WorldWideScience

Sample records for quartz optical fibres

  1. Fibre-Optic Gyroscope

    Directory of Open Access Journals (Sweden)

    V. N. Saxena

    1983-04-01

    Full Text Available Comparative study of mechanical, ring-laser and fibre-optic gyroscopes has been made. The single mode fibre-optic gyroscope having a large number of turns of the optical fibre in the spool, replacing He-Ne gas laser by a GaAs laser diode, there by reducing the noise level, and using fully integrated fibre-optics, works out to be the best in the final analysis, for safe navigation and homing of the guided missiles.

  2. Optical fibres

    CERN Document Server

    Geisler, J; Boutruche, J P

    1986-01-01

    Optical Fibers covers numerous research works on the significant advances in optical fibers, with particular emphasis on their application.This text is composed of three parts encompassing 15 chapters. The first part deals with the manufacture of optical fibers and the materials used in their production. The second part describes optical-fiber connectors, terminals and branches. The third part is concerned with the major optoelectronic components encountered in optical-communication systems.This book will be of value to research scientists, engineers, and patent workers.

  3. Microstructured polymer optical fibres

    CERN Document Server

    Large, Maryanne; Barton, Geoff; van Eijkelenborg, Martijn A

    2008-01-01

    Microstructured Polymer Optical Fibres describes the optical properties of microstructured fibres, how they are made and modelled, and outlines some potential applications. These applications include areas where polymer fibres are already used, such as high-data rate transmission for Fibre-to-the Home or within cars, as well as completely new areas such as the photonic bandgap transmission of ""difficult"" wavelengths. Emphasising a conceptual understanding of the underlying physics, Microstructured Polymer Optical Fibres is clearly written, and includes numerous illustrations. It provides an

  4. POLARISATION PRESERVING OPTICAL FIBRE

    DEFF Research Database (Denmark)

    2000-01-01

    . This cladding structure provides polarisation preserving properties to the optical fibre. Optical fibres using this technology may have claddings with elements placed non-periodically as well as in a two-dimensional periodic lattice - such as cladding providing Photonic Band Gap (PBG) effects....

  5. Fibre-optical microendoscopy.

    Science.gov (United States)

    Gu, M; Bao, H; Kang, H

    2014-04-01

    Microendoscopy has been an essential tool in exploring micro/nano mechanisms in vivo due to high-quality imaging performance, compact size and flexible movement. The investigations into optical fibres, micro-scanners and miniature lens have boosted efficiencies of remote light delivery to sample site and signal collection. Given the light interaction with materials in the fluorescence imaging regime, this paper reviews two classes of compact microendoscopy based on a single fibre: linear optical microendoscopy and nonlinear optical microendoscopy. Due to the fact that fluorescence occurs only in the focal volume, nonlinear optical microendoscopy can provide stronger optical sectioning ability than linear optical microendoscopy, and is a good candidate for deep tissue imaging. Moreover, one-photon excited fluorescence microendoscopy as the linear optical microendoscopy suffers from severe photobleaching owing to the linear dependence of photobleaching rate on excitation laser power. On the contrary, nonlinear optical microendoscopy, including two-photon excited fluorescence microendoscopy and second harmonic generation microendoscopy, has the capability to minimize or avoid the photobleaching effect at a high excitation power and generate high image contrast. The combination of various nonlinear signals gained by the nonlinear optical microendoscopy provides a comprehensive insight into biophenomena in internal organs. Fibre-optical microendoscopy overcomes physical limitations of traditional microscopy and opens up a new path to achieve early cancer diagnosis and microsurgery in a minimally invasive and localized manner.

  6. Optical Fibre Bundle

    CERN Multimedia

    These are sample fibre optic cables which are used for networking. Optical fibers are widely used in fiber-optic communications, where they permit transmission over longer distances and at higher bandwidths (data rates) than wire cables. Fibers are used instead of metal wires because signals travel along them with less loss and are also immune to electromagnetic interference. This is useful for somewhere like CERN where magnets with their highly powerful magnetic fields could pose a problem.

  7. Optical fibre line failure detecting

    OpenAIRE

    Xie, Feng

    2013-01-01

    With the development of modern communications, in order to meet the needs of social development and technological progress the optical fibre communications has become the main communication medium for its high reliability and security. Fibre-optic cable is the channel for signal transmission. It is an important component in the entire fibre-optic network. Once the fibre-optic cable fault happened, the entire communication system would be impacted seriously. When fault occurs, it is important ...

  8. Fibre Optics in Undersea Applications

    Directory of Open Access Journals (Sweden)

    A. K. Talwar

    1984-01-01

    Full Text Available Role of optical fibres for underwater communication cables and hydrophones is discussed. The fibre optics cables provide an excellent solution to the historical bandwidth-diameter problems of conventional coaxial cables.Fibre optic hydrophones are found to have many more advantages apart from high sensitivity and large dynamic range, over the classical sound sensors used in underwater work.

  9. The CMS forward calorimeter with quartz fibres

    CERN Multimedia

    Laurent Guiraud

    1999-01-01

    Part of the forward hadron calorimeter for the CMS experiment at the LHC is seen here. The calorimeter will be placed at the ends of the experiment barrel to measure the energy of particles produced in the 14 TeV proton-proton collisions. In consists of an iron absorber and specially designed radiation-hard quartz so that it survives the high radiation levels produced by collisions.

  10. Single-mode optical fibres

    CERN Document Server

    Cancellieri, G

    1991-01-01

    This book describes signal propagation in single-mode optical fibres for telecommunication applications. Such description is based on the analysis of field propagation, considering waveguide properties and also some of the particular characteristics of the material fibre. The book covers such recent advances as, coherent transmissions; optical amplification; MIR fibres; polarization maintaining; polarization diversity and photon counting.

  11. Microstructured Optical Fibres

    DEFF Research Database (Denmark)

    1999-01-01

    complete PBGs, which reflects light incident from air or vacuum. Such structures may be used as cladding structures in optical fibres, where light is confined and thereby guided in a hollow core region. In addition, the present invention relates to designs for ultra low-loss PBG waveguiding structures......The present invention relates to a new class of optical waveguides, in which waveguiding along one or more core regions is obtained through the application of the Photonic Bandgap (PBG) effect. The invention further relates to optimised two-dimensional lattice structures capable of providing...

  12. Extreme Silica Optical Fibre Gratings

    Directory of Open Access Journals (Sweden)

    Kevin Cook

    2008-10-01

    Full Text Available A regenerated optical fibre Bragg grating that survives temperature cycling up to 1,295°C is demonstrated. A model based on seeded crystallisation or amorphisation is proposed.

  13. Resonance modes in optical fibres

    Institute of Scientific and Technical Information of China (English)

    余寿绵; 余恬

    2002-01-01

    The weakly nonlinear boundary value problem of wave propagation in an optical fibre (for the transverse electric mode, for example) is formulated and a modified linear solution is obtained. It is shown that a self-consistent theory of fibre optics should be weakly nonlinear. The mode of critical refraction that does not exist in the linear theory is obtained, showing that it is a mode consisting of resonance modes. It is shown that the signal carriers in a long fibre are of resonance modes, not normal modes. Some experimental data are given for comparison with the theoretical predictions, and the agreement seems satisfactory.

  14. Optical Fibre Based Frequency Shifters Project

    Science.gov (United States)

    1991-01-28

    A fibre optic frequency shifter can be used to replace the Bragg cell acousto-optic modulator, currently used to generate low frequency optical...carriers, in fibre optic communications and sensor systems. This new form of frequency shifter, being an all fibre device, in which the propagating optical...large number of workers in recent years, (for example references [2-81 and those contained therein). The main elements of a fibre - optic frequency

  15. Fibre Optics In Coal Mining

    Science.gov (United States)

    Cooper, Paul

    1984-08-01

    Coal mines have a number of unique problems which affect the use of fibre optic technology. These include a potentially explosive atmosphere due to the evolution of methane from coal, and a dirty environment with no cleaning facilities readily available. Equipment being developed by MRDE to allow the exploitation of optical fibres underground includes: A hybrid electrical/fibre optic connector for the flexible power trailing cable of the coal-face shearer; An Intrinsically Safe (IS) pulsed laser transmitter using Frequency Shift Key (FSK) data modulation; An IS Avalanche Photo Diode Receiver suitable for pulsed & continuous wave optical signals; A mine shaft and roadway cable/ connector system incorporating low loss butt-splices and preterminated demountable connectors.

  16. Fibre Optic Communication Key Devices

    CERN Document Server

    Grote, Norbert

    2012-01-01

    The book gives an in-depth description of the key devices of current and next generation fibre optic communication networks. In particular, the book covers devices such as semiconductor lasers, optical amplifiers, modulators, wavelength filters, and detectors but the relevant properties of optical fibres as well. The presentations include the physical principles underlying the various devices, the technologies used for the realization of the different devices, typical performance characteristics and limitations, and development trends towards more advanced components are also illustrated. Thus the scope of the book spans relevant principles, state-of-the-art implementations, the status of current research and expected future components.

  17. Tapered optical fibres for sensing

    Science.gov (United States)

    Martan, Tomas; Kanka, Jiri; Kasik, Ivan; Matejec, Vlastimil

    2008-11-01

    Recently, optical fibre tapers have intensively been investigated for many applications e.g. in telecommunications, medicine and (bio-) chemical sensing. The paper deals with enhancement of evanescent-field sensitivity of the solid-core microstructured fibre with steering-wheel air-cladding. Enhancement of a performance of the microstructured fibre is based on reduction of fibre core diameter down to narrow filament by tapering thereby defined part of light power is guided by an evanescent wave traveling in axial cladding air holes. The original fibre structure with outer diameter of 125 µm was reduced 2×, 2.5×, 3.33×, and 4× for increasing relatively small intensity overlap of guided core mode at wavelength of 1.55 μm with axial air holes. The inner structures of tapered microstructured fibre with steering-wheel aircladding were numerically analyzed and mode intensity distributions were calculated using the FDTD technique. Analyzed fiber tapers were prepared by constructed fibre puller employing 'flame brush technique'.

  18. Fibre optic communication key devices

    CERN Document Server

    Grote, Norbert

    2017-01-01

    The book gives an in-depth description of key devices of current and next generation fibre optic communication networks. Devices treated include semiconductor lasers, optical amplifiers, modulators, wavelength filters and other passives, detectors, all-optical switches, but relevant properties of optical fibres and network aspects are included as well. The presentations include the physical principles underlying the various devices, technologies used for their realization, typical performance characteristics and limitations, but development trends towards more advanced components are also illustrated. This new edition of a successful book was expanded and updated extensively. The new edition covers among others lasers for optical communication, optical switches, hybrid integration, monolithic integration and silicon photonics. The main focus is on Indium phosphide-based structures but silicon photonics is included as well. The book covers relevant principles, state-of-the-art implementations, status of curren...

  19. Portable smartphone optical fibre spectrometer

    Science.gov (United States)

    Hossain, Md. Arafat; Canning, John; Cook, Kevin; Jamalipour, Abbas

    2015-09-01

    A low cost, optical fibre based spectrometer has been developed on a smartphone platform for field-portable spectral analysis. Light of visible wavelength is collected using a multimode optical fibre and diffracted by a low cost nanoimprinted diffraction grating. A measurement range over 300 nm span (λ = 400 to 700 nm) is obtained using the smartphone CMOS chip. The spectral resolution is Δλ ~ 0.42 nm/screen pixel. A customized Android application processed the spectra on the same platform and shares with other devices. The results compare well with commercially available spectrometer.

  20. Periodic Structures in Optical Fibres.

    Science.gov (United States)

    Hand, Duncan Paul

    1990-01-01

    Available from UMI in association with The British Library. The work presented in this thesis concerns techniques for the formation of periodic structures in optical fibres. Two different methods of producing such structures are studied in detail. The first of these involves a breakdown mechanism (known as the 'fibre fuse') that permanently damages the core glass in a periodic manner leaving it unable to guide light. The dynamics of this mechanism are studied, with a view to controlling it for the production of interactive grating structures. It is determined that, due to a sharp rise in fibre absorption with temperature, a thermal shock -wave, with a typical thermal gradient of several hundred degrees Kelvin per micron, forms and travels along the fibre, heating the core glass to such an extent that damage occurs. The periodicity of the resultant damage arises from thermal focusing and defocusing of light in the region of this shock-wave. The second method makes use of the photorefractivity observed in certain germanosilicate fibres on exposure to moderate intensity blue light of wavelength ~480nm or UV light ~240nm. A single-mode fibre transmission filter is demonstrated for the first time, produced by exposing a fibre Sagnac loop mirror to 488nm holographic fringes. Average index changes are shown to occur if such fibres are exposed to spatially uniform blue or UV light, indicating that grating formation is by a different mechanism to the local charge separation which occurs in photorefractive crystals. The various characteristics of these average index changes are measured and analysed, with the conclusion that they result from defect centre formation, driven by two photon absorption with blue light, or single photon absorption with UV light. Associated birefringence changes are also measured and are exploited in a hi-bi fibre to periodically perturb the birefringence axes, producing a narrow-line transmission filter.

  1. Underwater Acoustic Sensing with Optical Fibres

    Directory of Open Access Journals (Sweden)

    V. V. Rampal

    1982-01-01

    Full Text Available The use of optical fibres for the detection of acoustic pressure underwater has been discussed with particular reference to the recent literature on the development of fibre optic hydrophones.

  2. Cool application for Optical Fibres

    CERN Multimedia

    2001-01-01

    In a new first for CERN, optical fibres have been put on test to measure very low temperatures. If these tests prove successful, this new technology could lead to important cost-saving changes in the way the temperatures of superconducting magnets are measured. There was excitement in the air last March when the team led by Walter Scandale and Luc Thévenaz tested very low temperature measurement using optical fibres. This spring in CERN's Cryogenics lab an idea was put to the test as a new kind of low-temperature thermometry using optical fibres was tested down to 2 Kelvin (around 300 degrees below room temperature), and the first results are looking good. Optical fibres are well known for their ability to carry large amounts of data around the world, but it is less well known that they can be used for measuring temperatures. The intuition that they might be able to measure very low temperatures - such as those of the LHC magnets - came to the attention of CERN's Walter Scandale at the Optical Fi...

  3. Wavelength Filters in Fibre Optics

    CERN Document Server

    Venghaus, Herbert

    2006-01-01

    Wavelength filters constitute an essential element of fibre-optic networks. This book gives a comprehensive account of the principles and applications of such filters, including their technological realisation. After an introductory chapter on wavelength division multiplexing in current and future fibre optic networks follows a detailed treatment of the phase characteristics of wavelength filters, a factor frequently neglected but of significant importance at high bit rates. Subsequent chapters cover three-dimensional reflection of gratings, arrayed waveguide gratings, fibre Bragg gratings, Fabry-Perot filters, dielectric multilayer filters, ring filters, and interleavers. The book explains the relevant performance parameters, the particular advantages and shortcomings of the various concepts and components, and the preferred applications. It also includes in-depth information on the characteristics of both commercially available devices and those still at the R&D stage. All chapters are authored by inter...

  4. Fibre-optic communications

    CERN Document Server

    Lecoy, Pierre

    2010-01-01

    This book describes in a comprehensive manner the components and systems of fiber optic communications and networks. The first section explains the theory of multimode and single-mode fibers, then the technological features, including manufacturing, cabling, and connecting. The second section describes the various components (passive and active optical components, integrated optics, opto-electronic transmitters and receivers, and optical amplifiers) used in fiber optic systems. Finally, the optical transmission system design is explained, and applications to optical networks and fiber optic se

  5. Nonlinear microstructured polymer optical fibres

    DEFF Research Database (Denmark)

    Frosz, Michael Henoch

    is potentially the case for microstructured polymer optical fibres (mPOFs). Another advantage is that polymer materials have a higher biocompatibility than silica, meaning that it is easier to bond certain types of biosensor materials to a polymer surface than to silica. As with silica PCFs, it is difficult...

  6. Threshold temperature optical fibre sensors

    Science.gov (United States)

    Stasiewicz, K. A.; Musial, J. E.

    2016-12-01

    This paper presents a new approach to manufacture a threshold temperature sensor based on a biconical optical fibre taper. The presented sensor employs the influence of variable state of concentration of some isotropic materials like wax or paraffin. Application of the above- mentioned materials is an attempt to prove that there is a possibility to obtain a low-cost, repeatable and smart sensor working as an in-line element. Optical fibre taper was obtained from a standard single mode fibre (SMF28®) by using a low pressure gas burner technique. The diameter of the manufactured tapers was 6.0 ± 0.5 μm with the length of elongation equal to 30.50 ± 0.16 mm. The applied technology allowed to produce tapers with the losses of 0.183 ± 0.015 dB. Application of materials with different temperature transition points made it possible to obtain the threshold work at the temperatures connected directly with their conversion temperature. External materials at the temperatures above their melting points do not influence the propagation losses. For each of them two types of the protection area and position of the optical fibre taper were applied.

  7. Nonlinear fibre optics overview

    DEFF Research Database (Denmark)

    Travers, J. C.; Frosz, Michael Henoch; Dudley, J. M.

    2010-01-01

    , provides a background to the associated nonlinear optical processes, treats the generation mechanisms from continuous wave to femtosecond pulse pump regimes and highlights the diverse applications. A full discussion of numerical methods and comprehensive computer code are also provided, enabling readers...

  8. Elimination of Cerenkov interference in a fibre-optic-coupled radiation dosemeter.

    Science.gov (United States)

    Justus, Brian L; Falkenstein, Paul; Huston, Alan L; Plazas, Maria C; Ning, Holly; Miller, Robert W

    2006-01-01

    An optical fibre point dosemeter based on the gated detection of the luminescence from a Cu(1+)-doped fused quartz detector effectively eliminated errors due to Cerenkov radiation and native fibre fluorescence. The gated optical fibre dosemeter overcomes serious problems faced by scintillation and optically stimulated luminescence approaches to optical fibre point dosimetry. The dosemeter was tested using an external beam radiotherapy machine that provided pulses of 6 MV X rays. Gated detection was used to discriminate the signal collected during the radiation pulses, which included contributions from Cerenkov radiation and native fibre fluorescence, from the signal collected between the radiation pulses, which contained only the long-lived luminescence from the Cu(1+)-doped fused quartz detector. Gated detection of the luminescence provided accurate, real-time dose measurements that were linear with absorbed dose, independent of dose rate and that were accurate for all field sizes studied.

  9. Polymeric Optical Fibres for Biomedical Sensing

    OpenAIRE

    Krehel, M P

    2014-01-01

    In this thesis we focus on the integration of optical fibres in textiles to create wearable sensing systems. In the introduction (Chapter 3) we describe the basics of light guiding in optical fibres and methods of lateral light coupling. Subsequently, a literature review and motivation are presented. Afterwards two main parts can be differentiated. In the first one (Chapters 4, 5) a new method of continuous extrusion of optical fibres and their medical sensing application using photoplethysmo...

  10. Recent advances in poled optical fibres

    DEFF Research Database (Denmark)

    Pruneri, V.; Margulis, W.; Myrén, N.

    2005-01-01

    A second-order nonlinearity can be induced in optical fibres through poling. We describe accomplishments of the EU project GLAMOROUS in making low-cost high performance electrooptic and nonlinear optical fibre- and waveguide-based components. In particular a comparison with more traditional...

  11. Recent advances in poled optical fibres

    DEFF Research Database (Denmark)

    Pruneri, V.; Margulis, W.; Myrén, N.;

    2005-01-01

    A second-order nonlinearity can be induced in optical fibres through poling. We describe accomplishments of the EU project GLAMOROUS in making low-cost high performance electrooptic and nonlinear optical fibre- and waveguide-based components. In particular a comparison with more traditional...

  12. Carbon fibre tips for scanning probe microscopy based on quartz tuning fork force sensors

    Energy Technology Data Exchange (ETDEWEB)

    Castellanos-Gomez, A; Agrait, N; Rubio-Bollinger, G, E-mail: gabino.rubio@uam.es [Departamento de Fisica de la Materia Condensada (C-III), Universidad Autonoma de Madrid, Campus de Cantoblanco, 28049 Madrid (Spain)

    2010-04-09

    We report the fabrication and the characterization of carbon fibre tips for use in combined scanning tunnelling and force microscopy based on piezoelectric quartz tuning fork force sensors. We find that the use of carbon fibre tips results in a minimum impact on the dynamics of quartz tuning fork force sensors, yielding a high quality factor and, consequently, a high force gradient sensitivity. This high force sensitivity, in combination with high electrical conductivity and oxidation resistance of carbon fibre tips, make them very convenient for combined and simultaneous scanning tunnelling microscopy and atomic force microscopy measurements. Interestingly, these tips are quite robust against occasionally occurring tip crashes. An electrochemical fabrication procedure to etch the tips is presented that produces a sub-100-nm apex radius in a reproducible way which can yield high resolution images.

  13. Multicore optical fibre and fibre-optic delay line based on it

    Science.gov (United States)

    Egorova, O. N.; Astapovich, M. S.; Belkin, M. E.; Semjonov, S. L.

    2016-12-01

    The first switchable fibre-optic delay line based on a 1300-{\\text{m}}-long multicore optical fibre has been fabricated and investigated. We have obtained signal delay times of up to 45 \\unicode{956}{\\text{s}} at 6.43-\\unicode{956}{\\text{s}} intervals. Sequential signal propagation through the cores of the multicore optical fibre makes it possible to reduce the fibre length necessary for obtaining a predetermined delay time, which is important for reducing the weight and dimensions of devices based on the use of fibre-optic delay lines.

  14. Fibre Optic Protection System for Concrete Structures

    Institute of Scientific and Technical Information of China (English)

    J.S.Leng; A.Hameed; D.Winter; R.A.Barnes; G.C.Mays; G.F.Fernando

    2006-01-01

    The design concepts, modelling and implementation of various fibre optic sensor protection systems for development in concrete structures were investigated. Design concepts and on-site requirements for surface-mounted and embedded optical fibre sensor in concrete were addressed. Finite element (FE) modelling of selected sensor protection systems in strain-transfer efficiency from the structure to the sensing region was also studied. And experimental validation of specified sensor protection system was reported. Results obtained indicate that the protection system for the sensors performs adequately in concrete environment and there is very good correlation between results obtained by the protected fibre optic sensors and conventional electrical resistance strain gauges.

  15. The development of fibre optic microbend sensors

    NARCIS (Netherlands)

    Horsthuis, W.H.G.; Fluitman, J.H.J.

    1983-01-01

    Investigations concerning the development of a fibre optic pressure sensor are reported. The phenomenon of light power attenuation in a periodically deformed graded index fibre has been studied theoretically. It appears that available theories are not suited to describe this attenuation process in t

  16. Insertion of optic fibre for CMS

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    The MicroJET system uses high pressure to carefully put the optical fibres into their protective tubes. These fibres are vital for rapid data transfer, but are also very delicate and, if damanged, may not work at the required efficiency. Similiar methods are used to install cables for the telecommunications industry.

  17. Optical fibres bringing the LHC into focus

    CERN Multimedia

    2003-01-01

    New components are being added to CERN's optical fibre network, which will transport the torrents of data produced by the LHC. 1500 kilometres of cables will be installed in the tunnels and at ground level.

  18. Optical Fibre Pressure Sensors in Medical Applications

    Directory of Open Access Journals (Sweden)

    Sven Poeggel

    2015-07-01

    Full Text Available This article is focused on reviewing the current state-of-the-art of optical fibre pressure sensors for medical applications. Optical fibres have inherent advantages due to their small size, immunity to electromagnetic interferences and their suitability for remote monitoring and multiplexing. The small dimensions of optical fibre-based pressure sensors, together with being lightweight and flexible, mean that they are minimally invasive for many medical applications and, thus, particularly suited to in vivo measurement. This means that the sensor can be placed directly inside a patient, e.g., for urodynamic and cardiovascular assessment. This paper presents an overview of the recent developments in optical fibre-based pressure measurements with particular reference to these application areas.

  19. Fibre-optic sensors in health care

    Science.gov (United States)

    Grazia Mignani, Anna; Baldini, Francesco

    1997-05-01

    Biomedical fibre-optic sensors are attractive for the measurement of physical, chemical and biochemical parameters and for spectral measurements directly performed on the patient. An overview of fibre-optic sensors for in vivo monitoring is given, with particular attention paid to the advantages that these sensors are able to offer in different application fields such as cardiovascular and intensive care, angiology, gastroenterology, ophthalmology, oncology, neurology, dermatology and dentistry.

  20. Fibre optic power meter calibration uncertainties

    CSIR Research Space (South Africa)

    Nel, M

    2010-06-01

    Full Text Available thereof. It was done only for standard single mode fibre with FC (ferrule connector) connectors, and using a 1310 and a 1550 nm Fabry Perot laser (FP laser). The calibration set-up and procedure The uncertainty contributions for fibre optic power..., in this case 1310 or 1550 nm, is fed to the fibre optic power meter (secondary standard or unit under test (UUT)) via an attenuator. The attenuator serves to reduce back-reflections into the source and to set the power to the desired level. In Fig. 1...

  1. Economics Of Optical Fibre Transmission Systems

    Science.gov (United States)

    Murray, W. J.

    1983-08-01

    Optical fibre as a telecommunication transmission medium has become one of the most significant developments so far of the digital era. A major contributory factor to the availability of optical fibre transmission systems has been the outstanding progress in the technology of manufacturing high quality glass fibre having relatively low attenuation and broad bandwidths. This and other achievements has enabled manufacturers in the United Kingdom to develop a range of optical fibre cables and transmission equipment for operation over short and long distances at the CCITT recommended digital hierarchical rates of 2, 8, 34 and 140Mbit/s which have been adopted by British Telecom (BT) for modernisation to an all digital transmission network. These optical fibre systems are now becoming increasingly price and performance competitive with conventional technology in many parts of telecommunications networks. In the British Telecom (BT) network the 140Mbit/s optical fibre systems are now economically competitive with equivalent systems on coaxial cable and microwave radio. The economics of 8 and 34Mbit/s systems are not yet sufficiently attractive, compared with 2Mbit/s digital line systems on pair type copper cables, for large scale use in rural and local distribution networks and are presently only justified on cost in and around large cities. As system costs decrease large applications are predicted particularly in support of future high speed data, cable television and visual information services.

  2. Fibre-optic nonlinear optical microscopy and endoscopy.

    Science.gov (United States)

    Fu, L; Gu, M

    2007-06-01

    Nonlinear optical microscopy has been an indispensable laboratory tool of high-resolution imaging in thick tissue and live animals. Rapid developments of fibre-optic components in terms of growing functionality and decreasing size provide enormous opportunities for innovations in nonlinear optical microscopy. Fibre-based nonlinear optical endoscopy is the sole instrumentation to permit the cellular imaging within hollow tissue tracts or solid organs that are inaccessible to a conventional optical microscope. This article reviews the current development of fibre-optic nonlinear optical microscopy and endoscopy, which includes crucial technologies for miniaturized nonlinear optical microscopy and their embodiments of endoscopic systems. A particular attention is given to several classes of photonic crystal fibres that have been applied to nonlinear optical microscopy due to their unique properties for ultrashort pulse delivery and signal collection. Furthermore, fibre-optic nonlinear optical imaging systems can be classified into portable microscopes suitable for imaging behaving animals, rigid endoscopes that allow for deep tissue imaging with minimally invasive manners, and flexible endoscopes enabling imaging of internal organs. Fibre-optic nonlinear optical endoscopy is coming of age and a paradigm shift leading to optical microscope tools for early cancer detection and minimally invasive surgery.

  3. Simulation of complex phenomena in optical fibres

    CERN Document Server

    Allington-Smith, Jeremy; Lemke, Ulrike

    2012-01-01

    Optical fibres are essential for many types of highly-multiplexed and precision spectroscopy. The success of the new generation of multifibre instruments under construction to investigate fundamental problems in cosmology, such as the nature of dark energy, requires accurate modellisation of the fibre system to achieve their signal-to-noise goals. Despite their simple construction, fibres exhibit unexpected behaviour including non-conservation of Etendue (Focal Ratio Degradation; FRD) and modal noise. Furthermore, new fibre geometries (non-circular or tapered) have become available to improve the scrambling properties that, together with modal noise, limit the achievable SNR in precision spectroscopy. These issues have often been addressed by extensive tests on candidate fibres and their terminations but these are difficult and time-consuming. Modelling by ray-tracing and wave analysis is possible with commercial software packages but these do not address the more complex features, in particular FRD. We use a...

  4. Special Polymer Optical Fibres and Devices for Photonic Applications

    Institute of Scientific and Technical Information of China (English)

    Gang-Ding Peng

    2003-01-01

    Remarkable progresses have been made in developing special polymer optical fibres and devices for photonic applications in recent years. This presentation will mainly report on the development of electro-optic, photosensitive and photorefractive polymer optical fibres and related devices.

  5. Simulation of complex phenomena in optical fibres

    Science.gov (United States)

    Allington-Smith, Jeremy; Murray, Graham; Lemke, Ulrike

    2012-12-01

    Optical fibres are essential for many types of highly multiplexed and precision spectroscopy. The success of the new generation of multifibre instruments under construction to investigate fundamental problems in cosmology, such as the nature of dark energy, requires accurate modellization of the fibre system to achieve their signal-to-noise ratio (SNR) goals. Despite their simple construction, fibres exhibit unexpected behaviour including non-conservation of etendue (focal ratio degradation, FRD) and modal noise. Furthermore, new fibre geometries (non-circular or tapered) have become available to improve the scrambling properties that, together with modal noise, limit the achievable SNR in precision spectroscopy. These issues have often been addressed by extensive tests on candidate fibres and their terminations, but these are difficult and time-consuming. Modelling by ray tracing and wave analysis is possible with commercial software packages, but these do not address the more complex features, in particular FRD. We use a phase-tracking ray-tracing method to provide a practical description of FRD derived from our previous experimental work on circular fibres and apply it to non-standard fibres. This allows the relationship between scrambling and FRD to be quantified for the first time. We find that scrambling primarily affects the shape of the near-field pattern but has negligible effect on the barycentre. FRD helps to homogenize the near-field pattern but does not make it completely uniform. Fibres with polygonal cross-section improve scrambling without amplifying the FRD. Elliptical fibres, in conjunction with tapering, may offer an efficient means of image slicing to improve the product of resolving power and throughput, but the result is sensitive to the details of illumination. We also investigated the performance of fibres close to the limiting numerical aperture since this may affect the uniformity of the SNR for some prime focus fibre instrumentation.

  6. Optical fibre cantilever sensor for biological application

    Science.gov (United States)

    Li, J.; Zhou, Y. X.; Patterson, G.; Shu, W. M.; Maier, R. R. J.; Fowler, R.; Hand, D. P.; MacPherson, W. N.

    2014-05-01

    Micro-cantilever sensors have shown great promise in a wide range of application are as including chemical and biological sensing. However, many of these devices are based upon a sensor `chip' that requires careful alignment between the cantilever and the read-out system, which can be challenging. Furthermore, optical interrogation typically involves a bulky free-space system. Optical fibre addressed cantilevers have been reported previously in the literature and in this paper we propose techniques to design and fabricate polymer micro-cantilevers for attachment onto the end of standard single mode fibres using laser machining. Low-cost optical sources and a fibre coupled spectrometer are employed to monitor the cantilever deflection and therefore observe biological binding between a species of interest and an activated cantilever. Proof-of-concept experiments show that the sensor is capable of detecting pathogen concentration with down to a level of 105cfu/ml.

  7. Space Division Multiplexing in Optical Fibres

    CERN Document Server

    Richardson, D J; Nelson, L E

    2013-01-01

    Optical communications technology has made enormous and steady progress for several decades, providing the key resource in our increasingly information-driven society and economy. Much of this progress has been in finding innovative ways to increase the data carrying capacity of a single optical fibre. In this search, researchers have explored (and close to maximally exploited) every available degree of freedom, and even commercial systems now utilize multiplexing in time, wavelength, polarization, and phase to speed more information through the fibre infrastructure. Conspicuously, one potentially enormous source of improvement has however been left untapped in these systems: fibres can easily support hundreds of spatial modes, but today's commercial systems (single-mode or multi-mode) make no attempt to use these as parallel channels for independent signals.

  8. Photothermal determination of optical coefficients using an optical fibre sensor

    CERN Document Server

    Laufer, J

    2000-01-01

    configuration is more sensitive to the thermal coefficients than the optical coefficients of the target. Pulsed photothermal radiometry was found to have higher sensitivity to the optical coefficients than has the optical fibre sensor in its present form. However, modifications to the configuration of the sensor can produce a performance matching that of pulsed photothermal radiometry. This thesis is concerned with the development of an optical fibre sensor for the photothermal determination of the optical coefficients of tissue. The detection of differences in tissue optical properties might be used for the diagnosis of cancers and other tissue pathologies. The sensor consists of a thin transparent polymer film mounted at the distal end of an optical fibre. The film acts as a Fabry-Perot interferometer. The absorption of short, low energy laser pulses transmitted through the film and into the tissue generates thermal as well as acoustic transients, which propagate into/the film and modulate its thickness. Th...

  9. Optical rogue waves and soliton turbulence in nonlinear fibre optics

    DEFF Research Database (Denmark)

    Genty, G.; Dudley, J. M.; de Sterke, C. M.

    2009-01-01

    We examine optical rogue wave generation in nonlinear fibre propagation in terms of soliton turbulence. We show that higher-order dispersion is sufficient to generate localized rogue soliton structures, and Raman scattering effects are not required.......We examine optical rogue wave generation in nonlinear fibre propagation in terms of soliton turbulence. We show that higher-order dispersion is sufficient to generate localized rogue soliton structures, and Raman scattering effects are not required....

  10. Measuring method for optical fibre sensors

    NARCIS (Netherlands)

    Lammerink, Theodorus S.J.; Fluitman, J.H.J.

    1984-01-01

    A new measuring method for the signal amplitude in intensity modulating fibre optic sensors is described. A reference signal is generated in the time domain. The method is insensitive for the sensitivity fluctuations of the light transmitter and the light receiver. The method is experimentally

  11. Measuring method for optical fibre sensors

    NARCIS (Netherlands)

    Lammerink, T.S.J.; Fluitman, J.H.J.

    1984-01-01

    A new measuring method for the signal amplitude in intensity modulating fibre optic sensors is described. A reference signal is generated in the time domain. The method is insensitive for the sensitivity fluctuations of the light transmitter and the light receiver. The method is experimentally teste

  12. Fibre optic communications: past, present and future

    Directory of Open Access Journals (Sweden)

    B. M. Lacquet

    2000-07-01

    Full Text Available The exponential increase in the use of the Internet and the consequent growing need for higher bandwidth demand that the telecommu­nications industry expand the laid networks at a much faster rate. Optical fibre is the only transmission medium that has the potential of unlimited bandwidth and the ability to handle very high data rates.

  13. Optical Fibre Dosimeter for SASE FEL Undulators

    CERN Document Server

    Körfer, M

    2003-01-01

    Single pass Free Electron Lasers (FELs) based on self-amplified spontaneous emission (SASE) are developed for high brightness and short wavelength applications. They use permanent magnet undulators which are radiation sensitive devices. During accelerator commissioning beam losses can appear anywhere along the undulator line. To avoid damage of the permanent magnets due to radiation, an optical fibre dosimeter system can be used. The increase of absorption caused by ionizing radiation is measured in radiation sensitive optical fibers. The dose system enables relatively fast particle loss tuning during accelerator operation and allows the monitoring of the accumulated dose. Dose measurements in narrow gaps which are inaccessible for any other (online) dosimeter type become possible. The electromagnetic insensitivity of optical fibre sensor is an advantage of applications in strong magnetic undulator fields. At each location the light absorption is measured by using an optical power-meter. The dynamic range is ...

  14. EDITORIAL: Optical Fibre Sensors 18 (OFS-18)

    Science.gov (United States)

    Jones, Julian D. C.; Tatam, Ralph P.

    2007-10-01

    The International Conference on Optical Fibre Sensors (OFS-18) was held in October 2006 in Cancún, Mexico, under the general chairmanship of Dr Alexis Mendez (MCH Engineering LLC, USA) and Dr Fernando Mendoza (Centro de Investigaciones en Optica, Mexico). 'OFS', as it has become known, is firmly established as the leading international conference for the optical fibre sensor community. Since its inception, in London in 1983, and under the leadership of an international steering committee independent of any learned society or professional institution, it has been held approximately every eighteen months. The venue nominally rotates from Europe, to the Americas, and thence to Asia and the Pacific. OFS-18 demonstrated the continuing vigour of the community, with some 250 papers presented, plus two workshops, with attendance as international as ever. In recent years, it has become a tradition to publish a post-conference special issue in the journal Measurement Science and Technology, and these special issues offer a representative sample of the current status of the field. In the nearly 25 years since OFS began, many of the early ideas and laboratory-based proof-of-principle experiments have led to highly developed instrumentation systems, and to successful commercial products. Perhaps the most mature of all of these technologies is the optical fibre gyroscope, with the fibre hydrophone a close second—originally developed for defence applications for which it is now established, but with increasing relevance to the oil and gas industry; electromagnetic sensors based on the Faraday and electro-optic effects are of growing significance in the power generation and distribution industry; whilst in-fibre grating-based sensors occupy an expanding niche in structural monitoring, especially in civil engineering. It is therefore appropriate that the first day of OFS was devoted to workshops on structural health monitoring, and to commemorate the 30th anniversary of the

  15. Surface modification of quartz fibres for dental composites through a sol-gel process.

    Science.gov (United States)

    Wang, Yazi; Wang, Renlin; Habib, Eric; Wang, Ruili; Zhang, Qinghong; Sun, Bin; Zhu, Meifang

    2017-05-01

    In this study, quartz fibres (QFs) surface modification using a sol-gel method was proposed and dental posts reinforced with modified QFs were produced. A silica sol (SS) was prepared using tetraethoxysilane (TEOS) and 3-methacryloxypropyltrimethoxysilane (γ-MPS) as precursors. The amount of γ-MPS in the sol-gel system was varied from 0 to 24wt.% with a constant molar ratio of TEOS, ethanol, deionized water, and HCl. Thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FT-IR), and contact angle (CA) measurements were used to characterize the modified QFs, which confirmed that SS had successfully coated the surface of QFs. SEM images showed good interfacial bonding between the modified QFs and the resin matrix. The results of three-point bending tests of the fibre reinforced composite (FRC) posts showed that the QFs modified by SS with 12wt.% γ-MPS presented the best mechanical properties, demonstrating improvements of 108.3% and 89.6% for the flexural strength and flexural modulus, respectively, compared with untreated QFs. Furthermore, the sorption and solubility of the prepared dental posts were also studied by immersing the posts in artificial saliva (AS) for 4weeks, and yielded favourable results. This sol-gel surface modification method promises to resolve interfacial bonding issues of fibres with the resin matrix, and produce FRC posts with excellent properties.

  16. Nonlinear microstructured polymer optical fibres

    DEFF Research Database (Denmark)

    Frosz, Michael Henoch

    . The combination of a small core size and zero-dispersion wavelength at the operating wavelength of widely available femtosecond Ti:sapphire lasers led to an extensive research in supercontinuum generation and other nonlinear effects in PCFs. It is crucial for the efficiency of many nonlinear mechanisms...... that the pump laser wavelength is close to the zero-dispersion wavelength and that the core size is small. Recently, work in fabricating PCFs from materials other than silica has intensified. One of the advantages of using alternative materials can be a higher inherent material nonlinearity, which...... to accurately obtain a small core size while maintaining small structural variations during fibre drawing. This talk will give a presentation of how the mPOFs are fabricated and the route to obtaining nonlinear effects in them....

  17. Fibre-Optic Strain Measurement For Structural Integrity Monitoring

    NARCIS (Netherlands)

    Bruinsma, A.J.A.; Zuylen, P. van; Lamberts, C.W.; Krijger, A.J.T. de

    1984-01-01

    A method is demonstrated for monitoring the structural integrity of large structures, using an optical fibre. The strain distribution along the structure is monitored by measuring the attentuation of light along the length of the fibre.

  18. Rare Earth Doped Optical Fibre From Oxide Nanoparticles

    Institute of Scientific and Technical Information of China (English)

    Minati Chatterjee; Aharon Gedanken; Renata Reisfeld; Ranjan Sen; Mrinmay Pal; Milan Naskar; Mukul Paul; Shyamal Bhadra; Kamal Dasgupta; Dibyendu Ganguli; Tarun Bandyopadhyay

    2003-01-01

    Rare earth (RE) doped optical fibres were fabricated by using RE oxides coated silica nanoparticles. The fibre properties are comparable to those prepared by conventional techniques. The process offers better control over RE incorporation and homogeneity in the preform.

  19. Zeonex Microstructured Polymer Optical Fibre Bragg Grating Sensor

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Fasano, Andrea; Markos, Christos

    2016-01-01

    We fabricated an endlessly single mode and humidity insensitive Zeonex microstructured polymer optical fibre (mPOF) for fibre Bragg grating (FBG) temperature and strain sensors. We inscribed and characterise FBGs in Zeonex mPOF for the first time.......We fabricated an endlessly single mode and humidity insensitive Zeonex microstructured polymer optical fibre (mPOF) for fibre Bragg grating (FBG) temperature and strain sensors. We inscribed and characterise FBGs in Zeonex mPOF for the first time....

  20. Fibre Optic Sensors for Selected Wastewater Characteristics

    Directory of Open Access Journals (Sweden)

    Sulaiman W. Harun

    2013-07-01

    Full Text Available Demand for online and real-time measurements techniques to meet environmental regulation and treatment compliance are increasing. However the conventional techniques, which involve scheduled sampling and chemical analysis can be expensive and time consuming. Therefore cheaper and faster alternatives to monitor wastewater characteristics are required as alternatives to conventional methods. This paper reviews existing conventional techniques and optical and fibre optic sensors to determine selected wastewater characteristics which are colour, Chemical Oxygen Demand (COD and Biological Oxygen Demand (BOD. The review confirms that with appropriate configuration, calibration and fibre features the parameters can be determined with accuracy comparable to conventional method. With more research in this area, the potential for using FOS for online and real-time measurement of more wastewater parameters for various types of industrial effluent are promising.

  1. Fibre optic sensors for selected wastewater characteristics.

    Science.gov (United States)

    Chong, Su Sin; Aziz, A R Abdul; Harun, Sulaiman W

    2013-07-05

    Demand for online and real-time measurements techniques to meet environmental regulation and treatment compliance are increasing. However the conventional techniques, which involve scheduled sampling and chemical analysis can be expensive and time consuming. Therefore cheaper and faster alternatives to monitor wastewater characteristics are required as alternatives to conventional methods. This paper reviews existing conventional techniques and optical and fibre optic sensors to determine selected wastewater characteristics which are colour, Chemical Oxygen Demand (COD) and Biological Oxygen Demand (BOD). The review confirms that with appropriate configuration, calibration and fibre features the parameters can be determined with accuracy comparable to conventional method. With more research in this area, the potential for using FOS for online and real-time measurement of more wastewater parameters for various types of industrial effluent are promising.

  2. Fabrication of Polymer Optical Fibre (POF Gratings

    Directory of Open Access Journals (Sweden)

    Yanhua Luo

    2017-03-01

    Full Text Available Gratings inscribed in polymer optical fibre (POF have attracted remarkable interest for many potential applications due to their distinctive properties. This paper overviews the current state of fabrication of POF gratings since their first demonstration in 1999. In particular we summarize and discuss POF materials, POF photosensitivity, techniques and issues of fabricating POF gratings, as well as various types of POF gratings.

  3. Fibre optic sensors for mine hazard detection

    Energy Technology Data Exchange (ETDEWEB)

    Liu, T; Wang, C; Wei, Y; Zhao, Y; Shang, Y; Wang, Z [Laser Institute of Shandong Academy of Science (China); Huo, D [Shandong Micro-Sensor Photonics Limited, 19 Keyuan Road, Jinan, Shandong province, 250014 (China); Ning, Y, E-mail: tongyuliu@hotmail.co [Intelligent Sensor Systems Limited, Rockley Manor, Rockley, Wiltshire (United Kingdom)

    2009-07-01

    We report the development of a comprehensive safety monitoring solution for coal mines. A number of fibre optic sensors have been developed and deployed for safety monitoring of mine roof integrity and hazardous gases. The FOS-based mine hazard detection system offers unique advantages of intrinsic safety, multi-location and multi-parameter monitoring. They can be potentially used to build expert systems for mine hazard early detection and prevention.

  4. Optical fibre cable selection for electricity utilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    The report provides an assessment of the range of optical fibre cable solutions available, by type e.g. OPGW, ADSS, rather than by design. it also examines the key issues which will influence an electricity utilities decisions and proposes a method of evaluating the options to identify the one which most closely matches the utility's critical needs, with measurements against time, cost and quality targets. (author)

  5. Fibre optic sensor with disturbance localization in one optical fibre

    Science.gov (United States)

    Zyczkowski, M.; Ciurapinski, W.

    2007-05-01

    Ordinary perimeter security systems consist of many individual sensors with detection range 200-300 meters. These limitations are connected with physical phenomena that are used in microwave and infrared barriers as well as in ground and fence cable sensors. On the contrary, fiber optic perimeter sensors can be applied in the range of many kilometers and zone length 200-300 meters is degradation of their possibilities. This paper presents investigation results of a new generation of the fiber optic perimeter sensor in a two Sagnac and Sagna'c interferometers configuration. This system can detect a potential intruder and determine its position along a protected zone. We propose a method that makes use of the inherent properties of both interferometers. After demodulation of signals from both interferometers, obtained amplitude characteristic of the Sagnac interferometer depends on position of a disturbance along the both interferometer. So, quotient of both demodulated characteristics is proportional to the position of the disturbance. Arrangement of a laboratory model of the sensor and its signal processing scheme is presented. During research of a laboratory model, it was possible to detect the position of the disturbance with resolution of about 50m along a 10-km long sensor.

  6. Distributed quantum computation via optical fibres

    CERN Document Server

    Serafini, A; Bose, S; Serafini, Alessio; Mancini, Stefano; Bose, Sougato

    2005-01-01

    We investigate the possibility of realising effective quantum gates between two atoms in distant cavities coupled by an optical fibre. We show that highly reliable swap and entangling gates are achievable. We exactly study the stability of these gates in presence of imperfections in coupling strengths and interaction times and prove them to be robust. Moreover, we analyse the effect of spontaneous emission and losses and show that such gates are very promising in view of the high level of coherent control currently achievable in optical cavities.

  7. Chalcogenide Fibre Displacement Sensor

    Science.gov (United States)

    2001-06-01

    Fibre optic technology offers the possibility for developing of a variety of physical sensors for a wide range of physical parameters. The main...integrating sphere. The use of chalcogenide rather quartz fibre optic highly increases the Sensitivity of the sensor. Experimental set-up, transmission characteristics and technical parameters are presented.

  8. A fibre optic dosimeter customised for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Suchowerska, N. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia)], E-mail: Natalka@email.cs.nsw.gov.au; Lambert, J.; Nakano, T. [Department of Radiation Oncology, Royal Prince Alfred Hospital, Camperdown, NSW 2050 (Australia); School of Physics, University of Sydney, NSW 2006 (Australia); Law, S. [School of Physics, University of Sydney, NSW 2006 (Australia); Optical Fibre Technology Centre, University of Sydney, 206 National Innovation Centre, Australian Technology Park, Eveleigh, NSW 1430 (Australia); Elsey, J. [Bandwidth Foundry Pty Ltd, Australian Technology Park, NSW, 1430 (Australia); McKenzie, D.R. [School of Physics, University of Sydney, NSW 2006 (Australia)

    2007-04-15

    In-vivo dosimetry for brachytherapy cancer treatment requires a small dosimeter with a real time readout capability that can be inserted into the patient to determine the dose to critical organs. Fibre optic scintillation dosimeters, consisting of a plastic scintillator coupled to an optical fibre, are a promising dosimeter for this application. We have implemented specific design features to optimise the performance of the dosimeter for specific in-vivo dosimetry during brachytherapy. Two sizes of the BrachyFOD{sup TM} scintillation dosimeter have been developed, with external diameters of approximately 2 and 1 mm. We have determined their important dosimetric characteristics (depth dose relation, angular dependence, energy dependence). We have shown that the background signal created by Cerenkov and fibre fluorescence does not significantly affect the performance in most clinical geometries. The dosimeter design enables readout at less than 0.5 s intervals. The clinical demands of real time in-vivo brachytherapy dosimetry can uniquely be satisfied by the BrachyFOD{sup TM}.

  9. A Fibre Optic Sensor Of Physiological Parameters

    Science.gov (United States)

    Legendre, J. P.; Forester, G. V.

    1986-11-01

    This paper presents an ultraminiature fibre optic probe capable of physiological monitoring in situ. The system has been described previously where a fibre optic reflectometer was configured as a temperature sensor and as a refractometer. For the present experiments a bare fibre tip was used as sensing element. We show that we have been able to monitor cyclic physiological parameters such as heart and respiratory rates in various animal preparations. The probe has been used to obtain signals from the oesophagus, the lower gastro-intestinal tract, the abdominal cavity and from blood vessels (arteries and veins). The probe has also measured phasic activity coincident with mechanical activity of isolated heart muscle. The small physical size of the sensor (125 µm diameter), its flexibility and the fact that it is biologically inert are all very important characteristics for medical and biological considerations. Most recently, the probe has been used to monitor cardiac and respiratory rates while obtaining NMR spectra assessing metabolic activity. This was possible only because the probe is magnetically transparent.

  10. Optical fibre Bragg grating recorded in TOPAS cyclic olefin copolymer

    DEFF Research Database (Denmark)

    Johnson, I.P.; Yuan, Scott Wu; Stefani, Alessio

    2011-01-01

    A report is presented on the inscription of a fibre Bragg grating into a microstructured polymer optical fibre fabricated from TOPAS cyclic olefin copolymer. This material offers two important advantages over poly (methyl methacrylate), which up to now has formed the basis for polymer fibre Bragg...

  11. Fibre Optic Biosensor Assay of Newcastle Disease Virus

    Science.gov (United States)

    1993-10-01

    A fluorometric sandwich immunoassay for Newcastle disease virus (NDV) was developed using a fibre optic biosensor. Antibodies directed against NDV...and low baseline variation. These and other properties of the fibre optic biosensor indicate that it has the potential to serve as an on-line...continuous monitoring device of an automated or semiautomated detection system. As a part of the fibre optic biosensor development, the surface coverage of

  12. A Prototype Fibre Optic Gyroscope for Missile Guidance Applications,

    Science.gov (United States)

    This paper describes the design of a prototype fibre optic gyro, which is intended for missile guidance applications. Important design constraints...beam-splitter. Serrodyne phase ramps are impressed on the light propagating round the fibre optic sensor coil connected to the integrated optics chip

  13. Phenomena of optic-bound effect on fibre optic gyro

    Institute of Scientific and Technical Information of China (English)

    Song Ning-Fang; Zhang Chun-Xi; Jin Jing

    2007-01-01

    The optic-bound effect on fibre optic gyro (FOG) precision is analysed theoretically,and formulas describing the change of FOG light power under the action of optic-bound effect axe given.It is confirmed that optic-bound effect is a main instantaneous non-reciprocity effect of FOG in addition to the Sagnac effect and can lead to a dynamic error of FOG in practical environments.An approach to suppressing or eliminating the error due to the optic-bound effect is presented and verified experimentally.The result shows that the approach is valid and the precision of FOG is improved observably.

  14. Fibre optic portable rail vehicle detector

    Science.gov (United States)

    Kepak, Stanislav; Cubik, Jakub; Zavodny, Petr; Hejduk, Stanislav; Nedoma, Jan; Davidson, Alan; Vasinek, Vladimir

    2016-12-01

    During track maintenance operations, the early detection of oncoming rail vehicles is critical for the safety of maintenance personnel. In addition, the detection system should be simple to install at the trackside by minimally qualified personnel. Fibre optic based sensor systems have the inherent advantages of being passive, unaffected by radio frequency interference (RFI) and suffering very low signal attenuation. Such a system therefore represents a good alternative to conventional approaches such as ultrasonic based sensor systems. The proposed system consists of one or more passive fibre trackside sensors and an x86 processing unit located at the work site. The solid fibre connection between sensors and processing unit eliminates the risk of RFI. In addition, the detection system sensors are easy to install with no requirement for electrical power at the sensor site. The system was tested on a tram line in Ostrava with the results obtained indicating the successful detection of all the trams in the monitoring windows using a single sensor. However, the platform allows flexibility in configuring multiple sensors where required by system users.

  15. Optically stimulated exoelectron emission processes in quartz: comparison of experiment and theory

    DEFF Research Database (Denmark)

    Pagonis, V.; Ankjærgaard, Christina; Murray, A.S.

    2009-01-01

    Recent experiments have demonstrated that it is possible to measure optically stimulated exoelectron emission (OSE) signals simultaneously with optically stimulated luminescence (OSL) from quartz samples. These experiments provide valuable information on the charge movement in quartz grains. Two...

  16. Spider silk: a novel optical fibre for biochemical sensing

    Science.gov (United States)

    Hey Tow, Kenny; Chow, Desmond M.; Vollrath, Fritz; Dicaire, Isabelle; Gheysens, Tom; Thévenaz, Luc

    2015-09-01

    Whilst being thoroughly used in the textile industry and biomedical sector, silk has not yet been exploited for fibre optics-based sensing although silk fibres directly obtained from spiders can guide light and have shown early promises to being sensitive to some solvents. In this communication, a pioneering optical fibre sensor based on spider silk is reported, demonstrating for the first time the use of spider silk as an optical fibre sensor to detect polar solvents such as water, ammonia and acetic acid.

  17. Optical inclinometer based on fibre-taper-modal Michelson interferometer

    Science.gov (United States)

    Amaral, L. M. N.; Frazão, O.; Santos, J. L.; Lobo Ribeiro, A. B.

    2010-09-01

    An inclinometer sensor based on optical fibre-taper-modal Michelson interferometer is demonstrated. The magnitude of the tilt (bending angle of the fibre taper interferometer) is obtained by passive interferometric interrogation based on the generation of two quadrature phase-shifted signals from two fibre Bragg gratings. Optical phase-to-rotation sensitivity of 1.13 rad/degree with a 14 mrad/√Hz resolution is achieved.

  18. Corrosion induced strain monitoring through fibre optic sensors

    Energy Technology Data Exchange (ETDEWEB)

    Grattan, S K T [School of Planning, Architecture and Civil Engineering, Queen' s University Belfast, David Keir Building, Belfast, BT9 5AG (United Kingdom); Basheer, P A M [School of Planning, Architecture and Civil Engineering, Queen' s University Belfast, David Keir Building, Belfast, BT9 5AG (United Kingdom); Taylor, S E [School of Planning, Architecture and Civil Engineering, Queen' s University Belfast, David Keir Building, Belfast, BT9 5AG (United Kingdom); Zhao, W [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom); Sun, T [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom); Grattan, K T V [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom)

    2007-10-15

    The use of strain sensors is commonplace within civil engineering. Fibre optic strain sensors offer a number of advantages over the current electrical resistance type gauges. In this paper the use of fibre optic strain sensors and electrical resistance gauges to monitor the production of corrosion by-products has been investigated and reported.

  19. Initial research of dual wavelength fibre optic perimeter sensor

    Science.gov (United States)

    Zyczkowski, M.; Kondrat, M.; Ciurapinski, W.

    2005-10-01

    The dual wavelength fibre optic perimeter sensor bases on input signals measurements in an arrangement of fibre optic Michelson and Sagnac interferometers with a 3 × 3 coupler and two semiconductor lasers. For 3 km long sensor we obtained 20-50m resolution of determination of disturbance point.

  20. Semiconductor optical fibres for infrared applications: A review

    Science.gov (United States)

    Peacock, Anna C.; Healy, Noel

    2016-10-01

    Over the last decade a new class of optical fibre has emerged that incorporates semiconductor materials within the core. These fibres are rich in optoelectronic functionality and offer extended transmission bands across the infrared spectral region so that their application potential is vast. Various fabrication methods have been developed to produce fibres with a range of unary and compound semiconductor core materials, which can be either amorphous or crystalline in form. This review discusses the main fabrication procedures and the infrared optical properties of the semiconductor fibres that have been fabricated to date, then takes a look at the future prospects of this exciting new technology.

  1. Erbium-doped nanoparticles in silica-based optical fibres

    CERN Document Server

    Blanc, Wilfried; Dussardier, Bernard; 10.1504/IJNT.2012.045350

    2012-01-01

    Developing of new rare-earth (RE)-doped optical fibres for power amplifiers and lasers requires continuous improvements in the fibre spectroscopic properties (like shape and width of the gain curve, optical quantum efficiency, resistance to spectral hole burning and photodarkening...). Silica glass as a host material for fibres has proved to be very attractive. However, some potential applications of RE-doped fibres suffer from limitations in terms of spectroscopic properties resulting from clustering or inappropriate local environment when doped into silica. To this aim, we present a new route to modify some spectroscopic properties of RE ions in silica-based fibres based on the incorporation of erbium ions in amorphous dielectric nanoparticles, grown in-situ in fibre preforms. By adding alkaline earth elements, in low concentration into silica, one can obtain a glass with an immiscibility gap. Then, phase separation occurs under an appropriate heat treatment. We investigated the role of three alkaline-earth...

  2. Flat Ge-doped optical fibres for food irradiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Noor, N. Mohd; Jusoh, M. A. [Department of Imaging, Faculty of Medicine and Health Sciences, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Razis, A. F. Abdull [Food Safety Research Centre, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Laboratory of UPM-MAKNA Cancer Research, Institute of Bioscience, Universiti Putra Malaysia, 43400 UPM Serdang, Selangor (Malaysia); Alawiah, A. [Faculty of Engineering and Technology, Multimedia University, 75450 Malacca (Malaysia); Bradley, D. A. [Department of Physics, University of Surrey, Guildford, Surrey GU2 7XH (United Kingdom); Department of Physics, University of Malaya, 50603 Kuala Lumpur (Malaysia)

    2015-04-24

    Exposing food to radiation can improve hygiene quality, germination control, retard sprouting, and enhance physical attributes of the food product. To provide for food safety, radiation dosimetry in irradiated food is required. Herein, fabricated germanium doped (Ge-doped) optical fibres have been used. The fibres have been irradiated using a gamma source irradiator, doses in the range 1 kGy to 10 kGy being delivered. Using Ge-doped optical fibres of variable size, type and dopant concentration, study has been made of linearity, reproducibility, and fading. The thermoluminescence (TL) yield of the fibres were obtained and compared. The fibres exhibit a linear dose response over the investigated range of doses, with mean reproducibility to within 2.69 % to 8.77 %, exceeding the dose range of all commercial dosimeters used in evaluating high doses for the food irradiation industry. TL fading of the Ge-doped flat fibres has been found to be < 13%.

  3. Infrared Supercontinuum Generation in Optical Fibres

    DEFF Research Database (Denmark)

    Dupont, Sune Vestergaard Lund

    with laser-like intensity is obtained, which otherwise is impossible without the use of more complicated equipment. Until recently, supercontinuum covering the mid-infrared was not possible due to absorption in the silica glass optical fibres are made of. In our project infrared transparent materials...... evolution has been investigated and also the mechanisms governing the pulse broadening. The generated infrared light has some crucial advantages compared to normal visible light. Infrared light can especially be used for spectroscopy, where the specific molecular absorptions are probed directly. This we...... have used for infrared microscopy where substance recognition is obtained in addition to magnification. Choosing a specific wavelength images showing only one substance can consequently be generated. More simple light sources are already used in such infrared microscopes to investigate tissue assays...

  4. Fibre Bragg Grating and Long Period Grating Sensors in Polymer Optical Fibres

    DEFF Research Database (Denmark)

    Bundalo, Ivan-Lazar

    of applications and pushing the limits. The first part of the work focuses on the fabrication of FBGs in polymer optical fibres. FBGs are a periodic perturbation of the refractive index of the optical fibre core which act as a wavelength specific reflector. The fibres used are made of Polymethyl methacrylate......, strain duration, increasing number of cycles, and it decreases with relaxation duration. For strains up to 0.9%, fast relaxing ΔΛfast range takes no less than 65% of the total strain range. Increase in ΔΛslow due to cyclic straining and relaxing seems to reach an equilibrium value, suggesting that ΔΛslow...... which translates the outside pressure into strain on the fibre. The transducer consisted of a 3Dprinted skeleton through which the fibre is pulled. A latex material is then wrapped around it and all the holes were sealed in order to prevent the air from leaking out. The pod transducer was tested...

  5. Optimal Extraction of Fibre Optic Spectroscopy

    CERN Document Server

    Sharp, R

    2009-01-01

    We report an optimal extraction methodology, for the reduction of multi-object fibre spectroscopy data, operating in the regime of tightly packed (and hence significantly overlapping) fibre profiles. The routine minimises crosstalk between adjacent fibres and statistically weights the extraction to reduce noise. As an example of the process we use simulations of the numerous modes of operation of the AAOmega fibre spectrograph and observational data from the SPIRAL Integral Field Unit at the Anglo-Australian Telescope.

  6. OPTICAL FIBRES: Photoinduced and thermal reactions involving hydrogen in high-germania-core optical fibres

    Science.gov (United States)

    Rybaltovskii, A. O.; Koltashev, V. V.; Medvedkov, O. I.; Rybaltovsky, A. A.; Sokolov, V. O.; Klyamkin, Semen N.; Plotnichenko, V. G.; Dianov, Evgenii M.

    2008-12-01

    We report a Raman scattering study of photoinduced and thermal reactions between H2 and germanosilicate optical fibres with 22 mol % and 97 mol % GeO2 in the core (F1 and F2, respectively) after H2 loading at 150 MPa (1500 atm). The mechanisms of photoreactions are investigated in a wide range of incident laser wavelengths (244, 333, 354, 361 and 514 nm). Thermal reactions are studied at 500 °C. The results indicate that the main mechanism behind the formation of hydrogen-containing defects with Raman bands at 700, 750, 2190, 3600 and 3680 cm-1 involves ≡Ge—O—Ge≡ or ≡Ge—O—Si≡ bond breaking and formation of hydride and hydroxyl species: =GeH2 (700, 750 cm-1), ≡Ge—H (2190 cm-1), ≡GeO—H (3600 cm-1) and ≡SiO—H (3680 cm-1). The key features of the reactions in the F1 and F2 fibres are analysed. In particular, photoinduced reactions give ≡Si—OH groups only in the F1 fibres, whereas the formation of germanium nanoclusters at a relatively low temperature (~500 °C) or ≡GeO—H and ≡Ge—H defects under 514-nm irradiation has only been observed in the F2 fibres.

  7. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet

    2015-01-01

    is the physical size of the device, allowing compatibility with current technology, while governing flexibility of the distal end of the endoscope based on the needs of the sensor. Polymer optical fibre (POF) presents a novel approach for endoscopic applications and has been positively discussed and compared...... in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...... and a higher resolution at small sizes. Furthermore, micro structured polymer optical fibres offer over 12 times the sensitivity of silica fibre. We present a polymer fibre Bragg grating ultrasound detector with a core diameter of 125 microns. We discuss the ultrasonic signals received and draw conclusions...

  8. Relativistic Corrections for Time and Frequency Transfer in Optical Fibres

    CERN Document Server

    Geršl, J; Wolf, P

    2016-01-01

    We derive relativistic corrections for one-way and two-way time and frequency transfer over optical fibres neglecting no terms that exceed 1 ps in time and $10^{-18}$ in fractional frequency, and estimate their magnitude in typical fibre links. We also provide estimates of the uncertainties in the evaluation of the relativistic corrections due to imperfect knowledge of parameters like the coordinates of the fibre and stations, Earth rotation, or thermal effects of the fibre index and length. The links between Teddington(UK) and Paris(F) as well as Braunschweig(D) and Paris(F), that are currently under construction, are studied as specific examples.

  9. Polarisation maintaining fibre with pure silica core and two depressed claddings for fibre optic gyroscope

    Science.gov (United States)

    Kurbatov, A. M.; Kurbatov, R. A.; Voloshin, V. V.; Vorob'ev, I. L.; Kolosovsky, A. O.

    2016-12-01

    Polarisation maintaining (PM) fibre is described with pure silica core and two depressed claddings for fibre optic gyro (FOG) sensing coil. Detailed mathematical simulation is presented by supermodes method, which is extremely necessary for such fibre. Simulation is fulfilled by frequency domain finite difference method (FDFDM), taking into account all details of realistic index profile with stress applying parts, while the leakage/bend loss occur in the region with complex index, surrounding the fibre. Cutoff and small bend loss are theoretically predicted and experimentally measured with excellent agreement between theory and experiment. Polarisation maintaining ability is measured in the form of conventional h-parameter (7.1·10-6 1/m) for 90-μm diameter fibre with birefringence value only 3.9·10-4.

  10. Effects of Polarization-Maintaining Fibre Degrading on Precision of Fibre Optic Gyroscopes in Radiation Environment

    Institute of Scientific and Technical Information of China (English)

    XIAO Wen; LIU De-Wen; LIU Yang; YI Xiao-Su; CONG Lin

    2008-01-01

    @@ In the space environment, the precision of fibre optic gyroscopes (FOGs) degrades because of space radiation.Photonic components of FOGs axe affected by radiation, especially the polaxization-maintaining (PM) fibre coil.In relation to the space radiation environment characteristic, we have carried out a series of radiation experiments on a PM fibre coil with 60Co radiation source at different dose rates. Based on the experimental results, the formula between the PM-fibre loss and radiation dose rata is built, and the relation between the precision of FOG and radiation dose is obtained accordingly. The results strongly show that the precision of our FOG degrades owing to the attenuation of the polarization-maintaining fibre, which provides theoretical foundation for the radiation-resistant design of the FOG.

  11. Quantifying uncertainty contributions for fibre optic power meter calibrations

    CSIR Research Space (South Africa)

    Nel, M

    2009-09-01

    Full Text Available A fibre optic power meter calibration has several uncertainty contributors associated with it. In order to assign a realistic uncertainty to the calibration result it is necessary to realistically estimate the magnitude of each uncertainty...

  12. A multi-purpose optical fibre sensor design for fibre reinforced composite materials

    Science.gov (United States)

    Fernando, G. F.; Liu, T.; Crosby, P.; Doyle, C.; Martin, A.; Brooks, D.; Ralph, B.; Badcock, R.

    1997-10-01

    This paper reports on the evaluation of a multi-functional extrinsic Fabry - Pérot optical fibre-based sensor design. The sensor was constructed using multimode and single mode optical fibres and a precision bore capillary tube. Fusion joints were used to secure the optical fibres into the capillary tube. The separation between the cleaved end-faces of the optical fibres defined the cavity length for the Fabry - Pérot sensor and the distance between the fusion joints defined the gauge length for this strain and temperature sensor. The sensor design was modified to: (i) monitor the progress of cure in an epoxy/amine resin system; (ii) detect the ingress of moisture in a cured epoxy/amine resin system; (iii) monitor the vibration characteristics of a pre- and post-impact damaged carbon fibre reinforced epoxy panel; and (iv) discriminate between strain and temperature measurements. The feasibility of using this type of sensor for cure monitoring, strain, temperature, residual stress measurements and damage detection in advanced fibre reinforced composites is demonstrated.

  13. Optoelectronic line transmission an introduction to fibre optics

    CERN Document Server

    Tricker, Raymond L

    2013-01-01

    Optoelectronic Line Transmission: An Introduction to Fibre Optics presents a basic introduction as well as a background reference manual on fiber optic transmission. The book discusses the basic principles of optical line transmission; the advantages and disadvantages of optical fibers and optoelectronic signalling; the practical applications of optoelectronics; and the future of optoelectronics. The text also describes the theories of optical line transmission; fibers and cables for optical transmission; transmitters including light-emitting diodes and lasers; and receivers including photodi

  14. Micro fibre optic flow checker for the medical analysis application.

    Science.gov (United States)

    Wang, Danping

    2007-01-01

    Two micro fibre optic flow checkers are presented in this paper. They are used for a medical analysis to control a solvent flow up to 1microl/min resolution. A fibre optic sensor as well as a hydraulic system are the principle components of these flow checkers. This paper describes the principle and the experiment setup. It gives the linearity, the repeatability and the stability results.

  15. RT Self-assembly of Silica Nanoparticles on Optical Fibres

    DEFF Research Database (Denmark)

    Canning, John; Lindoy, Lachlan; Huyang, George

    2013-01-01

    The room temperature deposition of self-assembling silica nanoparticles onto D-shaped optical fibres x201c;D-fibrex201d;), drawn from milled preforms fabricated by modified chemical vapor deposition, is studied and preliminary results reported here.......The room temperature deposition of self-assembling silica nanoparticles onto D-shaped optical fibres x201c;D-fibrex201d;), drawn from milled preforms fabricated by modified chemical vapor deposition, is studied and preliminary results reported here....

  16. Embedding of fibre optic sensors within flexible host

    OpenAIRE

    Ferraris, Eleonora; Van Gijseghem, Tim; Yan, Chunxiao; Van Hoe, Bram; Van Steenberge, Geert; Van Daele, Peter; Dubruel, Peter; Reynaerts, Dominiek

    2009-01-01

    This work deals with the establishment of a UV polymerisation procedure combined with moulding technology towards the development of a mass production technology for the fabrication of flexible polymers with optical fibres embedded. The concept is to provide an artificial sensing skin based on fibre optic sensors which can be applied to irregular or moveable surfaces for distributed pressure applications, as for instance in structural monitoring or rehabilitation. The selected polymers for su...

  17. A temperature-independent fibre-optic magnetic-field sensor using thin-core fibre tailored fibre Bragg grating

    Science.gov (United States)

    Tian, Qin; Feng, Zhongyao; Rong, Qiangzhou; Wan, Yun; Qiao, Xueguang; Hu, Manli; Yang, Hangzhou; Wang, Ruohui; Shao, Zhihua; Yang, Tingting

    2017-06-01

    A temperature-independent fibre-optic magnetic-field sensor is proposed and demonstrated experimentally. The device consists of a thin-core fibre (TCF) sandwiched in the upstream of a fibre Bragg grating (FBG). Because of the core-mismatch between the TCF and the single-mode fibre (SMF), the core mode is coupled to the cladding modes within the TCF cladding, and parts of them are recoupled back to the leading-in SMF by the downstream FBG. The cladding modes are sensitive to the ambient refractive index (RI), and therefore have the ability to respond to a RI change in the magnetic fluid determined by the ambient magnetic field. The intensities of the cladding-mode resonances are highly sensitive to the magnetic field change, while, in contrast, the resonance wavelengths always remain unchanged. This property can allow the sensor to act as a power-referenced reflection probe for magnetic field measurements.

  18. Analysis of Photosensitivity of Copolymer Optical Fibre Preform

    Institute of Scientific and Technical Information of China (English)

    MA Hui; LI Zeng-Chang; MING Hai; ZHANG Qi-Jin; TAM Hwa-Yaw; ZHANG Yong-Sheng; ZHANG Tao; WANG Pei; XIE Jian-Ping

    2004-01-01

    @@ The photosensitivity of copolymer optical fibre preform is analysed in comparison with the doped one. The effects of write conditions such as pump power and pump time have been studied. Then, the preform is drawn into single mode polymer optical fibre with core refractive index of 1.499, and core-cladding refractive-index difference of 0.008. Long-period birefringence gratings with period of 120um are fabricated in the fibre. The duty cycle is 50%, and the refractive index change in the exposed area is about 1 × 10-3.

  19. Deep ultraviolet laser micromachining of novel fibre optic devices

    Science.gov (United States)

    Li, J.; Dou, J.; Herman, P. R.; Fricke-Begemann, T.; Ihlemann, J.; Marowsky, G.

    2007-04-01

    A deep ultraviolet F2 laser, with output at 157-nm wavelength, has been adopted for micro-shaping the end facets of single and multi-mode silica optical fibres. The high energy 7.9-eV photons drive strong interactions in the wide-bandgap silica fibres to enable the fabrication of surface-relief microstructures with high spatial resolution and smooth surface morphology. Diffraction gratings, focusing lenses, and Mach-Zehnder interferometric structures have been micromachined onto the cleaved-fibre facets and optically characterized. F2-laser micromachining is shown to be a rapid and facile means for direct-writing of novel infibre photonic components.

  20. Fibre Optical Parametric Amplification in Defect Bragg Fibres with Zero Dispersion Slow Light Effect

    Institute of Scientific and Technical Information of China (English)

    XIAO Li; ZHANG Wei; HUANG Yi-Dong; PENG Jiang-De; ZHAO Hong; YANG Ke-Wu

    2008-01-01

    Nonfinearity enhancement by slow light effect and strong light confinement in defect Bragg fibres is demonstrated and analysed in applications of fibre optical parametric amplifiers. Broadband low group velocity and zero dispersion as well as the strong light confinement by band gap enhances the nonlinear coefficient up to more than one order than the conventional high nonlinear fibres.Moreover,the zero dispersion wavelength of coupled core mode can be designed arbitrarily,under which the phase-matching bandwidth of the nonlinear process can be extended.

  1. Fibre optic cables for the ALICE experiment

    CERN Multimedia

    Maximilien Brice

    2003-01-01

    These thin fibres will transmit the signal received in detectors at the ALICE experiment when it starts up with the LHC in 2008. The analogue signals produced in the detectors are first converted into digital pulse, which are transported in light down such fibres. Computers then read this digital signal to produce the final set of data.

  2. High Speed Fibre Optic Backbone LAN

    Science.gov (United States)

    Tanimoto, Masaaki; Hara, Shingo; Kajita, Yuji; Kashu, Fumitoshi; Ikeuchi, Masaru; Hagihara, Satoshi; Tsuzuki, Shinji

    1987-09-01

    Our firm has developed the SUMINET-4100 series, a fibre optic local area network (LAN), to serve the communications system trunk line needs for facilities, such as steel refineries, automobile plants and university campuses, that require large transmission capacity, and for the backbone networks used in intelligent building systems. The SUMINET-4100 series is already in service in various fields of application. Of the networks available in this series, the SUMINET-4150 has a trunk line speed of 128 Mbps and the multiplexer used for time division multiplexing (TDM) was enabled by designing an ECL-TTL gate array (3000 gates) based custom LSI. The synchronous, full-duplex V.24 and V.3.5 interfaces (SUMINET-2100) are provided for use with general purpose lines. And the IBM token ring network, the SUMINET-3200, designed for heterogeneous PCs and the Ethernet can all be connected to sub loops. Further, the IBM 3270 TCA and 5080 CADAM can be connected in the local mode. Interfaces are also provided for the NTT high-speed digital service, the digital PBX systems, and the Video CODEC system. The built-in loop monitor (LM) and network supervisory processor (NSP) provide management of loop utilization and send loop status signals to the host CPU's network configuration and control facility (NCCF). These built-in functions allow both the computer system and LAN to be managed from a single source at the host. This paper outlines features of the SUMINET-4150 and provides an example of its installation.

  3. Carbon laminates with RE doped optical fibre sensors

    Science.gov (United States)

    Miluski, Piotr; Kochanowicz, Marcin; Żmojda, Jacek; Silva, AbíLio P.; Reis, Paulo N. B.; Dorosz, Dominik

    2016-11-01

    A new type of luminescent optical fibre sensor for structural health monitoring of composite laminates (CFRP) is proposed. The Nd3+ doped multi-core doubleclad fibre incorporated in composite structure was used as a distributed temperature sensor. The change of luminescence intensity (Nd3+ ions) at the wavelength of 880 nm (4F3/2 → 4I9/2) and 1060 nm (4F3/2 → 4I11/2) was used for internal temperature monitoring. The special construction of optical fibre was used as it assures an efficient pumping mechanism and, at same time, it increases the measuring sensitivity. The linear response with relative sensitivity 0.015 K-1 was obtained for temperature range from 30 up to 75ºC. The manufacturing process of CFRP with embedded optical fibre sensor is also discussed.

  4. The role of quartz in the origin of optical activity on earth.

    Science.gov (United States)

    Evgenii, K; Wolfram, T

    2000-10-01

    A thorough analysis of literature data on distribution of right and left quartz in many locations on the surface of Earth indicates that quartz enantiomorph crystals are distributed in equal amounts in all locations. Therefore optically active quartz crystals of one or the other enantiomorph could not serve as the source of homochirality in the evolution of biosphere. Hence the calculation of a PVED based on published 'small excess of left quartz crystals' on Earth lacks a sound physical basis.

  5. ANALYSIS OF THE ACCURACY OF FIBRE-OPTIC STRAIN GAUGES

    Directory of Open Access Journals (Sweden)

    Dita Jiroutová

    2013-12-01

    Full Text Available In recent years, the field of structure monitoring has been making increasing use of systems based on fiber-optic technologies. Fiber-optic technology offers many advantages, including higher quality measurements, greater reliability, easier installation and maintenance, insensitivity to the environment (mainly to the electromagnetic field, corrosion resistance, safety in explosive and flammable environments, the possibility of long-term monitoring and lower cost per lifetime. We have used SOFO fibre-optic strain gauges to perform measurements to check the overall relative deformation of a real reinforced concrete structure. Long-term monitoring of the structure revealed that the measurement readings obtained from these fibre-optic strain gauges differed from each other. Greater attention was therefore paid to the calibration of the fibre-optic strain gauges, and to determining their measurement accuracy. The experimental results show that it is necessary to calibrate SOFO strain gauges before they are used, and to determine their calibration constant.

  6. Design of dual-mode optical fibres for the FTTH applications

    Science.gov (United States)

    Chen, Ming-Yang; Li, Yu-Rong; Zhang, Yin; Zhu, Yuan-Feng; Zhang, Yong-Kang; Zhou, Jun

    2011-01-01

    We present in this article a proposal and design for dual-mode optical fibres for fibre-to-the-home applications. High-order modes in the fibre can be effectively suppressed by the connection of the fibre with standard single-mode optical fibres at the two ends of the fibre. The alignment tolerance at the splicing process is presented. In particular, a low bending loss operation with low splice loss is demonstrated using the proposed technique.

  7. Infrared optical properties of $\\alpha$ quartz by molecular dynamics simulations

    CERN Document Server

    Gangemi, Fabrizio; Carati, Andrea; Maiocchi, Alberto; Galgani, Luigi

    2016-01-01

    This paper is concerned with theoretical estimates of the refractive--index curves for quartz, obtained by the Kubo formul\\ae\\ in the classical approximation, through MD simulations for the motions of the ions. Two objectives are considered. The first one is to understand the role of nonlinearities in situations where they are very large, as at the $\\alpha$--$\\beta$ structural phase transition. We show that on the one hand they don't play an essential role in connection with the form of the spectra in the infrared. On the other hand they play an essential role in introducing a chaoticity which involves a definite normal mode. This might explain why that mode is Raman active in the $\\alpha$ phase, but not in the $\\beta$ phase. The second objective concerns whether it is possible in a microscopic model to obtain normal mode frequencies, or peak frequencies in the optical spectra, that are in good agreement with the experimental data for quartz. Notwithstanding a lot of effort, we were unable to find results agr...

  8. Fibre Optic Sensors Using Adiabatically Tapered Single Mode Fibres

    Science.gov (United States)

    1994-02-01

    Membrane L!2ht Scurce ,ettor ([3Iar~nca] Property ImmobilIzatIon Optical Flba UAnpLl Dynamoc Range SeMfle Su art Arran ramene ,-t n i esuaorn Tlrrm...8217Solution-deposited thin films as passive and active light guides’, Applied Optics, 1972, 11, No 2, pp. 428-34. 397. Urbano , E. , H. Offenbacher, O.S...Chimica Acta, 1988, 208, pp. 53-8. 427. Wolfbeis, O.S., E. Urbano , ’A fluorimetric, heavy-metal-free method for the analysis of chlorine, bromine, and

  9. Fabrication of silicon based glass fibres for optical communication

    Indian Academy of Sciences (India)

    Vivek P Kude; R S Khairnar

    2004-02-01

    Silicon based glass fibres are fabricated by conventional fibre drawing process. First, preform fabrication is carried out by means of conventional MCVD technique by using various dopants such as SiCl4, GeCl4, POCl3, and FeCl3. The chemicals are used in such a way that step index single mode fibre can be drawn. The fibre drawing process consists of various steps such as heating the preform at elevated temperature, diameter monitor, primary and secondary coating, and ultra violet radiation curing. The fibres are then characterized for their geometrical and optical properties. The drawn fibre has diameter of core and cladding to be 8.3 m and 124.31 m, respectively whereas non-circularity is found to be 4.17% for core and 0.26% for cladding as seen from phase plot. Mode field diameter is found to be 8.9 m and 9.2 m using Peterman II and Gaussian method, respectively. The fabricated fibres showed the signal attenuation of 0.35 dB/km and 0.20 dB/km for 1310 nm and 1550 nm, respectively as measured by the optical time domain reflectometer (OTDR).

  10. Optical fibre grating refractometers for resin cure monitoring

    Science.gov (United States)

    Buggy, S. J.; Chehura, E.; James, S. W.; Tatam, R. P.

    2007-06-01

    The use of fibre grating refractometers as a means of monitoring the cure of a UV-cured epoxy resin is presented. The wavelength shift of the attenuation bands of a long period grating and the spectral response of a tilted fibre Bragg grating sensor were measured simultaneously during the cure of the resin and compared with measurements made using a fibre optic Fresnel-based refractometer. The results showed a good correlation (6 × 10-3 rius) and illustrate the potential of the techniques for non-invasive composite material cure monitoring.

  11. Remote actuation by optical power transmission in fibres

    Science.gov (United States)

    Avis, S. E.; Byron, K. C.

    1987-04-01

    Some preliminary experiments on the remote actuation of a servo-valve are described in which the power transmission medium is an optical fibre. Using a semiconductor laser or a Nd:YAG laser as the power source and silicon cells as the opto-electrical transducer, switching of the servo-valve has been observed at power levels of a few milliwatts over 800 m of fibre.

  12. Optical Fibre Sensors Using Graphene-Based Materials: A Review

    Science.gov (United States)

    Hernaez, Miguel; Zamarreño, Carlos R.; Melendi-Espina, Sonia; Bird, Liam R.; Mayes, Andrew G.; Arregui, Francisco J.

    2017-01-01

    Graphene and its derivatives have become the most explored materials since Novoselov and Geim (Nobel Prize winners for Physics in 2010) achieved its isolation in 2004. The exceptional properties of graphene have attracted the attention of the scientific community from different research fields, generating high impact not only in scientific journals, but also in general-interest newspapers. Optical fibre sensing is one of the many fields that can benefit from the use of these new materials, combining the amazing morphological, chemical, optical and electrical features of graphene with the advantages that optical fibre offers over other sensing strategies. In this document, a review of the current state of the art for optical fibre sensors based on graphene materials is presented. PMID:28098825

  13. Optical Fibre Sensors Using Graphene-Based Materials: A Review

    Directory of Open Access Journals (Sweden)

    Miguel Hernaez

    2017-01-01

    Full Text Available Graphene and its derivatives have become the most explored materials since Novoselov and Geim (Nobel Prize winners for Physics in 2010 achieved its isolation in 2004. The exceptional properties of graphene have attracted the attention of the scientific community from different research fields, generating high impact not only in scientific journals, but also in general-interest newspapers. Optical fibre sensing is one of the many fields that can benefit from the use of these new materials, combining the amazing morphological, chemical, optical and electrical features of graphene with the advantages that optical fibre offers over other sensing strategies. In this document, a review of the current state of the art for optical fibre sensors based on graphene materials is presented.

  14. Waveguidance by the photonic bandgap effect in optical fibres

    DEFF Research Database (Denmark)

    Broeng, Jes; Søndergaard, Thomas; Barkou, Stig Eigil;

    1999-01-01

    Photonic crystals form a new class of intriguing building blocks to be utilized in future optoelectronics and electromagnetics. One of the most exciting possiblilties offered by phtonic crystals is the realization of new types of electromagnetic waveguides. In the optical domain, the most mature...... technology for such photonic bandgap (PBG) waveguides is in optical fibre configurations. These new fibres can be classified in a fundamentally different way to all optical waveguides and possess radically different guiding properties due to PBG guidance, as opposed to guidance by total internal refelction...

  15. Secure Communication System Basedon Chaosin Optical Fibre

    Institute of Scientific and Technical Information of China (English)

    Pak L Chu; Fan Zhang; William Mak; Robust Lai

    2003-01-01

    @@ 1 Introduction Recently, there have been intense research activities on the study of synchronized chaos generated by fibre lasers [1] and its application to secure communication systems . So far, all studies concentrate on two aspects:[2].So far,all studies concentrate on two aspects:(1) the effect of the transmission channel between the transmitter and the receiver has been neglected, and (2)the chaos and the signal are carried by one wavelength.Both theoretical and experimental investigations make these two assumptions. In the experiments, the transmission fibre is invariably short, in the order of tens of metres. Hence its dispersion and nonlinear effects are negligible. The fibre laser responsible for the generation of chaos is often designed to lase at one wavelength only.

  16. Implementation and characterization of a fibre-optic colour sensor

    Science.gov (United States)

    Bajić, Jovan S.; Stupar, Dragan Z.; Dakić, Bojan M.; Manojlović, Lazo M.; Slankamenac, Miloš P.; Živanov, Miloš B.

    2014-09-01

    In this paper the implementation of a fibre-optic sensor for colour detection based on reflective colour sensing is proposed. The sensor consists of three plastic optical fibres emitting red, green and blue components and one optical fibre collecting light reflected from the object. Red, green and blue LEDs are excited at different frequencies. In this way detection of the reflected signal is achieved with only one photodetector and three bandpass filters. Bandpass filters are implemented as digital IIR (infinite impulse response) filters on the microcontroller. Results obtained from the proposed sensor are compared with commercial available colour sensors and the results are satisfactory. Analyses of the sensor performance both in RGB and HSV colour space are done. The proposed solution shows that in specific applications by using the HSV model the sensor can be used both as a colour and distance sensor.

  17. Optical Stabilizer Based on Optical Bistable Devices with All-Fibre Construction

    Institute of Scientific and Technical Information of China (English)

    LI Cheng; YE Hong-An; ZHAO Xue-Zeng; YANG Jiu-Ru; ZHANG Xin-Ming; LU Guo-Hui

    2004-01-01

    @@ We propose a fibre optical stabilizer constituted by a photoelectric-hybrid optical bistable device in which fibre Bragg grating is used as a light intensity modulator. The intensity noise-reducing ability is well improved through the method by employing two feed signals. As a result, the light intensity variation can be reduced to ~ 1/64.

  18. A microring multimode laser using hollow polymer optical fibre

    Indian Academy of Sciences (India)

    M Kailasnath; V P N Nampoori; P Radhakrishnan

    2010-11-01

    We report the observation of multimode laser operation at wavelengths corresponding to whispering-gallery modes from a freestanding microring cavity based on rhodamine B dye-doped PMMA hollow optical fibre. Cylindrical microcavities with diameters 155, 340 and 615 m were fabricated from a dye-doped hollow polymer optical fibre preform. An average mode spacing of 0.17 nm was observed for the 340 m cavity. This shows that the laser mode intensity distribution is concentrated on the outer edge of the cavity.

  19. Chalcogenide microstructured optical fibres for mid-IR applications

    Science.gov (United States)

    Trolès, Johann; Brilland, Laurent

    2017-01-01

    Compared to oxide-based glasses, vitreous materials composed of chalcogen elements (S, Se, Te) show large transparency windows in the infrared. Indeed, chalcogenide glasses can be transparent from the visible up to 12- 18 μm, depending on their compositions. In addition, chalcogenide glasses contain large polarisable atoms and external lone electron pairs that induce exceptional non-linear properties. Consequently, the non-linear properties can be 100 or 1000 times as high as the non-linearity of silica. An original way to obtain single-mode fibres is to design microstructured optical fibres (MOFs). These fibres present unique optical properties thanks to the high degree of freedom in the design of their geometrical structure. Various chalcogenide MOFs operating in the IR range have been elaborated in order to associate the high non-linear properties of these glasses with the original MOF properties. Indeed, chalcogenide MOFs might lead to new devices with unique optical properties in the mid-infrared domain, like multimode or endlessly single-mode transmission of light, small or large mode area fibres, highly birefringent fibres and non-linear properties for wavelength conversion or generation of supercontinuum sources. xml:lang="fr"

  20. Exhibition: Fibre optics, the future is at hand

    CERN Multimedia

    Anaïs Schaeffer

    2012-01-01

    Until 20 June, the Pont de la Machine in Geneva will host an exhibition on fibre optics, sponsored by SIG. CERN, a major user of this technology, was invited to take part with a presentation of some of its scintillating fibre detectors.   The CERN module, designed for the SIG's fibre optics exhibition. Visitors can discover a cosmic ray detector (on the right) and its oscilloscope (on the left), as well as one of the ALFA detector modules (at the back). The Services industriels genevois (SIG), who are in the process of deploying an optical fibre network in Geneva, have decided to showcase this technology with an exhibition entitled “Fibre optique – Le futur à portée de main.” The exhibition, which will be open to the public from 26 April to 20 June, is being held at the Espace ExpoSIG, at the Pont de la Machine in the centre of Geneva. “CERN’s Physics Department was approached by SIG at the start of this year to ...

  1. Optical Fibre Fabry-Perot Interferometers for Calorimetric Heat Transfer Gauges

    Science.gov (United States)

    1992-12-01

    The potential advantages of a fibre optic sensor for made with the "stem on the cndwall of a cascade heat transfer measurement are 0i) high spatial...from the laser diode source to the fibre- The Measurements of heat flux using. a fibre optic - intensitv referencing scheme outlined abov’ý was...reflections and parasitic optical cavities within the platinum thin film resisitance gauges fibre optic network Such reflections were reduced b% design

  2. A Continuously Tunable Erbium-Doped Fibre Laser Using Tunable Fibre Bragg Gratings and Optical Circulator

    Science.gov (United States)

    Liu, Peng; Yan, Feng-Ping; Li, Jian; Wang, Lin; Ning, Ti-Gang; Gong, Tao-Rong; Jian, Shui-Sheng

    2008-12-01

    A continuously tunable erbium-doped fibre laser (TEDFL) based on tunable fibre Bragger grating (TFBG) and a three-port optical circulator (OC) is proposed and demonstrated. The OC acts as a 100%-reflective mirror. A strain-induced uniform fibre Bragger grating (FBG) which functions as a partial-reflecting mirror is implemented in the linear cavity. By applying axial strain onto the TFBG, a continuously tunable lasing output can be realized. The wavelength tuning range covers approximately 7.00nm in C band (from 1543.6161 to 1550.3307nm). The side mode suppression ratio (SMSR) is better than 50 dB, and the 3 dB bandwidth of the laser is less than 0.01 nm. Moreover, an array waveguide grating (AWG) is inserted into the cavity for wavelength preselecting, and a 50 km transmission experiment was performed using our TEDFL at a 10Gb/s modulation rate.

  3. Miniaturised Optical Fibre Sensor for Dew Detection Inside Organ Pipes

    Directory of Open Access Journals (Sweden)

    Francesco Baldini

    2008-01-01

    Full Text Available A new optical sensor for the continuous monitoring of the dew formation inside organ pipes was designed. This aspect is particularly critical for the conservation of organs in unheated churches since the dew formation or the condensation on the pipe surfaces can contribute to many kinds of physical and chemical disruptive mechanisms. The working principle is based on the change in the reflectivity which is observed on the surface of the fibre tip, when a water layer is formed on its distal end. Intensity changes of the order of 35% were measured, following the formation of the water layer on the distal end of a 400/430 μm optical fibre. Long-term tests carried out placing the fibre tip inside the base of an in-house-made metallic foot of an organ pipe located in an external environment revealed the consistency of the proposed system.

  4. Deep ultraviolet laser micromachining of novel fibre optic devices

    Energy Technology Data Exchange (ETDEWEB)

    Li, J [The Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King' s College Road, Ontario M5S 3G4 (Canada); Dou, J [The Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King' s College Road, Ontario M5S 3G4 (Canada); Herman, P R [The Edward S. Rogers Sr. Department of Electrical and Computer Engineering, University of Toronto, 10 King' s College Road, Ontario M5S 3G4 (Canada); Fricke-Begemann, T [Laser-Laboratorium Goettingen e.V., D-37077 Goettingen (Germany); Ihlemann, J [Laser-Laboratorium Goettingen e.V., D-37077 Goettingen (Germany); Marowsky, G [Laser-Laboratorium Goettingen e.V., D-37077 Goettingen (Germany)

    2007-04-15

    A deep ultraviolet F{sub 2} laser, with output at 157-nm wavelength, has been adopted for micro-shaping the end facets of single and multi-mode silica optical fibres. The high energy 7.9-eV photons drive strong interactions in the wide-bandgap silica fibres to enable the fabrication of surface-relief microstructures with high spatial resolution and smooth surface morphology. Diffraction gratings, focusing lenses, and Mach-Zehnder interferometric structures have been micromachined onto the cleaved-fibre facets and optically characterized. F{sub 2}-laser micromachining is shown to be a rapid and facile means for direct-writing of novel infibre photonic components.

  5. Numerical modelling of multimode fibre-optic communication lines

    Energy Technology Data Exchange (ETDEWEB)

    Sidelnikov, O S; Fedoruk, M P [Novosibirsk State University, Novosibirsk (Russian Federation); Sygletos, S; Ferreira, F [Aston University, England, Birmingham, B4 7ET (United Kingdom)

    2016-01-31

    The results of numerical modelling of nonlinear propagation of an optical signal in multimode fibres with a small differential group delay are presented. It is found that the dependence of the error vector magnitude (EVM) on the differential group delay can be reduced by increasing the number of ADC samples per symbol in the numerical implementation of the differential group delay compensation algorithm in the receiver. The possibility of using multimode fibres with a small differential group delay for data transmission in modern digital communication systems is demonstrated. It is shown that with increasing number of modes the strong coupling regime provides a lower EVM level than the weak coupling one. (fibre-optic communication lines)

  6. FABRICATION AND APPLICATION OF NEARFIELD OPTICAL FIBRE PROBE

    Institute of Scientific and Technical Information of China (English)

    SUN JIA-LIN; XU JIAN-HUA; TIAN GUANG-YAN; GUo JI-HUA; ZHAO JUN; XIE AI-FANG; ZHANG ZE-BO

    2001-01-01

    In this paper, the fabrication of a large cone angle near-field optical fibre probe, using the two-step chemical etching method and bent probe, is introduced, and the controlling parameters of the coated Cr-Al film at the probe tip are presented. The scanning electron microscopy images display that the tip diameter of the uncoated large cone angle fibre probe obtained is less than 50nm, the cone angle over 90°, and the diameter of light aperture at the coated probe tip is less than 100nm. The measured results of the optical transmission efficiency for various probe tips show that the uncoated straight optical fibre probe, film-coated straight probe and film-coated bent probe are 3×10-1, 2×10-3, and l×10-4 times that of the flat fibre probe, respectively. In addition, the force images and near-field optical images of a standard sample are acquired using a large cone angle and film-coated bent probe.

  7. Fibre Optics In A Multi-Star Wideband Local Network

    Science.gov (United States)

    Fox, J. R.

    1983-08-01

    Early experience has been gained with the switched-star type of network in the Fibrevision cable TV trial at Milton Keynes, and British Telecom are progressing towards a full-scale multi-star wideband local network. This paper discusses both the present and future use of fibre optics in this type of network.

  8. Testing ultrafast two-photon spectral amplitudes via optical fibres.

    Science.gov (United States)

    Brida, G; Caricato, V; Chekhova, M V; Genovese, M; Gramegna, M; Iskhakov, T Sh

    2010-06-07

    We test two-dimensional TPSA of biphoton light emitted via ultrafast spontaneous parametric down-conversion (SPDC) using the effect of group-velocity dispersion in optical fibres. Further, we apply this technique to demonstrate the engineering of biphoton spectral properties by acting on the pump pulse shape.

  9. Optical fibre temperature sensor in the cryogenic range

    NARCIS (Netherlands)

    Bertrand, S.; Jalocha, A.; Tribillon, G.; Bouazaoui, M.; Rouhet, J.

    1996-01-01

    The realization of an optical fibre sensor applied to cryogenic temperature measurement in harsh environments is presented. The measurement principle is based on the analysis of the decay-time of the fluorescence emitted by special doped crystals, the excited state lifetimes of which are greatly dep

  10. Polymer Optical Fibre Sensors for Endoscopic Opto-Acoustic Imaging

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet;

    2015-01-01

    in existing publications. A great advantage can be obtained for endoscopy due to a small size and array potential to provide discrete imaging speed improvements. Optical fibre exhibits numerous advantages over conventional piezo-electric transducers, such as immunity from electromagnetic interference...

  11. Distributed fibre optic strain measurements on a driven pile

    Science.gov (United States)

    Woschitz, Helmut; Monsberger, Christoph; Hayden, Martin

    2016-05-01

    In civil engineering pile systems are used in unstable areas as a foundation of buildings or other structures. Among other parameters, the load capacity of the piles depends on their length. A better understanding of the mechanism of load-transfer to the soil would allow selective optimisation of the system. Thereby, the strain variations along the loaded pile are of major interest. In this paper, we report about a field trial using an optical backscatter reflectometer for distributed fibre-optic strain measurements along a driven pile. The most significant results gathered in a field trial with artificial pile loadings are presented. Calibration results show the performance of the fibre-optic system with variations in the strain-optic coefficient.

  12. Optical dating of single sand-sized grains of quartz: Sources of variability

    DEFF Research Database (Denmark)

    Duller, G.A.T.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    Optically stimulated luminescence (OSL) measurements have been made of over 3000 sand-sized grains of quartz. Analysis at this scale highlights the variability in the luminescence sensitivity and the dose saturation characteristics of individual quartz grains. Using a new instrument capable of me...... intensity, dose saturation characteristics and instrument uncertainty in equivalent dose calculation. (C) 2000 Elsevier Science Ltd. All rights reserved....

  13. Numerical modelling of multimode fibre-optic communication lines

    Science.gov (United States)

    Sidelnikov, O. S.; Sygletos, S.; Ferreira, F.; Fedoruk, M. P.

    2016-01-01

    The results of numerical modelling of nonlinear propagation of an optical signal in multimode fibres with a small differential group delay are presented. It is found that the dependence of the error vector magnitude (EVM) on the differential group delay can be reduced by increasing the number of ADC samples per symbol in the numerical implementation of the differential group delay compensation algorithm in the receiver. The possibility of using multimode fibres with a small differential group delay for data transmission in modern digital communication systems is demonstrated. It is shown that with increasing number of modes the strong coupling regime provides a lower EVM level than the weak coupling one.

  14. Control of the wavelength dependent thermo-optic coefficients in structured fibres

    DEFF Research Database (Denmark)

    Sørensen, Henrik Rokkjær; Canning, J.; Lægsgaard, Jesper

    2006-01-01

    By controlling the fibre geometry, the fraction of optical field within the holes and the inserted material of a photonic crystal fibre, we demonstrate that it is possible to engineer any arbitrary wavelength-dependent thermo-optic coefficient. The possibility of making a fibre with a zero...... temperature dependent thermo-optic coefficient, ideal for packaging of structured fibre gratings, is proposed and explored....

  15. High-speed signal processing using highly nonlinear optical fibres

    DEFF Research Database (Denmark)

    Peucheret, Christophe; Oxenløwe, Leif Katsuo; Mulvad, Hans Christian Hansen

    2009-01-01

    relying on the phase of the optical field. Topics covered include all-optical switching of 640 Gbit/s and 1.28 Tbit/s serial data, wavelength conversion at 640 Gbit/s, optical amplitude regeneration of differential phase shift keying (DPSK) signals, as well as midspan spectral inversion for differential 8......We review recent progress in all-optical signal processing techniques making use of conventional silica-based highly nonlinear fibres. In particular, we focus on recent demonstrations of ultra-fast processing at 640 Gbit/s and above, as well as on signal processing of novel modulation formats...

  16. Simple method for manufacturing and optical characterization of tapered optical fibres

    Science.gov (United States)

    Zakrzewski, A.; Pięta, A.; Patela, S.

    2016-12-01

    Photonic devices often use light delivered by a single-mode telecommunication fibre. However, as the diameter of the core of the optical fibre is of 10 microns, and the transverse dimensions of the photonic waveguides are usually micrometer or less, there is an issue of incompatibility. The problem may be solved by application of tapered optical fibres. For efficient light coupling, the taper should be prepared so as to create a beam of long focal length and small spot diameter in the focus. The article describes the design, fabrication and characterization of tapered optical fibres prepared with a fibre-optic fusion splicer. We modelled the tapers with FDTD method, for estimation of the influence of the tapered length and angle on the spot diameter and the focal length of an outgoing beam. We fabricated tapers from a standard single mode fibre by the Ericsson 995 PMfi- bre-optic fusion splicer. We planned the splicing technology so as to get the needed features of the beam. We planned a multistep fusion process, with optimized fusion current and fusion time. The experimental measurements of best tapered optical fibres were carried out by the knife-edge method.

  17. Programmable logic controller optical fibre sensor interface module

    Science.gov (United States)

    Allwood, Gary; Wild, Graham; Hinckley, Steven

    2011-12-01

    Most automated industrial processes use Distributed Control Systems (DCSs) or Programmable Logic Controllers (PLCs) for automated control. PLCs tend to be more common as they have much of the functionality of DCSs, although they are generally cheaper to install and maintain. PLCs in conjunction with a human machine interface form the basis of Supervisory Control And Data Acquisition (SCADA) systems, combined with communication infrastructure and Remote Terminal Units (RTUs). RTU's basically convert different sensor measurands in to digital data that is sent back to the PLC or supervisory system. Optical fibre sensors are becoming more common in industrial processes because of their many advantageous properties. Being small, lightweight, highly sensitive, and immune to electromagnetic interference, means they are an ideal solution for a variety of diverse sensing applications. Here, we have developed a PLC Optical Fibre Sensor Interface Module (OFSIM), in which an optical fibre is connected directly to the OFSIM located next to the PLC. The embedded fibre Bragg grating sensors, are highly sensitive and can detect a number of different measurands such as temperature, pressure and strain without the need for a power supply.

  18. Pyridine Vapors Detection by an Optical Fibre Sensor

    Directory of Open Access Journals (Sweden)

    Alberto Fernandez-Gutiérrez

    2008-02-01

    Full Text Available An optical fibre sensor has been implemented towards pyridine vapors detection;to achieve this, a novel vapochromic material has been used, which, in solid state, suffers achange in colour from blue to pink-white in presence of pyridine vapours. This complex isadded to a solution of PVC (Poly Vinyl Chloride, TBP (Tributylphosphate andtetrahydrofuran (THF, forming a plasticized matrix; by dip coating technique, the sensingmaterial is fixed onto a cleaved ended optical fibre. The fabrication process was optimizedin terms of number of dips and dipping speed, evaluating the final devices by dynamicrange. Employing a reflection set up, the absorbance spectra and changes in the reflectedoptical power of the sensors were registered to determine their response. A linear relationbetween optical power versus vapor concentration was obtained, with a detection limit of 1ppm (v/v.

  19. Flat knitting of a light emitting textile with optical fibres

    DEFF Research Database (Denmark)

    Heimdal, Elisabeth Jacobsen

    2009-01-01

    Knitted products have a flexibility that offers many attractive possibilities. Combined with technical fibres, this gives interesting and innovative possibilities. Many technical fibres and yarns has however properties such as high stiffness and brittleness which are difficult to process in the p......Knitted products have a flexibility that offers many attractive possibilities. Combined with technical fibres, this gives interesting and innovative possibilities. Many technical fibres and yarns has however properties such as high stiffness and brittleness which are difficult to process...... in the practice of weft knitting. This paper is about the experimental product development of a light radiating textile lamp in which optical fibres are used as the only illumination source. The lampshade is produced on an electronic flat knitting machine with special equipment suitable for the feeding of yarn...... of knitting production equipment and experimental work on a flat knitting machine at The Swedish School of Textiles, Boras, Sweden. Results show that the diamond shaped structure can be knitted in one piece with transparent monofilament yarns. Furthermore it also shows that difficulties occur when knitting...

  20. High resolution fibre optic length and extension measurement; Hochaufloesende faseroptische Laengen- und Ausdehnungsmessung

    Energy Technology Data Exchange (ETDEWEB)

    Doering, H. [Hochschule fuer Technik und Wirtschaft Mittweida (FH) (Germany)

    2007-07-01

    A monitoring system to observe the total length of an optical fibre integrated in building or environmental structures has been developed. The system is particularly suitable for fibres with a length of several meters to several kilometres. The system has been developed for optical fibres but is applicable to electrical cables as well. (orig.)

  1. Radiation hardness studies of high OH$^{-}$ quartz fibres for a hadronic forward calorimeter of the Compact Muon Solenoid experiment at the Large Hadron Collider

    CERN Document Server

    Dumanoglu, I; Kayis-Topaksu, A; Koca, N; Polatoz, A; Onengüt, G; Merlo, J P; Akchurin, N; Akgun, U; Ayan, S; Brücken, P; Schmidt, I; Onel, Y; Fenyvesi, A; Makónyi, K; Novák, D; Serin, M; Zeyrek, M T

    2002-01-01

    Darkening of various types of high OH/sup -/ fibres were studied by irradiating them with 500 MeV electrons. The transmission of Xe light was measured in situ in the 300-700 nm range. The induced attenuation at 450 nm is typically (1.52+or-0.15) dB/m for 100 Mrad absorbed dose. Two-parameter fits for darkening were presented. After irradiation the tensile strength remains essentially unchanged. For Polymicro quartz core fibres the tensile strength is typically (4.6+or-0.4) GPa. (6 refs).

  2. Evaluation of Fibre Lifetime in Optical Ground Wire Transmission Lines

    Science.gov (United States)

    Grunvalds, R.; Ciekurs, A.; Porins, J.; Supe, A.

    2017-06-01

    In the research, measurements of polarisation mode dispersion of two OPGWs (optical ground wire transmission lines), in total four fibres, have been carried out, and the expected lifetime of the infrastructure has been assessed on the basis of these measurements. The cables under consideration were installed in 1995 and 2011, respectively. Measurements have shown that polarisation mode dispersion values for cable installed in 1995 are four times higher than that for cable installed in 2011, which could mainly be explained by technological differences in fibre production and lower fibre polarisation mode dispersion requirements in 1995 due to lack of high-speed (over 10 Gbit/s) optical transmission systems. The calculation methodology of non-refusal work and refusal probabilities, using the measured polarisation mode dispersion parameters, is proposed in the paper. Based on reliability calculations, the expected lifetime is then predicted, showing that all measured fibres most likely will be operational within minimum theoretical service life of 25 years accepted by the industry.

  3. Magneto-optic sensor based on electrogyration compensation and single-quartz crystal

    Science.gov (United States)

    Li, Changsheng; Cui, He; Zhang, Xuan

    2016-11-01

    Magnetooptic sensor based on electrogyration compensation is proposed and experimentally demonstrated by using single quartz crystal. The sensing unit is composed of single quartz crystal and two polarizers. Quartz crystal exhibits magneto-optic, electro-optic and electrogyration effects, thus magneto-optic Faraday rotation angle can be compensated by the electrogyration angle induced by the compensating voltage applied to the crystal. The compensating voltage is sensitive to both the deviation angle between light beam and principal crystalline axis, and the azimuth angle of polarizer. The 50Hz ac magnetic flux density within 267Gs has been measured, the compensating voltage is 0.72V/Gs for a single quartz crystal with a length of 23mm. The proposed sensor has potential application to closed-loop measurement of magnetic field.

  4. Properties of Specialist Fibres and Bragg Gratings for Optical Fiber Sensors

    Directory of Open Access Journals (Sweden)

    John Canning

    2009-01-01

    Full Text Available The advent of optical fibres based on air holes running along their entirety opens up new directions in addressing various properties relevant to sensing, including the temperature/strain challenge of optical fibre sensors. This paper looks at the measurement challenges associated with temperature and strain, examines the potentially unique functionality structured fibre designs with and without gratings open up, and briefly describes some current research directions within conventional fibre and grating technologies.

  5. An Optical Fibre-Based Sensor for Respiratory Monitoring

    Directory of Open Access Journals (Sweden)

    Marek Krehel

    2014-07-01

    Full Text Available In this paper, a textile-based respiratory sensing system is presented. Highly flexible polymeric optical fibres (POFs that react to applied pressure were integrated into a carrier fabric to form a wearable sensing system. After the evaluation of different optical fibres, different setups were compared. To demonstrate the feasibility of such a wearable sensor, the setup featuring the best performance was placed on the human torso, and thus it was possible to measure the respiratory rate. Furthermore, we show that such a wearable system enables to keep track of the way of breathing (diaphragmatic, upper costal and mixed when the sensor is placed at different positions of the torso. A comparison of the results with the output of some commercial respiratory measurements devices confirmed the utility of such a monitoring device.

  6. Implications of information theory in optical fibre communications.

    Science.gov (United States)

    Agrell, Erik; Alvarado, Alex; Kschischang, Frank R

    2016-03-06

    Recent decades have witnessed steady improvements in our ability to harness the information-carrying capability of optical fibres. Will this process continue, or will progress eventually stall? Information theory predicts that all channels have a limited capacity depending on the available transmission resources, and thus it is inevitable that the pace of improvements will slow. However, information theory also provides insights into how transmission resources should, in principle, best be exploited, and thus may serve as a guide for where to look for better ways to squeeze more out of a precious resource. This tutorial paper reviews the basic concepts of information theory and their application in fibre-optic communications. © 2016 The Author(s).

  7. Fluorescent optical fibre chemosensor for the detection of mercury

    Science.gov (United States)

    Nguyen, T. Hien; Wren, Stephen P.; Sun, Tong; Grattan, Kenneth T. V.

    2016-11-01

    This work aims to develop a stable, compact and portable fibre optic sensing system which is capable of real time detection of the mercury ion (II), Hg2+. A novel fluorescent polymeric material for Hg2+ detection, based on a coumarin derivative (acting as the fluorophore) and an azathia crown ether moiety (acting as the mercury ion receptor), has been designed and synthesized. The material was covalently attached to the distal end of an optical fibre and exhibited a significant increase in fluorescence intensity in response to Hg2+ in the μM concentration range via a photoinduced electron transfer (PET) mechanism. The sensor has also demonstrated a high selectivity for Hg2+ over other metal ions. A washing protocol was identified for sensor regeneration, allowing the probe to be re-used. The approach developed in this work can also be used for the preparation of sensors for other heavy metals.

  8. Large-mode-area leaky optical fibre fabricated by MCVD

    OpenAIRE

    Dussardier, Bernard; Trzesien, Stanislaw; Ude, Michèle; Rastogi, Vipul; Kumar, Ajeet; Monnom, Gérard

    2008-01-01

    International audience; A large mode area single-mode optical fibre based on leaky mode filtering was prepared by MCVD. The cladding structure discriminates the fundamental mode from the higher order ones. A preliminary version has 25-µm core diameter and 0.11 numerical aperture. A Gaussian-like mode with 22-µm MFD is observed after 3-m propagation, in agreement with modeling.

  9. Hazard monitoring in mines using fibre optic sensors

    Science.gov (United States)

    Liu, T.; Wang, C.; Wei, Y.; Zhao, Y.; Huo, D.; Shang, Y.; Wang, Z.; Ning, Y.

    2009-10-01

    We report the development of a comprehensive safety monitoring solution for coal mines. A number of fibre optic sensors have been developed and deployed for safety monitoring of mine roof integrity and hazardous gases. The FOS-based mine hazard detection system offers unique advantages of intrinsic safety, multi-location and multi-parameter monitoring. They can be potentially used to build expert systems for mine hazard early detection and prevention.

  10. Miniaturised Optical Fibre Sensor for Dew Detection Inside Organ Pipes

    OpenAIRE

    Francesco Baldini; Riccardo Falciai; Andrea Azelio Mencaglia; Folco Senesi; Dario Camuffo; Antonio della Valle; Carl Johan Bergsten

    2008-01-01

    A new optical sensor for the continuous monitoring of the dew formation inside organ pipes was designed. This aspect is particularly critical for the conservation of organs in unheated churches since the dew formation or the condensation on the pipe surfaces can contribute to many kinds of physical and chemical disruptive mechanisms. The working principle is based on the change in the reflectivity which is observed on the surface of the fibre tip, when a water layer is formed on its distal en...

  11. Development of fibre-optic confocal microscopy for detection and diagnosis of dental caries.

    Science.gov (United States)

    Rousseau, C; Poland, S; Girkin, J M; Hall, A F; Whitters, C J

    2007-01-01

    We report on the development of a fibre-optics-based confocal imaging system for the detection and potential diagnosis of early dental caries. A novel optical instrument, capable of recording axial profiles through caries lesions using single-mode optical fibres, has been developed. The practical study illustrates that miniature confocal devices based around single-mode optical fibres may provide additional diagnostic information for the general dental practitioner.

  12. Distributed acoustic fibre optic sensors for condition monitoring of pipelines

    Science.gov (United States)

    Hussels, Maria-Teresa; Chruscicki, Sebastian; Habib, Abdelkarim; Krebber, Katerina

    2016-05-01

    Industrial piping systems are particularly relevant to public safety and the continuous availability of infrastructure. However, condition monitoring systems based on many discrete sensors are generally not well-suited for widespread piping systems due to considerable installation effort, while use of distributed fibre-optic sensors would reduce this effort to a minimum. Specifically distributed acoustic sensing (DAS) is employed for detection of third-party threats and leaks in oil and gas pipelines in recent years and can in principle also be applied to industrial plants. Further possible detection routes amenable by DAS that could identify damage prior to emission of medium are subject of a current project at BAM, which aims at qualifying distributed fibre optic methods such as DAS as a means for spatially continuous monitoring of industrial piping systems. Here, first tests on a short pipe are presented, where optical fibres were applied directly to the surface. An artificial signal was used to define suitable parameters of the measurement system and compare different ways of applying the sensor.

  13. Microstructured polymer optical fibre sensors for opto-acoustic endoscopy

    Science.gov (United States)

    Broadway, Christian; Gallego, Daniel; Pospori, Andreas; Zubel, Michal; Webb, David J.; Sugden, Kate; Carpintero, Guillermo; Lamela, Horacio

    2016-04-01

    Opto-acoustic imaging is a growing field of research in recent years, providing functional imaging of physiological biomarkers, such as the oxygenation of haemoglobin. Piezo electric transducers are the industry standard detector for ultrasonics, but their limited bandwidth, susceptibility to electromagnetic interference and their inversely proportional sensitivity to size all affect the detector performance. Sensors based on polymer optical fibres (POF) are immune to electromagnetic interference, have lower acoustic impedance and a reduced Young's Modulus compared to silica fibres. Furthermore, POF enables the possibility of a wideband sensor and a size appropriate to endoscopy. Micro-structured POF (mPOF) used in an interferometric detector has been shown to be an order of magnitude more sensitive than silica fibre at 1 MHz and 3 times more sensitive at 10 MHz. We present the first opto-acoustic measurements obtained using a 4.7mm PMMA mPOF Bragg grating with a fibre diameter of 130 μm and present the lateral directivity pattern of a PMMA mPOF FBG ultrasound sensor over a frequency range of 1-50 MHz. We discuss the impact of the pattern with respect to the targeted application and draw conclusions on how to mitigate the problems encountered.

  14. Connectorization of fibre Bragg grating sensors recorded in microstructured polymer optical fibre

    DEFF Research Database (Denmark)

    Abang, A.; Saez-Rodriguez, D.; Nielsen, Kristian

    2013-01-01

    We describe te production and characterization of FC/PC connectorised fibre Bragg grating sensors in polymer fibre. Sensors were recorded in few-moded and single mode microstructured fibre composed of poly (methyl methacrylate).......We describe te production and characterization of FC/PC connectorised fibre Bragg grating sensors in polymer fibre. Sensors were recorded in few-moded and single mode microstructured fibre composed of poly (methyl methacrylate)....

  15. A Continuously Tunable Erbium-Doped Fibre Laser Using Tunable Fibre Bragg Gratings and Optical Circulator

    Institute of Scientific and Technical Information of China (English)

    LIU Peng; YAN Feng-Ping; LI Jian; WANG Lin; NING Ti-Gang; GONG Tao-Rong; JIAN Shui-Sheng

    2008-01-01

    @@ A continuously tunable erbium-doped fibre laser (TEDFL) based on tunable fibre Bragger grating (TFBG) and a three-port optical circulator (OC) is proposed and demonstrated.The OC acts as a lO0%-refiective mirror.A strain-induced uniform fibre Bragger grating (FBG) which functions as a partial-refiecting mirror is implemented in the linear cavity.By applying axial strain onto the TFBG, a continuously tunable lasing output can be realized.The wavelength tuning range covers approximately 7.0Ohm in C band (from 1543.6161 to 1550.3307nm).The side mode suppression ratio (SMSR) is better than 50 dB, and the 3 dB bandwidth of the laser is less than 0.01 nm.Moreover, an array waveguide grating (AWG) is inserted into the cavity for wavelength preselecting, and a 50km transmission experiment was performed using our TEDFL at a 10 Gb/s modulation rate.

  16. Fibre optic pressure sensor using a microstructured POF

    Science.gov (United States)

    Arrizabalaga, Oskar; Durana, Gaizka; Aldabaldetreku, Gotzon; Zubia, Joseba

    2015-05-01

    Based on the attractive elasto-optic properties of single-mode microstructured polymer optical fibres (SM mPOFs) reported elsewhere,10 mode polarisation may be used as sensing probe for several parameters of interest like mechanical pressure. We report on a simplified detection scheme that does not require measuring the actual polarisation state of the light emerging from the mPOF. A polariser and a photodetector in a proper configuration are only required. The detected light intensity shows a high linearity with applied force to the mPOF.

  17. Fibre optic system for biochemical and microbiological sensing

    Energy Technology Data Exchange (ETDEWEB)

    Penwill, L A; Slater, J H; Hayes, N W; Tremlett, C J [Evanes Co Ltd, 4 and 5 Forde Court, Newton Abbot, Devon, TQ12 4AD (United Kingdom)

    2007-07-15

    This poster will discuss state-of-the-art fibre optic sensors based on evanescent wave technology emphasising chemophotonic sensors for biochemical reactions and microbe detection. Devices based on antibody specificity and unique DNA sequences will be described. The development of simple sensor devices with disposable single use sensor probes will be illustrated with a view to providing cost effective field based or point of care analysis of major themes such as hospital acquired infections or bioterrorism events. This presentation will discuss the nature and detection thresholds required, the optical detection techniques investigated, results of sensor trials and the potential for wider commercial application.

  18. Plastic optical fibre sensor for quality control in food industry

    Science.gov (United States)

    Novo, C.; Bilro, L.; Ferreira, R.; Alberto, N.; Antunes, P.; Leitão, C.; Nogueira, R.; Pinto, J. L.

    2013-05-01

    The present work addresses the need for new devices felt in the context of quality control, especially in the food industry. Due to the spectral dependence of the attenuation coefficient, a novel dual-parameter sensor for colour and refractive index was developed and tested. The sensor employs plastic optical fibres to measure the transmitted optical power in three measurement cells each with a different incident wavelength. The performance of the sensor was tested using several dyes at different concentrations and aqueous solutions of glycerine and ethanol. Results show that this technique allows the monitoring of refractive index and colour without cross-sensitivity.

  19. Multi-Functional Fibre-Optic Microwave Links

    DEFF Research Database (Denmark)

    Gliese, Ulrik Bo

    1998-01-01

    The multi-functionality of microwave links based on remote heterodyne detection of signals from a dual-frequency laser transmitter is discussed and experimentally demonstrated in this paper. Typically, direct detection in conjunction with optical intensity modulation is used to implement fibre......-optic microwave links. The resulting links are inherently transparent and mainly used for signal transmission. As opposed to direct detection links, remote heterodyne detection links can directly perform functionalities such as modulation, frequency conversion, and transparent signal recovery in addition...

  20. Simultaneous transfer of optical frequency and time over 306 km long-haul optical fibre link

    Science.gov (United States)

    Hucl, Vaclav; Cizek, Martin; Pravdova, Lenka; Rerucha, Simon; Hrabina, Jan; Mikel, Bretislav; Smotlacha, Vladimir; Vojtech, Josef; Lazar, Josef; Cip, Ondrej

    2016-12-01

    Optical fibre links for distributing optical frequencies and time stamps were researched and experimentally tested in the past fifteen years. They have been used mainly for stability comparison of experimental optical clocks. But recent development puts demands on a technology transfer from laboratory experiments to the real industry. The remote calibration of interrogators of Fibre Bragg Grating strain sensory networks is one of important examples. The first step of the adoption the time and frequency broadcasting should be the drop-out free long-term operation of this technology between research laboratories connected via long-haul fibre links. We present a 306 km long-haul optical fibre link between the cities of Prague and Brno in the Czech Republic where a coherent transfer of stable optical frequency and a stable time signal has been firstly demonstrated. The link between ISI CAS Brno and CESNET Prague uses an internet communication fibre where a window of 1540-1546 nm is dedicated for the coherent transfer and 1PPS signal. The link is equipped with 6 bidirectional EDFA amplifiers. The optical frequency standard based on the highly-coherent laser Koheras Adjustik working at 1540.5 nm and stabilized with a saturation absorption spectroscopy technique was used for the coherent wave transfer. The suppression of the Doppler shift induced by the optical fibre was based on an accoustooptical modulator with a servo-loop including a fast PID controller processing the beat-note frequency given by mixing of the Adjustik laser (Brno) and the reflected frequency of this laser from the far end of 306 km long-haul fibre link (Prague). We verified the Doppler shift suppression for the coherent wave with a measuring method analysing the transport delay of the 1PPS signal.

  1. Er doped oxide nanoparticles in silica based optical fibres

    CERN Document Server

    Blanc, Wilfried; Paul, M C

    2009-01-01

    Erbium doped materials are of great interest in optical telecommunications due to the Er3+ intra-4f emission at 1.54 ?m. Erbium doped fibre amplifiers (EDFA) were developed in silica glass because of the low losses at this wavelength and the reliability of this glass. Developments of new rare earth doped fibre amplifiers aim to control their spectroscopic properties including shape and width of the gain curve and optical quantum efficiency. Standard silica glass modifiers, such as aluminium, result in very good properties in current EDFA. However, for more drastic spectroscopic changes, more important modifications of the rare earth ions local environment are required. To address this aim, we present a fibre fabrication route creating rare earth doped calcia?silica or calcia?phosphosilica nanoparticles embedded in silica glass. By adding alkaline earth elements such as calcium, in low concentration, one can obtain a glass with an immisci- bility gap so that phase separation occurs with an appropriate heat tre...

  2. Step-index optical fibre drawn from 3D printed preforms

    CERN Document Server

    CooK, Kevin; Canning, John; Chartier, Loic; Athanaze, Tristan; Hossain, Md Arafat; Han, Chunyang; Comatti, Jade-Edouard; Luo, Yanhua; Peng, Gang-Ding

    2016-01-01

    Optical fibre is drawn from a dual-head 3D printer fabricated preform made of two optically transparent plastics with a high index core (NA ~ 0.25, V > 60). The asymmetry observed in the fibre arises from asymmetry in the 3D printing process. The highly multi-mode optical fibre has losses measured by cut-back as low as {\\alpha} ~ 0.44 dB/cm in the near IR.

  3. Monitoring Pre-Stressed Composites Using Optical Fibre Sensors

    Directory of Open Access Journals (Sweden)

    Sriram Krishnamurthy

    2016-05-01

    Full Text Available Residual stresses in fibre reinforced composites can give rise to a number of undesired effects such as loss of dimensional stability and premature fracture. Hence, there is significant merit in developing processing techniques to mitigate the development of residual stresses. However, tracking and quantifying the development of these fabrication-induced stresses in real-time using conventional non-destructive techniques is not straightforward. This article reports on the design and evaluation of a technique for manufacturing pre-stressed composite panels from unidirectional E-glass/epoxy prepregs. Here, the magnitude of the applied pre-stress was monitored using an integrated load-cell. The pre-stressing rig was based on a flat-bed design which enabled autoclave-based processing. A method was developed to end-tab the laminated prepregs prior to pre-stressing. The development of process-induced residual strain was monitored in-situ using embedded optical fibre sensors. Surface-mounted electrical resistance strain gauges were used to measure the strain when the composite was unloaded from the pre-stressing rig at room temperature. Four pre-stress levels were applied prior to processing the laminated preforms in an autoclave. The results showed that the application of a pre-stress of 108 MPa to a unidirectional [0]16 E-glass/913 epoxy preform, reduced the residual strain in the composite from −600 µε (conventional processing without pre-stress to approximately zero. A good correlation was observed between the data obtained from the surface-mounted electrical resistance strain gauge and the embedded optical fibre sensors. In addition to “neutralising” the residual stresses, superior axial orientation of the reinforcement can be obtained from pre-stressed composites. A subsequent publication will highlight the consequences of pres-stressing on fibre alignment, the tensile, flexural, compressive and fatigue performance of unidirectional E

  4. Optical Fibre Embedded in a Composite Laminated with Applications to Sensing

    Science.gov (United States)

    2000-09-29

    The possibility of using fibre optic instrumented plates in rehabilitation of civil structures was demonstrated, since strain measurements and...125-157, 1993. [4] W. W. Morey, G. Meltz, and W. H. Glenn, " Fibre optic bragg grating sensors", in Fiber Optic and Laser Sensors VII, in Proc. SPIE 1169, Boston, USA, pp. 98-107, 1989.

  5. Temperature-Insensitive Fibre-Optic Acceleration Sensor Based on Intensity-Referenced Fibre Bragg Gratings

    Institute of Scientific and Technical Information of China (English)

    SUN Li-Qun; DONG Bo; WANG Yong-Xin; Evan LALLY; WANG An-Bo

    2008-01-01

    A temperature-insensitive acceleration sensor using two fibre Bragg gratings (FBGs), based on reflection spectrum intensity modulation and optical power detection, is proposed and demonstrated. A cantilever beam is used to generate acceleration-induced axial strain along two sensing gratings, which are glued on the two opposite surfaces of the beam. Because the two gratings operate within the linear spectral range of a light source, formed by a thermally-tunable extrinsic Fabry-Perot optical filter, the intensity difference of the two reflections from the gratings is proportional to the acceleration applied. This eliminates the need for sophisticated wavelength interrogation of the gratings, and it also endows the sensor with immunity to temperature variation. Compared with a commercial micromachined accelerometer, the sensor is proven to be capable of accurately detecting acceleration.

  6. Long-term stability of fibre-optic transmission for multi-object spectroscopy

    CERN Document Server

    Sharp, R; Cannon, R D

    2012-01-01

    We present an analysis of the long-term stability of fibre-optic transmission properties for fibre optics in astronomy. Data from six years of operation of the AAOmega multi-object spectrograph at the Anglo-Australian Telescope is presented. We find no evidence for significant degradation in the bulk transmission properties of the 38 m optical fibre train. Significant losses (<20% relative, 4% absolute) are identified and associated with the end termination of the optical fibres in the focal plane. Improved monitoring and maintenance can rectify the majority of this performance degradation.

  7. Improved optical amplification using metamaterial based split ring structures in optical fibres

    Science.gov (United States)

    Prakash, Geetha; Nigam, Raaghvam; Das, Sovan; Chellappa, Sharath

    2016-04-01

    Optical fibres provide the best solutions for transmitting high speed, large amounts of data with good power efficiency. However such transmission would also need amplification for transmission over large distances. Erbium Doped Fibre Amplifiers(EDFAs) are currently being used for optical amplification. But good amplification is achievable with multiple stages and considerable length of EDFA fibres. In this paper we compare the use of Silver Split Ring Resonators(SRRs) , Gold Nano Rods and Silver Fishnet structures which give metamaterial properties to be used in optical fibres to give better amplification than EDFA based fibres. Metamaterials belong to a new class of materials with negative values for permittivity and permeability. Such materials would exhibit negative refractive index leading to these materials being called as left handed media.If such left handed media have an internal structure made of dimensions much smaller than the wavelength but sufficiently thick to exhibit bulk properties, using other optical domains such as plasmonics, it is possible to control light interactions and propagation. Artificial structures smaller than the wavelength of light can be used to enhance electric and magnetic fields. Surface plasmons can be excited on a metal and this can enhance the electric field at the surface. Our paper proposes the use of this phenomenon of achieving gain at optical frequencies by using SRRs, Fishnet structures , Nano Rods. We compare the performance of these structures and observe that they provide gain which is much more than that provided by EDFAs.

  8. Femtosecond laser induced refractive index structures in polymer optical fibre (POF) for sensing

    Science.gov (United States)

    Liang, S. J.; Scully, P. J.; Schille, J.; Vaughan, J.; Perrie, W.

    2009-10-01

    Techniques to directly write localised refractive index structures in polymer optical fibres (POF) are presented, using UV (400nm) ultrafast laser with pulse lengths of 100 fs to create in-fibre gratings for sensing. No doping is necessary for photosensitisation so commercially available POF is used. An in-fibre grating consisting of a 1.8 μm wide refractive index structure with a periodicity of 189 nm was demonstrated in single mode polymer fibre with optimised laser processing parameters.

  9. Humidity insensitive step-index polymer optical fibre Bragg grating sensors

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Fasano, Andrea; Stefani, Alessio

    2015-01-01

    We have fabricated and characterised a humidity insensitive step index(SI) polymer optical fibre(POF) Bragg grating sensors. The fibre was made based on the injection molding technique, which is an efficient method for fast, flexible and cost effective preparation of the fibre preform...... poly-methyl-methacrylate (PMMA) based SIPOFs. The fibre has a minimum loss of similar to 6dB/m at 770nm....

  10. Photoluminescence of an Yb3+/Al3+-codoped microstructured optical fibre

    Institute of Scientific and Technical Information of China (English)

    Xia Chang-Ming; Zhou Gui-Yao; Han Ying; Hou Lan-Tian

    2011-01-01

    An Yb3+/Al3+-codoped microstructured optical fibre is prepared based on photonic crystal fibre technology.The characteristic spectra of preforms and fibres are experimentally investigated.The results show that under a 971 nm excitation,besides the known infrared fluorescence luminescence around 1050 nm,a blue luminescence peak at 486 nm is obtained.Moreover,an unexpected emission peak at 730 nm is also observed.The photoluminescence mechanism of an Yb3+/Al3+-codoped microstructured optical fibre is discussed.The emission peak at 486 nm is attributed to the cooperative upconversion resulting from pairs of Yb3+ions,and the emission peak around 730 nm is ascribed to the stimulated Raman scattering because of nonlinear effects of microstructured optical fibre.The Yb3+/Al3+-codoped microstructured optical fibre is promising for varieties of applications from laser printing and optical recording to cancer treatments,such as photodynamic therapy.

  11. Optimising the separation of quartz and feldspar optically stimulated luminescence using pulsed excitation

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Jain, Mayank; Thomsen, Kristina Jørkov;

    2010-01-01

    In luminescence dating, the two most commonly used natural minerals, quartz and feldspar, are exposed to different dose rates in the natural environment, and so record different doses. The luminescence signals also have different stabilities. For accurate dosimetry, the signals from these two...... minerals must be separated, either by physical separation of the mineral grains, or by instrumental separation of the luminescence signals. The luminescence signals from quartz and feldspar have different luminescence lifetimes under pulsed optical stimulation. This difference in lifetime can be used...... to discriminate between the two signals from a mixed quartz-feldspar sample. The purpose of this study is to identify optimum measurement conditions for the best separation of quartz OSL from that of feldspar in a mixed sample using pulsed stimulation and time-resolved OSL. We integrate the signal from 5 μs after...

  12. Testing the reliability of ESR dating of optically exposed buried quartz sediments

    Energy Technology Data Exchange (ETDEWEB)

    Rink, W.J. [School of Geography and Geology, McMaster University, Hamilton, Ont., L8S 4K1 (Canada)], E-mail: rinkwj@mcmaster.ca; Bartoll, J.; Schwarcz, H.P. [School of Geography and Geology, McMaster University, Hamilton, Ont., L8S 4K1 (Canada); Shane, P. [Department of Geology, University of Auckland, Private Bag 92019, Auckland (New Zealand); Bar-Yosef, O. [Department of Anthropology, Harvard University, Cambridge, MA 02138 (United States)

    2007-11-15

    Optical dating of quartz by optically stimulated luminescence has a time range that is generally less than about 500 ka, due to relatively rapid saturation of the available luminescence defects in quartz. We test here a new method, electron spin resonance (ESR) optical dating of quartz, in which radiation-sensitive defects at aluminum and titanium atoms on silicon sites give rise to signals which can only be detected near liquid nitrogen temperature and which have a much higher capacity to absorb radiation dose before saturating than optical luminescence-detected signals. Our results show this method yields agreement with independent age control out to about 2.5 million years, extending here the dating range of optically exposed quartz in sediments in along-shore sediments (aeolian and waterlain) by a factor of about 5. Three sites in along-shore lacustrine and marine aeolian environments yielded very good agreement with independent age control. Details of single saturating exponential fitting in relation to agreement with expected burial doses and annealing of Al and Ti signals provide additional data to consider the best approaches to the dating method. Furthermore, we propose a new criterion for ESR optical dating: both the Al signal and Ti signal ages must agree to insure accurate burial ages. Moreover, when Al signal ages are lower than Ti signal ages, then the Al signal may be taken as the minimum burial age.

  13. Modern fibre-optic coherent lidars for remote sensing

    Science.gov (United States)

    Hill, Chris

    2015-10-01

    This paper surveys some growth areas in optical sensing that exploit near-IR coherent laser sources and fibreoptic hardware from the telecoms industry. Advances in component availability and performance are promising benefits in several military and commercial applications. Previous work has emphasised Doppler wind speed measurements and wind / turbulence profiling for air safety, with recent sharp increases in numbers of lidar units sold and installed, and with wider recognition that different lidar / radar wavebands can and should complement each other. These advances are also enabling fields such as microDoppler measurement of sub-wavelength vibrations and acoustic waves, including non-lineof- sight acoustic sensing in challenging environments. To shed light on these different applications we review some fundamentals of coherent detection, measurement probe volume, and parameter estimation - starting with familiar similarities and differences between "radar" and "laser radar". The consequences of changing the operating wavelength by three or four orders of magnitude - from millimetric or centimetric radar to a typical fibre-optic lidar working near 1.5 μm - need regular review, partly because of continuing advances in telecoms technology and computing. Modern fibre-optic lidars tend to be less complicated, more reliable, and cheaper than their predecessors; and they more closely obey the textbook principles of easily adjusted and aligned Gaussian beams. The behaviours of noises and signals, and the appropriate processing strategies, are as expected different for the different wavelengths and applications. For example, the effective probe volumes are easily varied (e.g. by translating a fibre facet) through six or eight orders of magnitude; as the average number of contributing scatterers varies, from >1, we should review any assumptions about "many" scatterers and Gaussian statistics. Finally, some much older but still relevant scientific work (by A G Bell, E H

  14. Optical fibre biosensors using enzymatic transducers to monitor glucose

    Science.gov (United States)

    Scully, P. J.; Betancor, L.; Bolyo, J.; Dzyadevych, S.; Guisan, J. M.; Fernández-Lafuente, R.; Jaffrezic-Renault, N.; Kuncová, G.; Matejec, V.; O'Kennedy, B.; Podrazky, O.; Rose, K.; Sasek, L.; Young, J. S.

    2007-10-01

    The construction and performance of a novel enzyme based optical sensor for in situ continuous monitoring of glucose in biotechnological production processes is presented. Sensitive optical coatings are formed from inorganic-organic hybrid polymers (ORMOCER®sORMOCER®: Trademark of Fraunhofer-Gesellschaft zur Förderung der angewandten Forschung e. V. in Germany.) combined with a flurophore (ruthenium complex) and an enzyme, and applied to lenses, declad polymer optical fibre (POF) and polymer clad silica fibre (PCS). The enzyme, glucose oxidase, catalyzes oxidization of glucose to gluconic acid by depleting oxygen. Oxygen consumption is determined by measuring the fluorescence lifetime of metal organic ruthenium complexes which are quenched by oxygen. The coatings developed were designed to adhere to glass and polymer surfaces, to be compatible with enzymes and ruthenium complexes, and were demonstrated both as double- and single-layer structures. The sensor response to gaseous oxygen, dissolved oxygen and dissolved glucose was measured via fluorescence lifetime changes. A best detection limit of 0.5% (vol) has been determined for gaseous O2 with selected ORMOCER® sensing layers. Glucose concentrations were measured to a detection limit of 0.1 mmol L-1 over a range up to 30 mmol L-1. The sensor was usable for 30 days in a bioreactor. The opto-electronic instrumentation and performance in laboratory bioreactors and in an industrial reactor are evaluated.

  15. Interferometry of binary stars using polymer optical fibres

    Science.gov (United States)

    Arregui, L.; Illarramendi, M. A.; Zubia, J.; Hueso, R.; Sánchez-Lavega, A.

    2017-07-01

    We show a laboratory experiment in which students can learn the use of interferometry as a valuable tool in astronomy. We detail experiments based on the use of the classic Michelson stellar interferometer able to reproduce the size of single stars and to characterize double star systems. Stellar sources, single and double, are reproduced by a laser light emerging from the circular end faces of one or two step-index polymer optical fibres. Light coming from the fibre end faces passes through two identical pinholes located on a lid covering the objective of a small telescope, thus producing interference fringes. The measurement of the fringe visibilities allows us to estimate both the diameters of the simulated stars and the separation between them, with errors lower than 18% for a range of light sources that can recreate the apparent size of the outer Solar System planets Uranus and Neptune and the binary properties of the Alpha Centauri system. The exercises here described illustrate the optical principles of spatial interferometry and can be integrated into courses on astronomy, optics or space science, with close interaction between theory and experiment.

  16. Photonic Crystal Fibres: A New Calss of Optical Waveguides

    DEFF Research Database (Denmark)

    Broeng, Jes; Mogilevstev, D.; Barkou, Stig Eigil

    1999-01-01

    . With an emphasis on the applicational aspects of the fibers, we study their single-mode operation, bending losses, and dispersion properties. While exhibiting certain unique properties, the high-index core photonic crystal fibres share many common features with conventional optical fibers, attributed...... and a central low-index ´structural defect along which the light is guided. The novel fiber has several unique features due to its different waveguidance mechanism, including remarkable dispersion properties and the potential to localize part of the guided mode in air regions. The results presented...

  17. Optical nanofibre integrated into an optical tweezers for particle manipulation, in situ fibre probing, and optical binding studies

    CERN Document Server

    Gusachenko, Ivan; Frawley, Mary C; Chormaic, Síle Nic

    2015-01-01

    Precise control of particle positioning is desirable in many optical propulsion and sorting applications. Here, we develop an integrated platform for particle manipulation consisting of a combined optical nanofibre and optical tweezers system. Individual silica microspheres were introduced to the nanofibre at arbitrary points using the optical tweezers, thereby producing pronounced dips in the fibre transmission. We show that such consistent and reversible transmission modulations depend on both particle and fibre diameter, and can be used as a reference point for in situ nanofibre or particle size measurement. Thence, we combine scanning electron microscope (SEM) size measurements with nanofibre transmission data to provide calibration for particle-based fibre assessment. This integrated optical platform provides a method for selective evanescent field manipulation of micron-sized particles and facilitates studies of optical binding and light-particle interaction dynamics.

  18. Annealing effects on strain and stress sensitivity of polymer optical fibre based sensors

    DEFF Research Database (Denmark)

    Pospori, A.; Marques, C. A. F.; Zubel, M. G.

    2016-01-01

    The annealing effects on strain and stress sensitivity of polymer optical fibre Bragg grating sensors after their photoinscription are investigated. PMMA optical fibre based Bragg grating sensors are first photo-inscribed and then they were placed into hot water for annealing. Strain, stress...... and force sensitivity measurements are taken before and after annealing. Parameters such as annealing time and annealing temperature are investigated. The change of the fibre diameter due to water absorption and the annealing process is also considered. The results show that annealing the polymer optical...... fibre tends to increase the strain, stress and force sensitivity of the photo-inscribed sensor....

  19. Supercontinuum Spectra generation in the single-mode optical fibre with Concave dispersion profile

    Institute of Scientific and Technical Information of China (English)

    Xu Wen-Cheng; Gao Jie-Li; Liang Zhan-Qiang; Chen Qiao-Hong; Liu Song-Hao

    2006-01-01

    In this paper,a new method is proposed to generate broad supercontinuum (SC) spectra in the single-mode optical fibre with concave dispersion profile.We numerically simulate pulse evolutions and discuss physics mechanism in detail for SC spectrum generation in the optical fibre with concave dispersion profile.Furthermore,general criteria are presented for specifying the shape of SC spectrum by introducing normalized parameters,which are related to the fibres and the initial pump pulses.The results show that the flat and broad SC spectra are indeed generated in our proposed optical fibre.

  20. OPTICAL FIBRE WITH HIGH NUMERICAL APERTURE, METHOD OF ITS PRODUCTION, AND USE THEREOF

    DEFF Research Database (Denmark)

    2003-01-01

    An article comprising an optical fibre, the fibre comprising at least one core surrounded by a first outer cladding region, the first outer cladding region being surrounded by a second outer cladding region, the first outer cladding region in the cross-section comprising a number of first outer...... an optical wavelength of light guided through the fibre when in use; a method of its production, and use thereof...

  1. The Symmetry of Optical Field in Photonic Crystal Fibre with Trigonal Symmetry

    Directory of Open Access Journals (Sweden)

    Ivan Turek

    2006-01-01

    Full Text Available Some photographs of intensity of optical field of a photonic crystal fibre are presented in the contribution. Presented photographs document that the symmetry of photonic crystal creating the cladding of fibre is manifested in the symmetry of distribution of the optical field intensity. In case when more modes are excited in the fibre the symmetry of the generated field can be different as the symmetry of the eventual modes. How the symmetry may be changed is illustrated by amodel example.

  2. Recent Improvement of Medical Optical Fibre Pressure and Temperature Sensors

    Directory of Open Access Journals (Sweden)

    Sven Poeggel

    2015-07-01

    Full Text Available This investigation describes a detailed analysis of the fabrication and testing of optical fibre pressure and temperature sensors (OFPTS. The optical sensor of this research is based on an extrinsic Fabry–Perot interferometer (EFPI with integrated fibre Bragg grating (FBG for simultaneous pressure and temperature measurements. The sensor is fabricated exclusively in glass and with a small diameter of 0.2 mm, making it suitable for volume-restricted bio-medical applications. Diaphragm shrinking techniques based on polishing, hydrofluoric (HF acid and femtosecond (FS laser micro-machining are described and analysed. The presented sensors were examined carefully and demonstrated a pressure sensitivity in the range of \\(s_p\\ = 2–10 \\(\\frac{\\text{nm}}{\\text{kPa}}\\ and a resolution of better than \\(\\Delta P\\ = 10 Pa protect (0.1 cm H\\(_2\\O. A static pressure test in 38 cmH\\(_2\\O shows no drift of the sensor in a six-day period. Additionally, a dynamic pressure analysis demonstrated that the OFPTS never exceeded a drift of more than 130 Pa (1.3 cm H\\(_2\\O in a 12-h measurement, carried out in a cardiovascular simulator. The temperature sensitivity is given by \\(k=10.7\\ \\(\\frac{\\text{pm}}{\\text{K}}\\, which results in a temperature resolution of better than \\(\\Delta T\\ = 0.1 K. Since the temperature sensing element is placed close to the pressure sensing element, the pressure sensor is insensitive to temperature changes.

  3. Ultrasensitive plasmonic sensing in air using optical fibre spectral combs

    Science.gov (United States)

    Caucheteur, Christophe; Guo, Tuan; Liu, Fu; Guan, Bai-Ou; Albert, Jacques

    2016-11-01

    Surface plasmon polaritons (SPP) can be excited on metal-coated optical fibres, enabling the accurate monitoring of refractive index changes. Configurations reported so far mainly operate in liquids but not in air because of a mismatch between permittivities of guided light modes and the surrounding medium. Here we demonstrate a plasmonic optical fibre platform that overcomes this limitation. The underpinning of our work is a grating architecture--a gold-coated highly tilted Bragg grating--that excites a spectral comb of narrowband-cladding modes with effective indices near 1.0 and below. Using conventional spectral interrogation, we measure shifts of the SPP-matched resonances in response to static atmospheric pressure changes. A dynamic experiment conducted using a laser lined-up with an SPP-matched resonance demonstrates the ability to detect an acoustic wave with a resolution of 10-8 refractive index unit (RIU). We believe that this configuration opens research directions for highly sensitive plasmonic sensing in gas.

  4. Fibre optic surface plasmon resonance sensor system designed for smartphones.

    Science.gov (United States)

    Bremer, Kort; Roth, Bernhard

    2015-06-29

    A fibre optic surface plasmon resonance (SPR) sensor system for smartphones is reported, for the first time. The sensor was fabricated by using an easy-to-implement silver coating technique and by polishing both ends of a 400 µm optical fibre to obtain 45° end-faces. For excitation and interrogation of the SPR sensor system the flash-light and camera at the back side of the smartphone were employed, respectively. Consequently, no external electrical components are required for the operation of the sensor system developed. In a first application example a refractive index sensor was realised. The performance of the SPR sensor system was demonstrated by using different volume concentrations of glycerol solution. A sensitivity of 5.96·10(-4) refractive index units (RIU)/pixel was obtained for a refractive index (RI) range from 1.33 to 1.36. In future implementations the reported sensor system could be integrated in a cover of a smartphone or used as a low-cost, portable point-of-care diagnostic platform. Consequently it offers the potential of monitoring a large variety of environmental or point-of-care parameters in combination with smartphones.

  5. Femtosecond fibre laser stabilisation to an optical frequency standard using a KTP electro-optic crystal

    Energy Technology Data Exchange (ETDEWEB)

    Nyushkov, B N [Novosibirsk State University, Novosibirsk (Russian Federation); Pivtsov, V S; Koliada, N A [Institute of Laser Physics, Siberian Branch, Russian Academy of Sciences, Novosibirsk (Russian Federation); Kaplun, A B; Meshalkin, A B [S.S. Kutateladze Institute of Heat Physics, Siberian Division of the Russian Academy of Sciences, Novosibirsk (Russian Federation)

    2015-05-31

    A miniature intracavity KTP-based electro-optic phase modulator has been developed which can be used for effective stabilisation of an optical frequency comb of a femtosecond erbiumdoped fibre laser to an optical frequency standard. The use of such an electro-optic modulator (EOM) has made it possible to extend the working frequency band of a phase-locked loop system for laser stabilisation to several hundred kilohertz. We demonstrate that the KTP-based EOM is sufficiently sensitive even at a small optical length, which allows it to be readily integrated into cavities of femtosecond fibre lasers with high mode frequency spacings (over 100 MHz). (extreme light fields and their applications)

  6. Performance emulation and parameter estimation for nonlinear fibre-optic links

    DEFF Research Database (Denmark)

    Piels, Molly; Porto da Silva, Edson; Zibar, Darko

    2016-01-01

    Fibre-optic communication systems, especially when operating in the nonlinear regime, generally do not perform exactly as theory would predict. A number of methods for data-based evaluation of nonlinear fibre-optic link parameters, both for accurate performance emulation and optimization...

  7. Polymer Optical Fibre Bragg Grating Humidity Sensor at 100ºC

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Fasano, Andrea; Markos, Christos

    2016-01-01

    We have demonstrated a polymer optical fibre Bragg grating humidity sensor that can be operated up to 100ºC. The sensor has been fabricated from a polycarbonate (PC) microstructured polymer optical fibre Bragg grating (mPOFBG). PC mPOFBG gave a relative humidity (RH) sensitivity of 6.95±0.83 pm...

  8. Fibre-optical techniques for measuring various properties of shock waves

    NARCIS (Netherlands)

    Prinse, W.C.; Esveld, R.J. van; Oostdam, R. van; Rooijen, M. van; Bouma, R.H.B.

    1999-01-01

    For the past years we have developed several optical techniques to measure properties of shock waves. The fibre optic probe (FOP) is developed to measure the shock-wave velocity and/or the detonation velocity inside an explosive. The space resolution can be as small as 0.5 mm. Single fibres are used

  9. Performance emulation and parameter estimation for nonlinear fibre-optic links

    DEFF Research Database (Denmark)

    Piels, Molly; Porto da Silva, Edson; Zibar, Darko;

    2016-01-01

    Fibre-optic communication systems, especially when operating in the nonlinear regime, generally do not perform exactly as theory would predict. A number of methods for data-based evaluation of nonlinear fibre-optic link parameters, both for accurate performance emulation and optimization, are rev...

  10. Annealing effects on strain and stress sensitivity of polymer optical fibre based sensors

    DEFF Research Database (Denmark)

    Pospori, A.; Marques, C. A. F.; Zubel, M. G.;

    2016-01-01

    The annealing effects on strain and stress sensitivity of polymer optical fibre Bragg grating sensors after their photoinscription are investigated. PMMA optical fibre based Bragg grating sensors are first photo-inscribed and then they were placed into hot water for annealing. Strain, stress and ...

  11. Polarization Drift Channel Model for Coherent Fibre-Optic Systems

    CERN Document Server

    Czegledi, Cristian B; Agrell, Erik; Johannisson, Pontus

    2015-01-01

    A theoretical framework is introduced to model the dynamical changes of the state of polarization during transmission in coherent fibre-optic systems. The model generalizes the one-dimensional phase noise random walk to higher dimensions, accounting for random polarization drifts. The model is described in the Jones, Stokes and real 4-dimensional formalisms, and the mapping between them is derived. Such a model will be increasingly important in simulating and optimizing future optical systems, which to a higher and higher degree rely on transmission and detection on both polarizations jointly using sophisticated digital signal processing. Such analysis cannot be carried out using the more rudimentary polarization drift models in use today, which only account for deterministic effects. The proposed polarization drift model is the first of its kind and will likely be useful in a wide-range of photonics applications where stochastic polarization fluctuation is an issue.

  12. An in vitro comparison of the ability of fibre-optic transillumination, visual inspection and radiographs to detect occlusal caries and evaluate lesion dept

    DEFF Research Database (Denmark)

    Ekstrand, K.R.; Côrtes, D.F.; Elias-Boneta, A.R.

    2000-01-01

    Occlusal caries, diagnosis, fibre-optic transillumination, bite-wing radiograph, visual inspection......Occlusal caries, diagnosis, fibre-optic transillumination, bite-wing radiograph, visual inspection...

  13. Understanding optically stimulated charge movement in quartz and feldspar using time-resolved measurements

    Energy Technology Data Exchange (ETDEWEB)

    Ankjaergaard, C.

    2010-02-15

    Thermoluminescence (TL) and optically stimulated luminescence (OSL) from quartz and feldspar are widely used in accident dosimetry and luminescence dating. In order to improve already existing methods or to develop new methods towards extending the current limits of the technique, it is important to understand the charge movement within these materials. Earlier studies have primarily focussed on examination of the trap behaviour; however, this only tells half of the story as OSL is a combination of charge stimulation and recombination. By using time-resolved OSL (TR-OSL), one can directly examine the recombination route(s), and thus obtain insight into the other half of the process involved in luminescence emission. This thesis studies the TR-OSL and optically stimulated phosphorescence signals from quartz and feldspars spanning several orders of magnitude in time (few ns to the seconds time scale) in order to identify various charge transport mechanisms in the different time regimes. The techniques employed are time-resolved OSL, continuous-wave OSL, TL, optically stimulated exo-electron (OSE) emission and time-resolved OSE. These different techniques are used in combination with variable thermal or optical stimulation energy. The thesis first delves into three main methodological developments, namely (i) research and development of the equipment for TR-OSL measurements, (ii) finding the best method for multiple-exponential analysis of a TR-OSL curve, and (iii) optimisation of the pulsing configuration for the best separation of quartz OSL from a mixed quarts-feldspar sample. It then proceeds to study the different charge transport mechanisms subsequent to an optical stimulation pulse in quartz and feldspars. The results obtained for quartz conclude that the main lifetime component in quartz represents an excited state lifetime of the recombination centre, and the more slowly decaying components on the millisecond to seconds time scale arise from charge recycling

  14. Real-time fibre optic radiation dosimeters for nuclear environment monitoring around thermonuclear reactors

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez, A. Fernandez; Brichard, B. [SCK .CEN, Belgian Nuclear Research Centre, Boeretang 200, B-2400 Mol (Belgium); O' Keeffe, S.; Fitzpatrick, C.; Lewis, E. [Electronic and Computer Engineering Department, University of Limerick, Limerick (Ireland); Vaille, J.-R.; Dusseau, L. [CEM2-Universite Montpellier II, cc083 place E. Bataillon, 34095 Montpellier Cedex 05 (France); Jackson, D.A. [School of Physical Sciences, University of Kent, Kent CT2 7NR (United Kingdom); Ravotti, F.; Glaser, M. [European Organization for Nuclear Research CERN, TS-LEA-RAD/PH-DT2-SD, CH-1211 Geneva 23 (Switzerland); El-Rabii, H. [Laboratoire de Combustion et de Detonique, ENSMA/CNRS, 1 av. Clement Ader, 86961 Chasseneuil-Futuroscope (France)], E-mail: afernand@sckcen.be

    2008-01-15

    The ability of fibre optic sensors to operate in hazardous nuclear environments and their intrinsic immunity to electro-magnetic interference make fibre optic sensing a very promising technology for the future ITER thermonuclear fusion reactor. In this paper, we evaluate fibre optic sensing technology for monitoring radiation dose in the vicinity of ITER during its operation and during the maintenance periods. First, the performance of an OSL dosimeter interrogated remotely using radiation tolerant optical fibres is evaluated both for real-time and integrating measurements for doses exceeding 100 Gy. We demonstrate its satisfactory operation in a mixed gamma neutron field. Second, we discuss the successful calibration of a new scintillating fibre optic radiation probe based on CsI(TI) crystals for operation in the dose-rate range 0.3-3000 mGy/h. The CsI(TI) crystal scintillator is mounted at the end of a 10-m long multimode fibre transceiver link to allow for remote deployment. The probes can detect and measure gamma dose rates ranging from 1 to 1000 mGy/h. Finally, we investigate the possible use of commercially available PMMA plastic optical fibres as on-line dosimeters up to 34 kGy. The dose measurement is derived from the radiation-induced attenuation in the optical fibre itself. A novel interrogation scheme based on a ratiometric technique is proposed for real-time dosimetry.

  15. Rare Earth Doped Silica Optical Fibre Sensors for Dosimetry in Medical and Technical Applications

    Directory of Open Access Journals (Sweden)

    N. Chiodini

    2014-01-01

    Full Text Available Radioluminescence optical fibre sensors are gaining importance since these devices are promising in several applications like high energy physics, particle tracking, real-time monitoring of radiation beams, and radioactive waste. Silica optical fibres play an important role thanks to their high radiation hardness. Moreover, rare earths may be incorporated to optimise the scintillation properties (emission spectrum, decay time according to the particular application. This makes doped silica optical fibres a very versatile tool for the detection of ionizing radiation in many contexts. Among the fields of application of optical fibre sensors, radiation therapy represents a driving force for the research and development of new devices. In this review the recent progresses in the development of rare earth doped silica fibres for dosimetry in the medical field are described. After a general description of advantages and challenges for the use of optical fibre based dosimeter during radiation therapy treatment and diagnostic irradiations, the features of the incorporation of rare earths in the silica matrix in order to prepare radioluminescent optical fibre sensors are presented and discussed. In the last part of this paper, recent results obtained by using cerium, europium, and ytterbium doped silica optical fibres in radiation therapy applications are reviewed.

  16. Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Lu Zenghai; Kasaragod, Deepa K; Matcher, Stephen J, E-mail: z.lu@sheffield.ac.uk, E-mail: s.j.matcher@sheffield.ac.uk [Department of Materials Science and Engineering, Kroto Research Institute, University of Sheffield, North Campus, Broad Lane, Sheffield, S3 7HQ (United Kingdom)

    2011-02-21

    We describe a fibre-based variable-incidence angle (VIA) polarization-sensitive swept-source optical coherence tomography (PS-SS-OCT) system to determine the 3D optical axis of birefringent biological tissues. Single-plane VIA-PS-OCT is also explored which requires measurement of the absolute fast-axis orientation. A state-of-the-art PS-SS-OCT system with some improvements both in hardware and software was used to determine the apparent optical birefringence of equine tendon for a number of different illumination directions. Polar and azimuthal angles of cut equine tendon were produced by the VIA method and compared with the nominal values. A quarter waveplate (QWP) and equine tendon were used as test targets to validate the fast-axis measurements using the system. Polar and azimuthal angles of cut equine tendon broadly agreed with the expected values within about 8% of the nominal values. A theoretical and experimental analysis of the effect of the sample arm fibre on determination of optical axis orientation using a proposed definition based on the orientation of the eigenpolarization ellipse experimentally confirms that this algorithm only works correctly for special settings of the sample arm fibre. A proposed algorithm based on the angle between Stokes vectors on the Poincare sphere is confirmed to work for all settings of the sample arm fibre. A calibration procedure is proposed to remove the sign ambiguity of the measured orientation and was confirmed experimentally by using the QWP.

  17. Photonic Crystal Fibres as the Transmission Medium for Future Optical Communication Systems

    DEFF Research Database (Denmark)

    Zsigri, Beata

    2006-01-01

    During this Ph.D. work, air-silica photonic crystal fibres(PCFs) have been investigated for telecommunication applications. PCFs have a complicated cladding structure, where air holes, running along the entire fibre length, ensure light guidance. Photonic crystal fibres can be classified into two......, and exploited for building fully functional, entirely PCF based optical transmission links and networks. The first 40 Gbit/s transmission over 5.6 km PCF with mid-span spectral inversion dispersion compensation realised in a highly nonlinear photonic crystal fibre is demonstrated. The first optical network...

  18. Macro-Bending Influence on Radiation Induced Attenuation Measurement in Optical Fibres

    CERN Document Server

    Guillermain, E; Ricci, D; Weinand, U

    2014-01-01

    Influence of the bending radius on the measurement of radiation induced attenuation in glass optical fibres is discussed in this paper. Radiation induced attenuation measured in two single-mode fibre types shows discrepancies when coiled around a low bending radius spool: the observed attenuation is lower than expected. A series of dedicated tests reveals that this invalid measurement is related to the displacement of the mode field towards the cladding when the fibre is bent with a low radius, and to the different radiation resistances of the core and cladding glasses. For irradiation tests of optical fibres, the spool radius should therefore be carefully chosen.

  19. Optically stimulated luminescence from quartz measured using the linear modulation technique

    DEFF Research Database (Denmark)

    Bulur, E.; Bøtter-Jensen, L.; Murray, A.S.

    2000-01-01

    The optically stimulated luminescence (OSL) from heated natural quartz has been investigated using the linear modulation technique (LMT), in which the excitation light intensity is increased linearly during stimulation. In contrast to conventional stimulation, which usually produces a monotonically...... stimulated component occurs at a shorter time. This allows the separation of the overlapping OSL components, which are assumed to originate from different traps. The LM-OSL curve from quartz shows an initial peak Followed by a broad one. Deconvolution using curve fitting has shown that the composite OSL...... curve from quartz can be approximated well by using a linear combination of first-order peaks. In addition to the three known components, i.e. fast, medium and slow components from continuous-wave-OSL studies, an additional slow component is also identified for the first time. The dose responses...

  20. Using soils for accident dosimetry: a preliminary study using optically stimulated luminescence from quartz

    DEFF Research Database (Denmark)

    Fujita, Hiroki; Jain, Mayank; Murray, Andrew S.

    2011-01-01

    The optimum conditions of preheat temperature, stimulation temperature, etc. in the single-aliquot regenerative optically stimulated luminescence (SAR OSL) method were examined specifically for measuring background dose in natural quartz extracted from soils collected around Tokai-mura in Japan....... The objective was to assess the potential of SAROSL dosimetry using soils for retrospective assessment of a radiation accident. Variation in dose with depth was also measured. The SAR data showed good reproducibility and dose recovery, and there was no evidence of fading of the quartz signal based on “delayed......, and no clear trend in dose depth profile was observed. From these results, we conclude that SAR OSL dosimetry using natural quartz extracted from soil could be used to evaluate the dose of an accident....

  1. Optical absorption in commercial single mode optical fibres for the LHC machine

    CERN Document Server

    Wijnands, T J; Kuhnhenn, J; Hoeffgen, S K; Weinand, U; TS

    2007-01-01

    The optical absorption of light at 1310 nm and 1550 nm in various commercially available Single Mode (SM) fibres samples has been studied. The absorption was measured as a function of dose, dose rate, temperature and light power. The samples were irradiated with gamma rays from a 60Co source and exposed to a complex radiation field from high energy physics. One fibre sample with an F-doped core exhibits extreme low absorption of light at 1310 nm during irradiation up to doses of at least 100 kGy.

  2. Understanding optically stimulated charge movement in quartz and feldspar using time-resolved measurements

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina

    to identify various charge transport mechanisms in the different time regimes. The techniques employed are time-resolved OSL, continuous-wave OSL, TL, optically stimulated exo-electron (OSE) emission and time-resolved OSE. These different techniques are used in combination with variable thermal or optical...... and the conduction band in determining charge transport. It is suggested that unlike quartz, the excited state lifetime does not play an important role in our measurements. Finally, it is shown that one of these routes favors production if a least fading signal (due to quantum mechanical tunnelling) in feldspars...... the TR-OSL and optically stimulated phosphorescence signals from quartz and feldspars spanning several orders of magnitude in time (few ns to the seconds time scale) in order to identify various charge transport mechanisms in the different time regimes. The techniques employed are time-resolved OSL...

  3. Humidity insensitive step-index polymer optical fibre Bragg grating sensors

    DEFF Research Database (Denmark)

    Woyessa, Getinet; Fasano, Andrea; Stefani, Alessio;

    2015-01-01

    We have fabricated and characterised a humidity insensitive step index(SI) polymer optical fibre(POF) Bragg grating sensors. The fibre was made based on the injection molding technique, which is an efficient method for fast, flexible and cost effective preparation of the fibre preform. The fabric......We have fabricated and characterised a humidity insensitive step index(SI) polymer optical fibre(POF) Bragg grating sensors. The fibre was made based on the injection molding technique, which is an efficient method for fast, flexible and cost effective preparation of the fibre preform....... The fabricated SIPOF has a core made from TOPAS with a glass transition temperature of 134 degrees C and a cladding from ZEONEX with a glass transition temperature of 138 degrees C. The main advantages of the proposed SIPOF are the low water absorption and good chemical resistance compared to the conventional...

  4. Pulse Compression And Raman Amplification In Optical Fibres

    Science.gov (United States)

    Byron, Kevin C.

    1988-06-01

    Experimental and theoretical investigations on Raman amplification in fibres have been carried out and simultaneous amplification and pulse compression observed. With a fibre design optimised for amplification high gain may be obtained at practical pump power levels.

  5. Stabilisation of a fibre frequency synthesiser using acousto-optical and electro-optical modulators

    Science.gov (United States)

    Koliada, N. A.; Nyushkov, B. N.; Pivtsov, V. S.; Dychkov, A. S.; Farnosov, S. A.; Denisov, V. I.; Bagayev, S. N.

    2016-12-01

    A fibre-optic frequency synthesiser is developed that is stabilised to the optical frequency standard based on molecular iodine ({\\text{Nd : YAG/I}}2). The possibility of transferring stability of the optical frequency standard to other optical frequencies in the IR range 1 - 2 \\unicode{956}{\\text{m}} and to the RF range by using synthesiser phase-locked loops (PLLs) with acousto-optical and electro-optical modulators is experimentally demonstrated. The additive instability introduced into the optical frequency comb of the synthesiser (which arises due to PLL residual random errors) is several orders less than the intrinsic instability of the reference optical frequency standard employed (i.e., is noticeably less than 1 × 10-13 for 1 {\\text{s}} and 5 × 10-15 for 1000 {\\text{s}}).

  6. Access Protocol For An Industrial Optical Fibre LAN

    Science.gov (United States)

    Senior, John M.; Walker, William M.; Ryley, Alan

    1987-09-01

    A structure for OSI levels 1 and 2 of a local area network suitable for use in a variety of industrial environments is reported. It is intended that the LAN will utilise optical fibre technology at the physical level and a hybrid of dynamically optimisable token passing and CSMA/CD techniques at the data link (IEEE 802 medium access control - logical link control) level. An intelligent token passing algorithm is employed which dynamically allocates tokens according to the known upper limits on the requirements of each device. In addition a system of stochastic tokens is used to increase efficiency when the stochastic traffic is significant. The protocol also allows user-defined priority systems to be employed and is suitable for distributed or centralised implementation. The results of computer simulated performance characteristics for the protocol using a star-ring topology are reported which demonstrate its ability to perform efficiently with the device and traffic loads anticipated within an industrial environment.

  7. Toluene optical fibre sensor based on air microcavity in PDMS

    Science.gov (United States)

    Kacik, Daniel; Martincek, Ivan

    2017-03-01

    We prepared and demonstrated a compact, simple-to-fabricate, air microcavity in polydimethylsiloxane (PDMS) placed at the end of a single-mode optical fibre. This microcavity creates a Fabry-Perot interferometer sensor able to measure concentrations of toluene vapour in air. Operation of the sensor is provided by diffusion of the toluene vapour to the PDMS, and the consequent extension of length d of the air microcavity in PDMS. The sensor response for the presence of vapours is fast and occurs within a few seconds. By using the prepared sensor toluene vapour concentration in air can be measured in the range from about 0.833 g.m-3 to saturation, with better sensitivity than 0.15 nm/g.m-3 up to maximal sensitivity 1.4 nm/g.m-3 at around concentration 100 g.m-3 in time 5 s.

  8. Multimode laser emission from dye-doped hollow polymer optical fibre

    Indian Academy of Sciences (India)

    C L Linslal; Jaison Peter; S Mathew; M Kailasnath

    2014-02-01

    Well-resolved multimode laser emission was observed for the first time from a freestanding microring cavity based on Rhodamine B dye-doped hollow polymer optical fibre by transverse pumping. Fibres with different diameters such as 180, 460, 640 and 800 m were fabricated from a dye-doped hollow polymer preform. A blueshift in the mode structure was observed with decrease in fibre diameter leading to wide range tunability of the laser emission.

  9. Effect of temperature on the active properties of erbium-doped optical fibres

    Energy Technology Data Exchange (ETDEWEB)

    Kotov, L V [Moscow Institute of Physics and Technology (State University), Dolgoprudnyi, Moscow Region (Russian Federation); Ignat' ev, A D [FORC - Photonics group, Moscow (Russian Federation); Bubnov, M M; Likhachev, M E [Fiber Optics Research Center, Russian Academy of Sciences, Moscow (Russian Federation)

    2016-03-31

    We have studied the effect of heating on the performance of erbium-doped fibre based devices and determined temperaturedependent absorption and emission cross sections of the erbium ion in silica glass. The results demonstrate that heating of fibres in claddingpumped high-power (∼100 W) erbium-doped fibre lasers causes no significant decrease in their efficiency. In contrast, superluminescent sources operating in the long-wavelength region (1565 – 1610 nm) are extremely sensitive to temperature changes. (fiber optics)

  10. A proposed fibre optic time domain optical coherence tomography system using a micro-photonic stationary optical delay line

    Science.gov (United States)

    Jansz, Paul Vernon; Wild, Graham; Hinckley, Steven

    2008-04-01

    Conventional time domain Optical Coherence Tomography (OCT) relies on a reference Optical Delay Line (ODL). These reference ODLs require the physical movement of a mirror to scan a given depth range. This movement results in instrument degradation. We propose a new optical fibre based time domain OCT system that makes use of a micro-photonic structure as a stationary ODL. The proposed system uses an in-fibre interferometer, either a Michelson or a Mach-Zhender. The reference ODL makes use of a collimator to expand the light from the optical fibre. This is them expanded in one dimension via planar optics, that is, a cylindrical lens based telescope, using a concave and convex lens. The expanded beam is them passed through a transmissive Spatial Light Modulator (SLM), specifically a liquid crystal light valve used as an optical switch. Light is then reflected back through the system off the micro-photonic structure. The micro-photonic structure is a one dimensional array of stagged mirror steps, called a Stepped Mirror Structure (SMS). The system enables the selection of discrete optical delay lengths. The proposed ODL is capable of depth hoping and multicasting. We discuss the fabrication of the SMS, which consists of eight steps, each approximately 150 μm high. A change in notch frequency using an in-fibre Mach Zhender interferometer was used to gauge the average step height. The results gave an average step height of 146 μm.

  11. Shock experiments on pre-heated alpha- and beta-quartz: 1. Optical and density data

    Science.gov (United States)

    Langenhorst, Falko; Deutsch, Alexander

    1994-07-01

    Discs of single crystal quartz, unheated, and pre-heated to 275 C and 540 C (i.e., alpha-quartz) and 630 C (i.e., beta-quartz) were experimentally shocked to pressures ranging from 20 to 40 GPa, with the shock front propagating parallel to either (10-10) or (0001). Refractive indices, density and the orientation of planar deformation features (PDFs) were determined on the recovered quartz samples. Refractive indices of pre-heated quartz are unaffected up to 25 GPa but density starts to decrease slightly up to this pressure. Above 25 GPa, pre-heating causes drastic variations: Refractive indices and birefringence of quartz shocked at ambient temperature decrease continuously, until complete isotropization is reached at 35 GPa. In quartz shocked at 630 C, refractivity drops discontinuously in the interval from 25 to 26 GPa, and complete transformation to diaplectic glass is reached at 26 GPa. Density follows the trends demonstrated by the optical parameters, with higher pre-shock temperatures yielding lower density at a given shock pressure. These results indicate that the threshold pressure for the onset of transformation to diaplectic quartz glass is largely temperature-invariant, lying at 25 GPa, whereas the pressure limit for complete transformation decreases with increasing pre-shock temperature from approximately equal 35 to approximately equal 26 GPa. Quartz shocked parallel to (0001) always has a higher density and refractivity than that shocked parallel to (10-10), indicating a significant influence of the structural anisotropy. This is also evident from the distribution of PDF orientations. Pressures greater than or equal 25 GPa cause, in quartz shocked parallel to (10-10), PDFs that are predominantly oriented parallel to set of (10-12) planes, while quartz shocked to the same pressures but parallel to (0001) contains almost exclusively PDFs parallel to set of (10-13) planes. PDF orientations in quartz shocked at ambient temperature parallel to (10-10) show

  12. Self-Induced Optical Rotation of Solitons in a Chiral Fibre

    Institute of Scientific and Technical Information of China (English)

    李俊庆; 李社; 王晓鸥; 郑仰东; 李淳飞

    2004-01-01

    From Maxwell's equations and macroscopic polarization, we obtain the wave equations describing the propagation of strong light in an isotopic chiral fibre with weak spatial dispersion. By considering the possible nonlinear and dispersive effects, the nonlinear Schrodinger equations for the left- and right-circularly polarized components are derived. The mechanism to form the chiral optical solitons is discussed. The self-induced optical rotation of solitons in the chiral fibre is emphasized. An all-optical switch is proposed.

  13. Air-structured optical fibre drawn from a 3D-printed preform

    CERN Document Server

    Cook, Kevin; Leon-Saval, Sergio; Reid, Zane; Hossain, Md Arafat; Comatti, Jade-Edouard; Luo, Yanhua; Peng, Gang-Ding

    2016-01-01

    A structured optical fibre is drawn from a 3D-printed structured preform. Preforms containing a single ring of holes around the core are fabricated using filament made from a modified butadiene polymer. More broadly, 3D printers capable of processing soft glasses, silica and other materials are likely to come on line in the not-so distant future. 3D printing of optical preforms signals a new milestone in optical fibre manufacture.

  14. Two-dimensional refractive index and birefringence profiles of a graded index bent optical fibre

    Science.gov (United States)

    Ramadan, W. A.; Wahba, H. H.; Shams El-Din, M. A.

    2017-07-01

    A theory to recover refractive index profile of the bent graded index (GRIN) optical fibre, in core region, is proposed. This theory is applied to the bent GRIN optical fibre when it is located orthogonal in the light path of the object arm in digital holographic phase shifting interferometer; like Mach-Zehnder interferometer. In the experiment, the fibre is bent with two different bending radii and fixed on a microscope slide keeping it immersed in matching liquid. The produced phase shifted holograms, with the presence of the fibre, are recorded using an attached CCD camera. Two different processes controlling the index profile shape of the bent GRIN optical fibre are assumed. In the first process, a linear index variation is evolved from stresses in the direction of the bent radius. In the second one, there is a release of these stresses near the fibre surface, which depends on the fibre's radius. This will affect the outer free surface of the cladding. Based on these assumptions, we are able to construct the index profile in two dimensions normal to the optical axis. We propose two functions to describe the refractive index profiles in cladding and the core regions of the bent GRIN optical fibre. The recorded phase shifted holograms are combined, reconstructed and analyzed to get the phase map of the bent GRIN optical fibre. Comparing the extracted optical phase differences with the calculated ones, a good agreement between them is found. This means that the used two dimensional proposed functions, which are describing cladding and the core indices profiles, are the most proper in this situation. Thus, we are able to determine a realistic induced birefringence profile inside the fibre which is generated by a bending operation, not only in the cladding but also in graded index core region as well.

  15. EDITORIAL: The 20th International Conference on Optical Fibre Sensors, OFS-20 The 20th International Conference on Optical Fibre Sensors, OFS-20

    Science.gov (United States)

    Culshaw, Brian; Ecke, Wolfgang; Jones, Julian; Tatam, Ralph; Willsch, Reinhardt

    2010-09-01

    Welcome to our special issue on fibre optic sensors. Fibre optic sensors were first suggested in the patent literature in the mid 1960s as an innovative means for making measurements. This proposed a surface finish measurement tool with high precision and resulted in an instrument that remains available today. Much has happened since, with significant innovation in the techniques through which light propagating whilst guided in a fibre can be unambiguously, repeatedly and predictably modulated in response to an external phenomenon. The technique offers not only the precision mentioned earlier but also inherent electromagnetic immunity, the capability to sense at long distances, light weight, small size and a multiplicity of network architectures, all of which can be interrogated from a single point. Even so, fibre sensors is a niche technology, attractive only when its very special features offer substantial user benefit. There are, however, many such niches exemplified in the electrical power supply industry, in gyroscopes for navigational instruments, in hydrophones and geophones. Then there are the distributed sensing architectures that enable useful measurements of pressure, strain and temperature fields affecting the optical properties of the fibre itself to map these parameter fields as a function of position along lengths of fibre to many tens of kilometres. The fibre sensing concept spawned its own research community, and the international conference on Optical Fibre Sensors first appeared in 1983 in London then emerged into a series travelling from Europe to the Americas and into the Asia-Pacific region. The 20th in the series took place in Edinburgh at the end of 2009 and this special issue of Measurement Science and Technology presents extended versions of some of the papers that first appeared at the conference. The science and technology of fibre sensing have evolved significantly over the history of the conference, drawing on developments in optical

  16. Crack Growth Monitoring by Embedded Optical Fibre Bragg Grating Sensors: Fibre Reinforced Plastic Crack Growing Detection

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; Mikkelsen, Lars Pilgaard; McGugan, Malcolm

    2015-01-01

    This article presents a novel method to asses a crack growing/damage event in fibre reinforced plastic, or adhesive using Fibre Bragg Grating (FBG) sensors embedded in a host material. Different features of the crack mechanism that induce a change in the FBG response were identified. Double Canti...

  17. Multiplexed fibre optic sensors for monitoring resin infusion, flow, and cure in composite material processing

    Science.gov (United States)

    Chehura, Edmon; Jarzebinska, Renata; Da Costa, Elisabete F. R.; Skordos, Alexandros A.; James, Stephen W.; Partridge, Ivana K.; Tatam, Ralph P.

    2013-04-01

    The infusion, flow and cure of RTM6 resin in a carbon fibre reinforced composite preform have been monitored using a variety of multiplexed fibre optic sensors. Optical fibre Fresnel sensors and tilted fibre Bragg grating (TFBG) sensors were configured to monitor resin infusion/flow in-plane of the component. The results obtained from the different sensors were in good agreement with visual observations. The degree of cure was monitored by Fresnel sensors via a measurement of the refractive index of the resin which was converted to degree of cure using a calibration determined from Differential Scanning Calorimetry. Fibre Bragg grating sensors fabricated in highly linearly birefringent fibre were used to monitor the development of transverse strain during the cure process, revealing through-thickness material shrinkage of about 712 μɛ and residual strain of 223 μɛ. An alternative approach to infusion monitoring, based on an array of multiplexed tapered optical fibre sensors interrogated using optical frequency domain reflectometry, was also investigated in a separate carbon fibre preform that was infused with RTM6 resin.

  18. Blue light emitting diodes for optical stimulation of quartz in retrospective dosimetry and dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Duller, G.A.T.; Murray, A.S.

    1999-01-01

    (470 nm) gives order of magnitude greater rate of stimulation in quartz than that from conventional blue-green light filtered from a halogen lamp. A practical blue LED OSL configuration is described. From comparisons of OSL decay curves produced by green and blue light sources, and by examination......Recently developed blue light emitting diodes (LEDs) for the optical stimulation of quartz for use in routine optically stimulated luminescence (OSL) dating and retrospective dosimetry have been tested. For similar power densities, it was found that the higher energy light provided by the blue LEDs...... of the dependence of the blue LED OSL on preheat temperature, it is deduced that there is no evidence that the blue LEDs stimulate deep traps in a different manner from broadband filtered light. It is concluded that blue LEDs offer a practical alternative to existing stimulation sources. They have the significant...

  19. A Model of Magneto-mechano-optical Transfer in Fibre-optic Magnetic Sensors with Magnetostrictive Films

    Institute of Scientific and Technical Information of China (English)

    LIU Ji-yan; SI Yong-min

    2004-01-01

    Fibre-optic magnetic sensors with magnetostrictive films are used as all-fibre Mach-Zehnder interferometer to detect the optical phase shift, which is caused by the magnetostriction-induced strains transferred from the msgnetostrictive film to the fibre. A theoretical model based on the plane strain approximation and uniform axial strain is developed to determine the magneto-mechano-optical transfer relations in this kind of sensors. The expression for the model is presented as well as relation of the phase shift in the fibre to the magnetic and elastic properties of the magnetostrictive film coated on the fibre. And from the model, the thickness of the film has significant influence on the phase shift.

  20. Thermal Properties of Loose Tube Secondary Coated Optical Fibres Experimentally Discussed by a Relative Light Pulse Delay Technique

    Science.gov (United States)

    1983-11-17

    mechanical stability of fibre optic cables for example, shrinkage of the extruded operating at varying ambient conditions, plastic tubes at elevated...heating process. Controlling the Fibre Excess Length In the design of fibre optic cables -- with respect to temperature characteri- stics, it should be

  1. Synchrotron generated X-ray Excited Optical Luminescence (XEOL) from Quartz

    Science.gov (United States)

    King, Georgina; Finch, Adrian; Robinson, Ruth

    2010-05-01

    Quartz is the preferred mineral for optically stimulated luminescence (OSL) dating, due to its well constrained behaviour as a radiation dosimeter. However, despite the plethora of successful quartz OSL applications, no solution has been found to the problem that some quartz luminesce more brightly than others, which has limited the application of OSL in certain settings. This has been addressed through examination of the luminescence emission using a variety of excitation techniques and emission spectroscopy. X-ray Excited Optical Luminescence (XEOL) is luminescence excited by x-rays produced by a synchrotron. XEOL analyses were conducted upon a suite of quartz samples at Diamond, Great Britain, which had previously been analysed with Ionoluminescence (IL), at Sussex University. The samples were selected to include quartz of both poor and excellent OSL sensitivities. Therefore, two Scottish glacial outwash samples prepared at St Andrews, and a calibration quartz sample, prepared at the Risø National Laboratory in Denmark were analysed for these properties respectively. The XEOL emission spectra comprised three major emissions at 3.32, 3.81 and 4.05 eV, and one weaker emission at 1.94 eV in all samples. The calibration quartz sample had the most intense emission by an order of magnitude. Throughout increased exposure to x-rays, the intensity of the UV emission reduced, and an increase in the red (1.94 eV) emission was recorded. The derived XEOL spectra complement the IL spectra obtained previously. The IL spectra were dominated by only two broad emissions at 3.2-3.1 eV and 1.8-1.7 eV. However, throughout the IL experiments a dose dependent effect was also observed, whereby the UV emission was depleted to the benefit of the red with increasing exposure. Furthermore the gradient of the power law relationship between the UV and red emission change with dose is similar for both the IL and XEOL data: at -1.15 and -1.05 respectively for calibration quartz, when plotted

  2. Crack Growth Monitoring by Embedded Optical Fibre Bragg Grating Sensors: Fibre Reinforced Plastic Crack Growing Detection

    DEFF Research Database (Denmark)

    Pereira, Gilmar Ferreira; Mikkelsen, Lars Pilgaard; McGugan, Malcolm

    2015-01-01

    This article presents a novel method to asses a crack growing/damage event in fibre reinforced plastic, or adhesive using Fibre Bragg Grating (FBG) sensors embedded in a host material. Different features of the crack mechanism that induce a change in the FBG response were identified. Double...... Cantilever Beams specimens made with glass fibre glued with structural adhesive, were instrumented with an array of FBG sensors embedded in the material and tested using an experimental fracture procedure. A digital image correlation technique was used to determine the presence of the specific phenomena...

  3. Measurement of Rotating Blade Tip Clearance with Fibre-Optic Probe

    Energy Technology Data Exchange (ETDEWEB)

    Cao, S Z; Duan, F J; Zhang, Y G [State Key Laboratory of Measurement Technology and Instruments, Tianjin, University. Tianjin, 300072 (China)

    2006-10-15

    This paper described a tip clearance measuring system with fibre-optic probe. The system is based on a novel tip clearance sensor of optical fibre-bundle mounted on the casing, rotating speed synchronization sensor mounted on the rotating shaft, the tip clearance preamplification processing circuit followed by high speed data-acquisition unit. A novel tip clearance sensor of trifurcated optical fibre bundle was proposed and demonstrated. It is independent of material of measured surface but capacitive probe demands target conductive. Measurements can be taken under severe conditions such as ionization. Sensor circuitry and data acquisition circuit were successfully designed. With the help of Rotation synchronized sensor, all the blades can be detected in real-time. Because of fibre-optic sensor, the measuring system has commendably frequency response, which can work well in high rotating speed from 0-15000rpm.The measurement range of tip clearance is 0-3mm with 25um precision.

  4. Optical Fibre Beam Delivery of High Average Power NEODYMIUM:YAG Laser Radiation

    Science.gov (United States)

    Boechat, Alvaro A. P.

    Available from UMI in association with The British Library. This thesis presents a study of the waveguiding properties of large core (200-1000mum core diameter), relatively short length (5-50m) multimode optical fibres used for delivery of Nd:YAG laser radiation at a wavelength of 1.06mum. A major objective of the study was to provide design information for beam delivery systems used in high power materials processing application. Experimental and theoretical investigation of the optical losses produced by bending the fibre lead to a model which can be used to predict the magnitude of the bend loss as a function of launching conditions, bend geometry and fibre parameters. The study confirms the importance of using large numerical aperture, small core diameter fibres to minimise losses. It has been shown that the beam output near field profile from a fibre is a function of the launching conditions. Theoretical and experimental study of the effect for both step and graded index fibres is presented. Geometric optics and phase space theory was used to develop a model in which a relationship between input and output beam quality from a graded index fibre was established. The results showed that there is an optimum launching condition for which the beam quality may be preserved for fibres with quadratic index profiles. The effect of curvature induced mode coupling on beam quality has been studied experimentally, and compared with intrinsic mode coupling effects. The study was supported by the development of a simple theoretical mode coupling model. Finally, a new monitoring technique for beam delivery systems was developed, based on detection of power in the fibre cladding. Applications include determining laser -fibre coupling efficiency, fibre integrity monitoring, and providing real time process information.

  5. Nonlinear Pulse Shaping in Fibres for Pulse Generation and Optical Processing

    Directory of Open Access Journals (Sweden)

    Sonia Boscolo

    2012-01-01

    Full Text Available The development of new all-optical technologies for data processing and signal manipulation is a field of growing importance with a strong potential for numerous applications in diverse areas of modern science. Nonlinear phenomena occurring in optical fibres have many attractive features and great, but not yet fully explored, potential in signal processing. Here, we review recent progress on the use of fibre nonlinearities for the generation and shaping of optical pulses and on the applications of advanced pulse shapes in all-optical signal processing. Amongst other topics, we will discuss ultrahigh repetition rate pulse sources, the generation of parabolic shaped pulses in active and passive fibres, the generation of pulses with triangular temporal profiles, and coherent supercontinuum sources. The signal processing applications will span optical regeneration, linear distortion compensation, optical decision at the receiver in optical communication systems, spectral and temporal signal doubling, and frequency conversion.

  6. Spatial Kerr solitons in optical fibres of finite size cross section: beyond the Townes soliton

    Science.gov (United States)

    Drouart, F.; Renversez, G.; Nicolet, A.; Geuzaine, C.

    2008-12-01

    We propose a new and efficient numerical method to find spatial solitons in optical fibres with a nonlinear Kerr effect including microstructured ones. A nonlinear non-paraxial scalar model of the electric field in the fibre is used (nonlinear Helmholtz equation) and an iterative algorithm is proposed to obtain the nonlinear solutions using the finite element method. The field is supposed to be harmonic in time and along the direction of invariance of the fibre but inhomogeneous in the cross section. In our approach, we solve a nonlinear eigenvalue problem in which the propagation constant is the eigenvalue. Several examples dealing with step-index fibres and microstructured optical fibres with a finite size cross section are described. In each geometry, a single self-coherent nonlinear solution is obtained. This solution, which also depends on the size of the structure, is different from the Townes soliton—but converges towards it at small wavelengths.

  7. A beam monitor detector based on doped silica and optical fibres

    CERN Document Server

    Braccini, S; Giacoppo, F; Kreslo, I; Nesteruk, K P; Nirkko, M; Weber, M; Scampoli, P; Neff, M; Pilz, S; Romano, V

    2011-01-01

    A beam monitor detector based on doped silica and optical fibres has been designed, constructed and tested, mainly for accelerators used in medical applications. We conceived a general-purpose device, suitable either for low currents used in hadrontherapy or for high currents typical for radioisotope production, as well as for both pulsed and continuous beams. Scintillation light produced by Ce and Sb doped silica fibres moved across the beam is measured, giving information on its position, shape and intensity. The coupling of the doped fibre to an ordinary optical fibre allows the read-out of the signal far away from the radiation source. Mostly based on commercial components, the detector is easy to install and operate also in a high radiation environment due to the absence of any radiation sensitive electronics located near the fibre. The first successful beam tests triggered new developments toward the realization of a two-dimensional beam profiler and the miniaturization of the full device.

  8. Improving performance of optical fibre chaotic communication by dispersion compensation techniques

    Institute of Scientific and Technical Information of China (English)

    Zhang Jian-Zhong; Wang Yun-Cai; Wang An-Bang

    2008-01-01

    This paper numerically investigates the effects of dispersion on optical fibre chaotic communication,and proposes a dispersion compensation scheme to improve the performance of optical fibre chaotic communication system.The obtained results show that the transmitter-receiver synchronization progressively degrades and the signal-to-noise ratio of the recovered message deteriorates as the fibre length increases due to the dispersion accumulation.Two segments of 2.5-km dispersion-compensating fibres are symmetrically placed at both ends of a segment of 245-km nonzero dispersionshifted fibre with low dispersion in one compensation period.The numerical results show that the signal-to-noise ratio of the extracted 1 GHz sinusoidal message is improved from-2.92 dB to 15.38 dB by this dispemion compensation for the transmission distance of 500 km.

  9. A set-up to measure the optical attenuation length of scintillating fibres

    CERN Document Server

    Alfieri, C; Joram, C

    2015-01-01

    The optical attenuation length of a scintillating fibre characterizes the quality of light transport through the fibre. It relates directly to the quantity of detectable light at the readout end of the fibre. An optical bench has been constructed, which allows excitation of the fibre at various distances from the photodetector. Depending on the choice of the photodetector – Si-PIN photodiode or grating spectrometer – the attenuation length is measured as weighted average over the sensitivity of the photodetector or as a spectral distribution. A few examples illustrate its operation and performance. The set-up serves for fibre optimisation in the R&D phase and is expected to be used for systematic checks during the series production phase of the LHCb SciFi tracker project.

  10. Power transmission coefficients for multi-step index optical fibres.

    Science.gov (United States)

    Aldabaldetreku, Gotzon; Zubia, Joseba; Durana, Gaizka; Arrue, Jon

    2006-02-20

    The aim of the present paper is to provide a single analytical expression of the power transmission coefficient for leaky rays in multi-step index (MSI) fibres. This expression is valid for all tunnelling and refracting rays and allows us to evaluate numerically the power attenuation along an MSI fibre of an arbitrary number of layers. We validate our analysis by comparing the results obtained for limit cases of MSI fibres with those corresponding to step-index (SI) and graded-index (GI) fibres. We also make a similar comparison between this theoretical expression and the use of the WKB solutions of the scalar wave equation.

  11. Periodic refractive index modifications inscribed in polymer optical fibre by focussed IR femtosecond pulses

    DEFF Research Database (Denmark)

    Stecher, Matthias; Williams, Robert J.; Bang, Ole

    Focussed femtosecond laser pulses were used to inscribe a periodic array of modifications in the core of a polymer optical fibre. Structural and refractive-index modifications have been observed at different pulse energies using DIC microscopy.......Focussed femtosecond laser pulses were used to inscribe a periodic array of modifications in the core of a polymer optical fibre. Structural and refractive-index modifications have been observed at different pulse energies using DIC microscopy....

  12. Full Spectrum Diffused and Beamed Solar Energy Application Using Optical Fibre

    OpenAIRE

    Majumdar, M. R. Dutta; Das, Debasish

    2007-01-01

    Existing solar energy application systems use small fraction of full spectrum of solar energy. So attempts are made to show how full spectrum solar energy can be used for diffused and beamed form of incident solar energy. Luminescent Solar Concentrator (LSC) principle with optical fibre in diffused sun light and dielectric mirror separation technique with optical fibre in beamed form are discussed. Comparison of both the cases are done. Keywords: full spectrum, solar photonics, diffused solar...

  13. Full Spectrum Diffused and Beamed Solar Energy Application Using Optical Fibre

    OpenAIRE

    Majumdar, M. R. Dutta; Das, Debasish

    2007-01-01

    Existing solar energy application systems use small fraction of full spectrum of solar energy. So attempts are made to show how full spectrum solar energy can be used for diffused and beamed form of incident solar energy. Luminescent Solar Concentrator (LSC) principle with optical fibre in diffused sun light and dielectric mirror separation technique with optical fibre in beamed form are discussed. Comparison of both the cases are done. Keywords: full spectrum, solar photonics, diffused solar...

  14. Signal Processing for Fibre-optic Distributed Sensing Techniques Employing Brillouin Scattering

    Institute of Scientific and Technical Information of China (English)

    XIAO Shang-hui; LI Li

    2009-01-01

    As fibre optic distributed scattering sensing systems are providing innovative solutions for the monitoring of large structures, Brillouin-based distributed scattering sensing techniques represent a new physical approach for structures health monitoring, which seems extremely promising and is receiving most attentions. This paper comprehensively presents some methods of signal interrogation for fibre optic Brillouin-based distributed scattering sensing technology, especially establishes an accurate Pseudo-Voigt model of Brillouin gain spectrum and gives some results on spectrum analysis and data processing.

  15. Investigation of the in-solution relaxation of polymer optical fibre Bragg gratings

    DEFF Research Database (Denmark)

    Fasano, Andrea; Woyessa, Getinet; Janting, Jakob

    2016-01-01

    We investigate the response of PMMA microstructured polymer optical fibre Bragg gratings whenimmersed in methanol/water solutions. Overall we observe a permanent blue-shift in Bragg gratingwavelength after solvent evaporation. The main contribution in the resonance wavelength shift probably...... arisesfrom a permanent change in the size of the fibre, as already reported for high-temperature annealing ofpolymer optical fibres. As a consequence of the solution concentration dependence of the glass transitiontemperature of polymers, different methanol/water solutions lead to various degrees of frozen...

  16. A guiding light: spectroscopy on digital microfluidic devices using in-plane optical fibre waveguides.

    Science.gov (United States)

    Choi, Kihwan; Mudrik, Jared M; Wheeler, Aaron R

    2015-09-01

    We present a novel method for in-plane digital microfluidic spectroscopy. In this technique, a custom manifold (.stl file available online as ESM) aligns optical fibres with a digital microfluidic device, allowing optical measurements to be made in the plane of the device. Because of the greater width vs thickness of a droplet on-device, the in-plane alignment of this technique allows it to outperform the sensitivity of vertical absorbance measurements on digital microfluidic (DMF) devices by ∼14×. The new system also has greater calibration sensitivity for thymol blue measurements than the popular NanoDrop system by ∼2.5×. The improvements in absorbance sensitivity result from increased path length, as well as from additional effects likely caused by liquid lensing, in which the presence of a water droplet between optical fibres increases fibre-to-fibre transmission of light by ∼2× through refraction and internal reflection. For interrogation of dilute samples, stretching of droplets using digital microfluidic electrodes and adjustment of fibre-to-fibre gap width allows absorbance path length to be changed on-demand. We anticipate this new digital microfluidic optical fibre absorbance and fluorescence measurement system will be useful for a wide variety of analytical applications involving microvolume samples with digital microfluidics.

  17. Optical fibre luminescence sensor for real-time LDR brachytherapy dosimetry

    Science.gov (United States)

    Woulfe, P.; Sullivan, F. J.; O'Keeffe, S.

    2016-05-01

    An optical fibre sensor for monitoring low dose radiation is presented. The sensor is based on a scintillation material embedded within the optical fibre core, which emits visible light when exposed to low level ionising radiation. The incident level of ionising radiation can be determined by analysing the optical emission. An optical fibre sensor is presented, based on radioluminescence whereby radiation sensitive scintillation material, terbium doped gadolinium oxysulphide (Gd2O2S:Tb), is embedded in a cavity of 250μm of a 500μm plastic optical fibre. The sensor is designed for in-vivo monitoring of the radiation dose during radio-active seed implantation for brachytherapy, in prostate cancer treatment, providing oncologists with real-time information of the radiation dose to the target area and/or nearby critical structures. The radiation from the brachytherapy seeds causes emission of visible light from the scintillation material through the process of radioluminescence, which penetrates the fibre, propagating along the optical fibre for remote detection using a multi-pixel photon counter. The sensor demonstrates a high sensitivity to Iodine-125, the radioactive source most commonly used in brachytherapy for treating prostate cancer.

  18. Long Optical Delay Lines Enhanced by Ring Configuration in Optical Fibres

    Institute of Scientific and Technical Information of China (English)

    DONG Yong-Kang; LU Zhi-Wei; LI Qiang; GAO Wei

    2007-01-01

    A long optically controlled delay line enhanced by ring configuration is demonstrated by using the group-velocity control of signal pulses based on stimulated Brillouin scattering. In experiment, two optical fibre ring cavities are used: one is used as the Brillouin laser, providing single-mode Stokes wave as probe wave; the other is used as the Brillouin amplifier, working as slow light medium. We achieve a maximum time delay of 215ns using the ring Brillouin amplifier, five times larger than the input probe pulse width of 40ns. In the meantime, a considerable pulse broadening is observed, which agrees well with the theoretical prediction based on linear theory.

  19. Compaction in optical fibres and fibre Bragg gratings under nuclear reactor high neutron and gamma fluence

    Energy Technology Data Exchange (ETDEWEB)

    Remy, L.; Cheymol, G. [CEA, French Nuclear Energy Commission, Nuclear Energy Division, DPC/SEARS/LISL Bat 467 CEA Saclay 91191 Gif/Yvette Cedex (France); Gusarov, A. [SCK.CEN - Belgian Nuclear Research center, Boeretang 200 2400 Mol (Belgium); Morana, A.; Marin, E.; Girard, S. [Universite de Saint-Etienne, Laboratoire Hubert Curien, UMR CNRS5516, 18, rue du Pr. Lauras, F-42000 Saint-Etienne (France)

    2015-07-01

    In the framework of the development by CEA and SCK.CEN of a Fabry Perot Sensor (FPS) able to measure dimensional changes in Material Testing Reactor (MTR), the first goal of the SAKE 1 (Smirnof extention - Additional Key-tests on Elongation of glass fibres) irradiation was to measure the linear compaction of single mode fibres under high fast neutron fluence. Indeed, the compaction of the fibre which forms one side of the Fabry Perot cavity, may in particular cause a noticeable measurement error. An accurate quantification of this effect is then required to predict the radiation-induced drift and optimize the sensor design. To achieve this, an innovative approach was used. Approximately seventy uncoated fibre tips (length: 30 to 50 mm) have been prepared from several different fibre samples and were installed in the SCK.CEN BR2 reactor (Mol Belgium). After 22 days of irradiation a total fast (E > 1 MeV) fluence of 3 to 5x10{sup 19} n{sub fast}/cm{sup 2}, depending on the sample location, was accumulated. The temperature during irradiation was 291 deg. C, which is not far from the condition of the intended FPS use. A precise measurement of each fibre tip length was made before the irradiation and compared to the post irradiation measurement highlighting a decrease of the fibres' length corresponding to about 0.25% of linear compaction. The amplitude of the changes is independent of the capsule, which could mean that the compaction effect saturates even at the lowest considered fluence. In the prospect of performing distributed temperature measurement in MTR, several fibre Bragg gratings written using a femtosecond laser have been also irradiated. All the gratings were written in radiation hardened fibres, and underwent an additional treatment with a procedure enhancing their resistance to ionizing radiations. A special mounting made it possible to test the reflection and the transmission of the gratings on fibre samples cut down to 30 to 50 mm. The comparison

  20. Coupling light into optical fibres near the diffraction limit

    CERN Document Server

    Horton, A J; Horton, Anthony J.; Bland-Hawthorn, Joss

    2006-01-01

    The burgeoning field of astrophotonics explores the interface between astronomy and photonics. Important applications include photonic OH suppression at near-infrared wavelengths, and integrated photonic spectroscopy. These new photonic mechanisms are not well matched to conventional multi-mode fibres and are best fed with single or few-mode fibres. We envisage the largest gains in astrophotonics will come from instruments that operate with single or few-mode fibres in the diffraction limited or near diffraction limited regimes. While astronomical instruments have largely solved the problem of coupling light into multi-mode fibres this is largely unexplored territory for few-mode and single-mode fibres. Here we describe a project to explore this topic in detail, and present initial results on coupling light into single and few-mode fibres at the diffraction limit. We find that fibres with as few as ~5 guided modes have qualitatively different behaviour to single-mode fibres and share a number of the beneficia...

  1. Simple Room Temperature Method for Polymer Optical Fibre Cleaving

    DEFF Research Database (Denmark)

    Saez-Rodriguez, David; Nielsen, Kristian; Bang, Ole

    2015-01-01

    . In this paper, we make use of the temperature-time equivalence in polymers to replace the use of heating by an increase of the cleaving time and use a sawing motion to reduce fibre end face damage. In this way, the polymer fibre can be cleaved at room temperature in seconds with the resulting end face being...

  2. Heuristic approach to the passive optical network with fibre duct ...

    African Journals Online (AJOL)

    This paper uses concepts from network flow optimisation to incorporate fibre duct shar- .... Steiner tree T rooted in c so as to minimise the overall deployment cost .... sharing exist at road junctions where fibres can be routed together on one ...

  3. Fibre Optic System for Monitoring Rotational Seismic Phenomena

    Directory of Open Access Journals (Sweden)

    Anna Kurzych

    2014-03-01

    Full Text Available We outline the development and the application in a field test of the Autonomous Fibre-Optic Rotational Seismograph (AFORS, which utilizes the Sagnac effect for a direct measurement of the seismic-origin rotations of the ground. The main advantage of AFORS is its complete insensitivity to linear motions, as well as a direct measurement of rotational components emitted during seismic events. The presented system contains a special autonomous signal processing unit which optimizes its operation for the measurement of rotation motions, whereas the applied telemetric system based on the Internet allows for an AFORS remote control. The laboratory investigation of such two devices indicated that they keep an accuracy of no less than 5.1 × 10−9 to 5.5 × 10−8 rad/s in the detection frequency band from 0.83~106.15 Hz and protect linear changes of sensitivity in the above bandpass. Some experimental results of an AFORS-1 application for a continuous monitoring of the rotational events in the Książ (Poland seismological observatory are also presented.

  4. A fibre-optic oxygen sensor for monitoring human breathing.

    Science.gov (United States)

    Chen, Rongsheng; Formenti, Federico; Obeid, Andy; Hahn, Clive E W; Farmery, Andrew D

    2013-09-01

    The development and construction of a tapered-tip fibre-optic fluorescence based oxygen sensor is described. The sensor is suitable for fast and real-time monitoring of human breathing. The sensitivity and response time of the oxygen sensor were evaluated in vitro with a gas pressure chamber system, where oxygen partial pressure was rapidly changed between 5 and 15 kPa, and then in vivo in five healthy adult participants who synchronized their breathing to a metronome set at 10, 20, 30, 40, 50, and 60 breaths min(-1). A Datex Ultima medical gas analyser was used to monitor breathing rate as a comparator. The sensor's response time in vitro was less than 150 ms, which allows accurate continuous measurement of inspired and expired oxygen pressure. Measurements of breathing rate by means of our oxygen sensor and of the Datex Ultima were in strong agreement. The results demonstrate that the device can reliably resolve breathing rates up to 60 breaths min(-1), and that it is a suitable cost-effective alternative for monitoring breathing rates and end-tidal oxygen partial pressure in the clinical setting. The rapid response time of the sensor may allow its use for monitoring rapid breathing rates as occur in children and the newborn.

  5. Fibre optic system for monitoring rotational seismic phenomena.

    Science.gov (United States)

    Kurzych, Anna; Jaroszewicz, Leszek R; Krajewski, Zbigniew; Teisseyre, Krzysztof P; Kowalski, Jerzy K

    2014-03-19

    We outline the development and the application in a field test of the Autonomous Fibre-Optic Rotational Seismograph (AFORS), which utilizes the Sagnac effect for a direct measurement of the seismic-origin rotations of the ground. The main advantage of AFORS is its complete insensitivity to linear motions, as well as a direct measurement of rotational components emitted during seismic events. The presented system contains a special autonomous signal processing unit which optimizes its operation for the measurement of rotation motions, whereas the applied telemetric system based on the Internet allows for an AFORS remote control. The laboratory investigation of such two devices indicated that they keep an accuracy of no less than 5.1 × 10(-9) to 5.5 × 10(-8) rad/s in the detection frequency band from 0.83~106.15 Hz and protect linear changes of sensitivity in the above bandpass. Some experimental results of an AFORS-1 application for a continuous monitoring of the rotational events in the Książ (Poland) seismological observatory are also presented.

  6. Optically stimulated phosphorescence in quartz over the millisecond to second time scale: insights into the role of shallow traps in delaying luminescent recombination

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Jain, Mayank

    2010-01-01

    Time-resolved optically stimulated luminescence (TR-OSL) curves from quartz are usually measured over a few hundred microseconds because this time range best illustrates the main component in quartz which lies in the range 30–45 µs. In this study we present the decay form of quartz TR-OSL and opt......Time-resolved optically stimulated luminescence (TR-OSL) curves from quartz are usually measured over a few hundred microseconds because this time range best illustrates the main component in quartz which lies in the range 30–45 µs. In this study we present the decay form of quartz TR...

  7. Study of a fibre optics current sensor for the measurement of plasma current in ITER

    Science.gov (United States)

    Wuilpart, Marc; Vanus, Benoit; Andrasan, Alina; Gusarov, Andrei; Moreau, Philippe; Mégret, Patrice

    2016-05-01

    In this article, we study the feasibility of using a fibre-optics current sensor (FOCS) for the measurement of plasma current in the future fusion reactor ITER. The sensor is based on a classical FOCS interrogator involving the measurement of the state of polarization rotation undergone by the light in presence of a magnetic field (Faraday effect) in an optical fibre surrounding the current and terminated by a Faraday mirror. We considered a uniformly spun optical fibre as the sensing element and we used the Stokes formalism to simulate the sensor. The objective of the simulations is to quantify the ratio LB/SP (beat length over the spun period of the spun fibre) enabling a measurement error in agreement with the ITER specifications. The simulator takes into account the temperature variations undergone by the measurement system under ITER operation. The simulation work showed that a LB/SP ratio of 19.2 is adequate.

  8. A composite fibre optic catheter for monitoring peristaltic transit of an intra-luminal bead.

    Science.gov (United States)

    Arkwright, John W; Underhill, Ian D; Dodds, Kelsi N; Brookes, Simon J H; Costa, Marcello; Spencer, Nick J; Dinning, Phil G

    2016-03-01

    A fibre optic motion sensor has been developed for monitoring the proximity and direction of motion of a ferrous bead travelling axial to the sensor. By integrating an array of these sensors into our previously developed fibre optic manometry catheters we demonstrate simultaneous detection of peristaltic muscular activity and the associated motion of ferrous beads through a colonic lumen. This allows the motion of solid content to be temporally and spatially related to pressure variations generated by peristaltic contractions without resorting to videoflouroscopy to track the motion of a radio opaque bolus. The composite catheter has been tested in an in-vitro animal preparation consisting of excised sections of rabbit colon. Cut-away image of the fibre optic motion sensor showing the location of the fibre Bragg gratings and the rare earth magnet.

  9. Measurement of sound field in cavitating media by an optical fibre-tip hydrophone.

    Science.gov (United States)

    Koch, Christian; Jenderka, Klaus-Vitold

    2008-04-01

    A fibre-optic technique was applied to measure the sound field in an ultrasonic cleaning vessel under practical conditions. A metal-coated fibre-tip is used as a sensor and a heterodyne interferometer detects the change in the optical path resulting from the movement of the fibre-tip in the sound field. Spectrally resolved sound field parameters such as the fundamental, the subharmonic or cavitation noise are extracted from the measurements and compared with results obtained by a piezo-electric hydrophone. It was found that the fibre sensor provides a signal related to the velocity in the sound field, but the information about cavitation-related parameters is similar to the information for pressure sensing techniques. The fibre-optic sensors have a uniquely high spatial resolution and the sound detection process is strongly influenced by single cavitation events close to the small fibre-tip. This paper shows that fibre-tip sensors are an alternative to common hydrophone techniques. They can open up new possibilities for measurement problems for which so far no solution exists, in particular when a high spatial resolution is required or when the measurement site is small.

  10. Investigation of the limits of a fibre optic sensor system for measurement of temperature distribution

    DEFF Research Database (Denmark)

    Brehm, Robert; Johnson, Frank

    2006-01-01

    The aim of this project is to develop an innovative temperature sensor system which is able to measure the temperature distribution along a fibre optical cable. This technique for temperature measurement is based on Optical Time Domain Reflectometry (OTDR). ©2006 IEEE.......The aim of this project is to develop an innovative temperature sensor system which is able to measure the temperature distribution along a fibre optical cable. This technique for temperature measurement is based on Optical Time Domain Reflectometry (OTDR). ©2006 IEEE....

  11. Quantum logic operations on two distant atoms trapped in two optical-fibre-connected cavities

    Institute of Scientific and Technical Information of China (English)

    Zhang Ying-Qiao; Zhang Shou; Yeon Kyu-Hwang; Yu Seong-Cho

    2011-01-01

    Based on the coupling of two distant three-level atoms in two separate optical cavities connected with two optical fibres,schemes on the generation of several two-qubit logic gates are discussed under the conditions of △ =δ -2v cos πk/2 (》) g/2 and (v~ g).Discussion and analysis of the fidelity,gate time and experimental setups show that our schemes are feasible with current optical cavity,atomic trap and optical fibre techniques.Moreover,the atom-cavityfibre coupling can be used to generate an N-qubit nonlocal entanglement and transfer quantum information among N distant atoms by arranging N atom-cavity assemblages in a line and connecting each two adjacent cavities with two optical fibres.

  12. Quartz optical filter for wavelength selection of frequency-doubled laser based on optical rotatory dispersion effect

    Institute of Scientific and Technical Information of China (English)

    Shan Zhang; Fuquan Wu; Wendi Wu; Haifeng Wang

    2007-01-01

    Based on the optical rotatory dispersion effect, an optical filter for selecting the second harmonic of a frequency-doubled laser is constructed from quartz in combination with polarizers. The operating principle is analyzed by matrix formulation, and the result indicates that the second harmonic of a frequency-doubled laser will be obtained when the rotation angle has a difference of (2n + 1)π/2 (n = 0, 1, 2, 3,… ) between the two polarizations of the second-harmonic laser and the fundamental laser. The spectrum of the output laser is taken by the AQ-6315A spectrometer, and the experimental results are in good agreement with the theoretical results.

  13. Quantum storage of entangled telecom-wavelength photons in an erbium-doped optical fibre

    Science.gov (United States)

    Saglamyurek, Erhan; Jin, Jeongwan; Verma, Varun B.; Shaw, Matthew D.; Marsili, Francesco; Nam, Sae Woo; Oblak, Daniel; Tittel, Wolfgang

    2015-02-01

    The realization of a future quantum Internet requires the processing and storage of quantum information at local nodes and interconnecting distant nodes using free-space and fibre-optic links. Quantum memories for light are key elements of such quantum networks. However, to date, neither an atomic quantum memory for non-classical states of light operating at a wavelength compatible with standard telecom fibre infrastructure, nor a fibre-based implementation of a quantum memory, has been reported. Here, we demonstrate the storage and faithful recall of the state of a 1,532 nm wavelength photon entangled with a 795 nm photon, in an ensemble of cryogenically cooled erbium ions doped into a 20-m-long silica fibre, using a photon-echo quantum memory protocol. Despite its currently limited efficiency and storage time, our broadband light-matter interface brings fibre-based quantum networks one step closer to reality.

  14. Modelling the thermal quenching mechanism in quartz based on time-resolved optically stimulated luminescence

    DEFF Research Database (Denmark)

    Pagonis, V.; Ankjærgaard, Christina; Murray, Andrew

    2010-01-01

    . As the temperature of the sample is increased, more electrons are removed from the excited state via the non-radiative pathway. This reduction in the number of available electrons leads to both a decrease of the intensity of the luminescence signal and to a simultaneous decrease of the luminescence lifetime. Several...... simulations are carried out of time-resolved optically stimulated luminescence (TR-OSL) experiments, in which the temperature dependence of luminescence lifetimes in quartz is studied as a function of the stimulation temperature. Good quantitative agreement is found between the simulation results and new...

  15. Zero Dispersion Optical Fibres for High Data Rate Systems

    Directory of Open Access Journals (Sweden)

    V. V. Rampal

    1981-07-01

    Full Text Available The different dispersion parameters that contribute to the pulse spreading in a single mode fibre are discussed with particular reference to the possibility of reducing the total dispersion to zero and increasing the bandwidth and repeater spacing.

  16. Optically stimulated luminescence techniques in retrospective dosimetry using single grains of quartz extracted from unheated materials

    Energy Technology Data Exchange (ETDEWEB)

    Joerkov Thomsen, Kristina

    2004-02-01

    This work investigates the possibility of applying optically stimulated luminescence (OSL) in retrospective dose determinations using unheated materials. It focuses on identifying materials suitable for use in assessment of doses absorbed as a consequence of radiation accidents (i.e. accident dosimetry). Special attention has been paid to quartz extracted from unheated building materials such as concrete and mortar. The single-aliquot regeneration-dose (SAR) protocol has been used to determine absorbed doses in small aliquots as well as single grains of quartz. It is shown that OSL measurements of single grains of quartz extracted from poorly-bleached building materials can provide useful information on radiation accident doses, even when the luminescence sensitivity is low. Sources of variance in well-bleached single grain dose distributions have been investigated in detail and it is concluded that the observed variability in the data is consistent with the sum (in quadrature) of a component, which depends on the number of photons detected from each grain, and a fixed component independent of light level. Dose depth profiles through laboratory irradiated concrete bricks have successfully been measured and minimum detection limits of less than 100 mGy are derived. Measurements of thermal transfer in single grains of poorly-bleached quartz show that thermal transfer is variable on a grain-to-grain basis and that it can be a source of variance in single-grain dose distributions. Furthermore, the potential of using common household and workplace chemicals, such as table salt, washing powder and water softener, in retrospective dosimetry has been investigated. It is concluded that such materials should be considered as retrospective dosimeters in the event of a radiation accident. (au)

  17. Suppression of phase-induced intensity noise in fibre optic delay line signal processors using an optical phase modulation technique.

    Science.gov (United States)

    Chan, Erwin H W

    2010-10-11

    A technique that can suppress the dominant phase-induced intensity noise in fibre optic delay line signal processors is presented. It is based on phase modulation of the optical carrier to distribute the phase noise at the information band into a high frequency band which can be filtered out. This technique is suitable for suppressing the phase noise in various delay line structures and for integrating in the conventional fibre optic links. It can also suppress the coherent interference effect at the same time. A model for predicting the amount of phase noise reduction in various delay line structures using the optical phase modulation technique is presented for the first time and is experimentally verified. Experimental results demonstrate the technique can achieve a large phase noise reduction in various fibre optic delay line signal processors.

  18. Thermal characterization of Bragg gratings in polarization-maintaining optical fibres: analysis of birefringence and regeneration

    Science.gov (United States)

    Abe, I.; de Oliveira, V.; Fiorin, R.; Kalinowski, H. J.

    2017-04-01

    This paper presents an analysis of birefringence and regeneration of fibre Bragg gratings (FBGs) in two types of polarization-maintaining (PM) optical fibres, bow tie and internal elliptical cladding (IEC), with different diameters. The thermal regeneration of FBGs in PM fibres with different degrees of saturation (weakly, slightly, and strongly saturated) is presented and the influence of the gratings’ saturation degree on the birefringence of PM fibres is shown. The birefringence values obtained for IEC fibres with 80 µm of diameter were for a strongly saturated seed grating of 5.3  ×  10-4 and 6.2  ×  10-4 refractive index units after the regeneration. The evolution of the fibre birefringence as a function of the temperature is presented and the results show hysteresis and nonlinear dependence of the birefringence on temperature. The thermal stability of regenerated gratings in PM fibres is demonstrated, and a sensitivity coefficient value of 0.0035 dBm min-1 at 900 °C was obtained. The results obtained show the feasibility of optimization of fibre birefringence; this could allow such fibers to be used as temperature sensors and even improve the birefringence after the grating regeneration.

  19. Integration of conductive reduced graphene oxide into microstructured optical fibres for optoelectronics applications.

    Science.gov (United States)

    Ruan, Yinlan; Ding, Liyun; Duan, Jingjing; Ebendorff-Heidepriem, Heike; Monro, Tanya M

    2016-02-22

    Integration of conductive materials into optical fibres can largely expand functions of fibre devices including surface plasmon resonator/metamaterial, modulators/detectors, or biosensors. Some early attempts have been made to incorporate metals such as tin into fibres during the fibre drawing process. Due to the restricted range of materials that have compatible melting temperatures with that of silica glass, the methods to incorporate metals along the length of the fibres are very challenging. Moreover, metals are nontransparent with strong light absorption, which causes high fibre loss. This article demonstrates a novel but simple method for creating transparent conductive reduced graphene oxide film onto microstructured silica fibres for potential optoelectronic applications. The strongly confined evanescent field of the suspended core fibres with only 2 μW average power was creatively used to transform graphene oxide into reduced graphene oxide with negligible additional loss. Existence of reduced graphene oxide was confirmed by their characteristic Raman signals, shifting of their fluorescence peaks as well as largely decreased resistance of the bulk GO film after laser beam exposure.

  20. Nonlinear fibre-optic devices pumped by semiconductor disk lasers

    Energy Technology Data Exchange (ETDEWEB)

    Chamorovskiy, A Yu; Okhotnikov, Oleg G [Optoelectronics Research Center, Tampere University of Technology, Tampere (Finland)

    2012-11-30

    Semiconductor disk lasers offer a unique combination of characteristics that are particularly attractive for pumping Raman lasers and amplifiers. The advantages of disk lasers include a low relative noise intensity (-150 dB Hz{sup -1}), scalable (on the order of several watts) output power, and nearly diffraction-limited beam quality resulting in a high ({approx}70 % - 90 %) coupling efficiency into a single-mode fibre. Using this technology, low-noise fibre Raman amplifiers operating at 1.3 {mu}m in co-propagation configuration are developed. A hybrid Raman-bismuth doped fibre amplifier is proposed to further increase the pump conversion efficiency. The possibility of fabricating mode-locked picosecond fibre lasers operating under both normal and anomalous dispersion is shown experimentally. We demonstrate the operation of 1.38-{mu}m and 1.6-{mu}m passively mode-locked Raman fibre lasers pumped by 1.29-{mu}m and 1.48-{mu}m semiconductor disk lasers and producing 1.97- and 2.7-ps pulses, respectively. Using a picosecond semiconductor disk laser amplified with an ytterbium-erbium fibre amplifier, the supercontinuum generation spanning from 1.35 {mu}m to 2 {mu}m is achieved with an average power of 3.5 W. (invited paper)

  1. Palladium coated ball lens for optical fibre refractometry based hydrogen sensing

    Science.gov (United States)

    Chowdhury, Sahar A.; Correia, Ricardo; Francis, Daniel; Brooks, Simon J.; Jones, Ben J. S.; Thompson, Alexander W. J.; Hodgkinson, Jane; Tatam, Ralph P.

    2014-05-01

    An optical fibre refractometer using a ball lens as a sensor head has been developed and characterised. Light from a superluminescent diode is directed to an optical fibre sensor head and the intensity of the returned beam gives a measure of the refractive index of the medium at the ball lens fibre tip. A second beam is used to reference the intensity measurements. The system is capable of detecting changes in refractive index with a resolution of 0.003 RIU. The ball lenses have been coated with an 80nm thick layer of palladium and the potential use of this system as a micromirror hydrogen sensor is demonstrated. This technique offers a simple sensor head arrangement, with a large signal sampling area compared with that of a bare fibre.

  2. Fibres reinforced dentures investigated with en-face optical coherence tomography

    Science.gov (United States)

    Negrutiu, Meda L.; Sinescu, Cosmin; Hughes, Michael; Bradu, Adrian; Goguta, Luciana; Rominu, Mihai; Negru, Radu; Podoleanu, Adrian Gh.

    2008-04-01

    The complete dentures are currently made using different technologies. In order to avoid deficiencies of the prostheses made using the classical technique, several alternative procedures have been devised. In order to enhance the mechanical strength, complete denture bases are reinforced with fibres. Their material and structure vary wildly, which makes the investigation difficult. In this study, optical coherence tomography (OCT) is evaluated as a possible non-invasive technique to assess the biomechanical behaviour of the reinforcing fibres. OCT images demonstrate structural defects between fibres and the acrylic material in all dentures bases investigated. We conclude that OCT can successfully be used as a noninvasive analysis method.

  3. Spectroscopic signature of phosphate crystallization in Erbium-doped optical fibre preforms

    CERN Document Server

    Peretti, Romain; Jacquier, Bernard; Blanc, Wilfried; Dussardier, Bernard; 10.1016/j.optmat.2011.01.005

    2011-01-01

    In rare-earth-doped silica optical fibres, the homogeneous distribution of amplifying ions and part of their spectroscopic properties are usually improved by adding selected elements, such as phosphorus or aluminum, as structural modifier. In erbium ion (Er3+) doped fibres, phosphorus preferentially coordinates to Er3+ ions to form regular cages around it. However, the crystalline structures described in literature never gave particular spectroscopic signature. In this article, we report emission and excitation spectra of Er3+ in a transparent phosphorus-doped silica fibre preform. The observed line features observed at room and low temperature are attributed to ErPO4 crystallites.

  4. Fabry-Perot micro-structured polymer optical fibre sensors for opto-acoustic endoscopy

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet;

    2015-01-01

    Opto-Acoustic Endoscopy (OAE) requires sensors with a high sensitivity and small physical dimensions in order to facilitate integration into an endoscope of less than 1mm in diameter. We present fibre Bragg grating (FBG) and Fabry- Perot intrinsic fibre sensors for ultrasound detection. We presen...... and a simplification of the detection regime for an optimal interferometric OAE configuration. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  5. Fibre-optic photochemical stroke: generating and measuring photochemical changes inside the brain

    Science.gov (United States)

    Tsiminis, G.; Klarić, T. S.; Schartner, E. P.; Warren-Smith, S. C.; Lewis, M. D.; Koblar, S. A.; Monro, T. M.

    2014-05-01

    We report here on the development of a method to induce a stroke in a specific location within a mouse brain through the use of an optical fibre. By capturing the emitted fluorescence signal generated using the same fibre it is then possible to monitor photochemical changes within the brain in real-time, potentially reducing the requirement for post-operative histology to determine if a stroke has successfully been induced within the animal.

  6. Comparison of Numerical Modelling of Degradation Mechanisms in Single Mode Optical Fibre Using MATLAB and VPIphotonics

    Directory of Open Access Journals (Sweden)

    Jana Sajgalikova

    2015-01-01

    Full Text Available Mathematical models for description of physical phenomena often use the statistical description of the individual phenomena and solve those using suitable methods. If we want to develop numerical model of optical communication system based on transmission through single mode optical fibres, we need to consider whole series of phenomena that affect various parts of the system. In the single-mode optical fibre we often encounter influence of chromatic dispersion and nonlinear Kerr effects. By observing various different degradation mechanisms, every numerical model should have its own limits, which fulfil more detailed specification. It is inevitable to consider them in evaluation. In this paper, we focus on numerical modelling of degradation mechanisms in single-mode optical fibre. Numerical solution of non-linear Schroedinger equation is performed by finite difference method applied in MATLAB environment and split-step Fourier method, which is implemented by VPIphotonics software.

  7. Reliability of optical fibres and components final report of COST 246

    CERN Document Server

    Griffioen, Willem; Gadonna, Michel; Limberger, Hans; Heens, Bernard; Knuuttila, Hanna; Kurkjian, Charles; Mirza, Shehzad; Opacic, Aleksandar; Regio, Paola; Semjonov, Sergei

    1999-01-01

    Reliability of Optical Fibres and Components reports the findings of COST 246 (1993-1998) - European research initiative in the field of optical telecommunications. Experts in the materials and reliability field of optical fibres and components have contributed to this unique study programme. The results, conclusions and achievements of their work have been obtained through joint experimentation and discussion with representatives from manufacturing and research groups. Topics covered include: Lifetime estimation; Failure mechanisms; Ageing test methods; Field data and service environments for components. For the first time the reader can explore the reliability of products and examine the results and conclusions in published form. This comprehensive volume is intended to provide a deeper understanding of the reliability of optical fibres and components. The book will be extremely useful to all scientists and practitioners involved in the industry.

  8. Improved fibre optic acoustic sensors for partial discharge in elastomeric insulations

    Science.gov (United States)

    Rohwetter, Philipp; Lothongkam, Chaiyaporn; Habel, Wolfgang; Heidmann, Gerd; Pepper, Daniel

    2014-05-01

    Partial discharge in elastomeric high voltage insulations is a major reason for device failure. The special challenges of the high voltage environment limit the use of conventional acoustic emission sensors. Fibre-optic sensors can cope with these challenges thanks to their optical sensing principle and the use of all-dielectric materials. In this contribution, improvements to a previously introduced design of ultrasonic fibre-optic acoustic partial discharge sensors for elastomeric insulations are presented. The improved performance of fibre-optic acoustic sensors in detecting AC partial discharge is demonstrated. Furthermore, their ability to detect low-level damage processes in elastomeric insulation under DC dielectric stress is shown to outperform the highly sensitive electrical detection method.

  9. Inverse four-wave-mixing and self-parametric amplification effect in optical fibre.

    Science.gov (United States)

    Turitsyn, Sergei K; Bednyakova, Anastasia E; Fedoruk, Mikhail P; Papernyi, Serguei B; Clements, Wallace R L

    2015-09-01

    An important group of nonlinear processes in optical fibre involves the mixing of four waves due to the intensity dependence of the refractive index. It is customary to distinguish between nonlinear effects that require external/pumping waves (cross-phase modulation and parametric processes such as four-wave mixing) and self-action of the propagating optical field (self-phase modulation and modulation instability). Here, we present a new nonlinear self-action effect, self-parametric amplification (SPA), which manifests itself as optical spectrum narrowing in normal dispersion fibre, leading to very stable propagation with a distinctive spectral distribution. The narrowing results from an inverse four-wave mixing, resembling an effective parametric amplification of the central part of the spectrum by energy transfer from the spectral tails. SPA and the observed stable nonlinear spectral propagation with random temporal waveform can find applications in optical communications and high power fibre lasers with nonlinear intra-cavity dynamics.

  10. Enhanced all-optical modulation in a graphene-coated fibre with low insertion loss

    Science.gov (United States)

    Zhang, Haojie; Healy, Noel; Shen, Li; Huang, Chung Che; Hewak, Daniel W.; Peacock, Anna C.

    2016-03-01

    Graphene is a highly versatile two-dimensional material platform that offers exceptional optical and electrical properties. Of these, its dynamic conductivity and low effective carrier mass are of particular interest for optoelectronic applications as they underpin the material’s broadband nonlinear optical absorption and ultra-fast carrier mobility, respectively. In this paper, we utilize these phenomena to demonstrate a high-speed, in-fibre optical modulator developed on a side-polished optical fibre platform. An especially low insertion loss (polyvinyl butyral layer, which has the added advantage of acting as a barrier to the surrounding environment. Using this innovative approach, we have fabricated a robust and stable all-fibre device with an extinction ratio as high as 9 dB and operation bandwidth of 0.5 THz. These results represent a key step towards the integration of low-dimensional materials within standard telecoms networks.

  11. EDITORIAL: The 19th International Conference on Optical Fibre Sensors, OFS-19 The 19th International Conference on Optical Fibre Sensors, OFS-19

    Science.gov (United States)

    Sampson, David D.; Jones, Julian D. C.; Tatam, Ralph P.

    2009-03-01

    OFS-19 was held in April 2008 in Perth, Australia, with Professor David Sampson (University of Western Australia) as General Chair assisted by Technical Programme Co-Chairs Professor Stephen Collins (Victoria University, Australia), Professor Kyunghwan Oh (Yonsei University, Korea) and Dr Ryozo Yamauchi (Fujikura Ltd, Japan). 'OFS-19' has once again affirmed the OFS series as the leading international conference for the optical fibre sensor community. Since its inception, in London in 1983, and under the leadership of an international steering committee independent of any learned society or professional institution, it has been held approximately every eighteen months. The venue nominally rotates from Europe, to the Americas, and thence to Asia and the Pacific. OFS-19 demonstrated the continuing vigour of the community, with some 240 papers presented, plus 8 tutorials; submissions and attendance were from 29 countries, with a little over half coming from the Asia-Pacific Region. In recent years, it has become a tradition to publish a post-conference special issue in Measurement Science and Technology, and these special issues offer a representative sample of the current status of the field. In the 25 years since OFS began, many of the early ideas and laboratory-based proof-of-principle experiments have successfully evolved into highly developed instrumentation systems and commercial products. One of the greatest success stories has been the optical fibre Bragg grating. Its exquisite intrinsic sensitivity to temperature and strain has led to an expanding niche in structural monitoring, especially in civil engineering. It has formed the 'beach-head' for penetration of optical fibre sensors into the oil and gas industry, initially in the harsh environment of down-hole monitoring. Latterly, it has paved the way for new applications of one of the earliest fibre optic sensors, the fibre hydrophone, which is now making its mark in sub-sea seismic surveying. Additionally

  12. Towards a new generation of fibre optic chemical sensors based on spider silk threads

    Science.gov (United States)

    Hey Tow, Kenny; Chow, Desmond M.; Vollrath, Fritz; Dicaire, Isabelle; Gheysens, Tom; Thévenaz, Luc

    2017-04-01

    A spider uses up to seven different types of silk, all having specific functions, to build its web. For scientists, native silk - directly extracted from spiders - is a tough, biodegradable and biocompatible thread used mainly for tissue engineering and textile applications. Blessed with outstanding optical properties, this protein strand can also be used as an optical fibre and is, moreover, intrinsically sensitive to chemical compounds. In this communication, a pioneering proof-of-concept experiment using spider silk, in its pristine condition, as a new type of fibre-optic relative humidity sensor will be demonstrated and its potential for future applications discussed.

  13. Shape memory polymeric composites sensing by optic fibre Bragg gratings: A very first approach

    Science.gov (United States)

    Quadrini, Fabrizio; Santo, Loredana; Ciminello, Monica; Concilio, Antonio; Volponi, Ruggero; Spena, Paola

    2016-05-01

    Shape memory polymer composites (SMPCs) have the potential for many applications in aerospace, spanning from self-repairing of structures to self-deploying of antennas, solar sails, or functional devices (e.g. for grabbing small space debris). In all these cases, it may be essential to have information about their configuration at different stages of shape recovery. In this study, the strain history of a prepreg carbon fibre system, cured with a shape memory polymer (SMP) interlayer, is monitored through a Fibre Bragg Grating (FBG), a fibre optic sensor device. SMPC has been manufactured by using traditional technologies for aerospace. After manufacturing cylindrical shape samples, an external fibre optic system is added to the composite structure; this system is especially suited for high temperatures which are necessary for SMP recovery and composite softening. Sensor functionality is checked before and after each strain history path. Optic fibre arrangement is optimized to avoid unwanted breakings whereas strains are limited by fibre collapsing, i.e. within nominal 2% of deformation. Dynamic information about shape recovery gives fundamental insights about strain evolution during time as well as its spatial distribution.

  14. Effect of soil temperature on one-way optical frequency transfer through dense-wavelength-division-multiplexing fibre links

    CERN Document Server

    Pinkert, T J; Jansen, G S M; Dijck, E A; Groeneveld, B G H M; Smets, R; Bosveld, F C; Ubachs, W; Jungmann, K; Eikema, K S E; Koelemeij, J C J

    2014-01-01

    Results of optical frequency transfer over a carrier-grade dense-wavelength-division-multiplexing (DWDM) optical fibre network are presented. The relation between soil temperature changes on a buried optical fibre and frequency changes of an optical carrier through the fibre is modelled. Soil temperatures, measured at various depths by the Royal Netherlands Meteorology Institute (KNMI) are compared with observed frequency variations through this model. A comparison of a nine-day record of optical frequency measurements through the 2 x 298 km fibre link with soil temperature data shows qualitative agreement. A soil temperature model is used to predict the link stability over longer periods (days-months-years). We show that one-way optical frequency dissemination is sufficiently stable to distribute and compare e.g. rubidium frequency standards over standard DWDM optical fibre networks.

  15. A compact 1×64 optical power splitter using silica-based PLC on quartz substrate

    Science.gov (United States)

    Wang, Liangliang; An, Junming; Wu, Yuanda; Wang, Yue; Zhang, Jiashun; Li, Jianguang; Wang, Hongjie; Zhang, Xiaoguang; Pan, Pan; Dai, Hongqing; Qi, Ying; Zhong, Fei; Zha, Qiang; Hu, Xiongwei; Zhao, Degang

    2014-09-01

    In this paper, a compact and low wavelength-dependence loss (WDL) 1×64 optical power splitter is fabricated using silica-based PLC technology on quartz substrate. The cascaded Y-branch structures are optimized in detail, and a compact 1×64 optical power splitter layout is obtained. The measured results show that the insertion loss (IL), the uniformity and WDL of the best results of all splitters are less than 19.2 dB, 1.0 dB and 0.5 dB, respectively, in the wavelength range from 1.26 μm to 1.65 μm, and the total product ratio of Standard grade in a whole 6 in. wafer is more than 80%. The results imply that our technology completely satisfies the need of mass manufacture.

  16. Optical fibre dosemeter systems for clinical applications based on radioluminescence and optically stimulated luminescence from Al2O3:C

    DEFF Research Database (Denmark)

    Marckmann, C.J.; Andersen, C.E.; Aznar, M.C.

    2006-01-01

    Optical fibre dosemeter systems based on radioluminescence and optically stimulated luminescence (OSL) from carbon-doped aluminium oxide (Al2O3:C) crystals were developed for in vivo real-time dose rate and absorbed dose measurements in radiotherapy and mammography. A technique was also developed...... for making ultra-small dosemeter probes that can easily be placed inside patients in radiation treatment. These probes have shown excellent properties in both head and neck intensity-modulated radiation therapy treatment and in mammography. The dose-response of the OSL signal for the new optical fibre...

  17. Characteristics and stability of soliton crystals in optical fibres for the purpose of optical frequency comb generation

    Science.gov (United States)

    Zajnulina, M.; Böhm, M.; Bodenmüller, D.; Blow, K.; Boggio, J. M. Chavez; Rieznik, A. A.; Roth, M. M.

    2017-06-01

    We study the properties of a soliton crystal, a bound state of several optical pulses that propagate with a fixed temporal separation through the optical fibres of the proposed approach for generation of optical frequency combs (OFC) for astronomical spectrograph calibration. This approach - also being suitable for subpicosecond pulse generation for other applications - consists of a conventional single-mode fibre and a suitably pumped Erbium-doped fibre. Two continuous-wave lasers are used as light source. The soliton crystal arises out of the initial deeply modulated laser field at low input powers; for higher input powers, it dissolves into free solitons. We study the soliton crystal build-up in the first fibre stage with respect to different fibre parameters (group-velocity dispersion, nonlinearity, and optical losses) and to the light source characteristics (laser frequency separation and intensity difference). We show that the soliton crystal can be described by two quantities, its fundamental frequency and the laser power-threshold at which the crystal dissolves into free solitons. The soliton crystal exhibits features of a linear and nonlinear optical pattern at the same time and is insensitive to the initial laser power fluctuations. We perform our studies using the numerical technique called Soliton Radiation Beat Analysis.

  18. A Dual Sensor for pH and Hydrogen Peroxide Using Polymer-Coated Optical Fibre Tips

    Directory of Open Access Journals (Sweden)

    Malcolm S. Purdey

    2015-12-01

    Full Text Available This paper demonstrates the first single optical fibre tip probe for concurrent detection of both hydrogen peroxide (H2O2 concentration and pH of a solution. The sensor is constructed by embedding two fluorophores: carboxyperoxyfluor-1 (CPF1 and seminaphtharhodafluor-2 (SNARF2 within a polymer matrix located on the tip of the optical fibre. The functionalised fibre probe reproducibly measures pH, and is able to accurately detect H2O2 over a biologically relevant concentration range. This sensor offers potential for non-invasive detection of pH and H2O2 in biological environments using a single optical fibre.

  19. A Tuning Fork with a Short Fibre Probe Sensor for a Near-FieldScanning Optical Microscope

    Institute of Scientific and Technical Information of China (English)

    王沛; 鲁拥华; 章江英; 明海; 谢建平; 黄建文; 高宗圣; 蔡定平

    2002-01-01

    We report on a tapping-mode tuning fork with a short fibre probe sensor for a near-field scanning optical microscope. The method demonstrates how to fabricate the short fibre probe. This tapping-mode tuning fork with a short fibre probe can provide stable and high Q at the tapping frequency of the tuning fork, and can give high-quality near-field scanning optical microscope and atomic force microscope images of samples. We present the results of using the tapping-mode tuning fork with a short fibre probe sensor for a near-field scanning optical microscope performed on an eight-channel silica waveguide.

  20. Real-time dosimetry with Yb-doped silica optical fibres

    Science.gov (United States)

    Veronese, Ivan; Chiodini, Norberto; Cialdi, Simone; d'Ippolito, Eduardo; Fasoli, Mauro; Gallo, Salvatore; La Torre, Stefano; Mones, Eleonora; Vedda, Anna; Loi, Gianfranco

    2017-05-01

    Over the years, many efforts have been made to develop radiation detectors to handle the complex issues of small field dosimetry and achieve the increasing accuracy, precision and in vivo dose monitoring required by the new advanced treatment modalities. In this context, interest has surged in the development of sensors based on scintillating optical fibres. In this paper, the near-infrared radioluminescence and dosimetric properties of Yb-doped silica optical fibres, coupled with a laboratory prototype based on an avalanche photodiode, were studied by irradiating the fibres with photons and electron beams generated by a Varian Trilogy accelerator. The performance of the system in standard and small field sizes has also been investigated, comparing the output factor, percentage depth dose and off-axis ratio measurements of the prototypal detector with other commercial sensors, including the Exradin W1 scintillator. The results of this study demonstrate that the drawback due to the stem effect in Yb-doped silica optical fibres can be managed in a simple but effective way by optical filtering. The robustness of the system in complex dosimetric scenarios and the accuracy and precision achieved by Yb-doped fibres in relative dose assessments suggest an effective use of the system for real-time in vivo dosimetry applications.

  1. Early dental caries detection using a fibre-optic coupled polarization-resolved Raman spectroscopic system.

    Science.gov (United States)

    Ko, Alex C-T; Hewko, Mark; Sowa, Michael G; Dong, Cecilia C S; Cleghorn, Blaine; Choo-Smith, Lin-P'ing

    2008-04-28

    A new fibre-optic coupled polarization-resolved Raman spectroscopic system was developed for simultaneous collection of orthogonally polarized Raman spectra in a single measurement. An application of detecting incipient dental caries based on changes observed in Raman polarization anisotropy was also demonstrated using the developed fibre-optic Raman spectroscopic system. The predicted reduction of polarization anisotropy in the Raman spectra of caries lesions was observed and the results were consistent with those reported previously with Raman microspectroscopy. The capability of simultaneous collection of parallel- and cross-polarized Raman spectra of tooth enamel in a single measurement and the improved laser excitation delivery through fibre-optics demonstrated in this new design illustrates its future clinical potential.

  2. Fatigue Damage Monitoring of a Composite Step Lap Joint Using Distributed Optical Fibre Sensors

    Directory of Open Access Journals (Sweden)

    Leslie Wong

    2016-05-01

    Full Text Available Over the past few decades, there has been a considerable interest in the use of distributed optical fibre sensors (DOFS for structural health monitoring of composite structures. In aerospace-related work, health monitoring of the adhesive joints of composites has become more significant, as they can suffer from cracking and delamination, which can have a significant impact on the integrity of the joint. In this paper, a swept-wavelength interferometry (SWI based DOFS technique is used to monitor the fatigue in a flush step lap joint composite structure. The presented results will show the potential application of distributed optical fibre sensor for damage detection, as well as monitoring the fatigue crack growth along the bondline of a step lap joint composite structure. The results confirmed that a distributed optical fibre sensor is able to enhance the detection of localised damage in a structure.

  3. Fabrication and Sensing Performance of Smart Composite Structures Using Optical Fibre Sensors

    Institute of Scientific and Technical Information of China (English)

    C Y Wei; S W James; C C Ye; R P Tatam; P E lrving

    2000-01-01

    This paper determines the performance of Fibre Bragg Grating (FBG) sensors for strain sensing applications in carbon fibre composite materials. Carbon fibre laminates in either cross-plied or quasiisotropic stacking sequences were fabricated using T300/Hexcel 914 prepregs. The FBG optical sensors were either surface attached, or embedded within laminates. The sensor orientation was aligned either parallel or transverse to the adjacent carbon fibre layers. The composite structures with integrated FBG sensors were subjected to static tensile loading. A scanning fibre Fabry-Perot filter was used to monitor the reflected Bragg wavelengths. The optical sensor embedded between two 90° carbon fibre plies shows a high sensitivity to multi-site cracking formed in the transverse plies. The embedding in 90° plies seems to change the local stress distributions and to become a source of crack initiation. Efficient stress transfer from the host materials to the sensors is dependent upon incorporation methods, the thickness of the adhesive layers, and the location of the sensors.

  4. Reflective variable optical attenuators and fibre ring lasers for wavelength-division multiplexing systems

    Science.gov (United States)

    Liu, He Liang

    Wavelength division multiplexing (WDM) optical fibre system is an important enabling technology to fulfill the demands for bandwidth in the modern information age. The main objective of this project is to study novel devices with the potential to enhance the performance of WDM systems. In particular, a novel reflective variable optical attenuator (RVOA) used for dynamic gain equalization (DGE) and fibre lasers based on an entirely new type of erbium-doped fibres with ultrawide tuning range were investigated theoretically and experimentally. We proposed a new type of RVOA device which could be potentially integrated with arrayed waveguide grating (AWG) to reduce the cost of DGE substantially. Initially, fibre-based RVOAs, fabricated with optical fibre components such as fibre coupler and Faraday rotator mirror, were investigated theoretically and experimentally. Larger attenuation range up to 22 dB was realized for fibre coupler-based ROVA with a Faraday rotator mirror and its polarization-dependent loss is about 0.5 dB. Then polymeric waveguide-based RVOAs were investigated theoretically and experimentally. Using an epoxy Novolak resin as core material and an UV-cured resin (Norland's NOA61) as cladding material, a polymeric waveguide RVOA was successfully fabricated. The dynamic 15 dB attenuation range was achieved and the PDL was less than 0.2 dB. The measured insertion loss of the polymeric waveguide RVOA was too large (about 18 dB) and was mainly induced by coupling loss, material loss and poor alignment. In the second part of the study, fibre ring lasers with continuous wavelength tuning over wide wavelength range and fibre ring lasers with discrete wavelength tuning were investigated. Tunable lasers are important devices in WDM systems because they could be employed as reserved sources and therefore avoiding the need to stock large inventory of lasers to cover the ITU-wavelength grid. In this project, erbium ions doped bismuth oxide glass fibres instead of

  5. Optic nerve head and fibre layer imaging for diagnosing glaucoma

    Science.gov (United States)

    Michelessi, Manuele; Lucenteforte, Ersilia; Oddone, Francesco; Brazzelli, Miriam; Parravano, Mariacristina; Franchi, Sara; Ng, Sueko M; Virgili, Gianni

    2016-01-01

    Background The diagnosis of glaucoma is traditionally based on the finding of optic nerve head (ONH) damage assessed subjectively by ophthalmoscopy or photography or by corresponding damage to the visual field assessed by automated perimetry, or both. Diagnostic assessments are usually required when ophthalmologists or primary eye care professionals find elevated intraocular pressure (IOP) or a suspect appearance of the ONH. Imaging tests such as confocal scanning laser ophthalmoscopy (HRT), optical coherence tomography (OCT) and scanning laser polarimetry (SLP, as used by the GDx instrument), provide an objective measure of the structural changes of retinal nerve fibre layer (RNFL) thickness and ONH parameters occurring in glaucoma. Objectives To determine the diagnostic accuracy of HRT, OCT and GDx for diagnosing manifest glaucoma by detecting ONH and RNFL damage. Search methods We searched several databases for this review. The most recent searches were on 19 February 2015. Selection criteria We included prospective and retrospective cohort studies and case-control studies that evaluated the accuracy of OCT, HRT or the GDx for diagnosing glaucoma. We excluded population-based screening studies, since we planned to consider studies on self-referred people or participants in whom a risk factor for glaucoma had already been identified in primary care, such as elevated IOP or a family history of glaucoma. We only considered recent commercial versions of the tests: spectral domain OCT, HRT III and GDx VCC or ECC. Data collection and analysis We adopted standard Cochrane methods. We fitted a hierarchical summary ROC (HSROC) model using the METADAS macro in SAS software. After studies were selected, we decided to use 2 × 2 data at 0.95 specificity or closer in meta-analyses, since this was the most commonly-reported level. Main results We included 106 studies in this review, which analysed 16,260 eyes (8353 cases, 7907 controls) in total. Forty studies (5574

  6. On-line determination of fatty acid composition in intramuscular fat of Iberian pork loin by NIRs with a remote reflectance fibre optic probe.

    Science.gov (United States)

    González-Martín, I; González-Pérez, C; Alvarez-García, N; González-Cabrera, J M

    2005-02-01

    A near infrared spectrometer equipped with a standard 210/210 bundle remote reflectance fibre-optic probe, with a 5×5 cm quartz window type, was used for the determination of fatty acids in the Longissimus dorsi muscle of Iberian breed swine. The fatty acids C14:0, C16:0, C16:1, C17:0, C17:1, C18:0, C18:1, C18:2, C18:3, Σpolyunsaturated, Σmonounsaturated and Σsaturated were determined in samples of intramuscular fat from Iberian breed swine by direct application of the fibre-optic probe onto the loin sample, with no treatment or manipulation of the sample. The regression method employed was modified partial least squares. The calibration results using the fibre-optic probe for 74 loin samples had multiple correlation coefficients (RSQ) for C14:0, C16:0, C16:1, C17:0, C17:1, C18:0, C18:1, C18:2, C18:3, Σpolyunsaturated, Σmonounsaturated and Σsaturated acid of 0.785, 0.798, 0.788, 0.825, 0.762, 0.765, 0.696, 0.859, 0.878, 0.807, 0.943, 0.858, respectively, and standard errors of prediction corrected for the same fatty acids (%) of 0.08, 0.63, 0.26, 0.02, 0.02, 0.51, 0,77, 0.64, 0.05, 1.06, 0.34, 0.70, respectively. The robustness of the method was checked by applying the fibre-optic probe to unknown samples of Iberian breed pork loin in a slaughterhouse, using 15 samples for the external validation.

  7. An integrating sphere radiometer as a solution for high power calibrations in fibre optics

    Science.gov (United States)

    Carrasco-Sanz, Ana; Rodríguez-Barrios, Félix; Corredera, Pedro; Martín-López, Sonia; González-Herráez, Miguel; Hernanz, María Luisa

    2006-04-01

    This paper describes the design, characterization and calibration of a high power transfer standard for optical power measurements in optical fibres based on an integrating sphere radiometer. This radiometer, based on two detectors (Si and InGaAs), can measure powers between 100 nW and 10 W within the wavelength range of (400-1700) nm. The radiometer has been calibrated over the total spectral range of use against an electrically calibrated pyroelectric radiometer and different fibre laser diodes and ion lasers. The total uncertainty obtained is lower than ±1.5% for these wavelengths and power ranges (excluding the water absorption region).

  8. Design of a fibre-optic disc accelerometer: theory and experiment

    Science.gov (United States)

    Wang, Yongjie; Xiao, Hao; Zhang, Songwei; Li, Fang; Liu, Yuliang

    2007-06-01

    Mechanical principles of fibre-optic disc accelerometers (FODA) different from those assumed in previous calculation methods are presented. An FODA with a high sensitivity of 82 rad/g and a resonance frequency of 360 Hz is designed and tested. In this system, the minimum measurable demodulation phase of the phase-generated carrier (PGC) is 10-5 rad, and the minimum acceleration reaches 120 ng theoretically. This kind of FODA, with its high responsivity, all-optic-fibre configuration, small size, light weight and stiff shell housing, ensures effective performance in practice.

  9. Flavin and porphyrin-micro optical fibre biosensor: analysis and design

    Science.gov (United States)

    Velazquez-Gonzalez, J. S.; Mujica-Ascencio, S.; Aguilar Morales, A. I.; Marrujo-Garcia, S.; Alvarez-Chavez, J. A.; Martinez-Pinon, F.

    2014-05-01

    Micro Optical Fibre Biosensors (MOFBs) are emerging as one of the most sensitive bio-detection system technologies which do not require of labelling or amplification of the analyte. In these devices, a short region of the fibre core is exposed to the external environment so that the evanescent field can interact with biological species such as cells, proteins, and DNA. In order to increase the sensitivity and selectivity, MOFBs are often used in combination with other optical transduction mechanisms such as changes in refractive index, absorption, fluorescence and surface plasmon resonance. In this work we present the full characteristics, analysis and design of a MOFBs for Flavin and Porphyrin detection.

  10. Addressing the needs of the telecoms industry for optical fibre communication in Africa

    Science.gov (United States)

    Leitch, Andrew W. R.; Conibear, Ann B.

    2005-10-01

    We report on a successful partnership between the Department of Physics at the Nelson Mandela Metropolitan University (NMMU) and Telkom, South Africa's national telecommunications company, to train physics students in the important fields related to optical fibre technology. The partnership, which began in 2001 and forms part of Telkom's Centre of Excellence program in South Africa, is currently being extended to other countries in Africa. The training being conducted in the Physics Department has as one of its main goals an increased understanding of polarisation mode dispersion (PMD), an effect that will ultimately limit the transmission speeds through optical fibre.

  11. Forty-Four Pass Fibre Optic Loop for Improving the Sensitivity of Surface Plasmon Resonance Sensors

    CERN Document Server

    Su, Chin B

    2007-01-01

    A forty-four pass fibre optic surface plasmon resonance sensor that enhances detection sensitivity according to the number of passes is demonstrated for the first time. The technique employs a fibre optic recirculation loop that passes the detection spot forty- four times, thus enhancing sensitivity by a factor of forty-four. Presently, the total number of passes is limited by the onset of lasing action of the recirculation loop. This technique offers a significant sensitivity improvement for various types of plasmon resonance sensors that may be used in chemical and biomolecule detections.

  12. The duration of fibre-optic intubation is increased by cricoid pressure. A randomised double-blind study

    DEFF Research Database (Denmark)

    Arenkiel, Bjørn; Smitt, M; Olsen, K S

    2013-01-01

    In some categories of patients, a rapid sequence induction using a fibre-optic method may be indicated. The aim of the present study was to examine the effect of cricoid pressure (CP) on the duration of fibre-optic intubation. The hypothesis was that CP would prolong the intubation time....

  13. Fibre optic Bragg grating sensors: an alternative method to strain gauges for measuring deformation in bone.

    Science.gov (United States)

    Fresvig, T; Ludvigsen, P; Steen, H; Reikerås, O

    2008-01-01

    Strain gauges are currently the default method for measuring deformation in bone. Strain gauges are not well suited for in vivo measurements because of their size and because they are difficult to use in bone. They are also unsuitable for repeated measurements over time since they cannot be left in the patient. The optical Bragg grating fibres behave like selective filters of light. As a result the structure will transmit most wavelengths of light, but will reflect certain specific wavelengths. If the Bragg grating is strained along the fibre axis, the wavelength will shift, and this change represents a measure of strain. The optical fibres are very thin, no thicker than a standard surgical suture and are easy to adhere to bone by use of the FDA approved polymethyl-methacrylate (PMMA) as bonding adhesive. Since they are made of biocompatible silica porous bioglass ceramics, it should also be possible to leave the fibres in the patient between and after measurements. We have shown that fibre optic Bragg grating sensors can be used as a measurement tool for bone strain by performing measurements both on an acryl tube and on an extracted sample of human femur diaphysis. On either of them we used four fibre optic sensors and four strain gauges, interspersed at every 45 degrees around the circumference. The standard deviation of the measurements on the acrylic tube for each of the sensors, both optical fibres and strain gauges, varied from 1.0 to 5.2%. Every sensor, both optical fibre and strain gauge, correlated significantly with all of the rest at the 0.01 level with a Pearson correlation coefficient r ranging from 0.986 to 1.0. The linearity for all of the sensors versus load was excellent, the lowest linearity of the eight sensors was 0.996 as expressed by r(2) (coefficient of determination), with no significant difference in linearity between optical fibres and strain gauges. Bone is not an ideal isotropic material, and we found that the strain readings of the

  14. Preliminary evaluation of a new fibre-optic cerebral oximetry system.

    Science.gov (United States)

    Phillips, J P; Langford, R M; Kyriacou, P A; Jones, D P

    2008-12-01

    A new system for measuring the oxygen saturation of blood within tissue has been developed, for a variety of patient monitoring applications. A particular unmet need is in the central nervous system, and this project aims to devise a means for measuring blood oxygen saturation in the brain tissue of patients recovering from neurosurgery or head injury. Coupling light sources and a photodetector to optical fibres results in a probe small enough to pass through a cranial bolt of the type already in use for intra-cranial pressure monitoring. The development and evaluation of a two-wavelength fibre-optic reflectance photoplethysmography (PPG) system are described. It was found that good quality red and near-infrared PPG signals could be obtained from the finger using a fibre-optic probe. Experiments were conducted to find the inter-fibre spacings that yield signals most suitable for calculating oxygen saturation. Reliable signals could be obtained for inter-fibre spacings between 2 mm and 5 mm, the latter being the size of the maximum aperture in the cranial bolt. A preliminary measurement from human brain tissue is also presented.

  15. Fibre optic sensor for the detection of adulterant traces in coconut oil

    Science.gov (United States)

    Sheeba, M.; Rajesh, M.; Vallabhan, C. P. G.; Nampoori, V. P. N.; Radhakrishnan, P.

    2005-11-01

    The design and development of a fibre optic evanescent wave refractometer for the detection of trace amounts of paraffin oil and palm oil in coconut oil is presented. This sensor is based on a side-polished plastic optical fibre. At the sensing region, the cladding and a small portion of the core are removed and the fibre nicely polished. The sensing region is fabricated in such a manner that it sits perfectly within a bent mould. This bending of the sensing region enhances its sensitivity. The oil mixture of different mix ratios is introduced into the sensing region and we observed a sharp decrease in the output intensity. The observed variation in the intensity is found to be linear and the detection limit is 2% (by volume) paraffin oil/palm oil in coconut oil. The resolution of this refractometric sensor is of the order of 10-3. Since coconut oil is consumed in large volumes as edible oil in south India, this fibre optic sensor finds great relevance for the detection of adulterants such as paraffin oil or palm oil which are readily miscible in coconut oil. The advantage of this type of sensor is that it is inexpensive and easy to set up. Another attraction of the side-polished fibre is that only a very small amount of analyte is needed and its response time is only 7 s.

  16. Optical transmission of PMMA optical fibres exposed to high intensity UVA and visible blue light

    Science.gov (United States)

    Alobaidani, A. D.; Furniss, D.; Johnson, M. S.; Endruweit, A.; Seddon, A. B.

    2010-05-01

    Optical transmission of PMMA (polymethylmethacrylate) POF (polymer optical fibre) in the spectral range from 280 to 450 nm is investigated with a high radiation emission source comprising a mercury lamp delivering 40 W/cm 2 at the PMMA POF launch face. The heat generated from the radiation source causes a sudden drop in the launched radiation due to thermal-oxidation and photo-degradation of the launch face of the PMMA POF; this results in a loss of 53% of the total launched power within 13 min of exposure to the source. The thermal-oxidation degradation is controlled by a cooling device which improves the transmission stability of the fibre. However, photo-degradation is still active and causes a loss in power of 7% in 13 min. The spectral output of the transmitted radiation through the PMMA POF was monitored and indicates the variation in optical loss with wavelength. High rates of nominal absorption for the irradiated PMMA POF are found below 320 nm wavelength. From the Beer-Lambert law, the photo-degradation effect with time of a fixed path length of PMMA POF is described by the absorption coefficient ( αλ, cm -1) . The nominal absorption coefficient αλ values in the range 335-368 nm wavelength are found to be higher after 1 h of irradiation than the values in the range 406-438 nm. However, the relative change in the nominal absorption coefficient Δ αλ is greater at 438 nm than at 335 nm, 368 or 406 nm. After 1 h of irradiation with the cooling device in place, the PMMA POF transmission was reduced to 44.8% of its initial value; this recovered to a maximum of 86% of the original transmission of the total launched power after 5 weeks in ambient conditions.

  17. Fibre-optic UV systems for gas and vapour analysis

    Energy Technology Data Exchange (ETDEWEB)

    Eckhardt, H S [University of Applied Sciences Giessen-Friedberg, Wilhelm-Leuschner-Str, 13, 61169 Friedberg (Germany); Klein, K-F [University of Applied Sciences Giessen-Friedberg, Wilhelm-Leuschner-Str, 13, 61169 Friedberg (Germany); Spangenberg, B [University of Applied Sciences Offenburg, Badstrasse 24, 77652 Offenburg (Germany); Sun, T [City University London, Northampton Square, London, EC1V 0HB (United Kingdom); Grattan, K T V [City University London, Northampton Square, London, EC1V 0HB (United Kingdom)

    2007-10-15

    The identification and quantification of compounds in the gas phase becomes of increasing interest in the context of environmental protection, as well as in the analytical field. In this respect, the high extinction coefficients of vapours and gases in the ultraviolet wavelength region allow a very sensitive measurement system. In addition, the increased performance of the components necessary for setting up a measurement system, such as fibres, light sources and detectors has been improved. In particular the light sources and detectors offer improved stability, and the deep UV performance and solarisation resistance of fused silica fibres allow have been significantly optimized in the past years. Therefore a compact and reliable detection system with high measuring accuracy is developed. Within this paper possible applications of the system under development and recent results will be discussed.

  18. Scintillation Particle Detectors Based on Plastic Optical Fibres and Microfluidics

    CERN Document Server

    Mapelli, Alessandro; Renaud, Philippe

    2011-01-01

    This thesis presents the design, development, and experimental validation of two types of scintillation particle detectors with high spatial resolution. The first one is based on the well established scintillating fibre technology. It will complement the ATLAS (A Toroidal Large ApparatuS) detector at the CERN Large Hadron Collider (LHC). The second detector consists in a microfabricated device used to demonstrate the principle of operation of a novel type of scintillation detector based on microfluidics. The first part of the thesis presents the work performed on a scintillating fibre tracking system for the ATLAS experiment. It will measure the trajectory of protons elastically scattered at very small angles to determine the absolute luminosity of the CERN LHC collider at the ATLAS interaction point. The luminosity of an accelerator characterizes its performance. It is a process-independent parameter that is completely determined by the properties of the colliding beams and it relates the cross section of a ...

  19. Propagation of Single-Mode Fibre Laser Beams through an Optical ABCD System with Circular Aperture at the Fibre Output End

    Institute of Scientific and Technical Information of China (English)

    DUAN Sai-Liang; LI Jian-Feng; ZHAO Wei; WANG Yi-Shan

    2008-01-01

    @@ Based on the expansion expression of the fundamental mode of a single-mode fibre in terms of Laguerre-Gauss modes, the propagation of a beam of a weakly guiding fibre laser through an optical ABCD system with a circular aperture at the fibre end is studied. The results show that there is much difference between the propagation of the laser beam described by the expansion expression and by the Gaussian mode approximation. The depth of focus of the laser beam is longer than that of the Gaussian modes.

  20. A simple model for fibre optics: planar dielectric waveguides in rotation

    Energy Technology Data Exchange (ETDEWEB)

    Perez-Ocon, F [Departamento de Optica, Universidad de Granada, 18071 Granada (Spain); Pena, A [Valeo Iluminacion, 23600 Martos, Jaen (Spain); Jimenez, J R [Departamento de Optica, Universidad de Granada, 18071 Granada (Spain); Diaz, J A [Departamento de Optica, Universidad de Granada, 18071 Granada (Spain)

    2006-05-01

    In planar dielectric waveguides, there is only one type of propagated ray: the one that crosses the waveguide axis after each total internal reflection. According to the model of geometrical optics, there are two types of guided ray in fibre optics: meridional and skew. Each one is formulated by a suitable mathematical treatment. In this work, we demonstrate that the complex mathematical treatment for the skew rays can be avoided by considering a planar waveguide (with the same refractive index profile as the fibre and thickness equal to its diameter) that rotates around the direction of the axis with angular velocity {omega}. A section of this fibre is inscribed in the hypothetical slab. This model has been successfully introduced to students of engineering and physics.

  1. Fibre-optic coupling to high-resolution CCD and CMOS image sensors

    Science.gov (United States)

    van Silfhout, R. G.; Kachatkou, A. S.

    2008-12-01

    We describe a simple method of gluing fibre-optic faceplates to complementary metal oxide semiconductor (CMOS) active pixel and charge coupled device (CCD) image sensors and report on their performance. Cross-sectional cuts reveal that the bonding layer has a thickness close to the diameter of the individual fibres and is uniform over the whole sensor area. Our method requires no special tools or alignment equipment and gives reproducible and high-quality results. The method maintains a uniform bond layer thickness even if sensor dies are mounted at slight angles with their package. These fibre-coupled sensors are of particular interest to X-ray imaging applications but also provide a solution for compact optical imaging systems.

  2. Remote Key Establishment by Mode Mixing in Multimode Fibres and Optical Reciprocity

    CERN Document Server

    Bromberg, Yaron; Popoff, Sebastien M; Cao, Hui

    2015-01-01

    Disorder and scattering in photonic systems have long been considered a nuisance that should be circumvented. Recently, disorder has been harnessed for a rapidly growing number of applications, including imaging, sensing and spectroscopy. The chaotic dynamics and extreme sensitivity to external perturbations make random media particularly well-suited for optical cryptography. However, using random media for distribution of secret keys between remote users still remains challenging, since it requires the users have access to the same scattering system. Here we utilize random mode mixing in multimode fibres to generate and distribute keys simultaneously. Fast fluctuations in the fibre mode mixing provide the source of randomness for the key generation, and optical reciprocity guarantees that the keys at the two ends of the fibre are identical. We experimentally demonstrate the scheme using classical light and off-the-shelf components, opening the door for cost effective key establishment at the physical-layer o...

  3. A fibre optic sensor for the in situ determination of rock physical properties

    CERN Document Server

    Reinsch, Thomas; Milsch, Harald; Bremer, Kort; Lewis, Elfed; Leen, Gabriel; Lochmann, Steffen; 10.1016/j.ijrmms.2012.06.011

    2012-01-01

    To understand the behaviour of rocks under changing load or temperature conditions, the determination of physical parameters like pore pressure or temperature within the pore space is essential. Within this study, the implementation of a novel fibre optic point sensor for pressure and temperature determination into a high pressure / high temperature triaxial cell is presented. For the first time, pressure was measured directly within the pore space of a Flechtinger sandstone specimen during a hydrostatic compression test at up to 70 MPa. The sensor used within this study consists of a miniature all-silica fibre optic Extrinsic Fabry-Perot Interferometer (EFPI) sensor which has an embedded Fibre Bragg Grating (FBG) reference sensor element to determine temperature and pressure directly at the point of measurement.

  4. Secure Communication System Based on Chaos in Optical Fibre

    Institute of Scientific and Technical Information of China (English)

    Pak; L; Chu; Fan; Zhang; William; Mak; Robust; Lai

    2003-01-01

    1 IntroductionRecently, there have been intense research activities on the study of synchronized chaos generated by fibre lasers and its application to secure communication systems. So far, all studies concentrate on two aspects: (1) the effect of the transmission channel between the transmitter and the receiver has been neglected, and (2) the chaos and the signal are carried by one wavelength. Both theoretical and experimental investigations make

  5. CONFERENCE NOTE: CETO—Centro de Ciências e Tecnologias Opticas, Trends in Optical Fibre Metrology and Standards

    Science.gov (United States)

    1994-01-01

    Summer School, 27 June to 8 July 1994, Viana do Castelo, Hotel do Parque, Portugal Optical fibres, with their extremely low transmission loss, untapped bandwidth and controllable dispersion, dominate a broad range of technologies in which applications must respond to the increasing constraints of today's specifications as well as envisage future requirements. Optical fibres dominate communications systems. In the area of sensors, fibre optics will be fully exploited for their immunity to EMI, their high sensitivity and their large dynamic range. The maturity of single mode optical technology has led to intensive R&D of a range of components based on the advantages of transmission characteristics and signal processing. Specifications and intercompatibility requests for the new generation of both analogue and digital fibre optical components and systems has created a demand for sophisticated measuring techniques based on unique and complex instruments. In recent years there has been a signification evolution in response to the explosion of applications and the tightening of specifications. These developments justify a concerted effort to focus on trends in optical fibre metrology and standards. Objective The objective of this school is to provide a progressive and comprehensive presentation of current issues concerning passive and active optical fibre characterization and measurement techniques. Passive fibre components support a variety of developments in optical fibre systems and will be discussed in terms of relevance and standards. Particular attention will be paid to devices for metrological purposes such as reference fibres and calibration artefacts. The characterization and testing of optical fibre amplifiers, which have great potential in telecommunications, data distribution networks and as a system part in instrumentation, will be covered. Methods of measurement and means of calibration with traceability will be discussed, together with the characterization

  6. Investigating quartz optically stimulated luminescence dose-response curves at high doses

    Energy Technology Data Exchange (ETDEWEB)

    Lowick, Sally E., E-mail: lowick@geo.unibe.c [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Preusser, Frank [Institut fuer Geologie, Universitaet Bern, Baltzerstrasse 1-3, 3012 Bern (Switzerland); Wintle, Ann G. [Institute of Geography and Earth Sciences, Aberystwyth University, AberystwythSY23 3DB (United Kingdom)

    2010-10-15

    Despite the general expectation that optically stimulated luminescence (OSL) growth should be described by a simple saturating exponential function, an additional high dose component is often reported in the dose response of quartz. Although often reported as linear, it appears that this response is the early expression of a second saturating exponential. While some studies using equivalent doses that fall in this high dose region have produced ages that correlate well with independent dating, others report that it results in unreliable age determinations. Two fine grain sedimentary quartz samples that display such a response were used to investigate the origin of this additional high dose component: three experiments were conducted to examine their dose-response up to >1000 Gy. The high dose rates provided by laboratory irradiation were found not to induce a sensitivity change in the response to a subsequent test dose, with the latter not being significantly different from those generated following naturally acquired doses. The relative percentage contributions of the fast and medium OSL components remained fixed throughout the dose-response curve, suggesting that the electron traps that give rise to the initial OSL do not change with dose. An attempt was made to investigate a change in luminescence centre recombination probability by monitoring the depletion of the '325 {sup o}C' thermoluminescence (TL) during the optical stimulation that would result in depletion of the OSL signal. The emissions measured through both the conventional ultraviolet (UV), and a longer wavelength violet/blue (VB) window, displayed similar relative growth with dose, although it was not possible to resolve the origin of the VB emissions. No evidence was found to indicate whether the additional component at high doses occurs naturally or is a product of laboratory treatment. However, it appears that these samples display an increased sensitivity of quartz OSL to high doses

  7. Optical properties of PLT films with various composition on quartz and modifications of their surfaces

    CERN Document Server

    Yoon, Y S; Koh, S K; Jung, H J

    1999-01-01

    (Pb sub 1 sub - sub x La sub x)TiO sub 3 (PLT) films with various compositions of La were deposited by using the sol-gel process on quartz substrates in order to study their optical properties. X-ray patterns indicated that the pseudocubic phase of the PLT film dominated with increased La concentration due to a decrease in the lattice constant of the c-axis. Three-dimensional atomic force microscopy images revealed that the grain size and root mean square (r.m.s) surface roughness were decreased by adding of La. The optical band gap of the as-deposited films became wider when Pb was replaced with La, which could be calculated from the transmittance of an UV-visible spectrometer. The addition of La increased the transparency of the PbTiO sub 3 film and shifted the threshold to shorter wavelengths for initiation of absorption. In addition, we modified the surfaces of the PLT films with La concentrations of 5 % by using an oxygen-ion beam with an oxygen-ion energy of 1 kV at different doses. The optical band gap...

  8. Deformation Measurement of a Driven Pile Using Distributed Fibre-optic Sensing

    Science.gov (United States)

    Monsberger, Christoph; Woschitz, Helmut; Hayden, Martin

    2016-03-01

    New developments in distributed fibre-optic sensing allow the measurement of strain with a very high precision of about 1 µm / m and a spatial resolution of 10 millimetres or even better. Thus, novel applications in several scientific fields may be realised, e. g. in structural monitoring or soil and rock mechanics. Especially due to the embedding capability of fibre-optic sensors, fibre-optic systems provide a valuable extension to classical geodetic measurement methods, which are limited to the surface in most cases. In this paper, we report about the application of an optical backscatter reflectometer for deformation measurements along a driven pile. In general, pile systems are used in civil engineering as an efficient and economic foundation of buildings and other structures. Especially the length of the piles is crucial for the final loading capacity. For optimization purposes, the interaction between the driven pile and the subsurface material is investigated using pile testing methods. In a field trial, we used a distributed fibre-optic sensing system for measuring the strain below the surface of an excavation pit in order to derive completely new information. Prior to the field trial, the fibre-optic sensor was investigated in the laboratory. In addition to the results of these lab studies, we briefly describe the critical process of field installation and show the most significant results from the field trial, where the pile was artificially loaded up to 800 kN. As far as we know, this is the first time that the strain is monitored along a driven pile with such a high spatial resolution.

  9. Dense central office solution for point-to-point fibre access including a novel compact dual bi-directional fibre optical transceiver

    Science.gov (United States)

    Arvidsson, Gunnar; Junique, Stéphane; Persson, Karl-Åke; Sundberg, Erland

    2006-07-01

    The centralized Point-to-Point fibre access approach with a dedicated single mode optical fibre link connecting each customer to a Central Office (CO) has advantages regarding future-proofness, security, and simple and low-cost optical links and transceivers. The potential bottleneck in handling the large number of optical fibres that need to be terminated in the CO, and combined with optoelectronic components, has been studied within the IST 6th Framework Programme integrated project MUSE. The key parts in the CO are the passive cabinet where customer fibres are accessible through fibre connectors in the Optical Distribution Frame (ODF), and the active cabinet with switching equipment and optical transceivers. For the passive cabinet we conclude, that the most efficient solution is that each connection from the active cabinet to a customer passes only one ODF, and that small form factor connectors are used. For the active cabinet we have demonstrated the feasibility of an SFF-size module containing two bi-directional transceiver units by building and successfully testing a prototype, increasing the customer port density by a factor of two compared to commercial transceivers. The power consumption, which impacts power supply, cooling and cost, has been analyzed, and we propose measures to significantly decrease the power consumption.

  10. Comparative experiments between a conventional piezo hydrophone system and a fibre optic hydrophone system

    NARCIS (Netherlands)

    Cheng, L.K.; Bruijn, D. de

    2000-01-01

    We report here the results of comparative measurements between Fibre Optic (FO) hydrophone system with our Hydrostatic Pressure Conmpensation (HPC) mechanism and a conventional piezo hydrophone system (consisting of an ITC 1042 hydrophone and a B&K2035 Analyser). The sensitivity and the dynamic rang

  11. Validation of an Endoscopic Fibre-Optic Pressure Sensor for Noninvasive Measurement of Variceal Pressure

    Directory of Open Access Journals (Sweden)

    Bin Sun

    2016-01-01

    Full Text Available In this study, the authors have developed endoscopic fibre-optic pressure sensor to detect variceal pressure and presented the validation of in vivo and in vitro studies, because the HVPG requires catheterization of hepatic veins, which is invasive and inconvenient. Compared with HVPG, it is better to measure directly the variceal pressure without puncturing the varices in a noninvasive way.

  12. Design and development of an experimental six component wind tunnel block balance using optical fibre sensors.

    CSIR Research Space (South Africa)

    De Ponte

    2014-05-01

    Full Text Available and manufacturing technologies. These are required to not only improve performance, but also to reduce production costs and lead times. This paper outlines the conceptual design of a six component block balance that uses Optical Fibre Bragg Grating (OFBG) sensors...

  13. Calibration of an experimental six component wind tunnel block balance using optical fibre sensors

    CSIR Research Space (South Africa)

    de Ponte

    2016-05-01

    Full Text Available and manufacturing technologies. These are required to not only improve performance, but also to reduce production costs and lead times. This paper outlines the design and evaluation of a six component block balance that uses Optical Fibre Bragg Grating (OFBG...

  14. 3-D printed sensing patches with embedded polymer optical fibre Bragg gratings

    DEFF Research Database (Denmark)

    Zubel, Michal G.; Sugden, Kate; Saez-Rodriguez, D.

    2016-01-01

    The first demonstration of a polymer optical fibre Bragg grating (POFBG) embedded in a 3-D printed structure is reported. Its cyclic strain performance and temperature characteristics are examined and discussed. The sensing patch has a repeatable strain sensitivity of 0.38 pm/mu epsilon. Its...

  15. Measuring the Dispersion Curve of a PMMA-Fibre Optic Cable Using a Dye Laser

    Science.gov (United States)

    Zorba, Serkan; Farah, Constantine; Pant, Ravi

    2010-01-01

    An advanced undergraduate laboratory experiment is outlined which uses a dye laser to map out the chromatic dispersion curve of a polymethyl methacrylate (PMMA) optical fibre. Seven different wavelengths across the visible spectrum are employed using five different dyes. The light pulse is split into two pulses, one to a nearby photodetector and…

  16. High-speed chaotic communication using an optical fibre ring as a key

    Institute of Scientific and Technical Information of China (English)

    Zou Lin; Feng Ye; Yang Yi-Biao; Wang An-Bang; Yang Ling-Zhen; Zhang Jian-Zhong

    2011-01-01

    A chaotic communication scheme with a fibre ring inserted in the optical feedback of the transmitter laser as an additional key is proposed under anticipating synchronization. The numerical results show that the key can enhance the communication security effectively. It is theoretically safe for the communication scheme to transmit messages with a frequency beyond the relaxation oscillation frequency.

  17. Bubble shape and orientation determination with a four-point optical fibre probe

    NARCIS (Netherlands)

    Guet, S.; Luther, S.; Ooms, G.

    2003-01-01

    We propose a new method to estimate the aspect ratio and orientation of bubbles by using their time series obtained with a four-point optical-fibre probe. The feasibility and accuracy of the method was first analysed by using synthetic bubble–probe interaction data and single bubble experiments in p

  18. Hybrid optical-fibre/geopolymer sensors for structural health monitoring of concrete structures

    Science.gov (United States)

    Perry, M.; Saafi, M.; Fusiek, G.; Niewczas, P.

    2015-04-01

    In this work, we demonstrate hybrid optical-fibre/geopolymer sensors for monitoring temperature, uniaxial strain and biaxial strain in concrete structures. The hybrid sensors detect these measurands via changes in geopolymer electrical impedance, and via optical wavelength measurements of embedded fibre Bragg gratings. Electrical and optical measurements were both facilitated by metal-coated optical fibres, which provided the hybrid sensors with a single, shared physical path for both voltage and wavelength signals. The embedded fibre sensors revealed that geopolymer specimens undergo 2.7 mɛ of shrinkage after one week of curing at 42 °C. After curing, an axial 2 mɛ compression of the uniaxial hybrid sensor led to impedance and wavelength shifts of 7 × 10-2 and -2 × 10-4 respectively. The typical strain resolution in the uniaxial sensor was 100 μ \\varepsilon . The biaxial sensor was applied to the side of a concrete cylinder, which was then placed under 0.6 mɛ of axial, compressive strain. Fractional shifts in impedance and wavelength, used to monitor axial and circumferential strain, were 3 × 10-2 and 4 × 10-5 respectively. The biaxial sensor’s strain resolution was approximately 10 μ \\varepsilon in both directions. Due to several design flaws, the uniaxial hybrid sensor was unable to accurately measure ambient temperature changes. The biaxial sensor, however, successfully monitored local temperature changes with 0.5 °C resolution.

  19. Geometric Phases for Photons in an Optical Fibre and Some Related Predictions

    Institute of Scientific and Technical Information of China (English)

    高孝纯

    2002-01-01

    We propose a quantum electrodynamic model for the description of the time evolution of the quantum states of the photons in an optical fibre. By means of this model, we are able to make three interesting predicticons related to the geometric phases for photons.

  20. Wide-Band Optical Fibre System for Investigation of MEMS and NEMS Deflection

    Directory of Open Access Journals (Sweden)

    Orłowska Karolina

    2014-08-01

    Full Text Available In this work the construction of experimental setup for MEMS/NEMS deflection measurements is presented. The system is based on intensity fibre optic detector for linear displacement sensing. Furthermore the electronic devices: current source for driving the light source and photodetector with wide-band preamplifier are presented.

  1. 3-D printed sensing patches with embedded polymer optical fibre Bragg gratings

    DEFF Research Database (Denmark)

    Zubel, Michal G.; Sugden, Kate; Saez-Rodriguez, D.;

    2016-01-01

    The first demonstration of a polymer optical fibre Bragg grating (POFBG) embedded in a 3-D printed structure is reported. Its cyclic strain performance and temperature characteristics are examined and discussed. The sensing patch has a repeatable strain sensitivity of 0.38 pm/mu epsilon. Its temp...

  2. Measuring the Dispersion Curve of a PMMA-Fibre Optic Cable Using a Dye Laser

    Science.gov (United States)

    Zorba, Serkan; Farah, Constantine; Pant, Ravi

    2010-01-01

    An advanced undergraduate laboratory experiment is outlined which uses a dye laser to map out the chromatic dispersion curve of a polymethyl methacrylate (PMMA) optical fibre. Seven different wavelengths across the visible spectrum are employed using five different dyes. The light pulse is split into two pulses, one to a nearby photodetector and…

  3. Extending the area of investigation of fine versus coarse quartz optical ages from the Lower Danube to the Carpathian Basin

    DEFF Research Database (Denmark)

    Timar-Gabor, Alida; Constantin, Daniela; Marković, S.B.;

    2015-01-01

    Despite the general satisfactory performance of quartz in the single aliquot regeneration protocol (SAR), previous optically stimulated luminescence (OSL) dating studies of key loess sections in Romania, Lower Danube region, revealed a disturbing disagreement among the ages obtained on fine (4e11...

  4. Optical fibre probes in the measurement of scattered light: Application for sensing turbidity

    Indian Academy of Sciences (India)

    M R Sheno

    2014-01-01

    Optical fibre probes or optrodes often form the heart of multimode fibre-based measurements and sensors. An optrode usually comprises a bundle of multimode fibres, out of which one or more fibres are used for irradiating the sample, and the remaining fibres are used to collect the light reflected/scattered/fluoresced from the sample containing the measurand(s). The so-collected light carries the characteristic signature of the measurand. Here we present our work on the design and realization of optrodes for the measurement of scattered light from liquid samples. Optical properties of a solution are usually characterized by the parameters absorption coefficient $_a$, scattering coefficient $_s$, and anisotropy factor . We have developed a simple method to determine $_a$, $_s$, and , of a turbid medium, and a Monte–Carlo model was used to simulate the light scattering from the turbid medium. As an application, we describe the development of a turbidity sensor that has been designed and realized by employing an optrode in conjunction with a concave mirror. The estimation of turbidity is done on the basis of total interaction, by considering scattering and absorption of light from the sample solution. Details of the experiments and results are presented here.

  5. Role of the interface between distributed fibre optic strain sensor and soil in ground deformation measurement

    Science.gov (United States)

    Zhang, Cheng-Cheng; Zhu, Hong-Hu; Shi, Bin

    2016-11-01

    Recently the distributed fibre optic strain sensing (DFOSS) technique has been applied to monitor deformations of various earth structures. However, the reliability of soil deformation measurements remains unclear. Here we present an integrated DFOSS- and photogrammetry-based test study on the deformation behaviour of a soil foundation model to highlight the role of strain sensing fibre–soil interface in DFOSS-based geotechnical monitoring. Then we investigate how the fibre–soil interfacial behaviour is influenced by environmental changes, and how the strain distribution along the fibre evolves during progressive interface failure. We observe that the fibre–soil interfacial bond is tightened and the measurement range of the fibre is extended under high densities or low water contents of soil. The plastic zone gradually occupies the whole fibre length when the soil deformation accumulates. Consequently, we derive a theoretical model to simulate the fibre–soil interfacial behaviour throughout the progressive failure process, which accords well with the experimental results. On this basis, we further propose that the reliability of measured strain can be determined by estimating the stress state of the fibre–soil interface. These findings may have important implications for interpreting and evaluating fibre optic strain measurements, and implementing reliable DFOSS-based geotechnical instrumentation.

  6. Fabrication of Pure Silica Core Multimode Ultraviolet Optical Fibre Probes by Tube Etching

    Institute of Scientific and Technical Information of China (English)

    HUO Xin; PAN Shi; WU Shi-Fa

    2007-01-01

    As a light wave-guide component for transmitting ultraviolet (UV) laser pulses, pure silica core UV fibre probes have attracted a great deal of attention in the near-field optical data storage and bio-medical studies. We fabricate UV fibre probes with tips in dimension of about 2-5μm and taper angle 16° by the tube etching method, using 40% HF acid as etching solution and xylene as overlayer. Probes produced have curvy configuration with smooth surface. The yield of fine probes is rather high and etching operation greatly simplified. With higher damage threshold, pure silica core multimode UV fibre probes can be coupled into more laser power. In addition, using UV light reduces the cutoff wavelength of the fibre probes, which is in favour of increasing the transmission efficiency of the probe. Furthermore, the larger tip dimension helps to enhance the light throughput either. The advances of fabrication technique of UV optical fibre probe may further support the studies of UV light data storage, pulsed laser biosurgery and UV photolithography.

  7. Polarization dependent dispersion and its impact on optical parametric process in high nonlinear microstructure fibre

    Institute of Scientific and Technical Information of China (English)

    Xiao Li; Zhang Wei; Huang Yi-Dong; Peng Jiang-De

    2008-01-01

    High nonlinear microstructure fibre (HNMF) is preferred in nonlinear fibre optics, especially in the applications of optical parametric effects, due to its high optical nonlinear coefficient. However, polarization dependent dispersion will impact the nonlinear optical parametric process in HNMFs. In this paper, modulation instability (MI) method is used to measure the polarization dependent dispersion of a piece of commercial HNMF, including the group velocity dispersion, the dispersion slope, the fourth-order dispersion and group birefringence. It also experimentally demonstrates the impact of the polarization dependent dispersion on the continuous wave supercontinuum (SC) generation. On one axis MI sidebands with symmetric frequency dctunings are generated, while on the other axis with larger MI frequency detuning, SC is generated by soliton self-frequency shift.

  8. A Lower Bound on the per Soliton Capacity of the Nonlinear Optical Fibre Channel

    CERN Document Server

    Shevchenko, Nikita A; Derevyanko, Stanislav A; Alvarado, Alex; Bayvel, Polina; Turitsyn, Sergei K

    2015-01-01

    A closed-form expression for a lower bound on the per soliton capacity of the nonlinear optical fibre channel in the presence of (optical) amplifier spontaneous emission (ASE) noise is derived. This bound is based on a non-Gaussian conditional probability density function for the soliton amplitude jitter induced by the ASE noise and is proven to grow logarithmically as the signal-to-noise ratio increases.

  9. Second-Harmonic Generation in Optical Fibres Induced by a Cross-Phase Modulation Effect

    Institute of Scientific and Technical Information of China (English)

    CUI Wei-Na; HUANG Guo-Xiang

    2005-01-01

    @@ When two optical pulses copropagate inside a single-modefibre, intensity-dependent refractive index couples the pulses through a cross-phase modulation (XPM). We show that a second-harmonic generation (SHG) on a continuous-wave background is possible in the optical fibre induced by the XPM effect. By means of a multiscale method the nonlinearly coupled envelope equations for the SHG are derived and their explicit solutions are provided and discussed.

  10. A method to remove residual signals in fibre optic luminescence dosimeters.

    Science.gov (United States)

    Lee, J J; Liu, P Z Y; McKenzie, D R; Suchowerska, N

    2013-03-07

    Whenever a fibre optic is used to convey a light signal through a radiation field, it is likely that an unwanted background signal will arise from Cerenkov or fluorescent light which will contaminate the signal. In luminescence dosimetry of high energy beams, when a fibre optic is used to convey the signal from the radiation field to the detector, Cerenkov light is the dominant contributor to the background signal and must be corrected for. In this work, a novel method is demonstrated to separate the signal from the unwanted background. A remotely operated shutter is used to block the signal, allowing the residual background in the fibre optic to be quantified. This background is subtracted from the total measurement acquired in a subsequent irradiation, enabling the luminescence signal to be extracted. Two types of shutter mechanism are considered: an electro-mechanical device to intercept the light path and an LCD device to block the light by cross-polarization. Both shutters were characterized and incorporated into a fibre optic dosimetry system used to measure the radiation dose produced by external beam radiation linear accelerators. The dosimeter using each of the shutters in turn was exposed to a 6 MV photon beam to determine their performance, including the measurement of field size dependent output factors. The mechanical shutter determined the output factors to within 0.29% of those measured with an ionization chamber, whereas the LCD shutter gave results that deviated by up to 2.4%. The switching precision of both shutters was good with standard deviations of less than 0.25% and both were able to completely block the light signal when closed. The use of shutters could therefore be applied to any fibre optic based system to quantify and remove a reproducible background arising from any source including ambient, fluorescent and Cerenkov light.

  11. Thermoluminescence Responses of Photon and Electron Irradiated Ge- and Al-Doped SiO2 Optical Fibres

    Institute of Scientific and Technical Information of China (English)

    H. Wagiran; I. Hossain; D. Bradley; A. N. H. Yaakob; T. Ramli

    2012-01-01

    We carry out a comparison of the thermoluminescence (TL) response of photon and electron irradiated Ge- and Al-doped SiO2 optical fibres,as well as cross-comparison with that of TLD-100.Irradiation is made with 6 MeV electrons and 6 MV photons,for doses ranging from 0.2 Gy to 4.0Gy.The commercially available Al- and Gedoped optical fibres produce a linear dose-TL response.The TL yield for both of the doped fibres and also for TLD-100 is greater for electron irradiation than for photon irradiation.The TL yield of the Al-doped fibres is a small fraction of that of Ge-doped fibres (by a factor of 25),the Ge-doped fibres offering a response of 59%o of that of TLD-100.%We carry out a comparison of the thermoluminescence (TL) response of photon and electron irradiated Ge- and Al-doped SiO2 optical fibres, as well as cross-comparison with that of TLD-100. Irradiation is made with 6 MeV electrons and 6MV photons, for doses ranging from 0.2 Gy to 4.0Gy. The commercially available Al- and Ge-doped optical fibres produce a linear dose-TL response. The TL yield for both of the doped fibres and also for TLD-100 is greater for electron irradiation than for photon irradiation. The TL yield of the Al-doped fibres is a small fraction of that of Ge-doped fibres (by a factor of 25), the Ge-doped fibres offering a response of 59% of that of TLD-100.

  12. High-Frequency RIN Transfer in Fibre Optic Parametric Amplifiers

    DEFF Research Database (Denmark)

    Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke; Kang, Ning

    2011-01-01

    ibre optic parametric amplifiers (FOPAs) are versatile devices for amplification at arbitrary wavelengths, as well as a wide range of optical signal processing applications, including switching, wavelength conversion, regeneration, pulse generation etc [1]. Transfer of intensity fluctuations from...

  13. Chemical detection in liquid media with a refractometric sensor based on a multimode optical fibre

    OpenAIRE

    V. Matejec; Jaffrezic-Renault, N.; Abdelghani, A.; S. Hleli; Cherif, K

    2002-01-01

    In this paper the physical basis for the design of an optical fibre sensor suited for aqueous medium and gas phase based on the excitation of an evanescent wave at the core/cladding interface is developed. The detection based on the refractive index changes (between 1.41 and 1.45) of the infinite dielectric medium which can be an electrolyte or a sol-gel polymer deposited on the uncladed part of the fibre. Refractive indices of absorbent and volatile compounds such as fuel and unleaded gas we...

  14. Many-body quantum dynamics of polarisation squeezing in optical fibre

    CERN Document Server

    Corney, J F; Heersink, J; Josse, V; Leuchs, G; Andersen, U L

    2006-01-01

    We report new experiments that test quantum dynamical predictions of polarization squeezing for ultrashort photonic pulses in a birefringent fibre, including all relevant dissipative effects. This exponentially complex many-body problem is solved by means of a stochastic phase-space method. The squeezing is calculated and compared to experimental data, resulting in excellent quantitative agreement. From the simulations, we identify the physical limits to quantum noise reduction in optical fibres. The research represents a significant experimental test of first-principles time-domain quantum dynamics in a one-dimensional interacting Bose gas coupled to dissipative reservoirs.

  15. Glucose optical fibre sensor based on a luminescent molecularly imprinted polymer

    Science.gov (United States)

    Elosua, C.; Wren, S. P.; Sun, T.; Arregui, F. J.; Grattan, Kenneth T. V.

    2015-09-01

    An optrode able to detect glucose dissolved in water has been implemented. The device is based on the luminescence emission of a Molecularly Imprinted Polymer synthesized specifically for glucose detection, therefore its intensity changes in presence of glucose. This sensing material is attached onto a cleaved ended polymer-clad optical fibre and it is excited by light via 1x2 fibre coupler. The reflected fluorescence signal increases when it is immersed into glucose solutions and recovers to the baseline when it is dipped in ultrapure water. This reversible behaviour indicates the measurement repeatability of using such a glucose sensor.

  16. Surface plasmon resonance based fibre optic chemical sensor for the detection of cocaine

    Science.gov (United States)

    Nguyen, T. Hien; Sun, Tong; Grattan, Kenneth T. V.

    2016-05-01

    A surface plasmon based fibre-optic chemical sensor for the detection of cocaine has been developed using a molecularly imprinted polymer (MIP) film with embedded gold nanoparticles as the recognition element. The MIP was formed on the layer of gold thin film which was deposited on the surface of a fibre core. The sensing was based on swelling of the MIP film induced by analyte binding that shifted the resonance spectrum toward a shorter wavelength. The sensor exhibited a response to cocaine in the concentration range of 0 - 400 μM in aqueous acetonitrile mixtures. Selectivity for cocaine over other drugs has also been demonstrated.

  17. Influence of a thin metal layer on a beam propagation in a biconical optical fibre taper

    Science.gov (United States)

    Stasiewicz, K. A.; Moś, J. E.

    2016-12-01

    The paper presents results of a simulation of the plasmon effect achieved between a thin precious metal layer and a biconical optical fibre taper, manufactured on a standard single mode fibre. Gold, silver and titanium were used as a metal which fulfilled a cladding function for a small diameter structure. For simulation Mode Solution software was used on which modal and frequency analyses of a wavelength were provided in the range of 800-1700 nm. A displacement of a plasmon pick in dependence of thickness of a deposited precious layer for the highest plasmon effects was observed.

  18. Theoretical Design of Single-Polarization Single- Mode Microstructured Polymer Optical Fibres

    Institute of Scientific and Technical Information of China (English)

    REN Li-Yong; WANG Han-Yi; ZHANG Ya-Ni; YAO Bao-Li; ZHAO Wei

    2007-01-01

    Using the full-vector plane-wave expansion method, a kind of PMMA-based polarization-maintaining microstructured optical fibre (PM-mPOF) is theoretically studied. Dependence of the cutoff wavelengths of the two orthogonal polarization states (polarized along the two principal axes of PM-mPOF) on the structure parameters of the fibre is investigated in detail. A single-polarization single-mode (SPSM) PM-mPOF working in the visible region is designed and optimized with the result of the maximum SPSM bandwidth of 140 nm.

  19. Optically stimulated luminescence sensitivity changes in quartz due to repeated use in single aliquot readout: Experiments and computer simulations

    DEFF Research Database (Denmark)

    McKeever, S.W.S.; Bøtter-Jensen, L.; Agersnap Larsen, N.

    1996-01-01

    As part of a study to examine sensitivity changes in single aliquot techniques using optically stimulated luminescence (OSL) a series of experiments has been conducted with single aliquots of natural quartz, and the data compared with the results of computer simulations of the type of processes...... believed to be occurring. The computer model used includes both shallow and deep ('hard-to-bleach') traps, OSL ('easy-to-bleach') traps, and radiative and non-radiative recombination centres. The model has previously been used successfully to account for sensitivity changes in quartz due to thermal...... trap and deep trap effects....

  20. Combined optical second harmonic generation/quartz crystal microbalance study of underpotential deposition processes: copper electrodeposition on polycrystalline gold.

    Science.gov (United States)

    Lakkaraju, S; Bennahmias, M J; Borges, G L; Gordon Ii, J G; Lazaga, M; Stone, B M; Ashley, K

    1990-11-20

    Optical second harmonic generation and quartz crystal microbalance techniques are used as in situ probes of copper underpotential deposition on polycrystalline gold surfaces in sulfuric acid electrolyte. The second harmonic signal from a polished bulk gold substrate is observed to decrease by >60% as a result of copper underpotential deposition on gold. Also, the mass of an underpotentially deposited copper adlayer is monitored in situ by an oscillating quartz crystal microbalance, yielding an estimated coverage of ~8.0 x 10(-10) mol cm(-2) and an electrosorption valency of 1.5 for a copper adlayer on the surface of vapor-deposited polycrystalline gold.

  1. Polarization contrast in reflection near-field optical microscopy with uncoated fibre tips

    DEFF Research Database (Denmark)

    Bozhevolnyi, Sergey I.; Langbein, Wolfgang; Hvam, Jørn Märcher

    1999-01-01

    Using cross-hatched, patterned semiconductor surfaces and round 20-nm-thick gold pads on semiconductor wafers, we investigate the imaging characteristics of a reflection near-field optical microscope with an uncoated fibre tip for different polarization configurations and light wavelengths....... Is is shown that cross-polarized detection allows one to effectively suppress far-field components in the detected signal and to realise imaging of optical contrast on the sub-wavelength scale. The sensitivity window of our microscope, i.e. the scale on which near-field optical images represent mainly optical...

  2. Radiation Damage of Quartz Fibers

    CERN Document Server

    Hagopian, V

    1999-01-01

    Quartz fibers are used in high energy physics experiments as the active medium in high radiation area calorimetry. Quartz fibers are also used in the transmission of optical signals. Even though quartz does not damage by moderate amounts of irradiation, the clad of the fibers and the protective coating ( buffer) do damage reducing light transmission. Various types of quartz fibers have been irradiated and measured for light transmission. The most radiation hard quartz fibers are those with quartz clad and aluminum buffer.

  3. High stress monitoring of prestressing tendons in nuclear concrete vessels using fibre-optic sensors

    Energy Technology Data Exchange (ETDEWEB)

    Perry, M., E-mail: marcus.perry@strath.ac.uk [Institute for Energy and Environment, University of Strathclyde, 204 George Street, Glasgow G1 1XW (United Kingdom); Yan, Z.; Sun, Z.; Zhang, L. [Aston Institute of Photonic Technologies, Aston University, Birmingham B4 7ET (United Kingdom); Niewczas, P. [Institute for Energy and Environment, University of Strathclyde, 204 George Street, Glasgow G1 1XW (United Kingdom); Johnston, M. [Civil Design Group, EDF Energy, Nuclear Generation, East Kilbride G74 5PG (United Kingdom)

    2014-03-15

    Highlights: • We weld radiation-resistant optical fibre strain sensors to steel prestressing tendons. • We prove the sensors can survive 1300 MPa stress (80% of steel's tensile strength). • Mechanical relaxation of sensors is characterised under 1300 MPa stress over 10 h. • Strain transfer between tendon and sensor remains at 69% after relaxation. • Sensors can withstand and measure deflection of tendon around a 4.5 m bend radius. - Abstract: Maintaining the structural health of prestressed concrete nuclear containments is a key element in ensuring nuclear reactors are capable of meeting their safety requirements. This paper discusses the attachment, fabrication and characterisation of optical fibre strain sensors suitable for the prestress monitoring of irradiated steel prestressing tendons. The all-metal fabrication and welding process allowed the instrumented strand to simultaneously monitor and apply stresses up to 1300 MPa (80% of steel's ultimate tensile strength). There were no adverse effects to the strand's mechanical properties or integrity. After sensor relaxation through cyclic stress treatment, strain transfer between the optical fibre sensors and the strand remained at 69%. The fibre strain sensors could also withstand the non-axial forces induced as the strand was deflected around a 4.5 m bend radius. Further development of this technology has the potential to augment current prestress monitoring practices, allowing distributed measurements of short- and long-term prestress losses in nuclear prestressed-concrete vessels.

  4. Fabry-Perot micro-structured polymer optical fibre sensors for opto-acoustic endoscopy

    DEFF Research Database (Denmark)

    Broadway, Christian; Gallego, Daniel; Woyessa, Getinet

    2015-01-01

    Opto-Acoustic Endoscopy (OAE) requires sensors with a high sensitivity and small physical dimensions in order to facilitate integration into an endoscope of less than 1mm in diameter. We present fibre Bragg grating (FBG) and Fabry- Perot intrinsic fibre sensors for ultrasound detection. We present...... a structure profile characterisation setup to analyse tune the fibre sensors in preparation for ultrasonic detection. We evaluate the suitability of the different structures and grating parameters for ultrasonic sensing. By analysing the prepared gratings, we enable the optimisation of the profile...... and a simplification of the detection regime for an optimal interferometric OAE configuration. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only....

  5. Fibre-optic sensors for partial discharge-generated ultrasound in elastomeric high-voltage insulation materials

    Science.gov (United States)

    Rohwetter, P.; Habel, W.

    2013-05-01

    Recent progress in the development of ultrasonic fibre-optic sensors for detecting acoustic emission from partial discharge in elastomeric insulations is presented. These sensors are an important part of a proposed comprehensive scheme for the fibre-optic monitoring of cable accessories. After specifying the underlying design goals the improved fibre-optic sensor design is outlined. It is experimentally shown that it offers about ten-fold improvement over a previously investigated resonant cantilever-type design in terms of detection limit, making it competitive with conventional piezoelectric transducers, however with the added compatibility with strong electrical fields and electromagnetically noisy environments.

  6. Investigation of bending loss in a single-mode optical fibre

    Indian Academy of Sciences (India)

    A Zendehnam; M Mirzaei; A Farashiani; L Horabadi Farahani

    2010-04-01

    Loss of optical power in a single-mode optical fibre due to bending has been investigated for a wavelength of 1550 nm. In this experiment, the effects of bending radius (4–15 mm, with steps of 1 mm), and wrapping turns (up to 40 turns) on loss have been studied. Twisting the optical fibre and its influence on power loss also have been investigated. Variations of bending loss with these two parameters have been measured, loss with number of turns and radius of curvature have been measured, and with the help of computer curve fitting method, semi-empirical relationships between bending loss and these two parameters have been found, which show good agreement with the obtained experimental results.

  7. Surface topography of machined fibre reinforced plastics obtained by stylus instruments and optical profilometers

    DEFF Research Database (Denmark)

    Eriksen, Else; Hansen, Hans Nørgaard

    1998-01-01

    introduced. They use another working principle to obtain the same parameters, but the settings of most of the measuring variables are not standardized. The present study has investigated aspects that have to be taken into account when the roughness of short fibre reinforced thermoplastics is measured...... identical values, whereas significantly higher roughnesses were measured with one of the two optical instruments. The optical instruments were identical but with different settings of the control parameters, which resulted in large deviations between the values measured. Some of the differences between...... by stylus instruments and by optical profilometers. The measurements were performed on machined surfaces with three distinct different roughness levels. The materials were two thermoplastics, polyoxymethylene and polypropylene, reinforced with short glass fibres. The two stylus instruments gave almost...

  8. Real-time measurements of spontaneous breathers and rogue wave events in optical fibre modulation instability

    Science.gov (United States)

    Närhi, Mikko; Wetzel, Benjamin; Billet, Cyril; Toenger, Shanti; Sylvestre, Thibaut; Merolla, Jean-Marc; Morandotti, Roberto; Dias, Frederic; Genty, Goëry; Dudley, John M.

    2016-12-01

    Modulation instability is a fundamental process of nonlinear science, leading to the unstable breakup of a constant amplitude solution of a physical system. There has been particular interest in studying modulation instability in the cubic nonlinear Schrödinger equation, a generic model for a host of nonlinear systems including superfluids, fibre optics, plasmas and Bose-Einstein condensates. Modulation instability is also a significant area of study in the context of understanding the emergence of high amplitude events that satisfy rogue wave statistical criteria. Here, exploiting advances in ultrafast optical metrology, we perform real-time measurements in an optical fibre system of the unstable breakup of a continuous wave field, simultaneously characterizing emergent modulation instability breather pulses and their associated statistics. Our results allow quantitative comparison between experiment, modelling and theory, and are expected to open new perspectives on studies of instability dynamics in physics.

  9. Quantum storage of entangled telecom-wavelength photons in an erbium-doped optical fibre

    CERN Document Server

    Saglamyurek, Erhan; Verma, Varun B; Shaw, Matthew D; Marsili, Francesco; Nam, Sae Woo; Oblak, Daniel; Tittel, Wolfgang

    2014-01-01

    The realization of a future quantum Internet requires processing and storing quantum information at local nodes, and interconnecting distant nodes using free-space and fibre-optic links. Quantum memories for light are key elements of such quantum networks. However, to date, neither an atomic quantum memory for non-classical states of light operating at a wavelength compatible with standard telecom fibre infrastructure, nor a fibre-based implementation of a quantum memory has been reported. Here we demonstrate the storage and faithful recall of the state of a 1532 nm wavelength photon, entangled with a 795 nm photon, in an ensemble of cryogenically cooled erbium ions doped into a 20 meter-long silicate fibre using a photon-echo quantum memory protocol. Despite its currently limited efficiency and storage time, our broadband light-matter interface brings fibre-based quantum networks one step closer to reality. Furthermore, it facilitates novel tests of light-matter interaction and collective atomic effects in u...

  10. Suppression of Brillouin scattering in fibre-optical parametric amplifier by applying temperature control and phase modulation

    DEFF Research Database (Denmark)

    Lorenzen, Michael Rodas; Noordegraaf, Danny; Nielsen, Carsten Vandel

    2009-01-01

    An increased gain in a fibre-optical parametric amplifier through suppression of stimulated Brillouin scattering is demonstrated by applying a temperature distribution along the fibre for a fixed phase modulation of the pump. The temperature distribution slightly impacts the gain spectrum....

  11. Thermoluminescent sensitivity of single clad neodymium doped SiO2 optical fibres measured with 6 MeV photons

    Science.gov (United States)

    Saeed, M. A.; Hossain, I.; Hida, N.; Wagiran, H.

    2013-10-01

    This study investigates the thermoluminescent sensitivity of neodymium doped SiO2 optical fibre with various dose ranges from 0.5 Gy to 4.0 Gy by 6 MeV photon irradiations. The TL responses of the neodymium doped silica fibres are compared with available TLD-100 dosimeter in order to determine the suitability as a TL material. We found that the TLD-100 and neodymium doped silica fibre have a significant linear signal to dose relationship. Neodymium doped fibres sensitivity is approximately 11% of TLD-100.

  12. A simple and inexpensive optical power monitor for two visible wavelength WDM channels in plastic optical fibre links

    Science.gov (United States)

    Freitas, Taiane A. M. G.; Marcondes, Claudia B.; Ribeiro, Ricardo M.

    2016-12-01

    This paper shows for the first time, to the best of our knowledge, the design of a simple, non-invasive, bidirectional and inexpensive optical power monitor (OPMo) for WDM over PMMA-based polymer optical fibre (POF) links transmitting 470 nm and 650 nm wavelengths light carriers. Low-cost cellophane plastic optical filters were used for each WDM channel aiming to demonstrate the OPMo operational principle. The OPMo is non-invasive because it does not tap any guided light from the fibre core; rather, it collects and detects the spontaneous side-scattered light. A sensitivity of  -32 dBm and dynamic range of 38.8 dB were measured. A crosstalk rejection better than 25 dB was achieved when both light carriers are of the same power.

  13. Optical fibre Fabry-Perot relative humidity sensor based on HCPCF and chitosan film

    Science.gov (United States)

    Liu, Xiaohui; Jiang, Mingshun; Sui, Qingmei; Geng, Xiangyi

    2016-09-01

    An optical fibre Fabry-Perot interferometer (FPI) sensor for relative humidity (RH) measurement is proposed. The FPI is formed by splicing a short section of hollow-core photonic crystal fibre(HCPCF) to single mode fibre and covering a chitosan film at the end of HCPCF. The refractive index of chitosan and film thickness will change with ambient RH, leading to the change in the reflected interference spectrum of FPI. RH response of the FPI sensor is analysed theoretically and demonstrated experimentally. It shows nonlinear response to RH values from 35 to 95%RH. The interference fringe shifts to shorter wavelength as RH increases with a maximum sensitivity of 0.28 nm/%RH at high RH level. And the fringe contrast also decreases as RH increases with an available maximum sensitivity of 0.5 dB/%RH. The sensor shows good stability and fast response time less than 1 min. With its advantages of compact structure, good performance, simple and safe fabrication, the proposed optical fibre FPI sensor has great potential for RH sensing.

  14. CW-OSL measurement protocols using optical fibre Al2O3:C dosemeters

    DEFF Research Database (Denmark)

    Edmund, J.M.; Andersen, C.E.; Marckmann, C.J.

    2006-01-01

    A new system for in vivo dosimetry during radiotherapy has been introduced. Luminescence signals from a small crystal of carbon-doped aluminium oxide (Al2O3:C) are transmitted through an optical fibre cable to an instrument that contains optical filters, a photomultiplier tube and a green (532 nm......) laser. The prime output is continuous wave optically stimulated luminescence (CW-OSL) used for the measurement of the integrated dose. We demonstrate a measurement protocol with high reproducibility and improved linearity, which is suitable for clinical dosimetry. A crystal-specific minimum pre...

  15. A model of the mammalian optic nerve fibre based on experimental data.

    Science.gov (United States)

    Oozeer, M; Veraart, C; Legat, V; Delbeke, J

    2006-08-01

    Several experimental data about membrane dynamics and pharmacological sensitivities of optic nerve axons have been published. The present work summarizes these data and computer simulations have been used to develop a model of the mammalian optic nerve fibre. The ionic currents description were derived from existing membrane models and particularly from a model of the somatic retinal ganglion cell (RGC) impulse generation. However, original equations had to be modified to match experimental data, which suggests that in RGCs, axonal and somatic ion channel expression are different. The new model is consistent with recent experimental results about optic nerve axonal excitability.

  16. A hybrid humidity sensor using optical waveguides on a quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Shinbo, Kazunari, E-mail: kshinbo@eng.niigata-u.ac.j [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Otuki, Shunya; Kanbayashi, Yuichi [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Ohdaira, Yasuo [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Baba, Akira [Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Kato, Keizo; Kaneko, Futao [Graduate School of Science and Technology, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Center for Transdisciplinary Research, Niigata University, 2-8050 Ikarashi, Nishi-ku, Niigata City, Niigata 950-2181 (Japan); Miyadera, Nobuo [Hitachi Chemical Co., Ltd., 48 Wadai, Tsukuba City, Ibaraki 300-4247 (Japan)

    2009-11-30

    In this study, slab and ridge optical waveguides (OWGs) made of fluorinated polyimides were deposited on a quartz crystal microbalance (QCM), and hybrid sensors using OWG spectroscopy and the QCM technique were prepared. Polyvinyl alcohol (PVA) film with CoCl{sub 2} was deposited on the OWGs, and the characteristics of humidity sensing were investigated. A prism coupler was used to enter a He-Ne laser beam ({lambda} = 632.8 nm) to the slab OWG. The output light intensity markedly changed due to chromism of the CoCl{sub 2} as a result of humidity sorption, and this change was dependent on the incident angle of the laser beam to the slab OWG. During the measurement of output light, the QCM frequency was simultaneously monitored. The humidity dependence of the sensor with the slab OWG was also investigated in the range from 15 to 85%. For the sensor with the ridge OWG, white light was entered by butt-coupling, and the characteristics of humidity sensing were investigated by observing the output light spectrum and the QCM frequency.

  17. Design of a Sensor Based on Plastic Optical Fibre (POF) to Measure Fluid Flow and Turbidity.

    Science.gov (United States)

    Aiestaran, Pedro; Arrue, Jon; Zubia, Joseba

    2009-01-01

    Although many optical fibre applications are based on their capacity to transmit optical signals with low losses, it can also be desirable for the optical fibre to be strongly affected by a certain physical parameter in the environment. In this way, it can be used as a sensor for this parameter. There are many strong arguments for the use of POFs as sensors. In addition to being easy to handle and low cost, they demonstrate advantages common to all multimode optical fibres. These specifically include flexibility, small size, good electromagnetic compatibility behaviour, and in general, the possibility of measuring any phenomenon without physically interacting with it. In this paper, a sensor based on POF is designed and analysed with the aim of measuring the volume and turbidity of a low viscosity fluid, in this case water, as it passes through a pipe. A comparative study with a commercial sensor is provided to validate the proven flow measurement. Likewise, turbidity is measured using different colour dyes. Finally, this paper will present the most significant results and conclusions from all the tests which are carried out.

  18. Design of a Sensor Based on Plastic Optical Fibre (POF to Measure Fluid Flow and Turbidity

    Directory of Open Access Journals (Sweden)

    Joseba Zubia

    2009-05-01

    Full Text Available Although many optical fibre applications are based on their capacity to transmit optical signals with low losses, it can also be desirable for the optical fibre to be strongly affected by a certain physical parameter in the environment. In this way, it can be used as a sensor for this parameter. There are many strong arguments for the use of POFs as sensors. In addition to being easy to handle and low cost, they demonstrate advantages common to all multimode optical fibres. These specifically include flexibility, small size, good electromagnetic compatibility behaviour, and in general, the possibility of measuring any phenomenon without physically interacting with it. In this paper, a sensor based on POF is designed and analysed with the aim of measuring the volume and turbidity of a low viscosity fluid, in this case water, as it passes through a pipe. A comparative study with a commercial sensor is provided to validate the proven flow measurement. Likewise, turbidity is measured using different colour dyes. Finally, this paper will present the most significant results and conclusions from all the tests which are carried out.

  19. Polarization Maintaining Fibre Loop Mirror for NRZ-to-PRZ Conversion in All-Optical Clock Recovery

    Institute of Scientific and Technical Information of China (English)

    XU Fan; ZHANG Xin-Liang; LIU Hai-Rong; LIU De-Ming; HUANG De-Xiu

    2006-01-01

    @@ We propose a novel configuration for clock extraction by converting the NRZ data into the PRZ data and by employing a polarization-maintaining fibre loop mirror (PMFLM) which is usually used as an optical comb filter.

  20. Effects of {gamma} and neutron irradiation on the optical absorption of pure silica core single-mode optical fibres from Nufern

    Energy Technology Data Exchange (ETDEWEB)

    Calderon, A. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Martinez-Rivero, C. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Matorras, F. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Rodrigo, T. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Sobron, M. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Vila, I. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Virto, A.L. [Instituto de Fisica de Cantabria, CSIC-University of Cantabria, Santander (Spain); Alberdi, J. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Arce, P. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Barcala, J.M. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Calvo, E. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Ferrando, A. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain)]. E-mail: Antonio.Ferrando@ciemat.es; Josa, M.I. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Luque, J.M. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Molinero, A. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Navarrete, J. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Oller, J.C. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Valdivieso, P. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Yuste, C. [CIEMAT, Particle Physics, Avda. Complutense 22, 28040, Madrid (Spain); Fenyvesi, A. [Institute of Nuclear Research, ATOMKI, Debrecen (Hungary); Molnar, J. [Institute of Nuclear Research, ATOMKI, Debrecen (Hungary)

    2006-09-15

    A measurement of the optical absorption, induced by photon irradiation up to a dose of 0.9 MGy, in Nufern silica core single-mode optical fibres is presented. In addition, the fibres were irradiated with neutrons, up to a total fluence of 2x10{sup 14} cm{sup -2} and the induced optical absorption was evaluated for four different wavelengths: 630, 670, 681 and 785 nm.

  1. New radiation-induced effects in optical fibres feasible for dosimetry; Nouveaux effets induits par rayonnement dans des fibres optiques dediees a la dosimetrie

    Energy Technology Data Exchange (ETDEWEB)

    Tomashuk, A.L.; Golant, K.M.; Dianov, E.M.; Nikolin, I.V. [Fibre Optics Research Centre (FORC), Moscow (Russian Federation); Zakharkin, I.I.; Stepanov, V.A. [Institute of Physics and Power Engineering, SSC RF, Obninsk (Russian Federation)

    1999-07-01

    Three new radiation-induced effects in silica optical fibres suitable for dosimetry are proposed: 1) in fibres with a high-OH cladding and a low-OH core, ionizing radiation disrupts the O-H bonds to let hydrogen diffuse into the core. This results in an increase in the OH-group absorption band amplitude, 2) the polymers used to coat optical fibres consist of hydrogen to the extent of about 50 %. Energetic neutrons produce recoil protons in the fibre coating, which can ''stick'' in the core, turn into hydrogen, and enter the glass network in the form of OH-group, and 3) in N-doped silica fibres irradiated with thermal neutrons, the following reaction {sub 7}N{sup 14}({sub 0}n{sup 1},{sub 1}p{sup 1}){sub 6}C{sup 14} occurs and produces protons with energy 620 keV. With this energy, propagation length of protons in silica is 7 {mu}m which means that the escape of protons from a 50 {mu}m core is very weak. In fact all 3 effects lead to the irreversible increase in the OH-group absorption bands, which is proportional to the absorbed dose. With the help of these effects, temperature and dose-rate independent measurements of high doses become possible.

  2. Fibre Optic Readout of Microcantilever Arrays for Fast Microorganism Growth Detection

    Directory of Open Access Journals (Sweden)

    N. Maloney

    2012-01-01

    Full Text Available We present a fibre-optic-based device for the automated readout of microcantilever arrays for fast microorganism growth detection. We determined the ability of our device to track shifts in resonance frequency due to an increase in mass on the cantilever surface or changes in mechanical stiffness. The resonance frequency response of 7 μm thick agarose-functionalised cantilevers was tracked as humidity levels were varied revealing a mass responsivity of ~51±1 pg/Hz. The resonance response of microcantilevers coated with Aspergillus niger (A. niger spores was monitored for >48 h revealing a growth detection time of >4 h. The growth of mycelium along the cantilevers surface is seen to result in an increase in resonance frequency due to the reinforcement of the cantilever structure. The use of our fibre optic detection technique allows data to be recorded continuously and faster than previously reported.

  3. Plastic optical fibre sensor for in-vivo radiation monitoring during brachytherapy

    Science.gov (United States)

    Woulfe, P.; Sullivan, F. J.; Lewis, E.; O'Keeffe, S.

    2015-09-01

    An optical fibre sensor is presented for applications in real-time in-vivo monitoring of the radiation dose a cancer patient receives during seed implantation in Brachytherapy. The sensor is based on radioluminescence whereby radiation sensitive scintillation material is embedded in the core of a 1mm plastic optical fibre. Three scintillation materials are investigated: thallium-doped caesium iodide (CsI:Tl), terbium-doped gadolinium oxysulphide (Gd2O2S:Tb) and europium-doped lanthanum oxysulphide (La2O2S:Eu). Terbium-doped gadolinium oxysulphide was identified as being the most suitable scintillator and further testing demonstrates its measureable response to different activities of Iodine-125, the radio-active source commonly used in Brachytherapy for treating prostate cancer.

  4. Multichannel optical-fibre heterodyne interferometer for ultrasound detection of partial discharges in power transformers

    Science.gov (United States)

    Posada, J. E.; Garcia-Souto, J. A.; Rubio-Serrano, J.

    2013-09-01

    A multichannel interferometric system is proposed for the ultrasonic detection of partial discharges using intrinsic optical fibre sensors that may be immersed in oil. It is based on a heterodyne scheme which drives at least four sensor heads in order to localize the source of the acoustic emissions. Proper design of the sensing head improves its sensitivity through magnification and reaches a compact encapsulated probe able to be installed within power transformers. The optoelectronic implementation and the experimental tests are presented to optimize the resolution (4 channels—4 mrad). In addition, the results of ultrasound measurements at 150 kHz with an optical fibre sensor immersed in water in an acoustic test bench are shown, in which a resolution better than 10 Pa was obtained. Finally, the set-up for three-phase power transformers is demonstrated and characterized to detect and locate the source of acoustic emissions.

  5. Enhanced Transmission Stability of Polarization Solitons in Birefringent Fibres with an Optical Phase Conjugator

    Institute of Scientific and Technical Information of China (English)

    陈伟成; 谢嘉宁; 路洪; 徐文成

    2003-01-01

    An optical phase conjugator is used to enhance transmission stability of polarization solitons in highly birefringent fibres. Two polarization solitons form a breather in fibres with low birefringence firstly and the optical phase conjugator is used to make the spectra of polarization solitons converse, which results in the fact that the polarization soliton along the fast axis is compressed due to the strengthened self-phase modulation effect. Two polarization solitons are compressed further due to the cross-phase modulation effect. The enhanced nonlinear effects make the central peak frequencies of two polarization solitons shift to the larger range in opposite directions so that they trap each other fully to suppress the effect of birefringence.

  6. Chemical detection in liquid media with a refractometric sensor based on a multimode optical fibre

    Directory of Open Access Journals (Sweden)

    V. Matejec

    2002-06-01

    Full Text Available In this paper the physical basis for the design of an optical fibre sensor suited for aqueous medium and gas phase based on the excitation of an evanescent wave at the core/cladding interface is developed. The detection based on the refractive index changes (between 1.41 and 1.45 of the infinite dielectric medium which can be an electrolyte or a sol-gel polymer deposited on the uncladed part of the fibre. Refractive indices of absorbent and volatile compounds such as fuel and unleaded gas were determined. Using a xerogel sensing layer as optical cladding, toluene detection in water was performed. The observed sensitivity is linear and the detection limit is 1% (in volume toluene in water.

  7. Direct optical activation of skeletal muscle fibres efficiently controls muscle contraction and attenuates denervation atrophy.

    Science.gov (United States)

    Magown, Philippe; Shettar, Basavaraj; Zhang, Ying; Rafuse, Victor F

    2015-10-13

    Neural prostheses can restore meaningful function to paralysed muscles by electrically stimulating innervating motor axons, but fail when muscles are completely denervated, as seen in amyotrophic lateral sclerosis, or after a peripheral nerve or spinal cord injury. Here we show that channelrhodopsin-2 is expressed within the sarcolemma and T-tubules of skeletal muscle fibres in transgenic mice. This expression pattern allows for optical control of muscle contraction with comparable forces to nerve stimulation. Force can be controlled by varying light pulse intensity, duration or frequency. Light-stimulated muscle fibres depolarize proportionally to light intensity and duration. Denervated triceps surae muscles transcutaneously stimulated optically on a daily basis for 10 days show a significant attenuation in atrophy resulting in significantly greater contractile forces compared with chronically denervated muscles. Together, this study shows that channelrhodopsin-2/H134R can be used to restore function to permanently denervated muscles and reduce pathophysiological changes associated with denervation pathologies.

  8. Temperature-Insensitive Chemical Sensor with Twin Bragg Gratings in an Optical Fibre

    Institute of Scientific and Technical Information of China (English)

    SANG Xin-Zhu; YU Chong-Xiu; YAN Bin-Bin; MA Jian-Xin; MENG Zhao-Fang; Mayteevarunyoo T.; LU Nai-Guang

    2006-01-01

    To reduce temperature sensitivity of the fibre Bragg grating (FBG) chemical sensor, a simple method is proposed by measuring the peak wavelength difference between an etched FBG and an un-etched one in an optical fibre.Thermal characteristics and chemical sensitivity of the sensor are experimentally investigated. The experimental results indicate that the etched FBG and the rest one have almost the same thermal response, and concentration changes of the surrounding chemical solutions can be detected by measuring the peak wavelength difference between them. The sensor has been used to measure the concentrations of propylene glycol solutions and sugar solutions, and it could detect 0.7% and 0.45% concentration changes for them with an optical spectrum analyser in resolution of 10pm.

  9. Experimental Investigation on a Fibre-Optic Hydrophone with a Cylindrical Helmholtz Resonator

    Institute of Scientific and Technical Information of China (English)

    WANG Ze-Feng; HUNG Yong-Ming; MENG Zhou; NI Ming

    2008-01-01

    A novel mechanical anti-aliasing filtering fibre-optic hydrophone with a cylindrical Helmholtz resonator is constructed and tested.The experimental results show that the hydrophone has a function of low-pass filtering.The low frequency acoustic sensitivity is about -160 dB (1 rad/μPa),and the response curve has a resonance determined by the Helmholtz resonator.Theoretical and experimental results both show that the resonant frequency moves towards high frequency with the increasing orifice diameters.The sensitivity attenuation of high frequency is larger than 10 dB.This new fibre-optic hydrophone is a prototype device for a c/ass of sensors used to eliminate the aliasing in future sonar systems.

  10. 3D printed sensing patches with embedded polymer optical fibre Bragg gratings

    Science.gov (United States)

    Zubel, Michal G.; Sugden, Kate; Saez-Rodriguez, D.; Nielsen, K.; Bang, O.

    2016-05-01

    The first demonstration of a polymer optical fibre Bragg grating (POFBG) embedded in a 3-D printed structure is reported. Its cyclic strain performance and temperature characteristics are examined and discussed. The sensing patch has a repeatable strain sensitivity of 0.38 pm/μepsilon. Its temperature behaviour is unstable, with temperature sensitivity values varying between 30-40 pm/°C.

  11. A Novel Approach to the Sensing of Liquid Density Using a Plastic Optical Fibre Cantilever Beam

    Science.gov (United States)

    Kulkarni, Atul; Kim, Youngjin; Kim, Taesung

    2009-01-01

    This article reports for the first time the use of a plastic optical fibre (POF) cantilever beam to measure the density of a liquid. The sensor is based on the Archimedes buoyancy principle. The sensor consists of a POF bonded on the surface of a metal beam in the form of a cantilever configuration, and at the free end of the beam a displacer is…

  12. Demodulating the Response of Optical Fibre Long-Period Gratings: Genetic Algorithm Approach

    Institute of Scientific and Technical Information of China (English)

    P. S. André; R. A. Sá. Ferreira; C. M. L. Correia; H. Kalinowshy; XIN Xiang-Jun; J. L. Pinto

    2006-01-01

    @@ The extraction of the physical parameters of long period gratings from the spectral response is not an easy process. We present a demodulation technique to synthesize the physical parameters of a long period grating recorded in an optical fibre. The demodulation is achieved through the implementation of a genetic algorithm.The extracted parameters are in agreement with the typical values known for long period gratings.

  13. Railway track component condition monitoring using optical fibre Bragg grating sensors

    Science.gov (United States)

    Buggy, S. J.; James, S. W.; Staines, S.; Carroll, R.; Kitson, P.; Farrington, D.; Drewett, L.; Jaiswal, J.; Tatam, R. P.

    2016-05-01

    The use of optical fibre Bragg grating (FBG) strain sensors to monitor the condition of safety critical rail components is investigated. Fishplates, switchblades and stretcher bars on the Stagecoach Supertram tramway in Sheffield in the UK have been instrumented with arrays of FBG sensors. The dynamic strain signatures induced by the passage of a tram over the instrumented components have been analysed to identify features indicative of changes in the condition of the components.

  14. A Novel Approach to the Sensing of Liquid Density Using a Plastic Optical Fibre Cantilever Beam

    Science.gov (United States)

    Kulkarni, Atul; Kim, Youngjin; Kim, Taesung

    2009-01-01

    This article reports for the first time the use of a plastic optical fibre (POF) cantilever beam to measure the density of a liquid. The sensor is based on the Archimedes buoyancy principle. The sensor consists of a POF bonded on the surface of a metal beam in the form of a cantilever configuration, and at the free end of the beam a displacer is…

  15. Photo- and thermal degradation of olive oil measured using an optical fibre smartphone spectrofluorimeter

    Science.gov (United States)

    Hossain, Md Arafat; Canning, John; Cook, Kevin; Ast, Sandra; Jamalipour, Abbas

    2017-04-01

    Degradation of olive oil under light and heat are analysed using an optical fibre based low-cost portable smartphone spectrofluorimeter. Visible fluorescence bands associated with phenolic acids, vitamins and chlorophyll centred at λ 452, 525 and 670 nm respectively are generated using near-UV excitation (LED λex 370 nm), of extra virgin olive oil are degraded more likely than refined olive oil under light and heat exposure. Packaging is shown to be critical when assessing the origin of degradation.

  16. Design and clinical results from a fibre optic manometry catheter for oesophageal motility studies

    Science.gov (United States)

    Arkwright, J. W.; Doe, S. N.; Smith, M. C.; Blenman, N. G.; Underhill, I. D.; Maunder, S. A.; Glasscock, J. A.; Lim, B.; Szczesniak, M. M.; Dinning, P. G.; Cook, I. J.

    2008-04-01

    We report the design and operation of an optical fibre manometry catheter for measuring variation in pressure in the oesophagus during peristalsis. Catheters of this kind are used to help diagnose oesophageal disorders by recording the muscular contractions of the oesophageal wall in patients having difficulty swallowing. Traditional oesophageal catheters consist of an array of recording sites enabling pressure measurement from multiple locations along the the oesophagus. However, these catheters tend to be bulky or complex to operate whereas our optical equivalent uses a series of Fibre Bragg Grating (FBG) pressure sensors on a single fibre; significantly reducing complexity and allowing the catheter diameter to be minimised. The data from each FBG was recorded using a solid state spectrometer in which the reflected peaks each covered a number of pixels of the spectrometer. This has enabled the FBG peaks to be tracked in wavelength with sub-nanometre precision resulting in pressure sensitivities of less than 1mmHg. Results from a clinical trial carried out on 10 healthy subjects will be presented. For the trial, each subject was simultaneously intubated with the optical catheter and a commercially available solid-state catheter. Back-to-back readings were taken from both devices during a series of controlled water swallows. Ten swallows were recorded with the catheters sensors positioned in proximal, mid, and distal regions of the oesophagus and the data analysed statistically. The fibre optic device accurately picked up the dynamic variations in pressure, and can react at least as fast as the solid state device.

  17. Extending the area of investigation of fine versus coarse quartz optical ages from the Lower Danube to the Carpathian Basin

    OpenAIRE

    Timar-Gabor, Alida; Daniela CONSTANTIN; Marković, S. B.; Jain, Mayank

    2015-01-01

    Despite the general satisfactory performance of quartz in the single aliquot regeneration protocol (SAR), previous optically stimulated luminescence (OSL) dating studies of key loess sections in Romania, Lower Danube region, revealed a disturbing disagreement among the ages obtained on fine (4e11 mm) grains and coarse (63e90 mm) grains respectively. The current study aims at expanding these investigations, both by extending the area of study from the Lower Danube Basin to the Carpathian Basin...

  18. Using optically stimulated electrons from quartz for the estimation of natural doses

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Murray, A.S.; Denby, Phil M.;

    2009-01-01

    quartz samples are studied to examine the possible use of OSE as a chronometer. First the relative variability in OSE and OSL growth curve shapes and the effect of preheat on these are presented, and from these curves, conclusions are drawn concerning the charge movement in natural quartz. Secondly...... dose using the single-aliquot regenerative-dose (SAR) procedure. Finally, a comparative study of the equivalent doses estimated using both OSE and OSL from 10 quartz samples are presented, and it is shown that OSE has a significant potential in retrospective dosimetry....

  19. Active fibre optic splitter for the CMS RPC detector

    Energy Technology Data Exchange (ETDEWEB)

    Banzuzi, Kukka [Helsinki Institute of Physics, University of Helsinki, P.O. Box 64, Gustaf Haellstroemin katu 2, FIN-00014 (Finland)]. E-mail: Kukka.Banzuzi@oxinst.fi; Iskanius, Matti [Lappeenranta University of Technology, P.O, Box 20, Lapprenranta, FIN-53851 (Finland); Karjalainen, Ahti [Lappeenranta University of Technology, P.O, Box 20, Lapprenranta, FIN-53851 (Finland); Tuuva, Tuure [Lappeenranta University of Technology, P.O, Box 20, Lapprenranta, FIN-53851 (Finland)

    2006-09-15

    An electronics module has been designed and tested for the CMS RPC detector readout. The module consists of twelve sub-blocks, each of which receives an optical signal at 1.6 GHz, converts it into electronic form for the splitting process and sends it forth to two or four destinations in optical form. It is a critical part in the trigger system of the experiment. Details of the design are presented, as well as test results confirming that the splitter fulfils all system requirements.

  20. Fibre and components induced limitations in high capacity optical networks

    DEFF Research Database (Denmark)

    Peucheret, Christophe

    2003-01-01

    measurement techniques are first reviewed, and the limitations of the commonly used phase-shift technique is discussed. Additionally, an alternative method which enables the direct determination of small dispersion values in the pass-band of optical filters is proposed. Available optical filter technologies...... km pre-compensated spans. Passive pre distortion at the transmitter is shown to significantly improve the reach of the systems. Based on the experimental results, transparent domains with a diameter of the order of 1000 km can be realised, thus demonstrating the applicability of the optimisation...

  1. Optical birefringence and molecular orientation of crazed fibres utilizing the phase shifting interferometric technique

    Science.gov (United States)

    Sokkar, T. Z. N.; El-Farahaty, K. A.; El-Bakary, M. A.; Omar, E. Z.; Hamza, A. A.

    2017-09-01

    In this article, the features of the phase shifting interferometric technique were utilized to investigate the effect of the presence of crazes in both outer and inner layers on optical birefringence and molecular orientation of polypropylene fibres. The Pluta polarizing interference microscope was used as a phase shifting technique. This method includes adding a stepper motor with a control unit to the micrometer screw of the Pluta microscope. This optical system was calibrated to be used as a phase shifting interferometric technique. The advantage of this technique is that it can detect the crazes in both inner and outer layers of the sample under test. Via this method, the relation between the presence of the crazes (in both inner and outer layers) and the optical molecular orientation of polypropylene (PP) fibres was demonstrated. To clarify the role of this method, the spatial carrier frequency technique was used to show the effect of the presence of the crazes only in the outer layers on the phase distribution values and hence the structural properties of PP fibres.

  2. An Optical Fibre Depth (Pressure) Sensor for Remote Operated Vehicles in Underwater Applications.

    Science.gov (United States)

    Duraibabu, Dinesh Babu; Poeggel, Sven; Omerdic, Edin; Capocci, Romano; Lewis, Elfed; Newe, Thomas; Leen, Gabriel; Toal, Daniel; Dooly, Gerard

    2017-02-19

    A miniature sensor for accurate measurement of pressure (depth) with temperature compensation in the ocean environment is described. The sensor is based on an optical fibre Extrinsic Fabry-Perot interferometer (EFPI) combined with a Fibre Bragg Grating (FBG). The EFPI provides pressure measurements while the Fibre Bragg Grating (FBG) provides temperature measurements. The sensor is mechanically robust, corrosion-resistant and suitable for use in underwater applications. The combined pressure and temperature sensor system was mounted on-board a mini remotely operated underwater vehicle (ROV) in order to monitor the pressure changes at various depths. The reflected optical spectrum from the sensor was monitored online and a pressure or temperature change caused a corresponding observable shift in the received optical spectrum. The sensor exhibited excellent stability when measured over a 2 h period underwater and its performance is compared with a commercially available reference sensor also mounted on the ROV. The measurements illustrates that the EFPI/FBG sensor is more accurate for depth measurements (depth of ~0.020 m).

  3. An Optical Fibre Depth (Pressure Sensor for Remote Operated Vehicles in Underwater Applications

    Directory of Open Access Journals (Sweden)

    Dinesh Babu Duraibabu

    2017-02-01

    Full Text Available A miniature sensor for accurate measurement of pressure (depth with temperature compensation in the ocean environment is described. The sensor is based on an optical fibre Extrinsic Fabry-Perot interferometer (EFPI combined with a Fibre Bragg Grating (FBG. The EFPI provides pressure measurements while the Fibre Bragg Grating (FBG provides temperature measurements. The sensor is mechanically robust, corrosion-resistant and suitable for use in underwater applications. The combined pressure and temperature sensor system was mounted on-board a mini remotely operated underwater vehicle (ROV in order to monitor the pressure changes at various depths. The reflected optical spectrum from the sensor was monitored online and a pressure or temperature change caused a corresponding observable shift in the received optical spectrum. The sensor exhibited excellent stability when measured over a 2 h period underwater and its performance is compared with a commercially available reference sensor also mounted on the ROV. The measurements illustrates that the EFPI/FBG sensor is more accurate for depth measurements (depth of ~0.020 m.

  4. Microcontroller based fibre-optic visual presentation system for multisensory neuroimaging.

    Science.gov (United States)

    Kurniawan, Veldri; Klemen, Jane; Chambers, Christopher D

    2011-10-30

    Presenting visual stimuli in physical 3D space during fMRI experiments carries significant technical challenges. Certain types of multisensory visuotactile experiments and visuomotor tasks require presentation of visual stimuli in peripersonal space, which cannot be accommodated by ordinary projection screens or binocular goggles. However, light points produced by a group of LEDs can be transmitted through fibre-optic cables and positioned anywhere inside the MRI scanner. Here we describe the design and implementation of a microcontroller-based programmable digital device for controlling fibre-optically transmitted LED lights from a PC. The main feature of this device is the ability to independently control the colour, brightness, and timing of each LED. Moreover, the device was designed in a modular and extensible way, which enables easy adaptation for various experimental paradigms. The device was tested and validated in three fMRI experiments involving basic visual perception, a simple colour discrimination task, and a blocked multisensory visuo-tactile task. The results revealed significant lateralized activation in occipital cortex of all participants, a reliable response in ventral occipital areas to colour stimuli elicited by the device, and strong activations in multisensory brain regions in the multisensory task. Overall, these findings confirm the suitability of this device for presenting complex fibre-optic visual and cross-modal stimuli inside the scanner. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. [Fibre optic-assisted endotracheal intubation through the laryngeal mask in children].

    Science.gov (United States)

    Weiss, M; Mauch, J; Becke, K; Schmidt, J; Jöhr, M

    2009-07-01

    Fibre optic-assisted tracheal intubation through the laryngeal mask airway is a simple and safe procedure for securing the airway in the paediatric patient with unexpected and known difficult tracheal intubation. Therefore, fibre optic-assisted tracheal intubation through the laryngeal mask airway represents a standard airway technique and must be part of clinical education and also regular training. However, the removal of the laryngeal mask airway over the tracheal tube is impaired by the short length of the tracheal tube, easily resulting in tube dislocation from the trachea. Among several techniques to overcome this problem, the Cook airway exchange catheter offers a reliable method not only for safe removal of the laryngeal mask over the tracheal tube but also for insertion of an adequate tracheal tube, particularly in paediatric patients. This is particularly important for cuffed tubes as the pilot balloon of the cuffed tube is too large to pass through laryngeal mask airway tubes size 2.5 and smaller. This presentation demonstrates fibre optic-assisted tracheal intubation through the laryngeal mask airway in children step-by-step and discusses its clinical implications. A list with compatible sizes of laryngeal mask airways, tracheal tubes and airway exchange catheters is also provided.

  6. A new fibre optic pulse oximeter probe for monitoring splanchnic organ arterial blood oxygen saturation.

    Science.gov (United States)

    Hickey, M; Samuels, N; Randive, N; Langford, R; Kyriacou, P A

    2012-12-01

    A new, continuous method of monitoring splanchnic organ oxygen saturation (SpO(2)) would make the early detection of inadequate tissue oxygenation feasible, reducing the risk of hypoperfusion, severe ischaemia, and, ultimately, death. In an attempt to provide such a device, a new fibre optic based reflectance pulse oximeter probe and processing system were developed followed by an in vivo evaluation of the technology on seventeen patients undergoing elective laparotomy. Photoplethysmographic (PPG) signals of good quality and high signal-to-noise ratio were obtained from the small bowel, large bowel, liver and stomach. Simultaneous peripheral PPG signals from the finger were also obtained for comparison purposes. Analysis of the amplitudes of all acquired PPG signals indicated much larger amplitudes for those signals obtained from splanchnic organs than those obtained from the finger. Estimated SpO(2) values for splanchnic organs showed good agreement with those obtained from the finger fibre optic probe and those obtained from a commercial device. These preliminary results suggest that a miniaturized 'indwelling' fibre optic sensor may be a suitable method for pre-operative and post-operative evaluation of splanchnic organ SpO(2) and their health.

  7. Asymptotic solutions of glass temperature profiles during steady optical fibre drawing

    KAUST Repository

    Taroni, M.

    2013-03-12

    In this paper we derive realistic simplified models for the high-speed drawing of glass optical fibres via the downdraw method that capture the fluid dynamics and heat transport in the fibre via conduction, convection and radiative heating. We exploit the small aspect ratio of the fibre and the relative orders of magnitude of the dimensionless parameters that characterize the heat transfer to reduce the problem to one- or two-dimensional systems via asymptotic analysis. The resulting equations may be readily solved numerically and in many cases admit exact analytic solutions. The systematic asymptotic breakdown presented is used to elucidate the relative importance of furnace temperature profile, convection, surface radiation and conduction in each portion of the furnace and the role of each in controlling the glass temperature. The models derived predict many of the qualitative features observed in real industrial processes, such as the glass temperature profile within the furnace and the sharp transition in fibre thickness. The models thus offer a desirable route to quick scenario testing, providing valuable practical information about the dependencies of the solution on the parameters and the dominant heat-transport mechanism. © 2013 Springer Science+Business Media Dordrecht.

  8. Erbium Doped Fibre Lasers up t 1618 nm for Optical Communication beyond the L-band

    DEFF Research Database (Denmark)

    Kristensen, Martin; Varming, Poul; Jensen, Jesper Bo

    1999-01-01

    Up to a few months ago it was expected theoretically that erbium doped DFB fibre lasers could not be made to operate at wavelengths above the L-band (1570nm-1610nm). This is due to the combination of very low gain and problems with two-photon absorption in the erbium. In addition semiconductor DFB...... lasers are difficult to get beyond the L-band. Therefore no transmission systems have ever been made in this wavelength region despite that low loss transmission should still be possible in standard fibres. With the increasing demand for optical bandwidth it will soon be essential to use the entire low....../s transmission over 80km with such a DFB fibre laser at 1613nm. Only a minor power penalty was observed compared to standard transmission.We also show that the intrinsic properties of the DFB fibre lasers remain very good at these long wavelengths. We even observe a few dB improvement of the noise...

  9. The optical absorption of gamma irradiated and heat-treated natural quartz

    Directory of Open Access Journals (Sweden)

    Eduardo Henrique Martins Nunes

    2005-09-01

    Full Text Available Quartz with aluminum as impurity absorbs energy from ionizing radiation and modifies its color. Colorless quartz becomes smoky or dark smoky (morion quartz when exposed to gamma rays. By heat-treatment, smoky quartz may become successively greenish, yellowish, or brownish as the irradiation dose increases. Natural, colorless quartz is routinely colored by irradiation with gamma rays and heat-treatment for jewelry production. The color formation in natural quartz through this procedure is explained based on EPR, UV-VIS, and IR studies of irradiated and irradiated and heat-treated samples. Smoky quartz shows absorption bands in the visible region and a strong EPR signal. After heat-treatment it shows absorption bands in the near UV region with extensions into the visible region and a weak EPR signal. The intensity of the absorption bands is proportional to the irradiation dose. These changes of color are explained by the model of Itoh, Stoneham, and Stoneham. [AlSi O4 /h+]0 centers are produced by irradiation, causing the EPR signal and the absorption bands in the visible region. [AlSi O4]- centers are created from [AlSi O4 /h+]0 centers by heat-treatment. They cannot cause an EPR signal and have absorption bands in the near UV region with extensions into the visible region. The highest concentration of [AlSi O4]- centers occurs when the charge compensators have medium mobility. Lithium should give the best condition for color formation. Sodium (low mobility and hydrogen (high mobility should make smoky quartz colorless after heat-treatment.

  10. Dose-dependent optically stimulated luminescence of synthetic quartz at room temperature

    Energy Technology Data Exchange (ETDEWEB)

    Kale, Y.D. [Luminescence Research Laboratory, Applied Physics Department, Faculty of Technology and Engineering, M.S. University of Baroda, Vadodara (India); Gandhi, Y.H. [Luminescence Research Laboratory, Applied Physics Department, Faculty of Technology and Engineering, M.S. University of Baroda, Vadodara (India)], E-mail: yasheshgandhi@yahoo.co.in; Gartia, R.K. [Luminescence Dating Laboratory, Department of Physics, Manipur University, Imphal (India)

    2008-12-15

    Physical conditions such as annealing temperature, duration of annealing, ionizing radiation, etc., play a significant role in the applications of optically stimulated luminescence (OSL) dating as well as OSL dosimetry. Many efforts are made to understand the effect of these physical parameters on quartz specimens owing to its use in such applications. Such factors induce changes in OSL decay pattern. The definite correlation between color centers and luminescence sensitivity can be established on account of such pre-treatments to the specimen. The purpose of present investigations is to study the effect of ionizing radiation under identical physical conditions on OSL properties measured at room temperature. The shapes of decay curve and dose-response data are considered for this purpose. This study can reveal the changes in color centers in response to the pre-conditions to the specimen. It was found that the OSL decay remains slow and OSL properties change systematically with the rise in beta dose up to a critical dose; however, it changes the pattern when the beta exposure to the specimen was increased higher than the critical dose. This critical dose was found to be different for different temperature of annealing. The shape of decay curve up to the critical dose was also studied by considering the difference of OSL intensities between two successive durations from the observed OSL decay data. The results are explained based on the changes in available shallow traps during OSL measurement at room temperature with changes in pre-conditions to the specimens. The results also have been confirmed with the corresponding changes in ESR signals.

  11. Condition monitoring of industrial infrastructures using distributed fibre optic acoustic sensors

    Science.gov (United States)

    Hicke, Konstantin; Hussels, Maria-Teresa; Eisermann, René; Chruscicki, Sebastian; Krebber, Katerina

    2017-04-01

    Distributed fibre optic acoustic sensing (DAS) can serve as an excellent tool for real-time condition monitoring of a variety of industrial and civil infrastructures. In this paper, we portray a subset of our current research activities investigating the usability of DAS based on coherent optical time-domain reflectometry (C-OTDR) for innovative and demanding condition monitoring applications. Specifically, our application-oriented research presented here aims at acoustic and vibrational condition monitoring of pipelines and piping systems, of rollers in industrial heavy-duty conveyor belt systems and of extensive submarine power cable installations, respectively.

  12. Dispersion spreading of biphotons in optical fibres and two-photon interference

    CERN Document Server

    Brida, G; Genovèse, M; Gramegna, M; Krivitsky, L A

    2006-01-01

    We present the first observation of two-photon polarization interference structure in the second-order Glauber's correlation function of two-photon light generated via type-II spontaneous parametric down-conversion. In order to obtain this result, two-photon light is transmitted through an optical fibre and the coincidence distribution is analyzed by means of the START-STOP method. Beyond the experimental demonstration of an interesting effect in quantum optics, these results also have considerable relevance for quantum communications.

  13. Theoretical analysis on double Rayleigh backscattering noise in optical fibre Raman amplifiers and its suppression

    Institute of Scientific and Technical Information of China (English)

    Jiang Wen-Ning; Chen Jian-Ping; Li Xin-Wan; Shang Tao

    2004-01-01

    In this paper, amplified double Rayleigh backscattering noise (DRB) in the optical fibre Raman amplifier is analysed. Expressions are presented for both forward pumping and backward pumping schemes. Calculation is performed to show the effective suppression of DRB noise by employing an optical isolator. The optimal position for the isolator is determined and is found to be insensitive to the power levels of the signals and pumps. The results show that a reduction of the DRB noise by almost 2 to 3 orders can be reached.

  14. Design, Simulation and Optimisation of a Fibre-optic 3D Accelerometer

    Science.gov (United States)

    Yang, Zhen; Fang, Xiao-Yong; Zhou, Yan; Li, Ya-lin; Yuan, Jie; Cao, Mao-Sheng

    2013-07-01

    Using an inertia pendulum comprised of two prisms, flexible beams and an elastic flake, we present a novel fibre-optic 3D accelerometer design. The total reverse reflection of the cube-corner prism and the spectroscopic property of an orthogonal holographic grating enable the measurement of the two transverse components of the 3D acceleration simultaneously, while the longitudinal component can be determined from the elastic deformation of the flake. Due to optical interferometry, this sensor may provide a wider range, higher sensitivity and better resolving power than other accelerometers. Moreover, we use finite element analysis to study the performance and to optimise the structural design of the sensor.

  15. A simplified hollow-core microstructured optical fibre laser with microring resonators and strong radial emission

    Science.gov (United States)

    Li, Zhi-Li; Liu, Yan-Ge; Yan, Min; Zhou, Wen-Yuan; Ying, Cui-Feng; Ye, Qing; Tian, Jian-Guo

    2014-08-01

    A simplified hollow-core microstructured optical fibre (SHMOF) laser with microring resonators and strong radial emission is demonstrated. We propose that a submicron thickness silica ring embedded in the SHMOF can act as a microring resonator, with the advantages of being both compact and solid. Furthermore, the microfluidics can be easily controlled with a side pumping scheme. We also obtained a highly stable and tunable laser. The attractive possibility of developing microfluidic dye lasers within single SHMOFs presents opportunities for integrated optics applications and biomedical analysis.

  16. Preliminary research on monitoring the durability of concrete subjected to sulfate attack with optical fibre Raman spectroscopy

    Science.gov (United States)

    Yue, Yanfei; Bai, Yun; Basheer, P. A. Muhammed; Boland, John J.; Wang, Jing Jing

    2013-04-01

    Formation of ettringite and gypsum from sulfate attack together with carbonation and chloride ingress have been considered as the most serious deterioration mechanisms of concrete structures. Although Electrical Resistance Sensors and Fibre Optic Chemical Sensors could be used to monitoring the latter two mechanisms in situ, currently there is no system for monitoring the deterioration mechanisms of sulfate attack and hence still needs to be developed. In this paper, a preliminary study was carried out to investigate the feasibility of monitoring the sulfate attack with optical fibre Raman spectroscopy through characterizing the ettringite and gypsum formed in deteriorated cementitious materials under an `optical fibre excitation + spectroscopy objective collection' configuration. Bench-mounted Raman spectroscopy analysis was also used to validate the spectrum obtained from the fibre-objective configuration. The results showed that the expected Raman bands of ettringite and gypsum in the sulfate attacked cement paste have been clearly identified by the optical fibre Raman spectroscopy and are in good agreement with those identified from bench-mounted Raman spectroscopy. Therefore, based on these preliminary results, there is a good potential of developing an optical fibre Raman spectroscopy-based system for monitoring the deterioration mechanisms of concrete subjected to the sulfate attack in the future.

  17. A low-cost portable fibre-optic spectrometer for atmospheric absorption studies

    Directory of Open Access Journals (Sweden)

    J. Bailey

    2013-01-01

    Full Text Available A compact and portable solar absorption spectrometer based on fibre-optic Fabry–Perot technology has been built and tested. The instrument weighs only 4.2 kg and operates from 5 W of power from internal batteries. It provides spectroscopy over the range from 5980–6580 cm−1 (1.52–1.67 μm at a resolution of 0.16 cm−1. The input to the spectrometer is via single-mode optical fibre from a solar tracking system. Spectral scanning is carried out with a piezoelectrically scanned fibre Fabry–Perot tunable filter. Software has been developed to calibrate the spectra in wavelength and relative flux. The signal to noise ratio in solar spectra is about 700 for a spectrum scanned at 200 milliseconds per spectral point. The techniques used should be capable of being adapted to a range of wavelengths and to higher or lower resolutions.

  18. Ge-doped optical fibres as thermoluminescence dosimeters for kilovoltage X-ray therapy irradiations

    Energy Technology Data Exchange (ETDEWEB)

    Issa, Fatma, E-mail: f.issa@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Latip, Nur Atiqah Abd; Bradley, David A. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Nisbet, Andrew [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust, Guildford, GU2 7XX (United Kingdom)

    2011-10-01

    We investigate key dosimetric parameters for the thermoluminescence (TL) of Ge-doped silica optical fibres irradiated by X-rays generated at 90 and 300 kVp. The parameters include dose response, reproducibility and fading. Relative dose measurements were performed, obtaining central axis percentage depth dose (PDD) values, use being made of doped fibres irradiated in water and solid water phantoms. TL yields were compared with published data and ionisation chamber measurements. Linearity to dose was demonstrated over the investigated range (0.1-6 Gy), with reproducibility to within{+-}2%. TL fading was found to be minimal, at <1.5% over a 12 h period. The RMI 457 solid water phantom correction factor was found to be 1.155{+-}0.152 and 0.955{+-}0.221 at 90 and 300 kVp, respectively. The maximum discrepancy between PDD values obtained using optical fibres and ionisation chamber measurements was 2.1% at 90 kVp, while the maximum discrepancy between tabulated data and measurements was 1.1% at 300 kVp.

  19. Temperature monitoring using fibre optic sensors in a lead-bismuth eutectic cooled nuclear fuel assembly

    Energy Technology Data Exchange (ETDEWEB)

    De Pauw, B., E-mail: bdepauw@vub.ac.be [Vrije Universiteit Brussel (VUB), Brussels Photonics Team (B-Phot), Brussels (Belgium); Vrije Universiteit Brussel (VUB), Acoustics and Vibration Research Group (AVRG), Brussels (Belgium); Belgian Nuclear Research Centre, (SCK-CEN), Boeretang 200, Mol (Belgium); Lamberti, A.; Ertveldt, J.; Rezayat, A.; Vanlanduit, S. [Vrije Universiteit Brussel (VUB), Acoustics and Vibration Research Group (AVRG), Brussels (Belgium); Van Tichelen, K. [Belgian Nuclear Research Centre, (SCK-CEN), Boeretang 200, Mol (Belgium); Berghmans, F. [Vrije Universiteit Brussel (VUB), Brussels Photonics Team (B-Phot), Brussels (Belgium)

    2016-02-15

    Highlights: • We demonstrate the use of optical fibre sensors in lead-bismuth cooled installations. • In this first of a kind experiment, we focus on temperature measurements of fuel rods • We acquire the surface temperature with a resolution of 30 mK. • We asses the condition of the installation during different steps of the operation. - Abstract: In-core temperature measurements are crucial to assess the condition of nuclear reactor components. The sensors that measure temperature must respond adequately in order, for example, to actuate safety systems that will mitigate the consequences of an undesired temperature excursion and to prevent component failure. This issue is exacerbated in new reactor designs that use liquid metals, such as for example a molten lead-bismuth eutectic, as coolant. Unlike water cooled reactors that need to operate at high pressure to raise the boiling point of water, liquid metal cooled reactors can operate at high temperatures whilst keeping the pressure at lower levels. In this paper we demonstrate the use of optical fibre sensors to measure the temperature distribution in a lead-bismuth eutectic cooled installation and we derive functional input e.g. the temperature control system or other systems that rely on accurate temperature actuation. This first-of-a-kind experiment demonstrates the potential of optical fibre based instrumentation in these environments. We focus on measuring the surface temperature of the individual fuel rods in the fuel assembly, but the technique can also be applied to other components or sections of the installation. We show that these surface temperatures can be experimentally measured with limited intervention on the fuel pin owing to the small geometry and fundamental properties of the optical fibres. The unique properties of the fibre sensors allowed acquiring the surface temperatures with a resolution of 30 mK. With these sensors, we assess the condition of the test section containing the fuel

  20. Determination of fatty acids in the subcutaneous fat of Iberian breed swine by near infrared spectroscopy (NIRS) with a fibre-optic probe.

    Science.gov (United States)

    González-Martín, I; González-Pérez, C; Hernández-Méndez, J; Alvarez-García, N

    2003-10-01

    A near infrared spectrometer equipped with a standard 1210/210 bundle remote reflectance fibre-optic probe, with a 5×5 cm quartz window, was used for the determination of fatty acids in the subcutaneous fat of Iberian pigs. A comparative study was made of the determination of fatty acids (C14:0, C16:0, C18:0, C18:1, C18:2, C18:3, C20: 1, Σpolyunsaturated, Σmonounsaturated and Σsaturated) in samples of subcutaneous fat from Iberian pigs by direct application of the fibre-optic probe on samples of whole subcutaneous fat and with cam-lock cups, assessing extracts of total lipids with diethyl ether. The regression method employed was modified partial least squares (MPLS). Calibration of 157 samples, using the fibre optic probe, allowed determination of fatty acids in the following ranges: C14:0 (0.78-1.77), C16:0 (15.87-29.74), C18:0 (4.61-15.90), C18:1 (43.50-61.27), C18:2 (2.03-13.94), C18:3 (0.13-1.14), C20:1 (0.45-2.32), Σpolyunsaturated (2.31-14.82), Σmonounsaturated (47.37-65.62), Σsaturated (22.09-47.31), with corrected standard errors of prediction SEP(C) of 0.093, 0.56, 0.67, 0.94, 0.42, 0.10, 0.20, 0.46, 0.94, 0.83, respectively. The robustness of the method using the fibre-optic probe was tested in a slaughterhouse using 23 samples for external validation, giving multiple correlation coefficients (RSQ) for C14:0, C16:0, C18:0, C18:1, C18:2, C18:3 C20:1, Σpolyunsaturated, Σmonounsaturated, Σsaturated acids of 0.72, 0.94, 0.72, 0.79, 0.88, 0.55, 0.17, 0.88, 0.74, and 0.90, respectively, and a corrected standard error of prediction [SEP(C)] for these acids (%) of 0.11, 0.60, 0.84, 1.20, 0.77, 0.11, 0.30, 0.76, 1.21, and 1.18, respectively.

  1. Soliton fission and supercontinuum generation in photonic crystal fibre for optical coherence tomography application

    Indian Academy of Sciences (India)

    K Porsezian; R Vasantha Jayakantha Raja

    2015-11-01

    We present a practical design of novel photonic crystal fibre (PCF) to investigate the nonlinear propagation of femtosecond pulses for the application of optical coherence tomography (OCT) based on supercontinuum generation (SCG) process. In addition, this paper contains a brief introduction of the physical phenomena of soliton and SCG. Typically, here we discuss how the ultrabroadband radiation in PCF can be generated by SCG through various nonlinear effects of the fibre. To accomplish the proposed aim, we put forth liquid core PCF (LCPCF) structure filled with chloroform for OCT measurements of the eye. From the proposed design, we observe that proposed LCPCFs with liquid material exhibit significant broadened wavelength spectrum with low input pulse energy over small propagation distances for the OCT application.

  2. Measurement of composite shrinkage using a fibre optic Bragg grating sensor.

    Science.gov (United States)

    Milczewski, M S; Silva, J C C; Paterno, A S; Kuller, F; Kalinowski, H J

    2007-01-01

    Fibre Bragg grating is used to determine resin-based composite shrinkage. Two composite resins (Freedom from SDI and Z100 from 3M) were tested to determine the polymerization contraction behaviour. Each sample of resin was prepared with an embedded fibre Bragg grating. A LED activation unit with wavelength from 430 nm to 470 nm (Dabi Atlante) was used for resin polymerization. The wavelength position of the peak in the optical reflection spectra of the sensor was measured. The wavelength shift was related to the shrinkage deformation of the samples. Temperature and strain evolution during the curing phase of the material was monitored. The shrinkage in the longitudinal direction was 0.15 +/- 0.02% for resin Z100 (3M) and 0.06+/-0.01% for Freedom (SDI); two-thirds of shrinkage occurred after the first 50 s of illumination.

  3. March of the Starbugs: Configuring Fibre-bearing Robots on the UK-Schmidt Optical Plane

    CERN Document Server

    Lorente, Nuria P F; Satorre, Christophe; Hong, Sungwook E; Shortridge, Keith; Goodwin, Michael; Kuehn, Kyler

    2015-01-01

    The TAIPAN instrument, currently being developed for the Australian Astronomical Observatory's UK Schmidt telescope at Siding Spring Observatory, makes use of the AAO's Starbug technology to deploy 150 science fibres to target positions on the optical plane. This paper describes the software system for controlling and deploying the fibre-bearing Starbug robots. The TAIPAN software is responsible for allocating each Starbug to its next target position based on its current position and the distribution of targets, finding a collision-free path for each Starbug, and then simultaneously controlling the Starbug hardware in a closed loop, with a metrology camera used to determine the position of each Starbug in the field during reconfiguration. The software is written in C++ and Java and employs a DRAMA middleware layer (Farrell et al. 1995).

  4. Multi-Rare-Earth Ions Codoped Tellurite Glasses for Potential Dual Wavelength Fibre-Optic Amplifiers

    Institute of Scientific and Technical Information of China (English)

    DAI Shi-Xun; YANG Jian-Hu; XU Shi-Qing; DAI Neng-Li; WEN Lei; HU Li-Li; JIANG Zhong-Hong

    2003-01-01

    A novel co-doping method of multi-rare-earth (RE) ions was demonstrated in tellurite glasses for fibre amplifiers. Fluorescence emissions at both 1.53 and 1.63 fj,m communication windows were Brstly observed from Er3+ /Yb3+ /Tm3+ -codoped tellurite glasses under a single wavelength pumping at 980 nm. The full width at half maximum of Suorescence at 1.53 and 1.63 [im are 55 nm and 50 urn, respectively. Tm's codoping method of three RE ions could be applied to other low photon energy glasses, which would be possibly used for potential dual wavelength fibre-optic amplifiers to broaden the communication windows.

  5. New method to determine the optical rotatory dispersion of inorganic crystals applied to some samples of Carpathian Quartz.

    Science.gov (United States)

    Dimitriu, Dan Gheorghe; Dorohoi, Dana Ortansa

    2014-10-15

    A new method to determine the optical rotatory dispersion (ORD) in the visible range, based on a channeled spectrum obtained with a uniax inorganic crystal introduced between two crossed polarizers with its optical axis parallel to the light propagation direction is detailed in this paper. When the studied inorganic crystals are transparent, this method permits the estimation of the optical rotatory dispersion in the visible range, for which the cheap polarizers are available. The speed of the measurements is very high, because the estimations are made from the channeled spectrum obtained for a single arrangement of the optical components. By using a computer, ORD is quickly determined for the visible range. The results obtained by this method for some Carpathian Quartz samples are consistent with those from literature. The proposed method can be also applied in UV and IR spectral ranges, when the anisotropic layers are transparent and the linearly polarized radiations can be obtained.

  6. Fibre-optic sensors using long-period gratings and microlens arrays

    Science.gov (United States)

    Liu, Michael Shun Yee

    In this project, two fibre-optic sensing systems were developed which use long-period fibre grating (LPG) and Brillouin scattering in single-mode fibre for temperature and bending measurement. In order to realize the LPG grating sensor, two novel LPG fabrication techniques, namely, the microlens array technique and the plano-convex microlens techniques were also developed in this project. The microlens array is characterized by a higher transmission efficiency of UV laser light and higher LPG inscription efficiency than other conventional method, such as the amplitude mask technique. By using the same hydrogen loaded germanosilicate fibre and UV laser irradiation, the microlens array technique can produce an LPG rejection band with a peak loss of -11 dB after 50 seconds of UV laser irradiation while using a metal amplitude mask, a -10.9 dB resonant peak can only be produced after 200 seconds of UV laser irradiation. The microlens array technique was further improved by polishing the microlens array to produce the piano-convex microlens array via which the problems of damage to the microlens array and fibre due to internal focusing and excessive power on the inscription plane were eliminated. Also, the new method is capable of selective control of resonant peaks at higher harmonic frequencies by using the plano-convex microlens array with different polishing depths. In the second stage of the study, a highly sensitive temperature sensor based on a packaged LPG was developed. In addition, a low-cost and high return loss fibre-optic switch was implemented with this packaged LPG. In this project a simple LPG bending sensor was developed which is based on the measurement of total transmitted power, instead of the wavelength shift. It has been shown that the total transmitted power from a LPG has a linear response with respect to the bending curvature within the range from 0 to 0.001 mm-1. Therefore, this kind of LPGs can be used as bending sensors for different

  7. Developing fibre optic Raman probes for applications in clinical spectroscopy.

    Science.gov (United States)

    Stevens, Oliver; Iping Petterson, Ingeborg E; Day, John C C; Stone, Nick

    2016-04-07

    Raman spectroscopy has been shown by various groups over the last two decades to have significant capability in discriminating disease states in bodily fluids, cells and tissues. Recent development in instrumentation, optics and manufacturing approaches has facilitated the design and demonstration of various novel in vivo probes, which have applicability for myriad of applications. This review focusses on key considerations and recommendations for application specific clinical Raman probe design and construction. Raman probes can be utilised as clinical tools able to provide rapid, non-invasive, real-time molecular analysis of disease specific changes in tissues. Clearly the target tissue location, the significance of spectral changes with disease and the possible access routes to the region of interest will vary for each clinical application considered. This review provides insight into design and construction considerations, including suitable probe designs and manufacturing materials compatible with Raman spectroscopy.

  8. Decreased retinal nerve fibre layer thickness detected by optical coherence tomography in patients with ethambutol‐induced optic neuropathy

    Science.gov (United States)

    Chai, Samantha J; Foroozan, Rod

    2007-01-01

    Background It is difficult to assess the degree of optic nerve damage in patients with ethambutol‐induced optic neuropathy, especially just after the onset of visual loss, when the optic disc typically looks normal. Aim To evaluate changes in retinal nerve fibre layer thickness (RNFLT) using optical coherence tomography (OCT) in patients with optic neuropathy within 3 months of cessation of ethambutol treatment. Design A retrospective observational case series from a single neuro‐ophthalmology practice. Methods 8 patients with a history of ethambutol‐induced optic neuropathy were examined within 3 months after stopping ethambutol treatment. All patients underwent a neuro‐ophthalmologic examination, including visual acuity, colour vision, visual fields and funduscopy. OCT was performed on both eyes of each patient using the retinal nerve fibre layer analysis protocol. Results The interval between cessation of ethambutol treatment and the initial visit ranged from 1 week to 3 months. All patients had visual deficits characteristic of ethambutol‐induced optic neuropathy at their initial visit, and the follow‐up examination was performed within 12 months. Compared with the initial RNFLT, there was a statistically significant decrease in the mean RNFLT of the temporal, superior and nasal quadrants (p = 0.009, 0.019 and 0.025, respectively), with the greatest decrease in the temporal quadrant (mean decrease 26.5 μm). Conclusions A decrease in RNFLT is observed in all quadrants in patients with ethambutol‐induced optic neuropathy who have recently discontinued the medication. This decrease is most pronounced in the temporal quadrant of the optic disc. PMID:17215265

  9. Optical fibre multi-parameter sensing with secure cloud based signal capture and processing

    Science.gov (United States)

    Newe, Thomas; O'Connell, Eoin; Meere, Damien; Yuan, Hongwei; Leen, Gabriel; O'Keeffe, Sinead; Lewis, Elfed

    2016-05-01

    Recent advancements in cloud computing technologies in the context of optical and optical fibre based systems are reported. The proliferation of real time and multi-channel based sensor systems represents significant growth in data volume. This coupled with a growing need for security presents many challenges and presents a huge opportunity for an evolutionary step in the widespread application of these sensing technologies. A tiered infrastructural system approach is adopted that is designed to facilitate the delivery of Optical Fibre-based "SENsing as a Service- SENaaS". Within this infrastructure, novel optical sensing platforms, deployed within different environments, are interfaced with a Cloud-based backbone infrastructure which facilitates the secure collection, storage and analysis of real-time data. Feedback systems, which harness this data to affect a change within the monitored location/environment/condition, are also discussed. The cloud based system presented here can also be used with chemical and physical sensors that require real-time data analysis, processing and feedback.

  10. Structural and optical properties analysis of MoS2 nanoflakes on quartz substrate as prepared by mechanical exfoliation

    Science.gov (United States)

    Jaka Adilla, Sandy; Nurfani, Eka; Kurniawan, Robi; Dimas Satrya, Christoforus; Darma, Yudi

    2017-07-01

    We study the structural and optical properties of MoS2 nanoflakes on quartz substrate as prepared by mechanical exfoliation method. The structural and morphological properties of MoS2 nanoflakes were characterized by SEM, EDS, and XRD, while the high-resolution spectroscopic ellipsometry (SE) with the photon energy of 1.27 to 6.53 eV is used to study its optical characteristics. As the results, SEM data shows that MoS2 appears to be nanoflakes covering around 25-35% on the surface of quartz substrate, and XRD spectra shows the dominant orientation along c-axis (002). Based on spectroscopic ellipsometry analysis, the average thickness of MoS2 nanoflakes is around 12 nm or about 6-8 layers. By using Tauc plot method, we confirm that MoS2 nanoflakes have a semiconductor characteristic with the optical bandgap as high as 1.68 eV. Our study shows the important of structural and optical properties of MoS2 nanoflakes that can be utilized for future optoelectronic devices and energy-harvesting purposes.

  11. Get smart, go optical: example uses of optical fibre sensing technology for production optimisation and subsea asset monitoring

    Science.gov (United States)

    Staveley, Chris

    2014-06-01

    With the growth in deep-water oil and gas production, condition monitoring of high-value subsea assets to give early warning of developing problems is vital. Offshore operators can then transport and deploy spare parts before a failure occurs, so minimizing equipment down-time, and the significant costs associated with unscheduled maintenance. Results are presented from a suite of tests in which multiple elements of a subsea twin-screw pump and associated electric motor were monitored using a fibre optic sensing system based on fibre Bragg gratings (FBG) that simultaneously measured dynamic strain on the main rotor bearings, pressure and temperature of the lubricating oil, distributed temperature through the motor stator windings and vibration of the pump and motor housings.

  12. Optically stimulated luminescence techniques in retrospective dosimetry using single grains of quartz extracted from unheated materials

    DEFF Research Database (Denmark)

    Thomsen, Kristina Jørkov

    dosimetry). Special attention has been paid to quartz extracted from unheated building materials such as concrete and mortar. The single-aliquot regeneration-dose (SAR) protocol has been used to determine absorbeddoses in small aliquots as well as single grains of quartz. It is shown that OSL measurements...... that the observed variability in the data is consistent with the sum (in quadrature) of a component,which depends on the number of photons detected from each grain, and a fixed component independent of light level. Dose depth profiles through laboratory irradiated concrete bricks have successfully been measured...

  13. Optimization and kinetics of electroless Ni-P-B plating of quartz optical fiber

    Science.gov (United States)

    Jiang, Boquan; Xiao, Lin; Hu, Shufen; Peng, Jian; Zhang, Hua; Wang, Minwei

    2009-08-01

    The preparation of Ni-P-B coatings on surface of quartz optical fibers was carried out using electroless plating method. The effects of the concentrations of nickel chloride, sodium hypophosphite, potassium borohydride, ethylenediamine, cadmium sulfate and temperature on the quality of Ni-P-B coatings were investigated by orthogonal experiment and their optimal values were determined to be: 0.1 mol L -1, 0.094 mol L -1, 0.185 mol L -1, 0.36 mol L -1, 5.68 × 10 -4 mol L -1 and 90 °C, respectively. The effect of coarsening time of the naked fiber on the quality of Ni-P-B coatings was also researched and the optimal coarsening time was determined to be 15 min. Stereomicroscope, Scanning Electron Microscope and X-ray diffractometer were used to characterize the apparentness, morphology and structure of the prepared Ni-P-B coatings. Inductively Coupled Plasma-Atomic Emission Spectroscopy, Thermal Shock Method and Gravimetric Analysis Method were employed to analyze the composition, force of adhesion and solderability of the coatings, respectively. The results showed that a Ni-P-B coating with low surface roughness, good strength of adhesion, low resistivity and good solderability was successfully prepared. The kinetic models (Ni-P-B deposition rate equations) of the process were established as v=7.95×10-6cA0.830cB0.428cC-0.288cD-0.645cE0..02exp{26788(T-298)298RT; v=1.03×10-7c}/{A0.830cB0.428cC-0.288cD-0.645cE-0.614exp 26788(T-298)298RT. The theoretical values calculated by the models were proved to be basically consistent with the practical measurements through experimental verification.

  14. Effect of alpha and Gaussian refractive index profiles on the design of highly nonlinear optical fibre for efficient nonlinear optical signal processing

    Science.gov (United States)

    Selvendran, S.; Sivanantharaja, A.; Arivazhagan, S.; Kannan, M.

    2016-09-01

    We propose an index profiled, highly nonlinear ultraflattened dispersion fibre (HN-UFF) with appreciable values of fibre parameters such as dispersion, dispersion slope, effective area, nonlinearity, bending loss and splice loss. The designed fibre has normal zero flattened dispersion over S, C, L, U bands and extends up to 1.9857 μm. The maximum dispersion variation observed for this fibre is as low as 1.61 ps km-1 nm-1 over the 500-nm optical fibre transmission spectrum. This fibre also has two zero dispersion wavelengths at 1.487 and 1.9857 μm and the respective dispersion slopes are 0.02476 and 0.0068 ps nm-2 km-1. The fibre has a very low ITU-T cutoff wavelength of 1.2613 μm and a virtuous nonlinear coefficient of 9.43 W-1 km-1. The wide spectrum of zero flattened dispersion and a good nonlinear coefficient make the designed fibre very promising for different nonlinear optical signal processing applications.

  15. Optical cochlear implant: evaluation of insertion forces of optical fibres in a cochlear model and of traumata in human temporal bones.

    Science.gov (United States)

    Balster, Sven; Wenzel, Gentiana I; Warnecke, Athanasia; Steffens, Melanie; Rettenmaier, Alexander; Zhang, Kaiyin; Lenarz, Thomas; Reuter, Guenter

    2014-02-01

    Optical stimulation for hearing restoration is developing as an alternative therapy to electrical stimulation. For a more frequency-specific activation of the auditory system, light-guiding fibres need to be inserted into the coiled cochlea. To enable insertion with minimal trauma, glass fibres embedded in silicone were used as models. Thus, glass fibres of varying core/cladding diameter with and without silicon coating (single as well as in bundles) were inserted into a human scala tympani (ST) model. Insertion cochlear model force measurements were performed, and the thinner glass fibres that showed low insertion forces in the model were inserted into cadaveric human temporal bones. Silicone-coated glass fibres with different core/cladding diameters and bundle sizes could be inserted up to a maximum depth of 20 mm. Fibres with a core/cladding diameter of 50/55 μm break during insertion deeper than 7-15 mm into the ST model, whereas thinner fibres (20/25 μm) could be inserted in the model without breakage and in human temporal bones without causing trauma to the inner ear structures. The insertion forces of silicone-coated glass fibres are comparable to those measured with conventional cochlear implant (CI) electrodes. As demonstrated in human temporal bones, a minimal traumatic implantation of an optical CI may be considered feasible.

  16. Direct implementation of a scalable non-local multi-qubit controlled phase gate via optical fibres and adiabatic passage

    Institute of Scientific and Technical Information of China (English)

    Tang Yao-Xiang; Lin Xiu-Min; Lin Gong-Wei; Chen Li-Bo; Huang Xiu-Hua

    2008-01-01

    This paper presents a direct implementation scheme of the non-local multi-qubit controlled phase gate by using optical fibres and adiabatic passage. The smaller operation number for implementing the multi-qubit controlled phase gate and needlessness for addressing individually save physical resource and lower the difficulties of experiment. Meanwhile, the scheme is immune from some decoherence effects such as the atomic spontaneous emission and fibre loss. In principle, it is scalable.

  17. Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams

    DEFF Research Database (Denmark)

    Aznar, M.C.; Andersen, C.E.; Bøtter-Jensen, L.;

    2004-01-01

    A new optical-fibre radiation dosimeter system, based on radioluminescence and optically stimulated luminescence from carbon-doped aluminium oxide, was developed and tested in clinical photon beams. This prototype offers several features, such as a small detector (1 x 1 x 2 mm), high sensitivity...

  18. Raman Amplification In Optical Fibres In The Wavelength Range 1.06 To 1.36µm

    Science.gov (United States)

    Byron, K. C.

    1985-03-01

    Optical amplification by stimulated Raman emission has been observed at five discrete wavelengths using a fibre Raman laser as both signal and pumping source to the amplifier. An amplification factor of 16 dB has been observed at 1.30 μm and 3 dB at 1.36 μm for a pump power of a few tens of milliwatts. RAMAN AMPLIFICATION IN OPTICAL FIBRES IN THE WAVELENGTH RANGE 1.06 TO 1.36 μm Stimulated Raman scattering in low loss optical fibre waveguides has attracted considerable attention owing to the high efficiency of generation of multiple Stokes frequency shifts. This effect has been utilised to provide a pulsed tunable source for fibre diagnostic measurements (1) , but the direct application of this mechanism for producing amplification of the transmitted signal in a fibre has only recently been investigated, with results showing substantial amplification in GeO2 doped SiO2 fibres at 1.064 μm (2), 1.24 μm (3), and 1.4 μm (4).

  19. Development and application of optical fibre strain and pressure sensors for in-flight measurements

    Science.gov (United States)

    Lawson, N. J.; Correia, R.; James, S. W.; Partridge, M.; Staines, S. E.; Gautrey, J. E.; Garry, K. P.; Holt, J. C.; Tatam, R. P.

    2016-10-01

    Fibre optic based sensors are becoming increasingly viable as replacements for traditional flight test sensors. Here we present laboratory, wind tunnel and flight test results of fibre Bragg gratings (FBG) used to measure surface strain and an extrinsic fibre Fabry-Perot interferometric (EFFPI) sensor used to measure unsteady pressure. The calibrated full scale resolution and bandwidth of the FBG and EFFPI sensors were shown to be 0.29% at 2.5 kHz up to 600 μɛ and 0.15% at up to 10 kHz respectively up to 400 Pa. The wind tunnel tests, completed on a 30% scale model, allowed the EFFPI sensor to be developed before incorporation with the FBG system into a Bulldog aerobatic light aircraft. The aircraft was modified and certified based on Certification Standards 23 (CS-23) and flight tested with steady and dynamic manoeuvres. Aerobatic dynamic manoeuvres were performed in flight including a spin over a g-range  -1g to  +4g and demonstrated both the FBG and the EFFPI instruments to have sufficient resolution to analyse the wing strain and fuselage unsteady pressure characteristics. The steady manoeuvres from the EFFPI sensor matched the wind tunnel data to within experimental error while comparisons of the flight test and wind tunnel EFFPI results with a Kulite pressure sensor showed significant discrepancies between the two sets of data, greater than experimental error. This issue is discussed further in the paper.

  20. Irradiation studies of multimode optical fibres for use in ATLAS front-end links

    CERN Document Server

    Mahout, G; Andrieux, M L; Arvidsson, C B; Charlton, D G; Dinkespiler, B; Dowell, John D; Gallin-Martel, L; Homer, R James; Jovanovic, P; Kenyon, Ian Richard; Kuyt, G; Lundqvist, J M; Mandic, I; Martin, O; Shaylor, H R; Stroynowski, R; Troska, Jan K; Wastie, R L; Weidberg, A R; Wilson, J A; Ye, J

    2000-01-01

    The radiation tolerance of three multimode optical fibres has been investigated to establish their suitability for the use in the front- end data links of the ATLAS experiment. Both gamma and neutron irradiation studies are reported. A step-index fibre with a pure silica core showed an induced attenuation of ~0.05 dB/m at 330 kGy (Si) and 1*10/sup 15/ n(1 MeV Si)/cm/sup 2/ and is suitable for use with the inner detector links which operate at 40-80 Mb/s. A graded- index fibre with a predominantly germanium-doped core exhibits an induced attenuation of ~0.1 dB/m at 800 Gy(Si) and 2*10/sup 13/ n(1 MeV Si)/cm/sup 2/ and is suitable for the calorimeter links which operate at 1.6 Gb/s. Measurements of the dose rate dependence of the induced attenuation indicate that the attenuation in ATLAS will be lower. (30 refs).

  1. Development of evanescent wave absorbance-based fibre-optic biosensor

    Indian Academy of Sciences (India)

    T Kundu; V V R Sai; R Dutta; S Titas; P Kumar; S Mukherjee

    2010-12-01

    Development of chemical and biochemical sensors is the current need of the society. In this report, we present our investigation on the development of a label-free fibre-optic biosensor based on evanescent wave absorbance to detect the presence of analytes such as bacteria, virus and some clinically important proteins. A simple UV-LED (280 nm) and photodetector combination along with a fibre probe was used for developing cost-effective, user-friendly and field applicable device. To improve the sensitivity of the detection technique, the probe design was modified and the U-bent probe was fabricated by simple procedure. Further, to overcome the problems for using UV light source in the fibre, the localized surface plasmon resonance of noble metal nanoparticles at visible wavelength was exploited as a sensing medium for the biochemical reactions. Our systematic studies in this regard presented in this communication may bring the excitement for developing the waterborne pathogen detection device for house-hold as well as field applications.

  2. Characterisation of a fibre optic Raman probe within a hypodermic needle.

    Science.gov (United States)

    Iping Petterson, Ingeborg E; Day, John C C; Fullwood, Leanne M; Gardner, Benjamin; Stone, Nick

    2015-11-01

    We demonstrate the first use of a multifibre Raman probe that fits inside the bore of a hypodermic needle. A Raman probe containing multiple collection fibres provides improved signal collection efficiency in biological samples compared with a previous two-fibre design. Furthermore, probe performance (signal-to-noise ratios) compared favourably with the performance achieved in previous Raman microscope experiments able to distinguish between benign lymph nodes, primary malignancies in lymph nodes and secondary malignancies in lymph nodes. The experimental measurements presented here give an indication of the sampling volume of the Raman needle probe in lymphoid tissues. Liquid tissue phantoms were used that contained scattering medium encompassing a range of scattering properties similar to those of a variety of tissue types, including lymph node tissues. To validate the appropriateness of the phantoms, the sampling depth of the probe was also measured in excised lymph node tissue. More than 50 % of Raman photons collected were found to originate from between the tip of the needle and a depth of 500 μm into the tissue. The needle probe presented here achieves spectral quality comparable to that in numerous studies previously demonstrating Raman disease discrimination. It is expected that this approach could achieve targeted subcutaneous tissue measurements and be viable for use for the in vivo Raman diagnostics of solid organs located within a few centimetres below the skin's surface. Graphical Abstract Schematic of multi-fibre Raman needle probe with disposible tips and proximal optical filtration.

  3. Spectroscopic studies of atomic and molecular species relevant to the optical fibre transmission bands

    CERN Document Server

    Meldau, J

    1995-01-01

    The work presented in this thesis, although all relevant to wavelength standards in the optical fibre transmission windows at 1.3 mu m and 1.55 mu m, can be split into three main parts. Firstly, the work carried out at the University of Strathclyde concerning accurate line position measurements of some molecules having absorption bands at 1.5 mu m ( sup 1 sup 5 NH sub 3 , C sub 2 H sub 2 and sup 1 sup 3 C sup 1 sup 2 CH sub 2) and 1.3 mu m ( sup 1 sup 3 C sub 2 D-2 and sup 1 sup 2 C sub 2 D sub 2) with a Fourier transform spectrometer (FTS). The FTS measurements were undertaken primarily to provide a comprehensive list of fairly strong lines relevant to the optical fibre regions as potential wavelength references for the National Physical Laboratory (NPL). The sup 1 sup 3 C sup 1 sup 2 CH sub 2 overtone and combination bands were assigned and fitted. Secondly, the development of two diode laser spectrometers was carried out at the University of Strathclyde to perform an optical double resonance experiment in ...

  4. High Efficiency Coupling of Optical Fibres with SU8 Micro-droplet Using Laser Welding Process

    Science.gov (United States)

    Yardi, Seema; Gupta, Ankur; Sundriyal, Poonam; Bhatt, Geeta; Kant, Rishi; Boolchandani, D.; Bhattacharya, Shantanu

    2016-09-01

    Apart from micro- structure fabrication, ablation, lithography etc., lasers find a lot of utility in various areas like precision joining, device fabrication, local heat delivery for surface texturing and local change of microstructure fabrication of standalone optical micro-devices (like microspheres, micro-prisms, micro-scale ring resonators, optical switches etc). There is a wide utility of such systems in chemical/ biochemical diagnostics and also communications where the standalone optical devices exist at a commercial scale but chip based devices with printed optics are necessary due to coupling issues between printed structures and external optics. This paper demonstrates a novel fabrication strategy used to join standalone optical fibres to microchip based printed optics using a simple SU8 drop. The fabrication process is deployed for fiber to fiber optical coupling and coupling between fiber and printed SU-8 waveguides. A CO2 laser is used to locally heat the coupling made up of SU8 material. Optimization of various dimensional parameters using design of experiments (DOE) on the bonded assembly has been performed as a function of laser power, speed, cycle control, spot size so on so forth. Exclusive optical [RF] modelling has been performed to estimate the transmissibility of the optical fibers bonded to each other on a surface with SU8. Our studies indicate the formation of a Whispering gallery mode (WGM) across the micro-droplet leading to high transmissibility of the signal. Through this work we have thus been able to develop a method of fabrication for optical coupling of standalone fibers or coupling of on-chip optics with off-chip illumination/detection.

  5. Dispersion-engineered and highly-nonlinear microstructured polymer optical fibres

    DEFF Research Database (Denmark)

    Frosz, Michael Henoch; Nielsen, Kristian; Hlubina, Petr;

    2009-01-01

    We demonstrate dispersion-engineering of microstructured polymer optical fibres (mPOFs) made of poly(methyl methacrylate) (PMMA). A significant shift of the total dispersion from the material dispersion is confirmed through measurement of the mPOF dispersion using white-light spectral....... To increase the nonlinearity of the mPOFs we investigated doping of PMMA with the highly-nonlinear dye Disperse Red 1. Both doping of a PMMA cane and direct doping of a PMMA mPOF was performed....

  6. Smart medical textiles with embedded optical fibre sensors for continuous monitoring of respiratory movements during MRI

    Science.gov (United States)

    Witt, J.; Narbonneau, F.; Schukar, M.; Krebber, K.; De Jonckheere, J.; Jeanne, M.; Kinet, D.; Paquet, B.; Depré, A.; D'Angelo, L. T.; Thiel, T.; Logier, R.

    2010-09-01

    We report on three respiration sensors based on pure optical technologies developed during the FP6 EU project OFSETH. The developed smart medical textiles can sense elongation up to 3%, while maintaining the stretching properties of the textile substrates for a good comfort of the patient. The sensors, based on silica and polymer fibre, are developed for monitoring of patients during MRI examination. The OFSETH harness allows a continuous measurement of respiration movements while all vitals organs are free for medical staff actions. The sensors were tested in MRI environment and on healthy adults.

  7. Bragg grating-based fibre optic sensors in structural health monitoring.

    Science.gov (United States)

    Todd, Michael D; Nichols, Jonathan M; Trickey, Stephen T; Seaver, Mark; Nichols, Christy J; Virgin, Lawrence N

    2007-02-15

    This work first considers a review of the dominant current methods for fibre Bragg grating wavelength interrogation. These methods include WDM interferometry, tunable filter (both Fabry-Perot and acousto-optic) demultiplexing, CCD/prism technique and a newer hybrid method utilizing Fabry-Perot and interferometric techniques. Two applications using these techniques are described: hull loads monitoring on an all-composite fast patrol boat and bolt pre-load loss monitoring in a composite beam in conjunction with a state-space modelling data analysis technique.

  8. Fabrication of microstructured optical fibres by drawing preforms sealed at their top end

    Science.gov (United States)

    Denisov, A. N.; Kosolapov, A. F.; Senatorov, A. K.; Pal'tsev, P. E.; Semjonov, S. L.

    2016-11-01

    This paper presents results of a theoretical analysis and a series of experiments dealing with microstructured optical fibre (MOF) drawing from preforms sealed at their top end. We demonstrate that maintaining a constant temperature in the top part of the preform is of key importance for the ability to produce long MOFs with stable parameters. We have proposed and implemented a technique for additional, controlled heating of the top part of preforms, which allows one to fabricate long MOFs with both constant and varying parameters. Evidence is provided that MOFs with holes differing in size can be produced rather easily by this method.

  9. Towards efficient real-time submarine power cable monitoring using distributed fibre optic acoustic sensors

    Science.gov (United States)

    Hicke, Konstantin; Krebber, Katerina

    2017-04-01

    Online condition monitoring of submarine power cables helps to avert failures and damages produced by mechanical impacts. We report, to our knowledge for the first time, on investigations regarding the feasibility of distributed fiber optic acoustic sensors based on C-OTDR, with the sensor fibers being embedded in the cable, to detect vibrations due to mechanical disturbances along the cable. We present first results of sensing experiments where acoustic signals are transmitted through water to simulate the corresponding submarine conditions. Furthermore, we show results evaluating the usefulness of fibre commonly embedded in existing power cable designs for our sensing purposes.

  10. Space radiation effect on fibre optical gyroscope control circuit and compensation algorithm

    Institute of Scientific and Technical Information of China (English)

    Zhang Chun-Xi; Tian Hai-Ting; Li Min; Jin Jing; Song Ning-Fang

    2008-01-01

    The process of a γ-irradiation experiment of fibre optical gyroscope (FOG) control circuit was described,in which it is demonstrated that the FOG control circuit,except for D/A converter,could endure the dose of 10krad with the protection of cabin material.The distortion and drift in D/A converter due to radiation,which affect the performance of FOG seriously,was indicated based on the elemental analysis.Finally,a compensation network based on adaptive neuro-fuzzy inference system is proposed and its function is verified by simulation.

  11. Terbium-doped gadolinium oxysulfide (Gd2O2S:Tb) scintillation-based polymer optical fibre sensor for real time monitoring of radiation dose in oncology

    Science.gov (United States)

    Lewis, E.; O'Keeffe, S.; Grattan, M.; Hounsell, A.; McCarthy, D.; Woulfe, P.; Cronin, J.; Mihai, L.; Sporea, D.; Santhanam, A.; Agazaryan, N.

    2014-05-01

    A PMMA based plastic optical fibre sensor for use in real time radiotherapy dosimetry is presented. The optical fibre tip is coated with a scintillation material, terbium-doped gadolinium oxysulfide (Gd2O2S:Tb), which fluoresces when exposed to ionising radiation (X-Ray). The emitted visible light signal penetrates the sensor optical fibre and propagates along the transmitting fibre at the end of which it is remotely monitored using a fluorescence spectrometer. The results demonstrate good repeatability, with a maximum percentage error of 0.5% and the response is independent of dose rate.

  12. FOSREM - Fibre-Optic System for Rotational Events&Phenomena Monitoring

    Science.gov (United States)

    Jaroszewicz, Leszek; Krajewski, Zbigniew; Kurzych, Anna; Kowalski, Jerzy; Teisseyre, Krzysztof

    2016-04-01

    We present the construction and tests of fiber-optic rotational seismometer named FOSREM (Fibre-Optic System for Rotational Events&Phenomena Monitoring). This presented device is designed for detection and monitoring the one-axis rotational motions, brought about to ground or human-made structures both by seismic events and the creep processes. The presented system works by measuring Sagnac effect and generally consists of two basic elements: optical sensor and electronic part. The optical sensor is based on so-called the minimum configuration of FOG (Fibre-Optic Gyroscope) where the Sagnac effect produces a phase shift between two counter-propagating light beams proportional to the measured rotation speed. The main advantage of the sensor of this type is its complete insensitivity to linear motions and a direct measurement of rotational speed. It may work even when tilted, moreover, used in continuous mode it may record the tilt. The electronic system, involving specific electronic solutions, calculates and records rotational events data by realizing synchronous in a digital form by using 32 bit DSP (Digital Signal Processing). Storage data and system control are realised over the internet by using connection between FOSREM and GSM/GPS. The most significant attribute of our system is possibility to measure rotation in wide range both amplitude up to 10 rad/s and frequency up to 328.12 Hz. Application of the wideband, low coherence and high power superluminescent diode with long fibre loop and suitable low losses optical elements assures the theoretical sensitivity of the system equal to 2·10-8 rad/s/Sqrt(Hz). Moreover, the FOSREM is fully remote controlled as well as is suited for continuous, autonomous work in very long period of time (weeks, months, even years), so it is useful for systematic seismological investigation at any place. Possible applications of this system include seismic monitoring in observatories, buildings, mines and even on glaciers and in

  13. General demonstration of principal states of polarization and real-time monitoring of polarization mode dispersion in optical fibres

    Institute of Scientific and Technical Information of China (English)

    Dong Hui; Wu Chong-Qing; Fu Song-Nian

    2004-01-01

    We investigated the general properties of polarization effects in optical fibres and demonstrated the existence of socalled principal states of polarization (PSP), which mean the fixed points in mathematics, in different polarization effects,such as birefringence and polarization mode dispersion, by using fixed point theory. Furthermore, a time evolution vector is defined to describe the time evolution of polarization state in optical fibres, which is used to investigate the time evolution of polarization mode dispersion vector (PDV), including differential group delay and PSP. The experimentalresults of real-time monitoring of PDV by using this method are reported. To our knowledge, this is the first report on monitoring PSP evolution in optical fibres.

  14. Optimal spacing between transmitting and receiving optical fibres in reflectance pulse oximetry

    Energy Technology Data Exchange (ETDEWEB)

    Hickey, M; Kyriacou, P A [School of Engineering and Mathematical Sciences, City University, Northampton Square, London, EC1V 0HB (United Kingdom)

    2007-10-15

    Splanchnic ischaemia can ultimately lead to cellular hypoxia and necrosis, and may well contribute to the development of multiple organ failures and increased mortality. Therefore, it is of utmost importance to monitor abdominal organ blood oxygen saturation (SpO{sub 2}). Pulse oximetry has been widely accepted as a reliable method for monitoring oxygen saturation of arterial blood. Animal studies have also shown it to be effective in the monitoring of blood oxygen saturation in the splanchnic region. However, commercially available pulse oximeter probes are not suitable for the continuous assessment of SpO{sub 2} in the splanchnic region. Therefore, there is a need for a new sensor technology that will allow the continuous measurement of SpO{sub 2} in the splanchnic area pre-operatively, operatively and post-operatively. For this purpose, a new fibre optic sensor and processing system utilising the principle of reflectance pulse oximetry has been developed. The accuracy in the estimation of SpO{sub 2} in pulse oximetry depends on the quality and amplitude of the photoplethysmographic (PPG) signal and for this reason an experimental procedure was carried out to examine the effect of the source-detector separation distance on the acquired PPG signals, and to ultimately select an optimal separation for the final design of the fibre-optic probe. PPG signals were obtained from the finger for different separation distances between the emitting and detecting fibres. Good quality PPG signals with large amplitudes and high signal-to-noise ratio were detected in the range of 3mm to 6mm. At separation distances between 1mm and 2mm, PPG signals were erratic with no resemblance to a conventional PPG signal. At separation distances greater than 6mm, the amplitudes of PPG signals were very small and not appropriate for processing. This investigation indicates the suitability of optical fibres as a new pulse oximetry sensor for estimating blood oxygen saturation (SpO{sub 2}) in

  15. Effect of heat treatment on absorption and fluorescence properties of PbS-doped silica optical fibre

    Science.gov (United States)

    Qin, Fu; Dong, Yanhua; Wen, Jianxiang; Pang, Fufei; Luo, Yanhua; Peng, Gang-Ding; Chen, Zhenyi; Wang, Tingyun

    2017-02-01

    The effect of heat treatment on the optical properties of a PbS-doped silica optical fibre was investigated. The experimental results showed that the absorption peak of the fibre red shifted from 1032 to 1133 nm when the heat treatment temperatures were carried out at 900, 950, 1000, and 1100 °C for 1 h, respectively. At the same time, when the heat treatment at 900 °C was carried out for 2, 5, 10, 20, and 40 h, the absorption spectra of the fibre showed a red shift from 1074 to 1143 nm. In addition, the intensity of the absorption peak increased from 0.258 to 1.384 dB/m and the full width at half maximum (FWHM) became narrower (from 130 to 50 nm) as the heat treatment proceeded. Moreover, the photoluminescence (PL) intensity in the wavelength range of 1100-1500 nm decreased with an increase in the heat treatment temperature. The theoretical analysis, using an effective mass method, showed that the effective band gap energy and average size of the lead sulphide (PbS) quantum dots (QDs) in the silica fibre core varied from 1.199 to 1.083 eV and from 4.28 to 4.81 nm, respectively. The results indicate that the size of the PbS QDs present in the silica fibre core could be controlled by a proper heat treatment, which is of great interest in optical fibre amplifiers and other fibre optic devices.

  16. Numerical analysis on using compound parabolic couplers for direct transmission of concentrated solar radiation via optical fibre (Conference Presentation)

    Science.gov (United States)

    Rahou, Maryam; Andrews, John; Rosengarten, Gary

    2016-09-01

    A challenge in high-temperature solar thermal applications is transfer of concentrated solar radiation to the load with minimum energy loss. The use of a solar concentrator in conjunction with optical fibres has potential advantages in terms of transmission efficiency, technical feasibility and cost-effectiveness compared to a conventional heat transfer system employing heat exchangers and a heat transfer fluid. For transferring higher levels of concentrated flux it is necessary to employ multiple optical fibres or fibre bundles. However, the losses at the incident plane of a bundle due to absorption by the epoxy and cladding between the individual fibres in a bundle are substantial, typically over 60% of the overall transmission loss. The optical transmission of the system can thus be enhanced by employing a coupler between the concentrated solar radiation and the entrance to the bundle that reflects all incident light into the cores of individual fibres rather than allowing it to strike the interstitial spaces between the cores. This paper describes the design for such couplers based on multiple compound parabolic (CP) reflectors each with its exit aperture coinciding with the core of an individual fibre within the bundle. The proposed design employs external reflection from a machined metallic aluminium surface. This CP arrangement has the additional benefit of increasing the concentration ratio of the primary solar concentrator used. Simulation modeling using LightTools is conducted into a parabolic Cassegrain solar concentrator employing these CP couplers prior to a fibre bundle. The dependence of overall transmission and total optical efficiency of the system over lengths of the bundle up to 100 m are investigated quantitatively. In addition, the influence on transmission of the angular distribution of radiation intensity at the aperture of the couplers is studied.

  17. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  18. Fast bragg grating inscription in PMMA polymer optical fibres: Impact of thermal pre-treatment of preforms

    DEFF Research Database (Denmark)

    Marques, Carlos A. F.; Pospori, Andreas; Demirci, Gökhan

    2017-01-01

    In this work, fibre Bragg gratings (FBGs) were inscribed in two different undoped poly- (methyl methacrylate) (PMMA) polymer optical fibres (POFs) using different types of UV lasers and their inscription times, temperature and strain sensitivities are investigated. The POF Bragg gratings (POFBGs......) were inscribed using two UV lasers: a continuous UV HeCd @325 nm laser and a pulsed UV KrF @248 nm laser. Two PMMA POFs are used in which the primary and secondary preforms (during the two-step drawing process) have a different thermal treatment. The PMMA POFs drawn in which the primary or secondary...... preform is not specifically pre-treated need longer inscription time than the fibres drawn where both preforms have been pre-annealed at 80 °C for 2 weeks. Using both UV lasers, for the latter fibre much less inscription time is needed compared to another homemade POF. The properties of a POF fabricated...

  19. Uranyl-specific binding at a functionalised interface: a chemophotonic fibre optic sensor platform.

    Science.gov (United States)

    Hayes, Neil W; Tremlett, Clare J; Melfi, Patricia J; Sessler, Jonathon D; Shaw, Andrew M

    2008-05-01

    Detection of radiological materials in the solution phase is restricted by conventional radiation-counting techniques owing to extreme attenuation. Chemical sensing of the resultant radiological species such as uranyl UO(2)(2+) is possible on the surface of a plastic or glass fibre optic. A dihydroxy isoamethryin complex is tethered to the fibre surface which has a large extinction coefficient (119 000 M(-1) cm(-1) at lambda = 439 nm) and changes colour upon binding UO(2)(2+). The spectral changes are greater on the surface than in solution and binding is specific to UO(2)(2+) with small interferences from Gd(3+). Monitoring the spectral response in three detector bands in the red, green and blue enable the optical power change to be measured with sensitivities of 1 mdB, allowing UO(2)(2+) to be detected confidently at 50-100 ppb levels. Real-time kinetic analysis enables discrimination between the target species and possible interferents.

  20. Determination of inorganic elements in animal feeds by NIRS technology and a fibre-optic probe.

    Science.gov (United States)

    González-Martín, Inmaculada; Alvarez-García, Noelia; González-Pérez, Claudio; Villaescusa-García, Virginia

    2006-05-15

    In the present work we study the use of near infra-red spectroscopy (NIRS) technology together with a remote reflectance fibre-optic probe for the analysis of the mineral composition of animal feeds. The method allows immediate control of the feeds without prior sample treatment or destruction through direct application of the fibre-optic probe on the sample. The regression method employed was modified partial least squares (MPLS). The calibration results obtained using forty samples of animal feeds allowed the determination of Fe, Mn, Ca, Na, K, P, Zn and Cu, with a standard error of prediction (SEP(C)) and a correlation coefficient (RSQ) of 0.129 and 0.859 for Fe; 0.175 and 0.816 for Mn; 5.470 and 0.927 for Ca; 2.717 and 0.862 for Na; 4.397 and 0.891 for K; 2.226 and 0.881 for P; 0.153 and 0.764 for Zn, and 0.095 and 0.918 for Cu, respectively. The robustness of the method was checked by applying it to 10 animal feeds samples of unknown mineral composition in the external validation.

  1. Fabrication of integrated optic fibre tip for micron CMMs touch trigger probe application

    Science.gov (United States)

    Ji, H.; Hsu, H. Y.; Chua, J.; Kong, L. X.; Wedding, A. B.; She, M.; Lin, G. C. I.; Fan, K. C.

    2005-12-01

    In the last decade the general miniaturisation of complex products has lead to an increased importance of high precision machining and assembly. Together with increasing precision of products, the need for highly accurate dimensional inspection increases. CMMs (Coordinate Measuring Machines), as a versatile and widespread dimensional metrology tool, can efficiently perform complex measurement with a resolution of about 0.1μm and a repeatability of about 0.3μm. The existing probes for CMMs tend to be very bulky and result in high probing forces for geometrical measurements of high accuracy on small parts. In this paper, an economical flexible method, which is based on optical fibre splicer, is proposed to fabricate an integrated micro scale silicon probe with spherical tip for micron CMMs. Based on Taguchi method, a combination of optimised process parameters has been obtained to control the fabrication conditions that will ensure the manufacturing of tips of a high and consistent quality. With proper control of the process parameters, an optic fibre probe tip with the diameter dimension in the range of 200 to 400μm is achieved and there is a great potential to fabricate a smaller tip with a diameter of 50-100μm in the future.

  2. Optical fibre long period grating spectral actuators utilizing ferrofluids as outclading overlayers

    Science.gov (United States)

    Konstantaki, M.; Candiani, A.; Pissadakis, S.

    2011-03-01

    Results are presented on the spectral tuning of optical fibre long period gratings utilizing water and oil based ferrofluids as outclading overlayers, under static magnetic field stimulus. Two approaches are adopted for modifying the ambient refractive index at the position of the long period grating. In the first approach, a water based ferrofluid is controllably translated along the length of the grating via a magnetic field. Changes as high as 7.5nm and 6.5dB are monitored in the wavelength and strength, respectively, of the attenuation bands of the grating. The repeatable performance of this device for repetitive forward and backward translation verifies that no ferrofluidic residue is left on the fibre, due to silanization cladding functionalisation. In the second approach, the refractive index of an oil based ferrofluidic overlayer is modified through the magneto-optical effect. For an applied static magnetic field in the order of 400 Gauss the strength of the attenuation band of the grating is modified by more than 10% while its spectral position remains unaffected. Accordingly for the implementation of the last approach, the magnetically induced refractive index changes of ferrofluids of different solution concentrations are studied by employing diffraction efficiency measurements.

  3. Ultra-stable optical frequency dissemination on a multi-access fibre network

    CERN Document Server

    Bercy, Anthony; Pottie, Paul-Eric; Amy-Klein, Anne

    2016-01-01

    We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two links of 50-km fibre spools, the extraction being setup at the mid-point of the main link. We show that the extracted signal at the end of the secondary link exhibits fractional frequency instability of 1.4x10-15 at 1-s measurement time, almost equal to the 1.3x10-15 instability of the main link output end. The long-term instabilities are also very similar, at a level of 3-5x10-20 at 3x104-s integration time. We also show that the setting up of this extraction device, or a simpler one, at the main link input, can test the proper functioning of the noise rejection on this main link. This work is a significant step towards...

  4. A simple optical fibre probe for differentiation between healthy and tumorous tissue

    Science.gov (United States)

    Schartner, Erik P.; Henderson, Matthew R.; Purdey, Malcolm; Monro, Tanya M.; Gill, P. Grantley; Callen, David F.

    2016-11-01

    Incomplete removal of malignant tumours continues to be a significant issue in cancer surgery. It increases the risk of local recurrence and impaired survival, and results in the need for additional surgery with associated attendant costs and morbidity. While pathological methods exist to determine tissue type during surgery, these methods can compromise post-operative pathology, have a lag of minutes to hours before the surgeon receives the results of the tissue analysis and are restricted to excised tissue. In this work we report the development of an optical fibre probe which could find use as an aid for margin detection during surgery. A fluorophore doped polymer coating is deposited on the tip of an optical fibre, which can then be used to record the pH by monitoring the emission spectra from the embedded indicator. The pH values of unknown tissue are measured and compared to healthy tissue, allowing for discrimination between healthy and cancerous tissue. The probe developed here shows strong potential for use during surgery, as the probe design can be readily adapted to a low-cost portable configuration which could find use in the operating theatre. Use of this probe in surgery either on excised or in-vivo tissue has the potential to improve success rates for complete removal of cancers.

  5. Establishment of Ge-doped optical fibres as thermoluminescence dosimeters for brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Issa, Fatma, E-mail: f.issa@surrey.ac.uk [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Radiotherapy, Tripoli Medical Centre (TMC), Tripoli (Libya); Abdul Rahman, A.T. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); School of Physics and Material Studies, Faculty of Applied Sciences, Universiti Teknologi MARA Malaysia, Campus of Negeri Sembilan, 72000 Kuala Pilah (Malaysia); Hugtenburg, Richard P. [Department of Medical Physics and Clinical Engineering, Abertawe Bro Morgannwg UHB and School of Medicine, Swansea University, Swansea, SA2 8PP (United Kingdom); Bradley, David A. [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Radiological Sciences, King Saud University, P.O. Box 10219, Riyadh 11432 (Saudi Arabia); Nisbet, Andrew [Department of Physics, University of Surrey, Guildford, GU2 7XH (United Kingdom); Department of Medical Physics, Royal Surrey County Hospital NHS Foundation Trust, Guildford, GU2 7XX (United Kingdom)

    2012-07-15

    This study aims to establish the sensitive, {approx}120 {mu}m high spatial resolution, high dynamic range Ge-doped optical fibres as thermoluminescence (TL) dosimeters for brachytherapy dose distribution. This requires investigation to accommodate sensitivity of detection, both for the possibility of short range dose deposition from beta components as well as gamma/x-mediated dose. In-air measurements are made at distances close to radionuclide sources, evaluating the fall off in dose along the transverse axis of {sup 133}Ba and {sup 60}Co radioactive sources, at distances from 2 mm up to 20 mm from their midpoints. Measurements have been compared with Monte Carlo code DOSRZnrc simulations for photon-mediated dose only, agreement being obtained to within 3% and 1% for the {sup 133}Ba and {sup 60}Co sources, respectively. As such, in both cases it is determined that as intended, beta dose has been filtered out by source encapsulation. - Highlights: Black-Right-Pointing-Pointer We seek to establish Ge-doped optical fibres as TLDs for brachytherapy. Black-Right-Pointing-Pointer Dose was evaluated along the central axis of {sup 133}Ba and {sup 60}Co, at 2 mm-20 mm. Black-Right-Pointing-Pointer We verify values using DOSRZnrc Monte Carlo code simulations. Black-Right-Pointing-Pointer Good agreement is between dose measurements and calculation to within 3% and 1%. Black-Right-Pointing-Pointer Methodology is to be used in obtaining doses around {sup 125}I and {sup 192}Ir sources.

  6. Optical properties and thermal stability of germanium oxide (GeO{sub 2}) nanocrystals with {alpha}-quartz structure

    Energy Technology Data Exchange (ETDEWEB)

    Ramana, C.V., E-mail: rvchintalapalle@utep.edu [Department of Mechanical Engineering, University of Texas at El Paso, El Paso, TX 79968 (United States); Department of Materials Science and Engineering, University of Texas at El Paso, El Paso, TX 79968 (United States); Carbajal-Franco, G. [Department of Materials Science and Engineering, University of Texas at El Paso, El Paso, TX 79968 (United States); Vemuri, R.S. [Department of Mechanical Engineering, University of Texas at El Paso, El Paso, TX 79968 (United States); Department of Materials Science and Engineering, University of Texas at El Paso, El Paso, TX 79968 (United States); Troitskaia, I.B. [Laboratory of Optical Materials and Structures, Institute of Semiconductor, Physics SB RAS, Novosibirsk 630090 (Russian Federation); Gromilov, S.A. [Laboratory of Crystal Chemistry, Institute of Inorganic Chemistry, SB RAS, Novosibirsk 630090 (Russian Federation); Atuchin, V.V. [Laboratory of Optical Materials and Structures, Institute of Semiconductor, Physics SB RAS, Novosibirsk 630090 (Russian Federation)

    2010-10-25

    Germanium dioxide (GeO{sub 2}) crystals were prepared by a chemical precipitation method at a relatively low-temperature (100 {sup o}C). The grown crystals were characterized by studying their microstructure, optical properties and thermal stability. The results indicate that the grown GeO{sub 2} crystals exhibit {alpha}-quartz type crystal structure. The lattice parameters obtained from XRD were a = 4.987(4) A and c = 5.652(5) A. Electron microscopy analysis indicates a high structural quality of GeO{sub 2} crystals grown using the present approach. Optical absorption measurements indicate a direct bandgap of 5.72 eV without any additional bands arising from localized or defect states. Thermogravimetric measurements indicate the temperature stability of the grown GeO{sub 2} nanocrystals. Microscopic analysis coupled with energy dispersive X-ray spectroscopy of the GeO{sub 2} crystals with {alpha}-quartz type crystal structure indicates their stability in chemical composition up to a temperature of 400 deg. C. The surface morphology of GeO{sub 2} crystals, however, found to be changing with the increase in temperature.

  7. A Study on Protection of Cables by Solkor Differential Protection Relay with Fibre Optic Pilot Wireor Metallic Pilot Wire

    Directory of Open Access Journals (Sweden)

    Ahmed Rashad .E. Bakr

    2015-02-01

    Full Text Available This paper intends to briefly compare the protection of buried three phase high voltage cable with Solkordifferential protection relay using metallic pilot wires orfibre optic pilot wires. Dielectric property of the fiber optic provides complete electrical isolation as well as interference free signaling. This provides total immunity from GPR (ground potential rise, longitudinal induction, and differential mode noise coupling andhigh-voltage hazards to personnel safety. So Fibre optic provides great advantage for Solkor differential protection relaying.

  8. Potential clinical utility of a fibre optic-coupled dosemeter for dose measurements in diagnostic radiology.

    Science.gov (United States)

    Jones, A Kyle; Hintenlang, David

    2008-01-01

    Many types of dosemeters have been investigated for absorbed dose measurements in diagnostic radiology, including ionisation chambers, metal-oxide semiconductor field-effect transistor dosemeters, thermoluminescent dosemeters, optically stimulated luminescence detectors, film and diodes. Each of the aforementioned dosemeters suffers from a critical limitation, either the need to interrogate, or read, the dosemeter to retrieve dose information or large size to achieve adequate sensitivity. This work presents an evaluation of a fibre optic-coupled dosemeter (FOCD) for use in diagnostic radiology dose measurement. This dosemeter is small, tissue-equivalent and capable of providing true real-time dose information. The FOCD has been evaluated for dose linearity, angular dependence, sensitivity and energy dependence at energies, beam qualities and beam quantities relevant to diagnostic radiology. The FOCD displayed excellent dose linearity and high sensitivity, while exhibiting minimal angular dependence of response. However, the dosemeter does exhibit positive energy dependence, and is subject to attenuation of response when bent.

  9. Towards optical fibre based Raman spectroscopy for the detection of surgical site infection

    Science.gov (United States)

    Thompson, Alex J.; Koziej, Lukasz; Williams, Huw D.; Elson, Daniel S.; Yang, Guang-Zhong

    2016-03-01

    Surgical site infections (SSIs) are common post-surgical complications that remain significant clinical problems, as they are associated with substantial mortality and morbidity. As such, there is significant interest in the development of minimally invasive techniques that permit early detection of SSIs. To this end, we are applying a compact, clinically deployable Raman spectrometer coupled to an optical fibre probe to the study of bacteria, with the long term goal of using Raman spectroscopy to detect infection in vivo. Our system comprises a 785 nm laser diode for excitation and a commercial (Ocean Optics, Inc.) Raman spectrometer for detection. Here we discuss the design, optimisation and validation of this system, and describe our first experiences interrogating bacterial cells (Escherichia coli) in vitro.

  10. Structural and optical characterization of ZrO2 thin films grown on silicon and quartz substrates

    Science.gov (United States)

    Hojabri, Alireza

    2016-09-01

    Zirconium oxide thin films were grown successfully by thermal annealing of zirconium thin films deposited on quartz and silicon substrates by direct current magnetron sputtering technique. The structural and optical properties in relation to thermal annealing times were investigated. The X-ray diffraction patterns revealed that structure of films changes from amorphous to crystalline by increase of annealing times in range 60-240 min. The composition of films was determined by Rutherford back scattering spectroscopy. Atomic force microscopy results exhibited that surface morphology and roughness of films depend on the annealing time. The refractive index of the films was calculated using Swanepoel's method. The optical band gap energy of annealed films decreased from 5.50 to 5.34 eV with increasing thermal annealing time.

  11. Efficient delivery of 60 J pulse energy of long pulse Nd:YAG laser through 200 m core diameter optical fibre

    Indian Academy of Sciences (India)

    Ravindra Singh; Ambar Choubey; R K Jain; S C Vishwakarma; D K Agrawal; Sabir Ali; B N Upadhyaya; S M Oak

    2014-02-01

    Most of today’s industrial Nd:YAG lasers use fibre-optic beam delivery. In such lasers, fibre core diameter is an important consideration in deploying a beam delivery system. Using a smaller core diameter fibre allows higher irradiances at focus position, less degradation of beam quality, and a larger stand-off distance. In this work, we have put efforts to efficiently deliver the laser output of ‘ceramic reflector’-based long pulse Nd:YAG laser through a 200 m core diameter optical fibre and successfully delivered up to 60 J of pulse energy with 90% transmission efficiency, using a GRADIUM (axial gradient) plano-convex lens to sharply focus down the beam on the end face of the optical fibre and fibre end faces have been cleaved to achieve higher surface damage thresholds.

  12. Optically stimulated phosphorescence in quartz over the millisecond to second time scale: insights into the role of shallow traps in delaying luminescent recombination

    DEFF Research Database (Denmark)

    Ankjærgaard, Christina; Jain, Mayank

    2010-01-01

    Time-resolved optically stimulated luminescence (TR-OSL) curves from quartz are usually measured over a few hundred microseconds because this time range best illustrates the main component in quartz which lies in the range 30–45 µs. In this study we present the decay form of quartz TR......-OSL and optically stimulated phosphorescence (OSP) covering over 8 orders of magnitude from 50 ns to ~8 s. A detailed characterization of the previously unstudied slowly decaying signals (millisecond–second time scales) is undertaken to understand the origin of these components and the role of re-trapping following...... optical stimulation. We present preheat and stimulation temperature dependence for both the TR-OSL and OSP curves in these time ranges and use the latter data to determine the E and s values for the participating shallow traps. We observe an abnormal decay behaviour seen as a sudden increase in the decay...

  13. Blue light emitting diodes for optical stimulation of quartz in retrospective dosimetry and dating

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Duller, G.A.T.; Murray, A.S.

    1999-01-01

    (470 nm) gives order of magnitude greater rate of stimulation in quartz than that from conventional blue-green light filtered from a halogen lamp. A practical blue LED OSL configuration is described. From comparisons of OSL decay curves produced by green and blue light sources, and by examination...... advantages that the life-time is indefinite, and the output can be controlled electronically; this allows the power to be readily controlled by software. Unlike a filtered light source, there are no electromechanical parts, and the switch on/off times are about 10 times faster than a shutter. Finally...

  14. Ultra-high and persistent optical depths of caesium in Kagom\\'e-type hollow-core photonic crystal fibres

    CERN Document Server

    Kaczmarek, Krzysztof T; Sprague, Michael R; Kolthammer, W Steven; Feizpour, Amir; Ledingham, Patrick M; Brecht, Benjamin; Poem, Eilon; Abdolvand, Amir; Russell, Philip St J; Walmsley, Ian A; Nunn, Joshua

    2015-01-01

    Alkali-filled hollow-core fibres are a promising medium for investigating light-matter interactions, especially at the single-photon level, due to the tight confinement of light and high optical depths achievable by light-induced atomic desorption. However, until now these large alkali vapour densities could only be generated for seconds at most once per day, severely limiting the practicality of the technology. Here we report the generation of highest observed transient ($>10^5$ for minutes) and highest observed persistent (>2000 for hours) optical depths of alkali vapours in hollow-core fibres to date, using a caesium-filled Kagom\\'e-type hollow-core photonic crystal fibre. Our results pave the way to light-matter interaction experiments in confined geometries requiring long operation times and large atomic number densities, such as single-photon-level light-matter interaction experiments and fundamental investigations of hot dense atomic gases.

  15. Theoretical modelling of a bi-dimensional U-shaped surface plasmon resonance based fibre optic sensor for sensitivity enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Verma, R K; Gupta, B D [Physics Department, Indian Institute of Technology Delhi, New Delhi-110016 (India)], E-mail: bdgupta@physics.iitd.ernet.in

    2008-05-07

    Theoretical analysis of a surface plasmon resonance based fibre optic sensor with a uniform semi-metal coated U-shaped probe is carried out using a bi-dimensional model. All the rays of the p-polarized light launched in the fibre and their electric vectors are assumed to be confined in the plane of bending of the U-shaped probe. The effect of the bending radius of the probe on the sensitivity of the sensor is studied. The study shows that as the bending radius of the probe decreases the sensitivity of the sensor increases. For the light launching conditions used, the maximum sensitivity achieved is several times more than that reported for a fibre optic tapered probe. In addition to high sensitivity, the most advantageous feature of a U-shaped probe is that it can be used as a point sensor.

  16. Characteristics of thermally transferred optically stimulated luminescence (TT-OSL) in quartz and its potential for dating sediments

    Energy Technology Data Exchange (ETDEWEB)

    Tsukamoto, Sumiko [Institute of Geography and Earth Sciences, Aberystwyth University, Aberystwyth SY23 3DB (United Kingdom); Duller, Geoff A.T. [Institute of Geography and Earth Sciences, Aberystwyth University, Aberystwyth SY23 3DB (United Kingdom)], E-mail: ggd@aber.ac.uk; Wintle, Ann G. [Institute of Geography and Earth Sciences, Aberystwyth University, Aberystwyth SY23 3DB (United Kingdom)

    2008-08-15

    The temperature dependence, dose response and bleaching characteristics of the thermally transferred optically stimulated luminescence (TT-OSL) of sedimentary quartz were studied, in order to assess the potential of the TT-OSL signal for dating. The TT-OSL was separated into two components; recuperated OSL (ReOSL) and basic transfer (BT-OSL) by annealing samples at 300 deg. C for 10 s as suggested in an earlier study. Four quartz extracts were studied, two from loess from China and two from coastal sands from South Africa. The equivalent doses of the two recent samples (one sand and one loess) were {approx}15Gy and this suggests that the signal can be bleached by sunlight but may not be totally zeroed. The sensitivity-corrected ReOSL from the older samples did not reach zero and gave doses of 14 and 52 Gy, respectively, after 7 days bleaching with a solar simulator. A single aliquot regenerative dose (SAR) protocol using ReOSL was proposed and tested. In this protocol, a blue light stimulation at 280 deg. C for 100 s at the end of each cycle resulted in the recovery of identical sensitivity-corrected ReOSL values, in spite of {approx}20 -30% loss in sensitivity for the four samples that were tested. Two dose response curves were constructed using the sensitivity-corrected ReOSL, one for the initial 2 s signal and the other for the fast component obtained by curve fitting. Using the additional high temperature bleach and the separated fast component of the ReOSL, it was possible to recover given doses within 10%, up to {approx}1000Gy for the loess and {approx}2000Gy for the coarse grained quartz. However, the natural dose obtained for the older sand was twice that obtained using the conventional SAR OSL method.

  17. Generation of Optical Vortex Using a Spiral Phase Plate Fabricated in Quartz by Direct Laser Writing and Inductively Coupled Plasma Etching

    Institute of Scientific and Technical Information of China (English)

    CHEN Jun; KUANG Deng-Feng; GUI Min; FANG Zhi-Liang

    2009-01-01

    A simple, economical and reliable technique is proposed for fabricating a spiral phase plate (SPP) in a quartz substrate to generate optical vortex with a unit topological charge at the wavelengths of 632.8nm. The spiral phase plate is first formed in the photoresist by direct laser writing lithography and then transferred into the quartz substrate by inductively coupled plasma etching. The performance of the fabricated SPP is verified by using beam intensity distribution, which is in agreement with the theoretical calculation result. The interference measurement suggests that we have succeeded to generate opticM vortex with a unit topological charge with the fabricated SPP.

  18. Optical fibre pressure and temperature sensor system designed for urodynamic applications

    Science.gov (United States)

    Duraibabu, Dineshbabu; Kelly, Niall; Poeggel, Sven; Flood, Hugh; Yuan, Hongwei; Dooly, Gerard; McGrath, Deirdre; Tosi, Daniele; Lewis, Elfed; Leen, Gabriel

    2016-05-01

    This paper presents an optical fibre pressure and temperature sensor (OFPTS) system, which is adapted for use as a urodynamic pressure measurement system (UPS) for differential pressure measurement with temperature compensation. The OFTPS is based on a Fabry Perot interferometer (FPI), which acts as a pressure sensor and includes an embedded fibre Bragg grating (FBG) for temperature measurement. The sensor system is evaluated in a lower urinary tract (LUT) simulator, which simulates the bladder, rectum and detrusor muscle. The system was benchmarked against a commercially available urodynamic system, at the University Hospital Limerick (UHL) Urology Clinic. Both systems demonstrate a high correlation with a relative pressure variation of less than +/-2.8cmH2O for abdominal and +/-4cmH2O for vesical pressure. The repetitive measurement of the OFPTS system in the LUT simulator against the commercial system demonstrated the high repeatability. Furthermore, the low fabrication cost makes the OFPTS a potentially interesting instrument for urodynamic and other medical applications.

  19. Measurement of stress-strain behaviour of human hair fibres using optical techniques.

    Science.gov (United States)

    Lee, J; Kwon, H J

    2013-06-01

    Many studies have presented stress-strain relationship of human hair, but most of them have been based on an engineering stress-strain curve, which is not a true representation of stress-strain behaviour. In this study, a more accurate 'true' stress-strain curve of human hair was determined by applying optical techniques to the images of the hair deformed under tension. This was achieved by applying digital image cross-correlation (DIC) to 10× magnified images of hair fibres taken under increasing tension to estimate the strain increments. True strain was calculated by summation of the strain increments according to the theoretical definition of 'true' strain. The variation in diameter with the increase in longitudinal elongation was also measured from the 40× magnified images to estimate the Poisson's ratio and true stress. By combining the true strain and the true stress, a true stress-strain curve could be determined, which demonstrated much higher stress values than the conventional engineering stress-strain curve at the same degree of deformation. Four regions were identified in the true stress-strain relationship and empirical constitutive equations were proposed for each region. Theoretical analysis on the necking condition using the constitutive equations provided the insight into the failure mechanism of human hair. This analysis indicated that local thinning caused by necking does not occur in the hair fibres, but, rather, relatively uniform deformation takes place until final failure (fracture) eventually occurs.

  20. Plastic Optical Fibre Sensor for Spine Bending Monitoring with Power Fluctuation Compensation

    Directory of Open Access Journals (Sweden)

    Mohd Anwar Zawawi

    2013-10-01

    Full Text Available This paper presents the implementation of power fluctuation compensation for an intensity-based optical fibre bending sensor aimed at monitoring human spine bending in a clinical environment. To compensate for the light intensity changes from the sensor light source, a reference signal was provided via the light reflection from an aluminum foil surface fixed at a certain distance from the source fibre end tips. From the results, it was found that the investigated sensor compensation technique was capable of achieving a 2° resolution for a bending angle working range between 0° and 20°. The study also suggested that the output voltage ratio has a 0.55% diversion due to input voltage variation between 2.9 V and 3.4 V and a 0.25% output drift for a 2 h measurement. With the achieved sensor properties, human spine monitoring in a clinical environment can potentially be implemented using this approach with power fluctuation compensation.

  1. Prospective Study on Retinal Nerve Fibre Layer Thickness Changes in Isolated Unilateral Retrobulbar Optic Neuritis

    Directory of Open Access Journals (Sweden)

    Gordon S. K. Yau

    2013-01-01

    Full Text Available Purpose. To investigate the retinal nerve fibre layer (RNFL thickness after unilateral acute optic neuritis using optical coherence tomography (OCT. Patients and Methods. This prospective cohort study recruited consecutive patients with a first episode of isolated, unilateral acute optic neuritis. RNFL thickness and visual acuity (VA of the attack and normal fellow eye were measured at presentation and 3 months in both the treatment and nontreatment groups. Results. 11 subjects received systemic steroids and 9 were treated conservatively. The baseline RNFL thickness was similar in the attack and fellow eye (P≥0.4. At 3 months, the attack eye had a thinner temporal (P=0.02 and average (P=0.05 RNFL compared to the fellow eye. At 3 months, the attack eye had significant RNFL thinning in the 4 quadrants and average thickness (P≤0.0002 compared to baseline. The RNFL thickness between the treatment and nontreatment groups was similar at baseline and 3 months (P≥0.1. Treatment offered better VA at 3 months (0.1 ± 0.2 versus 0.3 ± 0.2 LogMAR, P=0.04. Conclusion. Generalized RNFL thinning occurred at 3 months after a first episode of acute optic neuritis most significantly in the temporal quadrant and average thickness. Visual improvement with treatment was independent of RNFL thickness.

  2. Experimental Investigation of Pump-to-Signal Noise Transfer in One-Pump Phase Insensitive Fibre Optic Parametric Amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lund-Hansen, Toke; Peucheret, Christophe

    2011-01-01

    This paper presents a detailed experimental characterization of the relative intensity noise (RIN) transferred from the pump to the signal in one-pump phase insensitive fibre optic parametric amplifiers. We extend an existing experimental and theoretical work towards higher frequencies, showing...

  3. Limitations in distance and frequency due to chromatic dispersion in fibre-optic microwave and millimeter-wave links

    DEFF Research Database (Denmark)

    Gliese, Ulrik Bo; Nielsen, Søren Nørskov

    1996-01-01

    Chromatic dispersion significantly limits the distance and/or frequency in fibre-optic microwave and millimeter-wave links based on direct detection due to a decrease of the carrier to noise ratio. The limitations in links based on coherent remote heterodyne detection, however, are far less...

  4. Single-Mode Propagation in Optical Waveguides and Fibres: A Critical Review of its Treatment in Physics Textbooks

    Science.gov (United States)

    Ruddock, Ivan S.

    2009-01-01

    The derivation and description of the modes in optical waveguides and fibres are reviewed. The version frequently found in undergraduate textbooks is shown to be incorrect and misleading due to the assumption of an axial ray of light corresponding to the lowest order mode. It is pointed out that even the lowest order must still be represented in…

  5. Distributed fibre optic temperature measurement system for the safety monitoring of the next generation of large nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez Fernandez, Alberto; Brichard, Benoit [SCK-CEN, Belgian Nuclear Research Center (Belgium); Hartog, Arthur H.; Hughes, Paul [SENSA, a Schlumberger Company (United Kingdom)

    2006-07-01

    The use of optical fibre distributed sensors for temperature sensing is a powerful way of monitoring, quasi simultaneously, thousands of points avoiding the requirement of optimum positioning of discrete temperature sensors. Their range of applications is rapidly expanding in the industry, and nowadays this fibre optic sensing technology is mature for industrial applications such as fire detection inside buildings and tunnels, process vessel monitoring, leak detection in cryogenic storage vessels (liquid natural gas (LNG), ammonia, ethylene) or oil wells and the measurement of energy cable thermal distribution for the power supply industry. These applications rely on the well known immunity of fibre optic sensors to electromagnetic interference and the ability of fibre sensors to be operated in hazardous environments. The nuclear industry shows a growing interest for the possibilities offered for temperature sensing applications. Fibre optic sensing technology could be considered as an alternative to classical measurements techniques in a wide range of applications. The potential of distributed temperature measurements for the monitoring of large nuclear infrastructures such as reactor containment buildings, nuclear waste repositories and reactor primary circuitry have already been shown. However, a major problem in the application of optical fibres in nuclear environments is the presence of ionizing radiation fields that induce an increase of the optical fibre attenuation. This radiation-induced degradation of the measurement signal could be critical since most commercially available distributed temperature sensors derive the temperature profile from the measurement of the Raman backscattered light intensity along the fibre, using optical time domain reflectometry techniques. The Raman signal comprises two elements: the Stokes and anti-Stokes lines. The longer wavelength Stokes line is only weakly temperature sensitive but the intensity of the backscattered light

  6. Review of doped silica glass optical fibre: their TL properties and potential applications in radiation therapy dosimetry.

    Science.gov (United States)

    Bradley, D A; Hugtenburg, R P; Nisbet, A; Abdul Rahman, Ahmad Taufek; Issa, Fatma; Mohd Noor, Noramaliza; Alalawi, Amani

    2012-12-01

    Review is made of dosimetric studies of Ge-doped SiO(2) telecommunication fibre as a 1-D thermoluminescence (TL) system for therapeutic applications. To-date, the response of these fibres has been investigated for UV sources, superficial X-ray beam therapy facilities, a synchrotron microbeam facility, electron linear accelerators, protons, neutrons and alpha particles, covering the energy range from a few eV to several MeV. Dosimetric characteristics include, reproducibility, fading, dose response, reciprocity between TL yield and dose-rate and energy dependence. The fibres produce a flat response to fixed photon and electron doses to within better than 3% of the mean TL distribution. Irradiated Ge-doped SiO(2) optical fibres show limited signal fading, with an average loss of TL signal of ~0.4% per day. In terms of dose response, Ge-doped SiO(2) optical fibres have been shown to provide linearity to x and electron doses, from a fraction of 1 Gy up to 2 kGy. The dosimeters have also been used in measuring photoelectron generation from iodinated contrast media; TL yields being some 60% greater in the presence of iodine than in its absence. The review is accompanied by previously unpublished data.

  7. Fibre Optic Laser Doppler Anemometry, The Potential For Measurements In Man.

    Science.gov (United States)

    Kilpatrick, Walker D.

    1984-10-01

    Fibre optic laser Doppler anemometry (FOLDA) is a useful technique for in vitro studies but has yet to be used successfully for the measurement of intravascular velocity in man. Some reasons for this are: 1. The difficulty of locating the position of the fibre within the vessel. 2. Lack of knowledge of the precise velocity profile across the vessel. 3. The effects of flow perturbation at the tip of the probe. These problems have been assessed using a FOLDA system developed in our laboratory. Three dimensional velocity profiles of blood flowing in arteries with and without stenoses have been plotted at different rates of flow. The results show that the parabolic profile of fully developed laminar flow is flattened in an arterial stenosis and the degree of flattening increases as flow increases. This means the relationship of the flow and velocity is nonlinear. Any use of FOLDA to assess vessel dimension must take this into account. The position of the fibre in the vessel can only be adequately controlled in in-vitro studies. The region of measurement is only 50 μm diameter and must be at the position of the peak velocity to enable quantitative measurement. Thus the technique is useful in humans only when there is a flat velocity profile such as in the coronary sinus. The relationship between coronary sinus flow and FOLDA velocity is linear in experimental animals. The current FOLDA system has a limited range of projection into the blood stream. The velocity is not linearly related to blood flow when the direction of flow is the same as the projected light, probably due to flow perturbation at the fibre tip. This means that a probe introduced into a coronary artey would not measure linear flow however a probe introduced against the flow could be used to assess the severity of peripheral arterial stenoses. To measure flow across a stenoses before and after angioplasty is possible but requires a method of obtaining an average spatial velocity before it is practicable.

  8. Sub-micrometre accurate free-form optics by three-dimensional printing on single-mode fibres.

    Science.gov (United States)

    Gissibl, Timo; Thiele, Simon; Herkommer, Alois; Giessen, Harald

    2016-06-24

    Micro-optics are widely used in numerous applications, such as beam shaping, collimation, focusing and imaging. We use femtosecond 3D printing to manufacture free-form micro-optical elements. Our method gives sub-micrometre accuracy so that direct manufacturing even on single-mode fibres is possible. We demonstrate the potential of our method by writing different collimation optics, toric lenses, free-form surfaces with polynomials of up to 10th order for intensity beam shaping, as well as chiral photonic crystals for circular polarization filtering, all aligned onto the core of the single-mode fibres. We determine the accuracy of our optics by analysing the output patterns as well as interferometrically characterizing the surfaces. We find excellent agreement with numerical calculations. 3D printing of microoptics can achieve sufficient performance that will allow for rapid prototyping and production of beam-shaping and imaging devices.

  9. Sub-micrometre accurate free-form optics by three-dimensional printing on single-mode fibres

    Science.gov (United States)

    Gissibl, Timo; Thiele, Simon; Herkommer, Alois; Giessen, Harald

    2016-06-01

    Micro-optics are widely used in numerous applications, such as beam shaping, collimation, focusing and imaging. We use femtosecond 3D printing to manufacture free-form micro-optical elements. Our method gives sub-micrometre accuracy so that direct manufacturing even on single-mode fibres is possible. We demonstrate the potential of our method by writing different collimation optics, toric lenses, free-form surfaces with polynomials of up to 10th order for intensity beam shaping, as well as chiral photonic crystals for circular polarization filtering, all aligned onto the core of the single-mode fibres. We determine the accuracy of our optics by analysing the output patterns as well as interferometrically characterizing the surfaces. We find excellent agreement with numerical calculations. 3D printing of microoptics can achieve sufficient performance that will allow for rapid prototyping and production of beam-shaping and imaging devices.

  10. Fibre Optic Sensors for Structural Health Monitoring of Aircraft Composite Structures: Recent Advances and Applications

    Directory of Open Access Journals (Sweden)

    Raffaella Di Sante

    2015-07-01

    Full Text Available In-service structural health monitoring of composite aircraft structures plays a key role in the assessment of their performance and integrity. In recent years, Fibre Optic Sensors (FOS have proved to be a potentially excellent technique for real-time in-situ monitoring of these structures due to their numerous advantages, such as immunity to electromagnetic interference, small size, light weight, durability, and high bandwidth, which allows a great number of sensors to operate in the same system, and the possibility to be integrated within the material. However, more effort is still needed to bring the technology to a fully mature readiness level. In this paper, recent research and applications in structural health monitoring of composite aircraft structures using FOS have been critically reviewed, considering both the multi-point and distributed sensing techniques.

  11. A Sagnac-Michelson fibre optic interferometer: Signal processing for disturbance localization

    Science.gov (United States)

    Kondrat, M.; Szustakowski, M.; Pałka, N.; Ciurapiński, W.; Życzkowski, M.

    2007-09-01

    We present numerical and experimental results on a new generation fibre optic perimeter sensor based on a Sagnac and Michelson interferometers configuration. In particular, an original signal processing scheme is presented. The sensor can detect a potential intruder and determine its position along a protected zone. We propose a localization method that offers the inherent properties of both interferometers. After demodulation of the signals from both interferometers, the obtained amplitude characteristic of the Sagnac interferometer depends on a position of a disturbance along the interferometer, while amplitude characteristic of the Michelson interferometer does not depend on this position. So, quotient of both demodulated characteristics makes it possible to localize the disturbance. During investigations of a laboratory model of the sensor, it was possible to detect the position of the disturbance with a resolution of about 40 m along the 6-km-long sensor.

  12. Implementing optical fibres for the structural health monitoring of composite patch repaired structures

    DEFF Research Database (Denmark)

    Karatzas, Vasileios; Kotsidis, Elias A.; Tsouvalis, Nicholas G.

    2017-01-01

    are reflected to the recorded strain measurements, finite element models have been generated. Results indicate that composite patch repairing drastically increased the load bearing capacity of the plates and that optical fibres constitute an appealing health monitoring system for such applications, being able......Structural health monitoring is increasingly being implemented to improve the level of safety of structures and to reduce inspection and repair costs by allowing for correct planning of these actions, if needed. Composite patch repairing presents an appealing alternative to traditional repair...... methods as it enables the reduction of closedown time and the mitigation of complications associated with traditional repair methods. As reinforcement with the use of composite patches is predominantly performed at defected structures, the urge to monitor the performance of the repair becomes even greater...

  13. Review of Trackside Monitoring Solutions: From Strain Gages to Optical Fibre Sensors

    Directory of Open Access Journals (Sweden)

    Georges Kouroussis

    2015-08-01

    Full Text Available A review of recent research on structural monitoring in railway industry is proposed in this paper, with a special focus on stress-based solutions. After a brief analysis of the mechanical behaviour of ballasted railway tracks, an overview of the most common monitoring techniques is presented. A special attention is paid on strain gages and accelerometers for which the accurate mounting position on the track is requisite. These types of solution are then compared to another modern approach based on the use of optical fibres. Besides, an in-depth discussion is made on the evolution of numerical models that investigate the interaction between railway vehicles and tracks. These models are used to validate experimental devices and to predict the best location(s of the sensors. It is hoped that this review article will stimulate further research activities in this continuously expanding field.

  14. Fibre Optic Sensors for Structural Health Monitoring of Aircraft Composite Structures: Recent Advances and Applications.

    Science.gov (United States)

    Di Sante, Raffaella

    2015-07-30

    In-service structural health monitoring of composite aircraft structures plays a key role in the assessment of their performance and integrity. In recent years, Fibre Optic Sensors (FOS) have proved to be a potentially excellent technique for real-time in-situ monitoring of these structures due to their numerous advantages, such as immunity to electromagnetic interference, small size, light weight, durability, and high bandwidth, which allows a great number of sensors to operate in the same system, and the possibility to be integrated within the material. However, more effort is still needed to bring the technology to a fully mature readiness level. In this paper, recent research and applications in structural health monitoring of composite aircraft structures using FOS have been critically reviewed, considering both the multi-point and distributed sensing techniques.

  15. A tiled CCD detector with 2x2 array and tapered fibre optics for electron microscopy

    CERN Document Server

    Faruqi, A R; Cattermole, D M; Stubbings, S

    2002-01-01

    Charge coupled devices (CCD)-based detectors have made a major impact on data collection in electron microscopy over the past few years. There have been a number of successful applications of CCDs in electron crystallography of two-dimensional protein crystal arrays but high-resolution imaging has been hampered by the relatively poor spatial resolution (and fewer independent pixels) compared to film. A partial solution to this problem, presented in this paper, are to design detectors with larger effective pixel sizes and with more pixels. A CCD detector with a much greater number of 'independent' pixels, achieved by tiling a 2x2 array of CCDs, each of which has 1242x1152 pixels is described here. The sensitive area of the detector, using fibre optics with a demagnification of 2.5 : 1, is 140x130 mm sup 2; the pixel size is 56 mu m square and there is a total of approx 2500x2300 pixels.

  16. A compact and low-loss 1×8 optical power splitter using silica-based PLC on quartz substrate

    Science.gov (United States)

    Wang, Liangliang; An, Junming; Wu, Yuanda; Zhang, Jiashun; Wang, Yue; Li, Jianguang; Wang, Hongjie; Zhang, Xiaoguang; Pan, Pan; Zhang, Liyao; Dai, Hongqing; Liu, Ruidan; Zhong, Fei; Zha, Qiang; Hu, Xiongwei; Zhao, Degang

    2014-02-01

    In this paper, a compact, low-loss and good-uniformity 1×8 optical power splitter with new Y-branch structure is demonstrated using silica-based PLC technology on quartz substrate. Broadening waveguide and transition waveguide of the new Y-branch are optimized by using 3D BPM. The measurement results show that the insertion loss (IL) and the uniformity (UNIF) of the splitters are less than 9.5 dB and 0.35 dB, respectively, in the wavelength range from 1.26 μm to 1.65 μm, and the total product ratio of premium grade in a whole 6 in. wafer is more than 95%. The results mean that our technology completely satisfies the need of mass manufacture.

  17. Correlation of optic neuritis and retinal nerve fibre thickness using optical coherence tomography in a cohort of multiple sclerosis patients

    Directory of Open Access Journals (Sweden)

    Izanne Roos

    2016-03-01

    Full Text Available Background: Optical coherence tomography (OCT is a fast, non-invasive imaging technology that produces 3D, high-resolution images of the retina. Direct visualisation of the retina allows a unique opportunity to study the effects of multiple sclerosis (MS-associated neurodegeneration on retinal ganglion cells as well as effects of retrobulbar demyelination on axonal and retinal architecture through measurement of retinal nerve fibre layer (RNFL thickness and total macular volume (TMV. These findings are clinically important as axonal loss is irreversible and correlates with disability.Aim: To determine the role and usefulness of OCT in a local cohort of MS patients.Setting: Neurology Clinic, Inkosi Albert Luthuli Central Hospital, KwaZulu-Natal, South Africa.Methods: Nineteen patients with MS currently being treated with interferon β-1b underwent OCT examination of both eyes. RNFL thickness and macular volume were measured and correlated with clinical disease characteristics, history of optic neuritis and level of disability.Results: Mean RNFL thickness was 77.3 μm with no significant difference in mean RNFL in eyes with a history of optic neuritis (ON and those without (p = 0.4. Eyes with a history of ON did, however, have significantly thinner RNFL compared with the contralateral eye (p = 0.04. Despite a strong correlation between TMV and RNFL (p = 0.001, a subset of patients with normal RNFL had TMV that was less than 1% of what was expected. There was no correlation between RNFL and disability scores.Conclusion: OCT enables a direct axonal ‘optical biopsy’, for monitoring disease progression and treatment response in MS. RNFL thinning occurs independently of a history of optic neuritis and may represent a chronic optic neuropathy in patients with MS.Keywords: Multiple sclerosis; optical coherence tomography

  18. Estimation of skin phototypes with optical parameters: an experimental study using newly developed fibre optic detection device.

    Science.gov (United States)

    Ries, F; Kapoustina, V; Kron, A; Fink, A; Rädle, M

    2013-02-01

    In an experimental study (October 2010 Mannheim Germany) with 99 Caucasian volunteers, the skin colour (L*, a*, b*) and the reflectance spectra of human skin were compared to the Fitzpatrick's sun-reactive skin photo types (SPT). For this purpose, the skin colour and the reflectance spectra of human skin were determined using non-invasive method with a newly developed fibre optic detection device. The device, based on reflectance spectroscopy, was designed and optimized using a commercial optical analysis Software. By means of the measured spectra of scattered light, the colour values and the absorption spectra of the skin were calculated. Neither any of the L*, a*, b* colour values nor any of the parameters of the absorbance spectra can be used alone to assess the skin type properly. Therefore, an ordinal logistic regression analysis was performed, using the statistical computing software r, to correlate the skin types with the measured optical parameters. It turned out that the detection device combined with the extended statistical analysis gives a better estimate of skin type in respect of the measured optical parameters than a procedure with only L*, a*, b* colour values. Even with the extended methodology, the procedure gives only a rough estimation of the skin type.

  19. Development of Diamond-like Carbon Fibre Wheel

    Institute of Scientific and Technical Information of China (English)

    魏源迁; 山口勝美; 洞口巌; 竹内雅之

    2004-01-01

    A unique diamond-like carbon (DLC) grinding wheel was developed, in which the DLC fibres were made by rolling Al sheets coated with DLC films and aligned normally to the grinding wheel surface by laminating Al sheets together with DLC fibres. In this paper, the formation process of DLC fibres and the fabrication process of a DLC fibre wheel were investigated. Many grinding experiments were also carried out on a precision NC plane milling machine using a newly developed DLC wheel. Grinding of specimens of silicon wafers, optical glasses, quartz, granites and hardened die steel SKD11 demonstrated the capabilities of nanometer surface finish. A smooth surface with a roughness value of Ra2.5nm (Ry26nm) was achieved.

  20. A robust fibre laser system for electro-optic electron bunch profile measurements at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Wissmann, Laurens-Georg

    2012-08-15

    For the electro-optic measurement of electron bunch profiles at FLASH a robust ytterbium doped fibre laser (YDFL) system has been developed consisting of a laser oscillator and a two-staged amplifier. The oscillator is designed to meet the specifications of high reliability and low noise operation. The amplifier makes use of tailored nonlinearity to enhance the spectral bandwidth of the output laser pulses. Active repetition rate control enables sub-picosecond synchronisation of the laser to the accelerator reference RF. Using a two-stage gating scheme the output pulse train repetition rate is adopted to the accelerator repetition rate. An experimental site used for electro-optic electron bunch diagnostics has been redesigned to support single-shot bunch profile measurements based on spectral decoding. An existing bunch profile monitor with a similar laser system was upgraded and electro-optic bunch profile measurements were conducted, allowing for a comparison with measurements done with other longitudinal electron bunch diagnostics and with former measurements.

  1. Moiré Fibre Bragg Grating Written on Strained Fibres

    Institute of Scientific and Technical Information of China (English)

    孙磊; 冯新焕; 刘艳格; 张伟刚; 袁树忠; 开桂云; 董孝义

    2004-01-01

    Moiré fibre Bragg gratings are made in a single mode fibre and a polarization-maintaining fibre respectively, using an excimer KrF laser and a phase mask. Two gratings are written at the same location of the optical fibre. The wavelength spacing can be finely tuned from 0 to 1.86nm by straining the optical fibre during UV illumination.

  2. An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence from quartz inclusions in bricks

    DEFF Research Database (Denmark)

    Ramzaev, V.; Bøtter-Jensen, Lars; Thomsen, Kristina Jørkov

    2008-01-01

    Optically stimulated luminescence (OSL) has been used for estimation of the accumulated doses in quartz inclusions obtained from two fired bricks, extracted in July 2004 from a building located in the forested surroundings of the recreational area Novie Bobovichi, the Bryansk Region, Russia...

  3. Comparative study of the retinal nerve fibre layer thickness performed with optical coherence tomography and GDx scanning laser polarimetry in patients with primary open-angle glaucoma.

    Science.gov (United States)

    Wasyluk, Jaromir T; Jankowska-Lech, Irmina; Terelak-Borys, Barbara; Grabska-Liberek, Iwona

    2012-03-01

    We compared the parameters of retinal nerve fibre layer in patients with advanced glaucoma with the use of different OCT (Optical Coherence Tomograph) devices in relation to analogical measurements performed with GDx VCC (Nerve Fiber Analyzer with Variable Corneal Compensation) scanning laser polarimetry. Study subjects had advanced primary open-angle glaucoma, previously treated conservatively, diagnosed and confirmed by additional examinations (visual field, ophthalmoscopy of optic nerve, gonioscopy), A total of 10 patients were enrolled (9 women and 1 man), aged 18-70 years of age. Nineteen eyes with advanced glaucomatous neuropathy were examined. 1) Performing a threshold perimetry Octopus, G2 strategy and ophthalmoscopy of optic nerve to confirm the presence of advanced primary open-angle glaucoma; 2) performing a GDx VCC scanning laser polarimetry of retinal nerve fibre layer; 3) measuring the retinal nerve fibre layer thickness with 3 different optical coherence tomographs. The parameters of the retinal nerve fibre layer thickness are highly correlated between the GDx and OCT Stratus and 3D OCT-1000 devices in mean retinal nerve fibre layer thickness, retinal nerve fibre layer thickness in the upper sector, and correlation of NFI (GDx) with mean retinal nerve fibre layer thickness in OCT examinations. Absolute values of the retinal nerve fibre layer thickness (measured in µm) differ significantly between GDx and all OCT devices. Examination with OCT devices is a sensitive diagnostic method of glaucoma, with good correlation with the results of GDx scanning laser polarimetry of the patients.

  4. Efficient optical pumping and high optical depth in a hollow-core photonic-crystal fibre for a broadband quantum memory

    CERN Document Server

    Sprague, Michael R; Abdolvand, Amir; Nunn, Joshua; Jin, Xian-Min; Kolthammer, W Steven; Barbieri, Marco; Rigal, Bruno; Michelberger, Patrick S; Champion, Tessa F M; Russell, Philip St J; Walmsley, Ian A

    2012-01-01

    The generation of large multiphoton quantum states - for applications in computing, metrology, and simulation - requires a network of high-efficiency quantum memories capable of storing broadband pulses. Integrating these memories into a fibre offers a number of advantages towards realising this goal: strong light-matter coupling at low powers, simplified alignment, and compatibility with existing photonic architectures. Here, we introduce a large-core kagome-structured hollow-core fibre as a suitable platform for an integrated fibre-based quantum memory with a warm atomic vapour. We demonstrate, for the first time, efficient optical pumping in a hollow-core photonic-crystal fibre with a warm atomic vapour, where (90 $\\pm$ 1)% of atoms are prepared in the ground state. We measure high optical depths (3$\\times 10^{4}$) and, also, narrow homogeneous linewidths that do not exhibit significant transit-time broadening. Our results establish that kagome fibres are suitable for implementing a broadband, room-tempera...

  5. Evanescent optical trapping of nanoscale particles using slotted tapered optical fibres

    CERN Document Server

    Daly, Mark; Chormaic, Síle Nic

    2016-01-01

    While conventional optical trapping techniques can trap objects with submicron dimensions, the underlying limits imposed by the diffraction of light generally restrict their use to larger, or higher refractive index particles. As the index and diameter decrease, the trapping difficulty rapidly increases; hence, the power requirements for stable trapping become so large as to quickly denature the trapped objects in such diffraction-limited systems. Here, we present an evanescent field-based device capable of confining low index nanoscale particles using modest optical powers as low as 1.2 mW, with additional applications in the field of cold atom trapping. Our experiment uses a nanostructured optical micro-nanofibre to trap 200 nm, low-index, fluorescent particles within the structured region, thereby overcoming diffraction limitations. We analyse the trapping potential of this device both experimentally and theoretically, and show how strong optical traps are achieved with low input powers.

  6. BRIEF COMMUNICATIONS: Influence of γ irradiation on the temperature dependence of the optical losses in quartz glass-polymer fiber waveguides

    Science.gov (United States)

    Andreev, A. Ts; Borkina, G. Yu; Bubnov, M. M.; Voĭtsekhovskiĭ, V. V.; Dianov, Evgenii M.; Kotov, V. M.; Pryakhina, Tatiana A.

    1981-08-01

    A study was made of the influence of γ irradiation on the temperature dependences of the optical losses in quartz glass-polymer fiber waveguides. The working temperature range was extended by γ irradiation to subzero temperatures in the case of two types of waveguide: those with a cladding made of SIÉL commercial silicone rubber and those made by the Quartz-Silice firm. The results obtained were explained by changes in the structure of silicone rubber under the action of γ irradiation.

  7. Large nonlinear optical response of polycrystalline Bi3.25La0.75Ti3O12 ferroelectric thin films on quartz substrates.

    Science.gov (United States)

    Shin, Heedeuk; Chang, Hye Jeong; Boyd, Robert W; Choi, M R; Jo, W

    2007-08-15

    We measure the nonlinear susceptibility of Bi(3.25)La(0.75)Ti(3)O(12) (BLT) thin films grown on quartz substrates using the Z-scan technique with picosecond laser pulses at a wavelength of 532 nm. The third-order nonlinear refractive index coefficient gamma and absorption coefficient beta of the BLT thin film are 3.1 x 10(-10) cm(2)/W and 3 x 10(-5) cm/W, respectively, which are much larger than those of most ferroelectric films. The results show that the BLT thin films on quartz substrates are good candidate materials for applications in nonlinear optical devices.

  8. Sub-aquatic response of a scintillator, fibre optic and silicon photomultiplier based radiation sensor

    Science.gov (United States)

    Jackson, Sarah F.; Monk, Stephen D.; Stanley, Steven J.; Lennox, Kathryn

    2014-07-01

    We describe an attempt at the utilisation of two low level light sensors to improve on the design of a dose monitoring system, specifically for underwater applications with consideration for the effects of water attenuation. The gamma radiation ‘RadLine®’ detector consists of an inorganic scintillating crystal coupled to a fibre optic cable which transports scintillation photons, up to hundreds of metres, to an optical sensor. Analysed here are two contemporary technologies; SensL's MiniSL a silicon photomultiplier (SiPM) and a Sens-Tech photon counting photomultiplier tube (PMT). A clinical radiotherapy linear accelerator (linac) is implemented as test beam, subjecting the RadLine® to a highly controlled dose rate (ranging from 0 Sv h-1 to 320 Sv h-1), averaging at 2 MeV in energy. The RadLine's underwater dose monitoring capabilities are tested with the aid of epoxy resin ‘solid water’ phantom blocks, used as a substitute for water. Our results show that the MiniSL SiPM is unsuitable for this application due to extremely high background noise levels, however the Sens-Tech PMT performs satisfactorily and the detected dose rate due to the effects of water attenuation compares strongly with MCNP simulation data and NIST database values. We conclude that the PMT shows promise for its ultimate use in the First Generation Magnox Storage Pond (FGMSP) on the Sellafield site.

  9. Fibre Optic Bus Network For Voice And Data Transmission In A Ship

    Science.gov (United States)

    Jhunjhunwala, Ashok; Sanghi, R. K.; Manjunath, D.

    1987-12-01

    A versatile communication system in a ship with 120 stations, each having voice and data transmission is envisaged. The proposed fibre optic network has a bus topology ideally suited for distribution in ship-like environment. Use has been made of standard ETHERNET chip sets manufactured by INTEL. This makes the stations compact, easier to maintain and inexpensive. The ETHERNET proto-col is primarily designed for packet data transmission. The collision detection and backoff protocol makes the packet transmission probabilistic and is therefore not suitable for voice transmission. This problem is overcome in the present design by a scheme where the required number of voice slots are dynamically allocated. That is, having established a connection for voice communication between stations, fixed slots are assigned for voice transmission and reception. The data transmission continues to use CSMA/CD Protocol. A simple hardware addition to the ETHERNET chip set makes the scheme workable. Drops in the fiber optic bus network is through passive star couplers. Four to eight star couplers are used in the present scheme with repeaters between adjacent star couplers. The repeaters will not be usual repeaters, as ordinary repeaters would cause loops to be formed between adjacent stars, thereby causing data to recirculate. This recirculation is avoided by making the repeater intelligent and also performing the task of detecting collisions between signals originating from stations connected to different star couplers.

  10. Multi-fibre optical spectroscopy of low-mass stars and brown dwarfs in Upper Sco

    CERN Document Server

    Lodieu, N; Hambly, N C

    2011-01-01

    We have obtained multi-fibre intermediate-resolution optical spectroscopy of 94 photometric and proper motion selected low-mass star and brown dwarf candidates in Upper Sco with AAT/AAOmega. We have estimated the spectral types and measured the equivalent widths of youth and gravity diagnostic features to confirm the spectroscopic membership of about 95% of the candidates extracted from 6.5 square degrees in Upper Sco. We also detect lithium in the spectra with the highest signal-to-noise, consolidating our conclusions about their youth. Furthermore, we derive an estimate of our selections using spectroscopic data obtained for a large number of stars falling into the instrument's field-of-view. We have estimated the effective temperatures and masses for each new spectroscopic member using the latest evolutionary models available for low-mass stars and brown dwarfs. Combining the current optical spectroscopy presented here with near-infrared spectroscopy obtained for the faintest photometric candidates, we con...

  11. Design and characterisation of a real time proton and carbon ion radiography system based on scintillating optical fibres.

    Science.gov (United States)

    Lo Presti, D; Bonanno, D L; Longhitano, F; Bongiovanni, D G; Russo, G V; Leonora, E; Randazzo, N; Reito, S; Sipala, V; Gallo, G

    2016-09-01

    This paper describes the design and characterization of a charged particle imaging system composed of a position sensitive detector and residual range detector. The position detector consists of two identical overlying and orthogonal planes each of which consists of two layers of pre-aligned and juxtaposed scintillating fibres. The 500μm square section fibres are optically coupled to two Silicon Photomultiplier arrays using a channel reduction system patented by the Istituto Nazionale di Fisica Nucleare. The residual range detector consists of sixty parallel layers of the same fibres used in the position detector each of which is optically coupled to a Silicon Photomultiplier array by wavelength shifting fibres. The sensitive area of the two detectors is 9×9cm(2). Characterising the position sensitive and the residual range detectors to reconstruct the radiography, is fundamental to validating the detectors' designs. The proton radiography of a calibrated target in imaging conditions is presented. The spatial resolution of the position sensitive detector is about 150μm and the range resolution is about 170μm. The performance of the prototypes were tested at CATANA proton therapy facility (Laboratori Nazionali del Sud, INFN, Catania) with energy up to 58MeV and rate of about 10(6) particles per second. The comparison between the simulations and measurements confirms the validity of this system. Copyright © 2016 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  12. Impact of amplitude jitter and signal-to-noise ratio on the nonlinear spectral compression in optical fibres

    Science.gov (United States)

    Boscolo, Sonia; Fatome, Julien; Finot, Christophe

    2017-04-01

    We numerically study the effects of amplitude fluctuations and signal-to-noise ratio degradation of the seed pulses on the spectral compression process arising from nonlinear propagation in an optical fibre. The unveiled quite good stability of the process against these pulse degradation factors is assessed in the context of optical regeneration of intensity-modulated signals, by combining nonlinear spectral compression with centered bandpass optical filtering. The results show that the proposed nonlinear processing scheme indeed achieves mitigation of the signal's amplitude noise. However, in the presence of a jitter of the temporal duration of the pulses, the performance of the device deteriorates. © 2016 Elsevier

  13. Fibre optics wavemeters calibration using a self-referenced optical frequency comb

    Science.gov (United States)

    Galindo-Santos, J.; Velasco, A. V.; Corredera, P.

    2015-01-01

    Self-referenced optical frequency combs enable the measurement of optical frequencies with a very high accuracy, achieving uncertainties close to the atomic clock used as reference (CSIC and its application to the calibration of two wavemeters in the 1.5 μm optical communication window. Calibration uncertainties down to 12 MHz and 59 MHz were obtained, respectively, for each of the devices. Furthermore, the long-term behaviour of the higher resolution wavemeter was studied during a 750 h period of sustained operation, exhibiting a dispersion in the measurements of 7.72 MHz. Temperature dependence of the device was analysed, enabling to further reduce dispersion down to a 2.15 MHz range, with no significant temporal deviations.

  14. Efficient optical pumping and high optical depth in a hollow-core photonic-crystal fibre for a broadband quantum memory

    Science.gov (United States)

    Sprague, Michael R.; England, Duncan G.; Abdolvand, Amir; Nunn, Joshua; Jin, Xian-Min; Kolthammer, W. Steven; Barbieri, Marco; Rigal, Bruno; Michelberger, Patrick S.; Champion, Tessa F. M.; Russell, Philip St. J.; Walmsley, Ian A.

    2013-05-01

    The generation of large multiphoton quantum states—for applications in computing, metrology and simulation—requires a network of high-efficiency quantum memories capable of storing broadband pulses. Integrating these memories into a fibre offers a number of advantages towards realizing this goal: strong light-matter coupling at low powers, simplified alignment and compatibility with existing photonic architectures. Here, we introduce a large-core kagome-structured hollow-core fibre as a suitable platform for an integrated fibre-based quantum memory with a warm atomic vapour. We demonstrate, for the first time, efficient optical pumping in such a system, where 90 ± 1% of atoms are prepared in the ground state. We measure high optical depths (3 × 104) and narrow homogeneous linewidths (6 ± 2 MHz) that do not exhibit significant transit-time broadening, showing that we can prepare a Λ-level system in a pure state. Our results establish that kagome fibres are suitable for implementing a broadband, room-temperature quantum memory, as well as a range of nonlinear optical effects.

  15. Evaluation of MidIR fibre optic reflectance: detection limit, reproducibility and binary mixture discrimination.

    Science.gov (United States)

    Sessa, Clarimma; Bagán, Héctor; García, José Francisco

    2013-11-01

    MidIR fibre optic reflectance (MidIR-FORS) is a promising analytical technique in the field of science conservation, especially because it is non-destructive. Another advantage of MidIR-FORS is that the obtained information is representative, as a large amount of spectral data can be collected. Although the technique has a high potential and is almost routinely applied, its quality parameters have not been thoroughly studied in the specific application of analysis of artistic materials. The objective of this study is to evaluate the instrumental capabilities of MidIR-FORS for the analysis of artwork materials in terms of detection limit, reproducibility, and mixture characterisation. The study has been focused on oil easel painting and several paints of known composition have been analysed. Paint layers include blue pigments not only because of their important role along art history, but also because their physical and spectroscopic characteristics allow a better evaluation of the MidIR-FORS capabilities. The results of the analysis indicate that MidIR-FORS supplies a signal affected by different factors, such as the optical, morphological and physical properties of the surface, in addition to the composition of materials analysed. Consequently, the detection limits established are relatively high for artistic objects (Prussian blue - PB 2.1-6.5%; Phthalocyanine blue - Pht 6.3-10.2%; synthetic Ultramarine blue - UM 12.1%) and may therefore lead to an incomplete description of the artwork. Reproducibility of the technique over time and across surface has been determined. The results show that the major sources of dispersion are the heterogeneity of the pigments distribution, physical features, and band shape distortions. The total dispersion is around 4% for the most intense bands (oil) and increases up to 26% when weak or overlapped bands are considered (PB, Pht, UM). The application of different pre-treatments (cutoff of fibres absorption, Savizky-Golay smoothing

  16. Introduction of fibre-optic technology in an opencast lignite mine; Einfuehrung von LWL-Technik in einem Braunkohlentagebau

    Energy Technology Data Exchange (ETDEWEB)

    Paus, K.H. [RWE Power AG, Ressort Braunkohlenbergbau/Veredlung, Technikzentrum Tagebaue/HW, Elektrotechnik und technische Vergabe PDV, Kommunikationsanlagen (PBZ-KK), Frechen (Germany); Hehlert, H.A. [RWE Power AG, Ressort Braunkohlenbergbau/Veredlung, Technikzentrum Tagebaue/HW, Elektrotechnik und technische Vergabe Foerderanlagen (PBZ-KP), Frechen (Germany); Andres, M. [RWE Power AG, Ressort Braunkohlenbergbau/Veredlung, Tagebau Hambach, Infrastruktur Prozessdatenverarbeitung (PBH-IP), Niederzier (Germany)

    2006-06-15

    The introduction of fibre-optic technology for the communications infrastructure in our opencast mines entailed the envisaged improvements in automation and operations management. A motivated project team prepared to face new technologies, adopt and use them in day-to-day operations and optimize them has helped sensitive fibre-optic technology to stand the 'acid test' of opencast mine operations. The concepts and operating equipment developed within the scope of the pilot project in the Hambach mine have meanwhile become a standard applied in all RWE Power mines. The whole Garzweiler II mine, for example, has been erected on the basis of these standards. And the upcoming new installation of the belt conveyors in the Inden II mine will be executed in line with these standards as well. (orig.)

  17. Megavoltage X-Ray Imaging Based on Cerenkov Effect: A New Application of Optical Fibres to Radiation Therapy

    Directory of Open Access Journals (Sweden)

    A. Teymurazyan

    2012-01-01

    Full Text Available A Monte Carlo simulation was used to study imaging and dosimetric characteristics of a novel design of megavoltage (MV X-ray detectors for radiotherapy applications. The new design uses Cerenkov effect to convert X-ray energy absorbed in optical fibres into light for MV X-ray imaging. The proposed detector consists of a matrix of optical fibres aligned with the incident X rays and coupled to an active matrix flat-panel imager (AMFPI for image readout. Properties, such as modulation transfer function, detection quantum efficiency (DQE, and energy response of the detector, were investigated. It has been shown that the proposed detector can have a zero-frequency DQE more than an order of magnitude higher than that of current electronic portal imaging device (EPID systems and yet a spatial resolution comparable to that of video-based EPIDs. The proposed detector is also less sensitive to scattered X rays from patients than current EPIDs.

  18. Saturation Effect on Pump-to-Signal Intensity Modulation Transfer in Single-Pump Phase-Insensitive Fibre Optic Parametric Amplifiers

    DEFF Research Database (Denmark)

    Cristofori, Valentina; Lali-Dastjerdi, Zohreh; Lund-Hansen, Toke

    2011-01-01

    A numerical and experimental characterization of how signal gain saturation affects the transfer of the intensity modulation of the pump to the signal in single-pump phaseinsensitive fibre optic parametric amplifiers is presented.......A numerical and experimental characterization of how signal gain saturation affects the transfer of the intensity modulation of the pump to the signal in single-pump phaseinsensitive fibre optic parametric amplifiers is presented....

  19. Determination of the percentage of milk (cow's, ewe's and goat's) in cheeses with different ripening times using near infrared spectroscopy technology and a remote reflectance fibre-optic probe.

    Science.gov (United States)

    González-Martín, I; Hernández-Hierro, J M; Morón-Sancho, R; Salvador-Esteban, J; Vivar-Quintana, A; Revilla, I

    2007-12-05

    In the present work we studied the use of near infrared spectroscopy (NIRS) technology employing a remote reflectance fibre-optic probe (with a 5 cm x 5 cm quartz window) for the analysis of the percentage of milk (cow's, ewe's and goat's) used in the elaboration of cheeses with different ripening times. To do so, cheeses with known and varying percentages of cow's, ewe's and goat's milk were elaborated (112 samples with milk collected in winter and 112 samples with milk collected in summer) and used as reference material, and ripening controls were performed over 6 months. The method allows immediate control of the cheese without prior sample treatment or destruction by direct application of the fibre-optic probe to the sample. The regression method employed was modified partial least squares (MPLS). Of all the samples (224), 200 formed to so-called calibration set and the other 24 were used for external validation. The calibration results obtained using 200 samples of cheese allowed the percentage of cow's, ewe's and goat's milk to be measured. The multiple correlation coefficients (RSQ) and prediction corrected standard errors (SEP(C)) obtained were respectively, 0.834 and 11.6% for cow's milk; 0.871 and 9.8% for goat's milk; 0.880 and 10.6% for ewe's milk. The ratio performance deviation (RPD) values obtained indicate that the NIRS equations can be applied to unknown samples.

  20. Fibre illumination system

    DEFF Research Database (Denmark)

    2012-01-01

    Source: EP2426402A The invention relates to a fibre illumination module and system for the collection and delivery of daylight for illumination purposes. The fibre illumination module comprises a plurality of collector elements, each collector element comprising an input fibre having a first end...... the proximal end of the collection optics into the first end of the input fibre, each collector element having a principal axis for the collection of light defining an optical axis of the collector element. The optical axes of the collector elements are arranged in a radially outward pointing multi...