WorldWideScience

Sample records for radial artery figure

  1. Anomalies of radial and ulnar arteries

    Directory of Open Access Journals (Sweden)

    Rajani Singh

    Full Text Available Abstract During dissection conducted in an anatomy department of the right upper limb of the cadaver of a 70-year-old male, both origin and course of the radial and ulnar arteries were found to be anomalous. After descending 5.5 cm from the lower border of the teres major, the brachial artery anomalously bifurcated into a radial artery medially and an ulnar artery laterally. In the arm, the ulnar artery lay lateral to the median nerve. It followed a normal course in the forearm. The radial artery was medial to the median nerve in the arm and then, at the level of the medial epicondyle, it crossed from the medial to the lateral side of the forearm, superficial to the flexor muscles. The course of the radial artery was superficial and tortuous throughout the arm and forearm. The variations of radial and ulnar arteries described above were associated with anomalous formation and course of the median nerve in the arm. Knowledge of neurovascular anomalies are important for vascular surgeons and radiologists.

  2. Endoscopic Radial Artery Harvest for Coronary Artery Bypass Surgery

    Directory of Open Access Journals (Sweden)

    Kuan-Ming Chiu

    2006-01-01

    Conclusion: Endoscopic harvest of the radial artery is technically demanding, but excellent results can be achieved. The endoscopic approach can provide suitable conduits in a less invasive way than the open harvest technique.

  3. Intraluminal milrinone for dilation of the radial artery graft.

    Science.gov (United States)

    García-Rinaldi, R; Soltero, E R; Carballido, J; Mojica, J

    1999-01-01

    There is renewed interest in the use of the radial artery as a conduit for coronary artery bypass surgery. The radial artery is, however, a very muscular artery, prone to vasospasm. Milrinone, a potent vasodilator, has demonstrated vasodilatory properties superior to those of papaverine. In this report, we describe our technique of radial artery harvesting and the adjunctive use of intraluminal milrinone as a vasodilator in the preparation of this conduit for coronary artery bypass grafting. We have used these techniques in 25 patients who have undergone coronary artery bypass grafting using the radial artery. No hand ischemic complications have been observed in this group. Intraluminal milrinone appears to dilate and relax the radial artery, rendering this large conduit spasm free and very easy to use. We recommend the skeletonization technique for radial artery harvesting and the use of intraluminal milrinone as a radial artery vasodilator in routine myocardial revascularization. PMID:10524740

  4. Computer model analysis of the radial artery pressure waveform.

    Science.gov (United States)

    Schwid, H A; Taylor, L A; Smith, N T

    1987-10-01

    Simultaneous measurements of aortic and radial artery pressures are reviewed, and a model of the cardiovascular system is presented. The model is based on resonant networks for the aorta and axillo-brachial-radial arterial system. The model chosen is a simple one, in order to make interpretation of the observed relationships clear. Despite its simplicity, the model produces realistic aortic and radial artery pressure waveforms. It demonstrates that the resonant properties of the arterial wall significantly alter the pressure waveform as it is propagated from the aorta to the radial artery. Although the mean and end-diastolic radial pressures are usually accurate estimates of the corresponding aortic pressures, the systolic pressure at the radial artery is often much higher than that of the aorta due to overshoot caused by the resonant behavior of the radial artery. The radial artery dicrotic notch is predominantly dependent on the axillo-brachial-radial arterial wall properties, rather than on the aortic valve or peripheral resistance. Hence the use of the radial artery dicrotic notch as an estimate of end systole is unreliable. The rate of systolic upstroke, dP/dt, of the radial artery waveform is a function of many factors, making it difficult to interpret. The radial artery waveform usually provides accurate estimates for mean and diastolic aortic pressures; for all other measurements it is an inadequate substitute for the aortic pressure waveform. In the presence of low forearm peripheral resistance the mean radial artery pressure may significantly underestimate the mean aortic pressure, as explained by a voltage divider model.

  5. Anomalous Medial Branch of Radial Artery: A Rare Variant

    Directory of Open Access Journals (Sweden)

    Surbhi Wadhwa

    2016-10-01

    Full Text Available Radial artery is an important consistent vessel of the upper limb. It is a useful vascular access site for coronary procedures and its reliable anatomy has resulted in an elevation of radial forearm flaps for reconstructive surgeries of head and neck. Technical failures, in both the procedures, are mainly due to anatomical variations, such as radial loops, ectopic radial arteries or tortuosity in the vessel. We present a rare and a unique anomalous medial branch of the radial artery spiraling around the flexor carpi radialis muscle in the forearm with a high rising superficial palmar branch of radial artery. Developmentally it probably is a remanent of the normal pattern of capillary vessel maintenance and regression. Such a case is of importance for reconstructive surgeons and coronary interventionists, especially in view of its unique medial and deep course.

  6. Pseudoaneurysm of the Radial Artery After a Bicycle Fall.

    Science.gov (United States)

    Ratschiller, Thomas; Müller, Hannes; Schachner, Thomas; Zierer, Andreas

    2018-07-01

    We report a case of a 64-year-old man who developed a painful pulsatile mass in the distal forearm after a bicycle fall with fracture of the wrist. Ultrasonography confirmed a 2.5-cm large pseudoaneurysm of the radial artery. The patient underwent surgical exploration. The pseudoaneurysm was resected and the defect in the arterial wall was reconstructed with an autologous saphenous vein patch. We suggest that the double arterial supply of the hand should be preserved whenever possible.

  7. Sharp Dissection versus Electrocautery for Radial Artery Harvesting

    Science.gov (United States)

    Marzban, Mehrab; Arya, Reza; Mandegar, Mohammad Hossein; Karimi, Abbas Ali; Abbasi, Kiomars; Movahed, Namvar; Abbasi, Seyed Hesameddin

    2006-01-01

    Radial arteries have been increasingly used during the last decade as conduits for coronary artery revascularization. Although various harvesting techniques have been described, there has been little comparative study of arterial damage and patency. A radial artery graft was used in 44 consecutive patients, who were randomly divided into 2 groups. In the 1st group, the radial artery was harvested by sharp dissection and in the 2nd, by electrocautery. These groups were compared with regard to radial artery free flow, harvest time, number of clips used, complications, and endothelial damage. Radial artery free flow before and after intraluminal administration of papaverine was significantly greater in the electrocautery group (84.3 ± 50.7 mL/min and 109.7 ± 68.5 mL/min) than in the sharp-dissection group (52.9 ± 18.3 mL/min and 69.6 ± 28.2 mL/ min) (P =0.003). Harvesting time by electrocautery was significantly shorter (25.4 ± 4.3 min vs 34.4 ± 5.9 min) (P =0.0001). Electrocautery consumed an average of 9.76 clips, versus 22.45 clips consumed by sharp dissection. The 2 groups were not different regarding postoperative complications, except for 3 cases of temporary paresthesia of the thumb in the electrocautery group; histopathologic examination found no endothelial damage. We conclude that radial artery harvesting by electrocautery is faster and more economical than harvesting by sharp dissection and is associated with better intraoperative flow and good preservation of endothelial integrity. PMID:16572861

  8. Correlation of femoral artery vs radial artery pressures with central pressure after cardiopulmonary bypass in children

    International Nuclear Information System (INIS)

    Yaseen, R.; Memon, H.

    2008-01-01

    To assess the effectiveness of femoral and radial arterial lines on the correlation of peripheral and central mean arterial blood pressure in children after discontinuation of cardiopulmonary bypass. Fifty children scheduled for cardiac surgery with cardiopulmonary bypass were included in the study. After approval from the hospital ethics committee and informed consent. 50 children undergoing cardiac surgical procedures with cardiopulmonary bypass were randomly assigned to two different groups. In Group- A (RAP, n-2) a radial arterial line and in Group-B (FAP, n-25) a femoral arterial line was used to monitor the blood pressure. Simultaneous mean peripheral arterial pressure and mean central aortic pressure were recorded before cardiopulmonary bypass and 5 mins after separation from the cardiopulmonary bypass. The correlation of mean peripheral arterial pressure (radial and femoral) versus mean aortic pressure were compared. The data was recorded as Mean +- SD and P-value. The ages of children ranged from 4-12 years and their weight from 14.1-28.5 kg. In all of them following cardiopulmonary bypass, aortic pressure correlates better with femoral arterial pressure (p<0.001). The radial arterial line readings under estimated central aortic pressure when compared to femoral arterial line readings. Aortic pressure readings correlate better with femoral arterial pressure than radial arterial pressure in children. (author)

  9. Rare high origin of the radial artery: a bilateral, symmetrical case ...

    African Journals Online (AJOL)

    Arterial variations in the upper limb can occur at the level of the axillary, brachial, radial and ulnar arteries as well as the palmar arches. This is a report of bilateral, symmetrical high origin of the radial artery from the axillary artery. Knowledge of such variations is important in vascular and reconstructive surgery. (Nig J Surg ...

  10. Long-term outcomes of internal carotid artery disease treated using radial artery graft

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Umeoka, Katsuya; Tateyama, Kojiro

    2009-01-01

    Complex internal carotid artery disease presents a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict occurrence of ischemic complications after internal carotid artery ligation. The present study concerns long-term clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2007, we performed radial artery grafting followed immediately by parent artery occlusion in 20 sides of 19 patients with complex internal carotid arteries disease with follow-up for more than 36 months (5 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative MRI and MR angiography (MRA) every year to assess graft patency, ischemic complications, and de novo aneurysm. Another 20 carotid aneurysms with visual disturbance were assessed concerning outcome. Among 13 patients with cranial nerve (III and VI) disturbances, all dysfunctions were improved in cases treated within 8 months of onset to operation. On the other hand, patients with second cranial nerve disturbances were not improved in cases treated after 4 months of onset. No long-term complications were discovered with MRI and MRA. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Long-term safety is satisfactory, with no delayed complications such as graft stenosis, ischemic complications or de novo aneurysm formations in follow-up periods of more than 3 years. Good clinical outcome of cranial nerve palsy was achieved in patients treated within 8 months of onset for cranial nerve (CN) III and VI, and 4 of CN II palsy. (author)

  11. Endoscopic versus open radial artery harvest and mammario-radial versus aorto-radial grafting in patients undergoing coronary artery bypass surgery

    DEFF Research Database (Denmark)

    Carranza, Christian L; Ballegaard, Martin; Werner, Mads U

    2014-01-01

    the postoperative complications will be registered, and we will evaluate muscular function, scar appearance, vascular supply to the hand, and the graft patency including the patency of the central radial artery anastomosis. A patency evaluation by multi-slice computer tomography will be done at one year...... to aorto-radial revascularisation techniques but this objective is exploratory. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT01848886.Danish Ethics committee number: H-3-2012-116.Danish Data Protection Agency: 2007-58-0015/jr.n:30-0838....

  12. Radial artery approach for coronary intervention - early experience

    International Nuclear Information System (INIS)

    Jan, H.; Hadi, A.; Fahim, M.; Gul, A.M.; Irfan, M.; Khan, S.B.; Hafizullah, M.

    2012-01-01

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  13. Radial artery approach for coronary intervention - early experience

    Energy Technology Data Exchange (ETDEWEB)

    Jan, H; Hadi, A; Fahim, M; Gul, A M; Irfan, M; Khan, S B; Hafizullah, M [Lady Reading Hospital and Khyber Medical University, Peshawar (Pakistan). Dept. of Cardiology

    2012-01-15

    Objective: To see the clinical outcome of patients undergoing Transradial Coronary Angioplasty with stable Angina. Methodology: This was a single center observational study with prospective data collection of 338 patients who underwent transradial coronary angioplasty from September 2009 to August 2011, at Post Graduate Medical Institute, Lady Reading Hospital, Peshawar. Patients of both genders and all ages who had transradial coronary angioplasty for chronic stable angina were included in the study. Patients were clinically examined in out patients department on first month of hospital discharge and clinical outcome data was recorded. Results: A total of 338 patients were included in the study. Male were 58.8% and 41.2% were female with mean age of 52+-7 years. All the patients had coronary intervention through right radial artery. Baseline characteristics of the patients were; 48.2% diabetic, 43.2% hypertensive, 30.5% smokers, dyslipidemia was 45.7% and mean values of serum creatinine and Hemoglobin were 1.1+-0.3 and 11.5+-1.5, respectively. The frequency of various complications were as follow; hematoma 1.3%, nausea and vomiting 2.2%, pain in hand 11.2%, re admission to hospital for chest pain 6.5%, need for revascularization 2.2%, hand ischemia 1.8%, minor bleeding 0.9%, no major bleeding and 1.9% mortality. Conclusion: The radial artery approach for coronary intervention is useful with low degree of access site vascular complications and an early mobilization. (author)

  14. Radial artery spasm occurred in transradial coronary intervention for coronary heart disease: its occurrence and predictors

    International Nuclear Information System (INIS)

    Zhong Jiming; Li Lang; Lu Yongguang; Zeng Shuyi

    2011-01-01

    Objective: To discuss the incidence and clinical predictors of radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease. Methods: A total of 1020 patients, who underwent transradial coronary procedures for coronary heart disease during the period of May 2007 Jan 2010 in authors' hospital, were enrolled in this study. All clinical information and medication were recorded in detail. Arteriography via radial artery was performed in all patients. The diameter of the radial artery as well as the arterial anatomy, including arterial variations, were determined and observed, which was follow by coronary angiography or percutaneous coronary intervention. Multivariate Logistic regression analysis was adopted to evaluate the variables, such as clinical parameters, angiographic characteristics of the radial artery and procedure-related factors, in predicting the occurrence of radial artery spasm. Results: Radial artery spasm occurred in 209 (20.5%) patients. Multivariate Logistic regression analysis showed that the following eight factors were independently associated with the occurrence of radial artery spasm. These factors were as follows: female gender (OR=2.8, 95% CI 2.5-5.8; P=0.001), age (OR=0.68, 95% CI 0.60-0.92; P=0.003), smoking (OR=2.3, 95% CI 1.8-4.1; P=0.026), moderate-to-severe pain of forearm during radial artery cannulation (OR=3.0, 95% CI 2.3-4.8; P=0.006), radial artery anatomical abnormalities (OR=4.7, 95% CI 3.6-7.2; P=0.002), the ratio of radial artery diameter to patient's height (RAH) (OR=5.2, 95% CI 3.7-8.1; P=0.012), the ratio of radial artery diameter to outer diameter of the sheath (RAOD) (OR=5.8, 95% CI 4.2-6.9; P=0.006) and the number of catheter exchange (OR=2.3, 95% CI 1.4-4.3; P=0.038). Conclusion: Radial artery spasm occurred in performing transradial coronary intervention for coronary heart disease is frequently seen in clinical practice. Female gender, younger age, smoking, forearm pain during

  15. Optimal management of radial artery grafts in CABG: Patient and target vessel selection and anti-spasm therapy.

    Science.gov (United States)

    Schwann, Thomas A; Gaudino, Mario; Baldawi, Mustafa; Tranbaugh, Robert; Schwann, Alexandra N; Habib, Robert H

    2018-05-01

    The current literature on radial artery grafting is reviewed focusing on the optimal deployment of radial artery grafts in coronary artery bypass surgery with specific attention to the selection of patients and target vessels for radial artery grafting. © 2018 Wiley Periodicals, Inc.

  16. Utility of the puncture of the radial artery in interventionist radiology

    International Nuclear Information System (INIS)

    Triana Rodriguez, Carlos Eduardo; Montes S, Mauricio; Barragan F, Jaime; Ucros Diaz Pablo; Ucros Diaz, Ignacio; Castillo, Luis Fernando

    1998-01-01

    We present the radial artery access, previous evaluation of collateral circulation with Allen's Test, as an alternative vascular access in patients with contraindications for femoral or axillary approaches. The radial artery puncture offers advantages, such as diminished bleeding and hematoma formation

  17. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    International Nuclear Information System (INIS)

    Stark, Christopher; Olsen, Daniel; Morris, Christopher; Bertges, Daniel; Najarian, Kenneth

    2016-01-01

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  18. Intravascular Papillary Endothelial Hyperplasia (Masson’s Tumor) of the Radial Artery: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    Stark, Christopher, E-mail: Christopher.stark@uvmhealth.org [University of Vermont Medical Center, Department of Radiology (United States); Olsen, Daniel [Mayo Clinic, Department of Pathology (United States); Morris, Christopher [University of Vermont Medical Center, Department of Radiology (United States); Bertges, Daniel [University of Vermont Medical Center, Department of Surgery (United States); Najarian, Kenneth [University of Vermont Medical Center, Department of Radiology (United States)

    2016-11-15

    Intravascular papillary endothelial hyperplasia (IPEH), often referred to as Masson’s tumor, is a benign non-neoplastic vascular lesion of the skin and subcutaneous tissues. Although it is rare, knowledge of the existence of IPEH is important as it can mimic other benign and malignant tumors, most notably angiosarcoma. IPEH remains an incompletely understood entity; however, most consider it to be the result of reactive endothelial proliferation following thrombus formation within a vessel, vascular malformation, or adjacent to a vessel. In this article, we report a case of IPEH arising within an arteriovenous malformation of the radial artery and present accompanying multimodality imaging and pathology figures. We will also describe the clinical presentation, pathophysiology, histology, imaging features, and management of IPEH.

  19. Aneurisma idiopático de artéria radial: relato de caso Idiopathic radial artery aneurysm: case report

    Directory of Open Access Journals (Sweden)

    Luiz Ernani Meira Jr.

    2011-12-01

    Full Text Available Os aneurismas da artéria radial são extremamente raros. Em sua maioria, consistem de pseudoaneurismas pós-traumáticos. Os aneurismas da artéria radial verdadeiros podem ser idiopáticos, congênitos, pós-estenóticos ou associados a patologias, tais como vasculites e doenças do tecido conjuntivo. Foi relatado um caso de aneurisma idiopático de artéria radial em uma criança de três anos, que, após completa investigação diagnóstica complementar, foi submetida à ressecção cirúrgica.Radial artery aneurysms are extremely rare. Post-traumatic pseudoaneurysms are the vast majority. True radial artery aneurysms can be idiopathic, congenital, poststenotic, or associated with some pathologies, such as vasculitis and conjunctive tissue diseases. We report a case of an idiopathic aneurysm of the radial artery in a three-year-old child who was submitted to surgical resection after a complete diagnostic approach.

  20. Treatment of complex internal carotid artery aneurysms using radial artery grafts. Surgical technique, perioperative complications, and results in 17 patients

    International Nuclear Information System (INIS)

    Murai, Yasuo; Teramoto, Akira; Mizunari, Takayuki; Kobayashi, Shiro; Kamiyama, Hiroyasu

    2007-01-01

    Complex giant or large internal carotid artery aneurysms present a surgical challenge because limitations and difficulty are encountered with either clipping or endovascular treatment. Our review of previous reports suggests that no current vascular assessment can accurately predict the occurrence of ischemic complications after internal carotid artery ligation. The present study concerns surgical technique, complications, and clinical outcome of radial artery grafting followed by parent artery trapping or proximal occlusion for management of these difficult lesions. Between September 1997 and October 2005, we performed radial artery grafting followed immediately by parent artery occlusion in 17 patients with giant or large complex intracranial carotid aneurysms (3 men, 14 women; mean follow-up duration, 62 months). All patients underwent postoperative digital subtraction angiography to assess graft patency and aneurysm obliteration. All 17 aneurysms were excluded from the cerebral circulation, with all radial artery grafts patent. Among 4 patients with cranial nerve disturbances, dysfunction was temporary in 5; in the others, oculomotor nerve paresis persisted. No perioperative cerebral infarction occurred. Sensory aphasia reflecting cerebral contusions caused by temporal lobe retraction resolved within 2 months, as did hemiparesis from a postoperative epidural hematoma. With appropriate attention to surgical technique, radial artery grafting followed by acute parent artery occlusion is a safe treatment for complex internal carotid artery aneurysms. Graft patency and aneurysm thrombosis were achieved in all patients. Cranial nerve dysfunction (III, VI) caused by altered blood flow from the internal carotid artery after occlusion was the most common complication and typically was temporary. In our experience with these difficult aneurysms, not only clipping but also reconstruction of the internal carotid artery was required, especially for wide-necked symptomatic

  1. Analysis of linguistic terms of variables representing the wave of arterial diameter variation in radial arteries using fuzzy entropies

    International Nuclear Information System (INIS)

    Nuno Almirantearena, F; Introzzi, A; Clara, F; Burillo Lopez, P

    2007-01-01

    In this work we use 53 Arterial Diameter Variation (ADV) waves extracted from radial artery of normotense males, along with the values of variables that represent the ADV wave, obtained by means of multivariate analysis. Then, we specify the linguistic variables and the linguistic terms. The variables are fuzzified using triangular and trapezoidal fuzzy numbers. We analyze the fuzziness of the linguistic terms by applying discrete and continuous fuzzy entropies. Finally, we infer which variable presents the greatest disorder associated to the loss of arterial elasticity in radial artery

  2. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    Energy Technology Data Exchange (ETDEWEB)

    Joshi, Abhay B. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Kalange, Ashok E. [Department of Electronic Science, University of Pune, Pune 411 007 (India); Tuljaram Chaturchand College, Baramati 413 102 (India); Bodas, Dhananjay, E-mail: dhananjay.bodas@gmail.co [Center for Nanobio Sciences, Agharkar Research Institute, Pune 411 004 (India); Gangal, S.A. [Department of Electronic Science, University of Pune, Pune 411 007 (India)

    2010-04-15

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  3. Simulations of piezoelectric pressure sensor for radial artery pulse measurement

    International Nuclear Information System (INIS)

    Joshi, Abhay B.; Kalange, Ashok E.; Bodas, Dhananjay; Gangal, S.A.

    2010-01-01

    A radial artery pulse is used to diagnose human body constitution (Prakruti) in Ayurveda. A system consisting of piezoelectric sensor (22 mm x 12 mm), data acquisition card and LabView software was used to record the pulse data. The pulse obtained from the sensor was noisy, even though signal processing was done. Moreover due to large sized senor accurate measurements were not possible. Hence, a need was felt to develop a sensor of the size of the order of finger tip with a resonant frequency of the order of 1 Hz. A micromachined pressure sensor based on piezoelectric sensing mechanism was designed and simulated using CoventorWare. Simulations were carried out by varying dimensions of the sensor to optimize the resonant frequency, stresses and voltage generated as a function of applied pressure. All simulations were done with pressure ranging of 1-30 kPa, which is the range used by Ayurvedic practitioners for diagnosis. Preliminary work on fabrication of such a sensor was carried out successfully.

  4. Figures

    Data.gov (United States)

    U.S. Environmental Protection Agency — data for figures 1-8 in journal article "Assessment of port-related air quality impacts: geographic analysis of population", International Journal of Environment and...

  5. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    OpenAIRE

    Jun, Min-Ho; Kim, Young-Min; Bae, Jang-Han; Jung, Chang Jin; Cho, Jung-Hee; Jeon, Young Ju

    2016-01-01

    The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB) as one of the s...

  6. Radial Artery as a Coronary Artery Bypass Conduit: 20-Year Results.

    Science.gov (United States)

    Gaudino, Mario; Tondi, Paolo; Benedetto, Umberto; Milazzo, Valentina; Flore, Roberto; Glieca, Franco; Ponziani, Francesca Romana; Luciani, Nicola; Girardi, Leonard N; Crea, Filippo; Massetti, Massimo

    2016-08-09

    There is a lack of evidence for the choice of the second conduit in coronary surgery. The radial artery (RA) is a possible option, but few data on very-long-term outcomes exist. This study describes 20-year results of RA grafts used for coronary artery bypass grafting and the effects of RA removal on forearm circulation. We report the results of the prospective 20-year follow-up of the first 100 consecutive patients who received the RA as a coronary bypass conduit at our institution. Follow-up was 100% complete. There were 64 deaths, 23 (35.9%) from cardiovascular causes. Kaplan-Meier 20-year survival was 31%. Of the 36 survivors, 33 (91.6%) underwent RA graft control at a mean of 19.0 ± 2.5 years after surgery. The RA was found to be patent in 24 cases (84.8% patency). In the overall population, probability of graft failure at 20 years was 19.0 ± 0.2% for the left internal thoracic artery (ITA), 25.0 ± 0.2% for the RA, and 55.0 ± 0.2% for the saphenous vein (p = 0.002 for RA vs. saphenous vein, 0.11 for RA vs. ITA, and p 90%, but not location of distal anastomosis, significantly influenced long-term RA graft patency. No patients reported hand or forearm symptoms. The ulnar artery diameter was increased in the operated arm (2.44 ± 0.43 mm vs. 2.01 ± 0.47 mm; p 90% stenosis. RA harvesting does not lead to hand or forearm symptoms, even at a very-long-term follow-up. Copyright © 2016 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  7. Pre-ejection period by radial artery tonometry supplements echo doppler findings during biventricular pacemaker optimization

    Directory of Open Access Journals (Sweden)

    Qamruddin Salima

    2011-07-01

    Full Text Available Abstract Background Biventricular (Biv pacemaker echo optimization has been shown to improve cardiac output however is not routinely used due to its complexity. We investigated the role of a simple method involving computerized pre-ejection time (PEP assessment by radial artery tonometry in guiding Biv pacemaker optimization. Methods Blinded echo and radial artery tonometry were performed simultaneously in 37 patients, age 69.1 ± 12.8 years, left ventricular (LV ejection fraction (EF 33 ± 10%, during Biv pacemaker optimization. Effect of optimization on echo derived velocity time integral (VTI, ejection time (ET, myocardial performance index (MPI, radial artery tonometry derived PEP and echo-radial artery tonometry derived PEP/VTI and PEP/ET indices was evaluated. Results Significant improvement post optimization was achieved in LV ET (286.9 ± 37.3 to 299 ± 34.6 ms, p Conclusion An acute shortening of PEP by radial artery tonometry occurs post Biv pacemaker optimization and correlates with improvement in hemodynamics by echo Doppler and may provide a cost-efficient approach to assist with Biv pacemaker echo optimization.

  8. High Origin of Radial Arteries: A Report of Two Rare Cases

    Directory of Open Access Journals (Sweden)

    Dong Zhan

    2010-01-01

    Full Text Available Variations in the arterial supply of the upper limb are relatively common, with reported prevalence rates ranging from 11 to 24.4%. Of these, the most commonly encountered variation in the arm is a high origin of the radial artery. However, after consecutively dissecting and examining 600 Singaporean Chinese cadavers (1,200 upper limbs, we found only two cases of this. In both cases, the brachioradial artery originated from the upper one-third of the brachial artery and continued distally as the radial artery in the forearm. The local prevalence of 0.33% of this variation is significantly lower compared against populations from other geographical regions. Although rare, recognition of the variation is of fundamental importance to clinical practice.

  9. Radiation exposure and patient experience during percutaneous coronary intervention using radial and femoral artery access

    International Nuclear Information System (INIS)

    Geijer, Haakan; Persliden, Jan

    2004-01-01

    The aim of this study was to evaluate radiation dose and patient discomfort/pain in radial artery access vs femoral artery access in percutaneous coronary intervention (PCI). Dose-area product (DAP) was measured non-randomised for 114 procedures using femoral access and for 55 using radial access. The patients also responded to a questionnaire concerning discomfort and pain during and after the procedure. The mean DAP was 69.8 Gy cm 2 using femoral access and 70.5 Gy cm 2 using radial access. Separating the access site from confounding factors with a multiple regression, there was a 13% reduction in DAP when using radial access (p=0.038). Procedure times did not differ (p=0.81). Bed confinement was much longer in the femoral access group (448 vs 76 min, p=0.000). With femoral access, there was a significantly higher patient grading for chest (p=0.001) and back pain (p=0.003) during the procedure and for access site (p=0.000) and back pain (p=0.000) after the procedure. Thirty-two femoral access patients (28%) were given morphine-type analgesics in the post-procedure period compared to three radial access patients (5%, p=0.001). DAP does not increase when using radial instead of femoral access and the patients grade discomfort and pain much lower when using radial access. Radial access is thus beneficial to use. (orig.)

  10. Intra-arterial vasodilators to prevent radial artery spasm: a systematic review and pooled analysis of clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Kwok, Chun Shing, E-mail: shingkwok@doctors.org.uk [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Rashid, Muhammad [St. Helens & Knowsley Teaching Hospital (NHS) Trust, Whiston Hospital, Prescot (United Kingdom); Fraser, Doug [Manchester Heart Centre, Manchester Royal Infirmary (United Kingdom); Nolan, James [University Hospital of North Midlands, Stoke-on-Trent (United Kingdom); Mamas, Mamas [Keele Cardiovascular Research Group, Keele University, Stoke-on-Trent (United Kingdom); Farr Institute, Institute of Population Health, University of Manchester, Manchester (United Kingdom)

    2015-12-15

    Objectives: The aim of this study is to review the available literature on the efficacy and safety of agents used for prevention of RAS. Background: Different vasodilator agents have been used to prevent radial artery spasm (RAS) in patients undergoing transradial cardiac catheterization. Methods: We included studies that evaluated any intra-arterial drug administered in the setting cardiac catheterization that was undertaken through the transradial access site (TRA). We also compared studies for secondary outcomes of major bleeding, procedure time, and procedure failure rate in setting of RAS prevention, patent hemostasis and radial artery occlusion. Results: 22 clinical studies met the inclusion criteria. For placebo, RAS rate was 12% (4 studies, 638 participants), which was similar to 2.5 mg of verapamil 12% (3 studies, 768 participants) but greater than 5 mg of verapamil (4%, 2 studies, 497 participants). For nicorandil, there was a much higher RAS rate compared to placebo (16%, 3 studies, 447 participants). The lowest rates of RAS was found for nitroglycerin at both 100 μg (4%) and 200 μg (2%) doses, isosorbide mononitrate (4%) and nicardipine (3%). We found no information regarding the procedure failure rates, patent hemostasis, and radial artery occlusion in these studies. Conclusions: In this largest and up-to-date review on intra-arterial vasodilators use to reduce RAS, we have found that the verapamil at a dose of 5 mg or verapamil in combination with nitroglycerine are the best combinations to reduce RAS. - Highlights: • Radial artery spasm (RAS) causes procedural failure in transradial catheterization. • RAS may complicate 10–15% procedures undertaken through the radial approach. • We reviewed the efficacy of vasodilators that have been used to minimize RAS. • The pooled RAS rate was lowest with 5 mg of verapamil (4%) compared to placebo (12%). • The best combination of drugs to minimize RAS is nitroglycerine and verapamil.

  11. Radial motion of the carotid artery wall: A block matching algorithm approach

    Directory of Open Access Journals (Sweden)

    Effat Soleimani

    2012-06-01

    Full Text Available Introduction: During recent years, evaluating the relation between mechanical properties of the arterialwall and cardiovascular diseases has been of great importance. On the other hand, motion estimation of thearterial wall using a sequence of noninvasive ultrasonic images and convenient processing methods mightprovide useful information related to biomechanical indexes and elastic properties of the arteries and assistdoctors to discriminate between healthy and diseased arteries. In the present study, a block matching basedalgorithm was introduced to extract radial motion of the carotid artery wall during cardiac cycles.Materials and Methods: The program was implemented to the consecutive ultrasonic images of thecommon carotid artery of 10 healthy men and maximum and mean radial movement of the posterior wall ofthe artery was extracted. Manual measurements were carried out to validate the automatic method andresults of two methods were compared.Results: Paired t-test analysis showed no significant differences between the automatic and manualmethods (P>0.05. There was significant correlation between the changes in the instantaneous radialmovement of the common carotid artery measured with the manual and automatic methods (withcorrelation coefficient 0.935 and P<0.05.Conclusion: Results of the present study showed that by using a semi automated computer analysismethod, with minimizing the user interfere and no attention to the user experience or skill, arterial wallmotion in the radial direction can be extracted from consecutive ultrasonic frames

  12. Reliability of palpation of the radial artery compared with auscultation of the brachial artery in measuring SBP

    NARCIS (Netherlands)

    van der Hoeven, Niels V.; van den Born, Bert-Jan H.; van Montfrans, Gert A.

    2011-01-01

    Background Systolic blood pressure contributes more to cardiovascular disease than DBP, especially in elderly persons. Palpation of the radial artery to assess SBP - Riva-Rocci's technique-may be an attractive alternative for auscultatory SBP in these patients. Therefore, we investigated the

  13. PROLONGED RADIAL ARTERY SPASM IN THE CATHETERIZATION LABORATORY - RELIEF BY PHARMACOLOGICAL INTERVENTION

    Directory of Open Access Journals (Sweden)

    Krishna Kumar

    2010-11-01

    Full Text Available Radial spasm is often very prolonged and painful to the patient. Here, we describe a novel way to deal with the same. The total spasm lasted over 4 hours. A 3.4 6 JR catheter was introduced via the femoral route and papav arine one ampoule was injected directly into the right subclavian artery. After about 10 min we were able to pull out the radial catheter. Radial angiography is a simple procedure with reportedly less complications 1,2. How ever ,it has one major complication radial spasm. We describe here a patient with radial spasm that persisted for more than 2 hours and how we dealt with it.

  14. [Digital necrosis in a patient with anorexia nervosa. Association of vasculopathy and radial artery injury].

    Science.gov (United States)

    Launay, D; Queyrel, V; Hatron, P Y; Michon-Pasturel, U; Hachulla, E; Devulder, B

    2000-11-13

    Patients with anorexia nervosa can develop distal vasculopathy sometimes leading to severe Raynaud's phenomenon or acrocyanosis. We report a cas of anorexia nervosa-related vasculopathy associated with iatrogenic injury to the radial artery that led to digital necrosis. An 18-year-old woman, with a history of severe anorexia nervosa of 5 years duration and who acknowledged regular use of tobacco and cannabis, was hospitalized for necrosis of the left index and thumb that had occurred shortly after left radial artery puncture for blood gas analysis. Acrocyanosis of the 4 limbs had been present since the onset of anorexia nervosa. Arteriography of the upper limbs showed major spasm of the left radial and cubital arteries and thromboses in the left interdigital arteries of the left index and thumb. The distal portions of the arteries were then on the left and on the right. The nectrotic lesions healed after intravenous administration of ilomedine and interruption of tobacco and cannabis. Acrocyanosis of the four limbs persisted. We report a case of digital necrosis occurring after arterial puncture for blood gas analysis in a patient with a vascular bed weakened by tobacco and cannabis intoxication but also by anorexia nervosa-related vasculopathy. This observation underlines the potentially dangerous nature of invasive intravascular procedures in this context. Indications for vessel puncture must be assessed with prudence.

  15. Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse

    Directory of Open Access Journals (Sweden)

    Min-Ho Jun

    2016-05-01

    Full Text Available The radial artery pulse is one of the major diagnostic indices used clinically in both Eastern and Western medicine. One of the prominent methods for measuring the radial artery pulse is the piezoresistive sensor array. Independence among channels and an appropriate sensor arrangement are important for effectively assessing the spatial-temporal information of the pulse. This study developed a circular-type seven-channel piezoresistive sensor array using face-down bonding (FDB as one of the sensor combination methods. The three-layered housing structure that included independent pressure sensor units using the FDB method not only enabled elimination of the crosstalk among channels, but also allowed various array patterns to be created for effective pulse measurement. The sensors were arranged in a circular-type arrangement such that they could estimate the direction of the radial artery and precisely measure the pulse wave. The performance of the fabricated sensor array was validated by evaluating the sensor sensitivity per channel, and the possibility of estimating the blood vessel direction was demonstrated through a radial artery pulse simulator. We expect the proposed sensor to allow accurate extraction of the pulse indices for pulse diagnosis.

  16. Vasodilatory effect and endothelial integrity in papaverine- and milrinone-treated human radial arteries.

    Science.gov (United States)

    Rudzinski, P; Wegrzyn, P; Lis, G J; Piatek, J; Konstanty-Kalandyk, J; Nosalski, R; Mikolajczyk, T; Jasinska, M; Pyka-Fosciak, G; Guzik, T; Litwin, J A; Korbut, R; Sadowski, J

    2013-02-01

    Prevention of the vasospasm is an important aspect of coronary artery bypass grafting (CABG) with the use of radial artery (RA) as the conduit. We compared the effect of two phosphodiesterase inhibitors papaverine and milrinone on vasodilation and endothelial integrity of human RA segments harvested from 20 CABG patients. Vasodilatory effect of the drugs were assessed by organ bath technique in RA rings precontracted with KCl and phenylephrine. Endothelial integrity was evaluated by CD34 immunofluorescence in frozen sections. Vasorelaxation induced by papaverine was significantly greater as compared to that induced by milrinone (90.47% ± 10.16% vs. 78.98% ± 19.56%, pmilrinone in the preservation of endothelial integrity (75.3% ± 12.9% vs. 51.8% ± 18.0%, pmilrinone for prevention of vasospasm in radial artery conduits used for CABG.

  17. The effect of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures: a systematic review.

    Science.gov (United States)

    Curtis, Elizabeth; Fernandez, Ritin; Lee, Astin

    2017-07-01

    The uptake of percutaneous coronary procedures via the radial artery has increased internationally due to the decreased risk of complications and increased patient satisfaction. The increased susceptibility of the radial artery to spasm however presents a potential risk for procedural failure. Although most experts agree on the need for prophylactic medications to reduce radial artery spasm, currently there is inconsistency in literature regarding the most effective vasodilatory medication or combination of medications. The objective of this study is to identify the effectiveness of vasodilatory medications on radial artery spasm in patients undergoing transradial coronary artery procedures. This review considered studies that included participants aged 18 years and over undergoing non-emergent transradial percutaneous coronary artery procedures. This review considered studies that used vasodilating intravenous and intra-arterial medications or combinations of medications prior to commencing and during transradial coronary approaches to reduce radial artery spasm. The outcomes of interest were the incidence of radial artery spasm during percutaneous coronary procedure using objective and/or subjective measures and its effect on the successful completion of the procedure. Randomized controlled trials published in the English language between 1989 to date were considered for inclusion. The search strategy aimed to find both published and unpublished studies. A three-step search strategy was utilized in this review. An initial search of MEDLINE, CINAHL and Scopus was undertaken, followed by a search for unpublished studies. Papers selected for retrieval were assessed by two independent reviewers for methodological validity prior to inclusion in the review using standardized critical appraisal instruments. Any disagreements that arose between the reviewers were resolved through discussion. Quantitative data was extracted from papers included in the review using the

  18. A novel compliance measurement in radial arteries using strain-gauge plethysmography

    International Nuclear Information System (INIS)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-01-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C strain ) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29–85 were compared with 14 normotensive patients aged 25–62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005)

  19. A novel compliance measurement in radial arteries using strain-gauge plethysmography.

    Science.gov (United States)

    Liu, Shing-Hong; Tyan, Chu-Chang; Chang, Kang-Ming

    2009-09-01

    We propose a novel method for assessing the compliance of the radial artery by using a two-axis mechanism and a standard positioning procedure for detecting the optimal measuring site. A modified sensor was designed to simultaneously measure the arterial diameter change waveform (ADCW) and pressure pulse waveform with a strain gauge and piezoresistor. In the x-axis scanning, the sensor could be placed close to the middle of the radial artery when the ADCW reached the maximum amplitude. In the Z-axis scanning, the contact pressure was continuously increased for data measurement. Upon the deformation of the strain gauge following the change in the vascular cross-section, the ADCW was transferred to the change of the vascular radius. The loaded strain compliance of the radial artery (C(strain)) can be determined by dividing the dynamic changed radius by the pulse pressure. Twenty-three untreated, mild or moderate hypertensive patients aged 29-85 were compared with 14 normotensive patients aged 25-62. The maximum strain compliance between the two groups was significantly different (p < 0.005). Of the hypertensive patients, 14 were at risk of developing hyperlipidemia. There was a significant difference between this and the normotension group (p < 0.005).

  20. Combined Endovascular Treatment with Distal Radial Artery Coil Embolization and Angioplasty in Steal Syndrome Associated with Forearm Dialysis Fistula

    Energy Technology Data Exchange (ETDEWEB)

    Tercan, Fahri, E-mail: ftercan@yahoo.com; Koçyiğit, Ali, E-mail: alkoc@yahoo.com [Pamukkale University, Department of Radiology, School of Medicine (Turkey); Güney, Bünyamin [Muğla Sıtkı Kocman University, Department of Radiology, School of Medicine (Turkey)

    2016-09-15

    PurposeThe present study was performed to define the results of the endovascular treatment with angioplasty and distal radial artery embolization in ischemic steal syndrome associated with forearm arteriovenous accesses.MethodThe cases referred to our interventional radiology unit with symptoms and physical examination findings suggestive of ischemic steal syndrome were retrospectively evaluated first by Doppler ultrasonography, and then by angiography. Cases with proximal artery stenosis were applied angioplasty, and those with steal syndrome underwent coil embolization to distal radial artery.ResultsOf 589 patients who underwent endovascular intervention for dialysis arteriovenous fistulae (AVF)-associated problems, 6 (1.01 %) (5 female, 1 males; mean age 62 (range 41–78) with forearm fistula underwent combined endovascular treatment for steal syndrome. In addition to steal phenomenon, there were stenosis and/or occlusion in proximal radial and/or ulnar artery in 6 patients concurrently. Embolization of distal radial artery and angioplasty to proximal arterial stenoses were performed in all patients. Ischemic symptoms were eliminated in all patients and the AVF were in use at the time of study. In one patient, ischemic symptoms recurring 6 months later were alleviated by repeat angioplasty of ulnar artery.ConclusionIn palmar arch steal syndrome affecting forearm fistulae, combined distal radial embolization and angioplasty is also an effective treatment method in the presence of proximal radial and ulnar arterial stenoses and occlusions.

  1. Complications and nursing care in interventional treatment of diabetic foot via radial artery access

    International Nuclear Information System (INIS)

    Liu Lingyun; Zhou Xiaoxiang; Zeng Yongmei; Chen Junfei; Lai Lisha; Pang Pengfei; Zhu Kangshun

    2009-01-01

    Objective: To evaluate the therapeutic effect of interventional treatment via radial artery access for diabetic foot and to summarize its complications and nursing care. Methods: The interventional treatment via radial artery access was performed in twenty patients with diabetic foot. The preoperative psychological nursing care, the nursing of the punctured site of radial artery and the indwelling catheter, the complications of the puncture site and thrombolytic therapy were reviewed and retrospectively analyzed. Results: Some complications occurred in eight cases, including hematoma at puncture site (n= 1), oozing of blood (n=3), gingival bleeding (n=1) and pain (n=3). No retention of urine or infection occurred. Conclusion: It is very important to pay enough attention to the nursing care of puncture site and indwelling catheter sheath and to make a close observation of patient's condition in order to reduce the occurrence of complications. Rich clinical experience and careful observation after the operation can definitely reduce the occurrence of thrombolytic complications and improve the patient's living quality. (authors)

  2. Ultrasound evaluation of forearm arteries in patients undergoing percutaneous coronary intervention via radial artery access: results of one-year follow-up.

    Science.gov (United States)

    Peruga, Jan Przemysław; Peruga, Jan Zbigniew; Kasprzak, Jarosław D; Kręcki, Radosław; Jankowski, Łukasz; Zając, Piotr; Plewka, Michał

    2015-01-01

    A proven advantage of radial over femoral arterial access has led to an increase in the number of interventions performed via radial artery access in patients with acute coronary syndromes. Both assessment of the pulse volume and the Allen's test are subjective and subject to investigator bias. An ultrasound examination of the forearm arteries provides important information about the anatomy of the forearm vessels, and indirectly also about the efficiency of collateral blood supply to the hand. It also enables determination of the relevant vessel diameter before the planned intervention, and may be used to assess local complications. To assess the morphology of forearm blood vessels and measure the diameter of both radial and ulnar arteries at the cannulation site using ultrasound imaging. We also aimed to identify potential vascular anomalies and local complications associated with radial artery puncture. The study included 109 patients with cardiologic indications for coronary angiography or coronary angioplasty. An ultrasound evaluation of forearm arteries was performed prior to the intervention, and the vascular anatomy was later verified by angiography during the procedure. Ultrasound measurements of the vessel diameter were also performed and local complications of the cannulation were assessed. Measurements were performed immediately after the procedure and at 30 days and 12 months. Fifty-nine right and 50 left forearm arteries were evaluated. Women were 29% of the study population. The mean patient age was 59.2 ± 7.9 years. The mean diameter of the right radial artery was 2.17 ± 0.54 mm, and the mean diameter of the left radial artery was 2.25 ± 0.43 mm. The measurements revealed gender-related differences in forearm artery diameter (p = 0.003). Vascular anomalies of the radial artery were identified by ultrasound examination in 10% of subjects. A significant dilatation of the cannulated blood vessel was observed which lasted up to 12 months. An

  3. Combined Radial-Pedal Access Strategy and Radial-Pedal Rendezvous in the Revascularization of Complex Total Occlusions of the Superficial Femoral Artery (the "No Femoral Access" Strategy).

    Science.gov (United States)

    Hanna, Elias B; Prout, Davey L

    2016-04-01

    To describe the combined use of radial-pedal access for recanalization of complex superficial femoral artery (SFA) occlusions unsuitable for transfemoral recanalization. Patients are selected for this strategy if they have a long (≥ 10 cm) SFA occlusion with unfavorable aortoiliac anatomy, an absent ostial stump, or severely diseased and calcified distal reconstitution. Left radial artery and distal anterior or posterior tibial artery are accessed with 6-F and 4-F sheaths, respectively. The SFA lesion is crossed retrogradely with a 0.035-inch wire system. If retrograde crossing is not immediately successful, transradial subintimal tracking and radial-pedal subintimal rendezvous are used to allow retrograde reentry. Fifteen patients (mean age 62 ± 5 years; 11 men) have been treated in this fashion, and frequently stented, through the tibiopedal access. Seven patients required radial-pedal rendezvous to facilitate retrograde reentry. Two patients underwent transradial iliac stenting during the same session, and 1 patient underwent transradial kissing angioplasty of the profunda. No major complication occurred in any patient. After the procedure, the pulse across the accessed tibial artery was palpable in all patients. In patients with long and complex SFA occlusion unsuitable for transfemoral recanalization, a radial-pedal strategy can overcome revascularization obstacles. © The Author(s) 2016.

  4. Accurate evaluation of viscoelasticity of radial artery wall during flow-mediated dilation in ultrasound measurement

    Science.gov (United States)

    Sakai, Yasumasa; Taki, Hirofumi; Kanai, Hiroshi

    2016-07-01

    In our previous study, the viscoelasticity of the radial artery wall was estimated to diagnose endothelial dysfunction using a high-frequency (22 MHz) ultrasound device. In the present study, we employed a commercial ultrasound device (7.5 MHz) and estimated the viscoelasticity using arterial pressure and diameter, both of which were measured at the same position. In a phantom experiment, the proposed method successfully estimated the elasticity and viscosity of the phantom with errors of 1.8 and 30.3%, respectively. In an in vivo measurement, the transient change in the viscoelasticity was measured for three healthy subjects during flow-mediated dilation (FMD). The proposed method revealed the softening of the arterial wall originating from the FMD reaction within 100 s after avascularization. These results indicate the high performance of the proposed method in evaluating vascular endothelial function just after avascularization, where the function is difficult to be estimated by a conventional FMD measurement.

  5. Considerations for SphygmoCor radial artery pulse wave analysis: side selection and peripheral arterial blood pressure calibration.

    Science.gov (United States)

    Martin, Jeffrey S; Borges, Alexandra R; Christy, John B; Beck, Darren T

    2015-10-01

    Methods employed for pulse wave analysis (PWA) and peripheral blood pressure (PBP) calibration vary. The purpose of this study was to evaluate the agreement of SphygmoCor PWA parameters derived from radial artery tonometry when considering (1) timing (before vs. after tonometry) and side selection (ipsilateral vs. contralateral limb) for PBP calibration and (2) side selection for tonometry (left vs. right arm). In 34 subjects (aged 21.9 ± 2.3 years), bilateral radial artery tonometry was performed simultaneously on three instances. PBP assessment via oscillometric sphygmomanometry in the left arm only and both arms simultaneously occurred following the first and second instances of tonometry, respectively. Significant within arm differences in PWA parameters derived before and after PBP measurement were observed in the right arm only (for example, aortic systolic blood pressure, Δ=0.38 ± 0.64 mm Hg). Simultaneously captured bilateral PWA variables demonstrated significant between arm differences in 88% (14/16) and 56% (9/16) of outcome variables when calibrated to within arm and equivalent PBP, respectively. Moreover, the right arm consistently demonstrated lower values for clinical PWA variables (for example, augmentation index, bias=-2.79%). However, 26% (n=9) of participants presented with clinically significant differences (>10 mm Hg) in bilateral PBP and their exclusion from analysis abolished most between arm differences observed. SphygmoCor PWA in the right radial artery results in greater variability independent of the timing of PBP measurement and magnitude of calibration pressures in young subjects. Moreover, bilateral PBP measurement is imperative to identify subjects in whom a significant difference in bilateral PWA outcomes may exist.

  6. Transluminal recanalization of chronic total occlusion of radial artery using rendezvous technique: a case report and literature review.

    Science.gov (United States)

    Arabi, Mohammad; Ahmed, Ishtiaq; Qattan, Nabeel

    2014-01-01

    Although endovascular management of lower extremity peripheral arterial disease (PAD) is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO) using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  7. Transluminal Recanalization of Chronic Total Occlusion of Radial Artery Using Rendezvous Technique: A Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Mohammad Arabi

    2014-01-01

    Full Text Available Although endovascular management of lower extremity peripheral arterial disease (PAD is well studied, little information exists regarding endovascular treatment of critical upper limb ischemia. We report a case of transluminal recanalization of right radial artery chronic total occlusion (CTO using rendezvous technique in a patient with critical hand ischemia and dry gangrene of the right index finger.

  8. radial

    Directory of Open Access Journals (Sweden)

    JOHN WILLIAM BRANCH

    2007-01-01

    Full Text Available La creación de modelos de objetos reales es una tarea compleja para la cual se ha visto que el uso de técnicas tradicionales de modelamiento tiene restricciones. Para resolver algunos de estos problemas, los sensores de rango basados en láser se usan con frecuencia para muestrear la superficie de un objeto desde varios puntos de vista, lo que resulta en un conjunto de imágenes de rango que son registradas e integradas en un modelo final triangulado. En la práctica, debido a las propiedades reflectivas de la superficie, las oclusiones, y limitaciones de acceso, ciertas áreas de la superficie del objeto usualmente no son muestreadas, dejando huecos que pueden crear efectos indeseables en el modelo integrado. En este trabajo, presentamos un nuevo algoritmo para el llenado de huecos a partir de modelos triangulados. El algoritmo comienza localizando la frontera de las regiones donde están los huecos. Un hueco consiste de un camino cerrado de bordes de los triángulos en la frontera que tienen al menos un borde que no es compartido con ningún otro triangulo. El borde del hueco es entonces adaptado mediante un B-Spline donde la variación promedio de la torsión del la aproximación del B-spline es calculada. Utilizando un simple umbral de la variación promedio a lo largo del borde, se puede clasificar automáticamente, entre huecos reales o generados por intervención humana. Siguiendo este proceso de clasificación, se usa entonces una versión automatizada del interpolador de funciones de base radial para llenar el interior del hueco usando los bordes vecinos.

  9. Ulnar Artery Compression: A Feasible and Effective Approach to Prevent the Radial Artery Occlusion after Coronary Intervention

    Directory of Open Access Journals (Sweden)

    Jun Tian

    2015-01-01

    Full Text Available Background: Radial artery (RA occlusion (RAO is not rare in patients undergoing coronary intervention by transradial approach (TRCI. Predictors of and prevention from RAO have not been systematically studied. This study aimed to analyze the risk factors of the weakness of RA pulsation (RAP and its predictive value for RAO after TRCI, and simultaneously to describe a feasible and effective approach to maintain RA patency. Methods: Between June 2006 and March 2010, all patients who underwent TRCI were classified according to the weakness of RAP after removing compression bandage with confirmation by Doppler ultrasound for the first 30 consecutive patients. Among a total of 2658 patients studied, 187 (7% patients having a weaker RAP were prospectively monitored. At 1 h after bandage removal, the ulnar artery in puncture side of all patients was blocked with manual compression to favor brachial and collateral artery blood flow through the RA until a good RAP was restored. The primary analysis was the occurrence of RAO. Results: Doppler ultrasound demonstrated the significant reduction of both systolic velocity (61.24 ± 3.95 cm/s vs. 72.31 ± 3.57 cm/s and diastolic velocity (1.83 ± 0.32 cm/s vs. 17.77 ± 3.97 cm/s in RA at access side as compared to the contralateral RA (all P < 0.001, but these velocities in ipsilateral ulnar artery (81.2 ± 2.16 cm/s and 13.1 ± 2.86 cm/s, respectively increased profoundly. The average time of ulnar artery compression was 4.1 ± 1.2 h (ranged 2.5-6.5 h. There were two patients experienced persistent RAO with a success rate of 98.9% and RAO in 0.075% of patients after ulnar artery compression was applied. The pulsation of the ulnar artery after compression was removed had not been influenced by the compression. Conclusions: After intervention using TRCI approach, the presence of a weaker RAP is an indicator of imminent RAO. The continuing compression of ipsilateral ulnar artery is an effective approach to

  10. Determination of the luminal diameter of the radial artery in man by high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1990-01-01

    measurements. By comparing the diameter of the reference object either filled with water or blood at 37 degrees C, the ultrasound velocity in human blood at 37 degrees C was calculated to be 1605 m/s. The intraobserver repeatability coefficients of in-vivo measurements of the radial artery in man were...... in the same range, whether measurements were repeated after 30 min (14%) or from day to day (12%). The interobserver repeatability coefficient was acceptable (15%) when the site of measurements was marked, whereas measurements without a mark resulted in a repeatability coefficient of 24%. The intravenous...

  11. Comparison of femoropopliteal artery stents under axial and radial compression, axial tension, bending, and torsion deformations.

    Science.gov (United States)

    Maleckis, Kaspars; Deegan, Paul; Poulson, William; Sievers, Cole; Desyatova, Anastasia; MacTaggart, Jason; Kamenskiy, Alexey

    2017-11-01

    High failure rates of Peripheral Arterial Disease (PAD) stenting appear to be associated with the inability of certain stent designs to accommodate severe biomechanical environment of the femoropopliteal artery (FPA) that bends, twists, and axially compresses during limb flexion. Twelve Nitinol stents (Absolute Pro, Supera, Lifestent, Innova, Zilver, Smart Control, Smart Flex, EverFlex, Viabahn, Tigris, Misago, and Complete SE) were quasi-statically tested under bench-top axial and radial compression, axial tension, bending, and torsional deformations. Stents were compared in terms of force-strain behavior, stiffness, and geometrical shape under each deformation mode. Tigris was the least stiff stent under axial compression (6.6N/m axial stiffness) and bending (0.1N/m) deformations, while Smart Control was the stiffest (575.3N/m and 105.4N/m, respectively). Under radial compression Complete SE was the stiffest (892.8N/m), while Smart Control had the lowest radial stiffness (211.0N/m). Viabahn and Supera had the lowest and highest torsional stiffness (2.2μNm/° and 959.2μNm/°), respectively. None of the 12 PAD stents demonstrated superior characteristics under all deformation modes and many experienced global buckling and diameter pinching. Though it is yet to be determined which of these deformation modes might have greater clinical impact, results of the current analysis may help guide development of new stents with improved mechanical characteristics. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Effects of various factors on Doppler ultrasonographic measurements of radial and coccygeal arterial blood pressure in privately owned, conscious cats.

    Science.gov (United States)

    Whittemore, Jacqueline C; Nystrom, Michael R; Mawby, Dianne I

    2017-04-01

    OBJECTIVE To assess the effects of age, body condition score (BCS), and muscle condition score (MCS) on radial and coccygeal systolic arterial blood pressure (SAP) in cats. DESIGN Prospective randomized trial. ANIMALS 66 privately owned cats enrolled between May and December 2010. PROCEDURES BCS and MCS of cats were assessed by 2 investigators; SAP was measured via Doppler ultrasonic flow detector, with cats positioned in right lateral or sternal recumbency for measurements at the radial or coccygeal artery, respectively, with order of site randomized. Associations among variables were assessed through correlation coefficients, partial correlation coefficients, and ANCOVA. RESULTS Interrater reliability for BCS and MCS assessment was high (correlation coefficients, 0.95 and 0.83, respectively). No significant effect was identified for order of SAP measurement sites. Coccygeal and radial SAP were positively correlated (ρ = 0.45). The median difference in coccygeal versus radial SAP was 19 mm Hg, but differences were not consistently positive or negative. Radial SAP was positively correlated with age (ρ = 0.48) and negatively correlated with MCS (ρ = -0.30). On the basis of the correlation analysis, the association between radial SAP and MCS reflected the confounding influence of age. Coccygeal SAP was not significantly correlated with age, BCS, or MCS. CONCLUSIONS AND CLINICAL RELEVANCE Use of the coccygeal artery is recommended to reduce the confounding effects of age and sarcopenia on Doppler ultrasonographic SAP measurements in cats. Additionally, monitoring for changes in MCS is recommended for cats undergoing serial SAP measurement.

  13. Endothelial dysfunction and the occurrence of radial artery spasm during transradial coronary procedures: The ACRA-Spasm study

    NARCIS (Netherlands)

    Van Der Heijden, D.J. (Dirk J.); M.A.H. van Leeuwen (Maarten); G.N. Janssens (Gladys N.); Hermie, J. (Jailen); M.J. Lenzen (Mattie); M.J.P.F. Ritt; P.M. van de Ven (Peter); F. Kiemeneij (Ferdinand); N. van Royen (Niels)

    2016-01-01

    textabstractAims: The aim of this study was to analyse the relation between endothelial dysfunction (ED) and the occurrence of radial artery spasm (RAS) during transradial coronary procedures. Methods and results: From May 2014 to June 2015, endothelial function was assessed by EndoPAT and FMD

  14. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    Full Text Available Abstract Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min.

  15. Lack of tolerance of headache and radial artery diameter during a 7 hour intravenous infusion of nitroglycerin

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Tfelt-Hansen, P

    1993-01-01

    . The intensity of the headache was mild to medium (median headache score 3, range 1-7). The mean dilatation of the radial artery was 36%. The dilatation in each individual, was stable over time, both during NTG and placebo, and it did not change with the double infusion rate. The headache score in each......Nitroglycerin-(NTG)-induced headache and dilatation of the radial artery were followed in a double blind, randomized, placebo-controlled, cross-over study in 6 healthy volunteers. NTG 0.5 microgram.kg-1 x min-1 or saline were infused i.v. for 7 h, and subsequently the infusion rate was doubled...... individual was more fluctuant. No tolerance either to the NTG-induced headache or arterial dilatation was observed....

  16. Radial artery pulse waveform analysis based on curve fitting using discrete Fourier series.

    Science.gov (United States)

    Jiang, Zhixing; Zhang, David; Lu, Guangming

    2018-04-19

    Radial artery pulse diagnosis has been playing an important role in traditional Chinese medicine (TCM). For its non-invasion and convenience, the pulse diagnosis has great significance in diseases analysis of modern medicine. The practitioners sense the pulse waveforms in patients' wrist to make diagnoses based on their non-objective personal experience. With the researches of pulse acquisition platforms and computerized analysis methods, the objective study on pulse diagnosis can help the TCM to keep up with the development of modern medicine. In this paper, we propose a new method to extract feature from pulse waveform based on discrete Fourier series (DFS). It regards the waveform as one kind of signal that consists of a series of sub-components represented by sine and cosine (SC) signals with different frequencies and amplitudes. After the pulse signals are collected and preprocessed, we fit the average waveform for each sample using discrete Fourier series by least squares. The feature vector is comprised by the coefficients of discrete Fourier series function. Compared with the fitting method using Gaussian mixture function, the fitting errors of proposed method are smaller, which indicate that our method can represent the original signal better. The classification performance of proposed feature is superior to the other features extracted from waveform, liking auto-regression model and Gaussian mixture model. The coefficients of optimized DFS function, who is used to fit the arterial pressure waveforms, can obtain better performance in modeling the waveforms and holds more potential information for distinguishing different psychological states. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Treatment of giant and large fusiform middle cerebral artery aneurysms with excision and interposition radial artery graft in a 4-year-old child: case report.

    Science.gov (United States)

    Mrak, Goran; Paladino, Josip; Stambolija, Vasilije; Nemir, Jakob; Sekhar, Laligam N

    2014-03-01

    We report an unusual case of complex giant and large fusiform aneurysms not amenable for clipping or coiling in a 4-year-old child managed with aneurysm resection and radial artery interposition graft. A 4-year-old child presented with repeated severe headache and vomiting. Computed tomography, magnetic resonance imaging, and magnetic resonance angiography and digital subtraction angiography showed a giant fusiform aneurysm on the right middle cerebral artery (MCA). Because of the complex shape, endovascular treatment or clip reconstruction was not possible, and a bypass procedure was planned. Right frontotemporal craniotomy and orbitotomy was performed. Two aneurysms involving the M1 segment of the MCA were found in line, 1 giant, and the other large in size. The aneurysms were resected and treated with short radial artery interposition graft, which was narrower than the proximal or distal MCA. The child recovered normally, and the bypass was patent after 1 year. Large fusiform MCA aneurysms may be difficult to treat, but there are treatment options that include a bypass procedure. Resection and short interposition radial artery graft is an excellent but rare treatment option in a very young child. This was a very successful treatment in this child.

  18. Investigation of occupational radiation exposure during interventional cardiac catheterizations performed via radial artery

    International Nuclear Information System (INIS)

    Goni, H.; Papadopoulou, D.; Yakoumakis, Em; Stratigis, N.; Benos, J.; Siriopoulou, V.; Makri, Tr; Georgiou, Ev

    2005-01-01

    The purpose of this study was to determine the thyroid, sternum and hand radiation doses of radiologists who perform angiographies and angio-plasties via the radial artery. Staff radiation dose was estimated for 21 cardiac interventional catheterizations. Thermoluminescence dosemeters (TLDs) were used to determine radiation dose for each procedure at the right and left wrist, at the sternum and the thyroid. A dose area product (DAP) meter was also attached to give a direct value in Gy cm 2 for each procedure. Staff radiation doses varied between 34 and 235 μGy per procedure at the left wrist, 28 and 172 μGy at the right wrist, 16 and 106 μGy at the level of the thyroid and 16 and 154 μGy at the level of the sternum. The DAP values varied between 25 and 167 Gy cm 2 . Radiation doses in this study are comparable to those reported in previous studies. Moreover, good correlation was found between the DAP values and the occupational dose measured with TLDs. (authors)

  19. Relationship between preoperative radial artery and postoperative arteriovenous fistula blood flow in hemodialysis patients.

    Science.gov (United States)

    Sato, Michiko; Io, Hiroaki; Tanimoto, Mitsuo; Shimizu, Yoshio; Fukui, Mitsumine; Hamada, Chieko; Horikoshi, Satoshi; Tomino, Yasuhiko

    2012-01-01

    It is recommended that arteriovenous fistula (AVF) blood flow should be more than 425 ml/min before cannulation. However, the relationship between preoperative radial artery flow (RAF) and postoperative AVF blood flow has still not been examined. Sixty-one patients with end-stage kidney disease (ESKD) were examined. They had an AVF prepared at Juntendo University Hospital from July 2006 through August 2007. Preoperative RAF and postoperative AVF blood flows were measured by ultrasonography. AVF blood flow gradually increased after the operation. AVF blood flow was significantly correlated with preoperative RAF. When preoperative RAF exceeded 21.4 ml/min, AVF blood flow rose to more than 425 ml/min. The postoperative AVF blood flow in the group with RAF of more than 20 ml/min was significantly higher than that in those with less than 20 ml/min. Preoperative RAF of less than 20 ml/min had a significantly high risk of primary AVF failure within 8 months compared with that of more than 20 ml/min. It appears that measurement of RAF by ultrasonography is useful for estimating AVF blood flow postoperatively and can predict the risk of complications in ESKD patients.

  20. Evaluación de hipertensos en base a registros de variación de diámetro arterial radial Evaluation of hypertensive patients by radial arterial diameter variation recording

    Directory of Open Access Journals (Sweden)

    Fernando M. Clara

    2006-12-01

    Full Text Available Se utilizó la técnica de análisis del registro incruento de las variaciones de diámetro de arteria radial para evaluar el deterioro arterial y el riesgo cardiovascular en pacientes hipertensos. El transductor utilizado consistió en un sensor de movimiento apoyado sobre la zona de palpación del pulso radial. Se efectuó la determinación del índice de aumentación radial, un parámetro que cuantifica la magnitud de las reflexiones de la onda de presión en la región aórtica, sobre un conjunto de 47 hipertensos, y se lo comparó con otro estudio similar efectuado sobre 81 normotensos sanos. Estos últimos presentaron menores valores de dicho índice, pero al avanzar la edad los valores de ambos grupos tendieron a coincidir. Esto fue confirmado al comparar morfológicamente los registros de ambos grupos, hallándose que los registros de ancianos normotensos sanos e hipertensos de edades similares resultaron visiblemente parecidos. Se halló también que determinados hipertensos jóvenes presentaron ciertas características morfológicas similares a las de normotensos de la misma edad, indicando que aún conservaban las características elásticas propias de su grupo etario. Los resultados fueron similares a los logrados sobre registros de presión arterial radial obtenidos mediante tonometría de aplanación, utilizándose una tecnología disponible en nuestro medio y de menor costo.A blood less analysis technique of the diameter variation signal at radial artery was used to evaluate the arterial disease and the cardiovascular risk in hypertensive patients. A movement transducer was used to record the wrist pulse. A radial augmentation index was proposed to quantify the magnitude of the pressure wave reflections in the aortic region. The experiment was carried out with a group of 47 hypertensive men and compared with a similar study performed on 81 normotensive healthy men. The last ones presented smaller values of this index, but as age

  1. Differences in perioperative femoral and radial arterial blood pressure in neonates and infants undergoing cardiac surgery requiring cardiopulmonary bypass

    Directory of Open Access Journals (Sweden)

    Hwa Jin Cho

    2018-01-01

    Full Text Available Objective: Several reports claim that blood pressure (BP in the radial artery may underestimate the accurate BP in critically ill patients. Here, the authors evaluated differences in mean blood pressure (MBP between the radial and femoral artery during pediatric cardiac surgery to determine the effectiveness of femoral arterial BP monitoring. Method: The medical records of children under 1 year of age who underwent open-heart surgery between 2007 and 2013 were retrospectively reviewed. Radial and femoral BP were measured simultaneously, and the differences between these values were analyzed at various times: after catheter insertion, after the initiation of cardiopulmonary bypass (CPB-on, after aortic cross clamping (ACC, after the release of ACC, after weaning from CPB, at arrival in the intensive care unit (ICU, and every 6 h during the first day in the ICU. Results: A total of 121 patients who underwent open-heart surgery met the inclusion criteria. During the intraoperative period, from the beginning to the end of CPB, radial MBPs were significantly lower than femoral MBPs at each time-point measured (p 60 min, odds ratio: 7.47 was a risk factor for lower radial pressure. However, discrepancies between these two values disappeared after arrival in the ICU. There was no incidence of ischemic complications associated with the catheterization of both arteries. Conclusion: The authors suggest that femoral arterial pressure monitoring can be safely performed, even in neonates, and provides more accurate BP values during CPB-on periods, and immediately after weaning from CPB, especially when CPB time was greater than 60 min. Resumo: Objetivo: Diversos relatos alegam que a pressão arterial (PA na artéria radial poderá subestimar a PA precisa em pacientes gravemente doentes. Aqui, avaliamos diferenças na pressão arterial média (PAM entre a artéria radial e femoral durante cirurgia cardíaca pediátrica para determinar a eficácia do

  2. 2-Octyl Cyanoacrylate (Dermabond® skin adhesive versus polyglactin for skin closure in endoscopic radial artery harvesting

    Directory of Open Access Journals (Sweden)

    Ahmed Mostafa Omran

    2018-03-01

    Full Text Available Background: As the goal of endoscopic conduit harvesting is to decrease pain and better cosmetic appearance, and as the optimal choice of skin closure after endoscopic radial artery harvesting (ERAH has not yet been determined, we started this study with an aim to compare wound complications, patient satisfaction and scar healing between glue (Dermabond versus polyglactin intra-cuticular suture for skin closure after ERAH. Methods: This observational study was done at Al Dabbous Cardiac Center, Kuwait, from January 2017 till October 2017 enrolling 40 patients divided into two equal groups (Dermabond group and sutures group. Inclusion criterion was patients underwent coronary artery bypass grafting (CABG using ERAH, while open technique for radial artery harvesting and Negro race are considered as exclusion criteria. Demographic data were collected, (gender, age, race, body mass index (BMI, preoperative medication and albumin level, as well as diabetes or peripheral vascular disease. Operatively, wound closure time was calculated for all patients. Postoperatively: Cosmetic appearance was assessed using the Hollander scale. Patient satisfaction was recorded at week 6–8 weeks. Results: Demographic and preoperative data were comparable; Dermabond group showed shorter closure time, better scar pigmentation, shape and patient satisfaction. Pain, scar size, infection and hematoma showed no statistical difference. Conclusion: Dermabond can be used safely in closure of skin after ERAH. The excellent results in the small wound of ERAH encouraged us to use it in larger wounds. Keywords: Dermabond, Wound, ERAH, Skin adhesive, OCA

  3. Radial artery anomalies in patients undergoing transradial coronary procedures – An Egyptian multicenter experience

    Directory of Open Access Journals (Sweden)

    Ayman K.M. Hassan

    2016-03-01

    Conclusion: There is a relatively significant presence of radial anomalies, with different degrees of impact on procedural failure rate, in our Egyptian population. Further collaborative studies are recommended to increase our success rates.

  4. Comparison of the feasibility and effectiveness of transradial coronary angiography via right versus left radial artery approaches (from the PREVAIL Study).

    Science.gov (United States)

    Pelliccia, Francesco; Trani, Carlo; Biondi-Zoccai, Giuseppe G L; Nazzaro, Marco; Berni, Andrea; Patti, Giuseppe; Patrizi, Roberto; Pironi, Bruno; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio; Pristipino, Christian

    2012-09-15

    It remains undefined if transradial coronary angiography from a right or left radial arterial approach differs in real-world practice. To address this issue, we performed a subanalysis of the PREVAIL study. The PREVAIL study was a prospective, multicenter, observational survey of unselected consecutive patients undergoing invasive cardiovascular procedures over a 1-month observation period, specifically aimed at assessing the outcomes of radial approach in the contemporary real world. The choice of arterial approach was left to the discretion of the operator. Prespecified end points of this subanalysis were procedural characteristics. Of 1,052 patients consecutively enrolled, 509 patients underwent transradial catheterization, 304 with a right radial and 205 with a left radial approach. Procedural success rates were similar between the 2 groups. Compared to the left radial group, the right radial group had longer procedure duration (46 ± 29 vs 33 ± 24 minutes, p <0.0001) and fluoroscopy time (765 ± 787 vs 533 ± 502, p <0.0001). At multivariate analysis, including a parsimonious propensity score for the choice of left radial approach, duration of procedure (beta coefficient 11.38, p <0.001) and total dose-area product (beta coefficient 11.38, p <0.001) were independently associated with the choice of the left radial artery approach. The operator's proficiency in right/left radial approach did not influence study results. In conclusion, right and left radial approaches are feasible and effective to perform percutaneous procedures. In the contemporary real world, however, the left radial route is associated with shorter procedures and lower radiologic exposure than the right radial approach, independently of an operator's proficiency. Copyright © 2012 Elsevier Inc. All rights reserved.

  5. Comparison between ultrasound guided technique and digital palpation technique for radial artery cannulation in adult patients: An updated meta-analysis of randomized controlled trials.

    Science.gov (United States)

    Bhattacharjee, Sulagna; Maitra, Souvik; Baidya, Dalim K

    2018-03-22

    Possible advantages and risks associated with ultrasound guided radial artery cannulation in-comparison to digital palpation guided method in adult patients are not fully known. We have compared ultrasound guided radial artery cannulation with digital palpation technique in this meta-analysis. Meta-analysis of randomized controlled trials. Trials conducted in operating room, emergency department, cardiac catheterization laboratory. PubMed and Cochrane Central Register of Controlled Trials (CENTRAL) were searched (from 1946 to 20th November 2017) to identify prospective randomized controlled trials in adult patients. Two-dimensional ultrasound guided radial artery catheterization versus digital palpation guided radial artery cannulation. Overall cannulation success rate, first attempt success rate, time to cannulation and mean number of attempts to successful cannulation. Odds ratio (OR) and standardized mean difference (SMD) or mean difference (MD) with 95% confidence interval (CI) were calculated for categorical and continuous variables respectively. Data of 1895 patients from 10 studies have been included in this meta- analysis. Overall cannulation success rate was similar between ultrasound guided technique and digital palpation [OR (95% CI) 2.01 (1.00, 4.06); p = 0.05]. Ultrasound guided radial artery cannulation is associated with higher first attempt success rate of radial artery cannulation in comparison to digital palpation [OR (95% CI) 2.76 (186, 4.10); p guided technique with palpation technique. Radial artery cannulation by ultrasound guidance may increase the first attempt success rate but not the overall cannulation success when compared to digital palpation technique. However, results of this meta-analysis should be interpreted with caution due presence of heterogeneity. Copyright © 2018. Published by Elsevier Inc.

  6. Effects of arm elevation on radial artery pressure: a new method to distinguish hypovolemic shock and septic shock from hypotension.

    Science.gov (United States)

    Xie, Zhiyi; Zhang, Zhenyu; Xu, Yuan; Zhou, Hua; Wu, Sheng; Wang, Zhong

    2018-06-01

    In this prospective observational study, we investigated the variability in radial artery invasive blood pressure associated with arm elevation in patients with different hemodynamic types. We carried out a prospective observational study using data from 73 general anesthesia hepatobiliary postoperative adult patients admitted to an ICU over a 1-year period. A standard procedure was used for the arm elevation test. The value of invasive radial arterial pressure was recorded at baseline, and 30 and 60 s after the arm had been raised from 0° to 90°. We compared the blood pressure before versus after arm elevation, and between hemodynamically stable, hypovolemic shock, and septic shock patient groups. In all 73 patients, systolic arterial pressure (SAP) decreased, diastolic arterial pressure (DAP) increased, and pulse pressure (PP) decreased at 30 and 60 s after arm elevation (Ppressure (MAP) was unchanged (P>0.05). On comparing 30 and 60 s, there was no significant difference in SAP, DAP, PP, or MAP (P>0.05). In 40 hemodynamically stable patients, SAP and PP decreased, and DAP and MAP increased significantly at 30 and 60 s after arm elevation compared with baseline (P0.05). In 17 patients with septic shock, SAP, PP, and MAP decreased significantly versus baseline at 30 and 60 s (P0.05). Comparison of the absolute value of pressure change of septic shock patients at 30 s after raising the arm showed that SAP, DAP, and MAP changes were significantly lower compared with those in hypovolemic shock and hemodynamically stable patients (Parm elevation of SAP. The best cut-off point for the SAP change value was -5 mmHg or less, with a sensitivity of 94.12%, a specificity of 80.36%, a positive likelihood ratio of 4.79 (95% CI: 2.8-8.2), and a negative likelihood ratio of 0.073 (95% CI: 0.01-0.5). Our study shows that hypovolemic shock and septic shock patients have significantly different radial artery invasive blood pressure changes in an arm elevation test

  7. Pulmonary artery imaging under free-breathing using golden-angle radial bSSFP MRI: a proof of concept.

    Science.gov (United States)

    Fyrdahl, Alexander; Vargas Paris, Roberto; Nyrén, Sven; Holst, Karen; Ugander, Martin; Lindholm, Peter; Sigfridsson, Andreas

    2018-03-14

    To evaluate the feasibility of an improved motion and flow robust methodology for imaging the pulmonary vasculature using non-contrast-enhanced, free-breathing, golden-angle radial MRI. Healthy volunteers (n = 10, age 46 ± 11 years, 50% female) and patients (n = 2, ages 27 and 84, both female) were imaged at 1.5 T using a Cartesian and golden-angle radial 2D balanced SSFP pulse sequence. The acquisitions were made under free breathing without contrast agent enhancement. The radial acquisitions were reconstructed at 3 temporal footprints. All series were scored from 1 to 5 for perceived diagnostic quality, artifact level, and vessel sharpness in multiple anatomical locations. In addition, vessel sharpness and blood-to-blood clot contrast were measured. Quantitative measurements showed higher vessel sharpness for golden-angle radial (n = 76, 0.79 ± 0.11 versus 0.71 ± 0.16, p golden-angle radial in the 2 patients. At comparable temporal footprints, golden-angle radial was scored higher for diagnostic quality (mean ± SD, 2.3 ± 0.7 versus 2.2 ± 0.6, p < .01) and vessel sharpness (2.2 ± 0.8 versus 2.1 ± 0.5, p < .01), whereas the artifact level did not differ (3.0 ± 0.9 versus 3.0 ± 1.0, p = .80). The ability to retrospectively choose a temporal resolution and perform sliding-window reconstructions was demonstrated in patients. In pulmonary artery imaging, the motion and flow robustness of a radial trajectory does both improve image quality over Cartesian trajectory in healthy volunteers, and allows for flexible selection of temporal footprints and the ability to perform real-time sliding window reconstructions, which could potentially provide further diagnostic insight. © 2018 International Society for Magnetic Resonance in Medicine.

  8. Human urotensin II in internal mammary and radial arteries of patients undergoing coronary surgery

    DEFF Research Database (Denmark)

    Chen, Zhi-Wu; Yang, Qin; Huang, Yu

    2009-01-01

    (max):20.4+/-4.8%, p7.1%). The relaxation was abolished by endothelium denudation...... and by indomethacin, oxadiazoloquinoxalinone or N(omega)-nitro-L-arginine, oxyhemoglobin, and Ca2+-activated K+ channel (K(Ca)) blockers. Urotensin receptor mRNA was detected in both arteries. CONCLUSIONS: hU-II is an important spasmogen in arterial grafts with receptors expressed in IMA and RA. hU-II elicits...

  9. Similar Outcomes in Diabetes Patients After Coronary Artery Bypass Grafting With Single Internal Thoracic Artery Plus Radial Artery Grafting and Bilateral Internal Thoracic Artery Grafting.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Koprivanac, Marijan; Ravichandren, Kirthi; Javadikasgari, Hoda; Bakaeen, Faisal G; Svensson, Lars G; Sabik, Joseph F

    2017-12-01

    The purpose of this study was to determine in patients with diabetes mellitus whether single internal thoracic artery (SITA) plus radial artery (RA) grafting yields outcomes similar to those of bilateral internal thoracic artery (BITA) grafting. From January 1994 to January 2011, 1,325 diabetic patients underwent primary isolated coronary artery bypass graft surgery with either (1) SITA plus RA with or without saphenous vein (SV) grafts (n = 965) or (2) BITA with or without SV grafts (n = 360); an internal thoracic artery was used in all patients to graft the left anterior descending coronary artery. Endpoints were in-hospital outcomes and time-related mortality. Median follow-up was 7.4 years, with a total follow-up of 9,162 patient-years. Propensity score matching was performed to identify 282 well-matched pairs for adjusted comparisons. Unadjusted in-hospital mortality was 0.52% for SITA plus RA with or without SV grafts and 0.28% for BITA with or without SV grafts, and prevalence of deep sternal wound infection was 3.2% and 1.7%, respectively. Unadjusted survival at 1, 5, 10, and 14 years was 97%, 88%, 68%, and 51% for SITA plus RA with or without SV grafts, and 97%, 95%, 80%, and 66% for BITA with or without SV grafts, respectively. Among propensity-matched patients, in-hospital mortality (0.35% versus 0.35%) and prevalence of deep sternal wound infection (1.4% versus 1.4%) were similar (p > 0.9) in the two groups, as was 1-, 5-, 10-, and 14-year survival: 97%, 90%, 70%, and 58% for SITA plus RA with or without SV grafting versus 97%, 93%, 79%, and 64% for BITA with or without SV grafting, respectively (early p = 0.8, late p = 0.2). For diabetic patients, SITA plus RA with or without SV grafting and BITA with or without SV grafting yield similar in-hospital outcomes and long-term survival after coronary artery bypass graft surgery. Therefore, both SITA plus RA and BITA plus SV grafting should be considered for these patients. Copyright © 2017 The Society

  10. Comparison of a priori versus provisional heparin therapy on radial artery occlusion after transradial coronary angiography and patent hemostasis (from the PHARAOH Study).

    Science.gov (United States)

    Pancholy, Samir B; Bertrand, Olivier F; Patel, Tejas

    2012-07-15

    Systemic anticoagulation decreases the risk of radial artery occlusion (RAO) after transradial catheterization and standard occlusive hemostasis. We compared the efficacy and safety of provisional heparin use only when the technique of patent hemostasis was not achievable to standard a priori heparin administration after radial sheath introduction. Patients referred for coronary angiography were randomized in 2 groups. In the a priori group, 200 patients received intravenous heparin (50 IU/kg) immediately after sheath insertion. In the provisional group, 200 patients did not receive heparin during the procedure. After sheath removal, hemostasis was obtained using a TR band (Terumo corporation, Tokyo, Japan) with a plethysmography-guided patent hemostasis technique. In the provisional group, no heparin was given if radial artery patency could be obtained and maintained. If radial patency was not achieved, a bolus of heparin (50 IU/kg) was given. Radial artery patency was evaluated at 24 hours (early RAO) and 30 days after the procedure (late RAO) by plethysmography. Patent hemostasis was obtained in 67% in the a priori group and 74% in the provisional group (p = 0.10). Incidence of RAO remained similar in the 2 groups at the early (7.5% vs 7.0%, p = 0.84) and late (4.5% vs 5.0%, p = 0.83) evaluations. Women, patients with diabetes, patients having not received heparin, and patients without radial artery patency during hemostasis had more RAO. By multivariate analysis, patent radial artery during hemostasis (odds ratio [OR] 0.03, 95% confidence interval [CI] 0.004 to 0.28, p = 0.002) and diabetes (OR 11, 95% CI 3 to 38,p patent hemostasis is maintained. Copyright © 2012 Elsevier Inc. All rights reserved.

  11. Effects of gravity-induced upper-limb blood pressure changes on wave transmission and arterial radial waveform.

    Science.gov (United States)

    Pucci, Giacomo; Battista, Francesca; Anastasio, Fabio; Sanesi, Leandro; Gavish, Benjamin; Butlin, Mark; Avolio, Alberto; Schillaci, Giuseppe

    2016-06-01

    Local blood pressure (BP) changes induced by arm tilting may influence pressure wave transmission and reflection. We investigated the effects of upper-limb tilting on radial augmentation index (rAIx) and related central measures [aortic augmentation index (aAIx)]. In 45 volunteers (age 49 ± 19 years), supine brachial BP and radial artery waveforms were obtained by applanation tonometry with the dominant arm stretched and gently supported in three different positions: at the heart level, with the BP cuff 15 cm above heart level (approximately +30°), and 15 cm below heart level (-30°). Brachial SBP/DBP was 120/68 ± 17/8 mmHg. Mean arterial pressure changed predictably with arm tilting (99 ± 12 mmHg at -30°, 88 ± 10 mmHg at 0°, 77 ± 11 mmHg at +30°, all P < 0.001). rAIx decreased at -30° (69 ± 22%), and increased at +30° (93 ± 20%) compared with 0° (82 ± 20%, all P less than 0.001). Changes in rAIx (value at +30° minus value at -30°) showed an inverse relationship with age (r = -0.32, P = 0.03). Heart rate, BP and rAIx did not change in the contralateral arm, which was held at the heart level during the examination. aAIx followed the same pattern as rAIx (123 ± 27% at -30°, 144 ± 33% at +30°, 136 ± 31% at 0°, all P less than 0.001); changes in rAIx and aAIx were strongly related each other (r = 0.82, P < 0.001). Acute gravitational upper-limb BP changes generate opposite, profound changes in rAIx, and major artifactual changes in aAIx. These findings provide a rationale for recommending to keep the upper limb at the heart level during radial waveform assessment.

  12. A comparison of direct technique with the liquid stylet technique of radial artery cannulation in patients presenting for coronary artery bypass grafting

    International Nuclear Information System (INIS)

    Younus, U.; Ahmed, I.

    2012-01-01

    To compare direct technique with the liquid stylet technique of radial artery cannulation in patients undergoing coronary artery byroms grouping. We hypothesized that liquid stylet technique would lead to fewer attempts and save vital time. Study Design: Randomized controlled Trial (RCT). Place and Duration of Study: Department of Anaesthesia and Intensive Care, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, [AFIC-NIHD] Rawalpindi, between 1 July 2007 to 31 Dec 2007. Patients and Methods: One hundred patients of either sex scheduled for CABG were included and were randomized to 2 groups using random number table. Fifty patients in the direct technique group and 50 in the liquid stylet group. Results: These two groups comparable with respect to age, gender and weight were studied. The number of attempts in group 1 were 1.7+-0.5 vs 3.6+-1.6 in groups 2, (p=0.021). The time consumed in group was 3.3 +- 2.2 minutes while in groups 2 it was 8.0 +- 3.6 (p=0.022). Conclusion: We concluded that the liquid stylet technique is safe, quick and is associated with lesser number of attempts at cannulation. Secondly it can be done without fancy guide wires and other technology especially in a developing country like Pakistan. (author)

  13. Pulsatility Index of Blood Echogenicity of the Human Radial and Common Carotid Arteries: Relation with Age and Stroke

    International Nuclear Information System (INIS)

    Bok, Tae Hoon; Kong, Qi; Nam, Kweon Ho; Choi, Jay Chol; Paeng, Dong Guk

    2012-01-01

    In the present paper, the ultrasound blood images were measured at both the human radial artery(RA) and common carotid artery(CCA), depending on the age, and the pulsatility index of blood echogenicity(PIBE) was analyzed. In addition, the ultrasound blood images were measured at both RA and CCA of both the stroke patients and the control group, and PIBE was compared. PIBE of RA for the young group was similar with that for the old group (0.13±0.21 and 0.16±0.03). PIBE of CCA for the young group, however, was larger than that for the old group (0.70±0.21 and 0.32±0.01), and was more variable depending on the subject. Similarly, the fibrinogen concentrations of the patients (336±61 and 340±126 mg/dl) were more than that of the control group (264±38 and 43 mg/dl), for both RA and CCA. The results indicate the possibility of the ultrasonic test on the correlation between erythrocyte aggregation and stroke, and it is expected that the in-vivo EA measurement would be clinically useful.

  14. Harmonic scalpel versus electrocautery for harvest of radial artery conduits: Reduced risk of spasm and intimal injury on optical coherence tomography

    Science.gov (United States)

    Brazio, Philip S.; Laird, Patrick C.; Xu, Chenyang; Gu, Junyan; Burris, Nicholas S.; Brown, Emile N.; Kon, Zachary N.; Poston, Robert S.

    2009-01-01

    Objective Vasospasm is the primary obstacle to widespread adoption of the radial artery as a conduit in coronary artery bypass grafting. We used optical coherence tomography, a catheter-based intravascular imaging modality, to measure the degree of radial artery spasm induced by means of harvest with electrocautery or a harmonic scalpel in patients undergoing coronary artery bypass grafting. Methods Radial arteries were harvested from 44 consecutive patients with a harmonic scalpel (n = 15) or electrocautery (n = 29). Vessels were imaged before harvesting and after removal from the arm, with saphenous vein tracts serving as internal controls. Optical coherence tomographic findings for the degree of harvesting-induced injury were validated against histologic measures. Results Optical coherence tomographic measures of endovascular dimensions and injury correlated strongly with histologic findings. Mean luminal volume, a measure of vasospasm, decreased significantly less after harvesting with a harmonic scalpel (9% ± 7%) than with electrocautery (35% ± 6%, P = .015). Completely intact intima was present in 11 (73%) of 15 radial arteries harvested with a harmonic scalpel (73%) compared with 9 of 29 arteries harvested by means of electrocautery (31%, P = .011). Intraoperative flow measurements and patency rates at 5 days postoperatively were not significantly different among groups. Conclusions Optical coherence tomography provides a level of speed and accuracy for quantifying endothelial injury and vasospasm that has not been described for any other modality, suggesting potential as an intraoperative quality assurance tool. Our optical coherence tomographic findings suggest that the harmonic scalpel induces less spasm and intimal injury compared with electrocautery. PMID:19026820

  15. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)-Results of the FERARI study.

    Science.gov (United States)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-12-01

    Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose-area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8min, p=0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p=0.826), procedural duration (46.0 vs. 45.0min, p=0.363) and contrast agent use (185.5 vs. 199.5ml, p=0.742) were also similar in radial and femoral PCI. There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    Energy Technology Data Exchange (ETDEWEB)

    Becher, Tobias, E-mail: Tobias.Becher@umm.de [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); Mashayekhi, Kambis [Division of Cardiology and Angiology II, University Heart Center Freiburg Bad Krozingen, Bad Krozingen (Germany); Borggrefe, Martin; Akin, Ibrahim [First Department of Medicine, University Medical Centre Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany); DZHK (German Centre for Cardiovascular Research), partner site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim (Germany)

    2016-12-15

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use.

  17. Radiation exposure and contrast agent use related to radial versus femoral arterial access during percutaneous coronary intervention (PCI)—Results of the FERARI study

    International Nuclear Information System (INIS)

    Becher, Tobias; Behnes, Michael; Ünsal, Melike; Baumann, Stefan; El-Battrawy, Ibrahim; Fastner, Christian; Kuschyk, Jürgen; Papavassiliu, Theano; Hoffmann, Ursula; Mashayekhi, Kambis; Borggrefe, Martin; Akin, Ibrahim

    2016-01-01

    Summary: Background: Data regarding radiation exposure related to radial versus femoral arterial access in patients undergoing percutaneous coronary intervention (PCI) remain controversial. This study aims to evaluate patients enrolled in the FERARI study regarding radiation exposure, fluoroscopy time and contrast agent use. Methods: The Femoral Closure versus Radial Compression Devices Related to Percutaneous Coronary Interventions (FERARI) study evaluated prospectively 400 patients between February 2014 and May 2015 undergoing PCI either using the radial or femoral access. In these 400 patients, baseline characteristics, procedural data such as procedural duration, fluoroscopy time, dose–area product (DAP) as well as the amount of contrast agent used were documented and analyzed. Results: Median fluoroscopy time was not significantly different in patients undergoing radial versus femoral access (12.2 vs. 9.8 min, p = 0.507). Furthermore, median DAP (54.5 vs. 52.0 Gycm2, p = 0.826), procedural duration (46.0 vs. 45.0 min, p = 0.363) and contrast agent use (185.5 vs. 199.5 ml, p = 0.742) were also similar in radial and femoral PCI. Conclusion: There was no difference regarding median fluoroscopy time, procedural duration, radiation dose or contrast agent use between radial versus femoral arterial access in PCI. - Highlights: • Data comparing radiation exposure in radial versus femoral PCI remain controversial. • 400 enrolled in the FERARI study were prospectively evaluated. • There was no difference regarding radiation exposure in radial versus femoral access. • Furthermore, there was no significant difference regarding contrast agent use

  18. Redundant Vasodilator Pathways Underlying Radial Artery Flow-Mediated Dilation Are Preserved in Healthy Aging

    Directory of Open Access Journals (Sweden)

    Kevin D. Ballard

    2014-01-01

    Full Text Available Background. Blocking nitric oxide (NO and vasodilator prostanoids (PN does not consistently reduce flow-mediated dilation (FMD in young adults. The impact of aging on the contribution of NO and PG to FMD is unknown. Methods. FMD was measured in older adults (n=10, 65±3 y after arterial infusion of saline, N(G-monomethyl-L-arginine (L-NMMA, and ketorolac + L-NMMA. Data were compared to published data in young adults. Results. L-NMMA reduced FMD in older adults (8.9±3.6 to 5.9±3.7% although this was not statistically significant (P=0.08 and did not differ (P=0.74 from the reduction observed in young adults (10.0±3.8 to 7.6±4.7%; P=0.03. Blocking PN did not affect FMD in young or older adults. In older adults, L-NMMA reduced (n=6; range = 36–123% decrease, augmented (n=3; 10–122% increase, or did not change FMD (n=1; 0.4% increase. After PN blockade, FMD responses were reduced (n=2, augmented (n=6, or unaffected (n=1. Conclusions. NO or PN blockade did not consistently reduce FMD in healthy older adults, suggesting the existence of redundant vasodilator phenotypes as observed previously in young adults.

  19. Utilização da artéria radial como segundo enxerto arterial em pacientes acima de 70 anos The use of the radial artery as the second choice for arterial graft in patients over 70 years of age

    Directory of Open Access Journals (Sweden)

    Joseph Fredric Whitaker

    2005-03-01

    Full Text Available OBJETIVO: Estudo retrospectivo para avaliar a morbi-mortalidade e a evolução hospitalar em pacientes com idade superior a 70 anos, submetidos à operação de revascularização do miocárdio com utilização da artéria radial como segundo enxerto arterial. MÉTODO: No período de agosto de 1994 a dezembro de 2002, foram realizadas 2487 cirurgias de revascularização do miocárdio no Instituto do Coração de Juiz de Fora. Dentre os pacientes operados, 476 tinham idade superior a 70 anos, sendo que em 36 (Grupo II foi utilizada a artéria radial como 2º enxerto arterial. O mesmo tipo de cirurgia foi realizado em 142 pacientes com idade inferior a 70 anos (Grupo I. Não foram incluídas neste estudo reoperações, cirurgias sem CEC ou com procedimentos associados. RESULTADOS: A média de idade do Grupo II foi 72,5 anos, a mortalidade hospitalar neste grupo de pacientes foi 6,0%, a incidência de complicações também foi baixa, comparável à observada no mesmo tipo de operação realizada em pacientes com idade inferior a 70 anos. CONCLUSÃO: Diante destes resultados, os autores acreditam que a artéria radial possa ser usada com segurança como 2º enxerto arterial em pacientes acima de 70 anos, criteriosamente selecionados, apesar do maior risco de co-morbidades associadas nesta faixa etária.OBJECTIVE: Retrospective study eveluating the morbid-mortality and hospital behaviour in patients over 70-years -od patients submitted to myocardial revascularization involving the radial artery as the second arterial graft. METHOD: During the period of August 1994 to December 2002, 2487 cases of myocardial revascularization were performed by the group of the Juiz de Fora Heart Institute, 476 of whom were 70 years of age or older and 36 (Group II received the radial artery as the second arterial graft. The same type of surgery was performed in 142 patients under 70-year-old (Group I. Reoperations, off-pump operations (OPCAB or associated procedures

  20. Aneurisma sacular da artéria radial: a propósito de um caso clínico Sacular aneurysm of the radial artery: a case report

    Directory of Open Access Journals (Sweden)

    Nádia Duarte

    2011-06-01

    Full Text Available Os aneurismas da artéria radial são raros e esporádicos, sendo que os pseudoaneurismas são mais frequentes do que os aneurismas verdadeiros e maioritariamente de configuração sacular. A etiologia é variada e diferenciam-se de outros diagnósticos pela pulsação e frémito. Raramente se complicam de ruptura, sendo a trombose e embolização as principais complicações. Dos casos publicados sobre aneurismas verdadeiros da artéria radial, apenas um está descrito como sendo secundário a lesão ocupacional repetitiva, sendo a maioria de causa idiopática. Os autores descrevem um caso de uma mulher de 63 anos, referenciada à consulta de Cirurgia Vascular por crescimento de massa pulsátil na tabaqueira anatómica da mão esquerda. O estudo por eco-doppler e angiografia, confirmaram o diagnóstico de aneurisma sacular da artéria radial, com 20 mm de maior eixo, arcada palmar permeável e sem sinais de embolização distal. Foi submetida a aneurismectomia parcial com laqueação dupla proximal e distal e endoaneurismorrafia. A cirurgia e pós-operatório decorreram sem complicações, nomeadamente complicações isquémicas. A propósito desde caso clínico, discute-se a abordagem diagnóstica e opções terapêuticas.Radial artery aneurysms are sporadic and rare, pseudoaneurysms are more common than true aneurysms, mainly in saccular configuration. The etiology is varied and difference from other diagnostics is done by the presence of pulse and thrill. Thrombosis and embolization are the main complications, while rupture is rare. From the reported cases of true aneurysms of the radial artery, only one is described as being secondary to repetitive occupational injury, the majority being idiopathic. The authors describe the case of a 63 year old woman, referred to a Vascular Surgery consultation because of a growing pulsatile mass in the anatomical snuffbox of the left hand. The Doppler and Angiography studies confirmed the diagnosis of

  1. Morphological and functional consequences of transradial coronary angiography on the radial artery: implications for its use as a bypass conduit.

    Science.gov (United States)

    Gaudino, Mario; Leone, Alessandro; Lupascu, Andrea; Toesca, Amelia; Mazza, Andrea; Ponziani, Francesca Romana; Flore, Roberto; Tondi, Paolo; Massetti, Massimo

    2015-09-01

    To assess the degree of damage to the radial artery (RA) in coronary artery bypass grafting (CABG) patients who underwent preoperative transradial coronary angiography (RA-CA). From May 2012 to October 2013, 50 consecutive CABG patients who underwent RA-CA were prospectively enrolled in the study. All patients underwent echo-Doppler evaluation of the RA of the catheterized arm; the contralateral RA was used as control. The distal segment of the RA was submitted to immunohistochemical assessment of endothelial integrity. Patients were divided in three groups according to the time interval from angiography to evaluation: ≤24 h, >24 h to <7 days and ≥7 days. Baseline RA median diameters were 0.25 ± 0.04 cm in the cannulated arm and 0.22 ± 0.04 cm in the non-cannulated arm (P = 0.01). The flow-mediated dilatation (FMD) in the RA in the catheterized arm and in the control arm were 11.6 ± 7.9 and 14.2 ± 8.9 (P = 0.01), respectively. A statistically significant correlation was found between FMD of the catheterized RA and the time from RA-CA (Pearson's r = 0.348). Linear regression analysis confirmed that the FMD of the catheterized RA was dependent on days elapsed from the procedure (P = 0.032; OR 1.11, CI 0.009-0.203). Immunohistochemical evaluation showed extensive endothelial lesion in all examined RAs, with a trend towards reduction of the damage with time. Endothelial function and integrity of the cannulated arm did not reach those of the control arm in any of the study patients. RA-CA produces extensive damage to the RA. The lesions tend to heal with time but incomplete recovery of endothelial integrity and function is still present more than 30 days after the procedure. After RA-CA, the cannulated RA should not be used for CABG. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  2. Regression analysis of radial artery pulse palpation as a potential tool for traditional Chinese medicine training education.

    Science.gov (United States)

    Huang, Po-Yu; Lin, Wen-Chen; Chiu, Bill Yuan-Chi; Chang, Hen-Hong; Lin, Kang-Ping

    2013-12-01

    Pulse palpation was an important part of the traditional Chinese medicine (TCM) vascular examination. It is challenging for new physicians to learn to differentiate between palpations of various pulse types, due to limited comparative learning time with established masters, and so normally it takes many years to master the art. The purpose of this study was to introduce an offline TCM skill evaluation and comparison system that makes available learning of palpation without the master's presence. We record patient's radial artery pulse using an existing pressure-based pulse acquisition system, then annotate it with teachers' evaluation when palpating the same patient, assigned as likelihood of it being each pulse type, e.g. wiry, slippery, hesitant. These training data were separated into per-doctor and per-skill databases for evaluation and comparison purposes, using the following novel procedure: each database was used as training data to a panel of time-series data-mining algorithms, driven by two validation tests, with the created training models evaluated in mean-squared-error. Each validation of the panel and training data yielded an array of error terms, and we chose one to quantitatively evaluate palpation techniques, giving way to compute self consistency and mutual-similarity across different practitioners and techniques. Our experiment of two practitioners and 396 per-processing samples yielded the following: one of the physicians has much higher value of self-consistency for all tested pulse types. Also, the two physicians have high similarity in how they palpate the slipper pulse (P) type, but very dissimilar for hesitant (H) type. This system of skill comparisons may be more broadly applied in places where supervised learning algorithms can detect and use meaningful features in the data; we chose a panel of algorithms previously shown to be effective for many time-series types, but specialized algorithms may be added to improve feature-specific aspect

  3. Comparação da perviedade entre artéria radial e veia safena em pacientes em pós-operatório de cirurgia de revascularização miocárdica com retorno dos sintomas Comparison of patency between radial artery and saphenous vein in a coronary artery bypass grafting post operative with return of the symptoms

    Directory of Open Access Journals (Sweden)

    Herbert Coelho Hortmann

    2010-06-01

    Full Text Available OBJETIVO: Comparar a perviedade da artéria radial e veia safena em pacientes com retorno dos sintomas após cirurgia de revascularização do miocárdio (CRVM. MÉTODOS: Estudo retrospectivo. No período de janeiro de 1998 a dezembro de 2005, foram realizadas 469 CRVMs com o uso da artéria radial dentre os enxertos, no Hospital Vera Cruz, em Belo Horizonte/MG. Destes, 94 pacientes apresentaram alterações isquêmicas no pós-operatório recente ou tardio e foram reestudados com cineangiocoronariografia. Os enxertos foram divididos em três grupos: artéria torácica interna (ATI, artéria radial (AR e veia safena (VS, e foram estratificados segundo a gravidade das lesões: sem lesão grave (OBJECTIVE: To compare the radial artery and saphenous vein's patency in patients with recurrence of symptoms in a coronary artery bypass grafting (CABG. METHODS: Retrospective study. From January 1998 to December 2005, 469 CABGs were performed using the radial artery as a graft, in Vera Cruz Hospital in Belo Horizonte/ MG. Among the patients who underwent those surgeries, 94 presented ischemic changes in early or late postoperative period, which led them to be re-evaluated by coronary angiography. The grafts were divided in three groups: internal thoracic artery (ITA, radial artery (RA and saphenous vein (SV, and they were stratified according to the severity of injury: uninjured or patent (< 70%, severe obstruction (70 to 99% and occlusion. RESULTS: For the 94 patients in the study, 86 grafts of ITA, 94 of RA and 111 of SV were used. For the 86 ITA grafts, 73 (84.88% were found patent. For the 94 RA grafts, 55 (58.51% were found patent, and for the 111 SV grafts, 73 (65.76% were uninjured. A statistically significant difference (P= 0.001 was found between RA and SV grafts, with a higher patency found for VS graft. For the RA grafts, women presented a worse result concerning the RA patency (65.7% and 40.7%, with P = 0.006. Concerning coronary

  4. Radial Artery Catheterization

    Science.gov (United States)

    ... Circulation My alerts Sign In Join Sign out Facebook Twitter Home About this Journal Editorial Board General Statistics Circulation Doodle Information for Advertisers Author Reprints Commercial Reprints Customer Service and Ordering ...

  5. Association of clinical androgen excess with radial artery intima media thickness in women with polycystic ovary syndrome.

    Science.gov (United States)

    Yilmaz, S A; Kebapcilar, A; Koplay, M; Kerimoglu, O S; Pekin, A T; Gencoglu, B; Dogan, N U; Celik, C

    2015-06-01

    This study explores the relationship between clinical cardiovascular risk factors and clinical androgen excess, with direct comparison to radial artery intima media thickness (rIMT). rIMT of 91 patients with polycystic ovary syndrome (PCOS) were compared with 72 healthy women. Patients were divided into three groups with regard to body mass index (BMI). Group1 = 56 women (31 controls and 25 PCOS) with low BMI(18-22.49 kg/m(2)), Group2 = 36 women (15 controls and 21 PCOS) with normal BMI (22.5-24.99 kg/m(2)) and Group3 = 71 women (26 controls and 45 PCOS) with high BMI (25-30 kg/m(2)). rIMT was significantly higher in patients with PCOS (p = 0.007). rIMT was significantly higher group1 and group3 in patients with PCOS compared to controls (p = 0.007 and p = 0.042, respectively). There was a significant positive association between rIMT levels and fT in women with PCOS in group1 (r = 0.24, p = 0.04). rIMT levels correlated to fT levels in women with PCOS in group3 (r = 0.32, p = 0.03). Modified Ferriman-Gallwey (mFG) scores demonstrated a positive association with free testosterone, total testosterone, free androgen index, waist circumference (WC), LH levels, insulin levels, Homeostasis Model Assessment index(HOMA-IR), rIMT and a negative correlation with sex hormone binding globulin in group1 and group2. mFG scores demonstrated a positive association with free testosterone (r = 0.33, p = 0.029) in group3, but no association was found between mFG and WC, HOMA-IR in group3. Our findings indicate that clinical androgen excess may be associated with cardiovascular disease in patients with PCOS.

  6. Identifying factors that predict the choice and success rate of radial artery catheterisation in contemporary real world cardiology practice: a sub-analysis of the PREVAIL study data.

    Science.gov (United States)

    Pristipino, Christian; Roncella, Adriana; Trani, Carlo; Nazzaro, Marco S; Berni, Andrea; Di Sciascio, Germano; Sciahbasi, Alessandro; Musarò, Salvatore Donato; Mazzarotto, Pietro; Gioffrè, Gaetano; Speciale, Giulio

    2010-06-01

    To assess: the reasons behind an operator choosing to perform radial artery catheterisation (RAC) as against femoral arterial catheterisation, and to explore why RAC may fail in the real world. A pre-determined analysis of PREVAIL study database was performed. Relevant data were collected in a prospective, observational survey of 1,052 consecutive patients undergoing invasive cardiovascular procedures at nine Italian hospitals over a one month observation period. By multivariate analysis, the independent predictors of RAC choice were having the procedure performed: (1) at a high procedural volume centre; and (2) by an operator who performs a high volume of radial procedures; clinical variables played no statistically significant role. RAC failure was predicted independently by (1) a lower operator propensity to use RAC; and (2) the presence of obstructive peripheral artery disease. A 10-fold lower rate of RAC failure was observed among operators who perform RAC for > 85% of their personal caseload than among those who use RAC < 25% of the time (3.8% vs. 33.0%, respectively); by receiver operator characteristic (ROC) analysis, no threshold value for operator RAC volume predicted RAC failure. A routine RAC in all-comers is superior to a selective strategy in terms of feasibility and success rate.

  7. Evaluation of Two Miniplate Systems and Figure-of-eight Bandages for Stabilization of Experimentally Induced Ulnar and Radial Fractures in Pigeons ( Columba livia ).

    Science.gov (United States)

    Bennert, Beatrice M; Kircher, Patrick R; Gutbrod, Andreas; Riechert, Juliane; Hatt, Jean-Michel

    2016-06-01

    Although plate fixation has advantages over other fixation methods for certain indications, it is rarely used in avian surgery, especially in birds that weigh less than 1000 g. Exceptionally small plating systems for these birds are required, which are relatively expensive and difficult to insert. To study avian fracture healing after repair using miniplates, we evaluated 2 steel miniplate systems in 27 pigeons ( Columba livia ) divided into 4 groups. In each pigeon, the left ulna and radius were transected and the ulna was repaired with a bone plate. In groups A and B, a 1.3-mm adaption plate was applied without and with a figure-of-eight bandage; in groups C and D, a 1.0-mm compression plate was applied without and with a bandage, respectively. Healing was evaluated with radiographs after 3, 14, and 28 days; flight tests were conducted after 14, 21, and 28 days; and the wing was macroscopically examined after euthanasia of birds on day 28. Fractures healed without bending or distortion of the plate in all 27 birds, and no significant differences in healing were found between treatment groups. At the end of the study, 23 pigeons (85.2%) showed good or very good flight ability. Results show the 1.3-mm adaption plate and the 1.0-mm compression plate meet the requirements for avian osteosynthesis and can be recommended for fracture repair of the ulna or other long bones in birds weighing less than 500 g. The application of a figure-of-eight bandage might be beneficial in fracture healing.

  8. Figure5

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is an R statistics package script that allows the reproduction of Figure 5. The script includes the links to large NetCDF files that the figures access for O3,...

  9. Figure 7

    Data.gov (United States)

    U.S. Environmental Protection Agency — Two files provided. The ENS.tar file contains text data files (*.csv) used to create Figure 7 and Figure 8. The Figure7.txt is an R script that reads these files and...

  10. Coronary artery assessment using self-navigated free-breathing radial whole-heart magnetic resonance angiography in patients with congenital heart disease

    Energy Technology Data Exchange (ETDEWEB)

    Albrecht, Moritz H. [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany); Varga-Szemes, Akos; Schoepf, U.J.; Xu, Jiaqian; Jin, Kwang-Nam; Hlavacek, Anthony M.; Chowdhury, Shahryar M.; Suranyi, Pal; Tesche, Christian; De Cecco, Carlo N.; Nutting, Arni [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); Apfaltrer, Georg [Medical University of South Carolina, Department of Radiology and Radiological Science, Division of Cardiovascular Imaging, Charleston, SC (United States); University Hospital Graz, Department of Radiology, Graz (Austria); Piccini, Davide [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Siemens Healthcare, IM BM PI, Advanced Clinical Imaging Technology, Lausanne (Switzerland); Stuber, Matthias; Ginami, Giulia [University Hospital of Lausanne (CHUV), Department of Radiology, Centre for Biomedical Imaging (CIBM), Lausanne (Switzerland); Vogl, Thomas J. [University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Frankfurt (Germany)

    2018-03-15

    To evaluate a self-navigated free-breathing three-dimensional (SNFB3D) radial whole-heart MRA technique for assessment of main coronary arteries (CAs) and side branches in patients with congenital heart disease (CHD). SNFB3D-MRA datasets of 109 patients (20.1±11.8 years) were included. Three readers assessed the depiction of CA segments, diagnostic confidence in determining CA dominance, overall image quality and the ability to freeze cardiac and respiratory motion. Vessel sharpness was quantitatively measured. The percentages of cases with excellent CA depiction were as follows (mean score): left main, 92.6 % (1.92); left anterior descending (LAD), 88.3 % (1.88); right (RCA), 87.8 % (1.85); left circumflex, 82.8 % (1.82); posterior descending, 50.2 % (1.50) and first diagonal, 39.8 % (1.39). High diagnostic confidence for the assessment of CA dominance was achieved in 56.2 % of MRA examinations (mean score, 1.56). Cardiac motion freezing (mean score, 2.18; Pearson's r=0.73, P<0.029) affected image quality more than respiratory motion freezing (mean score, 2.20; r=0.58, P<0.029). Mean quantitative vessel sharpness of the internal thoracic artery, RCA and LAD were 53.1, 52.5 and 48.7 %, respectively. Most SNFB3D-MRA examinations allow for excellent depiction of the main CAs in young CHD patients; visualisation of side branches remains limited. (orig.)

  11. Figure 3

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Figure.tar.gz contains a directory for each WRF ensemble run. In these directories are *.csv files for each meteorology variable examined. These are comma...

  12. Figure6

    Data.gov (United States)

    U.S. Environmental Protection Agency — R script for the reproduction of Figure6. This script accesses archived CMAQ and WRF model output on US EPA's HPC sol computer system and plots forward trajectories...

  13. Aerobic exercise intensity can be controlled by palpation of the radial artery DOI:10.5007/1980-0037.2010v12n3p186

    Directory of Open Access Journals (Sweden)

    Anselmo José Perez

    2010-01-01

    Full Text Available Heart rate (HR during exercise has been used for the control of aerobic exercise intensity. Palpation is the most popular and accessible method for this purpose. The responses obtained in laboratory tests are used for field application and are suggested to be similar. The objective of this study was to correlate the HR measures obtained by palpation and with a heart rate monitor (HRM in four sessions of aerobic exercise, and to compare the results obtained in the laboratory and in the field. Fifteen healthy young women underwent four sessions of aerobic training of 40 min each at a continuous load, including two sessions on a treadmill and two in the field (50-60% and 80-85% HRmax. During the sessions, HR was recorded minute-by-minute with an HRM (Polar Accurex and measured at 10-minute intervals by pulse palpation. There were significant differences in ∆HR values obtained by palpation and with the HRM between exercise sessions performed on the track and in the laboratory. Strong correlations (r = 0.95 and moderate to strong (r = 0.73 correlations were observed between palpation and HRM in the four sessions. HR during exercise obtained by palpation was underestimated by no more than 5%, but there were no significant differences in mean absolute HR measured by HRM and palpation. For the same exercise intensity, similar results are obtained in the field and laboratory. In addition, HR obtained by palpation of the radial artery immediately after exercise can be used for the control of aerobic exercise intensity.

  14. Non-gated vessel wall imaging of the internal carotid artery using radial scanning and fast spin echo sequence. Evaluation of vessel signal intensity by flow rate at 3.0 tesla

    International Nuclear Information System (INIS)

    Nakamura, Manami; Makabe, Takeshi; Ichikawa, Masaki; Hatakeyama, Ryohei; Sugimori, Hiroyuki; Sakata, Motomichi

    2013-01-01

    Vessel wall imaging using radial scanning does not use a blood flow suppression pulse with gated acquisition. It has been proposed that there may not be a flow void effect if the flow rate is slow; however, this has yet to be empirically tested. To clarify the relationship between the signal intensity of the vessel lumen and the blood flow rate in a flow phantom, we investigated the usefulness of vessel wall imaging at 3.0 tesla (T). We measured the signal intensity while changing the flow rate in the flow phantom. Radial scanning at 1.5 T showed sufficient flow voids at above medium flow rates. There was no significant difference in lumen signal intensity at the carotid artery flow rate. The signal intensity of the vessel lumen decreased sufficiently using the radial scan method at 3.0 T. We thus obtained sufficient flow void effects at the carotid artery flow rate. We conclude this technique to be useful for evaluating plaque if high contrast can be maintained for fixed tissue (such as plaque) and the vessel lumen. (author)

  15. Double profunda brachii artery

    Directory of Open Access Journals (Sweden)

    Gavishiddappa A Hadimani

    2016-01-01

    Full Text Available Brachial artery (BA is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii artery 2 arises distal to the profunda brachii artery 1. Both the arteries run inferolaterally in the spiral groove along with radial nerve. Variations of profunda brachii artery are important during harvesting of the lateral arm flaps and may lead to inadvertent injury during percutaneous arterial catheterization or injection of drugs.

  16. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  17. Comparison of Safety and Effectiveness Between Right Versus Left Radial Arterial Access in Primary Percutaneous Coronary Intervention for Acute ST Segment Elevation Myocardial Infarction.

    Science.gov (United States)

    Elmahdy, Mahmoud Farouk; ElMaghawry, Mohamed; Hassan, Mohamed; Kassem, Hussien Heshmat; Said, Karim; Elfaramawy, Amr AbdelAziz

    2017-01-01

    Transradial approach (TRA) is now considered the standard of care in many centres for elective and primary percutaneous intervention (PCI). The use of the radial approach in ST segment elevation myocardial infarction (STEMI) patients has been associated with a significant reduction in major adverse cardiac events. However, it is still unclear if the side of radial access (right vs. left) has impact on safety and effectiveness of TRA in primary PCI. So this study was conducted to compare the safety, feasibility, and outcomes of right radial access (RRA) vs. left radial access (LRA) in the setting of primary PCI. We retrospectively analysed the data of 400 consecutive patients presenting to our institution with STEMI for whom primary PCIs were performed via RRA and LRA. Mean age of the whole studied population was 57±12.8 years, with male predominance (77.2%). There were 202 cases in the RRA group and 198 in the LRA group, with no significant difference in demographics and clinical characteristics for patients included in both groups. There was no significant difference in procedure success rate (97.5% for RRA vs. 98.4% for LRA; P=0.77). In addition, no significant difference between both approaches was observed in the contrast volume, number of catheters, fluoroscopy time (FT), needle-to-balloon time, post-procedure vascular complications, in hospital reinfarction, stroke/transient ischaemic attack (TIA) or death. Right radial access and LRA are equally safe and effective in the setting of primary PCI. Both approaches have a high success rate and comparable needle-to-balloon time. Copyright © 2016 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  18. Radial pseudoaneurysm following diagnostic coronary angiography

    Directory of Open Access Journals (Sweden)

    Shankar Laudari

    2015-06-01

    Full Text Available The radial artery access has gained popularity as a method of diagnostic coronary catheterization compared to femoral artery puncture in terms of vascular complications and early ambulation. However, very rare complication like radial artery pseudoaneurysm may occur following cardiac catheterization which may give rise to serious consequences. Here, we report a patient with radial pseudoaneurysm following diagnostic coronary angiography. Adequate and correct methodology of compression of radial artery following puncture for maintaining hemostasis is the key to prevention.DOI: http://dx.doi.org/10.3126/jcmsn.v10i3.12776 Journal of College of Medical Sciences-Nepal, 2014, Vol-10, No-3, 48-50

  19. Double profunda brachii artery

    OpenAIRE

    Gavishiddappa A Hadimani; Jyoti V Hadimani; Ishwar B Bagoji; Shardha Bai Rathod; Balappa M Bannur

    2016-01-01

    Brachial artery (BA) is a continuation of the axillary artery at the lower border of teres major. In the cubital fossa, BA divides into radial artery and ulnar artery as terminal branches. Large branch given from the BA in the upper part is profunda brachii artery. In the present case, we noticed double profunda brachii that arises from the BA. They are profunda brachii artery 1 and profunda brachii artery 2. Profunda brachii artery 1 arises in the proximal part of the BA and profunda brachii...

  20. Variations in the usage and composition of a radial cocktail during radial access coronary angiography procedures.

    LENUS (Irish Health Repository)

    Pate, G

    2011-10-01

    A survey was conducted of medication administered during radial artery cannulation for coronary angiography in 2009 in Ireland; responses were obtained for 15 of 20 centres, in 5 of which no radial access procedures were undertaken. All 10 (100%) centres which provided data used heparin and one or more anti-spasmodics; verapamil in 9 (90%), nitrate in 1 (10%), both in 2 (20%). There were significant variations in the doses used. Further work needs to be done to determine the optimum cocktail to prevent radial artery injury following coronary angiography.

  1. Radial nerve dysfunction

    Science.gov (United States)

    Neuropathy - radial nerve; Radial nerve palsy; Mononeuropathy ... Damage to one nerve group, such as the radial nerve, is called mononeuropathy . Mononeuropathy means there is damage to a single nerve. Both ...

  2. Técnica para retirada da artéria radial sem utilização de clipes hemostáticos e experiência clínica Radial artery harvesting technique without hemostatic clips and clinical experience

    Directory of Open Access Journals (Sweden)

    João Bosco de Oliveira

    2008-03-01

    Full Text Available OBJETIVO: As diferentes técnicas de dissecção de artéria radial (AR obtêm resultados semelhantes. Estas técnicas utilizam eletrocautério, bisturi ultra-sônico ou tesouras em diferentes combinações, mas geralmente associadas ao uso de clipes hemostáticos. Este trabalho descreve uma técnica de dissecção de AR com a combinação de tesouras e eletrocautério sem o uso de clipes hemostáticos. MÉTODOS: O estudo apresenta um levantamento retrospectivo de 107 pacientes, entre 28 e 78 anos (média ± desvio padrão 53,3 ± 8 anos, feito entre janeiro de 2000 e junho de 2005, no qual é relatada a incidência de sangramento, reoperação, infarto do miocárdio e mortalidade. RESULTADOS: Não ocorreram sangramentos relacionados à AR e não ocorreram reoperações. Ocorreram três (2,8% infartos possivelmente relacionados ao território de anastomose de AR. A mortalidade foi de 0,9% não relacionada a causas cardiovasculares. CONCLUSÃO: A dissecção de AR com eletrocautério sem clipes hemostáticos não apresentou sangramento, foi de baixo custo e dispensa investimentos em equipamentos adicionais.OBJECTIVE: The various techniques of radial artery (RA harvesting produce similar results. These techniques use electrocautery, ultrasonic scalpel, or sharp scissors in different combinations, but usually associated with the use of hemostatic clips. We describe a RA harvesting technique with the combination of sharp scissors and electrocautery without the use of hemostatic clips. METHODS: We describe a retrospective study of 107 patients ranging from 28 and 78 years of age (mean ± SD; 53.3 ± 8 yrs. Bleeding, re-operation, infarct, and death were analyzed. RESULTS: No bleeding was imputable to the RA and no re-operations were required. There were three (2.8% infarcts possibly related to the RA anastomosis territory. Mortality was 0.9%, but unrelated to cardiac complications. CONCLUSION: RA electrocautery harvesting without hemostatic clips

  3. Student figures in friction

    DEFF Research Database (Denmark)

    Nielsen, Gritt B.

    , students' room for participation in their own learning, influenced by demands for efficiency, flexibility and student-centred education. The thesis recasts the anthropological endeavour as one of ‘figuration work'. That is, ‘frictional events' are explored as moments when conflicting figures...

  4. Figure S1 Figure S2

    Indian Academy of Sciences (India)

    WINTEC

    6.8. 7.0. 7.2. 7.4. 7.6. 7.8. 8.0. 8.2. 8.4. 8.6. 8.8 ppm. 0.0. 1.8. 9.7. 5.4. 6.9. 8.1. 9.0. 10.8. 3.2. 10.3. Figure S3. NMR titration of DAN-Ia acid with NDI at 30% MeOH in CDCl3. The numbers represent the mole ratios of the DAN-acid to the repeat unit.

  5. data for figures

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figures 1-10 and Table 1. This dataset is associated with the following publication: Chang, S.Y., S. Arunachalam, A. Valencia, B. Naess, V. Isakov , M. Breen , T....

  6. Figure_2_data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Data for Figure 2. This dataset is associated with the following publication: Sarwar, G., D. Kang, K. Foley, D. Schwede, B. Gantt, and R. Mathur. Technical note:...

  7. Facts and Figures

    Science.gov (United States)

    ... Saves Lives Facts & Figures My Blood, Your Blood Blood Donation Types Did you know there is more than one type of blood donation? Learn more about blood donation types here. Blood Safety and Testing The blood supply ...

  8. Adventures with Lissajous Figures

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2018-06-01

    Lissajous Figures are produced by combining two oscillations at right angles to each other. The figures, drawn by mechanical devices called harmonographs, have scientific uses, but are also enjoyed for their own beauty. The author has been working with harmonographs since his undergraduate days, building several of them, lecturing on them and has written articles about them. This book is intended for people who enjoy physics or art or both.

  9. Graphics of polar figure

    International Nuclear Information System (INIS)

    Macias B, L.R.

    1991-11-01

    The objective of this work, is that starting from a data file coming from a spectra that has been softened, and of the one that have been generated its coordinates to project it in stereographic form, to create the corresponding polar figure making use of the Cyber computer of the ININ by means of the GRAPHOS package. This work only requires a Beta, Fi and Intensity (I) enter data file. It starts of the existence of a softened spectra of which have been generated already with these data, making use of some language that in this case was FORTRAN for the Cyber computer, a program is generated supported in the Graphos package that allows starting of a reading of the Beta, Fi, I file, to generate the points in a stereographic projection and that it culminates with the graph of the corresponding polar figure. The program will request the pertinent information that is wanted to capture in the polar figure just as: date, name of the enter file, indexes of the polar figure, number of levels, radio of the stereographic projection (cms.), crystalline system to which belongs the sample, name the neuter graph file by create and to add the own general data. (Author)

  10. Radial oxygen gradients over rat cortex arterioles

    OpenAIRE

    Galler, Michael

    2011-01-01

    Purpose: We present the results of the visualisation of radial oxygen gradients in rats’ cortices and their use in neurocritical management. Methods: PO2 maps of the cortex of 10 wistar rats were obtained with a camera (SensiMOD, PCO, Kehlheim, Germany). Those pictures were analyzed and edited by a custom-made software. We chose a vessel for examination. A matrix, designed to evaluate the cortical O2 partial pressure, was placed vertically to the artery and afterwards multiple regio...

  11. Forearm arterial anatomy and flow characteristics: a prospective observational study.

    Science.gov (United States)

    Pancholy, Samir B; Heck, Laura A; Patel, Tejas

    2015-04-01

    Morphometric data on Caucasian radial and ulnar arteries are limited, with no data on flow interdependence in the forearm arterial circuit. A total of 250 upper extremities in 125 patients were evaluated. Ultrasonography was performed and radial and ulnar artery lumen diameters were measured. Ulnar artery (UA) was compressed at the level of the wrist, and flow parameters in radial artery (RA) were recorded using duplex Doppler ultrasound. Radial and ulnar artery diameters were comparable at the level of the distal forearm (RA = 2.03 ± 0.28 mm, UA = 2.07 ± 0.27 mm; P=.14). There was no significant difference in radial or ulnar artery diameter between the dominant upper extremity and the non-dominant upper extremity. Upon compression of the ulnar artery, radial artery velocity-time integral (VTI) increased from 8.4 ± 3.8 cm to 12.8 ± 5.5 cm, which was statistically significant (Pforearm is comparable to UA. RA-VTI and likely flow significantly increase by compression of the UA. The smaller the radial artery, the larger the increase in radial artery flow with ulnar compression.

  12. Figures on petroleum 1981

    Energy Technology Data Exchange (ETDEWEB)

    1981-01-01

    This table taken out from the 1981 annual report 1981 contains an introductory remark on the reorganization of mineral oil statistics up to January 82. It is followed by the tables ranged as follows: refinery capacity and production, crude oil supply, GDR-coverings, import of petroleum products, petroleum consumption, export of petroleum products, transport, oil storage tanks, motor vehicle stock, taxes and tariffs, petroleum export trade, energy consumption and world petroleum numbers. In parts the tables contain comparative figures back to 1950.

  13. Massive cerebral arterial air embolism following arterial catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, C.W. [Northwestem University Feinberg School of Medicine, Department of Radiology, Chicago, IL (United States); Yang, B.P. [Northwestern University Feinberg School of Medicine, Department of Neurological Surgery, Chicago, IL (United States)

    2005-12-01

    Microscopic cerebral arterial air embolism (CAAE) has been described in many patients undergoing cardiac surgery as well as other invasive diagnostic and therapeutic procedures. However, massive CAAE is rare. We report a 42-year-old woman who initially presented with thalamic and basal ganglia hemorrhages. Shortly after a radial arterial catheter was inserted, the patient suffered a generalized seizure and CT demonstrated intra-arterial air in bilateral cerebral hemispheres. (orig.)

  14. PUBLIK FIGUR DALAM IKLAN TESTIMONIAL

    Directory of Open Access Journals (Sweden)

    Deddi Duto Hartanto

    2000-01-01

    Full Text Available Testimonial advertising seemingly identical with famous figure such as artist%2C sportmen or others. They are all branded as "public figure" because they are well known by public. A lot of advertising creators using public figure in order to gain a high brand awareness. Is the use of public figure in testimonial advertising more profitable? Is their able quite representative for the products they represent ? Abstract in Bahasa Indonesia : Iklan testimonial identik dengan tokoh terkenal%2C baik itu artis%2C tokoh masyarakat%2C olahragawan%2C atau yang lainnya. Semuanya di cap sebagai "publik figur%2C" karena sudah dikenal masyarakat.Banyak kreator iklan menggunakan publik figur dengan harapan dapat mencapai brand awareness yang tinggi. Apakah penggunaan publik figur dalam iklan testimonial lebih menguntungkan ?%2C Apakah peran publik figur (sudah mewakili produk yang dibawakan?. testimonial advertising%2C public figure

  15. Figure out the Rhythm

    DEFF Research Database (Denmark)

    Knakkergaard, Martin

    Thinking in numbers, figures and systems plays a central part in our - at least scientific – understanding of musical matters. The kind of pre-order that the numbers - and also the systemic thinking - bring along seem to facilitate the access to and dealings with what we understand as fundamental...... to reflect. By means of a critical resume of an earlier analysis of rhythmical implications in Michael Jackson's "Give In To Me" this paper discusses these matters further and reflects upon arithmetic's influences and relevance for our understanding of music....

  16. Facts and figures

    International Nuclear Information System (INIS)

    1987-01-01

    Whereas most of the data are, naturally, about oil, a few figures concern nuclear energy. There is in Part 1 a flow chart of worldwide primary energy consumption by type, from 1974 to 1986, where nuclear energy consumption can be seen in relation to oil, gas, coal and hydro. The same is also given for the regions of the South. In section 3/18 the numbers of nuclear plants in construction and operation are listed separately for developing countries, centrally planned economies and industrialized countries, for 1986. (qui)

  17. Radial nerve dysfunction (image)

    Science.gov (United States)

    The radial nerve travels down the arm and supplies movement to the triceps muscle at the back of the upper arm. ... the wrist and hand. The usual causes of nerve dysfunction are direct trauma, prolonged pressure on the ...

  18. Automatic figure ranking and user interfacing for intelligent figure search.

    Directory of Open Access Journals (Sweden)

    Hong Yu

    2010-10-01

    Full Text Available Figures are important experimental results that are typically reported in full-text bioscience articles. Bioscience researchers need to access figures to validate research facts and to formulate or to test novel research hypotheses. On the other hand, the sheer volume of bioscience literature has made it difficult to access figures. Therefore, we are developing an intelligent figure search engine (http://figuresearch.askhermes.org. Existing research in figure search treats each figure equally, but we introduce a novel concept of "figure ranking": figures appearing in a full-text biomedical article can be ranked by their contribution to the knowledge discovery.We empirically validated the hypothesis of figure ranking with over 100 bioscience researchers, and then developed unsupervised natural language processing (NLP approaches to automatically rank figures. Evaluating on a collection of 202 full-text articles in which authors have ranked the figures based on importance, our best system achieved a weighted error rate of 0.2, which is significantly better than several other baseline systems we explored. We further explored a user interfacing application in which we built novel user interfaces (UIs incorporating figure ranking, allowing bioscience researchers to efficiently access important figures. Our evaluation results show that 92% of the bioscience researchers prefer as the top two choices the user interfaces in which the most important figures are enlarged. With our automatic figure ranking NLP system, bioscience researchers preferred the UIs in which the most important figures were predicted by our NLP system than the UIs in which the most important figures were randomly assigned. In addition, our results show that there was no statistical difference in bioscience researchers' preference in the UIs generated by automatic figure ranking and UIs by human ranking annotation.The evaluation results conclude that automatic figure ranking and user

  19. Figure mining for biomedical research.

    Science.gov (United States)

    Rodriguez-Esteban, Raul; Iossifov, Ivan

    2009-08-15

    Figures from biomedical articles contain valuable information difficult to reach without specialized tools. Currently, there is no search engine that can retrieve specific figure types. This study describes a retrieval method that takes advantage of principles in image understanding, text mining and optical character recognition (OCR) to retrieve figure types defined conceptually. A search engine was developed to retrieve tables and figure types to aid computational and experimental research. http://iossifovlab.cshl.edu/figurome/.

  20. Making better scientific figures

    Science.gov (United States)

    Hawkins, Ed; McNeall, Doug

    2016-04-01

    In the words of the UK government chief scientific adviser "Science is not finished until it's communicated" (Walport 2013). The tools to produce good visual communication have never been so easily accessible to scientists as at the present. Correspondingly, it has never been easier to produce and disseminate poor graphics. In this presentation, we highlight some good practice and offer some practical advice in preparing scientific figures for presentation to peers or to the public. We identify common mistakes in visualisation, including some made by the authors, and offer some good reasons not to trust defaults in graphics software. In particular, we discuss the use of colour scales and share our experiences in running a social media campaign (http://tiny.cc/endrainbow) to replace the "rainbow" (also "jet", or "spectral") colour scale as the default in (climate) scientific visualisation.

  1. Preliminary figures for 1991

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Neste Corporation's net sales during 1991 totalled USD 12.6 billion, an increase of 11 % over the figure for 1990. The largest growth in net sales took place in Neste Oil's trading activities and sales of in-house-produced crude oil. In the chemicals sector. particular growth was recorded in resins production. Gas, Shipping and Exploration and Production performed slightly better than during 1990. Oil's performance remained satisfactory. The performance of Chemicals, however, fell back considerably, primarily, as a result of the worldwide drop in prices in the petrochemicals and plastics industries. As a result, the Corporation's overall result was substantially below the good level recorded in 1990. The Corporation's operating margin totalled USD 650 million

  2. Cybersecurity Figure of Merit

    Science.gov (United States)

    2016-04-30

    Space and Naval Warfare Systems Command The Cybersecurity Challenge in Acquisition Sonia Kaestner, Adjunct Professor, McDonough School of Business ...qÜáêíÉÉåíÜ=^ååì~ä= ^Åèìáëáíáçå=oÉëÉ~êÅÜ= póãéçëáìã= tÉÇåÉëÇ~ó=pÉëëáçåë= sçäìãÉ=f= = Cybersecurity Figure of Merit CAPT Brian Erickson, USN, SPAWAR...the Acquisition Research Program of the Graduate School of Business & Public Policy at the Naval Postgraduate School. To request defense acquisition

  3. Radial wedge flange clamp

    Science.gov (United States)

    Smith, Karl H.

    2002-01-01

    A radial wedge flange clamp comprising a pair of flanges each comprising a plurality of peripheral flat wedge facets having flat wedge surfaces and opposed and mating flat surfaces attached to or otherwise engaged with two elements to be joined and including a series of generally U-shaped wedge clamps each having flat wedge interior surfaces and engaging one pair of said peripheral flat wedge facets. Each of said generally U-shaped wedge clamps has in its opposing extremities apertures for the tangential insertion of bolts to apply uniform radial force to said wedge clamps when assembled about said wedge segments.

  4. Foster replantation of fingertip using neighbouring digital artery in a young child.

    Science.gov (United States)

    Xu, Jing-Hong; Gao, Zheng-Jun; Yao, Jing-Ming; Tan, Wei-Qiang; Dawreeawo, Javed

    2010-06-01

    Reconstruction of an amputated fingertip in a young child demands special techniques for success. We report a 2.5-year-old female patient with an amputated left index fingertip with the vascular defect being too severe to perform the usual replantation. Comparing several methods, we used the neighbouring digital artery as the feeding artery to perform foster replantation. Finally, the patient was satisfied with the appearance and function of her fingers. The clinical case, techniques, results are described and discussed. We consider it a useful technique, especially for those with a rather severe vascular defect. A 2.5-year-old girl suffered a crush amputation of the left index fingertip. Only the flexor tendon of the amputated fingertip was connected to the proximal finger tissue and the blood supply was completely lost (Figure 1). The distal amputated fingertip was fixed using Kirschner wire under general anaesthesia. Then, microsurgery operation was carried out immediately to replant this amputated fingertip. Both ulnar and radial digital arteries were avulsed, while the dorsal vein was intact and the digital nerve was also surviving. The integrity of blood vessels was too traumatised to connect to the proximal part. In the case of the distal part of the ulnar artery of the injured index finger, the blood supply was established by anastomosing the distal end of the amputated tip and the radial artery of the middle finger, which was the feeding artery (Figure 2). A 11/0 nylon suture was used. The dorsal vein and digital nerve were repaired by means of microsurgical anastomosis. The wound was covered with the dorsal skin of the middle finger and the palmar skin of the index finger to form a skin pedicle, and then, immobility of the two fingers was maintained to prevent avulsion. The index tip obtained good blood supply and survived completely (Figure 3). Detachment of the index and middle finger was performed after 3 weeks, and both of the fingers showed good

  5. KIAI: FIGUR ELITE PESANTREN

    Directory of Open Access Journals (Sweden)

    Mohammad Takdir Ilahi

    2015-10-01

    Full Text Available In a pesantren (Islamic boarding school, kiai is an strategic element. Javanese kiai mainly believe that a pesantren is a small palace where he becomes the ultimate source of power and authority. Even though he lives in a rural village, he becomes a member of elite group in social, politic and economic sides in the society. Kiai who leads big pesantren has successfully enlarged their power in term of nation so kiai could be accepted in national elite. The position of kiai is higher among all pesantren elements. The degree as an Islamic scholar is exactly a sacred degree in pesantren culture and tradition. Without his figure, it is impossible for a pesantren to develop and survive. Kiai holds an ultimate position on educate the behavior and morality of the santri (students to be qualified and compatible Muslims generation. Kiai is not only a leader but he is also the man behind the leadership itself in supporting the progress of Islamic education institution for Muslims generations.

  6. Sirenomelia with radial dysplasia.

    Science.gov (United States)

    Kulkarni, M L; Abdul Manaf, K M; Prasannakumar, D G; Kulkarni, Preethi M

    2004-05-01

    Sirenomelia is a rare anomaly usually associated with other multiple malformations. In this communication the authors report a case of sirenomelia associated with multiple malformations, which include radial hypoplasia also. Though several theories have been proposed regarding the etiology of multiple malformation syndromes in the past, the recent theory of primary developmental defect during blastogenesis holds good in this case.

  7. Radially truncated galactic discs

    NARCIS (Netherlands)

    Grijs, R. de; Kregel, M.; Wesson, K H

    2000-01-01

    Abstract: We present the first results of a systematic analysis of radially truncatedexponential discs for four galaxies of a sample of disc-dominated edge-onspiral galaxies. Edge-on galaxies are very useful for the study of truncatedgalactic discs, since we can follow their light distributions out

  8. The artery blood supply variant of the upper limb

    Science.gov (United States)

    MASLARSKI, IVAN

    2015-01-01

    Variations of arterial patterns in the upper limb have represented the most common subject of vascular anatomy. Different types of artery branching pattern of the upper limb are very important for orthopedists in angiographic and microvascular surgical practice. The brachial artery (BA) is the most important vessel in the normal vascular anatomy of the upper limb. The classical pattern of the palmar hand region distribution shows the superficial palmar arch. Normally this arch is formed by the superficial branch of the ulnar artery and completed on the lateral side by one of these arteries: the superficial palmar branch of the radial artery, the princeps pollicis artery, the superficial palmar branch of the radial artery or the median artery. After the routine dissection of the right upper limb of an adult male cadaver, we found a very rare variant of the superficial arch artery – a division in a higher level brachial artery. We found this division at 10.4 cm from the beginning of the brachial artery. This superficial brachial artery became a radial artery and was not involved in the formation of the palm arch. In the forearm region, the artery variant was present with the median artery and the ulnar artery, which form the superficial palm arch. PMID:26733754

  9. Unintentional arterial puncture during cephalic vein cannulation: case report and anatomical study

    NARCIS (Netherlands)

    Lirk, P.; Keller, C.; Colvin, J.; Colvin, H.; Rieder, J.; Maurer, H.; Moriggl, B.

    2004-01-01

    The cephalic antebrachial vein is often used for venous access. However, superficial radial arteries of the forearm are known and unintentional arterial puncture can result from attempts to cannulate the lateral veins of the arm. Accidental puncture of a superficial radial artery during peripheral

  10. Variable stator radial turbine

    Science.gov (United States)

    Rogo, C.; Hajek, T.; Chen, A. G.

    1984-01-01

    A radial turbine stage with a variable area nozzle was investigated. A high work capacity turbine design with a known high performance base was modified to accept a fixed vane stagger angle moveable sidewall nozzle. The nozzle area was varied by moving the forward and rearward sidewalls. Diffusing and accelerating rotor inlet ramps were evaluated in combinations with hub and shroud rotor exit rings. Performance of contoured sidewalls and the location of the sidewall split line with respect to the rotor inlet was compared to the baseline. Performance and rotor exit survey data are presented for 31 different geometries. Detail survey data at the nozzle exit are given in contour plot format for five configurations. A data base is provided for a variable geometry concept that is a viable alternative to the more common pivoted vane variable geometry radial turbine.

  11. Estimation of Radial Runout

    OpenAIRE

    Nilsson, Martin

    2007-01-01

    The demands for ride comfort quality in today's long haulage trucks are constantly growing. A part of the ride comfort problems are represented by internal vibrations caused by rotating mechanical parts. This thesis work focus on the vibrations generated from radial runout on the wheels. These long haulage trucks travel long distances on smooth highways, with a constant speed of 90 km/h resulting in a 7 Hz oscillation. This frequency creates vibrations in the cab, which can be found annoying....

  12. Radial Fuzzy Systems

    Czech Academy of Sciences Publication Activity Database

    Coufal, David

    2017-01-01

    Roč. 319, 15 July (2017), s. 1-27 ISSN 0165-0114 R&D Projects: GA MŠk(CZ) LD13002 Institutional support: RVO:67985807 Keywords : fuzzy systems * radial functions * coherence Subject RIV: BA - General Mathematics OBOR OECD: Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8) Impact factor: 2.718, year: 2016

  13. Radial Field Piezoelectric Diaphragms

    Science.gov (United States)

    Bryant, R. G.; Effinger, R. T., IV; Copeland, B. M., Jr.

    2002-01-01

    A series of active piezoelectric diaphragms were fabricated and patterned with several geometrically defined Inter-Circulating Electrodes "ICE" and Interdigitated Ring Electrodes "ICE". When a voltage potential is applied to the electrodes, the result is a radially distributed electric field that mechanically strains the piezoceramic along the Z-axis (perpendicular to the applied electric field). Unlike other piezoelectric bender actuators, these Radial Field Diaphragms (RFDs) strain concentrically yet afford high displacements (several times that of the equivalent Unimorph) while maintaining a constant circumference. One of the more intriguing aspects is that the radial strain field reverses itself along the radius of the RFD while the tangential strain remains relatively constant. The result is a Z-deflection that has a conical profile. This paper covers the fabrication and characterization of the 5 cm. (2 in.) diaphragms as a function of poling field strength, ceramic thickness, electrode type and line spacing, as well as the surface topography, the resulting strain field and displacement as a function of applied voltage at low frequencies. The unique features of these RFDs include the ability to be clamped about their perimeter with little or no change in displacement, the environmentally insulated packaging, and a highly repeatable fabrication process that uses commodity materials.

  14. Perceived radial translation during centrifugation

    NARCIS (Netherlands)

    Bos, J.E.; Correia Grácio, B.J.

    2015-01-01

    BACKGROUND: Linear acceleration generally gives rise to translation perception. Centripetal acceleration during centrifugation, however, has never been reported giving rise to a radial, inward translation perception. OBJECTIVE: To study whether centrifugation can induce a radial translation

  15. Facts and figures in 2004

    International Nuclear Information System (INIS)

    Lavergne, R.; Meuric, L.; Scherrer, S.; Paquel, V.; Louati, S.; Thienard, H.

    2005-01-01

    This document gathers a series of articles dedicated to the situation of the energy sector in France at the end of 2004: -) the energy balance sheet, -) the trend concerning energy consumption since 1973, -) the energy bill, -) figures about electrical power, -) figures about natural gas, -) figures about solid fossil fuels, -) figures about oil, and -) figures about renewable energies. The important fact to note is that the energy bill has soared by 24.1% to reach 28.35 milliard euros which represents 1.75% of the gross national product (PIB). The evolution over the year 2004 of the factors that contribute to the level of the energy bill is: - the import-export energy quantity differential: +7.5%, - the import-export energy cost differential (in Usa dollar): +27.1%, and - the fall of the dollar: -9.1%. (A.C.)

  16. Arterial responses during migraine headache

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Olesen, J

    1990-01-01

    The superficial temporal artery has been thought to be the main focus of pain during migraine attacks, but its diameter has never been measured directly. The use of a new, high-resolution ultrasound machine to measure arterial size in 25 migraine patients with unilateral head pain showed...... that the lumen was wider on the painful than on the non-painful side during a migraine attack. The diameters of both radial arteries and the temporal artery on the non-painful side were smaller during than between attacks. The generalised vasoconstriction was not shared by the temporal artery on the affected...... side, which suggests a local vasodilatory response. The findings suggest that cephalic arteries may play a role in migraine pathogenesis....

  17. Evaluation of the pole figure

    International Nuclear Information System (INIS)

    Cabrera B, E.; Macias B, L.R.

    1984-01-01

    In the present work it's shown the possibility of obtaining a pole-figure from the data generated in a conventional X-ray equipment, with a commercial goniometer and no electronic device to process the data. The way to plot the pole-figure on-line is by means of measuring the diffractogram and plot manually the stereographic projections. The atainable precision is very low in such a cumbersome process. In this paper we substitute such method by storing the data in a punched tape from a conventional teletype. The data is processed in a computer and the pole-figure is recorded by a plotter attached to the computer. (author)

  18. Radial reflection diffraction tomography

    Science.gov (United States)

    Lehman, Sean K.

    2012-12-18

    A wave-based tomographic imaging method and apparatus based upon one or more rotating radially outward oriented transmitting and receiving elements have been developed for non-destructive evaluation. At successive angular locations at a fixed radius, a predetermined transmitting element can launch a primary field and one or more predetermined receiving elements can collect the backscattered field in a "pitch/catch" operation. A Hilbert space inverse wave (HSIW) algorithm can construct images of the received scattered energy waves using operating modes chosen for a particular application. Applications include, improved intravascular imaging, bore hole tomography, and non-destructive evaluation (NDE) of parts having existing access holes.

  19. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... 2018 Alzheimer's Disease Facts and Figures report contains data on the impact of this disease in every ... with third parties. Please read our security and privacy policy . Plan ahead Get help and support I ...

  20. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... Home Text size: A A A 2018 Alzheimer's Disease Facts and Figures Download the full report: Download ... about memory loss? KNOW THE 10 SIGNS Alzheimer's Disease Facts in Each State The 2018 Alzheimer's Disease ...

  1. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... Join the Cause alz.org >> Alzheimer's & Dementia >> Home Text size: A A A 2018 Alzheimer's Disease Facts and Figures Download the full report: Download the Infographic: English Spanish Share the ...

  2. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... Dementia >> Home Text size: A A A 2018 Alzheimer's Disease Facts and Figures Download the full report: Download ... worried about memory loss? KNOW THE 10 SIGNS Alzheimer's Disease Facts in Each State The 2018 Alzheimer's Disease ...

  3. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... home care. Take action. Become an advocate SPECIAL REPORT: FINANCIAL AND PERSONAL BENEFITS OF EARLY DIAGNOSIS Early ... State The 2018 Alzheimer's Disease Facts and Figures report contains data on the impact of this disease ...

  4. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... THE 10 SIGNS Alzheimer's Disease Facts in Each State The 2018 Alzheimer's Disease Facts and Figures report ... on the impact of this disease in every state across the nation. Click below to see the ...

  5. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... 272.3900 Donate Alzheimer's & Dementia What Is Alzheimer's? Brain Tour Younger/Early Onset Risk Factors Genetics Myths ... Dementia Korsakoff Syndrome Related Conditions CTE MCI Traumatic Brain Injury Facts and Figures Know the 10 Signs ...

  6. Alzheimer's Disease Facts and Figures

    Science.gov (United States)

    ... Dementia >> Home Text size: A A A 2018 Alzheimer's Disease Facts and Figures Download the full report: ... twice as high. Invest in a world without Alzheimer's. Donate Caregivers Eighty-three percent of the help ...

  7. Alzheimer's Disease Facts and Figures

    Medline Plus

    Full Text Available ... Dementia >> Home Text size: A A A 2018 Alzheimer's Disease Facts and Figures Download the full report: ... twice as high. Invest in a world without Alzheimer's. Donate Caregivers Eighty-three percent of the help ...

  8. Retorical figures in advertising language

    OpenAIRE

    Radenković-Šošić Bojana

    2012-01-01

    Promotional activities are very often based on advertising and diverse types of public relations. In order to attract consumers' attention and achieve communication goals set by the corporate strategy, advertisers frequently use rhetorical elements in advertising discourse. The advertisers try to convey a desired message and to communicate with the recipient of the message by using various rhetorical figures. It is argued that understanding the structure and function of rhetorical figur...

  9. Radial semiconductor drift chambers

    International Nuclear Information System (INIS)

    Rawlings, K.J.

    1987-01-01

    The conditions under which the energy resolution of a radial semiconductor drift chamber based detector system becomes dominated by the step noise from the detector dark current have been investigated. To minimise the drift chamber dark current attention should be paid to carrier generation at Si/SiO 2 interfaces. This consideration conflicts with the desire to reduce the signal risetime: a higher drift field for shorter signal pulses requires a larger area of SiO 2 . Calculations for the single shaping and pseudo Gaussian passive filters indicate that for the same degree of signal risetime sensitivity in a system dominated by the step noise from the detector dark current, the pseudo Gaussian filter gives only a 3% improvement in signal/noise and 12% improvement in rate capability compared with the single shaper performance. (orig.)

  10. ISR Radial Field Magnet

    CERN Multimedia

    1983-01-01

    There were 37 (normal) + 3 (special) Radial Field magnets in the ISR to adjust vertically the closed orbit. Gap heights and strengths were 200 mm and .12 Tm in the normal magnets, 220 mm and .18 Tm in the special ones. The core length was 430 mm in both types. Due to their small length as compared to the gap heights the end fringe field errors were very important and had to be compensated by suitably shaping the poles. In order to save on cables, as these magnets were located very far from their power supplies, the coils of the normal type magnets were formed by many turns of solid cpper conductor with some interleaved layers of hollow conductor directly cooled by circulating water

  11. The ARCS radial collimator

    International Nuclear Information System (INIS)

    Stone, M.B.; Abernathy, D.L.; Niedziela, J.L.; Overbay, M.A.

    2015-01-01

    We have designed, installed, and commissioned a scattered beam radial collimator for use at the ARCS Wide Angular Range Chopper Spectrometer at the Spallation Neutron Source. The collimator has been designed to work effectively for thermal and epithermal neutrons and with a range of sample environments. Other design considerations include the accommodation of working within a high vacuum environment and having the ability to quickly install and remove the collimator from the scattered beam. The collimator is composed of collimating blades (or septa). The septa are 12 micron thick Kapton foils coated on each side with 39 microns of enriched boron carbide ( 10 B 4 C with 10 B > 96%) in an ultra-high vacuum compatible binder. The collimator blades represent an additional 22 m 2 of surface area. In the article we present collimator's design and performance and methodologies for its effective use

  12. Antiproton compression and radial measurements

    CERN Document Server

    Andresen, G B; Bowe, P D; Bray, C C; Butler, E; Cesar, C L; Chapman, S; Charlton, M; Fajans, J; Fujiwara, M C; Funakoshi, R; Gill, D R; Hangst, J S; Hardy, W N; Hayano, R S; Hayden, M E; Humphries, A J; Hydomako, R; Jenkins, M J; Jorgensen, L V; Kurchaninov, L; Lambo, R; Madsen, N; Nolan, P; Olchanski, K; Olin, A; Page R D; Povilus, A; Pusa, P; Robicheaux, F; Sarid, E; Seif El Nasr, S; Silveira, D M; Storey, J W; Thompson, R I; Van der Werf, D P; Wurtele, J S; Yamazaki, Y

    2008-01-01

    Control of the radial profile of trapped antiproton clouds is critical to trapping antihydrogen. We report detailed measurements of the radial manipulation of antiproton clouds, including areal density compressions by factors as large as ten, achieved by manipulating spatially overlapped electron plasmas. We show detailed measurements of the near-axis antiproton radial profile, and its relation to that of the electron plasma. We also measure the outer radial profile by ejecting antiprotons to the trap wall using an octupole magnet.

  13. Forskerklummen: Figured Worlds of literacy

    DEFF Research Database (Denmark)

    Møller, Hanne

    2017-01-01

    Figured worlds”, altså forestillede verdener, er et teoretisk begreb, som i øjeblikket dukker op i flere og flere forskningssammenhænge. Det bliver anvendt på mange forskellige måder både inden for uddannelsesforskning og i forskning i literacy.......”Figured worlds”, altså forestillede verdener, er et teoretisk begreb, som i øjeblikket dukker op i flere og flere forskningssammenhænge. Det bliver anvendt på mange forskellige måder både inden for uddannelsesforskning og i forskning i literacy....

  14. Radial expansion and multifragmentation

    International Nuclear Information System (INIS)

    Angelique, J.C.; Bizard, G.; Bougault, R.; Brou, R.; Buta, A.; Colin, J.; Cussol, D.; Durand, D.; Kerambrun, A.; Le Brun, C.; Lecolley, J.F.; Lopez, O.; Louvel, M.; Meslin, C.; Nakagawa, T.; Patry, J.P.; Peter, J.; Popescu, R.; Regimbart, R.; Steckmeyer, J.C.; Tamain, B.; Vient, E.; Yuasa-Nakagawa, K.; Wieloch, A.

    1998-01-01

    The light systems 36 Ar + 27 Al and 64 Zn + nat Ti were measured at several bombarding energies between ∼ 35 and 95 MeV/nucleon. It was found that the predominant part of the cross section is due to binary collisions. In this paper the focus is placed on the properties of the quasi-projectile nuclei. In the central collisions the excitation energies of the quasi-projectile reach values exceeding largely 10 MeV/nucleon. The slope of the high energy part of the distribution can give only an upper limit of the apparent temperature (the average temperature along the decay chain). The highly excited quasi-projectile may get rapidly fragmented rather than sequentially. The heavy fragments are excited and can emit light particles (n, p, d, t, 3 He, α,...) what perturbs additionally the spectrum of these particles. Concerning the expansion energy, one can determine the average kinetic energies of the product (in the quasi-projectile-framework) and compare with simulation values. To fit the experimental data an additional radial expansion energy is to be considered. The average expansion energy depends slightly on the impact parameter but it increases with E * / A, ranging from 0.4 to 1,2 MeV/nucleon for an excitation energy increasing from 7 to 10.5 MeV/nucleon. This collective radial energy seems to be independent of the fragment mass, what is possibly valid for the case of larger quasi-projectile masses. The origin of the expansion is to be determined. It may be due to a compression in the interaction zone at the initial stage of the collision, which propagates in the quasi-projectile and quasi-target, or else, may be due, simply, to the increase of thermal energy leading to a rapid fragment emission. The sequential de-excitation calculation overestimates light particle emission and consequently heavy residues, particularly, at higher excitation energies. This disagreement indicates that a sequential process can not account for the di-excitation of very hot nuclei

  15. Radial particle distributions in PARMILA simulation beams

    International Nuclear Information System (INIS)

    Boicourt, G.P.

    1984-03-01

    The estimation of beam spill in particle accelerators is becoming of greater importance as higher current designs are being funded. To the present, no numerical method for predicting beam-spill has been available. In this paper, we present an approach to the loss-estimation problem that uses probability distributions fitted to particle-simulation beams. The properties of the PARMILA code's radial particle distribution are discussed, and a broad class of probability distributions are examined to check their ability to fit it. The possibility that the PARMILA distribution is a mixture is discussed, and a fitting distribution consisting of a mixture of two generalized gamma distributions is found. An efficient algorithm to accomplish the fit is presented. Examples of the relative prediction of beam spill are given. 26 references, 18 figures, 1 table

  16. Radial gas turbine design

    Energy Technology Data Exchange (ETDEWEB)

    Krausche, S.; Ohlsson, Johan

    1998-04-01

    The objective of this work was to develop a program dealing with design point calculations of radial turbine machinery, including both compressor and turbine, with as few input data as possible. Some simple stress calculations and turbine metal blade temperatures were also included. This program was then implanted in a German thermodynamics program, Gasturb, a program calculating design and off-design performance of gas turbines. The calculations proceed with a lot of assumptions, necessary to finish the task, concerning pressure losses, velocity distribution, blockage, etc., and have been correlated with empirical data from VAT. Most of these values could have been input data, but to prevent the user of the program from drowning in input values, they are set as default values in the program code. The output data consist of geometry, Mach numbers, predicted component efficiency etc., and a number of graphical plots of geometry and velocity triangles. For the cases examined, the error in predicted efficiency level was within {+-} 1-2% points, and quite satisfactory errors in geometrical and thermodynamic conditions were obtained Examination paper. 18 refs, 36 figs

  17. Radial flow heat exchanger

    Science.gov (United States)

    Valenzuela, Javier

    2001-01-01

    A radial flow heat exchanger (20) having a plurality of first passages (24) for transporting a first fluid (25) and a plurality of second passages (26) for transporting a second fluid (27). The first and second passages are arranged in stacked, alternating relationship, are separated from one another by relatively thin plates (30) and (32), and surround a central axis (22). The thickness of the first and second passages are selected so that the first and second fluids, respectively, are transported with laminar flow through the passages. To enhance thermal energy transfer between first and second passages, the latter are arranged so each first passage is in thermal communication with an associated second passage along substantially its entire length, and vice versa with respect to the second passages. The heat exchangers may be stacked to achieve a modular heat exchange assembly (300). Certain heat exchangers in the assembly may be designed slightly differently than other heat exchangers to address changes in fluid properties during transport through the heat exchanger, so as to enhance overall thermal effectiveness of the assembly.

  18. Choreography Styles in Figure Skating

    Science.gov (United States)

    Moormann, Peter Paul

    2006-01-01

    Fifty-eight figure skating trainers from fifteen different countries acted as volunteers in this study on choreography styles. The styles were based on reports of artistic-creative strategies in composing music, drawing, writing poems or novels, and in making dances. The prevalence of the Mozartian (at the onset the choreographer already has a…

  19. Human Figure Drawings in Perspective.

    Science.gov (United States)

    Naglieri, Jack A.

    1993-01-01

    Responds to previous article (Motta, Little, and Tobin, this issue) which reviewed data-based studies on figure drawings and found little support for their validity or use in assessing personality, behavior, emotion, or intellectual functioning. Contends that article is unacceptable for publication in present form, with main criticism being that…

  20. Stability of radial swirl flows

    International Nuclear Information System (INIS)

    Dou, H S; Khoo, B C

    2012-01-01

    The energy gradient theory is used to examine the stability of radial swirl flows. It is found that the flow of free vortex is always stable, while the introduction of a radial flow will induce the flow to be unstable. It is also shown that the pure radial flow is stable. Thus, there is a flow angle between the pure circumferential flow and the pure radial flow at which the flow is most unstable. It is demonstrated that the magnitude of this flow angle is related to the Re number based on the radial flow rate, and it is near the pure circumferential flow. The result obtained in this study is useful for the design of vaneless diffusers of centrifugal compressors and pumps as well as other industrial devices.

  1. Retorical figures in advertising language

    Directory of Open Access Journals (Sweden)

    Radenković-Šošić Bojana

    2012-01-01

    Full Text Available Promotional activities are very often based on advertising and diverse types of public relations. In order to attract consumers' attention and achieve communication goals set by the corporate strategy, advertisers frequently use rhetorical elements in advertising discourse. The advertisers try to convey a desired message and to communicate with the recipient of the message by using various rhetorical figures. It is argued that understanding the structure and function of rhetorical figures in advertising requires a "text- and reader-aware approach". The use of rhetorical figures in advertising has been overlooked in consumer research. This paper shows that the use of rhetorical elements in the advertising discourse is very frequent, but at the same time it is questioned if the function of the rhetorical figures is just a communication with the target market (which is a base of communication models and if the consequences of linguistic influences are much more serious. The complex nature of advertising language with various rhetorical figures (thropes and schemes do not just stimulate recipients to demonstrate a desirable behavior, but indirectly it constructs a concept of desirable lifestyle and it induces them to identify themselves with the explained model. Moreover, the analyzed corpus included advertising slogans of social responsible companies as well as advertising campaigns with elements of diverse ideologies. In the time of digitization and a rapid information flow, consumer's attention is less dedicated to the advertising messages. Therefore, it should be expected that in the future advertisers will have to adjust linguistic, audio and visual techniques to the unfocused message recipients.

  2. Thrombosis of digital arteries associated with tamoxifen use: case report.

    Science.gov (United States)

    Hutchison, Richard L; Rayan, Ghazi M

    2012-02-01

    Arterial thrombosis in the upper extremity occurs often at the wrist. We report a unique case of thrombosis that involved multiple digital arteries, without radial or ulnar artery involvement, which developed only after using tamoxifen despite chronic occupational blunt percussive hand use. Revascularization was achieved after thrombectomy. Multiple digital arterial thromboses may complicate the use of tamoxifen. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  3. Arterial endothelial function measurement method and apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Maltz, Jonathan S; Budinger, Thomas F

    2014-03-04

    A "relaxoscope" (100) detects the degree of arterial endothelial function. Impairment of arterial endothelial function is an early event in atherosclerosis and correlates with the major risk factors for cardiovascular disease. An artery (115), such as the brachial artery (BA) is measured for diameter before and after several minutes of either vasoconstriction or vasorelaxation. The change in arterial diameter is a measure of flow-mediated vasomodification (FMVM). The relaxoscope induces an artificial pulse (128) at a superficial radial artery (115) via a linear actuator (120). An ultrasonic Doppler stethoscope (130) detects this pulse 10-20 cm proximal to the point of pulse induction (125). The delay between pulse application and detection provides the pulse transit time (PTT). By measuring PTT before (160) and after arterial diameter change (170), FMVM may be measured based on the changes in PTT caused by changes in vessel caliber, smooth muscle tone and wall thickness.

  4. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction

    NARCIS (Netherlands)

    Hekner, D.D.; Roeling, TAP; van Cann, EM

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were

  5. Radial forearm free flap morbidity: A rare case of a normal preoperative arteriogram and acute intraoperative hand ischemia

    OpenAIRE

    Bruner, Terrence W; Hanasono, Matthew M; Skoracki, Roman J

    2011-01-01

    The radial forearm free flap is ideal for reconstructive microsurgery due to its thin, pliable fasciocutaneous tissue, reliable anatomy and ease and simplicity of flap elevation. However, one of the major complications is hand ischemia due to sacrifice of the radial artery, although it is a rare occurrence. A case involving a 73-year-old man who developed intraoperative hand ischemia after elevation of a radial forearm free flap is presented.

  6. Third quarter 2005 sales figures

    International Nuclear Information System (INIS)

    2005-01-01

    With manufacturing facilities in over 40 countries and a sales network in over 100, AREVA offers customers technological solutions for nuclear power generation and electricity transmission and distribution. The group also provides interconnect systems to the telecommunications, computer and automotive markets. This document presents the sales figures of the group for the third quarter of 2005: sales revenues in the front end division, in the reactor and services division, in the back end division and in the transmission and distribution division

  7. Radial retinotomy in the macula.

    Science.gov (United States)

    Bovino, J A; Marcus, D F

    1984-01-01

    Radial retinotomy is an operative procedure usually performed in the peripheral or equatorial retina. To facilitate retinal attachment, the authors used intraocular scissors to perform radial retinotomy in the macula of two patients during vitrectomy surgery. In the first patient, a retinal detachment complicated by periretinal proliferation and macula hole formation was successfully reoperated with the aid of three radial cuts in the retina at the edges of the macular hole. In the second patient, an intraoperative retinal tear in the macula during diabetic vitrectomy was also successfully repaired with the aid of radial retinotomy. In both patients, retinotomy in the macula was required because epiretinal membranes, which could not be easily delaminated, were hindering retinal reattachment.

  8. Detonation in supersonic radial outflow

    KAUST Repository

    Kasimov, Aslan R.; Korneev, Svyatoslav

    2014-01-01

    We report on the structure and dynamics of gaseous detonation stabilized in a supersonic flow emanating radially from a central source. The steady-state solutions are computed and their range of existence is investigated. Two-dimensional simulations

  9. The effect of nitric oxide synthase inhibition on histamine induced headache and arterial dilatation in migraineurs

    DEFF Research Database (Denmark)

    Lassen, L H; Christiansen, I; Iversen, Helle Klingenberg

    2003-01-01

    -decrease in MCA blood velocity, or dilatation of neither the temporal nor the radial artery. L-NMMA constricted the temporal artery by 8% before histamine infusion, whereas the radial artery was unaffected. The temporal artery dilated 4-5 times more than the radial artery during histamine infusion. In conclusion...... the use of a NOS inhibitor in the highest possible dose did not block the histamine-induced headache response or arterial dilatation. Either the concentration of L-NMMA reaching the smooth muscle cell was insufficient or, histamine dilates arteries and causes headache via NO independent mechanisms. Our...... results showed for the first time a craniospecificity for the vasodilating effect of histamine and for the arterial effects of NOS inhibition....

  10. The Figure in the Idiom

    OpenAIRE

    JONES, Willie

    1996-01-01

    The argument: every metaphor and metaphoric idiom grows out of and is nourished by a seminal metonymy. Since these germinating seeds-and the mineral elements which feed them-work under cover, we tend to overlook them when we feast off harvests cropped from the fields of metaphor: and we therefore forget to take into account the radical fecundity of the metonymic germ. This essay attempts to remedy such forgetfulness. At the same time, it also claims that metonymy (a figure of rhetoric) and im...

  11. Les figures multiples du maire.

    Directory of Open Access Journals (Sweden)

    Olivier Lebraud

    2004-06-01

    Full Text Available Alors même que l’ensemble du personnel gouvernemental et parlementaire est sujet à une relative désaffection de la part des citoyens, les maires français jouissent, on le sait, d’une popularité qui fait d’eux les figures centrales de la scène politique. Au-delà de la décentralisation, qui a souvent renforcé leur image de décideurs, ils ont su tirer parti de la dimension identitaire qui caractérise l’échelon communal pour devenir les acteurs indispensables de la vie locale. ...

  12. Measurement of Blood Flow in an Intracranial Artery Bypass From the Internal Maxillary Artery by Intraoperative Duplex Sonography.

    Science.gov (United States)

    Yu, Zaitao; Shi, Xiang'en; Brohi, Shams Raza; Qian, Hai; Liu, Fangjun; Yang, Yang

    2017-02-01

    This study explored the hemodynamic characteristics of a subcranial-intracranial bypass from the internal maxillary artery by measuring blood flow on intraoperative duplex sonography. The hemodynamic parameters of the internal maxillary artery (n = 20), radial artery (n = 20), internal maxillary artery-middle cerebral artery bypass (n = 42), and internal maxillary artery-posterior cerebral artery bypass (n = 9) were measured by intraoperative duplex sonography. There was no significant difference in the internal diameters of the internal maxillary and radial arteries (mean ± SD, 2.51 ± 0.34 versus 2.56 ± 0.22 mm; P = .648). The mean radial artery graft length for subcranial-intracranial bypasses was 88.5 ± 12.78 mm (95% confidence interval [CI], 80.8-90.2 mm). Internal maxillary artery-middle cerebral artery bypasses required a shorter radial artery graft than internal maxillary artery-posterior cerebral artery bypasses (77.8 ± 2.47 versus 104.8 ± 4.77 mm; P = .001). The mean flow volumes were 85.3 ± 18.5 mL/min (95% CI, 76.6-93.9 mL/min) for the internal maxillary artery, 72.6 ± 26.4 mL/min (95% CI, 64.3-80.9 mL/min) for internal maxillary artery-middle cerebral artery bypasses, and 45.4 ± 6.7 mL/min (95% CI, 40.7-50.0 mL/min) for internal maxillary artery-posterior cerebral artery bypasses. All grafts were opened after the success of the salvage procedures had been established, and the early patency rates (1 month after the operation) were 95% for internal maxillary artery-middle cerebral artery bypasses and 100% the internal maxillary artery-posterior cerebral artery bypasses. Measurement of blood flow by intraoperative sonography can be helpful in decision making and predicting graft patency and success after neurosurgical bypass procedures. © 2016 by the American Institute of Ultrasound in Medicine.

  13. Hooke's figurations: a figural drawing attributed to Robert Hooke.

    Science.gov (United States)

    Hunter, Matthew C

    2010-09-20

    The experimental philosopher Robert Hooke (1635-1703) is known to have apprenticed to the leading painter Peter Lely on his first arrival in London in the late 1640s. Yet the relevance of Hooke's artistic training to his mature draughtsmanship and identity has remained unclear. Shedding light on that larger interpretive problem, this article argues for the attribution to Hooke of a figural drawing now in Tate Britain (T10678). This attributed drawing is especially interesting because it depicts human subjects and bears Hooke's name functioning as an artistic signature, both highly unusual features for his draughtsmanship. From evidence of how this drawing was collected and physically placed alongside images by leading artists in the early eighteenth century, I suggest how it can offer new insight into the reception of Hooke and his graphic work in the early Enlightenment.

  14. Brachiomedian artery (arteria brachiomediana revisited: a comprehensive review

    Directory of Open Access Journals (Sweden)

    David Kachlik

    2016-03-01

    Full Text Available This article reviews in detail the superficial brachiomedian artery (arteria brachiomediana superficialis, a very rare variant of the main arterial trunks of the upper limb. It branches either from the axillary artery or the brachial artery, descends superficially in the arm (similar to the course of the superficial brachial artery and continues across the cubital fossa, runs superficially in the forearm, approaches the median nerve and enters the carpal canal to reach the hand. It usually terminates in the superficial palmar arch. The first drawing was published, in 1830, and the first description was published, in 1844. Altogether, to our knowledge, only 31 cases of a true, superficial brachiomedian artery have been reported (Some cases are incorrectly reported as superficial brachioradiomedian artery or superficial brachioulnomedian artery. Based on a meta-analysis of known, available studies, the incidence is 0.23% in Caucasians and 1.48% in Mongolians. Knowing whether or not this arterial variant is present is important in clinical medicine and relevant for: The catheterization via the radial or ulnar artery; harvesting the vascular pedicle for a forearm flap based on the radial, ulnar or superficial brachiomedian arteries; the possible collateral circulation in cases of the arterial closure; and the surgical management of carpal tunnel syndrome. Its presence can elevate the danger of an injury to the superficially located variant artery or of an accidental injection.

  15. Enhanced spatial resolution on figures versus grounds.

    Science.gov (United States)

    Hecht, Lauren N; Cosman, Joshua D; Vecera, Shaun P

    2016-07-01

    Much is known about the cues that determine figure-ground assignment, but less is known about the consequences of figure-ground assignment on later visual processing. Previous work has demonstrated that regions assigned figural status are subjectively more shape-like and salient than background regions. The increase in subjective salience of figural regions could be caused by a number of processes, one of which may be enhanced perceptual processing (e.g., an enhanced neural representation) of figures relative to grounds. We explored this hypothesis by having observers perform a perceptually demanding spatial resolution task in which targets appeared on either figure or ground regions. To rule out a purely attentional account of figural salience, observers discriminated targets on the basis of a region's color (red or green), which was equally likely to define the figure or the ground. The results of our experiments showed that targets appearing on figures were discriminated more accurately than those appearing in ground regions. In addition, targets appearing on figures were discriminated better than those presented in regions considered figurally neutral, but targets appearing within ground regions were discriminated more poorly than those appearing in figurally neutral regions. Taken together, our findings suggest that when two regions share a contour, regions assigned as figure are perceptually enhanced, whereas regions assigned as ground are perceptually suppressed.

  16. Enhanced spatial resolution on figures versus grounds

    Science.gov (United States)

    Hecht, Lauren N.; Cosman, Joshua D.; Vecera, Shaun P.

    2016-01-01

    Much is known about the cues that determine figure-ground assignment, but less is known about the consequences of figure-ground assignment on later visual processing. Previous work has demonstrated that regions assigned figural status are subjectively more shape-like and salient than background regions. The increase in subjective salience of figural regions could be caused by a number of processes, one of which may be enhanced perceptual processing (e.g., an enhanced neural representation) of figures relative to grounds. We explored this hypothesis by having observers perform a perceptually demanding spatial resolution task in which targets appeared either on figure or ground regions. To rule out a purely attentional account of figural salience, observers discriminated targets on the basis of a region’s color (red or green), which was equally likely to define the figure or the ground. The results of our experiments show that targets appearing on figures were discriminated more accurately than those appearing in ground regions. In addition, targets appearing on figures were discriminated better than those presented in regions considered figurally neutral, but targets appearing within ground regions were discriminated more poorly than those appearing in figurally neutral regions. Taken together, our findings suggest that when two regions share a contour, regions assigned as figure are perceptually enhanced, whereas regions assigned as grounds are perceptually suppressed. PMID:27048441

  17. Radial lean direct injection burner

    Science.gov (United States)

    Khan, Abdul Rafey; Kraemer, Gilbert Otto; Stevenson, Christian Xavier

    2012-09-04

    A burner for use in a gas turbine engine includes a burner tube having an inlet end and an outlet end; a plurality of air passages extending axially in the burner tube configured to convey air flows from the inlet end to the outlet end; a plurality of fuel passages extending axially along the burner tube and spaced around the plurality of air passage configured to convey fuel from the inlet end to the outlet end; and a radial air swirler provided at the outlet end configured to direct the air flows radially toward the outlet end and impart swirl to the air flows. The radial air swirler includes a plurality of vanes to direct and swirl the air flows and an end plate. The end plate includes a plurality of fuel injection holes to inject the fuel radially into the swirling air flows. A method of mixing air and fuel in a burner of a gas turbine is also provided. The burner includes a burner tube including an inlet end, an outlet end, a plurality of axial air passages, and a plurality of axial fuel passages. The method includes introducing an air flow into the air passages at the inlet end; introducing a fuel into fuel passages; swirling the air flow at the outlet end; and radially injecting the fuel into the swirling air flow.

  18. Radial-Electric-Field Piezoelectric Diaphragm Pumps

    Science.gov (United States)

    Bryant, Robert G.; Working, Dennis C.; Mossi, Karla; Castro, Nicholas D.; Mane, Pooma

    2009-01-01

    In a recently invented class of piezoelectric diaphragm pumps, the electrode patterns on the piezoelectric diaphragms are configured so that the electric fields in the diaphragms have symmetrical radial (along-the-surface) components in addition to through-the-thickness components. Previously, it was accepted in the piezoelectric-transducer art that in order to produce the out-of-plane bending displacement of a diaphragm needed for pumping, one must make the electric field asymmetrical through the thickness, typically by means of electrodes placed on only one side of the piezoelectric material. In the present invention, electrodes are placed on both sides and patterned so as to produce substantial radial as well as through-the-thickness components. Moreover, unlike in the prior art, the electric field can be symmetrical through the thickness. Tests have shown in a given diaphragm that an electrode configuration according to this invention produces more displacement than does a conventional one-sided electrode pattern. The invention admits of numerous variations characterized by various degrees of complexity. Figure 1 is a simplified depiction of a basic version. As in other piezoelectric diaphragm pumps of similar basic design, the prime mover is a piezoelectric diaphragm. Application of a suitable voltage to the electrodes on the diaphragm causes it to undergo out-of-plane bending. The bending displacement pushes a fluid out of, or pulls the fluid into, a chamber bounded partly by the diaphragm. Also as in other diaphragm pumps in general, check valves ensure that the fluid flows only in through one port and only out through another port.

  19. Michigan transportation facts & figures : public transportation

    Science.gov (United States)

    2002-08-16

    This on-line document is part of a series, Transportation Facts & Figures, by the Michigan Department of Transportation (MDOT). The Public Transit section of Transportation Facts & Figures cover such topics as intercity bus service, intercity rail se...

  20. Self-consistent radial sheath

    International Nuclear Information System (INIS)

    Hazeltine, R.D.

    1988-12-01

    The boundary layer arising in the radial vicinity of a tokamak limiter is examined, with special reference to the TEXT tokamak. It is shown that sheath structure depends upon the self-consistent effects of ion guiding-center orbit modification, as well as the radial variation of E /times/ B-induced toroidal rotation. Reasonable agreement with experiment is obtained from an idealized model which, however simplified, preserves such self-consistent effects. It is argued that the radial sheath, which occurs whenever confining magnetic field-lines lie in the plasma boundary surface, is an object of some intrinsic interest. It differs from the more familiar axial sheath because magnetized charges respond very differently to parallel and perpendicular electric fields. 11 refs., 1 fig

  1. Empire as a Geopolitical Figure

    DEFF Research Database (Denmark)

    Parker, Noel

    2010-01-01

    This article analyses the ingredients of empire as a pattern of order with geopolitical effects. Noting the imperial form's proclivity for expansion from a critical reading of historical sociology, the article argues that the principal manifestation of earlier geopolitics lay not in the nation...... but in empire. That in turn has been driven by a view of the world as disorderly and open to the ordering will of empires (emanating, at the time of geopolitics' inception, from Europe). One implication is that empires are likely to figure in the geopolitical ordering of the globe at all times, in particular...... after all that has happened in the late twentieth century to undermine nationalism and the national state. Empire is indeed a probable, even for some an attractive form of regime for extending order over the disorder produced by globalisation. Geopolitics articulated in imperial expansion is likely...

  2. A coincidental variation of the axillary artery: the brachioradial artery and the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle

    Directory of Open Access Journals (Sweden)

    Marek Konarik

    2014-09-01

    Full Text Available A case of anomalous terminal branching of the axillary artery was encountered and described in a left upper limb of a male cadaver. A series of 214 upper limbs of Caucasian race was dissected. A variant artery, stemming from the very end of the axillary artery followed a superficial course distally. It passed the cubital fossa, ran on the lateral side of the forearm as usual radial artery, crossed ventrally to the palm and terminated in the deep palmar arch. This vessel is a case of the brachioradial artery (incorrectly termed as the “radial artery with high origin”. Moreover, it was associated with another variation, concerning the aberrant posterior humeral circumflex artery passing under the tendon of the latissimus dorsi muscle. The anatomical knowledge of the axillary region is essential for radiodiagnostic, surgical and traumatologic procedures. The superficially located artery brings an elevated danger of heavy bleeding in all unexpected situations, its variant branching can cause problems in radial catheterization procedures and the anomalously coursing other arterial variant poses an elevated danger in surgical procedures concerning the surgical neck of humerus.

  3. Detonation in supersonic radial outflow

    KAUST Repository

    Kasimov, Aslan R.

    2014-11-07

    We report on the structure and dynamics of gaseous detonation stabilized in a supersonic flow emanating radially from a central source. The steady-state solutions are computed and their range of existence is investigated. Two-dimensional simulations are carried out in order to explore the stability of the steady-state solutions. It is found that both collapsing and expanding two-dimensional cellular detonations exist. The latter can be stabilized by putting several rigid obstacles in the flow downstream of the steady-state sonic locus. The problem of initiation of standing detonation stabilized in the radial flow is also investigated numerically. © 2014 Cambridge University Press.

  4. Distal vertebral artery reconstruction when managing vertebrobasilar insufficiency

    Directory of Open Access Journals (Sweden)

    D. M. Galaktionov

    2017-11-01

    Full Text Available This article presents a literature review devoted to the reconstruction of the distal vertebral artery and a clinical case of successful surgical treatment of a patient suffering from vertebrobasilar insufficiency caused by occlusion of the vertebral artery in a proximal segment. The external carotid artery-distal vertebral artery bypass was performed by using the radial artery.Received 27 February 2017. Revised 25 July 2017. Accepted 3 August 2017.Funding: The study did not have sponsorship.Conflict of interest: The authors declare no conflict of interest. 

  5. Vortex Whistle in Radial Intake

    National Research Council Canada - National Science Library

    Tse, Man-Chun

    2004-01-01

    In a radial-to-axial intake with inlet guide vanes (IGV) at the entry, a strong flow circulation Gamma can be generated from the tangential flow components created by the IGVs when their setting exceed about halfclosing (approx. 45 deg...

  6. Dose-dependent headache response and dilatation of limb and extracranial arteries after three doses of 5-isosorbide-mononitrate

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Nielsen, T H; Garre, K

    1992-01-01

    of the temporal artery, but not for the radial artery. It is concluded that headache after 5-ISMN is caused by arterial dilatation or by mechanisms responsible for the arterial dilatation. Ultrasound monitoring of arterial diameters is an important and sensitive tool in the evaluation of nitrates and other...... and placebo on separate days. The diameters of the radial and superficial temporal arteries were repeatedly measured with high frequency ultrasound and pain was scored using a 10 point verbal scale. A clear dose-relationship was found for plasma concentrations and headache, and for changes in the diameter...

  7. Radial head dislocation during proximal radial shaft osteotomy.

    Science.gov (United States)

    Hazel, Antony; Bindra, Randy R

    2014-03-01

    The following case report describes a 48-year-old female patient with a longstanding both-bone forearm malunion, who underwent osteotomies of both the radius and ulna to improve symptoms of pain and lack of rotation at the wrist. The osteotomies were templated preoperatively. During surgery, after performing the planned radial shaft osteotomy, the authors recognized that the radial head was subluxated. The osteotomy was then revised from an opening wedge to a closing wedge with improvement of alignment and rotation. The case report discusses the details of the operation, as well as ways in which to avoid similar shortcomings in the future. Copyright © 2014 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  8. Are figure legends sufficient? Evaluating the contribution of associated text to biomedical figure comprehension.

    Science.gov (United States)

    Yu, Hong; Agarwal, Shashank; Johnston, Mark; Cohen, Aaron

    2009-01-06

    Biomedical scientists need to access figures to validate research facts and to formulate or to test novel research hypotheses. However, figures are difficult to comprehend without associated text (e.g., figure legend and other reference text). We are developing automated systems to extract the relevant explanatory information along with figures extracted from full text articles. Such systems could be very useful in improving figure retrieval and in reducing the workload of biomedical scientists, who otherwise have to retrieve and read the entire full-text journal article to determine which figures are relevant to their research. As a crucial step, we studied the importance of associated text in biomedical figure comprehension. Twenty subjects evaluated three figure-text combinations: figure+legend, figure+legend+title+abstract, and figure+full-text. Using a Likert scale, each subject scored each figure+text according to the extent to which the subject thought he/she understood the meaning of the figure and the confidence in providing the assigned score. Additionally, each subject entered a free text summary for each figure-text. We identified missing information using indicator words present within the text summaries. Both the Likert scores and the missing information were statistically analyzed for differences among the figure-text types. We also evaluated the quality of text summaries with the text-summarization evaluation method the ROUGE score. Our results showed statistically significant differences in figure comprehension when varying levels of text were provided. When the full-text article is not available, presenting just the figure+legend left biomedical researchers lacking 39-68% of the information about a figure as compared to having complete figure comprehension; adding the title and abstract improved the situation, but still left biomedical researchers missing 30% of the information. When the full-text article is available, figure comprehension

  9. [Alterations in arterial compliance of dyslipidemic patients].

    Science.gov (United States)

    Clara, Fernando Mario; Corral, Pablo; Blanco, Gustavo Hector; Scandurra, Adriana Graciela; Meschino, Gustavo Javier

    2015-01-01

    We studied the alteration on the distensibility of the arterial walls caused by dyslipidemia LDLc dependent, along the decades of life, by means of a study of the radial artery pulse wave. We made an analysis of the radial artery pulse wave records acquired by means a movement displacement sensor, placed on radial palpation area. We recruited 100 dyslipidemic men without other cardiovascular risk factors, between the 3rd and the 6th decade. We identified the reflected wave in the records and we computed the augmentation index in order to quantify its amplitude and position. This index is useful to assess the endothelial dysfunction. Besides, we defined a velocity coefficient as the ratio between the size of the individuals and the delay time between the peak of the systolic wave and the arrival of the reflected wave. Results were compared against those obtained in a group of 161 healthy volunteers. We found that dyslipidemic patients presented augmentation index values similar to controls until the fourth decade, increasing thereafter with significant differences only in the 6th decade. No significant differences were found in the velocity index in any of the ages studied. We conclude that alterations produced by dyslipidemia take decades to manifest, and they begin affecting the mechanism of vasodilation of distal arteries with highest proportion of smooth muscle, without altering the proximal conduit arteries with more elastin content. Copyright © 2013 Sociedad Española de Arteriosclerosis. Published by Elsevier España. All rights reserved.

  10. Figure text extraction in biomedical literature.

    Directory of Open Access Journals (Sweden)

    Daehyun Kim

    2011-01-01

    Full Text Available Figures are ubiquitous in biomedical full-text articles, and they represent important biomedical knowledge. However, the sheer volume of biomedical publications has made it necessary to develop computational approaches for accessing figures. Therefore, we are developing the Biomedical Figure Search engine (http://figuresearch.askHERMES.org to allow bioscientists to access figures efficiently. Since text frequently appears in figures, automatically extracting such text may assist the task of mining information from figures. Little research, however, has been conducted exploring text extraction from biomedical figures.We first evaluated an off-the-shelf Optical Character Recognition (OCR tool on its ability to extract text from figures appearing in biomedical full-text articles. We then developed a Figure Text Extraction Tool (FigTExT to improve the performance of the OCR tool for figure text extraction through the use of three innovative components: image preprocessing, character recognition, and text correction. We first developed image preprocessing to enhance image quality and to improve text localization. Then we adapted the off-the-shelf OCR tool on the improved text localization for character recognition. Finally, we developed and evaluated a novel text correction framework by taking advantage of figure-specific lexicons.The evaluation on 382 figures (9,643 figure texts in total randomly selected from PubMed Central full-text articles shows that FigTExT performed with 84% precision, 98% recall, and 90% F1-score for text localization and with 62.5% precision, 51.0% recall and 56.2% F1-score for figure text extraction. When limiting figure texts to those judged by domain experts to be important content, FigTExT performed with 87.3% precision, 68.8% recall, and 77% F1-score. FigTExT significantly improved the performance of the off-the-shelf OCR tool we used, which on its own performed with 36.6% precision, 19.3% recall, and 25.3% F1-score for

  11. Heart transplantation and arterial elasticity

    Directory of Open Access Journals (Sweden)

    Colvin-Adams M

    2013-12-01

    Full Text Available Monica Colvin-Adams,1 Nonyelum Harcourt,1 Robert LeDuc,2 Ganesh Raveendran,1 Yassir Sonbol,3 Robert Wilson,1 Daniel Duprez11Cardiovascular Division, University of Minnesota, Minneapolis, MN, USA; 2Division of Biostatistics University of Minnesota, Minneapolis, MN, USA; 3Cardiovascular Division, St Luke's Hospital System, Sugar Land, TX, USAObjective: Arterial elasticity is a functional biomarker that has predictive value for cardiovascular morbidity and mortality in nontransplant populations. There is little information regarding arterial elasticity in heart transplant recipients. This study aimed to characterize small (SAE and large (LAE artery elasticity in heart transplant recipients in comparison with an asymptomatic population free of overt cardiovascular disease. A second goal was to identify demographic and clinical factors associated with arterial elasticity in this unique population.Methods: Arterial pulse waveform was registered noninvasively at the radial artery in 71 heart transplant recipients between 2008 and 2010. SAEs and LAEs were derived from diastolic pulse contour analysis. Comparisons were made to a healthy cohort of 1,808 participants selected from our prevention clinic database. Multiple regression analyses were performed to evaluate associations between risk factors and SAE and LAE within the heart transplant recipients.Results: LAE and SAE were significantly lower in heart transplant recipients than in the normal cohort (P <0.01 and P < 0.0001, respectively. Female sex and history of ischemic cardiomyopathy were significantly associated with reduced LAE and SAE. Older age and the presence of moderate cardiac allograft vasculopathy were also significantly associated with reduced SAE. Transplant duration was associated with increased SAE.Conclusion: Heart transplants are associated with peripheral endothelial dysfunction and arterial stiffness, as demonstrated by a significant reduction in SAE and LAE when compared with a

  12. RADIAL STABILITY IN STRATIFIED STARS

    International Nuclear Information System (INIS)

    Pereira, Jonas P.; Rueda, Jorge A.

    2015-01-01

    We formulate within a generalized distributional approach the treatment of the stability against radial perturbations for both neutral and charged stratified stars in Newtonian and Einstein's gravity. We obtain from this approach the boundary conditions connecting any two phases within a star and underline its relevance for realistic models of compact stars with phase transitions, owing to the modification of the star's set of eigenmodes with respect to the continuous case

  13. Velocidades radiales en Collinder 121

    Science.gov (United States)

    Arnal, M.; Morrell, N.

    Se han llevado a cabo observaciones espectroscópicas de unas treinta estrellas que son posibles miembros del cúmulo abierto Collinder 121. Las mismas fueron realizadas con el telescopio de 2.15m del Complejo Astronómico El Leoncito (CASLEO). El análisis de las velocidades radiales derivadas del material obtenido, confirma la realidad de Collinder 121, al menos desde el punto de vista cinemático. La velocidad radial baricentral (LSR) del cúmulo es de +17 ± 3 km.s-1. Esta velocidad coincide, dentro de los errores, con la velocidad radial (LSR) de la nebulosa anillo S308, la cual es de ~20 ± 10 km.s-1. Como S308 se encuentra físicamente asociada a la estrella Wolf-Rayet HD~50896, es muy probable que esta última sea un miembro de Collinder 121. Desde un punto de vista cinemático, la supergigante roja HD~50877 (K3Iab) también pertenecería a Collinder 121. Basándonos en la pertenencia de HD~50896 a Collinder 121, y en la interacción encontrada entre el viento de esta estrella y el medio interestelar circundante a la misma, se estima para este cúmulo una distancia del orden de 1 kpc.

  14. The latest figures on uranium

    International Nuclear Information System (INIS)

    Vance, R.

    2010-01-01

    According to the latest figures on uranium, soon to be published by the NEA, uranium resources, production and demand are all on the rise. Exploration efforts have increased recently in line with the expected expansion of nuclear energy in the coming years. Total identified resources have grown and are now sufficient to cover 100 years of supply at 2008 rates of consumption. Costs of production have, however, also increased. This article is based on the latest edition of the 'Red Book', Uranium 2009: Resources, Production and Demand, which presents the results of the most recent biennial review of world uranium market fundamentals and a statistical profile of the world uranium industry as of 1 January 2009. It contains official data provided by OECD Nuclear Energy Agency (NEA) and International Atomic Energy Agency (IAEA) member countries on uranium exploration, resources, production and reactor-related requirements. Projections of nuclear generating capacity and reactor-related uranium requirements through 2035 are also provided as well as a discussion of long-term uranium supply and demand issues. Despite recent declines stemming from the global financial crisis, world demand for electricity is expected to continue to grow significantly over the next several decades to meet the needs of an increasing population and economic growth. The recognition by an increasing number of governments that nuclear power can produce competitively priced, base-load electricity that is essentially free of greenhouse gas emissions, coupled with the role that nuclear can play in enhancing security of energy supply, increases the prospects for growth in nuclear generating capacity, although the magnitude of that growth remains to be determined. Regardless of the role that nuclear energy ultimately plays in meeting rising electricity demand, the uranium resource base is more than adequate to meet projected requirements. Meeting even high-case requirements to 2035 would consume less

  15. Figure-ground assignment in pigeons: evidence for a figural benefit.

    Science.gov (United States)

    Lazareva, Olga E; Castro, Leyre; Vecera, Shaun P; Wasserman, Edward A

    2006-07-01

    Four pigeons discriminated whether a target spot appeared on a colored figural shape or on a differently colored background by first pecking the target and then reporting its location: on the figure or the background. We recorded three dependent variables: target detection time, choice response time, and choice accuracy. The birds were faster to detect the target, to report its location, and to learn the correct response on figure trials than on background trials. Later tests suggested that the pigeons might have attended to the figural region as a whole rather than using local properties in performing the figure-background discrimination. The location of the figural region did not affect figure-ground assignment. Finally, when 4 other pigeons had to detect and peck the target without making a choice report, no figural advantage emerged in target detection time, suggesting that the birds' attention may not have been automatically summoned to the figural region.

  16. Arterial stick

    Science.gov (United States)

    ... be some throbbing. Why the Test Is Performed Blood transports oxygen, nutrients, waste products, and other materials within ... venous blood) mainly in its content of dissolved gases . Testing arterial blood shows the makeup of the blood before any ...

  17. Equilibrium figures in geodesy and geophysics.

    Science.gov (United States)

    Moritz, H.

    There is an enormous literature on geodetic equilibrium figures, but the various works have not always been interrelated, also for linguistic reasons (English, French, German, Italian, Russian). The author attempts to systematize the various approaches and to use the standard second-order theory for a study of the deviation of the actual earth and of the equipotential reference ellipsoid from an equilibrium figure.

  18. "Blessed": Musical Talent, Smartness, & Figured Identities

    Science.gov (United States)

    Hoffman, Adria R.

    2015-01-01

    The purpose of this study is to explore smartness and talent as social constructs. Drawing on Holland et al.'s (1998) figured identities, this article explores the figuring of abilities by elucidating the voices of African American high school chorus students. Critical Race Theory (CRT) helps to unpack normalized language and practices that…

  19. Feature Assignment in Perception of Auditory Figure

    Science.gov (United States)

    Gregg, Melissa K.; Samuel, Arthur G.

    2012-01-01

    Because the environment often includes multiple sounds that overlap in time, listeners must segregate a sound of interest (the auditory figure) from other co-occurring sounds (the unattended auditory ground). We conducted a series of experiments to clarify the principles governing the extraction of auditory figures. We distinguish between auditory…

  20. Human Figure Drawings: Abusing the Abused.

    Science.gov (United States)

    Bardos, Achilles N.

    1993-01-01

    Responds to previous article (Motta, Little, and Tobin, this issue) which reviewed data-based studies on figure drawings and found little support for their validity or use in assessing personality, behavior, emotion, or intellectual functioning. Notes recent approaches to interpretation of human figure drawings and cites flaws in argument against…

  1. Figuring Out Food Labels (For Kids)

    Science.gov (United States)

    ... First Aid & Safety Doctors & Hospitals Videos Recipes for Kids Kids site Sitio para niños How the Body Works ... English Español Figuring Out Food Labels KidsHealth / For Kids / Figuring Out Food Labels What's in this article? ...

  2. Figure-associated text summarization and evaluation.

    Directory of Open Access Journals (Sweden)

    Balaji Polepalli Ramesh

    Full Text Available Biomedical literature incorporates millions of figures, which are a rich and important knowledge resource for biomedical researchers. Scientists need access to the figures and the knowledge they represent in order to validate research findings and to generate new hypotheses. By themselves, these figures are nearly always incomprehensible to both humans and machines and their associated texts are therefore essential for full comprehension. The associated text of a figure, however, is scattered throughout its full-text article and contains redundant information content. In this paper, we report the continued development and evaluation of several figure summarization systems, the FigSum+ systems, that automatically identify associated texts, remove redundant information, and generate a text summary for every figure in an article. Using a set of 94 annotated figures selected from 19 different journals, we conducted an intrinsic evaluation of FigSum+. We evaluate the performance by precision, recall, F1, and ROUGE scores. The best FigSum+ system is based on an unsupervised method, achieving F1 score of 0.66 and ROUGE-1 score of 0.97. The annotated data is available at figshare.com (http://figshare.com/articles/Figure_Associated_Text_Summarization_and_Evaluation/858903.

  3. Figure-associated text summarization and evaluation.

    Science.gov (United States)

    Polepalli Ramesh, Balaji; Sethi, Ricky J; Yu, Hong

    2015-01-01

    Biomedical literature incorporates millions of figures, which are a rich and important knowledge resource for biomedical researchers. Scientists need access to the figures and the knowledge they represent in order to validate research findings and to generate new hypotheses. By themselves, these figures are nearly always incomprehensible to both humans and machines and their associated texts are therefore essential for full comprehension. The associated text of a figure, however, is scattered throughout its full-text article and contains redundant information content. In this paper, we report the continued development and evaluation of several figure summarization systems, the FigSum+ systems, that automatically identify associated texts, remove redundant information, and generate a text summary for every figure in an article. Using a set of 94 annotated figures selected from 19 different journals, we conducted an intrinsic evaluation of FigSum+. We evaluate the performance by precision, recall, F1, and ROUGE scores. The best FigSum+ system is based on an unsupervised method, achieving F1 score of 0.66 and ROUGE-1 score of 0.97. The annotated data is available at figshare.com (http://figshare.com/articles/Figure_Associated_Text_Summarization_and_Evaluation/858903).

  4. Figures of merit for surface plasmon waveguides

    Science.gov (United States)

    Berini, Pierre

    2006-12-01

    Three figures of merit are proposed as quality measures for surface plasmon waveguides. They are defined as benefit-to-cost ratios where the benefit is confinement and the cost is attenuation. Three different ways of measuring confinement are considered, leading to three figures of merit. One of the figures of merit is connected to the quality factor. The figures of merit were then used to assess and compare the wavelength response of hree popular 1-D surface plasmon waveguides: the single metal-dielectric interface, the metal slab bounded by dielectric and the dielectric slab bounded by metal. Closed form expressions are given for the figures of merit of the single metal-dielectric interface.

  5. Exceptional circles of radial potentials

    International Nuclear Information System (INIS)

    Music, M; Perry, P; Siltanen, S

    2013-01-01

    A nonlinear scattering transform is studied for the two-dimensional Schrödinger equation at zero energy with a radial potential. Explicit examples are presented, both theoretically and computationally, of potentials with nontrivial singularities in the scattering transform. The singularities arise from non-uniqueness of the complex geometric optics solutions that define the scattering transform. The values of the complex spectral parameter at which the singularities appear are called exceptional points. The singularity formation is closely related to the fact that potentials of conductivity type are ‘critical’ in the sense of Murata. (paper)

  6. Emergent Endovascular Management of Acute Arterial Bleeding ...

    African Journals Online (AJOL)

    multiruka1

    little attention has been paid to the novel endovascular options available .... Fig 1b. Fig 1c. Figure 1a: Mass at gastric fundus enhanced in post contrast CT abdomen. ... 1c: Left gastric artery super selectively coiled to occlusion. Fig 2a. Fig 2b.

  7. Arterial stiffness

    Directory of Open Access Journals (Sweden)

    Ursula Quinn

    2012-09-01

    Full Text Available Measurements of biomechanical properties of arteries have become an important surrogate outcome used in epidemiological and interventional cardiovascular research. Structural and functional differences of vessels in the arterial tree result in a dampening of pulsatility and smoothing of blood flow as it progresses to capillary level. A loss of arterial elastic properties results a range of linked pathophysiological changes within the circulation including increased pulse pressure, left ventricular hypertrophy, subendocardial ischaemia, vessel endothelial dysfunction and cardiac fibrosis. With increased arterial stiffness, the microvasculature of brain and kidneys are exposed to wider pressure fluctuations and may lead to increased risk of stroke and renal failure. Stiffening of the aorta, as measured by the gold-standard technique of aortic Pulse Wave Velocity (aPWV, is independently associated with adverse cardiovascular outcomes across many different patient groups and in the general population. Therefore, use of aPWV has been proposed for early detection of vascular damage and individual cardiovascular risk evaluation and it seems certain that measurement of arterial stiffness will become increasingly important in future clinical care. In this review we will consider some of the pathophysiological processes that result from arterial stiffening, how it is measured and factors that may drive it as well as potential avenues for therapy. In the face of an ageing population where mortality from atheromatous cardiovascular disease is falling, pathology associated with arterial stiffening will assume ever greater importance. Therefore, understanding these concepts for all clinicians involved in care of patients with cardiovascular disease will become vital.

  8. Perforator anatomy of the radial forearm free flap versus the ulnar forearm free flap for head and neck reconstruction.

    Science.gov (United States)

    Hekner, D D; Roeling, T A P; Van Cann, E M

    2016-08-01

    The aim of this study was to investigate the vascular anatomy of the distal forearm in order to optimize the choice between the radial forearm free flap and the ulnar forearm free flap and to select the best site to harvest the flap. The radial and ulnar arteries of seven fresh cadavers were injected with epoxy resin (Araldite) and the perforating arteries were dissected. The number of clinically relevant perforators from the radial and ulnar arteries was not significantly different in the distal forearm. Most perforators were located in the proximal half of the distal one third, making this part probably the safest location for flap harvest. Close to the wrist, i.e. most distally, there were more perforators on the ulnar side than on the radial side. The ulnar artery stained 77% of the skin surface area of the forearm, showing the ulnar forearm free flap to be more suitable than the radial forearm free flap for the restoration of large defects. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  9. Carotid artery surgery

    Science.gov (United States)

    Carotid endarterectomy; CAS surgery; Carotid artery stenosis - surgery; Endarterectomy - carotid artery ... through the catheter around the blocked area during surgery. Your carotid artery is opened. The surgeon removes ...

  10. Illusory object motion in the centre of a radial pattern: The Pursuit–Pursuing illusion

    Science.gov (United States)

    Ito, Hiroyuki

    2012-01-01

    A circular object placed in the centre of a radial pattern consisting of thin sectors was found to cause a robust motion illusion. During eye-movement pursuit of a moving target, the presently described stimulus produced illusory background-object motion in the same direction as that of the eye movement. In addition, the display induced illusory stationary perception of a moving object against the whole display motion. In seven experiments, the characteristics of the illusion were examined in terms of luminance relationships and figural characteristics of the radial pattern. Some potential explanations for these findings are discussed. PMID:23145267

  11. Illusory object motion in the centre of a radial pattern: The Pursuit-Pursuing illusion.

    Science.gov (United States)

    Ito, Hiroyuki

    2012-01-01

    A circular object placed in the centre of a radial pattern consisting of thin sectors was found to cause a robust motion illusion. During eye-movement pursuit of a moving target, the presently described stimulus produced illusory background-object motion in the same direction as that of the eye movement. In addition, the display induced illusory stationary perception of a moving object against the whole display motion. In seven experiments, the characteristics of the illusion were examined in terms of luminance relationships and figural characteristics of the radial pattern. Some potential explanations for these findings are discussed.

  12. Using Figure and Concept Knowledge in Geometry

    Directory of Open Access Journals (Sweden)

    Yavuz Karpuz

    2014-08-01

    Full Text Available In this study, we aim to investigate how students build interaction between concepts and figure in geometry. For this purpose we developed two type data collection tool. First one called shapely is formed eight open ended question which has concepts and figure. Second one called shapeless is formed eight open ended question which has only concepts. To prepare this data collection tools’ difficulty level we took two math teachers’ opinions. Developed data collection tools were applied 120 students at 9th grade and 11th grade in Trabzon Gazi Anatolian High School. First of all we applied shapeless questions. One month later we applied shapely questions. We investigated students’ answer and the data showed that students more succeed in shapely questions than shapeless questions. We concluded that the difficulty of solving shapeless question result from students didn’t manage to draw figure representing concept knowledge or draw wrong figure, figure drawn by students can’t fulfıl generalizability condition and students who have little knowledge of concept in geometry is under the influence of prototype figure.Key Words:    Figural concepts theory, geometrical reasoning, geometry teaching

  13. Radial smoothing and closed orbit

    International Nuclear Information System (INIS)

    Burnod, L.; Cornacchia, M.; Wilson, E.

    1983-11-01

    A complete simulation leading to a description of one of the error curves must involve four phases: (1) random drawing of the six set-up points within a normal population having a standard deviation of 1.3 mm; (b) random drawing of the six vertices of the curve in the sextant mode within a normal population having a standard deviation of 1.2 mm. These vertices are to be set with respect to the axis of the error lunes, while this axis has as its origins the positions defined by the preceding drawing; (c) mathematical definition of six parabolic curves and their junctions. These latter may be curves with very slight curvatures, or segments of a straight line passing through the set-up point and having lengths no longer than one LSS. Thus one gets a mean curve for the absolute errors; (d) plotting of the actually observed radial positions with respect to the mean curve (results of smoothing)

  14. Waves on radial film flows

    Science.gov (United States)

    Cholemari, Murali R.; Arakeri, Jaywant H.

    2005-08-01

    We study the stability of surface waves on the radial film flow created by a vertical cylindrical water jet striking a horizontal plate. In such flows, surface waves have been found to be unstable and can cause transition to turbulence. This surface-wave-induced transition is different from the well-known Tollmien-Schlichting wave-induced transition. The present study aims at understanding the instability and the transition process. We do a temporal stability analysis by assuming the flow to be locally two-dimensional but including spatial variations to first order in the basic flow. The waves are found to be dispersive, mostly unstable, and faster than the mean flow. Spatial variation is the major destabilizing factor. Experiments are done to test the results of the linear stability analysis and to document the wave breakup and transition. Comparison between theory and experiments is fairly good and indicates the adequacy of the model.

  15. Radial flow gas dynamic laser

    International Nuclear Information System (INIS)

    Damm, F.C.

    1975-01-01

    The unique gas dynamic laser provides outward radial supersonic flow from a toroidal shaped stacked array of a plurality of nozzles, through a diffuser having ring shaped and/or linear shaped vanes, and through a cavity which is cylindrical and concentric with the stacked array, with the resultant laser beam passing through the housing parallel to the central axis of the diffuser which is coincident with the axis of the gas dynamic laser. Therefore, greater beam extraction flexibility is attainable, because of fewer flow shock disturbances, as compared to the conventional unidirectional flow gas dynamic laser in which unidirectional supersonic flow sweeps through a rectangular cavity and is exhausted through a two-dimensional diffuser. (auth)

  16. Ulnar nerve entrapment complicating radial head excision

    Directory of Open Access Journals (Sweden)

    Kevin Parfait Bienvenu Bouhelo-Pam

    Full Text Available Introduction: Several mechanisms are involved in ischemia or mechanical compression of ulnar nerve at the elbow. Presentation of case: We hereby present the case of a road accident victim, who received a radial head excision for an isolated fracture of the radial head and complicated by onset of cubital tunnel syndrome. This outcome could be the consequence of an iatrogenic valgus of the elbow due to excision of the radial head. Hitherto the surgical treatment of choice it is gradually been abandoned due to development of radial head implant arthroplasty. However, this management option is still being performed in some rural centers with low resources. Discussion: The radial head plays an important role in the stability of the elbow and his iatrogenic deformity can be complicated by cubital tunnel syndrome. Conclusion: An ulnar nerve release was performed with favorable outcome. Keywords: Cubital tunnel syndrome, Peripheral nerve palsy, Radial head excision, Elbow valgus

  17. Arterial embolism

    Science.gov (United States)

    ... when a clot in a vein enters the right side of the heart and passes through a hole into the left side. The clot can then move to an artery and block blood flow to the brain (stroke) or other organs. If a clot involves ...

  18. Stirling Engine With Radial Flow Heat Exchangers

    Science.gov (United States)

    Vitale, N.; Yarr, George

    1993-01-01

    Conflict between thermodynamical and structural requirements resolved. In Stirling engine of new cylindrical configuration, regenerator and acceptor and rejector heat exchangers channel flow of working gas in radial direction. Isotherms in regenerator ideally concentric cylinders, and gradient of temperature across regenerator radial rather than axial. Acceptor and rejector heat exchangers located radially inward and outward of regenerator, respectively. Enables substantial increase in power of engine without corresponding increase in diameter of pressure vessel.

  19. Reduced arterial diameter during static exercise in humans

    DEFF Research Database (Denmark)

    Olesen, H L; Mitchell, J H; Friedman, D B

    1995-01-01

    In eight subjects luminal diameter of the resting limb radial and dorsalis pedis arteries was determined by high-resolution ultrasound (20 MHz). This measurement was followed during rest and during 2 min of static handgrip or of one-leg knee extension at 30% of maximal voluntary contraction...... exertion was approximately 15 units after both types of exercise. The dorsalis pedis arterial diameter was 1.50 +/- 0.20 mm (mean and SE) and the radial AD 2.45 +/- 0.12 mm. During both types of contractions the luminal diameters decreased approximately 3.5% within the first 30 s (P

  20. Presenting Fake Figures: A Tool to Teach Effective Scientific Figure Design

    Directory of Open Access Journals (Sweden)

    Veronica A. Segarra

    2013-08-01

    Full Text Available As trained scientists, we become adept not only at analyzing and understanding figures in the scientific literature, but also at designing figures to effectively represent our own data and findings. As educators, we strive to pass on these skills to our students, some of whom will ultimately become scientists themselves. Conveying the principles of effective figure design can be challenging, particularly when students have had little exposure to the process of reading scientific literature, much less writing a piece of scientific literature. Improvisational activities in the classroom reinforce teaching goals such as spontaneity, risk-taking, creativity, communication skills, team-building, and critical thinking (2. Indeed, improv training for scientists is becoming more common, helping scientists to communicate more spontaneously about their work and connect with their audience (1. In this article, we present an improvisational game that can aid in the teaching of effective scientific figure design. This “Present-a-Fake-Figure Exercise” is applicable to both the classroom and laboratory settings. In this learning activity, students improvise presenting fake scientific figures to an audience of their peers. These fake figures are prepared beforehand by the instructor and exemplify the do’s and don’ts of scientific figure design. Some of the learning outcomes of the activity include (1 identifying what makes a scientific figure cohesive, easy to analyze, and reader-friendly, and (2 identifying strategies that are useful in the design of a multi-panel figure to convey a scientific story.

  1. Radial head button holing: a cause of irreducible anterior radial head dislocation

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Su-Mi; Chai, Jee Won; You, Ja Yeon; Park, Jina [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Radiology, Seoul (Korea, Republic of); Bae, Kee Jeong [Seoul National University Seoul Metropolitan Government Boramae Medical Center, Department of Orthopedic Surgery, Seoul (Korea, Republic of)

    2016-10-15

    ''Buttonholing'' of the radial head through the anterior joint capsule is a known cause of irreducible anterior radial head dislocation associated with Monteggia injuries in pediatric patients. To the best of our knowledge, no report has described an injury consisting of buttonholing of the radial head through the annular ligament and a simultaneous radial head fracture in an adolescent. In the present case, the radiographic findings were a radial head fracture with anterior dislocation and lack of the anterior fat pad sign. Magnetic resonance imaging (MRI) clearly demonstrated anterior dislocation of the fractured radial head through the torn annular ligament. The anterior joint capsule and proximal portion of the annular ligament were interposed between the radial head and capitellum, preventing closed reduction of the radial head. Familiarity with this condition and imaging findings will aid clinicians to make a proper diagnosis and fast decision to perform an open reduction. (orig.)

  2. Purely temporal figure-ground segregation.

    Science.gov (United States)

    Kandil, F I; Fahle, M

    2001-05-01

    Visual figure-ground segregation is achieved by exploiting differences in features such as luminance, colour, motion or presentation time between a figure and its surround. Here we determine the shortest delay times required for figure-ground segregation based on purely temporal features. Previous studies usually employed stimulus onset asynchronies between figure- and ground-containing possible artefacts based on apparent motion cues or on luminance differences. Our stimuli systematically avoid these artefacts by constantly showing 20 x 20 'colons' that flip by 90 degrees around their midpoints at constant time intervals. Colons constituting the background flip in-phase whereas those constituting the target flip with a phase delay. We tested the impact of frequency modulation and phase reduction on target detection. Younger subjects performed well above chance even at temporal delays as short as 13 ms, whilst older subjects required up to three times longer delays in some conditions. Figure-ground segregation can rely on purely temporal delays down to around 10 ms even in the absence of luminance and motion artefacts, indicating a temporal precision of cortical information processing almost an order of magnitude lower than the one required for some models of feature binding in the visual cortex [e.g. Singer, W. (1999), Curr. Opin. Neurobiol., 9, 189-194]. Hence, in our experiment, observers are unable to use temporal stimulus features with the precision required for these models.

  3. Congenital Arterial Thrombosis in Newborn: a Case Report

    OpenAIRE

    Özdemir, Özmert M. A.; Özdemir, Yavuz; Kılıç, İlknur; Güleç, Bülent; Sücüllü, İlker; Küçüktaşçı, Kazım; Filiz, Ali İlker; Gürses, Dolunay; Karaca, Abdullah; Oto, Murat; Çetin, Gökhan Ozan; Caner, Vildan

    2014-01-01

    Neonatal thrombosis is a serious event that can cause mortality or severe morbidity. Although catheters are the most common cause of neonatal thrombosis, spontaneous events can also occur. Arterial thrombosis is very rare and accounts for approximately half of all thrombotic events in neonates. Genetic prothrombotic risk factors may affect the occurence of neonatal thrombosis. In this report, a case of left brachial, radial, and ulnar arterial thrombosis associated with methylene-tetrahydrofo...

  4. Figuring process of potassium dihydrogen phosphate crystal using ion beam figuring technology.

    Science.gov (United States)

    Li, Furen; Xie, Xuhui; Tie, Guipeng; Hu, Hao; Zhou, Lin

    2017-09-01

    Currently, ion beam figuring (IBF) technology has presented many excellent performances in figuring potassium dihydrogen phosphate (KDP) crystals, such as it is a noncontact figuring process and it does not require polishing fluid. So, it is a very clean figuring process and does not introduce any impurities. However, the ion beam energy deposited on KDP crystal will heat the KDP crystal and may generate cracks on it. So, it is difficult directly using IBF technology to figure KDP crystal, as oblique incident IBF (OI-IBF) has lower heat deposition, higher removal rate, and smoother surface roughness compared to normal incident IBF. This paper studied the process of using OI-IBF to figure KDP crystal. Removal rates and removal functions at different incident angles were first investigated. Then heat depositions on a test work piece were obtained through experiments. To validate the figuring process, a KDP crystal with a size of 200  mm×200  mm×12  mm was figured by OI-IBF. After three iterations using the OI-IBF process, the surface error decreases from the initial values with PV 1.986λ RMS 0.438λ to PV 0.215λ RMS 0.035λ. Experimental results indicate that OI-IBF is feasible and effective to figure KDP crystals.

  5. Photoelectric Radial Velocities, Paper XIX Additional Spectroscopic ...

    Indian Academy of Sciences (India)

    ian velocity curve that does justice to the measurements, but it cannot be expected to have much predictive power. Key words. Stars: late-type—stars: radial velocities—spectroscopic binaries—orbits. 0. Preamble. The 'Redman K stars' are a lot of seventh-magnitude K stars whose radial velocities were first observed by ...

  6. Radial velocities of RR Lyrae stars

    International Nuclear Information System (INIS)

    Hawley, S.L.; Barnes, T.G. III

    1985-01-01

    283 spectra of 57 RR Lyrae stars have been obtained using the 2.1-m telescope at McDonald Observatory. Radial velocities were determined using a software cross-correlation technique. New mean radial velocities were determined for 46 of the stars. 11 references

  7. Concepts of radial and angular kinetic energies

    DEFF Research Database (Denmark)

    Dahl, Jens Peder; Schleich, W.P.

    2002-01-01

    We consider a general central-field system in D dimensions and show that the division of the kinetic energy into radial and angular parts proceeds differently in the wave-function picture and the Weyl-Wigner phase-space picture, Thus, the radial and angular kinetic energies are different quantities...

  8. Energy in Sweden. Facts and figures 2005

    International Nuclear Information System (INIS)

    2005-12-01

    Energy in Sweden. Facts and Figures 2005 contains the tabular data for most of the diagrams in the main publication. These data consist primarily of the results of the Agency's processing of basic data from Statistics Sweden. Facts and Figures is available at www.stem.se in pdf- and excel file formats. With effect from the 2001 edition, statistics are of preliminary character for the two preceding years (2003 and 2004). Breakdowns into certain types of fuels vary somewhat depending on whether preliminary or final data has been used. Further information about the statistics can be found in Energy in Sweden, chapter 8 Energy Facts

  9. Figure-ground segregation modulates apparent motion.

    Science.gov (United States)

    Ramachandran, V S; Anstis, S

    1986-01-01

    We explored the relationship between figure-ground segmentation and apparent motion. Results suggest that: static elements in the surround can eliminate apparent motion of a cluster of dots in the centre, but only if the cluster and surround have similar "grain" or texture; outlines that define occluding surfaces are taken into account by the motion mechanism; the brain uses a hierarchy of precedence rules in attributing motion to different segments of the visual scene. Being designated as "figure" confers a high rank in this scheme of priorities.

  10. Metrics of Justice. A Sundial's Nomological Figuration.

    Science.gov (United States)

    Behrmann, Carolin

    2015-01-01

    This paper examines a polyhedral dial from the British Museum made by the instrument maker Ulrich Schniep, and discusses the status of multifunctional scientific instruments. It discerns a multifaceted iconic meaning considering different dimensions such as scientific functionality (astronomy), the complex allegorical figure of Justice (iconography), and the representation of the sovereign (politics), the court and the Kunstkammer of Albrecht v of Bavaria. As a numen mixtum the figure of "Justicia" touches different fields that go far beyond pure astronomical measurement and represents the power of the ruler as well as the rules of economic justice.

  11. Evaluation of anatomy and variations of superficial palmar arch and upper extremity arteries with CT angiography.

    Science.gov (United States)

    Kaplanoglu, Hatice; Beton, Osman

    2017-04-01

    To evaluate the abnormalities and variations of the arterial system of upper extremities and superficial palmar arch with computed tomography angiography and to guide the clinician during this procedure. A total of 156 upper extremities of 78 cases were retrospectively analyzed using computed tomography angiography. The study was approved by the local ethics committee of the hospital. From the analysis of the computed tomography angiography images, the following information was recorded; the diameters and abnormalities of radial, ulnar and brachial arteries in both upper extremities, the presence of atherosclerotic changes or stenosis in these arteries, whether the superficial palmar arch was complete or incomplete, and arterial dominance. Also, the computed tomography angiography classification of superficial palmar arch distribution and anatomic configuration was performed. The mean baseline diameters of the radial, ulnar and brachial arteries of the cases were; 2.8 ± 0.6, 2.5 ± 0.7, and 4.7 ± 0.6 mm, respectively. A complete superficial palmar arch was observed in 69.2 % of the right hands and 70.5 % of the left hands. For the superficial palmar arches on the right side, the radial artery was dominant in two and the ulnar artery was dominant in 47 with the remaining showing codominance. On the left side, the radial artery was dominant in one hand, with the ulnar artery being dominant in 49 cases, and in 28 cases, there was codominance. In the superficial palmar arch classification, four of the arches (A-D) were defined as complete and the remaining three (E-G) as incomplete. The current study clarified different variations in palmar circulation and forearm arteries to aid the surgeon during trans-radial or trans-ulnar catheterization, hemodialysis, or coronary artery bypass grafting.

  12. Modulation of radial blood flow during Braille character discrimination task.

    Science.gov (United States)

    Murata, Jun; Matsukawa, K; Komine, H; Tsuchimochi, H

    2012-03-01

    Human hands are excellent in performing sensory and motor function. We have hypothesized that blood flow of the hand is dynamically regulated by sympathetic outflow during concentrated finger perception. To identify this hypothesis, we measured radial blood flow (RBF), radial vascular conductance (RVC), heart rate (HR), and arterial blood pressure (AP) during Braille reading performed under the blind condition in nine healthy subjects. The subjects were instructed to read a flat plate with raised letters (Braille reading) for 30 s by the forefinger, and to touch a blank plate as control for the Braille discrimination procedure. HR and AP slightly increased during Braille reading but remained unchanged during the touching of the blank plate. RBF and RVC were reduced during the Braille character discrimination task (decreased by -46% and -49%, respectively). Furthermore, the changes in RBF and RVC were much greater during the Braille character discrimination task than during the touching of the blank plate (decreased by -20% and -20%, respectively). These results have suggested that the distribution of blood flow to the hand is modulated via sympathetic nerve activity during concentrated finger perception.

  13. Energy in Sweden. Facts and figures 1999

    International Nuclear Information System (INIS)

    1999-11-01

    This supplement contains the tabular data of most of the diagrams in the main publication (Energy in Sweden 1999, STEM-ET-82-1999). The figures are based on preliminary statistics, and there may be minor differences between similar data in different sections or tables etc. All table headings and notes are given in both Swedish and English

  14. Michelangelo, Leibniz and the Serpentine Figure

    NARCIS (Netherlands)

    S. van Tuinen (Sjoerd)

    2011-01-01

    textabstractAbstract In his lectures from 1987, Deleuze draws an analogy between Michelangelo‟s figures and Leibnizian substances by claiming that neither are essences but rather sources of modifications or manners of being. The best way to explore this analogy, I argue, is by focusing on

  15. The Offerings of Fringe Figures and Migrants

    Science.gov (United States)

    Engels-Schwarzpaul, A.-Chr.

    2015-01-01

    "The Western tradition", as passe-partout, includes fringe figures, émigrés and migrants. Rather than looking to resources at the core of the Western tradition to overcome its own blindnesses, I am more interested in its gaps and peripheries, where other thoughts and renegade knowledges take hold. It is in the contact zones with…

  16. Relational Reasoning in Word and in Figure

    Science.gov (United States)

    Alexander, Patricia A.; Singer, Lauren M.; Jablansky, Sophie; Hattan, Courtney

    2016-01-01

    This study investigated the relational reasoning capabilities of older adolescents and young adults when the focal assessment was a verbal and more schooled measure than 1 that was figural and more novel in its configuration. To achieve this end, the verbal test of relational reasoning (vTORR) was constructed to parallel the test of relational…

  17. Photovoltaic power production figures in 1992

    International Nuclear Information System (INIS)

    1993-01-01

    Worldwide figures of photovoltaic power production (in Mw) along 1992 are presented. Worldwide production of modules per manufacturing technology and per manufacturing companies in Europe, USA and Japan are provided as well. The review has used the following sources: ''PV News'', ''PV insider's report'' and ''systems solars''. (Author)

  18. Fading-Figure Tracing in Williams Syndrome

    Science.gov (United States)

    Nagai, Chiyoko; Inui, Toshio; Iwata, Makoto

    2011-01-01

    Williams syndrome (WS) is a neurodevelopmental disorder characterized by severe impairment of visuospatial abilities. Figure-drawing abilities, which are thought to reflect visuospatial abilities, have yet to be fully investigated in WS. The purpose of the present study was to clarify whether drawing abilities differ between WS individuals and…

  19. Edge effect correction using ion beam figuring.

    Science.gov (United States)

    Yang, Bing; Xie, Xuhui; Li, Furen; Zhou, Lin

    2017-11-10

    The edge effect is regarded as one of the most difficult technical issues for fabricating large primary mirrors, as it can greatly reduce the key performance of the optical system. Ion beam figuring (IBF) has the advantage of no edge effect, so we can use it to remove high points on the edge and improve surface accuracy. The edge local correction method (ELCM) of IBF processes only the surface edge zone, and is very different from the current full caliber figuring method (FCFM). Therefore, it is necessary to study the ELCM of IBF. In this paper, the key factors of ELCM are analyzed, such as dwell time algorithm, edge data extension methods, and the outward dimension of the starting figuring point. At the same time, the distinctions between ELCM and FCFM are compared. Finally, a 142 mm diameter fused silica mirror is fabricated to verify the validity of the theoretical of ELCM. The experimental results indicate that the figuring precision and efficiency can be obviously improved by ELCM.

  20. Anatomical study of forearm arteries with ultrasound for percutaneous coronary procedures.

    Science.gov (United States)

    Yan, Zhen-xian; Zhou, Yu-jie; Zhao, Ying-xin; Zhou, Zhi-ming; Yang, Shi-wei; Wang, Zhi-jian

    2010-04-01

    In recent years, the radial artery (RA) has become an alternative vascular access site for percutaneous coronary procedures, and the ulnar artery (UA) is another possibility. The objective of this study was to investigate the anatomy of the forearm arteries with ultrasound (US) and to evaluate the effect of the anatomy of the right RA (RRA) on the outcomes of transradial coronary procedures. The 638 patients undergoing transradial coronary procedures were examined with US for measurement of the diameters of the forearm arteries and determination of their anatomical abnormalities before the procedures. The next day the incidence of RA occlusion was recorded. The diameters of the radial and ulnar arteries were similar (P>0.05). The procedure time was longer in patients with anatomical abnormalities (Pforearm arteries of Chinese people are similar. The small diameter and anatomical abnormalities of the RRA could result in longer procedure time, more incidence of procedure failure and RA occlusion.

  1. Acute arterial occlusion - kidney

    Science.gov (United States)

    ... main artery to the kidney is called the renal artery. Reduced blood flow through the renal artery can hurt kidney function. ... need include: Duplex Doppler ultrasound exam of the renal arteries to test blood flow MRI of the kidney arteries, which can show ...

  2. INFORMATIONAL MODEL OF MENTAL ROTATION OF FIGURES

    Directory of Open Access Journals (Sweden)

    V. A. Lyakhovetskiy

    2016-01-01

    Full Text Available Subject of Study.The subject of research is the information structure of objects internal representations and operations over them, used by man to solve the problem of mental rotation of figures. To analyze this informational structure we considered not only classical dependencies of the correct answers on the angle of rotation, but also the other dependencies obtained recently in cognitive psychology. Method.The language of technical computing Matlab R2010b was used for developing information model of the mental rotation of figures. Such model parameters as the number of bits in the internal representation, an error probability in a single bit, discrete rotation angle, comparison threshold, and the degree of difference during rotation can be changed. Main Results.The model reproduces qualitatively such psychological dependencies as the linear increase of time of correct answers and the number of errors on the angle of rotation for identical figures, "flat" dependence of the time of correct answers and the number of errors on the angle of rotation for mirror-like figures. The simulation results suggest that mental rotation is an iterative process of finding a match between the two figures, each step of which can lead to a significant distortion of the internal representation of the stored objects. Matching is carried out within the internal representations that have no high invariance to rotation angle. Practical Significance.The results may be useful for understanding the role of learning (including the learning with a teacher in the development of effective information representation and operations on them in artificial intelligence systems.

  3. A unique branching pattern of the axillary artery: a case report.

    Science.gov (United States)

    Bagoji, Ishwar B; Hadimani, Gavishiddappa A; Bannur, Balappa M; Patil, B G; Bharatha, Ambadasu

    2013-12-01

    During routine dissection classes for under graduate students, we found a unique and unusual case regarding the anomalous branching in the third part of the axillary artery was terminated into subscapular arterial trunk, superficial brachial artery and deep brachial artery. The subscapular arterial trunk was origin of several important arteries as the circumflex scapular, thoracodorsal, posterior circumflex humeral, thoraco-acromial and lateral thoracic arteries. The deep brachial artery in the arm gave anterior circumflex humeral artery at the surgical neck of humerus, which terminated in the cubital fossa by dividing into radial and ulnar arteries. The superficial brachial artery gave two profunda brachii arteries, both of which passed through spiral groove, along with radial nerve and three muscular branches, to brachialis muscle. This variation is very rare. As per our knowledge, we did not find any literature which explained variations which were similar to this. The normal and abnormal anatomy of the axillary region has practical importance among vascular radiologists and surgeons and it should be known for making an accurate diagnostic interpretation.

  4. The relationship between total arterial revascularization and blood transfusion following coronary artery bypass grafting.

    Science.gov (United States)

    Djordjevic, Jasmina; Ngaage, Dumbor L

    2015-05-01

    Blood transfusion adversely affects the outcome of coronary artery bypass grafting (CABG), yet blood transfusion after CABG is still common. Total arterial revascularisation (TAR) is increasingly used in current practice but its impact on postoperative blood transfusion is not known. We reviewed the cardiothoracic and blood bank databases and collected data for isolated primary CABG patients from July 2007 to June 2012, excluding patients who had a single graft (n = 148). Perioperative variables of TAR patients (n = 745) were compared with patients who had one or more venous grafts (SVG, n = 1,761) for first-time isolated CABG. The conduits used in TAR patients were predominantly left internal thoracic and radial arteries. Matched group comparison of TAR and SVG patients was performed. The association of TAR with blood transfusion was investigated using multivariate and matched analysis. Of 2,506 patients, the 745 (29.7 %) that had TAR were generally younger, with less complex coronary artery disease and less often diabetic. After correcting for these by 1:1 matching, the mean chest tube drainage and rates of blood transfusion remained significantly lower (p transfused in TAR patients. By multivariate analysis, TAR had an independent effect on reducing blood transfusion after CABG [odds ratio (OR) 0.67, 95 % confidence interval (CI) 0.47-0.97, p = .03]. TAR achieved predominantly with left internal thoracic and radial arteries substantially reduced blood transfusion rates after primary CABG. Further studies are warranted.

  5. Radial electric fields for improved tokamak performance

    International Nuclear Information System (INIS)

    Downum, W.B.

    1981-01-01

    The influence of externally-imposed radial electric fields on the fusion energy output, energy multiplication, and alpha-particle ash build-up in a TFTR-sized, fusing tokamak plasma is explored. In an idealized tokamak plasma, an externally-imposed radial electric field leads to plasma rotation, but no charge current flows across the magnetic fields. However, a realistically-low neutral density profile generates a non-zero cross-field conductivity and the species dependence of this conductivity allows the electric field to selectively alter radial particle transport

  6. Radial MR images of the knee

    International Nuclear Information System (INIS)

    Hewes, R.C.; Miller, T.R.

    1988-01-01

    To profile optimally each portion of the meniscus, the authors use the multiangle, multisection feature of a General Electric SIGNA 1.5-T imager to produce radial images centered on each meniscus. A total of 12-15 sections are imaged at 10 0 -15 0 intervals of each meniscus, yielding perpendicular images of the entire meniscus, comparable with the arthrographic tangential views. The authors review their technique and demonstrate correlation cases between the radial gradient recalled acquisition in a steady state sequences, sagittal and coronal MR images, and arthrograms. Radial images should be a routine part of knee MR imaging

  7. Radial pattern of nuclear decay processes

    International Nuclear Information System (INIS)

    Iskra, W.; Mueller, M.; Rotter, I.; Technische Univ. Dresden

    1994-05-01

    At high level density of nuclear states, a separation of different time scales is observed (trapping effect). We calculate the radial profile of partial widths in the framework of the continuum shell model for some 1 - resonances with 2p-2h nuclear structure in 16 O as a function of the coupling strength to the continuum. A correlation between the lifetime of a nuclear state and the radial profile of the corresponding decay process is observed. We conclude from our numerical results that the trapping effect creates structures in space and time characterized by a small radial extension and a short lifetime. (orig.)

  8. Validation of a standardized mapping system of the hip joint for radial MRA sequencing

    International Nuclear Information System (INIS)

    Klenke, Frank M.; Hoffmann, Daniel B.; Cross, Brian J.; Siebenrock, Klaus A.

    2015-01-01

    Intraarticular gadolinium-enhanced magnetic resonance arthrography (MRA) is commonly applied to characterize morphological disorders of the hip. However, the reproducibility of retrieving anatomic landmarks on MRA scans and their correlation with intraarticular pathologies is unknown. A precise mapping system for the exact localization of hip pathomorphologies with radial MRA sequences is lacking. Therefore, the purpose of the study was the establishment and validation of a reproducible mapping system for radial sequences of hip MRA. Sixty-nine consecutive intraarticular gadolinium-enhanced hip MRAs were evaluated. Radial sequencing consisted of 14 cuts orientated along the axis of the femoral neck. Three orthopedic surgeons read the radial sequences independently. Each MRI was read twice with a minimum interval of 7 days from the first reading. The intra- and inter-observer reliability of the mapping procedure was determined. A clockwise system for hip MRA was established. The teardrop figure served to determine the 6 o'clock position of the acetabulum; the center of the greater trochanter served to determine the 12 o'clock position of the femoral head-neck junction. The intra- and inter-observer ICCs to retrieve the correct 6/12 o'clock positions were 0.906-0.996 and 0.978-0.988, respectively. The established mapping system for radial sequences of hip joint MRA is reproducible and easy to perform. (orig.)

  9. Arterial diameter during central volume depletion in humans

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg; Madsen, P; Matzen, S

    1995-01-01

    The luminal diameter of the radial artery was followed by high frequency ultrasound during 50 degrees head-up tilt-induced central volume depletion in ten healthy subjects of whom six were tilted twice and pretreated with the serotonin receptor antagonist methysergide or placebo following a double...

  10. Hepatic falciform artery

    International Nuclear Information System (INIS)

    Jaques, Paul F.; Mauro, Matthew A.; Sandhu, Jeet

    1997-01-01

    The hepatic falciform artery is an occasional terminal branch of the left or middle hepatic artery, and may provide an uncommon but important collateral route when the principal visceral arteries are occluded

  11. Evaluation of Transient Motion During Gadoxetic Acid-Enhanced Multiphasic Liver Magnetic Resonance Imaging Using Free-Breathing Golden-Angle Radial Sparse Parallel Magnetic Resonance Imaging.

    Science.gov (United States)

    Yoon, Jeong Hee; Lee, Jeong Min; Yu, Mi Hye; Hur, Bo Yun; Grimm, Robert; Block, Kai Tobias; Chandarana, Hersh; Kiefer, Berthold; Son, Yohan

    2018-01-01

    The aims of this study were to observe the pattern of transient motion after gadoxetic acid administration including incidence, onset, and duration, and to evaluate the clinical feasibility of free-breathing gadoxetic acid-enhanced liver magnetic resonance imaging using golden-angle radial sparse parallel (GRASP) imaging with respiratory gating. In this institutional review board-approved prospective study, 59 patients who provided informed consents were analyzed. Free-breathing dynamic T1-weighted images (T1WIs) were obtained using GRASP at 3 T after a standard dose of gadoxetic acid (0.025 mmol/kg) administration at a rate of 1 mL/s, and development of transient motion was monitored, which is defined as a distinctive respiratory frequency alteration of the self-gating MR signals. Early arterial, late arterial, and portal venous phases retrospectively reconstructed with and without respiratory gating and with different temporal resolutions (nongated 13.3-second, gated 13.3-second, gated 6-second T1WI) were evaluated for image quality and motion artifacts. Diagnostic performance in detecting focal liver lesions was compared among the 3 data sets. Transient motion (mean duration, 21.5 ± 13.0 seconds) was observed in 40.0% (23/59) of patients, 73.9% (17/23) of which developed within 15 seconds after gadoxetic acid administration. On late arterial phase, motion artifacts were significantly reduced on gated 13.3-second and 6-second T1WI (3.64 ± 0.34, 3.61 ± 0.36, respectively), compared with nongated 13.3-second T1WI (3.12 ± 0.51, P < 0.0001). Overall, image quality was the highest on gated 13.3-second T1WI (3.76 ± 0.39) followed by gated 6-second and nongated 13.3-second T1WI (3.39 ± 0.55, 2.57 ± 0.57, P < 0.0001). Only gated 6-second T1WI showed significantly higher detection performance than nongated 13.3-second T1WI (figure of merit, 0.69 [0.63-0.76]) vs 0.60 [0.56-0.65], P = 0.004). Transient motion developed in 40% (23/59) of patients shortly after

  12. String figures as mathematics? an anthropological approach to string figure-making in oral tradition societies

    CERN Document Server

    Vandendriessche, Eric

    2015-01-01

    This book addresses the mathematical rationality contained in the making of string figures. It does so by using interdisciplinary methods borrowed from anthropology, mathematics, history and philosophy of mathematics. The practice of string figure-making has long been carried out in many societies, and particularly in those of oral tradition. It consists in applying a succession of operations to a string (knotted into a loop), mostly using the fingers and sometimes the feet, the wrists or the mouth. This succession of operations is intended to generate a final figure. The book explores differ

  13. A case report of an isolated fracture through the radial bicipital tuberosity

    Directory of Open Access Journals (Sweden)

    Kanta Imao

    Full Text Available Introduction: Generally, anatomical reduction of shaft fractures through operative treatment is necessary to restore the anatomical relationship of the forearm bones. However, a number of nerves and vessels are located in the proximal radius, which complicates surgery. In this study, we aimed to reduce postoperative complications by using a posterior approach. Presentation of case: We describe an isolated fracture through the radial bicipital tuberosity in a 69-year-old man caused by direct blunt force and our management of the fracture. The patient underwent an operation for the fracture under brachial plexus block. The injury was explored using the posterior approach, and plate fixation was performed after confirming the absence of obstacles to rotation on pronation and supination. One year later, the patient did not have any difficulties in activities of daily living. Discussion: Since an isolated fracture through the radial bicipital tuberosity is more distal than the radial head and neck and more proximal than a common radius diaphysis fracture, we had to consider a different operative approach. The nerve and blood vessels of the forearm, such as the radial nerve and artery, run in a complicated fashion around the proximal radius; thus, we chose the posterior approach because of its simpler surgical technique and lower complication risk, compared with the anterior approach. Conclusion: Surgeons can obtain a favorable treatment result using the posterior approach to the fracture and reduce complications by ensuring with rigid fixation using a locking plate. Keywords: Radial bicipital tuberosity, Posterior approach, Posterior interosseous nerve, Shaft fracture

  14. STRESS FRACTURE PREVALENCE IN ELITE FIGURE SKATERS

    Directory of Open Access Journals (Sweden)

    Sanda Dubravcic-Simunjak

    2008-09-01

    Full Text Available Figure skating is a physically demanding sport that requires a unique combination of artistic ability, speed, agility, flexibility and power. During the last decades not only the competitive schedule has become tougher, but after introduction of the new judging system in 2003, also more emphasis is put on difficult technical elements, jumps, steps and spins (ISU Rules, 2006. More studies about possible increasing prevalence of stress fractures in figure skaters and contributing factors are lacking (Dubravcic-Simunjak et al., 2003; Moran, 2000; Pecina et al., 1990. Therefore the aim of this study was to obtain data about the current stress fracture cumulative risk among elite junior and senior figure skaters, as well as possible factors that may contribute to stress fracture incidence. An anonymous questionnaire, divided into 5 sections, inquired about the prevalence of stress fracture were mailed and distributed to all 62 International Skating Union (ISU members by the ISU headquarters in Lausanne, Switzerland. The guidelines of the Helsinki declaration 2004 were followed. From the 644 skaters who received the questionnaire, 412 completed ones were returned from 110 female juniors (78 single skaters, 12 pair skaters and 20 ice dancers and 135 female seniors (97 single skaters, 16 pair skaters and 22 ice dancers and from 79 male juniors (47 single skaters, 12 pair skaters and 20 ice dancers and 88 male seniors (50 single skaters, 16 pair skaters and 22 ice dancers, coming from different ISU members. The response rate was 62% in females and 67% in males. The median age for female skaters was 16 years and for males 18 years (range 12-25 years. All participants started to skate between 3 and 6 years of age and started to compete in national and international competitions when they were between 5 and 7 years old. At the time of this analysis, they had been skating between 9 and 20 years.In females 41 (16.7%, and in males 25 (13.8% figure skaters

  15. Radial contour labeling with straight leaders

    NARCIS (Netherlands)

    Niedermann, B.; Nöllenburg, M.; Rutter, I.

    2017-01-01

    The usefulness of technical drawings as well as scientific illustrations such as medical drawings of human anatomy essentially depends on the placement of labels that describe all relevant parts of the figure. In order to not spoil or clutter the figure with text, the labels are often placed around

  16. Radial transport with perturbed magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Hazeltine, R. D. [Institute for Fusion Studies, University of Texas at Austin, Austin, Texas 78712 (United States)

    2015-05-15

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order.

  17. Radial transport with perturbed magnetic field

    International Nuclear Information System (INIS)

    Hazeltine, R. D.

    2015-01-01

    It is pointed out that the viscosity coefficient describing radial transport of toroidal angular momentum is proportional to the second power of the gyro-radius—like the corresponding coefficients for particle and heat transport—regardless of any geometrical symmetry. The observation is widely appreciated, but worth emphasizing because some literature gives the misleading impression that asymmetry can allow radial moment transport in first-order

  18. Nuclear phaseout: a battle over figures

    International Nuclear Information System (INIS)

    Coloma, T.

    2012-01-01

    It is very difficult to assess the cost of abandoning nuclear energy in France because a lot of relevant figures are not published. The Court of Auditors is due to publish in 2012 a report of the costs of nuclear energy. In the case of nuclear phase out 2 costs have to be considered the dismantling cost and the cost of processing wastes and their disposal. As for the dismantling cost, official assessments in Great-Britain or Germany give a figure around 3 billions pounds per dismantled unit. In France the law imposes to EDF to put by 18 billions euros by 2016 for the future reactor dismantling. Concerning the cost of wastes, it could reach 35 billions euros for dealing with all the radioactive wastes produced till 2030. (A.C.)

  19. Energy in Sweden. Facts and figures 2004

    International Nuclear Information System (INIS)

    2004-12-01

    Energy in Sweden 2004: Facts and Figures contains the tabular data for most of the diagrams in the main publication. These data consist primarily of the results of the Agency's processing of basic data from Statistics Sweden. Facts and Figures is available at www.stem.se in pdf- and excel file formats. Since the year 2001 statistics for the period 1983-1998 are revised compared to data for previous editions. With effect from the 2001 edition, statistics are of preliminary character for the two preceding years. Breakdowns into certain types of fuels vary somewhat depending on whether preliminary or final data has been used. Further information about the statistics can be found in Energy in Sweden, chapter 8 Energy Facts.

  20. Figure and finish of grazing incidence mirrors

    International Nuclear Information System (INIS)

    Takacs, P.Z.; Church, E.L.

    1989-08-01

    Great improvement has been made in the past several years in the quality of optical components used in synchrotron radiation (SR) beamlines. Most of this progress has been the result of vastly improved metrology techniques and instrumentation permitting rapid and accurate measurement of the surface finish and figure on grazing incidence optics. A significant theoretical effort has linked the actual performance of components used as x-ray wavelengths to their topological properties as measured by surface profiling instruments. Next-generation advanced light sources will require optical components and systems to have sub-arc second surface figure tolerances. This paper will explore the consequences of these requirements in terms of manufacturing tolerances to see if the present manufacturing state-of-the-art is capable of producing the required surfaces. 15 refs., 14 figs., 2 tabs

  1. Figure correction of multilayer coated optics

    Science.gov (United States)

    Chapman; Henry N. , Taylor; John S.

    2010-02-16

    A process is provided for producing near-perfect optical surfaces, for EUV and soft-x-ray optics. The method involves polishing or otherwise figuring the multilayer coating that has been deposited on an optical substrate, in order to correct for errors in the figure of the substrate and coating. A method such as ion-beam milling is used to remove material from the multilayer coating by an amount that varies in a specified way across the substrate. The phase of the EUV light that is reflected from the multilayer will be affected by the amount of multilayer material removed, but this effect will be reduced by a factor of 1-n as compared with height variations of the substrate, where n is the average refractive index of the multilayer.

  2. Figuration of tourist personality and tourist travels

    Directory of Open Access Journals (Sweden)

    Đorđević Saša

    2013-01-01

    Full Text Available Quality of tourist travel is a relative category, because its success depends on the subjective perception of the personality of tourists on a tourist trip. For this reason, any tourist trip can be treated from the perspective of different types of figurative forms of tourists' personality, which also determine different quality of tourist travel, which, in turn, makes them different. Thus, any tourist trip, unto itself, has its own uniqueness, taking on the forms and content created, for the most part, by the tourists themselves, along with all other tourism stakeholders involved in this process. These forms and contents are primarily conditioned by the spiritual profile of tourists' personality and their psychological and motivational preferences, which is symbolically represented in the figurative context of a chess game. In addition to this, identification of essential characteristics of different spiritual profiles of tourist's personality, must be a starting point for the programming of overall content and especially of animation and cultural content.

  3. Variable-spot ion beam figuring

    International Nuclear Information System (INIS)

    Wu, Lixiang; Qiu, Keqiang; Fu, Shaojun

    2016-01-01

    This paper introduces a new scheme of ion beam figuring (IBF), or rather variable-spot IBF, which is conducted at a constant scanning velocity with variable-spot ion beam collimated by a variable diaphragm. It aims at improving the reachability and adaptation of the figuring process within the limits of machine dynamics by varying the ion beam spot size instead of the scanning velocity. In contrast to the dwell time algorithm in the conventional IBF, the variable-spot IBF adopts a new algorithm, which consists of the scan path programming and the trajectory optimization using pattern search. In this algorithm, instead of the dwell time, a new concept, integral etching time, is proposed to interpret the process of variable-spot IBF. We conducted simulations to verify its feasibility and practicality. The simulation results indicate the variable-spot IBF is a promising alternative to the conventional approach.

  4. Ambiguous Authorities: Vertigo and the Auteur Figure

    Directory of Open Access Journals (Sweden)

    Isabelle Licari-Guillaume

    2017-12-01

    Full Text Available This article examines authorial performance in the context of DC’s Vertigo line. In the 1990s, Vertigo gained its reputation as an innovative and progressive imprint by promoting the work of British scriptwriters, who were hailed as true author figures, despite the inherently collaborative nature of the mainstream comics industry. In a manner reminiscent of “auteur theory”, writers such as Neil Gaiman, Warren Ellis or Grant Morrison developed attractive author personas which they consistently displayed through interviews, letter columns or social media, but also, more importantly, by inserting their avatars within the comics they scripted. Upon closer examination, however, it becomes clear that their work in fact simultaneously asserts and destabilizes writerly authority, in a manner that is consistent with Linda Hutcheon’s view of postmodernity. By multiplying author figures and playfully disseminating authority, Vertigo authors question their own authorial control over the text, asserting instead the crucial role played by the reader.

  5. Perception of illusory contour figures: Microgenetic analysis

    OpenAIRE

    Gvozdenović Vasilije P.

    2004-01-01

    Microgenetic analysis was used to investigate perception of illusory contour figures which represent whole, completed forms on the basis of segmented, incomplete stimulation. The analysis provided an experimental approach to this phenomenon which was standardly investigated phenomenologically. Experimental procedure consisted of two phases: a) priming phase and b) test phase which consisted of visual search task. Two types of visual search tasks were applied: (i) classic detection, in which s...

  6. Omnichannel Marketing. Facts & Figures. Denmark 2017

    DEFF Research Database (Denmark)

    Futtrup Kjær, Jan; Kjær Jacobsen, Christine; Bjerre Herdel, Stine

    This NBI Omnichannel Facts and Figures report highlights the central findings from the NBI Omnichannel capability benchmarking tool, based on data collected in 2015 and 2016. The insights shared here provide an understanding of the way companies and marketing departments are working to deliver...... on - and adapt to - the challenges and opportunities related to the customer-centric, omnichannel experience. View this report as a data-freeze and analysis on the status of omnichannel in Denmark as of 2017....

  7. Stability of radial and non-radial pulsation modes of massive ZAMS models

    International Nuclear Information System (INIS)

    Odell, A.P.; Pausenwein, A.; Weiss, W.W.; Hajek, A.

    1987-01-01

    The authors have computed non-adiabatic eigenvalues for radial and non-radial pulsation modes of star models between 80 and 120 M solar with composition of chi=0.70 and Z=0.02. The radial fundamental mode is unstable in models with mass greater than 95 M solar , but the first overtone mode is always stable. The non-radial modes are all stable for all models, but the iota=2 f-mode is the closest to being driven. The non-radial modes are progressively more stable with higher iota and with higher n (for both rho- and g-modes). Thus, their results indicate that radial pulsation limits the upper mass of a star

  8. Coexistence of Single Coronary Artery Anomaly and Aortic Arch Anomaly

    Directory of Open Access Journals (Sweden)

    Yilmaz Omur Otlu

    2014-03-01

    Full Text Available A 74-year-old male patient was admitted to our hospital for evaluation of recent onset atypical chest pain. His medical history included hypertension, dislipidemia and smoking. Physical examination was unremarkable. The resting electrocardiogram was demonstrated biphasic T waves on lateral derivations. Transthoracic echocardiography showed normal left and right ventricular dimensions and functions. Coronary angiography was planned for the patient. First, right transradial approach tried; but guidewire could not be advanced to ascendig aorta. Coronary angiography was performed through the right femoral artery. Multiple attempts to cannulate the left coronary ostium were unsuccessful. The right coronary artery cannulated from its normal ostium in the right sinus of Valsalva. After a very short common main stem, the artery divided into a right coronary artery, and separate left anterior descending artery and circumflex artery (Figure A. The coronary arteries were normal without any significant stenosis and any extrinsic compression. An aortic root injection confirmed the absence of left coronary ostium. Also, a retroesophageal right subclavian artery originating from the left aortic arch (arteria lusoria was detected as the last branch of aortic arch on contrast enhanced computerized tomography (Figure B-C. The patient discharged with medical teraphy.

  9. Energy: facts and figures in 2006

    International Nuclear Information System (INIS)

    Lavergne, R.; Nanot, B.; Scherrer, S.; Paquel, V.; Louati, S.; Thienard, H.

    2007-01-01

    The consumption of final energy in France in 2006 increased slightly on the whole (+0.6%) and in all sectors except the industry (-0.7%). The final energy consumption is defined as the difference between the total consumption of primary energy and the consumption of the energy production sector. The evolution of the consumption of final energy is different according to the type of energy: +4.1% for coal (due to the strong demand in the iron and steel industry), +3.6% for renewable energies (due to specific development programs), +1.5% for electrical power and no change for oil and natural gas. Despite high prices, sales of car fuels rose by 0.4%, this figure hides the fact that the sales of fuels for diesel cars rose by 2.7% (because of the growing population of diesel cars) while those of grade petrol kept on plummeting (-5.9%). It is important to note that the releases of CO 2 due to energy went down by -1.4% in 2006. The energy bill increased by +18.5% to fetch 46.2*10 9 euros despite the decrease of the imported volumes. This articles details the energy figures for France in 2006 and sheds light particularly on 3 aspects: first, the annual trends in energy since 1973, secondly, the energy bill and thirdly the figures for electricity, natural gas, solid mineral fuels, hydrocarbons and renewable sources of energy. (A.C.)

  10. 21 CFR 866.4800 - Radial immunodiffusion plate.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4800 Radial immunodiffusion plate. (a) Identification. A radial immunodiffusion plate for clinical use...

  11. EXERCISE-INDUCED ARTERIAL ADAPTATIONS IN ELITE JUDO ATHLETES

    Directory of Open Access Journals (Sweden)

    Panagiotis Karagounis

    2009-09-01

    Full Text Available The purpose of this study was to examine exercise-induced arterial adaptations in elite Judo male and female athletes. 27 male Judo athletes (age 24.06 ± 2 years, 11 female Judoka (age 24.27 ± 1 years, 27 sedentary healthy men (age 24.01 ± 2 years and 11 women (age 24.21 ± 1 years participated in the current study. The examined vessels included brachial, radial, ulnar, popliteal, anterior and posterior tibial arteries. The experimental parameters were recorded with the use of Duplex ultrasound at rest. Diastolic diameter and blood mean flow velocity of the examined arteries in Judo athletes were found to be both significantly increased (p < 0.05 compared to the findings of the control groups. In male Judo athletes the brachial (p < 0.001, radial (p < 0.001, and anterior tibial artery (p < 0.001 presented the highest difference on the diastolic diameter, compared with the control male group. In female Judo athletes, ulnar (p < 0.001, radial (p < 0.001, and brachial (p < 0.001 arteries illustrated the highest diastolic diameter. The highest blood mean flow velocity was recorded in ulnar (p < 0.001 and popliteal arteries (p < 0.001 of the Judo athletes groups. Recording differences between the two genders, male participants presented larger arteries than females. Conclusively, Judo has been found to be a highly demanding physical sport, involving upper and lower limbs leading to significant arterial adaptations. Obtaining vascular parameters provide a useful tool to the medical team, not only in the direction of enhancement of the efficacy of physical training, but in unknown so far parameters that may influence athletic performance of both male and female elite Judokas

  12. An anatomical study of variations in termination of brachial artery, with its embryological basis and clinical significance

    Directory of Open Access Journals (Sweden)

    Deepa T. K

    2016-03-01

    Full Text Available The brachial artery is the main artery of the arm. It begins as the continuation of 3rd part of axillary artery, at the level of inferior border of teres major muscle. It ends at the level of the neck of radius by dividing into radial and ulnar arteries. In the present study we found higher division of brachial artery at mid arm level into its terminal branches with superficial course of radial artery. The present study was done on 51 cadavers from our dept. of Anatomy. The upper limbs of the cadaver were dissected and observed for any variations in the branching pattern of brachial artery. In the present study, a total number of 51 cadaver’s, 102 upper limbs were studied. In one male cadaver we found bilateral higher division of brachial artery, trifurcation on left side and bifurcation on right side brachial artery, with superficial course of radial artery. The knowledge of variation in origin and course of brachial artery is useful for orthopaedicians, physicians, radiologist, vascular and plastic surgeons.

  13. Figures and First Years: An Analysis of Calculus Students' Use of Figures in Technical Reports

    Directory of Open Access Journals (Sweden)

    Nathan J. Antonacci

    2017-07-01

    Full Text Available This three-year study focused on first-year Calculus I students and their abilities to incorporate figures in technical reports. In each year, these calculus students wrote a technical report as part of the Polar Bear Module, an educational unit developed for use in partner courses in biology, computer science, mathematics, and physics as part of the Multidisciplinary Sustainability Education (MSE project at Ithaca College. In the first year of the project, students received basic technical report guidelines. In year two, the report guidelines changed to include explicit language on how to incorporate figures. In year three, a grading rubric was added to the materials provided to one of the two classes. In all three years, the students performed below expectations in their use of graphs in their reports. Reviews of the figures in the 78 technical reports written by the 106 students showed repeated deficiencies in the figures and how the students used them in the discussion sections and in evidence-based arguments. In year three the student’s quantitative literacy (QL skills were assessed using an extract from a QL assessment instrument published in Numeracy. The results indicated that the students could both read and interpret figures, suggesting that issues with QL were not the main contributor to student difficulty with written discussion about graphs. The study underscores the need that explicit instructional attention be given to developing student knowhow in the use of figures in technical reports.

  14. Figurative Language on Maya Angelou selected Poetries

    Directory of Open Access Journals (Sweden)

    Risma Hayani

    2016-12-01

    Full Text Available This study aimed to find out the kinds of figurative language in the five selected poetries of Maya Angelou, the titles are: Alone, Caged Bird, Old Folks Laugh, Phenomenal Woman, Still I Rise. The focus of this study is figurative language which involves: Metaphor, Personification, Hyperbole, Simile, Metonymy, Synecdoche, Irony, Antithesis, Symbolism, and Paradox. Qualitative approach with design of content analysis was used in this study. The researcher acted as the main instrument since she was the one who analyzed the figurative language. Moreover checklist was also used to support her data collection. The data was analyzed through three stages; 1. Data reduction, 2. Data representation, 3. Conclusion. The result of her study showed there were 40 sentences that containing figurative language in five selected poetries of Maya Angelou. They were; Metaphor (13 sentences, Personification (9 sentences, Hyperbole (1 sentence, Simile (8 sentences, Synecdoche (1 sentence, Antithesis (1 sentence, Symbolism (5 sentences, and Paradox (2 sentences. The researcher conclude, if the figurative language used by Angelou to compare, or even symbolize the sentences to bring the meaning come up with beautiful language. Mostly of her poetries told about her experience in the past that rooted to history of the discrimination of American-African.

  15. Vascular patterns of upper limb: an anatomical study with accent on superficial brachial artery

    Directory of Open Access Journals (Sweden)

    David Kachlik

    2011-02-01

    Full Text Available The aim of the study was to evaluate the terminal segmentation of the axillary artery and to present four cases of anomalous branching of the axillary artery, the superficial brachial artery (arteria brachialis superficialis, which is defined as the brachial artery that runs superficially to the median nerve. Totally, 130 cadaveric upper arms embalmed by classical formaldehyde technique from collections of the Department of Anatomy, Third Faculty of Medicine, Charles University in Prague, were macroscopically dissected with special focus on the branching arrangement of the axillary artery. The most distal part of the axillary artery (infrapectoral part terminated in four cases as a bifurcation into two terminal branches: the superficial brachial artery and profunda brachii artery, denominated according to their relation to the median nerve. The profunda brachii artery primarily gave rise to the main branches of the infrapectoral part of the axillary artery. The superficial brachial artery descended to the cubital fossa where it assumed the usual course of the brachial artery in two cases and in the other two cases its branches (the radial and ulnar arteries passed superficially to the flexors. The incidence of the superficial brachial artery in our study was 5% of cases. The reported incidence is a bit contradictory, from 0.12% to 25% of cases. The anatomical knowledge of the axillary region is of crucial importance for neurosurgeons and specialists using the radiodiagnostic techniques, particularly in cases involving traumatic injuries. The improved knowledge would allow more accurate diagnostic interpretations and surgical treatment.

  16. Ion beam figuring of silicon aspheres

    Science.gov (United States)

    Demmler, Marcel; Zeuner, Michael; Luca, Alfonz; Dunger, Thoralf; Rost, Dirk; Kiontke, Sven; Krüger, Marcus

    2011-03-01

    Silicon lenses are widely used for infrared applications. Especially for portable devices the size and weight of the optical system are very important factors. The use of aspherical silicon lenses instead of spherical silicon lenses results in a significant reduction of weight and size. The manufacture of silicon lenses is more challenging than the manufacture of standard glass lenses. Typically conventional methods like diamond turning, grinding and polishing are used. However, due to the high hardness of silicon, diamond turning is very difficult and requires a lot of experience. To achieve surfaces of a high quality a polishing step is mandatory within the manufacturing process. Nevertheless, the required surface form accuracy cannot be achieved through the use of conventional polishing methods because of the unpredictable behavior of the polishing tools, which leads to an unstable removal rate. To overcome these disadvantages a method called Ion Beam Figuring can be used to manufacture silicon lenses with high surface form accuracies. The general advantage of the Ion Beam Figuring technology is a contactless polishing process without any aging effects of the tool. Due to this an excellent stability of the removal rate without any mechanical surface damage is achieved. The related physical process - called sputtering - can be applied to any material and is therefore also applicable to materials of high hardness like Silicon (SiC, WC). The process is realized through the commercially available ion beam figuring system IonScan 3D. During the process, the substrate is moved in front of a focused broad ion beam. The local milling rate is controlled via a modulated velocity profile, which is calculated specifically for each surface topology in order to mill the material at the associated positions to the target geometry. The authors will present aspherical silicon lenses with very high surface form accuracies compared to conventionally manufactured lenses.

  17. Equilibrium figures for beta Lyrae type disks

    International Nuclear Information System (INIS)

    Wilson, R.E.

    1981-01-01

    Accumulated evidence for a geometrically and optically thick disk in the β Lyrae system has now established the disk's basic external configuration. Since the disk has been constant in its main properties over the historical interval of β Lyrae observations and also seems to have a basically well-defined photosphere, it is now time to being consideration of its sturcture. Here, we compute equilibrium figures for self-gravitating disks around stars in binary systems as a start toward eventual computation of complete disk models. A key role is played by centrifugally limited rotation of the central star, which would naturally arise late in the rapid phase of mass transfer. Beta Lyrae is thus postulated to be a double-contact binary, which makes possible nonarbitrary separation of star and disk into separate structures. The computed equilibrium figures are three-dimensional, as the gravitation of the second star is included. Under the approximation that the gravitational potential of the disk is that of a thin wire and that the local disk angular velocity is proportional to u/sup n/ (u = distance from rotation axis), we comptue the total potential and locate equipotential surfaces. The centrifugal potential is written in a particularly convenient form which permits one to change the rotation law discontinuously (for example, at the star-disk coupling point) while ensuring that centrifugal potential and centrifigual force are continuous functions of position. With such a one-parameter rotation law, one can find equilibrium disk figures with dimensions very similar to those found in β Lyrae, but considerations of internal consistency demand at least a two-parameter law

  18. Noise figure of amplified dispersive Fourier transformation

    International Nuclear Information System (INIS)

    Goda, Keisuke; Jalali, Bahram

    2010-01-01

    Amplified dispersive Fourier transformation (ADFT) is a powerful tool for fast real-time spectroscopy as it overcomes the limitations of traditional optical spectrometers. ADFT maps the spectrum of an optical pulse into a temporal waveform using group-velocity dispersion and simultaneously amplifies it in the optical domain. It greatly simplifies spectroscopy by replacing the diffraction grating and detector array in the conventional spectrometer with a dispersive fiber and single-pixel photodetector, enabling ultrafast real-time spectroscopic measurements. Following our earlier work on the theory of ADFT, here we study the effect of noise on ADFT. We derive the noise figure of ADFT and discuss its dependence on various parameters.

  19. Theories of figures of celestial bodies

    CERN Document Server

    Jardetzky, Wenceslas S

    2005-01-01

    Everything in the universe rotates: the meteors, the asteroids, the planets and their satellites, the sun, the stars, the clusters and nebulae, even the galaxies themselves. The problem of the shape of a rotating body is therefore universal in astronomy. Its treatment in this book, which deals with the figures of equilibrium and distortions of rotating bodies, is full and rigorous.Suitable for upper-level undergraduates and graduate students, this text was written by a renowned researcher and educator who taught at Columbia University and served for many years as a research associate at the La

  20. Children's Drawing of Human Figure Analisis

    Directory of Open Access Journals (Sweden)

    Salko Pezo

    2011-08-01

    Full Text Available Beside speech, that helps children to express their feelings and experiences, establish relations with people, the drawing is one of the most truthful ways of its expression. In this paper the results of pleasant and unpleasant emo­tions among children through drawing of human figure are presented. The survey is conducted on 634 children, and the results indicate that there is difference in expressing negative emotions between boys and girls, while at expressing pleasant emotions the results are similar.

  1. Distinguished figures in mechanism and machine science

    CERN Document Server

    2014-01-01

    This book is composed of chapters that focus specifically on technological developments by distinguished figures in the history of MMS (Mechanism and Machine Science).  Biographies of well-known scientists are also included to describe their efforts and experiences, and surveys of their work and achievements, and a modern interpretation of their legacy are presented. After the first two volumes, the papers in this third volume again cover a wide range within the field of the History of Mechanical Engineering with specific focus on MMS and will be of interest and motivation to the work (historical or not) of many.

  2. Emotional indicators in children's human figure drawings.

    Science.gov (United States)

    Catte, M; Cox, M V

    1999-06-01

    The human figure drawings of a group of emotionally-disturbed boys were compared with those of a group of well-adjusted boys closely matched for chronological age and another for mental age. A comparison based on Koppitz's (1968) original emotional indicators and another, based on new UK norms, showed that the emotionally-disturbed children included significantly more indicators in their drawings than their well-adjusted peers. Although this difference was statistically significant it is actually quite small. In addition, there were no differences among the groups in the kinds of indicators they exhibited. The usefulness of the Koppitz test as a tool for clinical use is questioned.

  3. Exogenous spatial attention influences figure-ground assignment.

    Science.gov (United States)

    Vecera, Shaun P; Flevaris, Anastasia V; Filapek, Joseph C

    2004-01-01

    In a hierarchical stage account of vision, figure-ground assignment is thought to be completed before the operation of focal spatial attention. Results of previous studies have supported this account by showing that unpredictive, exogenous spatial precues do not influence figure-ground assignment, although voluntary attention can influence figure-ground assignment. However, in these studies, attention was not summoned directly to a region in a figure-ground display. In three experiments, we addressed the relationship between figure-ground assignment and visuospatial attention. In Experiment 1, we replicated the finding that exogenous precues do not influence figure-ground assignment when they direct attention outside of a figure-ground stimulus. In Experiment 2, we demonstrated that exogenous attention can influence figure-ground assignment if it is directed to one of the regions in a figure-ground stimulus. In Experiment 3, we demonstrated that exogenous attention can influence figure-ground assignment in displays that contain a Gestalt figure-ground cue; this result suggests that figure-ground processes are not entirely completed prior to the operation of focal spatial attention. Exogenous spatial attention acts as a cue for figure-ground assignment and can affect the outcome of figure-ground processes.

  4. Figures in clinical trial reports: current practice & scope for improvement.

    Science.gov (United States)

    Pocock, Stuart J; Travison, Thomas G; Wruck, Lisa M

    2007-11-19

    Most clinical trial publications include figures, but there is little guidance on what results should be displayed as figures and how. To evaluate the current use of figures in Trial reports, and to make constructive suggestions for future practice. We surveyed all 77 reports of randomised controlled trials in five general medical journals during November 2006 to January 2007. The numbers and types of figures were determined, and then each Figure was assessed for its style, content, clarity and suitability. As a consequence, guidelines are developed for presenting figures, both in general and for each specific common type of Figure. Most trial reports contained one to three figures, mean 2.3 per article. The four main types were flow diagram, Kaplan Meier plot, Forest plot (for subgroup analyses) and repeated measures over time: these accounted for 92% of all figures published. For each type of figure there is a considerable diversity of practice in both style and content which we illustrate with selected examples of both good and bad practice. Some pointers on what to do, and what to avoid, are derived from our critical evaluation of these articles' use of figures. There is considerable scope for authors to improve their use of figures in clinical trial reports, as regards which figures to choose, their style of presentation and labelling, and their specific content. Particular improvements are needed for the four main types of figures commonly used.

  5. Figures in clinical trial reports: current practice & scope for improvement

    Directory of Open Access Journals (Sweden)

    Travison Thomas G

    2007-11-01

    Full Text Available Abstract Background Most clinical trial publications include figures, but there is little guidance on what results should be displayed as figures and how. Purpose To evaluate the current use of figures in Trial reports, and to make constructive suggestions for future practice. Methods We surveyed all 77 reports of randomised controlled trials in five general medical journals during November 2006 to January 2007. The numbers and types of figures were determined, and then each Figure was assessed for its style, content, clarity and suitability. As a consequence, guidelines are developed for presenting figures, both in general and for each specific common type of Figure. Results Most trial reports contained one to three figures, mean 2.3 per article. The four main types were flow diagram, Kaplan Meier plot, Forest plot (for subgroup analyses and repeated measures over time: these accounted for 92% of all figures published. For each type of figure there is a considerable diversity of practice in both style and content which we illustrate with selected examples of both good and bad practice. Some pointers on what to do, and what to avoid, are derived from our critical evaluation of these articles' use of figures. Conclusion There is considerable scope for authors to improve their use of figures in clinical trial reports, as regards which figures to choose, their style of presentation and labelling, and their specific content. Particular improvements are needed for the four main types of figures commonly used.

  6. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  7. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2014-07-01

    Full Text Available Background: The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. Objective: To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. Methods: From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. Results: The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. Conclusions: The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  8. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    International Nuclear Information System (INIS)

    Andrade, Pedro Beraldo de; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André; Hernandes, Mauro Esteves; Marino, Roberto Luiz; Precoma, Dalton Bertolim; Sá, Francisco Carleial Feijó de; Berwanger, Otávio; Mattos, Luiz Alberto Piva e

    2014-01-01

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques

  9. Femoral versus Radial Access in Primary Angioplasty. Analysis of the ACCEPT Registry

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Pedro Beraldo de, E-mail: pedroberaldo@cardiol.br; Andrade, Mônica Vieira Athanazio de; Barbosa, Robson Alves; Labrunie, André [Santa Casa de Misericórdia de Marília, São Paulo -SP (Brazil); Hernandes, Mauro Esteves [Santa Casa de Votuporanga, São Paulo -SP (Brazil); Marino, Roberto Luiz [Hospital Madre Teresa, Belo Horizonte -MG (Brazil); Precoma, Dalton Bertolim [Sociedade Hospital Angelina Caron, Campina Grande do Sul -PR (Brazil); Sá, Francisco Carleial Feijó de [Hospital do Coração do Cariri, Barbalha -CE (Brazil); Berwanger, Otávio [Instituto de Ensino e Pesquisa do Hospital do Coração, São Paulo -SP (Brazil); Mattos, Luiz Alberto Piva e [Sociedade Brasileira de Cardiologia, São Paulo -SP (Brazil); Instituto Dante Pazzanese de Cardiologia, São Paulo -SP (Brazil); Unidades de Hemodinâmica e Intervenção Cardiovascular Rede D' Or / São Luiz, São Paulo, SP (Brazil)

    2014-06-15

    The radial access provides a lower risk of bleeding and vascular complications related to the puncture site in comparison to the femoral access. Recent studies have suggested a reduction in mortality associated with the radial access in patients with acute myocardial infarction undergoing percutaneous coronary intervention. To compare the occurrence of adverse cardiovascular ischemic and hemorrhagic events in patients undergoing primary angioplasty according to the type of arterial access route. From August 2010 to December 2011, 588 patients undergoing primary percutaneous coronary intervention during acute ST-segment elevation myocardial infarction were assessed; they were recruited from 47 centers participating in the ACCEPT registry. Patients were grouped and compared according to the arterial access used for the procedure. The mean age was 61.8 years; 75% were males and 24% had diabetes mellitus. There was no difference between groups as regards the procedure success rate, as well as regards the occurrence of death, reinfarction, or stroke at six months of follow-up. Severe bleeding was reported in 1.1% of the sample analyzed, with no statistical difference related to the access used. The femoral and radial accesses are equally safe and effective for the performance of primary percutaneous coronary intervention. The low rate of cardiovascular events and of hemorrhagic complications reflects the quality of the participating centers and the operators expertise with the use of both techniques.

  10. Physical mechanism determining the radial electric field and its radial structure in a toroidal plasma

    International Nuclear Information System (INIS)

    Ida, Katsumi; Miura, Yukitoshi; Itoh, Sanae

    1994-10-01

    Radial structures of plasma rotation and radial electric field are experimentally studied in tokamak, heliotron/torsatron and stellarator devices. The perpendicular and parallel viscosities are measured. The parallel viscosity, which is dominant in determining the toroidal velocity in heliotron/torsatron and stellarator devices, is found to be neoclassical. On the other hand, the perpendicular viscosity, which is dominant in dictating the toroidal rotation in tokamaks, is anomalous. Even without external momentum input, both a plasma rotation and a radial electric field exist in tokamaks and heliotrons/torsatrons. The observed profiles of the radial electric field do not agree with the theoretical prediction based on neoclassical transport. This is mainly due to the existence of anomalous perpendicular viscosity. The shear of the radial electric field improves particle and heat transport both in bulk and edge plasma regimes of tokamaks. (author) 95 refs

  11. Manufacturing of Precision Forgings by Radial Forging

    International Nuclear Information System (INIS)

    Wallner, S.; Harrer, O.; Buchmayr, B.; Hofer, F.

    2011-01-01

    Radial forging is a multi purpose incremental forging process using four tools on the same plane. It is widely used for the forming of tool steels, super alloys as well as titanium- and refractory metals. The range of application goes from reducing the diameters of shafts, tubes, stepped shafts and axels, as well as for creating internal profiles for tubes in Near-Net-Shape and Net-Shape quality. Based on actual development of a weight optimized transmission input shaft, the specific features of radial forging technology is demonstrated. Also a Finite Element Model for the simulation of the process is shown which leads to reduced pre-processing effort and reduced computing time compared to other published simulation methods for radial forging. The finite element model can be applied to quantify the effects of different forging strategies.

  12. Deficit in figure-ground segmentation following closed head injury.

    Science.gov (United States)

    Baylis, G C; Baylis, L L

    1997-08-01

    Patient CB showed a severe impairment in figure-ground segmentation following a closed head injury. Unlike normal subjects, CB was unable to parse smaller and brighter parts of stimuli as figure. Moreover, she did not show the normal effect that symmetrical regions are seen as figure, although she was able to make overt judgments of symmetry. Since she was able to attend normally to isolated objects, CB demonstrates a dissociation between figure ground segmentation and subsequent processes of attention. Despite her severe impairment in figure-ground segmentation, CB showed normal 'parallel' single feature visual search. This suggests that figure-ground segmentation is dissociable from 'preattentive' processes such as visual search.

  13. Perception of illusory contour figures: Microgenetic analysis

    Directory of Open Access Journals (Sweden)

    Gvozdenović Vasilije P.

    2004-01-01

    Full Text Available Microgenetic analysis was used to investigate perception of illusory contour figures which represent whole, completed forms on the basis of segmented, incomplete stimulation. The analysis provided an experimental approach to this phenomenon which was standardly investigated phenomenologically. Experimental procedure consisted of two phases: a priming phase and b test phase which consisted of visual search task. Two types of visual search tasks were applied: (i classic detection, in which subjects were detecting presence or absence of the target stimuli and (ii two-alternative forced choice, 2AFC, in which subjects performed discrimination between two concurrent targets (target A vs. target B. Variation of exposition of prim stimuli was used as an indication of the percept formation period. Concepts like early vision, visual attention and feature binding were investigated. Four experiments were conducted. Their outcome showed that (i perception of amodal figure requires visual attention, (ii features binding precedes spatial attention and (iii time period of percept formation is dependent of task properties and varies between 50 - 150 ms. Some results obtained in this research could be explained by feature-integration theory (Treisman & Gelade, 1980; Treisman, 1986. Furthermore, percept formation period data comply with data acquired in Elliott & Müller's psychophysical research (1998.

  14. The Matlab Radial Basis Function Toolbox

    Directory of Open Access Journals (Sweden)

    Scott A. Sarra

    2017-03-01

    Full Text Available Radial Basis Function (RBF methods are important tools for scattered data interpolation and for the solution of Partial Differential Equations in complexly shaped domains. The most straight forward approach used to evaluate the methods involves solving a linear system which is typically poorly conditioned. The Matlab Radial Basis Function toolbox features a regularization method for the ill-conditioned system, extended precision floating point arithmetic, and symmetry exploitation for the purpose of reducing flop counts of the associated numerical linear algebra algorithms.

  15. Radial velocity observations of VB10

    Science.gov (United States)

    Deshpande, R.; Martin, E.; Zapatero Osorio, M. R.; Del Burgo, C.; Rodler, F.; Montgomery, M. M.

    2011-07-01

    VB 10 is the smallest star known to harbor a planet according to the recent astrometric study of Pravdo & Shaklan [1]. Here we present near-infrared (J-band) radial velocity of VB 10 performed from high resolution (R~20,000) spectroscopy (NIRSPEC/KECK II). Our results [2] suggest radial velocity variability with amplitude of ~1 km/s, a result that is consistent with the presence of a massive planet companion around VB10 as found via long-term astrometric monitoring of the star by Pravdo & Shaklan. Employing an entirely different technique we verify the results of Pravdo & Shaklan.

  16. Plasma Signatures of Radial Field Power Dropouts

    International Nuclear Information System (INIS)

    Lucek, E.A.; Horbury, T.S.; Balogh, A.; McComas, D.J.

    1998-01-01

    A class of small scale structures, with a near-radial magnetic field and a drop in magnetic field fluctuation power, have recently been identified in the polar solar wind. An earlier study of 24 events, each lasting for 6 hours or more, identified no clear plasma signature. In an extension of that work, radial intervals lasting for 4 hours or more (89 in total), have been used to search for a statistically significant plasma signature. It was found that, despite considerable variations between intervals, there was a small but significant drop, on average, in plasma temperature, density and β during these events

  17. Reble, a radially converging electron beam accelerator

    International Nuclear Information System (INIS)

    Ramirez, J.J.; Prestwich, K.R.

    1976-01-01

    The Reble accelerator at Sandia Laboratories is described. This accelerator was developed to provide an experimental source for studying the relevant diode physics, beam propagation, beam energy deposition in a gas using a radially converging e-beam. The nominal parameters for Reble are 1 MV, 200 kA, 20 ns e-beam pulse. The anode and cathode are concentric cylinders with the anode as the inner cylinder. The radial beam can be propagated through the thin foil anode into the laser gas volume. The design and performance of the various components of the accelerator are presented

  18. The phosphodiesterase 3 inhibitor cilostazol dilates large cerebral arteries in humans without affecting regional cerebral blood flow

    DEFF Research Database (Denmark)

    Birk, Steffen; Kruuse, Christina Rostrup; Petersen, Kenneth A

    2004-01-01

    in the middle cerebral arteries (VMCA) was measured with transcranial Doppler, and the superficial temporal and radial arteries diameters were measured with ultrasonography. During the 4-hour observation period, there was no effect on systolic blood pressure (P = 0.28), but diastolic blood pressure decreased...

  19. Karna Particle Size Dataset for Tables and Figures

    Data.gov (United States)

    U.S. Environmental Protection Agency — This dataset contains 1) table of bulk Pb-XAS LCF results, 2) table of bulk As-XAS LCF results, 3) figure data of particle size distribution, and 4) figure data for...

  20. Advancing Sustainable Materials Management: Facts and Figures Report

    Science.gov (United States)

    Each year EPA releases the Advancing Sustainable Materials Management: Facts and Figures report, formerly called Municipal Solid Waste in the United States: Facts and Figures. It includes information on Municipal Solid Waste generation, recycling, an

  1. Figure-ground mechanisms provide structure for selective attention.

    Science.gov (United States)

    Qiu, Fangtu T; Sugihara, Tadashi; von der Heydt, Rüdiger

    2007-11-01

    Attention depends on figure-ground organization: figures draw attention, whereas shapes of the ground tend to be ignored. Recent research has revealed mechanisms for figure-ground organization in the visual cortex, but how these mechanisms relate to the attention process remains unclear. Here we show that the influences of figure-ground organization and volitional (top-down) attention converge in single neurons of area V2 in Macaca mulatta. Although we found assignment of border ownership for attended and for ignored figures, attentional modulation was stronger when the attended figure was located on the neuron's preferred side of border ownership. When the border between two overlapping figures was placed in the receptive field, responses depended on the side of attention, and enhancement was generally found on the neuron's preferred side of border ownership. This correlation suggests that the neural network that creates figure-ground organization also provides the interface for the top-down selection process.

  2. Small arteries can be accurately studied in vivo, using high frequency ultrasound

    DEFF Research Database (Denmark)

    Nielsen, T H; Iversen, Helle Klingenberg; Tfelt-Hansen, P

    1993-01-01

    We have validated measurements of diameters of the superficial temporal artery and other small arteries in man with a newly developed 20 MHz ultrasound scanner with A, B and M-mode imaging. The diameter of a reference object was 1.202 mm vs. 1.205 mm as measured by stereomicroscopy (nonsignifican......-gauge plethysmography (nonsignificant). Pulsations were 4.6% in the radial artery. We conclude that high frequency ultrasound provides an accurate and reproducible measure of the diameter of small and medium sized human arteries in vivo....

  3. Figure-ground mechanisms provide structure for selective attention

    OpenAIRE

    Qiu, Fangtu T.; Sugihara, Tadashi; von der Heydt, Rüdiger

    2007-01-01

    Attention depends on figure-ground organization: figures draw attention, while shapes of the ground tend to be ignored. Recent research has demonstrated mechanisms of figure-ground organization in the visual cortex, but how they relate to the attention process remains unclear. Here we show that the influences of figure-ground organization and volitional (top-down) attention converge in single neurons of area V2. While assignment of border ownership was found for attended as well as for ignore...

  4. Figures on public utilities, 1976/77

    Energy Technology Data Exchange (ETDEWEB)

    1979-09-01

    Qualified statistical data belong to the instruments of effective association work. Therefore the association, among other activities, carries out statistical investigations on business management among its member enterprises at intervals of two years. This volume contains the results of the business years 1976 and 1977. A main purpose of this statistics is to offer guidelines to the member enterprises, especially figures which allow to compare the evaluated average values of the business with data of the own enterprise, which may be, if necessary, an impetus to think about measures of rationalization. As in former statistics all the results are classified in seven categories that are determined by the size of the enterprise. Compared with the last questionnaire some items have been altered to facilitate the completion. Questions concerning the extent of the public utilities, the structure of the network system and investment planning have been introduced for the first time.

  5. FIGUR WANITA SEBAGAI PENARIK PANDANG DALAM IKLAN

    Directory of Open Access Journals (Sweden)

    Andrian D. Hagijanto

    2000-01-01

    Full Text Available In order to gain brand awareness effectively%2C advertiser use unusual and sometimes inappropriate form of creatifity to make their ads more memorable such method includes the use of women s sexual attractions which%2C on the other hand%2C causes in fraction of ethical norms. Will this be called a deviations in ads or a compromise approach to the audience taste? Abstract in Bahasa Indonesia : Untuk mencapai brand awareness yang lebih tinggi%2C pengiklan harus membuat iklannya menarik%2C lewat kreativitas yang tinggi. Ketika kreativitas itu menggunakan pendekatan yang terjebak oleh pelanggaran norma-norma etis kemasyarakatan -lewat eksploatasi figur wanita dan daya tarik yang melingkupinya-. Akankah kreativitas itu disebut sebagai penyimpangan dalam iklan? Ataukah sah-sah saja sebagai suatu bentuk pendekatan yang menuruti selera pasar. advertisement%2C women s sexual attractions%2C body language

  6. Who's bigger? where historical figures really rank

    CERN Document Server

    Skiena, Steven

    2014-01-01

    Is Hitler bigger than Napoleon? Washington bigger than Lincoln? Picasso bigger than Einstein? Quantitative analysts are rapidly finding homes in social and cultural domains, from finance to politics. What about history? In this fascinating book, Steve Skiena and Charles Ward bring quantitative analysis to bear on ranking and comparing historical reputations. They evaluate each person by aggregating the traces of millions of opinions, just as Google ranks webpages. The book includes a technical discussion for readers interested in the details of the methods, but no mathematical or computational background is necessary to understand the rankings or conclusions. Along the way, the authors present the rankings of more than one thousand of history's most significant people in science, politics, entertainment, and all areas of human endeavor. Anyone interested in history or biography can see where their favorite figures place in the grand scheme of things.

  7. On helicon wave induced radial plasma transport

    International Nuclear Information System (INIS)

    Petrzilka, V.

    1993-04-01

    Estimates of helicon wave induced radial plasma transport are presented. The wave induced transport grows or decreases in dependence on the sign of the azimuthal wave number; these changes in transport may play an important role in helicon wave plasma sources. (author) 5 figs., 18 refs

  8. Revealing the radial modes in vortex beams

    CSIR Research Space (South Africa)

    Sephton, Bereneice C

    2016-10-01

    Full Text Available Light beams that carry orbital angular momentum are often approximated by modulating an initial beam, usually Gaussian, with an azimuthal phase variation to create a vortex beam. Such vortex beams are well defined azimuthally, but the radial profile...

  9. Measurement of Wear in Radial Journal Bearings

    NARCIS (Netherlands)

    Ligterink, D.J.; Ligterink, D.J.; de Gee, A.W.J.

    1996-01-01

    this article, the measurement of wear in radial journal bearings is discussed, where a distinction is made between stationary and non-stationary contact conditions. Starting with Holm/Archard's wear law, equations are derived for the calculation of the specific wear rate k of the bearing material as

  10. Radial interchange motions of plasma filaments

    DEFF Research Database (Denmark)

    Garcia, O.E.; Bian, N.H.; Fundamenski, W.

    2006-01-01

    on a biperiodic domain perpendicular to the magnetic field. It is demonstrated that a blob-like plasma structure develops dipolar vorticity and electrostatic potential fields, resulting in rapid radial acceleration and formation of a steep front and a trailing wake. While the dynamical evolution strongly depends...

  11. Radial transfer effects for poloidal rotation

    Science.gov (United States)

    Hallatschek, Klaus

    2010-11-01

    Radial transfer of energy or momentum is the principal agent responsible for radial structures of Geodesic Acoustic Modes (GAMs) or stationary Zonal Flows (ZF) generated by the turbulence. For the GAM, following a physical approach, it is possible to find useful expressions for the individual components of the Poynting flux or radial group velocity allowing predictions where a mathematical full analysis is unfeasible. Striking differences between up-down symmetric flux surfaces and asymmetric ones have been found. For divertor geometries, e.g., the direction of the propagation depends on the sign of the ion grad-B drift with respect to the X-point, reminiscent of a sensitive determinant of the H-mode threshold. In nonlocal turbulence computations it becomes obvious that the linear energy transfer terms can be completely overwhelmed by the action of the turbulence. In contrast, stationary ZFs are governed by the turbulent radial transfer of momentum. For sufficiently large systems, the Reynolds stress becomes a deterministic functional of the flows, which can be empirically determined from the stress response in computational turbulence studies. The functional allows predictions even on flow/turbulence states not readily obtainable from small amplitude noise, such as certain transport bifurcations or meta-stable states.

  12. Spectral problem for the radial Schroedinger equation

    International Nuclear Information System (INIS)

    Vshivtsev, A.S.; Tatarintsev, A.V.; Prokopov, A.V.; Sorokin, V. N.

    1998-01-01

    For the first time, a procedure for determining spectra on the basis of generalized integral transformations is implemented for a wide class of radial Schroedinger equations. It is shown that this procedure works well for known types of potentials. Concurrently, this method makes it possible to obtain new analytic results for the Cornell potential. This may prove important for hadron physics

  13. Computing modal dispersion characteristics of radially Asymmetric ...

    African Journals Online (AJOL)

    We developed a matrix theory that applies to with non-circular/circular but concentric layers fibers. And we compute the dispersion characteristics of radially unconventional fiber, known as Asymmetric Bragg fiber. An attempt has been made to determine how the modal characteristics change as circular Bragg fiber is ...

  14. Figures in Space, Figuring Space: Towards a Spatialsymbolic Framework for Understanding Youth Cultures and Identities

    DEFF Research Database (Denmark)

    Ravn, Signe; Demant, Jakob Johan

    2017-01-01

    (n = 80) in four different parts of Denmark. The interviews included a photo elicitation exercise and the analysis in this article focuses on one particular picture of two young ‘hipster’ men. By using the figure of the hipster as an analytical case, the article illustrates how individual and spatial...... of paying attention to structural inequalities....

  15. Figure Structure, Figure Action, and Framing in Drawings by American and Egyptian Children.

    Science.gov (United States)

    Wilson, Brent; Wilson, Marjorie

    1979-01-01

    The purpose of this study is to investigate the interaction of biological unfolding and culturally related factors on sequences of narrative figure drawings by American and Egyptian elementary students. Findings support hypotheses relating to the interaction of natural and nurtural influences on children's drawings. (Author/SJL)

  16. Figure 1. T. tor species. Figure 2. Long PCR products of ...

    Indian Academy of Sciences (India)

    Annam

    Figure 2. Long PCR products of mitochondrial DNA from the fish T. tor. Lane 1, amplified product using L-12321-Leu and S-LA-16S-H primers. Lane 2, amplified product using H-12321 –Leu and S-LA-16S-L primers. Lane M, 1-Kb DNA ladder. 8 kb ...

  17. Radial wave crystals: radially periodic structures from anisotropic metamaterials for engineering acoustic or electromagnetic waves.

    Science.gov (United States)

    Torrent, Daniel; Sánchez-Dehesa, José

    2009-08-07

    We demonstrate that metamaterials with anisotropic properties can be used to develop a new class of periodic structures that has been named radial wave crystals. They can be sonic or photonic, and wave propagation along the radial directions is obtained through Bloch states like in usual sonic or photonic crystals. The band structure of the proposed structures can be tailored in a large amount to get exciting novel wave phenomena. For example, it is shown that acoustical cavities based on radial sonic crystals can be employed as passive devices for beam forming or dynamically orientated antennas for sound localization.

  18. Current density and polarization curves for radial flow field patterns applied to PEMFCs (Proton Exchange Membrane Fuel Cells)

    International Nuclear Information System (INIS)

    Cano-Andrade, S.; Hernandez-Guerrero, A.; Spakovsky, M.R. von; Damian-Ascencio, C.E.; Rubio-Arana, J.C.

    2010-01-01

    A numerical solution of the current density and velocity fields of a 3-D PEM radial configuration fuel cell is presented. The energy, momentum and electrochemical equations are solved using a computational fluid dynamics (CFD) code based on a finite volume scheme. There are three cases of principal interest for this radial model: four channels, eight channels and twelve channels placed in a symmetrical path over the flow field plate. The figures for the current-voltage curves for the three models proposed are presented, and the main factors that affect the behavior of each of the curves are discussed. Velocity contours are presented for the three different models, showing how the fuel cell behavior is affected by the velocity variations in the radial configuration. All these results are presented for the case of high relative humidity. The favorable results obtained for this unconventional geometry seems to indicate that this geometry could replace the conventional commercial geometries currently in use.

  19. Understanding the requirements of self-expandable stents for heart valve replacement: Radial force, hoop force and equilibrium.

    Science.gov (United States)

    Cabrera, María Sol; Oomens, Cees W J; Baaijens, Frank P T

    2017-04-01

    A proper interpretation of the forces developed during stent crimping and deployment is of paramount importance for a better understanding of the requirements for successful heart valve replacement. The present study combines experimental and computational methods to assess the performance of a nitinol stent for tissue-engineered heart valve implantation. To validate the stent model, the mechanical response to parallel plate compression and radial crimping was evaluated experimentally. Finite element simulations showed good agreement with the experimental findings. The computational models were further used to determine the hoop force on the stent and radial force on a rigid tool during crimping and self-expansion. In addition, stent deployment against ovine and human pulmonary arteries was simulated to determine the hoop force on the stent-artery system and the equilibrium diameter for different degrees of oversizing. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Single Center Retrospective Analysis of Conventional and Radial TIG Catheters for Transradial Diagnostic Coronary Angiography.

    Science.gov (United States)

    Vorpahl, Marc; Koehler, Till; Foerst, Jason; Panagiotopoulos, Spyridon; Schleiting, Heinrich; Koss, Klaus; Ziegler, Gunda; Brinkmann, Hilmar; Seyfarth, Melchior; Tiroch, Klaus

    2015-01-01

    Current guidelines favor the radial approach for coronary angiography. Therefore, specialty radial diagnostic catheters were designed to engage both coronary arteries with a single device. However, it is unclear if single catheters are superior to conventional catheters. A retrospective analysis was performed of consecutive right radial coronary angiographies to determine catheter use, fluoroscopy time, radiation dosage, and consumption of contrast. Procedures were performed with a single TIG catheter or conventional catheters (CONV). Procedures with coronary artery bypass grafts or ventricular angiographies were excluded. 273 transradial procedures were performed successfully. 95 procedures were performed with CONV and 178 procedures with a TIG. Crossover to additional catheters was higher in TIG (15.2%) compared to CONV (5.3%, p = 0.02). Fluoroscopy time was comparable between CONV and TIG, without crossover (2.2 ± 1.2 min versus 2.3 ± 1.2 min; n.s.), however, greater in the case of crossover for CONV (5.8 ± 0.7) and TIG (7.6 ± 3.0; p = 0.0001). Radiation dosage was similar in CONV and the TIG, without crossover (1419 ± 1075, cGy∗cm(2) versus 1690 ± 1138; n.s.), however, greater for CONV (2374 ± 620) and TIG (3733 ± 2281, p = 0.05) with crossover. Overall, the amount of contrast was greater in TIG (56 ± 13 mL) versus CONV (48 ± 3 mL; p = 0.0003). CONV femoral catheters may be the primary choice for radial approach.

  1. Hepatic artery aneurysms (HAAs)

    International Nuclear Information System (INIS)

    Nosratini, H.

    2004-01-01

    The hepatic artery aneurysms are rare, especially in interahepatic branches, The frequency consists of 75-80% extrahepatic and 20-25% intrahepatic. Catheterization is achieved usually from common femoral artery, other methods implemented in the case of unsuccessful catheterization from femoral artery, are translumbar and brachial catheterization. The study consist of 565 patients that were referred to the angiography ward, During seven years of assessment, five cases of hepatic artery aneurysm were found; this is a rare condition reported in the English literature. In the literature as well as in this case report the hepatic artery aneurysms are rare. In reported series the extrahepatic artery aneurysms are found more often than in the intrahepatic artery aneurysm but in this case report intrahepatic artery aneurysms are more than extrahepatic one. (author)

  2. Hepatic artery aneurysm repair: a case report

    Directory of Open Access Journals (Sweden)

    Jaunoo SS

    2009-01-01

    Full Text Available Abstract Introduction Hepatic artery aneurysms remain a clinically significant entity. Their incidence continues to rise slowly and mortality from spontaneous rupture is high. Repair is recommended in those aneurysms greater than 2 cm in diameter. It is not surprising that vascular comorbidities, such as ischaemic heart disease, are common in surgical patients, particularly those with arterial aneurysms such as these. The decision of when to operate on patients who require urgent surgery despite having recently suffered an acute coronary syndrome remains somewhat of a grey and controversial area. We discuss the role of delayed surgery and postoperative followup of this vascular problem. Case presentation A 58-year-old man was admitted with a 5.5 cm hepatic artery aneurysm. The aneurysm was asymptomatic and was an incidental finding as a result of an abdominal computed tomography scan to investigate an episode of haemoptysis (Figure 1. Three weeks prior to admission, the patient had suffered a large inferior myocardial infarction and was treated by thrombolysis and primary coronary angioplasty. Angiographic assessment revealed a large aneurysm of the common hepatic artery involving the origins of the hepatic, gastroduodenal, left and right gastric arteries and the splenic artery (Figures 2 and 3. Endovascular treatment was not considered feasible and immediate surgery was too high-risk in the early post-infarction period. Therefore, surgery was delayed for 3 months when aneurysm repair with reconstruction of the hepatic artery was successfully performed. Graft patency was confirmed with the aid of an abdominal arterial duplex. Plasma levels of conventional liver function enzymes and of alpha-glutathione-S-transferase were within normal limits. This was used to assess the extent of any hepatocellular damage perioperatively. The patient made a good recovery and was well at his routine outpatient check-ups. Conclusion There is no significant

  3. Comparative efficacy and safety of the left versus right radial approach for percutaneous coronary procedures: a meta-analysis including 6870 patients

    Directory of Open Access Journals (Sweden)

    S.L. Xia

    2015-08-01

    Full Text Available The radial approach is widely used in the treatment of patients with coronary artery disease. We conducted a meta-analysis of published results on the efficacy and safety of the left and right radial approaches in patients undergoing percutaneous coronary procedures. A systematic search of reference databases was conducted, and data from 14 randomized controlled trials involving 6870 participants were analyzed. The left radial approach was associated with significant reductions in fluoroscopy time [standardized mean difference (SMD=-0.14, 95% confidence interval (CI=-0.19 to -0.09; P<0.00001] and contrast volume (SMD=-0.07, 95%CI=-0.12 to -0.02; P=0.009. There were no significant differences in rate of procedural failure of the left and the right radial approaches [risk ratios (RR=0.98; 95%CI=0.77-1.25; P=0.88] or procedural time (SMD=-0.05, 95%CI=0.17-0.06; P=0.38. Tortuosity of the subclavian artery (RR=0.27, 95%CI=0.14-0.50; P<0.0001 was reported more frequently with the right radial approach. A greater number of catheters were used with the left than with the right radial approach (SMD=0.25, 95%CI=0.04-0.46; P=0.02. We conclude that the left radial approach is as safe as the right radial approach, and that the left radial approach should be recommended for use in percutaneous coronary procedures, especially in percutaneous coronary angiograms.

  4. Radial optic neurotomy for ischaemic central vein occlusion

    Science.gov (United States)

    Martínez-Jardón, C S; Meza-de Regil, A; Dalma-Weiszhausz, J; Leizaola-Fernández, C; Morales-Cantón, V; Guerrero-Naranjo, J L; Quiroz-Mercado, H

    2005-01-01

    Background/aims: Ischaemic central retinal vein occlusion (CRVO) accounts for 20–50% of all CRVO. No treatment has been proved to be effective. The efficacy of radial optic neurotomy (RON) was evaluated in eyes with ischaemic CRVO. Methods: 10 patients with ischaemic CRVO underwent RON. After pars plana vitrectomy, a microvitreoretinal blade was used to incise the scleral ring, cribriform plate, and adjacent sclera at the nasal edge of the optic disc. Best corrected visual acuity (BCVA), intraocular pressure (IOP), fluorescein angiography (FA), multifocal electroretinography (mfERG), and optical coherence tomography (OCT) were measured preoperatively and at 1, 3, and 6 months postoperatively. Results: No visual improvement was noted in the eyes that underwent RON. FA and mfERG showed no increase in retinal perfusion or retinal function postoperatively. Mean macular central thickness changed from 841 (SD 170) μm preoperatively to 162 (SD 34) μm at the sixth postoperative month. One patient had retinal central artery perforation intraoperatively. One patient developed neovascular glaucoma. Conclusion: RON in ischaemic CRVO did not improve visual function (by mfERG) or visual acuity although macular thickness did improve. This technique may be associated with potential risks. Randomised studies are needed to corroborate these results. PMID:15834084

  5. Bilateral renal artery variation

    OpenAIRE

    Üçerler, Hülya; Üzüm, Yusuf; İkiz, Z. Aslı Aktan

    2014-01-01

    Each kidney is supplied by a single renal artery, although renal artery variations are common. Variations of the renal arteryhave become important with the increasing number of renal transplantations. Numerous studies describe variations in renalartery anatomy. Especially the left renal artery is among the most critical arterial variations, because it is the referred side forresecting the donor kidney. During routine dissection in a formalin fixed male cadaver, we have found a bilateral renal...

  6. The precision segmented reflectors: Moderate mission figure control subsystem

    Science.gov (United States)

    Sevaston, G.; Redding, D.; Lau, K.; Breckenridge, W.; Levine, B.; Nerheim, N.; Sirlin, S.; Kadogawa, H.

    1991-01-01

    A system concept for a space based segmented reflector telescope figure control subsystem is described. The concept employs a two phase architecture in which figure initialization and figure maintenance are independent functions. Figure initialization is accomplished by image sharpening using natural reference targets. Figure maintenance is performed by monitoring the relative positions and alignments of the telescope components using an optical truss. Actuation is achieved using precision positioners. Computer simulation results of figure initialization by pairwise segment coalignment/cophasing and simulated annealing are presented along with figure maintenance results using a wavefront error regulation algorithm. Both functions are shown to perform at acceptable levels for the class of submillimeter telescopes that are serving as the focus of this technology development effort. Component breadboard work as well as plans for a system testbed are discussed.

  7. A figure control sensor for the Large Deployable Reflector (LDR)

    Science.gov (United States)

    Bartman, R.; Dubovitsky, S.

    1988-01-01

    A sensing and control system is required to maintain high optical figure quality in a segmented reflector. Upon detecting a deviation of the segmented surface from its ideal form, the system drives segment mounted actuators to realign the individual segments and thereby return the surface to its intended figure. When the reflector is in use, a set of figure sensors will determine positions of a number of points on the back surface of each of the reflector's segments, each sensor being assigned to a single point. By measuring the positional deviations of these points from previously established nominal values, the figure sensors provide the control system with the information required to maintain the reflector's optical figure. The optical lever, multiple wavelength interferometer, and electronic capacitive sensor, the most promising technologies for the development of the figure sensor, are illustrated. It is concluded that to select a particular implementation of the figure sensors, performance requirement will be refined and relevant technologies investigated further.

  8. FIGURATIVE AND LEXICAL VARIETIES IN FACEBOOK POSTS

    Directory of Open Access Journals (Sweden)

    I Gusti Ayu Vina Widiadnya Putri

    2017-11-01

    Full Text Available Language is a highly elaborated signaling system. It serves various functions in communication, it is used to share ideas, convey feelings and emotions, etc. The researchers are interested to uncover more on how people use language in terms of its variety and lexical in one of the popular social media networking platforms that we all know as Facebook. Based on the aforementioned background of the study, the problem of the research can be formulated as follows: (1 what are the figurative languages used in Facebook posts by female and male Facebook users? (2 How are the emotional lexical varieties e.g. used in Facebook posts? Method of research is a procedure needed to do the research better. In this case, method of research covers data source, data collection and data analysis. The data of this research have been taken from Facebook, it is as an online social networking website where people can create profiles, share information such as photos and quotes about themselves, and respond or link to the information posted by others. The method that used in collecting data is method of library research. They are collected by reading the Facebook user’s post, by underlining and note taking as well. The data analysis is the last step in this process of writing this research. The analysis is done by descriptive method. To make the analysis clearer, all of examples are completed with explanation. Referring to the first research problem, there are some figurative languages used by the Facebook users such as, Simile (female 1 or 4.3% and male 0%, Metaphor (female 4 or 17.3% and male 0%,, Personification (female 3 or 1.3% and male 1% or 4.3%,, Hyperbole (female 4 or 17.3% and male 1 or 4.3%, and Idiom (female 3 or 13% and male 0%,. Furthermore, in regards to the second problem that is emotional lexical used by the Facebook Users, we could mention that both the Augmentatives (female 3 or 13% and male 1 or 4.3%, and Euphemisms (female 1 or 4.3% and male 1 or

  9. Hepatocellular carcinoma with extensive hepatic artery injury: transcatheter arterial chemoembolization through collaterals after coil embolizatoin of gastric arteries

    International Nuclear Information System (INIS)

    Kim, Gab Choul; Yoon, Hyun Ki; Hwang, Jae Cheol; Lee, Duck Hee; Song, Ho Young; Suh, Dong Jin; Lee, Yung Sang; Chung, Young Hwa; Sung, Gyu Bo; Ko, Ki Young

    1999-01-01

    To evaluate the efficacy and safety of transcatheter arterial chemoembolization(TACE) after coil embolization of the gastroduodenal artery in hepatocellular carcinoma cases with multiple collateral arteries caused by proper hepatic artery injury. Between March 1997 and November 1998, a prospective trial of transcatheter arterial chemoembolization (TACE) was performed through collaterals from the gastroduodenal artery of 31 hepatocellular carcinoma patients with extensive proper hepatic artery injury due to repeated TACE. Among this number, 16 (group A) underwent TACE after coil embolization of the right gastric and gastroduodenal artery. The other 15 patients (group B) underwent TACE without coil embolization. The two groups had the same TNM stage and Clild-Pugh status. During the follow-up period, group A underwent additional TACE 3.3 times, and group B 2.8 times. The therapeutic effect of TACE was evaluated with computed tomography and by measuring alpha-fetoprotein levels. Complications were evaluated by means of gastrofibroscopy, laboratory data, and evaluation of the patients' clinical symptoms. The results obtained after six months and one year were compared within and between each group. At six months follow-up, CT findings had improved or were unchanged in 11 patients(69 %) in group A, and four patients(27 %) in group B(p = 0.032). In ten patients in each group, the level of alpha-fetoprotein was above 200 ng/ml. Its level was decreased in five patients(50 %) and three patients(30 %), respectively. The six-month survival rate was 81 % (13/16) in group A and 67% (10/15) in group B (p 0.43), while the one-year survival figures for these two groups were 50 % (8/16) and 20 % (3/15), respectively(p = 0.135). In group A, the CT findings were steady in five out of eight patients(63 %), while in groupB, CT findings showed that tumors with increased alpha-fetoprotein levels had increased in size and/or number. In group A, it was found that in two (33 %) of six

  10. Hepatocellular carcinoma with extensive hepatic artery injury: transcatheter arterial chemoembolization through collaterals after coil embolizatoin of gastric arteries

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gab Choul; Yoon, Hyun Ki; Hwang, Jae Cheol; Lee, Duck Hee; Song, Ho Young; Suh, Dong Jin; Lee, Yung Sang; Chung, Young Hwa; Sung, Gyu Bo [Ulsan Univ. College of Medicine, Seoul (Korea, Republic of); Ko, Ki Young [Catholic Univ. College of Medicine, Seoul (Korea, Republic of)

    1999-09-01

    To evaluate the efficacy and safety of transcatheter arterial chemoembolization(TACE) after coil embolization of the gastroduodenal artery in hepatocellular carcinoma cases with multiple collateral arteries caused by proper hepatic artery injury. Between March 1997 and November 1998, a prospective trial of transcatheter arterial chemoembolization (TACE) was performed through collaterals from the gastroduodenal artery of 31 hepatocellular carcinoma patients with extensive proper hepatic artery injury due to repeated TACE. Among this number, 16 (group A) underwent TACE after coil embolization of the right gastric and gastroduodenal artery. The other 15 patients (group B) underwent TACE without coil embolization. The two groups had the same TNM stage and Clild-Pugh status. During the follow-up period, group A underwent additional TACE 3.3 times, and group B 2.8 times. The therapeutic effect of TACE was evaluated with computed tomography and by measuring alpha-fetoprotein levels. Complications were evaluated by means of gastrofibroscopy, laboratory data, and evaluation of the patients' clinical symptoms. The results obtained after six months and one year were compared within and between each group. At six months follow-up, CT findings had improved or were unchanged in 11 patients(69 %) in group A, and four patients(27 %) in group B(p = 0.032). In ten patients in each group, the level of alpha-fetoprotein was above 200 ng/ml. Its level was decreased in five patients(50 %) and three patients(30 %), respectively. The six-month survival rate was 81 % (13/16) in group A and 67% (10/15) in group B (p 0.43), while the one-year survival figures for these two groups were 50 % (8/16) and 20 % (3/15), respectively(p = 0.135). In group A, the CT findings were steady in five out of eight patients(63 %), while in groupB, CT findings showed that tumors with increased alpha-fetoprotein levels had increased in size and/or number. In group A, it was found that in two (33 %) of six

  11. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gunja, Ateka; Pandey, Yagya [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Xie, Hui [Division of Epidemiology and Biostatistics, University of Illinois at Chicago, Chicago, IL (United States); Faculty of Health Sciences, Simon Fraser University, Burnaby, BC (Canada); Wolska, Beata M. [Department of Physiology and Biophysics, Center for Cardiovascular Research, University of Illinois at Chicago, Chicago, IL (United States); Shroff, Adhir R.; Ardati, Amer K. [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States); Vidovich, Mladen I., E-mail: miv@uic.edu [Department of Veterans Affairs, Jesse Brown VA Medical Center, Chicago, IL (United States); Division of Cardiology, Department of Medicine, University of Illinois at Chicago, Chicago, IL (United States)

    2017-04-15

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm{sup 2}). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm{sup 2} ± 74.0 vs. 41.9 mGy cm{sup 2} ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image

  12. Image noise reduction technology reduces radiation in a radial-first cardiac catheterization laboratory

    International Nuclear Information System (INIS)

    Gunja, Ateka; Pandey, Yagya; Xie, Hui; Wolska, Beata M.; Shroff, Adhir R.; Ardati, Amer K.; Vidovich, Mladen I.

    2017-01-01

    Background: Transradial coronary angiography (TRA) has been associated with increased radiation doses. We hypothesized that contemporary image noise reduction technology would reduce radiation doses in the cardiac catheterization laboratory in a typical clinical setting. Methods and results: We performed a single-center, retrospective analysis of 400 consecutive patients who underwent diagnostic and interventional cardiac catheterizations in a predominantly TRA laboratory with traditional fluoroscopy (N = 200) and a new image noise reduction fluoroscopy system (N = 200). The primary endpoint was radiation dose (mGy cm"2). Secondary endpoints were contrast dose, fluoroscopy times, number of cineangiograms, and radiation dose by operator between the two study periods. Radiation was reduced by 44.7% between the old and new cardiac catheterization laboratory (75.8 mGy cm"2 ± 74.0 vs. 41.9 mGy cm"2 ± 40.7, p < 0.0001). Radiation was reduced for both diagnostic procedures (45.9%, p < 0.0001) and interventional procedures (37.7%, p < 0.0001). There was no statistically significant difference in radiation dose between individual operators (p = 0.84). In multivariate analysis, radiation dose remained significantly decreased with the use of the new system (p < 0.0001) and was associated with weight (p < 0.0001), previous coronary artery bypass grafting (p < 0.0007) and greater than 3 stents used (p < 0.0004). TRA was used in 90% of all cases in both periods. Compared with a transfemoral approach (TFA), TRA was not associated with higher radiation doses (p = 0.20). Conclusions: Image noise reduction technology significantly reduces radiation dose in a contemporary radial-first cardiac catheterization clinical practice. - Highlights: • Radial arterial access has been associated with higher doses compared to femoral access. • In a radial-first cardiac catheterization laboratory (90% radial) we examined radiation doses reduction with a contemporary image-noise compared to

  13. Ulnar artery: The Ulysses ultimate resort for coronary procedures

    Directory of Open Access Journals (Sweden)

    George Hahalis, MD, PhD

    2016-07-01

    Full Text Available Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA. Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates.

  14. Ulnar artery: The Ulysses ultimate resort for coronary procedures.

    Science.gov (United States)

    Hahalis, George; Deftereos, Spyridon; Bertrand, Olivier F

    2016-08-20

    Despite the increasing worldwide adoption of the transradial access site, the ulnar artery (UA) only very infrequently serves as a primary option for coronary procedures. In contrast to the uncertainty surrounding previous reports regarding the feasibility and safety, recent data from larger registries and randomized trials provide more conclusive evidence that the transulnar route may be safely selected as an alternative arterial access approach. However, a default transulnar strategy appears time-consuming and is associated with higher crossover rates compared with the radial artery (RA). Once arterial access is obtained, the likelihood of a successful coronary procedure is high and similar between the two forearm arteries. The UA has similar flow-mediating vasodilating properties with and seems at least as vulnerable as the RA with regard to incident occlusion, with UA occlusion (UAO) rates being probably higher than previously anticipated. A learning curve effect may not be apparent for crossover rates among experienced radialists, but increasing experience is associated with reduction in the fluoroscopy time, contrast volume and frequency of large hematoma formation. The UA may represents an important alternative access site for coronary procedures, and experienced radial operators should obtain additional skills to perform the transulnar approach. Nevertheless, in view of this method's lower feasibility compared to the RA, an initial ulnar access strategy should be reserved for carefully selected patients to ensure satisfactory cannulation rates. Copyright © 2016 Hellenic Cardiological Society. Published by Elsevier B.V. All rights reserved.

  15. Evaluation of layback spin in figure skating

    Directory of Open Access Journals (Sweden)

    Jastšenjski Ksenija

    2011-01-01

    Full Text Available Layback spin is considered as one of the most beautiful and elegant spins performed in figure skating. It is also one of the required spins in competitive short program in female category. Different techniques of executing layback spin with variations in changing the positions of free parts of the body, as well as the evaluation of layback spin in accordance with ISU rules and regulations, which have been used in all International Skating Federation competitions since 2004 (World and European championships, Olympic Games are presented in this paper. Due to very difficult position of the body while performing a layback spin, it is essential that the skaters who want to master it should have excellent agility (especially of the spinal column and shoulder and knee joints and balance. Layback spin performance requires significant skating knowledge, so it cannot be performed by beginners. Depending on the fl exibility and creativity, a skater can execute various positions of the head, arms, body and free leg while performing a layback spin. In some cases, these variations can increase the level of difficulty, and in others only the mark given for executing this spin.

  16. An economics figure of merit in ALPS

    International Nuclear Information System (INIS)

    Shatilla, Y.A.

    2000-01-01

    One of the most pressing issues facing the deregulated nuclear electric power industry is its economic competitiveness when compared to other sources of electrical power. Traditionally, finding the optimum loading pattern (LP) that meets all the safety and operational objective functions and at the same time produces the most attractive economical solutions is an iterative process. This is because (a) LP search tools usually lack the capability to generate equilibrium solutions and (b) economics objective functions are hard to include in the search process. In this paper, the Westinghouse Advanced Loading Pattern Search code (ALPS) has been demonstrated to successfully find LPs that meet user-defined operational and safety as well as economics objectives. This has been made possible by the development of TULIP language that allows the integration of external procedures into the search process of the main program, ALPS. In the example given, an economic figure of merit (EFM) has been defined and included via TULIP script into the fuel management optimization problem of a three-loop Westinghouse core operating an 18-month cycle. The LPs found by ALPS exhibit a clear trend of meeting and, in some cases, exceeding the EFM objective function defined for the ALPS search process a priori

  17. Running the figure to the ground: figure-ground segmentation during visual search.

    Science.gov (United States)

    Ralph, Brandon C W; Seli, Paul; Cheng, Vivian O Y; Solman, Grayden J F; Smilek, Daniel

    2014-04-01

    We examined how figure-ground segmentation occurs across multiple regions of a visual array during a visual search task. Stimuli consisted of arrays of black-and-white figure-ground images in which roughly half of each image depicted a meaningful object, whereas the other half constituted a less meaningful shape. The colours of the meaningful regions of the targets and distractors were either the same (congruent) or different (incongruent). We found that incongruent targets took longer to locate than congruent targets (Experiments 1, 2, and 3) and that this segmentation-congruency effect decreased when the number of search items was reduced (Experiment 2). Furthermore, an analysis of eye movements revealed that participants spent more time scrutinising the target before confirming its identity on incongruent trials than on congruent trials (Experiment 3). These findings suggest that the distractor context influences target segmentation and detection during visual search. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan

    Directory of Open Access Journals (Sweden)

    Nurhusna N

    2017-08-01

    Full Text Available Page Header User Username Password Remember me Editorial Team Editor Policies Mechanism & Ethics Author Guideline Reference Tools: About The Authors Nurhusna N Indonesia F Sri Susilaningsih Purwo Suwigjo Article Tools Print this article Indexing metadata How to cite item Finding References Review policy Email this article (Login required Email the author (Login required Information For Readers For Authors For Librarians Journal Content Search Search Scope Browse By Issue By Author By Title Home About Login Register Search Current Archives Announcements Register Index Contact Us Home > Vol 2, No 1 (2014 > N Metode Barbeau Test dalam Menilai Keutuhan Arteri Radialis Pascaintervensi Koroner Perkutan Nurhusna N, F Sri Susilaningsih, Purwo Suwigjo Abstract Radial artery occlusion merupakan salah satu komplikasi vaskular postkateterisasi jantung trans radial. Kompresi lokal menggunakan alat kompresi setelah tindakan kateterisasi jantung trans radial dapat menurunkan angka kejadian komplikasi vaskular Radial Artery Occlusion(RAO. Penelitian ini bertujuan untuk mengetahui perbandingan antara metode Barbeau test dan metode pengamatan klinik dalam menilai keutuhan arteri radialis selama proses kompresi pada pasien postprosedur kateterisasi jantung trans radial. Penelitian ini merupakan penelitian kuantitatif dengan desain studi komparatif. Subjek penelitian adalah 20 pasien yang menjalani prosedur kateterisasi jantung dengan akses arteri radialis. Pengukuran dilakukan secara bertahap menit ke-15 dan setelah tiga jam menggunakan alat kompresi stepty-p. Uji komparasi menggunakan uji McNemar. Data univariat dianalisis menggunakan distribusi frekuensi. Hasil uji statistik menunjukkan ada perbedaan penilaian keutuhan arteri radialis antara metode Barbeau testdengan metode pengamatan klinik pada menit ke-15 (p=0.035 dan ke-30 (p=0.035. Namun secara keseluruhan hasil uji statistik menunjukkan tidak ada perbedaan yang bermakna dalam menilai kepatenan arteri pada

  19. WWER radial reflector modeling by diffusion codes

    International Nuclear Information System (INIS)

    Petkov, P. T.; Mittag, S.

    2005-01-01

    The two commonly used approaches to describe the WWER radial reflectors in diffusion codes, by albedo on the core-reflector boundary and by a ring of diffusive assembly size nodes, are discussed. The advantages and disadvantages of the first approach are presented first, then the Koebke's equivalence theory is outlined and its implementation for the WWER radial reflectors is discussed. Results for the WWER-1000 reactor are presented. Then the boundary conditions on the outer reflector boundary are discussed. The possibility to divide the library into fuel assembly and reflector parts and to generate each library by a separate code package is discussed. Finally, the homogenization errors for rodded assemblies are presented and discussed (Author)

  20. Oculoauriculovertebral spectrum with radial anomaly in child.

    Science.gov (United States)

    Taksande, Amar; Vilhekar, Krishna

    2013-01-01

    Oculoauriculovertebral spectrum (OAVS) or Goldenhar syndrome is a wide spectrum of congenital anomalies that involves structures arising from the first and second branchial arches. It is characterized by a wide spectrum of symptoms and physical features. These abnormalities mainly involve the cheekbones, jaws, mouth, ears, eyes, or vertebrae. Other conditions with ear and/or radial involvement, such as, the Nager syndrome, Holt-Oram syndrome, Radial-renal syndrome, facioauriculoradial dysplasia, Fanconi anemia, and Vertebral, Anal atresia, Cardiac, Trachea, Esophageal, Renal, and Limb (VACTERL) association should be considered for differential diagnosis. Here we report a child who had facial asymmetry, microsomia, microtia, congenital facial nerve palsy, conductive hearing loss, skin tags, iris coloboma, and preaxial polydactyly.

  1. Oculoauriculovertebral spectrum with radial anomaly in child

    Directory of Open Access Journals (Sweden)

    Amar Taksande

    2013-01-01

    Full Text Available Oculoauriculovertebral spectrum (OAVS or Goldenhar syndrome is a wide spectrum of congenital anomalies that involves structures arising from the first and second branchial arches. It is characterized by a wide spectrum of symptoms and physical features. These abnormalities mainly involve the cheekbones, jaws, mouth, ears, eyes, or vertebrae. Other conditions with ear and/or radial involvement, such as, the Nager syndrome, Holt-Oram syndrome, Radial-renal syndrome, facioauriculoradial dysplasia, Fanconi anemia, and Vertebral, Anal atresia, Cardiac, Trachea, Esophageal, Renal, and Limb (VACTERL association should be considered for differential diagnosis. Here we report a child who had facial asymmetry, microsomia, microtia, congenital facial nerve palsy, conductive hearing loss, skin tags, iris coloboma, and preaxial polydactyly.

  2. Linear radial pulsation theory. Lecture 5

    International Nuclear Information System (INIS)

    Cox, A.N.

    1983-01-01

    We describe a method for getting an equilibrium stellar envelope model using as input the total mass, the envelope mass, the surface effective temperature, the total surface luminosity, and the composition of the envelope. Then wih the structure of the envelope model known, we present a method for obtaining the raidal pulsation periods and growth rates for low order modes. The large amplitude pulsations observed for the yellow and red giants and supergiants are always these radial models, but for the stars nearer the main sequence, as for all of our stars and for the white dwarfs, there frequently are nonradial modes occuring also. Application of linear theory radial pulsation theory is made to the giant star sigma Scuti variables, while the linear nonradial theory will be used for the B stars in later lectures

  3. SpicyNodes Radial Map Engine

    Science.gov (United States)

    Douma, M.; Ligierko, G.; Angelov, I.

    2008-10-01

    The need for information has increased exponentially over the past decades. The current systems for constructing, exploring, classifying, organizing, and searching information face the growing challenge of enabling their users to operate efficiently and intuitively in knowledge-heavy environments. This paper presents SpicyNodes, an advanced user interface for difficult interaction contexts. It is based on an underlying structure known as a radial map, which allows users to manipulate and interact in a natural manner with entities called nodes. This technology overcomes certain limitations of existing solutions and solves the problem of browsing complex sets of linked information. SpicyNodes is also an organic system that projects users into a living space, stimulating exploratory behavior and fostering creative thought. Our interactive radial layout is used for educational purposes and has the potential for numerous other applications.

  4. Stability of a radial immiscible drive

    Energy Technology Data Exchange (ETDEWEB)

    Bataille, J

    1968-11-01

    The stability of the displacement front between 2 immiscible fluids of radial flow between 2 parallel plates (Hele-Shaw model) is studied mathematically by superposing onto the circular displacement front a sinusoidal perturbation. The equations are reduced to dimensionless variables, and it is shown that the stable and unstable domains in a plot: dimensionless viscosity vs. dimensionless time are separated by a polygonal contour, each side of the contour being characterized by the (integer) number of perturbations along the circumference. There is a critical reduced time below which the perturbations are amortized but beyond which they are amplified. Experimental results have been in fair general agreement with theoretical results, the divergence between them being attributable to neglecting capillary phenomena, which may become very important at large radial distances. One test with miscible fluids has shown that even in this case, there is a critical time or an equivalent critical radius.

  5. Variational method for integrating radial gradient field

    Science.gov (United States)

    Legarda-Saenz, Ricardo; Brito-Loeza, Carlos; Rivera, Mariano; Espinosa-Romero, Arturo

    2014-12-01

    We propose a variational method for integrating information obtained from circular fringe pattern. The proposed method is a suitable choice for objects with radial symmetry. First, we analyze the information contained in the fringe pattern captured by the experimental setup and then move to formulate the problem of recovering the wavefront using techniques from calculus of variations. The performance of the method is demonstrated by numerical experiments with both synthetic and real data.

  6. Moment approach to tandem mirror radial transport

    International Nuclear Information System (INIS)

    Siebert, K.D.; Callen, J.D.

    1986-02-01

    A moment approach is proposed for the study of tandem mirror radial transport in the resonant plateau regime. The salient features of the method are described with reference to axisymmetric tokamak transport theory. In particular, the importance of momentum conservation to the establishment of the azimuthal variations in the electrostatic potential is demonstrated. Also, an ad hoc drift kinetic equation is solved to determine parallel viscosity coefficients which are required to close the moment system

  7. Numerical simulation of radial compressor stage

    Science.gov (United States)

    Syka, T.; Luňáček, O.

    2013-04-01

    Article describes numerical simulations of air flow in radial compressor stage in NUMECA CFD software. In simulations geometry variants with and without seals are used. During tasks evaluating was observed seals influence on flow field and performance parameters of compressor stage. Also is described CFDresults comparison with results from design software based on experimental measurements and monitoring of influence of seals construction on compressor stage efficiency.

  8. Numerical simulation of radial compressor stage

    OpenAIRE

    Luňáček O.; Syka T.

    2013-01-01

    Article describes numerical simulations of air flow in radial compressor stage in NUMECA CFD software. In simulations geometry variants with and without seals are used. During tasks evaluating was observed seals influence on flow field and performance parameters of compressor stage. Also is described CFDresults comparison with results from design software based on experimental measurements and monitoring of influence of seals construction on compressor stage efficiency.

  9. Numerical simulation of radial compressor stage

    Directory of Open Access Journals (Sweden)

    Luňáček O.

    2013-04-01

    Full Text Available Article describes numerical simulations of air flow in radial compressor stage in NUMECA CFD software. In simulations geometry variants with and without seals are used. During tasks evaluating was observed seals influence on flow field and performance parameters of compressor stage. Also is described CFDresults comparison with results from design software based on experimental measurements and monitoring of influence of seals construction on compressor stage efficiency.

  10. Radial excitations in nucleon-nucleon scattering

    International Nuclear Information System (INIS)

    Silvestre-Brac, B.; Carbonell, J.; Gignoux, C.

    1986-01-01

    In the non-relativistic constituent quark model, the role of the radial excitations of the nucleon is studied within a resonating group approach of the nucleon-nucleon scattering. It is shown that, rather than the inclusion of new channels, it is important to include mixed-symmetry spin-isospin components in the nucleon wave function. It is also found that during the collision there is no significant deformation of the nucleon. (orig.)

  11. Learning Methods for Radial Basis Functions Networks

    Czech Academy of Sciences Publication Activity Database

    Neruda, Roman; Kudová, Petra

    2005-01-01

    Roč. 21, - (2005), s. 1131-1142 ISSN 0167-739X R&D Projects: GA ČR GP201/03/P163; GA ČR GA201/02/0428 Institutional research plan: CEZ:AV0Z10300504 Keywords : radial basis function networks * hybrid supervised learning * genetic algorithms * benchmarking Subject RIV: BA - General Mathematics Impact factor: 0.555, year: 2005

  12. Fast radial basis functions for engineering applications

    CERN Document Server

    Biancolini, Marco Evangelos

    2017-01-01

    This book presents the first “How To” guide to the use of radial basis functions (RBF). It provides a clear vision of their potential, an overview of ready-for-use computational tools and precise guidelines to implement new engineering applications of RBF. Radial basis functions (RBF) are a mathematical tool mature enough for useful engineering applications. Their mathematical foundation is well established and the tool has proven to be effective in many fields, as the mathematical framework can be adapted in several ways. A candidate application can be faced considering the features of RBF:  multidimensional space (including 2D and 3D), numerous radial functions available, global and compact support, interpolation/regression. This great flexibility makes RBF attractive – and their great potential has only been partially discovered. This is because of the difficulty in taking a first step toward RBF as they are not commonly part of engineers’ cultural background, but also due to the numerical complex...

  13. Fuel radial design using Path Relinking

    International Nuclear Information System (INIS)

    Campos S, Y.

    2007-01-01

    The present work shows the obtained results when implementing the combinatory optimization technique well-known as Path Re linking (Re-linkage of Trajectories), to the problem of the radial design of nuclear fuel assemblies, for boiling water reactors (BWR Boiling Water Reactor by its initials in English), this type of reactors is those that are used in the Laguna Verde Nucleo electric Central, Veracruz. As in any other electric power generation plant of that make use of some fuel to produce heat and that it needs each certain time (from 12 to 14 months) to make a supply of the same one, because this it wears away or it burns, in the nucleolectric plants to this activity is denominated fuel reload. In this reload different activities intervene, among those which its highlight the radial and axial designs of fuel assemblies, the patterns of control rods and the multi cycles study, each one of these stages with their own complexity. This work was limited to study in independent form the radial design, without considering the other activities. These phases are basic for the fuel reload design and of reactor operation strategies. (Author)

  14. Development of a Radial Deconsolidation Method

    Energy Technology Data Exchange (ETDEWEB)

    Helmreich, Grant W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Montgomery, Fred C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hunn, John D. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2015-12-01

    A series of experiments have been initiated to determine the retention or mobility of fission products* in AGR fuel compacts [Petti, et al. 2010]. This information is needed to refine fission product transport models. The AGR-3/4 irradiation test involved half-inch-long compacts that each contained twenty designed-to-fail (DTF) particles, with 20-μm thick carbon-coated kernels whose coatings were deliberately fabricated such that they would crack under irradiation, providing a known source of post-irradiation isotopes. The DTF particles in these compacts were axially distributed along the compact centerline so that the diffusion of fission products released from the DTF kernels would be radially symmetric [Hunn, et al. 2012; Hunn et al. 2011; Kercher, et al. 2011; Hunn, et al. 2007]. Compacts containing DTF particles were irradiated at Idaho National Laboratory (INL) at the Advanced Test Reactor (ATR) [Collin, 2015]. Analysis of the diffusion of these various post-irradiation isotopes through the compact requires a method to radially deconsolidate the compacts so that nested-annular volumes may be analyzed for post-irradiation isotope inventory in the compact matrix, TRISO outer pyrolytic carbon (OPyC), and DTF kernels. An effective radial deconsolidation method and apparatus appropriate to this application has been developed and parametrically characterized.

  15. Jet pump assisted artery

    Science.gov (United States)

    1975-01-01

    A procedure for priming an arterial heat pump is reported; the procedure also has a means for maintaining the pump in a primed state. This concept utilizes a capillary driven jet pump to create the necessary suction to fill the artery. Basically, the jet pump consists of a venturi or nozzle-diffuser type constriction in the vapor passage. The throat of this venturi is connected to the artery. Thus vapor, gas, liquid, or a combination of the above is pumped continuously out of the artery. As a result, the artery is always filled with liquid and an adequate supply of working fluid is provided to the evaporator of the heat pipe.

  16. N-acetylcysteine enhances nitroglycerin-induced headache and cranial arterial responses

    DEFF Research Database (Denmark)

    Iversen, Helle Klingenberg

    1992-01-01

    The effects of N-acetylcysteine, a sulfhydryl group donor, on nitroglycerin-induced headache and dilation of temporal and radial arteries were investigated in 11 healthy volunteers. Nitroglycerin, 0.06 microgram/kg/min, was infused for 20 minutes immediately after and 120 minutes after pretreatment...... response (median headache score, 3 versus 1), and the headache retained its vascular characteristics. Temporal artery dilation was also potentiated by N-acetylcysteine, 139% +/- 3% versus 127% +/- 3% of baseline, whereas the radial artery was unaffected. The potentiation was most pronounced after the first...... nitroglycerin infusion (12% versus 4.5% compared with placebo). A prolonged dilation of the temporal artery was observed only after the first nitroglycerin infusion, when high levels of N-acetylcysteine were present....

  17. Non Newtonian Behavior of Blood in Presence of Arterial Occlusion

    OpenAIRE

    Dr.Arun Kumar Maiti

    2016-01-01

    The objective of the present numerical model is to investigate the effect of shape of stenosis on blood flow through an artery using Bingham plastic fluid model. Blood is modeled as Bingham plastic fluid in a uniform circular tube with an axially symmetric but radially non symmetric stenosis. The expressions for flux, dimensionless resistance to flow with stenosis shape parameter, stenosis length and stenosis size have been shown graphically

  18. Linear theory radial and nonradial pulsations of DA dwarf stars

    International Nuclear Information System (INIS)

    Starrfield, S.; Cox, A.N.; Hodson, S.; Pesnell, W.D.

    1982-01-01

    The Los Alamos stellar envelope and radial linear non-adiabatic computer code, along with a new Los Alamos non-radial code are used to investigate the total hydrogen mass necessary to produce the non-radial instability of DA dwarfs

  19. Radial distribution of ions in pores with a surface charge

    NARCIS (Netherlands)

    Stegen, J.H.G. van der; Görtzen, J.; Kuipers, J.A.M.; Hogendoorn, J.A.; Versteeg, G.F.

    2001-01-01

    A sorption model applicable to calculate the radial equilibrium concentrations of ions in the pores of ion-selective membranes with a pore structure is developed. The model is called the radial uptake model. Because the model is applied to a Nafion sulfonic layer with very small pores and the radial

  20. Missing left main ostio-proximal coronary artery disease during angiography using tiger catheter

    Directory of Open Access Journals (Sweden)

    Biswajit Majumder

    2016-01-01

    Full Text Available Coronary angiography by right radial artery route using Optitorque Tiger catheter is on the rise given the low rate of local complications and feasibility to perform it as a day-care procedure. We report here a case of coronary angiography performed using Optitorque Tiger catheter (5-French which resulted in a diagnostic error, missing the ostio-proximal left main coronary artery disease which was later detected using EBU 3.5 guide catheter (7-French while performing angioplasty.

  1. Long-term monitoring of arterial pO2 in burned patients.

    Science.gov (United States)

    Nilsson, E; Arnander, C

    1984-02-01

    Five patients, who were treated in a special ward for burns were followed by continuous intra-arterial pO2 monitoring for a total of 1612 h (range 13-604 h). The pao2 catheter electrodes used were surface-heparinized, and inserted either in the radial or the femoral artery. Some electrodes were accidentally withdrawn. Recalibration was performed for two of the 10 electrodes used. These electrodes presented a changed sensitivity after heavy stretching of the sensor during the nursing. The sensitivity of one of these electrodes was altered downwards and the other one upwards. After recalibration the pao2 electrodes presented accurate values for the rest of the monitoring period. Without compensation for drift, the pao2 electrode readout was compared to the results of traditional blood-gas analysis, which served as a reference. The regression function found was y = -0.62 + 1.04 chi (r = 0.93, SD = 1.40, n = 60). The blood flow velocity around some of the pao2 electrodes was studied by the pulsed Doppler technique. There was no influence of the surface-heparinized pao2 electrode on the femoral artery blood flow velocity as compared to the contralateral, non-catheterized femoral artery. The blood flow velocity proximal to a traditional radial artery catheter was compared to the flow velocity in the contralateral radial artery containing a surface-heparinized pao2 electrode. The surface-heparinized electrode did not decrease the mean flow velocity in contrast with the traditional radial artery catheter, which had to be withdrawn after 8 days because of clotting. The surface-heparinized catheter electrode was still monitoring pao2 accurately after 25 days in the artery, which was the longest period studied for a particular sensor.

  2. Experimental feasibility study of radial injection cooling of three-pad radial air foil bearings

    Science.gov (United States)

    Shrestha, Suman K.

    Air foil bearings use ambient air as a lubricant allowing environment-friendly operation. When they are designed, installed, and operated properly, air foil bearings are very cost effective and reliable solution to oil-free turbomachinery. Because air is used as a lubricant, there are no mechanical contacts between the rotor and bearings and when the rotor is lifted off the bearing, near frictionless quiet operation is possible. However, due to the high speed operation, thermal management is one of the very important design factors to consider. Most widely accepted practice of the cooling method is axial cooling, which uses cooling air passing through heat exchange channels formed underneath the bearing pad. Advantage is no hardware modification to implement the axial cooling because elastic foundation structure of foil bearing serves as a heat exchange channels. Disadvantage is axial temperature gradient on the journal shaft and bearing. This work presents the experimental feasibility study of alternative cooling method using radial injection of cooling air directly on the rotor shaft. The injection speeds, number of nozzles, location of nozzles, total air flow rate are important factors determining the effectiveness of the radial injection cooling method. Effectiveness of the radial injection cooling was compared with traditional axial cooling method. A previously constructed test rig was modified to accommodate a new motor with higher torque and radial injection cooling. The radial injection cooling utilizes the direct air injection to the inlet region of air film from three locations at 120° from one another with each location having three axially separated holes. In axial cooling, a certain axial pressure gradient is applied across the bearing to induce axial cooling air through bump foil channels. For the comparison of the two methods, the same amount of cooling air flow rate was used for both axial cooling and radial injection. Cooling air flow rate was

  3. Key figures for the regional- and distribution grid

    International Nuclear Information System (INIS)

    Vikingstad, S.

    1996-02-01

    In Norway, improving the efficiency of the hydroelectric grid operation is a stated goal of the Energy Act. Several studies have identified potential profits of such improvement. This publication focuses on costs and improvement potentials. Publication of key figures may stimulate grid owners, boards and administrations to improve the operating efficiency of their grids. The publication shows key figures for the regional- and distribution grid and is based on accounting data for 1994. The key figures are divided into: (1) Cost structure: The key figures express the relative contributions of each cost component to the total income of the grid, (2) Costs and physical quantities: The key figures show the cost of delivering the transport services, (3) Physical quantities: The key figures describe the working conditions of the energy utility. It appears that the cost structure of the sector varies considerably. The same is true of the cost related to the delivery of grid services. 30 figs., 6 tabs

  4. Lighting, backlighting and watercolor illusions and the laws of figurality.

    Science.gov (United States)

    Pinna, Baingio; Reeves, Adam

    2006-01-01

    We report some novel 'lighting' and 'backlighting' effects in plane figures similar to those which induce the 'watercolor illusion', that is, figures made with outlines composed of juxtaposed parallel lines varying in brightness and chromatic color. These new effects show 'illumination' as an emergent percept, and show how arrangements of 'dark and light' along the boundaries of various plane figures model the volume and strengthen the illusion of depth. To account for these various effects we propose several phenomenological 'laws of figurality' to add to the Gestalt laws of organization and figure-ground segregation. We offer a set of meta-laws which are speculative but which serve to integrate and organize the phenomenological laws. These laws indicate how luminance gradient profiles across boundary contours define both the 3D appearance of figures and the properties of the light reflected from their volumetric shapes.

  5. Experimental exposure to diesel exhaust increases arterial stiffness in man

    Directory of Open Access Journals (Sweden)

    Newby David E

    2009-03-01

    Full Text Available Abstract Introduction Exposure to air pollution is associated with increased cardiovascular morbidity, although the underlying mechanisms are unclear. Vascular dysfunction reduces arterial compliance and increases central arterial pressure and left ventricular after-load. We determined the effect of diesel exhaust exposure on arterial compliance using a validated non-invasive measure of arterial stiffness. Methods In a double-blind randomized fashion, 12 healthy volunteers were exposed to diesel exhaust (approximately 350 μg/m3 or filtered air for one hour during moderate exercise. Arterial stiffness was measured using applanation tonometry at the radial artery for pulse wave analysis (PWA, as well as at the femoral and carotid arteries for pulse wave velocity (PWV. PWA was performed 10, 20 and 30 min, and carotid-femoral PWV 40 min, post-exposure. Augmentation pressure (AP, augmentation index (AIx and time to wave reflection (Tr were calculated. Results Blood pressure, AP and AIx were generally low reflecting compliant arteries. In comparison to filtered air, diesel exhaust exposure induced an increase in AP of 2.5 mmHg (p = 0.02 and in AIx of 7.8% (p = 0.01, along with a 16 ms reduction in Tr (p = 0.03, 10 minutes post-exposure. Conclusion Acute exposure to diesel exhaust is associated with an immediate and transient increase in arterial stiffness. This may, in part, explain the increased risk for cardiovascular disease associated with air pollution exposure. If our findings are confirmed in larger cohorts of susceptible populations, this simple non-invasive method of assessing arterial stiffness may become a useful technique in measuring the impact of real world exposures to combustion derived-air pollution.

  6. Logo design: examining consumer response to figurativeness across cultures

    OpenAIRE

    Machado, Joana César; Vacas de Carvalho, Leonor; Torres, Anna; Van de Velden, Michel; Costa, Patrício

    2014-01-01

    Literature concerned with logo strategy suggests that the aesthetic appeal of brand logo significantly influences consumer reactions. The main purpose of this research is to study the influence of the different categories of figurative logo designs on consumer response. Through two studies in three countries, this research sheds light on consumer logo preferences, by investigating the psychological properties of the figurativeness of logo design. Results showed that figurativeness is an essen...

  7. BOOK REVIEW: Relativistic Figures of Equilibrium

    Science.gov (United States)

    Mars, M.

    2009-08-01

    Compact fluid bodies in equilibrium under its own gravitational field are abundant in the Universe and a proper treatment of them can only be carried out using the full theory of General Relativity. The problem is of enormous complexity as it involves two very different regimes, namely the interior and the exterior of the fluid, coupled through the surface of the body. This problem is very challenging both from a purely theoretical point of view, as well as regarding the obtaining of realistic models and the description of their physical properties. It is therefore an excellent piece of news that the book 'Relativistic Figures of Equilibrium' by R Meinel, M Ansorg, A Kleinwächter, G Neugebauer and D Petroff has been recently published. This book approaches the topic in depth and its contents will be of interest to a wide range of scientists working on gravitation, including theoreticians in general relativity, mathematical physicists, astrophysicists and numerical relativists. This is an advanced book that intends to present some of the present-day results on this topic. The most basic results are presented rather succinctly, and without going into the details, of their derivations. Although primarily not intended to serve as a textbook, the presentation is nevertheless self-contained and can therefore be of interest both for experts on the field as well as for anybody wishing to learn more about rotating self-gravitating compact bodies in equilibrium. It should be remarked, however, that this book makes a rather strong selection of topics and concentrates fundamentally on presenting the main results obtained by the authors during their research in this field. The book starts with a chapter where the fundamental aspects of rotating fluids in equilibrium, including its thermodynamic properties, are summarized. Of particular interest are the so-called mass-shedding limit, which is the limit where the body is rotating so fast that it is on the verge of starting

  8. Central Hemodynamics and Arterial Stiffness in Systemic Sclerosis.

    Science.gov (United States)

    Bartoloni, Elena; Pucci, Giacomo; Cannarile, Francesca; Battista, Francesca; Alunno, Alessia; Giuliani, Marco; Cafaro, Giacomo; Gerli, Roberto; Schillaci, Giuseppe

    2016-12-01

    Although microvascular disease is a hallmark of systemic sclerosis (SSc), a higher prevalence of macrovascular disease and a poorer related prognosis have been reported in SSc than in the general population. The simultaneous assessment of prognostically relevant functional properties of larger and smaller arteries, and their effects on central hemodynamics, has never been performed in SSc using the state-of-the-art techniques. Thirty-four women with SSc (aged 61±15 years, disease duration 17±12 years, and blood pressure 123/70±18/11 mm Hg) and 34 healthy women individually matched by age and mean arterial pressure underwent the determination of carotid-femoral (aortic) and carotid-radial (upper limb) pulse wave velocity (a direct measure of arterial stiffness), aortic augmentation (a measure of the contribution of reflected wave to central pulse pressure), and aortobrachial pulse pressure amplification (brachial/aortic pulse pressure) through applanation tonometry (SphygmoCor). Patients and controls did not differ by carotid-femoral or carotid-radial pulse wave velocity. Aortic augmentation index corrected for a heart rate of 75 bpm (AIx@75) was higher in women with SSc (30.9±16% versus 22.2±12%; P=0.012). Patients also had a lower aortobrachial amplification of pulse pressure (1.22±0.18 versus 1.33±0.25; P=0.041). SSc was an independent predictor of AIx@75 (direct) and pulse pressure amplification (inverse). Among patients, age, mean arterial pressure, and C-reactive protein independently predicted carotid-femoral pulse wave velocity. Age and mean arterial pressure were the only predictors of AIx@75. Women with SSc have increased aortic augmentation and decreased pulse pressure amplification (both measures of the contribution of reflected wave to central waveform) but no changes in aortic or upper limb arterial stiffness. Microvascular involvement occurs earlier than large artery stiffening in SSc. © 2016 American Heart Association, Inc.

  9. Determination of the crystallite orientation distribution from direct pole figures

    International Nuclear Information System (INIS)

    Araujo Gomes, P.A.M. de.

    1977-01-01

    A method is described which allows to calculate the crystallite orientation distribution in polycrystalline material, from direct pole figures data of its crystallographic planes (Roe's Method). The programme was applied to (1010), (0002), (1011) and (1120) complete pole figures data for a commercial, thin sheet Zircaloy-4 tubing specimen. A semi-automatic Rigaku-Denki texture goniometer, which scans the reciprocal lattice sphere pointwise outputting the data in a punched tape, was used to obtain the pole figures. This is consistent with the results obtained through direct conclusion from the pole figures. (author)

  10. Masking interrupts figure-ground signals in V1.

    Science.gov (United States)

    Lamme, Victor A F; Zipser, Karl; Spekreijse, Henk

    2002-10-01

    In a backward masking paradigm, a target stimulus is rapidly (figure-ground segregation can be recorded. Here, we recorded from awake macaque monkeys, engaged in a task where they had to detect figures from background in a pattern backward masking paradigm. We show that the V1 figure-ground signals are selectively and fully suppressed at target-mask intervals that psychophysically result in the target being invisible. Initial response transients, signalling the features that make up the scene, are not affected. As figure-ground modulations depend on feedback from extrastriate areas, these results suggest that masking selectively interrupts the recurrent interactions between V1 and higher visual areas.

  11. Familiar shapes attract attention in figure-ground displays.

    Science.gov (United States)

    Nelson, Rolf A; Palmer, Stephen E

    2007-04-01

    We report five experiments that explore the effect of figure-ground factors on attention. We hypothesized that figural cues, such as familiar shape, would draw attention to the figural side in an attentional cuing task using bipartite figure-ground displays. The first two experiments used faces in profile as the familiar shape and found a perceptual advantage for targets presented on the meaningful side of the central contour in detection speed (Experiment 1) and discrimination accuracy (Experiment 2). The third experiment demonstrated the figural advantage in response time (RT) with nine other familiar shapes (including a sea horse, a guitar, a fir tree, etc.), but only when targets appeared in close proximity to the contour. A fourth experiment obtained a figural advantage in a discrimination task with the larger set of familiar shapes. The final experiment ruled out eye movements as a possible confounding factor by replicating the RT advantage for targets on the figural side of face displays when all trials containing eye movements were eliminated. The results are discussed in terms of ecological influences on attention, and are cast within the framework of Yantis and Jonides's hypothesis that attention is exogenously drawn to the onset of new perceptual objects. We argue that the figural side constitutes an "object" whereas the ground side does not, and that figural cues such as shape familiarity are effective in determining which areas represent objects.

  12. Surface reconstruction, figure-ground modulation, and border-ownership.

    Science.gov (United States)

    Jeurissen, Danique; Self, Matthew W; Roelfsema, Pieter R

    2013-01-01

    The Differentiation-Integration for Surface Completion (DISC) model aims to explain the reconstruction of visual surfaces. We find the model a valuable contribution to our understanding of figure-ground organization. We point out that, next to border-ownership, neurons in visual cortex code whether surface elements belong to a figure or the background and that this is influenced by attention. We furthermore suggest that there must be strong links between object recognition and figure-ground assignment in order to resolve the status of interior contours. Incorporation of these factors in neurocomputational models will further improve our understanding of surface reconstruction, figure-ground organization, and border-ownership.

  13. Rumsey and Walker_AMT_2016_Figure 2.xlsx

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figure summarizes uncertainty (error) in hourly gradient flux measurements by individual analyte. Flux uncertainty is derived from estimates of uncertainty in...

  14. 'Generalizability' of a radial-aortic transfer function for the derivation of central aortic waveform parameters.

    Science.gov (United States)

    Hope, Sarah A; Meredith, Ian T; Tay, David; Cameron, James D

    2007-09-01

    Arterial transfer functions (TFs) describe the relationship between the pressure waveform at different arterial sites. Generalized TFs are used to reconstruct central aortic waveforms from non-invasively obtained peripheral waveforms and have been promoted as potentially clinically useful. A limitation is the paucity of information on their 'generalizability' with no information existing on the number of subjects required to construct a satisfactory TF, nor is adequate prospective validation available. We therefore investigated the uniformity of radial-aortic TFs and prospectively estimated the capacity of a generalized TF to reconstruct individual central blood pressure parameters. Ninety-three subjects (64 male) were studied by simultaneous radial applanation and high-fidelity (Millar Mikro-tip catheter) direct measurement of central aortic BP during elective coronary procedures. Subjects were prospectively randomized to either a derivation or validation group. Increasing numbers of individual TFs from the derivation group were averaged to form a generalized TF. There was minimal change with greater than 20 TFs averaged. In the validation group, the error in most reconstructed parameters related to the absolute value of the directly measured parameter [systolic blood pressure (SBP) and pulse pressure, Pcentral aortic SBP and pulse pressure (negatively) and time to peak systole (positively) (all PInclusion of more than 20 individual TFs in the construction of a generalized TF does not improve 'generalizability'. There appear to be systematic errors in derived central pressure waveforms and derived aortic augmentation index is inaccurate compared to the directly measured value.

  15. The postprocessing techniques in renal artery reconstructions and clinical application with multidetector spiral CT angiography

    International Nuclear Information System (INIS)

    Yu Yuanxin; Liang Changhong; Zhang Zhonglin; Xie Shufei; Liu Yubao; Tang Xiangzhou

    2005-01-01

    Objective: To investigate the value and predominance for imaging postprocessing techniques of renal artery variation and lesions by multidetector spiral CT angiography. Methods: 51 patients with renal artery disease including 12 artery variation, 27 artery stenosis, 3 renal anenrysm, 3 thrombosis of renal artery and 3 dissecting aneurysm of renal artery by SSD, MIP and CPR were enrolled. The effectiveness of these imaging postprocessing methods was compared, 29 of them were confirmed by DSA and 3 by operation, others were checked by MRA and follow up. Results: All abnormalities and diseases were cleariy displayed. The specificity and sensitivity were 100% respectively. In the all imaging postprocessing techniques, MPR can clearly display the calcification of the arteries, stenosis, embolism, aneurysm but do not display the anatomy satisfactorily. MIP can not only clearly display the anatomy but display the different configurations. VR can display the artery figures but can not display the information of lumen of blood vessels. SSD can display the complex vessel anatomy but it was influenced by its threshold selection. CPR can spread and display directly the tortuous renal artery and measure the section area of stenosis. Conclusions: MSCTA is helpful to accurately display the renal artery variation and lesions. Both MIP and VR are the best choice to illustrate the renal artery abnormalities. And MPR and SSD are assistant in the diagnosis of' renal artery lesions. (authors)

  16. Methods and apparatus for radially compliant component mounting

    Science.gov (United States)

    Bulman, David Edward [Cincinnati, OH; Darkins, Jr., Toby George; Stumpf, James Anthony [Columbus, IN; Schroder, Mark S [Greenville, SC; Lipinski, John Joseph [Simpsonville, SC

    2012-03-27

    Methods and apparatus for a mounting assembly for a liner of a gas turbine engine combustor are provided. The combustor includes a combustor liner and a radially outer annular flow sleeve. The mounting assembly includes an inner ring surrounding a radially outer surface of the liner and including a plurality of axially extending fingers. The mounting assembly also includes a radially outer ring coupled to the inner ring through a plurality of spacers that extend radially from a radially outer surface of the inner ring to the outer ring.

  17. RADIALLY MAGNETIZED PROTOPLANETARY DISK: VERTICAL PROFILE

    International Nuclear Information System (INIS)

    Russo, Matthew; Thompson, Christopher

    2015-01-01

    This paper studies the response of a thin accretion disk to an external radial magnetic field. Our focus is on protoplanetary disks (PPDs), which are exposed during their later evolution to an intense, magnetized wind from the central star. A radial magnetic field is mixed into a thin surface layer, wound up by the disk shear, and pushed downward by a combination of turbulent mixing and ambipolar and ohmic drift. The toroidal field reaches much greater strengths than the seed vertical field that is usually invoked in PPD models, even becoming superthermal. Linear stability analysis indicates that the disk experiences the magnetorotational instability (MRI) at a higher magnetization than a vertically magnetized disk when both the effects of ambipolar and Hall drift are taken into account. Steady vertical profiles of density and magnetic field are obtained at several radii between 0.06 and 1 AU in response to a wind magnetic field B r ∼ (10 −4 –10 −2 )(r/ AU) −2 G. Careful attention is given to the radial and vertical ionization structure resulting from irradiation by stellar X-rays. The disk is more strongly magnetized closer to the star, where it can support a higher rate of mass transfer. As a result, the inner ∼1 AU of a PPD is found to evolve toward lower surface density. Mass transfer rates around 10 −8 M ⊙ yr −1 are obtained under conservative assumptions about the MRI-generated stress. The evolution of the disk and the implications for planet migration are investigated in the accompanying paper

  18. RADIALLY MAGNETIZED PROTOPLANETARY DISK: VERTICAL PROFILE

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Matthew [Department of Physics, University of Toronto, 60 St. George St., Toronto, ON M5S 1A7 (Canada); Thompson, Christopher [Canadian Institute for Theoretical Astrophysics, 60 St. George St., Toronto, ON M5S 3H8 (Canada)

    2015-11-10

    This paper studies the response of a thin accretion disk to an external radial magnetic field. Our focus is on protoplanetary disks (PPDs), which are exposed during their later evolution to an intense, magnetized wind from the central star. A radial magnetic field is mixed into a thin surface layer, wound up by the disk shear, and pushed downward by a combination of turbulent mixing and ambipolar and ohmic drift. The toroidal field reaches much greater strengths than the seed vertical field that is usually invoked in PPD models, even becoming superthermal. Linear stability analysis indicates that the disk experiences the magnetorotational instability (MRI) at a higher magnetization than a vertically magnetized disk when both the effects of ambipolar and Hall drift are taken into account. Steady vertical profiles of density and magnetic field are obtained at several radii between 0.06 and 1 AU in response to a wind magnetic field B{sub r} ∼ (10{sup −4}–10{sup −2})(r/ AU){sup −2} G. Careful attention is given to the radial and vertical ionization structure resulting from irradiation by stellar X-rays. The disk is more strongly magnetized closer to the star, where it can support a higher rate of mass transfer. As a result, the inner ∼1 AU of a PPD is found to evolve toward lower surface density. Mass transfer rates around 10{sup −8} M{sub ⊙} yr{sup −1} are obtained under conservative assumptions about the MRI-generated stress. The evolution of the disk and the implications for planet migration are investigated in the accompanying paper.

  19. Testicular artery arising from an aberrant right renal artery | Suluba ...

    African Journals Online (AJOL)

    This case report we discovered the rare variation of the origin of the right testicular artery arising from the right aberrant renal artery with double renal artery irrigating both left and right kidneys. These variations in the testicular arteries and renal arteries have implication to surgical procedures such as orchidopexy repair for ...

  20. Radial fractional Laplace operators and Hessian inequalities

    Science.gov (United States)

    Ferrari, Fausto; Verbitsky, Igor E.

    In this paper we deduce a formula for the fractional Laplace operator ( on radially symmetric functions useful for some applications. We give a criterion of subharmonicity associated with (, and apply it to a problem related to the Hessian inequality of Sobolev type: ∫Rn |(u| dx⩽C∫Rn -uFk[u] dx, where Fk is the k-Hessian operator on Rn, 1⩽kFerrari et al. [5] contains the extremal functions for the Hessian Sobolev inequality of X.-J. Wang (1994) [15]. This is proved using logarithmic convexity of the Gaussian ratio of hypergeometric functions which might be of independent interest.

  1. Convex and Radially Concave Contoured Distributions

    Directory of Open Access Journals (Sweden)

    Wolf-Dieter Richter

    2015-01-01

    Full Text Available Integral representations of the locally defined star-generalized surface content measures on star spheres are derived for boundary spheres of balls being convex or radially concave with respect to a fan in Rn. As a result, the general geometric measure representation of star-shaped probability distributions and the general stochastic representation of the corresponding random vectors allow additional specific interpretations in the two mentioned cases. Applications to estimating and testing hypotheses on scaling parameters are presented, and two-dimensional sample clouds are simulated.

  2. On radial flow between parallel disks

    International Nuclear Information System (INIS)

    Wee, A Y L; Gorin, A

    2015-01-01

    Approximate analytical solutions are presented for converging flow in between two parallel non rotating disks. The static pressure distribution and radial component of the velocity are developed by averaging the inertial term across the gap in between parallel disks. The predicted results from the first approximation are favourable to experimental results as well as results presented by other authors. The second approximation shows that as the fluid approaches the center, the velocity at the mid channel slows down which is due to the struggle between the inertial term and the flowrate. (paper)

  3. Validation of Noninvasive MOEMS-Assisted Measurement System Based on CCD Sensor for Radial Pulse Analysis

    Directory of Open Access Journals (Sweden)

    Rolanas Dauksevicius

    2013-04-01

    Full Text Available Examination of wrist radial pulse is a noninvasive diagnostic method, which occupies a very important position in Traditional Chinese Medicine. It is based on manual palpation and therefore relies largely on the practitioner’s subjective technical skills and judgment. Consequently, it lacks reliability and consistency, which limits practical applications in clinical medicine. Thus, quantifiable characterization of the wrist pulse diagnosis method is a prerequisite for its further development and widespread use. This paper reports application of a noninvasive CCD sensor-based hybrid measurement system for radial pulse signal analysis. First, artery wall deformations caused by the blood flow are calibrated with a laser triangulation displacement sensor, following by the measurement of the deformations with projection moiré method. Different input pressures and fluids of various viscosities are used in the assembled artificial blood flow system in order to test the performance of laser triangulation technique with detection sensitivity enhancement through microfabricated retroreflective optical element placed on a synthetic vascular graft. Subsequently, the applicability of double-exposure whole-field projection moiré technique for registration of blood flow pulses is considered: a computational model and representative example are provided, followed by in vitro experiment performed on a vascular graft with artificial skin atop, which validates the suitability of the technique for characterization of skin surface deformations caused by the radial pulsation.

  4. Duplicated middle cerebral artery

    Science.gov (United States)

    Perez, Jesus; Machado, Calixto; Scherle, Claudio; Hierro, Daniel

    2009-01-01

    Duplicated middle cerebral artery (DMCA) is an anomalous vessel arising from the internal carotid artery. The incidence DMCA is relatively law, and an association between this anomaly and cerebral aneurysms has been documented. There is a controversy whether DMCA may have perforating arteries. This is an important fact to consider in aneurysm surgery. We report the case of a 34-year-old black woman who suffered a subarachnoid hemorrhage and the angiography a left DMCA, and an aneurysm in an inferior branch of the main MCA. The DMCA and the MCA had perforating arteries. The aneurysm was clipped without complications. The observation of perforating arteries in our patient confirms that the DMCA may have perforating arteries. This is very important to be considered in cerebral aneurysms surgery. Moreover, the DMCA may potentially serve as a collateral blood supply to the MCA territory in cases of MCA occlusion. PMID:22140405

  5. Correlation of ICME Magnetic Fields at Radially Aligned Spacecraft

    Science.gov (United States)

    Good, S. W.; Forsyth, R. J.; Eastwood, J. P.; Möstl, C.

    2018-03-01

    The magnetic field structures of two interplanetary coronal mass ejections (ICMEs), each observed by a pair of spacecraft close to radial alignment, have been analysed. The ICMEs were observed in situ by MESSENGER and STEREO-B in November 2010 and November 2011, while the spacecraft were separated by more than 0.6 AU in heliocentric distance, less than 4° in heliographic longitude, and less than 7° in heliographic latitude. Both ICMEs took approximately two days to travel between the spacecraft. The ICME magnetic field profiles observed at MESSENGER have been mapped to the heliocentric distance of STEREO-B and compared directly to the profiles observed by STEREO-B. Figures that result from this mapping allow for easy qualitative assessment of similarity in the profiles. Macroscale features in the profiles that varied on timescales of one hour, and which corresponded to the underlying flux rope structure of the ICMEs, were well correlated in the solar east-west and north-south directed components, with Pearson's correlation coefficients of approximately 0.85 and 0.95, respectively; microscale features with timescales of one minute were uncorrelated. Overall correlation values in the profiles of one ICME were increased when an apparent change in the flux rope axis direction between the observing spacecraft was taken into account. The high degree of similarity seen in the magnetic field profiles may be interpreted in two ways. If the spacecraft sampled the same region of each ICME ( i.e. if the spacecraft angular separations are neglected), the similarity indicates that there was little evolution in the underlying structure of the sampled region during propagation. Alternatively, if the spacecraft observed different, nearby regions within the ICMEs, it indicates that there was spatial homogeneity across those different regions. The field structure similarity observed in these ICMEs points to the value of placing in situ space weather monitors well upstream of the

  6. Popliteal artery entrapment syndrome.

    LENUS (Irish Health Repository)

    O'Leary, D P

    2010-01-01

    Popliteal artery entrapment syndrome is a rare abnormality of the anatomical relationship between the popliteal artery and adjacent muscles or fibrous bands in the popliteal fossa. The following is a case report of a 19 year old female, in whom popliteal artery entrapment syndrome was diagnosed, and successfully treated surgically. A review of literature is also presented and provides details on how PAES is classified, diagnosed both clinically and radiologically, and treated surgically.

  7. Normal variation of hepatic artery

    International Nuclear Information System (INIS)

    Kim, Inn; Nam, Myung Hyun; Rhim, Hyun Chul; Koh, Byung Hee; Seo, Heung Suk; Kim, Soon Yong

    1987-01-01

    This study was an analyses of blood supply of the liver in 125 patients who received hepatic arteriography and abdominal aortography from Jan. 1984 to Dec. 1986 at the Department of Radiology of Hanyang University Hospital. A. Variations in extrahepatic arteries: 1. The normal extrahepatic artery pattern occurred in 106 of 125 cases (84.8%) ; Right hepatic and left hepatic arteries arising from the hepatic artery proper and hepatic artery proper arising from the common hepatic artery. 2. The most common type of variation of extrahepatic artery was replaced right hepatic artery from superior mesenteric artery: 6 of 125 cases (4.8%). B. Variations in intrahepatic arteries: 1. The normal intrahepatic artery pattern occurred in 83 of 125 cases (66.4%). Right hepatic and left hepatic arteries arising from the hepatic artery proper and middle hepatic artery arising from lower portion of the umbilical point of left hepatic artery. 2. The most common variation of intrahepatic arteries was middle hepatic artery. 3. Among the variation of middle hepatic artery; Right, middle and left hepatic arteries arising from the same location at the hepatic artery proper was the most common type; 17 of 125 cases (13.6%)

  8. Renal Branch Artery Stenosis

    DEFF Research Database (Denmark)

    Andersson, Zarah; Thisted, Ebbe; Andersen, Ulrik Bjørn

    2017-01-01

    Renovascular hypertension is a common cause of pediatric hypertension. In the fraction of cases that are unrelated to syndromes such as neurofibromatosis, patients with a solitary stenosis on a branch of the renal artery are common and can be diagnostically challenging. Imaging techniques...... that perform well in the diagnosis of main renal artery stenosis may fall short when it comes to branch artery stenosis. We report 2 cases that illustrate these difficulties and show that a branch artery stenosis may be overlooked even by the gold standard method, renal angiography....

  9. Imaging the vertebral artery

    Energy Technology Data Exchange (ETDEWEB)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Davies, John R.; Weissberg, Peter L. [Addenbrooke' s Hospital and University of Cambridge, Division of Cardiovascular Medicine, Cambridge (United Kingdom); Gillard, Jonathan H. [Addenbrooke' s Hospital and University of Cambridge, Department of Radiology, Cambridge (United Kingdom); Addenbrooke' s Hospitald, University Department of Radiology, Cambridge (United Kingdom)

    2005-07-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  10. Imaging the vertebral artery

    International Nuclear Information System (INIS)

    Tay, Keng Yeow; U-King-Im, Jean Marie; Trivedi, Rikin A.; Higgins, Nicholas J.; Cross, Justin J.; Antoun, Nagui M.; Davies, John R.; Weissberg, Peter L.; Gillard, Jonathan H.

    2005-01-01

    Although conventional intraarterial digital subtraction angiography remains the gold standard method for imaging the vertebral artery, noninvasive modalities such as ultrasound, multislice computed tomographic angiography and magnetic resonance angiography are constantly improving and are playing an increasingly important role in diagnosing vertebral artery pathology in clinical practice. This paper reviews the current state of vertebral artery imaging from an evidence-based perspective. Normal anatomy, normal variants and a number of pathological entities such as vertebral atherosclerosis, arterial dissection, arteriovenous fistula, subclavian steal syndrome and vertebrobasilar dolichoectasia are discussed. (orig.)

  11. Congenital coronary artery fistula

    International Nuclear Information System (INIS)

    Oh, Yeon Hee; Kim, Hong; Zeon, Seoc Kil; Suh, Soo Jhi

    1986-01-01

    Congenital coronary artery fistula (CCAF) is communication of a coronary artery or its main branch with one of the atria or ventricles, the coronary sinus, the superior vena cava, or the pulmonary artery. In Korean peoples, only 4 cases of the CCAF were reported as rare as worldwide and authors want to report another case of CCAF, confirmed by operation. 10-year-old girl shows a fistula between sinus node artery of the right coronary artery and right atrium on root aortogram with left-to-right shunt and Qp/Qs=1.58, in which simple ligation of the sinus node artery from right coronary artery was performed. All of the 5 Korean CCAF (4 were previously reported and 1 of authors) were originated from right coronary artery, and of which 4 were opening into right ventricle and 1 of authors were into right atrium. Associated cardiac anomaly was noted in only 1 case as single coronary artery. Ages were from 9 months of age to 10 years old and no adult left case were found. 3 were female and 2 were male patients.

  12. Figurative framing: Shaping public discourse through metaphor, hyperbole and irony

    NARCIS (Netherlands)

    Burgers, C.F.; Konijn, E.A.; Steen, G.J.

    2016-01-01

    Framing is an important concept in communication, yet many framing studies set out to develop frames relevant to only one issue. We expand framing theory by introducing figurative framing. We posit that figurative language types like metaphor, hyperbole and irony are important in shaping public

  13. 16 CFR Figure 1 to Part 1203 - Anatomical Planes

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Anatomical Planes 1 Figure 1 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 1 Figure 1 to Part 1203—Anatomical Planes ER10MR98.001 ...

  14. Figure 1. Associations between pre-ART clinical and laboratory ...

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. Figure 1. Associations between pre-ART clinical and laboratory characteristics with subsequent TB-IRIS events. Figure 1. Associations between pre-ART clinical and laboratory characteristics with subsequent TB-IRIS events.

  15. 16 CFR Figure 6 to Part 1203 - Field of Vision

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Field of Vision 6 Figure 6 to Part 1203 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT SAFETY ACT REGULATIONS SAFETY STANDARD FOR BICYCLE HELMETS Pt. 1203, Fig. 6 Figure 6 to Part 1203—Field of Vision ER10MR98.006 ...

  16. Figurative framing : Shaping public discourse through metaphor, hyperbole and irony

    NARCIS (Netherlands)

    Burgers, C.; Konijn, E.A.; Steen, G.J.

    2016-01-01

    Framing is an important concept in communication, yet many framing studies set out to develop frames relevant to only one issue. We expand framing theory by introducing figurative framing. We posit that figurative language types like metaphor, hyperbole and irony are important in shaping public

  17. A new principle of figure-ground segregation : The accentuation

    NARCIS (Netherlands)

    Pinna, Baingio; Reeves, Adam; Koenderink, Jan; van Doorn, Andrea; Deiana, Katia

    2018-01-01

    The problem of perceptual organization was studied by Gestalt psychologists in terms of figure-ground segregation. In this paper we explore a new principle of figure-ground segregation: accentuation. We demonstrate the effectiveness of accentuation relative to other Gestalt principles, and also

  18. Figure output program for JFT-2M experimental data

    International Nuclear Information System (INIS)

    Miura, Yukitoshi; Mori, Masahiro; Matsuda, Toshiaki; Takada, Susumu.

    1991-11-01

    The software for the figure output of JFT-2M experimental data is reported. Since the configuration of a figure is determined by some easy input parameters, then any format of each experimental output is configured freely by this software. (author)

  19. Estimating the Volumes of Solid Figures with Curved Surfaces.

    Science.gov (United States)

    Cohen, Donald

    1991-01-01

    Several examples of solid figures that calculus students can use to exercise their skills at estimating volume are presented. Although these figures are bounded by surfaces that are portions of regular cylinders, it is interesting to note that their volumes can be expressed as rational numbers. (JJK)

  20. Distinguishing between Realistic and Fantastical Figures in Iran

    Science.gov (United States)

    Davoodi, Telli; Corriveau, Kathleen H.; Harris, Paul L.

    2016-01-01

    Children in the United States come to distinguish historical from fictional story figures between the ages of 3 and 5 years, guided by the plausibility of the story events surrounding the figure (Corriveau, Kim, Schwalen, & Harris, 2009; Woolley & Cox, 2007). However, U.S. children vary in their reactions to stories that include…

  1. 50 CFR Figure 10 to Part 223 - Flounder TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Flounder TED 10 Figure 10 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 10 Figure 10 to Part 223—Flounder TED EC01JY91.056 [5...

  2. 50 CFR Figure 3 to Part 223 - Matagorda TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Matagorda TED 3 Figure 3 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 3 Figure 3 to Part 223—Matagorda TED EC01JY91.047 [52...

  3. The Use and Abuse of Human Figure Drawings.

    Science.gov (United States)

    Motta, Robert W.; And Others

    1993-01-01

    Notes widespread use of human figure drawings to describe and predict psychological functioning. Reviews data-based studies on figure drawings and concludes that there is little support for their validity or for their use as devices to assess personality, behavior, emotion, or intellectual functioning. Presents ease of administration and anecdotal…

  4. Spherical radial basis functions, theory and applications

    CERN Document Server

    Hubbert, Simon; Morton, Tanya M

    2015-01-01

    This book is the first to be devoted to the theory and applications of spherical (radial) basis functions (SBFs), which is rapidly emerging as one of the most promising techniques for solving problems where approximations are needed on the surface of a sphere. The aim of the book is to provide enough theoretical and practical details for the reader to be able to implement the SBF methods to solve real world problems. The authors stress the close connection between the theory of SBFs and that of the more well-known family of radial basis functions (RBFs), which are well-established tools for solving approximation theory problems on more general domains. The unique solvability of the SBF interpolation method for data fitting problems is established and an in-depth investigation of its accuracy is provided. Two chapters are devoted to partial differential equations (PDEs). One deals with the practical implementation of an SBF-based solution to an elliptic PDE and another which describes an SBF approach for solvi...

  5. Asymptotic Solutions of Serial Radial Fuel Shuffling

    Directory of Open Access Journals (Sweden)

    Xue-Nong Chen

    2015-12-01

    Full Text Available In this paper, the mechanism of traveling wave reactors (TWRs is investigated from the mathematical physics point of view, in which a stationary fission wave is formed by radial fuel drifting. A two dimensional cylindrically symmetric core is considered and the fuel is assumed to drift radially according to a continuous fuel shuffling scheme. A one-group diffusion equation with burn-up dependent macroscopic coefficients is set up. The burn-up dependent macroscopic coefficients were assumed to be known as functions of neutron fluence. By introducing the effective multiplication factor keff, a nonlinear eigenvalue problem is formulated. The 1-D stationary cylindrical coordinate problem can be solved successively by analytical and numerical integrations for associated eigenvalues keff. Two representative 1-D examples are shown for inward and outward fuel drifting motions, respectively. The inward fuel drifting has a higher keff than the outward one. The 2-D eigenvalue problem has to be solved by a more complicated method, namely a pseudo time stepping iteration scheme. Its 2-D asymptotic solutions are obtained together with certain eigenvalues keff for several fuel inward drifting speeds. Distributions of the neutron flux, the neutron fluence, the infinity multiplication factor kinf and the normalized power are presented for two different drifting speeds.

  6. [Comparison of chemical quality characteristics between radial striations and non-radial striations in tuberous root of Rehmannia glutinosa].

    Science.gov (United States)

    Xie, Cai-Xia; Zhang, Miao; Li, Ya-Jing; Geng, Xiao-Tong; Wang, Feng-Qing; Zhang, Zhong-Yi

    2017-11-01

    An HPLC method was established to determine the contents of catalpol, acteoside, rehmaionoside A, rehmaionoside D, leonuride in three part of Rehmanni glutinosa in Beijing No.1 variety R. glutinosa during the growth period, This method, in combination with its HPLC fingerprint was used to evaluate its overall quality characteristics.The results showed that:① the content of main components of R. glutinosa varied in different growth stages ;② there was a great difference of the content of main components between theradial striations and the non-radial striations; ③ the two sections almost have the same content distribution of catalpol, acteoside and rehmaionoside D; ④the content of rehmaionoside A in non-radial striations was higher than that in radial striations,while the content of leonuride in radial striations was higher than that in non-radial striations.; ⑤the HPLC fingerprint of radial striations, non-radial striations and whole root tuber were basically identical, except for the big difference in the content of chemical components. The result of clustering displayed that the radial striations, non-radial striations, and whole root were divided into two groups. In conclusion, there was a significant difference in the quality characteristics of radial striations and non-radial striations of R. glutinosa. This research provides a reference for quality evaluation and geoherbalism of R. glutinosa. Copyright© by the Chinese Pharmaceutical Association.

  7. Percutaneous transluminal angioplasty of infrarenal arteries in intermittent claudication

    DEFF Research Database (Denmark)

    Henriksen, L O; Jørgensen, B; Holstein, P E

    1988-01-01

    Percutaneous transluminal angioplasty was performed on 55 iliac and 31 femoropopliteal arteries in 71 patients with intermittent claudication (23 women, 48 men). The two-year patency rate was 80% after iliac and 41% after femoropopliteal angioplasty. In 17 femoropopliteal cases with lesions greater...... than or equal to 5 cm the 2-year patency rate was only 32%, but the corresponding figure for shorter lesions was 53%. Complicating haematoma appeared in 10% of the cases and the arterial state deteriorated in one patient. There was no distal embolization. Percutaneous transluminal angioplasty...

  8. Acesso radial em intervenções coronarianas percutâneas: panorama atual brasileiro Acceso radial en intervenciones coronarias percutáneas: panorama actual brasileño Radial approach in percutaneous coronary interventions: current status in Brazil

    Directory of Open Access Journals (Sweden)

    Pedro Beraldo de Andrade

    2011-04-01

    fue comparado al femoral (2,5% versus 3,6%, p BACKGROUND: Although the radial approach offers an unquestionable result in terms of reduction of vascular complications and occurrence of severe bleeding in comparison to the femoral approach, so far it has only been used in few centers which elected it as the preferential access. OBJECTIVE: To evaluate the current status of percutaneous coronary interventions in Brazil, as regards the use of the radial approach. METHODS: Analysis of data spontaneously recorded in Central Nacional de Intervenções Cardiovasculares - CENIC (National Center for Cardiovascular Interventions from 2005 to 2008, in a total of 83,376 procedures. RESULTS: The radial approach was used in 12.6% of the procedures performed, and the femoral approach, in 84.3%. The remaining 3.1% corresponded to brachial artery dissection or puncture. With a success rate of 97.5%, the choice of the radial approach was associated with a significant reduction of vascular complications in comparison to the femoral approach (2.5% versus 3.6 %, p < 0.0001. CONCLUSION: The radial approach remains uncommonly used in Brazil, and this is possibly explained by the lack of training programs, uncertainties regarding the learning curve, and the lack of large-scale studies corroborating the benefits demonstrated to date.

  9. A theory of self-organized zonal flow with fine radial structure in tokamak

    Science.gov (United States)

    Zhang, Y. Z.; Liu, Z. Y.; Xie, T.; Mahajan, S. M.; Liu, J.

    2017-12-01

    The (low frequency) zonal flow-ion temperature gradient (ITG) wave system, constructed on Braginskii's fluid model in tokamak, is shown to be a reaction-diffusion-advection system; it is derived by making use of a multiple spatiotemporal scale technique and two-dimensional (2D) ballooning theory. For real regular group velocities of ITG waves, two distinct temporal processes, sharing a very similar meso-scale radial structure, are identified in the nonlinear self-organized stage. The stationary and quasi-stationary structures reflect a particular feature of the poloidal group velocity. The equation set posed to be an initial value problem is numerically solved for JET low mode parameters; the results are presented in several figures and two movies that show the spatiotemporal evolutions as well as the spectrum analysis—frequency-wave number spectrum, auto power spectrum, and Lissajous diagram. This approach reveals that the zonal flow in tokamak is a local traveling wave. For the quasi-stationary process, the cycle of ITG wave energy is composed of two consecutive phases in distinct spatiotemporal structures: a pair of Cavitons growing and breathing slowly without long range propagation, followed by a sudden decay into many Instantons that carry negative wave energy rapidly into infinity. A spotlight onto the motion of Instantons for a given radial position reproduces a Blob-Hole temporal structure; the occurrence as well as the rapid decay of Caviton into Instantons is triggered by zero-crossing of radial group velocity. A sample of the radial profile of zonal flow contributed from 31 nonlinearly coupled rational surfaces near plasma edge is found to be very similar to that observed in the JET Ohmic phase [J. C. Hillesheim et al., Phys. Rev. Lett. 116, 165002 (2016)]. The theory predicts an interior asymmetric dipole structure associated with the zonal flow that is driven by the gradients of ITG turbulence intensity.

  10. Figure-Ground Processing: A Reassessment of Gelb and Granit.

    Science.gov (United States)

    Nelson, Rolf; Hebda, Nicholas

    2018-03-01

    In 1923, Adhemar Gelb and Ragnar Granit, two prominent researchers in early Gestalt perceptual theory, reported a lower threshold for detection of a target (a small colored dot) on the ground region of an image than on an adjacent figural region. Although their results had a wide influence on the understanding of figure-ground perception, they are at odds with more recent investigations in which figural regions appear to have a processing advantage over ground regions. The two present studies replicated Gelb and Granit's experiment using a similar figure-ground stimulus albeit with a two-alternative forced choice procedure rather than their original method of adjustment. Experiment 1 found that, contrary to Gelb and Granit's findings, a detection advantage was found for the figural over the ground region. Experiment 2 indicated that explicit contours might have played a role in detection.

  11. Lower region: a new cue for figure-ground assignment.

    Science.gov (United States)

    Vecera, Shaun P; Vogel, Edward K; Woodman, Geoffrey F

    2002-06-01

    Figure-ground assignment is an important visual process; humans recognize, attend to, and act on figures, not backgrounds. There are many visual cues for figure-ground assignment. A new cue to figure-ground assignment, called lower region, is presented: Regions in the lower portion of a stimulus array appear more figurelike than regions in the upper portion of the display. This phenomenon was explored, and it was demonstrated that the lower-region preference is not influenced by contrast, eye movements, or voluntary spatial attention. It was found that the lower region is defined relative to the stimulus display, linking the lower-region preference to pictorial depth perception cues. The results are discussed in terms of the environmental regularities that this new figure-ground cue may reflect.

  12. Human figure drawings by children with Duchenne's muscular dystrophy.

    Science.gov (United States)

    Pope-Grattan, M M; Burnett, C N; Wolfe, C V

    1976-02-01

    Seventy-two human figure drawings by forty-three patients who had a diagnosis of Duchenne's muscular dystrophy were examined. The study includes a description of these human figure drawings according to eleven emotional indicators and according to directionality quadrants. When the human figure drawings were used as a projective tool, four personality traits of some of the children were identified: physical inadequacy, immaturity, body anxiety, and insecurity. Both the emotional indicators and the quadrant in which the figures appeared were examined in relation to stages of the disease process to see if the human figure drawings of the children might reflect more stress and anxiety at a particular stage of the disease. Suggestions for improvements and recommendations for future study are given.

  13. Patients undergoing PCI from the femoral route by default radial operators are at high risk of vascular access-site complications.

    Science.gov (United States)

    Rafie, Ihsan M; Uddin, Muez M; Ossei-Gerning, Nicholas; Anderson, Richard A; Kinnaird, Timothy D

    2014-02-01

    Radial artery (RA) access for PCI has a lower incidence of vascular access-site (VAS) complications than the femoral artery (FA) approach. However, even for default radial operators certain patients are intervened upon from the FA. We examined the demographics and incidence of VAS complications when default radial operators resort to the FA for PCI. The demographics and VAS complications were compared by access site retrospectively for all PCI cases performed by default radial operators (n=1,392). A modified ACUITY trial definition of major VAS complication was used. FA puncture occurred in 25.2% (351/1,392) of cases. Patients were more likely to be female, older and weigh less than patients undergoing PCI from the RA. The FA procedure was likely to be more complex with larger sheaths, more left main stem, graft and multivessel intervention, and there was a greater proportion of emergency cases. Despite increased case complexity, glycoprotein inhibitors were used less frequently in femoral cases (26.5% vs. 36.8%, prisk factors for access-site bleeding are disproportionately high in the population requiring FA puncture by default radial operators, and as a result such patients have a high rate of vascular access-site complications.

  14. Hand-arm vibration syndrome with distal brachial artery occlusion

    Directory of Open Access Journals (Sweden)

    Vladyslava Bazylevska

    2017-01-01

    Full Text Available Abstract             Hand-arm vibration syndrome (HAVS is a complex disorder of the peripheral extremities that is associated with occupational or recreational exposure to hand-transmitted vibration. Digital artery occlusion in HAVS is a common finding; however, proximal involvement is less likely.  We present a case of HAVS with the initial presentation of acute limb ischemia and with thrombus burden extending from the distal brachial artery and into the ulnar and radial arteries. To our knowledge, no case of HAVS syndrome of similar severity has been previously described. This case emphasizes the potential dangers of HAVS and the necessity for proper prophylactic interventions at the workplace.

  15. Incremental Value of Increasing Number of Arterial Grafts: The Effect of Diabetes Mellitus.

    Science.gov (United States)

    Schwann, Thomas A; El Hage Sleiman, Abdul Karim M; Yammine, Maroun B; Tranbaugh, Robert F; Engoren, Milo; Bonnell, Mark R; Habib, Robert H

    2018-06-01

    Multiarterial coronary grafting with two arterial grafts leads to improved survival compared with conventional single artery based on left internal thoracic artery to left anterior descending artery and saphenous vein grafts. We investigated whether extending arterial grafting to three or more arterial grafts further improves survival, and whether such a benefit is modified by diabetes mellitus. We analyzed 15-year coronary artery bypass graft surgery mortality data in 11,931 patients (age 64.3 ± 10.5 years; 3,484 women [29.2%]; 4,377 [36.7%] with diabetes mellitus) derived from three US institutions (1994 to 2011). All underwent primary isolated left internal thoracic artery to left anterior descending artery grafting with at least two grafts: one artery (n = 6,782; 56.9%); two arteries (n = 3,678; 30.8%); or three or more arteries (n = 1,471; 12.3%). Long-term survival was estimated by Kaplan-Meier methods. Propensity score matching and comprehensive covariate adjustment (Cox regression) were used to derive long-term risk-adjusted hazard ratio (HR) with 95% confidence interval (CI) for increasing number of arterial grafts in the overall cohort and for diabetes and no-diabetes cohorts. Radial artery (94%) and right internal thoracic artery (6%) were used as additional arterial grafts. Multivariate analysis in all patients showed that diabetes was associated with decreased survival (HR 1.43, 95% CI: 1.34 to 53), whereas increasing number of arterial grafts was associated with decreased mortality (one artery HR 1.0 [reference]; two arteries HR 0.87, 95% CI: 0.80 to 0.95; and three arteries HR 0.83, 95% CI: 0.72 to 0.95). Pairwise comparisons also showed an incremental benefit of additional arterial grafts: two arteries versus one artery, HR 0.89 (95% CI: 0.80 to 0.98); and three arteries versus one artery, HR 0.80 (95% CI: 0.68 to 0.94). A three-artery versus two-artery survival advantage trend was also noted, but was not significant in either the overall study

  16. Thrombosed persistent median artery causing carpal tunnel syndrome associated with bifurcated median nerve: A case report

    International Nuclear Information System (INIS)

    Salter, M.; Sinha, N. R.; Szmigielski, W.

    2011-01-01

    Background: Carpal tunnel syndrome is a sporadically occurring abnormality due to compression of median nerve. It is exceedingly rare for it to be caused by thrombosis of persistent median artery. Case Report: A forty two year old female was referred for ultrasound examination due to ongoing wrist pain, not relived by pain killers and mild paraesthesia on the radial side of the hand. High resolution ultrasound and Doppler revealed a thrombosed persistent median artery and associated bifurcated median nerve. The thrombus resolved on treatment with anticoagulants. Conclusions: Ultrasound examination of the wrist when done for patients with carpal tunnel syndrome should preferably include looking for persistent median artery and its patency. (authors)

  17. Development of a polymer endovascular prosthesis and its implantation in porcine arteries

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); H.M.M. van Beusekom (Heleen); D.S. van Ingen Schenau; R.A. Huijts; J.C.H. Schuurbiers (Johan); W.J. de Klein (Willem); P.W.J.C. Serruys (Patrick); P.D. Verdouw (Pieter); W.J. van der Giessen (Wim)

    1992-01-01

    textabstractA polyethylene-terephthalate braided mesh stent has been developed for application in the (coronary) arterial tree. In vitro measurements showed that the radial pressure delivered by this device was in the same range as that of a stainless steel stent. Hysteresis-like behavior, however,

  18. Femoral Access PCI in a Default Radial Center Identifies High-Risk Patients With Poor Outcomes.

    Science.gov (United States)

    Uddin, Muezz; Bundhoo, Shantu; Mitra, Rito; Ossei-Gerning, Nicholas; Morris, Keith; Anderson, Richard; Kinnaird, Tim

    2015-10-01

    Increasingly the trans-radial route (TRR) is preferred over the trans-femoral route (TFR) for PCI. However, even in high volume default TRR centers a cohort of patients undergo TFR PCI. We examined the demographics, procedural characteristics, and outcomes of patients undergoing PCI via the TF. The patient demographics, procedural data, and outcomes of 5,379 consecutive patients undergoing PCI at a default radial center between 2009 and 2012 were examined. Major bleeding (MB) was classified by ACUITY and BARC definitions. A total of 559 (10.4%) patients underwent PCI via the TFR and 4,820 patients via the TRR (89.6%). Baseline variables associated with TFR were shock, previous CABG, chronic total occlusion intervention, rotablation/laser use, female sex, and renal failure. Sixty-five patients of the TFR cohort (11.6%) experienced MB with 27 (41.5%) being access site related. MB was significantly more frequent than in the radial cohort. The variables independently associated with MB in the TFR cohort were renal failure, acute presentation, shock, and age. In the TFR, patients with MB mortality was high at 30 days (17.2% vs 2.6% for no MB, P default radial PCI center 10% of patients undergo PCI via the femoral artery. These patients have high baseline bleeding risk and undergo complex interventions. As a result the incidence of major bleeding, transfusion and death are high. Alternative strategies are required to optimize outcomes in this select group. © 2015, Wiley Periodicals, Inc.

  19. Hemodynamics alter arterial low-density lipoprotein metabolism

    International Nuclear Information System (INIS)

    Warty, V.S.; Calvo, W.J.; Berceli, S.A.; Pham, S.M.; Durham, S.J.; Tanksale, S.K.; Klein, E.C.; Herman, I.M.; Borovetz, H.S.

    1989-01-01

    We have investigated the role of hemodynamic factors on low-density lipoprotein transport and metabolism in the intact arterial wall. Freshly excised canine carotid blood vessels were exposed to well-defined pulsatile flow in vitro for continuous periods up to 20 hours. We chose to impose the following hemodynamic conditions on our test carotid arteries: normotension, hypertension (at physiologic flow conditions), and hypertension coupled with elevated flow of canine serum perfusate. In several experiments the effect of endothelial denudation was examined in carotid arteries exposed to normotensive pulsatile flow. A trapped ligand method was used for quantitating low-density lipoprotein uptake and metabolism in the arterial wall. The distribution of both intact and degraded low-density lipoprotein fractions was determined from measurements of radiolabelled low-density lipoprotein activity within thin radial sections of perfused arteries. Our results suggest that both hypertensive hemodynamic simulations exacerbate the uptake of low-density lipoprotein within the arterial wall (by a factor of three to nine). The percentage of low-density lipoprotein that undergoes irreversible degradation falls from 41% under normotensive conditions to below 30% when hypertensive conditions are imposed, indicating that degradative processes are not proportionally elevated with the accelerated influx. A similar pattern is observed for deendothelialized vessels

  20. Quantitative determination of arterial wall mechanics with pulse oximetric finger plethysmography.

    Science.gov (United States)

    Kato, R; Sato, J; Iuchi, T; Higuchi, Y

    1999-10-30

    The plethysmographic wave of pulse oximetry reflects arterial pulsation at the fingertip. Since arterial pressure and the pulsatile component of the arterial cross section represent the input and output of the fingertip arterial system, respectively, arterial wall mechanics may be delineated from their relationship. We aimed to construct a mathematical model of the fingertip arterial wall from the relationship between the plethysmographic wave and arterial pressure. The pulse oximetric plethysmographic signal at the forefinger and pressure at the ipsilateral radial artery were measured. Employing the data, simple mathematical models with one to four mechanical elements were tested in terms of the goodness of fit and the physiological implications. The determined model was applied to the data obtained during administration of vasoactive agents in anesthetized patients. The mathematical model suited for describing arterial wall mechanics was a four-element, two-compartment model. The two compartments represent passive mechanical and active contractile properties, respectively. In the application of the model to the anesthetized patients, the vasoactive agents produced changes in the model parameters that implied mechanical alterations in the arterial wall. These findings suggest the benefit of the four-element, two-compartment model in analyzing peripheral vascular wall mechanics influenced by various stimuli in intensive care and anesthesia.

  1. Pulmonary artery aneurysm

    African Journals Online (AJOL)

    Enrique

    Introduction. Pulmonary artery aneurysms are a rare finding in general radiological practice. The possible causes are myriad and diverse in pathophysiolo- gy. Patients with post-stenotic dilata- tion of the main pulmonary artery usually present fairly late with insidi- ous cardiorespiratory symptoms. Diagnosis requires ...

  2. MR accuracy and arthroscopic incidence of meniscal radial tears

    Energy Technology Data Exchange (ETDEWEB)

    Magee, Thomas; Shapiro, Marc; Williams, David [Department of Radiology, Neuroimaging Institute, 27 East Hibiscus Blvd., Melbourne, FL 32901 (United States)

    2002-12-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  3. MR accuracy and arthroscopic incidence of meniscal radial tears

    International Nuclear Information System (INIS)

    Magee, Thomas; Shapiro, Marc; Williams, David

    2002-01-01

    A meniscal radial tear is a vertical tear that involves the inner meniscal margin. The tear is most frequent in the middle third of the lateral meniscus and may extend outward in any direction. We report (1) the arthroscopic incidence of radial tears, (2) MR signs that aid in the detection of radial tears and (3) our prospective accuracy in detection of radial tears. Design and patients. Three musculoskeletal radiologists prospectively read 200 consecutive MR examinations of the knee that went on to arthroscopy by one orthopedic surgeon. MR images were assessed for location and MR characteristics of radial tears. MR criteria used for diagnosis of a radial tear were those outlined by Tuckman et al.: truncation, abnormal morphology and/or lack of continuity or absence of the meniscus on one or more MR images. An additional criterion used was abnormal increased signal in that area on fat-saturated proton density or T2-weighted coronal and sagittal images. Prospective MR readings were correlated with the arthroscopic findings.Results. Of the 200 consecutive knee arthroscopies, 28 patients had radial tears reported arthroscopically (14% incidence). MR readings prospectively demonstrated 19 of the 28 radial tears (68% sensitivity) when the criteria for diagnosis of a radial tear were truncation or abnormal morphology of the meniscus. With the use of the additional criterion of increased signal in the area of abnormal morphology on fat-saturated T2-weighted or proton density weighted sequences, the prospective sensitivity was 25 of 28 radial tears (89% sensitivity). There were no radial tears described in MR reports that were not demonstrated on arthroscopy (i.e., there were no false positive MR readings of radial tears in these 200 patients). Radial tears are commonly seen at arthroscopy. There was a 14% incidence in this series of 200 patients who underwent arthroscopy. Prospective detection of radial tears was 68% as compared with arthroscopy when the criteria as

  4. BILATERAL DUPLICATION OF RENAL ARTERIES

    OpenAIRE

    Prajkta A Thete; Mehera Bhoir; M.V.Ambiye

    2014-01-01

    Routine dissection of a male cadaver revealed the presence of bilateral double renal arteries. On the right side the accessory renal artery originated from the abdominal aorta just above the main renal artery. On the left side the accessory renal artery originated from the abdominal aorta about 1 cm above the main renal artery. Knowledge of the variations of renal vascular anatomy has importance in exploration and treatment of renal trauma, renal transplantation, renal artery embolization, su...

  5. Figure-ground segregation: A fully nonlocal approach.

    Science.gov (United States)

    Dimiccoli, Mariella

    2016-09-01

    We present a computational model that computes and integrates in a nonlocal fashion several configural cues for automatic figure-ground segregation. Our working hypothesis is that the figural status of each pixel is a nonlocal function of several geometric shape properties and it can be estimated without explicitly relying on object boundaries. The methodology is grounded on two elements: multi-directional linear voting and nonlinear diffusion. A first estimation of the figural status of each pixel is obtained as a result of a voting process, in which several differently oriented line-shaped neighborhoods vote to express their belief about the figural status of the pixel. A nonlinear diffusion process is then applied to enforce the coherence of figural status estimates among perceptually homogeneous regions. Computer simulations fit human perception and match the experimental evidence that several cues cooperate in defining figure-ground segregation. The results of this work suggest that figure-ground segregation involves feedback from cells with larger receptive fields in higher visual cortical areas. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Figure-ground segmentation can occur without attention.

    Science.gov (United States)

    Kimchi, Ruth; Peterson, Mary A

    2008-07-01

    The question of whether or not figure-ground segmentation can occur without attention is unresolved. Early theorists assumed it can, but the evidence is scant and open to alternative interpretations. Recent research indicating that attention can influence figure-ground segmentation raises the question anew. We examined this issue by asking participants to perform a demanding change-detection task on a small matrix presented on a task-irrelevant scene of alternating regions organized into figures and grounds by convexity. Independently of any change in the matrix, the figure-ground organization of the scene changed or remained the same. Changes in scene organization produced congruency effects on target-change judgments, even though, when probed with surprise questions, participants could report neither the figure-ground status of the region on which the matrix appeared nor any change in that status. When attending to the scene, participants reported figure-ground status and changes to it highly accurately. These results clearly demonstrate that figure-ground segmentation can occur without focal attention.

  7. Radial propagation of microturbulence in tokamaks

    International Nuclear Information System (INIS)

    Garbet, X.; Laurent, L.; Roubin, J.P.; Samain, A.

    1992-01-01

    Energy confinement time in tokamaks exhibits a clear dependence on global plasma parameters. This is not the case for transport coefficients; their dependence on local plasma parameters cannot be precisely established. The aim of the present paper is to give a possible explanation of this behaviour; turbulence propagates radially because of departure from cylindrical geometry. This implies that the turbulence level at a given point and hence transport coefficients are not only functions of local plasma parameters. A quantitative estimate of the propagation velocity is derived from a Lagrangian formalism. Two cases are considered: the effect of toroidicity and the effect of non linear mode-mode coupling. The consequences of this model are discussed. This process does not depend on the type of instability. For the sake of simplicity only electrostatic perturbations are considered

  8. Radial expansion for spinning conformal blocks

    CERN Document Server

    Costa, Miguel S.; Penedones, João; Trevisani, Emilio

    2016-07-12

    This paper develops a method to compute any bosonic conformal block as a series expansion in the optimal radial coordinate introduced by Hogervorst and Rychkov. The method reduces to the known result when the external operators are all the same scalar operator, but it allows to compute conformal blocks for external operators with spin. Moreover, we explain how to write closed form recursion relations for the coefficients of the expansions. We study three examples of four point functions in detail: one vector and three scalars; two vectors and two scalars; two spin 2 tensors and two scalars. Finally, for the case of two external vectors, we also provide a more efficient way to generate the series expansion using the analytic structure of the blocks as a function of the scaling dimension of the exchanged operator.

  9. Hydrostatic radial bearing of centrifugal pump

    International Nuclear Information System (INIS)

    Skalicky, A.

    1976-01-01

    A hydrostatic radial pump is described characterized by the fact that part of the medium off-taken from delivery is used as a lubricating medium. Two additional bodies are placed alongside a hydrostatic bearing with coils in between them and the pump shaft; the coils have an opposite pitch. The feed channel for the hydrostatic bearing pocket is linked to delivery. The coil outlets are connected to the pump suction unit. Two rotating coils placed alongside the hydrostatic bearing will considerably simplify the communication channel design and reduce the dependence on the pump shaft deflections. The addition of another rotating coil in the close vicinity of the pump shaft or directly on the shaft further increases the efficiency. The bearing can be used in designing vertical circulating pumps for the cooling circuits of nuclear reactors. (J.B.)

  10. The radial velocity variations in IC 418

    International Nuclear Information System (INIS)

    Mendez, R.H.; Verga, A.D.

    1981-01-01

    The observations presented are part of a search for spectral and radial velocity variations among central stars of planetary nebulae and include the following new data: 1) Weak, previously undetected C III emissions are visible at 4056, 4186, 4516, 5270 and 5826 A. The famous unidentified emissions at 4485 and 4503 A were also found. 2) The He I absorptions at 4471 and 5875 A are blue-shifted relative to the nebular emissions. The same happens with Hsub(delta) and Hsub(γ), although in this case the shift can be at least partly attributed to blends with the strong He II absorptions, which are estimated to contribute about one half of the equivalent width at Hsub(delta) and Hsub(γ). 3) O III 5592 and C IV 5801, 5811 are also found in absorption. (Auth.)

  11. Doubly stochastic radial basis function methods

    Science.gov (United States)

    Yang, Fenglian; Yan, Liang; Ling, Leevan

    2018-06-01

    We propose a doubly stochastic radial basis function (DSRBF) method for function recoveries. Instead of a constant, we treat the RBF shape parameters as stochastic variables whose distribution were determined by a stochastic leave-one-out cross validation (LOOCV) estimation. A careful operation count is provided in order to determine the ranges of all the parameters in our methods. The overhead cost for setting up the proposed DSRBF method is O (n2) for function recovery problems with n basis. Numerical experiments confirm that the proposed method not only outperforms constant shape parameter formulation (in terms of accuracy with comparable computational cost) but also the optimal LOOCV formulation (in terms of both accuracy and computational cost).

  12. Bilateral triple renal arteries

    International Nuclear Information System (INIS)

    Pestemalci, Turan; Yildiz, Yusuf Zeki; Yildirim, Mehmet; Mavi, Ayfer; Gumusburun, Erdem

    2009-01-01

    Knowledge of the variations of the renal artery has grown in importance with increasing numbers of renal transplants, vascular reconstructions and various surgical and radio logic techniques being performed in recent years. We report the presence of bilateral triple renal arteries, discovered on routine dissection of a male cadaver. On the right side, one additional renal artery originated from the abdominal aorta (distributed to superior pole of the kidney) and one other originated from the right common iliac artery (distributed to lower pole of the kidney). On the left side, both additional renal arteries originated from the abdominal aorta. Our observation has been compared with variations described in the literature and their clinical importance has been emphasized. (author)

  13. Occlusion of Heubner's artery

    International Nuclear Information System (INIS)

    Sato, Manabu; Kidooka, Minoru

    1982-01-01

    A case of occlusion of the left Heubner's artery in a right-handed, 51-year-old man is reported. Cardinal clinical features were transient right hemiparesis and mental disturbance, especially intellectual defect. Low density areas were found at CT in the globus pallidus, putamen, anterior limb of the internal capsule and a part of the caudate nucleus. It is well known that the occlusion of the Heubner's artery causes transient motor paresis of upper extremity on the contralaterl side. However, in the case where the Heubner's artery is remarkably well developed when compared with the medial striate arteries as was the case in this patient, it should be noted that the occlusion of the Heubner's artery may well causes grave mental disturbance, in addition. (author)

  14. Complications of operative treatment of injuries of peripheral arteries.

    Science.gov (United States)

    Velinovic, M M; Davidovic, B L; Lotina, I S; Vranes, R M; Djukic, L P; Arsov, J V; Ristic, V M; Kocica, J M; Petrovic, L P

    2000-06-01

    In 1991 and 1992, a total of 97 patients with 106 peripherial arterial injuries underwent surgery at the Institute for Cardiovascular Diseases, Clinical Centre of Serbia. Civilian injuries accounted for 53 (54.6%) patients (94.3% males, age range: 16-63 yr, mean: 35.2), and 44 patients had war injuries (93.2% males, age range: 19-61 yr, mean: 34.8). The injuries affected the superfitial femoral artery in 31 (29.24%); the popliteal artery in 28 (26.41%); the brachial artery in 17 (16.04%); the posterior tibial artery in 6 (5.66%); the axillary artery in 5 (4.72%); the anterior tibial artery in 5 (4.72%); the tibioperoneal trunk in 4 (3. 77%); the common femoral artery in 4 (3.77%); the external iliac artery in 2 (1.89%); the profound femoral artery in 2 (1.89%); the radial artery in 1 (0.94%); and ulnar artery in 1 (0.94%).A total of 98 reconstructive procedures were used to treat these patients. Graft interposition carried out in 50 (51.02%); by pass in 25 (25. 51%); end-to-end anastomosis in 9 (9.18%); suture in 8 (8.16%); ligation in 4 (4.08%); and patch-angioplasty in 2 (2.04%). Primary reconstruction of injured arteries was performed in 72.2% and secondary repair in 27.8% cases. Infection developed in 51 (52.57%) patients, and it was significantly (P<0.05) more common in the war injuries (70.45%) and in secondary repairs (88.89%). The presence of associated lesions (69.56%) was also correlated with a greater rate of infection. Amputation was necessary in 21 (21.65%) of our patients, and was significantly (P<0.05) more often performed after secondary (44.44%) than primary operations (12.86%) and in the presence of associated injuries (32.61%).

  15. Radial extension of drift waves in presence of velocity profiles

    International Nuclear Information System (INIS)

    Sen, S.; Weiland, J.

    1994-01-01

    The effect of a radially varying poloidal velocity field on the recently found radially extended toroidal drift waves is investigated analytically. The role of velocity curvature (υ φ '') is found to have robust effects on the radial model structure of the mode. For a positive value of the curvature (Usually found in the H-mode edges) the radial model envelope, similar to the sheared slab case, becomes fully outgoing. The mode is therefore stable. On the other hand, for a negative value of the curvature (usually observed in the L-mode edges) all the characteristics of conventional drift waves return back. The radial mode envelope reduces to a localized Gaussian shape and the mode is therefore unstable again for typical (magnetic) shear values in tokamaks. Velocity shear (υ φ ??) on the other hand is found to have rather insignificant role both in determining the radial model structure and stability

  16. Radial stability of anisotropic strange quark stars

    Energy Technology Data Exchange (ETDEWEB)

    Arbañil, José D.V.; Malheiro, M., E-mail: jose.arbanil@upn.pe, E-mail: malheiro@ita.br [ITA—Instituto Tecnológico de Aeronáutica—Departamento de Física, 12228-900, São José dos Campos, São Paulo (Brazil)

    2016-11-01

    The influence of the anisotropy in the equilibrium and stability of strange stars is investigated through the numerical solution of the hydrostatic equilibrium equation and the radial oscillation equation, both modified from their original version to include this effect. The strange matter inside the quark stars is described by the MIT bag model equation of state. For the anisotropy two different kinds of local anisotropic σ = p {sub t} − p {sub r} are considered, where p {sub t} and p {sub r} are respectively the tangential and the radial pressure: one that is null at the star's surface defined by p {sub r} ( R ) = 0, and one that is nonnull at the surface, namely, σ {sub s} = 0 and σ {sub s} {sub ≠} {sub 0}. In the case σ {sub s} = 0, the maximum mass value and the zero frequency of oscillation are found at the same central energy density, indicating that the maximum mass marks the onset of the instability. For the case σ {sub s} {sub ≠} {sub 0}, we show that the maximum mass point and the zero frequency of oscillation coincide in the same central energy density value only in a sequence of equilibrium configurations with the same value of σ {sub s} . Thus, the stability star regions are determined always by the condition dM / d ρ {sub c} {sub >} {sub 0} only when the tangential pressure is maintained fixed at the star surface's p {sub t} ( R ). These results are also quite important to analyze the stability of other anisotropic compact objects such as neutron stars, boson stars and gravastars.

  17. Figure ground discrimination in age-related macular degeneration.

    Science.gov (United States)

    Tran, Thi Ha Chau; Guyader, Nathalie; Guerin, Anne; Despretz, Pascal; Boucart, Muriel

    2011-03-01

    To investigate impairment in discriminating a figure from its background and to study its relation to visual acuity and lesion size in patients with neovascular age-related macular degeneration (AMD). Seventeen patients with neovascular AMD and visual acuity Figure/ground segregation is impaired in patients with AMD. A white space surrounding an object is sufficient to improve the object's detection and to facilitate figure/ground segregation. These results may have practical applications to the rehabilitation of the environment in patients with AMD.

  18. Energy in Sweden: Facts and figures 2009; Energilaeget 2009

    Energy Technology Data Exchange (ETDEWEB)

    2009-12-15

    Energy in Sweden 2009: Facts and figures contains the tabular for most of the diagrams in the main publication (STEM-ET--2009-30). These data consist primarily of the results of the Agency's processing of basic data from Statistics Sweden. Statistics are of preliminary character for the two last published years (2007 and 2008). Breakdowns into certain types of fuels vary somewhat depending on whether preliminary or final data is used. Please note that the figures have been rounded up or down, therefore totals do not always comply with the sum of individual figures

  19. A New Filtering Algorithm Utilizing Radial Velocity Measurement

    Institute of Scientific and Technical Information of China (English)

    LIU Yan-feng; DU Zi-cheng; PAN Quan

    2005-01-01

    Pulse Doppler radar measurements consist of range, azimuth, elevation and radial velocity. Most of the radar tracking algorithms in engineering only utilize position measurement. The extended Kalman filter with radial velocity measureneut is presented, then a new filtering algorithm utilizing radial velocity measurement is proposed to improve tracking results and the theoretical analysis is also given. Simulation results of the new algorithm, converted measurement Kalman filter, extended Kalman filter are compared. The effectiveness of the new algorithm is verified by simulation results.

  20. Vitreous veils and radial lattice in Marshall syndrome.

    Science.gov (United States)

    Brubaker, Jacob W; Mohney, Brian G; Pulido, Jose S; Babovic-Vuksanovic, Dusica

    2008-12-01

    To report the findings of membranous vitreous veils and radial lattice in a child with Marshall syndrome. Observational case report. Retrospective review of medical records and fundus photograph of a 6-year-old boy with Marshall syndrome. Vitreoretinal findings were significant for bilateral membranous vitreous veils and radial lattice degeneration. This case demonstrates the occurrence of vitreous veils and radial lattice degeneration in patients with Marshall syndrome.

  1. Figural properties are prioritized for search under conditions of uncertainty: Setting boundary conditions on claims that figures automatically attract attention.

    Science.gov (United States)

    Peterson, Mary A; Mojica, Andrew J; Salvagio, Elizabeth; Kimchi, Ruth

    2017-01-01

    Nelson and Palmer (2007) concluded that figures/figural properties automatically attract attention, after they found that participants were faster to detect/discriminate targets appearing where a portion of a familiar object was suggested in an otherwise ambiguous display. We investigated whether these effects are truly automatic and whether they generalize to another figural property-convexity. We found that Nelson and Palmer's results do generalize to convexity, but only when participants are uncertain regarding when and where the target will appear. Dependence on uncertainty regarding target location/timing was also observed for familiarity. Thus, although we could replicate and extend Nelson and Palmer's results, our experiments showed that figures do not automatically draw attention. In addition, our research went beyond Nelson and Palmer's, in that we were able to separate figural properties from perceived figures. Because figural properties are regularities that predict where objects lie in the visual field, our results join other evidence that regularities in the environment can attract attention. More generally, our results are consistent with Bayesian theories in which priors are given more weight under conditions of uncertainty.

  2. Pseudarthrosis of radial shaft with dislocation of heads of radial and ulnar bones (case report

    Directory of Open Access Journals (Sweden)

    M. E. Puseva

    2013-01-01

    Full Text Available The authors presented a rare clinical case - the injury of forearm complicated by the formation of the pseudarthrosis of the radial shaft in combination with old dislocation of heads the radius and ulna. The differentiated approach to the choice of surgical tactics was proposed, which consists of several consistent stages: taking free autotransplant from the crest of iliac bone, resection of pseudarthrosis of radius with replacement of the bone defect by the graft for restoration of anatomic length, conducting combined strained osteosynthesis and elimination of dislocation of a head of radial and ulnar bones by transosseous osteosynthesis. The chosen treatment strategy allowed to restore the anatomy and function of the upper extremity.

  3. Effects of orientation on Rey complex figure performance.

    Science.gov (United States)

    Ferraro, F Richard; Grossman, Jennifer; Bren, Amy; Hoverson, Allysa

    2002-10-01

    An experiment was performed that examined the impact of stimulus orientation on performance on the Rey complex figure. A total of 48 undergraduates (24 men, 24 women) were randomly assigned to one of four Rey figure orientation groups (0 degrees, 90 degrees, 180 degrees, and 270 degrees ). Participants followed standard procedures for the Rey figure, initially copying it in whatever orientation group they were assigned to. Next, all participants performed a 15-20 min lexical decision experiment, used as a filler task. Finally, and unbeknownest to them, participants were asked to recall as much of the figure as they could. As expected, results revealed a main effect of Task (F = 83.92, p orientation was not significant, nor did orientation interact with task (Fs .57). The results are important from an applied setting, especially if testing conditions are less than optimal and a fixed stimulus position is not possible (e.g., testing at the bedside).

  4. Rumsey and Walker_AMT_2016_Figure 1.xlsx

    Data.gov (United States)

    U.S. Environmental Protection Agency — Figure summarizes diurnal profiles of uncertainty in the chemical gradient and transfer velocity measurements from which fluxes are calculated. This dataset is...

  5. R&D figures 'distorted' by defence spending

    CERN Multimedia

    Coghlan, A

    1990-01-01

    A report published by the House of Lords Select Committee on Science and Technology, claims that government figures for R&D spending are misleading. They apparently include military projects that are more concerned with product development than original research.

  6. Figure/ground analogy for integrated sustainability & planning

    CSIR Research Space (South Africa)

    Beyers, C

    2006-12-01

    Full Text Available This article proposes a figure ground analogy as alternative way of conceptually integrating sustainability and planning. Within this framework planners are challenged to creatively consider planning practice and thought against a background...

  7. Figuring out the Statistics of the ICC World Cup 2011

    Science.gov (United States)

    Shiwalkar, Jyoti P.; Deshpande, M. N.

    2013-01-01

    This paper deals with the analysis of cricket match results from the ICC World Cup 2011. We believe that such data provide good material for interesting classroom exercises. (Contains 7 tables and 1 figure.)

  8. Temporal dynamics of figure-ground segregation in human vision.

    Science.gov (United States)

    Neri, Peter; Levi, Dennis M

    2007-01-01

    The segregation of figure from ground is arguably one of the most fundamental operations in human vision. Neural signals reflecting this operation appear in cortex as early as 50 ms and as late as 300 ms after presentation of a visual stimulus, but it is not known when these signals are used by the brain to construct the percepts of figure and ground. We used psychophysical reverse correlation to identify the temporal window for figure-ground signals in human perception and found it to lie within the range of 100-160 ms. Figure enhancement within this narrow temporal window was transient rather than sustained as may be expected from measurements in single neurons. These psychophysical results prompt and guide further electrophysiological studies.

  9. A search asymmetry reversed by figure-ground assignment.

    Science.gov (United States)

    Humphreys, G W; Müller, H

    2000-05-01

    We report evidence demonstrating that a search asymmetry favoring concave over convex targets can be reversed by altering the figure-ground assignment of edges in shapes. Visual search for a concave target among convex distractors is faster than search for a convex target among concave distractors (a search asymmetry). By using shapes with ambiguous local figure-ground relations, we demonstrated that search can be efficient (with search slopes around 10 ms/item) or inefficient (with search slopes around 30-40 ms/item) with the same stimuli, depending on whether edges are assigned to concave or convex "figures." This assignment process can operate in a top-down manner, according to the task set. The results suggest that attention is allocated to spatial regions following the computation of figure-ground relations in parallel across the elements present. This computation can also be modulated by top-down processes.

  10. Figures of Merit Guiding Research on Organic Solar Cells

    KAUST Repository

    Kirchartz, Thomas; Kaienburg, Pascal; Baran, Derya

    2018-01-01

    these criteria considering thermodynamic limits, their correlation to photocurrent and photovoltage, and effects on the fill factor. Each criterion is quantified by a figure of merit (FOM) that directly relates to device performance. To ensure a wide

  11. Figures6&7_Tables2&3

    Data.gov (United States)

    U.S. Environmental Protection Agency — This file contains three netCDF formatted files containing simulation model results used to produce Figures 6 and 7 and tables 3 and 4. These data can be accessed...

  12. Self-Esteem and Children's Human Figure Drawings

    Science.gov (United States)

    Dalby, J. Thomas; Vale, Helen L.

    1977-01-01

    One hundred and fifteen students in Grade 5 made human figure drawings which were compared with their scores on the Coopersmith Self-esteem Inventory and on teachers' ratings of the students' self-esteem. (Author)

  13. Numerical simulation of liquid-metal-flows in radial-toroidal-radial bends

    International Nuclear Information System (INIS)

    Molokov, S.; Buehler, L.

    1993-09-01

    Magnetohydrodynamic flows in a U-bend and right-angle bend are considered with reference to the radial-toroidal-radial concept of a self-cooled liquid-metal blanket. The ducts composing bends have rectangular cross-section. The applied magnetic field is aligned with the toroidal duct and perpendicular to the radial ones. At high Hartmann number the flow region is divided into cores and boundary layers of different types. The magnetohydrodynamic equations are reduced to a system of partial differential equations governing wall electric potentials and the core pressure. The system is solved numerically by two different methods. The first method is iterative with iteration between wall potential and the core pressure. The second method is a general one for the solution of the core flow equations in curvilinear coordinates generated by channel geometry and magnetic field orientation. Results obtained are in good agreement. They show, that the 3D-pressure drop of MHD flows in a U-bend is not a critical issue for blanket applications. (orig./HP) [de

  14. Fuel radial design using Path Relinking; Diseno radial de combustible usando Path Relinking

    Energy Technology Data Exchange (ETDEWEB)

    Campos S, Y. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The present work shows the obtained results when implementing the combinatory optimization technique well-known as Path Re linking (Re-linkage of Trajectories), to the problem of the radial design of nuclear fuel assemblies, for boiling water reactors (BWR Boiling Water Reactor by its initials in English), this type of reactors is those that are used in the Laguna Verde Nucleo electric Central, Veracruz. As in any other electric power generation plant of that make use of some fuel to produce heat and that it needs each certain time (from 12 to 14 months) to make a supply of the same one, because this it wears away or it burns, in the nucleolectric plants to this activity is denominated fuel reload. In this reload different activities intervene, among those which its highlight the radial and axial designs of fuel assemblies, the patterns of control rods and the multi cycles study, each one of these stages with their own complexity. This work was limited to study in independent form the radial design, without considering the other activities. These phases are basic for the fuel reload design and of reactor operation strategies. (Author)

  15. Noise destroys feedback enhanced figure-ground segmentation but not feedforward figure-ground segmentation

    Science.gov (United States)

    Romeo, August; Arall, Marina; Supèr, Hans

    2012-01-01

    Figure-ground (FG) segmentation is the separation of visual information into background and foreground objects. In the visual cortex, FG responses are observed in the late stimulus response period, when neurons fire in tonic mode, and are accompanied by a switch in cortical state. When such a switch does not occur, FG segmentation fails. Currently, it is not known what happens in the brain on such occasions. A biologically plausible feedforward spiking neuron model was previously devised that performed FG segmentation successfully. After incorporating feedback the FG signal was enhanced, which was accompanied by a change in spiking regime. In a feedforward model neurons respond in a bursting mode whereas in the feedback model neurons fired in tonic mode. It is known that bursts can overcome noise, while tonic firing appears to be much more sensitive to noise. In the present study, we try to elucidate how the presence of noise can impair FG segmentation, and to what extent the feedforward and feedback pathways can overcome noise. We show that noise specifically destroys the feedback enhanced FG segmentation and leaves the feedforward FG segmentation largely intact. Our results predict that noise produces failure in FG perception. PMID:22934028

  16. Brand logo design: Examining consumer responses to figurativeness

    OpenAIRE

    Machado, J. C.; Vacas-Carvalho, Leonor; Costa, P.; Torres, A.

    2013-01-01

    In a previous investigation, aimed at studying brand identity preferences in a merger context, researchers found the most preferred logos are figurative ones. Additionally, results suggested the aesthetic appeal of the logo significantly influences consumers’ identity choices. These results find support in logo strategy literature. The main purpose of this study is to investigate more thoroughly the influence of logo design characteristics, and particularly of figurativeness, o...

  17. Figure-ground: history and practice of a planning technique

    OpenAIRE

    Hebbert, M.

    2016-01-01

    Figure-ground plans show the footprints of buildings and the pattern of unbuilt voids in urban space. Compared historically they reveal the erosion of the public realm over time and provide an analytical basis for tissue repair. The paper traces the communicative power of figure-ground technique to its roots in gestalt psychology, and follows its revival from Colin Rowe’s studio at Cornell through to controversies in post-reunification Berlin. The impact of computerisation is discussed and th...

  18. 50 CFR Figure 4 to Part 223 - Georgia TED

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 7 2010-10-01 2010-10-01 false Georgia TED 4 Figure 4 to Part 223 Wildlife and Fisheries NATIONAL MARINE FISHERIES SERVICE, NATIONAL OCEANIC AND ATMOSPHERIC ADMINISTRATION, DEPARTMENT OF COMMERCE MARINE MAMMALS THREATENED MARINE AND ANADROMOUS SPECIES Pt. 223, Fig. 4 Figure 4 to Part 223—Georgia TED EC01JY91.048 [52 FR...

  19. Attention and competition in figure-ground perception.

    Science.gov (United States)

    Peterson, Mary A; Salvagio, Elizabeth

    2009-01-01

    What are the roles of attention and competition in determining where objects lie in the visual field, a phenomenon known as figure-ground perception? In this chapter, we review evidence that attention and other high-level factors such as familiarity affect figure-ground perception, and we discuss models that implement these effects. Next, we consider the Biased Competition Model of Attention in which attention is used to resolve the competition for neural representation between two nearby stimuli; in this model the response to the stimulus that loses the competition is suppressed. In the remainder of the chapter we discuss recent behavioral evidence that figure-ground perception entails between-object competition in which the response to the shape of the losing competitor is suppressed. We also describe two experiments testing whether more attention is drawn to resolve greater figure-ground competition, as would be expected if the Biased Competition Model of Attention extends to figure-ground perception. In these experiments we find that responses to targets on the location of a losing strong competitor are slowed, consistent with the idea that the location of the losing competitor is suppressed, but responses to targets on the winning competitor are not speeded, which is inconsistent with the hypothesis that attention is used to resolve figure-ground competition. In closing, we discuss evidence that attention can operate by suppression as well as by facilitation.

  20. Figurativeness in the Sense of Distraction (Studies by Lithuanian Authors

    Directory of Open Access Journals (Sweden)

    Laimutė Monginaitė

    2017-04-01

    Full Text Available The phenomenon of the sense of distraction and the feature of figurativeness in it are analysed with the help of phenomenological description, the concept of sense of Juozas Mureika and the conception of imagination of Kristupas Sabolius. The position is followed that the acts of sense and the being of those existing found in them cannot be known in a purely rational way. Knowing is reached with intuitive insights. The experiencing of distraction is approached as one of the norms or intentions of consciousness. The sense of distraction is acknowledged to be a basic value becoming more and more important in a modern stressful life. The article indicates that the intentional beings of the sense of distraction are expressed in really various human activities and are distinguished with mono-subjectivity and unrepeatable feeling. Figurativeness is perceived as the result of imaginary, creative activity of the imagination and aesthetical quality. The peculiarities of the formation of figurativeness are revealed through the phenomenological description of imagination by Sabolius. Four features of the act of visualisation, determining the quality of figurativeness, are emphasized: intentionality, power of transformation, relation with emotions and the symbolism of the image. The conclusion is made that figurativeness, being the result of the creative act (visualisation of imagination, appears as aesthetical quality or the ensemble of qualities. Figurativeness sharpens the sense of distraction and calls the wave of new experiences.

  1. Local figure-ground cues are valid for natural images.

    Science.gov (United States)

    Fowlkes, Charless C; Martin, David R; Malik, Jitendra

    2007-06-08

    Figure-ground organization refers to the visual perception that a contour separating two regions belongs to one of the regions. Recent studies have found neural correlates of figure-ground assignment in V2 as early as 10-25 ms after response onset, providing strong support for the role of local bottom-up processing. How much information about figure-ground assignment is available from locally computed cues? Using a large collection of natural images, in which neighboring regions were assigned a figure-ground relation by human observers, we quantified the extent to which figural regions locally tend to be smaller, more convex, and lie below ground regions. Our results suggest that these Gestalt cues are ecologically valid, and we quantify their relative power. We have also developed a simple bottom-up computational model of figure-ground assignment that takes image contours as input. Using parameters fit to natural image statistics, the model is capable of matching human-level performance when scene context limited.

  2. Renal artery stenosis

    International Nuclear Information System (INIS)

    Desberg, A.; Paushter, D.M.; Lammert, G.K.; Hale, J.; Troy, R.; Novic, A.; Nally, J. Jr.

    1989-01-01

    Renal artery disease is a potentially correctable cause of hypertension. Previous studies have suggested the utility of duplex sonography in accurately detecting and grading the severity of renal artery stenosis. The purpose of this paper is to evaluate color flow Doppler for this use. Forty-three kidneys were examined by color-flow Doppler and conventional duplex sampling in patients with suspected renovascular hypertension or those undergoing aortography for unrelated reasons. Doppler tracings were obtained from the renal arteries and aorta with calculation of the renal aortic ratio (RAR) and resistive index (RI). Results of Doppler sampling with color flow guidance were compared with aortograms in a blinded fashion

  3. Coronary artery aneurysms

    Energy Technology Data Exchange (ETDEWEB)

    Koischwitz, D.; Harder, T.; Schuppan, U.; Thurn, P.

    1982-04-01

    Seven saccular coronary artery aneurysms have been demonstrated in the course of 1452 selective coronary artery angiograms. In six patients they were arterio-sclerotic; in one patient the aneurysm must have been congenital or of mycotic-embolic origin. The differential diagnosis between true aneurysms and other causes of vascular dilatation is discussed. Coronary artery aneurysms have a poor prognosis because of the possibility of rupture with resultant cardiac tamponade, or the development of thrombo-embolic myocardial infarction. These aneurysms can only be diagnosed by means of coronary angiography and require appropriate treatment.

  4. Vertebrobasilar Artery Occlusion

    Directory of Open Access Journals (Sweden)

    Schoen, Jessica

    2011-05-01

    Full Text Available The presentation of vertebrobasilar artery occlusion varies with the cause of occlusion and location of ischemia. This often results in delay in diagnosis. Areas of the brain supplied by the posterior circulation are difficult to visualize and usually require angiography or magnetic resonance imaging. Intravenous thrombolysis and local-intra arterial thrombolysis are the most common treatment approaches used. Recanalization of the occluded vessel significantly improves morbidity and mortality. Here we present a review of the literature and a case of a patient with altered mental status caused by vertebrobasilar artery occlusion. [West J Emerg Med. 2011;12(2:233-239.

  5. Selective excitation of higher-radial-order Laguerre-Gaussian beams using a solid-state digital laser

    CSIR Research Space (South Africa)

    Bell, Teboho

    2017-01-01

    Full Text Available Filter (LF) was introduced to only transmit 1064 nm and block the 808 nm pump. The laser beam was transmitted out of the cavity through an output coupler mirror (M3 on Figure 1) and was 1:1 relay imaged using two 125 mm lenses (L3 and L4) to a Photon...; Published December 30, 2016 Citation: Bell T, Ngcobo S (2016) Selective Excitation of Higher-radial-order Laguerre-Gaussian Beams Using a Solid-state Digital Laser. J Laser Opt Photonics 3: 144. doi: 10.4172/2469-410X.1000144 Copyright: © 2016 Bell T, et...

  6. Design of radial reinforcement for prestressed concrete containments

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Shen, E-mail: swang@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States); Munshi, Javeed A., E-mail: jamunshi@bechtel.com [Bechtel Power Corporation, 5275 Westview Drive, BP2-2C3, Frederick, MD 21703 (United States)

    2013-02-15

    Highlights: ► A rigorous formulae is proposed to calculate radial stress within prestressed concrete containments. ► The proposed method is validated by finite element analysis in an illustrative practical example. ► A partially prestressed condition is more critical than a fully prestressed condition for radial tension. ► Practical design consideration is provided for detailing of radial reinforcement. -- Abstract: Nuclear containments are critical components for safety of nuclear power plants. Failure can result in catastrophic safety consequences as a result of leakage of radiation. Prestressed concrete containments have been used in large nuclear power plants with significant design internal pressure. These containments are generally reinforced with prestressing tendons in the circumferential (hoop) and meridional (vertical) directions. The curvature effect of the tendons introduces radial tensile stresses in the concrete shell which are generally neglected in the design of such structures. It is assumed that such tensile radial stresses are small as such no radial reinforcement is provided for this purpose. But recent instances of significant delaminations in Crystal River Unit 3 in Florida have elevated the need for reevaluation of the radial tension issue in prestressed containment. Note that currently there are no well accepted industry standards for design and detailing of radial reinforcement. This paper discusses the issue of radial tension in prestressed cylindrical and dome shaped structures and proposes formulae to calculate radial stresses. A practical example is presented to illustrate the use of the proposed method which is then verified by using state of art finite element analysis. This paper also provides some practical design consideration for detailing of radial reinforcement in prestressed containments.

  7. Potential in using elemental concentrations in radial increments of old growth eastern red cedar to examine the chemical history of the environment

    International Nuclear Information System (INIS)

    Guyette, R.; McGinnes, E.A. Jr.

    1987-01-01

    Research examines the potential of utilizing elemental concentrations in the wood of eastern red cedar (Juniperus virginiana L.) to make inferences about past changes in atmospheric and site chemistry. Crossdated growth increments from live trees and remnant wood are analyzed by neutron activation analysis (NAA) and inductively coupled plasma optical emission spectroscopy (ICP Scan) for elements with potential environmental information. Radial heartwood ring series from 300 to 700 years in length are analyzed in 20 year increments for 37 different elements. Evidence for minimal radial translocation of elements in the heartwood is presented. The radial concentration of elements in the bole is found to be coincident with early smelting activities. 7 references, 4 figures

  8. [Endarterectomy of the coronary arteries].

    Science.gov (United States)

    Fischer, V; Simkovic, I; Holoman, M; Verchvodko, P; Janotík, P; Galbánek, J; Hulman, M; Kostelnicák, J; Jurco, R; Slezák, J

    1992-02-01

    The authors analyze 50 patients with endarterectomy of the coronary arteries during the periods of 1972-1974 and 1988-1990. The results of endarterectomy of the right and left coronary artery provide evidence of its justification in indicated cases whereby contrary to some departments the results of endarterectomy of the left coronary artery are comparable with endarterectomy of the right coronary artery.

  9. Observational hints of radial migration in disc galaxies from CALIFA

    NARCIS (Netherlands)

    Ruiz-Lara, T.; Pérez, I.; Florido, E.; Sánchez-Blázquez, P.; Méndez-Abreu, J.; Sánchez-Menguiano, L.; Sánchez, S. F.; Lyubenova, M.; Falcón-Barroso, J.; van de Ven, G.; Marino, R. A.; de Lorenzo-Cáceres, A.; Catalán-Torrecilla, C.; Costantin, L.; Bland-Hawthorn, J.; Galbany, L.; García-Benito, R.; Husemann, B.; Kehrig, C.; Márquez, I.; Mast, D.; Walcher, C. J.; Zibetti, S.; Ziegler, B.

    2017-01-01

    Context. According to numerical simulations, stars are not always kept at their birth galactocentric distances but they have a tendency to migrate. The importance of this radial migration in shaping galactic light distributions is still unclear. However, if radial migration is indeed important,

  10. Radial supports of face motors with slack compensation

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsova, I I; Gelman, A B; Krekina, T V

    1982-01-01

    The design of a radial support of a face motor with slack compensation is described, and gives the results of field tests which confirm the performance capacity of the experimental support both from the viewpoint of durability, and in relation to preventing radial slack of the face motor shaft.

  11. Radial Color Gradient in a Globular Cluster 1. M68

    Directory of Open Access Journals (Sweden)

    Sukyoung Yi

    1990-12-01

    Full Text Available Stars in M68 from the observed color-magnitude diagrams with CCD were integrated to find any radial gradient. The result shows that M68 has a slightly bluer core. The main cause of these calculated radial color variations seems to come from the random distribution of giants.

  12. Modelling and analysis of radial thermal stresses and temperature ...

    African Journals Online (AJOL)

    A theoretical investigation has been undertaken to study operating temperatures, heat fluxes and radial thermal stresses in the valves of a modern diesel engine with and without air-cavity. Temperatures, heat fluxes and radial thermal stresses were measured theoretically for both cases under all four thermal loading ...

  13. Radiographic study of distal radial physeal closure in thoroughbred horses

    International Nuclear Information System (INIS)

    Vulcano, L.C.; Mamprim, M.J.; Muniz, L.M.R.; Moreira, A.F.; Luna, S.P.L.

    1997-01-01

    Monthly radiography was performed to study distal radial physeal closure in ten male and ten female Throughbred horses. The height, thoracic circumference and metacarpus circumference were also measured, Distal radial physeal closure time was sooner in females than males, and took 701 +/- 37 and 748 +/- 55 days respectively

  14. The transverse force experienced by the radial head during axial loading of the forearm: A cadaveric study.

    Science.gov (United States)

    Orbay, Jorge L; Mijares, Michael R; Berriz, Cecilia G

    2016-01-01

    When designing a radial head replacement, the magnitude and direction of forces applied across the proximal radio-ulnar joint (PRUJ) and the radiocapitellar joint must be included. These designs often focus on axial loads transmitted to the radial head by the capitellum; however, the radial head also bears a significant transverse force at the PRUJ. Load transmission by the central band of the interosseous ligament induces a force component in a lateral direction perpendicular to the axis of the limb, which is borne by the articular surfaces of the proximal and distal radio-ulnar joints. The objective of this study is to establish the relationship between distally applied axial forces and proximal transverse reaction forces. Five cadaveric, human forearms with intact interosseous membranes were used to measure the magnitude of transversely-directed forces experienced by the radial head during axial loading of the forearm at the lunate fossa. A Mark-10 test stand applied a gradual and continuous axial load on the articular surface of the distal radius. A Mark-10 force gauge measured the resultant transverse force experienced by the radial head in the proximal radioulnar joint. Classical mechanics and static force analysis were applied in order to predict lateral force values that would occur when the interosseous ligament is treated as the major load transmitter between the radius and ulna. Acquired data show that the radial head bears a force in the transverse direction that averages 18% (SD 3.89%) in magnitude of the axial force applied at the wrist. This figure is in close accordance with the predicted value of 22% that was calculated by way of free-body plotting. Physiologic forearm loading results in a clinically significant transverse force component transmitted through the interosseous ligament complex. The existence of transverse forces in the human forearm may explain clinical problems seen after radial head resection and suggest that radial head implants

  15. Popliteal Arterial Aneurysms

    African Journals Online (AJOL)

    plication was acute arterial occlusion caused by thrombo- embolism. The reasons for ... Total. 43. 55. TABLE 11. CONCOMITANT DISEASE IN 38 PATIENTS .... Dacron prosthesis in 4. .... genous saphenous vein and the type of anastomosis.

  16. Coronary artery fistula

    Science.gov (United States)

    ... PA: Elsevier Saunders; 2015:chap 84. Friedman AH, Silverman NH. Congenital anomalies of the coronary arteries. In: ... provided by VeriMed Healthcare Network. Also reviewed by David Zieve, MD, MHA, Isla Ogilvie, PhD, and the ...

  17. Radial Velocities of 41 Kepler Eclipsing Binaries

    Science.gov (United States)

    Matson, Rachel A.; Gies, Douglas R.; Guo, Zhao; Williams, Stephen J.

    2017-12-01

    Eclipsing binaries are vital for directly determining stellar parameters without reliance on models or scaling relations. Spectroscopically derived parameters of detached and semi-detached binaries allow us to determine component masses that can inform theories of stellar and binary evolution. Here we present moderate resolution ground-based spectra of stars in close binary systems with and without (detected) tertiary companions observed by NASA’s Kepler mission and analyzed for eclipse timing variations. We obtain radial velocities and spectroscopic orbits for five single-lined and 35 double-lined systems, and confirm one false positive eclipsing binary. For the double-lined spectroscopic binaries, we also determine individual component masses and examine the mass ratio {M}2/{M}1 distribution, which is dominated by binaries with like-mass pairs and semi-detached classical Algol systems that have undergone mass transfer. Finally, we constrain the mass of the tertiary component for five double-lined binaries with previously detected companions.

  18. Nonlinear radial propagation of drift wave turbulence

    International Nuclear Information System (INIS)

    Prakash, M.

    1985-01-01

    We study the linear and the nonlinear radial propagation of drift wave energy in an inhomogeneous plasma. The drift mode excited in such a plasma is dispersive in nature. The drift wave energy spreads out symmetrically along the direction of inhomogeneity with a finite group velocity. To study the effect of the nonlinear coupling on the propagation of energy in a collision free plasma, we solve the Hasegawa-Mima equation as a mixed initial boundary-value problem. The solutions of the linearized equation are used to check the reliability of our numerical calculations. Additional checks are also performed on the invariants of the system. Our results reveal that a pulse gets distorted as it propagates through the medium. The peak of the pulse propagates with a finite velocity that depends on the amplitude of the initial pulse. The polarity of propagation depends on the initial parameters of the pulse. We have also studied drift wave propagation in a resistive plasma. The Hasegawa-Wakatani equations are used to investigate this problem

  19. THE NIRSPEC ULTRACOOL DWARF RADIAL VELOCITY SURVEY

    International Nuclear Information System (INIS)

    Blake, Cullen H.; Charbonneau, David; White, Russel J.

    2010-01-01

    We report the results of an infrared Doppler survey designed to detect brown dwarf and giant planetary companions to a magnitude-limited sample of ultracool dwarfs. Using the NIRSPEC spectrograph on the Keck II telescope, we obtained approximately 600 radial velocity (RV) measurements over a period of six years of a sample of 59 late-M and L dwarfs spanning spectral types M8/L0 to L6. A subsample of 46 of our targets has been observed on three or more epochs. We rely on telluric CH 4 absorption features in Earth's atmosphere as a simultaneous wavelength reference and exploit the rich set of CO absorption features found in the K-band spectra of cool stars and brown dwarfs to measure RVs and projected rotational velocities. For a bright, slowly rotating M dwarf standard we demonstrate an RV precision of 50 m s -1 and for slowly rotating L dwarfs we achieve a typical RV precision of approximately 200 m s -1 . This precision is sufficient for the detection of close-in giant planetary companions to mid-L dwarfs as well as more equal mass spectroscopic binary systems with small separations (a +0.7 -0.6 Gyr, similar to that of nearby sun-like stars. We simulate the efficiency with which we detect spectroscopic binaries and find that the rate of tight (a +8.6 -1.6 %, consistent with recent estimates in the literature of a tight binary fraction of 3%-4%.

  20. Vortex Ring Dynamics in Radially Confined Domains

    Science.gov (United States)

    Stewart, Kelley; Niebel, Casandra; Jung, Sunghwan; Vlachos, Pavlos

    2010-11-01

    Vortex ring dynamics have been studied extensively in semi-infinite quiescent volumes. However, very little is known about vortex-ring formation in wall-bounded domains where vortex wall interaction will affect both the vortex ring pinch-off and propagation velocity. This study addresses this limitation and studies vortex formation in radially confined domains to analyze the affect of vortex-ring wall interaction on the formation and propagation of the vortex ring. Vortex rings were produced using a pneumatically driven piston cylinder arrangement and were ejected into a long cylindrical tube which defined the confined downstream domain. A range of confinement domains were studied with varying confinement diameters Velocity field measurements were performed using planar Time Resolved Digital Particle Image Velocimetry (TRDPIV) and were processed using an in-house developed cross-correlation PIV algorithm. The experimental analysis was used to facilitate the development of a theoretical model to predict the variations in vortex ring circulation over time within confined domains.

  1. Aberrant hepatic artery

    International Nuclear Information System (INIS)

    Konstam, M.A.; Novelline, R.A.; Athanasoulis, C.A.

    1979-01-01

    In a patient undergoing selective hepatic arteriography for suspected liver trauma, a nonopacified area of the liver, initially thought to represent a hepatic hematoma, was later discovered to be due to the presence of an accessory right hepatic artery arising from the superior mesenteric artery. This case illustrates the need for a search for aberrant vasculature whenever a liver hematoma is suspected on the basis of a selective hepatic arteriogram. (orig.) [de

  2. The quantitative regional cerebral blood flow measurement with autoradiography method using 123I-IMP SPECT. Evaluation of arterialized venous blood sampling as a substitute for arterial blood sampling

    International Nuclear Information System (INIS)

    Ohnishi, Takashi; Yano, Takao; Nakano, Shinichi; Jinnouchi, Seishi; Nagamachi, Shigeki; Flores, L. II; Nakahara, Hiroshi; Watanabe, Katsushi.

    1996-01-01

    The purpose of this study is validation of calibrating a standard input function in autoradiography (ARG) method by one point venous blood sampling as a substitute for that by one point arterial blood sampling. Ten and 20 minutes after intravenous constant infusion of 123 I-IMP, arterialized venous blood sampling from a dorsal vein were performed on 15 patients having ischemic cerebrovascular disease. And arterial blood sampling from radial artery was performed 10 min after 123 I-IMP infusion. The mean difference rates of integrated input function between calibrated standard input function by arterial blood sampling at 10 min and that by venous blood sampling were 4.1±3% and 9.3±5.4% at 10 and 20 min after 123 I-IMP infusion, respectively. The ratio of venous blood radioactivity to arterial blood radioactivity at 10 min after 123 I-IMP infusion was 0.96±0.02. There was an excellent correlation between ARG method CBF values obtained by arterial blood sampling at 10 min and those obtained by arterialized venous blood sampling at 10 min. In conclusion, a substitution by arterialized venous blood sampling from dorsal hand vein for artery can be possible. The optimized time for arterialized venous blood sampling was 10 min after 123 I-IMP infusion. (author)

  3. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    International Nuclear Information System (INIS)

    Rigattieri, Stefano; Valsecchi, Orazio; Sciahbasi, Alessandro; Tomassini, Francesco; Limbruno, Ugo; Marchese, Alfredo; La Manna, Alessio; Mauro, Ciro; Varbella, Ferdinando; Berti, Segio; Tarantino, Fabio F.; Musumeci, Giuseppe

    2017-01-01

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  4. Current practice of transradial approach for coronary procedures: A survey by the Italian Society of Interventional Cardiology (SICI-GISE) and the Italian Radial Club

    Energy Technology Data Exchange (ETDEWEB)

    Rigattieri, Stefano, E-mail: stefanorigattieri@yahoo.it [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Valsecchi, Orazio [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy); Sciahbasi, Alessandro [Interventional Cardiology Unit, Sandro Pertini Hospital, Roma (Italy); Tomassini, Francesco [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Limbruno, Ugo [Cardiology Unit, Azienda USL Toscana Sudest, Grosseto (Italy); Marchese, Alfredo [Interventional Cardiology Unit, Anthea Hospital, GVM Care & Research, Bari (Italy); La Manna, Alessio [Cardiovascular Department, Ferrarotto Hospital, University of Catania (Italy); Mauro, Ciro [Cardiovascular Department, Cardarelli Hospital, Napoli (Italy); Varbella, Ferdinando [Cardiology Department, Ospedale degli Infermi, Rivoli (Italy); Berti, Segio [Department of Cardiology, Fondazione Toscana “Gabriele Monasterio”, Ospedale del Cuore, Massa (Italy); Tarantino, Fabio F. [Cardiology Unit, Ospedale G.B. Morgagni-L. Pierantoni, Forlì (Italy); Musumeci, Giuseppe [Cardiovascular Department, Papa Giovanni XXIII Hospital, Bergamo (Italy)

    2017-04-15

    Background: Transradial approach (TRA) for percutaneous coronary procedures is associated with improved patient outcome and is being increasingly adopted worldwide. We surveyed Italian interventional cardiologists in order to take a snapshot of the current practice of TRA. Methods: A web-based questionnaire was emailed to all members of the Italian Society of Interventional Cardiology. Results: The survey was taken by 508 respondents. Cardiogenic shock and chronic total occlusions represented the principal limitations to TRA. Right TRA was the default approach for 81% of respondents. Both diagnostic and interventional procedures were routinely performed through 6 Fr sheaths (83% and 93%, respectively); dedicated TRA curves were used in 11% of diagnostic and in about 3% of interventional procedures. Almost 70% of the operators did not assess dual hand circulation. In case of crossover, the contralateral radial artery was the preferred site (57%). Radial artery hemostasis was mostly achieved by pneumatic bracelet (64%) and patency of the radial artery during hemostasis was ensured in 60% of cases. Pre-discharge patency of the radial artery was routinely assessed by almost 60% of respondents. For diagnostic procedures, adequate heparin anticoagulation (5000 IU) was only given by 45% of operators. Most respondents believed that TRA is associated with greater radiation exposure for both the patient (82%) and the operator (98%) as compared to transfemoral approach. Conclusions: This survey provides contemporary data about the adoption of TRA in Italy and gives interesting insights about several technical and clinical issues related to the practice of this vascular approach for coronary procedures. - Highlights: • Transradial approach for coronary procedures is becoming increasingly popular. • We conducted a survey on the contemporary practice of transradial approach in Italy. • We appraised several clinical and technical issues related to transradial approach.

  5. EEG signatures accompanying auditory figure-ground segregation.

    Science.gov (United States)

    Tóth, Brigitta; Kocsis, Zsuzsanna; Háden, Gábor P; Szerafin, Ágnes; Shinn-Cunningham, Barbara G; Winkler, István

    2016-11-01

    In everyday acoustic scenes, figure-ground segregation typically requires one to group together sound elements over both time and frequency. Electroencephalogram was recorded while listeners detected repeating tonal complexes composed of a random set of pure tones within stimuli consisting of randomly varying tonal elements. The repeating pattern was perceived as a figure over the randomly changing background. It was found that detection performance improved both as the number of pure tones making up each repeated complex (figure coherence) increased, and as the number of repeated complexes (duration) increased - i.e., detection was easier when either the spectral or temporal structure of the figure was enhanced. Figure detection was accompanied by the elicitation of the object related negativity (ORN) and the P400 event-related potentials (ERPs), which have been previously shown to be evoked by the presence of two concurrent sounds. Both ERP components had generators within and outside of auditory cortex. The amplitudes of the ORN and the P400 increased with both figure coherence and figure duration. However, only the P400 amplitude correlated with detection performance. These results suggest that 1) the ORN and P400 reflect processes involved in detecting the emergence of a new auditory object in the presence of other concurrent auditory objects; 2) the ORN corresponds to the likelihood of the presence of two or more concurrent sound objects, whereas the P400 reflects the perceptual recognition of the presence of multiple auditory objects and/or preparation for reporting the detection of a target object. Copyright © 2016. Published by Elsevier Inc.

  6. Full text and figure display improves bioscience literature search.

    Science.gov (United States)

    Divoli, Anna; Wooldridge, Michael A; Hearst, Marti A

    2010-04-14

    When reading bioscience journal articles, many researchers focus attention on the figures and their captions. This observation led to the development of the BioText literature search engine, a freely available Web-based application that allows biologists to search over the contents of Open Access Journals, and see figures from the articles displayed directly in the search results. This article presents a qualitative assessment of this system in the form of a usability study with 20 biologist participants using and commenting on the system. 19 out of 20 participants expressed a desire to use a bioscience literature search engine that displays articles' figures alongside the full text search results. 15 out of 20 participants said they would use a caption search and figure display interface either frequently or sometimes, while 4 said rarely and 1 said undecided. 10 out of 20 participants said they would use a tool for searching the text of tables and their captions either frequently or sometimes, while 7 said they would use it rarely if at all, 2 said they would never use it, and 1 was undecided. This study found evidence, supporting results of an earlier study, that bioscience literature search systems such as PubMed should show figures from articles alongside search results. It also found evidence that full text and captions should be searched along with the article title, metadata, and abstract. Finally, for a subset of users and information needs, allowing for explicit search within captions for figures and tables is a useful function, but it is not entirely clear how to cleanly integrate this within a more general literature search interface. Such a facility supports Open Access publishing efforts, as it requires access to full text of documents and the lifting of restrictions in order to show figures in the search interface.

  7. EEG signatures accompanying auditory figure-ground segregation

    Science.gov (United States)

    Tóth, Brigitta; Kocsis, Zsuzsanna; Háden, Gábor P.; Szerafin, Ágnes; Shinn-Cunningham, Barbara; Winkler, István

    2017-01-01

    In everyday acoustic scenes, figure-ground segregation typically requires one to group together sound elements over both time and frequency. Electroencephalogram was recorded while listeners detected repeating tonal complexes composed of a random set of pure tones within stimuli consisting of randomly varying tonal elements. The repeating pattern was perceived as a figure over the randomly changing background. It was found that detection performance improved both as the number of pure tones making up each repeated complex (figure coherence) increased, and as the number of repeated complexes (duration) increased – i.e., detection was easier when either the spectral or temporal structure of the figure was enhanced. Figure detection was accompanied by the elicitation of the object related negativity (ORN) and the P400 event-related potentials (ERPs), which have been previously shown to be evoked by the presence of two concurrent sounds. Both ERP components had generators within and outside of auditory cortex. The amplitudes of the ORN and the P400 increased with both figure coherence and figure duration. However, only the P400 amplitude correlated with detection performance. These results suggest that 1) the ORN and P400 reflect processes involved in detecting the emergence of a new auditory object in the presence of other concurrent auditory objects; 2) the ORN corresponds to the likelihood of the presence of two or more concurrent sound objects, whereas the P400 reflects the perceptual recognition of the presence of multiple auditory objects and/or preparation for reporting the detection of a target object. PMID:27421185

  8. Full text and figure display improves bioscience literature search.

    Directory of Open Access Journals (Sweden)

    Anna Divoli

    Full Text Available When reading bioscience journal articles, many researchers focus attention on the figures and their captions. This observation led to the development of the BioText literature search engine, a freely available Web-based application that allows biologists to search over the contents of Open Access Journals, and see figures from the articles displayed directly in the search results. This article presents a qualitative assessment of this system in the form of a usability study with 20 biologist participants using and commenting on the system. 19 out of 20 participants expressed a desire to use a bioscience literature search engine that displays articles' figures alongside the full text search results. 15 out of 20 participants said they would use a caption search and figure display interface either frequently or sometimes, while 4 said rarely and 1 said undecided. 10 out of 20 participants said they would use a tool for searching the text of tables and their captions either frequently or sometimes, while 7 said they would use it rarely if at all, 2 said they would never use it, and 1 was undecided. This study found evidence, supporting results of an earlier study, that bioscience literature search systems such as PubMed should show figures from articles alongside search results. It also found evidence that full text and captions should be searched along with the article title, metadata, and abstract. Finally, for a subset of users and information needs, allowing for explicit search within captions for figures and tables is a useful function, but it is not entirely clear how to cleanly integrate this within a more general literature search interface. Such a facility supports Open Access publishing efforts, as it requires access to full text of documents and the lifting of restrictions in order to show figures in the search interface.

  9. Free radial forearm flap versatility for the head and neck and lower extremity

    International Nuclear Information System (INIS)

    Chicarilli, Z.N.; Ariyan, S.; Cuono, C.B.

    1986-01-01

    Microsurgical techniques have developed numerous territories suitable for free tissue transfer. However, the demand for thin cutaneous resurfacing limits the choice of flaps available to the reconstructive microsurgeon. The radial forearm flap is a thin, axial, fasciocutaneous flap, offering pliable cutaneous resurfacing, with or without sensation. We have used 15 flaps to reconstruct defects in the head and neck and lower extremity resulting from burns, blunt and avulsive trauma, radiation necrosis, and tumor ablation. Two flaps (15 percent) developed venous congestion and were salvaged by reoperation. One retrograde flap (7.5 percent) developed partial necrosis from arterial insufficiency. Neural re-innervation was successful in two out of three patients in whom it was attempted. Two patients (15%) sustained minor donor site skin graft loss that healed secondarily. In our series of predominantly older patients the donor sites have been relatively inconspicuous at one year follow-up. A functional restoration was achieved in all patients

  10. ARTERIAL REVASCULARIZATION WITH THE RIGHT GASTROEPIPLOIC ARTERY AND INTERNAL MAMMARY ARTERIES IN 300 PATIENTS

    NARCIS (Netherlands)

    GRANDJEAN, JG; BOONSTRA, PW; DENHEYER, P; EBELS, T; KIRKLIN, JW

    From September 1989 to September 1992, the right gastroepiploic artery in combination with one or both internal mammary arteries was used as a graft in 300 patients who underwent coronary artery bypass grafting. The gastroepiploic artery was the primary choice in preference to the saphenous vein.

  11. Accelerated radial Fourier-velocity encoding using compressed sensing

    International Nuclear Information System (INIS)

    Hilbert, Fabian; Han, Dietbert

    2014-01-01

    Purpose:Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. Materials and Methods:We imaged the femoral artery of healthy volunteers with ECG - triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Results:Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6 - fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Conclusion: Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity

  12. Accelerated radial Fourier-velocity encoding using compressed sensing

    Energy Technology Data Exchange (ETDEWEB)

    Hilbert, Fabian; Han, Dietbert [Wuerzburg Univ. (Germany). Inst. of Radiology; Wech, Tobias; Koestler, Herbert [Wuerzburg Univ. (Germany). Inst. of Radiology; Wuerzburg Univ. (Germany). Comprehensive Heart Failure Center (CHFC)

    2014-10-01

    Purpose:Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. Materials and Methods:We imaged the femoral artery of healthy volunteers with ECG - triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Results:Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6 - fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Conclusion: Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity

  13. Accelerated radial Fourier-velocity encoding using compressed sensing.

    Science.gov (United States)

    Hilbert, Fabian; Wech, Tobias; Hahn, Dietbert; Köstler, Herbert

    2014-09-01

    Phase Contrast Magnetic Resonance Imaging (MRI) is a tool for non-invasive determination of flow velocities inside blood vessels. Because Phase Contrast MRI only measures a single mean velocity per voxel, it is only applicable to vessels significantly larger than the voxel size. In contrast, Fourier Velocity Encoding measures the entire velocity distribution inside a voxel, but requires a much longer acquisition time. For accurate diagnosis of stenosis in vessels on the scale of spatial resolution, it is important to know the velocity distribution of a voxel. Our aim was to determine velocity distributions with accelerated Fourier Velocity Encoding in an acquisition time required for a conventional Phase Contrast image. We imaged the femoral artery of healthy volunteers with ECG-triggered, radial CINE acquisition. Data acquisition was accelerated by undersampling, while missing data were reconstructed by Compressed Sensing. Velocity spectra of the vessel were evaluated by high resolution Phase Contrast images and compared to spectra from fully sampled and undersampled Fourier Velocity Encoding. By means of undersampling, it was possible to reduce the scan time for Fourier Velocity Encoding to the duration required for a conventional Phase Contrast image. Acquisition time for a fully sampled data set with 12 different Velocity Encodings was 40 min. By applying a 12.6-fold retrospective undersampling, a data set was generated equal to 3:10 min acquisition time, which is similar to a conventional Phase Contrast measurement. Velocity spectra from fully sampled and undersampled Fourier Velocity Encoded images are in good agreement and show the same maximum velocities as compared to velocity maps from Phase Contrast measurements. Compressed Sensing proved to reliably reconstruct Fourier Velocity Encoded data. Our results indicate that Fourier Velocity Encoding allows an accurate determination of the velocity distribution in vessels in the order of the voxel size. Thus

  14. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    Energy Technology Data Exchange (ETDEWEB)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe [Dept. of Medical Physics, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Fatouraee, Nasser [Dept. of Medical Engineering, Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Saben, Hazhir [Dept. Radiology, Imaging Center of Imam Khomaini Hospital, Tehran Medical Sciences University, Tehran (Iran, Islamic Republic of)

    2017-04-15

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes.

  15. Assessing the blood pressure waveform of the carotid artery using an ultrasound image processing method

    International Nuclear Information System (INIS)

    Soleimani, Effat; Mokhtari-Dizaji, Manijhe; Fatouraee, Nasser; Saben, Hazhir

    2017-01-01

    The aim of this study was to introduce and implement a noninvasive method to derive the carotid artery pressure waveform directly by processing diagnostic sonograms of the carotid artery. Ultrasound image sequences of 20 healthy male subjects (age, 36±9 years) were recorded during three cardiac cycles. The internal diameter and blood velocity waveforms were extracted from consecutive sonograms over the cardiac cycles by using custom analysis programs written in MATLAB. Finally, the application of a mathematical equation resulted in time changes of the arterial pressure. The resulting pressures were calibrated using the mean and the diastolic pressure of the radial artery. A good correlation was found between the mean carotid blood pressure obtained from the ultrasound image processing and the mean radial blood pressure obtained using a standard digital sphygmomanometer (R=0.91). The mean absolute difference between the carotid calibrated pulse pressures and those measured clinically was -1.333±6.548 mm Hg. The results of this study suggest that consecutive sonograms of the carotid artery can be used for estimating a blood pressure waveform. We believe that our results promote a noninvasive technique for clinical applications that overcomes the reproducibility problems of common carotid artery tonometry with technical and anatomical causes

  16. Learning to rank figures within a biomedical article.

    Directory of Open Access Journals (Sweden)

    Feifan Liu

    Full Text Available Hundreds of millions of figures are available in biomedical literature, representing important biomedical experimental evidence. This ever-increasing sheer volume has made it difficult for scientists to effectively and accurately access figures of their interest, the process of which is crucial for validating research facts and for formulating or testing novel research hypotheses. Current figure search applications can't fully meet this challenge as the "bag of figures" assumption doesn't take into account the relationship among figures. In our previous study, hundreds of biomedical researchers have annotated articles in which they serve as corresponding authors. They ranked each figure in their paper based on a figure's importance at their discretion, referred to as "figure ranking". Using this collection of annotated data, we investigated computational approaches to automatically rank figures. We exploited and extended the state-of-the-art listwise learning-to-rank algorithms and developed a new supervised-learning model BioFigRank. The cross-validation results show that BioFigRank yielded the best performance compared with other state-of-the-art computational models, and the greedy feature selection can further boost the ranking performance significantly. Furthermore, we carry out the evaluation by comparing BioFigRank with three-level competitive domain-specific human experts: (1 First Author, (2 Non-Author-In-Domain-Expert who is not the author nor co-author of an article but who works in the same field of the corresponding author of the article, and (3 Non-Author-Out-Domain-Expert who is not the author nor co-author of an article and who may or may not work in the same field of the corresponding author of an article. Our results show that BioFigRank outperforms Non-Author-Out-Domain-Expert and performs as well as Non-Author-In-Domain-Expert. Although BioFigRank underperforms First Author, since most biomedical researchers are either in- or

  17. Learning to rank figures within a biomedical article.

    Science.gov (United States)

    Liu, Feifan; Yu, Hong

    2014-01-01

    Hundreds of millions of figures are available in biomedical literature, representing important biomedical experimental evidence. This ever-increasing sheer volume has made it difficult for scientists to effectively and accurately access figures of their interest, the process of which is crucial for validating research facts and for formulating or testing novel research hypotheses. Current figure search applications can't fully meet this challenge as the "bag of figures" assumption doesn't take into account the relationship among figures. In our previous study, hundreds of biomedical researchers have annotated articles in which they serve as corresponding authors. They ranked each figure in their paper based on a figure's importance at their discretion, referred to as "figure ranking". Using this collection of annotated data, we investigated computational approaches to automatically rank figures. We exploited and extended the state-of-the-art listwise learning-to-rank algorithms and developed a new supervised-learning model BioFigRank. The cross-validation results show that BioFigRank yielded the best performance compared with other state-of-the-art computational models, and the greedy feature selection can further boost the ranking performance significantly. Furthermore, we carry out the evaluation by comparing BioFigRank with three-level competitive domain-specific human experts: (1) First Author, (2) Non-Author-In-Domain-Expert who is not the author nor co-author of an article but who works in the same field of the corresponding author of the article, and (3) Non-Author-Out-Domain-Expert who is not the author nor co-author of an article and who may or may not work in the same field of the corresponding author of an article. Our results show that BioFigRank outperforms Non-Author-Out-Domain-Expert and performs as well as Non-Author-In-Domain-Expert. Although BioFigRank underperforms First Author, since most biomedical researchers are either in- or out

  18. Arterial stiffness in 10-year-old children: current and early determinants.

    Science.gov (United States)

    Schack-Nielsen, Lene; Mølgaard, Christian; Larsen, Dorthe; Martyn, Christopher; Michaelsen, Kim Fleischer

    2005-12-01

    It has been suggested that CVD has its origins in early life. An impairment of fetal growth and early postnatal nutrition may have programming effects on cardiovascular physiology. In addition, traditional risk factors for CVD may initiate the atherosclerotic process during childhood. We explored the effect of fat intake, physical activity and lipid profile in childhood, and birth weight, growth during infancy and breast-feeding on arterial stiffness in a cohort study of ninety-three 10-year-old children followed during infancy and re-examined at the age of 10 years. Arterial stiffness in two arterial segments (aorto-radial and aorto-femoral) was measured as pulse wave velocity. Arterial stiffness was inversely associated with physical activity (a regression coefficient in cm/s (95 % CI) of -6.8 (-11.2, -2.4) and -3.9 (-6.9, -0.8) per h of high physical activity/d in the aorto-radial and aorto-femoral segments, respectively). Arterial stiffness was also positively associated with dietary fat energy percentage (3.1 (95 % CI 0.9, 5.2) and 1.8 (95 % CI 0.2, 3.2) per fat energy percentage in the aorto-radial and aorto-femoral segments, respectively) but was not related to body composition, insulin resistance or lipid profile. Arterial stiffness was also positively associated with duration of breast-feeding for the aorto-femoral segment only (2.1 (95 % CI 0.4, 3.7) per month) but was not associated with growth in early life. In conclusion, patterns of physical activity and diet, and history of breast-feeding in infancy, have an influence on the stiffness of the large arteries in children. The long-term effects of this are unknown.

  19. Inhibitory competition in figure-ground perception: context and convexity.

    Science.gov (United States)

    Peterson, Mary A; Salvagio, Elizabeth

    2008-12-15

    Convexity has long been considered a potent cue as to which of two regions on opposite sides of an edge is the shaped figure. Experiment 1 shows that for a single edge, there is only a weak bias toward seeing the figure on the convex side. Experiments 1-3 show that the bias toward seeing the convex side as figure increases as the number of edges delimiting alternating convex and concave regions increases, provided that the concave regions are homogeneous in color. The results of Experiments 2 and 3 rule out a probability summation explanation for these context effects. Taken together, the results of Experiments 1-3 show that the homogeneity versus heterogeneity of the convex regions is irrelevant. Experiment 4 shows that homogeneity of alternating regions is not sufficient for context effects; a cue that favors the perception of the intervening regions as figures is necessary. Thus homogeneity alone does not alone operate as a background cue. We interpret our results within a model of figure-ground perception in which shape properties on opposite sides of an edge compete for representation and the competitive strength of weak competitors is further reduced when they are homogeneous.

  20. Reduced cost and improved figure of sapphire optical components

    Science.gov (United States)

    Walters, Mark; Bartlett, Kevin; Brophy, Matthew R.; DeGroote Nelson, Jessica; Medicus, Kate

    2015-10-01

    Sapphire presents many challenges to optical manufacturers due to its high hardness and anisotropic properties. Long lead times and high prices are the typical result of such challenges. The cost of even a simple 'grind and shine' process can be prohibitive. The high precision surfaces required by optical sensor applications further exacerbate the challenge of processing sapphire thereby increasing cost further. Optimax has demonstrated a production process for such windows that delivers over 50% time reduction as compared to traditional manufacturing processes for sapphire, while producing windows with less than 1/5 wave rms figure error. Optimax's sapphire production process achieves significant improvement in cost by implementation of a controlled grinding process to present the best possible surface to the polishing equipment. Following the grinding process is a polishing process taking advantage of chemical interactions between slurry and substrate to deliver excellent removal rates and surface finish. Through experiments, the mechanics of the polishing process were also optimized to produce excellent optical figure. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. In addition to reducing the cost of producing large sapphire sensor windows, the grinding and polishing technology Optimax has developed aids in producing spherical sapphire components to better figure quality. Through specially developed polishing slurries, the peak-to-valley figure error of spherical sapphire parts is reduced by over 80%.