text SMS to a host server. It provides two-way communication for data transmission, status query, and configuration setup. The module hardware consists of GSM module, voltage level shifter, SIM circuit and Atmega328P microcontroller. Microcontroller provides control for sending, receiving and AT command processing to GSM module. The firmware is responsible to handle task related to communication between device and host server. It process all incoming SMS, extract, and store new configuration from Host, transmits alert/notification SMS when the radiation data reach/exceed threshold value, and transmits SMS data at every fixed interval according to configuration. Integration of this module with radiation survey/monitoring device will create mobile and wireless radiation monitoring system with prompt emergency alert at high-level radiation.

  3. Request for Travel Funds for Systems Radiation Biology Workshop

    Barcellos-Hoff, Mary Helen [NYU School of Medicine

    2014-03-22

    The 3rd International Systems Radiation Biology Workshop brought together the major European, US and Japanese research programs on radiation risk as well as selected experts representing systems biological approaches to discuss how the new methodologies could be best exploited for low dose research. A significant part of the workshop was devoted to discussions organised as breakout group sessions. To facilitate discussions number of participants was limited to 60 persons. To achieve the goals of this symposium in this international conference, support from DOE is vital. Hence, this proposal requested support in the amount of $15,000 to cover the travel expenses of international experts and radiation biology scientists from the United States. This supporting mechanism was clearly identified to the selected US participants as a conference support award from the DOE (See attached PDF). The workshop was an outstanding opportunity to strengthen interactions between leading experts in the emerging areas of radiation sciences, and will also provide opportunities for younger scientists to meet with experts and discuss their results. This workshop was designed to endorse active engagement in international collaboration. A major objective of this conference was to effectively communicate research results, in order to ensure that current thinking reflects sound science of radiation biology. Further, this international event addressed the use and success of scientific initiatives in radiation biology for policymakers, standard-setters, and the general public.

  4. A radiation-tolerant electronic readout system for portal imaging

    Östling, J.; Brahme, A.; Danielsson, M.; Iacobaeus, C.; Peskov, V.

    2004-06-01

    A new electronic portal imaging device, EPID, is under development at the Karolinska Institutet and the Royal Institute of Technology. Due to considerable demands on radiation tolerance in the radiotherapy environment, a dedicated electronic readout system has been designed. The most interesting aspect of the readout system is that it allows to read out ˜1000 pixels in parallel, with all electronics placed outside the radiation beam—making the detector more radiation resistant. In this work we are presenting the function of a small prototype (6×100 pixels) of the electronic readout board that has been tested. Tests were made with continuous X-rays (10-60 keV) and with α particles. The results show that, without using an optimised gas mixture and with an early prototype only, the electronic readout system still works very well.

  5. Europe's contribution to implementation of a radiation protection system

    Lecomte, J.F.

    2010-01-01

    What is commonly referred to as a radiation protection system is a range of scientific considerations, principles and rules, the aim of which is to contribute to an appropriate level of protection of individuals and the environment against the harmful effects of exposure to ionising radiation, without excessively limiting desirable human activities which can be associated with such exposure (see ICRP Publication 103). This system is essentially based on an international consensus. The European level only concerns the Member States of the Union but it is crucial that it constitute the final, legally binding step prior to the definition of national regulations. The European radiation protection system (the EURATOM Treaty and its derived legislation) is presented below, not from the legal perspective but from a contextual viewpoint. Research activities are not discussed here. (author)

  6. Radiation protection: an analysis of thyroid blocking

    Aldrich, D.C.; Blond, R.M.

    1980-01-01

    An analysis was performed to provide guidance to policymakers concerning the effectiveness of potassium iodide (KI) as a thyroid blocking agent in potential reactor accident situations, the distance to which (or area within which) it should be distributed, and its relative effectiveness compared to other available protective measures. The analysis was performed using the Reactor Safety Study (WASH-1400) consequence model. Four categories of accidents were addressed: gap activity release accident (GAP), GAP without containment isolation, core melt with a melt-through release, and core melt with an atmospheric release. Cost-benefit ratios (US $/thyroid nodule prevented) are given assuming that no other protective measures are taken. Uncertainties due to health effects parameters, accident probabilities, and costs are assessed. The effects of other potential protective measures, such as evacuation and sheltering, and the impact on children (critical population) are evaluated. Finally, risk-benefit considerations are briefly discussed

  7. Radiation management of retinoblastoma; An analysis

    Takemasa, Kazuhiko; Ito, Hisao; Hashimoto, Shozo; Tanaka, Yasuhiko; Oguchi, Yoshihisa (Keio Univ., Tokyo (Japan). School of Medicine)

    1991-12-01

    An analysis has been conducted of 45 patients treated for retinoblastoma at Keio University Hospital between 1970 and 1990. Of these patients, 32 had unilateral lesion and 13 had bilateral lesion. Further, since their disease was far advanced, 29 patients with unilateral lesion and 12 patients with bilateral lesion underwent enucleation. As a result, 3 patients with unilateral retinoblastoma and all patients with bilateral manifestation of the disease were treated with radiotherapy (45-50 Gy) with or without cryotherapy and photocoagulation. One patient with unilateral lesion, who had received both radiotherapy and chemotherapy, showed metastases at the first presentation at our clinic and thus was excluded from this analysis. Among 16 eyes of 15 patients who were given radiotherapy, 6 eyes developed recurrence and needed to have further treatment. In 6 eyes out of 12, cataract developed, and out of 10 eyes in which eye function was evaluable, good vision was able to be preserved in 5 eyes. (author).

  8. Current state and trend of radiation regulation system in Japan

    Yonehara, Hidenori

    2004-01-01

    Japanese regulation system for safety against radiation essentially started from 'Atomic Energy Basic Law' enacted in 1955 and 'Law Concerning Prevention of Radiation Hazards due to Radioisotopes, etc' enacted in 1957, has been regarded as a central rule for radiation protection and safety. Related laws and regulations have been enacted together with their revision. Radiation Council, established in the Science and Technology Agency in 1962 and now belonging to the Ministry of Education, Culture, Sports, Science and Technology, has deliberated basically on International Commission of Radiological Protection (ICRP) statements for legal revision and has set up working groups for current problems. Activities of the groups have concerned ICRP Publication 60 (1990) and later related publications for incorporating the principle into laws as to concepts of dose limits, effective dose, and then of exemption and exclusion. International status of the Japanese regulation, problems and tasks in the regulation are also commented. (N.I.)

  9. Dosimetric methodology and reference system for diagnostic level X radiation

    Potiens, Maria da Penha Albuquerque

    1999-01-01

    Several methodologies for the calibration of diagnostic radiology instruments were developed and established at the Calibration Laboratory of IPEN. These established radiation qualities are recommended by international standards. The methods may be used in the calibration procedures of survey meters used in radiation protection measurements (scattered radiation), instruments used in direct beams (attenuated and non attenuated beams) and quality control instruments. A reference system was proposed using two identical ionization chambers developed at IPEN. They differ only by the collecting electrode material, one of aluminium and the other of graphite. The different energetic dependence of the chamber's response provided a ratio related to the tube potential. The variation of only 0.28%, from 14.3 to 111 keV, on the energetic dependence of the graphite electrode chamber, provided the possibility of air kerma rate determination in the studied radiation beams. (author)

  10. AN IMAGE-ANALYSIS TECHNIQUE FOR DETECTION OF RADIATION-INDUCED DNA FRAGMENTATION AFTER CHEF ELECTROPHORESIS

    ROSEMANN, M; KANON, B; KONINGS, AWT; KAMPINGA, HH

    CHEF-electrophoresis was used as a technique to detect radiation-induced DNA breakage with special emphasis to biological relevant X-ray doses (0-10 Gy). Fluorescence detection of DNA-fragments using a sensitive image analysis system was directly compared with conventional scintillation counting of

  11. 1 D analysis of Radiative Shock damping by lateral radiative losses

    Busquet, Michel; Audit, Edouard

    2008-11-01

    We have demonstrated the effect of the lateral radiative losses in radiative shocks propagative in layered quasi-planar atmospheres.[1,2] The damping of the precursor is sensitive to the fraction of self-emitted radiation reflected by the walls (called albedo) We have given recently an experimental determination of the wall albedo.[2] For parametric analysis of this effect, we implement lateral losses in the 1D hydro-rad code MULTI [3] and compared results with 2D simulations. [1] S.Leygnac, et al., Phys. Plasmas 13, 113301 (2006) [2] M.Busquet, et al, High Energy Density Plasmas 3, 8-11 (2007); M.Gonzalez, et al, Laser Part. Beams 24, 1-6 (2006) [3] Ramis et al, Comp. Phys. Comm., 49, 475 (1988)

  12. Medicine and ionizing radiation: help cards for risk analysis

    Gauron, C.

    2004-01-01

    Following an inquiry in Ile de France on radiation protection, a scientific committee associating several institutions and different experts has elaborated cards for help to risk analysis. A first series of this cards is published in this issue documents for the labour physician and will be next on Internet. the other fields of medical use will be covered in the future. (N.C.)

  13. Radiation-hardened microwave communications system

    Smith, S. F.; Bible, D. W.; Crutcher, R. I.; Hannah, J. H.; Moore, J. A.; Nowlin, C. H.; Vandermolen, R. I.; Chagnot, D.; Leroy, A.

    1993-03-01

    To develop a wireless communication system to meet the stringent requirements for a nuclear hot cell and similar environments, including control of advanced servomanipulators, a microwave signal transmission system development program was established to produce a demonstration prototype for the Consolidated Fuel Reprocessing Program at Oak Ridge National Laboratory (ORNL). Proof-of-principle tests in a partially metal lined enclosure at ORNL successfully demonstrated the feasibility of directed microwave signal transmission techniques for remote systems applications. The potential for much more severe radio-frequency (RF) multipath propagation conditions in fully metal lined cells led to a programmatic decision to conduct additional testing in more typical hot-cell environments at other sites. Again, the test results were excellent. Based on the designs of the earlier systems, an advanced microwave signal transmission system configuration was subsequently developed that, in highly reflective environments, will support both high-performance video channels and high baud-rate digital data links at total gamma dose tolerance levels exceeding 10(exp 7) rads and at elevated ambient temperatures.

  14. Radiation-hardened microwave communications system

    Smith, S.F.; Bible, D.W.; Crutcher, R.I.; Hannah, J.H.; Moore, J.A.; Nowlin, C.H.; Vandermolen, R.I.; Chagnot, D.; LeRoy, A.

    1993-01-01

    To develop a wireless communication system to meet the stringent requirements for a nuclear hot cell and similar environments, including control of advanced servomanipulators, a microwave signal transmission system development program was established to produce a demonstration prototype for the Consolidated Fuel Reprocessing Program at Oak Ridge National Laboratory (ORNL). Proof-of-principle tests in a partially metal lined enclosure at ORNL successfully demonstrated the feasibility of directed microwave signal transmission techniques for remote systems applications. The potential for much more severe radio-frequency (RF) multipath propagation conditions in fully metal lined cells led to a programmatic decision to conduct additional testing in more typical hot-cell environments at other sites. Again, the test results were excellent. Based on the designs of the earlier systems, an advanced microwave signal transmission system configuration was subsequently developed that, in highly reflective environments, will support both high-performance video channels and high baud-rate digital data links at total gamma dose tolerance levels exceeding 10 7 rads and at elevated ambient temperatures

  15. Effect of ionizing radiation on moist air systems

    Reed, D.T.; Van Konynenburg, R.A.

    1987-01-01

    The radiation chemistry of nitrogen/oxygen/water systems is reviewed. General radiolytic effects in dry nitrogen/oxygen systems are relatively well characterized. Irradiation results in the formation of steady state concentrations of ozone, nitrous oxide and nitrogen dioxide. In closed systems, the concentration observed depends on the total dose, temperature and initial gas composition. Only three studies have been published that focus on the radiation chemistry of nitrogen/oxygen/water homogeneous gas systems. Mixed phase work that is relevant to the gaseous system is also summarized. The presence of water vapor results in the formation of nitric acid and significantly changes the chemistry observed in dry air systems. Mechanistic evidence from the studies reviewed are summarized and discussed in relation to characterizing the gas phase during the containment period of a repository in tuff

  16. External radiation exposure control system in accelerator facilities

    Ogawa, Tatsuhiko; Iimoto, Takeshi; Kosako, Toshiso

    2011-01-01

    The external exposure control systems in KEK and CERN are discussed to find out good practices and unreasonableness of radiation control in accelerator facilities, which plays an important role in optimizing national and/or site specific radiological regulations, referring to relevant ICRP publications. Personal dose limits and radiation area classifications were analyzed and their reasonableness were explored. Good example of supervised areas, area classification based on realistic assumptions on working time etc are found. On the other hand, unreasonable systems, that are often attributed to the national regulation or ideas presented in the old publications are also found. (author)

  17. Photo and radiation chemistry of polymeric systems and nanomaterials

    Mikhaylov, A.I.

    2004-01-01

    New approaches of analytical ESR-spectroscopy to studying of free-radical and electron-transport processes at radiation-chemical and photochemical modification both fictionalization of polymeric systems and nanomaterials were surveyed. Measuring techniques using of ESR-spectroscopy of paramagnetic centers were fulfilled. The radiation-chemical processes of modification, microencapsulation and kinetic stabilization of thermodynamically incompatible systems and interfaces for nanomaterials including fullerenes, nanotubes, nanofibres, etc. and composites on the basis of synthetic and natural polymers including plant fibers, fluoropolymers, polyolefins, etc. were developed

  18. Radiation monitoring systems: current status and future prospects

    McArthur, W.C.; Kniazewycz, B.G.

    1978-01-01

    The Radiation Monitoring System (RMS) in a nuclear power plant is used for assessing radiological impact of plant operation. A classical RMS consists of several types of radiation detectors strategically placed about a nuclear plant to ensure the safety of operating personnel and the surrounding environment. It serves in conjunction with, and as a backup to, a comprehensive sampling program to quantitatively evaluate process systems and effluent activity levels. The development of the computerized and digitalized RMS is reviewed with emphasis upon its added capability and flexibility. The potential future requirements for the RMS, as a result of regulatory criteria development, is briefly discussed

  19. Flexible Receiver Radiation Detection System (FRRDS) Users Manual

    Troyer, G.L.

    1996-01-01

    The Flexible Receiver Radiation Detection System (FRRDS) comprises a control computer, a remote data acquisition subsystem, and three hyperpure germanium gamma radiation detectors. The scope of this document is the description of various steps for the orderly start-up, use, and shutdown of the FRRDS. Only those items necessary for these oprations are included. This document is a companion to WHC-SD-W151-UM-002, 'Operating Instructions for the 42 Inch Flexible Receiver,' WHC-SD-W151-UM-003, 'Operating Instructions for the 4-6 Inch Flexible Receiver,' and the vendor supplied system users guide (Ref. 6)

  20. The Advanced Light Source (ALS) Radiation Safety System

    Ritchie, A.; Oldfather, D.; Lindner, A.

    1993-05-01

    The Advanced Light Source (ALS) at the Lawrence Berkeley Laboratory (LBL) is a 1.5 GeV synchrotron light source facility consisting of a 120 keV electron gun, 50 MeV linear accelerator, 1.5 Gev booster synchrotron, 200 meter circumference electron storage ring, and many photon beamline transport systems for research. The Radiation Safety System for the ALS has been designed and built with a primary goal of providing protection against inadvertent personnel exposure to gamma and neutron radiation and, secondarily, to enhance the electrical safety of select magnet power supplies

  1. A mathematical model of radiation effect on the immunity system

    Smirnova, O.A.

    1984-01-01

    A mathematical model, simulating the effect of ionizing radiation on the dynamics of humoral immune reaction is suggested. It represents the system of nonlinear differential equations and is realized in the form of program in Fortran computer language. The model describes the primary immune reaction of nonirradiated organism on T-independent antigen, reflects the postradiation lymphopoiesis dynamics in nonimmunized mammals, simulates the processes of injury and recovery of the humoral immunity system under the combined effect of ionizing radiation and antigenic stimulation. The model can be used for forecasting imminity state in irradiated mammals

  2. Radiation

    2013-01-01

    The chapter one presents the composition of matter and atomic theory; matter structure; transitions; origin of radiation; radioactivity; nuclear radiation; interactions in decay processes; radiation produced by the interaction of radiation with matter

  3. Analysis of integrated video and radiation data

    Howell, J.A.; Menlove, H.O.; Rodriguez, C.A.; Beddingfield, D.; Vasil, A.

    1995-01-01

    We have developed prototype software for a facility-monitoring application that will detect anomalous activity in a nuclear facility. The software, which forms the basis of a simple model, automatically reviews and analyzes integrated safeguards data from continuous unattended monitoring systems. This technology, based on pattern recognition by neural networks, provides significant capability to analyze complex data and has the ability to learn and adapt to changing situations. It is well suited for large automated facilities, reactors, spent-fuel storage facilities, reprocessing plants, and nuclear material storage vaults

  4. Radiation safety management system in a radioactive facility

    Amador, Zayda H.

    2008-01-01

    Full text: This paper illustrates the Cuban experience in implementing and promoting an effective radiation safety system for the Centre of Isotopes, the biggest radioactive facility of our country. Current management practice demands that an organization inculcate culture of safety in preventing radiation hazard. The aforementioned objectives of radiation protection can only be met when it is implemented and evaluated continuously. Commitment from the workforce to treat safety as a priority and the ability to turn a requirement into a practical language is also important to implement radiation safety policy efficiently. Maintaining and improving safety culture is a continuous process. There is a need to establish a program to measure, review and audit health and safety performance against predetermined standards. All those areas of the radiation protection program are considered (e.g. licensing and training of the staff, occupational exposure, authorization of the practices, control of the radioactive material, radiological occurrences, monitoring equipment, radioactive waste management, public exposure due to airborne effluents, audits and safety costs). A set of indicators designed to monitor key aspects of operational safety performance are used. Their trends over a period of time are analyzed with the modern information technologies, because this can provide an early warning to plant management for searching causes behind the observed changes. In addition to analyze the changes and trends, these indicators are compared against identified targets and goals to evaluate performance strengths and weaknesses. A structured and proper radiation self-auditing system is seen as a basic requirement to meet the current and future needs in sustainability of radiation safety. The integrated safety management system establishment has been identified as a goal and way for the continuous improvement. (author)

  5. Radiation warning system in Slovenia (ROSS)

    Arh, S.

    1996-01-01

    Recognizing that a radiological accident may have a widespread effect, the Slovenian government has decided to establish an early warning system. The aim of it is to detect any incident (domestic or foreign) involving radioactivity as fast as possible, to initiate appropriate measures, and to give immediate warning to the population

  6. Evolution of the radiation protection system; L'evolution du systeme de protection radiologique

    Clarke, R.H. [International Commission on Radiological Protection, Stockholm (Sweden); Schieber, C.; Cordoliani, Y.S. [Societe Francaise de Radioprotection, 92 - Fontenay aux Roses (France); Brechignac, F. [CEA Cadarache, Institut de Radioprotection et de Surete Nucleaire, Dept. de Protection de l' Environnement, 13 - Saint Paul Lez Durance (France)

    2003-07-01

    The evolution of the system of radiological protection: justification for new ICRP recommendations, thoughts of the SFRP work group about the evolution of the system of radiation protection proposed by the ICRP, protection of environment against ionizing radiations seen by the ICRP are the three parts of this chapter. (N.C.)

  7. Real-time information and processing system for radiation protection

    Oprea, I.; Oprea, M.; Stoica, M.; Badea, E.; Guta, V.

    1999-01-01

    The real-time information and processing system has as main task to record, collect, process and transmit the radiation level and weather data, being proposed for radiation protection, environmental monitoring around nuclear facilities and for civil defence. Such a system can offer information in order to provide mapping, data base, modelling and communication and to assess the consequences of nuclear accidents. The system incorporates a number of stationary or mobile radiation monitoring equipment, weather parameter measuring station, a GIS-based information processing center and the communication network, all running on a real-time operating system. It provides the automatic data collection on-line and off-line, remote diagnostic, advanced presentation techniques, including a graphically oriented executive support, which has the ability to respond to an emergency by geographical representation of the hazard zones on the map.The system can be integrated into national or international environmental monitoring systems, being based on local intelligent measuring and transmission units, simultaneous processing and data presentation using a real-time operating system for PC and geographical information system (GIS). Such an integrated system is composed of independent applications operating under the same computer, which is capable to improve the protection of the population and decision makers efforts, updating the remote GIS data base. All information can be managed directly from the map by multilevel data retrieving and presentation by using on-line dynamic evolution of the events, environment information, evacuation optimization, image and voice processing

  8. Logical analysis of biological systems

    Mardare, Radu Iulian

    2005-01-01

    R. Mardare, Logical analysis of biological systems. Fundamenta Informaticae, N 64:271-285, 2005.......R. Mardare, Logical analysis of biological systems. Fundamenta Informaticae, N 64:271-285, 2005....

  9. An evaluation system for electronic retrospective analyses in radiation oncology: implemented exemplarily for pancreatic cancer

    Kessel, Kerstin A.; Jäger, Andreas; Bohn, Christian; Habermehl, Daniel; Zhang, Lanlan; Engelmann, Uwe; Bougatf, Nina; Bendl, Rolf; Debus, Jürgen; Combs, Stephanie E.

    2013-03-01

    To date, conducting retrospective clinical analyses is rather difficult and time consuming. Especially in radiation oncology, handling voluminous datasets from various information systems and different documentation styles efficiently is crucial for patient care and research. With the example of patients with pancreatic cancer treated with radio-chemotherapy, we performed a therapy evaluation by using analysis tools connected with a documentation system. A total number of 783 patients have been documented into a professional, web-based documentation system. Information about radiation therapy, diagnostic images and dose distributions have been imported. For patients with disease progression after neoadjuvant chemoradiation, we designed and established an analysis workflow. After automatic registration of the radiation plans with the follow-up images, the recurrence volumes are segmented manually. Based on these volumes the DVH (dose-volume histogram) statistic is calculated, followed by the determination of the dose applied to the region of recurrence. All results are stored in the database and included in statistical calculations. The main goal of using an automatic evaluation system is to reduce time and effort conducting clinical analyses, especially with large patient groups. We showed a first approach and use of some existing tools, however manual interaction is still necessary. Further steps need to be taken to enhance automation. Already, it has become apparent that the benefits of digital data management and analysis lie in the central storage of data and reusability of the results. Therefore, we intend to adapt the evaluation system to other types of tumors in radiation oncology.

  10. Neutron radiative capture methods for surface elemental analysis

    Trombka, J.I.; Senftle, F.; Schmadebeck, R.

    1970-01-01

    Both an accelerator and a 252Cf neutron source have been used to induce characteristic gamma radiation from extended soil samples. To demonstrate the method, measurements of the neutron-induced radiative capture and activation gamma rays have been made with both Ge(Li) and NaI(Tl) detectors, Because of the possible application to space flight geochemical analysis, it is believed that NaI(Tl) detectors must be used. Analytical procedures have been developed to obtain both qualitative and semiquantitative results from an interpretation of the measured NaI(Tl) pulse-height spectrum. Experiment results and the analytic procedure are presented. ?? 1970.

  11. Numerical model of solar dynamic radiator for parametric analysis

    Rhatigan, Jennifer L.

    1989-01-01

    Growth power requirements for Space Station Freedom will be met through addition of 25 kW solar dynamic (SD) power modules. Extensive thermal and power cycle modeling capabilities have been developed which are powerful tools in Station design and analysis, but which prove cumbersome and costly for simple component preliminary design studies. In order to aid in refining the SD radiator to the mature design stage, a simple and flexible numerical model was developed. The model simulates heat transfer and fluid flow performance of the radiator and calculates area mass and impact survivability for many combinations of flow tube and panel configurations, fluid and material properties, and environmental and cycle variations.

  12. Tricho system: hypertrichosis, radiation, and cancer

    Lapidus, S.M.

    1976-01-01

    Five women in their 6th to 8th decades were treated for facial hypertrichosis in Erie, Pennsylvania, 30 to 40 years ago. The epilations were performed with an x-ray device called Tricho System, which was manufactured, sold, and proclaimed safe by its physician-inventor. The beauty shop operator who administered these treatments may or may not have received instruction by the company in the operation of the equipment. At varying intervals, each of the 5 women developed radiodermatitis and basal cell and/or squamous cell carcinoma at the sites of epilation. All presented to the plastic surgical service at the Hamot Medical Center in Erie, Pennsylvania. Two underwent massive radical resective surgery, 2 required extensive excision and resurfacing, and 1 refused resective surgery althouth she had had a previous surgical attempt 17 years earlier. Case histories are presented in detail. This series is representative of the epidemic nature of Tricho-System-induced disease

  13. Radiation monitoring system in medical facilities

    Matsuno, Kiyoshi

    1981-01-01

    (1) RI selective liquid effluent monitor is, in many cases, used at medical facilities to obtain data for density of radioactivity of six radionuclides. In comparison with the conventional gross measuring systems, over-evaluation is less, and the monitor is more practical. (2) Preventive monitor for loss of radium needle is a system which prevents missing of radium needle at a flush-toilet in radium treatment wards, and this monitor is capable of sensing a drop-off of radium needle of 0.5 mCi (minimum). (3) Short-lived positron gas measuring device belongs to a BABY CYCLOTRON installed in a hospital, and this device is used to measure density of radioactivity, radioactive impurity and chemical impurity of produced radioactive gas. (author)

  14. Radiative heat transfer in low-dimensional systems -- microscopic mode

    Woods, Lilia; Phan, Anh; Drosdoff, David

    2013-03-01

    Radiative heat transfer between objects can increase dramatically at sub-wavelength scales. Exploring ways to modulate such transport between nano-systems is a key issue from fundamental and applied points of view. We advance the theoretical understanding of radiative heat transfer between nano-objects by introducing a microscopic model, which takes into account the individual atoms and their atomic polarizabilities. This approach is especially useful to investigate nano-objects with various geometries and give a detailed description of the heat transfer distribution. We employ this model to study the heat exchange in graphene nanoribbon/substrate systems. Our results for the distance separations, substrates, and presence of extended or localized defects enable making predictions for tailoring the radiative heat transfer at the nanoscale. Financial support from the Department of Energy under Contract No. DE-FG02-06ER46297 is acknowledged.

  15. Calibration method of radiation monitoring system at TQNPC

    Liu Zhengshan; Zhang Qingli; Liu Jinjin; Miao Yuxing; Geng Lixin; Zhuang Yun; Dong Jianfeng; He Change

    2009-04-01

    The calibration methods and calibration device for standard monitor of radioactive particulate, iodine, noble gas and so on are not yet set up at home. On consideration of the present situation of the radiation monitoring system at the Third Qinshan Nuclear Power Co. Ltd., we have studied the calibration method of these radiation monitoring instruments used for measuring the waste liquid, particulate, iodine and noble gas produced during the operation of nuclear reactor. Through the check against these instruments during the No. 202 and No. 103 overhaul, we got initially the method of the calibration and obtained the transfer coefficient of calibration when secondary solid sources are used for calibration. Through the testing and calibration, the credibility of the radiation monitoring system is enhanced. And at the same time, the problems existing in the calibration are discussed. (authors)

  16. A national computerized system for monitoring operational radiation exposure

    Canipelle, A.D.

    1996-01-01

    In parallel to the expansion of the number of French nuclear power plant units in operation, maintenance actions have multiplied, which has meant calling upon the services of a growing number of increasingly specialized workers. It has therefore proved necessary to reinforce the radiation dose rate surveillance of these workers. As a result, certain companies decided to set up their own occupational radiation dose monitoring system, in addition to mandatory monitoring by the OPRI, using dosemeters, generally electronic or thermoluminescent film badges, supplied by the subcontractor companies or nuclear facility operators. This enables acquiring fast and accurate knowledge of the radiation doses received by the workers. For this type of surveillance to be fully efficient, a data centralization system was required, able to provide frequent, even daily readings if necessary, of the dose received during the current month or for any period of time, up to the sum of the doses accumulated over five years. (author)

  17. High speed infrared radiation thermometer, system, and method

    Markham, James R.

    2002-01-01

    The high-speed radiation thermometer has an infrared measurement wavelength band that is matched to the infrared wavelength band of near-blackbody emittance of ceramic components and ceramic thermal barrier coatings used in turbine engines. It is comprised of a long wavelength infrared detector, a signal amplifier, an analog-to-digital converter, an optical system to collect radiation from the target, an optical filter, and an integral reference signal to maintain a calibrated response. A megahertz range electronic data acquisition system is connected to the radiation detector to operate on raw data obtained. Because the thermometer operates optimally at 8 to 12 .mu.m, where emittance is near-blackbody for ceramics, interferences to measurements performed in turbine engines are minimized. The method and apparatus are optimized to enable mapping of surface temperatures on fast moving ceramic elements, and the thermometer can provide microsecond response, with inherent self-diagnostic and calibration-correction features.

  18. Multiple Antenna Systems with Inherently Decoupled Radiators

    Pelosi, Mauro; Knudsen, Mikael B.; Pedersen, Gert Frølund

    2012-01-01

    In multiple antenna systems mutual coupling needs to be minimized. We propose an alternative novel decoupling technique, investigating several multiple antenna configurations for small handsets through measurements and numerical simulations. The influence of different novel designs on performance...... metrics such as total loss, antenna isolation and envelope correlation coefficient are investigated. By varying antenna impedance bandwidth and antenna location with respect to the handset, both Planar Inverted F Antenna (PIFA) and Inverted F Antennas (IFA) were investigated in different UMTS frequency...

  19. Realistic modeling of radiation transmission inspection systems

    Sale, K.E.

    1993-01-01

    We have applied Monte Carlo particle transport methods to assess a proposed neutron transmission inspection system for checked luggage. The geometry of the system and the time, energy and angle dependence of the source have been modeled in detail. A pulsed deuteron beam incident on a thick Be target generates a neutron pulse with a very broad energy spectrum which is detected after passage through the luggage item by a plastic scintillator detector operating in current mode (as opposed to pulse counting mode). The neutron transmission as a function of time information is used to infer the densities of hydrogen, carbon, oxygen and nitrogen in the volume sampled. The measured elemental densities can be compared to signatures for explosives or other contraband. By using such computational modeling it is possible to optimize many aspects of the design of an inspection system without costly and time consuming prototyping experiments or to determine that a proposed scheme will not work. The methods applied here can be used to evaluate neutron or photon schemes based on transmission, scattering or reaction techniques

  20. Corrosion potential analysis system

    Kiefer, Karl F.

    1998-03-01

    Many cities in the northeastern U.S. transport electrical power from place to place via underground cables, which utilize voltages from 68 kv to 348 kv. These cables are placed in seamless steel pipe to protect the conductors. These buried pipe-type-cables (PTCs) are carefully designed and constantly pressurized with transformer oil to prevent any possible contamination. A protective coating placed on the outside diameter of the pipe during manufacture protects the steel pipe from the soil environment. Notwithstanding the protection mechanisms available, the pipes remain vulnerable to electrochemical corrosion processes. If undetected, corrosion can cause the pipes to leak transformer oil into the environment. These leaks can assume serious proportions due to the constant pressure on the inside of the pipe. A need exists for a detection system that can dynamically monitor the corrosive potential on the length of the pipe and dynamically adjust cathodic protection to counter local and global changes in the cathodic environment surrounding the pipes. The northeastern United States contains approximately 1000 miles of this pipe. This milage is critical to the transportation and distribution of power. So critical, that each of the pipe runs has a redundant double running parallel to it. Invocon, Inc. proposed and tested a technically unique and cost effective solution to detect critical corrosion potential and to communicate that information to a central data collection and analysis location. Invocon's solution utilizes the steel of the casing pipe as a communication medium. Each data gathering station on the pipe can act as a relay for information gathered elsewhere on the pipe. These stations must have 'smart' network configuration algorithms that constantly test various communication paths and determine the best and most power efficient route through which information should flow. Each network station also performs data acquisition and analysis tasks that ultimately

  1. The computer code system for reactor radiation shielding in design of nuclear power plant

    Li Chunhuai; Fu Shouxin; Liu Guilian

    1995-01-01

    The computer code system used in reactor radiation shielding design of nuclear power plant includes the source term codes, discrete ordinate transport codes, Monte Carlo and Albedo Monte Carlo codes, kernel integration codes, optimization code, temperature field code, skyshine code, coupling calculation codes and some processing codes for data libraries. This computer code system has more satisfactory variety of codes and complete sets of data library. It is widely used in reactor radiation shielding design and safety analysis of nuclear power plant and other nuclear facilities

  2. Use of Existing CAD Models for Radiation Shielding Analysis

    Lee, K. T.; Barzilla, J. E.; Wilson, P.; Davis, A.; Zachman, J.

    2015-01-01

    The utility of a radiation exposure analysis depends not only on the accuracy of the underlying particle transport code, but also on the accuracy of the geometric representations of both the vehicle used as radiation shielding mass and the phantom representation of the human form. The current NASA/Space Radiation Analysis Group (SRAG) process to determine crew radiation exposure in a vehicle design incorporates both output from an analytic High Z and Energy Particle Transport (HZETRN) code and the properties (i.e., material thicknesses) of a previously processed drawing. This geometry pre-process can be time-consuming, and the results are less accurate than those determined using a Monte Carlo-based particle transport code. The current work aims to improve this process. Although several Monte Carlo programs (FLUKA, Geant4) are readily available, most use an internal geometry engine. The lack of an interface with the standard CAD formats used by the vehicle designers limits the ability of the user to communicate complex geometries. Translation of native CAD drawings into a format readable by these transport programs is time consuming and prone to error. The Direct Accelerated Geometry -United (DAGU) project is intended to provide an interface between the native vehicle or phantom CAD geometry and multiple particle transport codes to minimize problem setup, computing time and analysis error.

  3. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (DEC VAX VERSION WITH NASADIG)

    Anderson, G. E.

    1994-01-01

    The Thermal Radiation Analyzer System, TRASYS, is a computer software system with generalized capability to solve the radiation related aspects of thermal analysis problems. TRASYS computes the total thermal radiation environment for a spacecraft in orbit. The software calculates internode radiation interchange data as well as incident and absorbed heat rate data originating from environmental radiant heat sources. TRASYS provides data of both types in a format directly usable by such thermal analyzer programs as SINDA/FLUINT (available from COSMIC, program number MSC-21528). One primary feature of TRASYS is that it allows users to write their own driver programs to organize and direct the preprocessor and processor library routines in solving specific thermal radiation problems. The preprocessor first reads and converts the user's geometry input data into the form used by the processor library routines. Then, the preprocessor accepts the user's driving logic, written in the TRASYS modified FORTRAN language. In many cases, the user has a choice of routines to solve a given problem. Users may also provide their own routines where desirable. In particular, the user may write output routines to provide for an interface between TRASYS and any thermal analyzer program using the R-C network concept. Input to the TRASYS program consists of Options and Edit data, Model data, and Logic Flow and Operations data. Options and Edit data provide for basic program control and user edit capability. The Model data describe the problem in terms of geometry and other properties. This information includes surface geometry data, documentation data, nodal data, block coordinate system data, form factor data, and flux data. Logic Flow and Operations data house the user's driver logic, including the sequence of subroutine calls and the subroutine library. Output from TRASYS consists of two basic types of data: internode radiation interchange data, and incident and absorbed heat rate data

  4. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (DEC VAX VERSION WITHOUT NASADIG)

    Vogt, R. A.

    1994-01-01

    The Thermal Radiation Analyzer System, TRASYS, is a computer software system with generalized capability to solve the radiation related aspects of thermal analysis problems. TRASYS computes the total thermal radiation environment for a spacecraft in orbit. The software calculates internode radiation interchange data as well as incident and absorbed heat rate data originating from environmental radiant heat sources. TRASYS provides data of both types in a format directly usable by such thermal analyzer programs as SINDA/FLUINT (available from COSMIC, program number MSC-21528). One primary feature of TRASYS is that it allows users to write their own driver programs to organize and direct the preprocessor and processor library routines in solving specific thermal radiation problems. The preprocessor first reads and converts the user's geometry input data into the form used by the processor library routines. Then, the preprocessor accepts the user's driving logic, written in the TRASYS modified FORTRAN language. In many cases, the user has a choice of routines to solve a given problem. Users may also provide their own routines where desirable. In particular, the user may write output routines to provide for an interface between TRASYS and any thermal analyzer program using the R-C network concept. Input to the TRASYS program consists of Options and Edit data, Model data, and Logic Flow and Operations data. Options and Edit data provide for basic program control and user edit capability. The Model data describe the problem in terms of geometry and other properties. This information includes surface geometry data, documentation data, nodal data, block coordinate system data, form factor data, and flux data. Logic Flow and Operations data house the user's driver logic, including the sequence of subroutine calls and the subroutine library. Output from TRASYS consists of two basic types of data: internode radiation interchange data, and incident and absorbed heat rate data

  5. TRASYS - THERMAL RADIATION ANALYZER SYSTEM (CRAY VERSION WITH NASADIG)

    Anderson, G. E.

    1994-01-01

    The Thermal Radiation Analyzer System, TRASYS, is a computer software system with generalized capability to solve the radiation related aspects of thermal analysis problems. TRASYS computes the total thermal radiation environment for a spacecraft in orbit. The software calculates internode radiation interchange data as well as incident and absorbed heat rate data originating from environmental radiant heat sources. TRASYS provides data of both types in a format directly usable by such thermal analyzer programs as SINDA/FLUINT (available from COSMIC, program number MSC-21528). One primary feature of TRASYS is that it allows users to write their own driver programs to organize and direct the preprocessor and processor library routines in solving specific thermal radiation problems. The preprocessor first reads and converts the user's geometry input data into the form used by the processor library routines. Then, the preprocessor accepts the user's driving logic, written in the TRASYS modified FORTRAN language. In many cases, the user has a choice of routines to solve a given problem. Users may also provide their own routines where desirable. In particular, the user may write output routines to provide for an interface between TRASYS and any thermal analyzer program using the R-C network concept. Input to the TRASYS program consists of Options and Edit data, Model data, and Logic Flow and Operations data. Options and Edit data provide for basic program control and user edit capability. The Model data describe the problem in terms of geometry and other properties. This information includes surface geometry data, documentation data, nodal data, block coordinate system data, form factor data, and flux data. Logic Flow and Operations data house the user's driver logic, including the sequence of subroutine calls and the subroutine library. Output from TRASYS consists of two basic types of data: internode radiation interchange data, and incident and absorbed heat rate data

  6. Development of aerial gamma radiation survey system III

    Nagaoka, Toshi; Sakamoto, Ryuichi; Saito, Kimiaki; Tsutsumi, Masahiro; Moriuchi, Shigeru; Miyasaka, Satoshi.

    1985-01-01

    An aerial gamma-ray survey system using a helicopter has been developed since 1980 in order to perform quick gamma-ray survey covering a wide area. To form a line in the chain of the development, a series of flight measurements were conducted in Watarase reservoir, Tochigi prefecture, in which artificial gamma-ray fields were realized using 60 Co (100 and 400 mCi) and 137 Cs (100 and 300 mCi) point sources located on the ground. For the purpose of obtaining gamma-ray pulse height spectra in the field, 6 sets of NaI(Tl) scientillation detectors were prepared. These sets of detectors consist of ones for evaluation with high accuracy as the standard, for intercomparison with other authors' results, and for practical use. Two sets of them were boarded for each flight considering the exposure rate level and detector's sensitivity. The flight measurements were performed in a space of 20 m to 500 m in altitude, and 0 m to 500 m in horizontal distance from the source. The experimental results of the spatial gamma-ray distribution for each gamma-ray field satisfactorily agreed with calculational results by Monte Carlo method. Throughout this experiment, characteristics of this survey system and detectors were clarified, and versatile data processing and analysis code was completed. Also, a method for subtraction of background exposure rate in a field including artificial radiation component was discussed using energy band information, and the coefficients for this method were determined. These data obtained are expected to be used as widely applicable data not only for the interpretation of measured value, but also for analysis of environmental gamma-ray field. (author)

  7. Bond strength of dental adhesive systems irradiated with ionizing radiation.

    Dibo da Cruz, Adriana; Goncalves, Luciano de Souza; Rastelli, Alessandra Nara de Souza; Correr-Sobrinho, Lorenco; Bagnato, Vanderlei Salvador; Boscolo, Frab Norberto

    2010-04-01

    The aim of the present paper was to determine the effect of different types of ionizing radiation on the bond strength of three different dentin adhesive systems. One hundred twenty specimens of 60 human teeth (protocol number: 032/2007) sectioned mesiodistally were divided into 3 groups according to the adhesives systems used: SB (Adper Single Bond Plus), CB (Clearfil SE Bond) and AP (Adper Prompt Self-Etch). The adhesives were applied on dentin and photo-activated using LED (Lec 1000, MMoptics, 1000 mW/cm2). Customized elastomer molds (0.5 mm thickness) with three orifices of 1.2 mm diameter were placed onto the bonding areas and filled with composite resin (Filtek Z-250), which was photo-activated for 20 s. Each group was subdivided into 4 subgroups for application of the different types of ionizing radiation: ultraviolet radiation (UV), diagnostic x-ray radiation (DX), therapeutic x-ray radiation (TX) and without irradiation (control group, CG). Microshear tests were carried out (Instron, model 4411), and afterwards the modes of failure were evaluated by optical and scanning electron microscope and classified using 5 scores: adhesive failure, mixed failures with 3 significance levels, and cohesive failure. The results of the shear bond strength test were submitted to ANOVA with Tukey's test and Dunnett's test, and the data from the failure pattern evaluation were analyzed with the Mann Whitney test (p = 0.05). No change in bond strength of CB and AP was observed after application of the different radiation types, only SB showed increase in bond strength after UV (p = 0.0267) irradiation. The UV also changed the failure patterns of SB (p = 0.0001). The radio-induced changes did not cause degradation of the restorations, which means that they can be exposed to these types of ionizing radiation without weakening the bond strength.

  8. RAMOS - the radiation monitoring system of the Umweltforschungsinstitut Global 2000

    Exler, M.; Schmittner, W.

    2001-01-01

    The radiation early warning system RAMOS (radiation monitoring system) measures the radioactivity of the areas surrounding nuclear technical facilities (at present, around the Nuclear Power Plants Dukovany and Mochovce). Measurements are taken with Gamma-radiation devices of the type RS 03/X by the firm BITT- Technology. These devices are measuring equipment of the type Proportion-count tube with a detection range of 10 nSv/h to 10 Sv/h. The measuring stations consist of this Gamma measuring equipment, a personal computer with modem, back-up electricity devices and meteorological measuring devices. Six such measuring stations surrounding the facility comprise a complete measuring ring. The values are measured each minute. Considering the normal fluctuation in radiation measurements due to geology and weather conditions and the average background radiation, a certain alarm threshold is defined (on all stations this threshold is under 230 nSv/h). If this threshold is breached, immediately the data is transmitted through telephone lines and is received by the central office. Because of the short reaction time and low threshold, valuable time is gained for an emergency response by government agencies and the population. Official warning of the government agencies occurs after fulfilling the commendation of the Austrian Radiation Protection Commission. In the continued measurements from the end of 1994 to 2000 at NPP Dukovany and continuous measurements from NPP Mochovce from mid-1999 to the end of 2000, there was not a detection of dangerous levels of radiation were released into the atmosphere. After close examination of the measured data, different types of fluctuations could be observed - such as during the day-time period and short-term peaks after rain-fall. Detailed knowledge about trends in these fluctuations, allows an easier continual evaluation of a potential accident. The measured data is given to the public in graphic form every month via the Internet

  9. Radiation leakage monitoring method and device from primary to secondary coolant systems in nuclear reactor

    Tajiri, Yoshiaki; Umehara, Toshihiro; Yamada, Masataka.

    1993-01-01

    The present invention monitors radiation leaked from any one of primary cooling systems to secondary cooling systems in a plurality of steam generators. That is, radiation monitoring means each corresponding to steam each generators are disposed to the upstream of a position where main steam pipes are joined. With such a constitution, since the detection object of each of radiation monitoring means is secondary coolants before mixing with secondary coolants of other secondary loops or dilution, lowering of detection accuracy can be avoided. Except for the abnormal case, that is, a case neither of radiation leakage nor of background change, the device is adapted as a convenient measuring system only with calculation performance. Once abnormality occurs, a loop having a value exceeding a standard value is identified by a single channel analyzer function. The amount of radiation leakage from the steam generator belonging to the specified loop is monitored quantitatively by a multichannel analyzer function. According to the method of the present invention, since specific spectrum analysis is conducted upon occurrence of abnormality, presence of radiation leakage and the scale thereof can be judged rapidly. (I.S.)

  10. Effects of ionizing radiation on the immune system

    Dubois, J.B.

    1986-01-01

    After reviewing the different lymphoid organs and the essential phases of the immune response, we studied the morphological and functional effects of ionizing radiation on the immunological system. Histologic changes in the lymph nodes, spleen, thymus, and different lymphocyte subpopulations were studied in relation with the radiation dose and irradiated volume (whole body irradiation, localized irradiation). Functional changes in the immune system induced by ionizing radiation were also investigated by a study of humoral-mediated immunity (antibody formation) and cell-mediated immunity (behavior of macrophages, B-cells, T suppressor cells, T helper cells, T effector cells, and natural killer cells). A study into the mechanisms of action of ionizing radiation and the immune processes it interferes with suggests several likely hypotheses (direct action on the immune cells, on their precursors, on seric mediators or on cell mediators). The effects on cancer patients' immune reactions of low radiation doses delivered to the various lymphoid organs are discussed, as well as the relationships between the host and the evolution of the tumor [fr

  11. Real Time Environmental Radiation Monitoring System in the Philippines

    Garcia, Teofilo Y.

    2015-01-01

    The widespread release of radioactive materials caused by the Fukushima Daiichi Nuclear Power Plant Accident that occurred on 11 March 2011 raised concerns on the environmental radiation monitoring Presently, the Philippine Nuclear Research Institute (PNRI) can only perform limited incident. Country-wide radiation measurements by carrying out field-works in the different provinces of the country. This is due to limitation in the availability of appropriate equipment to carry-out the task of conducting radiation measurements, especially in remote and hart to access areas of the country. Although no nuclear reactor is currently operating in the Philippines, it is situated in a region surrounded by neighboring countries with several existing or planned nuclear power plants. While nuclear power has tremendous benefits in meeting the electricity needs of growing populations, and does not have the adverse environmental effects associated with burning of fossil fuels, there are potential risks from releases of radio nuclides into the environment. The PNRI, through the support of the International Atomic Energy Agency (IAEA), is establishing an on-line environmental radiation monitoring system that can provide real-time environmental during emergencies that lead to extensive spread of radioactive materials, such as nuclear power plant accidents, an on-line radiation monitoring system will enable the immediate detection of radiological emergencies affecting the country and will provide important information of authorities for appropriate emergency response. (author)

  12. Radiation testing of electronics for the CMS endcap muon system

    Bylsma, B. [Ohio State University (United States); Cady, D.; Celik, A. [Texas A and M University, College Station, TX 77843 (United States); Durkin, L.S. [Ohio State University (United States); Gilmore, J., E-mail: gilmore@tamu.edu [Texas A and M University, College Station, TX 77843 (United States); Haley, J. [Northeastern University (United States); Khotilovich, V.; Lakdawala, S. [Texas A and M University, College Station, TX 77843 (United States); Liu, J.; Matveev, M.; Padley, B.P.; Roberts, J. [Rice University (United States); Roe, J.; Safonov, A.; Suarez, I. [Texas A and M University, College Station, TX 77843 (United States); Wood, D. [Northeastern University (United States); Zawisza, I. [Texas A and M University, College Station, TX 77843 (United States)

    2013-01-11

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  13. Radiation testing of electronics for the CMS endcap muon system

    Bylsma, B.; Cady, D.; Celik, A.; Durkin, L. S.; Gilmore, J.; Haley, J.; Khotilovich, V.; Lakdawala, S.; Liu, J.; Matveev, M.; Padley, B. P.; Roberts, J.; Roe, J.; Safonov, A.; Suarez, I.; Wood, D.; Zawisza, I.

    2013-01-01

    The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the innermost portion of the CMS detector, with 8900 rad over 10 years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

  14. A new radiation safety control system for Ganil

    Saint Jores, P. De; Luong, T.T.; Martina, L.; Vega, G.

    1991-01-01

    A second generation radiation safety control system has been installed to upgrade the initial system which was not flexible enough to support new ion beams and new experimental conditions required by the accelerator operation. The main reasons which necessitated the improvement of the safety control system are presented. The new system which controls the Ganil accelerator from the first quarter of 1990 is described. It uses a star structured architecture, VME standard processors and front-end modules activated by pDOS operating system and high level language (C and Fortran) tasks, associated with enhanced resolution color displays for real time synoptics. (R.P.) 4 refs., 4 figs

  15. The natural horn as an efficient sound radiating system ...

    Results obtained showed that the locally made horn are efficient sound radiating systems and are therefore excellent for sound production in local musical renditions. These findings, in addition to the portability and low cost of the horns qualify them to be highly recommended for use in music making and for other purposes ...

  16. Semiconductor dosimetry system for gamma and neutron radiation

    Savic, Z.; Pavlovic, Z.

    1995-01-01

    The semiconductor dosimetry system for gamma and neutron radiation based on pMOS transistor and PIN diode is described. It is intended for tactical or accidental personal dosimetry. The production steps are given. The temperature, dose and time (fading) response are reported. Hardware and software requirements which are needed for obtaining the desired measurement error are pointed. (author)

  17. Radiating Frohlich system as a model of cellular electromagnetism

    Šrobár, Fedor

    2015-01-01

    Roč. 34, č. 4 (2015), s. 355-360 ISSN 1536-8378 Institutional support: RVO:67985882 Keywords : electromagnetic radiation * Fröhlich systems * cell physiology Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.208, year: 2015

  18. EMERALD-NORMAL, Routine Radiation Release and Dose for PWR Design Analysis and Operation Analysis

    Gillespie, S.G.; Brunot, W.K.

    1976-01-01

    1 - Description of problem or function: EMERALD-NORMAL is designed for the calculation of radiation releases and exposures resulting from normal operation of a large pressurized water reactor. The approach used is similar to an analog simulation of a real system. Each component or volume in the plant which contains a radioactive material is represented by a subroutine which keeps track of the production, transfer, decay, and absorption of radioactivity in that volume. During the course of the analysis, activity is transferred from subroutine to subroutine in the program as it would be transferred from place to place in the plant. Some of this activity is then released to the atmosphere and to the discharge canal. The rates of transfer, leakage, production, cleanup, decay, and release are read as input to the program. Subroutines are also included which calculate the off-site radiation exposures at various distances for individual isotopes and sums of isotopes. The program contains a library of physical data for the forty isotopes of most interest in licensing calculations, and other isotopes can be added or substituted. Because of the flexible nature of the simulation approach, the EMERALD-NORMAL program can be used for most calculations involving the production and release of radioactive material. These include design, operation, and licensing studies. 2 - Method of solution: Explicit solutions of first-order linear differential equations are included. In addition, a subroutine is provided which solves a set of simultaneous linear algebraic equations. 3 - Restrictions on the complexity of the problem: Many parameters and systems included in the program, particularly the radiation waste-treatment system, are unique to the PG and E Diablo Canyon PWR plant. Maxima of: 50 isotopes, 9 distances, 16 angular sectors, 1 operating period, 1 reactor power level

  19. Statistical data processing with automatic system for environmental radiation monitoring

    Zarkh, V.G.; Ostroglyadov, S.V.

    1986-01-01

    Practice of statistical data processing for radiation monitoring is exemplified, and some results obtained are presented. Experience in practical application of mathematical statistics methods for radiation monitoring data processing allowed to develop a concrete algorithm of statistical processing realized in M-6000 minicomputer. The suggested algorithm by its content is divided into 3 parts: parametrical data processing and hypotheses test, pair and multiple correlation analysis. Statistical processing programms are in a dialogue operation. The above algorithm was used to process observed data over radioactive waste disposal control region. Results of surface waters monitoring processing are presented

  20. Radiation internal exposure measurements archiving system (REMAS)

    Bitar, A.; Maghrabi, M.

    2013-01-01

    This paper describes a personal-computer-based software, REMAS, which helps users to estimate intake activity and resulting internal doses for all radionuclides existing in (International Commission on Radiological Protection) ICRP 78 and other important elements. In addition to its use in internal dose calculations, it facilitates management of data of monitored persons who are occupationally exposed to unsealed radioactive substances. Furthermore, REMAS offers the possibility to generate different reports of results. The program is suitable for laboratories working in the field of assessment of occupational intake and also for users of radioactive material who are routinely monitored. REMAS, which is bilingual program (English and Arabic), was built with GUI environment and was developed using Microsoft FoxPro. It runs on Microsoft Windows XP operating systems. (authors)