WorldWideScience

Sample records for radial artery transradial

  1. Radial artery spasm occurred in transradial coronary intervention for coronary heart disease: its occurrence and predictors

    International Nuclear Information System (INIS)

    Zhong Jiming; Li Lang; Lu Yongguang; Zeng Shuyi

    2011-01-01

    Objective: To discuss the incidence and clinical predictors of radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease. Methods: A total of 1020 patients, who underwent transradial coronary procedures for coronary heart disease during the period of May 2007 Jan 2010 in authors' hospital, were enrolled in this study. All clinical information and medication were recorded in detail. Arteriography via radial artery was performed in all patients. The diameter of the radial artery as well as the arterial anatomy, including arterial variations, were determined and observed, which was follow by coronary angiography or percutaneous coronary intervention. Multivariate Logistic regression analysis was adopted to evaluate the variables, such as clinical parameters, angiographic characteristics of the radial artery and procedure-related factors, in predicting the occurrence of radial artery spasm. Results: Radial artery spasm occurred in 209 (20.5%) patients. Multivariate Logistic regression analysis showed that the following eight factors were independently associated with the occurrence of radial artery spasm. These factors were as follows: female gender (OR=2.8, 95% CI 2.5-5.8; P=0.001), age (OR=0.68, 95% CI 0.60-0.92; P=0.003), smoking (OR=2.3, 95% CI 1.8-4.1; P=0.026), moderate-to-severe pain of forearm during radial artery cannulation (OR=3.0, 95% CI 2.3-4.8; P=0.006), radial artery anatomical abnormalities (OR=4.7, 95% CI 3.6-7.2; P=0.002), the ratio of radial artery diameter to patient's height (RAH) (OR=5.2, 95% CI 3.7-8.1; P=0.012), the ratio of radial artery diameter to outer diameter of the sheath (RAOD) (OR=5.8, 95% CI 4.2-6.9; P=0.006) and the number of catheter exchange (OR=2.3, 95% CI 1.4-4.3; P=0.038). Conclusion: Radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease is frequently seen in clinical practice. Female gender, younger age, smoking, forearm pain during

  2. The effect of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures: a systematic review.

    Science.gov (United States)

    Curtis, Elizabeth; Fernandez, Ritin; Lee, Astin

    2017-07-01

    The uptake of percutaneous coronary procedures via the radial artery has increased internationally due to the decreased risk of complications and increased patient satisfaction. The increased susceptibility of the radial artery to spasm however presents a potential risk for procedural failure. Although most experts agree on the need for prophylactic medications to reduce radial artery spasm, currently there is inconsistency in literature regarding the most effective vasodilatory medication or combination of medications. The objective of this study is to identify the effectiveness of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures. This review considered studies that included participants aged 18 years and over undergoing non-emergent transradial percutaneous coronary artery procedures. This review considered studies that used vasodilating intravenous and intra-arterial medications or combinations of medications prior to commencing and during transradial coronary approaches to reduce radial artery spasm. The outcomes of interest were the incidence of radial artery spasm during percutaneous coronary procedure using objective and/or subjective measures and its effect on the successful completion of the procedure. Randomized controlled trials published in the English language between 1989 to date were considered for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. An initial search of MEDLINE, CINAHL and Scopus was undertaken, followed by a search for unpublished studies. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments. Any disagreements that arose between the reviewers were resolved through discussion. Quantitative data was extracted from papers included in the review using the

  3. Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: The ACRA-Spasm study

    NARCIS (Netherlands)

    Van Der Heijden, D.J. (Dirk J.); M.A.H. van Leeuwen (Maarten); G.N. Janssens (Gladys N.); Hermie, J. (Jailen); M.J. Lenzen (Mattie); M.J.P.F. Ritt; P.M. van de Ven (Peter); F. Kiemeneij (Ferdinand); N. van Royen (Niels)

    2016-01-01

    textabstractAims: The aim of this study was to analyse the relation between endothelial dysfunction (ED) and the occurrence of radial artery spasm (RAS) during transradial coronary procedures. Methods and results: From May 2014 to June 2015, endothelial function was assessed by EndoPAT and FMD

  4. Comparison of the feasibility and effectiveness of transradial coronary angiography via right versus left radial artery approaches (from the PREVAIL Study).

    Science.gov (United States)

    Pelliccia, Francesco; Trani, Carlo; Biondi-Zoccai, Giuseppe G L; Nazzaro, Marco; Berni, Andrea; Patti, Giuseppe; Patrizi, Roberto; Pironi, Bruno; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio; Pristipino, Christian

    2012-09-15

    It remains undefined if transradial coronary angiography from a right or left radial arterial approach differs in real-world practice. To address this issue, we performed a subanalysis of the PREVAIL study. The PREVAIL study was a prospective, multicenter, observational survey of unselected consecutive patients undergoing invasive cardiovascular procedures over a 1-month observation period, specifically aimed at assessing the outcomes of radial approach in the contemporary real world. The choice of arterial approach was left to the discretion of the operator. Prespecified end points of this subanalysis were procedural characteristics. Of 1,052 patients consecutively enrolled, 509 patients underwent transradial catheterization, 304 with a right radial and 205 with a left radial approach. Procedural success rates were similar between the 2 groups. Compared to the left radial group, the right radial group had longer procedure duration (46 ± 29 vs 33 ± 24 minutes, p <0.0001) and fluoroscopy time (765 ± 787 vs 533 ± 502, p <0.0001). At multivariate analysis, including a parsimonious propensity score for the choice of left radial approach, duration of procedure (beta coefficient 11.38, p <0.001) and total dose-area product (beta coefficient 11.38, p <0.001) were independently associated with the choice of the left radial artery approach. The operator's proficiency in right/left radial approach did not influence study results. In conclusion, right and left radial approaches are feasible and effective to perform percutaneous procedures. In the contemporary real world, however, the left radial route is associated with shorter procedures and lower radiologic exposure than the right radial approach, independently of an operator's proficiency. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Patient radiation exposure in right versus left trans-radial approach for coronary procedures

    Energy Technology Data Exchange (ETDEWEB)

    Rigattieri, Stefano; Di Russo, Cristian; Cera, Maria; Fedele, Silvio; Sciahbasi, Alessandro [Interventional Cardiology Unit, Sandro Pertini Hospital, Rome (Italy); Pugliese, Francesco Rocco [Emergency Department Sandro Pertini Hospital, Rome (Italy)

    2015-01-15

    Objectives: The aim of this study was to compare radiation exposure, assessed by dose-area product (DAP), in right trans-radial approach (RR) versus left trans-radial approach (LR) for coronary procedures. Background: In LR the catheter course is more similar to trans-femoral approach, thus allowing an easier negotiation of coronary ostia which, in turn, might translate into reduced fluoroscopy time (FT) and radiation exposure as compared to RR. Methods: We retrospectively selected diagnostic and interventional procedures (PCI) performed by RR or LR at our center from May 2009 to May 2014. We only included in the analysis the procedures in which DAP values were available. Results: We analyzed 1464 procedures, 1175 of which performed by RR (80.3%) and 289 by LR (19.7%). Median DAP values were significantly higher in RR as compared to LR for diagnostic and interventional procedures (4482 vs. 3540 cGy.cm{sup 2} and 11523 vs. 10086 cGy.cm{sup 2}, respectively; p < 0.05). No significant differences were observed in FT and in contrast volume (CV). In the propensity-matched cohort, consisting of 269 procedures for each group, no significant differences between LR and RR were observed in median DAP values for both diagnostic and interventional procedures (3990 vs. 3542 cGy.cm{sup 2} and 9964 vs. 10216 cGy.cm{sup 2}, respectively; p = ns); FT and CV were also similar. At multiple linear regression analysis laterality of trans-radial approach was not associated with DAP. Conclusions: In an experienced trans-radial center LR is not associated with a reduction in radiation exposure, FT or CV as compared to RR. - Highlights: • Right trans-radial approach is by far more commonly used than left trans-radial approach. • Left trans-radial approach has the advantage of an easier catheter manipulation, more similar to trans-femoral approach. • This could reduce fluoroscopy time and radiation exposure. • We conducted a retrospective study to investigate patient radiation

  6. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    International Nuclear Information System (INIS)

    Rigattieri, Stefano; Valsecchi, Orazio; Sciahbasi, Alessandro; Tomassini, Francesco; Limbruno, Ugo; Marchese, Alfredo; La Manna, Alessio; Mauro, Ciro; Varbella, Ferdinando; Berti, Segio; Tarantino, Fabio F.; Musumeci, Giuseppe

    2017-01-01

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  7. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    Energy Technology Data Exchange (ETDEWEB)

    Rigattieri, Stefano, E-mail: stefanorigattieri@yahoo.it [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Valsecchi, Orazio [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy); Sciahbasi, Alessandro [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Tomassini, Francesco [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Limbruno, Ugo [Cardiology Unit, Azienda USL Toscana Sudest, Grosseto (Italy); Marchese, Alfredo [Interventional Cardiology Unit, Anthea Hospital, GVM Care & Research, Bari (Italy); La Manna, Alessio [Cardiovascular Department, Ferrarotto Hospital, University of Catania (Italy); Mauro, Ciro [Cardiovascular Department, Cardarelli Hospital, Napoli (Italy); Varbella, Ferdinando [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Berti, Segio [Department of Cardiology, Fondazione Toscana “Gabriele Monasterio”, Ospedale del Cuore, Massa (Italy); Tarantino, Fabio F. [Cardiology Unit, Ospedale G.B. Morgagni-L. Pierantoni, Forlì (Italy); Musumeci, Giuseppe [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy)

    2017-04-15

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  8. Combined Radial-Pedal Access Strategy and Radial-Pedal Rendezvous in the Revascularization of Complex Total Occlusions of the Superficial Femoral Artery (the "No Femoral Access" Strategy).

    Science.gov (United States)

    Hanna, Elias B; Prout, Davey L

    2016-04-01

    To describe the combined use of radial-pedal access for recanalization of complex superficial femoral artery (SFA) occlusions unsuitable for transfemoral recanalization. Patients are selected for this strategy if they have a long (≥ 10 cm) SFA occlusion with unfavorable aortoiliac anatomy, an absent ostial stump, or severely diseased and calcified distal reconstitution. Left radial artery and distal anterior or posterior tibial artery are accessed with 6-F and 4-F sheaths, respectively. The SFA lesion is crossed retrogradely with a 0.035-inch wire system. If retrograde crossing is not immediately successful, transradial subintimal tracking and radial-pedal subintimal rendezvous are used to allow retrograde reentry. Fifteen patients (mean age 62 ± 5 years; 11 men) have been treated in this fashion, and frequently stented, through the tibiopedal access. Seven patients required radial-pedal rendezvous to facilitate retrograde reentry. Two patients underwent transradial iliac stenting during the same session, and 1 patient underwent transradial kissing angioplasty of the profunda. No major complication occurred in any patient. After the procedure, the pulse across the accessed tibial artery was palpable in all patients. In patients with long and complex SFA occlusion unsuitable for transfemoral recanalization, a radial-pedal strategy can overcome revascularization obstacles. © The Author(s) 2016.

  9. Comparison of a priori versus provisional heparin therapy on radial artery occlusion after transradial coronary angiography and patent hemostasis (from the PHARAOH Study).

    Science.gov (United States)

    Pancholy, Samir B; Bertrand, Olivier F; Patel, Tejas

    2012-07-15

    Systemic anticoagulation decreases the risk of radial artery occlusion (RAO) after transradial catheterization and standard occlusive hemostasis. We compared the efficacy and safety of provisional heparin use only when the technique of patent hemostasis was not achievable to standard a priori heparin administration after radial sheath introduction. Patients referred for coronary angiography were randomized in 2 groups. In the a priori group, 200 patients received intravenous heparin (50 IU/kg) immediately after sheath insertion. In the provisional group, 200 patients did not receive heparin during the procedure. After sheath removal, hemostasis was obtained using a TR band (Terumo corporation, Tokyo, Japan) with a plethysmography-guided patent hemostasis technique. In the provisional group, no heparin was given if radial artery patency could be obtained and maintained. If radial patency was not achieved, a bolus of heparin (50 IU/kg) was given. Radial artery patency was evaluated at 24 hours (early RAO) and 30 days after the procedure (late RAO) by plethysmography. Patent hemostasis was obtained in 67% in the a priori group and 74% in the provisional group (p = 0.10). Incidence of RAO remained similar in the 2 groups at the early (7.5% vs 7.0%, p = 0.84) and late (4.5% vs 5.0%, p = 0.83) evaluations. Women, patients with diabetes, patients having not received heparin, and patients without radial artery patency during hemostasis had more RAO. By multivariate analysis, patent radial artery during hemostasis (odds ratio [OR] 0.03, 95% confidence interval [CI] 0.004 to 0.28, p = 0.002) and diabetes (OR 11, 95% CI 3 to 38,p patent hemostasis is maintained. Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Effectiveness of sublingual nitroglycerin before puncture compared with conventional intra-arterial nitroglycerin in transradial procedures: a randomized trial

    Energy Technology Data Exchange (ETDEWEB)

    Turan, Burak, E-mail: drburakturan@gmail.com; Daşlı, Tolga; Erkol, Ayhan; Erden, İsmail

    2015-10-15

    Aim: Sublingual (SL) nitroglycerin administered before radial artery puncture can improve cannulation success and decrease the incidence of radial artery spasm (RAS) compared with intra-arterial (IA) nitroglycerin in transradial procedures. Methods: Patients undergoing diagnostic transradial angiography were randomized to IA (200 mcg) or SL (400 mcg) nitroglycerin. Primary endpoints were puncture time and puncture attempts. Secondary endpoint was the incidence of RAS. Results: Total of 101 participants (mean age 60 ± 11 years, 53% male) were randomized (51 in IA and 50 in SL groups). Puncture time (50 [36–75] vs 50 [35–90] sec), puncture attempts (1.18 ± 0.48 vs 1.20 ± 0.49), multiple punctures (13.7 vs 16.0%) and RAS (19.6 vs 24.0%) were not statistically different between IA vs SL groups respectively. A composite endpoint of all adverse events related to transradial angiography (multiple punctures, RAS, access site crossover, hypotension/bradycardia associated with nitroglycerin and radial artery occlusion) was very similar in IA vs SL groups (39 vs 40%, respectively). However puncture time was significantly longer with SL nitroglycerin in patients < 1.65 m height (47 [36–66] vs 63 [41–110] sec, p = 0.042). Multiple punctures seemed higher with SL nitroglycerin in patients with diabetes (0 vs 30%, p = 0.028) or in patients < 1.65 m height (7.4 vs 25%, p = 0.085). Likewise, RAS with SL nitroglycerin seemed more frequent in smokers compared to IA nitroglycerin (0 vs 27%, p = 0.089). Conclusions: SL nitroglycerin was not different from IA nitroglycerin in terms of efficiency and safety in overall study population. However it may be inferior to IA nitroglycerin in certain subgroups (shorter individuals, diabetics and smokers). - Highlights: • Improvement in radial artery puncture time and success with subcutaneous nitrate was reported. • Giving nitrate sublingually may have vasodilation along entire length of radial artery and may prevent RAS

  11. Intra-arterial vasodilators to prevent radial artery spasm: a systematic review and pooled analysis of clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, Chun Shing, E-mail: shingkwok@doctors.org.uk [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Rashid, Muhammad [St. Helens & Knowsley Teaching Hospital (NHS) Trust, Whiston Hospital, Prescot (United Kingdom); Fraser, Doug [Manchester Heart Centre, Manchester Royal Infirmary (United Kingdom); Nolan, James [University Hospital of North Midlands, Stoke-on-Trent (United Kingdom); Mamas, Mamas [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Farr Institute, Institute of Population Health, University of Manchester, Manchester (United Kingdom)

    2015-12-15

    Objectives: The aim of this study is to review the available literature on the efficacy and safety of agents used for prevention of RAS. Background: Different vasodilator agents have been used to prevent radial artery spasm (RAS) in patients undergoing transradial cardiac catheterization. Methods: We included studies that evaluated any intra-arterial drug administered in the setting cardiac catheterization that was undertaken through the transradial access site (TRA). We also compared studies for secondary outcomes of major bleeding, procedure time, and procedure failure rate in setting of RAS prevention, patent hemostasis and radial artery occlusion. Results: 22 clinical studies met the inclusion criteria. For placebo, RAS rate was 12% (4 studies, 638 participants), which was similar to 2.5 mg of verapamil 12% (3 studies, 768 participants) but greater than 5 mg of verapamil (4%, 2 studies, 497 participants). For nicorandil, there was a much higher RAS rate compared to placebo (16%, 3 studies, 447 participants). The lowest rates of RAS was found for nitroglycerin at both 100 μg (4%) and 200 μg (2%) doses, isosorbide mononitrate (4%) and nicardipine (3%). We found no information regarding the procedure failure rates, patent hemostasis, and radial artery occlusion in these studies. Conclusions: In this largest and up-to-date review on intra-arterial vasodilators use to reduce RAS, we have found that the verapamil at a dose of 5 mg or verapamil in combination with nitroglycerine are the best combinations to reduce RAS. - Highlights: • Radial artery spasm (RAS) causes procedural failure in transradial catheterization. • RAS may complicate 10–15% procedures undertaken through the radial approach. • We reviewed the efficacy of vasodilators that have been used to minimize RAS. • The pooled RAS rate was lowest with 5 mg of verapamil (4%) compared to placebo (12%). • The best combination of drugs to minimize RAS is nitroglycerine and verapamil.

  12. Access site-related complications after transradial catheterization can be reduced with smaller sheath size and statins.

    Science.gov (United States)

    Honda, Tsuyoshi; Fujimoto, Kazuteru; Miyao, Yuji; Koga, Hidenobu; Hirata, Yoshihiro

    2012-09-01

    The aim of this study was to investigate the risk factors for access site-related complications after transradial coronary angiography (CAG) or percutaneous coronary intervention (PCI). Transradial PCI has been shown to reduce access site-related bleeding complications compared with procedures performed through a femoral approach. Although previous studies focused on risk factors for access site-related complications after a transfemoral approach or transfemoral and transradial approaches, it is uncertain which factors affect vascular complications after transradial catheterization. We enrolled 500 consecutive patients who underwent transradial CAG or PCI. We determined the incidence and risk factors for access site-related complications such as radial artery occlusion and bleeding complications. Age, sheath size, the dose of heparin and the frequency of PCI (vs. CAG) were significantly greater in patients with than without bleeding complications. However, body mass index (BMI) was significantly lower in patients with than without bleeding complications. Sheath size was significantly higher and the frequency of statin use was significantly lower in patients with than without radial artery occlusion. Multiple logistic analysis revealed that sheath size [odds ratio (OR) 5.5; P strategy that could prevent radial artery occlusion after transradial procedures.

  13. Radial artery approach for coronary intervention - early experience

    International Nuclear Information System (INIS)

    Jan, H.; Hadi, A.; Fahim, M.; Gul, A.M.; Irfan, M.; Khan, S.B.; Hafizullah, M.

    2012-01-01

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  14. Radial artery approach for coronary intervention - early experience

    Energy Technology Data Exchange (ETDEWEB)

    Jan, H; Hadi, A; Fahim, M; Gul, A M; Irfan, M; Khan, S B; Hafizullah, M [Lady Reading Hospital and Khyber Medical University, Peshawar (Pakistan). Dept. of Cardiology

    2012-01-15

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  15. The transradial approach for selective carotid and vertebral angiography

    Energy Technology Data Exchange (ETDEWEB)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Radiology; Yokoyama, K. [Higashiosaka City General Hospital, Osaka (Japan). Dept. of Neurosurgery; Takayama, K.; Nakagawa, H.; Kichikawa, K. [Nara Medical Univ., Osaka (Japan). Dept. of Radiology

    2002-11-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications.

  16. The transradial approach for selective carotid and vertebral angiography

    International Nuclear Information System (INIS)

    Iwasaki, S.; Ueda, K.; Sueyosi, S.; Nagasawa, M.; Ude, K.; Yokoyama, K.; Takayama, K.; Nakagawa, H.; Kichikawa, K.

    2002-01-01

    Purpose: The transradial approach is not so popular in cerebral angiography. The purpose of this study was therefore to present our experience of success rate and safety of this method. Material and Methods: From December 1998 to June 2001, 526 carotid and vertebral angiographies with DSA were performed via the radial artery. A 1.4-mm catheter was used through a 1.4-mm introducer sheath. We evaluated the procedure as successful if sufficient images for diagnosis were obtained of the bilateral carotid arteries and unilateral vertebral artery. Each patient was reassessed for any complications, occurring until the next morning. The length of time needed for an examination was measured in the last 10 cases. Results: In all but 5 cases, the procedures were evaluated as successful (99.0%). Unsuccessful cases manifested severe pain at the radial puncture, angiospasm at the radial artery, loop formation at the radial artery, occlusion at the subclavian artery, and an aberrant right subclavian artery. No severe complications including neurological ones were encountered. Minor complications were noted in 17 cases (3.2%): 4 cases of thrombus at the ulnar artery, 1 angiospasm at the radial artery, and 12 cases of small hematoma at the puncture site. The radial approach took 14 min less in the common carotid study and 3 min 30 s less in the internal carotid study than by the femoral approach. Conclusion: The transradial approach enabled selective studies for carotid and vertebral angiography with a high success rate and safety with few complications

  17. Feasibility and utility of transradial cerebral angiography: experience during the learning period

    International Nuclear Information System (INIS)

    Kim, Ji Hyung; Park, Yong Sung; Chung, Chul Gu; Park, Kyeong Sug; Chung, Dong Jin; Kim, Hyun Jin

    2006-01-01

    We wanted to present our experiences for performing transradial cerebral angiography during the learning period, and we also wanted to demonstrate this procedure's technical feasibility and utility in various clinical situations. Thirty-two patients were enrolled in the study. All of them had unfavorable situations for performing transfemoral angiography, i.e., IV lines in the bilateral femoral vein, a phobia for groin puncture, decreased blood platelet counts, large hematoma or bruise, atherosclerosis in the bilateral femoral artery and the insistence of patients for choosing another procedure. After con firming the patency of the ulnar artery with a modified Allen's test and a pulse oximeter, the procedure was done using a 21-G micorpuncture set and 5-F Simon II catheters. After angiography, hemostasis was achieved with 1-2 minutes of manual compression and the subsequent application of a hospital-made wrist brace for two hours. The technical feasibility and procedure-related immediate and delayed complications were evaluated. The procedure was successful in 30/32 patients (93.8%). Failure occurred in two patients; one patient had hypoplasia of the radial artery and one patient had vasospasm following multiple puncture trials for the radial artery. Transradial cerebral angiography was technically feasible without significant difficulties even though it was tried during the learning period. Pain in the forearm or arm developed in some patients during the procedures, but this was usually mild and transient. Procedure-related immediate complications included severe bruising in one patient and a small hematoma in one patient. Any clinically significant complication or delayed complication such as radial artery occlusion was not demonstrated in our series. Transradial cerebral angiography is a useful alternative for the patients who have unfavorable clinical situations or contraindications for performing transfemoral cerebral angiography. For the experienced

  18. Feasibility and utility of transradial cerebral angiography: experience during the learning period

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Ji Hyung; Park, Yong Sung; Chung, Chul Gu; Park, Kyeong Sug; Chung, Dong Jin; Kim, Hyun Jin [Konyang University Hospital, Daejeon (Korea, Republic of)

    2006-03-15

    We wanted to present our experiences for performing transradial cerebral angiography during the learning period, and we also wanted to demonstrate this procedure's technical feasibility and utility in various clinical situations. Thirty-two patients were enrolled in the study. All of them had unfavorable situations for performing transfemoral angiography, i.e., IV lines in the bilateral femoral vein, a phobia for groin puncture, decreased blood platelet counts, large hematoma or bruise, atherosclerosis in the bilateral femoral artery and the insistence of patients for choosing another procedure. After con firming the patency of the ulnar artery with a modified Allen's test and a pulse oximeter, the procedure was done using a 21-G micorpuncture set and 5-F Simon II catheters. After angiography, hemostasis was achieved with 1-2 minutes of manual compression and the subsequent application of a hospital-made wrist brace for two hours. The technical feasibility and procedure-related immediate and delayed complications were evaluated. The procedure was successful in 30/32 patients (93.8%). Failure occurred in two patients; one patient had hypoplasia of the radial artery and one patient had vasospasm following multiple puncture trials for the radial artery. Transradial cerebral angiography was technically feasible without significant difficulties even though it was tried during the learning period. Pain in the forearm or arm developed in some patients during the procedures, but this was usually mild and transient. Procedure-related immediate complications included severe bruising in one patient and a small hematoma in one patient. Any clinically significant complication or delayed complication such as radial artery occlusion was not demonstrated in our series. Transradial cerebral angiography is a useful alternative for the patients who have unfavorable clinical situations or contraindications for performing transfemoral cerebral angiography. For the experienced

  19. Prevalence of chronic kidney disease among patients undergoing transradial percutaneous coronary interventions.

    Science.gov (United States)

    Hossain, Mohammad A; Quinlan, Amy; Heck-Kanellidis, Jennifer; Calderon, Dawn; Patel, Tejas; Gandhi, Bhavika; Patel, Shrinil; Hetavi, Mahida; Costanzo, Eric J; Cosentino, James; Patel, Chirag; Dewan, Asa; Kuo, Yen-Hong; Salman, Loay; Vachharajani, Tushar J

    2018-03-01

    While transradial approach to conduct percutaneous coronary interventions offers multiple advantages, the procedure can cause radial artery damage and occlusion. Because radial artery is the preferred site for the creation of an arteriovenous fistula to provide dialysis, patients with chronic kidney disease are particularly dependent on radial artery for their long-term survival. In this retrospective study, we investigated the prevalence of chronic kidney disease in patients undergoing coronary interventions via radial artery. Stage of chronic kidney disease was based on estimated glomerular filtration rate and National Kidney Foundation - Kidney Disease Outcomes Quality Initiative guidelines. A total of 497 patients undergoing transradial percutaneous coronary interventions were included. Over 70.4% (350/497) of the patients had chronic kidney disease. Stage II chronic kidney disease was observed in 243 (69%) patients (estimated glomerular filtration rate = 76.0 ± 8.4 mL/min). Stage III was observed in 93 (27%) patients (estimated glomerular filtration rate = 49 ± 7.5 mL/min). Stage IV chronic kidney disease was observed in 5 (1%) patients (estimated glomerular filtration rate = 25.6 ± 4.3 mL/min) and Stage V chronic kidney disease was observed in 9 (3%) patients (estimated glomerular filtration rate = 9.3 ± 3.5 mL/min). Overall, 107 of 350 patients (30%) had advanced chronic kidney disease, that is, stage III-V chronic kidney disease. Importantly, 14 of the 107 (13%) patients had either stage IV or V chronic kidney disease. This study finds that nearly one-third of the patients undergoing transradial percutaneous coronary interventions have advanced chronic kidney disease. Because many of these patients may require dialysis, the use of radial artery to conduct percutaneous coronary interventions must be carefully considered in chronic kidney disease population.

  20. Transradial access for coronary angiography: a single operator's experience of 500 cases

    International Nuclear Information System (INIS)

    Ali, J.; Aziz, S.; Javed, A.; Kayani, A.M.

    2011-01-01

    Objective: The purpose of the present study was to assess the feasibility, success, and safety of the transradial approach (TRA) for diagnostic coronary angiography. Study Design: Descriptive study. Place and Duration of Study: The study was carried out in Armed Forces Institute of Cardiology- National Institute of Heart Diseases (AFIC-NIHD) over a period of ten months from June 2009 to March 2010. Patients and Methods: We collected data of 500 consecutive patients who underwent coronary catheterization by the transradial approach. Transradial access was performed only if the Allen's test was normal (positive). Patients with previous CABG or requiring right heart catheterization were excluded from this study. Study endpoints included procedure success rate, vascular complications at access site, and major adverse cardiac and cerebrovascular events during hospitalization. Results: Mean age of the patients was 52 years (range 33-77 yrs) and 72.8% (n= 364) were men and 27.2% (n=136) were females. The vast majority of cases (98.4%) were elective. The right radial artery was used in 98% of cases. Procedural success was achieved in 90.6% cases (453/500). No case of vascular complications such as major access site bleeding, vascular perforation, radial artery occlusion, forearm ischemia, compartment syndrome or MACE was observed. Conclusion: Transradial access for coronary angiography is a safe, effective and elegant alternative to trans femoral access. (author)

  1. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    Science.gov (United States)

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  2. Incidence of vascular complications in patients submitted to percutaneous transluminal coronary angioplasty by transradial and transfemoral arterial approach Incidencia de complicaciones vasculares en pacientes sometidos a angioplastía coronaria transluminal percutánea por vía arterial transradial y transfemoral Incidência de complicações vasculares em pacientes submetidos a angioplastia coronariana transluminal percutânea por via arterial transradial e transfemoral

    Directory of Open Access Journals (Sweden)

    Marinez Kellermann Armendaris

    2008-03-01

    Full Text Available OBJECTIVE: To describe the vascular complications of transradial and transfemoral artery punctures in patients submitted to percutaneous transluminal coronary angioplasty (PTCA. METHODS: Prospective cohort study including patients submitted to PTCA. An interview was performed and an instrument applied to collect risk factors/predictors of complications. After the procedure, a physical examination was performed, vital signs were measured and the puncture site was assessed. RESULTS: 199 patients were included, age 64±10 years. Complications found for the radial and femoral approach were respectively: ecchymosis (18.29%, (17.14%; bruising (17.66%, (14.27%; urinary retention (2.43%, (25.71%; loss of vessel permeability (8.53%, (0%. CONCLUSION: The complications found were considered minor or secondary, depending on the classification found in literature. A higher rate of vascular complications related to transradial artery punctures compared to the interventions performed by transfemoral approach.OBJETIVO: Describir complicaciones vasculares relacionadas a punciones arteriales transradial y transfemoral en pacientes sometidos a angioplastía coronaria transluminal percutánea (ACTP. MÉTODOS: Se trata de un estudio de cohorte prospectivo realizado con pacientes sometidos a ACTP. Se llevó a cabo una entrevista y aplicó un instrumento para obtener factores de riesgo/predictores. Fue realizado un examen físico, medición de signos vitales y se evaluó el lugar de punción. RESULTADOS: Fueron incluidos 199 pacientes, edad 64±10 años. Las complicaciones encontradas para vía radial y femoral respectivamente, fueron: esquimosis (18,29%, (17,14%; hematoma (17,66%, (14,27%; retención urinaria (2,43%, (25,71%; pérdida de permeabilidad de vaso (8,53%, (0%. CONCLUSIÓN: Las complicaciones fueron consideradas menores o secundarias conforme clasificación literaria. Existe una mayor incidencia de complicaciones vasculares relacionadas a punciones

  3. Endovascular Therapy of the Superficial Femoral Artery Via a Stand-Alone Transradial Access: A Single-Center Experience.

    Science.gov (United States)

    Hanna, Elias B; Ababneh, Bashar A; Amin, Amit N

    2018-02-01

    We describe our experience in transradial recanalization of the superficial femoral artery (SFA), and we provide a stepwise approach accounting for the patient's height and optimizing the yield of currently available devices. Fifteen patients with simple SFA disease, including 4 patients with total SFA occlusions monorail balloons) in all patients, and orbital atherectomy in 6 patients. We illustrate the steps and challenges of the transradial approach, namely the limited support in complex disease and the limited reach of current equipment. In patients with simple SFA disease, transradial recanalization appears feasible and safe but currently limited to balloon angioplasty ± orbital atherectomy. Proximal SFA stenting may be feasible in patients <160 cm in height.

  4. Trans-radial Primary Percutaneous Coronary Intervention in ST-Elevation Myocardial Infarction

    International Nuclear Information System (INIS)

    Hussain, S.; Kayani, A. M.; Munir, R.

    2014-01-01

    Objective: To study the effect of trans-radial approach (TRA) on achievement of a door-to-balloon time (DBT) of A/sup 2/ 90 minutes in primary PCI percutaneous coronary intervention (PPCI) for ST-elevation myocardial infarction (STEMI). Study Design: Case series. Place and Duration of Study: Armed Forces Institute of Cardiology - National Institute of Heart Diseases (AFIC -NIHD), Rawalpindi, from October 2011 to August 2012. Methodology: Systems goal for door-to-balloon time (DBT - time elapsed between first medical contact and restoration of flow in the infarct related artery (IRA)) was set at < 90 minutes. Procedural success was defined as restoration of TIMI 3 flow in the IRA with less than 30% residual stenosis and discharge from hospital. Non-infarct related arteries were not treated. Bleeding episodes were defined by TIMI definitions. Results: For vascular access for PPCI in a total of 207 patients, TRA was 91.3% (n = 189), transfemoral approach (TFA) 6.3% (n = 13) and brachial 2.4% (n = 5). Males represented 90.3% of cases and 7% were females. Mean age was 55 A +- 10.86 years. Procedural success rate was 97.1%. Mean DBT was 54.1 minutes. DBT was less A/sup 2/ 60 and 90 minutes in 75% and 94.2% of patients respectively. DBT A/sup 2/ 89.50 minutes was achieved in 90% of patients. The difference in DBT between the different access groups was not markedly different between the three groups. There were 6 (2.9%) in-hospital deaths and no major bleeds. Conclusion: TRA for PPCI poses no hindrance to achieving a DBT of < 90 minutes in PPCI for STEMI. Furthermore, the in-hospital mortality rates are acceptable and within rational limits. (author)

  5. Comparison of the patient radiation exposure during coronary angiography and angioplasty procedures using trans-radial and trans-femoral access

    Directory of Open Access Journals (Sweden)

    Ali Tarighatnia

    2016-06-01

    Conclusion: On the basis of the results obtained in this study, no differences were found in patients’ radiation dose in both access groups, therefore with regard to comparatively more clinical advantages associated with the Trans-radial access technique it might be a good substitute for Trans-femoral access.

  6. Morphological and functional consequences of transradial coronary angiography on the radial artery: implications for its use as a bypass conduit.

    Science.gov (United States)

    Gaudino, Mario; Leone, Alessandro; Lupascu, Andrea; Toesca, Amelia; Mazza, Andrea; Ponziani, Francesca Romana; Flore, Roberto; Tondi, Paolo; Massetti, Massimo

    2015-09-01

    To assess the degree of damage to the radial artery (RA) in coronary artery bypass grafting (CABG) patients who underwent preoperative transradial coronary angiography (RA-CA). From May 2012 to October 2013, 50 consecutive CABG patients who underwent RA-CA were prospectively enrolled in the study. All patients underwent echo-Doppler evaluation of the RA of the catheterized arm; the contralateral RA was used as control. The distal segment of the RA was submitted to immunohistochemical assessment of endothelial integrity. Patients were divided in three groups according to the time interval from angiography to evaluation: ≤24 h, >24 h to <7 days and ≥7 days. Baseline RA median diameters were 0.25 ± 0.04 cm in the cannulated arm and 0.22 ± 0.04 cm in the non-cannulated arm (P = 0.01). The flow-mediated dilatation (FMD) in the RA in the catheterized arm and in the control arm were 11.6 ± 7.9 and 14.2 ± 8.9 (P = 0.01), respectively. A statistically significant correlation was found between FMD of the catheterized RA and the time from RA-CA (Pearson's r = 0.348). Linear regression analysis confirmed that the FMD of the catheterized RA was dependent on days elapsed from the procedure (P = 0.032; OR 1.11, CI 0.009-0.203). Immunohistochemical evaluation showed extensive endothelial lesion in all examined RAs, with a trend towards reduction of the damage with time. Endothelial function and integrity of the cannulated arm did not reach those of the control arm in any of the study patients. RA-CA produces extensive damage to the RA. The lesions tend to heal with time but incomplete recovery of endothelial integrity and function is still present more than 30 days after the procedure. After RA-CA, the cannulated RA should not be used for CABG. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  7. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  8. Comparison of Hemostasis Times With a Kaolin-Based Hemostatic Pad (QuikClot Radial) vs Mechanical Compression (TR Band) Following Transradial Access: A Pilot Prospective Study.

    Science.gov (United States)

    Roberts, Jonathan S; Niu, Jianli; Pastor-Cervantes, Juan A

    2017-10-01

    Hemostasis following transradial access (TRA) is usually achieved by mechanical compression. We investigated use of the QuikClot Radial hemostasis pad (Z-Medica) compared with the TR Band (Terumo Medical) to shorten hemostasis after TRA. Thirty patients undergoing TRA coronary angiography and/or percutaneous coronary intervention were randomized into three cohorts post TRA: 10 patients received mechanical compression with the TR Band, 10 patients received 30 min of compression with the QuikClot Radial pad, and 10 patients received 60 min of compression with the QuikClot Radial pad. Times to hemostasis and access-site complications were recorded. Radial artery patency was evaluated 1 hour after hemostasis by the reverse Barbeau's test. There were no differences in patient characteristics, mean dose of heparin (7117 ± 1054 IU), or mean activated clotting time value (210 ± 50 sec) at the end of procedure among the three groups. Successful hemostasis was achieved in 100% of patients with both the 30-min and 60-min compression groups using the QuikClot pad. Hemostasis failure occurred in 50% of patients when the TR Band was initially weaned at the protocol-driven time (40 min after sheath removal). Mean compression time for hemostasis with the TR Band was 149.4 min compared with 30.7 min and 60.9 min for the 30-min and 60-min QuikClot groups, respectively. No radial artery occlusion occurred in any subject at the end of the study. Use of the QuikClot Radial pad following TRA in this pilot trial significantly shortened hemostasis times when compared with the TR Band, with no increased complications noted.

  9. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX - RAdiation Dose study (RAD-MATRIX).

    Science.gov (United States)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-06-01

    Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    International Nuclear Information System (INIS)

    Sciahbasi, Alessandro; Calabrò, Paolo; Sarandrea, Alessandro; Rigattieri, Stefano; Tomassini, Francesco; Sardella, Gennaro; Zavalloni, Dennis; Cortese, Bernardo; Limbruno, Ugo; Tebaldi, Matteo; Gagnor, Andrea; Rubartelli, Paolo; Zingarelli, Antonio; Valgimigli, Marco

    2014-01-01

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes

  11. Randomized comparison of operator radiation exposure comparing transradial and transfemoral approach for percutaneous coronary procedures: rationale and design of the minimizing adverse haemorrhagic events by TRansradial access site and systemic implementation of angioX – RAdiation Dose study (RAD-MATRIX)

    Energy Technology Data Exchange (ETDEWEB)

    Sciahbasi, Alessandro, E-mail: alessandro.sciahbasi@fastwebnet.it [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Calabrò, Paolo [Division of Cardiology - Department of Cardio-Thoracic Sciences - Second University of Naples (Italy); Sarandrea, Alessandro [HSE Management, Rome (Italy); Rigattieri, Stefano [Interventional Cardiology, Sandro Pertini Hospital – ASL RMB, Rome (Italy); Tomassini, Francesco [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Sardella, Gennaro [La Sapienza University, Rome (Italy); Zavalloni, Dennis [UO Emodinamica e Cardiologia Invasiva, IRCCS, Istituto Clinico Humanitas, Rozzano (Italy); Cortese, Bernardo [Interventional Cardiology, Fatebenefratelli Hospital, Milan (Italy); Limbruno, Ugo [Cardiology Unit, Misericordia Hospital, Grosseto (Italy); Tebaldi, Matteo [Cardiology Department, University of Ferrara, Department of Cardiology (Italy); Gagnor, Andrea [Department of Cardiology, Infermi Hospital, Rivoli (Italy); Rubartelli, Paolo [Villa Scassi Hospital, Genova (Italy); Zingarelli, Antonio [San Martino Hospital, Genova (Italy); Valgimigli, Marco [Thoraxcenter, Rotterdam (Netherlands)

    2014-06-15

    Background: Radiation absorbed by interventional cardiologists is a frequently under-evaluated important issue. Aim is to compare radiation dose absorbed by interventional cardiologists during percutaneous coronary procedures for acute coronary syndromes comparing transradial and transfemoral access. Methods: The randomized multicentre MATRIX (Minimizing Adverse Haemorrhagic Events by TRansradial Access Site and Systemic Implementation of angioX) trial has been designed to compare the clinical outcome of patients with acute coronary syndromes treated invasively according to the access site (transfemoral vs. transradial) and to the anticoagulant therapy (bivalirudin vs. heparin). Selected experienced interventional cardiologists involved in this study have been equipped with dedicated thermoluminescent dosimeters to evaluate the radiation dose absorbed during transfemoral or right transradial or left transradial access. For each access we evaluate the radiation dose absorbed at wrist, at thorax and at eye level. Consequently the operator is equipped with three sets (transfemoral, right transradial or left transradial access) of three different dosimeters (wrist, thorax and eye dosimeter). Primary end-point of the study is the procedural radiation dose absorbed by operators at thorax. An important secondary end-point is the procedural radiation dose absorbed by operators comparing the right or left radial approach. Patient randomization is performed according to the MATRIX protocol for the femoral or radial approach. A further randomization for the radial approach is performed to compare right and left transradial access. Conclusions: The RAD-MATRIX study will probably consent to clarify the radiation issue for interventional cardiologist comparing transradial and transfemoral access in the setting of acute coronary syndromes.

  12. Usefulness of Interventional Treatment for Dysfunctional Hemodialysis Shunts of the Upper Arm by Means of the Retrograde Transradial Approach

    International Nuclear Information System (INIS)

    Shin, Hwa Seon; Shin, Tae Beom; Na, Jae Beom; Jung, Seong Hoon; Kim, Hyun Jung; Lee, Jung Eun; Song, Yun Gyu; Jung, Gyoo Sik

    2010-01-01

    This study was designed to evaluate the technical feasibility and clinical outcome of endovascular intervention using the retrograde transradial approach to treat dysfunctional hemodialysis shunts of the upper arms. During the last 3 years, sixteen procedures were performed by the transradial approach in 13 patients with dysfunctional hemodialysis shunts of the upper arms. The radial artery was accessed with the use of 20-gauge needle and a 6-Fr sheath. Angiography was performed using a 5-Fr catheter placed in the brachial artery, and then the interventional procedure was performed. The technical and clinical success rates, complications and patency rates were evaluated. Fistulography and percutaneous transluminal angioplasty via the transradial approach were performed in 16 cases of the 13 patients. Fistulography demonstrated stenosis in 7 cases and occlusions in 9 cases. Lesion multiplicity was identified in 9 out of 16 cases. Balloon angioplasty was performed in all cases and a stent was placed to overcome restenosis or to treat venous rupture in two cases. The technical success rate of balloon angioplasty was 87.5% (14/16) and the technical success rate with including stent insertion was 100% (16/16). The clinical success rate was 93.8%. There was one procedural-related complication. The primary patency rates at 6 and 12 months were 84.6% and 74%, respectively. The transradial approach seems to be technically feasible and effective for the management of insufficient hemodialysis shunts of the upper arms

  13. Anomalies of radial and ulnar arteries

    Directory of Open Access Journals (Sweden)

    Rajani Singh

    Full Text Available Abstract During dissection conducted in an anatomy department of the right upper limb of the cadaver of a 70-year-old male, both origin and course of the radial and ulnar arteries were found to be anomalous. After descending 5.5 cm from the lower border of the teres major, the brachial artery anomalously bifurcated into a radial artery medially and an ulnar artery laterally. In the arm, the ulnar artery lay lateral to the median nerve. It followed a normal course in the forearm. The radial artery was medial to the median nerve in the arm and then, at the level of the medial epicondyle, it crossed from the medial to the lateral side of the forearm, superficial to the flexor muscles. The course of the radial artery was superficial and tortuous throughout the arm and forearm. The variations of radial and ulnar arteries described above were associated with anomalous formation and course of the median nerve in the arm. Knowledge of neurovascular anomalies are important for vascular surgeons and radiologists.

  14. Combined Radial and Femoral Access Strategy and Radial-Femoral Rendezvous in Patients With Long and Complex Iliac Occlusions.

    Science.gov (United States)

    Hanna, Elias B; Mogabgab, Owen N; Baydoun, Hassan

    2018-01-01

    We present cases of complex, calcified iliac occlusive disease revascularized via a combined radial-femoral access strategy. Through a 6-French, 125-cm transradial guiding catheter, antegrade guidewires and catheters are advanced into the iliac occlusion, while retrograde devices are advanced transfemorally. The transradial and transfemoral channels communicate, allowing the devices to cross the occlusion into the true lumen (radial-femoral antegrade-retrograde rendezvous).

  15. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  16. Intraluminal milrinone for dilation of the radial artery graft.

    Science.gov (United States)

    García-Rinaldi, R; Soltero, E R; Carballido, J; Mojica, J

    1999-01-01

    There is renewed interest in the use of the radial artery as a conduit for coronary artery bypass surgery. The radial artery is, however, a very muscular artery, prone to vasospasm. Milrinone, a potent vasodilator, has demonstrated vasodilatory properties superior to those of papaverine. In this report, we describe our technique of radial artery harvesting and the adjunctive use of intraluminal milrinone as a vasodilator in the preparation of this conduit for coronary artery bypass grafting. We have used these techniques in 25 patients who have undergone coronary artery bypass grafting using the radial artery. No hand ischemic complications have been observed in this group. Intraluminal milrinone appears to dilate and relax the radial artery, rendering this large conduit spasm free and very easy to use. We recommend the skeletonization technique for radial artery harvesting and the use of intraluminal milrinone as a radial artery vasodilator in routine myocardial revascularization. PMID:10524740

  17. Ulnar Artery Compression: A Feasible and Effective Approach to Prevent the Radial Artery Occlusion after Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Jun Tian

    2015-01-01

    Full Text Available Background: Radial artery (RA occlusion (RAO is not rare in patients undergoing coronary intervention by transradial approach (TRCI. Predictors of and prevention from RAO have not been systematically studied. This study aimed to analyze the risk factors of the weakness of RA pulsation (RAP and its predictive value for RAO after TRCI, and simultaneously to describe a feasible and effective approach to maintain RA patency. Methods: Between June 2006 and March 2010, all patients who underwent TRCI were classified according to the weakness of RAP after removing compression bandage with confirmation by Doppler ultrasound for the first 30 consecutive patients. Among a total of 2658 patients studied, 187 (7% patients having a weaker RAP were prospectively monitored. At 1 h after bandage removal, the ulnar artery in puncture side of all patients was blocked with manual compression to favor brachial and collateral artery blood flow through the RA until a good RAP was restored. The primary analysis was the occurrence of RAO. Results: Doppler ultrasound demonstrated the significant reduction of both systolic velocity (61.24 ± 3.95 cm/s vs. 72.31 ± 3.57 cm/s and diastolic velocity (1.83 ± 0.32 cm/s vs. 17.77 ± 3.97 cm/s in RA at access side as compared to the contralateral RA (all P < 0.001, but these velocities in ipsilateral ulnar artery (81.2 ± 2.16 cm/s and 13.1 ± 2.86 cm/s, respectively increased profoundly. The average time of ulnar artery compression was 4.1 ± 1.2 h (ranged 2.5-6.5 h. There were two patients experienced persistent RAO with a success rate of 98.9% and RAO in 0.075% of patients after ulnar artery compression was applied. The pulsation of the ulnar artery after compression was removed had not been influenced by the compression. Conclusions: After intervention using TRCI approach, the presence of a weaker RAP is an indicator of imminent RAO. The continuing compression of ipsilateral ulnar artery is an effective approach to

  18. Sharp Dissection versus Electrocautery for Radial Artery Harvesting

    Science.gov (United States)

    Marzban, Mehrab; Arya, Reza; Mandegar, Mohammad Hossein; Karimi, Abbas Ali; Abbasi, Kiomars; Movahed, Namvar; Abbasi, Seyed Hesameddin

    2006-01-01

    Radial arteries have been increasingly used during the last decade as conduits for coronary artery revascularization. Although various harvesting techniques have been described, there has been little comparative study of arterial damage and patency. A radial artery graft was used in 44 consecutive patients, who were randomly divided into 2 groups. In the 1st group, the radial artery was harvested by sharp dissection and in the 2nd, by electrocautery. These groups were compared with regard to radial artery free flow, harvest time, number of clips used, complications, and endothelial damage. Radial artery free flow before and after intraluminal administration of papaverine was significantly greater in the electrocautery group (84.3 ± 50.7 mL/min and 109.7 ± 68.5 mL/min) than in the sharp-dissection group (52.9 ± 18.3 mL/min and 69.6 ± 28.2 mL/ min) (P =0.003). Harvesting time by electrocautery was significantly shorter (25.4 ± 4.3 min vs 34.4 ± 5.9 min) (P =0.0001). Electrocautery consumed an average of 9.76 clips, versus 22.45 clips consumed by sharp dissection. The 2 groups were not different regarding postoperative complications, except for 3 cases of temporary paresthesia of the thumb in the electrocautery group; histopathologic examination found no endothelial damage. We conclude that radial artery harvesting by electrocautery is faster and more economical than harvesting by sharp dissection and is associated with better intraoperative flow and good preservation of endothelial integrity. PMID:16572861

  19. Intervenção coronariana percutânea primária pelo acesso transulnar: segurança e eficácia Primary percutaneous coronary intervention through transulnar approach: safety and effectiveness

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2008-10-01

    Full Text Available O acesso transradial é seguro e eficaz na realização de procedimentos coronários. Porém, seu uso pode estar comprometido em casos de variações anatômicas da artéria radial, espasmo e negatividade do teste de Allen. O acesso transulnar surge como uma alternativa viável em substituição à abordagem transradial. Reportamos o caso de um paciente submetido à angioplastia primária pela via ulnar com sucesso, sem complicações isquêmicas da mão, a despeito de oclusão prévia da artéria radial correspondente.The transradial approach is safe and effective for coronary procedures. However, its use may be compromised in cases of variations in radial artery anatomy, spasms, and negative Allen's test. The transulnar approach emerges as a viable alternative to transradial approach. We report on a patient who underwent primary angioplasty via ulnar artery without ischemic hand complications despite prior occlusion of the ipsilateral radial artery.

  20. Patient Versus Physician Variation in Use of Transradial Percutaneous Coronary Intervention.

    Science.gov (United States)

    Shamim, Shariq; Tang, Fengming; Safley, David; Jones, Philip; Spertus, John A; Baklanov, Dmitri

    2017-06-15

    The prevalence of radial access for transradial catheterization remains low in the United States, occurring in only 28% of cases in the National Cardiovascular Data Registry (NCDR) CathPCI. It is unknown whether the low adoption rate has been influenced by patient characteristics or is more operator dependent. In a 10-center study, we compared clinical and demographic characteristics among 323 radial and 1,506 femoral access percutaneous coronary intervention (PCIs) performed by 65 interventionists capable of radial PCI. We created a hierarchical logistic regression model to identify operator and patient characteristics associated with radial PCI and the median rate ratio to quantify the variation across operators. A subset was interviewed to assess health literacy and preferences in shared medical decision making. Radial access was used in 17.7% of patients. Patient factors associated with lower rate of radial PCI were previous PCI (33.4% vs 41.4%, p = 0.008), history of coronary artery bypass graft (8.4% vs 23.0%, p <0.001), and chronic total occlusion PCI (10.2% vs 17.9%, p <0.001). Operator characteristics associated with lower rate of radial PCI are being older, being longer in practice, lower number of publications, and Southern practice location. The range of radial use across operators was 1% to 99% and the median rate ratio was 1.97. Patients with radial access had lower health literacy, as assessed by the Rapid Estimate of Adult Literacy in Medicine Revised (REALM) score (6.6 ± 2.6 vs 7.1 ± 2.0, p = 0.03) but did not differ in their preferences for shared decision making. In conclusion, our study demonstrates a high degree of variability of radial access for PCI among different operators, with few differences in patient characteristics, suggesting that improvement efforts should focus on operators. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Anomalous Medial Branch of Radial Artery: A Rare Variant

    Directory of Open Access Journals (Sweden)

    Surbhi Wadhwa

    2016-10-01

    Full Text Available Radial artery is an important consistent vessel of the upper limb. It is a useful vascular access site for coronary procedures and its reliable anatomy has resulted in an elevation of radial forearm flaps for reconstructive surgeries of head and neck. Technical failures, in both the procedures, are mainly due to anatomical variations, such as radial loops, ectopic radial arteries or tortuosity in the vessel. We present a rare and a unique anomalous medial branch of the radial artery spiraling around the flexor carpi radialis muscle in the forearm with a high rising superficial palmar branch of radial artery. Developmentally it probably is a remanent of the normal pattern of capillary vessel maintenance and regression. Such a case is of importance for reconstructive surgeons and coronary interventionists, especially in view of its unique medial and deep course.

  2. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia.

    Science.gov (United States)

    Titano, J J; Biederman, D M; Marinelli, B S; Patel, R S; Kim, E; Tabori, N E; Nowakowski, F S; Lookstein, R A; Fischman, A M

    2016-05-01

    Transradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions. Patients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications. From July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6% with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9%) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1%) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups. Transradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  3. Ultrahigh-resolution ultrasound characterization of access site trauma and intimal hyperplasia following use of a 7F sheathless guide versus 6F sheath/guide combination for transradial artery PCI: Results of the PRAGMATIC trial.

    Science.gov (United States)

    Batchelor, Wayne; Dahya, Vishal; McGee, Dan; Katopodis, John; Dixon, William; Campbell, James; Meredith, Ashley; Knap, Patty; Parkin, Mathew; Noel, Thomas

    2018-04-01

    There exist limited data on the relative degree of acute injury and late healing of the radial artery after transradial artery (TRA) percutaneous coronary intervention (PCI) with a 7F sheathless guide catheter compared with a 6F sheath/guide combination. We used ultrahigh-resolution (55 MHz) vascular ultrasound to compare intimal-medial thickening (IMT) and early and late radial artery (RA) injury resulting from a sheathless 7F guide catheter versus a 6F sheath/guide combination for TRA-PCI. Forty-one consecutive consenting patients undergoing elective nonemergent TRA-PCI at a single institution from June 2016 to December 2016 were included. Patients were randomized (stratified by sex) to undergo TRA-PCI using a 7F sheathless guide catheter versus a 6F sheath/6F guide combination. Ultrahigh-resolution vascular ultrasound (55MHz) of the RA access site was performed at 24hours and 90days post-TRA-PCI. The primary outcome of the study was a noninferiority comparison of radial artery IMT thickness at 90days. PCI success rates, fluoroscopy times, number of guides used, and crossover rates to a femoral approach were also compared. Baseline characteristics were similar between groups. Radial arterial IMT (mm) was similar between the 7F sheathless and 6F sheath/guide groups at 24hours (0.27 vs 0.29, respectively; P=.43) and at 90days (0.35 vs 0.34, respectively; P=.96). The P value for the noninferiority testing of a 0.07-mm limit was .002. Limited access site intimal tears were relatively common in both groups at 24hours (4 vs 5, P=.53) but often healed by 90days. Radial artery occlusion was infrequent at 90days (2 vs 1, P=.10), and no frank dissections were noted. PCI success rates (100% vs 95%, P=.59), fluoroscopy times (16 vs 12minutes, P=.17), number of guides used (1.1 vs 1.2, P=.48), and femoral crossover rates (0% vs 0%) were similar between the 2 respective groups. A 7F sheathless approach to TRA-PCI results in no more IMT and early or late RA trauma than a

  4. Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Yaseen, R.; Memon, H.

    2008-01-01

    To assess the effectiveness of femoral and radial arterial lines on the correlation of peripheral and central mean arterial blood pressure in children after discontinuation of cardiopulmonary bypass. Fifty children scheduled for cardiac surgery with cardiopulmonary bypass were included in the study. After approval from the hospital ethics committee and informed consent. 50 children undergoing cardiac surgical procedures with cardiopulmonary bypass were randomly assigned to two different groups. In Group- A (RAP, n-2) a radial arterial line and in Group-B (FAP, n-25) a femoral arterial line was used to monitor the blood pressure. Simultaneous mean peripheral arterial pressure and mean central aortic pressure were recorded before cardiopulmonary bypass and 5 mins after separation from the cardiopulmonary bypass. The correlation of mean peripheral arterial pressure (radial and femoral) versus mean aortic pressure were compared. The data was recorded as Mean +- SD and P-value. The ages of children ranged from 4-12 years and their weight from 14.1-28.5 kg. In all of them following cardiopulmonary bypass, aortic pressure correlates better with femoral arterial pressure (p<0.001). The radial arterial line readings under estimated central aortic pressure when compared to femoral arterial line readings. Aortic pressure readings correlate better with femoral arterial pressure than radial arterial pressure in children. (author)

  5. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

    International Nuclear Information System (INIS)

    Titano, J. J.; Biederman, D. M.; Marinelli, B. S.; Patel, R. S.; Kim, E.; Tabori, N. E.; Nowakowski, F. S.; Lookstein, R. A.; Fischman, A. M.

    2016-01-01

    PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  6. Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

    Energy Technology Data Exchange (ETDEWEB)

    Titano, J. J., E-mail: joseph.titano@mountsinai.org; Biederman, D. M., E-mail: derek.biederman@mountsinai.org; Marinelli, B. S., E-mail: brett.marinelli@exchange.mssm.edu; Patel, R. S., E-mail: rahul.patel@mountsinai.org; Kim, E., E-mail: edward.kim@mountsinai.org; Tabori, N. E., E-mail: nora.tabori@mountsinai.org; Nowakowski, F. S., E-mail: scott.nowakowski@mountsinai.org; Lookstein, R. A., E-mail: robert.lookstein@mountsinai.org; Fischman, A. M., E-mail: aaron.fischman@mountsinai.org [Icahn School of Medicine at Mount Sinai, Department of Interventional Radiology (United States)

    2016-05-15

    PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

  7. Feasibility and Safety of Transradial Arterial Approach for Simultaneous Right and Left Vertebral Artery Angiographic Studies and Stenting

    International Nuclear Information System (INIS)

    Yip, H.-K.; Youssef, Ali A.; Chang, W.-N.; Lu, C.-H.; Yang, C.-H.; Chen, S.-M.; Wu, C.-J.

    2007-01-01

    Objectives. This study investigated whether the transradial artery (TRA) approach using a 6-French (F) Kimny guiding catheter for right vertebral artery (VA) angiographic study and stenting is safe and effective for patients with significant VA stenosis. Background. The TRA approach is commonly performed worldwide for both diagnostic cardiac catheterization and catheter-based coronary intervention. However, to our knowledge, the safety and feasibility of left and right VA angiographic study and stenting, in the same procedure, using the TRA approach for patients with brain ischemia have not been reported. Methods. The study included 24 consecutive patients (22 male, 2 female; age, 63-78 years). Indications for VA angiographic study and stenting were (1) prior stroke or symptoms related to vertebrobasilar ischemia and (2) an asymptomatic but vertebral angiographic finding of severe stenosis (>70%). A combination of the ipsilateral and retrograde-engagement technique, which involved a looping 6-F Kimny guiding catheter, was utilized for VA angiographic study. For VA stenting, an ipsilateral TRA approach with either a Kimny guiding catheter or a left internal mammary artery guiding catheter was utilized in 22 patients and retrograde-engagement technique in 2 patients. Results. A technically successful procedure was achieved in all patients, including left VA stenting in 15 patients and right VA stenting in 9 patients. The mean time for stenting (from engagement to stent deployment) was 12.7 min. There were no vascular complications or mortality. However, one patient suffered from a transient ischemic attack that resolved within 3 h. Conclusion. We conclude that TRA access for both VA angiographic study and VA stenting is safe and effective, and provides a simple and useful clinical tool for patients unsuited for femoral arterial access

  8. Transradial access: lessons learned from cardiology.

    Science.gov (United States)

    Snelling, Brian M; Sur, Samir; Shah, Sumedh Subodh; Marlow, Megan M; Cohen, Mauricio G; Peterson, Eric C

    2018-05-01

    Innovations in interventional cardiology historically predate those in neuro-intervention. As such, studying trends in interventional cardiology can be useful in exploring avenues to optimise neuro-interventional techniques. One such cardiology innovation has been the steady conversion of arterial puncture sites from transfemoral access (TFA) to transradial access (TRA), a paradigm shift supported by safety benefits for patients. While neuro-intervention has unique anatomical challenges, the access itself is identical. As such, examining the extensive cardiology literature on the radial approach has the potential to offer valuable lessons for the neuro-interventionalist audience who may be unfamiliar with this body of work. Therefore, we present here a report, particularly for neuro-interventionalists, regarding the best practices for TRA by reviewing the relevant cardiology literature. We focused our review on the data most relevant to our audience, namely that surrounding the access itself. By reviewing the cardiology literature on metrics such as safety profiles, cost and patient satisfaction differences between TFA and TRA, as well as examining the technical nuances of the procedure and post-procedural care, we hope to give physicians treating complex cerebrovascular disease a broader data-driven understanding of TRA. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  9. Endoscopic Radial Artery Harvest for Coronary Artery Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Kuan-Ming Chiu

    2006-01-01

    Conclusion: Endoscopic harvest of the radial artery is technically demanding, but excellent results can be achieved. The endoscopic approach can provide suitable conduits in a less invasive way than the open harvest technique.

  10. Rare high origin of the radial artery: a bilateral, symmetrical case ...

    African Journals Online (AJOL)

    Arterial variations in the upper limb can occur at the level of the axillary, brachial, radial and ulnar arteries as well as the palmar arches. This is a report of bilateral, symmetrical high origin of the radial artery from the axillary artery. Knowledge of such variations is important in vascular and reconstructive surgery. (Nig J Surg ...

  11. Endoscopic versus open radial artery harvest and mammario-radial versus aorto-radial grafting in patients undergoing coronary artery bypass surgery

    DEFF Research Database (Denmark)

    Carranza, Christian L; Ballegaard, Martin; Werner, Mads U

    2014-01-01

    the postoperative complications will be registered, and we will evaluate muscular function, scar appearance, vascular supply to the hand, and the graft patency including the patency of the central radial artery anastomosis. A patency evaluation by multi-slice computer tomography will be done at one year...... to aorto-radial revascularisation techniques but this objective is exploratory. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01848886.Danish Ethics committee number: H-3-2012-116.Danish Data Protection Agency: 2007-58-0015/jr.n:30-0838....

  12. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  13. Long-term outcomes of internal carotid artery disease treated using radial artery graft

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Umeoka, Katsuya; Tateyama, Kojiro

    2009-01-01

    Complex internal carotid artery disease presents a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict occurrence of ischemic complications after internal carotid artery ligation. The present study concerns long-term clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2007, we performed radial artery grafting followed immediately by parent artery occlusion in 20 sides of 19 patients with complex internal carotid arteries disease with follow-up for more than 36 months (5 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative MRI and MR angiography (MRA) every year to assess graft patency, ischemic complications, and de novo aneurysm. Another 20 carotid aneurysms with visual disturbance were assessed concerning outcome. Among 13 patients with cranial nerve (III and VI) disturbances, all dysfunctions were improved in cases treated within 8 months of onset to operation. On the other hand, patients with second cranial nerve disturbances were not improved in cases treated after 4 months of onset. No long-term complications were discovered with MRI and MRA. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Long-term safety is satisfactory, with no delayed complications such as graft stenosis, ischemic complications or de novo aneurysm formations in follow-up periods of more than 3 years. Good clinical outcome of cranial nerve palsy was achieved in patients treated within 8 months of onset for cranial nerve (CN) III and VI, and 4 of CN II palsy. (author)

  14. Utility of the puncture of the radial artery in interventionist radiology

    International Nuclear Information System (INIS)

    Triana Rodriguez, Carlos Eduardo; Montes S, Mauricio; Barragan F, Jaime; Ucros Diaz Pablo; Ucros Diaz, Ignacio; Castillo, Luis Fernando

    1998-01-01

    We present the radial artery access, previous evaluation of collateral circulation with Allen's Test, as an alternative vascular access in patients with contraindications for femoral or axillary approaches. The radial artery puncture offers advantages, such as diminished bleeding and hematoma formation

  15. Radial artery anomalies in patients undergoing transradial coronary procedures – An Egyptian multicenter experience

    Directory of Open Access Journals (Sweden)

    Ayman K.M. Hassan

    2016-03-01

    Conclusion: There is a relatively significant presence of radial anomalies, with different degrees of impact on procedural failure rate, in our Egyptian population. Further collaborative studies are recommended to increase our success rates.

  16. Compare Complication of Classic versus Patent Hemostasis in Transradial Coronary Angiography

    OpenAIRE

    Roghani, Farshad; Tajik, Mohammad Nasim; Khosravi, Alireza

    2017-01-01

    Background: Coronary artery disease (CAD) is multifactorial disease, in which thrombotic occlusion and calcification occur usually. New strategies have been made for diagnosis and treatment of CAD, such as transradial catheterization. Hemostasis could be done in two approaches: traditional and patent. Our aim is to find the best approach with lowest complication. Materials and Methods: In a comparative study, 120 patients were recruited and divided randomly into two subgroups, including tradi...

  17. Aneurisma idiopático de artéria radial: relato de caso Idiopathic radial artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    Luiz Ernani Meira Jr.

    2011-12-01

    Full Text Available Os aneurismas da artéria radial são extremamente raros. Em sua maioria, consistem de pseudoaneurismas pós-traumáticos. Os aneurismas da artéria radial verdadeiros podem ser idiopáticos, congênitos, pós-estenóticos ou associados a patologias, tais como vasculites e doenças do tecido conjuntivo. Foi relatado um caso de aneurisma idiopático de artéria radial em uma criança de três anos, que, após completa investigação diagnóstica complementar, foi submetida à ressecção cirúrgica.Radial artery aneurysms are extremely rare. Post-traumatic pseudoaneurysms are the vast majority. True radial artery aneurysms can be idiopathic, congenital, poststenotic, or associated with some pathologies, such as vasculitis and conjunctive tissue diseases. We report a case of an idiopathic aneurysm of the radial artery in a three-year-old child who was submitted to surgical resection after a complete diagnostic approach.

  18. Erosion of Embolization Coils into the Renal Collecting System: Removal with Prone Transradial Renal Arteriography and Nephroscopy.

    Science.gov (United States)

    Srinivasa, Ravi N; Chick, Jeffrey Forris Beecham; Hage, Anthony; Ramamurthi, Aishu; Wolf, J Stuart; Gemmete, Joseph J; Dauw, Casey A

    2017-10-01

    Removal of embolization coils eroded into the renal collecting system poses a risk of hemorrhage, which may need to be addressed with arteriography and embolization at the time of treatment. The purpose of this report is to describe a novel approach, by which prone percutaneous nephroscopic coil retrieval is coupled with simultaneous prone transradial renal arterial access to mitigate this potential complication. A retrospective chart review of the electronic medical record systems was performed from January 2008 to May 2017 to identify patients who had undergone percutaneous removal of embolization coils eroded into the renal collecting system. Patients who had migration of embolization coils into the renal collecting system who were symptomatic with pain, hydronephrosis, or infection were considered for inclusion. Patients who had coil migration, but were asymptomatic were not offered removal. Patient demographics and case characteristics were examined as were operative outcomes. A total of three patients fulfilled the study criteria. Migrated embolization coils were able to be effectively removed in all patients. Of the patients, two underwent simultaneous prone transradial renal arteriography with placement of an occlusion balloon catheter into the segmental artery of interest. In one patient, significant arterial bleeding was encountered after coil removal, which was effectively addressed with simultaneous arteriography and glue embolization. Erosion of embolization coils into the renal collecting system, while rare, may be a significant long-term complication of coil embolization. Combining nephroscopy with prone transradial arteriography in preparation for procedure-associated hemorrhage may make removal of migrated coils safer.

  19. Usefulness and safety of a guide catheter extension system for the percutaneous treatment of complex coronary lesions by a transradial approach.

    Science.gov (United States)

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2015-01-01

    The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive procedures (in 15 patients; 12 males and 3 females) were evaluated. The indication for the use of GuideLiner was a difficulty to advance and properly position a stent through a tortuous and/or calcified artery despite using high-support guide catheters or other useful techniques. Of the 16 angiographic procedures, 14 (87.5%) were successful (stent deployment in 13 cases and a drug-eluting balloon in 1 case). Unsuccessful cases were a chronic total occlusion and a diffusely diseased left anterior descendant artery. A type B dissection of a proximal left circumflex artery was the only periprocedural complication. Use of the GuideLiner was an effective and safe technique for the percutaneous treatment of complex coronary lesions in which the adequate progress of angioplasty devices had failed. GuideLiner was particularly helpful when using the transradial approach. Only one minor complication was recorded. © 2014 S. Karger AG, Basel.

  20. Evaluation of anatomy and variations of superficial palmar arch and upper extremity arteries with CT angiography.

    Science.gov (United States)

    Kaplanoglu, Hatice; Beton, Osman

    2017-04-01

    To evaluate the abnormalities and variations of the arterial system of upper extremities and superficial palmar arch with computed tomography angiography and to guide the clinician during this procedure. A total of 156 upper extremities of 78 cases were retrospectively analyzed using computed tomography angiography. The study was approved by the local ethics committee of the hospital. From the analysis of the computed tomography angiography images, the following information was recorded; the diameters and abnormalities of radial, ulnar and brachial arteries in both upper extremities, the presence of atherosclerotic changes or stenosis in these arteries, whether the superficial palmar arch was complete or incomplete, and arterial dominance. Also, the computed tomography angiography classification of superficial palmar arch distribution and anatomic configuration was performed. The mean baseline diameters of the radial, ulnar and brachial arteries of the cases were; 2.8 ± 0.6, 2.5 ± 0.7, and 4.7 ± 0.6 mm, respectively. A complete superficial palmar arch was observed in 69.2 % of the right hands and 70.5 % of the left hands. For the superficial palmar arches on the right side, the radial artery was dominant in two and the ulnar artery was dominant in 47 with the remaining showing codominance. On the left side, the radial artery was dominant in one hand, with the ulnar artery being dominant in 49 cases, and in 28 cases, there was codominance. In the superficial palmar arch classification, four of the arches (A-D) were defined as complete and the remaining three (E-G) as incomplete. The current study clarified different variations in palmar circulation and forearm arteries to aid the surgeon during trans-radial or trans-ulnar catheterization, hemodialysis, or coronary artery bypass grafting.

  1. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  2. High Origin of Radial Arteries: A Report of Two Rare Cases

    Directory of Open Access Journals (Sweden)

    Dong Zhan

    2010-01-01

    Full Text Available Variations in the arterial supply of the upper limb are relatively common, with reported prevalence rates ranging from 11 to 24.4%. Of these, the most commonly encountered variation in the arm is a high origin of the radial artery. However, after consecutively dissecting and examining 600 Singaporean Chinese cadavers (1,200 upper limbs, we found only two cases of this. In both cases, the brachioradial artery originated from the upper one-third of the brachial artery and continued distally as the radial artery in the forearm. The local prevalence of 0.33% of this variation is significantly lower compared against populations from other geographical regions. Although rare, recognition of the variation is of fundamental importance to clinical practice.

  3. Optimal management of radial artery grafts in CABG: Patient and target vessel selection and anti-spasm therapy.

    Science.gov (United States)

    Schwann, Thomas A; Gaudino, Mario; Baldawi, Mustafa; Tranbaugh, Robert; Schwann, Alexandra N; Habib, Robert H

    2018-05-01

    The current literature on radial artery grafting is reviewed focusing on the optimal deployment of radial artery grafts in coronary artery bypass surgery with specific attention to the selection of patients and target vessels for radial artery grafting. © 2018 Wiley Periodicals, Inc.

  4. Ulnar artery: The Ulysses ultimate resort for coronary procedures

    Directory of Open Access Journals (Sweden)

    George Hahalis, MD, PhD

    2016-07-01

    Full Text Available Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA. Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates.

  5. Analysis of linguistic terms of variables representing the wave of arterial diameter variation in radial arteries using fuzzy entropies

    International Nuclear Information System (INIS)

    Nuno Almirantearena, F; Introzzi, A; Clara, F; Burillo Lopez, P

    2007-01-01

    In this work we use 53 Arterial Diameter Variation (ADV) waves extracted from radial artery of normotense males, along with the values of variables that represent the ADV wave, obtained by means of multivariate analysis. Then, we specify the linguistic variables and the linguistic terms. The variables are fuzzified using triangular and trapezoidal fuzzy numbers. We analyze the fuzziness of the linguistic terms by applying discrete and continuous fuzzy entropies. Finally, we infer which variable presents the greatest disorder associated to the loss of arterial elasticity in radial artery

  6. Pseudoaneurysm of the Radial Artery After a Bicycle Fall.

    Science.gov (United States)

    Ratschiller, Thomas; Müller, Hannes; Schachner, Thomas; Zierer, Andreas

    2018-07-01

    We report a case of a 64-year-old man who developed a painful pulsatile mass in the distal forearm after a bicycle fall with fracture of the wrist. Ultrasonography confirmed a 2.5-cm large pseudoaneurysm of the radial artery. The patient underwent surgical exploration. The pseudoaneurysm was resected and the defect in the arterial wall was reconstructed with an autologous saphenous vein patch. We suggest that the double arterial supply of the hand should be preserved whenever possible.

  7. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  8. Ulnar artery: The Ulysses ultimate resort for coronary procedures.

    Science.gov (United States)

    Hahalis, George; Deftereos, Spyridon; Bertrand, Olivier F

    2016-08-20

    Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA) only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA). Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO) rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates. Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  9. Radial motion of the carotid artery wall: A block matching algorithm approach

    Directory of Open Access Journals (Sweden)

    Effat Soleimani

    2012-06-01

    Full Text Available Introduction: During recent years, evaluating the relation between mechanical properties of the arterialwall and cardiovascular diseases has been of great importance. On the other hand, motion estimation of thearterial wall using a sequence of noninvasive ultrasonic images and convenient processing methods mightprovide useful information related to biomechanical indexes and elastic properties of the arteries and assistdoctors to discriminate between healthy and diseased arteries. In the present study, a block matching basedalgorithm was introduced to extract radial motion of the carotid artery wall during cardiac cycles.Materials and Methods: The program was implemented to the consecutive ultrasonic images of thecommon carotid artery of 10 healthy men and maximum and mean radial movement of the posterior wall ofthe artery was extracted. Manual measurements were carried out to validate the automatic method andresults of two methods were compared.Results: Paired t-test analysis showed no significant differences between the automatic and manualmethods (P>0.05. There was significant correlation between the changes in the instantaneous radialmovement of the common carotid artery measured with the manual and automatic methods (withcorrelation coefficient 0.935 and P<0.05.Conclusion: Results of the present study showed that by using a semi automated computer analysismethod, with minimizing the user interfere and no attention to the user experience or skill, arterial wallmotion in the radial direction can be extracted from consecutive ultrasonic frames

  10. Transradial PCI and Same Day Discharge.

    Science.gov (United States)

    Elfandi, Ali; Safirstein, Jordan G

    2018-02-24

    The evolution of cardiac catheterization has led to the development of well-refined, more effective, and safer devices that allow cardiovascular interventionalists to deliver high-quality percutaneous interventions (PCI). Transradial PCI (TRI) has gained more popularity in the USA over the past 10 years, and as experience and volume of TRI grow, studies adopting same day radial PCI protocols have emerged and are showing promising results. We sought to review the current literature on TRI and same day discharge (SDD). This literature review was performed to evaluate the studies that were published over the last 17 years regarding TRI and SDD. A literature search using PubMed, Cochran database, Google Scholar, and Embase was performed for studies evaluating TRI and SDD from January 1, 2000, to August 1, 2017. Observational studies, randomized clinical trials, meta-analyses, and consensus statements were included in our review. We used the following terms in our search: "same day," "same day discharge," "outpatient," and "ambulatory radial PCI." Articles with data pertinent to the subject matter were included. We did not limit our searches to specific journals. The available literature supports SDD for selected radial PCI patients. The advancement in PCI devices and pharmacology has enhanced the safety of post-PCI disposition leading to the evolution from traditional overnight stays to the development of same day discharge programs. We conclude that outpatient TRI for appropriately selected patients will be the standard of care in the future. This will lead to increased patient satisfaction, improved hospital throughput, and reduced hospital costs, without increased procedural complications.

  11. Compare Complication of Classic versus Patent Hemostasis in Transradial Coronary Angiography.

    Science.gov (United States)

    Roghani, Farshad; Tajik, Mohammad Nasim; Khosravi, Alireza

    2017-01-01

    Coronary artery disease (CAD) is multifactorial disease, in which thrombotic occlusion and calcification occur usually. New strategies have been made for diagnosis and treatment of CAD, such as transradial catheterization. Hemostasis could be done in two approaches: traditional and patent. Our aim is to find the best approach with lowest complication. In a comparative study, 120 patients were recruited and divided randomly into two subgroups, including traditional group (60 patients; 24 females, 36 males; mean age: 64.35 ± 10.56 years) and patent group (60 patients; 28 females, 32 males; mean age: 60.15 ± 8.92 years). All demographic data including age, gender, body mass index, and CAD-related risk factors (smoking, diabetes, hypertension) and technical data including the number of catheters, procedure duration, and hemostatic compression time and clinical outcomes (radial artery occlusion [RAO], hematoma, bleeding) were collected. Data were analyzed by SPSS version 16. Our findings revealed that the incidence of RAO was significantly lower in patent groups compared with traditional group ( P = 0.041). Furthermore, the difference incidence of RAO was higher in early occlusion compare with late one ( P = 0.041). Moreover, there were significant relationship between some factors in patients of traditional group with occlusion (gender [ P = 0.038], age [ P = 0.031], diabetes mellitus [ P = 0.043], hemostatic compression time [ P = 0.036]) as well as in patent group (age [ P = 0.009], hypertension [ P = 0.035]). Our findings showed that RAO, especially type early is significantly lower in patent method compared classic method; and patent hemostasis is the safest method and good alternative for classical method.

  12. Compare Complication of Classic versus Patent Hemostasis in Transradial Coronary Angiography

    Directory of Open Access Journals (Sweden)

    Farshad Roghani

    2017-01-01

    Full Text Available Background: Coronary artery disease (CAD is multifactorial disease, in which thrombotic occlusion and calcification occur usually. New strategies have been made for diagnosis and treatment of CAD, such as transradial catheterization. Hemostasis could be done in two approaches: traditional and patent. Our aim is to find the best approach with lowest complication. Materials and Methods: In a comparative study, 120 patients were recruited and divided randomly into two subgroups, including traditional group (60 patients; 24 females, 36 males; mean age: 64.35 ± 10.56 years and patent group (60 patients; 28 females, 32 males; mean age: 60.15 ± 8.92 years. All demographic data including age, gender, body mass index, and CAD-related risk factors (smoking, diabetes, hypertension and technical data including the number of catheters, procedure duration, and hemostatic compression time and clinical outcomes (radial artery occlusion [RAO], hematoma, bleeding were collected. Data were analyzed by SPSS version 16. Results: Our findings revealed that the incidence of RAO was significantly lower in patent groups compared with traditional group (P = 0.041. Furthermore, the difference incidence of RAO was higher in early occlusion compare with late one (P = 0.041. Moreover, there were significant relationship between some factors in patients of traditional group with occlusion (gender [P = 0.038], age [P = 0.031], diabetes mellitus [P = 0.043], hemostatic compression time [P = 0.036] as well as in patent group (age [P = 0.009], hypertension [P = 0.035]. Conclusion: Our findings showed that RAO, especially type early is significantly lower in patent method compared classic method; and patent hemostasis is the safest method and good alternative for classical method.

  13. A novel compliance measurement in radial arteries using strain-gauge plethysmography

    International Nuclear Information System (INIS)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-01-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C strain ) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29–85 were compared with 14 normotensive patients aged 25–62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005)

  14. A novel compliance measurement in radial arteries using strain-gauge plethysmography.

    Science.gov (United States)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-09-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the Z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C(strain)) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29-85 were compared with 14 normotensive patients aged 25-62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005).

  15. Operator radiation exposure during right or left transradial coronary angiography: A phantom study

    International Nuclear Information System (INIS)

    Sciahbasi, Alessandro; Rigattieri, Stefano; Sarandrea, Alessandro; Cera, Maria; Di Russo, Cristian; Fedele, Silvio; Romano, Silvio; Pugliese, Francesco Rocco; Penco, Maria

    2015-01-01

    Background: Previous studies showed a possible lower radiation dose absorbed by operators comparing LRA and RRA for percutaneous coronary procedures. The reasons of this lower radiation dose are not well known. The aim of this study was to evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) during a simulated diagnostic coronary angiography using a phantom. Methods: A coronary angiography examination was simulated on a phantom by 5 operators using eight projections with 5 seconds fluoroscopy each. Each operator was equipped with 4 electronic dosimeters placed at thorax, at left wrist, at left head and at hip level. Radiation doses were expressed in picosievert and normalized by dose area product. Results: LRA compared to RRA was associated with a significant lower operator dose at wrist (36 pSv/cGYcm"2 [IQR 18–59 pSv/cGYcm"2] and 48 pSv/cGYcm"2 [IQR 22–148 pSv/cGYcm"2] respectively, p = 0.01) and thorax (3 pSv/cGYcm"2 [IQR 2–5 pSv/cGYcm"2] and 10 pSv/cGYcm"2 [6–23 pSv/cGYcm"2] respectively, p < 0.001) but with a significant higher radiation dose at hip level (102 pSv/cGYcm"2 [IQR 44–199 pSv/cGYcm"2] and 67 pSv/cGYcm"2 [IQR 39–132 pSv/cGYcm"2] respectively, p = 0.02). Conversely the radiation dose at left side of the head did not show significant differences between the two approaches. Conclusions: In this phantom study simulating a diagnostic coronarography the use of LRA compared to RRA was associated with a significant lower radiation dose at wrist and thorax but with an increased dose at hip level. Summary: To evaluate the radiation dose absorbed by operators comparing left with right radial access (LRA and RRA respectively) we simulated a diagnostic coronary angiography using a dedicated phantom. Operators were equipped with dedicated electronic dosimeters at wrist, hip, head and thorax level. LRA compared to RRA was associated with a significant lower operator dose at wrist and thorax

  16. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University, Department of Radiology, School of Medicine (Turkey); Güney, Bünyamin [Muğla Sıtkı Kocman University, Department of Radiology, School of Medicine (Turkey)

    2016-09-15

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  17. Utilização da artéria radial como segundo enxerto arterial em pacientes acima de 70 anos The use of the radial artery as the second choice for arterial graft in patients over 70 years of age

    Directory of Open Access Journals (Sweden)

    Joseph Fredric Whitaker

    2005-03-01

    Full Text Available OBJETIVO: Estudo retrospectivo para avaliar a morbi-mortalidade e a evolução hospitalar em pacientes com idade superior a 70 anos, submetidos à operação de revascularização do miocárdio com utilização da artéria radial como segundo enxerto arterial. MÉTODO: No período de agosto de 1994 a dezembro de 2002, foram realizadas 2487 cirurgias de revascularização do miocárdio no Instituto do Coração de Juiz de Fora. Dentre os pacientes operados, 476 tinham idade superior a 70 anos, sendo que em 36 (Grupo II foi utilizada a artéria radial como 2º enxerto arterial. O mesmo tipo de cirurgia foi realizado em 142 pacientes com idade inferior a 70 anos (Grupo I. Não foram incluídas neste estudo reoperações, cirurgias sem CEC ou com procedimentos associados. RESULTADOS: A média de idade do Grupo II foi 72,5 anos, a mortalidade hospitalar neste grupo de pacientes foi 6,0%, a incidência de complicações também foi baixa, comparável à observada no mesmo tipo de operação realizada em pacientes com idade inferior a 70 anos. CONCLUSÃO: Diante destes resultados, os autores acreditam que a artéria radial possa ser usada com segurança como 2º enxerto arterial em pacientes acima de 70 anos, criteriosamente selecionados, apesar do maior risco de co-morbidades associadas nesta faixa etária.OBJECTIVE: Retrospective study eveluating the morbid-mortality and hospital behaviour in patients over 70-years -od patients submitted to myocardial revascularization involving the radial artery as the second arterial graft. METHOD: During the period of August 1994 to December 2002, 2487 cases of myocardial revascularization were performed by the group of the Juiz de Fora Heart Institute, 476 of whom were 70 years of age or older and 36 (Group II received the radial artery as the second arterial graft. The same type of surgery was performed in 142 patients under 70-year-old (Group I. Reoperations, off-pump operations (OPCAB or associated procedures

  18. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  19. Use of orbital atherectomy in acute myocardial infarction via the transradial approach

    Science.gov (United States)

    Mowakeaa, Samer; Snyder, Branden; Kakouros, Nikolaos

    2016-01-01

    Severe coronary artery calcifications pose an ongoing challenge when performing percutaneous coronary interventions, resulting in an increased likelihood of procedural complications. Orbital atherectomy (OA) has emerged as a promising technology that helps improve outcomes in this complex patient population. Its safety and efficacy are yet to be demonstrated in the setting of acute myocardial infarction. We present a case of a patient with acute ST-elevation myocardial infarction (STEMI) evaluated with emergent transradial coronary angiography. The culprit lesion was a severely stenotic, heavily calcified, segment of the right coronary artery. The use of OA facilitated lesion expansion and implantation of a drug-eluting stent. Although OA should be considered as contraindicated for the management of soft-ruptured plaque, which accounts for the majority of STEMI presentations, it may be well applied to the small subset of patients with calcified nodule pathology, even in the acute setting. PMID:28180008

  20. Complications and nursing care in interventional treatment of diabetic foot via radial artery access

    International Nuclear Information System (INIS)

    Liu Lingyun; Zhou Xiaoxiang; Zeng Yongmei; Chen Junfei; Lai Lisha; Pang Pengfei; Zhu Kangshun

    2009-01-01

    Objective: To evaluate the therapeutic effect of interventional treatment via radial artery access for diabetic foot and to summarize its complications and nursing care. Methods: The interventional treatment via radial artery access was performed in twenty patients with diabetic foot. The preoperative psychological nursing care, the nursing of the punctured site of radial artery and the indwelling catheter, the complications of the puncture site and thrombolytic therapy were reviewed and retrospectively analyzed. Results: Some complications occurred in eight cases, including hematoma at puncture site (n= 1), oozing of blood (n=3), gingival bleeding (n=1) and pain (n=3). No retention of urine or infection occurred. Conclusion: It is very important to pay enough attention to the nursing care of puncture site and indwelling catheter sheath and to make a close observation of patient's condition in order to reduce the occurrence of complications. Rich clinical experience and careful observation after the operation can definitely reduce the occurrence of thrombolytic complications and improve the patient's living quality. (authors)

  1. Evaluación de hipertensos en base a registros de variación de diámetro arterial radial Evaluation of hypertensive patients by radial arterial diameter variation recording

    Directory of Open Access Journals (Sweden)

    Fernando M. Clara

    2006-12-01

    Full Text Available Se utilizó la técnica de análisis del registro incruento de las variaciones de diámetro de arteria radial para evaluar el deterioro arterial y el riesgo cardiovascular en pacientes hipertensos. El transductor utilizado consistió en un sensor de movimiento apoyado sobre la zona de palpación del pulso radial. Se efectuó la determinación del índice de aumentación radial, un parámetro que cuantifica la magnitud de las reflexiones de la onda de presión en la región aórtica, sobre un conjunto de 47 hipertensos, y se lo comparó con otro estudio similar efectuado sobre 81 normotensos sanos. Estos últimos presentaron menores valores de dicho índice, pero al avanzar la edad los valores de ambos grupos tendieron a coincidir. Esto fue confirmado al comparar morfológicamente los registros de ambos grupos, hallándose que los registros de ancianos normotensos sanos e hipertensos de edades similares resultaron visiblemente parecidos. Se halló también que determinados hipertensos jóvenes presentaron ciertas características morfológicas similares a las de normotensos de la misma edad, indicando que aún conservaban las características elásticas propias de su grupo etario. Los resultados fueron similares a los logrados sobre registros de presión arterial radial obtenidos mediante tonometría de aplanación, utilizándose una tecnología disponible en nuestro medio y de menor costo.A blood less analysis technique of the diameter variation signal at radial artery was used to evaluate the arterial disease and the cardiovascular risk in hypertensive patients. A movement transducer was used to record the wrist pulse. A radial augmentation index was proposed to quantify the magnitude of the pressure wave reflections in the aortic region. The experiment was carried out with a group of 47 hypertensive men and compared with a similar study performed on 81 normotensive healthy men. The last ones presented smaller values of this index, but as age

  2. Vasodilatory effect and endothelial integrity in papaverine- and milrinone-treated human radial arteries.

    Science.gov (United States)

    Rudzinski, P; Wegrzyn, P; Lis, G J; Piatek, J; Konstanty-Kalandyk, J; Nosalski, R; Mikolajczyk, T; Jasinska, M; Pyka-Fosciak, G; Guzik, T; Litwin, J A; Korbut, R; Sadowski, J

    2013-02-01

    Prevention of the vasospasm is an important aspect of coronary artery bypass grafting (CABG) with the use of radial artery (RA) as the conduit. We compared the effect of two phosphodiesterase inhibitors papaverine and milrinone on vasodilation and endothelial integrity of human RA segments harvested from 20 CABG patients. Vasodilatory effect of the drugs were assessed by organ bath technique in RA rings precontracted with KCl and phenylephrine. Endothelial integrity was evaluated by CD34 immunofluorescence in frozen sections. Vasorelaxation induced by papaverine was significantly greater as compared to that induced by milrinone (90.47% ± 10.16% vs. 78.98% ± 19.56%, pmilrinone in the preservation of endothelial integrity (75.3% ± 12.9% vs. 51.8% ± 18.0%, pmilrinone for prevention of vasospasm in radial artery conduits used for CABG.

  3. Golf hand prosthesis performance of transradial amputees.

    Science.gov (United States)

    Carey, Stephanie L; Wernke, Matthew M; Lura, Derek J; Kahle, Jason T; Dubey, Rajiv V; Highsmith, M Jason

    2015-06-01

    Typical upper limb prostheses may limit sports participation; therefore, specialized terminal devices are often needed. The purpose of this study was to evaluate the ability of transradial amputees to play golf using a specialized terminal device. Club head speed, X-factor, and elbow motion of two individuals with transradial amputations using an Eagle Golf terminal device were compared to a non-amputee during a golf swing. Measurements were collected pre/post training with various stances and grips. Both prosthesis users preferred a right-handed stance initially; however, after training, one preferred a left-handed stance. The amputees had slower club head speeds and a lower X-factor compared to the non-amputee golfer, but increased their individual elbow motion on the prosthetic side after training. Amputees enjoyed using the device, and it may provide kinematic benefits indicated by the increase in elbow flexion on the prosthetic side. The transradial amputees were able to swing a golf club with sufficient repetition, form, and velocity to play golf recreationally. Increased elbow flexion on the prosthetic side suggests a potential benefit from using the Eagle Golf terminal device. Participating in recreational sports can increase amputees' health and quality of life. © The International Society for Prosthetics and Orthotics 2014.

  4. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    Directory of Open Access Journals (Sweden)

    Min-Ho Jun

    2016-05-01

    Full Text Available The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

  5. [Digital necrosis in a patient with anorexia nervosa. Association of vasculopathy and radial artery injury].

    Science.gov (United States)

    Launay, D; Queyrel, V; Hatron, P Y; Michon-Pasturel, U; Hachulla, E; Devulder, B

    2000-11-13

    Patients with anorexia nervosa can develop distal vasculopathy sometimes leading to severe Raynaud's phenomenon or acrocyanosis. We report a cas of anorexia nervosa-related vasculopathy associated with iatrogenic injury to the radial artery that led to digital necrosis. An 18-year-old woman, with a history of severe anorexia nervosa of 5 years duration and who acknowledged regular use of tobacco and cannabis, was hospitalized for necrosis of the left index and thumb that had occurred shortly after left radial artery puncture for blood gas analysis. Acrocyanosis of the 4 limbs had been present since the onset of anorexia nervosa. Arteriography of the upper limbs showed major spasm of the left radial and cubital arteries and thromboses in the left interdigital arteries of the left index and thumb. The distal portions of the arteries were then on the left and on the right. The nectrotic lesions healed after intravenous administration of ilomedine and interruption of tobacco and cannabis. Acrocyanosis of the four limbs persisted. We report a case of digital necrosis occurring after arterial puncture for blood gas analysis in a patient with a vascular bed weakened by tobacco and cannabis intoxication but also by anorexia nervosa-related vasculopathy. This observation underlines the potentially dangerous nature of invasive intravascular procedures in this context. Indications for vessel puncture must be assessed with prudence.

  6. Reliability of palpation of the radial artery compared with auscultation of the brachial artery in measuring SBP

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; van den Born, Bert-Jan H.; van Montfrans, Gert A.

    2011-01-01

    Background Systolic blood pressure contributes more to cardiovascular disease than DBP, especially in elderly persons. Palpation of the radial artery to assess SBP - Riva-Rocci's technique-may be an attractive alternative for auscultatory SBP in these patients. Therefore, we investigated the

  7. Femoral Access PCI in a Default Radial Center Identifies High-Risk Patients With Poor Outcomes.

    Science.gov (United States)

    Uddin, Muezz; Bundhoo, Shantu; Mitra, Rito; Ossei-Gerning, Nicholas; Morris, Keith; Anderson, Richard; Kinnaird, Tim

    2015-10-01

    Increasingly the trans-radial route (TRR) is preferred over the trans-femoral route (TFR) for PCI. However, even in high volume default TRR centers a cohort of patients undergo TFR PCI. We examined the demographics, procedural characteristics, and outcomes of patients undergoing PCI via the TF. The patient demographics, procedural data, and outcomes of 5,379 consecutive patients undergoing PCI at a default radial center between 2009 and 2012 were examined. Major bleeding (MB) was classified by ACUITY and BARC definitions. A total of 559 (10.4%) patients underwent PCI via the TFR and 4,820 patients via the TRR (89.6%). Baseline variables associated with TFR were shock, previous CABG, chronic total occlusion intervention, rotablation/laser use, female sex, and renal failure. Sixty-five patients of the TFR cohort (11.6%) experienced MB with 27 (41.5%) being access site related. MB was significantly more frequent than in the radial cohort. The variables independently associated with MB in the TFR cohort were renal failure, acute presentation, shock, and age. In the TFR, patients with MB mortality was high at 30 days (17.2% vs 2.6% for no MB, P default radial PCI center 10% of patients undergo PCI via the femoral artery. These patients have high baseline bleeding risk and undergo complex interventions. As a result the incidence of major bleeding, transfusion and death are high. Alternative strategies are required to optimize outcomes in this select group. © 2015, Wiley Periodicals, Inc.

  8. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    OpenAIRE

    Jun, Min-Ho; Kim, Young-Min; Bae, Jang-Han; Jung, Chang Jin; Cho, Jung-Hee; Jeon, Young Ju

    2016-01-01

    The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the s...

  9. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gunja, Ateka; Pandey, Yagya [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Xie, Hui [Division of Epidemiology and Biostatistics, University of Illinois at Chicago, Chicago, IL (United States); Faculty of Health Sciences, Simon Fraser University, Burnaby, BC (Canada); Wolska, Beata M. [Department of Physiology and Biophysics, Center for Cardiovascular Research, University of Illinois at Chicago, Chicago, IL (United States); Shroff, Adhir R.; Ardati, Amer K. [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States)

    2017-04-15

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm{sup 2}). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm{sup 2} ± 74.0 vs. 41.9 mGy cm{sup 2} ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image

  10. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Gunja, Ateka; Pandey, Yagya; Xie, Hui; Wolska, Beata M.; Shroff, Adhir R.; Ardati, Amer K.; Vidovich, Mladen I.

    2017-01-01

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm"2). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm"2 ± 74.0 vs. 41.9 mGy cm"2 ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise compared to

  11. Fractal and twin SVM-based handgrip recognition for healthy subjects and trans-radial amputees using myoelectric signal.

    Science.gov (United States)

    Arjunan, Sridhar Poosapadi; Kumar, Dinesh Kant; Jayadeva J

    2016-02-01

    Identifying functional handgrip patterns using surface electromygram (sEMG) signal recorded from amputee residual muscle is required for controlling the myoelectric prosthetic hand. In this study, we have computed the signal fractal dimension (FD) and maximum fractal length (MFL) during different grip patterns performed by healthy and transradial amputee subjects. The FD and MFL of the sEMG, referred to as the fractal features, were classified using twin support vector machines (TSVM) to recognize the handgrips. TSVM requires fewer support vectors, is suitable for data sets with unbalanced distributions, and can simultaneously be trained for improving both sensitivity and specificity. When compared with other methods, this technique resulted in improved grip recognition accuracy, sensitivity, and specificity, and this improvement was significant (κ=0.91).

  12. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  13. Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access

    International Nuclear Information System (INIS)

    Geijer, Haakan; Persliden, Jan

    2004-01-01

    The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also responded to a questionnaire concerning discomfort and pain during and after the procedure. The mean DAP was 69.8 Gy cm 2 using femoral access and 70.5 Gy cm 2 using radial access. Separating the access site from confounding factors with a multiple regression, there was a 13% reduction in DAP when using radial access (p=0.038). Procedure times did not differ (p=0.81). Bed confinement was much longer in the femoral access group (448 vs 76 min, p=0.000). With femoral access, there was a significantly higher patient grading for chest (p=0.001) and back pain (p=0.003) during the procedure and for access site (p=0.000) and back pain (p=0.000) after the procedure. Thirty-two femoral access patients (28%) were given morphine-type analgesics in the post-procedure period compared to three radial access patients (5%, p=0.001). DAP does not increase when using radial instead of femoral access and the patients grade discomfort and pain much lower when using radial access. Radial access is thus beneficial to use. (orig.)

  14. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  15. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  16. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    Science.gov (United States)

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  17. Lack of tolerance of headache and radial artery diameter during a 7 hour intravenous infusion of nitroglycerin

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Tfelt-Hansen, P

    1993-01-01

    . The intensity of the headache was mild to medium (median headache score 3, range 1-7). The mean dilatation of the radial artery was 36%. The dilatation in each individual, was stable over time, both during NTG and placebo, and it did not change with the double infusion rate. The headache score in each......Nitroglycerin-(NTG)-induced headache and dilatation of the radial artery were followed in a double blind, randomized, placebo-controlled, cross-over study in 6 healthy volunteers. NTG 0.5 microgram.kg-1 x min-1 or saline were infused i.v. for 7 h, and subsequently the infusion rate was doubled...... individual was more fluctuant. No tolerance either to the NTG-induced headache or arterial dilatation was observed....

  18. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  19. Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomography

    Science.gov (United States)

    Brazio, Philip S.; Laird, Patrick C.; Xu, Chenyang; Gu, Junyan; Burris, Nicholas S.; Brown, Emile N.; Kon, Zachary N.; Poston, Robert S.

    2009-01-01

    Objective Vasospasm is the primary obstacle to widespread adoption of the radial artery as a conduit in coronary artery bypass grafting. We used optical coherence tomography, a catheter-based intravascular imaging modality, to measure the degree of radial artery spasm induced by means of harvest with electrocautery or a harmonic scalpel in patients undergoing coronary artery bypass grafting. Methods Radial arteries were harvested from 44 consecutive patients with a harmonic scalpel (n = 15) or electrocautery (n = 29). Vessels were imaged before harvesting and after removal from the arm, with saphenous vein tracts serving as internal controls. Optical coherence tomographic findings for the degree of harvesting-induced injury were validated against histologic measures. Results Optical coherence tomographic measures of endovascular dimensions and injury correlated strongly with histologic findings. Mean luminal volume, a measure of vasospasm, decreased significantly less after harvesting with a harmonic scalpel (9% ± 7%) than with electrocautery (35% ± 6%, P = .015). Completely intact intima was present in 11 (73%) of 15 radial arteries harvested with a harmonic scalpel (73%) compared with 9 of 29 arteries harvested by means of electrocautery (31%, P = .011). Intraoperative flow measurements and patency rates at 5 days postoperatively were not significantly different among groups. Conclusions Optical coherence tomography provides a level of speed and accuracy for quantifying endothelial injury and vasospasm that has not been described for any other modality, suggesting potential as an intraoperative quality assurance tool. Our optical coherence tomographic findings suggest that the harmonic scalpel induces less spasm and intimal injury compared with electrocautery. PMID:19026820

  20. Comparison of transradial and transfemoral artery approach for percutaneous coronary angiography and angioplasty: A retrospective seven-year experience from a north Indian center

    Directory of Open Access Journals (Sweden)

    Satyendra Tewari

    2013-07-01

    Conclusion: The number of percutaneous transradial procedures have increased significantly with reduced complication rates and comparable success rate to transfemoral approach, along with the additional benefits to patient in terms of patient comfort, preference and reduced cost of health delivery.

  1. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  2. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    2018-01-01

    Full Text Available Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min. Resumo: Objetivo: Diversos relatos alegam que a pressão arterial (PA na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do

  3. Effects of various factors on Doppler ultrasonographic measurements of radial and coccygeal arterial blood pressure in privately owned, conscious cats.

    Science.gov (United States)

    Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I

    2017-04-01

    OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.

  4. Risk of brain injury during diagnostic coronary angiography: comparison between right and left radial approach.

    Science.gov (United States)

    Pacchioni, Andrea; Versaci, Francesco; Mugnolo, Antonio; Penzo, Carlo; Nikas, Dimitrios; Saccà, Salvatore; Favero, Luca; Agostoni, Pier Francesco; Garami, Zsolt; Prati, Francesco; Reimers, Bernhard

    2013-09-10

    To assess the incidence of silent cerebral embolization when using the transradial approach for diagnostic coronary angiography (DCA). Compared to other vascular access sites, the right transradial approach (RTA) could reduce the amount of brain emboli by avoiding mechanical trauma to the aortic wall caused by catheters and wire, whereas it increases manipulation of catheters in the ascending aorta and has a higher risk of direct embolization into the right common carotid artery. A recent study showed an increased incidence of microembolic signals (MES) in RTA compared to femoral. However, left transradial approach (LTA) has never been assessed. 40 patients with suspected coronary artery disease were randomized to DCA via RTA (n=20) or LTA (n=20) with contemporaneous bilateral transcranial Doppler monitoring. MES were detected in all patients, with a significantly higher rate in the RTA group (median 61, interquartile range (IQR) 47-105, vs 48, IQR 31-60, p=0.035). MES generated during procedures needing >2 catheters (n=8), are higher than those detected during procedures performed with 2 catheters (n=32, 102, IQR 70-108, vs 48, IQR 33-60, p=0.001). At multivariate analysis increasing number of catheters was the only independent predictor of high incidence of MES (OR 16.4, 95% CI 1.23-219.9, p=0.034, -2LL=26.7). LTA has a lower risk of brain embolization because of the lower number of catheter exchange maneuvers. Since the degree of brain embolism depends on the magnitude of mechanical manipulation, catheter changes should be minimized to reduce the risk of cerebral embolization. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  5. Radial Artery as a Coronary Artery Bypass Conduit: 20-Year Results.

    Science.gov (United States)

    Gaudino, Mario; Tondi, Paolo; Benedetto, Umberto; Milazzo, Valentina; Flore, Roberto; Glieca, Franco; Ponziani, Francesca Romana; Luciani, Nicola; Girardi, Leonard N; Crea, Filippo; Massetti, Massimo

    2016-08-09

    There is a lack of evidence for the choice of the second conduit in coronary surgery. The radial artery (RA) is a possible option, but few data on very-long-term outcomes exist. This study describes 20-year results of RA grafts used for coronary artery bypass grafting and the effects of RA removal on forearm circulation. We report the results of the prospective 20-year follow-up of the first 100 consecutive patients who received the RA as a coronary bypass conduit at our institution. Follow-up was 100% complete. There were 64 deaths, 23 (35.9%) from cardiovascular causes. Kaplan-Meier 20-year survival was 31%. Of the 36 survivors, 33 (91.6%) underwent RA graft control at a mean of 19.0 ± 2.5 years after surgery. The RA was found to be patent in 24 cases (84.8% patency). In the overall population, probability of graft failure at 20 years was 19.0 ± 0.2% for the left internal thoracic artery (ITA), 25.0 ± 0.2% for the RA, and 55.0 ± 0.2% for the saphenous vein (p = 0.002 for RA vs. saphenous vein, 0.11 for RA vs. ITA, and p 90%, but not location of distal anastomosis, significantly influenced long-term RA graft patency. No patients reported hand or forearm symptoms. The ulnar artery diameter was increased in the operated arm (2.44 ± 0.43 mm vs. 2.01 ± 0.47 mm; p 90% stenosis. RA harvesting does not lead to hand or forearm symptoms, even at a very-long-term follow-up. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  6. Comparison of Safety and Effectiveness Between Right Versus Left Radial Arterial Access in Primary Percutaneous Coronary Intervention for Acute ST Segment Elevation Myocardial Infarction.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; ElMaghawry, Mohamed; Hassan, Mohamed; Kassem, Hussien Heshmat; Said, Karim; Elfaramawy, Amr AbdelAziz

    2017-01-01

    Transradial approach (TRA) is now considered the standard of care in many centres for elective and primary percutaneous intervention (PCI). The use of the radial approach in ST segment elevation myocardial infarction (STEMI) patients has been associated with a significant reduction in major adverse cardiac events. However, it is still unclear if the side of radial access (right vs. left) has impact on safety and effectiveness of TRA in primary PCI. So this study was conducted to compare the safety, feasibility, and outcomes of right radial access (RRA) vs. left radial access (LRA) in the setting of primary PCI. We retrospectively analysed the data of 400 consecutive patients presenting to our institution with STEMI for whom primary PCIs were performed via RRA and LRA. Mean age of the whole studied population was 57±12.8 years, with male predominance (77.2%). There were 202 cases in the RRA group and 198 in the LRA group, with no significant difference in demographics and clinical characteristics for patients included in both groups. There was no significant difference in procedure success rate (97.5% for RRA vs. 98.4% for LRA; P=0.77). In addition, no significant difference between both approaches was observed in the contrast volume, number of catheters, fluoroscopy time (FT), needle-to-balloon time, post-procedure vascular complications, in hospital reinfarction, stroke/transient ischaemic attack (TIA) or death. Right radial access and LRA are equally safe and effective in the setting of primary PCI. Both approaches have a high success rate and comparable needle-to-balloon time. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  7. Transluminal recanalization of chronic total occlusion of radial artery using rendezvous technique: a case report and literature review.

    Science.gov (United States)

    Arabi, Mohammad; Ahmed, Ishtiaq; Qattan, Nabeel

    2014-01-01

    Although endovascular management of lower extremity peripheral arterial disease (PAD) is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO) using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  8. Complex Regional Pain Syndrome after Transradial Cardiac Catheterization

    Directory of Open Access Journals (Sweden)

    Chih-Jou Lai

    2006-04-01

    Full Text Available Complex regional pain syndrome (CRPS is a disease with unclear pathophysiology. The condition is characterized by pain, soft tissue change, vasomotor change, and even psychosocial disturbance. It may affect the upper more than the lower extremities, and the distal more than the proximal. The trigger factors include carpal tunnel release, Dupuytren's repair, tendon release procedures, knee surgery, crush injury, ankle arthrodesis, amputation, and hip arthroplasty. Rarely, it has been associated with stroke, mastectomy, pregnancy, and osteogenesis imperfecta. Herein, we present a rare case of a patient who was diagnosed with CRPS after transradial cardiac catheterization. CRPS was first diagnosed due to hand swelling, allodynia, paresthesia, and the limited range of motion of interphalangeal, metacarpophalangeal, and wrist joints, with the preceding factor of transradial cardiac catheterization, and was then confirmed by a three-phase bone scan. After intensive physical therapy with hydrotherapy, manual soft tissue release, and occupational therapy for the hand function, there was much improvement in range of motion and hand function. There was no allodynia or painful sensation in the follow-up. After training, the functional status of this patient was adequate for daily activity.

  9. Transluminal Recanalization of Chronic Total Occlusion of Radial Artery Using Rendezvous Technique: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohammad Arabi

    2014-01-01

    Full Text Available Although endovascular management of lower extremity peripheral arterial disease (PAD is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  10. Aneurisma sacular da artéria radial: a propósito de um caso clínico Sacular aneurysm of the radial artery: a case report

    Directory of Open Access Journals (Sweden)

    Nádia Duarte

    2011-06-01

    Full Text Available Os aneurismas da artéria radial são raros e esporádicos, sendo que os pseudoaneurismas são mais frequentes do que os aneurismas verdadeiros e maioritariamente de configuração sacular. A etiologia é variada e diferenciam-se de outros diagnósticos pela pulsação e frémito. Raramente se complicam de ruptura, sendo a trombose e embolização as principais complicações. Dos casos publicados sobre aneurismas verdadeiros da artéria radial, apenas um está descrito como sendo secundário a lesão ocupacional repetitiva, sendo a maioria de causa idiopática. Os autores descrevem um caso de uma mulher de 63 anos, referenciada à consulta de Cirurgia Vascular por crescimento de massa pulsátil na tabaqueira anatómica da mão esquerda. O estudo por eco-doppler e angiografia, confirmaram o diagnóstico de aneurisma sacular da artéria radial, com 20 mm de maior eixo, arcada palmar permeável e sem sinais de embolização distal. Foi submetida a aneurismectomia parcial com laqueação dupla proximal e distal e endoaneurismorrafia. A cirurgia e pós-operatório decorreram sem complicações, nomeadamente complicações isquémicas. A propósito desde caso clínico, discute-se a abordagem diagnóstica e opções terapêuticas.Radial artery aneurysms are sporadic and rare, pseudoaneurysms are more common than true aneurysms, mainly in saccular configuration. The etiology is varied and difference from other diagnostics is done by the presence of pulse and thrill. Thrombosis and embolization are the main complications, while rupture is rare. From the reported cases of true aneurysms of the radial artery, only one is described as being secondary to repetitive occupational injury, the majority being idiopathic. The authors describe the case of a 63 year old woman, referred to a Vascular Surgery consultation because of a growing pulsatile mass in the anatomical snuffbox of the left hand. The Doppler and Angiography studies confirmed the diagnosis of

  11. Variations in the usage and composition of a radial cocktail during radial access coronary angiography procedures.

    LENUS (Irish Health Repository)

    Pate, G

    2011-10-01

    A survey was conducted of medication administered during radial artery cannulation for coronary angiography in 2009 in Ireland; responses were obtained for 15 of 20 centres, in 5 of which no radial access procedures were undertaken. All 10 (100%) centres which provided data used heparin and one or more anti-spasmodics; verapamil in 9 (90%), nitrate in 1 (10%), both in 2 (20%). There were significant variations in the doses used. Further work needs to be done to determine the optimum cocktail to prevent radial artery injury following coronary angiography.

  12. The SmartHand transradial prosthesis

    Directory of Open Access Journals (Sweden)

    Carrozza Maria Chiara

    2011-05-01

    Full Text Available Abstract Background Prosthetic components and control interfaces for upper limb amputees have barely changed in the past 40 years. Many transradial prostheses have been developed in the past, nonetheless most of them would be inappropriate if/when a large bandwidth human-machine interface for control and perception would be available, due to either their limited (or inexistent sensorization or limited dexterity. SmartHand tackles this issue as is meant to be clinically experimented in amputees employing different neuro-interfaces, in order to investigate their effectiveness. This paper presents the design and on bench evaluation of the SmartHand. Methods SmartHand design was bio-inspired in terms of its physical appearance, kinematics, sensorization, and its multilevel control system. Underactuated fingers and differential mechanisms were designed and exploited in order to fit all mechatronic components in the size and weight of a natural human hand. Its sensory system was designed with the aim of delivering significant afferent information to the user through adequate interfaces. Results SmartHand is a five fingered self-contained robotic hand, with 16 degrees of freedom, actuated by 4 motors. It integrates a bio-inspired sensory system composed of 40 proprioceptive and exteroceptive sensors and a customized embedded controller both employed for implementing automatic grasp control and for potentially delivering sensory feedback to the amputee. It is able to perform everyday grasps, count and independently point the index. The weight (530 g and speed (closing time: 1.5 seconds are comparable to actual commercial prostheses. It is able to lift a 10 kg suitcase; slippage tests showed that within particular friction and geometric conditions the hand is able to stably grasp up to 3.6 kg cylindrical objects. Conclusions Due to its unique embedded features and human-size, the SmartHand holds the promise to be experimentally fitted on transradial

  13. Medline Plus

    Full Text Available ... Roosevelt Hospital, New York, NY, 1/04/2012) Coronary Artery Disease Transradial Approach for Cardiac Catheterization: The New Frontier ... Center, Winston-Salem, NC, 09/17/2015) Seniors Coronary Artery Disease Transradial Approach for Cardiac Catheterization: The New Frontier ...

  14. Comparação da perviedade entre artéria radial e veia safena em pacientes em pós-operatório de cirurgia de revascularização miocárdica com retorno dos sintomas Comparison of patency between radial artery and saphenous vein in a coronary artery bypass grafting post operative with return of the symptoms

    Directory of Open Access Journals (Sweden)

    Herbert Coelho Hortmann

    2010-06-01

    Full Text Available OBJETIVO: Comparar a perviedade da artéria radial e veia safena em pacientes com retorno dos sintomas após cirurgia de revascularização do miocárdio (CRVM. MÉTODOS: Estudo retrospectivo. No período de janeiro de 1998 a dezembro de 2005, foram realizadas 469 CRVMs com o uso da artéria radial dentre os enxertos, no Hospital Vera Cruz, em Belo Horizonte/MG. Destes, 94 pacientes apresentaram alterações isquêmicas no pós-operatório recente ou tardio e foram reestudados com cineangiocoronariografia. Os enxertos foram divididos em três grupos: artéria torácica interna (ATI, artéria radial (AR e veia safena (VS, e foram estratificados segundo a gravidade das lesões: sem lesão grave (OBJECTIVE: To compare the radial artery and saphenous vein's patency in patients with recurrence of symptoms in a coronary artery bypass grafting (CABG. METHODS: Retrospective study. From January 1998 to December 2005, 469 CABGs were performed using the radial artery as a graft, in Vera Cruz Hospital in Belo Horizonte/ MG. Among the patients who underwent those surgeries, 94 presented ischemic changes in early or late postoperative period, which led them to be re-evaluated by coronary angiography. The grafts were divided in three groups: internal thoracic artery (ITA, radial artery (RA and saphenous vein (SV, and they were stratified according to the severity of injury: uninjured or patent (< 70%, severe obstruction (70 to 99% and occlusion. RESULTS: For the 94 patients in the study, 86 grafts of ITA, 94 of RA and 111 of SV were used. For the 86 ITA grafts, 73 (84.88% were found patent. For the 94 RA grafts, 55 (58.51% were found patent, and for the 111 SV grafts, 73 (65.76% were uninjured. A statistically significant difference (P= 0.001 was found between RA and SV grafts, with a higher patency found for VS graft. For the RA grafts, women presented a worse result concerning the RA patency (65.7% and 40.7%, with P = 0.006. Concerning coronary

  15. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)-Results of the FERARI study.

    Science.gov (United States)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-12-01

    Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose-area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8min, p=0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p=0.826), procedural duration (46.0 vs. 45.0min, p=0.363) and contrast agent use (185.5 vs. 199.5ml, p=0.742) were also similar in radial and femoral PCI. There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  18. Usefulness and Safety of a Guide Catheter Extension System for the Percutaneous Treatment of Complex Coronary Lesions by a Transradial Approach

    OpenAIRE

    García-Blas, Sergio; Núñez, Julio; Mainar, Luis; Miñana, Gema; Bonanad, Clara; Racugno, Paolo; Rodríguez, Juan Carlos; Moyano, Patricia; Sanchis, Juan

    2014-01-01

    Objective The aim of this study was to describe our initial experience with the GuideLiner® catheter (Vascular Solutions Inc.) in the transradial treatment of complex lesions. Materials and Methods The clinical, angiographic and procedural data of percutaneous coronary interventions where GuideLiner was used during 2013 were collected. The transradial approach was used in all cases. The indication for its use, efficacy and periprocedural complications were determined. Sixteen consecutive proc...

  19. The feasibility of transradial laser atherectomy for chronic total occlusion using the 5 Fr sheath system

    Directory of Open Access Journals (Sweden)

    Khaled Sherif

    2016-05-01

    Full Text Available Objective. We present a case of chronic total occlusion (CTO approached with LASER endovascular intervention by radial artery approach using a 5 French sheath. Case report. A 57-year-old man presented to our hospital having had retrosternal chest pain for two days. Physical examination was normal at the time of presentation. The laboratory tests were within normal limits, including cardiac enzymes except the lipid panel which showed hypertriglyceridemia. The patient underwent a myocardial perfusion scintigraphy stress test that revealed inferior wall ischemia, with normal left ventricular ejection fraction. A 5-French vascular sheath was placed in the right radial artery. Selective coronary artery angiography was performed, which showed right coronary artery (RCA CTO. A 5-French JR4 guide catheter successfully engaged the RCA and Laser angioplasty was performed across the CTO into the RCA. A marked improvement of flow was evident thereafter. Conclusion. To best of our knowledge this is the first case report showing the feasibility of laser atherectomy using the 5 French sheath system in a coronary arterial CTO.

  20. The feasibility of transradial laser atherectomy for chronic total occlusion using the 5 Fr sheath system.

    Science.gov (United States)

    Sherif, Khaled; Yaqub, Yasir; Suarez, Jose A

    2016-05-01

    We present a case of chronic total occlusion (CTO) approached with LASER endovascular intervention by radial artery approach using a 5 French sheath. A 57-year-old man presented to our hospital having had retrosternal chest pain for two days. Physical examination was normal at the time of presentation. The laboratory tests were within normal limits, including cardiac enzymes except the lipid panel which showed hypertriglyceridemia. The patient underwent a myocardial perfusion scintigraphy stress test that revealed inferior wall ischemia, with normal left ventricular ejection fraction. A 5-French vascular sheath was placed in the right radial artery. Selective coronary artery angiography was performed, which showed right coronary artery (RCA) CTO. A 5-French JR4 guide catheter successfully engaged the RCA and Laser angioplasty was performed across the CTO into the RCA. A marked improvement of flow was evident thereafter. To best of our knowledge this is the first case report showing the feasibility of laser atherectomy using the 5 French sheath system in a coronary arterial CTO. Copyright © 2016 by Academy of Sciences and Arts of Bosnia and Herzegovina.

  1. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  2. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  3. 2-Octyl Cyanoacrylate (Dermabond® skin adhesive versus polyglactin for skin closure in endoscopic radial artery harvesting

    Directory of Open Access Journals (Sweden)

    Ahmed Mostafa Omran

    2018-03-01

    Full Text Available Background: As the goal of endoscopic conduit harvesting is to decrease pain and better cosmetic appearance, and as the optimal choice of skin closure after endoscopic radial artery harvesting (ERAH has not yet been determined, we started this study with an aim to compare wound complications, patient satisfaction and scar healing between glue (Dermabond versus polyglactin intra-cuticular suture for skin closure after ERAH. Methods: This observational study was done at Al Dabbous Cardiac Center, Kuwait, from January 2017 till October 2017 enrolling 40 patients divided into two equal groups (Dermabond group and sutures group. Inclusion criterion was patients underwent coronary artery bypass grafting (CABG using ERAH, while open technique for radial artery harvesting and Negro race are considered as exclusion criteria. Demographic data were collected, (gender, age, race, body mass index (BMI, preoperative medication and albumin level, as well as diabetes or peripheral vascular disease. Operatively, wound closure time was calculated for all patients. Postoperatively: Cosmetic appearance was assessed using the Hollander scale. Patient satisfaction was recorded at week 6–8 weeks. Results: Demographic and preoperative data were comparable; Dermabond group showed shorter closure time, better scar pigmentation, shape and patient satisfaction. Pain, scar size, infection and hematoma showed no statistical difference. Conclusion: Dermabond can be used safely in closure of skin after ERAH. The excellent results in the small wound of ERAH encouraged us to use it in larger wounds. Keywords: Dermabond, Wound, ERAH, Skin adhesive, OCA

  4. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  5. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    Energy Technology Data Exchange (ETDEWEB)

    Becher, Tobias, E-mail: Tobias.Becher@umm.de [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Mashayekhi, Kambis [Division of Cardiology and Angiology II, University Heart Center Freiburg Bad Krozingen, Bad Krozingen (Germany); Borggrefe, Martin; Akin, Ibrahim [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2016-12-15

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use.

  6. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    International Nuclear Information System (INIS)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-01-01

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use

  7. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  8. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  9. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    International Nuclear Information System (INIS)

    Joshi, Abhay B.; Kalange, Ashok E.; Bodas, Dhananjay; Gangal, S.A.

    2010-01-01

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  10. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  11. Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.

    Science.gov (United States)

    Xie, Zhiyi; Zhang, Zhenyu; Xu, Yuan; Zhou, Hua; Wu, Sheng; Wang, Zhong

    2018-06-01

    In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types. We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups. In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (Ppressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (Parm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5). Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test

  12. Transradial percutaneous coronary intervention for left main bifurcation lesions using 7.5-Fr sheathless guide catheter.

    Science.gov (United States)

    Zhao, Huiqiang; Banerjee, Subhash; Chen, Hui; Li, Hongwei

    2018-05-01

    Recent studies have shown sheathless guide catheters (GCs) to be safe and effective during complex lesions such as bifurcations, chronic total occlusion (CTO), and/or calcified lesions. We investigated the feasibility and safety of using 7.5-Fr sheathless GC for transradial percutaneous coronary intervention (PCI) to treat left main bifurcation lesions.A total of 82 patients were consecutively enrolled from March 2013 to February 2016. They underwent transradial PCI for left main bifurcation lesions using the 7.5-Fr sheathless GC.The mean syntax score was 28.1 ± 6.1, and the majority (n = 55, 67.1%) was intermediate scores (23∼32). The unprotected LM disease was present in 67 of 82 patients (81.7%), and true bifurcation (Medina 1, 1, 1) was present in 46 of 82 patients (56.1%). The 2-stent technique was used in 62 of 82 patients (75.6%). The 2-stent technique included 31 cases (37.8%) of "Crush," 18 cases (22.0%) of "Cullote," and 13 (15.8%) cases of "T stent and modified T stent" (T stent). Immediate angiographic success rate was 100% (82/82), and procedural success rate was 97.6% (80/82). The vascular complications occurred in 3 patients (3/82, 3.7%).The use of 7.5-Fr sheathless GC is safe and allows PCI for complex bifurcation lesions located in the distal of left main to be performed transradially with a high success rate.

  13. Determination of the luminal diameter of the radial artery in man by high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1990-01-01

    measurements. By comparing the diameter of the reference object either filled with water or blood at 37 degrees C, the ultrasound velocity in human blood at 37 degrees C was calculated to be 1605 m/s. The intraobserver repeatability coefficients of in-vivo measurements of the radial artery in man were...... in the same range, whether measurements were repeated after 30 min (14%) or from day to day (12%). The interobserver repeatability coefficient was acceptable (15%) when the site of measurements was marked, whereas measurements without a mark resulted in a repeatability coefficient of 24%. The intravenous...

  14. A coincidental variation of the axillary artery: the brachioradial artery and the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Marek Konarik

    2014-09-01

    Full Text Available A case of anomalous terminal branching of the axillary artery was encountered and described in a left upper limb of a male cadaver. A series of 214 upper limbs of Caucasian race was dissected. A variant artery, stemming from the very end of the axillary artery followed a superficial course distally. It passed the cubital fossa, ran on the lateral side of the forearm as usual radial artery, crossed ventrally to the palm and terminated in the deep palmar arch. This vessel is a case of the brachioradial artery (incorrectly termed as the “radial artery with high origin”. Moreover, it was associated with another variation, concerning the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle. The anatomical knowledge of the axillary region is essential for radiodiagnostic, surgical and traumatologic procedures. The superficially located artery brings an elevated danger of heavy bleeding in all unexpected situations, its variant branching can cause problems in radial catheterization procedures and the anomalously coursing other arterial variant poses an elevated danger in surgical procedures concerning the surgical neck of humerus.

  15. Revealing the impact of local access-site complications and upper extremity dysfunction post transradial percutaneous coronary procedures

    NARCIS (Netherlands)

    Zwaan, E.M.; Koopman, A.G.M.M.; Holtzer, C.A.J.; Zijlstra, F.; Ritt, M.J.P.F.; Amoroso, G.; Moerman, E.; Kofflard, M.J.M.; Ijsselmuiden, A.J.J.

    2015-01-01

    Objectives Little is known about local access-site complications and upper extremity dysfunction after transradial percutaneous coronary procedures (TR-PCP). This systematic review study aimed to summarise the current knowledge on the incidences of access-site complications and upper extremity

  16. A randomised controlled study of standard versus accelerated deflation of the Terumo radial band haemostasis device after transradial diagnostic cardiac catheterisation

    NARCIS (Netherlands)

    Deuling, J. Han; Vermeulen, Robert P.; van den Heuvel, A. F. M.; Schurer, Remco A. J.; van der Harst, Pim

    2017-01-01

    Background: Radial access is the preferential access route in patients undergoing diagnostic coronary angiography. We hypothesised that we could reduce hospital stay and improve patient comfort by accelerated deflation of the radial compression device (Terumo radial band). Aims: The aim of this

  17. A randomised controlled study of standard versus accelerated deflation of the Terumo radial band haemostasis device after transradial diagnostic cardiac catheterisation.

    Science.gov (United States)

    Deuling, J Han; Vermeulen, Robert P; van den Heuvel, Ad Fm; Schurer, Remco Aj; van der Harst, Pim

    2017-04-01

    Radial access is the preferential access route in patients undergoing diagnostic coronary angiography. We hypothesised that we could reduce hospital stay and improve patient comfort by accelerated deflation of the radial compression device (Terumo radial band). The aim of this study was to compare accelerated pressure reduction with a standard Terumo radial band protocol with regard to local bleeding complications and reported pain scores after cardiac catheterisation. We performed a single centre prospective randomised trial to compare accelerated care to standard care for patients undergoing diagnostic catheterisation through radial access. Patients in the accelerated care group started deflation after 1 hour, with a 2 ml/10-minute interval. Patients in the standard care group started after 2 hours with additional steps of deflation at 3 and 4 hours. Of the 173 analysed patients 86 received accelerated care and 87 patients standard care. A total of 19 patients had pulsatile bleeding, which occurred similarly in the two groups (standard care 11 vs. accelerated care 8, P=0.47). The time to Terumo radial band removal was on average 129 minutes shorter for accelerated care patients compared to standard care ( P<0.01). At 1 hour after Terumo radial band placement, accelerated care patients more often reported pain scores of 0 than standard care patients (89% vs. 74%, P=0.02). There was no increase in local bleedings in the accelerated pressure reduction of the Terumo radial band after diagnostic cardiac catheterisation, increasing patient comfort and reducing hospital stay. These findings will further facilitate the widespread implementation of radial access.

  18. Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    Science.gov (United States)

    Fyrdahl, Alexander; Vargas Paris, Roberto; Nyrén, Sven; Holst, Karen; Ugander, Martin; Lindholm, Peter; Sigfridsson, Andreas

    2018-03-14

    To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were imaged at 1.5 T using a Cartesian and golden-angle radial 2D balanced SSFP pulse sequence. The acquisitions were made under free breathing without contrast agent enhancement. The radial acquisitions were reconstructed at 3 temporal footprints. All series were scored from 1 to 5 for perceived diagnostic quality, artifact level, and vessel sharpness in multiple anatomical locations. In addition, vessel sharpness and blood-to-blood clot contrast were measured. Quantitative measurements showed higher vessel sharpness for golden-angle radial (n = 76, 0.79 ± 0.11 versus 0.71 ± 0.16, p golden-angle radial in the 2 patients. At comparable temporal footprints, golden-angle radial was scored higher for diagnostic quality (mean ± SD, 2.3 ± 0.7 versus 2.2 ± 0.6, p < .01) and vessel sharpness (2.2 ± 0.8 versus 2.1 ± 0.5, p < .01), whereas the artifact level did not differ (3.0 ± 0.9 versus 3.0 ± 1.0, p = .80). The ability to retrospectively choose a temporal resolution and perform sliding-window reconstructions was demonstrated in patients. In pulmonary artery imaging, the motion and flow robustness of a radial trajectory does both improve image quality over Cartesian trajectory in healthy volunteers, and allows for flexible selection of temporal footprints and the ability to perform real-time sliding window reconstructions, which could potentially provide further diagnostic insight. © 2018 International Society for Magnetic Resonance in Medicine.

  19. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  20. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Stark, Christopher, E-mail: Christopher.stark@uvmhealth.org [University of Vermont Medical Center, Department of Radiology (United States); Olsen, Daniel [Mayo Clinic, Department of Pathology (United States); Morris, Christopher [University of Vermont Medical Center, Department of Radiology (United States); Bertges, Daniel [University of Vermont Medical Center, Department of Surgery (United States); Najarian, Kenneth [University of Vermont Medical Center, Department of Radiology (United States)

    2016-11-15

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  1. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    International Nuclear Information System (INIS)

    Stark, Christopher; Olsen, Daniel; Morris, Christopher; Bertges, Daniel; Najarian, Kenneth

    2016-01-01

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  2. Efficacy and safety of transradial percutaneous coronary intervention using sheathless guide catheter technique

    Directory of Open Access Journals (Sweden)

    Mohamed Aboel-Kassem F. Abdelmegid

    2014-03-01

    Conclusions: TR PCI via standard and sheathless hydrophilic-coated GC techniques are effective and safe with high rate of procedural success and low rate of asymptomatic radial artery occlusion. Moreover, TR PCI using sheathless GC technique has the advantage of performing complex intervention requiring large bore catheters that can not be performed via standard TR PCI using 6F GC.

  3. Efficacy of a one-catheter concept for transradial coronary angiography.

    Directory of Open Access Journals (Sweden)

    Christoph Langer

    Full Text Available Transradial coronary angiography (TRC can be performed with a one-catheter approach for the right and left coronary ostium (R/LCO. We investigated the performance of a special diagnostic catheter widely used for the one-catheter-approach, the Tiger (Tiger II, TerumoTM.In a dual center registry we analyzed 1412 TRC-procedures exclusively performed by experienced TRC-operators. We compared the performance of the Tiger with Judkins catheters by retrospectively judging ostial catheter stability during contrast injection, and by measuring contrast use, fluoroscopy time (FT and complication rate.Poor or failed ostial engagement was found in 40.5% in the Tiger group, compared to 46.6% with the use of Judkins catheters (p<0.183. Ostial instability of the Tiger was found more often during engagement of the LCO than the RCO (34.4% vs. 10.8%, p<0.001, whereas it was similar in the LCO and RCO for Judkins catheters (27.4% vs. 26.7%, p = 0.840. TRC-procedures performed with Tiger catheters were associated with less contrast volume (63.48 ± 29.83mL vs. 82.51 ± 56.58mL, p<0.004 and shorter FT than with Judkins catheters. (198.27 ± 194.8sec vs. 326.85 ± 329.70sec. Forearm hematomas occurred less often with the Tiger (1.2% vs. 6.6%, p< 0.02.The Tiger employed as a single catheter in TRC is an effective tool to achieve lower contrast volume and fluoroscopy time at a low complication rate. Unstable engagement affects predominantly the left coronary artery, but its overall frequency is similar for both, the Tiger and Judkins catheters.

  4. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  5. Effects of gravity-induced upper-limb blood pressure changes on wave transmission and arterial radial waveform.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Sanesi, Leandro; Gavish, Benjamin; Butlin, Mark; Avolio, Alberto; Schillaci, Giuseppe

    2016-06-01

    Local blood pressure (BP) changes induced by arm tilting may influence pressure wave transmission and reflection. We investigated the effects of upper-limb tilting on radial augmentation index (rAIx) and related central measures [aortic augmentation index (aAIx)]. In 45 volunteers (age 49 ± 19 years), supine brachial BP and radial artery waveforms were obtained by applanation tonometry with the dominant arm stretched and gently supported in three different positions: at the heart level, with the BP cuff 15 cm above heart level (approximately +30°), and 15 cm below heart level (-30°). Brachial SBP/DBP was 120/68 ± 17/8 mmHg. Mean arterial pressure changed predictably with arm tilting (99 ± 12 mmHg at -30°, 88 ± 10 mmHg at 0°, 77 ± 11 mmHg at +30°, all P < 0.001). rAIx decreased at -30° (69 ± 22%), and increased at +30° (93 ± 20%) compared with 0° (82 ± 20%, all P less than 0.001). Changes in rAIx (value at +30° minus value at -30°) showed an inverse relationship with age (r = -0.32, P = 0.03). Heart rate, BP and rAIx did not change in the contralateral arm, which was held at the heart level during the examination. aAIx followed the same pattern as rAIx (123 ± 27% at -30°, 144 ± 33% at +30°, 136 ± 31% at 0°, all P less than 0.001); changes in rAIx and aAIx were strongly related each other (r = 0.82, P < 0.001). Acute gravitational upper-limb BP changes generate opposite, profound changes in rAIx, and major artifactual changes in aAIx. These findings provide a rationale for recommending to keep the upper limb at the heart level during radial waveform assessment.

  6. Reduction of scatter radiation during transradial percutaneous coronary angiography: a randomized trial using a lead-free radiation shield.

    Science.gov (United States)

    Politi, Luigi; Biondi-Zoccai, Giuseppe; Nocetti, Luca; Costi, Tiziana; Monopoli, Daniel; Rossi, Rosario; Sgura, Fabio; Modena, Maria Grazia; Sangiorgi, Giuseppe M

    2012-01-01

    Occupational radiation exposure is a growing problem due to the increasing number and complexity of interventional procedures performed. Radial artery access has reduced the number of complications at the price of longer procedure duration. Radpad® scatter protection is a sterile, disposable bismuth-barium radiation shield drape that should be able to decrease the dose of operator radiation during diagnostic and interventional procedures. Such radiation shield has never been tested in a randomized study in humans. Sixty consecutive patients undergoing coronary angiography by radial approach were randomized 1:1 to Radpad use versus no radiation shield protection. The sterile shield was placed around the area of right radial artery sheath insertion and extended medially to the patient trunk. All diagnostic procedures were performed by the same operator to reduce variability in radiation absorption. Radiation exposure was measured blindly using thermoluminescence dosimeters positioned at the operator's chest, left eye, left wrist, and thyroid. Despite similar fluoroscopy time (3.52 ± 2.71 min vs. 3.46 ± 2.77 min, P = 0.898) and total examination dose (50.5 ± 30.7 vs. 45.8 ± 18.0 Gycm(2), P = 0.231), the mean total radiation exposure to the operator was significantly lower when Radpad was utilized (282.8 ± 32.55 μSv vs. 367.8 ± 105.4 μSv, P Radpad utilization at all body locations ranging from 13 to 34% reduction. This first-in-men randomized trial demonstrates that Radpad significantly reduces occupational radiation exposure during coronary angiography performed through right radial artery access. Copyright © 2011 Wiley Periodicals, Inc.

  7. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  8. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    Science.gov (United States)

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  9. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  10. A comparison of direct technique with the liquid stylet technique of radial artery cannulation in patients presenting for coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Younus, U.; Ahmed, I.

    2012-01-01

    To compare direct technique with the liquid stylet technique of radial artery cannulation in patients undergoing coronary artery byroms grouping. We hypothesized that liquid stylet technique would lead to fewer attempts and save vital time. Study Design: Randomized controlled Trial (RCT). Place and Duration of Study: Department of Anaesthesia and Intensive Care, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, [AFIC-NIHD] Rawalpindi, between 1 July 2007 to 31 Dec 2007. Patients and Methods: One hundred patients of either sex scheduled for CABG were included and were randomized to 2 groups using random number table. Fifty patients in the direct technique group and 50 in the liquid stylet group. Results: These two groups comparable with respect to age, gender and weight were studied. The number of attempts in group 1 were 1.7+-0.5 vs 3.6+-1.6 in groups 2, (p=0.021). The time consumed in group was 3.3 +- 2.2 minutes while in groups 2 it was 8.0 +- 3.6 (p=0.022). Conclusion: We concluded that the liquid stylet technique is safe, quick and is associated with lesser number of attempts at cannulation. Secondly it can be done without fancy guide wires and other technology especially in a developing country like Pakistan. (author)

  11. Unintentional arterial puncture during cephalic vein cannulation: case report and anatomical study

    NARCIS (Netherlands)

    Lirk, P.; Keller, C.; Colvin, J.; Colvin, H.; Rieder, J.; Maurer, H.; Moriggl, B.

    2004-01-01

    The cephalic antebrachial vein is often used for venous access. However, superficial radial arteries of the forearm are known and unintentional arterial puncture can result from attempts to cannulate the lateral veins of the arm. Accidental puncture of a superficial radial artery during peripheral

  12. Radial artery pulse waveform analysis based on curve fitting using discrete Fourier series.

    Science.gov (United States)

    Jiang, Zhixing; Zhang, David; Lu, Guangming

    2018-04-19

    Radial artery pulse diagnosis has been playing an important role in traditional Chinese medicine (TCM). For its non-invasion and convenience, the pulse diagnosis has great significance in diseases analysis of modern medicine. The practitioners sense the pulse waveforms in patients' wrist to make diagnoses based on their non-objective personal experience. With the researches of pulse acquisition platforms and computerized analysis methods, the objective study on pulse diagnosis can help the TCM to keep up with the development of modern medicine. In this paper, we propose a new method to extract feature from pulse waveform based on discrete Fourier series (DFS). It regards the waveform as one kind of signal that consists of a series of sub-components represented by sine and cosine (SC) signals with different frequencies and amplitudes. After the pulse signals are collected and preprocessed, we fit the average waveform for each sample using discrete Fourier series by least squares. The feature vector is comprised by the coefficients of discrete Fourier series function. Compared with the fitting method using Gaussian mixture function, the fitting errors of proposed method are smaller, which indicate that our method can represent the original signal better. The classification performance of proposed feature is superior to the other features extracted from waveform, liking auto-regression model and Gaussian mixture model. The coefficients of optimized DFS function, who is used to fit the arterial pressure waveforms, can obtain better performance in modeling the waveforms and holds more potential information for distinguishing different psychological states. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Non-gated vessel wall imaging of the internal carotid artery using radial scanning and fast spin echo sequence. Evaluation of vessel signal intensity by flow rate at 3.0 tesla

    International Nuclear Information System (INIS)

    Nakamura, Manami; Makabe, Takeshi; Ichikawa, Masaki; Hatakeyama, Ryohei; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-01-01

    Vessel wall imaging using radial scanning does not use a blood flow suppression pulse with gated acquisition. It has been proposed that there may not be a flow void effect if the flow rate is slow; however, this has yet to be empirically tested. To clarify the relationship between the signal intensity of the vessel lumen and the blood flow rate in a flow phantom, we investigated the usefulness of vessel wall imaging at 3.0 tesla (T). We measured the signal intensity while changing the flow rate in the flow phantom. Radial scanning at 1.5 T showed sufficient flow voids at above medium flow rates. There was no significant difference in lumen signal intensity at the carotid artery flow rate. The signal intensity of the vessel lumen decreased sufficiently using the radial scan method at 3.0 T. We thus obtained sufficient flow void effects at the carotid artery flow rate. We conclude this technique to be useful for evaluating plaque if high contrast can be maintained for fixed tissue (such as plaque) and the vessel lumen. (author)

  14. Investigation of occupational radiation exposure during interventional cardiac catheterizations performed via radial artery

    International Nuclear Information System (INIS)

    Goni, H.; Papadopoulou, D.; Yakoumakis, Em; Stratigis, N.; Benos, J.; Siriopoulou, V.; Makri, Tr; Georgiou, Ev

    2005-01-01

    The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angio-plasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterizations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm 2 for each procedure. Staff radiation doses varied between 34 and 235 μGy per procedure at the left wrist, 28 and 172 μGy at the right wrist, 16 and 106 μGy at the level of the thyroid and 16 and 154 μGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm 2 . Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs. (authors)

  15. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. The effect of nitric oxide synthase inhibition on histamine induced headache and arterial dilatation in migraineurs

    DEFF Research Database (Denmark)

    Lassen, L H; Christiansen, I; Iversen, Helle Klingenberg

    2003-01-01

    -decrease in MCA blood velocity, or dilatation of neither the temporal nor the radial artery. L-NMMA constricted the temporal artery by 8% before histamine infusion, whereas the radial artery was unaffected. The temporal artery dilated 4-5 times more than the radial artery during histamine infusion. In conclusion...... the use of a NOS inhibitor in the highest possible dose did not block the histamine-induced headache response or arterial dilatation. Either the concentration of L-NMMA reaching the smooth muscle cell was insufficient or, histamine dilates arteries and causes headache via NO independent mechanisms. Our...... results showed for the first time a craniospecificity for the vasodilating effect of histamine and for the arterial effects of NOS inhibition....

  17. Identifying factors that predict the choice and success rate of radial artery catheterisation in contemporary real world cardiology practice: a sub-analysis of the PREVAIL study data.

    Science.gov (United States)

    Pristipino, Christian; Roncella, Adriana; Trani, Carlo; Nazzaro, Marco S; Berni, Andrea; Di Sciascio, Germano; Sciahbasi, Alessandro; Musarò, Salvatore Donato; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio

    2010-06-01

    To assess: the reasons behind an operator choosing to perform radial artery catheterisation (RAC) as against femoral arterial catheterisation, and to explore why RAC may fail in the real world. A pre-determined analysis of PREVAIL study database was performed. Relevant data were collected in a prospective, observational survey of 1,052 consecutive patients undergoing invasive cardiovascular procedures at nine Italian hospitals over a one month observation period. By multivariate analysis, the independent predictors of RAC choice were having the procedure performed: (1) at a high procedural volume centre; and (2) by an operator who performs a high volume of radial procedures; clinical variables played no statistically significant role. RAC failure was predicted independently by (1) a lower operator propensity to use RAC; and (2) the presence of obstructive peripheral artery disease. A 10-fold lower rate of RAC failure was observed among operators who perform RAC for > 85% of their personal caseload than among those who use RAC < 25% of the time (3.8% vs. 33.0%, respectively); by receiver operator characteristic (ROC) analysis, no threshold value for operator RAC volume predicted RAC failure. A routine RAC in all-comers is superior to a selective strategy in terms of feasibility and success rate.

  18. Radiation safety and vascular access: attitudes among cardiologists worldwide

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States); Khan, Asrar A. [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States); Xie, Hui [Division of Epidemiology and Biostatistics and Cancer Center, University of Illinois at Chicago, Chicago, Illinois (United States); Shroff, Adhir R. [Department of Medicine, Division of Cardiology, University of Illinois at Chicago, Chicago, Illinois (United States)

    2015-03-15

    Objectives: To determine opinions and perceptions of interventional cardiologists on the topic of radiation and vascular access choice. Background: Transradial approach for cardiac catheterization has been increasing in popularity worldwide. There is evidence that transradial access (TRA) may be associated with increasing radiation doses compared to transfemoral access (TFA). Methods: We distributed a questionnaire to collect opinions of interventional cardiologists around the world. Results: Interventional cardiologists (n = 5332) were contacted by email to complete an on-line survey from September to October 2013. The response rate was 20% (n = 1084). TRA was used in 54% of percutaneous coronary interventions (PCIs). Most TRAs (80%) were performed with right radial access (RRA). Interventionalists perceived that TRA was associated with higher radiation exposure compared to TFA and that RRA was associated with higher radiation exposure that left radial access (LRA). Older interventionalists were more likely to use radiation protection equipment and those who underwent radiation safety training gave more importance to ALARA (as low as reasonably achievable). Nearly half the respondents stated they would perform more TRA if the radiation exposure was similar to TFA. While interventionalists in the United States placed less importance to certain radiation protective equipment, European operators were more concerned with physician and patient radiation. Conclusions: Interventionalists worldwide reported higher perceived radiation doses with TRA compared to TFA and RRA compared to LRA. Efforts should be directed toward encouraging consistent radiation safety training. Major investment and application of novel radiation protection tools and radiation dose reduction strategies should be pursued. - Highlights: • We examined radiation safety and arterial access practices among 1000 cardiologists. • Radial access is perceived as having higher radiation dose compared to

  19. Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan

    Directory of Open Access Journals (Sweden)

    Nurhusna N

    2017-08-01

    Full Text Available Page Header User Username Password Remember me Editorial Team Editor Policies Mechanism & Ethics Author Guideline Reference Tools: About The Authors Nurhusna N Indonesia F Sri Susilaningsih Purwo Suwigjo Article Tools Print this article Indexing metadata How to cite item Finding References Review policy Email this article (Login required Email the author (Login required Information For Readers For Authors For Librarians Journal Content Search Search Scope Browse By Issue By Author By Title Home About Login Register Search Current Archives Announcements Register Index Contact Us Home > Vol 2, No 1 (2014 > N Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan Nurhusna N, F Sri Susilaningsih, Purwo Suwigjo Abstract Radial artery occlusion merupakan salah satu komplikasi vaskular postkateterisasi jantung trans radial. Kompresi lokal menggunakan alat kompresi setelah tindakan kateterisasi jantung trans radial dapat menurunkan angka kejadian komplikasi vaskular Radial Artery Occlusion(RAO. Penelitian ini bertujuan untuk mengetahui perbandingan antara metode Barbeau test dan metode pengamatan klinik dalam menilai keutuhan arteri radialis selama proses kompresi pada pasien postprosedur kateterisasi jantung trans radial. Penelitian ini merupakan penelitian kuantitatif dengan desain studi komparatif. Subjek penelitian adalah 20 pasien yang menjalani prosedur kateterisasi jantung dengan akses arteri radialis. Pengukuran dilakukan secara bertahap menit ke-15 dan setelah tiga jam menggunakan alat kompresi stepty-p. Uji komparasi menggunakan uji McNemar. Data univariat dianalisis menggunakan distribusi frekuensi. Hasil uji statistik menunjukkan ada perbedaan penilaian keutuhan arteri radialis antara metode Barbeau testdengan metode pengamatan klinik pada menit ke-15 (p=0.035 dan ke-30 (p=0.035. Namun secara keseluruhan hasil uji statistik menunjukkan tidak ada perbedaan yang bermakna dalam menilai kepatenan arteri pada

  20. Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke

    International Nuclear Information System (INIS)

    Bok, Tae Hoon; Kong, Qi; Nam, Kweon Ho; Choi, Jay Chol; Paeng, Dong Guk

    2012-01-01

    In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group (0.13±0.21 and 0.16±0.03). PIBE of CCA for the young group, however, was larger than that for the old group (0.70±0.21 and 0.32±0.01), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients (336±61 and 340±126 mg/dl) were more than that of the control group (264±38 and 43 mg/dl), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

  1. Brachiomedian artery (arteria brachiomediana revisited: a comprehensive review

    Directory of Open Access Journals (Sweden)

    David Kachlik

    2016-03-01

    Full Text Available This article reviews in detail the superficial brachiomedian artery (arteria brachiomediana superficialis, a very rare variant of the main arterial trunks of the upper limb. It branches either from the axillary artery or the brachial artery, descends superficially in the arm (similar to the course of the superficial brachial artery and continues across the cubital fossa, runs superficially in the forearm, approaches the median nerve and enters the carpal canal to reach the hand. It usually terminates in the superficial palmar arch. The first drawing was published, in 1830, and the first description was published, in 1844. Altogether, to our knowledge, only 31 cases of a true, superficial brachiomedian artery have been reported (Some cases are incorrectly reported as superficial brachioradiomedian artery or superficial brachioulnomedian artery. Based on a meta-analysis of known, available studies, the incidence is 0.23% in Caucasians and 1.48% in Mongolians. Knowing whether or not this arterial variant is present is important in clinical medicine and relevant for: The catheterization via the radial or ulnar artery; harvesting the vascular pedicle for a forearm flap based on the radial, ulnar or superficial brachiomedian arteries; the possible collateral circulation in cases of the arterial closure; and the surgical management of carpal tunnel syndrome. Its presence can elevate the danger of an injury to the superficially located variant artery or of an accidental injection.

  2. A unique branching pattern of the axillary artery: a case report.

    Science.gov (United States)

    Bagoji, Ishwar B; Hadimani, Gavishiddappa A; Bannur, Balappa M; Patil, B G; Bharatha, Ambadasu

    2013-12-01

    During routine dissection classes for under graduate students, we found a unique and unusual case regarding the anomalous branching in the third part of the axillary artery was terminated into subscapular arterial trunk, superficial brachial artery and deep brachial artery. The subscapular arterial trunk was origin of several important arteries as the circumflex scapular, thoracodorsal, posterior circumflex humeral, thoraco-acromial and lateral thoracic arteries. The deep brachial artery in the arm gave anterior circumflex humeral artery at the surgical neck of humerus, which terminated in the cubital fossa by dividing into radial and ulnar arteries. The superficial brachial artery gave two profunda brachii arteries, both of which passed through spiral groove, along with radial nerve and three muscular branches, to brachialis muscle. This variation is very rare. As per our knowledge, we did not find any literature which explained variations which were similar to this. The normal and abnormal anatomy of the axillary region has practical importance among vascular radiologists and surgeons and it should be known for making an accurate diagnostic interpretation.

  3. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  4. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    Science.gov (United States)

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  5. An anatomical study of variations in termination of brachial artery, with its embryological basis and clinical significance

    Directory of Open Access Journals (Sweden)

    Deepa T. K

    2016-03-01

    Full Text Available The brachial artery is the main artery of the arm. It begins as the continuation of 3rd part of axillary artery, at the level of inferior border of teres major muscle. It ends at the level of the neck of radius by dividing into radial and ulnar arteries. In the present study we found higher division of brachial artery at mid arm level into its terminal branches with superficial course of radial artery. The present study was done on 51 cadavers from our dept. of Anatomy. The upper limbs of the cadaver were dissected and observed for any variations in the branching pattern of brachial artery. In the present study, a total number of 51 cadaver’s, 102 upper limbs were studied. In one male cadaver we found bilateral higher division of brachial artery, trifurcation on left side and bifurcation on right side brachial artery, with superficial course of radial artery. The knowledge of variation in origin and course of brachial artery is useful for orthopaedicians, physicians, radiologist, vascular and plastic surgeons.

  6. Long-term monitoring of arterial pO2 in burned patients.

    Science.gov (United States)

    Nilsson, E; Arnander, C

    1984-02-01

    Five patients, who were treated in a special ward for burns were followed by continuous intra-arterial pO2 monitoring for a total of 1612 h (range 13-604 h). The pao2 catheter electrodes used were surface-heparinized, and inserted either in the radial or the femoral artery. Some electrodes were accidentally withdrawn. Recalibration was performed for two of the 10 electrodes used. These electrodes presented a changed sensitivity after heavy stretching of the sensor during the nursing. The sensitivity of one of these electrodes was altered downwards and the other one upwards. After recalibration the pao2 electrodes presented accurate values for the rest of the monitoring period. Without compensation for drift, the pao2 electrode readout was compared to the results of traditional blood-gas analysis, which served as a reference. The regression function found was y = -0.62 + 1.04 chi (r = 0.93, SD = 1.40, n = 60). The blood flow velocity around some of the pao2 electrodes was studied by the pulsed Doppler technique. There was no influence of the surface-heparinized pao2 electrode on the femoral artery blood flow velocity as compared to the contralateral, non-catheterized femoral artery. The blood flow velocity proximal to a traditional radial artery catheter was compared to the flow velocity in the contralateral radial artery containing a surface-heparinized pao2 electrode. The surface-heparinized electrode did not decrease the mean flow velocity in contrast with the traditional radial artery catheter, which had to be withdrawn after 8 days because of clotting. The surface-heparinized catheter electrode was still monitoring pao2 accurately after 25 days in the artery, which was the longest period studied for a particular sensor.

  7. N-acetylcysteine enhances nitroglycerin-induced headache and cranial arterial responses

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg

    1992-01-01

    The effects of N-acetylcysteine, a sulfhydryl group donor, on nitroglycerin-induced headache and dilation of temporal and radial arteries were investigated in 11 healthy volunteers. Nitroglycerin, 0.06 microgram/kg/min, was infused for 20 minutes immediately after and 120 minutes after pretreatment...... response (median headache score, 3 versus 1), and the headache retained its vascular characteristics. Temporal artery dilation was also potentiated by N-acetylcysteine, 139% +/- 3% versus 127% +/- 3% of baseline, whereas the radial artery was unaffected. The potentiation was most pronounced after the first...... nitroglycerin infusion (12% versus 4.5% compared with placebo). A prolonged dilation of the temporal artery was observed only after the first nitroglycerin infusion, when high levels of N-acetylcysteine were present....

  8. EXERCISE-INDUCED ARTERIAL ADAPTATIONS IN ELITE JUDO ATHLETES

    Directory of Open Access Journals (Sweden)

    Panagiotis Karagounis

    2009-09-01

    Full Text Available The purpose of this study was to examine exercise-induced arterial adaptations in elite Judo male and female athletes. 27 male Judo athletes (age 24.06 ± 2 years, 11 female Judoka (age 24.27 ± 1 years, 27 sedentary healthy men (age 24.01 ± 2 years and 11 women (age 24.21 ± 1 years participated in the current study. The examined vessels included brachial, radial, ulnar, popliteal, anterior and posterior tibial arteries. The experimental parameters were recorded with the use of Duplex ultrasound at rest. Diastolic diameter and blood mean flow velocity of the examined arteries in Judo athletes were found to be both significantly increased (p < 0.05 compared to the findings of the control groups. In male Judo athletes the brachial (p < 0.001, radial (p < 0.001, and anterior tibial artery (p < 0.001 presented the highest difference on the diastolic diameter, compared with the control male group. In female Judo athletes, ulnar (p < 0.001, radial (p < 0.001, and brachial (p < 0.001 arteries illustrated the highest diastolic diameter. The highest blood mean flow velocity was recorded in ulnar (p < 0.001 and popliteal arteries (p < 0.001 of the Judo athletes groups. Recording differences between the two genders, male participants presented larger arteries than females. Conclusively, Judo has been found to be a highly demanding physical sport, involving upper and lower limbs leading to significant arterial adaptations. Obtaining vascular parameters provide a useful tool to the medical team, not only in the direction of enhancement of the efficacy of physical training, but in unknown so far parameters that may influence athletic performance of both male and female elite Judokas

  9. [Alterations in arterial compliance of dyslipidemic patients].

    Science.gov (United States)

    Clara, Fernando Mario; Corral, Pablo; Blanco, Gustavo Hector; Scandurra, Adriana Graciela; Meschino, Gustavo Javier

    2015-01-01

    We studied the alteration on the distensibility of the arterial walls caused by dyslipidemia LDLc dependent, along the decades of life, by means of a study of the radial artery pulse wave. We made an analysis of the radial artery pulse wave records acquired by means a movement displacement sensor, placed on radial palpation area. We recruited 100 dyslipidemic men without other cardiovascular risk factors, between the 3rd and the 6th decade. We identified the reflected wave in the records and we computed the augmentation index in order to quantify its amplitude and position. This index is useful to assess the endothelial dysfunction. Besides, we defined a velocity coefficient as the ratio between the size of the individuals and the delay time between the peak of the systolic wave and the arrival of the reflected wave. Results were compared against those obtained in a group of 161 healthy volunteers. We found that dyslipidemic patients presented augmentation index values similar to controls until the fourth decade, increasing thereafter with significant differences only in the 6th decade. No significant differences were found in the velocity index in any of the ages studied. We conclude that alterations produced by dyslipidemia take decades to manifest, and they begin affecting the mechanism of vasodilation of distal arteries with highest proportion of smooth muscle, without altering the proximal conduit arteries with more elastin content. Copyright © 2013 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  10. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  11. Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency

    Directory of Open Access Journals (Sweden)

    D. M. Galaktionov

    2017-11-01

    Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest. 

  12. The relationship between total arterial revascularization and blood transfusion following coronary artery bypass grafting.

    Science.gov (United States)

    Djordjevic, Jasmina; Ngaage, Dumbor L

    2015-05-01

    Blood transfusion adversely affects the outcome of coronary artery bypass grafting (CABG), yet blood transfusion after CABG is still common. Total arterial revascularisation (TAR) is increasingly used in current practice but its impact on postoperative blood transfusion is not known. We reviewed the cardiothoracic and blood bank databases and collected data for isolated primary CABG patients from July 2007 to June 2012, excluding patients who had a single graft (n = 148). Perioperative variables of TAR patients (n = 745) were compared with patients who had one or more venous grafts (SVG, n = 1,761) for first-time isolated CABG. The conduits used in TAR patients were predominantly left internal thoracic and radial arteries. Matched group comparison of TAR and SVG patients was performed. The association of TAR with blood transfusion was investigated using multivariate and matched analysis. Of 2,506 patients, the 745 (29.7 %) that had TAR were generally younger, with less complex coronary artery disease and less often diabetic. After correcting for these by 1:1 matching, the mean chest tube drainage and rates of blood transfusion remained significantly lower (p transfused in TAR patients. By multivariate analysis, TAR had an independent effect on reducing blood transfusion after CABG [odds ratio (OR) 0.67, 95 % confidence interval (CI) 0.47-0.97, p = .03]. TAR achieved predominantly with left internal thoracic and radial arteries substantially reduced blood transfusion rates after primary CABG. Further studies are warranted.

  13. Safety and Outcomes of Transradial Access in Patients with International Normalized Ratio 1.5 or above.

    Science.gov (United States)

    Titano, Joseph J; Biederman, Derek M; Zech, John; Korff, Ricki; Ranade, Mona; Patel, Rahul; Kim, Edward; Nowakowski, Francis; Lookstein, Robert; Fischman, Aaron M

    2018-03-01

    To examine the safety and outcomes for patients undergoing transradial noncoronary interventions with international normalized ratio (INR) ≥1.5. A retrospective review of 2,271 transradial access (TRA) cases performed from July 2012 to July 2016 was conducted. Criteria for inclusion were moderate bleeding risk cases with preprocedure INR ≥1.5. Within the study period, there were 176 moderate bleeding risk procedures (transarterial chemoembolization: 70/176 [39.8%]; Barbeau B: 121/176 [68.8%]; 5-F sheath: 157/176 [89.2%]) performed on 122 patients (age 61.6 ± 12.1 years, 68.9% male, body mass index 28.0 kg/m 2 ) with INR ≥1.5. Technical success was achieved in 98.9% of cases. Grade 1/2 hematomas developed in 10 cases (5.7%). Age ≥65 years (P = .042) and female sex (P = .046) were predictive of access site bleeding complications. Fresh frozen plasma (FFP) transfusion was administered in 11.4% of cases (n = 20). Baseline INR and creatinine were significantly different between transfused and nontransfused cases (P values .006 and .028, respectively). Minor access site bleeding occurred in 3/20 cases (15%) receiving prior FFP transfusion and 7/156 nontransfused cases (4.5%), with no significant difference between these 2 groups (P = .072). TRA in patients with elevated INR appears to be safe in our experience. Age ≥65 years and female sex were associated with increased incidence of access site bleeding. Although INR correction was not standardized in this cohort, preprocedure FFP transfusion did not decrease bleeding complications. Copyright © 2017 SIR. Published by Elsevier Inc. All rights reserved.

  14. Dose-dependent headache response and dilatation of limb and extracranial arteries after three doses of 5-isosorbide-mononitrate

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Garre, K

    1992-01-01

    of the temporal artery, but not for the radial artery. It is concluded that headache after 5-ISMN is caused by arterial dilatation or by mechanisms responsible for the arterial dilatation. Ultrasound monitoring of arterial diameters is an important and sensitive tool in the evaluation of nitrates and other...... and placebo on separate days. The diameters of the radial and superficial temporal arteries were repeatedly measured with high frequency ultrasound and pain was scored using a 10 point verbal scale. A clear dose-relationship was found for plasma concentrations and headache, and for changes in the diameter...

  15. Thrombosis of digital arteries associated with tamoxifen use: case report.

    Science.gov (United States)

    Hutchison, Richard L; Rayan, Ghazi M

    2012-02-01

    Arterial thrombosis in the upper extremity occurs often at the wrist. We report a unique case of thrombosis that involved multiple digital arteries, without radial or ulnar artery involvement, which developed only after using tamoxifen despite chronic occupational blunt percussive hand use. Revascularization was achieved after thrombectomy. Multiple digital arterial thromboses may complicate the use of tamoxifen. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  16. Cardiological-interventional therapy of coronary artery disease today

    International Nuclear Information System (INIS)

    Reynen, K.; Henssge, R.

    1999-01-01

    The current importance of the interventional therapy of coronary artery disease may be deduced from the exponential increase in procedures performed in Germany in the last decade - at least 125,840 in 1996. Today, by improved catheter and balloon materials as well as by growing experience of the cardiologists, even complex lesions may be treated. Limitations of balloon angioplasty include acute vessel closure and restenosis - newer angioplasty devices like directional or rotational atherectomy or excimer-laser angioplasty did not overcome these limitations; only by coronary stenting, acute vessel closure could be managed and the likelihood of restenosis - at least in particular groups of patients - could be reduced. For a few years, intracoronary brachytherapy of the segments dilated with beta- or gamma-emitters has been seeking to reduce restenosis rate; the department of cardiology of the Dresden Cardiovascular Institute is participating in such a multicentre study using the beta-emitter 188 renium. Further main topics of our department represent primary angioplasty in patients with acute myocardial infarction and invasive diagnostic or interventional procedures by the transradial approach. (orig.)

  17. Radial forearm free flap morbidity: A rare case of a normal preoperative arteriogram and acute intraoperative hand ischemia

    OpenAIRE

    Bruner, Terrence W; Hanasono, Matthew M; Skoracki, Roman J

    2011-01-01

    The radial forearm free flap is ideal for reconstructive microsurgery due to its thin, pliable fasciocutaneous tissue, reliable anatomy and ease and simplicity of flap elevation. However, one of the major complications is hand ischemia due to sacrifice of the radial artery, although it is a rare occurrence. A case involving a 73-year-old man who developed intraoperative hand ischemia after elevation of a radial forearm free flap is presented.

  18. Arterial stiffness in 10-year-old children: current and early determinants.

    Science.gov (United States)

    Schack-Nielsen, Lene; Mølgaard, Christian; Larsen, Dorthe; Martyn, Christopher; Michaelsen, Kim Fleischer

    2005-12-01

    It has been suggested that CVD has its origins in early life. An impairment of fetal growth and early postnatal nutrition may have programming effects on cardiovascular physiology. In addition, traditional risk factors for CVD may initiate the atherosclerotic process during childhood. We explored the effect of fat intake, physical activity and lipid profile in childhood, and birth weight, growth during infancy and breast-feeding on arterial stiffness in a cohort study of ninety-three 10-year-old children followed during infancy and re-examined at the age of 10 years. Arterial stiffness in two arterial segments (aorto-radial and aorto-femoral) was measured as pulse wave velocity. Arterial stiffness was inversely associated with physical activity (a regression coefficient in cm/s (95 % CI) of -6.8 (-11.2, -2.4) and -3.9 (-6.9, -0.8) per h of high physical activity/d in the aorto-radial and aorto-femoral segments, respectively). Arterial stiffness was also positively associated with dietary fat energy percentage (3.1 (95 % CI 0.9, 5.2) and 1.8 (95 % CI 0.2, 3.2) per fat energy percentage in the aorto-radial and aorto-femoral segments, respectively) but was not related to body composition, insulin resistance or lipid profile. Arterial stiffness was also positively associated with duration of breast-feeding for the aorto-femoral segment only (2.1 (95 % CI 0.4, 3.7) per month) but was not associated with growth in early life. In conclusion, patterns of physical activity and diet, and history of breast-feeding in infancy, have an influence on the stiffness of the large arteries in children. The long-term effects of this are unknown.

  19. Upper limb artery segmental occlusions due to chronic use of ergotamine combined with itraconazole, treated by thrombolysis

    Directory of Open Access Journals (Sweden)

    Nodari Franco

    2011-08-01

    Full Text Available Abstract Background The ergotamine tartrate associated with certain categories of drugs can lead to critical ischemia of the extremities. Discontinuation of taking ergotamine is usually sufficient for the total regression of ischemia, but in some cases it could be necessary thrombolytic and anticoagulant therapy to avoid amputation. Case report A woman of 62 years presented with a severe pain left forearm appeared 10 days ago, with a worsening trend. The same symptoms appeared after 5 days also in the right forearm. Physical examination showed the right arm slightly hypothermic, with radial reduced pulse in presence of reduced sensitivity. The left arm was frankly hypothermic, pulse less on radial and with an ulnar humeral reduced pulse, associated to a decreased sensitivity and motility. Clinical history shows a chronic headache for which the patient took a daily basis for years Cafergot suppository (equivalent to 3.2 mg of ergotamine. From about ten days had begun therapy with itraconazole for vaginal candidiasis. The Color-Doppler ultrasound shown arterial thrombosis of the upper limbs (humeral and radial bilateral, with minimal residual flow to the right and no signal on the humeral and radial left artery. Results Angiography revealed progressive reduction in size of the axillary artery and right humeral artery stenosis with right segmental occlusions and multiple hypertrophic collateral circulations at the elbow joint. At the level of the right forearm was recognizable only the radial artery, decreased in size. Does not recognize the ulnar, interosseous artery was thin. To the left showed progressive reduction in size of the distal subclavian and humeral artery, determined by multiple segmental steno-occlusion with collateral vessels serving only a thin hypotrophic interosseous artery. Arteriographic findings were compatible with systemic drug-induced disease. The immediate implementation of thrombolysis, continued for 26 hours, with

  20. Rotational atherectomy ablation for an unexpandable stent under the guide of IVUS

    Science.gov (United States)

    Si, Daoyuan; Liu, Guohui; Tong, Yaliang; He, Yuquan

    2018-01-01

    Abstract Rationale: Inadequate stent expansion due to rigid calcified may result in restenosis lesions, but the available options are limited. Patient concerns: We report a case via the trans-radial approach of the severely underexpanded freshly deployed stent due to heavily calcified plaques Diagnoses: Coronary angiography revealed that there was no adequate expansion of the freshly deployed stent. Interventions: Under the guide of intravascular ultrasound (IVUS), rotational atherectomy (RA) successfully ablated the stent layers and the protruding calcified plaque. Followed by balloon angioplasty, the ablated segment was scaffolded with another stent, well expanded and documented by IVUS. Outcomes: The patient was uneventful during the procedure and remained angina free at the point of one year of clinical follow-up. Lessons: This case indicated that RA via the trans-radial approach could be a useful remedy in the situation of under-expansion of implanted stents, and the debulking should be performed under IVUS-guidance. PMID:29443790

  1. Medline Plus

    Full Text Available ... New York, NY, 1/04/2012) Coronary Artery Disease Transradial Approach for Cardiac Catheterization: The New Frontier ... Medical Center, Chicago, IL, 6/26/2014) Heart Diseases Transesophageal Echocardiogram (TEE) (Shawnee Mission Medical Center, Merriam, ...

  2. Medline Plus

    Full Text Available ... Circulation Angioplasty Transradial Approach for Cardiac Catheterization: The New Frontier of Coronary Intervention (University of Chicago Medical ... to Treat Obstructive Hypertrophic Cardiomyopathy (HCM) (Roosevelt Hospital, New York, NY, 1/04/2012) Coronary Artery Disease ...

  3. Radial oxygen gradients over rat cortex arterioles

    OpenAIRE

    Galler, Michael

    2011-01-01

    Purpose: We present the results of the visualisation of radial oxygen gradients in rats’ cortices and their use in neurocritical management. Methods: PO2 maps of the cortex of 10 wistar rats were obtained with a camera (SensiMOD, PCO, Kehlheim, Germany). Those pictures were analyzed and edited by a custom-made software. We chose a vessel for examination. A matrix, designed to evaluate the cortical O2 partial pressure, was placed vertically to the artery and afterwards multiple regio...

  4. Arterial endothelial function measurement method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Maltz, Jonathan S; Budinger, Thomas F

    2014-03-04

    A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

  5. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  6. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  7. Comparative efficacy and safety of the left versus right radial approach for percutaneous coronary procedures: a meta-analysis including 6870 patients

    Directory of Open Access Journals (Sweden)

    S.L. Xia

    2015-08-01

    Full Text Available The radial approach is widely used in the treatment of patients with coronary artery disease. We conducted a meta-analysis of published results on the efficacy and safety of the left and right radial approaches in patients undergoing percutaneous coronary procedures. A systematic search of reference databases was conducted, and data from 14 randomized controlled trials involving 6870 participants were analyzed. The left radial approach was associated with significant reductions in fluoroscopy time [standardized mean difference (SMD=-0.14, 95% confidence interval (CI=-0.19 to -0.09; P<0.00001] and contrast volume (SMD=-0.07, 95%CI=-0.12 to -0.02; P=0.009. There were no significant differences in rate of procedural failure of the left and the right radial approaches [risk ratios (RR=0.98; 95%CI=0.77-1.25; P=0.88] or procedural time (SMD=-0.05, 95%CI=0.17-0.06; P=0.38. Tortuosity of the subclavian artery (RR=0.27, 95%CI=0.14-0.50; P<0.0001 was reported more frequently with the right radial approach. A greater number of catheters were used with the left than with the right radial approach (SMD=0.25, 95%CI=0.04-0.46; P=0.02. We conclude that the left radial approach is as safe as the right radial approach, and that the left radial approach should be recommended for use in percutaneous coronary procedures, especially in percutaneous coronary angiograms.

  8. Medline Plus

    Full Text Available ... to Treat Obstructive Hypertrophic Cardiomyopathy (HCM) (Roosevelt Hospital, New York, NY, 1/04/2012) Coronary Artery Disease Transradial ... Heart Failure Surgical Ventricular Reconstruction (Montefiore Medical Center, New York, NY, 2/13/2008) Heart Health Tests Transesophageal ...

  9. Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, Moritz H. [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Varga-Szemes, Akos; Schoepf, U.J.; Xu, Jiaqian; Jin, Kwang-Nam; Hlavacek, Anthony M.; Chowdhury, Shahryar M.; Suranyi, Pal; Tesche, Christian; De Cecco, Carlo N.; Nutting, Arni [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); Apfaltrer, Georg [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Graz, Department of Radiology, Graz (Austria); Piccini, Davide [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Siemens Healthcare, IM BM PI, Advanced Clinical Imaging Technology, Lausanne (Switzerland); Stuber, Matthias; Ginami, Giulia [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2018-03-15

    To evaluate a self-navigated free-breathing three-dimensional (SNFB3D) radial whole-heart MRA technique for assessment of main coronary arteries (CAs) and side branches in patients with congenital heart disease (CHD). SNFB3D-MRA datasets of 109 patients (20.1±11.8 years) were included. Three readers assessed the depiction of CA segments, diagnostic confidence in determining CA dominance, overall image quality and the ability to freeze cardiac and respiratory motion. Vessel sharpness was quantitatively measured. The percentages of cases with excellent CA depiction were as follows (mean score): left main, 92.6 % (1.92); left anterior descending (LAD), 88.3 % (1.88); right (RCA), 87.8 % (1.85); left circumflex, 82.8 % (1.82); posterior descending, 50.2 % (1.50) and first diagonal, 39.8 % (1.39). High diagnostic confidence for the assessment of CA dominance was achieved in 56.2 % of MRA examinations (mean score, 1.56). Cardiac motion freezing (mean score, 2.18; Pearson's r=0.73, P<0.029) affected image quality more than respiratory motion freezing (mean score, 2.20; r=0.58, P<0.029). Mean quantitative vessel sharpness of the internal thoracic artery, RCA and LAD were 53.1, 52.5 and 48.7 %, respectively. Most SNFB3D-MRA examinations allow for excellent depiction of the main CAs in young CHD patients; visualisation of side branches remains limited. (orig.)

  10. Patients undergoing PCI from the femoral route by default radial operators are at high risk of vascular access-site complications.

    Science.gov (United States)

    Rafie, Ihsan M; Uddin, Muez M; Ossei-Gerning, Nicholas; Anderson, Richard A; Kinnaird, Timothy D

    2014-02-01

    Radial artery (RA) access for PCI has a lower incidence of vascular access-site (VAS) complications than the femoral artery (FA) approach. However, even for default radial operators certain patients are intervened upon from the FA. We examined the demographics and incidence of VAS complications when default radial operators resort to the FA for PCI. The demographics and VAS complications were compared by access site retrospectively for all PCI cases performed by default radial operators (n=1,392). A modified ACUITY trial definition of major VAS complication was used. FA puncture occurred in 25.2% (351/1,392) of cases. Patients were more likely to be female, older and weigh less than patients undergoing PCI from the RA. The FA procedure was likely to be more complex with larger sheaths, more left main stem, graft and multivessel intervention, and there was a greater proportion of emergency cases. Despite increased case complexity, glycoprotein inhibitors were used less frequently in femoral cases (26.5% vs. 36.8%, prisk factors for access-site bleeding are disproportionately high in the population requiring FA puncture by default radial operators, and as a result such patients have a high rate of vascular access-site complications.

  11. Congenital Arterial Thrombosis in Newborn: a Case Report

    OpenAIRE

    Özdemir, Özmert M. A.; Özdemir, Yavuz; Kılıç, İlknur; Güleç, Bülent; Sücüllü, İlker; Küçüktaşçı, Kazım; Filiz, Ali İlker; Gürses, Dolunay; Karaca, Abdullah; Oto, Murat; Çetin, Gökhan Ozan; Caner, Vildan

    2014-01-01

    Neonatal thrombosis is a serious event that can cause mortality or severe morbidity. Although catheters are the most common cause of neonatal thrombosis, spontaneous events can also occur. Arterial thrombosis is very rare and accounts for approximately half of all thrombotic events in neonates. Genetic prothrombotic risk factors may affect the occurence of neonatal thrombosis. In this report, a case of left brachial, radial, and ulnar arterial thrombosis associated with methylene-tetrahydrofo...

  12. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    International Nuclear Information System (INIS)

    Andrade, Pedro Beraldo de; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André; Hernandes, Mauro Esteves; Marino, Roberto Luiz; Precoma, Dalton Bertolim; Sá, Francisco Carleial Feijó de; Berwanger, Otávio; Mattos, Luiz Alberto Piva e

    2014-01-01

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques

  13. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Pedro Beraldo de, E-mail: pedroberaldo@cardiol.br; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André [Santa Casa de Misericórdia de Marília, São Paulo -SP (Brazil); Hernandes, Mauro Esteves [Santa Casa de Votuporanga, São Paulo -SP (Brazil); Marino, Roberto Luiz [Hospital Madre Teresa, Belo Horizonte -MG (Brazil); Precoma, Dalton Bertolim [Sociedade Hospital Angelina Caron, Campina Grande do Sul -PR (Brazil); Sá, Francisco Carleial Feijó de [Hospital do Coração do Cariri, Barbalha -CE (Brazil); Berwanger, Otávio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo -SP (Brazil); Mattos, Luiz Alberto Piva e [Sociedade Brasileira de Cardiologia, São Paulo -SP (Brazil); Instituto Dante Pazzanese de Cardiologia, São Paulo -SP (Brazil); Unidades de Hemodinâmica e Intervenção Cardiovascular Rede D' Or / São Luiz, São Paulo, SP (Brazil)

    2014-06-15

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  14. Small arteries can be accurately studied in vivo, using high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1993-01-01

    We have validated measurements of diameters of the superficial temporal artery and other small arteries in man with a newly developed 20 MHz ultrasound scanner with A, B and M-mode imaging. The diameter of a reference object was 1.202 mm vs. 1.205 mm as measured by stereomicroscopy (nonsignifican......-gauge plethysmography (nonsignificant). Pulsations were 4.6% in the radial artery. We conclude that high frequency ultrasound provides an accurate and reproducible measure of the diameter of small and medium sized human arteries in vivo....

  15. HyPro: A Multi-DoF Hybrid-Powered Transradial Robotic Prosthesis

    Directory of Open Access Journals (Sweden)

    C. L. Semasinghe

    2018-01-01

    Full Text Available This paper proposes a multi-DoF hybrid-powered transradial robotic prosthesis, named HyPro. The HyPro consists of two prosthetic units: hand and wrist that can achieve five grasping patterns such as power grasp, tip grasp, lateral grasp, hook grasp, and index point. It is an underactuated device with 15 degrees of freedom. A hybrid powering concept is proposed and implemented on hand unit of HyPro where the key focus is on restoration of grasp functions of biological hand. A novel underactuated mechanism is introduced to achieve the required hand preshaping for a given grasping pattern using electric power in the pregrasp stage and body power is used in grasp stage to execute the final grasping action with the selected fingers. Unlike existing hybrid prostheses where each of the joints is separately controlled by either electric or body power, the proposed prosthesis is capable of delivering grasping power in combination. The wrist unit of HyPro is designed and developed to achieve flexion-extension and supination-pronation using electric power. Experiments were carried out to evaluate the functionality and performance of the proposed hybrid-powered robotic prosthesis. The results verified the potential of HyPro to perform intended grasping patterns effectively and efficiently.

  16. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2014-07-01

    Full Text Available Background: The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. Objective: To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. Methods: From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. Results: The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. Conclusions: The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  17. Use and outcome of radial versus femoral approach for primary PCI in patients with acute ST elevation myocardial infarction without cardiogenic shock: results from the ALKK PCI registry.

    Science.gov (United States)

    Bauer, Timm; Hochadel, Matthias; Brachmann, Johannes; Schächinger, Volker; Boekstegers, Peter; Zrenner, Bernhard; Zahn, Ralf; Zeymer, Uwe

    2015-10-01

    This study sought to compare the use and outcome of radial versus femoral access in patients treated with primary percutaneous coronary intervention (PCI) for acute ST elevation myocardial infarction (STEMI) in clinical practice. The radial approach for PCI in patients with STEMI has been suggested to have a lower rate of complications and bleeding and to improve prognosis compared with the femoral approach. However, there still is a large regional and national variation in its use. Between 2008 and 2012 a total of 17,865 patients with STEMI without cardiogenic shock undergoing primary PCI were prospectively enrolled in the observational German PCI registry of the Arbeitsgemeinschaft leitende kardiologische Krankenhausärzte (ALKK). Transfemoral (TF) access was used in 15,270 (85.5%), transradial (TR) access in 2,530 (14.2%), and other access in 65 (0.3%) patients. In this analysis, 10,264 patients from 20 centers that had performed at least 5 TR-PCI for STEMI were included. This study compared TR-PCI (n = 2,454 23.9%) with TF-PCI (n = 7,810, 76.1%). Procedural success was high in both cohorts. Hospital mortality (1.8 vs. 5.1%, P PCI can be performed with excellent procedural success in selected STEMI patients and is associated with a lower rate of vascular access complications and hospital mortality. © 2015 Wiley Periodicals, Inc.

  18. Arterial diameter during central volume depletion in humans

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Madsen, P; Matzen, S

    1995-01-01

    The luminal diameter of the radial artery was followed by high frequency ultrasound during 50 degrees head-up tilt-induced central volume depletion in ten healthy subjects of whom six were tilted twice and pretreated with the serotonin receptor antagonist methysergide or placebo following a double...

  19. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    Science.gov (United States)

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Central Hemodynamics and Arterial Stiffness in Systemic Sclerosis.

    Science.gov (United States)

    Bartoloni, Elena; Pucci, Giacomo; Cannarile, Francesca; Battista, Francesca; Alunno, Alessia; Giuliani, Marco; Cafaro, Giacomo; Gerli, Roberto; Schillaci, Giuseppe

    2016-12-01

    Although microvascular disease is a hallmark of systemic sclerosis (SSc), a higher prevalence of macrovascular disease and a poorer related prognosis have been reported in SSc than in the general population. The simultaneous assessment of prognostically relevant functional properties of larger and smaller arteries, and their effects on central hemodynamics, has never been performed in SSc using the state-of-the-art techniques. Thirty-four women with SSc (aged 61±15 years, disease duration 17±12 years, and blood pressure 123/70±18/11 mm Hg) and 34 healthy women individually matched by age and mean arterial pressure underwent the determination of carotid-femoral (aortic) and carotid-radial (upper limb) pulse wave velocity (a direct measure of arterial stiffness), aortic augmentation (a measure of the contribution of reflected wave to central pulse pressure), and aortobrachial pulse pressure amplification (brachial/aortic pulse pressure) through applanation tonometry (SphygmoCor). Patients and controls did not differ by carotid-femoral or carotid-radial pulse wave velocity. Aortic augmentation index corrected for a heart rate of 75 bpm (AIx@75) was higher in women with SSc (30.9±16% versus 22.2±12%; P=0.012). Patients also had a lower aortobrachial amplification of pulse pressure (1.22±0.18 versus 1.33±0.25; P=0.041). SSc was an independent predictor of AIx@75 (direct) and pulse pressure amplification (inverse). Among patients, age, mean arterial pressure, and C-reactive protein independently predicted carotid-femoral pulse wave velocity. Age and mean arterial pressure were the only predictors of AIx@75. Women with SSc have increased aortic augmentation and decreased pulse pressure amplification (both measures of the contribution of reflected wave to central waveform) but no changes in aortic or upper limb arterial stiffness. Microvascular involvement occurs earlier than large artery stiffening in SSc. © 2016 American Heart Association, Inc.

  1. Human urotensin II in internal mammary and radial arteries of patients undergoing coronary surgery

    DEFF Research Database (Denmark)

    Chen, Zhi-Wu; Yang, Qin; Huang, Yu

    2009-01-01

    (max):20.4+/-4.8%, p7.1%). The relaxation was abolished by endothelium denudation...... and by indomethacin, oxadiazoloquinoxalinone or N(omega)-nitro-L-arginine, oxyhemoglobin, and Ca2+-activated K+ channel (K(Ca)) blockers. Urotensin receptor mRNA was detected in both arteries. CONCLUSIONS: hU-II is an important spasmogen in arterial grafts with receptors expressed in IMA and RA. hU-II elicits...

  2. The phosphodiesterase 3 inhibitor cilostazol dilates large cerebral arteries in humans without affecting regional cerebral blood flow

    DEFF Research Database (Denmark)

    Birk, Steffen; Kruuse, Christina Rostrup; Petersen, Kenneth A

    2004-01-01

    in the middle cerebral arteries (VMCA) was measured with transcranial Doppler, and the superficial temporal and radial arteries diameters were measured with ultrasonography. During the 4-hour observation period, there was no effect on systolic blood pressure (P = 0.28), but diastolic blood pressure decreased...

  3. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  4. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  5. Successful flow reduction surgery for a ruptured true posterior communicating artery aneurysm caused by the common carotid artery ligation for epistaxis.

    Science.gov (United States)

    Yamao, Yukihiro; Takahashi, Jun C; Satow, Tetsu; Iihara, Koji; Miyamoto, Susumu

    2014-01-01

    Carotid artery occlusion can lead to the development of rare true posterior communicating artery (PCoA) aneurysms because of hemodynamic stress on the PCoA. Surgical treatment of these lesions is challenging. The authors report a case of a true PCoA aneurysm that developed and ruptured 37 years after ligation of the ipsilateral common carotid artery for epistaxis. The lesion was successfully treated with clipping of the distal M1 segment of the middle cerebral artery (MCA) after the occipital artery-radial artery free graft-MCA bypass, which led to extreme reduction in collateral flow through the PCoA. A cortical branch, located just proximal to the obliteration site, functioned as a sufficient flow outlet. The aneurysm shrank, and the patient has been doing well without any symptoms for 5 years after surgery. M1 obliteration combined with high-flow extra-intracranial bypass might be a promising option for a true PCoA aneurysm, and therapeutic design that leaves a sufficient flow outlet on the M1 is mandatory to avoid unexpected occlusion of the M1 and its perforators.

  6. Cardiological-interventional therapy of coronary artery disease today; Kardiologisch-interventionelle Therapie der koronaren Herzerkrankung heute

    Energy Technology Data Exchange (ETDEWEB)

    Reynen, K.; Henssge, R. [Technische Univ. Dresden (Germany). Klinik fuer Kardiologie

    1999-07-01

    The current importance of the interventional therapy of coronary artery disease may be deduced from the exponential increase in procedures performed in Germany in the last decade - at least 125,840 in 1996. Today, by improved catheter and balloon materials as well as by growing experience of the cardiologists, even complex lesions may be treated. Limitations of balloon angioplasty include acute vessel closure and restenosis - newer angioplasty devices like directional or rotational atherectomy or excimer-laser angioplasty did not overcome these limitations; only by coronary stenting, acute vessel closure could be managed and the likelihood of restenosis - at least in particular groups of patients - could be reduced. For a few years, intracoronary brachytherapy of the segments dilated with beta- or gamma-emitters has been seeking to reduce restenosis rate; the department of cardiology of the Dresden Cardiovascular Institute is participating in such a multicentre study using the beta-emitter {sup 188}renium. Further main topics of our department represent primary angioplasty in patients with acute myocardial infarction and invasive diagnostic or interventional procedures by the transradial approach. (orig.)

  7. Fatores associados ao aumento no índice de incremento de pressão radial em indivíduos hipertensos Factors associated with increased radial augmentation index in hypertensive individuals

    Directory of Open Access Journals (Sweden)

    Renan Oliveira Vaz-de-Melo

    2011-09-01

    Full Text Available FUNDAMENTO: A rigidez arterial é uma variável preditora de morbimortalidade e um possível marcador de lesão vascular. Sua avaliação não invasiva por tonometria radial e análise do índice de incremento (r-AI permite identificar os pacientes expostos a um maior risco cardiovascular. OBJETIVO: Analisar a influência do r-AI em variáveis clínico-bioquímicas e sua influência na prevalência de dano em órgão-alvo em pacientes hipertensos. MÉTODOS: Cento e quarenta pacientes hipertensos consecutivos, em seguimento clínico ambulatorial, foram submetidos à análise transversal. Os níveis de pressão arterial (PA e o r-AI foram obtidos por tonometria de aplanação da artéria radial (HEM-9000AI, Onrom. Os pacientes foram alocados em tercis r-AI (r-AI 97%. RESULTADOS: A amostra era predominantemente composta por mulheres (56,4%, com idade média de 61,7 ± 11,7 anos e índice de massa corporal de 29,6 ± 6,1 Kg/m². O maior tercil apresentou uma proporção maior de mulheres (p = 0,001, maior PA sistólica (p = 0,001 e pressão de pulso (p = 0,014, e menor peso (p = 0,044, altura (p BACKGROUND: Arterial stiffness is a variable predictor of morbidity and mortality and a possible marker of vascular injury. Its non-invasive assessment by radial tonometry and analysis of the augmentation index (r-AI allows identifying patients exposed to higher cardiovascular risk. OBJECTIVE: To analyze the influence of r-AI on clinical-biochemical variables and its influence on the prevalence of target-organ damage in hypertensive patients. METHODS: 140 consecutive hypertensive patients, followed-up in an outpatient clinic, were analyzed in a cross-sectional study. Blood pressure (BP levels and r-AI were obtained by applanation tonometry of the radial artery (HEM-9000AI, Onrom. The patients were allocated into r-AI tertiles (r-AI 97%. RESULTS: The sample was predominantly composed of women (56.4%, mean age of 61.7 ± 11.7 years and body mass index 29.6

  8. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  9. Hand-arm vibration syndrome with distal brachial artery occlusion

    Directory of Open Access Journals (Sweden)

    Vladyslava Bazylevska

    2017-01-01

    Full Text Available Abstract             Hand-arm vibration syndrome (HAVS is a complex disorder of the peripheral extremities that is associated with occupational or recreational exposure to hand-transmitted vibration. Digital artery occlusion in HAVS is a common finding; however, proximal involvement is less likely.  We present a case of HAVS with the initial presentation of acute limb ischemia and with thrombus burden extending from the distal brachial artery and into the ulnar and radial arteries. To our knowledge, no case of HAVS syndrome of similar severity has been previously described. This case emphasizes the potential dangers of HAVS and the necessity for proper prophylactic interventions at the workplace.

  10. Hemodynamics alter arterial low-density lipoprotein metabolism

    International Nuclear Information System (INIS)

    Warty, V.S.; Calvo, W.J.; Berceli, S.A.; Pham, S.M.; Durham, S.J.; Tanksale, S.K.; Klein, E.C.; Herman, I.M.; Borovetz, H.S.

    1989-01-01

    We have investigated the role of hemodynamic factors on low-density lipoprotein transport and metabolism in the intact arterial wall. Freshly excised canine carotid blood vessels were exposed to well-defined pulsatile flow in vitro for continuous periods up to 20 hours. We chose to impose the following hemodynamic conditions on our test carotid arteries: normotension, hypertension (at physiologic flow conditions), and hypertension coupled with elevated flow of canine serum perfusate. In several experiments the effect of endothelial denudation was examined in carotid arteries exposed to normotensive pulsatile flow. A trapped ligand method was used for quantitating low-density lipoprotein uptake and metabolism in the arterial wall. The distribution of both intact and degraded low-density lipoprotein fractions was determined from measurements of radiolabelled low-density lipoprotein activity within thin radial sections of perfused arteries. Our results suggest that both hypertensive hemodynamic simulations exacerbate the uptake of low-density lipoprotein within the arterial wall (by a factor of three to nine). The percentage of low-density lipoprotein that undergoes irreversible degradation falls from 41% under normotensive conditions to below 30% when hypertensive conditions are imposed, indicating that degradative processes are not proportionally elevated with the accelerated influx. A similar pattern is observed for deendothelialized vessels

  11. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  12. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  13. Stability of radial and non-radial pulsation modes of massive ZAMS models

    International Nuclear Information System (INIS)

    Odell, A.P.; Pausenwein, A.; Weiss, W.W.; Hajek, A.

    1987-01-01

    The authors have computed non-adiabatic eigenvalues for radial and non-radial pulsation modes of star models between 80 and 120 M solar with composition of chi=0.70 and Z=0.02. The radial fundamental mode is unstable in models with mass greater than 95 M solar , but the first overtone mode is always stable. The non-radial modes are all stable for all models, but the iota=2 f-mode is the closest to being driven. The non-radial modes are progressively more stable with higher iota and with higher n (for both rho- and g-modes). Thus, their results indicate that radial pulsation limits the upper mass of a star

  14. Energy harvesting from arterial blood pressure for powering embedded brain sensors

    Science.gov (United States)

    Nanda, Aditya; Karami, M. Amin

    2016-04-01

    This paper investigates energy harvesting from arterial blood pressure via the piezoelectric effect by using a novel streaked cylinder geometry for the purpose of powering embedded micro-sensors in the brain. Initially, we look at the energy harvested by a piezoelectric cylinder placed inside an artery acted upon by blood pressure. Such an arrangement would be tantamount to constructing a stent out of piezoelectric materials. A stent is a cylinder placed in veins and arteries to prevent obstruction in blood flow. The governing equations of a conductor coated piezoelectric cylinder are obtained using Hamilton's principle. Pressure acting in arteries is radially directed and this is used to simplify the modal analysis and obtain the transfer function relating pressure to the induced voltage across the surface of the harvester. The power harvested by the cylindrical harvester is obtained for different shunt resistances. Radially directed pressure occurs elsewhere and we also look at harvesting energy from oil flow in pipelines. Although the energy harvested by the cylindrical energy harvester is significant at resonance, the natural frequency of the system is found to be very high. To decrease the natural frequency, we propose a novel streaked stent design by cutting it along the length, transforming it to a curved plate and decreasing the natural frequency. The governing equations corresponding to the new geometry are derived using Hamilton's principle and modal analysis is used to obtain the transfer function.

  15. Acesso radial em intervenções coronarianas percutâneas: panorama atual brasileiro Acceso radial en intervenciones coronarias percutáneas: panorama actual brasileño Radial approach in percutaneous coronary interventions: current status in Brazil

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2011-04-01

    fue comparado al femoral (2,5% versus 3,6%, p BACKGROUND: Although the radial approach offers an unquestionable result in terms of reduction of vascular complications and occurrence of severe bleeding in comparison to the femoral approach, so far it has only been used in few centers which elected it as the preferential access. OBJECTIVE: To evaluate the current status of percutaneous coronary interventions in Brazil, as regards the use of the radial approach. METHODS: Analysis of data spontaneously recorded in Central Nacional de Intervenções Cardiovasculares - CENIC (National Center for Cardiovascular Interventions from 2005 to 2008, in a total of 83,376 procedures. RESULTS: The radial approach was used in 12.6% of the procedures performed, and the femoral approach, in 84.3%. The remaining 3.1% corresponded to brachial artery dissection or puncture. With a success rate of 97.5%, the choice of the radial approach was associated with a significant reduction of vascular complications in comparison to the femoral approach (2.5% versus 3.6 %, p < 0.0001. CONCLUSION: The radial approach remains uncommonly used in Brazil, and this is possibly explained by the lack of training programs, uncertainties regarding the learning curve, and the lack of large-scale studies corroborating the benefits demonstrated to date.

  16. Development of a polymer endovascular prosthesis and its implantation in porcine arteries

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); H.M.M. van Beusekom (Heleen); D.S. van Ingen Schenau; R.A. Huijts; J.C.H. Schuurbiers (Johan); W.J. de Klein (Willem); P.W.J.C. Serruys (Patrick); P.D. Verdouw (Pieter); W.J. van der Giessen (Wim)

    1992-01-01

    textabstractA polyethylene-terephthalate braided mesh stent has been developed for application in the (coronary) arterial tree. In vitro measurements showed that the radial pressure delivered by this device was in the same range as that of a stainless steel stent. Hysteresis-like behavior, however,

  17. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    OpenAIRE

    Yilmaz Omur Otlu

    2014-01-01

    A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but ...

  18. Brachial artery injury due to closed posterior elbow dislocation: case report☆

    Directory of Open Access Journals (Sweden)

    Alberto Naoki Miyazaki

    2016-04-01

    Full Text Available An association between closed posterior elbow dislocation and traumatic brachial artery injury is rare. Absence of radial pulse on palpation is an important warning sign and arteriography is the gold-standard diagnostic test. Early diagnosis is essential for appropriate treatment to be provided. This consists of joint reduction and immobilization, along with urgent surgical restoration of arterial flow. Here, a case (novel to the Brazilian literature of an association between these injuries (and the treatment implemented in a 27-year-old male patient is reported. These injuries were sustained through physical assault.

  19. Quantitative determination of arterial wall mechanics with pulse oximetric finger plethysmography.

    Science.gov (United States)

    Kato, R; Sato, J; Iuchi, T; Higuchi, Y

    1999-10-30

    The plethysmographic wave of pulse oximetry reflects arterial pulsation at the fingertip. Since arterial pressure and the pulsatile component of the arterial cross section represent the input and output of the fingertip arterial system, respectively, arterial wall mechanics may be delineated from their relationship. We aimed to construct a mathematical model of the fingertip arterial wall from the relationship between the plethysmographic wave and arterial pressure. The pulse oximetric plethysmographic signal at the forefinger and pressure at the ipsilateral radial artery were measured. Employing the data, simple mathematical models with one to four mechanical elements were tested in terms of the goodness of fit and the physiological implications. The determined model was applied to the data obtained during administration of vasoactive agents in anesthetized patients. The mathematical model suited for describing arterial wall mechanics was a four-element, two-compartment model. The two compartments represent passive mechanical and active contractile properties, respectively. In the application of the model to the anesthetized patients, the vasoactive agents produced changes in the model parameters that implied mechanical alterations in the arterial wall. These findings suggest the benefit of the four-element, two-compartment model in analyzing peripheral vascular wall mechanics influenced by various stimuli in intensive care and anesthesia.

  20. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  1. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  2. Blunt traumatic axillary artery truncation, in the absence of associated fracture.

    Science.gov (United States)

    Bokser, Emily; Caputo, William; Hahn, Barry; Greenstein, Josh

    2018-02-01

    Axillary artery injuries can be associated with both proximal humeral fractures (Naouli et al., 2016; Ng et al., 2016) [1,2] as well as shoulder dislocations (Leclerc et al., 2017; Karnes et al., 2016) [3,4]. We report a rare case of an isolated axillary artery truncation following blunt trauma without any associated fracture or dislocation. A 58-year-old male presented to the emergency department for evaluation after falling on his outstretched right arm. The patient was found to have an absent right radial pulse with decreased sensation to the right arm. Point of care ultrasound showed findings suspicious for traumatic axillary artery injury, and X-rays did not demonstrate any fracture. Computed tomography with angiography confirmed axillary artery truncation with active extravasation. The patient underwent successful vascular repair with an axillary artery bypass. Although extremity injuries are common in emergency departments, emergency physicians need to recognize the risk for vascular injuries, even without associated fracture or dislocation. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

    Directory of Open Access Journals (Sweden)

    Biswajit Majumder

    2016-01-01

    Full Text Available Coronary angiography by right radial artery route using Optitorque Tiger catheter is on the rise given the low rate of local complications and feasibility to perform it as a day-care procedure. We report here a case of coronary angiography performed using Optitorque Tiger catheter (5-French which resulted in a diagnostic error, missing the ostio-proximal left main coronary artery disease which was later detected using EBU 3.5 guide catheter (7-French while performing angioplasty.

  4. Six-year clinical follow-up after treatment of diffuse in-stent restenosis with cutting balloon angioplasty followed by intracoronary brachytherapy with liquid rhenium-188-filled balloon via transradial approach

    International Nuclear Information System (INIS)

    Hang Chiling; Wu Chiungjen; Hsieh Bortsung

    2010-01-01

    Long-term follow-up studies revealed a significant decline in the benefits of intracoronary radiation for in-stent restenosis. A total of 25 study and 25 contemporaneous control patients with diffuse in-stent restenosis who underwent cutting balloon angioplasty (CBA) transradially, followed by subsequent intracoronary irradiation with a liquid β-emitter Rhenium-188 ( 188 Re)-filled balloon were enrolled in the study. The mean clinical follow-up durations were 64.9±13.0 and 66.3±13.8 months for the irradiated and control patients, respectively. Six-month angiographic restenosis was observed in 16% (4 of 25) of the patients in the irradiated group and 48% (12 of 25) of the patients in the control groups (P=0.03). The 6-month major adverse cardiac events (MACE) rate was 12% and 44%, respectively (P=0.025). The 3-year follow-up angiography was performed in 16 of 21 (76%) irradiated patients and in 4 of 13 (31%) control patients who had no significant restenosis at the 6-month angiographic follow-up. Restenosis occurred in 1 of 16 (7%) irradiated patients and 2 of 4 (50%) control patients. Late target lesion revascularization was performed in 1 irradiated and 2 control patients. The MACE rate within 6 years was significantly reduced in the irradiated group (20% vs. 56%, P=0.019). Brachytherapy using 188 Re-filled balloon following CBA for diffuse in-stent restenotic native coronary arteries is effective in reducing target lesion restenosis and improving long-term outcomes. (author)

  5. [Evaluation and Optimization of Microvascular Arterial Anastomoses by Transit Time Flow Measurement].

    Science.gov (United States)

    Herberhold, S; Röttker, J; Bartmann, D; Solbach, A; Keiner, S; Welz, A; Bootz, F; Laffers, W

    2016-03-01

    INDRODUCTION: The regular application of transit time flow measurement in microvascular anastomoses during heart surgery has lead to improvements of the outcome of coronary artery bypass grafts. Our study was meant to discover whether this measurement method was also applicable for evaluation and optimization of microvascular arterial anastomoses of radial forearm flaps. In this prospective examination a combining ultrasound imaging and transit time flow measurement device (VeriQ, MediStim) was used during surgery to assess anastomotic quality of 15 radial forearm flaps. Pulsatility index (PI) and mean blood flow were measured immediately after opening the arterial anastomosis as well as 15 min afterwards. Furthermore, application time and description of handling were recorded seperately for every assessment. Mean blood flow immediately after opening the anastomosis and 15 min later were 3.9 and 3.4 ml/min resepectively showing no statistically significant difference (p=0.96). There was no significance in the increase of pulsatility index from 22.1 to 27.2 (p=0.09) during the same time range, either. Due to measurement results showing atypical pulse curves in 2 cases decision for surgical revision of the anastomoses was made. All forearm flaps showed good vascularisation during follow-up. Time for device set up, probe placement and measurements was about 20 min. Handling was described to be uncomplicated without exception. There were no noteworthy problems. Transit time flow measurement contributes to the improvement of anastomotic quality and therefore to the overall outcome of radial forearm flaps. The examined measurement method provides objective results and is useful for documentation purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  6. Heart transplantation and arterial elasticity

    Directory of Open Access Journals (Sweden)

    Colvin-Adams M

    2013-12-01

    Full Text Available Monica Colvin-Adams,1 Nonyelum Harcourt,1 Robert LeDuc,2 Ganesh Raveendran,1 Yassir Sonbol,3 Robert Wilson,1 Daniel Duprez11Cardiovascular Division, University of Minnesota, Minneapolis, MN, USA; 2Division of Biostatistics University of Minnesota, Minneapolis, MN, USA; 3Cardiovascular Division, St Luke's Hospital System, Sugar Land, TX, USAObjective: Arterial elasticity is a functional biomarker that has predictive value for cardiovascular morbidity and mortality in nontransplant populations. There is little information regarding arterial elasticity in heart transplant recipients. This study aimed to characterize small (SAE and large (LAE artery elasticity in heart transplant recipients in comparison with an asymptomatic population free of overt cardiovascular disease. A second goal was to identify demographic and clinical factors associated with arterial elasticity in this unique population.Methods: Arterial pulse waveform was registered noninvasively at the radial artery in 71 heart transplant recipients between 2008 and 2010. SAEs and LAEs were derived from diastolic pulse contour analysis. Comparisons were made to a healthy cohort of 1,808 participants selected from our prevention clinic database. Multiple regression analyses were performed to evaluate associations between risk factors and SAE and LAE within the heart transplant recipients.Results: LAE and SAE were significantly lower in heart transplant recipients than in the normal cohort (P <0.01 and P < 0.0001, respectively. Female sex and history of ischemic cardiomyopathy were significantly associated with reduced LAE and SAE. Older age and the presence of moderate cardiac allograft vasculopathy were also significantly associated with reduced SAE. Transplant duration was associated with increased SAE.Conclusion: Heart transplants are associated with peripheral endothelial dysfunction and arterial stiffness, as demonstrated by a significant reduction in SAE and LAE when compared with a

  7. Perceptions of advantages and barriers to radial-access percutaneous coronary intervention in VA cardiac catheterization laboratories.

    Science.gov (United States)

    Helfrich, Christian D; Tsai, Thomas T; Rao, Sunil V; Lemon, Jaclyn M; Eugenio, Evercita C; Vidovich, Mladen I; Shroff, Adhir R; Speiser, Bernadette S; Bryson, Chris L

    2014-01-01

    Compared with trans-femoral percutaneous coronary intervention (TFI), trans-radial PCI (TRI) has a lower risk of bleeding, access site complications and hospital costs, and is preferred by patients. However, TRI accounts for a minority of PCIs in the US, and there is currently little research that explores why. We conducted a national survey in February 2013 to assess perceptions of TRI vs. TFI, and barriers to TRI adoption and implementation among interventional cardiologists employed by the US Veterans Health Administration (VHA), and linked these data to site-level TRI annual rates for 2013. We received 78 completed surveys (32% response rate). Respondents at sites that perform few or no TRIs identified increased radiation exposure as the greatest barrier while at sites that perform a high percentage of TRIs respondents identified the steep learning curve as the greatest barrier. Majorities of survey respondents at all sites rated TRI as superior on 5 of 7 criteria, including patient comfort and bleeding complications, but rated TFI as superior on procedure time and procedure success. Even interventional cardiologists at sites that perform few or any TRIs recognized the superiority of TRI for patient comfort and safety, but rated it inferior to TFI on procedure time and technical results. Interventional cardiologists at high-TRI labs rated TRI as equivalent on procedure time and technical results. Efforts to increase TRI adoption and implementation may be more successful if they emphasize that procedure times and technical results depend on achieving proficiency. Published by Elsevier Inc.

  8. Validation of a non-invasive arterial monitor GATE model for PET

    Energy Technology Data Exchange (ETDEWEB)

    Giansiracusa, P.J., E-mail: pgia@student.unimelb.edu.au [School of Physics, The University of Melbourne, Parkville (Australia); Peake, D.J. [DETECT Australia, Bundoora (Australia); Sobott, B.A. [School of Physics, The University of Melbourne, Parkville (Australia); O' Keefe, G. [The Austin PET Centre, Austin Hospital, Heidelberg (Australia); Rassool, R.P. [School of Physics, The University of Melbourne, Parkville (Australia)

    2014-02-11

    The Non-Invasive Arterial Monitor (NIAM3) is an SiPM based detector system designed for calibrating Positron-Emission Tomography (PET) images without invasive blood sampling. By imaging the radial and ulnar arteries in the wrist directly with a custom built PET system the resultant PET images can be calibrated. An integral step in the development of a complex detector system is the creation of a model which accurately reflects the physical reality being studied. This paper describes the development of a simulation for NIAM which shows good agreement between the model and physical detector setup.

  9. Association of clinical androgen excess with radial artery intima media thickness in women with polycystic ovary syndrome.

    Science.gov (United States)

    Yilmaz, S A; Kebapcilar, A; Koplay, M; Kerimoglu, O S; Pekin, A T; Gencoglu, B; Dogan, N U; Celik, C

    2015-06-01

    This study explores the relationship between clinical cardiovascular risk factors and clinical androgen excess, with direct comparison to radial artery intima media thickness (rIMT). rIMT of 91 patients with polycystic ovary syndrome (PCOS) were compared with 72 healthy women. Patients were divided into three groups with regard to body mass index (BMI). Group1 = 56 women (31 controls and 25 PCOS) with low BMI(18-22.49 kg/m(2)), Group2 = 36 women (15 controls and 21 PCOS) with normal BMI (22.5-24.99 kg/m(2)) and Group3 = 71 women (26 controls and 45 PCOS) with high BMI (25-30 kg/m(2)). rIMT was significantly higher in patients with PCOS (p = 0.007). rIMT was significantly higher group1 and group3 in patients with PCOS compared to controls (p = 0.007 and p = 0.042, respectively). There was a significant positive association between rIMT levels and fT in women with PCOS in group1 (r = 0.24, p = 0.04). rIMT levels correlated to fT levels in women with PCOS in group3 (r = 0.32, p = 0.03). Modified Ferriman-Gallwey (mFG) scores demonstrated a positive association with free testosterone, total testosterone, free androgen index, waist circumference (WC), LH levels, insulin levels, Homeostasis Model Assessment index(HOMA-IR), rIMT and a negative correlation with sex hormone binding globulin in group1 and group2. mFG scores demonstrated a positive association with free testosterone (r = 0.33, p = 0.029) in group3, but no association was found between mFG and WC, HOMA-IR in group3. Our findings indicate that clinical androgen excess may be associated with cardiovascular disease in patients with PCOS.

  10. Complications of operative treatment of injuries of peripheral arteries.

    Science.gov (United States)

    Velinovic, M M; Davidovic, B L; Lotina, I S; Vranes, R M; Djukic, L P; Arsov, J V; Ristic, V M; Kocica, J M; Petrovic, L P

    2000-06-01

    In 1991 and 1992, a total of 97 patients with 106 peripherial arterial injuries underwent surgery at the Institute for Cardiovascular Diseases, Clinical Centre of Serbia. Civilian injuries accounted for 53 (54.6%) patients (94.3% males, age range: 16-63 yr, mean: 35.2), and 44 patients had war injuries (93.2% males, age range: 19-61 yr, mean: 34.8). The injuries affected the superfitial femoral artery in 31 (29.24%); the popliteal artery in 28 (26.41%); the brachial artery in 17 (16.04%); the posterior tibial artery in 6 (5.66%); the axillary artery in 5 (4.72%); the anterior tibial artery in 5 (4.72%); the tibioperoneal trunk in 4 (3. 77%); the common femoral artery in 4 (3.77%); the external iliac artery in 2 (1.89%); the profound femoral artery in 2 (1.89%); the radial artery in 1 (0.94%); and ulnar artery in 1 (0.94%).A total of 98 reconstructive procedures were used to treat these patients. Graft interposition carried out in 50 (51.02%); by pass in 25 (25. 51%); end-to-end anastomosis in 9 (9.18%); suture in 8 (8.16%); ligation in 4 (4.08%); and patch-angioplasty in 2 (2.04%). Primary reconstruction of injured arteries was performed in 72.2% and secondary repair in 27.8% cases. Infection developed in 51 (52.57%) patients, and it was significantly (P<0.05) more common in the war injuries (70.45%) and in secondary repairs (88.89%). The presence of associated lesions (69.56%) was also correlated with a greater rate of infection. Amputation was necessary in 21 (21.65%) of our patients, and was significantly (P<0.05) more often performed after secondary (44.44%) than primary operations (12.86%) and in the presence of associated injuries (32.61%).

  11. Percutaneous brachial artery catheterization for coronary angiography and percutaneous coronary interventions (pci): an encouraging experience of 100 cases

    International Nuclear Information System (INIS)

    Islam, Z.U.; Maken, G.R.; Saif, M.; Khattak, Z.A.

    2013-01-01

    Objective: To evaluate the practicability and safety of the percutaneous transbrachial approach (TBA) for diagnostic coronary angiography and therapeutic percutaneous coronary interventions. Study Design: Quasi experimental study. Place and Duration of Study: The study was carried out in Armed Forces Institute of Cardiology- National Institute of Heart Diseases (AFIC-NIHD) from March 2009 to May 2011. Patients and Methods: We collected data of 100 consecutive patients who underwent coronary catheterization by the percutaneous transbrachial approach. Transbrachial catheterization was performed only if the radial access failed or radial pulse was feeble. Study endpoints included successful brachial artery catheterization, vascular and neurological complications at access site and procedure success rate. Results: Mean age of the patients was 54 years (range 33-79 yrs) and 65(65%) were males and 35 (35%) were females. The right brachial artery was used in all of the cases. Procedural success was achieved in 100% of the patients. Coronary angiography was performed in 70 patients and percutaneous coronary interventions were done in 30 cases. Out of these 30 cases, PCI to left coronary arteries (LAD and LCX) were performed in 19 patients while 11 patients had PCI to right coronary artery (RCA). No case of vascular complications such as major access site bleeding, vascular perforation, brachial artery occlusion causing forearm ischemia, compartment syndrome, vascular spasm or failure to catheterize coronary arteries requiring alternate vascular access were observed. Conclusion: Brachial artery is a safe and easily accessible approach for coronary angiography and percutaneous coronary interventions. (author)

  12. Modulation of radial blood flow during Braille character discrimination task.

    Science.gov (United States)

    Murata, Jun; Matsukawa, K; Komine, H; Tsuchimochi, H

    2012-03-01

    Human hands are excellent in performing sensory and motor function. We have hypothesized that blood flow of the hand is dynamically regulated by sympathetic outflow during concentrated finger perception. To identify this hypothesis, we measured radial blood flow (RBF), radial vascular conductance (RVC), heart rate (HR), and arterial blood pressure (AP) during Braille reading performed under the blind condition in nine healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 30 s by the forefinger, and to touch a blank plate as control for the Braille discrimination procedure. HR and AP slightly increased during Braille reading but remained unchanged during the touching of the blank plate. RBF and RVC were reduced during the Braille character discrimination task (decreased by -46% and -49%, respectively). Furthermore, the changes in RBF and RVC were much greater during the Braille character discrimination task than during the touching of the blank plate (decreased by -20% and -20%, respectively). These results have suggested that the distribution of blood flow to the hand is modulated via sympathetic nerve activity during concentrated finger perception.

  13. The Infrapopliteal Arterial Occlusions Similar to Buerger Disease: Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Kimihiro Igari

    2014-01-01

    Full Text Available We herein present two cases that required the differential diagnosis of Buerger disease. Case 1 involved a 55-year-old male with a smoking habit who was admitted with ulcers and coldness in his fingers and toes. Angiography showed blockage in both the radial and posterior tibial arteries, which led to an initial diagnosis of Buerger disease. However, a biopsy of the right posterior tibial artery showed pathological findings of fibromuscular dysplasia (FMD. Case 2 involved a 28-year-old male with intermittent claudication who was examined at another hospital. Angiography showed occlusion of both popliteal and crural arteries, and the patient was suspected to have Buerger disease. However, computed tomography disclosed an abnormal slip on both sides of the popliteal fossa, and we diagnosed him with bilateral popliteal artery entrapment syndrome (PAES. These cases illustrate that other occlusive diseases, such as FMD and PAES, may sometimes be misdiagnosed as Buerger disease.

  14. Non Newtonian Behavior of Blood in Presence of Arterial Occlusion

    OpenAIRE

    Dr.Arun Kumar Maiti

    2016-01-01

    The objective of the present numerical model is to investigate the effect of shape of stenosis on blood flow through an artery using Bingham plastic fluid model. Blood is modeled as Bingham plastic fluid in a uniform circular tube with an axially symmetric but radially non symmetric stenosis. The expressions for flux, dimensionless resistance to flow with stenosis shape parameter, stenosis length and stenosis size have been shown graphically

  15. Técnica para retirada da artéria radial sem utilização de clipes hemostáticos e experiência clínica Radial artery harvesting technique without hemostatic clips and clinical experience

    Directory of Open Access Journals (Sweden)

    João Bosco de Oliveira

    2008-03-01

    Full Text Available OBJETIVO: As diferentes técnicas de dissecção de artéria radial (AR obtêm resultados semelhantes. Estas técnicas utilizam eletrocautério, bisturi ultra-sônico ou tesouras em diferentes combinações, mas geralmente associadas ao uso de clipes hemostáticos. Este trabalho descreve uma técnica de dissecção de AR com a combinação de tesouras e eletrocautério sem o uso de clipes hemostáticos. MÉTODOS: O estudo apresenta um levantamento retrospectivo de 107 pacientes, entre 28 e 78 anos (média ± desvio padrão 53,3 ± 8 anos, feito entre janeiro de 2000 e junho de 2005, no qual é relatada a incidência de sangramento, reoperação, infarto do miocárdio e mortalidade. RESULTADOS: Não ocorreram sangramentos relacionados à AR e não ocorreram reoperações. Ocorreram três (2,8% infartos possivelmente relacionados ao território de anastomose de AR. A mortalidade foi de 0,9% não relacionada a causas cardiovasculares. CONCLUSÃO: A dissecção de AR com eletrocautério sem clipes hemostáticos não apresentou sangramento, foi de baixo custo e dispensa investimentos em equipamentos adicionais.OBJECTIVE: The various techniques of radial artery (RA harvesting produce similar results. These techniques use electrocautery, ultrasonic scalpel, or sharp scissors in different combinations, but usually associated with the use of hemostatic clips. We describe a RA harvesting technique with the combination of sharp scissors and electrocautery without the use of hemostatic clips. METHODS: We describe a retrospective study of 107 patients ranging from 28 and 78 years of age (mean ± SD; 53.3 ± 8 yrs. Bleeding, re-operation, infarct, and death were analyzed. RESULTS: No bleeding was imputable to the RA and no re-operations were required. There were three (2.8% infarcts possibly related to the RA anastomosis territory. Mortality was 0.9%, but unrelated to cardiac complications. CONCLUSION: RA electrocautery harvesting without hemostatic clips

  16. Experimental exposure to diesel exhaust increases arterial stiffness in man

    Directory of Open Access Journals (Sweden)

    Newby David E

    2009-03-01

    Full Text Available Abstract Introduction Exposure to air pollution is associated with increased cardiovascular morbidity, although the underlying mechanisms are unclear. Vascular dysfunction reduces arterial compliance and increases central arterial pressure and left ventricular after-load. We determined the effect of diesel exhaust exposure on arterial compliance using a validated non-invasive measure of arterial stiffness. Methods In a double-blind randomized fashion, 12 healthy volunteers were exposed to diesel exhaust (approximately 350 μg/m3 or filtered air for one hour during moderate exercise. Arterial stiffness was measured using applanation tonometry at the radial artery for pulse wave analysis (PWA, as well as at the femoral and carotid arteries for pulse wave velocity (PWV. PWA was performed 10, 20 and 30 min, and carotid-femoral PWV 40 min, post-exposure. Augmentation pressure (AP, augmentation index (AIx and time to wave reflection (Tr were calculated. Results Blood pressure, AP and AIx were generally low reflecting compliant arteries. In comparison to filtered air, diesel exhaust exposure induced an increase in AP of 2.5 mmHg (p = 0.02 and in AIx of 7.8% (p = 0.01, along with a 16 ms reduction in Tr (p = 0.03, 10 minutes post-exposure. Conclusion Acute exposure to diesel exhaust is associated with an immediate and transient increase in arterial stiffness. This may, in part, explain the increased risk for cardiovascular disease associated with air pollution exposure. If our findings are confirmed in larger cohorts of susceptible populations, this simple non-invasive method of assessing arterial stiffness may become a useful technique in measuring the impact of real world exposures to combustion derived-air pollution.

  17. Regression analysis of radial artery pulse palpation as a potential tool for traditional Chinese medicine training education.

    Science.gov (United States)

    Huang, Po-Yu; Lin, Wen-Chen; Chiu, Bill Yuan-Chi; Chang, Hen-Hong; Lin, Kang-Ping

    2013-12-01

    Pulse palpation was an important part of the traditional Chinese medicine (TCM) vascular examination. It is challenging for new physicians to learn to differentiate between palpations of various pulse types, due to limited comparative learning time with established masters, and so normally it takes many years to master the art. The purpose of this study was to introduce an offline TCM skill evaluation and comparison system that makes available learning of palpation without the master's presence. We record patient's radial artery pulse using an existing pressure-based pulse acquisition system, then annotate it with teachers' evaluation when palpating the same patient, assigned as likelihood of it being each pulse type, e.g. wiry, slippery, hesitant. These training data were separated into per-doctor and per-skill databases for evaluation and comparison purposes, using the following novel procedure: each database was used as training data to a panel of time-series data-mining algorithms, driven by two validation tests, with the created training models evaluated in mean-squared-error. Each validation of the panel and training data yielded an array of error terms, and we chose one to quantitatively evaluate palpation techniques, giving way to compute self consistency and mutual-similarity across different practitioners and techniques. Our experiment of two practitioners and 396 per-processing samples yielded the following: one of the physicians has much higher value of self-consistency for all tested pulse types. Also, the two physicians have high similarity in how they palpate the slipper pulse (P) type, but very dissimilar for hesitant (H) type. This system of skill comparisons may be more broadly applied in places where supervised learning algorithms can detect and use meaningful features in the data; we chose a panel of algorithms previously shown to be effective for many time-series types, but specialized algorithms may be added to improve feature-specific aspect

  18. Relación entre el envejecimiento y la morfología de los registros de variación de diámetro arterial: clasificación con redes neuronales artificiales

    Directory of Open Access Journals (Sweden)

    Fernando M. Clara

    2005-01-01

    Full Text Available Relation between Aging and the Morphology of Radial Artery Diameter Variation Registers: Classification Using Artificial Neural Networks Aníbal R. Introzzi, Lucía I. Passoni, Adriana G. Scandurra, Gustavo J. Meschino, Fernando M. Clara The aim of this study was to assess the modification of the radial artery diameter variation signal in accordance with aging. The signal was registered via an acquisition system using a capacitive transducer leaning on the skin at the level of the radial artery. In order to assess the relation between loss of distensibility and signal modifications due to aging, the experiment was carried out on a group of 64 normotensive subjects: 20 youths, 24 adults and 20 elderly men. Morphological descriptive parameters were obtained and the potentiality to classify the arterial diameter variation waves according to aging was evaluated with a Kohonen artificial neural network. Signal analysis processing revealed the presence of three constituent waves: two systolic waves, first and second, and a diastolic wave. Aging produces important changes in signal conformation, such as expansion of the first systolic wave, decrease of the diastolic wave amplitude and rise of the second systolic wave approaching and overlapping the vertex of the first systolic wave. The artificial neural network correctly classified the 64 registrations, locating them in their corresponding age cluster. Considering the absence of illness in the sample subjects, the existence of a healthy arterial aging pattern is revealed. This system could be able to detect early evidence of arterial pathology development involving an increment of arterial stiffness with a loss of compliance (sclerosis, hypertension.

  19. Antiproton compression and radial measurements

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Funakoshi, R; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jenkins, M J; Jorgensen, L V; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Page R D; Povilus, A; Pusa, P; Robicheaux, F; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; Van der Werf, D P; Wurtele, J S; Yamazaki, Y

    2008-01-01

    Control of the radial profile of trapped antiproton clouds is critical to trapping antihydrogen. We report detailed measurements of the radial manipulation of antiproton clouds, including areal density compressions by factors as large as ten, achieved by manipulating spatially overlapped electron plasmas. We show detailed measurements of the near-axis antiproton radial profile, and its relation to that of the electron plasma. We also measure the outer radial profile by ejecting antiprotons to the trap wall using an octupole magnet.

  20. 'Generalizability' of a radial-aortic transfer function for the derivation of central aortic waveform parameters.

    Science.gov (United States)

    Hope, Sarah A; Meredith, Ian T; Tay, David; Cameron, James D

    2007-09-01

    Arterial transfer functions (TFs) describe the relationship between the pressure waveform at different arterial sites. Generalized TFs are used to reconstruct central aortic waveforms from non-invasively obtained peripheral waveforms and have been promoted as potentially clinically useful. A limitation is the paucity of information on their 'generalizability' with no information existing on the number of subjects required to construct a satisfactory TF, nor is adequate prospective validation available. We therefore investigated the uniformity of radial-aortic TFs and prospectively estimated the capacity of a generalized TF to reconstruct individual central blood pressure parameters. Ninety-three subjects (64 male) were studied by simultaneous radial applanation and high-fidelity (Millar Mikro-tip catheter) direct measurement of central aortic BP during elective coronary procedures. Subjects were prospectively randomized to either a derivation or validation group. Increasing numbers of individual TFs from the derivation group were averaged to form a generalized TF. There was minimal change with greater than 20 TFs averaged. In the validation group, the error in most reconstructed parameters related to the absolute value of the directly measured parameter [systolic blood pressure (SBP) and pulse pressure, Pcentral aortic SBP and pulse pressure (negatively) and time to peak systole (positively) (all PInclusion of more than 20 individual TFs in the construction of a generalized TF does not improve 'generalizability'. There appear to be systematic errors in derived central pressure waveforms and derived aortic augmentation index is inaccurate compared to the directly measured value.

  1. Thrombosed persistent median artery causing carpal tunnel syndrome associated with bifurcated median nerve: A case report

    International Nuclear Information System (INIS)

    Salter, M.; Sinha, N. R.; Szmigielski, W.

    2011-01-01

    Background: Carpal tunnel syndrome is a sporadically occurring abnormality due to compression of median nerve. It is exceedingly rare for it to be caused by thrombosis of persistent median artery. Case Report: A forty two year old female was referred for ultrasound examination due to ongoing wrist pain, not relived by pain killers and mild paraesthesia on the radial side of the hand. High resolution ultrasound and Doppler revealed a thrombosed persistent median artery and associated bifurcated median nerve. The thrombus resolved on treatment with anticoagulants. Conclusions: Ultrasound examination of the wrist when done for patients with carpal tunnel syndrome should preferably include looking for persistent median artery and its patency. (authors)

  2. Aerobic exercise training reduces arterial stiffness in metabolic syndrome.

    Science.gov (United States)

    Donley, David A; Fournier, Sara B; Reger, Brian L; DeVallance, Evan; Bonner, Daniel E; Olfert, I Mark; Frisbee, Jefferson C; Chantler, Paul D

    2014-06-01

    The metabolic syndrome (MetS) is associated with a threefold increase risk of cardiovascular disease (CVD) mortality partly due to increased arterial stiffening. We compared the effects of aerobic exercise training on arterial stiffening/mechanics in MetS subjects without overt CVD or type 2 diabetes. MetS and healthy control (Con) subjects underwent 8 wk of exercise training (ExT; 11 MetS and 11 Con) or remained inactive (11 MetS and 10 Con). The following measures were performed pre- and postintervention: radial pulse wave analysis (applanation tonometry) was used to measure augmentation pressure and index, central pressures, and an estimate of myocardial efficiency; arterial stiffness was assessed from carotid-femoral pulse-wave velocity (cfPWV, applanation tonometry); carotid thickness was assessed from B-mode ultrasound; and peak aerobic capacity (gas exchange) was performed in the seated position. Plasma matrix metalloproteinases (MMP) and CVD risk (Framingham risk score) were also assessed. cfPWV was reduced (P Exercise training reduced (P exercise training, thereby lowering their cardiovascular risk. Copyright © 2014 the American Physiological Society.

  3. Vascular patterns of upper limb: an anatomical study with accent on superficial brachial artery

    Directory of Open Access Journals (Sweden)

    David Kachlik

    2011-02-01

    Full Text Available The aim of the study was to evaluate the terminal segmentation of the axillary artery and to present four cases of anomalous branching of the axillary artery, the superficial brachial artery (arteria brachialis superficialis, which is defined as the brachial artery that runs superficially to the median nerve. Totally, 130 cadaveric upper arms embalmed by classical formaldehyde technique from collections of the Department of Anatomy, Third Faculty of Medicine, Charles University in Prague, were macroscopically dissected with special focus on the branching arrangement of the axillary artery. The most distal part of the axillary artery (infrapectoral part terminated in four cases as a bifurcation into two terminal branches: the superficial brachial artery and profunda brachii artery, denominated according to their relation to the median nerve. The profunda brachii artery primarily gave rise to the main branches of the infrapectoral part of the axillary artery. The superficial brachial artery descended to the cubital fossa where it assumed the usual course of the brachial artery in two cases and in the other two cases its branches (the radial and ulnar arteries passed superficially to the flexors. The incidence of the superficial brachial artery in our study was 5% of cases. The reported incidence is a bit contradictory, from 0.12% to 25% of cases. The anatomical knowledge of the axillary region is of crucial importance for neurosurgeons and specialists using the radiodiagnostic techniques, particularly in cases involving traumatic injuries. The improved knowledge would allow more accurate diagnostic interpretations and surgical treatment.

  4. Stability of radial swirl flows

    International Nuclear Information System (INIS)

    Dou, H S; Khoo, B C

    2012-01-01

    The energy gradient theory is used to examine the stability of radial swirl flows. It is found that the flow of free vortex is always stable, while the introduction of a radial flow will induce the flow to be unstable. It is also shown that the pure radial flow is stable. Thus, there is a flow angle between the pure circumferential flow and the pure radial flow at which the flow is most unstable. It is demonstrated that the magnitude of this flow angle is related to the Re number based on the radial flow rate, and it is near the pure circumferential flow. The result obtained in this study is useful for the design of vaneless diffusers of centrifugal compressors and pumps as well as other industrial devices.

  5. Improving the Robustness of Real-Time Myoelectric Pattern Recognition against Arm Position Changes in Transradial Amputees

    Directory of Open Access Journals (Sweden)

    Yanjuan Geng

    2017-01-01

    Full Text Available Previous studies have showed that arm position variations would significantly degrade the classification performance of myoelectric pattern-recognition-based prosthetic control, and the cascade classifier (CC and multiposition classifier (MPC have been proposed to minimize such degradation in offline scenarios. However, it remains unknown whether these proposed approaches could also perform well in the clinical use of a multifunctional prosthesis control. In this study, the online effect of arm position variation on motion identification was evaluated by using a motion-test environment (MTE developed to mimic the real-time control of myoelectric prostheses. The performance of different classifier configurations in reducing the impact of arm position variation was investigated using four real-time metrics based on dataset obtained from transradial amputees. The results of this study showed that, compared to the commonly used motion classification method, the CC and MPC configurations improved the real-time performance across seven classes of movements in five different arm positions (8.7% and 12.7% increments of motion completion rate, resp.. The results also indicated that high offline classification accuracy might not ensure good real-time performance under variable arm positions, which necessitated the investigation of the real-time control performance to gain proper insight on the clinical implementation of EMG-pattern-recognition-based controllers for limb amputees.

  6. Foster replantation of fingertip using neighbouring digital artery in a young child.

    Science.gov (United States)

    Xu, Jing-Hong; Gao, Zheng-Jun; Yao, Jing-Ming; Tan, Wei-Qiang; Dawreeawo, Javed

    2010-06-01

    Reconstruction of an amputated fingertip in a young child demands special techniques for success. We report a 2.5-year-old female patient with an amputated left index fingertip with the vascular defect being too severe to perform the usual replantation. Comparing several methods, we used the neighbouring digital artery as the feeding artery to perform foster replantation. Finally, the patient was satisfied with the appearance and function of her fingers. The clinical case, techniques, results are described and discussed. We consider it a useful technique, especially for those with a rather severe vascular defect. A 2.5-year-old girl suffered a crush amputation of the left index fingertip. Only the flexor tendon of the amputated fingertip was connected to the proximal finger tissue and the blood supply was completely lost (Figure 1). The distal amputated fingertip was fixed using Kirschner wire under general anaesthesia. Then, microsurgery operation was carried out immediately to replant this amputated fingertip. Both ulnar and radial digital arteries were avulsed, while the dorsal vein was intact and the digital nerve was also surviving. The integrity of blood vessels was too traumatised to connect to the proximal part. In the case of the distal part of the ulnar artery of the injured index finger, the blood supply was established by anastomosing the distal end of the amputated tip and the radial artery of the middle finger, which was the feeding artery (Figure 2). A 11/0 nylon suture was used. The dorsal vein and digital nerve were repaired by means of microsurgical anastomosis. The wound was covered with the dorsal skin of the middle finger and the palmar skin of the index finger to form a skin pedicle, and then, immobility of the two fingers was maintained to prevent avulsion. The index tip obtained good blood supply and survived completely (Figure 3). Detachment of the index and middle finger was performed after 3 weeks, and both of the fingers showed good

  7. A new noninvasive device for continuous arterial blood pressure monitoring in the superficial temporal artery

    International Nuclear Information System (INIS)

    Chin, K Y; Panerai, R B

    2013-01-01

    Continuous recording of arterial blood pressure (ABP) has many applications in cardiovascular physiology, but existing alternatives rely on measurements performed in the fingers or radial artery. Peripheral recordings have significant differences from central ABP regarding the pattern of the waveform and corresponding systolic and diastolic values. To address the need for noninvasive measurements closer to the ascending aorta, a new device was constructed to measure ABP in the superficial temporal artery (STA) using photoplethysmography and the arterial volume clamping technique. The optoelectronic circuitry to generate the photoplethysmogram is contained in a specially designed probe placed over the STA and kept in place with a head frame. The prototype (STAbp) also includes original designs for the pneumatic, electronic, signal processing, control and display sub-systems. A self-calibration feature regularly updates the photoplethysmogram operating point to improve accuracy. The performance of the STAbp was compared against the Finapres in 19 healthy subjects. At rest, the bias (SD d ) was −23.1 (15.05), −10.8 (13.83) and −12.4 (12.93) mmHg for systolic, mean and diastolic pressures respectively, without significant differences in drift between the two devices. The 99% bandwidth (SD) for the spectral distribution of ABP waveforms was 5.3 (1.46) Hz for STAbp and 6.8 (0.73) Hz for the Finapres (p < 0.01). Handgrip manoeuvre showed a very similar response to the Finapres, including the rapid return to baseline on release. The new STAbp device has considerable potential as a new tool for clinical and research applications where continuous recording of more central ABP is advantageous compared to peripheral alternatives. (paper)

  8. [Comparison of chemical quality characteristics between radial striations and non-radial striations in tuberous root of Rehmannia glutinosa].

    Science.gov (United States)

    Xie, Cai-Xia; Zhang, Miao; Li, Ya-Jing; Geng, Xiao-Tong; Wang, Feng-Qing; Zhang, Zhong-Yi

    2017-11-01

    An HPLC method was established to determine the contents of catalpol, acteoside, rehmaionoside A, rehmaionoside D, leonuride in three part of Rehmanni glutinosa in Beijing No.1 variety R. glutinosa during the growth period, This method, in combination with its HPLC fingerprint was used to evaluate its overall quality characteristics.The results showed that:① the content of main components of R. glutinosa varied in different growth stages ;② there was a great difference of the content of main components between theradial striations and the non-radial striations; ③ the two sections almost have the same content distribution of catalpol, acteoside and rehmaionoside D; ④the content of rehmaionoside A in non-radial striations was higher than that in radial striations,while the content of leonuride in radial striations was higher than that in non-radial striations.; ⑤the HPLC fingerprint of radial striations, non-radial striations and whole root tuber were basically identical, except for the big difference in the content of chemical components. The result of clustering displayed that the radial striations, non-radial striations, and whole root were divided into two groups. In conclusion, there was a significant difference in the quality characteristics of radial striations and non-radial striations of R. glutinosa. This research provides a reference for quality evaluation and geoherbalism of R. glutinosa. Copyright© by the Chinese Pharmaceutical Association.

  9. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  10. Arterial wave reflection and subclinical left ventricular systolic dysfunction.

    Science.gov (United States)

    Russo, Cesare; Jin, Zhezhen; Takei, Yasuyoshi; Hasegawa, Takuya; Koshaka, Shun; Palmieri, Vittorio; Elkind, Mitchell Sv; Homma, Shunichi; Sacco, Ralph L; Di Tullio, Marco R

    2011-03-01

    Increased arterial wave reflection is a predictor of cardiovascular events and has been hypothesized to be a cofactor in the pathophysiology of heart failure. Whether increased wave reflection is inversely associated with left-ventricular (LV) systolic function in individuals without heart failure is not clear. Arterial wave reflection and LV systolic function were assessed in 301 participants from the Cardiovascular Abnormalities and Brain Lesions (CABL) study using two-dimensional echocardiography and applanation tonometry of the radial artery to derive central arterial waveform by a validated transfer function. Aortic augmentation index (AIx) and wasted energy index (WEi) were used as indices of wave reflection. LV systolic function was measured by LV ejection fraction (LVEF) and tissue Doppler imaging (TDI). Mitral annulus peak systolic velocity (Sm), peak longitudinal strain and strain rate were measured. Participants with history of coronary artery disease, atrial fibrillation, LVEF less than 50% or wall motion abnormalities were excluded. Mean age of the study population was 68.3 ± 10.2 years (64.1% women, 65% hypertensive). LV systolic function by TDI was lower with increasing wave reflection, whereas LVEF was not. In multivariate analysis, TDI parameters of LV longitudinal systolic function were significantly and inversely correlated to AIx and WEi (P values from 0.05 to 0.002). In a community cohort without heart failure and with normal LVEF, an increased arterial wave reflection was associated with subclinical reduction in LV systolic function assessed by novel TDI techniques. Further studies are needed to investigate the prognostic implications of this relationship.

  11. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    Science.gov (United States)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was

  12. Radial Artery Catheterization

    Science.gov (United States)

    ... Circulation My alerts Sign In Join Sign out Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  13. Physical mechanism determining the radial electric field and its radial structure in a toroidal plasma

    International Nuclear Information System (INIS)

    Ida, Katsumi; Miura, Yukitoshi; Itoh, Sanae

    1994-10-01

    Radial structures of plasma rotation and radial electric field are experimentally studied in tokamak, heliotron/torsatron and stellarator devices. The perpendicular and parallel viscosities are measured. The parallel viscosity, which is dominant in determining the toroidal velocity in heliotron/torsatron and stellarator devices, is found to be neoclassical. On the other hand, the perpendicular viscosity, which is dominant in dictating the toroidal rotation in tokamaks, is anomalous. Even without external momentum input, both a plasma rotation and a radial electric field exist in tokamaks and heliotrons/torsatrons. The observed profiles of the radial electric field do not agree with the theoretical prediction based on neoclassical transport. This is mainly due to the existence of anomalous perpendicular viscosity. The shear of the radial electric field improves particle and heat transport both in bulk and edge plasma regimes of tokamaks. (author) 95 refs

  14. Perceptions of advantages and barriers to radial-access percutaneous coronary intervention in VA cardiac catheterization laboratories

    International Nuclear Information System (INIS)

    Helfrich, Christian D.; Tsai, Thomas T.; Rao, Sunil V.; Lemon, Jaclyn M.; Eugenio, Evercita C.; Vidovich, Mladen I.; Shroff, Adhir R.; Speiser, Bernadette S.; Bryson, Chris L.

    2014-01-01

    Background/Purpose: Compared with trans-femoral percutaneous coronary intervention (TFI), trans-radial PCI (TRI) has a lower risk of bleeding, access site complications and hospital costs, and is preferred by patients. However, TRI accounts for a minority of PCIs in the US, and there is currently little research that explores why. Methods/Material: We conducted a national survey in February 2013 to assess perceptions of TRI vs. TFI, and barriers to TRI adoption and implementation among interventional cardiologists employed by the US Veterans Health Administration (VHA), and linked these data to site-level TRI annual rates for 2013. Results: We received 78 completed surveys (32% response rate). Respondents at sites that perform few or no TRIs identified increased radiation exposure as the greatest barrier while at sites that perform a high percentage of TRIs respondents identified the steep learning curve as the greatest barrier. Majorities of survey respondents at all sites rated TRI as superior on 5 of 7 criteria, including patient comfort and bleeding complications, but rated TFI as superior on procedure time and procedure success. Conclusions: Even interventional cardiologists at sites that perform few or any TRIs recognized the superiority of TRI for patient comfort and safety, but rated it inferior to TFI on procedure time and technical results. Interventional cardiologists at high-TRI labs rated TRI as equivalent on procedure time and technical results. Efforts to increase TRI adoption and implementation may be more successful if they emphasize that procedure times and technical results depend on achieving proficiency. - Highlights: • Sites with few TRIs identified increased radiation exposure as the greatest barrier. • Sites with many TRIs identified the steep learning curve as the greatest barrier. • TFI was rated superior on procedure time and procedure success. • TRI was rated superior on all other criteria

  15. Perceptions of advantages and barriers to radial-access percutaneous coronary intervention in VA cardiac catheterization laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Helfrich, Christian D., E-mail: Christian.Helfrich@va.gov [VA Puget Sound Health Services Research and Development Center of Innovation, US Department of Veterans Affairs, Seattle, WA (United States); Department of Health Services, University of Washington School of Public Health, Seattle, WA (United States); Tsai, Thomas T. [VA Eastern Colorado Health Care System, Denver, CO (United States); Department of Medicine and the Division of Cardiology, University of Colorado School of Medicine, Aurora, CO (United States); Rao, Sunil V. [Cardiac Catheterization Laboratories, Durham VA Medical Center, Durham, NC (United States); Duke Clinical Research Institute, Durham, NC (United States); Lemon, Jaclyn M.; Eugenio, Evercita C. [VA Puget Sound Health Services Research and Development Center of Innovation, US Department of Veterans Affairs, Seattle, WA (United States); Vidovich, Mladen I.; Shroff, Adhir R. [Department of Cardiology, Jesse Brown VA Medical Center, Chicago, IL (United States); Department of Internal Medicine, Section of Interventional Cardiology, University of Illinois at Chicago, Chicago, IL (United States); Speiser, Bernadette S. [Department of Cardiology, Jesse Brown VA Medical Center, Chicago, IL (United States); Bryson, Chris L. [VA Puget Sound Health Services Research and Development Center of Innovation, US Department of Veterans Affairs, Seattle, WA (United States); Division of General Internal Medicine, Department of Medicine, University of Washington, Seattle, WA (United States)

    2014-09-15

    Background/Purpose: Compared with trans-femoral percutaneous coronary intervention (TFI), trans-radial PCI (TRI) has a lower risk of bleeding, access site complications and hospital costs, and is preferred by patients. However, TRI accounts for a minority of PCIs in the US, and there is currently little research that explores why. Methods/Material: We conducted a national survey in February 2013 to assess perceptions of TRI vs. TFI, and barriers to TRI adoption and implementation among interventional cardiologists employed by the US Veterans Health Administration (VHA), and linked these data to site-level TRI annual rates for 2013. Results: We received 78 completed surveys (32% response rate). Respondents at sites that perform few or no TRIs identified increased radiation exposure as the greatest barrier while at sites that perform a high percentage of TRIs respondents identified the steep learning curve as the greatest barrier. Majorities of survey respondents at all sites rated TRI as superior on 5 of 7 criteria, including patient comfort and bleeding complications, but rated TFI as superior on procedure time and procedure success. Conclusions: Even interventional cardiologists at sites that perform few or any TRIs recognized the superiority of TRI for patient comfort and safety, but rated it inferior to TFI on procedure time and technical results. Interventional cardiologists at high-TRI labs rated TRI as equivalent on procedure time and technical results. Efforts to increase TRI adoption and implementation may be more successful if they emphasize that procedure times and technical results depend on achieving proficiency. - Highlights: • Sites with few TRIs identified increased radiation exposure as the greatest barrier. • Sites with many TRIs identified the steep learning curve as the greatest barrier. • TFI was rated superior on procedure time and procedure success. • TRI was rated superior on all other criteria.

  16. Arterial puncture using insulin needle is less painful than with standard needle: a randomized crossover study.

    Science.gov (United States)

    Ibrahim, Irwani; Yau, Ying Wei; Ong, Lizhen; Chan, Yiong Huak; Kuan, Win Sen

    2015-03-01

    Arterial punctures are important procedures performed by emergency physicians in the assessment of ill patients. However, arterial punctures are painful and can create anxiety and needle phobia in patients. The pain score of radial arterial punctures were compared between the insulin needle and the standard 23-gauge hypodermic needle. In a randomized controlled crossover design, healthy volunteers were recruited to undergo bilateral radial arterial punctures. They were assigned to receive either the insulin or the standard needle as the first puncture, using blocked randomization. The primary outcome was the pain score measured on a 100-mm visual analogue scale (VAS) for pain, and secondary outcomes were rate of hemolysis, mean potassium values, and procedural complications immediately and 24 hours postprocedure. Fifty healthy volunteers were included in the study. The mean (±standard deviation) VAS score in punctures with the insulin needle was lower than the standard needle (23 ± 22 mm vs. 39 ± 24 mm; mean difference = -15 mm; 95% confidence interval = -22 mm to -7 mm; p standard needle (31.3% vs. 11.6%, p = 0.035; and 4.6 ±0.7 mmol/L vs. 4.2 ±0.5 mmol/L, p = 0.002). Procedural complications were lower in punctures with the insulin needle both immediately postprocedure (0% vs. 24%; p standard needles. However, due to the higher rate of hemolysis, its use should be limited to conditions that do not require a concurrent potassium value in the same blood sample. © 2015 by the Society for Academic Emergency Medicine.

  17. Radial retinotomy in the macula.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-01-01

    Radial retinotomy is an operative procedure usually performed in the peripheral or equatorial retina. To facilitate retinal attachment, the authors used intraocular scissors to perform radial retinotomy in the macula of two patients during vitrectomy surgery. In the first patient, a retinal detachment complicated by periretinal proliferation and macula hole formation was successfully reoperated with the aid of three radial cuts in the retina at the edges of the macular hole. In the second patient, an intraoperative retinal tear in the macula during diabetic vitrectomy was also successfully repaired with the aid of radial retinotomy. In both patients, retinotomy in the macula was required because epiretinal membranes, which could not be easily delaminated, were hindering retinal reattachment.

  18. Radial head dislocation during proximal radial shaft osteotomy.

    Science.gov (United States)

    Hazel, Antony; Bindra, Randy R

    2014-03-01

    The following case report describes a 48-year-old female patient with a longstanding both-bone forearm malunion, who underwent osteotomies of both the radius and ulna to improve symptoms of pain and lack of rotation at the wrist. The osteotomies were templated preoperatively. During surgery, after performing the planned radial shaft osteotomy, the authors recognized that the radial head was subluxated. The osteotomy was then revised from an opening wedge to a closing wedge with improvement of alignment and rotation. The case report discusses the details of the operation, as well as ways in which to avoid similar shortcomings in the future. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  19. Radial cracks and fracture mechanism of radially oriented ring 2:17 type SmCo magnets

    International Nuclear Information System (INIS)

    Tian Jianjun; Pan Dean; Zhou Hao; Yin Fuzheng; Tao Siwu; Zhang Shengen; Qu Xuanhui

    2009-01-01

    Radially oriented ring 2:17 type SmCo magnets have different microstructure in the radial direction (easy magnetization) and axial direction (hard magnetization). The structure of the cross-section in radial direction is close-packed atomic plane, which shows cellular microstructure. The microstructure of the cross-section in axial direction consists of a mixture of rhombic microstructure and parallel lamella phases. So the magnets have obvious anisotropy of thermal expansion in different directions. The difference of the thermal expansion coefficients reaches the maximum value at 830-860 deg. C, which leads to radial cracks during quenching. The magnets have high brittlement because there are fewer slip systems in crystal structure. The fracture is brittle cleavage fracture.

  20. Comparison of Machine Learning Methods for the Arterial Hypertension Diagnostics

    Directory of Open Access Journals (Sweden)

    Vladimir S. Kublanov

    2017-01-01

    Full Text Available The paper presents results of machine learning approach accuracy applied analysis of cardiac activity. The study evaluates the diagnostics possibilities of the arterial hypertension by means of the short-term heart rate variability signals. Two groups were studied: 30 relatively healthy volunteers and 40 patients suffering from the arterial hypertension of II-III degree. The following machine learning approaches were studied: linear and quadratic discriminant analysis, k-nearest neighbors, support vector machine with radial basis, decision trees, and naive Bayes classifier. Moreover, in the study, different methods of feature extraction are analyzed: statistical, spectral, wavelet, and multifractal. All in all, 53 features were investigated. Investigation results show that discriminant analysis achieves the highest classification accuracy. The suggested approach of noncorrelated feature set search achieved higher results than data set based on the principal components.

  1. Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis

    Directory of Open Access Journals (Sweden)

    Rolanas Dauksevicius

    2013-04-01

    Full Text Available Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner’s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.

  2. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  3. Perceived radial translation during centrifugation

    NARCIS (Netherlands)

    Bos, J.E.; Correia Grácio, B.J.

    2015-01-01

    BACKGROUND: Linear acceleration generally gives rise to translation perception. Centripetal acceleration during centrifugation, however, has never been reported giving rise to a radial, inward translation perception. OBJECTIVE: To study whether centrifugation can induce a radial translation

  4. Triglycerides are a predictive factor for arterial stiffness: a community-based 4.8-year prospective study.

    Science.gov (United States)

    Wang, Xiaona; Ye, Ping; Cao, Ruihua; Yang, Xu; Xiao, Wenkai; Zhang, Yun; Bai, Yongyi; Wu, Hongmei

    2016-05-18

    Epidemiological studies have disclosed an independent effect of triglycerides on coronary heart disease despite achievement of low-density lipoprotein cholesterol goals with statin therapy. Arterial stiffness has been increasingly recognized as a strong predictor of cardiovascular disease and atherosclerotic disease. The association between triglycerides and arterial stiffness is not well characterized. We aimed to determine the relationship between triglycerides and arterial stiffness in a community-based longitudinal sample from Beijing, China. We related levels of plasma TGs to measures of arterial stiffness (carotid-femoral pulse wave velocity [PWV] and carotid-radial PWV) in 1447 subjects (mean age, 61.3 years) from a community-based population in Beijing, China. After a median follow-up interval of 4.8 years, multiple linear regression analysis revealed that TGs were independently associated with carotid-femoral PWV (β = 0.747, P triglyceride levels were significantly associated with decreases in carotid-femoral PWV, indicating that achieving low TG levels may be an additional therapeutic consideration in subjects with atherosclerotic disease.

  5. Arterial Injury and Endothelial Repair: Rapid Recovery of Function after Mechanical Injury in Healthy Volunteers

    Directory of Open Access Journals (Sweden)

    Lindsey Tilling

    2014-01-01

    Full Text Available Objective. Previous studies suggest a protracted course of recovery after mechanical endothelial injury; confounders may include degree of injury and concomitant endothelial dysfunction. We sought to define the time course of endothelial function recovery using flow-mediated dilation (FMD, after ischaemia-reperfusion (IR and mechanical injury in patients and healthy volunteers. The contribution of circulating CD133+/CD34+/VEGFR2+ “endothelial progenitor” (EPC or repair cells to endothelial repair was also examined. Methods. 28 healthy volunteers aged 18–35 years underwent transient forearm ischaemia induced by cuff inflation around the proximal biceps and radial artery mechanical injury induced by inserting a wire through a cannula. A more severe mechanical injury was induced using an arterial sheath and catheter inserted into the radial artery of 18 patients undergoing angiography. Results. IR and mechanical injury produced immediate impairment of FMD (from 6.5 ± 1.2% to 2.9 ± 2.2% and from 7.4 ± 2.3% to 1.5 ± 1.6% for IR and injury, resp., each P<0.001 but recovered within 6 hours and 2 days, respectively. FMD took up to 4 months to recover in patients. Circulating EPC did not change significantly during the injury/recovery period in all subjects. Conclusions. Recovery of endothelial function after IR and mechanical injury is rapid and not associated with a change in circulating EPC.

  6. Self-consistent radial sheath

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1988-12-01

    The boundary layer arising in the radial vicinity of a tokamak limiter is examined, with special reference to the TEXT tokamak. It is shown that sheath structure depends upon the self-consistent effects of ion guiding-center orbit modification, as well as the radial variation of E /times/ B-induced toroidal rotation. Reasonable agreement with experiment is obtained from an idealized model which, however simplified, preserves such self-consistent effects. It is argued that the radial sheath, which occurs whenever confining magnetic field-lines lie in the plasma boundary surface, is an object of some intrinsic interest. It differs from the more familiar axial sheath because magnetized charges respond very differently to parallel and perpendicular electric fields. 11 refs., 1 fig

  7. Non-Euclidean stress-free configuration of arteries accounting for curl of axial strips sectioned from vessels.

    Science.gov (United States)

    Takamizawa, Keiichi; Nakayama, Yasuhide

    2013-11-01

    It is well known that arteries are subject to residual stress. In earlier studies, the residual stress in the arterial ring relieved by a radial cut was considered in stress analysis. However, it has been found that axial strips sectioned from arteries also curled into arcs, showing that the axial residual stresses were relieved from the arterial walls. The combined relief of circumferential and axial residual stresses must be considered to accurately analyze stress and strain distributions under physiological loading conditions. In the present study, a mathematical model of a stress-free configuration of artery was proposed using Riemannian geometry. Stress analysis for arterial walls under unloaded and physiologically loaded conditions was performed using exponential strain energy functions for porcine and human common carotid arteries. In the porcine artery, the circumferential stress distribution under physiological loading became uniform compared with that without axial residual strain, whereas a gradient of axial stress distribution increased through the wall thickness. This behavior showed almost the same pattern that was observed in a recent study in which approximate analysis accounting for circumferential and axial residual strains was performed, whereas the circumferential and axial stresses increased from the inner surface to the outer surface under a physiological condition in the human common carotid artery of a two-layer model based on data of other recent studies. In both analyses, Riemannian geometry was appropriate to define the stress-free configurations of the arterial walls with both circumferential and axial residual strains.

  8. Height and sex is strongly associated with radial augmentation index in Korean patients with never-treated hypertension

    Directory of Open Access Journals (Sweden)

    Ahn KT

    2016-04-01

    Full Text Available Kye Taek Ahn, Kwang-In Park, Mi Joo Kim, Jin Kyung Oh, Ji Hye Han, Hee Jin Kwon, Seon-Ah Jin, Jun-Hyung Kim, Jae-Hyeong Park, Jae-Hwan Lee, Si Wan Choi, In-Whan Seong, Jin-Ok Jeong Department of Internal Medicine, Division of Cardiology, Chungnam National University Hospital, Chungnam National University School of Medicine, Daejeon, Republic of Korea Objectives: Central hemodynamics may better represent the load imposed on the coronary and cerebral arteries and thereby bear a stronger relationship to cardiovascular outcomes. Methods: Patients who had confirmed hypertension as assessed by daytime 24-hour ambulatory blood pressure monitoring (≥135/85 mmHg were enrolled. Central blood pressure and radial augmentation index (AIx corrected for a heart rate of 75 bpm (radial AIx 75 were measured for all patients. We evaluated the association of age, height, and sex with central hemodynamics in patients with never-treated hypertension. Results: A total of 203 patients were enrolled, of whom men numbered 101 (49.7%. The median height of all patients was 162 cm, and mean age was 53.2 years. In the Pearson correlation analysis, regardless of sex difference (R=-0.627 for height, R=0.035 for age, P-value =0.005, a stronger relationship was observed between height and radial AIx 75 than between age and radial AIx 75. In the multiple regression analysis, the sex difference and height were strongly associated with elevated radial AIx 75 in all patients (adjusted R2=0.428, β=6.237, 95% confidence interval [CI] for women 1.480–10.995, P-value =0.011 and β=-0.632, 95% CI for height -0.929 to -0.335, P-value =0.009, respectively. Conclusion: In patients with never-treated hypertension, female sex and shorter height are the important risk factors of elevated radial AIx 75. Keywords: hypertension, augmentation index, height, sex

  9. Numerical simulation of liquid-metal-flows in radial-toroidal-radial bends

    International Nuclear Information System (INIS)

    Molokov, S.; Buehler, L.

    1993-09-01

    Magnetohydrodynamic flows in a U-bend and right-angle bend are considered with reference to the radial-toroidal-radial concept of a self-cooled liquid-metal blanket. The ducts composing bends have rectangular cross-section. The applied magnetic field is aligned with the toroidal duct and perpendicular to the radial ones. At high Hartmann number the flow region is divided into cores and boundary layers of different types. The magnetohydrodynamic equations are reduced to a system of partial differential equations governing wall electric potentials and the core pressure. The system is solved numerically by two different methods. The first method is iterative with iteration between wall potential and the core pressure. The second method is a general one for the solution of the core flow equations in curvilinear coordinates generated by channel geometry and magnetic field orientation. Results obtained are in good agreement. They show, that the 3D-pressure drop of MHD flows in a U-bend is not a critical issue for blanket applications. (orig./HP) [de

  10. Radial wave crystals: radially periodic structures from anisotropic metamaterials for engineering acoustic or electromagnetic waves.

    Science.gov (United States)

    Torrent, Daniel; Sánchez-Dehesa, José

    2009-08-07

    We demonstrate that metamaterials with anisotropic properties can be used to develop a new class of periodic structures that has been named radial wave crystals. They can be sonic or photonic, and wave propagation along the radial directions is obtained through Bloch states like in usual sonic or photonic crystals. The band structure of the proposed structures can be tailored in a large amount to get exciting novel wave phenomena. For example, it is shown that acoustical cavities based on radial sonic crystals can be employed as passive devices for beam forming or dynamically orientated antennas for sound localization.

  11. Revascularização do miocárdio com enxerto livre de artéria radial: experiência inicial

    Directory of Open Access Journals (Sweden)

    Giorgio PIERACCIANI

    1997-07-01

    Full Text Available Foram estudados os resultados precoces do uso do enxerto livre de artéria radial (AR para a revascularização do miocárdio em 20 pacientes operados no período de maio a novembro de 1996. Pertenciam ao sexo masculino 16 (80% com média de idades de 57,1 anos (35 a 69. Foi utilizada a esternotomia mediana com o auxílio da circulação extracorpórea e a cardioplegia sangüínea intermitente em todos os casos. A AR foi retirada do membro superior não dominante e utilizada como parte aorto-coronária em 100% dos casos. Foi realizado um total de 64 enxertos, com média de 3,2 por pacientes (2 a 5. A AR foi anastomosada ao ramo diagonal 9 (45% vezes, ao ramo marginal esquerdo da artéria circunflexa 6 (30%, à coronária direita 4 (20% e ao ramo interventricular anterior 1 (5%. A artéria torácica interna esquerda (ATIE foi utilizada em 100% dos pacientes, a artéria torácica interna direita (ATID em 7 (35%, e a veia safena em 13 (65%. O diltiazen oral foi utilizado no período per-operatório para a prevenção do espasmo arterial. Não houve mortalidade hospitalar ou durante o seguimento de até 10 meses. Foi realizado estudo cineangiocoronáriográfico no período pós-operatório imediato em 17 (85% pacientes, que mostrou fluxo normal na AR em 16 (94,1%. Não houve seqüelas no membro superior do doador. Os resultados observados são semelhantes aos obtidos com a revascularização do miocárdio pelas técnicas usuais no Serviço, sem incremento na morbimortalidade precoce. A normalidade precoce do enxerto de artéria radial mostrou-se comparável ao da artéria torácica interna esquerda, coincidindo com os recentes relatos da técnica.Twenty patients underwent myocardial revascularization with a radial artery (RA between May and November 1996. The mean age was 57.1 years (35 to 69 and 16 patients (80% were male. Midsternotomy, extracorporeal circulation and antegrade blood cardioplegia were always used. A total of 64 grafts, 3.2 per

  12. Ulnar nerve entrapment complicating radial head excision

    Directory of Open Access Journals (Sweden)

    Kevin Parfait Bienvenu Bouhelo-Pam

    Full Text Available Introduction: Several mechanisms are involved in ischemia or mechanical compression of ulnar nerve at the elbow. Presentation of case: We hereby present the case of a road accident victim, who received a radial head excision for an isolated fracture of the radial head and complicated by onset of cubital tunnel syndrome. This outcome could be the consequence of an iatrogenic valgus of the elbow due to excision of the radial head. Hitherto the surgical treatment of choice it is gradually been abandoned due to development of radial head implant arthroplasty. However, this management option is still being performed in some rural centers with low resources. Discussion: The radial head plays an important role in the stability of the elbow and his iatrogenic deformity can be complicated by cubital tunnel syndrome. Conclusion: An ulnar nerve release was performed with favorable outcome. Keywords: Cubital tunnel syndrome, Peripheral nerve palsy, Radial head excision, Elbow valgus

  13. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  14. A Novel Interpretation for Arterial Pulse Pressure Amplification in Health and Disease

    Directory of Open Access Journals (Sweden)

    Manuel R. Alfonso

    2018-01-01

    Full Text Available Arterial pressure waves have been described in one dimension using several approaches, such as lumped (Windkessel or distributed (using Navier-Stokes equations models. An alternative approach consists of modeling blood pressure waves using a Korteweg-de Vries (KdV equation and representing pressure waves as combinations of solitons. This model captures many key features of wave propagation in the systemic network and, in particular, pulse pressure amplification (PPA, which is a mechanical biomarker of cardiovascular risk. The main objective of this work is to compare the propagation dynamics described by a KdV equation in a human-like arterial tree using acquired pressure waves. Furthermore, we analyzed the ability of our model to reproduce induced elastic changes in PPA due to different pathological conditions. To this end, numerical simulations were performed using acquired central pressure signals from different subject groups (young, adults, and hypertensive as input and then comparing the output of the model with measured radial artery pressure waveforms. Pathological conditions were modeled as changes in arterial elasticity (E. Numerical results showed that the model was able to propagate acquired pressure waveforms and to reproduce PPA variations as a consequence of elastic changes. Calculated elasticity for each group was in accordance with the existing literature.

  15. Design of radial reinforcement for prestressed concrete containments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shen, E-mail: swang@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States); Munshi, Javeed A., E-mail: jamunshi@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States)

    2013-02-15

    Highlights: ► A rigorous formulae is proposed to calculate radial stress within prestressed concrete containments. ► The proposed method is validated by finite element analysis in an illustrative practical example. ► A partially prestressed condition is more critical than a fully prestressed condition for radial tension. ► Practical design consideration is provided for detailing of radial reinforcement. -- Abstract: Nuclear containments are critical components for safety of nuclear power plants. Failure can result in catastrophic safety consequences as a result of leakage of radiation. Prestressed concrete containments have been used in large nuclear power plants with significant design internal pressure. These containments are generally reinforced with prestressing tendons in the circumferential (hoop) and meridional (vertical) directions. The curvature effect of the tendons introduces radial tensile stresses in the concrete shell which are generally neglected in the design of such structures. It is assumed that such tensile radial stresses are small as such no radial reinforcement is provided for this purpose. But recent instances of significant delaminations in Crystal River Unit 3 in Florida have elevated the need for reevaluation of the radial tension issue in prestressed containment. Note that currently there are no well accepted industry standards for design and detailing of radial reinforcement. This paper discusses the issue of radial tension in prestressed cylindrical and dome shaped structures and proposes formulae to calculate radial stresses. A practical example is presented to illustrate the use of the proposed method which is then verified by using state of art finite element analysis. This paper also provides some practical design consideration for detailing of radial reinforcement in prestressed containments.

  16. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  17. Nasolabial facial artery and vein as recipient vessels for midface microsurgical reconstruction.

    Science.gov (United States)

    Oh, Suk Joon; Jeon, Man Kyung; Koh, Sung Hoon

    2011-05-01

    Although free flap transfer is commonly performed to reconstruct facial defects, the submandibular facial artery and vein have historically been considered as adequate recipient vessels for microsurgical reconstruction. If the vascular pedicles of the free flap are short, vein grafts are necessary. The purpose of this study was to determine the indications for and effectiveness of using the nasolabial facial vessels for midfacial reconstruction. A retrospective chart review of 6 patients undergoing microsurgical reconstruction for defects of the face revealed 6 free tissue transfers in which the nasolabial facial artery and vein were considered for use as recipient vessels. Flap success rates were evaluated. Six patients (5 men and 1 woman) underwent 6 free flap transfers. Five anterior helix free flaps were used for the reconstruction of defects in the lower third of the nose. Nasal defects were due to trauma in 4 patients and squamous cell carcinoma in 1 patient. In 1 neurofibromatosis type 1 case, a radial forearm flap was used for reconstruction of the left orbital defect. The facial artery and vein in the nasolabial fold were used as the recipient artery and vein in every case. The mean length of follow-up was 5.8 years. All flaps survived. All patients were satisfied with the degree of aesthetic improvement after surgery.Use of the facial artery and vein in the nasolabial fold for facial reconstruction is reliable and safe. The nasolabial facial artery and vein should be considered as primary recipient vessels in microsurgical reconstruction of the midface.

  18. Incremental Value of Increasing Number of Arterial Grafts: The Effect of Diabetes Mellitus.

    Science.gov (United States)

    Schwann, Thomas A; El Hage Sleiman, Abdul Karim M; Yammine, Maroun B; Tranbaugh, Robert F; Engoren, Milo; Bonnell, Mark R; Habib, Robert H

    2018-06-01

    Multiarterial coronary grafting with two arterial grafts leads to improved survival compared with conventional single artery based on left internal thoracic artery to left anterior descending artery and saphenous vein grafts. We investigated whether extending arterial grafting to three or more arterial grafts further improves survival, and whether such a benefit is modified by diabetes mellitus. We analyzed 15-year coronary artery bypass graft surgery mortality data in 11,931 patients (age 64.3 ± 10.5 years; 3,484 women [29.2%]; 4,377 [36.7%] with diabetes mellitus) derived from three US institutions (1994 to 2011). All underwent primary isolated left internal thoracic artery to left anterior descending artery grafting with at least two grafts: one artery (n = 6,782; 56.9%); two arteries (n = 3,678; 30.8%); or three or more arteries (n = 1,471; 12.3%). Long-term survival was estimated by Kaplan-Meier methods. Propensity score matching and comprehensive covariate adjustment (Cox regression) were used to derive long-term risk-adjusted hazard ratio (HR) with 95% confidence interval (CI) for increasing number of arterial grafts in the overall cohort and for diabetes and no-diabetes cohorts. Radial artery (94%) and right internal thoracic artery (6%) were used as additional arterial grafts. Multivariate analysis in all patients showed that diabetes was associated with decreased survival (HR 1.43, 95% CI: 1.34 to 53), whereas increasing number of arterial grafts was associated with decreased mortality (one artery HR 1.0 [reference]; two arteries HR 0.87, 95% CI: 0.80 to 0.95; and three arteries HR 0.83, 95% CI: 0.72 to 0.95). Pairwise comparisons also showed an incremental benefit of additional arterial grafts: two arteries versus one artery, HR 0.89 (95% CI: 0.80 to 0.98); and three arteries versus one artery, HR 0.80 (95% CI: 0.68 to 0.94). A three-artery versus two-artery survival advantage trend was also noted, but was not significant in either the overall study

  19. Modelling and subject-specific validation of the heart-arterial tree system.

    Science.gov (United States)

    Guala, Andrea; Camporeale, Carlo; Tosello, Francesco; Canuto, Claudio; Ridolfi, Luca

    2015-01-01

    A modeling approach integrated with a novel subject-specific characterization is here proposed for the assessment of hemodynamic values of the arterial tree. A 1D model is adopted to characterize large-to-medium arteries, while the left ventricle, aortic valve and distal micro-circulation sectors are described by lumped submodels. A new velocity profile and a new formulation of the non-linear viscoelastic constitutive relation suitable for the {Q, A} modeling are also proposed. The model is firstly verified semi-quantitatively against literature data. A simple but effective procedure for obtaining subject-specific model characterization from non-invasive measurements is then designed. A detailed subject-specific validation against in vivo measurements from a population of six healthy young men is also performed. Several key quantities of heart dynamics-mean ejected flow, ejection fraction, and left-ventricular end-diastolic, end-systolic and stroke volumes-and the pressure waveforms (at the central, radial, brachial, femoral, and posterior tibial sites) are compared with measured data. Mean errors around 5 and 8%, obtained for the heart and arterial quantities, respectively, testify the effectiveness of the model and its subject-specific characterization.

  20. A mechanical argument for the differential performance of coronary artery grafts.

    Science.gov (United States)

    Prim, David A; Zhou, Boran; Hartstone-Rose, Adam; Uline, Mark J; Shazly, Tarek; Eberth, John F

    2016-02-01

    Coronary artery bypass grafting (CABG) acutely disturbs the homeostatic state of the transplanted vessel making retention of graft patency dependent on chronic remodeling processes. The time course and extent to which remodeling restores vessel homeostasis will depend, in part, on the nature and magnitude of the mechanical disturbances induced upon transplantation. In this investigation, biaxial mechanical testing and histology were performed on the porcine left anterior descending artery (LAD) and analogs of common autografts, including the internal thoracic artery (ITA), radial artery (RA), great saphenous vein (GSV) and lateral saphenous vein (LSV). Experimental data were used to quantify the parameters of a structure-based constitutive model enabling prediction of the acute vessel mechanical response pre-transplantation and under coronary loading conditions. A novel metric Ξ was developed to quantify mechanical differences between each graft vessel in situ and the LAD in situ, while a second metric Ω compares the graft vessels in situ to their state under coronary loading. The relative values of these metrics among candidate autograft sources are consistent with vessel-specific variations in CABG clinical success rates with the ITA as the superior and GSV the inferior graft choices based on mechanical performance. This approach can be used to evaluate other candidate tissues for grafting or to aid in the development of synthetic and tissue engineered alternatives. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Free-breathing dynamic liver examination using a radial 3D T1-weighted gradient echo sequence with moderate undersampling for patients with limited breath-holding capacity

    Energy Technology Data Exchange (ETDEWEB)

    Kaltenbach, Benjamin, E-mail: benjamin.kaltenbach@kgu.de [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt am Main (Germany); Roman, Andrei; Polkowski, Christoph; Gruber-Rouh, Tatjana [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt am Main (Germany); Bauer, Ralf W. [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt am Main (Germany); Divison of Radiology and Nuclear Medicine, Kantonsspital, St. Gallen (Switzerland); Hammerstingl, Renate; Vogl, Thomas J.; Zangos, Stephan [Department of Diagnostic and Interventional Radiology, University Hospital Frankfurt am Main (Germany)

    2017-01-15

    Highlights: • Respiratory artifacts are a frequent problem in abdominal MR imaging. • Non-diagnostic examinations could be reduced using free-breathing us-radial-VIBE for dynamic liver examination in challenging patients. • Streak artifacts are characteristic for an undersampled radial acquisition but do not affect diagnostic validity. - Abstract: Purpose: To compare free-breathing radial VIBE with moderate undersampling (us-radial-VIBE) with a standard breathhold T1-weighted volumetric interpolated sequence (3D GRE VIBE) in patients unable to suspend respiration during dynamic liver examination. Material and methods: 23 consecutive patients underwent dynamic liver MR examination using the free-breathing us-radial-VIBE sequence as part of their oncologic follow-up. All patients were eligible for the free-breathing protocol due to severe respiratory artifacts at the planning or precontrast sequences. The us-radial-VIBE acquisitions were compared to the patientś last staging liver MRI including a standard breathhold 3D GRE VIBE. For an objective image evaluation, signal intensity (SI), image noise (IN), signal-to-noise ratio (SNR) and contrast-enhancement ratio (CER) were compared. Representative image quality parameters, including typical artifacts were independently, retrospectively and blindly scored by four readers. Results: Us-radial-VIBE had significant lower SNR (p < 0.0001) and higher IN (p < 0.0001), whereas SI did not differ (p = 0.62). Temporal resolution assessed with CER in the arterial phase showed higher values for us-radial-VIBE (p = 0.028). Subjective image quality parameters received generally slightly higher scores for 3D GRE VIBE. In a smaller subgroup comprising patients with severe respiratory artifacts also at reference breathhold 3D GRE VIBE examination, us-radial-VIBE showed significantly higher image quality scores. Furthermore, there were generally more severe respiratory artifacts in 3D GRE VIBE, whereas streaking was characteristic

  2. Aerobic exercise intensity can be controlled by palpation of the radial artery DOI:10.5007/1980-0037.2010v12n3p186

    Directory of Open Access Journals (Sweden)

    Anselmo José Perez

    2010-01-01

    Full Text Available Heart rate (HR during exercise has been used for the control of aerobic exercise intensity. Palpation is the most popular and accessible method for this purpose. The responses obtained in laboratory tests are used for field application and are suggested to be similar. The objective of this study was to correlate the HR measures obtained by palpation and with a heart rate monitor (HRM in four sessions of aerobic exercise, and to compare the results obtained in the laboratory and in the field. Fifteen healthy young women underwent four sessions of aerobic training of 40 min each at a continuous load, including two sessions on a treadmill and two in the field (50-60% and 80-85% HRmax. During the sessions, HR was recorded minute-by-minute with an HRM (Polar Accurex and measured at 10-minute intervals by pulse palpation. There were significant differences in ∆HR values obtained by palpation and with the HRM between exercise sessions performed on the track and in the laboratory. Strong correlations (r = 0.95 and moderate to strong (r = 0.73 correlations were observed between palpation and HRM in the four sessions. HR during exercise obtained by palpation was underestimated by no more than 5%, but there were no significant differences in mean absolute HR measured by HRM and palpation. For the same exercise intensity, similar results are obtained in the field and laboratory. In addition, HR obtained by palpation of the radial artery immediately after exercise can be used for the control of aerobic exercise intensity.

  3. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  4. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  5. Relationship between glycaemic levels and arterial stiffness in non-diabetic adults.

    Science.gov (United States)

    Cavero-Redondo, Iván; Martínez-Vizcaíno, Vicente; Álvarez-Bueno, Celia; Recio-Rodríguez, José Ignacio; Gómez-Marcos, Manuel Ángel; García-Ortiz, Luis

    2018-01-23

    To examine, in a non-diabetic population, whether the association between arterial stiffness and glycaemic levels depends on the test used as a glycaemic indicator, fasting plasma glucose (FPG) or glycated haemoglobin A1c (HbA1c). A cross-sectional analysis of a 220 non-diabetic subsample from the EVIDENT II study in which FPG, HbA1c and arterial stiffness-related parameters (pulse wave velocity, radial and central augmentation index, and central pulse pressure) were determined. Mean differences in arterial stiffness-related parameters by HbA1c and FPG tertiles were tested using analysis of covariance. All means of arterial stiffness-related parameters increased by HbA1c tertiles, although mean differences were only statistically significant in pulse wave velocity (p ≤.001), even after controlling for potential confounders (HbA1c <5.30% = 6.88 m/s; HbA1c 5.30%-5.59% = 7.06 m/s; and HbA1c ≥5.60% = 8.16 m/s, p =.004). Conversely, mean differences in pulse wave velocity by FPG tertiles did not reach statistically significant differences after controlling for potential confounders (FPG 4.44 mmol/l = 7.18 m/s; FPG 4.44 mmol/l-4.87 mmol/l = 7.26 m/s; and FPG ≥4.88 mmol/l = 7.93 m/s, p =.066). Glucose levels in a non-diabetic population were associated with arterial stiffness but better when levels were determined using HbA1c. Copyright © 2017 Elsevier España, S.L.U. All rights reserved.

  6. Radial velocities of RR Lyrae stars

    International Nuclear Information System (INIS)

    Hawley, S.L.; Barnes, T.G. III

    1985-01-01

    283 spectra of 57 RR Lyrae stars have been obtained using the 2.1-m telescope at McDonald Observatory. Radial velocities were determined using a software cross-correlation technique. New mean radial velocities were determined for 46 of the stars. 11 references

  7. Surgical and Patient Risk Factors for Severe Arterial Line Complications in Adults.

    Science.gov (United States)

    Nuttall, Gregory; Burckhardt, Jennifer; Hadley, Anita; Kane, Sarah; Kor, Daryl; Marienau, Mary Shirk; Schroeder, Darrell R; Handlogten, Kathryn; Wilson, Gregory; Oliver, William C

    2016-03-01

    Prior research has provided inconsistent data regarding the risk factors associated with complications from arterial cannulation. The goal of this study was to clearly define the incidence and risks factors associated with arterial cannulation complications. After obtaining institutional review board approval, all patients requiring arterial line placement with documentation were included in this retrospective study between January 1, 2006, and December 31, 2012. Leveraging two robust data warehouses, the Perioperative DataMart and the Mayo Clinic Life Silences System, the authors cross-matched arterial line cannulation with a documented vascular consult, neurologic consult, infection, or return to surgery within 30 days in order to identify the initial patient population. A total of 62,626 arterial lines were placed in 57,787 patients, and 90.1% of the catheters placed were 20-gauge catheters. The radial artery was cannulated in 94.5% of patients. A total of 21 patients were identified as having experienced vascular complications or nerve injuries, resulting in a complication rate of 3.4 per 10,000 (95% CI, 2.1 to 5.1). Cardiac surgery had the largest number of catheters placed (n = 15,419) with 12 complications (complication rate = 7.8 per 10,000; 95% CI, 4.0 to 13.6). The rate of complications differed significantly (P < 0.001) across the three most common catheter sizes (2.7 per 10,000 [95% CI, 1.5 to 4.4] for 20 gauge, 17.2 per 10,000 [95% CI, 4.7 to 43.9] for 18 gauge, and 9.4 per 10,000 [95% CI, 1.1 to 34.1] for 5 French). In a large retrospective study, the authors document a very low rate of complications with arterial line placement.

  8. Effect of CPAP on arterial stiffness in severely obese patients with obstructive sleep apnoea.

    Science.gov (United States)

    Seetho, Ian W; Asher, Rebecca; Parker, Robert J; Craig, Sonya; Duffy, Nick; Hardy, Kevin J; Wilding, John P H

    2015-12-01

    Obstructive sleep apnoea (OSA) may independently increase cardiovascular risk in obesity. Although there is evidence that arterial stiffness is altered in OSA, knowledge of these effects with continuous positive airway pressure (CPAP) in severe obesity (body mass index (BMI) ≥ 35 kg/m(2)) is limited. This study aimed to explore how arterial stiffness, as measured by the augmentation index (Aix), changed in severely obese patients with OSA who were treated with CPAP and in patients without OSA. Forty-two patients with severe obesity-22 with OSA, 20 without OSA-were recruited at baseline and followed-up after a median of 13.5 months. Pulse wave analysis (PWA) was performed using applanation tonometry at the radial artery to measure augmentation index (Aix), augmentation pressure (AP) and subendocardial viability ratio (SEVR). Cardiovascular parameters and body composition were also measured. There were significant improvements in Aix, AP (both P CPAP compared with subjects without OSA. Epworth scores (P CPAP. Regression showed that CPAP was significantly associated with change in arterial stiffness from baseline. However, patients with OSA on CPAP continued to have increased arterial stiffness (Aix) (P CPAP in severe obesity, CPAP alone is not sufficient to modify PWA measures to levels comparable with non-OSA patients. This supports a need for a multifaceted approach when managing cardiovascular risk in patients with severe obesity and obstructive sleep apnoea receiving CPAP therapy.

  9. Radial MR images of the knee

    International Nuclear Information System (INIS)

    Hewes, R.C.; Miller, T.R.

    1988-01-01

    To profile optimally each portion of the meniscus, the authors use the multiangle, multisection feature of a General Electric SIGNA 1.5-T imager to produce radial images centered on each meniscus. A total of 12-15 sections are imaged at 10 0 -15 0 intervals of each meniscus, yielding perpendicular images of the entire meniscus, comparable with the arthrographic tangential views. The authors review their technique and demonstrate correlation cases between the radial gradient recalled acquisition in a steady state sequences, sagittal and coronal MR images, and arthrograms. Radial images should be a routine part of knee MR imaging

  10. 21 CFR 866.4800 - Radial immunodiffusion plate.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4800 Radial immunodiffusion plate. (a) Identification. A radial immunodiffusion plate for clinical use...

  11. Stirling Engine With Radial Flow Heat Exchangers

    Science.gov (United States)

    Vitale, N.; Yarr, George

    1993-01-01

    Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

  12. Hemodynamic and arterial stiffness differences between African-Americans and Caucasians after maximal exercise.

    Science.gov (United States)

    Yan, Huimin; Ranadive, Sushant M; Heffernan, Kevin S; Lane, Abbi D; Kappus, Rebecca M; Cook, Marc D; Wu, Pei-Tzu; Sun, Peng; Harvey, Idethia S; Woods, Jeffrey A; Wilund, Kenneth R; Fernhall, Bo

    2014-01-01

    African-American (AA) men have higher arterial stiffness and augmentation index (AIx) than Caucasian-American (CA) men. Women have greater age-associated increases in arterial stiffness and AIx than men. This study examined racial and sex differences in arterial stiffness and central hemodynamics at rest and after an acute bout of maximal exercise in young healthy individuals. One hundred young, healthy individuals (28 AA men, 24 AA women, 25 CA men, and 23 CA women) underwent measurements of aortic blood pressure (BP) and arterial stiffness at rest and 15 and 30 min after an acute bout of graded maximal aerobic exercise. Aortic BP and AIx were derived from radial artery applanation tonometry. Aortic stiffness (carotid-femoral) was measured via pulse wave velocity. Aortic stiffness was increased in AA subjects but not in CA subjects (P < 0.05) after an acute bout of maximal cycling exercise, after controlling for body mass index. Aortic BP decreased after exercise in CA subjects but not in AA subjects (P < 0.05). Women exhibited greater reductions in AIx after maximal aerobic exercise compared with men (P < 0.05). In conclusion, race and sex impact vascular and central hemodynamic responses to exercise. Young AA and CA subjects exhibited differential responses in central stiffness and central BP after acute maximal exercise. Premenopausal women had greater augmented pressure at rest and after maximal aerobic exercise than men. Future research is needed to examine the potential mechanisms.

  13. Working at Night in Hospital Environment is a Risk Factor for Arterial Stiffness

    Directory of Open Access Journals (Sweden)

    Sinem Özbay

    2012-09-01

    Full Text Available Aim: Arterial stiffness is an independent risk factor for cardiovascular disease. In previous studies, emotional stress has been reported to be a risk factor for cardiovascular disease. In this study, we aimed to investigate the effects of anxiety, stress and fatigue associated with working at night in hospital environment on arterial stiffness in physicians. Methods: The study was carried out with 30 physicians employed in Medical Faculty of Uludağ University between October 2011 and March 2012. Measurements were made using Pulse Wave Sensor HDI system (Hypertension Diagnostics Inc, Eagan, MN(Set No: CR000344 by radial artery pulse wave at the onset and end of night shift. Results: The mean age of night doctors included in the study was 26 years (range: 22-38 and the female/male ratio was 2/1. It was determined that mean values of arterial stiffness were significantly higher after night shift (1330±360 dyne/sn/cm-5 compared to mean values before night shift (1093±250 dyn/s/cm-5 (p=0.01. In the evaluation of other parameters before and after night shift, no statistically significant difference was detected (p>0.05. Conclusion: The increasing arterial stiffness in hospital employees after night shift could be attributed to the effects of stress and fatigue experienced during night shift. (The Me di cal Bul le tin of Ha se ki 2012; 50: 93-5

  14. The effect of acute maximal exercise on postexercise hemodynamics and central arterial stiffness in obese and normal-weight individuals.

    Science.gov (United States)

    Bunsawat, Kanokwan; Ranadive, Sushant M; Lane-Cordova, Abbi D; Yan, Huimin; Kappus, Rebecca M; Fernhall, Bo; Baynard, Tracy

    2017-04-01

    Central arterial stiffness is associated with incident hypertension and negative cardiovascular outcomes. Obese individuals have higher central blood pressure (BP) and central arterial stiffness than their normal-weight counterparts, but it is unclear whether obesity also affects hemodynamics and central arterial stiffness after maximal exercise. We evaluated central hemodynamics and arterial stiffness during recovery from acute maximal aerobic exercise in obese and normal-weight individuals. Forty-six normal-weight and twenty-one obese individuals underwent measurements of central BP and central arterial stiffness at rest and 15 and 30 min following acute maximal exercise. Central BP and normalized augmentation index (AIx@75) were derived from radial artery applanation tonometry, and central arterial stiffness was obtained via carotid-femoral pulse wave velocity (cPWV) and corrected for central mean arterial pressure (cPWV/cMAP). Central arterial stiffness increased in obese individuals but decreased in normal-weight individuals following acute maximal exercise, after adjusting for fitness. Obese individuals also exhibited an overall higher central BP ( P  <   0.05), with no exercise effect. The increase in heart rate was greater in obese versus normal-weight individuals following exercise ( P  <   0.05), but there was no group differences or exercise effect for AIx@75 In conclusion, obese (but not normal-weight) individuals increased central arterial stiffness following acute maximal exercise. An assessment of arterial stiffness response to acute exercise may serve as a useful detection tool for subclinical vascular dysfunction. © 2017 The Authors. Physiological Reports published by Wiley Periodicals, Inc. on behalf of The Physiological Society and the American Physiological Society.

  15. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  16. [Radial Approach for Percutaneous Coronary Interventions in Patients With Ischemic Heart Disease: Advantages and Disadvantages, Complications Rate in Comparison With Femoral Approach].

    Science.gov (United States)

    Fettser, D V; Batyraliev, T A; Pershukov, I V; Vanyukov, A E; Sidorenko, B A

    2017-05-01

    During recent 10-15 years, percutaneous coronary interventions (PCI) have reached a new level of efficacy and safety. Rate of serious coronary complications has decreased. That to a greater degree exposes the problem of peripheral complications at the site of arterial approach. At the same time portion of patients older than 75 years in the total pool of PCI constantly increases. Number of patients with pronounced obesity also grows each year. Radial approach for PCI allows to substantially decrease rate of peripheral complications at the account of lowered rate of bleedings, and to shorten duration of hospitalization. In this literature review we present results of a number of relevant clinical studies including those which contained groups of elderly patients and of patients with obesity. We also have summarized main advantages and disadvantages of radial approach as compared with femoral approach for coronary angiography and PCI.

  17. Anatomía arterial de los colgajos musculares de extensor carpi radialis longus y extensor carpi radialis brevis para su uso en transferencia muscular funcional libre Arterial anatomy of the extensor carpi radialis longus and extensor carpi radialis brevis muscle flaps related to its use in free functioning muscle transfer

    Directory of Open Access Journals (Sweden)

    A. Rodríguez Lorenzo

    2008-09-01

    Full Text Available El objetivo de este trabajo es documentar el aporte arterial y el patrón vascular intramuscular de los músculos Extensor Carpi Radialis Longus (ECRL y Extensor Carpi Radialis Brevis (ECRB para analizar su utilización como colgajos libres en transferencia muscular funcional para reanimación facial. Realizamos un estudio anatómico en 29 brazos humanos en fresco. Las técnicas de inyección utilizadas fueron la modificada de oxido de plomo y gelatina en 11 cadáveres y la de inyección pulsátil de látex color en 18. Disecamos los músculos ECRL y ECRB y sus pedículos, los fotodocumentamos y radiografiamos valorando los resultados en función del patrón vascular intramuscular, relaciones anatómicas, calibres y longitud de pedículos. Encontramos dos patrones vasculares diferentes en las 29 disecciones siguiendo la clasificación de Mathes y Nahai de la anatomía vascular de los músculos (en función del número de pedículos vasculares y su dominancia: Tipo I( 37,9% ECRL y 20,7% ECRB y Tipo II(62,1% del ECRL y 79,3% del ECRB. El pedículo principal del ECRL (de diámetro medio 1,73 mm y longitud de pedículo media de 32,32 mm es en el 100% de los casos rama de la arteria recurrente radial y el pedículo principal del ECRB (de diámetro medio 1,11 mm y longitud de pedículo media de 27,77 mm es rama de la arteria radial en el 68,9% de los casos y de la arteria recurrente radial en el 31,1% de los casos. Concluimos que El ECRL y ECRB presentan dos tipos de patrones vasculares: tipo I y tipo II, siendo más frecuente en nuestro trabajo el tipo II, que hacen que ambos puedan ser transferidos como colgajos libres por su pedículo principal. Ambos músculos presentan un tamaño, contorno, contenido fascial importante para el anclaje de suturas y una longitud de pedículo y calibre vascular adecuados para su transferencia microvascular libre en reanimación facial. De los dos, el más realizable como colgajo libre es el ECRB ya que la relaci

  18. Radial pattern of nuclear decay processes

    International Nuclear Information System (INIS)

    Iskra, W.; Mueller, M.; Rotter, I.; Technische Univ. Dresden

    1994-05-01

    At high level density of nuclear states, a separation of different time scales is observed (trapping effect). We calculate the radial profile of partial widths in the framework of the continuum shell model for some 1 - resonances with 2p-2h nuclear structure in 16 O as a function of the coupling strength to the continuum. A correlation between the lifetime of a nuclear state and the radial profile of the corresponding decay process is observed. We conclude from our numerical results that the trapping effect creates structures in space and time characterized by a small radial extension and a short lifetime. (orig.)

  19. Dual-modality arterial pulse monitoring system for continuous blood pressure measurement.

    Science.gov (United States)

    Wen-Xuan Dai; Yuan-Ting Zhang; Jing Liu; Xiao-Rong Ding; Ni Zhao

    2016-08-01

    Accurate and ambulatory measurement of blood pressure (BP) is essential for efficient diagnosis, management and prevention of cardiovascular diseases (CVDs). However, traditional cuff-based BP measurement methods provide only intermittent BP readings and can cause discomfort with the occlusive cuff. Although pulse transit time (PTT) method is promising for cuffless and continuous BP measurement, its pervasive use is restricted by its limited accuracy and requirement of placing sensors on multiple body sites. To tackle these issues, we propose a novel dual-modality arterial pulse monitoring system for continuous blood pressure measurement, which simultaneously records the pressure and photoplethysmography (PPG) signals of radial artery. The obtained signals can be used to generate a pressure-volume curve, from which the elasticity index (EI) and viscosity index (VI) can be extracted. Experiments were carried out among 7 healthy subjects with their PPG, ECG, arterial pressure wave and reference BP collected to examine the effectiveness of the proposed indexes. The results of this study demonstrate that a linear regression model combining EI and VI has significantly higher BP tracking correlation coefficient as compared to the PTT method. This suggests that the proposed system and method can potentially be used for convenient and continuous blood pressure estimation with higher accuracy.

  20. Channeling of protons through radial deformed carbon nanotubes

    Energy Technology Data Exchange (ETDEWEB)

    Borka Jovanović, V., E-mail: vborka@vinca.rs [Atomic Physics Laboratory (040), Vinča Institute of Nuclear Sciences, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Borka, D. [Atomic Physics Laboratory (040), Vinča Institute of Nuclear Sciences, University of Belgrade, P.O. Box 522, 11001 Belgrade (Serbia); Galijaš, S.M.D. [Faculty of Physics, University of Belgrade, P.O. Box 368, 11001 Belgrade (Serbia)

    2017-05-18

    Highlights: • For the first time we presented theoretically obtained distributions of channeled protons with radially deformed SWNT. • Our findings indicate that influence of the radial deformation is very strong and it should not be omitted in simulations. • We show that the spatial and angular distributions depend strongly of level of radial deformation of nanotube. • Our obtained results can be compared with measured distributions to reveal the presence of various types of defects in SWNT. - Abstract: In this paper we have presented a theoretical investigation of the channeling of 1 GeV protons with the radial deformed (10, 0) single-wall carbon nanotubes (SWNTs). We have calculated channeling potential within the deformed nanotubes. For the first time we presented theoretically obtained spatial and angular distributions of channeled protons with radially deformed SWNT. We used a Monte Carlo (MC) simulation technique. We show that the spatial and angular distributions depend strongly of level of radial deformation of nanotube. These results may be useful for nanotube characterization and production and guiding of nanosized ion beams.

  1. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  2. Elevated pulmonary arterial and systemic plasma aldosterone levels associate with impaired cardiac reserve capacity during exercise in left ventricular systolic heart failure patients: A pilot study.

    Science.gov (United States)

    Maron, Bradley A; Stephens, Thomas E; Farrell, Laurie A; Oldham, William M; Loscalzo, Joseph; Leopold, Jane A; Lewis, Gregory D

    2016-03-01

    Elevated levels of aldosterone are a modifiable contributor to clinical worsening in heart failure with reduced ejection fraction (HFrEF). Endothelin-1 (ET-1), which is increased in HFrEF, induces pulmonary endothelial aldosterone synthesis in vitro. However, whether transpulmonary aldosterone release occurs in humans or aldosterone relates to functional capacity in HFrEF is not known. Therefore, we aimed to characterize ET-1 and transpulmonary aldosterone levels in HFrEF and determine if aldosterone levels relate to peak volume of oxygen uptake (pVO2). Data from 42 consecutive HFrEF patients and 18 controls referred for invasive cardiopulmonary exercise testing were analyzed retrospectively. Radial ET-1 levels (median [interquartile range]) were higher in HFrEF patients compared with controls (17.5 [11.5-31.4] vs 11.5 [4.4-19.0] pg/ml, p = 0.04). A significant ET-1 transpulmonary gradient (pulmonary arterial [PA] - radial arterial levels) was present in HFrEF (p reserve capacity in HFrEF. Published by Elsevier Inc.

  3. One-year results of total arterial revascularization vs. conventional coronary surgery: CARRPO trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Wetterslev, Jørn; Lund, Jens T

    2009-01-01

    +/- 18% in the conventional group (P = 0.52). In 72% of TAR patients and 67% of the conventional group, all grafts were patent (P = 0.45). Multiple imputation of missing angiographic data did not influence on results. Within 1 year, 37 (23%) TAR patients and 43 (25%) conventional group patients suffered...... cardiac events (HR 1.09, 95% CI 0.70-1.69, P = 0.70). One patient (0.6%) in the TAR group and two (1.2%) in the conventional group died (P = 1.00). CONCLUSION: Within 1 year post-operatively, TAR seems at least as safe and effective as CR. Prolonged follow-up will reveal whether this is sustained......AIMS: To investigate clinical and angiographic outcomes after coronary surgery using total arterial revascularization (TAR). METHODS AND RESULTS: We randomized 331 patients with multivessel or isolated left main disease to TAR [internal thoracic (ITA) and radial arteries] vs. conventional...

  4. Radial electric fields for improved tokamak performance

    International Nuclear Information System (INIS)

    Downum, W.B.

    1981-01-01

    The influence of externally-imposed radial electric fields on the fusion energy output, energy multiplication, and alpha-particle ash build-up in a TFTR-sized, fusing tokamak plasma is explored. In an idealized tokamak plasma, an externally-imposed radial electric field leads to plasma rotation, but no charge current flows across the magnetic fields. However, a realistically-low neutral density profile generates a non-zero cross-field conductivity and the species dependence of this conductivity allows the electric field to selectively alter radial particle transport

  5. Interactions between Radial Electric Field, Transport and Structure in Helical Plasmas

    International Nuclear Information System (INIS)

    Ida, Katsumi and others

    2006-01-01

    Control of the radial electric field is considered to be important in helical plasmas, because the radial electric field and its shear are expected to reduce neoclassical and anomalous transport, respectively. Particle and heat transport, that determines the radial structure of density and electron profiles, sensitive to the structure of radial electric field. On the other hand, the radial electric field itself is determined by the plasma parameters. In general, the sign of the radial electric field is determined by the plasma collisionality, while the magnitude of the radial electric field is determined by the temperature and/or density gradients. Therefore the structure of radial electric field and temperature and density are strongly coupled through the particle and heat transport and formation mechanism of radial electric field. Interactions between radial electric field, transport and structure in helical plasmas is discussed based on the experiments on Large Helical Device

  6. Fuel radial design using Path Relinking; Diseno radial de combustible usando Path Relinking

    Energy Technology Data Exchange (ETDEWEB)

    Campos S, Y. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The present work shows the obtained results when implementing the combinatory optimization technique well-known as Path Re linking (Re-linkage of Trajectories), to the problem of the radial design of nuclear fuel assemblies, for boiling water reactors (BWR Boiling Water Reactor by its initials in English), this type of reactors is those that are used in the Laguna Verde Nucleo electric Central, Veracruz. As in any other electric power generation plant of that make use of some fuel to produce heat and that it needs each certain time (from 12 to 14 months) to make a supply of the same one, because this it wears away or it burns, in the nucleolectric plants to this activity is denominated fuel reload. In this reload different activities intervene, among those which its highlight the radial and axial designs of fuel assemblies, the patterns of control rods and the multi cycles study, each one of these stages with their own complexity. This work was limited to study in independent form the radial design, without considering the other activities. These phases are basic for the fuel reload design and of reactor operation strategies. (Author)

  7. Clinical and Radiographic Outcomes of Unipolar and Bipolar Radial Head Prosthesis in Patients with Radial Head Fracture: A Systemic Review and Meta-Analysis.

    Science.gov (United States)

    Chen, Hongwei; Wang, Ziyang; Shang, Yongjun

    2018-06-01

    To compare clinical outcomes of unipolar and bipolar radial head prosthesis in the treatment of patients with radial head fracture. Medline, Cochrane, EMBASE, Google Scholar databases were searched until April 18, 2016 using the following search terms: radial head fracture, elbow fracture, radial head arthroplasty, implants, prosthesis, unipolar, bipolar, cemented, and press-fit. Randomized controlled trials, retrospective, and cohort studies were included. The Mayo elbow performance score (MEPS), disabilities of the arm, shoulder, and hand (DASH) score, radiologic assessment, ROM, and grip strength following elbow replacement were similar between prosthetic devices. The pooled mean excellent/good ranking of MEPS was 0.78 for unipolar and 0.73 for bipolar radial head arthroplasty, and the pooled mean MEPS was 86.9 and 79.9, respectively. DASH scores for unipolar and bipolar prosthesis were 19.0 and 16.3, respectively. Range of motion outcomes were similar between groups, with both groups have comparable risk of flexion arc, flexion, extension deficit, rotation arc, pronation, and supination (p values bipolar prosthesis). However, bipolar radial head prosthesis was associated with an increased chance of heterotopic ossification and lucency (p values ≤0.049) while unipolar prosthesis was not (p values ≥0.088). Both groups had risk for development of capitellar osteopenia or erosion/wear (p values ≤0.039). Unipolar and bipolar radial head prostheses were similar with respect to clinical outcomes. Additional comparative studies are necessary to further compare different radial head prostheses used to treat radial head fracture.

  8. Vitreous veils and radial lattice in Marshall syndrome.

    Science.gov (United States)

    Brubaker, Jacob W; Mohney, Brian G; Pulido, Jose S; Babovic-Vuksanovic, Dusica

    2008-12-01

    To report the findings of membranous vitreous veils and radial lattice in a child with Marshall syndrome. Observational case report. Retrospective review of medical records and fundus photograph of a 6-year-old boy with Marshall syndrome. Vitreoretinal findings were significant for bilateral membranous vitreous veils and radial lattice degeneration. This case demonstrates the occurrence of vitreous veils and radial lattice degeneration in patients with Marshall syndrome.

  9. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  10. Long-Term Follow-up of Modular Metallic Radial Head Replacement: Commentary on an article by Jonathan P. Marsh, MD, FRCSC, et al.: "Radial Head Fractures Treated with Modular Metallic Radial Head Replacement: Outcomes at a Mean Follow-up of Eight Years".

    OpenAIRE

    Mansat, Pierre

    2016-01-01

    Radial head arthroplasty is used to stabilize the joint after a complex acute radial head fracture that is not amenable for fixation or to treat sequelae of radial head fractures. Most of the currently used radial head prostheses are metallic monoblock implants that are not consistently adaptable and raise technical challenges since their implantation requires lateral elbow subluxation. Metallic modular radial head arthroplasty implants available in various head and stem sizes have been devel...

  11. Radial head fracture associated with posterior interosseous nerve injury

    Directory of Open Access Journals (Sweden)

    Bernardo Barcellos Terra

    Full Text Available ABSTRACT Fractures of the radial head and radial neck correspond to 1.7-5.4% of all fractures and approximately 30% may present associated injuries. In the literature, there are few reports of radial head fracture with posterior interosseous nerve injury. This study aimed to report a case of radial head fracture associated with posterior interosseous nerve injury. CASE REPORT: A male patient, aged 42 years, sought medical care after falling from a skateboard. The patient related pain and limitation of movement in the right elbow and difficulty to extend the fingers of the right hand. During physical examination, thumb and fingers extension deficit was observed. The wrist extension showed a slight radial deviation. After imaging, it became evident that the patient had a fracture of the radial head that was classified as grade III in the Mason classification. The patient underwent fracture fixation; at the first postoperative day, thumb and fingers extension was observed. Although rare, posterior interosseous nerve branch injury may be associated with radial head fractures. In the present case, the authors believe that neuropraxia occurred as a result of the fracture hematoma and edema.

  12. Radial Field Piezoelectric Diaphragms

    Science.gov (United States)

    Bryant, R. G.; Effinger, R. T., IV; Copeland, B. M., Jr.

    2002-01-01

    A series of active piezoelectric diaphragms were fabricated and patterned with several geometrically defined Inter-Circulating Electrodes "ICE" and Interdigitated Ring Electrodes "ICE". When a voltage potential is applied to the electrodes, the result is a radially distributed electric field that mechanically strains the piezoceramic along the Z-axis (perpendicular to the applied electric field). Unlike other piezoelectric bender actuators, these Radial Field Diaphragms (RFDs) strain concentrically yet afford high displacements (several times that of the equivalent Unimorph) while maintaining a constant circumference. One of the more intriguing aspects is that the radial strain field reverses itself along the radius of the RFD while the tangential strain remains relatively constant. The result is a Z-deflection that has a conical profile. This paper covers the fabrication and characterization of the 5 cm. (2 in.) diaphragms as a function of poling field strength, ceramic thickness, electrode type and line spacing, as well as the surface topography, the resulting strain field and displacement as a function of applied voltage at low frequencies. The unique features of these RFDs include the ability to be clamped about their perimeter with little or no change in displacement, the environmentally insulated packaging, and a highly repeatable fabrication process that uses commodity materials.

  13. Radial transport with perturbed magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hazeltine, R. D. [Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States)

    2015-05-15

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order.

  14. Radial transport with perturbed magnetic field

    International Nuclear Information System (INIS)

    Hazeltine, R. D.

    2015-01-01

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order

  15. Radial optic neurotomy for ischaemic central vein occlusion

    Science.gov (United States)

    Martínez-Jardón, C S; Meza-de Regil, A; Dalma-Weiszhausz, J; Leizaola-Fernández, C; Morales-Cantón, V; Guerrero-Naranjo, J L; Quiroz-Mercado, H

    2005-01-01

    Background/aims: Ischaemic central retinal vein occlusion (CRVO) accounts for 20–50% of all CRVO. No treatment has been proved to be effective. The efficacy of radial optic neurotomy (RON) was evaluated in eyes with ischaemic CRVO. Methods: 10 patients with ischaemic CRVO underwent RON. After pars plana vitrectomy, a microvitreoretinal blade was used to incise the scleral ring, cribriform plate, and adjacent sclera at the nasal edge of the optic disc. Best corrected visual acuity (BCVA), intraocular pressure (IOP), fluorescein angiography (FA), multifocal electroretinography (mfERG), and optical coherence tomography (OCT) were measured preoperatively and at 1, 3, and 6 months postoperatively. Results: No visual improvement was noted in the eyes that underwent RON. FA and mfERG showed no increase in retinal perfusion or retinal function postoperatively. Mean macular central thickness changed from 841 (SD 170) μm preoperatively to 162 (SD 34) μm at the sixth postoperative month. One patient had retinal central artery perforation intraoperatively. One patient developed neovascular glaucoma. Conclusion: RON in ischaemic CRVO did not improve visual function (by mfERG) or visual acuity although macular thickness did improve. This technique may be associated with potential risks. Randomised studies are needed to corroborate these results. PMID:15834084

  16. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  17. The superficial ulnar artery: development and clinical significance Artéria ulnar superficial: desenvolvimento e relevância clínica

    Directory of Open Access Journals (Sweden)

    Srinivasulu Reddy

    2007-09-01

    Full Text Available The principal arteries of the upper limb show a wide range of variation that is of considerable interest to orthopedic surgeons, plastic surgeons, radiologists and anatomists. We present here a case of superficial ulnar artery found during the routine dissection of right upper limb of a 50-year-old male cadaver. The superficial ulnar artery originated from the brachial artery, crossed the median nerve anteriorly and ran lateral to this nerve and the brachial artery. The superficial ulnar artery in the arm gave rise to a narrow muscular branch to the biceps brachii. At the elbow level the artery ran superficial to the bicipital aponeurosis where it was crossed by the median cubital vein. It then ran downward and medially superficial to the forearm flexor muscles, and then downward to enter the hand. At the palm, it formed the superficial and deep palmar arches together with the branches of the radial artery. The presence of a superficial ulnar artery is clinically important when raising forearm flaps in reconstructive surgery. The embryology and clinical significance of the variation are discussed.As principais artérias do membro superior apresentam uma ampla variação, que é relativamente importante a cirurgiões ortopédicos e plásticos, radiologistas e anatomistas.Apresentamosumcaso de artéria ulnar superficial encontrada durante dissecção de rotina de membro superior direito de um cadáver masculino de 50 anos de idade.Aartéria ulnar superficial originava-se da artéria braquial, cruzava o nervo mediano anteriormente e percorria lateralmente esse nervo e a artéria braquial. A artéria ulnar superficial no braço deu origem a um ramo muscular estreito do músculo bíceps braquial. Ao nível do cotovelo, a artéria percorria superficialmente a aponeurose bicipital, onde era cruzada pela veia cubital mediana. Percorria, então, em sentido descendente e medialmente superficial aos músculos flexores do antebraço, e então descendia para

  18. Concepts of radial and angular kinetic energies

    DEFF Research Database (Denmark)

    Dahl, Jens Peder; Schleich, W.P.

    2002-01-01

    We consider a general central-field system in D dimensions and show that the division of the kinetic energy into radial and angular parts proceeds differently in the wave-function picture and the Weyl-Wigner phase-space picture, Thus, the radial and angular kinetic energies are different quantities...

  19. Mid-term results of off-pump coronary artery bypass grafting assessed by multi-slice computed tomography

    International Nuclear Information System (INIS)

    Yoshida, Seijiro; Nitta, Yoshio; Oda, Katsuhiko

    2004-01-01

    Off-pump coronary artery bypass (OPCAB) has recently increased in popularity, but the long-term results are still unknown. We evaluated the mid-term results of OPCAB surgery using multi-slice computed tomography (MSCT), which is a non-invasive postoperative evaluation method. Thirty-one consecutive patients who underwent OPCAB surgery at least 2 years prior to the study were selected. The age was 50 to 79 years (66.9±6.5) and the ratio of men to women was 26:5. Coronary angiography was performed in all patients at 2 weeks postoperatively. The follow-up was complete, and mean follow-up was 30.9 months. There were no hospital deaths and 1 non-cardiac late death. The graft patency rate in coronary angiography was left internal thoracic artery (LITA) 30/30 (100%), right internal thoracic artery (RITA) 2/2 (100%), radial artery (RA) 14/15 (93%), saphenous vein graft (SVG) 15/17 (88%). No graft became occluded on MSCT study and all patients have been angina-free during the follow-up period. We suggest that OPCAB is feasible in most patients with good patency and low mortality. MSCT is an effective follow up method for the morphological findings and noninvasive quantitative evaluation of the bypass grafts. (author)

  20. Radial gradient and radial deviation radiomic features from pre-surgical CT scans are associated with survival among lung adenocarcinoma patients.

    Science.gov (United States)

    Tunali, Ilke; Stringfield, Olya; Guvenis, Albert; Wang, Hua; Liu, Ying; Balagurunathan, Yoganand; Lambin, Philippe; Gillies, Robert J; Schabath, Matthew B

    2017-11-10

    The goal of this study was to extract features from radial deviation and radial gradient maps which were derived from thoracic CT scans of patients diagnosed with lung adenocarcinoma and assess whether these features are associated with overall survival. We used two independent cohorts from different institutions for training (n= 61) and test (n= 47) and focused our analyses on features that were non-redundant and highly reproducible. To reduce the number of features and covariates into a single parsimonious model, a backward elimination approach was applied. Out of 48 features that were extracted, 31 were eliminated because they were not reproducible or were redundant. We considered 17 features for statistical analysis and identified a final model containing the two most highly informative features that were associated with lung cancer survival. One of the two features, radial deviation outside-border separation standard deviation, was replicated in a test cohort exhibiting a statistically significant association with lung cancer survival (multivariable hazard ratio = 0.40; 95% confidence interval 0.17-0.97). Additionally, we explored the biological underpinnings of these features and found radial gradient and radial deviation image features were significantly associated with semantic radiological features.

  1. Illumination Profile & Dispersion Variation Effects on Radial Velocity Measurements

    Science.gov (United States)

    Grieves, Nolan; Ge, Jian; Thomas, Neil B.; Ma, Bo; Li, Rui; SDSS-III

    2015-01-01

    The Multi-object APO Radial-Velocity Exoplanet Large-Area Survey (MARVELS) measures radial velocities using a fiber-fed dispersed fixed-delay interferometer (DFDI) with a moderate dispersion spectrograph. This setup allows a unique insight into the 2D illumination profile from the fiber on to the dispersion grating. Illumination profile investigations show large changes in the profile over time and fiber location. These profile changes are correlated with dispersion changes and long-term radial velocity offsets, a major problem within the MARVELS radial velocity data. Characterizing illumination profiles creates a method to both detect and correct radial velocity offsets, allowing for better planet detection. Here we report our early results from this study including improvement of radial velocity data points from detected giant planet candidates. We also report an illumination profile experiment conducted at the Kitt Peak National Observatory using the EXPERT instrument, which has a DFDI mode similar to MARVELS. Using profile controlling octagonal-shaped fibers, long term offsets over a 3 month time period were reduced from ~50 m/s to within the photon limit of ~4 m/s.

  2. Radial transfer effects for poloidal rotation

    Science.gov (United States)

    Hallatschek, Klaus

    2010-11-01

    Radial transfer of energy or momentum is the principal agent responsible for radial structures of Geodesic Acoustic Modes (GAMs) or stationary Zonal Flows (ZF) generated by the turbulence. For the GAM, following a physical approach, it is possible to find useful expressions for the individual components of the Poynting flux or radial group velocity allowing predictions where a mathematical full analysis is unfeasible. Striking differences between up-down symmetric flux surfaces and asymmetric ones have been found. For divertor geometries, e.g., the direction of the propagation depends on the sign of the ion grad-B drift with respect to the X-point, reminiscent of a sensitive determinant of the H-mode threshold. In nonlocal turbulence computations it becomes obvious that the linear energy transfer terms can be completely overwhelmed by the action of the turbulence. In contrast, stationary ZFs are governed by the turbulent radial transfer of momentum. For sufficiently large systems, the Reynolds stress becomes a deterministic functional of the flows, which can be empirically determined from the stress response in computational turbulence studies. The functional allows predictions even on flow/turbulence states not readily obtainable from small amplitude noise, such as certain transport bifurcations or meta-stable states.

  3. Left Ventricular Function in Patients with Pulmonary Arterial Hypertension: The Role of Two-Dimensional Speckle Tracking Strain.

    Science.gov (United States)

    de Amorim Corrêa, Ricardo; de Oliveira, Fernanda Brito; Barbosa, Marcia M; Barbosa, Jose Augusto A; Carvalho, Taís Soares; Barreto, Michele Campos; Campos, Frederico Thadeu A F; Nunes, Maria Carmo Pereira

    2016-09-01

    Pulmonary arterial hypertension (PAH) is characterized by elevated mean pulmonary arterial pressure with abnormal right ventricular (RV) pressure overload that may alter left ventricular (LV) function. The aim of this study was to assess the impact of RV pressure overload on LV function in PAH patients using two-dimensional (2D) speckle tracking strain. The study enrolled 37 group 1 PAH patients and 38 age- and gender-matched healthy controls. LV longitudinal and radial 2D strains were measured with and without including the ventricular septum. Six-minute walk test (6MWT) and brain natriuretic peptide (BNP) levels were also obtained in patients with PAH. The mean age of patients was 46.4 ± 14.8 years, 76% women, and 16 patients (43%) had schistosomiasis. Sixteen patients (43%) were in WHO class III or IV under specific treatment for PAH. The overall 6MWT distance was 441 meters, and the BNP levels were 80 pg/mL. Patients with PAH more commonly presented with LV diastolic dysfunction and impairment of RV function when compared to controls. LV global longitudinal and radial strains were lower in patients than in controls (-17.9 ± 2.8 vs. -20.5 ± 1.9; P < 0.001 and 30.8 ± 10.5 vs. 49.8 ± 15.4; P < 0.001, respectively). After excluding septal values, LV longitudinal and radial strains remained lower in patients than in controls. The independent factors associated with global LV longitudinal strain were LV ejection fraction, RV fractional area change, and tricuspid annular systolic motion. This study showed impaired LV contractility in patients with PAH assessed by speckle tracking strain, irrespective of ventricular septal involvement. Global LV longitudinal strain was associated independently with RV fractional area change and tricuspid annular systolic motion, after adjustment for LV ejection fraction. © 2016, Wiley Periodicals, Inc.

  4. Anterior transposition of the radial nerve--a cadaveric study.

    Science.gov (United States)

    Yakkanti, Madhusudhan R; Roberts, Craig S; Murphy, Joshua; Acland, Robert D

    2008-01-01

    The radial nerve is at risk during the posterior plating of the humerus. The purpose of this anatomic study was to assess the extent of radial nerve dissection required for anterior transposition through the fracture site (transfracture anterior transposition). A cadaver study was conducted approaching the humerus by a posterior midline incision. The extent of dissection of the nerve necessary for plate fixation of the humerus fracture was measured. An osteotomy was created to model a humeral shaft fracture at the spiral groove (OTA classification 12-A2, 12-A3). The radial nerve was then transposed anterior to the humeral shaft through the fracture site. The additional dissection of the radial nerve and the extent of release of soft tissue from the humerus shaft to achieve the transposition were measured. Plating required a dissection of the radial nerve 1.78 cm proximal and 2.13 cm distal to the spiral groove. Transfracture anterior transposition of the radial nerve required an average dissection of 2.24 cm proximal and 2.68 cm distal to the spiral groove. The lateral intermuscular septum had to be released for 2.21 cm on the distal fragment to maintain laxity of the transposed nerve. Transfracture anterior transposition of the radial nerve before plating is feasible with dissection proximal and distal to the spiral groove and elevation of the lateral intermuscular septum. Potential clinical advantages of this technique include enhanced fracture site visualization, application of broader plates, and protection of the radial nerve during the internal fixation.

  5. A New Filtering Algorithm Utilizing Radial Velocity Measurement

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-feng; DU Zi-cheng; PAN Quan

    2005-01-01

    Pulse Doppler radar measurements consist of range, azimuth, elevation and radial velocity. Most of the radar tracking algorithms in engineering only utilize position measurement. The extended Kalman filter with radial velocity measureneut is presented, then a new filtering algorithm utilizing radial velocity measurement is proposed to improve tracking results and the theoretical analysis is also given. Simulation results of the new algorithm, converted measurement Kalman filter, extended Kalman filter are compared. The effectiveness of the new algorithm is verified by simulation results.

  6. Photoelectric Radial Velocities, Paper XIX Additional Spectroscopic ...

    Indian Academy of Sciences (India)

    ian velocity curve that does justice to the measurements, but it cannot be expected to have much predictive power. Key words. Stars: late-type—stars: radial velocities—spectroscopic binaries—orbits. 0. Preamble. The 'Redman K stars' are a lot of seventh-magnitude K stars whose radial velocities were first observed by ...

  7. Bilateral Internal Carotid Artery Occlusion, External Carotid Artery Stenosis, and Vertebral Artery Kinking: May It Be Asymptomatic?

    Science.gov (United States)

    Fatic, Nikola; Jaffer, Usman; Ivana, Saicic; Gordana, Globarevic-Vukcevic; Markovic, Dragan; Kostic, Dusan; Davidovic, Lazar

    2017-10-01

    The clinical spectrum of internal carotid artery occlusion ranges from being a completely asymptomatic occlusion to a devastating stroke or death. The prevalence of asymptomatic internal carotid artery occlusion is unknown, particularly for bilateral occlusion. The distal branches of the external carotid artery anastomose with distal branches of the internal carotid artery provide important sources of collateral circulation to the brain. Stenosis of the external carotid artery with ipsilateral/bilateral internal occlusion may result in ischemic sequelae. Coiling or kinking of the vertebral artery is a rare morphological entity that is infrequently reported because it remains asymptomatic and has no clinical relevance. Currently, there is little evidence to support management strategies for this disease entity and no official recommendations for asymptomatic bilateral carotid artery occlusion. We present a case of a 62-year-old female with asymptomatic bilateral internal carotid artery occlusion, bilateral external carotid artery stenoses, and bilateral kinking of the vertebral artery at the V2 segment, who has been successfully managed conservatively for over 5 years. An individualized approach to management of patients with bilateral internal carotid artery occlusion, especially in combination with external carotid artery stenosis and elongation malformations of the vertebral artery is key to a successful strategy. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Linear theory radial and nonradial pulsations of DA dwarf stars

    International Nuclear Information System (INIS)

    Starrfield, S.; Cox, A.N.; Hodson, S.; Pesnell, W.D.

    1982-01-01

    The Los Alamos stellar envelope and radial linear non-adiabatic computer code, along with a new Los Alamos non-radial code are used to investigate the total hydrogen mass necessary to produce the non-radial instability of DA dwarfs

  9. Numerical Investigation of Pulse Wave Propagation in Arteries Using Fluid Structure Interaction Capabilities

    Directory of Open Access Journals (Sweden)

    Hisham Elkenani

    2017-01-01

    Full Text Available The aim of this study is to present a reliable computational scheme to serve in pulse wave velocity (PWV assessment in large arteries. Clinicians considered it as an indication of human blood vessels’ stiffness. The simulation of PWV was conducted using a 3D elastic tube representing an artery. The constitutive material model specific for vascular applications was applied to the tube material. The fluid was defined with an equation of state representing the blood material. The onset of a velocity pulse was applied at the tube inlet to produce wave propagation. The Coupled Eulerian-Lagrangian (CEL modeling technique with fluid structure interaction (FSI was implemented. The scaling of sound speed and its effect on results and computing time is discussed and concluded that a value of 60 m/s was suitable for simulating vascular biomechanical problems. Two methods were used: foot-to-foot measurement of velocity waveforms and slope of the regression line of the wall radial deflection wave peaks throughout a contour plot. Both methods showed coincident results. Results were approximately 6% less than those calculated from the Moens-Korteweg equation. The proposed method was able to describe the increase in the stiffness of the walls of large human arteries via the PWV estimates.

  10. Worldwide Trends in Multi-arterial Coronary Artery Bypass Grafting Surgery 2004-2014: A Tale of 2 Continents.

    Science.gov (United States)

    Schwann, Thomas A; Tatoulis, James; Puskas, John; Bonnell, Mark; Taggart, David; Kurlansky, Paul; Jacobs, Jeffery P; Thourani, Vinod H; O'Brien, Sean; Wallace, Amelia; Engoren, Milo C; Tranbaugh, Robert F; Habib, Robert H

    2017-01-01

    Recent evidence shows that multi-arterial coronary artery bypass grafting (MABG) based on bilateral internal thoracic (BITA) or left internal thoracic (LITA) and radial artery (RA) improves long-term outcomes compared with single arterial coronary artery bypass grafting (SABG) (LITA + saphenous vein graft). How this evidence affected the worldwide use of MABG, if at all, is not well defined. Accordingly, we report 10-year temporal trends of MABG utilization from 2 continents. A study population of 1,683,434 non-emergent, primary, isolated LITA-based coronary artery bypass grafting (CABG) (≥2 grafts) patients was derived from the Society of Thoracic Surgeons (STS) (1,307,528 (79.5%) of 1,644,388 isolated CABG; total 1179 centers) and the Australia New Zealand Cardiothoracic (ANZ) Databases (34,213 (87%) of 39,046 isolated CABG; 24 centers) between 2004 and 2014. Patients were excluded based on the following: (1) no LITA, (2) if arterial grafts were other than RA or ITA, or (3) if grafting data were missing. The 3 MABG groups were LITA + RA, BITA, and BITA + RA, each with or without supplemental vein grafts. Grafting trends and their associated patient demographics were analyzed. SABG (89.3% STS, 51.4% ANZ) was the most common grafting strategy. MABG was most frequently accomplished by LITA + RA: (STS: 6.1%; ANZ: 42.6%), followed by BITA: (STS: 4.1%; ANZ: 4.3%), while ≥3 (BITA + RA) was rare in the STS (0.5%), but more common in ANZ (5.9%). In the STS, between 2004 and 2014, SABG rates systematically increased from 85.2% to 91.7%, BITA grafting was essentially unchanged from 3.6% to 4.3%, while RA use decreased systematically from 10.5% to 3.7%. In the ANZ, SABG rates increased from 17.3% to 51.4%, BITA grafting decreased from 6.3% to 3.6%, while RA grafting decreased from 65.8% to 39.0%. Compared with SABG patients, BITA patients were younger (STS: median age 59 vs 66, P 30 kg/m 2 ) in STS (37% vs 42%, P < 0.001), more obese in ANZ

  11. Superselective intra-arterial infusion via the superficial temporal artery and occipital artery for gingival carcinoma of the mandible. Simultaneous catheter placement to the maxillary artery and facial artery

    International Nuclear Information System (INIS)

    Iwai, Toshinori; Mitsudo, Kenji; Fukui, Takafumi

    2009-01-01

    Superselective intra-arterial infusion via the superficial temporal artery (STA) has become useful for oral cancer. Approaching via the occipital artery (OA) enables superselective intra-arterial infusion when catheter placement via the STA is impossible. Therefore, simultaneous catheter placement via the STA and OA is possible. We report a surgical method of simultaneous catheter placement via the STA and OA to achieve retrograde superselective intra-arterial infusion for gingival carcinoma of the mandible. Preoperatively, three-dimensional computed tomography angiography was performed to identify the route of the external carotid artery and branches such as the STA, OA, maxillary artery, and facial artery (FA). Thirteen patients with mandibular gingival cancer underwent catheter placement via the STA and OA under local anesthesia. Catheter placement via the STA and OA was superselectively successful in all the patients. The mean operating time was 150.8 min. Catheter placed to the FA via the OA was dislocated during the treatment in one patient, and so the catheter was replaced. This method is useful to enable superselective intra-arterial chemotherapy to the whole gingival carcinoma of the mandible from the start of treatment compared with approaching via the STA. (author)

  12. Increased rate of arterial stiffening with obesity in adolescents: a five-year follow-up study.

    Directory of Open Access Journals (Sweden)

    Frida Dangardt

    Full Text Available BACKGROUND: We prospectively and longitudinally determined the effects of childhood obesity on arterial stiffening and vascular wall changes. Changes in arterial stiffness measured as pulse wave velocity (PWV and vascular morphology of the radial (RA and dorsal pedal arteries (DPA were examined in obese adolescents compared to lean subjects in a 5-year follow-up study. METHODOLOGY/PRINCIPAL FINDINGS: A total of 28 obese subjects and 14 lean controls participated in both baseline (14 years old and follow-up studies. PWV was measured by tonometer (SphygmoCor® and recorded at RA and carotid artery, respectively. Intima thickness (IT, intima-media thickness (IMT and RA and DPA diameters were measured using high-resolution ultrasound (Vevo 770™. Over the course of 5 years, PWV increased by 25% in the obese subjects as compared to 3% in the controls (p = 0.01. Diastolic blood pressure (DBP increased by 23% in the obese subjects as opposed to 6% in controls (p = 0.009. BMI increased similarly in both groups, as did the IT and IMT. The change in PWV was strongly associated to the baseline BMI z -score (r = 0.51, p<0.001, as was the change in DBP (r = 0.50, p = 0.001. CONCLUSIONS/SIGNIFICANCE: During the transition from early to late adolescence, there was a general increase in arterial stiffness, which was aggravated by childhood obesity. The increase in arterial stiffness and DBP after 5 years was closely correlated to the baseline BMI z -score, indicating that childhood obesity has an adverse impact on vascular adaptation.

  13. Retinal artery occlusion during carotid artery stenting with distal embolic protection device.

    Science.gov (United States)

    Kohara, Kotaro; Ishikawa, Tatsuya; Kobayashi, Tomonori; Kawamata, Takakazu

    2018-01-01

    Retinal artery occlusion associated with carotid artery stenosis is well known. Although it can also occur at the time of carotid artery stenting, retinal artery occlusion via the collateral circulation of the external carotid artery is rare. We encountered two cases of retinal artery occlusion that were thought to be caused by an embolus from the external carotid artery during carotid artery stenting with a distal embolic protection device for the internal carotid artery. A 71-year-old man presented with central retinal artery occlusion after carotid artery stenting using the Carotid Guardwire PS and a 77-year-old man presented with branch retinal artery occlusion after carotid artery stenting using the FilterWire EZ. Because additional new cerebral ischaemic lesions were not detected in either case by postoperative diffusion-weighted magnetic resonance imaging, it was highly likely that the debris that caused retinal artery occlusion passed through not the internal carotid artery but collaterals to retinal arteries from the external carotid artery, which was not protected by a distal embolic protection device. It is suggested that a distal protection device for the internal carotid artery alone cannot prevent retinal artery embolisation during carotid artery stenting and protection of the external carotid artery is important to avoid retinal artery occlusion.

  14. Effect of the radial electric field on turbulence

    International Nuclear Information System (INIS)

    Carreras, B.A.; Lynch, V.E.

    1990-01-01

    For many years, the neoclassical transport theory for three- dimensional magnetic configurations, such as magnetic mirrors, ELMO Bumpy Tori (EBTs), and stellarators, has recognized the critical role of the radial electric field in the confinement. It was in these confinement devices that the first experimental measurements of the radial electric field were made and correlated with confinement losses. In tokamaks, the axisymmetry implies that the neoclassical fluxes are ambipolar and, as a consequence, independent of the radial electric field. However, axisymmetry is not strict in a tokamak with turbulent fluctuations, and near the limiter ambipolarity clearly breaks down. Therefore, the question of the effect of the radial electric field on tokamak confinement has been raised in recent years. In particular, the radial electric field has been proposed to explain the transition from L-mode to H-mode confinement. There is some initial experimental evidence supporting this type of explanation, although there is not yet a self-consistent theory explaining the generation of the electric field and its effect on the transport. Here, a brief review of recent results is presented. 27 refs., 4 figs

  15. A user's evaluation of radial flow HEPA filters

    International Nuclear Information System (INIS)

    Purcell, J.A.

    1992-07-01

    High efficiency particulate air (HEPA) filters of rectangular cross section have been used to remove particulates and the associated radioactivity from air ventilation streams since the advent of nuclear materials processing. Use of round axial flow HEPA filters is also longstanding. The advantages of radial flow filters in a circular configuration have been well demonstrated in UKAEA during the last 5--7 years. An evaluation of radial flow filters for fissile process gloveboxes reveals several substantial benefits in addition to the advantages claimed in UKAEA Facilities. The radial flow filter may be provided in a favorable geometry resulting in improved criticality safety. The filter configuration lends to in-place testing at the glovebox to exhaust duct interface. This will achieve compliance with DOE Order 6430.1A, Section 99.0.2. Preliminary testing at SRS for radial flow filters manufactured by Flanders Filters, Inc. revealed compliance in all the usual specifications for filtration efficiency, pressure differential and materials of construction. An evaluation, further detailed in this report, indicates that the radial flow HEPA filter should be considered for inclusion in new ventilation system designs

  16. Radial extension of drift waves in presence of velocity profiles

    International Nuclear Information System (INIS)

    Sen, S.; Weiland, J.

    1994-01-01

    The effect of a radially varying poloidal velocity field on the recently found radially extended toroidal drift waves is investigated analytically. The role of velocity curvature (υ φ '') is found to have robust effects on the radial model structure of the mode. For a positive value of the curvature (Usually found in the H-mode edges) the radial model envelope, similar to the sheared slab case, becomes fully outgoing. The mode is therefore stable. On the other hand, for a negative value of the curvature (usually observed in the L-mode edges) all the characteristics of conventional drift waves return back. The radial mode envelope reduces to a localized Gaussian shape and the mode is therefore unstable again for typical (magnetic) shear values in tokamaks. Velocity shear (υ φ ??) on the other hand is found to have rather insignificant role both in determining the radial model structure and stability

  17. Vertebral artery origin stent placement with distal protection: technical and clinical results.

    Science.gov (United States)

    Qureshi, A I; Kirmani, J F; Harris-Lane, P; Divani, A A; Ahmed, S; Ebrihimi, A; Al Kawi, A; Janjua, N

    2006-05-01

    To report the feasibility, safety, and 1-month results of performing stent placement for vertebral origin stenosis with the use of a distal protection device. Distal protection devices have been shown to reduce the number of cerebral emboli and subsequent ischemic events when used as adjuncts to percutaneous carotid intervention; however, one case of the use of a distal protection device for vertebral artery has been reported in the literature. We retrospectively determined rates of technical success and 1-month stroke or death associated with stent placement by using distal protection (Filter EX; Boston Scientific, Natick, Mass) in patients with symptomatic vertebral artery origin stenosis. Technical success was defined as successful deployment of distal protection device and stent at target lesion followed by successful retrieval of the device and a final residual stenosis of less than 30%. Other outcomes ascertained included any stroke, death, and semiquantitative assessment of particulate material retained by the filter device. The mean age of the 12 treated patients was 68 years (range, 52-88 years) and the group included 9 men and 3 women. The mean percentage of vertebral artery origin stenosis was 71 +/- 6%. Femoral and radial approaches were used in 9 and 3 cases, respectively. Technical success was achieved in 11 of the 12 patients in whom distal protection device placement was attempted. Postprocedure residual stenosis was 5 +/- 4%. Eight devices held macroscopically visible embolic debris (large and small amounts in 3 and 5 devices, respectively). No stroke or death was observed in the 1-month follow-up. The present study demonstrates the feasibility of performing stent placement for vertebral artery origin stenosis by using a distal protection device. Further studies are required to determine the effectiveness of this approach for vertebral artery origin atherosclerosis.

  18. Systemic Arterial-to-Pulmonary Artery Shunt Utilization

    African Journals Online (AJOL)

    multiruka1

    In certain circumstances, such as cyanotic neonates with tetralogy of Fallot (4) or cyanotic patients with. Tetralogy of Fallot and hypoplastic pulmonary arteries. (5), better outcomes are obtained if definitive surgery. (total correction or palliation) is preceded by creation of a systemic arterial-to-pulmonary artery shunt (SAPAS).

  19. Free radial forearm flap versatility for the head and neck and lower extremity

    International Nuclear Information System (INIS)

    Chicarilli, Z.N.; Ariyan, S.; Cuono, C.B.

    1986-01-01

    Microsurgical techniques have developed numerous territories suitable for free tissue transfer. However, the demand for thin cutaneous resurfacing limits the choice of flaps available to the reconstructive microsurgeon. The radial forearm flap is a thin, axial, fasciocutaneous flap, offering pliable cutaneous resurfacing, with or without sensation. We have used 15 flaps to reconstruct defects in the head and neck and lower extremity resulting from burns, blunt and avulsive trauma, radiation necrosis, and tumor ablation. Two flaps (15 percent) developed venous congestion and were salvaged by reoperation. One retrograde flap (7.5 percent) developed partial necrosis from arterial insufficiency. Neural re-innervation was successful in two out of three patients in whom it was attempted. Two patients (15%) sustained minor donor site skin graft loss that healed secondarily. In our series of predominantly older patients the donor sites have been relatively inconspicuous at one year follow-up. A functional restoration was achieved in all patients

  20. A novel structure of permanent-magnet-biased radial hybrid magnetic bearing

    International Nuclear Information System (INIS)

    Sun Jinji; Fang Jiancheng

    2011-01-01

    The paper proposes a novel structure for a permanent-magnet-biased radial hybrid magnetic bearing. Based on the air gap between the rotor and stator of traditional radial hybrid magnetic bearings, a subsidiary air gap is first constructed between the permanent magnets and the inner magnetic parts. Radial magnetic bearing makes X and Y magnetic fields independent of each other with separate stator poles, and the subsidiary air gap makes control flux to a close loop. As a result, magnetic field coupling of the X and Y channels is decreased significantly by the radial hybrid magnetic bearing and makes it easier to design control systems. Then an external rotor structure is designed into the radial hybrid magnetic bearing. The working principle of the radial hybrid magnetic bearing and its mathematical model is discussed. Finally, a non-linear magnetic network method is proposed to analyze the radial hybrid magnetic bearing. Simulation results indicate that magnetic fields in the two channels of the proposed radial hybrid magnetic bearing decouple well from each other.

  1. A novel structure of permanent-magnet-biased radial hybrid magnetic bearing

    Energy Technology Data Exchange (ETDEWEB)

    Sun Jinji, E-mail: sunjinji@aspe.buaa.edu.c [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, 100191 (China); Fang Jiancheng [Key Laboratory of Fundamental Science for National Defense, Novel Inertial Instrument and Navigation System Technology, School of Instrument Science and Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, 100191 (China)

    2011-01-15

    The paper proposes a novel structure for a permanent-magnet-biased radial hybrid magnetic bearing. Based on the air gap between the rotor and stator of traditional radial hybrid magnetic bearings, a subsidiary air gap is first constructed between the permanent magnets and the inner magnetic parts. Radial magnetic bearing makes X and Y magnetic fields independent of each other with separate stator poles, and the subsidiary air gap makes control flux to a close loop. As a result, magnetic field coupling of the X and Y channels is decreased significantly by the radial hybrid magnetic bearing and makes it easier to design control systems. Then an external rotor structure is designed into the radial hybrid magnetic bearing. The working principle of the radial hybrid magnetic bearing and its mathematical model is discussed. Finally, a non-linear magnetic network method is proposed to analyze the radial hybrid magnetic bearing. Simulation results indicate that magnetic fields in the two channels of the proposed radial hybrid magnetic bearing decouple well from each other.

  2. Detonation in supersonic radial outflow

    KAUST Repository

    Kasimov, Aslan R.

    2014-11-07

    We report on the structure and dynamics of gaseous detonation stabilized in a supersonic flow emanating radially from a central source. The steady-state solutions are computed and their range of existence is investigated. Two-dimensional simulations are carried out in order to explore the stability of the steady-state solutions. It is found that both collapsing and expanding two-dimensional cellular detonations exist. The latter can be stabilized by putting several rigid obstacles in the flow downstream of the steady-state sonic locus. The problem of initiation of standing detonation stabilized in the radial flow is also investigated numerically. © 2014 Cambridge University Press.

  3. Metabolic liver function measured in vivo by dynamic (18)F-FDGal PET/CT without arterial blood sampling.

    Science.gov (United States)

    Horsager, Jacob; Munk, Ole Lajord; Sørensen, Michael

    2015-01-01

    Metabolic liver function can be measured by dynamic PET/CT with the radio-labelled galactose-analogue 2-[(18)F]fluoro-2-deoxy-D-galactose ((18)F-FDGal) in terms of hepatic systemic clearance of (18)F-FDGal (K, ml blood/ml liver tissue/min). The method requires arterial blood sampling from a radial artery (arterial input function), and the aim of this study was to develop a method for extracting an image-derived, non-invasive input function from a volume of interest (VOI). Dynamic (18)F-FDGal PET/CT data from 16 subjects without liver disease (healthy subjects) and 16 patients with liver cirrhosis were included in the study. Five different input VOIs were tested: four in the abdominal aorta and one in the left ventricle of the heart. Arterial input function from manual blood sampling was available for all subjects. K*-values were calculated using time-activity curves (TACs) from each VOI as input and compared to the K-value calculated using arterial blood samples as input. Each input VOI was tested on PET data reconstructed with and without resolution modelling. All five image-derived input VOIs yielded K*-values that correlated significantly with K calculated using arterial blood samples. Furthermore, TACs from two different VOIs yielded K*-values that did not statistically deviate from K calculated using arterial blood samples. A semicircle drawn in the posterior part of the abdominal aorta was the only VOI that was successful for both healthy subjects and patients as well as for PET data reconstructed with and without resolution modelling. Metabolic liver function using (18)F-FDGal PET/CT can be measured without arterial blood samples by using input data from a semicircle VOI drawn in the posterior part of the abdominal aorta.

  4. Índice para la evaluación de las reflexiones mediante análisis de la onda de pulso radial

    Directory of Open Access Journals (Sweden)

    Gustavo J. Meschino

    2008-01-01

    Full Text Available En el presente trabajo se analiza la posibilidad de utilizar un parámetro obtenido del registro de la onda de pulso radial, el ancho de la onda sistólica, que es más sencillo de medir aún que el índice de aumentación radial y que complementaría a este último en la evaluación de la amplitud de la reflexión sistólica, directamente relacionada con el grado de disfunción endotelial y el fenómeno de aumentación aórtica.Se efectuó un estudio poblacional sobre 120 varones normotensos sanos con edades entre 17 y 65 años. Se obtuvo en ellos el registro de la onda de pulso radial en base al registro del movimiento de las paredes de la arteria mediante un sensor capacitivo aplicado sobre la zona de palpación del pulso. Cada registro se procesó y normalizó en amplitud y se calculó el índice de aumentación radial y el ancho de la onda sistólica al 50% de su altura máxima.Se halló que individuos con el mismo índice de aumentación poseían distintos valores de ancho de onda sistólica, lo cual evidencia distintos valores de amplitud de la onda reflejada. Ambos parámetros aumentaron con la edad y su correlación r resultó de 0,9.Se propone la utilización del ancho de la onda sistólica como un índice de envejecimiento alternativo, que permitiría evaluar el sistema arterial cuando la medición del índice de aumentación resultara dificultosa o la comparación entre individuos fuera ambigua.

  5. Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application

    International Nuclear Information System (INIS)

    Gastounioti, A; Stoitsis, J S; Nikita, K S; Golemati, S

    2013-01-01

    Valid risk stratification for carotid atherosclerotic plaques represents a crucial public health issue toward preventing fatal cerebrovascular events. Although motion analysis (MA) provides useful information about arterial wall dynamics, the identification of motion-based risk markers remains a significant challenge. Considering that the ability of a motion estimator (ME) to handle changes in the appearance of motion targets has a major effect on accuracy in MA, we investigated the potential of adaptive block matching (ABM) MEs, which consider changes in image intensities over time. To assure the validity in MA, we optimized and evaluated the ABM MEs in the context of a specially designed in silico framework. ABM FIRF2 , which takes advantage of the periodicity characterizing the arterial wall motion, was the most effective ABM algorithm, yielding a 47% accuracy increase with respect to the conventional block matching. The in vivo application of ABM FIRF2 revealed five potential risk markers: low movement amplitude of the normal part of the wall adjacent to the plaques in the radial (RMA PWL ) and longitudinal (LMA PWL ) directions, high radial motion amplitude of the plaque top surface (RMA PTS ), and high relative movement, expressed in terms of radial strain (RSI PL ) and longitudinal shear strain (LSSI PL ), between plaque top and bottom surfaces. The in vivo results were reproduced by OF LK(WLS) and ABM KF-K2 , MEs previously proposed by the authors and with remarkable in silico performances, thereby reinforcing the clinical values of the markers and the potential of those MEs. Future in vivo studies will elucidate with confidence the full potential of the markers. (paper)

  6. Radial nerve dysfunction (image)

    Science.gov (United States)

    The radial nerve travels down the arm and supplies movement to the triceps muscle at the back of the upper arm. ... the wrist and hand. The usual causes of nerve dysfunction are direct trauma, prolonged pressure on the ...

  7. Variable stator radial turbine

    Science.gov (United States)

    Rogo, C.; Hajek, T.; Chen, A. G.

    1984-01-01

    A radial turbine stage with a variable area nozzle was investigated. A high work capacity turbine design with a known high performance base was modified to accept a fixed vane stagger angle moveable sidewall nozzle. The nozzle area was varied by moving the forward and rearward sidewalls. Diffusing and accelerating rotor inlet ramps were evaluated in combinations with hub and shroud rotor exit rings. Performance of contoured sidewalls and the location of the sidewall split line with respect to the rotor inlet was compared to the baseline. Performance and rotor exit survey data are presented for 31 different geometries. Detail survey data at the nozzle exit are given in contour plot format for five configurations. A data base is provided for a variable geometry concept that is a viable alternative to the more common pivoted vane variable geometry radial turbine.

  8. A registry-based randomized trial comparing radial and femoral approaches in women undergoing percutaneous coronary intervention: the SAFE-PCI for Women (Study of Access Site for Enhancement of PCI for Women) trial.

    Science.gov (United States)

    Rao, Sunil V; Hess, Connie N; Barham, Britt; Aberle, Laura H; Anstrom, Kevin J; Patel, Tejan B; Jorgensen, Jesse P; Mazzaferri, Ernest L; Jolly, Sanjit S; Jacobs, Alice; Newby, L Kristin; Gibson, C Michael; Kong, David F; Mehran, Roxana; Waksman, Ron; Gilchrist, Ian C; McCourt, Brian J; Messenger, John C; Peterson, Eric D; Harrington, Robert A; Krucoff, Mitchell W

    2014-08-01

    This study sought to determine the effect of radial access on outcomes in women undergoing percutaneous coronary intervention (PCI) using a registry-based randomized trial. Women are at increased risk of bleeding and vascular complications after PCI. The role of radial access in women is unclear. Women undergoing cardiac catheterization or PCI were randomized to radial or femoral arterial access. Data from the CathPCI Registry and trial-specific data were merged into a final study database. The primary efficacy endpoint was Bleeding Academic Research Consortium type 2, 3, or 5 bleeding or vascular complications requiring intervention. The primary feasibility endpoint was access site crossover. The primary analysis cohort was the subgroup undergoing PCI; sensitivity analyses were conducted in the total randomized population. The trial was stopped early for a lower than expected event rate. A total of 1,787 women (691 undergoing PCI) were randomized at 60 sites. There was no significant difference in the primary efficacy endpoint between radial or femoral access among women undergoing PCI (radial 1.2% vs. 2.9% femoral, odds ratio [OR]: 0.39; 95% confidence interval [CI]: 0.12 to 1.27); among women undergoing cardiac catheterization or PCI, radial access significantly reduced bleeding and vascular complications (0.6% vs. 1.7%; OR: 0.32; 95% CI: 0.12 to 0.90). Access site crossover was significantly higher among women assigned to radial access (PCI cohort: 6.1% vs. 1.7%; OR: 3.65; 95% CI: 1.45 to 9.17); total randomized cohort: (6.7% vs. 1.9%; OR: 3.70; 95% CI: 2.14 to 6.40). More women preferred radial access. In this pragmatic trial, which was terminated early, the radial approach did not significantly reduce bleeding or vascular complications in women undergoing PCI. Access site crossover occurred more often in women assigned to radial access. (SAFE-PCI for Women; NCT01406236). Copyright © 2014 American College of Cardiology Foundation. Published by Elsevier Inc

  9. Central Artery Stiffness, Baroreflex Sensitivity, and Brain White Matter Neuronal Fiber Integrity in Older Adults

    Science.gov (United States)

    Tarumi, Takashi; de Jong, Daan L.K.; Zhu, David C.; Tseng, Benjamin Y.; Liu, Jie; Hill, Candace; Riley, Jonathan; Womack, Kyle B.; Kerwin, Diana R.; Lu, Hanzhang; Cullum, C. Munro; Zhang, Rong

    2015-01-01

    Cerebral hypoperfusion elevates the risk of brain white matter (WM) lesions and cognitive impairment. Central artery stiffness impairs baroreflex, which controls systemic arterial perfusion, and may deteriorate neuronal fiber integrity of brain WM. The purpose of this study was to examine the associations among brain WM neuronal fiber integrity, baroreflex sensitivity (BRS), and central artery stiffness in older adults. Fifty-four adults (65±6 years) with normal cognitive function or mild cognitive impairment (MCI) were tested. The neuronal fiber integrity of brain WM was assessed from diffusion metrics acquired by diffusion tensor imaging. BRS was measured in response to acute changes in blood pressure induced by bolus injections of vasoactive drugs. Central artery stiffness was measured by carotid-femoral pulse wave velocity (cfPWV). The WM diffusion metrics including fractional anisotropy (FA) and radial (RD) and axial (AD) diffusivities, BRS, and cfPWV were not different between the control and MCI groups. Thus, the data from both groups were combined for subsequent analyses. Across WM, fiber tracts with decreased FA and increased RD were associated with lower BRS and higher cfPWV, with many of the areas presenting spatial overlap. In particular, the BRS assessed during hypotension was strongly correlated with FA and RD when compared with hypertension. Executive function performance was associated with FA and RD in the areas that correlated with cfPWV and BRS. These findings suggest that baroreflex-mediated control of systemic arterial perfusion, especially during hypotension, may play a crucial role in maintaining neuronal fiber integrity of brain WM in older adults. PMID:25623500

  10. Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions

    Directory of Open Access Journals (Sweden)

    Marcia Jacomelli

    Full Text Available ABSTRACT Objective: Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. Methods: We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy, we used fluoroscopy. Results: Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm and 19 masses (mean diameter, 4.1 ± 0.9 cm. The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS. Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7% and bronchial bleeding, which was controlled bronchoscopically (in 9.3%. Conclusions: Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions.

  11. Seguimento a longo prazo de pacientes submetidos à revascularização do miocárdio com uso exclusivo de enxertos arteriais Long-term follow-up of patients undergone coronary artery bypass grafting with exclusive use of arterial grafts

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Abdouni

    2008-12-01

    Full Text Available OBJETIVO: Avaliar os resultados a longo prazo da cirurgia de revascularização do miocárdio com o uso exclusivo de enxertos arteriais em pacientes com doença coronariana triarterial. MÉTODOS: Avaliamos 136 pacientes submetidos a cirurgia de revascularização do miocárdio isolada, no período janeiro de 1995 e dezembro de 1997. Utilizaram-se 353 enxertos para revascularizar 449 artérias (média: 3,30 por paciente. Foram utilizadas a artéria torácica interna esquerda (99,2%, artéria torácica interna direita (56,6%, artéria radial (87,5%, artéria gastroepiplóica direita (20,5% e uma artéria epigástrica inferior. Setenta e seis (55,8% pacientes receberam enxertos compostos (em "Y" e 66 (48,5% receberam anastomoses seqüenciais. RESULTADOS: A mortalidade hospitalar foi de 4,4%. No seguimento a longo prazo, (9,5 a 12,8 anos, 82,1% dos pacientes não apresentaram nenhum evento cardíaco. Vinte (17,9% pacientes necessitaram de reinternação por eventos cardiovasculares; 15 com angina e cinco com infarto agudo do miocárdio, sendo que três apresentaram insuficiência cardíaca associada. Oito (7,1% pacientes necessitaram de reintervenção por doença coronariana, sendo um reoperado e os demais submetidos a angioplastia com stent. A probabilidade estimada livre de eventos cardíacos foi de 98,2%, 95,4% e 84,2% em 1, 5 e 10 anos, respectivamente. Ocorreram 16 (14,2% óbitos tardios, sendo quatro deles (3,6% de causa cardíaca. Sobrevida actuarial em 12,8 anos por todas as causas foi de 85% neste grupo. CONCLUSÃO: Revascularização do miocárdio com o uso exclusivo de enxertos arteriais em pacientes com doença coronariana triarterial é um procedimento seguro, com bons resultados a longo prazo.OBJECTIVE: To evaluate the long-term results of the coronary artery bypass grafting with exclusive use of arterial grafts for patients with triple vessel disease. METHODS: We evaluated 136 patients who underwent isolated coronary artery bypass

  12. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  13. Natural control capabilities of robotic hands by hand amputated subjects.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Caputo, Barbara; Muller, Henning

    2014-01-01

    People with transradial hand amputations who own a myoelectric prosthesis currently have some control capabilities via sEMG. However, the control systems are still limited and not natural. The Ninapro project is aiming at helping the scientific community to overcome these limits through the creation of publicly available electromyography data sources to develop and test machine learning algorithms. In this paper we describe the movement classification results gained from three subjects with an homogeneous level of amputation, and we compare them with the results of 40 intact subjects. The number of considered subjects can seem small at first sight, but it is not considering the literature of the field (which has to face the difficulty of recruiting trans-radial hand amputated subjects). The classification is performed with four different classifiers and the obtained balanced classification rates are up to 58.6% on 50 movements, which is an excellent result compared to the current literature. Successively, for each subject we find a subset of up to 9 highly independent movements, (defined as movements that can be distinguished with more than 90% accuracy), which is a deeply innovative step in literature. The natural control of a robotic hand in so many movements could lead to an immediate progress in robotic hand prosthetics and it could deeply change the quality of life of amputated subjects.

  14. Radial distribution of ions in pores with a surface charge

    NARCIS (Netherlands)

    Stegen, J.H.G. van der; Görtzen, J.; Kuipers, J.A.M.; Hogendoorn, J.A.; Versteeg, G.F.

    2001-01-01

    A sorption model applicable to calculate the radial equilibrium concentrations of ions in the pores of ion-selective membranes with a pore structure is developed. The model is called the radial uptake model. Because the model is applied to a Nafion sulfonic layer with very small pores and the radial

  15. The Matlab Radial Basis Function Toolbox

    Directory of Open Access Journals (Sweden)

    Scott A. Sarra

    2017-03-01

    Full Text Available Radial Basis Function (RBF methods are important tools for scattered data interpolation and for the solution of Partial Differential Equations in complexly shaped domains. The most straight forward approach used to evaluate the methods involves solving a linear system which is typically poorly conditioned. The Matlab Radial Basis Function toolbox features a regularization method for the ill-conditioned system, extended precision floating point arithmetic, and symmetry exploitation for the purpose of reducing flop counts of the associated numerical linear algebra algorithms.

  16. Stellar Angular Momentum Distributions and Preferential Radial Migration

    Science.gov (United States)

    Wyse, Rosemary; Daniel, Kathryne J.

    2018-04-01

    I will present some results from our recent investigations into the efficiency of radial migration in stellar disks of differing angular momentum distributions, within a given adopted 2D spiral disk potential. We apply to our models an analytic criterion that determines whether or not individual stars are in orbits that could lead to radial migration around the corotation resonance. We couch our results in terms of the local stellar velocity dispersion and find that the fraction of stars that could migrate radially decreases as the velocity dispersion increases. I will discuss implications and comparisons with the results of other approaches.

  17. Research on Radial Vibration of a Circular Plate

    Directory of Open Access Journals (Sweden)

    Wei Liu

    2016-01-01

    Full Text Available Radial vibration of the circular plate is presented using wave propagation approach and classical method containing Bessel solution and Hankel solution for calculating the natural frequency theoretically. In cylindrical coordinate system, in order to obtain natural frequency, propagation and reflection matrices are deduced at the boundaries of free-free, fixed-fixed, and fixed-free using wave propagation approach. Furthermore, radial phononic crystal is constructed by connecting two materials periodically for the analysis of band phenomenon. Also, Finite Element Simulation (FEM is adopted to verify the theoretical results. Finally, the radial and piezoelectric effects on the band are also discussed.

  18. Radial-probe EBUS for the diagnosis of peripheral pulmonary lesions.

    Science.gov (United States)

    Jacomelli, Marcia; Demarzo, Sergio Eduardo; Cardoso, Paulo Francisco Guerreiro; Palomino, Addy Lidvina Mejia; Figueiredo, Viviane Rossi

    2016-01-01

    Conventional bronchoscopy has a low diagnostic yield for peripheral pulmonary lesions. Radial-probe EBUS employs a rotating ultrasound transducer at the end of a probe that is passed through the working channel of the bronchoscope. Radial-probe EBUS facilitates the localization of peripheral pulmonary nodules, thus increasing the diagnostic yield. The objective of this study was to present our initial experience using radial-probe EBUS in the diagnosis of peripheral pulmonary lesions at a tertiary hospital. We conducted a retrospective analysis of 54 patients who underwent radial-probe EBUS-guided bronchoscopy for the investigation of pulmonary nodules or masses between February of 2012 and September of 2013. Radial-probe EBUS was performed with a flexible 20-MHz probe, which was passed through the working channel of the bronchoscope and advanced through the bronchus to the target lesion. For localization of the lesion and for collection procedures (bronchial brushing, transbronchial needle aspiration, and transbronchial biopsy), we used fluoroscopy. Radial-probe EBUS identified 39 nodules (mean diameter, 1.9 ± 0.7 cm) and 19 masses (mean diameter, 4.1 ± 0.9 cm). The overall sensitivity of the method was 66.7% (79.5% and 25.0%, respectively, for lesions that were visible and not visible by radial-probe EBUS). Among the lesions that were visible by radial-probe EBUS, the sensitivity was 91.7% for masses and 74.1% for nodules. The complications were pneumothorax (in 3.7%) and bronchial bleeding, which was controlled bronchoscopically (in 9.3%). Radial-probe EBUS shows a good safety profile, a low complication rate, and high sensitivity for the diagnosis of peripheral pulmonary lesions. A broncoscopia convencional possui baixo rendimento diagnóstico para lesões pulmonares periféricas. A ecobroncoscopia radial (EBUS radial) emprega um transdutor ultrassonográfico rotatório na extremidade de uma sonda que é inserida no canal de trabalho do broncoscópio. O EBUS

  19. Radial vibration and ultrasonic field of a long tubular ultrasonic radiator.

    Science.gov (United States)

    Shuyu, Lin; Zhiqiang, Fu; Xiaoli, Zhang; Yong, Wang; Jing, Hu

    2013-09-01

    The radial vibration of a metal long circular tube is studied analytically and its electro-mechanical equivalent circuit is obtained. Based on the equivalent circuit, the radial resonance frequency equation is derived. The theoretical relationship between the radial resonance frequency and the geometrical dimensions is studied. Finite element method is used to simulate the radial vibration and the radiated ultrasonic field and the results are compared with those from the analytical method. It is concluded that the radial resonance frequency for a solid metal rod is larger than that for a metal tube with the same outer radius. The radial resonance frequencies from the analytical method are in good agreement with those from the numerical method. Based on the acoustic field analysis, it is concluded that the long metal tube with small wall thickness is superior to that with large wall thickness in producing radial vibration and ultrasonic radiation. Therefore, it is expected to be used as an effective radial ultrasonic radiator in ultrasonic sewage treatment, ultrasonic antiscale and descaling and other ultrasonic liquid handling applications. Copyright © 2013 Elsevier B.V. All rights reserved.

  20. Pulmonary Arterial Hypertension and Neonatal Arterial Switch Surgery for Correction of Transposition of the Great Arteries.

    Science.gov (United States)

    Domínguez Manzano, Paula; Mendoza Soto, Alberto; Román Barba, Violeta; Moreno Galdó, Antonio; Galindo Izquierdo, Alberto

    2016-09-01

    There are few reports of the appearance of pulmonary arterial hypertension following arterial switch surgery in the neonatal period to correct transposition of the great arteries. We assessed the frequency and clinical pattern of this complication in our series of patients. Our database was reviewed to select patients with transposition of the great arteries corrected by neonatal arterial switch at our hospital and who developed pulmonary hypertension over time. We identified 2 (1.3%) patients with transposition of the great arteries successfully repaired in the first week of life who later experienced pulmonary arterial hypertension. The first patient was a 7-year-old girl diagnosed with severe pulmonary hypertension at age 8 months who did not respond to medical treatment and required lung transplantation. The anatomic pathology findings were consistent with severe pulmonary arterial hypertension. The second patient was a 24-month-old boy diagnosed with severe pulmonary hypertension at age 13 months who did not respond to medical therapy. Pulmonary hypertension is a rare but very severe complication that should be investigated in all patients with transposition of the great arteries who have undergone neonatal arterial switch, in order to start early aggressive therapy for affected patients, given the poor therapeutic response and poor prognosis involved. Copyright © 2016 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  1. Radial Fuzzy Systems

    Czech Academy of Sciences Publication Activity Database

    Coufal, David

    2017-01-01

    Roč. 319, 15 July (2017), s. 1-27 ISSN 0165-0114 R&D Projects: GA MŠk(CZ) LD13002 Institutional support: RVO:67985807 Keywords : fuzzy systems * radial functions * coherence Subject RIV: BA - General Mathematics OBOR OECD: Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8) Impact factor: 2.718, year: 2016

  2. Velocidades radiales en Collinder 121

    Science.gov (United States)

    Arnal, M.; Morrell, N.

    Se han llevado a cabo observaciones espectroscópicas de unas treinta estrellas que son posibles miembros del cúmulo abierto Collinder 121. Las mismas fueron realizadas con el telescopio de 2.15m del Complejo Astronómico El Leoncito (CASLEO). El análisis de las velocidades radiales derivadas del material obtenido, confirma la realidad de Collinder 121, al menos desde el punto de vista cinemático. La velocidad radial baricentral (LSR) del cúmulo es de +17 ± 3 km.s-1. Esta velocidad coincide, dentro de los errores, con la velocidad radial (LSR) de la nebulosa anillo S308, la cual es de ~20 ± 10 km.s-1. Como S308 se encuentra físicamente asociada a la estrella Wolf-Rayet HD~50896, es muy probable que esta última sea un miembro de Collinder 121. Desde un punto de vista cinemático, la supergigante roja HD~50877 (K3Iab) también pertenecería a Collinder 121. Basándonos en la pertenencia de HD~50896 a Collinder 121, y en la interacción encontrada entre el viento de esta estrella y el medio interestelar circundante a la misma, se estima para este cúmulo una distancia del orden de 1 kpc.

  3. Radial supports of face motors with slack compensation

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsova, I I; Gelman, A B; Krekina, T V

    1982-01-01

    The design of a radial support of a face motor with slack compensation is described, and gives the results of field tests which confirm the performance capacity of the experimental support both from the viewpoint of durability, and in relation to preventing radial slack of the face motor shaft.

  4. Queratotomía radial versus miniqueratotomía radial: Experiencia en el Hospital "Ramón Pando Ferrer" Radial keratotomy versus radial minikeratotomy: Experience in "Ramón Pando Ferrer" Hospital

    Directory of Open Access Journals (Sweden)

    José Edilberto Pacheco Serrano

    2000-06-01

    Full Text Available La miniqueratotomía radial se viene realizando desde 1995. Se plantea que incisiones más cortas tienen el mismo efecto y producen menos debilidad corneal, ya que disminuye la susceptibilidad a sufrir complicaciones graves provenientes de traumas de la vida cotidiana. Esta idea nos motivó a realizar un estudio para observar el comportamiento de incisiones más cortas en nuestro centro y, en caso de resultados positivos, implementar la técnica de manera que nuestros pacientes puedan beneficiarse de ella. Se comparan resultados de la aplicación de dos técnicas quirúrgicas refractivas para corrección de miopía entre leve y moderada. Se seleccionaron 38 pacientes entre 20 y 40 años de edad, con miopías entre -2 y -6 dioptrías y astigmatismo no mayor a -0,75 dioptrías. Se realizó queratotomía radial convencional en el ojo derecho y miniqueratotomía radial en el ojo izquierdo del mismo paciente. Las variaciones obtenidas en promedio fueron, en el ojo derecho: la esfera (en dioptrías D de -3,38 a -0,32, cilindro de -0,48 a -0,45 D, la queratometría de 44,75 a 41,21 D. En el ojo izquierdo: la esfera de -3,38 D a -0,44 D, cilindro de -0,44 D a -0,38 D, la queratometría de 44,83 a 41,80 D. Hubo una mejoría de la agudeza visual sin cristales de 0,61 en el ojo derecho y 0,59 en el ojo izquierdo. Las dos técnicas no mostraron diferencias estadísticamente significativas, con el beneficio de que la nueva técnica disminuye el riesgo de ruptura postraumática, según la bibliografía revisada, a causa de la menor injuria corneal.In this hospital, radial keratotomy is performed sice 1995. We propose that shorter incisions have some effect and cause less corneal weakness, since dicreases susceptibility to severe complications from traumata of daily life. This notion encouraged us to carry out a study to observe behaviour of shorter incisions in our service, and in the event of positive results, implementation of the technique so that our

  5. Pseudarthrosis of radial shaft with dislocation of heads of radial and ulnar bones (case report

    Directory of Open Access Journals (Sweden)

    M. E. Puseva

    2013-01-01

    Full Text Available The authors presented a rare clinical case - the injury of forearm complicated by the formation of the pseudarthrosis of the radial shaft in combination with old dislocation of heads the radius and ulna. The differentiated approach to the choice of surgical tactics was proposed, which consists of several consistent stages: taking free autotransplant from the crest of iliac bone, resection of pseudarthrosis of radius with replacement of the bone defect by the graft for restoration of anatomic length, conducting combined strained osteosynthesis and elimination of dislocation of a head of radial and ulnar bones by transosseous osteosynthesis. The chosen treatment strategy allowed to restore the anatomy and function of the upper extremity.

  6. Brachial artery repair using the basilic vein as a reliable conduit in a 3-year-old child

    Directory of Open Access Journals (Sweden)

    Hyunyoung G. Kim

    2017-04-01

    Full Text Available A supracondylar fracture of the humerus is the most common upper extremity fracture in children with concurrent neurovascular complications. However, bypass grafting in the management of a pediatric open elbow dislocation with an arterial injury has rarely been reported in the literature. Hence, an adequate conduit for a vessel graft interposition remains questionable when a primary anastomosis is limited in an arterial reconstruction. The purpose of this study is to present a brachial artery reconstruction in a 3-year-old patient with an open supracondylar fracture of the humerus. In the clinical and surgical examination of the patient, an open wound in the left antecubital fossa presented with accompanying brachial artery injury. To repair the artery, a reverse end-to-end anastomosis was conducted using basilic vein graft from the ipsilateral arm under general anesthesia. The patient had palpable radial pulses in the postoperative clinical examination and was discharged without complications. The great saphenous vein (GSV has proven to be the most common and the best conduit for arterial reconstruction of the upper extremity in the adult patients. However, the GSV graft is known to have the propensity for becoming aneurysmal in pediatric patients. Some studies have demonstrated the basilic vein as a suitable conduit in pediatric patients, in that it has durable patency, fewer branches, size compatibility for anastomosis, and proximity to the brachial artery. Our case confirms the safety of using this autogenous vein from within the zone of injury for arterial reconstruction, after a supracondylar humeral fracture. The management of pediatric elbow fractures accompanying vascular injuries can be technically demanding due to relatively small, delicate structures and concurrent neurovascular network. Nonetheless, a vascular injury should be treated with high level of suspicion and immediate intervention to avoid any limb ischemia or loss. In

  7. Manufacturing of Precision Forgings by Radial Forging

    International Nuclear Information System (INIS)

    Wallner, S.; Harrer, O.; Buchmayr, B.; Hofer, F.

    2011-01-01

    Radial forging is a multi purpose incremental forging process using four tools on the same plane. It is widely used for the forming of tool steels, super alloys as well as titanium- and refractory metals. The range of application goes from reducing the diameters of shafts, tubes, stepped shafts and axels, as well as for creating internal profiles for tubes in Near-Net-Shape and Net-Shape quality. Based on actual development of a weight optimized transmission input shaft, the specific features of radial forging technology is demonstrated. Also a Finite Element Model for the simulation of the process is shown which leads to reduced pre-processing effort and reduced computing time compared to other published simulation methods for radial forging. The finite element model can be applied to quantify the effects of different forging strategies.

  8. Radially truncated galactic discs

    NARCIS (Netherlands)

    Grijs, R. de; Kregel, M.; Wesson, K H

    2000-01-01

    Abstract: We present the first results of a systematic analysis of radially truncatedexponential discs for four galaxies of a sample of disc-dominated edge-onspiral galaxies. Edge-on galaxies are very useful for the study of truncatedgalactic discs, since we can follow their light distributions out

  9. Lower extremity revascularization without preoperative contrast arteriography: experience with duplex ultrasound arterial mapping in 485 cases.

    Science.gov (United States)

    Ascher, Enrico; Hingorani, Anil; Markevich, Natalia; Costa, Tatiana; Kallakuri, Shreedhar; Khanimoy, Yuri

    2002-01-01

    This study reviews our experience with duplex ultrasound arterial mapping (DUAM) for preoperative evaluation in 466 patients (262 men) who underwent 485 lower extremity revascularization procedures from January 1, 1998 to May 30, 2001. Preoperative imaging consisted of DUAM alone in 449 procedures and DUAM and contrast angiography (CA) in 36. An attempt to image from the distal aorta to the pedal arteries was made in all the patients. The selection of optimal inflow and outflow bypasses anastomotic sites was based on a schematic drawing following DUAM examination. Inflow disease was also assessed by intraoperative pressure gradient (IPG) between the distal anastomosis and radial arteries, and completion arteriography of the runoff vessels was obtained, which was correlated with the preoperative findings. Indications for surgery were severe claudication in 91 (19%) limbs, tissue loss in 197 (40%), rest pain in 113 (23%), acute ischemia in 46 (10%), popliteal aneurysm in 18 (4%), superficial femoral artery aneurysm in 1, abdominal aortic aneurysm with claudication in 1, and failing graft in 18 (4%). Age ranged from 30 to 97 years (mean 72 +/- 12 (SD) years) and risk factors such as diabetes, hypertension, use of tobacco, coronary artery disease, and end-stage renal disease were present in 45%, 45%, 44%, 44%, and 13% of the patients, respectively. One hundred twenty-one (25%) limbs had at least 1 previous ipsilateral revascularization. The mean DUAM time was 66 +/- 20 (SD) min (30-150 min). Additional preoperative imaging was deemed necessary in 36 cases due to extensive ulcers, edema, severe arterial wall calcification, and very poor runoff. The distal anastomosis was to the popliteal artery in 173 cases and to the tibial and pedal arteries in 255. Inflow procedures to the femoral arteries, embolectomy, thrombectomy, balloon angioplasty, and patch angioplasty accounted for the remaining 57 cases. Overall, 6-, 12-, and -24- month secondary patency rates were 86%, 80

  10. Novel Use of a Pneumatic Compression Device for Haemostasis of Haemodialysis Fistula Access Catheterisation Sites

    Energy Technology Data Exchange (ETDEWEB)

    O’Reilly, Michael K., E-mail: moreilly1@mater.ie; Ryan, David; Sugrue, Gavin; Geoghegan, Tony; Lawler, Leo P.; Farrelly, Cormac T. [Mater Misericordiae University Hospital, Department of Interventional Radiology (Ireland)

    2016-12-15

    PurposeTransradial pneumatic compression devices can be used to achieve haemostasis following radial artery puncture. This article describes a novel technique for acquiring haemostasis of arterio-venous haemodialysis fistula access sites without the need for suture placement using one such compression device.Materials and MethodsA retrospective review of fistulograms with or without angioplasty/thrombectomy in a single institution was performed. 20 procedures performed on 12 patients who underwent percutaneous intervention of failing or thrombosed arterio-venous fistulas (AVF) had 27 puncture sites. Haemostasis was achieved using a pneumatic compression device at all access sites. Procedure details including size of access sheath, heparin administration and complications were recorded.ResultsTwo diagnostic fistulograms, 14 fistulograms and angioplasties and four thrombectomies were performed via access sheaths with an average size (±SD) of 6 Fr (±1.12). IV unfractionated heparin was administered in 11 of 20 procedures. Haemostasis was achieved in 26 of 27 access sites following 15–20 min of compression using the pneumatic compression device. One case experienced limited bleeding from an inflow access site that was successfully treated with reinflation of the device for a further 5 min. No other complication was recorded.ConclusionsHaemostasis of arterio-venous haemodialysis fistula access sites can be safely and effectively achieved using a pneumatic compression device. This is a technically simple, safe and sutureless technique for acquiring haemostasis after AVF intervention.

  11. Aberrant overian artery originating from the Ilolumbar artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Ji Eun; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University College of Medicine, Bucheon Hospital, Bucheon (Korea, Republic of)

    2016-05-15

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE.

  12. Aberrant overian artery originating from the Ilolumbar artery: A case report

    International Nuclear Information System (INIS)

    Lee, Ji Eun; Lee, Jae Myeong

    2016-01-01

    Here, we report a case of a 30-year-old woman who presented with primary postpartum hemorrhage due to uterine atony. She received uterine artery embolization (UAE). During left internal iliac arteriography, an aberrant left ovarian artery originating from the left iliolumbar artery was visualized. The aberrant left ovarian artery was connected to the left uterine artery via prominent collateral vessels. It supplied a significant amount of blood to the fundus of the uterus. Bilateral hypertrophied uterine arteries were embolized very carefully so that the embolic material did not reflux into the aberrant left ovarian artery. After the procedure, her vaginal bleeding was successfully controlled. Accurate understanding of anatomical variations of the ovarian artery is essential to avoid failure in controlling postpartum hemorrhage with UAE

  13. Radial velocity observations of VB10

    Science.gov (United States)

    Deshpande, R.; Martin, E.; Zapatero Osorio, M. R.; Del Burgo, C.; Rodler, F.; Montgomery, M. M.

    2011-07-01

    VB 10 is the smallest star known to harbor a planet according to the recent astrometric study of Pravdo & Shaklan [1]. Here we present near-infrared (J-band) radial velocity of VB 10 performed from high resolution (R~20,000) spectroscopy (NIRSPEC/KECK II). Our results [2] suggest radial velocity variability with amplitude of ~1 km/s, a result that is consistent with the presence of a massive planet companion around VB10 as found via long-term astrometric monitoring of the star by Pravdo & Shaklan. Employing an entirely different technique we verify the results of Pravdo & Shaklan.

  14. Radial electron beam laser excitation: the REBLE report

    International Nuclear Information System (INIS)

    Ramirez, J.J.; Prestwich, K.R.

    1978-10-01

    The results of an investigation of techniques to generate high-power radially converging electron beams and the application of these beams to gas lasers is discussed. The design and performance of the REBLE accelerator that was developed for this program is presented. Reliable operation of the radial diode has been obtained at levels up to 1 MV, 200 kA, and 20 ns. It has been demonstrated that the anode current density can be made uniform to better than 15% over 1000 cm 2 areas with 100 to 250 A/cm 2 intensities. The measured total and spatially resolved energy deposition of this radial electron beam in various gases is compared with Monte Carlo calculations. In most cases, these codes give an accurate description of the beam transport and energy deposition. With the electron beam pumping xenon gas, the amplitude of xenon excimer radiation (1720 A 0 ) was radially uniform to within the experimental uncertainty. The efficiency of converting deposited electron beam energy to xenon excimer radiation was 20%

  15. Cerebellar arteries originating from the internal carotid artery: angiographic evaluation and embryologic explanations

    International Nuclear Information System (INIS)

    Lee, Jae Young; Han, Moon Hee; Yu, In Gyu; Chang, Ki Hyun; Kim, Eui Jong; Kim, Dae Ho

    1997-01-01

    To find and describe the cerebellar arteries arising from the internal carotid artery, explain them embryologically, and evaluate their clinical implication. To determine the point in the internal carotid artery from which the cereballar artery arose anomalously, consecutive angiographic studies performed in the last three years were reviewed. The distribution of such anomalous cerebellar arteries, the point in the internal carotid artery from which the anomalous vessels originated, and associated findings were analyzed. Five anomalous origins of cerebellar arteries arising arising directly from the internal carotid artery were found in five patients. Three anterior inferior cerebellar arteries (AICA) and one common trunk of an AICA and a posterior inferior cerebellar artery (PICA) were found to originate from the internal carotid artery at a point close to the origin of the primitive trigeminal artery. A PICA arose from an artery presenting a course similar to the proatlantal intersegmental artery. Intracranial aneurysms in two patients, Moyamoya disease in one, and facial arteriovenous malformation in one. In our series, AICAs supplied from the arteries considered to be persistent trigeminal artery variants were the most common type. A correlation between type of anomalous cerebellar artery and type of carotid-vertebrobasilar anastomosis may exist. Cerebellar arteries originating anomalously from the internal carotid artery seem to occur as a result of the persistence of carotid-vertebrobasilar anastomoses associated with incomplete fusion of the longitudinal neural arteries. An understanding of these anomalous cerebellar arteries may help prevent accidents during therapeutic embolization and surgical treatment, as well as misinterpretation

  16. Radial scar/complex sclerosing lesion of the breast--value of ultrasound.

    Science.gov (United States)

    Grunwald, S; Heyer, H; Kühl, A; Schwesinger, G; Schimming, A; Köhler, G; Ohlinger, R

    2007-04-01

    Although benign, radial scar/complex sclerosing adenosis is a lesion which histopathologically resembles tubular carcinoma. On physical examination, it is difficult to distinguish radial scar from a malignant tumour. Mammography cannot differentiate radial scar from malignancy. This clinical study aims to delineate the role of preoperative ultrasonography with emphasis on the question whether ultrasonography could lower the number of false-positive readings and therefore the number of open biopsies required. In this examination, we present the clinical, mammographic, ultrasonographic, and histopathological features of 6 cases of radial scars. Although most authors describe radial scars as non-palpable, 2 of 6 lesions were indeed palpable. On mammograms, radial scars have a spiculated appearance, a feature observed in all of our cases. Numerous ultrasonographic characteristics are listed in the literature, but ultrasonography is not reported to have clear-cut advantages. Although this study did not elucidate any unique ultrasonographic features to characterise these lesions, the analysis of all ultrasonographic results made us recognise a set of "nearly specific ultrasonographic features" of radial scars. Current B-mode imaging does not appear to lead to the desirable reduction of the rate of unnecessary open biopsies.

  17. Radial Structure Scaffolds Convolution Patterns of Developing Cerebral Cortex

    Directory of Open Access Journals (Sweden)

    Mir Jalil Razavi

    2017-08-01

    Full Text Available Commonly-preserved radial convolution is a prominent characteristic of the mammalian cerebral cortex. Endeavors from multiple disciplines have been devoted for decades to explore the causes for this enigmatic structure. However, the underlying mechanisms that lead to consistent cortical convolution patterns still remain poorly understood. In this work, inspired by prior studies, we propose and evaluate a plausible theory that radial convolution during the early development of the brain is sculptured by radial structures consisting of radial glial cells (RGCs and maturing axons. Specifically, the regionally heterogeneous development and distribution of RGCs controlled by Trnp1 regulate the convex and concave convolution patterns (gyri and sulci in the radial direction, while the interplay of RGCs' effects on convolution and axons regulates the convex (gyral convolution patterns. This theory is assessed by observations and measurements in literature from multiple disciplines such as neurobiology, genetics, biomechanics, etc., at multiple scales to date. Particularly, this theory is further validated by multimodal imaging data analysis and computational simulations in this study. We offer a versatile and descriptive study model that can provide reasonable explanations of observations, experiments, and simulations of the characteristic mammalian cortical folding.

  18. Plasma magnesium concentration in patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Kotlinska-Hasiec, Edyta; Makara-Studzinska, Marta; Czajkowski, Marek; Rzecki, Ziemowit; Olszewski, Krzysztof; Stadnik, Adam; Pilat, Jacek; Rybojad, Beata; Dabrowski, Wojciech

    2017-05-11

    [b]Introduction[/b]. Magnesium (Mg) plays a crucial role in cell physiology and its deficiency may cause many disorders which often require intensive treatment. The aim of this study was to analyse some factors affecting preoperative plasma Mg concentration in patients undergoing coronary artery bypass grafting (CABG). [b]Materials and method[/b]. Adult patients scheduled for elective CABG with cardio-pulmonary bypass (CPB) under general anaesthesia were studied. Plasma Mg concentration was analysed before surgery in accordance with age, domicile, profession, tobacco smoking and preoperative Mg supplementation. Blood samples were obtained from the radial artery just before the administration of anaesthesia. [b]Results. [/b]150 patients were studied. Mean preoperative plasma Mg concentration was 0.93 ± 0.17 mmol/L; mean concentration in patients - 1.02 ± 0.16; preoperative Mg supplementation was significantly higher than in patients without such supplementation. Moreover, intellectual workers supplemented Mg more frequently and had higher plasma Mg concentration than physical workers. Plasma Mg concentration decreases in elderly patients. Patients living in cities, on average, had the highest plasma Mg concentration. Smokers had significantly lower plasma Mg concentration than non-smokers. [b]Conclusions. [/b]1. Preoperative magnesium supplementation increases its plasma concentration. 2. Intellectual workers frequently supplement magnesium. 3. Smoking cigarettes decreases plasma magnesium concentration.

  19. Aberrant ovarian artery arising from the common Iliac artery: Case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Won Kyung [Dept. of Radiology, Soonchunhyang University Bucheon Hospital, Soonchunhyang University College of Medicine, Bucheon (Korea, Republic of); Yang, Seung Boo; Lee, Jae Myeong [Dept. of Radiology, Soonchunhyang University Gumi Hospital, Soonchunhyang University College of Medicine, Gumi (Korea, Republic of); Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo [Dept. of Radiology, Soonchunhyang University Seoul Hospital, Soonchunhyang University College of Medicine, Seoul (Korea, Republic of)

    2013-01-15

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  20. Aberrant ovarian artery arising from the common Iliac artery: Case report

    International Nuclear Information System (INIS)

    Kim, Won Kyung; Yang, Seung Boo; Lee, Jae Myeong; Goo, Dong Erk; Kim, Yong Jae; Chang, Yun Woo

    2013-01-01

    A 46-year-old Vietnamese woman received embolization therapy in order to control postpartum hemorrhage. Angiography revealed an aberrant ovarian artery arising from the right common iliac artery. Superselective catheterization and subsequent embolization of the aberrant ovarian artery and bilateral uterine arteries were performed. Precise knowledge of the anatomic variations of the ovarian artery is important for successful embolization.

  1. Radial Pressure Pulse and Heart Rate Variability in Heat- and Cold-Stressed Humans

    Directory of Open Access Journals (Sweden)

    Chin-Ming Huang

    2011-01-01

    Full Text Available This study aims to explore the effects of heat and cold stress on the radial pressure pulse (RPP and heart rate variability (HRV. The subjects immersed their left hand into 45°C and 7°C water for 2 minutes. Sixty healthy subjects (age 25±4 yr; 29 men and 31 women were enrolled in this study. All subjects underwent the supine temperature measurements of the bilateral forearms, brachial arterial blood pressure, HRV and RPP with a pulse analyzer in normothermic conditions, and thermal stresses. The power spectral low-frequency (LF and high-frequency (HF components of HRV decreased in the heat test and increased in the cold test. The heat stress significantly reduced radial augmentation index (AIr (P<.05, but the cold stress significantly increased AIr (P<.01. The spectral energy of RPP did not show any statistical difference in 0∼10 Hz region under both conditions, but in the region of 10∼50 Hz, there was a significant increase (P<.01 in the heat test and a significant decrease in the cold test (P<.01. The changes in AIr induced by heat and cold stress were significantly negatively correlated with the spectral energy in the region of 10∼50 Hz (SE10−50 Hz but not in the region of 0∼10 Hz (SE0−10 Hz. The results demonstrated that the SE10−50 Hz, which only possessed a small percentage in total pulse energy, presented more physiological characteristics than the SE0−10 Hz under the thermal stresses.

  2. Radial Pressure Pulse and Heart Rate Variability in Heat- and Cold-Stressed Humans

    Science.gov (United States)

    Huang, Chin-Ming; Chang, Hsien-Cheh; Kao, Shung-Te; Li, Tsai-Chung; Wei, Ching-Chuan; Chen, Chiachung; Liao, Yin-Tzu; Chen, Fun-Jou

    2011-01-01

    This study aims to explore the effects of heat and cold stress on the radial pressure pulse (RPP) and heart rate variability (HRV). The subjects immersed their left hand into 45°C and 7°C water for 2 minutes. Sixty healthy subjects (age 25 ± 4 yr; 29 men and 31 women) were enrolled in this study. All subjects underwent the supine temperature measurements of the bilateral forearms, brachial arterial blood pressure, HRV and RPP with a pulse analyzer in normothermic conditions, and thermal stresses. The power spectral low-frequency (LF) and high-frequency (HF) components of HRV decreased in the heat test and increased in the cold test. The heat stress significantly reduced radial augmentation index (AIr) (P < .05), but the cold stress significantly increased AIr (P < .01). The spectral energy of RPP did not show any statistical difference in 0 ~ 10 Hz region under both conditions, but in the region of 10 ~ 50 Hz, there was a significant increase (P < .01) in the heat test and a significant decrease in the cold test (P < .01). The changes in AIr induced by heat and cold stress were significantly negatively correlated with the spectral energy in the region of 10 ~ 50 Hz (SE10−50 Hz) but not in the region of 0 ~ 10 Hz (SE0−10 Hz). The results demonstrated that the SE10−50 Hz, which only possessed a small percentage in total pulse energy, presented more physiological characteristics than the SE0−10 Hz under the thermal stresses. PMID:21113292

  3. Access to the ophthalmic artery by retrograde approach through the posterior communicating artery for intra-arterial chemotherapy of retinoblastoma

    Energy Technology Data Exchange (ETDEWEB)

    Pham, Chi-Tuan; Blanc, Raphael; Pistocchi, Silvia; Bartolini, Bruno; Piotin, Michel [Fondation Rothschild Hospital, Department of Interventional Neuroradiology, Paris (France); Lumbroso-Le Rouic, Livia [Institut Curie, Department of Ocular Oncology, Paris (France)

    2012-08-15

    Intra-arterial infusion of chemotherapy into the ophthalmic artery for treatment of retinoblastoma has been realized after catheterization of the internal carotid and temporary balloon occlusion beyond the orifice of the ophthalmic artery, or more recently after superselective canulation of the ophthalmic artery by a microcatheter. The superselective catheterization of the ophthalmic artery could be cumbersome because of the implantation of the ostium on the carotid siphon or because of the tortuosity of the carotid siphon. We report our experience of using a retrograde approach through the posterior communicating artery that allows a more direct angle of access to the origin of the ophthalmic artery. (orig.)

  4. Arterial scan versus radiographic angiography in detection of shallow arterial ulcers

    International Nuclear Information System (INIS)

    Pollak, E.W.; Webber, M.M.; Cragin, M.D.; Wolfman, E.F. Jr.

    1977-01-01

    A comparison of 99m-technetium albumin aggregated arterial scan and radiographic angiography for detection of shallow intimal carotid artery ulcerations was made in a series of 12 anesthetized dogs, having a total of 16 acute arterial ulcerations. Radiographic angiography showed positive findings related to presence of stenosis or mural thrombosis in 12 instances. Direct visualization of ulceration was only exceptionally encountered. Arterial scan detected 14 of 16 intimal ulcers. The radionuclide method was reliable even in absence of stenosis or when only minimal mural thrombosis was present. Moreover, autopsy scan of the isolated arterial segments detected all 16 intimal lesions. These results indicate that the arterial scan was a more reliable method for detection of shallow arterial ulcers in this experimental model than radiographic angiography, especially when arterial lumen stenosis or mural thrombosis was minimal or absent

  5. Prediction of parent artery of anterior communicating artery aneurysm on CT angiography

    International Nuclear Information System (INIS)

    Chung, Jin Young; Han, Tae Il; Kim, Dae Hong; Han, Hyun Young; Kim, Hyun Jung; Song, Mun Kab

    1999-01-01

    To determine whether CT angiography can predict the parent artery of an anterior communicating aneurysm on the basis of characteristics of the aneurysm and precommunication anterior cerebral artery. Eighteen patients with anterior communication aneurysm were studied prospectively using CT angiography and conventional angiography. The parent artery of an aneurysm was predicted by evaluating aneurysm neck location, direction of aneurysm projection, and size of the precommunicating anterior cerebral artery, as seen on CT angiography. A somatom Plus-4 spiral CT scanner was used and shaded-surface display three-dimensional images were constructed. Aneurysm neck was located near the parent artery in 12 cases(66.7%), and aneurysm projection was against the parent artery in 11 cases(61.1%). The parent artery of the anterior cerebral artery was larger in 15 cases(83.3%), including ten cases of hypoplasia or agenesis of the contralateral anterior cerebral artery. In 17 of 18 aneurysms(94.4%) the parent artery seen on DSA was correctly predicted by CT angiography. The parent artery of an anterior communicating aneurysm can be predicted by evaluating aneurysm neck location, direction of aneurysm projection, and precommunicating anterior cerebral artery, as seen on CT angiography

  6. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. EL POSIBLE ATRAPAMIENTO DE LA ARTERIA ULNAR POR EL TERCER FASCÍCULO DEL MÚSCULO PRONADOR TERES

    Directory of Open Access Journals (Sweden)

    Satheesha Nayak B

    2012-11-01

    Full Text Available Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea.

  7. Fuel radial design using Path Relinking

    International Nuclear Information System (INIS)

    Campos S, Y.

    2007-01-01

    The present work shows the obtained results when implementing the combinatory optimization technique well-known as Path Re linking (Re-linkage of Trajectories), to the problem of the radial design of nuclear fuel assemblies, for boiling water reactors (BWR Boiling Water Reactor by its initials in English), this type of reactors is those that are used in the Laguna Verde Nucleo electric Central, Veracruz. As in any other electric power generation plant of that make use of some fuel to produce heat and that it needs each certain time (from 12 to 14 months) to make a supply of the same one, because this it wears away or it burns, in the nucleolectric plants to this activity is denominated fuel reload. In this reload different activities intervene, among those which its highlight the radial and axial designs of fuel assemblies, the patterns of control rods and the multi cycles study, each one of these stages with their own complexity. This work was limited to study in independent form the radial design, without considering the other activities. These phases are basic for the fuel reload design and of reactor operation strategies. (Author)

  8. Numerical Simulation of Hydraulic Fracture Propagation Guided by Single Radial Boreholes

    Directory of Open Access Journals (Sweden)

    Tiankui Guo

    2017-10-01

    Full Text Available Conventional hydraulic fracturing is not effective in target oil development zones with available wellbores located in the azimuth of the non-maximum horizontal in-situ stress. To some extent, we think that the radial hydraulic jet drilling has the function of guiding hydraulic fracture propagation direction and promoting deep penetration, but this notion currently lacks an effective theoretical support for fracture propagation. In order to verify the technology, a 3D extended finite element numerical model of hydraulic fracturing promoted by the single radial borehole was established, and the influences of nine factors on propagation of hydraulic fracture guided by the single radial borehole were comprehensively analyzed. Moreover, the term ‘Guidance factor (Gf’ was introduced for the first time to effectively quantify the radial borehole guidance. The guidance of nine factors was evaluated through gray correlation analysis. The experimental results were consistent with the numerical simulation results to a certain extent. The study provides theoretical evidence for the artificial control technology of directional propagation of hydraulic fracture promoted by the single radial borehole, and it predicts the guidance effect of a single radial borehole on hydraulic fracture to a certain extent, which is helpful for planning well-completion and fracturing operation parameters in radial borehole-promoted hydraulic fracturing technology.

  9. Radial collective flow in heavy-ion collisions at intermediate energies

    International Nuclear Information System (INIS)

    Borderie, B.

    1996-11-01

    The production of radial collective flow is associated with collisions leading to sources which undergo multifragmentation/explosion processes. After a theoretical survey of possible causes of production of radial flow, methods used to derive experimental values are discussed. Finally, a large set of data is presented which can be used to study and disentangle the different effects leading to radial collective flow. The dominant role of compression in the lower energy domain is emphasized. (author)

  10. Rotary and radial forcing effects on center-of-mass locomotion dynamics.

    Science.gov (United States)

    Shen, Z H; Larson, P L; Seipel, J E

    2014-09-01

    Rotary and radial forcing are two common actuation methods for legged robots. However, these two orthogonal methods of center-of-mass (CoM) forcing have not been compared as potentially alternative strategies of actuation. In this paper, we compare the CoM stability and energetics of running with rotary and radial actuation through the simulation of two models: the rotary-forced spring-loaded inverted pendulum (rotary-forced-SLIP), and the radially-forced-SLIP. We model both radial and rotary actuation in the simplest way, applying them as a constant force during the stance portion of the gait. A simple application of constant rotary forcing throughout stance is capable of producing fully-asymptotically stable motion; however, a similarly constant application of radial forcing throughout the stance is not capable of producing stable solutions. We then allow both the applied rotary and radial forcing functions to turn on or off based on the occurrence of the mid-stance event, which breaks the symmetry of actuation during stance towards a net forward propulsion. We find that both a rotary force applied in the first half of stance and a radial force applied in the second half of stance, are capable of stabilizing running. Interestingly, these two forcing methods improve the motion stability in different ways. Rotary forcing first reduces then greatly increases the size of the stable parameter region when gradually increased. Radial forcing expands the stable parameter region, but only in a moderate way. Also, it is found that parameter region stabilized by rotary and radial forcing are largely complementary. Overall, rotary forcing can better stabilize running for both constant and event-based forcing functions that were attempted. This indicates that rotary forcing has an inherent capability of stabilizing running, even when minimal time-or-event-or-state feedback is present. Radial forcing, however, tends to be more energy efficient when compared to rotary forcing

  11. Anomalous external carotid artery-internal carotid artery anastomosis in two patients with proximal internal carotid arterial remnants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hun [Dept. of Neurology, Stroke Center, Myongji Hospital, Goyang (Korea, Republic of); Cho, Young Dae; Kang, Hyun Seung; Kim, Jeong Eun; Han, Moon Hee [Seoul National University Hospital, Seoul National University College of Medicine, Seoul (Korea, Republic of); Jung, Seung Chai [Dept. of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ahn, Jun Hyong [Dept. of Neurosurgery, Hallym University Sacred Heart Hospital, Hallym University College of Medicine, Anyang (Korea, Republic of)

    2015-08-15

    Two angiographic instances of anomalous external carotid artery (ECA) and internal carotid artery (ICA) anastomosis are described, each occurring at the C2-3 level and bearing remnants of proximal ICA. The ICA remnant of one patient (identifiable immediately upon bifurcation of the common carotid artery) was hypoplastic, and that of the other patient was an occluded arterial stump. These features are not typical of non-bifurcating ICA. The occipital artery originated from an anomalous connection in one instance and from the main trunk of the ECA (just past the ECA-ICA connection) in the other.

  12. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  13. Fast radial basis functions for engineering applications

    CERN Document Server

    Biancolini, Marco Evangelos

    2017-01-01

    This book presents the first “How To” guide to the use of radial basis functions (RBF). It provides a clear vision of their potential, an overview of ready-for-use computational tools and precise guidelines to implement new engineering applications of RBF. Radial basis functions (RBF) are a mathematical tool mature enough for useful engineering applications. Their mathematical foundation is well established and the tool has proven to be effective in many fields, as the mathematical framework can be adapted in several ways. A candidate application can be faced considering the features of RBF:  multidimensional space (including 2D and 3D), numerous radial functions available, global and compact support, interpolation/regression. This great flexibility makes RBF attractive – and their great potential has only been partially discovered. This is because of the difficulty in taking a first step toward RBF as they are not commonly part of engineers’ cultural background, but also due to the numerical complex...

  14. On improved confinement in mirror plasmas by a radial electric field

    Science.gov (United States)

    Ågren, O.; Moiseenko, V. E.

    2017-11-01

    A weak radial electric field can suppress radial excursions of a guiding center from its mean magnetic surface. The physical origin of this effect is the smearing action by a poloidal E × B rotation, which tend to cancel out the inward and outward radial drifts. A use of this phenomenon may provide larger margins for magnetic field shaping with radial confinement of particles maintained in the collision free idealization. Mirror fields, stabilized by a quadrupolar field component, are of particular interest for their MHD stability and the possibility to control the quasi neutral radial electric field by biased potential plates outside the confinement region. Flux surface footprints on the end tank wall have to be traced to avoid short-circuiting between biased plates. Assuming a robust biasing procedure, moderate voltage demands for the biased plates seems adequate to cure even the radial excursions of Yushmanov ions which could be locally trapped near the mirrors. Analytical expressions are obtained for a magnetic quadrupolar mirror configuration which possesses minimal radial magnetic drifts in the central confinement region. By adding a weak controlled radial quasi-neutral electric field, the majority of gyro centers are predicted to be forced to move even closer to their respective mean magnetic surface. The gyro center radial coordinate is in such a case an accurate approximation for a constant of motion. By using this constant of motion, the analysis is in a Vlasov description extended to finite β. A correspondence between that Vlasov system and a fluid description with a scalar pressure and an electric potential is verified. The minimum B criterion is considered and implications for flute mode stability in the considered magnetic field is analyzed. By carrying out a long-thin expansion to a higher order, the validity of the calculations are extended to shorter and more compact device designs.

  15. Radial Transport and Meridional Circulation in Accretion Disks

    Energy Technology Data Exchange (ETDEWEB)

    Philippov, Alexander A. [Department of Astrophysical Sciences, Princeton University, Ivy Lane, Princeton, NJ 08540 (United States); Rafikov, Roman R., E-mail: sashaph@princeton.edu [Institute for Advanced Study, Einstein Drive, Princeton, NJ 08540 (United States)

    2017-03-10

    Radial transport of particles, elements and fluid driven by internal stresses in three-dimensional (3D) astrophysical accretion disks is an important phenomenon, potentially relevant for the outward dust transport in protoplanetary disks, origin of the refractory particles in comets, isotopic equilibration in the Earth–Moon system, etc. To gain better insight into these processes, we explore the dependence of meridional circulation in 3D disks with shear viscosity on their thermal stratification, and demonstrate a strong effect of the latter on the radial flow. Previous locally isothermal studies have normally found a pattern of the radial outflow near the midplane, switching to inflow higher up. Here we show, both analytically and numerically, that a flow that is inward at all altitudes is possible in disks with entropy and temperature steeply increasing with height. Such thermodynamic conditions may be typical in the optically thin, viscously heated accretion disks. Disks in which these conditions do not hold should feature radial outflow near the midplane, as long as their internal stress is provided by the shear viscosity. Our results can also be used for designing hydrodynamical disk simulations with a prescribed pattern of the meridional circulation.

  16. Detonation in supersonic radial outflow

    KAUST Repository

    Kasimov, Aslan R.; Korneev, Svyatoslav

    2014-01-01

    We report on the structure and dynamics of gaseous detonation stabilized in a supersonic flow emanating radially from a central source. The steady-state solutions are computed and their range of existence is investigated. Two-dimensional simulations

  17. POSSIBLE ENTRAPMENT OF THE ULNAR ARTERY BY THE THIRD HEAD OF PRONATOR TERES MUSCLE. El posible atrapamiento de la arteria ulnar por el tercer fascículo del músculo pronador teres

    Directory of Open Access Journals (Sweden)

    Naveen Kumar

    2016-03-01

    Full Text Available El conocimiento de las variaciones en los alrededores de la fosa cubital es útil para cirujanos ortopédicos, cirujanos plásticos y médicos en general. Observamos las variaciones arteriales y musculares en y alrededor de la fosa cubital. La arteria braquial terminó 2 pulgadas por encima de la base de la fosa cubital. Las arterias radiales y cubitales entraron en la fosa cubital  pasando delante de los tendones de los músculos braquial y bíceps braquial respectivamente. La arteria cubital estaba rodeada por el tercer fascículo del pronador teres, que tuvo su origen en la fascia cubriendo la parte distal del músculo braquial. Este músculo se unió a tendón de pronador teres distalmente y fue suministrado por una rama del nervio mediano. Este músculo podría alterar el flujo sanguíneo en la arteria cubital y puede causar dificultades para el registro de la presión sanguínea. Knowledge of variations at and in the surroundings of cubital fossa is useful for the orthopedic surgeons, plastic surgeons and medical practitioners in general. During routine dissection, we observed arterial and muscular variations in and around the cubital fossa. The brachial artery terminated 2 inches above the base of the cubital fossa. The radial and ulnar arteries entered the cubital fossa by passing in front of the tendons of brachialis and biceps brachii respectively. The ulnar artery was surrounded by the third head of pronator teres which took its origin from the fascia covering the distal part of the brachialis muscle. This muscle joined pronator teres tendon distally and was supplied by a branch of median nerve. This muscle could alter the blood flow in the ulnar artery and may cause difficulties in recording the blood pressure.

  18. THE OCCURRENCE OF THE RADIAL CLUB HAND IN CHILDREN WITH DIFFERENT SYNDROMES

    Directory of Open Access Journals (Sweden)

    Sergey Ivanovich Golyana

    2013-03-01

    Full Text Available Radial club hand is a developmental anomaly of the upper extremity, being characterized as a longitudinal underdevelopment of a forearm and a hand on the radial surface, consisting in a hypo-/ aplazy radial bone and the thumb of various degree of expressiveness. Characteristic symptoms of this developmental anomaly are: shortening and bow-shaped curvature of a forearm, palmar and radial deviation of a hand, underdevelopment of the thumb from its proximal departments and structures, anomaly of development of three-phalanx fingers of a hand (is more often than the 2-4th, violation of a cosmetic condition and functionality of the affected segment. From 2000 for 2012 in FSI SRICO n.a. H.Turner examination and treatment of 23 children with various syndromes at which the radial club hand was revealed are conducted. The main syndromes at which it is revealed radial club hand - Holt-Orama syndrome, TAR- syndrome and VACTERL syndrome. Tactics and techniques of surgical treatment of a radial club hand it various syndromes most often don’t differ from treatment of other types of a radial club hand though demand an individual approach depending on severity and a type of deformation of the upper extremity.

  19. The effect of radial migration on galactic disks

    International Nuclear Information System (INIS)

    Vera-Ciro, Carlos; D'Onghia, Elena; Navarro, Julio; Abadi, Mario

    2014-01-01

    We study the radial migration of stars driven by recurring multi-arm spiral features in an exponential disk embedded in a dark matter halo. The spiral perturbations redistribute angular momentum within the disk and lead to substantial radial displacements of individual stars, in a manner that largely preserves the circularity of their orbits and that results, after 5 Gyr (∼40 full rotations at the disk scale length), in little radial heating and no appreciable changes to the vertical or radial structure of the disk. Our results clarify a number of issues related to the spatial distribution and kinematics of migrators. In particular, we find that migrators are a heavily biased subset of stars with preferentially low vertical velocity dispersions. This 'provenance bias' for migrators is not surprising in hindsight, for stars with small vertical excursions spend more time near the disk plane, and thus respond more readily to non-axisymmetric perturbations. We also find that the vertical velocity dispersion of outward migrators always decreases, whereas the opposite holds for inward migrators. To first order, newly arrived migrators simply replace stars that have migrated off to other radii, thus inheriting the vertical bias of the latter. Extreme migrators might therefore be recognized, if present, by the unexpectedly small amplitude of their vertical excursions. Our results show that migration, understood as changes in angular momentum that preserve circularity, can strongly affect the thin disk, but cast doubts on models that envision the Galactic thick disk as a relic of radial migration.

  20. Rayleigh-Taylor instability of cylindrical jets with radial motion

    International Nuclear Information System (INIS)

    Chen, X.M.; Schrock, V.E.; Peterson, P.F.

    1997-01-01

    Rayleigh-Taylor instability of an interface between fluids with different densities subjected to acceleration normal to itself has interested researchers for almost a century. The classic analyses of a flat interface by Rayleigh and Taylor have shown that this type of instability depends on the direction of acceleration and the density differences of the two fluids. Plesset later analyzed the stability of a spherically symmetric flows (and a spherical interface) and concluded that the instability also depends on the velocity of the interface as well as the direction and magnitude of radial acceleration. The instability induced by radial motion in cylindrical systems seems to have been neglected by previous researchers. This paper analyzes the Rayleigh-Taylor type of instability for a cylindrical surface with radial motions. The results of the analysis show that, like the spherical case, the radial velocity also plays an important role. As an application, the example of a liquid jet surface in an Inertial Confinement Fusion (ICF) reactor design is analyzed. (orig.)

  1. A Novel Integrated Structure with a Radial Displacement Sensor and a Permanent Magnet Biased Radial Magnetic Bearing

    Directory of Open Access Journals (Sweden)

    Jinji Sun

    2014-01-01

    Full Text Available In this paper, a novel integrated structure is proposed in order to reduce the axial length of the high speed of a magnetically suspended motor (HSMSM to ensure the maximum speed, which combines radial displacement sensor probes and the permanent magnet biased radial magnetic bearing in HSMSM. The sensor probes are integrated in the magnetic bearing, and the sensor preamplifiers are placed in the control system of the HSMSM, separate from the sensor probes. The proposed integrated structure can save space in HSMSMs, improve the working frequency, reduce the influence of temperature on the sensor circuit, and improve the stability of HSMSMs.

  2. Association between internal carotid artery dissection and arterial tortuosity

    International Nuclear Information System (INIS)

    Saba, Luca; Piga, Mario; Argiolas, Giovanni Maria; Siotto, Paolo; Sumer, Suna; Wintermark, Max; Raz, Eytan; Sanfilippo, Roberto; Montisci, Roberto

    2015-01-01

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  3. Association between internal carotid artery dissection and arterial tortuosity

    Energy Technology Data Exchange (ETDEWEB)

    Saba, Luca; Piga, Mario [Azienda Ospedaliero Universitaria (A.O.U.), Department of Radiology, Monserrato, Cagliari (Italy); Argiolas, Giovanni Maria; Siotto, Paolo [Azienda Ospedaliero Brotzu (A.O.B.), Department of Radiology, di Cagliari (Italy); Sumer, Suna; Wintermark, Max [Neuroradiology Division, Neuroradiology, UVA Department of Radiology, Charlottesville, VA (United States); Raz, Eytan [New York University School of Medicine, Department of Radiology, New York, NY (United States); Sapienza University of Rome, Department of Neurology and Psychiatry, Rome (Italy); Sanfilippo, Roberto; Montisci, Roberto [Azienda Ospedaliero Universitaria (A.O.U.), Department of Vascular Surgery, di Cagliari (Italy)

    2014-10-18

    Carotid artery dissection is an important cause of ischemic stroke in all age groups, particularly in young patients. The purpose of this work was to assess whether there is an association between the presence of an internal carotid artery dissection (ICAD) and the arterial tortuosity. This study considered 124 patients (72 males and 52 females; median age 57 years) with CT/MR diagnosis of ICAD of the internal carotid artery were considered in this multi-centric retrospective study. The arterial tortuosity was evaluated and, when present, was categorized as elongation, kinking, or coiling. For each patient, both the right and left sides were considered for a total number of 248 arteries in order to have the same number of cases and controls. Fisher's exact test was applied to test the association between elongation, kinking, coiling, dissection, and the side affected by CAD. Fisher's exact test showed a statistically significant association between the ICAD and kinking (p = 0.0089) and coiling (p = 0.0251) whereas no statistically significant difference was found with arterial vessel elongation (p = 0.444). ICAD was more often seen on the left side compared to the right (p = 0.0001). These results were confirmed using both carotid arteries of the same patient as dependent parameter with p = 0.0012, 0.0129, and 0.3323 for kinking, coiling, and elongation, respectively. The presence of kinking and coiling is associated with ICAD. (orig.)

  4. Radial-piston pump for drive of test machines

    Science.gov (United States)

    Nizhegorodov, A. I.; Gavrilin, A. N.; Moyzes, B. B.; Cherkasov, A. I.; Zharkevich, O. M.; Zhetessova, G. S.; Savelyeva, N. A.

    2018-01-01

    The article reviews the development of radial-piston pump with phase control and alternating-flow mode for seismic-testing platforms and other test machines. The prospects for use of the developed device are proved. It is noted that the method of frequency modulation with the detection of the natural frequencies is easily realized by using the radial-piston pump. The prospects of further research are given proof.

  5. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  6. SpicyNodes Radial Map Engine

    Science.gov (United States)

    Douma, M.; Ligierko, G.; Angelov, I.

    2008-10-01

    The need for information has increased exponentially over the past decades. The current systems for constructing, exploring, classifying, organizing, and searching information face the growing challenge of enabling their users to operate efficiently and intuitively in knowledge-heavy environments. This paper presents SpicyNodes, an advanced user interface for difficult interaction contexts. It is based on an underlying structure known as a radial map, which allows users to manipulate and interact in a natural manner with entities called nodes. This technology overcomes certain limitations of existing solutions and solves the problem of browsing complex sets of linked information. SpicyNodes is also an organic system that projects users into a living space, stimulating exploratory behavior and fostering creative thought. Our interactive radial layout is used for educational purposes and has the potential for numerous other applications.

  7. Modelling and analysis of radial thermal stresses and temperature ...

    African Journals Online (AJOL)

    A theoretical investigation has been undertaken to study operating temperatures, heat fluxes and radial thermal stresses in the valves of a modern diesel engine with and without air-cavity. Temperatures, heat fluxes and radial thermal stresses were measured theoretically for both cases under all four thermal loading ...

  8. A novel integrated 4-DOF radial hybrid magnetic bearing for MSCMG

    Energy Technology Data Exchange (ETDEWEB)

    Jinji, Sun; Ziyan, Ju [School of Instrumentation Science & Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, Science and Technology on Inertial Laboratory, Beijing 100191 (China); Weitao, Han, E-mail: hanweitaotao@163.com [CRRC Qingdao Sifang CO., LTD, Qingdao 266111 (China); Gang, Liu [School of Instrumentation Science & Opto-electronics Engineering, Beijing University of Aeronautics and Astronautics, Science and Technology on Inertial Laboratory, Beijing 100191 (China)

    2017-01-01

    This paper proposes a novel integrated radial hybrid magnetic bearing (RHMB) for application with the small-sized magnetically suspended control moment gyroscope (MSCMG), which can control four degrees of freedom (4-DOFs), including two radial translational DOFs and two radial tilting DOFs, and provide the axial passive resilience. The configuration and working principle of the RHMB are introduced. Mathematical models of radial force, axial resilience and moment are established by using equivalent magnetic circuit method (EMCM), from which the radial force–radial displacement, radial force–current relationships are derived, as well as axial resilience–axial displacement, moment–tilting angle and moment–current. Finite element method (FEM) is also applied to analyze the performance and characteristics of the RHMB. The analysis results are in good agreement with that calculated by the EMCM, which is helpful in designing, optimizing and controlling the RHMB. The comparisons between the performances of the integrated 4-DOF RHMB and the traditional 4-DOF RHMB are made. The contrast results indicate that the proposed integrated 4-DOF RHMB possesses better performance compared to the traditional structure, such as copper loss, current stiffness, and tilting current stiffness. - Highlights: • An integrated 4-DOF RHMB is proposed for the small-sized MSCMG. • The 4-DOF RHMB has good linear force–displacement and force–current characteristics. • The RHMB has good linear moment–current and the moment–tilting angle characteristic.

  9. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  10. MRI of radial displacement of the meniscus in the knee

    International Nuclear Information System (INIS)

    Chen Jian; Lv Houshan; Lao Shan; Guan Zhenpeng; Hong Nan; Liang Hao

    2006-01-01

    Objective: To describe the phenomenon of radial displacement of the meniscus of the knees in the study population with MR imaging, and to establish MRI diagnostic criteria for radial displacement of the meniscus and displacement index. Methods: MR signs of radial displacement of the meniscus were evaluated retrospectively in 398 patients with knee symptoms who were examined with non- weight bearing MR images from Jan. 2000 to Feb. 2004. The patients younger than 18 years old, with joint effusion or serious arthropathy were excluded and 312 patients were eligible to be enrolled in this study. The criterion for radial displacement of the meniscus was defined as the location of the edge of meniscal body beyond the femoral and tibial outer border line. A displacement index, defined as the ratio of meniscal overhang to meniscal width, was used to quantify meniscal displacement. Results: The prevalence of radial displacement of the meniscus was 16.7% (52/312) and 13.9% (21/151) in right knee and 19.3% (31/161 )in left knee, respectively. There was no significant difference between left and right knee (χ 2 =1.60, P>0.05) and the ratio between medial and lateral meniscus was 7.8:1. The average displacement index was 0.54±0.24. The displacement indices were significant higher in older group (F=3.63, P<0.05). The incidence and indices of radial displacement of the meniscus for patients under or above 50 year older were 12.0%(17/142), 0.46±0.22 and 20.6% (35/170), 0.64±0.20, respectively. Difference was highly significant (t=0.84, P<0.01). Conclusion: It was concluded that radial displacement of the meniscus in knees was not a rare finding with MR imaging in patients with knee symptoms. The incidence increased in older age group. Further investigations were recommended to understand the etiology and clinical significance of the phenomenon of radial displacement of the meniscus. (authors)

  11. Cirurgia coronária com condutos arteriais múltiplos sem circulação extracorpórea Off-pump coronary artery bypass with multiple arterial conduits

    Directory of Open Access Journals (Sweden)

    Daniel Navia

    2005-03-01

    Full Text Available OBJETIVO: Analisar os resultados, em 30 dias, em pacientes submetidos de forma eletiva à revascularização arterial total do miocárdio sem circulação extracorpórea (CEC, e identificar preditores de morbimortalidade com esta estratégia cirúrgica. MÉTODO: Entre maio de 1999 e fevereiro de 2004, efetuaram-se 203 cirurgias de revascularização miocárdica (CRM com revascularização arterial total sem CEC, em pacientes com doença de múltiplos vasos (três vasos 81,7%, doença de um vaso excluída. Reportaram-se variáveis pré-operatórias e comorbidade: média de idade 63,9 ± 9,13 anos, homens 182 (89,5%, hipertensão 132 (65%, tabagismo 125 (61%, hipercolesterolemia 152 (74,8%, infarto agudo do miocárdio prévio (mais de 30 dias 73 (35%, disfunção ventricular moderada a grave 31 (15%, reoperação cinco (2,5%. A revascularização arterial total incluiu anastomoses em T e seqüenciais com artéria torácica interna esquerda (100%, torácica interna direita (56,6% e artéria radial (63%. O número total de anastomoses foi 576 (média de três pontes/paciente, todas efetuadas com estabilizadores mecânicos externos. Não form realizadas anastomoses proximais na aorta. Cirurgia com CEC foi realizada em três (1,5% pacientes. Noventa por cento dos pacientes foram extubados na sala de operações. Para a análise estatística, utilizou-se teste de regressão logística múltipla. RESULTADOS: A incidência de fibrilação atrial pós-operatória foi de 12,8% (26, insuficiência renal oligoanúrica 3% (seis, diálise 0,49% (um, infarto de miocárdio pós-operatório 1,47% (três, baixo débito cardíaco 4% (oito, reoperação por sangramento 1,47% (três, mediastinite 1,47% (três, acidente vascular cerebral 1,47% (três. A mortalidade intra-hospitalar foi de 2,45% (cinco. O único preditor independente de morbidade em 30 dias foi a idade (p=0,033; OR 1,04; IC 95%: 1-1,08. CONCLUSÃO: A cirurgia de revascularização miocárdica sem

  12. In vivo observation of the hypo-echoic "black hole" phenomenon in rat arterial bloodstream: a preliminary Study.

    Science.gov (United States)

    Nam, Kweon-Ho; Paeng, Dong-Guk

    2014-07-01

    The "black hole," a hypo-echoic hole at the center of the bloodstream surrounded by a hyper-echoic zone in cross-sectional views, has been observed in ultrasound backscattering measurements of blood with red blood cell aggregation in in vitro studies. We investigated whether the phenomenon occurs in the in vivo arterial bloodstream of rats using a high-frequency ultrasound imaging system. Longitudinal and cross-sectional ultrasound images of the rat common carotid artery (CCA) and abdominal aorta were obtained using a 40-MHz ultrasound system. A high-frame-rate retrospective imaging mode was employed to precisely examine the dynamic changes in blood echogenicity in the arteries. When the imaging was performed with non-invasive scanning, blood echogenicity was very low in the CCA as compared with the surrounding tissues, exhibiting no hypo-echoic zone at the center of the vessel. Invasive imaging of the CCA by incising the skin and subcutaneous tissues at the imaging area provided clearer and brighter blood echo images, showing the "black hole" phenomenon near the center of the vessel in longitudinal view. The "black hole" was also observed in the abdominal aorta under direct imaging after laparotomy. The aortic "black hole" was clearly observed in both longitudinal and cross-sectional views. Although the "black hole" was always observed near the center of the arteries during the diastolic phase, it dissipated or was off-center along with the asymmetric arterial wall dilation at systole. In conclusion, we report the first in vivo observation of the hypo-echoic "black hole" caused by the radial variation of red blood cell aggregation in arterial bloodstream. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  13. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  14. Vortex Whistle in Radial Intake

    National Research Council Canada - National Science Library

    Tse, Man-Chun

    2004-01-01

    In a radial-to-axial intake with inlet guide vanes (IGV) at the entry, a strong flow circulation Gamma can be generated from the tangential flow components created by the IGVs when their setting exceed about halfclosing (approx. 45 deg...

  15. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  16. Radial optimization of a BWR fuel cell using genetic algorithms; Optimizacion radial de una celda de combustible BWR usando algoritmos geneticos

    Energy Technology Data Exchange (ETDEWEB)

    Martin del Campo M, C.; Carmona H, R.; Oropeza C, I.P. [UNAM, Paseo Cuauhnahuac 8532, 62550 Jiutepec, Morelos (Mexico)]. e-mail: cmcm@fi-b.unam.mx

    2006-07-01

    The development of the application of the Genetic Algorithms (GA) to the optimization of the radial distribution of enrichment in a cell of fuel of a BWR (Boiling Water Reactor) is presented. The optimization process it was ties to the HELIOS simulator, which is a transport code of neutron simulation of fuel cells that has been validated for the calculation of nuclear banks for BWRs. With heterogeneous radial designs can improve the radial distribution of the power, for what the radial design of fuel has a strong influence in the global design of fuel recharges. The optimum radial distribution of fuel bars is looked for with different enrichments of U{sup 235} and contents of consumable poison. For it is necessary to define the representation of the solution, the objective function and the implementation of the specific optimization process to the solution of the problem. The optimization process it was coded in 'C' language, it was automated the creation of the entrances to the simulator, the execution of the simulator and the extraction, in the exit of the simulator, of the parameters that intervene in the objective function. The objective function includes four parameters: average enrichment of the cell, average gadolinia concentration of the cell, peak factor of radial power and k-infinite multiplication factor. To be able to calculate the parameters that intervene in the objective function, the one evaluation process of GA was ties to the HELIOS code executed in a Compaq Alpha workstation. It was applied to the design of a fuel cell of 10 x 10 that it can be employee in the fuel assemble designs that are used at the moment in the Laguna Verde Nucleo electric Central. Its were considered 10 different fuel compositions which four contain gadolinia. Three heuristic rules that consist in prohibiting the placement of bars with gadolinia in the ends of the cell, to place the compositions with the smallest enrichment in the corners of the cell and to fix

  17. The Features of Extrahepatic Collateral Arteries Related to Hepatic Artery Occlusion and Benefits in the Trans arterial Management of Liver Tumors

    International Nuclear Information System (INIS)

    Yang, L.; Zhang, X.M.; Ren, Y.J.; Miao, N.D.; Huang, X.H.; Dong, G.L.

    2013-01-01

    To investigate the extrahepatic collateral arteries related to hepatic artery occlusion (HAO) and to determine its benefits in the trans arterial management of liver tumors. Methods and Findings. Eleven patients (7 hepatocellular carcinomas, 3 liver metastases, and 1 with hemangioma) with HAO confirmed with digital subtraction angiography (DSA) were admitted to our hospital. Of the 11 patients, 7 were men and 4 were women, with an average age of 41.5 ± 15.5 years (range: 29 to 70 years). DSA was performed to evaluate the collateral routes to the liver. In the 11 patients with HAO, DSA showed complete occlusion of the common hepatic artery in 9 patients and the proper hepatic artery (PHA) in 2 patients. Extrahepatic collateral arteries supplying the liver were readily evident. The collateral arteries originated from the superior mesenteric artery (SMA) in 8 patients, from the gastroduodenal artery in 2 patients, and from the left gastric artery (LGA) in 1 patient. Transcatheter treatment was successfully performed via the collateral artery in all patients except the one who had hemangioma. Conclusions. DSA is an effective method for detecting collateral circulation related to HAO and may provide information to guide transcatheter management decisions.

  18. Rotary and radial forcing effects on center-of-mass locomotion dynamics

    International Nuclear Information System (INIS)

    Shen, Z H; Larson, P L; Seipel, J E

    2014-01-01

    Rotary and radial forcing are two common actuation methods for legged robots. However, these two orthogonal methods of center-of-mass (CoM) forcing have not been compared as potentially alternative strategies of actuation. In this paper, we compare the CoM stability and energetics of running with rotary and radial actuation through the simulation of two models: the rotary-forced spring-loaded inverted pendulum (rotary-forced-SLIP), and the radially-forced-SLIP. We model both radial and rotary actuation in the simplest way, applying them as a constant force during the stance portion of the gait. A simple application of constant rotary forcing throughout stance is capable of producing fully-asymptotically stable motion; however, a similarly constant application of radial forcing throughout the stance is not capable of producing stable solutions. We then allow both the applied rotary and radial forcing functions to turn on or off based on the occurrence of the mid-stance event, which breaks the symmetry of actuation during stance towards a net forward propulsion. We find that both a rotary force applied in the first half of stance and a radial force applied in the second half of stance, are capable of stabilizing running. Interestingly, these two forcing methods improve the motion stability in different ways. Rotary forcing first reduces then greatly increases the size of the stable parameter region when gradually increased. Radial forcing expands the stable parameter region, but only in a moderate way. Also, it is found that parameter region stabilized by rotary and radial forcing are largely complementary. Overall, rotary forcing can better stabilize running for both constant and event-based forcing functions that were attempted. This indicates that rotary forcing has an inherent capability of stabilizing running, even when minimal time-or-event-or-state feedback is present. Radial forcing, however, tends to be more energy efficient when compared to rotary forcing

  19. Redundant Vasodilator Pathways Underlying Radial Artery Flow-Mediated Dilation Are Preserved in Healthy Aging

    Directory of Open Access Journals (Sweden)

    Kevin D. Ballard

    2014-01-01

    Full Text Available Background. Blocking nitric oxide (NO and vasodilator prostanoids (PN does not consistently reduce flow-mediated dilation (FMD in young adults. The impact of aging on the contribution of NO and PG to FMD is unknown. Methods. FMD was measured in older adults (n=10, 65±3 y after arterial infusion of saline, N(G-monomethyl-L-arginine (L-NMMA, and ketorolac + L-NMMA. Data were compared to published data in young adults. Results. L-NMMA reduced FMD in older adults (8.9±3.6 to 5.9±3.7% although this was not statistically significant (P=0.08 and did not differ (P=0.74 from the reduction observed in young adults (10.0±3.8 to 7.6±4.7%; P=0.03. Blocking PN did not affect FMD in young or older adults. In older adults, L-NMMA reduced (n=6; range = 36–123% decrease, augmented (n=3; 10–122% increase, or did not change FMD (n=1; 0.4% increase. After PN blockade, FMD responses were reduced (n=2, augmented (n=6, or unaffected (n=1. Conclusions. NO or PN blockade did not consistently reduce FMD in healthy older adults, suggesting the existence of redundant vasodilator phenotypes as observed previously in young adults.

  20. Use of a pressure sensing sheath: comparison with standard means of blood pressure monitoring in catheterization procedures.

    Science.gov (United States)

    Purdy, Phillip D; South, Charles; Klucznik, Richard P; Liu, Kenneth C; Novakovic, Robin L; Puri, Ajit S; Pride, G Lee; Aagaard-Kienitz, Beverly; Ray, Abishek; Elliott, Alan C

    2017-08-01

    Monitoring of blood pressure (BP) during procedures is variable, depending on multiple factors. Common methods include sphygmomanometer (BP cuff), separate radial artery catheterization, and side port monitoring of an indwelling sheath. Each means of monitoring has disadvantages, including time consumption, added risk, and signal dampening due to multiple factors. We sought an alternative approach to monitoring during procedures in the catheterization laboratory. A new technology involving a 330 µm fiberoptic sensor embedded in the wall of a sheath structure was tested against both radial artery catheter and sphygmomanometer readings obtained simultaneous with readings recorded from the pressure sensing system (PSS). Correlations and Bland-Altman analysis were used to determine whether use of the PSS could substitute for these standard techniques. The results indicated highly significant correlations in systolic, diastolic, and mean arterial pressures (MAP) when compared against radial artery catheterization (p<0.0001), and MAP means differed by <4%. Bland-Altman analysis of the data suggested that the sheath measurements can replace a separate radial artery catheter. While less striking, significant correlations were seen when PSS readings were compared against BP cuff readings. The PSS has competitive functionality to that seen with a dedicated radial artery catheter for BP monitoring and is available immediately on sheath insertion without the added risk of radial catheterization. The sensor is structurally separated from the primary sheath lumen and readings are unaffected by device introduction through the primary lumen. Time delays and potential complications from radial artery catheterization are avoided. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  1. The First Experience of Triple Nerve Transfer in Proximal Radial Nerve Palsy.

    Science.gov (United States)

    Emamhadi, Mohammadreza; Andalib, Sasan

    2018-01-01

    Injury to distal portion of posterior cord of brachial plexus leads to palsy of radial and axillary nerves. Symptoms are usually motor deficits of the deltoid muscle; triceps brachii muscle; and extensor muscles of the wrist, thumb, and fingers. Tendon transfers, nerve grafts, and nerve transfers are options for surgical treatment of proximal radial nerve palsy to restore some motor functions. Tendon transfer is painful, requires a long immobilization, and decreases donor muscle strength; nevertheless, nerve transfer produces promising outcomes. We present a patient with proximal radial nerve palsy following a blunt injury undergoing triple nerve transfer. The patient was involved in a motorcycle accident with complete palsy of the radial and axillary nerves. After 6 months, on admission, he showed spontaneous recovery of axillary nerve palsy, but radial nerve palsy remained. We performed triple nerve transfer, fascicle of ulnar nerve to long head of the triceps branch of radial nerve, flexor digitorum superficialis branch of median nerve to extensor carpi radialis brevis branch of radial nerve, and flexor carpi radialis branch of median nerve to posterior interosseous nerve, for restoration of elbow, wrist, and finger extensions, respectively. Our experience confirmed functional elbow, wrist, and finger extensions in the patient. Triple nerve transfer restores functions of the upper limb in patients with debilitating radial nerve palsy after blunt injuries. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Comparison of pulseoximetry oxygen saturation and arterial oxygen saturation in open heart intensive care unit

    Directory of Open Access Journals (Sweden)

    Alireza Mahoori

    2013-08-01

    Full Text Available Background: Pulseoximetry is widely used in the critical care setting, currently used to guide therapeutic interventions. Few studies have evaluated the accuracy of SPO2 (puls-eoximetry oxygen saturation in intensive care unit after cardiac surgery. Our objective was to compare pulseoximetry with arterial oxygen saturation (SaO2 during clinical routine in such patients, and to examine the effect of mild acidosis on this relationship.Methods: In an observational prospective study 80 patients were evaluated in intensive care unit after cardiac surgery. SPO2 was recorded and compared with SaO2 obtained by blood gas analysis. One or serial arterial blood gas analyses (ABGs were performed via a radial artery line while a reliable pulseoximeter signal was present. One hundred thirty seven samples were collected and for each blood gas analyses, SaO2 and SPO2 we recorded.Results: O2 saturation as a marker of peripheral perfusion was measured by Pulseoxim-etry (SPO2. The mean difference between arterial oxygen saturation and pulseoximetry oxygen saturation was 0.12%±1.6%. A total of 137 paired readings demonstrated good correlation (r=0.754; P<0.0001 between changes in SPO2 and those in SaO2 in samples with normal hemoglobin. Also in forty seven samples with mild acidosis, paired readings demonstrated good correlation (r=0.799; P<0.0001 and the mean difference between SaO2 and SPO2 was 0.05%±1.5%.Conclusion: Data showed that in patients with stable hemodynamic and good signal quality, changes in pulseoximetry oxygen saturation reliably predict equivalent changes in arterial oxygen saturation. Mild acidosis doesn’t alter the relation between SPO2 and SaO2 to any clinically important extent. In conclusion, the pulse oximeter is useful to monitor oxygen saturation in patients with stable hemodynamic.

  3. Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension.

    Science.gov (United States)

    Frydrychowicz, A; Roldan-Alzate, A; Winslow, E; Consigny, D; Campo, C A; Motosugi, U; Johnson, K M; Wieben, O; Reeder, S B

    2017-12-01

    Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R 2  = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. • Radial 4D Flow-MRI in the abdomen was successfully compared to perivascular ultrasound. • Inter- and intra-reader testing demonstrated excellent reproducibility of upper abdominal 4D Flow-MRI. • A porcine model of acute pre-hepatic portal hypertension was successfully introduced. • 4D Flow-MRI successfully monitored acute changes in a model of portal hypertension.

  4. Development of a Radial Deconsolidation Method

    Energy Technology Data Exchange (ETDEWEB)

    Helmreich, Grant W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Montgomery, Fred C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hunn, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    A series of experiments have been initiated to determine the retention or mobility of fission products* in AGR fuel compacts [Petti, et al. 2010]. This information is needed to refine fission product transport models. The AGR-3/4 irradiation test involved half-inch-long compacts that each contained twenty designed-to-fail (DTF) particles, with 20-μm thick carbon-coated kernels whose coatings were deliberately fabricated such that they would crack under irradiation, providing a known source of post-irradiation isotopes. The DTF particles in these compacts were axially distributed along the compact centerline so that the diffusion of fission products released from the DTF kernels would be radially symmetric [Hunn, et al. 2012; Hunn et al. 2011; Kercher, et al. 2011; Hunn, et al. 2007]. Compacts containing DTF particles were irradiated at Idaho National Laboratory (INL) at the Advanced Test Reactor (ATR) [Collin, 2015]. Analysis of the diffusion of these various post-irradiation isotopes through the compact requires a method to radially deconsolidate the compacts so that nested-annular volumes may be analyzed for post-irradiation isotope inventory in the compact matrix, TRISO outer pyrolytic carbon (OPyC), and DTF kernels. An effective radial deconsolidation method and apparatus appropriate to this application has been developed and parametrically characterized.

  5. [Efferent innervation of the arteries of human leptomeninx in arterial hypertension].

    Science.gov (United States)

    Chertok, V M; Kotsiuba, A E; Babich, E V

    2009-01-01

    Structure of the efferent nerve plexuses (adrenergic, acetylcholinestherase- and cholinacetyltranspherase-positive, NO-dependent), was studied in the arteries of human leptomeninx with different diameters. Material was obtained from the corpses of the healthy people and of the patients with initial stages of arterial hypertension (AH). It was shown that the concentrations of cholinergic and adrenergic nerve fibers and varicosities in axon terminal part, innervating the arteries with the diameters ranging from 450 till 100 microm, were not significantly different. In these arteries, NO-ergic plexuses were also detected. In patients with AH, regardless the arterial diameters, the significant increase (up to 15-20%) of adrenergic nerve fiber and varicosity concentrations was found. The changes in cholinergic nerve fiber concentration were found to depend on the vessel diameter: the significant decrease of these parameter was observed only in arteries with the diameter of 100-200 microm. No significant changes in nerve plexus concentration was noticed in the arteries with greater or smaller diameter. In NO-ergic neural conductors, the enzyme activity decreased only in the large arteries, and remained almost unchanged in the small vascular branches. The changes in the vasomotor innervation described in AH, are interpreted as a vasomotor innervation dysfunction of the leptomeninx arteries that may result in the hemodynamic disturbances.

  6. A visual study of radial inward choked flow of liquid nitrogen.

    Science.gov (United States)

    Hendricks, R. C.; Simoneau, R. J.; Hsu, Y. Y.

    1973-01-01

    Data and high speed movies were acquired on pressurized subcooled liquid nitrogen flowing radially inward through a 0.0076 cm gap. The stagnation pressure ranged from 0.7 to 4 MN/sq m. Steady radial inward choked flow appears equivalent to steady choked flow through axisymmetric nozzles. Transient choked flows through the radial gap are not uniform and the discharge pattern appears as nonuniform impinging jets. The critical mass flow rate data for the transient case appear different from those for the steady case. On the mass flow rate vs pressure map, the slope and separation of the isotherms appear to be less for transient than for steady radial choked flow.

  7. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Joon Ho; Kim, Man Deuk, E-mail: mdkim@yuhs.ac; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun [Yonsei University College of Medicine, Department of Radiology, Research Institute of Radiological Science, Severance Hospital (Korea, Republic of)

    2013-02-15

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  8. Aberrant Ovarian Collateral Originating from External Iliac Artery During Uterine Artery Embolization

    International Nuclear Information System (INIS)

    Kwon, Joon Ho; Kim, Man Deuk; Lee, Kwang-hun; Lee, Myungsu; Lee, Mu Sook; Won, Jong Yun; Park, Sung Il; Lee, Do Yun

    2013-01-01

    We report a case of a 35-year-old woman who underwent uterine artery embolization (UAE) for symptomatic multiple uterine fibroids with collateral aberrant right ovarian artery that originated from the right external iliac artery. We believe that this is the first reported case in the literature of this collateral uterine flow by the right ovarian artery originated from the right external iliac artery. We briefly present the details of the case and review the literature on variations of ovarian artery origin that might be encountered during UAE.

  9. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  10. Feeding Arteries of Primary Tongue Cancers on Intra-arterial Infusion Chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kamitani, Takeshi, E-mail: kamitani@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences (Japan); Kawanami, Satoshi, E-mail: kawanami-01@mac.com [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences (Japan); Asayama, Yoshiki, E-mail: asayama@radiol.med.kyushu-u.ac.jp; Matsuo, Yoshio, E-mail: yymatsuo@radiol.med.kyushu-u.ac.jp; Yonezawa, Masato, E-mail: ymasato@radiol.med.kyushu-u.ac.jp; Yamasaki, Yuzo, E-mail: yyama@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences (Japan); Nagao, Michinobu, E-mail: minagao@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Molecular Imaging and Diagnosis, Graduate School of Medical Sciences (Japan); Yamanouchi, Torahiko, E-mail: tora0228@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences (Japan); Yabuuchi, Hidetake, E-mail: h-yabu@med.kyushu-u.ac.jp [Kyushu University, Department of Health Sciences, Graduate School of Medical Sciences (Japan); Nakamura, Katsumasa, E-mail: nakam@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences (Japan); Nakashima, Torahiko, E-mail: nakatora@qent.med.kyushu-u.ac.jp [Kyushu University, Department of Otorhinolaryngology, Graduate School of Medical Sciences (Japan); Honda, Hiroshi, E-mail: honda@radiol.med.kyushu-u.ac.jp [Kyushu University, Department of Clinical Radiology, Graduate School of Medical Sciences (Japan)

    2016-02-15

    PurposeTo evaluate the frequency and the predictive factor of each feeding artery on intra-arterial infusion chemotherapy (IAIC) in primary tongue cancer.Materials and MethodsWe retrospectively evaluated 20 patients who received IAIC for primary tongue cancer. The main and accompanying feeding arteries were identified on super-selective angiography of the branches of the external carotid artery. Tumor diameter, and extension to the contralateral side, tongue extrinsic muscles (TEMs), and lateral mesopharyngeal wall were determined based on magnetic resonance imaging or computed tomography findings.ResultsThe main feeding artery was the ipsilateral lingual artery (LA) in 15 of the 20 examined tumors and the contralateral LA in the other 5. Ten cancers had only one feeding artery, and multiple feeding arteries were detected in the remaining 10. Tumors >4 cm (n = 9), those with extension to the contralateral side (n = 13), and those with extension to TEMs (n = 15) were supplied by significantly larger numbers of feeding arteries compared to tumors without these features (P = 0.01, 0.049, and 0.02, respectively). The frequency of feeding from the contralateral LA was 64 % (9/14) and 17 % (1/6) in tumors with and without extension to the contralateral side, respectively. Feeding from a facial artery (FA) was not detected in tumors ≤4 cm, while 5 of the 9 (56 %) tumors >4 cm were supplied by a FA (P = 0.01).ConclusionA careful search for feeding arteries is required, especially in large tumors with extension to the contralateral side or to TEMs.

  11. Feeding Arteries of Primary Tongue Cancers on Intra-arterial Infusion Chemotherapy.

    Science.gov (United States)

    Kamitani, Takeshi; Kawanami, Satoshi; Asayama, Yoshiki; Matsuo, Yoshio; Yonezawa, Masato; Yamasaki, Yuzo; Nagao, Michinobu; Yamanouchi, Torahiko; Yabuuchi, Hidetake; Nakamura, Katsumasa; Nakashima, Torahiko; Honda, Hiroshi

    2016-02-01

    To evaluate the frequency and the predictive factor of each feeding artery on intra-arterial infusion chemotherapy (IAIC) in primary tongue cancer. We retrospectively evaluated 20 patients who received IAIC for primary tongue cancer. The main and accompanying feeding arteries were identified on super-selective angiography of the branches of the external carotid artery. Tumor diameter, and extension to the contralateral side, tongue extrinsic muscles (TEMs), and lateral mesopharyngeal wall were determined based on magnetic resonance imaging or computed tomography findings. The main feeding artery was the ipsilateral lingual artery (LA) in 15 of the 20 examined tumors and the contralateral LA in the other 5. Ten cancers had only one feeding artery, and multiple feeding arteries were detected in the remaining 10. Tumors >4 cm (n = 9), those with extension to the contralateral side (n = 13), and those with extension to TEMs (n = 15) were supplied by significantly larger numbers of feeding arteries compared to tumors without these features (P = 0.01, 0.049, and 0.02, respectively). The frequency of feeding from the contralateral LA was 64 % (9/14) and 17 % (1/6) in tumors with and without extension to the contralateral side, respectively. Feeding from a facial artery (FA) was not detected in tumors ≤4 cm, while 5 of the 9 (56 %) tumors >4 cm were supplied by a FA (P = 0.01). A careful search for feeding arteries is required, especially in large tumors with extension to the contralateral side or to TEMs.

  12. Mejoramiento de imágenes usando funciones de base radial Images improvement using radial basis functions

    Directory of Open Access Journals (Sweden)

    Jaime Alberto Echeverri Arias

    2009-07-01

    Full Text Available La eliminación del ruido impulsivo es un problema clásico del procesado no lineal para el mejoramiento de imágenes y las funciones de base radial de soporte global son útiles para enfrentarlo. Este trabajo presenta una técnica de interpolación que disminuye eficientemente el ruido impulsivo en imágenes, mediante el uso de interpolante obtenido por funciones de base radial en el marco de la investigación enfocada en el desarrollo de un Sistema de recuperación de imágenes de recursos acuáticos amazónicos. Esta técnica primero etiqueta los píxeles de la imagen que son ruidosos y, mediante la interpolación, genera un valor de reconstrucción de dicho píxel usando sus vecinos. Los resultados obtenidos son comparables y muchas veces mejores que otras técnicas ya publicadas y reconocidas. Según el análisis de resultados, se puede aplicar a imágenes con altas tasas de ruido, manteniendo un bajo error de reconstrucción de los píxeles "ruidosos", así como la calidad visual.Global support radial base functions are effective in eliminating impulsive noise in non-linear processing. This paper introduces an interpolation technique which efficiently reduces image impulsive noise by means of an interpolant obtained through radial base functions. These functions have been used in a research project designed to develop a system for the recovery of images of Amazonian aquatic resources. This technique starts with the tagging by interpolation of noisy image pixels. Thus, a value of reconstruction for the noisy pixels is generated using neighboring pixels. The results obtained with this technique have proved comparable and often better than those obtained with previously known techniques. According to results analysis, this technique can be successfully applied on images with high noise levels. The results are low error in noisy pixel reconstruction and better visual quality.

  13. Sirenomelia with radial dysplasia.

    Science.gov (United States)

    Kulkarni, M L; Abdul Manaf, K M; Prasannakumar, D G; Kulkarni, Preethi M

    2004-05-01

    Sirenomelia is a rare anomaly usually associated with other multiple malformations. In this communication the authors report a case of sirenomelia associated with multiple malformations, which include radial hypoplasia also. Though several theories have been proposed regarding the etiology of multiple malformation syndromes in the past, the recent theory of primary developmental defect during blastogenesis holds good in this case.

  14. Comparison of Deterministic and Probabilistic Radial Distribution Systems Load Flow

    Science.gov (United States)

    Gupta, Atma Ram; Kumar, Ashwani

    2017-12-01

    Distribution system network today is facing the challenge of meeting increased load demands from the industrial, commercial and residential sectors. The pattern of load is highly dependent on consumer behavior and temporal factors such as season of the year, day of the week or time of the day. For deterministic radial distribution load flow studies load is taken as constant. But, load varies continually with a high degree of uncertainty. So, there is a need to model probable realistic load. Monte-Carlo Simulation is used to model the probable realistic load by generating random values of active and reactive power load from the mean and standard deviation of the load and for solving a Deterministic Radial Load Flow with these values. The probabilistic solution is reconstructed from deterministic data obtained for each simulation. The main contribution of the work is: Finding impact of probable realistic ZIP load modeling on balanced radial distribution load flow. Finding impact of probable realistic ZIP load modeling on unbalanced radial distribution load flow. Compare the voltage profile and losses with probable realistic ZIP load modeling for balanced and unbalanced radial distribution load flow.

  15. Introducing radiality constraints in capacitated location-routing problems

    Directory of Open Access Journals (Sweden)

    Eliana Mirledy Toro Ocampo

    2017-03-01

    Full Text Available In this paper, we introduce a unified mathematical formulation for the Capacitated Vehicle Routing Problem (CVRP and for the Capacitated Location Routing Problem (CLRP, adopting radiality constraints in order to guarantee valid routes and eliminate subtours. This idea is inspired by formulations already employed in electric power distribution networks, which requires a radial topology in its operation. The results show that the proposed formulation greatly improves the convergence of the solver.

  16. Analysis on Coupled Vibration of a Radially Polarized Piezoelectric Cylindrical Transducer

    Directory of Open Access Journals (Sweden)

    Jie Xu

    2017-12-01

    Full Text Available Coupled vibration of a radially polarized piezoelectric cylindrical transducer is analyzed with the mechanical coupling coefficient method. The method has been utilized to analyze the metal cylindrical transducer and the axially polarized piezoelectric cylindrical transducer. In this method, the mechanical coupling coefficient is introduced and defined as the stress ratio in different directions. Coupled vibration of the cylindrical transducer is regarded as the interaction of the plane radial vibration of a ring and the longitudinal vibration of a tube. For the radially polarized piezoelectric cylindrical transducer, the radial and longitudinal electric admittances as functions of mechanical coupling coefficients and angular frequencies are derived, respectively. The resonance frequency equations are obtained. The dependence of resonance frequency and mechanical coupling coefficient on aspect ratio is studied. Vibrational distributions on the surfaces of the cylindrical transducer are presented with experimental measurement. On the support of experiments, this work is verified and provides a theoretical foundation for the analysis and design of the radially polarized piezoelectric cylindrical transducer.

  17. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    International Nuclear Information System (INIS)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun

    1995-01-01

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method

  18. Recanalization of superficial femoral artery by retrograde approach via popliteal artery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Kyu; Kim, Hyung Kil; Yun, Ung; Seo, Jeong Jin; Kang, Heoung Keun [Chonnam University Medical School, Kwangju (Korea, Republic of)

    1995-09-15

    To recanalize the occlusive lesion of superficial femoral artery at origin site by retrograde approach via popliteal artery. 15 patients, who were poor surgical candidates due to coronary artery disease and who had severe occlusive lesion of superficial femoral artery close to its origin with good distal runoffs to popliteal artery, were selected. Patients were all men and range of age were from 53 years to 66 years (mean age: 63 years). Range of lesion length were from 15 cm to 30 cm (mean length: 22.4 cm). Localization of popliteal artery was done with Doppler stethoscope or 'road-map' DSA. The method of recanalization were transluminal endarterectomy catheter (TEC), TEC and angioplasty, thrombolysoangioplasty (TLA). Retrograde puncture of popliteal artery was done in 15 patients successfully. TEC and PTA was performed in 9 patients, TEC only in 2 patients, and TLA and PTA in 2 patients. During the follow-up period of 5 months to 2 years reocclusion did not occur in 10 patients except for 1 patient with poor cardiac output in whom it occurred 1 day later. Remained 4 patients were lost in follow up. Any neurologic or vascular complication did not occur. Retrograde approach of superficial femoral artery via popliteal artery in patients with difficult vascular intervention by common method provides a useful, alternative recanalization method.

  19. Effects of acute aerobic exercise on arterial stiffness and cerebrovascular pulsatility in adults with and without hypertension.

    Science.gov (United States)

    Lefferts, Wesley K; DeBlois, Jacob P; Receno, Candace N; Barreira, Tiago V; Brutsaert, Tom D; Carhart, Robert L; Heffernan, Kevin S

    2018-04-19

    Stiffer central arteries, as seen in hypertension (HTN), foster transmission of pulsatile hemodynamics into fragile cerebral vessels. Aerobic exercise is recommended for adults with HTN, but its effects on arterial stiffness and pulsatility in this group are unclear. This study sought to investigate the effect of acute aerobic exercise on arterial stiffness and cerebrovascular pulsatility in 30 adults with treated HTN and 30 age, sex, and BMI-matched adults without HTN (56 ± 6 years, BMI 28.2 ± 2.9 kg/m; 28 women). Patients underwent hemodynamic measures before/after 30-min cycling (≈55% peak oxygen consumption). Aortic stiffness was measured using carotid-femoral pulse wave velocity, and carotid artery stiffness was assessed with β-stiffness via ultrasound. Aortic/carotid pulse pressure (aortic via radial generalized transfer function) was measured by tonometry and calibrated to brachial mean pressure and diastolic pressure. Carotid/middle cerebral artery (MCA) blood velocity pulsatility indices were measured using Doppler. Carotid wave intensity analysis was used to derive forward wave intensity (W1). Exercise impacted hemodynamics similarly in HTN compared to no-HTN. Carotid-femoral pulse wave velocity, MCA pulsatility index, carotid pulsatility index, and W1 increased similarly after exercise in both groups (P < 0.05). Carotid pulse pressure and β-stiffness were unaltered after exercise. Postexercise changes in W1 were positively associated with carotid pulsatility index, which was further associated with MCA pulsatility index. These data suggest adults with treated HTN experience similar increases in aortic stiffness and cerebrovascular hemodynamic pulsatility during early recovery from acute aerobic exercise as their counterparts without HTN.

  20. Turbulence in tokamak plasmas. Effect of a radial electric field shear; Turbulence dans les plasmas de tokamaks. Effet d`un cisaillement de champ electrique radial

    Energy Technology Data Exchange (ETDEWEB)

    Payan, J

    1994-05-01

    After a review of turbulence and transport phenomena in tokamak plasmas and the radial electric field shear effect in various tokamaks, experimental measurements obtained at Tore Supra by the means of the ALTAIR plasma diagnostic technique, are presented. Electronic drift waves destabilization mechanisms, which are the main features that could describe the experimentally observed microturbulence, are then examined. The effect of a radial electric field shear on electronic drift waves is then introduced, and results with ohmic heating are studied together with relations between turbulence and transport. The possible existence of ionic waves is rejected, and a spectral frequency modelization is presented, based on the existence of an electric field sheared radial profile. The position of the inversion point of this field is calculated for different values of the mean density and the plasma current, and the modelization is applied to the TEXT tokamak. The radial electric field at Tore Supra is then estimated. The effect of the ergodic divertor on turbulence and abnormal transport is then described and the density fluctuation radial profile in presence of the ergodic divertor is modelled. 80 figs., 120 refs.

  1. Condition of damping of anomalous radial transport, determined by ordered convective electron dynamics

    International Nuclear Information System (INIS)

    Maslov, V.I.; Barchuk, S.V.; Lapshin, V.I.; Volkov, E.D.; Melentsov, Yu.V.

    2006-01-01

    It is shown, that at development of instability due to a radial gradient of density in the crossed electric and magnetic fields in nuclear fusion installations ordering convective cells can be excited. It provides anomalous particle transport. The spatial structures of these convective cells have been constructed. The radial dimensions of these convective cells depend on their amplitudes and on a radial gradient of density. The convective-diffusion equation for radial dynamics of the electrons has been derived. At the certain value of the universal controlling parameter, the convective cell excitation and the anomalous radial transport are suppressed. (author)

  2. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  3. Plasma Signatures of Radial Field Power Dropouts

    International Nuclear Information System (INIS)

    Lucek, E.A.; Horbury, T.S.; Balogh, A.; McComas, D.J.

    1998-01-01

    A class of small scale structures, with a near-radial magnetic field and a drop in magnetic field fluctuation power, have recently been identified in the polar solar wind. An earlier study of 24 events, each lasting for 6 hours or more, identified no clear plasma signature. In an extension of that work, radial intervals lasting for 4 hours or more (89 in total), have been used to search for a statistically significant plasma signature. It was found that, despite considerable variations between intervals, there was a small but significant drop, on average, in plasma temperature, density and β during these events

  4. Reble, a radially converging electron beam accelerator

    International Nuclear Information System (INIS)

    Ramirez, J.J.; Prestwich, K.R.

    1976-01-01

    The Reble accelerator at Sandia Laboratories is described. This accelerator was developed to provide an experimental source for studying the relevant diode physics, beam propagation, beam energy deposition in a gas using a radially converging e-beam. The nominal parameters for Reble are 1 MV, 200 kA, 20 ns e-beam pulse. The anode and cathode are concentric cylinders with the anode as the inner cylinder. The radial beam can be propagated through the thin foil anode into the laser gas volume. The design and performance of the various components of the accelerator are presented

  5. Basilar artery angulation and vertigo due to the hemodynamic effect of dominant vertebral artery.

    Science.gov (United States)

    Cosar, Murat; Yaman, Mehmet; Eser, Olcay; Songur, Ahmet; Ozen, Oguz A

    2008-01-01

    Vertebral arteries form the basilar artery at the pontobulbar junction. The vertebral artery may have dominancy in one of them. The branches of basilar arteries supply blood for the vestibular nuclei and its connections. Vertigo is seen generally in the upper middle aged patients. Vertigo can be observed in dolichoectasia of basilar artery such as angulation and elongation, because of the diminished blood supply and changed hemodynamic factors of vestibular nuclei and its connections. We hypothesized that angulation or elongation of basilar artery can be estimated according to the unilateral vertebral artery dominant hypertensive patients. The basilar artery can angulate from the dominant side of vertebral artery to the recessive side. These angulation and elongation can effect the hemodynamic factors in absence of growing collateral arteries. So, the vertigo attacks may occur in these patients.

  6. Deep learning-based artificial vision for grasp classification in myoelectric hands

    Science.gov (United States)

    Ghazaei, Ghazal; Alameer, Ali; Degenaar, Patrick; Morgan, Graham; Nazarpour, Kianoush

    2017-06-01

    Objective. Computer vision-based assistive technology solutions can revolutionise the quality of care for people with sensorimotor disorders. The goal of this work was to enable trans-radial amputees to use a simple, yet efficient, computer vision system to grasp and move common household objects with a two-channel myoelectric prosthetic hand. Approach. We developed a deep learning-based artificial vision system to augment the grasp functionality of a commercial prosthesis. Our main conceptual novelty is that we classify objects with regards to the grasp pattern without explicitly identifying them or measuring their dimensions. A convolutional neural network (CNN) structure was trained with images of over 500 graspable objects. For each object, 72 images, at {{5}\\circ} intervals, were available. Objects were categorised into four grasp classes, namely: pinch, tripod, palmar wrist neutral and palmar wrist pronated. The CNN setting was first tuned and tested offline and then in realtime with objects or object views that were not included in the training set. Main results. The classification accuracy in the offline tests reached 85 % for the seen and 75 % for the novel objects; reflecting the generalisability of grasp classification. We then implemented the proposed framework in realtime on a standard laptop computer and achieved an overall score of 84 % in classifying a set of novel as well as seen but randomly-rotated objects. Finally, the system was tested with two trans-radial amputee volunteers controlling an i-limb UltraTM prosthetic hand and a motion controlTM prosthetic wrist; augmented with a webcam. After training, subjects successfully picked up and moved the target objects with an overall success of up to 88 % . In addition, we show that with training, subjects’ performance improved in terms of time required to accomplish a block of 24 trials despite a decreasing level of visual feedback. Significance. The proposed design constitutes a substantial

  7. Endovascular rescue from arterial rupture and thrombosis during middle cerebral artery stenting

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, J.Y.; Chung, Y.S. [Department of Neurosurgery, College of Medicine, Pundang CHA Hospital, 351 Yatap-ding, Pundang-gu, 463-712, Sungnam (Korea); Lee, B.H. [Department of Interventional Neuroradiology, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea); Kim, O.J. [Department of Emergency Medicine, College of Medicine, Pundang CHA Hospital, 351 Yatap-dong, Pundang-gu, 463-712, Sungnam (Korea)

    2003-08-01

    Intravascular stents are being used with increasing frequency in interventional neuroradiology. Iatrogenic arterial rupture is an uncommon but serious complication. We present a case of arterial rupture and subarachnoid haemorrhage during middle cerebral artery stenting, treated by emergency additional, overlapping stenting and balloon tamponade of the dissected vessel. Thrombotic occlusion of the artery was managed by intra-arterial abciximab. Normal vessel patency was re-established within 20 min and the patient recovered with no neurological deficit. (orig.)

  8. Comparison of radial 4D Flow-MRI with perivascular ultrasound to quantify blood flow in the abdomen and introduction of a porcine model of pre-hepatic portal hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Frydrychowicz, A. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University Hospital Schleswig-Holstein, Campus Luebeck, Clinic for Radiology and Nuclear Medicine, Luebeck (Germany); University of Luebeck, Luebeck (Germany); Roldan-Alzate, A. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Mechanical Engineering, Madison (United States); Winslow, E. [University of Wisconsin, Department of Surgery, Madison (United States); Consigny, D.; Campo, C.A.; Motosugi, U. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); Johnson, K.M. [University of Wisconsin, Department of Medical Physics, Madison (United States); Wieben, O. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Medical Physics, Madison (United States); Reeder, S.B. [University of Wisconsin - Madison, Department of Radiology, School of Medicine and Public Health, E3/366 Clinical Science Center, Madison, WI (United States); University of Wisconsin, Department of Medical Physics, Madison (United States); University of Wisconsin, Department of Biomedical Engineering, Madison (United States); University of Wisconsin, Department of Medicine, Madison (United States); University of Wisconsin, Department of Emergency Medicine, Madison (United States)

    2017-12-15

    Objectives of this study were to compare radial time-resolved phase contrast magnetic resonance imaging (4D Flow-MRI) with perivascular ultrasound (pvUS) and to explore a porcine model of acute pre-hepatic portal hypertension (PHTN). Abdominal 4D Flow-MRI and pvUS in portal and splenic vein, hepatic and both renal arteries were performed in 13 pigs of approximately 60 kg. In six pigs, measurements were repeated after partial portal vein (PV) ligature. Inter- and intra-reader comparisons and statistical analysis including Bland-Altman (BA) comparison, paired Student's t tests and linear regression were performed. PvUS and 4D Flow-MRI measurements agreed well; flow before partial PV ligature was 322 ± 30 ml/min in pvUS and 297 ± 27 ml/min in MRI (p = 0.294), and average BA difference was 25 ml/min [-322; 372]. Inter- and intra-reader results differed very little, revealed excellent correlation (R {sup 2} = 0.98 and 0.99, respectively) and resulted in BA differences of -5 ml/min [-161; 150] and -2 ml/min [-28; 25], respectively. After PV ligature, PV flow decreased from 356 ± 50 to 298 ± 61 ml/min (p = 0.02), and hepatic arterial flow increased from 277 ± 36 to 331 ± 65 ml/min (p = n.s.). The successful in vivo comparison of radial 4D Flow-MRI to perivascular ultrasound revealed good agreement of abdominal blood flow although with considerable spread of results. A model of pre-hepatic PHTN was successfully introduced and acute responses monitored. (orig.)

  9. Observational hints of radial migration in disc galaxies from CALIFA

    NARCIS (Netherlands)

    Ruiz-Lara, T.; Pérez, I.; Florido, E.; Sánchez-Blázquez, P.; Méndez-Abreu, J.; Sánchez-Menguiano, L.; Sánchez, S. F.; Lyubenova, M.; Falcón-Barroso, J.; van de Ven, G.; Marino, R. A.; de Lorenzo-Cáceres, A.; Catalán-Torrecilla, C.; Costantin, L.; Bland-Hawthorn, J.; Galbany, L.; García-Benito, R.; Husemann, B.; Kehrig, C.; Márquez, I.; Mast, D.; Walcher, C. J.; Zibetti, S.; Ziegler, B.

    2017-01-01

    Context. According to numerical simulations, stars are not always kept at their birth galactocentric distances but they have a tendency to migrate. The importance of this radial migration in shaping galactic light distributions is still unclear. However, if radial migration is indeed important,

  10. Radial mixing of material in the asterodial zone

    International Nuclear Information System (INIS)

    Ruzmaikina, T.V.; Safronov, V.S.; Weidenschilling, S.J.

    1989-01-01

    The asteroid belt shows radial zoning of compositional structure. The most abundant types are successively S, C and P types from the inner to the outer parts of the main belt, and D type in the Trojan clouds. Boundaries between compositional zones are not sharp, but gradual transitions over scales ∼1 AU in semimajor axis. The authors examine processes for producing this structure before, during and after the accretion of asteroids. The initial structure is established by temperature and composition gradients in the turbulent solar nebula during the collapse of the presolar cloud. The radial scale of the zoning, comparable to the disk thickness, favors disk models with relatively low turbulent viscosity. Radial decay of solid bodies due to gas drag during settling to the central plane and planetesimal formation probably causes only a small degree of mixing, due to the systematic nature of drag-induced motions

  11. Mixed-Degree Spherical Simplex-Radial Cubature Kalman Filter

    Directory of Open Access Journals (Sweden)

    Shiyuan Wang

    2017-01-01

    Full Text Available Conventional low degree spherical simplex-radial cubature Kalman filters often generate low filtering accuracy or even diverge for handling highly nonlinear systems. The high-degree Kalman filters can improve filtering accuracy at the cost of increasing computational complexity; nevertheless their stability will be influenced by the negative weights existing in the high-dimensional systems. To efficiently improve filtering accuracy and stability, a novel mixed-degree spherical simplex-radial cubature Kalman filter (MSSRCKF is proposed in this paper. The accuracy analysis shows that the true posterior mean and covariance calculated by the proposed MSSRCKF can agree accurately with the third-order moment and the second-order moment, respectively. Simulation results show that, in comparison with the conventional spherical simplex-radial cubature Kalman filters that are based on the same degrees, the proposed MSSRCKF can perform superior results from the aspects of filtering accuracy and computational complexity.

  12. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  13. Analysis of radial runout for symmetric and asymmetric HDD spindle motors with rotor eccentricity

    International Nuclear Information System (INIS)

    Kim, T.-J.; Kim, K.-T.; Hwang, S.-M.; Lee, S.-B.; Park, N.-G.

    2001-01-01

    Radial runout of disk drive spindle is one of the major limiting factors in achieving higher track densities in hard disk drives. Mechanical, magnetic and their coupled origins, such as unbalanced mass, reaction forces and magnetic forces, introduce radial runout of spindle motors. In this paper, radial magnetic forces are calculated with respect to the various rotor eccentricities using analytic method. Based on the results of the radial magnetic forces, the radial runout of the spindle motor is analyzed using finite element and transfer matrices. Results show that an asymmetric motor has a worse performance on unbalanced magnetic forces and radial runout when mechanical and magnetic coupling exists

  14. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  15. Percutaneous transluminal angioplasty (PTA) of supra-aortic arteries especially the internal carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Kachel, R.; Basche, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Radiologische Klinik); Heerklotz, I.; Grossmann, K. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Innere Medizin); Endler, S. (Medizinische Akademie, Erfurt (Germany, F.R.). Klinik fuer Neurologie und Psychiatrie)

    1991-06-01

    We present our experience with 105 patients in whom percutaneous transluminal angioplasty was performed in 112 stenosed or occluded supra-aortic arteries. Symtoms of cerebrovascular and/or vertebrobasilar insufficiency were present in 104 of the 105 patients. The angioplasty was successful in 35 stenoses of the internal carotid artery, 2 stenoses of the common carotid artery, 1 stenosis of the external carotid artery, 15 stenoses of the vertebral artery, 3 stenoses of the innominate artery and 44 stenoses of the subclavian artery. There were only 4 minor-complications (2 haematomas, 1 transient ischemic attack, 1 small thrombus of the internal carotid artery which was detected by 111-indium platelet scintigraphy and treated by thrombendarterectomy before the appearance of neurological symptoms). All patients were symptom free after angioplasty. During the observations period of 3 to 109 months (average 58 months) there were only two cases with re-stenosis after subclavian angioplasty. The results of more than 700 personal and international published percutaneous transluminal angioplasties of supra-aortic arteries are presented. The results suggest that angioplasty of supra-aortic arteries is an effective method. On strict definition of the indications, the complication rate for angioplasty of the supra-aortic arteries is not likely to be higher than that for operative treatment. (orig.).

  16. The radial-hedgehog solution in Landau–de Gennes' theory for nematic liquid crystals

    KAUST Repository

    MAJUMDAR, APALA

    2011-09-06

    We study the radial-hedgehog solution in a three-dimensional spherical droplet, with homeotropic boundary conditions, within the Landau-de Gennes theory for nematic liquid crystals. The radial-hedgehog solution is a candidate for a global Landau-de Gennes minimiser in this model framework and is also a prototype configuration for studying isolated point defects in condensed matter physics. The static properties of the radial-hedgehog solution are governed by a non-linear singular ordinary differential equation. We study the analogies between Ginzburg-Landau vortices and the radial-hedgehog solution and demonstrate a Ginzburg-Landau limit for the Landau-de Gennes theory. We prove that the radial-hedgehog solution is not the global Landau-de Gennes minimiser for droplets of finite radius and sufficiently low temperatures and prove the stability of the radial-hedgehog solution in other parameter regimes. These results contain quantitative information about the effect of geometry and temperature on the properties of the radial-hedgehog solution and the associated biaxial instabilities. © Copyright Cambridge University Press 2011.

  17. The radial-hedgehog solution in Landau–de Gennes' theory for nematic liquid crystals

    KAUST Repository

    MAJUMDAR, APALA

    2011-01-01

    We study the radial-hedgehog solution in a three-dimensional spherical droplet, with homeotropic boundary conditions, within the Landau-de Gennes theory for nematic liquid crystals. The radial-hedgehog solution is a candidate for a global Landau-de Gennes minimiser in this model framework and is also a prototype configuration for studying isolated point defects in condensed matter physics. The static properties of the radial-hedgehog solution are governed by a non-linear singular ordinary differential equation. We study the analogies between Ginzburg-Landau vortices and the radial-hedgehog solution and demonstrate a Ginzburg-Landau limit for the Landau-de Gennes theory. We prove that the radial-hedgehog solution is not the global Landau-de Gennes minimiser for droplets of finite radius and sufficiently low temperatures and prove the stability of the radial-hedgehog solution in other parameter regimes. These results contain quantitative information about the effect of geometry and temperature on the properties of the radial-hedgehog solution and the associated biaxial instabilities. © Copyright Cambridge University Press 2011.

  18. Weighted radial dimension: an improved fractal measurement for highway transportation networks distribution

    Science.gov (United States)

    Feng, Yongjiu; Liu, Miaolong; Tong, Xiaohua

    2007-06-01

    An improved fractal measurement, the weighted radial dimension, is put forward for highway transportation networks distribution. The radial dimension (DL), originated from subway investigation in Stuttgart, is a fractal measurement for transportation systems under ideal assumption considering all the network lines to be homogeneous curves, ignoring the difference on spatial structure, quality and level, especially the highway networks. Considering these defects of radial dimension, an improved fractal measurement called weighted radial dimension (D WL) is introduced and the transportation system in Guangdong province is studied in detail using this novel method. Weighted radial dimensions are measured and calculated, and the spatial structure, intensity and connectivity of transportation networks are discussed in Guangdong province and the four sub-areas: the Pearl River Delta area, the East Costal area, the West Costal area and the Northern Guangdong area. In Guangdong province, the fractal spatial pattern characteristics of transportation system vary remarkably: it is the highest in the Pearl River Delta area, moderate in Costal area and lowest in the Northern Guangdong area. With the Pearl River Delta area as the centre, the weighted radial dimensions decrease with the distance increasing, while the decline level is smaller in the costal area and greater in the Northern Guangdong province. By analysis of the conic of highway density, it is recognized that the density decrease with the distance increasing from the calculation centre (Guangzhou), demonstrating the same trend as weighted radial dimensions shown. Evidently, the improved fractal measurement, weighted radial dimension, is an indictor describing the characteristics of highway transportation system more effectively and accurately.

  19. Radial nerve palsy in mid/distal humeral fractures: is early exploration effective?

    Science.gov (United States)

    Keighley, Geffrey; Hermans, Deborah; Lawton, Vidya; Duckworth, David

    2018-03-01

    Radial nerve palsies are a common complication with displaced distal humeral fractures. This case series examines the outcomes of early operative exploration and decompression of the nerve with fracture fixation with the view that this provides a solid construct for optimisation of nerve recovery. A total of 10 consecutive patients with a displaced distal humeral fracture and an acute radial nerve palsy were treated by the senior author by open reduction and internal fixation of the distal humerus and exploration and decompression of the radial nerve. Motor function and sensation of the radial nerve was assessed in the post-operative period every 2 months or until full recovery of the radial nerve function had occurred. All patients (100%) had recovery of motor and sensation function of their upper limb in the radial nerve distribution over a 12-month period. Recovery times ranged between 4 and 32 weeks, with the median time to recovery occurring at 26 weeks and the average time to full recovery being 22.9 weeks. Wrist extension recovered by an average of 3 months (range 2-26 weeks) and then finger extension started to recover 2-6 weeks after this. Disability of the arm, shoulder and hand scores ranged from 0 to 11.8 at greater than 1 year post-operatively. Our study demonstrated that early operative exploration of the radial nerve when performing an open stabilization of displaced distal humeral fractures resulted in a 100% recovery of the radial nerve. © 2017 Royal Australasian College of Surgeons.

  20. Observational hints of radial migration in disc galaxies from CALIFA

    Science.gov (United States)

    Ruiz-Lara, T.; Pérez, I.; Florido, E.; Sánchez-Blázquez, P.; Méndez-Abreu, J.; Sánchez-Menguiano, L.; Sánchez, S. F.; Lyubenova, M.; Falcón-Barroso, J.; van de Ven, G.; Marino, R. A.; de Lorenzo-Cáceres, A.; Catalán-Torrecilla, C.; Costantin, L.; Bland-Hawthorn, J.; Galbany, L.; García-Benito, R.; Husemann, B.; Kehrig, C.; Márquez, I.; Mast, D.; Walcher, C. J.; Zibetti, S.; Ziegler, B.; Califa Team

    2017-07-01

    Context. According to numerical simulations, stars are not always kept at their birth galactocentric distances but they have a tendency to migrate. The importance of this radial migration in shaping galactic light distributions is still unclear. However, if radial migration is indeed important, galaxies with different surface brightness (SB) profiles must display differences in their stellar population properties. Aims: We investigate the role of radial migration in the light distribution and radial stellar content by comparing the inner colour, age, and metallicity gradients for galaxies with different SB profiles. We define these inner parts, avoiding the bulge and bar regions and up to around three disc scale lengths (type I, pure exponential) or the break radius (type II, downbending; type III, upbending). Methods: We analysed 214 spiral galaxies from the CALIFA survey covering different SB profiles. We made use of GASP2D and SDSS data to characterise the light distribution and obtain colour profiles of these spiral galaxies. The stellar age and metallicity profiles were computed using a methodology based on full-spectrum fitting techniques (pPXF, GANDALF, and STECKMAP) to the Integral Field Spectroscopic CALIFA data. Results: The distributions of the colour, stellar age, and stellar metallicity gradients in the inner parts for galaxies displaying different SB profiles are unalike as suggested by Kolmogorov-Smirnov and Anderson-Darling tests. We find a trend in which type II galaxies show the steepest profiles of all, type III show the shallowest, and type I display an intermediate behaviour. Conclusions: These results are consistent with a scenario in which radial migration is more efficient for type III galaxies than for type I systems, where type II galaxies present the lowest radial migration efficiency. In such a scenario, radial migration mixes the stellar content, thereby flattening the radial stellar properties and shaping different SB profiles. However

  1. Long-term facial artery catheter implantation for serial arterial blood sampling and invasive arterial blood pressure measurement in horses.

    Science.gov (United States)

    Dias, Deborah Penteado Martins; Teixeira, Luisa Gouvêa; Canola, Paulo Aléscio; Albernaz, Raquel Mincarelli; Marques, José Antônio; Neto, José Corrêa de Lacerda

    2012-06-01

    The purpose of this investigation was to evaluate surgical catheter implantation in the facial artery of horses and the long-term maintenance of such arteries using heparin and ascorbic acid as filling solution. Nine horses were implanted with a polyurethane catheter. The catheters were flushed with a heparin/ascorbic acid solution every 8h and remained patent for 25 days. Arterial blood samples were collected twice a day, and one exercise test that included serial blood samples and arterial pressure recordings was performed on a treadmill. Polyurethane catheters surgically implanted in the facial artery can be kept patent by filling with a heparin/ascorbic acid solution and provide convenient invasive arterial access in horses which is suitable for use for serial blood sampling and blood pressure recordings, even during exercise on treadmill. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  3. Radially global δf computation of neoclassical phenomena in a tokamak pedestal

    International Nuclear Information System (INIS)

    Landreman, Matt; Parra, Felix I; Catto, Peter J; Ernst, Darin R; Pusztai, Istvan

    2014-01-01

    Conventional radially-local neoclassical calculations become inadequate if the radial gradient scale lengths of the H-mode pedestal become as small as the poloidal ion gyroradius. Here, we describe a radially global δf continuum code that generalizes neoclassical calculations to allow for stronger gradients. As with conventional neoclassical calculations, the formulation is time-independent and requires only the solution of a single sparse linear system. We demonstrate precise agreement with an asymptotic analytic solution of the radially global kinetic equation in the appropriate limits of aspect ratio and collisionality. This agreement depends crucially on accurate treatment of finite orbit width effects. (paper)

  4. Arterial occlusion to treat basilar artery dissecting aneurysm

    NARCIS (Netherlands)

    Cui, Qing Ke; Liu, Wei Dong; Liu, Peng; Li, Xue Yuan; Zhang, Lian Qun; Ma, Long Jia; Ren, Yun Fei; Wu, Ya Ping; Wang, Zhi Gang

    2015-01-01

    Object: To explore the clinical feasibility of employing occlusion to treat basilar artery dissecting aneurysm. Methods: One patient, male and 46 years old, suffered transient numbness and weakness on the right limbs. Cerebral angiography indicated basilar artery dissecting aneurysm. The patient

  5. Experiences in the creation of an electromyography database to help hand amputated persons.

    Science.gov (United States)

    Atzori, Manfredo; Gijsberts, Arjan; Heynen, Simone; Hager, Anne-Gabrielle Mittaz; Castellimi, Claudio; Caputo, Barbara; Müller, Henning

    2012-01-01

    Currently, trans-radial amputees can only perform a few simple movements with prosthetic hands. This is mainly due to low control capabilities and the long training time that is required to learn controlling them with surface electromyography (sEMG). This is in contrast with recent advances in mechatronics, thanks to which mechanical hands have multiple degrees of freedom and in some cases force control. To help improve the situation, we are building the NinaPro (Non-Invasive Adaptive Prosthetics) database, a database of about 50 hand and wrist movements recorded from several healthy and currently very few amputated persons that will help the community to test and improve sEMG-based natural control systems for prosthetic hands. In this paper we describe the experimental experiences and practical aspects related to the data acquisition.

  6. Effects of Radial Gap Ratio between Impeller and Vaned Diffuser on Performance of Centrifugal Compressors

    Directory of Open Access Journals (Sweden)

    Mohammadjavad Hosseini

    2017-07-01

    Full Text Available A high-performance centrifugal compressor is needed for numerous industry applications nowadays. The radial gap ratio between the impeller and the diffuser vanes plays an important role in the improvement of the compressor performance. In this paper, the effects of the radial gap ratio on a high-pressure ratio centrifugal compressor are investigated using numerical simulations. The performance and the flow field are compared for six different radial gap ratios and five rotational speeds. The minimal radial gap ratio was 1.04 and the maximal was 1.14. Results showed that reducing the radial gap ratio decreases the choke mass flow rate. For the tip-speed Mach number (impeller inlet with Mu < 1, the pressure recovery and the loss coefficients are not sensitive to the radial gap ratio. However, for Mu ≥ 1, the best radial gap ratio is 1.08 for the pressure recovery and the loss coefficients. Furthermore, the impeller pressure ratio and efficiency are reduced by increasing the radial gap ratio. Finally, the compressor efficiency was compared for different radial gap ratios. For Mu < 1, the radial gap ratio does not have noticeable effects. In comparison, the radial gap ratio of 1.08 has the best performance for Mu ≥ 1.

  7. Spiral CT angiography (SCTA) study of celiac artery and superior mesenteric artery

    International Nuclear Information System (INIS)

    Yuan Zhenguo; Zhou Cunsheng; Xu Zuodong; Shi Hao; Wang Tao

    1999-01-01

    Objective: To study the visualization capability and scanning technique of SCTA in celiac artery, superior mesenteric artery (SMA) and other branches. Methods: Thirty patients, with normal abdominal SCTA results, were given small injection test dose after plain scan. The abdominal aorta parallel to the body of pancreas was chosen as target vessel, the peak-time plus 2 seconds as the best delay scan time. Iodine contrast medium 90∼110 ml was injected into antecubital vein at the speed of 3.5 ml/s, then scan from cranial to caudal was performed. Pitch 1.0 and slice thickness 3.2 mm were selected as the scan parameters. Maximum intensity projection (MaxIP) was employed in all patients and shaded surface display (SSD) in 23 cases. Results: The display rate using MaxIP and SSD of celiac artery, splenic artery, common hepatic artery, proper hepatic artery and SMA were all 100%, the gastroduodenal artery 100% and 91%, the left gastric artery 83% and 87%, respectively. Conclusions: SCTA as a minimally invasive examination is a valuable method to detect and diagnose disease or variations of celiac artery, its branches and SMA. Spiral scanning technique and image processing have a decisive effect on the image quality

  8. Propagation of a radial phased-locked Lorentz beam array in turbulent atmosphere.

    Science.gov (United States)

    Zhou, Guoquan

    2011-11-21

    A radial phased-locked (PL) Lorentz beam array provides an appropriate theoretical model to describe a coherent diode laser array, which is an efficient radiation source for high-power beaming use. The propagation of a radial PL Lorentz beam array in turbulent atmosphere is investigated. Based on the extended Huygens-Fresnel integral and some mathematical techniques, analytical formulae for the average intensity and the effective beam size of a radial PL Lorentz beam array are derived in turbulent atmosphere. The average intensity distribution and the spreading properties of a radial PL Lorentz beam array in turbulent atmosphere are numerically calculated. The influences of the beam parameters and the structure constant of the atmospheric turbulence on the propagation of a radial PL Lorentz beam array in turbulent atmosphere are discussed in detail. © 2011 Optical Society of America

  9. Study on the radial vibration and acoustic field of an isotropic circular ring radiator.

    Science.gov (United States)

    Lin, Shuyu; Xu, Long

    2012-01-01

    Based on the exact analytical theory, the radial vibration of an isotropic circular ring is studied and its electro-mechanical equivalent circuit is obtained. By means of the equivalent circuit model, the resonance frequency equation is derived; the relationship between the radial resonance frequency, the radial displacement amplitude magnification and the geometrical dimensions, the material property is analyzed. For comparison, numerical method is used to simulate the radial vibration of isotropic circular rings. The resonance frequency and the radial vibrational displacement distribution are obtained, and the radial radiation acoustic field of the circular ring in radial vibration is simulated. It is illustrated that the radial resonance frequencies from the analytical method and the numerical method are in good agreement when the height is much less than the radius. When the height becomes large relative to the radius, the frequency deviation from the two methods becomes large. The reason is that the exact analytical theory is limited to thin circular ring whose height must be much less than its radius. Copyright © 2011 Elsevier B.V. All rights reserved.

  10. Surface interpolation with radial basis functions for medical imaging

    International Nuclear Information System (INIS)

    Carr, J.C.; Beatson, R.K.; Fright, W.R.

    1997-01-01

    Radial basis functions are presented as a practical solution to the problem of interpolating incomplete surfaces derived from three-dimensional (3-D) medical graphics. The specific application considered is the design of cranial implants for the repair of defects, usually holes, in the skull. Radial basis functions impose few restrictions on the geometry of the interpolation centers and are suited to problems where interpolation centers do not form a regular grid. However, their high computational requirements have previously limited their use to problems where the number of interpolation centers is small (<300). Recently developed fast evaluation techniques have overcome these limitations and made radial basis interpolation a practical approach for larger data sets. In this paper radial basis functions are fitted to depth-maps of the skull's surface, obtained from X-ray computed tomography (CT) data using ray-tracing techniques. They are used to smoothly interpolate the surface of the skull across defect regions. The resulting mathematical description of the skull's surface can be evaluated at any desired resolution to be rendered on a graphics workstation or to generate instructions for operating a computer numerically controlled (CNC) mill

  11. An axially averaged-radial transport model of tokamak edge plasmas

    International Nuclear Information System (INIS)

    Prinja, A.K.; Conn, R.W.

    1984-01-01

    A two-zone axially averaged-radial transport model for edge plasmas is described that incorporates parallel electron and ion conduction, localized recycling, parallel electron pressure gradient effects and sheath losses. Results for high recycling show that the radial electron temperature profile is determined by parallel electron conduction over short radial distances (proportional 3 cm). At larger radius where Tsub(e) has fallen appreciably, convective transport becomes equally important. The downstream density and ion temperature profiles are very flat over the region where electron conduction dominates. This is seen to result from a sharply decaying velocity profile that follows the radial electron temperature. A one-dimensional analytical recycling model shows that at high neutral pumping rates, the plasma density at the plate, nsub(ia), scales linearly with the unperturbed background density, nsub(io). When ionization dominates nsub(ia)/nsub(io) proportional exp(nsub(io)) while in the intermediate regime nsub(ia)/nsub(io) proportional exp(proportional nsub(io)). Such behavior is qualitatively in accord with experimental observations. (orig.)

  12. Optical cage generated by azimuthal- and radial-variant vector beams.

    Science.gov (United States)

    Man, Zhongsheng; Bai, Zhidong; Li, Jinjian; Zhang, Shuoshuo; Li, Xiaoyu; Zhang, Yuquan; Ge, Xiaolu; Fu, Shenggui

    2018-05-01

    We propose a method to generate an optical cage using azimuthal- and radial-variant vector beams in a high numerical aperture optical system. A new kind of vector beam that has azimuthal- and radial-variant polarization states is proposed and demonstrated theoretically. Then, an integrated analytical model to calculate the electromagnetic field and Poynting vector distributions of the input azimuthal- and radial-variant vector beams is derived and built based on the vector diffraction theory of Richards and Wolf. From calculations, a full polarization-controlled optical cage is obtained by simply tailoring the radial index of the polarization, the uniformity U of which is up to 0.7748, and the cleanness C is zero. Additionally, a perfect optical cage can be achieved with U=1, and C=0 by introducing an amplitude modulation; its magnetic field and energy flow are also demonstrated in detail. Such optical cages may be helpful in applications such as optical trapping and high-resolution imaging.

  13. Linear radial pulsation theory. Lecture 5

    International Nuclear Information System (INIS)

    Cox, A.N.

    1983-01-01

    We describe a method for getting an equilibrium stellar envelope model using as input the total mass, the envelope mass, the surface effective temperature, the total surface luminosity, and the composition of the envelope. Then wih the structure of the envelope model known, we present a method for obtaining the raidal pulsation periods and growth rates for low order modes. The large amplitude pulsations observed for the yellow and red giants and supergiants are always these radial models, but for the stars nearer the main sequence, as for all of our stars and for the white dwarfs, there frequently are nonradial modes occuring also. Application of linear theory radial pulsation theory is made to the giant star sigma Scuti variables, while the linear nonradial theory will be used for the B stars in later lectures

  14. Calculation of arterial wall temperature in atherosclerotic arteries: effect of pulsatile flow, arterial geometry, and plaque structure

    Directory of Open Access Journals (Sweden)

    Kim Taehong

    2007-03-01

    Full Text Available Abstract Background This paper presents calculations of the temperature distribution in an atherosclerotic plaque experiencing an inflammatory process; it analyzes the presence of hot spots in the plaque region and their relationship to blood flow, arterial geometry, and inflammatory cell distribution. Determination of the plaque temperature has become an important topic because plaques showing a temperature inhomogeneity have a higher likelihood of rupture. As a result, monitoring plaque temperature and knowing the factors affecting it can help in the prevention of sudden rupture. Methods The transient temperature profile in inflamed atherosclerotic plaques is calculated by solving an energy equation and the Navier-Stokes equations in 2D idealized arterial models of a bending artery and an arterial bifurcation. For obtaining the numerical solution, the commercial package COMSOL 3.2 was used. The calculations correspond to a parametric study where arterial type and size, as well as plaque geometry and composition, are varied. These calculations are used to analyze the contribution of different factors affecting arterial wall temperature measurements. The main factors considered are the metabolic heat production of inflammatory cells, atherosclerotic plaque length lp, inflammatory cell layer length lmp, and inflammatory cell layer thickness dmp. Results The calculations indicate that the best location to perform the temperature measurement is at the back region of the plaque (0.5 ≤ l/lp ≤ 0.7. The location of the maximum temperature, or hot spot, at the plaque surface can move during the cardiac cycle depending on the arterial geometry and is a direct result of the blood flow pattern. For the bending artery, the hot spot moves 0.6 millimeters along the longitudinal direction; for the arterial bifurcation, the hot spot is concentrated at a single location due to the flow recirculation observed at both ends of the plaque. Focusing on the

  15. Dynamic contrast-enhanced ultrasound and transient arterial occlusion for quantification of arterial perfusion reserve in peripheral arterial disease

    International Nuclear Information System (INIS)

    Amarteifio, E.; Wormsbecher, S.; Krix, M.; Demirel, S.; Braun, S.; Delorme, S.; Böckler, D.; Kauczor, H.-U.; Weber, M.-A.

    2012-01-01

    Objective: To quantify muscular micro-perfusion and arterial perfusion reserve in peripheral arterial disease (PAD) with dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion. Materials and methods: This study had local institutional review board approval and written informed consent was obtained from all subjects. We examined the dominant lower leg of 40 PAD Fontaine stage IIb patients (mean age, 65 years) and 40 healthy volunteers (mean age, 54 years) with CEUS (7 MHz; MI, 0.28) during continuous intravenous infusion of 4.8 mL microbubbles. Transient arterial occlusion at mid-thigh level simulated physical exercise. With time–CEUS–intensity curves obtained from regions of interest within calf muscles, we derived the maximum CEUS signal after occlusion (max) and its time (t max ), slope to maximum (m), vascular response after occlusion (AUC post ), and analysed accuracy, receiver operating characteristic (ROC) curves, and correlations with ankle-brachial index (ABI) and walking distance. Results: All parameters differed in PAD and volunteers (p max was delayed (31.2 ± 13.6 vs. 16.7 ± 8.5 s, p post as optimal parameter combination for diagnosing PAD and therefore impaired arterial perfusion reserve. Conclusions: Dynamic CEUS with transient arterial occlusion quantifies muscular micro-perfusion and arterial perfusion reserve. The technique is accurate to diagnose PAD.

  16. Optimization of a radially cooled pebble bed reactor - HTR2008-58117

    International Nuclear Information System (INIS)

    Boer, B.; Kloosterman, J. L.; Lathouwers, D.; Van Der Hagen, T. H. J. J.; Van Dam, H.

    2008-01-01

    By altering the coolant flow direction in a pebble bed reactor from axial to radial, the pressure drop can be reduced tremendously. In this case the coolant flows from the outer reflector through the pebble bed and finally to flow paths in the inner reflector. As a consequence, the fuel temperatures are elevated due to the reduced heat transfer of the coolant. However, the power profile and pebble size in a radially cooled pebble bed reactor can be optimized to achieve lower fuel temperatures than current axially cooled designs, while the low pressure drop can be maintained. The radial power profile in the core can be altered by adopting multi-pass fuel management using several radial fuel zones in the core. The optimal power profile yielding a flat temperature profile is derived analytically and is approximated by radial fuel zoning. In this case, the pebbles pass through the outer region of the core first and each consecutive pass is located in a fuel zone closer to the inner reflector. Thereby, the resulting radial distribution of the fissile material in the core is influenced and the temperature profile is close to optimal. The fuel temperature in the pebbles can be further reduced by reducing the standard pebble diameter from 6 cm to a value as low as I cm. An analytical investigation is used to demonstrate the effects on the fuel temperature and pressure drop for both radial and axial cooling. Finally, two-dimensional numerical calculations were performed, using codes for neutronics, thermal-hydraulics and fuel depletion analysis, in order to validate the results for the optimized design that were obtained from the analytical investigations. It was found that for a radially cooled design with an optimized power profile and reduced pebble diameter (below 3.5 cm) both a reduction in the pressure drop (Δp = -2.6 bar), which increases the reactor efficiency with several percent, and a reduction in the maximum fuel temperature (ΔT = -50 deg. C) can be achieved

  17. Venous digital subtraction angiography for diagnosis of renal artery stenosis in arterial hypertony

    International Nuclear Information System (INIS)

    Schoerner, W.; Kempter, H.; Banzer, D.; Aviles, C.; Weiss, T.; Felix, R.

    1984-01-01

    Venous digital subtraction angiography was performed in 248 patients for the diagnosis of renal arterial stenosis. In 88% of the investigations the stenosis could be found. Comparison of digital angiography and conventional angiography was made for 57 renal arteries (25 investigations). In 52 renal arteries we found the same results with both methods, in 5 renal arteries we found the same results with both methods, in 5 renal arteries the digital angiography showed false positive results. The spatial resolution of digital subtraction angiography is sufficient for the correct diagnosis of significant renal arterial stenosis. With regard to the lower invasion of digital subtraction angiography compared to conventional angiography the first method should be used for clarification of renal arterial hypertension. (orig.)

  18. Radiographic study of distal radial physeal closure in thoroughbred horses

    International Nuclear Information System (INIS)

    Vulcano, L.C.; Mamprim, M.J.; Muniz, L.M.R.; Moreira, A.F.; Luna, S.P.L.

    1997-01-01

    Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively

  19. Effects of relativistic small radial component on atomic photoionization cross sections

    International Nuclear Information System (INIS)

    Liu Xiaobin; Xing Yongzhong; Sun Xiaowei

    2008-01-01

    The effects of relativistic small radial component on atomic photoionization cross sections have been studied within relativistic average self-consistent field theory. Relativistic effects are relatively unimportant for low photon energy, along with a review of high-energy photoionization the relativistic effects are quite important. The effects of relativistic small radial component on photoionization process should show breakdown when the nuclear finite-size effects is taken into account. The compression of wavefunction into the space near nucleus is so strong in highly charged ions that the electronic radius greatly decreases, and the effects of relativistic small radial component on photoionization cross sections turn to stronger than ordinary atoms. Since relativistic effects are extremely sensitive to the behavior of small radial component, the results are in good agreement with relativistic effects on photoionization cross section. (authors)

  20. Bessel-like beams modulated by arbitrary radial functions

    Science.gov (United States)

    Herman; Wiggins

    2000-06-01

    An approximate method for determining the radial and axial intensity of a Bessel-like beam is presented for the general case in which a radial Bessel distribution of any order is modulated by an arbitrary function. For Bessel-Gauss, generalized Bessel-Gauss, and Bessel-super-Gauss beams, this simple approximation yields results that are very close to the exact values, while they are exact for Bessel beams. A practical beam that can be generated with a combination of simple lenses is also analyzed and illustrated.

  1. Bilateral radial neck fractures – A Case Report

    Directory of Open Access Journals (Sweden)

    ABY Ng

    2007-11-01

    Full Text Available Radial head and neck fractures are the most frequently seen elbow fractures. The usual cause of this injury is a fall onto an outstretched hand with a partly flexed elbow. We report here an unusual case of bilateral non-displaced radial neck fractures in a patient who presented with complaints of pain in both elbows following a simple fall. This case highlights the need for a high index of suspicion in the diagnosis of multiple injuries, no matter how `trivial` the mechanism of injury.

  2. Relationship between neck circumference, insulin resistance and arterial stiffness in overweight and obese subjects.

    Science.gov (United States)

    Fantin, Francesco; Comellato, Gabriele; Rossi, Andrea P; Grison, Elisa; Zoico, Elena; Mazzali, Gloria; Zamboni, Mauro

    2017-09-01

    Background Only a few studies have investigated the relationship between neck circumference and cardiometabolic risk. The aim of this study was to assess the relationships between neck circumference, waist circumference, metabolic variables and arterial stiffness in a group of overweight and obese subjects evaluating a possible independent role of neck circumference in determining arterial stiffness. Methods and results We studied 95 subjects (53 women) with an age range of 20-77 years and body mass index range from 25.69 to 47.04 kg/m 2 . In each subject we evaluated body mass index, waist, hip and neck circumference, systolic and diastolic blood pressure, insulin, fasting glucose, cholesterol, low-density lipoprotein and high-density lipoprotein cholesterol and triglycerides. Arterial stiffness was assessed by carotid-femoral pulse wave velocity (PWVcf) and carotid-radial pulse wave velocity (PWVcr). Both PWVcf and PWVcr were higher in subjects with high values of neck circumference compared with subjects with normal values of neck circumference. Subjects with high values of neck circumference and abdominal obesity presented higher values of mean arterial pressure, PWVcr and homeostasis model assessment (HOMA) index and lower values of high-density lipoprotein than subjects with only abdominal obesity. Two models of stepwise multiple regression were performed in order to evaluate the combined effect of independent variables on arterial stiffness. In the first model PWVcf was considered a dependent variable, and age, gender, systolic blood pressure, triglycerides, high-density lipoprotein cholesterol, waist circumference, neck circumference, HOMA index and the use of anti-hypertensive medications were considered independent variables. Age, systolic blood pressure, triglycerides and waist circumference were significant predictors of PWVcf, explaining 65% of its variance. In the second model, in which PWVcr was considered a dependent variable, neck circumference

  3. Effects of cranberry juice consumption on vascular function in patients with coronary artery disease.

    Science.gov (United States)

    Dohadwala, Mustali M; Holbrook, Monika; Hamburg, Naomi M; Shenouda, Sherene M; Chung, William B; Titas, Megan; Kluge, Matthew A; Wang, Na; Palmisano, Joseph; Milbury, Paul E; Blumberg, Jeffrey B; Vita, Joseph A

    2011-05-01

    Cranberry juice contains polyphenolic compounds that could improve endothelial function and reduce cardiovascular disease risk. The objective was to examine the effects of cranberry juice on vascular function in subjects with coronary artery disease. We completed an acute pilot study with no placebo (n = 15) and a chronic placebo-controlled crossover study (n = 44) that examined the effects of cranberry juice on vascular function in subjects with coronary artery disease. In the chronic crossover study, subjects with coronary heart disease consumed a research preparation of double-strength cranberry juice (54% juice, 835 mg total polyphenols, and 94 mg anthocyanins) or a matched placebo beverage (480 mL/d) for 4 wk each with a 2-wk rest period between beverages. Beverage order was randomly assigned, and participants refrained from consuming other flavonoid-containing beverages during the study. Vascular function was measured before and after each beverage, with follow-up testing ≥12 h after consumption of the last beverage. Mean (±SD) carotid-femoral pulse wave velocity, a measure of central aortic stiffness, decreased after cranberry juice (8.3 ± 2.3 to 7.8 ± 2.2 m/s) in contrast with an increase after placebo (8.0 ± 2.0 to 8.4 ± 2.8 m/s) (P = 0.003). Brachial artery flow-mediated dilation, digital pulse amplitude tonometry, blood pressure, and carotid-radial pulse wave velocity did not change. In the uncontrolled pilot study, we observed improved brachial artery flow-mediated dilation (7.7 ± 2.9% to 8.7 ± 3.1%, P = 0.01) and digital pulse amplitude tonometry ratio (0.10 ± 0.12 to 0.23 ± 0.16, P = 0.001) 4 h after consumption of a single 480-mL portion of cranberry juice. Chronic cranberry juice consumption reduced carotid femoral pulse wave velocity-a clinically relevant measure of arterial stiffness. The uncontrolled pilot study suggested an acute benefit; however, no chronic effect on measures of endothelial vasodilator function was found. This trial

  4. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Directory of Open Access Journals (Sweden)

    Amann Matthias

    2007-11-01

    Full Text Available Abstract Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC measurement by the pulmonary artery catheter (PAC. However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years, who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min. The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC and percentage changes in COAP (ΔCOAP for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p PAC and ΔCOAP was 0.46 (p Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore, the used algorithm (V 1.03 failed to

  5. Evaluation of a new arterial pressure-based cardiac output device requiring no external calibration

    Science.gov (United States)

    Prasser, Christopher; Bele, Sylvia; Keyl, Cornelius; Schweiger, Stefan; Trabold, Benedikt; Amann, Matthias; Welnhofer, Julia; Wiesenack, Christoph

    2007-01-01

    Background Several techniques have been discussed as alternatives to the intermittent bolus thermodilution cardiac output (COPAC) measurement by the pulmonary artery catheter (PAC). However, these techniques usually require a central venous line, an additional catheter, or a special calibration procedure. A new arterial pressure-based cardiac output (COAP) device (FloTrac™, Vigileo™; Edwards Lifesciences, Irvine, CA, USA) only requires access to the radial or femoral artery using a standard arterial catheter and does not need an external calibration. We validated this technique in critically ill patients in the intensive care unit (ICU) using COPAC as the method of reference. Methods We studied 20 critically ill patients, aged 16 to 74 years (mean, 55.5 ± 18.8 years), who required both arterial and pulmonary artery pressure monitoring. COPAC measurements were performed at least every 4 hours and calculated as the average of 3 measurements, while COAP values were taken immediately at the end of bolus determinations. Accuracy of measurements was assessed by calculating the bias and limits of agreement using the method described by Bland and Altman. Results A total of 164 coupled measurements were obtained. Absolute values of COPAC ranged from 2.80 to 10.80 l/min (mean 5.93 ± 1.55 l/min). The bias and limits of agreement between COPAC and COAP for unequal numbers of replicates was 0.02 ± 2.92 l/min. The percentage error between COPAC and COAP was 49.3%. The bias between percentage changes in COPAC (ΔCOPAC) and percentage changes in COAP (ΔCOAP) for consecutive measurements was -0.70% ± 32.28%. COPAC and COAP showed a Pearson correlation coefficient of 0.58 (p < 0.01), while the correlation coefficient between ΔCOPAC and ΔCOAP was 0.46 (p < 0.01). Conclusion Although the COAP algorithm shows a minimal bias with COPAC over a wide range of values in an inhomogeneous group of critically ill patients, the scattering of the data remains relative wide. Therefore

  6. Radial Color Gradient in a Globular Cluster 1. M68

    Directory of Open Access Journals (Sweden)

    Sukyoung Yi

    1990-12-01

    Full Text Available Stars in M68 from the observed color-magnitude diagrams with CCD were integrated to find any radial gradient. The result shows that M68 has a slightly bluer core. The main cause of these calculated radial color variations seems to come from the random distribution of giants.

  7. Imaging of Dual Ophthalmic Arteries: Identification of the Central Retinal Artery

    Directory of Open Access Journals (Sweden)

    Louise Louw

    2014-01-01

    Full Text Available Identification of the origin of the central retinal artery (CRA is imperative in tailoring angiographic studies to resolve a given clinical problem. A case with dual ophthalmic arteries (OAs, characterized by different origins and distinct branching patterns, is documented for training purposes. Pre-clinical diagnosis of a 9-year-old child who presented with a sharp wire in the left-side eyeball was primarily corneal laceration. For imaging, a selected six-vessel angiographic study with the transfemoral approach was performed. Embolization was not required and the wire could be successfully removed. Right-side OA anatomy was normal, while left-side dual OAs with external carotid artery (ECA and internal carotid artery (ICA origins were seen. The case presented with a left-side meningo-ophthalmic artery (M-OA anomaly via the ECA, marked by a middle meningeal artery (MMA (origin: Maxillary artery; course: Through foramen spinosum with normal branches (i.e. anterior and posterior branches, and an OA variant (course: Through superior orbital fissure with a distinct orbital branching pattern. A smaller OA (origin: ICA; course: Through optic foramen with a distinct ocular branching pattern presented with the central retinal artery (CRA. The presence of the dual OAs and the M-OA anomaly can be explained by disturbed evolutionary changes of the primitive OA and stapedial artery during development. The surgical interventionist must be aware of dual OAs and M-OA anomalies with branching pattern variations on retinal supply, because of dangerous extracranial-intracranial anastomotic connections. It is of clinical significance that the origin of the CRA from the ICA or ECA must be determined to avoid complications to the vision.

  8. Relationship of daily arterial blood pressure monitoring readings and arterial stiffness profile in male patients with chronic obstructive pulmonary disease combined with arterial hypertension

    Directory of Open Access Journals (Sweden)

    Karoli N.A.

    2013-06-01

    Full Text Available The aim of the study was to determine correlation between arterial blood pressure daily rhythm and daily profile of arterial stiffness in male patients with chronic obstructive pulmonary disease (COPD and arterial hypertension. Materials et methods: Prospective investigation comprised 45 male patients with COPD and arterial hypertension. Individuals of 40 years younger and 80 years elder, patients with diabetes, stroke, angina pectoris, or heart infarction, vascular diseases, and exacerbation of chronic disease, bronchial and pulmonary diseases of other etiology were excluded from the analyses. Comparison group included 47 patients with essential arterial hypertension and without chronic respiratory diseases closely similar on general parameters with patients from main clinical series. Twenty-four-hour arterial blood pressure monitoring (ABPM and daily arterial stiffness monitoring were performed using BPLab® MnSDP-2 apparatus (Petr Telegin, Russian Federation. Results: Patients with COPD combined with arterial hypertension with raised arterial stiffness measures prevail over individuals in essential hypertension group. There is pathological alteration of the ABPM circadian rhythm and raised «Pressure load» values in raised arterial stiffness group. Conclusion: We found ABPM raised parameters in patients with COPD and arterial hypertension. It confirms necessity of ABPM in daily arterial stiffness assessment in patients with COPD.

  9. Management of post-traumatic elbow instability after failed radial head excision: A case report

    Directory of Open Access Journals (Sweden)

    Georgios Touloupakis

    2017-02-01

    Full Text Available Radial head excision has always been a safe commonly used surgical procedure with a satisfactory clinical outcome for isolated comminuted radial head fractures. However, diagnosis of elbow instability is still very challenging and often underestimated in routine orthopaedic evaluation. We present the case of a 21-years old female treated with excision after radial head fracture, resulting in elbow instability. The patient underwent revision surgery after four weeks. We believe that ligament reconstruction without radial head substitution is a safe alternative choice for Mason III radial head fractures accompanied by complex ligament lesions.

  10. Autorefraction versus subjective refraction in a radially asymmetric multifocal intraocular lens

    NARCIS (Netherlands)

    Linden, J.W.M. van der; Vrijman, V.; El-Saady, R.; Meulen, I.J. van der; Mourits, M.P.; Lapid-Gortzak, R.

    2014-01-01

    PURPOSE: To evaluate whether the automated refraction (AR) correlates with subjective manifest (MR) refraction in eyes implanted with radially asymmetric multifocal intraocular lens (IOLs). METHODS: This retrospective study evaluated 52 eyes (52 patients) implanted with a radially asymmetric

  11. RTOD- RADIAL TURBINE OFF-DESIGN PERFORMANCE ANALYSIS

    Science.gov (United States)

    Glassman, A. J.

    1994-01-01

    The RTOD program was developed to accurately predict radial turbine off-design performance. The radial turbine has been used extensively in automotive turbochargers and aircraft auxiliary power units. It is now being given serious consideration for primary powerplant applications. In applications where the turbine will operate over a wide range of power settings, accurate off-design performance prediction is essential for a successful design. RTOD predictions have already illustrated a potential improvement in off-design performance offered by rotor back-sweep for high-work-factor radial turbines. RTOD can be used to analyze other potential performance enhancing design features. RTOD predicts the performance of a radial turbine (with or without rotor blade sweep) as a function of pressure ratio, speed, and stator setting. The program models the flow with the following: 1) stator viscous and trailing edge losses; 2) a vaneless space loss between the stator and the rotor; and 3) rotor incidence, viscous, trailing-edge, clearance, and disk friction losses. The stator and rotor viscous losses each represent the combined effects of profile, endwall, and secondary flow losses. The stator inlet and exit and the rotor inlet flows are modeled by a mean-line analysis, but a sector analysis is used at the rotor exit. The leakage flow through the clearance gap in a pivoting stator is also considered. User input includes gas properties, turbine geometry, and the stator and rotor viscous losses at a reference performance point. RTOD output includes predicted turbine performance over a specified operating range and any user selected flow parameters. The RTOD program is written in FORTRAN IV for batch execution and has been implemented on an IBM 370 series computer with a central memory requirement of approximately 100K of 8 bit bytes. The RTOD program was developed in 1983.

  12. Turbulence in tokamak plasmas. Effect of a radial electric field shear

    International Nuclear Information System (INIS)

    Payan, J.

    1994-05-01

    After a review of turbulence and transport phenomena in tokamak plasmas and the radial electric field shear effect in various tokamaks, experimental measurements obtained at Tore Supra by the means of the ALTAIR plasma diagnostic technique, are presented. Electronic drift waves destabilization mechanisms, which are the main features that could describe the experimentally observed microturbulence, are then examined. The effect of a radial electric field shear on electronic drift waves is then introduced, and results with ohmic heating are studied together with relations between turbulence and transport. The possible existence of ionic waves is rejected, and a spectral frequency modelization is presented, based on the existence of an electric field sheared radial profile. The position of the inversion point of this field is calculated for different values of the mean density and the plasma current, and the modelization is applied to the TEXT tokamak. The radial electric field at Tore Supra is then estimated. The effect of the ergodic divertor on turbulence and abnormal transport is then described and the density fluctuation radial profile in presence of the ergodic divertor is modelled. 80 figs., 120 refs

  13. Leakage Account for Radial Face Contact Seal in Aircraft Engine Support

    Science.gov (United States)

    Vinogradov, A. S.; Sergeeva, T. V.

    2018-01-01

    The article is dedicated to the development of a methodology for the radial face contact seal design taking into consideration the supporting elements deformations in different aircraft engine operating modes. Radial face contact seals are popular in the aircraft engines bearing support. However, there are no published leakage calculation methodologies of these seals. Radial face contact seal leakage is determined by the gap clearance in the carbon seal ring split. In turn, the size gap clearance depends on the deformation of the seal assembly parts and from the engine operation. The article shows the leakage detection sequence in the intershaft radial face contact seal of the compressor support for take-off and cruising modes. Evaluated calculated leakage values (2.4 g/s at takeoff and 0.75 g/s at cruising) go with experience in designing seals.

  14. Clinical Outcomes following median to radial nerve transfers

    Science.gov (United States)

    Ray, Wilson Z.; Mackinnon, Susan E.

    2010-01-01

    Purpose In this study the authors evaluate the clinical outcomes in patients with radial nerve palsy who underwent nerve transfers utilizing redundant fascicles of median nerve (innervating the flexor digitorum superficialis and flexor carpi radialis muscles) to the posterior interosseous nerve and the nerve to the extensor carpi radialis brevis. Methods A retrospective review of the clinical records of 19 patients with radial nerve injuries who underwent nerve transfer procedures using the median nerve as a donor nerve were included. All patients were evaluated using the Medical Research Council (MRC) grading system. Results The mean age of patients was 41 years (range 17 – 78 years). All patients received at least 12 months of follow-up (20.3 ± 5.8 months). Surgery was performed at a mean of 5.7 ± 1.9 months post-injury. Post-operative functional evaluation was graded according to the following scale: grades MRC 0/5 - MRC 2/5 were considered poor outcomes, while MRC of 3/5 was a fair result, MRC grade 4/5 was a good result, and grade 4+/5 was considered an excellent outcome. Seventeen patients (89%) had a complete radial nerve palsy while two patients (11%) had intact wrist extension but no finger or thumb extension. Post-operatively all patients except one had good to excellent recovery of wrist extension. Twelve patients recovered good to excellent finger and thumb extension, two patients had fair recovery, five patients had a poor recovery. Conclusions The radial nerve is a commonly injured nerve, causing significant morbidity in affected patients. The median nerve provides a reliable source of donor nerve fascicles for radial nerve reinnervation. This transfer was first performed in 1999 and evolved over the subsequent decade. The important nuances of both surgical technique and motor re-education critical for to the success of this transfer have been identified and are discussed. PMID:21168979

  15. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Science.gov (United States)

    Thankappan, Krishnakumar; Trivedi, Nirav P.; Sharma, Mohit; Kuriakose, Moni A.; Iyer, Subramania

    2009-01-01

    A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome. PMID:19881028

  16. Free radial forearm adiposo-fascial flap for inferior maxillectomy defect reconstruction

    Directory of Open Access Journals (Sweden)

    Thankappan Krishnakumar

    2009-01-01

    Full Text Available A free radial forearm fascial flap has been described for intraoral reconstruction. Adiposo-fascial flap harvesting involves few technical modifications from the conventional radial forearm fascio-cutaneous free flap harvesting. We report a case of inferior maxillectomy defect reconstruction in a 42-year-old male with a free radial forearm adiposo-fascial flap with good aesthetic and functional outcome with minimal primary and donor site morbidity. The technique of raising the flap and closing the donor site needs to be meticulous in order to achieve good cosmetic and functional outcome.

  17. The radial distribution of plutonium in high burnup UO2 fuels

    International Nuclear Information System (INIS)

    Lassmann, K.; O'Carroll, C.; Laar, J. van de; Walker, C.T.

    1994-01-01

    A new model (TUBRNP) is described which predicts the radial power density distribution as a function of burnup (and hence the radial burnup profile as a function of time) together with the radial profile of uranium and plutonium isotopes. Comparisons between measurements and the predictions of the TUBRNP model are made on fuels with enrichments in the range 2.9 to 8.25% and with burnups between 21 000 and 64 000 MWd/t. It is shown to be in excellent agreement with experimental measurements and is a marked improvement on earlier versions. (orig.)

  18. Oculoauriculovertebral spectrum with radial anomaly in child.

    Science.gov (United States)

    Taksande, Amar; Vilhekar, Krishna

    2013-01-01

    Oculoauriculovertebral spectrum (OAVS) or Goldenhar syndrome is a wide spectrum of congenital anomalies that involves structures arising from the first and second branchial arches. It is characterized by a wide spectrum of symptoms and physical features. These abnormalities mainly involve the cheekbones, jaws, mouth, ears, eyes, or vertebrae. Other conditions with ear and/or radial involvement, such as, the Nager syndrome, Holt-Oram syndrome, Radial-renal syndrome, facioauriculoradial dysplasia, Fanconi anemia, and Vertebral, Anal atresia, Cardiac, Trachea, Esophageal, Renal, and Limb (VACTERL) association should be considered for differential diagnosis. Here we report a child who had facial asymmetry, microsomia, microtia, congenital facial nerve palsy, conductive hearing loss, skin tags, iris coloboma, and preaxial polydactyly.

  19. Oculoauriculovertebral spectrum with radial anomaly in child

    Directory of Open Access Journals (Sweden)

    Amar Taksande

    2013-01-01

    Full Text Available Oculoauriculovertebral spectrum (OAVS or Goldenhar syndrome is a wide spectrum of congenital anomalies that involves structures arising from the first and second branchial arches. It is characterized by a wide spectrum of symptoms and physical features. These abnormalities mainly involve the cheekbones, jaws, mouth, ears, eyes, or vertebrae. Other conditions with ear and/or radial involvement, such as, the Nager syndrome, Holt-Oram syndrome, Radial-renal syndrome, facioauriculoradial dysplasia, Fanconi anemia, and Vertebral, Anal atresia, Cardiac, Trachea, Esophageal, Renal, and Limb (VACTERL association should be considered for differential diagnosis. Here we report a child who had facial asymmetry, microsomia, microtia, congenital facial nerve palsy, conductive hearing loss, skin tags, iris coloboma, and preaxial polydactyly.

  20. WWER radial reflector modeling by diffusion codes

    International Nuclear Information System (INIS)

    Petkov, P. T.; Mittag, S.

    2005-01-01

    The two commonly used approaches to describe the WWER radial reflectors in diffusion codes, by albedo on the core-reflector boundary and by a ring of diffusive assembly size nodes, are discussed. The advantages and disadvantages of the first approach are presented first, then the Koebke's equivalence theory is outlined and its implementation for the WWER radial reflectors is discussed. Results for the WWER-1000 reactor are presented. Then the boundary conditions on the outer reflector boundary are discussed. The possibility to divide the library into fuel assembly and reflector parts and to generate each library by a separate code package is discussed. Finally, the homogenization errors for rodded assemblies are presented and discussed (Author)