WorldWideScience

Sample records for radiacion gamma para

  1. Characteristics of liver tissue for attenuate the gamma radiation; Caracteristicas del tejido hepatico para atenuar la radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Arcos P, A.; Rodriguez N, S.; Pinedo S, A.; Amador V, P.; Chacon R, A.; Vega C, H.R. [Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2005-07-01

    It was determined the lineal attenuation coefficient of hepatic tissue before gamma radiation of a source of {sup 137} Cs. When exposing organic material before X or gamma radiation fields, part of the energy of the photons is absorbed by the material, while another part crosses it without producing any effect. The quantity of energy that is absorbed is a measure of the dose that receives the material. The three main mechanisms by means of which the gamma rays interacting with the matter are: The Photoelectric Effect, the Compton dispersion and the Even production; the sum of these three processes is translated in the attenuation coefficient of the radiation. In this work we have used hepatic tissue of bovine, as substitute of the human hepatic tissue, and we have measured the lineal attenuation coefficient for photons of 0.662 MeV. Through a series of calculations we have determined the lineal attenuation coefficient for photons from 10{sup -3} to 10{sup -5} MeV and the measured coefficient was compared with the one calculated. (Author)

  2. Monitoring system for gamma radiation of porch type for vehicles; Sistema de monitoreo de radiacion gamma tipo portal para vehiculos

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M.; Molina, G.; Gutierrez O, E.; Ramirez J, F.J.; Garcia H, J.M.; Aguilar B, M.A.; Vilchis P, A.E.; Cruz E, P.; Torres B, M.A. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    A monitoring system of gamma radiation for vehicles of the porch type developed in the ININ is presented. This system carries out the radiological monitoring of the vehicles in continuous form, detecting the bottom radiological environment and the presence of nuclear material transported in vehicles. The vehicles are monitored while they pass to low speed through the porch. The detectors are plastic scintillators of great volume that allow high sensibility detection. The arrangement of detecting is interconnected in net, and the data are concentrated on a personal computer whose interface man-machine can be accessed from any personal computer connected to Internet. The system monitoring in real time with options of sampling times from 50 ms configurable up to 500 ms. (Author)

  3. Research program to study the gamma radiation effects in Spanish bentonites; Programa de investigacion para estudiar los efectos de la radiacion gamma en bentonitas calcicas espanolas

    Energy Technology Data Exchange (ETDEWEB)

    Dies, J; Tarrasa, F [Universidad Politecnica de Catalunya (Spain); Cuevas de las, C; Miralles, L; Pueyo, J J [Universidad de Barcelona (Spain)

    2000-07-01

    The engineering barrier of a radioactive waste underground disposal facility, placed in a granitic host rock, will consist of a backfill of compacted bentonite blocks. At first, this material will be subjected to a gamma radiation field, from the waste canister, and heat from the spent fuel inside the canister. Moreover, any groundwater that reaches the repository will saturate the bentonite. For these reasons the performance of the engineered barrier must be carefully assessed in laboratory experiments. (Author)

  4. Thermoluminescent relative efficiencies of TLD-100 for nitrogen ions respect of gamma radiation; Eficiencias termoluminiscentes relativas de TLD-100 para iones de nitrogeno respecto de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Concha S, K. [UNAM, Facultad de Ciencias, 04510 Mexico D.F. (Mexico); Avila, O. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gamboa de Buen, I. [ICN-UNAM, 04510 Mexico D.F. (Mexico); Rodriguez V, M.; Buenfil, A.E.; Ruiz T, C.; Brandan, M.E. [IFUNAM, 04510 Mexico D.F. (Mexico)

    2004-07-01

    The purpose of this work is to measure the thermoluminescent relative efficiency of those TLD-100 dosemeters irradiated with nitrogen ions with respect to the gamma radiation of {sup 60} Co, in function of the linear energy transfer (LET). Two energy of such nitrogen ions were selected that has the same value from LET when impacting in the dosemeters but with E{sub 1} energy (4.8 MeV) and E{sub 2} (9.95 MeV) smaller and greater respectively that the energy of the Bragg peak. (Author)

  5. Preliminary study of the quarantine treatment by gamma rays for codling moth (Cydia pomonella) in apples and pears; Estudio preliminar para el tratamiento cuarentenario por radiacion gamma para carpocapsa (Cydia pomonella) en manzanas y peras

    Energy Technology Data Exchange (ETDEWEB)

    Yusef, Maria V; Kaupert, Norma L [Comision Nacional de Energia Atomica, Ezeiza (Argentina). Dept. de Aplicaciones Tecnologicas y Agropecuarias; Quintana, G M [Instituto Nacional de Tecnologia Agropecuaria (INTA), Castelar (Argentina). Inst. de Microbiologia y Zoologia Agricola

    1999-07-01

    After irradiation, important variations have been observed in the behaviour and metabolism of the moth larvae that are clearly attributable to the effects of gamma rays. The variation includes the loss of the characteristic pink colour, partial or total loss of appetite, loss of turgidity, etc. (author)

  6. EPR response of sucrose and microcrystalline cellulose to measure high doses of gamma radiation; Respuesta EPR de sacarosa y celulosa micro cristalina para medir altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Torijano, E.; Cruz, L.; Gutierrez, G.; Azorin, J.; Aguirre, F. [Universidad Autonoma Metropolitana, Unidad Iztapalapa, Av. San Rafael Atlixco 186, Col. Vicentina, 09340 Mexico D. F. (Mexico); Cruz Z, E., E-mail: eftc@xanum.uam.mx [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico)

    2015-10-15

    Solid dosimeters of sucrose and microcrystalline cellulose (Avicel Ph-102) were prepared, following the same process, in order to compare their EPR response against that of the l-alanine dosimeters considered as reference. All lots of dosimeters were irradiated with gamma radiation in Gamma beam irradiator with 8 kGy/h of the Nuclear Sciences Institute of UNAM. Doses ranged from 1 to 10 kGy respectively. We found that both the response of sucrose as microcrystalline cellulose were linear; however, the response intensity was, on average, twenty times more for sucrose. Comparing this against the EPR response of l-alanine in the range of doses, it was found that the response to sucrose is a third part; and microcrystalline cellulose is a sixtieth, approximately. The results agree with those found in the literature for sucrose, leaving open the possibility of investigating other dosage ranges for cellulose. (Author)

  7. Calibration curve to establish the exposure dose at Co{sup 60} gamma radiation; Curva de calibracion para establecer dosis de exposicion a radiacion gamma de Co{sup 60}

    Energy Technology Data Exchange (ETDEWEB)

    Guerrero C, C; Brena V, M [Departamento de Biologia, Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, Mexico D.F. (Mexico)

    2000-07-01

    The biological dosimetry is an adequate method for the dose determination in cases of overexposure to ionizing radiation or doubt of the dose obtained by physical methods. It is based in the aberrations analysis produced in the chromosomes. The behavior of leisure in chromosomes is of dose-response type and it has been generated curves in distinct laboratories. Next is presented the curve for gamma radiation produced in the National Institute of Nuclear Research (ININ) laboratory. (Author)

  8. Decay profiles of {beta} and {gamma} for a radionuclide inventory in equilibrium cycle of a BWR type reactor; Perfiles de decaimiento de radiacion {beta} y {gamma} para un inventario de radionuclidos en ciclo de equilibrio de un reactor tipo BWR

    Energy Technology Data Exchange (ETDEWEB)

    Salaices, M.; Sandoval, S.; Ovando, R. [Instituto de Investigaciones Electricas. Gerencia de Energia Nuclear, Av. Reforma 113 Col. Palmira. 62490 Cuernavaca, Morelos (Mexico)]. e-mail: sal@iie.org.mx

    2007-07-01

    Presently work the {beta} and {gamma} radiation decay profiles for a radionuclides inventory in equilibrium cycle of a BWR type reactor is presented. The profiles are presented in terms of decay in the activity of the total inventory as well as of the chemical groups that conform the inventory. In the obtaining of the radionuclides inventory in equilibrium cycle the ORIGEN2 code, version 1 was used, which simulates fuel burnup cycles and it calculates the evolution of the isotopic composition as a result of the burnt one, irradiation and decay of the nuclear fuel. It can be observed starting from the results that the decrease in the activity for the initial inventory and the different chemical groups that conform it is approximately proportional to the base 10 logarithm of the time for the first 24 hours of having concluded the burnt one. It can also be observed that the chemical groups that contribute in more proportion to the total activity of the inventory are the lanthanides-actinides and the transition metals, with 39% and 28%, respectively. The groups of alkaline earth metals, halogens, metalloids, noble gases and alkaline metals, contribute with percentages that go from the 8 to 5%. The groups that less they contribute to the total activity of the inventory they are the non metals and semi-metals with smaller proportions that 1%. The chemical groups that more contribute to the energy of {beta} and {gamma} radiation its are the transition metals and the lanthanides-actinides with a change in the order of importance at the end of the 24 hours period. The case of the halogens is of relevance for the case of the {gamma} radiation energy due that occupying the very near third site to the dimensions of the two previous groups. Additionally, the decay in the activity for the total inventory and the groups that conform it can be simulated by means of order 6 polynomials or smaller than describe its behavior appropriately. The results presented in this work, coupled

  9. Interval for the expression of the adaptive response induced by gamma radiation in leucocytes of mouse In vivo; Intervalo para la expresion de la respuesta adaptativa inducida por radiacion gamma en leucocitos de raton In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M T; Morales R, P [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    The interval between the adaptive gamma radiation dose (0.01 Gy) and challenge (1.0 Gy) capable to induce the maximum expression of the adaptive response in lymphocytes of mouse In vivo. The animals were exposed to the mentioned doses with different intervals among both (1, 1.5, 5 or 18 hr). By means of the unicellular electrophoresis in gel technique, four damage parameters were analysed. The results showed that from the 1 hr interval an adaptive response was produced since in the pretreated organisms with 0.01 Gy the cells present lesser damage than in those not adapted. The maximum response was induced with the intervals between 2.5 and 5 hr and even though it persisted until 18 hr, the effect was reducing. (Author)

  10. The ferrous ammonium sulfate solid system, as dosemeter for processes at low temperatures and high doses of gamma radiation; El sistema sulfato ferroso amoniacal solido, como dosimetro para procesos a bajas temperaturas y altas dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Juarez C, J.M.; Ramos B, S.; Negron M, A. [ICN-UNAM, 04510 Mexico D.F. (Mexico)

    2005-07-01

    This paper presents the results obtained from a study of the radiation induced oxidation of crystalline ferrous ammonium sulfate with gamma rays at 295 K, 263 K and 77 K and dose from 0 to 300 kGy. The radiation induced decomposition of ferrous ammonium sulfate has been studied by the dissolution of the irradiated salt in 0,8 N sulfuric acid. The main product is Fe{sup 3+} and molar concentration of ferric ion was determined spectrophotometrically in the UV region at 304 nm. The optical density values showed a linear dependence with dose, indicating that the data obtained might be used to create a calibrating curve. Color in irradiated salt changes from blue to green, yellow and orange according to the absorbed dose. The accuracy and the reproducibility of the system were tested. In addition, some other characteristics make possible the use of this system as a dosimeter, similar to Fricke chemical dosemeter, at low temperatures and high dose. (Author)

  11. Residual water treatment for gamma radiation. Tratamiento de aguas residuales por radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mendez, L [Universidad Nacional Mayor de San Marcos. Facultad de Quimica (Peru)

    1990-07-01

    The treatment of residual water by means of gamma radiation for its use in agricultural irrigation is evaluated. Measurements of physical, chemical, biological and microbiological contamination indicators were performed. For that, samples from the treatment center of residual water of San Juan de Miraflores were irradiated up to a 52.5 kGy dose. The study concludes that gamma radiation is effective to remove parasites and bacteria, but not for removal of the organic and inorganic matter. (author). 15 refs., 3 tabs., 4 figs.

  12. Thermoluminescence of sulfated zircon exposed to gamma radiation; Termoluminiscencia de circonia sulfatada expuesta a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Rubio, E.; Castano, V.M. [Centro de Fisica Aplicada y Tecnologia Avanzada, UNAM, A.P. 1-1010, 76000 Queretaro (Mexico); Mendoza A, E.; Gonzalez, P.R. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2003-07-01

    In this work, the thermoluminescent (Tl) signal induced by gamma radiation in zirconia and sulfated zirconia samples embedded in Ptfe pellets is reported and discussed. In this case, samples were obtained through sol-gel method using zirconium n-propoxide and H{sub 2}SO{sub 4} as precursors, and later were subjected to thermal treatment at 600 C to obtain, the tetragonal phase accordingly to X-ray diffraction analysis. Experimental results show that the thermoluminescent glow peak depends on both, the crystalline structure and sulfate concentration. Two maximum peaks were observed located at 147 C and 274 C arising from the electronic transitions. Tl response as a function of the absorbed dose shows a linear increase for a wide of range exposure as well as good stability in time. The high sensitivity, dose linearity and signal stability of this material open the potential possibility to be used for the dosimetry applications. (Author)

  13. Mobile robot prototype detector of gamma radiation; Prototipo de robot movil detector de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez C, R.M. [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Duran V, M. D.; Jardon M, C. I., E-mail: raulmario.vazquez@inin.gob.mx [Tecnologico de Estudios Superiores de Villa Guerrero, Carretera Federal Toluca-Ixtapan de la Sal Km. 64.5, La Finca Villa Guerrero, Estado de Mexico (Mexico)

    2014-10-15

    In this paper the technological development of a mobile robot prototype detector of gamma radiation is shown. This prototype has been developed for the purpose of algorithms implementation for the applications of terrestrial radiation monitoring of exposed sources, search for missing radioactive sources, identification and delineation of radioactive contamination areas and distribution maps generating of radioactive exposure. Mobile robot detector of radiation is an experimental technology development platform to operate in laboratory environment or flat floor facilities. The prototype integrates a driving section of differential configuration robot on wheels, a support mechanism and rotation of shielded detector, actuator controller cards, acquisition and processing of sensor data, detection algorithms programming and control actuators, data recording (Data Logger) and data transmission in wireless way. The robot in this first phase is remotely operated in wireless way with a range of approximately 150 m line of sight and can extend that range to 300 m or more with the use of signal repeaters. The gamma radiation detection is performed using a Geiger detector shielded. Scan detection is performed at various time sampling periods and diverse positions of discrete or continuous angular orientation on the horizon. The captured data are geographical coordinates of robot GPS (latitude and longitude), orientation angle of shield, counting by sampling time, date, hours, minutes and seconds. The data is saved in a file in the Micro Sd memory on the robot. They are also sent in wireless way by an X Bee card to a remote station that receives for their online monitoring on a laptop through an acquisition program by serial port on Mat Lab. Additionally a voice synthesizing card with a horn, both in the robot, periodically pronounced in Spanish, data length, latitude, orientation angle of shield and detected accounts. (Author)

  14. Riesgo para la salud por radiaciones no ionizantes de las redes de telecomunicaciones en el Perú

    Directory of Open Access Journals (Sweden)

    Víctor M. Cruz

    2009-01-01

    Full Text Available Se revisa los diferentes estudios sobre los posibles efectos de las redes de telecomunicaciones sobre la salud, en dichos estudios refieren que los posibles efectos en la salud se deben al efecto térmico de las radiaciones no ionizantes que producen incrementos de temperatura corporal mayores a 1 ºC. Por otro lado, se revisó los estudios de evaluación de la exposición a las radiaciones no ionizantes de las redes de telecomunicaciones realizadas en el Perú entre el 2000 al 2006 que incluyen la medición de más de 500 lugares. Los niveles promedio más altos de exposición en el Perú son producidos por los servicios de radio FM y están en el orden de 29% de los límites recomendados, mientas los producidos por de las estaciones bases de telefonía móvil son de 1,5% a nivel poblacional. Los niveles más altos de exposición se dan por los teléfonos móviles aunque siguen estando dentro de los límites permisivos. La evaluación de riesgo de las radiaciones no ionizantes de las redes de telecomunicaciones en el Perú demuestra que el riesgo para la salud de las estaciones fijas es no significativo, pero en el caso de las estaciones portátiles (celulares el riesgo es mayor y su importancia dependerá de los resultados de las investigaciones internacionales que están en curso.

  15. Development of a nano structured system based on zirconia and Co nanoparticles for thermoluminescent applications: sensor of gamma and UV radiation; Desarrollo de un sistema nanoestructurado a base de zirconia y nanoparticulas de Co para aplicaciones termoluminiscentes: sensor de radiacion gamma y UV

    Energy Technology Data Exchange (ETDEWEB)

    Villa S, G.

    2014-07-01

    Powders of zirconium IV oxide as well as systems composed of zirconia nano crystals and cobalt nanoparticles (ZrO{sub 2}:NPCo) with dimensions of nanometers were synthesized by the sol-gel method. Zirconia and ZrO{sub 2}:NPCo systems have crystalline structure tetragonal or monoclinic is the heat treatment was to 500 and 1000 degrees Celsius respectively. The characterization of the synthesized materials consisted of a morphological and structural analysis, the information obtained was correlated to its thermoluminescent response induced by gamma and ultraviolet radiation. Thermoluminescent behavior was analyzed on different concentrations of cobalt nanoparticles incorporated during the synthesis process of the zirconium oxide. The monoclinic structure has the highest sensitivity thermoluminescent induced by ultraviolet and gamma radiation. Moreover, the thermoluminescence intensity decreased considerably in ZrO{sub 2}:NPCo systems and was induced the growth of a glow peak at 280 degrees Celsius. In most of the materials analyzed the relation of the thermoluminescence intensity depending the time of irradiation with ultraviolet light showed the saturation of the traps in the material after 60 s of irradiation. Using gamma radiation is observed a behavior linear in the applied dose range between 0.25 Gy and 450 Gy. The growth of a glow peak at 280 degrees Celsius is the most important change in the thermoluminescence characteristics of zirconia. The ZrO{sub 2}:NPCo systems can be used in the development of thermoluminescent dosimeters for detecting gamma radiation fields mainly. (Author)

  16. Resonance absorption of nuclear gamma radiation; Absorption par resonance des rayons gamma; Rezonansnaya absorbtsiya i rasseyanie yadernogo gamma-izlucheniya; Absorcion por resonancia de las radiaciones gamma en los nucleos

    Energy Technology Data Exchange (ETDEWEB)

    Hanna, S S; Perlow, G J [Argonne National Laboratory, Argonne, IL (United States)

    1962-01-15

    electromagnetiques. L'absorption par resonance dans le {sup 57}Fe a ete etudiee en detail. L'intensite de l'absorption, la configuration des raies spectrales et leurs deplacements ont ete observes en fonction de la temperature. La polarisation des rayonnements a ete examinee au cours d'experiences effectuees a l'aide de sources et absorbeurs magnetises. Le spectre hyperfin des rayonnements de resonance a ete analyse avec et sans polarisation. Ces etudes ont conduit a une interpretation de la structure hyperfine en fonction des proprietes des etats nucleaires et de l'interaction hyperfine dans le fer. On a egalement etudie l'effet d'un champ magnetique externe sur la structure hyperfine. L'absorption par resonance dans le {sup 57}Fe a permis d'etudier le rapport entre la chronologie de la desintegration d'un etat nucleaire et le spectre des rayonnements observes. Des observations detaillees ont ete faites sur le spectre des rayonnements de resonance filtres, en fonction du temps, sous toute une serie de conditions. (author) [Spanish] Como ha demostrado Moesbauer, la emision y absorcion sin retrocesos de las radiaciones nucleares proporciona un medio sencillo de estudiar la interaccion entre los nucleos y las radiaciones electromagneticas y, lo que tiene mas importancia aun, un instrumento extremadamente sensible para la investigacion de numerosos problemas fisicos. El nucleo del {sup 57}Fe constituye un ejemplo muy interesante, ya que en el la absorcion por resonancia constituye un detector de gran sensibilidad de los cambios de frecuencia de las radiaciones electromagneticas. Los autores han estudiado detalladamente la absorcion por resonancia en el {sup 57}Fe. Han observado la intensidad de la absorcion, asi como la configuracion y el desplazamiento de las lineas espectrales en funcion de la temperatura. Examinaron la polarizacion de las radiaciones mediante experimentos realizados con ayuda de fuentes magnetizadas y de absorbentes, y analizaron el espectro hiperfino de la

  17. Preparation of denatured protein bone sterilized with gamma radiation; Preparacion de hueso desproteinizado esterilizado con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Luna Z, D [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2005-07-01

    The bone is one of the tissues more transplanted in the entire world by that the bone necessity for transplant every day becomes bigger. In the Bank of tissues Radio sterilized of the ININ the amnion and the pig skin are routinely processed. The tissue with which will be continued is with bone. Due to that in our country it doesn't have enough bone of human origin for the necessities required in the bone transplant, an option is the bone of bovine. Of this bone one can obtain denatured protein bone, with the same characteristics of the denatured protein human bone, the one which has been proven that it has good acceptance and incorporation in the human body when is transplanted. The method for the obtaining of the denatured protein bone of bovine, with the confirmation of the final product by means of X-ray diffraction is described. The radiosterilization of this bone with gamma rays and the determination of the lead content. (Author)

  18. Preparation of denatured protein bone sterilized with gamma radiation; Preparacion de hueso desproteinizado esterilizado con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Luna Z, D. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: dlz@nuclear.inin.mx

    2005-07-01

    The bone is one of the tissues more transplanted in the entire world by that the bone necessity for transplant every day becomes bigger. In the Bank of tissues Radio sterilized of the ININ the amnion and the pig skin are routinely processed. The tissue with which will be continued is with bone. Due to that in our country it doesn't have enough bone of human origin for the necessities required in the bone transplant, an option is the bone of bovine. Of this bone one can obtain denatured protein bone, with the same characteristics of the denatured protein human bone, the one which has been proven that it has good acceptance and incorporation in the human body when is transplanted. The method for the obtaining of the denatured protein bone of bovine, with the confirmation of the final product by means of X-ray diffraction is described. The radiosterilization of this bone with gamma rays and the determination of the lead content. (Author)

  19. Design and implementation of a system for controlling emission of radiation; Diseno e implementacion de un sistema para el control de emision de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Alfaro, Luis Diego

    2012-07-01

    The Centro de Investigacion en Ciencias Atomicas, Nucleares y Moleculares of the Universidad de Costa Rica has seen the need to automate the process of changing filters, so that no person has to be exposed to the radiation emitted by the source, which can be very harmful to health. A graphical interface and a controller is implemented using the LabView software, to manipulate and detect the position of a rotating disk to a radiation source. The rotary disk is used in the Center by means of a microcontroller Arduino UNO and a stepper motor. An actuator and a stepper motor, controlled through signals sent by an Arduino UNO, have been defined and implemented in a first stage, by an integrated module of bridges H and an optical system to locate the position of the filters. The second stage has been the creation in parallel of a virtual instrument in LabView, with routines able to move the stepper motor shaft to a desired position, along with its graphical interface, adaptable to any stepper motor bipolar or unipolar, and simple to use. The program has been validated to verify proper operation, by a routine in which filters are chosen randomly and persons handling the program. The stages have been documented along with the user manual for proper use of virtual instrument and system assembly. (author) [Spanish] El Centro de Investigacion en Ciencias Atomicas, Nucleares y Moleculares de la Universidad de Costa Rica ha visto la necesidad de automatizar el proceso de cambio de filtros, de tal manera que ninguna persona tuviera que estar expuesta a la radiacion emitida por la fuente, que puede resultar muy danina para la salud. Una interfaz grafica y un controlador se ha implementado utilizando el software LabView, para manipular y detectar la posicion de un disco giratorio para una fuente de radiacion. El disco giratorio es utilizado en el Centro por medio de un microcontrolador Arduino UNO y un motor a pasos. Un actuador y un motor a pasos, controlados a traves de senales

  20. Effect of Gamma Radiation on Polyethyl Acrylate; Effet des rayons gamma sur le polyethylacrylate; Dejstvie gamma-izlucheniya na akrilat poliehtila; Efectos de las radiaciones gamma sobre el poliacrilato de etilo

    Energy Technology Data Exchange (ETDEWEB)

    Heyns, H; Desreux, V [Laboratory of Physical Chemistry, University of Liege (Belgium)

    1960-07-15

    polymere. L'influence de l'oxygene ou d'inhibiteurs est etudiee. Des irradiations ont ete egalement faites a l'etat solide. Elles montrent que dans ce cas il y a reticulation que ce soit en presence ou en absence d'oxygene. Cette reticulation est accompagnee d'une degradation plus ou moins importante suivant les cas. Enfin des essais faits en solutions concentrees dans le tetrachlorure de carbone montrent que dans ce cas il y a competition entre la degradation et la reticulation. (author) [Spanish] Los autores estudiaron los efectos ejercidos por las radiaciones emitidas por el cobalto-60 sobre muestras de poliacrilato de etilo de diferentes pesos moleculares, en estado solido y disueltas en benceno y tetracloruro de carbono; los ensayos se realizaron a la temperatura ambiente en ausencia y en presencia de aire. Los autores no observaron efecto de postirradiacion alguno. Al irradiar soluciones diluidas con dosis crecientes de rayos gamma en presencia de aire, comprobaron que la viscosidad intrinseca y la constante de sedimentacion experimentan una disminucion. Los resultados obtenidos pueden interpretarse admitiendo que se produce una degradacion de las moleculas de poliacrilato de etilo. Tanto el efecto directo como el indirecto son proporcionales a la dosis y varian segun el disolvente. Ambos son directamente proporcionales al peso molecular inicial del polimero. Los autores estudieron la influencia oxigeno y de algunos agentes inhibidores. Tambien han sometido a irradiacion muestras en estado solido. En este caso, la reticulacion se produce tanto en presencia como en ausencia de oxigeno. Esta reticulacion va acompanada de una degradacion de importancia variable. Por otra parte, los ensayos realizados con soluciones concentradas de poliacrilato de etilo en tetracloruro de carbono demuestran que el proceso de degradacion compite con el de reticulacion. (author) [Russian] Avtory izuchayut dejstvie izlucheniya kobal'ta-60 na obraztsy akrilata poliehtila s razlichnym

  1. Changes in the chromogene properties of the betalaine; Cambios en las propiedades cromogenas de las betalainas inducidos por radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez N, S.; Pinedo S, A.; Amador V, P.; Chacon R, A.; Arcos P, A.; Vega C, H.R. [Unidad Academica de Ciencias Nucleares, C. Cipres 10, Fracc. La Penuela, 98068, Zacatecas, Zac. (Mexico)

    2005-07-01

    The changes of coloration of four natural extracts were determined in function of the absorbed dose taken place by a source of rays gamma of Cs-137. The used natural extracts contain betalaine that are natural pigments of some plants as the beet root, of there their name. They are also in abundant form in the fruits (tunas) of some species of the Opuntia gender. The extracts were obtained by maceration, starting from beet root and three tuna varieties, and they were stabilized to pH 5.5 the change of coloration you determines in a spectrophotometer ultraviolet/visible by means of the absorbance from the samples to photons of 475, 535 and 600 nm of wave longitude. The absorbance was measured, to different intervals of time. The relationship settled down between the absorbed dose and the chromogene properties of the pigment, with the intention of using it as possible dosemeter. (Author)

  2. Effect of gamma radiation on growth, productivity and protein content of Chlorella Pyrenoidosa; Efecto de la radiacion gamma sobre el crecimiento, productividad y contenido proteico de Chlorella Pyrenoidosa

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C; Fernandez, J

    1983-07-01

    The effect of five doses of gamma radiation: 10, 100, 500, 1000 and 5000 Gy at a dose rate of 4.500 Gy/h on growth, productivity and protein content of Chlorella pyroneidosa has been studied. High doses of gamma radiation have been observed to inhibit cellular division of Chlorella pyrenoidosa. Culture growth stopped 48 hours after irradiation at 5.000 Gy and 72 hours after irradiation at 500 and 1000 Gy. The lowest dose (10 Gy) produced a little growth stimulation that not statistically significative. Protein and aminoacid content did not show any change for gamma radiation doses studied. (Author) 32 refs.

  3. Sterilization of Normal Human Plasma and Some of its Fractions by Means of Gamma Rays; Esterilizacion del plasma normal humano y algunas de sus fracciones por medio de radiaciones gamma

    Energy Technology Data Exchange (ETDEWEB)

    López Martínez de Alva, L.; Crespo, Y M. [Cortina Comision Nacional de Energia Nuclear (Mexico)

    1967-09-15

    radiaciones ultravioleta. El otro metodo es el uso de la ß-propiolactona que se ha desechado tambien рог las alteraciones que producía en la estructura de las protefnas plasmáticas. El objeto de este trabajo, que debe considerarse como una nota preliminar, es presentar los resultados obtenidos al esterilizar por medio de radiaciones gamma ({sup 60}Co, 1,3316 MeV) con dosis variables de 2, 2,5 у 3 Mrad un producto que, como el plasma que contiene proteínas muy lábiles, podría ser fácilmente alterado en su estructura por la radiacion. Tambien se sometieron a las mismas dosis: fibrogeno puro, gamma globulina pura у albúmina de origen humano; los resultados fueron muy satisfacforios, ya que quedo de manifiesto que no se pudieron demostrar alteraciones apreciables en cuanto a su estructura, solubilidad у características bioquímicas. Mediante pruebas simples de coagulacion se puso de manifiesto que algunas de las proteínas que intervienen en este mecanismo, como la protrombina, el factor Power- Stuart у el factor Hageman, prácticamente no se alteraban. Todas las muestras de plasma у de las diferentes proteínas fueron previamente liofilizadas, procurando que el contenido máximo de humedad fuera de 0,034%, con el objeto de evitar la ionizacion del contenido de agua que la tiansformaría en agua oxigenada que alteraría у oxidaría las proteínas. Los plasmas liofilizados previamente contaminados con diferentes cepas у virus demostraron wue con dosis tan bajas como 2 Mrad quedaban esteriles. Por último, se puso de manifiesto que este es un metodo sencillo у práctico, ya que la esterilizacion puede verificarse en el envase final. (author)

  4. Copolymerization of Ethylene Induced by Cobalt-60 Gamma Radiation; Copolymerisation de l'ethylene induite par des rayons gamma du cobalt-60; Sopolimerizatsiya ehtilena pod dejstviem gamma-izlucheniya ot istochnika ks'yali-60; Copolimerizacion del etileno inducida por las radiaciones gamma del cobalto-60

    Energy Technology Data Exchange (ETDEWEB)

    Steinberg, M.; Colombo, P. [Brookhaven National Laboratory, Long Island, NY (United States)

    1963-11-15

    }C et a des pressions initiales allant jusqu'a 680 atm. On a procede aux experiences, en milieu statique, dans des systemes a deux phases, a l'exception du systeme ethylene-oxyde de carbone. La separation des copolymeres a ete obtenue par des methodes d'extraction par solvant et de precipitation fractionnee. L'identification a ete faite au moyen de la spectroscopic aux infrarouges. La composition a ete determinee par analyse elementaire. Les auteurs donnent une evaluation partielle de certains produits de la reaction, y compris les points de fusion cristalline, les densites, les caracteristiques de solubilite et les poids moleculaires. La copolymerisation de l'ethylene a ete etablie avec chacun des monomeres suivants : styrene, methacrylate de methyle, acetate de vinyle, acrylonitrile, acetate d'allyle, isobutylene, chlorotiifluoroethylene, transbutene-2, acrylate de methyle, isoprene, propylene, chlorure de vinyle, butene-1, cis-butene-2, oxyde de carbone, pyrrolidone de vinyle, methyle- vinyle-cetone et divinyle-benzene. Les auteurs ont trouve que les donnees experimentales obtenues dans l'etude du systeme ethylene-oxyde de carbone suivaient une forme lineaire de l'equation de composition du copolymere. Pour le rapport {alpha} des constantes de vitesse specifiques de l'oxyde de carbone et de l'ethylene, ils ont determine la valeur 22,0, ce qui montre que l'oxyde de carbone en tant que monomere est active a tel point qu'il se fixe a l'extremite d'une chaftie de radicaux libres d'ethylene 22 fois plus vite que ne le fait un monomere d'ethylene. (author) [Spanish] Los autores estudiaron la copolimerizacion del etileno, inducida por las radiaciones gamma, con una serie de diversos monometos, a 20{sup o}C y presiones iniciales de hasta 680 atm. Los experimentos se llevaron a cabo estaticamente en sistemas bifasicos, salvo en el caso del etileno-oxido de carbono. La separacion de los copolimeros se llevo a cabo por extraccion mediante disolventes y por precipitacion

  5. Response of avocado genotypes to improvement through {sup 60}Co gamma radiation; Respuesta de diversos genotipos de aguacate al mejoramiento por radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, E De la; Rubi A, M; Garcia A, J M [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Ten avocado genotypes were subjected to gamma radiation from 0 to 45 Gy in 1993. Vegetative and reproductive data were analysed in a factorial design. Genotypes differed significative on height and fruit number. Radiation affected significative fruit number but not tree height. ''Hass'' showed strongest interaction between genotype and doses, for fruit number. (Author)

  6. Obtention of zinc polymethacrylate via free radicals induced by gamma radiation; Obtencion del polimetacrilato de zinc via radicales libres inducidos por radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Urena N, F.; Flores E, J. [Departamento de Fisica, Instituto Nacional de Investigaciones Nucleares, C.P. 52045 Estado de Mexico (Mexico)

    2000-07-01

    The objective of this work was to synthesise the monomer of zinc methacrylate and subsequently to carry out the polymerization reaction with the purpose to obtain the compound desired, the zinc polymethacrylate. For this it was used a gamma radiation source, {sup 60} Co, as initiator of the polymerization reaction. (Author)

  7. Response of avocado genotypes to improvement through {sup 60}Co gamma radiation; Respuesta de diversos genotipos de aguacate al mejoramiento por radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz, E. De la; Rubi A, M.; Garcia A, J.M. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1997-07-01

    Ten avocado genotypes were subjected to gamma radiation from 0 to 45 Gy in 1993. Vegetative and reproductive data were analysed in a factorial design. Genotypes differed significative on height and fruit number. Radiation affected significative fruit number but not tree height. ''Hass'' showed strongest interaction between genotype and doses, for fruit number. (Author)

  8. Quantification by Raman spectroscopy of the gamma radiation effects in water purification; Cuantificacion por espectroscopia Raman de los efectos de la radiacion gamma en la purificacion de agua

    Energy Technology Data Exchange (ETDEWEB)

    Perez C, V M; Santiago J, P; Castano, V M [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The world problem about water pollution has been confronted by traditional methods such as: chlorination, filtration, etc. In this work is presented an alternative method, which consists in to radiate different concentrations of simulated polluted water (purified water + thinner) at different gamma radiation doses. The structural changes were analysed by Raman spectroscopy. Using a 52.5 Krad dose it was possible to eliminate all the thinner chemical linkages, which appear in the Raman spectra corresponding to the 87.5/12.5 water/thinner mixture. (Author)

  9. Gamma radiation outside the PIBA in the environmental impact assesment; La radiacion gamma fuera de la PIBA en el estudio de impacto ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Mangussi, M J; Caporale, M C [Universidad Tecnologica Nacional, San Miguel de Tucuman (Argentina)

    2003-07-01

    A nuclear aspect of the Environmental Assessment for a sewage sludge irradiation plant working with 700,000 Ci of {sup 60}Co are analysed and discussed. This plant is the first one in Argentina and it is placed at a 500,000 inhabitants agricultural city without nuclear tradition. The gamma irradiation risk for the human beings and for the environment is evaluated by using the software, specifically developed in Delphi 5 language, meant for the environmental authorities and common people perusing. This PC application shows the effective dose rate over suitable plans at any point around the irradiation plant and the isorate zones on a color scheme. (author)

  10. Evaluation gives productivity and quality gives fruit in Aguacate subjected has to gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate hass sometido a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    De La Cruz Torres, Eulogio; Garcia Andrade, Juan M [Instituto Nacional de Investigaciones Nucleares. Mexico D.F. (Mexico); Ibannez Palacios, Jorge [Facultad de Ciencias Agricolas. U.A.E., Toluca (Mexico); Mijares Oviedo, Pedro [Fundacion Salvador Sanchez Col CICTAMEX, Coatepec Harina (Mexico)

    1999-07-01

    Evaluation of productivity, post harvest behavior and fruit quality was performed on four years Has avocado trees irradiated with 60 Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the La Labor Experimental Center of the Centro de Investigaciones Cientificas y Tecnologicas del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300%. In regard to post harvest performance, the respiration index (mg CO2 /kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This means that radiation has altered productivity but not the quality and post harvest behavior of fruits.

  11. Changes in the chromogen properties of the betalaine induced by gamma radiation; Cambios en las propiedades cromogenas de las betalainas inducidos por radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez N, S.; Pinedo S, A.; Amador V, P.; Chacon R, A.; Arcos P, A.; Vega C, H.R. [Unidad Academica de Ciencias Nucleares, C. Cipres 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2005-07-01

    The changes of coloration of four natural extracts in function of the absorbed dose produced by a gamma rays source of {sup 137} Cs were determined. The natural extracts used contain betalaines that are natural pigments of some plants as the beet about that their name. They are also in abundant form in the fruits (tunas) of some species of the Opuntia genus. The extracts were obtained by maceration, starting from beet and three tuna varieties, and they were stabilized to pH 5.5 The change of coloration it was determined in a visible ultraviolet spectrophotometer by means of the absorbance from the samples to photons of 475, 535 and 600 nm of wavelength. The absorbance to different intervals of time was measured. The relationship between the absorbed dose and the chromogene properties of the pigment, with the intention of using it as possible dosemeter was settled down. (Author)

  12. Changes induced by gamma radiation in microsomal membranes of storage of garlic; Cambios provocados por la radiacion gamma en membranas microsomales de hoja de reserva de ajo

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M B; Croci, C A [Universidad Nacional del Sur, Bahia Blanca (Argentina). Laboratorio de Radioisotopos; Aveldano, M I [Universidad Nacional del Sur, Bahia Blanca (Argentina). Instituto de Investigaciones Bioquimicas

    2003-07-01

    This study evaluates the effects of the radio inhibition process on garlic bulbs in terms of phase properties of microsomal membranes and their lipid and fatty acid composition. Garlic bulbs were irradiated with an average dose of 60 Gy of {sup 60}Co gamma rays 30-40 days after harvest. The treatment was carried out in the facilities of the National Atomic Energy Commission (CNEA). Rough and smooth microsomal membranes were isolated by ultracentrifugation from tissues of irradiated and non-irradiated storage leaves. Wide angle X-ray diffractograms of both fractions were recorded along 270 days of storage. Lipids were separated by thin layer chromatography. The fatty acid composition of major lipid fractions was studied by gas-liquid chromatography. The diffractograms featured peaks at Bragg spacing of 4.15 Armstrong and 3.75 Armstrong, revealing the presence of a gel (crystalline) phase, while the characteristic peak of the liquid-crystalline phase (4.6 Armstrong) was not observed in both sorts of membranes. Irradiation was found to bring about modifications in the intensity of 4.15 Armstrong and 3.75 Armstrong peaks from smooth microsomal membranes, but not in the behaviour along the studied period. Data from the rough microsomal fraction were erratic. Parallel to these changes, radiation induced significant modifications in the level of smooth microsomal membrane triacylglycerols in relation to phospholipids and their fatty acids. These findings indicate that the storage leaf tissues of garlic are radiosensitive both in terms of physical and chemical properties of their microsomal membranes. From the practical point of view, these results could be the basis for the development of techniques to be applied to storage garlic to evaluate if it was irradiated. (author)

  13. Degradation of polylactic acid (Pla) at different doses of gamma radiation; Degradacion del acido polilactico (PLA) a diferentes dosis de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Castillo R, Y.

    2015-07-01

    The excessive use of polymers such as polyethylene (PET), polystyrene (Ps) and recently the polylactic acid (Pla) that take more than 20 years to degrade, have caused great pollution in the environment. In this study the effects of gamma radiation in the Pla to different doses were studied, in order to reduce the degradation time of this polymer. The changes in physico-chemical structure of Pla during radiation were studied by thermo-gravimetric/Mass analysis; differential scanning calorimetry; scanning electron microscopy; X-ray dispersive analysis; infrared spectroscopy; X-ray diffraction and mechanical tests of hardness, elasticity and deformation. With scanning electron microscopy, the morphology of the Pla surface unirradiated was observed, in which an apparently smooth surface was observed, after changes that had the Pla when irradiated also was observed, where the effects of radiation were observed in form of scratch, agglomeration and small fractures. By X-ray dispersive analysis was determined and verified the elemental chemical composition of the Pla; as expected the tests showed only carbon, oxygen and hydrogen. With thermo-gravimetric/Mass analysis the decomposition temperatures of Pla were determined, identifying that the degradation compounds are CO, CO{sub 2} and CH{sub 4}. With infrared spectrometry the major peaks of Pla were observed before and after being irradiated with increasing of radiation dose the intensity of the bands decreased. Also by X-ray diffraction was observed that the polymer is an amorphous material. The mechanical tests indicate that the values of each of the tests decrease significantly with increasing the radiation dose. (Author)

  14. Sensory evaluation of a highly nutritive bread, formulated for populations suffering food emergencies, preserved with ionizing radiation; Evaluación sensorial de un panificado de alto valor nutricional formulado para poblaciones en emergencia alimentaria, preservado por radiaciones ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, G. S.; Gómez, B., E-mail: gabygon22@yahoo.com.ar, E-mail: bgomez@fb.uner.edu.ar [Universidad Nacional de Entre Ríos, Gualeguaychú (Argentina); Cova, M. C.; Narvaiz, Patricia [Comisión Nacional de Energía Atómica, Ezeiza (Argentina). Gerencia de Área Aplicaciones de la Tecnología Nuclear, Gerencia de Aplicaciones y Tecnología de Radiaciones, Sector Irradiación de Alimentos

    2011-07-01

    with 6 kGy of gamma radiation, keeping its sensory acceptability. This treatment would render a meal that is safe, stable at room temperature and humidity, without chemical preservatives, low cost as far as its ingredients is concerned, easy to handle, store and deliver. (author) [Spanish] Texto completo: El objetivo de este trabajo fue evaluar, mediante análisis sensorial, la factibilidad de prolongar mediante radiaciones ionizantes la vida útil a temperatura ambiente de un producto panificado de alto valor nutricional, especialmente formulado para personas en situación de emergencia alimentaria, tales como inundaciones, terremotos, aislamiento geográfico, o desnutrición. El tiempo de conservación de cualquier panificado se ve limitado por el desarrollo microbiano, motivo por el cual la industria emplea conservantes químicos para retrasarlo, y en ciertos casos, también refrigeración. Se diseñaron y elaboraron 21 formulaciones de panificados empleando harinas de trigo y de soja, lactosuero, huevo, aceite vegetal, leche descremada, agua, y algunos aditivos comerciales emulsificantes y de retención de la humedad. Mediante evaluaciones sensoriales preliminares se seleccionó una formulación. Se realizaron estimaciones bibliográficas del contenido y calidad nutricional de este panificado en comparación con uno convencional de trigo, evidenciándose mejoras en vitaminas y minerales, proteínas , grasas , y fibra. Se elaboraron y hornearon 40 panes de 450 g , a 220ºC durante 20 minutos, se envasaron con película de polietileno de 100 micrones de espesor, e irradiaron en la Planta Semi- Industrial de Co-60 del Centro Atómico Ezeiza, de actividad cercana a 600.000 Ci, con dosis de 6 y 10 kGy , velocidad de dosis de 10 kGy/h , uniformidad de dosis promedio de 1,1 kGy , medidas con dosímetro de dicromato de potasio y de plata por el sector Dosimetría de Altas Dosis (CNEA). Las dosis se seleccionaron considerando la literatura científica y an

  15. Effects of Gamma Radiation on Three Species of Philippine Insect Pests; Effets des rayons gamma sur trois especes d'insectes nuisibles des Philippines; Dejstvie gamma-izlucheniya na tri raznovidnosti nasekomykh-vreditelej na Filippinakh; Efectos de las radiaciones gamma sobre tres plagas insectiles de las Filipinas

    Energy Technology Data Exchange (ETDEWEB)

    Viado, G. B.; Manoto, E. C. [Philippine Atomic Energy Commission, National Science Development Board, Manila (Philippines)

    1963-09-15

    , sont moites sans avoir atteint le stade de la pupe. Les pupes se sont revelees plus resistantes que les larves et que les adultes. On n'est pas parvenu a une mortalite totale, meme avec 20 kr. Certains adultes apparus dans des lots irradies a 5 et 10 kr avaient des ailes et/ou des pattes anormalement developpees. Chez les adultes, les doses de 10 et 20 kr avaient des effets nocifs puisqu'elles aneantissaient, trois semaines apres l'irradiation, 75% environ des individus ayant ete soumis a la premiere dose et tous ceux qui avaient recu la seconde. On n'a pas constate de difference notable de sensibilite entre les sexes. Dans les lots ayant recu 60 et 80 kr, pres de 40% de S. oryzae mouraient une semaine apres l'irradiation, contre 10% seulement pour 20 kr et environ 20% pour 40 kr. Avec 40, 60 et 80 kr, la mortalite atteignait 75% deux semaines apres le debut de l'experience. Pour 10 kr, la mortalite au terme de la meme periode etait inferieure a 10% et pour 20 kr elle etait d'environ 25%. La dose de seuil semble se situer entre 20 et 40 kr. La mortalite de T. castaneum etait comparable a celle de S. oryzae si ce n'est que la dose seuil semble se situer aux environs de 40 kr. (author) [Spanish] Se han estudiado los efectos de las radiaciones gamma de una fuente de {sup 60}Co sobre tres insectos nocivos para la agricultura: 1) el escarabajo del tomate Epilachna philippinensis Dieke, que ataca al tomate y a la berenjena; 2) el gorgojo del arroz Sjtophilus oryzae L., y 3) el escarabajo de la harina Tribolium castaneum Herbst. Las dos ultimas especies son las plagas mas corrientes y destructivas del maiz y de otros granos y derivados de granos ensilados en las Filipinas. Los autores emplearon los huevos, larvas, ninfas e imagos del E. philippinensis en tomates, e imagos de S. oryzae y T. castaneum en el maiz. Con el Epilachna se ensayaron cuatro dosis de 1, 5, 10 y 20 kr. Con las otras dos especies se ensayaron cinco dosis de 10, 20, 40, 60 y 80 kr. Tras una dosis de 1 kr

  16. In vitro development of buds from tubers of (Solanum tuberosum L.); Desarrollo in vitro de yemas procedentes de tuberculos de patata (Solanum tuberosum L.) tratados por radiacion GAMMA

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Gonzalez, J; Garcia Collantes, M A

    1976-07-01

    The present work studies the in vitro development of buds from potato tubers subjected to gamma radiation at doses of 3, 6, 9 and 12 Krad. Ths effect of radiation was dependent on the dormant stage of the buds. Intermediate doses (6-9 Krad) did inhibit mitotic division but not cellular elongation. When irradiation is carried out at the end of the resting period, there is an apparent sprouting due to the elongation of previously formed cells. (Author) 17 refs.

  17. Las radiaciones ionizantes: una realidad cotidiana

    Directory of Open Access Journals (Sweden)

    Eduardo Gallego Díaz

    2010-12-01

    Full Text Available Este trabajo introduce la naturaleza de las sustancias radiactivas y de la radiación ionizante, los efectos que causa sobre la materia y los medios disponibles para su detección y medida, así como las fuentes de radiación naturales a las que los seres humanos estamos expuestos. Seguidamente, en el apartado más amplio del trabajo, se describen las múltiples aplicaciones de las radiaciones ionizantes en la medicina, la agricultura, la industria, las ciencias de la tierra, la biología y otras ramas, lo que permite poder poner su impacto en perspectiva frente al de las fuentes naturales. La tesis final del artículo es que para evitar sufrir daños resulta necesario protegerse adecuadamente de los efectos nocivos de la radiación y las sustancias radiactivas, pero sin limitar innecesariamente su utilización beneficiosa en los numerosos ámbitos descritos. Ese es el objetivo fundamental de la protección radiológica, cuyos principios básicos se presentan para terminar.

  18. System for Comparing Gamma Sources Varying by Ratios of up to 1:1000; Dispositivo Gamma que para Comparar Fuentes Difieren Hasta uno En Mil

    Energy Technology Data Exchange (ETDEWEB)

    Tejera Rivera, A.; Navarro Cuevas, D. [Universidad Nacional Autonoma de Mexico, Mexico D.F. (Mexico)

    1967-03-15

    Two nonelectronic devices have been constructed permitting continuous and reasonably accurate amplification by a factor of up to 100 of the counting capacity of a scintillation system. This system is designed for use in comparing the activities of radiation sources, mainly of the gamma type, and also the activities of one and the same radioisotope, when they differ by a ratio of the order 1:1000. The immediate use of the system is in the preparation of gamma standards for the calibration of ionization chambers requiring radioisotope (e. g. {sup 60}Co and {sup 131}I) activities in millicuries, on the basis of corresponding standards with activities of the order of microcuries. The basic principle involved is to limit the passage of light through the scintillation crystal to the photomultiplier tube. In the first device, half the face of the Nal(Tl) scintillation crystal and half the face of the photomultiplier are screened in such a way that rotation of the crystal causes the screens to be superimposed and the amount of light is cut down by from 50% to nil. With this device, it has been possible in practice to compare activities varying by 1:20. The second device is fitted with five diaphragms on a rotating disk which permit the passage of light to be regulated from 100% to nil. Using this device, it is possible to compare sources varying in activity by ratios of up to 1:1000, keeping the scaler reading within the limits of 100 000 counts/min. The main advantage to this procedure is that error due to differences in counter dead time for counts on sources varying widely in activity is reduced; further, samples of this kind can be compared using small-size shielding. (author) [Spanish] Se han construido dos dispositivos no electronicos que permiten ampliar hasta 100 veces, de manera continua y con buena exactitud, la capacidad de recuento de un equipo de centelleo. La finalidad de este dispositivo es la comparacion de las actividades de fuentes de radiacion

  19. Determination of radiation levels by neutrons in an accelerator for radiotherapy; Determinacion de niveles de radiacion por neutrones en un acelerador para radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Paredes G, L.; Salazar B, M.A. [Instituto Nacional de Investigaciones Nucleares, Apdo. Postal 18-1027, 11801 Mexico D.F. (Mexico); Genis S, R. [Fundacion Clinica Medica Sur, Puente de Piedra 150, Col. Torriello Guerra, Tlalpan 14050, Mexico D.F. (Mexico)

    1998-12-31

    It was determined the radiation levels by neutrons due to photonuclear reactions ({gamma}, n) which occur in the target, levelling filter, collimators and the small pillow blinding of a medical accelerator Varian Clinac 2100C of 18 MeV, using thermoluminescent dosemeters UD-802AS and US-809AS. The experimental values were presented for the patient level, inside and outside of the radiation field, as well as for the small pillow. (Author)

  20. Gamma-ray decontamination of a milk substitute for calf feeding; Descontaminacion de un sustituto lacteo para terneros por radiaciones gamma

    Energy Technology Data Exchange (ETDEWEB)

    Blasco, M I [Canale SA, Buenos Aires (Argentina); Roberti, A [Universidad Nacional de Lujan (Argentina); Horak, Celina I; Narvaiz, Patricia; Kairiyama, Eulogia [Comision Nacional de Energia Atomica, Ezeiza (Argentina). Dept. de Aplicaciones Tecnologicas y Agropecuarias

    1999-07-01

    A contaminated milk substitute for calf feeding has been irradiated to reduce the content of bacteria and fungi. The results of microbiological, chemical and physico-chemical studies demonstrate that an irradiation doses of 7 kGy reduce to an acceptable level the content of contaminants without damaging the milk substitute. (author)

  1. Application of spectroscopic methods to the study of ionizing radiation effects in polymers; Aplicacion de metodos espectroscopicos para estudiar efectos de la radiacion en polimeros

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez P, G

    1996-12-31

    In general the interaction of ionizing radiation with polymers generates physic-chemical changes. Aiming to quantity these changes, three spectroscopic analytical techniques were used (UV, IR and EPR) and the chemical corrosion technique was used for three DSTN (CR39, Lexan and Makrofol) which were exposed to two radiation types: electrons and gammas. The effects of radiation are compared. Also a correlation between the UV and Vg results in function of dose is presented. The possible causes of the increase in chemical corrosion are discussed. (Author).

  2. Training Programs on Radiological Safety for users of Ionizing Radiations in Peru; Programas de formacion en proteccion radiologica para usuarios de radiaciones ionizantes en el Peru

    Energy Technology Data Exchange (ETDEWEB)

    Medina Gironzini, E.

    2003-07-01

    In Peru, people who work with ionizing radiations must have an authorization (Individual License) as established in the Radiological Safety Regulations, which are the mandatory rules. The Technical Office of the National Authority (OTAN), which is the technical organ of the Peruvian Institute of Nuclear Energy (IPEN) in charge of controlling radiations within the country, grants the authorization after the candidate demonstrates that he/she knows the specific use of the technique using radiations, as well as the aspects related to safety and radiological protection. Since it was created in 1972, the Superior Center of Nuclear Studies (VSEN) from IPEN has carried out different training courses so that people can work safety with ionizing radiations in medicine, industry and investigation. The analysis of the radiological safety programs carried out by CSEN during the last 30 years, which allowed the training of more than 2200 people in the country and, at the same time, made possible the securing of the respective Individual License, is presented in this work. The courses, nuclear medicine, radiotherapy, industrial radiography, nuclear gauges gamma irradiator, etc..., are part of the continuous education program of CSEN. (Author)

  3. Action of the chlorophyllin on the genetic damage induced by gamma radiation in germinal cells of Drosophila Melanogaster; Accion de la clorofilina sobre el dano genetico inducido por radiacion gamma en celulas germinales de Drosophila Melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Cruces, M.P.; Pimentel, A.E.; Moreno, A.; Moreno, R. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The obtained results using somatic cells, they have evidenced that the chlorophyllin (CHLN) it can act inhibiting or increasing the damage caused by different mutagens. The objective of this investigation is to evaluate the effect of the CHLN on the damage induced by gamma radiation in germinal cells of Drosophila. Two tests were used, the lost of the X chromosome and the conventional test of lethal recessive bound to the sex (LRLS); both with a system of litters. The obtained results in both essays, indicated that the CHLN doesn't reduce the damage induced by the gamma radiation in none of the cellular monitored states. (Author)

  4. Action of the chlorophyllin on the genetic damage induced by gamma radiation in germinal cells of Drosophila Melanogaster; Accion de la clorofilina sobre el dano genetico inducido por radiacion gamma en celulas germinales de Drosophila Melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Cruces, M P; Pimentel, A E; Moreno, A; Moreno, R [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2003-07-01

    The obtained results using somatic cells, they have evidenced that the chlorophyllin (CHLN) it can act inhibiting or increasing the damage caused by different mutagens. The objective of this investigation is to evaluate the effect of the CHLN on the damage induced by gamma radiation in germinal cells of Drosophila. Two tests were used, the lost of the X chromosome and the conventional test of lethal recessive bound to the sex (LRLS); both with a system of litters. The obtained results in both essays, indicated that the CHLN doesn't reduce the damage induced by the gamma radiation in none of the cellular monitored states. (Author)

  5. Variations observed in the respiratory activity of potato tubers (Solanum tuberosum L.) after a treatment with gamma radiation; Variaciones observadas en la actividad respiratoria de tuberculos de patata (Solanum tuberosum L.) despues de un tratamiento con radiacion GAMMA

    Energy Technology Data Exchange (ETDEWEB)

    Mazon Matanzo, M P; Fernandez Gonzalez, J

    1976-07-01

    The present work studies the variations in the respiratory activity of irradiated and IPC treated potato tubers during a storage period of five months. By immediate effect of gamma radiation we can observe an increase in the oxygen consumption of the parenchyma in relation with the control tubers, such increase persists even fours months after gamma radiation. The respiratory activity is reduced in the IPC treated tubers. In the tissues cultivated in vitro the respiratory activity increases at the end of the cultivation period, not only in the control tissues but also in the irradiated ones, though this increase is greater in the control tissues. (Author) 15 refs.

  6. Isolation of Bacillus subtilis as indicator in the disinfection of residual water by means of gamma radiation; Aislamiento de Bacillus subtilis como indicador en la desinfeccion de aguas residuales mediante radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mata J, M; Colin C, A [Facultad de Quimica, UAEM, Paseo Colon esq. Tollocan s/n, Toluca, 50000 Estado de Mexico (Mexico); Lopez V, H; Brena V, M; Carrasco A, H; Pavon R, S [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    In the attempt to get more alternatives of disinfection of residual water, the Bacillus subtilis was isolated by means of gamma radiation as a bio indicator of disinfection since it turned out to be resistant to the 5 KGy dose, comparing this one with other usual microorganisms as biondicators like E. coli and S typhimurium which turn out more sensitive to such dose. (Author)

  7. Radiosensitizing effect of nitric oxide in tumor cells and experimental tumors irradiated with gamma rays and proton beams; Efecto radiosensibilizador del oxido nitrico en celulas tumorales y en tumores experimentales irradiados con radiacion gamma y con haces de protones

    Energy Technology Data Exchange (ETDEWEB)

    Policastro, Lucia L; Duran, Hebe; Molinari, Beatriz L [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Radiobiologia; Schuff, Juan A; Kreiner, Andres J; Burlon, Alejandro A; Debray, Mario E; Kesque, Jose M; Ozafran, Mabel J; Vazquez, Monica E [Comision Nacional de Energia Atomica, General San Martin (Argentina). Dept. de Fisica; Davidson, Jorge; Davidson, Miguel [Consejo Nacional de Investigaciones Cientificas y Tecnicas (CONICET), Buenos Aires (Argentina); Somacal, Hector R; Valda, Alejandro A [Universidad Nacional de General San Martin , Villa Ballester (Argentina). Escuela de Ciencia y Tecnologia

    2003-07-01

    Nitric oxide (NO) has been reported to be a radiosensitizer of mammalian cells under hypoxic conditions. In a previous study, we demonstrated an enhancement in radiation response induced by NO in mouse tumor cells under aerobic conditions, with an increasing effect as a function of malignancy. The aim of the present study was to evaluate the effect of NO in tumor cells and in experimental tumors irradiated with {gamma} rays and proton beams. Irradiations were performed with a {sup 137}Cs {gamma} source and with proton beams generated by the TANDAR accelerator. Tumor cells were treated with the NO donor DETA-NO and the sensitizer enhancement ratio (SER) was calculated using the {alpha} parameter of the survival curve fitted to the linear-quadratic model. Tumor cells irradiated with protons were radio sensitized by DETA-NO only in the more malignant cells irradiated with low LET protons (2.69{+-}0.08 keV/{mu}m). For higher LET protons there were no radiosensitizing effect. For human tumor cells pre-treated with DETA-NO and irradiated with {gamma} rays, a significantly greater effect was demonstrated in the malignant cells (MCF-7) as compared with the near normal cells (HBL-100). Moreover, a significant decrease in tumor growth was demonstrated in mice pre-treated with the NO donor spermine and irradiated with {gamma} rays and low LET protons as compared with mice irradiated without pre-treatment with the NO donor. In conclusion, we demonstrated a differential effect of NO as a radiosensitizer of malignant cells, both with {gamma} rays and low LET protons. This selectivity, coupled to the in vivo inhibition of tumor growth, is of great interest for the potential use of NO releasing agents in radiotherapy. (author)

  8. Compounds Labelled with Low-Energy Gamma-Ray Emitters for Medical Isotope Scanning; Gammagraphie au Moyen de Composes Marques avec des Emetteurs Gamma de Faible Energie; Soedineniya, ispol'zuemye pri meditsinskom izotopnom skennirovanii, mechennye s pomoshch'yu gamma-izluchatelej nizkoj ehnergii; Compuestos Marcados con Emisores Gamma de Baja Energia para la Exploracion Medica Mediante Isotopos

    Energy Technology Data Exchange (ETDEWEB)

    Scheer, K. E.; Zum Winkel, K.; Georgi, M. [Czerny-Krankenhaus der Universitat Heidelberg, Federal Republic of Germany (Germany)

    1964-10-15

    detecter de petites lesions. 2. L'absorption du rayonnement par les tissues limite la profondeur a laquelle les lesions sont 'visibles'. Dans de grands organes comme le foie, on evite la superposition des rayonnements provenant de la partie posterieure de l'organe, d'ou une meilleure detection des lesions superficielles. Le plus important emetteur gamma de faible energie est l'iode-125. Pour l'exploration de la thyroiede on l'utilise sous forme d'iodure. Pour le foie, le rose bengale marque avec {sup 125}I convient parfaitement, mais on peut aussi utiliser de l'albumine alteree par la chaleur et marquee avec {sup 125}I. Pour le rein, on a constate que l'hippuran marque avec {sup 125}I donne de bons resultats en injection intra-musculaire, si on le melange a de l'hyaluronidase pour assurer un niveau uniforme de radioactivite dans cet organe. Un autre emetteur gamma de faible energie tres utile en gammagraphie est le mercure-197, qui peut etre utilise sous forme de chlorure pour l'exploration du rein et de la rate. On doit prendre des precautions speciales pour eviter la superposition de ces organes. On obtient un meilleur scintigramme avec de la neo- hydrine marquee avec {sup 197}Hg; ce produit peut servir aussi a localiser les tumeurs du cerveau. Les auteurs donnent des details sur des cas typiques d'exploration de tumeurs de la thyroiede, du foie, de la rate, du rein et du cerveau, d'une part avec des emetteurs gamma de faible energie et d'autre part avec des nucleides et des composes classiques; ils comparent les resultats obtenus. (author) [Spanish] Los emisores gamma de baja energia presentan ventajas especiales para la exploracion medica por centelleografia. He aquilas razonest . 1. El blindaje de plomo de los colimadores es mucho mas eficaz. Por tanto, pueden utilizarse colimadores enfocados con canales de tabiques delgados, lo que da un mayor grado de resolucion geometrica y permite, por consiguiente, detectar lesiones'mas pequenas. 2. La absorcion de la radiacion

  9. Effect of gamma radiation on the meristematic activity of garlic (Allium sativum L. ) bulbs; Efecto de la radiacion gamma sobre la actividad meristematica de bulbos de ajo (Allium sativum L.)

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, J; Aparicio, C

    1979-07-01

    The effect of 10 krad of gamma radiation on the sprouting and mieristematic activity of garlic bulbs is studied. Results show that the Irradiation inhibits the meristematic activity of the bulbs independently of the epoch of treatment. When the treatment is applied several months after harvest (five or more), some apparent sprouting could be detected. This is due to a cellular elongation process rather than to cellular divisions. (Author) 47 refs.

  10. Gamma radiation effects on nano composites of Ag nanoparticles in Zn O matrices; Efectos de la radiacion gamma en nanocompositos de nanoparticulas de Ag en matrices de ZnO

    Energy Technology Data Exchange (ETDEWEB)

    Villasenor C, L. S.

    2015-07-01

    The study of gamma radiation effects in nano composites of silver nanoparticles in a Zn O matrix has been performed in this work. First, silver nanoparticles (AgNPs) were synthesized by colloidal methods, with two different mean average sizes, 48 nm and 24 nm respectively. These nanoparticles were characterized by transmission electron microscopy (Tem) and UV-Vis spectroscopy (UV-Vis). Then, with the synthesized AgNPs, nano composites in a matrix of Zn O were prepared. The first nano composite was prepared with the 48 nm AgNPs at 9.5 weight % of silver (Ag) and the second nano composite with the 24 nm nanoparticles at 1.0 weight % of Ag. Both nano composites were analyzed by scanning electron microscopy (Sem). The formation of the Zn O phase in the nano composite was corroborated through X-ray diffraction analysis. It was observed that the presence of AgNPs during the formation of the AgNPs/Zn O nano composite modified the size and morphology of the structures obtained compared to those of the pure Zn O without nanoparticles, however both exhibit a radial structure. Then, the nano composite at 9.5 weight % of Ag was irradiated with gamma rays at doses of 1, 20 and 50 kGy. Samples were analyzed by Sem and the Bet technique, before and after being irradiated, in order to determine the effect of gamma radiation in the morphology, porosity and surface area of the studied material. Even when there are changes in porosity and Surface area, this difference is not very significant for some applications, however it will have to be considered during the design of a specific application of the nano composites. On the other hand, no morphology modifications were identified on the samples irradiated at the studied doses, with the electron microscopy techniques used. (Author)

  11. Effects of temperature and gamma radiation on the stability of 125{sub -}19-Iodo cholesterol; Efectos de la temperatura y la radiacion gamma sobre la estabilidad dle 19-Yodocolestero. 125 I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L.; Rebollo, D. V.; Ruiz, J. M.

    1986-07-01

    He have studied the effect of the temperature and the gamma radiations on the I25I-19-iodocholesterol synthesized in our laboratory; the time of caducity (t 90) have been fixed from the rate constants of decomposition (k) (20,9) 32,1 y 144 . 10-3 h''-1) for different temperatures (35, 50 y 75degree centigree), and the value of Go(-M) (1,52) by radiation of samples of 19-Iodocholesterol-I25 I (0,94 mg/ml) with 60co (0,177 Hrad/h) . (Author) 8 refs.

  12. Effect of gamma radiation on starch content and cellular morphology of Chlorella pyrenoidosa; Efecto de la radiacion gamma sobre el contenido en almidon y la morfologia celular de Chlorelia pyrenoidosa

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C; Fernandez, J

    1983-07-01

    The effect of five doses of gamma radiation (10, 100, 500, 1000 and 5000 Gy) on starch content and fine structure of Chlorella pyrenoidosa has been studied. Results show the accumulation of large amounts of starch on Chlorella cells after irradiation at 500, 1000 and 5000 Gy doses. The starch which is stored in the cytoplasm in form of great grains produces a de organization of the chloroplast structure, observed by electron microscopy techniques. The microphotographs presented also show a significant increase in the cellular size after irradiation up to 500 Gy. (Author) 29 refs.

  13. Influence of temperature in TL signal induced by gamma radiation in zircon prepared by sol gel via; Influencia de la temperatura en la senal TL inducida por la radiacion gamma en zirconia preparada via solgel

    Energy Technology Data Exchange (ETDEWEB)

    Salas, P.; Castano, V.M. [Instituto de Fisica, UNAM, Laboratorio Juriquilla, A.P. 1-1010, 76001 Queretaro (Mexico); Mendoza A, D.; Gonzalez M, P.R. [ININ, Mexico, D.F. (Mexico); Rosa C, E. de la [Centro de Investigaciones en Optical, Leon, Gto. (Mexico)

    2000-07-01

    In this work, it was realized a study of the temperature effects in thermoluminescent signal (Tl) induced by gamma radiation in zircon, which was prepared by the sol gel method. According to the obtained results, the zircon thermically treated at 500 C or over is sensitive to radiation. This sensitivity is increased when the temperature in study is augmented, moreover, the Tl spectra form also is modified with the temperature increment. The samples thermically treated at 750 C or over present a linear response in the dose interval 27 to 165 Gy; therefore, such materials result promissories for dosimetric purposes. (Author)

  14. Thermoluminescent characterization of thin films of aluminium oxide submitted to beta and gamma radiation; Caracterizacion termoluminiscente de peliculas delgadas de oxido de aluminio sometidas a radiacion beta y gamma

    Energy Technology Data Exchange (ETDEWEB)

    Villagran, E.; Escobar A, L.; Camps, E.; Gonzalez, P.R.; Martinez A, L. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2002-07-01

    By mean of the laser ablation technique, thin films of aluminium oxide have been deposited on kapton substrates. These films present thermoluminescent response (Tl) when they are exposed to beta and gamma radiation. The brilliance curves show two peaks between 112 C and 180 C. A dose-response relationship study was realized and the Tl kinetic parameters were determined using the computerized deconvolution of the brilliance curve (CGCD). The thin films of aluminium oxide have potential applications as ultra.thin radiation dosemeters. (Author)

  15. Effects of temperature and gamma radiation on the stability of 125{sub -}19-Iodo cholesterol; Efectos de la temperatura y la radiacion gamma sobre la estabilidad dle 19-Yodocolestero. 125 I

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez, L; Rebollo, D V; Ruiz, J M

    1986-07-01

    He have studied the effect of the temperature and the gamma radiations on the I25I-19-iodocholesterol synthesized in our laboratory; the time of caducity (t 90) have been fixed from the rate constants of decomposition (k) (20,9) 32,1 y 144 . 10-3 h''-1) for different temperatures (35, 50 y 75degree centigree), and the value of Go(-M) (1,52) by radiation of samples of 19-Iodocholesterol-I25 I (0,94 mg/ml) with 60co (0,177 Hrad/h) . (Author) 8 refs.

  16. Effect of the gamma radiation in the metabolic activity of the apical meristem of asparagus (Asparagus officinalis); Efecto de la radiacion gamma en la actividad metabolica del meristemo apical de esparrago (Asparagus officinalis)

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez E, A.; Orozco A, J.A.; Troncoso R, R.; Ojeda C, A.J.; Mercado R, J.N.; Gardea B, A.; Tiznado H, M.E. [Centro de Investigacion en Alimentacion y Desarrollo, A.C. Carretera a la Victoria km. 0.6, A.P. 1735, Hermosillo, Sonora (Mexico); Melendrez A, R. [Universidad de Sonora, A.P. 5-088, Hermosillo, Sonora (Mexico)]. e-mail: aestrada@cascabel.ciad.mx

    2007-07-01

    The asparagus (Asparagus officinalis) is an agricultural product whose production generates a great quantity of wages as well as foreign currencies for the country because a great part of its production is exported to international markets. In direct reason to the high metabolic activity of the apical meristem, this product it possesses a short shelf life under good conditions of commercialization. Due to the above mentioned, the present work had as objective to evaluate the effect of the gamma radiation in the metabolic activity of the apical meristem of turions of asparagus during the postharvest. Turions of asparagus variety Brock of standard quality was treated with gamma radiation to absorbed dose of 1.0, 1.5, 2.0, 2.5 and 3.0 kGy using an irradiator of {sup 60}Co and stored in one controlled temperature camera maintained at 2 C during 8 days. During the experiment, the camera stayed in darkness and under conditions of high relative humidity by means of the water aspersion. Immediately before the one treatment and after 1, 2, 4 and 8 days of storage, the asparagus were sampled to evaluate the breathing speed (VRCG) by means of gas chromatography and scanning differential calorimetry (VRCDB), ethylene production (PE) by means of gas chromatography and production of metabolic heat of the apical meristem of the asparagus by means of scanning differential calorimetry (Q). Its were not found effects due to the gamma radiation in the variables of VRCG, VRCDB and Q. However, for the PE case, it was found that the doses of 1.5 and 2.5 reduced the PE from the first day of storage, while the 3 kGy dose achievement to eliminate completely the ethylene production from the first day of storage. It was concluded that the gamma radiation at the used levels in the present experiment doesn't reduce the metabolic activity of the apical meristem of the turion of asparagus although it can to improve the postharvest quality from the asparagus when reducing the ethylene

  17. Action of the chlorophyllin before genetic damage induced by gamma radiation in germinal cells of Drosophila; Accion de la clorofilina ante el dano genetico inducido por radiacion gamma en celulas germinales de Drosophila

    Energy Technology Data Exchange (ETDEWEB)

    Moreno B, R

    2004-07-01

    The chlorophyllin (CHLN) is a porphyrin of nutritious grade and soluble in water, derived of the chlorophyll. It has been reported that this pigment is a good anti mutagen since it reduces the damage to the DNA caused by physical or chemical agents of direct or indirect action. Their anti carcinogenic action has also been demonstrated when it is administered itself during the induced post-initiation phase by aflatoxins and heterocyclic amines. However in the last decade it has been reported that it also has promoter activity against the genetic damage induced by diverse agents like the alkyl ants of direct and indirect action, the gamma radiation and some heterocyclic amines. This effect has been observed in testing systems like Salmonella, Drosophila, rainbow trout and rodents. In the mouse spermatogonia it has been reported that it reduces the damage to the DNA but with the test of lethal dominant in Drosophila increment the damage induced by gamma radiation. The present study consisted on evaluating the effect of the CHLN in the line germinal masculine of Drosophila by means of the lethal recessive test bound to the sex (LRLS) with the stump Muller 5 and a litters system. Its were pretreated wild males with CHLN and 24 h later were irradiated with 0, 10, 20 and 40 Gy of gamma radiation immediately later were crossed with virgin females of the stump Basc and at 72 h the male was transferred to a cultivation media with three new virgin females, this process repeated three times until completing 3 litters. The F1 it was crossed among itself and in the F2 it was analysed the presence or absence of lethals. The results indicated that the CHLN per se incremented the basal frequency of damage due to the pigment can act as an agent that is inserted to the ADN causing pre mutagenic leisure. Nevertheless with the groups treated with the different doses of gamma radiation the CHLN does not present any protector action, neither promoter except in the litter I of the group

  18. Modifier activity of the protoporphyrin IX of the clastogenic damage induced by gamma radiation in Drosophila melanogaster; Actividad modificadora de la protoporfirina IX del dano clastogenico inducido por radiacion gamma en Drosophila melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Martinez A, G. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    It has been demonstrated that the copper sodium chlorophyllin (CCS) it is a potent inhibitor of the one genetic damage induced by physical or chemical agents in systems like: bacteria, Drosophila, rainbow trout and mammals. Nevertheless it has been observed that under certain conditions it promotes it. In the laboratory of Drosophila of the ININ evidences have been obtained that the CCS increases the percentage of lethal embryonic dominant and post-embryonic induced by gamma radiation. One of the probable causes of this effect promoter, is the oxidizer stress that it could cause the metallic center of the CCS. The objective of this investigation it was the evaluation of the inhibitory action of the protoporphyrin IX (PP-IX) of the genetic damage induced by gamma radiation in the germinal line of Drosophila melanogaster. For such effect it was used the lethal dominant test by means of two protocols: one in the one that the PP-IX or CCS was administered to the females and the other one to the males. Females of genotype y/y and males of the canton-S stump were used. In both cases the males were treated with 40 Gy of gamma radiation. Its were count the embryonic lethal dominant (L-E) and those post-embryonic (L-PE) of the F1. The results indicated that after the one pretreatment with PP-IX to the crossed females with males treaties increase the percentage of L-E (P {<=} 0.001) and it diminished that of L-PE (P {<=} 0.001) compared with the sucrose control more radiation, however when it was pretreated with CCS also it was observed an increment in the percentage of L-E (P {<=} 0.001), but it doesn't present effect on that of L-PE. In contrast, when the males were pretreated, it was observed that the PP-IX tends to increase those L-E, but diminished the L-PE (P {<=} 0.05), however when it was pretreated with CCS was observed that increased the percentage of L-E (P {<=} 0.001) but diminished that of L-PE (P {<=} 0.001). It was concluded that none of the two pigments

  19. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J; Mijares O, P; Garcia A, J M [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  20. Effect of gamma radiation on chlorophylls content, net photosynthesis and respiration of Chlorella pyrenoidosa; Efecto de la radiacion gamma sobre la fotosintesis neta y la respiracion de Chlorella pyrenoidosa

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C; Fernandez, J

    1983-07-01

    The effect of five doses of gamma radiation: 10, 100, 500, 1000 and 5000 Gy on chlorophylls content, net photosynthesis and respiration of Chlorella pyrenoidosa has been studied. A decrease in chlorophylls levels is produced after irradiation at 500, 1000 and 5000 Gy, being, at first b chlorophyll affected to a greater extent than a chlorophyll. Net photosynthesis and respiration decline throughout the time of the observation after irradiation, this depressing effect being much more remarkable for the first one. Met photosynthesis inhibition levels of about 30% are got only five hours post irradiation at a dose of 5000 Gy. Radio estimation by low doses, although obtained in some cases for tho 10 Gy dose, has not been statistically confirmed. (Author) 23 refs.

  1. Participation of different genes in the ruptures repair of double chain in Escherichia coli stumps exposed to gamma radiation; Participacion de diferentes genes en la reparacion de rupturas de doble cadena en cepas de Escherichia coli expuestas a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Serment G, J. H.; Martinez M, E.; Alcantara D, D., E-mail: jorge.serment@inin.gob.mx [ININ, Departamento de Biologia, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-05-01

    All living organisms are naturally exposed to radiation from different sources. Ionizing radiation produces a plethora of lesions upon DNA that can be categorized as single and double strand breaks and base damage. Among them, unrepaired double strand breaks (Dbs) have the greatest biological significance, since they are responsible of cell death. In Escherichia coli this kind of lesions are repaired mostly by homologous recombination. In this work the participation of some recombination genes in the repair of Dbs is evaluated. Escherichia coli defective strains were exposed to gamma radiation and incubated for different periods in ideal conditions. Both micro electrophoresis and pulse field gel electrophoresis techniques were used to evaluate the kinetics of repair of such lesions, reflecting the importance of each defective gene in the process. (Author)

  2. Evaluation of the quality of hot air dehydrated onion coming from gamma radiated bulbs; Evaluacion de la calidad de cebolla deshidratada por aire caliente proveniente de bulbos tratados con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Elman, L; Pezzutti, A; Croci, C A [Universidad Nacional del Sur, Bahia Blanca (Argentina). Laboratorio de Radioisotopos

    2003-07-01

    The purpose of this work was to evaluate the quality of hot air dehydrated onion, as regards physical and chemical characteristics, coming from the regional product that was gamma irradiated for sprout inhibition. We worked with the onion variety Valenciana Sintetica 14. Radio inhibition was made 30 days post harvest with gamma radiation from a {sup 60}Co source at the Centro Atomico Ezeiza-CNEA, using a dose of 60 Gy. The skin of the bulbs was manually removed and the bulbs were cut in pieces 3 mm thick and between 1 and 3 cm long. The material was dehydrated in a rotating dryer with forced air circulation at 60 C degrees, between 0.8 and 1.7 m/s air speed and at ambient relative humidity. Dehydration was made 80 days after post-irradiation. The quality of the dehydrated onion was evaluated by the following physical- chemical analysis: total solids content, pungency (indirectly measured by pyruvic acid content assessment), color, pH, carbon hydrates and sensorial analysis. All analytical determinations were made in triplicate. The results obtained showed there are no significant changes between the averages of the physical-chemical properties of the control dehydrated samples and those coming from the radio-inhibited raw matter. According to the sensorial analysis, only the color of dehydrated onion was affected by the radio inhibition process. However, and according to the panel members comment, the greatest browning degree observed in ionizing radiation treated onion seemed to result more attractive to them. It may be concluded that radio inhibited regional onion can be useful as raw matter for hot air dehydrated product. It must be remarked that its use would extend the product use by dehydration plants, thus implying an increase of their processing capacity with the corresponding financial benefit. (author)

  3. Evaluation of fruit productivity and quality in Hass avocado submitted to {sup 60}Co gamma radiation; Evaluacion de productividad y calidad de fruta en aguacate Hass sometido a radiacion gamma de {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Cruz T, E. De la; Ibanez P, J.; Mijares O, P.; Garcia A, J.M. [Instituto nacional de Investigaciones Nucleares, Departamento de Biologia, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    Evaluation of productivity, postharvest behavior and fruit quality was performed on four years Hass avocado trees irradiated with {sup 60} Co gamma rays in doses of 5, 10, 15, 20 and 25 Gy, established in the ''La Labor'' Experimental Center of the Centro de Investigaciones Cientificas y Tecnologias del Aguacate en el Estado de Mexico (CICTAMEX) at Temascaltepec Mexico. Productivity had a significant increase in the dose of 15 Gy being the average number of fruits nearly 400 % more than the control at fruit setting, being such difference reduced at fruit harvesting to 300 %. In regard to postharvest performance, the respiration index (mg CO{sub 2}/kg/hr) did not show significant differences among treatments. Also others variables such as physiological weight losses, texture, maturity pattern, and sensorial tests (color, flavor, aroma, texture) were not different in regard to the control. This mean that radiation has altered productivity but not the quality and postharvest behavior of fruits. (Author)

  4. Microstructural characteristics of the hydroxyapatite and its influence in the Tl signal induced by gamma radiation; Caracteristicas microestructurales de la hidroxiapatita y su influencia en la senal Tl inducida por la radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.R.; Hernandez A, M. [ININ, A.P. 18-1027, 11801 Mexico D.F. (Mexico); Estrada G, R. [Depto. de Fisica y Matematicas, Universidad Iberoamericana, Santa Fe, 01000 Mexico D.F. (Mexico); Rodriguez L, V. [Centro Universitario de Vinculacion, BUAP, Puebla (Mexico)

    2003-07-01

    The analysis carried out on different materials has shown that the quantity and type of dopants play an important role in the behaviour thermoluminescent signal induced by the ionizing radiation. More recent studies have also shown that the grain size influences strongly in the thermoluminescent signal. Plus still, the crystal growth habit and the crystalline degree have an important effect in the type and intensity thermoluminescent signal. In this sense, we present this work on the analysis of the thermoluminescent signal induced by the gamma radiation in the hydroxyapatite ceramic. Depending the growth habit, a variation of the peak temperature location, signal intensity and linearity range was observed; in particular cases a lineal relationship between glow curve and radiation dose was in the range from 2 to 1000 Gray. These results are complemented with a microstructural and crystalline degree analysis through scanning electron microscopy and X-ray Diffraction. The dose-response over the whole irradiation range opening up the possibility of employing this bio material as a dosimeter. (Author)

  5. Manufacture of Wood-Plastic Combinations by Use of Gamma Radiation; Fabrication de combinaisons bois-matiere plastique a l'aide des rayons gamma; Proizvodstvo drevesno-plastmassovykh sostavov s pomoshch'yu gamma-izlucheniya; Impregnacion de maderas con materiales plasticos en presencia de radiaciones gamma

    Energy Technology Data Exchange (ETDEWEB)

    Kent, J. A.; Winston, A.; Boyle, W.; Updyke, L. [Engineering Experiment Station, West Virginia University, Morgantown, West Virginia (United States)

    1963-11-15

    brittleness over the unmodified wood. Data are presented fot hardness, elastic limit in compression, dimensional stability, static bending and shear. (author) [French] d'ethylene glycol, le dimethacrylate de polyethylene glycol, le dtanate de tetraisopropyle, le methacrylate d'allyle et le divlnyle benzene (pour lestyrene). Les essais mecaniques sur les combinaisons bois-matiere plastique montrent que la durete, la limite d'elasticite sous compression, la stabilite dimensionnelle, et certaines autres proprietes sont ameliorees. En revanche, la fragilite augmente. Les autens donnent des chiffres pour la durete, la limite d'elasticite sous compression, la stabilite dimensionnelle, la flexion et le cisaillement. (author) [Spanish] Los autores describen un proceso susceptible de aprovechamiento comercial para producir maderas impregnadas mediante el empleo de los rayos gamma. En este proceso cabe distinguir dos fases : la impregnacion de la madera con el monomero adecuado, y la polimerizacion in situ del monomero por irradiacion gamma. Se estudiaron los factores que ejercen influencia sobre la penetracion del monomero en la estructura de la madera; los ensayos realizados revelaron que, en la practica, es posible lograr una buena distribucion del polimero en el producto resultante. Los autores impregnaron muestras de hasta 4 pulg (10,1 cm) de espesor y 5 pies (1,52 m) de longitud, examinandolas para determinar su penetracion por el monomero, y sometieron con exito otras muestras de espesor analogo,:a un proceso de polimerizacion. El comportamiento de las maderas blandas es muy distinto del de las maderas duras por lo que se refiere a la penetracich del monomero. No obstante, resulta posible, dentro de ciertos limites, regular la absorcion del monomero a fin de alcanzar la concentracion deseada de polfmeros en diversas clases de maderas. La memoria reproduce curvas de conversion correspondientes a la radiopolimerizacion del metacrilato de metilo, acetato de vinilo y estireno en

  6. Nuevo dosímetro de zona programable para la medición y monitoreo operacional de la radiación gamma externa

    Directory of Open Access Journals (Sweden)

    Bárbara Fuentes González

    2011-03-01

    Full Text Available Normal 0 21 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso-bidi-language:#0400;} La detección y la medición de las radiaciones nucleares se han convertido en un importantísimo renglón en la aplicación de los detectores nucleares y específicamente los Geiger-Muller. Los tubos Geiger con una alta sensibilidad de detección, su robusta construcción y un simple circuito adjunto continúan siendo uno de los detectores más usados en todas las áreas de aplicación en la física e investigaciones nucleares. Se presenta un nuevo diseño de instrumento para medir  la tasa de dosis externa ambiental de radiación gamma desde 0.05µSv/h hasta 10mSv/h. Consta de tres elementos fundamentales: el detector Geiger-Muller, una tarjeta electrónica de adquisición y control y el software de aplicación. El instrumento se comunica a través de una interfase USB con la computadora solo para variar y ajustar los parámetros de la calibración. El software se desarrolló en lenguaje C utilizando el compilador PICC4.08. Normal 0 21 false false false MicrosoftInternetExplorer4 Normal 0 21 false false false MicrosoftInternetExplorer4 /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Tabla normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:10.0pt; font-family:"Times New Roman"; mso-ansi-language:#0400; mso-fareast-language:#0400; mso

  7. Mejoras prácticas para líneas de decoración Inkjet en cerámica. Máquina IR de radiaciones electromagnéticas (tecnología de longitud de onda

    Directory of Open Access Journals (Sweden)

    Gálvez, D.

    2012-04-01

    Full Text Available SACMI IBÉRICA, S.A., has been awarded by the Spanish Society of Ceramics and Glass (SECV, with one GOLD ALFA, in its 2012 edition, during CEVISAMA for the presentation of the innovative IR Electromagnetic Radiation Machine, which improves the conditions and the production performance of digital decoration lines INKJET and other decorative applications ceramic tile.

    SACMI IBÉRICA, S.A., ha sido galardonada por la Sociedad Española de Cerámica y Vidrio (S.E.C.V., con un ALFA DE ORO, en su edición 2012, durante la celebración de CEVISAMA, por la presentación de la innovadora Máquina IR de Radiaciones Electromagnéticas, que mejora las condiciones y rendimiento productivo de las líneas de decoración digital INKJET y también en otras aplicaciones decorativas en azulejos y baldosas cerámicas.

  8. Radioisotopes and Radiation in Animal and Plant Insect Pest Control; Emploi des radioisotopes et des rayonnements dans la lutte contre les insectes nuisibles aux plantes et aux animaux; Ispol'zovanie radioizotopov i radiashchi v bor'be s nasekomymi-vreditelyami rastenij i zhivotnykh; Utilizacion de los radioisotopos y de las radiaciones en la lucha contra los insectos nocivos para las plantas y los animales

    Energy Technology Data Exchange (ETDEWEB)

    Andreev, S. V.; Martens, B. K.; Samojlova, V. A.; Molchanova, Z. I. [Vsesoyuznyj Institut Zashchity Rastenij, Leningrad, SSSR (Russian Federation)

    1963-09-15

    rayonnements ionisants sur les micro-organismes entomopathogenes (Beauveria bassiana Unill.) a permis de demontrer la possibilite d'accroitre leur virulence et, partant, d'ameliorer la methode microbiologique de lutte contre les insectes nuisibles. L'action sterilisante et letale des rayonnements ionisants peut etre utilisee comme moyen actif de lutte contre ces insectes. On a determine les doses de sterilisation a l'aide des rayons gamma pour un certain nombre d'insectes ravageurs des recoltes stockees (Calandra granaria L., Acanthoscelides obtectus Say, Pectinophota malvella Hb, Leptinotarsa decemlineota Say, Chloridea obsoleta F.) et des semences. Les donnees obtenues a la suite des recherches permettront de mettre au point et de perfectionner les methodes de lutte contre les insectes nuisibles, notamment a l'agriculture. (author) [Spanish] El problema de la lucha contra los insectos daninos es de gran importancia para las economias nacionales. Los ultimos descubrimientos de la ciencia pueden contribuir considerablemente a resolverlo. A fin de emplear de una manera mas racional y eficaz los metodos de lucha contra las plagas de insectos, se ha recurrido a los radioisotopos y a las radiaciones. Los radioisotopos y las radiaciones son auxiliares muy utiles para mejorar los metodos de lucha contra los insectos daninos. Su empleo requiere un estudio detallado de toda una serie de cuestiones de bioecologfa, toxicologia, etc. En bioecologfa, la marcacion, de los insectos es una tecnica muy prometedora. El empleo de los radioisotopos a fin de marcar a los insectos daninos para los cultivos de cereales (Eurygaster integriceps de los radioisotopos a fin de marcar a los insectos daninos para los cultivos de cereales (Eurygaster integriceps Put, Hadena sordida Skh), y a sus parasitos ( Meniscus agnatus Crow, Pseudogonia cinerascens Rond) ha permitido calcular la extension de las migraciones, delimitar los reservorios, evaluar la importancia de las poblaciones y estudiar el modo de

  9. Radiaciones electromagnéticas

    OpenAIRE

    Borrero, Luis M.

    2010-01-01

    I-La luz; II-El infrarrojo; III-El ultravioleta; IV-Los rayos X. Los rayos gamma. Los rayos intermediarios o de Holweck. Las ondas cortas y las corrientes de alta frecuencia. ResumenIlustraciones: Los rayos cósmicos

  10. The Effects of Gamma Radiation on the Ovaries of Dacus Oleae Gmel; Effet des rayons gamma sur les ovaires de la Dacus Oleae Gmel; Vozdejstvie gamma-izlucheniya na yaichniki Dacus Oleae; Efecto de las radiaciones gamma sobre los ovarios de la Dacus Oleae Gmel

    Energy Technology Data Exchange (ETDEWEB)

    Baccetti, Baccio [Agricultural Entomology Station, Florence and Raffaella de Dominicis Radiological Institute, University of Florence (Italy)

    1963-09-15

    The authors have studied by cytological and ultramicroscopio techniques the ovaries of unfertilized adult females of Dacus oleae irradiated in the middle period of the pupal stage with several doses (2-30 kr) of gamma rays. In all cases the treatment inhibits the normal development of the ovary. Nurse cells and egg cells are very small and few in number and show abnormal stricture and ultrastructure, particularly as regards the cytoplasmic organelles. (author) [French] Les auteurs ont fait appel aux techniques cytologiques et ultramicroscopiques pour etudier les ovaires de femelles adultes de Dacus oleae non fecondees, qui avaient ete irradiees au milieu du stade pupaire par plusieurs doses (2-30 kr) de rayons gamma. Dans tous les cas, l'irradiation a empeche un developpement normal de l'ovaire. Les cellules nourricieres et les ovules etaient tres petits et rares, avec une structure anormale, surtout pour les organites du cytoplasme. (author) [Spanish] Los autores de la memoria han estudiado con tecnicas citologicas y ultramicroscopicas los ovarios de hembras adultas, no fertilizadas, de la Dacus oleae irradiadas durante el periodo medio de la fase ninfal con varias dosis de rayos gamma (de 2 a 30 kr). El tratamiento inhibe el desarrollo normal del ovario. Los oocitos, en todas sus fases, son muy pequenos, aparecen en escaso numero y muestran una estructura y ultraestructuca anormales, sobre todo por lo que respecta a los organulos citoplasmicos. (author) [Russian] Avtory izuchili s pomoshch'yu tsitologicheskikh i ul'tramikroskopicheskikh metodov yaichniki neollodotvorennykh khenskikh osobej Dacus oleae, obluchennykh, v seredine fazy okuklivaniya razlichnymi dozami (ot 2000 do 30 000 r) gamma-luchej. V kazhdom sluchae ehto tormozilo normal'noe razvitie yaichnikov. Pitayushchie i yajtsevye kletki byli ochen' malen'kimi, kolichestvo ikh neznachitel'no, struktura i ul'trastruktura nenormal'nye, prezhde vsego v otnoshenii. (author)

  11. Design and fabrication of shielding for gamma spectrometry; Diseno y fabricacion de blindaje para espectrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-05-15

    To have a system of gamma spectrometry in the Radiological Mobile Unit No. 1 (UMOR-1) was designed and manufactured an armor-plating appropriate to this, to make analysis of radioactive samples in place in the event of a radiological emergency, besides being able to give support to the Management of Radiological Safety, and even to give service of sample analysis of other Institutions. (Author)

  12. Effect of the gamma radiation on the chemical, rheological, baker and microbiological properties in wheat flour; Efecto de la radiacion gama sobre las propiedades quimicas, reologicas, panaderas y microbiologicas en harina de trigo

    Energy Technology Data Exchange (ETDEWEB)

    Agundez A, Z; Fernandez R, M V [Departamento de Ciencias Quimico Biologicas, Universidad de Sonora, Hermosillo (Mexico); Arce C, M E; Cruz Z, E [Instituto de Ciencias Nucleares, UNAM, 04510 Mexico D.F. (Mexico); Chernov, V; Barboza F, M [Departamento de Investigacion en Fisica, Universidad de Sonora, Hermosillo (Mexico)

    2002-07-01

    The gamma radiation has been used in several places of the World as a sterilization method, preservation and pasteurization of foodstuffs, effect which is achieved due to diminishing or elimination of the microorganisms, reaching every time more acceptance, moreover eliminates the uses of toxic and carcinogenic substances, of general use, but at the present, being in the process of being totally prohibited, due to the higher risk in the human health. In this work the related results with the effects of the gamma radiation are presented, coming from a {sup 60} Co source, in commercial wheat flour exposed to a dose of 1.0 KGy. The used dose is that allowed according to the NOM-033-SSA1-1993 standard. It was determined that the chemical characteristics of humidity, protein and ashes were not affected by radiation. The rheological properties neither suffer severe effects as consequence of radiation; the pharynographic and alveographic parameters were lightly affected by the treatment. Significant changes were detected in the percentage of water absorption and in the tolerance index to mixing. However a diminish of 10% in the development time and an increase of 13% in the stability was observed, for the irradiated samples respect to the those samples not irradiated. In relation to the alveograph parameters it was only detected a diminish of 7% in the force parameter (w) without changes in the tenacity/blowing up index ratio (P/L). The fall number diminish 11% indicating a small diminution in viscosity. The bakering properties do not turn out modified by the irradiation treatment finding a specific weight of 4.6 and 4.5 (cm{sup 3}/g) for the control and irradiated samples, respectively. In the mesophyll analysis it was found a diminish of 96% from the original charge in control samples, observing a diminution of 74 and 25% in yeasts and mushrooms respectively. Microbiologically it was determined absence of total coliforms bacteria and faecal coliforms in the control

  13. Radiations and regulation (of ionizing radiations from nuclear sources); Radiaciones y regulacion (de las radiaciones ionizantes de origen nuclear)

    Energy Technology Data Exchange (ETDEWEB)

    Ferreri, Juan C., E-mail: jcferreri@gmail.com [ARN Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); CONICET Consejo Nacional de Investigaciones Cientificas y Tecnicas, Buenos Aires (Argentina)

    2009-07-01

    Some contextual aspects of the regulatory action regarding the use of ionizing radiations (X-rays excluded) are made explicit. Some sociological aspects establishing the framework for the regulatory action, a tentative definition of what a regulator is and the role of precaution on his acting are discussed. Furthermore, a unified definition of human nature and physical nature (i.e. nature) is introduced, aimed at allowing its protection regarding ionizing radiation and, at the same time, the ethical framework for the application of radiation protection actions is defined. (author) [Spanish] Se explicitan algunos aspectos de contexto del accionar regulatorio asociado con el uso de las Radiaciones Ionizantes de origen nuclear (RI). Se muestran cuales son las consideraciones de tipo sociologico que permiten enmarcar la actividad de un regulador, se intenta una definicion del mismo y se discute cual es el rol de la precaucion en su accionar. Se introduce ademas una definicion abarcadora en la consideracion de la naturaleza humana y la naturaleza fisica (es decir la naturaleza) al efecto de su proteccion con respecto a las RI, al tiempo que se define el marco etico adecuado para su consideracion. (autor)

  14. New method of preparation of CaSO{sub 4}: Dy for ionizing radiation dosimetry; Nuevo metodo de preparacion del CaSO{sub 4}: Dy para dosimetria de radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Rivera M, T.; Alarcon F, G.; Guzman M, J. [CICATA-IPN, 11500 Mexico D.F. (Mexico); Azorin N, J.; Sosa F, R. [UAM-I, 09340 Mexico D.F. (Mexico); Serrano F, A.K. [Hospital Juarez General de Mexico, 07760 Mexico D.F. (Mexico)]. e-mail: holand_jeos@hotmail.com

    2008-07-01

    In this work some results of the characterization of solid state materials exposed at a gamma radiation beam coming from a {sup 60} Co bomb for medical use are presented. These thermoluminescent dosemeters are prepared and proposed for the ionizing radiations dosimetry using the thermoluminescence method. The passive dosemeters of CaSO{sub 4}: Dy are developed in the polycrystalline powder form being used a new synthesis route by means of the precipitation method. To determine the sensibility of the pellets of CaSO{sub 4}: Dy before gamma radiation, these were exposed before a gamma radiation beam coming from a {sup 60} Co bomb. The morphological and structural characteristics were also studied and present two in this work. (Author)

  15. The Use of Ionizing Radiation as a Means of Processing Foodstuffs for Storage: Present Status and Future Prospects; Utilisation des Rayonnements Ionisants pour la Conservation de Produits Alimentaires: Situation Actuelle et Perspectives; Sostoyanie i perspektivy primeneniya ioniziruyushchikh izluchenij dlya obrabotki pishchevykh produktov v svyazi s ikh khraneniem; Estado Actual y Perspectivas del Empleo de las Radiaciones Ionizantes para la Conservacion de los Productos Alimenticios

    Energy Technology Data Exchange (ETDEWEB)

    Rogachev, V. I. [Vsesojuznyj Nauchno-Issledovatel' skij Institut Konservnoj i Ovoshesushil' noj Promyshlennosti Moskva, SSSR (Russian Federation)

    1966-11-15

    produits figurent la viande et les preparations a base de viande (produits crus ou semi-prepares, charcuterie), volaille, divers fruits et legumes, pommes de terre, cereales, produits deshydrates (fruits et legumes seches, produits alimentaires secs concentres). Outre les methodes d'irradiation qui ont deja ete mises au point pour empecher la germination des pommes de terre et des oignons lors du stockage, il sera possible de recourir prochainement a l'irradiation pour la desinsection industrielle de produits alimentaires. (author) [Spanish] En la Union Sovietica se estudia el empleo de las radiaciones ionizantes para tratar los productos alimenticios con las siguientes finalidades: a) impedir la germinacion de las patatas y las cebollas: b) desinsectacion de los productos alimenticios; c) eliminacion de la actividad biologica de los microorganismos con miras a la esterilizacion o a la eliminacion parcial de la actividad biologica de la microflora para prolongar el tiempo de conservacion de diversos productos alimenticios; d) modificacion del tiempo de maduracion de los frutos y verduras despues de su recoleccion. En la memoria se expone el estado de los trabajos efectuados en la Union Sovietica en los ultimos anos y se examinan las perspectivas del empleo de las radiaciones para un cierto numero de productos. Entre estos figuran la carne y sus derivados (productos crudos y semipreparados, charcuteria), aves de corral, diversas frutas y verduras, patatas, cereales, productos deshidratados (frutas y verduras secas, productos alimenticios secos concentrados). Ademas de las tecnicas de irradiacion ya elaboradas para impedir la germinacion de las patatas y las cebollas durante su almacenamiento, podra recurrirse proximamente a la irradiacion para la desinsectacion industrial de productos alimenticios. (author) [Russian] Izuchenie primenenija ionizirujushhih izluchenij dlja obrabotki pishhevyh produktov provoditsja v SSSR v sledujushhih napravlenijah: a) predotvrashhenie

  16. Batteryless {gamma}-Ray Dosimeter; Dosimetre de rayons {gamma}, sans batteries; {gamma}-dozimetr bez batarei; Dosimetro a rayos {gamma} sin bateria

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Bernhard [National Institute of Technology, Rio de Janeiro (Brazil)

    1960-06-15

    The Compton current produced by X-rays and {gamma}-rays in the 0.3 to 3 MeV range is proportional to the radiant energy flux. Therefore the intensity of the current can be used as a measure of radiation dose. The present paper describes a radiation receiver and electrical measuring system suitable for Compton current measurements and results obtained with this device under irradiation from a 2000 curie Co{sup 60} source. (author) [French] Le courant de Compton produit par des rayons X et {gamma} dans le domaine d'energies compris entre 0,3 et 3 MeV est proportionnel au flux d'energie rayonnante. C'est pourquoi l'intensite du courant peut servir de mesure de la dose de rayonnements. Le memoire decrit un ensemble, appareil recepteur de rayonnements et appareil de mesure electrique, permettant de mesurer le courant de Compton et il expose les resultats obtenus, au moyen de ce dispositif, sous irradiation par une source de Co{sup 60} de 2000 curies. (author) [Spanish] La corriente de Compton producida por rayos X y rayos {gamma} de energia comprendida entre 0,3 y 3 MeV es proporcional al flujo de energia radiante. Por consiguiente, la intensidad de la corriente puede servir para medir la dosis de radiacion. En este trabajo se describen un receptor de radiaciones y un sistema de medicion electrica apropiados para determinar la intensidad de la corriente de Compton, asi como los resultados obtenidos mediante este dis- positivo cuando se irradia con una fuente de Co{sup 60} de 2000 curies. (author) [Russian] Komptonovskij potok, obrazuemyj rentgenovskim i luchami i {gamma}-luchami v predelakh ot 0,3 do 3 mehv, proportsionale n potoku luchistoj ehnergii. Poehtomu intensivnost' potoka mozhet byt' ispol'zovana dlya izmereniya dozy radiatsii. V nastoyashchem dokumente opisyvayutsya radiatsionny j priemnik i ehlektricheskaya izmeritel'naya sistema, prigodnye dlya izmerenij s pomoshch'yu komptonovskog o potoka, i rezul'taty, poluchennye s pomoshch'yu ehtogo ustrojstva v khode

  17. Comparative study of series of solar radiation; Estudio comparativo de series de radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Adaro, Agustin; Cesari, Daniela; Lema, Alba; Galimberti, Pablo; Barral, Jorge [Universidad Nacional de Rio Cuarto, (Argentina)

    2000-07-01

    la energia solar se debera contar con la mas adecuada informacion sobre los niveles de radiacion. Siendo esta fuente de energia dependiente de las fluctuaciones atmosfericas y meteorologicas, es que se requiere contar con la mas certera informacion respecto a la cantidad y variabilidad de la energia solar disponible. Un camino es el tratamiento estadistico de los datos ya disponibles, tanto de radiacion solar como de horas de sol. Este enfoque genera mucha expectativa por la mayor cantidad de informacion respecto a las horas de sol existente. Esta mayor informacion de horas de sol se debe a que las mediciones se realizan con instrumentos llamados heliografos con un nivel de complejidad y costo mucho menor que los instrumentos de medicion de radiacion. Entre los heliografos el mas utilizado es el de Campbell - Stokes, y es el que se a instalado en la mayoria de las estaciones meteorologicas de Argentina y el Mundo, por lo que la informacion de horas de sol es la que mas abunda. El presente trabajo tiene por objetivo encontrar una interrelacion entre las series medidas de horas de sol e irradiacion. El estudio se realiza utilizando modelos de series temporales y el modelo de Angstrom-Page. Se realiza ademas un estudio de la generacion de secuencias de radiacion utilizando el concepto de las Cadenas de Markov. Se analizan las series para Rio cuarto determinandose la funcion de transferencia entre ambas series, y se obtienen los valores de radiacion solar global para localidades de la misma region. Se encuentran los coeficientes de la Ecuacion de Anstrom-Page para Rio Cuarto. Se encuentra los valores medios mensuales por estos dos metodos y se comparan resultados.

  18. Trastornos hematopoyéticos en trabajadores expuestos a radiaciones ionizantes

    Directory of Open Access Journals (Sweden)

    Agustín Méndez Arias

    2014-03-01

    Full Text Available Los estándares de protección radiológica, se derivan de estimaciones principalmente de estudios epidemiológicos de los supervivientes japoneses de los bombardeos atómicos de Hiroshima y Nagasaki. El reciente accidente nuclear en Fukushima nos muestra que no estamos seguros y despierta el interés de conocer los efectos biológicos de las radiaciones ionizantes a dosis bajas por exposición laboral, mostrando la evidencia epidemiológica, relacionando las dosis y el tiempo de exposición, edad riesgo y tiempo de aparición de trastornos hematopoyéticos. La búsqueda bibliográfica se realizó mediante la selección de los términos MeSH y DeCS para buscar en las diferentes bases de datos. 82 estudios recuperados, más 14 estudios vía búsqueda manual, tras aplicarles los criterios de inclusión y exclusión se seleccionaron para revisión a texto completo 11 estudios: 4 cohorte y 7 casos y controles. En nuestra revisión hemos encontrado asociación para el desarrollo de Leucemia, P=0.03 con dosis <10 mSv de por vida, Mieloma Múltiple (MM P=0.037, Leucemia Linfoide Crónica ERR: 4.09 Gy 95% CI:<0-14.41. Encontramos que existe asociación significativa entre exposición laboral a radiaciones ionizantes a bajas dosis y el desarrollo de Leucemia y Mieloma Múltiple. Se encontró evidencia de riesgo aumentado de padecer leucemia (excluyendo LLC con tiempo de exposición mayor de 10 años y con dosis promedio de exposición <10 mSv. Existe evidencia en relación a la aparición de trastornos hematopoyéticos radioinducidos en el rango de 55-65 años coincidiendo con los últimos diez años de vida laboral. El hallazgo de una sugerente relación entre LLC y la exposición laboral a bajas dosis de radiaciones ionizantes deja la puerta abierta para futuras investigaciones.

  19. Thin films deposited by laser ablation for the measurement of the ionizing and non-ionizing radiation; Peliculas delgadas depositadas por ablacion laser para la medicion de radiacion ionizante y no ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Villarreal B, J.E.; Escobar A, L.; Camps, E.; Romero, S.; Gonzalez, P.; Salinas, B. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    2001-07-01

    In this work the obtained results to synthesize thin films of amorphous carbon with incorporated nitrogen and hydrogen are presented, as well as thin films of aluminium oxide using the laser ablation technique. The thin films were exposed to ionizing radiation (gamma rays of a {sup 60} Co source, beta radiation of a {sup 90} Sr source) and a non-ionizing radiation (UV radiation). The obtained results show that it is possible to obtain materials in thin film form with thickness of hundreds of nanometers, which present thermoluminescent response when being irradiated with ionizing radiation and non-ionizing radiation. (Author)

  20. Digital pulse shape discrimination between fast neutrons and gamma rays with para-terphenyl scintillator

    Science.gov (United States)

    Chepurnov, A. S.; Kirsanov, M. A.; Klenin, A. A.; Klimanov, S. G.; Kubankin, A. S.

    2017-12-01

    In the presented work, we investigated several digital methods of a discrimination signals from fast neutrons and gamma quanta. The experimental setup consists of a Pu-Be neutron source, a scintillation detector with an organic para-terphenyl monocrystal, and a digitizer (CAEN DT5730, 500 MS/s). Mixed waveform sequences were stored and then separated by pulse shape. Four methods were used for signals separation. Comparison of the traditional and the new methods of Figure of Merit (FOM) calculation is given. FOM = 1.5 was obtained in our setup for the minimum threshold value. A scintillation detector with a para-terphenyl crystal was used to measure neutron yield in the neutron generator with carbon nanotubes.

  1. Development of multichannel system for nuclear radiation spectrometry based on an embedded control and acquisition device Myrio-1900; Desarrollo de sistema multicanal para espectrometria de radiacion nuclear basado en un dispositivo embebido de control y adquisicion MyRIO-1900

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez D, S.

    2016-07-01

    This work describes the design a multichannel analyzer system 4096 channels (Mca) for gamma radiation spectrometry. The multichannel analyzer has as its main component an embedded company National Instruments model NI (Myrio-1900) module, which is integrated by a step of converting analog to digital signals (A / D) and digital-to-analog (D / A) a programmable gate array, and a processor real time (Rt). Through this module the pulses generated by the detector to be processed and subsequently forming the multichannel analyzer are acquired. In addition, a graphical user interface designed to make more use friendly system from a personal computer (Pc), embedded programming module and the user interface was done with the LabVIEW programming environment. tests with different sources of radiation ({sup 60}Co, {sup 226}Ra, {sup 137}Cs) and semiconductor detectors (Ge) and scintillation (Na) were made. Getting results satisfactory. (Author)

  2. Automatic Sample Changing System for Gamma-Ray Spectrometry; Changeur Automatique d'Echantillons Pourla Spectrometrie Gamma; Avtomaticheskaya sistema dlya smeny obraztsov pri gamma-spektrometrii; Cambiador Automatico de Muestras para Espectroscopia Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Lamson, K. C.; Sesko, W. J.; Nicholson, G. C. [Northeastern Radiological Health Laboratory, Winchester, MA (United States)

    1965-10-15

    intensement utilise pendant cette periode et s'est revele tout a fait satisfaisant. Son prix de revient, main-d'oeuvre comprise, est inferieur a 2000 dollars. (author) [Spanish] La deteccion en medios biologicos de radionuclidos emisores gamma de actividad poco superior a la ambiente requiere el empleo de un sistema de recuento muy sensible. Ademas, para lograr datos suficientemente precisos es necesario que el tiempo de recuento sea relativamente largo, a saber, de una a varias horas. Para utilizar con la mayor eficacia posible el equipo de recuento de espectrometria gamma de baja actividad de fondo, que es sumamente costoso, conviene hacerlo funcionar en forma continua durante 24 h al dfa. Para ello se requiere personal que lo atienda constantemente o un sistema de recuento enteramente automatico incluso para el cambio de muestras y el registro de los datos. En esta memoria se describe el sistema automatizado de recuento por espectroscopia gamma disenado, construido y utilizado en el Northeastern Radiological Health Laboratory de Winchester, Massachusetts. El cambiador de muestras funciona en conjuncion con un blindaje de acero que no necesita ser especial; cualquiera de los comerciales, si esta provisto de una puerta frontal, puede ser adaptado al cambiador. Dicho cambiador puede adaptarse a diversos tipos de muestras, incluidas las biologicas y medicas. Consta de una bandeja giratoria con capacidad para 16 muestras; un sistema localizador para las muestras; un brazo mecanico, con electroiman, para introducir o retirar las muestras desde el exterior, y una palanca para abrir y cerrar la puerta blindada. El cambiador se ha integrado completamente con un analizador multicanal provisto de dispositivos de seguridad que interrumpen el ciclo cuando se produce una averfa en cualquier punto. Despues de un periodo de recuento predeterminado, los datos pasan a una calculadora IBM 1620 transcritos en cinta de papel perforada. El primer modelo de cambiador de muestras, para el cual se

  3. Oncogenes, radiation and cancer; Oncogenes, radiacion y cancer

    Energy Technology Data Exchange (ETDEWEB)

    Michelin, S C

    1999-12-31

    The discovery of the oncogenic virus and the analysis of its nucleic acid, together with the development of new biochemical technology have permitted the partial knowledge of the molecular mechanisms responsible for the cellular neoplastic transformation. This work, besides describing the discovery of the first oncogenic virus and the experiments to demonstrate the existence of the oncogenes, summarizes its activation mechanisms and its intervention in cellular metabolisms. Ionizing radiation is among the external agents that induce the neoplastic process. Its participation in the genesis of this process and the contribution of oncogenes to the cellular radioresistance are among the topics, which are referred to another topic that makes reference. At the same time as the advancement of theoretical knowledge, lines of investigation for the application of the new concepts in diagnosis, prognosis and therapeutical treatment, were developed. An example of this, is the study of the participation of the oncogen c-erbB-2 in human breast cancer and its implications on the anti tumoral therapy. (author) 87 refs., 7 figs., 3 tabs. [Espanol] El descubrimiento de los virus oncogenicos y el analisis de su acido nucleico, junto con el desarrollo de nuevas tecnicas bioquimicas, ha permitido conocer parcialmente los mecanismos moleculares responsables de la transformacion de una celula normal en neoplasica. En este trabajo, ademas de describir el descubrimiento de los primeros virus oncogenicos y las experiencias para demostrar la existencia de los oncogenes, se resumen sus mecanismos de activacion y su intervencion en el metabolismo celular. Entre los agentes expernos que inducen un proceso oncogenico, se encuentran las radiaciones ionizantes. Su participacion en la genesis de este proceso y la contribucion de los oncogenes a la radioresistencia de las celulas tumorales, es otro de los temas a que se hace referencia. Paralelamente al avance del conocimiento teorico, se

  4. Automation of the monitoring in real time of the absorbed dose rate in air due to the environmental gamma radiation in Cuba; Automatizacion del monitoreo en tiempo real de la tasa de dosis absorbida en aire debido a la radiacion gamma ambiental en Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Dominguez L, O; Capote F, E; Carrazana G, J A; Manzano de Armas, J F; Alonso A, D; Prendes A, M; Zerquera, J T; Caveda R, C A [CPHR, Calle 20, No. 4113 e/41 y 47, Playa, La Habana, 11300, A.P. 6195 C.P. 10600 (Cuba); Kalberg, O [Swedish Radiation Protection Institute (SSI) (Sweden); Fabelo B, O; Montalvan E, A [CIAC, Camaguey (Cuba); Cartas A, H [CEAC, Cienfuegos (Cuba); Leyva F, J C [CISAT (Cuba)

    2006-07-01

    The Center of Protection and Hygiene of the Radiations (CPHR) like center rector of the National Net of Environmental Radiological Surveillance (RNVRA), it has strengthened their detection capacity and of answer before a situation of radiological emergency. The measurements of the absorbed dose rate in air due to the environmental gamma radiation in the main stations of the Net are obtained in real time and the CPHR receives the data coming from these posts at one time relatively short. To improve the operability of the RNVRA it was necessary to complete the facilities of existent monitoring using 4 automatic measurement stations with probes of gamma detection, implementing in this way a measurement system on real time. On the other hand the software were developed: GenironProbeFech, to obtain the data of the probes, DataMail for the shipment of the same ones by electronic mail and GammaRed that receives and processes the data in the rector center. (Author)

  5. Effect of chlorophyllin on induction of exchanges in sister chromatids by gamma irradiation in mice spermatogonia in vivo; Efecto de la clorofilina sobre la induccion de intercambios en las cromatidas hermanas (ICH) por radiacion gamma en espermatogonias de raton In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M T

    1994-12-31

    Mouse were exposed to different doses of gamma radiation and the effect on Sister Chromatid Exchange (SCE) frequency in spermatogonias was evaluated. The effect was analyzed before and after Bromodeoxyuridine (BrdU) incorporation to determine the interference of such agent with the cellular response induced by radiation. The capacity of chlorophyllin (sodium and Copper salt derivative from chlorophyll) to reduce SCE induction by radiation in normal and BrdU radio sensitized spermatogonia was also determined. The results indicate that there was a significant increase in SCE frequency by gamma radiation exposure in these cells, such effect was higher irradiating after BrdU incorporation than before. This fact confirms previous observations that BrdU sensitizes some cells to SCE induction. With regard to the chlorophyllin effect, it was determined that this salt acts as a radioprotector reducing gamma-rays induced SCE before or after BrdU incorporation Total protection was obtained with 200 {mu}g of chlorophyllin per g of body weight in both protocols. Under the experimental conditions this study there was no evidence of genotoxicity induced by chlorophyllin itself. The results suggest that this agent may act as a radioprotector by scavenging free radicals produced by gamma-radiation which cause DNA lesions that are involved in SCE formation. (Author).

  6. Relationship among the repair and genetic recombination mechanisms. II. Effect of gamma radiation on the lambda recombination in E. coli AB1157 and AB1886; Relacion entre los mecanismos de reparacion y la recombinacion genetica. II. efecto de la radiacion gamma sobre la recombinacion de lambda en E. Coli AB1157 y AB1886

    Energy Technology Data Exchange (ETDEWEB)

    Alcantara D, D [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1988-08-15

    The objective of the present work is to determine if the radiation gamma that is a good inductor of the answer SOS of Escherichia Coli but that it produces alterations in the DNA very different to those taken place by the light UV, it is able to stimulate the viral recombination. (Author)

  7. Oxidation of ortho- and para-aminobenzoic acid. A pulse radiolysis- and gamma radiolysis study

    International Nuclear Information System (INIS)

    Solar, Sonja; Getoff, Nikola; Zona, Robert; Solar, Wolfgang

    2011-01-01

    The oxidation of anthranilic acid (ortho-aminobenzoic acid, ANA) and para-aminobenzoic acid (PABA) by · OH, N 3 · and O ·- in basic solution was studied by pulse radiolysis. The kinetic and spectroscopic characteristics of the intermediate transients were determined. For ANA the site attack of the OH radicals was established to be ∼50% on the -NH 2 moiety and ∼50% on the aromatic ring with an overall rate constant k( · OH+ANA)=(5.5x10 9 ) dm 3 mol -1 s -1 . The rate constant of PABA was k( · OH+PABA)=8x10 9 dm 3 mol -1 s -1 . The OH-adducts of both compounds showed a first order decay of 0.8x10 5 and 1.2x10 5 s -1 , respectively, whereby the corresponding anilino-radicals were formed. The rate constant of ANA with solvated electrons was k(e - aq +ANA)=2.9x10 9 dm 3 mol -1 s -1 . The radiation induced decomposition of both substrates was studied by gamma radiolysis as a function of the absorbed dose. They exhibited a distinct radiation resistance, the initial degradation yields were ∼0.16 μmol J -1 , i.e. only 28% of the · OH radicals contributed to their decomposition. The hydroxylation process was of minor importance, the yield of hydroxylated aminobenzoic acids was≤0.01 μmol J -1 .

  8. Isolation of a bacteria of the Bacillus genus as indicator in the disinfection of residual waters by means of the ionizing radiation (e{sup -} , {gamma}); Aislamiento de una bacteria del genero Bacillus como indicador en la desinfeccion de aguas residuales mediante la radiacion ionizante (e{sup -} , {gamma})

    Energy Technology Data Exchange (ETDEWEB)

    Mata J, M

    2003-07-01

    The pollutants of the water can be chemical, physical and biological. Among those biological we find to the microorganisms: bacterias, virus and protozoa. These cause important infections in many countries, mainly of Latin America. With the advance of the technology and the quick demographic growth, the biological pollution of the water has already become an important topic since it would damage the public health and it causes that their disinfection has greater attention. In the treatment of residual waters three basic treatments exist the one primary, secondary and tertiary; in this last we find the disinfection, which can be taken to end by chemical and physical methods. For this work of investigation it was used the ionizing radiation, because it is an innovative technology that it eliminates microorganisms in residual waters. The investigation consisted on treating, samples of residual water after the biological treatment of the plant RECICLAGUA with ionizing radiation (electrons and gammas), for the case of electrons it was used the dose of 0.5 kGy and for gamma the dose, of 5 kGy, later the survivor bacteria was isolated to these doses in both cases and they were carried out the tests of identification. In accordance with the obtained results can say that it is about a B. subtilis. The isolated B.subtilis was presented as a pollutant of the flora of the residual water, having a greater survival to the dose of 0.5 and 5 kGy with electrons and gammas, respectively that other present polluting microorganisms in the samples of residual water. For it fits signalize that this microorganism shows characteristics as it easy isolation and identification, the presence with pathogen microorganisms and a greater survival when being irradiated, therefore it can use as indicator in the disinfection of residual waters through ionizing radiation (electrons and gammas). (Author)

  9. Effect of gamma radiation of {sup 60}Co in the variability of chinese bean [Vigna unguiculata (l.) Walpers] en R{sub 4}M{sub 4}; Efecto de la radiacion gamma de {sup 60}Co en la variabilidad de frijol chino [Vigna unguiculata (l.) Walpers] en R{sub 4}M{sub 4}

    Energy Technology Data Exchange (ETDEWEB)

    Salmeron E, J.; Bueno J, J.E.; Valencia E, F. [CSAEGro, Iguala, Guerrero, Tel and Fax 01 733 (33) 24328 (Mexico); Cervantes S, T. [IREGEP (Mexico); Cruz T, E. De la [ININ, Departamento de Biologia, 52750 La Marquesa, Estado de Mexico (Mexico)]. e-mail: csaegro@prodigy.net.mx

    2007-07-01

    Selection of plants of Chinese bean coming from seed irradiated with gammas of {sup 60}Co in the generation R{sub 4}M{sub 4} (fourth recurrent irradiation, fourth segregate generation) were carried out, taking as selection approaches the plant architecture, the numbers of sheaths for plant, sheath longitude, position of the sheaths, grain size and resistance to plagues and illnesses. 17 lines were selected for grain and 3 lines with fodder characteristics of black grain color were also obtained. (Author)

  10. An Assessment of those Metabolites Considered to be of Value in the Diagnosis of Exposure to Radiation; Evaluation des Metabolites Consideres Comme Utiles dans le Diagnostic des Expositions aux Rayonnements; 041e 0426 0414 ; Evaluacion de los Metabolitos Considerados Utiles para Diagnosticar la Exposicion a las Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.; Bates, T. H. [United Kingdom Atomic Energy Authority, Chapelcross, Annan, Scotland (United Kingdom)

    1965-06-15

    a suivi de pres - du point de vue quantitatif - l'excretion urinaire des substances suivantes: creatinine, creatine, {beta}-nitramine (total), acide {beta}-amino isobutyrique, acide pyrrole-2-carboxylique, acide hydroxy-5-indolylacetique et indoxyle-sulfate. Bien qu'aucun des sujets n'ait subi une irradiation de l'organisme entier, on constate que des modifications de la fonction metabolique resultant de radiolesions peuvent influer sur l'excretion urinaire. Les auteurs examinent les raisons biochimiques et l'interpretation de ces formes d'excretion pour la partie de l'organisme qui a ete irradiee; cependant, au stade actuel de l'enquete, ils arrivent a la conclusion qu'une evaluation quantitative des lesions biologiques n'est pas possible. Neanmoins, ces essais peuvent faciliter au clinicien le choix de la therapie a appliquer. Des essais preliminaires sur les changements observes dans certains metabolites du plasma, chez des rats exposes a une seule dose sous-letale de rayons X, meritent d'etre extrapoles en vue de leur application a des etudes sur l'homme. On a mesure les concentrations dans le plasma des matieres ci-apres: hydroxy- 5-tryptamine, acide urique, transaminases glutamo-oxalacetique et glutamo-pyruvique du serum, 'fractions globuliniques de la proteine, phosphokinase de creatine, aminopeptidase de leucine, aminopeptidase de lysyle, callicreine, callidine, zinc et manganese. Des changements qualitatifs pourtant assez importants ont ete observes, apres irradiation, dans les teneurs du plasma en acide urique, en aminopeptidase de leucine, en aminopeptidase de lysyle, en zinc et en manganese. Les auteurs examinent la portee de ces donnees. Dans ces etudes, ils ont surtout utilize des methodes simples et rapides. (author) [Spanish] Se han examinado algunos metabolitos excretados por via urinaria por seres humanos expuestos a radiaciones X y {gamma} con fines terapeuticos. Dichos pacientes habian recibido dosis de hasta 5000 r durante un periodo comprendido

  11. Simplified Procedures for Obtaining Clearances of Foods Preserved by Ionizing Energy; Procedures Simplifiees pour Obtenir l'Autorisation de Produire des Denrees Alimentaires Conservees par les Rayonnements Ionisants; Uproshennaya protsedura polucheniya razreshenij na prodazhu obluchennk pishchevykh produktov; Simplificacion de los Procedimientos para la Obtencion de Autorizaciones de Venta de Alimentos Conservados Mediante Radiaciones Ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Josephson, E. S. [United States Army Natick Laboratories, Natick, MA (United States)

    1966-11-15

    pommes de terre a chair blanche, la comestibilite de ces denrees etant tout a fait satisfaisante. Aux Etats-Unis, pour developper la production de ces denrees dans des proportions suffisantes pour alimenter le marche, il est necessaire d'obtenir l'autorisation du Service de controle des produits alimentaires et pharmaceutiques et, pour les viandes de mammiferes et de volatiles, celle du Departement de l'agriculture. Ces institutions ont approuve la mise sur le marche de lard, de ble et derives et de pommes de terre a chair blanche, apres reception et examen de demandes contenant tous les renseignements pertinents, notamment la description du procede d'irradiation et de conditionnement a faire accepter, la source de rayonnements proposee, la dose, les methodes de dosimetrie, les donnees relatives a la comestibilite et a la valeur nutritive, la preuve positive de l'innocuite microbiologique, l'absence de radioactivite induite mesurable, le certificat d'acceptation d'un groupe de degustateurs et, s'il y a lieu, les donnees relatives a l'emmagasinage et a l'expedition. Le rassemblement des donnees necessaires aux demandes d'autorisation s'est revele a l'usage long et couteux. Pour remedier a cet inconvenient, on etudie actuellement les moyens de simplifier et d'accelerer le rassemblement des donnees et la redaction des demandes. L'auteur presente des recommandations touchant certaines des methodes qui permettraient d'arriver a ce resultat. (author) [Spanish] Despues de trece anos de investigaciones intensivas con aplicacion de elevadas dosis de radiaciones ionizantes se ha logrado prolongar considerablemente en laboratorio el perfodo de conservacion de productos tales como el tocino, el jamon, la carne de cerdo, la carne de vaca, los pollos y los mariscos, sin que pierdan su comestibilidad. Aplicando dosis inferiores al Mrad puede prolongarse el perfodo de conservacion del pescado, del trigo y sus derivados, de las naranjas y de las patatas blancas en condiciones de

  12. Effect of gamma radiation on photosynthetic metabolism of Chlorella pyrenoidosa studied by 14{sup C}O{sub 2} assimilation; Estudio del efecto de la radiacion gamma sobre el metabolismo fotosintetico de Chlorella pyrenoidosa mediante asimilacion de 14{sup C}O{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C; Fernandez, J

    1983-07-01

    The effect of five dose of gamma radiation (10, 100, 500, 1000 and 5000 Gy) on photosynthetic activity and metabolism of the primary products of photosynthesis has been studied, on Chlorella pyrenoidoBa cultures, by 14{sup C}O{sub 2} assimilation. The photosynthetic assimilation rate is remarkably depressed after irradiation at 500, 1000 and 5000 Gy dose, which also produce a significant change in radioactivity distribution pattern of primary compounds from photosynthesis. No significant effects have been observed on photosynthetic metabolism after irradiation at 10 and 100 Gy. (Author) 19 refs.

  13. Density determination in Pino Radiata (D.Don) samples using 59.5 keV gamma radiation attenuation; Determinacion de densidad en muestras de Pino Radiata (D. Don) mediante atenuacion de radiacion gamma de 59.5 KeV

    Energy Technology Data Exchange (ETDEWEB)

    Dinator, Maria I; Morales, Jose R; Aliaga, Nelson [Chile Univ., Santiago (Chile). Dept. de Fisica; Karsulovic, Jose T; Sanchez, Jaime; Leon, Adolfo [Chile Univ., Santiago (Chile). Dept. de Tecnologia de la Madera

    1997-12-31

    A non destructive method to determine wood samples density is presented. The photon mass attenuation coefficient in samples of Pino radiata (D.Don) was measured at 59.5 keV with a radioactive source of Am-241. The value of 0.192 {+-} 0.002 cm{sup 2}/g was obtained with a gamma spectroscopy system and later used on the determination of the mass density in sixteen samples of the same species. Comparison of these results with those of gravimetric method through a linear regression showed a slope of 1.001 and a correlation factor of 0.94. (author). 3 refs., 4 figs.

  14. {beta} -carotene effect the induction of the sister chromatid exchanges (ICH) by gamma radiation in mouse radiosensibilized osseous marrow cells In vivo; Efecto del {beta}- caroteno la induccion de intercambios en las cromatidas hermanas (ICH) por radiacion gamma en celulas radiosensibilizadas de la medula osea de raton In vivo

    Energy Technology Data Exchange (ETDEWEB)

    Morales R, P.; Cruz V, V.L. [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico). Dept. de Biologia

    1997-07-01

    The effect of {beta}- carotene over the ICH radioinduction in radiosensibilized with BrdU osseous marrow cells of mouse was determined In vivo. The treatment with 50 {mu}g {beta} carotene per se induces a significant increment in the ICH frequency and the pre or post-treatment with the same dose causes an additive effect in the ICH frequency produced by 0.62 Gy of gamma radiation. This implies that {beta}- carotene does not have radioprotective activity, under conditions which was developed this experiment. (Author)

  15. Effects of the radiation gamma on the activity and selectivity of the Al{sub 2} O{sub 3} in the retention of uranium and fission products; Efectos de la radiacion gamma sobre la actividad y selectividad del Al{sub 2} O{sub 3} en la retencion de uranio y productos de fision

    Energy Technology Data Exchange (ETDEWEB)

    Duran B, J M

    1997-12-31

    The study that here comes constitute a contribution for the treatment of based on waste the properties of retention of the inorganic oxides. The effect induced of the radiation has been determined gamma of the {sup 60} Co in the Al{sub 2} O{sub 3} and their influence in their capacity of retention of uranium and products of fission of watery solutions strongly alkaline. In order to obtain useful information it made the superficial characterizations, structural, crystalline and of retention by means of the techniques of superficial adsorption, spectroscopy infrared, rays-X diffraction, liquid twinkling and {gamma}- spectrometry. The obtained results show that the treatment of the Al{sub 2} O{sub 3} this associated with slight changes in their structural characteristics and superficialities concluding that the molecular water present in the crystalline net of the oxide was not displaced radiolytic for effect, but rather, this spread in the volume of the oxide, blocking the change in the contribution to crystalline of the oxide. (Author).

  16. Estimate potential evaporation and solar radiation in the Yaqui valley, Sonora, Mexico, using data from satellite; Estimacion de evaporacion y radiacion solar en el valle del Yaqui, Sonora, usando datos de satelite

    Energy Technology Data Exchange (ETDEWEB)

    J Watts, Christopher; Rodriguez, Julio Cesar [Instituto del Medio Ambiente y el Desarrollo sustentable del estado de Sonora (Mexico); Garatuza Payan, Jaime [Instituto Tecnologico de Sonora (Mexico); Henk de Bruin [Universidad Agricola de Wageningen (Netherlands); Stewart, John [Universidad de Southampton (United Kingdom)

    1999-12-01

    The data from tow automatic weather stations in the Yaqui valley were used to estimate potential evaporation using the Makkink formula, based on observed incoming solar radiation and climatological values of air temperature. The usefulness of this formula was assessed by comparison with the Penman-Monteith, Penman and Priestley-Taylor formula and measurements of net radiation. A methodology was presented for estimating incoming solar radiation using visible band data from the GOES satellite. Comparisons against ground-based measurements from two pyranometers installed in the Yaqui valley gave good results, particularly in months with low cloud cover. Images for August 1993 were used to produce a map of the spatial distribution of potential evaporation. [Spanish] Para calcular la evaporacion potencial en el valle del Yaqui, usando la formula de Makkink, se utilizaron datos de dos estaciones meteorologicas automaticas. La mencionada formula se basa en la radiacion solar incidente observada y en ciertos valores climatologicos de temperatura del aire. Se evaluo la utilidad de esta formula, comparandola con las de Penman-Monteith, Pennan y Priestley-Taylor, asi como con mediciones de radiacion neta. Se desarrollo una metodologia para estimar la radiacion solar incidente usando la banda visible del satelite GOES. Se hizo una comparacion con mediciones de dos piranometros instalados en el valla del Yaqui, obteniendose buenos resultados, principalmente en meses con poca nubosidad. Se utilizaron imagenes de agosto de 1993 para producir un mapa de la distribucion espacial de la evaporacion potencial.

  17. Effect of the crystallinity in the Tl signal induced by the gamma radiation in Al{sub 2}O{sub 3}: Eu obtained by the sol gel method; Efecto de la cristalinidad en la senal Tl inducida por la radiacion gamma en Al{sub 2}O{sub 3}: Eu obtenida por el metodo sol gel

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza A, D.; Gonzalez M, P.R. [ININ, Gerencia de Ciencias de Materiales. Carr. Mexico-Toluca Km. 36.5, 52045 Ocoyoacac (Mexico); Custodio, E. [Universidad Juarez Autonoma de Tabasco, DACB, Carr. Cunduacan-Jalpa, km. 1.5, 86680 Tabasco (Mexico); Rubio, E.; Rodriguez L, V. [Facultad de Ingenieria Quimica, BUAP. Av. San Claudio y 18 Sur Col. San Manuel. C. P. 72570.C.U. Puebla (Mexico)

    2004-07-01

    In this work the synthesis and characterization process of Al{sub 2}O{sub 3} and Al{sub 2}O{sub 3}: Eu by sol gel method is reported. A previous thermal treatment at 500 and 1000 C on the material powder type showed a notable influences on the thermoluminescent signal induced by the gamma radiation, such that the intensity thermoluminescent signal produced by samples with thermal treatment at 1000 C is much bigger that thermoluminescent signal produced by samples thermal treatment at 500 C. In order to explain this behavior, an analysis for X-ray diffraction and electron microscopy was also realized. The results show a notably influence of the crystalline array and the microstructure on the thermoluminescent behavior of the alumina. (Author)

  18. Effect of the gamma radiation and common antioxidants on some aspects of osteoblast differentiation during the formation of bone tissue in an in-vivo model; Efecto de la radiacion gamma y antioxidantes comunes sobre algunos aspectos de la diferenciacion de los osteoblastos durante la formacion de tejido oseo en un modelo in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Quinones O, M. G.

    2015-07-01

    Gamma radiation is the emission of energy through short electromagnetic waves to a higher level of frequency with respect to ultraviolet light. This type of energy in the medical application is used as a tool to kill cancer cells in humans, however, adverse damages to its exposure can produce secondary effects in the short and long term depending on the damage in cells and tissues nearby to the irradiation zone, the human body will present various injuries and conditions. In bone tissue, secondary effects that have been observed, is an alteration of the architecture and integrity of bone extracellular matrix of cortical and trabecular tissue, which causes loss of bone density. However, the reason that the bone tissue is affected is not clear, but is believed to be related to the formation of free radicals, which generate oxidative damage in biomolecules of the cells, damaging the tissue structure, organs and systems of the human body. The studies to identify the main reasons that will affect bone tissue as a result of radiotherapy have been carried out by models In-vitro and some In-vivo. In most studies in-vitro with cells with osteoblast phenotype, the results suggest alterations in proliferation and differentiation of these cells. However, the etiology and the role of these changes in disorders and bone injuries as adverse secondary effects of the radiotherapy are very poorly understood to date. In the present study an In-vivo model was used, that are ectopic bone plates which are developed by endochondral ossification, after having implanted demineralized bone particles at 16 days of development, at which time they are constituted by bone tissue. Ectopic bone plates were used with the aim of knowing as gamma radiation indirectly modifies to cellular level the osteoblast differentiation, cells that are involved in the formation and mineralization of bone extracellular matrix. One of the well known effects of gamma radiation is the generation of free radicals

  19. Observe gamma rays to find out how the universe works; Observar rayos gamma para saber como funciona El universo

    Energy Technology Data Exchange (ETDEWEB)

    Tapia, R.

    2015-07-01

    Each hemisphere of the Earth will host one of the two venues of the future network of telescopes Cherenkov (cta, Cherenkov telescope array) designed with the aim of covering all outer space and in stereo, a technique that allows us to reconstruct efficiently the properties of spatial events. Thanks to telescopes with which will be equipped with - greater sensitivity than the current - will be possible to study in detail one of the most powerful radiation of the Universe, gamma rays. Spain has been chosen to host the North Observatory on roque of the boys, on the island of Palma, facilities that will be form das by 20 telescopes. (Author)

  20. Evaluation of the oxidative stress modulation in Drosophila melanogaster strains deficient in endogenous antioxidants and with chronic exposure to casiopeina Cas II-gly and gamma radiation; Evaluacion de la modulacion del estres oxidante en cepas de Drosophila melanogaster deficientes en antioxidantes endogenos y con exposicion cronica a casiopeina CII-gly y radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Jimenez V, E. R.

    2013-07-01

    The casiopeinas are a family of coordination compounds with copper metallic center that have shown to have antineoplastic activity. The experimental evidences suggest that its action mechanism is through the generation of free radicals. The casiopeina (Cas II-gly) is believed to causes oxidative damage in the mitochondria, leading to the cellular death. The present study has the purpose to evaluate the antioxidant potential of the tetrapyrroles: cupro-sodica chlorophyllin (CSC), protoporphyrin-Ix (Pp-Ix) and the bilirubin (Bili) against the oxidant action of the Cas II-gly. The present study will also contribute in the characterization of the biological activity of the Cas II-gly. For this purpose is quantifies the effect of these compounds in the enzymes activity, superoxide dismutase (Sod) and catalase (Cat) in wild Drosophila melanogaster strains Canton-S and in the deficient in Sod and Cat. Two protocols were used, in the first male of 1-24 h of age were pre-treated with 0, 0.01, 0.1 and 1 m M of Cas II-gly and later on they were treated with radiation (15 Gy), and the second 69 m M of CSC, Pp-Ix or Bili, during 8 days and later they were treated with 0.1 m M of Cas II-gly during 24 h. The enzymatic activity was measured with the detection packages of enzymes Sod and Cat of Sigma. It was found that none of the three pigments increment the Sod activity but, if they diminished that of Cat (p≤0.007). The three concentrations of Cas II-gly did not increase the Sod activity significantly, only the concentration of 0.1 m M diminishes in 5.6 U the Cat activity (p <0.03) the same as the treatment with 15 Gy of gamma rays (8 U, p <0.004). The Cas II-gly combination 0.1 m M with the pigments does not modify the Sod and Cat activity. These results suggest that the proven pigments act as antioxidants, avoiding the induction of exogenous antioxidants caused by the gamma rays or the Cas II-gly. (Author)

  1. Design of device for testing in the gamma irradiator; Diseno de dispositivo para pruebas en el irradiador gamma

    Energy Technology Data Exchange (ETDEWEB)

    Mariano H, E

    1991-02-15

    In eves of the recharge of the Gamma Irradiator, JS-6500 it was detected, that there was contamination in the container that housed the pencils of Co-60, coming from Argentina, country to which the ININ buys it recharges. It was determined that the contamination in the container was it interns and after discussing several solution options it was determined to manufacture a device to make a washing of the pencils. It was touch to the Management of Radiological Safety to determine the conceptual design of the device to make the washing and the way of operation of the same one. The Management of Prototypes and Models was responsibility of the mechanical design and its production. (Author)

  2. In-situ gamma spectrometry method for determination of environmental gamma dose; Metodo de espectrometria gamma in situ para determinacao de dose gama ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Conti, Claudio de Carvalho

    1995-07-15

    This work tries to establish a methodology for germanium detectors calibration, normally used for in situ gamma ray spectrometry, for determining the environmental exposure rate in function of the energy of the incident photons. For this purpose a computer code has been developed, based on the stripping method, for the computational spectra analysis to calculate the contribution of the partial absorption of the gamma rays (Compton effect) in the active and nonactive parts of the detector. The resulting total absorption spectrum is then converted to fluence distribution in function of the energy for the photons reaching the detector, which is then used to calculate the exposure rate or kerma in air. The unfolding and fluency convention parameters are determined by detector calibration using point gamma sources. The method is validated by comparison of the results against the calculated exposure rate at a point of interest for the standards. This method is used for the direct measurement of the exposure rate distribution in function of the energy at the site, in situ measurement technic, leading to rapid results during an emergency situation and also used for indoor measurements. (author)

  3. TOPO GAMMA - 20: the first crawler in Argentina; TOPO GAMMA - 20: el primer crawler de Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Galli, O; Marin, F; Bigolotti, A D; Cosimano, J J [Control S.R.L., Godoy Cruz (Argentina)

    1998-12-31

    TOPO GAMMA - 20 is a crawler for the radiographying of welding in pipes of 18`` in to 60`` in nominal diameter ranges. This equipment is the first one ever to be designed and built in our country by CONTROL S.R.L. for the radiographying gas pipes or similar installations with a big reduction of operational costs and a considerable improvement in image qualities. The placement of the radioactive source, located in the center of the pipe, enables TOPO GAMMA - 20 perform a complete radiography of the whole weld in a single shot. Furthermore, considering that the wall of the pipe is simple, we shall save time and get much better results than if we used conventional equipment. Also, TOPO GAMMA - 20 has a two camera video system. In this manner, with one of them, we can see all the way along which the device goes through. And with the other, settled to examine in perpendicular way, you can see the roots of the welding. Finally, you can have the results in a video cassette. The whole set is managed by remote control. (author) 3 figs., 1 tab. [Espanol] El TOPO GAMMA - 20 es un crawler para radiografiado en canerias de diametro nominal de 18`` hasta 60``. Este equipo es el primero disenado y construido en el pais por CONTROL S.R.L. para radiografiado de canerias de gasoductos o instalaciones similares, con una gran reduccion de costos operativos y un sustancial incremento en la calidad de imagen obtenida. La disposicion de la fuente radiactiva en el interior del tubo, ubicado en el centro del mismo, permite que el TOPO GAMMA - 20 efectue el radiografiado completo de una soldadura circunferencial de un solo disparo, ademas si tenemos en cuenta que este sistema es de simple pared podemos asegurar que la reduccion de tiempos de radiografiado y radiacion, son drasticos, con respecto a los metodos convencionales desde el exterior. Ademas el TOPO GAMMA - 20 cuenta con un sistema de video con dos camaras, una de ellas permite ver desde el exterior por medio de un monitor de TV el

  4. Determination of the adaptive response induced In vivo by gamma radiation and its relation with the sensibility to the damage induction in the DNA and with the repairing capacity; Determinacion de la respuesta adaptativa inducida In vivo por radiacion gamma y su relacion con la sensibilidad a la induccion de dano en el ADN y con la capacidad de reparacion

    Energy Technology Data Exchange (ETDEWEB)

    Mendiola C, M T

    2002-07-01

    The kinetics of damage induction and repair at different doses as well as the adaptive response induced by gamma ray exposure were determined in murine leukocytes in vivo. The damage-repair kinetics were established after the exposure to 0.5, 1.0 or 2.0 Gy in a {sup 137}Cs source. Peripheral blood samples were obtained from the tails of mice, the percentage of damaged cells and the DNA migration in each one were analyzed by the single cell gel electrophoresis (SCG) technique or comet assay. Results indicated that there was an induction of approximately 75% comets with the doses of 1.0 and 2.0 Gy, which was considerably reduced to 22% and 42% respectively during the first 15 minutes. This evidences the presence of a rapid repair process and suggests that leucocytes are genetically well prepared to repair this kind of damage. After 15 minutes, a second increase in the percentage of damaged cells that was proportional to dose occurred, which seems to represent the breaks produced during the repair of other kind of lesions. After that a second reduction was observed, reaching values near to the basal ones, except with the dose of 2.0 Gy. The kinetics obtained with the dose of 0.5 Gy was similar to that established with 1.0 Gy, but in this case the initial damage was 50 % lower. Besides, the adaptive response was observed after the exposure of the mice to an adaptive dose of 0.01 Gy and to a challenge dose of 1.0 Gy 60 minutes later. The pretreatment reduced the percentage of damaged cells caused by the challenge dose to one third approximately, and also diminished this parameter produced during the late repair process. This indicates that the early adaptive response is caused, instead of by an increment in repair, by the induction of a process that protects DNA from damage induction by radiation, i.e synthesis of substances that increase the scavenging of free radicals. (Author)

  5. Disinfestation of Dried Figs by Gamma Radiation; Desinsectation des figues seches par les rayons gamma; Dezinfestatsiya sushenogo inzhira s pomoshch'yu gamma-izlucheniya'; Desinfestacion de higos secos mediante rayos gamma

    Energy Technology Data Exchange (ETDEWEB)

    Papadopoulou, C. P. [Department of Biology, Democritus Nuclear Research Centre, Aghia Paraskevi, Attica (Greece)

    1963-09-15

    efectuando investigaciones sobre la desinfestacion de los productos agricolas almacenados. En esas investigaciones se han utilizado recientemente con exito los rayos gamma. Los higos secos constituyen uno de los principales productos de exportacion de Grecia y los insectos ocasionan perdidas importantes. Las investigaciones tenian las siguientes finalidades: a) determinar las dosis de radiacion necesarias para destruir ciertas especies de insectos que atacan los higos en diversas fases de su desarrollo, o destruir sus huevos impidiendo asi que se reproduzcan; b) determinar las modificaciones fisicas y quimicas que las radiaciones producen en la contextura de los higos secos. Se han estudiado las especies siguientes: Plodia interpunctella, Ephestia cautella, Carpophilushemipterous, Oryzaephilus surinamensis y Lasioderma serricorne. En la memoria se estudian las dosis optimas de radiacion que no producen dafios aparentes en la contextura de los higos. (author) [Russian] V techenie mnogikh let provodyatsya issledovaniya to voprosam dezinfestatsii sel'skokhozyajstvennykh produktov v khranilishchakh. Nedavno gamma-izluchechie bylo uspeshno primeneno pri provedenii takikh issledovanij. Sushenyj inzhir sostavlyaet odin iz osnovnykh produktov ehksporta Gretsii. Ezhegodno nasekomye nanosyat ser'eznyj ushcherb ehtomu produktu. Tsel' issledovaniya: 1) opredelenie doz izlucheniya, neobkhodimykh dlya unichtozheniya nekotorykh vidov nasekomykh, porazhayushchikh sushenyj inzhir, na razlichnykh stadiyakh ikh razvitiya, i dlya unichtozheniya ikh yaits i predotvrashcheniya takim obrazom ikh razmnozheniya; i 2) opredelenie fiziko-khimicheskikh izmenenij tekstury sushenogo inzhira pod dejstviem izlucheniya. Issledovaniya provodilis' so sleduyushchimi vidami: Plodia Interpunctella, Ephestia coutella, Carpophilus hemipterous, Gryzaephllus surinamensis i Lasioderma serricorne. Obsuzhdayutsya neobkhodimye optimal'nye dozy. Pri ehtikh dozakh ne nablyudaetsya vidimogo narusheniya tekstury inzhira pod

  6. Study of Combined Treatment for Damp-Harvested Maize: Gamma Irradiation and Drying by Controlled Ventilation; Etude d'un Traitement Combine pour le Conditionnement du Mais Recolte Humide: Irradiation Gamma et Sechage par Ventilation Controlee; Izuchenie kombinirovannoj obrabotki kukuruzy molochno-voskovoj spelosti; Estudio de un Tratamiento Combinado para el Acondicionamiento del Maiz Recolectado Humedo: Irradiacion Gamma y Secado por Ventilacion Controlada

    Energy Technology Data Exchange (ETDEWEB)

    Saint-Lebe, L.; Pelegrin, P. [Centre d' Etudes Nucleaires de Cadarache (France); Guilbot, A. [Institut National de la Recherche Agronomique, Massy (France)

    1966-11-15

    optimales de la radiopasteurisation du maies. En possession de ces donnees les auteurs abordent a l'echelle du laboratoire le probleme du traitement combine irradiation-ventilation, dans des conditions experimentales faciles a transposer sur le plan industriel. Ils etudient les modifications microbiologiques et biochimiques qui se produisent dans la fraction des grains humides atteinte en dernier par le flux d'air sechant, ce qui correspond au cas le plus defavorable. D'un point de vue quantitatif, il apparait dans cette zone que l'effet depressif de l'irradiation sur la mycoflore persiste meme apres 26 jours; cet effet est encore plus important sur les bacteries. D'un point de vue qualitatif, on observe la regeneration prioritaire d'une mycoflore precisement sensible au flux d'air sec qui doit l'atteindre. Des applications industrielles sont en vue; mais, avant de passer au stade pilote, phase indispensable a retablissement d'un prix de revient, il est necessaire de mener plus avant des investigations biochimiques. De meme, le point de vue de la sante publique ne devra pas etre neglige pour le cas ou le procede trouverait une application dans le domaine de l'alimentation animale ou humaine. (author) [Spanish] La asociacion de los efectos de la irradiacion gamma con cobalto-60 y del secado lento por ventilacion en frio (10 a 25 Degree-Sign C) en las celdas de almacenamiento se practica con el fin de hallar un sustitutivo a la solucion clasica de secado rapido con aire calentado a alta temperatura, pues el primer tratamiento es mas apropiado para mantener la integridad del grano'y ejerce al mismo tiempo un efecto purificador desde el punto de vista microbiologico. Este problema afecta en Francia a un millon de toneladas de maiz humedo (1964) y cobrara cada vez mas importancia tanto en Europa como en los paises de la zona tropical. Los autores estudian primero la influencia directa de las radiaciones gamma sobre el rendimiento y las caracteristicas tecnicas del almidon. Este

  7. The ionising radiations: a daily reality Las radiaciones ionizantes: una realidad cotidiana

    Directory of Open Access Journals (Sweden)

    Eduardo Gallego Díaz

    2010-12-01

    Full Text Available This paper introduce the nature of the radioactive substances and of the ionising radiation, the effects that they cause on the matter and the available media for their detection and measure, as well as the sources of natural radiation, to which the human being are exposed. Next, in the more detailed part of this paper, it is described the wide range of ionising radiations uses in: medicine, agriculture, earth sciences, biology and in some other scientific fields, that allow to pose its impact in the perspective of facing the ones from natural sources. The article concludes that for avoiding damages it is necessary proper protection against the radioactive substances, but avoiding limitation their beneficial uses in the various ranges described. For finishing this paper, the basic principles of radiation protection are described, due to they are the its principal aim.Este trabajo introduce la naturaleza de las sustancias radiactivas y de la radiación ionizante, los efectos que causa sobre la materia y los medios disponibles para su detección y medida, así como las fuentes de radiación naturales a las que los seres humanos estamos expuestos. Seguidamente, en el apartado más amplio del trabajo, se describen las múltiples aplicaciones de las radiaciones ionizantes en la medicina, la agricultura, la industria, las ciencias de la tierra, la biología y otras ramas, lo que permite poder poner su impacto en perspectiva frente al de las fuentes naturales. La tesis final del artículo es que para evitar sufrir daños resulta necesario protegerse adecuadamente de los efectos nocivos de la radiación y las sustancias radiactivas, pero sin limitar innecesariamente su utilización beneficiosa en los numerosos ámbitos descritos. Ese es el objetivo fundamental de la protección radiológica, cuyos principios básicos se presentan para terminar.

  8. Studies on radiation-image detectors; Etudes sur les detecteurs a images de rayonnements; Izuchenie detektorov izobrazheniya radiatsii; Estudios sobre detectores de radiaciones productores de imagenes

    Energy Technology Data Exchange (ETDEWEB)

    Reiffel, L [Armour Research Foundation, Chicago, IL (United States)

    1962-04-15

    de estas radiaciones. Se concede especial atencion a los detectores capaces de producir imagenes, basados en el principio de la descarga disruptiva de la luminiscencia o de la fosforescencia estimulada. Se han construido contadores de chispa muy grandes, que pesan mas de 100 libras y tienen zonas sensibles de unos 2000 cm{sup 2}, definidas por redes planas alternadas de hasta 400 hilos anodicos y catodicos. Como contadores de flujo gaseoso, utilizando aire o argon-rretano, permiten obtener un sistema sensible a las particulas alfa; la deteccion de neutrones lentos se efectua por medio de placas convertidoras de {sup 10}B enriquecido. Utilizando otros gases de llenado, se ha observado que el contador es sensible a los protones y a los electrones. La lectura de la distribucion de intensidades se efectua por reproduccion fotografica de la distribucion de las chispas. Se han obtenido diagramas de difraccion neutronica de Laue en diez minutos, utilizando el reactor de investigaciones de Armour en regimen de baja potencia; el flujo maximo en el nucleo fue de 10{sup 11} nv y se utilizo como colimador un tubo recto de 1 cm x 1 cm. El autor describe las aplicaciones de estos contadores a otros estudios sobre neutrones y expone consideraciones sobre el poder de resolucion que se podra obtener con menor separacion entre los electrodos, exploracion dinamica y, posiblemente, filtrado espacial de la imagen optica. Otro metodo para abordar la deteccion de radiaciones con reproduccion de imagenes consiste en el empleo de pantallas convertidoras de material luminiscente o fosforescente. Se estan ensayando matrices de fibras luminiscentes compuestas de tubos de vidrio muy finos, rellenos de un liquido centelleador. Estas matrices son utiles para detectar rayos X y rayos gamma, y es posible el material de los tubos o el liquido de relleno para hacerlas sensibles a los neutrones. El autor describe nuevos metodos para fabricar varios tipos de pantallas de fibra luminiscente y

  9. Influence of terrestrial radionuclides on environmental gamma exposure in a uranium deposit in Paraíba, Brazil.

    Science.gov (United States)

    Araújo Dos Santos Júnior, José; Dos Santos Amaral, Romilton; Simões Cezar Menezes, Rômulo; Reinaldo Estevez Álvarez, Juan; Marques do Nascimento Santos, Josineide; Herrero Fernández, Zahily; Dias Bezerra, Jairo; Antônio da Silva, Alberto; Francys Rodrigues Damascena, Kennedy; de Almeida Maciel Neto, José

    2017-07-01

    One of the main natural uranium deposits in Brazil is located in the municipality of Espinharas, in the State of Paraíba. This area may present high levels of natural radioactivity due to the presence of these radionuclides. Since this is a populated area, there is need for a radioecological dosimetry assessment to investigate the possible risks to the population. Based on this problem, the objective of this study was to estimate the environmental effective dose outdoors in inhabited areas influenced by the uranium deposit, using the specific activities of equivalent uranium, equivalent thorium and 40 K and conversion factors. The environmental assessment was carried using gamma spectroscopy in sixty-two points within the municipality, with a high-resolution gamma spectrometer with HPGe semiconductor detector and Be window. The results obtained ranged from 0.01 to 19.11 mSv y -1 , with an average of 2.64 mSv y -1 . These levels are, on average, 23 times higher than UNSCEAR reference levels and up to 273 times the reference value of the earth's crust for primordial radionuclides. Therefore, given the high radioactivity levels found, we conclude that there is need for further investigation to evaluate the levels of radioactivity in indoor environments, which will reflect more closely the risks of the local population. Copyright © 2017 Elsevier Inc. All rights reserved.

  10. Analysis and adaptation of a mathematical model for the prediction of solar radiation; Analisis y adaptacion de un modelo matematico de prediccion de radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, Lorenzo [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1987-12-31

    There is an abundant, reliable, free, source of energy whose use can be planned and besides, practicably inexhaustible: the solar energy. In Mexico it constitutes an important resource, because of its geographical position; for this reason it is fundamental to know it well, either by means of measurements conducted for several years or by mathematical models. These last ones predict with meteorological variables, the values of the solar radiation with acceptable precision. At the Instituto de Investigaciones Electricas (IIE) a model is studied for the prediction of the solar radiation to be adapted to the local conditions of Mexico. It is used in simulation studies of the solar plants functioning and other solar systems. [Espanol] Existe una fuente de energia abundante, confiable, gratuita, cuyo uso puede planearse y, ademas, es practicamente inagotable: la solar. En Mexico constituye un recurso importante, por la posicion geografica del pais; por eso es fundamental conocerlo bien, ya mediante mediciones realizadas durante algunos anos, ya mediante modelos matematicos. Estos ultimos predicen, con datos de variables meteorologicas, los valores de la radiacion solar con precision aceptable. En el Instituto de Investigaciones Electricas (IIE) se estudia un modelo de prediccion de radiacion solar para adaptarlo a las condiciones locales de Mexico. Se usa en estudios de simulacion del funcionamiento de plantas helioelectricas y otros sistemas solares.

  11. Analysis and adaptation of a mathematical model for the prediction of solar radiation; Analisis y adaptacion de un modelo matematico de prediccion de radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Zambrano, Lorenzo [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1986-12-31

    There is an abundant, reliable, free, source of energy whose use can be planned and besides, practicably inexhaustible: the solar energy. In Mexico it constitutes an important resource, because of its geographical position; for this reason it is fundamental to know it well, either by means of measurements conducted for several years or by mathematical models. These last ones predict with meteorological variables, the values of the solar radiation with acceptable precision. At the Instituto de Investigaciones Electricas (IIE) a model is studied for the prediction of the solar radiation to be adapted to the local conditions of Mexico. It is used in simulation studies of the solar plants functioning and other solar systems. [Espanol] Existe una fuente de energia abundante, confiable, gratuita, cuyo uso puede planearse y, ademas, es practicamente inagotable: la solar. En Mexico constituye un recurso importante, por la posicion geografica del pais; por eso es fundamental conocerlo bien, ya mediante mediciones realizadas durante algunos anos, ya mediante modelos matematicos. Estos ultimos predicen, con datos de variables meteorologicas, los valores de la radiacion solar con precision aceptable. En el Instituto de Investigaciones Electricas (IIE) se estudia un modelo de prediccion de radiacion solar para adaptarlo a las condiciones locales de Mexico. Se usa en estudios de simulacion del funcionamiento de plantas helioelectricas y otros sistemas solares.

  12. Counseling patients exposed to ionizing radiation during pregnancy El asesoramiento de pacientes expuestas a radiaciones ionizantes durante el embarazo

    Directory of Open Access Journals (Sweden)

    Robert L. Brent

    2006-09-01

    testes. Counseling patients requires knowledge of embryology, genetics, radiation teratology, and the principles of teratology in order for the counselor to provide sympathetic, accurate, scholarly advice.Los físicos que trabajan en el ámbito de la salud y los clínicos que tienen conocimientos de radiología tienen la responsabilidad de asesorar a las mujeres de edad fecunda acerca de los riesgos reproductivos de la exposición a radiaciones ionizantes antes de la concepción o durante el embarazo. Es importante entender que las personas legas albergan muchas nociones equivocadas acerca de los riesgos asociados con ese tipo de radiaciones. Muchas pacientes que ya se han sometido o serán sometidas a algún tipo de prueba radiológica les temen a los correspondientes riesgos reproductivos y a las posibles consecuencias de estas pruebas diagnósticas para el desarrollo fetal. Según estudios epidemiológicos y con animales, un alto grado de exposición a radiaciones ionizantes puede provocar un aborto, anomalías congénitas, retraso del crecimiento, muerte fetal y cáncer. A salvedad de esto último, hay umbrales de exposición establecidos en relación con cada uno de estos problemas, y una exposición por debajo de ciertas dosis de radiación no se asocia con ninguna elevación del riesgo de sufrir daños reproductivos o del desarrollo. El umbral de exposición asociado con anomalías congénitas durante la etapa del desarrollo de mayor vulnerabilidad es de 0,2 Gy, y el umbral en el caso del retraso del crecimiento y del aborto espontáneo es aun mayor. No obstante, la pérdida de un embrión puede ocurrir incluso a dosis bajas durante las fases del desarrollo que preceden a la implantación o en la fase presomática (el llamado período de "todo o nada". Esta es la etapa en que un embrión corre un mayor riesgo de morir que de sobrevivir con malformaciones. El período de mayor vulnerabilidad para la inducción de retraso mental dura desde la octava hasta la

  13. The Importance of Dosimetry to the Medical Management of Persons Accidentally Exposed to High Levels of Radiation; Le Role de la Dosimetrie Dans les Soins Medicaux a Donner aux Personnes Accidentellement Exposees a de Fortes Doses de Rayonnement; 0417 041d 0410 0427 0414 ; Importancia de la Dosimetria para el Tratamiento Medico de las Personas Accidentalmente Expuestas a Dosis Elevadas de Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Andrews, G. A.; Lushbaugh, C. C. [Medical Division, Oak Ridge Institute of Nuclear Studies (United States); Auxier, J. A. [Health Physics Division, Oak Ridge National Laboratory, Oak Ridge, TN (United States)

    1965-06-15

    Radiation accidents continue to occur sporadically and it appears that there is no hope of eliminating them entirely. The management of patients exposed to large doses of radiation is constantly improving because of increasing ability to prevent and treat infection and to control haemorrhage. The possible effectiveness of temporary bone marrow grafts offers promise of a further reduction in mortality. The use of this growing biological information is closely related to, and to a large extent dependent upon, improvements in physical dosimetry for radiation accidents. (author) [French] Des accidents provoques par les rayonnements continuent a se produire de temps a autre et il ne semble guere que l'on puisse esperer les eliminer entierement. Toutefois, le traitement des sujets exposes a de fortes doses de rayonnement ne cesse de s'ameliorer; on parvient, en effet, dans une mesure croissante a empecher et a traiter l*infection ainsi qu'a arreter l'hemorragie. Comme la greffe temporaire de la moelle des os semble devoir donner des resultats, on peut s*attendre a une nouvelle reduction du taux de mortalite. L'application de ces connaissances biologiques sans cesse accrues est fonction, dans une large mesure, des ameliorations apportees a la dosimetrie physique des accidents nucleaires. (author) [Spanish] De vez en cuando se siguen produciendo accidentes de irradiacion y las perspectivas de evitarlos por completo parecen ser bastante remotas. El tratamiento de las victimas expuestas a dosis elevadas de radiaciones mejora constantemente debido a la creciente posibilidad de prevenir y tratar las infecciones, y de controlar las hemorragias. Tambien es posible que la eficacia de ios injertos temporales de medula osea se traduzca en una disminucion de la mortalidad. El aprovechamiento de estos conocimientos biologicos cada vez mas amplios guarda una estrecha relacion con los perfeccionamientos en materia de dosimetria fisica en caso de accidentes de irradiacion. (author

  14. Consecuencias del estrés oxidativo de la piel por radiaciones ultravioleta

    OpenAIRE

    Alvarez Fontanet, Ernesto

    1995-01-01

    Se ha avanzado en el conocimiento de la participación de las especies reactivas del oxígeno en la fisiopatología de muchas entidades y fenómenos patológicos. La piel es probablemente uno de los órganos que con mayor frecuencia sufre estrés oxidativo. Las radiaciones ultravioleta constituyen el principal factor generador de estrés oxidativo a este nivel. El fotoestrés oxidativo de la piel por radiaciones ultravioleta está mediado por diferentes mecanismos y favorecido por diversas circunstanci...

  15. Calculation of the hydrogen produced by a PEM electrolyzer based on solar radiation in Zacatecas; Estimacion del hidrogeno producido por un electrolizador PEM a partir de la radiacion solar en Zacatecas

    Energy Technology Data Exchange (ETDEWEB)

    Duron-Torres, S. M.; Villagrana-Munoz, L.E.; Garcia-Saldivar, V.M. [Universidad Autonoma de Zacatecas, Zacatecas (Mexico)]. E-mail: duronsm@prodigy.net.mx; Arriaga-Hurtado, L.G. [Centro de Investigacion y Desarrollo Tecnologico en Electroquimica, Pedro Escobedo, Queretaro (Mexico)

    2009-09-15

    radiacion solar. La cantidad de irradiacion promedio medida fue de 6.6 kW-h/ m{sup 2}. La evaluacion del Sistema solar-hidrogeno se realizo mediante regresiones lineales del comportamiento del Flujo de Hidrogeno en LN/min contra la Irradiancia Solar en W/m{sup 2} para un electrolizador tipo PEM. Los resultados obtenidos indican que se tiene una maxima produccion de hidrogeno para el mes de abril con un valor de produccion de hidrogeno de 9 LN /min, a una intensidad de radiacion cercana a 900 W/m{sup 2} y un minimo de 6 LN/min para una radiacion cercana a 600 W/m{sup 2} en el mes de diciembre. Con base a estos resultados, podemos prever una cantidad de hidrogeno entre 6 y 9 LN/min generados en el estado de Zacatecas, como valores minimos a generar durante todo el ano, ya que los meses evaluados son los de menor radiacion solar. Las mediciones realizadas en la Estacion Siglo XXI demuestran que el potencial medido de radiacion solar es superior a la media nacional y mundial, lo que hace de Zacatecas un estado estrategico para la utilizacion de esta energia renovable. Las cantidades calculadas de hidrogeno producido indicarian que es factible el establecimiento en esta region de sistemas solar-hidrogeno para la obtencion de este vector energetico empleando electrolizadores tipo PEM.

  16. Semiconductor scintillator detector for gamma radiation; Detector cintilador semicondutor para radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laan, F.T.V. der; Borges, V.; Zabadal, J.R.S., E-mail: ftvdl@ufrgs.br, E-mail: borges@ufrgs.br, E-mail: jorge.zabadal@ufrgs.br [Universidade Federal do Rio Grande do Sul (GENUC/DEMEC/UFRGS), Porto Alegre, RS (Brazil). Grupo de Estudos Nucleares. Departamento de Engenharia Mecanica

    2015-07-01

    Nowadays the devices employed to evaluate individual radiation exposition are based on dosimetric films and thermoluminescent crystals, whose measurements must be processed in specific transductors. Hence, these devices carry out indirect measurements. Although a new generation of detectors based on semiconductors which are employed in EPD's (Electronic Personal Dosemeters) being yet available, it high producing costs and large dimensions prevents the application in personal dosimetry. Recent research works reports the development of new detection devices based on photovoltaic PIN diodes, which were successfully employed for detecting and monitoring exposition to X rays. In this work, we step forward by coupling a 2mm anthracene scintillator NE1, which converts the high energy radiation in visible light, generating a Strong signal which allows dispensing the use of photomultipliers. A low gain high performance amplifier and a digital acquisition device are employed to measure instantaneous and cumulative doses for energies ranging from X rays to Gamma radiation up to 2 MeV. One of the most important features of the PIN diode relies in the fact that it can be employed as a detector for ionization radiation, since it requires a small energy amount for releasing electrons. Since the photodiode does not amplify the corresponding photon current, it must be coupled to a low gain amplifier. Therefore, the new sensor works as a scintillator coupled with a photodiode PIN. Preliminary experiments are being performed with this sensor, showing good results for a wide range of energy spectrum. (author)

  17. Heat transfer study for convection and radiation in an open cavity; Estudio de de la transferencia de calor por convencion y radiacion en una cavidad abierta

    Energy Technology Data Exchange (ETDEWEB)

    Cabanillas Lopez, Rafael E [Universidad de Sonora, Hermosillo, Sonora (Mexico); Estrada Gasca, Claudio A [Centro de Investigacion en Energia-UNAM, Temixco, Morelos (Mexico); Alvarez Garcia, Gabriela S [CENIDET, Cuernavaca, Morelos (Mexico)

    2000-07-01

    Interaction of natural convection and radiation heat transfer in an open side square cavity has been simulated numerically. Previous studies have shown results of the simulation of heat transfer for convection on this geometry. This paper reports the effect of considering both the convection and the radiation mechanisms. Radiation was found to have a great influence on the total amount of heat lost by the cavity as well as on the pattern of flow and on the temperature field. Computations were performed within the domain of the cavity for two-dimensional laminar flow problem. The average of heat transfer coefficient was calculated for several values of the Grashof number for air (Pr = 0.7), with the bottom wall at 500 K (constant temperature) and the open side at 300 K. [Spanish] Se presenta el estudio de la interaccion conveccion natural-radiacion en una cavidad rectangular abierta. Algunos estudios anteriores han mostrado resultados sobre la transferencia de calor por el mecanismo de conveccion natural sobre cavidades abiertas. Aqui se presenta la influencia de considerar ambos mecanismos de transferencia de calor, la conveccion y la radiacion. Se demuestra que el intercambio radiactivo tiene una gran influencia tanto en la cantidad total de calor perdido por la cavidad al ambiente, como en el patron de flujo y de temperatura dentro de la cavidad. Se resuelven numericamente las ecuaciones gobernantes para flujo laminar en dos dimensiones y se calcula el coeficiente promedio de transferencia de calor para diferentes valores del Grashof en una cavidad llena de aire (Pr 0.7), teniendo la pared del fondo de la cavidad a 500 K y los alrededores a 300 K.

  18. Description of morphologic characters in avocado trees (Persea americana. Mill) var. Hass, submitted to gamma radiation of {sup 60} Co; Descripcion de caracteres morfologicos en arboles de aguacate (Persea americana. Mill) var. Hass, sometidos a radiacion gama de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, L

    2004-07-01

    It was carried out the characterization of 77 trees of avocado ''Hass'' subjected to gamma radiation of Co{sup 60}, in doses of 0, 5, 10,15, 20 and 25 Gy based on previous studies of radiosensitivity with ends of improvement located in the experimental center ''La Labor'' belonging to the foundation Salvador Sanchez Colin. CICTAMEX. S C. in Temascaltepec, Mexico. It was carried out the morphological characterization of this variety according to the nomenclature settled down by the International Office of Genetic Resources (IBPGRI), registering 27 variables for the description of the tree, 33 for description of the fruit and 14 for the characterization of the seed. Regarding the architectural characterization 10 variables were evaluated. Using gamma radiation of Co{sup 60} in the doses of 15 and 20 Gy it was detected a reduction of 22% in the portage of the tree, likewise had reduction the diameter of the trunk and of the foliage. It was found that the reduction in the behavior of the tree induces to a bigger variation of the form of the same one, in the distribution of the branches in the form of the fruit and in the form of the seed you Also detects a remarkable increment in the productivity of some hoist irradiated regarding the architecture of the tree one observes that the angle of inclination of the branches increase when being increased the radiation dose and that the longitude of the annual section of growth decreased significantly in the doses of 20 and 25 Gy. One observes a significant Increment in the I number of buds prolepticos in those hoist irradiated in the I finish mbdulo of rhythmic growth. Io that indicates a change substantial in the I inhabit of growth With the purpose of determining if the changes in morphology and architecture of the tree corresponded with the modification at level meristematico, they were carried out observations to the court microscope of having knitted apical vegetative meristematico in samples of you hoist of all the

  19. Description of morphologic characters in avocado trees (Persea americana. Mill) var. Hass, submitted to gamma radiation of {sup 60} Co; Descripcion de caracteres morfologicos en arboles de aguacate (Persea americana. Mill) var. Hass, sometidos a radiacion gama de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Sandoval R, L

    2004-07-01

    It was carried out the characterization of 77 trees of avocado ''Hass'' subjected to gamma radiation of Co{sup 60}, in doses of 0, 5, 10,15, 20 and 25 Gy based on previous studies of radiosensitivity with ends of improvement located in the experimental center ''La Labor'' belonging to the foundation Salvador Sanchez Colin. CICTAMEX. S C. in Temascaltepec, Mexico. It was carried out the morphological characterization of this variety according to the nomenclature settled down by the International Office of Genetic Resources (IBPGRI), registering 27 variables for the description of the tree, 33 for description of the fruit and 14 for the characterization of the seed. Regarding the architectural characterization 10 variables were evaluated. Using gamma radiation of Co{sup 60} in the doses of 15 and 20 Gy it was detected a reduction of 22% in the portage of the tree, likewise had reduction the diameter of the trunk and of the foliage. It was found that the reduction in the behavior of the tree induces to a bigger variation of the form of the same one, in the distribution of the branches in the form of the fruit and in the form of the seed you Also detects a remarkable increment in the productivity of some hoist irradiated regarding the architecture of the tree one observes that the angle of inclination of the branches increase when being increased the radiation dose and that the longitude of the annual section of growth decreased significantly in the doses of 20 and 25 Gy. One observes a significant Increment in the I number of buds prolepticos in those hoist irradiated in the I finish mbdulo of rhythmic growth. Io that indicates a change substantial in the I inhabit of growth With the purpose of determining if the changes in morphology and architecture of the tree corresponded with the modification at level meristematico, they were carried out observations to the court microscope of having knitted apical vegetative meristematico

  20. Effects of Ionizing Radiation on Insects and Other Arthropods; Effet des rayonnements ionisants sur les insectes et autres arthropodes; Vozdejstvie ioniziruntsej radiatsii na nasekomykh i drugikh chlenistonogikh; Efectos de las radiaciones ionizantes sobre los insectos y otros artropodos

    Energy Technology Data Exchange (ETDEWEB)

    Stone, William E. [United States Department of Agriculture Laboratories, Mexico City, D.F (Mexico)

    1963-09-15

    radiaciones gamma en la capacidad de reproduccion, los instintos sexuales, el vigor y la longevidad de la mosca oriental de la fruta, Dacus dorsalis Hendel, la mosca del melon, Dacus cucurbitae Coq., la mosca mediterranea, Ceratitis capitata Wied., la mosca de la fruta mejicana, Anastrepha ludens Loew, y el Anopheles quadrimaculatus Say, e indica los resultados de la campada de exterminio obtenidos en la practica liberando machos esteriles. Revisa tambien los progresos realizados en los Estados Unidos en la campana para exterminar la Cochliomya hominivorax Cqrl., y en los estudios para desarrollar cepas vigorosas, marcadas geneticamente, que permitan identificar con facilidad las moscas esteriles liberadas. Se discuten tambien los resultados de las investigaciones sobre la irradiacion de otras seis especies que atacan a frutas, verduras y otros cultivos agricolas y forestales, otras tres que atacan al ganado, y tres mas que atacan principalmente al hombre. Se trata asimismo de la irradiacion del escorpion, Centruroides limp idus Karsch y del aracnido Amblyomma americanum L., y de la posibilidad de emplear radiaciones ionizantes como tratamiento de cuarentena para las frutas y verduras infestadas con la mosca de la fruta y para los mangos infestados con el gorgojo Stemochetus mangiferae Fabricius. (author) [Russian] V nastoyashchee vremya provodyatsya issledovaniya vozmozhnosti primeneniya metoda sterilizatsii posredstvom oblucheniya dlya unichtozheniya populyatsij tselogo ryada nasekomykh, porazhaptsikh cheloveka, zhivotnykh i razlichnye kul'tury. Ehti predvaritel'nye issledovaniya pokazali, chto ioniziruyushchee obluchenie privodit k sterilizatsii, no chto dlya ehtoj tseli trebuyutsya chrezvychajno raznoobraznye dozy. Okazalos', chto v nekotorykh sluchayakh radiatsionnye povrezhdeniya mogut isklyuchit' vozmozhnost' primeneniya ehtogo metoda u nekotorykh nasekomykh. Prepyatstvie, kotoroe zachastuyu prikhoditsya preodolevat', zaklyuchaetsya v otsutstvii prakticheskikh metodov

  1. DELIN and DELOG codes for graphic representation of gamma ray spectra; Programas DELIN y DELOG para la representacion grafica de espectros gamma

    Energy Technology Data Exchange (ETDEWEB)

    Romero, L; Travesi, A

    1983-07-01

    Two Fortran IV Codes has been developed for graphic representation of the gamma-ray spectra obtained with Ge Li detectors and multichannel analyzers. The grafic plotting es carried out with the H.P. Graphic Plotter Mod HP-7221 A, using the graphic package software GRAPHICS-1000 from Hewlett-Packard. The codes have a great versatility and the representation of gamma spectra can ba done in a lineal, semi log, or log-log scale, as desired. The gamma ray spectra data are feed into the computer through magnetic tape or perfored paper tape. The different out-put options and complementary data are given in a conversational way through a terminal with T.V. displays. Among the options that can be selected by the user are the following: - smoothing the spectra - drawing the spectra point by point or continuous - out-put drawing an 1, 2, or 4 sheet with automatic division of the energy scale. - overlapping of selected spectra regions in Y scale ampliation with automatic print-out of the region limits and ampliation factor. - Printing spectra data and identifications of selected photo peaks. The codes can be employed with any computer using printing devices, HP-Graphics 1000 software compatible, but are easily modified for another printing software since their modular structure with Fortran IV written.

  2. Comparative Study of the Methods Used for the Computer Resolution of Composite Gamma-Ray Spectra; Etude Comparative des Methodes Utilisees pour la Resolution de Spectres Gamma Complexes au Moyen d'un Ordinateur; Sravnitel'noe izuchenie metodov razresheniya sostavnykh gamma-spektrov pri pomoshchi schetno-reshayushchego ustrojstva; Estudio Comparativo de los Metodos Aplicados para Resolver Espectros Gamma Complejos Mediante Calculadoras

    Energy Technology Data Exchange (ETDEWEB)

    DeHaan, A. Jr.; Leventhal, L.; Benson, P. [Tracerlab, Richmond, CA (United States)

    1965-10-15

    'a resolution; 2. Resolution du pic sans elimination; 3. Etablissement d'un ensemble d'equ'ations lineaires simultanees du meme ordre que le nombre de radionucleides presents dans le melange et solution de ces equations; 4. Evaluation des concentrations non connues par la methode des moindres carres, classique ou ponderee; 5. Combinaison des methodes statistiques et des methodes des moindres carres utilisant la regression lineaire multiple progressive, en s'efforcant d'integrer des processus decisifs dans l'analyse. Pour chaque methode d'analyse appliquee a des melanges de radionucleides, les auteurs fournissent une estimation statistique des erreurs de mesure de la concentration des radionucleides. (author) [Spanish] La resolucion de mezclas complejas de emisores gamma se ha simplificado gracias al empleo de espectrometros gamma muy perfeccionados en asociacion con calculadoras numericas. En la actualidad, los laboratorios pueden en general disponer de estos instrumentos o tener facilmente acceso a ellos. En la memoria se examinan los metodos seguidos en el laboratorio de los autores para determinar la concentracion de cada radionuclido emisor gamma contenido en muestras de precipitaciones radiactivas, y se comparan los resultados obtenidos por los diferentes metodos matematicos aplicables a las muestras compuestas. Los datos proporcionados por las calculadoras se comparan con los resultados obtenidos por analisis radioquimico de la muestra. Se han analizado muestras binarias por los metodos mencionados, operacion que se extendio despues a las mezclas integradas por muchos componentes. Se ha elaborado un metodo de computo que normaliza los espectros gamma para reducir al mfnimo el efecto de la deriva del espectrometro a largo plazo, y representa el espectro segun un sistema de coordenadas, una de las cuales es la energia. Se han investigado los efectos de un 'fotopico imprevisto', de una componente de intensidad cero y de picos superpuestos en la resolucion segun los

  3. Program LEP to addition of gamma spectra from germanium detectors; Programa LEPS para suma de espectros gammas de detectores de germanio

    Energy Technology Data Exchange (ETDEWEB)

    Romero, L

    1986-07-01

    The LEP program, written in FORTRAN IV, performs the addition of two spectra, collected with different detectors, from the same sample. This application, adds the two gamma spectra obtained from two opposite LEPS Germanium Detectors (Low Energy Photon Spectrometer), correcting the differences (channel/energy) between both two spectra, and fitting them before adding. The total-spectrum is recorded at the computer memory as a single spectrum. The necessary equipment, to run this program is: - Two opposite germanium detectors, with their associate electronics. - Multichannel analyzer (2048 memory channel minimum) - Computer on-line interfacing to multichannel analyzer. (Author) 4 refs.

  4. Análisis integral del marco normativo colombiano en materia de exposición pública a radiaciones electromagnéticas emitidas por estaciones base de telefonía móvil

    Directory of Open Access Journals (Sweden)

    Lina María Gallego Serna

    2014-05-01

    Full Text Available En el presente artículo se analiza de forma integral el marco normativo colombiano referente a la exposición del público a las radiaciones electromagnéticas emitidas por estaciones base de telefonía móvil. Por consiguiente, se dividió el marco legal vigente en siete tópicos principales: las telecomunicaciones, el uso del espectro electromagnético, los límites de exposición a campos electromagnéticos, las licencias urbanísticas, la salud pública, el aspecto ambiental y la gestión del riesgo. Asimismo, se valoraron la naturaleza y los alcances del principio de precaución frente al mismo. Finalmente, se determinó que Colombia no cuenta con un precepto legal que garantice la seguridad de la población ante los posibles efectos nocivos por la exposición a las radiaciones no ionizantes; igualmente, no se ha empleado el principio de precaución para establecer medidas que garanticen la seguridad de los ciudadanos en lo referente a radioprotección.

  5. Procedure to carry out leakage test in beta radiation sealed sources emitters of {sup 90}Sr/{sup 90}Y; Procedimiento para realizar prueba de fuga en fuentes selladas de radiacion beta emisoras de {sup 90}Sr/{sup 90}Y

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.m [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Laboratorio Secundario de Calibracion Dosimetrica, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In the alpha-beta room of the Secondary Laboratory of Dosimetric Calibration of the Metrology Department of Ionizing Radiations ophthalmic applicators are calibrated in absorbed dose terms in water D{sub w}; these applicators, basically are emitter sealed sources of pure beta radiation of {sup 90}Sr / {sup 90}Y. Concretely, the laboratory quality system indicates to use the established procedure for the calibration of these sources, which establishes the requirement of to carry out a leakage test, before to calibrate the source. However, in the Laboratory leakage test certificates sent by specialized companies in radiological protection services have been received, in which are used gamma spectrometry equipment s for beta radiation leakage tests, since it is not reliable to detect pure beta radiation with a scintillating detector with NaI crystal, (because it could detect the braking radiation produced in the detector). Therefore the Laboratory has had to verify the results of the tests with a correct technique, with the purpose of determining the presence of sources with their altered integrity and radioactive material leakage. The objective of this work is to describe a technique for beta activity measurement - of the standard ISO 7503, part 1 (1988) - and its application with a detector Gm plane (type pankage) in the realization of leakage tests in emitter sources of pure beta radiation, inside the mark of quality assurance indicated by the report ICRU 76. (Author)

  6. Determination of the correction factor for attenuation, dispersion and production of electrons (K{sub wall}) in the wall of graphite of a ionization chamber Pattern National Type CC01 in fields of gamma radiation of {sup 60}Co; Determinacion del factor de correccion por atenuacion, dispersion y produccion de electrones (K{sub wall}) en la pared de grafito de una Camara de Ionizacion Patron Nacional Tipo CC01 en campos de radiacion gamma de {sup 60} Co

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T.; Morales P, J.; Cruz E, P. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    2001-12-15

    It was determined the Kwall correction factor for the wall of graphite of the chamber of the pattern national type CC01 series 133 for a radiation field Gamma of {sup 60}Co. With this end to measured the currents of ionization l(x) as function of the thickness of the wall of the chamber: X=4,8,12,16 and 20 mm.The mensurations for each thickness consisting of three groups, of sizes n = 30 or 60 data for each group; obtaining 8 complete groups of mensurations independent in eight different dates.The determinate the factor carried out using three regression models: lineal, logarithmic and quadratic, models that were tried to validate with the tests of : i) Shapiro-Wilk and {chi}{sup 2} for the normality of the entrance data ii) Tests of Bartlett for variances homogeneity among groups for each thickness iii) The tests of Duncan for the stockings among groups of each thickness, and iv) The tests of adjustment lack (LOF) for the models used. Nevertheless, alone the models of the group of corresponding mensurations at 01-03-2000 17-08-2001 they can be validated by LOF, but not for tests of normality and homogeneity of variances. Among other assignable causes of variation we have: i) The values captured by the system of mensuration of the variables of it influences: pressure, temperature and relative humidity don{sup t} belong together with the existent ones to the moment to capture the l(x). ii) The mensuration room presents flows of air, for what was suited o diminish their volume and to eliminate the flows of air. iii) A protocol settled down of taking of measures that it consisted in: - Pre-irradiation 5 minutes the chamber after the change of polarity and hood change, with a period of stabilization of 5 minutes after the pre-irradiation. - Pre-irradiation for 5 minutes before the taking of the readings, with the object of eliminating variation sources assigned to currents of escapes or due variations to transitory. iv) To realize corrections for relative humidity of

  7. COMPARACIÓN DE LA CROMATOGRAFÍA DE LÍQUIDOS Y LA ELECTROFORESIS CAPILAR EN ESTUDIOS DE QUÍMICA DE RADIACIONES: SEPARACION DE PRODUCTOS RADIOLITICOS

    Directory of Open Access Journals (Sweden)

    Guadalupe Albarrán

    2017-01-01

    Full Text Available Avances en Ciencias e Ingeniería - ISSN: 0718 - 8706 Av. cien. ing.: 8(1, 43 - 49 (Enero/Marzo, 2017 A l barrán et al . http://www.exeedu.com/publishing.cl/av_cienc_ing/ 43 COMPARACIÓN DE LA CROMATOGRAFÍA DE LÍQUIDOS Y LA ELECTROFORESIS CAPILAR EN ESTUDIOS DE QUÍMICA DE RADIACIONES: SEPARACIO N DE PRODUCTOS RADIOLITICOS COMPARISON OF L IQUID C H ROMATOGRAPHY AND CAPILLARY ELECTROPHORESIS IN STUDIES ON RADIAT ION CHEMISTRY: SEPAR A TION OF RADIOLYTIC PRODUCTS Guadalupe Albarrá n 1 , Edith Mendoza 1 , Maribel Esparza 1 (1 Universidad Nacional Autónoma de México , Instituto de Ciencias Nucleares, Circuito Exterior, C iudad U niversitari a , Cd. de México , 04510 México (e - mail: albarran@nuclear es.unam.mx Recibido: 22 /0 9 /2016 - Evaluado: 20 /10/2016 - Aceptado: 05 / 11 /2016 RESUMEN El objetivo de este trabajo es comparar los resultados obtenidos de dos métodos para la identificación y cuantificación de los productos radiolíticos de soluciones diluidas de ácidos hidroxibenzoicos. Soluciones acuosas de cada ácido fueron irradiadas y analizadas utilizando una columna Alltima C18 (50x4.6 mm, fase móvil una mezcla de metanol, una solución 5 mmol/L de ácido 1 - hexansulfónico y 1% de ácido acético para cromatografía de líquidos y para electroforesis capilar se utilizó u na columna capilar de 72cmx75μm, celda de alta sensibilidad, voltaje de 25kV y una solución amortiguadora de boratos 10 mmol/L, pH 9.3 y 50 mmol/L de SDS. En la cinética de formación de los productos radiolíticos se obtuvieron concentraciones aproximadas. Los resultados obtenidos proporcionan amplia información a la Química de Radiaciones en determinar la distribución de carga en el anillo aromático.

  8. Dosis óptima de irradiación gamma con Co60 para inducción de mutagénesis en pastos

    Directory of Open Access Journals (Sweden)

    Alan Álvarez-Holguín

    2017-01-01

    Full Text Available La dosis letal (DL 50 y reducción media del crecimiento (RC 50 son parámetros utilizados para seleccionar dosis de irradiación adecuadas e inducir mutaciones para realizar mejoramiento genético vegetal. El objetivo fue determinar la DL 50 y RC 50 para conocer la dosis ó p tima de irradiación c on Co 60 en semilla de pasto llorón, buffel, banderita y navajita. Se evaluaron seis dosis de irradiación con Co 60 en semilla : 100, 200, 300, 450, 600 y 900 Gray (Gy y un tratamiento control (T - 0, sin irradiación. Las variables evaluadas fueron : porcentaj e de germinación (%GE, índice de velocidad de germinación (IVG, longitud de plúmula (LP y longitud de radícula (LR. Se realizó análisis de regresión y comparación de medias con la prueba de Dunnett. Mediante la ecuación de regresión se estimó la DL 50 p ara el %GE, así como RC 50 para el resto de las variables. La DL 50 se ponderó con 55%, mientras que la RC 50 se ponderó en 15% para cada una de las tres variables restantes. En general, los valores de las variables disminuyeron (P<0.05 conforme se incremen tó la dosis de irradiación, lo cual permitió determinar la DL 50 y RC 50 para cada especie. La media ponderada se obtuvo a los 628 Gy, 712 Gy, 698 Gy y 411 Gy para pasto llorón, buffel, banderita y navajita, respectivamente. Se recomiendan las dosis plantead as en este estudio, ya que esto permitirá plantear las bases para realizar mejoramiento genético a través de mutagénesis con irradiación gamma en los pastos evaluados.

  9. Application of the gamma rays backscattering for determining the quantity of steel; Aplicacion de la tecnica de retrodispersion de los rayos gamma para determinar la cuantia del acero

    Energy Technology Data Exchange (ETDEWEB)

    Huapaya P, B F

    1996-11-01

    This work tries to purpose a methodology based on the nuclear technology available in the country, for measuring the position and diameter of the reinforcing rods placed in reinforced concrete structures. The technique of gamma backscattering that utilizes the changes of density was used for determining the presence of steel (average density of concrete 2,5 g/cm{sup 3} and steel 7,8 g/cm{sup 3}). The concrete test tubes of different resistances were prepared with diverse concentrations into the aggregates as crushed rock and coarse sand, and also with three steel rods of 0,5 inch separated by 4 inches among themselves. The source Cs-137 of 20 mCi in activity was a monoenergetic radioisotope of the element Cs from 662 KeV. The source was placed in a lead shield with a hole which generates a collimator beam of 2 mm. The detector was one type of scintillation (INa-Tl) 2 x 2 inch; it was sealed with lead and had a hole of 10 mm which worked as collimator. The shield was placed in an angle of 15 degrees over concrete surface in order to pick up the backscattering gamma rays by the concrete. The test tube was displaced over a little car affixed to a endless screw which permitted to reproduce displacements of 0,25 inch. The data recording was realized through a multichannel of 1024 channels where was accounted the number of counts viewed under the backscattering spectrum by the concrete. It is possible to determine the position and diameter of the steel rod into concrete, changing the parameters of detector collimator source, distance source-detector and type of concrete. Furthermore, it was shown that this same equipment can measure the density of the concrete. The applications of this equipment are used in the inspection works where it is necessary to make a non-destructive control of quality about the structure of building. (author). 7 refs., 46 tabs., 24 figs.

  10. Design and implementation of a quality assurance program for gamma cameras; Diseno e implementacion de un programa de aseguramiento de calidad para camaras gamma

    Energy Technology Data Exchange (ETDEWEB)

    Montoya M, A.; Rodriguez L, A. [Instituto Nacional de Cancerologia, Departamento de Medicina Nuclear, Av. San Fernando No. 22, Col. Seccion XVI, 14080 Mexico D. F. (Mexico); Trujillo Z, F. E., E-mail: montoya-moreno@hotmail.co [Hospital Regional de Alta Especialidad de Oaxaca, Area de Fisica Medica, Aldama s/n, Paraje El Tule, 71256 San Bartolo Coyotepec, Oaxaca (Mexico)

    2010-09-15

    In nuclear medicine more than 90% of the carried out procedures are diagnostic. To assure an appropriate diagnostic quality of the images and the doses optimization received by the patients originated in the radioactive material, it is indispensable the periodic surveillance of the operation and performance of the equipment s by means of quality assurance tests. This work presents a proposal of a quality assurance program for gamma cameras based on recommendations of the IAEA, the American Association of Medical Physics and the National Electrical Manufacturers Association. Some tests of the program were applied to an e.cam gamma camera (Siemens) of the Nuclear Medicine Department of the National Institute of Cancer. The intrinsic and extrinsic uniformity, the intrinsic spatial resolution and the extrinsic sensibility were verified. For intrinsic uniformity the average daily values of the integral uniformity and differential uniformity in the useful vision field were 2.61% and 1.58% respectively, the average monthly values of intrinsic uniformity for the integral and differential uniformity in the useful vision field were 4.10% and 1.66% respectively. The used acceptance criterions were respectively of 3.74% and 2.74%. The average values of extrinsic uniformity for the useful vision field were of 7.65% (intrinsic uniformity) and 2.69% (extrinsic uniformity), in this case the acceptance criterion is a value of 6.00%. The average value of intrinsic spatial resolution went 4.67 mm superior to 4.4. mm that is the acceptance limit. Finally, maximum variations of 1.8% were observed (minors than 2% that is the acceptance criterion) for the extrinsic sensibility measured in different regions of the detector. Significant variations of extrinsic sensibility were not observed among the monthly lectures. Of the realized measurements was concluded that the system requires of a maintenance service by part of the manufacturer, which one carries out later on to this work. The

  11. Technical Developments in the USAEC Process Radiation Development Program; Etudes technologiques dans le cadre du programme de mise au point d'applications industrielles des rayonnements de la CEA-EU; Issledovaniya v oblasti promyshlennogo primeneniya izluchenij, vkhodyashchie v programmu komissii po atomnoj ehnergii USAEC; Progresos tecnicos en el programa de la USAEC para el fomento de la irradiacion industrial

    Energy Technology Data Exchange (ETDEWEB)

    Machurek, J. E.; Stein, M. H. [Division of Isotopes Development, USAEC, Washington, DC (United States)

    1963-11-15

    autores comunican los resultados de catorce de esas investigaciones, resumiendo algunos en la monografia y dando mas detalles sobre otros en las actas respectivas. Los temas tratados son los siguientes: 1. Preparacion de combinaciones madera-materiales plasticos utilizando las radiaciones gamma para inducir la polimerizacion. 2. Empleo de las radiaciones beta emitidas por los productos de fision para la hidrogenacion del carbono y sus derivados con miras a la produccion de hidrocarburos liquidos combustibles. 3. Preparacion de semiconductores en los cuales las impurezas se distribuyen con arreglo a un esquema espacial predeterminado, con ayuda de transmutaciones neutronicas. 4. Polimerizacion radioinducida del etileno y sus copolimeroe. 5. Estudios basicos de los mecanismos y la cinetica de las reacciones radioinducidas. 6. Aspectos radioquimicos de la fluoracion de diversos compuestos aromaticos. 7. Empleo de monomeros polifuncionales para acrecentar la radiorreticulacion en el polietileno, el polipropileno, el poliisobutileno y el acetato de celulosa. 8. Efectos de la turgencia, tension y temperatura sobre las propiedades fisicas y quimicas de los polimeros producidos con ayuda de las radiaciones. 9. Influencia de los factores estructurales sobre las modificaciones radioinducidas en polimeros que conducen a la copolimerizacion por injerto. 10. Utilizacion de las radiaciones nucleares para modificar las propiedades de los materiales textiles. 11. Reacciones radioinducidas en las que se utiliza el cripton-85. 12. Preparacion de un ''Manual de Radiaciones''. 13. Empleo de enlaces organometalicos en la dosimetria de radiaciones gamma de elevada intensidad. 14. Preparacion de un dosimetro de celula solar. (author) [Russian] V sootvetstvii s programmoj issledovanij radiatsionnykh protsessov Komissii po atomnoj ehnergii SSHA byli provedeny obshirnye izyskaniya. Glavnaya tsel' ehtikh issledovanij sostoit v sodejstvii razrabotke tekhnologii, kotoraya obespechila by ehffektivnoe

  12. Quality assurance applied to Radiological Protection Program of CPHR - Centro de Proteccion Y Higiene de las Radiaciones; Aseguramiento de la calidad aplicado al programa de proteccion radiologica del CPHR - Centro de Proteccion y Higiene de las Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Marrero Garcia, M.; Jova Sed, L.; Domenech Nieves, H.; Hernandez Sainz, A. [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)

    2001-07-01

    The quality assurance in establishment that use ionizing radiation sources, is according to international recommendations of radiation protection programs. This work intends to present the experience of the Centro de Proteccion y Higiene de las Radiaciones (CPHR), in the implementation of requirements of quality in their Radiological Protection Program.

  13. Indium-Gallium Radiation Contour of the IRT Nuclear Reactor; Circuit d'activation d'indium-gallium dans le reacteur nucleaire IRT; Indij-gallievyj radiatsionnyj kontur yadernogo reaktora IRT; Circuito de radiaciones de indio-galio del reactor IRT

    Energy Technology Data Exchange (ETDEWEB)

    Breger, A K; Ryabukin, Y S; Tulkes, S G; Volkov, E N

    1960-07-15

    -industrielles. (author) [Spanish] Basandose en un trabajo teorico ya publicado, se preparo en el reactor IRT un circuito de radiaciones de indio-galio que constituye una nueva fuente de rayos gamma de elevada intensidad. El primer circuito de este tipo ''RK-1'' se construyo para el reactor IRT en el Instituto de Fisica de la Academia de Ciencias de la Republica Socialista Sovietica de Georgia. Este trabajo estudia los puntos siguientes: calculo de la activacion de la desintegracion del conjunto indio-galio; estructura del circuito RK-1 y su disposicion en el tanque del reactor y en la camara activa; dispositivo de admision de las sustancias liquidas y gaseosas en la zona de la irradiacion; transportador de las sustancias solidas sometidas a irradiacion. En el reactor IRT, cuya potencia es de 2 000 kW, la intensidad de irradiacion del circuito es igual a la de una fuente de radiacion gamma equivalente a 20 000 g de radio. En el trabajo se estudian las posibilidades de utilizacion de este circuito con fines semi-industriales y de investigacion. (author) [Russian] Osnovyvayas' na uzhe opublikovannoj teoreticheskoj rabote, byl podgotovlen indij-gallievyj radiatsionnyj kontur yadernogo reaktora IRT, kotoryj yavlyaetsya novym moshchnym istochnikom gamma-oblucheniya . Pervyj kontur ehtogo tipa RK-1 byl podgotovlen na reaktore IRT v Institute fiziki Akademii nauk Gruzinskoj SSR. V doklade dayutsya raschety aktivizatsij dlya indij-gallievogo splava, strukturnye kompanovki RK-1 i ikh raspolozhenie v bake reaktora i goryachej kamere, ustrojstvo podachi zhidkikh i gazoobraznykh veshchestv v zonu oblucheniya i konvejer dlya tverdykh veshchestv, kotorye podlezhat oblucheniyu. V reaktore IRT moshchnost'yu 2000 kW moshchnost' oblucheniya kontura ehkvivalentna moshchnosti oblucheniya gamma-izluchatelya, obladayushchego aktivnost'yu v 20000 g ehkv. radiya. V doklade obsuzhdayutsya perspektivy ispol'zovaniya indij-gallievogo radiatsionnogo kontura dlya issledovatel'skikh i polupromyshlennykh tselej

  14. Quality assurance applied to Radiological Protection Program of CPHR - Centro de Proteccion Y Higiene de las Radiaciones

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Jova Sed, L.; Domenech Nieves, H.; Hernandez Sainz, A.

    2001-01-01

    The quality assurance in establishment that use ionizing radiation sources, is according to international recommendations of radiation protection programs. This work intends to present the experience of the Centro de Proteccion y Higiene de las Radiaciones (CPHR), in the implementation of requirements of quality in their Radiological Protection Program

  15. Mensuration of equivalent dose with personal dosemeters and instruments of radiological protection in the new operative magnitudes ICRU, for external fields of beta radiation. Part I. Study of the homogeneity of the response personal dosemeters leaves (cards G-1, TLD-100), in radiation fields of Co{sub 60}; Medicion de dosis equivalente con dosimetros personales e instrumentos de proteccion radiologica en las nuevas magnitudes operativas ICRU, para campos de radiacion beta externos. Parte I. Estudio de la homogeneidad de la respuesta dosimetros personales (tarjetas G-1, TLD-100), en campos de radiacion de Co{sub 60}

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J.T. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1994-01-15

    A sample of 40 composed personal dosemeters by cards model: G-l, (each card is made up of two TLD-100 crystals encapsulated in teflon), Harshaw trademark; those personal dosemeters present a free window and another with a filter of A1 of 171.7 mg cm{sup -2} of mass thickness.The objective of the work is to select of this sample of 40 personal dosemeters a population with the same stocking and standard deviation. The technique used is that of comparison of stockings, (ANOVA; Variance Analysis, when samples of the same one were had size; and/or GLM, Widespread Lineal Models, when the samples were of different size), by means of the use of those Duncan statistics, SNK, Tukey, Gabriel; the results are validated proving the kindness of adjustment of the experimental data to a Normal distribution by means of the Shapiro-Wilks statistics.The experimental design used consists on a test of two vias: a via is the variable card with two levels, (crystal 1 and 2), the other via is the variable irradiation position with four levels, (LS=left superior, SR= right superior, LI= left Inferior, IR = right inferior). The irradiations carried out in blocks of four personal dosemeters in a gamma radiation beam range of Cobalt 60; carrying out three repetitions of the design. With object of proving the homogeneity of the filter of A1 in those personal dosemeters the experimental design was executed for those cards without personal dosemeters.They were also carried out tests of stockings to the readings of bottom and sensibility of the reader equipment, (Harshaw, model marks 2271), certain that doesn{sup t} exist differences for sequence of reading, but if in the stockings of the sensibility, (they were 4 different populations). The responses of the dosemeters were corrected subtracting him the reading correspondence of bottom and by sensibility of the reader equipment before subjecting them to the tests of stockings mentioned. Of the results of the tests of stockings for the cards with

  16. Critical Consideration of the Methods of Calculation Used in the Evaluation of the Absorbed Dose to the Skin in Cases of External Contamination; Observations Critiques sur les Methodes de Calcul Utilisees pour l'Evaluacion de la Dose Absorbee par la Peau en Cas de Contamination Externe; 041a 0420 0414 ; Observaciones Criticas Sobre los Metodos de Calculo Utilizados para Evaluar la Dosis Absorbida por la Piel en Caso de Contaminacion Externa

    Energy Technology Data Exchange (ETDEWEB)

    Casnati, E.; Breuer, F. [Gruppo di Dosimetria e Standardizzazione, CNEN, Centro di Studi Nucleari della Casaccia, Rome (Italy)

    1965-06-15

    resultats permettent de conclure que, dans la geometrie consideree, on peut determiner par des formules de type exponentielle, d'une part la dose imputable aux rayons beta et, d'autre part, la dose imputable aux rayons gamma pour la couche basale de la peau;- on peut considerer les resultats comme acceptables du point de vue de la radioprotection. (author) [Spanish] La dosis absorbida, suele calcularse mediante la formula de Loevinger cuando se trate de particulas beta mientras que para las radiaciones electromagneticas se recurre habitualmente a una formula exponencial. En la memoria, los autores se proponen examinar si en el caso de contaminacion cutanea puede considerarse satisfactorio el empleo de una formula exponencial (la formula de Rossi y Ellis) y de una formula similar para calcular la dosis beta y la dosis gamma, respectivamente. Con este objeto, se han comparado los resultados.obtenidos para este tipo especial de geometria por medio de la formula de Rossi y Ellis y con la formula de Loevinger para partfculas beta; por lo que respecta a la radiacion gamma, se han comparado los valores obtenidos mediante la formula exponencial y con otras dos formulas mas complejas, que se ajustan a las condiciones de acumulacion fotonica maxima nula, respectivamente. Estos resultados permiten sacar la conclusion de que, dadas las condiciones geometricas de que se trata, pueden determinarse mediante la formula de tipo exponencial tanto la dosis de radiacion beta como la dosis de radiacion gamma en la dermis. Los resultados son aceptables desde el punto de vista de la proteccion radiologica. (author) [Russian] Obychno pri podschete dozy ispol'zuetsja formula Laevingera dlja chastic i jeksponencial'naja formula dlja jelektromagnitnyh izluchenij. V doklade rassmatrivaetsja vopros o tom, mozhno li schitat' udovletvoritel'nym ispol'zovanie jeksponencial'noj formuly (podobnoj formule Rossi i Jellisa) i analogichnyh formul pri podschete sootvetstvenno beta- i gamma-dozy. S jetoj cel

  17. Effect of the gamma radiation in hydrotalcite with chromates; Efecto de la Radiacion Gamma en Hidrotalcitas con Cromatos

    Energy Technology Data Exchange (ETDEWEB)

    Martinez G, S. [Facultad de Ciencias, Universidad Autonoma del Estado de Mexico, Instituto Literario No. 100 Col. Centro, 50000 Toluca, Estado de Mexico (Mexico); Bulbulian, S. [ININ, Carr. Mexico-Toluca Km. 36.5, 52045 Ocoyoacac, Estado de Mexico (Mexico)]. e-mail: soniakorn@yahoo.com

    2004-07-01

    At the moment the generation of radioactive wastes is topic of numerous studies. In this work was retained anionic material, chromates, in hydrotalcite that are anionic exchangers. It was proposed to warm the HT at different temperatures of 600 C up to 1200 C with the purpose of immobilizing the chromium inside the hydrotalcite. To high temperatures (1000 and 1200 C) it was formed one spinel (MgCr{sub 2}O{sub 4}) that is a very stable compound. It was found that when increasing the heating temperature, the anions are retained strongly. The immobilization of the Cr was determined through the chromium lixiviation with solutions 1N and 5N of NaCl. Also it was studied the effect of the radiation on the heated materials. The radiation dose used for it was of 1000 and 6000 kGy. The results show that for the calcined samples at 1000 and 1200 C irradiated or no irradiated, the chromium is strongly retained in form of spinels that is the structure formed after the calcination of the material. (Author)

  18. Development of a gamma dosimeter using a photodiode; Desenvolvimento de um dosimetro para radiacao gama utilizando fotodiodo

    Energy Technology Data Exchange (ETDEWEB)

    Melo, F.A. de

    1988-05-01

    In the last years, the application of semiconductor detectors in radiation spectroscopy and dosimetry has increased. Silicon diodes have found utility in radiation dosimetry principally because a diode produces a current approximately 18000 times larger than of an ionization chamber of an equal sensitive volume. As the characteristics of the semiconductor detectors are the same as the common photodiode, a gamma dosimeter using this type of electronic component was developed. The photodiode SFH206 operating in photovoltaic mode was used. An electrometric unit was constructed to measure the current generated in this detector. The results obtained showed: the response of the photodiode was linear with the dose and that variation of 40 degrees in the incidence angle of the radiation caused a variation of 5% in the dose determination; the response reproducibility of the photodiode was studied, and the results showed that the variation coefficient is smaller than 0,02%; the small dimension of the silicon photodiode recommend its use as a gamma dosimeter for medical applications. (author). 19 refs, 32 figs, 1 tab.

  19. Application of gamma irradiation technique for the preservation of propolis; Aplicacao da tecnica de irradiacao gama para preservacao de propolis

    Energy Technology Data Exchange (ETDEWEB)

    Matsuda, Andrea Harumi

    2002-07-01

    Irradiation has been recognized as an efficient method for the reduction of deteriorating and pathogenic microorganisms in foods. Propolis is a resinous product made by bees from material processed by the bee's own metabolism and resins from plants. The aim of this work was the application of gamma irradiation technique for the preservation of propolis, because of its efficiency in the reduction of the microbial load. The changes on the total flavonoids content, phenolic compounds and other characteristics required for the qualification and characterization of Brazilian propolis were also analysed. Propolis samples from Juiz de Fora region, Minas Gerais, were irradiated in a {sup 60}Co source, with doses from 0 to 10kGy for the microbiological analyses and 5.0, 7.0 and 10.0kGy for the physico-chemical analyses. The physico-chemical that have been made were: determination of total flavonoids content, semi-quantitative determination of phenolic compounds (artepelin-C, kempferol, chrysin, galangin and quercetin), dry matter analysis, humidity, ash content, mechanical mass and waxes. The ionizing radiation has shown to be efficient in the reduction of the microbial load. Total coliforms determination showed a great reduction with the dose of 3kGy and concerning mesophile aerobic bacteria a systematic reduction was observed, achieving values <10 UFC/g for the dose of 10kGy; similar results was obtained for molds and yeasts. Salmonella assays were negative for all samples. There was no significant alteration on total flavonoids contents nor on the composition of phenolic compounds as a consequence of radiation application at the assayed conditions. The complementary analyses of dry matter and humidity contents, ashes, mechanical mass and waxes did not shown changes after irradiation even with the maximum dose of 10kGy, remaining the results within the standards required by the Brazilian legislation. (author)

  20. Normas básicas de seguridad durante el manejo de equipos de radiaciones no ionizantes Safety basic rules when handling non-ionizing radiation equipment

    Directory of Open Access Journals (Sweden)

    Rosa María Armida Bretones

    2012-03-01

    Full Text Available La preocupación creciente de los trabajadores hacia los posibles efectos nocivos de la exposición a campos electromagnéticos, está suponiendo una percepción desproporcionada de los riesgos derivados de la exposición. En la actualidad, no existe evidencia científica sobre dichos efectos nocivos, siendo aconsejable la vigilancia sobre las exposiciones que están fuera de los límites de seguridad. Desde este Servicio de Prevención y en colaboración con el Servicio de Física Médica, hemos elaborado un procedimiento que garantice, mediante criterios preventivos básicos, la seguridad y salud de los trabajadores que manejan equipos emisores de radiaciones no ionizantes, en nuestro hospital y centros de especialidades. Para la elaboración de este procedimiento hemos revisado la literatura científica relativa a los efectos de los campos electromagnéticos sobre la salud, reuniones periódicas de trabajo entre ambos servicios, identificación y ubicación de los equipos de radiaciones no ionizantes, y asesoramiento por expertos en la materia. El procedimiento establece medidas de control para los trabajadores, y medidas de control para los equipos. Con la finalidad de conseguir una buena difusión e implantación de dicho procedimiento, hemos elaborado dípticos y carteles, donde reflejamos las medidas de control para trabajadores y equipos: Onda Corta, Microondas, Magnetoterapia, Resonancia Magnética Nuclear, Láser y Ultravioleta El procedimiento con sus carteles explicativos ha sido distribuido específicamente por servicios, realizando formación e información de los trabajadores que maneja dichos equipos.Employee increasing concern about possible dangerous effects of the exposure to electromagnetic fields is meaning a distorted perception of the exposure related risks. Currently, there is no scientific evidence of the dangerous effects mentioned although surveillance over the exposures out of the safety limits is recommended. Within

  1. Análisis y diseño de un detector compacto de radiación gamma de estado sólido para espectrometría

    OpenAIRE

    Toral Zamorano, Francisco Javier

    2017-01-01

    La detección de radiación es una necesidad desde el momento del descubrimiento de la radiación misma. Son muchas las tecnologías actuales empleadas para medir el nivel de radiación: contadores proporcionales, Geiger-Müller, cámaras de ionización, centelleo con tubos fotomultiplicadores, centelleo líquido, detectores de germanio, detectores de semiconductor de estado sólido (con o sin centelleador)… De todos ellos, solamente unos pocos son válidos para realizar una espectrometría gamma. Mie...

  2. Construction and Operation of a Commercial Gamma-Ray Package-Sterilizing Plant; Construction et fonctionnement d'une installation industrielle pour la sterilisation d'articles sous emballage par les rayons gamma; Razrabotka i ehkspluatatsiya sbornoj ustanovki gamma-izlucheniya promyshlennogo tipa dlya sterilizatsii meditsinskikh materialov; Construccion y funcionamiento de una instalacion industrial para la esterilizacion gamma de articulos medicos empaquetados

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. G. [Johnson' s Ethical Plastics Ltd., Slough (United Kingdom)

    1963-11-15

    'installation dans une unite d e production exploitee par une entreprise commerciale et la bacteriologie. Il etudie brievement la rentabilite de la sterilisation par les rayons gamma et examine quelles sont les autres possibilites d'utilisation d'une installation de cette nature. (author) [Spanish] En la memoria se describe una instalacion de esterilizacion a base de {sup 60}Co, explotada comercialmente por la Johnson's Ethical Plastics Limited en Slough (Reino Unido). Se trata de una instalacion de tratamiento continuo totalmente automatica equipada con una fuente de 72 000 c. Aprovechando la experiencia adquirida por la Junta de Energfa Atomica del Reino Unido en su Package Irradiation Plant de Wantage, dicha instalacion fue concebida para esterilizar jeringas de material plastico y otros articulos medicos no recuperables de analoga densidad aparente. La instalacion viene funcionando desde noviembre de 1962. En la memoria se indican las principales caracteristicas de construccion, en especial los dispositivos para la seguridad del personal, y el metodo de carga de las varillas de cobalto. Se describe la experiencia adquirida, en particular en lo que atauee a la dosimetria, la integracion de la instalacion en el proceso productivo de una empresa comercial y los resultados bacteriologicos. Por ultimo, se examinan brevemente los aspectos economicos de la esterilizacion por irradiacion gamma y se evaluan las posibles aplicaciones de una instalacion de este tipo en el futuro. (author) [Russian] Tsel' nastoyashchej stat'i - opisanie ustanovki dlya oblucheniya s pomoshch'yu Co{sup 60}, na kotoroj v nastoyashchee vremya proizvoditsya v promyshlennykh masshtabakh sterilizatsiya meditsinskikh materialov (firma ''Dzhonsons ehtikal plastike'' v Slou, Angliya). Ustanovka nepreryvnogo dejstviya snabzhena istochnikom v 72 000 kyuri; vse operatsii polnost'yu avtomatizirovany. Na osnove opyta, poluchennogo v ehtoj oblasti pri ehkspluatatsii sbornoj radiatsionnoj ustanovki v Uontidzhe (pri

  3. Design of a versatile detector for the detection of charged particles, neutrons and gamma rays. Neutron interaction with the matter; Diseno de un detector versatil para la deteccion de particulas cargadas, neutrones y rayos gamma. Interaccion neutronica con la materia

    Energy Technology Data Exchange (ETDEWEB)

    Perez P, J J [Comision Nacional de Seguridad Nuclear y Salvaguardias, Mexico, D.F. (Mexico)

    1991-07-01

    The Fostron detector detects charged particles, neutrons and gamma rays with a reasonable discrimination power. Because the typical detectors for neutrons present a great uncertainty in the detection, this work was focused mainly to the neutron detection in presence of gamma radiation. Also there are mentioned the advantages and disadvantages of the Fostron detector.

  4. Ultraviolet radiation response of two heterotropy Antarctic marine bacterial; Respuesta a la radiacion ultravioleta de dos cepas bacterianas marinas heterotrofas antarticas

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Edgardo A [Buenos Aires Univ. (Argentina). Facultad de Farmacia y Bioquimica; Ferreyra, Gustavo A; Mac Cormack, Walter P [Direccion Nacional del Antartico, Buenos Aires (Argentina). Instituto Antartico Argentino

    2004-07-01

    Two Antarctic marine bacterial strains, were exposed to different irradiance of ultraviolet (UV) solar radiation using several experimental protocols and interferential filters. Results showed that both, UV-A and UV-B radiation produce deleterious effects on two tested bacterial strains. The mortality values under UVB treatments were higher than those observed under UVA treatments. UVvi strain proved to be more resistant to UV radiation than the UVps strain. (author) [Spanish] Dos cepas marinas antarticas fueron expuestas a diferentes irradiancias de radiacion solar ultravioleta (UV) utilizando diferentes protocolos experimentales y filtros interferenciales. Los resultados mostraron que tanto la radiacion UV-A como UV-B produce efectos deletereos sobre las dos cepas bacterianas analizadas. Los valores de mortalidad bajo tratamiento UV-B fueron mayores que los observados bajo tratamiento UV-A. La cepa UVvi mostro mayor resistencia a la radiacion UV que la cepa UVps. (autor)

  5. Two New Types of Detector for X- or Gamma-Ray Cameras; Deux Nouveaux Types de Detecteurs pour Camera a Rayons X ou {gamma}; O dvukh novykh tipov detektorov dlya rentgenovskikh ili gamma-kamer; Dos Nuevos Tipos de Detector para Camaras de Rayos X o Gamma

    Energy Technology Data Exchange (ETDEWEB)

    Kellershohn, C.; Desgrez, A. [Departement de Biologie, Service Hospitalier Frederic Joliot (France); Lansiart, A. [Departement d' Electronique, Centre d' Etudes Nucleaires de Saclay (France)

    1964-10-15

    Electric Valve, que actua como obturador. Una parte de la luz que penetra en el dispositivo optico es recibida por un fotomultiplicador que rige la apertura del tubo obturador por mediacion de un selector de amplitudes. Este artificio permite efectuar la seleccion entre la luz debida a la senal y la debida al ruido del tubo de Thomson. Solo la primera ocasiona La apertura del tubo obturador. Como la duracion de dicha apertura es sumamente corta, el cociente senal/ruido de este conjunto detector es suficientemente alto para obtener una imagen de la pantalla terminal del tubo obturador por medio de un aparato fotografico abierto constantemente. En la memoria se discuten las caracteristicas de esos dos tipos de detector y los primeros resultados obtenidos. (author) [Russian] Kamery dlja ren t genovskih ili gamma-luchejsozd aju t sja glavnym o br a zom na osnove sovmeshhennogo s detektorom stenopirovannogo ili s etch atogo opticheskogo ustrojstv a. Avtory predlagajut dva tipa detektorov, polnost'ju otlichajushhihsja ot pribora A n g era, kotoryj do p o sl edn e go vremeni byl edinstvennym priborom tak o goroda. Pervyj p redstavlja et soboj kameru s samovoznikajushhej scintilljaciej. Jeta kamera, 2 0 sm v diametre i zapolnennaja redkim g a zom (argonom ili ksenonom), predstavljaet soboj katod i dve s etk i . Katod i vtoraja s etk a nahodjatsja pod raznost'ju potenciala v neskol'ko kilovol't, nemnogo nizhe probojnogo naprjazhenija. Pervoe prostranstvo mezh du k atodom i s etk oj sluzhit istochnikom jel ek tr on ov , p oluchaemyh pod vozdejs tv i em ren t genovskih ili gamma-fotono v slaboj jen er gi i . Mozhno takzhe ispol'zovat' naklejku na katodizmetalla s povyshennym chislom Z, libo kristallicheskij scintilljator, sovmeshhennyj s fotokatodom. Rezk i j vybros zarjadov v rezul' tat e razmnozhenija jelektronov v lavine Taunsenda privodit posle sootvetstvujushhego usilenija k chetko lokalizovannoj scintilljacii s opozdaniem v kak ujuto doljumksek. Izobrazhenie p oluchaet sja s

  6. Some Problems of Calculation and Design of High-Activity Gamma Units; Quelques aspects du calcul et de l'etablissement de projets d'installations puissantes emettrices de rayonnement gamma; Nekotorye voprosy rascheta i proektirovaniya moshchnykh gamma-ustanovok; Algunos aspectos del calculo y construccion de instalaciones de irradiacion gamma de elevada intensidad

    Energy Technology Data Exchange (ETDEWEB)

    Bibergal, A V; Leshchinsky, N I; Margulis, U Ya; Khrushev, V G [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialist Republics (Russian Federation)

    1960-07-15

    installations et reduisant le cout de la construction et de l'exploitation. (author) [Spanish] En este informe se indican los requisitos esenciales que deben reunir las instalaciones de irradiacion gamma destinadas a distintos usos. Se describen varios metodos para calcular campos de distintas intensidades en funcion de la forma de la fuente de cobalto-60 y cesio-137 empleada y se facilitan graficos, nomogramas y formulas que permiten determinar el valor de la dosis de rayos gamma absorbida por el objeto irradiado. Algunos de los datos calculados se han confirmado experimentalmente. Se examinan los usos mas convenientes de una serie de dispositivos de irradiacion de distintas configuraciones en instalaciones experimentales e industriales. Los autores estudian asimismo los procedimientos de irradiacion de diferentes muestras, que se aplican con el proposito de poder elegir unas condiciones de irradiacion optimas (coeficiente de aprovechamient o de la radiacion, uniformidad del campo de irradiacion, etc.), La memoria describe tambien algunos sistemas racionales de proteccion que simplifican las operaciones de irradiacion, asi como los dispositivos que permiten cambiar la carga y reducir de este modo los costos de construccion y de explotacion de las instalaciones. (author) [Russian] V doklade sformulirovan y osnovnye trebovaniya, pred{sup y}avlyaemye k gamma-ustanovkam razlichnogo naznacheniya. Provodyatsya nekotorye metody rascheta doznykh polej dlya razlichnykh form obluchatelej, a takzhe grafiki, nomogrammy i formuly, pozvolyayushchie poluchit' znacheniya pogloshchennoj dozy gamma-luchej kobal'ta-60 i tseziya-137 v obluchaemom ob{sup e}kte. Nekotorye raschetnye dannye podtverzhdayutsya ehksperimentami. Rassmatrivaets ya tselesoobraznost ' ispol'zovani ya obluchatelej razlichnykh konfiguratsij , primenyaemykh v ehksperimental'nykh i proizvodstvennykh ustanovkakh. Obsuzhdaetsya tekhnologiya oblucheniya razlichnykh ob{sup e}ktov s tsel'yu vybora optimal'nykh uslovij

  7. Cobalt-60 and Caesium-137 Gamma Sources; Sources de rayonnement gamma au cobalt-60 et au cesium-137; Gamma-istochniki iz kobal'ta-605 i tseziya-137; Fuentes gamma de cobalto-60 y de cesio-137

    Energy Technology Data Exchange (ETDEWEB)

    Kulish, E E; Fradkin, G M [Academy of Sciences of the USSR, Moscow, Union of Soviet Socialits Republics (Russian Federation)

    1960-07-15

    cobalto-60 y cesio-137 producidas en la Union Sovietica y se examinan algunos problemas de orden tecnologico planteados por su fabricacion. En el informe figuran una serie de datos sobre las propiedades de las radiaciones emitidas por las fuentes de {sup 60}Co y {sup 137}Cs y del material con que estas se fabrican. Se facilitan informaciones sobre la influencia que la magnitud del flujo neutronico y las caracteristicas geometricas de la muestra ejercen sobre la actividad de la fuente; el informe tambien contiene datos sobre el rendimiento de los distintos isotopos de cesio obtenidos por fision de los nucleos de uranio. Se examinan los procedimientos para encerrar hermeticament e las fuentes y se facilita una lista completa de las fuentes utilizadas en la Union Sovietica, con indicacion de sus caracteristicas geometricas y de su actividad. Por ultimo, se hace un estudio comparativo de las fuentes de {sup 60}Co y {sup 137}Cs. (author) [Russian] V doklade privodyatsya osnovnye tekhnicheskie kharakteristiki vypuska- emykh v SSSR gamma-istochnikov na osnove kobal'ta-60 i tseziya-137, a takzhe rassmatrivayutsya nekotorye voprosy tekhnologii ikh proizvodstva. Doklad soderzhit svedeniya o sostave izlucheniya izotopov Co{sup 60} i Cs{sup 137} i syr'ya, iz kotorogo oni izgotavlivayutsya . Privodyatsya dannye o zavisimosti aktivnosti kobal'tovykh istochnikov ot velichiny potoka nejtronov i geometricheskikh razmerov obraztsa, a takzhe dannye o velichine vykhoda izotopov tseziya pri delenii yader urana. Dalee rassmatrivaetsya vopros o germetizatsii istochnikov i privoditsya polnaya nomenklatura vypuskaemykh v SSSR istochnikov s ukazaniem ikh geometricheskikh razmerov i velichiny aktivnosti. V kontse provoditsya nekotoroe sravnenie istochnikov Co{sup 60} i Cs{sup 137}. (author)

  8. Characterization by Monte Carlo of the dose after a glass shield lead for gamma ray; Caracterizacion por Monte Carlo de la dosis tras un blindaje de vidrio de plomo para rayos gamma

    Energy Technology Data Exchange (ETDEWEB)

    Esteve Sanchez, S.; Gil Conde, M.; Contreras Gonzalez, J. L.; Rosado, J.; Pazyi, V.

    2013-07-01

    When a gamma-ray beam crosses the border between two media characterized by atomic number very different is they produce effects on the distribution of doses near the border difficult to predict with simple models. The case of rays gamma affecting a lead glass is particularly interesting for its application to shielding of common use. interested in studying the importance of the residual dose after the shield. (Author)

  9. Utilidad de los ensayos de liberación de interferón gamma para la detección de tuberculosis en población pediátrica

    Directory of Open Access Journals (Sweden)

    Gerardo Álvarez-Hernández

    2015-11-01

    Full Text Available El ensayo de liberación de interferón gamma es un método novedoso para el diagnóstico de la tuberculosis aunque su utilidad es incierta en población pediátrica. Objetivo: examinar la utilidad diagnóstica del QuantiFERON-TB Gold (QFT-G®, uno de los ensayos de liberación de interferón gamma comerciales, en población pediátrica del Estado de Sonora, México. Materiales y métodos: estudio transversal con 160 menores de 19 años de edad, en un hospital de Sonora, México. Se compararon tres grupos, uno de pacientes con tuberculosis activa, otro con tuberculosis latente y uno más de controles hospitalizados. Los criterios de Stegen-Toledo fueron el estándar empleado. Se usó regresión logística multivariada para evaluar la asociación entre el QFT-G® y los predictores seleccionados. Resultados: la sensibilidad del QFT-G® en la tuberculosis activa fue de 76.9% y la especificidad de 90.3%. Para la tuberculosis latente la sensibilidad fue 25.0% y la especificidad de 98.6%. El QFT-G® mostró una concordancia moderada (K = 0.574 con el estándar. También mostró asociación con la radiografía de tórax sugestiva de tuberculosis (razón de momios ajustada 4.37, IC 95%: 1.42, 13.42 y con el hecho de ser caso de tuberculosis pulmonar (razón de momios ajustada 6.15, IC 95%: 1.90, 19.92. Conclusión: el ensayo de liberación de interferón gamma es un método útil para diagnosticar tuberculosis activa y puede emplearse para descartar tuberculosis latente en población pediátrica.

  10. Radiation: Rational use of diagnostic imaging studies in pediatrics; Radiaciones: uso racional de los estudios de diagnósticos por imágenes en pediatría

    Energy Technology Data Exchange (ETDEWEB)

    Gentile, Fernando [Hospital Ricardo Gutierrez, Buenos Aires (Argentina)

    2008-07-01

    The objectives of this paper are to recognize the biological effects of radiation; explain the action of ionizing radiation on the cell; list the main sources of ionizing radiation; to indicate imaging studies considering the danger of radiation; select the method of imaging saving radiation; rational use of imaging studies without repeating exams. [Spanish] Los objetivos de este documento son: reconocer los efectos biológicos de las radiaciones; explicar la acción de las radiaciones ionizantes sobre la célula; enumerar las principales fuentes de radiaciones ionizantes; indicar estudios por imágenes teniendo en cuenta el peligro de las radiaciones; seleccionar el método de estudio por imágenes que ahorra radiación; hacer un uso racional de los estudios por imágenes evitando repetir exámenes.

  11. Effects of Variable Dose-Rates on Radiation Damage in the Rust-Red Flour Beetle, Tribolium Castaneum Herbst; Effets du debit de dose sur les dommages radioinduits chez le tenebrion roux (Tribolium Castaneum Herbst); Vliyanie razlichnykh moshchnostej doz na radiatsionnoe povrezhdenie krasnogo muchnogo zhuka, Tribolium Castaneum (Herbst); Radio lesiones que sufre el Tribolium Castaneum Herbst cuando se le somete a dosis de radiaciones de diversas intensidades

    Energy Technology Data Exchange (ETDEWEB)

    Nair, K. K.; Subramanyam, G. [Biology Division, Atomic Energy Establishment, Trombay, Bombay (India)

    1963-09-15

    In order to find out whether a change in dose-rate would significantly alter a radiation response, eggs as well as the adults of Tribolium castaneum were tested for viability and fertility respectively after exposure to gamma radiation at different dose-rates. The doses employed were 2000 and 5000 rad and the dose-rates ranged from 126 rad/h to 140 000 rad/h. It was observed that with an increase in dose-rate there was a decline in the fertility of the adults. Similarly the viability of the eggs was considerably reduced as the dose-rate increased, but at very high dose-rates there was a significant increase in viability. The significance of these findings is discussed. (author) [French] En vue de determiner si une variation du debit de dose modifie de maniere significative la reponse aux rayonnements, on a fait des essais sur des oeufs et des adultes de Tribolium castaneum, dont on a etudie respectivement la viabilite et la fecondite apres exposition a des doses de rayons gamma d'intensites differentes. On a administre des doses de 2000 et 5000 rad, le debit de dose variant de 126 a 140 000 rad/h. On a constate que la fecondite des adultes diminuait a mesure que le debit de dose augmentait. De meme, la viabilite des oeufs etait considerablement reduite a mesure que le debit de dose augmentait, mais pour des debits de dose tres eleves la viabilite augmentait sensiblement. Les auteurs analysent les donnees obtenues. (author) [Spanish] Para averiguar si un cambio en la intensidad de la dosis produce alteraciones fundamentales en la radiosensibilidad, se comprobo la viabilidad de los huevecillos y la fertilidad de los adultos de Tribolium castaneum despues de exponerlos a dosis de radiaciones gamma de intensidad diferente. Las dosis empleadas fueron 2000 y 5000 rad, y las intensidades oscilaron entre 126 rad/h y 140 000 rad/h. Al aumentar la intensidad de la dosis se produce una disminucion de la fertilidad de los adultos. De modo similar, la viabilidad de los

  12. Relative Biological Effectiveness of 14-MeV Fast Neutrons to Co{sup 60} Gamma-Rays in Einkorn Wheat; Efficacite Biologique Relative des Neutrons Rapides de 14 MeV par Rapport aux Rayons Gamma de {sup 60}Co sur l'Engrain; Otnositel'naya biologicheskaya ehffektivnost' bystrykh nejtronov s ehnergiej 14 MeV i gamma-luchej CO{sup 60} pri ikh dejstvii na pshenitsu odnozernyanku; EBR de los Neutrones Rapidos de 14 MeV y de los Rayos Gamma del {sup 60}Co en el Trigo Escanda Menor

    Energy Technology Data Exchange (ETDEWEB)

    Fujii, T. [National Institute of Genetics, Misima (Japan)

    1964-05-15

    , sobrevivio entre 60 y 80% de las plantulas y en los grupos tratados con rayos gamma, la supervivencia fue del 100%. En cambio, en el grupo sometido a la irradiacion neutronica con la dosis mas elevada, solo sobrevivio un 4% de las plantulas. No se observaron mutaciones en el grupo testigo y el numero de plantas que presentaba retonos rayados crecio al aumentar la dosis de ambos tipos de radiacion. Se observaron retoflos con mutaciones en un 15% de las plantas sobrevivientes tratadas con la dosis inferior de neutrones y la misma frecuencia se registro para la dceis mayor de rayos gamma. Al parecer, la EBR de los neutrones de 14 MeV con respecto a los rayos gamma de {sup 60}Co, para la mutacion somatica, es 20 como minimo. (author) [Russian] Avtor izuchal OBJe nejtronov s jenergiej 14 Mjev i gamma-luchej Sobo pri ih dejstvii na pshenicu odnozernjanku s pomoshh'ju special'nogo lokusnogo metoda. Dlja opyta ispol'zovalis' semena generacii F{sub 1} gibrida mezhdu ishodnym sortom i mutantom Chlorina (mutant Chlorina byl poluchen kak edinstvennyj recessivnyj rentgenomutant; ot stadii sejanca do nastuplenija spelosti on byl odnorodno svetlozelenym s otnositel'no vysokoj vyzhivaemost'ju i urozhajnost'ju). U rastenij F{sub 1} byla normal'naja zelenaja okraska i normal'nyj harakter rosta. Pokojashhiesja semena Ft obluchali bystrymi nejtronami v dozah 0,5, 1,0 i 1,4 krad i gamma-luchami v dozah 4,3 8,6 i 12,9 krad. Mutacii ot dominantnyh normal'nyh zelenyh do Chlorina nabljudalis' posle oboih vidov obluchenija i pojavljalis' v list'jah i stebljah geterozigotnyh rastenij X{sub 1} v vide prodol'nyh polos. Okolo 80% semjan vzoshlo na kontrol'nyh uchastkah i na uchastkah posle obluchenija ca- mymi nizkimi dozami nejtronov i gamma-luchej, procent vshozhesti postepenno snizhalsja s povysheniem dozy pri oboih vidah obluchenija. Krome togo, takaja zhe tendencija nabljudalas' i na rannih stadijah rosta sejancev, kotoryj postepenno tormozilsja s povysheniem dozy. Soglasno jetim dannym nejtronnoe

  13. High-Dose Ionizing Radiation Photographic Dosimetry; Mesure, par des Methodes Photogra Phiques, de Doses Elevees de Rayonnements Ionisants; 0424 041e 0422 041e 0413 0420 0414 ; Dosimetria Fotografica de Dosis Elevadas de Radiaciones Ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Trousil, J.; Bucina, I. [Institute for Research Production and Application of Radioisotopes Prague, Czechoslovakia (Czech Republic)

    1965-06-15

    ionizantes comprendidas entre 10 mr y 1000 r (para rayos gamma y rayos X de elevada energia). Con arreglo a este metodo, se utilizan dos peliculas con emulsiones diferentes, montadas en el mismo estuche. El metodo se caracteriza esencialmente por el hecho de que permite evaluar dosis comprendidas entre los limites indicados, sin necesidad de saber si se produjo una exposicion a dosis mas elevadas, con un margen de error inferior a {+-}25 en todo el intervalo (limite de seguridad 95%); ademas permite determinar con una precision satisfactoria la energia de las radiaciones a que la pelicula estuvo expuesta. Se examinan los aparatos, peliculas y tratamiento quimicos necesarios para esas mediciones. Se explica el principio de construccion de un densitometro que permite medir el ennegrecimiento de la pelicula con una precision constante en el intervalo comprendido entre D = 0 y D = 6. De este modo es posible aprovechar toda la zona de ennegrecimiento de la pelicula correspondiente a dicho intervalo. Como no se utiliza iotomultiplicador, los riesgos de iluminacion excesiva se reducen al minimo, por lo que el aparato resulta apropiado para mediciones corrientes. Ademas se indican los parametros que han de satisfacer las peliculas dosimetricas para poder detectar dosis elevadas, y se comparan las caracteristicas de las peliculas dosimetricas FOMA y ORWO en lo que respecta a la medicion de dosis elevadas. Con un progreso en la dosimetria de dosis elevadas, cabe mencionar el metodo de revelado retardado que se describe con detalle, con arreglo al cual se anaden al revelador compuestos del tipo nitrobenzimidazol y benzotriazol, en concentracion adecuada. En el caso de emulsiones lentas con elevado contenido de plata, esta tecnica permite medir exposiciones de dosis gamma (rayos X de elevada energia) de hasta 10{sup 3}r, o aun mayores, si no es menester una evaluacion precisa en un intervalo de hasta 100 r. Se describe el efecto retardador de los productos quimicos anadidos al revelador

  14. The Main Technological Characteristics of Apparatus for Industrial Radiochemical Processes, in Particular Ethylene Polymerization; Caracteristique techniques fondamentals des appareils pour l'application industrielle de reactions chimiques sous rayonnement (notamment la polymerisation de l'ethylene ); Osnovnye tekhnologicheskie kharakteristiki apparatov dlya provedeniya radiatsionno-khimi-cheskikh protsessov (v chastnosti, dlya polimerizatsii ehtilena) v promyshlennom masshtabe; Principales caracteristicas tecnologicas de los aparatos para la aplicacion industrial de reacciones radioquimicas

    Energy Technology Data Exchange (ETDEWEB)

    Syrkus, N P; Breger, A K; Weinstein, B I [Karpov Physicochemical Institute, Moscow, USSR (Russian Federation)

    1960-07-15

    , Q {approx} W{sub 0}{sup 0'5}. (author) [Spanish] Se propone un metodo de evaluacion de la efectividad de los aparatos, cualquiera que sea su construccion, comparandola con la productividad de un aparato infinitamente grande que tenga la misma fuente de radiaciones. Se indican las caracteristicas tecnologicas de un aparato destinado a la polimerizacion del etileno mediante radiaciones (a presion de 200 atmosferas y temperatura de 25{sup o} C{sup 4} empleando como fuente principal radiaciones gamma de cobalto-60 a distintas actividades. Se pueden calcular los datos tecnicos de tal aparato segun el valor medio de la intensidad de las dosis, fijado segun la magnitud del coeficiente de rendimiento energetico del aparato. Se indica en el trabajo que, siendo las demas condiciones iguales, la productividad (Q) del aparato es funcion exponencial de la intensidad (W{sub 0}) de las radiaciones gamma del mismo. Para el aparato que se estudia en el trabajo la formula es: Q{approx}W{sub 0}{sup 0'5}. (author) [Russian] V doklade rassmotreny v obshchem vide otdel'nye naibolee vazhnye tekhnologicheskie kharakteristiki apparatov (na primere sfericheskogo apparata) dlya provedeniya radiatsionno-khimicheskikh protsessov v promyshlennom masshtabe. Predlozhen metod otsenki ehffektivnosti apparata lyuboj konstruktsii putem sravneniya s proizvoditel'nost' yu beskonechno bol'shogo apparata, imeyushchego tot zhe istochnik izlucheniya. Priveden raschet tekhnologicheskoj kharakteristiki apparata dlya radiatsionnoj polimerizatsii ehtilena (davlenie 200 atm, temperatura 25{sup o} C{sup 3} so sterzhnevym istochnikom gamma-izlucheni ya Co{sup 60} razlichnoj aktivnosti. Takoj apparat mozhno rasschityvat' po srednim znacheniyam moshchnostej doz, opredelyaemym po velichine ehnergeticheskogo KPD apparata. Pokazano, chto proizvoditel'nost'apparata (Q), pri prochikh ravnykh usloviyakh, yavlyaetsya stepennoj funktsiej moshchnosti (W{sub 0}) gamma-izlucheniya apparata. Dlya rassmotrennogo apparata : Q

  15. The 10 recommendations for prevention of radiation accidents in industrial gamma radiography; As 10 recomendacoes mais importantes para prevencao de acidentes radiologicos em gamagrafia industrial

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Luana Silva de

    2015-07-01

    The Industrial Gamma Radiography, as part of Industrial Radiography, stands out as the most widespread and plays an important role in the quality control of different materials and devices. However, IAEA classifies industrial gamma radiography in the Category 2 as very dangerous due to the radiological risk caused by the use of high activity radioactive sources. In March, 2012, a Brazilian Workshop on Prevention of Industrial Gamma Radiography Accident was performed by DIAPI/CNEN with the objective of disseminating knowledge about radiological accidents with radioactive sources in this application. During this Workshop, IRD/CNEN conducted a survey with 75 participants using a form with 22 recommendations to prevent radiological accidents, aiming to select the most voted. This present work aims to perform a detailed statistical study to define the Top 10 Recommendations for industrial gamma radiography operator avoids radiological accidents and to prepare a brochure with these top 10 recommendations to be distributed to all industrial gamma radiography radiation workers. Data analysis was performed using the statistical method 'Frequency Distribution', among the 75 participants categorized as General, RPO, and Other Workers of the area. The results were obtained for each category, accounting for the total of 22 recommendations in its percentage and number of votes, and the top 10 recommendations were defined to prevent radiological accidents. The first place and most important recommendation is 'Always use a personal alarm monitor throughout the work'. One of the conclusions is that the brochure with the Top 10 Recommendations shows to be understandable and useful for dissemination and training of radiation workers to avoid radiological accidents in industrial gamma radiography. (author)

  16. Methodology for determination of activity of radionuclides by gamma spectrometry; Metodologia para determinacao da atividade de radionuclideos por sistema de espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Fragoso, Maria da Conceicao de Farias; Oliveira, Victor Rogerio S. de; Oliveira, Mercia L.; Lima, Fernando Roberto de Andrade, E-mail: mariacc05@gmail.com [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-NE), Recife, PE (Brazil)

    2014-07-01

    Due to the growth in the number of procedures that make use of the positron emission tomography (PET), there is a need for standard solutions for the calibration of the systems used for the measurement of the PET radiopharmaceutical (activimeter) in radiopharmacies and in nuclear medicine services. Among the existing alternatives for the standardization of radioactive sources, the method known as gamma spectrometry is widely used for short-lived radionuclides. The purpose of this study was to implement the methodology for standardization of the {sup 18}F solutions by gamma spectrometry at the Regional Center for Nuclear Sciences of the Northeast (CRCN-NE/CNEN-NE), Brazil. (author)

  17. Determination of Th and U by neutron activation for gamma spectrometry calibration in situ; Determinacion de Th y U por activacion neutronica para calibracion de espectrometria gamma in situ

    Energy Technology Data Exchange (ETDEWEB)

    Nava M, F.; Rios M, C.; Mireles G, F.; Saucedo A, S.; Davila R, I.; Pinedo, J. L. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas (Mexico); Landsberger, S., E-mail: iqnava@hotmail.com [University of Texas at Austin, Nuclear Engineering Teaching Laboratory, Pickle Research Campus, R9000 Austin, Texas 78712 (United States)

    2012-10-15

    Using the analysis by neutron activation to determine the profile of the thorium and uranium concentration calibration factors were obtained for their use in the gamma spectrometry in situ. Three sites were selected (San Ramon, Villa de Cos y la Zacatecana) and the analysis by activation was development in the Laboratory of Nuclear Engineering Teaching of the Texas University in Austin with the nuclear reactor Ut-TRIGA. Starting from the gamma spectra in situ, the areas of normalized photo-pick of the radioisotopes were: {sup 208}Tl and {sup 228}Ac for the thorium series and {sup 214}Pb and {sup 214}Bi for the uranium series. The averages of the factors found in units of (cpm/Bq/Kg) are of 105.63{+-}8.32 and 75.87{+-}4.61 for the thorium and uranium, respectively. (Author)

  18. Dosimetric calculations by Monte Carlo for treatments of radiosurgery with the Leksell Gamma Knife, homogeneous and non homogeneous cases; Calculos dosimetricos por Monte Carlo para tratamientos de radiocirugia con el Leksell Gamma Knife, casos homogeneo y no homogeneo

    Energy Technology Data Exchange (ETDEWEB)

    Rojas C, E.L. [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Lallena R, A.M. [Universidad de Granada (Spain)

    2004-07-01

    In this work dose profiles are calculated that are obtained modeling treatments of radiosurgery with the Leksell Gamma Knife. This was made with the simulation code Monte Carlo Penelope for an homogeneous mannequin and one not homogeneous. Its were carried out calculations with the irradiation focus coinciding with the center of the mannequin as in near areas to the bone interface. Each one of the calculations one carries out for the 4 skull treatment that it includes the Gamma Knife and using a model simplified of their 201 sources of {sup 60} Co. It was found that the dose profiles differ of the order of 2% when the isocenter coincides with the center of the mannequin and they ascend to near 5% when the isocenter moves toward the skull. (Author)

  19. Use of calibration methodology of gamma cameras for the workers surveillance using a thyroid simulator; Uso de una metodologia de calibracion de camaras gamma para la vigilancia de trabajadores usando un simulador de tiroides

    Energy Technology Data Exchange (ETDEWEB)

    Alfaro, M.; Molina, G.; Vazquez, R.; Garcia, O., E-mail: mercedes.alfaro@inin.gob.m [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-09-15

    In Mexico there are a significant number of nuclear medicine centers in operation. For what the accidents risk related to the transport and manipulation of open sources used in nuclear medicine can exist. The National Institute of Nuclear Research (ININ) has as objective to establish a simple and feasible methodology for the workers surveillance related with the field of the nuclear medicine. This radiological surveillance can also be applied to the public in the event of a radiological accident. To achieve this it intends to use the available equipment s in the nuclear medicine centers, together with the neck-thyroid simulators elaborated by the ININ to calibrate the gamma cameras. The gamma cameras have among their component elements that conform spectrometric systems like the employees in the evaluation of the internal incorporation for direct measurements, reason why, besides their use for diagnostic for image, they can be calibrated with anthropomorphic simulators and also with punctual sources for the quantification of the radionuclides activity distributed homogeneously in the human body, or located in specific organs. Inside the project IAEA-ARCAL-RLA/9/049-LXXVIII -Procedures harmonization of internal dosimetry- where 9 countries intervened (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru, Uruguay and Spain). It was developed a protocol of cameras gamma calibration for the determination in vivo of radionuclides. The protocol is the base to establish and integrated network in Latin America to attend in response to emergencies, using nuclear medicine centers of public hospitals of the region. The objective is to achieve the appropriate radiological protection of the workers, essential for the sure and acceptable radiation use, the radioactive materials and the nuclear energy. (Author)

  20. Proposal of a calibration protocol of gamma chambers for estimation of the radionuclides incorporation in emergency situations; Propuesta de un protocolo de calibracion de camaras gamma para estimacion de la incorporacion de radionucleidos en situaciones de emergencia

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, B.M.; Lucena, E.; Dantas, A.L.A.; Araujo, F.; Melo, D. [Instituto de Radioprotecao e Dosimetria, Rio de Janeiro Brasil (Brazil); Teran, M.; Paolino, A. [Facultad de Quimica, Montevideo (Uruguay); Hermida, J.C. [Hospital de Clinicas, Facultad de Medicina, Montevideo (Uruguay); Rojo, A. [Autoridad Regulatoria Nuclear, Buenos Aires (Argentina); Puerta, J.A.; Morales, J. [Universidad Nacional de Colombia, Medellin (Colombia); Lopez B, G.M. [Centro de Proteccion e Higiene de las Radiaciones, Ciudad de la Habana (Cuba); Alfaro, M.; Ruiz, M.A. [Instituto Nacional de Investigaciones Nucleares (Mexico); Videla, R.; Pinones, O. [Comision Chilena de Energia Nuclear, Santiago (Chile); Gonzalez, S. [Instituto Peruano de Energia Nuclear, Lima (Peru); Navarro, T. [Centro de Investigaciones Energeticas, Medioambientales y Tecnologicas, Madrid (Spain); Cruz S, R. [International Atomic Energy Agency, Vienna (Australia)

    2006-07-01

    In the last years in several countries has come increasing the concern with the possibility of accidents related to the transport and manipulation of open sources used in nuclear medicine. This carried out to the search of alternative methods for the monitoring of workers and individuals of the public exposed to the radionuclides incorporation like {sup 131} I, {sup 201} Tl, {sup 153} Sm among others. One of the options to assist the demand for monitoring of the radionuclides incorporation is the use of gamma chambers that are medical diagnostic equipment available in the own centers of nuclear medicine. The gamma chambers are used to obtain images of patient to which are administered a radionuclide of well-known activity with diagnostic purposes. These equipment have among its components elements that spectrometric systems like those used in the evaluation of the internal incorporation for direct measurements, reason why besides its use for diagnosis by image they can be gauged with anthropomorphic simulators and also with punctual sources for the quantification of the radionuclides activity, distributed homogeneously in the human body or located in specific organs. This work presents the development of a calibration protocol of gamma chambers for the in vivo determination of radionuclides and it proposes the implementation of the protocol in centers of nuclear medicine of the 9 countries participants of the project OAS-ARCAL-RLA/9/049-LXXVIII - Harmonization of procedures of internal dosimetry (Argentina, Brazil, Colombia, Cuba, Chile, Mexico, Peru, Uruguay and Spain). The protocol is the base to establish an integrated net to attend in the response to emergencies using nuclear medicine centers of public hospitals of the region. The proposal is an additional alternative for the monitoring of people in emergency situations where it is possible and feasible the use of the gamma chambers. This would avoid the person's transport with incorporation suspicion for

  1. Primary 4{pi}{beta}-{gamma} coincidence system for standardization of radionuclides by means of plastic scintillators; Sistema primario por coincidencias 4{pi}{beta}-{gamma} para a padronizacao de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Baccarelli, Aida Maria

    2003-07-01

    The present work describes a 4{pi}({alpha},{beta})-{gamma} coincidence system for absolute measurement of radionuclide activity using a plastic scintillator in 4{pi} geometry for charged particles detection and a Nal (Tl) crystal for gamma-ray detection. Several shapes and dimensions of the plastic scintillator have been tried in order to obtain the best system configuration. Radionuclides which decay by alpha emission, {beta}{sup -}, {beta}{sup +} and electron capture have been standardized. The results showed excellent agreement with other conventional primary system which makes use of a 4{pi} proportional counter for X-ray and charged particle detection. The system developed in the present work have some advantages when compared with the conventional systems, namely; it does not need metal coating on the films used as radioactive source holders. When compared to liquid scintillators, is showed the advantage of not needing to be kept in dark for more than 24 h to allow phosphorescence decay of ambient light. Therefore it can be set to count immediately after the sources are placed inside of it. (author)

  2. Study of a 4{pi}{beta}-{gamma} coincidence system for absolute radionuclide activity measurement using plastic scintillators; Estudo de um sistema de coincidencias 4{pi}{beta}-{gamma} para a medida absoluta de atividade de radionuclideos empregando cintiladores plasticos

    Energy Technology Data Exchange (ETDEWEB)

    Piuvezam Filho, Helio

    2007-07-01

    The present work was intended to study a coincidence system 4{pi}(PS){beta}-{gamma} for absolute activity measurement using plastic scintillators in 4{pi} geometry. Along with experiments on the coincidence system, simulations were also performed applying the Monte Carlo Method, by means of codes PENELOPE and ESQUEMA. These simulations were performed in order to calculate the extrapolation curve of the coincidence system 4{pi}(PS){beta}-{gamma} and compare it to experimental data. A new geometry was proposed to the coincidence system adding up a second photomultiplier tube to the previous system for improving light collection from the plastic scintillator, as this system presented limitations in the minimum detected energy due to the presence of electronic noise and low gain. The results show that an improvement in the signal-to-noise ratio was obtained, as well as in the minimum detected energy. Moreover, there was an increase in the detection efficiency. With these modifications, it is now possible to calibrate radionuclides which emit low energy electrons or X-rays, increasing the number of radionuclides that can be standardized with this type of system.(author)

  3. Gamma Knife

    Science.gov (United States)

    ... News Physician Resources Professions Site Index A-Z Gamma Knife Gamma Knife® is a radiation therapy that uses computerized ... If you're scheduled for radiation therapy using Gamma Knife®, a treatment team consisting of a radiation ...

  4. Aplicaciones de la radiación gamma en frutas y hortalizas: Perspectivas agroindustriales para el espárrago peruano

    OpenAIRE

    Vargas, Johnny; Vivanco, Mónica; Maldonado, Marisela; Linares, Marco; Huamanlazo, Paula; Quispe, Flor de María

    2005-01-01

    Para la conservación y solución de problemas fitosanitarios en alimentos se utilizan aditivos y fumigantes químicos como métodos convencionales en su tratamiento. Sin embargo, estos son muy cuestionados por ser altamente tóxicos y perjudiciales para la salud y el medioambiente. Presentamos algunos resultados de investigaciones realizadas por el IPEN en la conservación de frutas y hortalizas, eliminación de hongos causantes de la pudrición en fresas, retardo en la maduración y/o senescencia en...

  5. Estimation of dose ionizing radiation exposure by biological dosimetry; Estimación de dosis de exposición a radiaciones ionizantes mediante dosimetría biológica

    Energy Technology Data Exchange (ETDEWEB)

    Herranz Crespo, R.; Moreno Domene, M.; Prieto Rodríguez, M.J.; Lozano Barriuso, M.A.

    2014-07-01

    the Biological Dosimetry Laboratory of the Radiopathology Centre, at Hospital General Universitario Gregorio Marañón, is the only national laboratory accredited by UNE-EN ISO/IEC 17025:2005, and scope to ISO 19238:2004 (Radiation protection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), for dose assessment by the dycentrics assay, has great experience with more than 100 real cases analyzed, and several population studies. This paper describes experience and results from more than 20 years of work under the Reference level II Centre for the attention of irradiated and/or contaminated people. [Spanish] El Laboratorio de Dosimetría Biológica, del Centro de Radiopatología del Hospital General Universitario Gregorio Marañón, es el único en España que dispone de acreditación internacional por la norma UNE-EN ISO/IEC 17025:2005 con alcance a la norma ISO 19238:2004 (Radiationprotection – Performance criteria for service laboratories performing biological dosimetry by citogenetics), para la realización de estimaciones dosimétricas mediante la técnica de dicéntricos, dispone de amplia experiencia en su aplicación en los 110 casos reales analizados, y en diferentes estudios de poblaciones españolas. En este trabajo se describe la experiencia del laboratorio y los resultados obtenidos en los más de 20 años de funcionamiento en el Centro de Referencia de nivel II para la atención a irradiados y/o contaminados por radiaciones ionizantes.

  6. Development of a methodology for radionuclide impurity analysis in radiopharmaceuticals using gamma spectrometry; Desenvolvimento de uma metodologia para analise de impurezas radionuclidicas em radiofarmacos por espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Paula, Eduardo Bonfim de; Araujo, Miriam Taina Ferreira de; Delgado, Jose Ubiratan; Poledna, Roberto; Lins, Ronaldo; Leiras, Anderson; Silva, Carlos Jose da; Oliveira, Antonio Eduardo de, E-mail: bonfim@bolsista.ird.gov.br, E-mail: miriamtaina@hotmail.com [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2016-07-01

    The LNMRI has sought to develop a methodology for the identification and accurate detection of gamma radiation impurities stations in metrological level, aiming to meet the recommendations not only of international pharmacopoeia, as well as the CNEN and ANVISA regarding the quality control can ensure patients the doses received by the practices are as low as feasible. As an initial target, it was possible to obtain an efficiency curve with uncertainty around 1% necessary to initiate future measurements of interest applied to nuclear medicine and to start the development of impurities analysis technique. (author)

  7. Hydra phantom applicability for carrying out tests of field uniformity in gamma cameras; Aplicabilidade do fantoma hydra para realizacao dos testes de uniformidade de campo em gama camaras

    Energy Technology Data Exchange (ETDEWEB)

    Aragao Filho, Geraldo L., E-mail: geraldo_lemos10@hotmail.com [Centro de Medicina Nuclear de Pernambuco (CEMUPE), Recife, PE (Brazil); Oliveira, Alex C.H., E-mail: oliveira_ach@yahoo.com [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Lopes Filho, Ferdinand J.; Vieira, Jose W., E-mail: ferdinand.lopes@oi.com.br, E-mail: jose-wilson59@live.com [Instituto Federal de Pernambuco (IFPE), Recife, PE (Brazil)

    2014-07-01

    Nuclear Medicine is a medical modality that makes use of radioactive material 'in vivo' in humans, making them a temporary radioactive source. The radiation emitted by the patient's body is detected by a specific equipment, called a gamma camera, creates an image showing the spatial and temporal biodistribution of radioactive material administered to the patient. Therefore, it's of fundamental importance a number of specific measures to make sure that procedure be satisfactory, called quality control. To Nuclear Medicine, quality control of gamma camera has the purpose of ensuring accurate scintillographic imaging, truthful and reliable for the diagnosis, guaranteeing visibility and clarity of details of structures, and also to determine the frequency and the need for preventive maintenance of equipment. To ensure the quality control of the gamma camera it's necessary to use some simulators, called phantom, used in Nuclear Medicine to evaluate system performance, system calibration and simulation of injuries. The goal of this study was to validate a new simulator for nuclear medicine, the Hydra phantom. The phantom was initially built for construction of calibration curves used in radiotherapy planning and quality control in CT. It has similar characteristics to specific phantoms in nuclear medicine, containing inserts and water area. Those inserts are regionally sourced materials, many of them are already used in the literature and based on information about density and interaction of radiation with matter. To verify its efficiency in quality control in Nuclear Medicine, was performed a test for uniformity field, one of the main tests performed daily, so we can verify the ability of the gamma camera to reproduce a uniform distribution of the administered activity in the phantom, been analysed qualitatively, through the image, and quantitatively, through values established for Central Field Of View (CFOV) and Useful Field Of View (UFOV

  8. Development of the set of corrections for a gamma camera dedicated to research; Desarrollo del conjunto de correcciones para una gammacamara dedicada a investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Gimenez Insua, M.; Ambroa Rey, E. M.; Vazquez Vazquez, R.; Sanchez Garcia, M.; Luna Vega, V.; Mosquera Sueiro, J.; Otero Martinez, C.; Lobato Busto, R.; Pombar Camean, M.

    2013-07-01

    As part of a project for animal research, replaced electronics one of the gamma-cameras (GC) of the service that was out of use, with the aim of using it for SPECT. The implementation is therefore required of the corrections that allow image quality enough for SPECT from raw data supplied by the team. This has been developed software that enables to perform correction of power, uniform and linearity on the acquired data. For validation, change in several parameters indicative of the image quality has been evaluated. (Author)

  9. The influence of gamma radiation on the aflatoxigenic fungi, phenolics content and antioxidant activity of the green tea; Irradiacao do cha verde para controle de fungos Aspergillus sp.

    Energy Technology Data Exchange (ETDEWEB)

    Lemos, S.G.; Silva, E.B.; Costa, L.F., E-mail: sloana.lemos@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear. Centro de Tecnologia e Geociencias; Nascimento, M.S. [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Centro de Ciencias Biologicas. Departamento de Antibioticos; Oliveira, I.S. [Universidade Federal de Pernambuco (CAV/UFPE), Vitoria de Santo Antao, PE (Brazil). Centro Academico de Vitoria

    2013-08-15

    The use of raw plants, including the green tea (Camelia sinensis), has been increasing in Brazil. Along with this increasing tea consumption, there are risks due to its unsuitable handling and storage, which points to the need of controlling possible contaminations. This could be achieved with the use of ionizing radiation. In this context, the present study aimed to evaluate the effect of gamma irradiation over the total phenolics amount, antioxidants and fungic activities of the green tea aqueous extract aiming its processing. Aliquots of the bulk samples have been analyzed before and after gamma irradiation (dosages of 0; 5; 7,5 and 10 kGy). The total phenolics content of the aqueous extracts was determined by using the Folin-Ciocalteu reagent having the catechin as the standard. Those same extracts were used to evaluate its ability of scavenging the free radical DPPH. The microbiological analysis were performed through irradiated samples and control. The results have allowed to check that different dosages of radiation (5; 7,5 e 10 kGy) did not induce significant differences on the content of total phenols and on the antioxidant capacity of the analyzed samples when compared to control. Also, it was also observed that the radiation may have had a catalytic effect on the oxidation of the DPPH and was effective on the microbiological control, even though it was not possible to kill the aflatoxigenic fungus. (author)

  10. Improvement in the fir production by means of the gamma radiation application; Mejora en la produccion de abeto mediante la aplicacion de radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, J., E-mail: josefina.gonzalez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    With the purpose of improving the production process of forest trees with acceptable quality as much for the market as for the reforestation, a certain technology was proven previously by ININ-ProBosque that combines the radiation application an the tissue culture, on seeds of P. macrolepis collected in Hidalgo and Mexico State. After being carried out the quality trials, the seeds coming from the Hidalgo State were divided in 7 lots (of 100 seeds each one), irradiating them, in a Gammacel 220 irradiator to dose of: 0, 5, 15, 25, 35, 45 and 55 Gy respectively. Later on, they were micro-propagated in the laboratory by the predetermined method, in order to cultivate them in a growth room with light and controlled temperatures. The results in the quality trials allowed selecting a seeds lot collected in the Hidalgo State with percentages of viability, germination and full seed bigger to those reported for seeds coming from the Mexico State. With respect to the irradiation, the survival results obtained after 40 days post-irradiation, for the Pseudotsuga seed ecotype Capuli was determined a half dose lethal understood among the 45 and 50 Gy. On the other hand, was observed that the plantules coming from dose minors to the LD{sub 50} (5 and 35 Gy) were individualized and they grew in a smaller time that the witness, developing an incipient radicule system, absent when the seeds have not been irradiated. Is necessary to mention that the dose of 35 Gy not only allowed the development of a radicule system but also a better aspect of the plantules that involves a major needles number without deformation and whose color suggests a bigger vigor. At the moment they are established in parcel an average of 800 Pseudotsuga plants (previously irradiated to 5 and 35 Gy) and whose development will be analyzed during the following 2 years. (author)

  11. Polymerization of soybean oil by gamma radiation via, morphological and structural characterization; Polimerizacion de aceite de soya via radiacion gamma, caracterizacion morfologica y estructural

    Energy Technology Data Exchange (ETDEWEB)

    Martin del Campo L, E. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2006-07-01

    This work is divided in five chapters with very defined topics that allow to approach in a better way to the central topic of the investigation. In the chapter I, general information on the polymers and some fundamental concepts of radiation are presented. The chapter II, is focused to the information that makes reference to the oils used in this work. In the chapter III, the basic theory on the characterization techniques used in the analysis of the materials is mentioned. The chapter IV, it describes to detail the whole experimental part used for the polymerization. In the chapter V, all the generated results during the investigation are discussed; and lastly, the final conclusions of the work are given. (Author)

  12. Conjunct action of gamma radiation and casiopeinas in two cellular types; Accion conjunta de radiacion gamma y casiopeinas en dos tipos celulares

    Energy Technology Data Exchange (ETDEWEB)

    Ramos V, N.I

    2006-07-01

    In Mexico the cancer occupies the second place in the causes of death and although already there are diverse useful treatments to attack this suffering, the search of new pharmaceuticals that present positive effect in the treatment of the cancer there is taken to the development of a group of substances called Casiopeinas. Its are coordination compounds constituted by a central atom of copper (Cu II) joined to organic ligands, with general condensed formula [Cu (NN)(ON)]NO{sub 3}, or [Cu(NN)(OO)]NO{sub 3}. Its present different cytotoxicity levels, as well as in vitro antineoplastic activity in diverse tissues derived of tumors. Even its ignore the mechanisms of it action, but one of them, it could be by generation of reactive species of oxygen (ERO), mediated by the metallic center that contain. Thinking of this possibility was carried out in vitro experiments, exposing lymphocytes or HeLa cells, to ionizing radiation, at two casiopeinas (Casiopeina llgly and the Casiopeina Ill-e-a) or the combination of both agents, in order to determine if the antineoplastic capacity of both types of treatments increase in conjunct action. To determine it its were carried out cytotoxicity tests by means of the differential dyeing of fluorescein diacetate and etidio bromide, in these the cells alive fluorescein in green color while the dead ones only the nucleus of red tinged. The genotoxicity was evaluated by means of the comet essay. The results hurtled that as much the casiopeinas as the radiation by separate don't present difference among both cellular types, probably due to the used method that only quantifies the damages at the moment and not to long term. And according to those treatments on the whole only to the concentrations and the doses more high it favors the additive effect due to an overproduction of free radicals that not can be neutralized. According to the genotoxicity, only proven for the radiation indicates that the HeLa cells presents a major number of cells with damages in comparison of the lymphocytes. (Author)

  13. Detection system and processing of signals originated by backscattering gamma radiation; Sistema de deteccion y procesamiento de senales originadas por radiacion gamma retrodipersada

    Energy Technology Data Exchange (ETDEWEB)

    Baltuano E, O R

    1996-12-31

    In order to answer to the requirements of some groups of work destined to carry out studies about soil density and position of steel bars in reinforced cement, using NaI solid scintillation detectors, the electronics required by this type of detectors has been designed and implemented. In this first phase, the construction and test of the 5 modules that constitute the spectrometry chain-which has a digital control: high-tension source, amplifier, control interphase, analog to digital converter (ADC) and multichannel analyzers (MCA) storage logic-were finished. For the development of the operation tests, a compatible computer was used, while the construction of the control logic was finished. This control logic, linked to the implemented analog phases, will provide a totally portable system. The system was evaluated, generating the spectra of some well-known radioactive samples using a 2 inch x 2 inch scintillation detector, having as a result a total resolution of 8,6% (related to the photopeak of Cs-137) The ADC Wilkinson type has a maximum resolution of 2048 channels. Because of the fulfillment of the above-mentioned studies with backscattered beams, all the related electronics was designed considering this criterion. That is why neither base line restoration circuits nor piling-up rebound circuits were included in the amplifier, because the radiation beam to be studied had low activity. By the same reason and in order to avoid the unnecessary complexity and the high cost of the electronics circuits, the ADC operates at a relatively low frequency of 16 MHz. Afterwards, it is expected to interconnect all the system to a laptop compatible computer. In this way, we would have a higher versatility for the modification of the operation parameters of the spectrometry chain during the field tests that may be carried out. (author). 26 refs., 29 tabs., 121 figs.

  14. Conjunct action of gamma radiation and casiopeinas in two cellular types; Accion conjunta de radiacion gamma y casiopeinas en dos tipos celulares

    Energy Technology Data Exchange (ETDEWEB)

    Ramos V, N I

    2006-07-01

    In Mexico the cancer occupies the second place in the causes of death and although already there are diverse useful treatments to attack this suffering, the search of new pharmaceuticals that present positive effect in the treatment of the cancer there is taken to the development of a group of substances called Casiopeinas. Its are coordination compounds constituted by a central atom of copper (Cu II) joined to organic ligands, with general condensed formula [Cu (NN)(ON)]NO{sub 3}, or [Cu(NN)(OO)]NO{sub 3}. Its present different cytotoxicity levels, as well as in vitro antineoplastic activity in diverse tissues derived of tumors. Even its ignore the mechanisms of it action, but one of them, it could be by generation of reactive species of oxygen (ERO), mediated by the metallic center that contain. Thinking of this possibility was carried out in vitro experiments, exposing lymphocytes or HeLa cells, to ionizing radiation, at two casiopeinas (Casiopeina llgly and the Casiopeina Ill-e-a) or the combination of both agents, in order to determine if the antineoplastic capacity of both types of treatments increase in conjunct action. To determine it its were carried out cytotoxicity tests by means of the differential dyeing of fluorescein diacetate and etidio bromide, in these the cells alive fluorescein in green color while the dead ones only the nucleus of red tinged. The genotoxicity was evaluated by means of the comet essay. The results hurtled that as much the casiopeinas as the radiation by separate don't present difference among both cellular types, probably due to the used method that only quantifies the damages at the moment and not to long term. And according to those treatments on the whole only to the concentrations and the doses more high it favors the additive effect due to an overproduction of free radicals that not can be neutralized. According to the genotoxicity, only proven for the radiation indicates that the HeLa cells presents a major number of cells with damages in comparison of the lymphocytes. (Author)

  15. Calibration of a Gamma Spectrometry System Used for the Determination of Cs-137 in Spanish Soils; Puesta a Punto de un sistema de Expectrometria Gamma para la Determinacion de Cs-137 en Suelos Espanoles

    Energy Technology Data Exchange (ETDEWEB)

    Barreraa, M.; Romero, M. L.; Valino, F.

    2008-07-01

    The document describes the methodology used at CIEMAT in order to determine, by gamma spectrometry, the background levels of the radionuclide Cs-137 in soils of the Spanish peninsular territory. the work is a part of an extensive research project developed jointly by the University of the Basque Country (UPV-EHU) and the CIEMAT, endellite Content and migration of radiocaesium and radiostrontium in Spanish soils, which is funded by the Plan I+D of the Spanish Nuclear Security Council (CSN). The objective of the project is to establish the reference levels of man-made radionuclides in Spanish soils, with respect to which the evaluation of a possible posterior accidental release of radioactive material could be appraised. The activity concentration of the fission products Cs-137 has been determined in 34 soil cores extracted from representative Spanish soils type zones. This publication describes the experimental system employed, its calibration, the particular conditions applied to perform the measurements, as well as the experimental validation of the methodology. The activity profiles and inventories of the radioactive element so obtained are also presented. The estimation of the background Cs-137 reference levels, will provide a basis for later applications as the study of the spatial distribution in the region, the determination of the correlation between the deposited activity and the meteorological conditions, or the calculation of the specific migration parameters of the radioactive elements in Mediterranean conditions. (Author) 15 refs.

  16. Radar, geologic, airborne gamma ray and Landsat TM digital data integration for geological mapping of the Estrela granite complex (Para State)

    International Nuclear Information System (INIS)

    Cunha, Edson Ricardo Soares Pereira da

    2002-01-01

    This work is focused on the geotectonic context of the Carajas Mineral Province, Amazon Craton, which represents the most important Brazilian Mineral Province and hosts iron, cooper, gold, manganese and nickel deposits. At the end of Archean age, during the techno-metamorphic evolution, moderated alkaline granitoids were generated, such as, Estrela Granite Complex (EGC). This work has used digital integration products with the purpose of study the granite suite, its host rock, and the surrounded area. The digital integrated data were gamma-ray and geological data with satellite images (SAR-SAREX e TM-Landsat). The geophysics data, originally in 32 bits and grid format, were interpolated and converted to 8 bits images. The geological data (facies map) was digitalized and converted to a raster format. The remote sensing images were geometrically corrected to guarantee an accuracy on the geological mapping. On the data processing phase, SAR images were digital integrated with gamma-ray data, TM-Landsat image and the raster facies map. The IHS transformation was used as the technique to integrate the multi-source data. On the photogeological interpretation, SAR data were extremely important to permit the extraction of the main tectonic lineaments which occur on the following directions: +/- N45W, +/- N70W, +/- NS, +/- N20E, +/- N45E e +/- N75E. This procedure was done both in analogic and automatic form, being the automatic process more useful to complement information in the extracting process. Among the digital products generated, SAR/GAMA products (uranium, thorium and total count) were the ones that give the most important contribution. The interpretation of the SAR/GAMA's products added to the field campaign have allowed to map the limits of units that occur in the region and four facies of the Estrela Granite Complex were detected. The origin of the granite suite might be related to a magmatic differentiation or to distinct intrusion pulses. The use of the

  17. Effect of gamma radiation in peanuts for inhibition of Aspergillus flavus and nutritional composition; Irradiacao gama em amendoim para controle de Aspergillus flavus

    Energy Technology Data Exchange (ETDEWEB)

    Costa, L.F.; Silva, E.B. da, E-mail: lauryfrancis@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Departamento de Energia Nuclear; Oliveira, I.S. [Universidade Federal de Pernambuco (CAV/UFPE), Vitoria de Santo Antao, PE (Brazil). Centro Academico de Vitoria

    2013-08-15

    Care in food storage, controlling humidity and temperature, prevents fungal diseases in peanuts and the development of filamentous fungi in food and feed, which can result in the production of toxins known as mycotoxins. Ionizing radiation is a preventive method of food security, promoting inhibition of buds, delayed maturation, reduction of microbial load, elimination of pathogenic microorganisms, sterilization and disinfection in grains, cereals, fruits and spices. This work aimed to evaluate the effects of gamma radiation on the growth inhibition of aflatoxigenic fungi and on nutritional composition in peanut. Samples were collected directly from the producer (Petrolandia) and Supply Central of Pernambuco (CEASA-PE), and then grains inside / outside pods were packed and subjected to irradiation at doses of 6, 9, 12 and 15 kGy. Fungal growth and nutritional composition of the samples before and after irradiation were analyzed and statistical analysis using the Mann-Whitney-Wilcoxon. The results showed that the samples originated from CEASA-PE had the highest rates of contamination. The radiation was effective in the inhibition of aflatoxigenic fungi, achieving to eliminate the action of fungi, regardless of dose. Only one non-irradiated sample, originated from CEASA-PE, showed positive production of aflatoxins in the middle LCA. No significant difference in the values of the nutritional composition, with increasing radiation dose. The irradiation was shown to be an effective process for preserving peanuts, because it prevents the growth of fungi, particularly aflatoxin producer, making it safer for consumption, without changing its nutritional composition. (author)

  18. The Use of Ionizing Radiation in the Vulcanization of Silicon Rubber; Utilisation des radiations ionisantes pour la vulcanisation du caoutchouc au silicone; Ispol'zovanie ioniziruyushchikh izluchenij dlya vulkanizatsii silikonovogo kauchuka; Empleo de las radiaciones ionizantes en la vulcanizacion del caucho de siliconas

    Energy Technology Data Exchange (ETDEWEB)

    Kuzminsky, A S; Nikitina, T S; Oksentevich, L A [Rubber Research Institute, Moscow, Union of Soviet Socialist Republics (Russian Federation)

    1960-07-15

    temperaturas (150{sup o}, 200{sup o} y 250{sup o}). La irradiacion permite disminuir la temperatura de vulcanizacion y prescindir de un almacenamiento prolongado a temperatura regulada, que de otro modo es necesario despues de la vulcanizacion. El negro de humo puede utilizarse como material de carga para el caucho vulcanizado con arreglo al nuevo metodo. Los autores llegan a la conclusion de que el empleo de las radiaciones ionizantes se traduce en una simplificacion de la tecnologia de la vulcanizacion del caucho de siliconas y en un mejoramiento de las propiedades de los productos obtenidos. (author) [Russian] Osnovnaya tsel' raboty - podrobnoe izuchenie svojstv materialov, poluchaemykh v rezul'tate oblucheniya smesej polidimetil-siloksanovogo kauchuka s razlichnymi napolnitelyami (spetsial'naya kremnekislota, dvuokis' titana, kanal'naya, pechnaya i lampovaya sazha). Obluchenie provodilos' na moshchnoj rentgenovskoj ustanovke i na istochnike {gamma}-izlucheniya So{sup 60} aktivnost'yu 20 000 g-ehkv. radiya. Otsenena otnositel'naya skorost' obrazovaniya prostranstvennoj setki vulkanizatov (po velichine ravnovesnogo modulya i maksimal'noj stepeni nabukhaniya v benzole). Rassmotreno izmenenie soprotivleniya razryvu i otnositel'nogo udlineniya v protsesse oblucheniya. Vybrany optimal'nye rezhimy vulkanizatsii i opredeleny osnovnye fiziko-mekhanicheskie pokazateli vulkanizatov. Issledovano izmenenie svojstv radiatsionnykh vulkanizatov v protsesse teplovogo stareniya pri razlichnykh temperaturakh (150, 200 i 250{sup o}). Radiatsionnaya vulkanizatsiya isklyuchaet neobkhodimost ' provedeniya protsessa pri vysokikh temperaturakh i dlitel'noe termostatirovanie posle vulkanizatsii . Novyj sposob vulkanizatsii pozvolyaet primenyat' v kachestve napolnitelej uglerodnye sazhi. Ispol'zovanie ioniziruyushchikh izluchenij pozvolyaet uprostit' tekhnologiyu vulkanizatsii silikonovogo kauchuka i uluchshit' svojstva vulkanizatov. (author)

  19. Production of vegetation samples containing radionuclides gamma emitters to attend the interlaboratory programs; Producao de amostras de vegetacao contendo radionuclideos emissores gama para participar de programas interlaboratoriais

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Poliana Santos de

    2016-07-01

    The production of environmental samples such as soil, sediment, water and vegetation with radionuclides for intercomparison tests is a very important contribution to environmental monitoring. Laboratories that carry out such monitoring need to demonstrate that their results are reliable. The IRD National Intercomparison Program (PNI) produces and distributes environmental samples containing radionuclides used to check the laboratories performance. This work demonstrates the feasibility of producing vegetation (grass) samples containing {sup 60}Co, {sup 65}Zn, {sup 134}Cs, and {sup 137}Cs by the spike sample method for the PNI. The preparation and the statistical tests followed the ISO guides 34 and 35 recommendations. The grass samples were dried, ground and passed through a sieve of 250 μm. 500 g of vegetation was treated in each procedure. Samples were treated by two different procedures:1) homogenizing of the radioactive solution containing vegetation by hand and drying in an oven and 2) homogenizing of the radioactive solution containing the vegetation in a rotatory evaporator and drying in an oven. The theoretical activity concentration of the radionuclides in the grass had a range of 593 Bq/kg to 683 Bq/kg. After gamma spectrometry analysis the results of both procedures were compared as accuracy, precision, homogeneity and stability. The accuracy, precision and short time stability from both methods were similar but the homogeneity test of the evaporation method was not approved for the radionuclides {sup 60}Co and {sup 134}Cs. Based on comparisons between procedures was chosen the manual agitation procedure for the grass sample for the PNI. The accuracy of the procedure, represented by the uncertainty and based on theoretical value had a range between -1.1 and 5.1% and the precision between 0.6 a 6.5 %. This result show is the procedure chosen for the production of grass samples for PNI. (author)

  20. Descontaminación del ingrediente farmacéutico activo de Rhizophora mangle L. mediante radiaciones ionizantes

    Directory of Open Access Journals (Sweden)

    Yanet Rodríguez Perdomo

    2011-12-01

    Full Text Available El objetivo del presente trabajo fue determinar la dosis de radiación gamma eficaz para descontaminar el extracto seco de corteza de Rhizophora mangle L. (mangle rojo. Se obtuvieron 3 lotes de este ingrediente farmacéutico activo secado en un Spray dryer y se irradiaron en una instalación Gammacell-500 con una tasa de dosis de 6,26 kGy/h, evaluando 3 dosis (3, 5 y 8 kGy. El control del proceso de irradiación se realizó empleando dosímetros de sulfato cérico. Se determinó el límite microbiano y el contenido de taninos de cada lote del ingrediente farmacéutico activo irradiado a las diferentes dosis probadas. A partir de los resultados obtenidos se alcanzó una reducción de 2 ciclos de desarrollo logarítmico de los lotes irradiados a las dosis de 5 y 8 kGy, con respecto a la carga contaminante inicial y la concentración de taninos de los lotes irradiados a diferentes dosis se mantuvo dentro de los límites de especificación, sin diferir respecto al producto no tratado. Se estableció 5 kGy como dosis de descontaminación del ingrediente farmacéutico activo seco de mangle rojo, de esta manera se logra garantizar un producto conforme para la obtención de nuevos preparados farmacéuticos.

  1. Gamma astronomy

    International Nuclear Information System (INIS)

    Cesarsky, C.; Cesarsky, J.P.

    1986-01-01

    This article overviews the gamma astronomy research. Sources already observed, and what causes to give to them; the galactic radiation and its interpretation; techniques already used and current projects [fr

  2. Gamma Spectroscopy

    NARCIS (Netherlands)

    Niemantsverdriet, J.W.; Butz, Tilman; Ertl, G.; Knözinger, H.; Schüth, F.

    2008-01-01

    No abstract. The sections in this article are 1 Introduction 2 Mössbauer Spectroscopy 3 Time-Differential Perturbed Angular Correlations (TDPAC) 4 Conclusions and Outlook Keywords: Mössbauer spectroscopy; gamma spectroscopy; perturbed angular correlation; TDPAC

  3. Efectos de las radiaciones electromagnéticas de la telefonía móvil sobre los insectos

    OpenAIRE

    Balmori Martínez, Alfonso

    2006-01-01

    Se presenta una revisión de estudios de laboratorio realizados exponiendo insectos a radiaciones electromagnéticas en el rango de las microondas, similares a las utilizadas por los sistemas de telefonía que se utilizan actualmente, y a campos electromagnéticos de baja frecuencia. Las microondas pulsadas y moduladas de la telefonía son un reciente contaminante ubicuo, cuyas consecuencias todavía no han podido ser evaluadas convenientemente. Los estudios realizados indican efectos sobre este...

  4. Windows with selective covering to the solar radiation based in copper for saving energy; Ventanas con recubrimiento selectivo a la radiacion solar basado en cobre que permiten el ahorro de energia

    Energy Technology Data Exchange (ETDEWEB)

    Correa, Genaro; Almanza, Rafael [Instituto de Ingenieria UNAM, Mexico, D.F. (Mexico)

    2000-07-01

    savings and the necessary strategies for such aim, based on the geographic region. [Spanish] Se presentan los resultados de un esfuerzo por contribuir al desarrollo de nuevos elementos constructivos acordes a las necesidades bioclimaticas de las edificaciones en Mexico que propicien el ahorro de energia. Se desarrollaron ventanas con dos tipos de recubrimientos, uno exclusivamente de oxido cuproso (Cu{sub 2}O), y otro resultado del deposito sucesivo de una pelicula de sulfuro cuprico (CuS) sobre otra de oxido cuproso. El segundo tipo de ventanas presento un adecuado control al paso de la radiacion infrarroja, lo que permite reducir aun mas la cantidad de radiacion calorifica que pasa a traves de la ventana. Durante las condiciones de calentamiento, estas ventanas dejan pasar en el peor de los casos, la mitad del calor, reduciendo la carga termica al interior de la habitacion o del edificio. Durante condiciones de enfriamiento, la ventana permite la salida del calor a la mitad de la velocidad, manteniendo durante mas tiempo la temperatura de confort del interior. Los recubrimientos de los mencionados compuestos de cobre fueron fabricados en los laboratorios de los Institutos de Ingenieria y Fisica de la Universidad Nacional Autonoma de Mexico (UNAM). Se utilizo la tecnica de erosion ionica o sputtering de un blanco de cobre 99.999% con ayuda de un plasma compuesto de argon (70%) y oxigeno (30%), que posibilita la oxidacion del cobre y el deposito del Cu{sub 2}O. Se utilizo un sustrato de vidrio flotado comercial de 600x400 mm., este tamano del vidrio estuvo determinado por las limitaciones de espacio de nuestra camara de deposito. La ventana asi obtenida presenta una agradable coloracion amarillenta y gran luminosidad, sin embargo, en el infrarrojo cercano, unicamente bloquea el 50%. Para las propiedades deseadas de control termico era necesario reducir aun mas el paso del calor. Para ello se incorporo una pelicula de sulfuro cuprico con la cual fue posible alcanzar

  5. Gamma camera

    International Nuclear Information System (INIS)

    Berninger, W.H.

    1975-01-01

    The light pulse output of a scintillator, on which incident collimated gamma rays impinge, is detected by an array of photoelectric tubes each having a convexly curved photocathode disposed in close proximity to the scintillator. Electronic circuitry connected to outputs of the phototubes develops the scintillation event position coordinate electrical signals with good linearity and with substantial independence of the spacing between the scintillator and photocathodes so that the phototubes can be positioned as close to the scintillator as is possible to obtain less distortion in the field of view and improved spatial resolution as compared to conventional planar photocathode gamma cameras

  6. Water disinfection with solar radiation; Desinfeccion del agua con radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Alejandra; Cortes, Juana E; Rodriguez, Miriam; Mundo, Alfredo; Vazquez, Sandra [Instituto Mexicano de Tecnologia del Agua, Jiutepec, Morelos (Mexico); Estrada, Claudio A [Centro de Investigacion en Energia, Temixco, Morelos (Mexico)

    2000-07-01

    Water disinfection by exposure to solar radiation is a low cost and easy application option to rural communities. The treatment of water can be done using plastic bags or plastic bottles of two litters setting on a reflective material. The efficient of the plastic bottles is lower than the one plastic bags, but the plastic bottles have a much better control of the treated water avoiding its recontamination. In order to increase the efficiency of disinfection using plastic bottles, two solar concentrators, using flat mirrors, were designed and built. Effluent water from a treatment plant of residual waters was used for the testing. Several comparison were carried out taking into account the position of the concentrators, the transparency of the bottles and the bags. The results show that using the concentrator that adjust its position to the sun every hour, a 100% disinfection is obtained in 4 hours of direct exposure to the sun rays in a sunny day. The period of time can be reduced up to 2 hours, if instead using transparent bottles, the bottles are black painted at their bottom half. With these results, the basis to design a cheap concentrator of easy construction to be used in rural communities have been settle. [Spanish] La desinfeccion del agua por exposicion a la luz solar fotodesinfeccion es una opcion de bajo costo y facil aplicacion para las comunidades rurales. El tratamiento puede llevarse a cabo utilizando bolsas o botellas de plastico transparente de dos litros de capacidad colocadas sobre un material reflejante. Las botellas son menos eficientes que las bolsas, pero permiten un mejor control del agua tratada evitando su recontaminacion. Para aumentar la eficiencia de la desinfeccion utilizando las botellas, se disenaron y construyeron dos concentradores solares de espejos planos que permitieron disminuir el tiempo de exposicion requerido cuando se utilizan estas. Para las pruebas de desinfeccion se utilizo agua del efluente de una planta de tratamiento

  7. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, Ul; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is replaceably mounted in the ray inlet opening of the camera, while the others are placed on separate supports. Supports are swingably mounted upon a column one above the other

  8. Gamma camera

    International Nuclear Information System (INIS)

    Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    The design of a collimation system for a gamma camera for use in nuclear medicine is described. When used with a 2-dimensional position sensitive radiation detector, the novel system can produce superior images than conventional cameras. The optimal thickness and positions of the collimators are derived mathematically. (U.K.)

  9. Thermoluminescent Dosimeter as the Gamma Component of a Nuclear Accident Dosimeter; Utilisation du Dosimetre Thermoluminescent Comme Element Detecteur Gamma d'un Dosimetre pour les cas d'Accident Nucleaire; 0422 0415 0420 041c 0414 ; Los Detectores de Termoluminiscencia Como Elemento Gammametrico de un Dosimetro para Casos de Accidente Nuclear

    Energy Technology Data Exchange (ETDEWEB)

    Handloser, J. S. [Edgerton, Germeshausen and Grier, Inc., Santa Barbara, CA (United States)

    1965-06-15

    ) [Spanish] En los dosimetros para caso de accidente nuclear se han empleado como gammametro diversos tipos de detectores gamma, tales como dosimetros de vidrio, dosimetros de pelicula, dosimetros quimicos y dosimetros de polimerizacion. Pero el autor llego a la conclusion de que el dosimetro de termoluminiscencia ofrece notables ventajas sobre todos esos tipos. El amplio intervalo de medicion del dosimetro de termoluminiscencia permite, en efecto, su empleo como aparato de control radiologico cotidiano y como dosimetro para caso de accidente. Esta duplicidad elimina la necesidad de disponer de instrumentos especiales para la dosimetria en caso de accidente, y permite utilizar con tal objeto los instrumentos, de uso diario, bien calibrados. Por regla general, el intervalo de medicion propio del dosimetro de termoluminiscencia abarca desde 5 mr a 100 000 r, con reproducibilidad de {+-}10%. El autor ha disenado y construido un dosimetro de fluoruro de calcio, de tipo unico, asi como el correspondiente equipo para su lectura, cuyo intervalo de medicion es de 5 mr a 5000 r. La lectura del dosimetro se efectua calentando el fosforo y midiendo la luz emitida. Se dispone de instrumentos para lecturas que abarcan seis potencias de diez y se han disenado sistemas totalmente automatizados. La lectura con ayuda de estos aparatos solo exige 20 s por dosimetro. Otra ventaja del dosimetro de termoluminiscencia es su baja respuesta neutronica. Esta respuesta variara con el tipo de envoltura y con la naturaleza del fosforo empleados. Un determinado tipo de dosimetro de fluoruro de calcio tiene una respuesta neutronica de 0,27 *10{sup -9} rad/n * cm{sup 2}. El autor describe dos modelos de dosimetros de termoluminiscencia. El primero consiste en un dosimetro de calentamiento interno encerrado en una capsula de vidrio en cuyo interior se ha hecho el vacio; sus dimensiones aproximadas son: 1 cm de diametro y 6 cm de longitud. El segundo modelo esta formado por un tubo de vidrio de pequeno

  10. Recomendaciones para la fotoprotección en la edad pediátrica, una propuesta basada en evidencias científicas

    Directory of Open Access Journals (Sweden)

    Pilar María Acuña Aguilarte

    Full Text Available Introducción: el incremento mundial del cáncer de piel y otras afecciones relacionadas con las radiaciones ultravioletas ha sido reconocido por la Organización Mundial de la Salud, que ha llamado a trazar estrategias de prevención. En el mundo existen diferentes posturas relacionadas con la fotoprotección, y la Organización Mundial de la Salud, entre sus recomendaciones, enfatiza en no exponer a las radiaciones ultravioletas de forma directa a los niños menores de 1 año, pero las recomendaciones varían entre países y organismos internacionales. Objetivo: elaborar recomendaciones basadas en evidencias científicas para la fotoprotección de niños y adolescentes cubanos. Desarrollo: se empleó un diseño cualitativo, con un acercamiento de investigación documental. Se emplearon motores de búsqueda y bases de datos disponibles en la Biblioteca Virtual de Salud, y se buscaron descriptores relacionados con el tema de fotoprotección, publicados en inglés y español entre 2002 y el 2012. Se obtuvieron evidencias científicas sobre el incremento de las radiaciones ultravioletas y su influencia en el ser humano. Se realizaron recomendaciones que fueron evaluadas por un grupo de expertos en el tema. Conclusiones: los puericultores pueden disponer de recomendaciones actualizadas para la fotoprotección de niños y adolescentes sanos cubanos, entre las cuales se incluyen, evitar la exposición directa del recién nacido a las radiaciones solares hasta los 6 meses de vida, clasificar el fototipo cutáneo de cada niño o adolescente y ofrecer indicaciones diferenciadas, así como dirigir la educación en las medidas de fotoprotección a toda la familia y la comunidad.

  11. Effect of the ionizing radiation in polymers; Efecto de la radiacion ionizante en polimeros

    Energy Technology Data Exchange (ETDEWEB)

    Martinez P, M. E.; Carrasco A, H. [ININ, Gerencia de Aplicaciones Nucleares en la Salud, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico); Benavides C, R., E-mail: esther.martinez@inin.gob.m [Centro de Investigacion en Quimica Aplicada, Blvd. Enrique Reyna Hermosillo No. 140, Col. Los Pinos, 25250 Saltillo, Coahuila (Mexico)

    2010-07-01

    Particularly, the polymers present three main effects when are exposed to radiation: inter crossing or reticulation, degradation or breaking and tolerance. Depending on the polymer structure, of the energy quantity absorbed by mass unit (dose), the concentration and the inter crossing agent dispersion and of the irradiation conditions; inert atmosphere or air and the temperature to which the irradiation is made, some of those effects is favored. The polymers that are used as isolations of cables and electric wires for specific applications require mechanical and electric properties superiors to those of the conventional materials. So, it is desirable that an insulating subjected to the high temperature produced by an electric discharge is not melted, what is associated to an inter crossed structure. Among the years 1983 and 1984, the IAEA advised to the Instituto Nacional de Investigaciones Nucleares (ININ) in diverse uses of the irradiation technology in the polymers area. Starting from then, it is began to research the effect of the gamma radiation in formulations based on polyethylene of low density/copolymer of ethylene vinyl acetate, using trimethylol-propane trimetacrilate like inter cross agent and with conventional preservatives, such as flame dilators, antioxidants, lubricants, etc., used in the cables industry and electric wires. In this chapter the result of the researches realized by the area of the ININ are given. (Author)

  12. Gamma Monitoring of Land Surfaces; Controle Gamma des Surfaces Terrestres; 0413 0410 041c 041c 0410 - 0414 ; Control de la Actividad Gamma en la Superficie del Terreno

    Energy Technology Data Exchange (ETDEWEB)

    Ophel, I. L.; Jones, A. R. [Environmental Research and Radiation Dosimetry Branch, Division of Biology and Health Physics, Atomic Energy of Canada Limited, Chalk River, ON (Canada)

    1960-07-01

    ha acoplado un dispositivo para transportar una fuente patron de radio. El aparato es insensible a los rayos cosmicos y cuando el vehiculo se desplaza a 16 km/h las lecturas efectuadas representan el 80 por ciento de las obtenidas cuando el contador permanece inmovil. La medicion de la radiactividad en las carreteras que atraviesan la zona del reactor, acompanada de lecturas complementarias en puntos fijos de control distantes 100 metros de la carretera y 3.2 km entre si, ha demostrado que la radiacion ambiente en las carreteras es muy uniforme, alcanzando un promedio de 6 {mu}r/h. Los valores hallados en los puntos de control varian de 4,5 a 7,0 {mu}r/h. (author) [Russian] Bystroe provedenie dozimetricheskogo kontrolja zemnoj poverhnosti polezno dlja opredelenija razmerov ploshhadi, popavshej pod vozdejstvie radioaktivnogo zagrjaznenija vozduha ili dlja obnaruzhenija dlitel'nogo zarazhenija okruzhajushhej sredy. Dlja podgotovitel'nogo issledovanija mesta, kotoroe okruzhaet ploshhadku jenergeticheskogo rajona NPD okolo Chok-River, ispol'zovalsja massivnyj kontrol'nyj pribor, sposobnyj proizvodit' nepreryvnuju registraciju pri ustanovke ego na avtomobile. On sostoit iz antracenovogo kristallicheskogo schetchika gamma-luchej so shemoj fotoumnozhitelja usilenija impul'sov skorosti scheta - usilitel' postojannogo toka - 1 tA serija impul'sov samopisca.' Jeto oborudovanie vesit 28 kilogrammov i ustanavlivaetsja pri pomoshhi dvuh boltov na bufer villisa. Ego mozhno snjat' i ustanovit' na trenozhnike na takuju zhe vysotu nad zemlej. Vnutri avtomobilja ustanavlivaetsja rtutnaja batareja. Shemy rabotajut na poluprovodnikah. Dlja standartnogo istochnika radiokalibrovki ustanavlivajutsja zazhimnye prisposoblenija. Pribor ne chuvstvitelen k kosmicheskomu izlucheniju i pri skorosti dvizhenija mashiny 16 km/chas otschety dostigajut 80% teh, kotorye poluchajutsja pri nepodvizhnoj ustanovke schetchika. Obsledovanie dorogi na territorii NPD pri schete, snjatom takzhe na ustanovlennyh

  13. Gamma camera

    International Nuclear Information System (INIS)

    Reiss, K.H.; Kotschak, O.; Conrad, B.

    1976-01-01

    A gamma camera with a simplified setup as compared with the state of engineering is described permitting, apart from good localization, also energy discrimination. Behind the usual vacuum image amplifier a multiwire proportional chamber filled with trifluorine bromium methane is connected in series. Localizing of the signals is achieved by a delay line, energy determination by means of a pulse height discriminator. With the aid of drawings and circuit diagrams, the setup and mode of operation are explained. (ORU) [de

  14. Gamma irradiator

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    Fiability of devices set around reactors depends on material resistance under irradiation noticeably joints, insulators, which belongs to composition of technical, safety or physical incasurement devices. The irradiated fuel elements, during their desactivation in a pool, are an interesting gamma irradiation device to simulate damages created in a nuclear environment. The existing facility at Osiris allows to generate an homogeneous rate dose in an important volume. The control of the element distances to irradiation box allows to control this dose rate [fr

  15. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1987-06-01

    The mapping of gamma sources radiation emission in a nuclear plant is an important safety point. A remote gamma ray mapping process was developed in SPS/CEA/SACLAY. It uses the ''pinhole camera'' principle, precursor of photography. It mainly consists of a radiation proof box, with a small orifice, containing sensitive emulsions at the opposite. A first conventional photographic type emulsion photographs the area. A second photographic emulsion shows up the gamma radiations. The superim position of the two shots gives immediate informations of the precise location of each source of radiation in the observed area. To make easier the presentation and to improve the accuracy of the results for radiation levels mapping, the obtained films are digitally processed. The processing assigns a colours scale to the various levels of observed radiations. Taking account physical data and standard parameters, it gets possible to estimate the dose rate. The device is portable. Its compactness and fully independent nature make it suitable for use anywhere. It can be adapted to a remote automatic handling system, robot... so as to avoid all operator exposure when the local dose rate is too high [fr

  16. Automated System of Area Radiation Measurement (ASARM); Sistema Automatizado de Medicion de Radiacion de Area (SAMRA)

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez G, J., E-mail: jaime.hernandez@inin.gob.mx [ININ, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2013-10-15

    The realized activities in nuclear facilities involve the determination of the presence of ionizing radiation fields in the workspaces. The instruments designed to detect and to measure these radiation fields provide useful information (specific type of radiation, intensity, etc.) to take the appropriate radiological protection measures, with the purpose of reducing to the minimum the workers exposition and the people in general. The radiological protection program of Reactor TRIGA Mark III contains the instructions and procedures to implement a periodic radiological monitoring, surveillance, rising of contamination levels, type and number of the instruments required for the radiological monitoring of areas and personal. The ana logical monitoring system model Rms II used to detect and measuring exposition speed and neutron radiation fields in several areas of the installation, provides the information in a logarithmic scale measurer of 4 or 5 decades located in a shelf where the previously mentioned measurement channels are centralized. Also inside the reactor monitoring system are two monitors of radioactive material concentration in the air: The particles continuous monitor and the gaseous effluents monitor which present the referred information of the diverse detectors through ana logical readers. These monitors when operating with an ana logical indication does not present the possibility to generate historical files electronically of each monitor previously mentioned neither to generate visual and audible indications of the alarms. This work presents the Automated System of Area Radiation Measurement which potentiated the functionality of the area monitors for gamma and neutron radiation, as well as of the particles continuous monitor and the gaseous effluents of reactor TRIGA Mark III, when being developed a computer system that captures in real time the information of all the monitors, generating this way an electronic binnacle, a visual and audible alarm

  17. Exposición humana a las radiaciones electromagnéticas no ionizantes. Legislación y medidas de estaciones base

    Directory of Open Access Journals (Sweden)

    Alonso Alonso Alonso

    2004-12-01

    Full Text Available Este trabajo trata sobre los procedimientos de medida de las radiaciones no ionizantes y sus niveles registrados en medidas reales. Las fuentes de radiación analizadas cubren los medios de radiodifusión más corrientes, tales como las transmisiones AM y FM y también las estaciones base de telefonía móvil GSM. Estas fuentes habitualmente radian sobre áreas con alta densidad de población. Se describe brevemente el marco legal que regula los niveles de radiación en España y se señalan algunas posibles mejoras. Se valorarán los resultados encontrados en las medidas.

  18. Effect of UV radiation on the genetic inactivation of sperm of the bullseye puffer Sphoeroides annulatus (Jenyns, 1842); Efecto de la radiacion UV en la inactivacion genetica del esperma de botete diana Sphoeroides annulatus (Jenyns, 1842)

    Energy Technology Data Exchange (ETDEWEB)

    Arias-Rodriguez, Lenin; Rodriguez-Ibarra, Luz Estela; Del Valle-Pignataro, Gabriela [Laboratorio de Genetica, Centro de Investigacion en Alimentacion y Desarrollo, A. C., Sinaloa (Mexico)

    2004-09-15

    extendedora Cortland modificada en dilucion 1:50, y se utilizaron para probar el efecto de nueve dosis de radiacion ultravioleta (0.2-1.0 J cm{sup -}2 ) sobre la duracion de la motilidad en segundos, el indice de motilidad del esperma, y los porcentajes de superviviencia de embriones obtenidos de la fertilizacion de huevos provenientes de cinco hembras de la misma especie. Los tiempos de motilidad del esperma en las muestras irradiadas con 0.2-0.9 J cm{sup -}2 resultaron estadisticamente no diferentes de los controles, mientras que las muestras irradiadas con 1.0 J cm{sup -}2 fueron significativamente menores. El indice de motilidad (IM), por otra parte, permitio la diferenciacion estadistica de cuatro grupos en cuanto a su respuesta a diferentes dosis de radiacion. El primer grupo se caracterizo por valores altos del IM, e incluyo a los controles y a las muestras irradiadas con 0.2-0.3 J cm{sup -}2; el segundo agrupo a las irradiaciones de 0.4 a 0.7 J cm{sup -}2, en las cuales se observo un descenso del IM; en el tercer grupo (0.8-0.9 J cm{sup -}2 ) el IM aumento nuevamente; y en el ultimo (1.0 J cm{sup -}2) se observo el menor IM. En cuanto a los porcentajes de supervivencia, se observo una curva descendente con valores altos de supervivencia en los controles y en las muestras irradiadas con 0.2 J cm{sup -}2, con un descenso en los tratamientos de 0.3 a 0.4 J cm{sup -}2, y una recuperacion significativa a partir del tratamiento de 0.5 y hasta 0.8 J cm{sup -}2, observandose nuevamente un decremento en la supervivencia de los tratamientos de 0.9 a 1.0 J cm{sup -}2 . Ambos resultados, IM y supervivencia, indican que la dosis optima para la produccion de organismos haploides se encuentra cercana a 0.7 J cm{sup -}2. En el tratamiento de 0.7 J cm{sup -}2 se observaron larvas con las caracteristicas tipicas del sindrome haploide, indicando nuevamente que esta puede ser la dosis mas adecuada para producir organismos ginogeneticos.

  19. A new method for intraoperative localization of epilepsy focus by means of a gamma probe; Um novo metodo para a localizacao intraoperatoria de foco de epilepsia mediante utilizacao de gamaprobe

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro Filho, Omar, E-mail: dromarcarneiro@gmail.com [Centro Brasileiro de Medicina Nuclear e Imagem Molecular (CEBRAMEN), Goiania, GO (Brazil); Instituto de Medicina Nuclear, Goiania, GO (Brazil); Vilela Filho, Osvaldo [Universidade Federal de Goias (UFG), Goiania, GO (Brazil). Hospital das Clinicas. Servico de Neurocirurgia; Ragazzo, Paulo Cesar [Instituto de Neurologia de Goiania, GO (Brazil). Servico de Eplepsia e Neurofisiologia; Fonseca, Lea Mirian Barbosa da [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Dept. de Radiologia

    2014-01-15

    Objective: to evaluate the utility of a new multimodal image-guided intervention technique to detect epileptogenic areas with a gamma probe as compared with intraoperative electrocorticography. Materials and methods: two symptomatic patients with refractory epilepsy underwent magnetic resonance imaging, videoelectroencephalography, brain SPECT scan, neuropsychological evaluation and were submitted to gamma probe-assisted surgery. Results: in patient 1, maximum radioactive count was initially observed on the temporal gyrus at about 3.5 cm posteriorly to the tip of the left temporal lobe. After corticotomy, the gamma probe indicated maximum count at the head of the hippocampus, in agreement with the findings of intraoperative electrocorticography. In patient 2, maximum count was observed in the occipital region at the transition between the temporal and parietal lobes (right hemisphere). During the surgery, the area of epileptogenic activity mapped at electrocorticography was also delimited, demarcated, and compared with the gamma probe findings. After lesionectomy, new radioactive counts were performed both in the patients and on the surgical specimens (ex-vivo). Conclusion: the comparison between intraoperative electrocorticography and gamma probe-assisted surgery showed similarity of both methods. The advantages of gamma probe include: noninvasiveness, low cost and capacity to demonstrate decrease in the radioactive activity at the site of excision after lesionectomy. (author)

  20. Gamma teletopography

    International Nuclear Information System (INIS)

    Simonet, G.

    1986-09-01

    To set the gamma activity cartography is an important element of safety in numerous cases: intervention in hot cell, search of a radioactive source, examination of radioactive waste circuit followed by a reprocessing definition of decontamination and decommissioning processes and for all other accidents. The device presented here is like a ''black box'' with an aperture and an emulsion photosensitive to the opposite; a classical film takes photography of the place; a X-ray type emulsion gives a spot more or less contrasted and extensive corresponding to each source. Images can be processed with a microprocessor [fr

  1. Gamma knife

    International Nuclear Information System (INIS)

    Kawamoto, Shunsuke; Takakura, Kintomo

    1991-01-01

    As to the gamma knife which is the radiation surgery device developed in Sweden a quarter century ago, its principle, structure, treatment techniques, already established clinical effect and the problems being left for hereafter are described. This treatment means supplements the operation under microscopes, and at present it takes the important position in neurosurgery, but hereafter, by the interdisciplinary cooperation of neurosurgery and clinical radiobiology, the more development can be expected. The method of irradiating the radiation of high dose selectively to a target region and breaking its tissue is called radiosurgery, and the device developed for this purpose is the gamma knife. First, it was applied to functional diseases, but good results were obtained by its application to auditory nerve and brain blood vessels, and it establishes the position as the safe treatment method of the morbid state in the deep part of brains, which is difficult to reach by operation. Accompanying the recent progress of the operation of skull base part, attention is paid to its application to various tumors in skull base. On the other hand, the radiosurgery combining a cyclotron or a linear accelerator with stereotaxic brain surgery is actively tried mainly to the deformation of brain blood vessels. (K.I.)

  2. Chemical modification of high molecular weight polyethylene through gamma radiation for biomaterials applications; Modificacao quimica de polietileno de alto peso molecular atraves de radiacao gama para aplicacao em biomateriais

    Energy Technology Data Exchange (ETDEWEB)

    Raposo, Matheus P.; Rocha, Marisa C.G., E-mail: matheusmerlim@hotmail.com [Universidade Estado do Rio de Janeiro (UERJ), Nova Friburgo, RJ (Brazil). Instituto Politecnico

    2015-07-01

    Ultra high molecular weight polyethylene has been used in the medical field due to its high mechanical properties compared to the other polymers. Its main application is in the development of orthopedic implants, which requires high resistance to abrasion. One of the most used methods is the introduction of crosslinks in the polymer through gamma irradiation. In order to prevent oxidation reactions, studies have been developed using tacoferol (vitamin E) as an antioxidant for the material. The ascorbic acid (vitamin C), however, has been appointed as a viable alternative for vitamin E. In this work, a high molecular weight polyethylene grade (HMWPE) and polyethylene samples formulated with vitamin C were submitted to gamma radiation. Thermodynamic-mechanical methods and gel content determinations were used to characterize the samples obtained. The sample containing 1% of vitamin C and irradiated with 50 KGy of gamma radiation presented the highest content of crosslinks. (author)

  3. Gamma camera

    International Nuclear Information System (INIS)

    Tschunt, E.; Platz, W.; Baer, U.; Heinz, L.

    1978-01-01

    A gamma camera has a plurality of exchangeable collimators, one of which is mounted in the ray inlet opening of the camera, while the others are placed on separate supports. The supports are swingably mounted upon a column one above the other through about 90 0 to a collimator exchange position. Each of the separate supports is swingable to a vertically aligned position, with limiting of the swinging movement and positioning of the support at the desired exchange position. The collimators are carried on the supports by means of a series of vertically disposed coil springs. Projections on the camera are movable from above into grooves of the collimator at the exchange position, whereupon the collimator is turned so that it is securely prevented from falling out of the camera head

  4. Aplicación del análisis por activación neutrónica de gammas inmediatos (PGNAA) para el perfilaje de perforaciones de voladura en una cantera de Cementos Lima: Reporte Preliminar

    OpenAIRE

    Zanabria, César; Medina, Rafael; Gilvonio, Leoncio; Munive, Marco; Baltuano, Oscar; Solís, José

    2008-01-01

    El análisis por activación neutrónica de gammas inmediatos (PGNAA) es una técnica de análisis elemental que se usa en la industria. Estamos investigando la factibilidad de la aplicación de la técnica PGNAA en la caracterización elemental de las perforaciones de voladura de la cantera de Atocongo de Cementos Lima. The prompt gamma neutron activation (PGNAA) is a technique that has been used in the industry. We are investigating the feasibility of the PGNAA technique for elemental characteri...

  5. The Measurement of Integrated Gamma-Ray Doses in the Range 50 Mrad to 5 Mrad Using Phosphate Glass and Lithium Fluoride; Mesure, au Moyen de Verre au Phosphate et de Fluorure de Lithium, de Doses Integrees de Rayons Gamma de 50 Mrad a 5 Mrad; 0418 0417 041c 0414 ; Medicion de Dosis Integradas de Rayos Gamma de 50 Mrad a 5 Mrad por Medio de Vidrio al Fosfato y de Fluoruro de Litio

    Energy Technology Data Exchange (ETDEWEB)

    Webb, G. A.M. [Central Electricity Generating Board, Berkeley Nuclear Laboratories, Berkeley, Glos. (United Kingdom)

    1965-06-15

    'a pas fait l'objet de recherches aussi poussees. Le verre comme le fluorure de lithium peuvent etre recuits et reutilises, et l'auteur a essaye differents cycles de recuit pour chacun d'eux; il a egalement mesure la sensibilite en cas de reutilisation. Il a etudie pour chaque systeme les effets de la temperature d'irradiation et de la temperature d'entreposage entre 20 et 100 Degree-Sign C et a mesure les doses dans des flux mixtes de neutrons et de rayons gamma. L'auteur compare les deux systemes du point de vue de leurs usages generaux et de leurs possibilites d'application dans des cas particuliers. (author) [Spanish] Como base de sistemas dosimetricos para el intervalo de dosis de rayos y de 50 mrad a 5 Mrad, el autor ha comparado la radiofotoluminiscencia y la alteracion del color del vidrio al fosfato con la termoluminiscencia del fluoruro de litio. Midio la luminiscencia inducida en un vidrio al fosfato de bajo numero atomico, activado con plata, con ayuda de un fluorometro comercial (dosimetro Toshiba de vidrio fluorado) completado con- un espectrofotometro para medir las variaciones de la densidad optica en la region de las dosis elevadas. Estudio los efectos de diversos procedimientos para limpiar el vidrio. La termoluminiscencia del fluoruro de litio se midio con un aparato de lectura de laboratorio a fin de obtener curvas de luminosidad, integrandose seguidamente la superficie situada bajo el pico apropiado. El espectro de emision de la termoluminiscencia se determino empleando filtros opticoe que sirvieron tambien para reducir lo mas posible los efectos debidos a la radiacion infrarroja procedente de la placa calentadora. Se estudiaron los efectos ejercidos sobre el pico de tribotermoluminiscencia por los filtros opticos y por una atmosfera de nitrogeno. El funcionamiento de ambos sistemas se ha estudiado y comparado segun diversos criterios. El vidrio abarca un intervalo muy amplio, desde 5 * 10{sup -2} a 5 * 10{sup 6} rad, es decir, un intervalo dinamico

  6. Study on the energy dependence of gamma radiation detectors for {sup 137}Cs and {sup 60}Co; Estudo da dependencia energetica de detectores de radiacao gama para {sup 137}Cs e {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda B.C.; Diniz, Raphael E.; Carvalho, Valdir S.; Vivolo, Vitor; Caldas, Linda V.E., E-mail: fbnonato@ipen.b, E-mail: rediniz@ipen.b, E-mail: vcsouza@ipen.b, E-mail: vivolo@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    38 Geiger-Mueller radiation detectors and 9 ionization chambers were calibrated, viewing to study the energy dependence of the monitor response for gamma radiation fields ({sup 137}Cs and {sup 60}Co). The results were considered satisfactory only for ionization chambers and for some Geiger-Mueller detectors

  7. Development and implementation of an automated system for antiquated of the process of gamma radiation monitors calibration; Desenvolvimento e implantacao de um sistema automatizado para adequacao do processo de calibracao de monitores de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, Iremar Alves

    2012-07-01

    In this study it was carried out the development and implementation of a system for the appropriate process of gamma radiation monitors calibration, constituted by a pneumatic dispositive to exchange the attenuators and a positioning table, both actuated through a control panel. We also implemented a System of Caesa-Gammatron Irradiator, which increased the range of the air kerma rates, due to its higher activity comparing with the current system of gamma radiation in use in the calibration laboratory of gamma irradiation. Hence, it was necessary the installation of an attenuator dispositive remotely controlled in this irradiator system. Lastly, it was carried out an evaluation of the reduction in the rates of the occupational dose. This dissertation was developed with the aim of improving the quality of the services of calibration and tests of gamma radiation monitors - provided by the IPEN Laboratory of Instrument Calibration - as well as decreasing the occupational dose of the technicians involved in the process of calibration, following thus the principles of radiation protection. (author)

  8. Solar system design to heating water for a biodigester; Diseno de un sistema solar de calentamiento de agua para un biodigestor

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez Castro, Lucia Monica; Quinto Diez, Pedro [Escuela Superior de Ingenieria Mecanica y Electrica, Instituto Politecnico Nacional, Mexico, D.F. (Mexico)]. E-mail: moni-80-lgc@hotmail.com; pqd510@hotmail.com; Tovar Galvez, Luis Raul [Centro Interdisciplinario de Investigaciones de Estudios sobre Medio Ambiente y Desarrollo, Instituto Politecnico Nacional, Mexico, D.F. (Mexico)]. E-mail: ltovarg@ipn.mx

    2010-11-15

    In this paper a Solar System of Heating Water (SSHW) to provide energy to a biodigester which produces biogas located in the Interdisciplinary Center of Investigation of Studies About Environment and Development (CIIEMAD) is assessed. This evaluation is made by means of the f Method considerating the extraterrestrial radiation, the earth radiation in the zone and the necessary energy to maintain at 55 degrees Celsius the mixture inside the biodigester. The data were introduced in the SOLAR program to calculate both the harnessing area m{sup 2} and the storage capacity in L/m{sup 2}. To guarantee the good performance of the SSHW, a control and monitoring system for the temperature of the mix inside the biodigester is proposed. It also controls the input and output temperature to the solar collectors, as well as the cost analysis which shows the savings of fuel of the SSHW with a conventional system to heating water. [Spanish] En este articulo se evalua un sistema solar de calentamiento de agua (SSCA) para proveer energia a un biodigestor que forma parte del sistema de generacion de biogas (SGB) ubicado en el Centro Interdisciplinario de Investigaciones de Estudios sobre Medio Ambiente y Desarrollo (CIIEMAD). Dicha evaluacion se realiza por medio del Metodo f de diseno que considera datos de radiacion terrestre, radiacion extraterrestre sobre la zona y la energia necesaria para mantener la temperatura de la mezcla dentro del biodigestor a 55 grados centigrados. Los datos fueron introducidos en el programa SOLAR para el calculo del area de captacion en m{sup 2} y la capacidad de almacenamiento en L/m{sup 2}. Para garantizar el buen funcionamiento del SSCA se propone un sistema de control y monitoreo de la temperatura de la mezcla dentro del biodigestor. Tambien se controla la temperatura de entrada y salida a los colectores solares, asi como el analisis de costos que muestra el ahorro de combustible del SSCA con un sistema convencional de calentamiento de agua.

  9. Gamma camera

    International Nuclear Information System (INIS)

    Conrad, B.; Heinzelmann, K.G.

    1975-01-01

    A gamma camera is described which obviates the distortion of locating signals generally caused by the varied light conductive capacities of the light conductors in that the flow of light through each light conductor may be varied by means of a shutter. A balancing of the flow of light through each of the individual light conductors, in effect, collective light conductors may be balanced on the basis of their light conductive capacities or properties, so as to preclude a distortion of the locating signals caused by the varied light conductive properties of the light conductors. Each light conductor has associated therewith two, relative to each other, independently adjustable shutters, of which one forms a closure member and the other an adjusting shutter. In this embodiment of the invention it is thus possible to block all of the light conductors leading to a photoelectric transducer, with the exception of those light conductors which are to be balanced. The balancing of the individual light conductors may then be obtained on the basis of the output signals of the photoelectric transducer. (auth)

  10. Gamma ray generator

    Science.gov (United States)

    Firestone, Richard B; Reijonen, Jani

    2014-05-27

    An embodiment of a gamma ray generator includes a neutron generator and a moderator. The moderator is coupled to the neutron generator. The moderator includes a neutron capture material. In operation, the neutron generator produces neutrons and the neutron capture material captures at least some of the neutrons to produces gamma rays. An application of the gamma ray generator is as a source of gamma rays for calibration of gamma ray detectors.

  11. Beta-Excited Sources of Electromagnetic Radiation; Sources de rayonnements electromagnetiques excites par des particules beta; Vozbuzhdennye beta-chastitsami istochniki ehlektromagnitnogo izlucheniya; Fuentes de radiacion electromagnetica excitadas por particulas beta

    Energy Technology Data Exchange (ETDEWEB)

    Cameron, J F; Rhodes, J R [Physics Group, Isotope Research Division, (AERE), Wantage Research Laboratory, Wantage, Berks (United Kingdom)

    1962-01-15

    electromagneticas excitadas por particulas beta que abarcan el intervalo energetico de 1 a 200 keV y que resultan adecuadas para su uso en la industria. Como fuentes de particulas beta eligieron los isotopos {sup 3}H, {sup 147}Pm, {sup 85}Kr, {sup 204}Tl y {sup 90}Sr+{sup 90}Y, en razon de su largo periodo, reducido precio, facilidad de obtencion y elevada actividad especifica. En el diseno de las fuentes excitadas por particulas beta han procurado conciliar las exigencias practicas de la fabricacion con la necesidad de obtener un rendimiento teorico elevado en cierto intervalo energetico. En su memoria, los autores calculan el numero de fotones producido por particula beta y describen las correcciones que la autoabsorcion de los rayos X obliga a introducir en esos calculos, en que se tiene en cuenta a la vez la ''Bremsstrahlung'' y la radiacion a caracteristica; la emision maxima de radiaciones caracteristicas se observa en los blancos cuyo numero atomico este comprendido entre 40 y 60. Los autores comprueban que en el intervalo energetico de interes el mejor rendimiento fotonieo se obtiene con blancos ''sandwich'' cuyo semiespesor corresponde a 1 o 2 alcances beta. Desde el punto de vista de la fabricacion, el aluminio, la plata y el oro resultan, adecuados para el revestimiento de las fuentes. Se ha comprobado que esos metales proporcionan tambien resultados satisfactorios en lo relativo a la emision y distribucion de la ''Bremsstrahlung'' y de los rayos X para distintas gamas de energia en el intervalo de 1 a 200 keV, siempre que se combinen de forma adecuada con los emisores beta mencionados. Los autores proporcionan algunos espectros energeticos y curvas de absorcion en aluminio y en hierro correspondientes a las combinaciones fuente- blanco mas adecuadas. Han comprobado que la diferencia de comportamiento entre las fuentes constituidas por emisores beta intercalados entre laminas blanco y las mezclas intimas de fuente y blanco es pequena. A titulo de orientacion, los autores

  12. Effects produced by nuclear radiation in powdery milk; Efectos producidos por radiaciones nucleares en leches en polvo

    Energy Technology Data Exchange (ETDEWEB)

    Urena N, F; Reyes G, A [Instituto Nacional de Investigaciones Nucleares, A.P. 18-1027, 11801 Mexico D.F. (Mexico)

    1999-07-01

    The objective of this work is to determine the chemical effects produced by the gamma rays and beta particles radiations on the powdery milk. This work treats on the Pre-dose analysis, sampling radiating, electron spin resonance, acidity, proteins, aminoacids, lactose, fatty acids, peroxides, as well as its experimental results. (Author)

  13. Conjugate view gamma camera method for measuring activity in 131{sup I} treatments; Metodo de la imagen conjugada para la cuantificacion de la actividad en tratamientos de 131{sup I}

    Energy Technology Data Exchange (ETDEWEB)

    Barquero Sanz, R.; Placios, A. M.; Perez, D. M.; Tortosa Oliver, R.; Michel, R.

    2012-07-01

    A quantification method is developed to determine 131{sup I} activity and its associated uncertainty using regions of interest from gamma camera images. Inside a neck phantom, a known activity source is introduced to simulate thyroid remainders in thyroid differentiated cancer. The three parameters that define the accuracy of the method are: net count rates in ROI, the air calibration factor of the gamma camera and the attenuation correction factor. In order to obtain net count rates, four methods for background subtraction are tested. The best procedure to follow is based in two energy windows acquisitions, which gives an activity result of 47 {+-} 5 {mu}Ci Bq, in good agreement with the real activity value for the source, 46 {+-} 5 {mu}Ci. (Author) 12 refs.

  14. Systematic review and gamma radiosensitivity of medicinal plants: development of protocol for quality control; Revisao sistematica e radiossensitividade gama de plantas medicinais: desenvolvimento de protocolo para controle de qualidade

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Ralph Santos

    2006-07-01

    The present study discusses the contribution of the adoption of more rigorous and objective criteria to the selection and analysis of information sources, leading to more scientific rigour when registering phytotherapic drugs. To this end, it is herein proposed the adoption of a previously tested and acknowledged methodology, namely the Systematic Revision, as a standard for phytotherapic drug analyses. In order to show differences brought about by the Systematic Revision during the registration procedures of phytotherapic drugs, the case of the Maytenus ilicifolia (known popularly in Brazil as 'espinheira-santa') is presented. As it is well known, the use of ionizing radiation is expanding, especially in medicine and pharmacy. Therefore, gamma radiation was applied to the microbiological quality control of phytotherapic matrices. Results indicated a positive contribution of Systematic Revision to the registration procedures of phytotherapic drugs, as well as the advantages of using gamma radiation to the microbiological quality control of phytotherapic matrices. (author)

  15. Application of gamma irradiation for incorporation of rubber powder in the formulations EPDM and NBR rubber; Aplicacao da radiacao gama para incorporacao do po de borracha em formulacoes de borracha EPDM e nitrilica

    Energy Technology Data Exchange (ETDEWEB)

    Kiyan, Ludmila de Ysasa Pozzo

    2014-07-01

    The natural decomposition of rubber is a very slow process due to its three-dimensional network formed by vulcanized crosslinked structures becoming extremely difficult to reprocess this material. The present work aims to study the application of gamma irradiation as devulcanization process for material reuse/recycling. The interactions of elastomers with ionizing radiation of a gamma source were investigated and the changes in physicochemical properties of the materials were evaluated. Formulations of NBR (acrylonitrile - butadiene) and EPDM (ethylene - propylene - diene terpolymer) from the rubber industry were crosslinked by conventional sulfur-based mixing. Master - batch was processed with rubber powder (industrial waste) and virgin rubber. The raw material (master batch) was irradiated in {sup 60}Co source at doses of 50, 100, 150 kGy and dose rate of 5 kGy h{sup -1} at room temperature. The irradiated material was incorporated in classical sulfur-based formulations. The formulations were characterized by: infrared spectroscopy (FTIR), thermal analysis (TG and DTG), tensile strength, elongation at break, hardness, abrasion resistance, rheometry and swelling. The results showed a predominance of chain scission at a dose of 50 kGy for EPDM rubber. For nitrile predominance of chain scission was observed at a dose of 100 kGy. These results show the possibility of the use of gamma radiation for the reuse/recycling of EPDM and nitrile rubbers. (author)

  16. Determination of {sup 226}Ra by gamma spectrometry: study of packaging vial of sample for analysis; Determinacao de {sup 226}Ra por espectrometria gama: estudo do recipiente de acondicionamento de amostra para analise

    Energy Technology Data Exchange (ETDEWEB)

    Carneiro, Andre Cavalcanti

    2015-07-01

    Determination of radioactivity levels of {sup 226}Ra by gamma spectrometry in a sample is based on measurements of {sup 214}Pb and {sup 214}Bi, daughters of {sup 222}Rn. Because radon is a gas, it can leak from the sample vial or accumulate on the upper empty it. If the vial has any crack, there will be loss of gas, which will cause error in determining the {sup 226}Ra concentration. One possible cause of cracks in the vials, that houses standards and samples, is the radiolysis action in the vial material, usually a polymer. As the demand {sup 226}Ra analysis in different matrices (geological samples, food, plants, etc.) is increasing, it was decided to study some polymer vials available on the market, to verify the feasibility to be used when is applied the analysis method using gamma spectrometry. Four types of polymer vials have been studied. The radiation doses in walls of the vials caused by natural radionuclides present in the sample were simulated using gamma irradiation. Tests, such as compressive strength test and tightness, were applied to the irradiated and non-irradiated vials. First, to verify the effect of radiolysis on the vial material and also if there was {sup 222}Rn diffusion in their walls. These preliminary results pointed out that the acrylic vials are the best option of packaging samples for analysis. This study should be repeated in a larger number of samples for a better evaluation. (author)

  17. Guidelines on the medical therapy of persons accidentally overexposed to ionizing radiations. Internal contamination; Guia para el tratamiento de personas accidentalmente sobreexpuestas a las radiaciones ionizantes. Contaminacion interna

    Energy Technology Data Exchange (ETDEWEB)

    Di Trano, J L; Perez, M R; Gisone, P

    1999-07-01

    This work represent a guide for the treatment of accidental intakes of radionuclides. The different phases of radioactive contamination, the transfer and non-transfer of radioisotopes, the general principles in the treatment of internal contamination and the follow-up are determined. The in vivo monitoring and the evaluation of activity level are specified in this document. The applied treatment depends on the via of intake, that is: inhalation, ingestion, and through skin. The decontamination procedures that reduce the radionuclide transfer are specified. The different drugs, used to enhance radionuclides elimination, are enumerated in this work. Considerations about the iodine prophylaxis in radiologic als accidents are considered. (author)

  18. Development of tool for optimization in the measurement of solar radiation; Desarrollo de herramientas para la optimizacion en la medicion de la radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Adaro, J.; Quiroga, D.; Fasulo, A.; Lema, A.

    2004-07-01

    One of the most important requirements to make a project of rational use of solar energy is the precise knowledge of the temporal-spatial distribution of the solar resource on the terrestrial surface. For that reason, the Solar Energy Group at the National University of Rio Cuarto in Argentina, is measuring and recording data of global and direct solar radiation. Many possibilities of different kinds of errors there exist in this process, but the most significant problem is the lack of data. Then, it would be necessary to have a methodology that indicates what to do in this situation, and for that reason, this work performs an study about the data processing of the obtained measurements to infer values to be incorporated to the series in situations where the data are lost. To incorporate lost data, the Time Series Analysis based in spatial state models were used. (Author)

  19. Orintsol. Surfaces with assorted inclination: software to calculate the solar radiation; Orientsol. Superficies con distinta inclinacion Software para el calculo de la radiacion solar

    Energy Technology Data Exchange (ETDEWEB)

    Rus, C.; Almonacid, F.; Hontoria, L.; Perez, P. J.; Munoz, F. J.

    2009-07-01

    The Universidad de Jaen, conscious of the importance of using energy sources respectful with the environment, offers in its Technical Industry Engineer degree, in the specialties of: Mechanics, Electricity and Industrial electronics the optional subjects Solar electricity and Photovoltaic Facilities. With these matters is intended that the students acquire the capability of design, calculate, analyze their different applications. A fundamental aspect in solar facilities is how to know the incident radiation in the plant which we want to analyze or the size. Orintsol software tool, with a didactic aim, facilitates so teaching as learning about solar radiation received on inclined surfaces. (Author) 8 refs.

  20. Guidelines on the medical therapy of persons accidentally overexposed to ionizing radiations. External contamination; Guia para el tratamiento de personas accidentalmente sobreexpuestas a las radiaciones ionizantes. Contaminacion externa

    Energy Technology Data Exchange (ETDEWEB)

    Perez, M R; Di Trano, J L; Gisone, P

    1998-07-01

    The document represents a guide for the external decontamination of persons accidentally radio contaminated due to the use, production or transport of radioactive materials. The general conditions, from the medical point of view, to be kept in mind, in the event of accidental overexposures as decontamination treatment and the handling of samples are detailed throughout report. The external contamination without injury in skin or with wound its considered. The distribution of measures and responsibilities for the therapy of the irradiated patients with radioactive materials are enumerated. The preparations of decontaminate solutions are detailed in this work. Moreover, forms for the reception, physical evaluation of the patient and external contamination are presented. (author)

  1. Tools for assessing the environmental impact of ionizing radiation. Application on the stage of The Cabril; Herramientas para evaluar el impacto medio ambiental de las radiaciones ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Real, A.; Robles, B.; Cancio, D.

    2011-07-01

    To carry out assessments of potential radiological risk in the fauna and flora, it is necessary to have adequate tools for this purpose. During the last two decades several countries and institutions have developed various approaches and tools to help assess the environmental impact of ionizing radiation. The two most complete tools and have been used by organizations other than those who developed it are RESRAD-BIOTA and ERICA.

  2. H(10) due to radiation scattered in a 6 MV Linac for tomotherapy; H*(10) debida a la radiacion dispersada en un LINAC de 6 MV para tomoterapia

    Energy Technology Data Exchange (ETDEWEB)

    Vega C, H. R.; Esparza H, A. [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98060 Zacatecas, Zac. (Mexico); Garcia R, M. G. [Instituto Tecnologico y de Estudios Superiores de Monterrey, Campus Zacatecas, Calz. Pedro Coronel 16, Dependencias Federales, 98600 Guadalupe, Zacatecas (Mexico); Reyes R, E. [Universidad de Guanajuato, Campus Leon, Division de Ciencias e Ingenierias, Loma del Bosque 103, Col. Lomas del Campestre, 37150 Leon, Guanajuato (Mexico); Hernandez A, L. [Consejo Nacional de Ciencia y Tecnologia, CIBNOR, Mar Bermejo 195, Col. Playa Palo de Santa Rita, 23090 La Paz, Baja California Sur (Mexico); Rivera, T., E-mail: fermineutron@yahoo.com [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Calz. Legaria 694, Col. Irrigacion, 11500 Ciudad de Mexico (Mexico)

    2017-10-15

    In order to determine the environmental equivalent dose (H(10)), due to the radiation that is dispersed over the body of a patient, 100 thermoluminescent dosimeters (TLD) around 6 MV TomoLINAC were used. The characteristics of the tomotherapy have the disadvantage that the shielding of the bunker increases considerably and for its design validated parameters are used for the conventional Linacs. In order to determine H(10) due to scattered radiation, measurements were made in the vicinity of the isocenter, while the 6 MeV photon beam was applied on a phantom. Also, TLDs were placed on the walls of the bunker that remained for 7 days, where approximately 50 patients were treated per day. At points close to the isocenter, the H(10) has an angular distribution caused by the phantom shape. In the bunker walls the highest H(10) was observed in the primary barriers. In the labyrinth, the impact of the scattered radiation was observed when measuring a greater value of the environmental equivalent dose in the wall furthest from the isocenter compared to the point located closest to it. (Author)

  3. Radiative transfer model for estimation of global solar radiation; Modelo de transferencia radiativa para la estimacion de la radiacion solar global

    Energy Technology Data Exchange (ETDEWEB)

    Pettazzi, A.; Sabon, C. S.; Souto, G. J. A.

    2004-07-01

    In this work, the efficiency of a radiative transfer model in estimating the annual solar global radiation has been evaluated, over different locations at Galicia, Spain, in clear sky periods. Due to its quantitative significance, special attention has been focused on the analysis of the influence of visibility over the global radiation. By comparison of both estimated and measured global solar radiation along year 2002, a typical annual visibility series was obtained over every location. These visibility values has been analysed in order to identify patterns and typical values, in order to be used to estimate the global solar radiation along a different year. Validation was done over the year 2003, obtaining an annual estimation less than 10 % different to the measured value. (Author)

  4. Simulation of radiation transport using MCNP for a teletherapy machine; Simulacion del transporte de radiacion usando MCNP para una maquina de teleterapia

    Energy Technology Data Exchange (ETDEWEB)

    Flores O, F.E.; Mireles G, F.; Davila R, J.I.; Pinedo V, J.L.; Risorios M, C.; Lopez del Rio, H. [UAZ, Unidad Academica de Estudios Nucleares, 98068 Zacatecas (Mexico)

    2008-07-01

    The MCNP code is used to simulate the radiation transport taking as tools the transport physics of each particle, either photon, neutron or electron, and the generation of random numbers. Developed in the Los Alamos National Laboratory, this code has been used thoroughly with great success, because the results of the simulations are broadly validated with representative experiments. In the one present work the room of radiotherapy of the Institute Zacatecano of the Tumor it is simulated, located in the city of Zacatecas where one is Theratron 780C machine manufactured by MSD Nordion, with the purpose of estimating the contribution to the dose that would be received in different points of the structure, included three directly under the source. Three results of analytical calculations for points located at different distances from the source are presented, and they are compared against those obtained by the simulation. Its are also presented results for the simulation of 10 points more distributed around the source. (Author)

  5. Non controlled effect of ionizing radiations : involvement for radiation protection; Efectos no dirigidos de la radiacion ionizante: implicaciones para la proteccion radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Little, J. B.

    2005-07-01

    It is widely accepted that damage to DNA is the critical event on irradiated cells, and that double strand breaks are the primary DNA lesions responsible for the biological effects of ionizing radiation. This has lead to the long standing paradigm that these effects, be they cytotoxicity, mutagenesis or malignant transformation, occur in irradiated cells as a consequences of the DNA damage they incur. Evidence has been accumulating over the past decade, however, to indicate that radiation may induce effects that ar not targeted to the irradiated cells itself. Two non-targeted effects will be described in this review. The first, radiation-induced genomic instability, is a phenomenon whereby signals are transmitted to the progeny of the irradiated cell over many generations, leading to the occurrence of genetic effects such as mutations and chromosomal aberrations arising in the distant descendants of the irradiated cell. Second, the bystander effect, is a phenomenon whereby irradiated cells transmit damage signals to non-irradiated cells in a mixed population, leading to genetic effects arising in these bystander cells that received no radiation exposure. the model system described in this review involves dense monolayer cultures exposed to very low fluences of alpha particles. The potential implications of these two phenomena for the analysis of the risk to the human population of exposure to low levels of ionising radiation is discussed. (Author) 111 refs.

  6. The SOS system like model to study the response to the ionizing radiation; El sistema SOS como modelo para estudiar la respuesta a la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Serment G, J.; Brena V, M., E-mail: jorge.serment@inin.gob.m [ININ, Departamento de Radiobiologia, Laboratorio de Genetica Microbiana, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2010-07-01

    One of the important aspects in the radiobiology is the study of the strategies that the alive beings follow to counteract the genetic lesions generated by ionizing radiation. Among these is the SOS response of the bacteria, a group of 60 genes approximately that is activated when they happen lesions in the DNA and whose causes and structural diversity are multiple. So, an interest point in this response is to elucidate as all this lesions diversity activates this response in turn since, the protein that begins the process only recognizes simple ruptures of the double helix. For this is comes off that in the great majority of the cases is required of a previous prosecution of the damages so that the structure is generated that shoots this system. In this work a brief summary of the contributions in this field is made by part of the Microbiology Laboratory of the Instituto Nacional de Investigaciones Nucleares (ININ). (Author)

  7. Biological assay of chromatin dispersal simplified for determining absorbed dose of ionizing radiation; Ensayo biologico simplificado de dispersion de cromatina para la determinacion de dosis de radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Galaz, S.; Perez, G.; Stockert, J. C.; Blazquez-Castro, A.

    2011-07-01

    Currently, the production of nuclear halos chromatin dispersion methods is a good procedure for nuclear analysis by in situ hybridization (Wiegant et al., 1992, Gerdes et al. 1994), to detect apoptosis, DNA fragmentation and cell death rates in cell cultures (Fernandez et al., 2005, Enciso et al. 2006). It is customary to display the nuclear halos by fluorescence microscopy using propidium iodide, ethidium bromide or DAPI (Gerdes et al., 1994, Sestili et al. 2006). Using this technique based on a modified protocol of fast halo assay [FHA],(Sestili et al. 2006), has developed a simplified method to quantify the cytogenetic damage induced by ionizing radiation (dispersion test chromatin in agarose thin smear), which allows visualization of halos after staining for light microscopy or fluorescence and correlating the ratio: total area occuped by the halo nucleus / nucleus (halo-core index [IHN] ) with radiation dose.

  8. Obtention of a thermoluminescent material for dosimetry of ionizing radiation; Obtencion de un material termoluminiscente para dosimetria de la radiacion ionizante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez M, P R

    1990-07-01

    The thermoluminescent dosemeters are small crystals which suffer changes in their structure by the radiation effect, being displaced the electrons toward higher energy levels. On heating the previously irradiated crystals, the electrons come back to their base state emitting light photons. The light quantity emitted is proportional to the received radiation dose. The light quantity emitted is proportional to the received radiation dose. The lithium fluoride is one of the thermoluminescent materials considered as tissue equivalents by having a low effective atomic number (Z{sub ef}). At present, the more used commercial product used of this type is the TLD-100*. In this work the obtained results in the preparation of the lithium fluoride thermoluminescent material are presented. This is activated with magnesium (Mg) and titanium (Ti), which we have labelled as: LiF: Mg, Ti. The results from the tests performed for verifying his thermoluminescent properties are presented too, as powder form as in pellets form. These tests were performed in simultaneous form with TLD-100 samples, which is considered as reference. The LiF: Mg, Ti thermoluminescent material manufactured in the ININ presents similar dosimetric characteristics to those ones of the TLD-100. Therefore being able to replace the imported dosemeters. * (TLD-100 is a commercial trademark registered by Harshaw/Filtrol (US) for LiF: Mg, Ti Tl dosemeters) (Author)

  9. Systematic for assessment of occupational exposure to ultraviolet radiation; Sistematica para la valoracion de la exposicion laboral frente a radiaciones ultravioletas

    Energy Technology Data Exchange (ETDEWEB)

    Anies Escartin, J.; Perramon Llado, A.

    2011-07-01

    The approval of Royal Decree 486/2010 of 23 April on the protection of health and safety of workers from risks related to exposure to artificial optical radiation, moves to state law a framework of protection against the radiation. This should involve a significant intensification of control at work is conducted in this radiation. Despite the complexity of the issue and limit values ??difficult to apply (for incoherent ultraviolet radiation enters the bounding box up to 5 different values ??may apply), requires a systematic analysis of the problem well done. In this paper we consider the ultraviolet radiation generated by artificial sources.

  10. Determination of optimal doses of radiation for the plant breeding of pseudo cereals; Determinacion de dosis optimas de radiacion para el mejoramiento de seudocereales

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, J [ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico); Gomez P, L [Universidad Nacional Agraria La Molina, Lima (Peru)

    2005-07-01

    With the purpose of promoting the use of the radiations for the plant breeding of pseudo cereals, it was determined a simple and economic method that allows the quick selection of radiation dose that induce in the vegetable organisms the changes wanted. For it it was work with quinua seeds (Chenopodium quinoa Willd.) an Andean pseudo cereal that, due to their nutritious and physiologic characteristics it is considered by the FAO like one of the foods of the future and for the NASA like an organism that is good to remove the carbon dioxide from the atmosphere and at the same time, to generate food, oxygen and water for the crew during the space missions of long duration and that it has already improved by means of the radiation application. The proposed method consists on the evaluation, of the embryonic structures (radicule, hypocotyl and cotyledons) in the irradiated seeds as well as of the development of root, primary shaft and true leaves in the plants. The changes in the growth, form, number and color of the structures as well as the time of appearance of each one, allow to predict the morphological changes and inclusive some physiologic ones that will have the mature organisms, so that in only three weeks it is possible to select the doses more appropriate. (Author)

  11. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011

    International Nuclear Information System (INIS)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia

    2013-01-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements

  12. Study of the radiation and radioactivity in dairy formulas; Estudio de la radiacion y radiactividad en formulas lacteas

    Energy Technology Data Exchange (ETDEWEB)

    Mireles G, F.; Pinedo V, J.L.; Quirino T, L.L.; Davila R, J.I.; Rios M, C.; Leal A, B.; Lopez del Rio, H. [Unidad Academica de Estudios Nucleares, UAZ, Cipres 10, Frac. La Penuela, 98068 Zacatecas (Mexico)]. e-mail: fmireles@cantera.reduaz.mx

    2006-07-01

    The radiation and natural radioactivity is present in the man's food chain, like it is the case of the milk, and it comes from the natural series of radioactive decay of the {sup 238} U, {sup 235} U and {sup 232} Th, and of the {sup 40} K radioisotope. Since the radioisotopes can be found in floor of where its are transferred to the grasses and in the water that serve as food and of drinking to the cows, then to enter the milk and its derived to the human consumption. In this work it is presented the study of the radiation and gamma radioactivity of 40 samples of dairy formulas of the trademarks and presentations more sold in the market of the private and public sectors. The measurements of the gamma ray spectra were carried out with a spectrometry system based on an Hyper pure Germanium detector (HPGe). The detector has a resolution (FWHM) of 1.9 keV for an energy of the gamma ray of 1.332 keV of the {sup 60} Co. This study presents the results of the concentration in activity of dairy formulations of the radioisotopes of interest. Also, the results are related with possible damages to the health. (Author)

  13. Application of gamma radiation on disinfestation feed grain based food for domestic animals; Aplicacao da radiacao gama na desinfestacao de racoes a base de graos para alimentacao de animais domesticos

    Energy Technology Data Exchange (ETDEWEB)

    Ramos, Amanda Cristina Oliveira

    2009-07-01

    This study aimed to realize a survey to identify the associated insects to feed the city Sao Paulo / SP and also to assess the effect of gamma radiation on food ration for domestic animals infested by pests. Samples of 20 stores, 'Pet Shop' in different regions in Sao Paulo / SP were subjected to trials of 1 and 45 days for collection of insects with the aid of plastic tray and screens of different sizes. The species Sitophilus zeamais, Cryptolestes ferrugineus, Lasioderma serricorne and Oryzaephilus sp. showed a higher frequency. In assessing the effects of gamma radiation we used samples of maize, sunflower seeds and mix for rodents infested with adults of the species Sitophilus zeamais, Lasioderma serricorne and Plodia interpunctella, after the period of 7 to 10 days the insects were removed and samples subjected to increasing doses of gamma radiation. The species Sitophilus zeamais and Lasioderma serricorne subjected doses from 0,25 to 1,50 kGy and species Plodia interpunctella doses from 0,10 to 2,0 kGy. After 40 days of irradiation was evaluated the number of insects emerged. The results of bioassays with Sitophilus zeamais and with Lasioderma serricorne demonstrated that doses starting at 0,5 kGy was sufficient to cause mortality of eggs and newly emerged larvae. The results with Plodia interpunctella from the 1,5 kGy, hasn't emerged adult insects, concluding that these doses were sufficient to cause mortality of eggs and larvae. (author)

  14. Cosmic gamma bursts

    International Nuclear Information System (INIS)

    Ehstulin, I.V.

    1980-01-01

    A brief consideration is being given to the history of cosmic gamma burst discovery and modern knowledge of their properties. The time dependence of gamma bursts is described and their possible sources are discussed

  15. Co60 and Cs137 gamma radiation effects on textured bscco Superconducting fibers

    International Nuclear Information System (INIS)

    Leyva Fabelo, A.; Bouza Dominguez, J.; Cruz Inclan, Crlos M.

    2001-01-01

    Bi2Sr2CaCu2Ox superconducting fibers synthesized by solid state reaction and textured by the method of zonal laser ablation were irradiated with gamma rays of 1.25 MeV and 662 keV and studied the behavior of some of its properties with the exposition dose. The measurements of dynamic magnetic susceptibility were used for the characterization of the samples. It was observed that for the dose of up to 600 kGy in the case of the Co60 and until 500 mGy for the Cs137, the fibers preserve its superconducting intragrain properties. It is an evidence of the high resistance of the material to the radiacional damage. In all the cases were verified that with the increase of the dose the Ton of the transition grows. Two possible mechanisms that play the most important role in this effect are explained in the text. The ac measurements allowed to verified the increasing behavior of the superconducting volume fraction in the sample with the exposition dose

  16. Catalytic Activity and Nuclear Radiation; L'activite catalytique et les rayonnements nucleaires; Kataliticheskaya aktivnost' i yadernoe izluchenie; La actividad catalitica y las radiaciones nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Turkevich, J.; Ikawa, T.; Nozaki, F.; Stamires, D. [Princeton University, N.J (United States)

    1963-11-15

    remplacant en partie l e sodium d'un tamis moleculaire du type Linde Y (Na{sub 56}(AlO{sub 2}){sub 56}(SiO{sub 2}){sub 126}) par l'ion ammonium pour l e decomposer ensuite de maniere a retirer a la fois l'ammoniaque et l'eau, ce qui cree des sites depourvus d e cations dans le tamis. Ils ont prepare une serie de ces catalyseurs possedant des nombres regulierement croissants de sites decationises (de 0 a 100%par rapport a la teneur primitive en sodium). Ils ont etudie l'activite catalytique de ces deux series de catalyseurs avant et apres exposition aux rayons gamma, en observant ia cinetique de la decomposition du cumene en benzene et propylene, l'isomerisation du butene - 1 en butene-2 par deplacement de la double liaison et la reaction d'echange hydrogene-deuteriu'm. Le nombre des sites actifs a ete determine par empoisonnement progressif a la quinoleine; on a donc pu chiffrer l'activite par site. Les auteurs ont aussi etudie ces substances en mesurant la resonance de spin des electrons pour des agents de transfert des electrons adsorbes, notamment la triphenylamine, le perylene et le diphenylethylene symetrique. Ils ont constate que la capacite de transfert des electrons est parallele a l'activite catalytique. lis ont pris la resonance protonique de l'eau absorbee pour caracteriser la nature du site catalytique. (author) [Spanish] Los autores exponen los resultados de nuevos trabajos acerca de los efectos de los rayos gamma sobre la actividad catalitica de un gel de silice y alumina y sobre tamices moleculares descationizados del tipo Linde Y. A tal efecto, prepararon una serie graduada de catalizadores de gel de silice y alumina coprecipitados, con diez distintos valores equidistantes para la razon atomica alumina/silice. Otra serie de catalizadores se obtuvo sustituyendo parcialmente el sodio de un tamiz molecular Linde Y, Na{sup 56}(AlO{sub 2}){sub 56}(SiO{sub 2}){sub 126}, por el ion amonio y descomponiendolo despues para expulsar tanto el amonio como el agua, con lo

  17. The principle of justification as a humanization of common sense. An approach to the ethics of medical indications with ionizing radiation; El principio de justificación como humanización del sentido común. Un acercamiento a la ética de las indicaciones médicas con radiaciones ionizantes

    Energy Technology Data Exchange (ETDEWEB)

    Arranz y Carrillo de Albornoz, L.

    2016-07-01

    The great difficulty for the prescriber to select a correct diagnostic imaging strategy is the large number of available scanners (there are over 800). The choice should be based on an aphorism of great tradition in medicine: First Do No Harm. Unfortunately many of the scans requested are not justified. According to the SERAM, up to 30% of the tests requested do not provide relevant information and many could be avoided and therefore patients were unnecessarily exposed to radiation. There is, therefore, an ethical responsibility the prescribing physician and the specialist physician of performing the examination or treatment, as well as by all the involved staff. Given the international consensus about the evidence of the effects of ionizing radiation, the ICRP summarized the scientific basis of this consensus with ethical and social sense and proposed the Radiation Protection System whose first principle is the justification. This system is based, apart from the well established scientific evidence and experience, on universally shared ethical values. It is necessary that the physicians could base their decision making on a procedure with ionizing radiation by having good formation, good experience, the best scientific knowledge and, above all, taking account the patient, respecting him, listening him and seeking their good. [Spanish] La gran dificultad que tiene el médico prescriptor para seleccionar una correcta estrategia diagnóstica de imagen es la gran cantidad de exploraciones disponibles (existen más de 800). La elección debe estar basada, en un aforismo de enorme tradición en medicina: primum non nocere. Lamentablemente muchas de las exploraciones solicitadas no están justificadas. De acuerdo con la SERAM, hasta un 30% de las pruebas solicitadas no aportan información relevante y muchas podrían haberse evitado y por lo tanto han expuesto innecesariamente a los pacientes a la radiación. Existe, por lo tanto, una responsabilidad ética tanto por

  18. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Broomhead, Laurent.

    1980-01-01

    The nuclear gamma astronomy is presented, in particular the Gamma Ray Observatory, an enormous eight tonnes machine fitted with gamma telescopes, scheduled for launching around 1985. It is thereby hoped to study the natural nuclear reactions which occur when stars explode [fr

  19. A NIM (Nuclear Instrumentation Module) system conjugated with optional input for pHEMT amplifier for beta and gamma spectroscopy; Um sistema de modulos NIM conjugados com entrada opcional por amplificador pHEMT para espectroscopia beta e gama

    Energy Technology Data Exchange (ETDEWEB)

    Konrad, Barbara; Lüdke, Everton, E-mail: barbarakonradmev@gmail.com, E-mail: eludke@smail.ufsm.br [Universidade Federal de Santa Maria (LAE/UFSM), RS (Brazil). Lab. de Astrofisica e Eletronica

    2014-07-01

    This work presents a high speed NIM module (Nuclear Instrumentation Module) to detect radiation, gamma and muons, as part of a system for natural radiation monitoring and of extraterrestrial origin. The subsystem developed consists of a preamplifier and an integrated SCA (Single Channel Analyzer), including power supplies of ± 12 and ± 24V with derivations of +3.6 and ± 5V. The single channel analyzer board, consisting of discrete logic components, operating in window modes, normal and integral. The pulse shaping block is made up of two voltage comparators working at 120 MHz with a response time > 60 ns and a logic anticoincidence system. The preamplifier promotes a noise reduction and introduces the impedance matching between the output of anode / diode photomultiplier tubes (PMTs) and subsequent equipment, providing an input impedance of 1MΩ and output impedance of 40 to 140Ω. The shaper amplifier is non-inverting and has variable input capacitance of 1000 pF. The upper and lower thresholds of the SCA are adjustable from 0 to ± 10V, and the equipment is compatible with various types of detectors, like PMTs coupled to sodium iodide crystals. For use with liquid scintillators and photodiodes with crystals (CsI: Tl) is proposed to include a preamplifier circuit pHEMT (pseudomorphic High Electron Mobility Transistor) integrated. Yet, the system presents the possibility of applications for various purposes of gamma spectroscopy and automatic detection of events producing of beta particles.

  20. Possibilities for standardization of {sup 152}Eu by liquid scintillation and gamma spectrometry; Possibilidades para padronização do {sup 152}Eu por cintilação líquida e por espectrometria gama

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira Filho, A.L.; Cruz, P.A.L. da; Silva, R.L. da; Delgado, J.U., E-mail: alfredo@ird.gov.br [Instituto de Radioproteção e Dosimetria (LNMRI/IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiações Ionizantes; Lopes, R.T. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (LIN/PEN/COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Lab. de Instrumentação Nuclear

    2017-07-01

    The {sup 152}Eu has a half-life of 13.5 years and a very complex decay scheme with two branches of decay. It disintegrates in {sup 152}Sm by electronic capture (72.1%) or by emission of positrons (0.027%) and in {sup 152}Gd by beta emission minus (27.9%). The child nucleus, {sup 152}Sm, has 19 excited levels, while {sup 152}Gd has 15. The direct decay of the parent nucleus to the fundamental state of the child nucleus does not exist. The decay of a {sup 152}Eu source results in emissions of 4 KX photons and 132 gamma rays, which is the reason for a lot of true coincidence-sum. The particular interest in this radionuclide is explained by its wide use in the calibration in energy and efficiency of gamma spectrometers with semiconductor detectors, since the range of energy of the emitted photons, varying from 40 to 1769 keV. But, because of such a complex decay scheme, the determination of {sup 152}Eu activity presents many difficulties. The CIEMAT / NIST liquid scintillation counting method and the peak-sum coincidence method, an absolute measurement technique using coincidence counts and photon spectrometry, have been tested in the LNMRI-IRD to standardize {sup 152}Eu solutions.

  1. New routes of preparation of polyaniline films and dosimetric characterization for high-doses gamma radiation; Novas rotas de preparacao de filmes de polianilina e caracterizacao dosimetrica para radiacao gama em altas doses

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Ana Paula Lima

    2003-08-15

    This work presents a new conducting polymeric material based on polyaniline thin films that will be used in the confection of dosimetric devices. On preparation of the films a homogeneous and viscous solution of poly (acrylic acid) and MnO{sub 2} is deposited on PMMA surface, which after dried, is immersed in an acid aniline solution. The films formed present low resistivity (6.10{sup 2} {omega}m), good mechanical resistance and adherence on the electrodes. The films were characterized by infrared spectroscopy, conductivity measurements and manganese elemental analyses. The resistance variations show linear correlation (r{sup 2} = 0,9928) with gamma irradiation dose in the range of 1000 to 6000 Gy, with medium error less than 5% and sensitivity response. The dosimetric devices present as advantage real time measurements, low cost, use in calibration of industrial radioactive sources. Moreover, this composite could in future replace Fricke dosimeter and its applications. A calibration curve is showed for PANI dosimeter, here proposed, to use at high gamma doses. (author)

  2. Poly(vinylidene fluoride) modification induced by gamma irradiation for application as ionic polymer-metal composite; Modificacao de poli(fluoreto de vinilideno) induzida por radiacao gama para aplicacao como composito ionomerico de metal-polimero

    Energy Technology Data Exchange (ETDEWEB)

    Ferreira, Henrique Perez

    2011-07-01

    Gamma-radiation-induced grafting of styrene into poly(vinylidene fluoride) (PVDF) films with 0.125 mm thickness at doses from 1 to 100 kGy in the presence of a styrene/N,N- dimethylformamide (DMF) solution (1:1, v/v) and styrene/toluene (1:1, v/v) at dose rate of 5 kGy h-1 was carried out by simultaneous method under nitrogen atmosphere at room temperature, using gamma rays from a Co-60. After grafting reactions, the polymer was then sulfonated in chlorosulfonic acid/1,2-dichloroethane (2 and 10%) for 3 hours. The films were characterized before and after modification by calculating the degree of grafting (DOG), infrared spectroscopy (FT-IR), scanning electron microscopy (SEM), differential scanning calorimetry (DSC) and thermogravimetry (TG/DTG). DOG results show that grafting increases with dose, and varies enormously depending on the solvent used, with DOGs about 20 times greater in DMF than in toluene. It was possible to confirm the grafting of styrene by FT-IR due to the appearance of the new characteristic peaks and by the TG and DSC which exhibited changes in the thermal behavior of the grafted/sulfonated material. Sulfonated material was also characterized by ion exchange capacity (IEC) showed that both DOG and sulfonic acid concentration increase IEC values. Results showed that it is possible to obtain materials with ion exchange capacity of possible application as ionic polymer-metal composites. (author)

  3. Reactor gamma spectrometry: status

    International Nuclear Information System (INIS)

    Gold, R.; Kaiser, B.J.

    1979-01-01

    Current work is described for Compton Recoil Gamma-Ray Spectrometry including developments in experimental technique as well as recent reactor spectrometry measurements. The current status of the method is described concerning gamma spectromoetry probe design and response characteristics. Emphasis is given to gamma spectrometry work in US LWR and BR programs. Gamma spectrometry in BR environments are outlined by focussing on start-up plans for the Fast Test Reactor (FTR). Gamma spectrometry results are presented for a LWR pressure vessel mockup in the Poolside Critical Assembly (PCA) at Oak Ridge National Laboratory

  4. Fabrication and electrical characterization of polyaniline-silicon heterojunction for gamma radiation dosimetry application; Fabricacao e caracterizacao eletrica de heterojuncoes de polianilina - silicio para aplicacao em dosimetria de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laranjeira, Jane Maria Goncalves

    2004-08-15

    In this work a technique has been developed to fabricate high quality polyaniline-silicon heterojunction diodes for use as gas and/or ionizing radiation sensors. Polyaniline thin films (40 nm thick) produced by spin-coating on silicon substrates, were the active part of the junction structure. The devices presented excellent reproducibility of their electrical characteristics with high rectification ratio, 60,000 at {+-}1.0 V, and typical reverse current at - 1.0 V of 3 nA at 295 K. A G/I x G plot has been used to analyze the current-voltage characteristics, yielding typical series resistance of 4 k{omega} {+-} 5% and ideality factor in a range of 1,9 {+-} 0.5%. The heterojunction diode presents high sensitivity to gamma radiation in the dose range of 3 x 10{sup -2} to 7 kGy with a linear response in the forward and reverse bias. The excellent electrical characteristics together with the linear response with the dose, strongly suggest the application of this device for spectrometry or dosimetry of high doses of gamma radiation. These devices presented high sensitivity to gas moistures such as ammonia, nitric acid and trichloroethylene. In both cases the sensitivity was observed through shifts of the current-voltage curves, which can be easily monitored to provide a calibration curve of the sensor either as a radiation dosimeter or as a gas sensor for use in applications for gas monitoring or radiation dosimetry. Several aspects of the reliability physics of silicon-polyaniline heterojunction, such as degradation effects induced by local heating, charge trapping and temperature changes, have been discussed. These results further confirm the quality of the devices electrical characteristics and their suitability for radiation and gas sensors applications. Another interesting results presented in this work was the use of polyemeraldine nanofilms (thickness in the range 30-50 nm) deposited by 'spin coating' on glass substrates as an optical dosimeter for gamma

  5. Fabrication and electrical characterization of polyaniline-silicon heterojunction for gamma radiation dosimetry application; Fabricacao e caracterizacao eletrica de heterojuncoes de polianilina - silicio para aplicacao em dosimetria de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Laranjeira, Jane Maria Goncalves

    2004-08-15

    In this work a technique has been developed to fabricate high quality polyaniline-silicon heterojunction diodes for use as gas and/or ionizing radiation sensors. Polyaniline thin films (40 nm thick) produced by spin-coating on silicon substrates, were the active part of the junction structure. The devices presented excellent reproducibility of their electrical characteristics with high rectification ratio, 60,000 at {+-}1.0 V, and typical reverse current at - 1.0 V of 3 nA at 295 K. A G/I x G plot has been used to analyze the current-voltage characteristics, yielding typical series resistance of 4 k{omega} {+-} 5% and ideality factor in a range of 1,9 {+-} 0.5%. The heterojunction diode presents high sensitivity to gamma radiation in the dose range of 3 x 10{sup -2} to 7 kGy with a linear response in the forward and reverse bias. The excellent electrical characteristics together with the linear response with the dose, strongly suggest the application of this device for spectrometry or dosimetry of high doses of gamma radiation. These devices presented high sensitivity to gas moistures such as ammonia, nitric acid and trichloroethylene. In both cases the sensitivity was observed through shifts of the current-voltage curves, which can be easily monitored to provide a calibration curve of the sensor either as a radiation dosimeter or as a gas sensor for use in applications for gas monitoring or radiation dosimetry. Several aspects of the reliability physics of silicon-polyaniline heterojunction, such as degradation effects induced by local heating, charge trapping and temperature changes, have been discussed. These results further confirm the quality of the devices electrical characteristics and their suitability for radiation and gas sensors applications. Another interesting results presented in this work was the use of polyemeraldine nanofilms (thickness in the range 30-50 nm) deposited by 'spin coating' on glass substrates as an optical dosimeter for

  6. GammaWorkshops Proceedings

    International Nuclear Information System (INIS)

    Ramebaeck, H.; Straelberg, E.; Klemola, S.; Nielsen, Sven P.; Palsson, S.E.

    2012-01-01

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  7. Preparation of PtRu/C anode electrocatalysts using gamma radiation for methanol electro-oxidation; Preparacao de eletrocatalisadores PtRu/C utilizando radiacao gama para aplicacao como anodo na oxidacao direta de metanol

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Dionisio Fortunato da

    2006-07-01

    Pt Ru/C (carbon-supported Pt Ru nanoparticles) anode electrocatalysts were prepared using radiolytic process (gamma radiation) and tested for methanol electro-oxidation. In this process, water/2-propanol and water/ethylene glycol solutions containing the metallic ions and the carbon support were submitted to gamma radiation under stirring. The water/alcohol ratio (v/v) and the total dose (kGy) were studied. A nominal Pt Ru atomic ratio of 50:50 were used in all experiments. The electrocatalysts were characterized by energy dispersive X-ray analysis (EDX), X-ray diffraction (XRD), transmission electron microscopy (TEM) and cyclic voltammetry (CV). The electro-oxidation of methanol was studied by cyclic voltammetry using the thin porous coating technique. The electrocatalysts prepared in water/2-propanol showed crystallite size in the range of 3-5 nm and Pt Ru atomic ratio of 50:50. The electrocatalysts prepared in water/ethylene glycol showed crystallite size (2-3 nm) smaller than the ones obtained in water/2-propanol, however, the Pt Ru atomic ratios obtained were approximately 80:20, showing that only part of ruthenium ions were reduced. For methanol oxidation the electrocatalytic activity depends on the water/2-propanol and water/ethylene glycol ratio used in the reaction medium. The electrocatalysts prepared in water/2-propanol showed inferior performance to the ones prepared in water/ethylene glycol, which showed similar or superior performances (amperes per gram of platinum) to the commercial electrocatalyst from E-TEK. (author)

  8. Validation of mathematical models to describe fluid dynamics of a cold riser by gamma ray attenuation; Validacao de modelos matematicos para descrever a fluidodinamica de um riser utilizando atenuacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Melo, Ana Cristina Bezerra Azedo de

    2004-12-15

    The fluid dynamic behavior of a riser in a cold type FCC model was investigated by means of catalyst concentration distribution measured with gamma attenuation and simulated with a mathematical model. In the riser of the cold model, MEF, 0,032 m in diameter, 2,30 m in length the fluidized bed, whose components are air and FCC catalyst, circulates. The MEF is operated by automatic control and instruments for measuring fluid dynamic variables. An axial catalyst concentration distribution was measured using an Am-241 gamma source and a NaI detector coupled to a multichannel provided with a software for data acquisition and evaluation. The MEF was adapted for a fluid dynamic model validation which describes the flow in the riser, for example, by introducing an injector for controlling the solid flow in circulation. Mathematical models were selected from literature, analyzed and tested to simulate the fluid dynamic of the riser. A methodology for validating fluid dynamic models was studied and implemented. The stages of the work were developed according to the validation methodology, such as data planning experiments, study of the equations which describe the fluidodynamic, computational solvers application and comparison with experimental data. Operational sequences were carried out keeping the MEF conditions for measuring catalyst concentration and simultaneously measuring the fluid dynamic variables, velocity of the components and pressure drop in the riser. Following this, simulated and experimental values were compared and statistical data treatment done, aiming at the required precision to validate the fluid dynamic model. The comparison tests between experimental and simulated data were carried out under validation criteria. The fluid dynamic behavior of the riser was analyzed and the results and the agreement with literature were discussed. The adopt model was validated under the MEF operational conditions, for a 3 to 6 m/s gas velocity in the riser and a slip

  9. English; Evaluacion de la dosis efectiva annual debido a fuentes ambientales de radiacion en la Provincia de Holguin, Cuba

    Energy Technology Data Exchange (ETDEWEB)

    Brigido Flores, Osvaldo; Barreras Cabellero, Aldo A.; Montalvan Estrada, Adelmo [Laboratorio de Vigilancia Radiologica Ambiental de Camaguey (Cuba)]. E-mail: sean@caonao.cmw.inf.cu; Hernandez Perez, Alberto; Tamayo, Luis Perez; Parra Valdes, Dermidio; Bravo Lopez, Rosendo [Centro de Atencion a la Actividad Nuclear, Holguin (Cuba); Zerquera, Juan Tomas [Centro de Proteccion y Higiene de las Radiaciones, La Habana (Cuba)

    2001-07-01

    A survey program aiming at studying the natural radioactivity in the Province of Holguin is a part of the national program carried out for 3 years. Radiological measurements carried out with a portable ionization chamber RSS-111 and RSS-112 at the sampled sites revealed an average outdoor absorbed dose rate of 43.5 nGy.h{sup -1} due to cosmic rays and terrestrial gamma radiation. Ratio of indoor to outdoor absorbed dose rates in air was 1.6. The average value of absorbed dose rate in air for the ionizing component of cosmic rays was 31.9 nGy.h{sup -1} at sea level. Because of the 82% of the Holguin population lives at altitudes close to sea level (10-200 m), the absorbed dose rate in outdoor air from ionizing component of cosmic rays was estimated to be 33.8 nGy.h{sup -1}. An annual average effective dose equivalent of 340 {mu}Sv was estimated for Holguin population due to the ionizing component of cosmic and gamma terrestrial radiation. This value is lower the 510 {mu}Sv.year{sup -1} estimated for the Camaguey population and lower than the 760 {mu}Sv.year{sup -1} estimated as a world average by UNSCEAR (1993). (author)

  10. The test of intrinsic uniformity is one of the basic tests to check the status of the detectors of gamma cameras, and as such is contained in RD 1 841/1997 Quality Control in Nuclear Medicine; Protocolo NEMA para el calculo de la uniformidad intrinsica en gamma-camaras: aplicacion y comparacion con el software del fabricante

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Soto, X. L.; Gonzalez Ruiz, C.; Lopez-Boto, M. A.; Polo Cezon, R.

    2015-07-01

    Spanish Protocol Quality Control Instrumentation in Nuclear Medicine provides guidelines for conducting this test, similar to those established in the NEMA protocol NEMA Protocol for the calculation of the uniformity intrinsic in GAMMA cameras: application and comparison with the SQFTWARE of the manufacturer. it is advisable to conduct a study to ensure that the results for the test of intrinsic uniformity of the software provided by the equipment manufacturer are equivalent to those obtained by applying the protocol recommended by the SEFM before using this software for performing quality control. (Author)

  11. Analysis of dosimetry of a Gamma Knife Perfexion using polystyrene and solid water phantoms for small volume ionization chambers; Analise da dosimetria de um Gamma Knife Perfexion utilizando phantoms de poliestireno e de agua solida para camaras de ionizacao de volume pequeno

    Energy Technology Data Exchange (ETDEWEB)

    Costa, N.A.; Potiens, M.P.A., E-mail: nathaliaac@ymail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Saraiva, C.W.C. [Hospital do Coracao (HCor), Sao Paulo, SP (Brazil); Benmakhlouf, H. [Stockholm University, Karolinska Hospital (Sweden)

    2016-07-01

    The Gamma Knife Perfexion (GKP) is a radiosurgery equipment that has been developed by Elekta. Its dose-rate calibration is performed using phantoms developed by Elekta and a small volume ionization chamber. The purpose of this study was to evaluate the collected charge values obtained in its dosimetry using two different phantoms, polystyrene and solid water and the ion chambers PTW Semiflex, volume 0,125 cm{sup 3}, model 31010 and PTW Pinpoint, volume 0,016 cm{sup 3}, model 31016. (author)

  12. Study of radiosensitivity and antioxidant-oxidant state in workers exposed to ionizing radiation in the hospital environment; Estudio de la radiosensibilidad y estado antioxidante-oxidante en trabajadores expuestos a radiaciones ionizantes en el ámbito hospitalario

    Energy Technology Data Exchange (ETDEWEB)

    Sebastià, N.; Rodrigo, R.; Hervás, D.; Olivares-González, L; Óscar Alonso, O.; Marti, L.; Jambrina, E.; Sarrias, A.; Pérez-Calatayud, J.; García, T.; Gras, P.; Villaescusa, J.I.; Soriano, J.M.; León, Z.; Montoro, A.

    2014-07-01

    Prevention and protection of workers exposed to ionizing radiation is an objective of particular importance from the occupational health and safety point of view. This study establishes a technique for the evaluation of the individual radiosensibility of workers exposed to ionizing radiation in the Hospital environment using the cytogenetic biomarker known as the G2 –Test. In addition, using various oxidative stress biomarkers and antioxidant capacity, we evaluate the antioxidant-oxidant state of these workers. Both biomarkers could be established as additional tools in the medical control of workers exposed to ionizing radiation. [Spanish] La prevención y protección de los trabajadores expuestos a radiaciones ionizantes es un objetivo de gran relevancia desde el punto de vista de seguridad ocupacional y salud. Este estudio consiste en la puesta a punto de una técnica de evaluación de la radiosensibilidad individual de los trabajadores expuestos a radiaciones ionizantes en el ámbito hospitalario mediante el biomarcador citogenético conocido como Test G2. Además, utilizando diversos biomarcadores de estrés oxidativo y capacidad anti- oxidante, evaluamos el estado antioxidante-oxidante en estos trabajadores. Ambos biomarcadores podrían establecerse como una herramienta más dentro de la vigilancia médica de los trabajadores expuestos a radiación ionizante.

  13. Electrophoretic characterization of D. melanogaster strains deficient in endogenous anti-oxidants in combination with gamma radiation; Caracterizacion electroforetica de cepas de D. melanogaster deficientes en antioxidantes endogenos en combinacion con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Gomar A, S.

    2012-07-01

    The free radicals derived of the oxygen and other reactive species are generated by endogenous processes as sub-products of the aerobic metabolism or by exogenous factors as the environmental pollution, the biological half life of these free radicals is of microseconds, but they have the capacity of reacting with any atom or molecule to its around causing oxidant stress and damage to molecules, cellular membranes and tissues. To counteract them, there is endogenous and exogenous anti-oxidants, the first ones are synthesized by the organism for maintaining the cellular homeostasis as the superoxide dismutase and catalase. There are recent evidences that indicate that the sodium cooper chlorophyllin (SCC) presents a dual effect reducing and/or increasing the induced genetic damage by different mutagenic agents. One hypothesis for this effect is that the SCC can act as oxidant per se or through some of their metabolites. Results more recent indicated that a similar of the SCC, the protoporphyrin-Ix, can produce genetic damage. In this work exogenous anti-oxidants were used, as the SCC, protoporphyrin-Ix or the bilirubin in the induction of endogenous anti-oxidants enzymes to evaluate the supposed oxidant activity of the SCC and/or their metabolites. Drosophila melanogaster strains deficient in superoxide dismutase, catalase and withered were used and a rustic strain Canton-S as control. In the three experiments were treated 60 males of 1 day of age, with SCC, protoporphyrin-Ix or bilirubin to one concentration of 69 m M during 12 days. Every 4 days 10 males were isolated to measure them the induction of superoxide dismutase and catalase. The results showed that the SCC, protoporphyrin-Ix and bilirubin considered like anti-oxidants, were able to increase the induction of the superoxide dismutase and catalase enzymes. This result maybe is because they are able to generate reactive species of oxygen, as the anion superoxide and the hydrogen peroxide. Among the three proven anti-oxidants the bilirubin induced a major quantity of both enzymes, followed by the protoporphyrin-Ix without metallic ion, and the SCC in minor proportion. Therefore the conclusion is that this action of the SCC can provide it the anti-mutagenic action broadly reported. (Author)

  14. Elimination of vibrio cholerae El Tor, in scallops (Argopecten purpuratus) by gamma radiation and product organoleptic evaluation; Eliminacion de vibrio cholerae, El Tor, en conchas de abanico (Argopecten purpuratus) con el uso de radiacion gamma y evaluacion sensorial del producto

    Energy Technology Data Exchange (ETDEWEB)

    Torres, Z [Instituto Peruano de Energia Nuclear, Lima (Peru); Bernuy, B [Universidad Nacional Agraria la Molina, Lima (Peru); Vivanco, M [Universidad Nacional Federico Villarreal, Lima (Peru); Kahn, G [Universidad Nacional Agraria de la Selva, Pucallpa (Peru)

    1999-03-01

    V. cholerae D{sub 10} value in scallops (Argopecten purpuratus) was determined in vivo. D{sub 10} was found to be 0,143 kGy, requiring therefore the application of 8D in scallops, equivalent to a 1,14 kGy dose, the optimal dose for life span extension of samples kept under refrigeration conditions (0-1{sup o}), and examined periodically under different analytic method criteria. Life span for the appearance characteristic reaches the acceptability limit of 3, after 11 days for control samples, and 16 and 13 days for samples radiated at 1 and 2 kGy. Smell of control samples was accepted only until the 13{sup th} day while samples radiated at 1 and 2 kGy went beyond this level, reaching 19 and 17 days respectively. In the same way, life span for the flavor characteristic was extended to 19 and 20 days for samples radiated at 1 and 2 kGy, respectively, while control samples only reached 15 days. Control sample texture remained within acceptable limits until the 18{sup th} day, whereas samples radiated at 1 and 2 kGy reached 21 and 17 days, respectively. Use of ph and nitrogen volatile bases were also evaluated as quality indicators. (authors) 14 refs., 3 figs., 3 tabs., 1 ill.

  15. Application of gamma radiation to the nodes detection in Pinus Radiata (D.Don) wood pieces; Aplicacion de la radiacion gamma en la deteccion de nudos en piezas de madera de Pino Radiata (D.Don)

    Energy Technology Data Exchange (ETDEWEB)

    Morales, J R; Dinator, Maria I [Chile Univ., Santiago (Chile). Dept. de Fisica; Karsulovic C, Jose T; Leon G, Adolfo [Chile Univ., Santiago (Chile). Dept. de Tecnologia de la Madera

    1997-12-31

    Attenuation of 59.5 KeV photons provided by an Am-241 source, has been used to detect knots in lumber pieces from Pinus Radiata (D.Don). It is shown that the linear attenuation coefficient is a sensitive parameter to detect singularities in the structure of this material. The scanning of the piece provides profiles which define the position and extension of the singularity. (author). 7 refs.

  16. Effect of gamma irradiated parenchyma on the growth of irradiated potato tuber buds; Efecto del parenquina irradiado sobre el desarrollo de las yemas de tuberculos de patata tratados por radiacion GAMMA

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Gonzalez, J; Garcia Collantes, M A

    1976-07-01

    The development of buds greffed on irradiated potato parenchyma was studied. The irradiated parenchyma does not influence the sprouting capacity of buds, but it affects the way they develop. (Author) 9 refs.

  17. Analysis of the dose-response relationship observed in Sprekelia, Petunia and Impatiens treated with gamma radiation; Analisis de la relacion dosis-respuesta observada en Sprekelia, Petunia e Impatiens tratadas con radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez J, J [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2007-07-01

    The present investigation was carried out in order to verifying if it is possible to establish one or a dose range that directly not at random produces a specific effect independently of the species that is treated. The results show that this can be possible if the ranges settle down based on the specific stocking lethal dose for each specie. (Author)

  18. Influence of gamma radiation on the growth and metabolism in vitro culture of potato parenchyma; Influencia de la radiacion gamma sobre el desarrollo y metabolismo del parenquina amilifero de patata cultado in vitro

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Gonzalez, J; Monzon Matanzo, M P

    1977-07-01

    The present work studies the growth in vitro of the parenchyma tissues coming from control and irradiated potato tubers with doses of 3, 6, 9 and 12 Krad. At the end of a four months cultivation period the cellular proliferation, respiratory activity, content in ascorbic acid, conductivity and ph was studied. Some differences between control and irradiated tissues were observed. (Author) 22 refs.

  19. Radiosensitivity study in the germination and growth of the pea Pisum sativum L, with seeds exposed to gamma radiation; Estudio de radiosensibilidad en la germinacion y crecimiento de la arveja Pisum sativum L, con semillas expuestas a radiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Ilguan, J.; Carrasco, J.; Marquez, V., E-mail: ilguanjanneth@gmail.com [Escuela Superior Politecnica de Chimborazo, Facultad de Ciencias, Panamericana Sur Km 1 1/2, ECO60155 Riobamba (Ecuador)

    2016-10-15

    Seeds of Pisum sativum L. were irradiated in a {sup 60}Co irradiator belonging to the Subsecretaria de Control y Aplicaciones Nucleares del Ecuador (SCAN), the dose rate at the irradiation time was 4.86 Gy/min. The seeds were grouped in packs of 100 units and exposed at doses of 20, 40, 60, 80, 100, 120, 140, 160, 180 and 200 Gy. The number of effective germinations, the days for germination, the main stem thickness, the number of branches and the size of the plant were evaluated. To validate the experimentation, the data were analyzed statistically by tests of homogeneity of variances, way ANOVA and Scheffe analysis to each variable. The number of effective germinations was given to 100% for 20 and 40 Gy then decreases to a higher dose reaching 20% to 200 Gy, being the average of the proof near to 90%. Increased germination stimulation at treatment at 20 Gy with an average of 5.0 days was evidenced. Treatment at doses of 20, 40 and 60 Gy generate a plant size greater than the proof whose mean is 68.30 cm. The mean number of branches of the proof is 5.3 with a standard deviation of 0.675, which is greater at doses of 20 and 40 Gy. In the study, is concluded that better results are obtained when irradiating seeds Pisum sativum L, between 20 and 60 Gy. (Author)

  20. Action of the chlorophyllin (CHLN) on the double breaking induced by gamma radiation in germinal cells of Drosophila melanogaster; Accion de la clorofilina (CHLN) sobre los dobles rompimientos inducidos por radiacion gamma en celulas germinales de Drosophila melanogaster

    Energy Technology Data Exchange (ETDEWEB)

    Moreno M, A

    2005-07-01

    The chlorophyllin (CHLN) is a derived of the chlorophyll in the one which the atom of Mg is replaced by Cu. It has been broadly used as preservative in those foods, and in the treatment of geriatric patients. The results using different test systems have demonstrated that the CHLN reduces the DNA damage caused by different physical agents or chemical of direct action or insinuation. Another of the properties of the CHLN is it anti carcinogenic action, because it has been that inhibits the carcinogen activity of B1 (AFB1) aflatoxin and it diminishes the incidence of tumors caused for 2-amine-3-methylimidazo [4- 5f] quinoline (IQ) and it inhibits the development of colon cancer during the post-initiation phase. Recently the reports of the activity promoter of the CHLN have been increased on the genetic damage. This effect observed in Salmonella and later on in Drosophila melanogaster using, physical and chemical agents. Presently study determines the action of the CHLN before the genetic effect induced in germinal cells of Drosophila melanogaster by means of the test of the lost one of the X chromosome in ring using two protocols; the first one consisted on pretreatment with CHLN to the male ones and later on to irradiate them and in the second protocol the pretreatment with CHLN administers to the females, in both protocols its were used a litter systems. (Author)

  1. Gamma radiation applied to extend the shelf-life of lamb meat vacuum packed and stored under refrigeration; Radiacao gama aplicada para estender a vida util da carne de cordeiro embalada a vacuo e armazenada sob refrigeracao

    Energy Technology Data Exchange (ETDEWEB)

    Fregonesi, Raul Pereira

    2013-07-01

    The State of Sao Paulo has experienced in recent years a significant increase in production, supply and consumption of lamb meat. With the current trend of demand for products of greater convenience, with speed and ease preparation, there is the need to invest in the market supply of refrigerated lamb cuts. Accordingly, irradiation with ionizing energy could be a viable alternative for the marketing of refrigerated cuts of lamb meat. The aim of this work was to study the application of different doses of gamma radiation in order to extend the stability of lamb meat vacuum packed and stored under refrigeration. For this, first a preliminary experiment was conducted aiming to determine parameters such as irradiation dose and storage time. The lamb loins (Longissimus dorsi) were vacuum packed, irradiated with doses of 1,0, 3,0 and 5,0 kGy and stored under refrigeration in cooling chamber at 1 °C. According to the results, a dose of 3,0 kGy may be indicated as the maximum dose of irradiation. After establishing these parameters, the final experiment began, and for that, the lamb loin samples were vacuum packaged and irradiated with doses zero (control), 1,5 kGy and 3,0 kGy and stored under refrigeration at 1 °C. In predetermined periods (zero, 14, 28, 42 and 56 days) microbiological and physical chemical analysis were carried out. Also, a sensory acceptance test was conducted, with 63 consumers, which evaluated aroma, texture, juiciness, flavor and overall quality attributes. All data were statistically evaluated using contrasts between means, with a significance level of 5%. The results obtained for microbiological testing of all samples were absence of Salmonella sp. and sporadic counts of coliforms at 45 °C and Staphylococcus aureus (<10 (est) CFU/g). For other microbiological analysis there were significant effects (p <0,05) of treatment, and time. However, for the physicochemical characteristics, there were only differences (p <0,05) of time from zero to 28

  2. Gamma Splines and Wavelets

    Directory of Open Access Journals (Sweden)

    Hannu Olkkonen

    2013-01-01

    Full Text Available In this work we introduce a new family of splines termed as gamma splines for continuous signal approximation and multiresolution analysis. The gamma splines are born by -times convolution of the exponential by itself. We study the properties of the discrete gamma splines in signal interpolation and approximation. We prove that the gamma splines obey the two-scale equation based on the polyphase decomposition. to introduce the shift invariant gamma spline wavelet transform for tree structured subscale analysis of asymmetric signal waveforms and for systems with asymmetric impulse response. Especially we consider the applications in biomedical signal analysis (EEG, ECG, and EMG. Finally, we discuss the suitability of the gamma spline signal processing in embedded VLSI environment.

  3. Dosimetric evaluation of spectrophotometric response of alanine gel solution for gamma, photons, electrons and thermal neutrons radiations; Avaliacao dosimetrica da resposta espectrofotometrica da solucao gel de alanina para radiacao gama, de fotons, de eletrons e de neutrons termicos

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Cleber Feijo

    2009-07-01

    Alanine Gel Dosimeter is a new gel material developed at IPEN that presents significant improvement on Alanine system developed by Costa. The DL-Alanine (C{sub 3}H{sub 7}NO{sub 2}) is an amino acid tissue equivalent that improves the production of ferric ions in the solution. This work aims to analyse the main dosimetric characteristics this new gel material for future application to measure dose distribution. The performance of Alanine gel solution was evaluated to gamma, photons, electrons and thermal neutrons radiations using the spectrophotometry technique. According to the obtained results for the different studied radiation types, the reproducibility intra-batches and inter-batches is better than 4% and 5%, respectively. The dose response presents a linear behavior in the studied dose range. The response dependence as a function of dose rate and incident energy is better 2% and 3%, respectively. The lower detectable dose is 0.1 Gy. The obtained results indicate that the Alanine gel dosimeter presents good performance and can be useful as an alternative dosimeter in the radiotherapy area, using MRI technique for tridimensional dose distribution evaluation. (author)

  4. Quantification of micronuclei in blood lymphocytes of patients exposed to gamma radiation for dose absorbed assessment; Quantificacao de micronucleos em linfocitos de pacientes expostas a radiacao gama para a avaliacao da dose absorvida

    Energy Technology Data Exchange (ETDEWEB)

    Barbosa, Isvania Maria Serafim da Silva

    2003-02-15

    Dose assessment in an important step to evaluate biological effects as a result of individual exposure to ionizing radiation. The use of cytogenetic dosimetry based on the quantification of micronuclei in lymphocytes is very important to complement physical dosimetry, since the measurement of absorbed dose cannot be always performed. In this research, the quantification of micronuclei was carried out in order to evaluate absorbed dose as a result of radiotherapy with {sup 60}Co, using peripheral blood samples from 5 patients with cervical uterine cancer. For this purpose, an aliquot of whole blood from the individual patients was added in culture medium RPMI 1640 supplemented with fetal calf serum and phytohaemagglutinin. The culture was incubated for 44 hours. Henceforth, cytochalasin B was added to block the dividing lymphocytes in cytokinesis. The culture was returned to the incubator for further of 28 hours. Thus, cells were harvested, processed and analyzed. Values obtained considering micronuclei frequency after pelvis irradiation with absorption of 0,08 Gy and 1,8 Gy were, respectively, 0,0021 and 0,052. These results are in agreement with some recent researches that provided some standard values related to micronuclei frequency induced by gamma radiation exposure in different exposed areas for the human body. The results presented in this report emphasizes biological dosimetry as an important tool for dose assessment of either total or partial-body exposure to ionizing radiation, mainly in retrospective dose investigation. (author)

  5. Project, construction and characterization of ionization chambers for use as standard systems in X and gamma radiation beams; Projeto, construcao e caracterizacao de camaras de ionizacao para utilizacao como sistemas padroes em feixes de radiacao X e gama

    Energy Technology Data Exchange (ETDEWEB)

    Perini, Ana Paula

    2013-07-01

    Ionization chambers present some advantages in relation to other dosimeters: easiness of handling, low energy dependence and high precision. The advantages associated to ionization chambers and the large number of diagnostic radiology exams and therapeutic treatments motivated the development of this PhD program. In this project ionization chambers were developed and characterized to be applied in diagnostic radiology and therapy beam dosimetry, with high precision and performance, in compliance with international recommendations. They were assembled in a simple way, utilizing low-cost national materials, so they can be reproduced and applied at calibration laboratories. The project of these ionization chambers presents some differences in relation to commercial ionization chambers, as the materials utilized and geometrical arrangements. Besides the development of the ionization chambers to be utilized in standard X-ray beam dosimetry as work standard systems, two graphite parallel-plate ionization chambers were developed and characterized to be applied as reference standard systems for determining the air kerma rates of gamma radiation sources. Comparing the air kerma rates determined with the reference standard of the Calibration Laboratory of IPEN, a Farmer ionization chamber, with the values of the air kerma rates obtained with the graphite ionization chambers, the maximum differences obtained were only 1.7% and 1.2% for the G1 and G2 graphite ionization chambers, respectively. Moreover, these ionization chambers presented correction factors close to 1.000, which is ideal for an ionization chamber be characterized as a reference standard system. (author)

  6. The use of Gamma radiation of Cobalt-60 to control avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit of Persea americana (Miller) (Lauraceae).; Uso da radiacao gama do Cobalto-60, para controlar a broca-do-abacate Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) e seus efeitos na qualidade do fruto de Persea americana (Miller) (Lauraceae)

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Lilian Karla Figueira da

    2004-07-01

    This work aimed to evaluate the influence of Gamma radiation of Cobalt-60, in the avocado moth Stenoma catenifer Walsingham, 1912 (Lepidoptera: Elachistidae) and its effects on the quality of the fruit Persea americana (Miller) (Lauraceae). For this research, insects were irradiated in ali phases of their life cycle with doses varying from O to 600 Gy and they were maintained at the temperature of 25 +- 2 deg C, humidity of 70 +- 10% and photo phase of 14 h. The species was raised on natural diet, avocado seeds. The cultivar fruits Geada were irradiated with doses that varied from 0 to 150 Gy, maintained for 15 days at room temperature (20 a 35 deg C and humidity of 70 - 80 %) and 30 days at a temperature of 10 deg C, humidity of 40 - 60 %. The chemical-physics and sensorial analyses were carried out. According to the obtained results, it was verified that the lethal dose of gamma radiation to S. catenifer eggs, was of 75 Gy; for caterpillars and pupas was of 300 Gy. The sterile-dose for upcoming adults from irradiated S. catenifer eggs was of 25 Gy; for upcoming adults from irradiated caterpillars, it was of 100 Gy; for adults coming from irradiated pupas was of 150 Gy and for irradiated adults was of 200 Gy. The irradiation in the avocado fruit, maintained at room temperature for 7 days of storage, caused change in the coloration of the fruit (dark spots and yellowish coloration) and more firmness. The sensorial characteristics were kept and the irradiated fruit was the chosen one as favorite for tasting. The irradiated fruits that were kept at 10 deg C, obtained an increase in the storage period, without changing their chemical physics characteristics. The coloration of the fruits was kept, more firmness and a subtle acidity taste increase, being effective in the conservation of the fruits and in the maintenance of their sensorial characteristics. The use of the gamma radiation as treatment quarantine of S. catenifer it was efficient, should be treated them with

  7. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Fichtel, C.E.

    1975-01-01

    The first certain detection of celestial high energy gamma rays came from a satellite experiment flown on the third Orbiting Solar Observatory (OSO-111). A Gamma ray spark chamber telescope with substantively greater sensitivity and angular resolution (a few degrees) flown on the second Small Astronomy Satellite (SAS-II) has now provided a better picture of the gamma ray sky, and particularly the galactic plane and pulsars. This paper will summarize the present picture of gamma ray astronomy as it has developed at this conference from measurements made with experiments carried out on balloons, those remaining on the ground, and ones flown on satellites. (orig.) [de

  8. Interpretation of the gamma interferon test for diagnosis of subclinical paratuberculosis in cattle

    DEFF Research Database (Denmark)

    Jungersen, Gregers; Huda, A.; Hansen, J.J.

    2002-01-01

    A group of 252 cattle without clinical signs of paratuberculosis (paraTB) in 10 herds infected with paraTB and a group of 117 cattle in 5 herds without paraTB were selected. Whole-blood samples were stimulated with bovine, avian, and johnin purified protein derivative (PPD) and examined for gamma...... interferon (IFN-gamma) release. For diagnosis of paraTB, satisfactory estimated specificities (95 to 99%) could be obtained by johnin PPD stimulation irrespective of interpretation relative to bovine PPD or no-antigen stimulation alone, but numbers of test positives in the infected herds varied from 64...

  9. Gamma tomography apparatus

    International Nuclear Information System (INIS)

    Span, F.J.

    1988-01-01

    The patent concerns a gamma tomography apparatus for medical diagnosis. The apparatus comprises a gamma scintillation camera head and a suspension system for supporting and positioning the camera head with respect for the patient. Both total body scanning and single photon emission tomography can be carried out with the apparatus. (U.K.)

  10. Gamma-sterilization

    International Nuclear Information System (INIS)

    Lindgren, E.

    1974-01-01

    The author makes a survey of his experience in sterilization and sterility control of medical products. At present three different methods are used, steamsterilization, gassterilizing and gammasterilizing. The investments and costs for gamma radiation is presented and a comparison of the costs for gamma- and gassterilization including sterility control is made. (M.S.)

  11. Gamma-ray sources

    International Nuclear Information System (INIS)

    Hermsen, W.

    1980-01-01

    Results are presented from an analysis of the celestial gamma-ray fine-scale structure based on over half of the data which may ultimately be available from the COS-B satellite. A catalogue consisting of 25 gamma-ray sources measured at energies above 100 MeV is presented. (Auth.)

  12. Gamma ray astronomy

    International Nuclear Information System (INIS)

    Hillier, R.

    1984-01-01

    The book reviews the development of gamma ray astronomy over the past twenty five years. A large section of the book is devoted to the problems of background radiation and the design of detectors. Gamma rays from the sun, the galactic disc, the galaxy, and extra galactic sources; are also discussed. (U.K.)

  13. Effect of the ionizing radiation in polyurethane of medical grade; Efecto de la radiacion ionizante en poliuretano de grado medico

    Energy Technology Data Exchange (ETDEWEB)

    Ceron, P.; Rivera, T.; Calderon, J. A. [IPN, Centro de investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria 694, Col. Irrigacion, 11500 Mexico D. F. (Mexico); Paredes, L., E-mail: victceronr@hotmail.com [ININ, Carretera Mexico-Toluca, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2011-10-15

    The polyurethane is a material broadly used in implant medical devices, such as the connection blocks of the pacemakers and the insulator of the electrodes. Some patients that are users of these devices possibly have the necessity to receive external radiotherapy. For that reason is necessary to know the effects induced by the ionizing radiation in this polymer. In this study samples of Pellethane 2363 80a (thermoplastic polyurethane of medical grade) were irradiated. It was used the same energy and absorbed dose of a treatment of external radiotherapy in pelvis, by means of a linear accelerator of X-rays of 6 MeV and absorbed dose of 60 Gy to isocenter. The irradiation corresponding to the gamma sterilization of the material was reproduced (1, 5, 7.5, 10 and 25 kGy for the Co 60) the effects induced by the radiotherapy and for the sterilization in the material were studied by means of an analysis of the chemical connection, the molecular structure and identification of the functional groups of the polymer, by means of the infrared spectroscopy by Fourier transform in the infrared half region. (Author)

  14. Application gamma radiation of cobalt-60 in disinfestation of some types of rations for feeding small animals; Emprego da radiacao gama do cobalto-60 na desinfestacao de alguns tipos de racoes para alimentacao de animais de pequeno porte

    Energy Technology Data Exchange (ETDEWEB)

    Arthur, Paula Bergamin

    2012-07-01

    The pests as beetles, mites, moths and mushrooms among other, usually infest products stored as: grains, crumbs, flours, coffee, tobacco, dried fruits, animal rations, spices, dehydrated plants, causing the visual depreciation and promoting to deterioration of the products. The present research had as objective the use of the gamma radiation in the disinfestation of some types of rations used for feeding animals of small size. In the first experiment packing of free samples were used measuring 10 cm x 20 cm with capacity of 70 grams of substrate (ration) with 4 types of existent marks in the trade: (1), (2), e (3), and (4). Each treatment consisted of 10 repetitions, that were irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy, to do the disinfestation of the samples. After the irradiation (disinfestation) of the all irradiated packing and more the control was conditioned in plastic boxes of 80 cm x 50 cm with cover, where the insects were liberated Lasioderma serricorne, Plodia interpuctella, Sitophilus zeamais and Sitophilus oryzae, in a total of 400 for each box and maintained at room acclimatized with 27 {+-} 2 Deg C and relative humidity of 70 {+-} 5%. In the second experiment packing were used made with the materials of packing of the first experiment. Each packing was made of 10 cm x 15 cm, with capacity of 30 grams of substrate (ration). In each repetition was inoculated 10 insects of each species, in a total of 400 insects for experiment per box. The packing with substrate and insect, were stamped in commercial machine and irradiated with doses of: 0 (control) 0,5; 1,0 and 2,0 kGy. The irradiated packing and the control were maintained at room acclimatized same the mentioned in the first experiment. The counting of the number of insects and holes in the packing were made after 60 days. Concluded that only the packing of the ration type number 4 was susceptive to attack of all species of insects. The dose of 0,5 kGy was sufficient to induce the

  15. GammaWorkshops Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H. (ed.) (Swedish Defence Research Agency (Sweden)); Straalberg, E. (Institute for Energy Technology, Kjeller (Norway)); Klemola, S. (Radiation and Nuclear Safety Authority, STUK (Finland)); Nielsen, Sven P. (Technical Univ. of Denmark. Risoe National Lab. for Sustainable Energy, Roskilde (Denmark)); Palsson, S.E. (Icelandic Radiation Safety Authority (Iceland))

    2012-01-15

    Due to a sparse interaction during the last years between practioners in gamma ray spectrometry in the Nordic countries, a NKS activity was started in 2009. This GammaSem was focused on seminars relevant to gamma spectrometry. A follow up seminar was held in 2010. As an outcome of these activities it was suggested that the 2011 meeting should be focused on practical issues, e.g. different corrections needed in gamma spectrometric measurements. This three day's meeting, GammaWorkshops, was held in September at Risoe-DTU. Experts on different topics relevant for gamma spectrometric measurements were invited to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical sessions. The practical sessions included demonstrations of tools for e.g. corrections and calculations of the above meantioned topics. (Author)

  16. A Depth-Focusing Collimator for the Investigation of the Brain Cortex; Collimateur a Focalisation Profonde pour l'Exploration de la Substance Corticale du Cerveau; Kollimator s glubinnoj fokusirovkoj dlya''issledovaniya kory golovnogo mozga; Colimador de Enfoque Profundo para Estudios de la Corteza Cerebral

    Energy Technology Data Exchange (ETDEWEB)

    Glasswestern, H. I. [Regional Hospital Board, Glasgow (United Kingdom)

    1964-10-15

    mesurer, a l'aide de {sup 133}Xe, des flux sanguins localises dans la substance corticale du cerveau. Toutefois, l'appareil permet aussi de detecter, avec des produits chimiques marques par {sup 125}l, des tumeurs et des hemorragies de la substance corticale. (author) [Spanish] El autor describe un detector que consiste en un cristal de yoduro de sodio, de 5 pulg de diametro y i de pulg de espesor, y un colimador de enfoque profundo. En principio, el colimador fue diseflado para el estudio de la circulacion sanguinea en la corteza cerebral mediante el {sup 133}Xe, pero puede utilizarse tambien con otros emisores de rayos gamma blandos, por ejemplo, el {sup 125}I. El colimador, de plomo, tiene Inverted-Question-Mark de pulg de espesor y es de tipo multicanal. El foco esta situado a 1,75 cm de la cara anterior. La respuesta en aire a una fuente puntiforme que se mueva a lo largo del eje central del colimador decrece hasta el {sup 125}I del valor maximo a {+-} 0,75 cm del foco. La respuesta en tejidos para campos alejados es considerablemente mejor que en aire debido a que los tejidos atenuan mucho la radiacion gamma blanda. El autor describe la respuesta del colimador a una fuente puntiforme situada en el aire y dentro de un craneo. El colimador se ha empleado para medir, con ayuda de {sup 133}Xe, la circulacion sanguinea en la corteza cerebral; pero mediante productos quimicos marcados con {sup 125}I, permite tambien detectar hemorragias y tumores corticales. (author) [Russian] Opisyvaetsja detektor , sostojashhij iz kristalla iodistogo natrija dimetrom 12,5 sm i tolshhinoj 6,2 mm kollimatora s glubinnoj fokusirovkoj. Kollimator pervonachal'no prednaznachalsja dlja issledovanija krovoobrashhenija v kore golovnogo m o zga s pomoshh'ju ks en on a -133 , no mozhno takzhe ispol'zovat' i drugie mjagkie gamma-izluchajushhie i zo topy, naprimer j o d -125. Kollimator so svincovym korpusom tolshhinoj 6m m javljaetsja mnogokanal'nym. Fokus nahoditsja na rasstojanii 1,75 sm ot

  17. The gamma function

    CERN Document Server

    Artin, Emil

    2015-01-01

    This brief monograph on the gamma function was designed by the author to fill what he perceived as a gap in the literature of mathematics, which often treated the gamma function in a manner he described as both sketchy and overly complicated. Author Emil Artin, one of the twentieth century's leading mathematicians, wrote in his Preface to this book, ""I feel that this monograph will help to show that the gamma function can be thought of as one of the elementary functions, and that all of its basic properties can be established using elementary methods of the calculus."" Generations of teachers

  18. Development of an analytical model for the determination of {sup 60}Co in aqueous samples by atomic absorption and gamma spectrometry techniques; Elaboracion de un modelo analitico para la determinacion de {sup 60}Co en muestras acuosas mediante tecnicas de absorcion atomica y espectrometria gamma

    Energy Technology Data Exchange (ETDEWEB)

    Solis A, N. A.

    2015-07-01

    The applications of the nuclear energy in industry and medicine generate radioactive wastes that must be isolated and confined in order to limit its spread in the biosphere. These types of wastes are generated in hospitals, industry, research centers and nuclear power plants (during de fuel cycle). The radioactive elements (radionuclides) cannot be destroyed by any known method, either chemical or mechanical. Its final destruction is produced by radioactive decay, which makes them stable isotopes, or nuclear transmutation being bombarded with atomic particles. Consequently, the radioactive waste management is to control the radioactive discharges and reduce to tolerable limits, eliminating of effluents and wastes the radionuclides of interest, concentrating them so they can be stored or evacuated so that later not appear in dangerous concentration in the biosphere. In Mexico, the main generators of radioactive wastes are the nuclear power plant of Laguna Verde in Veracruz, Hospitals of the public and private sector, in addition Instituto Nacional de Investigaciones Nucleares (ININ) some institutes and facilities of the UNAM and Instituto Politecnico Nacional (IPN) and industries among others. The aqueous radioactive wastes, particularly those from the nuclear power plants contain traces of cobalt-60. Currently there is no model or analytical technique for the separation of this radionuclide, so it became necessary to develop an analytical model for separation and facilitate their disposal. In this paper was shown that atomic absorption and gamma spectrometry techniques can separate the active concentration of the inactive, which is important because the total concentration can be associated through direct relationships with the wear of metal parts of the nuclear reactor, since the metal alloys of the same reactor containing a fraction of cobalt. Also this analytical and mathematical model that can be reproducible and applicable to full sets of samples and that this

  19. Investigation on possible risks to human health by exposure to the radiation of electromagnetic waves produced by the radio communications; Investigacion sobre posibles riesgos a la salud humana por exposicion a la radiacion de ondas electromagneticas producidas por las radiocomunicaciones

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Hernandez, Carlos Felipe; Ibarguengoytia Gonzalez, Pablo Hector; Flores Garcia, Andres; Franco Campos, Laura Elena [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2011-06-13

    This verification procedure is based on a research work on the possible risks to human health by exposure to the radiation of electromagnetic waves produced by the radio communications, cases of study: cellular telephony, radio digital troncalized and wireless telephony IP of Voice on IP (wireless local area network). The revision of all the international standards and the applicable national standardization was included, as well as the verification of fulfillment. [Spanish] Este procedimiento de verificacion esta basado en un trabajo de investigacion sobre posibles riesgos a la salud humana por exposicion a la radiacion de ondas electromagneticas producidas por la radiocomunicaciones, casos de estudio: telefonia celular, radio troncalizado digital y telefonia IP inalambrica de Voz sobre IP (red de area local inalambrica). Se incluyo la revision de todos los estandares internacionales y de la normatividad nacional aplicable, asi como la verificacion de cumplimiento.

  20. Optimization of Gamma-Ray Counting and Spectrometry in Biomedical Tracer Studies; Optimisation du Comptage et de la Spectrometrie des Rayons Gamma dans des Etudes Biomedicales Faites a l'Aide de Traceurs; Optimizatsiya gamma-scheta i spektrometrii gamma-luchej v biomeditsinskikh issledovaniyakh s pomoshch'yu indikatorov; Optimizacion del Recuento y de la Espectrometry Gamma en los Estudios Biomedicos con Indicadores

    Energy Technology Data Exchange (ETDEWEB)

    Guinn, V. P. [General Dynamics Corporation, San Diego, CA (United States)

    1965-10-15

    de recuento se ha calculado la actividad especifica minima detectable de la muestra, asi como los niveles requeridos para las precisiones estadfsticas (expresadas como desviaciones tipo) de {+-} 20%, {+-} 10%, {+-} 5% y {+-}2% En varios casos se han comparado los limites calculados con valores experimentales. Se ha prestado especial atencion a las mejores condiciones para reducir al mfnimo las contribuciones de los rayos X generados en el plomo, de los rayos gamma retrodispersos, de los maximos de escape, de las particulas beta de las muestras y de las radiaciones de frenado. (author) [Russian] V biomedicinskih issledovanijah s pomoshh'ju indikatorov, osobenno ljudej i, tem bolee, detej i beremennyh zhenshhin, vazhno rabotat' pri naimenee nizkom urovne vvodimyh radioizotopov, naskol'ko jeto sovmestimo s trebuemoj tochnost'ju i pravil'nost'ju posledujushhih izmerenij radioaktivnosti. Analo- gichnym obrazom, v sluchae vvedenija v organizm stabil'nyh jelementov (v vide opredelennyh soedinenij) ili obogashhennyh stabil'nyh izotopov (opjat'-taki v vide soedinenij) dlja dal'- nejshego radioaktivacionnogo analiza poluchennyh prob, s tochki zrenija toksikologii vazhno sokrashhat' do minimuma kolichestvo vvodimogo jelementa. V laboratorijah byla tshhatel'no izuchena problema optimizacii otschityvanija odnogo, dvuh n treh gamma-izluchajushhih radioizotopov pri pomoshhi scintilljacionnyh schetchikov s kristallom NaJ(Tl), odnokanal'noj i mnogokanal'noj spektrometrii, prichem osoboe vni- manie udeljalos' issledovanijam pri pomoshhi mechenija odnim, dvumja ili tremja indikatorami, naibolee chasto ispol'zuemymi v bnomedicinskih issledovanijah, a imenno: hrom-51, zoloto-198, selen-75, rtut'-197, med'-64, mysh'jak-76, brom-82, zhelezo-59, kobal't-60, kal'cij-42 i natrij-24. Odinakovye soobrazhenija otnosjatsja k opredeleniju pri pomoshhi shiroko ispol'zuemogo aktivacionnogo analiza teplovymi nejtronami sootvetstvujushhih jelementov ili obogashhennyh stabil'nyh izotopov, tak chto

  1. Basics of Gamma Ray Detection

    Energy Technology Data Exchange (ETDEWEB)

    Stinnett, Jacob [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Venkataraman, Ram [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-09-13

    The objective of this training is to explain the origin of x-rays and gamma rays, gamma ray interactions with matter, detectors and electronics used in gamma ray-spectrometry, and features of a gamma-ray spectrum for nuclear material that is safeguarded.

  2. Progresos recientes en Astronomía de Rayos Gamma

    Science.gov (United States)

    Romero, G. E.

    Tras la exitosa misión del Compton Gamma-Ray Observatory durante los años 1990, la astronomía de rayos gamma ha entrado en una etapa de madurez, convirtiéndose en una de las principales herramientas para el estudio de procesos relativistas en el universo. En este reporte, presentaré una revisión de los principales tópicos abordados a través de estudios con rayos gamma en los últimos años, con particular énfasis en los intentos más recientes por establecer la naturaleza de las fuentes de rayos gamma no identificadas, detectadas por el instrumento EGRET.

  3. Analysis of passive systems as a tool for energy saving in buildings: solar control; Analisis de sistemas pasivos como herramienta para el ahorro de energia en edificaciones: Control solar

    Energy Technology Data Exchange (ETDEWEB)

    Saravia, Maricela; Morillon Galvez, David [Instituto de Ingenieria, UNAM, Mexico, D. F. (Mexico)

    1999-07-01

    A bioclimatic study of El Salvador is presented, with the purpose of using window eaves as elements of passive solar control and to determine the optimal angles of orientation, in order to diminish the thermal gains by direct solar radiation and to manage to get close to the comfort conditions. The former with the intention of integrating measures that help to obtain energy efficiency and comfortable buildings, for the conditions of warm humid climate, characteristic of a Central American country like El Salvador. Besides offering a document of consultation among the professionals dedicated to the design and as base of bioclimatic considerations that must have the construction regulations. As a conclusion the optimal angles of eaves for each orientation are presented and a quantitative estimation of the savings that would imply not to consume electrical energy in cooling systems using these elements as a protection to the direct solar radiation. [Spanish] Se presenta un estudio del bioclima de El Salvador, con el fin de utilizar aleros de ventana como elementos de control solar pasivo y determinar los angulos optimos por orientacion, para disminuir las ganancias termicas por radiacion solar directa y lograr acercar a las condiciones de confort. Lo anterior con el objeto de integrar medidas que coadyuven a lograr edificios energeticamente eficientes y confortables, para las condiciones de clima calido humedo, caracteristico de un pais centroamericano como El Salvador. Ademas de brindar un documento de consulta entre los profesionales dedicados al dise y como base de consideraciones bioclimaticas que debe tener el reglamento de construcciones. Como conclusion se presentan los angulos optimos de alero por cada orientacion y una estimacion cuantitativa del ahorro que implicaria el no consumir energia electrica en sistemas de enfriamiento utilizando estos elementos como una proteccion a la radiacion solar directa.

  4. GammaWorkshops Proceedings

    DEFF Research Database (Denmark)

    Strålberg, Elisabeth; Klemola, Seppo; Nielsen, Sven Poul

    to the GammaWorkshops. The topics included efficiency transfer, true coincidence summing corrections, self-attenuation corrections, measurement of natural radionuclides (natural decay series), combined measurement uncertainty calculations, and detection limits. These topics covered both lectures and practical...

  5. FTR europia gamma heating

    International Nuclear Information System (INIS)

    Ward, J.T. Jr.

    1975-01-01

    Calculated and experimental gamma heating rates of europia in the Engineering Mockup Critical Assembly (EMC) were correlated. A calculated to experimental (C/E) ratio of 1.086 was established in validating the theoretical approach and computational technique applied in the calculations. Gamma heat deposition rates in the FTR with Eu 2 O 3 control absorbers were determined from three-dimensional calculations. Maximum gamma heating was found to occur near the tip of a half-inserted row 5 control rod assembly--12.8 watts/gm of europia. Gamma heating profiles were established for a single half-inserted europia absorber assembly. Local heat peaking was found not to alter significantly heating rates computed in the FTR core model, where larger mesh interval sizes precluded examination of spatially-limited heating gradients. These computations provide the basis for thermal-hydraulic analyses to ascertain temperature profiles in the FTR under europia control

  6. Beta and Gamma Gradients

    DEFF Research Database (Denmark)

    Løvborg, Leif; Gaffney, C. F.; Clark, P. A.

    1985-01-01

    Experimental and/or theoretical estimates are presented concerning, (i) attenuation within the sample of beta and gamma radiation from the soil, (ii) the gamma dose within the sample due to its own radioactivity, and (iii) the soil gamma dose in the proximity of boundaries between regions...... of differing radioactivity. It is confirmed that removal of the outer 2 mm of sample is adequate to remove influence from soil beta dose and estimates are made of the error introduced by non-removal. Other evaluations include variation of the soil gamma dose near the ground surface and it appears...... that the present practice of avoiding samples above a depth of 0.3 m may be over-cautious...

  7. Gamma spectrometry today

    International Nuclear Information System (INIS)

    Hemingway, J.

    1990-01-01

    This paper reviews the important advances in gamma spectroscopy made in recent years. Improvements in detectors and other components and the addition of on-line computer control systems is discussed. (UK)

  8. Dynamic gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Luan Shuang; Swanson, Nathan; Chen Zhe; Ma Lijun

    2009-01-01

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can obtain a family of plans representing a tradeoff between the delivery time and

  9. Dynamic gamma knife radiosurgery

    Energy Technology Data Exchange (ETDEWEB)

    Luan Shuang; Swanson, Nathan; Chen Zhe [Department of Computer Science, University of New Mexico, Albuquerque, NM 87131 (United States); Ma Lijun [Department of Radiation Oncology, University of California San Francisco, San Francisco, CA 94143 (United States)], E-mail: sluan@cs.unm.edu, E-mail: nate@cs.unm.edu, E-mail: zchen@cs.unm.edu, E-mail: lijunma@radonc.ucsf.edu

    2009-03-21

    Gamma knife has been the treatment of choice for various brain tumors and functional disorders. Current gamma knife radiosurgery is planned in a 'ball-packing' approach and delivered in a 'step-and-shoot' manner, i.e. it aims to 'pack' the different sized spherical high-dose volumes (called 'shots') into a tumor volume. We have developed a dynamic scheme for gamma knife radiosurgery based on the concept of 'dose-painting' to take advantage of the new robotic patient positioning system on the latest Gamma Knife C(TM) and Perfexion(TM) units. In our scheme, the spherical high dose volume created by the gamma knife unit will be viewed as a 3D spherical 'paintbrush', and treatment planning reduces to finding the best route of this 'paintbrush' to 'paint' a 3D tumor volume. Under our dose-painting concept, gamma knife radiosurgery becomes dynamic, where the patient moves continuously under the robotic positioning system. We have implemented a fully automatic dynamic gamma knife radiosurgery treatment planning system, where the inverse planning problem is solved as a traveling salesman problem combined with constrained least-square optimizations. We have also carried out experimental studies of dynamic gamma knife radiosurgery and showed the following. (1) Dynamic gamma knife radiosurgery is ideally suited for fully automatic inverse planning, where high quality radiosurgery plans can be obtained in minutes of computation. (2) Dynamic radiosurgery plans are more conformal than step-and-shoot plans and can maintain a steep dose gradient (around 13% per mm) between the target tumor volume and the surrounding critical structures. (3) It is possible to prescribe multiple isodose lines with dynamic gamma knife radiosurgery, so that the treatment can cover the periphery of the target volume while escalating the dose for high tumor burden regions. (4) With dynamic gamma knife radiosurgery, one can

  10. Feasibility of ionizing radiation decontamination of ready to eat fresh vegetable salads for immunosuppressed patients; Factibilidad de la descontaminacion por radiaciones ionizantes de ensaladas listas para consumir para incluirse dentro de la dieta limpia de paciente inmunosuprimidos

    Energy Technology Data Exchange (ETDEWEB)

    Horak, Celina I; Narvaiz, Patricia; Kairiyama, Eulogia; Adeil Pietranera, Maria S [Comision Nacional de Energia Atomica, Ezeiza (Argentina). Dept. de Aplicaciones Tecnologicas y Agropecuarias; Gimenez, Palmira; Gronostajsky, D [Hospital Pinero, Buenos Aires (Argentina). Servicio de Nutricion

    2003-07-01

    In the last years consumer trends have increased for fresh like and minimally processed foods. Also, foods are frequently requested without or reduced chemical preservatives. Minimally processed foods have a limited shelf life and mainly rely on HACCP and refrigeration for preservation. However, over the last years, the detection of food borne illness outbreaks associated with fresh vegetables and fruits has increased. This is possible because these product characteristics, high moisture and their cut surface, provide excellent conditions for microorganisms growth. As the feasibility of applying ionizing radiation to inactivate microorganisms is well known, this project will contribute to define the minimal and maximum doses in order to assure the hygienic quality and shelf life of this fresh pre-cut vegetables and fruits. Immunosuppressed patients have different classes of diets, depending on the immunosuppression grade. The hygienic quality was determined on the basis of levels 2 and 3, for (recovery and ambulatory patients respectively). The products investigated were carrots and tomatoes and the irradiation facility was a Cobalt Source. The microorganisms analysed were TBC, Mould and Yeasts, Total coliforms and faecal coliforms. Sensorial evaluation was carried out on the basis of a hedonic scale. (author)

  11. IMEF gamma scanning system

    Energy Technology Data Exchange (ETDEWEB)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs.

  12. IMEF gamma scanning system

    International Nuclear Information System (INIS)

    Baek, Sang Yeol; Park, Dae Kyu; Ahn, Sang Bok; Ju, Yong Sun; Jeon, Yong Bum.

    1997-06-01

    The gamma scanning system which is installed in IMEF is the equipment obtaining the gamma ray spectrum from irradiated fuels. This equipment could afford the useful data relating spent fuels like as burn-up measurements. We describe the specifications of the equipment and its accessories, and also described its operation procedure so that an operator can use this report as the operation procedure. (author). 1 tab., 11 figs., 11 refs

  13. Radar, geologic, airborne gamma ray and Landsat TM digital data integration for geological mapping of the Estrela granite complex (Para State); Integracao digital de imagens de radar e Landsat-TM com dados geologicos e aerogamaespectrometricos no auxilio ao mapeamento geologico da regiao do complexo granitico Estrela-Para (PA)

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, Edson Ricardo Soares Pereira da

    2002-07-01

    This work is focused on the geotectonic context of the Carajas Mineral Province, Amazon Craton, which represents the most important Brazilian Mineral Province and hosts iron, cooper, gold, manganese and nickel deposits. At the end of Archean age, during the techno-metamorphic evolution, moderated alkaline granitoids were generated, such as, Estrela Granite Complex (EGC). This work has used digital integration products with the purpose of study the granite suite, its host rock, and the surrounded area. The digital integrated data were gamma-ray and geological data with satellite images (SAR-SAREX e TM-Landsat). The geophysics data, originally in 32 bits and grid format, were interpolated and converted to 8 bits images. The geological data (facies map) was digitalized and converted to a raster format. The remote sensing images were geometrically corrected to guarantee an accuracy on the geological mapping. On the data processing phase, SAR images were digital integrated with gamma-ray data, TM-Landsat image and the raster facies map. The IHS transformation was used as the technique to integrate the multi-source data. On the photogeological interpretation, SAR data were extremely important to permit the extraction of the main tectonic lineaments which occur on the following directions: +/- N45W, +/- N70W, +/- NS, +/- N20E, +/- N45E e +/- N75E. This procedure was done both in analogic and automatic form, being the automatic process more useful to complement information in the extracting process. Among the digital products generated, SAR/GAMA products (uranium, thorium and total count) were the ones that give the most important contribution. The interpretation of the SAR/GAMA's products added to the field campaign have allowed to map the limits of units that occur in the region and four facies of the Estrela Granite Complex were detected. The origin of the granite suite might be related to a magmatic differentiation or to distinct intrusion pulses. The use of the

  14. Tl response of KMgF{sub 3}: Lu + PTFE at ultraviolet radiation; Respuesta Tl de KMgF{sub 3}: Lu + PTFE a radiacion ultravioleta

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez, P R [Instituto Nacional de Investigaciones Nucleares, A.P. 18 -1027, 11801 Mexico D.F. (Mexico); Alarcon, N G [Facultad de Quimica, Universidad Autonoma del Estado de Mexico. Paseo Tollocan, Esq. con Jesus Carranza, 50180 Toluca, Estado de Mexico (Mexico); Furetta, C; Azorin, J [Universidad Autonoma Metropolitana- Iztapalapa, San Rafael Atlixco 186, 09340 Mexico. D.F. (Mexico)

    2003-07-01

    Ionizing radiation has different types of interaction with a crystalline solid. However, only few effects are interesting to optimize some thermoluminescent (Tl) properties of certain Tl materials. This paper presents results obtained by irradiating KMgF{sub 3}: Lu + Ptfe Tl dosimeters with ultraviolet (UV) radiation previously exposed to gamma radiation. These results showed that those dosimeters not exposed previously to gamma radiation did not presented any Tl signal. Meanwhile, those previously submitted to gamma irradiation showed that their sensitivity was increased as the gamma dose increased. The glow curve of sensitized KMgF{sub 3}: Lu + Ptfe exposed to UV radiation, presented the dosimetric pea at 212 C. This makes this material to be promissory for measuring UV radiation. (Author)

  15. Solar energy as fuel to move the world; La energia solar como combustible para mover al mundo

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, Arturo; Gamboa, Sergio [Centro de Investigacion en Energia (CIE) de la UNAM, Temixco, Morelos (Mexico)

    2010-07-01

    Among the technologies that can be used to take properly advantage of the Sun, we have the development of various solar devices, ranging from the solar collectors, equipment that convert the solar radiation into heat, until the solar cells that convert sunlight into electricity. The development and implementation of these devices in various countries of the world, has allowed us to evaluate the technical feasibility of the technologies associated with the development and use of Renewable Energies to solve the global energy problems, and, in this way, achieve the long-awaited energy independence to which aspire all the nations of the planet. [Spanish] Entre las tecnologias que se pueden utilizar para aprovechar de forma adecuada al Sol, tenemos el desarrollo de diversos dispositivos solares, los cuales van desde los captadores solares, equipos que convierten la radiacion solar en calor, hasta las celdas solares, que convierten la luz del Sol en electricidad. El desarrollo e implementacion de estos dispositivos en diversos paises del mundo, han permitido evaluar la factibilidad tecnica de las tecnologias asociadas al aprovechamiento y uso de las Energias Renovables para resolver los problemas energeticos globales, y, de esta forma, conseguir la tan ansiada independencia energetica a la que aspiran todas las naciones del planeta.

  16. System for gamma-gamma formation density logging while drilling

    International Nuclear Information System (INIS)

    Paske, W.C.

    1991-01-01

    The patent relates to a system for logging subterranean formations for the determination of formation density by using gamma radiation. Gamma ray source and detection means are disposed within a housing adapted for positioning within a borehole for the emission and detection of gamma rays propagating through earth formations and borehole drilling fluid. The gamma ray detection means comprises first and second gamma radiation sensors geometrically disposed within the housing, the same longitudinal distance from the gamma ray source and diametrically opposed in a common plane. A formation matrix density output signal is produced in proportion to the output signal from each of the gamma ray sensors and in conjunction with certain constants established by the geometrical configuration of the sensors relative to the gamma ray source and the borehole diameter. Formation density is determined without regard to the radial position of the logging probe within the borehole in a measuring while drilling mode. 6 figs

  17. Brain anomalies induced by gamma irradiation in prenatal period

    International Nuclear Information System (INIS)

    Schmidt, S.L.

    1992-01-01

    Gamma irradiation has been utilized in order to produce cortical and callosal abnormalities. We have also checked for the presence of the aberrant longitudinal bundle in the brains of mice born acallosal due to prenatal irradiation is also checked. Pregnant mice were exposed to gamma irradiation from a 6 0 Co source at 16, 17 and 19 days of gestational age (E 16, E 17 and E 19) with total doses of 2 Gy and 3 Gy. At 60 days postnatal the offspring of irradiated animals were intra cardiac perfused, the brains were removed from the cranio and cut into coronal or para sagittal sections. (author)

  18. Modular gamma systems

    International Nuclear Information System (INIS)

    Millegan, D.R.; Nixon, K.V.

    1982-01-01

    Nuclear safeguards requires sensitive, easily operated instruments for rapid inspection of personnel and vehicles to ensure that no uranium or plutonium is being diverted. Two portable gamma-ray detection systems have been developed. The Modular Gamma System (MGS) is very sensitive and two or more systems can be connected for even better performance. The multiunit configuration can be deployed by motor vehicle for search of large areas too extensive to search on foot. The Programmable Rate Monitor (PRM) is less sensitive but much smaller and therefore is more suitable for search of vehicles, personnel, or smaller areas. The PRM is programmable, which implements measurement and alarm algorithms for individual applications

  19. Proprioceptive evoked gamma oscillations

    DEFF Research Database (Denmark)

    Arnfred, S.M.; Hansen, Lars Kai; Parnas, J.

    2007-01-01

    A proprioceptive stimulus consisting of a weight change of a handheld load has recently been shown to elicit an evoked potential. Previously, somatosensory gamma oscillations have only been evoked by electrical stimuli. We conjectured that a natural proprioceptive stimulus also would be able...... to evoke gamma oscillations. EEG was recorded using 64 channels in 14 healthy subjects. In each of three runs a stimulus of 100 g load increment in each hand was presented in 120 trials. Data were wavelet transformed and runs collapsed. Inter-trial phase coherence (ITPC) was computed as the best measure...

  20. Gamma-Ray Bursts

    Science.gov (United States)

    Pellizza, L. J.

    Gamma-ray bursts are the brightest transient sources in the gamma-ray sky. Since their discovery in the late 1960s, the investigation of the astrophysical sys- tems in which these phenomena take place, and the physical mechanisms that drive them, has become a vast and prolific area of modern astrophysics. In this work I will briefly describe the most relevant observations of these sources, and the models that describe their nature, emphasizing on the in- vestigations about the progenitor astrophysical systems. FULL TEXT IN SPANISH

  1. Gamma Ray Bursts

    Science.gov (United States)

    Gehrels, Neil; Meszaros, Peter

    2012-01-01

    Gamma-ray bursts (GRBs) are bright flashes of gamma-rays coming from the cosmos. They occur roughly once per day ,last typically lOs of seconds and are the most luminous events in the universe. More than three decades after their discovery, and after pioneering advances from space and ground experiments, they still remain mysterious. The launch of the Swift and Fermi satellites in 2004 and 2008 brought in a trove of qualitatively new data. In this review we survey the interplay between these recent observations and the theoretical models of the prompt GRB emission and the subsequent afterglows.

  2. Interferon Gamma-1b Injection

    Science.gov (United States)

    Interferon gamma-1b injection is used to reduce the frequency and severity of serious infections in people with chronic ... severe, malignant osteopetrosis (an inherited bone disease). Interferon gamma-1b is in a class of medications called ...

  3. Gamma knife surgery for craniopharyngioma

    International Nuclear Information System (INIS)

    Prasad, D.; Steiner, M.; Steiner, L.

    1995-01-01

    We present our results of Gamma Knife surgery for craniopharyngioma in nine patients. The current status of surgery, radiation therapy, intracavitary instillation of radionuclides and Gamma Knife surgery in the management of craniopharyngiomas is discussed. (author)

  4. CKM angle $\\gamma$ from LHCb

    CERN Multimedia

    Smith, Jackson

    2015-01-01

    Results of the latest $\\gamma$ combination from LHCb are presented, along with the six LHCb measurements used as inputs. In addition, the anticipated precision attainable for measuring $\\gamma$ after the LHCb Upgrade is outlined

  5. Investigations on Pasteurization of Cold Marinades by {sup 60}Co Gamma Rays; Recherches sur la Pasteurisation a Froid De Marinades par les Rayons Gamma du {sup 60}Co; Issledovaniya pasterizatsii kholodnykh marinadov gamma-luchami; Investigaciones Sobre la Pasteurizacion de Escabeches Frios por Irradiacion Gamma con {sup 60}Co

    Energy Technology Data Exchange (ETDEWEB)

    Schoenborn, W.; Kinkel, R J.; Hafferl, W. [Battelle Institut e.V., Frankfurt/Main, Federal Republic of Germany (Germany)

    1966-11-15

    'echelle hedonistique des qualites (neuf degres), ainsi que sur des essais differentiels (test du triangle), ont ete faits par un groupe d'experts. A 70 krad, le gout est encore acceptable; a 140 krad, un gout d'irradiation tres net est perceptible; a 280 krad, le gout est franchement desagreable. Une amelioration sensible du gout peut etre obtenue par une irradiation a basse temperature (-30 Degree-Sign C) et par l'addition d'acide ascorbique, de sorbitol et d'epices. Les experiences se poursuivent. (author) [Spanish] Los filetes de arenque en escabeche son un producto alimenticio sazonado por la accion del acido acetico y de la sal, que se vende en una salmuera picante con un 3% de sal y de acido acetico (pH 4). Como la nueva ley bromatologica alemana restringe temporalmente el empleo de hexametilenotetramina, aditivo conservador habitualmente utilizado, se ha investigado la pasteurizacion por medio de radiaciones ionizantes como un nuevo metodo de conservacion sin adicion de otros agentes. La descomposicion de este producto alimenticio era causada por bacterias lacticas heterofermentativas que descarboxilaban los aminoacidos liberados por las proteinas; la descomposicion se indujo por tratamiento con anhidrido carbonico. Los escabeches se envasaron en latas aplanadas que contenian unos 125 g y se sometieron, mientras se enfriaban,, a los rayos gamma emitidos por una fuente sumergida uee {sup 60}Co. La irradiacion prolongo el periodo de almacenamiento de estas conservas de escabeche. El periodo transcurrido, a 15 Degree-Sign C hasta que se procedio al tratamiento con Co{sub 2}, fue tres veces mayor que el habitual, para una dosis de irradiacion de 155 krad. El numero critico de 1 millon de germenes/ml a 15 Degree-Sign C se alcanzo tambien al cabo de un periodo tres veces superior al habitual, para una dosis de irradiacion de 160 krad. La DLgg de tres cepas aisladas de bacterias lacticas irradiadas en una solucion de sal y peptona fue de 113, 165 y 144 krad, respectivamente. Como a-15

  6. Recommendations guide for the correct prescription's tests of diagnosis by image; Guia de recomendaciones para la correcta solicitud de pruebas de diagnostico por imagen

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    The purpose of this guide is to protect the health of the population against the dangers of ionizing radiation. The unjustified studies involving exposure to radiation unnecessarily increases the cancer risk in the exposed population. Medical irradiations are the most important contribution to human exposure to ionizing radiation from artificial character. Since statistics indicate a growing trend in the number of practices as well as the number of facilities, the quality of those practices, its justification and its optimization are today a relevant topic to scientific societies and regulatory agencies. Since the adoption of the directive 97/43/EURATOM, and the realization of the Conference of Malaga most European countries have implemented action plans for radiation protection of patients, including the search for consensus on the optimization dose criteria and justification for the indication of the examinations. An example is the PR/118 guide for diagnosis studies requests. In this framework, two Conferences on Radiation Protection of Patient were held in our country in which 'Working Groups' were organized on the following topics: Radiodiagnosis, Radiotherapy, Nuclear Medicine and Radioprotection of the Pregnant Woman. Systematic actions that received strong institutional support of the Argentine Society of Radiology began and ended with the elaboration of a 'Program for Radiological Protection Patient' which is being implemented. [Spanish] El objetivo de esta Guia es la proteccion de la salud de la poblacion frente a los riesgos derivados de las radiaciones ionizantes. La realizacion injustificada de estudios que impliquen exposicion a la radiacion aumenta innecesariamente el riesgo de cancer en la poblacion expuesta. Las irradiaciones medicas son la contribucion mas importante a la exposicion humana a las radiaciones ionizantes de caracter artificial. Ya que las estadisticas indican una tendencia creciente en el numero de practicas asi como la cantidad de

  7. Ultrasonography X gamma radiography

    International Nuclear Information System (INIS)

    Mello Campos, A.M. de

    1989-01-01

    The accumulated experience in the last ten years of substitution to essays by gamma radiography to essay by ultrasonography, starting of the systematic comparison and tabulation of the results obtained by both essays applied in welding joints, in field, in steel pipelines of the SABESP. (V.R.B.)

  8. Gamma knife radiosurgery

    International Nuclear Information System (INIS)

    Kobayashi, Tatsuya; Mori, Yohsimasa; Kida, Yoshihisa

    2003-01-01

    Gamma knife radiosurgery has become a new treatment modality in the field of neurosurgery since the first gamma knife was brought into Japan in 1990. Advances in applications of new indications and long-term results have been continued to evolve during the past 12 years. Based on the experience of more than 4,500 cases treated by gamma knife at Komaki City Hospital, long-term results of arteriovenous malformations (AVMs), metastatic brain tumors, acoustic neurinomas, meningiomas and trigeminal neuralgias are presented. Radiosurgery has become a novel treatment modality, especially for AVM, acoustic neurinoma and meningioma, which were once only treatable by conventional surgery, and shows a high cure rate in AVM cases and high control rate in benign tumors without major complications. The effects of radiosurgery for metastatic brain tumors have been thought to be superior to fractionated radiotherapy due to high response and control rates, and patients showed improved quality of life although no prolongation of the life span was obtained. Gamma knife treatment for trigeminal neuralgia has been shown to be effective and less invasive than microvascular decompression, and is useful for cases resistant to conventional therapies and as an initial treatment as well. (author)

  9. Automated gamma counters

    International Nuclear Information System (INIS)

    Regener, M.

    1977-01-01

    This is a report on the most recent developments in the full automation of gamma counting in RIA, in particular by Messrs. Kontron. The development targets were flexibility in sample capacity and shape of test tubes, the possibility of using different radioisotopes for labelling due to an optimisation of the detector system and the use of microprocessers to substitute software for hardware. (ORU) [de

  10. Gamma cardio 82

    International Nuclear Information System (INIS)

    Itti, R.

    1982-01-01

    New trends in nuclear cardiology are briefly presented supported by a large bibliography. The following topics are reviewed: new tracers of myocardial perfusion and metabolism; quantitative analysis of cardiac function; nuclear stethoscope; gamma emission tomography; diagnostic value of cardiac dynamic tests (at rest and during exercise), pharmacological tests; new clinical applications of cardiovascular nuclear medicine [fr

  11. Marine gamma spectrometric survey

    International Nuclear Information System (INIS)

    Kostoglodov, V.V.

    1979-01-01

    Presented are theoretical problems physical and geochemical prerequisites and possibilities of practical application of the method of continuous submarine gamma-spectrometric survey and radiometric survey destined for rapid study of the surface layer of marine sediments. Shown is high efficiency and advantages of this method in comparison with traditional and widely spread in marine geology methods of bottom sediments investigation

  12. Industrial radiography. Gamma radiography

    International Nuclear Information System (INIS)

    Menetrier, J.

    1975-01-01

    Informations are given on gamma radiodefectology regulations, entire references and main dispositions applicable to each state of the European Economic Community. The content includes previous arrangements for source acquisition, holding and use of the sources, transport, accidents, civil liability of the source holder, person insurance against radiation hazards and contamination, property insurance, penal liability of the source holder

  13. Introscopy using gamma sources

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Leonov, B.I.; Najorov, A.N.; Smirnov, N.N.; Firstov, V.G.

    1978-01-01

    A method is described of working with standard 170 Tm, 75 Se, 192 Ir, 137 Cs and 60 Co sources at the activity of 1-4000 Ci, during television gamma introscopy of steel products. Experiments involving the RI-10T introscope are carried out to determine prospects of using various radiation sources. The results of using X-ray instruments for control of steel products are also shown for comparison. In introscopy of X-rayed steel products over 25 mm thick, spreading of the edge of the detected groove image is shown to be comparable when using X radiation and gamma radiation of standard sources. Sensitivity of control by fluorographic introscope in X-raying and gamma irradiation of products over 25 mm thick will presumably be the same owing to the detector storage capacity. The use of commercial gamma flaw detecting instruments together with a television introscope permits to reliably reveal defects of 0.5-2.0 mm in size, eliminating possible instability of operation of X-ray instruments, particularly in field conditions

  14. Gamma apparatuses for radiotherapy

    International Nuclear Information System (INIS)

    Sul'kin, A.G.

    1986-01-01

    Scientific and technical achievements in development and application of gamma therapeutic apparatuses for external and intracavity irradiations are generalized. Radiation-physical parameters of apparatuses providing usability of progressive methods in radiotherapy of onclogical patients are given. Optimization of main apparatus elements, ensurance of its operation reliability, reduction of errors of irradiation plan reproduction are considered. Attention is paid to radiation safety

  15. Gamma ray calibration system

    International Nuclear Information System (INIS)

    Rosauer, P.J.; Flaherty, J.J.

    1981-01-01

    This invention is in the field of gamma ray inspection devices for tubular products and the like employing an improved calibrating block which prevents the sensing system from being overloaded when no tubular product is present, and also provides the operator with a means for visually detecting the presence of wall thicknesses which are less than a required minimum. (author)

  16. para palmito

    Directory of Open Access Journals (Sweden)

    Francisco Paulo Chaimsohn

    2007-01-01

    Full Text Available Densidades de siembra, arreglos espaciales y fertilización en pejibaye (Bactris gasipaes cv Diamantes-10 para palmito. La investigación se llevó a cabo en la Estación Experimental Los Diamantes (Guápiles, Costa Rica, el 3 de octubre del 2003, cuyo objetivo fue la evaluación del efecto de diferentes densidades de siembra (3.333, 5.000 y 6.666 plantas/ha, arreglos espaciales, y diversos métodos de fertilización (química, orgánica, sobre el crecimiento de las plantas de pejibaye para producción de palmito. Se consideraron las variables diámetro y altura del tallo primario y el número de hojas y rebrotes como indicadores de producción. El período de evolución abarcó sólo los primeros 25 meses de crecimiento en el campo. El número de hojas, la altura y el diámetro del tallo no mostraron diferencias de respuesta relevantes. Sólo el número de rebrotes disminuyó al aumentar la densidad de la población, cuando se midió a los 15 meses de edad. El efecto de la fertilización se hizo evidente después de la primera cosecha, realizada a los 20 meses, debido al aumento de la competencia entre plantas, ahora más desarrolladas. Fue entonces cuando la fertilización química indujo la producción de un mayor número y vigor de los rebrotes. Sin embargo, las prácticas evaluadas 25 meses después de la siembra, no habían infl uido hasta ese momento en el número de palmitos cosechados, ni tampoco había afectado las características físicas de los sectores foliar y caulinar del palmito.

  17. Cosmical sources of gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Kuchowicz, B [Warsaw Univ. (Poland)

    1974-01-01

    A brief historical outline of the X-ray and ..gamma..-ray astronomies is given first, then a summary of the recent status of X-ray astronomy follows. Further chapters include information on ..gamma..-ray sources in the solar system, in our Galaxy, and beyond it. In discussing linear gamma spectra attention is paid to the possibility of studying explosive nucleo-synthesis by observation of gamma lines from supernova remnants, etc. Questions of the isotropic gamma background are discussed at the end of the survey.

  18. Determinação da dose de radiação gama para reduzir a população de Salmonella spp em carne de frango Determination of gamma radiation doses to reduce Salmonella spp in chiken meat

    Directory of Open Access Journals (Sweden)

    A.F. Santos

    2003-08-01

    Full Text Available O consumo de carne de frango contaminada com Salmonella é uma causa importante de salmonelose em todo o mundo. Essa doença transmitida por alimentos, é um problema de saúde pública e causa de perdas econômicas substanciais. O processo de irradiação é um método eficiente de conservação de alimentos por reduzir o número de microrganismos patogênicos e deteriorantes, sem que as características organolépticas e nutricionais do alimento sejam alteradas significativamente. Os objetivos desta pesquisa foram determinar o valor D10 de Salmonella Typhimurium ATCC 14028, inoculada em sobrecoxas de frango, e recomendar uma dose de radiação para ser aplicada a esse alimento a fim de torná-lo seguro do ponto de vista microbiológico. O valor D10 foi calculado a partir da curva de sobreviventes dessa bactéria em sobrecoxas de frango, após terem sido expostas às doses de 0kGy; 0,1kGy; 0,2kGy; 0,3kGy; 0,5kGy; 0,6kGy; 0,7kGy e 0,8kGy. O valor D10 variou de 0,241kGy a 0,480kGy. Considerando o maior valor D10 e o maior nível de contaminação de Salmonella spp encontrado em sobrecoxas de frango - 0,4NMP/g - adquiridas em feiras livres da cidade de São Paulo, a dose de radiação gama recomendada para garantir a segurança do produto em relação à presença de Salmonella spp é de 3,8kGy.The consumption of chicken meat contaminated with Salmonella spp is an important cause of salmonellosis worldwide. This food-borne disease is a public health problem and causes substantial economical loss. Irradiation process is an effective method for food preservation because it causes no significant change in organoleptic and nutritional food characteristics and destroys pathogenic and spoilage microorganisms. D10 values were calculated through the number of survivors for S. Typhimurium ATCC 14028, inoculated in chicken thighs, after being irradiated with different doses of gamma radiation - 0.0kGy; 0.1kGy; 0.2kGy; 0.3kGy; 0.5kGy; 0.7kGy and 0.8kGy . D10

  19. Determination of Fallout Radionuclides in Environmental Samples by Gamma-Ray Spectrometry; Mesure Spectrometrique Gamma des Radionucleides de Retombee Presents dans des Echantillons du Millieu; Opredelenie radioizotopov radioaktivnykh osadkov v probakh iz okruzhayushchej sredy pri pomoshchi spektrometrii gamma-luchej; Determinacion, por Espectrometria Gamma, de los Radionuclidos de Precipitaciones en Muestras del Medio Ambiente

    Energy Technology Data Exchange (ETDEWEB)

    Ward, G. M.; Johnson, J. E.; Wilson, D. W. [Department of Animal Science, Colorado State University, Fort Collins, CO (United States)

    1965-10-15

    -Nb, gracias a su relativa abundancia. Los fotopicos correspondientes al {sup 131}Cs, el {sup 54}Mn y el {sup 125}Sb aparecfan totalmente obscurecidos, y en la representacifin de los nueclidos de eneigias mas bajas ({sup 141,144}Ce y {sup 103}Ru) influfan considerablemente los efectos Compton de nuclidos que emiten radiaciones de energia mas elevada. Hay que tener en cuenta que la separacifin del espectro no ofrece garantfas si los fotopicos no aparecen bien visibles. Cuando las interferencias impiden la determinacion directa del {sup 137}Cs y de otros nuclidos, el almacenamiento de las muestras hasta que se desintegran el {sup 95}Zr-Nb (T{sub Vulgar-Fraction-One-Half} = 65 d) y del {sup 103}Ru (T{sub Vulgar-Fraction-One-Half} = 40 d) permite identificar los fotopicos de los nuclidos restantes. El {sup 137}Cs y el {sup 54}Mn pueden separarse qufmicamente digiriendo las muestras en NaOH concentrado (el {sup 137}Cs de las precipitaciones sfilo se disuelve enteramente en bases fuertes) y filtrando el liquido, con lo que se separa el 95% aproximadamente del {sup 95}Zr-Nb. La elucion del concentrado de agua de Uuvia de las columnas con NH{sub 4}NO{sub 3} 1 M eliminfi cuantitativamente el {sup 137}Cs y separo eficazmente las actividades correspondientes al {sup 95}Zr-Nb y al {sup 54}Mn. Una vez que se hicieron visibles todos los fotopicos, bien por desintegracion o bien por separacifin qufmica, fue posible evaluar cuantitativamente cada radionuclido por calibracion individual y calculo de los efectos Compton respectivos. Las ecuaciones resultantes se resolvieron con ayuda de una calculadora electronica IBM 1620 y de un programa preparado para hallar la concentracion de cada uno de los 9 nuclidos anteriormente mencionados. Ese mismo programa se utilize para determinar el {sup 137}Cs y el {sup 40}K contenidos en la leche, la carne y la orina, determinacion mas sencilla y que, por ello, entrana margenes de error mas estrechos. (author) [Russian] S maja 1962 goda i do nastojashhego

  20. Precise measurement of {gamma}(K{yields}e {nu}({gamma}))/{gamma}(K{yields}{mu} {nu}({gamma})) and study of K{yields}e {nu} {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Ambrosino, F.; Massarotti, P.; Meola, S.; Napolitano, M. [Dipartimento di Scienze Fisiche dell' Universita ' ' Federico II' ' , Napoli (Italy); INFN Sezione di Napoli, Napoli (Italy); Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bloise, C.; Bossi, F.; Capon, G.; Capussela, T.; Ciambrone, P.; De Lucia, E.; De Simone, P.; Dreucci, M.; Felici, G.; Gatti, C.; Giovannella, S.; Jacewicz, M.; Lanfranchi, G.; Miscetti, S.; Moulson, M.; Murtas, F.; Palutan, M.; Santangelo, P.; Sciascia, B.; Sibidanov, A.; Spadaro, T.; Venanzoni, G. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Archilli, F. [Dipartimento di Fisica dell' Universita ' ' Tor Vergata' ' , Rome (Italy); INFN Sezione di Roma Tor Vergata, Rome (Italy); Beltrame, P.; Denig, A.; Mueller, S. [Johannes Gutenberg-Universitaet, Institut fuer Kernphysik, Mainz (Germany); Bini, C.; De Santis, A.; De Zorzi, G.; Di Domenico, A.; Fiore, S.; Franzini, P.; Gauzzi, P. [Dipartimento di Fisica dell' Universita ' ' La Sapienza' ' , Rome (Italy); INFN Sezione di Roma, Rome (Italy); Bocchetta, S.; Ceradini, F.; Di Micco, B.; Nguyen, F. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); INFN Sezione di Roma Tre, Rome (Italy); Branchini, P.; Graziani, E.; Passeri, A.; Tortora, L. [INFN Sezione di Roma Tre, Rome (Italy); Capriotti, D. [Dipartimento di Fisica dell' Universita ' ' Roma Tre' ' , Rome (Italy); Di Donato, C. [INFN Sezione di Napoli, Napoli (Italy); Kulikov, V. [Institute for Theoretical and Experimental Physics, Moscow (Russian Federation); Lee-Franzini, J. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); State University of New York, Physics Department, Stony Brook (United States); Martini, M.; Patera, V.; Versaci, R. [Laboratori Nazionali di Frascati dell' INFN, Frascati (Italy); Dipartimento di Energetica dell' Universita ' ' La Sapienza' ' , Rome (Italy); Valente, P. [INFN Sezione di Roma, Rome (Italy)

    2009-12-15

    We present a precise measurement of the ratio R{sub K}={gamma}(K{yields}e{nu}({gamma}))/{gamma}(K{yields}{mu}{nu}({gamma})) and a study of the radiative process K{yields}e{nu}{gamma}, performed with the KLOE detector. The results are based on data collected at the Frascati e{sup +}e{sup -} collider DA {phi}NE for an integrated luminosity of 2.2 fb{sup -1}. We find R{sub K}=(2.493{+-}0.025{sub stat}{+-}0.019{sub syst}) x 10{sup -5}, in agreement with the Standard Model expectation. This result is used to improve constraints on parameters of the Minimal Supersymmetric Standard Model with lepton flavor violation. We also measured the differential decay rate d {gamma}(K{yields}e{nu}{gamma})/dE{sub {gamma}} for photon energies 10gamma}}<250 MeV. Results are compared with predictions from theory. (orig.)

  1. Non-Destructive Methods for Determining Burn-Up in Nuclear Fuel; Methodes Non Destructives d'Evaluation du Taux de Combustion dans le Combustible Nucleaire; Metody opredeleniya vygoraniya v yadernom toplive bez razrusheniya obraztsa; Metodos No Destructivos para Determinai el Grado de Combustion de los Elementos Combustibles Nucleares

    Energy Technology Data Exchange (ETDEWEB)

    McGonnagle, W. J. [Illinois Institute of Technology, Chicago, IL (United States)

    1966-02-15

    repercute en los calculos que pueden efectuarse. Otra de las dificultades de la determinacion no destructiva consiste en la presencia de intensos campos de radiaciones que contribuyen al 'ruido' defondo dela medicion. La preparacion de patrones eficaces es dificil. Aunque en el estado actual de la tecnica carezcan de la precision deseada, los metodos no destructivos para determinar el grado de combustion resultan utiles sobre todo cuando es preciso obtener rapidamente valores aproximados sin que el costo de la operacion resulte excesivo. Para determinar el grado de combustion se han empleado, se estan estudiando o se han propuesto diversos metodos no destructivos. Se han empleado varios tipos de espectrometro -el de cristal curvo, el magnetico de Compton, el de coincidencia de Compton y el de centelleo- para analizar la radiacion gamma proveniente del material radiactivo formado durante el proceso de fision. Entre otros metodos no destructivos cabe mencionar la activacion de laminas, la transmision neutronica, el analisis por activacion, la medicion de rayos gamma de captura y la medicion de neutrones rapidos y retardados. En la memoria se exponen los principios basicos de cada uno de los instrumentos y de los metodos mencionados y se formulan observaciones sobre su sensibilidad y sus inconvenientes. . El autor propone metodos no destructivos basados en el empleo de isotopos estables producidos durante el proceso de fision. Con el empleo de esos isotopos los datos relativos a las irradiaciones precedentes tienen una importancia secundaria y los relativos al tiempo de enfriamiento no tienen ninguna. Ademas, para los productos estables de fision se dispone de datos nucleares mas precisos. Entre los isotopos estables producidos durante el proceso de fision, los mas utiles parecen ser el circonio, el molibdeno, el rutenio y el neodimio. En la memoria se analizan todos los metodos propuestos. (author) [Russian] Metody kolichestvennogo izmerenija vygoranija toplivnyh jelementov v

  2. Gamma counter calibration system

    International Nuclear Information System (INIS)

    1977-01-01

    A method and apparatus are described for the calibration of a gamma radiation measurement instrument to be used over any of a number of different absolute energy ranges. The method includes the steps of adjusting the overall signal gain associated with pulses which are derived from detected gamma rays, until the instrument is calibrated for a particular absolute energy range; then storing parameter settings corresponding to the adjusted overall signal gain, and repeating the process for other desired absolute energy ranges. The stored settings can be subsequently retrieved and reapplied so that test measurements can be made using a selected one of the absolute energy ranges. Means are provided for adjusting the overall signal gain and a specific technique is disclosed for making coarse, then fine adjustments to the signal gain, for rapid convergence of the required calibration settings. (C.F.)

  3. Gamma-ray bursts

    CERN Document Server

    Wijers, Ralph A M J; Woosley, Stan

    2012-01-01

    Cosmic gamma ray bursts (GRBs) have fascinated scientists and the public alike since their discovery in the late 1960s. Their story is told here by some of the scientists who participated in their discovery and, after many decades of false starts, solved the problem of their origin. Fourteen chapters by active researchers in the field present a detailed history of the discovery, a comprehensive theoretical description of GRB central engine and emission models, a discussion of GRB host galaxies and a guide to how GRBs can be used as cosmological tools. Observations are grouped into three sets from the satellites CGRO, BeppoSAX and Swift, and followed by a discussion of multi-wavelength observations. This is the first edited volume on GRB astrophysics that presents a fully comprehensive review of the subject. Utilizing the latest research, Gamma-ray Bursts is an essential desktop companion for graduate students and researchers in astrophysics.

  4. Gamma ray camera

    International Nuclear Information System (INIS)

    Wang, S.-H.; Robbins, C.D.

    1979-01-01

    An Anger gamma ray camera is improved by the substitution of a gamma ray sensitive, proximity type image intensifier tube for the scintillator screen in the Anger camera. The image intensifier tube has a negatively charged flat scintillator screen, a flat photocathode layer, and a grounded, flat output phosphor display screen, all of which have the same dimension to maintain unit image magnification; all components are contained within a grounded metallic tube, with a metallic, inwardly curved input window between the scintillator screen and a collimator. The display screen can be viewed by an array of photomultipliers or solid state detectors. There are two photocathodes and two phosphor screens to give a two stage intensification, the two stages being optically coupled by a light guide. (author)

  5. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.; Schlosser, P.A.; Steidley, J.W.

    1980-01-01

    A detailed description is given of a novel gamma camera which is designed to produce superior images than conventional cameras used in nuclear medicine. The detector consists of a solid state detector (e.g. germanium) which is formed to have a plurality of discrete components to enable 2-dimensional position identification. Details of the electronic processing circuits are given and the problems and limitations introduced by noise are discussed in full. (U.K.)

  6. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  7. A gamma scintillation spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    Symbalisty, S

    1952-07-01

    A scintillation type gamma ray spectrometer employing coincidence counting, designed and built at the Physics Department of the University of Western Ontario is described. The spectrometer is composed of two anthracene and photomultiplier radiation detectors, two pulse analyzing channels, a coincidence stage, three scalers and a high voltage stabilized supply. A preliminary experiment to test the operation of the spectrometer was performed and the results of this test are presented. (author)

  8. Gamma camera display system

    International Nuclear Information System (INIS)

    Stout, K.J.

    1976-01-01

    A gamma camera having an array of photomultipliers coupled via pulse shaping circuitry and a resistor weighting circuit to a display for forming an image of a radioactive subject is described. A linearizing circuit is coupled to the weighting circuit, the linearizing circuit including a nonlinear feedback circuit with diode coupling to the weighting circuit for linearizing the correspondence between points of the display and points of the subject. 4 Claims, 5 Drawing Figures

  9. Preservation and gamma irradiation

    International Nuclear Information System (INIS)

    Ramiere, R.

    1991-01-01

    The paper reviews briefly the application of gamma radiation to preservation of cultural objects for disinsectization, disinfection and strengthening of materials such as wood or stone by impregnation with a liquid resin and in situ polymerization. As heavy equipment is required two facilities are specialized a 1000 T Bq cobalt 60 source at Grenoble (France) and 100 T Bq one at Rostoky (Czechoslovakia). Examples of treated objects are given [fr

  10. Gamma radiation in apartments

    International Nuclear Information System (INIS)

    Grindborg, J.-E.

    1983-05-01

    This investigation forms the basis for the description of methods for the detection of gamma radiation. The aim is to control that the dose limit will not exceed 50 μR/h in a room where people reside. The distribution of dose rates in different rooms has been calculated and the results have been compared with experimental data. Various instruments have been calibrated and their specifications are discussed. (G.B.)

  11. Planned Procedures for Fast Determination of Radiation Levels and Personnel Dosimetry in Connection with Radiological Accidents; Methodes de Dosimetrie Rapide du Personnel en Cas d'Accident Radiologique; 041f 041b 0410 041d 0414 ; Servicio Organizado de Determinacion Rapida de los Niveles de Radiacion y de Dosimetria del Personal en Caso de Accidente Radiologico

    Energy Technology Data Exchange (ETDEWEB)

    Edvardsson, K. -A.; Wahlberg, T. [AB Atomenergi, Studsvik (Sweden)

    1965-06-15

    medios de comunicacion con el interior y con el exterior. En materia de dosimetria individual, interesa, a la vez obtener lo antes posible los datos preliminares aproximados de la intensidad de la exposicion interna y externa, asi como, dentro de un plazo prudencial, datos bastante exactos, de la exposicion a que ha estado expuesta cada persona. Diversos equipos de determinacion de dosis, conocidos con el nombre de patrullas de reconocimiento, recorren los diversos sectores del recinto de la instalacion a fin de efectuar una evaluacion general de los riesgos. Esas patrullas que entran en accion tan pronto como se recibe la alarma estan provistas de instrumentos portatiles y recorren en automovil una serie de itinerarios previamente determinados en el emplazamiento. Los ensayos practicos realizados han puesto de manifiesto que las informaciones reunidas por las diversas patrullas llegan a la oficina central transcurridos 10-15 min despues de darse la alarma, permitiendo obtener una vision clara de los niveles de radiacion dentro y fuera de los diversos edificios. Los aparatos portatiles incluyen dispositivos para muestreo rapido del aire que funcionan segun el principio del eyector de aire. Las dosis individuales de irradiacion externa se evaluan con ayuda de dosimetros de pelicula, por activacion de dosimetros de criticidad, asi como por analisis de la actividad del pelo y de la sangre. La contaminacion interna se determina mediante antropogammametria y analisis radiometrico de las excreta. Para delimitar los campos de radiacion creados por un accidente, existen diversos puntos fijos de control equipados con dosimetros de varios tipos, a cuya lectura se procede lo antes posible despues de producirse el supuesto accidente. (author) [Russian] Obshhestvo po atomnoj jenergii Shvecii imeet special'nuju avarijnuju organizaciju, kotoraja nachinaet funkcionirovat' kak tol'ko poluchen signal o tom, chto sozdalos' chrezvychajnoe polozhenie v svjazi s bol'shoj radiacionnoj opasnost

  12. Gamma surgery for hemangiopericytomas

    International Nuclear Information System (INIS)

    Payne, B.R.; Prasad, D.; Steiner, M.; Steiner, L.

    2000-01-01

    A retrospective analysis of a consecutive series of 12 patients with 15 intracranial hemangiopericytomas treated at the University of Virginia using gamma surgery is presented. Clinical and radiographic follow up of 3 to 56 months is available for 10 patients with 12 tumors. There was one tumor present at the time of initial gamma surgery in each patient. Two new tumors occurred in patients previously treated. Nine of the tumors decreased in volume and three remained stable. Four of the nine tumors that shrank later progressed at an average of 22 months after treatment. Of the tumors that decreased in volume and have not progressed, the response has been for an average of 11 months. The follow-up for two tumors that remained unchanged was 10 and 34 months (average 22 months). A third tumor was unchanged at 42 months but the patient died of new disease adjacent to the treated area in the anterior skull base. There were no complications and the quality of life following the procedure was maintained or improved in every case. Gamma surgery is effective in palliating the patients by decreasing tumor volume and delaying recurrence. (author)

  13. gamma. radiation of ionium

    Energy Technology Data Exchange (ETDEWEB)

    Curie, I

    1948-12-08

    Following the work of Ward (Proc Cambridge Phil Soc 35 322(1939)), the ..gamma..-radiation of ionium (from an IoTh preparation) was studied with the aid of Ta and W screens, and an aluminum counter. The screen measurements confirmed Ward's findings of two radiations, of 68 keV and of about 200 keV. The number of quanta per second of each radiation was determined with the counter, which has been calibrated on certain L lines of radium. The global quanta number of L lines of ionium was also determined. The results were as follows: 0.7 quanta ..gamma.. of 68 keV for 100 ..cap alpha..-particles; 0.2 quanta ..gamma.. of 200 keV for 100 ..cap alpha..-particles; 10 quanta L for 100 ..cap alpha..-particles. These data, which show an important internal conversion, agree with the findings of Teillac (Compt Rend 227 1227 (1948)), who investigated the ..beta..-radiation of ionium. It is the radiation 68 keV which is highly converted. On the other hand, these results do no agree with the data on the fine structure of ionium found by Rosenblum, Valadares, and Vial (Compt Rend 227 1088(1948)).

  14. Apparatus for gamma radiography

    International Nuclear Information System (INIS)

    1983-06-01

    The aim of the present standard is to fix the rules for the construction of gamma radiography instrumentation without prejudice to the present regulations. These apparatus have to be fitted with only sealed sources conformable to the experimental standard M 61-002. The present standard agrees with the international standard ISO 3999 of 1977 dealing with the same subject. Nevertheless, it is different on the three main following points: it does not accept the same limits of absorbed dose rates in the air calculated on the external surface of projectors; it precribes tightness, bending, crushing and tensile tests for some components of the gamma radiography it prescribes tests of endurance and resistance to breaking for the locking systems of the gamma radiography apparatus. The present standard also specifies the following points: symbols and indications to put on projectors and on the source-holder; identification of the source contained in the projector; and, accompanying documents. The regulation references are given in annexe [fr

  15. Medical response guide for the initial phase of a radiological emergency; Guia para la respuesta medica en la fase inicial de una emergencia radiologica

    Energy Technology Data Exchange (ETDEWEB)

    Vazquez, Marina A; Perez, Maria del R

    2007-07-01

    In case of a sanitary emergency, the local community and its health care system are the first aid providers. Therefore, preparedness through education and training programs would allow emergency systems to provide an appropriate first medical response. The main objective of this guide is to give basic guidelines for the medical response management after situations involving radioactive materials, in an easy and simple way. The information contained in this guide is addressed to health care personnel of any local assistance center. (author) [Spanish] Las emergencias que afecten a un numero importante de personas y que tengan como protagonistas agentes 'no convencionales' como lo son las radiaciones ionizantes, deben ser abordadas mediante la implementacion de programas sanitarios especiales. En una situacion de emergencia, generalmente los primeros en proporcionar la ayuda, son la comunidad local y su sistema de salud. Por ello la preparacion previa local, a traves de la capacitacion y el entrenamiento permitira brindar una respuesta inicial adecuada que se articule con un sistema de respuesta en emergencias escalonado y de complejidad creciente. Esto requiere la participacion de las autoridades de salud en cada uno de los niveles de atencion, asi como apoyo de otros sectores para desarrollar sus planes de preparacion y respuesta. La presente guia, como instrumento de capacitacion, tiene como objetivo primario brindar las herramientas basicas para el manejo de la respuesta medica en una situacion de emergencia que involucre material radiactivo, en un lenguaje claro y sencillo, dirigida al personal de salud de todos los centros asistenciales locales. (autor)

  16. Human exposition to non ionizing electromagnetic radiations. Legislation and base stations measurements Exposición humana a las radiaciones electromagnéticas no ionizantes. Legislación y medidas de estaciones base

    Directory of Open Access Journals (Sweden)

    Antonio García Pino

    2004-12-01

    Full Text Available This work deals about measurement procedures of non-ionizing radiations and their recorded levels in practice. The analyzed radiation sources cover the most common broadcasting media such as AM and FM transmissions and the GSM mobile telephony base stations. These sources currently radiate locations with high density of population. Spanish radiation level regulations are briefly described and some possible improvements are pointed out. The measurement results are discussed.Este trabajo trata sobre los procedimientos de medida de las radiaciones no ionizantes y sus niveles registrados en medidas reales. Las fuentes de radiación analizadas cubren los medios de radiodifusión más corrientes, tales como las transmisiones AM y FM y también las estaciones base de telefonía móvil GSM. Estas fuentes habitualmente radian sobre áreas con alta densidad de población. Se describe brevemente el marco legal que regula los niveles de radiación en España y se señalan algunas posibles mejoras. Se valorarán los resultados encontrados en las medidas.

  17. Results of the Service of External Dosimetry of the Centro de Proteccion e Higiene de las Radiaciones (CPHR), Cuba during the biennium 2010 - 2011; Resultados del servicio de dosimetria externa del CPHR durante el bienio 2010-2011

    Energy Technology Data Exchange (ETDEWEB)

    Molina Perez, Daniel; Verdecia Sanchez, Maribel; Castro Soler, Ailza; Farrada Neyra, Yamilia, E-mail: daniel@cphr.edu.cu [Laboratorio de Dosimetria Externa (LDE), Centro de Proteccion e Higiene de las Radiaciones (CPHR), La Habana (Cuba)

    2013-07-01

    The Service of Personal Dosimetry of the External Dosimetry Laboratory of the Centro de Proteccion y Higiene de las Radiaciones - CPHR of Cuba works with an automatic RADOS TLD system and includes the surveillance of the doses of whole body and extremities for photon radiation. The work presents the results of the service in the period 2010-2011, showing data related to the number and distribution of workers monitored for areas. The levels of occupational exposure area analyzed using various indicators such as: annual average dose for areas, number of workers who receive annual doses greater than zero, distribution of workers by dose intervals, and others. These indicators are compared with previous periods and with the values published by the UNSCEAR. In general, the average annual dose for all areas was less than 1 mSv for whole body and 3 mSv for hands. The number of exposed workers experienced significant variation from one year to another, considerably decreasing from 60% to 12% of the total. The work presents an analysis of this behavior and highlights that the country guarantees the personal dosimetry to 100% of exposed workers and that the results of the occupational exposure are within the established requirements.

  18. Lunar based gamma ray astronomy

    International Nuclear Information System (INIS)

    Haymes, R.C.

    1985-01-01

    Gamma ray astronomy represents the study of the universe on the basis of the electromagnetic radiation with the highest energy. Gamma ray astronomy provides a crucial tool for the understanding of astronomical phenomena, taking into account nucleosynthesis in supernovae, black holes, active galaxies, quasars, the sources of cosmic rays, neutron stars, and matter-antimatter annihilation. Difficulties concerning the conduction of studies by gamma ray astronomy are related to the necessity to perform such studies far from earth because the atmosphere is a source of gamma rays. Studies involving the use of gamma ray instruments in earth orbit have been conducted, and more gamma ray astronomy observations are planned for the future. Imperfections of studies conducted in low earth orbit could be overcome by estalishing an observatory on the moon which represents a satellite orbiting at 60 earth radii. Details concerning such an observatory are discussed. 5 references

  19. Sequential Analysis of Gamma Spectra

    International Nuclear Information System (INIS)

    Fayez-Hassan, M.; Hella, Kh.M.

    2009-01-01

    This work shows how easy one can deal with a huge number of gamma spectra. The method can be used for radiation monitoring. It is based on the macro feature of the windows XP connected to QBASIC software. The routine was used usefully in generating accurate results free from human errors. One hundred measured gamma spectra were fully analyzed in 10 minutes using our fast and automated method controlling the Genie 2000 gamma acquisition analysis software.

  20. Applied gamma-ray spectrometry

    CERN Document Server

    Dams, R; Crouthamel, Carl E

    1970-01-01

    Applied Gamma-Ray Spectrometry covers real life application of the gamma-ray and the devices used in their experimental studies. This book is organized into 9 chapters, and starts with discussions of the various decay processes, the possible interaction mechanisms of gamma radiation with matter, and the intrinsic and extrinsic variables, which affect the observed gamma-ray and X-ray spectra. The subsequent chapters deal with the properties and fabrication of scintillation detectors, semiconductor detectors, and proportional gas counters. These chapters present some of the most widely utilized

  1. Joining of Gamma Titanium Aluminides

    National Research Council Canada - National Science Library

    Baeslack, William

    2002-01-01

    .... Although organized and presented by joining process, many of the observations made and relationships developed, particularly those regarding the weldability and welding metallurgy of gamma titanium...

  2. Simultaneous beta and gamma spectroscopy

    Science.gov (United States)

    Farsoni, Abdollah T.; Hamby, David M.

    2010-03-23

    A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

  3. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment developed for the renewal of the network of stations automatic monitoring environmental radiation of the Generalitat of Catalunya; Calibracion y estudio de las capacidades de medida de los equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigilancia radiologia ambiental de la Generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2014-10-01

    The renewal of the automatic environmental radiation surveillance network of the Generalitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. the monitors use scintillation crystals, either Na(TI) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentration for some isotopes. (Author)

  4. Calibration and study of the measurement capabilities of real-time gamma spectrometry equipment, developed for the renewal of the network of automatic stations for environmental radiological surveillance of the Generalitat de Catalunya; Calibracion y estudio de las capacidades de medida de loes equipos de espectrometria gamma en tiempo real desarrollados para la renovacion de la Red de Estaciones Automaticas de vigencia radiologica ambiental de la generalitat de Catalunya

    Energy Technology Data Exchange (ETDEWEB)

    Casanovas, R.; Prieto, E.; Salvado, M.

    2013-07-01

    The renewal of the automatic environmental radiation surveillance network of the Gereralitat of Catalunya has been carried out through the development and implementation of gamma-spectrometry-based equipment. The monitors use scintillation cristals, either NaI(Tl) or LaBr{sub 3}(Ce) and currently, there are 3 types of equipment: water radioactivity monitors, aerosols on a particulate filter monitors and direct measurement monitors. In this paper, we expose the basic features of its operation, the details of their calibration and the minimum detectable activity concentrations for some isotopes.

  5. El uso de la neuromodulación para el tratamiento del temblor

    Science.gov (United States)

    Bendersky, Damián; Ajler, Pablo; Yampolsky, Claudio

    2014-01-01

    Introducción: El temblor puede ser un desorden incapacitante y el tratamiento de primera línea para estos pacientes es farmacológico. Sin embargo, este tratamiento puede llevar a una reducción satisfactoria del temblor en sólo el 50% de los pacientes con temblor esencial. La talamotomía era el tratamiento de elección para el temblor refractario al tratamiento médico hasta que comenzó a utilizarse la estimulación cerebral profunda (ECP) del núcleo ventral intermedio (Vim) del tálamo. En la actualidad, raramente se realiza la talamotomía. Métodos: Este artículo es una revisión no sistemática de las indicaciones, resultados, parámetros de programación y técnica quirúrgica de la ECP del Vim para el tratamiento del temblor. Resultados: Aunque los resultados clínicos son similares usando la talamotomía o la ECP del Vim, la primera causa más efectos adversos que la última. Además, la ECP puede ser usada bilateralmente, mientras que la talamotomía tiene un alto riesgo de causar disartria cuando se realiza de ambos lados. La ECP del Vim logró una adecuada mejoría del temblor en varias series de pacientes con temblor causado por temblor esencial, enfermedad de Parkinson o esclerosis múltiple. Además del Vim, hay otros blancos que están siendo usados por varios autores, tales como la zona incerta y las radiaciones prelemniscales. Conclusión: La ECP del Vim es un tratamiento útil para el temblor incapacitante refractario al tratamiento médico. Es esencial realizar una precisa selección de pacientes, así como utilizar una técnica quirúrgica correcta. Aún se desconoce el mejor blanco estereotáctico para el temblor, aunque el Vim es el más usado. PMID:25165613

  6. Gamma irradiation devices

    International Nuclear Information System (INIS)

    Foeldiak, Gabor; Stenger, Vilmos.

    1983-01-01

    The main parameters and the preparation procedures of the gamma radiation sources frequently applied for irradiation purposes are discussed. In addition to 60 Co and 137 Cs sources also the nuclear power plants offer further opportunities: spent fuel elements and products of certain (n,γ) reactions can serve as irradiation sources. Laboratory scale equipments, pilot plant facilities for batch or continuous operation, continuous industrial irradiators and special multipurpose, mobile and panorama type facilities are reviewed including those in Canada, USA, India, the Soviet Union, Hungary, UK, Japan and Australia. For irradiator design the source geometry dependence of the spatial distribution of dose rates can be calculated. (V.N.)

  7. Gamma rays for pedestrians

    International Nuclear Information System (INIS)

    Lipkin, H.J.

    1987-01-01

    Nuclear gamma radiation does not have many of the properties taken for granted in atomic or molecular radiation and necessary for lasers. The basic science and technology underlying these differences and the proposed methods of overcoming difficulties resulting from them are not properly understood. Considerable illumination in this interdisciplinary problem could be provided by some back-of-the-envelope calculations and simple experimental surveys by small groups of students and postdocs with an elementary knowledge of the nuclear and solid state physics which is evidently not familiar these days to laser physicists. 3 refs

  8. Gamma-scintigraphy

    International Nuclear Information System (INIS)

    Desgrez, H.A.

    1960-06-01

    Gamma-scintigraphy is a medical technique making it possible to fix the image of certain organs after the concentration in these of emitting radioactive products. It is already widely used in the case of the thyroid gland with iodine-132 by applying the isotope iodine 131. The study of the liver and gall bladder is carried out using colloidal gold 198 and Bengal pink marked with iodine 131. Serum albumin marked with iodine 131 makes it possible to study rachidian blockages. Other applications can already be foreseen in this direction. (author) [fr

  9. The gamma thermometer

    International Nuclear Information System (INIS)

    Beraud, G.; Hourtoulle, F.

    1983-01-01

    The search for a detecting element capable of permanently measuring localised nuclear output which would also be robust straightforward and reliable led EDF to begin development work on a new type of detector in 1976: the gamma thermometer (THG). After briefly summarising the history of the project this article goes on to describe the principle and structure of the equipment used in EDF's PWR reactors. As a result of the extensive test programme carried out it has been possible to qualify analytical and calibration methods together with the thermal and nuclear models. In conclusion, the development prospects and future of such a detecting device are outlined [fr

  10. Evaluation of Dose: Comparative Effect of Fast Neutrons and other Types of Radiation on the Survival of E. Coli and S. Cerevisiae; Evaluation de la Dose Delivree et Actions Comparees des Neutrons Rapides et d'Autres Radiations sur la Survie de E. Coli et S. Cerevisiae; Otsenka dozy i sravnitel'noe vliyanie bystrykh nejtronov i drugikh vidov izlucheniya na vyzhivaemost' E. Coli i S. Cerevisiae; Evaluacion de la Dosis Suministrada y Comparacion de la Accion de los Neutrones Rapidos sobre la Supervivencia del E. Coli y del S. Cerevisiae con la de Otras Radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Arnaud, Y.; Bocquet, C. [Centre d' Etudes Nucleaires de Saclay (France)

    1964-05-15

    The EL-3 reactor is equipped with auranium converter by means of which fast neutrons can be obtained. A bank of fission chambers measures the flux and spectral distribution of the fast neutrons. These miniature detectors are placed at various points in the target zone and make possible the experimental evaluation of the absorbed tissue-dose. This apparatus and dosimetric technique can be used to compare the effect of fast neutrons and other types of ionizing radiation (e.g. X-rays) on unicellular organisms. The authors study the percentage of survivals and the frequency of a mutation in Saccharomyces cerevisiae. The survival curve for Escherichia coli is also determined for X-rays and neutrons. It is found that the RBE's of these various types of radiation depend not only on the species and the biological criterion adopted, but also on the irradiation dose-level at which the comparison is made. These experiments show the RBE to be also a function of dose. The effects of fast neutrons and X-rays are often brought about by differing radiobiological processes. It is arbitrary to establish linear relationships between the doses for these various types of radiation. (author) [French] Nous disposons aupres du reacteur EL3 d'un convertisseur a uranium permettant d'obtenir des neutrons rapides. Une batterie de chambres a fission mesure le flux et la repartition spectrale des neutrons rapides. Ces detecteurs miniatures sont places en divers points du volume a irradier et permettent d'evaluer experimentalement la dose absorbee dans les tissus. Ce dispositif et cette dosimetrie nous servent a comparer l'action des neutrons rapides et d'autres radiations ionisantes (X, {gamma}) sur des organismes monocellulaires. Nous etudions ici le pourcentage de survie et la frequence d'une mutation morphologique chez Saccharomyces cerevisiae. La courbe de survie d'Escherichia coli est aussi etablie pour les rayons X et les neutrons. On observe que les effets biologiques relatifs de ces

  11. Doubly heavy baryon production at {gamma}{gamma} collider

    Energy Technology Data Exchange (ETDEWEB)

    Li Shiyuan [Department of Physics, Shandong University, Jinan 250100 (China)]. E-mail: lishy@sdu.edu.cn; Si Zongguo [Department of Physics, Shandong University, Jinan 250100 (China)]. E-mail: zgsi@sdu.edu.cn; Yang Zhongjuan [Department of Physics, Shandong University, Jinan 250100 (China)]. E-mail: yangzhongjuan@mail.sdu.edu.cn

    2007-05-10

    The inclusive production of doubly heavy baryons {xi}{sub cc} and {xi}{sub bb} at {gamma}{gamma} collider is investigated. It is found that the contribution from the heavy quark pair QQ in color triplet and color sextet are important.

  12. After-Ripening of Red Pepper (Capsicum Annuum) as Affected by Ionizing Radiation; Effets des Rayonnements Ionisants sur le Murissement du Piment (Capsicum Annuum) Apres la Recolte; Vliyanie ioniziruyushchego izlucheniya na dozrevanie krasnogo pertsa (Capsicum Annuum); Efecto de las Radiaciones Ionizantes en la Postmaturacion del Pimiento Rojo (Capsicum Annuum)

    Energy Technology Data Exchange (ETDEWEB)

    Farkas, J.; Kiss, I.; Andrassy, Eva [Central Food Research Institute, Budapest (Hungary)

    1966-11-15

    duree de la maturation apres la recolte et augmente la teneur en pigments. Il serait necessaire de poursuivre les recherches afin de determiner les conditions d'emmagasinage les plus favorables a La maturation du piment apres la recolte ainsi que les causes de la diminution de la teneur en carotenoiedes de fruits irradies au cours de la deuxieme moitie de la periode de stockage. (author) [Spanish] Se ha investigado el efecto directo de los rayos X, en dosis de 0 a 800 krad, sobre pimientos rojos dulces iecien recolectados, y sobre la postmaturacion de estos pimientos, en dosis de 0 a 100 krad. La irradiacion entre 400 y 800 krad causo el ablandamiento del pericarpo, pero el contenido de carotenoides no disminuyo apreciablemente incluso a dosis de 800 krad. Durante un periodo de almacenamiento de nueve semanas a la temperatura ambiente y despues de la irradiacion, se observo en las muestras no tratadas un aumento de un 90fy del contenido total de pigmentos, expresado en capsantina. La formacion de pigmentos carotenoides presento una ligera aceleracion para dosis de 80 rad y una fuerte aceleracion para dosis de 2 krad. Las muestras tratadas con 2 krad alcanzaron en tres semanas el mismo contenido de pigmentos que las muestras testigo en ocho semanas. En cambio, el contenido de pigmentos de las muestras irradiadas disminuyo al cabo de la cuarta o quinta semana de almacenamiento. Las dosis superiores a 10 krad frenaron o impidieron la formacion de carotenoides durante el almacenamiento (postmaturacion). La disminucion del contenido de.azucares y el ritmo de desecacion permanecieron invariables para dosis de 0 a 100 krad. Como las dosis de radiaciones (varios centenares de kilorad) necesarias para impedir o inhibir en medida apreciable el desarrollo de los mohos causantes de la deterioracion del pimiento rojo de gran contenido de agua tienen efectos perjudiciales, no parece aconsejable el empleo de las radiaciones para reducir las perdidas por almacenamiento en los pimientos

  13. Gamma ray beam transmutation

    International Nuclear Information System (INIS)

    Imasaki, K.; Li, D.; Miyamoto, S.; Amano, S.; Motizuki, T.

    2007-01-01

    We have proposed a new approach to nuclear transmutation by a gamma ray beam of Compton scattered laser photon. We obtained 20 MeV gamma ray in this way to obtain transmutation rates with the giant resonance of 1 97Au and 1 29Iodine. The rate of the transmutation agreed with the theoretical calculation. Experiments on energy spectrum of positron, electron and neutron from targets were performed for the energy balance and design of the system scheme. The reaction rate was about 1.5∼4% for appropriate photon energies and neutron production rate was up to 4% in the measurements. We had stored laser photon more than 5000 times in a small cavity which implied for a significant improvement of system efficiency. Using these technologies, we have designed an actual transmutation system for 1 29Iodine which has a 16 million year's activity. In my presentation, I will address the properties of this scheme, experiments results and transmutation system for iodine transmutation

  14. Asociación entre las radiaciones de teléfonos móviles y el riesgo tumoral en personas adultas

    Directory of Open Access Journals (Sweden)

    Patricia Bielsa-Fernández

    2018-01-01

    Conclusiones: Aunque la radiofrecuencia emitida por los teléfonos móviles tiene efectos tumorales sobre las personas, la evidencia científica disponible no es robusta. Son necesarios estudios más rigurosos, con mayores tamaños muestrales y periodos de seguimiento largos para conocer en profundidad los efectos a largo plazo.

  15. Thermoluminescent dependence with the particle size in ionized foods by radiation; Dependencia termoluminiscente con el tamano de particula en alimentos ionizados por radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Teuffer Z, C.A

    2005-07-01

    The influence of the particle size of poly minerals in the signals of the thermally stimulated luminescence (TL) is analysed. The poly minerals were extracted of Mexican spices such as Origanum vulgare L. (origanum) and Capsicum annum (Chilli guajillo), these underwent to an homogenization process to obtain four different particle sizes corresponding to 149, 74, 53 and 10 {mu} m, and later on to expose them to gamma radiation in an interval of 0.5- 45 kGy in the Gamma beam 651 PT of {sup 60} Co irradiator of the Nuclear Sciences Institute, UNAM. The glow curves show a maximum of TL intensity for Capsicum annum to dose of 0.5- 10 kGy with particle size selected by means of a mesh of opening of 53 {mu} m, while for Origanum vulgare L., the more intense emission is observed with 149 {mu} m. In the interval of dose 12- 45 kGy the maximum in intensity emission it was presented in 53 {mu} m in both cases. For the case of 10 {mu} m, the TL emissions were of smaller intensity, and were achieved glow curves in a clear, defined way and an overlapping that allows to center the maximum of TL emission, in a defined temperature 126 C for Origanum vulgare L., and 166 C for Capsicum annum. The behavior before described is related with the composition of the samples. For Capsicum annum it was found Quartz (60%), Albite (30%) and Ortosa (10%), while Origanum vulgare stops L., Quartz (50%), Calcite (20%), Albite (20%) and Clay (10%). The homogenization of the samples is an important factor because exists high probability of avoiding as much as possible rests of organic matter traces that can contribute to the total signal of the glow curves. Likewise the defects that pollute from a natural way to each one of the minerals found in the samples, they play an outstanding role in the TL emissions. Although to the interacting the gamma radiation with the poly minerals of different particle sizes, there is a certain energy transfer that will be translated in the absorbed dose and this it

  16. Evaluation of defects induced by neutron radiation in reactor pressure vessels steels; Evaluacion de los defectos inducidos por la radiacion neutronica en los aceros de vasijas

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Jimenez, J

    1978-07-01

    We have developed a method for calculating the production of neutron induced defects (depleted zone and crowdions) in ferritic pressure vessel steels for different neutron spectra. They have been analysed both the recoil primary atoms produced by elastic and inelastic collisions with fast neutrons and the ones produced by gamma-ray emission by thermal neutron absorption. Theoretical modelling of increasing in the ductile-brittle transition temperature of ferritic steels has been correlated with experimental data at irradiation temperature up to 400 degree centigree (Author) 15 refs.

  17. Observation of galactic gamma radiation

    International Nuclear Information System (INIS)

    Paul, J.A.

    1982-09-01

    A complete and deep survey of the galactic high-energy gamma radiation is now available, thanks to the gamma-ray telescopes on board of the SAS-2 and COS-B spacecrafts. A comparison of the COS-B gamma-ray survey with a fully sampled CO survey together with an Hsub(I) survey is used to show that a simple model, in which uniformly distributed cosmic rays interact with the interstellar gas, can account for almost all the gamma-ray emission observed in the first galactic quadrant. At medium galactic latitudes, it is shown that a relationship exists between the gamma radiation and the interstellar absorption derived from galaxy counts. Therefore gamma rays from the local galactic environment can be used as a valuable probe of the content and structure of the local interstellar medium. The large scale features of the local interstellar gas are revealed, in particular wide concentrations of nearby molecular hydrogen. On a smaller scale, the detection of numerous localized gamma-ray sources focuses the attention on some particular phases of clusters of young and massive stars where diffuse processes of gamma-ray emission may also be at work

  18. Gamma radiation in dwellings

    International Nuclear Information System (INIS)

    Mjoenes, L.

    1981-08-01

    A nationwide investigation has been made into the gamma radiation in Swedish dwellings. The measurements were made with small detectors containing thermoluminescent dosimeters. The detectors were sent to the selected participants by mail. 1300 dwellings were included in the investigation. In each dwelling three measurements were made: one detector was placed in the kitchen, one in the living-room and one in the bedroom. The mean annual absorbed tissue dose in dwellings in Sweden was found to be 0.65 mGy (corresponding to an exposition rate of 12 μR/h) when the contribution from cosmic radiation had been subtracted. That represents an annual collective dose of about 4000 mansieverts to the population of Sweden. From a previous investigation we have calculate the mean value for the gamma radiation in Swedish dwellings for 1950 to be 0.4 mGy/a (8μR/h). The reason for the relatively large increase in the mean value is an increased use of building materials on stone, particularly of lightweight concrete based on alum shale, from 1940 to middle 1960s. The production of this type of lightweight concrete was discontinued in 1975 and the use of other stone-based building materials has decreased. The mean value of gamma radiation in Swedish dwellings is therefore expected to decrease slowly in the future if this tendency holds. Sweden has some 3.5 million dwellings. About 10 % of them have mean values of 1 mGy/a (19 μR/h) or more, 0.2 % have 3 mGy/a (57 μR/h) or more and a couple of hundred 5 mGy/a (95 μR/h or more. The mean value for detached houses was found to be 0.43 mGy/a (8 μR/h) and for dwellings in multi-family houses 0.80 mGy/a (15 μR/h). The investigation dwellings have also been classified according to the building materials, the year of construction and the degree of urbanization of the area. (author)

  19. Cross-Linking of P.V.A. by Gamma Radiation; Reticulation de l'alcool polyvinylique par les rayons gamma; Dejstvie gamma-luchej na poperechnuyu svyaz' polivinologo spirta; Reticulacion del alcohol polivinilico por irradiacion gamma

    Energy Technology Data Exchange (ETDEWEB)

    Dieu, H; Desreux, V

    1960-07-15

    ,2-0,06%) il semble que le phenomene de reticulation intramoleculaire devienne de plus en plus important. En conclusion, les effets des rayonnements sur les solutions d'alcool polyvinylique seraient fonction de la concentration initiale de ces solutions. (author) [Spanish] Los autores estudiaron la accion de los rayos gamma sobre soluciones acuosas de alcohol polivinilico, determinando la viscosidad, constante de sedimentacion y grado de acetilacion del polimero. Existe una concentracion critica bien definida, a saber, 0,28 por ciento, por debajo de la cual es imposible obtener el gel B, sea cual fuere la dosis administrada. Por encima de esa concentracion, el fenomeno mas importante consiste al parecer en una reticulacion intermolecular cuyo grado aumenta en funcion de la dosis. Por debajo de la concentracion critica, los fenomenos son mucho mas complejos. Cuando las dosis son pequenas, es probable que los fenomenos de reticulacion inter e intramolecular compitan con la formacion de conglomerados moleculares de configuracion mas simetrica. A dosis mas elevadas, los agregados y los conglomerados moleculares experimentan una reticulacion interna y externa cada vez mas pronunciada, que conduce finalmente a la formacion de particulas de microgel. A medida que la concentracion disminuye (de 0,2 a 0,06 por ciento), el fenomeno de reticulacion intramolecular adquiere importancia creciente. En conclusion, puede admitirse que los efectos ejercidos por las radiaciones sobre las soluciones de alcohol polivinilico dependeran de la concentracion inicial de esas soluciones. (author) [Russian] Dejstvie gamma-luchej na vodnye rastvory polivinilovogo spirta soprovozhdalos' ustanovleniem vyazkosti, postoyannogo osazhdeniya i stepeni atsitilirovaiiya. Sushchestvuet tochno ustanovlennaya kriticheskaya kontsentratsiya v 0,28%, nizhe kotoroj nevozmozhno poluchit' obrazovanie massy V, kakova by ni byla doza. Esli kriticheskaya kontsentratsiya budet prevyshat' 0,28, to nablyudaetsya

  20. Gamma Ray Bursts - Observations

    Science.gov (United States)

    Gehrels, N.; Cannizzo, J. K.

    2010-01-01

    We are in an exciting period of discovery for gamma-ray bursts. The Swift observatory is detecting 100 bursts per year, providing arcsecond localizations and sensitive observations of the prompt and afterglow emission. The Fermi observatory is observing 250 bursts per year with its medium-energy GRB instrument and about 10 bursts per year with its high-energy LAT instrument. In addition, rapid-response telescopes on the ground are providing new capabilities to study optical emission during the prompt phase and spectral signatures of the host galaxies. The combined data set is enabling great advances in our understanding of GRBs including afterglow physics, short burst origin, and high energy emission.

  1. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1977-01-01

    A gamma camera system having control components operating in conjunction with a solid state detector is described. The detector is formed of a plurality of discrete components which are associated in geometrical or coordinate arrangement defining a detector matrix to derive coordinate signal outputs. These outputs are selectively filtered and summed to form coordinate channel signals and corresponding energy channel signals. A control feature of the invention regulates the noted summing and filtering performance to derive data acceptance signals which are addressed to further treating components. The latter components include coordinate and enery channel multiplexers as well as energy-responsive selective networks. A sequential control is provided for regulating the signal processing functions of the system to derive an overall imaging cycle

  2. Sterilization by gamma irradiation

    International Nuclear Information System (INIS)

    Reyes Frias, L.

    1992-01-01

    Since 1980 the National Institute of Nuclear Research counts with an Industrial Gamma Irradiator, for the sterilization of raw materials and finished products. Through several means has been promoted the use of this technology as alternative to conventional methods of sterilization as well as steam treatment and ethylene oxide. As a result of the made promotion this irradiator has come to its saturation limit being the sterilization irradiation one of the main services that National Institute of Nuclear Research offers to producer enterprises of disposable materials of medical use also of raw materials for the elaboration of cosmetic products and pharmaceuticals as well as dehydrated foods. It is presented the trend to the sterilization service by irradiation showed by the compilation data in a survey made by potential customers. (Author)

  3. Gamma radiolysis of dimethylglyoxime

    International Nuclear Information System (INIS)

    Langguth, H.; Foersterling, H.U.; Schmidt, J.

    1983-01-01

    Because dimethylglyoxime (DMG) is suitable for the selective separation of palladium from nuclear fuel reprocessing waste solutions the radiation resistance of pure DMG and of DMG sorbed on activated charcoal was studied. Irradiation was carried out at 20-40 0 C using a 60 Co gamma source with a dose rate of 0.6 - 1.7 Gy/s in the dose range 2 kGy to 5 MGy. The radiolytic products were determined by different methods and the G values determined. It has been shown that DMG is relatively radiation resistant up to doses of about 100 kGy. At higher doses the reactive NOH-groups of DMG are partially destroyed and cannot react with palladium. However, in the separation process of palladium from radioactive waste solutions these doses will not be reached so that complications due to insufficient radiation resistance of DMG can be excluded. (author)

  4. Gamma spectrometry on MANITU 271-01 gamma scan wires

    International Nuclear Information System (INIS)

    Dassel, G.; Buurveld, H.A.; Minkema, J.

    1994-08-01

    A series of irradiation experiments (271-series) is being performed of the sustain programme for material development and characterization of the NET (Next European Torus). In the framework of the first irradiation experiment 271-01, with irradiation up to 0.2 dpa, four gamma scan wires have been examined by gamma scanning. The purpose of the gamma scan wires (GSW) is to get information about the neutron fluence distribution in the capsules during irradiation. In the stainless steel wires the nuclides Co-58, Mu-54, Fe-59 and Co-60 are produced, are characteristic for fast and thermal neutron reactions. (orig./HP)

  5. Centro de Proteccion e Higiene de las Radiaciones (CPHR) Holguin Territorial Office Scientific Technical Co-operation in the field of ionizing radiation metrology: Results and perspectives

    International Nuclear Information System (INIS)

    Morales, J.A.; Bravo, R.

    1993-01-01

    This paper presents an overview of the activities carried out in order to organic a dosimetric calibration territorial service to be performed mainly with Secretaria Ejecutiva Para Asuntos Nucleares (SEAN) personnel and model facilities. This paper emphasizes the results of the calibration which will performed this service in joint association with CPHR specialist and Holguin Territorial Office (june 1993). The perspective of co-operation in this field starting up the CPHR dosimetric calibration secondary laboratory are presented

  6. Synthesis of Graft Copolymers by Small Doses of Irradiation; Synthese des copolymeres greffes au moyen de petites doses de rayonnements; Sintez privitykh sopolimerov s pomoshch'yu malykh doz oblucheniya; Sintesis de copolimeros de injerto mediante pequenas dosis de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Dobo, J; Somogyi, M; Kiss, L

    1960-07-15

    In addition to grafting, there is often an undesirable alteration in the properties of the original polymer when polymer monomer mixtures are irradiated. As a result of irradiation, grafting occurs not only on the original polymeric backbone, but also on the already grafted side-chains. The result is an acceleration of grafting. The effect is especially pronounced in the case of preformed polymers, if irradiation is carried out intermittently. The grafting of styrene can be accelerated by the addition of some solvents which suppress the protective effect of the styrene on the polymer. Grafting can be accelerated by other additives. The swelling properties of the irradiated films were investigated. (author) [French] Lorsque des melanges de polymeres et de monomeres sont soumis a des rayonnements, il se produit souvent, en meme temps que la greffe, une alteration facheuse des proprietes du polymere original. L'irradiation provoque une reaction de greffage, non seulement sur le polymere original, mais aussi sur les chaines laterales deja greffees. Il en resulte une acceleration du processus de greffage. L'effet est particulierement marque dans le cas des polymeres preformes, lorsque l'irradiation est effectuee par intermittence. On peut accelerer le processus de greffage du styrolene en ajoutant certains solvants qui suppriment l'action protectrice du styrolene sur le polymere. On peut aussi accelerer le processus a l'aide d'autres additifs. Les auteurs ont etudie les proprietes de gonflement des pellicules irradiees. (author) [Spanish] Simultaneamente con el injerto, bajo la accion de las radiaciones se produce frecuentemente una alteracion de las propiedades del polimero original, efecto que convendria evitar. Por lo tanto, quiza ofrezcan interes los elevados grados de injerto obtenidos en nuestros laboratorios con pequenas dosis de radiacion. La irradiacion no solo provoca una reaccion de injerto en la estructura polimerica original, sino tambien en las cadenas

  7. Interacciones de las radiaciones electromagnéticas y especies reactivas del oxígeno sobre la piel Interactions of electromagnetic radiations and reactive oxygen species on skin

    Directory of Open Access Journals (Sweden)

    A M Ferramola de Sancovich

    2006-06-01

    Full Text Available La energía radiante abarca todo el espectro electromagnético y proviene de la fusión en el sol, de 4 núcleos de hidrógeno en uno de helio. Las radiaciones electromagnéticas tienen características de ondas, con la velocidad de la luz (c y difieren en sus longitudes de ondas (λ. La energía lumínica es transmitida en unidades individuales o fotones: E = h c/λ así, los fotones de menores λs son los de mayor energía. Las radiaciones ultravioletas (UV (λs de 200 - 400 nm pueden dividirse: UVA (λs 315 - 400 nm; UVB (λs 280 - 315 nm y UVC (λs The energy of electromagnetic radiation is derived from the fusion in the sun of four hydrogen nuclei to form a helium nucleus. The sun radiates energy representing the entire electromagnetic spectrum. Light is a form of electromagnetic radiation. All electromagnetic radiation has wave characteristics and travels at the same speed (c: speed of light. But radiations differ in wavelength (λ. Light energy is transmitted not in a continuum stream but only in individual units or photons: E = h c/λ. Short wave light is more energetic than photons of light of longer wavelength. Ultraviolet radiations (UV (λs 200 - 400 nm can be classified in UVA (λs 315 - 400 nm.; UVB (λs 280 - 315 nm and UVC (λs < 280 nm. UVB and UVC are the most significant UV radiations to induce biological responses. Electromagnetic radiations on molecular oxygen lead to several reactive products known as Reactive Oxygen Species (ROS. High O2 content in biological systems promotes ROS synthesis. If ROS are not controlled by endogenous antioxidants, cell redox status is affected and tissue damage is produced ("oxidative stress". ROS induce lipid peroxidation, protein cross-linking, enzyme inhibition, loss of integrity and function of plasmatic and mitochondrial membranes conducing to inflammation, aging, carcinogenesis and cell death. While infra-red radiations lead to noticeable tissue temperature conducing to severe burns, UVA

  8. Economics of gamma irradiation processing

    International Nuclear Information System (INIS)

    Tani, Toshio

    1980-01-01

    The gamma-ray irradiation business started at the Takasaki Laboratory of Japan Atomic Energy Research Institute. The irradiation facilities were constructed thereafter at various sites. The facilities must accept various types of irradiation, and must be constructed as multi-purpose facilities. The cost of irradiation consists of the cost of gamma sources, construction expense, personnel expense, management expense, and bank interest. Most of the expenses are considered to be fixed expense, and the amount of irradiation treatment decides the original costs of work. The relation between the irradiation dose and the construction expense shows the larger facility is more economical. The increase of amount of treatment reduces the original cost. The utilization efficiency becomes important when the amount of treatment and the source intensity exceed some values. The principal subjects of gamma-ray irradiation business are the sterilization of medical tools and foods for aseptic animals, the improvement of quality of plastic goods, and the irradiation of foods. Among them, the most important subject is the sterilization of medical tools. The cost of gamma irradiation per m 3 in still more expensive than that by ethylene oxide gas sterilization. However, the demand of gamma-ray irradiation is increasing. For the improvement of quality of plastic goods, electron irradiation is more favourable than the gamma irradiation. In near future, the economical balance of gamma irradiation can be achieved. (Kato, T.)

  9. Apparatus for gamma ray radiography

    International Nuclear Information System (INIS)

    Kobayashi, Masatoshi; Enomoto, Shigemasa; Oga, Hiroshi

    1979-01-01

    This is the standard of Japan Non-Destructive Inspection Society, NDIS 1101-79, which stipulates on the design, construction and testing method of the apparatuses for gamma ray radiography used for taking industrial radiograms. The gamma ray apparatuses stipulated in this standard are those containing sealed radioactive isotopes exceeding 100 μCi, which emit gamma ray. The gamma ray apparatuses are classified into three groups according to their movability. The general design conditions, the irradiation dose rate and the sealed radiation sources for the gamma ray apparatuses are stipulated. The construction of the gamma ray apparatuses must be in accordance with the notification No. 52 of the Ministry of Labor, and safety devices and collimators must be equipped. The main bodies of the gamma ray apparatuses must pass the vibration test, penetration test, impact test and shielding efficiency test. The method of each test is described. The attached equipments must be also tested. The tests according to this standard are carried out by the makers of the apparatuses. The test records must be made when the apparatuses have passed the tests, and the test certificates are attached. The limit of guarantee by the endurance test must be clearly shown. The items to be shown on the apparatuses are stipulated. (Kako, I.)

  10. Best practices for ink jet decoration lines in ceramics. Electromagnetic radiation IR machine (wavelength technology); Mejoras practicas para lineas de decoracion Inkjet en ceramica. Maquina IR de radiaciones electromagneticas (tecnologia de longitud de onda)

    Energy Technology Data Exchange (ETDEWEB)

    Galvez, J; Galvez, D

    2012-07-01

    SACMI IBERICA, S.A., has been awarded by the Spanish Society of Ceramics and Glass (SECV), with one GOLD ALFA, in its 2012 edition, during CEVISAMA for the presentation of the innovative IR Electromagnetic Radiation Machine, which improves the conditions and the production performance of digital decoration lines INKJET and other decorative applications ceramic tile. (Author)

  11. Analysis of solar radiation and other variables for the evaluation of locations of thermo solar power stations; Analisis de radiacion solar y otras vairables para la evaluacion de emplazamientos de centrales termosolares

    Energy Technology Data Exchange (ETDEWEB)

    Montero, I.; Miranda, M. T.; Rojas, S.; Bolinaga, B.; Tierra, C.; Pico, J. del

    2008-07-01

    This paper presents the characteristics of various measuring weather stations located in future CCP thermal plants, showing the different systems they are equipped with, among others, pyrheliometer, pyrano meter, anemometers, thermo-hygrometer and data transmission system. Some results of solar radiation and other climate variables obtained in these stations are presented and analyzed in relation to existing data in the area, taking into account different external parameters that can influence the direct radiation obtained and, therefore, the future operation of the thermal plant. (Author)

  12. Generation of global hourly radiation sequences using a Transition Markov matrix for Madrid. Generacion de secuencias horarias de radiacion global utilizando matrices de transicion de Markov, para la localidad de Madrid

    Energy Technology Data Exchange (ETDEWEB)

    Mora, Ll

    1989-11-01

    The aim of this work is the generation of sequences of hourly global radiation which have similar statistically characteristics of real sequences for the city of Madrid (Spain). For this generation, a first order Markov model has been proposed. The input parameters of simulation method are the following: The maximum value of hourly radiation and the average monthly value of the transparency normalized index. The maximum value of hourly radiation has been calculated as a function of the solar height by an empirical expression. The transparency normalized index has been defined as the ratio among the measured hourly global radiation to the maximum value for the corresponding solar height. The method is based on the following observations: -The transparency normalized index shows a significant correlation only for two consecutive hours. -The months with the same average transparency normalized indies have similar probability density function. Global solar radiation, time series, simulation, Markov transition matrix, solar energy.

  13. Use of ultrasound radiation for extraction of bioactive compounds from natural sources. Current events and perspectives; Empleo de la radiacion ultrasonica para la extraccion de compuestos bioactivos provenientes de fuentes naturales. Estado actual y perspectivas

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Riera, Zalua [Instituto Superior de Tecnologia y Ciencias Aplicadas (INSTEC), La Habana (Cuba); Robaina Mesa, Malvis [Centro de Investigacion y Desarrollo de Medicamentos, La Habana (Cuba); Jauregui Haza, Ulises, E-mail: zalua@instec.cu [Instituto Superior de Tecnologia y Ciencias Aplicadas (INSTEC), La Habana (Cuba)

    2014-07-01

    In recent years, clean technologies have been developed for high efficiency extracting of isolation of biologically active compounds from natural sources, without the loss of biological activity, with good yield and high purity. Ultrasound-assisted extraction has low instrumental requirements and their implementation is very appropriate where the stability of the active component to be removed is affected by the high temperatures of conventional processes. In this paper it is evaluated the state of the art of ultrasound-assisted extraction of bioactive compounds from various natural sources, its mechanism, the parameters governing its use and research perspectives in this field. Ultrasonic cavitation phenomenon promotes cell wall rupture, reduction of particle size and tissue permeability, which facilitates the diffusion of the solvent into the inert part of the plant material and increasing the mass transferred through membranes. This mechanism explains the high efficiency of ultrasound-assisted extraction as it allows to reduce the time, temperature and amounts of solvent extraction process with high yields and high purity of the extracted product. Currently there is a great demand for the use of ultrasound to industrial and current research lead to the development of larger scale reactors and the theoretical modeling of the parameters that determine efficient extraction.

  14. Design and implementation of a software for the remote control and monitoring of radiation portals; Diseno e implementacion de un software para la gestion y monitorizacion remota de porticos de radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Miranda, J.; Rica, P. de la; Vivas, A.; Caballero, M.; Baeza, A.

    2012-07-01

    This paper describes the main activities developed for the detection of ionizing radiation in each eco-park access and have knowledge in time of the radioactive contents which possess the containers to the entry of these facilities, to identify both locally and remotely the origin of radiological anomalies that occur and act accordingly to correct them.

  15. Didactic revision of the operative magnitudes system ICRU for the evaluation of the equivalent dose in radiation external fields; Revision didactica del sistema de magnitudes operativas ICRU para la evaluacion de la dosis equivalente en campos externos de radiacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J. T., E-mail: trinidad.alvarez@inin.gob.mx [ININ, Departamento de Metrologia de Radiaciones Ionizantes, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2014-10-15

    In this work is presented in a didactic way the operative magnitudes system ICRU, showing as these magnitudes carry out an appropriate estimate of the effective equivalent doses H{sub E} and the effective dose. The objective is to present the basic concepts of the dosimetry for radiation external fields with purposes of radiological protection, because the assimilation lack and technological development of this dosimetric magnitudes system has persisted for near 50 years, in terms of practice of the radiological protection in Mexico. Also, this system is an essential part of safety basic standards of the IAEA and ICRP recommendations 26, 60, 74 and 103, as well as of the ICRU 25, 39, 43, 51 and 57. (Author)

  16. Intercomparison of dispersed radiation readings among film dosimetry, electronic and OSL with X-rays for low dose; Intercomparacion de lecturas de radiacion dispersa entre dosimetria film, electronica y OSL con rayos X para dosis bajas

    Energy Technology Data Exchange (ETDEWEB)

    Andisco, D. [Universidad de Buenos Aires, Facultad de Medicina, Paraguay 2155, C1121AAA Buenos Aires (Argentina); Blanco, S. [CONICET, Saavedra 15, C1083ACA Buenos Aires (Argentina); Bourel, V.; Schmidt, L. [Universidad Favaloro, Facultad de Ciencias e Ingenieria, Solis 453, C1078AAI, Buenos Aires (Argentina); Di Risio, C., E-mail: dandisco@fmed.uba.ar [Universidad de Belgrano, Facultad de Ingenieria, Zabala 1837, C1426DQG, Buenos Aires (Argentina)

    2014-08-15

    One of the personal dosimetry methods more used for several decades is the dosimetry type film, characterized to possess readings with certain margin of trust. Today other methods exist that many times are presupposed more reliable due to the nature of the detection like the electronic dosimeters or the OSL (Optically Stimulated Luminescence) dosimetry. With the purpose of comparing different methods and to can determining the existent differences among each method has been carried out an intercomparison assay. The different dosimeters have been exposed to dispersed radiation generated by a Hemodynamics equipment of the type -arch in C- and a dispersing system of the primary beam. Film dosimeters have been used; OSL (In Light), OSL (Nano Dots) and Electronic with the purpose of knowing and to valorize the existent differences among its readings. Always, the intercomparison exercises have demonstrated to be an useful tool when establishing the measurement capacity and the quality of the results emitted by the laboratories of personal dosimetry services. Also, this type of assays allows obtaining quality indicators of the laboratory performance and they are habitual part of the procedures for accreditation of the same ones. The Optically Stimulated Luminescence is a technology that has grown in Argentina so much in the area of personal dosimetry as in dosimetry in vivo (radiotherapy area). In this intercomparison study, the answers corresponding to each technology were looked for oneself irradiation of the disperse type, that is to say, of very low energy. (Author)

  17. Radiative decay of the eta-, eta'-mesons in the nonlocal quark model. [eta(eta'). --> gamma gamma. ; eta. -->. pi. /sup +/. pi. /sup -/. gamma. ; eta. -->. pi. /sup 0/2. gamma. ; eta'. -->. rho/sup 0/. gamma. ; eta'. -->. omega gamma. ;. pi. /sup 0/. -->. gamma. e/sup +/e/sup -/; eta(eta'). -->. gamma mu. /sup +/. mu. /sup -/

    Energy Technology Data Exchange (ETDEWEB)

    Efimov, G V; Ivanov, M A; Nogovitsyn, E A [Joint Inst. for Nuclear Research, Dubna (USSR)

    1981-07-01

    P..--> gamma gamma.. (P=..pi../sup 0/, eta, eta'), eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta/sup 1/..-->..V..gamma.. (V=rho/sup 0/, ..omega..), p..--> gamma..l/sup +/l/sup -/ (p=..pi../sup 0/, eta, eta') radiation decays are studied for testing the applicability of the non-local quark model for description of the experimental data. The Feynman diagrams of these decays are presented, values of the widths of the Veta..--> gamma gamma.., eta..--> pi../sup +/..pi../sup -/..gamma.., eta..--> pi../sup 0/..gamma gamma.., eta'..--> gamma gamma.., eta'..-->..rho/sup 0/..gamma.., eta'..--> omega gamma.. decays are calculated and given in the form of a table. Calculations are carried out for two values of the eta eta'-crossing angle: THETA=-11 deg and -18 deg. Values of invariant amplitudes of these decays are determined for ..pi../sup 0/..--> gamma..e/sup +/e/sup -/, eta..--> gamma mu../sup +/..mu../sup -/, eta'..--> gamma mu../sup +/..mu../sup -/ decays at THETA=-11 deg and -18 deg. The best agreement with the experimental data is noted to take place at THETA=-11 deg, the determined width of the eta..--> pi../sup 0/..gamma gamma.. decays is underestimated as compared with the experimental one.

  18. Total Cross Section in $\\gamma\\gamma$ Collisions at LEP

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Ewers, A.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kafer, D.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofiev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Roth, Stefan; Rosenbleck, C.; Roux, B.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Teyssier, D.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, A.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2001-01-01

    The reaction e+e- -> e+e- gamma* gamma* -> e+e- hadrons for quasi-real photons is studied using data from root(s) = 183 GeV up to 202 GeV. Results on the total cross sections sigma(e+e- -> e+e- hadrons) and sigma(+e- gamma* gamma* -> e+e- hadrons) are given for the two-photon centre-of-mass energies 5 GeV < Wgammagamma < 185 GeV. The total cross section of two real photons is described by a Regge parametrisation. We observe a steeper rise with the two-photon centre-of-mass energy as compared to the hadron-hadron and the photon-proton cross sections. The data are also compared to the expectations of different theoretical models.

  19. The gamma contamination food factor

    International Nuclear Information System (INIS)

    Kukoc, A.H.; Anicin, I.V.; Adzic, P.R.

    1992-01-01

    We suggest that radioactive food contamination, as determined solely by a quantitative gamma-ray spectroscopic measurement, may, apart from the total activity per unit mass, be for quick reference conveniently characterized by another single figure which we call the ''Gamma Contamination Food Factor'' (GCFF). This factor may be defined as the ratio of the total specific activity of gamma-ray-emitting radionuclides in the food sample (except that of 40 K) to the specific activity of 40 K either in the sample itself or in an ''average man''. We discuss briefly the meaning and advantages of these definitions. (author)

  20. Advanced HEDL gamma scan system

    International Nuclear Information System (INIS)

    Smith, F.C.; Olson, R.N.

    1983-01-01

    The design of an advanced state-of-the-art gamma scan system built for the purpose of measuring the point-by-point gamma activity of irradiated fuel rods is described. The emphasis of the system design was to achieve the highest rate of throughput with the minimum per rod cost while maintaining system accuracy and reliability. Preliminary tests demonstrate that all system requirements were met or exceeded. The system provides improved throughput, precision, automation, flexibility, and data processing capability over previous gamma scan systems

  1. Gamma-gamma angular correlation measurement in the 100 Ru

    International Nuclear Information System (INIS)

    Kenchian, G.

    1990-01-01

    An angular correlation automatic spectrometer with two Ge(Li) detectors has been developed. The spectrometer moves automatically, controlled by a microcomputer. The gamma-gamma directional angular correlations of coincidence transitions have been measured in 100 Ru nuclide, following the β + and electron capture of 100 Rh. The 100 Rh source has been produced with 100 Ru(p,n) 100 Rh reaction, using the proton beam of the Cyclotron Accelerator insiding in 100 Ru isotope. (author)

  2. Gamma spectrometry of 285-04 ILAS gamma scan wires

    International Nuclear Information System (INIS)

    Dassel, G.; Buurveld, H.A.; Plakman, J.C.

    1996-12-01

    In the frame work of their on-going sustain programme for the material development and characterization of fusion reactors, ECN is investigating the irradiation behaviour of ferritic/martensitic steels. In the fourth irradiation experiment 285-04, 55 steel tensile samples have been irradiated up to 2.5 dpa. Four gamma scan wires from this experiment have been examined by gamma scanning. The results of the measurements have been described in this report. (orig.)

  3. Gamma spectrometry of 285-03 ILAS gamma scan wires

    International Nuclear Information System (INIS)

    Dassel, G.; Buurveld, H.A.; Plakman, J.C.

    1996-12-01

    In the frame work of their on-going sustain programme for the material development and characterization of fusion reactors, ECN is investigating the irradiation behaviour of ferritic/martensitic steels. In the third irradiation experiment 285-03, 55 vanadium (V-4Cr-4Ti) tensile samples have been irradiated up to 6 dpa. Four gamma scan wires from this experiment have been examined by gamma scanning. The results of the measurements have been described in this report. (orig.)

  4. $\\gamma$-$\\gamma$ and $\\gamma$-p events at high energies

    CERN Document Server

    Schuler, Gerhard A.; Gerhard A Schuler; Torbjorn Sjostrand

    1994-01-01

    A real photon has a complicated nature, whereby it may remain unresolved or fluctuate into a vector meson or a perturbative q-qbar pair. Based on this picture, we previously presented a model for gamma-p events that is based on the presence of three main event classes: direct, VMD and anomalous. In gamma-gamma events, a natural generalization gives three-by-three combinations of the nature of the two incoming photons, and thus six distinct event classes. The properties of these classes are constrained by the choices already made, in the gamma-p model, of cut-off procedures and other aspects. It is therefore possible to predict the energy-dependence of the cross section for each of the six components separately. The total cross section thus obtained is in good agreement with data, and also gives support to the idea that a simple factorized ansatz with a pomeron and a reggeon term can be a good approximation. Event properties undergo a logical evolution from p-p to gamma-p to gamma-gamma events, with larger cha...

  5. Effects of Gamma Radiation on the Constituents of Wheat Flour; Action des Rayons Gamma sur les Elements Constitutifs de la Farine de Ble; Dejstvie gamma-luchej na sostavnye ehlementy muki; Accion de los Ratos Gamma Sobre los Elementos Constitutivos de la Harina de Trigo

    Energy Technology Data Exchange (ETDEWEB)

    Deschreider, A. R. [Laboratoire Central du Ministere des Affaires Economiques, Bruxelles (Belgium)

    1966-11-15

    constituent. On a releve que de faibles doses de rayons gamma, 20 000 a 150 000 rad, font apparaitre un maximum dans les courbes: de viscosite de l'amidon, des substances precipitables par electrodialyse, de la solubilite des gliadines et de l'indice Hagberg. Cette anomalie explique l'amelioration des qualites boulangeres que certains auteurs ont enregistree pour des farines irradiees avec de faibles doses de rayonnement gamma. (author) [Spanish] Los elementos constitutivos de la harina irradiada con rayos gamma presentan alteraciones fisicas, quimicas y bioquimicas. Estas alteraciones dependen del origen de la harina y son mas importantes cuanto mas elevada es la dosis de irradiacion. Los carotinoides de la fraccion oleosa de la harina disminuyen bajo la accion de las radiaciones y desaparecen cuando la dosis alcanza 4 Mrad. En los lipidos se producen reacciones analogas a las que engendran los hidroperoxidos, pero su composicion quimica permanece practicamente invariable, incluso cuando las dosis son muy elevadas. La importante degradacion del almidon indica que los polisacaridos de la harina son las fracciones mas fuertemente afectadas por las radiaciones. Esto da lugar a un aumento de las sustancias reductores preexistentes y del indice de maltosa, paralelo a la elevacion de las dosis aplicadas. Pero el incremento de la produccion autolitica de los azucares reductores en la harina irradiada se debe a una mayor sensibilidad del almidon a la hidrolisis por las diastasas. La desnaturalizacion de los polisacaridos provoca perdida de viscosidad en los engrudos de almidon, debida al aumento de solubilidad de la amilopectina. En general, la irradiacion gamma reduce la actividad proteolitica de la harina y, en dosis elevadas, provoca no solo una desnaturalizacion parcial de las proteinas, sino tambien su polimerizacion y/o condensacion. Esta polimerizacion puede explicarse por la reaccion de radicales libres con las proteinas del gluten que poseen grupos -SH, y por la reaccion de

  6. Fuzzy logic application for data correction of gamma ray profile and correlation with effective porosity of core from Resende Basin, Rio de Janeiro; Aplicacao da logica fuzzy para correcao de dados de perfil de raios gama e correlacao com porosidade efetiva de testemunhos da Bacia de Resende, Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Souza, Francisco de Assis Leal de; Tunala, Leonardo Fernandes; Abreu, Carlos Jorge de; Lopes, Ricardo Tadeu, E-mail: pachoteki@yahoo.com.br, E-mail: leotunala@hotmail.com, E-mail: abreu@geologia.ufrj.br, E-mail: ricardo@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ/CCMN), RJ (Brazil). Centro de Ciencias Matematicas e da Natureza. Inst. de Geociencias. Dept. de Geologia; Rocha, Paula Lucia Ferrucio da, E-mail: ferrucio@acd.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Martins, Ricardo Rhomberg, E-mail: ricardo301@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola Politenica de Engenharia; Lima, Inaya Correa Barbosa, E-mail: inaya@lin.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Centro de Tecnologia

    2010-12-15

    This work presents here a study on the porosity of cores from Resende Basin (Rio de Janeiro). The first step involved the selection, thinning of the material (core) and sample preparation for the use of porosimeter to obtain effective porosity. The material studied is sandstone, friable, coarse to very fine of three wells (GPR1, GPR2 and GPR3). The fuzzy logic (MatLab) was applied to the effective porosity data calculated from the gamma ray (GR) profile for the construction of a synthetic profile and from this we could identify the errors made in calculating the data. Then the results of porosity from the core were correlated with data from the corrected effective porosity (gamma ray profile) in order to prove the results obtained with both methods. The analysis of the synthetic porosity calculated by the fuzzy logic has shown that this is a promising method for assessing the quality of data and to obtain good fits. (author)

  7. On the possible effects of gluon number fluctuations on {gamma}{gamma} collisions at high energies

    Energy Technology Data Exchange (ETDEWEB)

    Goncalves, V. P.; De Santana Amaral, J. T. [Instituto de Fisica e Matematica, Universidade Federal de Pelotas, Caixa Postal 354, 96010-900, Pelotas, RS (Brazil)

    2013-03-25

    We investigate the effects of the fluctuations on the total {gamma}{gamma}, {gamma}*{gamma}* cross sections and the real photon structure function F{sup {gamma}}{sub 2}(x,Q{sup 2}), considering a saturation phenomenological model for the dipole-dipole cross section and scattering amplitude with fluctuations included.

  8. Programa para la atención medica integral a niños expuestos a contaminación ambiental por sustancias radiactivas

    Directory of Open Access Journals (Sweden)

    Carlos Dotres Martínez

    1995-04-01

    Full Text Available Se elaboró un programa de atención médica integral masiva a niños procedentes de zonas afectadas por contaminación ambiental. Este incluyó, la selección de los niños, su clasificación según el grado de afectación, los niveles de atención médica brindada de acuerdo con la experiencia cubana del médico de la familia y el Programa Materno-Infantil, así como los objetivos que perseguía. Dicho programa contempló también la medición de radiaciones y estimación de pronósticos, chequeo clínico y de laboratorio general y especializado según los casos, acciones psicológicas para la limitación del daño de la salud mental, así como la atención estomatológica. Se estableció un subsistema novedoso y multidisciplinario de organización de atención médica integral, el cual se basó en la experiencia del Sistema Nacional de Salud de Cuba.

  9. Study of the $e^+ e^- \\to Z\\gamma\\gamma \\to q\\overline{q}\\gamma\\gamma$ Process at LEP

    CERN Document Server

    Acciarri, M.; Adriani, O.; Aguilar-Benitez, M.; Alcaraz, J.; Alemanni, G.; Allaby, J.; Aloisio, A.; Alviggi, M.G.; Ambrosi, G.; Anderhub, H.; Andreev, Valery P.; Angelescu, T.; Anselmo, F.; Arefev, A.; Azemoon, T.; Aziz, T.; Bagnaia, P.; Bajo, A.; Baksay, L.; Balandras, A.; Baldew, S.V.; Banerjee, S.; Banerjee, Sw.; Barczyk, A.; Barillere, R.; Bartalini, P.; Basile, M.; Batalova, N.; Battiston, R.; Bay, A.; Becattini, F.; Becker, U.; Behner, F.; Bellucci, L.; Berbeco, R.; Berdugo, J.; Berges, P.; Bertucci, B.; Betev, B.L.; Bhattacharya, S.; Biasini, M.; Biglietti, M.; Biland, A.; Blaising, J.J.; Blyth, S.C.; Bobbink, G.J.; Bohm, A.; Boldizsar, L.; Borgia, B.; Bourilkov, D.; Bourquin, M.; Braccini, S.; Branson, J.G.; Brochu, F.; Buffini, A.; Buijs, A.; Burger, J.D.; Burger, W.J.; Cai, X.D.; Capell, M.; Cara Romeo, G.; Carlino, G.; Cartacci, A.M.; Casaus, J.; Castellini, G.; Cavallari, F.; Cavallo, N.; Cecchi, C.; Cerrada, M.; Cesaroni, F.; Chamizo, M.; Chang, Y.H.; Chaturvedi, U.K.; Chemarin, M.; Chen, A.; Chen, G.; Chen, G.M.; Chen, H.F.; Chen, H.S.; Chiefari, G.; Cifarelli, L.; Cindolo, F.; Civinini, C.; Clare, I.; Clare, R.; Coignet, G.; Colino, N.; Costantini, S.; Cotorobai, F.; de la Cruz, B.; Csilling, A.; Cucciarelli, S.; Dai, T.S.; van Dalen, J.A.; D'Alessandro, R.; de Asmundis, R.; Deglon, P.; Degre, A.; Deiters, K.; della Volpe, D.; Delmeire, E.; Denes, P.; DeNotaristefani, F.; De Salvo, A.; Diemoz, M.; Dierckxsens, M.; van Dierendonck, D.; Dionisi, C.; Dittmar, M.; Dominguez, A.; Doria, A.; Dova, M.T.; Duchesneau, D.; Dufournaud, D.; Duinker, P.; El Mamouni, H.; Engler, A.; Eppling, F.J.; Erne, F.C.; Ewers, A.; Extermann, P.; Fabre, M.; Falagan, M.A.; Falciano, S.; Favara, A.; Fay, J.; Fedin, O.; Felcini, M.; Ferguson, T.; Fesefeldt, H.; Fiandrini, E.; Field, J.H.; Filthaut, F.; Fisher, P.H.; Fisk, I.; Forconi, G.; Freudenreich, K.; Furetta, C.; Galaktionov, Iouri; Ganguli, S.N.; Garcia-Abia, Pablo; Gataullin, M.; Gau, S.S.; Gentile, S.; Gheordanescu, N.; Giagu, S.; Gong, Z.F.; Grenier, Gerald Jean; Grimm, O.; Gruenewald, M.W.; Guida, M.; van Gulik, R.; Gupta, V.K.; Gurtu, A.; Gutay, L.J.; Haas, D.; Hasan, A.; Hatzifotiadou, D.; Hebbeker, T.; Herve, Alain; Hidas, P.; Hirschfelder, J.; Hofer, H.; Holzner, G.; Hoorani, H.; Hou, S.R.; Hu, Y.; Iashvili, I.; Jin, B.N.; Jones, Lawrence W.; de Jong, P.; Josa-Mutuberria, I.; Khan, R.A.; Kafer, D.; Kaur, M.; Kienzle-Focacci, M.N.; Kim, D.; Kim, J.K.; Kirkby, Jasper; Kiss, D.; Kittel, W.; Klimentov, A.; Konig, A.C.; Kopal, M.; Kopp, A.; Koutsenko, V.; Kraber, M.; Kraemer, R.W.; Krenz, W.; Kruger, A.; Kunin, A.; Ladron de Guevara, P.; Laktineh, I.; Landi, G.; Lebeau, M.; Lebedev, A.; Lebrun, P.; Lecomte, P.; Lecoq, P.; Le Coultre, P.; Lee, H.J.; Le Goff, J.M.; Leiste, R.; Levtchenko, P.; Li, C.; Likhoded, S.; Lin, C.H.; Lin, W.T.; Linde, F.L.; Lista, L.; Liu, Z.A.; Lohmann, W.; Longo, E.; Lu, Y.S.; Lubelsmeyer, K.; Luci, C.; Luckey, David; Lugnier, L.; Luminari, L.; Lustermann, W.; Ma, W.G.; Maity, M.; Malgeri, L.; Malinin, A.; Mana, C.; Mangeol, D.; Mans, J.; Marian, G.; Martin, J.P.; Marzano, F.; Mazumdar, K.; McNeil, R.R.; Mele, S.; Merola, L.; Meschini, M.; Metzger, W.J.; von der Mey, M.; Mihul, A.; Milcent, H.; Mirabelli, G.; Mnich, J.; Mohanty, G.B.; Moulik, T.; Muanza, G.S.; Muijs, A.J.M.; Musicar, B.; Musy, M.; Napolitano, M.; Nessi-Tedaldi, F.; Newman, H.; Niessen, T.; Nisati, A.; Kluge, Hannelies; Ofierzynski, R.; Organtini, G.; Oulianov, A.; Palomares, C.; Pandoulas, D.; Paoletti, S.; Paolucci, P.; Paramatti, R.; Park, H.K.; Park, I.H.; Passaleva, G.; Patricelli, S.; Paul, Thomas Cantzon; Pauluzzi, M.; Paus, C.; Pauss, F.; Pedace, M.; Pensotti, S.; Perret-Gallix, D.; Petersen, B.; Piccolo, D.; Pierella, F.; Pieri, M.; Piroue, P.A.; Pistolesi, E.; Plyaskin, V.; Pohl, M.; Pojidaev, V.; Postema, H.; Pothier, J.; Prokofev, D.O.; Prokofiev, D.; Quartieri, J.; Rahal-Callot, G.; Rahaman, M.A.; Raics, P.; Raja, N.; Ramelli, R.; Rancoita, P.G.; Ranieri, R.; Raspereza, A.; Raven, G.; Razis, P.; Ren, D.; Rescigno, M.; Reucroft, S.; Riemann, S.; Riles, Keith; Rodin, J.; Roe, B.P.; Romero, L.; Rosca, A.; Rosier-Lees, S.; Roth, Stefan; Rosenbleck, C.; Roux, B.; Rubio, J.A.; Ruggiero, G.; Rykaczewski, H.; Saremi, S.; Sarkar, S.; Salicio, J.; Sanchez, E.; Sanders, M.P.; Schafer, C.; Schegelsky, V.; Schmidt-Kaerst, S.; Schmitz, D.; Schopper, H.; Schotanus, D.J.; Schwering, G.; Sciacca, C.; Seganti, A.; Servoli, L.; Shevchenko, S.; Shivarov, N.; Shoutko, V.; Shumilov, E.; Shvorob, A.; Siedenburg, T.; Son, D.; Smith, B.; Spillantini, P.; Steuer, M.; Stickland, D.P.; Stone, A.; Stoyanov, B.; Straessner, A.; Sudhakar, K.; Sultanov, G.; Sun, L.Z.; Sushkov, S.; Suter, H.; Swain, J.D.; Szillasi, Z.; Sztaricskai, T.; Tang, X.W.; Tauscher, L.; Taylor, L.; Tellili, B.; Teyssier, D.; Timmermans, Charles; Ting, Samuel C.C.; Ting, S.M.; Tonwar, S.C.; Toth, J.; Tully, C.; Tung, K.L.; Uchida, Y.; Ulbricht, J.; Valente, E.; Vesztergombi, G.; Vetlitsky, I.; Vicinanza, D.; Viertel, G.; Villa, S.; Vivargent, M.; Vlachos, S.; Vodopianov, I.; Vogel, H.; Vogt, H.; Vorobev, I.; Vorobov, A.A.; Vorvolakos, A.; Wadhwa, M.; Wallraff, W.; Wang, M.; Wang, X.L.; Wang, Z.M.; Weber, A.; Weber, M.; Wienemann, P.; Wilkens, H.; Wu, S.X.; Wynhoff, S.; Xia, L.; Xu, Z.Z.; Yamamoto, J.; Yang, B.Z.; Yang, C.G.; Yang, H.J.; Yang, M.; Ye, J.B.; Yeh, S.C.; Zalite, A.; Zalite, Yu.; Zhang, Z.P.; Zhu, G.Y.; Zhu, R.Y.; Zichichi, A.; Zilizi, G.; Zimmermann, B.; Zoller, M.

    2001-01-01

    The process e^+e^- -> Z gamma gamma -> q q~ gamma gamma$ is studied in 0.5\\,fb-1$ of data collected with the L3 detector at centre-of-mass energies between 130.1 GeV and 201.7 GeV. Cross sections are measured and found to be consistent with the Standard Model expectations. The study of the least energetic photon constrains the quartic gauge boson couplings to -0.008 GeV-2 < a_0/\\Lambda^2 < 0.005 GeV-2 and -0.007 GeV-2 < a_c/\\Lambda^2 < 0.011 GeV-2, at 95% confidence level.

  10. The Winfrith district gamma survey

    International Nuclear Information System (INIS)

    Cavell, I.W.; Peabody, C.O.

    1961-09-01

    This report describes the District Gamma Survey carried out around the A.E.E., Winfrith since June, 1959. Its organisation, equipment and techniques are described, and the results obtained up to the 31st December, 1960 are given. (author)

  11. Gamma rays at airplane altitudes

    International Nuclear Information System (INIS)

    Iwai, J.; Koss, T.; Lord, J.; Strausz, S.; Wilkes, J.; Woosley, J.

    1990-01-01

    An examination of the gamma ray flux above 1 TeV in the atmosphere is needed to better understand the anomalous showers from point sources. Suggestions are made for future experiments on board airplanes

  12. Application of Radiation for the Control of Salmonellae in Various Foods; Destruction des Salmonellae par les Rayonnements dans Divers Produits Alimentaires; Primenenie izluchenij dlya unichtozheniya salmonell v razlichnykh pishchevykh produktakh; Empleo de las Radiaciones Ionizantes en la Lucha Contra las Salmonellae de Diferentes Aumentos

    Energy Technology Data Exchange (ETDEWEB)

    Ley, F. J. [Wantage Research Laboratory (A.E.R.E.), Wantage, Berks. (United Kingdom)

    1966-11-15

    serologiques presentes. Etant donne que ces conditions ne peuvent jamais etre reproduites exactement en laboratoire, le choix de la dose doit etre confirme par des recherches suffisamment etendues sur le meme produit contamine par voie naturelle. Il est apparu que, pour traiter differents produits alimentaires, il faut utiliser des doses comprises entre 0,5 et.1,0 Mrad qui permettent de reduire d'un facteur allant de 10{sup 5} a 10{sup 7} l'importance numerique des populations initiales. Les procedes qui semblent devoir donner de meilleurs resultats sont ceux que l'on envisage d'utiliser pour les produits a base d'oeufs congeles et deshydrates, les viandes congelees et les produits destines a l'alimentation animale. (author) [Spanish] Los estudios microbiologicos sobre el empleo de las radiaciones ionizantes para eliminar las Salmonellae de varios alimentos muestran que en la radiosensibilidad de esos microorganismos puede influir toda una serie de factores. Entre estos cabe citar la naturaleza del propio alimento y su temperatura durante la irradiacion, por ejemplo, si esta congelado o sin congelar. Tambien se han puesto claramente de manifiesto las diferencias de resistencia de distintos serotipos de Salmonellae irradiados en identicas condiciones. Por consiguiente, las curvas de dosis/supervivencia, que se preparen con el fin de seleccionar la dosis para una aplicacion particular, deben trazarse con arreglo a las condiciones practicas que se prevean y basarse en el serotipo mas resistente de los presentes. Como estas condiciones nunca pueden reproducirse exactamente en el laboratorio, la eleccion de la dosis debe confirmarse realizando amplios trabajos con alimentos naturalmente contaminados. Se llega a la conclusion de que las dosis necessarias para tratar varios alimentos son del orden de 0,5 a 1,0 Mrad, con lo que se logra reducir entre 10{sup 5} y 10{sup 7} veces la poblacion inicial. Los procedimientos mas interesantes son los aplicados a los huevos congelados y

  13. Gamma transitions in 127Te

    International Nuclear Information System (INIS)

    Batista, Wagner Fonseca; Zamboni, Cibele Bugno

    2009-01-01

    This study of the 127 Te β - decay was carried out by means of gamma spectroscopy measurements using high resolution Ge detector, in the region from 150 keV up to 1000 keV, aiming to get a better understanding of the 127 Te nuclear structure. Several gamma transitions were confirmed when compared with those published in the last compilation. These data resulting in lower uncertainty. (author)

  14. About cosmic gamma ray lines

    Science.gov (United States)

    Diehl, Roland

    2017-06-01

    Gamma ray lines from cosmic sources convey the action of nuclear reactions in cosmic sites and their impacts on astrophysical objects. Gamma rays at characteristic energies result from nuclear transitions following radioactive decays or high-energy collisions with excitation of nuclei. The gamma-ray line from the annihilation of positrons at 511 keV falls into the same energy window, although of different origin. We present here the concepts of cosmic gamma ray spectrometry and the corresponding instruments and missions, followed by a discussion of recent results and the challenges and open issues for the future. Among the lessons learned are the diffuse radioactive afterglow of massive-star nucleosynthesis in 26Al and 60Fe gamma rays, which is now being exploited towards the cycle of matter driven by massive stars and their supernovae; large interstellar cavities and superbubbles have been recognised to be of key importance here. Also, constraints on the complex processes making stars explode as either thermonuclear or core-collapse supernovae are being illuminated by gamma-ray lines, in this case from shortlived radioactivities from 56Ni and 44Ti decays. In particular, the three-dimensionality and asphericities that have recently been recognised as important are enlightened in different ways through such gamma-ray line spectroscopy. Finally, the distribution of positron annihilation gamma ray emission with its puzzling bulge-dominated intensity disctribution is measured through spatially-resolved spectra, which indicate that annihilation conditions may differ in different parts of our Galaxy. But it is now understood that a variety of sources may feed positrons into the interstellar medium, and their characteristics largely get lost during slowing down and propagation of positrons before annihilation; a recent microquasar flare was caught as an opportunity to see positrons annihilate at a source.

  15. Notes on the gamma kernel

    DEFF Research Database (Denmark)

    Barndorff-Nielsen, Ole E.

    The density function of the gamma distribution is used as shift kernel in Brownian semistationary processes modelling the timewise behaviour of the velocity in turbulent regimes. This report presents exact and asymptotic properties of the second order structure function under such a model......, and relates these to results of von Karmann and Horwath. But first it is shown that the gamma kernel is interpretable as a Green’s function....

  16. Analysis of FT-IR for dosimetric characterization of poly(vinylidene fluoride - hexafluoropropylene) irradiated with high doses of gamma radiation; Analise de FT-IR para caracterizacao dosimetrica do poli(fluoreto de vinilideno - hexafluorpropileno) irradiado com altas doses de radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Liz, Otavio Souza Rocha; Medeiros, Adriana de Souza [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear; Faria, Luiz Oliveira de, E-mail: farialo@cdtn.b [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2011-10-26

    Polymeric materials when exposed to ionizing radiation undergo changes such as the crosslinking and chain oxidation. Recently, the optical absorption intensities in the ultraviolet visible region (273 nm) due to radio- induction of conjugated C=C bonds in P(VDF-TrFE) copolymers has been successfully used for high dose dosimetry purposes in gamma fields ranging from 0.1 to 200 kGy. In this context, the interest of performing a systematic investigation on another fluorinated copolymer of PVDF, the (Polyvinylidene fluoride - hexa fluoro propylene) [P(VDF- HFP)] has come to light, not only for UV-VIS range but also for the near and medium infrared ranges. In this investigation FTIR and UV-Vis spectra, acquired before and after irradiation, were used to investigate the relationship between optical absorbance and delivered gamma doses ranging from 100 to 3,000 kGy. The results indicate that the absorption band at 1729 cm-1, originated by the chain oxidation through the radioinduction of C=O bonds, presents an unambiguous behavior with the delivered gamma doses in a very large extension, ranging from 0 to 1,000 kGy. This results lead to conclude that P(VDF-HFP) copolymer shows excellent dosimetric properties which make it able to be investigated as a high dose dosimeter

  17. Gamma camera system

    International Nuclear Information System (INIS)

    Miller, D.W.; Gerber, M.S.

    1982-01-01

    The invention provides a composite solid state detector for use in deriving a display, by spatial coordinate information, of the distribution or radiation emanating from a source within a region of interest, comprising several solid state detector components, each having a given surface arranged for exposure to impinging radiation and exhibiting discrete interactions therewith at given spatially definable locations. The surface of each component and the surface disposed opposite and substantially parallel thereto are associated with impedence means configured to provide for each opposed surface outputs for signals relating the given location of the interactions with one spatial coordinate parameter of one select directional sense. The detector components are arranged to provide groupings of adjacently disposed surfaces mutually linearly oriented to exhibit a common directional sense of the spatial coordinate parameter. Means interconnect at least two of the outputs associated with each of the surfaces within a given grouping for collecting the signals deriving therefrom. The invention also provides a camera system for imaging the distribution of a source of gamma radiation situated within a region of interest

  18. Gamma irradiation of meat

    International Nuclear Information System (INIS)

    Whitburn, K.D.; Hoffman, M.Z.; Taub, I.A.

    1982-01-01

    In ''A Re-Evaluation of the Products of Gamma Irradiation of Beef Ferrimyoglobin'', J. Food Sci. 46:1814 (1981), authors Whitburn, Hoffman and Taub state that color pigment myoglobin (Mb) undergoes chemical changes during irradiation that cause color changes in meat. They also state that they are in disagreement with Giddings and Markakis, J. Food Sci. 47:361 (1972) in regard to generation of MbO 2 in deaerated solutions, claiming their analysis demonstrates only Mb and Mb(IV) production. Giddings, in a letter, suggests that Whitburn, et al may have used differing systems and approaches which critically changed the radiation chemistry. He also states that radiation sterilization of aerobically packaged meats affects color only slightly. Whitburn, in a reply, shares Dr. Giddings concern for caution in interpretation of results for this system. The compositional changes are dependent on identity of free radicals, dose, O 2 and the time of analysis after irradiation. The quantification of these parameters in pure systems, sarcoplasma extracts and in meat samples should lead to a better understanding of color change mechanisms and how to minimize them

  19. Gamma radiation and chickens

    International Nuclear Information System (INIS)

    Toropilova, D.; Takac, L.; Toropila, M.; Tomko, M. M.

    2014-01-01

    In our work, we focused the effect of low doses of gamma radiation on metabolic parameters in chickens. In the first group of chickens we monitor changes of the concentration in glucose and cholesterol after whole body irradiation dose of chicken (3 Gy). In the second group of chickens we studied the combined effect of radiation and intraperitoneal application solution of zinc chloride to changes of the concentration in glucose and total cholesterol. In the tissues of organisms are found only in a very small amount of microelements however are of particular importance in a number of enzymatic catalytic and regulatory processes. Zinc is found in all cells of the body. However, it is the highest percentage of zinc contained in muscle and bone cells. Resorption takes place in the small intestine, especially in the duodenum. For both groups of chickens, we performed analyzes on the 3 rd , 7 th , 14 th , 21 st and 30 day. Results and an overview of the work can be helpful in the peaceful uses of nuclear energy and in preventing diseases from exposure to radiation, but also in the case of the consequences after nuclear accidents. (authors)

  20. Spontaneous Gamma Activity in Schizophrenia.

    Science.gov (United States)

    Hirano, Yoji; Oribe, Naoya; Kanba, Shigenobu; Onitsuka, Toshiaki; Nestor, Paul G; Spencer, Kevin M

    2015-08-01

    A major goal of translational neuroscience is to identify neural circuit abnormalities in neuropsychiatric disorders that can be studied in animal models to facilitate the development of new treatments. Oscillations in the gamma band (30-100 Hz) of the electroencephalogram have received considerable interest as the basic mechanisms underlying these oscillations are understood, and gamma abnormalities have been found in schizophrenia (SZ). Animal models of SZ based on hypofunction of the N-methyl-d-aspartate receptor (NMDAR) demonstrate increased spontaneous broadband gamma power, but this phenomenon has not been identified clearly in patients with SZ. To examine spontaneous gamma power and its relationship to evoked gamma oscillations in the auditory cortex of patients with SZ. We performed a cross-sectional study including 24 patients with chronic SZ and 24 matched healthy control participants at the Veterans Affairs Boston Healthcare System from January 1, 2009, through December 31, 2012. Electroencephalograms were obtained during auditory steady-state stimulation at multiple frequencies (20, 30, and 40 Hz) and during a resting state in 18 participants in each group. Electroencephalographic activity in the auditory cortex was estimated using dipole source localization. Auditory steady-state response (ASSR) measures included the phase-locking factor and evoked power. Spontaneous gamma power was measured as induced (non-phase-locked) gamma power in the ASSR data and as total gamma power in the resting-state data. The ASSR phase-locking factor was reduced significantly in patients with SZ compared with controls for the 40-Hz stimulation (mean [SD], 0.075 [0.028] vs 0.113 [0.065]; F1,46 = 6.79 [P = .012]) but not the 20- or the 30-Hz stimulation (0.042 [0.038] vs 0.043 [0.034]; F1,46 = 0.006 [P = .938] and 0.084 [0.040] vs 0.098 [0.050]; F1,46 = 1.605 [P = .212], respectively), repeating previous findings. The mean [SD] broadband-induced (30

  1. Cosmic gamma-ray burst

    International Nuclear Information System (INIS)

    Yamagami, Takamasa

    1985-01-01

    Ballon experiments for searching gamma-ray burst were carried out by employing rotating-cross modulation collimators. From a very long observation of total 315 hours during 1975 to 1979, three gamma-ray intensity anomalies were observed which were speculated as a gamma-ray burst. As for the first gamma-ray intensity anomaly observed in 1975, the burst source could be located precisely but the source, heavenly body, could not be specified. Gamma-ray burst source estimation was made by analyzing distribution of burst source in the celestial sphere, burst size distribution, and burst peak. Using the above-mentioned data together with previously published ones, apparent inconsistency was found between the observed results and the adopted theory that the source was in the Galaxy, and this inconsistency was found due to the different time profiles of the burst observed with instruments of different efficiency. It was concluded by these analysis results that employment of logN - logP (relation between burst frequency and burst count) was better than that of logN - logS (burst size) in the examination of gamma-ray burst because the former was less uncertain than the latter. Analyzing the author's observed gamma-ray burst data and the related published data, it was clarified that the burst distribution was almost P -312 for the burst peak value larger than 10 -6 erg/cm 2 .sec. The author could indicate that the calculated celestial distribution of burst source was consistent with the observed results by the derivation using the logN - logP relationship and that the burst larger than 10 -6 erg/cm 2 .sec happens about one thousand times a year, about ten times of the previous value. (Takagi, S.)

  2. Compton Gamma-Ray Observatory

    Science.gov (United States)

    1991-01-01

    This photograph shows the Compton Gamma-Ray Observatory (GRO) being deployed by the Remote Manipulator System (RMS) arm aboard the Space Shuttle Atlantis during the STS-37 mission in April 1991. The GRO reentered Earth atmosphere and ended its successful mission in June 2000. For nearly 9 years, the GRO Burst and Transient Source Experiment (BATSE), designed and built by the Marshall Space Flight Center (MSFC), kept an unblinking watch on the universe to alert scientists to the invisible, mysterious gamma-ray bursts that had puzzled them for decades. By studying gamma-rays from objects like black holes, pulsars, quasars, neutron stars, and other exotic objects, scientists could discover clues to the birth, evolution, and death of stars, galaxies, and the universe. The gamma-ray instrument was one of four major science instruments aboard the Compton. It consisted of eight detectors, or modules, located at each corner of the rectangular satellite to simultaneously scan the entire universe for bursts of gamma-rays ranging in duration from fractions of a second to minutes. In January 1999, the instrument, via the Internet, cued a computer-controlled telescope at Las Alamos National Laboratory in Los Alamos, New Mexico, within 20 seconds of registering a burst. With this capability, the gamma-ray experiment came to serve as a gamma-ray burst alert for the Hubble Space Telescope, the Chandra X-Ray Observatory, and major gound-based observatories around the world. Thirty-seven universities, observatories, and NASA centers in 19 states, and 11 more institutions in Europe and Russia, participated in the BATSE science program.

  3. Estrategias para negociaciones exitosas.

    OpenAIRE

    José B. Parra V; Evelinda Santiago J.; Misael Murillo M.; Candy Atonal N.

    2010-01-01

    Las estrategias de negociación son herramientas para disminuir conflictos o para intercambiar bienes y servicios. Una negociación exitosa crea relaciones de solidaridad y propicia reciprocidad, cooperación y confianza para quienes tendrán relaciones permanentes de negociación con beneficios para ambas partes. Una estrategia de negociación exitosa requiere manejar el desarrollo del ambiente social del grupo de personas, con la finalidad de tener presente las fronteras que no pueden irrumpirse....

  4. The Gamma-ray Sky with Fermi

    Science.gov (United States)

    Thompson, David

    2012-01-01

    Gamma rays reveal extreme, nonthermal conditions in the Universe. The Fermi Gamma-ray Space Telescope has been exploring the gamma-ray sky for more than four years, enabling a search for powerful transients like gamma-ray bursts, novae, solar flares, and flaring active galactic nuclei, as well as long-term studies including pulsars, binary systems, supernova remnants, and searches for predicted sources of gamma rays such as dark matter annihilation. Some results include a stringent limit on Lorentz invariance derived from a gamma-ray burst, unexpected gamma-ray variability from the Crab Nebula, a huge gamma-ray structure associated with the center of our galaxy, surprising behavior from some gamma-ray binary systems, and a possible constraint on some WIMP models for dark matter.

  5. Low-Level {beta} and {gamma} Counting in the Region 0-10 Disintegrations Per Minute; Comptage {beta} et {gamma} d'echantillons de faible activite (0 a 10 desintegrations par minute); Izmerenie {beta}- i {gamma}-izlucheniya maloj moshchnosti (0-10 raspadov v minutu); Recuento {beta} y {gamma} de muestras de baja actividad (0 a 10 desintegraciones por minuto)

    Energy Technology Data Exchange (ETDEWEB)

    Manov, George G [Tracerlab Inc. (United States)

    1960-06-15

    transistors, y compris les preamplificateur s et alimentations, sont plus satisfaisants que les dispositifs classiques fonctionnant avec des tubes a vide. (author) [Spanish] La medicion de niveles de radiactividad en el intervalo comprendido entre 0 y 10 desintegraciones por minuto presenta cada dia mayor utilidad para la normalizacion de radionuclidos, asi como en otras ramas de la ciencia tales como la geologia y la medicina. Por ejemplo, resulta a menudo necesario efectuar el recuento de las radiaciones emitidas por muestras de baja actividad en la esfera de las aplicaciones biologicas y de los trazadores, especialmente en aquellos casos en que el empleo de una radiactividad mas elevada alteraria la marcha de la operacion o del proceso que se estudia. Con frecuencia, es preciso realizar esas mediciones en condiciones en que la actividad de la muestra apenas represente el 1% de la radiacion de fondo en ausencia de toda proteccion. En otros casos, se impone otra limitacion por el hecho de que el radionuclido tiene un periodo de semidesintegracio n muy corto. En general, pueden seguirse tres procedimientos para aumentar la exactitud en el recuento de radiaciones de bajo nivel: utilizacion de contadores mas eficientes, correcciones del fondo mas pequenas y empleo de sistemas electronicos mas estables y libres de interferencias. En esta memoria se comparan los resultados de las pruebas llevadas a cabo con el proposito de averiguar las ventajas relativas de tres tipos distintos de contadores de anticoincidencia en lo que atane a la reduccion del fondo. A tal efecto, se efectuaron mediciones con contadores: a) tipo hongo, b) anular y c) ''igloo'' plastico de centelleo. Causa alguna preocupacion la creciente dificultad de obtener materiales inactivos para la construccion de contadores. Se ofrecen datos sobre los niveles de radiactividad de los distintos materiales que pueden adquirirse en el comercio. Se esta agudizando rapidamente la necesidad de constituir reservas de dichos

  6. Problems of calibrating measuring instruments for selective gamma-gamma logging

    International Nuclear Information System (INIS)

    Daniel, J.; Smolarova, H.

    1977-01-01

    Quantitative determination of copper content in the Novoveska Huta chalcopyrite deposit is described using selective gamma-gamma logging. Factors influencing the calibration quality are discussed. (author)

  7. GammaModeler 3-D gamma-ray imaging technology

    International Nuclear Information System (INIS)

    2000-01-01

    The 3-D GammaModelertrademark system was used to survey a portion of the facility and provide 3-D visual and radiation representation of contaminated equipment located within the facility. The 3-D GammaModelertrademark system software was used to deconvolve extended sources into a series of point sources, locate the positions of these sources in space and calculate the 30 cm. dose rates for each of these sources. Localization of the sources in three dimensions provides information on source locations interior to the visual objects and provides a better estimate of the source intensities. The three dimensional representation of the objects can be made transparent in order to visualize sources located within the objects. Positional knowledge of all the sources can be used to calculate a map of the radiation in the canyon. The use of 3-D visual and gamma ray information supports improved planning decision-making, and aids in communications with regulators and stakeholders

  8. Use of microcontroller in gamma-ray spectrometer construction using NaI(Tl) sensor, with emphasis in multichannel analyzer, to applications in nuclear and environmental geophysics; Uso de microcontrolador na construcao de espectrometro gama com sensor de NaI(Tl), com enfase em analisador multicanal, para aplicacao em geofisica nuclear e ambiental

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Nilton

    2005-07-01

    In this work of nuclear geophysical instrumentation the main purpose was the development of a gamma-ray spectrometer prototype with multi channel analyzer, since the spectroscopic amplifier until your firmware. The heart of the digital part was an ATMEL 8 bits microcontroller (AT89S8252). All circuits were made and assembled in the Laboratory of Applied Geophysical Instrumentation (LIGA) of IAG-USP. A microcontroller software was completely developed in C ANSI language using the Small Device C Compiler version 2.4.8, that is a free software distributed under General Public License (GPL). At first, microcontroller was used to change all digital circuit of one classic SCINTREX GAD-6 differential gamma-ray spectrometer. Measurement times with order of 2 days became possible, and it could work in non climate ambient. Then, after this stage, had been started the development of a multichannel analyzer (MCA) working in pulse height analyzer mode with 4096 channels capacity, to use in many kinds of nuclear detection. Besides it, was developed an automatic gain system for photopeak stabilization, by the use of one radioactive source ({sup 133}Ba). This automatic gain system is very important in the case of NaI(Tl) scintillometric detectors, due PMT sensitivity with temperature and aging of some laboratory electronic circuits. Two power supplies with high stability, using pulse width modulation (PWM) techniques were developed, in order to all system became free of electrical line break off. One PWM power polarizes a photo multiplier tube (PMT) with high voltage and another supplies remaining developed circuits. Calibration in energy using standards sources {sup 137}Cs and {sup 60}Co showed that gamma detector developed has a good linearity and low thermal drift, even working in absent of air-conditioned. Concentrations measurements of K, U and Th were made in samples of soils, vegetables, etc. (author)'

  9. Synthesis, Characterization, and Nonlinear Optical Properties of P-Substituted Poly Gamma-Benzyl

    Science.gov (United States)

    Choi, Dong-Hoon

    Poly gamma-benzyl-L-glutamate (PBLG), poly gamma-p-fluorobenzyl -L-glutamate (PGLU(pFB)), poly gamma -p-nitrobenzyl-L-glutamate (PGLU(pNB)), and poly gamma-p-trifluoromethylbenzyl-L-glutamate (PGLU(pTFMB)) have been synthesized. These PBLG polymers show variations in the side chain conformations in the solid state and solution state. In the solid state, the side chain orientation was assigned to a longitudinal or transverse direction by virtue of the polarized infrared spectrum of each PBLG analogue. The characteristics of the lyotropic liquid crystalline behavior could be observed. The optical waveguiding property of these polymers facilitated measurement of the refractive index and the thickness of each polymer film. Poling the polymer films and using the simple reflection technique, the electro -optic coefficients of the PBLG analogues could be determined. The effect of the para substitution on benzyl ester as it effected the electro-optic coefficient and the relation between the dielectric properties and the electro-optic effect of each polymer were investigated. These studies were able to demonstrate which conformation of the side chain in para substituted poly gamma-benzyl -L-glutamates is a more favorable conformation for enhancing the electro-optic behavior of these polymers.

  10. Extragalactic Gamma-Ray Astrophysics

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    During the last decades, various classes of radio-loud active galactic nuclei have been established as sources of high-energy radiation extending over a very broad range from soft gamma-rays (photon energies E~MeV) up to very-high-energy gamma-rays (E>100 GeV). These include blazars of different types, as well as young and evolved radio galaxies. The observed gamma-ray emission from such implies efficient particle acceleration processes taking place in highly magnetized and relativistic jets produced by supermassive black holes, processes that have yet to be identified and properly understood. In addition, nearby starforming and starburst galaxies, some of which host radio-quiet Seyfert-type nuclei, have been detected in the gamma-ray range as well. In their cases, the observed gamma-ray emission is due to non-thermal activity in the interstellar medium, possibly including also a contribution from accretion disks and nuclear outflows. Finally, the high-energy emission from clusters of galaxies remains elusive...

  11. Quality assurance for gamma knives

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Fischer, L.E.

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations

  12. Quality assurance for gamma knives

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations.

  13. Design and implementation of a virtual laboratory of radiation measurement; Diseno e implementacion de un laboratorio virtual de medicion de radiaciones

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez T, J. R.; Morales S, J. B. [Facultad de Ingenieria, UNAM, Ciudad Universitaria, 04510 Mexico, D. F. (Mexico)], e-mail: jms0620@yahoo.com.mx

    2009-10-15

    The work involves the implementation of a virtual laboratory, this project is conducted in the Faculty of Engineering of National Autonomous University of Mexico with the name of LANUVI. It is intended that the laboratory can be used by students who have interest in the nuclear radiation knowledge as well as in its detection and attenuation, in addition serve as and introduction to nuclear systems. In the first part of project will conduct a source that can simulate the particle radiation of Alfa, beta, neutrons and gamma rays. The project will take sources used in class laboratories and elements that are dangerous but are used in different practical applications. After taking the source analyzing the particles behaviour in different media like air, animal tissue, aluminium, lead, etc. The analysis is done in different ways in order to know with which material can stop or mitigate the different types of radiation. Finally shall be measure radioactivity with different types of detectors. At this point, has the behaviour of ionization chamber but in the future is expected to make the simulation of some other radiation detectors. The mathematical models we represent the behaviour of these cases were implemented in free software. The program will be used to implement the virtual laboratory with radiation sources, detectors and different types of shields will be Blender which is a free software that is used by many users for the embodiment of games but try to use as a tool to help visualize the different equipment that is widely used in a radioactive materials laboratory. (Author)

  14. Effect of electromagnetic radiation on the physico-chemical properties of minerals; Efecto de la radiacion electromagnetica en las propiedades fisicoquimicas de los minerales

    Energy Technology Data Exchange (ETDEWEB)

    Lopez M, A.; Delgadillo G, J. A. [Universidad Autonoma de San Luis Potosi, Instituto de Metalurgia, Doctorado Institucional de Ingenieria y Ciencia de Materiales, Av. Sierra Leona 550, 78210 San Luis Potosi (Mexico); Vega C, H. R., E-mail: alopezm6@yahoo.com.mx [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Cipres No. 10, Fracc. La Penuela, 98068 Zacatecas (Mexico)

    2014-08-15

    The electromagnetic radiation effect represented by gamma rays was investigated through; chemical analysis, X-ray diffraction (XRD), scanning electron microscopy (Sem) and magnetization when applied at a dose of 0.5704 Gy (0.5704 J/ kg) at a feed relation of 18.40 ± 1.13 mGy/ h., in different minerals; in order to characterize the impact of the same from {sup 137}Cs in the physicochemical properties of these minerals. All the irradiated samples showed chemical stability at this stage undetectable other both in the XRD study and in the images analysis obtained by Sem; and at present almost the same chemical composition as the non-irradiated samples. So the same patterns of X-ray diffraction thereof, show a tendency to slightly lower the intensity of the most representative peaks of each mineral phase, which may be due to a decrease in crystallinity or preferential crystallographic orientation in crystals. In the micrographs analysis obtained by Sem on the irradiated samples, some holes (open pores) present in the particles were observed, mainly chalcopyrite and sphalerite lesser extent, seen this fact may be due to Compton Effect, in the radiation process. In relation to the magnetization property, a variation is obtained in the saturation magnetization (Ms) for the irradiated samples containing iron and more significantly in the chalcopyrite case. Therefore, with the radiation level used; slight changes occurring in the physical properties of minerals, whereas they remained stable chemically. These small changes may represent a signal that electromagnetic radiation applied at higher doses, is a viable option for improving the mineral processing. (author)

  15. Optical observations of Gamma-Ray Bursts

    International Nuclear Information System (INIS)

    Hjorth, J.; Pian, E.; Fynbo, J.P.U.

    2004-01-01

    We briefly review the status and recent progress in the field of optical observations of gamma-ray burst afterglows. We will focus on the fundamental observational evidence for the relationship between gamma-ray bursts and the final evolutionary phases of massive stars. In particular, we will address (i) gamma-ray burst host galaxies, (ii) optically dark gamma-ray burst afterglows, (iii) the gamma-ray burst-supernova connection, and (iv) the relation between X-ray flashes, gamma-ray bursts, and supernovae

  16. Equipment for x- and gamma ray radiography

    International Nuclear Information System (INIS)

    Abd Nasir Ibrahim; Azali Muhammad; Ab Razak Hamzah; Abd Aziz Mohamed; Mohammad Pauzi Ismail

    2004-01-01

    The following topics related to the equipment for x - and gamma ray radiography are discussed in this chapter. The topics are x-ray source for Industrial Radiography: properties of x-ray, generation of x-ray, mechanism of x-ray production, x-ray equipment, power supply, distribution of x-ray intensity along the tube: gamma ray source for Industrial Radiography: properties of gamma rays, gamma ray sources, gamma ray projectors on cameras, source changing. Care of Radiographic Equipments: Merits and Demerits of x and Gamma Rays

  17. Effects of Monoenergetic Neutron Radiation on Human Cells in Tissue Culture; Effets des Neutrons Monoenergetiques sur des Cellules de Tissus Humains en Culture; Dejstvie oblucheniya monoehnergeticheskimi nejtronami na kletki kul'tury tkanej cheloveka; Efectos de la Radiacion Neutronica Monoenergetica sobre las Celulas Humanas en Cultivos de Tejidos

    Energy Technology Data Exchange (ETDEWEB)

    Broerse, J. J.; Barendsen, G. W. [Radiobiological Institute of the Organization for Health Research TNO, Rijswijk (Z.H.) (Netherlands)

    1964-03-15

    determinaron midiendo la activacion de unas pastillas de azufre dispuestas entre las capsulas y los tubos. El calculo de las dosis a partir del flujo neutronico plantea una serie de problemas que los autores analizan. Como no se establece un equilibrio de radiacion en torno a las celulas, las respectivas determinaciones de dosis adolecen de falta de precision que se investigan en el trabajo. Los autores presentan curvas de la supervivencia en funcion de la dosis, para las dos energias neutronicas mencionadas. Con los neutrones de 3 MeV, comprobaron que la EBR varia desde 6,5 (dosis reducidas) hasta alrededor de 3,1 (dosis elevadas); con los neutrones de 15 MeV, la EBR varia entre 1,9 y 1,6. Combinando estos valores de la EBR con la relacion entre la TLE y la EBR establecida en experimentos previos con deuterones y particulas {alpha}, se pueden deducir valores de la TLE efectiva correspondientes a los neutrones utilizados. A fin de dilucidar algunos problemas relacionados con la muerte de animales de laboratorio sometidos a la accion de los rayos X o de los neutrones, los autores perfeccionaron un procedimiento basado en el empleo de celulas, contenidas en pequeflos tubos a fin de medir la dosis efectiva (es decir, la dosis corregida para tener en cuenta la EBR) en zonas determinadas de maniquies o de animales, que ofrecen interes para estos estudios. (author) [Russian] Soobshhaetsja o sootnoshenii doza-jeffekt na osnovanii izluchenija tormozhenija obrazovanija klona pochechnymi kletkami cheloveka posle obluchenija monojenergeticheskimi nejtronami s jenergiej primerno 3 Mjev i 15 Mjev. Dlja nejtronov s jenergiej 3 Mjev moshhnost' dozy ravnjalas' 0,2 rad/min, v to vremja kak dlja nejtronov s jenergiej v 15 Mjev byli polucheny moshhnosti dozy v 2,7 rad/min i 12 rad/min. Obluchenie kletok proizvodilos' v chashkah dlja kul'tury tkanej s tonkim dnom iz stekla Melimeks i v nebol'shih gibkih nejlonovyh rezinovyh trubkah. Potoki nejtronov opredeljalis' putem izmerenija aktivacii sernyh

  18. Design and Performance of the GAMMA-400 Gamma-Ray Telescope for Dark Matter Searches

    Science.gov (United States)

    Galper, A. M.; Adriani, O.; Aptekar, R. L.; Arkhangelskaja, I. V.; Arkhangelskiy, A. I.; Boezio, M.; Bonvicini, V.; Boyarchuk, K. A.; Fradkin, M. I.; Gusakov, Yu V.; hide

    2012-01-01

    The GAMMA-400 gamma-ray telescope is designed to measure the fluxes of gamma-rays and cosmic-ray electrons (+) positrons, which can be produced by annihilation or decay of the dark matter particles, as well as to survey the celestial sphere in order to study point and extended sources of gamma-rays, measure energy spectra of Galactic and extragalactic diffuse gamma-ray emission, gamma-ray bursts, and gamma-ray emission from the Sun. GAMMA-400 covers the energy range from 100 MeV to 3000 GeV. Its angular resolution is approximately 0.01deg (E(sub gamma) greater than 100 GeV), the energy resolution approximately 1% (E(sub gamma) greater than 10 GeV), and the proton rejection factor approximately 10(exp 6). GAMMA-400 will be installed on the Russian space platform Navigator. The beginning of observations is planned for 2018.

  19. The high intensity {gamma}-ray source (HI{gamma}S) and recent results

    Energy Technology Data Exchange (ETDEWEB)

    Tonchev, A.P. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States)]. E-mail: tonchev@tunl.duke.edu; Boswell, M. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Howell, C.R. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Karwowski, H.J. [University of North Carolina at Chapel Hill and TUNL, Chapel Hill, NC 27599 (United States); Kelley, J.H. [North Carolina State University and TUNL, Raleigh, NC 27695 (United States); Tornow, W. [Duke University and TUNL, Triangle University Nuclear Laboratory, P.O. Box 90308, Durham, NC 27708 0308 (United States); Wu, Y.K. [Duke University and Duke Free Electron Laser Laboratory, Durham, NC 27708-0319 (United States)

    2005-12-15

    The high intensity {gamma}-ray source (HI{gamma}S) utilizes intra-cavity backscattering of free electron laser photons from the Duke electron storage ring to produce a unique monoenergetic beam of high-flux {gamma}-rays with high polarization and selectable energy resolution. At present, {gamma}-ray beams with energies from 2 to 58 MeV are available with intensities as high as 10{sup 5}-5 x 10{sup 6} {gamma}/s, energy spreads of 3% or better, and nearly 100% linear polarization. The quality and intensity of the {gamma}-ray beams at HI{gamma}S are responsible for the unprecedented performance of this facility in a broad range of research programs in nuclear structure, nuclear astrophysics and nuclear applications. Recent results from excitation of isomeric states in ({gamma}, n) reactions and parity assignments of dipole states determined via the ({gamma}, {gamma}') reaction are presented.

  20. Subvenciones para instituciones Directrices para gastos de ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    IDRC CRDI

    División de Administración de Subvenciones ... En la Parte 2 del Acuerdo de Subvención estándar de IDRC se incluyen los límites ... pagar los costos de sustitución (tiempo libre para personal académico) de los investigadores principales.

  1. Gamma irradiators for radiation processing

    International Nuclear Information System (INIS)

    2006-01-01

    Radiation technology is one of the most important fields which the IAEA supports and promotes, and has several programmes that facilitate its use in the developing Member States. In view of this mandate, this Booklet on 'Gamma Irradiators for Radiation Processing' is prepared which describes variety of gamma irradiators that can be used for radiation processing applications. It is intended to present description of general principles of design and operation of the gamma irradiators available currently for industrial use. It aims at providing information to industrial end users to familiarise them with the technology, with the hope that the information contained here would assist them in selecting the most optimum irradiator for their needs. Correct selection affects not only the ease of operation but also yields higher efficiency, and thus improved economy. The Booklet is also intended for promoting radiation processing in general to governments and general public

  2. Automation of gamma-therapy

    International Nuclear Information System (INIS)

    Al'bitskij, L.L.; Brikker, I.N.; Bychkov, V.N.; Voronin, V.V.; Mirzoyan, A.R.; Rogozhin, A.S.; Sarkisyan, Yu.Kh.

    1989-01-01

    A system of automated control Aspect-2 was developed for automation of gamma therapy on units of the Rokus series. The system consists of the following hardware and software complexes: a complex of preirradiation preparation Centrator-imitator, a complex Accord for anatomotopographic data coding; a software complex and a gamma-therapeutic complex Rokus-AM. The Centrator-imitator and Rokus-AM complexes are fitted out with built-in microcomputers with specially developed systemic software. The Rokus-AM complex has automatic punch tape programmed control of 9 degrees of freedom of the gamma-unit and treatment table and ensures 5 modes of irradiation: positional, rotating, rotaing-convergent, sectoral rotating-convergent and scanning

  3. Terrestrial gamma-ray flashes

    Science.gov (United States)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-08-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models.

  4. Terrestrial gamma-ray flashes

    International Nuclear Information System (INIS)

    Marisaldi, Martino; Fuschino, Fabio; Labanti, Claudio; Tavani, Marco; Argan, Andrea; Del Monte, Ettore; Longo, Francesco; Barbiellini, Guido; Giuliani, Andrea; Trois, Alessio; Bulgarelli, Andrea; Gianotti, Fulvio; Trifoglio, Massimo

    2013-01-01

    Lightning and thunderstorm systems in general have been recently recognized as powerful particle accelerators, capable of producing electrons, positrons, gamma-rays and neutrons with energies as high as several tens of MeV. In fact, these natural systems turn out to be the highest energy and most efficient natural particle accelerators on Earth. Terrestrial Gamma-ray Flashes (TGFs) are millisecond long, very intense bursts of gamma-rays and are one of the most intriguing manifestation of these natural accelerators. Only three currently operative missions are capable of detecting TGFs from space: the RHESSI, Fermi and AGILE satellites. In this paper we review the characteristics of TGFs, including energy spectrum, timing structure, beam geometry and correlation with lightning, and the basic principles of the associated production models. Then we focus on the recent AGILE discoveries concerning the high energy extension of the TGF spectrum up to 100 MeV, which is difficult to reconcile with current theoretical models

  5. Automatic gamma spectrometry analytical apparatus

    International Nuclear Information System (INIS)

    Lamargot, J.-P.; Wanin, Maurice.

    1980-01-01

    This invention falls within the area of quantitative or semi-quantitative analysis by gamma spectrometry and particularly refers to a device for bringing the samples into the counting position. The purpose of this invention is precisely to provide an automatic apparatus specifically adapted to the analysis of hard gamma radiations. To this effect, the invention relates to a gamma spectrometry analytical device comprising a lead containment, a detector of which the sensitive part is located inside the containment and additionally comprising a transfer system for bringing the analyzed samples in succession to a counting position inside the containment above the detector. A feed compartment enables the samples to be brought in turn one by one on to the transfer system through a duct connecting the compartment to the transfer system. Sequential systems for the coordinated forward feed of the samples in the compartment and the transfer system complete this device [fr

  6. Gamma radiometric survey of Jamaica

    International Nuclear Information System (INIS)

    Lalor, G.C.; Robotham, H.; Miller, J.M.; Simpson, P.R.

    1989-01-01

    The results of a total gamma radiometric survey of Jamaica, carried out with car-borne instrumentation, are presented and the data compared with the contents of potassium, thorium and uranium in rocks and in surface (soil, stream-sediment, pan concentrate and water) samples obtained at six sites selected to be representative of the principal rock types and surface environments of Jamaica. The work formed part of an orientation study for a regional geochemical survey of the CARICOM countries of the Caribbean. The initial results indicate that enhanced gamma activity is correlated with enrichment in uranium and thorium, but not potassium, in terra rossa soils and/or bauxite deposits in limestone. Elsewhere, gamma levels are increased on the Above Rocks Cretaceous basement Inlier, where they correlate generally with the presence of volcanogenic sediments and a granodiorite intrusion. The lowest radioactivity was recorded in the vicinity of ultrabasic rocks in the Blue Mountains Inlier. (author)

  7. Scintillation counter, maximum gamma aspect

    International Nuclear Information System (INIS)

    Thumim, A.D.

    1975-01-01

    A scintillation counter, particularly for counting gamma ray photons, includes a massive lead radiation shield surrounding a sample-receiving zone. The shield is disassembleable into a plurality of segments to allow facile installation and removal of a photomultiplier tube assembly, the segments being so constructed as to prevent straight-line access of external radiation through the shield into radiation-responsive areas. Provisions are made for accurately aligning the photomultiplier tube with respect to one or more sample-transmitting bores extending through the shield to the sample receiving zone. A sample elevator, used in transporting samples into the zone, is designed to provide a maximum gamma-receiving aspect to maximize the gamma detecting efficiency. (U.S.)

  8. Simulation of a gamma-camera for activity measurement of {sup 99m}Tc using the Monte Carlo Gate code; Simulação de uma gama-câmara para medidas de atividade de {sup 99m}Tc com o código de Monte Carlo Gate

    Energy Technology Data Exchange (ETDEWEB)

    Barrientos, C.P. Castro; Souza-Santos, D. [Instituto de Radioproteção e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil); Mação Junior, J.L.; Wunder, R.S.; Knust, I.C., E-mail: car_pcb@aluno.ird.gov.br [Hospital Naval Marcílio Dias, Rio de Janeiro, RJ (Brazil)

    2017-07-01

    Brazil has a growing demand for nuclear medicine services (NMS), and radiopharmaceuticals supplied by the National Nuclear Energy Commission (CNEN) provide approximately two million nuclear medicine (NM) procedures per year. Among these radiopharmaceuticals, one of the most used is {sup 99m}Tc. The manipulation of unsealed radioactive sources presents a risk of incorporation. Workers who handle radiopharmaceuticals in NM procedures should be subject to an internal individual monitoring program to optimize their practices as well as to ensure that dose limits are not exceeded. This program may require measuring the activity of incorporated radionuclides, done in a whole body counter. This measurement may prove impracticable due to the absence of dedicated systems, available to all workers in a country. One solution to this problem would be to perform the measurement of the incorporated activity using the Gamma camera of the NMS in which the occupationally exposed individual (IOE) works. The objective of this work is to simulate with the Monte Carlo method a Gamma camera, with the code Gate, validating the results for the {sup 99m}Tc through measurements performed in an NMS. Measurements of counts were taken around the 140 keV main peak, with and without the collimator, that were correlated with the source activity. The validation shows good agreement between the simulation and the experimental data, with a difference of about 3% for the simulation without the collimator and about 2% for the simulation with the collimator. (author)

  9. Investigation of gamma spectra analysis

    International Nuclear Information System (INIS)

    Wu Huailong; Liu Suping; Hao Fanhua; Gong Jian; Liu Xiaoya

    2006-01-01

    In the investigation of radiation fingerprint comparison, it is found out that some of the popular gamma spectra analysis software have shortcomings, which decrease the radiation fingerprint comparison precision. So a new analysis software is developed for solving the problems. In order to display the advantage of developed program, some typical simulative warhead gamma spectra are analyzed respectively by present software and GAMMAVISION and GENNIE2000. Present software can be applied not only in nuclear warheads deep-cuts verification, but also in any radiation measurement field. (authors)

  10. Gamma-ray burst spectra

    International Nuclear Information System (INIS)

    Teegarden, B.J.

    1982-01-01

    A review of recent results in gamma-ray burst spectroscopy is given. Particular attention is paid to the recent discovery of emission and absorption features in the burst spectra. These lines represent the strongest evidence to date that gamma-ray bursts originate on or near neutron stars. Line parameters give information on the temperature, magnetic field and possibly the gravitational potential of the neutron star. The behavior of the continuum spectrum is also discussed. A remarkably good fit to nearly all bursts is obtained with a thermal-bremsstrahlung-like continuum. Significant evolution is observed of both the continuum and line features within most events

  11. Gamma Radiation from Fission Fragments

    International Nuclear Information System (INIS)

    Higbie, Jack

    1969-10-01

    The gamma radiation from the fragments of the thermal neutron fission of 235 U has been investigated, and the preliminary data are presented here with suggestions for further lines of research and some possible interpretations of the data. The data have direct bearing on the fission process and the mode of fragment de-excitation. The parameters measured are the radiation decay curve for the time interval (1 - 7) x 10 -10 sec after fission, the photon yield, the total gamma ray energy yield, and the average photon energy. The last three quantities are measured as a function of the fragment mass

  12. A study of gamma shielding

    International Nuclear Information System (INIS)

    Roogtanakait, N.

    1981-01-01

    Gamma rays have high penetration power and its attenuation depends upon the thickness and the attenuation coefficient of the shield, so it is necessary to use the high density shield to attenuate the gamma rays. Heavy concrete is considered to be used for high radiation laboratory and the testing of the shielding ability and compressibility of various types of heavy concrete composed of baryte, hematite, ilmenite and galena is carried out. The results of this study show that baryte-ilmenite concrete is the most suitable for high radiation laboratory in Thailand

  13. Coincidence gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Markovic, Nikola; Roos, Per; Nielsen, Sven Poul

    2017-01-01

    Gamma-ray spectrometry with high-purity germanium (HPGe) detectors is often the technique of choice in an environmental radioactivity laboratory. When measuring environmental samples associated activities are usually low so an important parameter that describes the performance of the spectrometer...... for a nuclide of interest is the minimum detectable activity (MDA). There are many ways for lowering the MDAs in gamma spectrometry. Recently, developments of fast and compact digital acquisition systems have led to growing number of multiple HPGe detector spectrometers. In these applications all detected...

  14. Investigation of gamma spectra analysis

    International Nuclear Information System (INIS)

    Wu Huailong; Liu Suping; Hao Fanhua

    2006-12-01

    During the investigation of radiation fingerprint comparison, it is found out that the popular gamma spectra analysis softwares are faultful, which decrease the precision of radiation fingerprint comparison. So a new analysis software is development for solving the problems. In order to display the advantage of new program, some typical simulative gamma spectra of radiation source are analyzed respectively by our software and GAMMAVISION and GENNIE2000. The software can be applied not only in nuclear warheads deep-cuts verification, but also in any radiation measurement field. (authors)

  15. Gamma source for active interrogation

    Science.gov (United States)

    Leung, Ka-Ngo [Hercules, CA; Lou, Tak Pui [Berkeley, CA; Barletta, William A [Oakland, CA

    2009-09-29

    A cylindrical gamma generator includes a coaxial RF-driven plasma ion source and target. A hydrogen plasma is produced by RF excitation in a cylindrical plasma ion generator using an RF antenna. A cylindrical gamma generating target is coaxial with the ion generator, separated by plasma and extraction electrodes which has many openings. The plasma generator emanates ions radially over 360.degree. and the cylindrical target is thus irradiated by ions over its entire circumference. The plasma generator and target may be as long as desired.

  16. Gamma Radiation from Fission Fragments

    Energy Technology Data Exchange (ETDEWEB)

    Higbie, Jack

    1969-10-15

    The gamma radiation from the fragments of the thermal neutron fission of {sup 235}U has been investigated, and the preliminary data are presented here with suggestions for further lines of research and some possible interpretations of the data. The data have direct bearing on the fission process and the mode of fragment de-excitation. The parameters measured are the radiation decay curve for the time interval (1 - 7) x 10{sup -10} sec after fission, the photon yield, the total gamma ray energy yield, and the average photon energy. The last three quantities are measured as a function of the fragment mass.

  17. Gamma activation analysis with microtron

    International Nuclear Information System (INIS)

    Fiderkiewicz, A.; Kierzek, J.; Parus, J.; Swiderska-Kowalczyk, M.; Wolski, W.; Zoltowski, T.

    1989-01-01

    The physical principles of gamma activation analysis, its capabilities as well as its application to analyse polymetallic ores with use of mean power microtron are presented. Limits of detection and determination for above twenty elements occurring in those ores with use of short- and longlived radioisotopes are specified. The work contains conception of construction of race-track microtron with electrons energy adjusted in 10-30 MeV range and with current not less than 20 μA. Besides the development of microtrons, the reason for choosing the race-track construction for gamma activation analysis is given. 69 refs., 35 figs., 5 tabs. (author)

  18. Airborne gamma-ray spectrometry

    DEFF Research Database (Denmark)

    Hovgaard, Jens

    A new method - Noise Adjusted Singular Value Decomposition, NASVD - for processing gamma-ray spectra has been developed as part of a Ph.D. project. By using this technique one is able to decompose a large set of data - for example from airborne gamma-ray surveys - into a few spectral components....... By knowing the spectral components and their amplitudes in each of the measured spectra one is able to extract more information from the data than possible with the methods used otherwise....

  19. Cosmic gamma-ray bursts

    International Nuclear Information System (INIS)

    Hurley, K.

    1989-01-01

    This paper reviews the essential aspects of the gamma-ray burst (GRB) phenomenon, with emphasis on the more recent results. GRBs are introduced by their time histories, which provide some evidence for a compact object origin. The energy spectra of bursts are presented and they are seen to demonstrate practically unambiguously that the origin of some GRBs involves neutron stars. Counterpart searches are reviewed briefly and the statistical properties of bursters treated. This paper presents a review of the three known repeating bursters (the Soft Gamma Repeaters). Extragalactic and galactic models are discussed and future prospects are assessed

  20. Gamma-ray Imaging Methods

    Energy Technology Data Exchange (ETDEWEB)

    Vetter, K; Mihailescu, L; Nelson, K; Valentine, J; Wright, D

    2006-10-05

    In this document we discuss specific implementations for gamma-ray imaging instruments including the principle of operation and describe systems which have been built and demonstrated as well as systems currently under development. There are several fundamentally different technologies each with specific operational requirements and performance trade offs. We provide an overview of the different gamma-ray imaging techniques and briefly discuss challenges and limitations associated with each modality (in the appendix we give detailed descriptions of specific implementations for many of these technologies). In Section 3 we summarize the performance and operational aspects in tabular form as an aid for comparing technologies and mapping technologies to potential applications.

  1. Radiosurgery by Leksell gamma knife

    International Nuclear Information System (INIS)

    Novotny, Josef

    2008-01-01

    The learning objectives of the lecture were as follows: to learn basic principles of Leksell gamma knife (LGK) radiosurgery; to discuss imaging, treatment planning and optimization procedures; to discuss quality assurance for LGK treatments; and to present examples of diagnoses treated by LGK. The following topics were discussed: Radiosurgery - definition, components of selectivity, fundamentals; Leksell gamma knife - principles; Stereotactic target localization; Radiosurgery - imaging; Treatment planning; LGK treatment; Quality control - process tree, LGK, distortion of scanners, 3D phantom measurements; Physical and technical parameters; and Clinical applications. (P.A.)

  2. Effects of Acute Gamma Irradiation on Amaryllis Orange Bio gamma

    International Nuclear Information System (INIS)

    Sakinah Ariffin; Shakinah Salleh; Shuhaimi Shamsuddin; Suhaimi Musa; Affrida Abu Hassan

    2016-01-01

    Ornamental and landscaping plants have their own demand. Color variations, shape and flower shelf life are among the important value-added characters in improvement of new varieties of ornamental plants. Mutation induction using ionizing radiation is an alternative way for obtaining plant with desirable traits. Improvement of ornamental plant Amaryllis 'Orange Bio gamma' was carried out by exposing bulbs with gamma rays at dose 0, 10, 15, 20, 25, 30, 40 and 50 Gy using Bio Beam GM8000 gamma irradiation chamber at the Malaysian Nuclear Agency. Effect of radiation on the growth of bulbs was observed. Data on shoot and root length was recorded after 6 weeks. From the observation, the increasing dose has caused a reduction in shoot length and inhibited the root production. This paper will discuss the effects of acute gamma irradiation on the plant morphology. The result and observation obtained is useful for future work on lily improvement and will be included into Bio Beam GM8000 irradiation database. (author)

  3. A {beta} - {gamma} coincidence; Metodo de coincidencias {beta} - {gamma}

    Energy Technology Data Exchange (ETDEWEB)

    Agullo, F

    1960-07-01

    A {beta} - {gamma} coincidence method for absolute counting is given. The fundamental principles are revised and the experimental part is detailed. The results from {sup 1}98 Au irradiated in the JEN 1 Swimming pool reactor are given. The maximal accuracy is 1 per cent. (Author) 11 refs.

  4. QCD and $\\gamma\\,\\gamma$ studies at FCC-ee

    CERN Document Server

    Skands, Peter

    2016-10-20

    The Future Circular Collider (FCC) is a post-LHC project aiming at searches for physics beyond the SM in a new 80--100~km tunnel at CERN. Running in its first phase as a very-high-luminosity electron-positron collider (FCC-ee), it will provide unique possibilities for indirect searches of new phenomena through high-precision tests of the SM. In addition, by collecting tens of ab$^{-1}$ integrated luminosity in the range of center-of-mass energies $\\sqrt{s}$~=90--350~GeV, the FCC-ee also offers unique physics opportunities for precise measurements of QCD phenomena and of photon-photon collisions through, literally, billions of hadronic final states as well as unprecedented large fluxes of quasireal $\\gamma$'s radiated from the $\\rm e^+e^-$ beams. We succinctly summarize the FCC-ee perspectives for high-precision extractions of the QCD coupling, for detailed analyses of parton radiation and fragmentation, and for SM and BSM studies through $\\gamma\\gamma$ collisions.

  5. Formulation of the relationship between indices of neutron-gamma and gamma-gamma method and the percentrage of iron

    International Nuclear Information System (INIS)

    Majorowicz, J.

    1973-01-01

    In this article, the author presents the possibility of a complex utilization of radiometric logging methods, neutron-gamma profiling and gamma-gamma density logging for determining percentage of iron and establishing geophysical possibilities of identifying zones of economically profitable ores in borehole profiles. Figures present the correlations between indices of neutron-gamma and gamma-gamma logging methods and the percentage of iron, as well as the correlation of neutron-gamma and gamma-gamma indices for zones minerallized with iron ores. The article presents the correlational analyses of the results: the correlational coefficients are given as well as total error in determining iron content on the basis of each of the methods described. Next, a multidimensional statistical analysis is carried out on the results obtained. On the basis of the two-dimensional correlational coefficients calculated and the average standard deviation, an equation of linear regression was formulated, simultaneously involving three parameters - the indices of neutron-gamma and gamma-gamma logging and the percentage of iron. The multiple correlational coefficient obtained markedly exceeds the two-dimentional correlation coefficient (r=0.974>rsub(xz)>rsub(yz)>rsub(xy)). The given method of utilizing multidimensional statistics in borehole geophysics for identifying iron ores is an efficient one. On the basis of several relationships among independent variables which are less obvious (smaller values of correlational coefficient), it is possible to obtain a single distinct relationship involving all variables simultaneously. (author)

  6. The Gamma-ray Universe through Fermi

    Science.gov (United States)

    Thompson, David J.

    2012-01-01

    Gamma rays, the most powerful form of light, reveal extreme conditions in the Universe. The Fermi Gamma-ray Space Telescope and its smaller cousin AGILE have been exploring the gamma-ray sky for several years, enabling a search for powerful transients like gamma-ray bursts, novae, solar flares, and flaring active galactic nuclei, as well as long-term studies including pulsars, binary systems, supernova remnants, and searches for predicted sources of gamma rays such as dark matter annihilation. Some results include a stringent limit on Lorentz invariance derived from a gamma-ray burst, unexpected gamma-ray variability from the Crab Nebula, a huge ga.nuna-ray structure associated with the center of our galaxy, surprising behavior from some gamma-ray binary systems, and a possible constraint on some WIMP models for dark matter.

  7. Cobalt-60 gamma irradiation of shrimp

    International Nuclear Information System (INIS)

    Sullivan, N.L.B.

    1993-01-01

    Meta- and ortho-tyrosine were measured using high performance liquid chromatography (HPLC) in conjunction with electrochemical detection in shrimp irradiated using cobalt-60 gamma radiation in the absorbed dose range 0.8 to 6.0 kGy, in nonirradiated shrimp, and in bovine serum albumin (BSA) irradiated in dilute aqueous solution at 25.0 kGy. Ortho-tyrosine was measured in nonirradiated BSA. Para-, meta-, and ortho-tyrosine was measured using HPLC in conjunction with uv-absorption detection in dilute aqueous solutions of phenylalanine irradiated in the absorbed dose range 16.0 to 195.0 kGy. The measured yields of tyrosine isomers were approximately linear as a function of absorbed dose in shrimp, and in irradiated solutions of phenylalanine up to 37.0 kGy. The occurrence of meta- and ortho-tyrosine, which had formerly been considered unique radiolytic products, has not previously been reported in nonirradiated shrimp or BSA. The conventional hydrolyzation and analytical techniques used in the present study to measure meta- and ortho-tyrosine may provide the basis for a method to detect and determine the dose used in food irradiation

  8. Estudio experimental de Imaging a 100 GHz y 300 GHz para la detección de diversos objetos

    OpenAIRE

    Delgado Patiño, Héctor Kevin

    2017-01-01

    Las radiaciones cuyas longitudes de onda se sitúan en el rango de los terahertzios (THz) o décimas de terahertzio (0.1-1 THz) han despertado interés en tiempos recientes entre los investigadores dedicados al campo de las comunicaciones. Al estar situadas entre la región infrarroja y la región de microondas del espectro electromagnético, dichas radiaciones pueden propagarse con facilidad a través de materiales no polarizados, tales como la ropa o las envolturas de paquetes. Esto las hace pa...

  9. Realization of a gamma multiplicity filter and gamma multiplicity measurements

    International Nuclear Information System (INIS)

    Azgui, F.

    1981-12-01

    A gamma multiplicity filter for the study of reaction mechanism has been realised. It's composed of six NaI(Tl) counters. The flexibility of the geometry allows many configurations. This set up has been tested with gamma radioactive sources and with the 252 Cf source to resolve problems of gamma-efficiency of the NaI(Tl) counters and the contamination of neutrons in these detectors. A logical electronic unit (Encodeur) has been constructed and the around electronic has been developped. This gamma multiplicity filter has been coupled with a detector of high resolution Ge(Li), and used in two reactions: 12 C + 55 Mn at E( 12 C) = 54 MeV; α + 63 Cu at E(α) = 52 MeV. The dominant process is the fusion-evaporation. The compound nucleus 67 Ga, is formed at the same excitation energy. The values of multiplicities Msub(γ) have been extracted using a program based on the formalism of W.J. Ockels. The fractionalization of the angular momentum is well observed for some residual nuclei ( 63 Zn, 64 Zn, 65 Zn), and for each residual nucleus, the average gamma multiplicity is lower with projectile α than that with projectile 12 C. For the most strongly output channel p2n, an entry point for the 64 Zn has been determined in the reactions. All these observations are in good agreement with those published, in the same region (f-p shell) of nuclei. This set up can be coupled with different central detector as, ''X'', neutrons charged particles detectors, and will be used with the new machine SARA to make a systematic study of transfer of angular momentum to the fragments at 30 MeV/A [fr

  10. Multiple hard interactions in $\\gamma\\gamma$ and $\\gamma$p physics at LEP and HERA

    CERN Document Server

    Butterworth, J.M.; Seymour, M.H.; Storrow, J.K.; Walker, R.

    1995-01-01

    At e^+e^- and ep colliders, the large fluxes of almost on-shell photons accompanying the lepton beams lead to the photoproduction of jets. As the centre-of-mass energy is increased, regions of smaller x in the parton densities are explored and these are regions of high parton density. As a result, the probability for more than one hard partonic scattering occurring in a single \\gamma \\gamma or \\gamma p collision can become significant. This effect has been simulated using an eikonal prescription combined with the HERWIG Monte Carlo program. The possible effects of multiple hard interactions on event shapes and jet cross sections have been studied in this framework at a range of energies relevant to HERA and LEPII. The results indicate that the effects could be significant.

  11. ATLAS searches for VH, HH, VV, V+$\\gamma$/$\\gamma\\gamma$ resonances

    CERN Document Server

    AUTHOR|(INSPIRE)INSPIRE-00441490; The ATLAS collaboration

    2017-01-01

    The discovery of a Higgs boson at the Large Hadron Collider motivates searches for physics beyond the Standard Model in channels involving coupling to the Higgs boson. A search for massive resonances decaying into couples of bosons is described. The considered final states are: $HH$, $VH$, $VV$, $V\\gamma$ and $\\gamma\\gamma$ with $V$ indicating either the $W$ or the $Z$ boson. Final states with different number of leptons or photons and where, in many cases, at least one Higgs decays into a b-quark pair are studied using different jet reconstruction techniques which allow to optimize the signal acceptance for low or high Higgs boson transverse momentum. The most recent diboson resonance searches using LHC Run 2 data are described.

  12. Consequences of the factorization hypothesis in nucleon-nucleon, $\\gamma p and \\gamma \\gamma$ scattering

    CERN Document Server

    Block, Martin M

    2002-01-01

    Using an eikonal structure for the scattering amplitude, factorization theorems for nucleon-nucleon, gamma p and gamma gamma scattering at high energies have been derived, using only some very general assumptions. Using a QCD-inspired eikonal analysis of nucleon-nucleon scattering, we present here experimental confirmation for factorization of cross sections, nuclear slope parameters B and rho -values (ratio of real to imaginary portion of forward scattering amplitudes), showing that: 1) the three factorization theorems of Block and Kaidalov [2000] hold, 2) the additive quark model holds to approximately=1%, and 3) vector dominance holds to better than approximately=4%. Predictions for the total cross section, elastic cross section and other forward scattering parameters at the LHC (14 TeV) are given. (12 refs).

  13. Astronomía Gamma desde El Leoncito

    Science.gov (United States)

    Rovero, A. C.; Colombo, E.; Sahade, J.; Weekes, T. C.

    La astronomía gamma, en el extremo de energías detectadas hasta el presente, se encuentra en desarrollo en muchas partes del mundo y proporciona resultados sorprendentes a medida que la tecnología avanza en el desarrollo de nuevos detectores. La técnica Cherenkov Atmosférica es la utilizada para la detección, mediante telescopios en tierra, del efecto secundario causado por la radiación gamma de muy altas energías (E ≈ TeV). Por medio de telescopios o arreglos de detectores y utilizando la técnica mencionada, se han podido detectar algunas fuentes puntuales de mucha importancia astrofísica como la Nebulosa del Cangrejo y la galaxia de núcleo activo Markarian 421. El sistema instalado en San Juan, en cooperación con el grupo de Radiación Gamma del Observatorio Whipple, está constituído por tres colectores de 1.5m que registran pulsos de luz generados por las cascadas de partículas producidas por rayos cósmicos de todo tipo al entrar en la atmósfera terrestre. El sistema opera por barrido en ascención recta de la fuente observada que, para esta etapa del experimento, es el Centro Galáctico. Esta fuente extensa es conocida como emisor gamma de energías inferiores al TeV y ha sido observada anteriormente en este rango de energía desde el hemisferio norte pero con elevaciones bajas, situación no óptima para este tipo de técnica. Se presentan los primeros resultados del análisis de los datos obtenidos observando la región del Centro Galáctico, luego de dos años de observaciones, así como una descripción de la técnica Cherenkov Atmosférica y del equipo utilizado en la experiencia.

  14. Application of the similitude principle to gamma-gamma density measurements; Application du principe de similitude a la mesure gamma-gamma de densite

    Energy Technology Data Exchange (ETDEWEB)

    Czubek, J A [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires. Departement d' Electronique Generale, Service d' Electronique Industrielle; Institut de Recherches Nucleaires, Dep. VI, Cracow (Poland)

    1966-07-01

    The work presented here deals with the problem of the application of the similitude principle to rock density measurements by the gamma-gamma method. A formula is presented which makes it possible to transform results of gamma-gamma measurements carried out on models in order to make them suitable for comparison with results obtained under actual field conditions. Both the space coordinates and the densities are transformed. This transformation makes it possible to obtain a calibration curve as a function of the density for a gamma-gamma probe using only a single model of given density. The influence has also been studied of the chemical composition on the results obtained from gamma-gamma measurements. A method has been developed for estimating the equivalent Z parameter of the medium; the possibility of completely eliminating the influence of the chemical composition of the medium on the measurement results has been studied. (author) [French] L'etude presentee ci-dessous traite le probleme de l'application du principe de similitude aux mesures de densite des roches par la methode gamma-gamma. Nous indiquons une formule qui permet de transformer les resultats des mesures gamma-gamma effectuees sur les modeles pour les comparer aux resultats obtenus dans les conditions reelles sur le terrain. On transforme les coordonnees spatiales ainsi que les densites. Cette transformation donne la possibilite d'obtenir une courbe d'etalonnage (en fonction de la densite) pour une sonde gamma-gamma en utilisant un seul modele de densite donnee. On a etudie aussi l'influence de la composition chimique sur les resultats obtenus des mesures gamma-gamma. On a etabli une methode d'estimation du parametre Z equivalent du milieu, ainsi que la possibilite d'eliminer completement l'influence de la composition chimique du milieu sur les resultats des mesures de densite. (auteur)

  15. A simple neutron-gamma discriminating system

    International Nuclear Information System (INIS)

    Liu Zhongming; Xing Shilin; Wang Zhongmin

    1986-01-01

    A simple neutron-gamma discriminating system is described. A detector and a pulse shape discriminator are suitable for the neutron-gamma discriminating system. The influence of the constant fraction discriminator threshold energy on the neutron-gamma resolution properties is shown. The neutron-gamma timing distributions from an 241 Am-Be source, 2.5 MeV neutron beam and 14 MeV neutron beam are presented

  16. A normalisation for the four - detector system for gamma - gamma angular correlation studies

    International Nuclear Information System (INIS)

    Kiang, G.C.; Chen, C.H.; Niu, W.F.

    1994-01-01

    A normalisation method for the multiple - HPGe - detector system is described. The system consists of four coaxial HPGe detectors with a CAMAC event - by - event data acquisition system, enabling to measure six gamma -gamma coincidences of angles simultaneously. An application for gamma - gamma correlation studies of Kr 82 is presented and discussed. 3 figs., 6 refs. (author)

  17. Measurements of time differential perturbated angular gamma-gamma correlations in the /sup 207/Bi decay

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Ashok; Soni, S K; Pancholi, S K; Gupta, S L [Delhi Univ. (India). Dept. of Physics and Astrophysics

    1976-10-01

    The results are presented of measuring the differential perturbed angular ..gamma gamma..-correlations for the ..gamma.. 1063.62 - ..gamma.. 569.67 keV cascade in /sup 207/Bi. The results obtained are analyzed and compared with data of other authors.

  18. Description of Radiation Sources Installed at the French Atomic Energy Commissariat; Description de sources de rayonnement installees au commissariat a l'energie atomique; Opisanie istochnikov oblucheniya, nakhodyashchikhsya v frantsuzskom komissariate po atomnoj ehnergii; Descripcion de las fuentes de radiaciones instaladas en el commissariat a l'energie

    Energy Technology Data Exchange (ETDEWEB)

    Leveque, P

    1960-07-15

    partie de cette casemate est amenagee en chambre frigorifique ce qui permettra de faire des essais de conservation alimentaire sous rayonnement. - les canaux verticaux du reacteur EL 2 dits ''trous de chimiste''; lorsque ces canaux sont chemises avec une feuille de cadmium, le flux gamma obtenu passe de 100 000 a 200 000 r/h mais ils ne peuvent servir qu'a l'irradiation de matieres organiques car il y a activation de la plupart des produits mis a irradier par le flux epithermique et rapide. L'auteur decrit ensuite le dispositif du Centre Lyonnais d'Applications atomiques, cree pres de Lyon par un groupe d'industriels. Cette installation, dont la mise en service est prevue pour le debut de 1960, aura un caractere semi-industriel (source de cobalt-60 de 3 000 dans un premier stade, puis de 40 000 curies) et permettra d'effectuer des irradiations en continu. (author) [Spanish] El autor describe en primer lugar cuatro instalaciones que se encuentran en el Centro de Estudios Nucleares de Saclay: - una fuente de {sup 60}Co de 600 curies, para laboratorio; el dispositivo utilizado es sencillo y seguro, pero no permite modificar a voluntad la intensidad del flujo de rayos gamma; - un conjunto de 7 fuentes de {sup 60}Co (de las cuales la mas potente tiene 1 000 curies) instalado en una casamata de hormigon; un dispositivo neumatico permite colocar en posicion de trabajo la fuente o las fuentes necesarias; - una casamata con capacidad suficiente para recibir 100 barras de combustible procedentes del nuevo reactor EL-3; un sector de esta casamata esta acondicionado como camara frigorifica, lo que permitira llevar a cabo ensayos sobre la conservacion de alimentos por irradiacion; - los canales verticales del reactor EL-2 denominados ''orificios para usos quimicos'''; cuando estos canales se revisten interiormente con laminas de cadmio, la intensidad del flujo de rayos gamma aumenta de 100 000 a 200 000 roentgens/hora , pero solo puede utilizarse para la irradiacion de sustancias

  19. Tejido óseo y apósito biológico esterilizados con gas óxido de etileno Tesis presentada en opción al grado científico Doctor en Ciencias Médicas

    OpenAIRE

    Jacas Torné, Manuel

    2014-01-01

    Introducción: En Cuba tradicionalmente se ha empleado las radiaciones Gamma para esterilizar el tejido óseo y la piel porcina. Con el propósito de buscar una alternativa a su empleo se estudió el gas óxido de etileno (OtE), nunca antes empleado en Cuba con esos fines. Objetivo general: Evaluar la efectividad del gas óxido de etileno como método esterilizante del tejido óseo esponjoso y la piel porcina. Metodología de la investigación: Se realizó un estudio experimental In Vitro d...

  20. Attrition resistant gamma-alumina catalyst support

    Science.gov (United States)

    Singleton, Alan H.; Oukaci, Rachid; Goodwin, James G.

    2006-03-14

    A .gamma.-alumina catalyst support having improved attrition resistance produced by a method comprising the steps of treating a particulate .gamma.-alumina material with an acidic aqueous solution comprising water and nitric acid and then, prior to adding any catalytic material thereto, calcining the treated .gamma.-alumina.

  1. Gamma-Ray Interactions for Reachback Analysts

    Energy Technology Data Exchange (ETDEWEB)

    Karpius, Peter Joseph [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Myers, Steven Charles [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-08-02

    This presentation is a part of the DHS LSS spectroscopy training course and presents an overview of the following concepts: identification and measurement of gamma rays; use of gamma counts and energies in research. Understanding the basic physics of how gamma rays interact with matter can clarify how certain features in a spectrum were produced.

  2. Multifrequency Observations of Gamma-Ray Burst

    OpenAIRE

    Greiner, J.

    1995-01-01

    Neither a flaring nor a quiescent counterpart to a gamma-ray burst has yet been convincingly identified at any wavelength region. The present status of the search for counterparts of classical gamma-ray bursts is given. Particular emphasis is put on the search for flaring counterparts, i.e. emission during or shortly after the gamma-ray emission.

  3. Stellar Sources of Gamma-ray Bursts

    OpenAIRE

    Luchkov, B. I.

    2011-01-01

    Correlation analysis of Swift gamma-ray burst coordinates and nearby star locations (catalog Gliese) reveals 4 coincidences with good angular accuracy. The random probability is 4\\times 10^{-5}, so evidencing that coincident stars are indeed gamma-ray burst sources. Some additional search of stellar gamma-ray bursts is discussed.

  4. Application of nuclear gamma methods in mining

    International Nuclear Information System (INIS)

    Simon, L.; Bosak, J.

    1980-01-01

    A brief review is presented of basic physical characteristics of laboratory, field and operating gamma methods, of their classifications and principles. The measuring instrumentation used and the current state of applications of nuclear gamma methods in coal and ore mining and related branches are described in detail. Principles and practical recommendations are given for safety at work when handling gamma sources. (B.S.)

  5. Energy spectrum of lightning gamma emission

    Energy Technology Data Exchange (ETDEWEB)

    Chubenko, A.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Karashtin, A.N. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Ryabov, V.A., E-mail: ryabov@x4u.lebedev.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shepetov, A.L. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Antonova, V.P.; Kryukov, S.V. [Ionosphere Institute, Almaty (Kazakhstan); Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Ptitsyn, M.O., E-mail: ptitsyn@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shalamova, S.Ya. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Shlyugaev, Yu.V. [Research Radiophysics Institute, Nizhny Novgorod (Russian Federation); Vildanova, L.I. [Tien-Shan Mountain Cosmic Ray Station, Almaty (Kazakhstan); Zybin, K.P. [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation); Gurevich, A.V., E-mail: alex@lpi.r [P.N. Lebedev Physical Institute of RAS, Moscow (Russian Federation)

    2009-08-10

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10{sup -3}-10{sup -2} J. The experimental results are in an agreement with the runaway breakdown mechanism.

  6. Energy spectrum of lightning gamma emission

    International Nuclear Information System (INIS)

    Chubenko, A.P.; Karashtin, A.N.; Ryabov, V.A.; Shepetov, A.L.; Antonova, V.P.; Kryukov, S.V.; Mitko, G.G.; Naumov, A.S.; Pavljuchenko, L.V.; Ptitsyn, M.O.; Shalamova, S.Ya.; Shlyugaev, Yu.V.; Vildanova, L.I.; Zybin, K.P.; Gurevich, A.V.

    2009-01-01

    The results of gamma emission observations obtained during thunderstorms at Tien-Shan Mountain Cosmic Ray Station are presented. The energy spectrum radiation of the stepped leader gamma radiation is measured. The total energy of stepped leader emitted in gamma rays is estimated as 10 -3 -10 -2 J. The experimental results are in an agreement with the runaway breakdown mechanism.

  7. Gamma spectrometry of infinite 4Π geometry

    International Nuclear Information System (INIS)

    Nordemann, D.J.R.

    1987-07-01

    Owing to the weak absorption og gamma radiation by matter, gamma-ray spectrometry may be applied to samples of great volume. A very interesting case is that of the gamma-ray spectrometry applied with 4Π geometry around the detector on a sample assumed to be of infinite extension. The determination of suitable efficiencies allows this method to be quantitative. (author) [pt

  8. Gamma-rays from deep inelastic collisions

    International Nuclear Information System (INIS)

    Stephens, F.S.

    1981-01-01

    My objective in this talk is to consider the question: 'What can be learned about deep inelastic collisions (DIC) from studying the associated gamma-rays'. First, I discuss the origin and nature of the gamma-rays from DIC, then the kinds of information gamma-ray spectra contain, and finally come to the combination of these two subjects. (orig./HSI)

  9. Gamma irradiation of cholestenone oximes

    International Nuclear Information System (INIS)

    Uenseren, Envare.

    1976-01-01

    Irradiation of cholest-4-en-3-one and cholest-5-en-3-one oximes with cobalt-60 gamma-rays in different solvents at different doses gave a mixture of products from which ketones corresponding to the starting oximes, Beckmann type rearrangement products, and some other radiolysis products have been isolated and identified

  10. Gamma scanner conceptual design report

    International Nuclear Information System (INIS)

    Swinth, K.L.

    1979-11-01

    The Fuels and Materials Examination Facility (FMEF) will include several stations for the nondestructive examination of irradiated fuels. One of these stations will be the gamma scanner which will be employed to detect gamma radiation from the irradiated fuel pins. The conceptual design of the gamma scan station is described. The gamma scanner will use a Standard Exam Stage (SES) as a positioner and transport mechanism for the fuel pins which it will obtain from a magazine. A pin guide mechanism mounted on the face of the collimator will assure that the fuel pins remain in front of the collimator during scanning. The collimator has remotely adjustable tungsten slits and can be manually rotated to align the slit at various angles. A shielded detector cart located in the operating corridor holds an intrinsic germanium detector and associated sodium-iodide anticoincidence detector. The electronics associated with the counting system consist of standard NIM modules to process the detector signals and a stand-alone multichannel analyzer (MCA) for counting data accumulation. Data from the MCA are bussed to the station computer for analysis and storage on magnetic tape. The station computer controls the collimator, the MCA, a source positioner and the SES through CAMAC-based interface hardware. Most of the electronic hardware is commercially available but some interfaces will require development. Conceptual drawings are included for mechanical hardware that must be designed and fabricated

  11. Concrete for. gamma. radiation shielding

    Energy Technology Data Exchange (ETDEWEB)

    de Azevedo e Souza, A.C. (Rio de Janeiro Univ. (Brazil). Inst. de Quimica); Rogers, J D [Rio de Janeiro Univ. (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia

    1980-06-01

    The attenuation characteristics of ..gamma.. radiation in concrete slabs, considering their mechanical resistence and densities were determined. One heavy concrete which was used, was prepared using as additives iron ore and Fe/sub 2/ O/sub 3/ pellets in various grain sizes. Fortran programs were used for analysing data and determining the absorption coefficients and attenuation factors.

  12. Gamma and X 93 spectrometry

    International Nuclear Information System (INIS)

    1994-05-01

    The Meetings of Gamma and X 93 Spectrometry were held on 12-14 October 1993. The symposium was organized into six sessions: Instrumentation development, Nuclear matter measurement, Method and calibration, Medical applications, Environment survey (radioactive traces measurement), other applications (spent fuels analysis, various techniques). Separate abstracts were prepared for all the papers in this volume. (TEC)

  13. Effects of gamma radiation ({sup 60}Co) on the main physical and chemical properties of health care packaging and their compounds paper and multilayer plastic film, used for health products sterilization; Efeitos da radiacao gama (Cobalto-60) nas principais propriedades fisicas e quimicas da embalagens compostas por papel grau cirurgico e filme plastico laminado, destinadas a esterilizacao de produtos para saude

    Energy Technology Data Exchange (ETDEWEB)

    Porto, Karina Meschini Batista Geribello

    2013-07-01

    Gamma radiation is one of the technologies applied for the sterilization of packaging systems containing products for health. During sterilization process it is critical that the properties of packages are maintained. In this study two samples of commercial pouch packaging comprised of surgical grade paper on one side and the other side multilayer plastic film were irradiated with gamma rays. The following doses were applied 25 kGy (1,57 kGy/h) and 50 kGy (1,48 kGy/h). One packaging sample was paper formed by softwood fibers and multilayer plastic film based on poly(ethylene terephthalate) (PET)/polyethylene (PE). The second type of paper sample was made by a mixture of softwood and hardwood fibers and multilayer plastic film based on polyethylene terephthalate (ethylene) (PET)/polypropylene (PP). The effects of radiation on the physical and chemical properties of papers and multilayer plastic films, as well as the properties of the package were studied. The paper was the more radiation sensitive among the studied materials and radiation effects were more pronounced at brightness, pH, tearing resistance, bursting strength and tensile strength. Nonetheless, worst comparatively effects were noted on the sample made by a mixture of softwood and hardwood fibers. The porosity of paper was enhanced by 50 kGy. In the case of plastic films, radiation effects on tensile strength was the most pronounced property for both samples. In the case of the packaging the sealing resistance decreased with radiation. The effects observed for the treatment at 50 kGy were more pronounced when compared to 25 kGy. This last is the dose which is usually applied to sterilize health products. A dosimetry study was performed during irradiation at 25 kGy, 40 kGy and 50 kGy and its importance may be reported by the average dose variation 20 %. (author)

  14. Isolation of novel para-pentyl phenyl benzoate from Mondia whitei ...

    African Journals Online (AJOL)

    Results: The structure of the compound was elucidated as para pentyl phenyl benzoate. The neuropharmacological evaluation of the compound indicated significant (p<0.05) depression of the central nervous system. The binding characteristics of the compound to gamma amino butyric acid A receptors appears to be more ...

  15. Low level GAMMA0 spectrometry by beta-gamma coincidence

    International Nuclear Information System (INIS)

    Grigorescu, E.L.; Luca, A.; Razdolescu, A.C.; Ivan, C.

    1999-01-01

    Low level gamma spectrometry has a wide application, especially in environmental monitoring. Two variants, based on a beta-gamma coincidence technique, were studied. The equipment was composed of a beta detector and a Ge(Li) gamma detector (6% - relative efficiency), with the associated electronics. The gamma rays are recorded by the multichannel analyzer (4096 channels) only if the associated beta particles, which precede the gamma transitions, are registered in coincidence. Two types of beta detectors were used: plastic and liquid scintillators. In both cases, an external lead shield of 5 cm thick was used. The integral gamma background (50-1700 KeV) was reduced about 85 and 50 times, respectively. The corresponding MDA (Minimum Detectable Activity) values decreased about 1.5 and (3-7) times, respectively. The 2π sr plastic beta detector was placed on top the Ge(Li). The sample was inserted between the two detectors. The measurement time was 10 4 s. A 4π sr detector, built of the same material, was also studied, but it proved to be less advantageous because the background was reduced only 16 times; for a MDA reduction similar with that of the 2π sr variant, a longer measurement was needed (3.10 4 s). The other type of beta detector used, was a liquid scintillator. The dissolving of the samples in scintillator ensures a 4π sr measurement geometry. The vials with scintillator (10 ml volume) were placed on top the Ge(Li) and visualised by the photocathode of a phototube. This setup was surrounded by an enclosure which prevent the light penetration. The measurement time was 10 4 s. The only difficulty encountered in this low level measurement method is the accurate determination of the beta efficiency. A limitation is the possibility to measure only small mass samples. These variants are more simple and cheaper than others, previously studied. The advantage of the method is obvious when, instead of low MDA values, shorter measurement times are preferred. The

  16. Calculation of absorbed dose for skin contamination imparted by beta radiation through the VARSKIN modified code for 122 interesting isotopes for nuclear medicine, nuclear power plants and research; Calculo de dosis absorbida para contaminacion en piel impartida por radiacion beta mediante el codigo VARSKIN modificado para 122 isotopos de interes para medicina nuclear, plantas nucleares e investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T [Depto. de Metrologia, ININ, 52045 Ocoyoacac, Estado de Mexico (Mexico)

    1991-07-01

    In this work the implementation of a modification of the VARSKIN code for calculation of absorbed dose for contamination in skin imparted by external radiation fields generated by Beta emitting is presented. The modification consists on the inclusion of 47 isotopes of interest even Nuclear Plants for the dose evaluation in skin generated by 'hot particles'. The approach for to add these isotopes is the correlation parameter F and the average energy of the Beta particle, with relationship to those 75 isotopes of the original code. The methodology of the dose calculation of the VARSKIN code is based on the interpolation, (and integration of the interest geometries: punctual or plane sources), of the distribution functions scaled doses in water for beta and electrons punctual sources, tabulated by Berger. Finally a brief discussion of the results for their interpretation and use with purposes of radiological protection (dose insurance in relation to the considered biological effects) is presented.

  17. Calculation of the absorbed dose for contamination in skin imparted by beta radiation through the Varskin code modified for 122 isotopes of interest for nuclear medicine, nuclear plants and research; Calculo de dosis absorbida para contaminacion en piel impartida por radiacion beta mediante el codigo Varskin modificado para 122 isotopos de interes para medicina nuclear, plantas nucleares e investigacion

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez R, J T

    1992-06-15

    In this work the implementation of a modification of the Varskin code for calculation of absorbed dose by contamination in skin imparted by external radiation fields generated by beta emitting is presented. The necessary data for the execution of the code are: isotope, dose depth, isotope activity, geometry type, source radio and time of integration of the isotope, being able to execute combinations of up to five radionuclides. This program it was implemented in Fortran 5 by means of the FFSKIN source program and the executable one in binary language BFFSKIN being the maximum execution time of 5 minutes. (Author)

  18. Oro para Colombia

    OpenAIRE

    Rubio Forero, María Claudia

    2016-01-01

    Las mujeres han debido atravesar un largo camino partiendo de la discriminación hasta empezar un proceso de equidad en la sociedad y en el deporte, de esta manera llegar a ser parte de un evento como los Juegos Olímpicos. Esta tesis toma el caso de tres atletas colombianas y describe su proceso de formación para lograr dos medallas de oro para el país.

  19. Increase in neutrophil Fc gamma receptor I expression following interferon gamma treatment in rheumatoid arthritis.

    Science.gov (United States)

    Goulding, N J; Knight, S M; Godolphin, J L; Guyre, P M

    1992-04-01

    The therapeutic potential of interferon gamma (IFN gamma) in a number of disease states is still being explored, but progress is hampered by the lack of a suitable measure of in vivo biological activity. To assess the in vivo biological effects of recombinant human IFN gamma (rhIFN gamma), 14 patients were studied in a randomised, prospective, double blind, placebo controlled trial of this cytokine for the treatment of rheumatoid arthritis. The levels of Fc gamma receptors on peripheral blood neutrophils were measured at baseline and after 21 days of once daily, subcutaneous injections of rhIFN gamma or placebo. An induction of neutrophil Fc gamma receptor type I (Fc gamma RI) was seen in the group of patients receiving recombinant human rhIFN gamma but not in those receiving placebo. No change in the expression of Fc gamma RII or Fc gamma RIII was detected. The amount of induction of Fc gamma RI detected on the neutrophils of patients receiving rhIFN gamma did not correlate with clinical measures of response at either 21 days or at the end of the study (24 weeks). No significant clinical responses were observed in the rhIFN gamma group at these times. These data confirm that the reported in vitro effect of IFN gamma on human neutrophil Fc receptor expression can be reproduced in vivo.

  20. Study of {gamma}'s in Naiade; Etude des gamma de Naiade

    Energy Technology Data Exchange (ETDEWEB)

    Millot, J P; Rastoin, J [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1958-07-01

    Following a study of the gamma sources, the flux of gamma of different energies in the swimming pool is investigated. The biological dose can thus be obtained by calculation, and compared with the results given by photographic plates. The influence of photoneutrons is estimated by calculation, and research is being carried out on their influence on the thermal neutron flux curve on the axis of the uranium plate, with the plate emitting neutrons and with the plate protected by boral. (author) [French] Apres l'etude des sources de gamma, l'on etudie le flux de gamma de differentes energies dans la piscine. La dose biologique peut etre obtenue ainsi par le calcul et comparee avec les resultats donnes par les plaques photographiques. L'influence des photoneutrons est estimee par le calcul et l'on recherche leur influence sur la courbe de flux de neutrons thermiques sur l'axe de la plaque d'uranium, la plaque emettant des neutrons et la plaque protegee par du boral. (auteur)

  1. Relativistic motion in gamma-ray bursts

    International Nuclear Information System (INIS)

    Krolik, J.H.; Pier, E.A.

    1991-01-01

    Three fundamental problems affect models of gamma-ray bursts, i.e., the energy source, the ability of high-energy photons to escape the radiation region, and the comparative weakness of X-ray emission. It is indicated that relativistic bulk motion of the gamma-ray-emitting plasma generically provides a solution to all three of these problems. Results show that, if the plasma that produces gamma-ray bursts has a bulk relativistic velocity with Lorentz factor gamma of about 10, several of the most troubling problems having to do with gamma-ray bursts are solved. 42 refs

  2. Simultaneous neutron and gamma spectrum adjustment

    International Nuclear Information System (INIS)

    Remec, I.

    1996-01-01

    The spectrum adjustment procedure was extended to simultaneous neutron and gamma spectrum adjustment, and the feasibility of this technique is demonstrated in the analysis of HFIR dosimetry experiments. Conditions in which gamma rays may contribute considerably to radiation damage in steels are discussed. Beryllium helium accumulation fluence monitors (HAFMs) were found to be good monitors in gamma fields of intensities high enough to contribute to steel embrittlement. Use of 237 Np, 238 U, and 9 Be HAFM as gamma dosimeters is proposed for high-dose irradiations in high-energy, high-intensity gamma fields

  3. Inverse Compton gamma-rays from pulsars

    International Nuclear Information System (INIS)

    Morini, M.

    1983-01-01

    A model is proposed for pulsar optical and gamma-ray emission where relativistic electrons beams: (i) scatter the blackbody photons from the polar cap surface giving inverse Compton gamma-rays and (ii) produce synchrotron optical photons in the light cylinder region which are then inverse Compton scattered giving other gamma-rays. The model is applied to the Vela pulsar, explaining the first gamma-ray pulse by inverse Compton scattering of synchrotron photons near the light cylinder and the second gamma-ray pulse partly by inverse Compton scattering of synchrotron photons and partly by inverse Compton scattering of the thermal blackbody photons near the star surface. (author)

  4. Estrategias para negociaciones exitosas.

    Directory of Open Access Journals (Sweden)

    José B. Parra V

    2010-01-01

    Full Text Available Las estrategias de negociación son herramientas para disminuir conflictos o para intercambiar bienes y servicios. Una negociación exitosa crea relaciones de solidaridad y propicia reciprocidad, cooperación y confianza para quienes tendrán relaciones permanentes de negociación con beneficios para ambas partes. Una estrategia de negociación exitosa requiere manejar el desarrollo del ambiente social del grupo de personas, con la finalidad de tener presente las fronteras que no pueden irrumpirse. Otro aspecto importante, es el lenguaje corporal utilizado por las personas y las tácticas que se practican. El manejo de esta información permite diseñar diferentes modelos de negociaciones para cada caso específico. Este documento propone la utilización de la herramienta MONACO, diseñada por los autores, que es un software útil para encontrar los mejores tácticas posibles dentro de una negociación; basándose en el lenguaje corporal que muestra el negociante oponente durante cada oferta monetaria. El uso de este software da al negociador la oportunidad de manejar las negociaciones con mayor control, el negociador que usa el software puede elegir una estrategia de acuerdo a las relaciones que espera mantener con el negociador oponente.

  5. Multidimensional Gamma-Ray Spectrometry and its Use in Biology; La Spectrometry Gamma Multidimensionnelle et son Application en Biologie; Mnogomernaya spektrometriya gamma-luchej i ee ispol'zovanie v biologii; La Espectrometria Gamma Multidimensional y su Empleo en Biologia

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, J. M.; Kornberg, H. A. [Battelle Memorial Institute, Pacific Northwest Laboratory, Richland, WA (United States)

    1965-10-15

    rodeando dichos detectores conotro detector anular de anticoincidencias (un cristal de NaI(Tl) de 11 Vulgar-Fraction-One-Half pulg de espesor, con un diametro interior de 6 Vulgar-Fraction-One-Half pulg). Un analizador multidimensional de 4096 canales mide en coincidencia los dos rayos gamma segfin su energia y almacena los datos en el piano de la memoria de 64 x 64 canales, en tanto que las fisiones no coincidentes se almacenan solo en los ejes de dicha memoria. Esto reduce eficazmente la actividad de fondo y la interferencia debida al efecto Compton en varios ordenes de magnitud y mejora considerablemente la selectividad. La medicion directa por espectrometria gamma de los radionficlidos presentes como vestigios en muestras biolfigicas se ha visto obstaculizada por la presencia de cantidades relativamente grandes de {sup 40}K natural, cuya radiacifin gamma de 1,41 MeV dificulta esas mediciones. Como la mayorfa de los radionuclidos se desintegran por emision de dos o mas rayos gamma en cascada, la nueva tecnica permite una medicion selectiva directa y su campo de aplicacion es mas amplio. Por ejemplo, permite medir facilmente el {sup 22}Na (radionflclido natural producido por accion de los rayos cosmicos), el {sup 134}Cs y el {sup 137}Cs (productos de fision) a los niveles (en algunos casos de 1 desint/minx kg) en que se hallan presentes en la carne, en el pescado, en otros productos alimenticios y en la orina, haciendo posible los estudios sobre la relacion absorcion-excrecion. Esta tecnica podrfa aplicarse a los estudios con indicadores y serfa de especial utilidad para la medicion simultanea de la absorcion, el deposito y la renovacion en el cuerpo de diversos compuestos adecuadamente marcados; combinada con el analisis por activacion neutronica, permite realizar mediciones de muchos elementos presentes en los tejidos y en la sangre en cantidades del orden de algunas partes por 10{sup -9}. (author) [Russian] Mnogomernaja spektrometrija gamma-luchej javljaetsja novym

  6. BFKL resummation effects in gamma* gamma* to rho rho

    Energy Technology Data Exchange (ETDEWEB)

    Enberg, R.; Pire, B.; Szymanowski, L.; Wallon, S.

    2005-08-11

    We calculate the leading order BFKL amplitude for the exclusive diffractive process {gamma}*{sub L}(Q{sub 1}{sup 2}) {gamma}*{sub L}(Q{sub 2}{sup 2}) {yields} {rho}{sub L}{sup 0}{rho}{sub L}{sup 0} in the forward direction, which can be studied in future high energy e{sup +}e{sup -} linear colliders. The resummation effects are very large compared to the fixed-order calculation. We also estimate the next-to-leading logarithmic corrections to the amplitude by using a specific resummation of higher order effects and find a substantial growth with energy, but smaller than in the leading logarithmic approximation.

  7. Urban gamma spectrometry. Report 2

    Energy Technology Data Exchange (ETDEWEB)

    Aage, H.K. (Technical Univ. of Denmark, Kgs. Lyngby (Denmark)); Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H. (Radiation and Nuclear Safety Authority, Helsinki (Finland))

    2009-06-15

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather

  8. Urban gamma spectrometry. Report 2

    International Nuclear Information System (INIS)

    Aage, H.K.; Kuukankorpi, S.; Moring, M.; Smolander, P.; Toivonen, H.

    2009-06-01

    Urban gamma spectrometry has been given only minor attention with the focus being on rural gamma spectrometry. However, in recent years the Nordic emergency management authorities have turned focus towards border control and lost or stolen sources. Gamma spectra measured in urban areas are characterized by a wide variety of spectrum shapes and very fast changes in environmental background. In 2004 a Danish CGS (Carborne Gamma Spectrometry) survey took place in Copenhagen. It was found that gamma spectrometry in urban areas is far more complicated to interpret than had previously been thought and a new method 'Fitting with Spectral Components', FSC, based on NASVD, was tested with some success. In Finland, a database 'LINSSI' has been developed for spectral data management. In CGS search mode a 'peak hypothesis test' is applied to the measured spectra. This system was tested during the Helsinki 2005 Athletics World Championship and it provides fast and reliable automated alarms for intermediate and high level signals. In Sweden mobile detector systems are used for border controls and problems are encountered when making measurement in harbour, container areas. The methods for handling data and for interpretation of urban gamma spectrometry measurements were compared and tested on the same data sets from Copenhagen and Helsinki. Software tools were developed for converting data between the Finnish LINSSI database and the binary file formats used in Denmark and Sweden. The Processing methods used at DTU and STUK have different goals. The ASSS and FSC methods are designed to optimize the overall detection capability of the system, while sacrificing speed, usability and to a certain level robustness. These methods cannot always be used for real time analysis. The Peak Significance method is designed to give robust alarms in real time, while sacrificing some of the detection capability. Thus these methods are not interchangeable, but rather complementary. An ideal system

  9. Determination of gamma production from (n, gamma) reactions

    International Nuclear Information System (INIS)

    Kostal, M.

    2007-06-01

    Calculation of gamma production by interaction of neutrons with materials requires a reasonable accuracy of the nuclear libraries, i. e. effective cross sections, nuclear levels and probabilities of transitions between them. Accurate data enable accurate calculations to be performed, e.g. for PGNAA. First, gamma production in a thick 56 Fe target was examined. Appreciable discrepancies were found among the nuclear libraries available. Additional calculations were performed and compared with the observed data. The fluence of photons observed behind a thick iron target was investigated, the target being irradiated with neutrons from the front side. The results were evaluated for the various nuclear libraries. It is concluded that the libraries ENDF/B VI.2., i.e. data embedded in the MCNPX code, are sufficient f