WorldWideScience

Sample records for radial artery grafts

  1. Intraluminal milrinone for dilation of the radial artery graft.

    Science.gov (United States)

    García-Rinaldi, R; Soltero, E R; Carballido, J; Mojica, J

    1999-01-01

    There is renewed interest in the use of the radial artery as a conduit for coronary artery bypass surgery. The radial artery is, however, a very muscular artery, prone to vasospasm. Milrinone, a potent vasodilator, has demonstrated vasodilatory properties superior to those of papaverine. In this report, we describe our technique of radial artery harvesting and the adjunctive use of intraluminal milrinone as a vasodilator in the preparation of this conduit for coronary artery bypass grafting. We have used these techniques in 25 patients who have undergone coronary artery bypass grafting using the radial artery. No hand ischemic complications have been observed in this group. Intraluminal milrinone appears to dilate and relax the radial artery, rendering this large conduit spasm free and very easy to use. We recommend the skeletonization technique for radial artery harvesting and the use of intraluminal milrinone as a radial artery vasodilator in routine myocardial revascularization. PMID:10524740

  2. Long-term outcomes of internal carotid artery disease treated using radial artery graft

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Umeoka, Katsuya; Tateyama, Kojiro

    2009-01-01

    Complex internal carotid artery disease presents a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict occurrence of ischemic complications after internal carotid artery ligation. The present study concerns long-term clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2007, we performed radial artery grafting followed immediately by parent artery occlusion in 20 sides of 19 patients with complex internal carotid arteries disease with follow-up for more than 36 months (5 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative MRI and MR angiography (MRA) every year to assess graft patency, ischemic complications, and de novo aneurysm. Another 20 carotid aneurysms with visual disturbance were assessed concerning outcome. Among 13 patients with cranial nerve (III and VI) disturbances, all dysfunctions were improved in cases treated within 8 months of onset to operation. On the other hand, patients with second cranial nerve disturbances were not improved in cases treated after 4 months of onset. No long-term complications were discovered with MRI and MRA. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Long-term safety is satisfactory, with no delayed complications such as graft stenosis, ischemic complications or de novo aneurysm formations in follow-up periods of more than 3 years. Good clinical outcome of cranial nerve palsy was achieved in patients treated within 8 months of onset for cranial nerve (CN) III and VI, and 4 of CN II palsy. (author)

  3. Optimal management of radial artery grafts in CABG: Patient and target vessel selection and anti-spasm therapy.

    Science.gov (United States)

    Schwann, Thomas A; Gaudino, Mario; Baldawi, Mustafa; Tranbaugh, Robert; Schwann, Alexandra N; Habib, Robert H

    2018-05-01

    The current literature on radial artery grafting is reviewed focusing on the optimal deployment of radial artery grafts in coronary artery bypass surgery with specific attention to the selection of patients and target vessels for radial artery grafting. © 2018 Wiley Periodicals, Inc.

  4. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  5. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  6. Endoscopic versus open radial artery harvest and mammario-radial versus aorto-radial grafting in patients undergoing coronary artery bypass surgery

    DEFF Research Database (Denmark)

    Carranza, Christian L; Ballegaard, Martin; Werner, Mads U

    2014-01-01

    the postoperative complications will be registered, and we will evaluate muscular function, scar appearance, vascular supply to the hand, and the graft patency including the patency of the central radial artery anastomosis. A patency evaluation by multi-slice computer tomography will be done at one year...... to aorto-radial revascularisation techniques but this objective is exploratory. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01848886.Danish Ethics committee number: H-3-2012-116.Danish Data Protection Agency: 2007-58-0015/jr.n:30-0838....

  7. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  8. Utilização da artéria radial como segundo enxerto arterial em pacientes acima de 70 anos The use of the radial artery as the second choice for arterial graft in patients over 70 years of age

    Directory of Open Access Journals (Sweden)

    Joseph Fredric Whitaker

    2005-03-01

    Full Text Available OBJETIVO: Estudo retrospectivo para avaliar a morbi-mortalidade e a evolução hospitalar em pacientes com idade superior a 70 anos, submetidos à operação de revascularização do miocárdio com utilização da artéria radial como segundo enxerto arterial. MÉTODO: No período de agosto de 1994 a dezembro de 2002, foram realizadas 2487 cirurgias de revascularização do miocárdio no Instituto do Coração de Juiz de Fora. Dentre os pacientes operados, 476 tinham idade superior a 70 anos, sendo que em 36 (Grupo II foi utilizada a artéria radial como 2º enxerto arterial. O mesmo tipo de cirurgia foi realizado em 142 pacientes com idade inferior a 70 anos (Grupo I. Não foram incluídas neste estudo reoperações, cirurgias sem CEC ou com procedimentos associados. RESULTADOS: A média de idade do Grupo II foi 72,5 anos, a mortalidade hospitalar neste grupo de pacientes foi 6,0%, a incidência de complicações também foi baixa, comparável à observada no mesmo tipo de operação realizada em pacientes com idade inferior a 70 anos. CONCLUSÃO: Diante destes resultados, os autores acreditam que a artéria radial possa ser usada com segurança como 2º enxerto arterial em pacientes acima de 70 anos, criteriosamente selecionados, apesar do maior risco de co-morbidades associadas nesta faixa etária.OBJECTIVE: Retrospective study eveluating the morbid-mortality and hospital behaviour in patients over 70-years -od patients submitted to myocardial revascularization involving the radial artery as the second arterial graft. METHOD: During the period of August 1994 to December 2002, 2487 cases of myocardial revascularization were performed by the group of the Juiz de Fora Heart Institute, 476 of whom were 70 years of age or older and 36 (Group II received the radial artery as the second arterial graft. The same type of surgery was performed in 142 patients under 70-year-old (Group I. Reoperations, off-pump operations (OPCAB or associated procedures

  9. Comparação da perviedade entre artéria radial e veia safena em pacientes em pós-operatório de cirurgia de revascularização miocárdica com retorno dos sintomas Comparison of patency between radial artery and saphenous vein in a coronary artery bypass grafting post operative with return of the symptoms

    Directory of Open Access Journals (Sweden)

    Herbert Coelho Hortmann

    2010-06-01

    Full Text Available OBJETIVO: Comparar a perviedade da artéria radial e veia safena em pacientes com retorno dos sintomas após cirurgia de revascularização do miocárdio (CRVM. MÉTODOS: Estudo retrospectivo. No período de janeiro de 1998 a dezembro de 2005, foram realizadas 469 CRVMs com o uso da artéria radial dentre os enxertos, no Hospital Vera Cruz, em Belo Horizonte/MG. Destes, 94 pacientes apresentaram alterações isquêmicas no pós-operatório recente ou tardio e foram reestudados com cineangiocoronariografia. Os enxertos foram divididos em três grupos: artéria torácica interna (ATI, artéria radial (AR e veia safena (VS, e foram estratificados segundo a gravidade das lesões: sem lesão grave (OBJECTIVE: To compare the radial artery and saphenous vein's patency in patients with recurrence of symptoms in a coronary artery bypass grafting (CABG. METHODS: Retrospective study. From January 1998 to December 2005, 469 CABGs were performed using the radial artery as a graft, in Vera Cruz Hospital in Belo Horizonte/ MG. Among the patients who underwent those surgeries, 94 presented ischemic changes in early or late postoperative period, which led them to be re-evaluated by coronary angiography. The grafts were divided in three groups: internal thoracic artery (ITA, radial artery (RA and saphenous vein (SV, and they were stratified according to the severity of injury: uninjured or patent (< 70%, severe obstruction (70 to 99% and occlusion. RESULTS: For the 94 patients in the study, 86 grafts of ITA, 94 of RA and 111 of SV were used. For the 86 ITA grafts, 73 (84.88% were found patent. For the 94 RA grafts, 55 (58.51% were found patent, and for the 111 SV grafts, 73 (65.76% were uninjured. A statistically significant difference (P= 0.001 was found between RA and SV grafts, with a higher patency found for VS graft. For the RA grafts, women presented a worse result concerning the RA patency (65.7% and 40.7%, with P = 0.006. Concerning coronary

  10. Sharp Dissection versus Electrocautery for Radial Artery Harvesting

    Science.gov (United States)

    Marzban, Mehrab; Arya, Reza; Mandegar, Mohammad Hossein; Karimi, Abbas Ali; Abbasi, Kiomars; Movahed, Namvar; Abbasi, Seyed Hesameddin

    2006-01-01

    Radial arteries have been increasingly used during the last decade as conduits for coronary artery revascularization. Although various harvesting techniques have been described, there has been little comparative study of arterial damage and patency. A radial artery graft was used in 44 consecutive patients, who were randomly divided into 2 groups. In the 1st group, the radial artery was harvested by sharp dissection and in the 2nd, by electrocautery. These groups were compared with regard to radial artery free flow, harvest time, number of clips used, complications, and endothelial damage. Radial artery free flow before and after intraluminal administration of papaverine was significantly greater in the electrocautery group (84.3 ± 50.7 mL/min and 109.7 ± 68.5 mL/min) than in the sharp-dissection group (52.9 ± 18.3 mL/min and 69.6 ± 28.2 mL/ min) (P =0.003). Harvesting time by electrocautery was significantly shorter (25.4 ± 4.3 min vs 34.4 ± 5.9 min) (P =0.0001). Electrocautery consumed an average of 9.76 clips, versus 22.45 clips consumed by sharp dissection. The 2 groups were not different regarding postoperative complications, except for 3 cases of temporary paresthesia of the thumb in the electrocautery group; histopathologic examination found no endothelial damage. We conclude that radial artery harvesting by electrocautery is faster and more economical than harvesting by sharp dissection and is associated with better intraoperative flow and good preservation of endothelial integrity. PMID:16572861

  11. Evaluation of early coronary graft patency after coronary artery bypass graft surgery using multislice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Raissi Kamal

    2009-12-01

    Full Text Available Abstract Background Coronary artery bypass graft (CABG surgery is the standard of care in the treatment of advanced coronary artery disease, and its long-term results are affected by the failure of bypass grafts. The aim of the present study was to evaluate the early patency rate in coronary bypass grafts. Methods A total of 107 consecutive patients who underwent CABG were included in this study. Early graft patency was evaluated via computed tomography (CT angiography in the first week after surgery. Results There were a total of 366 grafts, comprised of 250 venous grafts and 116 arterial grafts. Multi-slice CT detected acute graft occlusions in 32 (8.7% of all the grafts, including 26 (10% of the 250 venous grafts and 6 (5% of the 116 arterial grafts. The patency rates obtained were 97.3% for the left internal mammary (IMA grafts, 50% for the radial artery grafts, and 50% for the right IMA grafts. Additionally, 107 (96.4% grafts to the left anterior descending artery (LAD were classified as patent, whereas 1 (30% of the 3 grafts in the left circumflex (LCX region and 1 (50% of the 2 grafts in the right coronary artery (RCA territory were found to be occluded. In the venous category, 8 (13.7% of the 58 grafts to LAD were found to be occluded. In the LCX region, 9 (8.5% of the 106 grafts were classified as occluded, while the remaining 97 (91.5% grafts were patent. The venous grafts to RCA were occluded in 9 (10.4% of the 86 grafts. Amongst the multiple preoperative, intraoperative, and postoperative factors, pump time was significantly longer in the patients with occluded grafts than in those with patent grafts (P = 0.04. Conclusion The IMA grafts had the highest early patency rate amongst the coronary bypass grafts. However, the other arterial grafts were associated with a high rate of acute occlusions.

  12. The relationship between total arterial revascularization and blood transfusion following coronary artery bypass grafting.

    Science.gov (United States)

    Djordjevic, Jasmina; Ngaage, Dumbor L

    2015-05-01

    Blood transfusion adversely affects the outcome of coronary artery bypass grafting (CABG), yet blood transfusion after CABG is still common. Total arterial revascularisation (TAR) is increasingly used in current practice but its impact on postoperative blood transfusion is not known. We reviewed the cardiothoracic and blood bank databases and collected data for isolated primary CABG patients from July 2007 to June 2012, excluding patients who had a single graft (n = 148). Perioperative variables of TAR patients (n = 745) were compared with patients who had one or more venous grafts (SVG, n = 1,761) for first-time isolated CABG. The conduits used in TAR patients were predominantly left internal thoracic and radial arteries. Matched group comparison of TAR and SVG patients was performed. The association of TAR with blood transfusion was investigated using multivariate and matched analysis. Of 2,506 patients, the 745 (29.7 %) that had TAR were generally younger, with less complex coronary artery disease and less often diabetic. After correcting for these by 1:1 matching, the mean chest tube drainage and rates of blood transfusion remained significantly lower (p transfused in TAR patients. By multivariate analysis, TAR had an independent effect on reducing blood transfusion after CABG [odds ratio (OR) 0.67, 95 % confidence interval (CI) 0.47-0.97, p = .03]. TAR achieved predominantly with left internal thoracic and radial arteries substantially reduced blood transfusion rates after primary CABG. Further studies are warranted.

  13. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  14. Radial Artery as a Coronary Artery Bypass Conduit: 20-Year Results.

    Science.gov (United States)

    Gaudino, Mario; Tondi, Paolo; Benedetto, Umberto; Milazzo, Valentina; Flore, Roberto; Glieca, Franco; Ponziani, Francesca Romana; Luciani, Nicola; Girardi, Leonard N; Crea, Filippo; Massetti, Massimo

    2016-08-09

    There is a lack of evidence for the choice of the second conduit in coronary surgery. The radial artery (RA) is a possible option, but few data on very-long-term outcomes exist. This study describes 20-year results of RA grafts used for coronary artery bypass grafting and the effects of RA removal on forearm circulation. We report the results of the prospective 20-year follow-up of the first 100 consecutive patients who received the RA as a coronary bypass conduit at our institution. Follow-up was 100% complete. There were 64 deaths, 23 (35.9%) from cardiovascular causes. Kaplan-Meier 20-year survival was 31%. Of the 36 survivors, 33 (91.6%) underwent RA graft control at a mean of 19.0 ± 2.5 years after surgery. The RA was found to be patent in 24 cases (84.8% patency). In the overall population, probability of graft failure at 20 years was 19.0 ± 0.2% for the left internal thoracic artery (ITA), 25.0 ± 0.2% for the RA, and 55.0 ± 0.2% for the saphenous vein (p = 0.002 for RA vs. saphenous vein, 0.11 for RA vs. ITA, and p 90%, but not location of distal anastomosis, significantly influenced long-term RA graft patency. No patients reported hand or forearm symptoms. The ulnar artery diameter was increased in the operated arm (2.44 ± 0.43 mm vs. 2.01 ± 0.47 mm; p 90% stenosis. RA harvesting does not lead to hand or forearm symptoms, even at a very-long-term follow-up. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  15. Incremental Value of Increasing Number of Arterial Grafts: The Effect of Diabetes Mellitus.

    Science.gov (United States)

    Schwann, Thomas A; El Hage Sleiman, Abdul Karim M; Yammine, Maroun B; Tranbaugh, Robert F; Engoren, Milo; Bonnell, Mark R; Habib, Robert H

    2018-06-01

    Multiarterial coronary grafting with two arterial grafts leads to improved survival compared with conventional single artery based on left internal thoracic artery to left anterior descending artery and saphenous vein grafts. We investigated whether extending arterial grafting to three or more arterial grafts further improves survival, and whether such a benefit is modified by diabetes mellitus. We analyzed 15-year coronary artery bypass graft surgery mortality data in 11,931 patients (age 64.3 ± 10.5 years; 3,484 women [29.2%]; 4,377 [36.7%] with diabetes mellitus) derived from three US institutions (1994 to 2011). All underwent primary isolated left internal thoracic artery to left anterior descending artery grafting with at least two grafts: one artery (n = 6,782; 56.9%); two arteries (n = 3,678; 30.8%); or three or more arteries (n = 1,471; 12.3%). Long-term survival was estimated by Kaplan-Meier methods. Propensity score matching and comprehensive covariate adjustment (Cox regression) were used to derive long-term risk-adjusted hazard ratio (HR) with 95% confidence interval (CI) for increasing number of arterial grafts in the overall cohort and for diabetes and no-diabetes cohorts. Radial artery (94%) and right internal thoracic artery (6%) were used as additional arterial grafts. Multivariate analysis in all patients showed that diabetes was associated with decreased survival (HR 1.43, 95% CI: 1.34 to 53), whereas increasing number of arterial grafts was associated with decreased mortality (one artery HR 1.0 [reference]; two arteries HR 0.87, 95% CI: 0.80 to 0.95; and three arteries HR 0.83, 95% CI: 0.72 to 0.95). Pairwise comparisons also showed an incremental benefit of additional arterial grafts: two arteries versus one artery, HR 0.89 (95% CI: 0.80 to 0.98); and three arteries versus one artery, HR 0.80 (95% CI: 0.68 to 0.94). A three-artery versus two-artery survival advantage trend was also noted, but was not significant in either the overall study

  16. A mechanical argument for the differential performance of coronary artery grafts.

    Science.gov (United States)

    Prim, David A; Zhou, Boran; Hartstone-Rose, Adam; Uline, Mark J; Shazly, Tarek; Eberth, John F

    2016-02-01

    Coronary artery bypass grafting (CABG) acutely disturbs the homeostatic state of the transplanted vessel making retention of graft patency dependent on chronic remodeling processes. The time course and extent to which remodeling restores vessel homeostasis will depend, in part, on the nature and magnitude of the mechanical disturbances induced upon transplantation. In this investigation, biaxial mechanical testing and histology were performed on the porcine left anterior descending artery (LAD) and analogs of common autografts, including the internal thoracic artery (ITA), radial artery (RA), great saphenous vein (GSV) and lateral saphenous vein (LSV). Experimental data were used to quantify the parameters of a structure-based constitutive model enabling prediction of the acute vessel mechanical response pre-transplantation and under coronary loading conditions. A novel metric Ξ was developed to quantify mechanical differences between each graft vessel in situ and the LAD in situ, while a second metric Ω compares the graft vessels in situ to their state under coronary loading. The relative values of these metrics among candidate autograft sources are consistent with vessel-specific variations in CABG clinical success rates with the ITA as the superior and GSV the inferior graft choices based on mechanical performance. This approach can be used to evaluate other candidate tissues for grafting or to aid in the development of synthetic and tissue engineered alternatives. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  18. Multiple arterial grafts in coronary artery bypass grafting, Sohag University Hospital's initial experience

    Directory of Open Access Journals (Sweden)

    A.A.A. Elsayed

    2017-12-01

    Conclusions: Using multiple arterial grafts did not add a significant risk or time to the classic CABG. With accumulating evidence about better patency rate in arterial grafts, MAR is recommended especially in younger patients undergoing CABG.

  19. Anomalies of radial and ulnar arteries

    Directory of Open Access Journals (Sweden)

    Rajani Singh

    Full Text Available Abstract During dissection conducted in an anatomy department of the right upper limb of the cadaver of a 70-year-old male, both origin and course of the radial and ulnar arteries were found to be anomalous. After descending 5.5 cm from the lower border of the teres major, the brachial artery anomalously bifurcated into a radial artery medially and an ulnar artery laterally. In the arm, the ulnar artery lay lateral to the median nerve. It followed a normal course in the forearm. The radial artery was medial to the median nerve in the arm and then, at the level of the medial epicondyle, it crossed from the medial to the lateral side of the forearm, superficial to the flexor muscles. The course of the radial artery was superficial and tortuous throughout the arm and forearm. The variations of radial and ulnar arteries described above were associated with anomalous formation and course of the median nerve in the arm. Knowledge of neurovascular anomalies are important for vascular surgeons and radiologists.

  20. Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass.

    Science.gov (United States)

    Suematsu, Y; Takamoto, S; Ohtsuka, T

    2001-12-01

    No accepted approach exists for the intraoperative evaluation of the quality of coronary arteries and the technical adequacy of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass. We assessed the accuracy of high-frequency epicardial echocardiography and power Doppler imaging in evaluating coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass. To validate measurements of coronary arteries and graft anastomoses by high-frequency epicardial echocardiography and power Doppler imaging, we compared luminal diameters determined by these methods with diameters determined histologically in a study of off-pump coronary artery bypass grafting in 20 dogs. Technical errors were deliberately created in 10 grafts (stenosis group). The results of these animal validation studies showed that the maximum luminal diameters of coronary arteries and graft anastomoses measured by high-frequency epicardial echocardiography (HEE) and power Doppler imaging (PDI) correlated well with the histologic measurements: HEE = 1.027 x Histologic measurements + 0.005 (P anastomoses were examined intraoperatively by high-frequency epicardial echocardiography and power Doppler imaging, and luminal diameters determined by power Doppler imaging were compared with those determined by postoperative coronary angiography. The results demonstrated that graft anastomosis by power Doppler imaging correlated well with the angiographic measurements: PDI = 1.018 x Angiographic measurements - 0.106 (P anastomoses and can detect technical errors and inadequacies during coronary artery bypass grafting without cardiopulmonary bypass.

  1. Vasodilatory effect and endothelial integrity in papaverine- and milrinone-treated human radial arteries.

    Science.gov (United States)

    Rudzinski, P; Wegrzyn, P; Lis, G J; Piatek, J; Konstanty-Kalandyk, J; Nosalski, R; Mikolajczyk, T; Jasinska, M; Pyka-Fosciak, G; Guzik, T; Litwin, J A; Korbut, R; Sadowski, J

    2013-02-01

    Prevention of the vasospasm is an important aspect of coronary artery bypass grafting (CABG) with the use of radial artery (RA) as the conduit. We compared the effect of two phosphodiesterase inhibitors papaverine and milrinone on vasodilation and endothelial integrity of human RA segments harvested from 20 CABG patients. Vasodilatory effect of the drugs were assessed by organ bath technique in RA rings precontracted with KCl and phenylephrine. Endothelial integrity was evaluated by CD34 immunofluorescence in frozen sections. Vasorelaxation induced by papaverine was significantly greater as compared to that induced by milrinone (90.47% ± 10.16% vs. 78.98% ± 19.56%, pmilrinone in the preservation of endothelial integrity (75.3% ± 12.9% vs. 51.8% ± 18.0%, pmilrinone for prevention of vasospasm in radial artery conduits used for CABG.

  2. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  3. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  4. Coronary artery bypass grafts: assessment of graft patency and native coronary artery lesions using 16-slice MDCT

    Energy Technology Data Exchange (ETDEWEB)

    Stauder, Norbert I.; Drosch, Tanja; Claussen, Claus D.; Kopp, Andreas F. [Eberhard-Karls-University, Department of Diagnostic Radiology, Tuebingen (Germany); Kuettner, Axel [Friedrich-Alexander-University, Department of Diagnostic Radiology, Erlangen (Germany); Schroeder, Stephen; Beck, Torsten [Eberhard-Karls-University, Department of Internal Medicine, Division Cardiology, Tuebingen (Germany); Stauder, Heidrun [Eberhard-Karls-University, Department of Thoracic and Cardiovascular Surgery, Tuebingen (Germany); Blumenstock, Gunnar [Eberhard-Karls-University, Department of Medical Information Processing, Tuebingen (Germany)

    2006-11-15

    The objective of this study was to evaluate the accuracy of electrocardiography (ECG)-gated 16-slice multidetector-row computed tomography (MDCT) in detection of stenosis of bypass grafts and native coronary arteries in patients who have undergone coronary artery bypass grafting (CABG). ECG-gated contrast-enhanced MDCT using 12 x 0.75-mm collimation was performed in 20 patients with recurrent angina 4.75 years after undergoing CABG. A total of 50 grafts, 16 arterial and 34 venous, were examined. All graft and coronary segments were evaluated for stenosis in comparison with conventional coronary angiography (CCA). Among the 80 arterial graft segments, 62 could be assessed (77.5%). Sensitivity, specificity, and positive and negative predictive values for stenosis were 96.2%, 97.2%, 96.2%, and 97.2%, respectively. In a total of 180 venous graft segments, 167 could be assessed. Sensitivity, specificity, and positive and negative predictive values for stenosis were 98.5%, 93.9%, 91.8%, and 98.9%, respectively. MDCT could assess 179 of 260 native coronary artery segments (68.8%).Sensitivity, specificity, and positive and negative predictive values for stenosis were 92.1%, 76.9%, 87.5%, and 84.7%, respectively. Sixteen-slice MDCT provides excellent image quality and diagnostic accuracy in detection of graft and coronary artery lesions in patients with suspected graft dysfunction. (orig.)

  5. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  6. Vascularised Fibular Graft for a Radial Defect following Tumour ...

    African Journals Online (AJOL)

    HP

    The mass was located on the radial aspect of the distal right ... modification, internal or external fixation with bone grafting, structural grafts of ... Our index case report demonstrates that free vascularized fibular graft transfer is a feasible option ... structural support, the potential for graft hypertrophy, relative resistance to ...

  7. Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomography

    Science.gov (United States)

    Brazio, Philip S.; Laird, Patrick C.; Xu, Chenyang; Gu, Junyan; Burris, Nicholas S.; Brown, Emile N.; Kon, Zachary N.; Poston, Robert S.

    2009-01-01

    Objective Vasospasm is the primary obstacle to widespread adoption of the radial artery as a conduit in coronary artery bypass grafting. We used optical coherence tomography, a catheter-based intravascular imaging modality, to measure the degree of radial artery spasm induced by means of harvest with electrocautery or a harmonic scalpel in patients undergoing coronary artery bypass grafting. Methods Radial arteries were harvested from 44 consecutive patients with a harmonic scalpel (n = 15) or electrocautery (n = 29). Vessels were imaged before harvesting and after removal from the arm, with saphenous vein tracts serving as internal controls. Optical coherence tomographic findings for the degree of harvesting-induced injury were validated against histologic measures. Results Optical coherence tomographic measures of endovascular dimensions and injury correlated strongly with histologic findings. Mean luminal volume, a measure of vasospasm, decreased significantly less after harvesting with a harmonic scalpel (9% ± 7%) than with electrocautery (35% ± 6%, P = .015). Completely intact intima was present in 11 (73%) of 15 radial arteries harvested with a harmonic scalpel (73%) compared with 9 of 29 arteries harvested by means of electrocautery (31%, P = .011). Intraoperative flow measurements and patency rates at 5 days postoperatively were not significantly different among groups. Conclusions Optical coherence tomography provides a level of speed and accuracy for quantifying endothelial injury and vasospasm that has not been described for any other modality, suggesting potential as an intraoperative quality assurance tool. Our optical coherence tomographic findings suggest that the harmonic scalpel induces less spasm and intimal injury compared with electrocautery. PMID:19026820

  8. Worldwide Trends in Multi-arterial Coronary Artery Bypass Grafting Surgery 2004-2014: A Tale of 2 Continents.

    Science.gov (United States)

    Schwann, Thomas A; Tatoulis, James; Puskas, John; Bonnell, Mark; Taggart, David; Kurlansky, Paul; Jacobs, Jeffery P; Thourani, Vinod H; O'Brien, Sean; Wallace, Amelia; Engoren, Milo C; Tranbaugh, Robert F; Habib, Robert H

    2017-01-01

    Recent evidence shows that multi-arterial coronary artery bypass grafting (MABG) based on bilateral internal thoracic (BITA) or left internal thoracic (LITA) and radial artery (RA) improves long-term outcomes compared with single arterial coronary artery bypass grafting (SABG) (LITA + saphenous vein graft). How this evidence affected the worldwide use of MABG, if at all, is not well defined. Accordingly, we report 10-year temporal trends of MABG utilization from 2 continents. A study population of 1,683,434 non-emergent, primary, isolated LITA-based coronary artery bypass grafting (CABG) (≥2 grafts) patients was derived from the Society of Thoracic Surgeons (STS) (1,307,528 (79.5%) of 1,644,388 isolated CABG; total 1179 centers) and the Australia New Zealand Cardiothoracic (ANZ) Databases (34,213 (87%) of 39,046 isolated CABG; 24 centers) between 2004 and 2014. Patients were excluded based on the following: (1) no LITA, (2) if arterial grafts were other than RA or ITA, or (3) if grafting data were missing. The 3 MABG groups were LITA + RA, BITA, and BITA + RA, each with or without supplemental vein grafts. Grafting trends and their associated patient demographics were analyzed. SABG (89.3% STS, 51.4% ANZ) was the most common grafting strategy. MABG was most frequently accomplished by LITA + RA: (STS: 6.1%; ANZ: 42.6%), followed by BITA: (STS: 4.1%; ANZ: 4.3%), while ≥3 (BITA + RA) was rare in the STS (0.5%), but more common in ANZ (5.9%). In the STS, between 2004 and 2014, SABG rates systematically increased from 85.2% to 91.7%, BITA grafting was essentially unchanged from 3.6% to 4.3%, while RA use decreased systematically from 10.5% to 3.7%. In the ANZ, SABG rates increased from 17.3% to 51.4%, BITA grafting decreased from 6.3% to 3.6%, while RA grafting decreased from 65.8% to 39.0%. Compared with SABG patients, BITA patients were younger (STS: median age 59 vs 66, P 30 kg/m 2 ) in STS (37% vs 42%, P < 0.001), more obese in ANZ

  9. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  10. Mid-term results of off-pump coronary artery bypass grafting assessed by multi-slice computed tomography

    International Nuclear Information System (INIS)

    Yoshida, Seijiro; Nitta, Yoshio; Oda, Katsuhiko

    2004-01-01

    Off-pump coronary artery bypass (OPCAB) has recently increased in popularity, but the long-term results are still unknown. We evaluated the mid-term results of OPCAB surgery using multi-slice computed tomography (MSCT), which is a non-invasive postoperative evaluation method. Thirty-one consecutive patients who underwent OPCAB surgery at least 2 years prior to the study were selected. The age was 50 to 79 years (66.9±6.5) and the ratio of men to women was 26:5. Coronary angiography was performed in all patients at 2 weeks postoperatively. The follow-up was complete, and mean follow-up was 30.9 months. There were no hospital deaths and 1 non-cardiac late death. The graft patency rate in coronary angiography was left internal thoracic artery (LITA) 30/30 (100%), right internal thoracic artery (RITA) 2/2 (100%), radial artery (RA) 14/15 (93%), saphenous vein graft (SVG) 15/17 (88%). No graft became occluded on MSCT study and all patients have been angina-free during the follow-up period. We suggest that OPCAB is feasible in most patients with good patency and low mortality. MSCT is an effective follow up method for the morphological findings and noninvasive quantitative evaluation of the bypass grafts. (author)

  11. Anomalous Medial Branch of Radial Artery: A Rare Variant

    Directory of Open Access Journals (Sweden)

    Surbhi Wadhwa

    2016-10-01

    Full Text Available Radial artery is an important consistent vessel of the upper limb. It is a useful vascular access site for coronary procedures and its reliable anatomy has resulted in an elevation of radial forearm flaps for reconstructive surgeries of head and neck. Technical failures, in both the procedures, are mainly due to anatomical variations, such as radial loops, ectopic radial arteries or tortuosity in the vessel. We present a rare and a unique anomalous medial branch of the radial artery spiraling around the flexor carpi radialis muscle in the forearm with a high rising superficial palmar branch of radial artery. Developmentally it probably is a remanent of the normal pattern of capillary vessel maintenance and regression. Such a case is of importance for reconstructive surgeons and coronary interventionists, especially in view of its unique medial and deep course.

  12. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    Science.gov (United States)

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  13. Impact of top end anastomosis design on patency and flow stability in coronary artery bypass grafting.

    Science.gov (United States)

    Koyama, Sachi; Kitamura, Tadashi; Itatani, Keiichi; Yamamoto, Tadashi; Miyazaki, Shohei; Oka, Norihiko; Nakashima, Kouki; Horai, Tetsuya; Ono, Minoru; Miyaji, Kagami

    2016-05-01

    For coronary artery bypass grafting (CABG), free grafts such as a saphenous vein or radial artery are often used for grafts to the lateral and posterior walls. However, the relationship between top-end anastomosis design and long-term patency remains unknown. Because coronary artery blood flow is dominant during diastole, top-end anastomosis may work better if the graft is directed towards the apex, whereas the shortest graft pathway appears to be most efficient. Using computational fluid dynamic models, we evaluated the hemodynamic variables that were affected by the angle of the top-end anastomosis. We created three-dimensional geometries of the aortic root with coronary arteries that involved 75 % stenosis in the obtuse marginal and postero-lateral branches. Two bypass models under vasodilator administration were created: in a"Model A", the top-end anastomosis is parallel to the long axis of the ascending aorta and the graft passed over the conus directed towards the apex; in a "Model B", the top-end anastomosis is directed toward the shortest pathway, and form near the right angles to the long axis of the ascending aorta. Wall shear stress (WSS) and its fluctuation, an oscillatory shear index (OSI) were evaluated to predict fibrosis progression at the anastomosis site and graft flow. Graft flow was 197.3 ml/min and 207.3 ml/min in the "Model A" and "Model B", respectively. The minimal WSS value inside the graft with the "Model A" and "Model B" was 0.53 Pa and 4.09 Pa, respectively, and the OSI value was 0.46 and 0.04, respectively. The top-end anastomosis of a free graft should be directed vertically towards the aorta to achieve the shortest graft pathway to maintain a high graft flow rate and to avoid the risks of endothelial fibrosis and plaque progression over the long-term after CABG.

  14. Evaluation of coronary artery bypass grafts with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okamura, Yoshitaka; Yamada, Yasuyuki; Mochizuki, Yoshihiko; Iida, Hiroshi; Mori, Hideaki; Sugita, You-ichi; Shimada, Kou-ichirou

    1997-01-01

    Currently, the efficacy of magnetic resonance imaging (MRI) for evaluating coronary artery disease has been reported. In this study, we have evaluated the usefulness and the problems of MRI for evaluating the patency of coronary artery bypass grafts. Thirty-five patients who received coronary artery bypass grafting (CABG) were evaluated by using MRI for determining the graft patency compared with conventional coronary angiography. There were 30 men and 5 women. The mean age was 61.2 years (range 45 to 75). The 35 patients had a total of 92 grafts (28 internal thoracic artery, 7 gastroepiploic artery and 57 saphenous vein grafts). Magnetic resonance coronary angiogram (MRCA) was performed with SIGNA HORIZON 1.5 T (GE Inc.) by using 2D-FASTCARD sequence. All patients underwent imaging in the transverse and coronal planes, most had imaging in the sagittal plane, and a few had in the oblique plane. By using MRCA, 82 of 90 grafts were diagnosed correctly as patent, and 1 of 2 grafts were diagnosed correctly as occluded. Thirty-four of 40 LAD grafts (85%), 20 of 22 RCA grafts (91%) and 29 of 30 Cx grafts (97%) were correctly evaluated. The efficacy of MRCA for evaluating the patency of coronary artery bypass grafts was recognized. But the sternal wire (stainless steel) and hemoclip interfere with the interpretation and reduce the sensitivity. Higher sensitivity may be obtained by changing the material of the sternal wires and hemoclips at coronary surgery. (author)

  15. Balloon expandable intraluminal grafting of normal and abnormal renal arteries: Experimental study

    International Nuclear Information System (INIS)

    Palmaz, J.C.; Hayashi, H.; Schatz, R.; Hunter, G.; Tio, F.O.; Garcia, O.

    1986-01-01

    Balloon expandable intraluminal grafts were placed in renal arteries of eight adult dogs and 11 minipigs. The renal arteries were normal in the dogs before graft placement. Two grafts were placed in primary division branches and the rest in the main renal artery. Experimental renal artery stenosis was created in the minipigs by subocclusive ligature of the renal artery with absorbable suture material. Six months later significant renal artery stenoses developed in six pigs and were corrected by graft placement. In the remaining pigs grafts were placed in the opposite normal renal artery because the stenosis caused a small, shrunken kidney in two, and severe spasm or anatomic variations prevented graft placement in three. All grafts remained patent on angiographic and pathologic examinations to a maximum follow-up to 24 weeks

  16. Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Yaseen, R.; Memon, H.

    2008-01-01

    To assess the effectiveness of femoral and radial arterial lines on the correlation of peripheral and central mean arterial blood pressure in children after discontinuation of cardiopulmonary bypass. Fifty children scheduled for cardiac surgery with cardiopulmonary bypass were included in the study. After approval from the hospital ethics committee and informed consent. 50 children undergoing cardiac surgical procedures with cardiopulmonary bypass were randomly assigned to two different groups. In Group- A (RAP, n-2) a radial arterial line and in Group-B (FAP, n-25) a femoral arterial line was used to monitor the blood pressure. Simultaneous mean peripheral arterial pressure and mean central aortic pressure were recorded before cardiopulmonary bypass and 5 mins after separation from the cardiopulmonary bypass. The correlation of mean peripheral arterial pressure (radial and femoral) versus mean aortic pressure were compared. The data was recorded as Mean +- SD and P-value. The ages of children ranged from 4-12 years and their weight from 14.1-28.5 kg. In all of them following cardiopulmonary bypass, aortic pressure correlates better with femoral arterial pressure (p<0.001). The radial arterial line readings under estimated central aortic pressure when compared to femoral arterial line readings. Aortic pressure readings correlate better with femoral arterial pressure than radial arterial pressure in children. (author)

  17. Randomized comparison of the clinical outcome of single versus multiple arterial grafts: the ROMA trial-rationale and study protocol.

    Science.gov (United States)

    Gaudino, Mario; Alexander, John H; Bakaeen, Faisal G; Ballman, Karla; Barili, Fabio; Calafiore, Antonio Maria; Davierwala, Piroze; Goldman, Steven; Kappetein, Peter; Lorusso, Roberto; Mylotte, Darren; Pagano, Domenico; Ruel, Marc; Schwann, Thomas; Suma, Hisayoshi; Taggart, David P; Tranbaugh, Robert F; Fremes, Stephen

    2017-12-01

    The primary hypothesis of the ROMA trial is that in patients undergoing primary isolated non-emergent coronary artery bypass grafting, the use of 2 or more arterial grafts compared with a single arterial graft (SAG) is associated with a reduction in the composite outcome of death from any cause, any stroke, post-discharge myocardial infarction and/or repeat revascularization. The secondary hypothesis is that in these patients, the use of 2 or more arterial grafts compared with a SAG is associated with improved survival. The ROMA trial is a prospective, unblinded, randomized event-driven multicentre trial comprising at least 4300 subjects. Patients younger than 70 years with left main and/or multivessel disease will be randomized to a SAG or multiple arterial grafts to the left coronary system in a 1:1 fashion. Permuted block randomization stratified by the centre and the type of second arterial graft will be used. The primary outcome will be a composite of death from any cause, any stroke, post-discharge myocardial infarction and/or repeat revascularization. The secondary outcome will be all-cause mortality. The primary safety outcome will be a composite of death from any cause, any stroke and any myocardial infarction. In all patients, 1 internal thoracic artery will be anastomosed to the left anterior descending coronary artery. For patients randomized to the SAG group, saphenous vein grafts will be used for all non-left anterior descending target vessels. For patients randomized to the multiple arterial graft group, the main target vessel of the lateral wall will be grafted with either a radial artery or a second internal thoracic artery. Additional grafts for the multiple arterial graft group can be saphenous veins or supplemental arterial conduits. To detect a 20% relative reduction in the primary outcome, with 90% power at 5% alpha and assuming a time-to-event analysis, the sample size must include 845 events (and 3650 patients). To detect a 20% relative

  18. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  19. Seguimento a longo prazo de pacientes submetidos à revascularização do miocárdio com uso exclusivo de enxertos arteriais Long-term follow-up of patients undergone coronary artery bypass grafting with exclusive use of arterial grafts

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Abdouni

    2008-12-01

    Full Text Available OBJETIVO: Avaliar os resultados a longo prazo da cirurgia de revascularização do miocárdio com o uso exclusivo de enxertos arteriais em pacientes com doença coronariana triarterial. MÉTODOS: Avaliamos 136 pacientes submetidos a cirurgia de revascularização do miocárdio isolada, no período janeiro de 1995 e dezembro de 1997. Utilizaram-se 353 enxertos para revascularizar 449 artérias (média: 3,30 por paciente. Foram utilizadas a artéria torácica interna esquerda (99,2%, artéria torácica interna direita (56,6%, artéria radial (87,5%, artéria gastroepiplóica direita (20,5% e uma artéria epigástrica inferior. Setenta e seis (55,8% pacientes receberam enxertos compostos (em "Y" e 66 (48,5% receberam anastomoses seqüenciais. RESULTADOS: A mortalidade hospitalar foi de 4,4%. No seguimento a longo prazo, (9,5 a 12,8 anos, 82,1% dos pacientes não apresentaram nenhum evento cardíaco. Vinte (17,9% pacientes necessitaram de reinternação por eventos cardiovasculares; 15 com angina e cinco com infarto agudo do miocárdio, sendo que três apresentaram insuficiência cardíaca associada. Oito (7,1% pacientes necessitaram de reintervenção por doença coronariana, sendo um reoperado e os demais submetidos a angioplastia com stent. A probabilidade estimada livre de eventos cardíacos foi de 98,2%, 95,4% e 84,2% em 1, 5 e 10 anos, respectivamente. Ocorreram 16 (14,2% óbitos tardios, sendo quatro deles (3,6% de causa cardíaca. Sobrevida actuarial em 12,8 anos por todas as causas foi de 85% neste grupo. CONCLUSÃO: Revascularização do miocárdio com o uso exclusivo de enxertos arteriais em pacientes com doença coronariana triarterial é um procedimento seguro, com bons resultados a longo prazo.OBJECTIVE: To evaluate the long-term results of the coronary artery bypass grafting with exclusive use of arterial grafts for patients with triple vessel disease. METHODS: We evaluated 136 patients who underwent isolated coronary artery bypass

  20. Does grafting coronary arteries with only moderate stenosis affect long-term mortality?

    Science.gov (United States)

    Sabik, Joseph F.; Olivares, Gabriel; Raza, Sajjad; Lytle, Bruce W.; Houghtaling, Penny L.; Blackstone, Eugene H.

    2016-01-01

    Objective Stenting coronary arteries with non–ischemia-producing moderate stenosis leads to worse outcomes than leaving them unstented. We sought to determine whether grafting coronary arteries with angiographically moderate stenosis is associated with worse long-term survival than leaving them ungrafted. Methods From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 8531 had a single coronary artery with moderate (50%-69%) stenosis, bypassed in 6598 (77%) and not bypassed in 1933 (23%). These arteries were grafted with internal thoracic arteries (ITAs) in 1806 patients (27%) and with saphenous veins (SVs) in 4625 (70%). Mean follow-up for all-cause mortality was 13.0 ± 9.7 years. Results Survival was similar for patients with and without a graft to the moderately stenosed coronary artery (P = .3): 97%, 76%, 43%, and 18% at 1, 10, 20, and 30 years among patients receiving no graft; 97%, 74%, 41%, and 18% among those receiving an SV graft; and 98%, 82%, 51%, and 23% among those receiving an ITA graft. After adjusting for patient characteristics, SV grafting versus nongrafting of moderately stenosed coronary arteries was associated with similar long-term mortality (P = .2), whereas ITA grafting was associated with 22% lower long-term mortality (hazard ratio 0.78; 68% confidence interval 0.75–0.82; P<.0001). Conclusions Grafting coronary arteries with angiographically moderate stenosis is not harmful. Instead, ITA grafting of such coronary arteries is associated with lower long-term mortality. Thus, after placing the first ITA to the left anterior descending, the second ITA should be placed to the second most important coronary artery, even if it is moderately stenosed. PMID:26611750

  1. Dopexamine increases internal mammary artery blood flow following coronary artery bypass grafting.

    LENUS (Irish Health Repository)

    Flynn, Michael J

    2012-02-03

    OBJECTIVE: Vasoactive agents and inotropes influence conduit-coronary blood flow following coronary artery bypass grafting (CABG). It was hypothesized that dopexamine hydrochloride, a dopamine A-1 (DA-1) and beta(2) agonist would increase conduit-coronary blood flow. A prospective randomized double blind clinical trial was carried out to test this hypothesis. DA-1 receptors have previously been localized to human left ventricle. METHODS: Twenty-six American Society of Anaesthesiology class 2-3 elective coronary artery bypass graft patients who did not require inotropic support on separation from cardiopulmonary bypass (CPB) were studied. According to a randomized allocation patients received either dopexamine (1 microg\\/kg per min) or placebo (saline) by intravenous infusion for 15 min. Immediately prior to and at 5,10 and 15 min of infusion, blood flow through the internal mammary and vein grafts (Transit time flow probes, Transonic Ltd.), heart rate, cardiac index, mean arterial pressure and pulmonary haemodynamics were noted. The data were analysed using multivariate analysis of variance. RESULTS: Low-dose dopexamine (1 microg\\/kg per min) caused a significant increase in mammary graft blood flow compared to placebo at 15 min of infusion (P=0.028, dopexamine group left internal mammary artery (LIMA) flow of 43.3+\\/-14.2 ml\\/min, placebo group LIMA flow at 26.1+\\/-16.3 ml\\/min). Dopexamine recipients demonstrated a non-significant trend to increased saphenous vein graft flow (P=0.059). Increased heart rate was the only haemodynamic change induced by dopexamine (P=0.004, dopexamine group at 85.2+\\/-9.6 beats\\/min and placebo group at 71.1+\\/-7.6 beats\\/min after 15 min of infusion). CONCLUSION: This study demonstrates that administration of dopexamine (1 microg\\/kg per min) was associated with a significant increase in internal mammary artery graft blood flow with mild increase in heart rate being the only haemodynamic change. Low-dose dopexamine may

  2. Hepatic artery stent-grafts for the emergency treatment of acute bleeding

    Energy Technology Data Exchange (ETDEWEB)

    Bellemann, Nadine, E-mail: nadine.bellemann@med.uni-heidelberg.de [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Sommer, Christof-Matthias; Mokry, Theresa; Kortes, Nikolas; Gnutzmann, Daniel; Gockner, Theresa; Schmitz, Anne [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Weitz, Jürgen [Department of Surgery, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany); Department for Visceral, Thoracic and Vascular Surgery at the University Hospital, Technical University Dresden (Germany); Kauczor, Hans-Ulrich; Radeleff, Boris; Stampfl, Ulrike [Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, INF 110, 69120 Heidelberg (Germany)

    2014-10-15

    Highlights: • We report our experiences with stent-grafts for the treatment of acute hemorrhage from the hepatic artery or the stump of the gastroduodenal artery. • The technical success of stent-graft implantation was 88%. • The bleeding ceased immediately after stent-graft implantation in 88%. • The complication rate was 21%. - Abstract: Purpose: We evaluated the technical success and clinical efficacy of stent-graft implantation for the emergency management of acute hepatic artery bleeding. Methods: Between January 2010 and July 2013, 24 patients with hemorrhage from the hepatic artery were scheduled for emergency implantation of balloon expandable stent-grafts. The primary study endpoints were technical and clinical success, which were defined as successful stent-graft implantation with sealing of the bleeding site at the end of the procedure, and cessation of clinical signs of hemorrhage. The secondary study endpoints were complications during the procedure or at follow-up and 30-day mortality rate. Results: In 23 patients, hemorrhage occurred after surgery, and in one patient hemorrhage occurred after trauma. Eight patients had sentinel bleeding. In most patients (n = 16), one stent-graft was implanted. In six patients, two overlapping stent-grafts were implanted. The stent-grafts had a target diameter between 4 mm and 7 mm. Overall technical success was 88%. The bleeding ceased after stent-graft implantation in 21 patients (88%). The mean follow-up was 137 ± 383 days. In two patients, re-bleeding from the hepatic artery occurred during follow-up after 4 and 29 days, respectively, which could be successfully treated by endovascular therapy. The complication rate was 21% (minor complication rate 4%, major complication rate 17%). The 30-day mortality rate was 21%. Conclusions: Implantation of stent-grafts in the hepatic artery is an effective emergency therapy and has a good technical success rate for patients with acute arterial hemorrhage.

  3. Endoscopic Radial Artery Harvest for Coronary Artery Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Kuan-Ming Chiu

    2006-01-01

    Conclusion: Endoscopic harvest of the radial artery is technically demanding, but excellent results can be achieved. The endoscopic approach can provide suitable conduits in a less invasive way than the open harvest technique.

  4. Rare high origin of the radial artery: a bilateral, symmetrical case ...

    African Journals Online (AJOL)

    Arterial variations in the upper limb can occur at the level of the axillary, brachial, radial and ulnar arteries as well as the palmar arches. This is a report of bilateral, symmetrical high origin of the radial artery from the axillary artery. Knowledge of such variations is important in vascular and reconstructive surgery. (Nig J Surg ...

  5. Radial bone graft usage for nasal septal reconstruction

    Directory of Open Access Journals (Sweden)

    Yakup Cil

    2011-01-01

    Full Text Available Background: Although various techniques have been described for correction of crooked and saddle nose deformities, these problems are challenging with high recurrence and revision rates. Conventional septal surgery may not be adequate for nose reconstruction in crooked and saddle nose deformities. Materials and Methods: Between December 2005 and October 2009, six patients with crooked nose and five patients with saddle nose deformities underwent corrective surgery in our clinic. All patients were male, and the mean age was 21 years (range, 19-23 years. We used rigid radial bone graft to prevent redeviation and recurrence following corrective nasal septal surgery. Results: The mean follow-up period was 28 months, ranging from 18 to 46 months. Mean operation time was 4 hours (3-4.5. All patients healed uneventfully. None of the patients required secondary surgery. Conclusions: We believe that radial bone grafts offer a long lasting support in treatment of challenging cases with crooked and saddle nose deformities.

  6. Stent grafting of acute hepatic artery bleeding following pancreatic head resection

    International Nuclear Information System (INIS)

    Stoupis, Christoforos; Ludwig, Karin; Triller, Juergen; Inderbitzin, Daniel; Do, Dai-Do

    2007-01-01

    The purpose of this study was to report the potential of hepatic artery stent grafting in cases of acute hemorrhage of the gastroduodenal artery stump following pancreatic head resection. Five consecutive male patients were treated because of acute, life-threatening massive bleeding. Instead of re-operation, emergency angiography, with the potential of endovascular treatment, was performed. Because of bleeding from the hepatic artery, a stent graft (with the over-the-wire or monorail technique) was implanted to control the hemmorhage by preserving patency of the artery. The outcome was evaluated. In all cases, the hepatic artery stent grafting was successfully performed, and the bleeding was immediately stopped. Clinically, immediately after the procedure, there was an obvious improvement in the general patient condition. There were no immediate procedure-related complications. Completion angiography (n=5) demonstrated control of the hemorrhage and patency of the hepatic artery and the stent graft. Although all patients recovered hemodynamically, three individuals died 2 to 10 days after the procedure. The remaining two patients survived, without the need for re-operation. Transluminal stent graft placement in the hepatic artery is a safe and technically feasible solution to control life-threatening bleeding of the gastroduodenal artery stump. (orig.)

  7. Posttraumatic growth in post-surgical coronary artery bypass graft patients

    Directory of Open Access Journals (Sweden)

    Catherine A Waight

    2015-02-01

    Full Text Available Recent research in posttraumatic growth has been applied to people with life-threatening illnesses to optimise recovery. There is a lack of research exploring posttraumatic growth in coronary artery bypass graft patients. This article describes the recovery experience of 14 coronary artery bypass graft patients (13 males and 1 female at their first outpatient review post-surgery. Grounded theory analysis was used to develop a model of distinct and shared pathways to growth depending on whether patients were symptomatic or asymptomatic pre-coronary artery bypass graft. Outcomes of posttraumatic growth in this sample included action-based healthy lifestyle growth and two forms of cognitive growth: appreciation of life and new possibilities. The model of posttraumatic growth developed in this study may be helpful in guiding future research into promoting posttraumatic growth and behaviour change in coronary artery bypass graft patients.

  8. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  9. Utility of the puncture of the radial artery in interventionist radiology

    International Nuclear Information System (INIS)

    Triana Rodriguez, Carlos Eduardo; Montes S, Mauricio; Barragan F, Jaime; Ucros Diaz Pablo; Ucros Diaz, Ignacio; Castillo, Luis Fernando

    1998-01-01

    We present the radial artery access, previous evaluation of collateral circulation with Allen's Test, as an alternative vascular access in patients with contraindications for femoral or axillary approaches. The radial artery puncture offers advantages, such as diminished bleeding and hematoma formation

  10. Radial artery spasm occurred in transradial coronary intervention for coronary heart disease: its occurrence and predictors

    International Nuclear Information System (INIS)

    Zhong Jiming; Li Lang; Lu Yongguang; Zeng Shuyi

    2011-01-01

    Objective: To discuss the incidence and clinical predictors of radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease. Methods: A total of 1020 patients, who underwent transradial coronary procedures for coronary heart disease during the period of May 2007 Jan 2010 in authors' hospital, were enrolled in this study. All clinical information and medication were recorded in detail. Arteriography via radial artery was performed in all patients. The diameter of the radial artery as well as the arterial anatomy, including arterial variations, were determined and observed, which was follow by coronary angiography or percutaneous coronary intervention. Multivariate Logistic regression analysis was adopted to evaluate the variables, such as clinical parameters, angiographic characteristics of the radial artery and procedure-related factors, in predicting the occurrence of radial artery spasm. Results: Radial artery spasm occurred in 209 (20.5%) patients. Multivariate Logistic regression analysis showed that the following eight factors were independently associated with the occurrence of radial artery spasm. These factors were as follows: female gender (OR=2.8, 95% CI 2.5-5.8; P=0.001), age (OR=0.68, 95% CI 0.60-0.92; P=0.003), smoking (OR=2.3, 95% CI 1.8-4.1; P=0.026), moderate-to-severe pain of forearm during radial artery cannulation (OR=3.0, 95% CI 2.3-4.8; P=0.006), radial artery anatomical abnormalities (OR=4.7, 95% CI 3.6-7.2; P=0.002), the ratio of radial artery diameter to patient's height (RAH) (OR=5.2, 95% CI 3.7-8.1; P=0.012), the ratio of radial artery diameter to outer diameter of the sheath (RAOD) (OR=5.8, 95% CI 4.2-6.9; P=0.006) and the number of catheter exchange (OR=2.3, 95% CI 1.4-4.3; P=0.038). Conclusion: Radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease is frequently seen in clinical practice. Female gender, younger age, smoking, forearm pain during

  11. Infrascrotal, perineal, femorofemoral bypass for arterial graft infection at the groin.

    Science.gov (United States)

    Illuminati, Giulo; Caliò, Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2004-12-01

    Infrascrotal, perineal, femorofemoral bypass is an acceptable procedure for treating infection of a prosthetic arterial graft limited to a unilateral groin. A consecutive sample clinical study with a mean follow-up of 29 months. The surgical department of an academic tertiary care center and an affiliated secondary care center. Nineteen patients with a mean age of 68 years with prosthetic graft infection at the outflow anastomosis on a femoral artery at the Scarpa triangle underwent an infrascrotal, perineal, femorofemoral bypass, with excision of the graft material limited at the groin. The recipient artery was the profunda femoris artery in 12 cases, the superficial femoral in 5, and the distal common femoral artery in 2. Cumulative survival, recurrence of sepsis, primary graft patency, and limb salvage rates expressed by standard life-table analysis. Postoperative mortality rate was 5%. Cumulative (SE) survival rate was 65% (11.6%) at 3 years. Cumulative (SE) rate of freedom from recurrent sepsis was 88% (8.6%) at 3 years. Cumulative (SE) primary patency and limb salvage rates were 86% (9.4%) and 91% (7.9%), respectively, at 3 years. Femorofemoral bypass with an infrascrotal perineal approach is a valuable procedure for the treatment of femoral arterial graft infection limited at a unilateral groin.

  12. Aneurisma idiopático de artéria radial: relato de caso Idiopathic radial artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    Luiz Ernani Meira Jr.

    2011-12-01

    Full Text Available Os aneurismas da artéria radial são extremamente raros. Em sua maioria, consistem de pseudoaneurismas pós-traumáticos. Os aneurismas da artéria radial verdadeiros podem ser idiopáticos, congênitos, pós-estenóticos ou associados a patologias, tais como vasculites e doenças do tecido conjuntivo. Foi relatado um caso de aneurisma idiopático de artéria radial em uma criança de três anos, que, após completa investigação diagnóstica complementar, foi submetida à ressecção cirúrgica.Radial artery aneurysms are extremely rare. Post-traumatic pseudoaneurysms are the vast majority. True radial artery aneurysms can be idiopathic, congenital, poststenotic, or associated with some pathologies, such as vasculitis and conjunctive tissue diseases. We report a case of an idiopathic aneurysm of the radial artery in a three-year-old child who was submitted to surgical resection after a complete diagnostic approach.

  13. Influence of Diabetes on Long-Term Coronary Artery Bypass Graft Patency.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Rajeswaran, Jeevanantham; Riaz, Haris; Bakaeen, Faisal G; Lincoff, A Michael; Sabik, Joseph F

    2017-08-01

    Nearly 50% of patients undergoing coronary artery bypass grafting have diabetes. However, little is known about the influence of diabetes on long-term patency of bypass grafts. Because patients with diabetes have more severe coronary artery stenosis, we hypothesized that graft patency is worse in patients with than without diabetes. This study sought to examine the influence of diabetes on long-term patency of bypass grafts. From 1972 to 2011, 57,961 patients underwent primary isolated coronary artery bypass grafting. Of these, 1,372 pharmacologically treated patients with diabetes and 10,147 patients without diabetes had 15,887 postoperative angiograms; stenosis was quantified for 7,903 internal thoracic artery (ITA) grafts and 20,066 saphenous vein grafts. Status of graft patency across time was analyzed by longitudinal nonlinear mixed-effects modeling. ITA graft patency was stable over time and similar in patients with and without diabetes: at 1, 5, 10, and 20 years, 97%, 97%, 96%, and 96% in patients with diabetes, and 96%, 96%, 95%, and 93% in patients without diabetes, respectively (early p = 0.20; late p = 0.30). In contrast, saphenous vein graft patency declined over time and similarly in patients with and without diabetes: at 1, 5, 10, and 20 years, 78%, 70%, 57%, and 42% in patients with diabetes, and 82%, 72%, 58%, and 41% in patients without diabetes, respectively (early p < 0.002; late p = 0.60). After adjusting for patient characteristics, diabetes was associated with higher early patency of ITA grafts (odds ratio: 0.63; 95% confidence limits: 0.43 to 0.91; p = 0.013), but late patency of ITA grafts was similar in patients with and without diabetes (p = 0.80). Early and late patency of saphenous vein grafts were similar in patients with and without diabetes (early p = 0.90; late p = 0.80). Contrary to our hypothesis, diabetes did not influence long-term patency of bypass grafts. Use of ITA grafts should be maximized in patients

  14. Evaluation of Blood Hemodynamics in Vascular Grafts after Total Arterial Coronary Revascularization

    Directory of Open Access Journals (Sweden)

    Ahmad Ali Amirghofran

    2016-07-01

    Full Text Available Arterial grafting has increasingly been advocated for the treatment of coronary artery disease in an attempt to improve the long-term results. In the quest to perform routine total arterial revascularization, composite Y graft methods are gaining popularity. The aim of our study was to evaluate whether blood flow in the left internal thoracic artery can provide sufficient perfusion to the entire cardiac muscle per se. Twenty patients with severe coronary artery stenosis who underwent complete arterial coronary revascularization using a composite graft entered our study. Blood flow in thoracic trunk was evaluated in three phases: cross-clamp on, cross-clamp off, and after weaning the patient from cardiopulmonary bypass. Mean arterial blood pressure in the thoracic trunk in these various positions was 62.7±3.7. left internal thora cic artery can provide sufficient blood flow to the cardiac muscles for both rest and exercise conditions.

  15. Intimal hyperplasia and wall shear in arterial bypass graft distal anastomoses: an in vivo model study.

    Science.gov (United States)

    Keynton, R S; Evancho, M M; Sims, R L; Rodway, N V; Gobin, A; Rittgers, S E

    2001-10-01

    The observation of intimal hyperplasia at bypass graft anastomoses has suggested a potential interaction between local hemodynamics and vascular wall response. Wall shear has been particularly implicated because of its known effects upon the endothelium of normal vessels and, thus, was examined as to its possible role in the development of intimal hyperplasia in arterial bypass graft distal anastomoses. Tapered (4-7 mm I.D.) e-PTFE synthetic grafts 6 cm long were placed as bilateral carotid artery bypasses in six adult, mongrel dogs weighing between 25 and 30 kg with distal anastomotic graft-to-artery diameter ratios (DR) of either 1.0 or 1.5. Immediately following implantation, simultaneous axial velocity measurements were made in the toe and artery floor regions in the plane of the anastomosis at radial increments of 0.35 mm, 0.70 mm, and 1.05 mm using a specially designed 20 MHz triple crystal ultrasonic wall shear rate transducer Mean, peak, and pulse amplitude wall shear rates (WSRs), their absolute values, the spatial and temporal wall shear stress gradients (WSSG), and the oscillatory shear index (OSI) were computed from these velocity measurements. All grafts were harvested after 12 weeks implantation and measurements of the degree of intimal hyperplasia (IH) were made along the toe region and the artery floor of the host artery in 1 mm increments. While some IH occurred along the toe region (8.35+/-23.1 microm) and was significantly different between DR groups (p<0.003), the greatest amount occurred along the artery floor (81.6+/-106.5 microm, mean +/- S.D.) (p < 0.001) although no significant differences were found between DR groups. Linear regressions were performed on the paired IH and mean, peak, and pulse amplitude WSR data as well as the absolute mean, peak, and pulse amplitude WSR data from all grafts. The mean and absolute mean WSRs showed a modest correlation with IH (r = -0.406 and -0.370, respectively) with further improvements seen (r = -0

  16. Axillary artery to left anterior descending coronary artery bypass with an externally stented graft: a technical report

    Directory of Open Access Journals (Sweden)

    Salvador Loris

    2008-02-01

    Full Text Available Abstract With the proliferation of minimally invasive cardiac surgery a number of alternative inflow sites for coronary artery bypass grafting have been utilized, especially in higher risk patients. The use of axillary-coronary artery bypass is a safe and effective alternative especially in the case of patients requiring redo coronary revascularization. However, the length and convoluted course of the axillary-coronary vein graft makes is susceptible to twisting, trauma and neointimal hyperplasia. We therefore report a case of an axillary-coronary artery bypass in a high risk patient in which a Dacron conduit was used to externally support and protect the vein graft to the left anterior descending artery. Surgical technique and considerations are presented and discussed.

  17. Improving the Outcome of Vein Grafts: Should Vascular Surgeons Turn Veins into Arteries?

    OpenAIRE

    Isaji, Toshihiko; Hashimoto, Takuya; Yamamoto, Kota; Santana, Jeans M.; Yatsula, Bogdan; Hu, Haidi; Bai, Hualong; Jianming, Guo; Kudze, Tambudzai; Nishibe, Toshiya; Dardik, Alan

    2017-01-01

    Autogenous vein grafts remain the gold standard conduit for arterial bypass, particularly for the treatment of critical limb ischemia. Vein graft adaptation to the arterial environment, i.e., adequate dilation and wall thickening, contributes to the superior performance of vein grafts. However, abnormal venous wall remodeling with excessive neointimal hyperplasia commonly causes vein graft failure. Since the PREVENT trials failed to improve vein graft outcomes, new strategies focus on the ada...

  18. Percutaneous coronary intervention versus coronary-artery bypass grafting for severe coronary artery disease

    NARCIS (Netherlands)

    P.W.J.C. Serruys (Patrick); M-C. Morice (Marie-Claude); A.P. Kappetein (Arie Pieter); A. Colombo (Antonio); D.R. Holmes Jr (David); M.J. Mack (Michael); E. Stahle (Elisabeth); T.E. Feldman (Ted); M.J.B.M. van den Brand (Marcel); E.J. Bass (Eric); N. van Dyck (Nic); K. Leadly (Katrin); K.D. Dawkins (Keith); F.W. Mohr (Friedrich)

    2009-01-01

    textabstractBACKGROUND Percutaneous coronary intervention (PCI) involving drug-eluting stents is increasingly used to treat complex coronary artery disease, although coronary-artery bypass grafting (CABG) has been the treatment of choice historically. Our trial compared PCI and CABG for treating

  19. Barriers to the universal adoption of bilateral internal mammary artery grafting.

    Science.gov (United States)

    Umakanthan, Jeremiah; Jeyakumar, Panch; Umakanthan, Branavan; Jeyakumar, Nikeshan; Senthilkumar, Nadarajah; Saraswathy, Mathioli R; Umakanthan, Padminidevi; Umakanthan, Janani; Sial, Tamoor; Abrina, Sofia; Buendia, Frances M; Pan, Irene; Kamath, Ramadas K; Pathmarajah, Canagaratnam; Sivalingam, Kanagaratnam; Nathan, Shan A; Sunder, Shun K; Mahendra, Tom; Umakanthan, Ramanan

    2015-04-01

    The left internal mammary artery (LIMA) graft is considered the "gold standard" of coronary artery bypass grafting (CABG). This conduit provides increased survival, symptomatic relief, increased freedom from myocardial infarction, and increased freedom from re-intervention when compared to saphenous venous grafting. It has a remarkable long term patency rate with clinical and angiographic outcomes that are unmatched by other conduits. Given the fact that patients often require more than one graft during a coronary revascularization procedure, the prospect of bilateral internal mammary artery (BIMA) grafting has been very appealing to some surgeons. BIMA grafting has been extensively studied via multiple retrospective and prospective cohort studies and findings have indicated that BIMA grafting can have an increased survival benefit when compared to LIMA grafting alone. As a result, this technique has accrued increasing popularity over the course of the last decade. Yet, questions still remain on whether BIMA grafting is the optimal treatment modality for patients in terms of long-term prognosis. There is limited data at the present time from randomized controlled trials and only 4-12% of CABGs performed today utilize BIMA grafting. Concerns regarding perioperative complications, which patient subsets are at higher risks for complications from the technique, and the technical challenges involved in utilizing and teaching the technique have limited its widespread use. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  20. High Origin of Radial Arteries: A Report of Two Rare Cases

    Directory of Open Access Journals (Sweden)

    Dong Zhan

    2010-01-01

    Full Text Available Variations in the arterial supply of the upper limb are relatively common, with reported prevalence rates ranging from 11 to 24.4%. Of these, the most commonly encountered variation in the arm is a high origin of the radial artery. However, after consecutively dissecting and examining 600 Singaporean Chinese cadavers (1,200 upper limbs, we found only two cases of this. In both cases, the brachioradial artery originated from the upper one-third of the brachial artery and continued distally as the radial artery in the forearm. The local prevalence of 0.33% of this variation is significantly lower compared against populations from other geographical regions. Although rare, recognition of the variation is of fundamental importance to clinical practice.

  1. Pattern and predictors of dual antiplatelet use after coronary artery bypass graft surgery.

    Science.gov (United States)

    Mori, Makoto; Shioda, Kayoko; Yun, James J; Mangi, Abeel A; Darr, Umer; Geirsson, Arnar

    2018-02-01

    Resumption of dual antiplatelet therapy after coronary artery bypass grafting in patients presenting with acute coronary syndrome is recommended, but the current practice pattern in the United States remains unknown. We aimed to investigate the current pattern of dual antiplatelet therapy use after coronary artery bypass grafting at the Yale-New Haven Hospital. We conducted a single-center retrospective review of patients who presented with acute coronary syndrome and underwent coronary artery bypass grafting between 2014 and 2016. The primary outcome was hospital discharge with dual antiplatelet therapy. Mixed-effect multivariate logistic regression was used to evaluate predictors of dual antiplatelet therapy use or nonuse, accounting for surgeon-specific preference. The discriminatory ability of the model was evaluated with receiver operating characteristics analysis. Of 572 patients included, only 29% were discharged with dual antiplatelet therapy. In the mixed-effect multivariate model isolating surgeon preferences, increase in age (odds ratio, 0.95; 95% confidence interval, 0.92-0.98; P dual antiplatelet therapy use. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting was associated with increased odds of dual antiplatelet therapy use (odds ratio, 31.5; 95% confidence interval, 12.8-77.2; P dual antiplatelet therapy use in patients with acute coronary syndrome who underwent coronary artery bypass grafting was low and variable among surgeons. The use or nonuse was guided by previously established risk factors of recurrent ischemia and bleeding, along with surgeon preference. Published by Elsevier Inc.

  2. Cognitive outcomes in elderly high-risk patients after off-pump versus conventional coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Jensen, Birte Ostergaard; Hughes, Pia; Rasmussen, Lars S

    2006-01-01

    It has been suggested that the risk of cerebral dysfunction is less with off-pump coronary artery bypass grafting (OPCAB) than with conventional coronary artery bypass grafting (CCAB). However, evidence for this statement is preliminary, and additional insight is needed.......It has been suggested that the risk of cerebral dysfunction is less with off-pump coronary artery bypass grafting (OPCAB) than with conventional coronary artery bypass grafting (CCAB). However, evidence for this statement is preliminary, and additional insight is needed....

  3. Coronary artery bypass grafting and concomitant excision of chest wall chondrosarcoma

    Directory of Open Access Journals (Sweden)

    Ganti Somsekhar

    2009-02-01

    Full Text Available Abstract Coexistence of coronary artery disease and cancer with both requiring surgical treatment at the same time is rare. A 52 year male undergoing elective coronary artery bypass grafting was incidentally discovered to have a large soft tissue mass of variable consistency with cartilaginous elements arising from the right costal margin and adjoining ribs by a broad attachment and protruding into right pleural cavity. Frozen section suggested it to be either a chondrosarcoma or a teratoma. A wide excision of the mass with the adjoining muscle and periosteum along with quadruple coronary artery bypass grafting was done. This report is unusual on account of a being the first reported case in world literature of concomitant excision of chondrosarcoma and coronary artery bypass grafting and b the conservative management of the incidentally discovered chondrosarcoma by wide excision rather than chest wall resection with no local recurrence to date. Pathology of chondrosarcoma, in particular, and various management strategies when coronary artery disease and cancer coexist, in general, is discussed.

  4. Platelet hyperreactivity in response to on- and off-pump coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Bochsen, Louise; Rosengaard, Lisbeth Bredahl; Nielsen, Allan Bybeck

    2009-01-01

    Hypercoagulability has been reported after off-pump coronary artery bypass grafting (OPCAB) compared with patients undergoing standard coronary artery bypass grafting (CABG) with cardiopulmonary bypass. The aim of this study was to evaluate the changes in platelet reactivity in response to cardiac...... and this study identified 23% of patients needing coronary bypass surgery to be at high risk for recurrent ischemic events at 1 month after surgery, based on the MA. These results suggest that a more aggressive antithrombotic treatment might be warranted for patients undergoing coronary artery bypass grafting...

  5. Analysis of linguistic terms of variables representing the wave of arterial diameter variation in radial arteries using fuzzy entropies

    International Nuclear Information System (INIS)

    Nuno Almirantearena, F; Introzzi, A; Clara, F; Burillo Lopez, P

    2007-01-01

    In this work we use 53 Arterial Diameter Variation (ADV) waves extracted from radial artery of normotense males, along with the values of variables that represent the ADV wave, obtained by means of multivariate analysis. Then, we specify the linguistic variables and the linguistic terms. The variables are fuzzified using triangular and trapezoidal fuzzy numbers. We analyze the fuzziness of the linguistic terms by applying discrete and continuous fuzzy entropies. Finally, we infer which variable presents the greatest disorder associated to the loss of arterial elasticity in radial artery

  6. Use of multidetector computed tomography angiography of upper limb circulation in patients undergoing coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Hasan B Altinsoy

    2017-01-01

    Full Text Available Objective: This study aimed to evaluate the bilateral forehand circulation using a 64-channel multidetector computed tomography (MDCT as a noninvasive method to define criteria for an upper extremity arterial anatomy and pathology prior to the use of arterial conduits. Materials and Methods: Fifty-five patients with coronary artery disease who underwent total arterial coronary artery bypass grafting (CABG were randomly selected for this prospective study. MDCT angiography was performed for 110 examinations of forearm and hand arterial anatomy. Prior to MDCT, Allen tests were performed in all patients with a normal result, except four. Thirteen patients had diabetes mellitus (DM, 8 had peripheral artery occlusive disease, and 19 had a history of smoking. Results: All arteries, including axillary, ulnar artery (UA and radial artery (RA, were clearly visualized in all patients. Upper extremity anatomical and pathological results were examined in 16 patients (29.1%. Severely calcified RA and/or UA were found in 6 patients who had a moderate renal failure. Nearly total occlusion of the RA was detected in another two patients. Focal intimal RA calcification was recorded in 1 female and 3 male patients. Ten patients who had severe calcification or intimal sclerosis of the upper extremity arteries had DM. The remaining patients had normal forehand arterial circulation. A persistent median artery with the absence of radial and ulnar arteries and a high bifurcation of RA from the brachial artery was detected as an anatomic variation in seven patients (12.7%. Conclusions: The major advantages of MDCT angiography are its non-invasiveness and the ability to detect calcific subadventitial plaques, which are difficult to diagnose using conventional angiography. MDCT may be used as a safe and non-invasive method to assess RA and UA prior to harvesting the upper limb artery. Preoperative imaging of forehand arteries is a means to avoid unnecessary forearm

  7. Plasma magnesium concentration in patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Kotlinska-Hasiec, Edyta; Makara-Studzinska, Marta; Czajkowski, Marek; Rzecki, Ziemowit; Olszewski, Krzysztof; Stadnik, Adam; Pilat, Jacek; Rybojad, Beata; Dabrowski, Wojciech

    2017-05-11

    [b]Introduction[/b]. Magnesium (Mg) plays a crucial role in cell physiology and its deficiency may cause many disorders which often require intensive treatment. The aim of this study was to analyse some factors affecting preoperative plasma Mg concentration in patients undergoing coronary artery bypass grafting (CABG). [b]Materials and method[/b]. Adult patients scheduled for elective CABG with cardio-pulmonary bypass (CPB) under general anaesthesia were studied. Plasma Mg concentration was analysed before surgery in accordance with age, domicile, profession, tobacco smoking and preoperative Mg supplementation. Blood samples were obtained from the radial artery just before the administration of anaesthesia. [b]Results. [/b]150 patients were studied. Mean preoperative plasma Mg concentration was 0.93 ± 0.17 mmol/L; mean concentration in patients - 1.02 ± 0.16; preoperative Mg supplementation was significantly higher than in patients without such supplementation. Moreover, intellectual workers supplemented Mg more frequently and had higher plasma Mg concentration than physical workers. Plasma Mg concentration decreases in elderly patients. Patients living in cities, on average, had the highest plasma Mg concentration. Smokers had significantly lower plasma Mg concentration than non-smokers. [b]Conclusions. [/b]1. Preoperative magnesium supplementation increases its plasma concentration. 2. Intellectual workers frequently supplement magnesium. 3. Smoking cigarettes decreases plasma magnesium concentration.

  8. Long-term internal thoracic artery bypass graft patency and geometry assessed by multidetector computed tomography

    DEFF Research Database (Denmark)

    Zacho, Mette; Damgaard, Sune; Lilleoer, Nikolaj Thomas

    2012-01-01

    The left internal thoracic artery (LITA) undergoes vascular remodelling when used for coronary artery bypass grafting. In this study we tested the hypothesis that the extent of the LITA remodelling late after coronary artery bypass grafting assessed by multidetector computed tomography is related...

  9. [Successful correction with stent-graft of coronary artery rupture after angioplasty].

    Science.gov (United States)

    Demin, V V

    2003-01-01

    Rupture and perforation of coronary arteries complicate in average 0.5% of radiosurgical coronary interventions and often are accompanied by serious consequences and high mortality. According to-type of coronary perforation different methods of correction are used, ranging from conservative measures to urgent cardiosurgical interventions. Coronary stent-grafts with 'sandwich' type of construction ore composed from two metal stents and PTFE layer between them. Development of such stents enabled effective radioguided endovascular repair of coronary ruptures. The paper presents the first Russian experience of stout-graft implantation for coronary artery rupture occurred during direct stenting of proximal anterior descending artery and balloon angioplasty in distal segment. The rupture occurred probably because of wall fragility between affected segment and muscular bridge. Stent-graft JoStent 16 mm in length connected with 3-mm balloon was implanted with subsequent complete restitution of blood flow, resolution of pain syndrome and ECG normalization. Echocardiography in operative theatre and one day after surgery showed no intrapericardial fluid. Stent-graft devices for urgent implantation in cases of coronary rupture must be included into obligatory equipment of radiosurgical facilities.

  10. Intra-arterial vasodilators to prevent radial artery spasm: a systematic review and pooled analysis of clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, Chun Shing, E-mail: shingkwok@doctors.org.uk [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Rashid, Muhammad [St. Helens & Knowsley Teaching Hospital (NHS) Trust, Whiston Hospital, Prescot (United Kingdom); Fraser, Doug [Manchester Heart Centre, Manchester Royal Infirmary (United Kingdom); Nolan, James [University Hospital of North Midlands, Stoke-on-Trent (United Kingdom); Mamas, Mamas [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Farr Institute, Institute of Population Health, University of Manchester, Manchester (United Kingdom)

    2015-12-15

    Objectives: The aim of this study is to review the available literature on the efficacy and safety of agents used for prevention of RAS. Background: Different vasodilator agents have been used to prevent radial artery spasm (RAS) in patients undergoing transradial cardiac catheterization. Methods: We included studies that evaluated any intra-arterial drug administered in the setting cardiac catheterization that was undertaken through the transradial access site (TRA). We also compared studies for secondary outcomes of major bleeding, procedure time, and procedure failure rate in setting of RAS prevention, patent hemostasis and radial artery occlusion. Results: 22 clinical studies met the inclusion criteria. For placebo, RAS rate was 12% (4 studies, 638 participants), which was similar to 2.5 mg of verapamil 12% (3 studies, 768 participants) but greater than 5 mg of verapamil (4%, 2 studies, 497 participants). For nicorandil, there was a much higher RAS rate compared to placebo (16%, 3 studies, 447 participants). The lowest rates of RAS was found for nitroglycerin at both 100 μg (4%) and 200 μg (2%) doses, isosorbide mononitrate (4%) and nicardipine (3%). We found no information regarding the procedure failure rates, patent hemostasis, and radial artery occlusion in these studies. Conclusions: In this largest and up-to-date review on intra-arterial vasodilators use to reduce RAS, we have found that the verapamil at a dose of 5 mg or verapamil in combination with nitroglycerine are the best combinations to reduce RAS. - Highlights: • Radial artery spasm (RAS) causes procedural failure in transradial catheterization. • RAS may complicate 10–15% procedures undertaken through the radial approach. • We reviewed the efficacy of vasodilators that have been used to minimize RAS. • The pooled RAS rate was lowest with 5 mg of verapamil (4%) compared to placebo (12%). • The best combination of drugs to minimize RAS is nitroglycerine and verapamil.

  11. Simultaneous nephrectomy and coronary artery bypass grafting through extended sternotomy

    Directory of Open Access Journals (Sweden)

    Budrikis Algimantas

    2012-08-01

    Full Text Available Abstract Background The advances in surgical techniques, resuscitation and anesthesiology support over the last years have allowed simultaneous thoracic and abdominal operations to be made for cancer and concomitant severe heart vessel disease relieving the patient from several diseases simultaneously and achieving long lasting remission or cure. Clinical case A simultaneous nephrectomy and coronary artery bypass grafting procedure through extended sternotomy is reported. A 63-year-old man with severe coronary artery disease was found to have renal carcinoma. Diagnosis Postoperative pathological investigation of the tumor revealed the presence of renal cell carcinoma pT3a N0 M0, G2. Coronarography revealed advanced three-vessel coronary artery disease. Treatment We successfully performed a simultaneous curative surgery for renal carcinoma and coronary artery bypass graft surgery under cardiopulmonary bypass using a novel technique of extended sternotomy. Simultaneous surgery thus appears to be a beneficial and safe approach for the treatment of coronary artery disease and resectable renal cancer in carefully selected patients.

  12. Pseudoaneurysm of the Radial Artery After a Bicycle Fall.

    Science.gov (United States)

    Ratschiller, Thomas; Müller, Hannes; Schachner, Thomas; Zierer, Andreas

    2018-07-01

    We report a case of a 64-year-old man who developed a painful pulsatile mass in the distal forearm after a bicycle fall with fracture of the wrist. Ultrasonography confirmed a 2.5-cm large pseudoaneurysm of the radial artery. The patient underwent surgical exploration. The pseudoaneurysm was resected and the defect in the arterial wall was reconstructed with an autologous saphenous vein patch. We suggest that the double arterial supply of the hand should be preserved whenever possible.

  13. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  14. 2-Octyl Cyanoacrylate (Dermabond® skin adhesive versus polyglactin for skin closure in endoscopic radial artery harvesting

    Directory of Open Access Journals (Sweden)

    Ahmed Mostafa Omran

    2018-03-01

    Full Text Available Background: As the goal of endoscopic conduit harvesting is to decrease pain and better cosmetic appearance, and as the optimal choice of skin closure after endoscopic radial artery harvesting (ERAH has not yet been determined, we started this study with an aim to compare wound complications, patient satisfaction and scar healing between glue (Dermabond versus polyglactin intra-cuticular suture for skin closure after ERAH. Methods: This observational study was done at Al Dabbous Cardiac Center, Kuwait, from January 2017 till October 2017 enrolling 40 patients divided into two equal groups (Dermabond group and sutures group. Inclusion criterion was patients underwent coronary artery bypass grafting (CABG using ERAH, while open technique for radial artery harvesting and Negro race are considered as exclusion criteria. Demographic data were collected, (gender, age, race, body mass index (BMI, preoperative medication and albumin level, as well as diabetes or peripheral vascular disease. Operatively, wound closure time was calculated for all patients. Postoperatively: Cosmetic appearance was assessed using the Hollander scale. Patient satisfaction was recorded at week 6–8 weeks. Results: Demographic and preoperative data were comparable; Dermabond group showed shorter closure time, better scar pigmentation, shape and patient satisfaction. Pain, scar size, infection and hematoma showed no statistical difference. Conclusion: Dermabond can be used safely in closure of skin after ERAH. The excellent results in the small wound of ERAH encouraged us to use it in larger wounds. Keywords: Dermabond, Wound, ERAH, Skin adhesive, OCA

  15. Does Off-Pump Coronary Artery Bypass Grafting Negatively Impact Long-Term Survival and Freedom from Reintervention?

    Directory of Open Access Journals (Sweden)

    Shahzad G. Raja

    2013-01-01

    Full Text Available Recently published evidence has raised concerns about worse late mortality and increasing need for reintervention after off-pump coronary artery bypass grafting. We undertook this study to assess the impact of off-pump coronary artery bypass grafting on survival and freedom from reintervention at 10 years. From January 2002 to December 2002, 307 consecutive patients who had isolated multivessel off-pump coronary artery bypass grafting at our institution were compared to a control group of 397 patients that underwent multivessel on-pump coronary artery bypass grafting during the same period. In addition, univariate and risk-adjusted comparisons between the two groups were performed at 10 years. Kaplan-Meier survival was similar for the two cohorts. After adjusting for clinical covariates, off-pump coronary artery bypass grafting did not emerge as a significant independent predictor of long-term mortality (Hazard Ratio 0.91; 95% Confidence Interval 0.70–1.12, readmission to hospital for cardiac cause (Hazard Ratio 0.96; 95% Confidence Interval 0.78–1.10, or the need for reintervention (Hazard Ratio 0.93; 95% Confidence Interval 0.87–1.05. Off-pump coronary artery bypass grafting compared with on-pump coronary artery bypass grafting does not adversely impact survival or freedom from reintervention at a 10-year follow-up.

  16. Double-layered collagen graft to the radial forearm free flap donor sites without skin graft.

    Science.gov (United States)

    Park, Tae-Jun; Kim, Hong-Joon; Ahn, Kang-Min

    2015-12-01

    Radial forearm free flap is the most reliable flap for intraoral soft tissue reconstruction after cancer ablation surgery. However, unesthetic scar of the donor site and the need for a second donor site for skin graft are major disadvantages of the forearm flap. The purpose of this study was to report the clinical results of double-layered collagen graft to the donor site of the forearm free flap without skin graft. Twenty-two consecutive patients who underwent oral cancer ablation and forearm reconstruction between April 2010 and November 2013 were included in this study. Male to female ratio was 12:10, and average age was 61.0 years old (27-84). Double-layered collagen was grafted to the donor site of the forearm free flap and healed for secondary intention. Upper silicone had been trimmed at the periphery during secondary intention, and dry dressing was used. Postoperative scar healing and esthetic results and function were evaluated. An average follow-up period was 34.9 months. The scar area was decreased to 63.9 % in average. The complete healing was obtained between 1.5 and 3 months according to the defect size. There was no functional defect or impairment 3 months after operation. All patients were satisfied with the esthetic results. Three patients died of recurred cancer. Double-layered collagen graft was successfully performed in this study. Without the thigh skin graft, patients had experienced less painful postoperative healing periods and discomfort.

  17. Radial motion of the carotid artery wall: A block matching algorithm approach

    Directory of Open Access Journals (Sweden)

    Effat Soleimani

    2012-06-01

    Full Text Available Introduction: During recent years, evaluating the relation between mechanical properties of the arterialwall and cardiovascular diseases has been of great importance. On the other hand, motion estimation of thearterial wall using a sequence of noninvasive ultrasonic images and convenient processing methods mightprovide useful information related to biomechanical indexes and elastic properties of the arteries and assistdoctors to discriminate between healthy and diseased arteries. In the present study, a block matching basedalgorithm was introduced to extract radial motion of the carotid artery wall during cardiac cycles.Materials and Methods: The program was implemented to the consecutive ultrasonic images of thecommon carotid artery of 10 healthy men and maximum and mean radial movement of the posterior wall ofthe artery was extracted. Manual measurements were carried out to validate the automatic method andresults of two methods were compared.Results: Paired t-test analysis showed no significant differences between the automatic and manualmethods (P>0.05. There was significant correlation between the changes in the instantaneous radialmovement of the common carotid artery measured with the manual and automatic methods (withcorrelation coefficient 0.935 and P<0.05.Conclusion: Results of the present study showed that by using a semi automated computer analysismethod, with minimizing the user interfere and no attention to the user experience or skill, arterial wallmotion in the radial direction can be extracted from consecutive ultrasonic frames

  18. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  19. Costo-osteochondral graft for post-traumatic osteonecrosis of the radial head in an adolescent boy.

    Science.gov (United States)

    Iwai, S; Sato, K; Nakamura, T; Okazaki, M; Itoh, Y; Toyama, Y; Ikegami, H

    2011-01-01

    We present a case of post-traumatic osteonecrosis of the radial head in a 13-year-old boy which was treated with costo-osteochondral grafts. A satisfactory outcome was seen at a follow-up of two years and ten months. Although costo-osteochondral grafting has been used in the treatment of defects in articular cartilage, especially in the hand and the elbow, the extension of the technique to manage post-traumatic osteonecrosis of the radial head in a child has not previously been reported in the English language literature. Complete relief of pain was obtained and an improvement in the range of movement was observed. The long-term results remain uncertain.

  20. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  1. Off-pump versus on-pump coronary artery bypass grafting for ischaemic heart disease

    DEFF Research Database (Denmark)

    Møller, Christian H; Penninga, Luit; Wetterslev, Jørn

    2012-01-01

    Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear.......Coronary artery bypass grafting (CABG) is performed both without and with cardiopulmonary bypass, referred to as off-pump and on-pump CABG respectively. However, the preferable technique is unclear....

  2. Survival results of postoperative coronary angiogram for treatment of perioperative myocardial ischaemia following coronary artery bypass grafting: a single-centre experience.

    Science.gov (United States)

    Preußer, Maximilian J; Landwehrt, Jan; Mastrobuoni, Stefano; Biancari, Fausto; Dakkak, Abdul R; Alshakaki, Mosab; Martens, Sven; Dell'Aquila, Angelo M

    2018-02-01

    Although perioperative myocardial ischaemia (PMI) is a well-known complication following coronary artery bypass grafting (CABG), standard strategies for its diagnosis and treatment are so far not defined. In this study, we sought to evaluate the impact on survival of postoperative coronary angiogram for management of patients with PMI after CABG. Overall, 4028 patients underwent isolated CABG in a single-centre institution between January 2006 and September 2013. A total of 168 (4.2%) patients received postoperative coronary angiogram because of diagnosis of PMI. These patients were matched on the basis of gender, age at surgery and date of surgery, with 336 (1:2 ratio) CABG patients without PMI to determine the impact of the PMI management. A total of 476 grafts were examined (263 venous grafts, 196 internal mammary artery grafts and 17 radial artery grafts). Almost three-quarters of the 168 PMI (74.4%) patients underwent postoperative coronary angiogram within 24 h of surgery. Normal postoperative coronary angiogram, graft failure and new native vessels occlusion were observed in 23.2%, 52.4% and 24.4% of patients, respectively. A total of 30 (17.9%) patients underwent surgical revision of grafts, whereas 60 (35.7%) patients were treated with percutaneous coronary intervention. Eighteen (10.7%) PMI patients died during the hospital stay compared with 6 (1.8%) patients in the non-PMI group. Survival rates at 7 years were 62.5% in the PMI group and 81.1% in non-PMI group (P PMI (P 24 h after surgery) was an independent predictor of poorer mid-term survival (P = 0.008; hazard ratio 3.62, 95% confidence interval 1.41-9.33). PMI after CABG is associated with a significantly poorer survival. A prompt postoperative management must always be considered. Further prospective studies are required to confirm our results. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights

  3. A novel compliance measurement in radial arteries using strain-gauge plethysmography

    International Nuclear Information System (INIS)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-01-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C strain ) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29–85 were compared with 14 normotensive patients aged 25–62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005)

  4. A novel compliance measurement in radial arteries using strain-gauge plethysmography.

    Science.gov (United States)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-09-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the Z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C(strain)) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29-85 were compared with 14 normotensive patients aged 25-62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005).

  5. Percutaneous subclavian artery stent-graft placement following failed ultrasound guided subclavian venous access

    Directory of Open Access Journals (Sweden)

    Szkup Peter

    2006-05-01

    Full Text Available Abstract Background Ultrasound guidance for central and peripheral venous access has been proven to improve success rates and reduce complications of venous cannulation. Appropriately trained and experienced operators add significantly to diminished patient morbidity related to venous access procedures. We discuss a patient who required an arterial stent-graft to prevent arterial hemorrhage following inadvertent cannulation of the proximal, ventral, right subclavian artery related to unsuccessful ultrasound guided access of the subclavian vein. Case presentation During pre-operative preparation for aortic valve replacement and aorto-coronary bypass surgery an anesthetist attempted ultrasound guided venous access. The ultrasound guided attempt to access the right jugular vein failed and the ultrasound guided attempt at accessing the subclavian vein resulted in inappropriate placement of an 8.5 F sheath in the arterial system. Following angiographic imaging and specialist consultations, an arterial stent-graft was deployed in the right subclavian artery rather than perform an extensive anterior chest wall resection and dissection to extract the arterial sheath. The patient tolerated the procedure, without complication, despite occlusion of the right internal mammary artery and the right vertebral artery. There were no neurologic sequelae. There was no evidence of hemorrhage after subclavian artery sheath extraction and stent-graft implantation. Conclusion The attempted ultrasound guided puncture of the subclavian vein resulted in placement of an 8.5 F subclavian artery catheter. Entry of the catheter into the proximal subclavian artery beneath the medial clavicle, the medial first rib and the manubrium suggests that the operator, most likely, did not directly visualize the puncture needle enter the vessel with the ultrasound. The bones of the anterior chest impede the ultrasound beam and the vessels in this area would not be visible to ultrasound

  6. [Psychoprophylaxis in patients after coronary artery bypass graft operations].

    Science.gov (United States)

    Rymaszewska, Joanna; Chładzińska-Kiejna, Sylwia; Górna, Renata; Kustrzycki, Wojciech

    2004-05-01

    The paper presented problems of quality of life and psychosocial functioning of patients following coronary artery bypass grafting operations. Possibilities of psychoprophylactic effects towards these patients and its efficacy were described.

  7. Downstream anastomotic hyperplasia. A mechanism of failure in Dacron arterial grafts.

    Science.gov (United States)

    LoGerfo, F W; Quist, W C; Nowak, M D; Crawshaw, H M; Haudenschild, C C

    1983-01-01

    The precise location and progression of anastomotic hyperplasia and its possible relationship to flow disturbances was investigated in femoro-femoral Dacron grafts in 28 dogs. In 13 grafts, the outflow from the end-to-side downstream anastomosis was bidirectional (BDO), and in 15 it was unidirectional (UDO) (distally). Grafts were electively removed at intervals of two to 196 days or at the time of thrombosis. Each anastomosis and adjacent artery was perfusion-fixed and sectioned sagittally. The mean sagittal section was projected onto a digitized pad, and the total area of hyperplasia internal to the arterial internal elastic lamina and within the adjacent graft was integrated by computer. The location of the hyperplasia was compared with previously established sites of flow separation and stagnation. The observation was made that hyperplasia is significantly greater at the downstream, as compared with the upstream, anastomosis in both groups (BDO = p less than 0.001 and UDO = p less than 0.001) (analysis of variance for independent groups). Furthermore, this downstream hyperplasia was progressive with time (BDO p less than 0.01) (UDO p less than 0.01); Spearman Rank Correlation. There was no significant increase in the extent of downstream hyperplasia where flow separation was known to be greater (BDO). Five grafts failed (three BDO, two UDO), as a result of complete occlusion of the downstream anastomosis by fibrous hyperplasia. Transmission electron microscopy showed the hyperplasia to consist of collagen-producing smooth muscle cells. Anastomotic hyperplasia is significantly greater at the downstream anastomosis, is progressive with time, and is the primary cause of failure of Dacron arterial grafts in this model. Quantitative analysis of downstream anastomotic hyperplasia may be a valuable measure of the biocompatibility of Dacron grafts. Images Fig. 2. Fig. 3. Fig. 5. Fig. 6. Fig. 7. Fig. 8. PMID:6219641

  8. The effect of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures: a systematic review.

    Science.gov (United States)

    Curtis, Elizabeth; Fernandez, Ritin; Lee, Astin

    2017-07-01

    The uptake of percutaneous coronary procedures via the radial artery has increased internationally due to the decreased risk of complications and increased patient satisfaction. The increased susceptibility of the radial artery to spasm however presents a potential risk for procedural failure. Although most experts agree on the need for prophylactic medications to reduce radial artery spasm, currently there is inconsistency in literature regarding the most effective vasodilatory medication or combination of medications. The objective of this study is to identify the effectiveness of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures. This review considered studies that included participants aged 18 years and over undergoing non-emergent transradial percutaneous coronary artery procedures. This review considered studies that used vasodilating intravenous and intra-arterial medications or combinations of medications prior to commencing and during transradial coronary approaches to reduce radial artery spasm. The outcomes of interest were the incidence of radial artery spasm during percutaneous coronary procedure using objective and/or subjective measures and its effect on the successful completion of the procedure. Randomized controlled trials published in the English language between 1989 to date were considered for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. An initial search of MEDLINE, CINAHL and Scopus was undertaken, followed by a search for unpublished studies. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments. Any disagreements that arose between the reviewers were resolved through discussion. Quantitative data was extracted from papers included in the review using the

  9. Carotid disease in diabetic patients undergoing coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Shahid, M.; Abid, A.R.; Dar, M.A.; Noeman, A.; Amin, S.; Azhar, M.

    2012-01-01

    Objective: To compare the severity of carotid artery disease in diabetic and non-diabetic patients undergoing coronary artery bypass grafting. Methods: From January to June 2008, 379 patients undergoing elective coronary artery bypass surgery were preoperatively evaluated for the presence of carotid stenoses by duplex scanning. Patients were divided into two groups, Group I, 156 (41.2%) diabetic patients and Group II, 223 (58.8%) non-diabetic patients. Results: There were 314 (82.8%) males and 65 (17.2%) females with a mean age of 57.2+-9.1 years. In diabetic group there were 125 (80.1%) males and 31 (19.9%) females with a mean age of 56.3+-8.9 years. Left main stem stenosis was present in 59 (37.8%) diabetics and 45 (20.2%) non-diabetics (p 70% stenosis was present in 20 (5.3%) with 13 (8.3%) diabetics and 7 (3.1%) non-diabetics (p<0.025). Stenosis of 50-70% was observed in 30 (7.9%) of which 17 (10.9%) were diabetics and 13 (5.8%) were non-diabetics. Conclusion: Presence of diabetes mellitus is associated with diffuse coronary artery disease and significant carotid artery disease in patients undergoing coronary artery bypass grafting. (author)

  10. [Coronary subclavian steal syndrome: two cases after coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Penninga, L.; Damgaard, S.

    2008-01-01

    Reverse flow in the internal mammary artery (IMA) graft due to stenosis or occlusion of the proximal ipsilateral subclavian artery causes coronary subclavian steal syndrome (CSSS). We describe two patients who were diagnosed with CSSS following CABG. Patient A presented with angina pectoris...

  11. Pancreatitis-Associated Splenic Artery Pseudoaneurysm: Endovascular Treatment with Self-Expandable Stent-Grafts

    International Nuclear Information System (INIS)

    Brountzos, Elias N.; Vagenas, Kostantinos; Apostolopoulou, Sotiria C.; Panagiotou, Irene; Lymberopoulou, Dimitra; Kelekis, Dimitrios A.

    2003-01-01

    We present a patient with a splenic arterypseudoaneurysm (SAPA) treated with placement of self-expandable stent-grafts. The procedure was complicated by stent-graft migration,but successful management resulted in lasting exclusion of the SAPA,while the patency of the splenic artery was preserved. This is the first report of self-expandable stent-graft treatment of SAPA

  12. Arteriovenous fistula of the superior gluteal artery as a complication of posterior iliac crest bone graft harvesting: 3D-CT angiography and arterial embolization

    OpenAIRE

    Kong, Chae-Gwan; Park, Jong-Beom; Won, Yoo-Dong; Riew, K. Daniel

    2009-01-01

    Superior gluteal artery injuries are rare, but potentially serious complications that occur during posterior iliac crest bone graft harvesting. The authors reported an arteriovenous fistula of the superior gluteal artery, which occurred as a complication during posterior iliac crest bone graft harvesting and was diagnosed with 3D-CT angiography, then treated with arterial embolization.

  13. Angiographic Evaluation of Carotid Artery Grafting with Prefabricated Small-Diameter, Small-Intestinal Submucosa Grafts in Sheep

    International Nuclear Information System (INIS)

    Pavcnik, Dusan; Obermiller, Josef; Uchida, Barry T.; Van Alstine, William; Edwards, James M.; Landry, Gregory J.; Kaufman, John A.; Keller, Frederick S.; Roesch, Josef

    2009-01-01

    The purpose of this study was to report the longitudinal angiographic evaluation of prefabricated lyophilized small-intestinal submucosa (SIS) grafts placed in ovine carotid arteries and to demonstrate a variety of complications that developed. A total of 24 grafts, 10 cm long and 6 mm in diameter, were placed surgically as interposition grafts. Graft patency at 1 week was evaluated by Doppler ultrasound, and angiography was used for follow-up at 1 month and at 3 to 4 months. A 90% patency rate was found at 1 week, 65% at 1 month, and 30% at 3 to 4 months. On the patent grafts, angiography demonstrated a variety of changes, such as anastomotic stenoses, graft diffuse dilations and dissections, and aneurysm formation. These findings have not been previously demonstrated angiographically by other investigators reporting results with small-diameter vessel grafts made from fresh small-intestinal submucosa (SIS). The complications found were partially related to the graft construction from four SIS layers. Detailed longitudinal angiographic study should become an essential part of any future evaluation of small-vessel SIS grafting.

  14. Endovascular repair of an innominate artery pseudoaneurysm using the Valiant Mona LSA branched graft device

    Directory of Open Access Journals (Sweden)

    Josh A. Sibille, MD

    2017-03-01

    Full Text Available A 60-year-old woman involved in a motor vehicle collision presented with a traumatic pseudoaneurysm of the innominate artery origin in addition to multiple concomitant injuries. She was classified as a high-risk candidate for open repair. An experimental thoracic branched graft device was used for coverage of the injury with the addition of a right carotid-to-left carotid-to-left subclavian artery bypass. Follow-up imaging showed resolution of the pseudoaneurysm and patency of her bypass grafts. This is the first described use of the Mona LSA Branch Thoracic Stent Graft System (Medtronic, Minneapolis, Minn in the innominate artery.

  15. Anterior ischemic optic neuropathy after conventional coronary artery bypass graft surgery.

    Science.gov (United States)

    Dorecka, Mariola; Miniewicz-Kurkowska, Joanna; Romaniuk, Dorota; Gajdzik-Gajdecka, Urszula; Wójcik-Niklewska, Bogumiła

    2011-06-01

    Perioperative optic neuropathy is a disease which can lead to serious, irreversible damage of vision. This complication could be the result of non-ocular surgery, for example, cardiac or spinal procedures. We present a case of anterior ischemic neuropathy (AION) which occurred following a conventional coronary artery bypass graft procedure. A 57-year-old man, 4 days after Conventional Coronary Artery Bypass Graft surgery as result of multi-vessel stabile coronary artery disease and history of anterolateral wall myocardial infarction, was admitted to the Eye Clinic due to significant loss of vision in his right eye. The patient had hypertension and was a heavy smoker. On admission, the slit lamp examination revealed a relative afferent pupillary defect in the right eye. The fundus examination showed optic disc edema with the presence of flame hemorrhages. Best corrected visual acuity (BCVA) was 0.02. The results of eye examination and fluorescein angiography confirmed the diagnosis of AION. Anti-aggregation and antithrombotic treatment was continued with steroids and vasodilators. After 7 days of this treatment we noticed the improvement of BCVA to 0.2. At 6-month follow-up, the vision was stable, and fundus examination revealed optic disc atrophy. After cardiac surgical operations, such as coronary artery bypass graft procedures, anterior ischemic optic neuropathy may occur. In those cases, close cooperation between the various specialists is necessary.

  16. Early results of coronary artery bypass grafting with coronary endarterectomy for severe coronary artery disease

    Directory of Open Access Journals (Sweden)

    Toischer Karl

    2009-09-01

    Full Text Available Abstract Background Despite the existence of controversial debates on the efficiency of coronary endarterectomy (CE, it is still used as an adjunct to coronary artery bypass grafting (CABG. This is particularly true in patients with endstage coronary artery disease. Given the improvements in cardiac surgery and postoperative care, as well as the rising number of elderly patient with numerous co-morbidities, re-evaluating the pros and cons of this technique is needed. Methods Patient demographic information, operative details and outcome data of 104 patients with diffuse calcified coronary artery disease were retrospectively analyzed with respect to functional capacity (NYHA, angina pectoris (CCS and mortality. Actuarial survival was reported using a Kaplan-Meyer analysis. Results Between August 2001 and March 2005, 104 patients underwent coronary artery bypass grafting (CABG with adjunctive coronary endarterectomy (CE in the Department of Thoracic-, Cardiac- and Vascular Surgery, University of Goettingen. Four patients were lost during follow-up. Data were gained from 88 male and 12 female patients; mean age was 65.5 ± 9 years. A total of 396 vessels were bypassed (4 ± 0.9 vessels per patient. In 98% left internal thoracic artery (LITA was used as arterial bypass graft and a total of 114 vessels were endarterectomized. CE was performed on right coronary artery (RCA (n = 55, on left anterior descending artery (LAD (n = 52 and circumflex artery (RCX (n = 7. Ninety-five patients suffered from 3-vessel-disease, 3 from 2-vessel- and 2 from 1-vessel-disease. Closed technique was used in 18%, open technique in 79% and in 3% a combination of both. The most frequent endarterectomized localization was right coronary artery (RCA = 55%. Despite the severity of endstage atherosclerosis, hospital mortality was only 5% (n = 5. During follow-up (24.5 ± 13.4 months, which is 96% complete (4 patients were lost caused by unknown address 8 patients died (cardiac

  17. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University, Department of Radiology, School of Medicine (Turkey); Güney, Bünyamin [Muğla Sıtkı Kocman University, Department of Radiology, School of Medicine (Turkey)

    2016-09-15

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  18. Use of a Stent Graft for Bleeding Hepatic Artery Pseudoaneurysm Following Pancreaticoduodenectomy

    Directory of Open Access Journals (Sweden)

    Leoncio L. Kaw, Jr

    2006-10-01

    Full Text Available Although uncommon, bleeding following pancreaticoduodenectomy is associated with high mortality. Management generally includes surgical reexploration or, alternatively, transarterial embolization. We report the case of a 62-year-old man who presented with massive upper gastrointestinal bleeding 3 weeks after pancreaticoduodenectomy. Selective coeliac angiography revealed a large pseudoaneurysm involving the proper hepatic artery. This was treated successfully with a stent graft. There was no recurrence of bleeding at the 6-month follow-up. To our knowledge, this is the first report of stent graft repair of bleeding hepatic artery pseudoaneurysm following pancreaticoduodenectomy.

  19. Hyperhomocysteinemia in bilateral anterior ischemic optic neuropathy after conventional coronary artery bypass graft: a case report.

    Science.gov (United States)

    Niro, A; Sborgia, G; Sborgia, A; Alessio, G

    2018-01-17

    The incidence of anterior ischemic optic neuropathy after coronary artery bypass graft procedures ranges from 1.3 to 0.25%. The mechanisms of anterior ischemic optic neuropathy after cardiovascular procedures remain undefined but many systemic and related-to-surgery risk factors could underlie anterior ischemic optic neuropathy. In this case, we report a rare presentation of a bilateral anterior ischemic optic neuropathy after coronary artery bypass graft and speculate on the preoperative hyperhomocysteinemia as an independent risk factor for anterior ischemic optic neuropathy. A 56-year-old white man, a tobacco smoker with type 2 diabetes and coronary artery disease, underwent a conventional coronary artery bypass graft with extracorporeal circulation. In spite of ongoing anti-aggregation, antithrombotic, and vasodilator therapy, 10 days after the surgery he complained of severe bilateral visual loss. Funduscopy and fluorescein angiography revealed a bilateral anterior ischemic optic neuropathy. Analysis of preoperative laboratory tests revealed hyperhomocysteinemia. Hyperhomocysteinemia could increase the risk of ocular vascular damage and bilateral ocular involvement in patients who have undergone conventional coronary artery bypass graft.

  20. A comparison of direct technique with the liquid stylet technique of radial artery cannulation in patients presenting for coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Younus, U.; Ahmed, I.

    2012-01-01

    To compare direct technique with the liquid stylet technique of radial artery cannulation in patients undergoing coronary artery byroms grouping. We hypothesized that liquid stylet technique would lead to fewer attempts and save vital time. Study Design: Randomized controlled Trial (RCT). Place and Duration of Study: Department of Anaesthesia and Intensive Care, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, [AFIC-NIHD] Rawalpindi, between 1 July 2007 to 31 Dec 2007. Patients and Methods: One hundred patients of either sex scheduled for CABG were included and were randomized to 2 groups using random number table. Fifty patients in the direct technique group and 50 in the liquid stylet group. Results: These two groups comparable with respect to age, gender and weight were studied. The number of attempts in group 1 were 1.7+-0.5 vs 3.6+-1.6 in groups 2, (p=0.021). The time consumed in group was 3.3 +- 2.2 minutes while in groups 2 it was 8.0 +- 3.6 (p=0.022). Conclusion: We concluded that the liquid stylet technique is safe, quick and is associated with lesser number of attempts at cannulation. Secondly it can be done without fancy guide wires and other technology especially in a developing country like Pakistan. (author)

  1. Effects of massage therapy on sleep quality after coronary artery bypass graft surgery.

    Science.gov (United States)

    Nerbass, Flavia Baggio; Feltrim, Maria Ignez Zanetti; Souza, Silvia Alves de; Ykeda, Daisy Satomi; Lorenzi-Filho, Geraldo

    2010-01-01

    Having poor sleep quality is common among patients following cardiopulmonary artery bypass graft surgery. Pain, stress, anxiety and poor sleep quality may be improved by massage therapy. This study evaluated whether massage therapy is an effective technique for improving sleep quality in patients following cardiopulmonary artery bypass graft surgery. Participants included cardiopulmonary artery bypass graft surgery patients who were randomized into a control group and a massage therapy group following discharge from the intensive care unit (Day 0), during the postoperative period. The control group and the massage therapy group comprised participants who were subjected to three nights without massage and three nights with massage therapy, respectively. The patients were evaluated on the following mornings (i.e., Day 1 to Day 3) using a visual analogue scale for pain in the chest, back and shoulders, in addition to fatigue and sleep. Participants kept a sleep diary during the study period. Fifty-seven cardiopulmonary artery bypass graft surgery patients were enrolled in the study during the preoperative period, 17 of whom were excluded due to postoperative complications. The remaining 40 participants (male: 67.5%, age: 61.9 years ± 8.9 years, body mass index: 27.2 kg/m² ± 3.7 kg/m²) were randomized into control (n = 20) and massage therapy (n = 20) groups. Pain in the chest, shoulders, and back decreased significantly in both groups from Day 1 to Day 3. The participants in the massage therapy group had fewer complaints of fatigue on Day 1 (p=0.006) and Day 2 (p=0.028) in addition, they reported a more effective sleep during all three days (p=0.019) when compared with the participants in the control group. Massage therapy is an effective technique for improving patient recovery from cardiopulmonary artery bypass graft surgery because it reduces fatigue and improves sleep.

  2. Fingertip Replantation Using Y-Shaped Vein Graft to Pulp Artery.

    Science.gov (United States)

    Kim, Jun Hyuk; Lee, Young Man

    2015-10-01

    Re-establishing adequate venous outflow is the most important factor for success of fingertip replantation. However, in zone I level, replantation is very difficult, especially in repairing venous circulation. The authors have made an attempt to replantation using Y-shaped vein (YSV) graft to identify and repair veins easily in fingertip replantation. From January 2007 to December 2012, a total of 46 fingertip replantations in 44 consecutive patients with amputations in the Tamai zone I level were performed by using YSV graft. In all patients, arterial anastomosis was performed using YSV graft, and interpositional vein grafts were used for venous repair. The overall success rate of the YSV-grafted replantations was 91.3% (42/46). Postoperative vascular complications occurred in 6 YSV-grafted replantations (13%), and pulp atrophy in the YSV-grafted digits was 9.5% (4/42). Fingertip replantation in zone I level is a difficult territory to a microsurgeon, especially anastomosing veins. However, our YSV grafting technique has shown value in this setting, enabling better esthetic and functional results.

  3. Diagnostic value of myocardial perfusion SPECT in the prediction of restenosis after coronary artery bypass graft surgery

    International Nuclear Information System (INIS)

    Paeng, J. C.; Lee, D. S.; Kang, W. J.; Kim, K. B.; Chung, J. K.; Lee, M. C.

    2002-01-01

    Myocardial SPECT has been reported to be sensitive in the detection of restenosis after revascularization. However, the diagnostic value is not well established in bypass graft surgery (CABG), due to significant influences of characteristics of graft vessels and the time interval between CABG and the SPECT. In this study, we evaluated the diagnostic value of myocardial SPECT for the restenosis after CABG. A total of 160 patients with coronary artery disease (M:F=118:42, 60±8 yr) who had undergone CABG were included. Rest T1-201/ dipyridamole stress Tc-99m-MIBI SPECT was performed 3 months (103±16 days) after CABG. Segmental perfusion was quantified using a 20-segment model, and segments of reversible perfusion defect (REV) were defined. Follow-up coronary angiography was performed 1 year (397±104 days) after CABG. The segments of REV were compared between arterial and venous graft groups. And the diagnostic power of 3-month SPECT was evaluated for the prediction of restenosis. On the 3-month SPECT, 620 segments showed REV. The segments of REV were 37% of artery-grafted segments and 36% of vein-grafted segments (p=n.s.). On 1-year coronary angiography, 113 graft vessels (28%) showed restenosis. The overall sensitivity and specificity of REV on 3-month SPECT for the prediction of restenosis were 46% and 67%, respectively, but 52% and 68%, in artery-graft group. REV detected on 3-month SPECT has a predictive value, especially, high specificity for the prediction of restenosis after CABG, which was more definite in artery-graft group

  4. The management of impending myocardial infarction using coronary artery by-pass grafting and an intra-aortic balloon pump.

    Science.gov (United States)

    Harris, P L; Woollard, K; Bartoli, A; Makey, A R

    1980-01-01

    Of 33 patients with impending myocardial infarction 25 were treated using a combination of coronary artery by-pass grafting and intra-aortic balloon pumping. Eight patients were treated with coronary artery by-pass grafting alone. Twenty-two of the 25 patients who were treated with the combined technique made a full recovery. Three patients sustained definite myocardial infarctions and one of these died. Five of the 8 patients treated by grafting alone suffered infarction and of these 3 died. The value of intra-aortic balloon pumping in combination with coronary artery by-pass grafting in the management of impending myocardial infarction is discussed.

  5. Stent-Graft Repair of a Large Cervical Internal Carotid Artery Pseudoaneurysm Causing Dysphagia

    International Nuclear Information System (INIS)

    Gupta, Vivek; Niranjan, Khandelwal; Rawat, Lokesh; Gupta, A. K.

    2009-01-01

    Pseudoaneurysms of the cervical internal carotid artery (ICA) are rare and most frequently result from trauma, infection, or sometimes spontaneously. They have the potential to cause life-threatening hemorrhage; thus, their immediate management is necessary. Endovascular treatment by stent graft placement in the affected artery appears to be a safe and effective treatment option. We present a case of a child who presented with neck swelling and dysphagia caused by a ruptured cervical ICA pseudoaneurysm which was managed by stent graft placement.

  6. Cephalic pancreaticoduodenectomy with preservation of a right coronary artery bypass graft using the right gastro-epiploic artery: a case report.

    Science.gov (United States)

    Homsy, K; Paquay, J-L; Farghadani, H

    2018-02-20

    Pancreatic cancer is a rare disease with a high mortality rate, for which complete surgical resection, when possible, is the preferred therapeutic. Pancreaticoduodenectomy represents the surgical technique of choice. Abdominal surgeons can be faced with the challenge of patients with a history of coronary artery bypass graft in which the right gastro-epiploic artery is used. We report the case of a patient with an adenocarcinoma of the pancreatic head, stage IIA, having previously undergone a triple coronary artery bypass, one of which being a right gastro-epiploic graft. Our challenge was underlined by the necessity of a complete oncological resection through a cephalic pancreaticoduodenectomy while preserving the necessary cardiac perfusion via the right gastro-epiploic artery. We have been able to preserve a right gastro-epiploic artery as a coronary bypass during a cephalic pancreaticoduodenectomy for a cephalic pancreatic adenocarcinoma. We have successfully been able to preserve and re-implant the right gastro-epiploic artery to the origin of the gastroduodenal artery while insuring R0 resection of the tumor. A coronary artery bypass using the right gastro-epiploic artery should therefore not be considered as an obstacle to a Whipple's procedure if total oncological resection is obtainable.

  7. Early evaluation of coronary artery bypass grafts: CT or selective angiography

    International Nuclear Information System (INIS)

    Wilson, P.C.; Gutierrez, O.; Moss, A.

    1984-01-01

    A prospective study was performed in 27 patients to compare the value of computed tomography and selective angiography in assessing coronary artery graft patency in the early post-operative period. The sensitivity of CT to graft patency was 85% with no falsely patent determinations. Dynamic CT was not found useful in predicting graft stenosis. There were no complications associated with CT studies, and two related to selective angiography. It is concluded that CT is the procedure of choice for graft evaluation in the early post-operative period; but that angiography is mandatory for the assessment of late symptom recurrence. A review is made of the results described in previous series. (orig.)

  8. Morphology and function of dog arterial grafts preserved in UW-solution

    NARCIS (Netherlands)

    Vischjager, M.; van Gulik, T. M.; Pfaffendorf, M.; van Zwieten, P. A.; van Marle, J.; Kromhout, J. G.; Klopper, P. J.; Jacobs, M. J.

    1995-01-01

    To assess the function of arterial grafts after prolonged preservation in the University of Wisconsin solution (UW), in vitro and in vivo. Carotid arteries were harvested from dogs and stored for 1-21 days at 4 degrees C in UW (n = 10) or in PBS (0.9% NaCl, pH 7.4), (PBS) (n = 10). Slices were

  9. Combined Radial-Pedal Access Strategy and Radial-Pedal Rendezvous in the Revascularization of Complex Total Occlusions of the Superficial Femoral Artery (the "No Femoral Access" Strategy).

    Science.gov (United States)

    Hanna, Elias B; Prout, Davey L

    2016-04-01

    To describe the combined use of radial-pedal access for recanalization of complex superficial femoral artery (SFA) occlusions unsuitable for transfemoral recanalization. Patients are selected for this strategy if they have a long (≥ 10 cm) SFA occlusion with unfavorable aortoiliac anatomy, an absent ostial stump, or severely diseased and calcified distal reconstitution. Left radial artery and distal anterior or posterior tibial artery are accessed with 6-F and 4-F sheaths, respectively. The SFA lesion is crossed retrogradely with a 0.035-inch wire system. If retrograde crossing is not immediately successful, transradial subintimal tracking and radial-pedal subintimal rendezvous are used to allow retrograde reentry. Fifteen patients (mean age 62 ± 5 years; 11 men) have been treated in this fashion, and frequently stented, through the tibiopedal access. Seven patients required radial-pedal rendezvous to facilitate retrograde reentry. Two patients underwent transradial iliac stenting during the same session, and 1 patient underwent transradial kissing angioplasty of the profunda. No major complication occurred in any patient. After the procedure, the pulse across the accessed tibial artery was palpable in all patients. In patients with long and complex SFA occlusion unsuitable for transfemoral recanalization, a radial-pedal strategy can overcome revascularization obstacles. © The Author(s) 2016.

  10. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  11. New parameter of the right gastroepiploic arterial graft using the power spectral analysis device named MemCalc soft.

    Science.gov (United States)

    Uehara, Mayuko; Takagi, Nobuyuki; Muraki, Satoshi; Yanase, Yosuke; Tabuchi, Masaki; Tachibana, Kazutoshi; Miyaki, Yasuko; Ito, Toshiro; Higami, Tetsuya

    2015-12-01

    Transit-time flow measurement (TTFM) parameters such as mean graft flow (MGF, ml/min), pulsatility index (PI) and diastolic filling (DF, %) have been extensively researched for internal mammary arterial or saphenous vein grafts. In our experience of using the right gastroepiploic arterial (GEA) graft for right coronary artery (RCA) grafting, we observed unique GEA graft flow waveforms. We analysed the GEA graft flow waveforms for their effectiveness in determining GEA graft patency by power spectral analysis. Forty-five patients underwent off-pump coronary artery bypass using the GEA graft for RCA grafting individually. The means of intraoperative MGF, PI and DF were compared between patent and non-patent grafts, postoperatively. Furthermore, the GEA flow data were output and analysed using power spectral analysis. Forty grafts were 'patent' and five were 'non-patent'. There were no significant differences in the mean TTFM parameters between the patent and non-patent grafts (MGF: 22 vs 8 ml/min, respectively, P = 0.068; PI: 3.5 vs 6.5, respectively, P = 0.155; DF: 63 vs 53%, respectively, P = 0.237). Results of the power spectral analysis presented clear differences; the power spectral density (PSD) of patent grafts presented high peaks at frequency levels of 1, 2 and 3 Hz, and the non-patent graft PSD presented high peaks that were not limited to these frequencies. The PSD had a sensitivity and specificity of 80 and 87.5%, respectively. Power spectral analysis of the GEA graft flow is useful to distinguish between non-patent and patent grafts intraoperatively. This should be used as a fourth parameter along with MGF, PI and DF. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  12. Local immobilization of the left anterior descending artery for minimally invasive coronary bypass grafting

    NARCIS (Netherlands)

    Boonstra, PW; Grandjean, JG; Mariani, MA

    We describe a device for coronary artery stabilization during minimally invasive coronary artery bypass grafting performed without cardiopulmonary bypass via a small (8 to 10 cm) left anterolateral thoracotomy. This device facilitates the anastomosis of the left internal mammary artery to the left

  13. Exclusive use of arterial grafts in coronary artery bypass operations for three-vessel disease : Use of both thoracic arteries and the gastroepiploic artery in 256 consecutive patients

    NARCIS (Netherlands)

    Grandjean, JG; Voors, AA; Boonstra, PW; denHeyer, P; Ebels, T

    1996-01-01

    Methods: From September 1989 to September 1994 we operated on a consecutive group of 256 patients with three-vessel disease in whom we used the right gastroepiploic artery together with both internal thoracic arteries, Vein grafts were not used in these patients, This population consisted of 233 men

  14. Value of magnetic resonance imaging for the noninvasive detection of stenosis in coronary artery bypass grafts and recipient coronary arteries

    NARCIS (Netherlands)

    Langerak, Susan E.; Vliegen, Hubert W.; Jukema, J. Wouter; Kunz, Patrik; Zwinderman, Aeilko H.; Lamb, Hildo J.; van der Wall, Ernst E.; de Roos, Albert

    2003-01-01

    BACKGROUND: Magnetic resonance imaging (MRI) is a potential noninvasive diagnostic tool to detect coronary artery bypass graft stenosis, but its value in clinical practice remains to be established. We investigated the value of MRI in detecting stenotic grafts, including recipient vessels. METHODS

  15. Complications and nursing care in interventional treatment of diabetic foot via radial artery access

    International Nuclear Information System (INIS)

    Liu Lingyun; Zhou Xiaoxiang; Zeng Yongmei; Chen Junfei; Lai Lisha; Pang Pengfei; Zhu Kangshun

    2009-01-01

    Objective: To evaluate the therapeutic effect of interventional treatment via radial artery access for diabetic foot and to summarize its complications and nursing care. Methods: The interventional treatment via radial artery access was performed in twenty patients with diabetic foot. The preoperative psychological nursing care, the nursing of the punctured site of radial artery and the indwelling catheter, the complications of the puncture site and thrombolytic therapy were reviewed and retrospectively analyzed. Results: Some complications occurred in eight cases, including hematoma at puncture site (n= 1), oozing of blood (n=3), gingival bleeding (n=1) and pain (n=3). No retention of urine or infection occurred. Conclusion: It is very important to pay enough attention to the nursing care of puncture site and indwelling catheter sheath and to make a close observation of patient's condition in order to reduce the occurrence of complications. Rich clinical experience and careful observation after the operation can definitely reduce the occurrence of thrombolytic complications and improve the patient's living quality. (authors)

  16. Evaluación de hipertensos en base a registros de variación de diámetro arterial radial Evaluation of hypertensive patients by radial arterial diameter variation recording

    Directory of Open Access Journals (Sweden)

    Fernando M. Clara

    2006-12-01

    Full Text Available Se utilizó la técnica de análisis del registro incruento de las variaciones de diámetro de arteria radial para evaluar el deterioro arterial y el riesgo cardiovascular en pacientes hipertensos. El transductor utilizado consistió en un sensor de movimiento apoyado sobre la zona de palpación del pulso radial. Se efectuó la determinación del índice de aumentación radial, un parámetro que cuantifica la magnitud de las reflexiones de la onda de presión en la región aórtica, sobre un conjunto de 47 hipertensos, y se lo comparó con otro estudio similar efectuado sobre 81 normotensos sanos. Estos últimos presentaron menores valores de dicho índice, pero al avanzar la edad los valores de ambos grupos tendieron a coincidir. Esto fue confirmado al comparar morfológicamente los registros de ambos grupos, hallándose que los registros de ancianos normotensos sanos e hipertensos de edades similares resultaron visiblemente parecidos. Se halló también que determinados hipertensos jóvenes presentaron ciertas características morfológicas similares a las de normotensos de la misma edad, indicando que aún conservaban las características elásticas propias de su grupo etario. Los resultados fueron similares a los logrados sobre registros de presión arterial radial obtenidos mediante tonometría de aplanación, utilizándose una tecnología disponible en nuestro medio y de menor costo.A blood less analysis technique of the diameter variation signal at radial artery was used to evaluate the arterial disease and the cardiovascular risk in hypertensive patients. A movement transducer was used to record the wrist pulse. A radial augmentation index was proposed to quantify the magnitude of the pressure wave reflections in the aortic region. The experiment was carried out with a group of 47 hypertensive men and compared with a similar study performed on 81 normotensive healthy men. The last ones presented smaller values of this index, but as age

  17. Retrograde CTO-PCI of Native Coronary Arteries Via Left Internal Mammary Artery Grafts: Insights From a Multicenter U.S. Registry.

    Science.gov (United States)

    Tajti, Peter; Karatasakis, Aris; Karmpaliotis, Dimitri; Alaswad, Khaldoon; Jaffer, Farouc A; Yeh, Robert W; Patel, Mitul; Mahmud, Ehtisham; Choi, James W; Doing, Anthony H; Toma, Catalin; Uretsky, Barry; Garcia, Santiago; Moses, Jeffrey W; Parikh, Manish; Kirtane, Ajay; Ali, Ziad A; Hatem, Raja; Karacsonyi, Judit; Danek, Barbara A; Rangan, Bavana V; Banerjee, Subhash; Ungi, Imre; Brilakis, Emmanouil S

    2018-03-01

    Retrograde percutaneous coronary intervention (PCI) of native coronary artery chronic total occlusion (CTO) via left internal mammary artery (LIMA) graft has received limited study. We compared the clinical and procedural characteristics and outcomes of retrograde CTO-PCI through LIMA grafts vs other conduits in a contemporary multicenter CTO registry. The LIMA was used as the collateral channel in 20 of 990 retrograde CTO-PCIs (2.02%) performed at 18 United States centers. The mean age of the study patients was 69 ± 7 years and 95% were men. The most common CTO target vessel was the right coronary artery (55%). The mean J-CTO score in the LIMA group was high (3.45 ± 0.76). The technical success rates were 70% for retrograde PCI via LIMA graft vs 81.05% for retrograde via other conduits (P=.25), while procedural success rates were 70% for retrograde PCI via LIMA graft and 78.19% for retrograde via other conduits (P=.41). The incidence of major in-hospital complications was also similar between the LIMA and non-LIMA retrograde groups (5% vs 6%; P>.99). Use of guide-catheter extensions (40% vs 28%; P=.22), intravascular ultrasound (45% vs 31%; P=.20), and left ventricular assist devices (24% vs 10%; P=.08) was numerically higher in retrograde CTO-PCIs via LIMA grafts. Retrograde CTO-PCI is infrequently performed via LIMA grafts and is associated with similar success and major in-hospital complication rates as retrograde CTO-PCI performed via other conduits.

  18. Prediction of coronary artery bypass graft flow

    International Nuclear Information System (INIS)

    Tamiya, Eiji; Hada, Yoshiyuki; Asano, Ken-ichi; Iio, Masahiro.

    1991-01-01

    To predict the coronary artery bypass graft (CABG) flow based on the time density curve (TDC) obtained from the digital subtraction aortograms (DSA), we developed a pulsatile CABG model (perfusion pressure 60,130 mmHg, pulse rate 53,126/min, cardiac output 3-7 l/min, diameter of the graft 2.1∼6.0 mm). After positioning the regions of interest (ROI), we injected contrast medium(5∼40 ml/sec, 5∼40 ml) into the outlet conduit. Concerning the TDCs, we calculated appearance time (Ta), peak densities (Dp), peak time (Tp), disappearance time (Td), integral of TDC, ΔTp (difference of Tp between two ROI) and ΔTa (difference of Ta between two ROI). Perfusion pressure, graft flow and output curve were similar to those of patients with CABG. Ta, Tp, Td, and ΔTp were affected by both the injection rate and the volume of the contrast medium; while Dp and the TDC integral were only affected by the latter parameter. Under the same conditions of contrast medium injection, the TDC depended strongly on graft flow, diameter of the graft, output and pulse rate. 21.6+0.92π·d 2 /4·Δ1/ΔTp·60 provided the most accurate estimation of CABG flow (r=0.865, p<0.01). We conclude that densitometric analysis of DSA may be useful in the prediction of CABG flow. (author)

  19. Endovascular Repair of Acute Symptomatic Pararenal Aortic Aneurysm With Three Chimney and One Periscope Graft for Complete Visceral Artery Revascularization

    International Nuclear Information System (INIS)

    Brechtel, Klaus; Ketelsen, Dominik; Endisch, Andrea; Heller, Stephan; Heuschmid, Martin; Stock, Ulrich A.; Kalender, Guenay

    2012-01-01

    PurposeTo describe a modified endovascular technique for complete revascularization of visceral and renal arteries in symptomatic pararenal aortic aneurysm (PRAA).TechniqueArterial access was surgically established in both common femoral arteries (CFAs) and the left subclavian artery (LSA). Revascularization of the left renal artery, the celiac trunk, and the superior mesenteric artery was performed through one single sheath via the LSA. Suitable covered stents were put in the aortic branches but not deployed. The right renal artery was accessed over the left CFA. Due to the longitudinal extension of the presented aneurysm two stent-grafts were introduced via the right CFA. After deploying the aortic stent-grafts, all covered stents in the side branches were deployed consecutively with a minimum overlap of 5 mm over the cranial and caudal stent-graft edges. Simultaneous ballooning was performed to fully expand all stent-grafts and warranty patency. Conclusion: This is the first report in the literature of chimney grafting in PRAA for complete revascularization of visceral and renal branches by using more than two covered stents introduced from one side through one single sheath. However this technique is modified, it should be used only in bailout situations when branched stent-grafts are not available and/or surgery is not suitable.

  20. Successful treatment of coronary artery pseudoaneurysm by graft stent, which developed after the implantation of bare metal stent

    Directory of Open Access Journals (Sweden)

    Utku Şenol

    2013-03-01

    Full Text Available Although coronary artery pseudoaneurysm which couldoccur following percutaneous coronary interventions is arare complication, it can be mortal. As soon as the pseudoaneurysmis diagnosed, it should be treated by percutaneousintervention or surgery. Graft stent implantationis a preferred treatment for appropriate patients. In thiscase report, we presented a successful treatment of coronaryartery pseudoaneurysm by graft stent; which developedafter the implantation of bare metal stent into theleft anterior descending coronary artery. J Clin Exp Invest2013; 4 (1: 126-129Key words: Coronary artery, pseudoaneurysm, graft stent

  1. Effects of massage therapy on sleep quality after coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Flavia Baggio Nerbass

    2010-01-01

    Full Text Available INTRODUCTION: Having poor sleep quality is common among patients following cardiopulmonary artery bypass graft surgery. Pain, stress, anxiety and poor sleep quality may be improved by massage therapy. OBJECTIVE: This study evaluated whether massage therapy is an effective technique for improving sleep quality in patients following cardiopulmonary artery bypass graft surgery. METHOD: Participants included cardiopulmonary artery bypass graft surgery patients who were randomized into a control group and a massage therapy group following discharge from the intensive care unit (Day 0, during the postoperative period. The control group and the massage therapy group comprised participants who were subjected to three nights without massage and three nights with massage therapy, respectively. The patients were evaluated on the following mornings (i.e., Day 1 to Day 3 using a visual analogue scale for pain in the chest, back and shoulders, in addition to fatigue and sleep. Participants kept a sleep diary during the study period. RESULTS: Fifty-seven cardiopulmonary artery bypass graft surgery patients were enrolled in the study during the preoperative period, 17 of whom were excluded due to postoperative complications. The remaining 40 participants (male: 67.5%, age: 61.9 years ± 8.9 years, body mass index: 27.2 kg/m² ± 3.7 kg/m² were randomized into control (n = 20 and massage therapy (n = 20 groups. Pain in the chest, shoulders, and back decreased significantly in both groups from Day 1 to Day 3. The participants in the massage therapy group had fewer complaints of fatigue on Day 1 (p=0.006 and Day 2 (p=0.028 in addition, they reported a more effective sleep during all three days (p=0.019 when compared with the participants in the control group. CONCLUSION: Massage therapy is an effective technique for improving patient recovery from cardiopulmonary artery bypass graft surgery because it reduces fatigue and improves sleep.

  2. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    Directory of Open Access Journals (Sweden)

    Min-Ho Jun

    2016-05-01

    Full Text Available The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

  3. Arterial grafts exhibiting unprecedented cellular infiltration and remodeling in vivo: the role of cells in the vascular wall.

    Science.gov (United States)

    Row, Sindhu; Peng, Haofan; Schlaich, Evan M; Koenigsknecht, Carmon; Andreadis, Stelios T; Swartz, Daniel D

    2015-05-01

    To engineer and implant vascular grafts in the arterial circulation of a pre-clinical animal model and assess the role of donor medial cells in graft remodeling and function. Vascular grafts were engineered using Small Intestinal Submucosa (SIS)-fibrin hybrid scaffold and implanted interpositionally into the arterial circulation of an ovine model. We sought to demonstrate implantability of SIS-Fibrin based grafts; examine the remodeling; and determine whether the presence of vascular cells in the medial wall was necessary for cellular infiltration from the host and successful remodeling of the implants. We observed no occlusions or anastomotic complications in 18 animals that received these grafts. Notably, the grafts exhibited unprecedented levels of host cell infiltration that was not limited to the anastomotic sites but occurred through the lumen as well as the extramural side, leading to uniform cell distribution. Incoming cells remodeled the extracellular matrix and matured into functional smooth muscle cells as evidenced by expression of myogenic markers and development of vascular reactivity. Interestingly, tracking the donor cells revealed that their presence was beneficial but not necessary for successful grafting. Indeed, the proliferation rate and number of donor cells decreased over time as the vascular wall was dominated by host cells leading to significant remodeling and development of contractile function. These results demonstrate that SIS-Fibrin grafts can be successfully implanted into the arterial circulation of a clinically relevant animal model, improve our understanding of vascular graft remodeling and raise the possibility of engineering mural cell-free arterial grafts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. GuideLiner™ as guide catheter extension for the unreachable mammary bypass graft.

    Science.gov (United States)

    Vishnevsky, Alec; Savage, Michael P; Fischman, David L

    2018-03-09

    Percutaneous coronary intervention (PCI) of mammary artery bypass grafts through a trans-radial (TR) approach can present unique challenges, including coaxial vessel engagement of the guiding catheter, adequate visualization of the target lesion, sufficient backup support for equipment delivery, and the ability to reach very distal lesions. The GuideLiner catheter, a rapid exchange monorail mother-in-daughter system, facilitates successful interventions in such challenging anatomy. We present a case of a patient undergoing PCI of a right internal mammary artery (RIMA) graft via TR access in whom the graft could not be engaged with any guiding catheter. Using a balloon tracking technique over a guidewire, a GuideLiner was placed as an extension of the guiding catheter and facilitated TR-PCI by overcoming technical challenges associated with difficult anatomy. © 2018 Wiley Periodicals, Inc.

  5. [Digital necrosis in a patient with anorexia nervosa. Association of vasculopathy and radial artery injury].

    Science.gov (United States)

    Launay, D; Queyrel, V; Hatron, P Y; Michon-Pasturel, U; Hachulla, E; Devulder, B

    2000-11-13

    Patients with anorexia nervosa can develop distal vasculopathy sometimes leading to severe Raynaud's phenomenon or acrocyanosis. We report a cas of anorexia nervosa-related vasculopathy associated with iatrogenic injury to the radial artery that led to digital necrosis. An 18-year-old woman, with a history of severe anorexia nervosa of 5 years duration and who acknowledged regular use of tobacco and cannabis, was hospitalized for necrosis of the left index and thumb that had occurred shortly after left radial artery puncture for blood gas analysis. Acrocyanosis of the 4 limbs had been present since the onset of anorexia nervosa. Arteriography of the upper limbs showed major spasm of the left radial and cubital arteries and thromboses in the left interdigital arteries of the left index and thumb. The distal portions of the arteries were then on the left and on the right. The nectrotic lesions healed after intravenous administration of ilomedine and interruption of tobacco and cannabis. Acrocyanosis of the four limbs persisted. We report a case of digital necrosis occurring after arterial puncture for blood gas analysis in a patient with a vascular bed weakened by tobacco and cannabis intoxication but also by anorexia nervosa-related vasculopathy. This observation underlines the potentially dangerous nature of invasive intravascular procedures in this context. Indications for vessel puncture must be assessed with prudence.

  6. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: early results.

    Science.gov (United States)

    Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong

    2012-11-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft

  7. Restoration of Failed Renal Graft Function After Successful Angioplasty of Pressure-Resistant Renal Artery Stenosis Using a Cutting Balloon: A Case Report

    International Nuclear Information System (INIS)

    Peregrin, J. H.; Buergelova, M.

    2009-01-01

    This study is the report of a 37-year-old male with a transplanted kidney from a 3.5-year-old donor: the graft had two arteries transplanted with an aortic patch to an external iliac artery. Four months after transplantation, the graft function deteriorated, together with the development of hypertension. Stenosis of both graft arteries was detected and the patient was referred for angioplasty. The angiographic result was suboptimal, nevertheless, the graft function improved and was more or less stable (serum creatinine, 160-200 μmol/l) for 4 years, along with persistently difficult-to-control hypertension. Five years after transplantation, the graft function deteriorated again and severe graft artery restenosis was detected. The restenosis did not respond to dilatation, graft function failed, hypertension decompensated, and left ventricular failure developed. The patient required dialysis. A cutting balloon angioplasty opened the artery, and kidney function was restored after a few days: the serum creatinine level dropped to 140-160 μmol/l, and the glomerular filtration rate (creatinine clearance) to 0.65 ml/min/1.73 m 2 . The graft function has now been stable for more than 2 years, however, the hypertension is still difficult to control.

  8. Reliability of palpation of the radial artery compared with auscultation of the brachial artery in measuring SBP

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; van den Born, Bert-Jan H.; van Montfrans, Gert A.

    2011-01-01

    Background Systolic blood pressure contributes more to cardiovascular disease than DBP, especially in elderly persons. Palpation of the radial artery to assess SBP - Riva-Rocci's technique-may be an attractive alternative for auscultatory SBP in these patients. Therefore, we investigated the

  9. Pre-operative anxiety in patients undergoing coronary artery bypass graft surgery – A cross-sectional study

    Directory of Open Access Journals (Sweden)

    C. Ramesh

    Full Text Available Background: Coronary artery bypass graft surgery is an important treatment for the patients with coronary artery disease to reduce angina and enhance the quality of life. Anxiety is a usual reaction to a stressful situation and is existing in patients awaiting surgery. Objective: The objective of the study was to assess pre-operative anxiety in patients who were undergoing coronary artery bypass graft surgery. Methods: A cross-sectional study consisting of 140 patients undergoing coronary artery bypass graft surgery were included in the study using a convenience sampling technique in a tertiary care referral hospital. The data was collected using state-trait anxiety inventory. The data were entered into SPSS (version – 20.0 for windows and descriptive and inferential statistics were performed. Results: The study enrolled 140 (117 males and 23 females patients. Their mean age was 57.29 ± 8.14 (range 35–70 years. Most of the patients 118 (84% had preoperative anxiety before coronary artery bypass graft surgery. There was an association found between gender and anxiety with Pearson chi-square value of 11.57 (p < 0.001. Discussion: Patients undergoing coronary artery bypass graft surgery is experiencing the high level of pre-operative anxiety and females had higher anxiety than the males. Identification of the pre-operative anxiety in patients undergoing CABG surgery is essential because it helps the health professionals and nurses to develop effective and appropriate interventions. Keywords: Preoperative period, Anxiety, Coronary artery bypass, Perioperative care

  10. Off-pump coronary artery bypass grafting or percutaneous transluminal coronary angioplasty with stenting for proximal left anterior descending coronary artery disease?

    NARCIS (Netherlands)

    Drenth, Derk Jan

    2005-01-01

    This thesis describes and discusses the results of a prospective randomized controlled clinical trial comparing percutaneous coronary angioplasty with stenting (stenting) and off-pump coronary artery bypass grafting with a left internal mammary artery (surgery) in patients with a high-grade stenosis

  11. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2012-02-01

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  12. Comparison of arterial stiffness and microcirculatory changes following abdominal aortic aneurysm grafting.

    LENUS (Irish Health Repository)

    Moloney, M A

    2010-11-11

    BACKGOUND: Abdominal aortic aneurysm (AAA) surgery provides a unique opportunity to study the impact of arterial stiffness on central haemodynamics, reflected in augmentation index (AI). The aneurysmal aorta is significantly stiffer than undilated age-matched aorta. AIM: We investigated whether replacement of an aneurysmal aorta with a compliant graft would result in a decrease in AI, which would thus decrease myocardial workload parameters. METHODS: Patients undergoing elective open or endovascular AAA repair were assessed with applanation tonometry and laser fluximetry pre-operatively, immediately and long-term post-operatively. RESULTS: Replacement of a small segment of abnormal conduit vessel resulted in improvements in AI, demonstrating that arterial stiffness can be surgically manipulated. CONCLUSIONS: These results reflect a decreased myocardial workload post-aortic grafting. This decrease in AI is important from a risk factor management perspective, and arterial stiffness should become a further recognised and screened for risk factor in patients with known aneurysmal disease.

  13. Risk score for predicting long-term mortality after coronary artery bypass graft surgery.

    Science.gov (United States)

    Wu, Chuntao; Camacho, Fabian T; Wechsler, Andrew S; Lahey, Stephen; Culliford, Alfred T; Jordan, Desmond; Gold, Jeffrey P; Higgins, Robert S D; Smith, Craig R; Hannan, Edward L

    2012-05-22

    No simplified bedside risk scores have been created to predict long-term mortality after coronary artery bypass graft surgery. The New York State Cardiac Surgery Reporting System was used to identify 8597 patients who underwent isolated coronary artery bypass graft surgery in July through December 2000. The National Death Index was used to ascertain patients' vital statuses through December 31, 2007. A Cox proportional hazards model was fit to predict death after CABG surgery using preprocedural risk factors. Then, points were assigned to significant predictors of death on the basis of the values of their regression coefficients. For each possible point total, the predicted risks of death at years 1, 3, 5, and 7 were calculated. It was found that the 7-year mortality rate was 24.2 in the study population. Significant predictors of death included age, body mass index, ejection fraction, unstable hemodynamic state or shock, left main coronary artery disease, cerebrovascular disease, peripheral arterial disease, congestive heart failure, malignant ventricular arrhythmia, chronic obstructive pulmonary disease, diabetes mellitus, renal failure, and history of open heart surgery. The points assigned to these risk factors ranged from 1 to 7; possible point totals for each patient ranged from 0 to 28. The observed and predicted risks of death at years 1, 3, 5, and 7 across patient groups stratified by point totals were highly correlated. The simplified risk score accurately predicted the risk of mortality after coronary artery bypass graft surgery and can be used for informed consent and as an aid in determining treatment choice.

  14. Does extubation result in haemodynamic instability in patients following coronary artery bypass grafts?

    Science.gov (United States)

    Walthall, H; Ray, S; Robson, D

    2001-10-01

    Coronary heart disease and its management continue to be at the centre of Government health policy. The present political climate demands clinical effectiveness and best practice should be established, while maintaining the philosophy of cost-effectiveness and resource management. These directives have led practitioners to question the care of patients following coronary artery bypass surgery, in particular the role of mechanical ventilation and the subsequent act of extubation. A retrospective study of 89 patients who had coronary artery bypass grafts (emergency and elective) was undertaken, to establish if extubation had a significant effect on the haemodynamic status of patients with variable degrees of left ventricular function (19% with poor left ventricular function). The study found that extubation was achieved within a mean time of 4.97 hours following return from surgery. Extubation resulted in a significant increase in heart rate (P = 0.001), as well as a respiratory acidosis (pCO2: P = 0.000; pH: P = 0.000). However, the stability of the patient was not compromised, with neither mean arterial blood pressure (P = 0.825) nor oxygenation levels (P = 0.267) being significantly altered by extubation. On multivariate analysis, the act of extubation had no significant effect on any of the dependent variables. These results suggest that it is not extubation alone that has an impact on the haemodynamic stability of patients following coronary artery bypass grafts, but that this is indeed multifactorial. Therefore extubation is 'safe' practice for patients with varying degrees of left ventricular function following coronary artery bypass grafts. Limitations of the study are acknowledged.

  15. Off-Pump Versus On-Pump Coronary Artery Bypass Grafting

    DEFF Research Database (Denmark)

    Møller, Christian H; Steinbrüchel, Daniel A

    2014-01-01

    Coronary artery bypass grafting (CABG) remains the preferred treatment in patients with complex coronary artery disease. However, whether the procedure should be performed with or without the use of cardiopulmonary bypass, referred to as off-pump and on-pump CABG, is still up for debate....... Intuitively, avoidance of cardiopulmonary bypass seems beneficial as the systemic inflammatory response from extracorporeal circulation is omitted, but no single randomized trial has been able to prove off-pump CABG superior to on-pump CABG as regards the hard outcomes death, stroke or myocardial infarction....... In contrast, off-pump CABG is technically more challenging and may be associated with increased risk of incomplete revascularization. The purpose of the review is to summarize the current literature comparing outcomes of off-pump versus on-pump coronary artery bypass surgery....

  16. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    OpenAIRE

    Jun, Min-Ho; Kim, Young-Min; Bae, Jang-Han; Jung, Chang Jin; Cho, Jung-Hee; Jeon, Young Ju

    2016-01-01

    The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the s...

  17. Evolution of shear stress, protein expression, and vessel area in an animal model of arterial dilatation in hemodialysis grafts

    Science.gov (United States)

    Misra, Sanjay; Fu, Alex A.; Misra, Khamal D.; Glockner, James F.; Mukhopadyay, Debabrata

    2010-01-01

    Purpose To evaluate the wall shear stress, protein expression of matrix metalloproteinases-2 (MMP-2), -9 (MMP-9), and the inhibitors (tissue inhibitor of matrix metalloproteinases-1 (TIMP-1), and -2 (TIMP-2)), and vessel area over time in a porcine model for hemodialysis polytetrafluoroethylene (PTFE) grafts. Materials and methods In 21 pigs, subtotal renal infarction was performed and 28 days later, a PTFE graft was placed to connect the carotid artery to the ipsilateral jugular vein. Phase contrast MR was used to measure blood flow and vessel area at 1, 3, 7, and 14 days after graft placement. Wall shear stress was estimated from Poiseuille’s law. Animals were sacrificed at day 3 (N=7), day 7 (N=7), and day 14 (N=7) and expression of MMP-2, MMP-9, TIMP-1, and TIMP-2 were determined at the grafted and control arteries. Results The mean wall shear stress of the grafted artery was higher than the control artery at all time points (P<0.05). It peaked by day 3 and decreased by days 7–14 as the vessel area nearly doubled. By days 7–14, there was a significant increase in active MMP-2 followed by a significant increase in pro and active MMP-9 by day 14 (P<0.05, grafted artery versus control). TIMP-1 expression peaked by day 7 and then decreased while TIMP-2 expression was decreased at days 7–14. Conclusions The wall shear stress of the grafted artery peaks by day 3 with increased MMP-2 activity by days 7–14 followed by pro and active MMP-9 by day 14 and the vessel area nearly doubled. PMID:20123196

  18. Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

    NARCIS (Netherlands)

    Piers, LH; Dorgelo, J; Tio, RA; Jessurun, GAJ; Oudkerk, M; Zijlstra, F

    This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic

  19. Radial artery approach for coronary intervention - early experience

    International Nuclear Information System (INIS)

    Jan, H.; Hadi, A.; Fahim, M.; Gul, A.M.; Irfan, M.; Khan, S.B.; Hafizullah, M.

    2012-01-01

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  20. Radial artery approach for coronary intervention - early experience

    Energy Technology Data Exchange (ETDEWEB)

    Jan, H; Hadi, A; Fahim, M; Gul, A M; Irfan, M; Khan, S B; Hafizullah, M [Lady Reading Hospital and Khyber Medical University, Peshawar (Pakistan). Dept. of Cardiology

    2012-01-15

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  1. Off-pump Coronary Artery Bypass Graft in a High Risk Patient ...

    African Journals Online (AJOL)

    On-pump coronary artery bypass graft (CABG) entails the use of cardiopulmonary bypass (CPB). The procedure is safe but it's not without complications like neurocognitive deficits, cerebrovascular accidents, myocardial ischemic injury and activation of inflammatory pathways that contribute to pulmonary, renal, hematologic ...

  2. Diagnosis of arterial prosthetic graft infection by 111In oxine white blood cell scans

    International Nuclear Information System (INIS)

    McKeown, P.P.; Miller, D.C.; Jamieson, S.W.; Mitchell, R.S.; Reitz, B.A.; Olcott, C.; Mehigan, J.T.; Silberstein, R.J.; McDougall, I.R.

    1982-01-01

    Early and accurate diagnosis of infected prosthetic arterial grafts is difficult, despite the application of diverse diagnostic modalities. Delay in making the diagnosis is largely responsible for the high amputation and mortality rates associated with this complication. In nine patients with suspected graft infections, 111 In white blood cell scanning was useful and accurate. Graft infection was proved in five cases and ruled out in three. One false-positive scan was due to a sigmoid diverticular abscess overlying the graft. 111 In white blood cell scans may improve the accuracy of diagnosing infected prosthetic grafts, which may result in better limb and patient salvage rates

  3. Factors associated with mortality in patients undergoing coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Cintia Koerich

    Full Text Available ABSTRACT Objective: to investigate the factors associated with mortality in patients undergoing coronary artery bypass grafting in a cardiovascular referral hospital in Santa Catarina. Method: quantitative, exploratory, descriptive and retrospective study. The medical records of 1447 patients, from 2005 to 2013, were analyzed for statistically related variables, these being: profile, hospitalization diagnosis, risk factors for coronary artery disease, complications recorded during the hospitalization, length of hospitalization and cause of death. Results: the mortality rate was 5.3% during the study period. Death was more common in females and those of black skin color, with a mean age of 65 years. Acute myocardial infarction was the most common hospitalization diagnosis. The majority of the complications recorded during hospitalization were characterized by changes in the cardiovascular system, with longer hospitalization periods being directly related to death from septic shock. Conclusion: the data provide subsidies for nursing work with preventive measures and early detection of complications associated with coronary artery bypass grafting. This reinforces the importance of using the data as quality indicators, aiming to guarantee care guided by reliable information to guide managers in planning patient care and high complexity health services.

  4. Human urotensin II in internal mammary and radial arteries of patients undergoing coronary surgery

    DEFF Research Database (Denmark)

    Chen, Zhi-Wu; Yang, Qin; Huang, Yu

    2009-01-01

    (max):20.4+/-4.8%, p7.1%). The relaxation was abolished by endothelium denudation...... and by indomethacin, oxadiazoloquinoxalinone or N(omega)-nitro-L-arginine, oxyhemoglobin, and Ca2+-activated K+ channel (K(Ca)) blockers. Urotensin receptor mRNA was detected in both arteries. CONCLUSIONS: hU-II is an important spasmogen in arterial grafts with receptors expressed in IMA and RA. hU-II elicits...

  5. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  6. Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access

    International Nuclear Information System (INIS)

    Geijer, Haakan; Persliden, Jan

    2004-01-01

    The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also responded to a questionnaire concerning discomfort and pain during and after the procedure. The mean DAP was 69.8 Gy cm 2 using femoral access and 70.5 Gy cm 2 using radial access. Separating the access site from confounding factors with a multiple regression, there was a 13% reduction in DAP when using radial access (p=0.038). Procedure times did not differ (p=0.81). Bed confinement was much longer in the femoral access group (448 vs 76 min, p=0.000). With femoral access, there was a significantly higher patient grading for chest (p=0.001) and back pain (p=0.003) during the procedure and for access site (p=0.000) and back pain (p=0.000) after the procedure. Thirty-two femoral access patients (28%) were given morphine-type analgesics in the post-procedure period compared to three radial access patients (5%, p=0.001). DAP does not increase when using radial instead of femoral access and the patients grade discomfort and pain much lower when using radial access. Radial access is thus beneficial to use. (orig.)

  7. Exercise through a cardiac rehabilitation program attenuates oxidative stress in patients submitted to coronary artery bypass grafting.

    Science.gov (United States)

    Taty Zau, José Francisco; Costa Zeferino, Rodrigo; Sandrine Mota, Nádia; Fernandes Martins, Gerez; Manoel Serra, Salvador; Bonates da Cunha, Therezil; Medeiros Lima, Daniel; Bragança Pereira, Basilio de; Matos do Nascimento, Emília; Filho, Danilo Wilhelm; Curi Pedrosa, Rozangela; Pedrosa, Roberto Coury

    2018-12-01

    Cardiovascular disease is the main cause of morbidity and mortality in the world and oxidative stress has been implicated in the pathogenesis. Cardiac rehabilitation in patients with coronary artery disease submitted to coronary artery bypass grafting may prevent cardiovascular events probably through the attenuation of oxidative stress. The aim of this study was to evaluate the benefits of a cardiac rehabilitation program in the control of the systemic oxidative stress. The studied population consisted of 40 patients, with chronic stable coronary artery disease submitted to coronary artery bypass grafting, who attended a cardiac rehabilitation program. Biomarkers of oxidative stress were evaluated in the blood of these patients at different moments. After the onset of cardiac rehabilitation, there was a significant and progressive decrease in thiobarbituric acid reactive substances levels and protein carbonyls, an initial increase and subsequent decrease in superoxide dismutase, catalase and glutathione peroxidase activities. Also, a progressive increase of uric acid, while ferric reducing antioxidant power levels increased only at the end of the cardiac rehabilitation and a tendency to increase of glutathione contents. The results suggest that regular exercise through a cardiac rehabilitation program can attenuate oxidative stress in chronic coronary artery disease patients submitted to coronary artery bypass grafting.

  8. Relationship between pre-extubation positive endexpiratory pressure and oxygenation after coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Reijane Oliveira Lima

    2015-08-01

    Full Text Available Abstract Introduction After removal of endotracheal tube and artificial ventilation, ventilatory support should be continued, offering oxygen supply to ensure an arterial oxygen saturation close to physiological. Objective: The aim of this study was to investigate the effects of positive-end expiratory pressure before extubation on the oxygenation indices of patients undergoing coronary artery bypass grafting. Methods: A randomized clinical trial with seventy-eight patients undergoing coronary artery bypass grafting divided into three groups and ventilated with different positive-end expiratory pressure levels prior to extubation: Group A, 5 cmH2O (n=32; Group B, 8 cmH2O (n=26; and Group C, 10 cmH2O (n=20. Oxygenation index data were obtained from arterial blood gas samples collected at 1, 3, and 6 h after extubation. Patients with chronic pulmonary disease and those who underwent off-pump, emergency, or combined surgeries were excluded. For statistical analysis, we used Shapiro-Wilk, G, Kruskal-Wallis, and analysis of variance tests and set the level of significance at P<0.05. Results Groups were homogenous with regard to demographic, clinical, and surgical variables. There were no statistically significant differences between groups in the first 6 h after extubation with regard to oxygenation indices and oxygen therapy utilization. Conclusion: In this sample of patients undergoing coronary artery bypass grafting, the use of different positive-end expiratory pressure levels before extubation did not affect gas exchange or oxygen therapy utilization in the first 6 h after endotracheal tube removal.

  9. The clinical research of off-pump coronary artery bypass grafting by small incision at the left chest.

    Science.gov (United States)

    Xiao, L-B; Zhang, Y-H; Zhou, J-W; Yang, M; Ling, Y-P; Gao, Z-S; Wang, Y-S

    2016-01-01

    To explore the clinical value of off-pump coronary artery bypass grafting by small incision at the left chest, and develop a better surgical regimen for coronary heart disease patients. 201 coronary heart disease patients who need coronary artery bypass grafting were required and randomly divided into 2 groups including a control group and an observation group. There were 107 cases in the control group who received coronary bypass grafting by extracorporeal circulation; there were 103 cases in the observation group who received off-pump coronary bypass grafting by small incision at the left chest. The duration of the mechanism ventilation, length of stay in ICU, hospitalization time, postoperative drainage volume, and the occurrence rate of complications were recorded and compared. The duration of mechanism ventilation, length of stay in ICU, hospitalization time and postoperative drainage volume in the control group were (19.21 ± 1.33) hours, (5.08 ± 0.57) days, (21.20 ± 2.34) days and (997.68 ± 96.35) mL, which were (7.73 ± 0.74) hours, (2.83 ± 0.16) days, (15.67 ± 1.18) days and (901.53 ± 89.32) mL in the observation group respectively, with statistical difference between the two groups (pdisease, pulmonary infection, perioperative cardiac infarction and mortality did not display a significant difference between the two groups (p > 0.05). Off-pump coronary artery bypass grafting by small incision at the left chest is a surgical method with less injury and fast recovery, which can be used as the preferred therapeutical method for the coronary heart disease patients who need coronary artery bypass grafting.

  10. Balloon-Expandable Stent Graft for Treating Uretero-Iliac Artery Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Guntau, Moritz, E-mail: guntau@med.uni-marburg.de [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hegele, Axel [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Rheinheimer, Stephan [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany); Hofmann, Rainer [Philipps University, Department of Urology and Pediatric Urology, Marburg University Hospital (Germany); Mahnken, Andreas H. [Philipps University, Department of Diagnostic and Interventional Radiology, Marburg University Hospital (Germany)

    2017-06-15

    PurposeTo evaluate the safety, efficacy and outcome of percutaneous balloon-expandable covered stent graft placement for uretero-iliac artery fistula (UAF) treatment.MethodsThis retrospective study evaluated the single-center experience of percutaneous balloon-expandable covered stent graft placement (ADVANTA™, Atrium Hudson, NH, USA) in UAF. Data were obtained from a prospective institutional database. Patient follow-up included complications, symptoms recurrence and mortality rate.ResultsTen UAFs in eight patients (3 males; 5 females) with a mean age of 64.5 (35–77) years were identified. All patients had a history pelvic malignancy, extirpative surgery (n = 6), long-term ureteral stenting (n = 7) and pelvic radiation (n = 5). All procedures were completed successfully without complications. Thirty-day mortality rate was zero. At a median follow-up of 6 (1–60) months, one patient suffered recurrent hematuria requiring a secondary stent graft placement 26 months after the initial treatment. During follow-up, five patients died of the underlying disease (43, 66, 105, and 183 and 274 days after the last procedure).ConclusionPercutaneous balloon-expandable stent graft placement in UAF is a safe and effective treatment option. Implantation of stent grafts should be considered as treatment of choice in UAF.

  11. [Revascularization surgery of an anuric solitary kidney using the left colic artery as a free graft].

    Science.gov (United States)

    da Gama, A Dinis; Nunes, J Silva; Cunha e Sá, Diogo; Pedro, Luís Mendes

    2003-01-01

    The thrombotic occlusion of one renal artery may become completely asymptomatic, due to the functionality of the contralateral kidney. However, in rare circumstances, such is the case of individuals with a solitary kidney, a situation of anuria and acute renal failure may constitute the main presentation of the condition. The authors report the clinical case of a 43 year old male patient, with the previous diagnosis of an infrarenal aortic occlusion and a single left kidney, who developed a thrombotic occlusion of the renal artery, with anuria and acute renal failure. The patient underwent an emergency revascularization procedure, consisting in the implantation of a prosthetic bypass graft from the superceliac aorta to the renal artery, with immediate recovery of the diuresis and renal function. Seventeen months later as a consequence of an anastomotic hyperplasia, an occlusion of the bypass graft occurred, again with anuria and acute renal failure. The patient was reoperated on and due to the inadequacy of both saphenous veins to be used as the material of choice for the revascularization procedure, a redundant segment of the left colic artery (Riolan's arcade) was removed and used as an interposition graft, from the middle colic artery to the renal artery, followed by an immediate restoration of diuresis and renal function. The singular and recurrent character of this clinical condition and the utilization of an original, eventually unique and well succeeded revascularization procedure, prompted its presentation and divulgation.

  12. Constitutive modeling of coronary artery bypass graft with incorporated torsion

    Czech Academy of Sciences Publication Activity Database

    Horný, L.; Chlup, Hynek; Žitný, R.; Adámek, T.

    2009-01-01

    Roč. 49, č. 2 (2009), s. 273-277 ISSN 0543-5846 R&D Projects: GA ČR(CZ) GA106/08/0557 Institutional research plan: CEZ:AV0Z20760514 Keywords : coronary artery bypass graft * constitutive model * digital image correlation Subject RIV: BJ - Thermodynamics Impact factor: 0.439, year: 2009 http://web.tuke.sk/sjf-kamam/mmams2009/contents.pdf

  13. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  14. A new beating-heart off-pump coronary artery bypass grafting training model

    NARCIS (Netherlands)

    Bouma, Wobbe; Kuijpers, Michiel; Bijleveld, Aanke; De Maat, Gijs E.; Koene, Bart M.; Erasmus, Michiel E.; Natour, Ehsan; Mariani, Massimo A.

    OBJECTIVES: Training models are essential in mastering the skills required for off-pump coronary artery bypass grafting (OPCAB). We describe a new, high-fidelity, effective and reproducible beating-heart OPCAB training model in human cadavers. METHODS: Human cadavers were embalmed according to the

  15. Non-invasive assessment of coronary artery bypass graft patency using 16-slice computed tomography angiography

    Directory of Open Access Journals (Sweden)

    Uren Neal G

    2007-06-01

    Full Text Available Abstract Background Invasive coronary angiography is the gold standard means of imaging bypass vessels and carries a small but potentially serious risk of local vascular complications, including myocardial infarction, stroke and death. We evaluated computed tomography as a non-invasive means of assessing graft patency. Methods Fifty patients with previous coronary artery bypass surgery who were listed for diagnostic coronary angiography underwent contrast enhanced computed tomography angiography using a 16-slice computed tomography scanner. Images were retrospectively gated to the electrocardiogram and two dimensional axial, multiplanar and three dimensional reconstructions acquired. Sensitivity, specificity, positive and negative predictive value, accuracy and level of agreement for detection of graft patency by multidetector computed tomography. Results A total of 116 grafts were suitable for analysis. The specificity of CT for the detection of graft patency was 100%, with a sensitivity of 92.8%, positive predictive value 100%, negative predictive value 85.8% and an accuracy of 94.8%. The kappa value of agreement between the two means of measuring graft patency was 0.9. Mean radiation dose was 9.0 ± 7.2 mSv for coronary angiography and 18.5 ± 4 mSv for computed tomography. Pooled analysis of eight studies, incorporating 932 grafts, confirmed a 97% accuracy for the detection of graft patency by multidetector computed tomography. Conclusion Computed tomography is an accurate, rapid and non-invasive method of assessing coronary artery bypass graft patency. However, this was achieved at the expense of an increase in radiation dose.

  16. Does a similar procedure result in similar survival for women and men undergoing isolated coronary artery bypass grafting?

    Science.gov (United States)

    Attia, Tamer; Koch, Colleen G; Houghtaling, Penny L; Blackstone, Eugene H; Sabik, Ellen Mayer; Sabik, Joseph F

    2017-03-01

    To (1) identify sex-related differences in risk factors and revascularization strategies for patients undergoing coronary artery bypass grafting (CABG), (2) assess whether these differences influenced early and late survival, and (3) determine whether clinical effectiveness of the same revascularization strategy was influenced by sex. From January 1972 to January 2011, 57,943 adults-11,009 (19%) women-underwent primary isolated CABG. Separate models for long-term mortality were developed for men and women, followed by assessing sex-related differences in strength of risk factors (interaction terms). Incomplete revascularization was more common in men than women (26% vs 22%, P  .9) with lower survival in both sexes. Single ITA grafting was associated with equally (P = .3) better survival in women and men. Although bilateral ITA grafting was associated with better survival than single ITA grafting, it was less effective in women-11% lower late mortality (hazard ratio, 0.89 [0.77-1.022]) versus 27% lower in men (hazard ratio, 0.73 [0.69-0.77]; P = .01). Women on average have longer life expectancies than men but not after CABG. Every attempt should be made to use arterial grafting and complete revascularization, but for unexplained reasons, sex-related differences in effectiveness of bilateral arterial grafting were identified. Copyright © 2016. Published by Elsevier Inc.

  17. Skeletonization of Left Internal Mammary Artery in Coronary Artery Bypass Grafting

    International Nuclear Information System (INIS)

    Chaudhri, M.S.; Shah, M.U.A.; Asghar, M.I.; Janjua, A.M.; Iqbal, A.; Siddiqi, R.

    2016-01-01

    Objective: To compare mean per-operative flow capacity between skeletonized and pedicled left internal mammary artery (LIMA) in patients undergoing coronary artery bypass grafting (CABG) surgery. Study Design: Randomized control trial. Place and Duration of Study: Department of Cardiac Surgery, Armed Forces Institute of Cardiology and National Institute of Heart Diseases (AFIC-NIHD), Rawalpindi, Pakistan from February to August, 2013. Methodology: Patients undergoing CABG for coronary artery disease, under 80 years, excluded by the exclusion criteria; and fulfilling the inclusion criteria were randomly assigned to two groups of 70 each. One group underwent skeletonized and the other underwent pedicled technique of LIMA harvesting. Free flow was checked just before anastamosis of each LIMA to the LAD, manually in blood flow in ml per minute during cardiopulmonary bypass by allowing it to bleed into a 100 ml container over 20 seconds. A specialized proforma was used to record the age, gender, weight, disease, type of IMA used, and free flow of the IMA. Data was analyzed using SPSS 18. Result: The mean age of the patients was 57.16 years in 40 patients, ranging from 36 to 75 years. Disease pattern analysis showed 5 percent, 10.7 percent and 84.3 percent single, double and triple vessel coronary artery disease, respectively. There was significantly higher free flow in the skeletonized group than the pedicled group (p=0.04). Conclusion: Skeletonized IMA had superior flow to pedicled IMA in addition to its traditional proven advantages, which justifies its further use as a conduit for myocardial revascularization. (author)

  18. Coronary artery bypass grafting on the beating heart using the Octopus method

    NARCIS (Netherlands)

    Thijssens, K. M.; Rodrigus, I. E.; Amsel, B. J.; de Hert, S. G.; Moulijn, A. C.

    2000-01-01

    STUDY OBJECTIVE: To study the usefulness and effectiveness of off-pump coronary bypass grafting with the Octopus heart stabilizing device. METHOD: The files of thirty-one patients undergoing coronary artery bypass with the aid of the Octopus heart stabilizing device between April 1996 and October

  19. Depression and Anxiety following Coronary Artery Bypass Graft: Current Indian Scenario

    Directory of Open Access Journals (Sweden)

    Suprakash Chaudhury

    2016-01-01

    Full Text Available Epidemiological studies have shown a high prevalence of coronary artery disease among the Indian Population. Due to increasing availability and affordability of tertiary care in many parts of India, carefully selected patients undergo coronary artery bypass surgery to improve cardiac function. However, the procedure is commonly associated with depression and anxiety which can adversely affect overall prognosis. The objective of this review is to highlight early identifiable symptoms of depression and anxiety following coronary artery bypass graft (CABG in Indian context so as to facilitate prompt intervention for better outcome. The current review was able to establish firm evidence in support of screening for depression and anxiety following CABG. Management of depression and anxiety following CABG is briefly reviewed.

  20. Coronary artery aneurysm after stent implantation: acute and long-term results after percutaneous treatment with a stent graft.

    Science.gov (United States)

    Rubartelli, Paolo; Terzi, Giacomo; Borgo, Lorenzo; Giachero, Corinna

    2002-03-01

    A patient with unstable angina was treated with elective Palmaz-Schatz stent implantation on a focal stenosis of the left circumflex artery. One year later, a large (13 mm in diameter) coronary artery aneurysm was diagnosed at angiography in the stented site. Intravascular ultrasound examination confirmed the presence of a true aneurysm located at the proximal end of the stent. The aneurysm was successfully treated with a Jostent Graft (Jomed Implantate) consisting of two slotted tube stainless steel stents supporting a polytetrafluoroethylene tube. The stent graft was implanted under intravascular ultrasound guidance. The 18-month angiographic follow-up showed good patency of the stent graft and complete exclusion of the aneurysm.

  1. Lack of tolerance of headache and radial artery diameter during a 7 hour intravenous infusion of nitroglycerin

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Tfelt-Hansen, P

    1993-01-01

    . The intensity of the headache was mild to medium (median headache score 3, range 1-7). The mean dilatation of the radial artery was 36%. The dilatation in each individual, was stable over time, both during NTG and placebo, and it did not change with the double infusion rate. The headache score in each......Nitroglycerin-(NTG)-induced headache and dilatation of the radial artery were followed in a double blind, randomized, placebo-controlled, cross-over study in 6 healthy volunteers. NTG 0.5 microgram.kg-1 x min-1 or saline were infused i.v. for 7 h, and subsequently the infusion rate was doubled...... individual was more fluctuant. No tolerance either to the NTG-induced headache or arterial dilatation was observed....

  2. Towards Spirituality After Coronary Artery bypass grafting: A Hermeneutic Phenomenological Study

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi

    2017-03-01

    Full Text Available Abstract Background and Objectives: Patients are oriented towards spirituality after coronary artery bypass grafting (CABG. The aim of this study was to explore the patients’ spiritual experiences after CABG. Methods: This qualitative study was conducted using hermeneutic phenomenology. 11 participants (7 males and 4 females were interviewed in Tehran Heart Center Hospital in 2013 using maximum variation along with purposive sampling methods. The interviews were recorded and then converted to texts word for word. The texts were analyzed using van Manen six-step method. Results: The main theme of the contents which were experienced by the participants was spirituality and its sub contents were: trust in God, Supplicating to the Prophet and Imams, and accepting the will of God. Conclusion: The findings showed that the participants who had undergone surgery on coronary artery bypass grafting had a rise in spirituality. They took advantage of spirituality to handle their problems. Using the research findings, members of the treatment team, especially nurses, can use this study to advance care planning and to train patients and their families better.

  3. Balloon Tamponade Treatment of a Stent-graft Related Rupture with a Splenic Artery Pseudoaneurysm: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, See Hyung; Kim, Young Hwan [Dongsan Medical Center, Keimyung University College of Medicine, Daegu (Korea, Republic of)

    2009-09-15

    An arterial rupture resulting from stent-graft placement of a splenic artery pseudoaneurysm is a life-threatening complication and immediate endovascular or surgical treatment is indicated. We report a case of a stentgraft related splenic artery rupture treated solely with a prolonged balloon catheter tamponade, which resulted in preservation of vessel patency

  4. Prognostic information in administrative co-morbidity data following coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Abildstrøm, Steen Zabell; Hvelplund, Anders; Rasmussen, Søren

    2010-01-01

    The aim of this study was to evaluate the prognostic information obtainable from administrative data with respect to 30-day mortality following coronary artery bypass grafting (CABG) and to compare it with the European System for Cardiac Operative Risk Evaluation (EuroSCORE) recorded in a clinical...

  5. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  6. Improving coronary artery bypass grafting readmission outcomes from 2000 to 2012 in the Medicare population.

    Science.gov (United States)

    McNeely, Christian; Kwedar, Kathleen; Markwell, Stephen; Vassileva, Christina M

    2017-10-01

    The study objective was to examine trends in 30-day readmission after coronary artery bypass grafting in the Medicare population over 13 years. The study included isolated coronary artery bypass grafting procedures in the Medicare population from January 2000 to November 2012. Comorbidities and causes of readmission were determined using Internal Classification of Diseases, 9th Revision, Clinical Modification diagnostic codes. The cohort included 1,116,991 patients. Readmission rates decreased from 19.5% in 2000 to 16.6% in 2012 (P = .0001). There was significant improvement across all categories of admission status, age, race, gender, and hospital annual coronary artery bypass grafting volume that were analyzed. Adjusted odds of readmission in 2000 compared with 2012 was 1.28 (95% confidence interval, 1.24-1.32). Median length of stay for the readmission episode was 5 days, which improved to 4 days by 2012. Hospital mortality during the readmission episode was 2.8% overall and declined to 2.4% in 2012 (P = .0001). The most common primary readmission diagnoses were heart failure (12.6%), postoperative wound infection/nonhealing wound (8.9%), arrhythmias (6.4%), and pleural effusions (3.7%). Readmission for wound infections/nonhealing wounds decreased significantly over time, from 9.8% to 6.5% (P = .0001). In a large cohort of Medicare patients undergoing coronary artery bypass grafting over 13 years, there was a significant decrease in 30-day readmission rates, a reduction in readmission for wound infections, and reduced mortality during the readmission episode, despite an increase in patient comorbidities. The improvement in readmission rates was seen regardless of patient variables examined. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  7. Use of modified Sandwich-graft technique to preserve hypogastric artery in EVAR treatment of complex aortic aneurysm anatomy.

    Science.gov (United States)

    Mosquera Arochena, N; Rodríguez Feijoo, G; Carballo Fernandez, C; Molina Herrero, F; Fernandez Lebrato, R; Barrios Castro, A; Garcia Fernandez, I

    2011-10-01

    Since the introduction of the first endoprosthetic devices, continuous development in techniques and implants has occurred, such as the introduction of a stent graft with branches designed to preserve antegrade flow in the hypogastric artery, a stent-graft designed to treat extreme neck angulation and iliac tortuosity, as well as "Sandwich" and "Chimney" techniques used to maintain perfusion in branch vessels originating in the region to be treated. This paper describes how the Sandwich-Graft technique was adapted, as described by Lobato et al., employing the Aorfix™ system (Lombard Medical) and the Viabahn™ (W.L.Gore) to preserve hypogastric flow in cases with extreme neck angulation and iliac tortuosity. The study included four patients treated from April 2010 until November 2010 with the modified Sandwich technique. All patients eligible for this approach were considered unfit for open repair and were not suitable for an iliac branch graft (Z-BIS Zenith™ Cook Medical). A bifurcated endograft was implanted with specific, in-situ, branching to the target hypogastric artery and achieved clinical and technical success, in all the patients. After a 11-month follow-up in two cases and a six-month follow-up in the other two, clinical results were successful. All patients were endoleak-free, had patent hypogastric branches and had shrinking or stable aneurysms. The initial experience shows that the Sandwich technique with the Aorfix™ stent-graft demonstrated to be effective in endovascular repair of abdominal aortic aneurysms in patients with aortoiliac anatomy hostile to preserving hypogastric artery patency. This graft allows a broader group of patients to be treated with endovascular repair without potential complications of hypogastric artery occlusion; however, further studies are needed to evaluate long-term results in larger numbers of patients.

  8. Erectile dysfunction and pcsychoemotional state in ischemic heart disease patients undergone coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Ye. V. Pomeshkin

    2012-01-01

    Full Text Available The impact of erectile dysfunction on psychoemotional state of patients undergone coronary artery bypass graft surgery was evaluated. The International Index of Erectile Function, postcompression cavernous artery dilation test, nocturnal penile tumescence recording and psychophysiological exam were used. It was found that ischemic heart disease patients have higher incidence of associated psychoemotional and erectile dysfunctions.

  9. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  10. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  11. Comparison of the feasibility and effectiveness of transradial coronary angiography via right versus left radial artery approaches (from the PREVAIL Study).

    Science.gov (United States)

    Pelliccia, Francesco; Trani, Carlo; Biondi-Zoccai, Giuseppe G L; Nazzaro, Marco; Berni, Andrea; Patti, Giuseppe; Patrizi, Roberto; Pironi, Bruno; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio; Pristipino, Christian

    2012-09-15

    It remains undefined if transradial coronary angiography from a right or left radial arterial approach differs in real-world practice. To address this issue, we performed a subanalysis of the PREVAIL study. The PREVAIL study was a prospective, multicenter, observational survey of unselected consecutive patients undergoing invasive cardiovascular procedures over a 1-month observation period, specifically aimed at assessing the outcomes of radial approach in the contemporary real world. The choice of arterial approach was left to the discretion of the operator. Prespecified end points of this subanalysis were procedural characteristics. Of 1,052 patients consecutively enrolled, 509 patients underwent transradial catheterization, 304 with a right radial and 205 with a left radial approach. Procedural success rates were similar between the 2 groups. Compared to the left radial group, the right radial group had longer procedure duration (46 ± 29 vs 33 ± 24 minutes, p <0.0001) and fluoroscopy time (765 ± 787 vs 533 ± 502, p <0.0001). At multivariate analysis, including a parsimonious propensity score for the choice of left radial approach, duration of procedure (beta coefficient 11.38, p <0.001) and total dose-area product (beta coefficient 11.38, p <0.001) were independently associated with the choice of the left radial artery approach. The operator's proficiency in right/left radial approach did not influence study results. In conclusion, right and left radial approaches are feasible and effective to perform percutaneous procedures. In the contemporary real world, however, the left radial route is associated with shorter procedures and lower radiologic exposure than the right radial approach, independently of an operator's proficiency. Copyright © 2012 Elsevier Inc. All rights reserved.

  12. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    Energy Technology Data Exchange (ETDEWEB)

    Mehta, Vimal, E-mail: drvimalmehta@yahoo.co.in; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay [G.B. Pant Institute of Postgraduate Medical Education and Research (India)

    2016-01-15

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory.

  13. Massive Bleeding from Guidewire Perforation of an External Iliac Artery: Treatment with Hand-made Stent-Graft Placement

    International Nuclear Information System (INIS)

    Mehta, Vimal; Pandit, Bhagya Narayan; Mehra, Pratishtha; Nigam, Arima; Vyas, Aniruddha; Yusuf, Jamal; Mukhopadhyay, Saibal; Trehan, Vijay

    2016-01-01

    We report life-threatening bleeding from an external iliac artery perforation following guidewire manipulation in a patient with atherosclerotic iliac artery disease. This complication was successfully managed by indigenous hand-made stent-graft made from two peripheral stents in the catheterization laboratory

  14. In vivo quantitation of platelet deposition on human peripheral arterial bypass grafts using indium-111-labeled platelets. Effect of dipyridamole and aspirin

    International Nuclear Information System (INIS)

    Pumphrey, C.W.; Chesebro, J.H.; Dewanjee, M.K.; Wahner, H.W.; Hollier, L.H.; Pairolero, P.C.; Fuster, V.

    1983-01-01

    Indium-111-labeled autologous platelets, injected 48 hours after operation, were used to evaluate the thrombogenicity of prosthetic material and the effect of platelet inhibitor therapy in vivo. Dacron double-velour (Microvel) aortofemoral artery bifurcation grafts were placed in 16 patients and unilateral polytetrafluoroethylene femoropopliteal grafts were placed in 10 patients. Half the patients in each group received platelet inhibitors before operation (dipyridamole, 100 mg 4 times a day) and after operation (dipyridamole, 75 mg, and acetylsalicylic acid, 325 mg 3 times a day); the rest of the patients served as control subjects. Five-minute scintigrams of the graft region were taken with a gamma camera interfaced with a computer 48, 72, and 96 hours after injection of the labeled platelets. Platelet deposition was estimated from the radioactivities of the grafts and expressed as counts per 100 pixels per microcurie injected. Dipyridamole and aspirin therapy significantly reduced the number of platelets deposited on Dacron grafts and prevented platelet accumulation over 3 days. With the small amount of platelet deposition on polytetrafluoroethylene femoropopliteal artery grafts even in control patients, platelet inhibitor therapy had no demonstrable effect on platelet deposition on these grafts. It is concluded that (1) platelet deposition on vascular grafts in vivo can be quantitated by noninvasive methods, and (2) dipyridamole and aspirin therapy reduced platelet deposition on Dacron aortofemoral artery grafts

  15. Late Complication after Superficial Femoral Artery (SFA) Aneurysm: Stent-graft Expulsion Outside the Skin

    Energy Technology Data Exchange (ETDEWEB)

    Pecoraro, Felice, E-mail: felicepecoraro@libero.it; Sabatino, Ermanno R.; Dinoto, Ettore; Rosa, Giuliana La; Corte, Giuseppe; Bajardi, Guido [University of Palermo, Vascular Surgery Unit (Italy)

    2015-10-15

    A 78-year-old man presented with a 7-cm aneurysm in the left superficial femoral artery, which was considered unfit and anatomically unsuitable for conventional open surgery for multiple comorbidities. The patient was treated with stent-graft [Viabhan stent-graft (WL Gore and Associates, Flagstaff, AZ)]. Two years from stent-graft implantation, the patient presented a purulent secretion and a spontaneous external expulsion through a fistulous channel. No claudication symptoms or hemorrhagic signs were present. The pus and device cultures were positive for Staphylococcus aureus sensitive to piperacillin/tazobactam. Patient management consisted of fistula drainage, systemic antibiotic therapy, and daily wound dressing. At 1-month follow-up, the wound was closed. To our knowledge, this is the first case of this type of stent-graft complication presenting with external expulsion.

  16. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  17. Impact on early and late mortality after blood transfusion in coronary artery bypass graft surgery.

    Science.gov (United States)

    Santos, Antonio Alceu dos; Sousa, Alexandre Gonçalves; Thomé, Hugo Oliveira de Souza; Machado, Roberta Longo; Piotto, Raquel Ferrari

    2013-03-01

    To assess the 30-day and 1-year mortality associated to the red blood cell transfusion after coronary artery bypass grafting surgery. This procedure has been questioned by the international medical community, but it is still widely used in cardiac surgery. Therefore, it is needed more evidence of this medical practice in our country. We retrospectively analyzed 3,004 patients who underwent coronary artery bypass grafting surgery between June 2009 and July 2010. Patients were divided into two groups: non-transfused and transfused. The transfused group totaled 1,888 (63%) and non-transfused 1,116 (37%). There were 129 deaths in 30 days, with 108 (84%) in the transfused group and 21 (16%) in the non-transfused (Pconservation strategies should be encouraged to reduce blood products transfusions.

  18. Dialysis grafts arterial plug: Retrieval using the tulip sheath device in vitro

    International Nuclear Information System (INIS)

    Sharafuddin, Melhem J.; Titus, Jack L.; Gu Xiaoping; Hunter, David W.; Amplatz, Kurt

    1997-01-01

    The 'arterial plug' is a resistant thrombus that frequently persists at the arterial anastomosis of clotted hemodialysis grafts following thrombolytic therapy. We studied the physical and morphological characteristics of the plug and determined the feasibility of transcatheter removal in vitro using the tulip compression thrombectomy system. Sixteen thrombus plugs were recovered during surgical thrombectomy of clotted human dialysis grafts. The physical and gross physical characteristics of all plugs were analyzed. Eight specimens were evaluated microscopically. Transcatheter compression thrombectomy of eight plugs was attempted in vitro. Each plug was embedded in a polyvinyl tube filled with newly clotted blood and connected to a flow circuit. First, balloon-assisted aspiration thrombectomy (BAT) of soft thrombus was performed, while sparing the distal-most segment containing the plug. The tulip sheath was then introduced facing the 'arterial end' of the tube. The thrombus segment containing the plug was pulled back into the tulip mesh using either a 3 Fr Fogarty balloon catheter or a self-expanding rake. The tulip was closed to compress and remove the trapped plug. Near-complete thrombectomy of soft clot was achieved in all tested tubes. Compression and retrieval of the entire arterial plug was successful in all except one, where only partial compression of the plug occurred, presumably due to fibrotic changes. No fragmentation or embolization occurred in the remaining procedures. Spongy consistency was noted in 94% of the specimens. Microscopic evaluation showed organized layered thrombus with compaction in five plugs. Transcatheter removal of a thrombus plug is feasible in vitro using the tulip compression-thrombectomy system

  19. Coronary artery bypass grafting hemodynamics and anastomosis design: a biomedical engineering review.

    Science.gov (United States)

    Ghista, Dhanjoo N; Kabinejadian, Foad

    2013-12-13

    In this paper, coronary arterial bypass grafting hemodynamics and anastomosis designs are reviewed. The paper specifically addresses the biomechanical factors for enhancement of the patency of coronary artery bypass grafts (CABGs). Stenosis of distal anastomosis, caused by thrombosis and intimal hyperplasia (IH), is the major cause of failure of CABGs. Strong correlations have been established between the hemodynamics and vessel wall biomechanical factors and the initiation and development of IH and thrombus formation. Accordingly, several investigations have been conducted and numerous anastomotic geometries and devices have been designed to better regulate the blood flow fields and distribution of hemodynamic parameters and biomechanical factors at the distal anastomosis, in order to enhance the patency of CABGs. Enhancement of longevity and patency rate of CABGs can eliminate the need for re-operation and can significantly lower morbidity, and thereby reduces medical costs for patients suffering from coronary stenosis. This invited review focuses on various endeavors made thus far to design a patency-enhancing optimized anastomotic configuration for the distal junction of CABGs.

  20. Prognostic information in administrative co-morbidity data following coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Abildstrøm, Steen Zabell; Hvelplund, Anders; Rasmussen, Søren

    2010-01-01

    Objectives: The aim of this study was to evaluate the prognostic information obtainable from administrative data with respect to 30-day mortality following coronary artery bypass grafting (CABG) and to compare it with the European System for Cardiac Operative Risk Evaluation (EuroSCORE) recorded ...... was equal to that of the EuroSCORE (c-statistic 0.79). Conclusions: A standard co-morbidity index based on administrative data as well as on clinical data has proven equally useful for prediction of mortality amongst CABG patients.......Objectives: The aim of this study was to evaluate the prognostic information obtainable from administrative data with respect to 30-day mortality following coronary artery bypass grafting (CABG) and to compare it with the European System for Cardiac Operative Risk Evaluation (EuroSCORE) recorded...... in a clinical database. Methods: We used a co-morbidity index calculated from administrative data in the Danish National Patient Register by means of all admissions 1 year prior to CABG. In addition, each CABG was categorised as being isolated or not, and acute or not. The prognostic power of the co...

  1. Comparison of a priori versus provisional heparin therapy on radial artery occlusion after transradial coronary angiography and patent hemostasis (from the PHARAOH Study).

    Science.gov (United States)

    Pancholy, Samir B; Bertrand, Olivier F; Patel, Tejas

    2012-07-15

    Systemic anticoagulation decreases the risk of radial artery occlusion (RAO) after transradial catheterization and standard occlusive hemostasis. We compared the efficacy and safety of provisional heparin use only when the technique of patent hemostasis was not achievable to standard a priori heparin administration after radial sheath introduction. Patients referred for coronary angiography were randomized in 2 groups. In the a priori group, 200 patients received intravenous heparin (50 IU/kg) immediately after sheath insertion. In the provisional group, 200 patients did not receive heparin during the procedure. After sheath removal, hemostasis was obtained using a TR band (Terumo corporation, Tokyo, Japan) with a plethysmography-guided patent hemostasis technique. In the provisional group, no heparin was given if radial artery patency could be obtained and maintained. If radial patency was not achieved, a bolus of heparin (50 IU/kg) was given. Radial artery patency was evaluated at 24 hours (early RAO) and 30 days after the procedure (late RAO) by plethysmography. Patent hemostasis was obtained in 67% in the a priori group and 74% in the provisional group (p = 0.10). Incidence of RAO remained similar in the 2 groups at the early (7.5% vs 7.0%, p = 0.84) and late (4.5% vs 5.0%, p = 0.83) evaluations. Women, patients with diabetes, patients having not received heparin, and patients without radial artery patency during hemostasis had more RAO. By multivariate analysis, patent radial artery during hemostasis (odds ratio [OR] 0.03, 95% confidence interval [CI] 0.004 to 0.28, p = 0.002) and diabetes (OR 11, 95% CI 3 to 38,p patent hemostasis is maintained. Copyright © 2012 Elsevier Inc. All rights reserved.

  2. Coronary artery bypass grafting-related bleeding complications in patients treated with dual antiplatelet treatment

    NARCIS (Netherlands)

    Tomšič, Anton; Schotborgh, Mark A.; Manshanden, Johan S. J.; Li, Wilson W. L.; de Mol, Bas A. J. M.

    2016-01-01

    To evaluate the relationship between the timing of either ticagrelor or clopidogrel discontinuation and bleeding-related complications in patients undergoing isolated on-pump coronary artery bypass grafting (CABG). Between January 2012 and December 2014, 705 consecutive patients underwent isolated

  3. Coronary artery bypass grafting-related bleeding complications in patients treated with dual antiplatelet treatment.

    NARCIS (Netherlands)

    Tomsic, A.; Schotborgh, M.A.; Manshanden, J.S.; Li, W.W.L.; Mol, B.A. de

    2016-01-01

    OBJECTIVES: To evaluate the relationship between the timing of either ticagrelor or clopidogrel discontinuation and bleeding-related complications in patients undergoing isolated on-pump coronary artery bypass grafting (CABG). METHODS: Between January 2012 and December 2014, 705 consecutive patients

  4. Is there an indication for computed tomography and magnetic resonance imaging in the evaluation of coronary artery bypass grafts?

    NARCIS (Netherlands)

    Dikkers, R.; van der Zaag-Loonen HJ, [No Value; Willems, T.P.; Post, W.J.; Oudkerk, M.

    2009-01-01

    This meta-analysis evaluates the diagnostic accuracy of multidetector computed tomography (MDCT) and magnetic resonance imaging (MRI) for bypass graft occlusion and stenosis detection compared with coronary angiography in post-coronary artery bypass graft patients. The indication for noninvasive

  5. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    2018-01-01

    Full Text Available Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min. Resumo: Objetivo: Diversos relatos alegam que a pressão arterial (PA na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do

  6. Decline in Health-Related Quality of Life 6 Months After Coronary Artery Bypass Graft Surgery

    DEFF Research Database (Denmark)

    El Baz, Noha; Pedersen, Susanne S.; van Dijk, Jitse P

    2013-01-01

    Although coronary artery bypass graft (CABG) is known to improve health-related quality of life (HRQoL), this improvement does not seem to be realized in all patients who had undergone CABG surgery....

  7. Effects of low dose aspirin (50 mg/day), low dose aspirin plus dipyridamole, and oral anticoagulant agents after internal mammary artery bypass grafting: patency and clinical outcome at 1 year. CABADAS Research Group of the Interuniversity Cardiology Institute of The Netherlands. Prevention of Coronary Artery Bypass Graft Occlusion by Aspirin, Dipyridamole and Acenocoumarol/Phenprocoumon Study

    NARCIS (Netherlands)

    van der Meer, J.; Brutel de la Rivière, A.; van Gilst, W. H.; Hillege, H. L.; Pfisterer, M.; Kootstra, G. J.; Dunselman, P. H.; Mulder, B. J.; Lie, K. I.

    1994-01-01

    This study was performed to compare the efficacy and safety of aspirin, aspirin plus dipyridamole, and oral anticoagulant agents in the prevention of internal mammary artery graft occlusion. Antithrombotic drugs increase vein graft patency after coronary artery bypass surgery. Their benefit after

  8. Effects of various factors on Doppler ultrasonographic measurements of radial and coccygeal arterial blood pressure in privately owned, conscious cats.

    Science.gov (United States)

    Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I

    2017-04-01

    OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.

  9. Evaluation of anatomy and variations of superficial palmar arch and upper extremity arteries with CT angiography.

    Science.gov (United States)

    Kaplanoglu, Hatice; Beton, Osman

    2017-04-01

    To evaluate the abnormalities and variations of the arterial system of upper extremities and superficial palmar arch with computed tomography angiography and to guide the clinician during this procedure. A total of 156 upper extremities of 78 cases were retrospectively analyzed using computed tomography angiography. The study was approved by the local ethics committee of the hospital. From the analysis of the computed tomography angiography images, the following information was recorded; the diameters and abnormalities of radial, ulnar and brachial arteries in both upper extremities, the presence of atherosclerotic changes or stenosis in these arteries, whether the superficial palmar arch was complete or incomplete, and arterial dominance. Also, the computed tomography angiography classification of superficial palmar arch distribution and anatomic configuration was performed. The mean baseline diameters of the radial, ulnar and brachial arteries of the cases were; 2.8 ± 0.6, 2.5 ± 0.7, and 4.7 ± 0.6 mm, respectively. A complete superficial palmar arch was observed in 69.2 % of the right hands and 70.5 % of the left hands. For the superficial palmar arches on the right side, the radial artery was dominant in two and the ulnar artery was dominant in 47 with the remaining showing codominance. On the left side, the radial artery was dominant in one hand, with the ulnar artery being dominant in 49 cases, and in 28 cases, there was codominance. In the superficial palmar arch classification, four of the arches (A-D) were defined as complete and the remaining three (E-G) as incomplete. The current study clarified different variations in palmar circulation and forearm arteries to aid the surgeon during trans-radial or trans-ulnar catheterization, hemodialysis, or coronary artery bypass grafting.

  10. Pulmonary hemodynamics and gas exchange in off pump coronary artery bypass grafting.

    Science.gov (United States)

    Vedin, Jenny; Jensen, Ulf; Ericsson, Anders; Samuelsson, Sten; Vaage, Jarle

    2005-10-01

    To investigate the influence of cardiopulmonary bypass on pulmonary hemodynamics and gas exchange. Low risk patients admitted for elective coronary artery bypass grafting were randomized to either on (n=25) or off pump (n=25) surgery. Central hemodynamics, gas exchange, and venous admixture were studied during and up to 20 h after surgery. There was no difference in pulmonary vascular resistance index (P=0.16), right ventricular stroke work index (P>0.2), mean pulmonary artery pressure (P>0.2) or pulmonary capillary wedge pressure (P>0.2) between groups. Soon after surgery there was a tendency towards higher cardiac index (P=0.07) in the off pump group. Arterial oxygen tension (P>0.2), hematocrit (P>0.2), venous admixture (P>0.2), and arterial-venous oxygen content difference (P=0.12) did not differ between groups. This prospective, randomized study showed no difference in pulmonary hemodynamics, pulmonary gas exchange, and venous admixture, in low risk patients undergoing off pump compared to on pump coronary artery bypass surgery.

  11. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  12. Coronary Artery Bypass Graft Surgery Cost Coverage by the Brazilian Unified Health System (SUS

    Directory of Open Access Journals (Sweden)

    Gilmara Silveira da Silva

    Full Text Available Abstract Introduction: Cost management has been identified as an essential tool for the general control and evaluation of health organizations. Objectives: To identify the coverage percentage of transferred funds from the Unified Health System for coronary artery bypass grafts in a philanthropic hospital having a consolidated costing system in the municipality of São Paulo. Methods: A quantitative, descriptive and cross-sectional research with information provided from a database composed of 1913 patients undergoing coronary artery bypass graft from March 13 to September 30, 2012, including isolated elective coronary artery bypass graft with the use of extracorporeal circulation. It excluded 551 (28.8% patients, among them 76 (4.0% deaths and 8 hospitalized patients, since the cost was compared according to the length of hospital stay. Therefore, the sample consisted of 1362 patients. Results: The average total cost per patient was $7,992.55. The average fund transfer by the Unified Health System was $3,450.73 (48.66%, resulting in a deficit of $4,541.82 (51.34%. Conclusion: The Unified Health System transfers covered 48.66% of the average total cost of hospitalization. Although the amount transferred increased with increasing costs, it was not proportional to the total cost, resulting in a percentage difference in revenue that was increasingly negative for each increase in cost and hospital stay. Those hospitalized for longer than seven days presented higher costs, older age, higher percentage of diabetics and chronic kidney disease patients and more postoperative complications.

  13. Thrombosed aneurysm of saphenous vein coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Rodolfo Mendes; Nastri Filho, Rogerio; Ferez, Marcus Antonio; Costa, Mauro Jose Brandao da; Laguna, Claudio Benedini; Valentin, Marcus Vinicius Nascimento, E-mail: rod_queiroz@hotmail.com [Documenta - Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Centro de Terapia Intensiva

    2017-06-15

    We describe the case of a male patient, aged 76 years, referred for cardiac investigation due to retrosternal chest pain and dyspnea. He had a history of acute myocardial infarction and angioplasties in the last 30 years, including a saphenous vein coronary artery bypass grafting (SVCABG). Echocardiogram showed hypoechoic oval formation near the right ventricle, suggesting a pericardial cyst. Computed angiotomography revealed a predominantly fusiform and thrombosed aneurysmal dilation of the SVCABG to the right coronary artery. SVCABG aneurysms are very rare and potentially fatal. They usually appear in the late postoperative period, and patients are often asymptomatic. On radiography, it is frequently presented as enlargement of the mediastinum, with echocardiography, computed tomography and magnetic resonance imaging being very useful for diagnosis. Coronary angiography is the gold standard to detect these cases. Our report illustrates a rare situation arising late from a relatively common surgery. Due to its severity, proper recognition in the routine assessment of patients with a similar history is essential. (author)

  14. Return to the workforce following coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Butt, Jawad H; Rørth, Rasmus; Kragholm, Kristian

    2018-01-01

    Background Returning to the workforce after coronary artery bypass grafting (CABG) holds important socioeconomic consequences not only for patients, but the society as well. Yet data on this issue are limited. We examined return to the workforce and associated factors in patients of working age.......0%) patients had returned to the workforce, 614 (10.2%) were on paid sick leave, 267 (4.4%) received disability pension, 250 (4.1%) were on early retirement, 57 (0.9%) had died, and 16 (0.3%) had emigrated. Factors associated with return to the workforce were identified using multivariable logistic regression...

  15. Endovascular Tubular Stent-Graft Placement for Isolated Iliac Artery Aneurysms

    International Nuclear Information System (INIS)

    Okada, Takuya; Yamaguchi, Masato; Kitagawa, Atsushi; Kawasaki, Ryota; Nomura, Yoshikatsu; Okita, Yutaka; Sugimura, Kazuro; Sugimoto, Koji

    2012-01-01

    Purpose: To evaluate the safety, efficacy, and mid-term outcomes of endovascular tubular stent-graft placement for repair of isolated iliac artery aneurysms (IAAs). Materials and Methods: Between January 2002 and March 2010, 20 patients (7 women and 13 men; mean age 74 years) underwent endovascular repair of 22 isolated IAAs. Two patients underwent endovascular repair for bilateral aneurysms. Ten para-anastomotic aneurysms (45%) developed after open abdominal aortic aneurysm (AAA) repair with an aorto-iliac graft, and 12 were true aneurysms (55%). Eleven straight and 11 tapered stent-grafts were placed. Contrast-enhanced computed tomography (CT) was performed to detect complications and evaluate aneurysmal shrinkage at week 1, 3, 6, and 12 months and once every year thereafter. Non–contrast-enhanced CT was performed in seven patients with chronic kidney disease. Results: All procedures were successful, without serious complications, during the mean (range) follow-up period of 746 days (47–2651). Type II endoleak not requiring treatment was noted in one patient. The mean (SD) diameters of the true and para-anastomotic aneurysms significantly (p < 0.05) decreased from 42.0 (9.3) to 36.9 (13.6) mm and from 40.1 (13.0) to 33.6 (15.8) mm, respectively; the mean (SD) shrinkage rates were 15.1% (20.2%) and 18.9% (22.4%), respectively. The primary patency rate was 100%, and no secondary interventions were required. Four patients (21%) developed transient buttock claudication, and one patient (5%) developed colorectal ischaemia, which was treated conservatively. Conclusion: Endovascular tubular stent-graft placement for the repair of isolated IAAs is safe and efficacious. Tapered stent-grafts of various sizes are required for accurate placement.

  16. The Lived Experiences of Patients Waiting for Coronary Artery Bypass Grafting: A Hermeneutic Phenomenological Study

    Directory of Open Access Journals (Sweden)

    Mohammad Abbasi

    2017-06-01

    Full Text Available Background and Objectives: Waiting for coronary artery bypass grafting is an unpleasant experience for patients and is associated with physical and psychological problems. The aim of this study was to recognize lived experiences of patients waiting for coronary artery bypass graft. Methods: This qualitative study was conducted using an interpretative phenomenological approach and proposed method of Van Manen. Twelve participants (9 men and 3 women were purposefully selected with maximum variation from Shahid Beheshti Hospital of Qom city, in 2016. The data of this study were collected through in-depth semi-structured interviews in the period of time between 40 to 70 minutes. The recorded interviews were transcribed verbatim to text, then, the transcribed texts were analyzed using the proposed van Manen’s six-step method. Results: From analysis of participants' statements, concepts, such as sense of panic, fear of death, understanding patients’ collaboration, understanding the importance of heart, decision for heart surgery, and trying to keep calm, were deduced. Conclusion: The participants of this study, from diagnosis of cardiovascular disease until the time of artery bypass grafting, thought that they were at risk for heart attack and death, and in spite of fear of death and sense of panic, they used peer-patients to control these negative experiences. Therefore, the members of health care team, particularly nurses, can provide necessary trainings to help patients from diagnosis time until surgery.

  17. Investigating the Effect of Swedish massage on Thoracic Pain in Patients Undergoing Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Zahra Pishkarmofrad

    2016-05-01

    Full Text Available Pain is one of the common complications after coronary artery bypass graft surgery. The current study aimed to investigate the effect of Swedish massage on thoracic pain in patients undergoing coronary artery bypass graft surgery at Ali-ibn Abi Talib Hospital of Zahedan, Iran in 2015. This study was performed on 50 patients undergoing coronary artery bypass graft surgery at Ali-ibn Abi Talib Hospital of Zahedan in 2015 in a randomized controlled clinical trial method. The patients were randomly divided into two massage and control groups with 25 cases in each group. The intervention group received Swedish massage for 20 minutes on the first day of transferring to cardiac surgical ward; however, the control group went under the routine control of the ward. Patients’ pain intensity were measured and recorded 15 minutes before and after the intervention using Visual Analog Scale (VAS. Statistical analysis was done using Chi-square test, independent t-test and paired t-test and SPSS Software version 21. There was no statistical significant difference between the two groups in terms of pain intensity before the intervention. The mean pain score before and after intervention was 60.80±11.46 and 44.32±11.58 in the massage group and 58.64±14.42 and 58.60±14.40 in th e control group, respectively. The result of covariance test showed that the mean pain score after intervention was significantly lower in the massage group than the control group (P=0.0001. Considering the effect of Swedish massage on reducing pain in patients undergoing coronary artery bypass graft, massage therapy can be used as a safe and low-cost non-drug method for reducing pain in these patients.

  18. Patients undergoing PCI from the femoral route by default radial operators are at high risk of vascular access-site complications.

    Science.gov (United States)

    Rafie, Ihsan M; Uddin, Muez M; Ossei-Gerning, Nicholas; Anderson, Richard A; Kinnaird, Timothy D

    2014-02-01

    Radial artery (RA) access for PCI has a lower incidence of vascular access-site (VAS) complications than the femoral artery (FA) approach. However, even for default radial operators certain patients are intervened upon from the FA. We examined the demographics and incidence of VAS complications when default radial operators resort to the FA for PCI. The demographics and VAS complications were compared by access site retrospectively for all PCI cases performed by default radial operators (n=1,392). A modified ACUITY trial definition of major VAS complication was used. FA puncture occurred in 25.2% (351/1,392) of cases. Patients were more likely to be female, older and weigh less than patients undergoing PCI from the RA. The FA procedure was likely to be more complex with larger sheaths, more left main stem, graft and multivessel intervention, and there was a greater proportion of emergency cases. Despite increased case complexity, glycoprotein inhibitors were used less frequently in femoral cases (26.5% vs. 36.8%, prisk factors for access-site bleeding are disproportionately high in the population requiring FA puncture by default radial operators, and as a result such patients have a high rate of vascular access-site complications.

  19. Risk factors for prolonged hospital stay after isolated coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Elayne Kelen de Oliveira

    2013-09-01

    Full Text Available INTRODUCTION: Characteristics of the patient and the coronary artery bypass grafting may predispose individuals to prolonged hospitalization, increasing costs and morbidity and mortality. OBJECTIVE: The objective of this study was to evaluate individual and perioperative risk factors of prolonged hospitalization in intensive care units and wards. METHODS: We conducted a case-control study of 104 patients undergoing isolated coronary artery bypass grafting with cardiopulmonary bypass. Patients hospitalized >3 days in the intensive care unit or >7 days in the ward were considered for the study. The association between variables was estimated by the chi-square test, odds ratio and logistic regression; P 3 days in the intensive care unit occurred for 22.1% of patients and >7 days in the ward for 27.9%. Among preoperative factors, diabetes (OR=3.17 and smoking (OR=4.07 were predictors of prolonged intensive care unit stay. Combining the pre-, intra-and postoperative variables, only mechanical ventilation for more than 24 hours (OR=6.10 was predictive of intensive care unit outcome. For the ward outcome, the preoperative predictor was left ventricular ejection fraction 24 hours for the intensive care unit and presence of infection for the ward.

  20. Early Introduction of Everolimus Immunosuppressive Regimen in Liver Transplantation with Extra-Anatomic Aortoiliac-Hepatic Arterial Graft Anastomosis

    Directory of Open Access Journals (Sweden)

    Emanuele Felli

    2014-01-01

    Full Text Available Liver transplantation is the treatment of choice for patients with acute and chronic end-stage liver disease, when no other medical treatment is possible. Despite high rates of 1- to 5-year survival, long-term adverse effects of immunosuppressant agents remain of major concern. Current research and clinical efforts are made to develop immunosuppressant agents that minimize adverse effects along with a low rate of graft rejection. Tailoring immunosuppressive therapy to individual patients by the use of proliferation signal inhibitors seems to be the best way to minimize toxicity and increase efficacy. Recently everolimus has been introduced in clinical practice; among its adverse effects an increased incidence of arterial graft thrombosis in renal transplants, vascular anastomosis leakage, impaired wound healing, and thrombotic microangiopathy have been reported. We present the case of a 54-year-old patient submitted to liver transplantation for end-stage liver disease treated by an extra-anatomic aortoiliac-hepatic arterial graft anastomosis and early postoperative introduction of everolimus for acute renal failure. Postoperative period was characterized by two abdominal collections and reactivation of cytomegalovirus infection that were treated by percutaneous drainage and antiviral therapy, respectively; the patient is well after 8-month followup with patency of the arterial conduit and no leakage.

  1. Multidetector CT angiography as a noninvasive tool to assess graft patency of surgically reconstructed diffusely diseased coronary arteries

    Directory of Open Access Journals (Sweden)

    Ahmed I. Rezk

    2014-03-01

    Conclusion: Extensive reconstruction of the diffusely diseased LAD using an ITA graft could be performed safely with very encouraging results. MDCT angiography is an excellent non invasive tool not only to evaluate graft patency in the reconstructed LAD but also to detect other findings in asymptomatic patients with diffuse coronary artery disease for better and more close follow up.

  2. Transluminal recanalization of chronic total occlusion of radial artery using rendezvous technique: a case report and literature review.

    Science.gov (United States)

    Arabi, Mohammad; Ahmed, Ishtiaq; Qattan, Nabeel

    2014-01-01

    Although endovascular management of lower extremity peripheral arterial disease (PAD) is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO) using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  3. Various clinical scenarios leading to development of the string sign of the internal thoracic artery after coronary bypass surgery: the role of competitive flow, a case series

    Directory of Open Access Journals (Sweden)

    Kolozsvari Rudolf

    2012-01-01

    Full Text Available Abstract Background The left internal mammary artery (LIMA is the choice for grafting of the left anterior descending coronary artery (LAD. One possible mechanism of the rare graft failure involve the presence of competitive flow. Method 105 patients who had undergone coronary bypass grafting between 1998 and 2000 were included in this observational study. The recatheterizations were performed 28 months after the operations. The rate of patency the LIMA grafts was determined, and the cases with graft failure were analyzed. Results The LIMA graft was patent in 99 patients (94%. Six patients (6% exhibited diffuse involution of the graft (string sign. The string sign was always associated with competitive flow as the basis of the LIMA graft involution. In one case quantitative re-evaluation of the preoperative coronary angiography revealed merely less than 50% diameter stenosis on the LAD with a nonligated side-branch of the LIMA. At recatheterization in two patients the pressure wire measurements demonstrated only a non-significant decrease of the fractional flow reserve (0.83 and 0.89, despite the 53% and 57% diameter stenosis in the angiogram. Another patient displayeda significant regression of the LAD lesion between the pre- and postoperative coronary angiography (from 76% to 44% as the cause of the development of the competitive flow. In one instance, a radial artery graft on the LAD during a redo bypass operation resulted in competitive flow in the radial graft due to the greater diameter than that of the LIMA. In a further patient, competitive flow developed from a short sequential part of the LIMA graft between the nonsignificantly stenosed diagonal branch and the LAD, with involution of the main part of the graft to the diagonal branch. Conclusions The most common cause of the development of the string sign of a LIMA graft due to competitive flow is overassessment of the lesion of the LAD. Regression of a previous lesion or some other

  4. Hypothenar hammer syndrome: long-term follow-up after ulnar artery reconstruction with the lateral circumflex femoral artery.

    Science.gov (United States)

    de Niet, A; Van Uchelen, J H

    2017-06-01

    In symptomatic patients with hypothenar hammer syndrome, the occluded part of the ulnar artery can be reconstructed with an autologous graft. Venous grafts are used frequently, but they are known for their low patency rate. Arterial grafts show better patency rates than venous grafts in coronary bypass surgery. We performed 11 ulnar artery reconstructions with the descending branch of the lateral circumflex femoral artery and compared these with previously performed venous reconstructions. All patients with an arterial graft reconstruction had a patent graft at a mean follow-up of 63 months. In addition, nine out of 11 patients reported improvement in their symptoms. The patency rate of venous reconstructions in hypothenar hammer syndrome is significantly lower. Arterial grafting for hypothenar hammer syndrome has superior patency compared with venous grafting; we recommend it as the surgical treatment of choice for symptomatic hypothenar hammer syndrome. 4.

  5. Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

    International Nuclear Information System (INIS)

    Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques

    2009-01-01

    Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

  6. Accidental Coverage of Both Renal Arteries during Infrarenal Aortic Stent-Graft Implantation: Cause and Treatment

    Directory of Open Access Journals (Sweden)

    Umberto Marcello Bracale

    2014-01-01

    Full Text Available The purpose of this paper is to report a salvage maneuver for accidental coverage of both renal arteries during endovascular aneurysm repair (EVAR of an infrarenal abdominal aortic aneurysm (AAA. A 72-year-old female with a 6 cm infrarenal abdominal aortic aneurysm was treated by endovascular means with a standard bifurcated graft. Upon completing an angiogram, both renal arteries were found to be accidentally occluded. Through a left percutaneous brachial approach, the right renal artery was catheterized and a chimney stent was deployed; however this was not possible for the left renal artery. A retroperitoneal surgical approach was therefore carried out with a retrograde chimney stent implanted to restore blood flow. After three months, both renal arteries were patent and renal function was not different from the baseline. Both endovascular with percutaneous access via the brachial artery and open retroperitoneal approaches with retrograde catheterization are feasible rescue techniques to recanalize the accidentally occluded renal arteries during EVAR.

  7. Transluminal Recanalization of Chronic Total Occlusion of Radial Artery Using Rendezvous Technique: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohammad Arabi

    2014-01-01

    Full Text Available Although endovascular management of lower extremity peripheral arterial disease (PAD is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  8. Percutaneous coronary angioplasty versus coronary artery bypass grafting in treatment of unprotected left main stenosis (NOBLE)

    DEFF Research Database (Denmark)

    Mäkikallio, Timo; Holm, Niels R; Lindsay, Mitchell

    2016-01-01

    Background Coronary artery bypass grafting (CABG) is the standard treatment for revascularisation in patients with left main coronary artery disease, but use of percutaneous coronary intervention (PCI) for this indication is increasing. We aimed to compare PCI and CABG for treatment of left main...... coronary artery disease. Methods In this prospective, randomised, open-label, non-inferiority trial, patients with left main coronary artery disease were enrolled in 36 centres in northern Europe and randomised 1: 1 to treatment with PCI or CABG. Eligible patients had stable angina pectoris, unstable......, and 5% versus 2% (2 . 25, 0 . 93-5 . 48, p= 0 . 073) for stroke. Interpretation The findings of this study suggest that CABG might be better than PCI for treatment of left main stem coronary artery disease....

  9. Nonselective carotid artery ultrasound screening in patients undergoing coronary artery bypass grafting: Is it necessary?

    Science.gov (United States)

    Masabni, Khalil; Sabik, Joseph F.; Raza, Sajjad; Carnes, Theresa; Koduri, Hemantha; Idrees, Jay J.; Beach, Jocelyn; Riaz, Haris; Shishehbor, Mehdi H.; Gornik, Heather L.; Blackstone, Eugene H.

    2016-01-01

    Objectives To determine whether nonselective preoperative carotid artery ultrasound screening alters management of patients scheduled for coronary artery bypass grafting (CABG), and whether such screening affects neurologic outcomes. Methods From March 2011 to September 2013, preoperative carotid artery ultrasound screening was performed on 1236 of 1382 patients (89%) scheduled to undergo CABG. Carotid artery stenosis (CAS) was classified as none or mild (any type 0%–59% stenosis), moderate (unilateral 60%-79% stenosis), or severe (bilateral 60%-79% stenosis or unilateral 80%–100% stenosis). Results A total of 1069 (86%) hadartery evaluation altered the management of a minority of patients undergoing CABG; this did not translate into perioperative stroke risk. Hence, a more targeted approach for preoperative carotid artery evaluation should be adopted. PMID:26586360

  10. Effect of various antithrombotic regimens (aspirin, aspirin plus dipyridamole, anticoagulants) on the functional status of patients and grafts one year after coronary artery bypass grafting

    NARCIS (Netherlands)

    Mulder, B. J.; van der Doef, R. M.; van der Wall, E. E.; Tijssen, J. G.; Piek, J. J.; van der Meer, J.; Dunning, A. J.

    1994-01-01

    From 1987 until 1991 a large prospective randomized multicentre study was performed in The Netherlands, Germany and Switzerland entitled CABADAS (Prevention of Coronary Artery Bypass graft occlusion by Aspirin, Dipyridamole, and Acenocoumarol/Phenprocoumon Study). The aim of CABADAS was to evaluate

  11. IMPACT OF PREOPERATIVE METOPROLOL ON THE OCCURRENCE OF NEW-ONSET ATRIAL FIBRILLATION AFTER CORONARY ARTERY BYPASS GRAFTING

    Directory of Open Access Journals (Sweden)

    Salla Surya Prakasarao

    2016-09-01

    Full Text Available BACKGROUND Postoperative Atrial fibrillation (POAF is the most frequent arrhythmia observed after Coronary artery bypass grafting (CABG. Worldwide incidence is documented to be 20-30% in patients undergoing isolated Coronary artery bypass grafting (CABG. There is no published data for Indian population so far. Hence, the objective of our study is to analyse the occurrence of newonset POAF in our Indian population and to assess whether the preoperative beta-blocker therapy has any role in its prevention. MATERIAL AND METHODS This is a retrospective and prospective observational study of coronary artery disease patients in Andhra Medical College, Visakhapatnam, who underwent coronary artery bypass grafting at various institutions between August 2013 and August 2014. The patients with documented AF during the preoperative period and patients undergoing associated cardiac procedures have been excluded from the study. Data has been collected from the patients’ medical records and the relative clinical variables were analysed. Chi-square test used for statistical analysis. RESULTS 227 patients with coronary artery disease (followed up at our centre were found to have undergone CABG during the study period. Among the 227 patients, 191 (84.14% were males and 36 (15.85% were females. The mean age of patients developing AF was 61.9±8.7 and for patients in sinus rhythm was 58.7±7.9 years (range: 37-80 years. 159 patients received preoperative Metoprolol and 68 patients were free from Metoprolol usage. The overall incidence of AF was 6.16%. 3.1% of patients with Metoprolol were noted to have AF while 13.23% of patients with no Metoprolol coverage developed new-onset AF (p<0.05. 14.28% of patients developing AF were with LV function <40%. The mean duration of ICU stay for patients who had POAF was 73.74±39.33 hours and 34.47±19.39 hours for patients in sinus rhythm. CONCLUSION The incidence of Postoperative Atrial fibrillation in Indian patients is

  12. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain : Impact on respiratory muscle function, activity, mood and exercise capacity

    OpenAIRE

    會田, 信子; 渋谷, 優子; 吉野, 克樹; Komoda, Masaji; 井上, 智子

    2002-01-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) g...

  13. Femoro-Supragenicular Popliteal Bypass with a Bridging Stent Graft in a Diffusely Diseased Distal Target Popliteal Artery: Alternative to Below-Knee Popliteal Polytetrafluoroethylene Bypass

    Directory of Open Access Journals (Sweden)

    Joung Hun Byun

    2017-10-01

    Full Text Available Background: Lesions in distal target arteries hinder surgical bypass procedures in patients with peripheral arterial occlusive disease. Methods: Between April 2012 and October 2015, 16 patients (18 limbs with lifestyle- limiting claudication (n=12 or chronic critical limb ischemia (n=6 underwent femoral–above-knee (AK polytetrafluoroethylene (PTFE bypass grafts with a bridging stent graft placement between the distal target popliteal artery and the PTFE graft. Ring-supported PTFE grafts were used in all patients with no available vein for graft material. Follow-up evaluations assessed clinical symptoms, the ankle-brachial index, ultrasonographic imaging and/or computed tomography angiography, the primary patency rate, and complications. Results: All procedures were successful. The mean follow-up was 12.6 months (range, 11 to 14 months, and there were no major complications. The median baseline ankle-brachial index of 0.4 (range, 0.2 to 0.55 significantly increased to 0.8 (range, 0.5 to 1.0 at 12 months (p<0.01. The primary patency rate at 12 months was 83.3%. The presenting symptoms resolved within 2 weeks. Conclusion: In AK bypasses with a diffusely diseased distal target popliteal artery or when below-knee (BK bypass surgery is impossible, this procedure could be clinically effective and safe when used as an alternative to femoral-BK bypass surgery.

  14. Antibiotic prophylaxis and risk of Clostridium difficile infection after coronary artery bypass graft surgery.

    Science.gov (United States)

    Poeran, Jashvant; Mazumdar, Madhu; Rasul, Rehana; Meyer, Joanne; Sacks, Henry S; Koll, Brian S; Wallach, Frances R; Moskowitz, Alan; Gelijns, Annetine C

    2016-02-01

    Antibiotic use, particularly type and duration, is a crucial modifiable risk factor for Clostridium difficile. Cardiac surgery is of particular interest because prophylactic antibiotics are recommended for 48 hours or less (vs ≤24 hours for noncardiac surgery), with increasing vancomycin use. We aimed to study associations between antibiotic prophylaxis (duration/vancomycin use) and C difficile among patients undergoing coronary artery bypass grafting. We extracted data on coronary artery bypass grafting procedures from the national Premier Perspective claims database (2006-2013, n = 154,200, 233 hospitals). Multilevel multivariable logistic regressions measured associations between (1) duration (difficile as outcome. Overall C difficile prevalence was 0.21% (n = 329). Most patients (59.7%) received a cephalosporin only; in 33.1% vancomycin was added, whereas 7.2% received vancomycin only. Extended prophylaxis was used in 20.9%. In adjusted analyses, extended prophylaxis (vs standard) was associated with significantly increased C difficile risk (odds ratio, 1.43; confidence interval, 1.07-1.92), whereas no significant associations existed for vancomycin use as adjuvant or primary prophylactic compared with the use of cephalosporins (odds ratio, 1.21; confidence interval, 0.92-1.60, and odds ratio, 1.39; confidence interval, 0.94-2.05, respectively). Substantial inter-hospital variation exists in the percentage of extended antibiotic prophylaxis (interquartile range, 2.5-35.7), use of adjuvant vancomycin (interquartile range, 4.2-61.1), and vancomycin alone (interquartile range, 2.3-10.4). Although extended use of antibiotic prophylaxis was associated with increased C difficile risk after coronary artery bypass grafting, vancomycin use was not. The observed hospital variation in antibiotic prophylaxis practices suggests great potential for efforts aimed at standardizing practices that subsequently could reduce C difficile risk. Copyright © 2016 The

  15. Percutaneous Stent-Graft Repair of a Mycotic Pulmonary Artery Pseudoaneurysm

    International Nuclear Information System (INIS)

    Chou Meichun; Liang Hueilung; Pan Huayban; Yang Chienfang

    2006-01-01

    Ruptured mycotic pulmonary pseudoaneurysm is a lethal complication. Emergent surgical repair is usually recommended, but still associated with a high mortality rate. We present a patient in whom mycotic pulmonary pseudoaneurysm was a complication after surgical lobectomy 2 weeks earlier. This patient had suffered from repeated massive hemoptysis. After emergent surgical repair of the ruptured pulmonary artery stump, another episode of massive hemorrhage occurred. The pulmonary arteriogram revealed a segmental stenosis and a large, wide-necked, lobulated pseudoaneurysm at the left proximal pulmonary artery. We deployed a balloon-expandable stent-graft (48 mm in length mounted on a 12 mm x 40 mm angioplasty balloon) across the stenotic segment and the neck of the pulmonary pseudoaneurysm. Hemostasis was achieved immediately and, under a 4-week antibiotic treatment, patient was transferred to a local hospital for medical care. This case report demonstrates the benefit of minimally invasive endovascular therapy in a critically ill patient. A literature review of the etiology and management of mycotic pulmonary pseudoaneurysm is included

  16. The Effect of Inhalation Aromatherapy on Physiological and Psychological Parameters of Patient’s Candidate for Coronary Artery Bypass Graft: Pilot Study

    Directory of Open Access Journals (Sweden)

    N. Rajai

    2016-08-01

    Full Text Available Introduction: Anxiety and stress are common problems before coronary artery bypass graft surgery has a destructive effect on the patient's condition. One of the medications therapies that are effective in reducing anxiety level is Aromatherapy. The aim of this study is to assess the effect of inhalation aromatherapy on physiological and psychological parameters of patients who are candidate for coronary artery bypass graft. Method: In this pilot study, 30 patients candidate of coronary artery bypass graft were selected by convenient sampling method. For intervention on the morning of the surgery, patients inhaled Lavender essential oil from a distance of 5 cm of the nose, for 20 minutes. Physiological and psychological parameters of patients the day before surgery and then 5 and 30 minutes after intervention was estimated by Form vital signs and DASS questionnaire. Data were analyzed in three phases using Descriptive Statistics and repeated measures ANOVA by SPSS.17. Results: 20% of patients were female, 80% male with an average age of 65/36±8/05. The results show a significant difference between the three time phases in variable of the pulse (P = 0/041, respiration (P = 0/040 and stress (P=0.046. Discussion: Aromatherapy can be an effective way to reduce stress levels and pulse in patients candidate for coronary artery bypass graft. Since this results study obtained from a pilot study, to Generalize the results, clinical trials with larger sample size is recommended.

  17. Coronary artery bypass grafting without cardiopulmonary bypass and without interruption of native coronary flow using a novel anastomosis site restraining device ("Octopus").

    Science.gov (United States)

    Borst, C; Jansen, E W; Tulleken, C A; Gründeman, P F; Mansvelt Beck, H J; van Dongen, J W; Hodde, K C; Bredée, J J

    1996-05-01

    This study assessed the feasibility of coronary artery bypass grafting on the beating heart without interruption of native coronary blood flow using a novel anastomosis site restraining device. Recently, an end-to-side bypass technique was described that does not require interruption of flow in the recipient artery. By means of a suction device ("Octopus"), in 31 pigs the epicardium was grasped and immobilized through an arm contraption fixed to the operating table. In the first 15 consecutive pigs (study I), the two-dimensional motion of an epicardial beacon was monitored. In 16 subsequent pigs (study II), an internal mammary artery was grafted under the microscope in two steps to a proximal coronary artery segment, without cardiopulmonary bypass. First, the internal mammary artery was sutured end-to-side to the outside of the coronary artery. Secondly, an orifice was punched in the partitioning coronary wall by an excimer laser catheter introduced through a temporary side-branch of the internal mammary artery. Study II: During 43 suction periods in four anastomosis areas, immobilization was achieved for 15 to 169 min (>30 h in total) in 13 open- and 9 closed-chest procedures without hemodynamic deterioration. The area circumscribed by the edges of the beacon trajectory (area in which the anastomosis is to be tracked) was reduced from 73.0 +/- 43.0 mm(2) (mean +/- SD) to 1.3 +/- 0.5 mm(2) (p<0.001) in the open-chest and to 0.2 +/- 0.2 mm(2) in the closed-chest procedure. At 6 weeks, no myocardial or coronary suction lesions were found. Study II: Nonocclusive anastomosis surgery required 25 +/- 3 min. No leakage, serious arrhythmias, graft closure or hemodynamic deterioration occurred during the procedure or for 2 h after ligating the coronary artery proximally. At 6 weeks, all seven grafts were patent. Coronary bypass on the beating heart without interruption of coronary flow is feasible. In both open- and in closed-chest procedures, the "Octopus" reduced

  18. Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Lee, Yi-Wei [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Guan, Yu-Xiang [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Law, Wei-Yip, E-mail: m002325@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Su, Chen-Tau, E-mail: m005531@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China)

    2013-12-11

    Objective: To determine the optimal image reconstruction windows in the assessment of coronary artery bypass grafts (CABGs) with 256-slice computed tomography (CT), and to assess their associated optimal pulsing windows for electrocardiogram-triggered tube current modulation (ETCM). Methods: We recruited 18 patients (three female; mean age 68.9 years) having mean heart rate (HR) of 66.3 beats per minute (bpm) and a heart rate variability of 1.3 bpm for this study. A total of 36 CABGs with 168 segments were evaluated, including 12 internal mammary artery (33.3%) and 24 saphenous vein grafts (66.7%). We reconstructed 20 data sets in 5%-step through 0–95% of the R–R interval. The image quality of CABGs was assessed by a 5-point scale (1=excellent to 5=non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Two reviewers discriminated optimal reconstruction intervals for each CABG segment in each temporal window. Optimal windows for ETCM were also evaluated. Results: The determined optimal systolic and diastolic reconstruction intervals could be divided into 2 groups with threshold HR=68. The determined best reconstruction intervals for low heart rate (HR<68) and high heart rate (HR>68) were 76.0±2.5% and 45.0±0% respectively. Average image quality scores were 1.7±0.6 with good inter-observer agreement (Kappa=0.79). Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001). The recommended windows of ETCM for low HR, high HR and all HR groups were 40–50%, 71–81% and 40–96% of R-R interval, respectively. The corresponding dose savings were about 60.8%, 58.7% and 22.7% in that order. Conclusions: We determined optimal reconstruction intervals and ETCM windows representing a good compromise between radiation and image quality for following bypass surgery using a 256-slice CT.

  19. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  20. Successful flow reduction surgery for a ruptured true posterior communicating artery aneurysm caused by the common carotid artery ligation for epistaxis.

    Science.gov (United States)

    Yamao, Yukihiro; Takahashi, Jun C; Satow, Tetsu; Iihara, Koji; Miyamoto, Susumu

    2014-01-01

    Carotid artery occlusion can lead to the development of rare true posterior communicating artery (PCoA) aneurysms because of hemodynamic stress on the PCoA. Surgical treatment of these lesions is challenging. The authors report a case of a true PCoA aneurysm that developed and ruptured 37 years after ligation of the ipsilateral common carotid artery for epistaxis. The lesion was successfully treated with clipping of the distal M1 segment of the middle cerebral artery (MCA) after the occipital artery-radial artery free graft-MCA bypass, which led to extreme reduction in collateral flow through the PCoA. A cortical branch, located just proximal to the obliteration site, functioned as a sufficient flow outlet. The aneurysm shrank, and the patient has been doing well without any symptoms for 5 years after surgery. M1 obliteration combined with high-flow extra-intracranial bypass might be a promising option for a true PCoA aneurysm, and therapeutic design that leaves a sufficient flow outlet on the M1 is mandatory to avoid unexpected occlusion of the M1 and its perforators.

  1. Endovascular stent graft for treatment of complicated spontaneous dissection of celiac artery: Report of two cases

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ung Rae; Lee, Young Hwan [Dept. of Diagnostic Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Hwan [Dept. of Diagnostic Radiology, Dongsan Medical Center, Keimyung University School of Medicine, Daegu (Korea, Republic of)

    2013-06-15

    We report 2 cases of complicated spontaneous dissection of the celiac artery, which were successfully treated by a stent graft. The first patient was a 47-year-old man who presented with acute abdominal pain. CT scan showed ruptured saccular aneurysm with surrounding retroperitoneal hematoma. The second patient was a 57-year-old man with progressive dissecting aneurysm. Endovascular stent graft was placed in the celiac trunk to control bleeding, and to prevent rupture in each patient. Follow-up CT scans showed complete obliteration of a dissecting aneurysm.

  2. Aneurisma sacular da artéria radial: a propósito de um caso clínico Sacular aneurysm of the radial artery: a case report

    Directory of Open Access Journals (Sweden)

    Nádia Duarte

    2011-06-01

    Full Text Available Os aneurismas da artéria radial são raros e esporádicos, sendo que os pseudoaneurismas são mais frequentes do que os aneurismas verdadeiros e maioritariamente de configuração sacular. A etiologia é variada e diferenciam-se de outros diagnósticos pela pulsação e frémito. Raramente se complicam de ruptura, sendo a trombose e embolização as principais complicações. Dos casos publicados sobre aneurismas verdadeiros da artéria radial, apenas um está descrito como sendo secundário a lesão ocupacional repetitiva, sendo a maioria de causa idiopática. Os autores descrevem um caso de uma mulher de 63 anos, referenciada à consulta de Cirurgia Vascular por crescimento de massa pulsátil na tabaqueira anatómica da mão esquerda. O estudo por eco-doppler e angiografia, confirmaram o diagnóstico de aneurisma sacular da artéria radial, com 20 mm de maior eixo, arcada palmar permeável e sem sinais de embolização distal. Foi submetida a aneurismectomia parcial com laqueação dupla proximal e distal e endoaneurismorrafia. A cirurgia e pós-operatório decorreram sem complicações, nomeadamente complicações isquémicas. A propósito desde caso clínico, discute-se a abordagem diagnóstica e opções terapêuticas.Radial artery aneurysms are sporadic and rare, pseudoaneurysms are more common than true aneurysms, mainly in saccular configuration. The etiology is varied and difference from other diagnostics is done by the presence of pulse and thrill. Thrombosis and embolization are the main complications, while rupture is rare. From the reported cases of true aneurysms of the radial artery, only one is described as being secondary to repetitive occupational injury, the majority being idiopathic. The authors describe the case of a 63 year old woman, referred to a Vascular Surgery consultation because of a growing pulsatile mass in the anatomical snuffbox of the left hand. The Doppler and Angiography studies confirmed the diagnosis of

  3. A new design concept for knitted external vein-graft support mesh.

    Science.gov (United States)

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights

  4. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    International Nuclear Information System (INIS)

    Fanelli, Fabrizio; Cannavale, Alessandro; Gazzetti, Marianna; Fantozzi, Cristiano; Taurino, Maurizio; Speziale, Francesco

    2013-01-01

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient’s clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  5. Spontaneous Rupture of Superficial Femoral Artery Repaired with Endovascular Stent-Grafting with use of Rendez-Vous Technique, Followed by Delayed Infection

    Energy Technology Data Exchange (ETDEWEB)

    Fanelli, Fabrizio, E-mail: fabrizio.fanelli@uniroma1.it; Cannavale, Alessandro [University of Rome ' Sapienza,' , Department of Radiological Sciences, Vascular and Interventional Radiology Unit (Italy); Gazzetti, Marianna [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy); Fantozzi, Cristiano; Taurino, Maurizio [University of Rome ' Sapienza,' , Department of Vascular Surgery (Italy); Speziale, Francesco [Sapienza University of Rome ' Sapienza,' , Department of Surgery Paride Stefanini, Vascular Surgery Division, Policlinico Umberto I (Italy)

    2013-02-15

    This is the case of a 72-year-old man with lower limb ischemia due to spontaneous rupture of nonaneurysmal superficial femoral artery that developed into thigh hematoma. After failure of a Fogarty revascularization, an emergency endovascular procedure was performed to restore the arterial continuity. A rendezvous procedure was performed with a double femoral and popliteal approach and two covered stent-grafts were deployed. Patient's clinical conditions immediately improved, but 4 months later the stent-grafts were surgically removed for infection and exteriorization. A femoropopliteal bypass was performed. After 1 year follow-up, the patient is in good clinical condition.

  6. Revascularização do miocárdio com enxerto livre de artéria radial: experiência inicial

    Directory of Open Access Journals (Sweden)

    Giorgio PIERACCIANI

    1997-07-01

    Full Text Available Foram estudados os resultados precoces do uso do enxerto livre de artéria radial (AR para a revascularização do miocárdio em 20 pacientes operados no período de maio a novembro de 1996. Pertenciam ao sexo masculino 16 (80% com média de idades de 57,1 anos (35 a 69. Foi utilizada a esternotomia mediana com o auxílio da circulação extracorpórea e a cardioplegia sangüínea intermitente em todos os casos. A AR foi retirada do membro superior não dominante e utilizada como parte aorto-coronária em 100% dos casos. Foi realizado um total de 64 enxertos, com média de 3,2 por pacientes (2 a 5. A AR foi anastomosada ao ramo diagonal 9 (45% vezes, ao ramo marginal esquerdo da artéria circunflexa 6 (30%, à coronária direita 4 (20% e ao ramo interventricular anterior 1 (5%. A artéria torácica interna esquerda (ATIE foi utilizada em 100% dos pacientes, a artéria torácica interna direita (ATID em 7 (35%, e a veia safena em 13 (65%. O diltiazen oral foi utilizado no período per-operatório para a prevenção do espasmo arterial. Não houve mortalidade hospitalar ou durante o seguimento de até 10 meses. Foi realizado estudo cineangiocoronáriográfico no período pós-operatório imediato em 17 (85% pacientes, que mostrou fluxo normal na AR em 16 (94,1%. Não houve seqüelas no membro superior do doador. Os resultados observados são semelhantes aos obtidos com a revascularização do miocárdio pelas técnicas usuais no Serviço, sem incremento na morbimortalidade precoce. A normalidade precoce do enxerto de artéria radial mostrou-se comparável ao da artéria torácica interna esquerda, coincidindo com os recentes relatos da técnica.Twenty patients underwent myocardial revascularization with a radial artery (RA between May and November 1996. The mean age was 57.1 years (35 to 69 and 16 patients (80% were male. Midsternotomy, extracorporeal circulation and antegrade blood cardioplegia were always used. A total of 64 grafts, 3.2 per

  7. Aorto-right atrial fistula secondary to rupture of an occluded old saphenous venous graft to right coronary artery.

    Science.gov (United States)

    Balestrini, Carlos Sebastian; Saaibi, José Federico; Ortiz, Santiago Navas

    2014-09-01

    We report a case of an acquired aorta-right atrial fistula, secondary to a ruptured proximal anastomosis of an old saphenous vein graft 12 years after a coronary artery bypass surgery, in a 57 year old patient with multiple cardiovascular risk factors. On admission, he presented with congestive heart failure and on examination a continuous murmur was detected on the right parasternal border. Catheterization showed a fistula from the proximal anastomosis of an occluded right coronary artery saphenous vein graft draining to the right atrium with a large left to right shunt. The fistula was successfully occluded by a percutaneous approach with a Life Tech duct occluder with complete resolution of heart failure. The patient was discharged one week afterwards. After a two-year follow-up, the fistula remained occluded. © 2013 Wiley Periodicals, Inc.

  8. Variations in the usage and composition of a radial cocktail during radial access coronary angiography procedures.

    LENUS (Irish Health Repository)

    Pate, G

    2011-10-01

    A survey was conducted of medication administered during radial artery cannulation for coronary angiography in 2009 in Ireland; responses were obtained for 15 of 20 centres, in 5 of which no radial access procedures were undertaken. All 10 (100%) centres which provided data used heparin and one or more anti-spasmodics; verapamil in 9 (90%), nitrate in 1 (10%), both in 2 (20%). There were significant variations in the doses used. Further work needs to be done to determine the optimum cocktail to prevent radial artery injury following coronary angiography.

  9. Early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome versus stable angina pectoris.

    Science.gov (United States)

    Fukui, Toshihiro; Tabata, Minoru; Morita, Satoshi; Takanashi, Shuichiro

    2013-06-01

    The aim of the present study was to determine the early and long-term outcomes of coronary artery bypass grafting in patients with acute coronary syndrome and stable angina pectoris. From September 2004 to September 2011, 382 patients with acute coronary syndrome (unstable angina pectoris and non-ST-segment elevation myocardial infarction) and 851 patients with stable angina pectoris underwent first-time isolated coronary artery bypass grafting at our institute. The early and long-term outcomes were compared between the 2 groups. Patients with acute coronary syndrome were older, were more likely to be women, had a smaller body surface area, and were more likely to have left main coronary artery disease. In both groups, bilateral internal thoracic artery grafts were used in approximately 89% of the patients, and off-pump techniques in approximately 97% of the patients. The acute coronary syndrome group had a greater operative death rate (2.6% vs 0.1%) and a greater incidence of low output syndrome (3.1% vs 1.2%) and hemodialysis requirement (2.9% vs 1.1%). Multivariate regression analysis demonstrated that age, acute coronary syndrome, lower ejection fraction, and higher creatinine level before surgery were independent predictors of operative death. However, among the hospital survivors, no differences were seen in freedom from all death (85.4% ± 2.5% vs 87.7% ± 2.0%), cardiac death (97.4% ± 0.9% vs 96.5% ± 0.9%), or major adverse cardiac and cerebrovascular events (78.0% ± 2.9% vs 78.1% ± 2.3%) at 7 years between the patients with acute coronary syndrome and stable angina pectoris. Although acute coronary syndrome is an independent predictor of early mortality in patients undergoing coronary artery bypass grafting, the long-term outcomes after surgery were similar between patients with acute coronary syndrome and stable angina pectoris who survived the early postoperative period. Copyright © 2013 The American Association for Thoracic Surgery. Published by

  10. Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: The ACRA-Spasm study

    NARCIS (Netherlands)

    Van Der Heijden, D.J. (Dirk J.); M.A.H. van Leeuwen (Maarten); G.N. Janssens (Gladys N.); Hermie, J. (Jailen); M.J. Lenzen (Mattie); M.J.P.F. Ritt; P.M. van de Ven (Peter); F. Kiemeneij (Ferdinand); N. van Royen (Niels)

    2016-01-01

    textabstractAims: The aim of this study was to analyse the relation between endothelial dysfunction (ED) and the occurrence of radial artery spasm (RAS) during transradial coronary procedures. Methods and results: From May 2014 to June 2015, endothelial function was assessed by EndoPAT and FMD

  11. Ulnar Artery Compression: A Feasible and Effective Approach to Prevent the Radial Artery Occlusion after Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Jun Tian

    2015-01-01

    Full Text Available Background: Radial artery (RA occlusion (RAO is not rare in patients undergoing coronary intervention by transradial approach (TRCI. Predictors of and prevention from RAO have not been systematically studied. This study aimed to analyze the risk factors of the weakness of RA pulsation (RAP and its predictive value for RAO after TRCI, and simultaneously to describe a feasible and effective approach to maintain RA patency. Methods: Between June 2006 and March 2010, all patients who underwent TRCI were classified according to the weakness of RAP after removing compression bandage with confirmation by Doppler ultrasound for the first 30 consecutive patients. Among a total of 2658 patients studied, 187 (7% patients having a weaker RAP were prospectively monitored. At 1 h after bandage removal, the ulnar artery in puncture side of all patients was blocked with manual compression to favor brachial and collateral artery blood flow through the RA until a good RAP was restored. The primary analysis was the occurrence of RAO. Results: Doppler ultrasound demonstrated the significant reduction of both systolic velocity (61.24 ± 3.95 cm/s vs. 72.31 ± 3.57 cm/s and diastolic velocity (1.83 ± 0.32 cm/s vs. 17.77 ± 3.97 cm/s in RA at access side as compared to the contralateral RA (all P < 0.001, but these velocities in ipsilateral ulnar artery (81.2 ± 2.16 cm/s and 13.1 ± 2.86 cm/s, respectively increased profoundly. The average time of ulnar artery compression was 4.1 ± 1.2 h (ranged 2.5-6.5 h. There were two patients experienced persistent RAO with a success rate of 98.9% and RAO in 0.075% of patients after ulnar artery compression was applied. The pulsation of the ulnar artery after compression was removed had not been influenced by the compression. Conclusions: After intervention using TRCI approach, the presence of a weaker RAP is an indicator of imminent RAO. The continuing compression of ipsilateral ulnar artery is an effective approach to

  12. Thoracic aortic stent-graft placement combined with left subclavian artery 'chimney operation': therapeutic analysis of 15 cases with insufficient proximal anchor area

    International Nuclear Information System (INIS)

    Liu Jiayi; Huang Lianjun; Fan Zhanming; Zhang Zhaoqi

    2012-01-01

    Objective: To discuss the strategies for the management of insufficient proximal anchoring area during the performance of transluminal stent-graft placement (TSGP), and to evaluate the feasibility of intentional coverage of the left subclavian artery (LSA) together with left subclavian artery stent-graft placement by using 'chimney operation' technique. Methods: A total of 15 patients with thoracic aortic diseases complicated by insufficient proximal anchoring area, who were encountered in authors' hospital during the period from Dec. 2009 to April 2011, were enrolled in this study. The clinical data were retrospectively analyzed. The thoracic aortic diseases included aortic dissection (n=6), aortic pseudoaneurysm (n=1), aortic aneurysm (n=4) and penetrating ulcer (n=4). Of the 15 patients, the distance between the lesion and LSA anchoring site 15 mm in 2. TSGP was carried out. The ostium of LSA was intentionally and completely covered by thoracic aortic stent-graft and left subclavian artery stent-graft placement was subsequently performed. The patients were kept under observation for symptoms of cerebral and upper limb ischemia. The postoperative complications such as endoleak and the patency of LSA were assessed with angiography. Results: Thoracic aortic stent-graft placement was successfully carried out in all 15 patients. In addition, one 'chimney' stent was properly implanted in LSA in each patient. After the procedure, no complications of nervous system or severe ischemia of upper extremity occurred. Follow-up examinations performed between 5 days to 3 months after the treatment revealed that the aortic stent-graft remained in stable condition and no type Ⅰ endoleak occurred, meanwhile the blood flow in 'chimney' stent was unobstructed. Conclusion: Intentional LSA coverage with 'chimney operation' can expand the applicability of TSGP with high tolerability. It is especially useful for patients with left vertebral artery blood supply dominance or with

  13. Should intentional endovascular stent-graft coverage of the left subclavian artery be preceded by prophylactic revascularisation?

    DEFF Research Database (Denmark)

    Weigang, Ernst; Parker, Jack A T C; Czerny, Martin

    2011-01-01

    subclavian artery (LSA) limiting the proximal landing zone site without proximal vessel coverage. In patients in whom the distance between the LSA and aortic lesion is too short, extension of the landing zone can be obtained by covering the LSA's origin with the endovascular stent graft (ESG). This manoeuvre...

  14. Effects of preoperative aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in patients undergoing off-pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Shim, Jae Kwang; Choi, Yong Seon; Oh, Young Jun; Bang, Sou Ouk; Yoo, Kyung Jong; Kwak, Young Lan

    2007-07-01

    Preoperative exposure to clopidogrel and aspirin significantly increases postoperative bleeding in patients undergoing on-pump coronary artery bypass graft surgery. Off-pump coronary bypass grafting has been proposed as an alternative technique to attenuate postoperative bleeding associated with clopidogrel. This study aimed to determine the effects of aspirin and clopidogrel therapy on perioperative blood loss and blood transfusion requirements in off-pump coronary artery bypass grafting. One hundred six patients scheduled for off-pump coronary artery bypass grafting were divided into three groups: aspirin and clopidogrel discontinued more than 6 days before surgery (group 1, n = 35), aspirin and clopidogrel continued until 3 to 5 days before surgery (group 2, n = 51), and both medications continued within 2 days of surgery (group 3, n = 20). Thromboelastographic tracings were analyzed before induction of anesthesia. Routine coagulation profiles were measured before and after surgery. A cell salvage device was used during surgery and salvaged blood was reinfused. Chest tube drainage and blood transfusion requirement were recorded postoperatively. Patient characteristics, operative data, and thromboelastographic tracings were similar among the groups. There were significant decreases in hematocrit level and platelet count and prolongation in prothrombin time postoperatively in all groups without any intergroup differences. The amounts of perioperative blood loss and blood transfusion required were all similar among the groups. Preoperative clopidogrel and aspirin exposure even within 2 days of surgery does not increase perioperative blood loss and blood transfusion requirements in patients undergoing elective off-pump coronary artery bypass grafting.

  15. Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis

    Directory of Open Access Journals (Sweden)

    Rolanas Dauksevicius

    2013-04-01

    Full Text Available Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner’s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.

  16. Graft patency after off-pump coronary artery bypass surgery is inferior even with identical heparinization protocols

    DEFF Research Database (Denmark)

    Houlind, Kim; Fenger-Grøn, Morten; Holme, Susanne J

    2014-01-01

    OBJECTIVE: To determine whether graft patency after on-pump and off-pump coronary artery bypass surgery is similar when performed using the same heparinization protocol. METHODS: In a randomized, controlled, multicenter trial, 900 patients more than 70 years of age received either on-pump or off......-pump coronary artery bypass surgery. Heparin was given to achieve an activated clotting time of 400 seconds before arteriotomy in both groups. After the procedure, protamine sulfate was given to revert the activated clotting time to less than 120 seconds. Coronary angiography was performed 6 months after...

  17. Closure of the Radial Forearm Free Flap Donor Site Using the Combined Local Triangular Full-Thickness Skin Graft.

    Science.gov (United States)

    Moreno-Sánchez, Manuel; González-García, Raúl; Ruiz-Laza, Luis; Manzano Solo de Zaldívar, Damián; Moreno-García, Carlos; Monje, Florencio

    2016-01-01

    Traditional donor-site closure has been associated with serious esthetic and functional morbidity. The purpose of this study was to assess morbidity in esthetics and function and measure the postoperative complications of the radial forearm free flap (RFFF) donor site after using combined local triangular full-thickness skin grafting. This prospective study of patients who underwent reconstruction of head and neck defects using an RFFF was conducted from July 2008 through December 2014. The donor site was repaired with a combined local triangular full-thickness skin graft. Quality of the scar, color match, tendon exposure, presence of necrosis, dehiscence of the suture, and presence of dysesthesia were recorded and analyzed using SPSS 21.0 software. One hundred consecutive patients (71 male and 29 female) underwent RFFF harvesting. RFFF donor-site defects ranged from 15 to 70 cm2; partial skin graft loss occurred in 7% of patients. Five patients (5%) had small dehiscences of the forearm skin graft, and 2 cases (2%) presented tendon exposure. In all cases, these sites healed secondarily by conservative management, with no final impairment of function. Esthetic results were considered excellent in 87%, good in 11%, and suboptimal in 2% of the cases. The combined local triangular full-thickness skin graft is a reliable method for closing RFFF donor-site defects because it obviates a second surgical site, it provides excellent color match and pliability, and it can be used for covering large defects of the donor site. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  18. CABG Versus PCI: Greater Benefit in Long-Term Outcomes With Multiple Arterial Bypass Grafting.

    Science.gov (United States)

    Habib, Robert H; Dimitrova, Kamellia R; Badour, Sanaa A; Yammine, Maroun B; El-Hage-Sleiman, Abdul-Karim M; Hoffman, Darryl M; Geller, Charles M; Schwann, Thomas A; Tranbaugh, Robert F

    2015-09-29

    Treatment of multivessel coronary artery disease with traditional single-arterial coronary artery bypass graft (SA-CABG) has been associated with superior intermediate-term survival and reintervention compared with percutaneous coronary intervention (PCI) using either bare-metal stents (BMS) or drug-eluting stents (DES). This study sought to investigate longer-term outcomes including the potential added advantage of multiarterial coronary artery bypass graft (MA-CABG). We studied 8,402 single-institution, primary revascularization, multivessel coronary artery disease patients: 2,207 BMS-PCI (age 66.6 ± 11.9 years); 2,381 DES-PCI (age 65.9 ± 11.7 years); 2,289 SA-CABG (age 69.3 ± 9.0 years); and 1,525 MA-CABG (age 58.3 ± 8.7 years). Patients with myocardial infarction within 24 h, shock, or left main stents were excluded. Kaplan-Meier analysis and Cox regression were used to separately compare 9-year all-cause mortality and unplanned reintervention for BMS-PCI and DES-PCI to respective propensity-matched SA-CABG and MA-CABG cohorts. BMS-PCI was associated with worse survival than SA-CABG, especially from 0 to 7 years (p = 0.015) and to a greater extent than MA-CABG was (9-year follow-up: 76.3% vs. 86.9%; p PCI hazard ratios (HR) were as follows: versus SA-CABG, HR: 0.87; and versus MA-CABG, HR: 0.38. DES-PCI showed similar survival to SA-CABG except for a modest 0 to 3 years surgery advantage (HR: 1.06; p = 0.615). Compared with MA-CABG, DES-PCI exhibited worse survival at 5 (86.3% vs. 95.6%) and 9 (82.8% vs. 89.8%) years (HR: 0.45; p PCI for all comparisons (all p PCI or DES-PCI, resulted in substantially enhanced death and reintervention-free survival. Accordingly, MA-CABG represents the optimal therapy for multivessel coronary artery disease and should be enthusiastically adopted by multidisciplinary heart teams as the best evidence-based therapy. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  19. [An experimental study of the healing of velour grafts].

    Science.gov (United States)

    Kobayashi, O

    1986-02-01

    An experimental study of implantation of velour grafts in the abdominal aorta or the external iliac artery of dogs was conducted with the object of evaluating the type of velour surface best fit for small-caliber artery implantation. Velour grafts measuring 4mm in diameter with differing velour surfaces were used as materials. Velour grafts now available on the market differ not only in velour surface but also in structure, notably in porosity and wall thickness. Hence each of the grafts used was reversed (i.e. inside out) and thus new grafts were prepared. These grafts were considered most suitable for making a comparative study of the effects of velour surface on healing. Macroscopic and histological findings revealed that each graft was good healing with the rate of patency as high as 84 percent. However, like Vasculour-D grafts, crimped grafts which preserve the crimp after implantation was significantly thicker at the internal valley than other grafts. Based on the findings of this experimental study non-crimped velour grafts were considered to be best fit for small-caliber artery implantation.

  20. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. The effectiveness of the program kinesitherapy men aged 45-65 years after coronary artery bypass graft (CABG.

    Directory of Open Access Journals (Sweden)

    Iermakov S.S.

    2011-01-01

    Full Text Available The purpose of research is the effectiveness of the training program in cardiac rehabilitation of 11 men at the age between 45 and 65 years undergoing coronary artery bypass grafting. The study used the reports of electrocardiographic exercise stress test, performed before and after training cycle each of the patient. In order to analyze the training loads were also used medical records, including diagnosis, prescribing doctor and ordered treatments. Training loads used in the training program in the rehabilitation of men undergoing coronary artery bypass graft allowed for effective implementation of the objectives pursued. The analysis of training loads and effectiveness of the rehabilitation program to the conclusion that the basis for the achievement of rehabilitation is to develop general fitness and aerobic endurance. Optimally balanced training loads, taking into account the individual needs of patients, is the key to success in the process of recovery after cardiac incident.

  2. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)-Results of the FERARI study.

    Science.gov (United States)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-12-01

    Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose-area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8min, p=0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p=0.826), procedural duration (46.0 vs. 45.0min, p=0.363) and contrast agent use (185.5 vs. 199.5ml, p=0.742) were also similar in radial and femoral PCI. There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Decellularized ovine arteries as small-diameter vascular grafts

    International Nuclear Information System (INIS)

    Mancuso, L; Cao, G; Gualerzi, A; Boschetti, F; Loy, F

    2014-01-01

    Atherosclerosis and its complications still represent the leading cause of death in the developed countries. While autologous blood vessels may be regarded as the best solution for peripheral and coronary bypass, they are unavailable in most patients. Even though tissue engineering techniques are often applied to the development of small-diameter vascular grafts, limiting factors of this approach are represented by the lack of essential extracellular matrix proteins and/or poor biomechanical properties of the scaffolds used. Along these lines, the aim of this study was to develop a decellularization protocol for ovine carotids to be used as suitable small-diameter vascular grafts. Samples were treated either with sodium dodecyl sulphate (SDS) or with Trypsin and Triton X-100; a final nuclease digestion was performed for both protocols. Morphological analyses demonstrate complete removal of nuclei and cellular components in treated vessels, also confirmed by significant reduction in wall thickness and DNA content. Essential extracellular matrix proteins such as collagen, elastin, and fibronectin are well preserved after decellularization. From a mechanical point of view, Trypsin and Triton X-100 treated arteries show elastic modules and compliance comparable to native carotids, whereas the use of SDS makes samples stiffer, with a significant decrease in the compliance mean value and an increase in longitudinal and circumferential Young’s modules. It is demonstrated that the treatment where Trypsin and Triton X-100 are combined guarantees complete decellularization of carotids, with no significant alteration of biomechanical and structural properties, thus preserving a suitable environment for adhesion, proliferation, and migration of cells. (paper)

  4. Brachial artery repair using the basilic vein as a reliable conduit in a 3-year-old child

    Directory of Open Access Journals (Sweden)

    Hyunyoung G. Kim

    2017-04-01

    Full Text Available A supracondylar fracture of the humerus is the most common upper extremity fracture in children with concurrent neurovascular complications. However, bypass grafting in the management of a pediatric open elbow dislocation with an arterial injury has rarely been reported in the literature. Hence, an adequate conduit for a vessel graft interposition remains questionable when a primary anastomosis is limited in an arterial reconstruction. The purpose of this study is to present a brachial artery reconstruction in a 3-year-old patient with an open supracondylar fracture of the humerus. In the clinical and surgical examination of the patient, an open wound in the left antecubital fossa presented with accompanying brachial artery injury. To repair the artery, a reverse end-to-end anastomosis was conducted using basilic vein graft from the ipsilateral arm under general anesthesia. The patient had palpable radial pulses in the postoperative clinical examination and was discharged without complications. The great saphenous vein (GSV has proven to be the most common and the best conduit for arterial reconstruction of the upper extremity in the adult patients. However, the GSV graft is known to have the propensity for becoming aneurysmal in pediatric patients. Some studies have demonstrated the basilic vein as a suitable conduit in pediatric patients, in that it has durable patency, fewer branches, size compatibility for anastomosis, and proximity to the brachial artery. Our case confirms the safety of using this autogenous vein from within the zone of injury for arterial reconstruction, after a supracondylar humeral fracture. The management of pediatric elbow fractures accompanying vascular injuries can be technically demanding due to relatively small, delicate structures and concurrent neurovascular network. Nonetheless, a vascular injury should be treated with high level of suspicion and immediate intervention to avoid any limb ischemia or loss. In

  5. Thoracic Stent Graft Implantation for Aortic Coarctation with Patent Ductus Arteriosus via Retroperitoneal Iliac Approach in the Presence of Small Sized Femoral Artery

    Directory of Open Access Journals (Sweden)

    Ozge Korkmaz

    2016-01-01

    Full Text Available Endovascular stent graft implantation is a favorable method for complex aortic coarctation accompanied by patent ductus arteriosus. Herein, an 18-year-old woman with complex aortic coarctation and patent ductus arteriosus was successfully treated by endovascular thoracic stent graft via retroperitoneal approach. The reason for retroperitoneal iliac approach was small sized common femoral arteries which were not suitable for stent graft passage. This case is the first aortic coarctation plus patent ductus arteriosus case described in the literature which is treated by endovascular thoracic stent graft via retroperitoneal approach.

  6. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  7. Total Arterial Off‑pump Coronary Revascularization with a Bilateral ...

    African Journals Online (AJOL)

    Total Arterial Off‑pump Coronary Revascularization with a Bilateral Internal Mammary Artery Y Graft (208 cases). Jun-Feng Yang, Hong-Chao Zhang1, Cheng-Xiong Gu, Hua Wei. INTRODUCTION. AY graft is a graft formed by the left internal mammary artery (LIMA) connected to the left anterior descending (LAD) artery and ...

  8. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    Science.gov (United States)

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. Are the Early Postoperative Outcomes of Coronary Artery Bypass Grafting Surgery in Elderly Women Worse Compared to Men's?

    Directory of Open Access Journals (Sweden)

    Ahmet Yüksel

    Full Text Available Abstract Objective: To investigate the impact of gender difference in early postoperative outcomes in elderly patients (aged 70 or older undergoing coronary artery bypass grafting surgery. Methods: Between October 2009 and December 2013, a total of 223 elderly patients (aged 70 or older undergoing isolated primary coronary artery bypass grafting surgery were included in this retrospective observational cohort study. Patients were divided into two groups according to their gender. The patients' medical records were collected, their baseline preoperative characteristics, operative data, and postoperative outcomes were retrospectively reviewed, and the effect of gender difference in the early postoperative outcomes was analyzed. Results: Group 1 (female patients and Group 2 (male patients consisted of 71 and 152 patients, respectively. Mean age of patients was 74.4±3.6 years (range: 70-84 years. The level of EuroSCORE I, the incidence of hypertension and hyperlipidemia were significantly higher in Group 1, while the rate of smoking was significantly higher in Group 2. Mean postoperative intubation time, length of intensive care unit and hospital stay were longer in female patients than in male patients, but these differences were not statistically significant. No statistically significant difference between two groups in terms of the transfusion of blood products was observed. The rates of in-hospital mortality and major postoperative complications were statistically similar between the two groups. Conclusion: In conclusion, the female gender was not associated with worse early postoperative outcomes in elderly patients undergoing coronary artery bypass grafting surgery.

  10. Development and Evaluation of Care Programs for the Delirium Management in Patients after Coronary Artery Bypass Graft Surgery (CABG

    Directory of Open Access Journals (Sweden)

    Safoora Fallahpoor

    2016-07-01

    Full Text Available Delirium is one of the common problems of cognitive impairment after coronary artery bypass graft surgery (CABG that its prevention, timely detection, and treatment require a care and management program to be controlled. The present research has studied a care program for the management of delirium in patients after coronary artery bypass graft surgery. This research was performed by action research methodology during a fivestage cycle in two groups of 50 persons (without interference and with intervention. In both groups, the patients were evaluated every 8 hours by CAM-ICU tool in hours (6, 14 and 22 for the occurrence of delirium after surgery until they were in Intensive Care Unit (ICU. In the intervention group, the developed program was implemented in three areas of delirium management before, during, and after the surgery. Then, the collected information was analyzed in two groups using descriptive and analytical statistics in SPSS 20 software. Delirium was observed at least once in 68% of patients without the intervention and 38% of patients with intervention after surgery. The ratio of delirium incidence was significantly lower in the intervention group (P<0.05. In addition, the total number of delirium in ICU was significantly lower for patients in the intervention group (P<0.05.The developed program for reducing the incidence of delirium in hospitalized patients after coronary artery bypass graft surgery (CABG was confirmed. This means that its applying will lead to a reduction in delirium.

  11. Vitamin C in prevention of atrial fibrillation after coronary artery bypass graft: double blind randomized clinical trial

    Directory of Open Access Journals (Sweden)

    Mahmoodreza Sarzaeem

    2014-03-01

    Conclusion: Vitamin C is relatively safe, inexpensive, well tolerated and has a low complication. According to the 44% reduction in the incidence of atrial fibrillation in vitamin C patients undergoing coronary artery bypass grafting surgery, this drug can be prescribed as a prophylaxis for prevention of post-CABG atrial fibrillation.

  12. All-cause mortality and major cardiovascular outcomes comparing percutaneous coronary angioplasty versus coronary artery bypass grafting in the treatment of unprotected left main stenosis

    DEFF Research Database (Denmark)

    Laukkanen, Jari A; Kunutsor, Setor K; Niemelä, Matti

    2017-01-01

    Objective: We compared percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) for the treatment of left main coronary artery (LMCA) disease by conducting a systematic review and meta-analysis of randomised controlled trials (RCTs). Methods: RCTs of PCI versus CABG in...

  13. Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries

    International Nuclear Information System (INIS)

    England, Andrew; Butterfield, John S.; McCollum, Charles N.; Ashleigh, Raymond J.

    2008-01-01

    The purpose of this study is to report outcomes following endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA) in patients with ectatic common iliac arteries (CIAs). Of 117 AAA patients treated by EVAR between 1998 and 2005, 87 (74%) had CIAs diameters 18 but <25 mm. All patients were treated with Talent stent-grafts, 114 bifurcated and 3 AUI devices. Departmental databases and patient records were reviewed to assess outcomes. Technical success, iliac-related outcome, and iliac-related reintervention (IRSI) were analyzed. Patients with EVAR extending into the external iliac artery were excluded. Median (range) follow-up for the study group was 24 (1-84) months. Initial technical success was 98% for CIAs <18 mm and 100% for CIAs ≥18 mm (p = 0.551). There were three distal type I endoleaks (two in the ectatic group) and six iliac limb occlusions (one in an ectatic patient); there were no statistically significant differences between groups (p = 0.4). There were nine IRSIs (three stent-graft extensions, six femorofemoral crossover grafts); three of these patients had one or both CIAs ≥18 mm (p = 0.232). One-year freedom from IRSI was 92% ± 3% and 84% ± 9% for the <18-mm and ≥18-mm CIA groups, respectively (p = 0.232). We conclude that the treatment of AAA by EVAR in patients with CIAs 18-24 mm appears to be safe and effective, however, it may be associated with more frequent reinterventions.

  14. Sequential Vein Bypass Grafting is Not Associated with an Increase of Either In-hospital or Mid-term Adverse Events in Off-pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Fucheng Xiao

    2015-01-01

    Full Text Available Background: The impact of sequential vein bypass grafting on clinical outcomes is less known in off-pump coronary artery bypass grafting (CABG. We aimed to evaluate the effects of sequential vein bypass grafting on clinical outcomes in off-pump CABG. Methods: From October 2009 to September 2013 at the Fuwai Hospital, 127 patients with at least one sequential venous graft were matched with 127 patients of individual venous grafts only, using propensity score matching method to obtain risk-adjusted outcome comparison. In-hospital measurement was composite outcome of in-hospital death, myocardial infarction (MI, stroke, requirement for intra-aortic ballon pump (IABP assistance and prolonged ventilation. Major adverse cardiac events (MACEs: Death, MI or repeat revascularization and angina recurrence were considered as mid-term endpoints. Results: No significant difference was observed among the groups in baseline characteristics. Intraoperative mean blood flow per vein graft was 40.4 ml in individual venous grafts groups versus 59.5 ml in sequential venous grafts groups (P < 0.001. There were no differences between individual and sequential venous grafts groups with regard to composite outcome of in-hospital mortality, MI, stroke, IABP assistance and prolonged ventilation (11.0% vs. 14.2%, P = 0.45. Individual in-hospital measurement also did not differ significantly between the two groups. At about four years follow-up, the survival estimates free from MACEs (92.5% vs. 97.3%, P = 0.36 and survival rates free of angina recurrence (80.9% vs. 85.5%, P = 0.48 were similar among individual and sequential venous grafts groups with a mean follow-up of 22.5 months. In the Cox regression analysis, sequential vein bypass grafting was not identified as an independent predictor of both MACEs and angina recurrence. Conclusions: Compared to individual vein bypass grafting, sequential vein bypass grafting was not associated with an increase of either in

  15. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    Science.gov (United States)

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  16. Impact of smoking on early clinical outcomes in patients undergoing coronary artery bypass grafting surgery

    OpenAIRE

    Ji, Qiang; Zhao, Hang; Mei, YunQing; Shi, YunQing; Ma, RunHua; Ding, WenJun

    2015-01-01

    Background To evaluate the impact of persistent smoking versus smoking cessation over one month prior to surgery on early clinical outcomes in Chinese patients undergoing isolated coronary artery bypass grafting (CABG) surgery in a retrospective study. Methods The peri-operative data of consecutive well-documented patients undergoing isolated CABG surgery from January 2007 to December 2013 were investigated and retrospectively analyzed. All included patients were divided into either a non-smo...

  17. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  18. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  19. Coronary Artery Bypass Graft Surgery: The Past, Present, and Future of Myocardial Revascularisation

    Directory of Open Access Journals (Sweden)

    Michael Diodato

    2014-01-01

    Full Text Available The development of the heart-lung machine ushered in the era of modern cardiac surgery. Coronary artery bypass graft surgery (CABG remains the most common operation performed by cardiac surgeons today. From its infancy in the 1950s till today, CABG has undergone many developments both technically and clinically. Improvements in intraoperative technique and perioperative care have led to CABG being offered to a more broad patient profile with less complications and adverse events. Our review outlines the rich history and promising future of myocardial revascularization.

  20. Surveillance Duplex Ultrasonography of Stent Grafts for Popliteal Aneurysms.

    Science.gov (United States)

    Pineda, Danielle M; Troutman, Douglas A; Dougherty, Matthew J; Calligaro, Keith D

    2016-05-01

    Stent grafts, also known as covered stents, have become an increasingly acceptable treatment for popliteal artery aneurysms. However, endovascular exclusion confers lower primary patency compared to traditional open bypass and exclusion. The purpose of this study was to evaluate whether duplex ultrasonography (DU) can reliably diagnose failing stent grafts placed for popliteal artery aneurysms prior to occlusion. Between June 5, 2007, and March 11, 2014, 21 stent grafts (Viabahn; Gore, Flagstaff, Arizona) were placed in 19 patients for popliteal artery aneurysms. All patients had at least 1 follow-up duplex scan postoperatively. Mean follow-up was 28.9 months (9-93 months). Postoperative DU surveillance was performed in our Intersocietal Accreditation Commission noninvasive vascular laboratory at 1 week postprocedure and every 6 months thereafter. Duplex ultrasonography measured peak systolic velocities (PSVs) and ratio of adjacent PSVs (Vr) every 5 cm within the stent graft and adjacent arteries. We retrospectively classified the following factors as "abnormal DU findings": focal PSV > 300 cm/s, uniform PSVs 3.0. These DU criteria were derived from laboratory-specific data that we previously published on failing stent grafts placed for lower extremity occlusive disease. Four of the 21 stent grafts presented with symptomatic graft thrombosis within 6 months of a normal DU. Three of these 4 patients presented with rest pain and underwent thrombectomy (2) or vein bypass (1), and 1 elected for nonintervention for claudication. Our results suggest that surveillance DU using criteria established for grafts placed for occlusive disease may not be useful for predicting stent graft failure in popliteal artery aneurysms. © The Author(s) 2016.

  1. Long-Term Outcomes of Catheter-Directed Thrombolysis for Acute Lower Extremity Occlusions of Native Arteries and Prosthetic Bypass Grafts

    NARCIS (Netherlands)

    Schrijver, A. Marjolein; de Vries, Jean Paul P M; van den Heuvel, Daniel A F; Moll, Frans L.

    2016-01-01

    Background Catheter-directed thrombolysis is a well-accepted treatment for acute lower extremity occlusions of native arteries and bypass grafts. Several variables that affect outcomes of thrombolysis have been identified. The hypothesis of this study was that the long-term outcome after

  2. Hemodynamic analysis of sequential graft from right coronary system to left coronary system.

    Science.gov (United States)

    Wang, Wenxin; Mao, Boyan; Wang, Haoran; Geng, Xueying; Zhao, Xi; Zhang, Huixia; Xie, Jinsheng; Zhao, Zhou; Lian, Bo; Liu, Youjun

    2016-12-28

    Sequential and single grafting are two surgical procedures of coronary artery bypass grafting. However, it remains unclear if the sequential graft can be used between the right and left coronary artery system. The purpose of this paper is to clarify the possibility of right coronary artery system anastomosis to left coronary system. A patient-specific 3D model was first reconstructed based on coronary computed tomography angiography (CCTA) images. Two different grafts, the normal multi-graft (Model 1) and the novel multi-graft (Model 2), were then implemented on this patient-specific model using virtual surgery techniques. In Model 1, the single graft was anastomosed to right coronary artery (RCA) and the sequential graft was adopted to anastomose left anterior descending (LAD) and left circumflex artery (LCX). While in Model 2, the single graft was anastomosed to LAD and the sequential graft was adopted to anastomose RCA and LCX. A zero-dimensional/three-dimensional (0D/3D) coupling method was used to realize the multi-scale simulation of both the pre-operative and two post-operative models. Flow rates in the coronary artery and grafts were obtained. The hemodynamic parameters were also showed, including wall shear stress (WSS) and oscillatory shear index (OSI). The area of low WSS and OSI in Model 1 was much less than that in Model 2. Model 1 shows optimistic hemodynamic modifications which may enhance the long-term patency of grafts. The anterior segments of sequential graft have better long-term patency than the posterior segments. With rational spatial position of the heart vessels, the last anastomosis of sequential graft should be connected to the main branch.

  3. Endovascular repair of arterial iliac vessel wall lesions with a self-expandable nitinol stent graft system.

    Directory of Open Access Journals (Sweden)

    Birger Mensel

    Full Text Available To assess the therapeutic outcome after endovascular repair of iliac arterial lesions (IALs using a self-expandable Nitinol stent graft system.Between July 2006 and March 2013, 16 patients (13 males, mean age: 68 years with a self-expandable Nitinol stent graft. A total of 19 lesions were treated: nine true aneurysms, two anastomotic aneurysms, two dissections, one arteriovenous fistula, two type 1B endoleaks after endovascular aneurysm repair, one pseudoaneurysm, and two perforations after angioplasty. Pre-, intra-, and postinterventional imaging studies and the medical records were analyzed for technical and clinical success and postinterventional complications.The primary technical and clinical success rate was 81.3% (13/16 patients and 75.0% (12/16, respectively. Two patients had technical failure due to persistent type 1A endoleak and another patient due to acute stent graft thrombosis. One patient showed severe stent graft kinking on the first postinterventional day. In two patients, a second intervention was performed. The secondary technical and clinical success rate was 87.5% (14/16 and 93.8% (15/16. The minor complication rate was 6.3% (patient with painful hematoma at the access site. The major complication rate was 6.3% (patient with ipsilateral deep vein thrombosis. During median follow-up of 22.4 months, an infection of the aneurysm sac in one patient and a stent graft thrombosis in another patient were observed.Endovascular repair of various IALs with a self-expandable Nitinol stent graft is safe and effective.

  4. Effects of therapeutic touch on the vital signs of patients before coronary artery bypass graft surgery.

    Science.gov (United States)

    Zare, Zahra; Shahsavari, Hooman; Moeini, Mahin

    2010-01-01

    Currently healthy heart word considered to be the objective of community health applications in many countries of the world because cardiovascular diseases are the most important factor in mortality of humans, worldwide. Coronary artery bypass graft surgery is one of the most common surgery procedures for these patients. The purpose of this study is to assess the impact of therapeutic touch on medical vital signs of patients before coronary artery bypass graft surgery. The present study is a clinical trial with 44 samples that were selected by easy sampling method and based on two separate lists of random numbers for both men and women; they were divided into two groups. In the therapeutic touch group, intervention therapy was applied on patents for 20 minutes. Data was analyzed using descriptive and inferential statistics. Test results showed that there was a significant difference between the mean pulse rate before and after intervention in both groups (p touch therapy as a safe and effective intervention on the patients which were revealed in this study, this technique can be used as a simple, cheap and applicable technique in all health care centers to help these patients.

  5. Antiplatelet therapy at the time of coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Kremke, Michael; Jensen, Mariann Tang; Bak, Mikkel

    2013-01-01

    OBJECTIVES: The purpose of this multicentre cohort study was to examine the relationship between antiplatelet therapy (APT) at the time of coronary artery bypass grafting (CABG) and postoperative bleeding complications, transfusion requirements and adverse cardiovascular events. METHODS: A matched...... Denmark Heart Registry. RESULTS: Of the 6350 patients enrolled, 1846 (29%) had been exposed to aspirin or clopidogrel within 5 days prior to CABG (the APT group). Matching with the remaining 4504 (71%) patients of the control group resulted in 1132 pairs of patients. Patients in the APT group had greater...... postoperative bleeding (OR: 2.08, 95% CI: 1.55-2.80). Overall, preoperative APT had no significant effect on postoperative 30-day mortality, incidence of myocardial infarction, stroke or need for dialysis. CONCLUSIONS: Preoperative APT is associated with increased bleeding and greater transfusion requirements...

  6. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  7. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    Energy Technology Data Exchange (ETDEWEB)

    Becher, Tobias, E-mail: Tobias.Becher@umm.de [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Mashayekhi, Kambis [Division of Cardiology and Angiology II, University Heart Center Freiburg Bad Krozingen, Bad Krozingen (Germany); Borggrefe, Martin; Akin, Ibrahim [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2016-12-15

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use.

  8. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    International Nuclear Information System (INIS)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-01-01

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use

  9. Sustained Thromboresistant Bioactivity with Reduced Intimal Hyperplasia of Heparin-Bonded Polytetrafluoroethylene Propaten Graft in a Chronic Canine Femoral Artery Bypass Model.

    Science.gov (United States)

    Freeman, John; Chen, Aaron; Weinberg, Roy J; Okada, Tamuru; Chen, Changyi; Lin, Peter H

    2018-05-01

    Bypass graft thrombosis remains a significant mode of failure in prosthetic graft revascularization. The purpose of this investigation was to evaluate the long-term thromboresistant effect of heparin-bonded expanded polytetrafluoroethylene (ePTFE) graft using Carmeda BioActive Surface technology in a canine model. Bilateral femorofemoral artery bypass grafts with ePTFE grafts were performed in 25 adult grayhound dogs. In each animal, a heparin-bonded ePTFE graft (Propaten, WL Gore) was placed on one side, whereas a control nonheparin graft was placed on the contralateral side. The graft patency was assessed at 1, 6, 12, 18, and 24 months (n = 5 per group) following the bypass. Heparin bioactivity of the graft material was analyzed. The effect of intimal hyperplasia was also assessed. All bypass grafts were patent at 1 month. Significantly greater patency rates were noted in the Propaten group compared to the control group at 12, 18, and 24 months, which were 84%, 80%, and 80% vs. 55%, 35%, and 20%, respectively (P  0.05). Heparin-bonded ePTFE graft provides a thromboresistant surface and reduced anastomotic intimal hyperplasia at 2 years. The stable heparin bioactivity of the Propaten graft confers an advantage in long-term graft patency. Copyright © 2017 The Author(s). Published by Elsevier Inc. All rights reserved.

  10. Potential advantages of treatment of transplanted saphenous vein aorto-coronary artery bypass grafts with beta irradiation to prevent graft occlusion.

    Science.gov (United States)

    Smith, R G

    1997-01-01

    Intimal proliferation or Neointimal hyperplasia (NIH) is a vascular lesion that often arises in arteries after balloon angioplasty or other vessel wall injuries. FIH is a vascular lesion that develops in autologous saphenous vein grafts (SVG) after transplantation into the aorto-coronary circulation or the peripheral vascular circulation. FIH shares elements of smooth muscle migration, proliferation and fibrous tissue deposition in common with nibrointimal proliferation (NIH). Either NIH of a coronary artery or FIH of a SVG obstruct the vascular lumen and result in myocardial dysfunction. Local radiotherapy has been used for several decades to reduce the post-operative recurrence of the fibrovascular proliferations of pterygia and keloids. Similarly, in animal and human experiments, endovascular radiotherapy has been shown to reduce arterial smooth muscle proliferation. Consideration of the similarities of vascular smooth muscle cell proliferation in NIH and FIH leads one to suggest that endovascular beta irradiation can reduce FIH as well as it reduces NIH. The goal of such treatment is to achieve a clinically significant decrease in the morbidity and mortality resulting from SVG occlusions. The potential for large reduction of the consequences of SVG occlusion, the very large number of patients at risk, and the simplicity of the proposed intervention encourages prompt scientific evaluation of this technique.

  11. Follow-up of coronary artery bypass graft patency: diagnostic efficiency of high-pitch dual-source 256-slice MDCT findings.

    Science.gov (United States)

    Yuceler, Zeyneb; Kantarci, Mecit; Yuce, Ihsan; Kizrak, Yesim; Bayraktutan, Ummugulsum; Ogul, Hayri; Kiris, Adem; Celik, Omer; Pirimoglu, Berhan; Genc, Berhan; Gundogdu, Fuat

    2014-01-01

    Our aim was to evaluate the diagnostic accuracy of 256-slice, high-pitch mode multidetector computed tomography (MDCT) for coronary artery bypass graft (CABG) patency. Eighty-eight patients underwent 256-slice MDCT angiography to evaluate their graft patency after CABG surgery using a prospectively synchronized electrocardiogram in the high-pitch spiral acquisition mode. Effective radiation doses were calculated. We investigated the diagnostic accuracy of high-pitch, low-dose, prospective, electrocardiogram-triggering, dual-source MDCT for CABG patency compared with catheter coronary angiography imaging findings. A total of 215 grafts and 645 vessel segments were analyzed. All graft segments had diagnostic image quality. The proximal and middle graft segments had significantly (P < 0.05) better mean image quality scores (1.18 ± 0.4) than the distal segments (1.31 ± 0.5). Using catheter coronary angiography as the reference standard, high-pitch MDCT had the following sensitivity, specificity, positive predictive value, and negative predictive value of per-segment analysis for detecting graft patency: 97.1%, 99.6%, 94.4%, and 99.8%, respectively. In conclusion, MDCT can be used noninvasively with a lower radiation dose for the assessment of restenosis in CABG patients.

  12. No benefit of intraoperative whole blood sequestration and autotransfusion during coronary artery bypass grafting : results of a randomized clinical trial

    NARCIS (Netherlands)

    Ramnath, A N; Naber, H R; de Boer, A; Leusink, J A

    OBJECTIVES: In a randomized clinical trial of patients undergoing elective coronary artery bypass grafting, we evaluated the effect of intraoperative whole blood sequestration and autotransfusion on postoperative blood loss and the use of allogeneic blood products. METHODS: Male patients were

  13. Preoperative Hba1c level in prediction of short-term morbidity and mortality outcomes following coronary artery bypass grafting surgery

    Directory of Open Access Journals (Sweden)

    Ümit Arslan

    2015-05-01

    Conclusion ― We concluded that in those diabetic patients that elective coronart artery bypass graft is applied, highly reactive HbA1c levels (HbA1c ≥7, may indicate morbitity in the early stages of post operation.

  14. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  15. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    International Nuclear Information System (INIS)

    Joshi, Abhay B.; Kalange, Ashok E.; Bodas, Dhananjay; Gangal, S.A.

    2010-01-01

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  16. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  17. Hyperhomocysteinemia and mortality after coronary artery bypass grafting.

    Directory of Open Access Journals (Sweden)

    Domenico Girelli

    Full Text Available BACKGROUND: The independent prognostic impact, as well as the possible causal role, of hyperhomocysteinemia (HHcy in coronary artery disease (CAD is controversial. No previous study specifically has addressed the relationship between HHcy and mortality after coronary artery bypass grafting (CABG surgery. The aim of this study is to evaluate the prognostic impact of HHcy after CABG surgery. METHODOLOGY AND PRINCIPAL FINDINGS: We prospectively followed 350 patients who underwent elective CABG between May 1996 and May 1999. At baseline, fasting total homocysteine (tHcy levels were measured in all participants, and a post-methionine loading (PML test was performed in 77.7% of them (n = 272. After a median follow-up of 58 months, 33 patients (9.4% had died, 25 because of cardiovascular events. HHcy, defined by levels higher than the 90th percentile (25.2 micromol/L of the population's distribution, was significantly associated to total and cardiovascular mortality (P = 0.018 [log-rank test 5.57]; P = 0.002 [log-rank test 9.76], respectively. The PML test had no prognostic value. After multiple adjustment for other univariate predictors by Cox regression, including statin therapy (the most powerful predictor in uni-/multivariate analyses, high-sensitivity C Reactive Protein (hs-CRP levels, and all known major genetic (MTHFR 677C-->T polymorphism and non-genetic (B-group vitamin status and renal function tHcy determinants, HHcy remained an independent prognostic factor for mortality (HRs: 5.02, 95% CIs 1.88 to 13.42, P = 0.001. CONCLUSIONS: HHcy is an important prognostic marker after CABG, independent of modern drug therapy and biomarkers.

  18. The New York risk score for in-hospital and 30-day mortality for coronary artery bypass graft surgery.

    Science.gov (United States)

    Hannan, Edward L; Farrell, Louise Szypulski; Wechsler, Andrew; Jordan, Desmond; Lahey, Stephen J; Culliford, Alfred T; Gold, Jeffrey P; Higgins, Robert S D; Smith, Craig R

    2013-01-01

    Simplified risk scores for coronary artery bypass graft surgery are frequently in lieu of more complicated statistical models and are valuable for informed consent and choice of intervention. Previous risk scores have been based on in-hospital mortality, but a substantial number of patients die within 30 days of the procedure. These deaths should also be accounted for, so we have developed a risk score based on in-hospital and 30-day mortality. New York's Cardiac Surgery Reporting System was used to develop an in-hospital and 30-day logistic regression model for patients undergoing coronary artery bypass graft surgery in 2009, and this model was converted into a simple linear risk score that provides estimated in-hospital and 30-day mortality rates for different values of the score. The accuracy of the risk score in predicting mortality was tested. This score was also validated by applying it to 2008 New York coronary artery bypass graft data. Subsequent analyses evaluated the ability of the risk score to predict complications and length of stay. The overall in-hospital and 30-day mortality rate for the 10,148 patients in the study was 1.79%. There are seven risk factors comprising the score, with risk factor scores ranging from 1 to 5, and the highest possible total score is 23. The score accurately predicted mortality in 2009 as well as in 2008, and was strongly correlated with complications and length of stay. The risk score is a simple way of estimating short-term mortality that accurately predicts mortality in the year the model was developed as well as in the previous year. Perioperative complications and length of stay are also well predicted by the risk score. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Analysis of transit time flow of the right internal thoracic artery anastomosed to the left anterior descending artery compared to the left internal thoracic artery

    Science.gov (United States)

    Milani, Rodrigo; de Moraes, Daniela; Sanches, Aline; Jardim, Rodrigo; Lumikoski, Thais; Miotto, Gabriela; Santana, Vitor Hugo; Brofman, Paulo Roberto

    2014-01-01

    Introduction We evaluated with transit time flow the performance of the right and left thoracic arteries when used as a graft for the left anterior descending artery. Methods Fifty patients undergoing surgery for myocardial revascularization without cardiopulmonary bypass were divided into two groups. In group A patients received graft of right internal mammary artery to the anterior interventricular branch. In group B patients received graft of left internal mammary artery to the same branch. At the end of the operation the flow was assessed by measuring transit time. Results In group A, mean age was 60.6±9.49 years. The average height and weight of the group was 80.4±10.32 kg and 169.2±6.86 cm. The average number of grafts per patient in this group was 3.28±1.49. The mean flow and distal resistance obtained in right internal thoracic artery was 42.1±23.4 ml/min and 2.8±0.9 respectively. In group B, the mean age was 59.8±9.7 years. The average height and weight of this group was 77.7±14.22 kg and 166.0±8.2 cm. The average number of grafts per patient in this group was 3.08 ±0.82. The mean flow and distal resistance observed in this group was 34.2±19.1 ml/min and 2.0±0.7. There were no deaths in this series. Conclusion Right internal mammary artery presented a similar behavior to left internal mammary artery when anastomosed to the anterior interventricular branch of the left coronary artery. There was no statistical difference between the measured flow obtained between both arteries. PMID:25140463

  20. Safety of Perioperative Aprotinin Administration During Isolated Coronary Artery Bypass Graft Surgery: Insights From the ART (Arterial Revascularization Trial).

    Science.gov (United States)

    Benedetto, Umberto; Altman, Douglas G; Gerry, Stephen; Gray, Alastair; Lees, Belinda; Angelini, Gianni D; Flather, Marcus; Taggart, David P

    2018-03-03

    There is still uncertainty about the safety of aprotinin for coronary artery bypass graft surgery. The ART (Arterial Revascularization Trial) was designed to compare survival after bilateral versus single internal thoracic artery grafting. Many of the ART patients (≈30%) received perioperative aprotinin. We investigated the association between perioperative aprotinin administration and short-term (in-hospital) and long-term outcomes by performing a post hoc analysis of the ART. Among patients enrolled in the ART (n=3102) from 2004 to 2007, we excluded those who did not undergo surgery (n=18) and those with no information about use of perioperative aprotinin (n=9). Finally, 836 of 3076 patients (27%) received aprotinin. Propensity matching was used to select 536 pairs for final comparison. Aprotinin was also associated with an increased risk of hospital mortality (9 [1.7%] versus 1 [0.2%]; odds ratio, 9.12; 95% confidence interval [CI], 1.15-72.2; P =0.03), intra-aortic balloon pump insertion (37 [6.9%] versus 17 [3.2%]; odds ratio, 2.26; 95% CI, 1.26-4.07; P =0.006), and acute kidney injury (102 [19.0%] versus 76 [14.2%]; odds ratio, 1.42; 95% CI, 1.03-1.97; P =0.03). Aprotinin was not associated with a lower incidence of transfusion (37 [6.9%] versus 28 [5.2%]; odds ratio, 1.34; 95% CI, 0.81-2.23; P =0.25) and reexploration (26 [4.9%] versus 19 [3.5%]; hazard ratio, 1.39; 95% CI, 0.76-2.53; P =0.28). At 5 years, all-cause mortality was significantly increased in the aprotinin group (56 [10.6%] versus 38 [7.3%]; hazard ratio, 1.51; 95% CI, 1.0-2.28; P =0.045). In the present post hoc ART analysis, aprotinin was associated with a significantly increased risk of early and late mortality. URL: http://www.isrctn.com. Unique identifier: ISRCTN46552265. © 2018 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

  1. Vascugraft polyurethane arterial prosthesis as femoro-popliteal and femoro-peroneal bypasses in humans: pathological, structural and chemical analyses of four excised grafts.

    Science.gov (United States)

    Zhang, Z; Marois, Y; Guidoin, R G; Bull, P; Marois, M; How, T; Laroche, G; King, M W

    1997-01-01

    Following positive results obtained in in vitro studies and in vivo implantations in animals, a clinical trial using the Vascugraft polyurethane arterial prosthesis as a below-knee substitute was undertaken in 15 patients. Eight grafts became occluded during the first year, and segments from four of them were explanted and made available for pathological, structural and chemical investigations. The implantation periods ranged from 21 to 358 days. Failures were associated with kinking (one case), possible anastomotic mismatch between the graft and the artery (one case), and poor run-off (two cases). No organized collagenous internal encapsulation was noted; however, endothelial-like cells were observed at the anastomotic site of one graft. No significant structural degradation of the prostheses was observed in those grafts implanted for 21, 38 and 46 days. Some deteriorations in the fibrous structure were observed on the external surface of the prosthesis implanted for 358 days. High-resolution carbon C1s analysis by ESCA demonstrated a 60 to 80% decrease in carbonate content on the surface of all explanted prostheses. Chemical analyses of each polyurethane graft by IR, SEC and DSC revealed no significant chemical changes. The clinical performance of the Vascugraft prosthesis for below-knee implantation proved to be no more impressive than that of expanded polytetrafluorethylene, the currently accepted reference. The decision by B. Braun Melsungen AG to end this program is therefore to be regarded as highly professional.

  2. Coronary artery calcifications in renal graft recipients at the time of transplantation.

    Science.gov (United States)

    Serafin, Zbigniew; Nawrocka, Elzbieta; Thabit, Sinjab A; Lasek, Władysław; Włodarczyk, Zbigniew

    2007-05-01

    Coronary artery calcifications (CACs) represent an important risk factor of coronary artery disease in the general population. The purpose of the study was to determine the amount of CAC, including calcium mass, in renal graft recipients early after transplantation. Forty-nine patients aged 43.7+/-9.8 years underwent CAC determination with multi-detector row computed tomography within two weeks after transplantation. The calcium scores were compared with the clinical and laboratory data of the subjects. CACs were detected in 73% of the subjects. The mean calcium score (CS) was 500.8+/-1100.4 and the mean calcium mass (CM) 127.0+/-228.6 mg. Presence of diabetes, duration of hypertension, and diastolic blood pressure (DBP) were significantly associated with the presence of CAC in univariate analysis. CS and CM positively correlated with duration of hypertension, time on dialysis, and pulse pressure (PP) and negatively with DBP. In multiple regression analysis the duration of hypertension, DBP, and PP were identified as independent predictors of CAC presence (p<0.01), while the time on dialysis and DBP were independent predictors of CAC severity (p<0.02). The results suggest that hypertension may play a crucial role in the development of coronary artery calcifications in end-stage renal disease patients, but the nature of the relation between CAC and blood pressure needs further investigation.

  3. Diabetes patients show different time-course of myocardial perfusion improvement after coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Lee, J. J.; Seok, J. W.; Eo, J. S.

    2005-01-01

    Diabetes mellitus is an independent risk factor of cardiovascular disease. Diabetes is known to cause microangiopathy. The microangiopathy is hardly detectable on the coronary angiography. Myocardial perfusion imaging shows the resultant perfusion status which reflects the microangiopathy. For patients who underwent revascularization, the microangiopathy could affect the myocardial perfusion improvement. Diabetes patients probably experience the different myocardial perfusion improvement as compared to the non-diabetes patients although they have similar angiographic findings. The aim of this study is to find out whether there is a time-course difference of perfusion improvement between the diabetes and non diabetes patients who showed patent angiographic findings after coronary artery grafting surgery (CABG). A total of 129 patients who underwent coronary artery bypass grafting surgery were enrolled in this study. Myocardial SPECTs performed at previous, short-term (3 month), and mid-term (1 year) to CABG. One-year follow up angiography was done 411±121 days after surgery. Graft patency was determined according to the FitzGibbon et al. Segments were assigned to vascular territories using a 20 segment model. The segments of excellent patency were included in this study. Time course differences of concerned segments were analyzed using RMANOVA. The number of segments enrolled was 764 of diabetes and 1083 of non-diabetes. At short-term follow up, reversibility score was 2.8±8.1% in diabetes and 0.3±7.5% in non-diabetes. At long-term follow up, reversibility score was 1.8±8.0% in diabetes and 0.1±7.3% in non-diabetes. The time-course of reversibility score was significantly different between the diabetes and non diabetes (p<0.001) Diabetic segments showed high residual reversibility score than non-diabetic segments after CABG although the angiographic finding was patent in both groups. This result is maybe attributable to microangiopathy induced by diabetes

  4. Cumulative incidence for wait-list death in relation to length of queue for coronary-artery bypass grafting: a cohort study

    Directory of Open Access Journals (Sweden)

    Levy Adrian R

    2006-08-01

    Full Text Available Abstract Background In deciding where to undergo coronary-artery bypass grafting, the length of surgical wait lists is often the only information available to cardiologists and their patients. Our objective was to compare the cumulative incidence for death on the wait list according to the length of wait lists at the time of registration for the operation. Methods The study cohort included 8966 patients who registered to undergo isolated coronary-artery bypass grafting (82.4% men; 71.9% semi-urgent; 22.4% non-urgent. The patients were categorized according to wait-list clearance time at registration: either "1 month or less" or "more than 1 month". Cumulative incidence for wait-list death was compared between the groups, and the significance of difference was tested by means of regression models. Results Urgent patients never registered on a wait list with a clearance time of more than 1 month. Semi-urgent patients registered on shorter wait lists more often than non-urgent patients (79.1% vs. 44.7%. In semi-urgent and non-urgent patients, the observed proportion of wait-list deaths by 52 weeks was lower in category "1 month or less" than in category "more than 1 month" (0.8% [49 deaths] vs. 1.6% [39 deaths], P P Conclusion Long wait lists for coronary-artery bypass grafting are associated with increased probability that a patient dies before surgery. Physicians who advise patients where to undergo cardiac revascularization should consider the risk of pre-surgical death that is associated with the length of a surgical wait list.

  5. Indium-111 platelet imaging for detection of platelet deposition in abdominal aneurysms and prosthetic arterial grafts

    International Nuclear Information System (INIS)

    Ritchie, J.L.; Stratton, J.R.; Thiele, B.; Haminton, G.W.; Warrick, L.N.; Huang, T.W.; Harker, L.A.

    1981-01-01

    Thirty-four platelet imaging studies were performed in 23 patients to determine whether platelet deposition could be detected in patients with vascular aneurysms (18 patients) or in patients in whom Dacron prosthetic grafts had been placed (5 patients). In patients in whom abnormal platelet deposition was detected, the effect of administration of platelet-active drugs on platelet deposition was examined. Of the 18 patients with an aneurysm, 12 had equivocally positive studies on initial imaging and 2 had equivocally positive images. Of five patients with Dacron arterial grafts in place, four had diffuse platelet deposition in the grafts; the fifth patient had a platelet deposition only in a pseudoaneurysm. Eight patients with an abdominal aneurysm and positive or equivocally positive baseline images were restudied during platelet-active drug therapy either with aspirin plus dipyridamole (seven patients) or with sulfinpyrazone (four patients). No patient studied during treatment with aspirin plus dipyridamole had detectably decreased platelet deposition compared with baseline determinations. In contrast, two of four patients studied while receiving sulfinpyrazone showed decreased platelet deposition. Thus, platelet imaging may be of value for studying platelet physiology in vivo and for assessing platelet-active drugs and the thrombogenicity of prosthetic graft materials in human beings

  6. Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.

    Science.gov (United States)

    Xie, Zhiyi; Zhang, Zhenyu; Xu, Yuan; Zhou, Hua; Wu, Sheng; Wang, Zhong

    2018-06-01

    In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types. We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups. In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (Ppressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (Parm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5). Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test

  7. The effects of fenoldopam on coronary conduit blood flow after coronary artery bypass graft surgery.

    LENUS (Irish Health Repository)

    Halpenny, M

    2012-02-03

    OBJECTIVE: To quantify the effects of fenoldopam, 0.1 microg\\/kg\\/min, on left internal mammary artery (LIMA) and saphenous vein blood flow after coronary anastomosis. DESIGN: Prospective, randomized, double-blind, placebo-controlled trial. SETTING: University teaching hospital, single institution. PARTICIPANTS: Thirty-one American Society of Anesthesiologists III patients undergoing elective coronary revascularization. INTERVENTIONS: A perivascular ultrasonic flow probe (Linton Instrumentation, Norfolk, UK) was placed around the LIMA and saphenous vein graft after coronary anastomosis. MEASUREMENTS AND MAIN RESULTS: Immediately before and at 5-minute intervals for 15 minutes after starting the infusion, blood flow was measured in the LIMA and one saphenous vein graft using a transit time ultrasonic flow probe. Heart rate, blood pressure, and central venous pressure were documented at these time points. Administration of fenoldopam, 0.1 microg\\/kg\\/min, did not alter heart rate or blood pressure. A small, nonsignificant increase in LIMA blood flow occurred during the 15-minute study period (30 +\\/- 12 to 35 +\\/- 10 mL\\/min) in patients who received fenoldopam. No significant changes occurred in the placebo group. CONCLUSIONS: The findings indicate that fenoldopam, 0.1 microg\\/kg\\/min, did not influence coronary conduit blood flow to a clinically significant extent. The small increase in LIMA blood flow may be of greater importance in high-risk patients or in the prevention of coronary arterial spasm.

  8. Predictors of inotrope use in patients undergoing concomitant coronary artery bypass graft (CABG and aortic valve replacement (AVR surgeries at separation from cardiopulmonary bypass (CPB

    Directory of Open Access Journals (Sweden)

    Nelson William B

    2009-06-01

    Full Text Available Abstract Background Left ventricular dysfunction is common after coronary artery bypass graft and valve replacement surgeries and is often treated with inotropic drugs to maintain adequate hemodynamic status. In this study, we aimed to identify the demographic, clinical, laboratory, echocardiographic and hemodynamic factors that are associated with use of inotropic drugs in patients undergoing concomitant coronary artery bypass graft and aortic valve replacement surgery. Methods The study included 97 patients who had undergone concomitant coronary artery bypass graft and aortic valve replacement at Regions Hospital, University of Minnesota Medical School from January 2006 to December 2008. All data were collected retrospectively after reviewing electronic medical records. Inotropic support was defined as the use of dopamine [greater than or equal to] 5 ug/kg/min; any dose of epinephrine, norepinephrine, dobutamine, and milrinone at the separation from cardiopulmonary bypass. Results Inotropic support was used in a total of 50 patients (52% at the separation from cardiopulmonary bypass. Average age of the patients requiring inotropic support was 72.2 +/- 8.8 years. The study identified four significant, independent predictors of inotrope use: (1 Cardiac index [less than or equal to]2.5 L/min/m2, (2 LVEDP [greater than or equal to] 20 mm Hg, (3 LVEF [less than or equal to]40%, and (4 CKD stage 3 to 5. Conclusion We identified four independent risk factors for postoperative use of inotropic support in patients undergoing concomitant coronary artery bypass graft and arotic valve replacement surgery at the separation from cardiopulmonary bypass. The study results will be helpful to prospectively identify patients who will likely to require inotropic support at the separation from cardiopulmonary bypass.

  9. Natural History of Moderate Coronary Artery Stenosis After Surgical Revascularization.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Olivares, Gabriel; Ravichandren, Kirthi; Koprivanac, Marijan; Bakaeen, Faisal G; Sabik, Joseph F

    2018-03-01

    It remains controversial whether grafting moderately stenosed coronary arteries (MSCAs) influences native-vessel disease progression and whether grafting may protect against late myocardial ischemia. From 1972 to 2011, 55,567 patients underwent primary isolated coronary artery bypass grafting (CABG); 1,902 had a single coronary artery with angiographically moderate (50% to 69%) stenosis and ≥1 postoperative angiogram. Disease progression was studied in 489 nongrafted, 371 internal thoracic artery (ITA)-grafted, and 957 saphenous vein (SV)-grafted MSCAs, as well as patency of 376 ITA and 1,016 SV grafts to these MSCAs. At 1, 5, 10, and 15 years, native-vessel disease progressed from moderate to severe stenosis/occlusion in 32%, 52%, 66%, and 72% of nongrafted MSCAs; 55%, 73%, 84%, and 87% of ITA-grafted MSCAs; and 67%, 82%, 90%, and 92% of SV-grafted MSCAs. After adjusting for patient characteristics, MSCA disease progressed 3.6 times faster with ITA and 10 times faster with SV grafting compared with nongrafting. At these same time points, occlusion of ITA grafts to MSCAs was 8%, 9%, 11%, and 15% and for SV grafts, 13%, 32%, 46%, and 56%; protection from myocardial ischemia by ITA-grafted versus nongrafted MSCAs was 29%, 47%, 59%, and 61%. Most MSCAs progress to severe stenosis or occlusion in the long term. Progression is faster in grafted than nongrafted MSCAs, more so with SV than ITA grafts. However, ITA grafts to such arteries have excellent patency, providing long-term protection from myocardial ischemia. Therefore, ITA grafting of MSCAs should be considered. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. Evaluation of aortocoronary bypass graft patency by reconstructed CT image

    International Nuclear Information System (INIS)

    Kawakita, Seizaburo; Koide, Takashi; Saito, Yoshio; Yamamoto, Tadao; Iwasaki, Tadaaki

    1982-01-01

    Ten patients were examined in the period of three months from January to March 1981. The patients were operated from 1 month to 7 years before CT. A bypass to the left anterior descending artery (LAD) was grafted in 10 cases, 2 to the right coronary artery (RCA), 4 to an obtuse marginal artery (OM), and 1 to a diagonal artery. Image reconstruction was performed in 10 cases by using an image analytical computer Evaluskop. Appropriate planes for reconstruction were selected by trial and error methods upon observation of CT images. When gained picture of a graft course coincided with surgical records or angiography, the work of building images was concluded. On cross section, grafts to LAD were visualized in all 10 cases: 9 in the entire course and 1 in a proximal part of the graft. Two to RCA, 4 to OM and 1 to a diagonal were also successfully visualized. Reconstruction of graft images succeeded in 9 grafts of 6 cases. The course of a graft could be pursued from the proximal to the distal end adjacent to the cardiac chamber. The picture of a bypass to LAD was visualized in 6 of 10 grafts. Two bypass to RCA could be depicted, and 1 to OM was also found. However 3 to OM and 1 to a diagonal failed to be visualized throughout their courses in reconstructed images. I think that the causes of faillure mainly depended upon the course of the graft. When a graft was running arc-like surrounding the heart chamber, it was very difficult to depict its entire length in reconstructed images, though the graft could be detected in cross sections. These preliminary studies indicated that reconstruction of CT images had some benefits for the pursuit of graft courses. (J.P.N.)

  11. Management of patients with hematological malignancies undergoing coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Deepak Borde

    2013-01-01

    Full Text Available The number of patients with a previously diagnosed malignancy who need cardiac surgery is increasing. Patients with hematological malignancies represent only 0.38% of all patients undergoing cardiac surgery. The literature in this subset of patients is limited to only a few retrospective case series, with limited number of patients undergoing emergency cardiac surgery. We describe three cases with hematological malignancies namely chronic myelogenous leukemia, acute promyelocytic leukemia and chronic lymphocytic leukemia presenting for coronary artery bypass grafting (CABG. Two patients were taken up for emergency CABG in view of ongoing ischemia, one of them was on preoperative intra-aortic balloon pump support. No mortality was observed. Two patients needed transfusion of blood products which was guided by thromboelastography. One patient developed superficial sternal wound infection requiring antibiotic therapy.

  12. Submillimeter Diameter Poly(Vinyl Alcohol) Vascular Graft Patency in Rabbit Model

    Science.gov (United States)

    Cutiongco, Marie F. A.; Kukumberg, Marek; Peneyra, Jonnathan L.; Yeo, Matthew S.; Yao, Jia Y.; Rufaihah, Abdul Jalil; Le Visage, Catherine; Ho, Jackie Pei; Yim, Evelyn K. F.

    2016-01-01

    Microvascular surgery is becoming a prevalent surgical practice. Replantation, hand reconstruction, orthopedic, and free tissue transfer procedures all rely on microvascular surgery for the repair of venous and arterial defects at the millimeter and submillimeter levels. Often, a vascular graft is required for the procedure as a means to bridge the gap between native arteries. While autologous vessels are desired for their bioactivity and non-thrombogenicity, the tedious harvest process, lack of availability, and caliber or mechanical mismatch contribute to graft failure. Thus, there is a need for an off-the-shelf artificial vascular graft that has low thrombogenic properties and mechanical properties matching those of submillimeter vessels. Poly(vinyl alcohol) hydrogel (PVA) has excellent prospects as a vascular graft due to its bioinertness, low thrombogenicity, high water content, and tunable mechanical properties. Here, we fabricated PVA grafts with submillimeter diameter and mechanical properties that closely approximated those of the rabbit femoral artery. In vitro platelet adhesion and microparticle release assay verified the low thrombogenicity of PVA. A stringent proof-of-concept in vivo test was performed by implanting PVA grafts in rabbit femoral artery with multilevel arterial occlusion. Laser Doppler measurements indicated the improved perfusion of the distal limb after implantation with PVA grafts. Moreover, ultrasound Doppler and angiography verified that the submillimeter diameter PVA vascular grafts remained patent for 2 weeks without the aid of anticoagulant or antithrombotics. Endothelial cells were observed in the luminal surface of one patent PVA graft. The advantageous non-thrombogenic and tunable mechanical properties of PVA that are retained even in the submillimeter diameter dimensions support the application of this biomaterial for vascular replacement in microvascular surgery. PMID:27376059

  13. Current Strategies for the Manufacture of Small Size Tissue Engineering Vascular Grafts

    Directory of Open Access Journals (Sweden)

    Michele Carrabba

    2018-04-01

    Full Text Available Occlusive arterial disease, including coronary heart disease (CHD and peripheral arterial disease (PAD, is the main cause of death, with an annual mortality incidence predicted to rise to 23.3 million worldwide by 2030. Current revascularization techniques consist of angioplasty, placement of a stent, or surgical bypass grafting. Autologous vessels, such as the saphenous vein and internal thoracic artery, represent the gold standard grafts for small-diameter vessels. However, they require invasive harvesting and are often unavailable. Synthetic vascular grafts represent an alternative to autologous vessels. These grafts have shown satisfactory long-term results for replacement of large- and medium-diameter arteries, such as the carotid or common femoral artery, but have poor patency rates when applied to small-diameter vessels, such as coronary arteries and arteries below the knee. Considering the limitations of current vascular bypass conduits, a tissue-engineered vascular graft (TEVG with the ability to grow, remodel, and repair in vivo presents a potential solution for the future of vascular surgery. Here, we review the different methods that research groups have been investigating to create TEVGs in the last decades. We focus on the techniques employed in the manufacturing process of the grafts and categorize the approaches as scaffold-based (synthetic, natural, or hybrid or self-assembled (cell-sheet, microtissue aggregation and bioprinting. Moreover, we highlight the attempts made so far to translate this new strategy from the bench to the bedside.

  14. A Variant in COX-2 Gene Is Associated with Left Main Coronary Artery Disease and Clinical Outcomes of Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Hanning Liu

    2017-01-01

    Full Text Available As a particular severe phenotype of coronary artery disease (CAD, left main coronary artery disease (LMCAD is heritable. Genetic variants related to prostaglandin metabolism are associated with LMCAD. Cyclooxygenase-2 (COX-2, a key synthase in prostaglandin pathways, displays high density in atherosclerotic lesions and promotes early atherosclerosis in CAD progression. We hypothesized that genetic variants in COX-2 gene contribute to LMCAD phenotype susceptibility compared to more peripheral coronary artery disease (MPCAD. In this study, we genotyped COX-2 rs5275, rs5277, and rs689466 of 1544 CAD patients undergoing coronary artery bypass grafting (CABG and found that rs5277 C allele carriage was associated with LMCAD (adjusted OR: 1.590; 95% CI: 1.103~2.291; p=0.013. Furtherly, long-term follow-up data suggested that rs5277 C allele carriage increased risk of major adverse cardiac and cerebrovascular events (MACCE in the whole cohort (adjusted HR: 1.561; 95% CI: 1.025~2.377; p=0.038 and LMCAD subgroup (adjusted HR: 2.014; 95% CI: 1.036~3.913; p=0.039 but not in MPCAD subgroup (adjusted HR: 1.375; 95% CI: 0.791~2.392; p=0.259. In conclusion, we demonstrate that COX-2 rs5277 C allele increases the risk of left main coronary artery lesion and is also correlated with poor prognosis of LMCAD patients with CABG therapy.

  15. Perioperative risk factors for prolonged mechanical ventilation and tracheostomy in women undergoing coronary artery bypass graft with cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Zahra S Faritous

    2011-01-01

    Full Text Available Background: Prolonged mechanical ventilation is an important recognized complication occurring during cardiovascular surgery procedures. This study was done to assess the perioperative risk factors related to postoperative pulmonary complications and tracheostomy in women undergoing coronary artery bypass graft with cardiopulmonary bypass. Methods: It was a retrospective study on 5,497 patients, including 31 patients with prolonged ventilatory support and 5,466 patients without it; from the latter group, 350 patients with normal condition (extubated in 6-8 hours without any complication were selected randomly. Possible perioperative risk factors were compared between the two groups using a binary logistic regression model. Results: Among the 5,497 women undergoing coronary artery bypass graft (CABG, 31 women needed prolonged mechanical ventilation (PMV, and 15 underwent tracheostomy. After logistic regression, 7 factors were determined as being independent perioperative risk factors for PMV. Discussion: Age ≥70 years old, left ventricular ejection fraction (LVEF ≤30%, preexisting respiratory or renal disease, emergency or re-do operation and use of preoperative inotropic agents are the main risk factors determined in this study on women undergoing CABG.

  16. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gunja, Ateka; Pandey, Yagya [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Xie, Hui [Division of Epidemiology and Biostatistics, University of Illinois at Chicago, Chicago, IL (United States); Faculty of Health Sciences, Simon Fraser University, Burnaby, BC (Canada); Wolska, Beata M. [Department of Physiology and Biophysics, Center for Cardiovascular Research, University of Illinois at Chicago, Chicago, IL (United States); Shroff, Adhir R.; Ardati, Amer K. [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States)

    2017-04-15

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm{sup 2}). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm{sup 2} ± 74.0 vs. 41.9 mGy cm{sup 2} ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image

  17. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Gunja, Ateka; Pandey, Yagya; Xie, Hui; Wolska, Beata M.; Shroff, Adhir R.; Ardati, Amer K.; Vidovich, Mladen I.

    2017-01-01

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm"2). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm"2 ± 74.0 vs. 41.9 mGy cm"2 ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise compared to

  18. Pleural subxyphoid drain confers better pulmonary function and clinical outcomes in chronic obstructive pulmonary disease after off-pump coronary artery bypass grafting: a randomized controlled trial.

    Science.gov (United States)

    Guizilini, Solange; Viceconte, Marcela; Esperança, Gabriel Tavares da M; Bolzan, Douglas W; Vidotto, Milena; Moreira, Rita Simone L; Câncio, Andréia Azevedo; Gomes, Walter J

    2014-01-01

    To evaluate the lung function and clinical outcome in severe chronic obstructive pulmonary disease in patients undergoing off-pump coronary artery bypass grafting with left internal thoracic artery graft, comparing the pleural drain insertion in the intercostal versus subxyphoid region. A randomized controlled trial. Chronic obstructive pulmonary disease patients were randomized into two groups according pleural drain site: II group (n=27) - pleural drain in intercostal space; SI group (n=29) - pleural drain in the subxyphoid region. Spirometry values (Forced Vital Capacity - and Forced expiratory volume in 1 second) were obtained on preoperative and 1, 3 and 5 postoperative days. Chest x-ray from preoperative until postoperative day 5 (POD5) was performed for monitoring respiratory events, such as atelectasis and pleural effusion. Pulmonary shunt fraction and pain score was evaluate preoperatively and on postoperative day 1. In both groups there was a significant decrease of the spirometry values (Forced Vital Capacity and Forced expiratory volume in 1 second) until POD5 (Ppleural drainage in severe Chronic obstructive pulmonary disease patients determined better preservation and recovery of pulmonary capacity and volumes with lower pulmonary shunt fraction and better clinical outcomes on early postoperative off-pump coronary artery bypass grafting.

  19. Local full-thickness skin graft of the donor arm--a novel technique for the reduction of donor site morbidity in radial forearm free flap.

    Science.gov (United States)

    Riecke, B; Assaf, A T; Heiland, M; Al-Dam, A; Gröbe, A; Blessmann, M; Wikner, J

    2015-08-01

    A novel technique to reduce donor site morbidity after radial forearm free flap (RFFF) harvest, using a local full-thickness skin graft (FTSG), is described. Thirty consecutive patients undergoing RFFF for head and neck reconstruction were enrolled in a prospective study. Donor site defect closure was performed with spindle-shaped FTSGs excised from the wavelike skin incision made for the vascular pedicle. Both the removal site of the FTSG on the volar forearm and the covered RFFF donor site healed uneventfully in 29 cases, with no impairment of function related to the skin graft. No skin graft failure and no exposure, tenting, or adherence of the flexor tendons occurred. All patients expressed satisfaction with postoperative pain, the functional outcome, and cosmetic appearance. Primary donor site defect closure could be achieved in all cases with the use of a local FTSG. This graft can be gained at the access incision for the vascular pedicle, avoids expansion of the incision for a local flap technique, and does not prolong wound healing, and thus reduces both donor site and graft site morbidity of the RFFF. This technique leads to an inconspicuous aesthetic result with no apparent relevant functional deficits and avoids the need for a second donor site. Copyright © 2015 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Nuclear DNA as Predictor of Acute Kidney Injury in Patients Undergoing Coronary Artery Bypass Graft: A Pilot Study.

    Science.gov (United States)

    Likhvantsev, Valery V; Landoni, Giovanni; Grebenchikov, Oleg A; Skripkin, Yuri V; Zabelina, Tatiana S; Zinovkina, Liudmila A; Prikhodko, Anastasia S; Lomivorotov, Vladimir V; Zinovkin, Roman A

    2017-12-01

    To measure the release of plasma nuclear deoxyribonucleic acid (DNA) and to assess the relationship between nuclear DNA level and acute kidney injury occurrence in patients undergoing cardiac surgery. Cardiovascular anesthesiology and intensive care unit of a large tertiary-care university hospital. Prospective observational study. Fifty adult patients undergoing cardiac surgery. Nuclear DNA concentration was measured in the plasma. The relationship between the level of nuclear DNA and the incidence of acute kidney injury after coronary artery bypass grafting was investigated. Cardiac surgery leads to significant increase in plasma nuclear DNA with peak levels 12 hours after surgery (median [interquartile range] 7.0 [9.6-22.5] µg/mL). No difference was observed between off-pump and on-pump surgical techniques. Nuclear DNA was the only predictor of acute kidney injury between baseline and early postoperative risk factors. The authors found an increase of nuclear DNA in the plasma of patients who had undergone coronary artery bypass grafting, with a peak after 12 hours and an association of nuclear DNA with postoperative acute kidney injury. Copyright © 2017 Elsevier Inc. All rights reserved.

  1. Acute Iliac Artery Rupture: Endovascular Treatment

    International Nuclear Information System (INIS)

    Chatziioannou, A.; Mourikis, D.; Katsimilis, J.; Skiadas, V.; Koutoulidis, V.; Katsenis, K.; Vlahos, L.

    2007-01-01

    The authors present 7 patients who suffered iliac artery rupture over a 2 year period. In 5 patients, the rupture was iatrogenic: 4 cases were secondary to balloon angioplasty for iliac artery stenosis and 1 occurred during coronary angioplasty. In the last 2 patients, the rupture was secondary to iliac artery mycotic aneurysm. Direct placement of a stent-graft was performed in all cases, which was dilated until extravasation was controlled. Placement of the stent-graft was successful in all the cases, without any complications. The techniques used, results, and mid-term follow-up are presented. In conclusion, endovascular placement of a stent-graft is a quick, minimally invasive, efficient, and safe method for emergency treatment of acute iliac artery rupture, with satisfactory short- and mid-term results

  2. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Zhonghua; Chaichana, Thanapong [Curtin University of Technology, Perth (Australia)

    2010-02-15

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair.

  3. Fenestrated Stent Graft Repair of Abdominal Aortic Aneurysm: Hemodynamic Analysis of the Effect of Fenestrated Stents on the Renal Arteries

    International Nuclear Information System (INIS)

    Sun, Zhonghua; Chaichana, Thanapong

    2010-01-01

    We wanted to investigate the hemodynamic effect of fenestrated stents on the renal arteries with using a fluid structure interaction method. Two representative patients who each had abdominal aortic aneurysm that was treated with fenestrated stent grafts were selected for the study. 3D realistic aorta models for the main artery branches and aneurysm were generated based on the multislice CT scans from two patients with different aortic geometries. The simulated fenestrated stents were designed and modelled based on the 3D intraluminal appearance, and these were placed inside the renal artery with an intra-aortic protrusion of 5.0-7.0 mm to reflect the actual patients' treatment. The stent wire thickness was simulated with a diameter of 0.4 mm and hemodynamic analysis was performed at different cardiac cycles. Our results showed that the effect of the fenestrated stent wires on the renal blood flow was minimal because the flow velocity was not significantly affected when compared to that calculated at pre-stent graft implantation, and this was despite the presence of recirculation patterns at the proximal part of the renal arteries. The wall pressure was found to be significantly decreased after fenestration, yet no significant change of the wall shear stress was noticed at post-fenestration, although the wall shear stress was shown to decrease slightly at the proximal aneurysm necks. Our analysis demonstrates that the hemodynamic effect of fenestrated renal stents on the renal arteries is insignificant. Further studies are needed to investigate the effect of different lengths of stent protrusion with variable stent thicknesses on the renal blood flow, and this is valuable for understanding the long-term outcomes of fenestrated repair

  4. Health-related quality of life following off-pump versus on-pump coronary artery bypass grafting in elderly moderate to high-risk patients

    DEFF Research Database (Denmark)

    Jensen, Birte Østergaard; Hughes, Pia; Rasmussen, Lars S

    2006-01-01

    Previous trials comparing coronary artery bypass grafting (CABG) with or without extracorporeal circulation have mainly enrolled selected patients at younger age and low risk. Patient-reported health-related quality of life has not been significantly different. We compared health-related quality...

  5. Influences of irradiation on the anastomotic sites of artificial graft

    International Nuclear Information System (INIS)

    Ogawa, Junichi; Inoue, Hiroshi; Koide, Shirosaku; Kawada, Shimei; Shotsu, Akira

    1989-01-01

    To examine the acute influences of irradiation on the anastomotic sites of EPTFE vascular grafts, experimental study was performed using canine dogs. After replacement of superior vena cava and bilateral femoral arteries with EPTFE grafts, a total of 20 to 100 Gy doses were given at the anastomotic sites of superior vena cava and right femoral artery. There were no degradation of grafts themselves or rupture in the anastomoses at cumulative anastomotic sites of superior vena cava, stenoses and/or overgrowth of granulation tissues were observed, although at those of right femoral artery, no remarkable differences were observed between dogs which received irradiation and those which did not receive. (author)

  6. Application of a pharmacokinetics-pharmacodynamics approach to the free propofol plasma levels during coronary artery bypass grafting surgery with hypothermic cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Carlos R. Silva-Filho

    2018-02-01

    Full Text Available OBJECTIVES: The objective of this study was to apply a pharmacokinetics-pharmacodynamics approach to investigate the free propofol plasma levels in patients undergoing coronary artery bypass grafting under hypothermic conditions compared with the off-pump procedure. METHODS: Nineteen patients scheduled for on-pump coronary artery bypass grafting under hypothermic conditions (n=10 or the equivalent off-pump surgery (n=9 were anesthetized with sufentanil and propofol target-controlled infusion (2 μg/mL during surgery. The propofol concentration was then reduced to 1 μg/mL, and a pharmacokinetics-pharmacodynamics analysis using the maximum-effect-sigmoid model obtained by plotting the bispectral index values against the free propofol plasma levels was performed. RESULTS: Significant increases (two- to five-fold in the free propofol plasma levels were observed in the patients subjected to coronary artery bypass grafting under hypothermic conditions. The pharmacokinetics of propofol varied according to the free drug levels in the hypothermic on-pump group versus the off-pump group. After hypothermic coronary artery bypass was initiated, the distribution volume increased, and the distribution half-life was prolonged. Propofol target-controlled infusion was discontinued when orotracheal extubation was indicated, and the time to patient extubation was significantly higher in the hypothermic on-pump group than in the off-pump group (459 versus 273 min, p=0.0048. CONCLUSIONS: The orotracheal intubation time was significantly longer in the hypothermic on-pump group than in the off-pump group. Additionally, residual hypnosis was identified through the pharmacokinetics-pharmacodynamics approach based on decreases in drug plasma protein binding in the hypothermic on-pump group, which could explain the increased hypnosis observed with this drug in this group of patients.

  7. Determination of the luminal diameter of the radial artery in man by high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1990-01-01

    measurements. By comparing the diameter of the reference object either filled with water or blood at 37 degrees C, the ultrasound velocity in human blood at 37 degrees C was calculated to be 1605 m/s. The intraobserver repeatability coefficients of in-vivo measurements of the radial artery in man were...... in the same range, whether measurements were repeated after 30 min (14%) or from day to day (12%). The interobserver repeatability coefficient was acceptable (15%) when the site of measurements was marked, whereas measurements without a mark resulted in a repeatability coefficient of 24%. The intravenous...

  8. Civilian popliteal artery injuries

    African Journals Online (AJOL)

    with reversed vein grafting in 68 patients, primary anastomosis in 33, prosthetic graft insertion in 11, ... patients underwent delayed amputation, giving an overall amputation rate of 37.5%. .... injury, level of arterial injury and type of repair had no significant ... patients, graft occlusion, and diseased crural vessels with poor run-.

  9. COVERED STENTS IN IATROGENIC CORONARY ARTERY FISTULA; A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Masoud Poormoghaddas

    2010-11-01

    Full Text Available Abstract    BACKGROUND: Coronary artery fistula is an abnormal communication between a coronary artery and a cardiac chamber or major cardiac vessels, mostly congenital but some of them are acquired as a consequence of coronary artery perforation.    CASE PRESENTATION: We report a case of cavity spilling coronary artery perforation during percutaneous coronary intervention 7 years ago. Because of continuing symptoms and risk of developing heart failure and pulmonary hypertension we were ought to treat this iatrogenically formed coronary artery fistula. We used stent graft implantation to treat it with acceptable results.    CONCLUSION: Beside their application as a rescue for acute coronary artery perforations, stent grafts can be used with acceptable results in iatrogenically acquired coronary artery coronary artery fistula      Keywords: Coronary artery perforation, Coronary artery fistula, Stent graft.

  10. Reconstruction of Traumatic External Iliac Artery Dissection Due to Vascular Clamping.

    Science.gov (United States)

    Kırnap, Mahir; Özçelik, Ümit; Akdur, Aydıncan; Ayvazoğlu Soy, Ebru H; Işıklar, İclal; Yarbuğ Karakayalı, Feza; Moray, Gökhan; Haberal, Mehmet

    2017-10-31

    Traumatic external iliac artery dissection after renal transplant is a rare complication, but it should be urgently managed due to its devastating effects on graft and lower limb circulation. External iliac artery dissection is seen more in recipients with diabetes mellitus and comorbid disease. Recipients with external iliac artery dissection should be treated immediately by percutaneus angioplasty or surgical reconstruction. In this study, we reported the management of 2 kidney transplant cases with external iliac artery dissection due to vascular clamping of the artery. External iliac artery dissection was diagnosed by ultrasonography in both cases. After failed percutaneous interventional angioplasty, we reconstructed the external iliac artery dissection surgically and replaced the external iliac artery with polytetra-fluoroethylene grafts in both patients. Both patients were discharged with normal functioning grafts showing 0.9 and 0.8 mg/dL serum creatinine levels at month 3 posttransplant. Close monitoring of recipients after transplant is mandatory for early diagnosis and early management of external iliac artery dissection to prevent graft loss and preserve lower limb circulation. Routine Doppler ultrasonography is an inexpensive and useful tool for early diagnosis in cases of sudden cessation or decrease in urine. In cases of failed percutaneous interventional angioplasty, reconstruction with synthetic vascular grafts can be safely applied in external iliac artery dissection.

  11. Effect of Ticagrelor Plus Aspirin, Ticagrelor Alone, or Aspirin Alone on Saphenous Vein Graft Patency 1 Year After Coronary Artery Bypass Grafting: A Randomized Clinical Trial.

    Science.gov (United States)

    Zhao, Qiang; Zhu, Yunpeng; Xu, Zhiyun; Cheng, Zhaoyun; Mei, Ju; Chen, Xin; Wang, Xiaowei

    2018-04-24

    The effect of ticagrelor with or without aspirin on saphenous vein graft patency in patients undergoing coronary artery bypass grafting (CABG) is unknown. To compare the effect of ticagrelor + aspirin or ticagrelor alone vs aspirin alone on saphenous vein graft patency 1 year after CABG. Randomized, multicenter, open-label, clinical trial among 6 tertiary hospitals in China. Eligible patients were aged 18 to 80 years with indications for elective CABG. Patients requiring urgent revascularization, concomitant cardiac surgery, dual antiplatelet or vitamin K antagonist therapy post-CABG, and who were at risk of serious bleeding were excluded. From July 2014 until November 2015, 1256 patients were identified and 500 were enrolled. Follow-up was completed in January 2017. Patients were randomized (1:1:1) to start ticagrelor (90 mg twice daily) + aspirin (100 mg once daily) (n = 168), ticagrelor (90 mg twice daily) (n = 166), or aspirin (100 mg once daily) (n = 166) within 24 hours post-CABG. Neither patients nor treating physicians were blinded to allocation. Primary outcome was saphenous vein graft patency 1 year after CABG (FitzGibbon grade A) adjudicated independently by a committee blinded to allocation. Saphenous vein graft patency was assessed by multislice computed tomographic angiography or coronary angiography. Among 500 randomized patients (mean age, 63.6 years; women, 91 [18.2%]), 461 (92.2%) completed the trial. Saphenous vein graft patency rates 1 year post-CABG were 88.7% (432 of 487 vein grafts) with ticagrelor + aspirin; 82.8% (404 of 488 vein grafts) with ticagrelor alone; and 76.5% (371 of 485 vein grafts) with aspirin alone. The difference between ticagrelor + aspirin vs aspirin alone was statistically significant (12.2% [95% CI, 5.2% to 19.2%]; P aspirin alone was not statistically significant (6.3% [95% CI, -1.1% to 13.7%]; P = .10). Five major bleeding episodes occurred during 1 year of follow-up (3 with

  12. Compliant electrospun silk fibroin tubes for small vessel bypass grafting.

    Science.gov (United States)

    Marelli, Benedetto; Alessandrino, Antonio; Farè, Silvia; Freddi, Giuliano; Mantovani, Diego; Tanzi, Maria Cristina

    2010-10-01

    Processing silk fibroin (SF) by electrospinning offers a very attractive opportunity for producing three-dimensional nanofibrillar matrices in tubular form, which may be useful for a biomimetic approach to small calibre vessel regeneration. Bypass grafting of small calibre vessels, with a diameter less than 6mm, is performed mainly using autografts, like the saphenous vein or internal mammary artery. At present no polymeric grafts made of SF are commercially available, mainly due to inadequate properties (low compliance and lack of endothelium cells). The aim of this work was to electrospin SF into tubular structures (Ø=6mm) for small calibre vessel grafting, characterize the morphological, chemico-physical and mechanical properties of the electrospun SF structures and to validate their potential to interact with cells. The morphological properties of electrospun SF nanofibres were investigated by scanning electron microscopy. Chemico-physical analyses revealed an increase in the crystallinity of the structure of SF nanofibres on methanol treatment. Mechanical tests, i.e. compliance and burst pressure measurements, of the electrospun SF tubes showed that the inner pressure to radial deformation ratio was linear for elongation up to 15% and pressure up to 400 mm Hg. The mean compliance value between 80 and 120 mm Hg was higher than the values reported for both Goretex(R) and Dacron(R) grafts and for bovine heterografts, but still slightly lower than those of saphenous and umbilical vein, which nowadays represent the gold standard for the replacement of small calibre arteries. The electrospun tubes resisted up to 575+/-17 mmHg, which is more than four times the upper physiological pressure of 120 mmHg and more than twice the pathological upper pressures (range 180-220 mmHg). The in vitro tests showed a good cytocompatibility of the electrospun SF tubes. Therefore, the electrospun SF tubes developed within this work represent a suitable candidate for small calibre

  13. Intraarterial 9-beta-methyl carbacyclin improves canine polytetrafluoroethylene graft patency

    International Nuclear Information System (INIS)

    Dacey, L.J.; Hees, P.S.; Cronenwett, J.L.

    1988-01-01

    This study examined the effect of 9-beta-methyl carbacyclin, a synthetic, stable prostacyclin analog, on canine polytetrafluoroethylene (PTFE) graft patency. Twenty-five dogs had 4 mm x 7 cm PTFE grafts implanted bilaterally into the femoral arteries. A subcutaneous infusion pump was used to deliver either saline solution (control) or 9-beta-methyl carbacyclin (Ciprostine) at 100 (CARB-100) or 200 ng/kg/min (CARB-200) through a femoral artery branch just proximal to one of the femoral grafts, with the contralateral graft serving as a noninfused control. Graft-platelet deposition (with 111 In-labeled platelets) was measured between the fifth and seventh days, with patency determined on the seventh day. Dogs were classified as aggregators (AGG [+]) if the preoperative epinephrine-enhanced sodium arachidonate platelet aggregation was greater than 20%. CARB-200 infusion significantly improved ipsilateral graft patency (80%) compared with noninfused grafts (50%, p less than 0.05), or grafts in control and CARB-100 dogs (43%, p less than 0.05). Anastomotic platelet deposition was decreased bilaterally in CARB-200 dogs by 45% to 59% compared with CARB-100 and control dogs (p less than 0.05). With the exception of grafts infused with CARB-200, AGG (+) dogs had significantly lower graft patency (26%) than nonaggregator AGG (-) dogs (71%, p less than 0.01). CARB-200 infusion significantly improved graft patency in AGG (+) dogs (71%), compared with control and CARB-100-infused grafts (19%, p less than 0.025). Intra-arterial 9-beta-methyl carbacyclin improved early PTFE graft patency and inhibited platelet deposition in a severe canine model, independent of baseline platelet aggregation status, which also had an important effect on graft patency

  14. Successful percutaneous stenting of a right gastroepiploic coronary bypass graft using monorail delivery system: a case report.

    Science.gov (United States)

    Alam, M; Safi, A M; Mandawat, M K; Anderson, J E; Kwan, T; Feit, A; Clark, L T

    2000-02-01

    The right gastroepiploic artery (RGEA) is being successfully used as an arterial conduit in a selected group of patients undergoing coronary artery bypass graft surgery. However, myocardial ischemia may result due to spasm, occlusion, and stenosis of this graft. The anastamosis site at distal right coronary artery (RCA) or posterior descending artery (PDA) is the most common location for stenosis of an in situ gastroepiploic coronary bypass graft. Balloon angioplasty of such stenoses has been reported with optimal short-term results. Stent deployment would decrease the restenosis rate, so that repeat procedures could be minimized for these technically challenging lesions. We describe a case of successful deployment of a stent with monorail delivery system at the anastamotic site stenosis of an in situ gastroepiploic right coronary artery bypass graft. This percutaneous coronary intervention could prevent redo coronary artery bypass graft surgery. Cathet. Cardiovasc. Intervent. 49:197-199, 2000. Copyright 2000 Wiley-Liss, Inc.

  15. The mechanical properties of infrainguinal vascular bypass grafts: their role in influencing patency.

    Science.gov (United States)

    Sarkar, S; Salacinski, H J; Hamilton, G; Seifalian, A M

    2006-06-01

    When autologous vein is unavailable, prosthetic graft materials, particularly expanded polytetrafluoroethylene are used for peripheral arterial revascularisation. Poor long term patency of prosthetic materials is due to distal anastomotic intimal hyperplasia. Intimal hyperplasia is directly linked to shear stress abnormalities at the vessel wall. Compliance and calibre mismatch between native vessel and graft, as well as anastomotic line stress concentration contribute towards unnatural wall shear stress. High porosity reduces graft compliance by causing fibrovascular infiltration, whereas low porosity discourages the development of an endothelial lining and hence effective antithrombogenicity. Therefore, consideration of mechanical properties is necessary in graft development. Current research into synthetic vascular grafts concentrates on simulating the mechanical properties of native arteries and tissue engineering aims to construct a new biological arterial conduit.

  16. Outcomes of coronary artery bypass grafting versus percutaneous coronary intervention with drug-eluting stents for patients with multivessel coronary artery disease.

    Science.gov (United States)

    Javaid, Aamir; Steinberg, Daniel H; Buch, Ashesh N; Corso, Paul J; Boyce, Steven W; Pinto Slottow, Tina L; Roy, Probal K; Hill, Peter; Okabe, Teruo; Torguson, Rebecca; Smith, Kimberly A; Xue, Zhenyi; Gevorkian, Natalie; Suddath, William O; Kent, Kenneth M; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2007-09-11

    Advances in coronary artery bypass grafting (CABG) surgery and percutaneous coronary intervention (PCI) with drug-eluting stents have dramatically improved results of these procedures. The optimal treatment for patients with multivessel coronary artery disease is uncertain given the lack of prospective, randomized data reflecting current practice. This study represents a "real-world" evaluation of current technology in the treatment of multivessel coronary artery disease. A total of 1680 patients undergoing revascularization for multivessel coronary artery disease were identified. Of these, 1080 patients were treated for 2-vessel disease (196 CABG and 884 PCI) and 600 for 3-vessel disease (505 CABG and 95 PCI). One-year mortality, cerebrovascular events, Q-wave myocardial infarction, target vessel failure, and composite major adverse cardiovascular and cerebrovascular events were compared between the CABG and PCI cohorts. Outcomes were adjusted for baseline covariates and reported as hazard ratios. The unadjusted major adverse cardiovascular and cerebrovascular event rate was reduced with CABG for patients with 2-vessel disease (9.7% CABG versus 21.2% PCI; P<0.001) and 3-vessel disease (10.8% CABG versus 28.4% PCI; P<0.001). Adjusted outcomes showed increased major adverse cardiovascular and cerebrovascular event with PCI for patients with 2-vessel (hazard ratio 2.29; 95% CI 1.39 to 3.76; P=0.01) and 3-vessel disease (hazard ratio 2.90; 95% CI 1.76 to 4.78; P<0.001). Adjusted outcomes for the nondiabetic subpopulation demonstrated equivalent major adverse cardiovascular and cerebrovascular event with PCI for 2-vessel (hazard ratio 1.77; 95% CI 0.96 to 3.25; P=0.07) and 3-vessel disease (hazard ratio 1.70; 95% CI 0.77 to 3.61; P=0.19). Compared with PCI with drug-eluting stents, CABG resulted in improved major adverse cardiovascular and cerebrovascular event in patients with 2- and 3-vessel coronary artery disease, primarily in those with underlying diabetes

  17. A coincidental variation of the axillary artery: the brachioradial artery and the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Marek Konarik

    2014-09-01

    Full Text Available A case of anomalous terminal branching of the axillary artery was encountered and described in a left upper limb of a male cadaver. A series of 214 upper limbs of Caucasian race was dissected. A variant artery, stemming from the very end of the axillary artery followed a superficial course distally. It passed the cubital fossa, ran on the lateral side of the forearm as usual radial artery, crossed ventrally to the palm and terminated in the deep palmar arch. This vessel is a case of the brachioradial artery (incorrectly termed as the “radial artery with high origin”. Moreover, it was associated with another variation, concerning the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle. The anatomical knowledge of the axillary region is essential for radiodiagnostic, surgical and traumatologic procedures. The superficially located artery brings an elevated danger of heavy bleeding in all unexpected situations, its variant branching can cause problems in radial catheterization procedures and the anomalously coursing other arterial variant poses an elevated danger in surgical procedures concerning the surgical neck of humerus.

  18. Alterations in plasma soluble vascular endothelial growth factor receptor-1 (sFlt-1 concentrations during coronary artery bypass graft surgery: relationships with post-operative complications

    Directory of Open Access Journals (Sweden)

    Orsel Isabelle

    2008-04-01

    Full Text Available Abstract Background Plasma concentrations of sFlt-1, the soluble form of the vascular endothelial growth factor receptor (VEGF, markedly increase during coronary artery bypass graft (CABG surgery with extracorporeal circulation (ECC. We investigated if plasma sFlt-1 values might be related to the occurrence of surgical complications after CABG. Methods Plasma samples were collected from the radial artery catheter before vascular cannulation and after opening the chest, at the end of ECC just before clamp release, after cross release, after weaning from ECC, at the 6th and 24th post-operative hour. Thirty one patients were investigated. The presence of cardiovascular, haematological and respiratory dysfunctions was prospectively assessed. Plasma sFlt-1 levels were measured with commercially ELISA kits. Results Among the 31 investigated patients, 15 had uneventful surgery. Patients with and without complications had similar pre-operative plasma sFlt-1 levels. Lowered plasma sFlt-1 levels were observed at the end of ECC in patients with haematological (p = 0.001, ANOVA or cardiovascular (p = 0.006 impairments, but not with respiratory ones (p = 0.053, as compared to patients with uneventful surgery. Conclusion These results identify an association between specific post-CABG complication and the lower release of sFlt-1 during ECC. sFlt-1-induced VEGF neutralisation might, thus, be beneficial to reduce the development of post-operative adverse effects after CABG.

  19. Endovascular Placement of an Extraluminal Femoropopliteal Bypass Graft in Human Cadavers

    International Nuclear Information System (INIS)

    Maynar, Manuel; Llorens, Rafael; Lopez-Sanchez, Carmen; Garcia-Martinez, Virginio; Qian Zhong; Lopera, Jorge; Castaneda, Wilfrido R.

    2005-01-01

    Purpose. A method to create an extraluminal femoropopliteal bypass graft using endovascular techniques was evaluated in situ on cadaver extremities in an attempt to develop a minimally invasive alternative technique for the management of infrainguinal occlusive arterial disease. Methods. The endovascular placement of an extraluminal femoropopliteal bypass graft was undertaken in 5 cadaver legs. Following percutaneous access to the popliteal artery (PA) or common femoral artery (CFA), a Rosch-Uchida needle was used to perforate the vascular wall, followed by the creation of an extraluminal tract using a looped wire and catheter. Once the desired level was reached the needle was again used to perforate the vascular wall of the proximal superficial femoral artery (SFA) or PA depending on the access used. Self-expanding expanded polytetrafluoroethylene (ePTFE) stent-grafts were then deployed to establish the extraluminal femoropopliteal bypass connecting the two arterial puncture sites. Following dilatation of the stent-graft, angiography was performed to assess the endoprostheses and to look for contrast leaks. Results. Technical success was achieved in all 5 legs. Procedure time varied from 15 to 30 min. The angiographic studies performed immediately after completion of the bypass procedure showed patency of the grafts with no evidence of kinking or leakage in any of the cases. Conclusion. This study has proved that the endovascular placement of an extraluminal femoropopliteal bypass graft in human cadaver legs using endovascular techniques under fluoroscopic control is technically feasible

  20. Coronary artery bypass grafting in a patient with protein S deficiency: Perioperative implications

    Directory of Open Access Journals (Sweden)

    Baskaran Balan

    2014-01-01

    Full Text Available Protein S (PS along with activated protein C plays an important role in the down-regulation of in vivo thrombin generation. Its deficiency can cause abnormal and inappropriate clot formation within the circulation necessitating chronic anticoagulation therapy. The risk of developing thrombotic complications is heightened in the perioperative period in patients undergoing cardiac surgery with cardiopulmonary bypass (CPB. Heparin resistance is very rare in these patients, especially when antithrombin levels are near normal. Management of CPB in this scenario is quite challenging. We report the perioperative management, particularly the CPB management, of a patient with type I PS deficiency and incidentally detected heparin resistance, who underwent coronary artery bypass grafting with CPB.

  1. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    International Nuclear Information System (INIS)

    Moore, R.K.G.; Sampson, C.; MacDonald, S.; Moynahan, C.; Groves, D.; Chester, M.R.

    2005-01-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor

  2. Coronary artery bypass graft imaging using ECG-gated multislice computed tomography: Comparison with catheter angiography

    Energy Technology Data Exchange (ETDEWEB)

    Moore, R.K.G. [Cardiothoracic Centre, Liverpool (United Kingdom)]. E-mail: moore@roger.go-legend.net; Sampson, C. [Cardiothoracic Centre, Liverpool (United Kingdom); MacDonald, S. [Cardiothoracic Centre, Liverpool (United Kingdom); Moynahan, C. [Cardiothoracic Centre, Liverpool (United Kingdom); Groves, D. [National Refractory Angina Centre, Liverpool (United Kingdom); Chester, M.R. [National Refractory Angina Centre, Liverpool (United Kingdom)

    2005-09-01

    AIM: To compare the value of multislice computerized tomography (MSCT) in imaging coronary artery bypass grafts (CABGs) by direct quantitative comparison with standard invasive angiography. METHODS: Using MSCT, 50 consecutive patients who had previously undergone CABG surgery and had recently undergone invasive angiography for recurrent angina pectoris, were studied further using MSCT after intravenous injection of non-ionic contrast agent; cardiac imaging was performed during a single breath-hold. Graft anatomy was quantified, using both quantitative coronary angiography (QCA) and MSCT, by different investigators blinded to each other. Reproducibility was quantified using the standard error of the measurement expressed as a percentage in log-transformed values (CV%) and intraclass correlation (ICC). RESULTS: All 150 grafts were imaged using MSCT; only 4 patent grafts were not imaged using selective angiography. Good agreement was achieved between MSCT and QCA on assessment of proximal anastomoses (CV% 25.2, ICC 0.84), mid-vessel luminal diameter (CV% 15.5, ICC 0.91) and aneurysmal dilations (CV% 14.3). Reasonable agreement was reached on assessment of distal anastomoses (CV% 26.7, ICC 0.66) and categorization of distal run-off (ICC 0.73). Good agreement was observed for stenoses of over 50% luminal loss (CV% 8.7, ICC 0.97) but agreement on assessment of less severe lesions was poor (CV% 208.7, ICC 0.51). CONCLUSION: This study demonstrates that CABGs can be quantitatively evaluated using MSCT, and that significant lesions present in all CABG segments can be reliably identified. Agreement between MSCT and QCA for lesions of less than 50% luminal loss was poor.

  3. Management of carotid Dacron patch infection: a case report using median sternotomy for proximal common carotid artery control and in situ polytetrafluoroethylene grafting.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Ceccanei, Gianluca; Pacilè, Maria Antonietta

    2009-01-01

    We report on a 58-year-old male who presented with an enlarging cervical hematoma 3 months following carotid endarterectomy with Dacron patch repair, due to septic disruption of the Dacron patch secondary to presumed infection. The essential features of this case are the control of the proximal common carotid artery gained through a median sternotomy, because the patient was markedly obese with minimal thyromental distance, and the treatment consisting of in situ polytetrafluoroethylene bypass grafting, due to the absence of a suitable autogenous saphenous vein. Median sternotomy is rarely required in case of reintervention for septic false aneurysms and hematomas following carotid endarterectomy but should be considered whenever difficult control of the common carotid artery, when entering the previous cervicotomy, is anticipated. In situ polytetrafluoroethylene grafting can be considered if autogenous vein material is lacking.

  4. [Arthroscopy-guided core decompression and bone grafting combined with selective arterial infusion for treatment of early stage avascular necrosis of femoral head].

    Science.gov (United States)

    Guo, Hao-Shan; Tian, Yi-Jun; Liu, Gang; An, Long; Zhou, Zhan-Guo; Liu, Huan-Zhen

    2018-01-25

    To observe the clinical effects of arthroscopy-guided core decompression and bone grafting combined with selective arterial infusion for early stage avascular necrosis of femoral head. From January 2010 to December 2014, 76 patients(76 hips) diagnosed as Ficat II stage avascular necrosis of femoral head were randomly divided into experimental group and control group. In the experimental group, there were 27 males and 8 females aged from 24 to 55 years old with an average of (43.96±6.81) years, treated with arthroscopic-guided core decompression and bone grafting combined with selective arterial infusion. Along the direction of the femoral neck, an 8 mm-diameter tunnel to necrotic areas was drilled, then curettage of necrotic bone was performed under arthroscope, and the iliac bone was grafted. In the control group, there were 29 males and 12 females aged from 26 to 56 years old with an average of (44.62±7.33) years, treated with percutaneous core decompression combined with selective arterial infusion. The preoperative and postoperative Harris scores were recorded and the changes of X-rays were analyzed. All the patients were followed up with an average of 30 months. Postoperative follow-up at 12 months showed that there was significant difference in imaging outcome between two groups( P 0.05), but there was significant difference in postoperative Harris score( P necrosis are effective. Using arthroscopic-guided core decompression method, the necrotic bone can be positioned and scraped more accurately, and can obtain better results. Copyright© 2018 by the China Journal of Orthopaedics and Traumatology Press.

  5. A Limb-Threatening Long Arterial Dissection Caused by Humerus Neck Fracture: A Case Report

    Directory of Open Access Journals (Sweden)

    Kurnaz R

    2018-03-01

    Full Text Available Proximal humerus fracture is a common arm trauma and rarely occurs with vascular injury which however is a serious complication. In this case report, we present a long segment dissection of the axillary and brachial arteries as a rare complication due to fragmented proximal humerus fracture and shoulder dislocation. An 80-year old female patient was seen at the emergency department. Radiograph examination has revealed a fragmented proximal humerus fracture besides dislocation of the head of humerus towards the axillary area. On vascular examination, acute arterial occlusion such as absence of radial and ulnar pulses were observed in her left hand. The patient was immediately taken to the operating room. The dissection included the entire segment approximately 20cm between the distal subclavian artery and the distal brachial artery. This injured segment was removed and a 6mm Polytetrafluroethylene (PTFE graft with rings was interpositoned between subclavian and brachial arteries. This case is a rarity because of such a significant complication after a small injury. Axillary artery injuries caused by humeral neck fractures are rare but should not be missed by the physician.

  6. A case report and brief review of the literature on bilateral retinal infarction following cardiopulmonary bypass for coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    Trethowan Brian A

    2011-11-01

    Full Text Available Abstract Postoperative visual loss is a devastating perioperative complication. The commonest aetiologies are anterior ischaemic optic neuropathy (AION, posterior ischaemic optic neuropathy (PION, and central retinal artery occlusion (CRAO. These appear to be related to certain types of operation, most commonly spinal and cardiac bypass procedures; with the rest divided between: major trauma causing excessive blood loss; head/neck and nasal or sinus surgery; major vascular procedures (aortic aneurysm repair, aorto-bifemoral bypass; general surgery; urology; gynaecology; liposuction; liver transplantation and duration of surgery. The non-surgical risk factors are multifactorial: advanced age, prolonged postoperative anaemia, positioning (supine v prone, alteration of venous drainage of the retina, hypertension, smoking, atherosclerosis, hyperlipidaemia, diabetes, hypercoagulability, hypotension, blood loss and large volume resuscitation. Other important cardiac causes are septic emboli from bacterial endocarditis and emboli caused by atrial myxomata. The majority of AION cases occur during CPB followed by head/neck surgery and prone spine surgery. CPB is used to allow coronary artery bypass grafting on a motionless heart. It has many side-effects and complications associated with its use and we report here a case of bilateral retinal infarction during routine coronary artery bypass grafting in a young male patient with multiple risk factors for developing this complication despite steps to minimise its occurrence.

  7. Treatment of a Left Internal Mammary Artery to Pulmonary Artery Fistula with Polytetrafluoroethylene Covered Stents: A Case Report and Review of the Literature

    International Nuclear Information System (INIS)

    Abbott, J. Dawn; Brennan, Joseph J.; Remetz, Michael S.

    2004-01-01

    Internal mammary artery (IMA) to pulmonary artery (PA) fistula is a rare complication of coronary artery bypass grafting (CABG) that may present as myocardial ischemia. We describe a case of left IMA-to-PA fistula treated with balloon expandable coronary polytetrafluoroethylene (PTFE) graft stents and review previously reported cases of this entity

  8. The use of the inferior epigastric artery for accessory lower polar artery revascularization in live donor renal transplantation.

    Science.gov (United States)

    El-Sherbiny, M; Abou-Elela, A; Morsy, A; Salah, M; Foda, A

    2008-01-01

    This study describes the surgical technique and outcomes of live donor renal allografts with multiple arteries in which the lower polar artery was anastomosed to the inferior epigastric artery after declamping. Between 1988 and 2004, 477 consecutive live donor renal transplants were performed, including 429 with single and 48 with multiple arteries. Anastomosis of the lower polar artery to the inferior epigastric artery was used for 15 grafts with multiple arteries. Successful revascularization of all areas of the transplanted graft was confirmed by Doppler ultrasonography in most patients and radionuclide renal scanning +/- MRA in some patients. In live donor renal transplantation with multiple arteries, the anastomosis of the lower polar artery to the inferior epigastric artery after declamping avoids prolongation of the ischemia time that occurs with other surgical and microsurgical techniques of intracorporeal and ex vivo surgeries.

  9. Clinical characteristics and usage of statins in patients with stable ischemic heart disease referred for angiography or coronary artery bypass grafting

    Directory of Open Access Journals (Sweden)

    I.V. Shklianka

    2017-12-01

    Full Text Available The aim – to compare the clinical characteristics and frequency of statins usage in real clinical practice in patients referred to a specialized clinic for angiography or coronary artery bypass grafting. Materials and methods. In a retrospective slice single-center study data from a primary examination of 155 patients with stable ischemic heart disease, consecutively selected for coronary artery bypass grafting surgery, were analyzed. Depending on the inclusion of statins in the list of medicinal prescriptions, patients were retrospectively divided into two groups: those who had been prescribed statins while they were initially referred to a specialized cardiac surgery center for angiography or revascularization (n = 84 and those who were not prescribed statins (n ​​= 71. Results. The studied patients’ cohort was characterized by earlier coronary events, signs of the peripheral artery atherosclerosis and other absolute indications for treatment with statins in vast majority of cases. At the same time, groups of patients who had been and had not been prescribed statins, did not differ by vast majority of demographic, clinical and instrumental characteristics, concomitant diseases and risk factors. No statin therapy was associated with higher levels of total cholesterol and interleukin-6 compared with the group of patients taking statins (total cholesterol, respectively, 4.8 versus 4.2 mmol/l (p = 0.016 and interleukin-6, respectively, 4.4 versus. 3.1 p/ml (p = 0.022. In general, statins were prescribed in 54,2 % of patients, among them high doses – in 17 patients (20.2 %, moderate – 46 patients (54.8 %, low – 21 patients (25 %. Conclusions. The obtained data show the insufficient level of ambulatory statins usage in patients with ischemic heart disease referred for myocardial revascularization and significant discrepancy between clinical characteristics and real statins usage. Therefore, there is a great need to determine the

  10. Endovascular treatment with a stent-graft for internal carotid artery laceration during trans sphenoidal surgery: a case report

    International Nuclear Information System (INIS)

    Choe, Eun Hwa; Ko, Ji Ho; Lee, Tae Hong; Rho, Myung Ho

    2008-01-01

    An internal carotid artery (ICA) tear during or after trans-sphenoidal surgery (TSS) is rare but may cause potentially lethal complications. A 23-year-old female patient visited our hospital for treatment of a Rathke's cleft cyst. The patient had massive hemorrhage during surgery and angiography performed after surgery showed laceration of the cavernous ICA. We successfully controlled the hemorrhage with emergency placement of an endovascular stent-graft

  11. Hepatorenal bypass using autogenous, free internal iliac artery graft: An attractive alternative to revascularize the right kidney in Takayasu's disease.

    Science.gov (United States)

    Khattar, Nikhil; Guleria, Sandeep; Sharma, Sanjeev

    2012-04-01

    Nonspecific aortoarteritis or Takayasu's disease (TD) is a chronic pan endarteritis of unknown origin involving the aorta and its major branches affecting young adults especially women. The disease is more common in eastern Asian countries. Hypertension in these patients generally reflects as renal artery stenosis, which is seen in 28-75% of patients. Surgical revascularization is occasionally needed in patients with failed medical management or endovascular interventions. We report two cases of Takayasu's arteritis in young women where renal revascularization was done using free internal iliac artery hepatorenal bypass graft with excellent control of hypertension in the postoperative period.

  12. [Evaluation and Optimization of Microvascular Arterial Anastomoses by Transit Time Flow Measurement].

    Science.gov (United States)

    Herberhold, S; Röttker, J; Bartmann, D; Solbach, A; Keiner, S; Welz, A; Bootz, F; Laffers, W

    2016-03-01

    INDRODUCTION: The regular application of transit time flow measurement in microvascular anastomoses during heart surgery has lead to improvements of the outcome of coronary artery bypass grafts. Our study was meant to discover whether this measurement method was also applicable for evaluation and optimization of microvascular arterial anastomoses of radial forearm flaps. In this prospective examination a combining ultrasound imaging and transit time flow measurement device (VeriQ, MediStim) was used during surgery to assess anastomotic quality of 15 radial forearm flaps. Pulsatility index (PI) and mean blood flow were measured immediately after opening the arterial anastomosis as well as 15 min afterwards. Furthermore, application time and description of handling were recorded seperately for every assessment. Mean blood flow immediately after opening the anastomosis and 15 min later were 3.9 and 3.4 ml/min resepectively showing no statistically significant difference (p=0.96). There was no significance in the increase of pulsatility index from 22.1 to 27.2 (p=0.09) during the same time range, either. Due to measurement results showing atypical pulse curves in 2 cases decision for surgical revision of the anastomoses was made. All forearm flaps showed good vascularisation during follow-up. Time for device set up, probe placement and measurements was about 20 min. Handling was described to be uncomplicated without exception. There were no noteworthy problems. Transit time flow measurement contributes to the improvement of anastomotic quality and therefore to the overall outcome of radial forearm flaps. The examined measurement method provides objective results and is useful for documentation purposes. © Georg Thieme Verlag KG Stuttgart · New York.

  13. SheppHeartCABG trial-comprehensive early rehabilitation after coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Hojskov, Ida Elisabeth; Moons, Philip; Hansen, Niels Viggo

    2017-01-01

    rehabilitation. The SheppHeartCABG trial will investigate the effect of early comprehensive rehabilitation in early phase rehabilitation versus usual care. The aim of this paper is to present the protocol for the SheppHeartCABG trial. METHODS/ANALYSIS: SheppHeartCABG is an investigator-initiated randomised...... clinical superiority trial with blinded outcome assessment, employing 1:1 central randomisation to rehabilitation plus usual care versus usual care alone. On the basis of a sample size calculation, 326 patients undergoing coronary artery bypass grafting will be included from two clinical sites. All...... patients receive usual care and patients allocated to the experimental intervention follow 4 weeks rehabilitation consisting of an exercise programme, psycho-educative consultations and a compact mindfulness programme. The primary outcome is physical function measured by the 6-min walk test. The secondary...

  14. Blood-conservation techniques for coronary-artery bypass surgery at a private hospital.

    Science.gov (United States)

    Davies, M J; Picken, J; Buxton, B F; Fuller, J A

    1988-11-21

    The utilization of homologous blood and blood products was recorded in 100 consecutive patients who underwent primary coronary-artery bypass surgery. Nine patients underwent saphenous-vein grafts only, 55 patients underwent a single internal-mammary-artery graft that was supplemented by vein grafts and 36 patients underwent bilateral internal-mammary-artery grafts and vein grafts. All patients underwent normovolaemic haemodilution, and autologous blood was collected before bypass surgery. Residual blood was collected from the cardiopulmonary bypass machine and was washed and concentrated in a cell processor, and blood also was scavenged postoperatively from the mediastinal drainage tubes as methods to conserve blood. The mean (+/- SD) utilization of homologous blood was 1.3 +/- 1.5 units with 0.2 +/- 0.7 units of fresh-frozen plasma being used, and 0.8 +/- 2.1 units of platelets being used. The utilization of homologous blood was not different among the three different methods of coronary-artery bypass surgery, but patients who underwent bilateral internal-mammary-artery grafts suffered a greater postoperative loss of blood than did those patients who underwent saphenous-vein grafts or single internal-mammary-artery grafts. A comparison of patients who were taking aspirin or a non-steroidal anti-inflammatory drug preoperatively with those patients who were not showed no difference in the utilization of homologous blood but a statistically-significant difference was found in the loss of blood postoperatively.

  15. Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    Science.gov (United States)

    Fyrdahl, Alexander; Vargas Paris, Roberto; Nyrén, Sven; Holst, Karen; Ugander, Martin; Lindholm, Peter; Sigfridsson, Andreas

    2018-03-14

    To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were imaged at 1.5 T using a Cartesian and golden-angle radial 2D balanced SSFP pulse sequence. The acquisitions were made under free breathing without contrast agent enhancement. The radial acquisitions were reconstructed at 3 temporal footprints. All series were scored from 1 to 5 for perceived diagnostic quality, artifact level, and vessel sharpness in multiple anatomical locations. In addition, vessel sharpness and blood-to-blood clot contrast were measured. Quantitative measurements showed higher vessel sharpness for golden-angle radial (n = 76, 0.79 ± 0.11 versus 0.71 ± 0.16, p golden-angle radial in the 2 patients. At comparable temporal footprints, golden-angle radial was scored higher for diagnostic quality (mean ± SD, 2.3 ± 0.7 versus 2.2 ± 0.6, p < .01) and vessel sharpness (2.2 ± 0.8 versus 2.1 ± 0.5, p < .01), whereas the artifact level did not differ (3.0 ± 0.9 versus 3.0 ± 1.0, p = .80). The ability to retrospectively choose a temporal resolution and perform sliding-window reconstructions was demonstrated in patients. In pulmonary artery imaging, the motion and flow robustness of a radial trajectory does both improve image quality over Cartesian trajectory in healthy volunteers, and allows for flexible selection of temporal footprints and the ability to perform real-time sliding window reconstructions, which could potentially provide further diagnostic insight. © 2018 International Society for Magnetic Resonance in Medicine.

  16. Patient Specific Multiscale Simulations of Blood Flow in Coronary Artery Bypass Surgery

    Science.gov (United States)

    Bangalore Ramachandra, Abhay; Sankaran, Sethuraman; Kahn, Andrew M.; Marsden, Alison L.

    2013-11-01

    Coronary artery bypass surgery is performed to revascularize blocked coronary arteries in roughly 400,000 patients per year in the US.While arterial grafts offer superior patency, vein grafts are used in more than 70% of procedures, as most patients require multiple grafts. Vein graft failure (approx. 50% within 10 years) remains a major clinical issue. Mounting evidence suggests that hemodynamics plays a key role as a mechano-biological stimulus contributing to graft failure. However, quantifying relevant hemodynamic quantities (e.g. wall shear stress) invivo is not possible directly using clinical imaging techniques. We numerically compute graft hemodynamics in a cohort of 3-D patient specific models using a stabilized finite element method. The 3D flow domain is coupled to a 0D lumped parameter circulatory model. Boundary conditions are tuned to match patient specific blood pressures, stroke volumes & heart rates. Results reproduce clinically observed coronary flow waveforms. We quantify differences in multiple hemodynamic quantities between arterial & venous grafts & discuss possible correlations between graft hemodynamics & clinically observed graft failure.Such correlations will provide further insight into mechanisms of graft failure and may lead to improved clinical outcomes.

  17. Effect of different dosages of nitroglycerin infusion on arterial blood gas tensions in patients undergoing on- pump coronary artery bypass graft surgery.

    Science.gov (United States)

    Masoumi, Gholamreza; Pour, Evaz Hidar; Sadeghpour, Ali; Ziayeefard, Mohsen; Alavi, Mostapha; Anbardan, Sanam Javid; Shirani, Shahin

    2012-02-01

    On-pump coronary artery bypass graft (CABG) surgery impairs gas exchange in the early postoperative period. The main object on this study was evaluation of changes in arterial blood gas values in patients underwent on pump CABG surgery receiving different dose of intravenous nitroglycerin (NTG). sixty-seven consecutive patients undergoing elective on-pump CABG randomly enrolled into three groups receiving NTG 50 μg/min (Group N1, n =67), 100 μg/min (Group N2, n = 67), and 150 μg/min (Group N3, n = 67). Arterial blood gas (ABG) tensions were evaluated just before induction of anesthesia, during anesthesia, at the end of warming up period, and 6 h after admission to the intensive care unit. Pao2 and PH had the highest value during surgery in Group N1, Group N2, and Group N3. No significant difference was noted in mean values of Pao2 and PH during surgery between three groups (P > 0.05). There was no significant difference in HCO3 values in different time intervals among three groups (P > 0.05). our results showed that infusing three different dosage of NTG (50, 100, and 150 μg/min) had no significant effect on ABG tensions in patients underwent on-pump CABG surgery.

  18. Sternal Healing after Coronary Artery Bypass Grafting Using Bilateral Internal Thoracic Arteries: Assessment by Computed Tomography Scan

    Directory of Open Access Journals (Sweden)

    Yoon Cheol Shin

    2015-02-01

    Full Text Available Background: This study aimed to investigate sternal healing over time and the incidence of poor sternal healing in patients undergoing coronary artery bypass graft (CABG surgery using bilateral internal thoracic arteries. Methods: This study enrolled 197 patients who underwent isolated CABG using skeletonized bilateral internal thoracic arteries (sBITA from 2006 through 2009. Postoperative computed tomography (CT angiography was performed on all patients at monthly intervals for three to six months after surgery. In 108 patients, an additional CT study was performed 24 to 48 months after surgery. The axial CT images were used to score sternal fusion at the manubrium, the upper sternum, and the lower sternum. These scores were added to evaluate overall healing: a score of 0 to 1 reflected poor healing, a score of 2 to 4 was defined as fair healing, and a score of 5 to 6 indicated complete healing. Medical records were also retrospectively reviewed to identify perioperative variables associated with poor early sternal healing. Results: Three to six months after surgery, the average total score of sternal healing was 2.07±1.52 and 68 patients (34.5% showed poor healing. Poor healing was most frequently found in the manubrium, which was scored as zero in 72.6% of patients. In multivariate analysis, the factors associated with poor early healing were shorter post-surgery time, older age, diabetes mellitus, and postoperative renal dysfunction. In later CT images, the average sternal healing score improved to 5.88±0.38 and complete healing was observed in 98.2% of patients. Conclusion: Complete sternal healing takes more than three months after a median sternotomy for CABG using sBITA. Healing is most delayed in the manubrium.

  19. Influence of pleural drain insertion in lung function of patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Ozelami Vieira, Irinea Beatriz Carvalho; Vieira, Fabiano F; Abrão, João; Gastaldi, Ada Clarice

    2012-01-01

    Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (ppleural drain location on breathing. PaO(2) on the second PO increased significantly in SX group compared with IC group (pDrain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters. Copyright © 2012 Elsevier Editora Ltda. All rights reserved.

  20. Morphological and functional consequences of transradial coronary angiography on the radial artery: implications for its use as a bypass conduit.

    Science.gov (United States)

    Gaudino, Mario; Leone, Alessandro; Lupascu, Andrea; Toesca, Amelia; Mazza, Andrea; Ponziani, Francesca Romana; Flore, Roberto; Tondi, Paolo; Massetti, Massimo

    2015-09-01

    To assess the degree of damage to the radial artery (RA) in coronary artery bypass grafting (CABG) patients who underwent preoperative transradial coronary angiography (RA-CA). From May 2012 to October 2013, 50 consecutive CABG patients who underwent RA-CA were prospectively enrolled in the study. All patients underwent echo-Doppler evaluation of the RA of the catheterized arm; the contralateral RA was used as control. The distal segment of the RA was submitted to immunohistochemical assessment of endothelial integrity. Patients were divided in three groups according to the time interval from angiography to evaluation: ≤24 h, >24 h to <7 days and ≥7 days. Baseline RA median diameters were 0.25 ± 0.04 cm in the cannulated arm and 0.22 ± 0.04 cm in the non-cannulated arm (P = 0.01). The flow-mediated dilatation (FMD) in the RA in the catheterized arm and in the control arm were 11.6 ± 7.9 and 14.2 ± 8.9 (P = 0.01), respectively. A statistically significant correlation was found between FMD of the catheterized RA and the time from RA-CA (Pearson's r = 0.348). Linear regression analysis confirmed that the FMD of the catheterized RA was dependent on days elapsed from the procedure (P = 0.032; OR 1.11, CI 0.009-0.203). Immunohistochemical evaluation showed extensive endothelial lesion in all examined RAs, with a trend towards reduction of the damage with time. Endothelial function and integrity of the cannulated arm did not reach those of the control arm in any of the study patients. RA-CA produces extensive damage to the RA. The lesions tend to heal with time but incomplete recovery of endothelial integrity and function is still present more than 30 days after the procedure. After RA-CA, the cannulated RA should not be used for CABG. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  1. Amiodaron in atrial fibrillation: post coronary artery bypass graft.

    Science.gov (United States)

    Habibollahi, Paria; Jam, Shahrzad Hashemi; Vahdati, Samad Shams; Baghi, Hamidreza Morteza; Amiri, Hassan

    2016-01-01

    Atrial fibrilation (AF) is the most common complication following heart surgeries; it often occurs in patients after coronary artery bypass graft (CABG). The purpose of this review is to categorize prophylaxes or treatment by administration of Amiodaron in patients with CABG. We searched google scholar, pubmed, and Cochrane Library databases (the period 1970-2010) for articles on Amiodaron in CABG and cardiac surgery. A total of 1 561 articles were identified, and 30 articles met the criteria and were enrolled in this review. Most studies supported Amiodarone for prophylaxi purpose in patients who were performed with CABG; few papers supported Amiodaron as a drug for treating CABG. The prophylaxis can decrease the incidence rate of AF in CABG, but if it uses as a treatment, the side effect of Amiodaron will decrease because all of the patients will not get Amiodarone. In the other hand use of Amiodarone as a treatment does not influence the length of hospital stay significantly but these kinds of study are so few. No appropriate therapeutic method has been defined for AF. At present, the common way of treating AF following cardiac surgery is mainly based on prophylaxis in medical books and references.

  2. PEEP-ZEEP technique: cardiorespiratory repercussions in mechanically ventilated patients submitted to a coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Auler José

    2011-09-01

    Full Text Available Abstract Background The PEEP-ZEEP technique is previously described as a lung inflation through a positive pressure enhancement at the end of expiration (PEEP, followed by rapid lung deflation with an abrupt reduction in the PEEP to 0 cmH2O (ZEEP, associated to a manual bilateral thoracic compression. Aim To analyze PEEP-ZEEP technique's repercussions on the cardio-respiratory system in immediate postoperative artery graft bypass patients. Methods 15 patients submitted to a coronary artery bypass graft surgery (CABG were enrolled prospectively, before, 10 minutes and 30 minutes after the technique. Patients were curarized, intubated, and mechanically ventilated. To perform PEEP-ZEEP technique, saline solution was instilled into their orotracheal tube than the patient was reconnected to the ventilator. Afterwards, the PEEP was increased to 15 cmH2O throughout 5 ventilatory cycles and than the PEEP was rapidly reduced to 0 cmH2O along with manual bilateral thoracic compression. At the end of the procedure, tracheal suction was accomplished. Results The inspiratory peak and plateau pressures increased during the procedure (p Conclusion The PEEP-ZEEP technique seems to be safe, without alterations on hemodynamic variables, produces elevated expiratory flow and seems to be an alternative technique for the removal of bronchial secretions in patients submitted to a CABG.

  3. RARE PRESENTATION OF SYMPTOMATIC BILATERAL PROXIMAL POPLITEAL ARTERY ANEURYSM

    Directory of Open Access Journals (Sweden)

    Thulasikumar Ganapathy

    2016-07-01

    Full Text Available True Popliteal artery aneurysm is the most common of all the peripheral artery aneurysms. We present a case of proximal popliteal artery aneurysm involvement both lower limb presented with gangrene in one lower limb and incapacitating claudication pain on the other lower limb. We have successfully repaired both sides aneurysm in the same sitting with Poly Tetra Fluro Ethylene (PTFE graft, as the patient also had multiple venous perforators’ involvement on both sides, which left us only with synthetic graft repair option rather than venous graft repair.

  4. The Prevalence of Risk Factors of Coronary Artery Disease in the Patients who Underwent Coronary Artery Bypass Graft, Shiraz, Iran: Suggesting a Model

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Ostovan

    2014-12-01

    Full Text Available Background: Cardiovascular diseases are the main cause of 40% of deaths in Iran annually. Many patients undergoing coronary artery bypass graft surgery have previous cardiovascular risk factors which could be prevented. Objectives: The present study aimed to assess the prevalence of cardiovascular risk factors in the patients undergoing coronary artery bypass graft surgery. Materials and Methods: In this cross-sectional (descriptive – analytical study, a data collecting form was used. A total of 246 patients were selected from six hospitals of Shiraz using random stratification. Descriptive statistics were presented through figures and tables and t-test was used to analyze the continuous variables. All the statistical analyses were performed using the SPSS statistical software (version 15.0. Besides, P < 0.05 was considered as statistically significant. Results: Among the study patients, only 11.67% had no risk factors and 88.33% had one or more risk factors. The most common risk factors observed in the patients were hypertension, obesity and overweight, hyperlipidemia, and diabetes mellitus. The results showed a significant difference between males and females regarding the prevalence of hypertension (P = 0.001, diabetes (P = 0.028, hypercholesterolemia (P = 0.020, and cigarette smoking (P = 0.001. In addition, the patients' mean levels of cholesterol, LDL, triglyceride, and fasting blood sugar were higher than the acceptable level, while that of HDL was lower than the accepted level. Conclusions:: These patients are recommended to be trained regarding lifestyle changes. Also, prevention strategies can play an important role in reducing patient morbidity and mortality.

  5. Comparing the effects of adaptive support ventilation and synchronized intermittent mandatory ventilation on intubation duration and hospital stay after coronary artery bypass graft surgery

    Directory of Open Access Journals (Sweden)

    Ahmadreza Yazdannik

    2016-01-01

    Full Text Available Background: Different modes of mechanical ventilation are used for respiratory support after coronary artery bypass graft (CABG. This study aimed to compare the effect(s of using adaptive support ventilation (ASV and synchronized intermittent mandatory ventilation (SIMV on the length of mechanical ventilation (intubation duration and hospital stay after coronary artery bypass graft surgery. Materials and Methods: In a randomized control trial, 64 patients were ventilated with ASV as the experiment group or with SIMV as the control group after CABG surgery in Chamran Hospital of Isfahan University of Medical Sciences. The time of tracheal intubation and the length of hospital stay were compared between the two groups. Data were analyzed and described using statistical analysis (independent t-test. Results: The mean time of intubation duration was significantly lower in ASV group compared with SIMV group. (4.83 h vs 6.71 h, P < 0.001. The lengths of hospital stay in the ASV and the SIMV groups were 140.6 h and 145.1 h, respectively. This difference was significant between the two groups (P = 0.006. Conclusions: According to the results of this study, using ASV mode for mechanical ventilation after CABG led to a decrease in intubation duration and also hospital stay in comparison with the SIMV group. It is recommended to use ASV mode on ventilators for respiratory support of patients undergoing coronary artery bypass graft surgery.

  6. Endovascular AAA exclusion: will stents with hooks and barbs prevent stent-graft migration?

    Science.gov (United States)

    Malina, M; Lindblad, B; Ivancev, K; Lindh, M; Malina, J; Brunkwall, J

    1998-11-01

    To investigate if stents with hooks and barbs will improve stent-graft fixation in the abdominal aorta. Sixteen- to 24-mm-diameter Dacron grafts were deployed inside cadaveric aortas. The grafts were anchored by stents as in endovascular abdominal aortic aneurysm repair. One hundred thirty-seven stent-graft deployments were carried out with modified self-expanding Z-stents with (A) no hooks and barbs (n = 75), (B) 4 5-mm-long hooks and barbs (n = 39), (C) 8 10-mm-long, strengthened hooks and barbs (n = 19), or (D) hooks only (n = 4). Increasing longitudinal traction was applied to determine the displacement force needed to extract the stent-grafts. The radial force of the stents was measured and correlated to the displacement force. The median (interquartile range) displacement force needed to extract grafts anchored by stent A was 2.5 N (2.0 to 3.4), stent B 7.8 N (7.4 to 10.8), and stent C 22.5 N (17.1 to 27.9), p barbs added anchoring strength. During traction, the weaker barbs were distorted or caused intimal tears. The stronger barbs engaged the entire aortic wall. The radial force of the stents had no impact on fixation, while aortic calcification and graft oversizing had marginal effects. Stent barbs and hooks increased the fixation of stent-grafts tenfold, while the radial force of stents had no impact. These data may prove important in future endograft development to prevent stent-graft migration after aneurysm exclusion.

  7. Early physical training and psycho-educational intervention for patients undergoing coronary artery bypass grafting. The SheppHeart randomized 2 × 2 factorial clinical pilot trial

    DEFF Research Database (Denmark)

    Højskov, Ida E; Moons, Philip; Hansen, Niels V

    2015-01-01

    BACKGROUND: Patients undergoing coronary artery bypass graft surgery often experience a range of problems and symptoms such as immobility, pain and insufficient sleep. Results from trials investigating testing in-hospital physical exercise or psychological intervention have been promising. However......, no randomized clinical trials have tested a comprehensive rehabilitation programme consisting of both physical exercise and psycho-education in the early rehabilitation phase. AIMS: The aims of the present SheppHeart pilot randomized clinical trial were to evaluate the feasibility of patient recruitment......, patient acceptance of the intervention, safety and tolerability of the intervention. METHODS AND DESIGN: Sixty patients admitted for coronary artery bypass graft were randomized 1:1:1:1 to: 1) physical exercise plus usual care, or 2) psycho-educational intervention plus usual care, or 3) physical exercise...

  8. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Stark, Christopher, E-mail: Christopher.stark@uvmhealth.org [University of Vermont Medical Center, Department of Radiology (United States); Olsen, Daniel [Mayo Clinic, Department of Pathology (United States); Morris, Christopher [University of Vermont Medical Center, Department of Radiology (United States); Bertges, Daniel [University of Vermont Medical Center, Department of Surgery (United States); Najarian, Kenneth [University of Vermont Medical Center, Department of Radiology (United States)

    2016-11-15

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  9. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    International Nuclear Information System (INIS)

    Stark, Christopher; Olsen, Daniel; Morris, Christopher; Bertges, Daniel; Najarian, Kenneth

    2016-01-01

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  10. Are two really always better than one? Results, concerns and controversies in the use of bilateral internal thoracic arteries for coronary artery bypass grafting in the elderly: a systematic review and meta-analysis.

    Science.gov (United States)

    Deo, Salil V; Altarabsheh, Salah E; Shah, Ishan K; Cho, Yang Hyun; McGraw, Michael; Sarayyepoglu, Basar; Medalion, Benjamin; Markowitz, Alan H; Park, Soon J

    2015-04-01

    Bilateral internal thoracic artery grafting appears to be the preferred method to achieve durable long-term coronary artery revascularization. However, data reporting the benefit of this technique in the elderly is very conflicting. We performed a systematic review of available literature (till November 2014) using multiple databases to identify studies comparing clinical events in patients undergoing coronary artery bypass grafting using either a single or double internal thoracic artery in the elderly. While early mortality was the primary end-point of inclusion, other adverse events compared were sternal wound infection (deep and superficial), stroke and peri-operative myocardial infarction. Individual and pooled odd's ratios were calculated using the Mantel-Haenzel method (random effect model); sensitivity analysis was performed. Results are presented using 95% confidence intervals. Nine retrospective studies (4479 BITA, 7733 LITA patients) fulfilled search criteria. Deep sternal wound infection was significantly higher after BITA harvest [OR 1.86 (1.3-2.5); I(2) = 0%; p < 0.01]. Early mortality (BITA 3.6% vs SITA 3.1%; p = 0.86), stroke [OR 0.7(0.4-1.1); p = 0.1], and peri-operative myocardial infarction (BITA 4.3% vs SITA 2.3%; p = 0.1) were comparable in both cohorts. Long-term survival favored the BITA cohort in two propensity matched studies. The incidence of deep sternal wound infection may be significantly higher after the harvest of both internal thoracic arteries in the elderly. While other post-operative adverse events are comparable, data regarding the long-term survival advantage in this cohort is conflicting. Hence, the use of both internal thoracic arteries in this age group needs to be invidualized. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  11. Electrospun polydioxanone-elastin blends: potential for bioresorbable vascular grafts

    Energy Technology Data Exchange (ETDEWEB)

    Sell, S A [Virginia Commonwealth University, Richmond, VA 23298 (United States); McClure, M J [Virginia Commonwealth University, Richmond, VA 23298 (United States); Barnes, C P [Virginia Commonwealth University, Richmond, VA 23298 (United States); Knapp, D C [Virginia Commonwealth University, Richmond, VA 23298 (United States); Walpoth, B H [University Hospital, 1211 Geneva 14 (Switzerland); Simpson, D G [Virginia Commonwealth University, Richmond, VA 23298 (United States); Bowlin, G L [Virginia Commonwealth University, Richmond, VA 23298 (United States)

    2006-06-15

    An electrospun cardiovascular graft composed of polydioxanone (PDO) and elastin has been designed and fabricated with mechanical properties to more closely match those of native arterial tissue, while remaining conducive to tissue regeneration. PDO was chosen to provide mechanical integrity to the prosthetic, while elastin provides elasticity and bioactivity (to promote regeneration in vitro/in situ). It is the elastic nature of elastin that dominates the low-strain mechanical response of the vessel to blood flow and prevents pulsatile energy from being dissipated as heat. Uniaxial tensile and suture retention tests were performed on the electrospun grafts to demonstrate the similarities of the mechanical properties between the grafts and native vessel. Dynamic compliance measurements produced values that ranged from 1.2 to 5.6%/100 mmHg for a set of three different mean arterial pressures. Results showed the 50:50 ratio to closely mimic the compliance of native femoral artery, while grafts that contained less elastin exceeded the suture retention strength of native vessel. Preliminary cell culture studies showed the elastin-containing grafts to be bioactive as cells migrated through their full thickness within 7 days, but failed to migrate into pure PDO scaffolds. Electrospinning of the PDO and elastin-blended composite into a conduit for use as a small diameter vascular graft has extreme potential and warrants further investigation as it thus far compares favorably to native vessel.

  12. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  13. Two Invasive Thymomas Incidentally Found during Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Navid Omidifar

    2016-01-01

    Full Text Available Thymoma, the most common neoplasm of the anterior mediastinum, is a rare tumor of thymic epithelium that can be locally invasive. We reported 2 cases of invasive thymoma incidentally found during routine coronary artery bypass graft (CABG surgery at Faghihee Hospital of Shiraz University of Medical Sciences of Iran in a period of about 6 months. The 2 patients were male and above 60 years old. They had no clinical symptoms and radiological evidence of mediastinal mass before detection of the tumor during operation. For both patients mass was completely excised and sent to the laboratory. The ultimate pathological diagnosis of both masses was invasive thymoma (stage 2. There are few reports in which thymomas were found incidentally during cardiac surgery. In spite of rare coincidence, due to being asymptomatic and possibly invasive, special attention to thymus gland during cardiac surgery or other mediastinal surgery and preoperative imaging studies seem to be reasonable approach.

  14. Complications of operative treatment of injuries of peripheral arteries.

    Science.gov (United States)

    Velinovic, M M; Davidovic, B L; Lotina, I S; Vranes, R M; Djukic, L P; Arsov, J V; Ristic, V M; Kocica, J M; Petrovic, L P

    2000-06-01

    In 1991 and 1992, a total of 97 patients with 106 peripherial arterial injuries underwent surgery at the Institute for Cardiovascular Diseases, Clinical Centre of Serbia. Civilian injuries accounted for 53 (54.6%) patients (94.3% males, age range: 16-63 yr, mean: 35.2), and 44 patients had war injuries (93.2% males, age range: 19-61 yr, mean: 34.8). The injuries affected the superfitial femoral artery in 31 (29.24%); the popliteal artery in 28 (26.41%); the brachial artery in 17 (16.04%); the posterior tibial artery in 6 (5.66%); the axillary artery in 5 (4.72%); the anterior tibial artery in 5 (4.72%); the tibioperoneal trunk in 4 (3. 77%); the common femoral artery in 4 (3.77%); the external iliac artery in 2 (1.89%); the profound femoral artery in 2 (1.89%); the radial artery in 1 (0.94%); and ulnar artery in 1 (0.94%).A total of 98 reconstructive procedures were used to treat these patients. Graft interposition carried out in 50 (51.02%); by pass in 25 (25. 51%); end-to-end anastomosis in 9 (9.18%); suture in 8 (8.16%); ligation in 4 (4.08%); and patch-angioplasty in 2 (2.04%). Primary reconstruction of injured arteries was performed in 72.2% and secondary repair in 27.8% cases. Infection developed in 51 (52.57%) patients, and it was significantly (P<0.05) more common in the war injuries (70.45%) and in secondary repairs (88.89%). The presence of associated lesions (69.56%) was also correlated with a greater rate of infection. Amputation was necessary in 21 (21.65%) of our patients, and was significantly (P<0.05) more often performed after secondary (44.44%) than primary operations (12.86%) and in the presence of associated injuries (32.61%).

  15. The experience of totally endoscopic coronary bypass grafting with the robotic system «Da Vinci» in Russia

    Science.gov (United States)

    Efendiev, V. U.; Alsov, S. A.; Ruzmatov, T. M.; Mikheenko, I. L.; Chernyavsky, A. M.; Malakhov, E. S.

    2015-11-01

    A new technology - a thoracoscopic coronary bypass grafting with the use of Da Vinci robotic system in Russia is represented by the experience of NRICP. The technology was introduced in Russia in 2011. Overall, one hundred endoscopic coronary artery bypass procedures were performed. We have compared and analyzed results of coronary artery stenting vs minimally invasive coronary artery bypass grafting. According to the results, totally endoscopic coronary artery bypass grafting has several advantages over alternative treatment strategies.

  16. Comparing cardiovascular factors in opium abusers and non-users candidate for coronary artery bypass graft surgery.

    Science.gov (United States)

    Aghadavoudi, Omid; Eizadi-Mood, Nastaran; Najarzadegan, Mohammad Reza

    2015-01-01

    In some opinions, opium consumption has traditionally been considered to be a means to lower blood lipids and to put off heart diseases. In this study, the relationship between opium consumption and risk factors of coronary artery diseases, hemodynamic factors and cardiac related functions before and after surgery was evaluated. In a cross-sectional study 325 patient's candidate for elective coronary artery bypass grafting were enrolled in a period of 6 months. Opium addicted patients were recognized based on taking history from the patients by an anaesthesiologist. Serum lipid profile was determined at the beginning of the study. Frequency and distribution of coronary artery diseases were assessed according to the pre-operative coronary angiography. From 325 patients, 117 patients were opium abusers and 208 patients were not. Mean duration of opium abuse was 12.6 ± 7.7 years. Mean total serum cholesterol levels were not significantly different in abusers and non-users patients (185 ± 47 vs. 190 ± 49, P > 0.05). Mean level of low-density lipoprotein cholesterol was significantly higher in addicted group (121 ± 27 vs. 81 ± 22, P opium addicted cases. Mean body mass index was also lower in addicted patients significantly (25.3 ± 3.7 vs. 27.5 ± 4.1, P opium abuse and aggravating lipid profile and hypercholesterolemia and coronary artery disease.

  17. Assessment of the usefulness of three-dimensional CT angiography after peripheral arterial bypass surgery

    International Nuclear Information System (INIS)

    Hayashi, Saihou; Sasaki, Masaru; Kawamoto, Jun

    1997-01-01

    Conventional CT and three-dimensional CT angiography (3D-CTA) were conducted after peripheral arterial bypass surgery on 17 patients (26 grafts) from October, 1994 to April, 1996. Seventeen grafts were patent. The following objectives were satisfied in these cases: 1. Prosthetic graft or saphenous vein was depicted by 3D-CTA, 2. The distal portion of the native artery was depicted by 3D-CTA, and 3. Opacification of the graft interior was recognized by transverse section of CT. Nine grafts were occluded but prosthetic grafts were depicted in 5 cases, and prosthetic grafts and the distal portions of native arteries in 3 cases. Opacification of the graft interior was not seen in any case. Achievement of the above three objectives was considered necessary to determine graft patency. (author)

  18. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  19. Successful Endovascular Treatment of a Left Common Carotid Artery Aneurysm Following Failed Surgery of a Right Common Carotid Artery Aneurysm

    International Nuclear Information System (INIS)

    Cil, Barbaros E.; Ucar, Ibrahim; Ozsoy, Fatma; Arat, Anil; Yorgancioglu, Cem; Boeke, Erkmen

    2005-01-01

    Aneurysm of the common carotid artery is a rare and serious disease requiring prompt treatment in order to avoid neurologic complications. A 39-year-old man presented with voice impairment and a pulsatile mass at the right side of his neck and was found by color Doppler examination to have bilateral common carotid artery aneurysms of unknown origin. The right-sided large aneurysm was treated with placement of an 8 mm interposition Gore-Tex graft between the right common and internal carotid arteries. The surgical graft thrombosed 7 days after the surgery but the left-sided aneurysm was successfully treated by a Jostent peripheral stent-graft. Color Doppler examination showed a patent stent and no filling of the aneurysm on his first and sixth-month follow-up. Bilateral common carotid artery aneurysm is an exceptionally unusual condition and endovascular treatment of carotid artery aneurysms with covered stents may become an effective treatment alternative for these lesions

  20. Early physical training and psycho-educational intervention for patients undergoing coronary artery bypass grafting. The SheppHeart randomized 2 × 2 factorial clinical pilot trial.

    Science.gov (United States)

    Højskov, Ida E; Moons, Philip; Hansen, Niels V; Greve, Helle; Olsen, Dorte Bæk; Cour, Søren La; Glud, Christian; Winkel, Per; Lindschou, Jane; Egerod, Ingrid; Christensen, Anne Vinggaard; Berg, Selina Kikkenborg

    2016-10-01

    Patients undergoing coronary artery bypass graft surgery often experience a range of problems and symptoms such as immobility, pain and insufficient sleep. Results from trials investigating testing in-hospital physical exercise or psychological intervention have been promising. However, no randomized clinical trials have tested a comprehensive rehabilitation programme consisting of both physical exercise and psycho-education in the early rehabilitation phase. The aims of the present SheppHeart pilot randomized clinical trial were to evaluate the feasibility of patient recruitment, patient acceptance of the intervention, safety and tolerability of the intervention. Sixty patients admitted for coronary artery bypass graft were randomized 1:1:1:1 to: 1) physical exercise plus usual care, or 2) psycho-educational intervention plus usual care, or 3) physical exercise and psycho-educational plus usual care, or 4) usual care alone during a four week period after surgery. The acceptability of trial participation was 67% during the three month recruitment period. In the physical exercise groups, patients complied with 59% of the total expected training sessions during hospitalization. Nine patients (30%) complied with >75% and nine patients (30%) complied with 50% of the planned exercise sessions. Eleven patients (42%) participated in ⩾75% of the four consultations and six patients (23%) participated in 50% of the psycho-educational programme. Comprehensive phase one rehabilitation combining physical exercise and psycho-education in coronary artery bypass graft patients shows reasonably high inclusion, feasibility and safety. © The European Society of Cardiology 2015.

  1. One Year Outcomes of 101 BeGraft Stent Grafts used as Bridging Stents in Fenestrated Endovascular Repairs.

    Science.gov (United States)

    Spear, Rafaelle; Sobocinski, Jonathan; Hertault, Adrien; Delloye, Matthieu; Azzauiu, Richard; Fabre, Dominique; Haulon, Stéphan

    2018-04-01

    To evaluate the outcomes of the second generation BeGraft balloon expandable covered stent Graft System (Bentley InnoMed, Hechingen, Germany) implanted as bridging stent grafts during fenestrated endovascular aortic repair (FEVAR) of complex aneurysms. This was a single centre prospective study including all consecutive patients treated by FEVAR performed with second generation BeGraft stent grafts as bridging stents. Demographics of patients, diameter and length of the bridging stent grafts, technical success, re-interventions, occlusions, post-operative events, and imaging (Cone Beam CT and/or CT scan, and contrast enhanced ultrasound) were prospectively collected in an electronic database. Duplex ultrasound was performed before discharge and at 6 month follow-up. At 1 year, patients were evaluated clinically and by imaging (CT and ultrasound). Between November 2015 and September 2016, 39 consecutive patients (one woman) were treated with custom made fenestrated endografts (2-5 fenestrations) for complex aneurysms or type 1 endoleak after EVAR, using a variety of bridging stents including the BeGraft. All 101 BeGraft stent grafts were successfully delivered and deployed. There was no in hospital mortality. Early fenestration patency rate was 99% (96/97); the sole target vessel post-operative occlusion was secondary to a dissection of the renal artery distal to the stent. Complementary stenting was unsuccessful in recovering renal artery patency; bilateral renal stent occlusion was observed in the same patient on a CT scan performed 2 months after the procedure. He required post-operative dialysis. No additional renal impairment was observed. During follow-up (median 13 months [11-15]), all fenestrations stented with BeGraft stent grafts remained patent (95/97, 98%). One type 1b endoleak was detected and treated (2.6%). BeGraft stent grafts used as bridging stents during FEVAR are associated with favourable outcomes at 1 year follow-up. Long-term follow-up is

  2. Effect of a virtual reality-enhanced exercise protocol after coronary artery bypass grafting.

    Science.gov (United States)

    Chuang, Tien-Yow; Sung, Wen-Hsu; Chang, Hwa-Ann; Wang, Ray-Yau

    2006-10-01

    Virtual reality (VR) technology has gained importance in many areas of medicine. Knowledge concerning the application and the influence of VR-enhanced exercise programs is limited for patients receiving coronary artery bypass grafting. The purpose of this study was to evaluate the effect of a virtual "country walk" on the number of sessions necessary to reach cardiac rehabilitation goals in patients undergoing coronary artery bypass grafting. Twenty subjects who were seen for cardiac rehabilitation between January and June 2004 comprised the study sample. The protocol for this study included an initial maximum graded exercise tolerance test, given to determine the subsequent training goals for the subject, followed by biweekly submaximal endurance training sessions. All subjects were assigned by lot to 1 of 2 submaximal endurance training programs, one (group 2) with and the other (group 1) without the added VR environment. In all other respects, the 2 programs were identical. Each training session lasted for 30 minutes and was carried out twice per week for about 3 months. The primary outcome measures were maximum load during the work sessions, target oxygen consumption, target heart rate (beats per minute), and number of training sessions required to reach rehabilitation goals. By the end of 20 training sessions, only 4 of the 10 control subjects had reached the heart rate target goal of 85% their maximum heart rate. In contrast, 9 of the 10 subjects in the VR program had attained this goal by 9 or fewer training sessions. When target metabolic cost (75% peak oxygen consumption) was used as the training goal, all 10 subjects in the VR program had reached this target after 2 training sessions (or, in some cases, 1 training session), but not until training session 15 did a cumulative number of 9 control subjects reach this goal. These study outcomes clearly support the notion that incorporating a VR environment into cardiac rehabilitation programs will accelerate

  3. Decline in health-related quality of life 6 months after coronary artery bypass graft surgery the influence of anxiety, depression, and personality traits

    NARCIS (Netherlands)

    Middel, B.; El Baz, N.; Pedersen, S.S.; van Dijk, J.P.; Wynia, K.; Reijneveld, S.A.

    2014-01-01

    Background: Although coronary artery bypass graft (CABG) is known to improve health-related quality of life (HRQoL), this improvement does not seem to be realized in all patients who had undergone CABG surgery. Objective: The aim of this study was to test the direct and indirect influence of

  4. Decline in Health-Related Quality of Life 6 Months After Coronary Artery Bypass Graft Surgery : The Influence of Anxiety, Depression, and Personality Traits

    NARCIS (Netherlands)

    Middel, Berrie; El Baz, Noha; Pedersen, Susanne S; van Dijk, Jitse P; Wynia, Klaske; Reijneveld, Sijmen A

    2014-01-01

    Background: Although coronary artery bypass graft (CABG) is known to improve health-related quality of life (HRQoL), this improvement does not seem to be realized in all patients who had undergone CABG surgery. Objective: The aim of this study was to test the direct and indirect influence of

  5. Effects of gravity-induced upper-limb blood pressure changes on wave transmission and arterial radial waveform.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Sanesi, Leandro; Gavish, Benjamin; Butlin, Mark; Avolio, Alberto; Schillaci, Giuseppe

    2016-06-01

    Local blood pressure (BP) changes induced by arm tilting may influence pressure wave transmission and reflection. We investigated the effects of upper-limb tilting on radial augmentation index (rAIx) and related central measures [aortic augmentation index (aAIx)]. In 45 volunteers (age 49 ± 19 years), supine brachial BP and radial artery waveforms were obtained by applanation tonometry with the dominant arm stretched and gently supported in three different positions: at the heart level, with the BP cuff 15 cm above heart level (approximately +30°), and 15 cm below heart level (-30°). Brachial SBP/DBP was 120/68 ± 17/8 mmHg. Mean arterial pressure changed predictably with arm tilting (99 ± 12 mmHg at -30°, 88 ± 10 mmHg at 0°, 77 ± 11 mmHg at +30°, all P < 0.001). rAIx decreased at -30° (69 ± 22%), and increased at +30° (93 ± 20%) compared with 0° (82 ± 20%, all P less than 0.001). Changes in rAIx (value at +30° minus value at -30°) showed an inverse relationship with age (r = -0.32, P = 0.03). Heart rate, BP and rAIx did not change in the contralateral arm, which was held at the heart level during the examination. aAIx followed the same pattern as rAIx (123 ± 27% at -30°, 144 ± 33% at +30°, 136 ± 31% at 0°, all P less than 0.001); changes in rAIx and aAIx were strongly related each other (r = 0.82, P < 0.001). Acute gravitational upper-limb BP changes generate opposite, profound changes in rAIx, and major artifactual changes in aAIx. These findings provide a rationale for recommending to keep the upper limb at the heart level during radial waveform assessment.

  6. Temporary diabetes insipidus in 2 men after on-pump coronary artery bypass grafting.

    Science.gov (United States)

    Uyar, Ihsan Sami; Sahin, Veysel; Akpinar, Besir; Yurtman, Volkan; Abacilar, Feyzi; Okur, Faik Fevzi; Ates, Mehmet

    2013-01-01

    Many complications have been reported after cardiopulmonary bypass. A common physiologic change during the early postoperative period after cardiopulmonary bypass is increased diuresis. In patients whose urine output is increased, postoperative diabetes insipidus can develop, although reports of this are rare. We present the cases of 2 patients who underwent on-pump coronary artery bypass grafting (with cardiopulmonary bypass). Each was diagnosed with diabetes insipidus postoperatively: a 54-year-old man on the 3rd day, and a 66-year-old man on the 4th day. Each patient recovered from the condition after 6 hours of intranasal therapy with synthetic vasopressin (antidiuretic hormone). The diagnosis of diabetes insipidus should be considered in patients who produce excessive urine early after cardiac surgery in which cardiopulmonary bypass has been used.

  7. Transit-time flow measurement as a predictor of coronary bypass graft failure at one year angiographic follow-up

    DEFF Research Database (Denmark)

    Lehnert, Per; Møller, Christian H; Damgaard, Sune

    2015-01-01

    on graft vessel type, anastomatic configuration, and coronary artery size. RESULTS: Nine hundred eighty-two coronary anastomoses were performed of which 12% had signs of graft failure at one year angiographic follow-up. In internal mammary arteries (IMAs), analysis showed a 4% decrease in graft failure......BACKGROUND: Transit-time flow measurement (TTFM) is a commonly used intraoperative method for evaluation of coronary artery bypass graft (CABG) anastomoses. This study was undertaken to determine whether TTFM can also be used to predict graft patency at one year postsurgery. METHODS: Three hundred...... forty-five CABG patients with intraoperative graft flow measurements and one year angiographic follow-up were analyzed. Graft failure was defined as more than 50% stenosis including the "string sign." Logistic regression analysis was used to analyze the risk of graft failure after one year based...

  8. Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts

    Directory of Open Access Journals (Sweden)

    Poulikakos Dimos

    2007-09-01

    Full Text Available Abstract Purpose Coronary artery bypass graft (CABG surgery represents the standard treatment of advanced coronary artery disease. Two major types of anastomosis exist to connect the graft to the coronary artery, i.e., by using an end-to-side or a side-to-side anastomosis. There is still controversy because of the differences in the patency rates of the two types of anastomosis. The purpose of this paper is to non-invasively quantify hemodynamic parameters, such as mass flow and wall shear stress (WSS, in end-to-side and side-to-side anastomoses of patients with CABG using computational fluid dynamics (CFD. Methods One patient with saphenous CABG and end-to-side anastomosis and one patient with saphenous CABG and side-to-side anastomosis underwent 16-detector row computed tomography (CT. Geometric models of coronary arteries and bypasses were reconstructed for CFD analysis. Blood flow was considered pulsatile, laminar, incompressible and Newtonian. Peri-anastomotic mass flow and WSS were quantified and flow patterns visualized. Results CFD analysis based on in-vivo CT coronary angiography data was feasible in both patients. For both types of CABG, flow patterns were characterized by a retrograde flow into the native coronary artery. WSS variations were found in both anastomoses types, with highest WSS values at the heel and lowest WSS values at the floor of the end-to-side anastomosis. In contrast, the highest WSS values of the side-to-side anastomosis configuration were found in stenotic vessel segments and not in the close vicinity of the anastomosis. Flow stagnation zones were found in end-to-side but not in side-to-side anastomosis, the latter also demonstrating a smoother stream division throughout the cardiac cycle. Conclusion CFD analysis of venous CABG based on in-vivo CT datasets in patients was feasible producing qualitative and quantitative information on mass flow and WSS. Differences were found between the two types of anastomosis

  9. Angioplasty in stenosis of the innominate artery

    International Nuclear Information System (INIS)

    Kobinia, G.S.; Bergmann, H. Jr.

    1983-01-01

    We describe a successful percutaneous transluminal dilatation (PTD) of an innominate artery stenosis in a 40-year-old patient with aortic arch syndrome. Five years earlier both a left central carotid artery occlusion and an innominate and left subclavian artery stenosis were treated by grafting from the aorta to the distal vessels. At recurrence of the neurological symptoms, reocclusion of the graft to the innominate artery and subtotal stenosis of the left carotid anastomosis were noted. The prevent the hazards of a reoperation, the innominate artery stenosis was dilated by means of PTD via the right brachial artery. Success of the procedure was demonstrated by Doppler sonography and angiography. It appears that PTD serves as an excellent method of treating stenoses of the aortic arch branches in aortic arch syndrome. (orig.)

  10. Pneumoproteins as a lung-specific biomarker of alveolar permeability in conventional on-pump coronary artery bypass graft surgery vs mini-extracorporeal circuit - A pilot study

    NARCIS (Netherlands)

    van Boven, WJP; Gerritsen, WBM; Zanen, P; Grutters, JC; van Dongen, HPA; Bernard, A; Aarts, LPHJ

    Background: Despite improvements of the heart-lung machine (HLM), oxidative stress and subsequent damage to the alveolar capillary membrane still occur after conventional on-pump coronary artery bypass graft (CCABG) surgery. In an attempt to further improve the conventional HLM, a

  11. One-year results of total arterial revascularization vs. conventional coronary surgery: CARRPO trial

    DEFF Research Database (Denmark)

    Damgaard, Sune; Wetterslev, Jørn; Lund, Jens T

    2009-01-01

    +/- 18% in the conventional group (P = 0.52). In 72% of TAR patients and 67% of the conventional group, all grafts were patent (P = 0.45). Multiple imputation of missing angiographic data did not influence on results. Within 1 year, 37 (23%) TAR patients and 43 (25%) conventional group patients suffered...... cardiac events (HR 1.09, 95% CI 0.70-1.69, P = 0.70). One patient (0.6%) in the TAR group and two (1.2%) in the conventional group died (P = 1.00). CONCLUSION: Within 1 year post-operatively, TAR seems at least as safe and effective as CR. Prolonged follow-up will reveal whether this is sustained......AIMS: To investigate clinical and angiographic outcomes after coronary surgery using total arterial revascularization (TAR). METHODS AND RESULTS: We randomized 331 patients with multivessel or isolated left main disease to TAR [internal thoracic (ITA) and radial arteries] vs. conventional...

  12. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  13. Cardiovascular risk profile before coronary artery bypass graft surgery in relation to depression and anxiety disorders: An age and sex propensity matched study.

    Science.gov (United States)

    Tully, Phillip J; Newland, Richard F; Baker, Robert A

    2015-02-01

    The cardiovascular risk profile and postoperative morbidity outcomes of anxiety disorder patients undergoing coronary artery bypass surgery is not known. In a cross-sectional design, 114 consecutive coronary artery bypass graft surgery patients were evaluated to create four matched groups (30 with anxiety disorder, 27 with depression disorder and 57 age-sex matched coronary artery bypass surgery control patients with no depression or anxiety disorder). By comparison to non-depression disorder age-sex matched controls, depressed patients presented for coronary artery bypass surgery with significantly greater myocardial inflammatory markers (Troponin T>02, 33.3% vs. 11.1%, p=.03), metabolic risk (body surface area>35 (22.2% vs. 0%, p=.03), comorbid cardiovascular risk (peripheral vascular disease 18.5% vs. 0%, p=.05). Depressed patients also recorded longer intraoperative time at higher temperatures >37°C on cardiopulmonary bypass (11.1 ± 9.0 vs. 6.0 ± 4.9, pPatients with anxiety disorder on the other hand presented with significantly higher Creatinine Kinase-Muscle Brain (5 IQR 4-5 ng/ml vs. 4 IQR 3-4 ng/ml, p=.04), higher intraoperative glucose levels (7.8 ± 2.5 mmol/l vs. 7.0 ± 1.2 mmol/l, p=.05), and received fewer grafts (2.1 ± .9 vs. 2.5 ± .9 p=.04). A differential cardiovascular risk profile and postoperative outcome was observed dependent on anxiety and depression disorder status. There were few modifiable cardiovascular risk factors at the time of surgery other than psychiatric status, perioperative management of depression and anxiety may have promise to reduce further cardiac morbidity after coronary artery bypass surgery. Copyright © 2014. Published by Elsevier Ltd.

  14. Pseudarthrosis of radial shaft with dislocation of heads of radial and ulnar bones (case report

    Directory of Open Access Journals (Sweden)

    M. E. Puseva

    2013-01-01

    Full Text Available The authors presented a rare clinical case - the injury of forearm complicated by the formation of the pseudarthrosis of the radial shaft in combination with old dislocation of heads the radius and ulna. The differentiated approach to the choice of surgical tactics was proposed, which consists of several consistent stages: taking free autotransplant from the crest of iliac bone, resection of pseudarthrosis of radius with replacement of the bone defect by the graft for restoration of anatomic length, conducting combined strained osteosynthesis and elimination of dislocation of a head of radial and ulnar bones by transosseous osteosynthesis. The chosen treatment strategy allowed to restore the anatomy and function of the upper extremity.

  15. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  16. Spinal arterial anatomy and risk factors for lower extremity weakness following endovascular thoracoabdominal aortic aneurysm repair with branched stent-grafts.

    Science.gov (United States)

    Chang, Catherine K; Chuter, Timothy A M; Reilly, Linda M; Ota, Maile K; Furtado, Andre; Bucci, Monica; Wintermark, Max; Hiramoto, Jade S

    2008-06-01

    To evaluate spinal arterial anatomy and identify risk factors for lower extremity weakness (LEW) following endovascular thoracoabdominal aortic aneurysm (TAAA) repair. A retrospective review was conducted of 37 patients (27 men; mean age 74.8+/-7.1 years, range 58-86) undergoing endovascular TAAA repair with branched stent-grafts at a single academic institution from July 2005 to December 2007. Data were collected on preoperative comorbidities, duration of operation, blood loss, type of anesthesia, extent of aortic coverage, blood pressure, cerebrospinal fluid (CSF) pressure and drainage, and postoperative development of LEW. Pre- and postoperative contrast-enhanced computed tomographic angiograms (CTA) in a 26-patient subset were analyzed to evaluate the number of patent intercostal and lumbar arteries before and after repair. All patients were neurologically intact at the end of the operation. Seven (19%) patients developed LEW postoperatively: 6 perioperatively and 1 after discharge. LEW was associated with postoperative hypotension, internal iliac artery (IIA) occlusion, and fewer patent segmental arteries on preoperative CTA. Lowest mean systolic blood pressure was segmental arteries in patients with or without LEW. Endovascular TAAA repair inevitably occludes direct inflow to lumbar and intercostal arteries. The distal segments of these arteries to the spine, however, are seen to remain patent through collaterals. Measures to preserve collateral pathways and increase perfusion pressure may help prevent or treat LEW.

  17. Hepatorenal bypass using autogenous, free internal iliac artery graft: An attractive alternative to revascularize the right kidney in Takayasu′s disease

    Directory of Open Access Journals (Sweden)

    Nikhil Khattar

    2012-01-01

    Full Text Available Nonspecific aortoarteritis or Takayasu′s disease (TD is a chronic pan endarteritis of unknown origin involving the aorta and its major branches affecting young adults especially women. The disease is more common in eastern Asian countries. Hypertension in these patients generally reflects as renal artery stenosis, which is seen in 28-75% of patients. Surgical revascularization is occasionally needed in patients with failed medical management or endovascular interventions. We report two cases of Takayasu′s arteritis in young women where renal revascularization was done using free internal iliac artery hepatorenal bypass graft with excellent control of hypertension in the postoperative period.

  18. Coronary artery bypass grafting versus percutaneous intervention in coronary revascularization: a historical perspective and review

    Directory of Open Access Journals (Sweden)

    Burgess SN

    2015-06-01

    Full Text Available Sonya N Burgess,1 John J Edmond,2 Craig P Juergens,1 John K French11Department of Cardiology, Liverpool Hospital and South Western Sydney Clinical School, The University of New South Wales, Sydney, NSW, Australia; 2Department of Cardiology, Dunedin Public Hospital, Dunedin, New Zealand Background: Coronary artery bypass graft surgery is arguably the most intensively studied surgical procedure, and percutaneous coronary intervention (PCI has been subjected to more randomized clinical trials than any other interventional procedure. Changes seen in revascularization techniques have been numerous. The rapid evolution of evidence-based revascularization procedures has occurred as a result of many pivotal large randomized clinical trials. Objective: This review compares and contrasts outcomes from two coronary revascularization techniques, coronary artery bypass grafting (CABG and PCI, with particular reference to the landmark trials that inform practice guidelines. Methods: We undertook a comprehensive review of published literature addressing trials in this field performed to address current knowledge both in the predrug-eluting stent and postdrug-eluting stent era. Results and discussion: Surgical and percutaneous revascularization strategies have different strengths and weaknesses, and neither strategy is superior in all patients, clinical presentations, or anatomical subgroups. Current data support the use of percutaneous intervention in ST elevation myocardial infarction and in single-vessel disease. In noncomplex multivessel disease and isolated left main stem PCI, the data support non-inferiority of PCI compared to CABG as reflected in the 2014 European Society of Cardiology guidelines. Landmark revascularization trials of multivessel disease comparing CABG to PCI found no survival benefit to CABG over PCI, except in patients with complex disease. In these trials, revascularization drove differences in primary endpoints and in all but the

  19. Re-birth after coronary bypass graft surgery: a hermeneutic-phenomenological study.

    Science.gov (United States)

    Abbasi, Mohammad; Mohammadi, Nooredin; Nasrabadi, Alireza Nikbakht; Fuh, Suh Boudouin; Sadeghi, Tahereh

    2014-03-31

    Although coronary artery bypass graft surgery has significant effects on reducing the symptoms of coronary artery disease, there is not enough knowledge and understanding of lived experience of patients after surgery. Understanding lived experience of this group of patients would be helpful for healthcare staff to provide better services to the patients. The aim of this study was to describe with a deeper understanding, the lived experiences of patients after Coronary Artery Bypass Graft Surgery. Using a hermeneutic phenomenological approach and a Van-Manen analysis method, in-depth semi-structured interviews were conducted with eleven participants who had lived experienced of at least six months post - coronary artery bypass graft surgery. Re-birth was the main theme that emerged in the process of data analysis. This theme was derived from four sub-themes including "feels younger", ''vigorous heart'', ''intrepid life'' and ''oriented to be healthy''. Life after a coronary artery bypass graft surgery is often appreciated as a re-birth by persons with these experiences as surgery did not only provide a feeling of wellness, but also added a sensation of youthfulness and improvement in the quality of life for these participants. In addition, they would actively participate in health promotional activities such as; adherence to medication and diet regimes, changes in lifestyle to maintain their health.

  20. Using radionuclide imaging for monitoring repairment of bone defect with tissue-engineered bone graft in rabbits

    International Nuclear Information System (INIS)

    Xia Changsuo; Ye Fagang; Zou Yunwen; Ji Shixiang; Wang Dengchun

    2004-01-01

    Objective: To observe the effect of tissue-engineered bone grafts in repairing bone defect in rabbits, and assess the value of radionuclide for monitoring the therapeutic effect of this approach. Methods: Bilateral radial defects of 15 mm in length in 24 rabbits were made. The tissue-engineered bone grafts (composite graft) contained bone marrow stromal cells (BMSCs) of rabbits and calcium phosphate cement (CPC) were grafted in left side defects, CPC only grafts (artificial bone graft) in right defects. After the operation, radionuclide was used to monitor the therapeutic effects at 4, 8 and 12 weeks. Results: 99 Tc m -methylene diphosphonic acid (MDP) radionuclide bone imaging indicated that there was more radionuclide accumulation in grafting region of composite than that of CPC. There was significant difference between 99 Tc m -MDP uptake of the region of interest (ROI) and scintillant counts of composite bone and the artificial bone (P<0.01). Conclusion: Tissue-engineered bone grafts is eligible for repairing radial bone defects, and radionuclide imaging may accurately monitor the revascularization and bone regeneration after the bone graft implantation. (authors)

  1. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki [Social Insurance Chukyo Hospital, Nagoya (Japan)

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients

  2. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    International Nuclear Information System (INIS)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients with

  3. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Science.gov (United States)

    Chan, Alex H P; Tan, Richard P; Michael, Praveesuda L; Lee, Bob S L; Vanags, Laura Z; Ng, Martin K C; Bursill, Christina A; Wise, Steven G

    2017-01-01

    Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL) we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM) analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP). This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days). We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  4. Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

    Directory of Open Access Journals (Sweden)

    Alex H P Chan

    Full Text Available Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP. This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days. We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

  5. Guillain-Barré Syndrome after Coronary Artery Bypass Graft Surgery: a Case Report.

    Science.gov (United States)

    Hekmat, Manouchehr; Ghaderi, Hamid; Foroughi, Mahnoosh; Mirjafari, S Adeleh

    2016-01-01

    Guillain-Barre syndrome is a neurologic disorder that may appear after infection or major surgery. Guillain-Barré syndrome following cardiac surgery is rare and only based on case reports, and we review all of the published cases. A 52-year-old man after 5 months suffering from chest pain was referred to our hospital and underwent coronary artery bypass graft for 3 vessel disease. The patient was discharged without complication on the 5th postoperative day. He presented Guillain-Barré syndrome after 12 months. He has not completely recovered weakness of upper extremities grade 4/5 with atrophy of both upper extremities remains after 18 months. This disorder is similar to classic GBS. It is important to be alert to de novo autoimmune neurological disorders after cardiac surgery. These disorders are similar to classic autoimmune disease and treated with standard therapies.

  6. An alternative graft fixation technique for scaphoid nonunions treated with vascular bone grafting.

    Science.gov (United States)

    Korompilias, Anastasios V; Lykissas, Marios G; Kostas-Agnantis, Ioannis P; Gkiatas, Ioannis; Beris, Alexandros E

    2014-07-01

    To present our experience with vascularized bone grafting based on the 1,2-intercompartmental supraretinacular artery for the management of established scaphoid nonunion and to investigate the efficacy of graft immobilization with a combination of Kirschner wires and transarticular external fixation. A retrospective chart and radiographic review was conducted for patients with the diagnosis of scaphoid nonunion of the proximal pole or the waist treated with the 1,2-intercompartmental supraretinacular artery-based vascularized graft and fixed with a combination of Kirschner wires and transarticular external fixation between 2007 and 2011. We observed 23 consecutive patients for a mean of 34 ± 4 months. All patients were males with mean age of 25 ± 5 years. All patients had scaphoid nonunion and associated humpback deformity. The mean duration of nonunion was 7 ± 1 months. All scaphoid nonunions united after the index procedure at a mean of 10 ± 1 weeks. Two patients had avascular necrosis of the proximal pole based on the preoperative magnetic resonance imaging findings. After surgery, deformity correction was achieved in all patients, as recorded by the decrease in the lateral intrascaphoid angle and the increase in the dorsal scaphoid angle. At the last follow-up, no patients reported wrist pain. The mean Disabilities of the Arm, Shoulder, and Hand score improved significantly from 32 ± 12 before the operation to 5 ± 3 at the last postoperative visit. All patients showed statistically significant improvement in the range of motion and the grip strength of the involved wrist. The results of this study support the combined use of Kirschner wires and transarticular external fixation for fixation of a 1,2-intercompartmental supraretinacular artery-based vascular bone graft in the treatment of scaphoid nonunions. Therapeutic IV. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  7. On-Pump Versus Off-Pump Coronary Artery Bypass Surgery in Elderly Patients

    DEFF Research Database (Denmark)

    Houlind, Kim; Kjeldsen, Bo Juul; Madsen, Susanne Nørgaard

    2012-01-01

    BACKGROUND: Conventional coronary artery bypass grafting performed with the use of cardiopulmonary bypass is a well-validated treatment for patients with ischemic heart disease. Off-pump coronary artery bypass grafting (OPCAB) has been suggested to reduce the number of perioperative complications......, especially in elderly patients. METHODS AND RESULTS: In a multicenter, randomized trial, we assigned 900 patients >70 years of age to conventional coronary artery bypass grafting or OPCAB surgery. After 30 days, a blinded end-point committee assessed whether a combined end point of death, stroke...... experiencing the combined end point within 30 days was 10.2% for conventional coronary artery bypass grafting and 10.7% for OPCAB. Implied risk difference of 0.4% (with a 95% confidence interval, -3.6 to 4.4) showed nonsignificance in a standard test for equality (P=0.83) and for noninferiority...

  8. The implantation of separating aortic stent-graft into the canine thoracic aorta: an experimental study

    International Nuclear Information System (INIS)

    Xia Jinguo; Shi Haibin; Yang Zhengqiang; Li Chao; Liu Sheng; Zu Qingquan; Li Linsun

    2011-01-01

    Objective: to assess the technical feasibility of implanting separating stent-graft into the canine thoracic aorta and to study its biocompatibility. Methods: Twelve adult dogs were randomly and equally divided into three groups. The right femoral artery was cut open, through which the separating stent-graft was inserted and deployed in the canine thoracic aorta, with the proximal end of the graft being quite close to the origin of the left subclavian artery. the technical feasibility of the deployment process was assessed. Angiography was performed at 4, 8 and 12 weeks after stent-graft placement to evaluate the position and patency of the stent-graft. Then the dogs were sacrificed and the specimens were collected for pathologic study. Both gross and microscopic examinations were made to evaluate the fixation of the stent-graft with the vessel wall, the endothelialization of stent-graft surface and the pathologic changes of the vascular wall. Results: A total of ten separating stent-grafts were successfully deployed in the canine thoracic aorta, no migration or deformation occurred. One dog died of massive bleeding due to the rupture of the right femoral artery which occurred when the delivery system containing the inner bare stent was inserted through the right femoral artery. Death occurred in another dog as a result of the ascending aorta rupture caused by the migration of outer-layer stent-graft. Angiography was conducted at 4, 8 and 12 weeks after stent-graft placement. No migration, deformation, rupture or stenosis of the implanted stent-grafts were observed. The formation of intima on the inner surface of the bare stent appeared at 4 weeks, which became more and more obvious with the time passing, and at 12 weeks complete endothelialization of stent-graft surface was observed. Conclusion: Technically, it is feasible to deploy the separating aortic stent-graft into the canine thoracic aorta. Moreover, the separating aortic stent-graft carries excellent

  9. Intravenous digital subtraction angiography of transplanted kidney artery

    International Nuclear Information System (INIS)

    Tessier, J.P; Teyssou, H.; Verdier, J.P.; Tison, E.; Meyblum, J.; Marchal, M.

    1986-01-01

    Results of 351 intravenous digital subtraction angiographs (AN) of transplanted kidneys emphasized reliability of this examination for detection of renal artery stenosis. A prospective study of 219 patients (188 interpretable AN) showed significant stenosis of grafted artery in 22% of cases: 17% of the 126 patients with normal blood pressure and 34% of the 62 cases of hypertension. Digital subtraction allows, with a single injection, assessment of renal artery, nephrogram and excretory cavities, but it is not a substitute for conventional intravenous urography 1 to 2 months after grafting [fr

  10. Juxtarenal Modular Aortic Stent Graft Infection Caused by Staphylococcus aureus

    Directory of Open Access Journals (Sweden)

    Róbert Novotný

    2016-01-01

    Full Text Available Introduction. We are presenting a case report of an infected modular abdominal stent graft. Case Presentation. A 67-year-old male patient three years after Cook’s modular abdominal aortic aneurysm (AAA graft implantation for juxtarenal AAA with an implantation of a stent extension into the right common iliac artery for type Ib endoleak. The patient was admitted into our center in severe condition with suspected retroperitoneal bleeding. Computed tomography angiography (CTAG confirmed retroperitoneal bleeding in the right common iliac artery. An urgent surgical revision was indicated; destructed arterial wall around the stent extension in the right common iliac artery was discovered. Due to the severe state of health of the patient, a resection of the infected stent and affected arterial wall was performed, followed by an iliac-femoral crossover bypass. The patient was transported to the intensive care unit with hepatic and renal failure, with maximal catecholamine support. Combined antibiotic treatment was started. The patient died five hours after the procedure. The cause of death was multiorgan failure caused by sepsis. Hemocultures and perioperative microbiological cultures showed the infection agent to be Staphylococcus aureus methicillin sensitive. Conclusion. Stent graft infection is a rare complication. Treatment is associated with high mortality and morbidity.

  11. [Minimally invasive coronary artery surgery].

    Science.gov (United States)

    Zalaquett, R; Howard, M; Irarrázaval, M J; Morán, S; Maturana, G; Becker, P; Medel, J; Sacco, C; Lema, G; Canessa, R; Cruz, F

    1999-01-01

    There is a growing interest to perform a left internal mammary artery (LIMA) graft to the left anterior descending coronary artery (LAD) on a beating heart through a minimally invasive access to the chest cavity. To report the experience with minimally invasive coronary artery surgery. Analysis of 11 patients aged 48 to 79 years old with single vessel disease that, between 1996 and 1997, had a LIMA graft to the LAD performed through a minimally invasive left anterior mediastinotomy, without cardiopulmonary bypass. A 6 to 10 cm left parasternal incision was done. The LIMA to the LAD anastomosis was done after pharmacological heart rate and blood pressure control and a period of ischemic pre conditioning. Graft patency was confirmed intraoperatively by standard Doppler techniques. Patients were followed for a mean of 11.6 months (7-15 months). All patients were extubated in the operating room and transferred out of the intensive care unit on the next morning. Seven patients were discharged on the third postoperative day. Duplex scanning confirmed graft patency in all patients before discharge; in two patients, it was confirmed additionally by arteriography. There was no hospital mortality, no perioperative myocardial infarction and no bleeding problems. After follow up, ten patients were free of angina, in functional class I and pleased with the surgical and cosmetic results. One patient developed atypical angina on the seventh postoperative month and a selective arteriography confirmed stenosis of the anastomosis. A successful angioplasty of the original LAD lesion was carried out. A minimally invasive left anterior mediastinotomy is a good surgical access to perform a successful LIMA to LAD graft without cardiopulmonary bypass, allowing a shorter hospital stay and earlier postoperative recovery. However, a larger experience and a longer follow up is required to define its role in the treatment of coronary artery disease.

  12. Unintentional arterial puncture during cephalic vein cannulation: case report and anatomical study

    NARCIS (Netherlands)

    Lirk, P.; Keller, C.; Colvin, J.; Colvin, H.; Rieder, J.; Maurer, H.; Moriggl, B.

    2004-01-01

    The cephalic antebrachial vein is often used for venous access. However, superficial radial arteries of the forearm are known and unintentional arterial puncture can result from attempts to cannulate the lateral veins of the arm. Accidental puncture of a superficial radial artery during peripheral

  13. Results of Infrageniculate Bypasses Using the Profunda Femoris Artery as Inflow Source.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; Pizzardi, Giulia; Pasqua, Rocco; Masci, Federica; Frezzotti, Francesca; Palumbo, Piergaspare; Vietri, Francesco

    2018-02-01

    When the common femoral artery is not accessible for infrainguinal bypass grafting, the profunda femoris artery (PFA) can be a valuable alternative inflow source for distal arterial revascularization. The purpose of this retrospective study was to evaluate the results of infrageniculate bypass grafting via the PFA as inflow source for critical limb ischemia. Between 1994 and 2016, 68 patients, 51 men of a mean age of 74 years, underwent an infrageniculate arterial bypass grafting for critical limb ischemia, using the PFA as inflow site. PFA was exposed at the Scarpa's triangle in 38 patients (56%) and at its medio-crural segment in 30 patients (44%). The distal anastomosis was performed on the infragenicular popliteal artery in 33 patients (48%), the peroneal artery in 14 patients (20%), the tibioperoneal trunk in 8 patients (12%), the posterior tibial artery in 8 patients (12%), and the dorsalis pedis artery in 5 patients (8%). The graft material consisted of a reversed great saphenous vein (GSV) in 62 patients (91%) and a 6-mm polytetrafluoroethylene graft in 6 patients (9%). The median duration of follow-up was 51 months (range, 6-72 months). As main results, postoperative mortality and morbidity, overall late patients' survival, primary grafts' patency, and limb salvage rate were considered. Operative mortality and morbidity were 3% and 4%, respectively. Overall patients' survival, primary patency and limb salvage rate, at 36 and 60 months were, respectively, 62% and 53%, 66% and 59%, and 92% and 77%. The PFA, both exposed at the Scarpa's triangle and at mid-thigh, is an excellent inflow source for infrageniculate revascularizations. It should remain an important part of the technical armamentarium of vascular surgeons, even in the endovascular era. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Pleural subxyphoid drain confers better pulmonary function and clinical outcomes in chronic obstructive pulmonary disease after off-pump coronary artery bypass grafting: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Solange Guizilini

    2014-12-01

    Full Text Available Objective: To evaluate the lung function and clinical outcome in severe chronic obstructive pulmonary disease in patients undergoing off-pump coronary artery bypass grafting with left internal thoracic artery graft, comparing the pleural drain insertion in the intercostal versus subxyphoid region. Methods: A randomized controlled trial. Chronic obstructive pulmonary disease patients were randomized into two groups according pleural drain site: II group (n=27 - pleural drain in intercostal space; SI group (n=29 - pleural drain in the subxyphoid region. Spirometry values (Forced Vital Capacity - and Forced expiratory volume in 1 second were obtained on preoperative and 1, 3 and 5 postoperative days. Chest x-ray from preoperative until postoperative day 5 (POD5 was performed for monitoring respiratory events, such as atelectasis and pleural effusion. Pulmonary shunt fraction and pain score was evaluate preoperatively and on postoperative day 1. Results: In both groups there was a significant decrease of the spirometry values (Forced Vital Capacity and Forced expiratory volume in 1 second until POD5 (P<0.05. However, when compared, SI group presented less decrease in these parameters (P<0.05. Pulmonary shunt fraction was significantly lower in SI group (P<0.05. Respiratory events, pain score, orotracheal intubation time and postoperative length of hospital stay were lower in the SI group (P<0.05. Conclusion: Subxyphoid pleural drainage in severe Chronic obstructive pulmonary disease patients determined better preservation and recovery of pulmonary capacity and volumes with lower pulmonary shunt fraction and better clinical outcomes on early postoperative off-pump coronary artery bypass grafting.

  15. Early ventricular tachyarrhythmias after coronary artery bypass grafting surgery: Is it a real burden?

    Science.gov (United States)

    Mouws, Elisabeth M J P; Yaksh, Ameeta; Knops, Paul; Kik, Charles; Boersma, Eric; Bogers, Ad J J C; de Groot, Natasja M S

    2017-09-01

    The prevalence of ventricular dysrhythmias (VD) [ventricular premature beats (VPBs), ventricular couplets (Vcouplets), ventricular runs (Vruns)] after coronary artery bypass grafting (CABG) has so far not been examined. The goal of this study is to examine characteristics of VD and whether they precede ventricular tachyarrhythmias (VTA) during a postoperative follow-up period of 5 days using continuous rhythm registrations. In addition, we determined predictive factors of VD/VTA. Incidences and burdens of VD/VTA were calculated in patients (N=105, 83 male, 65±9 years) undergoing primary, on-pump CABG. Independent risk factors were examined using multivariate analysis. VPBs, Vcouplets, and Vruns occurred in respectively 100%, 82.9%, and 48.6% with corresponding burdens of 0.05%, 0%, and 0%. Sustained ventricular tachycardia (VT) and ventricular fibrillation (VF) did not occur in our cohort. Independent risk factors for VD included male gender, mitral valve insufficiency, hyperlipidemia, and age ≥60 years. VD are common in patients with coronary artery disease after CABG. Despite high incidences of these dysrhythmias, corresponding burdens are low and sustained VT or VF did not occur. Incidences were highest on the first postoperative day and diminished over time. Copyright © 2017 Japanese College of Cardiology. Published by Elsevier Ltd. All rights reserved.

  16. Cirurgia de revascularização do miocárdio minimamente invasiva com uso de enxerto composto: relato de caso Use of compound grafts in minimally invasive coronary artery bypass graft

    Directory of Open Access Journals (Sweden)

    Fábio B Jatene

    1996-12-01

    Full Text Available Este trabalho relata nossa experiência com a utilização de enxerto composto em cirurgia de revascularização do miocárdio minimamente invasiva (CRMMI. Uma alternativa para a CRMMI é o uso de enxertos compostos, nos casos em que se pretende revascularizar vários ramos coronarianos, quando a artéria torácica interna se apresenta curta ou ramifica-se precocemente. Foi operada paciente do sexo feminino, 54 anos, portadora de lesão de 90% em artéria interventricular anterior em seu terço proximal e que foi submetida à CRMMI por minitoracotomia esquerda. A artéria torácica interna esquerda (ATIE foi amplamente dissecada utilizando-se bisturi longo, auxílio de ótica de videotoracoscopia e clipe para ligadura dos ramos intercostais. Após a secção da ATIE houve ausência de fluxo sangüíneo e evidência de hematoma e dissecção da sua luz no terço distai. Este segmento comprometido foi desprezado e a ATIE foi prolongada por interposição de segmento de veia safena autógena, tornando possível a anastomose com o ramo interventricular anterior. A operação teve duração de 3 horas. A paciente foi extubada após 4 horas de pós-operatório e o dreno pleural esquerdo foi retirado no 3º dia; a paciente evoluiu bem, não apresentando intercorrências clínicas pós-operatórias, tendo recebido alta hospitalar 5 dias após a operação. A cineangiocoronariografia pós-operatória comprovou anastomose patente. O estudo com ecodoppler realizado no 4º mês de pós-operatbrio mostrou derivação pérvia e fluxo de alta resistência. Em conclusão, o uso de enxerto composto para CRMMI mostrou ser uma alternativa eficaz para ampliar a extensão da ATIE, possibilitando a anastomose, quando a mesma é curta ou apresenta problemas de fluxo ou, ainda, se se pretende tratar mais de uma coronáriaThis paper reports our experience with the use of compound grafts in minimally invasive coronary artery bypass graft (MICABG. An alternative for

  17. Long-Term Survival Prediction for Coronary Artery Bypass Grafting: Validation of the ASCERT Model Compared With The Society of Thoracic Surgeons Predicted Risk of Mortality.

    Science.gov (United States)

    Lancaster, Timothy S; Schill, Matthew R; Greenberg, Jason W; Ruaengsri, Chawannuch; Schuessler, Richard B; Lawton, Jennifer S; Maniar, Hersh S; Pasque, Michael K; Moon, Marc R; Damiano, Ralph J; Melby, Spencer J

    2018-05-01

    The recently developed American College of Cardiology Foundation-Society of Thoracic Surgeons (STS) Collaboration on the Comparative Effectiveness of Revascularization Strategy (ASCERT) Long-Term Survival Probability Calculator is a valuable addition to existing short-term risk-prediction tools for cardiac surgical procedures but has yet to be externally validated. Institutional data of 654 patients aged 65 years or older undergoing isolated coronary artery bypass grafting between 2005 and 2010 were reviewed. Predicted survival probabilities were calculated using the ASCERT model. Survival data were collected using the Social Security Death Index and institutional medical records. Model calibration and discrimination were assessed for the overall sample and for risk-stratified subgroups based on (1) ASCERT 7-year survival probability and (2) the predicted risk of mortality (PROM) from the STS Short-Term Risk Calculator. Logistic regression analysis was performed to evaluate additional perioperative variables contributing to death. Overall survival was 92.1% (569 of 597) at 1 year and 50.5% (164 of 325) at 7 years. Calibration assessment found no significant differences between predicted and actual survival curves for the overall sample or for the risk-stratified subgroups, whether stratified by predicted 7-year survival or by PROM. Discriminative performance was comparable between the ASCERT and PROM models for 7-year survival prediction (p validated for prediction of long-term survival after coronary artery bypass grafting in all risk groups. The widely used STS PROM performed comparably as a predictor of long-term survival. Both tools provide important information for preoperative decision making and patient counseling about potential outcomes after coronary artery bypass grafting. Copyright © 2018 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae [Yonsei University College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy.

  19. Transluminal endovascular stent-graft for the treatment of aortic aneurysms

    International Nuclear Information System (INIS)

    Lee, Do Yun; Chang, Byung Chul; Shim, Won Heum; Cho, Seung Yun; Chung, Nam Sik; Kwon, Hyuk Moon; Lee, Young Joon; Lee, Jong Tae

    1995-01-01

    The standard treatment for aortic aneurysms is surgical replacement with a prosthetic graft. Currently there is great interest in endoluminal intervention for treatment of aortic aneurysm. The purpose of this study was to evaluate the safety and effectiveness of endoluminally placed Stent-graft for the treatment of aortic aneurysms. Transluminal endovascular Stent-graft placements were attempted in 9 patients with infra-renal aortic aneurysms(n 6), thoracic aortic aneurysm(n = 1), and aortic dissection(n = 2). The endovascular Stent-grafts were custom-designed for each patient and were constructed of self-expandable modified Gianturco Stents covered with polytetrafluroethylene. The Stent-grafts were introduced through a 16-18 French sheath and expanded to 17-30 mm in diameter. The endovascular therapy was performed using a common femoral artery cutdown with local anesthesia. The endovascular Stent-graft deployment was achieved in 7 of 9 patients. Two cases failed deployment of the Stent-graft due to iliac artery stenosis and tortousity. There were complete thrombosis of the thoracic and infra-renal aortic aneurysm surround the Stent-graft in 3 patients, and persistent leak with partial thrombosis in 2. Two patients with aortic dissection were successfully treated by obliteration of entry tears. There were no major complication associated with Stent-graft placement. These preliminary results show that transluminal endovascular Stent-grafts offer great promise and good results. Further investigation is needed to establish its long-term safety and efficacy

  20. Guillain–Barré Syndrome after Coronary Artery Bypass Graft Surgery:a Case Report

    Directory of Open Access Journals (Sweden)

    Manouchehr Hekmat

    2016-01-01

    Full Text Available Guillain-Barre syndrome is a neurologic disorder that may appear after infection or major surgery.  Guillian-Barre syndrome following cardiac surgery is rare and only based on case reports, and we review all of the published cases. A 52-year-old man after 5 months suffering from chest pain was referred to our hospital and underwent coronary artery bypass graft for 3 vessel disease. The patient was discharged without complication on the 5th postoperative day. He presented Guillain- Barre syndrome after 12 months. He has not completely recovered weakness of upper extremities grade 4/5 with atrophy of both upper extremities remains after 18 months. This disorder is similar to classic GBS. It is important to be alert to de novo autoimmune neurological disorders after cardiac surgery. These disorders are similar to classic autoimmune disease and treated with standard therapies.

  1. Radial artery pulse waveform analysis based on curve fitting using discrete Fourier series.

    Science.gov (United States)

    Jiang, Zhixing; Zhang, David; Lu, Guangming

    2018-04-19

    Radial artery pulse diagnosis has been playing an important role in traditional Chinese medicine (TCM). For its non-invasion and convenience, the pulse diagnosis has great significance in diseases analysis of modern medicine. The practitioners sense the pulse waveforms in patients' wrist to make diagnoses based on their non-objective personal experience. With the researches of pulse acquisition platforms and computerized analysis methods, the objective study on pulse diagnosis can help the TCM to keep up with the development of modern medicine. In this paper, we propose a new method to extract feature from pulse waveform based on discrete Fourier series (DFS). It regards the waveform as one kind of signal that consists of a series of sub-components represented by sine and cosine (SC) signals with different frequencies and amplitudes. After the pulse signals are collected and preprocessed, we fit the average waveform for each sample using discrete Fourier series by least squares. The feature vector is comprised by the coefficients of discrete Fourier series function. Compared with the fitting method using Gaussian mixture function, the fitting errors of proposed method are smaller, which indicate that our method can represent the original signal better. The classification performance of proposed feature is superior to the other features extracted from waveform, liking auto-regression model and Gaussian mixture model. The coefficients of optimized DFS function, who is used to fit the arterial pressure waveforms, can obtain better performance in modeling the waveforms and holds more potential information for distinguishing different psychological states. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. Compliance Study of Endovascular Stent Grafts Incorporated with Polyester and Polyurethane Graft Materials in both Stented and Unstented Zones

    Directory of Open Access Journals (Sweden)

    Ying Guan

    2016-08-01

    Full Text Available Compliance mismatch between stent graft and host artery may induce complications and blood flow disorders. However, few studies have been reported on stent graft compliance. This study aims to explore the deformation and compliance of stent graft in stented and unstented zones under three pressure ranges. Compliance of two stent grafts incorporated with polyurethane graft (nitinol-PU and polyester graft (nitinol-PET materials respectively were tested; the stents used in the two stent grafts were identical. For the circumferential deformation of the stent grafts under each pressure range, the nitinol-PET stent graft was uniform in both zones. The nitinol-PU stent graft was circumferentially uniform in the stented zone, however, it was nonuniform in the unstented zone. The compliance of the PU graft material was 15 times higher than that of the PET graft. No significant difference in compliance was observed between stented and unstented zones of the nitinol-PET stent graft regardless of the applied pressure range. However, for the nitinol-PU stent graft, compliance of the unstented PU region was approximately twice that of the stented region; thus, compliance along the length of the nitinol-PU stent graft was not constant and different from that of the nitinol-PET stent graft.

  3. Comparing the Effect of Continuous and Intermittent Irrigation Techniques on Complications of Arterial Catheter and Partial Thromboplastin Time in Patients Following Coronary Artery Bypass Grafting Surgery

    Directory of Open Access Journals (Sweden)

    Sedigheh Arta

    2017-04-01

    Full Text Available Background: Different approaches are available to irrigate the arterial catheter, such as continuous and intermittent techniques. However, there is a disagreement regarding the most appropriate method. Aim: this study aimed to compare the effect of two continuous and intermittent irrigation methods on complications of arterial catheter and partial thromboplastin time (PTT in patients with coronary artery bypass (CABG surgery. Method: This randomized clinical trial was conducted on 60 participants undergoing coronary artery bypass grafting surgery in open-heart surgery ICU at Imam Reza hospital in Mashhad, Iran, in 2016. In continuous group, the arterial catheter was continuously irrigated with heparin solution at the rate of 2cc/h, and in the intermittent group with a syringe containing 5cc heparin solution every 3 hours. In both groups, catheter was monitored and recorded every 3 hours (until 48 hours and 3 times from enrollment in terms of complications of partial thromboplastin time. Data were analyzed using SPSS version 16. Results: The findingsof independent t-test showed that the two groups are homogeneous in age (P =0.48. The result of Fisher's exact test revealed no significant difference between the two groups in terms of average incidence of complications during the first 24 hours (P=0.55 and second 24 hours (P=0.55 after catheterization. Also during the 48 hours after surgery, independent t-test results showed no statistically significant difference in partial thromboplastin time (P=0.53 between the two groups. Implications for Practice: According to the results of the research based on the lack of difference between continuous and intermittent irrigation methods up to 48 hours after catheter replacement in terms of arterial catheter complications, further long-term follow-up researches are recommended.

  4. Magnetic resonance angiography in renal grafts. Comparison with color Doppler echography

    International Nuclear Information System (INIS)

    Yanagisawa, Takayoshi; Otsubo, Osamu; Nozaki, Harushige

    1995-01-01

    We studied relationship between magnetic resonance angiography (MRA) of renal graft and renal graft function in 14 renal transplantations (10 from living donors, 4 from cadaveric donors). MRA was performed on 0.3-T permanent magnet system (MRP 7000, HITACHI, JAPAN) using 2 dimensional time of flight technique (FOV: 350 mm 2 , RT: 60 msec, ET: 10 msec, FA: 90deg, Slice: volumes 60, thickness 4 mm, overlap 1 mm). As for parameters of renal graft function, we evaluated color doppler echography (CD) of transplanted renal artery, renal blood flow (RBF), velocity of interlobar artery (ILA) and serum creatinine level (S-Cr). CD, RBF and velocity of ILA were visualized and measured by duplex color doppler echosystem (EUB-565A, HITACHI, JAPAN). Depending on visualization of transplanted renal artery, MRA was graded into 3 groups (MA Grade 3: visualization of ILA, MA Grade 2: visualization of segmental artery and the first branch but no visualization of ILA, MA Grade 1: visualization of main renal artery only). Likewise, visualization of CD was graded into 3 groups (CD Grade 3: good visualization of arcuate artery (AA) and ILA, CD Grade 2: poor visualization of AA but good visualization of ILA, CD Grade 1: poor visualization of ILA). The MRA grading had a very significant correlation (r=0.79, p<0.001) with the CD grading. As for RBF and velocity of ILA, the RBF of MA Grade 3 group (n=8) was significantly (p<0.05) higher than the MA Grade 2 group (n=4) and the MA Grade 1 group (n=2), and the velocity of ILA of MA Grade 3 group was also higher than the above groups but not significantly. Furthermore, the S-Cr of MA Grade 3 was significantly (p<0.05) lower than the others. These results showed that MRA of renal graft had a qualitative index of renal graft function. (author)

  5. The new technique of using the epigastric arteries in renal transplantation with multiple renal arteries

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Amirzargar

    2013-01-01

    Full Text Available The most common anatomic variant seen in the donor kidneys for renal transplantation is multiple renal arteries (MRA, which can cause an increased risk of complications. We describe the long-term outcomes of 16 years of experience in 76 kidney transplantations with MRAs. In a new reconstruction technique, we remove arterial clamps after anastomosing the donor to the recipient′s main renal vessels, which cause backflow from accessory arteries to prevent thrombosis. By this technique, we reduce the ischemic times as well as the operating times. Both in live or cadaver donor kidneys, lower polar arteries were anastomosed to the inferior epigastric artery and upper polar arteries were anastomosed to the superior epigastric arteries. Injection of Papaverine and ablation of sympathic nerves of these arteries dilate and prevent them from post-operative spasm. Follow-up DTPA renal scan in all patients showed good perfusion and function of the transplanted kidney, except two cases of polar arterial thrombosis. Mean creatinine levels during at least two years of follow-up remained acceptable. Patient and graft survival were excellent. No cases of ATN, hypertension, rejection and urologic complications were found. In conclusion, this technique can be safely and successfully utilized for renal transplantation with kidneys having MRAs, and may be associated with a lower complication rate and better graft function compared with the existing techniques.

  6. Percutaneous Endoluminal Stent-Graft Repair of an Old Traumatic Femoral Arteriovenous Fistula

    International Nuclear Information System (INIS)

    Uflacker, Renan; Elliott, Bruce M.

    1996-01-01

    A stent-graft was custom made to close a high-flow traumatic arteriovenous fistula of the left superficial femoral artery, present for 30 years, in a 60-year-old man with congestive heart failure and ischemic ulceration in the left foot. A balloon expandable Palmaz stent (P394; 2.5 mm x 3.9 cm) was covered with a polytetrafluoroethylene (PTFE) graft and was inserted percutaneously through an 11 Fr vascular sheath. Follow-up Doppler ultrasound at 6 months demonstrated occlusion of the arteriovenous fistula, patency of the artery, and luminal integrity of the artery and vein

  7. Free radial forearm flap versatility for the head and neck and lower extremity

    International Nuclear Information System (INIS)

    Chicarilli, Z.N.; Ariyan, S.; Cuono, C.B.

    1986-01-01

    Microsurgical techniques have developed numerous territories suitable for free tissue transfer. However, the demand for thin cutaneous resurfacing limits the choice of flaps available to the reconstructive microsurgeon. The radial forearm flap is a thin, axial, fasciocutaneous flap, offering pliable cutaneous resurfacing, with or without sensation. We have used 15 flaps to reconstruct defects in the head and neck and lower extremity resulting from burns, blunt and avulsive trauma, radiation necrosis, and tumor ablation. Two flaps (15 percent) developed venous congestion and were salvaged by reoperation. One retrograde flap (7.5 percent) developed partial necrosis from arterial insufficiency. Neural re-innervation was successful in two out of three patients in whom it was attempted. Two patients (15%) sustained minor donor site skin graft loss that healed secondarily. In our series of predominantly older patients the donor sites have been relatively inconspicuous at one year follow-up. A functional restoration was achieved in all patients

  8. Treatment of pseudoaneurysms with stent-graft: preliminary experience in 12 cases

    International Nuclear Information System (INIS)

    Liao Denghui; Ye Caisheng; Li Songqi; Ye Runyi; Chang Guangqi; Chen Wei; Li Xiaoxi; Wang Shenming

    2012-01-01

    Objective: To asses the clinical effect of stent-graft in the treatment of pseudoaneurysms. Methods: During the period from March 2008 to June 2011, 86 patients with pseudoaneurysms were admitted to the hospital, of whom stent-graft implantation was carried out in 12. The pseudoaneurysms were located at the thoracic aorta (n=4), abdominal aorta (n=3), common carotid artery (n=3), internal carotid artery (n=1) and right subclavian artery (n=1). All the patient were followed up for 5-43 months. The clinical results were analyzed. Results: The technical success rate for stent delivery was 100%. The pseudoaneurysms was immediately isolated after the procedure in all 12 cases. After endovascular exclusion with stent-graft, no leakage occurred and the blood flow distal to the parent artery was normal. All patients were followed up for a mean period of 23.5 months except one who lost in touch with the authors. One patient with coexisting Behcet's disease died of massive bleeding due to abdominal aortic rupture four months after operation. The other patients were in good clinical condition, and no complications such as stent stenosis, displacement, internal leakage etc. were observed in the follow-up period. Conclusion: The implantation of stent-graft has satisfactory short-term effect in treating pseudoaneurysms, although its long-term efficacy needs to be further observed. (authors)

  9. Pleurotomy with subxyphoid pleural drain affords similar effects to pleural integrity in pulmonary function after off-pump coronary artery bypass graft

    OpenAIRE

    Guizilini, Solange; Bolzan, Douglas W; Faresin, Sonia M; Ferraz, Raquel F; Tavolaro, Kelly; Cancio, Andrea A; Gomes, Walter J

    2012-01-01

    Abstract Background Exacerbation of pulmonary dysfunction has been reported in patients receiving a pleural drain inserted through the intercostal space in comparison to patients with an intact pleura undergoing coronary artery bypass grafting (CABG). Evidence suggests that shifting the site of pleural drain insertion to the subxyphoid position minimizes chest wall trauma and preserves respiratory function in the early postoperative period. The aim of this study was to compare the pulmonary f...

  10. Non-gated vessel wall imaging of the internal carotid artery using radial scanning and fast spin echo sequence. Evaluation of vessel signal intensity by flow rate at 3.0 tesla

    International Nuclear Information System (INIS)

    Nakamura, Manami; Makabe, Takeshi; Ichikawa, Masaki; Hatakeyama, Ryohei; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-01-01

    Vessel wall imaging using radial scanning does not use a blood flow suppression pulse with gated acquisition. It has been proposed that there may not be a flow void effect if the flow rate is slow; however, this has yet to be empirically tested. To clarify the relationship between the signal intensity of the vessel lumen and the blood flow rate in a flow phantom, we investigated the usefulness of vessel wall imaging at 3.0 tesla (T). We measured the signal intensity while changing the flow rate in the flow phantom. Radial scanning at 1.5 T showed sufficient flow voids at above medium flow rates. There was no significant difference in lumen signal intensity at the carotid artery flow rate. The signal intensity of the vessel lumen decreased sufficiently using the radial scan method at 3.0 T. We thus obtained sufficient flow void effects at the carotid artery flow rate. We conclude this technique to be useful for evaluating plaque if high contrast can be maintained for fixed tissue (such as plaque) and the vessel lumen. (author)

  11. Spinal anesthesia reduces postoperative delirium in opium dependent patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Tabatabaie, O; Matin, N; Heidari, A; Tabatabaie, A; Hadaegh, A; Yazdanynejad, S; Tabatabaie, K

    2015-01-01

    We investigated the effect of high spinal anesthesia on postoperative delirium in opium dependent patients undergoing coronary artery bypass grafting (CABG). The study was conducted in a tertiary referral university hospital on a population of 60 opium dependent patients undergoing CABG surgery. Patients were divided into two groups based on anesthesia protocol. One group were given general anesthesia (GA Group), the other group additionally received intrathecal morphine and bupivacaine (SGA Group). Postoperative delirium (POD) was defined as the main outcome of interest. Incidence of POD was significantly higher in patients of GA Group as compared with those in SGA Group (47% and 17% for GA and SGA respectively; P-value = 0.01). Time to extubation was on average 2.2 h shorter in SGA than in GA (7.1 h and 9.3 h respectively, P-value opium dependent patients.

  12. Composite vascular grafts with high cell infiltration by co-electrospinning

    International Nuclear Information System (INIS)

    Tan, Zhikai; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-01-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  13. Composite vascular grafts with high cell infiltration by co-electrospinning

    Energy Technology Data Exchange (ETDEWEB)

    Tan, Zhikai, E-mail: tanzk@hnu.edu.cn; Wang, Hongjie; Gao, Xiangkai; Liu, Tong; Tan, Yongjun

    2016-10-01

    There is an increasing demand for functional small-diameter vascular grafts (diameter < 6 mm) to be used in clinical arterial replacement. An ideal vascular graft should have appropriate biomechanical properties and be biocompatible. Electrospinning has become a popular polymer processing technique for vascular tissue engineering, but the grafts fabricated by electrospinning often have relatively small pores and low porosity, which limit cell infiltration into scaffolds and hinder the regeneration and remodeling of grafts. In the present study, we aimed to develop an efficient method to prepare electrospun composite vascular grafts comprising natural and synthetic materials. We fabricated grafts made of polycaprolactone, gelatin, and polyvinyl alcohol (PVA) by co-electrospinning, and the scaffolds were further functionalized by immobilizing heparin on them. The PVA fibers degraded rapidly in vivo and generated electrospun scaffolds with high porosity, which significantly enhanced cell proliferation and infiltration. The mechanical properties of the grafts are suitable for use in artery replacement. Heparin functionalization of the grafts yielded a good antithrombogenic effect, which was demonstrated in platelet adhesion tests. Moreover, in vitro and in vivo results demonstrated that the heparin release from the grafts enhanced the growth of endothelial cells, which is important for the endothelium of implanted grafts. The results of this study indicate that our method is effective and controllable for the fabrication of vascular grafts that meet the clinical requirements for blood vessel transplantation. - Highlights: • This study indicate an effective method for the fabrication of vascular grafts that meet the clinical requirements. • Co-electrospinning were used to fabricate grafts made of polycaprolactone (PCL), gelatin (GT), and polyvinyl alcohol (PVA). • PVA was used to create large pores within the hybrid scaffolds, thereby enhancing cell infiltration

  14. Intra-myocardial LAD: Is it a contraindication for off-pump coronary artery bypass grafting?

    Directory of Open Access Journals (Sweden)

    Ashraf Fawzy Mahmoud

    2018-03-01

    Full Text Available Background: The left anterior descending artery (LAD is the most important vessel in coronary artery bypass graft surgery (CABG. During CABG, LAD may be intra-myocardial for variable distances and depths. This forms a challenge during LAD exposure and anastomosis.The aim was to revise the performed CABG cases to elicit what was the incidence of intramyocardial LAD (IMLAD among all CABGs, to have an idea about the approaches to the IMLAD and the technique of anastomosis of left internal mammary artery (LIMA to IMLAD off-pump (OPCAB and to evaluate the validity and reliability of the off-pump for the IMLAD. Methods: Since September 2008 till May 2017; the data of 1138 Off-Pump CABGs were revised. 923 patients had epicardial LAD and it was visible and easily identified throughout 80% of its length; this was group A. 215 (18.89% patients had IMLAD; they were referred to as group B. Results: There were no statistical significant differences between both groups as regards the age, the sex, the risk factors or the duration of surgery. The post operative bleeding, ischemia, CCU stay and hospital stay were not statistically significant. Conversion to on-pump for the mere presence of an intramyocardial LAD was zero%, but it was 1.3% in group A and 1.86% in B due to hemodynamic instability during manipulations (statistically insignificant. Conclusions: The incidence of IMLAD was 18.89%. IMLAD was a real technical challenge. It was not impossible for exposure and anastomosisas off-pump. The IMLAD is not a contraindication for OPCAB. Keywords: IMLAD, OPCAB, LIMA/LAD

  15. Perioperative management of a patient with Glanzmann thrombasthenia undergoing a coronary artery bypass graft surgery: a case report.

    Science.gov (United States)

    Kurdi, Mohamad; Frère, Corinne; Amour, Julien; Brumpt, Caren; Delort, Josée; Lebreton, Guillaume; Croisille, Laure; d'Oiron, Roseline; Martin-Toutain, Isabelle

    2018-04-01

    : We report herein the successful perioperative management of a 57-year-old man with a type I Glanzmann thrombasthenia undergoing coronary artery bypass graft surgery and right carotid endarterectomy. The patient suffered from several lesions in the three major coronary arteries and in the right carotid necessitating surgery. Prophylactic human leukocyte antigen (HLA)-matched platelets transfusions were continuous administrated before, and through the immediate perioperative period. Posttransfusion platelet recovery was monitored using flow cytometry to determine the percentage of circulating platelet expressing CD61 (β3). No bleeding complications occurred during and following the procedure. The patient did not develop HLA antibodies or αIIbβ3 antibodies. Thrombophilia screening revealed a heterozygous G20210A prothrombin gene mutation. The patient also suffered from an atrial fibrillation, necessitating anticoagulation therapy. During the hospital stay, a treatment with vitamin K antagonists for stroke prevention was initiated. The patient was discharged 8 days following surgery, and no further complications occurred during the 6 months follow-up.

  16. Gender-linked impact of epicardial adipose tissue volume in patients who underwent coronary artery bypass graft surgery or non-coronary valve surgery

    OpenAIRE

    Maimaituxun, Gulinu; Shimabukuro, Michio; Salim, Hotimah Masdan; Tabata, Minoru; Yuji, Daisuke; Morimoto, Yoshihisa; Akasaka, Takeshi; Matsuura, Tomomi; Yagi, Shusuke; Fukuda, Daiju; Yamada, Hirotsugu; Soeki, Takeshi; Sugimoto, Takaki; Tanaka, Masashi; Takanashi, Shuichiro

    2017-01-01

    Background Traditional and non-traditional risk factors for atherosclerotic cardiovascular disease (ASCVD) are different between men and women. Gender-linked impact of epicardial adipose tissue volume (EATV) in patients undergoing coronary artery bypass grafting (CABG) remains unknown. Methods Gender-linked impact of EATV, abdominal fat distribution and other traditional ASCVD risk factors were compared in 172 patients (men: 115; women: 57) who underwent CABG or non-coronary valvular surgery ...

  17. Investigation of occupational radiation exposure during interventional cardiac catheterizations performed via radial artery

    International Nuclear Information System (INIS)

    Goni, H.; Papadopoulou, D.; Yakoumakis, Em; Stratigis, N.; Benos, J.; Siriopoulou, V.; Makri, Tr; Georgiou, Ev

    2005-01-01

    The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angio-plasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterizations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm 2 for each procedure. Staff radiation doses varied between 34 and 235 μGy per procedure at the left wrist, 28 and 172 μGy at the right wrist, 16 and 106 μGy at the level of the thyroid and 16 and 154 μGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm 2 . Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs. (authors)

  18. Evaluation of olfactory memory after coronary artery bypass grafting.

    Science.gov (United States)

    Erdem, Kemalettin; Yurttas, Veysel; Bilgi, Murat; Demırhan, Abdullah; Apuhan, Tayfun; Bugra, Onursal; Daglar, Bahadir

    2014-12-01

    This study determined whether coronary artery bypass grafting (CABG) surgery has any effect on olfactory function, employing the Brief Smell Identification Test (B-SIT). All the participants were informed preoperatively about the B-SIT test and the mode of its application. The test was performed by each patient preoperatively (d0) as well as 1 (d1) and 3 (d3) days following the surgery. C-reactive protein (CRP) levels were recorded at the same time as the smell test. This prospective study included 45 patients. The mean age was 67 ± 7.55, and the group was 29% male. The mean durations of cross clamping and cardiopulmonary bypass were 54 ± 32 min and 62.5 ± 37.0 min, respectively. Eleven different odors were tested. Significant differences were observed for several odors: leather between d0 and d3, pine between d0 and d3, onion between d0 and d1, onion between d0 and d3, and soap between d0 and d1. The postoperative CRP levels were significantly higher than the preoperative levels. The correlation analysis determined that the postoperative CRP levels were negatively correlated with the B-SIT score (r = -0.48, p = 0.001). Our findings suggest that patients after CABG are prone to develop olfactory dysfunction in the early postoperative period and that olfactory dysfunction is associated with postoperative CRP levels.

  19. How Older Female Spouses Cope with Partners’ Coronary Artery Bypass Graft Surgery

    Directory of Open Access Journals (Sweden)

    Suzanne Marnocha

    2013-01-01

    Full Text Available This research sought to better understand how older female spouses cope with a partner’s coronary artery bypass graft surgery and to explore coping’s relationships with life-change stress, cognitive appraisal, resilience, social support, and aspects of spouse’s surgery. A sample of 96 women, aged from 55 to 81 years, completed surveys after their partner’s surgery. Folkman and Lazarus’ ways of coping (WCQ scales yielded two factors in this sample—reactive coping and adaptive coping. Reactive coping, including more emotion-focused ways of coping from the WCQ, was associated only with more time spent anticipating spouses’ surgeries. Women described the greatest use of ways of coping labeled adaptive, which in turn had significant relationships with greater resilience, social support, and positive appraisal of the surgical experience. Stepwise multiple regression found greater resilience, more frequent religious participation, and fewer children to be distinct predictors of adaptive coping. Nursing staff are encouraged to accept and normalize reactive coping, while facilitating adaptive coping with surgical stresses.

  20. On the relationship between competitive flow and FFT analysis of the flow waves in the left internal mammary artery graft in the process of CABG.

    Science.gov (United States)

    Mao, Boyan; Wang, Wenxin; Zhao, Zhou; Zhao, Xi; Li, Lanlan; Zhang, Huixia; Liu, Youjun

    2016-12-28

    During coronary artery bypass grafting (CABG), the ratio of powers of the fundamental frequency and its first harmonic (F0/H1) in fast Fourier transformation (FFT) analysis of the graft's flow waves has been used in the field of evaluation of the patency in anastomosis. But there is no report about using the FFT method to evaluate the magnitude of competitive flow. This study is aiming at exploring the relationship between competitive flow and FFT analysis of the flow waves in left internal mammary artery (LIMA) graft, and finding a new method to evaluate the magnitude of competitive flow. At first, establishing the CABG multiscale models of different stenosis in left anterior descending artery (LAD) to get different magnitude of competitive flows. Then, calculating the models by ANSYS-CFX and getting the flow waves in LIMA. Finally, analyzing the flow waves by FFT method and comparing the FFT results with the magnitude of competitive flow. There is no relationship between competitive flow and F0/H1. As for F0/H2 and F0/H3, they both increase with the reduction of the stenosis in LAD. But the increase of F0/H3 is not obviously enough and it can't identify the significant competitive flow clearly, so it can't be used as the evaluation index. It is found that F0/H2 increases obviously with the increase of the competitive flow and can identify the significant competitive flow. The FFT method can be used in the evaluation of competitive flow and the F0/H2 is the ideal index. High F0/H2 refers to the significant competitive flow. This method can be used during CABG to avoid the risk of competitive flow.

  1. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  2. Tuning the Mechanical Properties of Polymer Nanocomposites Filled with Grafted Nanoparticles by Varying the Grafted Chain Length and Flexibility

    Directory of Open Access Journals (Sweden)

    Zixuan Wang

    2016-08-01

    Full Text Available By employing coarse-grained molecular dynamics simulation, we simulate the spatial organization of the polymer-grafted nanoparticles (NPs in homopolymer matrix and the resulting mechanical performance, by particularly regulating the grafted chain length and flexibility. The morphologies ranging from the agglomerate, cylinder, sheet, and string to full dispersion are observed, by gradually increasing the grafted chain length. The radial distribution function and the total interaction energy between NPs are calculated. Meanwhile, the stress–strain behavior of each morphology and the morphological evolution during the uniaxial tension are simulated. In particular, the sheet structure exhibits the best mechanical reinforcement compared to other morphologies. In addition, the change of the grafted chain flexibility to semi-flexibility leads to the variation of the morphology. We also find that at long grafted chain length, the stress–strain behavior of the system with the semi-flexible grafted chain begins to exceed that of the system with the flexible grafted chain, attributed to the physical inter-locking interaction between the matrix and grafted polymer chains. A similar transition trend is as well found in the presence of the interfacial chemical couplings between grafted and matrix polymer chains. In general, this work is expected to help to design and fabricate high performance polymer nanocomposites filled with grafted NPs with excellent and controllable mechanical properties.

  3. The effect of nitric oxide synthase inhibition on histamine induced headache and arterial dilatation in migraineurs

    DEFF Research Database (Denmark)

    Lassen, L H; Christiansen, I; Iversen, Helle Klingenberg

    2003-01-01

    -decrease in MCA blood velocity, or dilatation of neither the temporal nor the radial artery. L-NMMA constricted the temporal artery by 8% before histamine infusion, whereas the radial artery was unaffected. The temporal artery dilated 4-5 times more than the radial artery during histamine infusion. In conclusion...... the use of a NOS inhibitor in the highest possible dose did not block the histamine-induced headache response or arterial dilatation. Either the concentration of L-NMMA reaching the smooth muscle cell was insufficient or, histamine dilates arteries and causes headache via NO independent mechanisms. Our...... results showed for the first time a craniospecificity for the vasodilating effect of histamine and for the arterial effects of NOS inhibition....

  4. Results of completion arteriography after minimally invasive off-pump coronary artery bypass.

    Science.gov (United States)

    Hoff, Steven J; Ball, Stephen K; Leacche, Marzia; Solenkova, Natalia; Umakanthan, Ramanan; Petracek, Michael R; Ahmad, Rashid; Greelish, James P; Walker, Kristie; Byrne, John G

    2011-01-01

    The benefits of a minimally invasive approach to off-pump coronary artery bypass remain controversial. The value of completion arteriography in validating this technique has not been investigated. From April 2007 to October 2009, fifty-six patients underwent isolated minimally invasive coronary artery bypass grafting through a left thoracotomy without cardiopulmonary bypass. Forty-three of these patients underwent completion arteriography. Sixty-five grafts were performed in these 56 patients, (average, 1.2 grafts per patient; range, 1 to 3). Forty-eight grafts were studied in the 43 patients undergoing completion arteriography. There were 4 findings on arteriogram leading to further immediate intervention (8.3%). These included 3 grafts with anastomotic stenoses or spasm requiring stent placement, and 1 patient who had limited dissection in the left internal mammary artery graft and underwent placement of an additional vein graft. These findings were independent of electrocardiographic changes or hemodynamic instability. The remainder of the studies showed no significant abnormalities. There were no deaths. One patient who did not have a completion arteriogram suffered a postoperative myocardial infarction requiring stent placement for anastomotic stenosis. Patients were discharged home an average of 6.8 days postoperatively. There were no instances of renal dysfunction postoperatively attributable to catheterization. Minimally invasive coronary artery bypass is safe and effective. Findings of completion arteriography occasionally reveal previously under-recognized findings that, if corrected in a timely fashion, could potentially impact graft patency and clinical outcomes. Our experience validates this minimally invasive technique. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Identifying factors that predict the choice and success rate of radial artery catheterisation in contemporary real world cardiology practice: a sub-analysis of the PREVAIL study data.

    Science.gov (United States)

    Pristipino, Christian; Roncella, Adriana; Trani, Carlo; Nazzaro, Marco S; Berni, Andrea; Di Sciascio, Germano; Sciahbasi, Alessandro; Musarò, Salvatore Donato; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio

    2010-06-01

    To assess: the reasons behind an operator choosing to perform radial artery catheterisation (RAC) as against femoral arterial catheterisation, and to explore why RAC may fail in the real world. A pre-determined analysis of PREVAIL study database was performed. Relevant data were collected in a prospective, observational survey of 1,052 consecutive patients undergoing invasive cardiovascular procedures at nine Italian hospitals over a one month observation period. By multivariate analysis, the independent predictors of RAC choice were having the procedure performed: (1) at a high procedural volume centre; and (2) by an operator who performs a high volume of radial procedures; clinical variables played no statistically significant role. RAC failure was predicted independently by (1) a lower operator propensity to use RAC; and (2) the presence of obstructive peripheral artery disease. A 10-fold lower rate of RAC failure was observed among operators who perform RAC for > 85% of their personal caseload than among those who use RAC < 25% of the time (3.8% vs. 33.0%, respectively); by receiver operator characteristic (ROC) analysis, no threshold value for operator RAC volume predicted RAC failure. A routine RAC in all-comers is superior to a selective strategy in terms of feasibility and success rate.

  6. Cost-Effectiveness Evaluation of Heparin Coated Versus Standard Graft for Bypass Surgery in Peripheral Artery Disease Alongside a Randomised Controlled Trial

    DEFF Research Database (Denmark)

    Villemoes, Marie K; Lindholt, Jes S; Houlind, Kim C

    2018-01-01

    as arithmetic means with bootstrapped 95% confidence intervals. Cost-effectiveness acceptability curves were used to illustrate the probability of cost-effectiveness for a range of threshold values of willingness to pay (WTP). RESULTS: No statistically significant differences between the randomisation groups...... were observed for costs or gains of LYs or QALYs. The average cost per QALY was estimated at €10,792. For a WTP threshold of €40,000 per QALY, the overall probability of cost-effectiveness was estimated at 62%, but owing to cost savings in patients with critical ischaemia (cost per QALY ...OBJECTIVE/BACKGROUND: Heparin coating has recently been shown to reduce the risk of graft failure in arterial revascularisation, at least transiently. The aim of this study was to assess the cost-effectiveness of heparin coated versus standard polytetrafluoroethylene grafts for bypass surgery...

  7. Percutaneous treatment of complications occurring during hemodialysis graft recanalization

    Energy Technology Data Exchange (ETDEWEB)

    Sofocleous, Constantinos T. E-mail: constant@pol.net; Schur, Israel; Koh, Elsie; Hinrichs, Clay; Cooper, Stanley G.; Welber, Adam; Brountzos, Elias; Kelekis, Dimitris

    2003-09-01

    Introduction/objective: To describe and evaluate percutaneous treatment methods of complications occurring during recanalization of thrombosed hemodialysis access grafts. Methods and materials: A retrospective review of 579 thrombosed hemodialysis access grafts revealed 48 complications occurring during urokinase thrombolysis (512) or mechanical thrombectomy (67). These include 12 venous or venous anastomotic ruptures not controlled by balloon tamponade, eight arterial emboli, 12 graft extravasations, seven small hematomas, four intragraft pseudointimal 'dissections', two incidents of pulmonary edema, one episode of intestinal angina, one procedural death, and one distant hematoma. Results: Twelve cases of post angioplasty ruptures were treated with uncovered stents of which 10 resulted in graft salvage allowing successful hemodialysis. All arterial emboli were retrieved by Fogarty or embolectomy balloons. The 10/12 graft extravasations were successfully treated by digital compression while the procedure was completed and the graft flow was restored. Dissections were treated with prolonged Percutaneous Trasluminal Angioplasty (PTA) balloon inflation. Overall technical success was 39/48 (81%). Kaplan-Meier Primary and secondary patency rates were 72 and 78% at 30, 62 and 73% at 90 and 36 and 67% at 180 days, respectively. Secondary patency rates remained over 50% at 1 year. There were no additional complications caused by these maneuvers. Discussions and conclusion: The majority of complications occurring during percutaneous thrombolysis/thrombectomy of thrombosed access grafts, can be treated at the same sitting allowing completion of the recanalization procedure and usage of the same access for hemodialysis.

  8. Treatment of splenic artery aneurysm with double overlapping bare stents: case report

    International Nuclear Information System (INIS)

    Kwak, Hyo Sung; Han, Young Min; Jin, Gong Yong

    2004-01-01

    The traditional treatment of splenic artery aneurysm (SAA) is generally surgery and/or transcatheter arterial embolization, but recently, the treatment of SAA using a stent graft has been reported. However, the acute angle of the celiac axis, as well as the tortuous path of the splenic artery makes the use of stent graft difficult for treatment of aneurysma. We report here a case of SAA treated with the technique of double overlapping metallic stents

  9. Percutaneous coronary intervention versus coronary artery bypass grafting: where are we after NOBLE and EXCEL?

    Science.gov (United States)

    Fortier, Jacqueline H; Shaw, Richard E; Glineur, David; Grau, Juan B

    2017-11-01

    The publication of the NOBLE and EXCEL trials, with seemingly conflicting results, brought into question whether percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) is better for low-risk patients with left main coronary artery stenosis (LMCAS). This review appraises the methods and results of NOBLE and EXCEL, contextualizes them within the literature, and determines how they may affect clinical practice. We appraised the trials and describe differences in methodology and results. NOBLE recruited primarily isolated LMCAS, and found that CABG was superior to PCI. EXCEL's population included patients LMCAS in the context of multivessel CAD, and found PCI and CABG were comparable. Both trials enrolled young patients with few comorbidities, and there was more protocol-mandated consistency in the procedural techniques and medical therapy of patients receiving PCI. The generalizability of these trials is limited by the use of young, healthy patients at highly skilled centres that rarely reflect typical clinical practice. If these studies are to maintain relevance, trialists must address the lack of protocolization of surgical interventions and inconsistent medical therapies. Unfortunately, the limitations of NOBLE and EXCEL mean that we are no closer to answering the question of what is the optimal treatment for patients with LMCAS.

  10. Sympathetic Innervation Promotes Arterial Fate by Enhancing Endothelial ERK Activity.

    Science.gov (United States)

    Pardanaud, Luc; Pibouin-Fragner, Laurence; Dubrac, Alexandre; Mathivet, Thomas; English, Isabel; Brunet, Isabelle; Simons, Michael; Eichmann, Anne

    2016-08-19

    Arterial endothelial cells are morphologically, functionally, and molecularly distinct from those found in veins and lymphatic vessels. How arterial fate is acquired during development and maintained in adult vessels is incompletely understood. We set out to identify factors that promote arterial endothelial cell fate in vivo. We developed a functional assay, allowing us to monitor and manipulate arterial fate in vivo, using arteries isolated from quails that are grafted into the coelom of chick embryos. Endothelial cells migrate out from the grafted artery, and their colonization of host arteries and veins is quantified. Here we show that sympathetic innervation promotes arterial endothelial cell fate in vivo. Removal of sympathetic nerves decreases arterial fate and leads to colonization of veins, whereas exposure to sympathetic nerves or norepinephrine imposes arterial fate. Mechanistically, sympathetic nerves increase endothelial ERK (extracellular signal-regulated kinase) activity via adrenergic α1 and α2 receptors. These findings show that sympathetic innervation promotes arterial endothelial fate and may lead to novel approaches to improve arterialization in human disease. © 2016 American Heart Association, Inc.

  11. A Segmental Hypoplastic Anterior Tibial Artery Coexisting with a Hypertrophied Perforating Fibular Artery a Case Report and Clinical Implications

    OpenAIRE

    Ariyo, Olutayo

    2015-01-01

    Vascular injuries of the lower limb, especially from penetrating gunshot wounds, and peripheral arterial diseases are on the increase and management of these and many other lower limb injuries involve increasing usage of vascular interventions like by-pass surgery, per-cutaneous transluminal angioplasty, arterial cannulation, arterial bypass graft or minimally invasive measures like percutaneous trans-arterial catheterization, among others. A thorough knowledge of infrapopliteal branching mos...

  12. Anomalous right coronary artery arising from the pulmonary artery and constrictive pericarditis: an unusual association

    Science.gov (United States)

    Silvestre, Odilson Marcos; Adam, Eduardo Leal; de Melo, Dirceu Thiago Pessoa; Dias, Ricardo Ribeiro; Ramires, Felix J. A.; Mady, Charles

    2013-01-01

    ABSTRACT The association of anomalous right coronary artery originating from the pulmonary artery and constrictive pericarditis has never been showed in the literature. We present the first case of this unusual association in a patient with right heart failure. After diagnosis, the patient was referred to surgery and underwent phrenic-to-phrenic pericardiectomy; graft implant of right internal thoracic artery to right coronary artery; and ligation of the anomalous origin of the right coronary artery from the pulmonary artery. Such procedures solved the potential risk of sudden death related to anomalous right coronary artery originating from the pulmonary artery and alleviated the symptoms of heart failure caused by constrictive pericarditis. PMID:24136766

  13. Intraoperative coronary grafts flow measurement using the TTFM flowmeter: results from a domestic sample.

    Science.gov (United States)

    Succi, José Ernesto; Gerola, Luis Roberto; Succi, Guilherme de Menezes; Kim, Hyong Chun; Paredes, Jorge Edwin Morocho; Bufollo, Enio

    2012-01-01

    To evaluate intraoperative graft patency and identify grafts under risk of early occlusion. Fifty four patients were submitted to coronary artery bypass surgery and the graft flow was assessed by the Flowmeter (Medtronic Medistim), which utilizes the TTFM method. Three patients had left main disease and 48 had normal or mildly reduced left ventricular function. In hospital mortality was 3.7% (two patients), one for mesenteric thrombosis and one due to cardiogenic chock. Seventeen patients (34%) were submitted to off pump CABG. Arterial Graft flow measures ranged from 8 to 106 ml/min (average 31.14 ml/min), and venous grafts flow ranged from 9 to 149 ml/min (average 50.42 ml/min). Flowmeter use represents higher safety both for patients and surgeons. Even under legal aspects, the documentation provided by the device can avoid future questionings.

  14. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    International Nuclear Information System (INIS)

    Youn, Sung Won; Kim, Ho Kyun; Do, Jin Kook; Kim, Young Whan

    2011-01-01

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  15. Self-Expandable Stenting over a Stent Graft for the Exclusion of a Carotid Stump: Troubleshooting for Device Incompatibility

    Energy Technology Data Exchange (ETDEWEB)

    Youn, Sung Won; Kim, Ho Kyun [Dept. of Radiology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Do, Jin Kook [Dept. of Neurology, Catholic University of Daegu School of Medicine, Daegu (Korea, Republic of); Kim, Young Whan [Dept. of Radiology, University College of Medicine, Daegu (Korea, Republic of)

    2011-12-15

    Carotid stump, the blind remnant of an occluded internal carotid artery, can be a potential source of microemboli, and warrants its exclusion from the vascular lumen to prevent the recurrence of a microembolism. In a 69-year-old male with a symptomatic carotid stump and acute angle between left common carotid artery and aortic arch, a 7-Fr. shuttle sheath was scarcely placed into the left carotid artery but the 7-mm-diameter stent-graft-loading balloon could not be inserted into the 7-Fr. shuttle sheath. With the mounting a stent graft over a 5-mm balloon, the balloon-expandable stent graft was unfolded. The self-expandable stent was placed over the stent graft, and an 8-mm balloon was subsequently expanded. Self-expanding stenting can be useful for troubleshooting in a case of device incompatibility coming from the different calibers of the external and common carotid arteries for the successful exclusion of a symptomatic carotid stump.

  16. Rule-based model of vein graft remodeling.

    Directory of Open Access Journals (Sweden)

    Minki Hwang

    Full Text Available When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC, extracellular matrix (ECM, and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.

  17. Distal Marginal Stenosis: A Contributing Factor in Delayed Carotid Occlusion of a Patient With Carotid Blowout Syndrome Treated With Stent Grafts

    Directory of Open Access Journals (Sweden)

    Feng-Chi Chang

    2010-05-01

    Full Text Available Distal marginal stenosis is rarely reported to be a factor associated with poor long-term patency of patients of head and neck cancers with carotid blowout syndrome treated with stent grafts. We report a case of laryngeal cancer with rupture of the right common carotid artery. A self-expandable stent graft was deployed, but bleeding recurred. Another stent graft was deployed for the pseudoaneurysm located distal to the first stent graft. Rebleeding occurred because of pseudoaneurysm formation from reconstituted branches of the right superior thyroid artery. We performed direct percutaneous puncture of the proximal superior thyroid artery for successful embolization. Distal marginal stenosis and asymptomatic thrombosis of the carotid artery were noted at 3.5- and 5-month follow-ups, respectively. We suggest aggressive early follow-up and reintervention for distal marginal stenosis by combined antibiotic therapy and angioplasty and stenting to improve the long-term patency of stent-graft deployment for management of carotid blowout syndrome.

  18. Nasolabial facial artery and vein as recipient vessels for midface microsurgical reconstruction.

    Science.gov (United States)

    Oh, Suk Joon; Jeon, Man Kyung; Koh, Sung Hoon

    2011-05-01

    Although free flap transfer is commonly performed to reconstruct facial defects, the submandibular facial artery and vein have historically been considered as adequate recipient vessels for microsurgical reconstruction. If the vascular pedicles of the free flap are short, vein grafts are necessary. The purpose of this study was to determine the indications for and effectiveness of using the nasolabial facial vessels for midfacial reconstruction. A retrospective chart review of 6 patients undergoing microsurgical reconstruction for defects of the face revealed 6 free tissue transfers in which the nasolabial facial artery and vein were considered for use as recipient vessels. Flap success rates were evaluated. Six patients (5 men and 1 woman) underwent 6 free flap transfers. Five anterior helix free flaps were used for the reconstruction of defects in the lower third of the nose. Nasal defects were due to trauma in 4 patients and squamous cell carcinoma in 1 patient. In 1 neurofibromatosis type 1 case, a radial forearm flap was used for reconstruction of the left orbital defect. The facial artery and vein in the nasolabial fold were used as the recipient artery and vein in every case. The mean length of follow-up was 5.8 years. All flaps survived. All patients were satisfied with the degree of aesthetic improvement after surgery.Use of the facial artery and vein in the nasolabial fold for facial reconstruction is reliable and safe. The nasolabial facial artery and vein should be considered as primary recipient vessels in microsurgical reconstruction of the midface.

  19. Superior Lower Extremity Vein Graft Bypass Patency among Married Patients with Peripheral Artery Disease.

    Science.gov (United States)

    Lagergren, Emily; Kempe, Kelly; Craven, Timothy E; Kornegay, Susan T; Hurie, Justin B; Garg, Nitin; Velazquez-Ramirez, Gabriela; Edwards, Matthew S; Corriere, Matthew A

    2017-10-01

    Outcome disparities associated with lower extremity bypass (LEB) for peripheral artery disease (PAD) have been identified but are poorly understood. Marital status may affect outcomes through factors related to health risk behaviors, adherence, and access to care but has not been characterized as a predictor of surgical outcomes and is often omitted from administrative data sets. We evaluated associations between marital status and vein graft patency following LEB using multivariable models adjusting for established risk factors. Consecutive patients undergoing autogenous LEB for PAD were identified and analyzed. Survival analysis and Cox proportional hazards models were used to evaluate patency stratified by marital status (married versus single, divorced, or widow[er]) adjusting for demographic, comorbidity, and anatomic factors in multivariable models. Seventy-three participants who underwent 79 autogenous vein LEB had complete data and were analyzed. Forty-three patients (58.9%) were married, and 30 (41.1%) were unmarried. Compared with unmarried patients, married patients were older at the time of their bypass procedure (67.3 ± 10.8 years vs. 62.2 ± 10.6 years; P = 0.05). Married patients also had a lower prevalence of female gender (11.6% vs. 33.3%; P = 0.02). Diabetes, hypertension, hyperlipidemia, and smoking were common among both married and unmarried patients. Minimum great saphenous vein conduit diameters were larger in married versus unmarried patients (2.82 ± 0.57 mm vs. 2.52 ± 0.65 mm; P = 0.04). Twenty-four-month primary patency was 66% for married versus 38% for unmarried patients. In a multivariable proportional hazards model adjusting for proximal and distal graft inflow/outflow, medications, gender, age, race, smoking, diabetes, and minimum vein graft diameter, married status was associated with superior primary patency (hazard ratio [HR] = 0.33; 95% confidence limits [0.11, 0.99]; P = 0.05); other predictive covariates

  20. Mechanical properties of radial bone defects treated with autogenous graft covered with hydroxyapatite in rabbit Propriedades mecânicas de defeito de osso radial tratado com enxerto autógeno coberto com nano-hydroxyapatite em coelho

    Directory of Open Access Journals (Sweden)

    Davood Sharifi

    2012-03-01

    Full Text Available PURPOSE: To determine biomechanical property of autogenous bone graft covered with hydroxyapatite in the defect of radial bone in rabbit. METHODS: Eighteen adult male New Zealand white rabbits were used which were divided into three groups (I, II, III of six rabbits each. A segmental bone defect of 10 mm in length was created in the middle of the right radial shaft under general effective anesthesia in all rabbits and were stabilized using mini-plate with four screws. The defects In group I were left as such without filler, whereas in group II the defect were filled up with harvested 10 mm rib bone and in group III the defect were packed with rib bone covered with nano-hydroxyapatite. All rabbits in three groups were divided into two subgroups (one month and three months duration with three rabbits in each one. RESULTS: The mechanical property and the mean load for fracturing normal radial bone was recorded 388.2±6 N whereas it was 72.4±12.8 N for group I in 1 month duration which was recorded 182.4±14.2 N for group II and 211.6±10.4 N for group III at the end of 1 month. These values were 97.6±10.2 N for group I and 324.6±8.2 N for group II and 372.6±17.4 N for group III at the end of three months after implantation. CONCLUSION: Implantation of autologous graft covered with hydroxyapatite indicated to have positive effect in integral formation of qualitative callus at the site of fracture and early re-organization of callus to regain mechanical strength too.OBJETIVO: Determinar as propriedades biomecânicas de enxerto ósseo autógeno coberto com hidroxiapatita em defeito do osso radial em coelhos. MÉTODOS: Foram utilizados 18 coelhos adultos, machos, brancos, Nova Zelândia, distribuídos em três grupos (I, II, III de seis coelhos cada. Um defeito segmentar de 10 mm de comprimento foi criado no meio do eixo radial direito sob anestesia geral efetiva em todos os coelhos e foram fixados usando mini-placa com quatro parafusos. Os

  1. Factors associated with mortality in patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Koerich, Cintia; Lanzoni, Gabriela Marcellino de Melo; Erdmann, Alacoque Lorenzini

    2016-08-08

    to investigate the factors associated with mortality in patients undergoing coronary artery bypass grafting in a cardiovascular referral hospital in Santa Catarina. quantitative, exploratory, descriptive and retrospective study. The medical records of 1447 patients, from 2005 to 2013, were analyzed for statistically related variables, these being: profile, hospitalization diagnosis, risk factors for coronary artery disease, complications recorded during the hospitalization, length of hospitalization and cause of death. the mortality rate was 5.3% during the study period. Death was more common in females and those of black skin color, with a mean age of 65 years. Acute myocardial infarction was the most common hospitalization diagnosis. The majority of the complications recorded during hospitalization were characterized by changes in the cardiovascular system, with longer hospitalization periods being directly related to death from septic shock. the data provide subsidies for nursing work with preventive measures and early detection of complications associated with coronary artery bypass grafting. This reinforces the importance of using the data as quality indicators, aiming to guarantee care guided by reliable information to guide managers in planning patient care and high complexity health services. conhecer os fatores associados à mortalidade de pacientes submetidos à cirurgia de revascularização do miocárdio em hospital referência cardiovascular em Santa Catarina. estudo quantitativo, exploratório, descritivo e retrospectivo. Foram analisados os prontuários de 1447 pacientes, entre 2005 e 2013, e as variáveis relacionadas estatisticamente, sendo estas: perfil, diagnóstico da internação, fatores de risco para doença arterial coronariana, intercorrências registradas na internação, tempo de internação e causa do óbito. a taxa de mortalidade foi de 5,3% no período do estudo. Os óbitos foram mais frequentes em negros, do sexo feminino e média de

  2. Improved patency and reduced intimal hyperplasia in PTFE grafts with luminal immobilized heparin compared with standard PTFE grafts at six months in a sheep model.

    Science.gov (United States)

    Pedersen, G; Laxdal, E; Ellensen, V; Jonung, T; Mattsson, E

    2010-06-01

    The aim of this study was to compare the performance of polytetrafluoroethylene (PTFE) grafts with luminal coating of immobilized heparin to that of standard PTFE grafts at six months. Twenty-eight common carotid arteries in fourteen sheep were bypassed with heparin-coated PTFE grafts (6 mm diameter, 6 cm length) on one side and standard PTFE grafts on the other. The grafts were explanted after six months. The thickness of intimal hyperplasia (IH) in open grafts was measured with histomorphometrical methods. Two of 14 heparinized PTFE grafts and nine of 14 grafts in the control PTFE-group were occluded at explantation (P=0.006). Six-month patency rates for heparinized PTFE grafts and for standard PTFE grafts were 86% and 36%, respectively. Mean graft anastomotic IH thickness in open grafts were 0.074 mm for heparinized PTFE grafts and 0.259 mm for PTFE-grafts (P=0.006). PTFE grafts with luminal coating containing immobilized heparin had significantly better patency and recruited less intimal hyperplasia than standard PTFE grafts at six months.

  3. Nonfunctioning Renal Allograft Embolization as an Alternative to Graft Nephrectomy: Report on Seven Years' Experience

    International Nuclear Information System (INIS)

    Atar, Eli; Belenky, Alexander; Neuman-Levin, Margalit; Yussim, A.; Bar-Nathan, Nathan; Bachar, Gil N.

    2003-01-01

    Purpose: Graft nephrectomy is the treatment of choice in patients with graft intolerance syndrome, but it is associated with high morbidity and mortality rates. Renal vascular embolization has been suggested as a possible alternative. The aim of this study was to evaluate the efficacy and safety of arterial embolization of these nonfunctioning transplanted kidneys. Methods: Twenty-six transplanted kidneys in 25 patients with irreversible renal graft rejection and graft intolerance who underwent arterial embolization at our center from August 1994 to April 2001 we reanalyzed for procedural success and long-term outcome. Embolization was performed with absolute alcohol or with polyvinyl alcohol (Ivalon) and coils. Results: Twenty-four of the 26 (92%) procedures were technically successful, but in one patient only partial occlusion of one of two renal arteries was achieved, and in another the renal artery was already completely occluded. There were two major complications: emphysematous pyelonephritis necessitating nephrectomy and groin abscess that was drained. Follow-up ranged from 8 to 84 months. Clinical success was achieved in 24 of the 26 procedures(92%), and only in one patient did embolization fail to relieve the symptoms, and nephrectomy was performed 3 months later. Conclusion: Renal vascular embolization is a simple, safe and effective technique for the treatment of nonfunctioning renal allografts associated with graft intolerance syndrome. We suggest that it be considered the treatment of choice

  4. Heparin-bonded, expanded polytetrafluoroethylene-lined stent graft in the treatment of femoropopliteal artery disease: 1-year results of the VIPER (Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease) trial.

    Science.gov (United States)

    Saxon, Richard R; Chervu, Arun; Jones, Paul A; Bajwa, Tanvir K; Gable, Dennis R; Soukas, Peter A; Begg, Richard J; Adams, John G; Ansel, Gary M; Schneider, Darren B; Eichler, Charles M; Rush, Michael J

    2013-02-01

    To evaluate the performance of a heparin-bonded, expanded polytetrafluoroethylene (ePTFE)-lined nitinol endoprosthesis in the treatment of long-segment occlusive disease of the femoropopliteal artery (FPA) and to identify factors associated with loss of patency. In a single-arm, prospective, 11-center study (VIPER [Gore Viabahn Endoprosthesis with Heparin Bioactive Surface in the Treatment of Superficial Femoral Artery Obstructive Disease] trial), 119 limbs (113 patients; 69 men; mean age, 67 y), including 88 with Rutherford category 3-5 disease and 72 with Inter-Society Consensus for the Management of Peripheral Arterial Disease (TASC II) C or D lesions of the FPA, underwent stent graft implantation. The mean lesion length was 19 cm; 56% of lesions were occlusions. Follow-up evaluations included color duplex ultrasonography in all patients, with patency defined as a peak systolic velocity ratio20% was 70% (P = .047). Primary patency was not significantly affected by device diameter (5 vs 6 vs 7 mm) or lesion length (≤20 cm vs>20 cm). The 30-day major adverse event rate was 0.8%. The heparin-bonded, ePTFE/nitinol stent graft provided clinical improvement and a primary patency rate of 73% at 1 year in the treatment of long-segment FPA disease. Careful sizing of the device relative to vessel landing zones is essential for achieving optimal outcomes. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  5. Radial force measurement of endovascular stents: Influence of stent design and diameter.

    Science.gov (United States)

    Matsumoto, Takuya; Matsubara, Yutaka; Aoyagi, Yukihiko; Matsuda, Daisuke; Okadome, Jun; Morisaki, Koichi; Inoue, Kentarou; Tanaka, Shinichi; Ohkusa, Tomoko; Maehara, Yoshihiko

    2016-04-01

    Angioplasty and endovascular stent placement is used in case to rescue the coverage of main branches to supply blood to brain from aortic arch in thoracic endovascular aortic repair. This study assessed mechanical properties, especially differences in radial force, of different endovascular and thoracic stents. We analyzed the radial force of three stent models (Epic, E-Luminexx and SMART) stents using radial force-tester method in single or overlapping conditions. We also analyzed radial force in three thoracic stents using Mylar film testing method: conformable Gore-TAG, Relay, and Valiant Thoracic Stent Graft. Overlapping SMART stents had greater radial force than overlapping Epic or Luminexx stents (P stents was greater than that of all three endovascular stents (P stents, site of deployment, and layer characteristics. In clinical settings, an understanding of the mechanical characteristics, including radial force, is important in choosing a stent for each patient. © The Author(s) 2015.

  6. A Case of Successful Simultaneous Pancreas-Kidney Transplantation Using the Injured Pancreas Graft.

    Science.gov (United States)

    Miyagi, S; Shimizu, K; Miyazawa, K; Nakanishi, W; Hara, Y; Tokodai, K; Nakanishi, C; Satomi, S; Goto, M; Unno, M; Kamei, T

    2017-12-01

    Graft injuries sometimes occur and may cause complications such as the leakage of pancreatic secretions, which is often lethal. We report our experience of a case of successful simultaneous pancreas-kidney transplantation using injured pancreas graft. The recipient was a 57-year-old woman with type 1 diabetes mellitus, and the donor was a 30-year-old man with a brain injury. In the donation, the pancreas parenchyma, splenic artery, and gastroduodenal artery were injured iatrogenically. We therefore reconstructed these arteries using vessel grafts and then performed simultaneous pancreas-kidney transplantation. Five days after transplantation, we noted a high titer of amylase in the ascites; therefore, we performed an urgent laparotomy. The origin of the amylase was the injured pancreatic parenchyma, and continued washing and drainage were carried out. We reconstructed the duodenojejunostomy using the Roux-en-Y technique to separate the passage of food from the pancreas graft to prevent injury to other organs due to exposure to pancreatic secretions. Thereafter, we inserted a decompression tube into the anastomosis thorough the blind end of the jejunum. Finally, we inserted 3 drainage tubes for lavage. Following this procedure, the patient recovered gradually and no longer required hemodialysis and insulin therapy. She was discharged from our hospital 56 days after transplantation. The restoration of the injured graft was possible by management of pancreatic secretions and use of the donor's vessel grafts. Shortage of donors is a problem throughout the world; thus, it is important to use injured grafts for transplantation if possible. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Donor-site morbidity of the radial forearm free flap versus the ulnar forearm free flap.

    Science.gov (United States)

    Hekner, Dominique D; Abbink, Jan H; van Es, Robert J; Rosenberg, Antoine; Koole, Ronald; Van Cann, Ellen M

    2013-08-01

    Donor-site morbidity following harvest of the radial forearm free flap was compared with that following harvest of the ulnar forearm free flap. Twenty-eight radial forearm and 27 ulnar forearm flaps were harvested in 55 patients with head and neck defects. Pressure perception was measured with Semmes-Weinstein monofilaments. Cold perception was tested with chloroethyl. Donor-site healing was evaluated. Patients were interviewed about grip and pinch strength and donor-site appearance. In the radial forearm free flap group, pressure perception and cold perception were reduced in the donor hand, whereas in the ulnar group, no differences were observed between the donor and unoperated hands. In the radial forearm group, 15 percent of patients experienced reduced strength in the donor hand, whereas in the ulnar forearm group, none of the patients reported reduced strength in the donor hand. In the radial forearm group, 14 percent had partial or complete loss of the skin graft, whereas in the ulnar forearm group, 4 percent had partial loss of the skin graft. In the radial forearm group, 18 percent of patients were dissatisfied with the appearance of the donor site, and no complaints were reported in the ulnar forearm group. The authors' study shows less donor site-morbidity following harvest of the ulnar forearm free flap than following harvest of the radial forearm free flap. These results emphasize that the ulnar forearm free flap should be considered as an alternative for the radial forearm free flap for reconstruction of soft-tissue defects. Therapeutic, III.

  8. Successful intra-arterial alteplase infusion is a predictor of 12-month limb survival in patients with lower limb arterial occlusion

    International Nuclear Information System (INIS)

    Disini, L.; Wilson, P.; Cockburn, J.F.

    2008-01-01

    Aim: To determine the factors predicting amputation of the affected lower limb 12 months after thrombolysis for acute arterial occlusion. Materials and methods: The clinical endpoints of 39 patients (24 men, 15 women; average age 69 years) 1 year after catheter-directed thrombolysis with alteplase (mean dose 30 mg, mean duration 24 h) for lower limb arterial occlusion (30 native arteries, nine grafts) from January 2001 to June 2005 were assessed. The amputation rate at 12 months was analysed in relation to the thrombolytic outcome, type of vessel occluded, presence or absence of complications, and subsequent requirement for additional surgery on an elective basis using Fischer's exact test. Results: Successful thrombolysis, defined as complete clot dissolution based on angiographic imaging, was achieved in 64.1% of cases (19 native artery, six bypass graft) with a total complication rate of 23% (n = 9). The incidence of major haemorrhage was 7.5% (n = 3, hypotension and haematemesis, groin haematoma and hypotension, haematemesis). No patient had an intracranial bleed. One year after thrombolysis, 28.2% (n = 11) had further surgery (bypass graft, fasciotomy, embolectomy) and the amputation rate was 20.5% (n = 8). Statistical analysis showed that the amputation rate was significantly higher for patients with failed compared with successful thrombolysis (p = 0.02). The amputation rates did not reach statistical significance in relation to native artery or graft occlusion, presence or absence of complications, and whether or not additional surgery was required. Conclusion: Successful thrombolysis was a predictor for limb survival up to 12 months post-thrombolysis regardless of the type of vessel occlusion, presence of complications or additional surgical requirement

  9. Effect of nutritional status on mortality in patients undergoing coronary artery bypass grafting.

    Science.gov (United States)

    Keskin, Muhammed; İpek, Göktük; Aldağ, Mustafa; Altay, Servet; Hayıroğlu, Mert İlker; Börklü, Edibe Betül; İnan, Duygu; Kozan, Ömer

    2018-04-01

    The prognostic effects of poor nutritional status and cardiac cachexia on coronary artery disease (CAD) are not clearly understood. A well-accepted nutritional status parameter, the prognostic nutritional index (PNI), which was first demonstrated to be valuable in patients with cancer and those undergoing gastrointestinal surgery, was introduced to patients requiring coronary artery bypass grafting (CABG). The aim of the present study was to evaluate the prognostic value of PNI in patients with CAD undergoing CABG. We evaluated the in-hospital and long-term (3-y) prognostic effect of PNI on 644 patients with CAD undergoing CABG. Baseline characteristics and outcomes were compared among the patients by PNI and categorized accordingly: Q1, Q2, Q3, and Q4. Patients with lower PNI had significantly higher in-hospital and long-term mortality. Patients with lower PNI levels (Q1) had higher in-hospital mortality and had 12 times higher mortality rates than those with higher PNI levels (Q4). The higher PNI group had the lower rates and was used as the reference. Long-term mortality was higher in patients with lower PNI (Q1)-4.9 times higher than in the higher PNI group (Q4). In-hospital and long-term mortality rates were similar in the non-lower PNI groups (Q2-4). The present study demonstrated that PNI, calculated based on serum albumin level and lymphocyte count, is an independent prognostic factor for mortality in patients undergoing CABG. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Invasive angiography and revascularization in patients with stable angina following prior coronary artery bypass grafting

    DEFF Research Database (Denmark)

    Joshi, Francis R; Biasco, Luigi; Pedersen, Frants

    2017-01-01

    . Follow-up data were available for all patients, by means of records linked to each Danish social security number. RESULTS: In patients with prior CABG and stable angina (n = 2,309), diagnostic angiography led to revascularization in 574 (24.9%) cases. Chronic kidney disease (HR 1.93 [1.08-3.44], P = 0......BACKGROUND: There are limited data to guide the optimum approach to patients presenting with angina after coronary artery bypass grafting (CABG). Although often referred for invasive angiography, the effectiveness of this is unknown; angina may also result from diffuse distal or micro......-vascular coronary disease and it is not known how often targets for intervention are identified. METHODS: Retrospective review of 50,460 patients undergoing angiography in East Denmark between January 2010 and December 2014. Clinical and procedural data were prospectively stored in a regional electronic database...

  11. [Anatomy character of renal artery and treatment of living-donor renal transplantation].

    Science.gov (United States)

    Zhang, Lei; Fei, Ji-guang; Chen, Li-zhong; Wang, Chang-xi; Deng, Su-xiong; Qiu, Jiang; Li, Jun; Chen, Guo-dong; Huang, Gang

    2009-12-15

    To study the anatomy characters of renal artery and the treatment of multiple arteries in living donor renal grafts. Records of 142 living donors were analyzed in our center. We analyzed the anatomic structure of renal arteries by DSA and CTA pre-transplantation. Thirty-one kidneys with multiple arteries were transplanted after reconstruction. Then clinical effects were compared between multiple-renal-arteries group (n=31) and single-renal-artery group (n=111). The incidence of multiple renal artery was 30.99%, and there was no difference between both sides (left kidney 22.54%, right kidney 22.13%). If the multiple artery occurred in left or right kidney, the incidence of the multiple artery occurred in the other side was 56.25% and 60.00%, respectively. The diameter of left main renal artery was more magnanimous (P=0.001) and the first branch was more closed to abdominal aorta (P=0.004). Operation time and warm/cool ischemia time were longer in the multiple-renal-arteries group. However, estimated blood loss, delayed graft function, acute rejection and flow rate of arcuate artery were similar in both groups, the same as serum creatinine and serum creatinine clearance rate on day 7, 1 month and 3 month post-operation. It was shown by repeated measures ANOVA that graft with multiple arteries didn't affect the tendency of renal function at early time post-operation. Comprehending the character of renal artery and accurate treatment of multiple artery anastomosis are critical for the effect of the living kidney transplantation.

  12. Retransplantation in Late Hepatic Artery Thrombosis: Graft Access and Transplant Outcome

    Directory of Open Access Journals (Sweden)

    Bettina M. Buchholz, MD, FEBS

    2017-08-01

    Conclusions. Inequity in graft access and peritransplant sepsis are fundamental obstacles for successful re-LT in L-HAT. Offering a graft for those in need at the best window of opportunity could facilitate earlier engrafting with improved outcomes.

  13. Routine closure of the donor site with a second dorsal metacarpal artery flap to avoid the use of a skin graft after harvest of a first dorsal metacarpal artery flap.

    Science.gov (United States)

    Chi, Zhenglin; Lin, Damu; Chen, Yiheng; Xue, Jixin; Li, Shi; Chu, Tinggang; Li, Zhijie

    2018-06-01

    Closure of the donor site on the index finger after raising a first dorsal metacarpal artery (DMA) flap harvest is challenging. The conventional choice is to use a full-thickness skin graft. However, this procedure is associated with several complications and a second donor site to harvest the skin graft is inevitable. The aim of this study was to design a modified incision to allow harvest of a first DMA flap without skin graft. From 2015 to 2016, 18 patients with a soft tissue defect of the thumb had reconstruction of the defect using a first DMA flap. A modified incision was used and a relaying perforator flap pedicled on the second DMA was raised through the same incision to cover the donor site. Patient satisfaction, appearance of the injured hand, and the active range of motion (ROM) were assessed. The sensitivity was evaluated by the 2-point discrimination (2-PD) test. All flaps survived completely without complications. Good coverage was obtained with only one linear scar in the dorsum of the hand and no skin grafts. All patients recovered full range of movement in their fingers and regained sensitivity of the flaps. All patients were satisfied with their hand function according to the Michigan Hand Outcomes Questionnaire (MHQ). The mean cosmetic score for the appearance of the injured hand was 8.2 out of 10. Using our modified incision, it was possible to harvest a second DMA flap at the same time as a first DMA flap allowing simultaneous coverage of the donor defect on the index finger. This prevented the need for a skin graft with all of the associated disadvantages. Copyright © 2018. Published by Elsevier Ltd.

  14. Effect of Xenon Anesthesia Compared to Sevoflurane and Total Intravenous Anesthesia for Coronary Artery Bypass Graft Surgery on Postoperative Cardiac Troponin Release: An International, Multicenter, Phase 3, Single-blinded, Randomized Noninferiority Trial.

    Science.gov (United States)

    Hofland, Jan; Ouattara, Alexandre; Fellahi, Jean-Luc; Gruenewald, Matthias; Hazebroucq, Jean; Ecoffey, Claude; Joseph, Pierre; Heringlake, Matthias; Steib, Annick; Coburn, Mark; Amour, Julien; Rozec, Bertrand; Liefde, Inge de; Meybohm, Patrick; Preckel, Benedikt; Hanouz, Jean-Luc; Tritapepe, Luigi; Tonner, Peter; Benhaoua, Hamina; Roesner, Jan Patrick; Bein, Berthold; Hanouz, Luc; Tenbrinck, Rob; Bogers, Ad J J C; Mik, Bert G; Coiffic, Alain; Renner, Jochen; Steinfath, Markus; Francksen, Helga; Broch, Ole; Haneya, Assad; Schaller, Manuella; Guinet, Patrick; Daviet, Lauren; Brianchon, Corinne; Rosier, Sebastien; Lehot, Jean-Jacques; Paarmann, Hauke; Schön, Julika; Hanke, Thorsten; Ettel, Joachym; Olsson, Silke; Klotz, Stefan; Samet, Amir; Laurinenas, Giedrius; Thibaud, Adrien; Cristinar, Mircea; Collanges, Olivier; Levy, François; Rossaint, Rolf; Stevanovic, Ana; Schaelte, Gereon; Stoppe, Christian; Hamou, Nora Ait; Hariri, Sarah; Quessard, Astrid; Carillion, Aude; Morin, Hélène; Silleran, Jacqueline; Robert, David; Crouzet, Anne-Sophie; Zacharowski, Kai; Reyher, Christian; Iken, Sonja; Weber, Nina C; Hollmann, Marcus; Eberl, Susanne; Carriero, Giovanni; Collacchi, Daria; Di Persio, Alessandra; Fourcade, Olivier; Bergt, Stefan; Alms, Angela

    2017-12-01

    Ischemic myocardial damage accompanying coronary artery bypass graft surgery remains a clinical challenge. We investigated whether xenon anesthesia could limit myocardial damage in coronary artery bypass graft surgery patients, as has been reported for animal ischemia models. In 17 university hospitals in France, Germany, Italy, and The Netherlands, low-risk elective, on-pump coronary artery bypass graft surgery patients were randomized to receive xenon, sevoflurane, or propofol-based total intravenous anesthesia for anesthesia maintenance. The primary outcome was the cardiac troponin I concentration in the blood 24 h postsurgery. The noninferiority margin for the mean difference in cardiac troponin I release between the xenon and sevoflurane groups was less than 0.15 ng/ml. Secondary outcomes were the safety and feasibility of xenon anesthesia. The first patient included at each center received xenon anesthesia for practical reasons. For all other patients, anesthesia maintenance was randomized (intention-to-treat: n = 492; per-protocol/without major protocol deviation: n = 446). Median 24-h postoperative cardiac troponin I concentrations (ng/ml [interquartile range]) were 1.14 [0.76 to 2.10] with xenon, 1.30 [0.78 to 2.67] with sevoflurane, and 1.48 [0.94 to 2.78] with total intravenous anesthesia [per-protocol]). The mean difference in cardiac troponin I release between xenon and sevoflurane was -0.09 ng/ml (95% CI, -0.30 to 0.11; per-protocol: P = 0.02). Postoperative cardiac troponin I release was significantly less with xenon than with total intravenous anesthesia (intention-to-treat: P = 0.05; per-protocol: P = 0.02). Perioperative variables and postoperative outcomes were comparable across all groups, with no safety concerns. In postoperative cardiac troponin I release, xenon was noninferior to sevoflurane in low-risk, on-pump coronary artery bypass graft surgery patients. Only with xenon was cardiac troponin I release less than with total intravenous

  15. Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs--preliminary observations.

    Science.gov (United States)

    Nemcova, S; Noel, A A; Jost, C J; Gloviczki, P; Miller, V M; Brockbank, K G

    2001-01-01

    Autogenous veins are the materials of choice for arterial reconstruction. In the absence of autogenous material, prosthetic materials are used. However, vascular prostheses of less than 0.4 cm in diameter have low long-term patency. This study was designed to determine if cells would infiltrate an engineered xenogeneic biomaterial used as a small diameter arterial graft in dogs and, if so, to determine the phenotype of the infiltrating cells. Nine acellular xenogeneic grafts (0.4 cm in diameter, 5 cm long), composed of porcine collagen derived from the submucosa of the small intestine and type I bovine collagen, were implanted as end to-end interposition grafts in femoral arteries of five male mongrel dogs (total of nine grafts). All dogs received daily aspirin (325 mg). Patency of implanted grafts was monitored weekly by Duplex ultrasonography. After 9 weeks, or earlier in case of blood flow reduction by at least 75%, grafts were explanted and prepared for light or electron microscopy to evaluate cellularization. Eight of nine grafts remained patent up to 9 weeks. At explant, diameters were 0.31 +/- 0.02 cm at the midgraft, and 0.14 +/- 0.01 and 0.19 +/- 0.01 cm at the proximal and distal anastomoses. At explant, cells of mesenchymal origin (endothelial cells, smooth muscle cells, myofibroblasts) were embedded in the extracellular matrix of the graft scaffold. Minimal evidence of cellular inflammatory reaction and no aneurysmal dilatation or thrombus formation was detected. Variable degrees of hyperplasia were present at proximal and distal anastomoses. This preliminary study demonstrates that a collagen-based xenogeneic biomaterial provides a scaffold for cellularization when used for arterial reconstruction in dogs.

  16. Myocardial perfusion as an indicator of graft patency after coronary artery bypass surgery

    International Nuclear Information System (INIS)

    Kolibash, A.J.; Call, T.D.; Bush, C.A.; Tetalman, M.R.; Lewis, R.P.

    1980-01-01

    Stress and resting myocardial perfusion were assessed in 38 patients who received 96 grafts. Stress perfusion was evaluated with thallium-201 and resting myocardial blood flow distribution with radiolabeled particles. When both stress and rest perfusion were normal, graft patency was 82% (51 of 62 grafts). Graft patency was also high (81%, 13 of 16) in areas where stress perfusion abnormalities resolved or become less apparent at rest. However, when stress perfusion defects remained unchanged at rest, the graf was likely to be occuluded (73%, 11 of 15). Maintenance of normal rest perfusion or improvement of rest perfusion postoperatively was also associated with a high graft patency rate (80%, 35 of 44), whereas the development of new rest perfusion defects postoperatively implied graft occlusion

  17. Process review of a departmental change from conventional coronary artery bypass grafting to totally arterial coronary artery bypass and its effects on the incidence and severity of postoperative stroke.

    Science.gov (United States)

    Albert, Alexander; Sergeant, Paul; Florath, Ines; Ismael, Mohammed; Rosendahl, Ulrich; Ennker, Jürgen

    2011-04-01

    We evaluated the process of changing from conventional coronary artery bypass grafting (CABG) to totally arterial off-pump coronary artery bypass (TOPCAB) at a single heart center in Germany. We (1) used multivariate statistical methods to assess real-time monitoring of OPCAB effects, (2) conducted a case review to assess preventable deaths and identify areas of improvement, (3) conducted a team survey, and (4) evaluated benchmarking results. All surgeons and assistants (n = 18) at this center were involved and were guided by the department head and one of the consultants, who was trained in this procedure in 2004 at the Leuven OPCAB school. The frequency of OPCAB operations increased abruptly in 2005 from 5% to 43% and then increased gradually to 67% (n = 546) by 2008 (total, 1781 OPCAB cases and 1563 on-pump cases). The in-hospital and 30-day mortality rates for OPCAB surgeries (n = 10 [0.6%] and 21 [1.2%], respectively) were lower than for on-pump surgeries (n = 27 [1.7%] and 26 [1.7%], respectively). Stroke rates were also lower for OPCAB surgeries (7 cases [0.4%] versus 15 cases [1%]). The lower risk of stroke in the OPCAB group was significant (P popularity, and a top national rank). The change from conventional CABG to TOPCAB was effective in decreasing the incidence and severity of stroke, in developing a team routine and a positive team attitude, and in producing excellent benchmarking results. The presence of a training and communication deficiency at the beginning of the study suggested an area for further improvement. After 6 years TOPCAB had largely replaced conventional CABG.

  18. Can opium abuse be a risk factor for carotid stenosis in patients who are candidates for coronary artery bypass grafting?

    Science.gov (United States)

    Shirani, Shapour; Shakiba, Madjid; Soleymanzadeh, Maryam; Esfandbod, Maryam

    2010-01-01

    Over the centuries, opium has been the most frequent substance abused in the Middle East. There are many controversial aspects about the effects of opioids on the atherosclerosis process, which is still unclear. All patients who were candidates for coronary artery bypass graft in Tehran Heart Center were registered and evaluated for risk factors such as diabetes mellitus, hypertension, smoking status and duration, opium abuse, involved coronary arteries and left main branch lesion > 50%, carotid stenosis > or = 70%. A total of 1,339 patients were enrolled in the study, of whom 400 (29.9%) were female and the other 939 (70.1%) male. Female patients were omitted from analysis due to the low numbers of female opium addicts. Our study revealed that in the addicted population, the risk of diabetes and hypertension was lower than in the non-addicted group (p 50% and extent of carotid stenosis was not significantly different between the two groups. Our investigations demonstrate that opium is not cardioprotective, as has been claimed by some previous studies, and does not even decelerate atherosclerosis of carotid arteries in opium-addicted patients, but more evidence is still needed to completely prove the case.

  19. Development of an abdominal aortic aneurysm model for stent-graft insertion

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hyung; Lee, Jong Heon; Shin, Dong Ik; Sung, Kyu Bo; Ko, Gi Young; Lim, Jin Oh [College of Medicine, Univ. of Ulsan, Seoul (Korea, Republic of); Kim, Si Hoon [S and G Biotech Research Institute, Seoul (Korea, Republic of)

    2002-03-01

    To determine the efficacy of an abdominal aortic aneurysm model for stent-graft placement. The model consists of two parts, the heart and the vascular system. A peristaltic pump and a solenoid valve were used to simulate a pulsatile flow from the heart. A ball-shaped piece of clay was placed inside a square box and liquid silicone was poured. After the silicone was formed, the clay was removed and a silicone tube was used to connect the heart model and the aneurysm model. The silicone tube was also used to simulate the iliac arteries and one end of the artery was clampled and the other one was extended to water bath. Water at 37 .deg. C was circulated through the model, and the pressure at the thoracic aorta, aneurysm and iliac artery was measured with the outlet valve opening at 25, 50, and 100% before and after stent-graft placement. The liquid pressure measurements were 253/252, 271/162 and 264/166 mmHg at the thoracic aorta, aneurysm and iliac artery, respectively, when the outlet was 100% open. They were 173/121, 145/99, 145/106 mmHg when the outlet was 50% open, and 35/28, 61/44, 24/22 mmHg when it was 25% open. After placement of the stent-graft, the pressure measurements were 170/128, and 167/128 mmHg, respectively. Since it was easy to produce, the model was useful for in-vitro stent-graft testing, and a wide range of pressure could be applied.

  20. Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan

    Directory of Open Access Journals (Sweden)

    Nurhusna N

    2017-08-01

    Full Text Available Page Header User Username Password Remember me Editorial Team Editor Policies Mechanism & Ethics Author Guideline Reference Tools: About The Authors Nurhusna N Indonesia F Sri Susilaningsih Purwo Suwigjo Article Tools Print this article Indexing metadata How to cite item Finding References Review policy Email this article (Login required Email the author (Login required Information For Readers For Authors For Librarians Journal Content Search Search Scope Browse By Issue By Author By Title Home About Login Register Search Current Archives Announcements Register Index Contact Us Home > Vol 2, No 1 (2014 > N Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan Nurhusna N, F Sri Susilaningsih, Purwo Suwigjo Abstract Radial artery occlusion merupakan salah satu komplikasi vaskular postkateterisasi jantung trans radial. Kompresi lokal menggunakan alat kompresi setelah tindakan kateterisasi jantung trans radial dapat menurunkan angka kejadian komplikasi vaskular Radial Artery Occlusion(RAO. Penelitian ini bertujuan untuk mengetahui perbandingan antara metode Barbeau test dan metode pengamatan klinik dalam menilai keutuhan arteri radialis selama proses kompresi pada pasien postprosedur kateterisasi jantung trans radial. Penelitian ini merupakan penelitian kuantitatif dengan desain studi komparatif. Subjek penelitian adalah 20 pasien yang menjalani prosedur kateterisasi jantung dengan akses arteri radialis. Pengukuran dilakukan secara bertahap menit ke-15 dan setelah tiga jam menggunakan alat kompresi stepty-p. Uji komparasi menggunakan uji McNemar. Data univariat dianalisis menggunakan distribusi frekuensi. Hasil uji statistik menunjukkan ada perbedaan penilaian keutuhan arteri radialis antara metode Barbeau testdengan metode pengamatan klinik pada menit ke-15 (p=0.035 dan ke-30 (p=0.035. Namun secara keseluruhan hasil uji statistik menunjukkan tidak ada perbedaan yang bermakna dalam menilai kepatenan arteri pada

  1. Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke

    International Nuclear Information System (INIS)

    Bok, Tae Hoon; Kong, Qi; Nam, Kweon Ho; Choi, Jay Chol; Paeng, Dong Guk

    2012-01-01

    In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group (0.13±0.21 and 0.16±0.03). PIBE of CCA for the young group, however, was larger than that for the old group (0.70±0.21 and 0.32±0.01), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients (336±61 and 340±126 mg/dl) were more than that of the control group (264±38 and 43 mg/dl), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

  2. Detection of imminent vein graft occlusion: what is the optimal surveillance program?

    Science.gov (United States)

    Tinder, Chelsey N; Bandyk, Dennis F

    2009-12-01

    The prediction of infrainguinal vein bypass failure remains an inexact judgment. Patient demographics, technical factors, and vascular laboratory graft surveillance testing are helpful in identifying a high-risk graft cohort. The optimal surveillance program to detect the bypass at risk for imminent occlusion continues to be developed, but required elements are known and include clinical assessment for new or changes in limb ischemia symptoms, measurement of ankle and/or toe systolic pressure, and duplex ultrasound imaging of the bypass graft. Duplex ultrasound assessment of bypass hemodynamics may be the most accurate method to detect imminent vein graft occlusion. The finding of low graft flow during intraoperative assessment or at a scheduled surveillance study predicts failure; and if associated with an occlusive lesion, a graft revision can prolong patency. The most common abnormality producing graft failure is conduit stenosis caused by myointimal hyperplasia; and the majority can be repaired by an endovascular intervention. Frequency of testing to detect the failing bypass should be individualized to the patient, the type of arterial bypass, and prior duplex ultrasound scan findings. The focus of surveillance is on identification of the low-flow arterial bypass and timely repair of detected critical stenosis defined by duplex velocity spectra criteria of a peak systolic velocity 300 cm/s and peak systolic velocity ratio across the stenosis >3.5-correlating with >70% diameter-reducing stenosis. When conducted appropriately, a graft surveillance program should result in an unexpected graft failure rate of <3% per year.

  3. Successful technical and clinical outcome using a second generation balloon expandable coronary stent for transplant renal artery stenosis: Our experience.

    Science.gov (United States)

    Salsamendi, Jason; Pereira, Keith; Baker, Reginald; Bhatia, Shivank S; Narayanan, Govindarajan

    2015-10-01

    Transplant renal artery stenosis (TRAS) is a vascular complication frequently seen because of increase in the number of renal transplantations. Early diagnosis and management is essential to optimize a proper graft function. Currently, the endovascular treatment of TRAS using angioplasty and/or stenting is considered the treatment of choice with the advantage that it does not preclude subsequent surgical correction. Treatment of TRAS with the use of stents, particularly in tortuous transplant renal anatomy presents a unique challenge to an interventional radiologist. In this study, we present three cases from our practice highlighting the use of a balloon-expandable Multi-Link RX Ultra coronary stent system (Abbott Laboratories, Abbott Park, Illinois, USA) for treating high grade focal stenosis along very tortuous renal arterial segments. Cobalt-Chromium alloy stent scaffold provides excellent radial force, whereas the flexible stent design conforms to the vessel course allowing for optimal stent alignment.

  4. Interventional procedures of the isolated iliac arterial aneurysm

    Energy Technology Data Exchange (ETDEWEB)

    Ohm, Joon Young [The Catholic Univ. of Korea College of Medicine, Bucheon (Korea, Republic of); Shin, Byung Seok; Ahn, Moon Sang [Chungnam National Univ. Hospital, Daejeon (Korea, Republic of); Park, Mi Hyun [Dankook Univ. Hospital, Cheonan (Korea, Republic of); Kim, Ho Jun [Konyang Univ. Hospital, Daejeon (Korea, Republic of)

    2012-05-15

    To report the results of treatment isolated iliac arterial aneurysms by interventional procedures. Over a period of 5 years, 7 isolated iliac artery aneurysms (4 in the common iliac artery, 3 in the internal iliac artery) in 7 patients (3 women, 4 men; mean age, 65.7 years) were treated using interventional procedures. The mean aneurysm size was 35 mm (range, 30-45 mm). The common iliac aneurysms were treated using a unilateral stent graft (2 balloon expandable, 2 self expandable) with coil embolization of the internal iliac artery (n = 3), except for 1 aneurysm that ruptured. Coil embolization alone was performed for aneurysms involving only the internal iliac artery (n = 3). All patients were treated successfully, except for 1 with an initial remnant of type 2 endoleak. There were no perioperative complications. No leakage or complication occurred at the mean follow up of 14 months (range 2-29 months). One patient with a ruptured aneurysm died of multi organ failure during the follow up period. Three aneurysms had decreased in size on follow up CT. Interventional procedures with stent grafting and coil embolization are safe and effective treatments for isolated iliac artery aneurysms.

  5. The Impact of Anastomotic Angle for Re-Occlusion of Brachioaxillary Graft Arteriovenous Fistula after Percutaneous Thromboaspiration

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keon Young; Jin, Gong Yong; Hwang, Seung Bae; Choi, Eun Jung; Song, Ji Soo; Han, Young Min; Kwon, Keun Sang [Chonbuk National University Hospital and Medical School, Jeonju (Korea, Republic of)

    2013-03-15

    The purpose of this study is to evaluate the factors that affect graft patency in brachioaxillary graft arteriovenous fistula patients. A retrospective study was conducted on 33 patients (20 men, 13 women; mean age, 67.5 years; mean interval to first stenosis, 17 months), who had performed percutaneous angioplasty for first episode of stenosis after brachioaxillary graft surgery. We evaluated the relevant factors affecting the graft patency after first episode of stenosis, such as age, sex, underlying disease (hypertension, diabetes mellitus, hyperlipidemia, cardiovascular disease, cerebrovascular attack), anastomotic angle between graft and axillary vein, and anastomotic angle between the graft and brachial artery. Kaplan-Meier method and log rank test and receiver operating characteristics curve analysis were used in statistical analysis. Graft patency rates after 1 month, 6 months, and 12 months were 75.8%, 39.4%, and 9.1%. There was a correlation between graft-axillary vein anastomotic angle and patency rates (r = 0.372, p = 0.033); larger the venous anastomotic angle, the longer patency rate. However, it does not come up with significant results in patency rates on age, sex, underlying disease, and graft-brachial artery angle. In patients with brachioaxillary graft arteriovenous fistula, as venous anastomotic angle more obtuse, the graft patency may be longer.

  6. Pre-operative high sensitive C-reactive protein predicts cardiovascular events after coronary artery bypass grafting surgery: A prospective observational study

    Directory of Open Access Journals (Sweden)

    Balciunas Mindaugas

    2009-01-01

    Full Text Available C-reactive protein is a powerful independent predictor of cardiovascular events in patients with coronary artery disease. The relation between C-reactive protein (CRP concentration and in-hospital outcome, after coronary artery bypass grafting (CABG, has not yet been established. The study aims to evaluate the predictive value of pre-operative CRP for in-hospital cardiovascular events after CABG surgery. High-sensitivity CRP (hs-CRP levels were measured pre-operatively on the day of surgery in 66 patients scheduled for elective on pump CABG surgery. Post-operative cardiovascular events such as death from cardiovascular causes, ischemic stroke, myocardial damage, myocardial infarction and low output heart failure were recorded. During the first 30 days after surgery, 54 patients were free from observed events and 14 developed the following cardiovascular events: 10 (15% had myocardial damage, four (6% had low output heart failure and two (3% suffered stroke. No patients died during the follow-up period. Serum concentration of hs-CRP ≥ 3.3 mg/l (cut-off point obtained by ROC analysis was related to higher risk of post-operative cardiovascular events (36% vs 6%, P = 0.01, myocardial damage (24% vs 6%, P = 0.04 and low output heart failure (12% vs 0%, P = 0.04. Multivariate logistic regression analysis showed that hs-CRP ≥ 3.3 mg/l ( P = 0.002, O.R.: 19.3 (95% confidence interval (CI 2.9-128.0, intra-operative transfusion of red blood cells ( P = 0.04, O.R.: 9.9 (95% C.I. 1.1-85.5 and absence of diuretics in daily antihypertensive treatment ( P = 0.02, O.R.: 15.1 (95% C.I. 1.4-160.6 were independent predictors of combined cardiovascular event. Patients having hs-CRP value greater or equal to 3.3 mg/l pre-operatively have an increased risk of post-operative cardiovascular events after on pump coronary artery bypass grafting surgery.

  7. Acute transplant renal artery thrombosis due to distal renal artery stenosis: A case report and review of the literature

    OpenAIRE

    Fallahzadeh, Mohammad Kazem; Yatavelli, Rajini Kanth; Kumar, Ajay; Singh, Neeraj

    2014-01-01

    Background: Acute renal artery thrombosis is a devastating complication of renal transplantation that can result in graft loss if not detected early. Surgical and technical errors are the major cause of renal artery thrombosis. In this article, for the first time, we are reporting a case of acute renal artery thrombosis that developed early post-transplantation due to distal renal artery stenosis. Case Presentation: A 71-year-old woman presented with nausea, vomiting and decreased urine outpu...

  8. Bretschneider and del Nido solutions: Are they safe for coronary artery bypass grafting? If so, how should we use them?

    Science.gov (United States)

    Siddiqi, Shirin; Blackstone, Eugene H; Bakaeen, Faisal G

    2018-05-01

    A variety of cardioplegic solutions are being used widely today to arrest the heart during coronary artery bypass grafting (CABG) and other cardiac operations. To minimize interruptions during the surgery for intermittent dosing of the cardioplegia and to facilitate less invasive cardiac procedures, single-shot solutions, including Bretschneider and del Nido solutions, have been introduced. This review examines the evidence regarding the safety and efficacy of Bretschneider and del Nido cardioplegia during CABG. The findings support their use in routine low-risk CABG, but finds insufficient evidence to support their safety in high-risk surgeries. © 2018 Wiley Periodicals, Inc.

  9. Crossing Anatomic Barriers-Transplantation of a Kidney with 5 Arteries, Duplication of the Pyelocalyceal System, and Double Ureter.

    Science.gov (United States)

    Bachul, Piotr J; Osuch, Czesław; Chang, Ea-Sle; Bętkowska-Prokop, Alina; Pasternak, Artur; Szura, Mirosław; Matyja, Andrzej; Walocha, Jerzy A

    2017-10-01

    During the time of organ harvest, it is crucial for the kidney procurement team to consider significant vascular anatomical variations. Multiple renal arteries are not uncommon, and unintentional injury can result in an irreversibly damaged kidney graft that needs to be discarded. We present a kidney graft with 5 renal arteries and a single vein that was successfully procured and implanted with good graft function at discharge and at 4-yr follow-up. According to the literature, additional renal arteries can be found in about 33% of kidneys. This is the first study on a kidney with 5 arteries in the published literature, especially in the context of transplantation.

  10. Ex vivo repair of renal artery aneurysm associated with surgical treatment of abdominal aortic aneurysm

    Directory of Open Access Journals (Sweden)

    Kostić Dušan M.

    2004-01-01

    Full Text Available INTRODUCTION Renal artery aneurysms is relatively uncommon with reported incidence ranges from 0.3% to 1%. However, considering all visceral artery aneurysms the percentage of renal artery aneurysms is relatively high between 15-25%. The distal forms of renal artery aneurysms sometimes require "ex vivo" reconstruction and kidney autotransplantation. CASE REPORT A 75-year-old male presented with the right abdominal and back pain. He suffered from a long history of arterial hypertension and chronic renal failure over the last few months (urea blood = 19.8 mmol/l; creatinine = 198 mmol/l. Duplex ultrasonography showed abdominal aortic aneurysm. Subsequent translumbarangiography revealed juxtarenal abdominal aortic aneurysm associated with distal right renal artery aneurysm. The operation was performed under combined thoracic epidural analgesia and general anesthesia using transperitoneal approach. After the laparotomy, the ascending colon was mobilized and reflected medially followed by Kocher maneuver. The result was visualization of the anterior aspect of the right kidney, the collecting system, ureter as well as the right renal vein and artery with large saccular aneurysm located distally. After mobilization of the renal vessels and careful dissection of the ureter, the kidney was explanted. The operation was continued by two surgical teams. The first team performed abdominal aortic aneurysm resection and reconstruction with bifurcated Dacron graft. The second team performed ex vivo reparation of renal artery aneurysm. All time during the explantation, the kidney was perfused by Collins' solution. The saccular right renal artery aneurysm 4 cm in diameter was located at the kidney hilus at the first bifurcation. Three branches originated from the aneurysm. The aneurysm was resected completely. The longest and widest of three branches arising from the aneurysmal sac was end-to-end anastomized with 6 mm PTFE graft. After this intervention, one of

  11. Does the Ventrica magnetic vascular positioner (MVP) for coronary artery bypass grafting significantly alter local fluid dynamics? A numeric study.

    Science.gov (United States)

    Morbiducci, U; Lemma, M; Ponzini, R; Boi, A; Bondavalli, L; Antona, C; Montevecchi, F M; Redaelli, A

    2007-07-01

    Automatic devices have been recently introduced to make the anastomosis procedure quick and efficient when creating a coronary bypass on the beating heart. However, the implantation of these devices could modify the graft configuration, consistently affecting the hemodynamics usually found in the traditional anastomosis. As local fluid dynamics could play a significant role in the onset of vessel wall pathologies, in this article a computational approach was designed to investigate flow patterns in the presence of the Ventrica magnetic vascular positioner (Ventrica MVP) device. A model of standard hand-sewn anastomosis and of automated magnetic anastomosis were constructed, and the finite volume method was used to simulate in silico realistic graft hemodynamics. Synthetic analytical descriptors -- i.e., time-averaged wall shear stress (TAWSS), oscillating shear index (OSI) and helical flow index (HFI) -- were calculated and compared for quantitative assessment of the anastomosis geometry hemodynamic performance. In this case study, the same most critical region was identified for the 2 models as the one with the lowest TAWSS and the highest OSI (TAWSS=0.229, OSI=0.255 for the hand-sewn anastomosis; TAWSS=0.297, OSI=0.171 for the Ventrica MVP(R)). However, the shape of the Ventrica MVP does not induce more critical wall shear stresses, oscillating flow and damped helicity in the graft fluid dynamics, as compared with conventional anastomosis. We found that the use of the Ventrica MVP for the case study under investigation was not associated with more critical fluid dynamics than with conventional hand-sewn anastomosis. Thereby, the device could facilitate beating heart and minimally invasive coronary artery bypass grafting without increasing local hemodynamic-related risks of failure.

  12. Improved method for direct coronary grafting without CPB via anterolateral small thoracotomy

    NARCIS (Netherlands)

    Boonstra, PW; Grandjean, JG; Mariani, MA

    We describe an improved method of minimally invasive coronary artery bypass grafting that facilitates the anastomosis on the beating heart by means of a rigid and simple coronary stabilizer This technique permits anastomosis of the left internal mammary artery to the left anterior descending

  13. Is there a role for robotic totally endoscopic coronary artery bypass in patients with a colostomy?

    Science.gov (United States)

    Gibber, Marc; Lehr, Eric J; Kon, Zachary N; Wehman, P Brody; Griffith, Bartley P; Bonatti, Johannes

    2014-01-01

    Preoperative colostomy presents a significant risk of sternal wound complications, mediastinitis, and ostomy injury in patients requiring coronary artery bypass grafting. Less invasive procedures in coronary surgery have a potential to reduce the risk of sternal wound healing problems. Robotic totally endoscopic coronary artery bypass grafting in patients with a colostomy has not been reported. We describe a case of completely endoscopic coronary surgery using the da Vinci Si system in a patient with a transverse colostomy. Single left internal mammary artery grafting to the left anterior coronary artery was performed successfully on the beating heart. We regard this technique as the least invasive method of surgical coronary revascularization with a potential to reduce the risk of surgical site infection and mediastinitis in patients with a colostomy.

  14. The Etiology and Treatment of the Softened Phallus after the Radial Forearm Osteocutaneous Free Flap Phalloplasty

    Directory of Open Access Journals (Sweden)

    Seok-Kwun Kim

    2012-07-01

    Full Text Available BackgroundThe radial forearm osteocutaneous free flap is considered to be the standard technique for penile construction. One year after their operation, most patients experience a softened phallus, so that they suffer from difficulties in sexual intercourse. In this report, we present our experience with phalloplasty by radial forearm osteocutaneous free flap, as well as an evaluation of the etiology and treatment of the softened phallus.MethodsBetween March 2005 and February 2010, 58 patients underwent phalloplasty by radial forearm osteocutaneous free flap. Most of their neophallus had been softened subjectively and among them, 12 patients who wanted correction were investigated. We performed repetitive fat injection, artificial dermis grafting, silicone rod insertion, and rib bone with cartilaginous tip graft. Physical examination, plain radiograph, computed tomography, bone scintigraphy, and satisfaction scores were investigated.ResultsMost of the participants' penises have been softened after phalloplasty, and the skin elasticity had been also decreased. On plain radiograph, the distal end of the bone was self-rounded; however, the bone shape of the neophallus had no significant interval changes or resorption. Computed tomography showed equivocal density of cortical bone. On bone scintigraphy, the bone metabolism was active at 3 months postoperatively, and remained active 9 years postoperatively.ConclusionsThe use of a rib bone with cartilaginous tip graft could be an option for improvement of the softened phallus. Silicon rod insertion is also worth considering for rigidity of the softened phallus. Decreased rigidity due to soft tissue atrophy could be alleviated with repeated fat injection and artificial dermis grafting.

  15. Brachiomedian artery (arteria brachiomediana revisited: a comprehensive review

    Directory of Open Access Journals (Sweden)

    David Kachlik

    2016-03-01

    Full Text Available This article reviews in detail the superficial brachiomedian artery (arteria brachiomediana superficialis, a very rare variant of the main arterial trunks of the upper limb. It branches either from the axillary artery or the brachial artery, descends superficially in the arm (similar to the course of the superficial brachial artery and continues across the cubital fossa, runs superficially in the forearm, approaches the median nerve and enters the carpal canal to reach the hand. It usually terminates in the superficial palmar arch. The first drawing was published, in 1830, and the first description was published, in 1844. Altogether, to our knowledge, only 31 cases of a true, superficial brachiomedian artery have been reported (Some cases are incorrectly reported as superficial brachioradiomedian artery or superficial brachioulnomedian artery. Based on a meta-analysis of known, available studies, the incidence is 0.23% in Caucasians and 1.48% in Mongolians. Knowing whether or not this arterial variant is present is important in clinical medicine and relevant for: The catheterization via the radial or ulnar artery; harvesting the vascular pedicle for a forearm flap based on the radial, ulnar or superficial brachiomedian arteries; the possible collateral circulation in cases of the arterial closure; and the surgical management of carpal tunnel syndrome. Its presence can elevate the danger of an injury to the superficially located variant artery or of an accidental injection.

  16. Respiratory muscle stretch gymnastics in patients with post coronary artery bypass grafting pain: impact on respiratory muscle function, activity, mood and exercise capacity.

    Science.gov (United States)

    Aida, Nobuko; Shibuya, Masako; Yoshino, Katsuki; Komoda, Masaji; Inoue, Tomoko

    2002-12-01

    A new rehabilitation (New-RH) program including respiratory muscle stretch gymnastics (RMSG) was developed to alleviate post-coronary artery bypass grafting pain (PCP). Effects on respiratory muscle function, pain, activities of daily living (ADL), mood and exercise capacity were investigated. Subjects were 16 consecutive patients undergoing median full sternotomy coronary artery bypass grafting (CABG), and were randomly divided into equal New-RH (S-group) and conventional therapy (C-group) groups. Rib cage dominant breathing was observed postoperatively in both groups. With preoperative tan deltaVrc/deltaVab, increases at 1-week postoperatively and decreases at discharge for S-group tended to exceed those of C-group (p > .05). Decreased maximum inspiratory and expiratory pressure status for functional residual capacity and percent forced expiratory volume in one second at discharge again only tended to be smaller for S-group (p > .05). S-group displayed significantly reduced pain around both scapulas at discharge (p = .049), and increased mean overall ADL and profile of mood states (POMS)/Vigor scores (p = .031 and p = .018, respectively). POMS/Tension-Anxiety scores at discharge for S-group were significantly smaller than those preoperatively (p = .025), and S-group displayed significantly increased distance walked over 6-minutes at discharge than C-group (p = .029). New-RH improves patient participation in exercise therapy and increases exercise capacity by reducing PCP, relieving anxiety and tension, and improving ADL.

  17. Resveratrol combined with total flavones of hawthorn alleviate the endothelial cells injury after coronary bypass graft surgery.

    Science.gov (United States)

    Zhu, Ying; Feng, Bing; He, Songmin; Su, Zuqing; Zheng, Guangjuan

    2018-02-01

    To explore the preventive and therapeutic effects of Resveratrol combined with total flavones of hawthorn, compatibility of traditional Chinese medicines, on the endothelial cells injury after artery bypass graft surgery. The animal model of coronary artery bypass grafting (CABG) was prepared by transplanting a segment of autologous jugular vein onto the transected common carotid artery in rabbits. After CABG surgery, the rabbits were administrated with saline (model group), aspirin (Aspirin group), resveratrol (Res group), total flavones of hawthorn (Haw group) and resveratrol combined with total flavones of hawthorn (Res+Haw group) once a day for eight weeks, respectively. Eight weeks later, the grafting arteries from all group were obtained for the pathomorphism observation, peripheral blood was collected to detect circulating endothelial cells (CECs) by flow cytometry. And the concentration of albumen and mRNA of ICAM-1 in the serum were measured by western blot and quantitative real-time polymerase chain reaction, respectively. Compared with the model group, the level of CECs density and the expressions of albumen and mRNA of ICAM-1 were significantly decreased in the aspirin,resveratrol,total flavones of hawthorn and resveratrol combined with total flavones of hawthorn groups (P Resveratrol combined with total flavones of hawthorn could protect the endothelial cells after coronary artery bypass graft. Copyright © 2018 Elsevier GmbH. All rights reserved.

  18. [Flowmetric assessment of coronary bypass grafts in the conditions of artificial circulation and on the beating heart].

    Science.gov (United States)

    Bazylev, V V; Nemchenko, E V; Karnakhin, V A; Pavlov, A A; Mikulyak, A I

    2016-01-01

    Advantages and shortcomings of aortocoronary bypass grafting on the beating heart and in the conditions of artificial circulation (AC) have long been discussed. The data on patency of bypass grafts in the remote period are indicative of comparable results of operations with and without AC or advantages of using AC. In order to determine benefits of each method it is necessary to reveal intraoperative predictors of bypass grafts occlusion in the remote period. We analyzed the results of ultrasound flowmetry of the blood flow through the left internal thoracic artery during bypass grafting of the anterior descending artery with the use of AC and on the beating heart. A retrospective study included a total of 352 patients subdivided into 2 groups: Group One was composed of 120 patients undergoing surgery in the conditions of AC and Group Two comprised 232 patients subjected to similar operations on the beating heart. Blood flow was measured with the help of flowmeter VeryQ MediStim® after termination of AC and inactivation of heparin by protamine, with systolic pressure of 100-110 mm Hg. There were no statistically significant differences between the groups by the diameter and degree of stenosis of the anterior descending artery, diameter of the left internal thoracic artery. The mean volumetric blood flow velocity (Qmean) along the shunts in Group One was higher (p=0.01). No statistically significant differences by the pulsatility index (PI) between the groups were revealed (p=0.2). A conclusion was drawn that coronary bypass grafting of the anterior descending artery by the left internal thoracic artery in the conditions of artificial circulation made it possible to achieve higher volumetric velocity of blood flow through the conduit as compared with operations on the beating heart, with similar resistance index. The immediate results of the operations with the use of the both techniques did not differ.

  19. Topical application of sodium hyaluronate for preventing perivascular adhesion of the vein grafts in rabbits: An experimental study

    Directory of Open Access Journals (Sweden)

    Ming-ke GUO

    2017-10-01

    Full Text Available Objective To explore the effect of topical application of sodium hyaluronate on preventing perivascular adhesion of the vein grafts in rabbits. Methods Thirty-six male New Zealand white rabbits, aged 5 months, were randomly and equally divided into 2 groups: groups A and B. Arterial defect model was established by cutting about 1cm artery from the middle part of the dissected left common carotid artery. A section about 3cm was cut from the right external jugular vein, and the harvested vein was inverted and anastomosed end-to-end to the artery defect. After the anastomosis, the adventitia and two anastomoses of the grafted veins in group A were coated locally with 0.2ml sodium hyaluronate. The grafted veins were obtained 1, 2 and 4 weeks after the operation, with the perivascular adhesion of the vein grafts being examined macroscopically before the resection. HE staining and Masson staining were preformed for histological changes of grafted vein wall and the perivascular adhesion of the vein grafts. At 2, 4 weeks postoperation, the perivascular adhesions of the vein grafts were graded by the grading criteria of adhesion in macroscopic evaluation and histological evaluation. Results At 1, 2 and 4 weeks postoperatively, the macroscopic and histological observation found that the perivascular adhesions in group A were looser than those in group B. The macroscopic grade and histological grade were lower in group A than in group B, there was a significant difference between the two groups at 2 and 4 weeks postoperation (P<0.05. Conclusion Topical application of sodium hyaluronate can reduce the perivascular adhesion and is an ideal treatment strategy for preventing perivascular adhesion of vein grafts. DOI: 10.11855/j.issn.0577-7402.2017.08.14

  20. Aborted sudden cardiac death in a young male with anomalous left coronary artery arising from the pulmonary artery

    Directory of Open Access Journals (Sweden)

    Chih-Han Huang

    2017-01-01

    Full Text Available Anomalous left coronary artery arising from the pulmonary artery (ALCAPA is a rare type of congenital coronary abnormality that may be associated with early infant mortality and sudden adult cardiac death. We report a case regarding a 23-year-old male who collapsed during a marathon race and was resuscitated with cardiopulmonary resuscitation. Subsequent workups verified the diagnosis of ALCAPA. The patient underwent surgical intervention with obliteration of the ALCAPA orifice and coronary artery bypass grafting with left internal mammary artery to left anterior descending coronary artery. The procedure was done smoothly, and he was discharged uneventfully.

  1. A unique branching pattern of the axillary artery: a case report.

    Science.gov (United States)

    Bagoji, Ishwar B; Hadimani, Gavishiddappa A; Bannur, Balappa M; Patil, B G; Bharatha, Ambadasu

    2013-12-01

    During routine dissection classes for under graduate students, we found a unique and unusual case regarding the anomalous branching in the third part of the axillary artery was terminated into subscapular arterial trunk, superficial brachial artery and deep brachial artery. The subscapular arterial trunk was origin of several important arteries as the circumflex scapular, thoracodorsal, posterior circumflex humeral, thoraco-acromial and lateral thoracic arteries. The deep brachial artery in the arm gave anterior circumflex humeral artery at the surgical neck of humerus, which terminated in the cubital fossa by dividing into radial and ulnar arteries. The superficial brachial artery gave two profunda brachii arteries, both of which passed through spiral groove, along with radial nerve and three muscular branches, to brachialis muscle. This variation is very rare. As per our knowledge, we did not find any literature which explained variations which were similar to this. The normal and abnormal anatomy of the axillary region has practical importance among vascular radiologists and surgeons and it should be known for making an accurate diagnostic interpretation.

  2. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  3. Bilateral Internal Mammary Artery Utilization in Diabetics: Friend or Foe?

    Science.gov (United States)

    Crawford, Todd C; Zhou, Xun; Fraser, Charles D; Magruder, J Trent; Suarez-Pierre, Alejandro; Alejo, Diane; Bobbitt, Jennifer; Fonner, Clifford E; Wehberg, Kurt; Taylor, Brad; Kwon, Christopher; Fiocco, Michael; Conte, John V; Salenger, Rawn; Whitman, Glenn J

    2018-05-11

    Bilateral internal mammary artery (BIMA) grafting in diabetic patients undergoing coronary artery bypass grafting (CABG) remains controversial. Our study compared morbidity and mortality between 1)diabetic and non-diabetic BIMA patients and 2)diabetic BIMA versus diabetic patients who underwent left internal mammary artery (LIMA) grafting only. Patients who underwent isolated CABG from July 2011 - June 2016 at any of the 10 centers in Maryland were propensity scored across 16 variables. Diabetic BIMA were matched 1:1 by nearest neighbor matching to non-diabetic BIMA patients, and were separately matched 1:1 to diabetic LIMA patients. We calculated observed to expected (O/E) ratios for composite morbidity/mortality, operative mortality, unplanned reoperation, stroke, renal failure, prolonged ventilation, and deep sternal wound infection) and compared ratios among matched populations. Over the study period, 812 CABG patients received BIMA grafts, including 302 patients (37%) with diabetes. We matched 259 diabetic and non-diabetic BIMA patients. O/E ratios were higher in matched diabetic (vs non-diabetic) BIMA patients when comparing composite morbidity/mortality, reoperation, stroke, renal failure, and prolonged ventilation (all O/E>1.0), however, O/E for operative mortality was higher in non-diabetic BIMA patients. We additionally matched 292 diabetic BIMA to diabetic LIMA patients. Diabetic BIMA patients had a higher O/E for composite morbidity/mortality, operative mortality, stroke, renal failure, and prolonged ventilation. In this statewide analysis, diabetics who received BIMA grafts (compared to diabetics with LIMA grafts or non-diabetics with BIMA grafts) had higher O/E ratios for composite morbidity/mortality as a result of higher O/E ratios for major complications. Copyright © 2018. Published by Elsevier Inc.

  4. [Vascular trombosis of renal graft: 9 cases].

    Science.gov (United States)

    Kaaroud, Hayet; Béji, Soumaya; Ben Hamida, Fethi; Rais, Lamia; Ben Abdallah, Taieb; El Younsi, Fethi; Ben Moussa, Fatma; Abderrahim, Ezzedine; Bardi, Rafika; Ayed, Khaled; Chebil, Mohamed; Kheder, Adel

    2008-04-01

    Allograft renal thrombosis can occur in 1 to 6% of cases. Many predisposing factors has been identified especially alteration of coagulation. We analyzed in this study frequency and predisposing factors of renal graft thrombosis. We report a retrospective study including 319 renal transplant recipients. Nine patients (2.8%) presented veinous graft thrombosis in 5 cases and arterial thombosis in 4 cases. There were 6 men and 3 women aged of 30.6 years meanly (10-56) which developed the thrombosis 6 days (1-48) after the transplantation. All patients were detransplanted after 16.2 days and 1 patient died. Thrombosis constitute an important cause of graft loss. A perfect surgical technic and prophylactic treatment in high risk patients are necessary to reduce this complication.

  5. Biofabrication and testing of a fully cellular nerve graft

    International Nuclear Information System (INIS)

    Owens, Christopher M; Marga, Francoise; Forgacs, Gabor; Heesch, Cheryl M

    2013-01-01

    Rupture of a nerve is a debilitating injury with devastating consequences for the individual's quality of life. The gold standard of repair is the use of an autologous graft to bridge the severed nerve ends. Such repair however involves risks due to secondary surgery at the donor site and may result in morbidity and infection. Thus the clinical approach to repair often involves non-cellular solutions, grafts composed of synthetic or natural materials. Here we report on a novel approach to biofabricate fully biological grafts composed exclusively of cells and cell secreted material. To reproducibly and reliably build such grafts of composite geometry we use bioprinting. We test our grafts in a rat sciatic nerve injury model for both motor and sensory function. In particular we compare the regenerative capacity of the biofabricated grafts with that of autologous grafts and grafts made of hollow collagen tubes by measuring the compound action potential (for motor function) and the change in mean arterial blood pressure as consequence of electrically eliciting the somatic pressor reflex. Our results provide evidence that bioprinting is a promising approach to nerve graft fabrication and as a consequence to nerve regeneration. (paper)

  6. Interventional treatment of arterial complications in post renal transplantation

    International Nuclear Information System (INIS)

    Qian Xiaojun; Dai Dingke; Zhai Renyou

    2004-01-01

    Objective: To report our experience of interventional procedure for arterial complications in post renal transplantation and to evaluate its clinical value. Methods: In a retrospective analysis of renal transplantations in our center, 52 cases of renal allograft artery abnormalities had taken angiography. Interventional procedure included transluminal angioplasty of arterial stenoses, treatment of arterial occlusion, and embolization of pseudoaneurysm. Results: Renal allograft artery abnormalities included artery stenosis (n=21), artery thrombosis (n=13) and embolision (n=1), renal artery pseudoaneurysms (n=2), and decrease of renal artery flow (n=3). Of the 21 artery stenosis, 2 grafts with artery stenosis were lost because the stenosis could not be corrected, and 3 with mild stenosis received no treatment. Another 16 accepted renal artery angioplasty (balloon dilation, n=12, and stent implantation, n=4). 14 achieved long-term allograft function. 1 graft was lost because renal function failed to recover. Restenosis occurred in one stent implantation, and lost the allograft function after secondary dilation. 13 cases received thrombolytic therapy through artery catheter for thrombosis and 9 achieved long-term allograft function. Thrombolyses failed in 3 cases, and renal function failed to recover in 1 case. One pseudoaneurysm received stent implantation after embolization, and got a short-term allograft function. The other one received allograft excision. Conclusion: Intravascular interventional therapy will be the first-line therapy for any indications of complication in post renal transplantation, and it can surely save the kidney in a majority of instances. (authors)

  7. Cirurgia coronária com condutos arteriais múltiplos sem circulação extracorpórea Off-pump coronary artery bypass with multiple arterial conduits

    Directory of Open Access Journals (Sweden)

    Daniel Navia

    2005-03-01

    circulação extracorpórea utilizando condutos arteriais para a doença de múltiplos vasos é factível com baixa morbimortalidade em 30 dias.OBJECTIVE: To analyze intra-hospital results in patients undergoing elective off-pump total arterial revascularization and identify morbidity and mortality predictors using this surgical strategy. METHOD: From May 1999 to February 2004, 203 myocardial revascularization procedures with total arterial revascularization without cardiopulmonary bypass (off-pump were carried out in patients with multivessel disease (three vessels 81.7 %, one vessel disease was excluded. We report pre-surgical variables and co-morbidities: average age 63.9 ± 9.13 years, men 182 (89.5%, hypertension 132 (65%, smokers 125 (61%, hypercholesterolemia 152 (74.8%, previous myocardial infarction (> 30 days 73 (35%, moderate to severe ventricular dysfunction 31 (15%, redo five (2.5%. Total arterial revascularization included T-grafts and sequential grafts with left internal mammary (100%, right internal mammary (56.6% and radial (63% arteries. The total number of distal anastomosis was 576 (mean of three grafts/patient, all carried out with external mechanical stabilizers. There were no proximal aortic anastomoses. Conversion to on-pump surgery occurred in three (1.5% patients; 90% of the patients was extubated in the operating room. The multiple logistic regression test was used for statistical analysis. RESULTS: The postoperative incidence of atrial fibrillation was 12.8% (26, oligoanuric renal failure 3% (six, dialysis 0.49% (one, postoperative myocardial infarction 1.47% (three, low cardiac output 4% (eight, Redo for bleeding 1.47% (three, mediastinitis 1.47% (three, stroke 1.47% (three. Intra-hospital mortality was 2.45% (five. The only independent 30 day morbidity predictor was age (p=0.033; OR 1.04; IC 95%: 1-1.08. CONCLUSION: Off-pump myocardial revascularization with arterial conduits for multiple vessel disease is feasible with a low 30-day morbidity

  8. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    Science.gov (United States)

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  9. Midterm Experience of Ipsilateral Axillary-Axillary Arteriovenous Loop Graft as Tertiary Access for Haemodialysis

    Directory of Open Access Journals (Sweden)

    J. P. Hunter

    2014-01-01

    Full Text Available Objectives. To present a series of ipsilateral axillary artery to axillary vein loop arm grafts as an alternative vascular access procedure for haemodialysis in patients with difficult access. Design. Retrospective case series. Methods. Patients who underwent an axillary loop arteriovenous graft from September 2009 to September 2012 were included. Preoperative venous imaging to exclude central venous stenosis and to image arm/axillary veins was performed. A cuffed PTFE graft was anastomosed to the distal axillary artery and axillary vein and looped on the arm. Results. 25 procedures were performed on 22 patients. Median age was 51 years, with 9 males and 13 females. Median number of previous access procedures was 3 (range 0–7. Median followup was 16.4 months (range 1–35. At 3 months and 1 year, the primary and secondary patency rates were 70% and 72% and 36% and 37%, respectively. There were 11 radiological interventions in 6 grafts including 5 angioplasties and 6 thrombectomies. There were 19 surgical procedures in 10 grafts, including thrombectomy, revision, repair for bleeding, and excision. Conclusions. Our series demonstrates that the axillary loop arm graft yields acceptable early patency rates in a complex group of patients but to maintain graft patency required high rates of surgical and radiological intervention, in particular graft thrombectomy.

  10. 78. Coronary bypass using bilateral internal mammary arteries in an achondroplast

    Directory of Open Access Journals (Sweden)

    Mohamed Abdulwahab Alassal

    2015-10-01

    Full Text Available Coronary bypass grafting for ischemic heart disease in achondroplastic dwarfs is very rare. Shortage of veins and sometimes, inadequate vein quality can cause difficulties during surgery. Only two achondroplastic cases were reported in literature that underwent coronary bypass surgery, in which the left internal mammary artery and vein grafts were used. To the best of our knowledge using bilateral internal mammary arteries in such patients was not reported. We report here a 55 years old male achondroplastic dwarf who had triple vessels coronary disease that underwent successful coronary bypass surgery using bilateral mammary arteries. Anatomic and surgical challenges in achondroplasia are highlighted

  11. Vascularized bone grafting in a canine carpal avascular necrosis model

    NARCIS (Netherlands)

    Willems, Wouter F.; Alberton, Gregory M.; Bishop, Allen T.; Kremer, Thomas

    2011-01-01

    Limited experimental research has been performed on the treatment of avascular necrosis (AVN) by vascularized bone grafting. A new model simulating carpal AVN was created to investigate surgical revascularization of necrotic bone. In seven mongrel dogs, AVN was induced by removal of the radial

  12. Does topical tranexamic acid reduce postcoronary artery bypass graft bleeding?

    Directory of Open Access Journals (Sweden)

    Amir Mirmohammadsadeghi

    2018-01-01

    Full Text Available Background: Postoperative bleeding is a common problem in cardiac surgery. We tried to evaluate the effect of topical tranexamic acid (TA on reducing postoperative bleeding of patients undergoing on-pump coronary artery bypass graft (CABG surgery. Materials and Methods: One hundred and twenty-six isolated primary CABG patients were included in this clinical trial. They were divided blindly into two groups; Group 1, patients receiving 1 g TA diluted in 100 ml normal saline poured into mediastinal cavity before closing the chest and Group 2, patients receiving 100 ml normal saline at the end of operation. First 24 and 48 h chest tube drainage, hemoglobin decrease and packed RBC transfusion needs were compared. Results: Both groups were the same in baseline characteristics including gender, age, body mass index, ejection fraction, clamp time, bypass time, and operation length. During the first 24 h postoperatively, mean chest tube drainage in intervention group was 567 ml compared to 564 ml in control group (P = 0.89. Mean total chest tube drainage was 780 ml in intervention group and 715 ml in control group (P = 0.27. There was no significant difference in both mean hemoglobin decrease (P = 0.26 and packed RBC transfusion (P = 0.7. Topical application of 1 g TA diluted in 100 ml normal saline does not reduce postoperative bleeding of isolated on-pump CABG surgery. Conclusion: We do not recommend topical usage of 1 g TA diluted in 100 ml normal saline for decreasing blood loss in on-pump CABG patients.

  13. Untitled

    Indian Academy of Sciences (India)

    manufactured and tested as a replacement for the carotid artery in the dog. The graft is compliant in the longitudinal, circumferential and radial directions. It is anisotropic with compliances similar to those of the natural canine carotid artery. It is flexible, the inner blood contacting surface being smooth to the naked eye.

  14. A simultaneous minimally invasive approach to treat a patient with coronary artery disease and metastatic lung cancer.

    Science.gov (United States)

    Fu, Yuanhao; Zhang, Lufeng; Ji, Ling; Xu, Chenyang

    2016-01-01

    Concurrent lung cancer and coronary artery disease requiring treatment with percutaneous coronary intervention or coronary artery bypass grafting is not rare. An individualized perioperative anticoagulation regimen and minimal surgical trauma will benefit the patient's postoperative recovery. We successfully treated a 68-year-old female patient with a lesion in the left anterior descending artery and metastatic right lung carcinoma by simultaneous minimally invasive direct coronary artery bypass grafting via a small left thoracotomy and thoracoscopic wedge resection of the lung lesion. She recovered and was discharged on the eighth postoperative day. The patient showed no symptoms of myocardial ischemia postoperatively. Computed tomography scan did not indicate metastatic lesion of lung carcinoma at 1-year follow-up. In conclusion, minimally invasive direct coronary artery bypass grafting combined with thoracoscopic wedge resection is an effective minimally invasive treatment for concurrent lung cancer and coronary artery disease. This technique eliminates the risk of perioperative bleeding and provides satisfactory mid-term follow-up results.

  15. Fourier Analysis of Peripheral Blood Pressure and Flow in Intraoperative Assessment of Infrainguinal Arterial Reconstructions

    Directory of Open Access Journals (Sweden)

    Cheshmedzhiev Mihail V.

    2014-08-01

    Full Text Available AIM: To assess infrainguinal arterial reconstructions by intraoperative flowmetry under the distal anastomosis using a fast Fourier transformation; calculate and compare the amplitude ratios of peripheral arterial blood pressure and volume flow before and after drug-induced vasodilation of occluded bypass grafts and bypass grafts that have been patent at least for 1 year. To find what magnitude of the change of these ratios indicate a long-term patency of the bypass grafting. PATIENTS AND METHODS: We compared the results of the intraoperative flowmetry tests of 97 patients with infrainguinal arterial reconstructions. The patients were divided into two groups based on the graft status: the grafts in 49 patients were patent for at least a year, and 48 patients had failed bypass. We used a fast Fourier transform (FFT of the pressure and blood flow waves and compared the ratios of their amplitudes before and after administration of a vasodilator drug into the graft. Comparing the ratios obtained before and those after administration of the drug we quantified their change in each group and analysed them. RESULTS: After a drug-induced vasodilation, the blood pressure and flow amplitude ratios for the group with compromised reconstructions were less than 1.9 times smaller than those before drug infusion, while for the group with bypass grafts that had been functional for at least 12 months the ratios declined by more than 1.9≈2 times. CONCLUSION: The magnitude of the change of amplitude ratios of the peripheral pressure and volume flow after drug-induced vasodilation can be used to make an assessment of the bypass graft and the distal arterial segment.

  16. An anatomical study of variations in termination of brachial artery, with its embryological basis and clinical significance

    Directory of Open Access Journals (Sweden)

    Deepa T. K

    2016-03-01

    Full Text Available The brachial artery is the main artery of the arm. It begins as the continuation of 3rd part of axillary artery, at the level of inferior border of teres major muscle. It ends at the level of the neck of radius by dividing into radial and ulnar arteries. In the present study we found higher division of brachial artery at mid arm level into its terminal branches with superficial course of radial artery. The present study was done on 51 cadavers from our dept. of Anatomy. The upper limbs of the cadaver were dissected and observed for any variations in the branching pattern of brachial artery. In the present study, a total number of 51 cadaver’s, 102 upper limbs were studied. In one male cadaver we found bilateral higher division of brachial artery, trifurcation on left side and bifurcation on right side brachial artery, with superficial course of radial artery. The knowledge of variation in origin and course of brachial artery is useful for orthopaedicians, physicians, radiologist, vascular and plastic surgeons.

  17. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  18. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  19. Less Than Total Excision of Infected Prosthetic PTFE Graft Does Not Increase the Risk of Reinfection.

    Science.gov (United States)

    Sgroi, Michael D; Kirkpatrick, Vincent E; Resnick, Karen A; Williams, Russell A; Wilson, Samuel E; Gordon, Ian L

    2015-01-01

    Traditional treatment of infected polytetrafluoroethylene (PTFE) grafts consist of removal of the entire prosthesis. Closure of the native vessels may compromise vascular patency. We examined the outcomes for patients in whom a PTFE remnant of an infected graft was retained on the vessel. We reviewed the operating room log from 2000 to 2011 and identified all patients who had partial removal of an infected PTFE graft used for hemodialysis or peripheral bypass. These patients were examined for subsequent complications. Twenty-seven patients underwent 30 partial graft excisions with mean follow-up of 27 months. A total of 17% (5 of 30) of the partial graft resection procedures resulted in complications. Of 48 total remnants left behind at the arterial or venous anastomoses, reinfection occurred in 15%. Leaving a well-incorporated small 1-to 5-mm PTFE remnant at the arterial or venous anastomoses can be performed safely with a low risk of complications. © The Author(s) 2015.

  20. Identification of risk factors for vascular thrombosis may reduce early renal graft loss

    DEFF Research Database (Denmark)

    Keller, Anna Krarup; Jorgensen, Troels Munch; Jespersen, Bente

    2012-01-01

    of avoiding thrombotic events and saving thrombosed grafts. The incidence of arterial thrombosis was reported to 0.2-7.5% and venous thrombosis 0.1-8.2%, with the highest incidence among children and infants, and the lowest in living donor reports. The most significant risk factors for developing thrombosis...... were donor-age below 6 or above 60 years, or recipient-age below 5-6 years, per- or postoperative hemodynamic instability, peritoneal dialysis, diabetic nephropathy, a history of thrombosis, deceased donor, or >24 hours cold ischemia. Multiple arteries were not a risk factor, and a right kidney graft...