WorldWideScience

Sample records for radial ulnar angular

  1. Anomalies of radial and ulnar arteries

    Directory of Open Access Journals (Sweden)

    Rajani Singh

    Full Text Available Abstract During dissection conducted in an anatomy department of the right upper limb of the cadaver of a 70-year-old male, both origin and course of the radial and ulnar arteries were found to be anomalous. After descending 5.5 cm from the lower border of the teres major, the brachial artery anomalously bifurcated into a radial artery medially and an ulnar artery laterally. In the arm, the ulnar artery lay lateral to the median nerve. It followed a normal course in the forearm. The radial artery was medial to the median nerve in the arm and then, at the level of the medial epicondyle, it crossed from the medial to the lateral side of the forearm, superficial to the flexor muscles. The course of the radial artery was superficial and tortuous throughout the arm and forearm. The variations of radial and ulnar arteries described above were associated with anomalous formation and course of the median nerve in the arm. Knowledge of neurovascular anomalies are important for vascular surgeons and radiologists.

  2. Ulnar nerve entrapment complicating radial head excision

    Directory of Open Access Journals (Sweden)

    Kevin Parfait Bienvenu Bouhelo-Pam

    Full Text Available Introduction: Several mechanisms are involved in ischemia or mechanical compression of ulnar nerve at the elbow. Presentation of case: We hereby present the case of a road accident victim, who received a radial head excision for an isolated fracture of the radial head and complicated by onset of cubital tunnel syndrome. This outcome could be the consequence of an iatrogenic valgus of the elbow due to excision of the radial head. Hitherto the surgical treatment of choice it is gradually been abandoned due to development of radial head implant arthroplasty. However, this management option is still being performed in some rural centers with low resources. Discussion: The radial head plays an important role in the stability of the elbow and his iatrogenic deformity can be complicated by cubital tunnel syndrome. Conclusion: An ulnar nerve release was performed with favorable outcome. Keywords: Cubital tunnel syndrome, Peripheral nerve palsy, Radial head excision, Elbow valgus

  3. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  4. Radial and ulnar bursae of the wrist: cadaveric investigation of regional anatomy with ultrasonographic-guided tenography and MR imaging

    International Nuclear Information System (INIS)

    Aguiar, R.O.C.; Gasparetto, E.L.; Marchiori, E.; Escuissato, D.L.; Trudell, D.J.; Haghighi, P.; Resnik, D.

    2006-01-01

    To demonstrate the anatomy of the radial and ulnar bursae of the wrist using MR and US images. Ultrasonographic-guided tenography of the tendon sheath of flexor pollicis longus (FPL) and the common tendon sheath of the flexor digitorum of the fifth digit (FD5) of ten cadaveric hands was performed, followed by magnetic resonance imaging and gross anatomic correlation. Patterns of communication were observed between these tendon sheaths and the radial and ulnar bursae of the wrist. The tendon sheath of the FPL communicated with the radial bursa in 100% (10/10) of cases, and the tendon sheath of the FD5 communicated with the ulnar bursa in 80% (8/10). Communication of the radial and ulnar bursae was evident in 100% (10/10), and presented an ''hourglass'' configuration in the longitudinal plane. The ulnar and radial bursae often communicate. The radial bursa communicates with the FPL tendon sheath, and the ulnar bursa may communicate with the FD5 tendon sheath

  5. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  6. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  7. Pseudarthrosis of radial shaft with dislocation of heads of radial and ulnar bones (case report

    Directory of Open Access Journals (Sweden)

    M. E. Puseva

    2013-01-01

    Full Text Available The authors presented a rare clinical case - the injury of forearm complicated by the formation of the pseudarthrosis of the radial shaft in combination with old dislocation of heads the radius and ulna. The differentiated approach to the choice of surgical tactics was proposed, which consists of several consistent stages: taking free autotransplant from the crest of iliac bone, resection of pseudarthrosis of radius with replacement of the bone defect by the graft for restoration of anatomic length, conducting combined strained osteosynthesis and elimination of dislocation of a head of radial and ulnar bones by transosseous osteosynthesis. The chosen treatment strategy allowed to restore the anatomy and function of the upper extremity.

  8. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases.

    Science.gov (United States)

    St-Jean, G; Debowes, R M

    1992-04-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.At the time of injury, the calves ranged in age from one day to two months and weighed from 37-102 kg. Two fractures were comminuted and one was transverse. All fractures were closed. After surgery, all calves could walk within 24 hours. Radiographic and clinical evidence of fracture healing was present five to seven weeks (mean 6) after surgery. At that time, the pins and cast material were removed. Return to normal function was rapid and judged to be excellent at follow-up evaluation five to nine months later.Advantages of transfixation pinning and casting in management of radial-ulnar fractures include flexibility in pin positioning, adequate maintenance of reduction, early return to weight-bearing status, preservation of joint mobility, and ease of ambulation. The inability to adjust fixation and alignment after cast application is a disadvantage of this technique compared with other external fixators. We concluded that transfixation pinning is a useful means of stabilizing radial-ulnar fractures in pediatric bovine patients.

  9. Concepts of radial and angular kinetic energies

    DEFF Research Database (Denmark)

    Dahl, Jens Peder; Schleich, W.P.

    2002-01-01

    We consider a general central-field system in D dimensions and show that the division of the kinetic energy into radial and angular parts proceeds differently in the wave-function picture and the Weyl-Wigner phase-space picture, Thus, the radial and angular kinetic energies are different quantities...

  10. Relationship between the Ulnar Nerve and the Branches of the Radial Nerve to the Medial Head of the Triceps Brachii Muscle.

    Science.gov (United States)

    Sh, Cho; Ih, Chung; Uy, Lee

    2018-05-17

    One branch of the radial nerve to the medial head of the triceps brachii muscle (MHN) has been described as accompanying or joining the ulnar nerve. Mostly two MHN branches have been reported, with some reports of one; however, the topographical anatomy is not well documented. We dissected 52 upper limbs from adult cadavers and found one, two, and three MHN branches in 9.6%, 80.8%, and 9.6% of cases, respectively. The MHN accompanying the ulnar nerve was always the superior MHN. The relationship between the ulnar nerve and the MHN was classified into four types according to whether the MHN was enveloped along with the ulnar nerve in the connective tissue sheath and whether it was in contact with the ulnar nerve. It contacted the ulnar nerve in 75.0% of cases and accompanied it over a mean distance of 73.6 mm (range 36-116 mm). In all cases in which the connective tissue sheath enveloped the branch of the MHN and the ulnar nerve, removing the sheath confirmed that the MHN branch originated from the radial nerve. The detailed findings and anatomical measurements of the MHN in this study will help in identifying its branches during surgical procedures. This article is protected by copyright. All rights reserved. © 2018 Wiley Periodicals, Inc.

  11. Transfixation pinning and casting of radial-ulnar fractures in calves: A review of three cases

    OpenAIRE

    St-Jean, Guy; Debowes, Richard M.

    1992-01-01

    We reviewed the medical records of three calves with radial-ulnar fractures which were reduced and stabilized by transfixation pinning and casting. Multiple Steinmann pins were placed transversely through proximal and distal fracture fragments and the pin ends were incorporated in fiberglass cast material after fracture reduction. Cast material was placed from proximal to distal radius and served as an external frame to maintain pin position and fracture reduction.

  12. High-resolution MRI of the ulnar and radial collateral ligaments of the wrist.

    Science.gov (United States)

    Nozaki, Taiki; Wu, Wei Der; Kaneko, Yasuhito; Rafijah, Gregory; Yang, Lily; Hitt, Dave; Yoshioka, Hiroshi

    2017-12-01

    Background Accurate diagnosis of injuries to the collateral ligaments of the wrist is technically challenging on MRI. Purpose To investigate usefulness of high-resolution two-dimensional (2D) and isotropic three-dimensional (3D) magnetic resonance imaging (MRI) for identifying and classifying the morphology of the ulnar and radial collateral ligaments (UCL and RCL) of the wrist. Material and Methods Thirty-seven participants were evaluated using 3T coronal 2D and isotropic 3D images by two radiologists independently. The UCL was classified into four types: 1a, narrow attachment to the tip of the ulnar styloid (Tip); 1b, broad attachment to the Tip; 2a, narrow attachment to the medial base of the ulnar styloid (Base); and 2b, broad attachment to the Base. The RCL was also classified into four types: 1a, separate radioscaphoid and scaphotrapezial ligaments (RS + ST) with narrow scaphoid attachment; 1b, RS + ST with broad scaphoid attachment; 2a, continuous radio-scapho-trapezial ligaments (RST) with narrow scaphoid attachment; and 2b, RST with broad scaphoid attachment. The inter-observer reliability of these classifications was calculated. Results Type 1a was the most common of both collateral ligaments. Of UCL classifications, 31.4% were revised after additional review of multiplanar reconstruction (MPR) images from isotropic data. The inter-observer reliability of UCL classification was substantial (k = 0.62) without MPR, and almost perfect (k = 0.84) with MPR. The inter-observer reliability of RCL classification was almost perfect (k = 0.89). Anatomic delineation between the two sequences was not statistically different. Conclusion The UCL and RCL were each identified on high-resolution 2D and isotropic 3D MRI equally well. MPR allows accurate identification of the UCL attachment to the ulnar styloid.

  13. Interfascicular suture with nerve autografts for median, ulnar and radial nerve lesions.

    Science.gov (United States)

    Pluchino, F; Luccarelli, G

    1981-05-01

    Interfascicular nerve suture with autografts is the operation of choice for repairing peripheral nerve injuries because it ensures more precise alignment of the fasciculi and so better chances of reinnervation of the sectioned nerve. The procedure as described by Millesi et al has been used at the Istituto Neurologico di Milano in 30 patients with traumatic lesions of the median, ulnar and radial nerves. All have been followed up for 2 to 7 years since operation. The results obtained are compared with those of other series obtained with interfascicular suture and with epineural suture. Microsurgery is essential. The best time to operate is discussed.

  14. The Relative Contribution to Small Finger Abduction of the Ulnar Versus Radial Slip of the EDM: Implications for Tendon Transfers.

    Science.gov (United States)

    Akinleye, Sheriff D; Culbertson, Maya Deza; Cappelleti, Giacomo; Garofolo, Garret; Choueka, Jack

    2017-09-01

    The extensor digiti minimi (EDM) tendon is commonly divided into a radial slip (EDM-R) and an ulnar slip (EDM-U). To our knowledge, the degree to which each EDM slip concomitantly abducts the small finger with active extension has not been formally tested. This study sought to characterize the comparative contributions of finger abduction inherent to each slip of the EDM to observe the sequelae of active small finger extension following transfer of the contralateral slip. Eighteen fresh-frozen cadaveric hands were used in this study. Starting with the hand in resting position, a controlled traction of 10 N was applied to each slip of the EDM tendon. The range of small finger abduction with respect to the fixed ring finger was recorded utilizing infrared reflective markers tracked through the range of motion using a digital video camera. The mean abduction of the small finger when the radial slip of the EDM tendon was tested was 13.33° (95% confidence interval [CI]: 10.10°-16.55°), which was significantly different ( P ≤ .001) than small finger abduction produced by the ulnar slip of the EDM, with a mean of 23.72° (95% CI: 19.40°-28.04°). Given the fact that the ulnar slip of the EDM tendon is shown to be the major contributor of aberrant abduction with active small finger extension, as traction on this slip produces almost twice as much abduction as the radial slip, the EDM-U is the ideal donor graft with respect to tendon transfers of the EDM.

  15. Stellar Angular Momentum Distributions and Preferential Radial Migration

    Science.gov (United States)

    Wyse, Rosemary; Daniel, Kathryne J.

    2018-04-01

    I will present some results from our recent investigations into the efficiency of radial migration in stellar disks of differing angular momentum distributions, within a given adopted 2D spiral disk potential. We apply to our models an analytic criterion that determines whether or not individual stars are in orbits that could lead to radial migration around the corotation resonance. We couch our results in terms of the local stellar velocity dispersion and find that the fraction of stars that could migrate radially decreases as the velocity dispersion increases. I will discuss implications and comparisons with the results of other approaches.

  16. Ulnar Artery Compression: A Feasible and Effective Approach to Prevent the Radial Artery Occlusion after Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Jun Tian

    2015-01-01

    Full Text Available Background: Radial artery (RA occlusion (RAO is not rare in patients undergoing coronary intervention by transradial approach (TRCI. Predictors of and prevention from RAO have not been systematically studied. This study aimed to analyze the risk factors of the weakness of RA pulsation (RAP and its predictive value for RAO after TRCI, and simultaneously to describe a feasible and effective approach to maintain RA patency. Methods: Between June 2006 and March 2010, all patients who underwent TRCI were classified according to the weakness of RAP after removing compression bandage with confirmation by Doppler ultrasound for the first 30 consecutive patients. Among a total of 2658 patients studied, 187 (7% patients having a weaker RAP were prospectively monitored. At 1 h after bandage removal, the ulnar artery in puncture side of all patients was blocked with manual compression to favor brachial and collateral artery blood flow through the RA until a good RAP was restored. The primary analysis was the occurrence of RAO. Results: Doppler ultrasound demonstrated the significant reduction of both systolic velocity (61.24 ± 3.95 cm/s vs. 72.31 ± 3.57 cm/s and diastolic velocity (1.83 ± 0.32 cm/s vs. 17.77 ± 3.97 cm/s in RA at access side as compared to the contralateral RA (all P < 0.001, but these velocities in ipsilateral ulnar artery (81.2 ± 2.16 cm/s and 13.1 ± 2.86 cm/s, respectively increased profoundly. The average time of ulnar artery compression was 4.1 ± 1.2 h (ranged 2.5-6.5 h. There were two patients experienced persistent RAO with a success rate of 98.9% and RAO in 0.075% of patients after ulnar artery compression was applied. The pulsation of the ulnar artery after compression was removed had not been influenced by the compression. Conclusions: After intervention using TRCI approach, the presence of a weaker RAP is an indicator of imminent RAO. The continuing compression of ipsilateral ulnar artery is an effective approach to

  17. Biomechanical properties of orthogonal plate configuration versus parallel plate configuration using the same locking plate system for intra-articular distal humeral fractures under radial or ulnar column axial load.

    Science.gov (United States)

    Kudo, Toshiya; Hara, Akira; Iwase, Hideaki; Ichihara, Satoshi; Nagao, Masashi; Maruyama, Yuichiro; Kaneko, Kazuo

    2016-10-01

    Previous reports have questioned whether an orthogonal or parallel configuration is superior for distal humeral articular fractures. In previous clinical and biomechanical studies, implant failure of the posterolateral plate has been reported with orthogonal configurations; however, the reason for screw loosening in the posterolateral plate is unclear. The purpose of this study was to evaluate biomechanical properties and to clarify the causes of posterolateral plate loosening using a humeral fracture model under axial compression on the radial or ulnar column separately. And we changed only the plate set up: parallel or orthogonal. We used artificial bone to create an Association for the Study of Internal Fixation type 13-C2.3 intra-articular fracture model with a 1-cm supracondylar gap. We used an anatomically-preshaped distal humerus locking compression plate system (Synthes GmbH, Solothurn, Switzerland). Although this is originally an orthogonal plate system, we designed a mediolateral parallel configuration to use the contralateral medial plate instead of the posterolateral plate in the system. We calculated the stiffness of the radial and ulnar columns and anterior movement of the condylar fragment in the lateral view. The parallel configuration was superior to the orthogonal configuration regarding the stiffness of the radial column axial compression. There were significant differences between the two configurations regarding anterior movement of the capitellum during axial loading of the radial column. The posterolateral plate tended to bend anteriorly under axial compression compared with the medial or lateral plate. We believe that in the orthogonal configuration axial compression induced more anterior displacement of the capitellum than the trochlea, which eventually induced secondary fragment or screw dislocation on the posterolateral plate, or nonunion at the supracondylar level. In the parallel configuration, anterior movement of the capitellum or

  18. A New Shape Description Method Using Angular Radial Transform

    Science.gov (United States)

    Lee, Jong-Min; Kim, Whoi-Yul

    Shape is one of the primary low-level image features in content-based image retrieval. In this paper we propose a new shape description method that consists of a rotationally invariant angular radial transform descriptor (IARTD). The IARTD is a feature vector that combines the magnitude and aligned phases of the angular radial transform (ART) coefficients. A phase correction scheme is employed to produce the aligned phase so that the IARTD is invariant to rotation. The distance between two IARTDs is defined by combining differences in the magnitudes and aligned phases. In an experiment using the MPEG-7 shape dataset, the proposed method outperforms existing methods; the average BEP of the proposed method is 57.69%, while the average BEPs of the invariant Zernike moments descriptor and the traditional ART are 41.64% and 36.51%, respectively.

  19. Ulnar Collateral Ligament Injuries of the Thumb

    Science.gov (United States)

    McKeon, Kathleen E.; Gelberman, Richard H.; Calfee, Ryan P.

    2013-01-01

    Background: The clinical diagnosis of thumb ulnar collateral ligament disruption has been based on joint angulation during valgus stress testing. This report describes a definitive method of distinguishing between complete and partial ulnar collateral ligament injuries by quantifying translation of the proximal phalanx on the metacarpal head during valgus stress testing. Methods: Sixty-two cadaveric thumbs underwent standardized valgus stress testing under fluoroscopy with the ulnar collateral ligament intact, following an isolated release of the proper ulnar collateral ligament, and following a combined release of both the proper and the accessory ulnar collateral ligament (complete ulnar collateral ligament release). Following complete ulnar collateral ligament release, the final thirty-seven thumbs were also analyzed after the application of a valgus force sufficient to cause 45° of valgus angulation at the metacarpophalangeal joint to model more severe soft-tissue injury. Two independent reviewers measured coronal plane joint angulation (in degrees), ulnar joint line gap formation (in millimeters), and radial translation of the proximal phalanx on the metacarpal head (in millimeters) on digital fluoroscopic images that had been randomized. Results: Coronal angulation across the stressed metacarpophalangeal joint progressively increased through the stages of the testing protocol: ulnar collateral ligament intact (average [and standard deviation], 20° ± 8.1°), release of the proper ulnar collateral ligament (average, 23° ± 8.3°), and complete ulnar collateral ligament release (average, 30° ± 8.9°) (p collateral ligament release (5.7 ± 1.5 mm), to that following complete ulnar collateral ligament release (7.2 ± 1.5 mm) (p collateral ligament (1.6 ± 0.8 mm vs. 1.5 ± 0.9 mm in the intact state). There was a significant increase in translation following release of the complete ulnar collateral ligament complex (3.0 ± 0.9 mm; p collateral ligament

  20. The superficial ulnar artery: development and clinical significance Artéria ulnar superficial: desenvolvimento e relevância clínica

    Directory of Open Access Journals (Sweden)

    Srinivasulu Reddy

    2007-09-01

    Full Text Available The principal arteries of the upper limb show a wide range of variation that is of considerable interest to orthopedic surgeons, plastic surgeons, radiologists and anatomists. We present here a case of superficial ulnar artery found during the routine dissection of right upper limb of a 50-year-old male cadaver. The superficial ulnar artery originated from the brachial artery, crossed the median nerve anteriorly and ran lateral to this nerve and the brachial artery. The superficial ulnar artery in the arm gave rise to a narrow muscular branch to the biceps brachii. At the elbow level the artery ran superficial to the bicipital aponeurosis where it was crossed by the median cubital vein. It then ran downward and medially superficial to the forearm flexor muscles, and then downward to enter the hand. At the palm, it formed the superficial and deep palmar arches together with the branches of the radial artery. The presence of a superficial ulnar artery is clinically important when raising forearm flaps in reconstructive surgery. The embryology and clinical significance of the variation are discussed.As principais artérias do membro superior apresentam uma ampla variação, que é relativamente importante a cirurgiões ortopédicos e plásticos, radiologistas e anatomistas.Apresentamosumcaso de artéria ulnar superficial encontrada durante dissecção de rotina de membro superior direito de um cadáver masculino de 50 anos de idade.Aartéria ulnar superficial originava-se da artéria braquial, cruzava o nervo mediano anteriormente e percorria lateralmente esse nervo e a artéria braquial. A artéria ulnar superficial no braço deu origem a um ramo muscular estreito do músculo bíceps braquial. Ao nível do cotovelo, a artéria percorria superficialmente a aponeurose bicipital, onde era cruzada pela veia cubital mediana. Percorria, então, em sentido descendente e medialmente superficial aos músculos flexores do antebraço, e então descendia para

  1. Evaluation of the performance of three tenodesis techniques for the treatment of scapholunate instability: flexion-extension and radial-ulnar deviation.

    Science.gov (United States)

    Alonso-Rasgado, Teresa; Zhang, Qing-Hang; Jimenez-Cruz, David; Bailey, Colin; Pinder, Elizabeth; Mandaleson, Avanthi; Talwalkar, Sumedh

    2017-11-25

    Chronic scapholunate ligament (SL) injuries are difficult to treat and can lead to wrist dysfunction. Whilst several tendon reconstruction techniques have been employed in the management of SL instability, SL gap reappearance after surgery has been reported. Using a finite element model and cadaveric study data, we investigated the performance of the Corella, scapholunate axis (SLAM) and modified Brunelli tenodesis (MBT) techniques. Scapholunate dorsal and volar gap and angle were obtained following virtual surgery undertaken using each of the three reconstruction methods with the wrist positioned in flexion, extension, ulnar deviation and radial deviation, in addition to the ulnar-deviated clenched fist and neutral positions. From the study, it was found that, following simulated scapholunate interosseous ligament rupture, the Corella technique was better able to restore the SL gap and angle close to the intact ligament for all wrist positions investigated, followed by SLAM and MBT. The results suggest that for the tendon reconstruction techniques, the use of multiple junction points between scaphoid and lunate may be of benefit. Graphical abstract The use of multiple junction points between scaphoid and lunate may be of benefit for tendon reconstruction techniques.

  2. Ulnar variance: its relationship to ulnar foveal morphology and forearm kinematics.

    Science.gov (United States)

    Kataoka, Toshiyuki; Moritomo, Hisao; Omokawa, Shohei; Iida, Akio; Murase, Tsuyoshi; Sugamoto, Kazuomi

    2012-04-01

    It is unclear how individual differences in the anatomy of the distal ulna affect kinematics and pathology of the distal radioulnar joint. This study evaluated how ulnar variance relates to ulnar foveal morphology and the pronosupination axis of the forearm. We performed 3-dimensional computed tomography studies in vivo on 28 forearms in maximum supination and pronation to determine the anatomical center of the ulnar distal pole and the forearm pronosupination axis. We calculated the forearm pronosupination axis using a markerless bone registration technique, which determined the pronosupination center as the point where the axis emerges on the distal ulnar surface. We measured the depth of the anatomical center and classified it into 2 types: concave, with a depth of 0.8 mm or more, and flat, with a depth less than 0.8 mm. We examined whether ulnar variance correlated with foveal type and the distance between anatomical and pronosupination centers. A total of 18 cases had a concave-type fovea surrounded by the C-shaped articular facet of the distal pole, and 10 had a flat-type fovea with a flat surface without evident central depression. Ulnar variance of the flat type was 3.5 ± 1.2 mm, which was significantly greater than the 1.2 ± 1.1 mm of the concave type. Ulnar variance positively correlated with distance between the anatomical and pronosupination centers. Flat-type ulnar heads have a significantly greater ulnar variance than concave types. The pronosupination axis passes through the ulnar head more medially and farther from the anatomical center with increasing ulnar variance. This study suggests that ulnar variance is related in part to foveal morphology and pronosupination axis. This information provides a starting point for future studies investigating how foveal morphology relates to distal ulnar problems. Copyright © 2012 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Ulnar nerve dysfunction

    Science.gov (United States)

    Neuropathy - ulnar nerve; Ulnar nerve palsy; Mononeuropathy; Cubital tunnel syndrome ... Damage to one nerve group, such as the ulnar nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  4. Motor branches of the ulnar nerve to the forearm: an anatomical study and guidelines for selective neurectomy.

    Science.gov (United States)

    Paulos, Renata; Leclercq, Caroline

    2015-11-01

    Precise knowledge of motor nerve branches is critical to plan selective neurectomies for the treatment of spastic limbs. Our objective is to describe the muscular branching pattern of the ulnar nerve in the forearm and suggest an ideal surgical approach for selective neurectomy of the flexor carpi ulnaris. The ulnar nerve was dissected under loop magnification in 20 upper limbs of fresh frozen cadavers and its branches to the flexor carpi ulnaris muscle (FCU) and to the flexor digitorum profundus muscle (FDP) were quantified. We measured their diameter, length and distance between their origin and the medial epicondyle. The point where the ulnar artery joined the nerve was observed. The position in which the ulnar nerve gave off each branch was noted (ulnar, posterior or radial) and the Martin-Gruber connection, when present, had its origin observed and its diameter measured. The ulnar nerve gave off two to five muscular branches, among which, one to four to the FCU and one or two to the FDP. In all cases, the first branch was to the FCU. It arose on average 1.4 cm distal to the epicondyle, but in four specimens it arose above or at the level of the medial epicondyle (2.0 cm above in one case, 1.5 cm above in two cases, and at the level of the medial epicondyle in one). The first branch to the FDP arose on average 5.0 cm distal to the medial epicondyle. All the branches to FDP but one arose from the radial aspect of the ulnar nerve. A Martin-Gruber connection was present in nine cases. All motor branches arose in the proximal half of the forearm and the ulnar nerve did not give off branches distal to the point where it was joined by the ulnar artery. The number of motor branches of the ulnar nerve to the FCU varies from 2 to 4. An ideal approach for selective neurectomy of the FCU should start 4 cm above the medial epicondyle, and extend distally to 50% of the length of the forearm or just to the point where the ulnar artery joins the nerve.

  5. Constraints on radial migration in spiral galaxies - II. Angular momentum distribution and preferential migration

    Science.gov (United States)

    Daniel, Kathryne J.; Wyse, Rosemary F. G.

    2018-05-01

    The orbital angular momentum of individual stars in galactic discs can be permanently changed through torques from transient spiral patterns. Interactions at the corotation resonance dominate these changes and have the further property of conserving orbital circularity. We derived in an earlier paper an analytic criterion that an unperturbed stellar orbit must satisfy in order for such an interaction to occur, i.e. for it to be in a trapped orbit around corotation. We here use this criterion in an investigation of how the efficiency of induced radial migration for a population of disc stars varies with the angular momentum distribution of that population. We frame our results in terms of the velocity dispersion of the population, this being an easier observable than is the angular momentum distribution. Specifically, we investigate how the fraction of stars in trapped orbits at corotation varies with the velocity dispersion of the population, for a system with an assumed flat rotation curve. Our analytic results agree with the finding from simulations that radial migration is less effective in populations with `hotter' kinematics. We further quantify the dependence of this trapped fraction on the strength of the spiral pattern, finding a higher trapped fraction for higher amplitude perturbations.

  6. Traumatic Distal Ulnar Artery Thrombosis

    Directory of Open Access Journals (Sweden)

    Ahmet A. Karaarslan

    2014-01-01

    Full Text Available This paper is about a posttraumatic distal ulnar artery thrombosis case that has occurred after a single blunt trauma. The ulnar artery thrombosis because of chronic trauma is a frequent condition (hypothenar hammer syndrome but an ulnar artery thrombosis because of a single direct blunt trauma is rare. Our patient who has been affected by a single blunt trauma to his hand and developed ulnar artery thrombosis has been treated by resection of the thrombosed ulnar artery segment. This report shows that a single blunt trauma can cause distal ulnar artery thrombosis in the hand and it can be treated merely by thrombosed segment resection in suitable cases.

  7. Stabilization of the ulnar stump using modified Breen method after the Sauve-Kapandji procedure in rheumatoid wrist

    International Nuclear Information System (INIS)

    Tanino, Yoshihiko; Yabe, Yutaka; Yamauchi, Kenji; Ikegami, Hiroyasu; Ichikawa, Tooru

    2006-01-01

    We report on the utility of the modified Breen method in addition to the Sauve-Kapandji operation for the treatment of instability and pain in the proximal ulnar stump in rheumatoid arthrities (RA) wrist. We treated a total of 15 hands in 12 patients with disturbances due to instability and pain at the proximal ulnar stump. The average follow-up period was 47 months. We evaluated the range of motion, grip strength, radioulnar distance, and the radioulnar distance at the stump using CT during pronation, supination, and neutral positions of the forearm in 11 of the 15 operated hands. We observed that none of the patients showed any signs of pain at the proximal ulnar stump and no scallop sign was observed. In all the cases, the line connecting the center of the radial head to the proximal ulnar stump served as the axis of rotation for the forearm; this was confirmed by the CT images. We concluded that our operative method resulted in stabilization of the proximal ulnar stump and recovery of powerful grip without pain during forearm rotation. (author)

  8. Ulnar artery: The Ulysses ultimate resort for coronary procedures

    Directory of Open Access Journals (Sweden)

    George Hahalis, MD, PhD

    2016-07-01

    Full Text Available Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA. Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates.

  9. Luxation of the elbow complicated by proximal radio-ulnar translocation

    International Nuclear Information System (INIS)

    Ekloef, O.; Nybonde, T.; Karlsson, G.; St. Goeran's Children's Hospital, Stockholm

    1990-01-01

    Luxation of the elbow complicated by proximal radio-ulnar translocation is a rare entity. The clue to diagosis is the reversed position of the bones of the proxomal forearm. In the a.p. projection the radial head articulates with the trochlea and the ulna with the capitellum. This unexpected anatomic relationship is easily overlooked. Delayed reduction may result in permanent impairment of elbow motility. Our experience with three recent cases is presented. (orig.)

  10. Luxation of the elbow complicated by proximal radio-ulnar translocation

    Energy Technology Data Exchange (ETDEWEB)

    Ekloef, O.; Nybonde, T.; Karlsson, G. (St. Goeran' s Children' s Hospital, Stockholm (Sweden). Dept. of Radiology St. Goeran' s Children' s Hospital, Stockholm (Sweden). Dept. of Surgery)

    1990-03-01

    Luxation of the elbow complicated by proximal radio-ulnar translocation is a rare entity. The clue to diagosis is the reversed position of the bones of the proxomal forearm. In the a.p. projection the radial head articulates with the trochlea and the ulna with the capitellum. This unexpected anatomic relationship is easily overlooked. Delayed reduction may result in permanent impairment of elbow motility. Our experience with three recent cases is presented. (orig.).

  11. Anomalous radial and angular strain relaxation around dilute p-, isoelectronic-, and n-type dopants in Si crystal

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Mingshu [School of Physical Sciences, University of Science and Technology of China, Hefei, Anhui Province 230026 (China); Dong, Juncai, E-mail: dongjc@ihep.ac.cn [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China); Chen, Dongliang [Beijing Synchrotron Radiation Facility, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049 (China)

    2017-02-01

    Doping is widely applied in yielding desirable properties and functions in silicon technology; thus, fully understanding the relaxation mechanism for lattice-mismatch strain is of fundamental importance. Here we systematically study the local lattice distortion near dilute IIIA-, IVA-, and VA-group substitutional dopants in Si crystal using density functional theory, and anomalous radial and angular strain relaxation modes are first revealed. Both the nearest-neighbor (NN) bond-distances and the tetrahedral bond-angles are found to exhibit completely opposite dependence on the electronic configurations for the low Z (Z<26) and high Z (Z>26) dopants. More surprisingly, negative and positive angular shifts for the second NN twelve Si2 atoms are unveiled surrounding the p- and n-type dopants, respectively. While electron localization function shows that the doped hole and electron are highly localized near the dopants, hence being responsible for the abnormal angular shifts, a universal radial strain relaxation mechanism dominated by a competition of the Coulomb interactions among the ion-core, bond-charge, and the localized hole or electron is also proposed. These findings may prove to be instrumental in precise design of silicon-based solotronics.

  12. Perforator anatomy of the ulnar forearm fasciocutaneous flap.

    Science.gov (United States)

    Mathy, Jon A; Moaveni, Zachary; Tan, Swee T

    2012-08-01

    The ulnar forearm fasciocutaneous flap (UFFF) is a favourable alternative to the radial forearm flap when thin and pliable tissue is required. The precise anatomy of the cutaneous perforators of UFFF has not been previously reported. The position of cutaneous perforators>0.5 mm was recorded while raising 52 consecutive free UFFFs in 51 patients at our Centre. Three (6%) UFFFs in two patients demonstrated direct cutaneous supply through a superficial ulnar artery, a known anatomic variance. There was no cutaneous perforator>0.5 mm in one flap. Among the remaining 48 dissections, an average of 3 (range, 1-6) cutaneous perforators were identified. Ninety-four percent of these forearms demonstrated at least one perforator>0.5 mm within 3 cm, and all had at least one perforator within 6 cm of the midpoint of the forearm. Proximal perforators were more likely to be musculo-cutaneous through the edge of flexor carpi ulnaris or flexor digitorum superficialis, while mid- to distal perforators were septo-cutaneous. UFFF skin paddle designed to overlie an area within 3 cm of the midpoint between the medial epicondyle and the pisiform is most likely to include at least one cutaneous perforator from the ulnar artery, without a need for intra-operative skin island adjustment. This novel anatomic finding and other practical generalisations are discussed to facilitate successful elevation of UFFF. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  13. Ulnar nerve damage (image)

    Science.gov (United States)

    The ulnar nerve originates from the brachial plexus and travels down arm. The nerve is commonly injured at the elbow because of elbow fracture or dislocation. The ulnar nerve is near the surface of the body where ...

  14. Ulnar artery: The Ulysses ultimate resort for coronary procedures.

    Science.gov (United States)

    Hahalis, George; Deftereos, Spyridon; Bertrand, Olivier F

    2016-08-20

    Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA) only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA). Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO) rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates. Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  15. The natural angle between the hand and handle and the effect of handle orientation on wrist radial/ulnar deviation during maximal push exertions.

    Science.gov (United States)

    Young, Justin G; Lin, Jia-Hua; Chang, Chien-Chi; McGorry, Raymond W

    2013-01-01

    The purpose of this experiment was to quantify the natural angle between the hand and a handle, and to investigate three design factors: handle rotation, handle tilt and between-handle width on the natural angle as well as resultant wrist radial/ulnar deviation ('RUD') for pushing tasks. Photographs taken of the right upper limb of 31 participants (14 women and 17 men) performing maximal seated push exertions on different handles were analysed. Natural hand/handle angle and RUD were assessed. It was found that all of the three design factors significantly affected natural handle angle and wrist RUD, but participant gender did not. The natural angle between the hand and the cylindrical handle was 65 ± 7°. Wrist deviation was reduced for handles that were rotated 0° (horizontal) and at the narrow width (31 cm). Handles that were tilted forward 15° reduced radial deviation consistently (12-13°) across handle conditions. Manual materials handling (MMH) tasks involving pushing have been related to increased risk of musculoskeletal injury. This study shows that handle orientation influences hand and wrist posture during pushing, and suggests that the design of push handles on carts and other MMH aids can be improved by adjusting their orientation to fit the natural interface between the hand and handle.

  16. Rare high origin of the radial artery: a bilateral, symmetrical case ...

    African Journals Online (AJOL)

    Arterial variations in the upper limb can occur at the level of the axillary, brachial, radial and ulnar arteries as well as the palmar arches. This is a report of bilateral, symmetrical high origin of the radial artery from the axillary artery. Knowledge of such variations is important in vascular and reconstructive surgery. (Nig J Surg ...

  17. Clinical effects of internal fixation for ulnar styloid fractures associated with distal radius fractures: A matched case-control study.

    Science.gov (United States)

    Sawada, Hideyoshi; Shinohara, Takaaki; Natsume, Tadahiro; Hirata, Hitoshi

    2016-11-01

    Ulnar styloid fractures are often associated with distal radius fractures. However, controversy exists regarding whether to treat ulnar styloid fractures. This study aimed to evaluate clinical effects of internal fixation for ulnar styloid fractures after distal radius fractures were treated with the volar locking plate system. We used prospectively collected data of distal radius fractures. 111 patients were enrolled in this study. A matched case-control study design was used. We selected patients who underwent fixation for ulnar styloid fractures (case group). Three control patients for each patient of the case group were matched on the basis of age, sex, and fracture type of distal radius fractures from among patients who did not undergo fixation for ulnar styloid fractures (control group). The case group included 16 patients (7 men, 9 women; mean age: 52.6 years; classification of ulnar styloid fractures: center, 3; base, 11; and proximal, 2). The control group included 48 patients (15 men, 33 women; mean age: 61.1 years; classification of ulnar styloid fractures: center, 10; base, 31; and proximal, 7). For radiographic examination, the volar tilt angle, radial inclination angle, and ulnar variance length were measured, and the union of ulnar styloid fractures was judged. For clinical examination, the range of motions, grip strength, Hand20 score, and Numeric Rating Scale score were evaluated. There was little correction loss for each radiological parameter of fracture reduction, and these parameters were not significantly different between the groups. The bone-healing rate of ulnar styloid fractures was significantly higher in the case group than in the control group, but the clinical results were not significantly different. We revealed that there was no need to fix ulnar styloid fractures when distal radius fractures were treated via open reduction and internal fixation with a volar locking plate system. Copyright © 2016 The Japanese Orthopaedic Association

  18. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University, Department of Radiology, School of Medicine (Turkey); Güney, Bünyamin [Muğla Sıtkı Kocman University, Department of Radiology, School of Medicine (Turkey)

    2016-09-15

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  19. A radiographic study of pediatric ulnar anatomy.

    Science.gov (United States)

    Cravino, Mattia; Oni, Julius K; Sala, Debra A; Chu, Alice

    2014-01-01

    The adult ulna has a unique bony architecture that has been described in the literature, but, to the best of our knowledge, the ulnar anatomy in children has not been described. We examined 75 anteroposterior (AP) and 64 lateral radiographs (29 were bilateral) of 50, 0.5- to 11-year-old, healthy children's forearms. On AP radiographs, the total ulnar length, the ulnar proximal angle, the ulnar distal angle, and the distance between each angle from the tip of the triceps insertion; and, on lateral radiographs, the ulnar length and bow deviation were measured. The correlation between age and radiographic measurements, differences based on sex, differences compared with adults' measurements, and interobserver/intraobserver reliability were assessed. Age had a very strong/strong positive correlation with length/distance measurements on both AP and lateral radiographs. Only AP ulnar distal angle was significantly different between sexes (females > males). Compared with the adult ulnar studies, the AP proximal angle in children is significantly smaller and the location of this angle is significantly more distal. Interobserver and intraobserver reliability were very good for length/distance measurements on AP and lateral radiographs. The knowledge of pediatric ulnar anatomy could be helpful in the treatment of forearm deformities due to multiple hereditary exostosis and osteogenesis imperfecta, and in the treatment of ulnar fractures, particularly in Monteggia variants, where restoration of the correct forearm anatomy is essential to obtain good clinical and functional results. Study of diagnostic test, Level II.

  20. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. EL POSIBLE ATRAPAMIENTO DE LA ARTERIA ULNAR POR EL TERCER FASCÍCULO DEL MÚSCULO PRONADOR TERES

    Directory of Open Access Journals (Sweden)

    Satheesha Nayak B

    2012-11-01

    Full Text Available Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea.

  1. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. El posible atrapamiento de la arteria ulnar por el tercer fascículo del músculo pronador teres

    Directory of Open Access Journals (Sweden)

    Naveen Kumar

    2016-03-01

    Full Text Available El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital  pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea. Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.

  2. Numerical Simulation of Radial and Angular Distribution of γ-Ray's Energy Deposition in Scintillation Optical Fibre

    International Nuclear Information System (INIS)

    Tang Shibiao; Yin Zejie; Tang Yu; Huang Huan

    2006-01-01

    Angular and radial distributions of the energy deposition of γ-ray radiation in scintillation optical fibres are simulated and analysed using the Geant4 system. The results show a linear relation between the energy deposition and the radius of the fibres. The deposition is roughly inversely proportional to sinθ with θ the incident angle relative to the fibre axis. The results could provide corrections to the measurements of the scintillation fibres used in monitoring the γ-ray radiation

  3. Diagnosing ulnar neuropathy at the elbow using magnetic resonance neurography

    International Nuclear Information System (INIS)

    Keen, Nayela N.; Chin, Cynthia T.; Saloner, David; Steinbach, Lynne S.; Engstrom, John W.

    2012-01-01

    Early diagnosis of ulnar neuropathy at the elbow is important. Magnetic resonance neurography (MRN) images peripheral nerves. We evaluated the usefulness of elbow MRN in diagnosing ulnar neuropathy at the elbow. The MR neurograms of 21 patients with ulnar neuropathy were reviewed retrospectively. MRN was performed prospectively on 10 normal volunteers. The MR neurograms included axial T1 and axial T2 fat-saturated and/or axial STIR sequences. The sensitivity and specificity of MRN in detecting ulnar neuropathy were determined. The mean ulnar nerve size in the symptomatic and normal groups was 0.12 and 0.06 cm 2 (P 2 , sensitivity was 95% and specificity was 80%. Ulnar nerve size and signal intensity were greater in patients with ulnar neuropathy. MRN is a useful test in evaluating ulnar neuropathy at the elbow. (orig.)

  4. Ulnar nerve sonography in leprosy neuropathy.

    Science.gov (United States)

    Wang, Zhu; Liu, Da-Yue; Lei, Yang-Yang; Yang, Zheng; Wang, Wei

    2016-01-01

    A 23-year-old woman presented with a half-year history of right forearm sensory and motor dysfunction. Ultrasound imaging revealed definite thickening of the right ulnar nerve trunk and inner epineurium, along with heterogeneous hypoechogenicity and unclear nerve fiber bundle. Color Doppler exhibited a rich blood supply, which was clearly different from the normal ulnar nerve presentation with a scarce blood supply. The patient subsequently underwent needle aspiration of the right ulnar nerve, and histopathological examination confirmed that granulomatous nodules had formed with a large number of infiltrating lymphocytes and a plurality of epithelioid cells in the fibrous connective tissues, with visible atypical foam cells and proliferous vascularization, consistent with leprosy. Our report will familiarize readers with the characteristic sonographic features of the ulnar nerve in leprosy, particularly because of the decreasing incidence of leprosy in recent years.

  5. Diagnosing ulnar neuropathy at the elbow using magnetic resonance neurography

    Energy Technology Data Exchange (ETDEWEB)

    Keen, Nayela N.; Chin, Cynthia T.; Saloner, David; Steinbach, Lynne S. [University of California San Francisco, Dept of Radiology and Biomedical Imaging, San Francisco, CA (United States); Engstrom, John W. [University of California San Francisco, Department of Neurology, San Francisco, CA (United States)

    2012-04-15

    Early diagnosis of ulnar neuropathy at the elbow is important. Magnetic resonance neurography (MRN) images peripheral nerves. We evaluated the usefulness of elbow MRN in diagnosing ulnar neuropathy at the elbow. The MR neurograms of 21 patients with ulnar neuropathy were reviewed retrospectively. MRN was performed prospectively on 10 normal volunteers. The MR neurograms included axial T1 and axial T2 fat-saturated and/or axial STIR sequences. The sensitivity and specificity of MRN in detecting ulnar neuropathy were determined. The mean ulnar nerve size in the symptomatic and normal groups was 0.12 and 0.06 cm{sup 2} (P < 0.001). The mean relative signal intensity in the symptomatic and normal groups was 2.7 and 1.4 (P < 0.01). When using a size of 0.08 cm{sup 2}, sensitivity was 95% and specificity was 80%. Ulnar nerve size and signal intensity were greater in patients with ulnar neuropathy. MRN is a useful test in evaluating ulnar neuropathy at the elbow. (orig.)

  6. Ulnar nerve injury associated with trampoline injuries.

    Science.gov (United States)

    Maclin, Melvin M; Novak, Christine B; Mackinnon, Susan E

    2004-08-01

    This study reports three cases of ulnar neuropathy after trampoline injuries in children. A chart review was performed on children who sustained an ulnar nerve injury from a trampoline accident. In all cases, surgical intervention was required. Injuries included upper-extremity fractures in two cases and an upper-extremity laceration in one case. All cases required surgical exploration with internal neurolysis and ulnar nerve transposition. Nerve grafts were used in two cases and an additional nerve transfer was used in one case. All patients had return of intrinsic hand function and sensation after surgery. Children should be followed for evolution of ulnar nerve neuropathy after upper-extremity injury with consideration for electrical studies and surgical exploration if there is no improvement after 3 months.

  7. Theoretical and Experimental Study of Radial Velocity Generation for Extending Bandwidth of Magnetohydrodynamic Angular Rate Sensor at Low Frequency

    Directory of Open Access Journals (Sweden)

    Yue Ji

    2015-12-01

    Full Text Available The magnetohydrodynamics angular rate sensor (MHD ARS has received much attention for its ultra-low noise in ultra-broad bandwidth and its impact resistance in harsh environments; however, its poor performance at low frequency hinders its work in long time duration. The paper presents a modified MHD ARS combining Coriolis with MHD effect to extend the measurement scope throughout the whole bandwidth, in which an appropriate radial flow velocity should be provided to satisfy simplified model of the modified MHD ARS. A method that can generate radial velocity by an MHD pump in MHD ARS is proposed. A device is designed to study the radial flow velocity generated by the MHD pump. The influence of structure and physical parameters are studied by numerical simulation and experiment of the device. The analytic expression of the velocity generated by the energized current drawn from simulation and experiment are consistent, which demonstrates the effectiveness of the method generating radial velocity. The study can be applied to generate and control radial velocity in modified MHD ARS, which is essential for the two effects combination throughout the whole bandwidth.

  8. Investigation of angular and axial smoothing of PET data

    International Nuclear Information System (INIS)

    Daube-Witherspoon, M.E.; Carson, R.E.

    1996-01-01

    Radial filtering of emission and transmission data is routinely performed in PET during reconstruction in order to reduce image noise. Angular smoothing is not typically done, due to the introduction of a non-uniform resolution loss; axial filtering is also not usually performed on data acquired in 2D mode. The goal of this paper was to assess the effects of angular and axial smoothing on noise and resolution. Angular and axial smoothing was incorporated into the reconstruction process on the Scanditronix PC2048-15B brain PET scanner. In-plane spatial resolution and noise reduction were measured for different amounts of radial and angular smoothing. For radial positions away from the center of the scanner, noise reduction and degraded tangential resolution with no loss of radial resolution were seen. Near the center, no resolution loss was observed, but there was also no reduction in noise for angular filters up to a 7 degrees FWHM. These results can be understood by considering the combined effects of smoothing projections across rows (angles) and then summing (backprojecting). Thus, angular smoothing is not optimal due to its anisotropic noise reduction and resolution degradation properties. However, uniform noise reduction comparable to that seen with radial filtering can be achieved with axial smoothing of transmission data. The axial results suggest that combined radial and axial transmission smoothing could lead to improved noise characteristics with more isotropic resolution degradation

  9. A Comparison of Ulnar Shortening Osteotomy Alone Versus Combined Arthroscopic Triangular Fibrocartilage Complex Debridement and Ulnar Shortening Osteotomy for Ulnar Impaction Syndrome

    Science.gov (United States)

    Song, Hyun Seok

    2011-01-01

    Background This study compared the results of patients treated for ulnar impaction syndrome using an ulnar shortening osteotomy (USO) alone with those treated with combined arthroscopic debridement and USO. Methods The results of 27 wrists were reviewed retrospectively. They were divided into three groups: group A (USO alone, 10 cases), group B (combined arthroscopic debridement and USO, 9 cases), and group C (arthroscopic triangular fibrocartilage complex [TFCC] debridement alone, 8 cases). The wrist function was evaluated using the modified Mayo wrist score, disabilities of the arm, shoulder and hand (DASH) score and Chun and Palmer grading system. Results The modified Mayo wrist score in groups A, B, and C was 74.5 ± 8.9, 73.9 ± 11.6, and 61.3 ± 10.2, respectively (p 0.05). Conclusions Both USO alone and combined arthroscopic TFCC debridement with USO improved the wrist function and reduced the level of pain in the patients treated for ulnar impaction syndrome. USO alone may be the preferred method of treatment in patients if the torn flap of TFCC is not unstable. PMID:21909465

  10. Treatment of humeroulnar subluxation with a dynamic proximal ulnar osteotomy: a review of 13 cases

    International Nuclear Information System (INIS)

    Gilson, S.D.; Piermattei, D.L.; Schwarz, P.D.

    1989-01-01

    Humeroulnar subluxation was treated surgically in 13 dogs with 18 affected elbows using a proximal osteotomy of the ulna that allowed the ulna to elongate dynamically. Distal humeroulnar subluxation was secondary to premature closure of the distal ulnar physis in 16 elbows. One distal subluxation was secondary to a radioulnar synostosis, and one proximal subluxation developed after premature closure of the distal radial physis. The mean follow-up time was 22 months. Twenty-eight percent of the elbows were judged to have excellent results, 22% good results, 50% fair results, and none was judged to have a poor outcome. The presenting lameness grade and the severity of preoperative and postoperative humeroulnar subluxation had significant correlations with the prognosis. Associated orthopedic abnormalities and complications of concurrent surgical procedures affected the outcome in several dogs. Overall, the dynamic proximal ulnar osteotomy was a simple and effective technique for the treatment of uncomplicated humeroulnar subluxation

  11. Where Is the Ulnar Styloid Process? Identification of the Absolute Location of the Ulnar Styloid Process Based on CT and Verification of Neutral Forearm Rotation on Lateral Radiographs of the Wrist.

    Science.gov (United States)

    Shin, Seung-Han; Lee, Yong-Suk; Kang, Jin-Woo; Noh, Dong-Young; Jung, Joon-Yong; Chung, Yang-Guk

    2018-03-01

    The location of the ulnar styloid process can be confusing because the radius and the hand rotate around the ulna. The purpose of this study was to identify the absolute location of the ulnar styloid process, which is independent of forearm pronation or supination, to use it as a reference for neutral forearm rotation on lateral radiographs of the wrist. Computed tomography (CT) images of 23 forearms taken with elbow flexion of 70° to 90° were analyzed. The axial CT images were reconstructed to be perpendicular to the distal ulnar shaft. The absolute location of the ulnar styloid process in this study was defined as the position of the ulnar styloid process on the axial plane of the ulnar head relative to the long axis of the humeral shaft with the elbow set in the position for standard lateral radiographs of the wrist. To identify in which direction the ulnar styloid is located on the axial plane of the ulnar head, the angle between "the line of humeral long axis projected on the axial plane of the ulna" and "the line passing the center of the ulnar head and the center of the ulnar styloid" was measured (ulnar styloid direction angle). To identify how volarly or dorsally the ulnar styloid should appear on the true lateral view of the wrist, the ratio of "the volar-dorsal diameter of the ulnar head" and "the distance between the volar-most aspect of the ulnar head and the center of the ulnar styloid" was calculated (ulnar styloid location ratio). The mean ulnar styloid direction angle was 12° dorsally. The mean ulnar styloid location ratio was 1:0.55. The ulnar styloid is located at nearly the ulnar-most (the opposite side of the humerus with the elbow flexed) and slightly dorsal aspects of the ulnar head on the axial plane. It should appear almost midway (55% dorsally) from the ulnar head on the standard lateral view of the wrist in neutral forearm rotation. These location references could help clinicians determine whether the forearm is in neutral or rotated

  12. Channeling of protons through radial deformed carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Borka Jovanović, V., E-mail: vborka@vinca.rs [Atomic Physics Laboratory (040), Vinča Institute of Nuclear Sciences, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Borka, D. [Atomic Physics Laboratory (040), Vinča Institute of Nuclear Sciences, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Galijaš, S.M.D. [Faculty of Physics, University of Belgrade, P.O. Box 368, 11001 Belgrade (Serbia)

    2017-05-18

    Highlights: • For the first time we presented theoretically obtained distributions of channeled protons with radially deformed SWNT. • Our findings indicate that influence of the radial deformation is very strong and it should not be omitted in simulations. • We show that the spatial and angular distributions depend strongly of level of radial deformation of nanotube. • Our obtained results can be compared with measured distributions to reveal the presence of various types of defects in SWNT. - Abstract: In this paper we have presented a theoretical investigation of the channeling of 1 GeV protons with the radial deformed (10, 0) single-wall carbon nanotubes (SWNTs). We have calculated channeling potential within the deformed nanotubes. For the first time we presented theoretically obtained spatial and angular distributions of channeled protons with radially deformed SWNT. We used a Monte Carlo (MC) simulation technique. We show that the spatial and angular distributions depend strongly of level of radial deformation of nanotube. These results may be useful for nanotube characterization and production and guiding of nanosized ion beams.

  13. Ulnar-sided wrist pain. Part I: anatomy and physical examination

    International Nuclear Information System (INIS)

    Vezeridis, Peter S.; Blazar, Philip; Yoshioka, Hiroshi; Han, Roger

    2010-01-01

    Ulnar-sided wrist pain is a common complaint, and it presents a diagnostic challenge for hand surgeons and radiologists. The complex anatomy of this region, combined with the small size of structures and subtle imaging findings, compound this problem. A thorough understanding of ulnar-sided wrist anatomy and a systematic clinical examination of this region are essential in arriving at an accurate diagnosis. In part I of this review, ulnar-sided wrist anatomy and clinical examination are discussed for a more comprehensive understanding of ulnar-sided wrist pain. (orig.)

  14. Laser-induced radial birefringence and spin-to-orbital optical angular momentum conversion in silver-doped glasses

    International Nuclear Information System (INIS)

    Amjad, Jafar Mostafavi; Khalesifard, Hamid Reza; Slussarenko, Sergei; Karimi, Ebrahim; Santamato, Enrico; Marrucci, Lorenzo

    2011-01-01

    Samples of Ag + /Na + ion-exchanged glass that have been subject to intense laser irradiation may develop novel optical properties, as a consequence of the formation of patterns of silver nanoparticles and other structures. Here, we report the observation of a laser-induced permanent transverse birefringence, with the optical axis forming a radial pattern, as revealed by the spin-to-orbital angular momentum conversion occurring in a probe light beam. The birefringence pattern can be modeled well as resulting from thermally-induced stresses arising in the silver-doped glass during laser exposure, although the actual mechanism leading to the permanent anisotropy is probably more complex.

  15. In vivo fluoroscopic kinematography of dynamic radio-ulnar ...

    African Journals Online (AJOL)

    ... canine elbow joint, as part of the physiological kinematic pattern. However, dysplastic elbow joints do not show an increased radio-ulnar translation, and therfore dRUI cannot be considered causative for medial coronoid disease. Keywords: Canine, Elbow dysplasia, Fluoroscopy, Gait analysis, Radio-ulnar incongruence.

  16. Assessment of ulnar variance: a radiological investigation in a Dutch population

    Energy Technology Data Exchange (ETDEWEB)

    Schuurman, A.H. [Dept. of Plastic, Reconstructive and Hand Surgery, University Medical Centre, Utrecht (Netherlands); Dept. of Plastic Surgery, University Medical Centre, Utrecht (Netherlands); Maas, M.; Dijkstra, P.F. [Dept. of Radiology, Univ. of Amsterdam (Netherlands); Kauer, J.M.G. [Dept. of Anatomy and Embryology, Univ. of Nijmegen (Netherlands)

    2001-11-01

    Objective: A radiological study was performed to evaluate ulnar variance in 68 Dutch patients using an electronic digitizer compared with Palmer's concentric circle method. Using the digitizer method only, the effect of different wrist positions and grip on ulnar variance was then investigated. Finally the distribution of ulnar variance in the selected patients was investigated also using the digitizer method. Design and patients: All radiographs were performed with the wrist in a standard zero-rotation position (posteroanterior) and in supination (anteroposterior). Palmer's concentric circle method and an electronic digitizer connected to a personal computer were used to measure ulnar variance. The digitizer consists of a Plexiglas plate with an electronically activated grid beneath it. A radiograph is placed on the plate and a cursor activates a point on the grid. Three plots are marked on the radius and one plot on the most distal part of the ulnar head. The digitizer then determines the difference between a radius passing through the radius plots and the ulnar plot. Results and conclusions: Using the concentric circle method we found an ulna plus predominance, but an ulna minus predominance when using the digitizer method. Overall the ulnar variance distribution for Palmer's method was 41.9% ulna plus, 25.7% neutral and 32.4% ulna minus variance, and for the digitizer method was 40.4% ulna plus, 1.5% neutral and 58.1% ulna minus. The percentage ulnar variance greater than 1 mm on standard radiographs increased from 23% to 58% using the digitizer, with maximum grip, clearly demonstrating the (dynamic) effect of grip on ulnar variance. This almost threefold increase was found to be a significant difference. Significant differences were found between ulnar variance when different wrist positions were compared. (orig.)

  17. Influence of multi-microphone signal enhancement algorithms on the acoustics and detectability of angular and radial source movements

    DEFF Research Database (Denmark)

    Lundbeck, Micha; Hartog, Laura; Grimm, Giso

    2018-01-01

    Hearing-impaired listeners are known to have difficulties not only with understanding speech in noise, but also with judging source distance and movement, and these deficits are related to perceived handicap. It is possible that the perception of spatially dynamic sounds can be improved...... with hearing aids (HAs), but so far this has not been investigated. In a previous study, older hearing-impaired (OHI) listeners showed poorer detectability for virtual left-right (angular) and near-far (radial) source movements due to lateral interfering sounds and reverberation, respectively (Lundbeck, Grimm...

  18. Analysis of ulnar variance as a risk factor for developing scaphoid nonunion.

    Science.gov (United States)

    Lirola-Palmero, S; Salvà-Coll, G; Terrades-Cladera, F J

    2015-01-01

    Ulnar variance may be a risk factor of developing scaphoid non-union. A review was made of the posteroanterior wrist radiographs of 95 patients who were diagnosed of scaphoid fracture. All fractures with displacement less than 1mm treated conservatively were included. The ulnar variance was measured in all patients. Ulnar variance was measured in standard posteroanterior wrist radiographs of 95 patients. Eighteen patients (19%) developed scaphoid nonunion, with a mean value of ulnar variance of -1.34 (-/+ 0.85) mm (CI -2.25 - 0.41). Seventy seven patients (81%) healed correctly, and the mean value of ulnar variance was -0.04 (-/+ 1.85) mm (CI -0.46 - 0.38). A significant difference was observed in the distribution of ulnar variance (pvariance less than -1mm, and ulnar variance greater than -1mm. It appears that patients with ulnar variance less than -1mm had an OR 4.58 (CI 1.51 to 13.89) with pvariance less than -1mm have a greater risk of developing scaphoid nonunion, OR 4.58 (CI 1.51 to 13.89) with p<.007. Copyright © 2014 SECOT. Published by Elsevier Espana. All rights reserved.

  19. Cold intolerance following median and ulnar nerve injuries : prognosis and predictors

    NARCIS (Netherlands)

    Ruijs, A.C.J; Jaquet, J-B.; van Riel, W. G.; Daanen, H. A M; Hovius, S.E.R.

    This study describes the predictors for cold intolerance and the relationship to sensory recovery after median and ulnar nerve injuries. The study population consisted of 107 patients 2 to 10 years after median, ulnar or combined median and ulnar nerve injuries. Patients were asked to fill out the

  20. Cold intolerance following median and ulnar nerve injuries : prognosis and predictors

    NARCIS (Netherlands)

    Ruijs, A.C.J.; Jaquet, J.B.; Riel, W.G. van; Daanen, H.A.M.; Hovius, S.E.R.

    2007-01-01

    This study describes the predictors for cold intolerance and the relationship to sensory recovery after median and ulnar nerve injuries. The study population consisted of 107 patients 2 to 10 years after median, ulnar or combined median and ulnar nerve injuries. Patients were asked to fill out the

  1. Computer use and ulnar neuropathy: results from a case-referent study

    DEFF Research Database (Denmark)

    Andersen, JH; Frost, P.; Fuglsang-Frederiksen, A.

    2012-01-01

    We aimed to evaluate associations between vocational computer use and 1) ulnar neuropathy, and 2) ulnar neuropathy- like symptoms as distinguished by electroneurography. We identified all patients aged 18-65 years, examined at the Department of Neurophysiology on suspicion of ulnar neuropathy, 2001...... was performed by conditional logistic regression.There were a negative association between daily hours of computer use and the two outcomes of interest. Participants who reported their elbow to be in contact with their working table for 2 hours or more during the workday had an elevated risk for ulnar...

  2. Different findings in bone scintigraphy between ulnar impaction syndrome and Kienbock's disease

    International Nuclear Information System (INIS)

    Chung, J.K.; Lee, H.Y.; Lee, M.C.; Baik, G.H.

    2002-01-01

    Objectives: There is an ethnic variance on the length of the ulnar and radius. In Caucasian the length of the radius is relatively longer than the ulnar, but in Oriental the length of the ulnar is longer. This difference results in the different ethnic prevalence of ulnar impaction syndrome and Kienbock's disease, avascular necrosis of the lunate. It is important to differentiate ulnar impaction syndrome from Kienbock's disease, because they show similar symptoms but need different treatment and different method of operation. Methods: Seventeen patients with the wrist pain were enrolled in this study (mean age: 45+/-13yrs M:F=12:5). Nine patients were diagnosed as Kienbock's disease and Eight patients were diagnosed as ulnar impaction. Three to four hours after injection of 20mCi of Tc-99m MDP, bone scintigraphy images of the both hands were obtained and analyzed visually. Results: In Kienbock's disease, 8 patients showed increased uptake in the lunate with or without other carpal bones. One patient showed photon defect in the lunate. Otherwise in all patients with ulnar impaction syndrome, increased uptakes were found in the lunate, with or without increase uptake in the triquetrum or the distal ulnar, which are related to triangular fibrocartilage complex. Pin hole scintigraphy and pin hole SPECT demonstrated more precise structure of the wrist. Conclusion: We could differentiate ulnar impaction syndrome from Kienbock's disease in bone scan. We should carefully evaluate bone scintigraphic findings in patients with wrist pain

  3. Dynamic ulnar impaction syndrome in tennis players: report of two cases

    Directory of Open Access Journals (Sweden)

    Edgard de Novaes França Bisneto

    Full Text Available ABSTRACT In this report, two tennis players with symptoms of ulnar impaction syndrome are reviewed. Both players have neutral ulnar variance. These cases represent dynamic ulnar impaction syndrome, when the impact between ulna and carpus occurs during conditions of pronated grip. The literature and the treatment of these two cases are discussed.

  4. Mid-term clinical outcome of radial shortening for kienbock disease

    Directory of Open Access Journals (Sweden)

    Mohammad H Ebrahimzadeh

    2015-01-01

    Full Text Available Background: To evaluate the intermediate-term outcomes of radius shortening as a treatment for Kienbock′s disease. Materials and Methods: In a historical cohort, 16 skeletally mature patients (9 men and 7 women with Kienbock disease, who were treated with radial shortening osteotomy between 2002 and 2012, were reviewed in our study. The mean age of our patients was 30 (range 18-43 years old. According to Litchman staging, there were 7 wrists at stage II and 9 wrists at stage III (6 at stage IIIA and 3 at stage IIIB. The data of grip strength, pain (visual analog scale (VAS score, wrist range of motion (ROM, ulnar variance (according to Palmer method, and the Lichtman stage were gathered before and after surgery. We evaluated overall wrist function using the Mayo Wrist score and disabilities of the arm shoulder and hand (DASH score before surgery and at the last follow-up. Results: The average of follow-up was 7 years (range from 5 to 9 years. Preoperative ulnar variance was -1.3 mm (range from 2.5 to 1 preoperatively. The mean postoperative ulnar variance was 1 mm positive (range from 0.5 to 1.5. The VAS pain score, the mean arc of wrist flexion and extension, and grip strength improved significantly preoperatively compared to after recovery from surgery. The Lichtman stage was unchanged in nine patients, one grade worse in six patients, and one grade better in one patient. The mean DASH and Mayo scores improved significantly postoperatively compare with preoperation. Comparing preoperative positive, neuter, and negative ulnar variance, there was no significant difference in terms of VAS, DASH, and Mayo scores as well as ROM and grip strength. Conclusion: Our study shows that radius shortening surgery improves pain and disability regardless of ulnar variance.

  5. Median and ulnar neuropathies in university guitarists.

    Science.gov (United States)

    Kennedy, Rachel H; Hutcherson, Kimberly J; Kain, Jennifer B; Phillips, Alicia L; Halle, John S; Greathouse, David G

    2006-02-01

    Descriptive study. To determine the presence of median and ulnar neuropathies in both upper extremities of university guitarists. Peripheral nerve entrapment syndromes of the upper extremities are well documented in musicians. Guitarists and plucked-string musicians are at risk for entrapment neuropathies in the upper extremities and are prone to mild neurologic deficits. Twenty-four volunteer male and female guitarists (age range, 18-26 years) were recruited from the Belmont University School of Music and the Vanderbilt University Blair School of Music. Individuals were excluded if they were pregnant or had a history of recent upper extremity or neck injury. Subjects completed a history form, were interviewed, and underwent a physical examination. Nerve conduction status of the median and ulnar nerves of both upper extremities was obtained by performing motor, sensory, and F-wave (central) nerve conduction studies. Descriptive statistics of the nerve conduction study variables were computed using Microsoft Excel. Six subjects had positive findings on provocative testing of the median and ulnar nerves. Otherwise, these guitarists had normal upper extremity neural and musculoskeletal function based on the history and physical examinations. When comparing the subjects' nerve conduction study values with a chart of normal nerve conduction studies values, 2 subjects had prolonged distal motor latencies (DMLs) of the left median nerve of 4.3 and 4.7 milliseconds (normal, DMLs are compatible with median neuropathy at or distal to the wrist. Otherwise, all electrophysiological variables were within normal limits for motor, sensory, and F-wave (central) values. However, comparison studies of median and ulnar motor latencies in the same hand demonstrated prolonged differences of greater than 1.0 milliseconds that affected the median nerve in 2 additional subjects, and identified contralateral limb involvement in a subject with a prolonged distal latency. The other 20

  6. Catalystlike effect of orbital angular momentum on the conversion of transverse to three-dimensional spin states within tightly focused radially polarized beams

    Science.gov (United States)

    Han, Lei; Liu, Sheng; Li, Peng; Zhang, Yi; Cheng, Huachao; Zhao, Jianlin

    2018-05-01

    We report on the catalystlike effect of orbital angular momentum (OAM) on local spin-state conversion within the tightly focused radially polarized beams associated with optical spin-orbit interaction. It is theoretically demonstrated that the incident OAM can lead to a conversion of purely transverse spin state to a three-dimensional spin state on the focal plane. This conversion can be conveniently manipulated by altering the sign and value of the OAM. By comparing the total OAM and spin angular momentum (SAM) on the incident plane to those on the focal plane, it is indicated that the incident OAM have no participation in the angular momentum intertransfer, and just play a role as a catalyst of local SAM conversion. Such an effect of OAM sheds new light on the optical spin-orbit interaction in tight-focusing processes. The resultant three-dimensional spin states may provide more degrees of freedom in optical manipulation and spin-dependent directive coupling.

  7. Ulnar nerve entrapment by anconeus epitrochlearis ligament.

    LENUS (Irish Health Repository)

    Tiong, William H C

    2012-01-01

    Ulnar nerve entrapment at the elbow is the second most common upper limb entrapment neuropathy other than carpal tunnel syndrome. There have been many causes identified ranging from chronic aging joint changes to inflammatory conditions or systemic disorders. Among them, uncommon anatomical variants accounts for a small number of cases. Here, we report our experience in managing ulnar nerve entrapment caused by a rare vestigial structure, anconeus epitrochlearis ligament, and provide a brief review of the literature of its management.

  8. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    International Nuclear Information System (INIS)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin

    2014-01-01

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P 0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  9. Impact of ancestry and body size on sonographic ulnar nerve dimensions

    International Nuclear Information System (INIS)

    Childs, Jessie T.; Phillips, Maureen; Thoirs, Kerry A.

    2012-01-01

    Introduction: The purpose of this study was to investigate the impact that geographic ancestry and body size have on ultrasonographic measurements of the ulnar nerve size measured at the elbow. Materials and methods: We performed anthropometric measurements of body size and ultrasonographic measurements of the ulnar nerve at the elbow on 13 Vietnamese and 24 European participants. Regression analysis was used to determine the effect of body size and geographic ancestry on ulnar nerve size. Results: BMI had the greatest impact on ulnar nerve size. The short axis diameter was least resilient, and the long axis diameter was the most resilient to the effects of body size and geographic ancestry. Discussion: The long axis diameter has an apparent immunity to the influences of overall body size, arm size, or geographic ancestry and has the most potential as a sensitive discriminator between normal nerves and nerves affected by ulnar neuropathy at the elbow.

  10. Clinical and X-ray investigations on congenital radio-ulnar synostosis

    International Nuclear Information System (INIS)

    Heisel, A.

    1982-01-01

    Out of 13 patients with cogenital radio-ulnar synostosis, 10 could be subjected to clinical and X-ray examination and chromosome analysis. In all the family histories the radio-ulnar synostosis was an isolated event. In no case was definite heredity of the same malformation confirmed. In most cases the radio-ulnar synostosis was an isolated malformation. 7 patients were of female, 6 of male sex. In 5 cases the synostosis was bi-lateral, in 8 cases it was unilateral without preference of either side of the body. In 2 out of 10 patients subjected to chromosome analysis gonosomal aneuploidy was found. More often than hitherto supposed, radio-ulnar synostosis seems to be associated with lower forms of polysomia of the x-chromosomes. 15 out of 18 synostoses belonged to type II, 3 to type I. The different types represent merely differring degrees of manifestation of the same deformity occurring bilaterally in one person. All patients with radio-ulnar synostosis exhibited a high degree of functional tolerance to the malformation. The development in child age and the educational and professional record were hardly impaired. (orig./MG) [de

  11. Ulnar nerve entrapment in Guyon's canal due to a lipoma.

    Science.gov (United States)

    Ozdemir, O; Calisaneller, T; Gerilmez, A; Gulsen, S; Altinors, N

    2010-09-01

    Guyon's canal syndrome is an ulnar nerve entrapment at the wrist or palm that can cause motor, sensory or combined motor and sensory loss due to various factors . In this report, we presented a 66-year-old man admitted to our clinic with a history of intermittent pain in the left palm and numbness in 4th and 5th finger for two years. His neurological examination revealed a sensory impairment in the right fifth finger. Also, physical examination displayed a subcutaneous mobile soft tissue in ulnar side of the wrist. Electromyographic examination confirmed the diagnosis of type-1 Guyon's canal syndrome. Under axillary blockage, a lipoma compressing the ulnar nerve was excised totally and ulnar nerve was decompressed. The symptoms were improved after the surgery and patient was symptom free on 3rd postoperative week.

  12. Ulnar-sided wrist pain. II. Clinical imaging and treatment

    Energy Technology Data Exchange (ETDEWEB)

    Watanabe, Atsuya; Souza, Felipe [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); Vezeridis, Peter S.; Blazar, Philip [Brigham and Women' s Hospital, Department of Orthopaedic Surgery, Boston, MA (United States); Yoshioka, Hiroshi [Brigham and Women' s Hospital, Department of Radiology, Boston, MA (United States); University of California-Irvine, Department of Radiological Sciences, Irvine, CA (United States); UC Irvine Medical Center, Department of Radiological Sciences, Orange, CA (United States)

    2010-09-15

    Pain at the ulnar aspect of the wrist is a diagnostic challenge for hand surgeons and radiologists due to the small and complex anatomical structures involved. In this article, imaging modalities including radiography, arthrography, ultrasound (US), computed tomography (CT), CT arthrography, magnetic resonance (MR) imaging, and MR arthrography are compared with regard to differential diagnosis. Clinical imaging findings are reviewed for a more comprehensive understanding of this disorder. Treatments for the common diseases that cause the ulnar-sided wrist pain including extensor carpi ulnaris (ECU) tendonitis, flexor carpi ulnaris (FCU) tendonitis, pisotriquetral arthritis, triangular fibrocartilage complex (TFCC) lesions, ulnar impaction, lunotriquetral (LT) instability, and distal radioulnar joint (DRUJ) instability are reviewed. (orig.)

  13. Quantification of hand function by power grip and pinch strength force measurements in ulnar nerve lesion simulated by ulnar nerve block.

    Science.gov (United States)

    Wachter, Nikolaus Johannes; Mentzel, Martin; Krischak, Gert D; Gülke, Joachim

    2017-06-24

    In the assessment of hand and upper limb function, grip strength is of the major importance. The measurement by dynamometers has been established. In this study, the effect of a simulated ulnar nerve lesion on different grip force measurements was evaluated. In 25 healthy volunteers, grip force measurement was done by the JAMAR dynamometer (Fabrication Enterprises Inc, Irvington, NY) for power grip and by a pinch strength dynamometer for tip pinch strength, tripod grip, and key pinch strength. A within-subject research design was used in this prospective study. Each subject served as the control by preinjection measurements of grip and pinch strength. Subsequent measurements after ulnar nerve block were used to examine within-subject change. In power grip, there was a significant reduction of maximum grip force of 26.9% with ulnar nerve block compared with grip force without block (P force could be confirmed. However, the assessment of other dimensions of hand strength as tip pinch, tripod pinch and key pinch had more relevance in demonstrating hand strength changes resulting from an distal ulnar nerve lesion. The measurement of tip pinch, tripod grip and key pinch can improve the follow-up in hand rehabilitation. II. Copyright © 2017 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  14. ULNAR NEURITIS ASSOCIATED WITH GUN STOCK DEFORMITY FOLLOWING SUPRACONDYLAR FRACTURE OF HUMERUS

    Directory of Open Access Journals (Sweden)

    Sunita Morhan

    2014-04-01

    Full Text Available Background: This case report describes a patient who was referred to physiotherapist from a hand surgeon. Among the fractures around the elbow joint, radial head fracture and fracture of distal end of radius are common among adults. The occurrence of Supracondylar fractures are more commonly seen in children when compared to adults. One of the complications of this fracture is malunion resulting in Gun stock deformity. The main Purpose of this case report is to explore, 1. The complication associated with gunstock deformity 2. Chances of iatrogenic nerve injury after manipulation under anesthesia. 3.Long term supervised rehabilitation approach. Case Description: A 40 years old male patient referred to our Physiotherapy department by a hand surgeon. After the initial evaluation, findings revealed limitation in right elbow movement and tingling and numbness sensation in little and half of ring fingers in his right side. This patient underwent ulnar nerve transposition surgery followed by rehabilitation. His physiotherapy session includes electrotherapeutic agents for pain relief, passive mobilization of elbow and strengthening program for his flexors and extensors of elbow for a period of one year. Outcome: The outcome of the long term rehabilitation approach for a patient with ulnar neuropathy secondary to gunstock deformity after ulnar nerve transposition surgery is good. The patients tingling and numbness decreased and the range of elbow movement improved significantly. Discussion: Most common complications of fracture of distal end of humerus include malunion,ischemic contracture and nerve injuries. The relative incidence of iatrogenic nerve injuries associatedwith this fracture has been reported as being 2%-6%. Nerve injuries after Supracondylar humeral fractures occur primarily due to tenting or entrapment of the nerve on the sharp proximal humeral fragment, while iatrogenic injuries occur either during closed manipulation or percutaneous

  15. Radiological findings in three cases of paraxial radial hemimelia in goats

    International Nuclear Information System (INIS)

    Corbera, J.A.; Pulido, M.; Morales, M.; Juste, M.C.; Gutierrez, C.

    2002-01-01

    Hemimelia is a congenital abnormality characterized by the absence of a portion of the normal structures in a limb. Hemimelia is classified as transversal and paraxial and is related to genetical and environmental factors. This article shows the radiological findings observed in three different cases of paraxial hemimelia occurred in goats (radial agenesia, absence of the portion of the distal epiphysis of the radius and anomalous radius with ulnar hypoplasia). Possible causes related to these abnormalities are discussed

  16. Angular integration and inter-projection correlation effects in CT reconstruction

    International Nuclear Information System (INIS)

    Crawford, C.R.; Pele, N.J.

    1987-01-01

    CT reconstruction algorithms require snap-shot projections of an object. In order to minimize scan times, CT scanners rotate continuously which, in turn, prevents the acquisition of snap-shot projections. Acquired projections are integrals over angular position and may be correlated inter-projection. This paper shows that angular integration and inter-projection correlation introduce a radially dependent degradation of the spatial resolution and cause the image noise to vary non-linearly with radial position

  17. Angular and radial dependence of the energy response factor for LiF-TLD micro-rods in 125I permanent implant source

    International Nuclear Information System (INIS)

    Mobit, P.; Badragan, I.

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available 125 I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to 60 Co gamma rays is 1.406 ± 0.3% for a polar angle of 90 deg. and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 ± 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response. (authors)

  18. How does ulnar shortening osteotomy influence morphologic changes in the triangular fibrocartilage complex?

    Science.gov (United States)

    Yamanaka, Yoshiaki; Nakamura, Toshiyasu; Sato, Kazuki; Toyama, Yoshiaki

    2014-11-01

    Ulnar shortening osteotomy often is indicated for treatment of injuries to the triangular fibrocartilage complex (TFCC). However, the effect of ulnar shortening osteotomy on the changes in shape of the TFCC is unclear. In our study, quantitative evaluations were performed using MRI to clarify the effect of ulnar shortening on triangular fibrocartilage (TFC) thickness attributable to disc regeneration of the TFC and TFC angle attributable to the suspension effect of ulnar shortening on the TFC. The purposes of this study were (1) to compare preoperative and postoperative TFC thickness and TFC angle on MR images to quantitatively evaluate the effect of ulnar shortening osteotomy on disc regeneration and the suspension effect on the TFC; and (2) to assess whether changes in TFC thickness and TFC angle correlated with the Mayo wrist score. Between 1995 and 2008, 256 patients underwent ulnar shortening osteotomy for TFCC injuries. The minimum followup was 24 months (mean, 51 months; range, 24-210 months). A total of 79 patients (31%) with complete followup including preoperative and postoperative MR images and the Mayo wrist score was included in this retrospective study. Evaluation of the postoperative MR images and the Mayo wrist score were performed at the final followup. The remaining 177 patients did not undergo postoperative MRI, or they had a previous fracture, large tears of the disc proper, or were lost to followup. Two orthopaedists, one of whom performed the surgeries, measured the TFC thickness and the TFC angle on coronal MR images before and after surgery for each patient. Correlations of the percent change in the TFC thickness and the magnitude of TFC angle change with age, sex, postoperative MR images, extent of ulnar shortening, preoperative ulnar variance, and postoperative Mayo wrist score were assessed. Stepwise regression analysis showed a correlation between the percent change in TFC thickness and preoperative ulnar variance (R2=0.21; β=-0.33; 95

  19. Opening wedge trapezial osteotomy as possible treatment for early trapeziometacarpal osteoarthritis: a biomechanical investigation of radial subluxation, contact area, and contact pressure.

    Science.gov (United States)

    Cheema, Tahseen; Salas, Christina; Morrell, Nathan; Lansing, Letitia; Reda Taha, Mahmoud M; Mercer, Deana

    2012-04-01

    Radial subluxation and cartilage thinning have been associated with initiation and accelerated development of osteoarthritis of the trapeziometacarpal joint. Few investigators have reported on the benefits of opening wedge trapezial osteotomy for altering the contact mechanics of the trapeziometacarpal joint as a possible deterrent to the initiation or progression of osteoarthritis. We used cadaveric specimens to determine whether opening wedge osteotomy of the trapezium was successful in reducing radial subluxation of the metacarpal base and to quantify the contact area and pressure on the trapezial surface during simulated lateral pinch. We used 8 fresh-frozen specimens in this study. The flexor pollicis longus, abductor pollicis longus, adductor pollicis, abductor pollicis brevis, and flexor pollicis brevis/opponens pollicis tendons were each loaded to simulate the thumb in lateral pinch position. We measured radial subluxation from anteroposterior radiographs before and after placement of a 15° wedge. We used real-time sensors to analyze contact pressure and contact area distribution on the trapezium. Center of force in the normal joint under lateral pinch loading was primarily located in the dorsal region of the trapezium. After wedge placement, contact pressure increased in the ulnar-dorsal region by 76%. Mean contact area increased in the ulnar-dorsal region from 0.05 to 0.07 cm(2), and in the ulnar-volar region from 0.003 to 0.024 cm(2). The average reduction in joint subluxation was 64%. The 15° opening wedge osteotomy of the trapezium reduced radial subluxation of the metacarpal on the trapezium and increased contact pressure and contact area away from the diseased compartments of the trapezial surface. Trapezial osteotomy addresses the 2 preeminent theories about the initiation and progression of osteoarthritis. By reducing radial subluxation and altering contact pressure and contact area, trapezial osteotomy may prove an alternative to first

  20. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  1. The transverse force experienced by the radial head during axial loading of the forearm: A cadaveric study.

    Science.gov (United States)

    Orbay, Jorge L; Mijares, Michael R; Berriz, Cecilia G

    2016-01-01

    When designing a radial head replacement, the magnitude and direction of forces applied across the proximal radio-ulnar joint (PRUJ) and the radiocapitellar joint must be included. These designs often focus on axial loads transmitted to the radial head by the capitellum; however, the radial head also bears a significant transverse force at the PRUJ. Load transmission by the central band of the interosseous ligament induces a force component in a lateral direction perpendicular to the axis of the limb, which is borne by the articular surfaces of the proximal and distal radio-ulnar joints. The objective of this study is to establish the relationship between distally applied axial forces and proximal transverse reaction forces. Five cadaveric, human forearms with intact interosseous membranes were used to measure the magnitude of transversely-directed forces experienced by the radial head during axial loading of the forearm at the lunate fossa. A Mark-10 test stand applied a gradual and continuous axial load on the articular surface of the distal radius. A Mark-10 force gauge measured the resultant transverse force experienced by the radial head in the proximal radioulnar joint. Classical mechanics and static force analysis were applied in order to predict lateral force values that would occur when the interosseous ligament is treated as the major load transmitter between the radius and ulna. Acquired data show that the radial head bears a force in the transverse direction that averages 18% (SD 3.89%) in magnitude of the axial force applied at the wrist. This figure is in close accordance with the predicted value of 22% that was calculated by way of free-body plotting. Physiologic forearm loading results in a clinically significant transverse force component transmitted through the interosseous ligament complex. The existence of transverse forces in the human forearm may explain clinical problems seen after radial head resection and suggest that radial head implants

  2. Ulnar hammer syndrome: a systematic review of the literature.

    Science.gov (United States)

    Vartija, Larisa; Cheung, Kevin; Kaur, Manraj; Coroneos, Christopher James; Thoma, Achilleas

    2013-11-01

    Ulnar hammer syndrome is an uncommon form of arterial insufficiency. Many treatments have been described, and debate continues about the best option. The goal of this systematic review was to determine whether ulnar hammer syndrome has an occupational association, to identify the most reliable diagnostic test, and to determine the best treatment modality. A comprehensive literature search was conducted using the Cochrane Database of Systematic Reviews, the Cochrane Central Register of Controlled Trials, MEDLINE, CINAHL, and EMBASE. Data from articles meeting inclusion criteria were collected in duplicate. Methodological quality of studies was assessed using the Methodological Index for Nonrandomized Studies scale. Thirty studies were included in the systematic review. No randomized controlled trials were identified. There is low-quality evidence suggestive of an association between exposure to repetitive hand trauma and vibration and ulnar hammer syndrome. Various diagnostic investigations were used, but few were compared, making it difficult to determine the most reliable diagnostic test. Numerous nonoperative and operative treatments were reported. With nonoperative treatment, 12 percent had complete resolution and 70 percent had partial resolution of their symptoms. Of patients treated operatively, 42.5 percent had complete resolution and 42.5 percent had partial resolution of their symptoms. The heterogeneity in study design and outcome measures limits definitive conclusions about occupational association, best diagnostic test, and treatment for ulnar hammer syndrome. However, there is low-quality evidence that suggests that most patients with ulnar hammer syndrome will have partial relief of symptoms with nonoperative treatment, and operative treatment results in complete or partial resolution of symptoms in the majority of cases. Therapeutic, IV.

  3. Radial transport with perturbed magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hazeltine, R. D. [Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States)

    2015-05-15

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order.

  4. Radial transport with perturbed magnetic field

    International Nuclear Information System (INIS)

    Hazeltine, R. D.

    2015-01-01

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order

  5. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  6. Prolonged phone-call posture causes changes of ulnar motor nerve conduction across elbow.

    Science.gov (United States)

    Padua, Luca; Coraci, Daniele; Erra, Carmen; Doneddu, Pietro Emiliano; Granata, Giuseppe; Rossini, Paolo Maria

    2016-08-01

    Postures and work-hobby activities may play a role in the origin and progression of ulnar neuropathy at the elbow (UNE), whose occurrence appears to be increasing. The time spent on mobile-phone has increased in the last decades leading to an increased time spent with flexed elbow (prolonged-phone-posture, PPP). We aimed to assess the effect of PPP both in patients with symptoms of UNE and in symptom-free subjects. Patients with pure sensory symptoms of UNE and negative neurophysiological tests (MIN-UNE) and symptom-free subjects were enrolled. We evaluated ulnar motor nerve conduction velocity across elbow at baseline and after 6, 9, 12, 15, and 18min of PPP in both groups. Fifty-six symptom-free subjects and fifty-eight patients were enrolled. Globally 186 ulnar nerves from 114 subjects were studied. Conduction velocity of ulnar nerve across the elbow significantly changed over PPP time in patients with MIN-UNE, showing a different evolution between the two groups. PPP causes a modification of ulnar nerve functionality in patients with MIN-UNE. PPP may cause transient stress of ulnar nerve at elbow. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  7. HIGH ORIGIN OF SUPERFICIAL ULNAR ARTERY- A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Anjana Jayakumaran Nair

    2017-03-01

    Full Text Available BACKGROUND High origin and superficially placed ulnar artery is a rare anatomical variant that usually arises either in the axilla or arm and runs a superficial course in the forearm, enters the hand and participates in the formation of superficial palmar arch. During routine dissection of cadavers in our department, we observed a unilateral case of high origin and superficial ulnar artery in a human male cadaver. It originated from the brachial artery in the lower third of arm 4 cm above its bifurcation. From its origin, it passed downwards along the medial aspect of forearm, superficial to the flexors, entered hand superficial to the flexor retinaculum and formed superficial palmar arch. The knowledge of existence of a superficial ulnar artery is important during vascular and reconstructive surgery and also in evaluation of angiographic images. Superficial position makes it more vulnerable to trauma and more accessible to cannulation.

  8. 21 CFR 888.3810 - Wrist joint ulnar (hemi-wrist) polymer prosthesis.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Wrist joint ulnar (hemi-wrist) polymer prosthesis. 888.3810 Section 888.3810 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-wrist) polymer prosthesis. (a) Identification. A wrist joint ulnar (hemi-wrist) polymer prosthesis...

  9. Computed tomography arthrography using a radial plane view for the detection of triangular fibrocartilage complex foveal tears.

    Science.gov (United States)

    Moritomo, Hisao; Arimitsu, Sayuri; Kubo, Nobuyuki; Masatomi, Takashi; Yukioka, Masao

    2015-02-01

    To classify triangular fibrocartilage complex (TFCC) foveal lesions on the basis of computed tomography (CT) arthrography using a radial plane view and to correlate the CT arthrography results with surgical findings. We also tested the interobserver and intra-observer reliability of the radial plane view. A total of 33 patients with a suspected TFCC foveal tear who had undergone wrist CT arthrography and subsequent surgical exploration were enrolled. We classified the configurations of TFCC foveal lesions into 5 types on the basis of CT arthrography with the radial plane view in which the image slices rotate clockwise centered on the ulnar styloid process. Sensitivity, specificity, and positive predictive values were calculated for each type of foveal lesion in CT arthrography to detect foveal tears. We determined interobserver and intra-observer agreements using kappa statistics. We also compared accuracies with the radial plane views with those with the coronal plane views. Among the tear types on CT arthrography, type 3, a roundish defect at the fovea, and type 4, a large defect at the overall ulnar insertion, had high specificity and positive predictive value for the detection of foveal tears. Specificity and positive predictive values were 90% and 89% for type 3 and 100% and 100% for type 4, respectively, whereas sensitivity was 35% for type 3 and 22% for type 4. Interobserver and intra-observer agreement was substantial and almost perfect, respectively. The radial plane view identified foveal lesion of each palmar and dorsal radioulnar ligament separately, but accuracy results with the radial plane views were not statistically different from those with the coronal plane views. Computed tomography arthrography with a radial plane view exhibited enhanced specificity and positive predictive value when a type 3 or 4 lesion was identified in the detection of a TFCC foveal tear compared with historical controls. Diagnostic II. Copyright © 2015 American Society for

  10. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Association between distal ulnar morphology and extensor carpi ulnaris tendon pathology

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Connie Y.; Huang, Ambrose J.; Bredella, Miriam A.; Kattapuram, Susan V.; Torriani, Martin [General Hospital and Harvard Medical School, Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Massachusetts, Boston, MA (United States)

    2014-06-15

    The purpose of this study was to evaluate the association between distal ulnar morphology and extensor carpi ulnaris (ECU) tendon pathology. We retrospectively reviewed 71 adult wrist MRI studies with ECU tendon pathology (tenosynovitis, tendinopathy, or tear), and/or ECU subluxation. Subjects did not have a history of trauma, surgery, infection, or inflammatory arthritis. MRI studies from 46 subjects without ECU tendon pathology or subluxation were used as controls. The following morphological parameters of the distal ulna were measured independently by two readers: ulnar variance relative to radius, ulnar styloid process length, ECU groove depth and length. Subjects and controls were compared using Student's t test. Inter-observer agreement (ICC) was calculated. There was a significant correlation between negative ulnar variance and ECU tendon pathology (reader 1 [R1], P = 0.01; reader 2 [R2], P < 0.0001; R1 and R2 averaged data, P < 0.0001) and ECU tendon subluxation (P = 0.001; P = 0.0001; P < 0.0001). In subjects with ECU tendon subluxation there was also a trend toward a shorter length (P = 0.3; P <0.0001; P = 0.001) and a shallower ECU groove (P = 0.01; P = 0.03; P = 0.01; R1 and R2 averaged data with Bonferroni correction, P = 0.08). ECU groove depth (P = 0.6; P = 0.8; P = 0.9) and groove length (P = 0.1; P = 0.4; P = 0.7) showed no significant correlation with ECU tendon pathology, and length of the ulnar styloid process showed no significant correlation with ECU tendon pathology (P = 0.2; P = 0.3; P = 0.2) or subluxation (P = 0.4; P = 0.5; P = 0.5). Inter-observer agreement (ICC) was >0.64 for all parameters. Distal ulnar morphology may be associated with ECU tendon abnormalities. (orig.)

  12. Cooling modifies mixed median and ulnar palmar studies in carpal tunnel syndrome.

    Science.gov (United States)

    Araújo, Rogério Gayer Machado de; Kouyoumdjian, João Aris

    2007-09-01

    Temperature is an important and common variable that modifies nerve conduction study parameters in practice. Here we compare the effect of cooling on the mixed palmar median to ulnar negative peak-latency difference (PMU) in electrodiagnosis of carpal tunnel syndrome (CTS). Controls were 22 subjects (19 women, mean age 42.1 years, 44 hands). Patients were diagnosed with mild symptomatic CTS (25 women, mean age 46.6 years, 34 hands). PMU was obtained at the usual temperature, >32 degrees C, and after wrist/hand cooling to PMU and mixed ulnar palmar latency in patients versus controls. We concluded that cooling significantly modifies the PMU. We propose that the latencies of compressed nerve overreact to cooling and that this response could be a useful tool for incipient CTS electrodiagnosis. There was a significant latency overreaction of the ulnar nerve to cooling in CTS patients. We hypothesize that subclinical ulnar nerve compression is associated with CTS.

  13. Turbulent transport of toroidal angular momentum in low flow gyrokinetics

    International Nuclear Information System (INIS)

    Parra, Felix I; Catto, Peter J

    2010-01-01

    We derive a self-consistent equation for the turbulent transport of toroidal angular momentum in tokamaks in the low flow ordering that only requires solving gyrokinetic Fokker-Planck and quasineutrality equations correct to second order in an expansion on the gyroradius over scale length. We also show that according to our orderings the long wavelength toroidal rotation and the long wavelength radial electric field satisfy the neoclassical relation that gives the toroidal rotation as a function of the radial electric field and the radial gradients of pressure and temperature. Thus, the radial electric field can be solved for once the toroidal rotation is calculated from the transport of toroidal angular momentum. Unfortunately, even though this methodology only requires a gyrokinetic model correct to second order in gyroradius over scale length, current gyrokinetic simulations are only valid to first order. To overcome this difficulty, we exploit the smallish ratio B p /B, where B is the total magnetic field and B p is its poloidal component. When B p /B is small, the usual first order gyrokinetic equation provides solutions that are accurate enough to employ for our expression for the transport of toroidal angular momentum. We show that current δf and full f simulations only need small corrections to achieve this accuracy. Full f simulations, however, are still unable to determine the long wavelength, radial electric field from the quasineutrality equation.

  14. Spiral phase plates with radial discontinuities for the generation of multiring orbital angular momentum beams: fabrication, characterization, and application

    Science.gov (United States)

    Ruffato, Gianluca; Massari, Michele; Carli, Marta; Romanato, Filippo

    2015-11-01

    A design of spiral phase plates for the generation of multiring beams carrying orbital angular momentum (OAM) is presented. Besides the usual helical profile, these phase plates present radial π-discontinuities in correspondence of the zeros of the associated Laguerre polynomials. Samples were fabricated by electron beam lithography over glass substrates coated with a polymethylmethacrylate resist layer. The optical response was analyzed and the purity of the generated beams was investigated in terms of Laguerre-Gaussian modes contributions. The far-field intensity pattern was compared with theoretical models and numerical simulations, while the expected phase features were confirmed by interferometric analysis with a Mach-Zehnder setup. The high quality of the output beams confirms the applicability of these phase plates for the generation of high-order OAM beams with nonzero radial index. An application consisting of the design of computer-generated holograms encoding information for light beams carrying phase singularities is presented and described. A numerical code based on an iterative Fourier transform algorithm has been developed for the computation of phase-only diffractive optical element for illumination under OAM beams. Numerical analysis and preliminary experimental results confirm the applicability of these devices as high-security optical elements for anticounterfeiting applications.

  15. Mobilização do osso pisiforme no tratamento da neuropraxia do nervo ulnar no canal de Guyon: relato de caso Pisiform bone mobilization for treating ulnar nerve neuropraxia at Guyon's canal: case report

    Directory of Open Access Journals (Sweden)

    Júlio Guilherme Silva

    2009-12-01

    Full Text Available As neuropraxias do nervo ulnar são lesões bastante freqüentes que provocam efeitos deletérios, como diminuição de força muscular e parestesias; geralmente ocorrem no nível do epicôndilo medial e do túnel ulnar (canal de Guyon. São escassos os relatos referentes a técnicas de terapia manual para compressões do nervo ulnar no canal de Guyon. Este trabalho relata o uso da técnica de mobilização do pisiforme na compressão do nervo ulnar no canal de Guyon de um homem que sofreu luxação do punho direito aos 8 anos e, aos 25, queixava-se de um deficit para adução do dedo mínimo, que atrapalhava a realização de algumas atividades de vida diária. O paciente foi submetido a uma única sessão de mobilização articular do pisiforme. Após a aplicação da técnica, o sinal positivo do teste foi eliminado, restabelecendo-se a função de adução do 5o dedo. Embora carecendo de maior fundamentação teórica, pode-se afirmar que a técnica usada, de mobilização articular do osso pisiforme, é eficaz para melhora do quadro de paresia por neuropraxia do nervo ulnar no canal de Guyon.A common ulnar nerve neuropraxia is lesion that may result in muscle strength decrease and/or paresthesia; it usually takes place at medial epicondyle level and the ulnar tunnel (Guyon's canal. Studies on manual therapy techniques for ulnar nerve compression in Guyon's canal are scarce. This paper reports the use of a technique of pisiform bone mobilization for relieving ulnar nerve compression in Guyon's canal, in a man who had suffered a luxation of the right wrist at the age of 8 and, at 25, complained of adduction deficit of the fifth finger that interfered in his daily life activities. He was submitted to one session of pisiform mobilization; after the session, the positive test sign was eliminated, thus restoring the fifth finger function. Though lacking further grounding, it may be said that the technique used, of mobilizing the pisiform bone

  16. A comparison of 3-D computed tomography versus 2-D radiography measurements of ulnar variance and ulnolunate distance during forearm rotation.

    Science.gov (United States)

    Kawanishi, Y; Moritomo, H; Omori, S; Kataoka, T; Murase, T; Sugamoto, K

    2014-06-01

    Positive ulnar variance is associated with ulnar impaction syndrome and ulnar variance is reported to increase with pronation. However, radiographic measurement can be affected markedly by the incident angle of the X-ray beam. We performed three-dimensional (3-D) computed tomography measurements of ulnar variance and ulnolunate distance during forearm rotation and compared these with plain radiographic measurements in 15 healthy wrists. From supination to pronation, ulnar variance increased in all cases on the radiographs; mean ulnar variance increased significantly and mean ulnolunate distance decreased significantly. However on 3-D imaging, ulna variance decreased in 12 cases on moving into pronation and increased in three cases; neither the mean ulnar variance nor mean ulnolunate distance changed significantly. Our results suggest that the forearm position in which ulnar variance increased varies among individuals. This may explain why some patients with ulnar impaction syndrome complain of wrist pain exacerbated by forearm supination. It also suggests that standard radiographic assessments of ulnar variance are unreliable. © The Author(s) 2013.

  17. Revealing the radial modes in vortex beams

    CSIR Research Space (South Africa)

    Sephton, Bereneice C

    2016-10-01

    Full Text Available Light beams that carry orbital angular momentum are often approximated by modulating an initial beam, usually Gaussian, with an azimuthal phase variation to create a vortex beam. Such vortex beams are well defined azimuthally, but the radial profile...

  18. MRI shows thickening and altered diffusion in the median and ulnar nerves in multifocal motor neuropathy

    Energy Technology Data Exchange (ETDEWEB)

    Haakma, Wieke [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Aarhus University, Department of Forensic Medicine and Comparative Medicine Lab, Aarhus (Denmark); Jongbloed, Bas A.; Goedee, H.S.; Berg, Leonard H. van den; Pol, W.L. van der [University Medical Center Utrecht, Brain Centre Rudolf Magnus, Department of Neurology and Neurosurgery, Utrecht (Netherlands); Froeling, Martijn; Bos, Clemens; Hendrikse, Jeroen [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Leemans, Alexander [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands)

    2017-05-15

    To study disease mechanisms in multifocal motor neuropathy (MMN) with magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) of the median and ulnar nerves. We enrolled ten MMN patients, ten patients with amyotrophic lateral sclerosis (ALS) and ten healthy controls (HCs). Patients underwent MRI (in a prone position) and nerve conduction studies. DTI and fat-suppressed T2-weighted scans of the forearms were performed on a 3.0T MRI scanner. Fibre tractography of the median and ulnar nerves was performed to extract diffusion parameters: fractional anisotropy (FA), mean (MD), axial (AD) and radial (RD) diffusivity. Cross-sectional areas (CSA) were measured on T2-weighted scans. Forty-five out of 60 arms were included in the analysis. AD was significantly lower in MMN patients (2.20 ± 0.12 x 10{sup -3} mm{sup 2}/s) compared to ALS patients (2.31 ± 0.17 x 10{sup -3} mm{sup 2}/s; p < 0.05) and HCs (2.31± 0.17 x 10{sup -3} mm{sup 2}/s; p < 0.05). Segmental analysis showed significant restriction of AD, RD and MD (p < 0.005) in the proximal third of the nerves. CSA was significantly larger in MMN patients compared to ALS patients and HCs (p < 0.01). Thickening of nerves is compatible with changes in the myelin sheath structure, whereas lowered AD values suggest axonal dysfunction. These findings suggest that myelin and axons are diffusely involved in MMN pathogenesis. (orig.)

  19. Differentiating C8–T1 Radiculopathy from Ulnar Neuropathy: A Survey of 24 Spine Surgeons

    Science.gov (United States)

    Stoker, Geoffrey E.; Kim, Han Jo; Riew, K. Daniel

    2013-01-01

    Study Design Questionnaire. Objective To evaluate the ability of spine surgeons to distinguish C8–T1 radiculopathies from ulnar neuropathy. Methods Twenty-four self-rated “experienced” cervical spine surgeons completed a questionnaire with the following items. (1) If the ulnar nerve is cut at the elbow, which of the following would be numb: ulnar forearm, small and ring fingers; only the ulnar forearm; only the small and ring fingers; or none of the above? (2) Which of the following muscles are weak with C8–T1 radiculopathies but intact with ulnar neuropathy at the elbow: flexor digiti minimi brevis, flexor pollicis brevis, abductor digiti minimi, abductor pollicis brevis, adductor pollicis, opponens digiti minimi, opponens pollicis, medial lumbricals, lateral lumbricals, dorsal interossei, palmar interossei? Results Fifteen of 24 surgeons (63%) correctly answered the first question—that severing the ulnar nerve results in numbness of the fifth and fourth fingers. None correctly identified all four nonulnar, C8–T1-innervated options in the second question without naming additional muscles. Conclusion The ulnar nerve provides sensation to the fourth and fifth fingers and medial border of the hand. The medial antebrachial cutaneous nerve provides sensation to the medial forearm. The ulnar nerve innervates all intrinsic hand muscles, except the abductor and flexor pollicis brevis, opponens pollicis, and lateral two lumbricals, which are innervated by C8 and T1 via the median nerve. By examining these five muscles, one can clinically differentiate cubital tunnel syndrome from C8–T1 radiculopathies. Although all participants considered themselves to be experienced cervical spine surgeons, this study reveals inadequate knowledge regarding the clinical manifestations of C8–T1 radiculopathies and cubital tunnel syndrome. PMID:24494175

  20. Ulnar nerve entrapment in a French horn player.

    Science.gov (United States)

    Hoppmann, R A

    1997-10-01

    Nerve entrapment syndromes are frequent among musicians. Because of the demands on the musculoskeletal system and the great agility needed to per-form, musicians often present with vague complaints early in the course of entrapment, which makes the diagnosis a challenge for the clinician. Presented here is such a case of ulnar nerve entrapment at the left elbow of a French horn player. This case points out some of the difficulties in establishing a diagnosis of nerve entrapment in musicians. It also supports the theory that prolonged elbow flexion and repetitive finger movement contribute to the development of ulnar entrapment at the elbow. Although surgery is not required for most of the musculoskeletal problems of musicians, release of an entrapped nerve refractory to conservative therapy may be career-saving for the musician.

  1. Complete dislocation of the ulnar nerve at the elbow: a protective effect against neuropathy?

    Science.gov (United States)

    Leis, A Arturo; Smith, Benn E; Kosiorek, Heidi E; Omejec, Gregor; Podnar, Simon

    2017-08-01

    Recurrent complete ulnar nerve dislocation has been perceived as a risk factor for development of ulnar neuropathy at the elbow (UNE). However, the role of dislocation in the pathogenesis of UNE remains uncertain. We studied 133 patients with complete ulnar nerve dislocation to determine whether this condition is a risk factor for UNE. In all, the nerve was palpated as it rolled over the medial epicondyle during elbow flexion. Of 56 elbows with unilateral dislocation, UNE localized contralaterally in 17 elbows (30.4%) and ipsilaterally in 10 elbows (17.9%). Of 154 elbows with bilateral dislocation, 26 had UNE (16.9%). Complete dislocation decreased the odds of having UNE by 44% (odds ratio = 0.475; P =  0.028), and was associated with less severe UNE (P = 0.045). UNE occurs less frequently and is less severe on the side of complete dislocation. Complete dislocation may have a protective effect on the ulnar nerve. Muscle Nerve 56: 242-246, 2017. © 2016 Wiley Periodicals, Inc.

  2. A study on operative findings and pathogenic factors in ulnar neuropathy at the elbow.

    Science.gov (United States)

    Kojima, T; Kurihara, K; Nagano, T

    1979-01-01

    A study was made of operative findings obtained in 44 cases of ulnar nerve neuropathy at the elbow in an attempt to help elucidate the pathogenetic factors for the condition. Distinction must be made between Lig. epitrochleo-anconeum or a ligament-like thickening at the same site and the tendinous arch of M. flexor carpi ulnaris. These 2 sites constitute the entrapment points for the condition. A thick tendinous arch, Lig. epitrochleo-anconeum of M. anconeus epitrochlearis deters the ulnar nerve from being mobile, thereby contributing to the development of neuropathy with trauma acting as a precipitating factor. Dislocation of the ulnar nerve cannot be considered a factor of major etiologic significance. An important part is played by the tendinous arch in the pathogenesis of neuropathy, regardless of whether it is in association with ganglion, osteochondromatosis or osteoarthritis. In surgery for ulnar neuropathy decompression of the nerve is of primary necessity. Division of the tendinous arch is mandatory. Medial epicondylectomy may be added as required.

  3. The potential complications of open carpal tunnel release surgery to the ulnar neurovascular bundle and its branches: A cadaveric study.

    Science.gov (United States)

    Boughton, O; Adds, P J; Jayasinghe, J A P

    2010-07-01

    This study investigated the ulnar artery and the ulnar nerve and its branches in the palm to assess how frequently they may be at risk of damage during open carpal tunnel release surgery. Twenty-one formalin-embalmed cadaveric hands were dissected, and the proximity of the ulnar neurovascular bundle to two different lines of incision, the 3rd and 4th interdigital web space axis and the ring finger axis, was assessed and compared. It was found that an incision in the latter (ring finger) axis put the ulnar artery at risk in 12 of 21 specimens, whereas an incision in the former axis (3rd/4th interdigital web space) put the ulnar artery at risk in only two specimens. In 15 hands at least one structure (the ulnar artery or a branch of the ulnar nerve) was at risk in the ring finger axis compared to only seven hands in the axis of the 3rd/4th interdigital web space. We conclude that the ulnar artery and branches of the ulnar nerve are at increased risk of damage with an incision in the axis of the ring finger. The importance of using a blunt dissection technique under direct vision during surgery to identify and preserve these structures and median nerve branches is emphasized. (c) 2010 Wiley-Liss, Inc.

  4. TOPOGRAFÍA INTRANEURAL DE LA RAMA PROFUNDA DEL NERVIO ULNAR EN EL ANTEBRAZO DISTAL: ESTUDIO CADAVÉRICO. Intraneural topography of the deep branch of the ulnar nerve in the distal forearm: cadaveric study.

    Directory of Open Access Journals (Sweden)

    Joaquín García Pisón

    2016-07-01

    Full Text Available Objetivo: estudiar la topografía intraneural de la rama profunda del nervio ulnar (RPNU en el antebrazo distal en vistas a su identificación mediante disección intraneural mínima durante la transferencia del nervio del pronador cuadrado (NPC a la RPNU. Materiales y métodos: En 15 antebrazos cadavéricos se fijó el paquete vasculonervioso ulnar a los planos musculares profundos cada un centímetro tomando como referencia el hueso pisiforme. Se disecó en sentido proximal la RPNU bajo microscopio quirúrgico (Olympus OME, 4-20x y se registró su posición intraneural en base a una división en cuadrantes. Se midió la distancia desde el origen de la rama cutánea dorsal (RCD del nervio ulnar al pisiforme y se registró su relación intraneural con la RPNU. Resultados: La RPNU se individualizó hasta 69mm (41-94 proximal al hueso pisiforme, ubicándose en el cuadrante posteromedial del nervio ulnar en el 78% (67-87, el 93% (92-93 y el 100% de los casos entre los 0-2, 3-6 y 7-9 centímetros, respectivamente. La distancia pisiforme-RCD fue de 63mm (52-83. En 11 miembros la disección de la RPNU se extendió proximalmente al origen de la RCD, ubicándose siempre entre esta última y la rama superficial del nervio ulnar. Conclusiones: La topografía intraneural de la RPNU en el sitio óptimo para su sección en vistas a su anastomosis con el NPC es predecible en la mayoría de los casos, lo que confirma la viabilidad de su identificación precisa mediante disección intraneural mínima.  Objective: to assess the intraneural anatomy of the deep branch of the ulnar nerve (DBUN in the distal forearm in reference to its identification by means of minimal intraneural dissection during pronator quadratus nerve to DBUN transfers. Materials and methods: In 15 cadaveric forearms the ulnar neurovascular bundle was identified and attached to the subjacent muscles every one centimeter. Pisiform bone was used as reference. Intraneural proximal dissection of

  5. Osteosynthesis for symptomatic ulnar styloid nonunion

    International Nuclear Information System (INIS)

    Kajiwara, Ryoji; Kimori, Kenji; Kawagoe, Hiroyuki; Tsuge, Kenya; Ikuta, Yosikazu

    2008-01-01

    We reviewed cases of osteosynthesis for symptomatic ulnar styloid nonunion. Since 1998, 13 cases of ulnar styloid nonunion have been treated by osteosynthesis. The patients were 10 men and 3 women, with a mean age of 27 years (range 11-65). The nonunion site was located in the middle in one case, in the base in 8 cases, and in the epiphyseal region in 4 cases. Osteosynthesis was performed with tension band wiring in all cases, and cancellous bone graft was performed in 12 of 13 cases. Distal radioulnar joint (DRUJ) instability was found by radiograph or CT in four cases; in two of these, osteosynthesis alone did not improve DRUJ instability and additional DRUJ stabilization was performed. One patient whose treatment failed to correct nonunion did not seek further treatment. In another case, an additional surgery was performed 1 week after the initial surgery to correct displacement of the fragment. The mean follow-up period was 15 months (range 8-45 months). According to Hauck's criteria, final pain was evaluated as excellent in nine cases, good in three cases, including the case resulting in nonunion, and fair in one case. (author)

  6. Effective source size, radial, angular and energy spread of therapeutic 11C positron emitter beams produced by 12C fragmentation

    Science.gov (United States)

    Lazzeroni, Marta; Brahme, Anders

    2014-02-01

    The use of positron emitter light ion beams in combination with PET (Positron Emission Tomography) and PET-CT (Computed Tomography) imaging could significantly improve treatment verification and dose delivery imaging during radiation therapy. The present study is dedicated to the analysis of the beam quality in terms of the effective source size, as well as radial, angular and energy spread of the 11C ion beam produced by projectile fragmentation of a primary point monodirectional and monoenergetic 12C ion beam in a dedicated range shifter of different materials. This study was performed combining analytical methods describing the transport of particles in matter and the Monte Carlo code SHIELD-HIT+. A high brilliance and production yield of 11C fragments with a small effective source size and emittance is best achieved with a decelerator made of two media: a first liquid hydrogen section of about 20 cm followed by a hydrogen rich section of variable length. The calculated intensity of the produced 11C ion beam ranges from about 5% to 8% of the primary 12C beam intensity depending on the exit energy and the acceptance of the beam transport system. The angular spread is lower than 1 degree for all the materials studied, but the brilliance of the beam is the highest with the proposed mixed decelerator.

  7. Morphology and morphometry of the ulnar head of the pronator teres muscle in relation to median nerve compression at the proximal forearm.

    Science.gov (United States)

    Gurses, I A; Altinel, L; Gayretli, O; Akgul, T; Uzun, I; Dikici, F

    2016-12-01

    The pronator syndrome is a rare compression neuropathy of the median nerve. Ulnar head of the pronator teres muscle may cause compression at proximal forearm. Detailed morphologic and morphometric studies on the anatomy of the ulnar head of pronator teres is scarce. We dissected 112 forearms of fresh cadavers. We evaluated the morphology and morphometry of the ulnar head of pronator teres muscle. The average ulnar head width was 16.3±8.2mm. The median nerve passed anterior to the ulnar head at a distance of 50.4±10.7mm from the interepicondylar line. We classified the morphology of the ulnar head into 5 types. In type 1, the ulnar head was fibromuscular in 60 forearms (53.6%). In type 2, it was muscular in 23 forearms (20.5%). In type 3, it was just a fibrotic band in 18 forearms (16.1%). In type 4, it was absent in 9 forearms (8%). In type 5, the ulnar head had two arches in 2 forearms (1.8%). In 80 forearms (71.5%: types 1, 3, and 5), the ulnar head was either fibromuscular or a fibrotic band. Although the pronator syndrome is a rare compression syndrome, the ulnar head of pronator teres is reported as the major cause of entrapment in the majority of the cases. The location of the compression of the median nerve in relation to the ulnar head of pronator teres muscle and the morphology of the ulnar head is important for open or minimally-invasive surgical treatment. Sectional study. Basic science study. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  8. The effect of radial migration on galactic disks

    International Nuclear Information System (INIS)

    Vera-Ciro, Carlos; D'Onghia, Elena; Navarro, Julio; Abadi, Mario

    2014-01-01

    We study the radial migration of stars driven by recurring multi-arm spiral features in an exponential disk embedded in a dark matter halo. The spiral perturbations redistribute angular momentum within the disk and lead to substantial radial displacements of individual stars, in a manner that largely preserves the circularity of their orbits and that results, after 5 Gyr (∼40 full rotations at the disk scale length), in little radial heating and no appreciable changes to the vertical or radial structure of the disk. Our results clarify a number of issues related to the spatial distribution and kinematics of migrators. In particular, we find that migrators are a heavily biased subset of stars with preferentially low vertical velocity dispersions. This 'provenance bias' for migrators is not surprising in hindsight, for stars with small vertical excursions spend more time near the disk plane, and thus respond more readily to non-axisymmetric perturbations. We also find that the vertical velocity dispersion of outward migrators always decreases, whereas the opposite holds for inward migrators. To first order, newly arrived migrators simply replace stars that have migrated off to other radii, thus inheriting the vertical bias of the latter. Extreme migrators might therefore be recognized, if present, by the unexpectedly small amplitude of their vertical excursions. Our results show that migration, understood as changes in angular momentum that preserve circularity, can strongly affect the thin disk, but cast doubts on models that envision the Galactic thick disk as a relic of radial migration.

  9. Use of locking compression plates in ulnar fractures of 18 horses.

    Science.gov (United States)

    Jacobs, Carrie C; Levine, David G; Richardson, Dean W

    2017-02-01

    To describe the outcome, clinical findings, and complications associated with the use of the locking compression plate (LCP) for various types of ulnar fractures in horses. Retrospective case series. Client owned horses (n = 18). Medical records, radiographs, and follow-up for horses having an ulnar fracture repaired using at least 1 LCP were reviewed. Fifteen of 18 horses had fractures of the ulna only, and 3 horses had fractures of the ulna and proximal radius. All 18 horses were discharged from the hospital. Complications occurred in 5 horses; incisional infection (n = 4, 22%), implant-associated infection (n = 2, 11%), and colic (n = 1, 6%). Follow-up was available for all horses at a range of 13-120 months and 15 horses (83%) were sound for their intended purpose and 3 horses (17%) were euthanatized. One horse was euthanatized for complications associated with original injury and surgery. The LCP is a viable method of internal fixation for various types of ulnar fractures, with most horses in this series returning to soundness. © 2017 The American College of Veterinary Surgeons.

  10. Reliability of radiographic measurements for acute distal radius fractures

    International Nuclear Information System (INIS)

    Watson, Narelle J.; Asadollahi, Saeed; Parrish, Frank; Ridgway, Jacqueline; Tran, Phong; Keating, Jennifer L.

    2016-01-01

    The management of distal radial fractures is guided by the interpretation of radiographic findings. The aim of this investigation was to determine the intra- and inter-observer reliability of eight traditionally reported anatomic radiographic parameters in adults with an acute distal radius fracture. Five observers participated. All were routinely involved in making treatment decisions based on distal radius fracture radiographs. Observers performed independent repeated measurements on 30 radiographs for eight anatomical parameters: dorsal shift (mm), intra-articular gap (mm), intra-articular step (mm), palmar tilt (degrees), radial angle (degrees), radial height (mm), radial shift (mm), ulnar variance (mm). Intraclass correlation coefficients (ICCs) and the magnitude of retest errors were calculated. Measurement reliability was summarised as high (ICC > 0.80), moderate (0.60–0.80) or low (<0.60). Intra-observer reliability was high for dorsal shift and palmar tilt; moderate for radial angle, radial height, ulnar variance and radial shift; and low for intra-articular gap and step. Inter-observer reliability was high for palmar tilt; moderate for dorsal shift, ulnar variance, radial angle and radial height; and low for radial shift, intra-articular gap and step. Error magnitude (95 % confidence interval) was within 1–2 mm for intra-articular gap and step, 2–4 mm for ulnar variance, 4–6 mm for radial shift, dorsal shift and radial height, and 6–8° for radial angle and palmar tilt. Based on previous reports of critical values for palmar tilt, ulnar variance and radial angle, error margins appear small enough for measurements to be useful in guiding treatment decisions. Our findings indicate that clinicians cannot reliably measure values ≤1 mm for intra-articular gap and step when interpreting radiographic parameters using the standardised methods investigated in this study. As a guide for treatment selection, palmar tilt, ulnar variance and radial angle

  11. Ganglion Cyst Associated with Triangular Fibrocartilage Complex Tear That Caused Ulnar Nerve Compression

    Directory of Open Access Journals (Sweden)

    Ugur Anil Bingol, MD

    2015-03-01

    Full Text Available Summary: Ganglions are the most frequently seen soft-tissue tumors in the hand. Nerve compression due to ganglion cysts at the wrist is rare. We report 2 ganglion cysts arising from triangular fibrocartilage complex, one of which caused ulnar nerve compression proximal to the Guyonʼs canal, leading to ulnar neuropathy. Ganglion cysts seem unimportant, and many surgeons refrain from performing a general hand examination.

  12. The "hierarchical" Scratch Collapse Test for identifying multilevel ulnar nerve compression.

    Science.gov (United States)

    Davidge, Kristen M; Gontre, Gil; Tang, David; Boyd, Kirsty U; Yee, Andrew; Damiano, Marci S; Mackinnon, Susan E

    2015-09-01

    The Scratch Collapse Test (SCT) is used to assist in the clinical evaluation of patients with ulnar nerve compression. The purpose of this study is to introduce the hierarchical SCT as a physical examination tool for identifying multilevel nerve compression in patients with cubital tunnel syndrome. A prospective cohort study (2010-2011) was conducted of patients referred with primary cubital tunnel syndrome. Five ulnar nerve compression sites were evaluated with the SCT. Each site generating a positive SCT was sequentially "frozen out" with a topical anesthetic to allow determination of both primary and secondary ulnar nerve entrapment points. The order or "hierarchy" of compression sites was recorded. Twenty-five patients (mean age 49.6 ± 12.3 years; 64 % female) were eligible for inclusion. The primary entrapment point was identified as Osborne's band in 80 % and the cubital tunnel retinaculum in 20 % of patients. Secondary entrapment points were also identified in the following order in all patients: (1) volar antebrachial fascia, (2) Guyon's canal, and (3) arcade of Struthers. The SCT is useful in localizing the site of primary compression of the ulnar nerve in patients with cubital tunnel syndrome. It is also sensitive enough to detect secondary compression points when primary sites are sequentially frozen out with a topical anesthetic, termed the hierarchical SCT. The findings of the hierarchical SCT are in keeping with the double crush hypothesis described by Upton and McComas in 1973 and the hypothesis of multilevel nerve compression proposed by Mackinnon and Novak in 1994.

  13. Ulnar nerve lesion at the wrist and sport: A report of 8 cases compared with 45 non-sport cases.

    Science.gov (United States)

    Seror, P

    2015-04-01

    Reporting clinical and electrodiagnostic characteristics of sport-related ulnar neuropathies at the wrist. Eight sport-related and 45 non-sport-related cases from 53 ulnar neuropathies at the wrist cases over 14 years. Sport-related ulnar neuropathies at the wrist cases were due to cycling (5 cases), kayaking (2 cases), and big-game fishing (1 case). No patient had sensory complaints in ulnar digits, and all had motor impairment. Conduction across the wrist with recording on the first dorsal interosseous muscle was impaired in all cases, with conduction block in 5. Two cyclists showed bilateral ulnar neuropathies at the wrist. All cases recovered within 2 to 6 months with sport discontinuation. Distal lesions of the deep motor branch were more frequent in sport- than non-sport-related cases. The 8 sport-related ulnar neuropathies at the wrist cases involved the deep motor branch. Conduction study to the first dorsal interosseous muscle across the wrist is the key to electrodiagnostics. Bilateral cases in cyclists does not require wrist imaging. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  14. Natural roller bearing fault detection by angular measurement of true instantaneous angular speed

    Science.gov (United States)

    Renaudin, L.; Bonnardot, F.; Musy, O.; Doray, J. B.; Rémond, D.

    2010-10-01

    The challenge in many production activities involving large mechanical devices like power transmissions consists in reducing the machine downtime, in managing repairs and in improving operating time. Most online monitoring systems are based on conventional vibration measurement devices for gear transmissions or bearings in mechanical components. In this paper, we propose an alternative way of bearing condition monitoring based on the instantaneous angular speed measurement. By the help of a large experimental investigation on two different applications, we prove that localized faults like pitting in bearing generate small angular speed fluctuations which are measurable with optical or magnetic encoders. We also emphasize the benefits of measuring instantaneous angular speed with the pulse timing method through an implicit angular sampling which ensures insensitivity to speed fluctuation. A wide range of operating conditions have been tested for the two applications with varying speed, load, external excitations, gear ratio, etc. The tests performed on an automotive gearbox or on actual operating vehicle wheels also establish the robustness of the proposed methodology. By the means of a conventional Fourier transform, angular frequency channels kinematically related to the fault periodicity show significant magnitude differences related to the damage severity. Sideband effects are evidently seen when the fault is located on rotating parts of the bearing due to load modulation. Additionally, slip effects are also suspected to be at the origin of enlargement of spectrum peaks in the case of double row bearings loaded in a pure radial direction.

  15. Classification of ulnar triangular fibrocartilage complex tears. A treatment algorithm for Palmer type IB tears.

    Science.gov (United States)

    Atzei, A; Luchetti, R; Garagnani, L

    2017-05-01

    The classical definition of 'Palmer Type IB' triangular fibrocartilage complex tear, includes a spectrum of clinical conditions. This review highlights the clinical and arthroscopic criteria that enable us to categorize five classes on a treatment-oriented classification system of triangular fibrocartilage complex peripheral tears. Class 1 lesions represent isolated tears of the distal triangular fibrocartilage complex without distal radio-ulnar joint instability and are amenable to arthroscopic suture. Class 2 tears include rupture of both the distal triangular fibrocartilage complex and proximal attachments of the triangular fibrocartilage complex to the fovea. Class 3 tears constitute isolated ruptures of the proximal attachment of the triangular fibrocartilage complex to the fovea; they are not visible at radio-carpal arthroscopy. Both Class 2 and Class 3 tears are diagnosed with a positive hook test and are typically associated with distal radio-ulnar joint instability. If required, treatment is through reattachment of the distal radio-ulnar ligament insertions to the fovea. Class 4 lesions are irreparable tears due to the size of the defect or to poor tissue quality and, if required, treatment is through distal radio-ulnar ligament reconstruction with tendon graft. Class 5 tears are associated with distal radio-ulnar joint arthritis and can only be treated with salvage procedures. This subdivision of type IB triangular fibrocartilage complex tear provides more insights in the pathomechanics and treatment strategies. II.

  16. Palm to Finger Ulnar Sensory Nerve Conduction.

    Science.gov (United States)

    Davidowich, Eduardo; Nascimento, Osvaldo J M; Orsini, Marco; Pupe, Camila; Pessoa, Bruno; Bittar, Caroline; Pires, Karina Lebeis; Bruno, Carlos; Coutinho, Bruno Mattos; de Souza, Olivia Gameiro; Ribeiro, Pedro; Velasques, Bruna; Bittencourt, Juliana; Teixeira, Silmar; Bastos, Victor Hugo

    2015-12-29

    Ulnar neuropathy at the wrist (UNW) is rare, and always challenging to localize. To increase the sensitivity and specificity of the diagnosis of UNW many authors advocate the stimulation of the ulnar nerve (UN) in the segment of the wrist and palm. The focus of this paper is to present a modified and simplified technique of sensory nerve conduction (SNC) of the UN in the wrist and palm segments and demonstrate the validity of this technique in the study of five cases of type III UNW. The SNC of UN was performed antidromically with fifth finger ring recording electrodes. The UN was stimulated 14 cm proximal to the active electrode (the standard way) and 7 cm proximal to the active electrode. The normal data from amplitude and conduction velocity (CV) ratios between the palm to finger and wrist to finger segments were obtained. Normal amplitude ratio was 1.4 to 0.76. Normal CV ratio was 0.8 to 1.23.We found evidences of abnormal SNAP amplitude ratio or substantial slowing of UN sensory fibers across the wrist in 5 of the 5 patients with electrophysiological-definite type III UNW.

  17. Palm to finger ulnar sensory nerve conduction

    Directory of Open Access Journals (Sweden)

    Eduardo Davidowich

    2015-12-01

    Full Text Available Ulnar neuropathy at the wrist (UNW is rare, and always challenging to localize. To increase the sensitivity and specificity of the diagnosis of UNW many authors advocate the stimulation of the ulnar nerve (UN in the segment of the wrist and palm. The focus of this paper is to present a modified and simplified technique of sensory nerve conduction (SNC of the UN in the wrist and palm segments and demonstrate the validity of this technique in the study of five cases of type III UNW. The SNC of UN was performed antidromically with fifth finger ring recording electrodes. The UN was stimulated 14 cm proximal to the active electrode (the standard way and 7 cm proximal to the active electrode. The normal data from amplitude and conduction velocity (CV ratios between the palm to finger and wrist to finger segments were obtained. Normal amplitude ratio was 1.4 to 0.76. Normal CV ratio was 0.8 to 1.23.We found evidences of abnormal SNAP amplitude ratio or substantial slowing of UN sensory fibers across the wrist in 5 of the 5 patients with electrophysiological-definite type III UNW.

  18. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  19. Orbital angular momentum of a high-order Bessel light beam

    International Nuclear Information System (INIS)

    Volke-Sepulveda, K; Garces-Chavez, V; Chavez-Cerda, S; Arlt, J; Dholakia, K

    2002-01-01

    The orbital angular momentum density of Bessel beams is calculated explicitly within a rigorous vectorial treatment. This allows us to investigate some aspects that have not been analysed previously, such as the angular momentum content of azimuthally and radially polarized beams. Furthermore, we demonstrate experimentally the mechanical transfer of orbital angular momentum to trapped particles in optical tweezers using a high-order Bessel beam. We set transparent particles of known dimensions into rotation, where the sense of rotation can be reversed by changing the sign of the singularity. Quantitative results are obtained for rotation rates. This paper's animations are available from the Multimedia Enhancements page

  20. Paralisia do nervo ulnar na lepra sem alterações cutâneas: biópsia do ramo superficial do nervo ulnar na mão

    Directory of Open Access Journals (Sweden)

    FREITAS MARCOS R. G. DE

    1998-01-01

    Full Text Available A lepra constitui causa frequente de acometimento de nervos periféricos, em nosso meio. O sistema nervoso periférico é acometido por vezes sem que haja alterações cutâneas: é a chamada forma neurítica pura. Nessa variante, o nervo mais afetado é o ulnar. Nos casos de acometimento isolado de nervos periféricos somente a feitura de biópsia de nervo conduzirá ao diagnóstico. Assim, resolvemos realizar biópsia do ramo sensitivo superficial do nervo ulnar na mão em 17 pacientes com paresia ou paralisia desse nervo e espessamento do mesmo na altura do cotovelo. Os principais achados foram: redução do número de fibras mielínicas em 14 casos, infiltrado inflamatório em 13, fibrose em 12, desmielinização e remielinização em 9, presença de granuloma em 6 e visualização do Mycobacterium leprae em 5. Concluímos que a biópsia do ramo sensitivo superficial do nervo ulnar na mão é um bom meio diagnóstico de lepra em pacientes com acometimento desse nervo

  1. Median and ulnar neuropathies in U.S. Army Medical Command Band members.

    Science.gov (United States)

    Shaffer, Scott W; Koreerat, Nicholas R; Gordon, Lindsay B; Santillo, Douglas R; Moore, Josef H; Greathouse, David G

    2013-12-01

    Musicians have been reported as having a high prevalence of upper-extremity musculoskeletal disorders, including carpal tunnel syndrome. The purpose of this study was to determine the presence of median and ulnar neuropathies in U.S. Army Medical Command (MEDCOM) Band members at Fort Sam Houston, Texas. Thirty-five MEDCOM Band members (30 males, 5 females) volunteered to participate. There were 33 right-handed musicians, and the mean length of time in the MEDCOM Band was 12.2 yrs (range, 1-30 yrs). Subjects completed a history form, were interviewed, and underwent a physical examination of the cervical spine and bilateral upper extremities. Nerve conduction studies of the bilateral median and ulnar nerves were performed. Electrophysiological variables served as the reference standard for median and ulnar neuropathy and included distal sensory latencies, distal motor latencies, amplitudes, conduction velocities, and comparison study latencies. Ten of the 35 subjects (29%) presented with abnormal electrophysiologic values suggestive of an upper extremity mononeuropathy. Nine of the subjects had abnormal median nerve electrophysiologic values at or distal to the wrist; 2 had bilateral abnormal values. One had an abnormal ulnar nerve electrophysiologic assessment at the elbow. Nine of these 10 subjects had clinical examination findings consistent with the electrophysiological findings. The prevalence of mononeuropathies in this sample of band members is similar to that found in previous research involving civilian musicians (20-36%) and far exceeds that reported in the general population. Prospective research investigating screening, examination items, and injury prevention measures in musicians appears to be warranted.

  2. Right radial nerve dysfunction following laparoscopic sigmoid colectomy

    Directory of Open Access Journals (Sweden)

    Yoshikazu Takinami

    2014-10-01

    Full Text Available Here, we report a case of right radial nerve dysfunction following laparoscopic sigmoid colectomy under general anesthesia. A 75-year-old man was intubated without excessive retroflexion, and his upper body was held in place by lateral body positioners with protective cushions over the chest and acromioclavicular joints. The patient’s head was maintained at the center and held on the operation table with a memory-foam pillow to prevent hyperextension of the neck. The arms, abducted 80° with the forearms supinated, were held in place on the armrests with protective cushions. The surgical position was a 20° head-down lithotomy position with the right side of the body lowered by 15°. Surgery was completed successfully with no complications, and anesthesia time was 7 h and 37 min. After surgery, however, the patient complained of numbness and hypoesthesia on the radial and ulnar side, respectively, of the right arm from the elbow to the fingertips, with the boundary running between fingers 3 and 4. Dysesthesia was observed in the right fingertips of fingers 1–3. After 3 months of silver spike point low-frequency electrotherapy, hypoesthesia improved, while dysesthesia partially improved, in the dorsal area between right fingers 1 and 2.

  3. Macroscopic angular-momentum stages of Bose-Einstein condensates in toroidal traps

    International Nuclear Information System (INIS)

    Benakli, M.; Raghavan, S.; Smerzi, A.; Fantoni, S.; Shenoy, S.R.

    2001-03-01

    We study the stability of a rotating repulsive-atom Bose-Einstein condensate in a toroidal trap. The resulting macroscopic angular-momentum states with integer vorticity l spread radially, lowering rotational energies. These states are robust against vorticity-lowering decays, with estimated metastability barriers capable of sustaining large angular momenta (1 < or ∼ 10) for typical parameters. We identify the centrifugally squashed l-dependent density profile as a possible signature of condensate rotation and superfluidity. (author)

  4. A plasma solenoid driven by an Orbital Angular Momentum laser beam

    OpenAIRE

    Nuter, R.; Korneev, Ph.; Thiele, I.; Tikhonchuk, V.

    2018-01-01

    A tens of Tesla quasi-static axial magnetic field can be produced in the interaction of a short intense laser beam carrying an Orbital Angular Momentum with an underdense plasma. Three-dimensional "Particle In Cell" simulations and analytical model demonstrate that orbital angular momentum is transfered from a tightly focused radially polarized laser beam to electrons without any dissipative effect. A theoretical model describing the balistic interaction of electrons with laser shows that par...

  5. Angular momentum transport and dynamo action in the sun - Implications of recent oscillation measurements

    International Nuclear Information System (INIS)

    Gilman, P. A.; Morrow, C. A.; Deluca, E. E.

    1989-01-01

    The implications of a newly proposed picture of the sun's internal rotation (Brown et al., 1989; Morrow, 1988) for the distribution and transport of angular momentum and for the solar dynamo are considered. The new results, derived from an analysis of solar acoustic oscillations, affect understanding of how momentum is cycled in the sun and provide clues as to how and where the solar dynamo is driven. The data imply that the only significant radial gradient of angular velocity exists in a transitional region between the bottom of the convection zone, which is rotating like the solar surface, and the top of the deep interior, which is rotating rigidly at a rate intermediate between the equatorial and polar rates at the surface. Thus the radial gradient must change sign at the latitude where the angular velocity of the surface matches that of the interior. These inferences suggest that the cycle of angular momentum that produces the observed latitudinal differential rotation in the convection zone may be coupled to layers of the interior beneath the convection zone. 35 refs

  6. The distally-based island ulnar artery perforator flap for wrist defects

    Directory of Open Access Journals (Sweden)

    Karki Durga

    2007-01-01

    Full Text Available Background: Reconstruction of soft tissue defects around the wrist with exposed tendons, joints, nerves and bone represents a challenge to plastic surgeons, and such defects necessitate flap coverage to preserve hand functions and to protect its vital structures. We evaluated the use of a distally-based island ulnar artery perforator flap in patients with volar soft tissue defects around the wrist. Materials and Methods: Between June 2004 and June 2006, seven patients of soft tissue defects on the volar aspect of the wrist underwent distally-based island ulnar artery perforator flap. Out of seven patients, five were male and two patients were female. This flap was used in the reconstruction of the post road traffic accident defects in four patients and post electric burn defects in three patients. Flap was raised on one or two perforators and was rotated to 180°. Results: All flaps survived completely. Donor sites were closed primarily without donor site morbidity. Conclusion: The distally-based island Ulnar artery perforator flap is convenient, reliable, easy to manage and is a single-stage technique for reconstructing soft tissue defects of the volar aspect of the wrist. Early use of this flap allows preservation of vital structures, decreases morbidity and allows for early rehabilitation.

  7. Intra-articular Entrapment of Medial Epicondyle Fracture Fragment in Elbow Joint Dislocation Causing Ulnar Neuropraxia: A Case Report

    Directory of Open Access Journals (Sweden)

    Syed J

    2017-03-01

    Full Text Available Traumatic elbow dislocations in children are rare but most of them are complex dislocations, and in such dislocations, medial humerus epicondyle fractureis the most common associated injury. Fracture incarceration in the elbow joint occurs in 5-18% of medial humerus epicondyle fractures but ulnar neuropraxia is very rare. Open reduction internal fixation is indicated in medial humerus epicondyle fracture with fracture incarceration, ulnar neuropraxia, marked instability or open fracture. Operative treatment options include fragment excision and sutures, closed or open reduction and Kirschner wire fixation, open reduction and suture fixation, open reduction and smooth pin fixation, and open reduction and screw fixation. However, ulnar nerve transposition is debatable as good outcome had been reported with and without nerve transposition. We report a case of a 13-year old boy, who presented with right elbow dislocation and intra-articular entrapment of medial humerus epicondyle fracture fragment, complicated with sensory ulnar neuropraxia, following a fall onto his right outstretched hand in a motor vehicle accident. The elbow joint was reduced using close manipulative reduction but the fracture fragment remained entrapped post-reduction. The patient then underwent open reduction and screw fixation of the medial humerus epicondyle fracture without ulnar nerve transposition. He had good functional outcome six weeks after surgical intervention, with complete recovery of ulnar neuropraxia six months later. Currently, he is doing well at school and is active with his sporting activity.

  8. [Preliminary investigation of treatment of ulnar nerve defect by end-to-side neurorrhaphy].

    Science.gov (United States)

    Luo, Y; Wang, T; Fang, H

    1997-11-01

    In the repair of the defect of peripheral nerve, it was necessary to find an operative method with excellent therapeutic effect but simple technique. Based on the experimental study, one case of old injury of the ulnar nerve was treated by end-to-side neurorraphy with the intact median nerve. In this case the nerve defect was over 3 cm and unable to be sutured directly. The patient was followed up for fourteen months after the operation. The recovery of the sensation and the myodynamia was evaluated. The results showed that: the sensation and the motor function innervated by ulnar nerve were recovered. The function of the hand was almost recovered to be normal. It was proved that the end-to-side neurorraphy between the distal stump with the intact median nerve to repair the defect of the ulnar nerve was a new operative procedure for nerve repair. Clinically it had good effect with little operative difficulty. This would give a bright prospect to repair of peripheral nerve defect in the future.

  9. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    International Nuclear Information System (INIS)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor; Kranz, Gottfried; Sycha, Thomas; Hold, Alina

    2015-01-01

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  10. MR neurography of ulnar nerve entrapment at the cubital tunnel: a diffusion tensor imaging study

    Energy Technology Data Exchange (ETDEWEB)

    Breitenseher, Julia B.; Berzaczy, Dominik; Nemec, Stefan F.; Weber, Michael; Prayer, Daniela; Kasprian, Gregor [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Kranz, Gottfried; Sycha, Thomas [Medical University of Vienna, Department of Neurology, Vienna (Austria); Hold, Alina [Medical University of Vienna, Department of Plastic and Reconstructive Surgery, Vienna (Austria)

    2015-07-15

    MR neurography, diffusion tensor imaging (DTI) and tractography at 3 Tesla were evaluated for the assessment of patients with ulnar neuropathy at the elbow (UNE). Axial T2-weighted and single-shot DTI sequences (16 gradient encoding directions) were acquired, covering the cubital tunnel of 46 patients with clinically and electrodiagnostically confirmed UNE and 20 healthy controls. Cross-sectional area (CSA) was measured at the retrocondylar sulcus and FA and ADC values on each section along the ulnar nerve. Three-dimensional nerve tractography and T2-weighted neurography results were independently assessed by two raters. Patients showed a significant reduction of ulnar nerve FA values at the retrocondylar sulcus (p = 0.002) and the deep flexor fascia (p = 0.005). At tractography, a complete or partial discontinuity of the ulnar nerve was found in 26/40 (65 %) of patients. Assessment of T2 neurography was most sensitive in detecting UNE (sensitivity, 91 %; specificity, 79 %), followed by tractography (88 %/69 %). CSA and FA measurements were less effective in detecting UNE. T2-weighted neurography remains the most sensitive MR technique in the imaging evaluation of clinically manifest UNE. DTI-based neurography at 3 Tesla supports the MR imaging assessment of UNE patients by adding quantitative and 3D imaging data. (orig.)

  11. Channeling of protons in various types of radially compressed carbon nanotubes

    International Nuclear Information System (INIS)

    Karabarbounis, A.; Sarros, S.; Trikalinos, Ch.

    2015-01-01

    Channeling of 10 MeV protons in various types of radially compressed chiral carbon nanotubes is considered. Monte Carlo simulation program is used for the calculation of the trajectories, energy losses and angular distributions of protons in nanotubes of various lengths, where the potential in Doyle–Turner approximation is used to describe the interaction between a proton and a nanotube. Carbon nanotubes, which are considered, are radially compressed at the centre or at both ends. The results show that in some cases a decreased angular distribution of the beam is observed, compared with propagation through a straight nanotube. Furthermore, the energy distribution of channeled protons in nanotubes present a series of small peaks besides a main one, the number of which depends on the nanotube length and the angle of incidence, which in some cases are significantly high

  12. Channeling of protons in various types of radially compressed carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Karabarbounis, A. [Department of Physics, Section of Nuclear and Particle Physics, University of Athens, Panepistimioupolis, Ilissia, 15771 Athens (Greece); Sarros, S., E-mail: stsarros@phys.uoa.gr [Department of Physics, Section of Nuclear and Particle Physics, University of Athens, Panepistimioupolis, Ilissia, 15771 Athens (Greece); Trikalinos, Ch. [Department of Philosophy and History of Science, University of Athens, Panepistimioupolis, Ilissia, 15771 Athens (Greece)

    2015-07-15

    Channeling of 10 MeV protons in various types of radially compressed chiral carbon nanotubes is considered. Monte Carlo simulation program is used for the calculation of the trajectories, energy losses and angular distributions of protons in nanotubes of various lengths, where the potential in Doyle–Turner approximation is used to describe the interaction between a proton and a nanotube. Carbon nanotubes, which are considered, are radially compressed at the centre or at both ends. The results show that in some cases a decreased angular distribution of the beam is observed, compared with propagation through a straight nanotube. Furthermore, the energy distribution of channeled protons in nanotubes present a series of small peaks besides a main one, the number of which depends on the nanotube length and the angle of incidence, which in some cases are significantly high.

  13. Radially sheared azimuthal flows and turbulent transport in a cylindrical helicon plasma device

    International Nuclear Information System (INIS)

    Tynan, G R; Burin, M J; Holland, C; Antar, G; Diamond, P H

    2004-01-01

    A radially sheared azimuthal flow is observed in a cylindrical helicon plasma device. The shear flow is roughly azimuthally symmetric and contains both time-stationary and slowly varying components. The turbulent radial particle flux is found to peak near the density gradient maximum and vanishes at the shear layer location. The shape of the radial plasma potential profile associated with the azimuthal E x B flow is predicted accurately by theory. The existence of the mean shear flow in a plasma with finite flow damping from ion-neutral collisions and no external momentum input implies the existence of radial angular momentum transport from the turbulent Reynolds-stress

  14. Ulnar neuropathy and medial elbow pain in women's fastpitch softball pitchers: a report of 6 cases.

    Science.gov (United States)

    Smith, Adam M; Butler, Thomas H; Dolan, Michael S

    2017-12-01

    Elite-level women's fastpitch softball players place substantial biomechanical strains on the elbow that can result in medial elbow pain and ulnar neuropathic symptoms. There is scant literature reporting the expected outcomes of the treatment of these injuries. This study examined the results of treatment in a series of these patients. We identified 6 female softball pitchers (4 high school and 2 collegiate) with medial elbow pain and ulnar neuropathic symptoms. Trials of conservative care failed in all 6, and they underwent surgical treatment with subcutaneous ulnar nerve transposition. These patients were subsequently monitored postoperatively to determine outcome. All 6 female pitchers had early resolution of elbow pain and neuropathic symptoms after surgical treatment. Long-term follow-up demonstrated that 1 patient quit playing softball because of other injuries but no longer reported elbow pain or paresthesias. One player was able to return to pitching at the high school level but had recurrent forearm pain and neuritis 1 year later while playing a different sport and subsequently stopped playing competitive sports. Four patients continued to play at the collegiate level without further symptoms. Medial elbow pain in women's softball pitchers caused by ulnar neuropathy can be treated effectively with subcutaneous ulnar nerve transposition if nonsurgical options fail. Further study is necessary to examine the role of overuse, proper training techniques, and whether pitching limits may be necessary to avoid these injuries. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Intermuscular aponeuroses between the flexor muscles of the forearm and their relationships with the ulnar nerve.

    Science.gov (United States)

    Won, Hyung-Sun; Liu, Hong-Fu; Kim, Jun-Ho; Kwak, Dai-Soon; Chung, In-Hyuk; Kim, In-Beom

    2016-12-01

    The aim of this study was to clarify the morphological characteristics of the intermuscular aponeurosis between the flexor carpi ulnaris (FCU) and flexor digitorum superficialis (FDS; IMAS), and that between the FCU and flexor digitorum profundus (FDP; IMAP), and their topographic relationships with the ulnar nerve. Fifty limbs of 38 adult cadavers were studied. The IMAS extended along the deep surface of the FCU adjoining the FDS, having the appearance of a ladder, giving off "steps" that decreased in width from superficial to deep around the middle of the forearm. Its proximal part divided into two bands connected by a thin membrane, and was attached to the medial epicondyle and the tubercle (the most medial prominent part of the coronoid process of the ulna), respectively. The IMAP extended deep between the FCU and FDP from the antebrachial fascia, and its distal end was located on the posterior border of the FCU. The IMAP became broader toward its proximal part, and its proximal end was attached anterior and posterior to the tubercle and the olecranon, respectively. The ulnar nerve passed posterior to the medial epicondyle and then medial to the tubercle, and was crossed by the deep border of the IMAS at 58.3 ± 14.1 mm below the medial epicondyle. The deep border of the IMAS and aberrant tendinous structure passing across the ulnar nerve, or the parts of the IMAS and IMAP passing posterior to the ulnar nerve are potential causes of ulnar nerve compression.

  16. Giant-Cell Tumor of the Distal Ulna Treated by Wide Resection and Ulnar Support Reconstruction: A Case Report

    Directory of Open Access Journals (Sweden)

    Akio Minami

    2010-01-01

    Full Text Available Giant-cell tumor of bone occurred in the distal end of the ulna is extremely uncommon. A 23-year-old male had a giant-cell tumor occurred in the distal end of the ulna. After wide resection of the distal segment of the ulna including giant-cell tumor, ulnar components of the wrist joint were reconstructed with modified Sauvé-Kapandji procedure using the iliac bone graft, preserving the triangular fibrocartilage complex and ulnar collateral ligament in order to maintain ulnar support of the wrist, and the proximal stump of the resected ulna was stabilized by tenodesis using the extensor carpi ulnaris tendon. One year after operation, the patient's wrist was pain-free and had a full range of motion. Postoperative X-rays showed no abnormal findings including recurrence of the giant-cell tumor and ulnar translation of the entire carpus. The stability of the proximal stump of the distal ulna was also maintained.

  17. Improved WKB radial wave functions in several bases

    International Nuclear Information System (INIS)

    Durand, B.; Durand, L.; Department of Physics, University of Wisconsin, Madison, Wisconsin 53706)

    1986-01-01

    We develop approximate WKB-like solutions to the radial Schroedinger equation for problems with an angular momentum barrier using Riccati-Bessel, Coulomb, and harmonic-oscillator functions as basis functions. The solutions treat the angular momentum singularity near the origin more accurately in leading approximation than the standard WKB solutions based on sine waves. The solutions based on Riccati-Bessel and free Coulomb wave functions continue smoothly through the inner turning point and are appropriate for scattering problems. The solutions based on oscillator and bound Coulomb wave functions incorporate both turning points smoothly and are particularly appropriate for bound-state problems; no matching of piecewise solutions using Airy functions is necessary

  18. A new uncertainty relation for angular momentum and angle

    International Nuclear Information System (INIS)

    Kranold, H.U.

    1984-01-01

    An uncertainty relation of the form ΔL 2 ΔSo >=sup(h/2π)/sub(2) is derived for angular momentum and angle. The non-linear operator So measures angles and has a simple interpretation. Subject to very general conditions of rotational invariance the above relation is unique. Radial momentum is not quantized

  19. Sleeve bridging of the rhesus monkey ulnar nerve with muscular branches of the pronator teres: multiple amplification of axonal regeneration

    Directory of Open Access Journals (Sweden)

    Yu-hui Kou

    2015-01-01

    Full Text Available Multiple-bud regeneration, i.e., multiple amplification, has been shown to exist in peripheral nerve regeneration. Multiple buds grow towards the distal nerve stump during proximal nerve fiber regeneration. Our previous studies have verified the limit and validity of multiple amplification of peripheral nerve regeneration using small gap sleeve bridging of small donor nerves to repair large receptor nerves in rodents. The present study sought to observe multiple amplification of myelinated nerve fiber regeneration in the primate peripheral nerve. Rhesus monkey models of distal ulnar nerve defects were established and repaired using muscular branches of the right forearm pronator teres. Proximal muscular branches of the pronator teres were sutured into the distal ulnar nerve using the small gap sleeve bridging method. At 6 months after suture, two-finger flexion and mild wrist flexion were restored in the ulnar-sided injured limbs of rhesus monkey. Neurophysiological examination showed that motor nerve conduction velocity reached 22.63 ± 6.34 m/s on the affected side of rhesus monkey. Osmium tetroxide staining demonstrated that the number of myelinated nerve fibers was 1,657 ± 652 in the branches of pronator teres of donor, and 2,661 ± 843 in the repaired ulnar nerve. The rate of multiple amplification of regenerating myelinated nerve fibers was 1.61. These data showed that when muscular branches of the pronator teres were used to repair ulnar nerve in primates, effective regeneration was observed in regenerating nerve fibers, and functions of the injured ulnar nerve were restored to a certain extent. Moreover, multiple amplification was subsequently detected in ulnar nerve axons.

  20. Sleeve bridging of the rhesus monkey ulnar nerve with muscular branches of the pronator teres: multiple amplification of axonal regeneration.

    Science.gov (United States)

    Kou, Yu-Hui; Zhang, Pei-Xun; Wang, Yan-Hua; Chen, Bo; Han, Na; Xue, Feng; Zhang, Hong-Bo; Yin, Xiao-Feng; Jiang, Bao-Guo

    2015-01-01

    Multiple-bud regeneration, i.e., multiple amplification, has been shown to exist in peripheral nerve regeneration. Multiple buds grow towards the distal nerve stump during proximal nerve fiber regeneration. Our previous studies have verified the limit and validity of multiple amplification of peripheral nerve regeneration using small gap sleeve bridging of small donor nerves to repair large receptor nerves in rodents. The present study sought to observe multiple amplification of myelinated nerve fiber regeneration in the primate peripheral nerve. Rhesus monkey models of distal ulnar nerve defects were established and repaired using muscular branches of the right forearm pronator teres. Proximal muscular branches of the pronator teres were sutured into the distal ulnar nerve using the small gap sleeve bridging method. At 6 months after suture, two-finger flexion and mild wrist flexion were restored in the ulnar-sided injured limbs of rhesus monkey. Neurophysiological examination showed that motor nerve conduction velocity reached 22.63 ± 6.34 m/s on the affected side of rhesus monkey. Osmium tetroxide staining demonstrated that the number of myelinated nerve fibers was 1,657 ± 652 in the branches of pronator teres of donor, and 2,661 ± 843 in the repaired ulnar nerve. The rate of multiple amplification of regenerating myelinated nerve fibers was 1.61. These data showed that when muscular branches of the pronator teres were used to repair ulnar nerve in primates, effective regeneration was observed in regenerating nerve fibers, and functions of the injured ulnar nerve were restored to a certain extent. Moreover, multiple amplification was subsequently detected in ulnar nerve axons.

  1. Radial and tangential friction in heavy ion strongly damped collisions

    International Nuclear Information System (INIS)

    Jain, A.K.; Sarma, N.

    1979-01-01

    Deeply inelastic heavy ion collisions have been successfully described in terms of a nucleon exchange mechanism between two nucleon clouds. This model has also predicted the large angular momentum that is induced in the colliding nuclei. However computations were simplified in the earlier work by assuming that the friction was perturbation on the elastic scattering trajectory. Results of a more rigorous calculation are reported and the effect of modification of the trajectory on the energy transfer, the angular momentum induced and on the ratio of the radial to the tangential friction coefficients is reported. (auth.)

  2. Reliability, reference values and predictor variables of the ulnar sensory nerve in disease free adults.

    Science.gov (United States)

    Ruediger, T M; Allison, S C; Moore, J M; Wainner, R S

    2014-09-01

    The purposes of this descriptive and exploratory study were to examine electrophysiological measures of ulnar sensory nerve function in disease free adults to determine reliability, determine reference values computed with appropriate statistical methods, and examine predictive ability of anthropometric variables. Antidromic sensory nerve conduction studies of the ulnar nerve using surface electrodes were performed on 100 volunteers. Reference values were computed from optimally transformed data. Reliability was computed from 30 subjects. Multiple linear regression models were constructed from four predictor variables. Reliability was greater than 0.85 for all paired measures. Responses were elicited in all subjects; reference values for sensory nerve action potential (SNAP) amplitude from above elbow stimulation are 3.3 μV and decrement across-elbow less than 46%. No single predictor variable accounted for more than 15% of the variance in the response. Electrophysiologic measures of the ulnar sensory nerve are reliable. Absent SNAP responses are inconsistent with disease free individuals. Reference values recommended in this report are based on appropriate transformations of non-normally distributed data. No strong statistical model of prediction could be derived from the limited set of predictor variables. Reliability analyses combined with relatively low level of measurement error suggest that ulnar sensory reference values may be used with confidence. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  3. Sonography of injury of the ulnar collateral ligament of the elbow - initial experience

    International Nuclear Information System (INIS)

    Miller, Theodore T.; Adler, Ronald S.; Friedman, Lawrence

    2004-01-01

    The purpose of this study is to describe the sonographic appearance of injuries of the ulnar collateral ligament (UCL) of the elbow. Eight non-professional male baseball pitchers, ages 13-35 years, with medial elbow pain and clinical suspicion of ulnar collateral ligament injury, were referred for imaging. All eight underwent sonography of the affected and contralateral asymptomatic elbow, and six also underwent MR imaging. Neither valgus stress nor power Doppler was used during the sonographic examinations. Time from onset of symptoms to imaging was 1.5 weeks to 6 months. Three patients had surgical confirmation of their injuries, with time from imaging to surgery of 2 days to 9 months. In four patients, the UCL was ruptured, manifest sonographically in three cases as discontinuity of the normally hyperechoic ligament with anechoic fluid in the gap and in one case as non-visualization of the ligament with heterogeneous echogenicity in the expected location of the ligament. Two adolescent patients had avulsions of the UCL from the medial epicondyle, with sonographic demonstration of the avulsed echogenic bony fragment in both cases. One patient had a mild sprain, manifest as mild thickening and decreased echogenicity of the ligament sonographically compared with the contralateral normal elbow, with mild surrounding hypoechoic edema. The eighth patient had a small partial tear of the deep surface of the distal aspect of the ligament, visualized as a hypoechoic focus between the deep surface of the ligament and its ulnar attachment. Tears of the ulnar collateral ligament are manifested sonographically as non-visualization of the ligament or alteration of the normal morphology. (orig.)

  4. Severe Ulnar Nerve Injury After Bee Venom Acupuncture at a Traditional Korean Medicine Clinic: A Case Report.

    Science.gov (United States)

    Park, Joon Sang; Park, Yoon Ghil; Jang, Chul Hoon; Cho, Yoo Na; Park, Jung Hyun

    2017-06-01

    This case report describes a severe nerve injury to the right ulnar nerve, caused by bee venom acupuncture. A 52-year-old right-handed man received bee venom acupuncture on the medial side of his right elbow and forearm, at a Traditional Korean Medicine (TKM) clinic. Immediately after acupuncture, the patient experienced pain and swelling on the right elbow. There was further development of weakness of the right little finger, and sensory changes on the ulnar dermatome of the right hand. The patient visited our clinic 7 days after acupuncture. Electrodiagnostic studies 2 weeks after the acupuncture showed ulnar nerve damage. The patient underwent steroid pulse and rehabilitation treatments. However, his condition did not improve completely, even 4 months after acupuncture.

  5. Handlebar palsy--a compression syndrome of the deep terminal (motor) branch of the ulnar nerve in biking.

    Science.gov (United States)

    Capitani, Daniel; Beer, Serafin

    2002-10-01

    We describe 3 patients who developed a severe palsy of the intrinsic ulnar supplied hand muscles after bicycle riding. Clinically and electrophysiologically all showed an isolated lesion of the deep terminal motor branch of the ulnar nerve leaving the hypothenar muscle and the distal sensory branch intact. This type of lesion at the canal of Guyon is quite unusual, caused in the majority of cases by chronic external pressure over the ulnar palm. In earlier reports describing this lesion in bicycle riders, most patients experienced this lesion after a long distance ride. Due to the change of riding position and shape of handlebars (horn handle) in recent years, however, even a single bicycle ride may be sufficient to cause a lesion of this ulnar branch. Especially in downhill riding, a large part of the body weight is supported by the hand on the corner of the handlebar leading to a high load at Guyon's canal. As no sensory fibres are affected, the patients are not aware of the ongoing nerve compression until a severe lesion develops. Individual adaptation of the handlebar and riding position seems to be crucial for prevention of this type of nerve lesion.

  6. Angular Momentum Transport in Turbulent Flow between Independently Rotating Cylinders

    International Nuclear Information System (INIS)

    Paoletti, M. S.; Lathrop, D. P.

    2011-01-01

    We present measurements of the angular momentum flux (torque) in Taylor-Couette flow of water between independently rotating cylinders for all regions of the (Ω 1 , Ω 2 ) parameter space at high Reynolds numbers, where Ω 1 (Ω 2 ) is the inner (outer) cylinder angular velocity. We find that the Rossby number Ro=(Ω 1 -Ω 2 )/Ω 2 fully determines the state and torque G as compared to G(Ro=∞)≡G ∞ . The ratio G/G ∞ is a linear function of Ro -1 in four sections of the parameter space. For flows with radially increasing angular momentum, our measured torques greatly exceed those of previous experiments [Ji et al., Nature (London), 444, 343 (2006)], but agree with the analysis of Richard and Zahn [Astron. Astrophys. 347, 734 (1999)].

  7. Analysis on Coupled Vibration of a Radially Polarized Piezoelectric Cylindrical Transducer

    Directory of Open Access Journals (Sweden)

    Jie Xu

    2017-12-01

    Full Text Available Coupled vibration of a radially polarized piezoelectric cylindrical transducer is analyzed with the mechanical coupling coefficient method. The method has been utilized to analyze the metal cylindrical transducer and the axially polarized piezoelectric cylindrical transducer. In this method, the mechanical coupling coefficient is introduced and defined as the stress ratio in different directions. Coupled vibration of the cylindrical transducer is regarded as the interaction of the plane radial vibration of a ring and the longitudinal vibration of a tube. For the radially polarized piezoelectric cylindrical transducer, the radial and longitudinal electric admittances as functions of mechanical coupling coefficients and angular frequencies are derived, respectively. The resonance frequency equations are obtained. The dependence of resonance frequency and mechanical coupling coefficient on aspect ratio is studied. Vibrational distributions on the surfaces of the cylindrical transducer are presented with experimental measurement. On the support of experiments, this work is verified and provides a theoretical foundation for the analysis and design of the radially polarized piezoelectric cylindrical transducer.

  8. The effect of distal ulnar implant stem material and length on bone strains.

    Science.gov (United States)

    Austman, Rebecca L; Beaton, Brendon J B; Quenneville, Cheryl E; King, Graham J W; Gordon, Karen D; Dunning, Cynthia E

    2007-01-01

    Implant design parameters can greatly affect load transfer from the implant stem to the bone. We have investigated the effect of length or material of distal ulnar implant stems on the surrounding bone strains. Eight cadaveric ulnas were instrumented with 12 strain gauges and secured in a customized jig. Strain data were collected while loads (5-30 N) were applied to the medial surface of the native ulnar head. The native ulnar head was removed, and a stainless steel implant with an 8-cm-long finely threaded stem was cemented into the canal. After the cement had cured, the 8-cm stem was removed, leaving a threaded cement mantle in the canal that could accept shorter threaded stems of interest. The loading protocol was then repeated for stainless steel stems that were 7, 5, and 3 cm in length, as well as for a 5-cm-long titanium alloy (TiAl(6)V(4)) stem. Other stainless steel stem lengths between 3 and 7 cm were tested at intervals of 0.5 cm, with only a 20 N load applied. No stem length tested matched the native strains at all gauge locations. No significant differences were found between any stem length and the native bone at the 5th and 6th strain gauge positions. Strains were consistently closer to the native bone strains with the titanium stem than the stainless steel stem for each gauge pair that was positioned on the bone overlying the stem. The 3-cm stem results were closer to the native strains than the 7-cm stem for all loads at gauges locations that were on top of the stem. The results from this study suggest that the optimal stem characteristics for distal ulnar implants from a load transfer point of view are possessed by shorter (approximately 3 to 4 cm) titanium stems.

  9. A program for performing angular integrations for transition operators

    International Nuclear Information System (INIS)

    Froese Fischer, C.; Godefroid, M.R.; Hibbert, A.

    1991-01-01

    The MCHF-MLTPOL program performs the angular integrations necessary for expressing the matrix elements of transition operators, E1, E2, ..., or M1, M2, ..., as linear combinations of radial integrals. All matrix elements for transitions between two lists of configuration states will be evaluated. A limited amount of non-orthogonality is allowed between orbitals of the initial and final state. (orig.)

  10. Angular momentum coupling in atom-atom collisions

    International Nuclear Information System (INIS)

    Grosser, J.

    1986-01-01

    The coupling between the electronic angular momentum and the rotating atom-atom axis in the initial or the final phase of an atom-atom collision is discussed, making use of the concepts of radial and rotational (Coriolis) coupling between different molecular states. The description is based on a limited number of well-understood approximations, and it allows an illustrative geometric representation of the transition from the body fixed to the space fixed motion of the electrons. (orig.)

  11. Scaphoid and lunate movement in different ranges of carpal radioulnar deviation.

    Science.gov (United States)

    Tang, Jin Bo; Xu, Jing; Xie, Ren Guo

    2011-01-01

    We aimed to investigate scaphoid and lunate movement in radial deviation and in slight and moderate ulnar deviation ranges in vivo. We obtained computed tomography scans of the right wrists from 20° radial deviation to 40° ulnar deviation in 20° increments in 6 volunteers. The 3-dimensional bony structures of the wrist, including the distal radius and ulna, were reconstructed with customized software. The changes in position of the scaphoid and lunate along flexion-extension motion (FEM), radioulnar deviation (RUD), and supination-pronation axes in 3 parts--radial deviation and slight and moderate ulnar deviation--of the carpal RUD were calculated and analyzed. During carpal RUD, scaphoid and lunate motion along 3 axes--FEM, RUD, and supination-pronation--were the greatest in the middle third of the measured RUD (from neutral position to 20° ulnar deviation) and the smallest in radial deviation. Scaphoid motion along the FEM, RUD, and supination-pronation axes in the middle third was about half that in the entire motion range. In the middle motion range, lunate movement along the FEM and RUD axes was also the greatest. During carpal RUD, the greatest scaphoid and lunate movement occurs in the middle of the arc--slight ulnar deviation--which the wrist frequently adopts to accomplish major hand actions. At radial deviation, scaphoid and lunate motion is the smallest. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  12. Radial reflection diffraction tomography

    Science.gov (United States)

    Lehman, Sean K.

    2012-12-18

    A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.

  13. Reversed Palmaris Longus Muscle Causing Volar Forearm Pain and Ulnar Nerve Paresthesia.

    Science.gov (United States)

    Bhashyam, Abhiram R; Harper, Carl M; Iorio, Matthew L

    2017-04-01

    A case of volar forearm pain associated with ulnar nerve paresthesia caused by a reversed palmaris longus muscle is described. The patient, an otherwise healthy 46-year-old male laborer, presented after a previous unsuccessful forearm fasciotomy for complaints of exercise exacerbated pain affecting the volar forearm associated with paresthesia in the ulnar nerve distribution. A second decompressive fasciotomy was performed revealing an anomalous "reversed" palmaris longus, with the muscle belly located distally. Resection of the anomalous muscle was performed with full relief of pain and sensory symptoms. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. Analysis of the Papal Benediction Sign: The ulnar neuropathy of St. Peter.

    Science.gov (United States)

    Futterman, Bennett

    2015-09-01

    The origin of the Papal Benediction Sign has been a source of controversy for many generations of medical students. The question has been whether the Papal Benediction Sign posture is the result of an injury to the median nerve or to the ulnar nerve. The increasingly popular use of online "chat rooms" and the vast quantities of information available on the internet has led to an increasing level of confusion. Looking in major anatomy texts, anatomy and board review books as well as numerous internet sites the answer remains unresolved. Through the analysis of functional anatomy of the hand, cultural and religious practices of the early centuries of the Common Era and church art a clear answer emerges. It will become apparent that this hand posture results from an ulnar neuropathy. Copyright © 2015 Wiley Periodicals, Inc.

  15. Pure neuritic leprosy presenting as ulnar nerve neuropathy: a case report of electrodiagnostic, radiographic, and histopathological findings.

    Science.gov (United States)

    Payne, Russell; Baccon, Jennifer; Dossett, John; Scollard, David; Byler, Debra; Patel, Akshal; Harbaugh, Kimberly

    2015-11-01

    Hansen's disease, or leprosy, is a chronic infectious disease with many manifestations. Though still a major health concern and leading cause of peripheral neuropathy in the developing world, it is rare in the United States, with only about 150 cases reported each year. Nevertheless, it is imperative that neurosurgeons consider it in the differential diagnosis of neuropathy. The causative organism is Mycobacterium leprae, which infects and damages Schwann cells in the peripheral nervous system, leading first to sensory and then to motor deficits. A rare presentation of Hansen's disease is pure neuritic leprosy. It is characterized by nerve involvement without the characteristic cutaneous stigmata. The authors of this report describe a case of pure neuritic leprosy presenting as ulnar nerve neuropathy with corresponding radiographic, electrodiagnostic, and histopathological data. This 11-year-old, otherwise healthy male presented with progressive right-hand weakness and numbness with no cutaneous abnormalities. Physical examination and electrodiagnostic testing revealed findings consistent with a severe ulnar neuropathy at the elbow. Magnetic resonance imaging revealed diffuse thickening and enhancement of the ulnar nerve and narrowing at the cubital tunnel. The patient underwent ulnar nerve decompression with biopsy. Pathology revealed acid-fast organisms within the nerve, which was pathognomonic for Hansen's disease. He was started on antibiotic therapy, and on follow-up he had improved strength and sensation in the ulnar nerve distribution. Pure neuritic leprosy, though rare in the United States, should be considered in the differential diagnosis of those presenting with peripheral neuropathy and a history of travel to leprosy-endemic areas. The long incubation period of M. leprae, the ability of leprosy to mimic other conditions, and the low sensitivity of serological tests make clinical, electrodiagnostic, and radiographic evaluation necessary for diagnosis

  16. Angular mining conveyor

    Energy Technology Data Exchange (ETDEWEB)

    Sender, A; Mura, A; Liduchowski, L; Zok, P; Skolik, W; Szyngiel, S; Rojek, H; Gajda, B; Major, M; Stanislawski, P; Sliwiok, H; Sikora, J

    1988-10-19

    Angular mining conveyor provided with a drag chain extending along the axis of its path of movement, and a corner member, inside which the drag chain is led in a forced way, characterized in that the drag chain, where its path curves around the corner member, is located by supporting of the vertical links of the chain along the required curved section of the conveyor path around said corner member, and the supporting line of the links is so chosen, that, within the said curved section of the conveyor path, a space is maintained between the vertical end surface of the scrapers and the outer curved surface of the radially inner side wall of a corner trough associated with the corner member, through which corner trough the scrapers pass. 10 figs.

  17. Viscous damping of toroidal angular momentum in tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Stacey, W. M. [Georgia Tech Fusion Research Center, Atlanta, Georgia 30332 (United States)

    2014-09-15

    The Braginskii viscous stress tensor formalism was generalized to accommodate non-axisymmetric 3D magnetic fields in general toroidal flux surface geometry in order to provide a representation for the viscous damping of toroidal rotation in tokamaks arising from various “neoclassical toroidal viscosity” mechanisms. In the process, it was verified that the parallel viscosity contribution to damping toroidal angular momentum still vanishes even in the presence of toroidal asymmetries, unless there are 3D radial magnetic fields.

  18. Stroke Chameleons Manifesting as Distinct Radial Neuropathies: Expertise Can Hasten the Diagnosis

    Directory of Open Access Journals (Sweden)

    Fabrício Diniz de Lima

    2017-12-01

    Full Text Available Objective: Stroke chameleons encompass an atypical group of syndromes that do not initially appear to be cerebrovascular accidents. The objective of this study was to report patients with different lesions of central origin clinically presenting as wrist drop and with a semiology similar to that produced by peripheral lesions of the radial nerve at different topographical levels. Methods: This is a case series study of patients presenting with wrist drop during the acute phase of stroke who were assessed by clinical examination and CT and MRI brain scans. Results: Three cases presenting as monoparesis were evaluated. In all patients, the MRI revealed restricted diffusion in the pre- and post-central gyrus. Electromyography showed that the functionality of the radial, median, and ulnar nerves were intact in all three cases. The monoparesis resolved completely within 1 month of rehabilitation therapy, and no evidence of recurrent or new events was reported during the 6-month follow-up after stenting. Conclusion: The central message of this study is that when acute onset symptoms are present in a relatively old patient with vascular risk factors, stroke should be considered as the possible aetiology until proven otherwise, and the appropriate steps should be taken to avoid a delay in the treatment and to improve outcomes.

  19. Plasmonic rainbow rings induced by white radial polarization.

    Science.gov (United States)

    Lan, Tzu-Hsiang; Chung, Yi-Kuan; Li, Jie-En; Tien, Chung-Hao

    2012-04-01

    This Letter presents a scheme to embed both angular/spectral surface plasmon resonance (SPR) in a unique far-field rainbow feature by tightly focusing (effective NA=1.45) a polychromatic radially polarized beam on an Au (20 nm)/SiO2 (500 nm)/Au (20 nm) sandwich structure. Without the need for angular or spectral scanning, the virtual spectral probe snapshots a wide operation range (n=1-1.42; λ=400-700 nm) of SPR excitation in a locally nanosized region. Combined with the high-speed spectral analysis, a proof-of-concept scenario was given by monitoring the NaCl liquid concentration change in real time. The proposed scheme will certainly has a promising impact on the development of objective-based SPR sensor and biometric studies due to its rapidity and versatility.

  20. Vertical, radial and drag force analysis of superconducting magnetic bearings

    International Nuclear Information System (INIS)

    Cansiz, Ahmet

    2009-01-01

    The behavior of the force between a permanent magnet (PM) and a high temperature superconductor (HTS) was tested with the frozen-image model based on flux pinning. It was found that the associated dipole moment assumptions of the method of the frozen image underestimate the force somewhat; thus a quadrupole moment analysis is proposed. The radial and drag forces associated with the rotation of the PM levitated above the HTS were measured by using a force transducer and by means of a cantilevered beam technique. The radial force was found not to be dependent on the radial direction, and the least radial force was found to be periodic with an angular displacement during the slow rotation of the PM relative to the HTS. The periodicity behavior of the force is attributed to the geometric eccentricity from the magnetization distribution of the PM and HTS. The drag force associated with the torsional stiffness of the levitated PM during the low and high rotational speeds was incorporated with the data from the literature.

  1. Effect of fascicle composition on ulnar to musculocutaneous nerve transfer (Oberlin transfer) in neonatal brachial plexus palsy.

    Science.gov (United States)

    Smith, Brandon W; Chulski, Nicholas J; Little, Ann A; Chang, Kate W C; Yang, Lynda J S

    2018-06-01

    OBJECTIVE Neonatal brachial plexus palsy (NBPP) continues to be a problematic occurrence impacting approximately 1.5 per 1000 live births in the United States, with 10%-40% of these infants experiencing permanent disability. These children lose elbow flexion, and one surgical option for recovering it is the Oberlin transfer. Published data support the use of the ulnar nerve fascicle that innervates the flexor carpi ulnaris as the donor nerve in adults, but no analogous published data exist for infants. This study investigated the association of ulnar nerve fascicle choice with functional elbow flexion outcome in NBPP. METHODS The authors conducted a retrospective study of 13 cases in which infants underwent ulnar to musculocutaneous nerve transfer for NBPP at a single institution. They collected data on patient demographics, clinical characteristics, active range of motion (AROM), and intraoperative neuromonitoring (IONM) (using 4 ulnar nerve index muscles). Standard statistical analysis compared pre- and postoperative motor function improvement between specific fascicle transfer (1-2 muscles for either wrist flexion or hand intrinsics) and nonspecific fascicle transfer (> 2 muscles for wrist flexion and hand intrinsics) groups. RESULTS The patients' average age at initial clinic visit was 2.9 months, and their average age at surgical intervention was 7.4 months. All NBPPs were unilateral; the majority of patients were female (61%), were Caucasian (69%), had right-sided NBPP (61%), and had Narakas grade I or II injuries (54%). IONM recordings for the fascicular dissection revealed a donor fascicle with nonspecific innervation in 6 (46%) infants and specific innervation in the remaining 7 (54%) patients. At 6-month follow-up, the AROM improvement in elbow flexion in adduction was 38° in the specific fascicle transfer group versus 36° in the nonspecific fascicle transfer group, with no statistically significant difference (p = 0.93). CONCLUSIONS Both specific and

  2. Impact of Open Reduction on Surgical Strategies for Missed Monteggia Fracture in Children.

    Science.gov (United States)

    Park, Hoon; Park, Kwang Won; Park, Kun Bo; Kim, Hyun Woo; Eom, Nam Kyu; Lee, Dong Hoon

    2017-07-01

    The aims of this study were to review our cases of missed Monteggia fracture treated by open reduction of the radial head with or without ulnar osteotomy and to investigate the indications for open reduction alone in surgical treatment of missed Monteggia fracture. We retrospectively reviewed 22 patients who presented with missed Monteggia fracture. The patients' mean age at the time of surgery was 7.6 years. The mean interval from injury to surgery was 16.1 months. The surgical procedure consisted of open reduction of the radiocapitellar joint followed by ulnar osteotomy without reconstruction of the annular ligament. The mean period of follow-up was 3.8 years. Radiographic assessment was performed for the maximum ulnar bow (MUB) and the location of the MUB. Clinical results were evaluated with the Mayo Elbow Performance Index and Kim's scores. Five patients underwent open reduction alone, and 17 patients underwent open reduction and ulnar osteotomy. When the MUB was less than 4 mm and the location of the MUB was in the distal 40% of the ulna, we could achieve reduction of the radial head without ulnar osteotomy. The radial head was maintained in a completely reduced position in 21 patients and was dislocated in one patient at final follow-up. Open reduction alone can be an attractive surgical option in select patients with missed Monteggia fracture with minimal bowing of the distal ulna. However, ulnar osteotomy should be considered in patients with a definite ulnar deformity. © Copyright: Yonsei University College of Medicine 2017

  3. Comparison between open and arthroscopic-assisted foveal triangular fibrocartilage complex repair for post-traumatic distal radio-ulnar joint instability.

    Science.gov (United States)

    Luchetti, R; Atzei, A; Cozzolino, R; Fairplay, T; Badur, N

    2014-10-01

    The aim of this study was to assess the objective and subjective functional outcomes after foveal reattachment of proximal or complete ulnar-sided triangular fibrocartilage complex lesions by two surgical procedures: an open technique or an arthroscopically assisted repair. The study was done prospectively on 49 wrists affected by post-traumatic distal radio-ulnar joint instability. Twenty-four patients were treated with the open technique (Group 1) and 25 by the arthroscopically assisted technique (Group 2). Magnetic resonance imaging demonstrated a clear foveal detachment of the triangular fibrocartilage complex in 67% of the cases. Arthroscopy showed a positive ulnar-sided detachment of the triangular fibrocartilage complex (positive hook test) in all cases. Distal radio-ulnar joint stability was obtained in all but five patients at a mean follow-up of 6 months. Both groups had improvement of all parameters with significant differences in wrist pain scores, Mayo wrist score, Disability of the Arm, Shoulder and Hand questionnaire and Patient-Rated Wrist/Hand Evaluation questionnaire scores. There were no significant post-operative differences between the two groups in the outcome parameters except for the Disability of the Arm Shoulder and Hand questionnaire score, which was significantly better in Group 2 (p < 0.001). © The Author(s) 2013.

  4. Photofragment angular momentum distribution beyond the axial recoil approximation: Predissociation

    International Nuclear Information System (INIS)

    Kuznetsov, Vladislav V.; Vasyutinskii, Oleg S.

    2007-01-01

    We present the quantum mechanical expressions for the angular momentum distribution of the photofragments produced in slow predissociation. The paper is based on our recent theoretical treatment [J. Chem. Phys. 123, 034307 (2005)] of the recoil angle dependence of the photofragment multipole moments which explicitly treat the role of molecular axis rotation on the electronic angular momentum polarization of the fragments. The electronic wave function of the molecule was used in the adiabatic body frame representation. The rigorous expressions for the fragment state multipoles which have been explicitly derived from the scattering wave function formalism have been used for the case of slow predissociation where a molecule lives in the excited quasibound state much longer than a rotation period. Possible radial nonadiabatic interactions were taken into consideration. The optical excitation of a single rotational branch and the broadband incoherent excitation of all possible rotational branches have been analyzed in detail. The angular momentum polarization of the photofragments has been treated in the high-J limit. The polarization of the photofragment angular momenta predicted by the theory depends on photodissociation mechanism and can in many cases be significant

  5. Radiologic examination and measurement of the wrist and distal radio-ulnar joint

    International Nuclear Information System (INIS)

    Toernvall, A.H.; Ekenstam, F. af; Hagert, C.G.; Irstam, L.; Sahlgrenska Sjukhuset, Goeteborg; Uppsala Univ.

    1986-01-01

    Following fractures of the distal radius, a relatively high incidence of complications is caused by malalignment in the distal radio-ulnar (DRU) joint; recent anatomic and clinical investigations have shown a congruity of that joint to be of significant importance for restoring the function of the wrist. The radius forms a moderately arched bone, which moves around the ulna in pronation and supination. Biomechanically, the ulna may be regarded as the pillar around which the radius moves. In an anatomic investigation of 5 arm specimens, we have shown that the maximum cartilage contact in the DRU joint between the ulna head and the distal radius occurs in the neutral rotation position. A proposed routine examination method of the wrist and forearm includes a true antero-posterior and a lateral projection of the radius and the ulna, performed with the forearm and wrist in a neutral rotation, a neutral wrist deviation and with the elbow angled 90 degrees. Such an examination implies a standardized and reproducible method. In a radioanatomic investigation, a series of 50 healthy wrists and forearms were examined. A simple measuring technique is presented, applicable to the DRU joint and wrist favouring the ulna as the bone through which a reproducible long axis of the forearm/wrist may be drawn. It is suggested that the length of the radius should be judged relative to the ulna. Ulnar head inclination and radio-ulnar angle are new concepts, being major characteristics of the DRU joint. These angles of the right and left wrist were equal and no difference was found between the sexes. Minor alterations of the distal radius may be revealed when estimating these angles. (orig.)

  6. Evolution of rotating stars. III. Predicted surface rotation velocities for stars which conserve total angular momentum

    International Nuclear Information System (INIS)

    Endal, A.S.; Sofia, S.

    1979-01-01

    Predicted surface rotation velocities are presented for Population I stars at 10, 7, 5, 3, and 1.5M/sub sun/. The surface velocities have been computed for three different cases of angular momentum redistribution: no radial redistribution (rotation on decoupled shells), complete redistribution (rigid-body rotation), and partial redistribution as predicted by detailed consideration of circulation currents in rotation stars. The velocities for these cases are compared to each other and to observed stellar rotation rates (upsilon sin i).Near the main sequence, rotational effects can substantially reduce the moment of inertia of a star, so nonrotating models consistently underestimate the expected velocities for evolving stars. The magnitude of these effects is sufficient to explain the large numbers of Be stars and, perhaps, to explain the bimodal distribution of velocities observed for the O stars.On the red giant branch, angular momentum redistribution reduces the surface velocity by a factor of 2 or more, relative to the velocity expected for no radial redistribution. This removes the discrepancy between predicted and observed rotation rates for the K giants and makes it unlikely that these stars lose significant amounts of angular momentum by stellar winds. Our calculations indicate that improved observations (by the Fourier-transform technique) of the red giants in the Hyades cluster can be used to determine how angular momentum is redistributed by convection

  7. Pisotriquetral joint disorders: an under-recognized cause of ulnar side wrist pain

    Energy Technology Data Exchange (ETDEWEB)

    Moraux, A. [Hopital Roger Salengro, Service d' Imagerie Musculo-Squelettique, Centre de Consultation de l' Appareil Locomoteur, CHRU Lille (France); Imagerie Medicale Jacquemars Gielee, Lille (France); Lefebvre, G.; Pansini, V.; Aucourt, J.; Vandenbussche, L.; Cotten, A. [Hopital Roger Salengro, Service d' Imagerie Musculo-Squelettique, Centre de Consultation de l' Appareil Locomoteur, CHRU Lille (France); Demondion, X. [Hopital Roger Salengro, Service d' Imagerie Musculo-Squelettique, Centre de Consultation de l' Appareil Locomoteur, CHRU Lille (France); Pole Recherche Faculte de Medecine de Lille, Laboratoire d' Anatomie, Lille (France)

    2014-06-15

    Pisotriquetral joint disorders are often under-recognized in routine clinical practice. They nevertheless represent a significant cause of ulnar side wrist pain. The aim of this article is to present the main disorders of this joint and discuss the different imaging modalities that can be useful for its assessment. (orig.)

  8. Injuries to the Collateral Ligaments of the Metacarpophalangeal Joint of the Thumb, Including Simultaneous Combined Thumb Ulnar and Radial Collateral Ligament Injuries, in National Football League Athletes.

    Science.gov (United States)

    Werner, Brian C; Belkin, Nicole S; Kennelly, Steve; Weiss, Leigh; Barnes, Ronnie P; Rodeo, Scott A; Warren, Russell F; Hotchkiss, Robert N

    2017-01-01

    Thumb collateral ligament injuries occur frequently in the National Football League (NFL). In the general population or in recreational athletes, pure metacarpophalangeal (MCP) abduction or adduction mechanisms yield isolated ulnar collateral ligament (UCL) and radial collateral ligament (RCL) tears, respectively, while NFL athletes may sustain combined mechanism injury patterns. To evaluate the incidence of simultaneous combined thumb UCL and RCL tears among all thumb MCP collateral ligament injuries in NFL athletes on a single team. Case series; Level of evidence, 4. A retrospective review of all thumb injuries on a single NFL team from 1991 to 2014 was performed. All players with a thumb MCP collateral ligament injury were included. Collateral ligament injuries were confirmed by review of both physical examination findings and magnetic resonance imaging. Player demographics, surgical details, and return-to-play data were obtained from the team electronic medical record and surgeons' records. A total of 36 thumbs in 32 NFL players were included in the study, yielding an incidence of 1.6 thumb MCP collateral ligament injuries per year on a single NFL team. Of these, 9 thumbs (25%) had a simultaneous combined UCL and RCL tear injury pattern confirmed on both physical examination and MRI. The remaining 27 thumbs (75%) were isolated UCL injuries. All combined UCL/RCL injuries required surgery due to dysfunction from instability; 63.0% of isolated UCL injuries required surgical repair ( P = .032) due to continued pain and dysfunction from instability. Repair, when required, was delayed until the end of the season. All players with combined UCL/RCL injuries and isolated UCL injuries returned to play professional football the following season. Simultaneous combined thumb UCL and RCL tear is a previously undescribed injury pattern that occurred in 25% of thumb MCP collateral ligament injuries on a single NFL team over a 23-year period. All players with combined thumb UCL

  9. Completed Ulnar Shaft Stress Fracture in a Fast-Pitch Softball Pitcher.

    Science.gov (United States)

    Wiltfong, Roger E; Carruthers, Katherine H; Popp, James E

    2017-03-01

    Stress fractures of the upper extremity have been previously described in the literature, yet reports of isolated injury to the ulna diaphysis or olecranon are rare. The authors describe a case involving an 18-year-old fast-pitch softball pitcher. She presented with a long history of elbow and forearm pain, which was exacerbated during a long weekend of pitching. Her initial physician diagnosed her as having forearm tendinitis. She was treated with nonsurgical means including rest, anti-inflammatory medications, therapy, and kinesiology taping. She resumed pitching when allowed and subsequently had an acute event immediately ceasing pitching. She presented to an urgent care clinic that evening and was diagnosed as having a complete ulnar shaft fracture subsequently needing surgical management. This case illustrates the need for a high degree of suspicion for ulnar stress fractures in fast-pitch soft-ball pitchers with an insidious onset of unilateral forearm pain. Through early identification and intervention, physicians may be able to reduce the risk of injury progression and possibly eliminate the need for surgical management. [Orthopedics. 2017; 40(2):e360-e362.]. Copyright 2016, SLACK Incorporated.

  10. Investigation of radialization and rerouting of the extensor digiti minimi (EDM) in the abduction deformity of the little finger: a cadaver study.

    Science.gov (United States)

    van Aaken, Jan; Zhu, Jin; Fasel, Jean H D; Beaulieu, Jean-Yves

    2011-06-01

    One of several operations to correct abduction deformity of the little finger, (Wartenberg's sign) in ulnar nerve palsy, is a combined procedure that radializes the extensor digiti minimi (EDM) at the level of the fifth metacarpophalangeal (MCP) joint and reroutes it from the fifth to fourth extensor compartment. This cadaveric study was designed to investigate the impact of both elements on adduction. Anatomy of the little finger extensor apparatus was studied in 16 freshly frozen cadaver hands sectioned at mid forearm. We observed little finger motion after different modifications of the EDM. We tested the effect of a rerouting maneuver by pulling on the EDM, as well as radialization of the EDM alone and in combination with rerouting. The EDM was present in all cases. Little finger extensor digitorum communis (EDC(V)) was missing in two cadavers. In no case was adduction created by rerouting the EDM to the fourth compartment. Radialization of the EDM corrected the abduction deformity beyond the axis of abduction/adduction of the fifth MCP joint in 13 cases and only up to it in three cases. In one of the three with limited correction, a rerouting maneuver allowed for further adduction. The key to correct abduction deformity of the little finger is radialization of the EDM, which can be done through a solitary incision at the level of the MCP joint. Rerouting alone does not correct the abduction deformity, and in combination with radialization it does not predictably enhance the correction.

  11. Evaluation of anatomy and variations of superficial palmar arch and upper extremity arteries with CT angiography.

    Science.gov (United States)

    Kaplanoglu, Hatice; Beton, Osman

    2017-04-01

    To evaluate the abnormalities and variations of the arterial system of upper extremities and superficial palmar arch with computed tomography angiography and to guide the clinician during this procedure. A total of 156 upper extremities of 78 cases were retrospectively analyzed using computed tomography angiography. The study was approved by the local ethics committee of the hospital. From the analysis of the computed tomography angiography images, the following information was recorded; the diameters and abnormalities of radial, ulnar and brachial arteries in both upper extremities, the presence of atherosclerotic changes or stenosis in these arteries, whether the superficial palmar arch was complete or incomplete, and arterial dominance. Also, the computed tomography angiography classification of superficial palmar arch distribution and anatomic configuration was performed. The mean baseline diameters of the radial, ulnar and brachial arteries of the cases were; 2.8 ± 0.6, 2.5 ± 0.7, and 4.7 ± 0.6 mm, respectively. A complete superficial palmar arch was observed in 69.2 % of the right hands and 70.5 % of the left hands. For the superficial palmar arches on the right side, the radial artery was dominant in two and the ulnar artery was dominant in 47 with the remaining showing codominance. On the left side, the radial artery was dominant in one hand, with the ulnar artery being dominant in 49 cases, and in 28 cases, there was codominance. In the superficial palmar arch classification, four of the arches (A-D) were defined as complete and the remaining three (E-G) as incomplete. The current study clarified different variations in palmar circulation and forearm arteries to aid the surgeon during trans-radial or trans-ulnar catheterization, hemodialysis, or coronary artery bypass grafting.

  12. Revolution evolution: tracing angular momentum during star and planetary system formation

    Science.gov (United States)

    Davies, Claire Louise

    2015-04-01

    disc to expand. I used spatially resolved submillimetre detections of the dust and gas components of protoplanetary discs, gathered from the literature, to measure the radial extent of discs around low-mass pre-main sequence stars of ∼ 1-10 Myr and probe their viscous evolution. I find no clear observational evidence for the radial expansion of the dust component. However, I find tentative evidence for the expansion ofthe gas component. This suggests that the evolution of the gas and dust components of protoplanetary discs are likely governed by different astrophysical processes. Observations of jets and outflows emanating from protostars and pre-main sequence stars highlight that it may also be possible to remove angular momentum from the circumstellar material. Using the sample of spatially resolved protoplanetary discs, I find no evidence for angular momentum removal during disc evolution. I also use the spatially resolved debris discs from the Submillimetre Common-User Bolometer Array-2 Observations of Nearby Stars survey to constrain the amount of angular momentum retained within planetary systems. This sample is compared to the protoplanetary disc angular momenta and to the angular momentum contained within pre-stellar cores. I find that significant quantities of angular momentum must be removed during disc formation and disc dispersal. This likely occurs via magnetic braking during the formation of the disc, via the launching of a disc or photo-evaporative wind, and/or via ejection of planetary material following dynamical interactions.

  13. Some energy and angular characteristics of electrons in electromagnetic cascades in air

    Science.gov (United States)

    Stanev, T.; Vankov, Kh.; Petrov, S.; Elbert, J. W.

    The angular distribution of electrons with threshold energies of 20 MeV (the lowest energy at which electrons radiate Cerenkov photons in the air) are considered. The results are based on Monte Carlo calculations of the development of electromagnetic cascades. A set of showers with energy thresholds equals 20 MeV and primary photon energies equals 10, 20, 30, and 100 GeV is simulated. Information about the particle properties (energy, angle, and radial displacement) is provided at each radiation length of depth. The electrons are at much smaller angles to the shower axis than were those of Messel and Crawford (1970); this explains the discrepancy in angular distribution of Cerenkov light in air between the two.

  14. Sonographic measurements of the ulnar nerve at the elbow with different degrees of elbow flexion.

    Science.gov (United States)

    Patel, Prutha; Norbury, John W; Fang, Xiangming

    2014-05-01

    To determine whether there were differences in the cross-sectional area (CSA) and the flattening ratio of the normative ulnar nerve as it passes between the medial epicondyle and the olecranon at 30° of elbow flexion versus 90° of elbow flexion. Bilateral upper extremities of normal healthy adult volunteers were evaluated with ultrasound. The CSA and the flattening ratio of the ulnar nerve at the elbow as it passes between the medial epicondyle and the olecranon were measured, with the elbow flexed at 30° and at 90°, by 2 operators with varying ultrasound scanning experience by using ellipse and direct tracing methods. The results from the 2 different angles of elbow flexion were compared for each individual operator. Finally, intraclass correlations for absolute agreement and consistency between the 2 raters were calculated. An outpatient clinic room at a regional rehabilitation center. Twenty-five normal healthy adult volunteers. The mean CSA and the mean flattening ratio of the ulnar nerve at 30° of elbow flexion and at 90° of elbow flexion. First, for the ellipse method, the mean CSA of the ulnar nerve at 90° (9.93 mm(2)) was slightly larger than at 30° (9.77 mm(2)) for rater 1. However, for rater 2, the mean CSA of the ulnar nerve at 90° (6.80 mm(2)) was slightly smaller than at 30° (7.08 mm(2)). This was found to be statistically insignificant when using a matched pairs t test and the Wilcoxon signed-rank test, with a significance level of .05. Similarly, the difference between the right side and the left side was not statistically significant. The intraclass correlations for absolute agreement between the 2 raters were not very high due to different measurement locations, but the intraclass correlations for consistency were high. Second, for the direct tracing method, the mean CSA at 90° (7.26 mm(2)) was slightly lower than at 30° (7.48 mm(2)). This was found to be statistically nonsignificant when using the matched pairs t test and the

  15. Uniqueness for the inverse backscattering problem for angularly controlled potentials

    International Nuclear Information System (INIS)

    Rakesh; Uhlmann, Gunther

    2014-01-01

    We consider the problem of recovering a smooth, compactly supported potential on R 3 from its backscattering data. We show that if two such potentials have the same backscattering data and the difference of the two potentials has controlled angular derivatives, then the two potentials are identical. In particular, if two potentials differ by a finite linear combination of spherical harmonics with radial coefficients and have the same backscattering data then the two potentials are identical. (paper)

  16. Fortalecimento dos músculos da mão em pacientes submetidos a neurorrafia do ulnar com videogame/Strengthening of hand muscles in patients submitted to neurorrhaphy of ulnar nerve through the videogame

    Directory of Open Access Journals (Sweden)

    Bruno Goto Kimura

    2017-09-01

    Full Text Available O objetivo deste trabalho foi verificar se o fortalecimento muscular com o uso do videogame E-link promove aumento da força para os músculos da mão em pacientes com lesão de nervo ulnar. Resultados: Comparando a média das forças de preensão e pinças antes e após o fortalecimento, houve um aumento de força para todos os movimentos. Na força de preensão palmar houve em média um aumento de 50%, na pinça polpa-lateral houve na média um aumento de 24%, na pinça polpa-trípode a média foi de 8% de ganho de força e na pinça polpa-polpa a média foi de 10% de aumento na força. Discussão: A realidade virtual tem sido utilizada atualmente para modificar as terapias tradicionais com o intuito de aumentar a motivação no tratamento, como forma de entretenimento para o paciente, aumentando assim o seu desempenho na realização dos exercícios. Conclusão: Este estudo demonstrou houve ganho de força de preensão e das pinças, após o programa de fortalecimento com o uso do videogame para os músculos intrínsecos e extrínsecos da mão de pacientes após neurorrafia do nervo ulnar. AbstractThe objective of this study was to verify if muscle strengthening using the E-link videogame promotes increased strength for the hand muscles in patients with ulnar nerve injury. Results: Comparing the average grip and pinch strength before and after strengthening, there was an increase in strength for all movements. In the palmar grip strength there was an increase of 50%, in key pinch there was an increase of 24%, in tripod pinch the average was 8% and tip-to-tip pinch the increase was 10% in strength. Discussion: Virtual reality has been use most frequently to modify traditional therapies in order to improve treatment motivation as a form of entertainment for the patient, thus increasing their performance in performing the exercises. Conclusion: This study demonstrated an increase in grip and pinch strength. After the program of strengthening

  17. Ulnar nerve paralysis after forearm bone fracture

    Directory of Open Access Journals (Sweden)

    Carlos Roberto Schwartsmann

    2016-08-01

    Full Text Available ABSTRACT Paralysis or nerve injury associated with fractures of forearm bones fracture is rare and is more common in exposed fractures with large soft-tissue injuries. Ulnar nerve paralysis is a rare condition associated with closed fractures of the forearm. In most cases, the cause of paralysis is nerve contusion, which evolves with neuropraxia. However, nerve lacerations and entrapment at the fracture site always need to be borne in mind. This becomes more important when neuropraxia appears or worsens after reduction of a closed fracture of the forearm has been completed. The importance of diagnosing this injury and differentiating its features lies in the fact that, depending on the type of lesion, different types of management will be chosen.

  18. Cooling modifies mixed median and ulnar palmar studies in carpal tunnel syndrome Influência do resfriamento nos parâmetros de condução nervosa mista do mediano e ulnar na síndrome do túnel do carpo

    Directory of Open Access Journals (Sweden)

    Rogério Gayer Machado de Araújo

    2007-09-01

    Full Text Available Temperature is an important and common variable that modifies nerve conduction study parameters in practice. Here we compare the effect of cooling on the mixed palmar median to ulnar negative peak-latency difference (PMU in electrodiagnosis of carpal tunnel syndrome (CTS. Controls were 22 subjects (19 women, mean age 42.1 years, 44 hands. Patients were diagnosed with mild symptomatic CTS (25 women, mean age 46.6 years, 34 hands. PMU was obtained at the usual temperature, >32°C, and after wrist/hand cooling to Temperatura é uma variável comum e importante que modifica os parâmetros de condução nervosa na prática eletrodiagnóstica. Neste trabalho nós estudamos o efeito do esfriamento na diferença de latências palmares entre o nervo mediano e ulnar (PMU, segmento palma-pulso, utilizada rotineiramente para o eletrodiagnóstico da síndrome do túnel do carpo (STC. Foram estudados 22 controles (19 mulheres, média de idade 42,1 anos, 44 mãos e 25 pacientes (25 mulheres, média de idade 46,6 anos, 34 mãos com diagnóstico de STC leve. PMU foi obtida em temperatura usual (>32°C, e após resfriamento de mão/pulso em água com gelo (<27°C. Após o resfriamento houve aumento significativo na PMU e na latência mista palmar do nervo ulnar nos pacientes quando comparados aos controles. Nós concluímos que o resfriamento modifica significativamente a PMU e propomos que as latências obtidas em nervos submetidos à compressão reagem de maneira mais acentuada ao frio e isso poderia ser uma arma útil para o eletrodiagnóstico da STC incipiente. Da mesma forma, houve reação mais acentuada ao frio no estudo da latência mista palmar do nervo ulnar nos pacientes mas não nos controles, que poderia levantar a hipótese de compressão subclínica do nervo ulnar.

  19. Transverse spin in the scattering of focused radially and azimuthally polarized vector beams

    Science.gov (United States)

    Singh, Ankit Kumar; Saha, Sudipta; Gupta, Subhasish Dutta; Ghosh, Nirmalya

    2018-04-01

    We study the effect of focusing of the radially and azimuthally polarized vector beams on the spin angular momentum (SAM) density and Poynting vector of scattered waves from a Mie particle. Remarkably, the study reveals that the SAM density of the scattered field is solely transverse in nature for radially and azimuthally polarized incident vector beams; however, the Poynting vector shows the usual longitudinal character. We also demonstrate that the transverse SAM density can further be tuned with wavelength and focusing of the incident beam by exploiting the interference of different scattering modes. These results may stimulate further experimental techniques to detect the transverse spin and Belinfante's spin-momentum densities.

  20. The spinning disc: studying radial acceleration and its damping process with smartphone acceleration sensors

    Science.gov (United States)

    Hochberg, K.; Gröber, S.; Kuhn, J.; Müller, A.

    2014-03-01

    Here, we show the possibility of analysing circular motion and acceleration using the acceleration sensors of smartphones. For instance, the known linear dependence of the radial acceleration on the distance to the centre (a constant angular frequency) can be shown using multiple smartphones attached to a revolving disc. As a second example, the decrease of the radial acceleration and the rotation frequency due to friction can be measured and fitted with a quadratic function, in accordance with theory. Finally, because the disc is not set up exactly horizontal, each smartphone measures a component of the gravitational acceleration that adds to the radial acceleration during one half of the period and subtracts from the radial acceleration during the other half. Hence, every graph shows a small modulation, which can be used to determine the rotation frequency, thus converting a ‘nuisance effect’ into a source of useful information, making additional measurements with stopwatches or the like unnecessary.

  1. Elbow joint instability

    DEFF Research Database (Denmark)

    Olsen, Bo Sanderhoff; Henriksen, M G; Søjbjerg, Jens Ole

    1994-01-01

    The effect of simultaneous ulnar and radial collateral ligament division on the kinematics of the elbow joint is studied in a cadaveric model. Severance of the anterior part of the ulnar collateral ligament and the annular ligament led to significant elbow joint instability in valgus and varus...

  2. OSTEOID OSTEOMA OF THE HAMATE AS A CAUSE OF COMPRESSION NEUROPATHY OF THE ULNAR NERVE IN GUYON CANAL (CASE REPORT

    Directory of Open Access Journals (Sweden)

    O. M. Semenkin

    2017-01-01

    Full Text Available Osteoid  osteoma of the wrist bones is rare and its diagnostics is complicated. A clinical case of the surgical treatment of the patient with osteoid osteoma is presented. The clinical manifestations included  pain, extensors  tenosynovitis and neuropathy of the ulnar nerve in guyon’s canal. The diagnosis was confirmed by computer tomography, ultrasonography and electromyography. Partial resection of the hamate including pathology area, and mobilization of the ulnar nerve in the wrist enabled authors  to obtain a good functional outcome.

  3. Anatomical variants of lister's tubercle; A new morphological classification based on magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wan Ying; Chong, Le Roy [Dept. of Radiology, Changi General Hospital, Singapore (Singapore)

    2017-11-15

    Lister's tubercle is used as a standard anatomical landmark in hand surgery and arthroscopy procedures. In this study, we aimed to evaluate and propose a classification for anatomical variants of Lister's tubercle. Between September 2011 and July 2014, 360 MRI examinations for wrists performed using 1.5T scanners in a single institution were retrospectively evaluated. The prevalence of anatomical variants of Lister's tubercle based on the heights and morphology of its radial and ulnar peaks was assessed. These were classified into three distinct types: radial peak larger than ulnar peak (Type 1), similar radial and ulnar peaks (Type 2) and ulnar peak larger than radial peak (Type 3). Each type was further divided into 2 subtypes (A and B) based on the morphology of the peaks. The proportions of Type 1, Type 2, and Type 3 variants in the study population were 69.2, 21.4, and 9.5%, respectively. For the subtypes, the Type 1A variant was the most common (41.4%) and conformed to the classical appearance of Lister's tubercle; whereas, Type 3A and 3B variants were rare configurations (6.4% and 3.1%, respectively) wherein the extensor pollicis longus tendon coursed along the radial aspect of Lister's tubercle. Anatomical variations of Lister's tubercle have potential clinical implications for certain pathological conditions and pre-procedural planning. The proposed classification system facilitates a better understanding of these anatomical variations and easier identification of at-risk and rare variants.

  4. Congenital Deficiency of Distal Ulna and Dislocation of the Radial Head Treated by Single Bone Forearm Procedure

    Directory of Open Access Journals (Sweden)

    Paragjyoti Gogoi

    2014-01-01

    Full Text Available Congenital deficiency of part of distal ulna affecting the distal radio-ulnar joint is a rare disorder. It is even rarer to find the association of proximal radio-ulnar joint dislocation along with distal ulnar deficiency. This type of congenital forearm anomaly is difficult to treat. Conversion to a single bone forearm in the expense of pronation-supination movement is a viable option. By doing so the elbow and wrist can be stabilized; however movement is possible in only one plane. We are describing here a girl of 8 years having proximal radio-ulnar joint dislocation along with deficiency of distal ulna treated by converting into a single bone forearm.

  5. Clarification of Eponymous Anatomical Terminology: Structures Named After Dr Geoffrey V. Osborne That Compress the Ulnar Nerve at the Elbow.

    Science.gov (United States)

    Wali, Arvin R; Gabel, Brandon; Mitwalli, Madhawi; Tubbs, R Shane; Brown, Justin M

    2017-05-01

    In 1957, Dr Geoffrey Osborne described a structure between the medial epicondyle and the olecranon that placed excessive pressure on the ulnar nerve. Three terms associated with such structures have emerged: Osborne's band, Osborne's ligament, and Osborne's fascia. As anatomical language moves away from eponymous terminology for descriptive, consistent nomenclature, we find discrepancies in the use of anatomic terms. This review clarifies the definitions of the above 3 terms. We conducted an extensive electronic search via PubMed and Google Scholar to identify key anatomical and surgical texts that describe ulnar nerve compression at the elbow. We searched the following terms separately and in combination: "Osborne's band," "Osborne's ligament," and "Osborne's fascia." A total of 36 papers were included from 1957 to 2016. Osborne's band, Osborne's ligament, and Osborne's fascia were found to inconsistently describe the etiology of ulnar neuritis, referring either to the connective tissue between the 2 heads of the flexor carpi ulnaris muscle as described by Dr Osborne or to the anatomically distinct fibrous tissue between the olecranon process of the ulna and the medial epicondyle of the humerus. The use of eponymous terms to describe ulnar pathology of the elbow remains common, and although these terms allude to the rich history of surgical anatomy, these nonspecific descriptions lead to inconsistencies. As Osborne's band, Osborne's ligament, and Osborne's fascia are not used consistently across the literature, this research demonstrates the need for improved terminology to provide reliable interpretation of these terms among surgeons.

  6. Radiologic examination and measurement of the wrist and distal radio-ulnar joint. New aspects

    Energy Technology Data Exchange (ETDEWEB)

    Toernvall, A.H.; Ekenstam, F. af; Hagert, C.G.; Irstam, L.

    Following fractures of the distal radius, a relatively high incidence of complications is caused by malalignment in the distal radio-ulnar (DRU) joint; recent anatomic and clinical investigations have shown a congruity of that joint to be of significant importance for restoring the function of the wrist. The radius forms a moderately arched bone, which moves around the ulna in pronation and supination. Biomechanically, the ulna may be regarded as the pillar around which the radius moves. In an anatomic investigation of 5 arm specimens, we have shown that the maximum cartilage contact in the DRU joint between the ulna head and the distal radius occurs in the neutral rotation position. A proposed routine examination method of the wrist and forearm includes a true antero-posterior and a lateral projection of the radius and the ulna, performed with the forearm and wrist in a neutral rotation, a neutral wrist deviation and with the elbow angled 90 degrees. Such an examination implies a standardized and reproducible method. In a radioanatomic investigation, a series of 50 healthy wrists and forearms were examined. A simple measuring technique is presented, applicable to the DRU joint and wrist favouring the ulna as the bone through which a reproducible long axis of the forearm/wrist may be drawn. It is suggested that the length of the radius should be judged relative to the ulna. Ulnar head inclination and radio-ulnar angle are new concepts, being major characteristics of the DRU joint. These angles of the right and left wrist were equal and no difference was found between the sexes. Minor alterations of the distal radius may be revealed when estimating these angles.

  7. Sequences of extremal radially excited rotating black holes.

    Science.gov (United States)

    Blázquez-Salcedo, Jose Luis; Kunz, Jutta; Navarro-Lérida, Francisco; Radu, Eugen

    2014-01-10

    In the Einstein-Maxwell-Chern-Simons theory the extremal Reissner-Nordström solution is no longer the single extremal solution with vanishing angular momentum, when the Chern-Simons coupling constant reaches a critical value. Instead a whole sequence of rotating extremal J=0 solutions arises, labeled by the node number of the magnetic U(1) potential. Associated with the same near horizon solution, the mass of these radially excited extremal solutions converges to the mass of the extremal Reissner-Nordström solution. On the other hand, not all near horizon solutions are also realized as global solutions.

  8. Twistor theory and the energy-momentum and angular momentum of the gravitational field at spatial infinity

    International Nuclear Information System (INIS)

    Shaw, W.T.

    1983-01-01

    Penrose's 'quasi-local mass and angular momentum' is investigated for 2-surfaces near spatial infinity in both linearized theory on Minkowski space and full general relativity. It is shown that for space-times that are radially smooth of order one in the sense of Beig and Schmidt with asymptotically electric Weyl curvature, there exists a global concept of a twistor space at spatial infinity. Global conservation laws for the energy-momentum and angular momentum are obtained, and the ten conserved quantities are shown to be invariant under asymptotic coordinate transformations. The relation to other definitions is discussed briefly. (author)

  9. Narrow-band 1, 2, 3, 4, 8, 16 and 24 cycles/360o angular frequency filters

    Directory of Open Access Journals (Sweden)

    Simas M.L.B.

    2002-01-01

    Full Text Available We measured human frequency response functions for seven angular frequency filters whose test frequencies were centered at 1, 2, 3, 4, 8, 16 or 24 cycles/360º using a supra-threshold summation method. The seven functions of 17 experimental conditions each were measured nine times for five observers. For the arbitrarily selected filter phases, the maximum summation effect occurred at test frequency for filters at 1, 2, 3, 4 and 8 cycles/360º. For both 16 and 24 cycles/360º test frequencies, maximum summation occurred at the lower harmonics. These results allow us to conclude that there are narrow-band angular frequency filters operating somehow in the human visual system either through summation or inhibition of specific frequency ranges. Furthermore, as a general result, it appears that addition of higher angular frequencies to lower ones disturbs low angular frequency perception (i.e., 1, 2, 3 and 4 cycles/360º, whereas addition of lower harmonics to higher ones seems to improve detection of high angular frequency harmonics (i.e., 8, 16 and 24 cycles/360º. Finally, we discuss the possible involvement of coupled radial and angular frequency filters in face perception using an example where narrow-band low angular frequency filters could have a major role.

  10. The ARCS radial collimator

    International Nuclear Information System (INIS)

    Stone, M.B.; Abernathy, D.L.; Niedziela, J.L.; Overbay, M.A.

    2015-01-01

    We have designed, installed, and commissioned a scattered beam radial collimator for use at the ARCS Wide Angular Range Chopper Spectrometer at the Spallation Neutron Source. The collimator has been designed to work effectively for thermal and epithermal neutrons and with a range of sample environments. Other design considerations include the accommodation of working within a high vacuum environment and having the ability to quickly install and remove the collimator from the scattered beam. The collimator is composed of collimating blades (or septa). The septa are 12 micron thick Kapton foils coated on each side with 39 microns of enriched boron carbide ( 10 B 4 C with 10 B > 96%) in an ultra-high vacuum compatible binder. The collimator blades represent an additional 22 m 2 of surface area. In the article we present collimator's design and performance and methodologies for its effective use

  11. Monoaxial distraction of ulna to second metacarpal followed by single bone forearm in massive post infective radial bone loss

    Directory of Open Access Journals (Sweden)

    Jitendra N Pal

    2012-01-01

    Full Text Available Introduction: Radial bone loss associated with gross manus valgus deformity can be managed by open reduction internal fixation using intervening strut bone graft, callus distraction using ring or monoaxial fixator, and achieving union by distraction histogenesis. These methods are particularly suitable when bone loss is small. Single or staged procedure is described for congenital as well as in acquired extensive bone loss of radius. Distraction through radial proximal to distal segments, to achieve reduction of distal radio-ulnar joint (DRUJ, is also described in acquired cases. In the present series, functional results of distraction through ulna to 2 nd metacarpal is studied alongwith, functional status of hand, stability of wrist, level of patient′s satisfaction are also studied. Materials and Methods: 7 unilateral cases of radial loss (M = 5, F = 2 affecting 4 right hands of mean age 17 years (range 9 to 24 years were included in this study. They were treated by distracting through ulna to 2 nd metacarpal to achieve DRUJ alignment in first stage. Subsequently ulna was osteotomised and translated to distal stump of radius. It was then fixed to the distal radial remnant in 30° pronation in dominant and 30° supination non dominant hands. Results: Union was achieved in all cases associated with beneficial cross union of distal ulna. Hand functions improved near to normal, with fully corrected stable wrist joint, hypertrophied ulna and without recurrence. All of them had practically complete loss of forearm rotations, however patients were fully satisfied. Conclusion: This method is particularly suitable when associated with 6 cm or more radial bone loss. But when loss is small, sacrifice of one bone may not be justifiable.

  12. Rupture of the ulnar collateral ligament of the thumb ? a review

    OpenAIRE

    Mahajan, Mandhkani; Rhemrev, Steven J

    2013-01-01

    Skier?s thumb is a partial or complete rupture of the ulnar collateral ligament of the metacarpophalangeal joint of the thumb. It is an often-encountered injury and can lead to chronic pain and instability when diagnosed incorrectly. Knowledge of the anatomy and accurate physical examination are essential in the evaluation of a patient with skier?s thumb. This article provides a review of the relevant anatomy, the correct method of physical examination and the options for additional imaging a...

  13. ISSN 2073 ISSN 2073 9990 East Cent. Afr. J. s 9990 East Cent. Afr ...

    African Journals Online (AJOL)

    Hp 630 Dual Core

    Typically a fibrous interconnection joins the thumbs4. The muscles innervated by the ulnar nerve tend to be attached to the ulnar most thumb and those innervated by the median nerve tend to be attached to the radial most thumb. [4]. Collateral ligaments are shared between the thumbs. The neurovascular bundles may ...

  14. MRI shows thickening and altered diffusion in the median and ulnar nerves in multifocal motor neuropathy

    DEFF Research Database (Denmark)

    Haakma, Wieke; Jongbloed, Bas A.; Froeling, Martijn

    2017-01-01

    Objectives To study disease mechanisms in multifocal motor neuropathy (MMN) with magnetic resonance imaging (MRI) and diffusion tensor imaging (DTI) of the median and ulnar nerves. Methods We enrolled ten MMN patients, ten patients with amyotrophic lateral sclerosis (ALS) and ten healthy controls...

  15. Nonlinear dynamic model for skidding behavior of angular contact ball bearings

    Science.gov (United States)

    Han, Qinkai; Chu, Fulei

    2015-10-01

    A three-dimensional nonlinear dynamic model is proposed to predict the skidding behavior of angular contact ball bearings under combined load condition. The centrifugal and gyroscopic effects induced by ball rotation and revolution, Hertz contact between the ball and inner/outer races, discontinuous contact between the ball and cage and elastohydrodynamic lubrication are considered in the model. Through comparisons with the tested results of the reference, the dynamic model is verified. Based upon these, variations of ball slipping speed with time and space are discussed for the bearing under combined load condition. It is shown that radial load leads to the fluctuations in the slipping velocity of the ball contacting with inner/outer races, especially for the ball in load-decreasing regions. Adding the radial load would significantly increase the amplitude and range of slipping velocity, indicating that the skidding becomes more serious. As the ball still withstands contact load in the load-decreasing region, large slipping velocity would increase the temperature of both bearing and lubricant oil, intensify the wear and then might shorten the bearing service life. Therefore, the radial load should be considered carefully in the design and monitoring of rotating machinery.

  16. Neurotization of the biceps muscle by end-to-side neurorraphy between ulnar and musculocutaneous nerves. A series of five cases.

    Science.gov (United States)

    Franciosi, L F; Modestti, C; Mueller, S F

    1998-01-01

    Three patients with avulsed C5, C6, and C7 roots and two patients with avulsed C5 and C6 roots after trauma of the brachial plexus, were treated by neurotization of the biceps using nerve fibers derived from the ulnar nerve and obtained by end-to-side neurorraphy between the ulnar and musculocutaneous nerves. The age of patients ranged from 19 to 45. The interval between the accident and surgery was 2 to 13 months. Return of biceps contraction was observed 4 to 6 months after surgery. Four patients recovered grade 4 elbow flexion. One 45-year-old patient did not obtain any biceps contraction after 9 months.

  17. INDEX FINGER POSITION AND FORCE OF THE HUMAN FIRST DORSAL INTEROSSEUS AND ITS ULNAR NERVE ANTAGONIST

    NARCIS (Netherlands)

    ZIJDEWIND, Inge; KERNELL, D

    In normal subjects, maximum voluntary contraction (MVC) and electrical ulnar nerve stimulation (UNS; 30-Hz bursts of 0.33 s) were systematically compared with regard to the forces generated in different directions (abduction/adduction and flexion) and at different degrees of index finger abduction.

  18. Helicon modes in uniform plasmas. III. Angular momentum

    International Nuclear Information System (INIS)

    Stenzel, R. L.; Urrutia, J. M.

    2015-01-01

    Helicons are electromagnetic waves with helical phase fronts propagating in the whistler mode in magnetized plasmas and solids. They have similar properties to electromagnetic waves with angular momentum in free space. Helicons are circularly polarized waves carrying spin angular momentum and orbital angular momentum due to their propagation around the ambient magnetic field B 0 . These properties have not been considered in the community of researchers working on helicon plasma sources, but are the topic of the present work. The present work focuses on the field topology of helicons in unbounded plasmas, not on helicon source physics. Helicons are excited in a large uniform laboratory plasma with a magnetic loop antenna whose dipole axis is aligned along or across B 0 . The wave fields are measured in orthogonal planes and extended to three dimensions (3D) by interpolation. Since density and B 0 are uniform, small amplitude waves from loops at different locations can be superimposed to generate complex antenna patterns. With a circular array of phase shifted loops, whistler modes with angular and axial wave propagation, i.e., helicons, are generated. Without boundaries radial propagation also arises. The azimuthal mode number m can be positive or negative while the field polarization remains right-hand circular. The conservation of energy and momentum implies that these field quantities are transferred to matter which causes damping or reflection. Wave-particle interactions with fast electrons are possible by Doppler shifted resonances. The transverse Doppler shift is demonstrated. Wave-wave interactions are also shown by showing collisions between different helicons. Whistler turbulence does not always have to be created by nonlinear wave-interactions but can also be a linear superposition of waves from random sources. In helicon collisions, the linear and/or orbital angular momenta can be canceled, which results in a great variety of field topologies. The work

  19. Lipomatous macrodystrophy of the ulnar nerve: Role of magnetic resonance in the diagnosis

    International Nuclear Information System (INIS)

    Capelastegui, A.; Astigarraga, E.; Galan, V.

    1996-01-01

    Lipomatous macrodystrophy is a rare cause of macrodactyly that can be included among the bening adipose tissue tumors of the peripheral nerves. We present a case involving ulnar nerve, which is an unusual location since most of the reported cases correspond to median nerve. the magnetic resonance (MR) images are analyzed, and their role in the characterization and definition of the extension of these lesions is assessed. 4 refs

  20. Radiocephalic Fistula Complicated by Distal Ischemia: Treatment by Ulnar Artery Dilatation

    International Nuclear Information System (INIS)

    Raynaud, Alain; Novelli, Luigi; Rovani, Xavier; Carreres, Thierry; Bourquelot, Pierre; Hermelin, Alain; Angel, C.; Beyssen, B.

    2010-01-01

    Hand ischemic steal syndrome due to a forearm arteriovenous fistula is a rare occurrence. However, its frequency is increasing with the rise in numbers of elderly and diabetic patients. This complication, which is more common for proximal than for distal accesses, can be very severe and may cause loss of hand function, damage to fingers, and even amputation of fingers or the hand. Its treatment is difficult and often leads to access loss. We report here a case of severe hand ischemia related to a radiocephalic fistula successfully treated by ulnar artery dilatation.

  1. Validity of F-wave minimal latency of median and ulnar nerves for diagnosis and severity assessment of carpal tunnel syndrome in type II diabetes mellitus

    International Nuclear Information System (INIS)

    Hussain, A.; Habib, S.S.; Omar, S.A.; Drees, M.A.

    2011-01-01

    Type II diabetes mellitus is a common problem and is sometimes associated with Carpal Tunnel Syndrome (CTS) due to compression of median nerve at wrist. Electrophysiological tests are frequently used for its diagnosis. In this work, F-wave minimal latency (FWML) difference between median and ulnar nerve and F-ratio is used to facilitate the diagnosis and severity of CTS in type II diabetes mellitus (T2DM). Methods: Thirty control cases were selected who were physically fit for normal electrophysiological values. Thirty-two patients with a long history of type II diabetes mellitus were studied for electro-diagnostic tests. All patients had clinical evidence of CTS. Among all diabetics about 20 cases had poor glycaemic control (HbA1c>7.5). F-wave minimal latency (FWML) were measured in median and ulnar nerves and F-ratio of median nerve were also noted. The mean values in different groups were compared using t-test and p greater or equal to 0.05 was considered significant. Results: In control group, the ulnar FWML was either equal or slightly longer that the median FWML value. In CTS group with type II diabetes mellitus the FWML value of median nerve were significantly longer than FWML of the ulnar nerve. Moreover, in uncontrolled diabetic patients the FWML values was very much longer than controlled group. Similarly the F-ratio of median nerve was significantly low. Conclusion: In addition to the specific criteria for CTS diagnosis, the parameters like FWML difference in median and ulnar nerve with reduced F-ratio of median nerve can be useful in establishing the diagnosis and severity of CTS in type II diabetes mellitus. (author)

  2. Carpal tunnel syndrome in the elderly: nerve conduction parameters Síndrome do túnel do carpo em idosos: parâmetros de condução nervosa

    Directory of Open Access Journals (Sweden)

    Thiago Guimarães Naves

    2010-02-01

    Full Text Available OBJECTIVE: To establish nerve conduction parameters for carpal tunnel syndrome (CTS electrodiagnosis in the elderly. METHOD: Thirty healthy subjects (65-86 years, 9 male and 21 female, were studied. Routine median and ulnar sensory and motor nerve conduction studies, median mixed palmar latency, comparative latency techniques median to ulnar (sensory, mixed and motor lumbrical-interossei, median to radial (sensory, and combined sensory index (CSI were performed in both hands. RESULTS: The upper limits of normality (97.5% were: median sensory distal latency 3.80 ms (14 cm; median motor distal latency 4.30 ms (8 cm; median palmar latency 2.45 ms (8 cm; lumbrical-interossei latency difference 0.60 ms (8 cm; comparative median to radial 0.95 ms (10 cm; comparative median to ulnar 0.95 ms (14 cm; comparative palmar median to ulnar 0.50 ms (8 cm; and CSI 2.20 ms. Sensory and mixed latencies were measured at peak. CONCLUSION: Our results establish new nerve conduction parameters for mild CTS electrodiagnosis in the elderly and will be helpful to reduce the number of false positive cases in this age.OBJETIVO: Estabelecer parâmetros de condução nervosa para o eletrodiagnóstico da síndrome do túnel do carpo (STC em idosos. MÉTODO: Foram estudadas 30 pessoas idosas (65-86 anos saudáveis. Foi realizado estudo de condução nervosa sensitiva e motora rotineira dos nervos mediano e ulnar, latência palmar mista do mediano, técnicas de comparação de latências mediano-ulnar (sensitivo, misto e motor lumbrical-interósseo e mediano-radial (sensitivo e índice sensitivo combinado (ISC em ambas as mãos. RESULTADOS: Os limites superiores de normalidade, 97,5% foram: latência distal sensitiva do mediano 3,80 ms (14 cm; latência distal motora do mediano 4,30 ms (8 cm, latência palmar do mediano 2,45 ms (8 cm, diferença de latência lumbrical-interósseo 0,60 ms (8 cm, comparação mediano-radial 0,95 ms (10 cm, comparação mediano-ulnar 0,95 ms (14

  3. Angular approach combined to mechanical model for tool breakage detection by eddy current sensors

    OpenAIRE

    Ritou , Mathieu; Garnier , Sébastien; Furet , Benoît; Hascoët , Jean-Yves

    2014-01-01

    International audience; The paper presents a new complete approach for Tool Condition Monitoring (TCM) in milling. The aim is the early detection of small damages so that catastrophic tool failures are prevented. A versatile in-process monitoring system is introduced for reliability concerns. The tool condition is determined by estimates of the radial eccentricity of the teeth. An adequate criterion is proposed combining mechanical model of milling and angular approach. Then, a new solution i...

  4. Hypothenar hammer syndrome: long-term follow-up after ulnar artery reconstruction with the lateral circumflex femoral artery.

    Science.gov (United States)

    de Niet, A; Van Uchelen, J H

    2017-06-01

    In symptomatic patients with hypothenar hammer syndrome, the occluded part of the ulnar artery can be reconstructed with an autologous graft. Venous grafts are used frequently, but they are known for their low patency rate. Arterial grafts show better patency rates than venous grafts in coronary bypass surgery. We performed 11 ulnar artery reconstructions with the descending branch of the lateral circumflex femoral artery and compared these with previously performed venous reconstructions. All patients with an arterial graft reconstruction had a patent graft at a mean follow-up of 63 months. In addition, nine out of 11 patients reported improvement in their symptoms. The patency rate of venous reconstructions in hypothenar hammer syndrome is significantly lower. Arterial grafting for hypothenar hammer syndrome has superior patency compared with venous grafting; we recommend it as the surgical treatment of choice for symptomatic hypothenar hammer syndrome. 4.

  5. Gouy Phase Radial Mode Sorter for Light: Concepts and Experiments

    Science.gov (United States)

    Gu, Xuemei; Krenn, Mario; Erhard, Manuel; Zeilinger, Anton

    2018-03-01

    We present an in principle lossless sorter for radial modes of light, using accumulated Gouy phases. The experimental setups have been found by a computer algorithm, and can be intuitively understood in a geometric way. Together with the ability to sort angular-momentum modes, we now have access to the complete two-dimensional transverse plane of light. The device can readily be used in multiplexing classical information. On a quantum level, it is an analog of the Stern-Gerlach experiment—significant for the discussion of fundamental concepts in quantum physics. As such, it can be applied in high-dimensional and multiphotonic quantum experiments.

  6. Gouy Phase Radial Mode Sorter for Light: Concepts and Experiments.

    Science.gov (United States)

    Gu, Xuemei; Krenn, Mario; Erhard, Manuel; Zeilinger, Anton

    2018-03-09

    We present an in principle lossless sorter for radial modes of light, using accumulated Gouy phases. The experimental setups have been found by a computer algorithm, and can be intuitively understood in a geometric way. Together with the ability to sort angular-momentum modes, we now have access to the complete two-dimensional transverse plane of light. The device can readily be used in multiplexing classical information. On a quantum level, it is an analog of the Stern-Gerlach experiment-significant for the discussion of fundamental concepts in quantum physics. As such, it can be applied in high-dimensional and multiphotonic quantum experiments.

  7. Effect of therapeutic ultrasound intensity on subcutaneous tissue temperature and ulnar nerve conduction velocity.

    Science.gov (United States)

    Kramer, J F

    1985-02-01

    Twenty subjects completed 5 min. periods of sonation, at each of six US intensities, over the ulnar nerve in the proximal forearm. All posttreatment NCV's differed significantly from the respective pretreatment velocities. The immediate posttreatment NCV associated with placebo US was significantly (p less than 0.01) less than that observed immediately pretreatment (2.81 m/s), while the five clinical US intensities produced significantly increased immediate posttreatment velocities: 0.5 w/cm2 (2.23 m/s) at (p less than 0.05), and 1.0 w/cm2 (2.78 m/s), 1.5 w/cm2 (3.15 m/s), 2.0 w/cm2 (4.47 m/s) and 2.5 w/cm2 (2.97 m/s) at (p less than 0.01). The posttreatment velocities associated with the five clinical intensities were all significantly greater (p less than 0.01) than that associated with placebo US. Subcutaneous tissue temperatures were directly related to the intensity of US. Not until US intensity had reached 1.5 w/cm2 did the heating effect of US negate the cooling effect of the US transmission gel, to produce significantly increased subcutaneous tissue temperatures after 5 min. sonation. The decreased ulnar motor NCV's associated with placebo US are attributed to the cooling effect of the US transmission gel. The increased ulnar motor NCV's associated with the clinical intensities of US are attributed to the deep heating effect of US. The breakdown of this linear relationship at 2.5 w/cm2 intensity suggests that at this point heating on the nerve and/or the mechanical effects of US were of sufficient magnitude so as to limit the increase in conduction velocity. Sonation over an area of approximately 4.5 times the soundhead for 5 min., along the proximal forearm, at clinical intensities did not have a bipositive effect on motor NCV.

  8. Electrophysiologic studies of the thoracic limb of the horse.

    Science.gov (United States)

    Blythe, L L; Kitchell, R L

    1982-09-01

    The cutaneous innervation of the thoracic limb was investigated in 18 barbiturate-anesthetized horses, using electrophysiologic techniques. The cutaneous area (CA) innervated by each cutaneous nerve was delineated in at least 4 horses by stroking the hairs with a small watercolor brush while recording from the nerve. Mapping of adjacent CA revealed areas of considerable overlap. The part of a CA of a given nerve supplied only by that nerve is referred to as its autonomous zone (AZ). In contrast to the standard textbook illustrations cutaneous branches of the axillary, radial, musculocutaneous, and ulnar nerves overlapped extensively in the antebrachium. Clinically testable AZ were found in the antebrachium for the caudal cutaneous antebrachial nerve of the ulnar nerve and in the carpus and manus for the cutaneous branches of the median, ulnar, and musculocutaneous nerves; AZ were not found for the cutaneous branches of the radial and axillary nerves.

  9. Resultado da neurotização do nervo ulnar para o músculo bíceps braquial na lesão do plexo braquial Results of ulnar nerve neurotization to brachial biceps muscle in brachial plexus injury

    Directory of Open Access Journals (Sweden)

    Marcelo Rosa de Rezende

    2012-12-01

    Full Text Available OBJETIVO: Avaliar de forma crítica os fatores que influenciam os resultados da neurotização do nervo ulnar no ramo motor do músculo bíceps braquial, visando a restauração da flexão do cotovelo em pacientes com lesão do plexo braquial. MÉTODOS: 19 pacientes, 18 homens e uma mulher, com idade média de 28,7 anos foram avaliados entre fevereiro de 2003 e maio de 2007. Oito pacientes apresentavam lesão das raízes C5-C6 e 11, das raízes C5-C6-C7. O intervalo de tempo médio entre a injúria e o tratamento cirúrgico foi 7,5 meses. Quatro pacientes apresentavam fraturas cervicais associadas à lesão do plexo braquial. O seguimento pós-operatório foi de 15,7 meses. RESULTADO: Oito pacientes recuperaram força de flexão do cotovelo MRC grau 4; dois, MRC grau 3 e nove, MRC OBJECTIVE: To evaluate the factors influencing the results of ulnar nerve neurotization at the motor branch of the brachial biceps muscle, aiming at the restoration of elbow flexion in patients with brachial plexus injury. METHODS: 19 patients, with 18 men and 1 woman, mean age 28.7 years. Eight patients had injury to roots C5-C6 and 11, to roots C5-C6-C7. The average time interval between injury and surgery was 7.5 months. Four patients had cervical fractures associated with brachial plexus injury. The postoperative follow-up was 15.7 months. RESULTS: Eight patients recovered elbow flexion strength MRC grade 4; two, MRC grade 3 and nine, MRC <3. There was no impairment of the previous ulnar nerve function. CONCLUSION: The surgical results of ulnar nerve neurotization at the motor branch of brachial biceps muscle are dependent on the interval between brachial plexus injury and surgical treatment, the presence of associated fractures of the cervical spine and occipital condyle, residual function of the C8-T1 roots after the injury and the involvement of the C7 root. Signs of reinnervation manifested up to 3 months after surgery showed better results in the long term

  10. Performance of a large-area GEM detector read out with wide radial zigzag strips

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Aiwu, E-mail: azhang@fit.edu; Bhopatkar, Vallary; Hansen, Eric; Hohlmann, Marcus; Khanal, Shreeya; Phipps, Michael; Starling, Elizabeth; Twigger, Jessie; Walton, Kimberly

    2016-03-01

    A 1-meter-long trapezoidal Triple-GEM detector with wide readout strips was tested in hadron beams at the Fermilab Test Beam Facility in October 2013. The readout strips have a special zigzag geometry and run radially with an azimuthal pitch of 1.37 mrad to measure the azimuthal ϕ-coordinate of incident particles. The zigzag geometry of the readout reduces the required number of electronic channels by a factor of three compared to conventional straight readout strips while preserving good angular resolution. The average crosstalk between zigzag strips is measured to be an acceptable 5.5%. The detection efficiency of the detector is (98.4±0.2)%. When the non-linearity of the zigzag-strip response is corrected with track information, the angular resolution is measured to be (193±3) μrad, which corresponds to 14% of the angular strip pitch. Multiple Coulomb scattering effects are fully taken into account in the data analysis with the help of a stand-alone Geant4 simulation that estimates interpolated track errors.

  11. [False traumatic aneurysm of the ulnar artery in a teenager].

    Science.gov (United States)

    Nour, M; Talha, H; El Idrissi, R; Lahraoui, Y; Ouazzani, L; Oubejja, H; Erraji, M; Zerhouni, H; Ettayebi, F

    2014-12-01

    Most aneurysms of hand arteries are traumatic. It is a generally rare unrecognized pathology. Complications are serious (embolism and thromboses of interdigital arteries). Two main causes can be recalled: acute trauma, with development of a false aneurysm; repeated microtrauma (hand hammer syndrome), with occurrence of an arterial dysplasic aneurysm. The diagnosis is based on the presence of a pulsatile mass, with finger dysesthesia, unilateral Raynaud's phenomenon. It is confirmed by duplex Doppler. Arteriography is necessary but can be replaced by an angio-MR. We report a case of false traumatic aneurysm of the ulnar artery in a teenager. This case illustrates this rare condition and opens discussion on therapeutic options. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  12. Professional AngularJS

    CERN Document Server

    Karpov, Valeri

    2015-01-01

    A comprehensive guide to AngularJS, Google's open-source client-side framework for app development. Most of the existing guides to AngularJS struggle to provide simple and understandable explanations for more advanced concepts. As a result, some developers who understand all the basic concepts of AngularJS struggle when it comes to building more complex real-world applications. Professional AngularJS provides a thorough understanding of AngularJS, covering everything from basic concepts, such as directives and data binding, to more advanced concepts like transclusion, build systems, and auto

  13. Relativistic low angular momentum accretion: long time evolution of hydrodynamical inviscid flows

    Science.gov (United States)

    Mach, Patryk; Piróg, Michał; Font, José A.

    2018-05-01

    We investigate relativistic low angular momentum accretion of inviscid perfect fluid onto a Schwarzschild black hole. The simulations are performed with a general-relativistic, high-resolution (second-order), shock-capturing, hydrodynamical numerical code. We use horizon-penetrating Eddington–Finkelstein coordinates to remove inaccuracies in regions of strong gravity near the black hole horizon and show the expected convergence of the code with the Michel solution and stationary Fishbone–Moncrief toroids. We recover, in the framework of relativistic hydrodynamics, the qualitative behavior known from previous Newtonian studies that used a Bondi background flow in a pseudo-relativistic gravitational potential with a latitude-dependent angular momentum at the outer boundary. Our models exhibit characteristic ‘turbulent’ behavior and the attained accretion rates are lower than those of the Bondi–Michel radial flow. For sufficiently low values of the asymptotic sound speed, geometrically thick tori form in the equatorial plane surrounding the black hole horizon while accretion takes place mainly through the poles.

  14. Injury to ulnar collateral ligament of thumb.

    Science.gov (United States)

    Madan, Simerjit Singh; Pai, Dinker R; Kaur, Avneet; Dixit, Ruchita

    2014-02-01

    Injury of the ulnar collateral ligament (UCL) of thumb can be incapacitating if untreated or not treated properly. This injury is notorious for frequently being missed by inexperienced health care personnel in emergency departments. It has frequently been described in skiers, but also occurs in other sports such as rugby, soccer, handball, basketball, volleyball and even after a handshake. The UCL of the thumb acts as a primary restraint to valgus stress and is injured if hyperabduction and hyperextension forces are applied to the first metacarpophalangeal joint. The diagnosis is best established clinically, though MRI is the imaging modality of choice. Many treatment options exist, surgical treatment being offered depending on various factors, including timing of presentation (acute or chronic), grade (severity of injury), displacement (Stener lesion), location of tear (mid-substance or peripheral), associated or concomitant surrounding tissue injury (bone, volar plate, etc.), and patient-related factors (occupational demands, etc.). This review aims to identify the optimal diagnostic techniques and management options for UCL injury available thus far. © 2014 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.

  15. Uncertainty principle for angular position and angular momentum

    International Nuclear Information System (INIS)

    Franke-Arnold, Sonja; Barnett, Stephen M; Yao, Eric; Leach, Jonathan; Courtial, Johannes; Padgett, Miles

    2004-01-01

    The uncertainty principle places fundamental limits on the accuracy with which we are able to measure the values of different physical quantities (Heisenberg 1949 The Physical Principles of the Quantum Theory (New York: Dover); Robertson 1929 Phys. Rev. 34 127). This has profound effects not only on the microscopic but also on the macroscopic level of physical systems. The most familiar form of the uncertainty principle relates the uncertainties in position and linear momentum. Other manifestations include those relating uncertainty in energy to uncertainty in time duration, phase of an electromagnetic field to photon number and angular position to angular momentum (Vaccaro and Pegg 1990 J. Mod. Opt. 37 17; Barnett and Pegg 1990 Phys. Rev. A 41 3427). In this paper, we report the first observation of the last of these uncertainty relations and derive the associated states that satisfy the equality in the uncertainty relation. We confirm the form of these states by detailed measurement of the angular momentum of a light beam after passage through an appropriate angular aperture. The angular uncertainty principle applies to all physical systems and is particularly important for systems with cylindrical symmetry

  16. CONSTRAINTS ON THE RADIAL VARIATION OF GRAIN GROWTH IN THE AS 209 CIRCUMSTELLAR DISK

    International Nuclear Information System (INIS)

    Pérez, Laura M.; Carpenter, John M.; Isella, Andrea; Ricci, Luca; Sargent, Anneila I.; Chandler, Claire J.; Andrews, Sean M.; Harris, Robert J.; Calvet, Nuria; Corder, Stuartt A.; Deller, Adam T.; Dullemond, Cornelis P.; Linz, Hendrik; Greaves, Jane S.; Henning, Thomas; Kwon, Woojin; Lazio, Joseph; Mundy, Lee G.; Storm, Shaye; Testi, Leonardo

    2012-01-01

    We present dust continuum observations of the protoplanetary disk surrounding the pre-main-sequence star AS 209, spanning more than an order of magnitude in wavelength from 0.88 to 9.8 mm. The disk was observed with subarcsecond angular resolution (0.''2-0.''5) to investigate radial variations in its dust properties. At longer wavelengths, the disk emission structure is notably more compact, providing model-independent evidence for changes in the grain properties across the disk. We find that physical models which reproduce the disk emission require a radial dependence of the dust opacity κ ν . Assuming that the observed wavelength-dependent structure can be attributed to radial variations in the dust opacity spectral index (β), we find that β(R) increases from β 1.5 for R ∼> 80 AU, inconsistent with a constant value of β across the disk (at the 10σ level). Furthermore, if radial variations of κ ν are caused by particle growth, we find that the maximum size of the particle-size distribution (a max ) increases from submillimeter-sized grains in the outer disk (R ∼> 70 AU) to millimeter- and centimeter-sized grains in the inner disk regions (R ∼ max (R) with predictions from physical models of dust evolution in protoplanetary disks. For the dust composition and particle-size distribution investigated here, our observational constraints on a max (R) are consistent with models where the maximum grain size is limited by radial drift.

  17. Study protocol: non-displaced distal radial fractures in adult patients: three weeks vs. five weeks of cast immobilization: a randomized trial.

    Science.gov (United States)

    Bentohami, Abdelali; de Korte, Niels; Sosef, Nico; Goslings, Johan Carel; Bijlsma, Taco; Schep, Niels

    2014-01-20

    Up to 30% of patients suffer from long-term functional restrictions following conservative treatment of distal radius fractures. Whether duration of cast immobilisation influences functional outcome remains unclear. The aim of the study is to evaluate whether the duration of immobilization of non or minimally displaced distal radial fractures can be safely reduced. We will compare three weeks of plaster cast immobilization with five weeks of plaster cast immobilization in adult patient with non or minimally displaced distal radial fractures. a prospective randomized clinical trial. adult (>18 years) (independent in activities of daily living) patients with a non/minimal displaced distal radius fracture (dorsal angulation 15°, ulnar positive variance immobilization versus five weeks of plaster cast immobilization.Main study parameters: primary outcome parameters: Patient related wrist evaluation (PRWE) Quick Disability of Arm, Shoulder and Hand (QUICKDASH) score after a one year follow-up, and secondary parameters: range of motion, pain level (VAS) and complications. The expectation of this study is that shorter duration of plaster cast immobilisation is beneficial for the patient with a distal radius fracture. This risk of specific complications is low and generally similar in both treatment options. Moreover, the burden of the study is not much higher compared to standard treatment. Follow-up is standardized according to current trauma guidelines. Literature indicates that both treatment options from the study are accepted for displaced distal radius fractures. No clear advantage for one treatment options is found at present in the literature, although there is no level I evidence present. This trial will provide level-1 evidence for the comparison of consolidation and functional outcome between two treatment options for non-displaced distal radial fractures. The gathered data may support the development of a clinical guideline for conservative treatment of

  18. A phenomenological approach to angular momentum transfer in deep inelastic heavy ion collisions

    International Nuclear Information System (INIS)

    Barbosa, V.C.; Soares, P.C.; Oliveira, Edgar C. de; Gomes, Luiz Carlos

    1985-01-01

    The total angular momentum transfer measured in the reactions 165 Ho on 176 Yb, 154 Sm and sup(Nat)Ag at 1400 MeV and 86 Kr + 152 Sm 610 MeV were analised on the basis of a classical model with friction forces including, besides the relative motion of the ions, their rotations and quadrupole vibrations. The ratios of tangential or pivotal to radial friction were fixed by the analysis and found to be 1/20. No strong evidences of the sticking mechanisms were found. (Author) [pt

  19. Triangular fibrocartilage lesions: comparison STIR sequence versus arthroscopy findings

    International Nuclear Information System (INIS)

    Wang Zhi; Meng; Xianghong; Wang Linsen; Suo Yongmei

    2013-01-01

    Objective: To explore the diagnostic value of short TI inversion recovery (STIR) sequence in evaluating triangular fibrocartilage (TFC) lesions, and to compare the findings with the arthroscopy findings. Materials and Methods: Wrist joint MR examination using STIR sequence and arthroscopy were performed in 56 patients with TFC lesions. The parameters of STIR sequence were: TR: 1164 ms, TE: 16 ms, and TI: 90 ms. The sensibility, specificity, positive predictive value, negative predictive value, and accuracy in the diagnosis of TFC lesions with STIR sequence were calculated, using arthroscopy as the standard. Results: (1) STIR manifested 10 patients with normal TFC; 6 with small edema or mucous degeneration in the body portion but not involving joint surface edge; 6 with horizontal avulsion in the body portion, but not involving joint surface edge; 6 with avulsion involving joint surface edge; 11 with perforation in central portion; 6 with avulsion in radial attached end; 5 with avulsion in ulnar attached end; 3 with avulsion in both radial and ulnar attached ends; 3 with irregular shape and thin on the whole TFC. (2) Arthroscopy manifested 21 patients with normal TFC; 8 with avulsion involving joint surface edge; 10 with perforation in central portion; 7 with avulsion in radial attached end; 5 with avulsion in ulnar attached end; 2 with avulsion in both radial and ulnar attached ends; 3 with irregular shape on the whole TFC. Using STIR sequence, the sensibility, specificity, positive predictive value, negative predictive value. and accuracy were 85.7%, 23.8%, 65.2%, 50%, and 62.5%, respectively, in detection of TFC lesions, with arthroscopy as the standard. Conclusion: STIR sequence has high diagnostic value in detection of TFC lesions. (authors)

  20. Prevalence of ulnar-to-median nerve motor fiber anastomosis (Riché-Cannieu communicating branch) in hand: An electrophysiological study

    Science.gov (United States)

    Ahadi, Tannaz; Raissi, Gholam Reza; Yavari, Masood; Majidi, Lobat

    2016-01-01

    Background: Two main muscles studied in the hand for evaluation of median nerve injuries are opponens pollicis (OP) and abductor pollicis brevis (APB). However, Riché-Cannieu communicating branch (RCCB) may limit the use of these muscles in electrodiagnosis. This condition is confusing in the case of median nerve injuries. This study was conducted to evaluate the prevalence of RCCB. Methods: Twenty-three consecutive cases of complete median nerve injury were studied. Evoked responses via stimulation of median and ulnar nerves in the wrist and recording with needle in the thenar area were studied. Results: Of the patients, 82.6% exhibited RCCB. In 14 (60.8%) cases the OP and in 19(82.6%) cases APB was supplied by the ulnar nerve. Conclusion: RCCB was detected to be 60.8% in OP and 82.6% in APB, so OP is preferable to APB in the study of median nerve. PMID:27390694

  1. Error Correction of Radial Displacement in Grinding Machine Tool Spindle by Optimizing Shape and Bearing Tuning

    OpenAIRE

    Khairul Jauhari; Achmad Widodo; Ismoyo Haryanto

    2015-01-01

    In this article, the radial displacement error correction capability of a high precision spindle grinding caused by unbalance force was investigated. The spindle shaft is considered as a flexible rotor mounted on two sets of angular contact ball bearing. Finite element methods (FEM) have been adopted for obtaining the equation of motion of the spindle. In this paper, firstly, natural frequencies, critical frequencies, and amplitude of the unbalance response caused by resi...

  2. THE ANGULAR DISTRIBUTION OF Lyα RESONANT PHOTONS EMERGING FROM AN OPTICALLY THICK MEDIUM

    International Nuclear Information System (INIS)

    Yang Yang; Shu Chiwang; Roy, Ishani; Fang Lizhi

    2013-01-01

    We investigate the angular distribution of Lyα photons scattering or emerging from an optically thick medium. Since the evolution of specific intensity I in frequency space and angular space are coupled with each other, we first develop the WENO numerical solver to find the time-dependent solutions of the integro-differential equation of I in frequency and angular space simultaneously. We first show that the solutions with the Eddington approximation, which assume that I is linearly dependent on the angular variable μ, yield similar frequency profiles of the photon flux as those without the Eddington approximation. However, the solutions of the μ distribution evolution are significantly different from those given by the Eddington approximation. First, the angular distribution of I is found to be substantially dependent on the frequency of the photons. For photons with the resonant frequency ν 0 , I contains only a linear term of μ. For photons with frequencies at the double peaks of the flux, the μ-distribution is highly anisotropic; most photons are emitted radially forward. Moreover, either at ν 0 or at the double peaks, the μ distributions actually are independent of the initial μ distribution of photons of the source. This is because the photons with frequencies either at ν 0 or the double peaks undergo the process of forgetting their initial conditions due to resonant scattering. We also show that the optically thick medium is a collimator of photons at the double peaks. Photons from the double peaks form a forward beam with a very small opening angle.

  3. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  4. Recovery from distal ulnar motor conduction block injury: serial EMG studies.

    Science.gov (United States)

    Montoya, Liliana; Felice, Kevin J

    2002-07-01

    Acute conduction block injuries often result from nerve compression or trauma. The temporal pattern of clinical, electrophysiologic, and histopathologic changes following these injuries has been extensively studied in experimental animal models but not in humans. Our recent evaluation of a young man with an injury to the deep motor branch of the ulnar nerve following nerve compression from weightlifting exercises provided the opportunity to follow the course and recovery of a severe conduction block injury with sequential nerve conduction studies. The conduction block slowly and completely resolved, as did the clinical deficit, over a 14-week period. The reduction in conduction block occurred at a linear rate of -6.1% per week. Copyright 2002 Wiley Periodicals, Inc.

  5. Upper extremity peripheral neuropathies: role and impact of MR imaging on patient management

    International Nuclear Information System (INIS)

    Andreisek, Gustav; Burg, Doris; Studer, Ansgar; Weishaupt, Dominik

    2008-01-01

    To investigate the role of MR imaging (MRI) in the evaluation of peripheral nerve lesions of the upper extremities and to assess its impact on the patient management. Fifty-one patients with clinical evidence of radial, median, and/or ulnar nerve lesions and unclear or ambiguous clinical findings had MRI of the upper extremity at 1.5 T. MR images and clinical data were reviewed by two blinded radiologists and a group of three clinical experts, respectively, with regard to radial, median, and/or ulnar nerve, as well as muscle abnormalities. MRI and clinical findings were correlated using Spearman's (p) rank correlation test. The impact of MRI on patient management was assessed by the group of experts and ranked as ''major,'' ''moderate,'' or ''no'' impact. The correlation of MRI and clinical findings was moderate for the assessment of the median/radial nerve and muscles (p=0.51/0.51/0.63, respectively) and weak for the ulnar nerve (p=0.40). The impact of MRI on patient management was assessed as ''major'' in 24/51 (47%), ''moderate'' in 19/51 (37%), and ''no'' in 8/51 (16%) patients. MRI in patients with upper extremity peripheral neuropathies and unclear or ambiguous clinical findings substantially influences the patient management. (orig.)

  6. Current evidence for effectiveness of interventions for cubital tunnel syndrome, radial tunnel syndrome, instability, or bursitis of the elbow: a systematic review.

    Science.gov (United States)

    Rinkel, Willem D; Schreuders, Ton A R; Koes, Bart W; Huisstede, Bionka M A

    2013-12-01

    To provide an evidence-based overview of the effectiveness of interventions for 4 nontraumatic painful disorders sharing the anatomic region of the elbow: cubital tunnel syndrome, radial tunnel syndrome, elbow instability, and olecranon bursitis. The Cochrane Library, PubMed, Embase, PEDro, and CINAHL were searched to identify relevant reviews and randomized clinical trials (RCTs). Two reviewers independently extracted data and assessed the quality of the methodology. A best-evidence synthesis was used to summarize the results. One systematic review and 6 RCTs were included. For the surgical treatment of cubital tunnel syndrome (1 review, 3 RCTs), comparing simple decompression with anterior ulnar nerve transposition, no evidence was found in favor of either one of these. Limited evidence was found in favor of medial epicondylectomy versus anterior transposition and for early postoperative therapy versus immobilization. No evidence was found for the effect of local steroid injection in addition to splinting. No RCTs were found for radial tunnel syndrome. For olecranon bursitis (1 RCT), limited evidence for effectiveness was found for methylprednisolone acetate injection plus naproxen. Concerning elbow instability, including 2 RCTs, one showed that nonsurgical treatment resulted in similar results compared with surgery, whereas the other found limited evidence for the effectiveness in favor of early mobilization versus 3 weeks of immobilization after surgery. In this review no, or at best, limited evidence was found for the effectiveness of nonsurgical and surgical interventions to treat painful cubital tunnel syndrome, radial tunnel syndrome, elbow instability, or olecranon bursitis. Well-designed and well-conducted RCTs are clearly needed in this field.

  7. Asymmetry of radial and symmetry of tangential neuronal migration pathways in developing human fetal brains

    Directory of Open Access Journals (Sweden)

    Yuta eMiyazaki

    2016-01-01

    Full Text Available AbstractThe radial and tangential neural migration pathways are two major neuronal migration streams in humans that are critical during corticogenesis. Corticogenesis is a complex process of neuronal proliferation that is followed by neuronal migration and the formation of axonal connections. Existing histological assessments of these two neuronal migration pathways have limitations inherent to microscopic studies and are confined to small anatomic regions of interest. Thus, little evidence is available about their three-dimensional fiber pathways and development throughout the entire brain. In this study, we imaged and analyzed radial and tangential migration pathways in the whole human brain using high-angular resolution diffusion MR imaging (HARDI tractography. We imaged ten fixed, postmortem fetal (17 gestational weeks (GW, 18 GW, 19 GW, three 20 GW, three 21 GW and 22 GW and eight in vivo newborn (two 30 GW, 34 GW, 35 GW and four 40 GW brains with no neurological/pathological conditions. We statistically compared the volume of the left and right radial and tangential migration pathways, and the volume of the radial migration pathways of the anterior and posterior regions of the brain. In specimens 22 GW or younger, the volume of radial migration pathways of the left hemisphere was significantly larger than that of the right hemisphere. The volume of posterior radial migration pathways was also larger when compared to the anterior pathways in specimens 22 GW or younger. In contrast, no significant differences were observed in the radial migration pathways of brains older than 22 GW. Moreover, our study did not identify any significant differences in volumetric laterality in the tangential migration pathways. These results suggest that these two neuronal migration pathways develop and regress differently, and radial neuronal migration varies regionally based on hemispheric and anterior-posterior laterality, potentially explaining regional

  8. A peculiar distribution of radial velocities of faint radio-galaxies with 13.0<=msub(corr)<=15.5

    International Nuclear Information System (INIS)

    Karoji, H.; Nottale, L.; Vigier, J.-P.

    1976-01-01

    A sample of 41 radio-galaxies with 13.0<=msub(corr)<=15.5 has been analyzed to test the angular redshift anisotropy discovered on Sc I galaxies by Rubin, Rubin and Ford (1973). The sample does not present their anisotropy but contains an even more curious distribution of radial velocities which suggests that the Rubin-Ford effect results from an anomalous redshift of light when it travels through clusters of galaxies. (Auth.)

  9. Diagnostic Performance of the Extensor Carpi Ulnaris (ECU) Synergy Test to Detect Sonographic ECU Abnormalities in Chronic Dorsal Ulnar-Sided Wrist Pain.

    Science.gov (United States)

    Sato, Junko; Ishii, Yoshinori; Noguchi, Hideo

    2016-01-01

    The extensor carpi ulnaris (ECU) tendon synergy test is a simple and unique diagnostic maneuver for evaluation of chronic dorsal ulnar-sided wrist pain, which applies isolated tension to the ECU without greatly stressing other structures. This study aimed to investigate the diagnostic performance of the ECU synergy test to detect ECU abnormalities on sonography. Forty affected wrists from 39 consecutive patients with chronic dorsal ulnar-sided wrist pain that continued for greater than 1 month were examined with the ECU synergy test and sonography. The sensitivity, specificity, positive predictive value, and negative predictive value of the ECU synergy test to detect ECU abnormalities were evaluated. We compared the results of the ECU synergy test between groups with and without ECU abnormalities and also compared the ages, sexes, and symptomatic durations of the patients between groups with positive and negative ECU synergy test results and between the groups with and without ECU abnormalities. The sensitivity, specificity, positive predictive value, and negative predictive value were 73.7%, 85.7%, 82.4%, and 78.3%, respectively. There was significant difference in the ECU synergy test results between the groups with and without ECU abnormalities (P synergy test could be a useful provocative maneuver to detect ECU abnormalities in patients with chronic dorsal ulnar-sided wrist pain. © 2016 by the American Institute of Ultrasound in Medicine.

  10. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  11. Angular dependence of the attosecond time delay in the H 2 + ion

    Science.gov (United States)

    Kheifets, Anatoli; Serov, Vladislav

    2016-05-01

    Angular dependence of attosecond time delay relative to polarization of light can now be measured using combination of RABBITT and COLTRIMS techniques. This dependence brings particularly useful information in molecules where it is sensitive to the orientation of the molecular axis. Here we extend the theoretical studies of and consider a molecular ion H2+in combination of an attosecond pulse train and a dressing IR field which is a characteristic set up of a RABBIT measurement. We solve the time-dependent Schrödinger equation using a fast spherical Bessel transformation (SBT) for the radial variable, a discrete variable representation for the angular variables and a split-step technique for the time evolution. The use of SBT ensures correct phase of the wave function for a long time evolution which is especially important in time delay calculations. To speed up computations, we implement an expanding coordinate (EC) system which allows us to reach space sizes and time periods unavailable by other techniques. Australian Research Council DP120101805.

  12. Optical Angular Momentum

    International Nuclear Information System (INIS)

    Arimondo, Ennio

    2004-01-01

    For many years the Institute of Physics has published books on hot topics based on a collection of reprints from different journals, including some remarks by the editors of each volume. The book on Optical Angular Momentum, edited by L Allen, S M Barnett and M J Padgett, is a recent addition to the series. It reproduces forty four papers originally published in different journals and in a few cases it provides direct access to works not easily accessible to a web navigator. The collection covers nearly a hundred years of progress in physics, starting from an historic 1909 paper by Poynting, and ending with a 2002 paper by Padgett, Barnett and coworkers on the measurement of the orbital angular momentum of a single photon. The field of optical angular momentum has expanded greatly, creating an interdisciplinary attraction for researchers operating in quantum optics, atomic physics, solid state physics, biophysics and quantum information theory. The development of laser optics, especially the control of single mode sources, has made possible the specific design of optical radiation modes with a high degree of control on the light angular momentum. The editors of this book are important figures in the field of angular momentum, having contributed to key progress in the area. L Allen published an historical paper in 1999, he and M J Padgett (together with M Babiker) produced few years ago a long review article which is today still the most complete basic introduction to the angular momentum of light, while S M Barnett has contributed several high quality papers to the progress of this area of physics. The editors' choice provides an excellent overview to all readers, with papers classified into eight different topics, covering the basic principles of the light and spin and orbital angular momentum, the laboratory tools for creating laser beams carrying orbital angular momentum, the optical forces and torques created by laser beams carrying angular momentum on

  13. Dependence of the trapping regions with the radial electric field in TJ-II

    International Nuclear Information System (INIS)

    Guasp, J.; Liniers, M.

    1997-01-01

    The influence of the electric field upon the radial and angular distributions of trapped ions of energies between 0.1 and 1 keV in TJ-II is analysed. Near the magnetic axis, with moderate electric fields, the trapped fraction increases for negative potentials and decreases for positive ones. Nevertheless for high potentials this decreasing for positive sign can be reversed. Near the plasma periphery trapping is affected only for high potentials and always increases, independently of the potential sign. The sensibility to negative potentials is always higher than for the positive ones. These trapping changes are almost uniform in poloidal and toroidal angular profiles and affect mainly to marginally trapped or passing particles. Nevertheless for high potentials or energie the resonances modify this behaviour and inhibit the increasing of trapping in the outer side or the torus. For the locally trapped population fraction a steady decrease with the potential appears independently of the sign, except very near the magnetic axis or the plasma periphery. The global result of all these partial effects is the presence of a wide trapping minimum for moderate positive electric potential, potential that increases with the ion energy as well as a strong increase for high electric fields of either sign, more visible for negative potentials and high energies. For the locally trapped population a steady decrease with potential appears independently of the sign. All these effects can be explained by the combined action of the appearance and elimination of radial magnetic barriers and of the electric field resonances. (Author)

  14. Intervenção coronariana percutânea primária pelo acesso transulnar: segurança e eficácia Primary percutaneous coronary intervention through transulnar approach: safety and effectiveness

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2008-10-01

    Full Text Available O acesso transradial é seguro e eficaz na realização de procedimentos coronários. Porém, seu uso pode estar comprometido em casos de variações anatômicas da artéria radial, espasmo e negatividade do teste de Allen. O acesso transulnar surge como uma alternativa viável em substituição à abordagem transradial. Reportamos o caso de um paciente submetido à angioplastia primária pela via ulnar com sucesso, sem complicações isquêmicas da mão, a despeito de oclusão prévia da artéria radial correspondente.The transradial approach is safe and effective for coronary procedures. However, its use may be compromised in cases of variations in radial artery anatomy, spasms, and negative Allen's test. The transulnar approach emerges as a viable alternative to transradial approach. We report on a patient who underwent primary angioplasty via ulnar artery without ischemic hand complications despite prior occlusion of the ipsilateral radial artery.

  15. Stability of radial and non-radial pulsation modes of massive ZAMS models

    International Nuclear Information System (INIS)

    Odell, A.P.; Pausenwein, A.; Weiss, W.W.; Hajek, A.

    1987-01-01

    The authors have computed non-adiabatic eigenvalues for radial and non-radial pulsation modes of star models between 80 and 120 M solar with composition of chi=0.70 and Z=0.02. The radial fundamental mode is unstable in models with mass greater than 95 M solar , but the first overtone mode is always stable. The non-radial modes are all stable for all models, but the iota=2 f-mode is the closest to being driven. The non-radial modes are progressively more stable with higher iota and with higher n (for both rho- and g-modes). Thus, their results indicate that radial pulsation limits the upper mass of a star

  16. Median and Ulnar Neuropathy Assessment in Parkinson’s Disease regarding Symptom Severity and Asymmetry

    Directory of Open Access Journals (Sweden)

    Nilgul Yardimci

    2016-01-01

    Full Text Available Background. While increasing evidence suggests comorbidity of peripheral neuropathy (PNP and Parkinson’s disease (PD, the pathogenesis of PNP in PD is still a debate. The aim of this article is to search the core PD symptoms such as rigidity and tremor as contributing factors to mononeuropathy development while emphasizing each individual patient’s asymmetric symptom severity. Methods. We studied 62 wrists and 62 elbows of 31 patients (mean age 66.48±10.67 and 64 wrists and 64 elbows of 32 age-gender matched healthy controls (mean age 62.03±10.40, p=0.145. The Hoehn and Yahr disability scale and Unified Parkinson’s Disease Rated Scale were used to determine the severity of the disease. Results. According to electrodiagnostic criteria, we confirmed median neuropathy in 16.12% (bilateral in two-thirds of the patients and ulnar neuropathy in 3.22% of the PD group. While mean age (p=0.003, age at PD onset (p=0.019, and H&Y scores (p=0.016 were significant, tremor and rigidity scores were not. The comparison of the mean indices of electrophysiologic parameters indicated subclinical median and ulnar nerve demyelination both at the wrist and at the elbow in the patient groups where a longer disease duration and mild tremor and rigidity scores are prominent, remarkably. Conclusion. A disease related peripheral neurodegeneration beyond symptom severity occurs in PD.

  17. A GEM readout with radial zigzag strips and linear charge-sharing response

    Science.gov (United States)

    Zhang, Aiwu; Hohlmann, Marcus; Azmoun, Babak; Purschke, Martin L.; Woody, Craig

    2018-04-01

    We study the position sensitivity of radial zigzag strips intended to read out large GEM detectors for tracking at future experiments. Zigzag strips can cover a readout area with fewer strips than regular straight strips while maintaining good spatial resolution. Consequently, they can reduce the number of required electronic channels and related cost for large-area GEM detector systems. A non-linear relation between incident particle position and hit position measured from charge sharing among zigzag strips was observed in a previous study. We significantly reduce this non-linearity by improving the interleaving of adjacent physical zigzag strips. Zigzag readout structures are implemented on PCBs and on a flexible foil and are tested using a 10 cm × 10 cm triple-GEM detector scanned with a strongly collimated X-ray gun on a 2D motorized stage. Angular resolutions of 60-84 μrad are achieved with a 1.37 mrad angular strip pitch at a radius of 784 mm. On a linear scale this corresponds to resolutions below 100 μm.

  18. MR tomography of the elbow joint

    Energy Technology Data Exchange (ETDEWEB)

    Zwaan, M.; Rinast, E.; Weiss, H.D.; Pressler, M.; Vogel, H.

    1989-03-01

    MR examinations of the elbow joint of three healthy subjects and a comparison with corresponding sections of anatomical preparations show that MR tomography enables not only an excellent differentiation of muscles, tendons and of the articular capsule, but will also visualise vessels and nerve tracts. MR tomography proved superior to the conventional methods in demonstration of separate fragments and inflammatory changes in the bone on examining 11 pathological elbow joints: congenital malformation, osteochondritis dissecans, ostitis, ulnar and radial nerve lesions, completely healed radius fracture and epicondylitis of the radial and ulnar humerus. Epicondylitis could not be demonstrated by MR. Magnetic resonance tomography seems to be the only method that enables direct visualisation of the nerve paths at the elbow joint.

  19. The role of radial nodes of atomic orbitals for chemical bonding and the periodic table.

    Science.gov (United States)

    Kaupp, Martin

    2007-01-15

    The role of radial nodes, or of their absence, in valence orbitals for chemical bonding and periodic trends is discussed from a unified viewpoint. In particular, we emphasize the special role of the absence of a radial node whenever a shell with angular quantum number l is occupied for the first time (lack of "primogenic repulsion"), as with the 1s, 2p, 3d, and 4f shells. Although the consequences of the very compact 2p shell (e.g. good isovalent hybridization, multiple bonding, high electronegativity, lone-pair repulsion, octet rule) are relatively well known, it seems that some of the aspects of the very compact 3d shell in transition-metal chemistry are less well appreciated, e.g., the often weakened and stretched bonds at equilibrium structure, the frequently colored complexes, and the importance of nondynamical electron-correlation effects in bonding. Copyright (c) 2006 Wiley Periodicals, Inc.

  20. Contribuição ao estudo anatômico da inervação sensitiva do punho

    Directory of Open Access Journals (Sweden)

    Edie Benedito Caetano

    2009-11-01

    Full Text Available Objetivo: descrever a inervação sensitiva do punho cujo conhecimento é de fundamental importância para a exploração cirúrgica da região. Métodos: foi realizada dissecação macroscópica de 15 membros superiores de cadáveres no Laboratório de Anatomia da Faculdade de Medicina da PUC-SP utilizando lupa cirúrgica (2,5 x 340 mm como meio de magnificação. Resultados: as dissecações realizadas mostraram que os seguintes nervos contribuem para a inervação sensitiva do punho: nervos interósseo anterior e cutâneo palmar (ramos do nervo mediano, ramo cutâneo dorsal do nervo ulnar, ramo superficial do nervo radial e nervo interósseo posterior (originados do nervo radial. Não registramos a inervação do punho pelos nervos cutâneo medial (ramo do nervo ulnar e cutâneo lateral do antebraço (ramo do nervo musculocutâneo. Conclusões: os nervos interósseo posterior e interósseo anterior são os principais responsáveis pela inervação da articulação do punho. Os nervos ramo superficial do nervo radial, ramo cutâneo dorsal do nervo ulnar também contribuem com frequência para inervar a articulação do punho. O ramo profundo do nervo ulnar e o nervo mediano contribuem, porém de maneira pouco frequente e inconstante para a inervação dessa articulação.

  1. Feasibility tests of a high resolution sampling radial drift chamber

    International Nuclear Information System (INIS)

    Huth, J.

    1985-01-01

    The design concept and results of feasibility tests for a vertex detector intended for use in the TPC-PEP4/9 experiment are presented. The detector is based on a slow radial drift in dimethyl ether. High resolution localization of the avalanches at the sense wire is accomplished with nearby pickup wires and the utilization of waveform sampling electronics. The avalanche angular coordinate measurements, combined with knowledge of the electric field distribution and drift velocity permit reconstruction of the trajectory using essentially all track information. Measurements with a test chamber constructed to study characteristics of avalanche localization indicate that the recoverable track information in one centimeter of dimethyl ether at 1.5 atm is equivalent to 30 measurements of 40 μm accuracy. (orig.)

  2. THE EFFECTS OF ANGULAR MOMENTUM ON HALO PROFILES

    Energy Technology Data Exchange (ETDEWEB)

    Lentz, Erik W; Rosenberg, Leslie J [Physics Department, University of Washington, Seattle, WA 98195-1580 (United States); Quinn, Thomas R, E-mail: lentze@phys.washington.edu, E-mail: ljrosenberg@phys.washington.edu, E-mail: trq@astro.washington.edu [Astronomy Department, University of Washington, Seattle, WA 98195-1580 (United States)

    2016-05-10

    The near universality of DM halo density profiles provided by N -body simulations proved to be robust against changes in total mass density, power spectrum, and some forms of initial velocity dispersion. Here we study the effects of coherently spinning up an isolated DM-only progenitor on halo structure. Halos with spins within several standard deviations of the simulated mean ( λ ≲ 0.20) produce profiles with negligible deviations from the universal form. Only when the spin becomes quite large ( λ ≳ 0.20) do departures become evident. The angular momentum distribution also exhibits a near universal form, which is also independent of halo spin up to λ ≲ 0.20. A correlation between these epidemic profiles and the presence of a strong bar in the virialized halo is also observed. These bar structures bear resemblance to the radial orbit instability in the rotationless limit.

  3. Angular correlation methods

    International Nuclear Information System (INIS)

    Ferguson, A.J.

    1974-01-01

    An outline of the theory of angular correlations is presented, and the difference between the modern density matrix method and the traditional wave function method is stressed. Comments are offered on particular angular correlation theoretical techniques. A brief discussion is given of recent studies of gamma ray angular correlations of reaction products recoiling with high velocity into vacuum. Two methods for optimization to obtain the most accurate expansion coefficients of the correlation are discussed. (1 figure, 53 references) (U.S.)

  4. Avaliação morfométrica de fibras nervosas do nervo ulnar após reparação cirúrgica com auto-enxerto e prótese tubular em cães

    Directory of Open Access Journals (Sweden)

    Ângelo João Stopiglia

    1998-01-01

    Full Text Available The purpose of this study was to evaluate, by morphometric analysis, the regenerated nerve fibers of dogs, after 26 weeks of observation, in gaps of the ulnar nerves substituted by allografts and tubular prosthesis of silicone. The ulnar nerves of four dogs were processed for electron microscopic evaluation. Six fields, with 1750 µm², for each dog and each procedure, were photographed at 1880x. A morphometric computer based analysis (Sigma Scan - Jandel Co., USA resulted in the following numbers (average numbers in micrometers. 1. ulnar nerve with tubular prosthesis- a: myelinated fiber diameter-5.12 ± 1.67. b: myelinated axon diameter: 4.08 ± 1.52. c: myelin sheath thickness-0.52 ± 0.18. d: unmyelinated axon diameter: 0.98 ± 0.37. 2. ulnar nerve with allograft- a: myelinated fiber diameter: 6.04 ± 2.27. b: myelinated axon diameter: 4.59 ± 1.95. c: myelin sheath thickness: 0.72 ± 0.23. d: unmyelinated axon diameter: 0.96 ± 0.40. The morphometric analysis after 26 weeks of nerve repair didn’t show a significant difference between the two surgical procedures.

  5. Quantifying the impact of mergers on the angular momentum of simulated galaxies

    Science.gov (United States)

    Lagos, Claudia del P.; Stevens, Adam R. H.; Bower, Richard G.; Davis, Timothy A.; Contreras, Sergio; Padilla, Nelson D.; Obreschkow, Danail; Croton, Darren; Trayford, James W.; Welker, Charlotte; Theuns, Tom

    2018-02-01

    We use EAGLE to quantify the effect galaxy mergers have on the stellar specific angular momentum of galaxies, jstars. We split mergers into dry (gas-poor)/wet (gas-rich), major/minor and different spin alignments and orbital parameters. Wet (dry) mergers have an average neutral gas-to-stellar mass ratio of 1.1 (0.02), while major (minor) mergers are those with stellar mass ratios ≥0.3 (0.1-0.3). We correlate the positions of galaxies in the jstars-stellar mass plane at z = 0 with their merger history, and find that galaxies of low spins suffered dry mergers, while galaxies of normal/high spins suffered predominantly wet mergers, if any. The radial jstars profiles of galaxies that went through dry mergers are deficient by ≈0.3 dex at r ≲ 10 r50 (with r50 being the half-stellar mass radius), compared to galaxies that went through wet mergers. Studying the merger remnants reveals that dry mergers reduce jstars by ≈30 per cent, while wet mergers increase it by ≈10 per cent, on average. The latter is connected to the build-up of the bulge by newly formed stars of high rotational speed. Moving from minor to major mergers accentuates these effects. When the spin vectors of the galaxies prior to the dry merger are misaligned, jstars decreases by a greater magnitude, while in wet mergers corotation and high orbital angular momentum efficiently spun-up galaxies. We predict what would be the observational signatures in the jstars profiles driven by dry mergers: (i) shallow radial profiles and (ii) profiles that rise beyond ≈10 r50, both of which are significantly different from spiral galaxies.

  6. Macroscopic angular momentum states of Bose-Einstein condensates in toroidal traps

    International Nuclear Information System (INIS)

    Benakli, M.; Raghavan, S.; Fantoni, S.; Shenoy, S.R.; Smerzi, A.

    1997-11-01

    We consider a Bose-Einstein condensate (BEC) of N atoms of repulsive interaction ∼ U 0 , in an elliptical trap, axially pierced by a Gaussian-intensity laser beam, forming an effective (quasi-2D) toroidal trap with minimum at radial distance ρ = ρ p . The macroscopic angular momentum states Ψ l (ρ,θ) ∼ √NΦ l (ρ)e ilθ for integer l spread up to ρ max ∼ (NU 0 ) 1/4 >> ρ p . The spreading lowers rotational energies, so estimated low metastability barriers can support large l max ∼ (NU 0 ) 1/4 , l (ρ) 2 -Φ 0 (ρ) 2 is a signature of BEC rotation. Results are insensitive to off-axis laser displacements ρ 0 , for ρ 0 ρ max << 1. (author)

  7. Optical angular momentum and atoms.

    Science.gov (United States)

    Franke-Arnold, Sonja

    2017-02-28

    Any coherent interaction of light and atoms needs to conserve energy, linear momentum and angular momentum. What happens to an atom's angular momentum if it encounters light that carries orbital angular momentum (OAM)? This is a particularly intriguing question as the angular momentum of atoms is quantized, incorporating the intrinsic spin angular momentum of the individual electrons as well as the OAM associated with their spatial distribution. In addition, a mechanical angular momentum can arise from the rotation of the entire atom, which for very cold atoms is also quantized. Atoms therefore allow us to probe and access the quantum properties of light's OAM, aiding our fundamental understanding of light-matter interactions, and moreover, allowing us to construct OAM-based applications, including quantum memories, frequency converters for shaped light and OAM-based sensors.This article is part of the themed issue 'Optical orbital angular momentum'. © 2017 The Author(s).

  8. Optical angular momentum and atoms

    Science.gov (United States)

    2017-01-01

    Any coherent interaction of light and atoms needs to conserve energy, linear momentum and angular momentum. What happens to an atom’s angular momentum if it encounters light that carries orbital angular momentum (OAM)? This is a particularly intriguing question as the angular momentum of atoms is quantized, incorporating the intrinsic spin angular momentum of the individual electrons as well as the OAM associated with their spatial distribution. In addition, a mechanical angular momentum can arise from the rotation of the entire atom, which for very cold atoms is also quantized. Atoms therefore allow us to probe and access the quantum properties of light’s OAM, aiding our fundamental understanding of light–matter interactions, and moreover, allowing us to construct OAM-based applications, including quantum memories, frequency converters for shaped light and OAM-based sensors. This article is part of the themed issue ‘Optical orbital angular momentum’. PMID:28069766

  9. Anterior subcutaneous transposition of the ulnar nerve improves neurological function in patients with cubital tunnel syndrome

    Directory of Open Access Journals (Sweden)

    Wei Huang

    2015-01-01

    Full Text Available Although several surgical procedures exist for treating cubital tunnel syndrome, the best surgical option remains controversial. To evaluate the efficacy of anterior subcutaneous transposition of the ulnar nerve in patients with moderate to severe cubital tunnel syndrome and to analyze prognostic factors, we retrospectively reviewed 62 patients (65 elbows diagnosed with cubital tunnel syndrome who underwent anterior subcutaneous transposition. Preoperatively, the initial severity of the disease was evaluated using the McGowan scale as modified by Goldberg: 18 patients (28% had grade IIA neuropathy, 20 (31% had grade IIB, and 27 (42% had grade III. Postoperatively, according to the Wilson & Krout criteria, treatment outcomes were excellent in 38 patients (58%, good in 16 (25%, fair in 7 (11%, and poor in 4 (6%, with an excellent and good rate of 83%. A negative correlation was found between the preoperative McGowan grade and the postoperative Wilson & Krout score. The patients having fair and poor treatment outcomes had more advanced age, lower nerve conduction velocity, and lower action potential amplitude compared with those having excellent and good treatment outcomes. These results suggest that anterior subcutaneous transposition of the ulnar nerve is effective and safe for the treatment of moderate to severe cubital tunnel syndrome, and initial severity, advancing age, and electrophysiological parameters can affect treatment outcome.

  10. What velocities and eccentricities tell us about radial migration

    Directory of Open Access Journals (Sweden)

    Schönrich R.

    2012-02-01

    Full Text Available This note attempts to interpret some of the recent findings about a downtrend in the mean azimuthal velocity of low [α/Fe] thin disc stars with increasing metallicity. The presence of such a trend was predicted in the model of [19], albeit with a slightly steeper slope. We show that in a simple picture a Galactic disc without mixing in angular momenta would display an exceedingly steep trend, while in the case of complete mixing of all stars the trend has to vanish. The difference between model and observational data can hence be interpreted as the consequence of the radial abundance gradient in the model being too high resulting in an underestimate of the migration strength. We shortly discuss the value of eccentricity distributions in constraining structure and history of the Galactic disc.

  11. Neurophysiological localisation of ulnar neuropathy at the elbow: validation of diagnostic criteria developed by a taskforce of the Danish Society of Clinical Neurophysiology

    DEFF Research Database (Denmark)

    Pugdahl, Kirsten; Beniczky, Sándor; Wanscher, Benedikte

    2017-01-01

    OBJECTIVE: This study validates consensus criteria for localisation of ulnar neuropathy at elbow (UNE) developed by a taskforce of the Danish Society of Clinical Neurophysiology and compares them to the existing criteria from the American Association of Neuromuscular and Electrodiagnostic Medicine...

  12. Upper-extremity phocomelia reexamined: a longitudinal dysplasia.

    Science.gov (United States)

    Goldfarb, Charles A; Manske, Paul R; Busa, Riccardo; Mills, Janith; Carter, Peter; Ezaki, Marybeth

    2005-12-01

    In contrast to longitudinal deficiencies, phocomelia is considered a transverse, intercalated segmental dysplasia. Most patients demonstrate severe, but not otherwise classifiable, upper-extremity deformities, which usually cannot be placed into one of three previously described phocomelia groups. Additionally, these phocomelic extremities do not demonstrate true segmental deficits; the limb is also abnormal proximal and distal to the segmental defect. The purpose of this investigation was to present evidence that upper-extremity abnormalities in patients previously diagnosed as having phocomelia in fact represent a proximal continuum of radial or ulnar longitudinal dysplasia. The charts and radiographs of forty-one patients (sixty extremities) diagnosed as having upper-extremity phocomelia were reviewed retrospectively. On the basis of the findings on the radiographs, the disorders were categorized into three groups: (1) proximal radial longitudinal dysplasia, which was characterized by an absent proximal part of the humerus, a nearly normal distal part of the humerus, a completely absent radius, and a radial-sided hand dysplasia; (2) proximal ulnar longitudinal dysplasia, characterized by a short one-bone upper extremity that bifurcated distally and by severe hand abnormalities compatible with ulnar dysplasia; and (3) severe combined dysplasia, with type A characterized by an absence of the forearm segment (i.e., the radius and ulna) and type B characterized by absence of the arm and forearm (i.e., the hand attached to the thorax). Twenty-nine limbs in sixteen patients could be classified as having proximal radial longitudinal dysplasia. Systemic medical conditions such as thrombocytopenia-absent radius syndrome were common in those patients, but additional musculoskeletal conditions were rare. Twenty limbs in seventeen patients could be classified as having proximal ulnar longitudinal dysplasia. Associated musculoskeletal abnormalities, such as proximal femoral

  13. Nerve ultrasound reliability of upper limbs: Effects of examiner training.

    Science.gov (United States)

    Garcia-Santibanez, Rocio; Dietz, Alexander R; Bucelli, Robert C; Zaidman, Craig M

    2018-02-01

    Duration of training to reliably measure nerve cross-sectional area with ultrasound is unknown. A retrospective review was performed of ultrasound data, acquired and recorded by 2 examiners-an expert and either a trainee with 2 months (novice) or a trainee with 12 months (experienced) of experience. Data on median, ulnar, and radial nerves were reviewed for 42 patients. Interrater reliability was good and varied most with nerve site but little with experience. Coefficient of variation (CoV) range was 9.33%-22.5%. Intraclass correlation coefficient (ICC) was good to excellent (0.65-95) except ulnar nerve-wrist/forearm and radial nerve-humerus (ICC = 0.39-0.59). Interrater differences did not vary with nerve size or body mass index. Expert-novice and expert-experienced interrater differences and CoV were similar. The ulnar nerve-wrist expert-novice interrater difference decreased with time (r s  = -0.68, P = 0.001). A trainee with at least 2 months of experience can reliably measure upper limb nerves. Reliability varies by nerve and location and slightly improves with time. Muscle Nerve 57: 189-192, 2018. © 2017 Wiley Periodicals, Inc.

  14. All Madelung deformities are not endocrine.

    Science.gov (United States)

    Kumar, Ajay; Rai, Gopal K; Akhtar, Javed; Phillip, Rajeev; Gutch, Manish; Arya, T V S

    2013-10-01

    Madelung deformity is a rare inherited disorder associated with endocrine disorders like Turner's syndrome, pseudohypoparathyroidism, but can be seen with short stature homeobox deficiency conditions such as Leri-Weill dyschondrosteosis (LWD) and Langers mesomelic dysplasia. It has also been reported following trauma to the distal radius epiphysis neoplasia mucopolysaccharidosis (MPS) and achondroplasia. Madelung deformity is an abnormality of distal radial epiphysis where in progressive ulnar and volar tilt of the articular surface occurring in association with distal subluxation of ulna. A 13-year-old girl was referred to us for evaluation of bilateral deformity of wrist and short stature. There was ulnar deviation and dorsal tilt of bilateral hands without history of pain to the joint trauma and family history of similar illness. On X-ray, wrist showed malformed distal radial epiphysis with dorsal and ulnar shift and with increased length of phalanges suggestive of Madelung deformity. X-ray spine was normal. Ultrasound abdomen showed normal uterus and ovary and her follicle stimulating hormone. Luteinizing hormone was normal and so was urine MPS screening. Based on the above points the diagnosis of LWD was made.

  15. All Madelung deformities are not endocrine

    Directory of Open Access Journals (Sweden)

    Ajay Kumar

    2013-01-01

    Full Text Available Madelung deformity is a rare inherited disorder associated with endocrine disorders like Turner′s syndrome, pseudohypoparathyroidism, but can be seen with short stature homeobox deficiency conditions such as Leri-Weill dyschondrosteosis (LWD and Langers mesomelic dysplasia. It has also been reported following trauma to the distal radius epiphysis neoplasia mucopolysaccharidosis (MPS and achondroplasia. Madelung deformity is an abnormality of distal radial epiphysis where in progressive ulnar and volar tilt of the articular surface occurring in association with distal subluxation of ulna. A 13-year-old girl was referred to us for evaluation of bilateral deformity of wrist and short stature. There was ulnar deviation and dorsal tilt of bilateral hands without history of pain to the joint trauma and family history of similar illness. On X-ray, wrist showed malformed distal radial epiphysis with dorsal and ulnar shift and with increased length of phalanges suggestive of Madelung deformity. X-ray spine was normal. Ultrasound abdomen showed normal uterus and ovary and her follicle stimulating hormone. Luteinizing hormone was normal and so was urine MPS screening. Based on the above points the diagnosis of LWD was made.

  16. Angular Momentum in Dwarf Galaxies

    Directory of Open Access Journals (Sweden)

    Del Popolo A.

    2014-06-01

    Full Text Available We study the “angular momentum catastrophe” in the framework of interaction among baryons and dark matter through dynamical friction. By means of Del Popolo (2009 model we simulate 14 galaxies similar to those investigated by van den Bosch, Burkert and Swaters (2001, and calculate the distribution of their spin parameters and the angular momenta. Our model gives the angular momentum distribution which is in agreement with the van den Bosch et al. observations. Our result shows that the “angular momentum catastrophe” can be naturally solved in a model that takes into account the baryonic physics and the exchange of energy and angular momentum between the baryonic clumps and dark matter through dynamical friction.

  17. Data-oriented development with AngularJS

    CERN Document Server

    Waikar, Manoj

    2015-01-01

    This book helps beginner-level AngularJS developers organize AngularJS applications by discussing important AngularJS concepts and best practices. If you are an experienced AngularJS developer but haven't written directives or haven't created custom HTML controls before, then this book is ideal for you.

  18. AngularJS web application development

    CERN Document Server

    Darwin, Peter Bacon

    2013-01-01

    The book will be a step-by-step guide showing the readers how to build a complete web app with AngularJSJavaScript developers who want to learn AngularJS for developing web apps. Knowledge of JavaScript and HTML is expected. No knowledge of AngularJS is required.

  19. Sensory nerve action potentials and sensory perception in women with arthritis of the hand.

    Science.gov (United States)

    Calder, Kristina M; Martin, Alison; Lydiate, Jessica; MacDermid, Joy C; Galea, Victoria; MacIntyre, Norma J

    2012-05-10

    Arthritis of the hand can limit a person's ability to perform daily activities. Whether or not sensory deficits contribute to the disability in this population remains unknown. The primary purpose of this study was to determine if women with osteoarthritis (OA) or rheumatoid arthritis (RA) of the hand have sensory impairments. Sensory function in the dominant hand of women with hand OA or RA and healthy women was evaluated by measuring sensory nerve action potentials (SNAPs) from the median, ulnar and radial nerves, sensory mapping (SM), and vibratory and current perception thresholds (VPT and CPT, respectively) of the second and fifth digits. All SNAP amplitudes were significantly lower for the hand OA and hand RA groups compared with the healthy group (p sensory fibers in the median, ulnar and radial nerves. Less apparent were losses in conduction speed or sensory perception.

  20. Angular momentum of dwarf galaxies

    Science.gov (United States)

    Kurapati, Sushma; Chengalur, Jayaram N.; Pustilnik, Simon; Kamphuis, Peter

    2018-05-01

    Mass and specific angular momentum are two fundamental physical parameters of galaxies. We present measurements of the baryonic mass and specific angular momentum of 11 void dwarf galaxies derived from neutral hydrogen (HI) synthesis data. Rotation curves were measured using 3D and 2D tilted ring fitting routines, and the derived curves generally overlap within the error bars, except in the central regions where, as expected, the 3D routines give steeper curves. The specific angular momentum of void dwarfs is found to be high compared to an extrapolation of the trends seen for higher mass bulge-less spirals, but comparable to that of other dwarf irregular galaxies that lie outside of voids. As such, our data show no evidence for a dependence of the specific angular momentum on the large scale environment. Combining our data with the data from the literature, we find a baryonic threshold of ˜109.1 M⊙ for this increase in specific angular momentum. Interestingly, this threshold is very similar to the mass threshold below which the galaxy discs start to become systematically thicker. This provides qualitative support to the suggestion that the thickening of the discs, as well as the increase in specific angular momentum, are both results of a common physical mechanism, such as feedback from star formation. Quantitatively, however, the amount of star formation observed in our dwarfs appears insufficient to produce the observed increase in specific angular momentum. It is hence likely that other processes, such as cold accretion of high angular momentum gas, also play a role in increasing the specific angular momentum.

  1. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin [College of Medicine, The Catholic University of Korea, Suwon (Korea, Republic of)

    2007-01-15

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  2. Contrast enhanced MR findings of lesions associated with radial scar: correlation with histopathology

    International Nuclear Information System (INIS)

    Chung, Jee Woo; Cha, Eun Suk; Choi, Hyun Joo; Seo, Young Jin

    2007-01-01

    To evaluate the contrast-enhanced MR findings of lesions associated with a radial scar and to compare the MR findings with the histopathology results. From Mar. 2001 to Sep. 2005, 8 patients with a surgically proven radial scar who had undergone MRI, mammography, and ultrasonography were enrolled in this study. The morphological findings and dynamic enhancement pattern of the time-intensity curve were retrospectively reviewed using noncontrast and contrast-enhanced MRI. Mammography and ultrasonography were also analyzed according to the BI-RADS category and correlated with the histopathological diagnosis. The age of the patients ranged from 42 to 53 years (mean, 47 years). Five patients presented with a left breast lesion and the others presented with a right breast lesion. The histopathological diagnosis associated with the radial scar were fibrocystic changes (n = 1) adenosis (n = 2), atypical ductal hyperplasia (n = 2), lobular carcinoma in situ (n = 1), ductal carcinoma in situ (n = 1), and invasive ductal carcinoma (n = 1). In all patients, architectural distortion without microcalcification was observed with mammography. Irregular shaped hypoechoic lesions with an indistinct, spiculated, or angular margin was observed in all patients with ultrasonography. Posterior shadowing was observed in 4 cases. MR enhancement revealed two cases with foci enhancement (adenosis and fibrocystic change), five cases with non-mass-like focal enhancement (fibrocystic change, atypical ductal hyperplasia, lobular carcinoma in situ, ductal carcinoma in situ, invasive ductal carcinoma), and one irregular homogeneous mass enhancement (atypical ducal hyperplasia). The time-signal intensity curves are as follows: persistent type (n = 2), adenosis, and fibrocystic changes, respectively; plateu type (n = 4) one adenosis, two atypical ductal hyperplasia, and one ductal carcinoma in situ; and washout type (n = 2), lobular carcinoma in situ, and invasive ductal carcinoma, respectively

  3. On angularly perturbed Laplace equations in the unit ball of IR{sup n+2} and their distributional boundary values

    Energy Technology Data Exchange (ETDEWEB)

    Massopust, P.R.

    1997-08-01

    All solutions of an in its angular coordinates continuously perturbed Laplace-Beltrami equation in the open unit ball IB{sup n+2} {contained_in} IR{sup n+2}, n {ge} 1, are characterized. Moreover, it is shown that such pertubations yield distributional boundary values which are different from, but algebraically and topologically equivalent to, the hyperfunctions of Lions & Magenes. This is different from the case of radially perturbed Laplace-Beltrami operators (cf. [7]) where one has stability of distributional boundary values under such perturbations.

  4. Acute Compressive Ulnar Neuropathy in a Patient of Dengue Fever: An Unusual Presentation

    Directory of Open Access Journals (Sweden)

    Anil K Mehtani

    2013-04-01

    Full Text Available Introduction: Dengue haemorrhagic fever is known for its haemorrhagic and neurologic complications. Neurologic complications are caused by three mechanism namely neurotropism, systemic complications causing encephalopathy and postinfectious immune-mediated mechanisms. However acute compressive neuropathy due to haemorrhage is not frequent and we could find no literature describing this Case Report: We report a case of acute compressive ulnar neuropathy due to peri neural hematoma, following an attempt at intravenous cannulation in the cubital fossa in a patient of dengue haemorrhagic fever with thrombocytopenia. Immediate fasciotomy and removal of haematoma was performed to relieve the symptoms. Conclusion: Compression neuropathies can be seen in dengue hemorrhagic fever and removal of compressing hematoma relieves symptoms. Keywords: Dengue haemmorrhagic fever; coagulopathy; peri neural haematoma.

  5. In vivo electrophysiological measurement of the rat ulnar nerve with axonal excitability testing

    DEFF Research Database (Denmark)

    Wild, Brandon M.; Morris, Renée; Moldovan, Mihai

    2018-01-01

    Electrophysiology enables the objective assessment of peripheral nerve function in vivo. Traditional nerve conduction measures such as amplitude and latency detect chronic axon loss and demyelination, respectively. Axonal excitability techniques "by threshold tracking" expand upon these measures...... by providing information regarding the activity of ion channels, pumps and exchangers that relate to acute function and may precede degenerative events. As such, the use of axonal excitability in animal models of neurological disorders may provide a useful in vivo measure to assess novel therapeutic...... interventions. Here we describe an experimental setup for multiple measures of motor axonal excitability techniques in the rat ulnar nerve. The animals are anesthetized with isoflurane and carefully monitored to ensure constant and adequate depth of anesthesia. Body temperature, respiration rate, heart rate...

  6. Tissue-engineered rhesus monkey nerve grafts for the repair of long ulnar nerve defects: similar outcomes to autologous nerve grafts

    Directory of Open Access Journals (Sweden)

    Chang-qing Jiang

    2016-01-01

    Full Text Available Acellular nerve allografts can help preserve normal nerve structure and extracellular matrix composition. These allografts have low immunogenicity and are more readily available than autologous nerves for the repair of long-segment peripheral nerve defects. In this study, we repaired a 40-mm ulnar nerve defect in rhesus monkeys with tissue-engineered peripheral nerve, and compared the outcome with that of autograft. The graft was prepared using a chemical extract from adult rhesus monkeys and seeded with allogeneic Schwann cells. Pathomorphology, electromyogram and immunohistochemistry findings revealed the absence of palmar erosion or ulcers, and that the morphology and elasticity of the hypothenar eminence were normal 5 months postoperatively. There were no significant differences in the mean peak compound muscle action potential, the mean nerve conduction velocity, or the number of neurofilaments between the experimental and control groups. However, outcome was significantly better in the experimental group than in the blank group. These findings suggest that chemically extracted allogeneic nerve seeded with autologous Schwann cells can repair 40-mm ulnar nerve defects in the rhesus monkey. The outcomes are similar to those obtained with autologous nerve graft.

  7. Tissue-engineered rhesus monkey nerve gratfs for the repair of long ulnar nerve defects:similar outcomes to autologous nerve gratfs

    Institute of Scientific and Technical Information of China (English)

    Chang-qing Jiang; Jun Hu; Jian-ping Xiang; Jia-kai Zhu; Xiao-lin Liu; Peng Luo

    2016-01-01

    Acellular nerve allogratfs can help preserve normal nerve structure and extracellular matrix composition. These allogratfs have low immu-nogenicity and are more readily available than autologous nerves for the repair of long-segment peripheral nerve defects. In this study, we repaired a 40-mm ulnar nerve defect in rhesus monkeys with tissue-engineered peripheral nerve, and compared the outcome with that of autogratf. The gratf was prepared using a chemical extract from adult rhesus monkeys and seeded with allogeneic Schwann cells. Pathomo-rphology, electromyogram and immunohistochemistry ifndings revealed the absence of palmar erosion or ulcers, and that the morphology and elasticity of the hypothenar eminence were normal 5 months postoperatively. There were no signiifcant differences in the mean peak compound muscle action potential, the mean nerve conduction velocity, or the number of neuroiflaments between the experimental and control groups. However, outcome was signiifcantly better in the experimental group than in the blank group. These ifndings suggest that chemically extracted allogeneic nerve seeded with autologous Schwann cells can repair 40-mm ulnar nerve defects in the rhesus monkey. The outcomes are similar to those obtained with autologous nerve gratf.

  8. A proposed measurement of optical orbital and spin angular momentum and its implications for photon angular momentum

    Directory of Open Access Journals (Sweden)

    Elliot Leader

    2018-04-01

    Full Text Available The expression for the total angular momentum carried by a laser optical vortex beam, splits, in the paraxial approximation, into two terms which seem to represent orbital and spin angular momentum respectively. There are, however, two very different competing versions of the formula for the spin angular momentum, one based on the use of the Poynting vector, as in classical electrodynamics, the other related to the canonical expression for the angular momentum which occurs in Quantum Electrodynamics. I analyze the possibility that a sufficiently sensitive optical measurement could decide which of these corresponds to the actual physical angular momentum carried by the beam. Keywords: Photon, Angular momentum, Laser optics, Particle physics

  9. AngularJS : yksisivuisen web-sovelluksen käyttöliittymän toteutus AngularJS:llä

    OpenAIRE

    Suomijoki, Juha

    2015-01-01

    Opinnäytetyössä tutkittiin mikä on AngularJS-JavaScript-ohjelmistokehys ja miten se soveltuu yksisivuisen web-sovelluksen käyttöliittymän toteutukseen. AngularJS on vuonna 2012 julkaistu Googlen ylläpitämä JavaScript-ohjelmistokehys, joka on tarkoitettu ensisijaisesti yksisivuisten web-sovellusten kehittämiseen. Opinnäytetyön teoriaosuudessa tutkittiin mikä AngularJS on ja mitkä ovat AngularJS:n keskeiset konseptit ja sovelluskomponentit. Tarkastelu pohjautui AngularJS:stä kirjoitettu...

  10. Quark Orbital Angular Momentum

    Directory of Open Access Journals (Sweden)

    Burkardt Matthias

    2015-01-01

    Full Text Available Definitions of orbital angular momentum based on Wigner distributions are used as a framework to discuss the connection between the Ji definition of the quark orbital angular momentum and that of Jaffe and Manohar. We find that the difference between these two definitions can be interpreted as the change in the quark orbital angular momentum as it leaves the target in a DIS experiment. The mechanism responsible for that change is similar to the mechanism that causes transverse single-spin asymmetries in semi-inclusive deep-inelastic scattering.

  11. Rotations and angular momentum

    International Nuclear Information System (INIS)

    Nyborg, P.; Froyland, J.

    1979-01-01

    This paper is devoted to the analysis of rotational invariance and the properties of angular momentum in quantum mechanics. In particular, the problem of addition of angular momenta is treated in detail, and tables of Clebsch-Gordan coefficients are included

  12. Spectral collocation method with a flexible angular discretization scheme for radiative transfer in multi-layer graded index medium

    Science.gov (United States)

    Wei, Linyang; Qi, Hong; Sun, Jianping; Ren, Yatao; Ruan, Liming

    2017-05-01

    The spectral collocation method (SCM) is employed to solve the radiative transfer in multi-layer semitransparent medium with graded index. A new flexible angular discretization scheme is employed to discretize the solid angle domain freely to overcome the limit of the number of discrete radiative direction when adopting traditional SN discrete ordinate scheme. Three radial basis function interpolation approaches, named as multi-quadric (MQ), inverse multi-quadric (IMQ) and inverse quadratic (IQ) interpolation, are employed to couple the radiative intensity at the interface between two adjacent layers and numerical experiments show that MQ interpolation has the highest accuracy and best stability. Variable radiative transfer problems in double-layer semitransparent media with different thermophysical properties are investigated and the influence of these thermophysical properties on the radiative transfer procedure in double-layer semitransparent media is also analyzed. All the simulated results show that the present SCM with the new angular discretization scheme can predict the radiative transfer in multi-layer semitransparent medium with graded index efficiently and accurately.

  13. Angular approach combined to mechanical model for tool breakage detection by eddy current sensors

    Science.gov (United States)

    Ritou, M.; Garnier, S.; Furet, B.; Hascoet, J. Y.

    2014-02-01

    The paper presents a new complete approach for Tool Condition Monitoring (TCM) in milling. The aim is the early detection of small damages so that catastrophic tool failures are prevented. A versatile in-process monitoring system is introduced for reliability concerns. The tool condition is determined by estimates of the radial eccentricity of the teeth. An adequate criterion is proposed combining mechanical model of milling and angular approach.Then, a new solution is proposed for the estimate of cutting force using eddy current sensors implemented close to spindle nose. Signals are analysed in the angular domain, notably by synchronous averaging technique. Phase shifts induced by changes of machining direction are compensated. Results are compared with cutting forces measured with a dynamometer table.The proposed method is implemented in an industrial case of pocket machining operation. One of the cutting edges has been slightly damaged during the machining, as shown by a direct measurement of the tool. A control chart is established with the estimates of cutter eccentricity obtained during the machining from the eddy current sensors signals. Efficiency and reliability of the method is demonstrated by a successful detection of the damage.

  14. Non-power law behavior of the radial profile of phase-space density of halos

    International Nuclear Information System (INIS)

    Popolo, A. Del

    2011-01-01

    We study the pseudo phase-space density, ρ(r)/σ 3 (r), of ΛCDM dark matter halos with and without baryons (baryons+DM, and pure DM), by using the model introduced in Del Popolo (2009), which takes into account the effect of dynamical friction, ordered and random angular momentum, baryons adiabatic contraction and dark matter baryons interplay. We examine the radial dependence of ρ(r)/σ 3 (r) over 9 orders of magnitude in radius for structures on galactic and cluster of galaxies scales. We find that ρ(r)/σ 3 (r) is approximately a power-law only in the range of halo radius resolved by current simulations (down to 0.1% of the virial radius) while it has a non-power law behavior below the quoted scale, with inner profiles changing with mass. The non-power-law behavior is more evident for halos constituted both of dark matter and baryons while halos constituted just of dark matter and with angular momentum chosen to reproduce a Navarro-Frenk-White (NFW) density profile, are characterized by an approximately power-law behavior. The results of the present paper lead to conclude that density profiles of the NFW type are compatible with a power-law behavior of ρ(r)/σ 3 (r), while those flattening to the halo center, like those found in Del Popolo (2009) or the Einasto profile, or the Burkert profile, cannot produce radial profile of the pseudo-phase-space density that are power-laws at all radii. The results argue against universality of the pseudo phase-space density and as a consequence argue against universality of density profiles constituted by dark matter and baryons as also discussed in Del Popolo (2009)

  15. [Case-control study on T-shaped locking internal fixation and external fixation for the treatment of dorsal Barton's fracture].

    Science.gov (United States)

    Chen, Huan-qing; Wen, Xi-le; Li, Yang-ming; Wen, Cong-you

    2015-06-01

    To compare clinical effect of T-shaped locking internal fixation and external fixation in treating dorsal Barton's fracture,and investigate selective strategy of internal fixation. From January 2008 to January 2013, 100 patients with dorsal Barton's fracture were randomly divided into two groups. In treatment group, there were 30 males and 20 females with an average age of (33.8±3.6) years old;30 cases were type B, 20 cases were type C;and treated with T-shaped locking internal fixation. In control group, there were 32 male and 18 females with an average age of (32.9±3.4) years old; 29 cases were type B, 21 cases were type C; and treated with external fixation. Volar tilt, ulnar deviation and radial height at 3 months after operation were detected and compared between two groups. Mechara functional evaluation were used to evaluate postoperative clinical effects. Clinical cure time, postoperative complications,joint mobility and function score were recorded and compared between two groups. In treatment group,volar tilt was (11.9±2.7)°, ulnar deviation was (20.8+ 2.9)°,and radial height was (10.9±1.8) mm; while volar tilt was (9.1±1.6)°, ulnar deviation was (17.1±2.9)°, and radial height was (8.1±1.5) mm in control group. Treatment group was better than control group in volar tilt, ulnar deviation and radial height. Clinical cure time in treatment group was(12.0±2.3) weeks, shorter than control group (18.0±4.1) weeks. The incidence of complications in treatment group was lower than control group. According to Mehara functional evaluation,20 cases got excellent results, 25 good, 3 moderate and 2 poor in treatment group; 16 cases got excellent results, 14 good, 10 moderate and 10 poor in control group. Treatment group was better than control group in clinical effects. T-shaped locking internal fixation with postoperative functional exercise for the treatment of dorsal Barton's fracture fits for biomechanics demands,and has advantages of stable fixation

  16. Effect of platelet-rich plasma combined with demineralised bone matrix on bone healing in rabbit ulnar defects.

    Science.gov (United States)

    Galanis, Vasilios; Fiska, Alice; Kapetanakis, Stylianos; Kazakos, Konstantinos; Demetriou, Thespis

    2017-09-01

    This study evaluates the effect of autologous platelet-rich plasma (PRP) combined with xenogeneic demineralised bone matrix (DBM) on bone healing of critical-size ulnar defects (2-2.5 times the ulnar diameter) in New Zealand White rabbits. Critical-size defects were created unilaterally in the ulna of 36 rabbits, while keeping the contralateral limb intact. They were divided into three groups. In Group A, the defect was filled with autologous PRP and in Group B, with autologous PRP combined with DBM; in Group C, the defect remained empty. The rabbits were euthanised 12 weeks postoperatively. Radiological, biomechanical and histological assessments were carried out and statistical analysis of the results was performed. Group B had significantly higher radiological and histological scores than Groups A and C. Defects in Group B showed significant new bone formation, whereas there was minimal or no new bone formation in Groups A and C. Only specimens in Group B showed macroscopic bone union. Biomechanical evaluation of the treated and intact contralateral limbs in Group B showed significant differences. In this study, statistically significant enhancement of bone healing was found in critical-size defects treated with PRP and DBM, as shown by radiological findings, gross assessment, and biomechanical and histopathological results. Defects in the two other groups remained unbridged. Therefore, PRP was effective only when it was used in combination with a bone graft. Copyright: © Singapore Medical Association

  17. A proposed measurement of optical orbital and spin angular momentum and its implications for photon angular momentum

    Science.gov (United States)

    Leader, Elliot

    2018-04-01

    The expression for the total angular momentum carried by a laser optical vortex beam, splits, in the paraxial approximation, into two terms which seem to represent orbital and spin angular momentum respectively. There are, however, two very different competing versions of the formula for the spin angular momentum, one based on the use of the Poynting vector, as in classical electrodynamics, the other related to the canonical expression for the angular momentum which occurs in Quantum Electrodynamics. I analyze the possibility that a sufficiently sensitive optical measurement could decide which of these corresponds to the actual physical angular momentum carried by the beam.

  18. Download this PDF file

    African Journals Online (AJOL)

    andrew

    neck of the radius by dividing into ulnar and radial arter- ies (1). Variations .... B: Proximal third arm bifurcation of the BrA (single red circle), HH is the head of the humerus while .... artery: embryology, case report and clinical significance in.

  19. Total carpometacarpal joint dislocation combined with trapezium fracture, trapezoid dislocation and hamate fracture

    DEFF Research Database (Denmark)

    Gvozdenovic, R; Vadstrup, Lars Soelberg

    2015-01-01

    and resulted from rupture of both transverse and longitudinal carpal columns. According to the Garcia-Elias classification of axial carpal disruptions, this particular injury mechanism was a combined axial-radial-ulnar type injury. These injuries are extremely rare and are only sporadically described...

  20. Antiproton compression and radial measurements

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Funakoshi, R; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jenkins, M J; Jorgensen, L V; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Page R D; Povilus, A; Pusa, P; Robicheaux, F; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; Van der Werf, D P; Wurtele, J S; Yamazaki, Y

    2008-01-01

    Control of the radial profile of trapped antiproton clouds is critical to trapping antihydrogen. We report detailed measurements of the radial manipulation of antiproton clouds, including areal density compressions by factors as large as ten, achieved by manipulating spatially overlapped electron plasmas. We show detailed measurements of the near-axis antiproton radial profile, and its relation to that of the electron plasma. We also measure the outer radial profile by ejecting antiprotons to the trap wall using an octupole magnet.

  1. Imagens ultra-sonográficas do plexo braquial na região axilar Imágenes ultra-sonográficas del plexo braquial en la región axilar Ultrasound images of the brachial plexus in the axillary region

    Directory of Open Access Journals (Sweden)

    Diogo Brüggemann da Conceição

    2007-12-01

    Full Text Available JUSTIFICATIVA E OBJETIVOS: A artéria axilar é referência anatômica de superfície para o bloqueio do plexo braquial por via axilar. Estudos anatômicos sugerem variabilidade das posições das estruturas nervosas do plexo braquial em relação à artéria. Essas variações podem dificultar bloqueios por neuroestimulação. A ultra-sonografia permite a identificação das estruturas do plexo braquial ¹. Este estudo visou a descrever o posicionamento dos nervos do plexo braquial em relação à artéria axilar. MÉTODO: Foram estudados 30 voluntários de ambos os sexos, em posição supina com abdução a 90º e rotação externa do ombro e flexão do cotovelo a 90º. Utilizando transdutor digital de 5 cm e 5-10 MHz, foram identificados os nervos mediano, ulnar e radial e as respectivas posições em relação à artéria foram marcadas em uma carta gráfica seccional de oito setores, numerados em ordem crescente a partir da hora 12 (medial, cujo centro representava a artéria axilar. RESULTADOS: O nervo mediano localizou-se predominante no setor 8 (55% e no setor 1 (28% (mediais; o nervo radial localizou-se predominantemente nos setores 4 (59% e 5 (34% (laterais e o nervo ulnar nos setores 2 e 3 (inferiores em 69% e 24% dos casos, respectivamente. Houve considerável variação da localização dos nervos em relação aos aspectos superior e inferior da artéria. CONCLUSÕES: A inspeção em tempo real, por ultra-som, das estruturas neurovasculares do plexo braquial na axila mostrou que os nervos mediano, ulnar e radial podem apresentar diferentes relações com a artéria axilar.JUSTIFICATIVA Y OBJETIVOS: La arteria axilar es una referencia anatómica de superficie para el bloqueo del plexo braquial por vía axilar. Estudios anatómicos sugieren variabilidad de las posiciones de las estructuras nerviosas del plexo braquial con relación a la arteria. Esas variaciones pueden dificultar bloqueos por neuro estimulación. El ultrasonido

  2. MRI of fractures of the distal radius: comparison with conventional radiographs

    International Nuclear Information System (INIS)

    Spence, L.D.; Eustace, S.

    1998-01-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.)

  3. MRI of fractures of the distal radius: comparison with conventional radiographs

    Energy Technology Data Exchange (ETDEWEB)

    Spence, L.D.; Eustace, S. [Medical Center, Boston, MA (United States). Dept. of Radiol.; Savenor, A.; Nwachuku, I.; Tilsley, J. [Department of Orthopedics, Boston Medical Center, Boston, MA 02118 (United States)

    1998-05-01

    Objective. To compare the evaluation of fractures of the distal radius with MRI and conventional radiographs. To demonstrate the ability of MRI to detect unsuspected soft tissue derangement accompanying this common injury. Design and patients. Twenty-one consecutive inpatients admitted following fracture of the distal radius underwent preoperative evaluation with both conventional radiographs and MRI. In each case, analysis was made of both the osseous and soft tissue injury. MRI findings were compared with those identified on conventional radiographs and at subsequent surgical fixation. Results. Of 21 patients with fractures of the distal radius, 20 had extension to the radiocarpal articulation, 14 had distal radio-ulnar joint extension and 5 had avulsion of the ulnar styloid.Occult carpal bone fractures accompanying fracture of the distal radius were identified in two patients: one of the capitate and the other of the second metacarpal base. Ten patients (48%) had associated soft tissue injury: six patients had scapholunate ligament rupture, two patients had disruption of the triangular fibrocartilage, one patient had extensor carpi ulnaris tenosynovitis and one patient had a tear of a dorsal radiocarpal ligament. Of five patients with ulnar styloid avulsions, none had evidence of triangular fibrocartilage tears. Conclusion. MRI affords better evaluation of osseous injury accompanying distal radial fractures than conventional radiographs. Intra-articular soft tissue injury accompanies distal radial fractures in almost 50% of cases. Scapholunate ligament disruption commonly accompanies intra-articular fracture through the lunate facet of the distal radius. Fracture of the ulnar styloid is infrequently associated with tear of the triangular fibrocartilage. (orig.) With 5 figs., 16 refs.

  4. Tratamento da síndrome do túnel ulnar pela técnica da epicondilectomia parcial medial do cotovelo Treatment of cubital tunnel syndrome using the technique of medial partial epicondylectomy of the elbow

    Directory of Open Access Journals (Sweden)

    Marcio Eduardo de Melo Viveiros

    2008-12-01

    Full Text Available OBJETIVO: Analisamos retrospectivamente os resultados de 21 casos de síndrome cubital tratados cirurgicamente com a técnica da epicondilectomia parcial medial. MÉTODOS: No período de fevereiro de 2001 a outubro de 2006, 21 pacientes com síndrome do canal cubital foram tratados pela técnica da epicondilectomia parcial medial do cotovelo associada à neurólise do nervo ulnar. Destes, 12 (57,1% eram do sexo masculino. O lado direito foi o acometido em 15 (71,4% pacientes. A média da idade dos pacientes foi de 51,6 anos. Pela graduação de McGowan, seis (28,6% pacientes encontravam-se no grau I, 11 (52,3%, no grau II e quatro (19,1%, no grau III do período pré-operatório. RESULTADOS: O tempo médio de acompanhamento pós-operatório foi de 25,7 meses. No pós-operatório, os pacientes foram avaliados conforme a escala de pontos de Bishop, sendo que nove (42,8% apresentavam resultados excelentes, sete (33,3%, bons, três (14,2%, regulares e dois (9,5%, ruins. Nesta série, não se encontraram como complicações a instabilidade em valgo residual, a lesão permanente do nervo ulnar, a recidiva da compressão ou a subluxação do nervo ulnar. As complicações encontradas foram perda do arco de movimento em um (4,7% caso, infecção superficial em um (4,7% e um (4,7% com dor residual. CONCLUSÃO: Os resultados apresentados permitem concluir que a epicondilectomia parcial medial do cotovelo associada à neurólise do nervo ulnar é eficiente e segura para o tratamento da síndrome do canal cubital.OBJECTIVE: The authors made a retrospective analysis of the results of 21 cases of cubital syndrome that were surgically treated with the partial medial epicondylectomy. METHODS: From February 2001 to October 2006, 21 patients with cubital tunnel syndrome were treated with the technique of elbow partial medial epicondylectomy associated to neurolysis of the ulnar nerve. Of these patients, 12 (57.1% were male. The right side was involved in 15 (71

  5. AngularJS Performance: A Survey Study

    OpenAIRE

    Ramos, Miguel; Valente, Marco Tulio; Terra, Ricardo

    2017-01-01

    AngularJS is a popular JavaScript MVC-based framework to construct single-page web applications. In this paper, we report the results of a survey with 95 professional developers about performance issues of AngularJS applications. We report common practices followed by developers to avoid performance problems (e.g., use of third-party or custom components), the general causes of performance problems in AngularJS applications (e.g., inadequate architecture decisions taken by AngularJS users), a...

  6. Angular Positioning Sensor for Space Mechanisms

    Science.gov (United States)

    Steiner, Nicolas; Chapuis, Dominique

    2013-09-01

    Angular position sensors are used on various rotating mechanisms such as solar array drive mechanisms, antenna pointing mechanisms, scientific instruments, motors or actuators.Now a days, potentiometers and encoders are mainly used for angular measurement purposes. Both of them have their own pros and cons.As alternative, Ruag Space Switzerland Nyon (RSSN) is developing and qualifying two innovative technologies of angular position sensors which offer easy implementation, medium to very high lifetime and high flexibility with regards to the output signal shape/type.The Brushed angular position sensor uses space qualified processes which are already flying on RSSN's sliprings for many years. A large variety of output signal shape can be implemented to fulfill customer requirements (digital, analog, customized, etc.).The contactless angular position sensor consists in a new radiation hard Application Specific Integrated Circuit (ASIC) based on the Hall effect and providing the angular position without complex processing algorithm.

  7. Utilization of the bicipital groove axis for confirming alignment of the humerus with transepicondylar and ulnar shaft axes during intramedullary nailing.

    Science.gov (United States)

    Meriç, Gökhan; Zeybek, Gülşah; Kıray, Amaç; Atik, Aziz; Budeyri, Aydın; Koşay, Can

    2015-01-01

    Intramedullary nailing is the preferred surgical treatment of humerus shaft fractures. The purpose of this study was to investigate the relationship between the bicipital groove and specific anatomical landmarks in achieving correct alignment of the humerus during intramedullary nailing, and to describe these anatomical landmarks. Thirty (15 right; 15 left) total upper cadaver extremities were used in this study. After the anatomical landmarks were identified and marked, humeral head axis, transepicondylar axis, ulnar shaft axis, bicipital groove axis, and angular measurements of these were obtained. The mean angle between the bicipital groove axis and transepicondylar axis was 48.17°±12.35º (range: 20.10º to 74.6º). The mean angle between the bicipital groove axis and ulna diaphysis axis was 41.82º±11.56 º (range: 17.91º to 68.27º). The mean angle between the humeral head axis and bicipital groove axis was 20.53°±3.90º (range: 11.85º to 31.81º). The mean retroversion angle between the humeral head axis and transepicondylar axis was 27.52±11.37º (range: 4.26º to 49.36º). The mean angle between the humeral head axis and ulna diaphysis axis was 61.73º±12.08º (range: 33.97º to 86.37º). The mean torsion angle was 62.58º±11.28 º (range: 40.74º to 85.74º). Measurement and utilization of the relationship between the bicipital groove, ulna diaphysis and transepicondylar axes may be used for restoring humeral rotation.

  8. Instant AngularJS starter

    CERN Document Server

    Menard, Dan

    2013-01-01

    Get to grips with a new technology, understand what it is and what it can do for you, and then get to work with the most important features and tasks. This book is written in an easytoread style, with a strong emphasis on realworld, practical examples. Stepbystep explanations are provided for performing important tasks.This book is for web developers familiar with JavascriptIt doesn't cover the history of AngularJS, and it's not a pitch to convince you that AngularJS is the best framework on the entire web. It's a guide to help you learn everything you need to know about AngularJS in as few pa

  9. AngularJS testing cookbook

    CERN Document Server

    Bailey, Simon

    2015-01-01

    This book is intended for developers who have an understanding of the basic principles behind both AngularJS and test-driven development. You, as a developer, are interested in eliminating the fear related to either introducing tests to an existing codebase or starting out testing on a fresh AngularJS application. If you're a team leader or part of a QA team with the responsibility of ensuring full test coverage of an application, then this book is ideal for you to comprehend the full testing scope required by your developers. Whether you're new to or are well versed with AngularJS, this book

  10. Stability of radial swirl flows

    International Nuclear Information System (INIS)

    Dou, H S; Khoo, B C

    2012-01-01

    The energy gradient theory is used to examine the stability of radial swirl flows. It is found that the flow of free vortex is always stable, while the introduction of a radial flow will induce the flow to be unstable. It is also shown that the pure radial flow is stable. Thus, there is a flow angle between the pure circumferential flow and the pure radial flow at which the flow is most unstable. It is demonstrated that the magnitude of this flow angle is related to the Re number based on the radial flow rate, and it is near the pure circumferential flow. The result obtained in this study is useful for the design of vaneless diffusers of centrifugal compressors and pumps as well as other industrial devices.

  11. Variation in angular velocity and angular acceleration of a particle in rectilinear motion

    International Nuclear Information System (INIS)

    Mashood, K K; Singh, V A

    2012-01-01

    We discuss the angular velocity and angular acceleration associated with a particle in rectilinear motion with constant acceleration. The discussion was motivated by an observation that students and even teachers have difficulty in ascribing rotational motion concepts to a particle when the trajectory is a straight line. We present some details of our observations. A formal derivation of ω and α is presented which reveals ‘surprising’ and non-intuitive aspects, namely non-monotonic behaviour with an associated extremum. The special case of constant velocity is studied and we find that angular acceleration associated with it also has an extremum. We discuss a plausible source of difficulty. (paper)

  12. Fission fragment angular momentum

    International Nuclear Information System (INIS)

    Frenne, D. De

    1991-01-01

    Most of the energy released in fission is converted into translational kinetic energy of the fragments. The remaining excitation energy will be distributed among neutrons and gammas. An important parameter characterizing the scission configuration is the primary angular momentum of the nascent fragments. Neutron emission is not expected to decrease the spin of the fragments by more than one unit of angular momentum and is as such of less importance in the determination of the initial fragment spins. Gamma emission is a suitable tool in studying initial fragment spins because the emission time, number, energy, and multipolarity of the gammas strongly depend on the value of the primary angular momentum. The main conclusions of experiments on gamma emission were that the initial angular momentum of the fragments is large compared to the ground state spin and oriented perpendicular to the fission axis. Most of the recent information concerning initial fragment spin distributions comes from the measurement of isomeric ratios for isomeric pairs produced in fission. Although in nearly every mass chain isomers are known, only a small number are suitable for initial fission fragment spin studies. Yield and half-life considerations strongly limit the number of candidates. This has the advantage that the behavior of a specific isomeric pair can be investigated for a number of fissioning systems at different excitation energies of the fragments and fissioning nuclei. Because most of the recent information on primary angular momenta comes from measurements of isomeric ratios, the global deexcitation process of the fragments and the calculation of the initial fragment spin distribution from measured isomeric ratios are discussed here. The most important results on primary angular momentum determinations are reviewed and some theoretical approaches are given. 45 refs., 7 figs., 2 tabs

  13. Angular Acceleration without Torque?

    Science.gov (United States)

    Kaufman, Richard D.

    2012-01-01

    Hardly. Just as Robert Johns qualitatively describes angular acceleration by an internal force in his article "Acceleration Without Force?" here we will extend the discussion to consider angular acceleration by an internal torque. As we will see, this internal torque is due to an internal force acting at a distance from an instantaneous center.

  14. [Comparison of chemical quality characteristics between radial striations and non-radial striations in tuberous root of Rehmannia glutinosa].

    Science.gov (United States)

    Xie, Cai-Xia; Zhang, Miao; Li, Ya-Jing; Geng, Xiao-Tong; Wang, Feng-Qing; Zhang, Zhong-Yi

    2017-11-01

    An HPLC method was established to determine the contents of catalpol, acteoside, rehmaionoside A, rehmaionoside D, leonuride in three part of Rehmanni glutinosa in Beijing No.1 variety R. glutinosa during the growth period, This method, in combination with its HPLC fingerprint was used to evaluate its overall quality characteristics.The results showed that:① the content of main components of R. glutinosa varied in different growth stages ;② there was a great difference of the content of main components between theradial striations and the non-radial striations; ③ the two sections almost have the same content distribution of catalpol, acteoside and rehmaionoside D; ④the content of rehmaionoside A in non-radial striations was higher than that in radial striations,while the content of leonuride in radial striations was higher than that in non-radial striations.; ⑤the HPLC fingerprint of radial striations, non-radial striations and whole root tuber were basically identical, except for the big difference in the content of chemical components. The result of clustering displayed that the radial striations, non-radial striations, and whole root were divided into two groups. In conclusion, there was a significant difference in the quality characteristics of radial striations and non-radial striations of R. glutinosa. This research provides a reference for quality evaluation and geoherbalism of R. glutinosa. Copyright© by the Chinese Pharmaceutical Association.

  15. What can we learn about heavy ion fusion by studying fission angular distributions

    International Nuclear Information System (INIS)

    Back, B.B.

    1984-01-01

    Determinations of complete fusion reactions leading to fissionable systems are associated with problems of separating fragments from quasi-fission reactions from those arising from fission of the completely fused system. Inferring complete fusion cross sections from the minute cross sections for the evaporation residue channel is hampered by the insufficient knowledge of the branching ratio for neutron emission and fission in the decay sequence of the completely fused system. From a quantitative analysis of the fragment angular distributions it is, however, possible under certain assumptions to deduce the relative contribution of complete fusion and quasi-fission. It is found that the complete fusion process is hindered for heavy projectiles. The excess radial energy over the interaction barrier needed to induce fusion with heavy projectiles is determined in several cases and systematic trends are presented

  16. Clinical repercussions of Martin-Gruber anastomosis: anatomical study

    Directory of Open Access Journals (Sweden)

    Cristina Schmitt Cavalheiro

    2016-04-01

    Full Text Available OBJECTIVE: The main objective of this study was to describe Martin-Gruber anastomosis anatomically and to recognize its clinical repercussions. METHOD: 100 forearms of 50 adult cadavers were dissected in an anatomy laboratory. The dissection was performed by means of a midline incision along the entire forearm and the lower third of the upper arm. Two flaps including skin and subcutaneous tissue were folded back on the radial and ulnar sides, respectively. RESULTS: Nerve communication between the median and ulnar nerves in the forearm (Martin-Gruber anastomosis was found in 27 forearms. The anastomosis was classified into six types: type I: anastomosis between the anterior interosseous nerve and the ulnar nerve (n = 9; type II: anastomosis between the anterior interosseous nerve and the ulnar nerve at two points (double anastomosis (n = 2; type III: anastomosis between the median nerve and the ulnar nerve (n = 4; type IV: anastomosis between branches of the median nerve and ulnar nerve heading toward the flexor digitorum profundus muscle of the fingers; these fascicles form a loop with distal convexity (n = 5; type V: intramuscular anastomosis (n = 5; and type VI: anastomosis between a branch of the median nerve to the flexor digitorum superficialis muscle and the ulnar nerve (n = 2. CONCLUSION: Knowledge of the anatomical variations relating to the innervation of the hand has great importance, especially with regard to physical examination, diagnosis, prognosis and surgical treatment. If these variations are not given due regard, errors and other consequences will be inevitable.

  17. Angular-momentum transport in nuclear collisions

    International Nuclear Information System (INIS)

    Wolschin, G.; Ayik, S.; Noerenberg, W.

    1978-01-01

    Among the various relaxation processes that can be observed in heavy-ion collisions, the dissipation of relative angular momentum into intrinsic angular momentum of the fragments attracts increasing attention. Here we present a transport theoretical description of angular-momentum and mass transport that allows for a transparent interpretation of the data. (orig.) [de

  18. AngularJS test-driven development

    CERN Document Server

    Chaplin, Tim

    2015-01-01

    This book is for developers who want to learn about AngularJS development by applying testing techniques. You are assumed to have a basic knowledge and understanding of HTML, JavaScript, and AngularJS.

  19. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    Science.gov (United States)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was

  20. Physical mechanism determining the radial electric field and its radial structure in a toroidal plasma

    International Nuclear Information System (INIS)

    Ida, Katsumi; Miura, Yukitoshi; Itoh, Sanae

    1994-10-01

    Radial structures of plasma rotation and radial electric field are experimentally studied in tokamak, heliotron/torsatron and stellarator devices. The perpendicular and parallel viscosities are measured. The parallel viscosity, which is dominant in determining the toroidal velocity in heliotron/torsatron and stellarator devices, is found to be neoclassical. On the other hand, the perpendicular viscosity, which is dominant in dictating the toroidal rotation in tokamaks, is anomalous. Even without external momentum input, both a plasma rotation and a radial electric field exist in tokamaks and heliotrons/torsatrons. The observed profiles of the radial electric field do not agree with the theoretical prediction based on neoclassical transport. This is mainly due to the existence of anomalous perpendicular viscosity. The shear of the radial electric field improves particle and heat transport both in bulk and edge plasma regimes of tokamaks. (author) 95 refs

  1. Upper limb artery segmental occlusions due to chronic use of ergotamine combined with itraconazole, treated by thrombolysis

    Directory of Open Access Journals (Sweden)

    Nodari Franco

    2011-08-01

    Full Text Available Abstract Background The ergotamine tartrate associated with certain categories of drugs can lead to critical ischemia of the extremities. Discontinuation of taking ergotamine is usually sufficient for the total regression of ischemia, but in some cases it could be necessary thrombolytic and anticoagulant therapy to avoid amputation. Case report A woman of 62 years presented with a severe pain left forearm appeared 10 days ago, with a worsening trend. The same symptoms appeared after 5 days also in the right forearm. Physical examination showed the right arm slightly hypothermic, with radial reduced pulse in presence of reduced sensitivity. The left arm was frankly hypothermic, pulse less on radial and with an ulnar humeral reduced pulse, associated to a decreased sensitivity and motility. Clinical history shows a chronic headache for which the patient took a daily basis for years Cafergot suppository (equivalent to 3.2 mg of ergotamine. From about ten days had begun therapy with itraconazole for vaginal candidiasis. The Color-Doppler ultrasound shown arterial thrombosis of the upper limbs (humeral and radial bilateral, with minimal residual flow to the right and no signal on the humeral and radial left artery. Results Angiography revealed progressive reduction in size of the axillary artery and right humeral artery stenosis with right segmental occlusions and multiple hypertrophic collateral circulations at the elbow joint. At the level of the right forearm was recognizable only the radial artery, decreased in size. Does not recognize the ulnar, interosseous artery was thin. To the left showed progressive reduction in size of the distal subclavian and humeral artery, determined by multiple segmental steno-occlusion with collateral vessels serving only a thin hypotrophic interosseous artery. Arteriographic findings were compatible with systemic drug-induced disease. The immediate implementation of thrombolysis, continued for 26 hours, with

  2. Angular momentum from tidal torques

    International Nuclear Information System (INIS)

    Barnes, J.; Efstathiou, G.; Cambridge Univ., England)

    1987-01-01

    The origin of the angular momentum of bound objects in large N-body simulations is studied using three sets of models. One model with white-noise initial conditions is analyzed as well as two in which the initial conditions have more power on large scales, as predicted in models with cold dark matter. The growth and distribution of angular momentum in individual objects is studied and it is found that the specific angular momentum distribution of bound clumps increases in a near linear fashion with radius while the orientation of the angular momentum in the inner high-density regions is often poorly correlated with that of the outer parts. It is also found that the dimensionless spin parameter is insensitive to the initial perturbation spectrum and has a median value of about 0.05. 61 references

  3. Transverse and longitudinal angular momenta of light

    Energy Technology Data Exchange (ETDEWEB)

    Bliokh, Konstantin Y., E-mail: k.bliokh@gmail.com [Center for Emergent Matter Science, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Nonlinear Physics Centre, RSPhysE, The Australian National University, Canberra, ACT 0200 (Australia); Nori, Franco [Center for Emergent Matter Science, RIKEN, Wako-shi, Saitama 351-0198 (Japan); Physics Department, University of Michigan, Ann Arbor, MI 48109-1040 (United States)

    2015-08-26

    We review basic physics and novel types of optical angular momentum. We start with a theoretical overview of momentum and angular momentum properties of generic optical fields, and discuss methods for their experimental measurements. In particular, we describe the well-known longitudinal (i.e., aligned with the mean momentum) spin and orbital angular momenta in polarized vortex beams. Then, we focus on the transverse (i.e., orthogonal to the mean momentum) spin and orbital angular momenta, which were recently actively discussed in theory and observed in experiments. First, the recently-discovered transverse spin  angular momenta appear in various structured fields: evanescent waves, interference fields, and focused beams. We show that there are several kinds of transverse spin angular momentum, which differ strongly in their origins and physical properties. We describe extraordinary features of the transverse optical spins and overview recent experiments. In particular, the helicity-independent transverse spin inherent in edge evanescent waves offers robust spin–direction coupling at optical interfaces (the quantum spin Hall effect of light). Second, we overview the transverse orbital angular momenta of light, which can be both extrinsic and intrinsic. These two types of the transverse orbital angular momentum are produced by spatial shifts of the optical beams (e.g., in the spin Hall effect of light) and their Lorentz boosts, respectively. Our review is underpinned by a unified theory of the angular momentum of light based on the canonical momentum and spin densities, which avoids complications associated with the separation of spin and orbital angular momenta in the Poynting picture. It allows us to construct a comprehensive classification of all known optical angular momenta based on their key parameters and main physical properties.

  4. Stability of dislocation structures in copper towards stress relaxation investigated by high angular resolution 3D X-ray diffraction

    DEFF Research Database (Denmark)

    Jakobsen, Bo; Poulsen, Henning Friis; Lienert, Ulrich

    2009-01-01

    A 300 µm thick tensile specimen of OFHC copper is subjected to a tensile loading sequence and deformed to a maximal strain of 3.11%. Using the novel three-dimensional X-ray diffraction method High angular resolution 3DXRD', the evolution of the microstructure within a deeply embedded grain....... In contrast to the deformation stages, during each stress relaxation stage, number, size and orientation of subgrains are found to be constant, while a minor amount of clean-up of the microstructure is observed as narrowing of the radial X-ray diffraction line profile. The associated decrease in the width...

  5. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  6. Strong non-radial propagation of energetic electrons in solar corona

    Science.gov (United States)

    Klassen, A.; Dresing, N.; Gómez-Herrero, R.; Heber, B.; Veronig, A.

    2018-06-01

    Analyzing the sequence of solar energetic electron events measured at both STEREO-A (STA) and STEREO-B (STB) spacecraft during 17-21 July 2014, when their orbital separation was 34°, we found evidence of a strong non-radial electron propagation in the solar corona below the solar wind source surface. The impulsive electron events were associated with recurrent flare and jet (hereafter flare/jet) activity at the border of an isolated coronal hole situated close to the solar equator. We have focused our study on the solar energetic particle (SEP) event on 17 July 2014, during which both spacecraft detected a similar impulsive and anisotropic energetic electron event suggesting optimal connection of both spacecraft to the parent particle source, despite the large angular separation between the parent flare and the nominal magnetic footpoints on the source surface of STA and STB of 68° and 90°, respectively. Combining the remote-sensing extreme ultraviolet (EUV) observations, in-situ plasma, magnetic field, and energetic particle data we investigated and discuss here the origin and the propagation trajectory of energetic electrons in the solar corona. We find that the energetic electrons in the energy range of 55-195 keV together with the associated EUV jet were injected from the flare site toward the spacecraft's magnetic footpoints and propagate along a strongly non-radial and inclined magnetic field below the source surface. From stereoscopic (EUV) observations we estimated the inclination angle of the jet trajectory and the respective magnetic field of 63° ± 11° relative to the radial direction. We show how the flare accelerated electrons reach very distant longitudes in the heliosphere, when the spacecraft are nominally not connected to the particle source. This example illustrates how ballistic backmapping can occasionally fail to characterize the magnetic connectivity during SEP events. This finding also provides an additional mechanism (one among others

  7. Angular trap for macroparticles

    International Nuclear Information System (INIS)

    Aksyonov, D.S.

    2013-01-01

    Properties of angular macroparticle traps were investigated in this work. These properties are required to design vacuum arc plasma filters. The correlation between trap geometry parameters and its ability to absorb macroparticles were found. Calculations allow one to predict the behaviour of filtering abilities of separators which contain such traps in their design. Recommendations regarding the use of angular traps in filters of different builds are given.

  8. Radial retinotomy in the macula.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-01-01

    Radial retinotomy is an operative procedure usually performed in the peripheral or equatorial retina. To facilitate retinal attachment, the authors used intraocular scissors to perform radial retinotomy in the macula of two patients during vitrectomy surgery. In the first patient, a retinal detachment complicated by periretinal proliferation and macula hole formation was successfully reoperated with the aid of three radial cuts in the retina at the edges of the macular hole. In the second patient, an intraoperative retinal tear in the macula during diabetic vitrectomy was also successfully repaired with the aid of radial retinotomy. In both patients, retinotomy in the macula was required because epiretinal membranes, which could not be easily delaminated, were hindering retinal reattachment.

  9. Radial head dislocation during proximal radial shaft osteotomy.

    Science.gov (United States)

    Hazel, Antony; Bindra, Randy R

    2014-03-01

    The following case report describes a 48-year-old female patient with a longstanding both-bone forearm malunion, who underwent osteotomies of both the radius and ulna to improve symptoms of pain and lack of rotation at the wrist. The osteotomies were templated preoperatively. During surgery, after performing the planned radial shaft osteotomy, the authors recognized that the radial head was subluxated. The osteotomy was then revised from an opening wedge to a closing wedge with improvement of alignment and rotation. The case report discusses the details of the operation, as well as ways in which to avoid similar shortcomings in the future. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  10. Angular momentum in general relativity

    International Nuclear Information System (INIS)

    Cresswell, A.; Zimmerman, R.L.; Oregon Univ., Eugene

    1986-01-01

    It is argued that the correct expressions for the angular momentum flux carried by gravitational radiation should follow directly from the momentum currents. Following this approach, the authors compute the angular momentum associated with several different choices of energy-momentum prescriptions. (author)

  11. Radial cracks and fracture mechanism of radially oriented ring 2:17 type SmCo magnets

    International Nuclear Information System (INIS)

    Tian Jianjun; Pan Dean; Zhou Hao; Yin Fuzheng; Tao Siwu; Zhang Shengen; Qu Xuanhui

    2009-01-01

    Radially oriented ring 2:17 type SmCo magnets have different microstructure in the radial direction (easy magnetization) and axial direction (hard magnetization). The structure of the cross-section in radial direction is close-packed atomic plane, which shows cellular microstructure. The microstructure of the cross-section in axial direction consists of a mixture of rhombic microstructure and parallel lamella phases. So the magnets have obvious anisotropy of thermal expansion in different directions. The difference of the thermal expansion coefficients reaches the maximum value at 830-860 deg. C, which leads to radial cracks during quenching. The magnets have high brittlement because there are fewer slip systems in crystal structure. The fracture is brittle cleavage fracture.

  12. Trauma and sports injuries of the elbow

    NARCIS (Netherlands)

    Kodde, I.F.

    2016-01-01

    This thesis deals with current issues in the management of trauma and sports injuries of the elbow. Common sports injuries of the elbow involve ruptures of the distal biceps tendon and the ulnar collateral ligament. We evaluated one of the current thoughts, that the height of the radial bicipital

  13. [Improving diagnosis and treatment of tunnel upper limb neuropathies in miners with vibration disease].

    Science.gov (United States)

    Kir'ianov, V A; Zheglova, A V; Aliev, A F; Krylova, I V; Sukhova, A V

    2011-01-01

    The article presents results of research aimed to diagnosis and treatment of tunnel upper limb neuropathies in mining industry workers subjected to vibration factor. The authors specified diagnostic criteria for early diagnosis of tunnel neuropathies affecting median, ulnar and radial nerves, with the severity evaluation for further adequate treatment.

  14. Sex differences in fingerprint ridge density in a Turkish young adult population: a sample of Baskent University.

    Science.gov (United States)

    Oktem, Hale; Kurkcuoglu, Ayla; Pelin, Ismail Can; Yazici, Ayse Canan; Aktaş, Gulnihal; Altunay, Fikret

    2015-05-01

    Fingerprints are considered to be one of the most reliable methods of identification. Identification of an individual plays a vital part of any medico-legal investigations. Dermatoglyphics is a branch of science that studies epidermal ridges and ridge patterns. Epidermal ridges are polygenic characteristics that form intrauterine 10-18 weeks and considered fully developed by the sixth month of fetal growth. Fingerprints are permanent morphological characteristics and criminal detection based on fingerprints is based on the principle that no two people can have identical fingerprints. Sex determination from fingerprints has been examined in different population. In this study we aimed to study fingerprint ridge density in Turkish population sample of Baskent University students. Fingerprints were obtained from 118 women, 88 men a total of 206 students aged between 17 and 28 years old by means of simple inking method. Fingerprints from all right and left hands fingers were collected in three different area of each. The ridges on fingerprints were counted diagonally on squares measuring 5 mm × 5 mm on radial, ulnar and inferior areas. The fingerprint ridge density in radial, ulnar and inferior areas and between sexes was compared statistically Mann Whitney U test and Friedman test. The ridge density was significantly greater in women in every region studied and in all fingers when compared to men. The fingerprint ridge density in the ulnar and radial areas of the fingerprints was significantly greater than the lower area. Fingerprint ridge density can be used by medico-legal examination for sex identification. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  15. High-dimensional orbital angular momentum entanglement concentration based on Laguerre–Gaussian mode selection

    International Nuclear Information System (INIS)

    Zhang, Wuhong; Su, Ming; Wu, Ziwen; Lu, Meng; Huang, Bingwei; Chen, Lixiang

    2013-01-01

    Twisted photons enable the definition of a Hilbert space beyond two dimensions by orbital angular momentum (OAM) eigenstates. Here we propose a feasible entanglement concentration experiment, to enhance the quality of high-dimensional entanglement shared by twisted photon pairs. Our approach is started from the full characterization of entangled spiral bandwidth, and is then based on the careful selection of the Laguerre–Gaussian (LG) modes with specific radial and azimuthal indices p and ℓ. In particular, we demonstrate the possibility of high-dimensional entanglement concentration residing in the OAM subspace of up to 21 dimensions. By means of LabVIEW simulations with spatial light modulators, we show that the Shannon dimensionality could be employed to quantify the quality of the present concentration. Our scheme holds promise in quantum information applications defined in high-dimensional Hilbert space. (letter)

  16. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    Science.gov (United States)

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  17. THE MEGAMASER COSMOLOGY PROJECT. V. AN ANGULAR-DIAMETER DISTANCE TO NGC 6264 AT 140 Mpc

    International Nuclear Information System (INIS)

    Kuo, C. Y.; Braatz, J. A.; Lo, K. Y.; Condon, J. J.; Impellizzeri, C. M. V.; Reid, M. J.; Henkel, C.

    2013-01-01

    We present the direct measurement of the Hubble constant, yielding the direct measurement of the angular-diameter distance to NGC 6264 using the H 2 O megamaser technique. Our measurement is based on sensitive observations of the circumnuclear megamaser disk from four observations with the Very Long Baseline Array, the Green Bank Telescope (GBT), and the Effelsberg telescope. We also monitored the maser spectral profile for 2.3 years using the GBT to measure accelerations of maser lines by tracking their line-of-sight velocities as they change with time. The measured accelerations suggest that the systemic maser spots have a significantly wider radial distribution than in the archetypal megamaser in NGC 4258. We model the maser emission as arising from a circumnuclear disk with orbits dominated by the central black hole. The best fit of the data gives a Hubble constant of H 0 = 68 ± 9 km s –1 Mpc –1 , which corresponds to an angular-diameter distance of 144 ± 19 Mpc. In addition, the fit also gives a mass of the central black hole of (3.09 ± 0.42) × 10 7 M ☉ . The result demonstrates the feasibility of measuring distances to galaxies located well into the Hubble flow by using circumnuclear megamaser disks.

  18. Orbital angular momentum in phase space

    International Nuclear Information System (INIS)

    Rigas, I.; Sanchez-Soto, L.L.; Klimov, A.B.; Rehacek, J.; Hradil, Z.

    2011-01-01

    Research highlights: → We propose a comprehensive Weyl-Wigner formalism for the canonical pair angle-angular momentum. → We present a simple and useful toolkit for the practitioner. → We derive simple evolution equations in terms of a star product in the semiclassical limit. - Abstract: A comprehensive theory of the Weyl-Wigner formalism for the canonical pair angle-angular momentum is presented. Special attention is paid to the problems linked to rotational periodicity and angular-momentum discreteness.

  19. Perceived radial translation during centrifugation

    NARCIS (Netherlands)

    Bos, J.E.; Correia Grácio, B.J.

    2015-01-01

    BACKGROUND: Linear acceleration generally gives rise to translation perception. Centripetal acceleration during centrifugation, however, has never been reported giving rise to a radial, inward translation perception. OBJECTIVE: To study whether centrifugation can induce a radial translation

  20. Angular momentum projected wave-functions

    International Nuclear Information System (INIS)

    Bengtsson, R.; Haakansson, H.B.

    1978-01-01

    Angular momentum projection has become a vital link between intrinsic model-wavefunctions and the physical states one intends to describe. We discuss in general terms some aspects of angular momentum projection and present results from projection on e.g. cranking wavefunctions. Mass densities and spectroscopic factors are also presented for some cases. (author)

  1. Self-consistent radial sheath

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1988-12-01

    The boundary layer arising in the radial vicinity of a tokamak limiter is examined, with special reference to the TEXT tokamak. It is shown that sheath structure depends upon the self-consistent effects of ion guiding-center orbit modification, as well as the radial variation of E /times/ B-induced toroidal rotation. Reasonable agreement with experiment is obtained from an idealized model which, however simplified, preserves such self-consistent effects. It is argued that the radial sheath, which occurs whenever confining magnetic field-lines lie in the plasma boundary surface, is an object of some intrinsic interest. It differs from the more familiar axial sheath because magnetized charges respond very differently to parallel and perpendicular electric fields. 11 refs., 1 fig

  2. Differential saturation study of radial and angular modulation mechanisms of electron spin--lattice relaxation for trapped hydrogen atoms in sulfuric acid glasses. [X radiation

    Energy Technology Data Exchange (ETDEWEB)

    Plonka, A; Kevan, L

    1976-11-01

    A differential ESR saturation study of allowed transitions and forbidden proton spin-flip satellite transitions for trapped hydrogen atoms in sulfuric acid glasses indicates that angular modulation dominates the spin-lattice relaxation mechanisms and suggests that the modulation arises from motion of the H atom.

  3. Arthroscopically assisted reconstruction of triangular fibrocartilage complex foveal avulsion in the ulnar variance-positive patient.

    Science.gov (United States)

    Kim, ByungSung; Yoon, Hong-Kee; Nho, Jae-Hwi; Park, Kang Hee; Park, Sung-Yong; Yoon, Jun-Hee; Song, Hyun Seok

    2013-11-01

    Our aim was to evaluate the clinical results of patients treated by arthroscopically assisted reconstruction of foveal avulsion injury of the triangular fibrocartilage complex (TFCC) using a suture anchor. We retrospectively reviewed the results of 15 patients (11 men and 4 women; mean age, 30.5 years) who underwent surgical procedures for the treatment of TFCC foveal avulsion at our hospital. The patients were followed up for a mean of 29 months. The patients had TFCC foveal avulsion caused by sprains (n = 8), falls (n = 4), playing baseball (n = 2), and a motor vehicle accident (n = 1). All the patients underwent magnetic resonance imaging. Radiographs obtained to assess ulnar variance (UV), ulnar-dorsal subluxation, and function of the wrist based on grip power; Disabilities of the Arm, Shoulder and Hand score; and Mayo wrist score were examined for all patients both preoperatively and postoperatively. On preoperative magnetic resonance imaging, TFCC foveal avulsion was observed in 13 of 15 cases. The mean UV value based on preoperative simple radiographic findings was 1.7 ± 1.0 mm, and dorsal subluxation at the distal ulna improved from 2.9 ± 3.0 mm to 0.2 ± 0.9 mm (P = .017). In all cases the distal radioulnar joint instability disappeared postoperatively. Grip power (compared with the uninvolved limb) was 79.3% preoperatively and 82.9% postoperatively (P = .086). The Disabilities of the Arm, Shoulder and Hand scores were 28.4 points preoperatively and 16.6 points postoperatively (P = .061). The Mayo wrist scores were excellent in 10 cases, good in 2, and fair in 3, and the mean score improved significantly from 64 points preoperatively to 84 points postoperatively (P = .007). Arthroscopic-assisted suture anchor reattachment of the TFCC in patients with traumatic TFCC foveal avulsion can prevent or reduce distal radioulnar joint instability and reduce pain even in chronic cases with positive UV. Level IV, therapeutic case series. Copyright © 2013

  4. Management of Angular Cheilitis in children

    Directory of Open Access Journals (Sweden)

    Fajriani Fajriani

    2017-04-01

    Full Text Available Objective : Angular cheilitis is a type of oral soft tissue disease that can occur in children and adults, the condition is characterized by cracks and inflammation on both corners of the mouth. Although this disease can not cause severe disorder, it quite disturbs one's activity and physical appearance. Mild Angular cheilitis will recover itself over times. However severe conditions can cause pain and bleeding. This paper aims to inform colleagues about management of angular cheilitis in children.

  5. Management of angular cheilitis for children

    Directory of Open Access Journals (Sweden)

    Fajriani Fajriani

    2016-06-01

    Full Text Available Angular cheilitis is one type of oral soft tissue disease that can occur in both children and adults, the condition is characterized by cracks and inflammation in both corners of the mouth. Although this disease does not cause severe disruption but quite disturbing activity and also one's physical appearance. Angular cheilitis light will disappear on their own over time.Severe conditions that can cause pain and bleading. aims to give feedback on peers about managment angular cheilitis in children.

  6. High angular resolution at LBT

    Science.gov (United States)

    Conrad, A.; Arcidiacono, C.; Bertero, M.; Boccacci, P.; Davies, A. G.; Defrere, D.; de Kleer, K.; De Pater, I.; Hinz, P.; Hofmann, K. H.; La Camera, A.; Leisenring, J.; Kürster, M.; Rathbun, J. A.; Schertl, D.; Skemer, A.; Skrutskie, M.; Spencer, J. R.; Veillet, C.; Weigelt, G.; Woodward, C. E.

    2015-12-01

    High angular resolution from ground-based observatories stands as a key technology for advancing planetary science. In the window between the angular resolution achievable with 8-10 meter class telescopes, and the 23-to-40 meter giants of the future, LBT provides a glimpse of what the next generation of instruments providing higher angular resolution will provide. We present first ever resolved images of an Io eruption site taken from the ground, images of Io's Loki Patera taken with Fizeau imaging at the 22.8 meter LBT [Conrad, et al., AJ, 2015]. We will also present preliminary analysis of two data sets acquired during the 2015 opposition: L-band fringes at Kurdalagon and an occultation of Loki and Pele by Europa (see figure). The light curves from this occultation will yield an order of magnitude improvement in spatial resolution along the path of ingress and egress. We will conclude by providing an overview of the overall benefit of recent and future advances in angular resolution for planetary science.

  7. Radiofrequency encoded angular-resolved light scattering

    DEFF Research Database (Denmark)

    Buckley, Brandon W.; Akbari, Najva; Diebold, Eric D.

    2015-01-01

    The sensitive, specific, and label-free classification of microscopic cells and organisms is one of the outstanding problems in biology. Today, instruments such as the flow cytometer use a combination of light scatter measurements at two distinct angles to infer the size and internal complexity...... of cells at rates of more than 10,000 per second. However, by examining the entire angular light scattering spectrum it is possible to classify cells with higher resolution and specificity. Current approaches to performing these angular spectrum measurements all have significant throughput limitations...... Encoded Angular-resolved Light Scattering (REALS), this technique multiplexes angular light scattering in the radiofrequency domain, such that a single photodetector captures the entire scattering spectrum from a particle over approximately 100 discrete incident angles on a single shot basis. As a proof...

  8. Angular integrals in d dimensions.

    OpenAIRE

    Somogyi, G.

    2011-01-01

    We discuss the evaluation of certain d dimensional angular integrals which arise in perturbative field theory calculations. We find that the angular integral with n denominators can be computed in terms of a certain special function, the so-called H-function of several variables. We also present several illustrative examples of the general result and briefly consider some applications.

  9. Angular integrals in d dimensions

    International Nuclear Information System (INIS)

    Somogyi, Gabor

    2011-01-01

    We discuss the evaluation of certain d-dimensional angular integrals which arise in perturbative field theory calculations. We find that the angular integral with n denominators can be computed in terms of a certain special function, the so-called H-function of several variables. We also present several illustrative examples of the general result and briefly consider some applications.

  10. Angular integrals in d dimensions

    Science.gov (United States)

    Somogyi, Gábor

    2011-08-01

    We discuss the evaluation of certain d-dimensional angular integrals which arise in perturbative field theory calculations. We find that the angular integral with n denominators can be computed in terms of a certain special function, the so-called H-function of several variables. We also present several illustrative examples of the general result and briefly consider some applications.

  11. Angular momentum projected semiclassics

    International Nuclear Information System (INIS)

    Hasse, R.W.

    1986-10-01

    By using angular momentum projected plane waves as wave functions, we derive semiclassical expressions for the single-particle propagator, the partition function, the nonlocal density matrix, the single-particle density and the one particle- one hole level density for fixed angular momentum and fixed z-component or summed over the z-components. Other quantities can be deduced from the propagator. In coordinate space (r, r') the relevant quantities depend on vertical stroker - r 3 vertical stroke instead of vertical stroker - r'vertical stroke and in Wigner space (R, P) they become proportional to the angular momentum constraints δ(vertical strokeRxPvertical stroke/ℎ - l) and δ((RxP) z /ℎ - m). As applications we calculate the single-particle and one particle- one hole level densities for harmonic oscillator and Hill-Wheeler box potentials and the imaginary part of the optical potential and its volume integral with an underlying harmonic oscillator potential and a zero range two-body interaction. (orig.)

  12. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  13. Endoscopic versus open radial artery harvest and mammario-radial versus aorto-radial grafting in patients undergoing coronary artery bypass surgery

    DEFF Research Database (Denmark)

    Carranza, Christian L; Ballegaard, Martin; Werner, Mads U

    2014-01-01

    the postoperative complications will be registered, and we will evaluate muscular function, scar appearance, vascular supply to the hand, and the graft patency including the patency of the central radial artery anastomosis. A patency evaluation by multi-slice computer tomography will be done at one year...... to aorto-radial revascularisation techniques but this objective is exploratory. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01848886.Danish Ethics committee number: H-3-2012-116.Danish Data Protection Agency: 2007-58-0015/jr.n:30-0838....

  14. An Angular Leakage Correction for Modeling a Hemisphere, Using One-Dimensional Spherical Coordinates

    International Nuclear Information System (INIS)

    Schwinkendorf, K.N.; Eberle, C.S.

    2003-01-01

    A radially dependent, angular leakage correction was applied to a one-dimensional, multigroup neutron diffusion theory computer code to accurately model hemispherical geometry. This method allows the analyst to model hemispherical geometry, important in nuclear criticality safety analyses, with one-dimensional computer codes, which execute very quickly. Rapid turnaround times for scoping studies thus may be realized. This method uses an approach analogous to an axial leakage correction in a one-dimensional cylinder calculation. The two-dimensional Laplace operator was preserved in spherical geometry using a leakage correction proportional to 1/r 2 , which was folded into the one-dimensional spherical calculation on a mesh-by-mesh basis. Hemispherical geometry is of interest to criticality safety because of its similarity to piles of spilled fissile material and accumulations of fissile material in process containers. A hemisphere also provides a more realistic calculational model for spilled fissile material than does a sphere

  15. Spinal cord projections of the rat main forelimb nerves, studied by transganglionic transport of WGA-HRP and by the disappearance of acid phosphatase.

    Science.gov (United States)

    Castro-Lopes, J M; Coimbra, A

    1991-03-01

    The spinal cord projections of the 3 main forelimb nerves-median, radial and ulnar, were studied in the rat dorsal horn with transganglionic transport of wheat germ agglutinin-horseradish peroxidase (WGA-HRP), or using the disappearance of fluoride resistant acid phosphatase (FRAP) after nerve section. The projection patterns in lamina II were similar following the two procedures. The median and the radial nerve fibers projected to the medial and the intermediate thirds, respectively, of the dorsal horn lamina II in spinal cord segments C4-C8. The ulnar nerve projected to segments C6-C8 between the areas occupied by the other two nerves. The FRAP method also showed that the lateral part of lamina II, which was not filled by radial nerve fibers, received the projections from the dorsal cutaneous branches of cervical spinal nerves. In addition, FRAP disappeared from the medial end of segment T1 after skin incisions extending from the medial brachium to the axilla, which seemed due to severance of the cutaneous branchlets of the lateral anterior thoracic nerve. The FRAP procedure is thus sensitive enough to detect fibers in lamina II arising from small peripheral nerves, and may be used as an alternative to the anterograde tracing methods whenever there are no overlapping projections.

  16. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  17. Angular integrals in d dimensions

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, Gabor

    2011-01-15

    We discuss the evaluation of certain d dimensional angular integrals which arise in perturbative field theory calculations. We find that the angular integral with n denominators can be computed in terms of a certain special function, the so-called H-function of several variables. We also present several illustrative examples of the general result and briefly consider some applications. (orig.)

  18. Angular integrals in d dimensions

    International Nuclear Information System (INIS)

    Somogyi, Gabor

    2011-01-01

    We discuss the evaluation of certain d dimensional angular integrals which arise in perturbative field theory calculations. We find that the angular integral with n denominators can be computed in terms of a certain special function, the so-called H-function of several variables. We also present several illustrative examples of the general result and briefly consider some applications. (orig.)

  19. Numerical simulation of liquid-metal-flows in radial-toroidal-radial bends

    International Nuclear Information System (INIS)

    Molokov, S.; Buehler, L.

    1993-09-01

    Magnetohydrodynamic flows in a U-bend and right-angle bend are considered with reference to the radial-toroidal-radial concept of a self-cooled liquid-metal blanket. The ducts composing bends have rectangular cross-section. The applied magnetic field is aligned with the toroidal duct and perpendicular to the radial ones. At high Hartmann number the flow region is divided into cores and boundary layers of different types. The magnetohydrodynamic equations are reduced to a system of partial differential equations governing wall electric potentials and the core pressure. The system is solved numerically by two different methods. The first method is iterative with iteration between wall potential and the core pressure. The second method is a general one for the solution of the core flow equations in curvilinear coordinates generated by channel geometry and magnetic field orientation. Results obtained are in good agreement. They show, that the 3D-pressure drop of MHD flows in a U-bend is not a critical issue for blanket applications. (orig./HP) [de

  20. Ulnar nerve injury due to lateral traction device during shoulder arthroscopy: Was it avoidable?

    Directory of Open Access Journals (Sweden)

    Vivek Pandey

    2017-01-01

    Full Text Available Most of the nerve injuries reported during shoulder arthroscopy in a beach chair, or lateral position is related to inappropriate patient positioning or excess traction. The lateral decubitus position is more vulnerable for traction-related neuropraxia. The present case serves as an important lesson from an avoidable situation of “having a one track mind” of the surgical team during the arthroscopic repair of shoulder instability performed in the lateral decubitus position. The operating surgeon must supervise the appropriate positioning of the patient on operation table and adequate padding of vulnerable bony points before beginning of shoulder arthroscopy to prevent any position-related nerve injuries. This is probably the first case to illustrate an unusual cause of ulnar nerve compression particularly related to the use of an additional traction device in the arthroscopic repair of shoulder instability performed in lateral decubitus position, which has not been previously defined.

  1. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  2. Relativistic Energy Analysis of Five-Dimensional q-Deformed Radial Rosen-Morse Potential Combined with q-Deformed Trigonometric Scarf Noncentral Potential Using Asymptotic Iteration Method

    International Nuclear Information System (INIS)

    Pramono, Subur; Suparmi, A.; Cari, Cari

    2016-01-01

    We study the exact solution of Dirac equation in the hyperspherical coordinate under influence of separable q-deformed quantum potentials. The q-deformed hyperbolic Rosen-Morse potential is perturbed by q-deformed noncentral trigonometric Scarf potentials, where all of them can be solved by using Asymptotic Iteration Method (AIM). This work is limited to spin symmetry case. The relativistic energy equation and orbital quantum number equation l_D_-_1 have been obtained using Asymptotic Iteration Method. The upper radial wave function equations and angular wave function equations are also obtained by using this method. The relativistic energy levels are numerically calculated using Matlab, and the increase of radial quantum number n causes the increase of bound state relativistic energy level in both dimensions D=5 and D=3. The bound state relativistic energy level decreases with increasing of both deformation parameter q and orbital quantum number n_l.

  3. Combination of BMP-2-releasing gelatin/β-TCP sponges with autologous bone marrow for bone regeneration of X-ray-irradiated rabbit ulnar defects.

    Science.gov (United States)

    Yamamoto, Masaya; Hokugo, Akishige; Takahashi, Yoshitake; Nakano, Takayoshi; Hiraoka, Masahiro; Tabata, Yasuhiko

    2015-07-01

    The objective of this study is to evaluate the feasibility of gelatin sponges incorporating β-tricalcium phosphate (β-TCP) granules (gelatin/β-TCP sponges) to enhance bone regeneration at a segmental ulnar defect of rabbits with X-ray irradiation. After X-ray irradiation of the ulnar bone, segmental critical-sized defects of 20-mm length were created, and bone morphogenetic protein-2 (BMP-2)-releasing gelatin/β-TCP sponges with or without autologous bone marrow were applied to the defects to evaluate bone regeneration. Both gelatin/β-TCP sponges containing autologous bone marrow and BMP-2-releasing sponges enhanced bone regeneration at the ulna defect to a significantly greater extent than the empty sponges (control). However, in the X-ray-irradiated bone, the bone regeneration either by autologous bone marrow or BMP-2 was inhibited. When combined with autologous bone marrow, the BMP-2 exhibited significantly high osteoinductivity, irrespective of the X-ray irradiation. The bone mineral content at the ulna defect was similar to that of the intact bone. It is concluded that the combination of bone marrow with the BMP-2-releasing gelatin/β-TCP sponge is a promising technique to induce bone regeneration at segmental bone defects after X-ray irradiation. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Radial wave crystals: radially periodic structures from anisotropic metamaterials for engineering acoustic or electromagnetic waves.

    Science.gov (United States)

    Torrent, Daniel; Sánchez-Dehesa, José

    2009-08-07

    We demonstrate that metamaterials with anisotropic properties can be used to develop a new class of periodic structures that has been named radial wave crystals. They can be sonic or photonic, and wave propagation along the radial directions is obtained through Bloch states like in usual sonic or photonic crystals. The band structure of the proposed structures can be tailored in a large amount to get exciting novel wave phenomena. For example, it is shown that acoustical cavities based on radial sonic crystals can be employed as passive devices for beam forming or dynamically orientated antennas for sound localization.

  5. Aneurisma idiopático de artéria radial: relato de caso Idiopathic radial artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    Luiz Ernani Meira Jr.

    2011-12-01

    Full Text Available Os aneurismas da artéria radial são extremamente raros. Em sua maioria, consistem de pseudoaneurismas pós-traumáticos. Os aneurismas da artéria radial verdadeiros podem ser idiopáticos, congênitos, pós-estenóticos ou associados a patologias, tais como vasculites e doenças do tecido conjuntivo. Foi relatado um caso de aneurisma idiopático de artéria radial em uma criança de três anos, que, após completa investigação diagnóstica complementar, foi submetida à ressecção cirúrgica.Radial artery aneurysms are extremely rare. Post-traumatic pseudoaneurysms are the vast majority. True radial artery aneurysms can be idiopathic, congenital, poststenotic, or associated with some pathologies, such as vasculitis and conjunctive tissue diseases. We report a case of an idiopathic aneurysm of the radial artery in a three-year-old child who was submitted to surgical resection after a complete diagnostic approach.

  6. EXERCISE-INDUCED ARTERIAL ADAPTATIONS IN ELITE JUDO ATHLETES

    Directory of Open Access Journals (Sweden)

    Panagiotis Karagounis

    2009-09-01

    Full Text Available The purpose of this study was to examine exercise-induced arterial adaptations in elite Judo male and female athletes. 27 male Judo athletes (age 24.06 ± 2 years, 11 female Judoka (age 24.27 ± 1 years, 27 sedentary healthy men (age 24.01 ± 2 years and 11 women (age 24.21 ± 1 years participated in the current study. The examined vessels included brachial, radial, ulnar, popliteal, anterior and posterior tibial arteries. The experimental parameters were recorded with the use of Duplex ultrasound at rest. Diastolic diameter and blood mean flow velocity of the examined arteries in Judo athletes were found to be both significantly increased (p < 0.05 compared to the findings of the control groups. In male Judo athletes the brachial (p < 0.001, radial (p < 0.001, and anterior tibial artery (p < 0.001 presented the highest difference on the diastolic diameter, compared with the control male group. In female Judo athletes, ulnar (p < 0.001, radial (p < 0.001, and brachial (p < 0.001 arteries illustrated the highest diastolic diameter. The highest blood mean flow velocity was recorded in ulnar (p < 0.001 and popliteal arteries (p < 0.001 of the Judo athletes groups. Recording differences between the two genders, male participants presented larger arteries than females. Conclusively, Judo has been found to be a highly demanding physical sport, involving upper and lower limbs leading to significant arterial adaptations. Obtaining vascular parameters provide a useful tool to the medical team, not only in the direction of enhancement of the efficacy of physical training, but in unknown so far parameters that may influence athletic performance of both male and female elite Judokas

  7. Forearm interosseous membrane imaging and anatomy

    Energy Technology Data Exchange (ETDEWEB)

    McGinley, Joseph C. [Temple University, School of Medicine, Philadelphia, Pennsylvania (United States); Roach, Neil [Hospital of the University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania (United States); Gaughan, John P. [Temple University, Department of Biostatistics, Philadelphia, Pennsylvania (United States); Kozin, Scott H. [Shriners Hospitals for Children, Pediatric Hand and Upper Extremity Surgery, Philadelphia (United States); Temple University, Department of Orthopaedic Surgery, Philadelphia, Pennsylvania (United States)

    2004-10-01

    To determine the regional thickness variation of the interosseous membrane (IOM) along the forearm and validate magnetic resonance imaging of the IOM with laser micrometry. Axial thickness measurements of 12 cadaver forearms were obtained using magnetic resonance imaging (MRI) at radial, central, and ulnar locations. The specimens were dissected, and IOM thickness measured using a laser micrometer. MRI and laser measurements of the main and oblique IOM bundles were compared. An axial thickness profile was plotted versus forearm length, and radial, central, and ulnar positions were compared. The main bundle thickness was 2.18{+-}0.20 mm using laser micrometry, which was not significantly different from MRI measurements (1.86{+-}0.25 mm, p=0.11, power = 0.84). The dorsal oblique bundle thickness was not significantly different between measurement methods (2.93{+-}0.77 mm and 3.30{+-}1.64 mm using laser micrometry and MRI respectively, p=0.75, power = 0.04). Both methods demonstrated a progressive increase in thickness proximally within the forearm. MRI measurements demonstrated a significantly greater thickness increase in the radial location compared to the central location (slope = 2.26 and 1.05, r{sup 2}=0.31 and 0.12 respectively, p<0.05). The ulnar slope was not significantly different from zero (r{sup 2}=0.02, p>0.05). Our findings describe the varying IOM anatomy using MRI, and determined the location of the clinically important IOM fiber bundles. This study confirms the accuracy of MR imaging of the IOM by comparison with a laser micrometer, and demonstrates the thickness variation along the forearm. This information may be used to identify changes in IOM anatomy with both acute IOM injury and chronic fiber attenuation. (orig.)

  8. Angular distribution of oriented nucleus fission neutrons

    International Nuclear Information System (INIS)

    Barabanov, A.L.; Grechukhin, D.P.

    1982-01-01

    Calculations of anisotropy of angular distribution of oriented 235 U nuclei thermal fission neutrons have been carried out. the neutrons were assumed to evaporate isotropically by completely accelerated fragements in the fragment system with only its small part, i. e. fission-producing neutrons, emitted at the moment of neck break. It has been found out that at low energies of neutrons Esub(n)=1-2 MeV the sensitivity of the angular distribution anisotropy to variations of spectrum of neutron evaporation from fragments and the magnitude of a share of fission-producing neutrons reaches approximately 100%, which at high energies, Esub(n) > 5 MeV it does not exceed approximately 20%. Therefore the angular distribution of fast neutrons to a greater degree of confidence may be used for restoring the angular distribution anisotropy of fragments while the angular distribution of low energy neutrons may be used for deriving information on the fission process, but only in case 6f the experiment accuracy is better than approximately 3%

  9. WIND-DRIVEN ACCRETION IN PROTOPLANETARY DISKS. II. RADIAL DEPENDENCE AND GLOBAL PICTURE

    Energy Technology Data Exchange (ETDEWEB)

    Bai Xuening, E-mail: xbai@cfa.harvard.edu [Institute for Theory and Computation, Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, MS-51, Cambridge, MA 02138 (United States)

    2013-08-01

    Non-ideal magnetohydrodynamical effects play a crucial role in determining the mechanism and efficiency of angular momentum transport as well as the level of turbulence in protoplanetary disks (PPDs), which are the key to understanding PPD evolution and planet formation. It was shown in our previous work that at 1 AU, the magnetorotational instability (MRI) is completely suppressed when both ohmic resistivity and ambipolar diffusion (AD) are taken into account, resulting in a laminar flow with accretion driven by magnetocentrifugal wind. In this work, we study the radial dependence of the laminar wind solution using local shearing-box simulations. The scaling relation on the angular momentum transport for the laminar wind is obtained, and we find that the wind-driven accretion rate can be approximated as M-dot approx. 0.91 x 10{sup -8}R{sub AU}{sup 1.21}(B{sub p}/10 mG){sup 0.93} M{sub Sun} yr{sup -1}, where B{sub p} is the strength of the large-scale poloidal magnetic field threading the disk. The result is independent of disk surface density. Four criteria are outlined for the existence of the laminar wind solution: (1) ohmic resistivity dominated the midplane region, (2) the AD-dominated disk upper layer, (3) the presence of a (not too weak) net vertical magnetic flux, and (4) sufficiently well-ionized gas beyond the disk surface. All these criteria are likely to be met in the inner region of the disk from {approx}0.3 AU to about 5-10 AU for typical PPD accretion rates. Beyond this radius, the angular momentum transport is likely to proceed due to a combination of the MRI and disk wind, and eventually completely dominated by the MRI (in the presence of strong AD) in the outer disk. Our simulation results provide key ingredients for a new paradigm on the accretion processes in PPDs.

  10. Chronologic and Geographic Trends of Triangular Fibrocartilage Complex Repair.

    Science.gov (United States)

    Saito, Taichi; Sterbenz, Jennifer M; Chung, Kevin C

    2017-11-01

    This article shows trends in triangular fibrocartilage complex (TFCC) repair since 1990 by geographic area and year. The repair methods presented in the literature were inside-out, outside-in, all-inside, and open repair. The outside-in technique was reported most often for ulnar-side tears, whereas the inside-out technique was reported most frequently for radial-side tears. Recently, a foveal reattachment technique for ulnar-side tears has garnered attention and has been reported with increasing frequency, especially in Asia, because the deepest portion of TFCC, attached to fovea, plays a key role in stabilizing the distal radioulnar joint. Understanding these trends can help clinicians best treat TFCC tears. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Responsive web design with AngularJS

    CERN Document Server

    Patel, Sandeep Kumar

    2014-01-01

    If you are an AngularJS developer who wants to learn about responsive web application development, this book is ideal for you. Responsive Web Design with AngularJS is intended for web developers or designers with a basic knowledge of HTML, CSS, and JavaScript.

  12. Whole-body angular momentum during stair ascent and descent.

    Science.gov (United States)

    Silverman, Anne K; Neptune, Richard R; Sinitski, Emily H; Wilken, Jason M

    2014-04-01

    The generation of whole-body angular momentum is essential in many locomotor tasks and must be regulated in order to maintain dynamic balance. However, angular momentum has not been investigated during stair walking, which is an activity that presents a biomechanical challenge for balance-impaired populations. We investigated three-dimensional whole-body angular momentum during stair ascent and descent and compared it to level walking. Three-dimensional body-segment kinematic and ground reaction force (GRF) data were collected from 30 healthy subjects. Angular momentum was calculated using a 13-segment whole-body model. GRFs, external moment arms and net joint moments were used to interpret the angular momentum results. The range of frontal plane angular momentum was greater for stair ascent relative to level walking. In the transverse and sagittal planes, the range of angular momentum was smaller in stair ascent and descent relative to level walking. Significant differences were also found in the ground reaction forces, external moment arms and net joint moments. The sagittal plane angular momentum results suggest that individuals alter angular momentum to effectively counteract potential trips during stair ascent, and reduce the range of angular momentum to avoid falling forward during stair descent. Further, significant differences in joint moments suggest potential neuromuscular mechanisms that account for the differences in angular momentum between walking conditions. These results provide a baseline for comparison to impaired populations that have difficulty maintaining dynamic balance, particularly during stair ascent and descent. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. In vivo metacarpophalanageal joint collateral ligament length changes during flexion.

    Science.gov (United States)

    Sun, Y C; Sheng, X M; Chen, J; Qian, Z W

    2017-07-01

    We investigated the in vivo length changes of the collateral ligaments of metacarpophalangeal joint during flexion. We obtained computed tomography scans of index, middle, ring and little fingers at 0°, 30°, 60° and 90° of joint flexion from six hands of six healthy adult volunteers. Three of them had their dominant right hand studied, and the other three had their non-dominant left hand studied. We measured and analysed the radial and ulnar collateral ligaments of each metacarpophalangeal joint from the reconstructed images. We found that the dorsal and middle portions of the both radial and ulnar collateral ligament lengthened progressively during digital flexion and reached the maximum at 90° flexion. The length of the volar portion increased from 0° to 30° flexion and then decreased from 30° to 60° flexion, reaching the minimum at 90°. In conclusion, three portions of collateral ligaments on both sides of the metacarpophalangeal joint have variable length changes during flexion, which act to stabilize the joint through its flexion arc.

  14. Functional anatomy and biomechanics of the carpus

    International Nuclear Information System (INIS)

    Schmitt, R.

    2006-01-01

    The wrist is an exceedingly complex structure composed of several joints and a dedicated ligamentous system. Its functional principles allow a wide range of carpal motion and make the wrist remarkably resistant to external stress forces: The proximal carpal row serves as an intercalated link interposed between the static elements of both the forearm and the distal carpal row. Like a flexible placeholder, the proximal row synchronously adapts to the spatial and temporal requirements of the wrist. There are synergistic movement patterns including simultaneous flexion of the proximal row as the wrist is deviated radially and simultaneous extension during ulnar deviation. Together with pronosupination of the radioulnar joints, the combined radial/ulnar inclination and flexion/extension enable spherical, out-of-plane movements of the hand. Carpal function is best explained by the ''model of a ring under tension.'' This review addresses the anatomy and the biomechanics of the wrist and illustrates systematic image analysis by using carpal lines and angles as well as indices of carpal height. (orig.) [de

  15. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  16. Blending of Radial HF Radar Surface Current and Model Using ETKF Scheme For The Sunda Strait

    Science.gov (United States)

    Mujiasih, Subekti; Riyadi, Mochammad; Wandono, Dr; Wayan Suardana, I.; Nyoman Gede Wiryajaya, I.; Nyoman Suarsa, I.; Hartanto, Dwi; Barth, Alexander; Beckers, Jean-Marie

    2017-04-01

    Preliminary study of data blending of surface current for Sunda Strait-Indonesia has been done using the analysis scheme of the Ensemble Transform Kalman Filter (ETKF). The method is utilized to combine radial velocity from HF Radar and u and v component of velocity from Global Copernicus - Marine environment monitoring service (CMEMS) model. The initial ensemble is based on the time variability of the CMEMS model result. Data tested are from 2 CODAR Seasonde radar sites in Sunda Strait and 2 dates such as 09 September 2013 and 08 February 2016 at 12.00 UTC. The radial HF Radar data has a hourly temporal resolution, 20-60 km of spatial range, 3 km of range resolution, 5 degree of angular resolution and spatial resolution and 11.5-14 MHz of frequency range. The u and v component of the model velocity represents a daily mean with 1/12 degree spatial resolution. The radial data from one HF radar site is analyzed and the result compared to the equivalent radial velocity from CMEMS for the second HF radar site. Error checking is calculated by root mean squared error (RMSE). Calculation of ensemble analysis and ensemble mean is using Sangoma software package. The tested R which represents observation error covariance matrix, is a diagonal matrix with diagonal elements equal 0.05, 0.5 or 1.0 m2/s2. The initial ensemble members comes from a model simulation spanning a month (September 2013 or February 2016), one year (2013) or 4 years (2013-2016). The spatial distribution of the radial current are analyzed and the RMSE values obtained from independent HF radar station are optimized. It was verified that the analysis reproduces well the structure included in the analyzed HF radar data. More importantly, the analysis was also improved relative to the second independent HF radar site. RMSE of the improved analysis is better than first HF Radar site Analysis. The best result of the blending exercise was obtained for observation error variance equal to 0.05 m2/s2. This study is

  17. ANGULAR MOMENTUM ACQUISITION IN GALAXY HALOS

    International Nuclear Information System (INIS)

    Stewart, Kyle R.; Brooks, Alyson M.; Bullock, James S.; Maller, Ariyeh H.; Diemand, Jürg; Wadsley, James; Moustakas, Leonidas A.

    2013-01-01

    We use high-resolution cosmological hydrodynamic simulations to study the angular momentum acquisition of gaseous halos around Milky-Way-sized galaxies. We find that cold mode accreted gas enters a galaxy halo with ∼70% more specific angular momentum than dark matter averaged over cosmic time (though with a very large dispersion). In fact, we find that all matter has a higher spin parameter when measured at accretion than when averaged over the entire halo lifetime, and is well characterized by λ ∼ 0.1, at accretion. Combined with the fact that cold flow gas spends a relatively short time (1-2 dynamical times) in the halo before sinking to the center, this naturally explains why cold flow halo gas has a specific angular momentum much higher than that of the halo and often forms ''cold flow disks.'' We demonstrate that the higher angular momentum of cold flow gas is related to the fact that it tends to be accreted along filaments.

  18. Variations in the usage and composition of a radial cocktail during radial access coronary angiography procedures.

    LENUS (Irish Health Repository)

    Pate, G

    2011-10-01

    A survey was conducted of medication administered during radial artery cannulation for coronary angiography in 2009 in Ireland; responses were obtained for 15 of 20 centres, in 5 of which no radial access procedures were undertaken. All 10 (100%) centres which provided data used heparin and one or more anti-spasmodics; verapamil in 9 (90%), nitrate in 1 (10%), both in 2 (20%). There were significant variations in the doses used. Further work needs to be done to determine the optimum cocktail to prevent radial artery injury following coronary angiography.

  19. Orbital angular momentum exchange in post-collision interaction

    International Nuclear Information System (INIS)

    van der Burgt, P.J.M.; van Eck, J.; Heideman, H.G.M.

    1985-01-01

    The authors study the exchange of orbital angular mementum between the scattered and the ejected electron. The angular distribution of electrons ejected by the He (2s 2 ) 2 S autoionizing state after its excitation via the He (2s2p 2 ) 2 D resonance is measured. Taking into accout interference with electrons from the direct ionization of helium, the authors are able to show that the measured anisotropic angular distribution is the result of an orbital angular momentum exchange during the post-collision interaction

  20. Design of radial reinforcement for prestressed concrete containments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shen, E-mail: swang@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States); Munshi, Javeed A., E-mail: jamunshi@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States)

    2013-02-15

    Highlights: ► A rigorous formulae is proposed to calculate radial stress within prestressed concrete containments. ► The proposed method is validated by finite element analysis in an illustrative practical example. ► A partially prestressed condition is more critical than a fully prestressed condition for radial tension. ► Practical design consideration is provided for detailing of radial reinforcement. -- Abstract: Nuclear containments are critical components for safety of nuclear power plants. Failure can result in catastrophic safety consequences as a result of leakage of radiation. Prestressed concrete containments have been used in large nuclear power plants with significant design internal pressure. These containments are generally reinforced with prestressing tendons in the circumferential (hoop) and meridional (vertical) directions. The curvature effect of the tendons introduces radial tensile stresses in the concrete shell which are generally neglected in the design of such structures. It is assumed that such tensile radial stresses are small as such no radial reinforcement is provided for this purpose. But recent instances of significant delaminations in Crystal River Unit 3 in Florida have elevated the need for reevaluation of the radial tension issue in prestressed containment. Note that currently there are no well accepted industry standards for design and detailing of radial reinforcement. This paper discusses the issue of radial tension in prestressed cylindrical and dome shaped structures and proposes formulae to calculate radial stresses. A practical example is presented to illustrate the use of the proposed method which is then verified by using state of art finite element analysis. This paper also provides some practical design consideration for detailing of radial reinforcement in prestressed containments.

  1. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  2. Angular Momentum

    Science.gov (United States)

    Shakur, Asif; Sinatra, Taylor

    2013-01-01

    The gyroscope in a smartphone was employed in a physics laboratory setting to verify the conservation of angular momentum and the nonconservation of rotational kinetic energy. As is well-known, smartphones are ubiquitous on college campuses. These devices have a panoply of built-in sensors. This creates a unique opportunity for a new paradigm in…

  3. Tidal Forces in Dyonic Reissner-Nördstrom Black Hole

    Science.gov (United States)

    Sharif, M.; Kousar, Lubna

    2018-03-01

    This paper investigates the tidal as well as magnetic charge effects produced in dyonic Reissner-Nordström black hole. We evaluate Newtonian radial acceleration using radial geodesics for freely falling test particles. We establish system of equations governing radial and angular tidal forces using geodesic deviation equation and discuss their solutions for bodies falling freely towards this black hole. The radial tidal force turns out to be compressing outside the event horizon whereas the angular tidal force changes sign between event and Cauchy horizons unlike Schwarzschild black hole. The radial geodesic component starts decreasing in dyonic Reissner-Nordström black hole unlike Schwarzschild case. We conclude that magnetic charge strongly affects the radial as well as angular components of tidal force.

  4. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  5. Atraumatic Main-En-Griffe due to Ulnar Nerve Leprosy

    International Nuclear Information System (INIS)

    Aswani, Yashant; Saifi, Shenaz

    2016-01-01

    Leprosy is the most common form of treatable peripheral neuropathy. However, in spite of effective chemotherapeutic agents, neuropathy and associated deformities are seldom ameliorated to a significant extent. This necessitates early diagnosis and treatment. Clinical examination of peripheral nerves is highly subjective and inaccurate. Electrophysiological studies are painful and expensive. Ultrasonography circumvents these demerits and has emerged as the preferred modality for probing peripheral nerves. We describe a 23-year-old male who presented with weakness and clawing of the medial digits of the right hand (main-en-griffe) and a few skin lesions since eighteen months. The right ulnar nerve was thickened and exquisitely tender on palpation. Ultrasonography revealed an extensive enlargement of the nerve with presence of intraneural color Doppler signals suggestive of acute neuritis. Skin biopsy was consistent with borderline tuberculoid leprosy with type 1 lepra reaction. The patient was started on WHO multidrug therapy for paucibacillary leprosy along with antiinflammatory drugs. Persistence of vascular signals at two months’ follow-up has led to continuation of the steroid therapy. The patient is compliant with the treatment and is on monthly follow-up. In this manuscript, we review multitudinous roles of ultrasonography in examination of peripheral nerves in leprosy. Ultrasonography besides diagnosing enlargement of nerves in leprosy and acute neuritis due to lepra reactions, guides the duration of anti-inflammatory therapy in lepra reactions. Further, it is relatively inexpensive, non-invasive and easily available. All these features make ultrasonography a preferred modality for examination of peripheral nerves

  6. Angular distributions in quasi-fission reactions

    International Nuclear Information System (INIS)

    Luetzenkirchen, K.; Kratz, J.V.; Lucas, R.; Poitou, J.; Gregoire, C.; Wirth, G.; Bruechle, W.; Suemmerer, K.

    1985-10-01

    Angular distributions for fission-like fragments were measured in the systems 50 Ti, 56 Fe + 208 Pb by applying an off-line KX-ray activation technique. The distributions d 2 sigma/dTHETAdZ exhibit forward-backward asymmetries that are strongly Z-dependent. They result from a process (quasi-fission) which yields nearly symmetric masses in times comparable to the rotational period of the composite system. A method for obtaining the variance of the tilting angular momentum, K 0 2 , from these skewed, differential angular distributions is described. The results indicate that the tilting mode is not fully excited in quasi-fission reactions. The results are compared to the sum of the variances of all statistical spin components, measured via γ-multiplicities. Integration of the angular distributions d 2 sigma/dTHETAdZ over all values of Z yields integral angular distributions dsigma/dTHETA and dsigma/dΩ symmetric around 90 0 . The associated unusually large anisotropies do not at all provide an adequate basis for tests or modifications of the transition state theory. A deconvolution of d 2 sigma/dTHETAdZ is performed with gaussian distributions depending on rotational angles ΔTHETA extending over a range of up to 540 0 . From the mean values a time scale for the evolution of K 0 is calculated. (orig.)

  7. Photon beam polarization and non-dipolar angular distributions

    International Nuclear Information System (INIS)

    Peshkin, M.

    1996-01-01

    Angular distributions of ejecta from unoriented atoms and molecules depend upon the polarization state of the incident x-rays as well as upon the dynamics of the physical systems being studied. I recommend a simple geometrical way of looking at the polarization and its effects upon angular distributions. The polarization is represented as a vector in a parameter space that faithfully represents the polarization of the beam. The simple dependence of the angular dependence of the angular distributions on the polarization vector enables easy extraction of the dynamical information contained in those angular distributions. No new physical results emerge from this geometrical approach, but known consequences of the symmetries appear in an easily visualized form that I find pleasing and that has proved to be useful for planning experiments and for analyzing data

  8. Beam Angular Divergence Effects in Ion Implantation

    International Nuclear Information System (INIS)

    Horsky, T. N.; Hahto, S. K.; Bilbrough, D. G.; Jacobson, D. C.; Krull, W. A.; Goldberg, R. D.; Current, M. I.; Hamamoto, N.; Umisedo, S.

    2008-01-01

    An important difference between monomer ion beams and heavy molecular beams is a significant reduction in beam angular divergence and increased on-wafer angular accuracy for molecular beams. This advantage in beam quality stems from a reduction in space-charge effects within the beam. Such improved angular accuracy has been shown to have a significant impact on the quality and yield of transistor devices [1,12]. In this study, B 18 H x + beam current and angular divergence data collected on a hybrid scanned beam line that magnetically scans the beam across the wafer is presented. Angular divergence is kept below 0.5 deg from an effective boron energy of 200 eV to 3000 eV. Under these conditions, the beam current is shown analytically to be limited by space charge below about 1 keV, but by the matching of the beam emittance to the acceptance of the beam line above 1 keV. In addition, results of a beam transport model which includes variable space charge compensation are presented, in which a drift mode B 18 H x + beam is compared to an otherwise identical boron beam after deceleration. Deceleration is shown to introduce significant space-charge blow up resulting in a large on-wafer angular divergence. The divergence effects introduced by wafer charging are also discussed.

  9. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    International Nuclear Information System (INIS)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B.; Brooks, Jeffrey J.

    2018-01-01

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  10. Not all sagittal band tears come with extensor instability. A case report with radiological and operative correlation

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuo; Jacob, Jubin; Ghasemiesfe, Ahmadreza; Marrinan, Greg B. [Yale New Haven Health Bridgeport Hospital, Bridgeport, CT (United States); Brooks, Jeffrey J. [Orthopedic Surgery and Sports Medicine Center, New Canaan, CT (United States)

    2018-04-15

    The sagittal bands are a component of the extensor hood. They serve an important role in stabilizing the extensor tendon by forming a ''check-rein'' to radial-ulnar translation of the tendon over the metacarpal head, and extending the metacarpophalangeal (MCP) joint by virtue of attaching the extensor tendon to the palmar plate. Injury to the sagittal band is thought to cause extensor instability and subluxation to the contralateral side by disruption of this ''check-rein'' function, although recent evidence from cadaver studies suggests that ulnar sagittal band tear may be spared of extensor instability. As a case in point, we encountered a patient with surgically proven ulnar sagittal band tear, who did not have any extensor tendon subluxation or any limitation in motion. Intraoperative findings demonstrated a chronic-appearing ulnar sagittal band tear, indicating that chronic injury with fibrosis may stabilize the central band. Therefore, in patients with metacarpophalangeal pain without central tendon subluxation or limitation of motion, it remains important to raise the concern of sagittal band tear for appropriate treatment. We present the clinical course of this case, with radiological and operative findings, followed by a review of the relevant literature. (orig.)

  11. Internal bone transport using a cannulated screw as a mounting device in the treatment of a post-infective ulnar defect.

    Science.gov (United States)

    Tsitskaris, Konstantinos; Havard, Heledd; Bijlsma, Paulien; Hill, Robert A

    2016-04-01

    Bone transport techniques can be used to address the segmental bone loss occurring after debridement for infection. Secure fixation of the bone transport construct to the bone transport segment can be challenging, particularly if the bone is small and osteopenic. We report a case of a segmental ulnar bone defect in a young child treated with internal bone transport using a cannulated screw as the mounting device. We found this technique particularly useful in the treatment of bone loss secondary to infection, where previous treatment and prolonged immobilisation had led to osteopenia. This technique has not been previously reported.

  12. Ghost Imaging Using Orbital Angular Momentum

    Institute of Scientific and Technical Information of China (English)

    赵生妹; 丁建; 董小亮; 郑宝玉

    2011-01-01

    We present a novel encoding scheme in a ghost-imaging system using orbital angular momentum. In the signal arm, object spatial information is encoded as a phase matrix. For an N-grey-scale object, different phase matrices, varying from 0 to K with increment n/N, are used for different greyscales, and then they are modulated to a signal beam by a spatial light modulator. According to the conservation of the orbital angular momentum in the ghost imaging system, these changes will give different coincidence rates in measurement, and hence the object information can be extracted in the idler arm. By simulations and experiments, the results show that our scheme can improve the resolution of the image effectively. Compared with another encoding method using orbital angular momentum, our scheme has a better performance for both characters and the image object.%We present a novel encoding scheme in a ghost-imaging system using orbital angular momentum.In the signal arm,object spatial information is encoded as a phase matrix.For an N-grey-scale object,different phase matrices,varying from 0 to π with increment π/N,are used for different greyscales,and then they are modulated to a signal beam by a spatial light modulator.According to the conservation of the orbital angular momentum in the ghost imaging system,these changes will give different coincidence rates in measurement,and hence the object information can be extracted in the idler arm.By simulations and experiments,the results show that our scheme can improve the resolution of the image effectively.Compared with another encoding method using orbital angular momentum,our scheme has a better performance for both characters and the image object.

  13. Angular momentum in general relativity

    International Nuclear Information System (INIS)

    Prior, C.R.

    1977-01-01

    The definition of angular momentum proposed in part I of this series (Prior. Proc. R. Soc. Lond.; A354:379 (1977)) is investigated when applied to rotating black holes. It is shown how to use the formula to evaluate the angular momentum of a stationary black hole. This acts as a description of a background space on which the effect of first matter and then gravitational perturbations is considered. The latter are of most interest and the rate of change of angular momentum, dJ/dt, is found as an expression in the shear induced in the event horizon by the perturbation and in its time integral. Teukolsky's solutions (Astrophys. J.; 185:635 (1973)) for the perturbed component of the Weyl tensor are then used to find this shear and hence to give an exact answer for dJ/dt. One of the implications of the result is a direct verification of Bekenstein's formula (Phys. Rev.; 7D:949 (1973)) relating in a simple way the rate of change of angular momentum to the rate of change of mass caused by a plane wave. A more general expression is also given for dM/dt. Considering only stationary perturbations, it is shown how to generalize the definition of angular momentum so as to include information about its direction as well. Three problems are particularly discussed - a single moon, two or more moons and a ring of matter causing the perturbation - since they provide illustrations of all the main features of the black hole's behaviour. In every case it is found that the black hole realigns its axis of rotation so that the final configuration is axisymmetric if possible; otherwise is slows down completely to reach a static state. (author)

  14. Jet angularity measurements for single inclusive jet production

    Science.gov (United States)

    Kang, Zhong-Bo; Lee, Kyle; Ringer, Felix

    2018-04-01

    We study jet angularity measurements for single-inclusive jet production at the LHC. Jet angularities depend on a continuous parameter a allowing for a smooth interpolation between different traditional jet shape observables. We establish a factorization theorem within Soft Collinear Effective Theory (SCET) where we consistently take into account in- and out-of-jet radiation by making use of semi-inclusive jet functions. For comparison, we elaborate on the differences to jet angularities measured on an exclusive jet sample. All the necessary ingredients for the resummation at next-to-leading logarithmic (NLL) accuracy are presented within the effective field theory framework. We expect semiinclusive jet angularity measurements to be feasible at the LHC and we present theoretical predictions for the relevant kinematic range. In addition, we investigate the potential impact of jet angularities for quark-gluon discrimination.

  15. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  16. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  17. El colgajo fasciocutáneo dorsal ulnar en quemaduras eléctricas de la mano: un colgajo constante, rápido y seguro

    Directory of Open Access Journals (Sweden)

    Trinidad Delgado-Ruiz

    2016-03-01

    Full Text Available Antecedentes y Objetivos. La extremidad superior es el área más frecuentemente afectada en las quemaduras eléctricas de alto voltaje, con una alta tasa de amputaciones, síndromes compartimentales y defectos de partes blandas que precisan cobertura. La literatura en cuanto a la cirugía reconstructiva de la mano con quemaduras eléctricas es escasa, pero es fundamental en la fase aguda establecer un plan quirúrgico y una cobertura estable de estos frecuentes defectos en mano y muñeca. Pacientes y Método. Empleamos el colgajo fasciocutáneo dorsal ulnar en 3 pacientes con defectos cutáneos en muñeca secundarios a quemaduras eléctricas de alto voltaje, durante la fase aguda de estas lesiones. Resultados. Obtuvimos en todos los casos una cobertura estable y de alta calidad y sin registrar complicaciones relacionadas con el colgajo o con la zona donante. Conclusiones. Debido a la constancia de su pedículo, la rapidez y seguridad de su disección y la preservación de ambos ejes arteriales, el colgajo fasciocutáneo dorsal ulnar es una herramienta de primer uso en la cobertura de los defectos de la mano y de la muñeca tras quemaduras eléctricas de alto voltaje.

  18. Neurophysiological localisation of ulnar neuropathy at the elbow: Validation of diagnostic criteria developed by a taskforce of the Danish Society of clinical neurophysiology.

    Science.gov (United States)

    Pugdahl, K; Beniczky, S; Wanscher, B; Johnsen, B; Qerama, E; Ballegaard, M; Benedek, K; Juhl, A; Ööpik, M; Selmar, P; Sønderborg, J; Terney, D; Fuglsang-Frederiksen, A

    2017-11-01

    This study validates consensus criteria for localisation of ulnar neuropathy at elbow (UNE) developed by a taskforce of the Danish Society of Clinical Neurophysiology and compares them to the existing criteria from the American Association of Neuromuscular and Electrodiagnostic Medicine (AANEM). The Danish criteria are based on combinations of conduction slowing in the segments of the elbow and forearm expressed in Z-scores, and difference between the segments in m/s. Examining fibres to several muscles and sensory fibres can increase the certainty of the localisation. Diagnostic accuracy for UNE was evaluated on 181 neurophysiological studies of the ulnar nerve from 171 peer-reviewed patients from a mixed patient-group. The diagnostic reference standard was the consensus diagnosis based on all available clinical, laboratory, and electrodiagnostic information reached by a group of experienced Danish neurophysiologists. The Danish criteria had high specificity (98.4%) and positive predictive value (PPV) (95.2%) and fair sensitivity (76.9%). Compared to the AANEM criteria, the Danish criteria had higher specificity (p<0.001) and lower sensitivity (p=0.02). The Danish consensus criteria for UNE are very specific and have high PPV. The Danish criteria for UNE are reliable and well suited for use in different centres as they are based on Z-scores. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  19. Nonreconstruction Options for Treating Medial Ulnar Collateral Ligament Injuries of the Elbow in Overhead Athletes.

    Science.gov (United States)

    Clark, Nicholas J; Desai, Vishal S; Dines, Joshua D; Morrey, Mark E; Camp, Christopher L

    2018-03-01

    This review aims to describe the nonreconstructive options for treating ulnar collateral ligament (UCL) injuries ranging from nonoperative measures, including physical therapy and biologic injections, to ligament repair with and without augmentation. Nonoperative options for UCL injuries include guided physical therapy and biologic augmentation with platelet-rich plasma (PRP). In some patients, repair of the UCL has shown promising return to sport rates by using modern suture and suture anchor techniques. Proximal avulsion injuries have shown the best results after repair. Currently, there is growing interest in augmentation of UCL repair with an internal brace. The treatment of UCL injuries involves complex decision making. UCL reconstruction remains the gold standard for attritional injuries and complete tears, which occur commonly in professional athletes. However, nonreconstructive options have shown promising results for simple avulsion or partial thickness UCL injuries. Future research comparing reconstructive versus nonreconstructive options is necessary.

  20. Radial velocities of RR Lyrae stars

    International Nuclear Information System (INIS)

    Hawley, S.L.; Barnes, T.G. III

    1985-01-01

    283 spectra of 57 RR Lyrae stars have been obtained using the 2.1-m telescope at McDonald Observatory. Radial velocities were determined using a software cross-correlation technique. New mean radial velocities were determined for 46 of the stars. 11 references

  1. Transverse angular momentum in topological photonic crystals

    Science.gov (United States)

    Deng, Wei-Min; Chen, Xiao-Dong; Zhao, Fu-Li; Dong, Jian-Wen

    2018-01-01

    Engineering local angular momentum of structured light fields in real space enables applications in many fields, in particular, the realization of unidirectional robust transport in topological photonic crystals with a non-trivial Berry vortex in momentum space. Here, we show transverse angular momentum modes in silicon topological photonic crystals when considering transverse electric polarization. Excited by a chiral external source with either transverse spin angular momentum or transverse phase vortex, robust light flow propagating along opposite directions is observed in several kinds of sharp-turn interfaces between two topologically-distinct silicon photonic crystals. A transverse orbital angular momentum mode with alternating phase vortex exists at the boundary of two such photonic crystals. In addition, unidirectional transport is robust to the working frequency even when the ring size or location of the pseudo-spin source varies in a certain range, leading to the superiority of the broadband photonic device. These findings enable one to make use of transverse angular momentum, a kind of degree of freedom, to achieve unidirectional robust transport in the telecom region and other potential applications in integrated photonic circuits, such as on-chip robust delay lines.

  2. Staggering of angular momentum distribution in fission

    Science.gov (United States)

    Tamagno, Pierre; Litaize, Olivier

    2018-03-01

    We review here the role of angular momentum distributions in the fission process. To do so the algorithm implemented in the FIFRELIN code [?] is detailed with special emphasis on the place of fission fragment angular momenta. The usual Rayleigh distribution used for angular momentum distribution is presented and the related model derivation is recalled. Arguments are given to justify why this distribution should not hold for low excitation energy of the fission fragments. An alternative ad hoc expression taking into account low-lying collectiveness is presented as has been implemented in the FIFRELIN code. Yet on observables currently provided by the code, no dramatic impact has been found. To quantify the magnitude of the impact of the low-lying staggering in the angular momentum distribution, a textbook case is considered for the decay of the 144Ba nucleus with low excitation energy.

  3. Outcomes and Return to Sport After Ulnar Collateral Ligament Reconstruction in Adolescent Baseball Players.

    Science.gov (United States)

    Saper, Michael; Shung, Joseph; Pearce, Stephanie; Bompadre, Viviana; Andrews, James R

    2018-04-01

    The number of ulnar collateral ligament (UCL) reconstructions in adolescent athletes has increased over the past 2 decades. Clinical results in this population have not been well studied. The purpose of this study was to evaluate the outcomes and return to sport after UCL reconstruction in a large group of adolescent baseball players. We hypothesized that excellent clinical outcomes and high rates of return to sport would be observed in this population at a minimum 2-year follow-up. Case series; Level of evidence, 4. We reviewed 140 adolescent (aged ≤19 years) baseball players who underwent UCL reconstruction with the American Sports Medicine Institute (ASMI) technique by a single surgeon. Medical records were reviewed for patient demographics, injury characteristics, operative details, and surgical complications. Patient-reported outcomes were assessed using the Conway scale, the Andrews-Timmerman (A-T) score, the Kerlan-Jobe Orthopaedic Clinic (KJOC) score, and a 0- to 100-point subjective scale for elbow function and satisfaction. Return to sporting activity was assessed using a custom-designed questionnaire. The mean age at the time of surgery was 18.0 years (range, 13-19 years), and the mean follow-up was 57.9 months (range, 32.4-115.4 months). Over half (60%) of patients were high school athletes. The mean duration of symptoms before surgery was 6.9 months (range, 0.5-60.0 months). Partial tears were identified in 57.9% of patients, and 41.3% of patients had preoperative ulnar nerve symptoms. Graft type included the ipsilateral palmaris in 77.1% of patients. Concomitant procedures were performed in 25% of patients. Outcomes on the Conway scale were "excellent" in 86.4% of patients. The mean A-T and KJOC scores were 97.3 ± 6.1 and 85.2 ± 14.6, respectively. Mean patient satisfaction was 94.4. Overall, 97.8% of patients reported returning to sport at a mean of 11.6 months (range, 5-24 months), and 89.9% of patients returned to sport at the same level of

  4. Etiology and mechanisms of ulnar and median forearm nerve injuries

    Directory of Open Access Journals (Sweden)

    Puzović Vladimir

    2015-01-01

    Full Text Available Bacgraund/Aim. Most often injuries of brachial plexus and its branches disable the injured from using their arms and/or hands. The aim of this study was to investigate the etiology and mechanisms of median and ulnar forearm nerves injuries. Methods. This retrospective cohort study included 99 patients surgically treated in the Clinic of Neurosurgery, Clinical Center of Serbia, from January 1st, 2000 to December 31st, 2010. All data are obtained from the patients' histories. Results. The majority of the injured patients were male, 81 (81.8%, while only 18 (18.2% were females, both mainly with nerve injuries of the distal forearm - 75 (75.6%. Two injury mechanisms were present, transection in 85 patients and traction and contusion in 14 of the patients. The most frequent etiological factor of nerve injuries was cutting, in 61 of the patients. Nerve injuries are often associated with other injuries. In the studied patients there were 22 vascular injuries, 33 muscle and tendon injuries and 20 bone fractures. Conclusion. The majority of those patients with peripheral nerve injuries are represented in the working age population, which is a major socioeconomic problem. In our study 66 out of 99 patients were between 17 and 40 years old, in the most productive age. The fact that the majority of patients had nerve injuries of the distal forearm and that they are operated within the first 6 months after injury, promises them good functional prognosis.

  5. Radial MR images of the knee

    International Nuclear Information System (INIS)

    Hewes, R.C.; Miller, T.R.

    1988-01-01

    To profile optimally each portion of the meniscus, the authors use the multiangle, multisection feature of a General Electric SIGNA 1.5-T imager to produce radial images centered on each meniscus. A total of 12-15 sections are imaged at 10 0 -15 0 intervals of each meniscus, yielding perpendicular images of the entire meniscus, comparable with the arthrographic tangential views. The authors review their technique and demonstrate correlation cases between the radial gradient recalled acquisition in a steady state sequences, sagittal and coronal MR images, and arthrograms. Radial images should be a routine part of knee MR imaging

  6. Exposing Library Services with AngularJS

    OpenAIRE

    Jakob Voß; Moritz Horn

    2014-01-01

    This article provides an introduction to the JavaScript framework AngularJS and specific AngularJS modules for accessing library services. It shows how information such as search suggestions, additional links, and availability can be embedded in any website. The ease of reuse may encourage more libraries to expose their services via standard APIs to allow usage in different contexts.

  7. 21 CFR 866.4800 - Radial immunodiffusion plate.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4800 Radial immunodiffusion plate. (a) Identification. A radial immunodiffusion plate for clinical use...

  8. Experimental determination of high angular momentum states

    International Nuclear Information System (INIS)

    Barreto, J.L.V.

    1985-01-01

    The current knowledge of the atomic nucleus structure is summarized. A short abstract of the nuclear properties at high angular momentum and a more detailed description of the experimental methods used in the study of high angular momenta is made. (L.C.) [pt

  9. Accelerated rotation with orbital angular momentum modes

    CSIR Research Space (South Africa)

    Schulze, C

    2015-04-01

    Full Text Available . As the angular acceleration takes place in a bounded space, the azimuthal degree of freedom, such fields accelerate periodically as they propagate. Notably, the amount of angular acceleration is not limited by paraxial considerations, may be tailored for large...

  10. Staggering of angular momentum distribution in fission

    Directory of Open Access Journals (Sweden)

    Tamagno Pierre

    2018-01-01

    Full Text Available We review here the role of angular momentum distributions in the fission process. To do so the algorithm implemented in the FIFRELIN code [?] is detailed with special emphasis on the place of fission fragment angular momenta. The usual Rayleigh distribution used for angular momentum distribution is presented and the related model derivation is recalled. Arguments are given to justify why this distribution should not hold for low excitation energy of the fission fragments. An alternative ad hoc expression taking into account low-lying collectiveness is presented as has been implemented in the FIFRELIN code. Yet on observables currently provided by the code, no dramatic impact has been found. To quantify the magnitude of the impact of the low-lying staggering in the angular momentum distribution, a textbook case is considered for the decay of the 144Ba nucleus with low excitation energy.

  11. Stirling Engine With Radial Flow Heat Exchangers

    Science.gov (United States)

    Vitale, N.; Yarr, George

    1993-01-01

    Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

  12. Equine ulnar fracture repair with locking compression plates can be associated with inadvertent penetration of the lateral cortex of the radius.

    Science.gov (United States)

    Kuemmerle, Jan M; Kühn, Karolin; Bryner, Marco; Fürst, Anton E

    2013-10-01

    To evaluate if the use of locking head screws (LHS) in the distal holes of a locking compression plate (LCP) applied to the caudal aspect of the ulna to treat equine ulnar fractures is associated with a risk of injury to the lateral cortex of the radius. Controlled laboratory study. Cadaveric equine forelimbs (n = 8 pair). After transverse ulnar osteotomy, osteosynthesis was performed with a narrow 10-13 hole 4.5/5.0 LCP applied to the caudal aspect of each ulna. The distal 3 holes were filled with 4.5 mm cortex screws (CS) in 1 limb (group 1) and with 5.0 mm LHS contralaterally (group 2). CS were inserted in an angle deemed appropriate by the surgeon and LHS were inserted perpendicular to the plate. Implant position and injury to the lateral cortex of the radius were assessed by radiography, CT, and limb dissection. In group 1, injury of the lateral radius cortex did not occur. In group 2, 4 limbs and 6/24 LHS were associated with injury of the lateral radius cortex by penetration of a LHS. This difference was statistically significant. CS were inserted with a mean angle of 17.6° from the sagittal plane in a caudolateral-craniomedial direction. Use of LHS in the distal part of a LCP applied to the caudal aspect of the ulna is associated with a risk of inadvertent injury to the lateral cortex of the radius. © Copyright 2013 by The American College of Veterinary Surgeons.

  13. Arthroscopic assisted tendon reconstruction for triangular fibrocartilage complex irreparable tears.

    Science.gov (United States)

    Luchetti, R; Atzei, A

    2017-05-01

    We report our 11-year experience of performing arthroscopically assisted triangular fibrocartilage complex reconstruction in the treatment of chronic distal radio-ulnar joint instability resulting from irreparable triangular fibrocartilage complex injuries. Eleven patients were treated. Three skin incisions were made in order to create radial and ulna tunnels for passage of the tendon graft, which is used to reconstruct the dorsal and palmar radio-ulnar ligaments, under fluoroscopic and arthroscopic guidance. At a mean follow-up of 68 months all but one had a stable distal radio-ulnar joint. Pain and grip strength, Mayo wrist score, Disability of the Arm Hand and Shoulder and patient-rated wrist and hand evaluation scores improved. The ranges of forearm rotation remained largely unchanged. Complications included an early tendon graft tear, two late-onset graft ruptures, one ulna styloid fracture during surgery and persistent wrist discomfort during forearm rotation requiring tendon graft revision in one case. An arthroscopic assisted approach for triangular fibrocartilage complex reconstruction appears safe and produces comparable results with the open technique. IV.

  14. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  15. Angular distributions of sputtered particles from NiTi alloy

    International Nuclear Information System (INIS)

    Neshev, I.; Hamishkeev, V.; Chernysh, V.S.; Postnikov, S.; Mamaev, B.

    1993-01-01

    The angular distributions of sputtered Ni and Ti from a polycrystalline NiTi (50-50%) alloy are investigated by Auger electron spectroscopy and Rutherford backscattering spectroscopy. A difference in the angular distributions is observed with Ni being sputtered preferentially near the surface normal. A computer program for the calculation of the angular distributions of constituents sputtered from binary targets is created and used. The mechanisms responsible for the observed differences in the angular distributions are discussed. It is found that the collisional cascade theory is not directly applicable to the results of the constituents' angular distributions obtained in the presence of oxygen. The fitted coefficients of bombardment-induced segregation are found to be greater than the experimentally obtained ones. (author)

  16. Radial Artery as a Coronary Artery Bypass Conduit: 20-Year Results.

    Science.gov (United States)

    Gaudino, Mario; Tondi, Paolo; Benedetto, Umberto; Milazzo, Valentina; Flore, Roberto; Glieca, Franco; Ponziani, Francesca Romana; Luciani, Nicola; Girardi, Leonard N; Crea, Filippo; Massetti, Massimo

    2016-08-09

    There is a lack of evidence for the choice of the second conduit in coronary surgery. The radial artery (RA) is a possible option, but few data on very-long-term outcomes exist. This study describes 20-year results of RA grafts used for coronary artery bypass grafting and the effects of RA removal on forearm circulation. We report the results of the prospective 20-year follow-up of the first 100 consecutive patients who received the RA as a coronary bypass conduit at our institution. Follow-up was 100% complete. There were 64 deaths, 23 (35.9%) from cardiovascular causes. Kaplan-Meier 20-year survival was 31%. Of the 36 survivors, 33 (91.6%) underwent RA graft control at a mean of 19.0 ± 2.5 years after surgery. The RA was found to be patent in 24 cases (84.8% patency). In the overall population, probability of graft failure at 20 years was 19.0 ± 0.2% for the left internal thoracic artery (ITA), 25.0 ± 0.2% for the RA, and 55.0 ± 0.2% for the saphenous vein (p = 0.002 for RA vs. saphenous vein, 0.11 for RA vs. ITA, and p 90%, but not location of distal anastomosis, significantly influenced long-term RA graft patency. No patients reported hand or forearm symptoms. The ulnar artery diameter was increased in the operated arm (2.44 ± 0.43 mm vs. 2.01 ± 0.47 mm; p 90% stenosis. RA harvesting does not lead to hand or forearm symptoms, even at a very-long-term follow-up. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  17. Radial pattern of nuclear decay processes

    International Nuclear Information System (INIS)

    Iskra, W.; Mueller, M.; Rotter, I.; Technische Univ. Dresden

    1994-05-01

    At high level density of nuclear states, a separation of different time scales is observed (trapping effect). We calculate the radial profile of partial widths in the framework of the continuum shell model for some 1 - resonances with 2p-2h nuclear structure in 16 O as a function of the coupling strength to the continuum. A correlation between the lifetime of a nuclear state and the radial profile of the corresponding decay process is observed. We conclude from our numerical results that the trapping effect creates structures in space and time characterized by a small radial extension and a short lifetime. (orig.)

  18. Angular distributions in pre-equilibrium reactions

    International Nuclear Information System (INIS)

    Chatterjee, A.; Gupta, S.K.; Bhabha Atomic Research Centre, Bombay

    1982-10-01

    A new model is proposed for calculating angular distributions in preequilibrium reactions. In this model, as in the model of Feshbach et al. the system consisting of target plus projectile initially branches into two sets of states with either no particle in the continuum (multistep compound states) or with at least one particle in the continuum (multistep direct states). The two chains of states are treated independently by solving two sets of master equations. The multistep compound emission is assumed to be isotropic while the angular distribution of the multistep direct emission is described using the fast particle model of Mantzouranis et al. The angular distributions for 14.6 MeV neutrons calculated using this model are found to be in better agreement with the data than the fast particle model. (author)

  19. Smoothed dissipative particle dynamics with angular momentum conservation

    Energy Technology Data Exchange (ETDEWEB)

    Müller, Kathrin, E-mail: k.mueller@fz-juelich.de; Fedosov, Dmitry A., E-mail: d.fedosov@fz-juelich.de; Gompper, Gerhard, E-mail: g.gompper@fz-juelich.de

    2015-01-15

    Smoothed dissipative particle dynamics (SDPD) combines two popular mesoscopic techniques, the smoothed particle hydrodynamics and dissipative particle dynamics (DPD) methods, and can be considered as an improved dissipative particle dynamics approach. Despite several advantages of the SDPD method over the conventional DPD model, the original formulation of SDPD by Español and Revenga (2003) [9], lacks angular momentum conservation, leading to unphysical results for problems where the conservation of angular momentum is essential. To overcome this limitation, we extend the SDPD method by introducing a particle spin variable such that local and global angular momentum conservation is restored. The new SDPD formulation (SDPD+a) is directly derived from the Navier–Stokes equation for fluids with spin, while thermal fluctuations are incorporated similarly to the DPD method. We test the new SDPD method and demonstrate that it properly reproduces fluid transport coefficients. Also, SDPD with angular momentum conservation is validated using two problems: (i) the Taylor–Couette flow with two immiscible fluids and (ii) a tank-treading vesicle in shear flow with a viscosity contrast between inner and outer fluids. For both problems, the new SDPD method leads to simulation predictions in agreement with the corresponding analytical theories, while the original SDPD method fails to capture properly physical characteristics of the systems due to violation of angular momentum conservation. In conclusion, the extended SDPD method with angular momentum conservation provides a new approach to tackle fluid problems such as multiphase flows and vesicle/cell suspensions, where the conservation of angular momentum is essential.

  20. Energies and radial distributions of Bs mesons - the effect of hypercubic blocking

    Science.gov (United States)

    Koponen, Jonna

    2006-12-01

    This is a follow-up to our earlier work for the energies and the charge (vector) and matter (scalar) distributions for S-wave states in a heavy-light meson, where the heavy quark is static and the light quark has a mass about that of the strange quark. We study the radial distributions of higher angular momentum states, namely P- and D-wave states, using a "fuzzy" static quark. A new improvement is the use of hypercubic blocking in the time direction, which effectively constrains the heavy quark to move within a 2a hypercube (a is the lattice spacing). The calculation is carried out with dynamical fermions on a 163 × 32 lattice with a ≈ 0.10 fm generated using the non-perturbatively improved clover action. The configurations were gener- ated by the UKQCD Collaboration using lattice action parameters β = 5.2, c SW = 2.0171 and κ = 0.1350. In nature the closest equivalent of this heavy-light system is the Bs meson. Attempts are now being made to understand these results in terms of the Dirac equation.

  1. Intraluminal milrinone for dilation of the radial artery graft.

    Science.gov (United States)

    García-Rinaldi, R; Soltero, E R; Carballido, J; Mojica, J

    1999-01-01

    There is renewed interest in the use of the radial artery as a conduit for coronary artery bypass surgery. The radial artery is, however, a very muscular artery, prone to vasospasm. Milrinone, a potent vasodilator, has demonstrated vasodilatory properties superior to those of papaverine. In this report, we describe our technique of radial artery harvesting and the adjunctive use of intraluminal milrinone as a vasodilator in the preparation of this conduit for coronary artery bypass grafting. We have used these techniques in 25 patients who have undergone coronary artery bypass grafting using the radial artery. No hand ischemic complications have been observed in this group. Intraluminal milrinone appears to dilate and relax the radial artery, rendering this large conduit spasm free and very easy to use. We recommend the skeletonization technique for radial artery harvesting and the use of intraluminal milrinone as a radial artery vasodilator in routine myocardial revascularization. PMID:10524740

  2. Carpal pseudoerosions: a plain X-ray interpretation pitfall

    Energy Technology Data Exchange (ETDEWEB)

    Wawer, Richard [Univ. Catholique de Lille (France). Service d' Imagerie Medicale; Budzik, Jean Francois [Univ. Catholique de Lille (France). Service d' Imagerie Medicale; Univ. Nord de France, Boulogne sur Mer (France). Unite de Recherche EA 4490, Physiopathologie des Maladies Osseuses Inflammatoires; Demondion, Xavier [Univ. Lille 2 (France). Service d' Imagerie Musculosquelettique; CHRU Lille (France). Lab. d' Anatomie; Forzy, Gerard [Univ. Catholique de Lille, Lomme (France). Lab. de Biologie; Cotten, Anne [Univ. Lille 2 (France). Service d' Imagerie Musculosquelettique; Univ. Nord de France, Boulogne sur Mer (France). Unite de Recherche EA 4490, Physiopathologie des Maladies Osseuses Inflammatoires

    2014-10-15

    To examine in detail images of pseudoerosion of the wrist and hand on plain radiographs. The study was conducted with 28 cadaver wrists. During a single imaging session three techniques - plain radiography, tomosynthesis, and computed tomography - were used to visualize the wrist and hand specimens. For each technique, 20 radio-ulno-carpo-metacarpal sites known to present bone erosions in rheumatoid arthritis were analyzed by two radiologists using a standard system to score the cortical bone: normal, pseudoerosion, true erosion, or other pathology. Cohen's concordance analysis was performed to determine inter-observer and intra-observer (for the senior radiologist) agreement by site and by technique. Serial sections of two cadaver specimens were examined to determine the anatomical correlation of the pseudoerosions. On the plain radiographs, the radiologists scored many images as pseudoerosion (7.3 %), particularly in the distal ulnar portion of the capitate, the distal radial portion of the hamate, the proximal ulnar portion of the base of the third metacarpal, the proximal radial portion of the base of the fourth metacarpal, the distal ulnar portion of the hamate, and the proximal portion of the base of the fifth metacarpal. The computed tomography scan revealed that none of these doubtful images corresponded to true erosions. The anatomical correlation study showed that these images could probably be attributed to ligament insertions, thinner lamina, and enhanced cortical bone transparency. Knowledge of the anatomical carpal localizations where pseudoerosions commonly occur is a necessary prerequisite for analysis of plain radiographs performed to diagnose or monitor rheumatoid arthritis. (orig.)

  3. Resistance of the peripheral nervous system to the effects of chronic canine hypothyroidism.

    Science.gov (United States)

    Rossmeisl, J H

    2010-01-01

    Hypothyroidism has been implicated in the development of multiple peripheral mono- and polyneuropathies in dogs. The objectives of this study were to evaluate the clinical and electrophysiologic effects of experimentally induced hypothyroidism on the peripheral nervous system of dogs. Chronic hypothyroidism will induce peripheral nerve sensorimotor dysfunction. Eighteen purpose-bred, female dogs. Prospective, longitudinal study: Hypothyroidism was induced by radioactive iodine administration in 9 dogs, and the remaining 9 served as untreated controls. Neurological examinations were performed monthly. Electrophysiologic testing consisting of electromyography (EMG); motor nerve conduction studies of the sciatic-tibial, radial, ulnar, and recurrent laryngeal nerves; sciatic-tibial and ulnar F-wave studies; sensory nerve conduction studies of the tibial, ulnar, and radial nerves; and evaluation of blink reflex and facial responses were performed before and 6, 12, and 18 months after induction of hypothyroidism and compared with controls. Clinical evidence of peripheral nervous dysfunction did not occur in any dog. At 6 month and subsequent evaluations, all hypothyroid dogs had EMG and histologic evidence of hypothyroid myopathy. Hypothyroid dogs had significant (Pmuscle action potentials over time, which were attributed to the concurrent myopathy. No significant differences between control and hypothyroid dogs were detected in electrophysiologic tests of motor (P>or=.1) or sensory nerve conduction velocity (P>or=.24) or nerve roots (P>or=.16) throughout the study period, with values remaining within reference ranges in all dogs. Chronic hypothyroidism induced by thyroid irradiation does not result in clinical or electrophysiologic evidence of peripheral neuropathy, but does cause subclinical myopathy.

  4. Manifest rotation symmetric expressions for angular momentum eigenfunctions

    International Nuclear Information System (INIS)

    Eeg, J.O.; Wroldsen, J.

    1983-01-01

    Manifest rotation symmetric expressions for eigenfunctions for spin s, orbital angular momentum l and total angular momentum j = l+s, .... , /l-s/ in terms of (2j+1) x (2s+1) multipole transition matrices (MTM) is given. These matrices, which are irreducible tensor matrices, have an algebra together with ordinary spin matrices for spin s and spin j. Explicit expressions for MTM's and their algebra are given for angular momenta <-3. By means of some examples it is shown that within this formalism angular integrations in central field problems will be simplified considerably. Thus the formalism turns out to be very useful for instance for calculations within the MIT-bag and also within spin-spin interactions in atomic physics. (Auth.)

  5. The angular momentum dependence of complex fragment emission

    International Nuclear Information System (INIS)

    Sobtka, L.G.; Sarantites, D.G.; Li, Z.

    1987-01-01

    Large fragment (A > 4) production at high angular momentum is studied via the reaction, 200 MeV 45 Sc + 65 Cu. Comparisons of the fragment yields from this reaction (high angular momentum) to those from 93 Nb + Be (low angular momentum) are used to verify the strong angular momentum dependence of large fragment production predicted by equilibrium models. Details of the coincident γ-ray distributions not only confirm a rigidly rotating intermediate but also indicate that the widths of the primary L-wave distributions decrease with increasing symmetry in the decay channel. These data are used to test the asymmetry and L-wave dependence of emission barriers calculated from a rotating, finite range corrected, liquid drop model. 21 refs., 10 figs

  6. Triple system HD 201433 with a SPB star component seen by BRITE - Constellation: Pulsation, differential rotation, and angular momentum transfer

    Science.gov (United States)

    Kallinger, T.; Weiss, W. W.; Beck, P. G.; Pigulski, A.; Kuschnig, R.; Tkachenko, A.; Pakhomov, Y.; Ryabchikova, T.; Lüftinger, T.; Palle, , P. L.; Semenko, E.; Handler, G.; Koudelka, O.; Matthews, J. M.; Moffat, A. F. J.; Pablo, H.; Popowicz, A.; Rucinski, S.; Wade, G. A.; Zwintz, K.

    2017-07-01

    Context. Stellar rotation affects the transport of chemical elements and angular momentum and is therefore a key process during stellar evolution, which is still not fully understood. This is especially true for massive OB-type stars, which are important for the chemical enrichment of the Universe. It is therefore important to constrain the physical parameters and internal angular momentum distribution of massive OB-type stars to calibrate stellar structure and evolution models. Stellar internal rotation can be probed through asteroseismic studies of rotationally split non radial oscillations but such results are still quite rare, especially for stars more massive than the Sun. The slowly pulsating B9V star HD 201433 is known to be part of a single-lined spectroscopic triple system, with two low-mass companions orbiting with periods of about 3.3 and 154 days. Aims: Our goal is to measure the internal rotation profile of HD 201433 and investigate the tidal interaction with the close companion. Methods: We used probabilistic methods to analyse the BRITE - Constellation photometry and radial velocity measurements, to identify a representative stellar model, and to determine the internal rotation profile of the star. Results: Our results are based on photometric observations made by BRITE - Constellation and the Solar Mass Ejection Imager on board the Coriolis satellite, high-resolution spectroscopy, and more than 96 yr of radial velocity measurements. We identify a sequence of nine frequency doublets in the photometric time series, consistent with rotationally split dipole modes with a period spacing of about 5030 s. We establish that HD 201433 is in principle a solid-body rotator with a very slow rotation period of 297 ± 76 days. Tidal interaction with the inner companion has, however, significantly accelerated the spin of the surface layers by a factor of approximately one hundred. The angular momentum transfer onto the surface of HD 201433 is also reflected by the

  7. MR arthrography of elbow: evaluation of the ulnar collateral ligament of elbow

    International Nuclear Information System (INIS)

    Nakanishi, Katsunuki; Masatomi, Takashi; Ochi, Takahiro; Ishida, Takeshi; Hori, Shinichi; Ikezoe, Junpei; Nakamura, Hironobu

    1996-01-01

    Objective. The purpose of this study was to evaluate ulnar collateral ligament (UCL) injury of the elbow in throwing athletes by MRI and MR arthrography. Design. Ten elbows of throwing athletes were examined on both plain MRI and MR saline arthrography and the injuries subsequently surgically proven. Spin-echo (SE) T1-weighted and fast SE T2-weighted coronal images were obtained. Results. The UCL was unclear in all ten cases on T1-weighted MRI. In five cases an avulsion fracture was also found on T1-weighted MRI. On T2-weighted MRI, abnormal high-intensity areas were identified in or around the UCL. On T2-weighted MR arthrography images, extracapsular high-intensity areas, which represent extracapsular leakage, were found in four of five cases with avulsion fracture. At surgery, all these four cases showed avulsion fractures with instability; the other case had a fracture but it was stable and adherent to the humerus. On T2-weighted MR arthrography images, an extracapsular high-intensity area was found in one of the five cases without avulsion fracture. At surgery this patient had a complete tear of the UCL itself. Conclusion. MR arthrography provided additional information for evaluating the degree of UCL injury. (orig.). With 5 figs., 1 tab

  8. Neglected Monteggia fracture dislocations in children: a systematic review.

    Science.gov (United States)

    Goyal, Tarun; Arora, Shobha S; Banerjee, Sumit; Kandwal, Pankaj

    2015-05-01

    Monteggia fractures are uncommon and frequently missed injuries in children. This article aims to study, in a systematic manner, the surgical management and complications of treatment of chronic radial head dislocations. After screening of relevant abstracts, a total of 28 studies were included in the systematic review. A narrative synthesis of various treatment modalities has been discussed. This article concludes that open reduction should be attempted unless dysmorphism of the radial head restricts it. Open reduction with ulnar osteotomy with or without annular ligament reconstruction is the most commonly performed procedure and is expected to result in reduced pain and elbow deformity.

  9. TBX3 regulates splicing in vivo: a novel molecular mechanism for Ulnar-mammary syndrome.

    Directory of Open Access Journals (Sweden)

    Pavan Kumar P

    2014-03-01

    Full Text Available TBX3 is a member of the T-box family of transcription factors with critical roles in development, oncogenesis, cell fate, and tissue homeostasis. TBX3 mutations in humans cause complex congenital malformations and Ulnar-mammary syndrome. Previous investigations into TBX3 function focused on its activity as a transcriptional repressor. We used an unbiased proteomic approach to identify TBX3 interacting proteins in vivo and discovered that TBX3 interacts with multiple mRNA splicing factors and RNA metabolic proteins. We discovered that TBX3 regulates alternative splicing in vivo and can promote or inhibit splicing depending on context and transcript. TBX3 associates with alternatively spliced mRNAs and binds RNA directly. TBX3 binds RNAs containing TBX binding motifs, and these motifs are required for regulation of splicing. Our study reveals that TBX3 mutations seen in humans with UMS disrupt its splicing regulatory function. The pleiotropic effects of TBX3 mutations in humans and mice likely result from disrupting at least two molecular functions of this protein: transcriptional regulation and pre-mRNA splicing.

  10. TBX3 regulates splicing in vivo: a novel molecular mechanism for Ulnar-mammary syndrome.

    Science.gov (United States)

    Kumar P, Pavan; Franklin, Sarah; Emechebe, Uchenna; Hu, Hao; Moore, Barry; Lehman, Chris; Yandell, Mark; Moon, Anne M

    2014-03-01

    TBX3 is a member of the T-box family of transcription factors with critical roles in development, oncogenesis, cell fate, and tissue homeostasis. TBX3 mutations in humans cause complex congenital malformations and Ulnar-mammary syndrome. Previous investigations into TBX3 function focused on its activity as a transcriptional repressor. We used an unbiased proteomic approach to identify TBX3 interacting proteins in vivo and discovered that TBX3 interacts with multiple mRNA splicing factors and RNA metabolic proteins. We discovered that TBX3 regulates alternative splicing in vivo and can promote or inhibit splicing depending on context and transcript. TBX3 associates with alternatively spliced mRNAs and binds RNA directly. TBX3 binds RNAs containing TBX binding motifs, and these motifs are required for regulation of splicing. Our study reveals that TBX3 mutations seen in humans with UMS disrupt its splicing regulatory function. The pleiotropic effects of TBX3 mutations in humans and mice likely result from disrupting at least two molecular functions of this protein: transcriptional regulation and pre-mRNA splicing.

  11. Angular momentum conservation for uniformly expanding flows

    International Nuclear Information System (INIS)

    Hayward, Sean A

    2007-01-01

    Angular momentum has recently been defined as a surface integral involving an axial vector and a twist 1-form, which measures the twisting around the spacetime due to a rotating mass. The axial vector is chosen to be a transverse, divergence-free, coordinate vector, which is compatible with any initial choice of axis and integral curves. Then a conservation equation expresses the rate of the change of angular momentum along a uniformly expanding flow as a surface integral of angular momentum densities, with the same form as the standard equation for an axial Killing vector, apart from the inclusion of an effective energy tensor for gravitational radiation

  12. Inefficient Angular Momentum Transport in Accretion Disk Boundary Layers: Angular Momentum Belt in the Boundary Layer

    Science.gov (United States)

    Belyaev, Mikhail A.; Quataert, Eliot

    2018-04-01

    We present unstratified 3D MHD simulations of an accretion disk with a boundary layer (BL) that have a duration ˜1000 orbital periods at the inner radius of the accretion disk. We find the surprising result that angular momentum piles up in the boundary layer, which results in a rapidly rotating belt of accreted material at the surface of the star. The angular momentum stored in this belt increases monotonically in time, which implies that angular momentum transport mechanisms in the BL are inefficient and do not couple the accretion disk to the star. This is in spite of the fact that magnetic fields are advected into the BL from the disk and supersonic shear instabilities in the BL excite acoustic waves. In our simulations, these waves only carry a small fraction (˜10%) of the angular momentum required for steady state accretion. Using analytical theory and 2D viscous simulations in the R - ϕ plane, we derive an analytical criterion for belt formation to occur in the BL in terms of the ratio of the viscosity in the accretion disk to the viscosity in the BL. Our MHD simulations have a dimensionless viscosity (α) in the BL that is at least a factor of ˜100 smaller than that in the disk. We discuss the implications of these results for BL dynamics and emission.

  13. Nature of the many-particle potential in the monatomic liquid state: Radial and angular structure

    International Nuclear Information System (INIS)

    Clements, B.E.; Wallace, D.C.

    1999-01-01

    The atomic configurational order of random, symmetric, and crystalline states of sodium is investigated using molecular-dynamics simulations. Pair distribution functions are calculated for these states. Consistent with the liquid- and random-state energetics, we find that, by cooling, the liquid configurations evolve continuously to random-state structures. For sodium, the random pair distribution function has a split second peak characteristic of many amorphous materials and has the first subpeak exceeding the second subpeak. Experiments have shown this to be the case for amorphous Ni, Co, Cr, Fe, and Mn. A universal pair distribution function is identified for all random structures, as was hypothesized by liquid-dynamics theory. The peak widths of the random pair distribution function are considerably broader, even at very low temperatures, than those of the bcc and symmetric structures. No universal pair distribution function exists for symmetric structures. For low-temperature random, symmetric, and crystalline structures we determine average Voronoi coordination numbers, angular distributions between neighboring atomic triplets, and the number of Voronoi edges per face. Without exception the random and symmetric structures show very different trends for each of these properties. The universal nature of the random structures is also apparent in each property exhibited in the Voronoi polyhedra, unlike for the symmetric structures. Angles between neighboring Voronoi triplets common to random close-packing structures are favored by the random structures whereas those hinting at microcrystalline order are found for the symmetric structures. The distribution of Voronoi coordination numbers for both random and symmetric structures are peaked at 14 neighbors, but while the symmetric structures are essentially all 14, the random structures have nearly as many 13 and 15 neighbor polyhedra. The number of edges per face also shows a stark difference between the random and

  14. The effects of medial ulnar collateral ligament reconstruction on Major League pitching performance.

    Science.gov (United States)

    Keller, Robert A; Steffes, Matthew J; Zhuo, David; Bey, Michael J; Moutzouros, Vasilios

    2014-11-01

    Medial ulnar collateral ligament (MUCL) reconstruction is commonly performed on Major League Baseball (MLB) pitchers. Previous studies have reported that most pitchers return to presurgical statistical performance levels after MUCL reconstruction. Pitching performance data--specifically, earned run average (ERA), walks and hits per inning pitched (WHIP), winning percentage, and innings pitched--were acquired for 168 MLB pitchers who had undergone MUCL reconstruction. These data were averaged over the 3 years before surgery and the 3 years after surgery and also acquired from 178 age-matched, uninjured MLB pitchers. Of the pitchers who had MUCL reconstruction surgery, 87% returned to MLB pitching. However, compared with presurgical data, pitching performance declined in terms of ERA (P = .001), WHIP (P = .011), and innings pitched (P = .026). Pitching performance also declined in the season before the surgery compared with previous years (ERA, P = .014; WHIP, P = .036; innings pitched, P risk factor for requiring surgery. In addition, there is an increased risk of MUCL reconstruction for pitchers who enter the major leagues at a younger age. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. Angular cheilitis: A clinical and microbial study

    Directory of Open Access Journals (Sweden)

    Nirima Oza

    2017-01-01

    Full Text Available Aims: The aim of the present study was to examine clinical types and microbiological flora isolated from angular chelitis. Materials and Methods: An eroded and/or erythematous, with or without fissure formation, nonvesicular lesion radiating from the angle of the mouth was considered to be angular chelitis. A sample of the present study comprised of 40 patients having unilateral or bilateral angular chelitis and 20 healthy individuals without any lip lesions. Clinical examination was done. In both test and control groups, the sample for microbial analysis was obtained from angle of the mouth. Results: Clinically, four types of angular cheilitis lesions were found, Type I, II, III, and IV. The most common type of lesion found was Type I lesion. Microorganisms isolated from the lesion were Staphylococcus aureus, Candida or Streptococci in 33 (82.5% cases either in pure culture or mixed culture. Among these 33 patients, S. aureus was found in 25 (75.5% cases, Candida in 16 (48.4% cases, and Streptococci in 5 (13.5% cases, respectively. Out of 16 cases positive for Candida, in 13 cases further isolation of Candida was possible. Candida albicans was found in 6 cases and Candida stellastodia in 7 cases. In majority of the dentulous and edentulous patients, S. aureus showed profuse growth. Conclusions: There are microorganisms associated with angular cheilitis.

  16. [Instability of the distal radioulnar joint: Treatment options for ulnar lesions of the triangular fibrocartilage complex].

    Science.gov (United States)

    Spies, C K; Prommersberger, K J; Langer, M; Müller, L P; Hahn, P; Unglaub, F

    2015-08-01

    Injuries of the triangular fibrocartilage complex (TFCC) may be fatal to the distal radioulnar joint (DRUJ). This structure is one of the crucial stabilizers and guarantees unrestricted pronosupination of the forearm. A systematic examination is mandatory to diagnose DRUJ instability reliably. A clinical examination in comparison to the contralateral side is obligatory. Plain radiographs are required to exclude osseous lesions or deformities. Computed tomography of both wrists in neutral, pronation and supination is necessary to verify DRUJ instability in ambiguous situations. Based on a systematic examination wrist and DRUJ arthroscopy identify lesions clearly. Injuries of the radioulnar ligaments which entail DRUJ instability, should be reconstructed preferably anatomically. Ulnar-sided TFCC lesions may often cause DRUJ instability. Osseous ligament avulsions are mostly treated osteosynthetically. Ligament tears may be refixated using anchor or transosseous sutures. Tendon transplants are necessary for an anatomical reconstruction in cases of irreparable ruptures.

  17. Radial electric fields for improved tokamak performance

    International Nuclear Information System (INIS)

    Downum, W.B.

    1981-01-01

    The influence of externally-imposed radial electric fields on the fusion energy output, energy multiplication, and alpha-particle ash build-up in a TFTR-sized, fusing tokamak plasma is explored. In an idealized tokamak plasma, an externally-imposed radial electric field leads to plasma rotation, but no charge current flows across the magnetic fields. However, a realistically-low neutral density profile generates a non-zero cross-field conductivity and the species dependence of this conductivity allows the electric field to selectively alter radial particle transport

  18. Mastering AngularJD for .NET developers

    CERN Document Server

    Majid, Mohammad Wadood

    2015-01-01

    This book is envisioned for traditional developers and programmers who want to develop client-side applications using the AngularJS framework and ASP.NET Web API 2 with Visual Studio. .NET developers who have already built web applications or web services and who have a fundamental knowledge of HTML, JavaScript, and CSS and want to explore single-page applications will also find this guide useful. Basic knowledge of AngularJS would be helpful.

  19. Angular Spectra of Polarized Galactic Foregrounds

    OpenAIRE

    Cho, Jung; Lazarian, A.

    2003-01-01

    It is believed that magnetic field lines are twisted and bend by turbulent motions in the Galaxy. Therefore, both Galactic synchrotron emission and thermal emission from dust reflects statistics of Galactic turbulence. Our simple model of Galactic turbulence, motivated by results of our simulations, predicts that Galactic disk and halo exhibit different angular power spectra. We show that observed angular spectra of synchrotron emission are compatible with our model. We also show that our mod...

  20. Quantification of human upper extremity nerves and fascicular anatomy.

    Science.gov (United States)

    Brill, Natalie A; Tyler, Dustin J

    2017-09-01

    In this study we provide detailed quantification of upper extremity nerve and fascicular anatomy. The purpose is to provide values and trends in neural features useful for clinical applications and neural interface device design. Nerve cross-sections were taken from 4 ulnar, 4 median, and 3 radial nerves from 5 arms of 3 human cadavers. Quantified nerve features included cross-sectional area, minor diameter, and major diameter. Fascicular features analyzed included count, perimeter, area, and position. Mean fascicular diameters were 0.57 ± 0.39, 0.6 ± 0.3, 0.5 ± 0.26 mm in the upper arm and 0.38 ± 0.18, 0.47 ± 0.18, 0.4 ± 0.27 mm in the forearm of ulnar, median, and radial nerves, respectively. Mean fascicular diameters were inversely proportional to fascicle count. Detailed quantitative anatomy of upper extremity nerves is a resource for design of neural electrodes, guidance in extraneural procedures, and improved neurosurgical planning. Muscle Nerve 56: 463-471, 2017. © 2016 Wiley Periodicals, Inc.

  1. Efficient evaluation of angular power spectra and bispectra

    Science.gov (United States)

    Assassi, Valentin; Simonović, Marko; Zaldarriaga, Matias

    2017-11-01

    Angular statistics of cosmological observables are hard to compute. The main difficulty is due to the presence of highly-oscillatory Bessel functions which need to be integrated over. In this paper, we provide a simple and fast method to compute the angular power spectrum and bispectrum of any observable. The method is based on using an FFTlog algorithm to decompose the momentum-space statistics onto a basis of power-law functions. For each power law, the integrals over Bessel functions have a simple analytical solution. This allows us to efficiently evaluate these integrals, independently of the value of the multipole l. In particular, this method significantly speeds up the evaluation of the angular bispectrum compared to existing methods. To illustrate our algorithm, we compute the galaxy, lensing and CMB temperature angular power spectrum and bispectrum.

  2. Interactions between Radial Electric Field, Transport and Structure in Helical Plasmas

    International Nuclear Information System (INIS)

    Ida, Katsumi and others

    2006-01-01

    Control of the radial electric field is considered to be important in helical plasmas, because the radial electric field and its shear are expected to reduce neoclassical and anomalous transport, respectively. Particle and heat transport, that determines the radial structure of density and electron profiles, sensitive to the structure of radial electric field. On the other hand, the radial electric field itself is determined by the plasma parameters. In general, the sign of the radial electric field is determined by the plasma collisionality, while the magnitude of the radial electric field is determined by the temperature and/or density gradients. Therefore the structure of radial electric field and temperature and density are strongly coupled through the particle and heat transport and formation mechanism of radial electric field. Interactions between radial electric field, transport and structure in helical plasmas is discussed based on the experiments on Large Helical Device

  3. Anomalous Medial Branch of Radial Artery: A Rare Variant

    Directory of Open Access Journals (Sweden)

    Surbhi Wadhwa

    2016-10-01

    Full Text Available Radial artery is an important consistent vessel of the upper limb. It is a useful vascular access site for coronary procedures and its reliable anatomy has resulted in an elevation of radial forearm flaps for reconstructive surgeries of head and neck. Technical failures, in both the procedures, are mainly due to anatomical variations, such as radial loops, ectopic radial arteries or tortuosity in the vessel. We present a rare and a unique anomalous medial branch of the radial artery spiraling around the flexor carpi radialis muscle in the forearm with a high rising superficial palmar branch of radial artery. Developmentally it probably is a remanent of the normal pattern of capillary vessel maintenance and regression. Such a case is of importance for reconstructive surgeons and coronary interventionists, especially in view of its unique medial and deep course.

  4. What happens to the triangular fibrocartilage complex during pronation and supination of the forearm? Analysis of its morphology and diagnostic assessment with MR arthrography

    Energy Technology Data Exchange (ETDEWEB)

    Pfirrmann, C.W.A. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Dept. of Radiology, Orthopedic University Hospital Balgrist, Zurich (Switzerland); Theumann, N.H. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Service de Radiologie, CHUV, Lausanne (Switzerland); Chung, C.B.; Trudell, D.J.; Resnick, D. [Dept. of Radiology, Veterans Administration Medical Center, San Diego, CA (United States); Botte, M.J. [Div. of Orthopedic Surgery, Scripps Clinic and Research Foundation, La Jolla, CA (United States)

    2001-12-01

    Objective: To evaluate the dynamic morphologic changes of the triangular fibrocartilage complex (TFCC) during pronation and supination of the forearm using high-resolution MR arthrography in cadavers and to evaluate the impact of these changes on the diagnostic assessment of the normal and abnormal TFCC. Design and specimens: High-resolution MR arthrography of 10 wrists of cadaveric specimens was obtained in maximum pronation, in the neutral position, and in maximum supination of the forearm. The structures of the TFCC were evaluated by two musculoskeletal radiologists and correlated with anatomic sections. The position of the forearm that allowed the best visualization of normal structures and lesions of the TFCC was determined. Results: The shape and extent of the articular disc as well as the radial portions of the radioulnar ligaments did not change with pronation and supination. The articular disc was horizontal in the neutral position and tilted more distally to align with the proximal carpal row in pronation and supination. The fibers of the ulnar part of the radioulnar ligaments (ulnar attachment of the articular disc) revealed the most significant changes: their orientation was coronal in the neutral position and sagittal in positions of pronation and supination. The ulnomeniscal homologue was largest in the neutral position and was reduced in size during pronation and supination. The extensor carpi ulnaris tendon was centered in its groove in the neutral position and pronation. In supination this tendon revealed subluxation from this groove. The dorsal capsule of the distal radioulnar joint was taut in pronation, and the palmar capsule was taut in supination. The preferred forearm position for analysis of most of the structures of the TFCC was the neutral position, followed by the pronated position. The neutral position was rated best for the detection of ulnar and radial detachments of the TFCC, followed by the pronated position, except for two central

  5. Fuel radial design using Path Relinking; Diseno radial de combustible usando Path Relinking

    Energy Technology Data Exchange (ETDEWEB)

    Campos S, Y. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The present work shows the obtained results when implementing the combinatory optimization technique well-known as Path Re linking (Re-linkage of Trajectories), to the problem of the radial design of nuclear fuel assemblies, for boiling water reactors (BWR Boiling Water Reactor by its initials in English), this type of reactors is those that are used in the Laguna Verde Nucleo electric Central, Veracruz. As in any other electric power generation plant of that make use of some fuel to produce heat and that it needs each certain time (from 12 to 14 months) to make a supply of the same one, because this it wears away or it burns, in the nucleolectric plants to this activity is denominated fuel reload. In this reload different activities intervene, among those which its highlight the radial and axial designs of fuel assemblies, the patterns of control rods and the multi cycles study, each one of these stages with their own complexity. This work was limited to study in independent form the radial design, without considering the other activities. These phases are basic for the fuel reload design and of reactor operation strategies. (Author)

  6. Angular dispersion and deflection function for heavy ion elastic scattering

    International Nuclear Information System (INIS)

    Bai Zhen; Han Jianlong; Hu Zhengguo; Chinese Academy of Sciences, Beijing

    2007-01-01

    The differential cross sections for elastic scattering products of 17 F on 208 Pb have been measured. The angular dispersion plots of ln(dσ/dθ) versus θ 2 are obtained from the angular distribution of the elastic scattering differential cross sections. Systematical analysis on the angular dispersion for the available experimental data indicates that there is an angular dispersion turning angle at forward angular range within the grazing angle. This turning angle can be clarified as nuclear rainbow in classical deflection function. The exotic behaviour of the nuclear rainbow angle offers a new probe to investigate the halo and skin phenomena. (authors)

  7. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    International Nuclear Information System (INIS)

    De Maeseneer, Michel; Brigido, Monica Kalume; Antic, Marijana; Lenchik, Leon; Milants, Annemieke; Vereecke, Evie; Jager, Tjeerd; Shahabpour, Maryam

    2015-01-01

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  8. Ultrasound of the elbow with emphasis on detailed assessment of ligaments, tendons, and nerves

    Energy Technology Data Exchange (ETDEWEB)

    De Maeseneer, Michel, E-mail: Michel.demaeseneer@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Brigido, Monica Kalume, E-mail: Mbrigido@med.umich.edu [Department of Radiology, University of Michigan, Ann Arbor, MI (United States); Antic, Marijana, E-mail: Misscroa@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Lenchik, Leon, E-mail: Llenchik@wakehealth.edu [Department of Radiology, Wake Forest University, Winston-Salem, NC (United States); Milants, Annemieke, E-mail: Annemieke.Milants@gmail.com [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium); Vereecke, Evie, E-mail: Evie.Vereecke@kuleuven-kulak.be [Department of Anatomy, KULAK, Katholieke Universiteit Leuven, Campus Kortrijk, Kortrijk (Belgium); Jager, Tjeerd [Aalsters Stedelijk Ziekenhuis, Aalst (Belgium); Shahabpour, Maryam, E-mail: Maryam.Shahabpour@uzbrussel.be [Department of Radiology, Universitair Ziekenhuis Brussel, Brussels (Belgium)

    2015-04-15

    Highlights: •Medial and lateral tendons: the different muscles forming these tendons can be followed up to the insertion. The imaging anatomy is reviewed. •Medial and lateral ligaments: the anatomy is complex and specialized imaging planes and arm positions are necessary for accurate assessment. •Biceps tendon: the anatomy of the distal biceps and lacertus fibrosus are discussed and illustrated with cadaveric correlation. •US imaging of the nerves about the elbow and visualization of the possible compression points is discussed. -- Abstract: The high resolution and dynamic capability of ultrasound make it an excellent tool for assessment of superficial structures. The ligaments, tendons, and nerves about the elbow can be fully evaluated with ultrasound. The medial collateral ligament consists of an anterior and posterior band that can easily be identified. The lateral ligament complex consists of the radial collateral ligament, ulnar insertion of the annular ligament, and lateral ulnar collateral ligament, easily identified with specialized probe positioning. The lateral ulnar collateral ligament can best be seen in the cobra position. On ultrasound medial elbow tendons can be followed nearly up to their common insertion. The pronator teres, flexor carpi radialis, palmaris longus, and flexor digitorum superficialis can be identified. The laterally located brachioradialis and extensor carpi radialis longus insert on the supracondylar ridge. The other lateral tendons can be followed up to their common insertion on the lateral epicondyle. The extensor digitorum, extensor carpi radialis brevis, extensor digiti minimi, and extensor carpi ulnaris can be differentiated. The distal biceps tendon is commonly bifid. For a complete assessment of the distal biceps tendon specialized views are necessary. These include an anterior axial approach, medial and lateral approach, and cobra position. In the cubital tunnel the ulnar nerve is covered by the ligament of Osborne

  9. [Treatment of triangular fibrocartilage complex tear under wrist arthroscopy].

    Science.gov (United States)

    Mi, Kun; Liu, Wu; Liu, Pengfei; Feng, Zhibin; Li, Yuwen; Hui, Guisheng

    2011-01-01

    To evaluate the treatment and effects of wrist arthroscopy in tear of triangular fibrocartilage complex (TFCC). Between January 2006 and December 2008, 16 patients with tear of TFCC were treated. Of 16 patients, 11 were male and 5 were female with an average age of 32.5 years (range, 25-51 years). Injury was caused by sprain in 12 cases, and by falling in 4 cases. The locations were the left side in 10 cases and the right side in 6 cases. The mean injury duration was 3 months to 6 years and 2 months. The main clinical symptoms included wrist powerlessness and ulnar-sided wrist pain which was aggravated with clench fist and lifting heavy things. The results of the ulnar-sided wrist stress test were positive in 14 cases and negative in 2 cases. The preoperative values of wrist range of motion (ROM) were (45.58 +/- 5.18) degrees at volar flexion, (41.22 +/- 3.83) degrees at dorsal extension, (17.82 +/- 2.48) degrees at radial deviation, (21.35 +/- 4.61) degrees at ulnar deviation, (69.85 +/- 8.36) degrees at pronation, and (70.13 +/- 6.34) degrees at supination. According to Palmer standard, 10 cases of IA were treated with debridement; 3 cases of IB with suture and 1 of them failed and was partially excised; 2 cases of IC with debridement on triangular fibrocartilage disc, ulnolunate ligament, and ulnotriguetrum ligament; and 1 case of ID with trimming plastic operation. All incisions healed by first intention, and no complications of joint infection or neurovascular injury was found. All patients were followed up 14-38 months (mean, 18.5 months). Fifteen patients were restored to normal life and work without ulnar-sided wrist pain. One patient had no pain, but he had wrist powerless. The values of ROM at last follow-up were (50.16 +/- 6.21) degrees at volar flexion, (45.37 +/- 4.65) degrees at dorsal extension, (18.95 +/- 3.56) degrees at radial deviation, (26.28 +/- 5.09) degrees at ulnar deviation, (78.87 +/- 7.69) degrees at pronation, and (76.46 +/- 8

  10. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Science.gov (United States)

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  11. Frame dependence of spin-one angular conditions in light front dynamics

    International Nuclear Information System (INIS)

    Bakker, Bernard L. G.; Ji Chuengryong

    2002-01-01

    We elaborate the frame dependence of the angular conditions for spin-1 form factors. An extra angular condition is found in addition to the usual angular condition relating the four helicity amplitudes. Investigating the frame dependence of angular conditions, we find that the extra angular condition is in general as complicated as the usual one, although it becomes very simple in the q + =0 frame involving only two helicity amplitudes. It is confirmed that the angular conditions are identical in frames that are connected by kinematical transformations. The high-Q 2 behavior of the physical form factors and the limiting behavior in special reference frames are also discussed

  12. On the angular momentum in star formation

    International Nuclear Information System (INIS)

    Horedt, G.P.

    1978-01-01

    The author discusses the rotation of interstellar clouds which are in a stage immediately before star formation. Cloud collisions seem to be the principal cause of the observed rotation of interstellar clouds. The rotational motion of the clouds is strongly influenced by turbulence. Theories dealing with the resolution of the angular momentum problem in star formation are classified into five major groups. The old idea that the angular momentum of an interstellar cloud passes during star formation into the angular momentum of double star systems and/or circumstellar clouds, is developed. It is suggested that a rotating gas cloud contracts into a ring-like structure which fragments into self-gravitating subcondensations. By collisions and gas accretion these subcondensations accrete into binary systems surrounded by circumstellar clouds. Using some rough approximations the authors find analytical expressions for the semi-major axis of the binary system and for the density of the circumstellar clouds as a function of the initial density and of the initial angular velocity of an interstellar cloud. The obtained values are well within the observational limits. (Auth.)

  13. [Classification and MR imaging of triangular fibrocartilage complex lesions].

    Science.gov (United States)

    Zhan, H L; Liu, Y; Bai, R J; Qian, Z H; Ye, W; Li, Y X; Wu, B D

    2016-06-07

    To explore the MRI characteristics of injuries of triangular fibrocartilage complex (TFCC), and provide imaging basis for the early diagnosis and treatment of the injuries. A total of 10 healthy volunteers without wrist injuries and 200 patients from Beijing Jishuitan Hospital who complained ulnar-sided wrist pain and were highly suspected as the injury of TFCC underwent the wrist magnetic resonance examination. All subjects were in a prone position and underwent examination on coronal T1WI scan and PD-FS on 3 planes respectively. Then the MRI characteristics of 3 healthy volunteers and 67 patients with TFCC injuries that confirmed by operation were analyzed. According to the comparative analysis of normal anatomy and Palmer classification, the injuries were classified and MRI features of different types of injuries were analyzed. At last, imaging findings were compared with surgical results. Three healthy volunteers without injuries showed mainly in low signal intensity on T1WI and PD-FS images. According to Palmer classification, there were 52 traumatic injuries (ⅠA 9, ⅠB 25, ⅠC 3, ⅠD 13, In addition, 1 has central perforation and ulnar avulsion and 1 has ulnar and radial injuries simultaneously) and 15 degenerative injuries (ⅡA 5, ⅡB 1, ⅡC 2 , ⅡD 1 , ⅡE 6) among 67 patients. The central perforation mainly demonstrated as linear high signal perpendicular to the disk, and run in a sagittal line. The ulnar, distal, and radial avulsion mainly showed the injuries were irregular, the structures were ambiguous, and there was high signal intensity in the injured structures on PD-FS. Degenerative injuries demonstrated the irregularity of TFC and heterogeneous signals on PD-FS. There were mixed intermediate-high signals and changes in the articular cartilage of lunate and ulna, high signal in the lunotriquetral ligament and ulnocarpal or radioulnar arthritis. MRI can demonstrate the anatomy of TFCC accurately, evaluate and make the general classification

  14. ANGULAR LIGHT-SCATTERING STUDIES ON ISOLATED MITOCHONDRIA

    Science.gov (United States)

    Gotterer, Gerald S.; Thompson, Thomas E.; Lehninger, Albert L.

    1961-01-01

    Angular light-scattering studies have been carried out on suspensions of isolated rat liver mitochondria. The angular scatter pattern has a large forward component, typical of large particles. Changes in dissymmetry and in the intensity of light scattered at 90° have been correlated with changes in optical density during the course of mitochondrial swelling and contraction. Such changes can be measured at mitochondrial concentrations much below those required for optical density measurements. Changes in mitochondrial geometry caused by factors "leaking" from mitochondria, not detectable by optical density measurements, have been demonstrated by measuring changes in dissymmetry. Angular light-scattering measurements therefore offer the advantages of increased sensitivity and of added indices of changes in mitochondrial conformation. PMID:19866589

  15. Vitreous veils and radial lattice in Marshall syndrome.

    Science.gov (United States)

    Brubaker, Jacob W; Mohney, Brian G; Pulido, Jose S; Babovic-Vuksanovic, Dusica

    2008-12-01

    To report the findings of membranous vitreous veils and radial lattice in a child with Marshall syndrome. Observational case report. Retrospective review of medical records and fundus photograph of a 6-year-old boy with Marshall syndrome. Vitreoretinal findings were significant for bilateral membranous vitreous veils and radial lattice degeneration. This case demonstrates the occurrence of vitreous veils and radial lattice degeneration in patients with Marshall syndrome.

  16. Long-Term Follow-up of Modular Metallic Radial Head Replacement: Commentary on an article by Jonathan P. Marsh, MD, FRCSC, et al.: "Radial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years".

    OpenAIRE

    Mansat, Pierre

    2016-01-01

    Radial head arthroplasty is used to stabilize the joint after a complex acute radial head fracture that is not amenable for fixation or to treat sequelae of radial head fractures. Most of the currently used radial head prostheses are metallic monoblock implants that are not consistently adaptable and raise technical challenges since their implantation requires lateral elbow subluxation. Metallic modular radial head arthroplasty implants available in various head and stem sizes have been devel...

  17. Angular correlations and high energy evolution

    International Nuclear Information System (INIS)

    Kovner, Alex; Lublinsky, Michael

    2011-01-01

    We address the question of to what extent JIMWLK evolution is capable of taking into account angular correlations in a high energy hadronic wave function. Our conclusion is that angular (and indeed other) correlations in the wave function cannot be reliably calculated without taking into account Pomeron loops in the evolution. As an example we study numerically the energy evolution of angular correlations between dipole scattering amplitudes in the framework of the large N c approximation to JIMWLK evolution (the 'projectile dipole model'). Target correlations are introduced via averaging over an (isotropic) ensemble of anisotropic initial conditions. We find that correlations disappear very quickly with rapidity even inside the saturation radius. This is in accordance with our physical picture of JIMWLK evolution. The actual correlations inside the saturation radius in the target QCD wave function, on the other hand, should remain sizable at any rapidity.

  18. The multiplicity of massive stars: A high angular resolution survey with the HST fine guidance sensor

    International Nuclear Information System (INIS)

    Aldoretta, E. J.; Gies, D. R.; Henry, T. J.; Jao, W.-C.; Norris, R. P.

    2015-01-01

    We present the results of an all-sky survey made with the Fine Guidance Sensor on the Hubble Space Telescope to search for angularly resolved binary systems among massive stars. The sample of 224 stars is comprised mainly of Galactic O- and B-type stars and luminous blue variables, plus a few luminous stars in the Large Magellanic Cloud. The FGS TRANS mode observations are sensitive to the detection of companions with an angular separation between 0.″01 and 1.″0 and brighter than △m=5. The FGS observations resolved 52 binary and 6 triple star systems and detected partially resolved binaries in 7 additional targets (43 of these are new detections). These numbers yield a companion detection frequency of 29% for the FGS survey. We also gathered literature results on the numbers of close spectroscopic binaries and wider astrometric binaries among the sample, and we present estimates of the frequency of multiple systems and the companion frequency for subsets of stars residing in clusters and associations, field stars, and runaway stars. These results confirm the high multiplicity fraction, especially among massive stars in clusters and associations. We show that the period distribution is approximately flat in increments of logP. We identify a number of systems of potential interest for long-term orbital determinations, and we note the importance of some of these companions for the interpretation of the radial velocities and light curves of close binaries that have third companions.

  19. Generation of angular-momentum-dominated electron beams from a photoinjector

    International Nuclear Information System (INIS)

    Sun, Yin-E.; Piot, Philippe; Kim, Kwang-Je; Barov, Nikolas; Lidia, Steven; Santucci, James; Tikhoplav, Rodion; Wennerberg, Jason

    2004-01-01

    Various projects under study require an angular-momentum-dominated electron beam generated by a photoinjector. Some of the proposals directly use the angular-momentum-dominated beams (e.g. electron cooling of heavy ions), while others require the beam to be transformed into a flat beam (e.g. possible electron injectors for light sources and linear colliders). In this paper, we report our experimental study of an angular-momentum-dominated beam produced in a photoinjector, addressing the dependencies of angular momentum on initial conditions. We also briefly discuss the removal of angular momentum. The results of the experiment, carried out at the Fermilab/NICADD Photoinjector Laboratory, are found to be in good agreement with theoretical and numerical models

  20. Nuclear spin measurement using the angular correlation method

    International Nuclear Information System (INIS)

    Schapira, J.-P.

    The double angular correlation method is defined by a semi-classical approach (Biendenharn). The equivalence formula in quantum mechanics are discussed for coherent and incoherent angular momentum mixing; the correlations are described from the density and efficiency matrices (Fano). The ambiguities in double angular correlations can be sometimes suppressed (emission of particles with a high orbital momentum l), using triple correlations between levels with well defined spin and parity. Triple correlations are applied to the case where the direction of linear polarization of γ-rays is detected [fr

  1. Notes on the quantum theory of angular momentum

    CERN Document Server

    Feenberg, Eugene

    1999-01-01

    This classic, concise text has served a generation of physicists as an exceptionally useful guide to the mysteries of angular momenta and Clebsch-Gordon Coefficients. Derived from notes originally prepared to assist graduate students in reading research papers on atomic, molecular, and nuclear structure, the text first reviews the basic elements of quantum theory. It then examines the development of the fundamental commutation relations for angular momentum components and vector operators, and the ways in which matrix elements and eigenvalues of the angular momentum operators are worked out f

  2. Unique negative permittivity of the pseudo conducting radial zinc oxide-poly(vinylidene fluoride) nanocomposite film: Enhanced dielectric and electromagnetic interference shielding properties

    Energy Technology Data Exchange (ETDEWEB)

    Aepuru, Radhamanohar [Department of Materials Engineering, Defence Institute of Advanced Technology, Girinagar, Pune 411025 (India); Bhaskara Rao, B.V.; Kale, S.N. [Department of Applied Physics, Defence Institute of Advanced Technology, Pune 411025 (India); Panda, H.S., E-mail: himanshusp@diat.ac.in [Department of Materials Engineering, Defence Institute of Advanced Technology, Girinagar, Pune 411025 (India)

    2015-11-01

    Flower like radial zinc oxide (RZnO) was prepared by using a facile solvothermal method and used to prepare poly(vinylidene fluoride) (PVDF) based nanocomposites. Structural informations of the samples are analyzed by X-ray diffraction and correlated with high resolution transmission electron microscopy along with high annular angular dark field scanning transmission electron microscopy (HAADF-STEM). For the first time, stability studies are carried out by solvent relaxation nuclear magnetic resonance experiments. Dielectric studies of the PVDF and PVDF-RZnO nanocomposites are reported over the wide range of frequency (0.01 Hz–1 MHz) and temperature (25–90 °C). Dielectric property of the PVDF-RZnO nanocomposites was significantly improved wrt filler percentage in PVDF. Unique negative permittivity was observed in the composites having higher filler content (>40 wt%) typically at low frequencies. First time, it is observed that the higher RZnO content in PVDF results the formation of pseudo conducting network and hence improved the electromagnetic shielding efficiency (85%) than PVDF and PVDF-commercial ZnO composites. - Highlights: • Radial ZnO-PVDF nanocomposites were fabricated by using solution casting. • Pseudo conducting network is confirmed through cryo-fracture morphology study. • Stability study of the nano fillers was performed in the polymer matrix. • Unique negative permittivity behavior of the nanocomposites was observed. • EMI shielding property of the radial ZnO-PVDF nanocomposites was performed.

  3. Radial head fracture associated with posterior interosseous nerve injury

    Directory of Open Access Journals (Sweden)

    Bernardo Barcellos Terra

    Full Text Available ABSTRACT Fractures of the radial head and radial neck correspond to 1.7-5.4% of all fractures and approximately 30% may present associated injuries. In the literature, there are few reports of radial head fracture with posterior interosseous nerve injury. This study aimed to report a case of radial head fracture associated with posterior interosseous nerve injury. CASE REPORT: A male patient, aged 42 years, sought medical care after falling from a skateboard. The patient related pain and limitation of movement in the right elbow and difficulty to extend the fingers of the right hand. During physical examination, thumb and fingers extension deficit was observed. The wrist extension showed a slight radial deviation. After imaging, it became evident that the patient had a fracture of the radial head that was classified as grade III in the Mason classification. The patient underwent fracture fixation; at the first postoperative day, thumb and fingers extension was observed. Although rare, posterior interosseous nerve branch injury may be associated with radial head fractures. In the present case, the authors believe that neuropraxia occurred as a result of the fracture hematoma and edema.

  4. Radial Field Piezoelectric Diaphragms

    Science.gov (United States)

    Bryant, R. G.; Effinger, R. T., IV; Copeland, B. M., Jr.

    2002-01-01

    A series of active piezoelectric diaphragms were fabricated and patterned with several geometrically defined Inter-Circulating Electrodes "ICE" and Interdigitated Ring Electrodes "ICE". When a voltage potential is applied to the electrodes, the result is a radially distributed electric field that mechanically strains the piezoceramic along the Z-axis (perpendicular to the applied electric field). Unlike other piezoelectric bender actuators, these Radial Field Diaphragms (RFDs) strain concentrically yet afford high displacements (several times that of the equivalent Unimorph) while maintaining a constant circumference. One of the more intriguing aspects is that the radial strain field reverses itself along the radius of the RFD while the tangential strain remains relatively constant. The result is a Z-deflection that has a conical profile. This paper covers the fabrication and characterization of the 5 cm. (2 in.) diaphragms as a function of poling field strength, ceramic thickness, electrode type and line spacing, as well as the surface topography, the resulting strain field and displacement as a function of applied voltage at low frequencies. The unique features of these RFDs include the ability to be clamped about their perimeter with little or no change in displacement, the environmentally insulated packaging, and a highly repeatable fabrication process that uses commodity materials.

  5. Automated Angular Momentum Recoupling Algebra

    Science.gov (United States)

    Williams, H. T.; Silbar, Richard R.

    1992-04-01

    We present a set of heuristic rules for algebraic solution of angular momentum recoupling problems. The general problem reduces to that of finding an optimal path from one binary tree (representing the angular momentum coupling scheme for the reduced matrix element) to another (representing the sub-integrals and spin sums to be done). The method lends itself to implementation on a microcomputer, and we have developed such an implementation using a dialect of LISP. We describe both how our code, called RACAH, works and how it appears to the user. We illustrate the use of RACAH for several transition and scattering amplitude matrix elements occurring in atomic, nuclear, and particle physics.

  6. At Home Photography-Based Method for Measuring Wrist Range of Motion.

    Science.gov (United States)

    Trehan, Samir K; Rancy, Schneider K; Johnsen, Parker H; Hillstrom, Howard J; Lee, Steve K; Wolfe, Scott W

    2017-11-01

    Purpose  To determine the reliability of wrist range of motion (WROM) measurements based on digital photographs taken by patients at home compared with traditional measurements done in the office with a goniometer. Methods  Sixty-nine postoperative patients were enrolled in this study at least 3 months postoperatively. Active and passive wrist flexion/extension and radial/ulnar deviation were recorded by one of the two attending surgeons with a 1-degree resolution goniometer at the last postoperative office visit. Patients were provided an illustrated instruction sheet detailing how to take digital photographic images at home in six wrist positions (active and passive flexion/extension, and radial/ulnar deviation). Wrist position was measured from digital images by both the attending surgeons in a randomized, blinded fashion on two separate occasions greater than 2 weeks apart using the same goniometer. Reliability analysis was performed using the intraclass correlation coefficient to assess agreement between clinical and photography-based goniometry, as well as intra- and interobserver agreement. Results  Out of 69 enrolled patients, 30 (43%) patients sent digital images. Of the 180 digital photographs, only 9 (5%) were missing or deemed inadequate for WROM measurements. Agreement between clinical and photography-based measurements was "almost perfect" for passive wrist flexion/extension and "substantial" for active wrist flexion/extension and radial/ulnar deviation. Inter- and intraobserver agreement for the attending surgeons was "almost perfect" for all measurements. Discussion  This study validates a photography-based goniometry protocol allowing accurate and reliable WROM measurements without direct physician contact. Passive WROM was more accurately measured from photographs than active WROM. This study builds on previous photography-based goniometry literature by validating a protocol in which patients or their families take and submit their own

  7. Angular momentum alignment in molecular beam scattering

    International Nuclear Information System (INIS)

    Treffers, M.A.

    1985-01-01

    It is shown how the angular momentum alignment in a molecular beam can be determined using laser-induced fluorescence in combination with precession of the angular momenta in a magnetic field. After a general analysis of the method, some results are presented to illustrate the possibilities of the method. Experimental data are presented on the alignment production for Na 2 molecules that made a collision induced angular momentum transition. Magnitude as well as direction of the alignment have been determined for scattering with several scattering partners and for a large number of scattering angles and transitions. The last chapter deals with the total alignment production in a final J-state, i.e. without state selection of the initial rotational state. (orig.)

  8. Yksisivuisten web-sovellusten kehittäminen Angular 2 -sovelluskehyksellä

    OpenAIRE

    Kujala, Miika

    2016-01-01

    Yksisivuiset web-sovellukset ovat yleistyneet viime vuosina. Niiden kehityksessä hyödynnetään usein JavaScript-sovelluskehystä. Angular 2 on Google:n kehittämä JavaScript-sovelluskehys. Tämän tutkielman tavoitteena on tarkastella Angular 2 -sovelluskehystä ja sen soveltuvuutta yksisivuisten web-sovellusten ke- hityksessä. Tutkielmassa käydään läpi Angular 2 -sovelluskehyksen ominaisuuksia sekä Angular 2 -sovelluskehyksen käytössä ilmeneviä etuja ja haittoja.

  9. Design and Implementation of a Digital Angular Rate Sensor

    Directory of Open Access Journals (Sweden)

    Zhen Peng

    2010-10-01

    Full Text Available With the aim of detecting the attitude of a rotating carrier, the paper presents a novel, digital angular rate sensor. The sensor consists of micro-sensing elements (gyroscope and accelerometer, signal processing circuit and micro-processor (DSP2812. The sensor has the feature of detecting three angular rates of a rotating carrier at the same time. The key techniques of the sensor, including sensing construction, sensing principles, and signal processing circuit design are presented. The test results show that the sensor can sense rolling, pitch and yaw angular rate at the same time and the measurement error of yaw (or pitch angular rate and rolling rate of the rotating carrier is less than 0.5%.

  10. Angular Accelerating White Light

    CSIR Research Space (South Africa)

    Dudley, Angela L

    2015-08-01

    Full Text Available wavelength dependence. By digitally simulating free-space propagation on the SLM, The authors compare the effects of real and digital propagation on the angular rotation rates of the resulting optical fields for various wavelengths. The development...

  11. Angular momentum dependence of the distribution of shell model eigenenergies

    International Nuclear Information System (INIS)

    Yen, M.K.

    1974-01-01

    In the conventional shell model calculation the many-particle energy matrices are constructed and diagonalized for definite angular momentum and parity. However the resulting set of eigenvalues possess a near normal behavior and hence a simple statistical description is possible. Usually one needs only about four parameters to capture the average level densities if the size of the set is not too small. The parameters are essentially moments of the distribution. But the difficulty lies in the yet unsolved problem of calculating moments in the fixed angular momentum subspace. We have derived a formula to approximate the angular momentum projection dependence of any operator averaged in a shell model basis. This approximate formula which is a truncated series in Hermite polynomials has been proved very good numerically and justified analytically for large systems. Applying this formula to seven physical cases we have found that the fixed angular momentum projection energy centroid, width and higher central moments can be obtained accurately provided for even-even nuclei the even and odd angular momentum projections are treated separately. Using this information one can construct the energy distribution for fixed angular momentum projection assuming normal behavior. Then the fixed angular momentum level densities are deduced and spectra are extracted. Results are in reasonably good agreement with the exact values although not as good as those obtained using exact fixed angular momentum moments. (Diss. Abstr. Int., B)

  12. A Novel Permanent Magnetic Angular Acceleration Sensor

    Directory of Open Access Journals (Sweden)

    Hao Zhao

    2015-07-01

    Full Text Available Angular acceleration is an important parameter for status monitoring and fault diagnosis of rotary machinery. Therefore, we developed a novel permanent magnetic angular acceleration sensor, which is without rotation angle limitations and could directly measure the instantaneous angular acceleration of the rotating system. The sensor rotor only needs to be coaxially connected with the rotating system, which enables convenient sensor installation. For the cup structure of the sensor rotor, it has a relatively small rotational inertia. Due to the unique mechanical structure of the sensor, the output signal of the sensor can be directed without a slip ring, which avoids signal weakening effect. In this paper, the operating principle of the sensor is described, and simulated using finite element method. The sensitivity of the sensor is calibrated by torsional pendulum and angle sensor, yielding an experimental result of about 0.88 mV/(rad·s−2. Finally, the angular acceleration of the actual rotating system has been tested, using both a single-phase asynchronous motor and a step motor. Experimental result confirms the operating principle of the sensor and indicates that the sensor has good practicability.

  13. AngularJS yksisivuisen web-applikaation kehitysalustana

    OpenAIRE

    Karhu, Tuomo

    2015-01-01

    Yksisivuiset web-applikaatiot (SPA-sovellukset) ovat yleistyneet viimeisten kymmenen vuoden aikana, ja näiden avulla on ollut mahdollista tuoda verkkosivuston käyttökokemus lähemmäksi aitojen ohjelmasovellusten vastaavaa. Yksisivuisten web-applikaatioitten kehitystyöhön tarkoitetuista sovelluskehyksistä AngularJS on yksi käytetyimmistä ja suosituimmista. Työn tavoitteena on selvittää miten AngularJS-sovelluskehys soveltuu SPA-sivustojen kehitykseen sovelluskehittäjän näkökulmasta, sekä mi...

  14. CONSTRAINED EVOLUTION OF A RADIALLY MAGNETIZED PROTOPLANETARY DISK: IMPLICATIONS FOR PLANETARY MIGRATION

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Matthew [Department of Physics, University of Toronto, 60 St. George St., Toronto, ON M5S 1A7 (Canada); Thompson, Christopher [Canadian Institute for Theoretical Astrophysics, 60 St. George St., Toronto, ON M5S 3H8 (Canada)

    2015-12-10

    We consider the inner ∼1 AU of a protoplanetary disk (PPD) at a stage where angular momentum transport is driven by the mixing of a radial magnetic field into the disk from a T Tauri wind. Because the radial profile of the imposed magnetic field is well constrained, a constrained calculation of the disk mass flow becomes possible. The vertical disk profiles obtained in Paper I imply a stronger magnetization in the inner disk, faster accretion, and a secular depletion of the disk material. Inward transport of solids allows the disk to maintain a broad optical absorption layer even when the grain abundance becomes too small to suppress its ionization. Thus, a PPD may show a strong mid- to near-infrared spectral excess even while its mass profile departs radically from the minimum-mass solar nebula. The disk surface density is buffered at ∼30 g cm{sup −2}; below this, X-rays trigger magnetorotational turbulence at the midplane strong enough to loft millimeter- to centimeter-sized particles high in the disk, followed by catastrophic fragmentation. A sharp density gradient bounds the inner depleted disk and propagates outward to ∼1–2 AU over a few megayears. Earth-mass planets migrate through the inner disk over a similar timescale, whereas the migration of Jupiters is limited by the supply of gas. Gas-mediated migration must stall outside 0.04 AU, where silicates are sublimated and the disk shifts to a much lower column. A transition disk emerges when the dust/gas ratio in the MRI-active layer falls below X{sub d} ∼ 10{sup −6} (a{sub d}/μm), where a{sub d} is the grain size.

  15. Measurement of angular distribution of cosmic-ray muon fluence rate

    International Nuclear Information System (INIS)

    Lin, Jeng-Wei; Chen, Yen-Fu; Sheu, Rong-Jiun; Jiang, Shiang-Huei

    2010-01-01

    In this work a Berkeley Lab cosmic ray detector was used to measure the angular distribution of the cosmic-ray muon fluence rate. Angular response functions of the detector at each measurement orientation were calculated by using the FLUKA Monte Carlo code, where no energy attenuation was taken into account. Coincidence counting rates were measured at ten orientations with equiangular intervals. The muon angular fluence rate spectrum was unfolded from the measured counting rates associated with the angular response functions using both the MAXED code and the parameter adjusting method.

  16. Angular momentum content of galaxies

    International Nuclear Information System (INIS)

    Shaya, E.J.; Tully, R.B.

    1984-01-01

    A schema of galaxy formation is developed in which the environmental influence of large-scale structure plays a dominant role. This schema was motivated by the observation that the fraction of E and S0 galaxies is much higher in clusters than in low-density regions and by an inference that those spirals that are found in clusters probably have fallen in relatively recently from the low-density regions. It is proposed that the tidal field of the Local Supercluster acts to determine the morphology of galaxies through two complementary mechanisms. In the first place, the supercluster can apply torques to protogalaxies. Galaxies which collapsed while expanding away from the central cluster decoupled from the external tidal field and conserved the angular momentum that they acquired before collapse. Galaxies which formed in the cluster while the cluster collapsed continued to feel the tidal field. In the latter case, the spin of outer collapsing layers can be halted and reversed, and tends to cancel the spin of inner layers. The result is a reduction of the total angular momentum content of the galaxy. In addition, the supercluster tidal field can regulate accretion of fresh material onto the galaxies since the field creates a Roche limit about galaxies and material beyond this limit is lost. Any material that has not collapsed onto a galaxy by the time the galaxy falls into a cluster will be tidally stripped. The angular momentum content of that part of the protogalactic cloud which has not yet collapsed . continues to grow linearly with time due to the continued torquing by the supercluster and neighbors. Galaxies at large distances from the cluster core can continue to accrete this high angular momentum material until the present, but galaxies that enter the cluster are cut off from replenishing material

  17. QCD angular correlations for muon pair production

    International Nuclear Information System (INIS)

    Kajantie, K.; Raitio, R.; Lindfors, J.

    1978-01-01

    Angular distributions of muons are discussed in the framework of a QCD treatment of muon pair production in hadron-hadron collisions. The predicted angular effects are independent of the infrared behavior of QCD. Measuring them will permit one to determine whether the origin of the large transverse momentum of the pair is in the quark transverse momenta or in a constituent-constituent subprocess. (author)

  18. Radial gradient and radial deviation radiomic features from pre-surgical CT scans are associated with survival among lung adenocarcinoma patients.

    Science.gov (United States)

    Tunali, Ilke; Stringfield, Olya; Guvenis, Albert; Wang, Hua; Liu, Ying; Balagurunathan, Yoganand; Lambin, Philippe; Gillies, Robert J; Schabath, Matthew B

    2017-11-10

    The goal of this study was to extract features from radial deviation and radial gradient maps which were derived from thoracic CT scans of patients diagnosed with lung adenocarcinoma and assess whether these features are associated with overall survival. We used two independent cohorts from different institutions for training (n= 61) and test (n= 47) and focused our analyses on features that were non-redundant and highly reproducible. To reduce the number of features and covariates into a single parsimonious model, a backward elimination approach was applied. Out of 48 features that were extracted, 31 were eliminated because they were not reproducible or were redundant. We considered 17 features for statistical analysis and identified a final model containing the two most highly informative features that were associated with lung cancer survival. One of the two features, radial deviation outside-border separation standard deviation, was replicated in a test cohort exhibiting a statistically significant association with lung cancer survival (multivariable hazard ratio = 0.40; 95% confidence interval 0.17-0.97). Additionally, we explored the biological underpinnings of these features and found radial gradient and radial deviation image features were significantly associated with semantic radiological features.

  19. Illumination Profile & Dispersion Variation Effects on Radial Velocity Measurements

    Science.gov (United States)

    Grieves, Nolan; Ge, Jian; Thomas, Neil B.; Ma, Bo; Li, Rui; SDSS-III

    2015-01-01

    The Multi-object APO Radial-Velocity Exoplanet Large-Area Survey (MARVELS) measures radial velocities using a fiber-fed dispersed fixed-delay interferometer (DFDI) with a moderate dispersion spectrograph. This setup allows a unique insight into the 2D illumination profile from the fiber on to the dispersion grating. Illumination profile investigations show large changes in the profile over time and fiber location. These profile changes are correlated with dispersion changes and long-term radial velocity offsets, a major problem within the MARVELS radial velocity data. Characterizing illumination profiles creates a method to both detect and correct radial velocity offsets, allowing for better planet detection. Here we report our early results from this study including improvement of radial velocity data points from detected giant planet candidates. We also report an illumination profile experiment conducted at the Kitt Peak National Observatory using the EXPERT instrument, which has a DFDI mode similar to MARVELS. Using profile controlling octagonal-shaped fibers, long term offsets over a 3 month time period were reduced from ~50 m/s to within the photon limit of ~4 m/s.

  20. Electronic orbital angular momentum and magnetism of graphene

    Energy Technology Data Exchange (ETDEWEB)

    Luo, Ji, E-mail: ji.luo@upr.edu

    2014-10-01

    Orbital angular momentum (OAM) of graphene electrons in a perpendicular magnetic field is calculated and corresponding magnetic moment is used to investigate the magnetism of perfect graphene. Variation in magnetization demonstrates its decrease with carrier-doping, plateaus in a large field, and de Haas–van Alphen oscillation. Regulation of graphene's magnetism by a parallel electric field is presented. The OAM originates from atomic-scale electronic motion in graphene lattice, and vector hopping interaction between carbon atomic orbitals is the building element. A comparison between OAM of graphene electrons, OAM of Dirac fermions, and total angular momentum of the latter demonstrates their different roles in graphene's magnetism. Applicability and relation to experiments of the results are discussed. - Highlights: • Orbital angular momentum of graphene electrons is calculated. • Orbital magnetic moment of graphene electrons is obtained. • Variation in magnetization of graphene is calculated. • Roles of different kinds of angular momentum are investigated.

  1. Angular momentum in QGP holography

    Directory of Open Access Journals (Sweden)

    Brett McInnes

    2014-10-01

    Full Text Available The quark chemical potential is one of the fundamental parameters describing the quark–gluon plasma produced by sufficiently energetic heavy-ion collisions. It is not large at the extremely high temperatures probed by the LHC, but it plays a key role in discussions of the beam energy scan programmes at the RHIC and other facilities. On the other hand, collisions at such energies typically (that is, in peripheral collisions give rise to very high values of the angular momentum density. Here we explain that holographic estimates of the quark chemical potential of a rotating sample of plasma can be very considerably improved by taking the angular momentum into account.

  2. Large-uncertainty intelligent states for angular momentum and angle

    International Nuclear Information System (INIS)

    Goette, Joerg B; Zambrini, Roberta; Franke-Arnold, Sonja; Barnett, Stephen M

    2005-01-01

    The equality in the uncertainty principle for linear momentum and position is obtained for states which also minimize the uncertainty product. However, in the uncertainty relation for angular momentum and angular position both sides of the inequality are state dependent and therefore the intelligent states, which satisfy the equality, do not necessarily give a minimum for the uncertainty product. In this paper, we highlight the difference between intelligent states and minimum uncertainty states by investigating a class of intelligent states which obey the equality in the angular uncertainty relation while having an arbitrarily large uncertainty product. To develop an understanding for the uncertainties of angle and angular momentum for the large-uncertainty intelligent states we compare exact solutions with analytical approximations in two limiting cases

  3. Radial transfer effects for poloidal rotation

    Science.gov (United States)

    Hallatschek, Klaus

    2010-11-01

    Radial transfer of energy or momentum is the principal agent responsible for radial structures of Geodesic Acoustic Modes (GAMs) or stationary Zonal Flows (ZF) generated by the turbulence. For the GAM, following a physical approach, it is possible to find useful expressions for the individual components of the Poynting flux or radial group velocity allowing predictions where a mathematical full analysis is unfeasible. Striking differences between up-down symmetric flux surfaces and asymmetric ones have been found. For divertor geometries, e.g., the direction of the propagation depends on the sign of the ion grad-B drift with respect to the X-point, reminiscent of a sensitive determinant of the H-mode threshold. In nonlocal turbulence computations it becomes obvious that the linear energy transfer terms can be completely overwhelmed by the action of the turbulence. In contrast, stationary ZFs are governed by the turbulent radial transfer of momentum. For sufficiently large systems, the Reynolds stress becomes a deterministic functional of the flows, which can be empirically determined from the stress response in computational turbulence studies. The functional allows predictions even on flow/turbulence states not readily obtainable from small amplitude noise, such as certain transport bifurcations or meta-stable states.

  4. Power calculation of linear and angular incremental encoders

    Science.gov (United States)

    Prokofev, Aleksandr V.; Timofeev, Aleksandr N.; Mednikov, Sergey V.; Sycheva, Elena A.

    2016-04-01

    Automation technology is constantly expanding its role in improving the efficiency of manufacturing and testing processes in all branches of industry. More than ever before, the mechanical movements of linear slides, rotary tables, robot arms, actuators, etc. are numerically controlled. Linear and angular incremental photoelectric encoders measure mechanical motion and transmit the measured values back to the control unit. The capabilities of these systems are undergoing continual development in terms of their resolution, accuracy and reliability, their measuring ranges, and maximum speeds. This article discusses the method of power calculation of linear and angular incremental photoelectric encoders, to find the optimum parameters for its components, such as light emitters, photo-detectors, linear and angular scales, optical components etc. It analyzes methods and devices that permit high resolutions in the order of 0.001 mm or 0.001°, as well as large measuring lengths of over 100 mm. In linear and angular incremental photoelectric encoders optical beam is usually formulated by a condenser lens passes through the measuring unit changes its value depending on the movement of a scanning head or measuring raster. Past light beam is converting into an electrical signal by the photo-detecter's block for processing in the electrical block. Therefore, for calculating the energy source is a value of the desired value of the optical signal at the input of the photo-detecter's block, which reliably recorded and processed in the electronic unit of linear and angular incremental optoelectronic encoders. Automation technology is constantly expanding its role in improving the efficiency of manufacturing and testing processes in all branches of industry. More than ever before, the mechanical movements of linear slides, rotary tables, robot arms, actuators, etc. are numerically controlled. Linear and angular incremental photoelectric encoders measure mechanical motion and

  5. Angular analysis of $\\Lambda_{b} \\rightarrow \\Lambda \\mu^{+}\\mu^{-}$

    CERN Multimedia

    Chatzikonstantinidis, Georgios

    2018-01-01

    The angular analysis of the rare baryon decay of $\\Lambda_{b}\\rightarrow \\Lambda (\\rightarrow p\\pi^{-})\\mu^{+}\\mu^{-}$ in high $q^{2}$ is presented. The dataset that is used corresponds to an integrated luminosity of 5.0 fb$^{-1}$ of pp - collision data collected at centre-of-mass energies between 7 and 13 TeV by the LHCb detector in 2011, 2012, 2015 and 2016. Angular observables are determined using a moment analysis of the angular distribution.

  6. Angular momentum of circularly polarized light in dielectric media

    OpenAIRE

    Mansuripur, Masud

    2014-01-01

    A circularly polarized plane-wave is known to have no angular momentum when examined through Maxwell's equations. This, however, contradicts the experimentally observed facts, where finite segments of plane waves are known to be capable of imparting angular momentum to birefringent platelets. Using a superposition of four plane-waves propagating at slightly different angles to a common direction, we derive an expression for the angular momentum density of a single plane-wave in the limit when...

  7. Anterior transposition of the radial nerve--a cadaveric study.

    Science.gov (United States)

    Yakkanti, Madhusudhan R; Roberts, Craig S; Murphy, Joshua; Acland, Robert D

    2008-01-01

    The radial nerve is at risk during the posterior plating of the humerus. The purpose of this anatomic study was to assess the extent of radial nerve dissection required for anterior transposition through the fracture site (transfracture anterior transposition). A cadaver study was conducted approaching the humerus by a posterior midline incision. The extent of dissection of the nerve necessary for plate fixation of the humerus fracture was measured. An osteotomy was created to model a humeral shaft fracture at the spiral groove (OTA classification 12-A2, 12-A3). The radial nerve was then transposed anterior to the humeral shaft through the fracture site. The additional dissection of the radial nerve and the extent of release of soft tissue from the humerus shaft to achieve the transposition were measured. Plating required a dissection of the radial nerve 1.78 cm proximal and 2.13 cm distal to the spiral groove. Transfracture anterior transposition of the radial nerve required an average dissection of 2.24 cm proximal and 2.68 cm distal to the spiral groove. The lateral intermuscular septum had to be released for 2.21 cm on the distal fragment to maintain laxity of the transposed nerve. Transfracture anterior transposition of the radial nerve before plating is feasible with dissection proximal and distal to the spiral groove and elevation of the lateral intermuscular septum. Potential clinical advantages of this technique include enhanced fracture site visualization, application of broader plates, and protection of the radial nerve during the internal fixation.

  8. MR imaging in chronic rupture of the ulnar collateral ligament of the thumb

    International Nuclear Information System (INIS)

    Lohman, M.; Kivisaari, A.; Kivisaari, L.; Vasenius, J.

    2000-01-01

    MR imaging has been shown as the best radiologic method for verifying and classifying acute ulnar collateral ligament (UCL) ruptures of the thumb. Our aim was to analyse the usefulness of MR also in old ruptures and to establish the most useful sequences. Ten patients with an old UCL rupture of the thumb were preoperatively imaged using 1.5 T MR. Three radiologists blinded to the findings separately analysed the MR images of these patients and of 10 age-and sex-matched voluntary controls. MR findings of the patients were compared with those of surgery. The consensus diagnosis of an UCL rupture was accurate in all 10 patients. All controls were classified as having no UCL rupture. In 5 of the 7 patients with a surgically defined Stener or non-Stener lesion, the consensus diagnosis was the same as the operative diagnosis. Due to excessive scarring it was not possible to verify any Stener lesion intra-operatively in 3 patients. The most informative MR sequence was T2 TSE in the coronal plane, the second most informative was T1 SE with fat suppression in the coronal plane. An old UCL rupture is well verified by MR but typing of the lesion as either a Stener or non-Stener type is not always possible

  9. Can Physical Examination Create a Stener Lesion?

    Science.gov (United States)

    Lankachandra, Manesha; Eggers, John P; Bogener, James W; Hutchison, Richard L

    2017-09-01

    The purpose of this study is to determine whether a Stener lesion can be created while testing stability of the ulnar collateral ligament (UCL) of the thumb. Testing was performed in a manner that reproduced clinical examination. Six fresh frozen hand and forearm specimens underwent sequential sectioning of the accessory UCL, the proper UCL, and the ulnar sagittal band. Measurements of radial deviation of the metacarpophalangeal (MCP) joint were taken with the thumb in neutral rotation, pronation and supination, both with 0 degrees and with 30 degrees of flexion of the MCP joint. Visual examination was performed to assess the presence of a Stener lesion. No Stener lesion was created in any position as long as the fascial origin of the ulnar sagittal band at the adductor pollicis longus remained intact. After creating a defect in the ulnar sagittal band, a Stener lesion was created in two specimens, but only when the thumb was flexed and supinated. Pronation provided more stability, and supination provided less stability, with one or both components cut, especially when testing at 30° of flexion. Compared to both components cut without flexion or rotation, there was a statistically significant difference in angulation with the 30 degrees of MCP joint flexion in both neutral rotation in supination. Performing a physical examination to assess the amount of instability of an ulnar collateral ligament injury did not create a Stener lesion if the exam was performed in a controlled, gentle manner with the thumb held without rotation. If the thumb is held in neutral rotation during the exam, an iatrogenic Stener lesion should not be created.

  10. A New Filtering Algorithm Utilizing Radial Velocity Measurement

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-feng; DU Zi-cheng; PAN Quan

    2005-01-01

    Pulse Doppler radar measurements consist of range, azimuth, elevation and radial velocity. Most of the radar tracking algorithms in engineering only utilize position measurement. The extended Kalman filter with radial velocity measureneut is presented, then a new filtering algorithm utilizing radial velocity measurement is proposed to improve tracking results and the theoretical analysis is also given. Simulation results of the new algorithm, converted measurement Kalman filter, extended Kalman filter are compared. The effectiveness of the new algorithm is verified by simulation results.

  11. Photoelectric Radial Velocities, Paper XIX Additional Spectroscopic ...

    Indian Academy of Sciences (India)

    ian velocity curve that does justice to the measurements, but it cannot be expected to have much predictive power. Key words. Stars: late-type—stars: radial velocities—spectroscopic binaries—orbits. 0. Preamble. The 'Redman K stars' are a lot of seventh-magnitude K stars whose radial velocities were first observed by ...

  12. Angular momentum of circularly polarized light in dielectric media

    Science.gov (United States)

    Mansuripur, Masud

    2005-07-01

    A circularly polarized plane-wave is known to have no angular momentum when examined through Maxwell’s equations. This, however, contradicts the experimentally observed facts, where finite segments of plane waves are known to be capable of imparting angular momentum to birefringent platelets. Using a superposition of four plane-waves propagating at slightly different angles to a common direction, we derive an expression for the angular momentum density of a single plane-wave in the limit when the propagation directions of the four beams come into alignment. We proceed to use this four-beam technique to analyze the conservation of angular momentum when a plane-wave enters a dielectric slab from the free space. The angular momentum of the beam is shown to decrease upon entering the dielectric medium, by virtue of the fact that the incident beam exerts a torque on the slab surface at the point of entry. When the beam leaves the slab, it imparts an equal but opposite torque to the exit facet, thus recovering its initial angular momentum upon re-emerging into the free-space. Along the way, we derive an expression for the outward-directed force of a normally incident, finite-diameter beam on a dielectric surface; the possible relationship between this force and the experimentally observed bulging of a liquid surface under intense illumination is explored.

  13. Angular momentum conservation law in light-front quantum field theory

    Energy Technology Data Exchange (ETDEWEB)

    Chiu, Kelly Yu-Ju; Brodsky, Stanley J.; /SLAC /Stanford U.

    2017-03-01

    We prove the Lorentz invariance of the angular momentum conservation law and the helicity sum rule for relativistic composite systems in the light-front formulation. We explicitly show that j 3 , the z -component of the angular momentum remains unchanged under Lorentz transformations generated by the light-front kinematical boost operators. The invariance of j 3 under Lorentz transformations is a feature unique to the front form. Applying the Lorentz invariance of the angular quantum number in the front form, we obtain a selection rule for the orbital angular momentum which can be used to eliminate certain interaction vertices in QED and QCD. We also generalize the selection rule to any renormalizable theory and show that there exists an upper bound on the change of orbital angular momentum in scattering processes at any fixed order in perturbation theory.

  14. Linear theory radial and nonradial pulsations of DA dwarf stars

    International Nuclear Information System (INIS)

    Starrfield, S.; Cox, A.N.; Hodson, S.; Pesnell, W.D.

    1982-01-01

    The Los Alamos stellar envelope and radial linear non-adiabatic computer code, along with a new Los Alamos non-radial code are used to investigate the total hydrogen mass necessary to produce the non-radial instability of DA dwarfs

  15. Sorting and quantifying orbital angular momentum of laser beams

    CSIR Research Space (South Africa)

    Schulze, C

    2013-10-01

    Full Text Available We present a novel tool for sorting the orbital angular momentum and to determine the orbital angular momentum density of laser beams, which is based on the use of correlation filters....

  16. Guyon's canal syndrome due to tortuous ulnar artery with DeQuervain stenosing tenosynovitis, ligamentous injuries and dorsal intercalated segmental instability syndrome, a rare presentation: a case report

    OpenAIRE

    Zeeshan, Muhammad; Ahmed, Farhan; Kanwal, Darakhshan; Khalid, Qazi Saad Bin; Ahmed, Muhammad Nadeem

    2009-01-01

    The Guyon's canal syndrome is a well known clinical entity and may have significant impact on patient's quality of life. We report a case of 43-year-old male who presented with complaints of pain and numbness in right hand and difficulty in writing for past one month. On imaging diagnosis of Guyon's canal syndrome because of tortuous ulnar artery was made with additional findings of DeQuervain's stenosing tenosynovitis and dorsal intercalated segmental instability syndrome with ligamentous in...

  17. The mass and angular momentum of reconstructed metric perturbations

    Science.gov (United States)

    van de Meent, Maarten

    2017-06-01

    We prove a key result regarding the mass and angular momentum content of linear vacuum perturbations of the Kerr metric obtained through the formalism developed by Chrzarnowski, Cohen, and Kegeles (CCK). More precisely, we prove that the Abbott-Deser mass and angular momentum integrals of any such perturbation vanish when that perturbation was obtained from a regular Fourier mode of the Hertz potential. As a corollary we obtain a generalization of previous results on the completion of the ‘no string’ radiation gauge metric perturbation generated by a point particle. We find that for any bound orbit around a Kerr black hole, the mass and angular momentum perturbations completing the CCK metric are simply the energy and angular momentum of the particle ‘outside’ the orbit and vanish ‘inside’ the orbit.

  18. Thrombosis of digital arteries associated with tamoxifen use: case report.

    Science.gov (United States)

    Hutchison, Richard L; Rayan, Ghazi M

    2012-02-01

    Arterial thrombosis in the upper extremity occurs often at the wrist. We report a unique case of thrombosis that involved multiple digital arteries, without radial or ulnar artery involvement, which developed only after using tamoxifen despite chronic occupational blunt percussive hand use. Revascularization was achieved after thrombectomy. Multiple digital arterial thromboses may complicate the use of tamoxifen. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. High Angular Momentum Rydberg Wave Packets

    Science.gov (United States)

    Wyker, Brendan

    2011-12-01

    High angular momentum Rydberg wave packets are studied. Application of carefully tailored electric fields to low angular momentum, high- n (n ˜ 300) Rydberg atoms creates coherent superpositions of Stark states with near extreme values of angular momentum, ℓ. Wave packet components orbit the parent nucleus at rates that depend on their energy, leading to periods of localization and delocalization as the components come into and go out of phase with each other. Monitoring survival probability signals in the presence of position dependent probing leads to observation of characteristic oscillations based on the composition of the wave packet. The discrete nature of electron energy levels is observed through the measurement of quantum revivals in the wave packet localization signal. Time-domain spectroscopy of these signals allows determination of both the population and phase of individual superposition components. Precise manipulation of wave packets is achieved through further application of pulsed electric fields. Decoherence effects due to background gas collisions and electrical noise are also detailed. Quantized classical trajectory Monte-Carlo simulations are introduced and agree remarkably well with experimental results.

  20. The Angular Momentum of Baryons and Dark Matter Halos Revisited

    Science.gov (United States)

    Kimm, Taysun; Devriendt, Julien; Slyz, Adrianne; Pichon, Christophe; Kassin, Susan A.; Dubois, Yohan

    2011-01-01

    Recent theoretical studies have shown that galaxies at high redshift are fed by cold, dense gas filaments, suggesting angular momentum transport by gas differs from that by dark matter. Revisiting this issue using high-resolution cosmological hydrodynamics simulations with adaptive-mesh refinement (AMR), we find that at the time of accretion, gas and dark matter do carry a similar amount of specific angular momentum, but that it is systematically higher than that of the dark matter halo as a whole. At high redshift, freshly accreted gas rapidly streams into the central region of the halo, directly depositing this large amount of angular momentum within a sphere of radius r = 0.1R(sub vir). In contrast, dark matter particles pass through the central region unscathed, and a fraction of them ends up populating the outer regions of the halo (r/R(sub vir) > 0.1), redistributing angular momentum in the process. As a result, large-scale motions of the cosmic web have to be considered as the origin of gas angular momentum rather than its virialised dark matter halo host. This generic result holds for halos of all masses at all redshifts, as radiative cooling ensures that a significant fraction of baryons remain trapped at the centre of the halos. Despite this injection of angular momentum enriched gas, we predict an amount for stellar discs which is in fair agreement with observations at z=0. This arises because the total specific angular momentum of the baryons (gas and stars) remains close to that of dark matter halos. Indeed, our simulations indicate that any differential loss of angular momentum amplitude between the two components is minor even though dark matter halos continuously lose between half and two-thirds of their specific angular momentum modulus as they evolve. In light of our results, a substantial revision of the standard theory of disc formation seems to be required. We propose a new scenario where gas efficiently carries the angular momentum generated

  1. Effect of the radial electric field on turbulence

    International Nuclear Information System (INIS)

    Carreras, B.A.; Lynch, V.E.

    1990-01-01

    For many years, the neoclassical transport theory for three- dimensional magnetic configurations, such as magnetic mirrors, ELMO Bumpy Tori (EBTs), and stellarators, has recognized the critical role of the radial electric field in the confinement. It was in these confinement devices that the first experimental measurements of the radial electric field were made and correlated with confinement losses. In tokamaks, the axisymmetry implies that the neoclassical fluxes are ambipolar and, as a consequence, independent of the radial electric field. However, axisymmetry is not strict in a tokamak with turbulent fluctuations, and near the limiter ambipolarity clearly breaks down. Therefore, the question of the effect of the radial electric field on tokamak confinement has been raised in recent years. In particular, the radial electric field has been proposed to explain the transition from L-mode to H-mode confinement. There is some initial experimental evidence supporting this type of explanation, although there is not yet a self-consistent theory explaining the generation of the electric field and its effect on the transport. Here, a brief review of recent results is presented. 27 refs., 4 figs

  2. A user's evaluation of radial flow HEPA filters

    International Nuclear Information System (INIS)

    Purcell, J.A.

    1992-07-01

    High efficiency particulate air (HEPA) filters of rectangular cross section have been used to remove particulates and the associated radioactivity from air ventilation streams since the advent of nuclear materials processing. Use of round axial flow HEPA filters is also longstanding. The advantages of radial flow filters in a circular configuration have been well demonstrated in UKAEA during the last 5--7 years. An evaluation of radial flow filters for fissile process gloveboxes reveals several substantial benefits in addition to the advantages claimed in UKAEA Facilities. The radial flow filter may be provided in a favorable geometry resulting in improved criticality safety. The filter configuration lends to in-place testing at the glovebox to exhaust duct interface. This will achieve compliance with DOE Order 6430.1A, Section 99.0.2. Preliminary testing at SRS for radial flow filters manufactured by Flanders Filters, Inc. revealed compliance in all the usual specifications for filtration efficiency, pressure differential and materials of construction. An evaluation, further detailed in this report, indicates that the radial flow HEPA filter should be considered for inclusion in new ventilation system designs

  3. Radial extension of drift waves in presence of velocity profiles

    International Nuclear Information System (INIS)

    Sen, S.; Weiland, J.

    1994-01-01

    The effect of a radially varying poloidal velocity field on the recently found radially extended toroidal drift waves is investigated analytically. The role of velocity curvature (υ φ '') is found to have robust effects on the radial model structure of the mode. For a positive value of the curvature (Usually found in the H-mode edges) the radial model envelope, similar to the sheared slab case, becomes fully outgoing. The mode is therefore stable. On the other hand, for a negative value of the curvature (usually observed in the L-mode edges) all the characteristics of conventional drift waves return back. The radial mode envelope reduces to a localized Gaussian shape and the mode is therefore unstable again for typical (magnetic) shear values in tokamaks. Velocity shear (υ φ ??) on the other hand is found to have rather insignificant role both in determining the radial model structure and stability

  4. A systematic construction of microstate geometries with low angular momentum

    Science.gov (United States)

    Bena, Iosif; Heidmann, Pierre; Ramírez, Pedro F.

    2017-10-01

    We outline a systematic procedure to obtain horizonless microstate geometries that have the same charges as three-charge five-dimensional black holes with a macroscopically-large horizon area and an arbitrarily-small angular momentum. There are two routes through which such solutions can be constructed: using multi-center Gibbons-Hawking (GH) spaces or using superstratum technology. So far the only solutions corre-sponding to microstate geometries for black holes with no angular momentum have been obtained via superstrata [1], and multi-center Gibbons-Hawking spaces have been believed to give rise only to microstate geometries of BMPV black holes with a large angular mo-mentum [2]. We perform a thorough search throughout the parameter space of smooth horizonless solutions with four GH centers and find that these have an angular momentum that is generally larger than 80% of the cosmic censorship bound. However, we find that solutions with three GH centers and one supertube (which are smooth in six-dimensional supergravity) can have an arbitrarily-low angular momentum. Our construction thus gives a recipe to build large classes of microstate geometries for zero-angular-momentum black holes without resorting to superstratum technology.

  5. Effect of nutritional intake towards Angular cheilitis of orphanage children

    Directory of Open Access Journals (Sweden)

    Nurdiani Rakhmayanthie

    2016-11-01

    Full Text Available Introduction: Angular cheilitis is one of the oral manifestations of iron, vitamin B12, and folate deficiency. This manifestation frequently seen in people at first and second decade. The purpose of this study was to obtain the prevalence of angular cheilitis and its classifications related to the nutritional intake level in 6-18 years old children. Methods: This research was a descriptive study with 53 children between 6-18 years old from Muhammadiyah Orphanage Bandung as the samples. The oral cavity was examined clinically and their food consumption in a week was noted in Food Recall 24 hours and Food Frequency Questionnaire (FFQ in order to measure their nutritional intake level. Results: There are 23 children with angular cheilitis. 13% has iron and folate deficiencies, and 87% has iron, vitamin B12, and folate deficiencies. Angular cheilitis types that has been found are Type I (39%, Type II (48% and Type III (13%. Conclusion: The prevalence of angular cheilitis in 6-18 years old children in Muhammadiyah Orphanage Bandung was moderately high, most of them were having iron, vitamin B12, and folate deficiencies. Type II angular cheilitis was the most frequently seen.

  6. Combined Radial and Femoral Access Strategy and Radial-Femoral Rendezvous in Patients With Long and Complex Iliac Occlusions.

    Science.gov (United States)

    Hanna, Elias B; Mogabgab, Owen N; Baydoun, Hassan

    2018-01-01

    We present cases of complex, calcified iliac occlusive disease revascularized via a combined radial-femoral access strategy. Through a 6-French, 125-cm transradial guiding catheter, antegrade guidewires and catheters are advanced into the iliac occlusion, while retrograde devices are advanced transfemorally. The transradial and transfemoral channels communicate, allowing the devices to cross the occlusion into the true lumen (radial-femoral antegrade-retrograde rendezvous).

  7. Reliability and precision of stress sonography of the ulnar collateral ligament.

    Science.gov (United States)

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  8. Learning web development with Bootstrap and AngularJS

    CERN Document Server

    Radford, Stephen

    2015-01-01

    Whether you know a little about Bootstrap or AngularJS, or you're a complete beginner, this book will enhance your capabilities in both frameworks and you'll build a fully functional web app. A working knowledge of HTML, CSS, and JavaScript is required to fully get to grips with Bootstrap and AngularJS.

  9. Rotational speedups accompanying angular deceleration of a superfluid

    International Nuclear Information System (INIS)

    Campbell, L.J.

    1979-01-01

    Exact calculations of the angular deceleration of superfluid vortex arrays show momentary speedups in the angular velocity caused by coherent, multiple vortex loss at the boundary. The existence and shape of the speedups depend on the vortex friction, the deceleration rate, and the pattern symmetry. The phenomenon resembles, in several ways, that observed in pulsars

  10. Angular momentum transport with twisted exciton wave packets

    Science.gov (United States)

    Zang, Xiaoning; Lusk, Mark T.

    2017-10-01

    A chain of cofacial molecules with CN or CN h symmetry supports excitonic states with a screwlike structure. These can be quantified with the combination of an axial wave number and an azimuthal winding number. Combinations of these states can be used to construct excitonic wave packets that spiral down the chain with well-determined linear and angular momenta. These twisted exciton wave packets can be created and annihilated using laser pulses, and their angular momentum can be optically modified during transit. This allows for the creation of optoexcitonic circuits in which information, encoded in the angular momentum of light, is converted into excitonic wave packets that can be manipulated, transported, and then reemitted. A tight-binding paradigm is used to demonstrate the key ideas. The approach is then extended to quantify the evolution of twisted exciton wave packets in a many-body, multilevel time-domain density functional theory setting. In both settings, numerical methods are developed that allow the site-to-site transfer of angular momentum to be quantified.

  11. Total angular momentum from Dirac eigenspinors

    International Nuclear Information System (INIS)

    Szabados, Laszlo B

    2008-01-01

    The eigenvalue problem for Dirac operators, constructed from two connections on the spinor bundle over closed spacelike 2-surfaces, is investigated. A class of divergence-free vector fields, built from the eigenspinors, are found, which, for the lowest eigenvalue, reproduce the rotation Killing vectors of metric spheres, and provide rotation BMS vector fields at future null infinity. This makes it possible to introduce a well-defined, gauge invariant spatial angular momentum at null infinity, which reduces to the standard expression in stationary spacetimes. The general formula for the angular momentum flux carried away by the gravitational radiation is also derived

  12. A novel structure of permanent-magnet-biased radial hybrid magnetic bearing

    International Nuclear Information System (INIS)

    Sun Jinji; Fang Jiancheng

    2011-01-01

    The paper proposes a novel structure for a permanent-magnet-biased radial hybrid magnetic bearing. Based on the air gap between the rotor and stator of traditional radial hybrid magnetic bearings, a subsidiary air gap is first constructed between the permanent magnets and the inner magnetic parts. Radial magnetic bearing makes X and Y magnetic fields independent of each other with separate stator poles, and the subsidiary air gap makes control flux to a close loop. As a result, magnetic field coupling of the X and Y channels is decreased significantly by the radial hybrid magnetic bearing and makes it easier to design control systems. Then an external rotor structure is designed into the radial hybrid magnetic bearing. The working principle of the radial hybrid magnetic bearing and its mathematical model is discussed. Finally, a non-linear magnetic network method is proposed to analyze the radial hybrid magnetic bearing. Simulation results indicate that magnetic fields in the two channels of the proposed radial hybrid magnetic bearing decouple well from each other.

  13. A novel structure of permanent-magnet-biased radial hybrid magnetic bearing

    Energy Technology Data Exchange (ETDEWEB)

    Sun Jinji, E-mail: sunjinji@aspe.buaa.edu.c [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, 100191 (China); Fang Jiancheng [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, 100191 (China)

    2011-01-15

    The paper proposes a novel structure for a permanent-magnet-biased radial hybrid magnetic bearing. Based on the air gap between the rotor and stator of traditional radial hybrid magnetic bearings, a subsidiary air gap is first constructed between the permanent magnets and the inner magnetic parts. Radial magnetic bearing makes X and Y magnetic fields independent of each other with separate stator poles, and the subsidiary air gap makes control flux to a close loop. As a result, magnetic field coupling of the X and Y channels is decreased significantly by the radial hybrid magnetic bearing and makes it easier to design control systems. Then an external rotor structure is designed into the radial hybrid magnetic bearing. The working principle of the radial hybrid magnetic bearing and its mathematical model is discussed. Finally, a non-linear magnetic network method is proposed to analyze the radial hybrid magnetic bearing. Simulation results indicate that magnetic fields in the two channels of the proposed radial hybrid magnetic bearing decouple well from each other.

  14. Detonation in supersonic radial outflow

    KAUST Repository

    Kasimov, Aslan R.

    2014-11-07

    We report on the structure and dynamics of gaseous detonation stabilized in a supersonic flow emanating radially from a central source. The steady-state solutions are computed and their range of existence is investigated. Two-dimensional simulations are carried out in order to explore the stability of the steady-state solutions. It is found that both collapsing and expanding two-dimensional cellular detonations exist. The latter can be stabilized by putting several rigid obstacles in the flow downstream of the steady-state sonic locus. The problem of initiation of standing detonation stabilized in the radial flow is also investigated numerically. © 2014 Cambridge University Press.

  15. On the Angular Momentum Loss of Tropical Cyclones: An f-Plane Approximation

    Science.gov (United States)

    Kang, Hyun-Gyu; Cheong, Hyeong-Bin; Kim, Won-Ho

    2018-02-01

    The angular momentum for ideal axisymmetric tropical cyclones on the f-plane is investigated with a focus on the total-volume integrated quantity. Budget analysis of the momentum equation at cylindrical coordinates shows that a tropical cyclone loses angular momentum during its development and mature stages due to the dynamical difference between the viscous inward-flow near the surface and the angular momentum conserving outward-flow aloft. The total relative angular momentum of a tropical cyclone, as a result, can be negative (i.e., implying anticyclonic rotation as a whole) despite intense cyclonic wind in the tropospheric layers. This anticyclonic rotation was measured in terms of the super-rotation ratio, the ratio of total relative angular momentum to the planetary angular momentum. Simulations with the numerical model of Weather Research and Forecasting (WRF) version 3.4.1 was found to be in favor of the theoretical angular-momentum budget analysis. It was revealed in the numerical simulations that the super-rotation ratio was negative, indicating a sub-rotation, as was predicted by analysis. The sub-rotation ratio was found to be less than one percent for typical tropical cyclones. To show the angular momentum decrease even in the decaying stage, numerical simulations where the thermal forcing by sea surface temperature switched off in the mature stage were carried out. In support of the angular momentum budget analysis, the results indicated that the angular momentum also decreases for a while soon after the forcing was eliminated.

  16. Radial nerve dysfunction (image)

    Science.gov (United States)

    The radial nerve travels down the arm and supplies movement to the triceps muscle at the back of the upper arm. ... the wrist and hand. The usual causes of nerve dysfunction are direct trauma, prolonged pressure on the ...

  17. Variable stator radial turbine

    Science.gov (United States)

    Rogo, C.; Hajek, T.; Chen, A. G.

    1984-01-01

    A radial turbine stage with a variable area nozzle was investigated. A high work capacity turbine design with a known high performance base was modified to accept a fixed vane stagger angle moveable sidewall nozzle. The nozzle area was varied by moving the forward and rearward sidewalls. Diffusing and accelerating rotor inlet ramps were evaluated in combinations with hub and shroud rotor exit rings. Performance of contoured sidewalls and the location of the sidewall split line with respect to the rotor inlet was compared to the baseline. Performance and rotor exit survey data are presented for 31 different geometries. Detail survey data at the nozzle exit are given in contour plot format for five configurations. A data base is provided for a variable geometry concept that is a viable alternative to the more common pivoted vane variable geometry radial turbine.

  18. Lidar Orbital Angular Momentum Sensor

    Data.gov (United States)

    National Aeronautics and Space Administration — The recognition in recent decades that electromagnetic fields have angular momentum (AM) in the form of not only polarization (or spin AM) but also orbital (OAM) has...

  19. Schmidt decomposition for non-collinear biphoton angular wave functions

    International Nuclear Information System (INIS)

    Fedorov, M V

    2015-01-01

    Schmidt modes of non-collinear biphoton angular wave functions are found analytically. The experimentally realizable procedure for their separation is described. Parameters of the Schmidt decomposition are used to evaluate the degree of the biphoton's angular entanglement. (paper)

  20. Modeling of the angular dependence of plasma etching

    International Nuclear Information System (INIS)

    Guo Wei; Sawin, Herbert H.

    2009-01-01

    An understanding of the angular dependence of etching yield is essential to investigate the origins of sidewall roughness during plasma etching. In this article the angular dependence of polysilicon etching in Cl 2 plasma was modeled as a combination of individual angular-dependent etching yields for ion-initiated processes including physical sputtering, ion-induced etching, vacancy generation, and removal. The modeled etching yield exhibited a maximum at ∼60 degree sign off-normal ion angle at low flux ratio, indicative of physical sputtering. It transformed to the angular dependence of ion-induced etching with the increase in the neutral-to-ion flux ratio. Good agreement between the modeling and the experiments was achieved for various flux ratios and ion energies. The variation of etching yield in response to the ion angle was incorporated in the three-dimensional profile simulation and qualitative agreement was obtained. The surface composition was calculated and compared to x-ray photoelectron spectroscopy (XPS) analysis. The modeling indicated a Cl areal density of 3x10 15 atoms/cm 2 on the surface that is close to the value determined by the XPS analysis. The response of Cl fraction to ion energy and flux ratio was modeled and correlated with the etching yields. The complete mixing-layer kinetics model with the angular dependence effect will be used for quantitative surface roughening analysis using a profile simulator in future work.