WorldWideScience

Sample records for quartz crystal impedance

  1. Density-viscosity product of small-volume ionic liquid samples using quartz crystal impedance analysis.

    Science.gov (United States)

    McHale, Glen; Hardacre, Chris; Ge, Rile; Doy, Nicola; Allen, Ray W K; MacInnes, Jordan M; Bown, Mark R; Newton, Michael I

    2008-08-01

    Quartz crystal impedance analysis has been developed as a technique to assess whether room-temperature ionic liquids are Newtonian fluids and as a small-volume method for determining the values of their viscosity-density product, rho eta. Changes in the impedance spectrum of a 5-MHz fundamental frequency quartz crystal induced by a water-miscible room-temperature ionic liquid, 1-butyl-3-methylimiclazolium trifluoromethylsulfonate ([C4mim][OTf]), were measured. From coupled frequency shift and bandwidth changes as the concentration was varied from 0 to 100% ionic liquid, it was determined that this liquid provided a Newtonian response. A second water-immiscible ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide [C4mim][NTf2], with concentration varied using methanol, was tested and also found to provide a Newtonian response. In both cases, the values of the square root of the viscosity-density product deduced from the small-volume quartz crystal technique were consistent with those measured using a viscometer and density meter. The third harmonic of the crystal was found to provide the closest agreement between the two measurement methods; the pure ionic liquids had the largest difference of approximately 10%. In addition, 18 pure ionic liquids were tested, and for 11 of these, good-quality frequency shift and bandwidth data were obtained; these 12 all had a Newtonian response. The frequency shift of the third harmonic was found to vary linearly with square root of viscosity-density product of the pure ionic liquids up to a value of square root(rho eta) approximately 18 kg m(-2) s(-1/2), but with a slope 10% smaller than that predicted by the Kanazawa and Gordon equation. It is envisaged that the quartz crystal technique could be used in a high-throughput microfluidic system for characterizing ionic liquids.

  2. Results from a Novel Method for Corrosion Studies of Electroplated Lithium Metal Based on Measurements with an Impedance Scanning Electrochemical Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Martin Winter

    2013-07-01

    Full Text Available A new approach to study the chemical stability of electrodeposited lithium on a copper metal substrate via measurements with a fast impedance scanning electrochemical quartz crystal microbalance is presented. The corrosion of electrochemically deposited lithium was compared in two different electrolytes, based on lithium difluoro(oxalato borate (LiDFOB and lithium hexafluorophosphate, both salts being dissolved in solvent blends of ethylene carbonate and diethyl carbonate. For a better understanding of the corrosion mechanisms, scanning electron microscopy images of electrodeposited lithium were also consulted. The results of the EQCM experiments were supported by AC impedance measurements and clearly showed two different corrosion mechanisms caused by the different salts and the formed SEIs. The observed mass decrease of the quartz sensor of the LiDFOB-based electrolyte is not smooth, but rather composed of a series of abrupt mass fluctuations in contrast to that of the lithium hexafluorophosphate-based electrolyte. After each slow decrease of mass a rather fast increase of mass is observed several times. The slow mass decrease can be attributed to a consolidation process of the SEI or to the partial dissolution of the SEI leaving finally lithium metal unprotected so that a fast film formation sets in entailing the observed fast mass increases.

  3. Quartz crystal fabrication facility

    Science.gov (United States)

    Ney, R. J.

    1980-05-01

    The report describes the design and operation of a five chamber, interconnected vacuum system, which is capable of cleaning, plating, and sealing precision quartz crystal units in ceramic flatpack enclosures continuously in a high vacuum environment. The production rate design goal was 200 units per eight hour day. A unique nozzle beam gold deposition source was developed to operate for extended periods of time without reloading. The source puts out a narrow beam of gold typically in the order of 2 1/2 deg included cone angle. Maximum deposition rates are in the order of 400 a/min at 5.5 in. 'throw' distance used. Entrance and exit air lock chambers expedite the material throughput, so that the processing chambers are at high vacuum for extended periods of time. A stainless steel conveyor belt, in conjunction with three vacuum manipulators, transport the resonator components to the various work stations. Individual chambers are normally separated from each other by gate valves. The crystal resonators, mounted in flatpack frames but unplated, are loaded into transport trays in a lid-frame-lid sequency for insertion into the system and exit as completed crystal units. The system utilizes molybdenum coated ball bearings at essentially all friction surfaces. The gold sources and plating mask heads are equipped with elevators and gate valves, so that they can be removed from the system for maintenance without exposing the chambers to atmosphere.

  4. Electrochemical quartz crystal impedance study on immobilization of glucose oxidase in a polymer grown from dopamine oxidation at an Au electrode for glucose sensing

    International Nuclear Information System (INIS)

    Li Mingrui; Deng Chunyan; Xie Qingji; Yang Yang; Yao Shouzhuo

    2006-01-01

    Glucose oxidase (GOD) was codeposited into a polymer grown from oxidation of dopamine (DA) at an Au electrode in a neutral phosphate aqueous solution for the first time. The electrochemical quartz crystal impedance analysis (EQCIA) method was used to monitor the GOD-immobilization process. Effects of concentrations of phosphate buffer, DA and GOD were investigated, and the optimal concentrations were found to be 20.0mM phosphate buffer (pH 7.0), 30.0mM DA and 5.00mgml -1 GOD. A glucose biosensor was thus constructed, and effects of various experimental parameters on the sensor performance, including applied potential, solution pH and electroactive interferents, were examined. At an optimal potential of 0.6V versus the KCl-saturated calomel electrode (SCE), the current response of the biosensor in the selected phosphate buffer (pH 7.0) was linear with the concentration of glucose from 0.05 to 9mM, with a lower detection limit of 3μM (S/N=3), short response time (within 15s) and good anti-interferent ability. The Michaelis constant (K m app ) was estimated to be 9.6mM. The biosensor exhibited good storage stability, i.e. 96% of its initial response was retained after 7-day storage in the selected phosphate buffer at 4deg. C, and even after another 3 weeks the biosensor retained 86% of its initial response. In addition, the enzymatic specific activity and enzymatic relative activity of the GOD immobilized in the polymer from dopamine oxidation (PFDO) were estimated from the EQCIA method to be 1.43kUg -1 and 3.7%, respectively, which were larger than the relevant values obtained experimentally using poly(o-aminophenol) and poly(N-methylpyrrole) matrices, suggesting that the PFDO is a better matrix to immobilize GOD

  5. Quartz substrate infrared photonic crystal

    Science.gov (United States)

    Ghadiri, Khosrow; Rejeb, Jalel; Vitchev, Vladimir N.

    2003-01-01

    This paper presents the fabrication of a planar photonic crystal (p2c) made of a square array of dielectric rods embedded in air, operating in the infrared spectrum. A quartz substrate is employed instead of the commonly used silicon or column III-V substrate. Our square structure has a normalized cylinder radius-to-pitch ratio of r/a = 0.248 and dielectric material contrast ɛr of 4.5. We choose a Z-cut synthetic quartz for its cut (geometry), and etching properties. Then a particular Z-axis etching process is employed in order to ensure the sharp-edged verticality of the rods and fast etching speed. We also present the computer simulations that allowed the establishment of the photonic band gaps (PBG) of our photonic crystal, as well as the actual measurements. An experimental measurement have been carried out and compared with different simulations. It was found that experimental results are in good agreement with different simulation results. Finally, a frequency selective device for optical communication based on the introduction of impurity sites in the photonic crystal is presented. With our proposed structure Optical System on a Chip (OsoC) with micro-cavity based active devices such as lasers, diodes, modulators, couplers, frequency selective emitters, add-drop filters, detectors, mux/demuxes and polarizers connected by passive waveguide links can be realized.

  6. Construction of simple quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Ristov, Milcho [Center of Energy, Informatics and Materials of the Macedonian Academy fo Science and Arts, Skopje (Macedonia, The Former Yugoslav Republic of); Mitrevski, Mitre [Institute of Physics, Faculty of natural Science and Mathematics, Ss Cyril and Methodius University, Skopje (Macedonia, The Former Yugoslav Republic of)

    2003-07-01

    A very simple Quartz Crystal Microbalance (QCM) was constructed for the measurement of thickness of chemically deposited thin films. QCM consisted of two active elements: one dual-gate MOSFET and one bipolar transistor, and as usually two AT-cut quartz crystal. The beat frequency oscillation generated as a result of loading of the sensor crystal by the deposited thin film, was measured by HP-multimeter, set as a low frequency meter. The sensitivity was found to be high and satisfactory for the study of growth rate of thin films, mainly deposited by methods of chemical deposition.

  7. Construction of simple quartz crystal microbalance

    International Nuclear Information System (INIS)

    Ristov, Milcho; Mitrevski, Mitre

    2002-01-01

    A very simple Quartz Crystal Microbalance (QCM) was constructed for the measurement of thickness of chemically deposited thin films. QCM consisted of two active elements: one dual-gate MOSFET and one bipolar transistor, and as usually two AT-cut quartz crystal. The beat frequency oscillation generated as a result of loading of the sensor crystal by the deposited thin film, was measured by HP-multimeter, set as a low frequency meter. The sensitivity was found to be high and satisfactory for the study of growth rate of thin films, mainly deposited by methods of chemical deposition.

  8. Quartz crystal reinforced quartz glass by spark plasma sintering

    International Nuclear Information System (INIS)

    Torikai, D.; Barazani, B.; Ono, E.; Santos, M.F.M.; Suzuki, C.K.

    2011-01-01

    The Spark Plasma Sintering presents fast processing time when compared to conventional sintering techniques. This allows to control the grain growth during sintering as well as the diffusion rate of a multi-material compounds, and make possible obtainment of functionally graded materials and nanostructured compounds. Powders of high purity silica glass and crystalline silica were sintered in a SPS equipment at temperatures around 1350° C, i.e., above the softening temperature of silica glass and below the melting temperature of quartz crystal. As a result, glass ceramics with pure silica glass matrix reinforced with crystalline alpha-quartz grains were fabricated at almost any desired range of composition, as well as controlled size of the crystalline reinforcement. X-ray diffraction and density measurements showed the possibility to manufacture a well controlled density and crystallinity glass-ceramic materials. (author)

  9. Data Acquisition System for Quartz Crystal Microbalances

    Directory of Open Access Journals (Sweden)

    Kleber Romero Felizardo

    2006-02-01

    Full Text Available This work presents a data acquisition system used in a mass sensor: quartz crystal microbalance. This system reads the frequency of this sensor along the time and sends the collected data to the computer through a serial interface.

  10. Historical review of quartz crystal growth

    Science.gov (United States)

    Iwasaki, Fumiko; Iwasaki, Hideo

    2002-04-01

    The history of quartz crystal growth is reviewed from the origin to the industrialization. The developing process of growth techniques is divided into the following three stages: (1) The fundamental work based on the mineralogical genetic view point, which was performed in Italy during the end of the 19th to the beginning of the 20th centuries. (2) The works to attempt the industrial application made in Germany and in England during World War II. (3) The industrialization of quartz growth after World War II. These were initiated in England, in USA and independently in Russia. The highest mass production process was developed in Japan. The historical flow is traced by the interview of several persons based on the original references.

  11. Quartz Crystal Temperature Sensor for MAS NMR

    Science.gov (United States)

    Simon, Gerald

    1997-10-01

    Quartz crystal temperature sensors (QCTS) were tested for the first time as wireless thermometers in NMR MAS rotors utilizing the NMR RF technique itself for exiting and receiving electro-mechanical quartz resonances. This new tool in MAS NMR has a high sensitivity, linearity, and precision. When compared to the frequently used calibration of the variable temperature in the NMR system by a solid state NMR chemical shift thermometer (CST), such as lead nitrate, QCTS shows a number of advantages. It is an inert thermometer in close contact with solid samples operating parallel to the NMR experiment. QCTS can be manufactured for any frequency to be near a NMR frequency of interest (typically 1 to 2 MHz below or above). Due to the strong response of the crystal, signal detection is possible without changing the tuning of the MAS probe. The NMR signal is not influenced due to the relative sharp crystal resonance, restricted excitation by finite pulses, high probeQvalues, and commonly used audio filters. The quadratic dependence of the temperature increase on spinning speed is the same for the QCTS and for the CST lead nitrate and is discussed in terms of frictional heat in accordance with the literature about lead nitrate and with the results of a simple rotor speed jump experiment with differently radial located lead nitrate in the rotor.

  12. Thickness shear mode quartz crystal resonators with optimized elliptical electrodes

    International Nuclear Information System (INIS)

    Ma Ting-Feng; Feng Guan-Ping; Zhang Chao; Jiang Xiao-Ning

    2011-01-01

    Quartz crystal resonators (QCRs) with circular electrodes have been widely used for various liquid and gas sensing applications. In this work, quartz crystal resonators with elliptical electrodes were studied and tested for liquid property measurement. Mindlin's theory was used to optimize the dimension and geometry of the electrodes and a 5-MHz QCR with minimum series resistance and without any spurious modes was obtained. A series of AT-cut QCRs with elliptical electrodes of different sizes were fabricated and their sensing performances were compared to devices with circular electrodes. The experimental result shows that the device with elliptical electrodes can obtain lower resonance impedance and a higher Q factor, which results in a better loading capability. Even though the sensitivities of devices with elliptical and circular electrodes are found to be similar, the sensor with elliptical electrodes has much higher resolution due to a better frequency stability. The study indicates that the performance of QCRs with elliptical electrodes is superior to that of traditional QCRs with circular electrodes. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  13. Mechanical and optical nanodevices in single-crystal quartz

    Science.gov (United States)

    Sohn, Young-Ik; Miller, Rachel; Venkataraman, Vivek; Lončar, Marko

    2017-12-01

    Single-crystal α-quartz, one of the most widely used piezoelectric materials, has enabled a wide range of timing applications. Owing to the fact that an integrated thin-film based quartz platform is not available, most of these applications rely on macroscopic, bulk crystal-based devices. Here, we show that the Faraday cage angled-etching technique can be used to realize nanoscale electromechanical and photonic devices in quartz. Using this approach, we demonstrate quartz nanomechanical cantilevers and ring resonators featuring Qs of 4900 and 8900, respectively.

  14. Positron states and nanoobjects in proton-irradiated quartz single crystals: Positronium atom in quartz

    International Nuclear Information System (INIS)

    Grafutin, V. I.; Zaluzhnyi, A. G.; Timoshenkov, S. P.; Britkov, O. M.; Ilyukhina, O. V.; Myasishcheva, G. G.; Prokop'ev, E. P.; Funtikov, Yu. V.

    2008-01-01

    The influence of proton bombardment and metal atom impurities on the structure of quartz single crystals has been studied. The related defects have been studied using positron annihilation spectroscopy (angular correlation of positron-annihilation photons), acoustic absorption, and optical absorption measurements. It is shown that the presence of a narrow component f in the angular distribution of annihilation photons (ADAP), which is related to the formation of parapositronium, determines a high sensitivity of this method with respect to features of the crystal structure of quartz. It is established that the defectness of the structure of irradiated quartz crystals can be characterized by the ratio f/f 0 of the relative intensities of narrow components in the ADAP curves measured before (f 0 ) and after (f) irradiation. Any process leading to a decrease in the probability of positronium formation (e.g., positron loss as a result of the trapping on defects and the interaction with impurity atoms and lattice distortions) decreases the intensity of the narrow component. Based on the ADAP data, estimates of the radii and concentrations of nanodefects in quartz have been obtained and their variation upon annealing at temperatures up to T = 873 K has been studied

  15. Complex impedance spectroscopy of alkali impurities in as-grown, irradiated and annealed quartz

    International Nuclear Information System (INIS)

    Devautour-Vinot, S.; Cambon, O.; Prud'homme, N.; Giuntini, J. C.; Boy, J.-J.; Cibiel, G.

    2007-01-01

    This work compares the dielectric relaxation properties of different crystalline quartz materials, according to their source (natural or synthetics). It is shown that these relaxation properties are due to a hopping process of alkaline (Li + , Na + , and K + ) impurities located near [Al-O 4 ] 5- tetrahedra. A detailed analysis, in terms of the distribution function of the dielectric loss peak, allowed us to perfectly distinguish the different types of as-grown quartz. We show that (i) the natural quartz has less stable M + charge carriers than the synthetic materials and that (ii) the homogeneity of the M + trapping sites, created by the [Al-O 4 ] 5- tetrahedra, strongly depends on the crystal growth conditions. These features were then studied using quartz samples with different treatment conditions: as-grown, irradiated, or annealed at high temperature. We propose that the irradiation greatly facilitates the M + relaxation, by creating additional low energy M + hosting sites, whose number depends on the source of the quartz crystals. We also show that for 100 krad irradiation, the saturation state of the defects is already reached for all the materials under consideration. Finally, we propose that the irradiation followed by annealing at 450 deg. C improves the M + stability and homogeneity in quartz materials, compared with the as-grown materials, this trend being much more relevant for the natural than for the synthetic quartz

  16. Miniature quartz crystal-resonator-based thermogravimetric detector.

    Science.gov (United States)

    Sai, N; Tagawa, Y; Sohgawa, M; Abe, T

    2014-09-01

    In this work, a new design for a microheater combined with a quartz crystal microbalance (QCM) array for thermogravimetric analysis is presented. Each QCM consists of two electrodes to excite thickness-shear-mode vibrations and one microheater to increase the temperature on the crystal backside. In addition, all the electrode pads are patterned on the crystal backside, making the design of the QCM compact and user-friendly. Finally, the proposed QCM array was employed to separate ethanol from methanol. This was successfully achieved via thermal desorption spectra calculated by differentiating the frequency changes.

  17. The coexistence of pressure waves in the operation of quartz-crystal shear-wave sensors

    OpenAIRE

    Reddy, SM; Jones, JP; Lewis, TJ

    1998-01-01

    It is demonstrated that an AT-cut quartz crystal driven in the thickness-shear-wave mode and typically used as a sensor to monitor the viscoelastic shear-wave properties of a fluid also produce longitudinal pressure waves. Unlike the shear wave, these waves are capable of long-range propagation through the fluid and of reflection at its boundaries, notably at an outer fluid–air interface. They introduce a component into the measured electrical impedance and resonance frequency shift of the cr...

  18. A quartz crystal microbalance dew point sensor without frequency measurement

    Science.gov (United States)

    Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin

    2014-11-01

    This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.

  19. Recent Advances in Quartz Crystal Microbalance-Based Sensors

    Directory of Open Access Journals (Sweden)

    Sandeep Kumar Vashist

    2011-01-01

    Full Text Available Quartz crystal microbalance (QCM has gained exceptional importance in the fields of (biosensors, material science, environmental monitoring, and electrochemistry based on the phenomenal development in QCM-based sensing during the last two decades. This review provides an overview of recent advances made in QCM-based sensors, which have been widely employed in a plethora of applications for the detection of chemicals, biomolecules and microorganisms.

  20. Scratching experiments on quartz crystals: Orientation effects in chipping

    Science.gov (United States)

    Tellier, C. R.; Benmessaouda, D.

    1994-06-01

    The deformation and microfracture properties of quartz crystals were studied by scratching experiments. The critical load at which microfractures are initiated was found to be orientation dependent, whereas the average width of ductile grooves and chips remained relatively insensitive to crystal orientation. In contrast, a marked anisotropy in the shape of chips was observed. This anisotropy has been interpreted in terms of microfractures propagating preferentially along slip planes. Simple geometrical conditions for the SEM (scanning electron microscopy) observation of active slip planes are proposed.

  1. Measuring the diffraction properties of an imaging quartz(211) crystal

    Energy Technology Data Exchange (ETDEWEB)

    Haugh, M. J.; Jacoby, K. D.; Koch, J. A. [National Security Technologies, LLC, Livermore, California 94550 (United States); Chen, H.; Schneider, M. B. [Lawrence Livermore National Laboratory, 7000 East Avenue, Livermore, California 94550 (United States); Hill, K. W. [Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)

    2016-06-15

    A dual goniometer X-ray system was used to measure the reflectivity curve for a spherically bent quartz(211) crystal. An analysis of the dual goniometer instrument response function for the rocking curve width measurement was developed and tested against the actual measurements. The rocking curve was measured at 4510.8 eV using the Ti Kα1 characteristic spectral line. The crystal is the dispersion element for a high resolution spectrometer used for plasma studies. It was expected to have a very narrow rocking curve width. The analysis showed that we could measure the upper bound for the rocking curve width of the Qz(211) crystal. The upper bound was 58 μrad giving a lower bound for the instrument resolving power E/ΔE = 34 000. Greatly improved insight into the dual goniometer operation and its limitations was achieved.

  2. Power dependence on the rotational strength in a quartz crystal

    International Nuclear Information System (INIS)

    Joshi, N.V.; Salcedo, D.; Gil, H.

    2007-01-01

    The rotational strength of optical activity has been examined as a function of power of the incident radiation in a quartz crystal for the first time. It has been observed that the angle of rotation is proportional to the square root of the intensity of the radiation. The present experimental data directly support the recently proposed model which takes into account the electronic polarizability rather than the atomic polarizability. This model explicitly explains the role of the incident power in estimating the angle of rotation

  3. Raman scattering by hot and thermal polaritons in crystal quartz

    Energy Technology Data Exchange (ETDEWEB)

    Bogani, F.; Colocci, M.; Neri, M.; Querzoli, R.

    1984-11-01

    Nonlinear mixing of IR and visible radiation, i.e. coherent Raman scattering by polaritons driven by a CO/sub 2/ laser, has been used to obtain the dispersion curve and its width in q-space of the polariton associated to the E-phonon at 1065 cm/sup -1/ in crystal quartz. It is shown in this paper that a direct method to determine independently, with high precision, the refractive index and absorbance of a crystal can be obtained in this way. The results are compared with accurate data obtained from Raman scattering by polaritions in thermal equilibrium and very good agreement is found between the two measurements. It is finally shown that nonlinear-mixing techniques turn out to be completely consistent with the simple picture of scattering of light by hot polaritons.

  4. Electrochemical and surface characterisation of carbon-film-coated piezoelectric quartz crystals

    International Nuclear Information System (INIS)

    Pinto, Edilson M.; Gouveia-Caridade, Carla; Soares, David M.; Brett, Christopher M.A.

    2009-01-01

    The electrochemical properties of carbon films, of thickness between 200 and 500 nm, sputter-coated on gold- and platinum-coated 6 MHz piezoelectric quartz crystal oscillators, as new electrode materials have been investigated. Comparative studies under the same experimental conditions were performed on bulk electrodes. Cyclic voltammetry was carried out in 0.1 M KCl electrolyte solution, and kinetic parameters of the model redox systems Fe(CN) 6 3-/4- and [Ru(NH 3 ) 6 ] 3+/2+ as well as the electroactive area of the electrodes were obtained. Atomic force microscopy was used in order to examine the surface morphology of the films, and the properties of the carbon films and the electrode-solution interface were studied by electrochemical impedance spectroscopy. The results obtained demonstrate the feasibility of the preparation and development of nanometer thick carbon film modified quartz crystals. Such modified crystals should open up new opportunities for the investigation of electrode processes at carbon electrodes and for the application of electrochemical sensing associated with the EQCM.

  5. Electronic Nose using Gas Chromatography Column and Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Hari Agus Sujono

    2011-08-01

    Full Text Available The conventional electronic nose usually consists of an array of dissimilar chemical sensors such as quartz crystal microbalance (QCM combined with pattern recognition algorithm such as Neural network. Because of parallel processing, the system needs a huge number of sensors and circuits which may emerge complexity and inter-channel crosstalk problems. In this research, a new type of odor identification which combines between gas chromatography (GC and electronic nose methods has been developed. The system consists of a GC column and a 10-MHz quartz crystal microbalance sensor producing a unique pattern for an odor in time domain. This method offers advantages of substantially reduced size, interferences and power consumption in comparison to existing odor identification system. Several odors of organic compounds were introduced to evaluate the selectivity of the system. Principle component analysis method was used to visualize the classification of each odor in two-dimensional space. This system could resolve common organic solvents, including molecules of different classes (aromatic from alcohols as well as those within a particular class (methanol from ethanol and also fuels (premium from pertamax. The neural network can be taught to recognize the odors tested in the experiment with identification rate of 85 %. It is therefore the system may take the place of human nose, especially for poisonous odor evaluations.

  6. Continuous vacuum processing system for quartz crystal resonators

    International Nuclear Information System (INIS)

    Ney, R.J.; Hafner, E.

    1979-01-01

    An ultrahigh vacuum continuous cycle quartz crystal fabrication facility has been developed that assures an essentially contamination-free environment throughout the final manufacturing steps of the crystal unit. The system consists of five essentially tubular vacuum chambers that are interconnected through gate valves. The unplated crystal resonators, mounted in ceramic flatback frames and loaded on carrier trays, enter the vacuum system through an entrance air lock, are UV/ozone cleaned, baked at 300 0 C, plated to frequency, thermocompression sealed, and exit as completed crystal units through an exit air lock, while the bake, plate and seal chambers remain under continuous vacuum permanently. In-line conveyor belts are used, in conjunction with balanced vacuum manipulators, to move the resonator components to the various work stations. Unique high density, highly directional nozzle beam evaporation sources, capable of long term operation without reloading, are used for electroding the resonators simultaneously on both sides. The design goal for the system is a production rate of 200 units per 8 hour day; it is adaptable to automatic operation

  7. Using Quartz Crystal Microbalance for Field Measurement of Liquid Viscosities

    Directory of Open Access Journals (Sweden)

    Qingsong Bai

    2016-01-01

    Full Text Available The field measurement of liquid viscosities, especially the high viscous liquids, is challenging and often requires expensive equipment, long processing time, and lots of reagent. We use quartz crystal microbalances (QCMs operating in solution which are also sensitive to the viscosity and density of the contacting solution. QCMs are typically investigated for sensor applications in which one surface of QCM completely immersed in Newtonian liquid, but the viscous damping in liquids would cause not only large frequency shifts but also large losses in the quality factor Q leading to instability and even cessation of oscillation. A novel mass-sensitivity-based method for field measurement of liquid viscosities using a QCM is demonstrated in this paper and a model describing the influence of the liquid properties on the oscillation frequency is established as well. Two groups of verified experiments were performed and the experimental results show that the presented method is effective and possesses potential applications.

  8. Respiratory Monitoring by Porphyrin Modified Quartz Crystal Microbalance Sensors

    Directory of Open Access Journals (Sweden)

    Seung-Woo Lee

    2011-01-01

    Full Text Available A respiratory monitoring system based on a quartz crystal microbalance (QCM sensor with a functional film was designed and investigated. Porphyrins 5,10,15,20-tetrakis-(4-sulfophenyl-21H,23H-porphine (TSPP and 5,10,15,20-tetrakis-(4-sulfophenyl-21H, 23H-porphine manganese (III chloride (MnTSPP used as sensitive elements were assembled with a poly(diallyldimethyl ammonium chloride (PDDA. Films were deposited on the QCM resonators using layer-by-layer method in order to develop the sensor. The developed system, in which the sensor response reflects lung movements, was able to track human respiration providing respiratory rate (RR and respiratory pattern (RP. The sensor system was tested on healthy volunteers to compare RPs and calculate RRs. The operation principle of the proposed system is based on the fast adsorption/desorption behavior of water originated from human breath into the sensor films deposited on the QCM electrode.

  9. Data analysis for lidar and quartz crystal microbalance systems

    Science.gov (United States)

    Kent, G. S.; Deepak, A.

    1985-01-01

    Results are presented of the analysis of data taken on the stratospheric aerosol, using lidar, Quartz Crystal Microbalance (QCM), and the SAGE and SAM II satellite systems. The main objective of the work reported has been to use the data, taken with the NASA-LaRC instruments to study the stratospheric effects of volcanic eruptions during the period between the launch of the SAGE and SAM II satellite systems and October 1980. Four significant volcanic eruptions, for which data are available, occurred during this period--Soufriere, Sierra Negra, Mt. St. Helens, and Ulawun. Data on these have been analyzed to determine the changes in stratospheric mass loading produced by the eruptions, and to study the dispersion of the newly injected material.

  10. A Review of Interface Electronic Systems for AT-cut Quartz Crystal Microbalance Applications in Liquids.

    Science.gov (United States)

    Arnau, Antonio

    2008-01-21

    From the first applications of AT-cut quartz crystals as sensors in solutionsmore than 20 years ago, the so-called quartz crystal microbalance (QCM) sensor isbecoming into a good alternative analytical method in a great deal of applications such asbiosensors, analysis of biomolecular interactions, study of bacterial adhesion at specificinterfaces, pathogen and microorganism detection, study of polymer film-biomolecule orcell-substrate interactions, immunosensors and an extensive use in fluids and polymercharacterization and electrochemical applications among others. The appropriateevaluation of this analytical method requires recognizing the different steps involved andto be conscious of their importance and limitations. The first step involved in a QCMsystem is the accurate and appropriate characterization of the sensor in relation to thespecific application. The use of the piezoelectric sensor in contact with solutions stronglyaffects its behavior and appropriate electronic interfaces must be used for an adequatesensor characterization. Systems based on different principles and techniques have beenimplemented during the last 25 years. The interface selection for the specific application isimportant and its limitations must be known to be conscious of its suitability, and foravoiding the possible error propagation in the interpretation of results. This article presentsa comprehensive overview of the different techniques used for AT-cut quartz crystalmicrobalance in in-solution applications, which are based on the following principles:network or impedance analyzers, decay methods, oscillators and lock-in techniques. Theelectronic interfaces based on oscillators and phase-locked techniques are treated in detail,with the description of different configurations, since these techniques are the most used inapplications for detection of analytes in solutions, and in those where a fast sensorresponse is necessary.

  11. A Review of Interface Electronic Systems for AT-cut Quartz Crystal Microbalance Applications in Liquids

    Directory of Open Access Journals (Sweden)

    Antonio Arnau

    2008-01-01

    Full Text Available From the first applications of AT-cut quartz crystals as sensors in solutionsmore than 20 years ago, the so-called quartz crystal microbalance (QCM sensor isbecoming into a good alternative analytical method in a great deal of applications such asbiosensors, analysis of biomolecular interactions, study of bacterial adhesion at specificinterfaces, pathogen and microorganism detection, study of polymer film-biomolecule orcell-substrate interactions, immunosensors and an extensive use in fluids and polymercharacterization and electrochemical applications among others. The appropriateevaluation of this analytical method requires recognizing the different steps involved andto be conscious of their importance and limitations. The first step involved in a QCMsystem is the accurate and appropriate characterization of the sensor in relation to thespecific application. The use of the piezoelectric sensor in contact with solutions stronglyaffects its behavior and appropriate electronic interfaces must be used for an adequatesensor characterization. Systems based on different principles and techniques have beenimplemented during the last 25 years. The interface selection for the specific application isimportant and its limitations must be known to be conscious of its suitability, and foravoiding the possible error propagation in the interpretation of results. This article presentsa comprehensive overview of the different techniques used for AT-cut quartz crystalmicrobalance in in-solution applications, which are based on the following principles:network or impedance analyzers, decay methods, oscillators and lock-in techniques. Theelectronic interfaces based on oscillators and phase-locked techniques are treated in detail,with the description of different configurations, since these techniques are the most used inapplications for detection of analytes in solutions, and in those where a fast sensorresponse is necessary.

  12. Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM Sensors

    Directory of Open Access Journals (Sweden)

    Sibel Emir Diltemiz

    2017-02-01

    Full Text Available Molecularly imprinted polymers (MIPs as artificial antibodies have received considerable scientific attention in the past years in the field of (biosensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values, etc.. On the other hand, the Quartz Crystal Microbalance (QCM is an analytical tool based on the measurement of small mass changes on the sensor surface. QCM sensors are practical and convenient monitoring tools because of their specificity, sensitivity, high accuracy, stability and reproducibility. QCM devices are highly suitable for converting the recognition process achieved using MIP-based memories into a sensor signal. Therefore, the combination of a QCM and MIPs as synthetic receptors enhances the sensitivity through MIP process-based multiplexed binding sites using size, 3D-shape and chemical function having molecular memories of the prepared sensor system toward the target compound to be detected. This review aims to highlight and summarize the recent progress and studies in the field of (biosensor systems based on QCMs combined with molecular imprinting technology.

  13. Molecular Imprinting Technology in Quartz Crystal Microbalance (QCM) Sensors

    Science.gov (United States)

    Emir Diltemiz, Sibel; Keçili, Rüstem; Ersöz, Arzu; Say, Rıdvan

    2017-01-01

    Molecularly imprinted polymers (MIPs) as artificial antibodies have received considerable scientific attention in the past years in the field of (bio)sensors since they have unique features that distinguish them from natural antibodies such as robustness, multiple binding sites, low cost, facile preparation and high stability under extreme operation conditions (higher pH and temperature values, etc.). On the other hand, the Quartz Crystal Microbalance (QCM) is an analytical tool based on the measurement of small mass changes on the sensor surface. QCM sensors are practical and convenient monitoring tools because of their specificity, sensitivity, high accuracy, stability and reproducibility. QCM devices are highly suitable for converting the recognition process achieved using MIP-based memories into a sensor signal. Therefore, the combination of a QCM and MIPs as synthetic receptors enhances the sensitivity through MIP process-based multiplexed binding sites using size, 3D-shape and chemical function having molecular memories of the prepared sensor system toward the target compound to be detected. This review aims to highlight and summarize the recent progress and studies in the field of (bio)sensor systems based on QCMs combined with molecular imprinting technology. PMID:28245588

  14. Quartz crystal microbalance sensor using ionophore for ammonium ion detection.

    Science.gov (United States)

    Kosaki, Yasuhiro; Takano, Kosuke; Citterio, Daniel; Suzuki, Koji; Shiratori, Seimei

    2012-01-01

    Ionophore-based quartz crystal microbalance (QCM) ammonium ion sensors with a detection limit for ammonium ion concentrations as low as 2.2 microM were fabricated. Ionophores are molecules, which selectively bind a particular ion. In this study, one of the known ionophores for ammonium, nonactin, was used to detect ammonium ions for environmental in-situ monitoring of aquarium water for the first time. To fabricate the sensing films, poly(vinyl chloride) was used as the matrix for the immobilization of nonactin. Furthermore, the anionic additive, tetrakis (4-chlorophenyl) borate potassium salt and the plasticizer dioctyl sebacate were used to enhance the sensor properties. The sensor allowed detecting ammonium ions not only in static solution, but also in flowing water. The sensor showed a nearly linear response with the increase of the ammonium ion concentration. The QCM resonance frequency increased with the increase of ammonium ion concentration, suggesting a decreasing weight of the sensing film. The detailed response mechanism could not be verified yet. However, from the results obtained when using a different plasticizer, nitrophenyl octyl ether, it is considered that this effect is caused by the release of water molecules. Consequently, the newly fabricated sensor detects ammonium ions by discharge of water. It shows high selectivity over potassium and sodium ions. We conclude that the newly fabricated sensor can be applied for detecting ammonium ions in aquarium water, since it allows measuring low ammonium ion concentrations. This sensor will be usable for water quality monitoring and controlling.

  15. Quantifying Ion Transport in Polymers Using Electrochemical Quartz Crystal Microbalance with Dissipation

    Science.gov (United States)

    Lutkenhaus, Jodie; Wang, Shaoyang

    For polymers in energy systems, one of the most common means of quantifying ion transport is that of electrochemical impedance spectroscopy, in which an alternating electric field is applied and the resultant impedance response is recorded. While useful, this approach misses subtle details in transient film swelling, effects of hydration or solvent shells around the transporting ion, and changes in mechanical properties of the polymer. Here we present electrochemical quartz crystal microbalance with dissipation (EQCMD) monitoring as a means to quantify ion transport, dynamic swelling, and mechanical properties of polymers during electrochemical interrogation. We focus upon EQCMD characterization of the redox-active nitroxide radical polymer, poly(2,2,6,6-tetramethylpiperidinyloxy methacrylate) (PTMA). Upon oxidation, PTMA becomes positively charged, which requires the transport of a complementary anion into the polymer for electroneutrality. By EQCMD, we quantify anion transport and resultant swelling upon oxidation, as well as decoupling of contributions attributed to the ion and the solvent. We explore the effect of different lithium electrolyte salts in which each salt gives different charge storage and mass transport behavior. This is attributed to varied polymer-dopant and dopant-solvent interactions. The work was supported by the Grant DE-SC0014006 funded by the U.S. Department of Energy, Office of Science.

  16. Timescales of Quartz Crystallization and the Longevity of the Bishop Giant Magma Body

    Energy Technology Data Exchange (ETDEWEB)

    Gualda, Guilherme A.R.; Pamukcu, Ayla S.; Ghiorso, Mark S.; Anderson, Jr. , Alfred T.; Sutton, Stephen R.; Rivers, Mark L. (OFM Res.); (Vanderbilt); (UC)

    2013-04-08

    Supereruptions violently transfer huge amounts (100 s-1000 s km{sup 3}) of magma to the surface in a matter of days and testify to the existence of giant pools of magma at depth. The longevity of these giant magma bodies is of significant scientific and societal interest. Radiometric data on whole rocks, glasses, feldspar and zircon crystals have been used to suggest that the Bishop Tuff giant magma body, which erupted {approx}760,000 years ago and created the Long Valley caldera (California), was long-lived (>100,000 years) and evolved rather slowly. In this work, we present four lines of evidence to constrain the timescales of crystallization of the Bishop magma body: (1) quartz residence times based on diffusional relaxation of Ti profiles, (2) quartz residence times based on the kinetics of faceting of melt inclusions, (3) quartz and feldspar crystallization times derived using quartz+feldspar crystal size distributions, and (4) timescales of cooling and crystallization based on thermodynamic and heat flow modeling. All of our estimates suggest quartz crystallization on timescales of <10,000 years, more typically within 500-3,000 years before eruption. We conclude that large-volume, crystal-poor magma bodies are ephemeral features that, once established, evolve on millennial timescales. We also suggest that zircon crystals, rather than recording the timescales of crystallization of a large pool of crystal-poor magma, record the extended periods of time necessary for maturation of the crust and establishment of these giant magma bodies.

  17. A convenient tuning method for NMR/NQR spectrometers by using piezoelectric resonance from quartz crystals

    International Nuclear Information System (INIS)

    Yoon, J.G.; Yu, I.S.; Kwun, S.I.

    1986-01-01

    We observe that the cw or pulse NMR/NQR spectrometer tuning can be easily and conveniently adjusted by utilizing the piezoelectric resonance signal from quartz crystal sample. For an illustration some properties of the resonance signal are shown. (Author)

  18. Timescales of quartz crystallization and the longevity of the Bishop giant magma body.

    Science.gov (United States)

    Gualda, Guilherme A R; Pamukcu, Ayla S; Ghiorso, Mark S; Anderson, Alfred T; Sutton, Stephen R; Rivers, Mark L

    2012-01-01

    Supereruptions violently transfer huge amounts (100 s-1000 s km(3)) of magma to the surface in a matter of days and testify to the existence of giant pools of magma at depth. The longevity of these giant magma bodies is of significant scientific and societal interest. Radiometric data on whole rocks, glasses, feldspar and zircon crystals have been used to suggest that the Bishop Tuff giant magma body, which erupted ~760,000 years ago and created the Long Valley caldera (California), was long-lived (>100,000 years) and evolved rather slowly. In this work, we present four lines of evidence to constrain the timescales of crystallization of the Bishop magma body: (1) quartz residence times based on diffusional relaxation of Ti profiles, (2) quartz residence times based on the kinetics of faceting of melt inclusions, (3) quartz and feldspar crystallization times derived using quartz+feldspar crystal size distributions, and (4) timescales of cooling and crystallization based on thermodynamic and heat flow modeling. All of our estimates suggest quartz crystallization on timescales of magma bodies are ephemeral features that, once established, evolve on millennial timescales. We also suggest that zircon crystals, rather than recording the timescales of crystallization of a large pool of crystal-poor magma, record the extended periods of time necessary for maturation of the crust and establishment of these giant magma bodies.

  19. The response of quartz crystals coated with thin fatty acid film to organic gases

    CERN Document Server

    Jin, C N; Kim, K H; Kwon, Y S

    1999-01-01

    We tried to apply a quartz crystal as a sensor by using the resonant frequency and the resistance properties of quartz crystals. Four kinds of fatty acids that have the same head groups were coated on the surfaces of the quartz crystals, and the shift of the resonant frequency and the resistance were observed based on the lengths of the tail groups. Myristic acid (C sub 1 sub 4), palmitic acid (C sub 1 sub 6), stearic acid (C sub 1 sub 8), and arachidic acid (C sub 2 sub 0) were deposited on the surfaces of quartz crystals by using the Langmuir-Blodgett (LB) method. As a result, the resonant frequency change was more sensitive to high molecular-weight fatty acids than to low molecular-weight ones. We also observed the effect of temperature on stearic acid LB films, and the response properties of quartz crystals coated with stearic-acid LB films to organic gases were investigated. As a result, the sensitivity of quartz crystals to organic gases was higher for higher molecular-weight gas, and we found that quar...

  20. Effects of quartz on crystallization behavior of mold fluxes and microstructural characteristics of flux film.

    Science.gov (United States)

    Lei, Liu; Xiuli, Han; Mingduo, Li; Di, Zhang

    2018-01-01

    Mold fluxes are mainly prepared using cement clinker, quartz, wollastonite, borax, fluorite, soda ash and other mineral materials. Quartz, as one of the most common and essential materials, was chosen for this study to analyze itseffects on crystallization temperature, critical cooling rate, crystal incubation time, crystallization ratio and phases of flux film. We used the research methods of process mineralogy with the application of the single hot thermocouple technique, heat flux simulator, polarizing microscope, X-ray diffraction, etc. Results: By increasing the quartz content from 16 mass% to 24 mass%, the crystallization temperature, critical cooling rate and crystallization ratio of flux film decreased, and the crystal incubation time was extended. Meanwhile, the mineralogical structure of the flux film changed, with a large amount of wollastonite precipitation and a significant decrease in the cuspidine content until it reached zero. This showed a steady decline in the heat transfer control capacity of the flux film. The reason for the results above is that, by increasing the quartz content, the silicon-oxygen tetrahedron network structure promoted a rise in viscosity and restrained ion migration, inhibiting crystal nucleation and growth, leading to the weakening of the crystallization and a decline in the crystallization ratio.

  1. High-Precision Hysteresis Sensing of the Quartz Crystal Inductance-to-Frequency Converter.

    Science.gov (United States)

    Matko, Vojko; Milanović, Miro

    2016-06-28

    A new method for the automated measurement of the hysteresis of the temperature-compensated inductance-to-frequency converter with a single quartz crystal is proposed. The new idea behind this method is a converter with two programmable analog switches enabling the automated measurement of the converter hysteresis, as well as the temperature compensation of the quartz crystal and any other circuit element. Also used is the programmable timing control device that allows the selection of different oscillating frequencies. In the proposed programmable method two different inductances connected in series to the quartz crystal are switched in a short time sequence, compensating the crystal's natural temperature characteristics (in the temperature range between 0 and 50 °C). The procedure allows for the measurement of the converter hysteresis at various values of capacitance connected in parallel with the quartz crystal for the converter sensitivity setting at selected inductance. It, furthermore, enables the measurement of hysteresis at various values of inductance at selected parallel capacitance (sensitivity) connected to the quartz crystal. The article shows that the proposed hysteresis measurement of the converter, which converts the inductance in the range between 95 and 100 μH to a frequency in the range between 1 and 200 kHz, has only 7 × 10(-13) frequency instability (during the temperature change between 0 and 50 °C) with a maximum 1 × 10(-11) hysteresis frequency difference.

  2. Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions.

    Science.gov (United States)

    Arnau, A; García, J V; Jimenez, Y; Ferrari, V; Ferrari, M

    2008-07-01

    A new configuration of automatic capacitance compensation (ACC) technique based on an oscillatorlike working interface, which permits the tracking of the series resonant frequency and the monitoring of the motional resistance and the parallel capacitance of a thickness-shear mode quartz crystal microbalance sensor, is introduced. The new configuration permits an easier calibration of the system which, in principle, improves the accuracy. Experimental results are reported with 9 and 10 MHz crystals in liquids with different parallel capacitances which demonstrate the effectiveness of the capacitance compensation. Some frequency deviations from the exact series resonant frequency, measured by an impedance analyzer, are explained by the specific nonideal behavior of the circuit components. A tentative approach is proposed to solve this problem that is also common to previous ACC systems.

  3. Improved electronic interfaces for AT-cut quartz crystal microbalance sensors under variable damping and parallel capacitance conditions

    International Nuclear Information System (INIS)

    Arnau, A.; Garcia, J. V.; Jimenez, Y.; Ferrari, V.; Ferrari, M.

    2008-01-01

    A new configuration of automatic capacitance compensation (ACC) technique based on an oscillatorlike working interface, which permits the tracking of the series resonant frequency and the monitoring of the motional resistance and the parallel capacitance of a thickness-shear mode quartz crystal microbalance sensor, is introduced. The new configuration permits an easier calibration of the system which, in principle, improves the accuracy. Experimental results are reported with 9 and 10 MHz crystals in liquids with different parallel capacitances which demonstrate the effectiveness of the capacitance compensation. Some frequency deviations from the exact series resonant frequency, measured by an impedance analyzer, are explained by the specific nonideal behavior of the circuit components. A tentative approach is proposed to solve this problem that is also common to previous ACC systems

  4. Quartz crystal microbalance gas sensor with nanocrystalline diamond sensitive layer

    Czech Academy of Sciences Publication Activity Database

    Varga, Marián; Laposa, A.; Kulha, Pavel; Kroutil, J.; Husák, M.; Kromka, Alexander

    2015-01-01

    Roč. 252, č. 11 (2015), s. 2591-2597 ISSN 0370-1972 R&D Projects: GA ČR(CZ) GBP108/12/G108 Institutional support: RVO:68378271 Keywords : gas sensor * nanocrystalline diamond * quartz resonator * thickness shear mode Subject RIV: JB - Sensor s, Measurment, Regulation Impact factor: 1.522, year: 2015

  5. High-Precision Hysteresis Sensing of the Quartz Crystal Inductance-to-Frequency Converter

    Directory of Open Access Journals (Sweden)

    Vojko Matko

    2016-06-01

    Full Text Available A new method for the automated measurement of the hysteresis of the temperature-compensated inductance-to-frequency converter with a single quartz crystal is proposed. The new idea behind this method is a converter with two programmable analog switches enabling the automated measurement of the converter hysteresis, as well as the temperature compensation of the quartz crystal and any other circuit element. Also used is the programmable timing control device that allows the selection of different oscillating frequencies. In the proposed programmable method two different inductances connected in series to the quartz crystal are switched in a short time sequence, compensating the crystal’s natural temperature characteristics (in the temperature range between 0 and 50 °C. The procedure allows for the measurement of the converter hysteresis at various values of capacitance connected in parallel with the quartz crystal for the converter sensitivity setting at selected inductance. It, furthermore, enables the measurement of hysteresis at various values of inductance at selected parallel capacitance (sensitivity connected to the quartz crystal. The article shows that the proposed hysteresis measurement of the converter, which converts the inductance in the range between 95 and 100 μH to a frequency in the range between 1 and 200 kHz, has only 7 × 10−13 frequency instability (during the temperature change between 0 and 50 °C with a maximum 1 × 10−11 hysteresis frequency difference.

  6. On-line monitoring of the crystallization process: relationship between crystal size and electrical impedance spectra

    International Nuclear Information System (INIS)

    Zhao, Yanlin; Yao, Jun; Wang, Mi

    2016-01-01

    On-line monitoring of crystal size in the crystallization process is crucial to many pharmaceutical and fine-chemical industrial applications. In this paper, a novel method is proposed for the on-line monitoring of the cooling crystallization process of L-glutamic acid (LGA) using electrical impedance spectroscopy (EIS). The EIS method can be used to monitor the growth of crystal particles relying on the presence of an electrical double layer on the charged particle surface and the polarization of double layer under the excitation of alternating electrical field. The electrical impedance spectra and crystal size were measured on-line simultaneously by an impedance analyzer and focused beam reflectance measurement (FBRM), respectively. The impedance spectra were analyzed using the equivalent circuit model and the equivalent circuit elements in the model can be obtained by fitting the experimental data. Two equivalent circuit elements, including capacitance ( C 2 ) and resistance ( R 2 ) from the dielectric polarization of the LGA solution and crystal particle/solution interface, are in relation with the crystal size. The mathematical relationship between the crystal size and the equivalent circuit elements can be obtained by a non-linear fitting method. The function can be used to predict the change of crystal size during the crystallization process. (paper)

  7. Correct interpretation of diffraction properties of quartz crystals for X-ray optics applications

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Xian-Rong; Gog, Thomas; Kim, Jungho; Kasman, Elina; Said, Ayman H.; Casa, Diego M.; Wieczorek, Michael; Hönnicke, Marcelo G.; Assoufid, Lahsen

    2018-02-01

    Quartz has hundreds of strong Bragg reflections that may offer a great number of choices for making fixed-angle X-ray analyzers and polarizers at virtually any hard X-ray energies with selectable resolution. However, quartz crystals, unlike silicon and germanium, are chiral and may thus appear in two different forms of handedness that are mirror images. Furthermore, because of the threefold rotational symmetry along thecaxis, the {h1h2h3L} and {h2h1h3L} Bragg reflections may have quite different Darwin bandwidth, reflectivity and angular acceptance, although they have the same Bragg angle. The design of X-ray optics from quartz crystals therefore requires unambiguous determination of the orientation, handedness and polarity of the crystals. The Laue method and single-axis diffraction technique can provide such information, but the variety of conventions used in the literature to describe quartz structures has caused widespread confusion. The current studies give detailed guidelines for design and fabrication of quartz X-ray optics, with special emphasis on the correct interpretation of Laue patterns in terms of the crystallography and diffraction properties of quartz. Meanwhile, the quartz crystals examined were confirmed by X-ray topography to have acceptably low densities of dislocations and other defects, which is the foundation for developing high-resolution quartz-based X-ray optics.

  8. Temperature effect on phase states of quartz nano-crystals in silicon single crystal

    International Nuclear Information System (INIS)

    Kalanov, M.U.; Ibragimova, E.M.; Khamraeva, R.N.; Rustamova, V.M.; Ummatov, Kh.D.

    2006-01-01

    Full text: Oxygen penetrates into the silicon lattice up to the concentration of 2·10 18 cm -3 in the course of growing [1]. By the author's opinion at a low oxygen content the formation of solid solution is possible in the local defect places of the silicon single crystal lattice due to the difference in effective ion radius of oxygen and silicon (r O 0.176 and r Si = 0.065 nm). Upon reaching some critical content (∼ 10 17 cm -3 ), it becomes favorable energetically for oxygen ions to form precipitates (SiO x ) and finally a dielectric layer (stoichiometric inclusions of SiO 2 ). It was shown later that depending on the growth conditions, indeed the quartz crystal inclusions are formed in the silicon single crystals at an amount of 0.3 /0.5 wt. % [2]. However the authors did not study a phase state of the quartz inclusions. Therefore the aim of this work was to study a phase state of the quartz inclusions in silicon crystal at various temperatures. We examined the silicon single crystals grown by Czochralski technique, which were cut in (111) plane in the form of disk of 20 mm diameter and 1.5 thickness and had hole conductivity with the specific resistance ρ o ≅ 1/10 Ohm cm. The dislocation density was N D ≅ 10 1 /10 3 cm -2 , the concentrations of oxygen and boron were N 0 ≅ 2/ 4·10 17 cm -3 and N B ≅ 3*10 15 cm -3 . Structure was analyzed at the set-up DRON-UM1 with high temperature supply UVD-2000 ( CuK = 0.1542 nm) at the temperatures of 300, 1173 and 1573 K measured with platinum-platinum-rhodium thermocouple. The high temperature diffraction spectrum measured at 1573 K in the angle range (2Θ≅10/70 d egree ) there is only one main structure reflection (111) with a high intensity and d/n ≅ 0.3136 nm (2 Θ≅ 28.5 d egree ) from the matrix lattice of silicon single crystal. The weak line at 2 Θ≅ 25.5 d egree ( d/n≅0.3136 nm) is β component of the main reflection (111), and the weak structure peak at 2Θ≅59 d egree ( d/n≅ 0.1568 nm

  9. The quartz crystal microbalance in soft matter research fundamentals and modeling

    CERN Document Server

    Johannsmann, Diethelm

    2014-01-01

    This book describes the physics of the second-generation quartz crystal microbalance (QCM), a fundamental method of analysis for soft matter at interfaces.From a device for measuring film thickness in vacuum, the quartz crystal microbalance (QCM) has in the past two decades evolved into a versatile instrument for analyzing soft matter at solid/liquid and solid/gas interfaces that found applications in diverse fields including the life sciences, material science, polymer research and electrochemistry. As a consequence of this success, the QCM is now being used by scientists with a wide variety

  10. A study of positron properties in quartz crystals and synthetic silica glass

    International Nuclear Information System (INIS)

    Anwand, W.; Brauer, G.; Hesegawa, M.; Dersch, O.; Rauch, F.

    2001-01-01

    The monoenergetic positron beamline 'SPONSOR' at Rossendorf has been used to investigate the positron behaviour in a naturally grown Brasilian quartz, two synthetic quartz crystals of different origin, and synthetic silica glass. The measurements allow us to obtain the positron diffusion length of free positrons and Bloch para-positronium, if formed, in these materials. In addition, hydrothermal treatment of a synthetic quartz has been used to introduce hydrogen into the crystal up to a certain depth. The presence of hydrogen is found to influence the formation of para-positronium. The depth distribution of hydrogen has been measured independently by the nuclear reaction analysis, and will be discussed in comparison with the results deduced from the positron studies. (author)

  11. Quartz Crystal Microbalance: A tool for analyzing loss of volatile compounds, gas sorption, and curing kinetics

    Energy Technology Data Exchange (ETDEWEB)

    Bajric, Sendin [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-03-16

    Los Alamos National Laboratory (LANL) has recently procured a quartz crystal microbalance (QCM). Current popular uses are biological sensors, surface chemistry, and vapor detection. LANL has projects related to analyzing curing kinetics, measuring gas sorption on polymers, and analyzing the loss of volatile compounds in polymer materials. The QCM has yet to be employed; however, this review will cover the use of the QCM in these applications and its potential.

  12. Quartz Crystal Microbalance Studies Of Dimethyl Methylphosphonate Sorption Into Trisilanolphenyl-Poss Films

    Science.gov (United States)

    2006-11-06

    QUARTZ CRYSTAL MICROBALANCE STUDIES OF DIMETHYL METHYLPHOSPHONATE SORPTION INTO TRISILANOLPHENYL-POSS FILMS Joshua D. Kittle Thesis ...subsequent DIMP layers form a solid- like phase as a result of nucleated growth around the first layer. Bertilsson et al. studied the adsorption of...of QCMs in liquids,55, 56 opening the door to a variety of applications, including the study of electrodeposition of metals,57,65 electrochemical

  13. Functional Durability of a Quartz Crystal Microbalance Sensor for the Rapid Detection of Salmonella in Liquids from Poultry Packaging

    National Research Council Canada - National Science Library

    Olsen, Eric

    2000-01-01

    .... A rapid, sensitive (350 +/- 150 cells ml/cm) quartz crystal microbalance biosensor, layered with heat-treated anti-Salmonella-phospholipid monolayers by the Langmuir-Blodgett technique, has been evaluated by immersion testing in chicken exudate...

  14. INTERFACE LAYER TO IMPROVE POLYSTYRENE ATTACHMENT ON A QUARTZ CRYSTAL RESONATOR

    Directory of Open Access Journals (Sweden)

    Doris Susana Llanes

    Full Text Available Technologies for thin film deposition have been used to improve the functionalization of quartz crystal resonators (QCR; such technologies, for example, are spin coating and Langmuir-Blodgett (LB film preparation. These experiments are required because the film uniformity and homogeneity over the quartz crystal resonator are fundamental for its applications as chemical and biological sensors. Film deposition of polystyrene (PS particles, as well as polyvinyl chloride (PVC, was performed in solvents such as cyclohexanone, tetrahydrofuran (THF, dimethylformamide and chloroform at different concentrations using the spin coating procedure on wafer targets. The film quality was determined by optical microscopy, ellipsometry, and profilometry. Additionally, films on wafers or QCR with gold surface have been prepared by spreading the mentioned substances on an aqueous subphase and transferring it by dipping from the subphase surface onto the target. For LB film preparation arachidic acid and PS particles have been used. Prepared mono- or multilayered films of these substances on wafer or gold quartzes have been controlled additionally by IR-spectrometry. The resonant behavior of QCR before and after surface coating has been measured with a network analyzer. In combination with a graphical user interface the data could be easily recorded and visualized.

  15. Quartz-crystal microbalance study for characterizing atomic oxygen in plasma ash tools

    International Nuclear Information System (INIS)

    Srivastava, A.K.; Sakthivel, P.

    2001-01-01

    This article discusses the measurement of atomic oxygen (AO) concentrations in an oxygen discharge using a quartz-crystal microbalance (QCM). This is a device that has been previously used for monitoring thin-film deposition, among several other applications. The sensor consists of a silver-coated quartz crystal that oscillates at its specific resonant frequency (typically, at about 6 MHz), which is dependent on the mass of the crystal. When exposed to AO, the silver oxidizes rapidly, resulting in a change in its mass, and a consequent change in this frequency. The frequency change is measured with a counter, and when plotted versus time, it may be fit to a standard diffusion-limited oxide-growth model. This model is then used to determine the specific AO flux to the crystal, and by inference, to the wafer. Initial results of QCM measurements in the FusionGemini Plasma Asher (GPL TM -standard downstream microwave asher) and FusionGemini Enhanced Strip (GES TM -fluorine compatible enhanced strip asher) are presented in this article. The results indicate AO densities of the order of 10 12 cm -3 on the wafer. There is a marked increase in AO concentration with addition of nitrogen into the plasma, and a decrease in AO concentration with increasing pressure at constant flow. Effects of increasing the total plasma volume in the enhanced strip tool on AO production are discussed

  16. Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

    Science.gov (United States)

    Bechtold, Mary M.

    1995-01-01

    When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings

  17. Studies of jet fuel additives using the quartz crystal microbalance and pressure monitoring at 140 C

    Energy Technology Data Exchange (ETDEWEB)

    Zabarnick, S.; Grinstead, R.R. [Univ. of Dayton Research Institute, OH (United States)

    1995-05-01

    The quartz crystal microbalance (QCM) and pressure monitoring are used for the evaluation of jet fuel additives for the improvement of jet fuel thermal stability. The mechanisms of additive behavior are determined by measuring the time dependent deposition with the QCM and oxidation by pressure measurements. Studies at various additive concentrations permits the determination of optimum additive concentrations. Additive packages made of mixtures of antioxidants, detergent/dispersants, and metal deactivators are shown to yield good improvements in thermal stability over a wide range of jet fuel types.

  18. Epoxy Resin Modified Quartz Crystal Microbalance Sensor for Chemical Warfare Agent Sulfur Mustard Vapor Detection

    Directory of Open Access Journals (Sweden)

    Rajendra BUNKAR

    2010-02-01

    Full Text Available An epoxy resin polymer coated quartz crystal microbalance (PC-QCM is used for detection of sulfur mustard vapor (SM. When SM vapor is exposed to PC-QCM sensor frequency shift is observed. The response of the sensor in ambient condition is 554 Hz with ±10 % variation upon exposure of 155 ppm of the SM concentration. The observed response loss is nearly 40 % over the period of 15 months. The response of the sensor is higher for SM than compare to structurally similar chloroethyl ether (CEE and other interferences.

  19. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    Science.gov (United States)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-11-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.

  20. An Electrochemical Quartz Crystal Microbalance Multisensor System Based on Phthalocyanine Nanostructured Films: Discrimination of Musts

    Directory of Open Access Journals (Sweden)

    Celia Garcia-Hernandez

    2015-11-01

    Full Text Available An array of electrochemical quartz crystal electrodes (EQCM modified with nanostructured films based on phthalocyanines was developed and used to discriminate musts prepared from different varieties of grapes. Nanostructured films of iron, nickel and copper phthalocyanines were deposited on Pt/quartz crystals through the Layer by Layer technique by alternating layers of the corresponding phthalocyanine and poly-allylamine hydrochloride. Simultaneous electrochemical and mass measurements were used to study the mass changes accompanying the oxidation of electroactive species present in must samples obtained from six Spanish varieties of grapes (Juan García, Prieto Picudo, Mencía Regadío, Cabernet Sauvignon, Garnacha and Tempranillo. The mass and voltammetric outputs were processed using three-way models. Parallel Factor Analysis (PARAFAC was successfully used to discriminate the must samples according to their variety. Multi-way partial least squares (N-PLS evidenced the correlations existing between the voltammetric data and the polyphenolic content measured by chemical methods. Similarly, N-PLS showed a correlation between mass outputs and parameters related to the sugar content. These results demonstrated that electronic tongues based on arrays of EQCM sensors can offer advantages over arrays of mass or voltammetric sensors used separately.

  1. Lectin typing of Campylobacter jejuni using a novel quartz crystal microbalance technique

    Energy Technology Data Exchange (ETDEWEB)

    Yakovleva, Maria E., E-mail: maria.yakovleva@gmail.com [Department of Infectious Diseases and Medical Microbiology, Lund University, 223 62 Lund (Sweden); Moran, Anthony P. [Department of Microbiology, School of Natural Sciences, National University of Ireland, Galway (Ireland); Safina, Gulnara R. [Department of Analytical and Marine Chemistry, University of Gothenburg, 412 96 Gothenburg (Sweden); Wadstroem, Torkel [Department of Infectious Diseases and Medical Microbiology, Lund University, 223 62 Lund (Sweden); Danielsson, Bengt [Acromed Invest AB, Magistratsvaegen 10, 226 43 Lund (Sweden)

    2011-05-23

    Seven Campylobacter jejuni strains were characterised by a lectin typing assay. The typing system was based on a quartz crystal microbalance technique (QCM) with four commercially available lectins (wheat germ agglutinin, Maackia amurensis lectin, Lens culinaris agglutinin, and Concanavalin A), which were chosen for their differing carbohydrate specificities. Initially, the gold surfaces of the quartz crystals were modified with 11-mercaptoundecanoic acid followed by lectin immobilisation using a conventional amine-coupling technique. Bacterial cells were applied for lectin typing without preliminary treatment, and resonant frequency and dissipation responses were recorded. The adhesion of microorganisms on lectin surfaces was confirmed by atomic force microscopy. Scanning was performed in the tapping mode and the presence of bacteria on lectin-coated surfaces was successfully demonstrated. A significant difference in the dissipation response was observed for different C. jejuni strains which made it possible to use this parameter for discriminating between bacterial strains. In summary, the QCM technique proved a powerful tool for the recognition and discrimination of C. jejuni strains. The approach may also prove applicable to strain discrimination of other bacterial species, particularly pathogens.

  2. Electroacoustic polymer microchip as an alternative to quartz crystal microbalance for biosensor development.

    Science.gov (United States)

    Gamby, Jean; Lazerges, Mathieu; Girault, Hubert H; Deslouis, Claude; Gabrielli, Claude; Perrot, Hubert; Tribollet, Bernard

    2008-12-01

    Laser photoablation of poly(ethylene terephthalate) (PET), a flexible dielectric organic polymer, was used to design an acoustic miniaturized DNA biosensor. The microchip device includes a 100-microm-thick PET layer, with two microband electrodes patterned in photoablated microchannels on one side and a depressed photoablated disk decorated by gold sputtered layer on the other side. Upon application of an electric signal between the two electrodes, an electroacoustic resonance phenomenon at approximately 30 MHz was established through the microelectrodes/PET/ gold layer interface. The electroacoustic resonance response was fitted with a series RLC motional arm in parallel with a static Co arm of a Buttlerworth-Van Dyke equivalent circuit: admittance spectra recorded after successive cycles of DNA hybridization on the gold surface showed reproducible changes on R, L, and C parameters. The same hybridizations runs were performed concomitantly on a 27-MHz (9 MHz, third overtone) quartz crystal microbalance in order to validate the PET device developed for bioanalysis applications. The electroacoustic PET device, approximately 100 times smaller than a microbalance quartz crystal, is interesting for the large-scale integration of acoustic sensors in biochips.

  3. Lectin typing of Campylobacter jejuni using a novel quartz crystal microbalance technique

    International Nuclear Information System (INIS)

    Yakovleva, Maria E.; Moran, Anthony P.; Safina, Gulnara R.; Wadstroem, Torkel; Danielsson, Bengt

    2011-01-01

    Seven Campylobacter jejuni strains were characterised by a lectin typing assay. The typing system was based on a quartz crystal microbalance technique (QCM) with four commercially available lectins (wheat germ agglutinin, Maackia amurensis lectin, Lens culinaris agglutinin, and Concanavalin A), which were chosen for their differing carbohydrate specificities. Initially, the gold surfaces of the quartz crystals were modified with 11-mercaptoundecanoic acid followed by lectin immobilisation using a conventional amine-coupling technique. Bacterial cells were applied for lectin typing without preliminary treatment, and resonant frequency and dissipation responses were recorded. The adhesion of microorganisms on lectin surfaces was confirmed by atomic force microscopy. Scanning was performed in the tapping mode and the presence of bacteria on lectin-coated surfaces was successfully demonstrated. A significant difference in the dissipation response was observed for different C. jejuni strains which made it possible to use this parameter for discriminating between bacterial strains. In summary, the QCM technique proved a powerful tool for the recognition and discrimination of C. jejuni strains. The approach may also prove applicable to strain discrimination of other bacterial species, particularly pathogens.

  4. A STUDY OF THE PRESSURE SOLUTION AND DEFORMATION OF QUARTZ CRYSTALS AT HIGH pH AND UNDER HIGH STRESS

    Directory of Open Access Journals (Sweden)

    JUNG-HAE CHOI

    2013-02-01

    Full Text Available Bentonite is generally used as a buffer material in high-level radioactive waste disposal facilities and consists of 50% quartz by weight. Quartz strongly affects the behavior of bentonite over very long periods. For this reason, quartz dissolution experiment was performed under high-pressure and high-alkalinity conditions based on the conditions found in a high-level radioactive waste disposal facility located deep underground. In this study, two quartz dissolution experiments were conducted on 1 quartz beads under low-pressure and high-alkalinity conditions and 2 a single quartz crystal under high-pressure and high-alkalinity conditions. Following the experiments, a confocal laser scanning microscope (CLSM was used to observe the surfaces of experimental samples. Numerical analyses using the finite element method (FEM were also performed to quantify the deformation of contact area. Quartz dissolution was observed in both experiments. This deformation was due to a concentrated compressive stress field, as indicated by the quartz deformation of the contact area through the FEM analysis. According to the numerical results, a high compressive stress field acted upon the neighboring contact area, which showed a rapid dissolution rate compared to other areas of the sample.

  5. Quartz Crystal Microbalance Coated with Sol-gel-derived Thin Films as Gas Sensor for NO Detection

    Directory of Open Access Journals (Sweden)

    S. J. O’Shea

    2003-10-01

    Full Text Available This paper presents the possibilities and properties of Indium tin oxide (ITO-covered quartz crystal as a NOx toxic gas-sensor. The starting sol-gel solution was prepared by mixing indium chloride dissolved in acetylacetone and tin chloride dissolved in ethanol (0-20% by weight. The ITO thin films were deposited on the gold electrodes of quartz crystal by spin-coating technique and subsequently followed a standard photolithography to pattern the derived films to ensure all sensors with the same sensing areas. All heat treatment processes were controlled below 500°C in order to avoid the piezoelectric characteristics degradation of quartz crystal (Quartz will lose its piezoelectricity at ~573°C due to the phase change from α to β. The electrical and structural properties of ITO thin films were characterized with Hall analysis system, TG/DTA, XRD, XPS, SEM and etc. The gas sensor had featured with ITO thin films of ~100nm as the receptor to sense the toxic gas NO and quartz crystal with frequency of 10MHz as the transducer to transfer the surface reactions (mass loading, etc into the frequency shift. A homemade setup had been employed to measure the sensor response under the static mode. The experimental results had indicated that the ITO-coated QCM had a good sensitivity for NO gas, ~12Hz/100ppm within 5mins. These results prove that the ITO-covered quartz crystals are usable as a gas sensor and as an analytical device.

  6. Low-cost scalable quartz crystal microbalance array for environmental sensing

    Energy Technology Data Exchange (ETDEWEB)

    Anazagasty, Cristain [University of Puerto Rico; Hianik, Tibor [Comenius University, Bratislava, Slovakia; Ivanov, Ilia N [ORNL

    2016-01-01

    Proliferation of environmental sensors for internet of things (IoT) applications has increased the need for low-cost platforms capable of accommodating multiple sensors. Quartz crystal microbalance (QCM) crystals coated with nanometer-thin sensor films are suitable for use in high-resolution (~1 ng) selective gas sensor applications. We demonstrate a scalable array for measuring frequency response of six QCM sensors controlled by low-cost Arduino microcontrollers and a USB multiplexer. Gas pulses and data acquisition were controlled by a LabVIEW user interface. We test the sensor array by measuring the frequency shift of crystals coated with different compositions of polymer composites based on poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) while films are exposed to water vapor and oxygen inside a controlled environmental chamber. Our sensor array exhibits comparable performance to that of a commercial QCM system, while enabling high-throughput 6 QCM testing for under $1,000. We use deep neural network structures to process sensor response and demonstrate that the QCM array is suitable for gas sensing, environmental monitoring, and electronic-nose applications.

  7. Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance

    Science.gov (United States)

    Li, Ning; Meng, Xiaofeng; Nie, Jing

    2017-05-01

    A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.

  8. Polyacrylonitrile Nanofiber-Based Quartz Crystal Microbalance for Sensitive Detection of Safrole

    Directory of Open Access Journals (Sweden)

    Aditya Rianjanu

    2018-04-01

    Full Text Available Safrole is the main precursor for producing the amphetamine-type stimulant (ATS drug, N-methyl-3,4-methylenedioxyamphetamine (MDMA, also known as ecstasy. We devise a polyacrylonitrile (PAN nanofiber-based quartz crystal microbalance (QCM for detecting safrole. The PAN nanofibers were fabricated by direct electrospinning to modify the QCM chips. The PAN nanofiber on the QCM chips has a diameter of 240 ± 10 nm. The sensing of safrole by QCM modified with PAN nanofiber shows good reversibility and an apparent sensitivity of 4.6 Hz·L/mg. The proposed method is simple, inexpensive, and convenient for detecting safrole, and can be an alternative to conventional instrumental analytical methods for general volatile compounds.

  9. Separate density and viscosity measurements of unknown liquid using quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Feng Tan

    2016-09-01

    Full Text Available Aqueous liquids have a wide range of applications in many fields. Basic physical properties like the density and the viscosity have great impacts on the functionalities of a given ionic liquid. For the millions kinds of existing liquids, only a few have been systematically measured with the density and the viscosity using traditional methods. However, these methods are limited to measure the density and the viscosity of an ionic liquid simultaneously especially in processing micro sample volumes. To meet this challenge, we present a new theoretical model and a novel method to separate density and viscosity measurements with single quartz crystal microbalance (QCM in this work. The agreement of experimental results and theocratical calculations shows that the QCM is capable to measure the density and the viscosity of ionic liquids.

  10. Quartz crystal microbalance-based system for high-sensitivity differential sputter yield measurements

    International Nuclear Information System (INIS)

    Rubin, B.; Topper, J. L.; Farnell, C. C.; Yalin, A. P.

    2009-01-01

    We present a quartz crystal microbalance-based system for high sensitivity differential sputter yield measurements of different target materials due to ion bombardment. The differential sputter yields can be integrated to find total yields. Possible ion beam conditions include ion energies in the range of 30-350 eV and incidence angles of 0 deg. - 70 deg. from normal. A four-grid ion optics system is used to achieve a collimated ion beam at low energy (<100 eV) and a two-grid ion optics is used for higher energies (up to 750 eV). A complementary weight loss approach is also used to measure total sputter yields. Validation experiments are presented that confirm high sensitivity and accuracy of sputter yield measurements.

  11. Alcohol vapours sensor based on thin polyaniline salt film and quartz crystal microbalance.

    Science.gov (United States)

    Ayad, Mohamad M; Torad, Nagy L

    2009-06-15

    A sensor based on the quartz crystal microbalance (QCM) technique was developed for detection of a number of primary aliphatic alcohols such as ethanol, methanol, 1-propanol, and 2-propanol vapours. Detection was based on a sensitive and a thin film of polyaniline, emeraldine salt (ES), coated the QCM electrode. The frequency shifts (Delta f) of the QCM were increased due to the vapour absorption into the ES film. The values of Delta f were found to be linearly correlated with the concentrations of alcohols vapour in mg L(-1). The changes in frequency are due to the hydrophilic character of the ES and the electrostatic interaction as well as the type of the alcohol. The sensor shows a good reproducibility and reversibility. The diffusion and diffusion coefficient (D) of different alcohols vapour were determined. It was found that the sensor follows Fickian kinetics.

  12. A sensor of alcohol vapours based on thin polyaniline base film and quartz crystal microbalance.

    Science.gov (United States)

    Ayad, Mohamad M; El-Hefnawey, Gad; Torad, Nagy L

    2009-08-30

    Thin films of polyaniline base, emeraldine base (EB), coating on the quartz crystal microbalance (QCM) electrode were used as a sensitive layer for the detection of a number of primary aliphatic alcohols such as ethanol, methanol, 2-propanol and 1-propanol vapours. The frequency shifts (Deltaf) of the QCM were increased due to the vapour adsorption into the EB film. Deltaf were found to be linearly correlated with the concentrations of alcohols vapour in part per million (ppm). The sensitivity of the sensor was found to be governed by the chemical structure of the alcohol. The sensor shows a good reproducibility and reversibility. The diffusions of different alcohols vapour were studied and the diffusion coefficients (D) were calculated. It is concluded that the diffusion of the vapours into the EB film follows Fickian kinetics.

  13. Investigating calcite growth rates using a quartz crystal microbalance with dissipation (QCM-D)

    Science.gov (United States)

    Cao, Bo; Stack, Andrew G.; Steefel, Carl I.; DePaolo, Donald J.; Lammers, Laura N.; Hu, Yandi

    2018-02-01

    Calcite precipitation plays a significant role in processes such as geological carbon sequestration and toxic metal sequestration and, yet, the rates and mechanisms of calcite growth under close to equilibrium conditions are far from well understood. In this study, a quartz crystal microbalance with dissipation (QCM-D) was used for the first time to measure macroscopic calcite growth rates. Calcite seed crystals were first nucleated and grown on sensors, then growth rates of calcite seed crystals were measured in real-time under close to equilibrium conditions (saturation index, SI = log ({Ca2+}/{CO32-}/Ksp) = 0.01-0.7, where {i} represent ion activities and Ksp = 10-8.48 is the calcite thermodynamic solubility constant). At the end of the experiments, total masses of calcite crystals on sensors measured by QCM-D and inductively coupled plasma mass spectrometry (ICP-MS) were consistent, validating the QCM-D measurements. Calcite growth rates measured by QCM-D were compared with reported macroscopic growth rates measured with auto-titration, ICP-MS, and microbalance. Calcite growth rates measured by QCM-D were also compared with microscopic growth rates measured by atomic force microscopy (AFM) and with rates predicted by two process-based crystal growth models. The discrepancies in growth rates among AFM measurements and model predictions appear to mainly arise from differences in step densities, and the step velocities were consistent among the AFM measurements as well as with both model predictions. Using the predicted steady-state step velocity and the measured step densities, both models predict well the growth rates measured using QCM-D and AFM. This study provides valuable insights into the effects of reactive site densities on calcite growth rate, which may help design future growth models to predict transient-state step densities.

  14. Biomimetic piezoelectric quartz crystal sensor with chloramphenicol-imprinted polymer sensing layer.

    Science.gov (United States)

    Ebarvia, Benilda S; Ubando, Isaiah E; Sevilla, Fortunato B

    2015-11-01

    The measurement of banned antibiotic like chloramphenicol is significant for customer protection and safety. The presence of residual antibiotics in foods and food products of animal origin could pose as health hazards and affect food quality for global acceptance. In this study, the potential of a chloramphenicol sensor based on molecularly imprinted polymer (MIP) coupled with a piezoelectric quartz crystal was explored. The MIP was prepared by precipitation polymerization at 60 °C. Methacrylic acid was used as monomer, trimethylolpropane trimethacrylate (TRIM) as crosslinker, and chloramphenicol as the template. Template removal on the resulting polymer was done by extraction using methanol-acetic acid. Characterization of the MIP and NIP were conducted by spectroscopic and microscopic methods. These further supported the imprinting and rebinding process of chloramphenicol to the polymer matrix. The chloramphenicol sensor was devised by spin-coating onto one side of the 10 MHz AT-cut quartz crystal the MIP suspension in polyvinylchloride-tetrahydrofuran (6:2:1 w/w/v) solution. Optimization of sensor response was performed by varying the type of cross-linker, amount of MIP sensing layer, curing time, and pH. The sensor exhibited good sensitivity of about 73 Hz/log (conc., µg mL(-1)) and good repeatability (rsd<10%). A linear relationship (r(2)=0.9901) between frequency shift and chloramphenicol concentration in the range of 1×10(-6) up to 1×10(-1) µg/mL was obtained. The sensor response was highly selective to chloramphenicol than with other compounds of similar chemical structures. Acceptable percent recovery was obtained for real sample analysis using the sensor. The proposed sensor could be a promising low cost and highly sensitive approach for residual chloramphenicol quantification in food products. Copyright © 2015 Elsevier B.V. All rights reserved.

  15. Quantitative Rheometry of Thin Soft Materials Using the Quartz Crystal Microbalance with Dissipation.

    Science.gov (United States)

    Sadman, Kazi; Wiener, Clinton G; Weiss, R A; White, Christopher C; Shull, Kenneth R; Vogt, Bryan D

    2018-03-20

    In the inertial limit, the resonance frequency of the quartz crystal microbalance (QCM) is related to the coupled mass on the quartz sensor through the Sauerbrey expression that relates the mass to the change in resonance frequency. However, when the thickness of the film is sufficiently large, the relationship becomes more complicated and both the frequency and damping of the crystal resonance must be considered. In this regime, a rheological model of the material must be used to accurately extract the adhered film's thickness, shear modulus, and viscoelastic phase angle from the data. In the present work we examine the suitability of two viscoelastic models, a simple Voigt model ( Physica Scripta 1999, 59, 391-396) and a more realistic power-law model ( Langmuir 2015, 31, 4008-4017), to extract the rheological properties of a thermoresponsive hydrogel film. By changing temperature and initial dry film thickness of the gel, the operation of QCM was traversed from the Sauerbrey limit, where viscous losses do not impact the frequency, through the regime where the QCM response is sensitive to viscoelastic properties. The density-shear modulus and the viscoelastic phase angle from the two models are in good agreement when the shear wavelength ratio, d/λ n , is in the range of 0.05-0.20, where d is the film thickness and λ n is the wavelength of the mechanical shear wave at the n th harmonic. We further provide a framework for estimating the physical properties of soft materials in the megahertz regime by using the physical behavior of polyelectrolyte complexes. This provides the user with an approximate range of allowable film thicknesses for accurate viscoelastic analysis with either model, thus enabling better use of the QCM-D in soft materials research.

  16. Towards vibrational spectroscopy on surface-attached colloids performed with a quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Diethelm Johannsmann

    2016-12-01

    Full Text Available Colloidal spheres attached to a quartz crystal microbalance (QCM produce the so-called “coupled resonances”. They are resonators of their own, characterized by a particle resonance frequency, a resonance bandwidth, and a modal mass. When the frequency of the main resonator comes close to the frequency of the coupled resonance, the bandwidth goes through a maximum. A coupled resonance can be viewed as an absorption line in acoustic shear-wave spectroscopy. The known concepts from spectroscopy apply. This includes the mode assignment problem, selection rules, and the oscillator strength. In this work, the mode assignment problem was addressed with Finite Element calculations. These reveal that a rigid sphere in contact with a QCM displays two modes of vibration, termed “slipping” and “rocking”. In the slipping mode, the sphere rotates about its center; it exerts a tangential force onto the resonator surface at the point of contact. In the rocking mode, the sphere rotates about the point of contact; it exerts a torque onto the substrate. In liquids, both axes of rotation are slightly displaced from their ideal positions. Characteristic for spectroscopy, the two modes do not couple to the mechanical excitation equally well. The degree of coupling is quantified by an oscillator strength. Because the rocking mode mostly exerts a torque (rather than a tangential force, its coupling to the resonator's tangential motion is weak; the oscillator strength consequently is small. Recent experiments on surface-adsorbed colloidal spheres can be explained by the mode of vibration being of the rocking type. Keywords: Quartz crystal microbalance, Coupled resonance, Biocolloids, Adsorption

  17. Third harmonic frequency generation by type-I critically phase-matched LiB3O5 crystal by means of optically active quartz crystal.

    Science.gov (United States)

    Gapontsev, Valentin P; Tyrtyshnyy, Valentin A; Vershinin, Oleg I; Davydov, Boris L; Oulianov, Dmitri A

    2013-02-11

    We present a method of third harmonic generation at 355 nm by frequency mixing of fundamental and second harmonic radiation of an ytterbium nanosecond pulsed all-fiber laser in a type-I phase-matched LiB(3)O(5) (LBO) crystal where originally orthogonal polarization planes of the fundamental and second harmonic beams are aligned by an optically active quartz crystal. 8 W of ultraviolet light at 355 nm were achieved with 40% conversion efficiency from 1064 nm radiation. The conversion efficiency obtained in a type-I phase-matched LBO THG crystal was 1.6 times higher than the one achieved in a type-II LBO crystal at similar experimental conditions. In comparison to half-wave plates traditionally used for polarization alignment the optically active quartz crystal has much lower temperature dependence and requires simpler optical alignment.

  18. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method

    Directory of Open Access Journals (Sweden)

    Ningning Lin

    2016-11-01

    Full Text Available In this paper, the influence of temperature on quartz crystal microbalance (QCM sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of −3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.

  19. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method.

    Science.gov (United States)

    Lin, Ningning; Meng, Xiaofeng; Nie, Jing

    2016-11-18

    In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of -3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.

  20. Acoustic loss and frequency stability studies of gamma- and proton-irradiated alpha-quartz crystal resonators

    International Nuclear Information System (INIS)

    Suter, J.J.

    1988-01-01

    This work examines the radiation-induced effects in alpha-quartz crystal resonators and distinguishes the various acoustic losses responsible for the frequency susceptibility over these dose ranges. Simulation of low-earth-orbit proton radiation was accomplished with protons from the Harvard University Cyclotron using a novel proton-beam modulator, which was designed to emulate a 10-120 MeV proton spectrum for the radiation susceptibility and acoustic-loss studies on AT quartz resonators. Quartz resonators having aluminum defect center concentrations between 0.01 and 19 ppm experienced proton-induced frequency shifts not correlated to their aluminum impurity content. It was also found that AT quartz resonators of the electrode-less BVA design experienced the smallest frequency shifts. Experiments conducted with 1.25-MeV gamma rays from a cobalt 60 source demonstrated identical frequency shifts in quartz, indicating that the energy losses of gamma rays and protons in quartz over the examined dose and energy ranges were similar. Acoustic-loss measurements conducted over the 0.3-70 K range revealed that the phonon-phonon and two-level energy excitation peaks near 20 and 5 K, respectively, were not affected by proton or cobalt 60 radiation

  1. A different point of view on the sensitivity of quartz crystal microbalance sensors

    International Nuclear Information System (INIS)

    Arnau, Antonio; Montagut, Yeison; García, José V; Jiménez, Yolanda

    2009-01-01

    In this paper, the sensitivity of a quartz crystal microbalance (QCM) sensor is analysed and discussed in terms of the phase change versus the surface mass change, instead of the classical sensitivity in terms of the resonant frequency change derived from the well-known Sauerbrey equation. The detection sensitivity derived from the Sauerbrey equation is a theoretical detection capability in terms of the frequency change versus the mass change, which increases with the square of frequency. However, when a specific application and measuring system are considered, the detection capability of the QCM sensor must be considered from a different point of view. A new equation is obtained, Δψ ≅ −Δm c /(m q + m L ), which quantifies the phase shift, Δψ, of a fixed frequency signal corresponding to the series resonant frequency of the sensor in a reference state versus a change in the coating mass, Δm c ; m q = η q π/2v q , where η q is the loss viscosity of the unperturbed sensor and v q is the wave propagation speed in quartz, is a parameter which only depends on the physical parameters of the unperturbed resonator and fixes the maximum sensitivity of the sensor and m L = ρ L δ L /2, where ρ L and δ L are, respectively, the liquid density and the wave penetration depth of the wave in the liquid, is the equivalent surface mass density associated with the oscillatory movement of the surface of the sensor in contact with a fluid medium. This equation is an approximate equation around the series resonance frequency of the sensor. The simulation results for 10, 50 and 150 MHz resonance frequency QCM sensors probe its validity. A new electronic system is proposed for QCM biosensor applications based on the equation introduced

  2. Phase transition of pNIPAM grafted on plasma-activated PEO monitored in-situ by quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Heinz, P; Bretagnol, F; Mannelli, I; Gillil, D; Rauscher, H; Rossi, F [European Commission, Joint Research Centre, Institute for Health and Consumer Protection, 21020 Ispra (Vatican City State, Holy See,) (Italy)], E-mail: hubert.rauscher@jrc.it

    2008-03-15

    Thermoresponsive poly(N-isopropylacrylamide) layers were grafted on plasma-activated poly(ethylene oxide)-like substrate. Analysis by ToF-SIMS confirmed the presence of a pNIPAM film, which shows a phase transition temperature at 28 - 32 deg. C with hysteresis, as determined in-situ by quartz crystal microbalance. During the transition, the frequency of the pNIPAM coated quartz sensor exhibits a pronounced and unexpected minimum while the dissipation changes monotonously. This peculiar behaviour is explained by temporary formation of water-rich regions, which may cause delayed release and uptake of water during the collapse and re-swelling of the layer.

  3. Phase transition of pNIPAM grafted on plasma-activated PEO monitored in-situ by quartz crystal microbalance

    International Nuclear Information System (INIS)

    Heinz, P; Bretagnol, F; Mannelli, I; Gillil, D; Rauscher, H; Rossi, F

    2008-01-01

    Thermoresponsive poly(N-isopropylacrylamide) layers were grafted on plasma-activated poly(ethylene oxide)-like substrate. Analysis by ToF-SIMS confirmed the presence of a pNIPAM film, which shows a phase transition temperature at 28 - 32 deg. C with hysteresis, as determined in-situ by quartz crystal microbalance. During the transition, the frequency of the pNIPAM coated quartz sensor exhibits a pronounced and unexpected minimum while the dissipation changes monotonously. This peculiar behaviour is explained by temporary formation of water-rich regions, which may cause delayed release and uptake of water during the collapse and re-swelling of the layer

  4. Improvement of the thickness distribution of a quartz crystal wafer by numerically controlled plasma chemical vaporization machining

    International Nuclear Information System (INIS)

    Shibahara, Masafumi; Yamamura, Kazuya; Sano, Yasuhisa; Sugiyama, Tsuyoshi; Endo, Katsuyoshi; Mori, Yuzo

    2005-01-01

    To improve the thickness uniformity of thin quartz crystal wafer, a new machining process that utilizes an atmospheric pressure plasma was developed. In an atmospheric pressure plasma process, since the kinetic energy of ions that impinge to the wafer surface is small and the density of the reactive species is large, high-efficiency machining without damage is realized, and the thickness distribution is corrected by numerically controlled scanning of the quartz wafer to the localized high-density plasma. By using our developed machining process, the thickness distribution of an AT cut wafer was improved from 174 nm [peak to valley (p-v)] to 67 nm (p-v) within 94 s. Since there are no unwanted spurious modes in the machined quartz wafer, it was proved that the developed machining method has a high machining efficiency without any damage

  5. Preparation and characterization of ethylenediamine and cysteamine plasma polymerized films on piezoelectric quartz crystal surfaces for a biosensor

    International Nuclear Information System (INIS)

    Mutlu, Selma; Coekeliler, Dilek; Shard, Alex; Goktas, Hilal; Ozansoy, Berna; Mutlu, Mehmet

    2008-01-01

    This paper describes a method for the modification of quartz crystal surfaces to be used as a transducer in biosensors that allow recognition and quantification of certain biomolecules (antibodies, enzymes, proteins, etc). Quartz crystal sensors were modified by a plasma based electron beam generator in order to detect the level of the toxin histamine within biological liquids (blood, serum) and food (wine, cheese, fish etc.). Cysteamine and ethylenediamine were used as precursors in the plasma. After each modification step, the layers on the quartz crystal were characterized by frequency measurements. Modified surfaces were also characterized by contact angle, X-ray photoelectron spectroscopy and atomic force microscopy to determine the physical and chemical characteristics of the surfaces after each modification. Finally, the performance of the sensors were tested by the response to histamine via frequency shifts. The frequency shifts of the sensors prepared by plasma polymerization of ethylenediamine and cysteamine were approximately 3230 Hz and 5630 Hz, respectively, whereas the frequency change of the unmodified crystal surface was around 575 Hz

  6. Fundamental study on dissolution behavior of poly(methyl methacrylate) by quartz crystal microbalance

    Science.gov (United States)

    Konda, Akihiro; Yamamoto, Hiroki; Yoshitake, Shusuke; Kozawa, Takahiro

    2016-03-01

    Ionizing radiations such as extreme ultraviolet (EUV) and electron beam (EB) are the most promising exposure source for next-generation lithographic technology. In the realization of high resolution lithography, it is necessary for resist materials to improve the trade-off relationship among sensitivity, resolution, and line width roughness (LWR). In order to overcome them, it is essential to understand basic chemistry of resist matrices in resist processes. In particular, the dissolution process of resist materials is a key process. Therefore, it is essential for next-generation resist design for ionizing radiation to clarify the dissolution behavior of the resist film into developer. However, the details in dissolution process of EUV and EB resist films have not been investigated thus far. In this study, main chain scission and dissolution behavior of poly(methyl methacrylate) (PMMA) as main chain scission type resist was investigated using quartz crystal microbalance (QCM) method and gel permeation chromatography (GPC) in order to understand the relationship between the degree of PMMA degradation and dissolution behavior. The relationship between the molecular weight after irradiation and the swelling behavior was clarified.

  7. Study of quartz crystal microbalance NO2 sensor coated with sputtered indium tin oxide film

    Science.gov (United States)

    Georgieva, V.; Aleksandrova, M.; Stefanov, P.; Grechnikov, A.; Gadjanova, V.; Dilova, T.; Angelov, Ts

    2014-12-01

    A study of NO2 gas sorption ability of thin indium tin oxide (ITO) deposited on 16 MHz quartz crystal microbalance (QCM) is presented. ITO films are grown by RF sputtering of indium/tin target with weight proportion 95:5 in oxygen environment. The ITO films have been characterized by X-ray photoelectron spectroscopy measurements. The ITO surface composition in atomic % is defined to be: In-40.6%, Sn-4.3% and O-55%. The thickness and refractive index of the films are determined by ellipsometric method. The frequency shift of QCM-ITO is measured at different NO2 concentrations. The QCM-ITO system becomes sensitive at NO2 concentration >= 500 ppm. The sorbed mass for each concentration is calculated according the Sauerbrey equation. The results indicated that the 1.09 ng of the gas is sorbed into 150 nm thick ITO film at 500 ppm NO2 concentration. When the NO2 concentration increases 10 times the calculated loaded mass is 5.46 ng. The sorption process of the gas molecules is defined as reversible. The velocity of sorbtion /desorption processes are studied, too. The QCM coated with thin ITO films can be successfully used as gas sensors for detecting NO2 in the air at room temperature.

  8. Study of quartz crystal microbalance NO2 sensor coated with sputtered indium tin oxide film

    International Nuclear Information System (INIS)

    Georgieva, V; Gadjanova, V; Angelov, Ts; Aleksandrova, M; Acad. Georgi Bonchev str.bl. 11, 1113, Sofia (Bulgaria))" data-affiliation=" (Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, Acad. Georgi Bonchev str.bl. 11, 1113, Sofia (Bulgaria))" >Stefanov, P; Acad. Georgi Bonchev str.bl. 11, 1113, Sofia (Bulgaria))" data-affiliation=" (Institute of General and Inorganic Chemistry, Bulgarian Academy of Sciences, Acad. Georgi Bonchev str.bl. 11, 1113, Sofia (Bulgaria))" >Dilova, T; Grechnikov, A

    2014-01-01

    A study of NO 2 gas sorption ability of thin indium tin oxide (ITO) deposited on 16 MHz quartz crystal microbalance (QCM) is presented. ITO films are grown by RF sputtering of indium/tin target with weight proportion 95:5 in oxygen environment. The ITO films have been characterized by X-ray photoelectron spectroscopy measurements. The ITO surface composition in atomic % is defined to be: In-40.6%, Sn-4.3% and O-55%. The thickness and refractive index of the films are determined by ellipsometric method. The frequency shift of QCM-ITO is measured at different NO 2 concentrations. The QCM-ITO system becomes sensitive at NO 2 concentration ≥ 500 ppm. The sorbed mass for each concentration is calculated according the Sauerbrey equation. The results indicated that the 1.09 ng of the gas is sorbed into 150 nm thick ITO film at 500 ppm NO 2 concentration. When the NO 2 concentration increases 10 times the calculated loaded mass is 5.46 ng. The sorption process of the gas molecules is defined as reversible. The velocity of sorbtion /desorption processes are studied, too. The QCM coated with thin ITO films can be successfully used as gas sensors for detecting NO 2 in the air at room temperature

  9. Gold clusters sliding on graphite: a possible quartz crystal microbalance experiment?

    International Nuclear Information System (INIS)

    Pisov, S; Tosatti, E; Tartaglino, U; Vanossi, A

    2007-01-01

    A large measured two-dimensional (2D) diffusion coefficient of gold nanoclusters on graphite has been known experimentally and theoretically for about a decade. When subjected to a lateral force, these clusters should slide with an amount of friction that can be measured. We examine the hypothetical possibility of measuring by quartz crystal microbalance (QCM) the phononic sliding friction of gold clusters in the size range around 250 atoms on a graphite substrate between 300 and 600 K. Assuming the validity of Einstein's relations of ordinary Brownian motion and making use of the experimentally available activated behaviour of the diffusion coefficients, we can predict the sliding friction and slip times as a function of temperature. It is found that a prototypical deposited gold cluster could yield slip times at the standard measurable size of 10 -9 s for temperatures around 450-500 K, or 200 0 C. Since gold nanoclusters may also melt at around these temperatures, QCM could offer the additional chance of observing this phenomenon through a frictional change

  10. Scanning tunneling microscope-quartz crystal microbalance study of temperature gradients at an asperity contact.

    Science.gov (United States)

    Pan, L; Krim, J

    2013-01-01

    Investigations of atomic-scale friction frequently involve setups where a tip and substrate are initially at different temperatures. The temperature of the sliding interface upon contact has thus become a topic of interest. A method for detecting initial tip-sample temperature differences at an asperity contact is described, which consists of a scanning tunneling microscope (STM) tip in contact with the surface electrode of a quartz crystal microbalance (QCM). The technique makes use of the fact that a QCM is extremely sensitive to abrupt changes in temperature. In order to demonstrate the technique's capabilities, QCM frequency shifts were recorded for varying initial tip-substrate temperature differences as an STM tip was brought into and out of contact. The results are interpreted within the context of a recent model for thermal heat conduction at an asperity contact, and it is concluded that the transient frequency response is attributable to small changes in temperature close to the region of contact rather than a change in the overall temperature of the QCM itself. For the assumed model parameters, the results moreover reveal substantial temperature discontinuities at the boundary between the tip and the sample, for example, on the order of 10-15 °C for initial temperature differences of 20 °C.

  11. Transient effects during erosion of WN by deuterium ions studied with the quartz crystal microbalance technique

    Energy Technology Data Exchange (ETDEWEB)

    Berger, Bernhard M., E-mail: berger@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Stadlmayr, Reinhard [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Meisl, Gerd [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Čekada, Miha [Jožef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Eisenmenger-Sittner, Christoph [Institute of Solid State Physics, TU Wien, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria); Schwarz-Selinger, Thomas [Max-Planck-Institut für Plasmaphysik, Boltzmannstraße 2, 85748 Garching (Germany); Aumayr, Friedrich, E-mail: aumayr@iap.tuwien.ac.at [Institute of Applied Physics, TU Wien, Fusion@ÖAW, Wiedner Hauptstr. 8-10, 1040 Vienna (Austria)

    2016-09-01

    Transient effects during erosion of polycrystalline tungsten-nitride (WN) films by mono-energetic deuterium projectiles are studied using a quartz crystal microbalance technique. The evolution of the mass removal rate of a 360 nm thin WN film under 500 eV/D and 1000 eV/D bombardment is investigated at a temperature of 465 K in situ and in real-time as a function of the deuterium fluence. The measurements are performed at a typical flux of 10{sup 18} m{sup −2} s{sup −1}. A strong dependency of the observed mass change rate on the deuterium fluence is found. The mass loss is initially higher than for pure tungsten (W) and drops with fluence, finally reaching the same steady state value as for pure W sputtering. Steady state surface conditions are obtained at a fluence of about 0.2 × 10{sup 23} D/m{sup 2} for 500 eV/D and 0.6 × 10{sup 23} D/m{sup 2} for 1000 eV/D. SDTrimSP simulations indicate a preferential removal of N and a corresponding W enrichment of the surface.

  12. Protein Adsorption to Titanium and Zirconia Using a Quartz Crystal Microbalance Method

    Directory of Open Access Journals (Sweden)

    You Kusakawa

    2017-01-01

    Full Text Available Protein adsorption onto titanium (Ti or zirconia (ZrO2 was evaluated using a 27 MHz quartz crystal microbalance (QCM. As proteins, fibronectin (Fn, a cell adhesive protein, and albumin (Alb, a cell adhesion-inhibiting protein, were evaluated. The Ti and ZrO2 sensors for QCM were characterized by atomic force microscopy and electron probe microanalysis observation, measurement of contact angle against water, and surface roughness. The amounts of Fn and Alb adsorbed onto the Ti and ZrO2 sensors and apparent reaction rate were obtained using QCM measurements. Ti sensor showed greater adsorption of Fn and Alb than the ZrO2 sensor. In addition, amount of Fn adsorbed onto the Ti or ZrO2 sensors was higher than that of Alb. The surface roughness and hydrophilicity of Ti or ZrO2 may influence the adsorption of Fn or Alb. With regard to the adsorption rate, Alb adsorbed more rapidly than Fn onto Ti. Comparing Ti and ZrO2, Alb adsorption rate to Ti was faster than that to ZrO2. Fn adsorption will be effective for cell activities, but Alb adsorption will not. QCM method could simulate in vivo Fn and Alb adsorption to Ti or ZrO2.

  13. Quantitative analyses of Streptococcus mutans biofilms with quartz crystal microbalance, microjet impingement and confocal microscopy.

    Science.gov (United States)

    Kreth, J; Hagerman, E; Tam, K; Merritt, J; Wong, D T W; Wu, B M; Myung, N V; Shi, W; Qi, F

    2004-10-01

    Microbial biofilm formation can be influenced by many physiological and genetic factors. The conventional microtiter plate assay provides useful but limited information about biofilm formation. With the fast expansion of the biofilm research field, there are urgent needs for more informative techniques to quantify the major parameters of a biofilm, such as adhesive strength and total biomass. It would be even more ideal if these measurements could be conducted in a real-time, non-invasive manner. In this study, we used quartz crystal microbalance (QCM) and microjet impingement (MJI) to measure total biomass and adhesive strength, respectively, of S. mutans biofilms formed under different sucrose concentrations. In conjunction with confocal laser scanning microscopy (CLSM) and the COMSTAT software, we show that sucrose concentration affects the biofilm strength, total biomass, and architecture in both qualitative and quantitative manners. Our data correlate well with previous observations about the effect of sucrose on the adherence of S. mutans to the tooth surface, and demonstrate that QCM is a useful tool for studying the kinetics of biofilm formation in real time and that MJI is a sensitive, easy-to-use device to measure the adhesive strength of a biofilm.

  14. Biomimetic Receptors for Bioanalyte Detection by Quartz Crystal Microbalances — From Molecules to Cells

    Directory of Open Access Journals (Sweden)

    Usman Latif

    2014-12-01

    Full Text Available A universal label-free detection of bioanalytes can be performed with biomimetic quartz crystal microbalance (QCM coatings prepared by imprinting strategies. Bulk imprinting was used to detect the endocrine disrupting chemicals (EDCs known as estradiols. The estrogen 17β-estradiol is one of the most potent EDCs, even at very low concentrations. A highly sensitive, selective and robust QCM sensor was fabricated for real time monitoring of 17β-estradiol in water samples by using molecular imprinted polyurethane. Optimization of porogen (pyrene and cross-linker (phloroglucinol levels leads to improved sensitivity, selectivity and response time of the estradiol sensor. Surface imprinting of polyurethane as sensor coating also allowed us to generate interaction sites for the selective recognition of bacteria, even in a very complex mixture of interfering compounds, while they were growing from their spores in nutrient solution. A double molecular imprinting approach was followed to transfer the geometrical features of natural bacteria onto the synthetic polymer to generate biomimetic bacteria. The use of biomimetic bacteria as template makes it possible to prepare multiple sensor coatings with similar sensitivity and selectivity. Thus, cell typing, e.g., differentiation of bacteria strains, bacteria growth profile and extent of their nutrition, can be monitored by biomimetic mass sensors. Obviously, this leads to controlled cell growth in bioreactors.

  15. Single-pulse and burst-mode ablation of gold films measured by quartz crystal microbalance

    Science.gov (United States)

    Andrusyak, Oleksiy G.; Bubelnik, Matthew; Mares, Jeremy; McGovern, Theresa; Siders, Craig W.

    2005-02-01

    Femtosecond ablation has several distinct advantages: the threshold energy fluence for the onset of damage and ablation is orders of magnitude less than for traditional nanosecond laser machining, and by virtue of the rapid material removal of approximately an optical penetration depth per pulse, femtosecond machined cuts can be cleaner and more precise than those made with traditional nanosecond or longer pulse lasers. However, in many materials of interest, especially metals, this limits ablation rates to 10-100 nm/pulse. We present the results of using multiple pulse bursts to significantly increase the per-burst ablation rate compared to a single pulse with the same integrated energy, while keeping the peak intensity of each individual pulse below the air ionization limit. Femtosecond ablation with pulses centered at 800-nm having integrated energy of up to 30 mJ per pulse incident upon thin gold films was measured via resonance frequency shifts in a gold-electrode-coated quartz-crystal oscillator. Measurements were performed using Michelson-interferometer-based burst generators, with up to 2 ns pulse separations, as well as pulse shaping by programmable acousto-optic dispersive filter (Dazzler from FastLite) with up to 2 ps pulse separations.

  16. Quartz crystal microbalance (QCM) affinity biosensor for genetically modified organisms (GMOs) detection.

    Science.gov (United States)

    Mannelli, Ilaria; Minunni, Maria; Tombelli, Sara; Mascini, Marco

    2003-03-01

    A DNA piezoelectric sensor has been developed for the detection of genetically modified organisms (GMOs). Single stranded DNA (ssDNA) probes were immobilised on the sensor surface of a quartz crystal microbalance (QCM) device and the hybridisation between the immobilised probe and the target complementary sequence in solution was monitored. The probe sequences were internal to the sequence of the 35S promoter (P) and Nos terminator (T), which are inserted sequences in the genome of GMOs regulating the transgene expression. Two different probe immobilisation procedures were applied: (a) a thiol-dextran procedure and (b) a thiol-derivatised probe and blocking thiol procedure. The system has been optimised using synthetic oligonucleotides, which were then applied to samples of plasmidic and genomic DNA isolated from the pBI121 plasmid, certified reference materials (CRM), and real samples amplified by the polymerase chain reaction (PCR). The analytical parameters of the sensor have been investigated (sensitivity, reproducibility, lifetime etc.). The results obtained showed that both immobilisation procedures enabled sensitive and specific detection of GMOs, providing a useful tool for screening analysis in food samples.

  17. A hybrid humidity sensor using optical waveguides on a quartz crystal microbalance

    International Nuclear Information System (INIS)

    Shinbo, Kazunari; Otuki, Shunya; Kanbayashi, Yuichi; Ohdaira, Yasuo; Baba, Akira; Kato, Keizo; Kaneko, Futao; Miyadera, Nobuo

    2009-01-01

    In this study, slab and ridge optical waveguides (OWGs) made of fluorinated polyimides were deposited on a quartz crystal microbalance (QCM), and hybrid sensors using OWG spectroscopy and the QCM technique were prepared. Polyvinyl alcohol (PVA) film with CoCl 2 was deposited on the OWGs, and the characteristics of humidity sensing were investigated. A prism coupler was used to enter a He-Ne laser beam (λ = 632.8 nm) to the slab OWG. The output light intensity markedly changed due to chromism of the CoCl 2 as a result of humidity sorption, and this change was dependent on the incident angle of the laser beam to the slab OWG. During the measurement of output light, the QCM frequency was simultaneously monitored. The humidity dependence of the sensor with the slab OWG was also investigated in the range from 15 to 85%. For the sensor with the ridge OWG, white light was entered by butt-coupling, and the characteristics of humidity sensing were investigated by observing the output light spectrum and the QCM frequency.

  18. Frequency-shift vs phase-shift characterization of in-liquid quartz crystal microbalance applications

    International Nuclear Information System (INIS)

    Montagut, Y. J.; Garcia, J. V.; Jimenez, Y.; Arnau, A.; March, C.; Montoya, A.

    2011-01-01

    The improvement of sensitivity in quartz crystal microbalance (QCM) applications has been addressed in the last decades by increasing the sensor fundamental frequency, following the increment of the frequency/mass sensitivity with the square of frequency predicted by Sauerbrey. However, this sensitivity improvement has not been completely transferred in terms of resolution. The decrease of frequency stability due to the increase of the phase noise, particularly in oscillators, made impossible to reach the expected resolution. A new concept of sensor characterization at constant frequency has been recently proposed. The validation of the new concept is presented in this work. An immunosensor application for the detection of a low molecular weight contaminant, the insecticide carbaryl, has been chosen for the validation. An, in principle, improved version of a balanced-bridge oscillator is validated for its use in liquids, and applied for the frequency shift characterization of the QCM immunosensor application. The classical frequency shift characterization is compared with the new phase-shift characterization concept and system proposed.

  19. Adsorption of quantum dots onto polymer and Gemini surfactant films: a quartz crystal microbalance study.

    Science.gov (United States)

    Alejo, T; Merchán, M D; Velázquez, M M

    2014-08-26

    We used quartz crystal microbalance with dissipation to study the mechanical properties, the kinetics of adsorption, and the amount of CdSe quantum dots (QDs) adsorbed onto a SiO2 sensor, referred as bare sensor, onto the sensor modified with a film of the polymer poly(maleic anhydride-alt-1-octadecene), PMAO, or with a film of the Gemini surfactant ethyl-bis(dimethyl octadecyl ammonium bromide), abbreviated as 18-2-18. Results showed that when the sensor is coated with polymer or surfactant molecules, the coverage increases compared with that obtained for the bare sensor. On the other hand, rheological properties and kinetics of adsorption of QDs are driven by QD nanoparticles. Thus, the QD films present elastic behavior, and the elasticity values are independent of the molecule used as coating and similar to the elasticity value obtained for QDs films on the bare sensor. The QD adsorption is a two-step mechanism in which the fastest process is attributed to the QD adsorption onto the solid substrate and the slowest one is ascribed to rearrangement movements of the nanoparticles adsorbed at the surface.

  20. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    International Nuclear Information System (INIS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-01-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (−90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range

  1. SHORT COMMUNICATION: Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena

    Science.gov (United States)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Byung-Il

    2007-10-01

    Distinguishing between a supercooled dew and frost below 0 °C in dew/frost-point measurements is an important and challenging problem that has not yet been completely solved. This study presents a new method for the recognition of a supercooled dew in a dew/frost-point sensor. A quartz crystal microbalance (QCM) sensor was used as a dew/frost-point sensor to detect a dew and a supercooled dew as well as frost. The slip phenomenon occurring at an interface between the water droplet and the surface of the quartz crystal resonator of the QCM sensor gives a simple and accurate way of distinguishing between a supercooled dew and frost below 0 °C. This method can give a highly accurate measurement of the dew or the frost point without misreading in the dew-point sensor at temperatures below 0 °C.

  2. Quartz Crystal Microbalance with Dissipation (QCM-D) studies of the viscoelastic response from a continuously growing grafted polyelectrolyte layer

    DEFF Research Database (Denmark)

    Dunér, Gunnar; Thormann, Esben; Dedinaite, Andra

    2013-01-01

    Poly(acrylic acid) was grown from substrates by photopolymerization, and the grafting process was monitored in situ by Quartz Crystal Microbalance with Dissipation (QCM-D) measurements in a 1:1 v/v mixture of water/ethanol. The polymerization process was monitored into the thick film region, wher...... that should be considered when investigating small changes in thick films used in e.g. sensor applications. © 2013 Elsevier Inc....

  3. Preparation and characterization of PTFE coating in new polymer quartz piezoelectric crystal sensor for testing liquor products

    International Nuclear Information System (INIS)

    Gu Yu; Li Qiang

    2015-01-01

    A new method was developed based on the electron beam vacuum dispersion (EBVD) technology to prepare the PTFE polymer coating of the new polymer quartz piezoelectric crystal sensor for testing liquor products. The new method was applied in the new EBVD equipment which we designed. A real-time system monitoring the polymer coating’s thickness was designed for the new EBVD equipment according to the quartz crystal microbalance (QCM) principle, playing an important role in preparing stable and uniform PTFE polymer coatings of the same thickness. 30 pieces of PTFE polymer coatings on the surface of the quartz crystal basis were prepared with the PTFE polymer ultrafine powder (purity ≥ 99.99%) as the starting material. We obtained 30 pieces of new PTFE polymer sensors. By using scanning electron microscopy (SEM), the structure of the PTFE polymer coating’s column clusters was studied. One sample from the 30 pieces of new PTFE polymer sensors was analysed by SEM in four scales, i.e., 400×, 1000×, 10000×, and 25000×. It was shown that under the condition of high bias voltage and low bias current, uniformly PTFE polymer coating could be achieved, which indicates that the new EBVD equipment is suitable for mass production of stable and uniform polymer coating. (paper)

  4. Hexamethyldisiloxane thin films as sensitive coating for quartz crystal microbalance based volatile organic compounds sensors

    International Nuclear Information System (INIS)

    Boutamine, M.; Bellel, A.; Sahli, S.; Segui, Y.; Raynaud, P.

    2014-01-01

    Hexamethyldisiloxane (HMDSO) thin films coated quartz crystal microbalance (QCM) electrodes have been characterized for the detection of volatile organic compounds (VOCs). The sensitive coatings were plasma polymerized in pure vapor of HMDSO and HMDSO/O 2 mixture. The sensor sensitivity was evaluated by monitoring the frequency shift (∆f) of the coated QCM electrode exposed to different concentrations of VOC vapors, such as ethanol, methanol, benzene and chloroform. The isotherm response characteristics showed good reproducibility and reversibility. For all types of analyte, ∆f were found to be linearly correlated with the concentration of VOC vapor. It was shown that it is possible to tune the chemical affinity of the sensor by changing the oxygen ratio in the deposition gas mixture. Contact angle measurements (CA), attenuated total reflectance-Fourier transform infrared (ATR-FTIR) spectroscopy, atomic force microscopy (AFM) and scanning electron microscopy (SEM) were used to study surface wettability, chemical composition and surface morphology of the coated QCM electrodes. ATR-FTIR analysis showed the presence of methyl groups around 840 cm −1 due to Si-(CH 3 ) 3 rocking vibration making the elaborated sensor surface hydrophobic. When the coating is performed in HMDSO/O 2 mixture, AFM and SEM images showed an increase in the effective specific surface area of the sensor due to the increase in surface roughness. Surface morphology combined with chemical composition significantly affects the sensitivity of the QCM-based sensor. - Highlights: • Hexamethyldisiloxane layers were evaluated for volatile organic compounds detection. • The kinetic response of the sensor showed good reproducibility and reversibility. • Hydrophobic coating and high specific surface area increase the sensor sensitivity. • Sensor affinity can be controlled by controlling oxygen proportion in the mixture

  5. Use of quartz crystal nanobalance to study the binding and stabilization of albumin and doxycycline on a thin layer of hydroxyapatite

    Science.gov (United States)

    Victor, Sunita Prem; Sharma, Chandra P.; Sreenivasan, K.

    2011-12-01

    This study reports the use of quartz crystal nanobalance (QCN) to study the adsorption of two model molecules namely albumin and doxycycline by hydroxyapatite (HA). The work focuses on the deposition of a stable coating of HA on the quartz crystal, modification of the coating using doxycycline and its subsequent effects on albumin adsorption. The uniformity and thickness of the HA coating has been studied using atomic force microscopy (AFM). The functional groups to ascertain the presence of the selected moieties have been characterized by Raman spectroscopy. The results indicate that the mass of albumin deposited on the surface of the HA coated quartz crystal functionalized with doxycycline shows a substantial increase when compared to the standard HA coated quartz crystal. The adsorbed albumin has also been found to be retained for an enhanced period of time. This surface immobilization of doxycycline and subsequent albumin adsorption seem to be a promising approach to confer biomaterials with antithrombogenic and antibacterial surfaces.

  6. Use of quartz crystal nanobalance to study the binding and stabilization of albumin and doxycycline on a thin layer of hydroxyapatite

    Energy Technology Data Exchange (ETDEWEB)

    Victor, Sunita Prem [Biosurface Technology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum 695012, Kerala (India); Sharma, Chandra P., E-mail: sharmacp@sctmist.ac.in [Biosurface Technology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum 695012, Kerala (India); Sreenivasan, K. [Biosurface Technology Division, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum 695012, Kerala (India); Laboratory for Polymer Analysis, Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences and Technology, Trivandrum 695012, Kerala (India)

    2011-12-15

    This study reports the use of quartz crystal nanobalance (QCN) to study the adsorption of two model molecules namely albumin and doxycycline by hydroxyapatite (HA). The work focuses on the deposition of a stable coating of HA on the quartz crystal, modification of the coating using doxycycline and its subsequent effects on albumin adsorption. The uniformity and thickness of the HA coating has been studied using atomic force microscopy (AFM). The functional groups to ascertain the presence of the selected moieties have been characterized by Raman spectroscopy. The results indicate that the mass of albumin deposited on the surface of the HA coated quartz crystal functionalized with doxycycline shows a substantial increase when compared to the standard HA coated quartz crystal. The adsorbed albumin has also been found to be retained for an enhanced period of time. This surface immobilization of doxycycline and subsequent albumin adsorption seem to be a promising approach to confer biomaterials with antithrombogenic and antibacterial surfaces.

  7. Use of quartz crystal nanobalance to study the binding and stabilization of albumin and doxycycline on a thin layer of hydroxyapatite

    International Nuclear Information System (INIS)

    Victor, Sunita Prem; Sharma, Chandra P.; Sreenivasan, K.

    2011-01-01

    This study reports the use of quartz crystal nanobalance (QCN) to study the adsorption of two model molecules namely albumin and doxycycline by hydroxyapatite (HA). The work focuses on the deposition of a stable coating of HA on the quartz crystal, modification of the coating using doxycycline and its subsequent effects on albumin adsorption. The uniformity and thickness of the HA coating has been studied using atomic force microscopy (AFM). The functional groups to ascertain the presence of the selected moieties have been characterized by Raman spectroscopy. The results indicate that the mass of albumin deposited on the surface of the HA coated quartz crystal functionalized with doxycycline shows a substantial increase when compared to the standard HA coated quartz crystal. The adsorbed albumin has also been found to be retained for an enhanced period of time. This surface immobilization of doxycycline and subsequent albumin adsorption seem to be a promising approach to confer biomaterials with antithrombogenic and antibacterial surfaces.

  8. Frequency shift of a crystal quartz resonator in thickness-shear modes induced by an array of hemispherical material units.

    Science.gov (United States)

    Yuantai Hu; Huiliang Hu; Bin Luo; Huan Xue; Jiemin Xie; Ji Wang

    2013-08-01

    A two-dimensional model was established to study the dynamic characteristics of a quartz crystal resonator with the upper surface covered by an array of hemispherical material units. A frequency-dependent equivalent mass ratio was proposed to simulate the effect of the covered units on frequency shift of the resonator system. It was found that the equivalent mass ratio alternately becomes positive or negative with change of shear modulus and radius of each material unit, which indicates that the equivalent mass ratio is strongly related to the vibration mode of the covered loadings. The further numerical results show the cyclical feature in the relationship of frequency shift and shear modulus/radius as expected. The solutions are useful in the analysis of frequency stability of quartz resonators and acoustic wave sensors.

  9. Humidity scanning quartz crystal microbalance with dissipation monitoring setup for determination of sorption-desorption isotherms and rheological changes

    Energy Technology Data Exchange (ETDEWEB)

    Björklund, Sebastian, E-mail: sebastianbjorklund@gmail.com; Kocherbitov, Vitaly [Department of Biomedical Science, Faculty of Health and Society, Malmö University, Malmö (Sweden); Biofilms—Research Center for Biointerfaces, Malmö University, Malmö (Sweden)

    2015-05-15

    A new method to determine water sorption-desorption isotherms with high resolution in the complete range of water activities (relative humidities) is presented. The method is based on quartz crystal microbalance with dissipation monitoring (QCM-D). The QCM-D is equipped with a humidity module in which the sample film is kept in air with controlled humidity. The experimental setup allows for continuous scanning of the relative humidity from either dry to humid conditions or vice versa. The amount of water sorbed or desorbed from the sample is determined from the resonance frequencies of the coated quartz sensor, via analysis of the overtone dependence. In addition, the method allows for characterization of hydration induced changes of the rheological properties from the dissipation data, which is closely connected to the viscoelasticity of the film. The accuracy of the humidity scanning setup is confirmed in control experiments. Sorption-desorption isotherms of pig gastric mucin and lysozyme, obtained by the new method, show good agreement with previous results. Finally, we show that the deposition technique used to coat the quartz sensor influences the QCM-D data and how this issue can be used to obtain further information on the effect of hydration. In particular, we demonstrate that spin-coating represents an attractive alternative to obtain sorption-desorption isotherms, while drop-coating provides additional information on changes of the rheological properties during hydration.

  10. Adsorption effectiveness of β-lactoglobulin onto gold surface determined by quartz crystal microbalance.

    Science.gov (United States)

    Jachimska, B; Świątek, S; Loch, J I; Lewiński, K; Luxbacher, T

    2018-06-01

    Bovine β-lactoglobulin (LGB) is a transport protein that can bind to its structure hydrophobic bioactive molecules. Due to the lack of toxicity, high stability and pH-dependent molecular binding mechanism, lactoglobulin can be used as a carrier of sparingly soluble drugs. Dynamic light scattering has confirmed LGB's tendency to create oligomeric forms. The hydrodynamic diameter of LGB molecules varies from 4 nm to 6 nm in the pH range of 2-10 and ionic strength I = 0.001-0.15 M, which corresponds to the presence of mono or dimeric LGB forms. The LGB zeta potential varies from 26.5 mV to -33.3 mV for I = 0.01 M and from 13.3 mV to -16 mV for I = 0.15 M in the pH range of 2-10. The isoelectric point is at pH 4.8. As a result of strong surface charge compensation, the maximum effective ionization degree of the LGB molecule is 35% for ionic strength I = 0.01 M and 22% for I = 0.15 M. The effectiveness of adsorption is linked with the properties of the protein, as well as those of the adsorption surface. The functionalization of gold surfaces with β-lactoglobulin (LGB) was studied using a quartz crystal microbalance with energy dissipation monitoring (QCM-D). The effectiveness of LGB adsorption correlates strongly with a charge of gold surface and the zeta potential of the molecule. The greatest value of the adsorbed mass was observed in the pH range in which LGB has a positive zeta potential values, below pH 4.8. This observation shows that electrostatic interactions play a dominant role in LGB adsorption on gold surfaces. Based on the adsorbed mass, protein orientation on gold surfaces was determined. The preferential side-on orientation of LGB molecules observed in the adsorption layer is consistent with the direction of the molecule dipole momentum determined by molecular dynamics simulations of the protein (MD). The use of the QCM-D method also allowed us to determine the effectiveness of adsorption of LGB on gold

  11. New Quartz Crystal Oscillators Using the Current-Feedback Operational Amplifier

    OpenAIRE

    Muhammad Taher Abuelma'atti; Ahmad Al-Ghazwani

    2000-01-01

    New crystal oscillators using the current-feedback operational-amplifier (CFOA) are presented. Each circuit uses one CFOA, a crystal and, at most, five externally connected passive elements. Experimental results are included.

  12. A sensitive molecularly imprinted polymer based quartz crystal microbalance nanosensor for selective determination of lovastatin in red yeast rice.

    Science.gov (United States)

    Eren, Tanju; Atar, Necip; Yola, Mehmet Lütfi; Karimi-Maleh, Hassan

    2015-10-15

    Lovastatin (LOV) is a statin, used to lower cholesterol which has been found as a hypolipidemic agent in commercial red yeast rice. In present study, a sensitive molecular imprinted quartz crystal microbalance (QCM) sensor was prepared by fabricating a self-assembling monolayer formation of allylmercaptane on QCM chip surface for selective determination of lovastatin (LOV) in red yeast rice. To prepare molecular imprinted quartz crystal microbalance (QCM) nanosensor, LOV imprinted poly(2-hydroxyethyl methacrylate-methacryloylamidoaspartic acid) [p(HEMA-MAAsp)] nanofilm was attached on the modified gold surface of QCM chip. The non-modified and improved surfaces were characterized by using contact angle, atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. The imprinted QCM sensor was validated according to the ICH guideline (International Conference on Harmonisation). The linearity range was obtained as 0.10-1.25 nM. The detection limit of the prepared material was calculated as 0.030 nM. The developed QCM nanosensor was successfully used to examine red yeast rice. Furthermore, the stability and repeatability of the prepared QCM nanosensor were studied. The spectacular long-term stability and repeatability of the prepared LOV-imprinted QCM nanosensor make them intriguing for use in QCM sensors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Study on pivot-point vibration of molecular bond-rupture events by quartz crystal microbalance for biomedical diagnostics

    Directory of Open Access Journals (Sweden)

    Yuan YJ

    2012-01-01

    Full Text Available Yong J Yuan, Renjie JiaLaboratory of Biosensing and MicroMechatronics, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, Sichuan, People's Republic of ChinaAbstract: Bond-rupture scanning for biomedical diagnostics is examined using quartz crystal microbalance (QCM experiments and microparticle mechanics modeling calculations. Specific and nonspecific interactions between a microparticle and its binding QCM surface can be distinguished by gradually increasing the amplitude of driving voltage applied to QCM and monitoring its frequency changes. This research proposes a mechanical model of interactions between biological molecules and a QCM substrate surface. The mechanical force required to break a biotin–streptavidin bond was calculated through a one-pivot-point bottom-up vibration model. The bond-rupture force increases with an increase of the microparticle radius, the QCM resonant frequency, and the amplitude of driving voltage applied to the QCM. The significance of the research on biological molecular bond rupture is extremely important in characterizing microbial (such as cells and virus specificity, due to the force magnitude needed to break bonds using a transducer.Keywords: bond rupture, mechanical force, biomolecular binding energy spectra, quartz crystal microbalance (QCM

  14. In-Line Measurement of Water Content in Ethanol Using a PVA-Coated Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Byoung Chul Kim

    2014-01-01

    Full Text Available An in-line device for measuring the water content in ethanol was developed using a polyvinyl alcohol (PVA-coated quartz crystal microbalance. Bio-ethanol is widely used as the replacement of gasoline, and its water content is a key component of its specifications. When the PVA-coated quartz crystal microbalance is contacted with ethanol containing a small amount of water, the water is absorbed into the PVA increasing the load on the microbalance surface to cause a frequency drop. The determination performance of the PVA-coated microbalance is examined by measuring the frequency decreases in ethanol containing 2% to 10% water while the ethanol flows through the measurement device. The measurements indicates that the higher water content is the more the frequency reduction is, though some deviation in the measurements is observed. This indicates that the frequency measurement of an unknown concentration of water in ethanol can be used to determine the water content in ethanol. The PVA coating is examined by microscopy and FTIR (Fourier transform infrared spectroscopy.

  15. Atomic motion of resonantly vibrating quartz crystal visualized by time-resolved X-ray diffraction

    International Nuclear Information System (INIS)

    Aoyagi, Shinobu; Osawa, Hitoshi; Sugimoto, Kunihisa; Fujiwara, Akihiko; Takeda, Shoichi; Moriyoshi, Chikako; Kuroiwa, Yoshihiro

    2015-01-01

    Transient atomic displacements during a resonant thickness-shear vibration of AT-cut α-quartz are revealed by time-resolved X-ray diffraction under an alternating electric field. The lattice strain resonantly amplified by the alternating electric field is ∼10 4 times larger than that induced by a static electric field. The resonantly amplified lattice strain is achieved by fast displacements of oxygen anions and collateral resilient deformation of Si−O−Si angles bridging rigid SiO 4 tetrahedra, which efficiently transduce electric energy into elastic energy

  16. An insight into the adsorption and electrochemical processes occurring during the analysis of copper and lead in wines, using an electrochemical quartz crystal nanobalance.

    Science.gov (United States)

    Yamasaki, Alzira; Oliveira, João A B P; Duarte, Armando C; Gomes, M Teresa S R

    2012-08-30

    Copper and lead in wine were quantified by anodic stripping voltammetry (ASV), performed onto the gold electrode of a piezoelectric quartz crystal. Both current or mass changes could be used as analytical signals, without a statistical difference in the results (α=0.05). However, the plot of mass vs. potential provided an in depth understanding of the electrochemical processes and allowed studying adsorption phenomena. Copper interaction with fructose is an example of a process which was not possible to ignore by observing the mass change on the gold electrode of the piezoelectric quartz crystal. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Solid dispersions of Myricetin with enhanced solubility: Formulation, characterization and crystal structure of stability-impeding Myricetin monohydrate crystals

    Science.gov (United States)

    Mureşan-Pop, M.; Pop, M. M.; Borodi, G.; Todea, M.; Nagy-Simon, T.; Simon, S.

    2017-08-01

    Three solid dispersion forms of Myricetin combined with the Polyvinylpyrrolidone were successfully prepared by spray drying method, and characterized by X-ray powder diffraction, thermal analysis, infrared spectroscopy and optical microscopy. Zeta potential measurements provided indications on solid dispersions stability in aqueous suspension related to their storage at elevated temperature and relative humidity, which depends on the Myricetin load. By increase of Myricetin load, the stability of the solid dispersion is impeded due to growth of Myricetin monohydrate crystals. The amorphous dispersions with 10% and 50% Myricetin load are stable and, compared to pure Myricetin, their aqueous solubility is enhanced by a factor of 47 and 13, respectively. The dispersion with 80% Myricetin load is unstable on storage, and this behavior acts in conjunction with the development of Myricetin monohydrate crystals. Single-crystal X-ray diffraction results obtained for Myricetin monohydrate reveal a structure of an infinite 2D network of hydrogen-bonded molecules involving all six hydroxyl groups of Myricetin. The water molecules are positioned in between the infinite chains, and contribute via H-bonds to robust crystal packing. The calculated needle-like morphology of monohydrate form is in agreement with the optical microscopy results. The study shows that the solid amorphous dispersions with up to 50% Myricetin load are a viable option for achieving substantial solubility improvement of Myricetin, and supports their potential use in pharmaceutical applications.

  18. Application of an Electrochemical Quartz Crystal Microbalance to the study of electrocatalytic films

    Energy Technology Data Exchange (ETDEWEB)

    Gordon, Jr., James S. [Iowa State Univ., Ames, IA (United States)

    1993-09-01

    The EQCM was used to study the deposition and composition of electrodeposited pure PbO2 and Bi-doped PbO2 active toward anodic oxygen-transfer reactions. Within the doped films, Bi is incorporated as Bi+5 in the form of BiO2A, where A is ClO4- or NO3-. For deposition of these 2 materials, changes in hydration between the Au oxide and the depositing film resulted in higher mass-to-charge ratios. XRD and XPS were used to study the films; the rutile structure of PbO2 is retained even with the Bi doping. The EQCM was also used to study the formation and dissolution of Au oxide and preoxide structures formed on the Au substrate electrodes in acidic media. The preoxide structures were AuOH and increased the surface mass. For the formation of stable Au films on quartz wafers, Ti interlayers between Au and quartz was found to be very effective.

  19. Characterization of Bi4Ge3O12 single crystal by impedance spectroscopy

    Directory of Open Access Journals (Sweden)

    Zélia Soares Macedo

    2003-12-01

    Full Text Available Bi4Ge3O12 (bismuth germanate - BGO single crystals were produced by the Czochralski technique and their electrical and dielectric properties were investigated by impedance spectroscopy. The isothermal ac measurements were performed for temperatures from room temperature up to 750 °C, but only the data taken above 500 °C presented a complete semicircle in the complex impedance diagrams. Experimental data were fitted to a parallel RC equivalent circuit, and the electrical conductivity was obtained from the resistivity values. Conductivity values from 5.4 × 10(9 to 4.3 × 10-7 S/cm were found in the temperature range of 500 to 750 °C. This electrical conductivity is thermally activated, following the Arrhenius law with an apparent activation energy of (1.41 ± 0.04 eV. The dielectric properties of BGO single crystal were also studied for the same temperature interval. Permittivity values of 20 ± 2 for frequencies higher than 10³ Hz and a low-frequency dispersion were observed. Both electric and dielectric behavior of BGO are typical of systems in which the conduction mechanism dominates the dielectric response.

  20. Study on pivot-point vibration of molecular bond-rupture events by quartz crystal microbalance for biomedical diagnostics.

    Science.gov (United States)

    Yuan, Yong J; Jia, Renjie

    2012-01-01

    Bond-rupture scanning for biomedical diagnostics is examined using quartz crystal microbalance (QCM) experiments and microparticle mechanics modeling calculations. Specific and nonspecific interactions between a microparticle and its binding QCM surface can be distinguished by gradually increasing the amplitude of driving voltage applied to QCM and monitoring its frequency changes. This research proposes a mechanical model of interactions between biological molecules and a QCM substrate surface. The mechanical force required to break a biotin-streptavidin bond was calculated through a one-pivot-point bottom-up vibration model. The bond-rupture force increases with an increase of the microparticle radius, the QCM resonant frequency, and the amplitude of driving voltage applied to the QCM. The significance of the research on biological molecular bond rupture is extremely important in characterizing microbial (such as cells and virus) specificity, due to the force magnitude needed to break bonds using a transducer.

  1. Determination of thermodynamic parameters for enolization reaction of malonic and metylmalonic acids by using quartz crystal microbalance

    Directory of Open Access Journals (Sweden)

    Minoru Yoshimoto

    2016-06-01

    Full Text Available We investigated the process of a bromination reaction of malonic acid and methylmalonic acid in the Belousov-Zhabotinsky reaction by using a quartz crystal microbalance (QCM. The process involves an enolization reaction as a rate-determining step. We found that, in the step, the variation of Br2 concentration induced an exactly quantitative shift of a resonant frequency of the QCM, based on the change of the surface mass on the QCM and the solution viscosity and density. This new finding enabled us to estimate the reaction rate constants and the thermodynamic parameters of the enolization reaction due to a QCM measurement. The values measured by the QCM were in good agreement with those measured by a UV-spectrophotometer. As a result, we succeeded to develop a new measurement method of a nonlinear chemical reaction.

  2. Tool wear of a single-crystal diamond tool in nano-groove machining of a quartz glass plate

    International Nuclear Information System (INIS)

    Yoshino, Masahiko; Nakajima, Satoshi; Terano, Motoki

    2015-01-01

    Tool wear characteristics of a diamond tool in ductile mode machining are presented in this paper. Nano-groove machining of a quartz glass plate was conducted to examine the tool wear rate of a single-crystal diamond tool. Effects of lubrication on the tool wear rate were also evaluated. A numerical simulation technique was developed to evaluate the tool temperature and normal stress acting on the wear surface. From the simulation results it was found that the tool temperature does not increase during the machining experiment. It is also demonstrated that tool wear is attributed to the abrasive wear mechanism, but the effect of the adhesion wear mechanism is minor in nano-groove machining. It is found that the tool wear rate is reduced by using water or kerosene as a lubricant. (paper)

  3. Real-time mass measurement of dust particles deposited on vessel wall in a divertor simulator using quartz crystal microbalances

    International Nuclear Information System (INIS)

    Tateishi, Mizuki; Koga, Kazunori; Katayama, Ryu; Yamashita, Daisuke; Kamataki, Kunihiro; Seo, Hyunwoong; Itagaki, Naho; Shiratani, Masaharu; Ashikawa, Naoko; Masuzaki, Suguru; Nishimura, Kiyohiko; Sagara, Akio

    2015-01-01

    We are developing a dust monitoring method using quartz crystal microbalances (QCMs) equipped with a dust eliminating filter. Here we report a dust eliminating ratio of the filter and first measurement results of the QCMs in a divertor simulator. The volume of spherical dust in unit area on the filter and QCM under the filter were 2.09 × 10 −9 and 1.22 × 10 −10 m 3 m −2 , respectively. Thus, the dust eliminating ratio of the filter is 94.2%. The QCM without the filter gives deposition rate due to radicals and dust particles, whereas the QCM with the filter gives deposition rate predominantly due to radicals. From the results, we deduce information of mass fraction of dust particles in deposits

  4. Establishing linear solvation energy relationships between VOCs and monolayer-protected gold nanoclusters using quartz crystal microbalance.

    Science.gov (United States)

    Li, Chi-Lin; Lu, Chia-Jung

    2009-08-15

    Linear solvation energy relationships (LSERs) have been recognized as a useful model for investigating the chemical forces behind the partition coefficients between vapor molecules and absorbents. This study is the first to determine the solvation properties of monolayer-protected gold nanoclusters (MPCs) with different surface ligands. The ratio of partition coefficients/MPC density (K/rho) of 18 volatile organic compounds (VOCs) for four different MPCs obtained through quartz crystal microbalance (QCM) experiments were used for the LSER model calculations. LSER modeling results indicate that all MPC surfaces showed a statistically significant (pattraction, 4-methoxythiophenol-capped MPCs can also interact with polar organics (s=1.04). Showing a unique preference for the hydrogen bond basicity of vapors (b=1.11), 2-benzothiazolethiol-capped MPCs provide evidence of an intra-molecular, proton-shift mechanism on surface of nano-gold.

  5. In-Line Measurement of Water Contents in Ethanol Using a Zeolite-Coated Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Byoung Chul Kim

    2015-10-01

    Full Text Available A quartz crystal microbalance (QCM was utilized to measure the water content in ethanol. For the improvement of measurement sensitivity, the QCM was modified by applying zeolite particles on the surface with poly(methyl methacrylate (PMMA binder. The measurement performance was examined with ethanol of 1% to 5% water content in circulation. The experimental results showed that the frequency drop of the QCM was related with the water content though there was some deviation. The sensitivity of the zeolite-coated QCM was sufficient to be implemented in water content determination, and a higher ratio of silicon to aluminum in the molecular structure of the zeolite gave better performance. The coated surface was inspected by microscopy to show the distribution of zeolite particles and PMMA spread.

  6. Effective antibodies immobilization and functionalized nanoparticles in a quartz-crystal microbalance-based immunosensor for the detection of parathion.

    Directory of Open Access Journals (Sweden)

    Bartolomeo Della Ventura

    Full Text Available Biosensor-based detection provides a rapid and low-cost alternative to conventional analytical methods for revealing the presence of the contaminants in water as well as solid matrices. Although important to be detected, small analytes (few hundreds of Daltons are an issue in biosensing since the signal they induce in the transducer, and specifically in a Quartz-Crystal Microbalance, is undetectable. A pesticide like parathion (M = 292 Da is a typical example of contaminant for which a signal amplification procedure is desirable.The ballasting of the analyte by gold nanoparticles has been already applied to heavy target as proteins or bacteria to improve the limit of detection. In this paper, we extend the application of such a method to small analytes by showing that once the working surface of a Quartz-Crystal Microbalance (QCM has been properly functionalized, a limit of detection lower than 1 ppb is reached for parathion. The effective surface functionalization is achieved by immobilizing antibodies upright oriented on the QCM gold surface by a simple photochemical technique (Photonic Immobilization Technique, PIT based on the UV irradiation of the antibodies, whereas a simple protocol provided by the manufacturer is applied to functionalize the gold nanoparticles. Thus, in a non-competitive approach, the small analyte is made detectable by weighing it down through a "sandwich protocol" with a second antibody tethered to heavy gold nanoparticles. The immunosensor has been proved to be effective against the parathion while showing no cross reaction when a mixture of compounds very similar to parathion is analyzed.The immunosensor described in this paper can be easily applied to any small molecule for which polyclonal antibodies are available since both the functionalization procedure of the QCM probe surface and gold nanoparticle can be applied to any IgG, thereby making our device of general application in terms of target analyte.

  7. The use of quartz crystal microbalance with dissipation (QCM-D for studying nanoparticle-induced platelet aggregation

    Directory of Open Access Journals (Sweden)

    Santos-Martinez MJ

    2012-01-01

    Full Text Available Maria Jose Santos-Martinez1–3, Iwona Inkielewicz-Stepniak1,4, Carlos Medina1, Kamil Rahme5,6, Deirdre M D'Arcy1, Daniel Fox3, Justin D Holmes3,5, Hongzhou Zhang3, Marek Witold Radomski3,51School of Pharmacy and Pharmaceutical Sciences, 2School of Medicine, 3Center for Research on Adaptive Nanostructures and Nanodevices, Trinity College Dublin, Dublin, Ireland; 4Department of Medicinal Chemistry, Medical University of Gdansk, Gdansk, Poland; 5Materials and Supercritical Fluids Group, Department of Chemistry and the Tyndall National Institute, University College Cork, Cork, Ireland; 6Department of Sciences, Faculty of Natural and Applied Science, Notre Dame University, Zouk Mosbeh, LebanonAbstract: Interactions between blood platelets and nanoparticles have both pharmacological and toxicological significance and may lead to platelet activation and aggregation. Platelet aggregation is usually studied using light aggregometer that neither mimics the conditions found in human microvasculature nor detects microaggregates. A new method for the measurement of platelet microaggregation under flow conditions using a commercially available quartz crystal microbalance with dissipation (QCM-D has recently been developed. The aim of the current study was to investigate if QCM-D could be used for the measurement of nanoparticle-platelet interactions. Silica, polystyrene, and gold nanoparticles were tested. The interactions were also studied using light aggregometry and flow cytometry, which measured surface abundance of platelet receptors. Platelet activation was imaged using phase contrast and scanning helium ion microscopy. QCM-D was able to measure nanoparticle-induced platelet microaggregation for all nanoparticles tested at concentrations that were undetectable by light aggregometry and flow cytometry. Microaggregates were measured by changes in frequency and dissipation, and the presence of platelets on the sensor surface was confirmed and imaged by

  8. Measurement of the Ru surface content of electrodeposited PtRu electrodes with the electrochemical quartz crystal microbalance: implications for methanol and CO electrooxidation

    NARCIS (Netherlands)

    Frelink, T.; Visscher, W.; Veen, van J.A.R.

    1996-01-01

    To obtain the surface content of Ru in rough electrocodeposited PtRu electrodes, the mass change of a Pt electrode during Ru deposition was measured with the electrochemical quartz crystal microbalance (EQCMB). It is shown that there is a correlation between the potential of the surface oxide

  9. Small quartz silica spheres induced disorder in octylcyanobiphenyl (8CB) liquid crystals: A thermal study

    International Nuclear Information System (INIS)

    Marinelli, M.; Ghosh, A. K.; Mercuri, F.

    2001-01-01

    A photopyroelectric technique has been applied to the study of specific heat and thermal conductivity of homeotropically aligned mixtures of small quartz spheres (aerosil) and octylcyanobiphenyl (8CB) with concentration 0≤ρ s ≤0.04g/cm 3 . Thermal conductivity data show that, even at these very low concentrations, an annealing of the disorder introduced by the aerosil takes place on cooling at the smectic-A - nematic (Sm-A - N) phase transition and not only at the nematic-isotropic (N-I) one. This means that there is some elastic strain in the nematic phase of the sample which is not quenched. Accordingly the suppression of the N-I transition temperature as a function of ρ s does not fit a random field with a random dilution model that accounts for random quenched disorder only. High resolution specific heat measurements at the A-N and N-I transition show the effect of the aerosil is not the same. While in the first case its peak is suppressed with increasing concentration, in the second case there are some indications that outside the two-phase coexistence region it is enhanced. The effect of surface-induced alignment is also discussed to explain some discrepancies between our data and the ones reported in literature. It is concluded that the amount of disorder in the sample does not depend on ρ s only, but also on other variables such as external fields. Finally, a relaxation phenomenon in the aerosil network that partially compensate the disordering effect of the particles is suggested to explain the concentration dependence of the transition temperatures

  10. Note: A quartz cell with Pt single crystal bead electrode for electrochemical scanning tunneling microscope measurements.

    Science.gov (United States)

    Xia, Zhigang; Wang, Jihao; Hou, Yubin; Lu, Qingyou

    2014-09-01

    In this paper, we provide and demonstrate a design of a unique cell with Pt single crystal bead electrode for electrochemical scanning tunneling microscope (ECSTM) measurements. The active metal Pt electrode can be protected from air contamination during the preparation process. The transparency of the cell allows the tip and bead to be aligned by direct observation. Based on this, a new and effective alignment method is introduced. The high-quality bead preparations through this new cell have been confirmed by the ECSTM images of Pt (111).

  11. Superior environment resistance of quartz crystal microbalance with anatase TiO2/ZnO nanorod composite films

    International Nuclear Information System (INIS)

    Qiang, Wei; Wei, Li; Shaodan, Wang; Yu, Bai

    2015-01-01

    Graphical abstract: ZnO nanorod array being prepared by an in situ method on the QCM coated with Au film via hydrothermal process and surface modification with coated TiO 2 by sol–gel methods to form a superhydrophobic TiO 2 /ZnO composite film the anatase TiO 2 /ZnO nanorod composite film with a sharp, pencil-like structure exhibiting excellent superhydrophobicity (water contact angle of 155°), non-sticking water properties, and an autonomous cleaning property under UV irradiation. The anatase TiO 2 /ZnO nanorod composite film facilitates the precise measurement and extended lifetime of the QCM for the detection of organic gas molecules. - Highlights: • This work combines, for the first time, the advantage of the TiO 2 /ZnO composite film on photocatalysis and reversible super-hydrophobic and super-hydrophilic transition, and puts forward a solution to satisfy weatherability of quartz crystal microbalance in long-term application. • The anatase TiO 2 /ZnO nanorod composite film with pencil structure exhibit excellent super-hydrophobicity (water contact angle can reach 155°), no-sticking water properties and self-cleaning property under UV irradiation. • The photocatalysis and reversible super-hydrophobic and super-hydrophilic transition of the TiO 2 /ZnO nanorod composite film is stable in long-term application. - Abstract: The precise measurement of quartz crystal microbalance (QCM) in the detection and weighing of organic gas molecules is achieved due to excellent superhydrophobicity of a deposited film composite. Photocatalysis is utilized as a method for the self-cleaning of organic molecules on the QCM for extended long-term stability in the precision of the instrument. In this paper, ZnO nanorod array is prepared via in situ methods on the QCM coated with Au film via hydrothermal process. Subsequently, a TiO 2 /ZnO composite film is synthesized by surface modification with TiO 2 via sol–gel methods. Results show the anatase TiO 2 /ZnO nanorod

  12. Monitoring of morphology and physical properties of cultured cells using a micro camera and a quartz crystal with transparent indium tin oxide electrodes after injections of glutaraldehyde and trypsin

    International Nuclear Information System (INIS)

    Kang, Hyen-Wook; Ida, Kazumi; Yamamoto, Yuji; Muramatsu, Hiroshi

    2008-01-01

    For investigating the effects of chemical stimulation to cultured cells, we have developed a quartz crystal sensor system with a micro charge-coupled device (CCD) camera that enables microphotograph imaging simultaneously with quartz crystal measurement. Human hepatoma cell line (HepG2) cells were cultured on the quartz crystal through a collagen film. The electrode of the quartz crystal was made of indium tin oxide (ITO) transparent electrodes that enable to obtain a transparent mode photograph. Glutaraldehyde and trypsin were injected to the chamber of the cells, respectively. The response of the quartz crystal was monitored and microphotographs were recorded, and the resonance frequency and resonance resistance were analyzed with an F-R diagram that plotted the resonance frequency and resonance resistance. In the case of the glutaraldehyde injection, the cells responded in two steps that included the fast response of the cross-linking reaction and the successive internal change in the cells. In the case of the trypsin injection, the responses included two processes. In the first step, cell adhesion factors were cleaved and the cell structure became round, and in the next step, the cells were deposited on the quartz crystal surface and the surface of the cells was directly in contact with the quartz crystal surface

  13. Radiation defect production in quartz crystals with various structure perfectness degree; Radiatsionnoe defektoobrazovanie v kristallakh kvartsa s razlichnoj stepen`yu sovershenstva struktury

    Energy Technology Data Exchange (ETDEWEB)

    Khushvakov, O B

    1992-01-01

    Radiation defects production processes in pure and doped quartz crystals with various structure defectness, caused by preliminary irradiation with neutrons, protons, deuterons and {alpha}-particles, during various electron excitation densities were investigated. The distribution of colour centres along the thickness of irradiated quartz crystals was measured. It was supposed that colour centres are produced on account of inelastic energy losses as the result of collective decay of two or more interacting excitons. It was shown that in quartz crystals under the actions of protons with overthreshold energy 18 MeV and electrons with subthreshold energy 100 keV the same structure defects are formed. It was established that radiation defect production process has two stages. The first stage reveals radiation defects produced by preliminary irradiation. The second one reveals additional intrinsic defects formed under the action of gamma-rays and electrons. The probability dependence of defect production on neutron fluence and masses of incident particles was studied. It was supposed that the creation of additional defects in preliminary irradiated crystals is due to non-radiative decay of electron excitations near radiation-induced defects. It was shown that increase of impurity concentration leads to rate growth of accumulation of radiation induced defects. (A.A.D.) 15 refs. 4 figs.

  14. Polyacrylonitrile nanofiber as polar solvent N,N-dimethyl formamide sensor based on quartz crystal microbalance technique

    Science.gov (United States)

    Rianjanu, A.; Julian, T.; Hidayat, S. N.; Suyono, E. A.; Kusumaatmaja, A.; Triyana, K.

    2018-04-01

    Here, we describe an N,N-dimethyl formamide (DMF) vapour sensor fabricated by coating polyacrylonitrile (PAN) nanofiber structured on quartz crystal microbalance (QCM). The PAN nanofiber sensors with an average diameter of 225 nm to 310 nm were fabricated via electrospinning process with different mass deposition on QCM substrate. The nanostructured of PAN nanofiber offers a high specific surface area that improved the sensing performance of nanofiber sensors. Benefiting from that fine structure, and high polymer-solvent affinity between PAN and DMF, the development of DMF sensors presented good response at ambient temperature. Since there is no chemical reaction between PAN nanofiber and DMF vapour, weak physical interaction such absorption and swelling were responsible for the sensing behavior. The results are indicating that the response of PAN nanofiber sensors has more dependency on the nanofiber structure (specific surface area) rather than its mass deposition. The sensor also showed good stability after a few days sensing. These findings have significant implications for developing DMF vapour sensor based on QCM coated polymer nanofibers.

  15. In situ NMR and electrochemical quartz crystal microbalance techniques reveal the structure of the electrical double layer in supercapacitors

    Science.gov (United States)

    Griffin, John M.; Forse, Alexander C.; Tsai, Wan-Yu; Taberna, Pierre-Louis; Simon, Patrice; Grey, Clare P.

    2015-08-01

    Supercapacitors store charge through the electrosorption of ions on microporous electrodes. Despite major efforts to understand this phenomenon, a molecular-level picture of the electrical double layer in working devices is still lacking as few techniques can selectively observe the ionic species at the electrode/electrolyte interface. Here, we use in situ NMR to directly quantify the populations of anionic and cationic species within a working microporous carbon supercapacitor electrode. Our results show that charge storage mechanisms are different for positively and negatively polarized electrodes for the electrolyte tetraethylphosphonium tetrafluoroborate in acetonitrile; for positive polarization charging proceeds by exchange of the cations for anions, whereas for negative polarization, cation adsorption dominates. In situ electrochemical quartz crystal microbalance measurements support the NMR results and indicate that adsorbed ions are only partially solvated. These results provide new molecular-level insight, with the methodology offering exciting possibilities for the study of pore/ion size, desolvation and other effects on charge storage in supercapacitors.

  16. Development of a Quartz Crystal Microbalance Sensor Modified by Nano-Structured Polyaniline for Detecting the Plasticizer in Gaseous State

    Directory of Open Access Journals (Sweden)

    Hui XU

    2014-01-01

    Full Text Available A quartz crystal microbalance (QCM modified by a film of nano-structured polyaniline (nano-PANI is developed as a gas sensor for detecting the presence of the plasticizer, such as dibutyl phthalate (DBP in the ambient. Nano-PANI is prepared using a non-template method and the films are deposited using physical coating method. Scanning electron microscopy is used to characterize the nano-PANI film. The sensor response towards DBP is tested in a sealed gas chamber. The QCM resonant frequency shift is measured due to the absorption of DBP with different concentration ranging from 0.04 to 1.2 ppm. The experiment results show that the variation of the frequency is a linear function of DBP concentration and the sensitivity up to 54 Hz/ppm could be achieved by using the researched nano-PANI on QCM. To investigate the selectivity, the potential interfering analytes such as acetone, ethanol, acetaldehyde and formaldehyde are tested. And the mechanism hypothesis of the nano-PANI sensitive to the plasticizer is analyzed.

  17. Determination of functionalized gold nanoparticles incorporated in hydrophilic and hydrophobic microenvironments by surface modification of quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Tsui-Hsun [Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC (China); Institute of Medical Mechatronics, Chang Gung University, Tao-Yuan, Taiwan, ROC (China); Liao, Shu-Chuan [Center of Thin Film Technologies and Applications, Mingchi University of Technology, Taipei, Taiwan, ROC (China); Chen, Ying-Fang [Department of Dentistry, Yun-Lin Branch, National Taiwan University Hospital, Dou-Liu, Yun-Lin, Taiwan, ROC (China); Huang, Yi-You [Institute of Biomedical Engineering, College of Engineering, College of Medicine, National Taiwan University, Taipei, Taiwan, ROC (China); Wei, Yi-Syuan [Department of Materials Engineering, Tatung University, 40 Zhongshan North Road, 3rd Section, Taipei 104, Taiwan, ROC (China); Tu, Shu-Ju, E-mail: sjt@cgu.edu.tw [Department of Medical Imaging and Radiological Sciences, Chang Gung University, 259 Wen-Hwa, 1st Road, Kwei-Shan, Tao-Yuan 133, Taiwan, ROC (China); Chen, Ko-Shao, E-mail: kschen@ttu.edu.tw [Department of Materials Engineering, Tatung University, 40 Zhongshan North Road, 3rd Section, Taipei 104, Taiwan, ROC (China)

    2013-06-01

    In this study, plasma deposition methods were used to immobilize Au electrode of a quartz crystal microbalance (QCM) to create different microenvironments for mass measurement of various modified Au nanoparticles (AuNPs). AuNPs were modified by 11-mercaptoundecanoic acid (MUA) and 1-decanethiol (DCT) for potential applications to drug release, protective coatings, and immunosensors. We aimed to develop a highly sensitive and reliable method to quantify the mass of various modified AuNPs. The surface of AuNPs and Au electrode was coated with polymer films, as determined by Fourier transform infrared spectroscopy and atomic force microscopy. Measurements obtained for various AuNPs and the plasma-treated surface of the Au electrode were compared with those obtained for an untreated Au electrode. According to the resonant frequency shift of QCM, a linear relationship was observed that significantly differed for AuNPs, MUA-AuNPs, and DCT-AuNPs (R{sup 2} range, 0.94–0.965, 0.934–0.972, and 0.874–0.9514, respectively). Compared to inductively coupled plasma and micro-computerized tomography, the QCM method with plasma treatment has advantages of real-time monitoring, greater sensitivity, and lower cost. Our results demonstrate that surface modifications measured by a QCM system for various modified AuNPs were reliable.

  18. Determination of functionalized gold nanoparticles incorporated in hydrophilic and hydrophobic microenvironments by surface modification of quartz crystal microbalance

    International Nuclear Information System (INIS)

    Wu, Tsui-Hsun; Liao, Shu-Chuan; Chen, Ying-Fang; Huang, Yi-You; Wei, Yi-Syuan; Tu, Shu-Ju; Chen, Ko-Shao

    2013-01-01

    In this study, plasma deposition methods were used to immobilize Au electrode of a quartz crystal microbalance (QCM) to create different microenvironments for mass measurement of various modified Au nanoparticles (AuNPs). AuNPs were modified by 11-mercaptoundecanoic acid (MUA) and 1-decanethiol (DCT) for potential applications to drug release, protective coatings, and immunosensors. We aimed to develop a highly sensitive and reliable method to quantify the mass of various modified AuNPs. The surface of AuNPs and Au electrode was coated with polymer films, as determined by Fourier transform infrared spectroscopy and atomic force microscopy. Measurements obtained for various AuNPs and the plasma-treated surface of the Au electrode were compared with those obtained for an untreated Au electrode. According to the resonant frequency shift of QCM, a linear relationship was observed that significantly differed for AuNPs, MUA-AuNPs, and DCT-AuNPs (R 2 range, 0.94–0.965, 0.934–0.972, and 0.874–0.9514, respectively). Compared to inductively coupled plasma and micro-computerized tomography, the QCM method with plasma treatment has advantages of real-time monitoring, greater sensitivity, and lower cost. Our results demonstrate that surface modifications measured by a QCM system for various modified AuNPs were reliable.

  19. Preparation of a molecularly imprinted sensor based on quartz crystal microbalance for specific recognition of sialic acid in human urine.

    Science.gov (United States)

    Qiu, Xiuzhen; Xu, Xian-Yan; Chen, Xuncai; Wu, Yiyong; Guo, Huishi

    2018-05-08

    A novel molecularly imprinted quartz crystal microbalance (QCM) sensor was successfully prepared for selective determination of sialic acid (SA) in human urine samples. To obtain the QCM sensor, we first modified the gold surface of the QCM chip by self-assembling of allylmercaptane to introduce polymerizable double bonds on the chip surface. Then, SA molecularly imprinted polymer (MIP) nanofilm was attached to the modified QCM chip surface. For comparison, we have also characterized the nonmodified and improved surfaces of the QCM sensor by using atomic force microscopy (AFM) and Fourier transform infrared (FTIR) spectroscopy. We then tested the selectivity and detection limit of the imprinted QCM sensor via a series of adsorption experiments. The results show a linear response in the range of 0.025-0.50 μmol L -1 for sialic acid. Moreover, the limit of detection (LOD) of the prepared imprinted QCM sensor was found to be 1.0 nmol L -1 for sialic acid, and high recovery values range from 87.6 to 108.5% with RSD sensor was developed and used to detect sialic acid in human urine samples. Graphical abstract Specific recognition of sialic acid by the MIP-QCM sensor system.

  20. Real-time monitoring of peptic and tryptic digestions of bovine β-casein using quartz crystal microbalance

    International Nuclear Information System (INIS)

    Huenerbein, Andreas; Schmelzer, Christian E.H.; Neubert, Reinhard H.H.

    2007-01-01

    In this study peptic and tryptic digestions of bovine β-casein were investigated using quartz crystal microbalance (QCM). β-Casein, which was used as a model protein, was immobilized on the surface of the QCM sensor where its degradation caused shifts in the resonant frequency. Atomic force microscopy was applied for the characterization of the protein layer. Different pH-values for peptic or tryptic digestions were chosen to visualize their effect on enzyme activity. Lower frequency shifts were observed at pH-values deviating from those at the maximum enzyme activity. In the case of the peptic digestion the frequency shift at pH 4 was more than 10 times smaller than those at pH 2. The frequency shifts for tryptic digestions at pH 5.4 and pH 6.4 were about two thirds compared to that obtained for the digestion at pH 7.4. The identification of peptides using MALDI-ToF mass spectrometry was used for verification of the proteolyses of the immobilized protein. Furthermore, it was shown that the QCM technique allows close observation of the effect of different pH-values on the immobilized casein layer. All in all, QCM facilitates the monitoring of the progress of enzymatic reactions in real-time

  1. Real-time monitoring of peptic and tryptic digestions of bovine {beta}-casein using quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Huenerbein, Andreas [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany)]. E-mail: andreas.huenerbein@pharmazie.uni-halle.de; Schmelzer, Christian E.H. [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany); Neubert, Reinhard H.H. [Institute of Pharmaceutics and Biopharmaceutics, Martin Luther University Halle-Wittenberg, Wolfgang-Langenbeck-Str. 4, 06120 Halle (Saale) (Germany)

    2007-02-12

    In this study peptic and tryptic digestions of bovine {beta}-casein were investigated using quartz crystal microbalance (QCM). {beta}-Casein, which was used as a model protein, was immobilized on the surface of the QCM sensor where its degradation caused shifts in the resonant frequency. Atomic force microscopy was applied for the characterization of the protein layer. Different pH-values for peptic or tryptic digestions were chosen to visualize their effect on enzyme activity. Lower frequency shifts were observed at pH-values deviating from those at the maximum enzyme activity. In the case of the peptic digestion the frequency shift at pH 4 was more than 10 times smaller than those at pH 2. The frequency shifts for tryptic digestions at pH 5.4 and pH 6.4 were about two thirds compared to that obtained for the digestion at pH 7.4. The identification of peptides using MALDI-ToF mass spectrometry was used for verification of the proteolyses of the immobilized protein. Furthermore, it was shown that the QCM technique allows close observation of the effect of different pH-values on the immobilized casein layer. All in all, QCM facilitates the monitoring of the progress of enzymatic reactions in real-time.

  2. In situ measurement of the mass concentration of flame-synthesized nanoparticles using quartz-crystal microbalance

    International Nuclear Information System (INIS)

    Hevroni, A; Golan, H; Fialkov, A; Tsionsky, V; Markovich, G; Cheskis, S; Rahinov, I

    2011-01-01

    A novel in situ method for measurement of mass concentration of nanoparticles (NPs) formed in flames is proposed. In this method, the deposition rate of NPs collected by a molecular beam sampling system is measured by quartz-crystal microbalance (QCM). It is the only existing method which allows direct measurement of NP mass concentration profiles in flames. The feasibility of the method was demonstrated by studying iron oxide NP formation in low-pressure methane/oxygen/nitrogen flames doped with iron pentacarbonyl. The system was tested under fuel-lean and fuel-rich flame conditions. Good agreement between measured QCM deposition rates and their estimations obtained by the transmission electron microscopy analysis of samples collected from the molecular beam has been demonstrated. The sensitivity of the method is comparable to that of particle mass spectrometry (PMS). Combination of the QCM technique with PMS and/or optical measurements can provide new qualitative information which is important for elucidation of the mechanisms governing the NP flame synthesis

  3. Adsorption Analysis of Lactoferrin to Titanium, Stainless Steel, Zirconia, and Polymethyl Methacrylate Using the Quartz Crystal Microbalance Method

    Directory of Open Access Journals (Sweden)

    Eiji Yoshida

    2016-01-01

    Full Text Available It is postulated that biofilm formation in the oral cavity causes some oral diseases. Lactoferrin is an antibacterial protein in saliva and an important defense factor against biofilm development. We analyzed the adsorbed amount of lactoferrin and the dissociation constant (Kd of lactoferrin to the surface of different dental materials using an equilibrium analysis technique in a 27 MHz quartz crystal microbalance (QCM measurement. Four different materials, titanium (Ti, stainless steel (SUS, zirconia (ZrO2 and polymethyl methacrylate (PMMA, were evaluated. These materials were coated onto QCM sensors and the surfaces characterized by atomic force microscopic observation, measurements of surface roughness, contact angles of water, and zeta potential. QCM measurements revealed that Ti and SUS showed a greater amount of lactoferrin adsorption than ZrO2 and PMMA. Surface roughness and zeta potential influenced the lactoferrin adsorption. On the contrary, the Kd value analysis indicated that the adsorbed lactoferrin bound less tightly to the Ti and SUS surfaces than to the ZrO2 and PMMA surfaces. The hydrophobic interaction between lactoferrin and ZrO2 and PMMA is presumed to participate in better binding of lactoferrin to ZrO2 and PMMA surfaces. It was revealed that lactoferrin adsorption behavior was influenced by the characteristics of the material surface.

  4. Peptide-membrane interactions of arginine-tryptophan peptides probed using quartz crystal microbalance with dissipation monitoring.

    KAUST Repository

    Rydberg, Hanna A

    2014-04-18

    Membrane-active peptides include peptides that can cross cellular membranes and deliver macromolecular cargo as well as peptides that inhibit bacterial growth. Some of these peptides can act as both transporters and antibacterial agents. It is desirable to combine the knowledge from these two different fields of membrane-active peptides into design of new peptides with tailored actions, as transporters of cargo or as antibacterial substances, targeting specific membranes. We have previously shown that the position of the amino acid tryptophan in the peptide sequence of three arginine-tryptophan peptides affects their uptake and intracellular localization in live mammalian cells, as well as their ability to inhibit bacterial growth. Here, we use quartz crystal microbalance with dissipation monitoring to assess the induced changes caused by binding of the three peptides to supported model membranes composed of POPC, POPC/POPG, POPC/POPG/cholesterol or POPC/lactosyl PE. Our results indicate that the tryptophan position in the peptide sequence affects the way these peptides interact with the different model membranes and that the presence of cholesterol in particular seems to affect the membrane interaction of the peptide with an even distribution of tryptophans in the peptide sequence. These results give mechanistic insight into the function of these peptides and may aid in the design of membrane-active peptides with specified cellular targets and actions.

  5. Peptide-membrane interactions of arginine-tryptophan peptides probed using quartz crystal microbalance with dissipation monitoring.

    KAUST Repository

    Rydberg, Hanna A; Kunze, Angelika; Carlsson, Nils; Altgä rde, Noomi; Svedhem, Sofia; Nordé n, Bengt

    2014-01-01

    Membrane-active peptides include peptides that can cross cellular membranes and deliver macromolecular cargo as well as peptides that inhibit bacterial growth. Some of these peptides can act as both transporters and antibacterial agents. It is desirable to combine the knowledge from these two different fields of membrane-active peptides into design of new peptides with tailored actions, as transporters of cargo or as antibacterial substances, targeting specific membranes. We have previously shown that the position of the amino acid tryptophan in the peptide sequence of three arginine-tryptophan peptides affects their uptake and intracellular localization in live mammalian cells, as well as their ability to inhibit bacterial growth. Here, we use quartz crystal microbalance with dissipation monitoring to assess the induced changes caused by binding of the three peptides to supported model membranes composed of POPC, POPC/POPG, POPC/POPG/cholesterol or POPC/lactosyl PE. Our results indicate that the tryptophan position in the peptide sequence affects the way these peptides interact with the different model membranes and that the presence of cholesterol in particular seems to affect the membrane interaction of the peptide with an even distribution of tryptophans in the peptide sequence. These results give mechanistic insight into the function of these peptides and may aid in the design of membrane-active peptides with specified cellular targets and actions.

  6. Probing adsorption of polyacrylamide-based polymers on anisotropic Basal planes of kaolinite using quartz crystal microbalance.

    Science.gov (United States)

    Alagha, Lana; Wang, Shengqun; Yan, Lujie; Xu, Zhenghe; Masliyah, Jacob

    2013-03-26

    Quartz crystal microbalance with dissipation (QCM-D) was applied to investigate the adsorption characteristics of polyacrylamide-based polymers (PAMs) on anisotropic basal planes of kaolinite. Kaolinite basal planes were differentiated by depositing kaolinite nanoparticles (KNPs) on silica and alumina sensors in solutions of controlled pH values. Adsorption of an in-house synthesized organic-inorganic Al(OH)3-PAM (Al-PAM) as an example of cationic hybrid PAM and a commercially available partially hydrolyzed polyacrylamide (MF1011) as an example of anionic PAM was studied. Cationic Al-PAM was found to adsorb irreversibly and preferentially on tetrahedral silica basal planes of kaolinite. In contrast, anionic MF1011 adsorbed strongly on aluminum-hydroxy basal planes, while its adsorption on tetrahedral silica basal planes was weak and reversible. Adsorption study revealed that both electrostatic attraction and hydrogen-bonding mechanisms contribute to adsorption of PAMs on kaolinite. The adsorbed Al-PAM layer was able to release trapped water overtime and became more compact, while MF1011 film became more dissipative as backbones stretched out from kaolinite surface with minimal overlapping. Experimental results obtained from this study provide clear insights into the phenomenon that governs flocculation-based solid-liquid separation processes using multicomponent flocculants of anionic and cationic nature.

  7. The use of quartz crystal microbalance with dissipation (QCM-D) for studying nanoparticle-induced platelet aggregation

    Science.gov (United States)

    Santos-Martinez, Maria Jose; Inkielewicz-Stepniak, Iwona; Medina, Carlos; Rahme, Kamil; D’Arcy, Deirdre M; Fox, Daniel; Holmes, Justin D; Zhang, Hongzhou; Radomski, Marek Witold

    2012-01-01

    Interactions between blood platelets and nanoparticles have both pharmacological and toxicological significance and may lead to platelet activation and aggregation. Platelet aggregation is usually studied using light aggregometer that neither mimics the conditions found in human microvasculature nor detects microaggregates. A new method for the measurement of platelet microaggregation under flow conditions using a commercially available quartz crystal microbalance with dissipation (QCM-D) has recently been developed. The aim of the current study was to investigate if QCM-D could be used for the measurement of nanoparticle-platelet interactions. Silica, polystyrene, and gold nanoparticles were tested. The interactions were also studied using light aggregometry and flow cytometry, which measured surface abundance of platelet receptors. Platelet activation was imaged using phase contrast and scanning helium ion microscopy. QCM-D was able to measure nanoparticle-induced platelet microaggregation for all nanoparticles tested at concentrations that were undetectable by light aggregometry and flow cytometry. Microaggregates were measured by changes in frequency and dissipation, and the presence of platelets on the sensor surface was confirmed and imaged by phase contrast and scanning helium ion microscopy. PMID:22275839

  8. Determination of functionalized gold nanoparticles incorporated in hydrophilic and hydrophobic microenvironments by surface modification of quartz crystal microbalance

    Science.gov (United States)

    Wu, Tsui-Hsun; Liao, Shu-Chuan; Chen, Ying-Fang; Huang, Yi-You; Wei, Yi-Syuan; Tu, Shu-Ju; Chen, Ko-Shao

    2013-06-01

    In this study, plasma deposition methods were used to immobilize Au electrode of a quartz crystal microbalance (QCM) to create different microenvironments for mass measurement of various modified Au nanoparticles (AuNPs). AuNPs were modified by 11-mercaptoundecanoic acid (MUA) and 1-decanethiol (DCT) for potential applications to drug release, protective coatings, and immunosensors. We aimed to develop a highly sensitive and reliable method to quantify the mass of various modified AuNPs. The surface of AuNPs and Au electrode was coated with polymer films, as determined by Fourier transform infrared spectroscopy and atomic force microscopy. Measurements obtained for various AuNPs and the plasma-treated surface of the Au electrode were compared with those obtained for an untreated Au electrode. According to the resonant frequency shift of QCM, a linear relationship was observed that significantly differed for AuNPs, MUA-AuNPs, and DCT-AuNPs (R2 range, 0.94-0.965, 0.934-0.972, and 0.874-0.9514, respectively). Compared to inductively coupled plasma and micro-computerized tomography, the QCM method with plasma treatment has advantages of real-time monitoring, greater sensitivity, and lower cost. Our results demonstrate that surface modifications measured by a QCM system for various modified AuNPs were reliable.

  9. Simultaneous detection of surface coverage and structure of krypton films on gold by helium atom diffraction and quartz crystal microbalance techniques.

    Science.gov (United States)

    Danışman, M Fatih; Özkan, Berrin

    2011-11-01

    We describe a quartz crystal microbalance setup that can be operated at low temperatures in ultra high vacuum with gold electrode surfaces acting as substrate surface for helium diffraction measurements. By simultaneous measurement of helium specular reflection intensity from the electrode surface and resonance frequency shift of the crystal during film adsorption, helium diffraction data can be correlated to film thickness. In addition, effects of interfacial viscosity on the helium diffraction pattern could be observed. To this end, first, flat gold films on AT cut quartz crystals were prepared which yield high enough helium specular reflection intensity. Then the crystals were mounted in the helium diffractometer sample holder and driven by means of a frequency modulation driving setup. Different crystal geometries were tested to obtain the best quality factor and preliminary measurements were performed on Kr films on gold surfaces. While the crystal structure and coverage of krypton films as a function of substrate temperature could successfully be determined, no depinning effects could be observed. © 2011 American Institute of Physics

  10. Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance.

    Science.gov (United States)

    Sharma, Shailesh; Gahan, David; Scullin, Paul; Doyle, James; Lennon, Jj; Vijayaraghavan, Rajani K; Daniels, Stephen; Hopkins, M B

    2016-04-01

    A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

  11. Measurement of deposition rate and ion energy distribution in a pulsed dc magnetron sputtering system using a retarding field analyzer with embedded quartz crystal microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Shailesh, E-mail: shailesh.sharma6@mail.dcu.ie [Dublin City University, Glasnevin, Dublin 9 (Ireland); Impedans Limited, Chase House, City Junction Business Park, Northern Cross, D17 AK63, Dublin 17 (Ireland); Gahan, David, E-mail: david.gahan@impedans.com; Scullin, Paul; Doyle, James; Lennon, Jj; Hopkins, M. B. [Impedans Limited, Chase House, City Junction Business Park, Northern Cross, D17 AK63, Dublin 17 (Ireland); Vijayaraghavan, Rajani K.; Daniels, Stephen [Dublin City University, Glasnevin, Dublin 9 (Ireland)

    2016-04-15

    A compact retarding field analyzer with embedded quartz crystal microbalance has been developed to measure deposition rate, ionized flux fraction, and ion energy distribution arriving at the substrate location. The sensor can be placed on grounded, electrically floating, or radio frequency (rf) biased electrodes. A calibration method is presented to compensate for temperature effects in the quartz crystal. The metal deposition rate, metal ionization fraction, and energy distribution of the ions arriving at the substrate location are investigated in an asymmetric bipolar pulsed dc magnetron sputtering reactor under grounded, floating, and rf biased conditions. The diagnostic presented in this research work does not suffer from complications caused by water cooling arrangements to maintain constant temperature and is an attractive technique for characterizing a thin film deposition system.

  12. Investigation of the interaction between liquid and micro/nanostructured surfaces during condensation with quartz crystal microbalance

    Science.gov (United States)

    Su, Junwei

    Dropwise condensation (DWC) on hydrophobic surfaces is attracting attention for its great potential in many industrial applications, such as steam power plants, water desalination, and de-icing of aerodynamic surfaces, to list a few. The direct dynamic characterization of liquid/solid interaction can significantly accelerate the progress toward a full understanding of the thermal and mass transport mechanisms during DWC processes. The research focuses on the development of a novel acoustic-based technique for analyzing the liquid/solid interactions of different condensations on micro- and nanostructured surfaces including DWC. hi addition. the newly developed technology was demonstrated for quantitatively sensing different wetting states of liquid on rough surfaces. First, different micro/nanostructures were fabricated on the quartz crystal microbalance (QCM), which serves as acoustic sensor. Polymethyl methacrylate (PMMA) micropillars, with varying heights from 6.03 to 25.02 microm, were fabricated on a quartz crystal microbalance (QCM) substrate by thermal nanoimprinting lithography to form pillar-based QCM (QCM-P). For nanostructured QCM. a copper layer was deposited on the QCM surface and then nanostructures of copper oxide (CuO) films were formed via chemical oxidation in an alkaline solution. Then, these surfaces were treated to make them superhydrophilic or superhydrophobic using oxygen plasma treatment or with coating of 1H,1 H,2H,2H-perfluorooctyl-trichlorosilane (PFOTS). Based on the geometry of these micro/nanostructures, the relationship between the frequency responses of QCM and the wetting states of these surfaces was theoretically investigated. Different theoretical models were established to describing the frequency shift of the micro- and nanostructured QCM in different wetting states. For the microstructured surface, the cantilever based model and a two-degree-of-freedom dynamic model were applied to predict the frequency shift of the QCM-P in

  13. Assessing the adsorption selectivity of linker functionalized, moisture-stable metal-organic framework thin films by means of an environment-controlled quartz crystal microbalance.

    Science.gov (United States)

    Bétard, Angélique; Wannapaiboon, Suttipong; Fischer, Roland A

    2012-11-04

    The stepwise thin film deposition of the robust, hydrophobic [Zn(4)O(dmcapz)(3)](n) (dmcapz = 3,5-dimethyl-4-carboxy-pyrazolato) is reported. The adsorption of small organic probe molecules, including alkanols, toluene, aniline and xylenes, was monitored by an environment-controlled quartz crystal microbalance setup. The adsorption selectivity was tuned by introducing alkyl side chains in the dmcapz linker.

  14. In-situ quartz crystal microgravimetric studies of molecular adsorbates containing thiol and hydroquinone moieties bound to Au(111) surfaces in aqueous electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Mo, Y.; Sukenik, C.; Sandifer, M. [Case Western Univ., Cleveland, OH (United States); Barriga, R.J.; Soriaga, M.P.; Scherson, D. [Texas A& M Univ., College Station, TX (United States)

    1995-12-01

    The microgravimetric properties of monolayers of 2, 5-dihydroxythiophenol, 2,5-dihydroxybenzyl mercaptan, and 2, 5-dihydroxy-4-methylbenzyl mercaptan adsorbed on Au(111) single crystal electrodes were examined by in situ quartz crystal microbalance techniques in aqueous perchloric acid electrolytes. The results obtained are consistent with the reversible loss of an average of about three waters per adsorbed molecule as the layers are oxidized and subsequently reduced. These observations provide evidence for discrete changes in the extent of bound water within the hydroquinone/quinone layer as the oxidation state of the monolayer is changed. 9 refs., 4 figs.

  15. Waveform-preserved unidirectional acoustic transmission based on impedance-matched acoustic metasurface and phononic crystal

    Science.gov (United States)

    Song, Ai-Ling; Chen, Tian-Ning; Wang, Xiao-Peng; Wan, Le-Le

    2016-08-01

    The waveform distortion happens in most of the unidirectional acoustic transmission (UAT) devices proposed before. In this paper, a novel type of waveform-preserved UAT device composed of an impedance-matched acoustic metasurface (AMS) and a phononic crystal (PC) structure is proposed and numerically investigated. The acoustic pressure field distributions and transmittance are calculated by using the finite element method. The subwavelength AMS that can modulate the wavefront of the transmitted wave at will is designed and the band structure of the PC structure is calculated and analyzed. The sound pressure field distributions demonstrate that the unidirectional acoustic transmission can be realized by the proposed UAT device without changing the waveforms of the output waves, which is the distinctive feature compared with the previous UAT devices. The physical mechanism of the unidirectional acoustic transmission is discussed by analyzing the refraction angle changes and partial band gap map. The calculated transmission spectra show that the UAT device is valid within a relatively broad frequency range. The simulation results agree well with the theoretical predictions. The proposed UAT device provides a good reference for designing waveform-preserved UAT devices and has potential applications in many fields, such as medical ultrasound, acoustic rectifiers, and noise insulation.

  16. Characterisation of a natural quartz crystal as a reference material for microanalytical determination of Ti, Al, Li, Fe, Mn, Ga and Ge

    Science.gov (United States)

    Audetat, Andreas; Garbe-Schonberg, Dieter; Kronz, Andreas; Pettke, Thomas; Rusk, Brian G.; Donovan, John J.; Lowers, Heather

    2015-01-01

    A natural smoky quartz crystal from Shandong province, China, was characterised by laser ablation ICP-MS, electron probe microanalysis (EPMA) and solution ICP-MS to determine the concentration of twenty-four trace and ultra trace elements. Our main focus was on Ti quantification because of the increased use of this element for titanium-in-quartz (TitaniQ) thermobarometry. Pieces of a uniform growth zone of 9 mm thickness within the quartz crystal were analysed in four different LA-ICP-MS laboratories, three EPMA laboratories and one solution-ICP-MS laboratory. The results reveal reproducible concentrations of Ti (57 ± 4 μg g-1), Al (154 ± 15 μg g-1), Li (30 ± 2 μg g-1), Fe (2.2 ± 0.3 μg g-1), Mn (0.34 ± 0.04 μg g-1), Ge (1.7 ± 0.2 μg g-1) and Ga (0.020 ± 0.002 μg g-1) and detectable, but less reproducible, concentrations of Be, B, Na, Cu, Zr, Sn and Pb. Concentrations of K, Ca, Sr, Mo, Ag, Sb, Ba and Au were below the limits of detection of all three techniques. The uncertainties on the average concentration determinations by multiple techniques and laboratories for Ti, Al, Li, Fe, Mn, Ga and Ge are low; hence, this quartz can serve as a reference material or a secondary reference material for microanalytical applications involving the quantification of trace elements in quartz.

  17. Colorado quartz: occurrence and discovery

    Science.gov (United States)

    Kile, D.E.; Modreski, P.J.; Kile, D.L.

    1991-01-01

    The many varieties and associations of quartz found throughout the state rank it as one of the premier worldwide localities for that species. This paper briefly outlines the historical importance of the mineral, the mining history and the geological setting before discussing the varieties of quartz present, its crystallography and the geological enviroments in which it is found. The latter include volcanic rocks and near surface igneous rocks; pegmatites; metamorphic and plutonic rocks; hydrothermal veins; skarns and sedimentary deposits. Details of the localities and mode of occurrence of smoky quartz, amethyst, milky quartz, rock crystal, rose quartz, citrine, agate and jasper are then given. -S.J.Stone

  18. Separate measurement of the density and viscosity of a liquid using a quartz crystal microbalance based on admittance analysis (QCM-A)

    International Nuclear Information System (INIS)

    Itoh, Atsushi; Ichihashi, Motoko

    2011-01-01

    We previously used a quartz crystal microbalance (QCM) to identify a frequency f 2 that allows measurement of the mass load without being affected by the viscous load of a liquid in the liquid phase. Here, we determined that frequency in order to separately measure the density and viscosity of a Newtonian liquid. Martin et al separately measured the density and viscosity of a liquid by immersing two quartz resonators, i.e. a smooth-surface resonator and a textured-surface resonator, in the liquid. We used a QCM based on admittance analysis (QCM-A) in the current study to separately measure the viscosity and density of a liquid using only a textured-surface resonator. In the current experiments, we measured the density and viscosity of 500 µl of 10%, 30%, and 50% aqueous glycerol solutions and compared the measured values to reference values. The density obtained had an error of ±1.5% of reference values and the viscosity had an error of about ±5% of reference values. Similar results were obtained with 500 µl of 10%, 30%, and 50% ethanol solutions. Measurement was possible with a quartz resonator, so measurements were made with even smaller samples. The density and viscosity of a liquid were successfully determined with an extremely small amount of liquid, i.e. 10 µl, with almost the same precision as when using 500 µl of the liquid

  19. A comprehensive comparative study of the pre-dose effect for three quartz crystals of different origin

    International Nuclear Information System (INIS)

    Kitis, G.; Pagonis, V.; Chen, R.; Polymeris, G.

    2006-01-01

    The study of the thermoluminescence (TL) sensitivity of quartz due to heat and irradiation treatments is of importance in dating and retrospective dosimetry. A comprehensive comparative study of the pre-dose effect was carried out for three types of quartz of different origin. Complete TL vs. dose and sensitivity S vs. pre-dose curves were obtained for the dose range of 0.1 < D < 400 Gy. Additional complete sensitivity vs. pre-dose curves were obtained for samples which underwent a combined pre-dose irradiation and a subsequent heat treatment to 500 deg. C. Although the TL vs. dose curves showed very different behaviours, the sensitivity vs. pre-dose curves showed several common characteristics. The sensitivity vs. pre-dose curves showed abrupt changes ∼10 Gy. The sensitivity after a combined pre-dose irradiation and heat treatment to 500 deg. C showed a very gradual change in the whole dose range studied. These results are explained qualitatively by using the modified Zimmerman model for quartz. (authors)

  20. The method of impedance transformation for electromagnetic waves propagating in one-dimension plasma photonic crystal

    Energy Technology Data Exchange (ETDEWEB)

    Yao, Jingfeng; Yuan, Chengxun, E-mail: yuancx@hit.edu.cn, E-mail: zhouzx@hit.edu.cn; Gao, Ruilin; Jia, Jieshu; Wang, Ying; Zhou, Zhongxiang, E-mail: yuancx@hit.edu.cn, E-mail: zhouzx@hit.edu.cn; Wang, Xiaoou [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); Wu, Jian [National Key Laboratory of Electromagnetic Environment (LEME), China Research Institute of Radio Wave Propagation, Beijing 102206 (China); Li, Hui [Department of Physics, Harbin Institute of Technology, Harbin 150001 (China); National Key Laboratory of Electromagnetic Environment (LEME), China Research Institute of Radio Wave Propagation, Beijing 102206 (China)

    2016-08-15

    This study focuses on the transmission of normal-incidence electromagnetic waves in one-dimensional plasma photonic crystals. Using the Maxwell's equations in a medium, a method that is based on the concept of impendence is employed to perform the simulation. The accuracy of the method was evaluated by simulating a one-layer plasma and conventional photonic crystal. In frequency-domain, the transmission and reflection coefficients in the unmagnetized plasma photonic crystal were calculated, and the influence factors on plasma photonic crystals including dielectric constants of dielectric, spatial period, filling factor, plasma frequency, and collision frequency were studied.

  1. Disposable micro-fluidic biosensor array for online parallelized cell adhesion kinetics analysis on quartz crystal resonators

    DEFF Research Database (Denmark)

    Cama, G.; Jacobs, T.; Dimaki, Maria

    2010-01-01

    among all the sensors of the array. As well, dedicated sensor interface electronics were developed and optimized for fast spectra acquisition of all 16 QCRs with a miniaturized impedance analyzer. This allowed performing cell cultivation experiments for the observation of fast cellular reaction kinetics...

  2. Interaction analysis of chimeric metal-binding green fluorescent protein and artificial solid-supported lipid membrane by quartz crystal microbalance and atomic force microscopy

    International Nuclear Information System (INIS)

    Prachayasittikul, Virapong; Na Ayudhya, Chartchalerm Isarankura; Hilterhaus, Lutz; Hinz, Andreas; Tantimongcolwat, Tanawut; Galla, Hans-Joachim

    2005-01-01

    Non-specific adsorption and specific interaction between a chimeric green fluorescent protein (GFP) carrying metal-binding region and the immobilized zinc ions on artificial solid-supported lipid membranes was investigated using the quartz crystal microbalance technique and the atomic force microscopy (AFM). Supported lipid bilayer, composed of octanethiol and 1,2-dipalmitoyl-sn-glycero-3-phosphocholine/1,2-dioleoyl-sn-glycero-3-[N- (5-amino-1-carboxypentyl iminodiacetic acid)succinyl] (NTA-DOGS)-Zn 2+ , was formed on the gold electrode of quartz resonator (5 MHz). Binding of the chimeric GFP to zinc ions resulted in a rapid decrease of resonance frequency. Reversibility of the process was demonstrated via the removal of metal ions by EDTA. Nanoscale structural orientation of the chimeric GFP on the membrane was imaged by AFM. Association constant of the specific binding to metal ions was 2- to 3-fold higher than that of the non-specific adsorption, which was caused by the fluidization effect of the metal-chelating lipid molecules as well as the steric hindrance effect. This infers a possibility for a further development of biofunctionalized membrane. However, maximization is needed in order to attain closer advancement to a membrane-based sensor device

  3. 1-Butyl-3-Methylimidazolium Tetrafluoroborate Film as a Highly Selective Sensing Material for Non-Invasive Detection of Acetone Using a Quartz Crystal Microbalance.

    Science.gov (United States)

    Tao, Wenyan; Lin, Peng; Liu, Sili; Xie, Qingji; Ke, Shanming; Zeng, Xierong

    2017-01-20

    Breath acetone serves as a biomarker for diabetes. This article reports 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF₄]), a type of room temperature ionic liquid (RTIL), as a selective sensing material for acetone. The RTIL sensing layer was coated on a quartz crystal microbalance (QCM) for detection. The sensing mechanism is based on a decrease in viscosity and density of the [bmim][BF₄] film due to the solubilization of acetone leading to a positive frequency shift in the QCM. Acetone was detected with a linear range from 7.05 to 750 ppmv. Sensitivity and limit of detection were found to be 3.49 Hz/ppmv and 5.0 ppmv, respectively. The [bmim][BF₄]-modified QCM sensor demonstrated anti-interference ability to commonly found volatile organic compounds in breath, e.g., isoprene, 1,2-pentadiene, d -limonene, and dl -limonene. This technology is useful for applications in non-invasive early diabetic diagnosis.

  4. Immersion angle dependence of the resonant-frequency shift of the quartz crystal microbalance in a liquid: effects of longitudinal wave.

    Science.gov (United States)

    Yoshimoto, Minoru; Kobirata, Satoshi; Aizawa, Hideo; Kurosawa, Shigeru

    2007-06-19

    We investigated the effects of the longitudinal wave on the immersion angle dependence of the resonant-frequency shift, deltaF, of the quartz crystal microbalance, QCM. In order to study exactly the effects, we employed the three types of cells: normal cell, cell with the glass beads and cell with sponge. The longitudinal wave exists in the normal cell. On the other hand, both the cell with the glass beads and the cell with sponge eliminate the longitudinal wave. As results, we have found that the tendencies of deltaF are the same in the three types of cells. That is, we conclude that the longitudinal wave does not have effects on the immersion angle dependence of deltaF.

  5. A survey of the 2001 to 2005 quartz crystal microbalance biosensor literature: applications of acoustic physics to the analysis of biomolecular interactions.

    Science.gov (United States)

    Cooper, Matthew A; Singleton, Victoria T

    2007-01-01

    The widespread exploitation of biosensors in the analysis of molecular recognition has its origins in the mid-1990s following the release of commercial systems based on surface plasmon resonance (SPR). More recently, platforms based on piezoelectric acoustic sensors (principally 'bulk acoustic wave' (BAW), 'thickness shear mode' (TSM) sensors or 'quartz crystal microbalances' (QCM)), have been released that are driving the publication of a large number of papers analysing binding specificities, affinities, kinetics and conformational changes associated with a molecular recognition event. This article highlights salient theoretical and practical aspects of the technologies that underpin acoustic analysis, then reviews exemplary papers in key application areas involving small molecular weight ligands, carbohydrates, proteins, nucleic acids, viruses, bacteria, cells and lipidic and polymeric interfaces. Key differentiators between optical and acoustic sensing modalities are also reviewed. Copyright (c) 2007 John Wiley & Sons, Ltd.

  6. Coherent heat transport in 2D phononic crystals with acoustic impedance mismatch

    International Nuclear Information System (INIS)

    Arantes, A; Anjos, V

    2016-01-01

    In this work we have calculated the cumulative thermal conductivities of micro-phononic crystals formed by different combinations of inclusions and matrices at a sub-Kelvin temperature regime. The low-frequency phonon spectra (up to tens of GHz) were obtained by solving the generalized wave equation for inhomogeneous media with the plane wave expansion method. The thermal conductivity was calculated from Boltzmann transport theory highlighting the role of the low-frequency thermal phonons and neglecting phonon–phonon scattering. A purely coherent thermal transport regime was assumed throughout the structures. Our findings show that the cumulative thermal conductivity drops dramatically when compared with their bulk counterpart. Depending on the structural composition this reduction may be attributed to the phonon group velocity due to a flattening of the phonon dispersion relation, the extinction of phonon modes in the density of states or due to the presence of complete band gaps. According to the contrast between the inclusions and the matrices, three types of two dimensional phononic crystals were considered: carbon/epoxy, carbon/polyethylene and tungsten/silicon, which correspond respectively to a moderate, strong and very strong mismatch in the mechanical properties of these materials. (paper)

  7. In Situ Real-Time Mechanical and Morphological Characterization of Electrodes for Electrochemical Energy Storage and Conversion by Electrochemical Quartz Crystal Microbalance with Dissipation Monitoring.

    Science.gov (United States)

    Shpigel, Netanel; Levi, Mikhael D; Sigalov, Sergey; Daikhin, Leonid; Aurbach, Doron

    2018-01-16

    Quartz crystal microbalance with dissipation monitoring (QCM-D) generates surface-acoustic waves in quartz crystal plates that can effectively probe the structure of films, particulate composite electrodes of complex geometry rigidly attached to quartz crystal surface on one side and contacting a gas or liquid phase on the other side. The output QCM-D characteristics consist of the resonance frequency (MHz frequency range) and resonance bandwidth measured with extra-ordinary precision of a few tenths of Hz. Depending on the electrodes stiffness/softness, QCM-D operates either as a gravimetric or complex mechanical probe of their intrinsic structure. For at least 20 years, QCM-D has been successfully used in biochemical and environmental science and technology for its ability to probe the structure of soft solvated interfaces. Practical battery and supercapacitor electrodes appear frequently as porous solids with their stiffness changing due to interactions with electrolyte solutions or as a result of ion intercalation/adsorption and long-term electrode cycling. Unfortunately, most QCM measurements with electrochemical systems are carried out based on a single (fundamental) frequency and, as such, provided that the resonance bandwidth remains constant, are suitable for only gravimetric sensing. The multiharmonic measurements have been carried out mainly on conducting/redox polymer films rather than on typical composite battery/supercapacitor electrodes. Here, we summarize the most recent publications devoted to the development of electrochemical QCM-D (EQCM-D)-based methodology for systematic characterization of mechanical properties of operating battery/supercapacitor electrodes. By varying the electrodes' composition and structure (thin/thick layers, small/large particles, binders with different mechanical properties, etc.), nature of the electrolyte solutions and charging/cycling conditions, the method is shown to be operated in different application modes. A

  8. Tourmalines from the siderite-quartz-sulphide hydrothermal veins, Gemeric unit, western Carpathians, Slovakia: crystal chemistry and evolution

    Science.gov (United States)

    Bačík, P.; Uher, P.; Dikej, J.; Puškelová, Ľ.

    2018-02-01

    Tourmaline is an important gangue mineral in a large number of Cretaceous siderite-quartz-sulphide hydrothermal veins in the Gemeric Unit, Slovak Ore Mountains, Slovakia, such as Dobšiná, Vlachovo, Rožňavské Bystré, Hnilčík, Rakovnica, Novoveská Huta, Gretla, Rudňany, and Bindt. In this study we combine by electron microprobe analysis, powder X-ray diffraction, Mössbauer and optical emission spectroscopy to determine the range of tourmaline compositions in the deposits and constrain the mechanisms of its precipitation. Selected samples from the mentioned deposits belong mostly to the alkali group, schorl to dravite series, rarely dominant X-site vacant foititic tourmaline (Vlachovo and Bindt) and oxy-dravite compositions (Hnilčík) were detected. Rim zones of some schorlitic tourmalines show high concentrations of Ti (up to 2.35 wt.% TiO2, 0.30 apfu; Rožňavské Bystré). The chemical composition is mostly controlled by alkali-deficient X □AlNa-1(Mg,Fe2+)-1 and proton-deficient AlO(Mg,Fe2+)-1(OH)-1 substitutions. Titanium is incorporated into the structure by Y Ti Y (Mg,Fe) Y Al-2, Y Ti Z Mg Y Al-1 Z Al-1, Y TiO( Y AlOH), and X Ca Y Ti Z MgO2 X □-1 Y,Z Al-2(OH)-2 substitutions. Along trace elements, Sr and V attain concentrations of 80-450 and 70-320 ppm, respectively. The unit-cell parameter a varies between 15.960 and 15.985 Å; variations in c are larger, between 7.177 and 7.236 Å indicating the presence of Fe3+ and Mg2+ at Z site. Mössbauer spectroscopy has shown variable Fe3+ proportions (0.17 -0.55 apfu) in all samples. The gathered dataset suggests some qualitative considerations on the mechanisms controlling tourmaline compositions at the regional scale. The highest Fe3+ concentrations occur in samples from Rudňany and Gretla in the external part of Gemeric unit, suggesting higher oxidation during longer transport of fluids. We propose that the determined XFe in the samples are correlated with the compositions of the host rocks, as

  9. Investigation of planar channeling radiation on diamond and quartz crystals at electron energies between 14 and 34 MeV and probing the influence of ultrasonic waves on channeling radiation

    International Nuclear Information System (INIS)

    Azadegan, B.

    2007-01-01

    Measurements of planar channeling radiation (CR) have been performed at the electron beam of ELBE within an energy range between 14 and 34 MeV and for thicknesses of the diamond crystals between 42.5 and 500 μm. Absolute CR photon yields have for the first time been obtained for the above given ranges of electron energy and crystal thickness. The square-root dependence of the planar CR photon yield on the thickness of diamond crystals has been confirmed. A systematic quantitative investigation of the influence of the crystal thickness on the CR line shape has for the first time been performed. The mean-squared multiple-scattering angle effective for planar CR observed in forward direction has been found to be weaker as assumed from scattering in amorphous targets. Scaling laws deduced from the measured CR data are of advantage for the operation of a CR source. The second part of this thesis deals with the possibility of stimulation of CR emission by means of ultrasonic vibrations excited in a piezoelectric single crystal. Since the knowledge of the CR spectra generated on undisturbed quartz crystals is a necessary precondition for some investigation of the influence of US, planar CR has for the first time been measured at medium electron energies for a variety of planes in quartz. As a consequence of the hexagonal structure of this crystal, relative intense CR could be registered even out of planes with indices larger than one. On the base of the non-linear optics method, occupation functions and spectral distributions of planar CR have been calculated for channeling of 20 MeV electrons in the (01 anti 15) plane of a 20 μm thick quartz crystal at resonant influence of ultrasound (US). The resonance frequencies have been deduced from the measurements of CR spectra performed on quartz. First experimental investigations of the influence of US on CR started at ELBE aimed at the study of the effect of non-resonant ultrasonic vibrations excited in a 500 μm thick

  10. Investigation of planar channeling radiation on diamond and quartz crystals at electron energies between 14 and 34 MeV and probing the influence of ultrasonic waves on channeling radiation

    Energy Technology Data Exchange (ETDEWEB)

    Azadegan, B.

    2007-11-15

    Measurements of planar channeling radiation (CR) have been performed at the electron beam of ELBE within an energy range between 14 and 34 MeV and for thicknesses of the diamond crystals between 42.5 and 500 {mu}m. Absolute CR photon yields have for the first time been obtained for the above given ranges of electron energy and crystal thickness. The square-root dependence of the planar CR photon yield on the thickness of diamond crystals has been confirmed. A systematic quantitative investigation of the influence of the crystal thickness on the CR line shape has for the first time been performed. The mean-squared multiple-scattering angle effective for planar CR observed in forward direction has been found to be weaker as assumed from scattering in amorphous targets. Scaling laws deduced from the measured CR data are of advantage for the operation of a CR source. The second part of this thesis deals with the possibility of stimulation of CR emission by means of ultrasonic vibrations excited in a piezoelectric single crystal. Since the knowledge of the CR spectra generated on undisturbed quartz crystals is a necessary precondition for some investigation of the influence of US, planar CR has for the first time been measured at medium electron energies for a variety of planes in quartz. As a consequence of the hexagonal structure of this crystal, relative intense CR could be registered even out of planes with indices larger than one. On the base of the non-linear optics method, occupation functions and spectral distributions of planar CR have been calculated for channeling of 20 MeV electrons in the (01 anti 15) plane of a 20 {mu}m thick quartz crystal at resonant influence of ultrasound (US). The resonance frequencies have been deduced from the measurements of CR spectra performed on quartz. First experimental investigations of the influence of US on CR started at ELBE aimed at the study of the effect of non-resonant ultrasonic vibrations excited in a 500 {mu}m thick

  11. Hydrogen speciation in synthetic quartz

    Science.gov (United States)

    Aines, R.D.; Kirby, S.H.; Rossman, G.R.

    1984-01-01

    The dominant hydrogen impurity in synthetic quartz is molecular H2O. H-OH groups also occur, but there is no direct evidence for the hydrolysis of Si-O-Si bonds to yield Si-OH HO-Si groups. Molecular H2O concentrations in the synthetic quartz crystals studied range from less than 10 to 3,300 ppm (H/Si), and decrease smoothly by up to an order of magnitude with distance away from the seed. OH- concentrations range from 96 to 715 ppm, and rise smoothly with distance away from the seed by up to a factor of three. The observed OH- is probably all associated with cationic impurities, as in natural quartz. Molecular H2O is the dominant initial hydrogen impurity in weak quartz. The hydrolytic weakening of quartz may be caused by the transformation H2O + Si-O-Si ??? 2SiOH, but this may be a transitory change with the SiOH groups recombining to form H2O, and the average SiOH concentration remaining very low. Synthetic quartz is strengthened when the H2O is accumulated into fluid inclusions and cannot react with the quartz framework. ?? 1984 Springer-Verlag.

  12. Bacterial interactions with proteins and cells relevant to the development of life-threatening endocarditis studied by use of a quartz-crystal microbalance.

    Science.gov (United States)

    Krajewski, Stefanie; Rheinlaender, Johannes; Ries, Philip; Canjuga, Denis; Mack, Carmen; Scheideler, Lutz; Schäffer, Tilman E; Geis-Gerstorfer, Jürgen; Wendel, Hans-Peter; Rupp, Frank

    2014-05-01

    Implant-related infections are a major challenge in clinical routine because of severe complications, for example infective endocarditis (IE). The purpose of this study was to investigate the real-time interaction of S. gordonii with proteins and cells important in the development of IE, in a flow system, by use of a quartz-crystal microbalance (QCM). Acoustic sensors were biologically modified by preconditioning with sterile saliva, platelet-poor plasma (PPP), or platelet-rich plasma (PRP), followed then by perfusion of a bacterial suspension. After perfusion, additional fluorescence and scanning electron microscopic (SEM) studies were performed. The surface structure of S. gordonii was analyzed by atomic force microscopy (AFM). Compared with S. gordonii adhesion on the abiotic sensor surface following normal mass loading indicated by a frequency decrease, adhesion on saliva, PPP, or PRP-conditioned sensors resulted in an increase in frequency. Furthermore, adhesion induced slightly increased damping signals for saliva and PPP-coated sensors but a decrease upon bacterial adhesion to PRP, indicating the formation of a more rigid biofilm. Microscopic analysis confirmed the formation of dense and vital bacterial layers and the aggregation of platelets and bacteria. In conclusion, our study shows that the complex patterns of QCM output data observed are strongly dependent on the biological substrate and adhesion mechanisms of S. gordonii. Overall, QCM sheds new light on the pathways of such severe infections as IE.

  13. Mucoadhesion vs mucus permeability of thiolated chitosan polymers and their resulting nanoparticles using a quartz crystal microbalance with dissipation (QCM-D).

    Science.gov (United States)

    Oh, Sejin; Borrós, Salvador

    2016-11-01

    The aim of this present study was to evaluate the combination properties between mucoadhesion/mucus permeability of thiolated chitosans (TC) and their resulting nanoparticles using a quartz crystal microbalance with dissipation (QCM-D). The QCM-D experiments were conducted at pH 4 or 6.8 to assess the interaction between thiolated polymers, with low (TCL), medium (TCM) and high (TCH) contents of free thiol groups, and native porcine gastric mucin (NPGM). TCL was chosen for further carriers as it showed higher permeability into the NPGM layer compared to TCM and TCH. In this study, we describe a formulation of a novel carrier comprised by positively charged TCL, negatively charged DNA and degradable oligopeptide-modified poly(β-amino ester)s (PBAEs), which were employed in order to approach for tuning particle size and surface charge of complexes. TCL/PBAE complexes with or without DNA were characterized using dynamic light scattering. Mechanism of adsorption or permeation of the TCL/PBAE/DNA complexes into the NPGM barrier was investigated with QCM-D, which is a highly sensitive technique for studying nanomechanical (viscoelastic) changes of the substrates. This work might provide that the QCM-D technique would be a promising method to monitor the dynamic behaviour between complexes and NPGM. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. A Simple Method for the Detection of Long-Chain Fatty Acids in an Anaerobic Digestate Using a Quartz Crystal Sensor

    Directory of Open Access Journals (Sweden)

    Takuro Kobayashi

    2016-12-01

    Full Text Available In anaerobic digestion (AD, long-chain fatty acids (LCFAs produced by hydrolysis of lipids, exhibit toxicity against microorganisms when their concentration exceeds several millimolar. An absorption detection system using a quartz crystal microbalance (QCM was developed to monitor the LCFA concentration during an anaerobic digester’s operation treating oily organic waste. The dissociation of the LCFAs considerably improved the sensor response and, moreover, enabled it to specifically detect LCFA from the mixture of LCFA and triglyceride. Under alkaline conditions, the frequency-shift rates of the QCM sensor linearly increased in accordance with palmitic acid concentration in the range of 0–100 mg/L. Frequency changes caused by anaerobic digestate samples were successfully measured after removing suspended solids and adjusting the pH to 10.7. Finally, the QCM measurements for digestate samples demonstrated that frequency-shift rates are highly correlated with LCFA concentrations, which confirmed that the newly developed QCM sensor is helpful for LCFA monitoring in terms of rapidness and usability.

  15. Trend of telomerase activity change during human iPSC self-renewal and differentiation revealed by a quartz crystal microbalance based assay

    Science.gov (United States)

    Zhou, Yitian; Zhou, Ping; Xin, Yinqiang; Wang, Jie; Zhu, Zhiqiang; Hu, Ji; Wei, Shicheng; Ma, Hongwei

    2014-11-01

    Telomerase plays an important role in governing the life span of cells for its capacity to extend telomeres. As high activity of telomerase has been found in stem cells and cancer cells specifically, various methods have been developed for the evaluation of telomerase activity. To overcome the time-consuming procedures and complicated manipulations of existing methods, we developed a novel method named Telomeric Repeat Elongation Assay based on Quartz crystal microbalance (TREAQ) to monitor telomerase activity during the self-renewal and differentiation of human induced pluripotent stem cells (hiPSCs). TREAQ results indicated hiPSCs possess invariable telomerase activity for 11 passages on Matrigel and a steady decline of telomerase activity when differentiated for different periods, which is confirmed with existing golden standard method. The pluripotency of hiPSCs during differentiation could be estimated through monitoring telomerase activity and compared with the expression levels of markers of pluripotency gene via quantitative real time PCR. Regular assessment for factors associated with pluripotency or stemness was expensive and requires excessive sample consuming, thus TREAQ could be a promising alternative technology for routine monitoring of telomerase activity and estimate the pluripotency of stem cells.

  16. 1-Butyl-3-Methylimidazolium Tetrafluoroborate Film as a Highly Selective Sensing Material for Non-Invasive Detection of Acetone Using a Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Wenyan Tao

    2017-01-01

    Full Text Available Breath acetone serves as a biomarker for diabetes. This article reports 1-butyl-3-methylimidazolium tetrafluoroborate ([bmim][BF4], a type of room temperature ionic liquid (RTIL, as a selective sensing material for acetone. The RTIL sensing layer was coated on a quartz crystal microbalance (QCM for detection. The sensing mechanism is based on a decrease in viscosity and density of the [bmim][BF4] film due to the solubilization of acetone leading to a positive frequency shift in the QCM. Acetone was detected with a linear range from 7.05 to 750 ppmv. Sensitivity and limit of detection were found to be 3.49 Hz/ppmv and 5.0 ppmv, respectively. The [bmim][BF4]-modified QCM sensor demonstrated anti-interference ability to commonly found volatile organic compounds in breath, e.g., isoprene, 1,2-pentadiene, d-limonene, and dl-limonene. This technology is useful for applications in non-invasive early diabetic diagnosis.

  17. Highly selective detection of single-nucleotide polymorphisms using a quartz crystal microbalance biosensor based on the toehold-mediated strand displacement reaction.

    Science.gov (United States)

    Wang, Dingzhong; Tang, Wei; Wu, Xiaojie; Wang, Xinyi; Chen, Gengjia; Chen, Qiang; Li, Na; Liu, Feng

    2012-08-21

    Toehold-mediated strand displacement reaction (SDR) is first introduced to develop a simple quartz crystal microbalance (QCM) biosensor without an enzyme or label at normal temperature for highly selective and sensitive detection of single-nucleotide polymorphism (SNP) in the p53 tumor suppressor gene. A hairpin capture probe with an external toehold is designed and immobilized on the gold electrode surface of QCM. A successive SDR is initiated by the target sequence hybridization with the toehold domain and ends with the unfolding of the capture probe. Finally, the open-loop capture probe hybridizes with the streptavidin-coupled reporter probe as an efficient mass amplifier to enhance the QCM signal. The proposed biosensor displays remarkable specificity to target the p53 gene fragment against single-base mutant sequences (e.g., the largest discrimination factor is 63 to C-C mismatch) and high sensitivity with the detection limit of 0.3 nM at 20 °C. As the crucial component of the fabricated biosensor for providing the high discrimination capability, the design rationale of the capture probe is further verified by fluorescence sensing and atomic force microscopy imaging. Additionally, a recovery of 84.1% is obtained when detecting the target sequence in spiked HeLa cells lysate, demonstrating the feasibility of employing this biosensor in detecting SNPs in biological samples.

  18. Probing Interfacial Friction and Dissipation in Granular Gold­ Nickel Alloys with a Quartz Crystal Oscillator in an External Magnetic Field

    Science.gov (United States)

    Stevens, K. M.; Krim, J.

    2015-03-01

    We present here a quartz crystal microbalance study of two-phase gold nickel alloys whose internal granular properties are probed by exposure to a fluctuating external magnetic field. The work is motivated by prior studies demonstrating that granular two-phase materials exhibited lower friction and wear than solid solution alloys with identical compositions. In particular, we report a ``flexing'' effect which appears when an external magnetic field is applied, and is manifested as a decrease in the magnitude of oscillation amplitude that is synchronized with the applied field; the effect is not seen on the complimentary solid solution samples. The effect is consistent with internal interfacial friction between nickel and gold grains, indicating a degree of freedom which may decrease friction even in the absence of an external magnetic field. This is supported through analysis of energy dissipation in the system, using the Butterworth­-Van Dyke equivalent circuit model. Data and interpretation are also presented that rule out alternate explanations such as giant magnetoresistance and/or other resistive phenomenon within the film. Funding provided by NSF DMR0805204. Thanks to L. Pan for sample preparation.

  19. Particle Characterization for a Protein Drug Product Stored in Pre-Filled Syringes Using Micro-Flow Imaging, Archimedes, and Quartz Crystal Microbalance with Dissipation.

    Science.gov (United States)

    Zheng, Songyan; Puri, Aastha; Li, Jinjiang; Jaiswal, Archana; Adams, Monica

    2017-01-01

    Micro-flow imaging (MFI) has been used for formulation development for analyzing sub-visible particles. Archimedes, a novel technique for analyzing sub-micron particles, has been considered as an orthogonal method to currently existing techniques. This study utilized these two techniques to investigate the effectiveness of polysorbate (PS-80) in mitigating the particle formation of a therapeutic protein formulation stored in silicone oil-coated pre-filled syringes. The results indicated that PS-80 prevented the formation of both protein and silicone oil particles. In the case of protein particles, PS-80 might involve in the interactions with the hydrophobic patches of protein, air bubbles, and the stressed surfaces of silicone oil-coated pre-filled syringes. Such interactions played a role in mitigating the formation of protein particles. Subsequently, quartz crystal microbalance with dissipation (QCM-D) was utilized to characterize the interactions associated with silicone oil, protein, and PS-80 in the solutions. Based on QCM-D results, we proposed that PS-80 likely formed a layer on the interior surfaces of syringes. As a result, the adsorbed PS-80 might block the leakage of silicone oil from the surfaces to solution so that the silicone oil particles were mitigated at the presence of PS-80. Overall, this study demonstrated the necessary of utilizing these three techniques cooperatively in order to better understand the interfacial role of PS-80 in mitigating the formation of protein and silicone oil particles.

  20. Electrochemistry, surface plasmon resonance, and quartz crystal microbalance: an associative study on cytochrome c adsorption on pyridine tail-group monolayers on gold.

    Science.gov (United States)

    Paulo, Tércio de F; de Sousa, Ticyano P; de Abreu, Dieric S; Felício, Nathalie H; Bernhardt, Paul V; Lopes, Luiz G de F; Sousa, Eduardo H S; Diógenes, Izaura C N

    2013-07-25

    Quartz crystal microbalance (QCM), surface plasmon resonance (SPR), and electrochemistry techniques were used to study the electron-transfer (ET) reaction of cytochrome c (Cyt c) on gold surfaces modified with thionicotinamide, thioisonicotinamide, 4-mercaptopyridine, 5-(4-pyridyl)-1,3,4-oxadiazole-2-thiol, 5-phenyl-1,3,4-oxadiazole-2-thiol, 4,4'-bipyridine, and 4,4'-dithiopyridine. The electrochemical results showed that the ET process is complex, being chiefly diffusional with steps depending on the orientation of the pyridine or phenyl tail group of the modifiers. The correlation between the electrochemical results and those acquired by SPR and QCM indicated the presence of an adlayer of Cyt c adsorbed on the thiolate SAMs. This adlayer, although being not electroactive, is essential to assess the ET reaction of Cyt c in solution. The results presented in this work are consistent with the statement (Feng, Z. Q.; Imabayashi, S.; Kakiuchi, T.; Niki, K. J. Electroanal. Chem. 1995, 394, 149-154) that the ET reaction of Cyt c can be explained in terms of the through-bond tunneling mechanism.

  1. Molecularly imprinted polymer based quartz crystal microbalance sensor system for sensitive and label-free detection of synthetic cannabinoids in urine.

    Science.gov (United States)

    Battal, Dilek; Akgönüllü, Semra; Yalcin, M Serkan; Yavuz, Handan; Denizli, Adil

    2018-07-15

    Herein, we prepared a novel quartz crystal microbalance (QCM) sensor for synthetic cannabinoids (JWH-073, JWH-073 butanoic acid, JWH-018 and JWH-018 pentanoic acid,) detection. Firstly, the synthetic cannabinoid (SCs) imprinted (MIP) and non-imprinted (NIP) nanoparticles were synthesized by mini-emulsion polymerization system. The SCs-imprinted nanoparticles were first characterized by SEM, TEM, zeta-size and FTIR-ATR analysis and then were dropped onto the gold QCM surface. The SCs-imprinted QCM sensor was characterized by an ellipsometer, contact angle, and AFM. The limit of detection was found as 0.3, 0.45, 0.4, 0.2 pg/mL JWH-018, JWH-073, JWH-018 pentanoic acid and JWH-073 butanoic acid, respectively. The selectivity of the SCs-imprinted QCM sensor was shown by using JWH-018, JWH-018 pentanoic acid, JWH-073 and JWH-073 butanoic acid. According to the results, the SCs-imprinted QCM sensors show highly selective and sensitive in a broad range of synthetic cannabinoid concentrations (0.0005-1.0 ng/mL) in both aqueous and synthetic urine solutions. Copyright © 2018 Elsevier B.V. All rights reserved.

  2. A quick responding quartz crystal microbalance sensor array based on molecular imprinted polyacrylic acids coating for selective identification of aldehydes in body odor.

    Science.gov (United States)

    Jha, Sunil K; Hayashi, Kenshi

    2015-03-01

    In present work, a novel quartz crystal microbalance (QCM) sensor array has been developed for prompt identification of primary aldehydes in human body odor. Molecularly imprinted polymers (MIP) are prepared using the polyacrylic acid (PAA) polymer matrix and three organic acids (propenoic acid, hexanoic acid and octanoic acid) as template molecules, and utilized as QCM surface coating layer. The performance of MIP films is characterized by 4-element QCM sensor array (three coated with MIP layers and one with pure PAA for reference) dynamic and static responses to target aldehydes: hexanal, heptanal, and nonanal in single, binary, and tertiary mixtures at distinct concentrations. The target aldehydes were selected subsequent to characterization of body odor samples with solid phase-micro extraction gas chromatography mass spectrometer (SPME-GC-MS). The hexanoic acid and octanoic acid imprinted PAA exhibit fast response, and better sensitivity, selectivity and reproducibility than the propenoic acid, and non-imprinted PAA in array. The response time and recovery time for hexanoic acid imprinted PAA are obtained as 5 s and 12 s respectively to typical concentrations of binary and tertiary mixtures of aldehydes using the static response. Dynamic sensor array response matrix has been processed with principal component analysis (PCA) for visual, and support vector machine (SVM) classifier for quantitative identification of target odors. Aldehyde odors were identified successfully in principal component (PC) space. SVM classifier results maximum recognition rate 79% for three classes of binary odors and 83% including single, binary, and tertiary odor classes in 3-fold cross validation. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus

    International Nuclear Information System (INIS)

    Chen, S-H; Chuang, Y-C; Lu, Y-C; Lin, H-C; Yang, Y-L; Lin, C-S

    2009-01-01

    Dengue virus (DENV) is nowadays the most important arthropod-spread virus affecting humans existing in more than 100 countries worldwide. A rapid and sensitive detection method for the early diagnosis of infectious dengue virus urgently needs to be developed. In the present study, a circulating-flow quartz crystal microbalance (QCM) biosensing method combining oligonucleotide-functionalized gold nanoparticles (i.e. AuNP probes) used to detect DENV has been established. In the DNA-QCM method, two kinds of specific AuNP probes were linked by the target sequences onto the QCM chip to amplify the detection signal, i.e. oscillatory frequency change (ΔF) of the QCM sensor. The target sequences amplified from the DENV genome act as a bridge for the layer-by-layer AuNP probes' hybridization in the method. Besides being amplifiers of the detection signal, the specific AuNP probes used in the DNA-QCM method also play the role of verifiers to specifically recognize their target sequences in the detection. The effect of four AuNP sizes on the layer-by-layer hybridization has been evaluated and it is found that 13 nm AuNPs collocated with 13 nm AuNPs showed the best hybridization efficiency. According to the nanoparticle application, the DNA-QCM biosensing method was able to detect dengue viral RNA in virus-contaminated serum as plaque titers being 2 PFU ml -1 and a linear correlation (R 2 = 0.987) of ΔF versus virus titration from 2 x 10 0 to 2 x 10 6 PFU ml -1 was found. The sensitivity and specificity of the present DNA-QCM method with nanoparticle technology showed it to be comparable to the fluorescent real-time PCR methods. Moreover, the method described herein was shown to not require expensive equipment, was label-free and highly sensitive.

  4. Transient kinetic studies of pH-dependent hydrolyses by exo-type carboxypeptidase P on a 27-MHz quartz crystal microbalance.

    Science.gov (United States)

    Furusawa, Hiroyuki; Takano, Hiroki; Okahata, Yoshio

    2008-02-15

    pH-Dependent kinetic parameters (k(on), k(off), and k(cat)) of protein (myoglobin) hydrolyses catalyzed by exo-enzyme (carboxypeptidase P, CPP) were obtained by using a protein-immobilized quartz crystal microbalance (QCM) in acidic aqueous solutions. The formation of the enzyme-substrate (ES) complex (k(on)), the decay of the ES complex (k(off)), and the formation of the product (k(cat)) could be analyzed by transient kinetics as mass changes on the QCM plate. The Kd (k(off)/k(on)) value was different from the Michaelis constant Km calculated from (k(off) + k(cat))/k(on) due to k(cat) > k(off). The rate-determining step was the binding step (k(on), and the catalytic rate k(cat) was faster than other k(on) and k(off) values. In the range of pH 2.5-5.0, values of k(on) gradually increased with decreasing pH showing a maximum at pH 3.7, values of k(off) were independent of pH, and k(cat) increased gradually with decreasing pH. As a result, the apparent rate constant (k(cat)/Km) showed a maximum at pH 3.7 and gradually increased with decreasing pH. The optimum pH at 3.7 of k(on) is explained by the optimum binding ability of CPP to the COOH terminus of the substrate with hydrogen bonds. The increase of k(cat) at the lower pH correlated with the decrease of alpha-helix contents of the myoglobin substrate on the QCM.

  5. Fabrication of a novel quartz micromachined gyroscope

    Science.gov (United States)

    Xie, Liqiang; Xing, Jianchun; Wang, Haoxu; Wu, Xuezhong

    2015-04-01

    A novel quartz micromachined gyroscope is proposed in this paper. The novel gyroscope is realized by quartz anisotropic wet etching and 3-dimensional electrodes deposition. In the quartz wet etching process, the quality of Cr/Au mask films affecting the process are studied by experiment. An excellent mask film with 100 Å Cr and 2000 Å Au is achieved by optimization of experimental parameters. Crystal facets after etching seriously affect the following sidewall electrodes deposition process and the structure's mechanical behaviours. Removal of crystal facets is successfully implemented by increasing etching time based on etching rate ratios between facets and crystal planes. In the electrodes deposition process, an aperture mask evaporation method is employed to prepare electrodes on 3-dimensional surfaces of the gyroscope structure. The alignments among the aperture masks are realized by the ABM™ Mask Aligner System. Based on the processes described above, a z-axis quartz gyroscope is fabricated successfully.

  6. The impact of water and hydrocarbon concentration on the sensitivity of a polymer-based quartz crystal microbalance sensor for organic compounds

    International Nuclear Information System (INIS)

    Pejcic, Bobby; Crooke, Emma; Doherty, Cara M.; Hill, Anita J.; Myers, Matthew; Qi, Xiubin; Ross, Andrew

    2011-01-01

    Highlights: → The response of a polymer coated QCM sensor is affected by water soaking time. → Polymer-water interfacial processes influence the QCM sensitivity for hydrocarbons. → The QCM sensitivity of high Tg polymer films is affected by plasticization processes. - Abstract: Long-term environmental monitoring of organic compounds in natural waters requires sensors that respond reproducibly and linearly over a wide concentration range, and do not degrade with time. Although polymer coated piezoelectric based sensors have been widely used to detect hydrocarbons in aqueous solution, very little information exists regarding their stability and suitability over extended periods in water. In this investigation, the influence of water aging on the response of various polymer membranes [polybutadiene (PB), polyisobutylene (PIB), polystyrene (PS), polystyrene-co-butadiene (PSB)] was studied using the quartz crystal microbalance (QCM). QCM measurements revealed a modest increase in sensitivity towards toluene for PB and PIB membranes at concentrations above 90 ppm after aging in water for 4 days. In contrast, the sensitivity of PS and PSB coated QCM sensors depended significantly on the toluene concentration and increased considerably at concentrations above 90 ppm after aging in water for 4 days. Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) showed that there is a change in the sorption mechanism at higher toluene levels for PS and PSB. Positron annihilation lifetime spectroscopy (PALS) studies were performed to investigate the free volume properties of all polymers and to monitor any changes in the free volume size and distribution due to water and toluene exposure. The PALS did not detect any considerable variation in the free volume properties of the polymer films as a function of solution composition and soaking time, implying that viscoelastic and/or interfacial processes (i.e. surface area changes) are probably responsible

  7. A method of layer-by-layer gold nanoparticle hybridization in a quartz crystal microbalance DNA sensing system used to detect dengue virus

    Energy Technology Data Exchange (ETDEWEB)

    Chen, S-H; Chuang, Y-C; Lu, Y-C; Lin, H-C; Yang, Y-L; Lin, C-S [Department of Biological Science and Technology, National Chiao Tung University, Hsinchu 30068, Taiwan (China)], E-mail: lincs@mail.nctu.edu.tw

    2009-05-27

    Dengue virus (DENV) is nowadays the most important arthropod-spread virus affecting humans existing in more than 100 countries worldwide. A rapid and sensitive detection method for the early diagnosis of infectious dengue virus urgently needs to be developed. In the present study, a circulating-flow quartz crystal microbalance (QCM) biosensing method combining oligonucleotide-functionalized gold nanoparticles (i.e. AuNP probes) used to detect DENV has been established. In the DNA-QCM method, two kinds of specific AuNP probes were linked by the target sequences onto the QCM chip to amplify the detection signal, i.e. oscillatory frequency change ({delta}F) of the QCM sensor. The target sequences amplified from the DENV genome act as a bridge for the layer-by-layer AuNP probes' hybridization in the method. Besides being amplifiers of the detection signal, the specific AuNP probes used in the DNA-QCM method also play the role of verifiers to specifically recognize their target sequences in the detection. The effect of four AuNP sizes on the layer-by-layer hybridization has been evaluated and it is found that 13 nm AuNPs collocated with 13 nm AuNPs showed the best hybridization efficiency. According to the nanoparticle application, the DNA-QCM biosensing method was able to detect dengue viral RNA in virus-contaminated serum as plaque titers being 2 PFU ml{sup -1} and a linear correlation (R{sup 2} = 0.987) of {delta}F versus virus titration from 2 x 10{sup 0} to 2 x 10{sup 6} PFU ml{sup -1} was found. The sensitivity and specificity of the present DNA-QCM method with nanoparticle technology showed it to be comparable to the fluorescent real-time PCR methods. Moreover, the method described herein was shown to not require expensive equipment, was label-free and highly sensitive.

  8. Ferrobielastic twinning in irradiated quartz

    International Nuclear Information System (INIS)

    Shiau, S.M.

    1986-01-01

    Cultured quartz is usually free from electrical twinning; however, it may occur if the seed crystal is twinned or if undue applied forces are exerted on the crystal. Ferrobielastic twinning was studied optically (photoelastic effect) and electrically (piezoelectric effect). At room temperature, twins were perceptible at stresses of about 2.l5 x 10 8 N/m 2 , and crystals switched from their original states to the alternative twin states at stresses about 5.0 x 10 8 N/m 2 (called coercive stress). The decrease in coercive stress with increasing temperature was observed, and these coercive stresses become very low as temperatures reach to 300 0 C. The effects of irradiation on the twinning in quartz were also studied. The presence of defects produced by irradiation was utilized to pin the domain wall motion. Both neutrons and gamma rays were employed. The stress required to nucleate an appreciable volume of twins is about twice as high for irradiated crystals than for those unirradiated. This result demonstrated that the irradiated crystals can tolerate higher stresses. However, the coercive stress for complete switch-over was not much different for irradiated and unirradiated crystals. It appears that the defects caused by irradiation eliminate the initial twinning events but do not affect switch-over

  9. Hydrogen sensing method with a quartz sensor

    International Nuclear Information System (INIS)

    Suzuki, A.; Kurokawa, A.; Nonaka, H.

    2006-01-01

    The stability for hydrogen leakage detection was improved by impedance measurement with a quartz sensor (Q-sensor) instead of pressure measurement with a quartz friction pressure gauge (Q-gauge) previously used. Degree of the experimental fluctuation of the impedance from the Q-sensor and of the pressure from the Q-gauge was 0.06 and 0.2 % of each output, thus showing that the Q-sensor measurement was more stable than that by the Q-gauge. Estimated minimum detection limit for hydrogen by the Q-sensor impedance measurement is also improved compared to the Q-gauge pressure measurement. Low hydrogen concentration experiment presented that the Q-sensor impedance measurement detects the 0.05 vol.% hydrogen in air at atmospheric pressure more sensitively than the Q-gauge pressure measurement. It was proved that the Q-sensor impedance measurement was more sensitive and stable as a hydrogen leakage detection method than the Q-gauge pressure measurement. (authors)

  10. Quartz fiber calorimeter

    International Nuclear Information System (INIS)

    Akchurin, N.; Doulas, S.; Ganel, O.; Gershtein, Y.; Gavrilov, V.; Kolosov, V.; Kuleshov, S.; Litvinsev, D.; Merlo, J.-P.; Onel, Y.; Osborne, D.; Rosowsky, A.; Stolin, V.; Sulak, L.; Sullivan, J.; Ulyanov, A.; Wigmans, R.; Winn, D.

    1996-01-01

    A calorimeter with optical quartz fibers embedded into an absorber matrix was proposed for the small angle region of the CMS detector at LHC (CERN). This type of calorimeter is expected to be radiation hard and to produce extremely fast signal. Some results from beam tests of the quartz fiber calorimeter prototype are presented. (orig.)

  11. Impedance Scaling and Impedance Control

    International Nuclear Information System (INIS)

    Chou, W.; Griffin, J.

    1997-06-01

    When a machine becomes really large, such as the Very Large Hadron Collider (VLHC), of which the circumference could reach the order of megameters, beam instability could be an essential bottleneck. This paper studies the scaling of the instability threshold vs. machine size when the coupling impedance scales in a ''normal'' way. It is shown that the beam would be intrinsically unstable for the VLHC. As a possible solution to this problem, it is proposed to introduce local impedance inserts for controlling the machine impedance. In the longitudinal plane, this could be done by using a heavily detuned rf cavity (e.g., a biconical structure), which could provide large imaginary impedance with the right sign (i.e., inductive or capacitive) while keeping the real part small. In the transverse direction, a carefully designed variation of the cross section of a beam pipe could generate negative impedance that would partially compensate the transverse impedance in one plane

  12. Resistive cooling circuits for charged particle traps using crystal resonators

    CERN Document Server

    Kaltenbacher, T; Doser, M; Kellerbauer, A; Pribyl, W

    2011-01-01

    The paper addresses a novel method to couple a signal from charged particles in a Penning trap to a high Q resonant circuit using a crystal resonator. Traditionally the trap capacity is converted into a resonator by means of an inductance. When normal conducting wires (e.g. copper) are applied to build up a coil, the unloaded Q value is limited to a value in the order of 1000. The tuned circuit’s Q factor is directly linked to the input impedance “seen” by the trapped particles at resonance frequency. This parallel resonance impedance is a measure of the efficiency of resistive cooling and thus it should be optimized. We propose here a commercially available crystal resonator since it exhibits a very high Q value and a parallel resonance impedance of several MOhm. The possibility to tune the parallel resonance frequency of the quartz results in filter behavior that allows covering a broad range of frequencies.

  13. Formation of cogenetic quartz and nepheline syenites

    Science.gov (United States)

    Foland, K. A.; Landoll, J. D.; Henderson, C. M. B.; Chen, Jiangfeng

    1993-02-01

    Understanding the processes involved in the formation of cogenetic silica-undersaturated and silica-saturated felsic rocks in alkaline igneous complexes has been a long-standing enigma because of constraints imposed by phase equilibria relationships. This problem is discussed in general drawing upon relationships at two magmatic centers: Marangudzi in Zimbabwe and Mt. Brome in Quebec, Canada. At each locality, cogenetic quartz and nepheline syenites appear to be derived from common critically undersaturated magmas. Strontium and neodymium isotope results indicate that quartz syenites bear the signatures of substantial amounts of crustal assimilation whereas nepheline syenites lack or display lesser effects. In the model outlined, quartz syenite melts develop from felsic silica undersaturated magmas by assimilation of granitic crust coupled with fractional crystallization whereas nepheline syenites form without large amounts of contamination. This model is compatible with the constraints imposed by phase equilibria.

  14. Impedance method for measuring shear elasticity of liquids

    Science.gov (United States)

    Badmaev, B. B.; Dembelova, T. S.; Damdinov, B. B.; Gulgenov, Ch. Zh.

    2017-11-01

    Experimental results of studying low-frequency (74 kHz) shear elasticity of polymer liquids by the impedance method (analogous to the Mason method) are presented. A free-volume thick liquid layer is placed on the horizontal surface of a piezoelectric quartz crystal with dimensions 34.7 × 12 × 5.5 cm. The latter performs tangential vibrations at resonance frequency. The liquid layer experiences shear strain, and shear waves should propagate in it. From the theory of the method, it follows that, with an increase in the layer thickness, both real and imaginary resonance frequency shifts should exhibit damped oscillations and tend to limiting values. For the liquids under study, the imaginary frequency shift far exceeds the real one, which testifies to the presence of bulk shear elasticity.

  15. Combined atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and quartz crystal microbalance (QCM) studies of glucose oxidase (GOx) immobilised onto self-assembled monolayer on the gold film

    International Nuclear Information System (INIS)

    Losic, D.; Shapter, J.; Gooding, J.; Erokin, P.; Short, K.

    1999-01-01

    In fabrication of biosensors, self-assembled monolayers (SAM) are an attractive method of immobilising enzymes at electrode surface since it allows precise control over the amount and spatial distribution of the immobilized enzyme. The covalent attachment of glucose oxidase (GOx) to a carboxylic terminated SAM chemisorbed onto gold films was achieved via carbodiimide activation of the carboxylic acids to a reactive intermediate susceptible to nucleophilic attack by amines on free lysine chains of the enzyme. Atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS) and quartz crystal microbalance (QCM) measurements were used for characterisation of GOx modified gold surfaces. Tapping mode AFM studies have revealed that GOx molecules form slightly disordered arrays of pentagonal or hexagonal clusters. Observed features of immobilised GOx are distributed as a submonolayer on the SAM surface which has allowed visualisation of native and unfolded enzyme structure. The presence of the SAM and enzyme on the gold surface was detected by XPS spectroscopy. Spectra show typical peaks for the C 1s, O 1s and N 1s regions. A kinetic study of the adsorption of GOx onto activated SAM using in-situ QCM allowed determination the amount of immobilised GOx on the layer and consequently the optimal immobilisation conditions. Performance parameters of the biosensor such as sensitivity to glucose concentration as a function of enzyme loading were evaluated amperometrically using the redox mediator p-benzoquinone

  16. The use of a quartz crystal microbalance as an analytical tool to monitor particle/surface and particle/particle interactions under dry ambient and pressurized conditions: a study using common inhaler components.

    Science.gov (United States)

    Turner, N W; Bloxham, M; Piletsky, S A; Whitcombe, M J; Chianella, I

    2016-12-19

    Metered dose inhalers (MDI) and multidose powder inhalers (MPDI) are commonly used for the treatment of chronic obstructive pulmonary diseases and asthma. Currently, analytical tools to monitor particle/particle and particle/surface interaction within MDI and MPDI at the macro-scale do not exist. A simple tool capable of measuring such interactions would ultimately enable quality control of MDI and MDPI, producing remarkable benefits for the pharmaceutical industry and the users of inhalers. In this paper, we have investigated whether a quartz crystal microbalance (QCM) could become such a tool. A QCM was used to measure particle/particle and particle/surface interactions on the macroscale, by additions of small amounts of MDPI components, in the powder form into a gas stream. The subsequent interactions with materials on the surface of the QCM sensor were analyzed. Following this, the sensor was used to measure fluticasone propionate, a typical MDI active ingredient, in a pressurized gas system to assess its interactions with different surfaces under conditions mimicking the manufacturing process. In both types of experiments the QCM was capable of discriminating interactions of different components and surfaces. The results have demonstrated that the QCM is a suitable platform for monitoring macro-scale interactions and could possibly become a tool for quality control of inhalers.

  17. In Situ Adsorption Studies at the Solid/Liquid Interface: Characterization of Biological Surfaces and Interfaces Using Sum Frequency Generation Vibrational Spectroscopy, Atomic Force Microscopy, and Quartz Crystal Microbalance

    International Nuclear Information System (INIS)

    Phillips, D.C.

    2006-01-01

    Sum frequency generation (SFG) vibrational spectroscopy, atomic force microscopy (AFM), and quartz crystal microbalance (QCM) have been used to study the molecular surface structure, surface topography and mechanical properties, and quantitative adsorbed amount of biological molecules at the solid-liquid interface. The molecular-level behavior of designed peptides adsorbed on hydrophobic polystyrene and hydrophilic silica substrates has been examined as a model of protein adsorption on polymeric biomaterial surfaces. Proteins are such large and complex molecules that it is difficult to identify the features in their structure that lead to adsorption and interaction with solid surfaces. Designed peptides which possess secondary structure provide simple model systems for understanding protein adsorption. Depending on the amino acid sequence of a peptide, different secondary structures (α-helix and β-sheet) can be induced at apolar (air/liquid or air/solid) interfaces. Having a well-defined secondary structure allows experiments to be carried out under controlled conditions, where it is possible to investigate the affects of peptide amino acid sequence and chain length, concentration, buffering effects, etc. on adsorbed peptide structure. The experiments presented in this dissertation demonstrate that SFG vibrational spectroscopy can be used to directly probe the interaction of adsorbing biomolecules with a surface or interface. The use of well designed model systems aided in isolation of the SFG signal of the adsorbing species, and showed that surface functional groups of the substrate are sensitive to surface adsorbates. The complementary techniques of AFM and QCM allowed for deconvolution of the effects of surface topography and coverage from the observed SFG spectra. Initial studies of biologically relevant surfaces are also presented: SFG spectroscopy was used to study the surface composition of common soil bacteria for use in bioremediation of nuclear waste

  18. In Situ Adsorption Studies at the Solid/Liquid Interface:Characterization of Biological Surfaces and Interfaces Using SumFrequency Generation Vibrational Spectroscopy, Atomic Force Microscopy,and Quartz Crystal Microbalance

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Diana Christine [Univ. of California, Berkeley, CA (United States)

    2006-01-01

    Sum frequency generation (SFG) vibrational spectroscopy, atomic force microscopy (AFM), and quartz crystal microbalance (QCM) have been used to study the molecular surface structure, surface topography and mechanical properties, and quantitative adsorbed amount of biological molecules at the solid-liquid interface. The molecular-level behavior of designed peptides adsorbed on hydrophobic polystyrene and hydrophilic silica substrates has been examined as a model of protein adsorption on polymeric biomaterial surfaces. Proteins are such large and complex molecules that it is difficult to identify the features in their structure that lead to adsorption and interaction with solid surfaces. Designed peptides which possess secondary structure provide simple model systems for understanding protein adsorption. Depending on the amino acid sequence of a peptide, different secondary structures (α-helix and β-sheet) can be induced at apolar (air/liquid or air/solid) interfaces. Having a well-defined secondary structure allows experiments to be carried out under controlled conditions, where it is possible to investigate the affects of peptide amino acid sequence and chain length, concentration, buffering effects, etc. on adsorbed peptide structure. The experiments presented in this dissertation demonstrate that SFG vibrational spectroscopy can be used to directly probe the interaction of adsorbing biomolecules with a surface or interface. The use of well designed model systems aided in isolation of the SFG signal of the adsorbing species, and showed that surface functional groups of the substrate are sensitive to surface adsorbates. The complementary techniques of AFM and QCM allowed for deconvolution of the effects of surface topography and coverage from the observed SFG spectra. Initial studies of biologically relevant surfaces are also presented: SFG spectroscopy was used to study the surface composition of common soil bacteria for use in bioremediation of nuclear waste.

  19. Experimental study of quartz inclusions in garnet at pressures up to 3.0 GPa: evaluating validity of the quartz-in-garnet inclusion elastic thermobarometer

    Science.gov (United States)

    Thomas, Jay B.; Spear, Frank S.

    2018-05-01

    Garnet crystals with quartz inclusions were hydrothermally crystallized from oxide starting materials in piston-cylinder apparatuses at pressures from 0.5 to 3 GPa and temperatures ranging from 700 to 800 °C to study how entrapment conditions affect remnant pressures of quartz inclusions used for quartz-in-garnet (QuiG) elastic thermobarometry. Systematic changes of the 128, 206 and 464 cm-1 Raman band frequencies of quartz were used to determine pressures of quartz inclusions in garnet using Raman spectroscopy calibrations that describe the P-T dependencies of Raman band shifts for quartz under hydrostatic pressure. Within analytical uncertainties, inclusion pressures calculated for each of the three Raman band frequencies are equivalent, which suggests that non-hydrostatic stress effects caused by elastic anisotropy in quartz are smaller than measurement errors. The experimental quartz inclusions have pressures ranging from - 0.351 to 1.247 GPa that span the range of values observed for quartz inclusions in garnets from natural rocks. Quartz inclusion pressures were used to model P-T conditions at which the inclusions could have been trapped. The accuracy of QuiG thermobarometry was evaluated by considering the differences between pressures measured during experiments and pressures calculated using published equation of state parameters for quartz and garnet. Our experimental results demonstrate that Raman measurements performed at room temperature can be used without corrections to estimate garnet crystallization pressures. Calculated entrapment pressures for quartz inclusions in garnet are less than 10% different from pressures measured during the experiments. Because the method is simple to apply with reasonable accuracy, we expect widespread usage of QuiG thermobarometry to estimate crystallization conditions for garnet-bearing silicic rocks.

  20. Quartz Crystal Microbalance with Dissipation Monitoring

    Science.gov (United States)

    2014-11-06

    Hydroxyapatite , 10 nm, Sensors • Biotin Functionalized on Gold Sensors • His-tag Capturing Sensor QCM-D techniques provide answers about...mass and structural changes at the nanoscale level. The instrumentation was used to characterize the interaction between small molecules or polymers...The equipment was used mostly for the investigation of interfaces and processes involving silk or silk-based peptides and inorganic components, to

  1. Electrochemical quartz crystal microbalance analysis of the oxygen reduction reaction on Pt-based electrodes. Part 2: adsorption of oxygen species and ClO4(-) anions on Pt and Pt-Co alloy in HClO4 solutions.

    Science.gov (United States)

    Omura, J; Yano, H; Tryk, D A; Watanabe, M; Uchida, H

    2014-01-14

    To gain deeper insight into the role of adsorbed oxygenated species in the O2 reduction reaction (ORR) kinetics on platinum and platinum-cobalt alloys for fuel cells, we carried out a series of measurements with the electrochemical quartz crystal microbalance (EQCM) and the rotating disk electrode (RDE) in acid solution. The effects of anion adsorption on the activities for the ORR were first assessed in HClO4 and HF electrolyte solutions at various concentrations. In our previous work (Part 1), we reported that the perchlorate anion adsorbs specifically on bulk-Pt, with a Frumkin-Temkin isotherm, that is, a linear relationship between Δm and log[HClO4]. Here, we find that the specific adsorption on the Pt-skin/Pt3Co alloy was significantly stronger than that on bulk-Pt, in line with its modified electronic properties. The kinetically controlled current density j(k) for the O2 reduction at the Pt-skin/Pt3Co-RDE was about 9 times larger than that of the bulk-Pt-RDE in 0.01 M HClO4 saturated with air, but the j(k) values on Pt-skin/Pt3Co decreased with increasing [HClO4] more steeply than in the case of Pt, due to the blocking of the active sites by the specifically adsorbed ClO4(-). We have detected reversible mass changes for one or more adsorbed oxygen-containing species (Ox = O2, O, OH, H2O) on the Pt-skin/Pt3Co-EQCM and Pt-EQCM in O2-saturated and He-purged 0.01 M HClO4 solutions, in which the specific adsorption of ClO4(-) anions was negligible. The coverages of oxygen species θ(Ox) on the Pt-skin/Pt3Co in the potential range from 0.86 to 0.96 V in the O2-saturated solution were found to be larger than those on pure Pt, providing strong evidence that the higher O2 reduction activity on the Pt3Co is correlated with higher θ(Ox), contrary to the conventional view.

  2. Gamma irradiation of quartz from Pannier basin, South America

    Energy Technology Data Exchange (ETDEWEB)

    Enokihara, Cyro T.; Rela, Paulo R. [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)], E-mail: cteiti@ipen.br, E-mail: prela@ipen.br; Guttler, Rainer A.S. [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Geociencias

    2007-07-01

    The use of gamma radiation to induce or enhance color centers in gemstones is a widespread technique and applied worldwide on a industrial scale since at least 1970. The presence of defects and defect structures in quartz from a border region of southern Brazil and Uruguay are the reason for the creation of a new color variety of quartz called 'Prasiolite' in the gem trade. This quartz has a pleasant green color produced by gamma irradiation. The procedures of irradiation at IPEN show that the activation of these color producing defects can be monitored by detailed chemical and spectroscopic analysis. For the first time UV-VIS-NIR spectra of this new color variety of quartz are shown. They revealed special features of these quartz crystals coming from basaltic terranes of the Parana Basin. Contrary to most specimen of quartz from other parts of Brazil, they have such a high water and OH content that they resemble more chalcedony or opal, but not highly crystalline quartz specimens. The cause of the color are broken bonds of Si-OH defining the so-called dangling bonds. (author)

  3. Identification of color development potential of quartz by Raman spectroscopy

    International Nuclear Information System (INIS)

    Alkmim, Danielle G.; Lameiras, Fernando S.; Almeida, Frederico O.T.

    2013-01-01

    Colorless quartz is usually exposed to ionizing radiation (gamma rays or high energy electron beams) to acquire different colors for jewelry. Color development is due to the presence of traces of some elements such as aluminum, iron, hydrogen, lithium, or sodium. Most quartz crystals are extracted colorless from nature and it is necessary to separate those that can develop colors from those that cannot. Irradiation tests can be used to accomplish this separation, but they take a long time. Infrared signature of colorless quartz can also be used. However, infrared spectroscopy is quite expensive, especially when using portable devices. Raman spectroscopy is now available as an inexpensive and portable technique that could provide identification of the samples of colorless quartz still in the field, facilitating the prediction for their economic exploitation. In addition, Raman spectroscopy usually requires a minimum or no sample preparation. This paper presents an investigation of the feasibility of using Raman spectroscopy as a substitute for infrared spectroscopy to predict the potential for color development of quartz. A band at 3595 cm -1 in the Raman shift spectrum was observed only along the c axis of a prasiolite excited by a high power 514 nm laser. This band was not observed in quartz samples that do not develop color after irradiation. Further studies are required to identify the potential for color development by Raman spectroscopy of other types of colorless quartz. (author)

  4. Quartz analysis in gravimetric sampling

    International Nuclear Information System (INIS)

    Rex, D.A.

    1990-01-01

    An overview of the methods employed in the assessment of quartz exposure is provided. The principles and some of the problems associated with each method is discussed. The methods reviewed include wet chemical methods, X-ray diffraction and infrared absorption of which the latter two methods are deemed appropriate for analysing quartz on personal gravimetric collected samples. The implications of combining area samples collected over a six month period, and performing only a single quartz analysis rather than separate analyses, are considered. Finally, various options open to mines with regard to their involvement with quartz analysis are also briefly discussed. 35 refs., 6 figs., 1 tab

  5. crystal

    Science.gov (United States)

    Yu, Yi; Huang, Yisheng; Zhang, Lizhen; Lin, Zhoubin; Sun, Shijia; Wang, Guofu

    2014-07-01

    A Nd3+:Na2La4(WO4)7 crystal with dimensions of ϕ 17 × 30 mm3 was grown by the Czochralski method. The thermal expansion coefficients of Nd3+:Na2La4(WO4)7 crystal are 1.32 × 10-5 K-1 along c-axis and 1.23 × 10-5 K-1 along a-axis, respectively. The spectroscopic characteristics of Nd3+:Na2La4(WO4)7 crystal were investigated. The Judd-Ofelt theory was applied to calculate the spectral parameters. The absorption cross sections at 805 nm are 2.17 × 10-20 cm2 with a full width at half maximum (FWHM) of 15 nm for π-polarization, and 2.29 × 10-20 cm2 with a FWHM of 14 nm for σ-polarization. The emission cross sections are 3.19 × 10-20 cm2 for σ-polarization and 2.67 × 10-20 cm2 for π-polarization at 1,064 nm. The fluorescence quantum efficiency is 67 %. The quasi-cw laser of Nd3+:Na2La4(WO4)7 crystal was performed. The maximum output power is 80 mW. The slope efficiency is 7.12 %. The results suggest Nd3+:Na2La4(WO4)7 crystal as a promising laser crystal fit for laser diode pumping.

  6. Identification of Color Development Potential of Quartz by Raman Spectroscopy

    International Nuclear Information System (INIS)

    Gomides Alkmim, D.; Soares Lameiras, F.

    2013-01-01

    Colorless quartz is usually exposed to ionizing radiation (gamma rays or high energy electron beams) in order to acquire different colors for jewelry. This is due to the presence of traces of some elements such as aluminum, iron, hydrogen, lithium, or sodium, which are responsible for the extrinsic colors developed after irradiation. Most quartz crystals are extracted colorless from nature and it is necessary to separate those that can develop colors from those that cannot. This can be done through irradiation tests, which take a long time. Other option is to collect the infrared signature of colorless quartz. However, infrared spectroscopic analysis is quite expensive, especially when using portable devices. Raman spectroscopy is now available as an inexpensive and portable technique that could provide identification of the samples of colorless quartz still in the field, facilitating the prediction for their economic exploitation. In addition, Raman spectroscopy usually requires a minimum or no sample preparation. This paper presents an investigation of the feasibility of using Raman spectroscopy as a substitute for infrared spectroscopy to predict the potential for color development of quartz. A band at 3595 cm -1 was observed, only along the c axis of a prasiolite excited by a high power 514 nm laser. This band was nor observed in quartz samples that do not develop color after irradiation, hence requiring further studies. (Author)

  7. Advances In Impedance Theory

    International Nuclear Information System (INIS)

    Stupakov, G.

    2009-01-01

    We review recent progress in the following areas of the impedance theory: calculation of impedance of tapers and small angle collimators; optical approximation and parabolic equation for the high-frequency impedance; impedance due to resistive inserts in a perfectly conducting pipe.

  8. Impedance analysis and high temperature conduction mechanism of flux grown Pb(Zn{sub 1/3}Nb{sub 2/3}){sub 0.91}Ti{sub 0.09}O{sub 3} single crystal

    Energy Technology Data Exchange (ETDEWEB)

    Singh, B.K.; Kumar, B. [Crystal Lab., Dept. of Physics and Astrophysics, University of Delhi (India)

    2010-10-15

    The electrical properties of Pb(Zn{sub 1/3} Nb{sub 2/3}){sub 0.91}Ti{sub 0.09}O{sub 3} single crystals over a wide range of frequencies (20 Hz to 2 MHz) and temperature (30 to 490 C) were studied using impedance spectroscopic technique. A strongly frequency dependant Debye type relaxation process in crystals was observed. The activation energy for relaxation was found to be 1.72 eV. The nature of Cole-Cole plot reveals the contribution of only grain (bulk) effect in the sample. The temperature dependant conductivity was found to different in different temperature regions, which shows the presence of different carrier for conduction. The activation energy for conduction in the order of 1.69 eV suggested that the conduction process in higher temperature region is governed by the presence of lead vacancy defect in the sample. Further, the negative temperature thermistor behaviour of the system was explored and various associated parameters were calculated. (copyright 2010 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim) (orig.)

  9. A theoretical interpretation of the antibody-antigen interactions between Salmonella and a thickness shear mode (TSM) quartz resonator

    Science.gov (United States)

    Bailey, Claude Albert

    This dissertation outlines the developmental procedure for a real-time food-borne pathogen detector that uses a thickness shear mode (TSM) quartz resonator. A theory is discussed which provides some understanding of the measured signals obtained from the TSM resonator-based Salmonella detector. The theory explains surface viscosity and mass effects, but has yet to be fully implemented for anomalous bacterial interactions. An equivalent circuit model for an immunochemical coating and its effect on the TSM resonator frequency is presented. The latter part of this dissertation describes immunological experiments with precoated piezoelectric quartz crystals. A highly purified immunological system was used to optimize the immobilization procedure. The use of biosensors is becoming a viable alternative to conventional analysis and promises to experience dramatic growth, especially after their true potential is realized and more cost-effective assays are developed. Concern about the safety of our food and water supplies will undoubtedly stimulate further research, and miniaturized biosensors will be developed for use by safety inspectors, and concerned personnel. A Salmonella detector has been demonstrated consisting of a TSM resonator with antibodies immobilized in a Langmuir Blodgett (LB) film on the surface [3]. Scanning Electron Microscopy (SEM) images of bound Salmonella bacteria to both polished and unpolished TSM resonators were taken to correlate the mass of the bound organism to the Sauerbrey equation. Antigen-antibody interactions change the acoustic resonant properties that are reflected in the sensor frequency response. The Salmonella detector operates in a liquid environment (Salmonella suspended in a phosphate buffered saline solution). The viscous properties of this liquid overlayer could influence the TSM resonator's response. Various liquid media (buffer solutions, chicken exudate, and varying fat contents of milk) were studied as a function of

  10. Relationship of Technological Properties with Dynamic Recrystallization of Quartz on the Example of Objects of the Karelian-Kola Region

    Science.gov (United States)

    Skamnitskaya, Lubov; Rakov, Leonid; Bubnova, Tatyana; Shchiptsov, Vladimir

    2017-12-01

    Despite the significant reserves of quartz raw materials, there is a deficit of high purity quartz. It is due to the strict technical requirements imposed by standards for this type of raw materials and technological properties of quartz, which are determined by the features of the crystal structure. The crystalline structure is of particular importance for the technological properties of quartz, since such important characteristics as the limit of raw material enrichment, dissolution rate in acid, melting point of quartz, etc., are determined. The formation of the crystal structure of quartz under natural conditions is associated with the successive dynamic recrystallization of the mineral. The degree of dynamic recrystallization of quartz reflects the distribution of dispersed impurities. If it is weakly manifested, the dispersed impurities are not displaced from one zone to another, and all quartz microblocks contain approximately the same concentration. In this case, more or less uniform dissolution of various regions of quartz is observed, and the pattern of distribution of submicroscopic inhomogeneities is monotonic. If intensive dynamic recrystallization of quartz takes place, then it causes a significant redistribution of the scattered impurities. Then the treatment in HF leads to the appearance of a contrast pattern of the distribution of submicroscopic inhomogeneities. The details of the crystal structure of quartz in this work were investigated by the electron paramagnetic resonance (EPR) method using the ER-420 “Bruker” spectrometer. In the selected samples of quartz, the concentrations of isomorphic impurities Al and Ti were measured, and the degree of crystallinity D of the mineral was estimated from the EPR spectra of each of them. Thus, the technological properties of quartz are determined by various geological processes. The results of the studies show that when evaluating the prospects of quartz raw materials, it is necessary to take into

  11. Role of Substrate on Quartz Cementation in Quartz Aggregates

    Science.gov (United States)

    Farver, J. R.; Winslow, D.; Onasch, C.

    2010-12-01

    Quartz cementation in quartz aggregates has been experimentally investigated. The starting material was disaggregated detrital quartz grains from the well-sorted, mature St. Peter Sandstone. The ‘as-is’ grains have patches of iron oxide coatings and some have euhedral overgrowths that contain iron oxide dust rims. In addition a set of experiments was run using grains that were cleaned by soaking in sodium hydrosulfite and sodium bisulfate solutions to remove exposed iron oxide coatings. Experimental charges consisted of amorphous silica powder (≈30 mg) to provide a source of silica for the quartz cement, AlCl3 powder (≈3 mg) to provide a tracer for Cathodoluminescence (CL) identification of cement formed during the experiment, 25 wt% NaCl brine solution (≈25 mg) to increase the silica solubility and to better mimic oil field brines, and the natural quartz grains (100-130 mg). The charges were weld-sealed in Au capsules and run in cold-seal pressure vessels at 250°C to 450°C at 150 MPa confining pressure for up to 8 weeks. After the experiments, the samples were vacuum impregnated with a low viscosity epoxy containing a blue dye. After curing, the sample charge was sawn in half along its long axis and one half was polished (to 1 micron diamond paste) for analysis. The nature and amount of quartz cement in the samples were determined by a combination of CL, light microscopy, and scanning electron microscopy. Photomosaics of the samples were created and the amount of cement, porosity, and average grain sizes were determined by point-counting. The cement formed during the experiment was easily recognized from the quartz grains (and previous overgrowths) by the difference in luminescence. The results indicate the amorphous silica powder provides a ready source for silica for quartz cementation due to its greater solubility than the quartz. The cementation rates are rapid (>14% cement formed in 2 weeks at 450°C and >7% in 8 weeks at 250°C). Compared to

  12. Electrochemical characterization of electrolytes and electrodes for lithium-ion batteries. Development of a new measuring method for electrochemical investigations on electrodes with the electrochemical quartz crystal microbalance (EQCM); Elektrochemische Charakterisierung von Elektrolyten und Elektroden fuer Lithium-Ionen-Batterien. Entwicklung einer neuen Messmethode fuer elektrochemische Untersuchungen an Elektroden mit der EQCM

    Energy Technology Data Exchange (ETDEWEB)

    Moosbauer, Dominik Johann

    2010-11-09

    In this work the conductivities of four different lithium salts, LiPF6, LiBF4, LiDFOB, and LiBOB in the solvent mixture EC/DEC (3/7) were investigated. Furthermore, the influence of eight ionic liquids (ILs) as additives on the conductivity and electrochemical stability of lithium salt-based electrolytes was studied. The investigated salts were the well-known lithium LiPF6 and LiDFOB. Conductivity studies were performed over the temperature range (238.15 to 333.15) K. The electrochemical stabilities of the solutions were determined at aluminum electrodes. The salt solubility of LiBF4 and LiDFOB in EC/DEC (3/7) was measured with the quartz crystal microbalance (QCM), a method developed in our group. Moreover, a method to investigate interactions between the electrolyte and electrode components with the electrochemical quartz crystal microbalance (EQCM) was developed. First, investigations of corrosion and passivation effects on aluminum with different lithium salts were performed and masses of deposited products estimated. Therefore, the quartzes were specially prepared with foils. Active materials of cathodes, in this work lithium iron phosphate (LiFePO4), were also investigated with the EQCM by a new method. [German] In dieser Arbeit wurden die Leitfaehigkeiten von vier unterschiedlichen Salzen, LiPF6, LiBF4, LiDFOB und LiBOB in dem Loesemittelgemisch EC/DEC (3/7) untersucht. Des Weiteren wurde der Einfluss von acht Ionischen Fluessigkeiten (ILs) als Additive fuer Lithium-Elektrolyte auf die elektrochemische Stabilitaet und die Leitfaehigkeit studiert. Die untersuchten Salze waren LiPF6 und LiDFOB. Die Leitfaehigkeitsmessungen wurden in einem Temperaturbereich von (238,15 bis 333,15) K durchgefuehrt. Die elektrochemischen Stabilitaeten der Elektrolyte fanden an Aluminium statt. Mit einer an der Arbeitsgruppe entwickelten neuen Methode wurden zudem die Salzloeslichkeiten von LiBF4 und LiDFOB in EC/DEC (3/7) mit der Quarzmikrowaage (QCM) bestimmt. Weiterhin wurden

  13. Radioluminescence of synthetic quartz related to alkali ions

    Energy Technology Data Exchange (ETDEWEB)

    Martini, M., E-mail: m.martini@unimib.it [Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca, Via Cozzi 53, I-20125 Milano (Italy); INFN-Sezione di Milano Bicocca, Via Cozzi 53, I-20125 Milano (Italy); Fasoli, M. [Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca, Via Cozzi 53, I-20125 Milano (Italy); Galli, A. [Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca, Via Cozzi 53, I-20125 Milano (Italy); Istituto di Fotonica e Nanostrutture, IFN-CNR (Italy); Villa, I. [Dipartimento di Scienza dei Materiali, Universita degli Studi di Milano Bicocca, Via Cozzi 53, I-20125 Milano (Italy); Guibert, P. [IRAMAT-CRP2A (Institut de recherche sur les Archeomateriaux), UMR no. 5060, CNRS-Universite Bordeaux III, F-33607 Pessac (France)

    2012-04-15

    The radioluminescence (RL) of synthetic quartzes (GEMMA Quartz and Crystal Company) has been measured at room temperature. Some samples were treated by electrodiffusion ('sweeping') in order to change the concentrations of alkali ions, mainly Li{sup +} and Na{sup +}, which in quartz are known to be linked to Al ions, substitutional for Si ions. The RL emission spectra show evidence of a role of alkali ions in affecting some specific emissions. All the spectra could be analysed as composed of four bands in the blue and UV region. Specifically, the well known blue emission at around 470 nm was seen to be composed by two bands at 430 nm (2.86 eV) and at 485 nm (2.53 eV). Effects of irradiation, during the RL measurements, were clearly seen only in the 'Li swept in' sample, namely an increase in the 485 nm band intensity and a decrease in the 430 nm band one. The previously reported UV emission was detected at 355 nm (3.44 eV) in all the samples, being the most intense band in the 'swept out' sample. A further UV emission was detected at 315 nm (3.94 eV), more intense in untreated samples. Possible assignments of the detected emission bands are discussed in relation to the defects of quartz, specifically focusing on the Al centres that are most affected by sweeping procedures. - Highlights: Black-Right-Pointing-Pointer Contribution to the understanding of relationships between defects in quartz and luminescence emissions. Black-Right-Pointing-Pointer Role of charge compensators at substitutional Al sites in the optical properties of quartz. Black-Right-Pointing-Pointer Evidence of the double nature of the 'blue emission' (around 470 nm).

  14. Study of the α and β phases of quartz by neutron multiple diffraction

    International Nuclear Information System (INIS)

    Mazzocchi, V.L.

    1984-01-01

    Crystal structures of α and β phases of quartz are studied, employing neutron multiple diffraction as a method of analysis. Theoretical multiple diffraction patterns in a many-beam case were determined by a computer program which calculates intensities of beams as sums of Taylor's series expansions, retaining terms up to a order n. Experimental 'umweg' and transmitted beam patterns were obtained for the 00.1 primary reflection of α and β phases of quartz. To calculate α - quartz multiple diffraction intensities it was necessary to determine the Dauphine twinning fraction for the crystal after having passed by the β-phase. For the two models of β-quartz a better agreement between experimental and calculated integrated intensities was found for the disordered structure model based on split-half-oxigen positions. (Author) [pt

  15. Dew point fast measurement in organic vapor mixtures using quartz resonant sensor

    Science.gov (United States)

    Nie, Jing; Liu, Jia; Meng, Xiaofeng

    2017-01-01

    A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.

  16. Study of seed for synthetical quartz

    International Nuclear Information System (INIS)

    Suzuki, C.K.; Torikai, D.

    1988-01-01

    Natural quartz blocks for seed (synthetic quartz technology) were studied by using various characterization techniques, such as X-ray topography, optical micrography, inspectoscopy, polariscopy and conoscopy, and etching. One of the most commonly found defect is the electrical or Dauphine twin. In The present research, we have developed a methodology to obtain a highly perfect seed for the synthetic quartz industries. (author) [pt

  17. Radiation-Induced Changes in Quartz, A Mineral Analog of Nuclear Power Plant Concrete Aggregates.

    Science.gov (United States)

    Silva, Chinthaka M; Rosseel, Thomas M; Kirkegaard, Marie C

    2018-03-19

    Quartz single-crystal samples consisting of α-quartz crystal structure were neutron irradiated to fluences of 5 × 10 18 , 4 × 10 19 , and 2 × 10 20 n/cm 2 (E > 0.1 MeV) at two temperatures (52 and 95 °C). The changes in the α-quartz phase as a function of these two conditions (temperature and fluence) were studied using X-ray powder diffraction (XRD), Raman spectroscopy, and transmission electron microscopy (TEM), and the results acquired using these complementary techniques are presented in a single place for the first time. XRD studies showed that the lattice parameters of α-quartz increased with increasing neutron flux. The lattice growth was larger for the samples that were neutron irradiated at 52 °C than at 95 °C. Moreover, an amorphous content was determined in the quartz samples neutron irradiated at 4 × 10 19 n/cm 2 , with the greater amount being in the 52 °C irradiated sample. Complete amorphization of quartz was observed at a fluence of 2 × 10 20 n/cm 2 (E > 0.1 MeV) using XRD and confirmed by TEM characterization and Raman spectroscopic studies. The cause for α-quartz lattice expansion and sample amorphization was also explored using XRD and Raman spectroscopic studies.

  18. Toroidal helical quartz forming machine

    International Nuclear Information System (INIS)

    Hanks, K.W.; Cole, T.R.

    1977-01-01

    The Scyllac fusion experimental machine used 10 cm diameter smooth bore discharge tubes formed into a simple toroidal shape prior to 1974. At about that time, it was discovered that a discharge tube was required to follow the convoluted shape of the load coil. A machine was designed and built to form a fused quartz tube with a toroidal shape. The machine will accommodate quartz tubes from 5 cm to 20 cm diameter forming it into a 4 m toroidal radius with a 1 to 5 cm helical displacement. The machine will also generate a helical shape on a linear tube. Two sets of tubes with different helical radii and wavelengths have been successfully fabricated. The problems encountered with the design and fabrication of this machine are discussed

  19. Luminescence sensitivity changes in quartz

    CERN Document Server

    Wintle, A G

    1999-01-01

    In the luminescence dating of sedimentary or heated quartz, some heat treatment is usually applied to the sample immediately prior to the measurement of the optically stimulated luminescence. In this paper we report experiments on a 30,000-year-old sedimentary quartz, in which we use the luminescence response to a test dose to monitor the changes in sensitivity that are caused by holding the quartz at temperatures from 160 to 280 deg. C for times from 10 s to 22 h. For an optically bleached sample, the monitoring is by both optically stimulated luminescence and the 110 deg. C TL peak; both luminescence signals are shown to have the same sensitisation (i.e. activation energy) characteristics. For natural or laboratory irradiated samples only the 110 deg. C TL peak can be used; sensitivity increases of up to a factor of 1.3 and 3 are observed for the natural and laboratory irradiated aliquots, respectively. Up to four exponential components are used to deconvolve the sensitivity change data; the dominant compon...

  20. Nonsynchronous Noncommensurate Impedance Transformers

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Kim, K

    2012-01-01

    Nonsynchronous noncommensurate impedance transformers consist of a combination of two types of transmission lines: transmission lines with a characteristic impedance equal to the impedance of the source, and transmission lines with a characteristic impedance equal to the load. The practical...... advantage of such transformers is that they can be constructed using sections of transmission lines with a limited variety of characteristic impedances. These transformers also provide comparatively compact size in applications where a wide transformation ratio is required. This paper presents the data...... matrix approach and experimentally verified by synthesizing a 12-section nonsynchronous noncommensurate impedance transformer. The measured characteristics of the transformer are compared to the characteristics of a conventional tapered line transformer....

  1. Quartz glass behavior at ultraviolet spectrum region

    International Nuclear Information System (INIS)

    Braga, A.F.B.; Barbosa, L.C.; Evora, C.A.P.D.

    1990-01-01

    Melted quartz ingots were produced from raw materials of different sources. Behavior studies of these three different quartz glass were made at the eletromagnetic spectrum ultraviolet region. The atomic absorption spectroscopy was used as an analysis technique of the alkaline, transition and aluminum metal traces. It was found that the alkaline, transition and aluminum metals impurities present a great influence on the melted quartz spectral behavior at the ultraviolet region. It was stated that measurments at this spectrum region constitute an important characterization technique to natural quartz as well as melted quartz. (author) [pt

  2. Investigations on low temperature thermoluminescence centres in quartz

    International Nuclear Information System (INIS)

    Bernhardt, H.

    1984-01-01

    The present paper will help to understand the often investigated process of thermoluminescence of quartz which is of high complexity. A lot of traps exist in quartz crystals which compete with each other with respect to the trapping of charge carriers during the X-ray treatment. That is why a variety of processes takes place after X-irradiation at liquid nitrogen temperature (LNT) of quartz which complicate the phenomenology of low temperature thermoluminescence. This competition in the trapping process leads to the so-called 'sensibilization' or 'desensibilization' effects of thermoluminescence, respectively, which are described in this paper for the first time. This effect means the dependence of the LNT thermoluminescence intensity on a pre-irradiation dose applied at room temperature (RT). The influence of this pre-irradiation is understood assuming the saturation of competitive traps. This favours an enhanced trapping of charge carriers at LNT-(shallow) traps instead of the preferential trapping on the deep traps in the case of X-ray treatment of the as-grown crystal at LNT. To get the afore mentioned model we take into account not only thermoluminescence but also coloration, ir- and vuv-absorption measurements. (author)

  3. Impedance of a nanoantenna

    International Nuclear Information System (INIS)

    Greffet, Jean-Jacques; Laroche, Marine; Marquier, Francois

    2009-01-01

    We introduce a generalized definition of the impedance of a nanoantenna that can be applied to any system. We also introduce a definition of the impedance of a two level system. Using this framework, we establish a link between the electrical engineering and the quantum optics picture of light emission.

  4. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  5. Fracture flow due to hydrothermally induced quartz growth

    Science.gov (United States)

    Kling, Tobias; Schwarz, Jens-Oliver; Wendler, Frank; Enzmann, Frieder; Blum, Philipp

    2017-09-01

    Mineral precipitations are a common feature and limitation of initially open, permeable rock fractures by forming sealing structures or secondary roughness in open voids. Hence, the objective of this numerical study is the evaluation of hydraulic properties of fractures sealed by hydrothermally induced needle and compact quartz growth. Phase-field models of progressive syntaxial and idiomorphic quartz growth are implemented into a fluid flow simulation solving the Navier-Stokes equation. Flow simulations for both quartz types indicate an obvious correlation between changes in permeability, fracture properties (e.g. aperture, relative roughness and porosity) and crystal growth behavior, which also forms distinct flow paths. Thus, at lower sealing stages initial fracture permeability significantly drops down for the 'needle fracture' forming highly tortuous flow paths, while the 'compact fracture' records a considerably smaller loss. Fluid flow in both sealing fractures most widely is governed by a ;parallel plate;-like cubic law behavior. However, the 'needle fracture' also reveals flow characteristics of a porous media. A semi-theoretical equation is introduced that links geometrical (am) with hydraulically effective apertures (ah) and the relative fracture roughness. For this purpose, a geometry factor α is introduced being α = 2.5 for needle quartz and α = 1.0 for compact quartz growth. In contrast to most common ah-am-relationships this novel formulation not only reveals more precise predictions for the needle (RMSE = 1.5) and the compact fractures (RMSE = 3.2), but also exhibit a larger range of validity concerning the roughness of the 'needle' (σ/am = 0-2.4) and the 'compact fractures' (σ/am = 0-1.8).

  6. On luminescence lifetimes in quartz

    International Nuclear Information System (INIS)

    Chithambo, M.L.; Galloway, R.B.

    2000-01-01

    In this paper we present results of investigations concerning the time dependence of luminescence emission relative to the time of stimulation in quartz. Measurements of time-resolved spectra were performed on a new versatile pulsed light emitting diode system using 525 nm stimulation, an 11 μs duration pulse, a repetition rate of 11 kHz and a 64 μs dynamic range. Effects on luminescence lifetime resulting from sample treatments such as optical stimulation, irradiation, and preheating, are reported

  7. Characterization of growth sectors in synthetic quartz grown from cylindrical seeds parallel to [0001] direction

    Directory of Open Access Journals (Sweden)

    Pedro Luiz Guzzo

    2004-06-01

    Full Text Available In the present study, the morphology and the impurity distribution were investigated in growth sectors formed around the [0001] axis of synthetic quartz crystals. Plates containing cylindrical holes and cylindrical bars parallel to [0001] were prepared by ultrasonic machining and further used as seed-crystals. The hydrothermal growth of synthetic quartz was carried out in a commercial autoclave under NaOH solution during 50 days. The morphologies of crystals grown from cylindrical seeds were characterized by X-ray diffraction topography. For both types of crystals, +X- and X- growth sectors were distinctly observed. Infrared spectroscopy and ionizing radiation were adopted to reveal the distribution of point defects related to Si-Al substitution and OH-species. It was found a different distribution of Al-related centers in relation to the crystals grown from conventional Y-bar and Z-plate seeds.

  8. Magma reservoir dynamics at Toba caldera, Indonesia, recorded by oxygen isotope zoning in quartz.

    Science.gov (United States)

    Budd, David A; Troll, Valentin R; Deegan, Frances M; Jolis, Ester M; Smith, Victoria C; Whitehouse, Martin J; Harris, Chris; Freda, Carmela; Hilton, David R; Halldórsson, Sæmundur A; Bindeman, Ilya N

    2017-01-25

    Quartz is a common phase in high-silica igneous rocks and is resistant to post-eruptive alteration, thus offering a reliable record of magmatic processes in silicic magma systems. Here we employ the 75 ka Toba super-eruption as a case study to show that quartz can resolve late-stage temporal changes in magmatic δ 18 O values. Overall, Toba quartz crystals exhibit comparatively high δ 18 O values, up to 10.2‰, due to magma residence within, and assimilation of, local granite basement. However, some 40% of the analysed quartz crystals display a decrease in δ 18 O values in outermost growth zones compared to their cores, with values as low as 6.7‰ (maximum ∆ core-rim  = 1.8‰). These lower values are consistent with the limited zircon record available for Toba, and the crystallisation history of Toba quartz traces an influx of a low-δ 18 O component into the magma reservoir just prior to eruption. Here we argue that this late-stage low-δ 18 O component is derived from hydrothermally-altered roof material. Our study demonstrates that quartz isotope stratigraphy can resolve magmatic events that may remain undetected by whole-rock or zircon isotope studies, and that assimilation of altered roof material may represent a viable eruption trigger in large Toba-style magmatic systems.

  9. Radiation-Hard Quartz Cerenkov Calorimeters

    International Nuclear Information System (INIS)

    Akgun, U.; Onel, Y.

    2006-01-01

    New generation hadron colliders are going to reach unprecedented energies and radiation levels. Quartz has been identified as a radiation-hard material that can be used for Cerenkov calorimeters of the future experiments. We report from the radiation hardness tests performed on quartz fibers, as well as the characteristics of the quartz fiber and plate Cerenkov calorimeters that have been built, designed, and proposed for the CMS experiment

  10. Impedance and Collective Effects

    CERN Document Server

    Metral, E; Rumolo, R; Herr, W

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Chapter '4 Impedance and Collective Effects' with the content: 4 Impedance and Collective Effects Introduction 4.1 Space Charge 4.2 Wake Fields and Impedances 4.3 Coherent Instabilities 4.4 Landau Damping 4.5 Two-Stream Effects (Electron Cloud and Ions) 4.6 Beam-Beam Effects 4.7 Numerical Modelling

  11. Effect of pre-dose irradiation in the quartz and its use for archaelogical dating

    International Nuclear Information System (INIS)

    Yukimitu, K.

    1985-01-01

    The technique of pre-dose for dating ceramics, using the thermoluminescent properties of quartz is presented. The behavior of thermoluminescent (TL) sensitivity of the 110 0 C peak of Brazilian quartz, in its geologic state, submitted to thermal treatments from 600 to 900 0 C, is studied. The samples were tritured for separating the quartz crystals from clay. The quartz grains were submitted to leaching with chloric acid solution followed by leaching with running water. The samples were irradiated in laboratory, with gamma radiation using Co-60 and Cs-137 sources, for calibration. A sensitivity enhancement rate of 2% per rad was observed for samples annealed at 900 0 C, was observed. (M.C.K.) [pt

  12. EPR investigation into the structure of boron-containing quartz glasses

    International Nuclear Information System (INIS)

    Amosov, A.V.; Bushmarin, D.B.; Prokhorova, T.I.; Yudin, D.M.

    1975-01-01

    Certain properties of boron-containing quartz glasses and the nature of occurrence of boron in the glass lattice are studied as functions of the method of alloying. The formation of three types of borate structural nodes (BO 4 , BO 3 and BO 4 -BO 3 ) in the lattice of quartz glasses is established. Alloying by boron oxide up to 3% (weight) increases the crystallization stability of quartz glasses, lowers down tsub(g) from 1220 to 950 deg C and does not affect the coefficient of thermal expansion. Low symmetry of borate structural nodes, following from the analysis of EPR spectra, confirms the literature data concerning the low symmetry of glass-forming polyhedrons in a quartz glass

  13. Imperfections study of the smoky quartz from Bahia by X-ray diffraction

    International Nuclear Information System (INIS)

    D'Aguiar Neto, M.M.F.

    1974-01-01

    X-ray diffraction techniques were used to study the type of point defects in Smoky quartz from Itambe and Vitoria da Conquista in Bahia. The power method, using the Seemann Bohlin camara (back refletion), was utilized in the analysis of the policrystals, while the monocrystals were studied by means of the precession camara. The positions occupied by the defects in the crystal net were calculated. The results show that while the defects of substitutional impurities predominate in the quartz from Itambe, in the quartz from Vitoria da Conquista the substitutional defects exist in comparable proportions that the interstital ones. Isochronous annealing curves, for both type of smoky quartz indicate an increase in the net parameter to temperature values above the annealing temperatures. Was formulated the hypothesis that providing a thermal energy greater than that of annealing is used, new interstitial defects would be created as a result of a thermic diffusion mechanism. (C.D.G.) [pt

  14. Plasma-assisted quartz-to-quartz direct bonding for the fabrication of a multilayered quartz template for nanoimprint lithography

    International Nuclear Information System (INIS)

    Lee, Jihye; Ali, Altun; Kim, Ki-don; Choi, Dae-guen; Choi, Jun-Hyuk; Jeong, Jun-ho; Kim, Jae-Hyun

    2010-01-01

    In this paper, a low-temperature plasma-assisted process is developed to realize a uniform, ultraviolet (UV) transparent and chemically inert quartz-to-quartz direct bonding. Two sets of pretests are performed in order to understand how the bond surface energy changes with the plasma exposure time and the wet etching of quartz, respectively. The developed technique is used to fabricate a multilayered quartz template for UV nanoimprint lithography (UV-NIL). The multilayered quartz template is fabricated by bonding a square piece of a standard quartz wafer, which is about 625 µm in thickness, to a wet-etched 6.35 mm thick quartz photomask plate. A fabricated multilayered template is loaded to the commercial UV-NIL tool Imprio(TM) 100, and NIL was performed successfully. The developed direct bonding technique makes it possible for standard quartz wafers, which are compatible with high-resolution semiconductor fabrication processes, to be utilized as the templates in commercial UV-NIL machines with enhanced mechanical stability.

  15. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  16. Impedance and component heating

    CERN Document Server

    Métral, E; Mounet, N; Pieloni, T; Salvant, B

    2015-01-01

    The impedance is a complex function of frequency, which represents, for the plane under consideration (longitudinal, horizontal or vertical), the force integrated over the length of an element, from a “source” to a “test” wave, normalized by their charges. In general, the impedance in a given plane is a nonlinear function of the test and source transverse coordinates, but it is most of the time sufficient to consider only the first few linear terms. Impedances can influence the motion of trailing particles, in the longitudinal and in one or both transverse directions, leading to energy loss, beam instabilities, or producing undesirable secondary effects such as excessive heating of sensitive components at or near the chamber wall, called beam-induced RF heating. The LHC performance limitations linked to impedances encountered during the 2010-2012 run are reviewed and the currently expected situation during the HL-LHC era is discussed.

  17. Development of Quartz Fiber Calorimetry

    CERN Multimedia

    2002-01-01

    % RD40 \\\\ \\\\ Very Forward Calorimeters (VFCs) in LHC detectors should cover the pseudorapidity range from $\\eta$~=~2.5 to at least $\\eta$~=~5 in order to compute missing transverse energy and for jet tagging. Operation at such high rapidity requires the use of a calorimetry technique that is very radiation resistant, fast and insensitive to radioactivity (especially to neutrons). This can be accomplished through the Quartz-Calorimeter~(Q-Cal) concept of embedding silica core fibers, that resist to the Gigarad radiation level, into an absorber. In this calorimeter the shower particles produce light through the Cherenkov effect generating a signal less than 10~ns in duration. Unique to this new technology the visible energy of hadronic showers has a transverse dimension nearly an order of magnitude smaller than that in conventional calorimeters, enabling precise spatial resolution, sharper isolation cuts and better jet recognition against the minimum bias events background. Last but not least, most radioactive ...

  18. The LEP impedance model

    Energy Technology Data Exchange (ETDEWEB)

    Zotter, B [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    This report describes a number of measurements and computations of the impedance of the Large Electron Positron collider LEP at CERN. The work has been performed over several years, together with D. Brandt, K. Cornelis, A. Hofmann, G. Sabbi and many others. The agreement between measurements of single bunch instabilities on the machine and computer simulations is in general excellent and gives confidence in the impedance model used. (author)

  19. Characterization of hydrothermal green quartz produced by gamma radiation

    Energy Technology Data Exchange (ETDEWEB)

    Enokihara, Cyro T.; Rela, Paulo R., E-mail: cteiti@ipen.br, E-mail: prela06@yahoo.com.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Schultz-Güttler, Rainer A., E-mail: rainersgut@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Geociencias

    2015-07-01

    A specific variety of quartz showing a green color in nature or induced artificially by radiation gamma ({sup 60}Co) is quite rare. Only two occurrences are known today, where this type of quartz can be found: Canada, at the Thunder Bay Amethyst Mine, Ontario and Brazil, at widely scattered geode occurrences along a 600 km stretch from Quarai at Brazils southern most tip to Uberlandia in Minas Gerais. These two occurrences have been formed by strong hydrothermal activities.That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects (twinning, small angle tilting, mosaic growth, striations) and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. In the present work the material analyzed is from hydrothermal regimes found in intrusions of basaltic rocks located in the Rio Grande do Sul state. To characterize these materials, colored green by gamma rays, analyses by ICP, electron microscopy, water loss techniques and UV-VIS or NIR-FTIR spectroscopic measurements have been made. Silanol complexes are formed, which by radiation due to gamma rays form the color center NBOHC (Non-bonding Oxygen Hole Center), showing absorption between 590 to 620 nm, responsible for the green color. The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). There is no correlation between water content and cations as in other color varieties. (author)

  20. Quartz gauge response in ion radiation

    International Nuclear Information System (INIS)

    Taylor, P.E.; Gilbert, P.H.; Kernthaler, C.; Anderson, M.U.

    1995-01-01

    This paper describes recent work to make high quality quartz gauge (temporal and spatial) shock wave measurements in a pulsed ion beam environment. Intense ion beam radiation, nominally 1 MeV protons, was deposited into material samples instrumented with shunted quartz gauges adjacent to the ion deposition zone. Fluence levels were chosen to excite three fundamentally different material response modes (1) strong vapor, (2) combined vapor and melt phase and (3) thermoelastic material response. A unique quartz gauge design was utilized that employed printed circuit board (PCB) technology to facilitate electrical shielding, ruggedness, and fabrication at sign e meeting the essential one dimensional requirements of the characterized Sandia shunted quartz gauge. Shock loading and unloading experiments were conducted to evaluate the piezoelectric response of the coupled quartz gauge/PCB transducer. High fidelity shock wave profiles were recorded at the three ion fluence levels providing dynamic material response data for vapor, melt and solid material phases

  1. Crystallinity study of a faceted Brazilian quartz by X-rays topography

    International Nuclear Information System (INIS)

    Suzuki, C.K.; Farias, C.R.L.

    1986-01-01

    A characterization study of crystalline perfection along the Z-direction (from the base to the top) of a single crystal of natural quartz was conducted. A gradual and very significanty change of crystalline perfection with the transparency was revealed by X-ray topography and goniometric observation in samples cut along perpendicular to the Z-direction. (L.J.) [pt

  2. Orientation of quartz nanocrystallites in the silicon lattice

    International Nuclear Information System (INIS)

    Kalanov, M.U.; Ibragimova, E.M.; Khamraeva, R.N.; Rustamova, V.M.; Ummatov, Kh.D.

    2006-01-01

    Full text: Basing on the study of medium angle diffuse X-ray scattering from silicon single crystals, it was supposed to be due to rod like oxygen precipitates. It was shown by us later, that depending on the growth conditions, as-grown silicon single crystals contain quartz crystal inclusions at an amount of 0.3 / 0.5 wt. % . Since it has not been done before, the aim of this work was to study the shape and orientation of quartz inclusions relative to a chosen axis of the silicon crystal lattice. We studied p-Si single crystals of one crucible origin with the specific resistance ρ 0 ≅ 1/10 Ohm· cm with different cut surfaces parallel to the crystal planes (100), (110) and (111). All the samples were cut and polished in the bar form with the sizes of 20x12x1.5 mm 3 . The dislocation density was N D ≅ 10 1 /10 3 cm -2 , the concentrations of oxygen and boron were N O ≅ 2/ 4 x10 17 cm -3 and N B ≅ 3· 10 1 5 c m -3 . Structure was analyzed at the set-up DRON-3M ( λ Cu K∝ = 0.1542 nm) at the room temperature in the angle range of angles 2Θ = 10/70 deg. The diffraction spectrum of the sample cut in (111) includes 5 selective reflections and the only diffuse one at 2Θ≅ 20 deg (d/n≅ 0.3136 nm), having a large width 0.1032 rad, which is due to presence of amorphous SiO x precipitate in the surface layer of silicon single crystal. The dominative selective line with d/n≅ 0.3136 nm at 2Θ≅ 28.5 deg belongs to reflection from (111) planes of the silicon lattice and the second less intensive one comes from the same planes with Cu K β radiation. Another selective reflection of a medium intensity at 2Θ≅ 59 deg with d/n≅ 0.1568 nm is its second order (222) and forbidden by the weakening laws. The rest narrow but weak lines with d/n≅ 0.3345 nm at 2Θ≅ 26.6 deg and 0.2468 nm at≅36.6 deg correspond to the diffraction reflections (101) and (110) from the crystal quartz lattice SiO 2 . It means that they are caused by optimally oriented quartz

  3. Impeded Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, Joachim; Liu, Jia [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Slatyer, Tracy R. [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States); Wang, Xiao-Ping [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Xue, Wei [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States)

    2016-12-12

    We consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario “Impeded Dark Matter”. We demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.

  4. Impeded Dark Matter

    International Nuclear Information System (INIS)

    Kopp, Joachim; Liu, Jia; Slatyer, Tracy R.; Wang, Xiao-Ping; Xue, Wei

    2016-01-01

    We consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario “Impeded Dark Matter”. We demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.

  5. Dating quartz: Ar/Ar analyses of coexisting muscovite and fluid inclusion - rich quartz from paleocene amorphic aureole

    International Nuclear Information System (INIS)

    Matthews, S.J.; Perez de Arce, C.; Cornejo, P.; Cuitino, L; Klein, J

    2001-01-01

    We present Ar/Ar total fusion and step-heating data for coexisting muscovite and white quartz from the metamorphic aureole of the Lower Paleocene La Copiapina Pluton, 6 km south of Inca de Oro, III Region, Chile. The pluton intrudes the upper clastic sedimentary member of the Punta del Cobre Group (Upper Jurassic - Lower Cretaceous) and the calcareous sedimentary rocks of the Chanarcillo Group (Neocomian), and comprises fine to coarse grained pyroxene-hornblende-biotite quartz diorites and monzodiorites. Its emplacement was controlled on its north-western side by a subvertical NE-trending fault, along which were developed vertically banded skarns (skarn mylonite), suggesting syntectonic intrusion. Biotite K-Ar ages for the pluton fall in the range 61-63 Ma, relating it to a latest Cretaceous to Lowest Paleocene syn-compressional intrusive belt which is present in the area (Matthews and Cornejo, 2000). A metamorphic / metasomatic aureole is developed within the sandstones of the Punta del Cobre Group, on the extreme northern limit of the pluton. In this area, the sedimentary rocks have been replaced by quartz-sericite and quartz-muscovite assemblages, with minor hematite and tourmaline, and late supergene kaolinite and pyrophyllite. A coarse muscovite-quartz-tourmaline-hematite assemblage is developed in and around older (early Upper Cretaceous) andesitic dykes, in the form of replacement / fracture fill veins and replacement zones. Further from the contact with the pluton, fine-grained quartz-sericite rock with coarser muscovite-rich replacement veins represents the dominant lithology. Quartz in the coarse replacement rock is very rich in fluid inclusions. Primary inclusions are mainly of two coexisting types; bi-phase (liquid and gas bubble) and tri-phase (liquid, gas bubble and halite crystal), indicating that the quartz formed in the presence of a boiling fluid. Some inclusions also contain sylvite and occasional hematite daughter crystals. Secondary inclusions

  6. Silver-compensated germanium center in α-quartz

    International Nuclear Information System (INIS)

    Laman, F.C.; Weil, J.A.

    1977-01-01

    A synthetic germanium-doped crystal of α-quartz was subjected to an electro-diffusion process (ca. 600 V/cm, 625 0 K), in which Ag + ions were introduced along the crystal's optic axis (c). A 9800 MHz electron paramagnetic resonance spectrum at room temperature, taken after room temperature X-irradiation, revealed the presence of a silver-compensated germanium center Asub(Ge-Ag) with large, almost isotropic 107 Ag and 109 Ag hyperfine splittings. Measurement of the spin-Hamiltonian discloses that a suitable model for the observed center utilizes germanium, substituted for silicon, with the accompanying silver interstitial in a nearby c-axis channel, and with electronic structure in which an appreciable admixture Ge 4+ - Ag 0 to Ge 3+ - Ag + exists. Estimates of the unpaired electron orbital are presented. (author)

  7. Mineralogy, morphology, and textural relationships in coatings on quartz grains in sediments in a quartz-sand aquifer

    Science.gov (United States)

    Zhang, Shouliang; Kent, Douglas B.; Elbert, David C.; Shi, Zhi; Davis, James A.; Veblen, David R.

    2011-01-01

    Mineralogical studies of coatings on quartz grains and bulk sediments from an aquifer on Western Cape Cod, Massachusetts, USA were carried out using a variety of transmission electron microscopy (TEM) techniques. Previous studies demonstrated that coatings on quartz grains control the adsorption properties of these sediments. Samples for TEM characterization were made by a gentle mechanical grinding method and focused ion beam (FIB) milling. The former method can make abundant electron-transparent coating assemblages for comprehensive and quantitative X-ray analysis and the latter technique protects the coating texture from being destroyed. Characterization of the samples from both a pristine area and an area heavily impacted by wastewater discharge shows similar coating textures and chemical compositions. Major constituents of the coating include Al-substituted goethite and illite/chlorite clays. Goethite is aggregated into well-crystallized domains through oriented attachment resulting in increased porosity. Illite/chlorite clays with various chemical compositions were observed to be mixed with goethite aggregates and aligned sub-parallel to the associated quartz surface. The uniform spatial distribution of wastewater-derived phosphorus throughout the coating from the wastewater-contaminated site suggests that all of the coating constituents, including those adjacent to the quartz surface, are accessible to groundwater solutes. Both TEM characterization and chemical extraction results indicate there is a significantly greater amount of amorphous iron oxide in samples from wastewater discharge area compared to those from the pristine region, which might reflect the impact of redox cycling of iron under the wastewater-discharge area. Coating compositions are consistent with the moderate metal and oxy-metalloid adsorption capacities, low but significant cation exchange capacities, and control of iron(III) solubility by goethite observed in reactive transport

  8. Geology and geochemistry of giant quartz veins from the ...

    Indian Academy of Sciences (India)

    Numerous younger thin quartz veins with somewhat similar orientation cut across the giant quartz .... Angular fragments of quartz are set in ... places along grain boundaries. ... Oxide values are in wt%, and trace element concentrations are.

  9. Impedance of accelerator components

    International Nuclear Information System (INIS)

    Corlett, J.N.

    1996-05-01

    As demands for high luminosity and low emittance particle beams increase, an understanding of the electromagnetic interaction of these beams with their vacuum chamber environment becomes more important in order to maintain the quality of the beam. This interaction is described in terms of the wake field in time domain, and the beam impedance in frequency domain. These concepts are introduced, and related quantities such as the loss factor are presented. The broadband Q = 1 resonator impedance model is discussed. Perturbation and coaxial wire methods of measurement of real components are reviewed

  10. Superconducting active impedance converter

    International Nuclear Information System (INIS)

    Ginley, D.S.; Hietala, V.M.; Martens, J.S.

    1993-01-01

    A transimpedance amplifier for use with high temperature superconducting, other superconducting, and conventional semiconductors allows for appropriate signal amplification and impedance matching to processing electronics. The amplifier incorporates the superconducting flux flow transistor into a differential amplifier configuration which allows for operation over a wide temperature range, and is characterized by high gain, relatively low noise, and response times less than 200 picoseconds over at least a 10-80 K. temperature range. The invention is particularly useful when a signal derived from either far-IR focal plane detectors or from Josephson junctions is to be processed by higher signal/higher impedance electronics, such as conventional semiconductor technology. 12 figures

  11. Fission track dating of authigenic quartz in red weathering crusts of carbonate rocks in Guizhou province

    International Nuclear Information System (INIS)

    Liu Xiuming; Wang Shijie; Zhang Feng

    2004-01-01

    The Cenozoic evolution history of Guizhou Province, which is located on the southeastern flank of the Qinghai-Tibet Plateau, is unclear because of the lack of sedimentation records. The red weathering crusts widespread on the Yunnan-Guizhou Plateau may bear critical information about their evolution history. This work firstly determined the ages of four red weathering crusts in eastern, central and northern Guizhou. The material used in fission track dating is well-crystallized quartz occurring in many in-situ weathering crusts of carbonate rocks. The results showed that the fission track ages of quartz vary over a wide range from 1 Ma to 25 Ma in the four profiles, significantly younger than the ages of Triassic and Cambrian parent rocks. In combination with the regionally geological evolution history during the period from 25 Ma to 1 Ma, the ages of quartz can exclude the possibility that the origin of quartz has nothing to do with primary clastic minerals in parent rocks, authigenesis during diagenesis and hydrothermal precipitation or replacement by volcanic activities. It is deduced that the well-crystallized quartz was precipitated from Si-rich weathering fluids during weathering processes of carbonate rocks. The recorded ages of quartz from the four profiles are consistent with the episodes of planation surfaces on the Qinghai-Tibet Plateau, the stages of red soil in the tropics of South China, the tectonically stable periods in Guizhou, and the ages of weathering in other parts of the world during the Cenozoic era. That is to say, the ages of authigenic quartz dated by the fission track method are well feasible and credible. (authors)

  12. Oxygen isotopic ratios in quartz as an indicator of provenance of dust

    International Nuclear Information System (INIS)

    Jackson, M.L.

    1977-01-01

    Quartz was isolated in the long range aerosol size range (fine silt, 1-10 μm in diameter) from atmospheric aerosols, wind-erosive soils, soil silts, shales, and Pacific pelagic sediments of the Northern and Southern Hemispheres, to trace their provenance or origin, as part of a study of dust mineral sequestering of 137 Cs and other products of nuclear fission. The oxygen isotopic ratio ( 18 O/ 16 O) was determined by mass spectrometry. The provenance has been established for this fine silt fraction which reflects the relative proportion of two classes of quartz source: (a) weathering of igneous and metamorphic rocks (high temperature origin and low 18 O/ 16 O ratio) and (b) of quartz crystallized in cherts and overgrowths (low temperature origin and high 18 O/ 16 O ratio). This quartz mixing ratio is a basic model or paradigm. Analyses of present day atmospheric aerosols and eolian-derived soils, Pacific pelagic sediments, and now-raised Phanerozoic marine sediments show that the Northern and Southern Hemispheres have separate large-scale reservoirs of the fine grain sizes that contribute to aerosol dusts. These can be identified by distinctive values of 18 O/ 16 O ratios of the quartz therein. The difference in quartz delta 18 O value in parts per thousand per ml ( 0 / 00 of about 12 +- 2 0 / 00 in Southern Hemisphere mixed detrital sediments and about 19 +- 2 0 / 00 in those of the Northern Hemisphere (for constant size, the 1-10 μm size fraction) results from the presence of a considerably larger proportion of quartz having low-temperature origin and higher delta 18 O values (chert, silica overgrowths, etc.) in the Northern Hemisphere reservoirs. The early paleoclimatic and paleogeochemical differences remain the control of the North-South Hemisphere difference in delta 18 O values in long-range aerosol sized quartz

  13. Quartz-Enhanced Photoacoustic Spectroscopy: A Review

    Science.gov (United States)

    Patimisco, Pietro; Scamarcio, Gaetano; Tittel, Frank K.; Spagnolo, Vincenzo

    2014-01-01

    A detailed review on the development of quartz-enhanced photoacoustic sensors (QEPAS) for the sensitive and selective quantification of molecular trace gas species with resolved spectroscopic features is reported. The basis of the QEPAS technique, the technology available to support this field in terms of key components, such as light sources and quartz-tuning forks and the recent developments in detection methods and performance limitations will be discussed. Furthermore, different experimental QEPAS methods such as: on-beam and off-beam QEPAS, quartz-enhanced evanescent wave photoacoustic detection, modulation-cancellation approach and mid-IR single mode fiber-coupled sensor systems will be reviewed and analysed. A QEPAS sensor operating in the THz range, employing a custom-made quartz-tuning fork and a THz quantum cascade laser will be also described. Finally, we evaluated data reported during the past decade and draw relevant and useful conclusions from this analysis. PMID:24686729

  14. Quartz-Enhanced Photoacoustic Spectroscopy: A Review

    Directory of Open Access Journals (Sweden)

    Pietro Patimisco

    2014-03-01

    Full Text Available A detailed review on the development of quartz-enhanced photoacoustic sensors (QEPAS for the sensitive and selective quantification of molecular trace gas species with resolved spectroscopic features is reported. The basis of the QEPAS technique, the technology available to support this field in terms of key components, such as light sources and quartz-tuning forks and the recent developments in detection methods and performance limitations will be discussed. Furthermore, different experimental QEPAS methods such as: on-beam and off-beam QEPAS, quartz-enhanced evanescent wave photoacoustic detection, modulation-cancellation approach and mid-IR single mode fiber-coupled sensor systems will be reviewed and analysed. A QEPAS sensor operating in the THz range, employing a custom-made quartz-tuning fork and a THz quantum cascade laser will be also described. Finally, we evaluated data reported during the past decade and draw relevant and useful conclusions from this analysis.

  15. Fabrication of quartz microcylinders by laser interference lithography for angular optical tweezers

    Science.gov (United States)

    Santybayeva, Zhanna; Meghit, Afaf; Desgarceaux, Rudy; Teissier, Roland; Pichot, Frederic; de Marin, Charles; Charlot, Benoit; Pedaci, Francesco

    2016-07-01

    The use of optical tweezers (OTs) and spin angular momentum transfer to birefringent particles allows new mechanical measurements in systems where torque and rotation are relevant parameters at the single-molecule level. There is a growing interest in developing simple, fast, and inexpensive protocols to produce a large number of submicron scale cylinders of quartz, a positive uniaxial birefringent crystal, to be employed for such angular measurements in OTs. Here, we show that laser interference lithography, a method well known for its simplicity, fulfills these requirements and produces quartz cylindrical particles that we successfully use to apply and measure optical torque in the piconewton nm range in an optical torque wrench.

  16. Fluid Inclusion Analysis of other Host Minerals besides Quartz: Application to Granite-Related Quartz-Topaz Veins and Garnet Skarns in Porphyry Copper-Gold Ore Systems

    OpenAIRE

    Schlöglova, Katerina

    2018-01-01

    Fluid inclusions are the only available samples of paleo-fluids responsible for crystallization of hydrothermal minerals including ore phases. Analysis of fluid inclusions implicitly assumes that the inclusions have preserved their chemical composition since the time of their entrapment. There is, however, an increasing evidence from experimental work and analytical studies of natural samples showing that inclusions hosted in quartz – a ubiquitous host in many ore-forming systems – can experi...

  17. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.; Kundhikanjana, W.; Peng, H.; Cui, Y.; Kelly, M. A.; Shen, Z. X.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately

  18. SSC kicker impedances

    International Nuclear Information System (INIS)

    Colton, E.P.; Wang, T.F.

    1985-01-01

    The longitudinal and transverse complex impedances Z/sub l//n and Z/sub t/, respectively, have been calculated for both the SSC injection and abort kickers. The calculations assumed that no attempt was made to shield the beam from the kickers. We took the injection and abort kickers to be as specified. The injection kickers were ferrite with a single-turn design, and the abort kickers were of a ''window-frame design'' with tape wound cores

  19. Design and fabrication of an AT-cut quartz phononic Lamb wave resonator

    International Nuclear Information System (INIS)

    Hung, Chia-Hao; Liu, Ting-Wei; Wu, Tsung-Tsong; Wang, Wei-Shan; Esashi, Masayoshi; Lin, Yu-Ching; Sun, Jia-Hong; Chen, Yung-Yu

    2013-01-01

    This paper presents results on the design and fabrication of an AT-cut quartz Lamb wave resonator with phononic crystal (PC) reflective gratings. The deep reactive ion etching process with a laboratory-made etcher was utilized to fabricate PC structures of the AT-cut quartz Lamb wave resonator. The finite element method was adopted to calculate the PC band structure, effective reflective distance from the PC boundary and further the resonant modes and admittance of the phononic Lamb wave resonant cavity. Through the comparison studies between the experimental and simulated results, a design process for the AT-cut quartz phononic Lamb wave resonator was proposed. It is noted that by using the phononic reflectors, the size of the Lamb wave resonator can be reduced significantly. (paper)

  20. Determination of the hexagonal network parameters of the quartz β using neutron multiple diffraction

    International Nuclear Information System (INIS)

    Campos, L.C.; Parente, C.B.R.; Mazzocchi, V.L.; Helene, O.

    2000-01-01

    In this work, neutron multiple diffraction is employed for the determination of the parameters a and c of the β-quartz hexagonal cell. This crystalline phase of silica (SiO 2 ) occurs in temperatures between ca. 846 and 1143 K. A β-quartz neutron multiple diffraction pattern has been used in the determinations. This pattern was obtained with a natural quartz single crystal heated to 1003 K. During the indexing of the pattern it was verified that most of the pairs of secondary reflections, which are responsible for the formation of peaks, could be classified as 'good for the determination of a' or 'good for the determination of c'. With this classification, it became possible to employ an iterative method for the determination of both parameters. After 8 cycles of iteration the values found for the parameters were a = 4.9964 +- 0.0018 and c = 5.46268 +- 0.00052 A. (author)

  1. A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Galigekere, Veda Prakash

    2016-01-01

    A novel A-source impedance network is proposed in this letter. The A-source impedance network uses an autotransformer for realizing converters for any application that demand a very high dc voltage gain. The network utilizes a minimal turns ratio compared to other Magnetically Coupled Impedance S...

  2. Impedance analysis of subwoofer systems

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    The electrical impedance of four low-frequency loudspeaker systems is analyzed. The expression for this impedance is obtained directly from the acoustical analogous circuit. Formulas are derived for calculating the small-signal parameters from the frequencies of impedance minima and maxima of two

  3. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  4. Additive manufacturing of transparent fused quartz

    Science.gov (United States)

    Luo, Junjie; Hostetler, John M.; Gilbert, Luke; Goldstein, Jonathan T.; Urbas, Augustine M.; Bristow, Douglas A.; Landers, Robert G.; Kinzel, Edward C.

    2018-04-01

    This paper investigates a filament-fed process for additive manufacturing (AM) of fused quartz. Glasses such as fused quartz have significant scientific and engineering applications, which include optics, communications, electronics, and hermetic seals. AM has several attractive benefits such as increased design freedom, faster prototyping, and lower processing costs for small production volumes. However, current research into glass AM has focused primarily on nonoptical applications. Fused quartz is studied here because of its desirability for use in high-quality optics due to its high transmissivity and thermal stability. Fused quartz filaments are fed into a CO2 laser-generated molten region, smoothly depositing material onto the workpiece. Spectroscopy and pyrometry are used to measure the thermal radiation incandescently emitted from the molten region. The effects of the laser power and scan speed are determined by measuring the morphology of single tracks. Thin walls are printed to study the effects of layer-to-layer height. This information is used to deposit solid pieces including a cylindrical-convex shape capable of focusing visible light. The transmittance and index homogeneity of the printed fused quartz are measured. These results show that the filament-fed process has the potential to print transmissive optics.

  5. Observations involving broadband impedance modelling

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J S [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    Results for single- and multi-bunch instabilities can be significantly affected by the precise model that is used for the broadband impedance. This paper discusses three aspects of broadband impedance modelling. The first is an observation of the effect that a seemingly minor change in an impedance model has on the single-bunch mode coupling threshold. The second is a successful attempt to construct a model for the high-frequency tails of an r.f. cavity. The last is a discussion of requirements for the mathematical form of an impedance which follow from the general properties of impedances. (author)

  6. The Shahewan rapakivi-textured granite – quartz monzonite pluton, Qinling orogen, central China: mineral composition and petrogenetic significance

    Directory of Open Access Journals (Sweden)

    Xiaoxia Wang

    2002-01-01

    Full Text Available The Mesozoic Shahewan pluton consists of four texturally different types of biotite-hornblende quartz monzonite. In the porphyritic types alkali feldspar occurs as euhedral or ovoidal megacrysts that are often mantled by one or more plagioclase shells, and as smaller grains in the groundmass. Quartz, plagioclase (An20–28, biotite, and hornblende occur as inclusions in the alkali feldspar megacrystsand, more abundantly, in the groundmass. Euhedral quartz crystals in the groundmass are not as common and well developed as in typical rapakivi granite. Compared to typical rapakivi granites, the mafic minerals (biotite and hornblende are rich in Mg and poor in Fe, and the whole rock is low in Si, K, F, Ga, Zr, LREE, Fe/Mg, and K/Na. The rocks of the Shahewan pluton are thus regarded as rapakivi-textured quartz monzonites and granites but not true rapakivi granites.

  7. Radiation resistivity of quartz core fiber, 3

    International Nuclear Information System (INIS)

    Gozen, Toshikazu; Suzuki, Toshiya; Hayashi, Tokuji; Tanaka, Hiroyuki; Okamoto, Shinichi.

    1985-01-01

    Radiation resistance characteristics were evaluated for a multi-mode quartz core fiber in low temperature region together with photobleaching effect depending on the incident light power and dependency on the wavelength of measuring rays. This report describes the results of the abovementioned items and the next step study of trial manufacturing of a pure-quartz single-mode fiber for the employment of longer wavelength rays and greater capacity in light transmission communication system. Quartz core fiber specimens were irradiated by 60 Co γ-ray source at -55 deg C to 80 deg C in a constant temperature bath and light transmission loss was determined under irradiation conditions. Low temperature characteristics were superior in an MRT (modified rod-in tube) pure quartz fiber prepared by the plasma method as compared to VAD quartz and Ge-GI fibers. The MRT fiber showed better quality than the Ge-GI fiber also in the photobleaching effect examination. As for the wavelength dependency, light transmission loss of the MRT fiber was less than that of the Ge-GI fiber. The MRT fiber also showed a superior quality in the wide range of irradiation temperatures. Based on the above-mentioned understandings, a pure-quartz single-mode fiber of both BF 3 -doped and F-doped cladding types were developed for longer wavelengths uses. The fibers could attain low light transmission loss of less than 1.0 dB/km at 1.30 μm of wavelength. At the standpoint of radiation resistivity, the BF 3 -doped fiber was found superior. (Takagi, S.)

  8. LIA longitudinal coupling impedance

    International Nuclear Information System (INIS)

    Faltens, A.

    1980-01-01

    The beam generated fields enter into the problems of waveform generation and longitudinal stability. In the former, provision must be made for the longitudinally defocusing forces due to the space charge and the beam loading effects on the accelerating voltage due to the current of a presumably known bunch. In the latter, the concern is for the growth of unintentional perturbations to unacceptably large values through the interaction of the charge and current fluctuations with the rest of the beam and the surrounding structures. These beam generated electric fields may be related to the beam current through a coupling impedance

  9. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  10. Estimating Quartz Reserves Using Compositional Kriging

    Directory of Open Access Journals (Sweden)

    J. Taboada

    2013-01-01

    Full Text Available The aim of this study was to determine spatial distribution and volume of four commercial quartz grades, namely, silicon metal, ferrosilicon, aggregate, and kaolin (depending on content in impurities in a quartz seam. The chemical and mineralogical composition of the reserves in the seam were determined from samples collected from outcrops, blasting operations, and exploratory drilling, and compositional kriging was used to calculate the volume and distribution of the reserves. A more accurate knowledge of the deposit ensures better mine planning, leading to higher profitability and an improved relationship with the environment.

  11. Electrical impedance tomography

    Science.gov (United States)

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  12. Microwave Impedance Measurement for Nanoelectronics

    Directory of Open Access Journals (Sweden)

    M. Randus

    2011-04-01

    Full Text Available The rapid progress in nanoelectronics showed an urgent need for microwave measurement of impedances extremely different from the 50Ω reference impedance of measurement instruments. In commonly used methods input impedance or admittance of a device under test (DUT is derived from measured value of its reflection coefficient causing serious accuracy problems for very high and very low impedances due to insufficient sensitivity of the reflection coefficient to impedance of the DUT. This paper brings theoretical description and experimental verification of a method developed especially for measurement of extreme impedances. The method can significantly improve measurement sensitivity and reduce errors caused by the VNA. It is based on subtraction (or addition of a reference reflection coefficient and the reflection coefficient of the DUT by a passive network, amplifying the resulting signal by an amplifier and measuring the amplified signal as a transmission coefficient by a common vector network analyzer (VNA. A suitable calibration technique is also presented.

  13. NOTE: Impedance magnetocardiogram

    Science.gov (United States)

    Kandori, Akihiko; Miyashita, Tsuyoshi; Suzuki, Daisuke; Yokosawa, Koichi; Tsukada, Keiji

    2001-02-01

    We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart - the so-called magnetocardiogram (MCG) - can be simultaneously detected by using this system. Because the mechanical and electrical functions in the heart can be monitored by non-invasive and non-contact measurements, it is easy to observe the cardiovascular functions from an accurate sensor position. This system uses a technique to demodulate induced current in a subject. A flux-locked circuit of a superconducting quantum interference device has a wide frequency range (above 1 MHz) because a constant current (40 kHz) is fed through the subject. It is shown for the first time that the system could measure IMCG signals at the same time as MCG signals.

  14. Brittle to Semibrittle Transition in Quartz Sandstone: Energetics

    Science.gov (United States)

    Kanaya, Taka; Hirth, Greg

    2018-01-01

    Triaxial compression experiments were conducted on a quartz sandstone at effective pressures up to 175 MPa and temperatures up to 900°C. Our experiments show a transition from brittle faulting to semibrittle faulting with an increase in both pressure and temperature. The yield behavior of samples deformed in the semibrittle regime follows a compactant elliptical cap at low strain, but evolves to a dilatant Mohr-Coulomb relationship with continued compaction. Optical microscopy indicates that semibrittle deformation involves cataclastic flow through shear-enhanced compaction and grain crushing; however, transmission electron microscopy shows evidence for dislocation glide in limited portions of samples. To constrain the relative contribution of brittle and crystal plastic mechanisms, we estimate the partitioning of the inelastic work into the dissipation energy for microcracking, intergranular frictional slip, and dislocation glide. We conclude that semibrittle deformation is accommodated primarily by cataclastic mechanisms, with only a limited contribution from crystal plasticity. Mechanical data, acoustic emission records, and analysis of surface energy all indicate the activation of subcritical cracking at elevated temperature. Hence, we infer that the enhancement of subcritical cracking is responsible for the transition to semibrittle flow through promoting distributed grain-scale fractures and millimeter-scale shear bands. Subcritical cracking promotes the nucleation of microfractures at lower stresses, and the resulting decrease in flow stress retards the propagation of transgranular microfractures. Our study illuminates the important role of temperature on the micromechanics of the transition from brittle faulting to cataclastic flow in the Earth.

  15. Short-circuit impedance measurement

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Nielsen, Arne Hejde; Poulsen, Niels Kjølstad

    2003-01-01

    Methods for estimating the short-circuit impedance in the power grid are investigated for various voltage levels and situations. The short-circuit impedance is measured, preferably from naturally occurring load changes in the grid, and it is shown that such a measurement system faces different...

  16. Impedance models in time domain

    NARCIS (Netherlands)

    Rienstra, S.W.

    2005-01-01

    Necessary conditions for an impedance function are derived. Methods available in the literature are discussed. A format with recipe is proposed for an exact impedance condition in time domain on a time grid, based on the Helmholtz resonator model. An explicit solution is given of a pulse reflecting

  17. Intraesophageal impedance monitoring: clinical studies

    NARCIS (Netherlands)

    Conchillo Armendáriz, J.M.

    2007-01-01

    Electrical impedance (Z) between two electrodes is the ratio between applied voltage (U) and resulting current (I). In electrical impedance monitoring the resistance to electrical flow in an alternating current circuit is measured. Multichannel esophageal monitoring can be measured by using an

  18. Quartz exposure and increased respiratory symptoms among coal ...

    African Journals Online (AJOL)

    Quartz has been an inevitable composition of different type of coal mined. The quartz exposures among coalmine workers has been attributed to activities such as cutting the adjacent rock, the roof, the floor and the intrusions. Objective: The aim of the study is to determine the associations between quartz exposures and ...

  19. Ag+ implantation in Al2O3, LiNbO3 and quartz

    International Nuclear Information System (INIS)

    Rahmani, M.; Townsend, P.D.

    1989-01-01

    Silver implantation in insulators produces colloids whose growth is a function of ion dose, ion energy, implant temperature and crystal orientation. Data for three materials are compared. Colloid growth is favoured by higher energy implants at temperatures where the silver is mobile. Preferential diffusion along the Z axis of Al 2 O 3 , LiNbO 3 and quartz results in a higher fraction of the implanted silver ions appearing in the form of colloids for Y cut crystals than for those of Z cut. Annealing characteristics also show a strong dependence on crystal cut. For the LiNbO 3 the colloids in Z cut crystals anneal most rapidly whereas for Al 2 O 3 those in Y cut material are least stable, their loss being accompanied by a reduction in F centres. (author)

  20. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding...

  1. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  2. Blue and red thermoluminescence of natural quartz in the temperature region from -196 to 400deg. C

    International Nuclear Information System (INIS)

    Hashimoto, Tetsuo; Yanagawa, Yuji; Yawata, Takashi

    2007-01-01

    Quartz samples of three different origins were γ-irradiated with 20kGy at room temperature or at the temperature of liquid nitrogen (-196 deg. C), and analyzed by on-line TL-emission spectrometry over two temperature ranges: above 200deg. C (high-temperature region) and -196 to 200deg. C (low-temperature region). The emission spectra in the high-temperature region could be separated into intense blue TL (BTL) or red TL (RTL) properties. All quartz samples displayed more or less both properties of BTL and RTL in the low temperature region, shifting the BTL-emission spectra towards violet. Particularly, volcanically originated quartz (RTL, Medeshima) showed highly complex BTL and RTL peaks in the low-temperature region, and a stronger simple RTL peak in the high temperature. These complex glow-curve peaks are considered to reflect the presence of many crystal defects and much content of impurities in the volcanically formed quartz. In the glow-curve measurements, Brazilian quartz (quartz-vein origin) gave weak RTL and intense BTL in the low-temperature range, followed by faint emission of BTL in the high-temperature side. On the other hand, the radiation-induced colored (CC) part of a Madagascan crystal rock slice (hydrothermal origin) showed intense BTL together with slight RTL in the low temperatures, followed by strong BTL and appreciable strength of RTL in the high temperatures. The BTL-emission pattern (TL-color image) of a Madagascan slice showed a complementary relationship between irradiations at liquid-nitrogen temperature and at room temperature. To explain these radiation-induced phenomena from quartz, hydrogen radicals and Li + ions, derived from radiolysis products of OH-related impurities, could operate to eliminate the BTL centers by recombination below the room temperature

  3. Emission polarization study on quartz and calcite.

    Science.gov (United States)

    Vincent, R. K.

    1972-01-01

    Calculation of the spectral emission polarization of quartz and calcite polished plates for observation angles of 20 and 70 deg by the substitution of complex index of refraction values for each mineral into Fresnel's equations. The emission polarization is shown to be quite wavelength-dependent, demonstrating that selected narrow or medium-width spectral bands exhibit a significantly higher percentage of polarization than a broad spectral band for these two minerals. Field measurements with a broadband infrared radiometer yield polarizations on the order of 2% for a coarse-grained granite rock and beach sand (both quartz-rich). This implies that a more sensitive detector with a selected medium-width filter may be capable of measuring emission polarization accurately enough to make this parameter useful as a remote sensing tool for discrimination among rocks on the basis of texture.

  4. Production of mineral aggregates in quartz tumbling experiments

    Science.gov (United States)

    Nørnberg, Per; Finster, Kai; Pall Gunnlaugsson, Haraldur; Knak Jensen, Svend; Merrison, Jonathan Peter

    2013-04-01

    Introduction Tumbling experiments with quartz sand with the purpose of tracing the effect of broken bonds in mineral surfaces resulted in an unexpected production of aggregates. These aggregates are a few microns in diameter, spherical and resembling tiny white "snowballs." Particle comminution by aeolian and other natural weathering processes are known in soil science and is often seen as an increase of fine particles towards the top of soil profiles (Nørnberg, P. 1987, 1988, 2002, J.S. Wright 2007). When mineral grains collide in aeolian processes they break up along weakness zones in the crystal lattice. This mechanism causes broken bonds between atoms in the crystal lattice and results in reactive groups in the mineral surface. This mechanism provides the background for experiments to investigate the oxidation processes of magnetite on the planet Mars. The primary magnetic iron oxide phase on Mars is to day known to be magnetite and the colour of the dust on Mars is most likely due to hematite. To investigate if the oxidation process could take place without going over dissolution and precipitation in water, experiments with tumbling of quartz grains in sealed glass containers along with magnetite were started. The idea was that activated bonds at the surface of quartz could oxidize magnetite and convert it to hematite over time. This proved to be the case (Merrison, J.P. et al. 2010). However, in these experiments we observed the formation of the white aggregates which has been the subject of the study that we present here. Results of tumbling experiments Commercially available quarts (Merck) was sieved to obtain the fraction between 125 and 1000 µm. This fraction was tumbled in glass containers for months and resulted in production of a significant amount of fine grained material (Merrison, J.P et al. 2010). A part of this fine fraction consists of the "snowball"-like aggregates which is a fragile element with relatively high specific surface. The physical

  5. Study of green quartz of hydrothermal origin treated by gamma radiation

    International Nuclear Information System (INIS)

    Enokihara, Cyro Teiti

    2013-01-01

    A specific variety of quartz showing a green color in nature or induced artificially by radiation is quite rare. This can be explained by the fact that the mechanism of formation of this color is very different from the ones widely discussed in the literature and responsible for the formation of the fumee, citrine and amethyst types of quartz, including the prasiolite (leak green quartz) formed by heating amethyst from Montezuma, Brazil. Only two occurrences are known today, where this type of quartz can be found: Canada, at the Thunder Bay Amethyst Mine, Ontario, a small district, and Brazil, at widely scattered geode occurrences along a 600 km stretch from Quarai at Brazils southernmost tip to Uberlandia in Minas Gerais. These two occurrences have been formed by strong hydrothermal activities, at Thunder Bay due to tectonics and in Brazil by meteoric and hydrothermal waters of the Guarani aquifer. That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects (twinning, small angle tilting, mosaic growth, striations) and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. This type of quartz can be considered 'wet quartz', similar to synthetic quartz. The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). There is no correlation between water content and cations as in other color varieties. Instead, silanol complexes are formed, which by radiation due to gamma rays form the color center NBOHC (non-bonding oxygen hole defect), showing absorption between 590 to 620 nm and leaving a transmission window at about 550nm, responsible for the green color. To characterize samples which will be colored green by gamma rays analyses by ICP, NAA, Electron microscopy, water loss techniques and UV-VIS and NIR-FTIR spectroscopic have been made. The spectroscopic water determination showed less water (up to 2300 ppm by weight) compared with

  6. Content of some microelements in Bulgarian quartz

    International Nuclear Information System (INIS)

    Kostadinov, K.; Kuleff, I.; Djingova, R.; Todorovski, D.

    1982-01-01

    Data on the content of As, Au, Ba, Br, Ca, Cd, Ce, Co, Cr, Cs, Eu, Fe, Hf, Hg, Ir, K, La, Lu, Mn, Nd, Na, Rb, Sb, Sm, Ta, Tb, Sc, Th, U, W, Yb, Zn obtained by instrumental neutron activation analysis are reported. The method is published elsewhere (Kuleff, I. et J. Radional. Chem. 62 (1981) 187). The results of other authors for the amount of Al, Li, Ti, obtained by atomic absorption spectrometry and Cu, P measured by destructive neutron activation analysis are also reported for 3 batches of electrothermal quartz glass, manufactured by ''Svetlina'' plant in Sliven, Bulgaria. The results for Bulgarian quartz glass are compared with literature and authors' data for similar quality glasses produced in England, France, FRG, GDR, USA and USSR. The results show that the amount of As, Au, Cd, Ce, Co, Cs, Eu, Hg, La, Ta, Yb in Bulgarian made quartz glass is lower than in a number of other similar glasses and the amount of the other impurities is close to the mean values. (authors)

  7. Kinetic model for quartz and spinel dissolution during melting of high-level-waste glass batch

    International Nuclear Information System (INIS)

    Pokorny, Richard; Rice, Jarrett A.; Crum, Jarrod V.; Schweiger, Michael J.; Hrma, Pavel

    2013-01-01

    The dissolution of quartz particles and the growth and dissolution of crystalline phases during the conversion of batch to glass potentially affects both the glass melting process and product quality. Crystals of spinel exiting the cold cap to molten glass below can be troublesome during the vitrification of iron-containing high-level wastes. To estimate the distribution of quartz and spinel fractions within the cold cap, we used kinetic models that relate fractions of these phases to temperature and heating rate. Fitting the model equations to data showed that the heating rate, apart from affecting quartz and spinel behavior directly, also affects them indirectly via concurrent processes, such as the formation and motion of bubbles. Because of these indirect effects, it was necessary to allow one kinetic parameter (the pre-exponential factor) to vary with the heating rate. The resulting kinetic equations are sufficiently simple for the detailed modeling of batch-to-glass conversion as it occurs in glass melters. The estimated fractions and sizes of quartz and spinel particles as they leave the cold cap, determined in this study, will provide the source terms needed for modeling the behavior of these solid particles within the flow of molten glass in the melter

  8. Nitrate-cancrinite precipitation on quartz sand in simulated Hanford tank solutions.

    Science.gov (United States)

    Bickmore, B R; Nagy, K L; Young, J S; Drexler, J W

    2001-11-15

    Caustic NaNO3 solutions containing dissolved Al were reacted with quartz sand at 89 degrees C to simulate possible reactions between leaked nuclear waste and primary subsurface minerals at the U.S. Department of Energy's Hanford site in Washington. Nitrate-cancrinite began to precipitate onto the quartz after 2-10 days, cementing the grains together. Estimates of the equilibrium constant for the precipitation reaction differ for solutions with 0.1 or 1.0 m OH- (log Keq = 30.4 +/- 0.8 and 36.2 +/- 0.6, respectively). The difference in solubility may be attributable to more perfect crystallinity (i.e., fewer stacking faults) in the higher-pH cancrinite structure. This is supported by electron micrographs of crystal morphology and measured rates of Na volatilization under an electron beam. Precipitate crystallinity may affect radionuclide mobility, because stacking faults in the cancrinite structure can diminish its zeolitic cation exchange properties. The precipitation rate near the onset of nucleation depends on the total Al and Si concentrations in solution. The evolution of experimental Si concentrations was modeled by considering the dependence of quartz dissolution rate on AI(OH)4- activity, cancrinite precipitation, and the reduction of reactive surface area of quartz due to coverage by cancrinite.

  9. Shock pressure estimation in basement rocks of the Chicxulub impact crater using cathodoluminescence spectroscopy of quartz

    Science.gov (United States)

    Tomioka, N.; Tani, R.; Kayama, M.; Chang, Y.; Nishido, H.; Kaushik, D.; Rae, A.; Ferrière, L.; Gulick, S. P. S.; Morgan, J. V.

    2017-12-01

    The Chicxulub impact structure, located in the northern Yucatan Peninsula, Mexico, was drilled by the joint IODP-ICDP Expedition 364 in April-May 2016. This expedition is the first attempt to obtain materials from the topographic peak ring within the crater previously identified by seismic imaging. A continuous core was successfully recovered from the peak ring at depths between 505.7 and 1334.7 mbsf. Uplifted, fractured, and shocked granitic basement rocks forming the peak ring were found below, in the impact breccia and impact melt rock unit (747.0-1334.7 mbsf; Morgan et al. 2016). In order to constrain impact crater formation, we investigated shock pressure distribution in the peak-ring basement rocks. Thin sections of the granitic rocks were prepared at intervals of 60 m. All the samples contains shocked minerals, with quartz grains frequently showing planar deformation features (PDFs). We determined shock pressures based on the cathodoluminescence (CL) spectroscopy of quartz. The strong advantage of the CL method is its applicability to shock pressure estimation for individual grains for both quartz and diaplectic SiO2 glass with high-spatial resolution ( 1 μm) (Chang et al. 2016). CL spectra of quartz shows a blue emission band caused by shock-induced defect centers, where its intensity increases with shock pressure. A total of 108 quartz grains in ten thin sections were analyzed using a scanning electron microscope with a CL spectrometer attached (an acceleration voltage of 15 kV and a beam current of 2 nA were used). Natural quartz single crystals, which were experimentally shocked at 0-30 GPa, were used for pressure calibration. CL spectra of all the quartz grains in the basement rocks showed broad blue emission band at the wavelength range of 300-500 nm and estimated shock pressures were in the range of 15-20 GPa. The result is consistent with values obtained from PDFs analysis in quartz using the universal stage (Ferrière et al. 2017; Rae et al. 2017

  10. Using quartz and plagioclase to gain insight into chemical and thermal evolution of the Rotoiti magma prior to the caldera-forming eruption {+-}55 ka, New Zealand

    Energy Technology Data Exchange (ETDEWEB)

    Smith, Victoria [Department of Earth Sciences, University of Bristol, Wills Memorial Building, Queen' s Road, Bristol BS8 1RJ (United Kingdom); Shane, Phil [School of Geography, Geology and Environmental Science, University of Auckland, Private Bag 92019, Auckland (New Zealand); Nairn, Ian [45 Summit Road, Rotorua RD5, New Zealand and GNS Science, Wairakei Research Centre, Taupo (New Zealand)], E-mail: Victoria.Smith@bristol.ac.uk

    2008-10-01

    The zoned plagioclase and quartz crystals within the multiple magmas that erupted during the {approx}55 ka Rotoiti caldera forming eruption appear to have had complex thermal and compositional histories. Compositional zoning suggests that magmatic systems were open, and received multiple pulses of hotter and more mafic magma. Limited diffusion across the crystals indicates that crystals did not dwell at magmatic temperatures for prolonged periods (<100 years), and suggest that the melts were generated and erupted quickly.

  11. Using quartz and plagioclase to gain insight into chemical and thermal evolution of the Rotoiti magma prior to the caldera-forming eruption ±55 ka, New Zealand

    International Nuclear Information System (INIS)

    Smith, Victoria; Shane, Phil; Nairn, Ian

    2008-01-01

    The zoned plagioclase and quartz crystals within the multiple magmas that erupted during the ∼55 ka Rotoiti caldera forming eruption appear to have had complex thermal and compositional histories. Compositional zoning suggests that magmatic systems were open, and received multiple pulses of hotter and more mafic magma. Limited diffusion across the crystals indicates that crystals did not dwell at magmatic temperatures for prolonged periods (<100 years), and suggest that the melts were generated and erupted quickly.

  12. Petrogenesis of low-δ18O quartz porphyry dykes, Koegel Fontein complex, South Africa

    Science.gov (United States)

    Harris, Chris; Mulder, Kwenidyn; Sarkar, Saheli; Whitehead, Benjamin; Roopnarain, Sherissa

    2018-04-01

    This paper investigates the origin of low-δ18O quartz porphyry dykes associated with the 144-133 Ma Koegel Fontein Igneous Complex, which was intruded during the initial phase of breakup of Africa and South America. The 25-km diameter Rietpoort Granite is the largest and youngest phase of activity, and is roofed by a 10-km diameter pendant of gneiss. Quartz porphyry (QP) dykes, up to 15 m in width, strike NW-SE across the complex. The QP dykes that intruded outside the granite have similar quartz phenocryst δ18O values (average 8.0‰, ± 0.7, n = 33) to the granite (average 8.3 ± 1.0, n = 7). The QP dykes that intruded the roof pendant have quartz phenocrysts with more variable δ18O values (average 1.6‰, ± 2.1, n = 55). In some cases quartz phenocrysts have δ18O values as low as - 2.5‰. The variation in δ18O value within the quartz crystal population of individual dykes is small relative to the overall range, and core and rim material from individual quartz phenocrysts in three samples are identical within error. There is no evidence that quartz phenocryst δ18O values have been affected by fluid-rock interaction. Based on a Δquartz-magma value of 0.6‰, magma δ18O values must have been as low as - 3.1‰. Samples collected along the length of the two main QP dykes that traverse the roof pendant have quartz phenocryst δ18O values that range from + 1.1 to + 4.6‰, and - 2.3 to + 5.6‰, respectively. These δ18O values correlate negatively ( r = - 0.96) with initial 87Sr/86Sr, which can be explained by the event that lowered δ18O values of the source being older than the dykes. We suggest that the QP dykes were fed by magma produced by partial melting of gneiss, which had been variably altered at high temperature by 18O-depleted meteoric water during global glaciation at 550 Ma. The early melts had variable δ18O value but as melt pockets interconnected during melting, the δ18O values approached that of average gneiss. Variable quartz phenocryst

  13. Development of early diagenetic silica and quartz morphologies — Examples from the Siri Canyon, Danish North Sea

    DEFF Research Database (Denmark)

    Weibel, Rikke; Friis, Henrik; Kazerouni, Afsoon Moatari

    2010-01-01

    in the following way: 1. Opal rims; characteristic of the initial phase of the silica diagenesis in most sandstone units in the Siri Canyon. Thick opal rims characterise the sandstone parts adjacent to the mudstone units in the Stine segment of the Siri Field. 2. Microquartz (quartz crystals with a size of 1–5 μm......); seen as coatings on the opal rims, both ordered and random. 3. Cavity overgrowth; found as quartz outgrowths in circular and angular cavities formed by dissolution of early authigenic phases. Angular cavities in the microquartz coatings origin from dissolution of clinoptilolite, possibly with a source...

  14. Characterization of color centers in quartz induced by gamma irradiation

    International Nuclear Information System (INIS)

    Guttler, Rainer A.S.

    2009-01-01

    The availability of gamma ray irradiators in Brazil increased the possibilities of treatments of gemstones for color enhancements. One of the minerals with a very high potential of these treatments is quartz, a very widespread mineral with much colored commercial varieties. Quartz occurs in Brazil mainly in two geological environments, called pegmatitic and hydrothermal. The detailed mechanism of color center formation of these two types of quartz will be investigated by spectroscopic and chemical analysis. Until yet, it can be shown that due to chemical differences of the nature of mineral forming fluids, the two types behave differently. All quartzes contain mainly traces of Iron, Aluminum, Lithium and some amounts of Water. The quartz of hydrothermal origin incorporated much structurally bound water, and despite some similarities with the chemical composition of pegmatitic quartz, this high water content is the reason for the formation of Silanol radicals, giving the green color to the quartz. The main difference in chemical composition of pegmatitic quartz is the presence of higher amounts of Al and Li , responsible for the brownish and yellowish colors formed by irradiation. Since each pegmatite is different, the quartz will behave differently. This explains the formation of the famous 'Green Gold' of quartz from Sao Jose da Safira , and the more yellowish, Citrine type, color of quartz from the Coluna deposit, near Itamarandiba, Minas Gerais. (author)

  15. Characterization of color centers in quartz induced by gamma irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Guttler, Rainer A.S., E-mail: rainersg@usp.b [Universidade de Sao Paulo (USP), SP (Brazil). Inst. de Geociencias; Enokihara, Cyro T.; Rela, Paulo R., E-mail: prela@ipen.b, E-mail: cteiti@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2009-07-01

    The availability of gamma ray irradiators in Brazil increased the possibilities of treatments of gemstones for color enhancements. One of the minerals with a very high potential of these treatments is quartz, a very widespread mineral with much colored commercial varieties. Quartz occurs in Brazil mainly in two geological environments, called pegmatitic and hydrothermal. The detailed mechanism of color center formation of these two types of quartz will be investigated by spectroscopic and chemical analysis. Until yet, it can be shown that due to chemical differences of the nature of mineral forming fluids, the two types behave differently. All quartzes contain mainly traces of Iron, Aluminum, Lithium and some amounts of Water. The quartz of hydrothermal origin incorporated much structurally bound water, and despite some similarities with the chemical composition of pegmatitic quartz, this high water content is the reason for the formation of Silanol radicals, giving the green color to the quartz. The main difference in chemical composition of pegmatitic quartz is the presence of higher amounts of Al and Li , responsible for the brownish and yellowish colors formed by irradiation. Since each pegmatite is different, the quartz will behave differently. This explains the formation of the famous 'Green Gold' of quartz from Sao Jose da Safira , and the more yellowish, Citrine type, color of quartz from the Coluna deposit, near Itamarandiba, Minas Gerais. (author)

  16. Optical properties and thermal stability of germanium oxide (GeO2) nanocrystals with α-quartz structure

    International Nuclear Information System (INIS)

    Ramana, C.V.; Carbajal-Franco, G.; Vemuri, R.S.; Troitskaia, I.B.; Gromilov, S.A.; Atuchin, V.V.

    2010-01-01

    Germanium dioxide (GeO 2 ) crystals were prepared by a chemical precipitation method at a relatively low-temperature (100 o C). The grown crystals were characterized by studying their microstructure, optical properties and thermal stability. The results indicate that the grown GeO 2 crystals exhibit α-quartz type crystal structure. The lattice parameters obtained from XRD were a = 4.987(4) A and c = 5.652(5) A. Electron microscopy analysis indicates a high structural quality of GeO 2 crystals grown using the present approach. Optical absorption measurements indicate a direct bandgap of 5.72 eV without any additional bands arising from localized or defect states. Thermogravimetric measurements indicate the temperature stability of the grown GeO 2 nanocrystals. Microscopic analysis coupled with energy dispersive X-ray spectroscopy of the GeO 2 crystals with α-quartz type crystal structure indicates their stability in chemical composition up to a temperature of 400 deg. C. The surface morphology of GeO 2 crystals, however, found to be changing with the increase in temperature.

  17. Hybrid-Source Impedance Networks

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    Hybrid-source impedance networks have attracted attention among researchers because of their flexibility in performing buck-boost energy conversion. To date, three distinct types of impedance networks can be summarized for implementing voltage-type inverters with another three types summarized...... for current-type inverters. These impedance networks can in principle be combined into two generic network entities, before multiple of them can further be connected together by applying any of the two proposed generalized cascading concepts. The resulting two-level and three-level inverters implemented using...

  18. Small Signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2014-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterized by the mechanical resonance between the mass of the diaphragm and the compliance of its suspension which vary...... from driver to driver. Therefore, a loudspeaker emulator capable of adjusting its impedance to that of a given driver is desired for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance with an electric circuit and that its resonance frequency can be changed by tuning two resistors....

  19. Identifying well-bleached quartz using the different bleaching rates of quartz and feldspar luminescence signals

    DEFF Research Database (Denmark)

    Murray, A.S.; Thomsen, Kristina Jørkov; Masuda, N.

    2012-01-01

    When dating older sedimentary deposits using quartz, there are no unambiguous methods for identifying the presence of incomplete bleaching. Current statistical analysis of dose distributions depends entirely on the assumption that incomplete bleaching and mixing are the main causes of any excess...... dispersion in the distribution; the only existing way to test this assumption is using independent age control. Here we suggest a new approach to this question, based on the differential bleaching rates of quartz and feldspar luminescence signals. We first present data that confirm the differences...... in relative bleaching rates of quartz optically stimulated luminescence (OSL) and feldspar luminescence stimulated at 50 °C by infrared light (IR50) and feldspar luminescence stimulated at 290 °C by infrared light after a stimulation at 50 °C (pIRIR290), and use recently deposited samples to determine...

  20. Experimental diagenesis of quartz with petroleum; Diagenese experimentale du quartz en presence d'hydrocarbures

    Energy Technology Data Exchange (ETDEWEB)

    Teinturier, St.

    2002-11-01

    Quartz cementation has a great impact on petroleum reservoir quality by controlling the porosity and thus the gas or oil storage. However, the possible cementation of quartz during petroleum emplacement is still debated. In most cases, the reconstitution and the understanding of diagenetic processes is based on fluid inclusions studies. However, many questions concerning the representativeness and the reading of the fluid inclusions still remains misunderstood. The experiments were carried out in a silica{+-}water{+-}salts{+-}oil{+-}gas system with the objective to simulate the siliceous diagenesis of natural petroleum reservoirs and to better understand the mechanisms of fluid inclusions formation and quartz cementation in a water and/or petroleum system. Calibration curves have been established using Raman micro-spectroscopy and synthetic reference inclusions to calculate the methane content of aqueous inclusions in the H{sub 2}O-CH{sub 4}-NaCl system. A quantitative procedure for FT-IR micro-spectrometry has been developed to obtain, from individual petroleum fluid inclusions, mole % concentrations of methane, alkanes and carbon dioxide as constraints to thermodynamic modelling. Synthetic aqueous inclusions were created within quartz micro-fractures, with methane (from 150 deg C-200 bar), with petroleum (from 184 deg C-163 bar) and inside quartz overgrowth with the presence of hydrocarbons (from 277 deg C-300 bar). Synthetic petroleum inclusions were created with different water/oil ratios (W/O) within quartz micro-fractures (0quartz overgrowth (10

  1. Characterization of high impedance connecting links for Bolometric detectors

    Energy Technology Data Exchange (ETDEWEB)

    Giachero, A. [INFN, Sezione di Milano Bicocca, Piazza della Scienza 3, I-20126 Milano (Italy); Università di Milano Bicocca, Dipartimento di Fisica G. Occhialini, Piazza della Scienza 3, I-20126 Milano (Italy); Gotti, C. [INFN, Sezione di Milano Bicocca, Piazza della Scienza 3, I-20126 Milano (Italy); Università di Milano Bicocca, Dipartimento di Fisica G. Occhialini, Piazza della Scienza 3, I-20126 Milano (Italy); Università di Firenze, Dipartimento di Elettronica e Telecomunicazioni, Via S. Marta 3, I-50139 Firenze (Italy); Maino, M. [INFN, Sezione di Milano Bicocca, Piazza della Scienza 3, I-20126 Milano (Italy); Università di Milano Bicocca, Dipartimento di Fisica G. Occhialini, Piazza della Scienza 3, I-20126 Milano (Italy); Pessina, G., E-mail: pessina@mib.infn.it [INFN, Sezione di Milano Bicocca, Piazza della Scienza 3, I-20126 Milano (Italy); Università di Milano Bicocca, Dipartimento di Fisica G. Occhialini, Piazza della Scienza 3, I-20126 Milano (Italy)

    2013-08-01

    High impedance connecting links and cables are tested at low frequency in terms of their parasitic impedance to ground and to neighboring connecting links. These parameters must be well characterized with detectors operated at low temperature, especially when the very front-end is at room temperature, which results in a long link. This is the case of the LUCIFER experiment, an array of crystals where every event of interest produces two signals, one composed of phonons, the other of photons. The parasitic impedance is usually considered to be the parallel combination of a resistance and a capacitance. We characterized both and found that from the static measurements the capacitance of the cable resulted much larger. On the basis of this result we optimized the measurement set-up and developed a model to account for this behavior.

  2. In situ anodization of aluminum surfaces studied by x-ray reflectivity and electrochemical impedance spectroscopy

    International Nuclear Information System (INIS)

    Bertram, F.; Evertsson, J.; Messing, M. E.; Mikkelsen, A.; Lundgren, E.; Zhang, F.; Pan, J.; Carlà, F.; Nilsson, J.-O.

    2014-01-01

    We present results from the anodization of an aluminum single crystal [Al(111)] and an aluminum alloy [Al 6060] studied by in situ x-ray reflectivity, in situ electrochemical impedance spectroscopy and ex situ scanning electron microscopy. For both samples, a linear increase of oxide film thickness with increasing anodization voltage was found. However, the slope is much higher in the single crystal case, and the break-up of the oxide film grown on the alloy occurs at a lower anodization potential than on the single crystal. The reasons for these observations are discussed as are the measured differences observed for x-ray reflectivity and electrochemical impedance spectroscopy.

  3. Kinetics of the coesite to quartz transformation

    Science.gov (United States)

    Mosenfelder, J.L.; Bohlen, S.R.

    1997-01-01

    The survival of coesite in ultrahigh-pressure (UHP) rocks has important implications for the exhumation of subducted crustal rocks. We have conducted experiments to study the mechanism and rate of the coesite ??? quartz transformation using polycrystalline coesite aggregates, fabricated by devitrifying silica glass cylinders containing 2850H/106 Si at 1000??C and 3.6 GPa for 24h. Conditions were adjusted following synthesis to transform the samples at 700-1000??C at pressures 190-410 MPa below the quartz-coesite equilibrium boundary. Reaction proceeds via grain-boundary nucleation and interface-controlled growth, with characteristic reaction textures remarkably similar to those seen in natural UHP rocks. We infer that the experimental reaction mechanism is identical to that in nature, a prerequisite for reliable extrapolation of the rate data. Growth rates obtained by direct measurement differ by up to two orders of magnitude from those estimated by fitting a rate equation to the transformation-time data. Fitting the rates to Turnbull's equation for growth therefore yields two distinct sets of parameters with similar activation energies (242 or 269 kJ/mol) but significantly different pre-exponential constants. Extrapolation based on either set of growth rates suggests that coesite should not be preserved on geologic time scales if it reaches the quartz stability field at temperatures above 375-400??C. The survival of coesite has previously been linked to its inclusion in strong phases, such as garnet, that can sustain a high internal pressure during decompression. Other factors that may play a crucial role in preservation are low fluid availability - possibly even less than that of our nominally "dry" experiments - and the development of transformation stress, which inhibits nucleation and growth. These issues are discussed in the context of our experiments as well as recent observations from natural rocks. ?? 1997 Elsevier Science B.V.

  4. Slaw extracted proton beam formation and monitoring for the ''QUARTZ'' setup

    International Nuclear Information System (INIS)

    Bushnin, Yu.B.; Gres', V.N.; Davydenko, Yu.P.

    1982-01-01

    The version of optical mode of the beam channel providing with simultaneous operating the experimental setups FODS and ''QUARTZ'' at consecutive usage of the slow extracted proton beam is reported. The ''QUARTZ'' setup beam diagnostics system comprises two subsystems: for measuring beam profile beam timing structure and beam intensity and operates in the beam extraction duration from 20 ns to few seconds at beam intensity from 10 10 to 5x10 12 protons/pulse. The ''QUARTZ'' setup represents a focusing crystal-diffraction spectrometer with 5-meter focal distance and Ge(Li) special construction detector. High efficiency target is applied in the setup. The ''QUARTZ'' setup is designed for studying exotic atoms produced by negative charged heavy particles (π, K, μ, P tilde) and atomic nuclei. Precise energy measurement of X ray transitions in such atoms is performed. For measuring beam geometric parameters 32-channel secondary emission chambers are used. As detector of beam intensity and timing structure of slow extracted beam the secondary emission chamber is employed. The principle circuit of current integrator is given. As data transmission line a 50-pair telephone cable is used. Information conversion into digital form and its subsequent processing is performed in the CAMAC system and the SM-3 computer. The proton beam full intensity measuring system provides with accuracy not worse than +-4.5% in the 10 10 -10 12 proton/sec range. The implemented optical mode of the beam channel and proton beam monitoring system permitted to begin fulfillment of the experimental program on the ''QUARTZ'' setup

  5. OH-point defects in quartz in B- and Li-bearing systems and their application to pegmatites

    Science.gov (United States)

    Baron, M. A.; Stalder, R.; Konzett, J.; Hauzenberger, C. A.

    2015-01-01

    OH incorporation in quartz in Al-, B- and Li-bearing systems (granitic systems containing tourmaline or spodumene) was studied experimentally in order to investigate the effect of pressure, temperature and chemical impurities on the generation of OH-defects. High-pressure experiments were carried out at pressures between 5 and 25 kbar and temperatures between 800 and 900 °C, and OH-contents in quartz were calculated from IR absorption spectra measured on oriented quartz crystals. IR absorption features were assigned to impurity substitutions, such as AlOH (3,420, 3,379 and 3,315 cm-1) and BOH (3,595 cm-1), LiOH (3,483 cm-1), and hydrogarnet substitution (4H)Si defects (3,583 cm-1). Results indicate a negative correlation of incorporated Al-specific OH-defect content versus pressure (630 ± 130 wt ppm H2O at 5 kbar to 102 ± 6 wt ppm H2O at 25 kbar), but no clear correlation of B-specific OH-defects with pressure. In runs initially containing spodumene, virtually OH-free quartzes were observed at pressures ≥10 kbar, where impurity cations compensate each other forming an anhydrous eucryptite-defect component. In contrast, at 5 kbar, both Li- ad Al-specific OH-defects are observed (corresponding to 470 ± 75 wt ppm H2O). Results from this study may therefore be used to monitor formation conditions of quartz in terms of pressure and trace metal saturation of the crystallizing petrological system. IR spectra obtained from natural quartz grains from a tourmaline-bearing pegmatite exhibit B- and Al-related OH-bands. The B-related OH-band is also exhibited in quartz from a tourmaline + spodumene-bearing pegmatite. Li- and Al-related OH-bands, however, are subordinate or not observed at all in the spodumene-bearing system, which suggests that OH-vibrations do not reflect absolute Li-contents in quartz due to efficient coupled substitution involving Al. Data from experimental runs and natural specimens indicate that the B-related OH-band can be used as a rough proxy for

  6. Significance of Dauphiné twins in crystallographic fabrics of quartz tectonites

    Science.gov (United States)

    Eske Sørensen, Bjørn

    2014-05-01

    Dauphine twins are commonly found in quartz tectonites, however their role in deformation processes are not completely understood. This study represents a new attempt to understand the interaction between slip systems and Dauphine twins in deforming quartz-rich rocks at different temperatures. There is no doubt that Dauphine twins are mobilized under stress as this has been shown by experiments for single crystals and in polycrystalline aggregates where distinct crystallographic fabrics develop in previously randomly oriented aggregates related to minimization of elastic energy (Tullis 1972). However in quartz tectonites the Dauphine twin process is a part of interplay between plastic deformation and recovery processes which depends on PT, strain-rate and fluid composition and availability. In quartz tectonites with Y-girdle C-axis (GBM-regime) fabrics Dauphiné twins are abundant, relating different parts of r- and z rhomb "comet" distributions. This is interpreted as completion between prism slip and Dauphiné twinning. Slip rotates grains such that CRSS is low on the prism planes, but then Dauphiné twin boundaries sweeps through the grain back to the orientation giving lower stored elastic energy. The faster recovery at higher temperatures gives subgrain walls slowing down twin movement across the mm-sized grain of the GBM regime. At lower temperatures in the SGR-regime grain-size is reduced and different rotations of the grains are happening due to the domination of rhomb and basal slip. Because recrystallization is effective relative to grain-size the grains are commonly free of internal strain and subgrain walls, allowing the favorably oriented Dauphiné twin member to sweep across the whole grain overwhelming the unfavorably oriented Dauphiné twin member. As a consequence high strain reduces the number of Dauphiné twins and quartz rhomb fabrics appear trigonal, missing the "comet" shape of the GBM regime rhomb fabrics. Since Dauphiné twinning is also

  7. Production of quartz plates for CMS-CASTOR Experiment

    CERN Document Server

    Adiguzel, Aytul; Ayhan, Aydin; Bakirci, Mustafa Numan; Basegmez, Suzan; Beaumont, Willem; Borras, Kerstin; Campbell, Alan; De Paula Carvalho, W; Çerçi, Salim; De Jesus Damiao, Dilson; Dogangün, O; Dumanoglu, Isa; d'Enterria, David; Erchov, Y; Eskut, Eda; Figueiredo, D; Girgis, Semiray; Göttlicher, P; Gouskos, Loukas; Gurpinar, Emine; Hos, Ilknur; Katkov, Igor; Katsas, Panagiotis; Khein, Lev; Knutsson, Albert; Kuznetsov, Andrey; Lebeau, Michel; Van Mechelen, Pierre; Muhl, Carsten; Musienko, Yuri; Ochesanu, Silvia; Onengüt, G; Onengut, G Jr; Ozdemir, Kadri; Panagiotou, Apostolos; Polatoz, A; Ripert, Marion; Shileev, K; Sogut, Kenan; Tiflov, B TaliV; Kayis-Topaksu, A; Uzun, Dilber

    2008-01-01

    Light transmission rate performance of $102$ irradiated quartz samples was measured to select the best quartz plates for CMS-CASTOR calorimeter. All the produced quartz plates were originally used in a previous CERN experiment, DELPHI. Three different doses of $^{60}$Co source were used with the collaboration of PSI (Paul Scherrer Institute, Villigen PSI, Switzerland.) to study the transmission rate performance of the quartz samples after irradiation for different incident light, ranging from $250$ to $700$ nm in $5$ nm increasing steps. All samples show different decrease in the rate with wavelength for different doses. Three different steps were followed before irradiation to find out the best way of cleaning the original DELPHI Cu/Cr tracks on the samples. Results of these measurements presented here correspond to the quartz plates that will be used in one hadronic sector of CASTOR calorimeter until end of 2008. For the full calorimeter new quartz plates will be installed. We also present the light transmi...

  8. Asymmetric adsorption of alanine by quartz powder from ethanol solution

    Energy Technology Data Exchange (ETDEWEB)

    Furuyama, Shozo; Sawada, Michio; Hachiya, Kinji; Morimoto, Tetsuo (Okayama Univ. (Japan). Faculty of Science)

    1982-11-01

    The asymmetric adsorption of the racemic alanine by the optically active quartz from ethanol solution at 8/sup 0/C was studied by the /sup 14/C-tracer method and the newly developed /sup 14/C-tracer ninhydrin-colorimetry combination method. The preferential adsorption of L-alanine by levorotatory quartz (l-quartz) and D-alanine by dextrorotatory quartz (d-quartz) was confirmed. The asymmetric adsorptivity (Asub(s)) falls in the range of 1.1 - 1.3, which is comparable with the value determined at - 80/sup 0/C in the previous paper. The effects of water content in the ethanol solution and of the adsorption temperature upon the adsorption affinity of alanine to quartz were also measured. The cause for the asymmetric adsorption is discussed from the crystallographic point of view.

  9. Fluid Inclusion Study of Quartz Xenocrysts in Mafic Dykes from Kawant Area, Chhota Udaipur District, Gujarat, India

    Directory of Open Access Journals (Sweden)

    Randive Kirtikumar

    2015-09-01

    Full Text Available Unusual mafic dykes occur in the proximity of the Ambadongar Carbonatite Complex, Lower Narmada Valley, Gujarat, India. The dykes contain dense population of quartz xenocrysts within the basaltic matrix metasomatised by carbonate-rich fluids. Plagioclase feldspars, relict pyroxenes, chlorite, barite, rutile, magnetite, Fe-Ti oxides and glass were identified in the basaltic matrix. Quartz xenocrysts occur in various shapes and sizes and form an intricate growth pattern with carbonates. The xenocrysts are fractured and contain several types of primary and secondary, single phase and two-phase fluid inclusions. The two-phase inclusions are dominated by aqueous liquid, whereas the monophase inclusions are composed of carbonic gas and the aqueous inclusions homogenize to liquid between 226°C and 361°C. Majority of the inclusions are secondary in origin and are therefore unrelated to the crystallization of quartz. Moreover, the inclusions have mixed carbonic-aqueous compositions that inhibit their direct correlation with the crustal or mantle fluids. The composition of dilute CO2-rich fluids observed in the quartz xenocrysts appear similar to those exsolved during the final stages of evolution of the Amba Dongar carbonatites. However, the carbonates are devoid of fluid inclusions and therefore their genetic relation with the quartz xenocrysts cannot be established.

  10. Impedance and ac conductivity studies of Ba (Pr1/2Nb1/2) O3 ceramic

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 36; Issue 4. Impedance and a.c. conductivity studies of ... Abstract. Impedance and electrical conduction studies of Ba(Pr1/2Nb1/2)O3 ceramic prepared through conventional ceramic fabrication technique are presented. The crystal symmetry, space group and unit cell ...

  11. Y-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    This letter introduces a new versatile Y-shaped impedance network for realizing converters that demand a very high-voltage gain, while using a small duty ratio. To achieve that, the proposed network uses a tightly coupled transformer with three windings, whose obtained gain is presently not matched...... by existing networks operated at the same duty ratio. The proposed impedance network also has more degrees of freedom for varying its gain, and hence, more design freedom for meeting requirements demanded from it. This capability has been demonstrated by mathematical derivation, and proven in experiment...

  12. Cosmic ray production rates of Be-10 and Al-26 in quartz from glacially polished rocks

    Science.gov (United States)

    Nishiizumi, K.; Kohl, C. P.; Winterer, E. L.; Klein, J.; Middleton, R.

    1989-01-01

    The concentrations of Be-10 and Al-26 in quartz crystals extracted from glacially polished granitic surfaces from the Sierra Nevada range are studied. These surfaces are identified with the glacial advance during the Tioga period about 11,000 yr ago. The measurements yield the most accurate estimates to date for the absolute production rates of three nuclides in SiO2 due to cosmic ray nucleons and muons for geomagnetic latitudes 43.8-44.6 N and altitudes 2.1-3.6 km.

  13. Stresses and pressures at the quartz-coesite transition in shear experiments

    Science.gov (United States)

    Richter, B.; Stunitz, H.; Heilbronner, R.

    2015-12-01

    Experiments on quartz (qtz) gouge were performed in a Griggs-type deformation apparatus at displacement rates of ~1.3 x 10-5 mms-1 or ~1.3 x 10-4 mms-1, at Pc= 1.0 GPa or 1.5 GPa and T = 600°C to 800°C. The starting material is a natural hydrothermally grown single crystal that was crushed to a powder with grain size d reaction from coe to qtz is observed. It appears therefore that the pressure that defines the QCT is not Pc or Pm, but σ1.

  14. Opalescence of quartz: a study by high energy x-ray diffraction

    Science.gov (United States)

    Bastie, P.; Dolino, G.; Hamelin, B.

    2003-05-01

    The origin of the opalescence observed at the α-β transition of quartz remains an open question. This intense light scattering occurs during the coexistence, at the first order transition, of the α and incommensurate (inc) phases, in the vicinity of the phase interface. New hard x-ray diffraction experiment shows that the large angle light scattering is mainly in the α-phase region of the crystal and reveals the existence of an intermediate structure between the α-phase and the 3q inc phase.

  15. Opalescence of quartz: a study by high energy x-ray diffraction

    Energy Technology Data Exchange (ETDEWEB)

    Bastie, P [Laboratoire de Spectrometrie Physique, Universite Joseph Fourier-Grenoble 1 - CNRS, UMR No 5588, BP 87, 38402 Saint Martin d' Heres Cedex (France); Dolino, G [Laboratoire de Spectrometrie Physique, Universite Joseph Fourier-Grenoble 1 - CNRS, UMR No 5588, BP 87, 38402 Saint Martin d' Heres Cedex (France); Hamelin, B [Institut Laue Langevin, BP 156X, 38042 Grenoble Cedex 9 (France)

    2003-05-21

    The origin of the opalescence observed at the {alpha}-{beta} transition of quartz remains an open question. This intense light scattering occurs during the coexistence, at the first order transition, of the {alpha} and incommensurate (inc) phases, in the vicinity of the phase interface. New hard x-ray diffraction experiment shows that the large angle light scattering is mainly in the {alpha}-phase region of the crystal and reveals the existence of an intermediate structure between the {alpha}-phase and the 3q inc phase.

  16. Evidence of a Love wave bandgap in a quartz substrate coated with a phononic thin layer

    International Nuclear Information System (INIS)

    Liu, Ting-Wei; Wu, Tsung-Tsong; Lin, Yu-Ching; Tsai, Yao-Chuan; Ono, Takahito; Tanaka, Shuji

    2014-01-01

    This paper presents a numerical and experimental study of Love wave propagation in a micro-fabricated phononic crystal (PC) structure consisting of a 2D, periodically etched silica film deposited on a quartz substrate. The dispersion characteristics of Love waves in such a phononic structure were analyzed with various geometric parameters by using complex band structure calculations. For the experiment, we adopted reactive-ion etching with electron-beam lithography to fabricate a submicrometer phononic structure. The measured results exhibited consistency with the numerical prediction. The results of this study may serve as a basis for developing PC-based Love wave devices

  17. Resonant frequency function of thickness-shear vibrations of rectangular crystal plates.

    Science.gov (United States)

    Wang, Ji; Yang, Lijun; Pan, Qiaoqiao; Chao, Min-Chiang; Du, Jianke

    2011-05-01

    The resonant frequencies of thickness-shear vibrations of quartz crystal plates in rectangular and circular shapes are always required in the design and manufacturing of quartz crystal resonators. As the size of quartz crystal resonators shrinks, for rectangular plates we must consider effects of both length and width for the precise calculation of resonant frequency. Starting from the three-dimensional equations of wave propagation in finite crystal plates and the general expression of vibration modes, we obtained the relations between frequency and wavenumbers. By satisfying the major boundary conditions of the dominant thickness-shear mode, three wavenumber solutions are obtained and the frequency equation is constructed. It is shown the resonant frequency of thickness-shear mode is a second-order polynomial of aspect ratios. This conforms to known results in the simplest form and is applicable to further analytical and experimental studies of the frequency equation of quartz crystal resonators.

  18. Quartz: structural and thermodynamic analyses across the α ↔ β transition with origin of negative thermal expansion (NTE) in β quartz and calcite

    Energy Technology Data Exchange (ETDEWEB)

    Antao, Sytle M.

    2016-04-01

    The temperature variation,T, of the crystal structure of quartz, SiO2, from 298 to 1235 K was obtained with synchrotron powder X-ray diffraction data and Rietveld structure refinements. The polymorphic transformation fromP3221 (low-T, α quartz) toP6222 (high-T, β quartz) occurs at a transition temperature,Ttr= 847 K. TheTvariations of spontaneous strains and several structural parameters are fitted to an order parameter,Q, using Landau theory. The change in Si atom coordinate, Six, givesTtr-Tc= 0.49 K, which indicates an α ↔ β transition that is weakly first order and nearly tricritical in character (Q4T). Strains give higherTtr-Tcvalues (≃ 7 K). Other fitted parameters are the oxygen Ozcoordinate, Si—Si distance, Si—O—Si and φ angles, and intensity of the (111) reflection,I111. In α quartz, the Si—Si distance increases withTbecause of cation repulsion, so the Si—O—Si angle increases (and φ decreases) and causes the thermal expansion of the framework structure that consists of corner-sharing distorted rigid SiO4tetrahedra. The Si—Si distances contract withTand cause negative thermal expansion (NTE) in β quartz because of increasing thermal librations of the O atom in the Si—O—Si linkage that occur nearly perpendicular to the Si—Si contraction. In calcite, CaCO3, the short Ca—Ca distance expands withT, but the next-nearest Ca—Ca distance, which is of equal length to theaaxis, contracts withTand causes NTE along

  19. Quartz enhanced photoacoustic spectroscopy based trace gas sensors using different quartz tuning forks.

    Science.gov (United States)

    Ma, Yufei; Yu, Guang; Zhang, Jingbo; Yu, Xin; Sun, Rui; Tittel, Frank K

    2015-03-27

    A sensitive trace gas sensor platform based on quartz-enhanced photoacoustic spectroscopy (QEPAS) is reported. A 1.395 μm continuous wave (CW), distributed feedback pigtailed diode laser was used as the excitation source and H2O was selected as the target analyte. Two kinds of quartz tuning forks (QTFs) with a resonant frequency (f0) of 30.72 kHz and 38 kHz were employed for the first time as an acoustic wave transducer, respectively for QEPAS instead of a standard QTF with a f0 of 32.768 kHz. The QEPAS sensor performance using the three different QTFs was experimentally investigated and theoretically analyzed. A minimum detection limit of 5.9 ppmv and 4.3 ppmv was achieved for f0 of 32.768 kHz and 30.72 kHz, respectively.

  20. Quartz Enhanced Photoacoustic Spectroscopy Based Trace Gas Sensors Using Different Quartz Tuning Forks

    Directory of Open Access Journals (Sweden)

    Yufei Ma

    2015-03-01

    Full Text Available A sensitive trace gas sensor platform based on quartz-enhanced photoacoustic spectroscopy (QEPAS is reported. A 1.395 μm continuous wave (CW, distributed feedback pigtailed diode laser was used as the excitation source and H2O was selected as the target analyte. Two kinds of quartz tuning forks (QTFs with a resonant frequency (f0 of 30.72 kHz and 38 kHz were employed for the first time as an acoustic wave transducer, respectively for QEPAS instead of a standard QTF with a f0 of 32.768 kHz. The QEPAS sensor performance using the three different QTFs was experimentally investigated and theoretically analyzed. A minimum detection limit of 5.9 ppmv and 4.3 ppmv was achieved for f0 of 32.768 kHz and 30.72 kHz, respectively.

  1. Comparative study of the thermoluminescence properties of natural metamorphic quartz belonging to Turkey and Spain

    International Nuclear Information System (INIS)

    Topaksu, M.; Dogan, T.; Yüksel, M.; Kurt, K.; Topak, Y.; Yegingil, Z.

    2014-01-01

    The aim of this study is to investigate the sensitization of the thermoluminescence (TL) peak of metamorphic quartzes from Adiyaman in Turkey (TMQ) and from Madrid in Spain (SMQ). Quartz samples of two different origins were β-irradiated between ∼6.689 Gy and 4816 Gy at room temperature. X-ray diffraction analysis has indicated that both TMQ and SMQ have the same crystal structure. Chemical analyses of both TMQ and SMQ were performed using the XRF technique. The preheat processes were carried out at 125 °C for 10 s in the TL measurement. TMQ and SMQ samples have different TL properties in two ways. First TMQ has four first order TL glow peaks while SMQ has five first order TL peaks and secondly, the observed dose sensitivity of TMQ samples is higher than the SMQ samples. - Highlights: • The thermoluminescence (TL) peak of metamorphic quartzes was investigated. • Comparable differences were seen between low and high dose levels. • AD and CGCD methods were used

  2. Titanium zoning and diffusion chronometry reveal dynamic and late-stage quartz growth in the Youngest Toba Tuff, Indonesia

    Science.gov (United States)

    Tierney, C. R.; Reid, M. R.; Burns, D. H.; Costa Rodriguez, F.; Chesner, C. A.

    2017-12-01

    The enormous 74 ka Youngest Toba Tuff (YTT) ejected 2800 km3 of compositionally zoned (68-77 wt.% SiO2) ignimbrite and co-ignimbrite ash. Titanium zoning within YTT quartz records a dynamic growth history, and sometimes concludes with a final growth stage under different conditions. We investigated the timescales of quartz growth using diffusion chronometry, and determined whether the last stage of crystallization was the result of a discrete and chamber-wide magmatic event. This work offers insight into the dynamics and timescales of storage and remobilization of voluminous silicic magmas - an important consideration for hazards assessment. High-resolution (1 µm steps) hyperspectral CL was mapped from 5-20 quartz crystals from each of five pumices spanning the YTT compositional spectrum. CL intensity was calibrated to Ti concentration via EPMA, and numerically modeled time-dependent diffusional relaxation curves where fit to concentration profiles across zone boundaries. CL-bright/high-Ti rims are found in quartz from all samples, but become less common and have lower Ti concentrations with increasing host pumice silica content (e.g., 70 ppm vs 50 ppm). Some large crystals contain distinct CL-bright interior zones with similar Ti concentration to the rims. Onset of growth of CL-bright rims commenced between 15 and 100 years before eruption, and interior bands between 30 and 1500 years. Neither rim nor interior ages correlate significantly with host pumice silica. Rim growth on quartz evidently occurred closer to eruption than a previous estimate of several decades to centuries for quartz from a single YTT pumice (Matthews et al., 2012). The similar timing for the onset of high-Ti quartz rim growth across all samples suggests a marked and temporally discrete magmatic event in the years to decades prior to eruption and may be recording the chamber-wide influence of magmatic recharge or remobilization. High-Ti interior zones likely record older recharge events that

  3. Passivation of quartz for halogen-containing light sources

    Science.gov (United States)

    Falkenstein, Zoran

    1999-01-01

    Lifetime of halogen containing VUV, UV, visible or IR light sources can be extended by passivating the quartz or glass gas containers with halogens prior to filling the quartz with the halogen and rare gas mixtures used to produce the light.

  4. Refractometry characteristics of α-quartz after neutron irradiation

    International Nuclear Information System (INIS)

    Abdkadyrova, I.Kh.

    1997-01-01

    Lattice structure distortions in irradiated crystalline quartz were studied by refractometry methods. The refractometry constants of α-quartz for the flux of fast neutrons 10 18 - 10 21 neutron/cm 2 were calculated. The critical kinetics of this constants at the phase transformation is observed.(author). 5 refs., 1 fig

  5. Thermal quenching of thermoluminescence in quartz samples of various origin

    International Nuclear Information System (INIS)

    Subedi, B.; Oniya, E.; Polymeris, G.S.; Afouxenidis, D.; Tsirliganis, N.C.; Kitis, G.

    2011-01-01

    The effect of thermal quenching stands among the most important properties in the thermoluminescence (TL) of quartz on which many applications of TL are based. Since the quartz samples used in various applications are all of different origin it is useful to investigate whether the values of the thermal quenching parameters, i.e. the activation energy for thermal quenching W and a parameter C which describes the ratio of non-radiative to radiative luminescence transitions, evaluated mainly in specific quartz samples can be extrapolated to quartz samples of unknown origin as well as to quartz samples which are annealed at high temperatures. In the present work the TL glow curve of a series of un-annealed and annealed natural and synthetic quartz samples were studied as a function of the heating rate between 0.25 K/s and 16 K/s. Using an indirect fitting method it was found that the thermal quenching parameters W and C in most of the quartz samples are very similar to the values accepted in the literature. Furthermore, in some cases the thermal quenching parameters W and C are not the same for all TL glow-peaks in the same glow-curve. Finally, the strong external treatment of annealing the quartz samples at very high temperature can also influence at least one of the thermal quenching parameters.

  6. Red and blue colouration of thermoluminescence from natural quartz sands

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, T; Hayashi, Y; Koyanagi, A; Yokosaka, K; Kimura, K

    1986-01-01

    Quartz extracts, from a pegmatite rock, volcanic ashes and beach sands, were exposed to X-rays or gamma-rays upto 8.8kGy. The irradiated sands were observed through a thermoluminescence colour image technique (abbreviated to TLCI by the authors) using highly sensitive colour photographic system. The quartz sands from volcanic ash layers, containing ..beta..-quartz (mineralized at high temperature), always indicate a red TLCI, whereas the quartz rocks from pegmatite origin and granite strata, containing ..cap alpha..-quartz (mineralized at low temperature), gave a typical blue TLCI, being consistent with the well known quartz TL colour. Quartz fractions from the beach sands showed a mixture of both red and blue TLCI, probably reflecting the respective mixtures of ..beta..-(in their origin) and ..cap alpha..-quartz fractions along the riverside area. The search using X-ray diffractometry and instrumental neutron activation analysis proved that the cause of distinctly different colourations was attributable to the impurity atoms: light rare earth elements (Eu and/or Sm) bringing on red TLCI, while structural defects yielding the blue TLCI).

  7. Anisotropic viscoelastic properties of quartz and quartzite in the vicinity of the α- β phase transition

    Science.gov (United States)

    Klumbach, Steffen; Schilling, Frank R.

    2017-10-01

    In this study we performed high-temperature, dynamic (i.e. sinusoidal), three-point bending experiments of quartz single crystals and quartzite samples within the frequency range of seismic surveys (i.e. 0.1-20 Hz). At constant temperature close to the α- β phase transition we observed a unique complex elastic behaviour of both quartz and quartzite. We find a frequency dependence of the complex Young's modulus of α-quartz, including a dissipation maximum at ≈1 Hz supposedly related to the formation and variation of Dauphiné twin domains. Based on our experimental results for different crystallographic directions and additional modelling, we are able to describe the complex Young's modulus of quartz at its α- β phase transition in a 3D diagram. We derive a frequency-dependent elasticity tensor, using a three-element equivalent circuit, composed of two springs E 1 and E 2 as well as a dashpot η. E 1 and η are connected parallel to each other, E 2 is added in series. Compliance coefficients yield ( S 11) E 1 = 572 GPa, E 2 = 70.0 GPa, η = 64.6 GPa·s, ( S 33) E 1 = 127 GPa, E 2 = 52.1 GPa, η = 22.9 GPa·s, ( S 44) E 1 = 204 GPa, E 2 = 37.5 GPa, η = 26.4 GPa·s, ( S 12) E 1 = 612 GPa, E 2 = 106.7 GPa, η = 78.5 GPa·s, ( S 13) E 1 = 1546 GPa, E 2 = 284 GPa, η = 200 GPa·s; S 14 ≈-0.0024 GPa-1. We use the derived direction-dependent coefficients to predict the frequency-dependent complex elastic properties of isotropic polycrystalline quartz. These predictions agree well with the experimental results of the investigated quartzite. Finally, we explore the potential of using the anomalous frequency-dependent complex elastic properties of quartz at the α- β phase transition that we observed as an in situ temperature probe for seismic studies of the Earth's continental crust.

  8. Activation analysis of high pure quartz used as packing materials

    International Nuclear Information System (INIS)

    Luknitskij, V.A.; Morozov, B.A.

    1979-01-01

    A γ-spectrometric technique of neutron activation determination of microelements in quartz tubes used as a packing material for irradiation in reactors is reported. The analysis of 29 micro-admixtures in quartz tubes of USSR brands ''spectrtosil'' and ''KV'' was carried out. The γ-spectra of ''KV'' quartz irradiated by thermal and epithermal neutrons are presented. The activation by epithermal neutrons provides an activity gain for the nuclei whose resonance integral is high enough as compared to the activation cross-section with regard to thermal neutrons. The activation by epithermal neutrons permits additional determination of W, Cd, V, Th, Mn and Ni and provides for a substantial decrease in the activity of 24 Na, 42 K, 140 La, 46 Sc, 141 Ce, 51 Cr, and 59 Fe, which hinder the determination of the above-mentioned elements. The microelement composition of Soviet-made quartz varieties is compared to that of foreign-made quartz brands

  9. Microwave GaAs Integrated Circuits On Quartz Substrates

    Science.gov (United States)

    Siegel, Peter H.; Mehdi, Imran; Wilson, Barbara

    1994-01-01

    Integrated circuits for use in detecting electromagnetic radiation at millimeter and submillimeter wavelengths constructed by bonding GaAs-based integrated circuits onto quartz-substrate-based stripline circuits. Approach offers combined advantages of high-speed semiconductor active devices made only on epitaxially deposited GaAs substrates with low-dielectric-loss, mechanically rugged quartz substrates. Other potential applications include integration of antenna elements with active devices, using carrier substrates other than quartz to meet particular requirements using lifted-off GaAs layer in membrane configuration with quartz substrate supporting edges only, and using lift-off technique to fabricate ultrathin discrete devices diced separately and inserted into predefined larger circuits. In different device concept, quartz substrate utilized as transparent support for GaAs devices excited from back side by optical radiation.

  10. FEM Analysis of Beam-coupling Impedance and RF Contacts Criticality on the LHC UA9 Piezo Goniometer

    CERN Document Server

    Danisi, A; Passarelli, A; Masi, A; Losito, R; Salvant, B

    2014-01-01

    The UA9 piezo-goniometer has been designed to guarantee micro-radians-accuracy angular positioning of a silicon crystal for a crystal collimation experiment in the LHC, and to minimize the impact on the LHC beam coupling impedance. This paper presents a Finite Element Method (FEM) study of the device, in both parking and operational positions, to evaluate its impact on the LHC impedance budget. In addition, the shielding contribution of the RF gaskets has been carefully evaluated, with the objective to assess the consequences for operation in case of their failure. A final word is drawn on the overall device impedance criticality.

  11. Gamma radiation of quartz from Entre Rios (SC) and QuaraÍ (RS)

    International Nuclear Information System (INIS)

    Enokihara, Cyro T.; Rela, Paulo R.; Schultz-Güttler, Rainer A.

    2017-01-01

    The availability of gamma ray irradiators in Brazil increased the possibilities of treatments of gemstones for color enhancements. One of the minerals with a very high potential of these treatments is quartz, a very widespread mineral with many colored commercial varieties. A specific variety of quartz showing a green color in nature or induced artificially by radiation gamma ( 60 Co) is quite rare. In Brazil the widely scattered geode occurrences along a 600 km stretch from Quaraí at Brazil southernmost tip to Uberlandia in Minas Gerais is one of these. Quartz from these occurrences have been formed by strong hydrothermal activities. That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. In the present work the material analyzed is from hydrothermal regimes located near the towns Entre Rios (SC) and Quaraí (RS). To characterize these materials analyses have been made by ICP, NAA, electron microscopy, water loss techniques and UV-VIS and NIR-FTIR spectroscopic measurements. Silanol complexes are found, which by radiation due to gamma rays form the color center NBOHC (Non-Bonding Oxygen Hole Center), showing absorption between 590 to 620 nm and leaving a transmission window at about 550nm, responsible for the green color. The spectroscopic water determination showed less molecular water (up to 2300 ppm by weight), probably due to remaining silanol complexes.The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). (author)

  12. Gamma radiation of quartz from Entre Rios (SC) and QuaraÍ (RS)

    Energy Technology Data Exchange (ETDEWEB)

    Enokihara, Cyro T.; Rela, Paulo R., E-mail: cteiti@ipen.br, E-mail: prela06@yahoo.com.br [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil); Schultz-Güttler, Rainer A., E-mail: rainersgut@gmail.com [Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Instituto de Geociências

    2017-07-01

    The availability of gamma ray irradiators in Brazil increased the possibilities of treatments of gemstones for color enhancements. One of the minerals with a very high potential of these treatments is quartz, a very widespread mineral with many colored commercial varieties. A specific variety of quartz showing a green color in nature or induced artificially by radiation gamma ({sup 60}Co) is quite rare. In Brazil the widely scattered geode occurrences along a 600 km stretch from Quaraí at Brazil southernmost tip to Uberlandia in Minas Gerais is one of these. Quartz from these occurrences have been formed by strong hydrothermal activities. That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. In the present work the material analyzed is from hydrothermal regimes located near the towns Entre Rios (SC) and Quaraí (RS). To characterize these materials analyses have been made by ICP, NAA, electron microscopy, water loss techniques and UV-VIS and NIR-FTIR spectroscopic measurements. Silanol complexes are found, which by radiation due to gamma rays form the color center NBOHC (Non-Bonding Oxygen Hole Center), showing absorption between 590 to 620 nm and leaving a transmission window at about 550nm, responsible for the green color. The spectroscopic water determination showed less molecular water (up to 2300 ppm by weight), probably due to remaining silanol complexes.The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). (author)

  13. Calculation of effective impedance of polycrystals in weak magnetic fields

    International Nuclear Information System (INIS)

    Kaganova, I.M.

    2006-01-01

    We present results for the effective surface impedance tensor (EIT) of polycrystals of metals in a weak uniform magnetic field H. The frequency region corresponds to the region in which the local impedance boundary conditions are applicable. We suppose that the resistivity tensor ρ ik (H) of the single crystal grains out of which the polycrystal is composed, is known up to the terms of O(H 2 ). For polycrystals of metals of arbitrary symmetry, the elements of the EIT can be calculated to the same order in H, even if the tensor ρ ik (H) is strongly anisotropic. As examples, we write down the EIT of polycrystals of (i) cubic metals (ii) metals with ellipsoidal Fermi surfaces, and (iii) metals of tetragonal symmetry whose tensor ρ ik (0) is strongly anisotropic. Although polycrystals are metals that are isotropic on average, in the presence of a uniform magnetic field the structure of the EIT is not the same as the structure of the impedance tensor of an isotropic metal with a spherical Fermi surface. The results cannot be improved either by taking into account higher powers of H, or with respect to the anisotropy of the single crystal grains

  14. Peculiar Feldspar And Quartz Inclusions Within Zircons From Anorthosites, North Eastern Desert, Egypt

    Science.gov (United States)

    Eliwa, H. A.; Dawoud, M. I.; Khalaf, I. M.; Negendank, J. F.; Itaya, T.

    2004-12-01

    Zircons from three anorthosite outcrops along Wadi Dib area, north Eastern Desert of Egypt contain abundant and conspicuous inclusions of quartz, feldspar, amphibole and apatite. These anorthosites, as (50-100m thick) layers, represent the top of mafic-ultramafic intrusions exhibiting rhythmic layering visible by reputation of melanocratic and leucocratic layers. Field and microscopic studies exhibit that these anorthosites were affected by the action of residual magmatic solutions associated with the late stage crystallization of the younger granites, which modified their mineralogical composition. They are composed totally of plagioclase with subordinate amount of clinoenstatite, augite, amphibole, biotite, K-feldspar, and quartz. Accessories are magnetite, ilmenite, apatite and zircon. The abundance and the mode of occurrence of K-feldspar, quartz, and biotite with apatite and zircon among the megacrysts suggest their formation is ascribed to the interaction with the residual solutions. The microprobe data exhibit difference between feldspar and amphiboles contained herein zircons and those as anorthosite mineral constituents. The genetic relationship between zircons and their inclusions suggests later growth of zircons than inclusions and most probably at the final stage of rock modification. Zircons are magmatic and found in the interstitial feldspar and quartz among plagioclase megacrysts in aggregates or as individual grains. The microscopic and SEM images investigation exhibit that most zircons are subhedral to euhedral equant and prismatic crystals. Most zircons have same range of crystal morphologies and internal growth structures with predominance of prism /{100/} and pyramid /{101/} and occasionally prism /{110/} and pyramid /{111/}. No evidences for poly-faceted grains, inherited cores or later overgrowths were detected. CL images distinguished zircons with visible core-rim structures and others with regular and continuous growth zones contained herein

  15. Circular patterns of calcium oxalate monohydrate induced by defective Langmuir-Blodgett film on quartz substrates

    Energy Technology Data Exchange (ETDEWEB)

    He Jieyu [Institute of Biomineralization and Lithiasis Research, Jinan University, Guangzhou 510632 (China); Institute of Biomineralization and Lithiasis Research, Jinan University, Guangzhou 510632 (China); Ouyang Jianming [Institute of Biomineralization and Lithiasis Research, Jinan University, Guangzhou 510632 (China); Institute of Biomineralization and Lithiasis Research, Jinan University, Guangzhou 510632 (China)], E-mail: toyjm@jnu.edu.cn

    2009-01-01

    The defective Langmuir-Blodgett (LB) film of dipalmitoylphosphatidylcholine (DPPC) on quartz injured by potassium oxalate (K{sub 2}C{sub 2}O{sub 4}) was used as a model system to induce growth of calcium oxalate crystals. Atomic force microscopy (AFM) indicated that circular defective domains with a diameter of 1-200 {mu}m existed in the LB film. Scanning electron microscopy (SEM) showed circular patterns of aggregated calcium oxalate monohydrate (COM) crystallites were induced by these defective domains. It was ascribed to that the interaction between the negatively-charged oxalate ions and the phosphatidyl groups in DPPC headgroups makes the phospholipid molecules rearranged and exist in an out-of-order state in the LB film, especially at the boundaries of liquid-condensed (LC)/liquid-expanded (LE) phases, which provide much more nucleating sites for COM crystals.

  16. Highly efficient transparent Zn2SiO4:Mn2+ phosphor film on quartz glass

    International Nuclear Information System (INIS)

    Seo, K.I.; Park, J.H.; Kim, J.S.; Kim, G.C.; Yoo, J.H.

    2009-01-01

    Highly efficient transparent Zn 2 SiO 4 :Mn 2+ film phosphors on quartz substrates were deposited by the thermal diffusion of sputtered ZnO:Mn film. They show a textured structure with some preferred orientations. Our film phosphor shows, for the best photoluminescence (PL) brightness, a green PL brightness of about 20% of a commercial Zn 2 SiO 4 :Mn 2+ powder phosphor screen. The film shows a high transmittance of more than 10% at the red-color region. The excellence in PL brightness and transmittance can be explained in terms of the textured crystal growth with a continuous gradient of Zn 2 SiO 4 : Mn 2+ crystals.

  17. Structures and growth textures of Japanese twin boundaries in quartz

    Science.gov (United States)

    Momma, K.; Nagase, T.; Kudoh, Y.; Kuribayashi, T.

    2008-12-01

    Growth textures and atomic configurations of Japanese twin boundaries in quartz were studied by the observation of natural samples and by computational simulations. Samples used in this study are collected from Narushima, Nagasaki Prefecture, Japan. The samples were first polished, and then etched by hydrofluoric acid for several minutes. The etched figures were observed by phase-contrast reflection microscopy and scanning electron microscopy. From these observations, high concentration of Brazil twin lamellae is found near the composition plane of Japanese twin. Observations of cathode luminescence images reveal that the development of Brazil twin lamellae at {112×2} composition plane of Japanese twin is directly related to the preferential growth of Japanese twin along the composition plane. Atomic configurations at {112×2} composition planes of Japanese twin were simulated by using molecular dynamics simulations and the energy minimization method. The simulated structures proved that {112×2} or {1×1×22} composition planes are the only composition planes that do not introduce unsatisfied bonding between Si and O atoms. When the composition plane is different from these planes, some kind of defect structures, like dislocations, are inevitably introduced. In the case of Brazil twin, screw dislocations are also known to be incorporated where orientation of Brazil twin boundary changes from one orientation to another. On the other hand, in the case where Brazil twin boundaries intersect with {112×2} composition planes of Japanese twin, we found that structures are kept coherently without any unsatisfied bonding. This result means that {112×2} composition planes of Japanese twin are the crystallographic sites having more than one possible stacking structures. Observations in this study indicate that {112×2} composition plane of Japanese twin serves as a source of Brazil twin during the course of crystal growth.

  18. Radiation resisting features of pure quartz fiber

    International Nuclear Information System (INIS)

    Fujii, Takashi; Nagasawa, Yoshiya; Hoshi, Hiroshi; Tomon, Ryoichi; Ooki, Yoshimichi; Yahagi, Kichinosuke

    1985-01-01

    The control of the generation of color centers is essential for optical fibers used in radiation environment. Even pure quartz which is the best radiation resisting material is not exceptional also elucidarion of the mechanism of the generation of color center is necessary for the development of optical fiber with higher radiation resisting feature. Previously, it was assumed that color centers are distributed uniformly throughout cores. Determination of the distribution of color centers was attempted. Cores were etched with HF after γ-ray irradiation, and the changes of intensity of ESR signals of NBOHC and E'-center were determined. NBOHC were not found in circumferential part, and concentrated in the central part. In other words the tendency of distribution is diametral. Thus, the distribution of precursor is supposed to be affected by certain external cause and the generation of NBOHC was depressed in circumferential area. The distribution of E'-center of high OH sample showed similar tendency and high in the center. Where as the distribution in low OH sample was uniform. The external cause is supposed to be hydrogen derived from silicone clad and silicone buffer. Two kind of precursor is suspected for the explanation of the difference of the E'-center in high OH sample and low OH sample. (Ishimitsu, A.)

  19. Aberrant thermoluminescence dates obtained from primary volcanic quartz

    International Nuclear Information System (INIS)

    Guerin, Gilles; Samper, Agnes

    2007-01-01

    This study deals with the dating by thermoluminescence (TL) of quartz from six volcanic formations of the Saint Lucia Island (Lesser Antilles Arc). Quartz microcrystals up to one millimetre in size were extracted from dacites and pumice flows and prepared in a way similar to the well-known inclusion technique. The TL properties of these quartz were used to estimate apparent palaeodoses using the multi-aliquot protocol. The quartz TL was studied in three different spectral domains: red, green and ultraviolet/blue. The calculated annual dose-rates yielded a set of 18 age-estimates. For some samples complementary dates were obtained using high temperature TL (HTTL) of plagioclase feldspars. These latter dates combined with previously determined radiocarbon and unspiked K-Ar dates were used to explore the validity of ages computed from the TL of quartz. Individual values for quartz appear to be scattered and do not match ages deduced from 14 C, unspiked K-Ar or HTTL on plagioclase dates. These results indicate that when conventional TL methodologies derived from the inclusion method are applied to volcanic quartz major dating problems are to be expected

  20. Aberrant thermoluminescence dates obtained from primary volcanic quartz

    Energy Technology Data Exchange (ETDEWEB)

    Guerin, Gilles [Laboratoire des Sciences du Climat et de l' Environnement, CEA-CNRS, avenue de la Terrasse, 91191 Gif-sur-Yvette (France)], E-mail: gilles.guerin@u-psud.fr; Samper, Agnes [Laboratoire de geochronologie multitechnique (UPS-IPGP), Universite de Paris-Sud Orsay, 91405 Orsay Cedex (France)

    2007-10-15

    This study deals with the dating by thermoluminescence (TL) of quartz from six volcanic formations of the Saint Lucia Island (Lesser Antilles Arc). Quartz microcrystals up to one millimetre in size were extracted from dacites and pumice flows and prepared in a way similar to the well-known inclusion technique. The TL properties of these quartz were used to estimate apparent palaeodoses using the multi-aliquot protocol. The quartz TL was studied in three different spectral domains: red, green and ultraviolet/blue. The calculated annual dose-rates yielded a set of 18 age-estimates. For some samples complementary dates were obtained using high temperature TL (HTTL) of plagioclase feldspars. These latter dates combined with previously determined radiocarbon and unspiked K-Ar dates were used to explore the validity of ages computed from the TL of quartz. Individual values for quartz appear to be scattered and do not match ages deduced from {sup 14}C, unspiked K-Ar or HTTL on plagioclase dates. These results indicate that when conventional TL methodologies derived from the inclusion method are applied to volcanic quartz major dating problems are to be expected.

  1. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results. © 2009 American Institute of Physics.

  2. Impedance-matched Marx generators

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2017-04-01

    Full Text Available We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs. The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with LC time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22-Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19-Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  3. Impedance-matched Marx generators

    Science.gov (United States)

    Stygar, W. A.; LeChien, K. R.; Mazarakis, M. G.; Savage, M. E.; Stoltzfus, B. S.; Austin, K. N.; Breden, E. W.; Cuneo, M. E.; Hutsel, B. T.; Lewis, S. A.; McKee, G. R.; Moore, J. K.; Mulville, T. D.; Muron, D. J.; Reisman, D. B.; Sceiford, M. E.; Wisher, M. L.

    2017-04-01

    We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs). The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with L C time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22 -Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19 -Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  4. In-homogeneity in the pre-dose sensitization of the 110 °C TL peak in various quartz samples: The influence of annealing

    International Nuclear Information System (INIS)

    Polymeris, George S.; Oniya, Ebenezer O.; Jibiri, Nnamdi N.; Tsirliganis, Nestor C.; Kitis, George

    2012-01-01

    The pre-dose sensitization effect of the 110 °C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot – to – aliquot scatter of the pre-dose sensitization of the 110 °C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired “as is” samples as well as to samples annealed at 900 °C for 1 h following cooling to room temperature in air. The results showed that in the case of “as is” quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 °C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.

  5. In-homogeneity in the pre-dose sensitization of the 110 Degree-Sign C TL peak in various quartz samples: The influence of annealing

    Energy Technology Data Exchange (ETDEWEB)

    Polymeris, George S., E-mail: polymers@auth.gr [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); ISIK University, Faculty of Science and Arts, Physics Department, Sile 34980, Istanbul (Turkey); Oniya, Ebenezer O. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); Physics and Electronics Department, Adekunle Ajasin University, PMB 01 Akungba Akoko (Nigeria); Jibiri, Nnamdi N. [Department of Physics, University of Ibadan, Ibadan (Nigeria); Tsirliganis, Nestor C. [Laboratory of Radiation Applications and Archaeological Dating, Department of Archaeometry and Physicochemical Measurements, Cultural and Educational Technology Institute, Athena, Research and Innovation Center in Information, Communication and Knowledge Technologies, Tsimiski 58, GR-67100 Xanthi (Greece); Kitis, George [Aristotle University of Thessaloniki, Nuclear Physics Laboratory, 54124 Thessaloniki (Greece)

    2012-03-01

    The pre-dose sensitization effect of the 110 Degree-Sign C TL glow-peak of quartz is a basic tool in thermoluminescence and optically stimulated luminescence dating and retrospective dosimetry. In the present work, a homogeneity study was performed on pre-dose sensitization in grains obtained from large quartz crystals samples collected from 10 different origins. The aliquot - to - aliquot scatter of the pre-dose sensitization of the 110 Degree-Sign C TL peak within each quartz crystal was monitored. The influence of the annealing on this scattering was also studied. Therefore, the investigation was applied to the un-fired 'as is' samples as well as to samples annealed at 900 Degree-Sign C for 1 h following cooling to room temperature in air. The results showed that in the case of 'as is' quartz the sensitization effect vary strongly within each aliquot of the same quartz sample. This strong variation is removed by both the high temperature annealing as well as heating up to 500 Degree-Sign C, involved in the TL measurements. These results are generally discussed in the framework of existing models and applications of the effect.

  6. Electrical impedance tomography: topology optimization

    International Nuclear Information System (INIS)

    Miranda, Lenine Campos

    2013-01-01

    The Electrical Impedance Tomography (EIT) is a study of body parts who use electric current. Is studied through computers resistance or conductivity of these parts, producing an image used for medical diagnosis. A body is wrapped in a blanket placed with small electrodes and receivers of electric current, potential difference. Based on data obtained from a series of measurements at the electrodes, one by one, sending and receiving, you can perform a numerical phantom, where each 'voxel' of the image formed computationally represents the impedance of biological tissue. In Brazil, studies on electrical impedance tomography (EIT) has not yet started. Such equipment are measured tensions - potential difference - between each electrode / sensor one by one, as a way to Simple Combinatorial Analysis. The sequence and the way it is measured strains are in the final image quality. Finite Element Method Interactive, whose algorithm is based on Dialectical Method. We use an initial function with the objective of maximizing the data quantitatively, for better qualitative analysis. Topology Optimization methods are used to improve the image reconstruction. Currently the study is quite primitive related to the theory that shows how to power the new science studied. The high quality images requires a difficulty in obtaining. This work is not intended for detailed for analysis in any tissue or organ specific, but in general terms. And the formation of the 2D image. 3D need a reconstructor to part. (author)

  7. Cascaded impedance networks for NPC inverter

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    they are subject to the renewable sources. To date, three distinct types of impedance networks can be summarized for implementing a hybrid source impedance network, which can in principle be combined and cascaded before connected to a NPC inverter by proposed two ways. The resulting cascaded impedance network NPC...

  8. Impedance analysis of acupuncture points and pathways

    International Nuclear Information System (INIS)

    Teplan, Michal; Kukucka, Marek; Ondrejkovicová, Alena

    2011-01-01

    Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.

  9. Journal bearing impedance descriptions for rotordynamic applications

    NARCIS (Netherlands)

    Childs, D.W.; Moes, H.; Leeuwen, van H.J.

    1977-01-01

    Bearing impedance vectors are introduced for plain journal bearings which define the bearing reaction force components as a function of the bearing motion. Impedance descriptions are developed directly for the approximate Ocvirk (short) and Sommerfeld (long) bearing solutions. The impedance vector

  10. Quartz-coesite-stishovite relations in shocked metaquartzites from the Vredefort impact structure, South Africa

    Science.gov (United States)

    Spray, John G.; Boonsue, Suporn

    2018-01-01

    Coesite and stishovite are developed in shock veins within metaquartzites beyond a radius of 30 km from the center of the 2.02 Ga Vredefort impact structure. This work focuses on deploying analytical field emission scanning electron microscopy, electron backscattered diffraction, and Raman spectrometry to better understand the temporal and spatial relations of these silica polymorphs. α-Quartz in the host metaquartzites, away from shock veins, exhibits planar features, Brazil twins, and decorated planar deformation features, indicating a primary (bulk) shock loading of >5 < 35 GPa. Within the shock veins, coesite forms anhedral grains, ranging in size from 0.5 to 4 μm, with an average of 1.25 μm. It occurs in clasts, where it displays a distinct jigsaw texture, indicative of partial reversion to a less dense SiO2 phase, now represented by microcrystalline quartz. It is also developed in the matrix of the shock veins, where it is typically of smaller size (<1 μm). Stishovite occurs as euhedral acicular crystals, typically <0.5 μm wide and up to 15 μm in length, associated with clast-matrix or shock vein margin-matrix interfaces. In this context, the needles occur as radiating or subparallel clusters, which grow into/over both coesite and what is now microcrystalline quartz. Stishovite also occurs as more blebby, subhedral to anhedral grains in the vein matrix (typically <1 μm). We propose a model for the evolution of the veins (1) precursory frictional melting in a microfault ( 1 mm wide) generates a molten matrix containing quartz clasts. This is followed by (2) arrival of the main shock front, which shocks to 35 GPa. This generates coesite in the clasts and in the matrix. (3) On initial shock release, the coesite partly reverts to a less dense SiO2 phase, which is now represented by microcrystalline quartz. (4) With continued release, stishovite forms euhedral needle clusters at solid-liquid interfaces and as anhedral crystals in the matrix. (5) With

  11. Quartz-Enhanced Photoacoustic Spectroscopy Sensor with a Small-Gap Quartz Tuning Fork

    Directory of Open Access Journals (Sweden)

    Yu-Fei Ma

    2018-06-01

    Full Text Available A highly sensitive quartz-enhanced photoacoustic spectroscopy (QEPAS sensor based on a custom quartz tuning fork (QTF with a small-gap of 200 μm was demonstrated. With the help of the finite element modeling (FEM simulation software COMSOL, the change tendency of the QEPAS signal under the influence of the laser beam vertical position and the length of the micro-resonator (mR were calculated theoretically. Water vapor (H2O was selected as the target analyte. The experimental results agreed well with those of the simulation, which verified the correctness of the theoretical model. An 11-fold signal enhancement was achieved with the addition of an mR with an optimal length of 5 mm in comparison to the bare QTF. Finally, the H2O-QEPAS sensor, which was based on a small-gap QTF, achieved a minimum detection limit (MDL of 1.3 ppm, indicating an improvement of the sensor performance when compared to the standard QTF that has a gap of 300 μm.

  12. Luminescence sensitivity changes in quartz as a result of annealing

    DEFF Research Database (Denmark)

    Bøtter-Jensen, L.; Agersnap Larsen, N.; Mejdahl, V.

    1995-01-01

    archaeological samples show very different OSL sensitivities. In this paper we report on studies of the effect of high temperature annealing on the OSL and phototransferred TL (PTTL) signals from sedimentary and synthetic quartz. A dramatic enhancement of both OSL and PTTL sensitivity was found especially...... in the temperature range 500-800 degrees C. Computer simulations of the possible effects are shown to produce data that agree in all essential details with the experimental observations. It is further demonstrated that the enhanced OSL sensitivity as a function of annealing temperature is not a pre-dose effect....... of magnitude less per unit radiation than that for heated material. The reason these temperature-induced sensitivity changes occur in quartz is presently not well understood. This phenomenon is also seen in the related area of luminescence dating in which sedimentary quartz and quartz from heated...

  13. Structure optimization and simulation analysis of the quartz micromachined gyroscope

    Directory of Open Access Journals (Sweden)

    Xuezhong Wu

    2014-02-01

    Full Text Available Structure optimization and simulation analysis of the quartz micromachined gyroscope are reported in this paper. The relationships between the structure parameters and the frequencies of work mode were analysed by finite element analysis. The structure parameters of the quartz micromachined gyroscope were optimized to reduce the difference between the frequencies of the drive mode and the sense mode. The simulation results were proved by testing the prototype gyroscope, which was fabricated by micro-electromechanical systems (MEMS technology. Therefore, the frequencies of the drive mode and the sense mode can match each other by the structure optimization and simulation analysis of the quartz micromachined gyroscope, which is helpful in the design of the high sensitivity quartz micromachined gyroscope.

  14. ESR signals in quartz for the studies of earth surface processes

    Science.gov (United States)

    Toyoda, S.; Shimada, A., , Dr; Takada, M.

    2017-12-01

    Various ESR (electron spin resonance) signals are observed in quartz. As they are formed by natural radiation, the signals are useful in dating of geological events, such as volcanic eruption, faulting and sedimentation. It was also found that those paramagnetic defects can be fingerprints of sediments, to be used for studies in sediment provenance. The signal of the E1' center, unpaired electron at an oxygen vacancy, was first used for such studies. A method was proposed to estimate the number of the precursors (oxygen vacancies) from the E1' center intensity. The number of oxygen vacancies in quartz was found to have positive correlation with the crystallization age. Using this feature, studies were quite successful in aeolian dust. It was shown that the sources of aeolian dust deposited in northern part of Japanese Islands were different between in MIS1 and MIS 2. In combination with crystallinity index, the contributions of the dust components from three origins were quantitatively obtained. After these, the provenance studies on river sediments have started where the impurity centers in quartz were employed, which are the Al center, the Ti centers, and the Ge centers. Sediments of Kizu River, Mie to Nara prefectures in Central Japan are most extensively studied. Firstly, it was shown that each of possible sources of granitic quartz around the reaches has respective characteristics in the number of oxygen vacancies and the signal intensities of impurity centers. Secondary, by the artificial mixing experiments, the impurity signal intensities have the values consistent with the mixing ratio of the two samples of quartz with different intensities. At river junctions, the mixing ratios were calculated from the ESR signals. At some locations, the mixing ratio values obtained from one signal were consistent with the ones from another signal while at some locations they were not. The latter inconsistent results would indicate that the river sediments are

  15. Microbially induced separation of quartz from calcite using Saccharomyces cerevisiae.

    Science.gov (United States)

    Padukone, S Usha; Natarajan, K A

    2011-11-01

    Cells of Saccharomyces cerevisiae and their metabolites were successfully utilized to achieve selective separation of quartz and calcite through microbially induced flotation and flocculation. S. cerevisiae was adapted to calcite and quartz minerals. Adsorption studies and electrokinetic investigations were carried out to understand the changes in the surface chemistry of yeast cells and the minerals after mutual interaction. Possible mechanisms in microbially induced flotation and flocculation are outlined. Copyright © 2011 Elsevier B.V. All rights reserved.

  16. Study of thermoluminescence response of purple to violet amethyst quartz from Balikesir, Turkey

    International Nuclear Information System (INIS)

    Nur, N.; Yeğingil, Z.; Topaksu, M.; Kurt, K.; Doğan, T.; Sarıgül, N.; Yüksel, M.; Altunal, V.; Özdemir, A.; Güçkan, V.; Günay, I.

    2015-01-01

    Highlights: • We reported on dosimetric characterisation of natural amethyst quartz specimens from Turkey, using TL technique. • The thermoluminescence characterisation tests were performed under the beta radiation exposure. • The IT peaks ∼230 °C show superlinear dose response behavior (g(D) > 1) between 1 Gy and 5 kGy. The HT peaks ∼300 °C show linear behavior (g(D) = 1) at low dose levels (1 < D < 20 Gy) and superlinearity (g(D) > 1) between 20 Gy < D < 2 kGy. • Deviations were determined for recycling measurements for various dose values of 0.1, 0.5, 0.8 and 1 kGy. • Amethyst quartz has great potential to be investigated for dosimetry purpose. - Abstract: In thermoluminescence (TL) dosimetry, the phosphor amethyst quartz as a thermoluminescent, appears to be one of the materials arousing the highest interest. In this study the dosimetric characteristics of natural amethyst quartz crystals collected from Balikesir–Dursunbey (Turkey) were investigated for the purpose of determination of the general properties that phosphors should have in order to be useful for thermoluminescence dosimetry. The natural thermoluminescence was drained by annealing the powder samples at 450 °C for 1.5 h. The effects of high temperature annealing, dose response curves, glow curves after a postirradiation annealing, reusability of the samples and storage of trapped electrons in dark at room temperature were clarified through irradiating the samples with the desired exposures by 90 Sr/ 90 Y beta particles. Isothermal annealing before and after irradiation was found to have a definite effect upon the TL glow curve of amethyst crystal powder. The same sample varied in sensitivity depending upon its previous thermal and radiation history. The peak heights of the glow peaks were examined with respect to dose response at dose levels between 1 Gy and 5 kGy. The intermediate temperature (IT) and high temperature (HT) peaks of 230 °C and 300 °C, respectively, exhibit dose

  17. Study of thermoluminescence response of purple to violet amethyst quartz from Balikesir, Turkey

    Energy Technology Data Exchange (ETDEWEB)

    Nur, N., E-mail: nnur@adiyaman.edu.tr [Adiyaman University, Engineering Faculty, Department of Electrical and Electronic Engineering, 02040 Adiyaman (Turkey); Yeğingil, Z.; Topaksu, M. [Cukurova University, Art and Sciences Faculty, Physics Department, 01330 Adana (Turkey); Kurt, K. [University of Mersin, Science and Art Faculty, Physics Department, 33343 Mersin (Turkey); Doğan, T. [Cukurova University, Vocational School of Imamoglu, Department of Technical Programs, 01700 Adana (Turkey); Sarıgül, N. [Institute of Nuclear Science, Hacettepe University, 06532 Ankara (Turkey); Yüksel, M.; Altunal, V.; Özdemir, A.; Güçkan, V. [Cukurova University, Art and Sciences Faculty, Physics Department, 01330 Adana (Turkey); Günay, I. [Cukurova University, Medicine Faculty, Biophysics Department, Adana (Turkey)

    2015-09-01

    Highlights: • We reported on dosimetric characterisation of natural amethyst quartz specimens from Turkey, using TL technique. • The thermoluminescence characterisation tests were performed under the beta radiation exposure. • The IT peaks ∼230 °C show superlinear dose response behavior (g(D) > 1) between 1 Gy and 5 kGy. The HT peaks ∼300 °C show linear behavior (g(D) = 1) at low dose levels (1 < D < 20 Gy) and superlinearity (g(D) > 1) between 20 Gy < D < 2 kGy. • Deviations were determined for recycling measurements for various dose values of 0.1, 0.5, 0.8 and 1 kGy. • Amethyst quartz has great potential to be investigated for dosimetry purpose. - Abstract: In thermoluminescence (TL) dosimetry, the phosphor amethyst quartz as a thermoluminescent, appears to be one of the materials arousing the highest interest. In this study the dosimetric characteristics of natural amethyst quartz crystals collected from Balikesir–Dursunbey (Turkey) were investigated for the purpose of determination of the general properties that phosphors should have in order to be useful for thermoluminescence dosimetry. The natural thermoluminescence was drained by annealing the powder samples at 450 °C for 1.5 h. The effects of high temperature annealing, dose response curves, glow curves after a postirradiation annealing, reusability of the samples and storage of trapped electrons in dark at room temperature were clarified through irradiating the samples with the desired exposures by {sup 90}Sr/{sup 90}Y beta particles. Isothermal annealing before and after irradiation was found to have a definite effect upon the TL glow curve of amethyst crystal powder. The same sample varied in sensitivity depending upon its previous thermal and radiation history. The peak heights of the glow peaks were examined with respect to dose response at dose levels between 1 Gy and 5 kGy. The intermediate temperature (IT) and high temperature (HT) peaks of 230 °C and 300 °C, respectively

  18. Observations involving broadband impedance modelling

    International Nuclear Information System (INIS)

    Berg, J.S.

    1995-08-01

    Results for single- and multi-bunch instabilities can be significantly affected by the precise model that is used for the broadband impendance. This paper discusses three aspects of broadband impendance modeling. The first is an observation of the effect that a seemingly minor change in an impedance model has on the single-bunch mode coupling threshold. The second is a successful attempt to construct a model for the high-frequency tails of an r.f cavity. The last is a discussion of requirements for the mathematical form of an impendance which follow from the general properties of impendances

  19. Lithium ion mobility in lithium phosphidosilicates: Crystal structure, {sup 7}Li, {sup 29}Si, and {sup 31}P MAS NMR spectroscopy, and impedance spectroscopy of Li{sub 8}SiP{sub 4} and Li{sub 2}SiP{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Toffoletti, Lorenzo; Landesfeind, Johannes; Klein, Wilhelm; Gasteiger, Hubert A.; Faessler, Thomas F. [Department of Chemistry, Technische Universitaet Muenchen, Lichtenbergstrasse 4, 85747, Garching bei Muenchen (Germany); Kirchhain, Holger; Wuellen, Leo van [Department of Physics, University of Augsburg, Universitaetsstrasse 1, 86159, Augsburg (Germany)

    2016-12-05

    The need to improve electrodes and Li-ion conducting materials for rechargeable all-solid-state batteries has drawn enhanced attention to the investigation of lithium-rich compounds. The study of the ternary system Li-Si-P revealed a series of new compounds, two of which, Li{sub 8}SiP{sub 4} and Li{sub 2}SiP{sub 2}, are presented. Both phases represent members of a new family of Li ion conductors that display Li ion conductivity in the range from 1.15(7) x 10{sup -6} Scm{sup -1} at 0 C to 1.2(2) x 10{sup -4} Scm{sup -1} at 75 C (Li{sub 8}SiP{sub 4}) and from 6.1(7) x 10{sup -8} Scm{sup -1} at 0 C to 6(1) x 10{sup -6} Scm{sup -1} at 75 C (Li{sub 2}SiP{sub 2}), as determined by impedance measurements. Temperature-dependent solid-state {sup 7}Li NMR spectroscopy revealed low activation energies of about 36 kJ mol{sup -1} for Li{sub 8}SiP{sub 4} and about 47 kJ mol{sup -1} for Li{sub 2}SiP{sub 2}. Both compounds were structurally characterized by X-ray diffraction analysis (single crystal and powder methods) and by {sup 7}Li, {sup 29}Si, and {sup 31}P MAS NMR spectroscopy. Both phases consist of tetrahedral SiP{sub 4} anions and Li counterions. Li{sub 8}SiP{sub 4} contains isolated SiP{sub 4} units surrounded by Li atoms, while Li{sub 2}SiP{sub 2} comprises a three-dimensional network based on corner-sharing SiP{sub 4} tetrahedra, with the Li ions located in cavities and channels. (copyright 2016 Wiley-VCH Verlag GmbH and Co. KGaA, Weinheim)

  20. Stones of Light: The Use of Crystals in Maya Divination

    DEFF Research Database (Denmark)

    McGraw, John J.

    2016-01-01

    In this chapter, I aim to bridge the rewarding archaeological contributions from the earlier part of this volume to ethnographic work performed among contemporary Mayas, particularly as informed by ritual specialists. In considering the ritual use of quartz crystals by living Mayas we may gain...... of functional analysis that situate archaeological and ethnographic data without projecting a particularism onto Maya contexts that may be inappropriate given the local epistemologies. Finally, I draw from cognitive science and religious studies to present a theory regarding the popularity and importance...... of quartz crystals in ritual activity, not only among the Maya, but worldwide. It is hoped that the analyses presented not only clarify ideas regarding quartz crystals in divination, but more broadly address the nature and importance of scrying in Maya religion....

  1. Deformation behavior of migmatites: insights from microstructural analysis of a garnet-sillimanite-mullite-quartz-feldspar-bearing anatectic migmatite at Rampura-Agucha, Aravalli-Delhi Fold Belt, NW India

    Science.gov (United States)

    Prakash, Abhishek; Piazolo, Sandra; Saha, Lopamudra; Bhattacharya, Abhijit; Pal, Durgesh Kumar; Sarkar, Saheli

    2018-03-01

    In the present study we investigate the microstructural development in mullite, quartz and garnet in an anatectic migmatite hosted within a Grenvillian-age shear zone in the Aravalli-Delhi Fold Belt. The migmatite exhibits three main deformation structures and fabrics (S1, S2, S3). Elongated garnet porphyroblasts are aligned parallel to the metatexite S2 layers and contain crenulation hinges defined by biotite-sillimanite-mullite-quartz (with S1 axial planar foliation). Microstructural evidence and phase equilibrium relations establish the garnet as a peritectic phase of incongruent melting by breakdown of biotite, sillimanite ± mullite and quartz at peak P-T of 8 kbar, 730 °C along a tight-loop, clockwise P-T path. Monazite dating establishes that the partial melting occurred between 1000 and 870 Ma. The absence of subgrains and systematic crystal lattice distortions in these garnets despite their elongation suggests growth pseudomorphing pre-existing 3-D networks of S1 biotite aggregates rather than high-temperature crystal plastic deformation which is noted in the S1 quartz grains that exhibit strong crystallographic preferred orientation (CPO), undulatory extinction and subgrains. Mode-I fractures in these garnet porphyroblasts induced by high melt pressure during late stage of partial melt crystallization are filled by retrograde biotite-sillimanite. Weak CPO and non-systematic crystal lattice distortions in the coarse quartz grains within the S2 leucosome domains indicate these crystallized during melt solidification without later crystal plastic deformation overprint. In the later stages of deformation (D3), strain was mostly accommodated in the mullite-biotite-sillimanite-rich restite domains forming S3 which warps around garnet and leucosome domains; consequently, fine-grained S3 quartz does not exhibit strong CPOs.

  2. Crystallization Stages of the Bishop Tuff Magma Body Recorded in Crystal Textures in Pumice Clasts

    Energy Technology Data Exchange (ETDEWEB)

    Pamukcu, Ayla; Gualda, Guilherme A.R.; Anderson, Jr. , Alfred T. (Vanderbilt); (UC)

    2012-07-25

    The Bishop Tuff is a giant silicic ignimbrite erupted at 0.76 Ma in eastern California, USA. Five pumice clasts from the late-erupted Bishop Tuff (Aeolian Buttes) were studied in an effort to better understand the pre- and syn-eruptive history of the Bishop magma body and place constraints on the timescales of its existence. This study complements and expands on a previous study that focused on early-erupted Bishop Tuff pumice clasts. Bulk densities of pumice clasts were measured using an immersion method, and phenocryst crystal contents were determined using a sieving and winnowing procedure. X-ray tomography was used to obtain qualitative and quantitative textural information, particularly crystal size distributions (CSDs). We have determined CSDs for crystals ranging in size from {approx}10 to {approx}1000 {micro}m for three groups of mineral phases: magnetite ({+-}ilmenite), pyroxene + biotite, quartz + feldspar. Similar to early-erupted pumice, late-erupted pumice bulk density and crystal contents are positively correlated, and comparison of crystal fraction vs size trends suggests that the proportion of large crystals is the primary control on crystallinity. Porosity is negatively correlated with crystal content, which is difficult to reconcile with closed-system crystallization. Magnetite and pyroxene + biotite size distributions are fractal in nature, often attributed to fragmentation; however, crystals are mostly whole and euhedral, such that an alternative mechanism is necessary to explain these distributions. Quartz + feldspar size distributions are kinked, with a shallow-sloped log-linear section describing large crystals (> 140 {micro}m) and a steep-sloped log-linear section describing small crystals (< 140 {micro}m). We interpret these two crystal populations as resulting from a shift in crystallization regime. We suggest that the shallow-sloped section describes a pre-eruptive quartz + feldspar growth-dominated regime, whereas the steep

  3. Spheromak Impedance and Current Amplification

    International Nuclear Information System (INIS)

    Fowler, T K; Hua, D D; Stallard, B W

    2002-01-01

    It is shown that high current amplification can be achieved only by injecting helicity on the timescale for reconnection, τ REC , which determines the effective impedance of the spheromak. An approximate equation for current amplification is: dI TOR 2 /dt ∼ I 2 /τ REC - I TOR 2 /τ closed where I is the gun current, I TOR is the spheromak toroidal current and τ CLOSED is the ohmic decay time of the spheromak. Achieving high current amplification, I TOR >> I, requires τ REC CLOSED . For resistive reconnection, this requires reconnection in a cold zone feeding helicity into a hot zone. Here we propose an impedance model based on these ideas in a form that can be implemented in the Corsica-based helicity transport code. The most important feature of the model is the possibility that τ REC actually increases as the spheromak temperature increases, perhaps accounting for the ''voltage sag'' observed in some experiments, and a tendency toward a constant ratio of field to current, B ∝ I, or I TOR ∼ I. Program implications are discussed

  4. The problem of dating quartz 2: Synchrotron generated X-ray excited optical luminescence (XEOL) from quartz

    International Nuclear Information System (INIS)

    King, G.E.; Finch, A.A.; Robinson, R.A.J.; Taylor, R.P.; Mosselmans, J.F.W.

    2011-01-01

    The luminescence emission of quartz is used in optically stimulated luminescence dating (OSL), however the precise origins of the emission are unclear. A suite of quartz samples were analysed using X-ray excited optical luminescence (XEOL). Radiation dose effects were observed whereby the UV emissions (3.8 and 3.4 eV) were depleted to the benefit of the red emission (1.9-2.0 eV). Samples were excited at ∼7 keV. Understanding why some quartz emit light more brightly than others will increase the efficiency and precision of OSL analyses. - Highlights: → The X-ray excited optical luminescence (XEOL) emission of quartz is explored. → The XEOL of quartz of different provenances varies. → Radiation dosing causes UV emissions to deplete to the benefit of red emissions. → The 3.8 and 3.4 eV emissions deplete at the same rate. → The quartz luminescence emission exhibits anisotropic effects.

  5. Some experiments on the high-low transition of quartz; Recherches experimentales sur une transformation du quartz

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, G [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-12-15

    First section. - We expose on the one hand a theory of specific heat, thermal expansion and variations of elastic constants as functions of temperature, which is applicable only in the absence of transformation phenomena affecting symmetry or periodicity of the crystal lattice. On the other hand, we discuss some theories relative to the phenomena which accompany phase transformations. Second section. - We have gathered together numerical results concerning elastic, piezoelectric and optical properties of quartz. Some have been collected from the literature, other have been obtained in our laboratories with the help of experimental methods which we describe. As a result, we are able to present a complete picture of the evolution of these constants in a large temperature range containing the critical temperature of 574 deg. C at which these constants exhibit discontinuities. New phenomena have been observed, in the course of these studies. Third section. - We show that the evolution of the two piezoelectric and elastic constants which cancel out in the high temperature form is described by the same function. With the inclusion of one other function, it is possible to explain quantitatively the behaviour in the transformation range of all the other constants under study. With the help of crystallographic considerations and of hypotheses concerning the nature of the transformation entropy, we finally try to account for the experimental values of these two functions. (author) [French] Dans une premiere partie, nous exposons d'une part une theorie de la chaleur specifique, de la dilatation thermique et des variations des constantes elastiques des solides avec la temperature qui n'est valable qu'en l'absence de phenomenes de transformation affectant la symetrie ou la periodicite de l'edifice cristallin, et nous rappelons d'autre part quelques theories relatives aux phenomenes qui accompagnent les changements de phase. Dans une seconde partie, nous avons rassemble un grand

  6. Some experiments on the high-low transition of quartz; Recherches experimentales sur une transformation du quartz

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, G. [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1959-12-15

    First section. - We expose on the one hand a theory of specific heat, thermal expansion and variations of elastic constants as functions of temperature, which is applicable only in the absence of transformation phenomena affecting symmetry or periodicity of the crystal lattice. On the other hand, we discuss some theories relative to the phenomena which accompany phase transformations. Second section. - We have gathered together numerical results concerning elastic, piezoelectric and optical properties of quartz. Some have been collected from the literature, other have been obtained in our laboratories with the help of experimental methods which we describe. As a result, we are able to present a complete picture of the evolution of these constants in a large temperature range containing the critical temperature of 574 deg. C at which these constants exhibit discontinuities. New phenomena have been observed, in the course of these studies. Third section. - We show that the evolution of the two piezoelectric and elastic constants which cancel out in the high temperature form is described by the same function. With the inclusion of one other function, it is possible to explain quantitatively the behaviour in the transformation range of all the other constants under study. With the help of crystallographic considerations and of hypotheses concerning the nature of the transformation entropy, we finally try to account for the experimental values of these two functions. (author) [French] Dans une premiere partie, nous exposons d'une part une theorie de la chaleur specifique, de la dilatation thermique et des variations des constantes elastiques des solides avec la temperature qui n'est valable qu'en l'absence de phenomenes de transformation affectant la symetrie ou la periodicite de l'edifice cristallin, et nous rappelons d'autre part quelques theories relatives aux phenomenes qui accompagnent les changements de phase. Dans une seconde partie

  7. Pressure-induced drastic collapse of a high oxygen coordination shell in quartz-like α-GeO2

    International Nuclear Information System (INIS)

    Dong, Juncai; Zhang, Xiaoli; Wu, Ziyu; Chen, Dongliang; Zhang, Qian; Wu, Ye; Wu, Xiang

    2014-01-01

    With the combination of a single crystal diamond anvil cell and a polycapillary half-lens, the local structural evolution around germanium in tetrahedrally networked quartz-like α-GeO 2 has been investigated using extended x-ray absorption fine structure spectroscopy of up to 14 GPa by multiple-scattering analysis method. While the first shell Ge–O bond distances show a slight contraction with increasing pressure, the third shell Ge–O bond distances are found to decrease dramatically. The sluggish lengthening of the first shell Ge–O bond distances, initiated by coordination increase from fourfold to sixfold, occurs in the 7–14 GPa range just when the third shell Ge–O bond distances fall in the region of the second shell Ge–Ge bond distances. Moreover, these features are accompanied by the closing of intertetrahedral Ge–O–Ge angles and the opening of two intratetrahedral O–Ge–O angles, whose topological configuration surprisingly exhibits a helical chirality along the c axis that is opposite to the double helices of the corner-linked GeO 4 tetrahedra. These results suggest that the high-pressure phase transitions in quartz and quartz-like materials could be associated with a structural instability that is driven by the drastic collapse of the next-nearest-neighbour anion shell, which is consistent with the emergence of high-symmetry anion sublattice. Our findings provide crucial insights into the densification mechanisms of quartz-like oxides, which would have broad implications for our understanding of the metastability of various post-quartz crystalline phases and pressure-induced amorphization. (paper)

  8. Diagenetic Quartz Morphologies and Zeolite formation

    DEFF Research Database (Denmark)

    Kazerouni, Afsoon Moatari; Hansen, Rikke Weibel; Friis, Henrik

    the Siri Canyon wells.  Volcanic lithoclasts are strongly altered and associated with diagenetic opal/ microquartz coatings and zeolite.  Zeolite crystals formed simultaneously with opal and prior to microquartz but dissolved with increased burial depth.  The dissolution of zeolite followed two steps...... in samples where no volcanic ash is demonstrated; it seems that a rapid supply of dissolved silica from dissolution of siliceous fossils was the main reason for the early co-precipitation of opal and zeolite. There are two important sources for Si: 1) Biogenic opal from diatoms or radiolarians, which...... are abundant in some of associated shales; and 2) volcanic ash. The dissolution of biogenic silica may result in a rapid release of silica thereby promoting the formation of diagenetic opal/microquartz, but there may be a limited release of Al. A limited release of Al may result in precipitation of Si...

  9. Soil chemistry in lithologically diverse datasets: the quartz dilution effect

    Science.gov (United States)

    Bern, Carleton R.

    2009-01-01

    National- and continental-scale soil geochemical datasets are likely to move our understanding of broad soil geochemistry patterns forward significantly. Patterns of chemistry and mineralogy delineated from these datasets are strongly influenced by the composition of the soil parent material, which itself is largely a function of lithology and particle size sorting. Such controls present a challenge by obscuring subtler patterns arising from subsequent pedogenic processes. Here the effect of quartz concentration is examined in moist-climate soils from a pilot dataset of the North American Soil Geochemical Landscapes Project. Due to variable and high quartz contents (6.2–81.7 wt.%), and its residual and inert nature in soil, quartz is demonstrated to influence broad patterns in soil chemistry. A dilution effect is observed whereby concentrations of various elements are significantly and strongly negatively correlated with quartz. Quartz content drives artificial positive correlations between concentrations of some elements and obscures negative correlations between others. Unadjusted soil data show the highly mobile base cations Ca, Mg, and Na to be often strongly positively correlated with intermediately mobile Al or Fe, and generally uncorrelated with the relatively immobile high-field-strength elements (HFS) Ti and Nb. Both patterns are contrary to broad expectations for soils being weathered and leached. After transforming bulk soil chemistry to a quartz-free basis, the base cations are generally uncorrelated with Al and Fe, and negative correlations generally emerge with the HFS elements. Quartz-free element data may be a useful tool for elucidating patterns of weathering or parent-material chemistry in large soil datasets.

  10. Composition of coarse-grained magnetite from pegmatite dikes related to plutons of quartz monzonite in the Jabal Lababa area, Kingdom of Saudi Arabia

    Science.gov (United States)

    Overstreet, William C.; Mousa, Hassan; Matzko, John J.

    1985-01-01

    Crystals of magnetite as large as 30 mm long and 7 mm thick are locally present in quartz-rich zones of interior and exterior pegmatite dikes related to plutons of quartz monzonite in the Jabal Lababa area. Niobium, tin, and yttrium are strongly enriched in six specimens of magnetite from interior pegmatite dikes in a small pluton where these elements form geochemical anomalies in nonmagnetic heavy-mineral concentrates from wadi sediment. Less abundant anomalous elements in the magnetite are molybdenum, lead, and zirconium, which also tend to be present in anomalous amounts in the nonmagnetic concentrates from the niobium-bearing pluton. The most anomalous trace element in the magnetite is zinc, which is at least 10 times as abundant as it is in the quartz monzonite plutons or in the nonmagnetic concentrates. The capacity of magnetite to scavenge molybdenum, zinc, niobium, lead, tin, yttrium, and zirconium suggests the possible utility of magnetite as a geochemical sample medium.

  11. Pumping slots: impedances and power losses

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S [Maryland Univ., College Park, MD (United States). Dept. of Physics

    1996-08-01

    Contributions of pumping slots to the beam coupling impedances and power losses in a B-factory ring are considered. While their leading contribution is to the inductive impedance, for high-intensity machines with short bunches like e{sup +}e{sup -} B-factories the real part of the impedance and related loss factors are also important. Using an analytical approach we calculate the coupling impedances and loss factors due to slots in a ring with an arbitrary cross section of the vacuum chamber. Effects of the slot tilt on the beam impedance are also considered, and restrictions on the tilt angle are derived from limitations on the impedance increase. The power leakage through the slots is discussed briefly. The results are applied to the KEK B-factory. (author)

  12. Dielectric and impedance spectroscopic studies of neodymium gallate

    Energy Technology Data Exchange (ETDEWEB)

    Sakhya, Anup Pradhan, E-mail: npshakya31@gmail.com [Department of Physics, Bose Institute, 93/1 Acharya Prafulla Chandra Road, Kolkata 700009 (India); Dutta, Alo [Department of Condensed Matter Physics and Material Sciences, S. N. Bose National Centre for Basic Sciences, Block-JD, Sector-III, Salt Lake, Kolkata 700098 (India); Sinha, T.P. [Department of Physics, Bose Institute, 93/1 Acharya Prafulla Chandra Road, Kolkata 700009 (India)

    2016-05-01

    The AC electrical properties of a polycrystalline neodymium gallate, NdGaO{sub 3} (NGO), synthesized by the sol–gel method have been investigated by employing impedance spectroscopy in the frequency range from 42 Hz to 5 MHz and in the temperature range from 323 K to 593 K. The X-ray diffraction analysis shows that the compound crystallizes in the orthorhombic phase with Pbnm space group at room temperature. Two relaxation processes with different relaxation times are observed from the impedance as well as modulus spectroscopic measurements, which have been attributed to the grain and the grain boundary effects at different temperatures in NGO. The complex impedance data are analyzed by an electrical equivalent circuit consisting of a resistance and a constant phase element in parallel. It has been observed that the value of the capacitance and the resistance associated with the grain boundary is higher than those associated with the grain. The temperature dependent electrical conductivity shows the negative temperature coefficient of resistance. The frequency dependent conductivity spectra are found to follow the power law.

  13. First-principles simulation of Raman spectra and structural properties of quartz up to 5 GPa

    International Nuclear Information System (INIS)

    Liu Lei; Lv Chao-Jia; Yi Li; Liu Hong; Du Jian-Guo; Zhuang Chun-Qiang

    2015-01-01

    The crystal structure and Raman spectra of quartz are calculated by using first-principles method in a pressure range from 0 to 5 GPa. The results show that the lattice constants (a, c, and V) decrease with increasing pressure and the a-axis is more compressible than the c axis. The Si–O bond distance decreases with increasing pressure, which is in contrast to experimental results reported by Hazen et al. [Hazen R M, Finger L W, Hemley R J and Mao H K 1989 Solid State Communications 725 507–511], and Glinnemann et al. [Glinnemann J, King H E Jr, Schulz H, Hahn T, La Placa S J and Dacol F 1992 Z. Kristallogr. 198 177–212]. The most striking changes are of inter-tetrahedral O–O distances and Si–O–Si angles. The volume of the tetrahedron decreased by 0.9% (from 0 to 5 GPa), which suggests that it is relatively rigid. Vibrational models of the quartz modes are identified by visualizing the associated atomic motions. Raman vibrations are mainly controlled by the deformation of the tetrahedron and the changes in the Si–O–Si bonds. Vibrational directions and intensities of atoms in all Raman modes just show little deviations when pressure increases from 0 to 5 GPa. The pressure derivatives (dν i /dP) of the 12 Raman frequencies are obtained at 0 GPa–5 GPa. The calculated results show that first-principles methods can well describe the high-pressure structural properties and Raman spectra of quartz. The combination of first-principles simulations of the Raman frequencies of minerals and Raman spectroscopy experiments is a useful tool for exploring the stress conditions within the Earth. (paper)

  14. MVAC Submarine cable, impedance measurements and analysis

    DEFF Research Database (Denmark)

    Arentsen, Martin Trolle; Expethit, Adrian; Pedersen, Morten Virklund

    2017-01-01

    influence the losses. Secondly, cable parameters such as component impedances, positive-, zero-sequence impedances and losses are measured for varying currents and frequencies. Zero sequence is measured for two setups, one with armour grounded, and with armour open to match CIGREs formula assumption......-sequence impedance is found between the measurements and the CIGRÉ formulas. It is concluded that the formulas are not accurate for the specific cable under test....

  15. A compact broadband nonsynchronous noncommensurate impedance transformer

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Kim, Kseniya; Narenda, Kumar

    2012-01-01

    Nonsynchronous noncommensurate impedance transformers consist of a combination of high‐ and low‐impedance transmission lines. High‐impedance lines have narrow tracks in strip and microstrip technology, which allows for high flexibility and miniaturization of the layout in comparison...... to the traditional tapered line transformers. This flexibility of the broadband nonsynchronous noncommensurate impedance transformers is experimentally demonstrated in this article allowing the length reduction by almost three times. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:1832–1835, 2012; View...

  16. Surface complexation modelling: Experiments on sorption of nickel on quartz, goethite and kaolinite and preliminary tests on sorption of thorium on quartz

    Energy Technology Data Exchange (ETDEWEB)

    Puukko, E.; Hakanen, M. [Univ. of Helsinki (Finland). Dept. of Chemistry. Lab. of Radiochemistry

    1997-09-01

    The aim of the work was to study the sorption behaviour of Ni on quartz, goethite and kaolinite at different pH levels and in different electrolyte solutions of different strength. In addition preliminary experiments were made to study the sorption of thorium on quartz. The MUS quartz and Nilsiae quartz were analysed for MnO{sub 2} by neutron activation analysis (NAA) and the experimental results were modelled with the HYDRAQL computer model. 9 refs.

  17. On Impedance Spectroscopy of Supercapacitors

    Science.gov (United States)

    Uchaikin, V. V.; Sibatov, R. T.; Ambrozevich, A. S.

    2016-10-01

    Supercapacitors are often characterized by responses measured by methods of impedance spectroscopy. In the frequency domain these responses have the form of power-law functions or their linear combinations. The inverse Fourier transform leads to relaxation equations with integro-differential operators of fractional order under assumption that the frequency response is independent of the working voltage. To compare long-term relaxation kinetics predicted by these equations with the observed one, charging-discharging of supercapacitors (with nominal capacitances of 0.22, 0.47, and 1.0 F) have been studied by means of registration of the current response to a step voltage signal. It is established that the reaction of devices under study to variations of the charging regime disagrees with the model of a homogeneous linear response. It is demonstrated that relaxation is well described by a fractional stretched exponent.

  18. Electrical impedance tomography of electrolysis.

    Directory of Open Access Journals (Sweden)

    Arie Meir

    Full Text Available The primary goal of this study is to explore the hypothesis that changes in pH during electrolysis can be detected with Electrical Impedance Tomography (EIT. The study has relevance to real time control of minimally invasive surgery with electrolytic ablation. To investigate the hypothesis, we compare EIT reconstructed images to optical images acquired using pH-sensitive dyes embedded in a physiological saline agar gel phantom treated with electrolysis. We further demonstrate the biological relevance of our work using a bacterial E.Coli model, grown on the phantom. The results demonstrate the ability of EIT to image pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E.coli model. The results are promising, and invite further experimental explorations.

  19. Kinetics of the stress induced phase transition in quartz by real-time neutron scattering

    International Nuclear Information System (INIS)

    Gibhardt, H.; Eckold, G.; Guethoff, F.

    1999-01-01

    Complete text of publication follows. The stability regime of the incommensurate phase of quartz is influenced by uniaxial stress. Hence, the phase transition can be induced under isothermal conditions by the application of external mechanical forces. Using real-time neutron scattering the time evolution of structural changes is investigated id detail during stress variations. The time dependent behaviour of the satellite reflection is compared with that one of the fundamental Bragg reflection which - via primary extinction - gives information about the perfection of the crystal. On increasing stress the perfection of the lattice is destroyed immediately while the modulated structure is built up with a delay of about 1 s. Decreasing the stress leads to a reverse behaviour. Moreover, there is evidence that under periodical load residual non-relaxed strain fields survive leading to a different temperature dependence as compared to static conditions. This finding is compatible with pronounced hysteresis effects observed under cycling stress. It is argued that these residual strains are associated with non-relaxed topological 4-line defects, that drive the structural changes in quartz (1). (author)

  20. Salinity of the Archaean oceans from analysis of fluid inclusions in quartz

    Science.gov (United States)

    Marty, Bernard; Avice, Guillaume; Bekaert, David V.; Broadley, Michael W.

    2018-05-01

    Fluids trapped in inclusions in well-characterized Archaean hydrothermal quartz crystals were analyzed by the extended argon-argon method, which permits the simultaneous measurement of chlorine and potassium concentrations. Argon and nitrogen isotopic compositions of the trapped fluids were also determined by static mass spectrometry. Fluids were extracted by stepwise crushing of quartz samples from North Pole (NW Australia) and Barberton (South Africa) 3.5-3.0-Ga-old greenstone belts. The data indicate that fluids are a mixture of a low salinity end-member, regarded as the Archaean oceanic water, and several hydrothermal end-members rich in Cl, K, N, and radiogenic parentless 40Ar. The low Cl-K end-member suggests that the salinity of the Archaean oceans was comparable to the modern one, and that the potassium content of the Archaean oceans was lower than at present by about 40%. A constant salinity of the oceans through time has important implications for the stabilization of the continental crust and for the habitability of the ancient Earth.

  1. Organic compounds in fluid inclusions of Archean quartz-Analogues of prebiotic chemistry on early Earth.

    Science.gov (United States)

    Schreiber, Ulrich; Mayer, Christian; Schmitz, Oliver J; Rosendahl, Pia; Bronja, Amela; Greule, Markus; Keppler, Frank; Mulder, Ines; Sattler, Tobias; Schöler, Heinz F

    2017-01-01

    The origin of life is still an unsolved mystery in science. Hypothetically, prebiotic chemistry and the formation of protocells may have evolved in the hydrothermal environment of tectonic fault zones in the upper continental crust, an environment where sensitive molecules are protected against degradation induced e.g. by UV radiation. The composition of fluid inclusions in minerals such as quartz crystals which have grown in this environment during the Archean period might provide important information about the first organic molecules formed by hydrothermal synthesis. Here we present evidence for organic compounds which were preserved in fluid inclusions of Archean quartz minerals from Western Australia. We found a variety of organic compounds such as alkanes, halocarbons, alcohols and aldehydes which unambiguously show that simple and even more complex prebiotic organic molecules have been formed by hydrothermal processes. Stable-isotope analysis confirms that the methane found in the inclusions has most likely been formed from abiotic sources by hydrothermal chemistry. Obviously, the liquid phase in the continental Archean crust provided an interesting choice of functional organic molecules. We conclude that organic substances such as these could have made an important contribution to prebiotic chemistry which might eventually have led to the formation of living cells.

  2. Carbothermal Reduction of Quartz and Carbon Pellets at Elevated Temperatures

    Science.gov (United States)

    Li, Fei; Tangstad, Merete; Ringdalen, Eli

    2018-02-01

    In this study, the carbothermal reduction of pellets composed of quartz and carbon at temperatures between 1898 K and 1948 K (1625 °C and 1675 °C) are investigated. The main product from this reaction is silicon carbide (SiC). The reduction of quartz with carbon black, charcoal, coke, coal, and pre-heated coal in the pellet were compared to investigate the different carbon resources used in silicon production. Charcoal and coke have high SiO reactivity, while carbon black and coal (pre-heated coal) have low SiO reactivity. Charcoal and carbon black show better matching between quartz/carbon reactivity and SiO reactivity, and will lose less SiO gas than coke and pre-heated coal. Coal has a high volatile content and is thus not recommended as a raw material for the pellets.

  3. Luminescence quartz dating of lime mortars. A first research approach

    International Nuclear Information System (INIS)

    Zacharias, N.; Mauz, B.; Michael, C.T.

    2002-01-01

    Lime mortars mixed with sand are well suited for connecting structural materials, like stones and bricks, due to the mechanical properties this material exhibits. Their extensive use in architectural and decorative works during the last 4000 years motivated the introduction of the 'Luminescence clock' for age determination of mortars. The same principles as for quartz optically stimulated luminescence (OSL) dating of sediments were applied for age estimation of a mortar fragment removed from a Byzantine church monument dated by archaeological means to 1050-1100 years ago (the first half of the 10th century). The OSL from the quartz was monitored under blue light stimulation and UV detection, using a single-aliquot-regenerative-dose protocol. The quartz-OSL dating of the mortar resulted in 870±230 a. TL polymineral fine grain dating was also performed on a brick fragment which was connected to the mortar, resulting in a TL age of 1095±190 a. (author)

  4. Carbothermal Reduction of Quartz and Carbon Pellets at Elevated Temperatures

    Science.gov (United States)

    Li, Fei; Tangstad, Merete; Ringdalen, Eli

    2018-06-01

    In this study, the carbothermal reduction of pellets composed of quartz and carbon at temperatures between 1898 K and 1948 K (1625 °C and 1675 °C) are investigated. The main product from this reaction is silicon carbide (SiC). The reduction of quartz with carbon black, charcoal, coke, coal, and pre-heated coal in the pellet were compared to investigate the different carbon resources used in silicon production. Charcoal and coke have high SiO reactivity, while carbon black and coal (pre-heated coal) have low SiO reactivity. Charcoal and carbon black show better matching between quartz/carbon reactivity and SiO reactivity, and will lose less SiO gas than coke and pre-heated coal. Coal has a high volatile content and is thus not recommended as a raw material for the pellets.

  5. Assessment of the potential for dating secondary calcite and quartz in fault zones

    International Nuclear Information System (INIS)

    Morency, Maurice

    1982-03-01

    Calcite and quartz occur frequently as secondary minerals in faults. In many instances these minerals are not deformed. Calcite, for example, often exhibits an undisturbed fibrous habit or appears as euhedral crystals. Direct dating of euhedral crystals would provide a minimum age of the last movement along a fault, whereas dating of fibrous crystals would furnish the real age of the last movement. This information would be essential in the evaluation and selection of sites for both nuclear power reactors and nuclear waste disposal. In the Canadian context, to be successful, the technique should be able to date minerals as old as tens of millions of years. In this study both isotopic and radioactive damage techniques were considered. It was found that thermoluminescence, thermally stimulated current, and electron spin resonance offer possibilities. Recent electron spin resonance studies of ancient flints have yielded dates of several hundred million years. It is anticipated that in the near future a combination of the above techniques will be extensively used in the field of geochronology

  6. An experimental study of hydroxyl in quartz using infrared spectroscopy and ion microprobe techniques

    Energy Technology Data Exchange (ETDEWEB)

    Rovetta, M. R.; Blacic, J. D.; Hervig, R. L.; Holloway, J. R.

    1989-05-10

    We have measured the concentrations of hydroxyl, deuterium, Al, Fe, Li,Na, K, and Rb in a natural quartz crystal before and after hydrothermaltreatment at 1.5 GPa and 800/degree/--1050 /degree/C. We employed microbeam infraredspectroscopy and ion probe techniques to avoid impurities trapped in healedcracks and fluid inclusions that might bias a normal bulk analysis.The /ital f//sub H/sub 2// of our experiments were buffered to thehematite-magnetite-(OH)fluid, nickel-nickel oxide-(OH)fluid, oriron-wustite-(OH)fluid phase assemblages. After hydrothermal treatment,the samples contained local concentrations of hydrogen or deuterium ofseveral hundred atoms/10/sup 6/ Si (the starting crystal contained 45 H/10/sup 6/ Si).We did several experiments with Al/sub 2/O/sub 3/ or RbCl added to the sample chargeand found local Al enrichment where the deuterium concentration was highbut no Rb enrichment. Finally, we measured trace elements and hydroxyl in aquartz sample after plastic deformation in a talc furnace assembly; inregions of the sample containing basal and prismatic deformation lamellae(but no visible healed microcracks at 400/times/ optical magnification)hydroxyl had increased to /similar to/200 oO/10/sup 6/ Si with no increase in Al or Fe.Samples enriched in hydroxyl but not Al (including the plastically strainedsample) gave infrared spectra resembling natural amethyst crystals.

  7. Mass changes in NSTX Surface Layers with Li Conditioning as Measured by Quartz Microbalances

    International Nuclear Information System (INIS)

    Skinner, C.H.; Kugel, H.W.; Roquemore, A.L.; Krstic, P.S.; Beste, A.

    2008-01-01

    Dynamic retention, lithium deposition, and the stability of thick deposited layers were measured by three quartz crystal microbalances (QMB) deployed in plasma shadowed areas at the upper and lower divertor and outboard midplane in the National Spherical Torus Experiment (NSTX). Deposition of 185 (micro)/g/cm 2 over 3 months in 2007 was measured by a QMB at the lower divertor while a QMB on the upper divertor, that was shadowed from the evaporator, received an order of magnitude less deposition. During helium glow discharge conditioning both neutral gas collisions and the ionization and subsequent drift of Li + interrupted the lithium deposition on the lower divertor. We present calculations of the relevant mean free paths. Occasionally strong variations in the QMB frequency were observed of thick lithium films suggesting relaxation of mechanical stress and/or flaking or peeling of the deposited layers.

  8. Characterization of the optical grade synthetic quartz by X-ray topography

    International Nuclear Information System (INIS)

    Tanaka, Marcos S.; Suzuki, Carlos K.; Iwasaki, Fumiko

    1996-01-01

    The first initiative to develop a technology to grow the optical grade synthetic quartz in our country has been conducted by the UNICAMP - JICA - ABC Crystals collaboration. This research shows that the solid inclusions concentrations is practically inexistent, less than 0.03 incl/cm 3 , what satisfy the international standard requirements. On the other hand, the characterization studies by X-ray topography enabled us to estimate the dislocation line density of order of 1200 lines/cm 2 . This value is higher than to the usual international standard requirements. From this study, we obtained a full knowledge of defects origin, where the optimization process could be done by using seeds with superior quality. (author)

  9. Quartz microbalance device for transfer into ultrahigh vacuum systems

    International Nuclear Information System (INIS)

    Stavale, F.; Achete, C. A.; Niehus, H.

    2008-01-01

    An uncomplicated quartz microbalance device has been developed which is transferable into ultrahigh vacuum (UHV) systems. The device is extremely useful for flux calibration of different kinds of material evaporators. Mounted on a commercial specimen holder, the device allows fast quartz microbalance transfer into the UHV and subsequent positioning exactly to the sample location where subsequent thin film deposition experiments shall be carried out. After backtransfer into an UHV sample stage, the manipulator may be loaded in situ with the specimen suited for the experiment. The microbalance device capability is demonstrated for monolayer and submonolayer vanadium depositions with an achieved calibration sensitivity of less the 0.001 ML coverage.

  10. Nature sunlight bleaching of Ti center ESR signal in quartz

    International Nuclear Information System (INIS)

    Yin Gongming; Liu Chunru; Li Jianping; Fang Jiahu; Gao Lu; Lin Min

    2009-01-01

    Quartz grains were extracted from granite. Bleaching was carried out in four different area chosen for their different altitudes (Beijing, Yinchuan, Germu, Lhasa), in order to observe their behavior under different intensities of the UV (Ultra violet) component of sunlight. The result of our experiments indicate that the Ti center signal is totally bleachable by the natural sunlight and show that the Ti center signal was reduced to zero after about 128 h in Beijing and after 56 h for Lhasa. We can speculate that different intensity of the UV component of sunlight lead to different minimal time necessary to obtain the total bleaching of the quartz sample. (authors)

  11. Gas loading of graphene-quartz surface acoustic wave devices

    Science.gov (United States)

    Whitehead, E. F.; Chick, E. M.; Bandhu, L.; Lawton, L. M.; Nash, G. R.

    2013-08-01

    Graphene was transferred to the propagation path of quartz surface acoustic wave devices and the attenuation due to gas loading of air and argon measured at 70 MHz and 210 MHz and compared to devices with no graphene. Under argon loading, there was no significant difference between the graphene and non-graphene device and the values of measured attenuation agree well with those calculated theoretically. Under air loading, at 210 MHz, there was a significant difference between the non-graphene and graphene devices, with the average value of attenuation obtained with the graphene devices being approximately twice that obtained from the bare quartz devices.

  12. Quantification of coating aging using impedance measurements

    NARCIS (Netherlands)

    Westing, E.P.M. van; Weijde, D.H. van der; Vreijling, M.P.W.; Ferrari, G.M.; Wit, J.H.W. de

    1998-01-01

    This chapter shows the application results of a novel approach to quantify the ageing of organic coatings using impedance measurements. The ageing quantification is based on the typical impedance behaviour of barrier coatings in immersion. This immersion behaviour is used to determine the limiting

  13. High temperature impedance spectroscopy of barium stannate

    Indian Academy of Sciences (India)

    ... differential thermal analysis, thermogravimetric analysis and Fourier transform infrared techniques. Electrical properties were studied using a.c. impedance spectroscopy technique in the temperature range of 50–650 °C and frequency range of 10 Hz–13 MHz. The complex impedance plots at temperature ≥ 300 °C show ...

  14. Impedance of a slotted-pipe kicker

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Feng [Academia Sinica, Beijing, BJ (China). Inst. of High Energy Physics

    1996-08-01

    This paper introduces the principle of a new slotted kicker simply, which is made by using vacuum pipe itself with proper slits as current conductors, and then, presents a rough estimation of its longitudinal and transverse impedance, respectively. Calculation shows that its impedance is reduced significantly compared to our present air-coil kicker. (author)

  15. impedance calculations of induction machine rotor conductors.

    African Journals Online (AJOL)

    Dr Obe

    computed. The parallel R-L network shown in figure 3 is used in the modeling of the rotor bars. The network total impedance is given by,. (19). Where,. 5. simulation Results. MATLAB m-file for the calculation of the total impedance of the rectangular and trapezoidal rotor bars is developed [10]. The parameters of the bars.

  16. Impedance of Surface Footings on Layered Ground

    DEFF Research Database (Denmark)

    Andersen, Lars; Clausen, Johan Christian

    2005-01-01

    is discussed. Based on the Green's function for a stratified half-space, the impedance of a surface footing with arbitrary shape is computed. A wind turbine foundation is analysed in the frequency range 0 to 3 Hz. Analyses show that soil stratification may lead to a significant changes in the impedance related...

  17. Impedance of Surface Footings on Layered Ground

    DEFF Research Database (Denmark)

    Andersen, Lars; Clausen, Johan

    2008-01-01

    is discussed. Based on the Green's function for a stratified half-space, the impedance of a surface footing with arbitrary shape is computed. A wind turbine foundation is analysed in the frequency range 0-3 Hz. Analyses show that soil stratification may lead to significant changes in the impedance related...

  18. Quadratic Boost A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Chub, Andrii

    2016-01-01

    A novel quadratic boost A-source impedance network is proposed to realize converters that demand very high voltage gain. To satisfy the requirement, the network uses an autotransformer where the obtained gain is quadratically dependent on the duty ratio and is unmatched by any existing impedance...

  19. Impedance interactions in bidirectional cascaded converter

    DEFF Research Database (Denmark)

    Tian, Yanjun; Loh, Poh Chiang; Chen, Zhe

    2016-01-01

    A cascaded converter is built by connecting one elementary converter to another. Output impedance of one converter will therefore interact with input impedance of the other converter. This interaction will change when power flow reverses. To compare this difference, an investigation is performed...

  20. FDTD modeling of thin impedance sheets

    Science.gov (United States)

    Luebbers, Raymond J.; Kunz, Karl S.

    1991-01-01

    Thin sheets of resistive or dielectric material are commonly encountered in radar cross section calculations. Analysis of such sheets is simplified by using sheet impedances. In this paper it is shown that sheet impedances can be modeled easily and accurately using Finite Difference Time Domain (FDTD) methods.

  1. Possibilities of electrical impedance tomography in gynecology

    International Nuclear Information System (INIS)

    Trokhanova O V; Chijova Y A; Okhapkin M B; Korjenevsky A V; Tuykin T S

    2013-01-01

    The paper describes results of comprehensive EIT diagnostics of mammary glands and cervix. The data were obtained from examinations of 170 patients by EIT system MEM (multi-frequency electrical impedance mammograph) and EIT system GIT (gynecological impedance tomograph). Mutual dependence is discussed.

  2. Fractional Order Element Based Impedance Matching

    KAUST Repository

    Radwan, Ahmed Gomaa

    2014-06-24

    Disclosed are various embodiments of methods and systems related to fractional order element based impedance matching. In one embodiment, a method includes aligning a traditional Smith chart (|.alpha.|=1) with a fractional order Smith chart (|.alpha.|.noteq.1). A load impedance is located on the traditional Smith chart and projected onto the fractional order Smith chart. A fractional order matching element is determined by transitioning along a matching circle of the fractional order Smith chart based at least in part upon characteristic line impedance. In another embodiment, a system includes a fractional order impedance matching application executed in a computing device. The fractional order impedance matching application includes logic that obtains a first set of Smith chart coordinates at a first order, determines a second set of Smith chart coordinates at a second order, and determines a fractional order matching element from the second set of Smith chart coordinates.

  3. Impedance of finite length resistive cylinder

    Directory of Open Access Journals (Sweden)

    S. Krinsky

    2004-11-01

    Full Text Available We determine the impedance of a cylindrical metal tube (resistor of radius a, length g, and conductivity σ attached at each end to perfect conductors of semi-infinite length. Our main interest is in the asymptotic behavior of the impedance at high frequency (k≫1/a. In the equilibrium regime, ka^{2}≪g, the impedance per unit length is accurately described by the well-known result for an infinite length tube with conductivity σ. In the transient regime, ka^{2}≫g, where the contribution of transition radiation arising from the discontinuity in conductivity is important, we derive an analytic expression for the impedance and compute the short-range wakefield. The analytic results are shown to agree with numerical evaluation of the impedance.

  4. Rapid Crystallization of the Bishop Magma

    Science.gov (United States)

    Gualda, G. A.; Anderson, A. T.; Sutton, S. R.

    2007-12-01

    Substantial effort has been made to understand the longevity of rhyolitic magmas, and particular attention has been paid to the systems in the Long Valley area (California). Recent geochronological data suggest discrete magma bodies that existed for hundreds of thousands of years. Zircon crystallization ages for the Bishop Tuff span 100-200 ka, and were interpreted to reflect slow crystallization of a liquid-rich magma. Here we use the diffusional relaxation of Ti zoning in quartz to investigate the longevity of the Bishop magma. We have used such an approach to show the short timescales of crystallization of Ti-rich rims on quartz from early- erupted Bishop Tuff. We have now recognized Ti-rich cores in quartz that can be used to derive the timescales of their crystallization. We studied four samples of the early-erupted Bishop. Hand-picked crystals were mounted on glass slides and polished. Cathodoluminescence (CL) images were obtained using the electron microprobe at the University of Chicago. Ti zoning was documented using the GeoSoilEnviroCARS x-ray microprobe at the Advanced Photon Source (Argonne National Lab). Quartz crystals in all 4 samples include up to 3 Ti-bearing zones: a central core (50-100 μm in diameter, ca. 50 ppm Ti), a volumetrically predominant interior (~40 ppm Ti), and in some crystals a 50-100 μm thick rim (50 ppm Ti). Maximum estimates of core residence times were calculated using a 1D diffusion model, as the time needed to smooth an infinitely steep profile to fit the observed profile. Surprisingly, even for the largest crystals studied - ca. 2 mm in diameter - core residence times are less than 1 ka. Calculated growth rates imply that even cm-sized crystals crystallized in less than 10 ka. Crystal size distribution data show that crystals larger than 3 mm are exceedingly rare, such that the important inference is that the bulk of the crystallization of the early-erupted Bishop magma occurred in only a few thousand years. This timescale

  5. Single Crystals Grown Under Unconstrained Conditions

    Science.gov (United States)

    Sunagawa, Ichiro

    Based on detailed investigations on morphology (evolution and variation in external forms), surface microtopography of crystal faces (spirals and etch figures), internal morphology (growth sectors, growth banding and associated impurity partitioning) and perfection (dislocations and other lattice defects) in single crystals, we can deduce how and by what mechanism the crystal grew and experienced fluctuation in growth parameters through its growth and post-growth history under unconstrained condition. The information is useful not only in finding appropriate way to growing highly perfect and homogeneous single crystals, but also in deciphering letters sent from the depth of the Earth and the Space. It is also useful in discriminating synthetic from natural gemstones. In this chapter, available methods to obtain molecular information are briefly summarized, and actual examples to demonstrate the importance of this type of investigations are selected from both natural minerals (diamond, quartz, hematite, corundum, beryl, phlogopite) and synthetic crystals (SiC, diamond, corundum, beryl).

  6. A new equation of state for α-quartz

    Science.gov (United States)

    Magyar, Rudolph; Carpenter, John

    2015-06-01

    Quartz (SiO2) is often used as an optically transparent window for visar signals in shock experiments and is itself an active component of the experiments. Therefore, the shock response of quartz is an important input that must be known to high fidelity for precise measurement of other materials. We describe on-going work to develop a wide-range equation of state table that includes multiple phases and incorporates the latest high quality experimental and density functional theory (DFT) calculations. The emphasis in this work is the proper description of α-quartz along its principal Hugoniot through Stishovite and liquid phases. While molecular dissociation occurs at high pressures and temperatures, we find that an additional dissociation model is unnecessary. Although SiO2 possesses a number of solid phases, we restrict our focus to α-quartz and Stishovite as these two provide the density change along the Hugoniot path. We compare the model to recently measured data on Sandia's Z-machine. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corporation, a wholly owned subsidiary of Lockheed Martin Corporation, for the U.S. Department of Energy's National Nuclear Security Administration under contract DE.

  7. Food irradiation dosimetry using thermoluminescence of quartz sand

    International Nuclear Information System (INIS)

    Khan, H.M.; Ehlermann, D.A.E.

    1993-01-01

    Thermoluminescence of quartz sand, which is inert and concomitant to several food materials, has been investigated for applications in food irradiation dosimetry and detection of irradiated foods. The glow curves consist of at least three overlapping peaks from 100 to 420 C. The peak at lower temperature is not stable and decays quickly at room temperature. However, the peaks at higher temperature are stable and more useful for dosimetry work. The intensity of the peak at 360 C, measured using different optical filters, shows a linear response in the range of 0.05 to 23 kGy. Stability of these signals at different annealing temperatures has been investigated. Thermoluminescence from adhering minerals and contaminating dust in different food materials has been found useful for the detection of irradiation treatment. Since quartz is frequently one of these minerals, further computerized deconvolution of individual glow peaks from the complex glow curves of quartz sand was carried out which improves the dosimetric results. Possible applications of thermoluminescence of quartz sand in food irradiation dosimetry and detection of irradiated foods have been discussed. (orig.)

  8. Characterization of silica quartz as raw material in photovoltaic applications

    Energy Technology Data Exchange (ETDEWEB)

    Boussaa, S. Anas, E-mail: sabiha.anas@gmail.com; Kheloufi, A.; Kefaifi, A.; Kerkar, F. [Division croissance cristalline et procédés métallurgiques CCPM Centre de recherche en technologie des semi-conducteurs pour l’énergétique (C.R.T.S.E) 02 Bd Frantz Fanon BP. 140 Alger 7 merveilles, Alger 16200 (Algeria); Zaourar, N. Boutarek [Laboratoire des technologies des matériaux, USTHB, B.P. 32 El Alia, Bab Ezzouar, Alger, Algérie 16111 (Algeria)

    2016-07-25

    Raw materials are essential for the functioning of modern societies, and access to these raw materials is vital to the world economy. Sustainable development, both globally level, raises important new challenges associated with access and efficient use of raw materials. High purity quartz, is consider as a critical raw material and it is a rare commodity that only forms under geological conditions where a narrow set of chemical and physical parameters is fulfilled. When identified and following special beneficiation techniques, high purity quartz obtains very attractive prices and is applied in high technology sectors that currently are under rapid expansion such as photovoltaic solar cells, silicon metal - oxide wafers in the semiconductor industry and long distance optical fibers that are used in communication networks. Crystalline silicon remains the principal material for photovoltaic technology. Metallurgical silicon is produced industrially by the reduction of silica with carbon in an electric arc furnace at temperatures higher than 2000 °C in the hottest parts, by a reaction that can be written ideally as: SiO{sub 2} + 2C = Si + 2CO. The aim of this study has been to test experimental methods for investigating the various physical and chemical proprieties of Hoggar quartz with different techniques: X Ray Fluorescence, infra-red spectroscopy, Scanning Electron Microscopy, Optic Microscopy, Carbon Analyzer and Vickers Hardness. The results show finally that the quartz has got good result in purity but need enrichment for the photovoltaic application.

  9. Evaluation of trapping parameters of annealed natural quartz

    International Nuclear Information System (INIS)

    Zhou, Rui; Wei, Ming-Jian; Song, Bo; Zhang, Yan; Zhao, Qiu-Yue; Pan, Bao-Lin; Li, Teng-Fei

    2016-01-01

    The thermoluminescence (TL) trapping parameters of annealed quartz have been investigated. The apparent TL peaks observed at temperatures of 133 °C, 211 °C, 266 °C and 405 °C, respectively, were named Peak I, Peak II, Peak III and Peak IV. The T_m − T_s_t_o_p method is applied to investigate the number of peaks and their positions, and to obtain the trap distributions in the quartz. Peak shape (PS), Hoogenstraaten method (Various Heating Rates Method, VHR), and Computerized Glow Curve Deconvolution (CGCD) are used to evaluate the trapping parameters of the annealed quartz. The glow curve can be considered as a superposition of at least nine overlapping peaks. These peaks show up at 133 °C, 211 °C, 266 °C, 308 °C, 333 °C, 384 °C, 441 °C, 466 °C and 484 °C. The PS method can be only used in evaluating the parameters for Peaks I. The VHR method can be used in evaluating the trapping parameters for the first three peaks. CGCD method is complementary to obtaining parameters for the sub-peaks, and the thermal quenching correction with the Urbach’s method is necessary. The Urbach’s coefficient for the quartz is 30.03 kT_m.

  10. Uraniferous quartz-pebble conglomerates in South Africa

    International Nuclear Information System (INIS)

    von Backstroem, J.W.

    1981-01-01

    The purpose of this paper is to give a short background statement summarizing data on the Dominion Reef Group, the Witwatersrand Supergroup, and the Ventersdorp Contact Reef, with particular reference to the close relationship of gold and uranium with sedimentary features as well as the mineralization, conditions of deposition, and the nature of the quartz-pebble conglomerates

  11. Absorbed dose evaluations in retrospective dosimetry: Methodological developments using quartz

    DEFF Research Database (Denmark)

    Bailiff, I.K.; Bøtter-Jensen, L.; Correcher, V.

    2000-01-01

    Dose evaluation procedures based on luminescence techniques were applied to 50 quartz samples extracted from bricks that had been obtained from populated or partly populated settlements in Russia and Ukraine downwind of the Chernobyl NPP. Determinations of accrued dose in the range similar to 30...

  12. A Transimpedance Amplifier for Remotely Located Quartz Tuning Forks

    OpenAIRE

    Kleinbaum, Ethan; Csathy, Gabor

    2012-01-01

    The cable capacitance in cryogenic and high vacuum applications of quartz tuning forks imposes severe constraints on the bandwidth and noise performance of the measurement. We present a single stage low noise transimpedance amplifier with a bandwidth exceeding 1 MHz and provide an in-depth analysis of the dependence of the amplifier parameters on the cable capacitance.

  13. Note: a transimpedance amplifier for remotely located quartz tuning forks.

    Science.gov (United States)

    Kleinbaum, Ethan; Csáthy, Gábor A

    2012-12-01

    The cable capacitance in cryogenic and high vacuum applications of quartz tuning forks imposes severe constraints on the bandwidth and noise performance of the measurement. We present a single stage low noise transimpedance amplifier with a bandwidth exceeding 1 MHz and provide an in-depth analysis of the dependence of the amplifier parameters on the cable capacitance.

  14. Triplet states at an O vacancy in alpha-quartz

    DEFF Research Database (Denmark)

    Lægsgaard, Jesper

    2002-01-01

    The energy landscape of an alpha-quartz O vacancy in the lowest triplet state is investigated. Four local minima are identified and geometries, total energies, and electron paramagnetic resonance (EPR) parameters are obtained. On the basis of calculated values for the magnetic dipole interaction...

  15. Evaluation of trapping parameters of annealed natural quartz

    Energy Technology Data Exchange (ETDEWEB)

    Zhou, Rui [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Shisanling Seismic Station, Institute of Earthquake Science, CEA, 102200 Beijing (China); Wei, Ming-Jian, E-mail: weimj@cnu.edu.cn [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Song, Bo [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); Beijing Jing Yuan School, 100040 Beijing (China); Zhang, Yan [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China); School of TaiPingqiao, Nan Lu of West Railway Station, 100073 Beijing (China); Zhao, Qiu-Yue [Key Laboratory of Tourism and Resources Environment in Universities of Shandong, Taishan University, 271000 Tai’an (China); Pan, Bao-Lin; Li, Teng-Fei [College of Resources, Environment & Tourism, Capital Normal University, 100048 Beijing (China)

    2016-05-15

    The thermoluminescence (TL) trapping parameters of annealed quartz have been investigated. The apparent TL peaks observed at temperatures of 133 °C, 211 °C, 266 °C and 405 °C, respectively, were named Peak I, Peak II, Peak III and Peak IV. The T{sub m} − T{sub stop} method is applied to investigate the number of peaks and their positions, and to obtain the trap distributions in the quartz. Peak shape (PS), Hoogenstraaten method (Various Heating Rates Method, VHR), and Computerized Glow Curve Deconvolution (CGCD) are used to evaluate the trapping parameters of the annealed quartz. The glow curve can be considered as a superposition of at least nine overlapping peaks. These peaks show up at 133 °C, 211 °C, 266 °C, 308 °C, 333 °C, 384 °C, 441 °C, 466 °C and 484 °C. The PS method can be only used in evaluating the parameters for Peaks I. The VHR method can be used in evaluating the trapping parameters for the first three peaks. CGCD method is complementary to obtaining parameters for the sub-peaks, and the thermal quenching correction with the Urbach’s method is necessary. The Urbach’s coefficient for the quartz is 30.03 kT{sub m}.

  16. Electron spin resonance of Fe4+ in amethyst quartz

    International Nuclear Information System (INIS)

    Cox, R.T.

    1975-01-01

    The ESR spectrum of Fe 4+ was looked for in amethyst quartz. Besides saturated Fe 3+ lines, ESR lines of a new paramagnetic center whose spin-lattice relaxation time is relatively short were observed. They could be attributed to Fe 4+ [fr

  17. Absorption and luminescence of crystalline quartz under electron nanosecond irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Gritsenko, B P; Lisitsyn, V M; Stepanchuk, V N [Tomskij Politekhnicheskij Inst. (USSR)

    1981-02-01

    The purpose of the study is continuation of investigations of principal regularities of production and destruction of short-lived defects in quartz and accompanying luminescence under electron pulse irradiation. For investigation purposes samples of crystalline synthetic quartz have been used. The irradiation has been performed at 80-400 K temperatures by means of an electron pulse accelerator with parameters: electron flow pulse duration 10 ns, pulse current density up to 1000 A/cm/sup 2/, electron mean energy 200 keV. Temperature-time characteristics of absorption and luminescence spectrum are studied. It has been found that quartz irradiation by electron pulses of nanosecond duration leads to appearance of short-lived bands of optical absorption at 4.1 and 5.15 eV to which by kinetic parameters correspond luminescence bands at 2.6 and 3.1 eV, respectively. The enumerated absorption bands are induced by quartz irradiation independently of the prehistory and phase state of the sample and are caused obviously by intrinsic radiation defects. Possible models of such defects are suggested.

  18. QUARTZ: a numerical simulation of an asymmetric electrostatic accelerator

    International Nuclear Information System (INIS)

    Wooten, J.W.; Drooks, L.J.; McCollough, D.H.; McGaffey, R.W.; Whealton, J.H.

    1979-01-01

    The physics and numerical aspects of the development of the computer code QUARTZ are given. This code includes the (1) use of a finite element code to obtain solutions of Poisson's equation in an asymmetric, three-dimensional volume; (2) inclusion of space charge neutralization by electrons; and (3) inclusion of ion space charge through an iterative procedure

  19. Hydrothermal Growth of Polyscale Crystals

    Science.gov (United States)

    Byrappa, Kullaiah

    In this chapter, the importance of the hydrothermal technique for growth of polyscale crystals is discussed with reference to its efficiency in synthesizing high-quality crystals of various sizes for modern technological applications. The historical development of the hydrothermal technique is briefly discussed, to show its evolution over time. Also some of the important types of apparatus used in routine hydrothermal research, including the continuous production of nanosize crystals, are discussed. The latest trends in the hydrothermal growth of crystals, such as thermodynamic modeling and understanding of the solution chemistry, are elucidated with appropriate examples. The growth of some selected bulk, fine, and nanosized crystals of current technological significance, such as quartz, aluminum and gallium berlinites, calcite, gemstones, rare-earth vanadates, electroceramic titanates, and carbon polymorphs, is discussed in detail. Future trends in the hydrothermal technique, required to meet the challenges of fast-growing demand for materials in various technological fields, are described. At the end of this chapter, an Appendix 18.A containing a more or less complete list of the characteristic families of crystals synthesized by the hydrothermal technique is given with the solvent and pressure-temperature (PT) conditions used in their synthesis.

  20. Tracking of electrochemical impedance of batteries

    Science.gov (United States)

    Piret, H.; Granjon, P.; Guillet, N.; Cattin, V.

    2016-04-01

    This paper presents an evolutionary battery impedance estimation method, which can be easily embedded in vehicles or nomad devices. The proposed method not only allows an accurate frequency impedance estimation, but also a tracking of its temporal evolution contrary to classical electrochemical impedance spectroscopy methods. Taking into account constraints of cost and complexity, we propose to use the existing electronics of current control to perform a frequency evolutionary estimation of the electrochemical impedance. The developed method uses a simple wideband input signal, and relies on a recursive local average of Fourier transforms. The averaging is controlled by a single parameter, managing a trade-off between tracking and estimation performance. This normalized parameter allows to correctly adapt the behavior of the proposed estimator to the variations of the impedance. The advantage of the proposed method is twofold: the method is easy to embed into a simple electronic circuit, and the battery impedance estimator is evolutionary. The ability of the method to monitor the impedance over time is demonstrated on a simulator, and on a real Lithium ion battery, on which a repeatability study is carried out. The experiments reveal good tracking results, and estimation performance as accurate as the usual laboratory approaches.

  1. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  2. Identification of irradiated potatoes by impedance

    International Nuclear Information System (INIS)

    Singh, Rita; Singh, Antaryami; Wadhawan, A.K.

    1997-01-01

    The electrical impedance of potatoes irradiated at 60, 90, 150 and 1000 Gy was measured using various frequencies of alternating current. The impedance of the irradiated potatoes was higher than the unirradiated potatoes particularly in the frequency range of 100 Hz to 10 kHz. The ratio of the impedance at 5 kHz to that at 50 Hz (Z5k/Z50) was found to be the best indicator for detection of radiation treatment. (author). 4 refs., 2 figs

  3. Electrical Impedance Measurements of PZT Nanofiber Sensors

    Directory of Open Access Journals (Sweden)

    Richard Galos

    2017-01-01

    Full Text Available Electrical impedance measurements of PZT nanofiber sensors were performed using a variety of methods over a frequency spectrum ranging from DC to 1.8 GHz. The nanofibers formed by electrospinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. Special matching circuits with ultrahigh input impedance were fabricated to produce low noise, measurable sensor outputs. Material properties including resistivity and dielectric constant are derived from the impedance measurements. The resulting material properties are also compared with those of individual nanofibers being tested using conductive AFM and Scanning Conductive Microscopy.

  4. Small-signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Knott, Arnold; Iversen, Niels Elkjær

    2014-01-01

    Specifying the performance of audio ampliers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by the mechanical resonance between the mass of the diaphragm and the compliance of its' suspension which vary from...... driver to driver. Therefore a loudspeaker emulator capable of adjusting its' impedance to a given driver is in need for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible to emulate...... the loudspeaker impedance with an electric circuit and that its' resonance frequency can be changed by tuning two resistors....

  5. RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE

    International Nuclear Information System (INIS)

    HAHN, H.; DAVINO, D.

    2002-01-01

    Kicker magnets typically represent the most important contributors to the transverse impedance budget of accelerators and storage rings. Methods of reducing the impedance value of the SNS extraction kicker presently under construction and, in view of a future performance upgrade, that of the RHIC abort kicker have been thoroughly studied at this laboratory. In this paper, the investigation of a potential improvement from using ferrite different from the BNL standard CMD5005 is reported. Permeability measurements of several ferrite types have been performed. Measurements on two kicker magnets using CMD5005 and C2050 suggest that the impedance of a magnet without external resistive damping, such as the RHIC abort kicker, would benefit

  6. SPATIAL VARIABILITY OF PEDOZEMS MECHANICAL IMPEDANCE

    Directory of Open Access Journals (Sweden)

    Zhukov A.V.

    2013-04-01

    Full Text Available We studied the spatial variability of pedozem mechanical impedance in ResearchRemediation Center of the Dnipropetrovsk State Agrarian University in Ordzhonikidze. Thestatistical distribution of the soil mechanical impedance within the studied area is characterized by deviation from the normal law in 0–10 and 30–50 cm layers from the surface. 2D and 3D modeling shows the structural design of the soil as locations of high mechanical impedance which found in the soils with less hardness.

  7. Sound Propagation An impedance Based Approach

    CERN Document Server

    Kim, Yang-Hann

    2010-01-01

    In Sound Propagation: An Impedance Based Approach , Professor Yang-Hann Kim introduces acoustics and sound fields by using the concept of impedance. Kim starts with vibrations and waves, demonstrating how vibration can be envisaged as a kind of wave, mathematically and physically. One-dimensional waves are used to convey the fundamental concepts. Readers can then understand wave propagation in terms of characteristic and driving point impedance. The essential measures for acoustic waves, such as dB scale, octave scale, acoustic pressure, energy, and intensity, are explained. These measures are

  8. Quartz reserves in Brazil: planning and photovoltaic industry; Reservas de quartzo no Brasil: planejamento e Industria fotovoltaica

    Energy Technology Data Exchange (ETDEWEB)

    Marczewski, Breitner; Gonzalez, Mariana Pedrosa; Oliveira, Sergio H.F. [Universidade Federal do ABC (UFABC), Santo Andre, SP (Brazil). Dept. de Energia], emails: mariana.gonzalez@ufabc.edu.br, sergio.oliveira@ufabc.edu.br

    2010-07-01

    The goal of this research was examine the availability of part of Brazilian quartz resource for the construction of a photovoltaic industry in the country and the possibility to expand your contribution for others markets. The use of renewable alternative sources of energy has been wining more space in the last years, mainly for the photovoltaic technology. The exponential growth of this technology in the world at an average rate of 20% per year allows understand the importance and contribution for the spheres economic, social and environmental. The solar energy it's renewable and doesn't emit greenhouse gases during the generation of electric energy. Favor this background, research and academic development have been investing to make this technology more efficiency and cheap. In this context, Brazil is in a position unique for several aspects, for example, the incidence of high levels of solar radiation during the year, the amount of reserve of quartz, and now, the knowledge to produce this technology in laboratory scale. So, to achieve an hypothetical scenario for the construction of an national industry, to supply this technology not just for the country, as well to Latin America, help the planning and gives credibility for possible actions to be taken. Through the proposal scenario, the result gained was that is at least part of the reserve of quartz, in this case crystal of quartz enough to attend the insertion of 50 MW/year in the country and the possibility to supply international demand without compromise your on future electronic or photovoltaic industry. (author)

  9. A High Sensitivity Preamplifier for Quartz Tuning Forks in QEPAS (Quartz Enhanced PhotoAcoustic Spectroscopy Applications

    Directory of Open Access Journals (Sweden)

    Tomasz Starecki

    2017-11-01

    Full Text Available All the preamplifiers dedicated for Quartz Enhanced PhotoAcoustic Spectroscopy (QEPAS applications that have so far been reported in the literature have been based on operational amplifiers working in transimpedance configurations. Taking into consideration that QEPAS sensors are based on quartz tuning forks, and that quartz has a relatively high voltage constant and relatively low charge constant, it seems that a transimpedance amplifier is not an optimal solution. This paper describes the design of a quartz QEPAS sensor preamplifier, implemented with voltage amplifier configuration. Discussion of an electrical model of the circuit and preliminary measurements are presented. Both theoretical analysis and experiments show that use of the voltage configuration allows for a substantial increase of the output signal in comparison to the transimpedance circuit with the same tuning fork working in identical conditions. Assuming that the sensitivity of the QEPAS technique depends directly on the properties of the preamplifier, use of the voltage amplifier configuration should result in an increase of QEPAS sensitivity by one to two orders of magnitude.

  10. A High Sensitivity Preamplifier for Quartz Tuning Forks in QEPAS (Quartz Enhanced PhotoAcoustic Spectroscopy) Applications.

    Science.gov (United States)

    Starecki, Tomasz; Wieczorek, Piotr Z

    2017-11-03

    All the preamplifiers dedicated for Quartz Enhanced PhotoAcoustic Spectroscopy (QEPAS) applications that have so far been reported in the literature have been based on operational amplifiers working in transimpedance configurations. Taking into consideration that QEPAS sensors are based on quartz tuning forks, and that quartz has a relatively high voltage constant and relatively low charge constant, it seems that a transimpedance amplifier is not an optimal solution. This paper describes the design of a quartz QEPAS sensor preamplifier, implemented with voltage amplifier configuration. Discussion of an electrical model of the circuit and preliminary measurements are presented. Both theoretical analysis and experiments show that use of the voltage configuration allows for a substantial increase of the output signal in comparison to the transimpedance circuit with the same tuning fork working in identical conditions. Assuming that the sensitivity of the QEPAS technique depends directly on the properties of the preamplifier, use of the voltage amplifier configuration should result in an increase of QEPAS sensitivity by one to two orders of magnitude.

  11. TL response to quartz and aluminum oxide grain for α-irradiation

    International Nuclear Information System (INIS)

    Pan Baolin; Wei Mingjian; Li Dongxu; Liu Zhaowen; Liu Chao; Zhao Shiyuan

    2009-01-01

    Thermoluminescence (TL) response for an α-ray irradiation system ( 241 Am) was examined with quartz grains of 11-40 μm. Quartz grains of different sizes, i.e. 137 Cs), before they were irradiated to different doses by the α-ray irradiation system. TL response to the quartz grain samples was measured. TL response of the quartz grains smaller than 4 μm and 11-40 μm to α-ray irradiation is the best, as the α-rays cannot penetrate quartz larger than 40 μm. The TL response characteristic is related with quartz grain surface area. TL responses to α-irradiation of 11-40 μm quartz and aluminum oxide grains were compared. The α-irradiation TL response of aluminum oxide (330 degree C) is better than the quartz (375 degree C). (authors)

  12. Properties and behavior of quartz for the silicon process

    Energy Technology Data Exchange (ETDEWEB)

    Aasly, Kurt

    2008-07-01

    This PhD-thesis is a result of the study on important properties of quartz as a raw material for the metallurgical production of ferrosilicon and silicon metal. This includes defining mechanical properties important for the size reduction experienced during transport and storage and thermo-mechanical properties of quartz that is important for how the quartz reacts to the high temperatures experienced as it is charged on the furnace. Additionally, softening properties of quartz have been briefly discussed in some of the papers. Another important goal has been to test analytical and experimental methods for investigating the various properties. The investigations of important factors for the mechanical properties of ores and industrial minerals have been carried out as a literature study. The mining operation and transport from mine to smelter has been discussed and several factors that are significant for achieving best possible mechanical properties of the quartz have been identified. The most important factors are related to production in the mine and processing plant, which should be carefully planned to minimize the amount of blast-induced damage in the rock and thus achieve the best possible mechanical strength of the raw material. The amount of fines can be minimized by controlling the handling of the raw materials during the transport and storage. It is especially important to avoid high drops, both high single drops and accumulated height of all the drops in total. Investigations of the thermo-mechanical properties of quartz have been carried out by using different experimental and characterization methods. The petrographic investigations of the raw materials by polarized light microscopy have been important. Thermo-mechanical investigations have been high-temperature microthermometry and shock heating of quartz samples in an induction furnace with subsequent investigations of the heated material. The subsequent investigation included polarized- and

  13. Theory for electrochemical impedance spectroscopy of ...

    Indian Academy of Sciences (India)

    Shweta Dhillon

    generalize phenomenological theory for the Randles-Ershler admittance at the electrode with double layer capacitance ..... impedance (equation 12) curves accounting for the elec- ..... R.K. thanks University of Delhi for the financial support.

  14. Battery impedance spectroscopy using bidirectional grid connected

    Indian Academy of Sciences (India)

    Keywords. Impedance spectroscopy; grid connection; battery converter; state of charge; health monitoring ... The converter is grid connected and controlled to operate at unity power factor. Additional ... Sadhana. Current Issue : Vol. 43, Issue 6.

  15. Impedance and collective effects in the LHC

    Energy Technology Data Exchange (ETDEWEB)

    Gareyte, J [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    After a review of the main LHC parameters, and a brief description of the RF and vacuum systems, the coupling impedances of the main machine elements are given, as well as the resulting thresholds for instabilities. (author)

  16. Electrochemical Impedance Studies of SOFC Cathodes

    DEFF Research Database (Denmark)

    Hjelm, Johan; Søgaard, Martin; Wandel, Marie

    2007-01-01

    Mixed ion- and electron-conducting composite electrodes consisting of doped ceria and perovskite have been studied by electrochemical impedance spectroscopy (EIS) at different temperatures and oxygen partial pressures. This paper aims to describe the different contributions to the polarisation...

  17. Loudspeaker impedance emulator for multi resonant systems

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2015-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by its electrical, mechanical and acoustical properties. Therefore a loudspeaker emulator capable of adjusting...... its impedance to that of a given loudspeaker is desired for measurement purposes. An adjustable RLC based emulator is implemented with switch controlled capacitors, air gap controlled inductors and potentiometers. Calculations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance infinite baffle-, closed box- and the multi resonant vented box-loudspeaker by tuning the component values in the proposed circuit. Future work is outlined and encourage that the proposed impedance emulator is used as part of a control circuit in a switch-mode based...

  18. Modeling degradation in SOEC impedance spectra

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Hauch, Anne; Knibbe, Ruth

    2013-01-01

    Solid oxide cell (SOC) performance is limited by various processes. One way to investigate these processes is by electrochemical impedance spectroscopy. In order to quantify and characterize the processes, an equivalent circuit can be used to model the SOC impedance spectra (IS). Unfortunately......, the optimal equivalent circuit is often unknown and to complicate matters further, several processes contribute to the SOC impedance - making detailed process characterization difficult. In this work we analyze and model a series of IS measured during steam electrolysis operation of an SOC. During testing......, degradation is only observed in the Ni/YSZ electrode and not in the electrolyte or the LSM/YSZ electrode. A batch fit of the differences between the IS shows that a modified Gerischer element provides a better fit to the Ni/YSZ electrode impedance than the frequently used RQ element - albeit neither...

  19. Estimating the short-circuit impedance

    DEFF Research Database (Denmark)

    Nielsen, Arne Hejde; Pedersen, Knud Ole Helgesen; Poulsen, Niels Kjølstad

    1997-01-01

    A method for establishing a complex value of the short-circuit impedance from naturally occurring variations in voltage and current is discussed. It is the symmetrical three phase impedance at the fundamental grid frequency there is looked for. The positive sequence components in voltage...... and current are derived each period, and the short-circuit impedance is estimated from variations in these components created by load changes in the grid. Due to the noisy and dynamic grid with high harmonic distortion it is necessary to threat the calculated values statistical. This is done recursively...... through a RLS-algorithm. The algorithms have been tested and implemented on a PC at a 132 kV substation supplying a rolling mill. Knowing the short-circuit impedance gives the rolling mill an opportunity to adjust the arc furnace operation to keep flicker below a certain level. Therefore, the PC performs...

  20. New Magnetically Coupled Impedance (Z-) Source Networks

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Loh, Poh Chiang

    2016-01-01

    Various Magnetically Coupled Impedance Source (MCIS) networks have been proposed in the literature for increasing voltage gain and modulation index simultaneously, while reducing the number of passive components used in the converter. However, applications of such networks have been limited...

  1. Fractional Order Element Based Impedance Matching

    KAUST Repository

    Radwan, Ahmed Gomaa; Salama, Khaled N.; Shamim, Atif

    2014-01-01

    Disclosed are various embodiments of methods and systems related to fractional order element based impedance matching. In one embodiment, a method includes aligning a traditional Smith chart (|.alpha.|=1) with a fractional order Smith chart (|.alpha

  2. Applications of Nonlinear Electrochemical Impedance Spectroscopy (NLEIS)

    KAUST Repository

    Adler, S. B.

    2013-01-01

    This paper reviews the use of nonlinear electrochemical impedance spectroscopy (NLEIS) in the analysis of SOFC electrode reactions. By combining EIS and NLEIS, as well as other independent information about an electrode material, it becomes possible

  3. The mineralogy and geochemistry of quartz-tourmaline schlieren in the granites of the Primorsky Complex, Western Baikal Region

    Science.gov (United States)

    Savel'eva, V. B.; Bazarova, E. P.; Kanakin, S. V.

    2014-12-01

    Quartz-tourmaline schlieren have been found within rapakivi-like granites of the Early Proterozoic Primorsky Complex in the Western Baikal Region. These rocks are biotite leucogranites with normal alkalinity (A/CNK = 1.00-1.04); a high iron mole fraction (92-95%); a K2O/Na2O value of about 2.0; relatively high F, Li, Rb, Cs, Sn, Pb, Th, and U contents; and low Ba, Sr, Eu, Zn, Sc, and V contents. The schlieren composed of quartz and tourmaline with relics of feldspar also contain fluorite, rare muscovite, chlorite, and accessory rutile, ilmenite, zircon, monazite, xenotime, and bastnäsite. B2O3 and F contents in the schlieren are 2.29-2.63 and 0.30-0.47 wt %, respectively. Fe2O3 (4.8-5.4 wt %), F, and H2O contents are higher in these schlieren than in the host granite, while SiO2, CaO, Na2O, K2O, and P2O5 contents are lower than in host rocks. K2O/Na2O values decrease in the schlieren down to 0.4. Enrichment of the schlieren in Fe and other ore elements (Zn, Co, Cu, Sn, etc.), together with B, F, H2O, and Na, suggests that they crystallized from fluid-saturated melt segregated from aluminosilicate melt in the apical part of a shallow-seated intrusion. The formation of tourmaline may be related to the interaction of the fluid with feldspars in the crystallizing granites; it was accompanied by a separation of fluid F-CO2. Quartz precipitated at the next stage, due to the acidic character of the aqueous fluid. In general, the relationships of minerals in the schlieren indicate distinct fractionation of LREE, HREE, and Y in the fluid-saturated melt.

  4. CSR Impedance for Non-Ultrarelativistic Beams

    International Nuclear Information System (INIS)

    Li, Rui; Tsai, Cheng Y.

    2015-09-01

    For the analysis of the coherent synchrotron radiation (CSR)-induced microbunching gain in the low energy regime, such as when a high-brightness electron beam is transported through a low-energy merger in an energy-recovery linac (ERL) design, it is necessary to extend the CSR impedance expression in the ultrarelativistic limit to the non-ultrarelativistic regime. This paper presents our analysis of CSR impedance for general beam energies.

  5. Compensating for evanescent modes and estimating characteristic impedance in waveguide acoustic impedance measurements

    DEFF Research Database (Denmark)

    Nørgaard, Kren Rahbek; Fernandez Grande, Efren

    2017-01-01

    The ear-canal acoustic impedance and reflectance are useful for assessing conductive hearing disorders and calibrating stimulus levels in situ. However, such probe-based measurements are affected by errors due to the presence of evanescent modes and incorrect estimates or assumptions regarding...... characteristic impedance. This paper proposes a method to compensate for evanescent modes in measurements of acoustic impedance, reflectance, and sound pressure in waveguides, as well as estimating the characteristic impedance immediately in front of the probe. This is achieved by adjusting the characteristic...... impedance and subtracting an acoustic inertance from the measured impedance such that the non-causality in the reflectance is minimized in the frequency domain using the Hilbert transform. The method is thus capable of estimating plane-wave quantities of the sought-for parameters by supplying only...

  6. Development and utilization of liquid quartz light modulating film. Ekisho choko film no kaihatsu to riyo

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, M. (Ajinomoto Co. Inc., Tokyo (Japan))

    1992-03-01

    This paper introduces the polymer dispersed liquid crystal (PDLC) ACT'' sheet, a liquid quartz light modulating film, developed by the Ajinomoto Company in Japan. A mixture of liquid crystal and polymer precursor is sandwiched between polyethylene terephthalate films imparted with transparency conductor made of indium tin oxide (ITO), which is then polymerized by heating or irradiating ultraviolet rays to obtain a PDLC. The film has a thickness as thin as about 0.3 mm, and good processibility. The sheet uses light modulating elements functioning on scatter and permeation of light. Clarification was made on the voltage dependence of cloudiness, total light permeability, straight and parallel light permeability, the response, and the operating voltage. The system consumes small amount of power with a threshold value of about 35V, and is suitable to operate large areas when working on the utility power supply. An incident light having a high diffusion capability when the electric field is turned off exhibits a high clouding function. The system gives an excellent feel of colorlessness and transparency when the electric field is turned on. The performances in heat insulation, infrared reflection capability and noise resistance are expected to be compounded for a functional versatility. 4 refs., 6 figs., 2 tabs.

  7. 75 FR 30282 - Airworthiness Directives; Quartz Mountain Aerospace, Inc. Model 11E Airplanes

    Science.gov (United States)

    2010-06-01

    ... Airworthiness Directives; Quartz Mountain Aerospace, Inc. Model 11E Airplanes AGENCY: Federal Aviation... airworthiness directive (AD) for all Quartz Mountain Aerospace, Inc. Model 11E airplanes. This AD requires you... reference of certain publications listed in this AD. ADDRESSES: Quartz Mountain Aerospace, Inc. is in...

  8. Impedance Based Analysis and Design of Harmonic Resonant Controller for a Wide Range of Grid Impedance

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Blaabjerg, Frede

    2014-01-01

    This paper investigates the effect of grid impedance variation on harmonic resonant current controllers for gridconnected voltage source converters by means of impedance-based analysis. It reveals that the negative harmonic resistances tend to be derived from harmonic resonant controllers...... in the closed-loop output admittance of converter. Such negative resistances may interact with the grid impedance resulting in steady state error or unstable harmonic compensation. To deal with this problem, a design guideline for harmonic resonant controllers under a wide range of grid impedance is proposed...

  9. Spectrographic analysis of metallic silicium and natural quartz

    International Nuclear Information System (INIS)

    Grigoletto, T.; Lordello, A.R.

    1985-01-01

    A method has been developed for the spectrographic determination of B, Mg, Al, Ca, Ti, Mn, Fe, Ni, Cu and Ag in silicon metal and other for Al, Ca, Mg, Ti, Cr, Mn, and Fe in natural quartz. A mixture of the matrix with a proper buffer is excited directly in a dc-arc. High-current (25A) and argon atmosphere are used for both the methods. Silicon metal is blended with 8% NaF and after 1:1 (w/w) with graphite. For natural quartz 20% NaF and 30% graphite by weight is the buffer mixture employed. The lower values in the determinations varies from 0.5 to 40 μg/g and the precision of the analysis from 7% to 45%. (Author) [pt

  10. Measurement of fast risetime megampere currents by quartz gauge

    International Nuclear Information System (INIS)

    Williams, R.R.; McDaniel, D.H.; Stinnett, R.W.

    1980-01-01

    Quartz gauges have been used on the Sandia National Laboratories Proto II accelerator to measure current in the magnetically insulated transmission line at the 11 TW power level. The accelerator delivers 3.5 MA at 2 x 10 14 A/s in a 40 ns pulse to a 0.0127 m diameter aluminum liner to produce a high density plasma. At this radius and dI/dt levels, the B-dot monitors no longer function for the measurement of load current because the monitor suffers electrical breakdown. Quartz pressure gauges mounted at a radius of 0.0086 m have successfully measured the magnetic pressure due to the load current with nanosecond temporal resolution

  11. Natural sunlight bleaching of the aluminum center in quartz

    International Nuclear Information System (INIS)

    Lin Min; Yin Gongming; Han Kongyan; Bao Jifei; Liu Jingwei; Jia Li

    2007-01-01

    The effect of sunlight bleaching on ESR signals from the aluminum center in quartz is reported for two samples of sand-sized quartz, one from a granite and one from a beach sand. The grains were exposed to direct sunlight for periods of time up to 500 h, with bleaching carried out in four different cities in China that are from 50 to 3600 m above sea level. Each sample bleached to the same residual level, ∼55% for the granite and 80% for the beach sand of the initial value after a 200 Gy dose had been given. After 200 h, the bleaching level reached was independent of the height above sea level

  12. Establishment of gold-quartz standard GQS-1

    Science.gov (United States)

    Millard, Hugh T.; Marinenko, John; McLane, John E.

    1969-01-01

    A homogeneous gold-quartz standard, GQS-1, was prepared from a heterogeneous gold-bearing quartz by chemical treatment. The concentration of gold in GQS-1 was determined by both instrumental neutron activation analysis and radioisotope dilution analysis to be 2.61?0.10 parts per million. Analysis of 10 samples of the standard by both instrumental neutron activation analysis and radioisotope dilution analysis failed to reveal heterogeneity within the standard. The precision of the analytical methods, expressed as standard error, was approximately 0.1 part per million. The analytical data were also used to estimate the average size of gold particles. The chemical treatment apparently reduced the average diameter of the gold particles by at least an order of magnitude and increased the concentration of gold grains by a factor of at least 4,000.

  13. Thermal annealing studies in muscovite and in quartz

    International Nuclear Information System (INIS)

    Roberts, J.H.; Gold, R.; Ruddy, F.H.

    1979-06-01

    In order to use Solid State Track Recorders (SSTR) in environments at elevated temperatures, it is necessary to know the thermal annealing characteristics of various types of SSTR. For applications in the nuclear energy program, the principal interest is focused upon the annealing of fission tracks in muscovite mica and in quartz. Data showing correlations between changes in track diameters and track densities as a function of annealing time and temperature will be presented for Amersil quartz glass. Similar data showing changes in track lengths and in track densities will be presented for mica. Time-temperature regions will be defined where muscovite mica can be accurately applied with negligible correction for thermal annealing

  14. Study of green quartz of hydrothermal origin treated by gamma radiation; Estudo do quartzo verde de origem hidrotermal tratado com radiacao gama

    Energy Technology Data Exchange (ETDEWEB)

    Enokihara, Cyro Teiti

    2013-07-01

    A specific variety of quartz showing a green color in nature or induced artificially by radiation is quite rare. This can be explained by the fact that the mechanism of formation of this color is very different from the ones widely discussed in the literature and responsible for the formation of the fumee, citrine and amethyst types of quartz, including the prasiolite (leak green quartz) formed by heating amethyst from Montezuma, Brazil. Only two occurrences are known today, where this type of quartz can be found: Canada, at the Thunder Bay Amethyst Mine, Ontario, a small district, and Brazil, at widely scattered geode occurrences along a 600 km stretch from Quarai at Brazils southernmost tip to Uberlandia in Minas Gerais. These two occurrences have been formed by strong hydrothermal activities, at Thunder Bay due to tectonics and in Brazil by meteoric and hydrothermal waters of the Guarani aquifer. That way much quartz crystals showed a very fast growth history facilitating the formation of growth defects (twinning, small angle tilting, mosaic growth, striations) and the uptake of water in form of micro inclusions, molecular water, silanol (Si-OH) and OH. This type of quartz can be considered 'wet quartz', similar to synthetic quartz. The water content with up to 3200 ppm by weight exceeds the amount of charge balancing cations (Fe, Al, Li). There is no correlation between water content and cations as in other color varieties. Instead, silanol complexes are formed, which by radiation due to gamma rays form the color center NBOHC (non-bonding oxygen hole defect), showing absorption between 590 to 620 nm and leaving a transmission window at about 550nm, responsible for the green color. To characterize samples which will be colored green by gamma rays analyses by ICP, NAA, Electron microscopy, water loss techniques and UV-VIS and NIR-FTIR spectroscopic have been made. The spectroscopic water determination showed less water (up to 2300 ppm by weight

  15. Crystals in crystals

    DEFF Research Database (Denmark)

    Christensen, Claus H.; Schmidt, I.; Carlsson, A.

    2005-01-01

    A major factor governing the performance of catalytically active particles supported on a zeolite carrier is the degree of dispersion. It is shown that the introduction of noncrystallographic mesopores into zeolite single crystals (silicalite-1, ZSM-5) may increase the degree of particle dispersion....... As representative examples, a metal (Pt), an alloy (PtSn), and a metal carbide (beta-Mo2C) were supported on conventional and mesoporous zeolite carriers, respectively, and the degree of particle dispersion was compared by TEM imaging. On conventional zeolites, the supported material aggregated on the outer surface...

  16. Assessing rare earth elements in quartz rich geological samples

    International Nuclear Information System (INIS)

    Santoro, A.; Thoss, V.; Ribeiro Guevara, S.; Urgast, D.; Raab, A.; Mastrolitti, S.; Feldmann, J.

    2016-01-01

    Sodium peroxide (Na_2O_2) fusion coupled to Inductively Coupled Plasma Tandem Mass Spectrometry (ICP-MS/MS) measurements was used to rapidly screen quartz-rich geological samples for rare earth element (REE) content. The method accuracy was checked with a geological reference material and Instrumental Neutron Activation Analysis (INAA) measurements. The used mass-mode combinations presented accurate results (only exception being "1"5"7Gd in He gas mode) with recovery of the geological reference material QLO-1 between 80% and 98% (lower values for Lu, Nd and Sm) and in general comparable to INAA measurements. Low limits of detection for all elements were achieved, generally below 10 pg g"−"1, as well as measurement repeatability below 15%. Overall, the Na_2O_2/ICP-MS/MS method proved to be a suitable lab-based method to quickly and accurately screen rock samples originating from quartz-rich geological areas for rare earth element content; particularly useful if checking commercial viability. - Highlights: • Na_2O_2 fusion coupled to ICP-MS/MS was used to determine REE in quartz-rich samples. • The method accuracy was checked with a geological reference material and INAA. • Results were within 80–98% recovery of QLO-1 reference material, comparable to INAA. • Detection limits were generally below 10 pg g"−"1, and repeatability was below 15%. • Na_2O_2/ICP-MS/MS proved to be a suitable method for REE in quartz-rich samples.

  17. The red thermoluminescence of quartz: 3-D spectral measurements

    International Nuclear Information System (INIS)

    Scholefield, R.B.; Prescott, J.R.

    1999-01-01

    As part of a general study of the thermoluminescence (TL) of quartz, we have examined the 3-D spectra of samples of quartz extracted from a variety of sediments. Blue emission at about 2.6 eV/475 nm, which is the photon energy region commonly used in luminescence dating, seems ubiquitous. Significant emission in the red, ∼1.9 eV/650 nm, has been found at most glow temperatures in all of our samples of Australian quartz sediments, and it is to this that particular attention is paid in the present work. A limited selection of samples from other countries has also been included. The ratio of the intensities of the red and blue emissions varies widely among samples. We have not found any evidence of a correlation between this ratio, nor the intensity of the red emission, with trace element concentration, including that of Al for which a correlation has been previously observed. In the context of luminescence dating, all samples have been examined to see whether they have a rapidly bleaching red component in a similar sense to the well-known 305 deg. C/2.95 eV/420 nm peak in quartz: some samples have such a component--some do not. A suggestive parallelism is found between the blue and red spectra, in that there are 'slowly bleaching' and 'rapidly bleaching' components at similar temperatures in the both red and the blue. However, there is no red component associated with the 110 deg. C peak used in pre-dose dating

  18. A vibrating quartz fork - a tool for cryogenic helium research

    Czech Academy of Sciences Publication Activity Database

    Blažková, Michaela; Člověčko, M.; Eltsov, V. B.; Gažo, E.; de Graaf, R.; Hosio, J.J.; Krusius, M.; Schmoranzer, D.; Schoepe, W.; Skrbek, Ladislav; Skyba, P.; Solntsev, R.E.; Vinen, W. F.

    2008-01-01

    Roč. 150, - (2008), s. 525-535 ISSN 0022-2291 R&D Projects: GA ČR GA202/05/0218 Grant - others:GAUK(CZ) 7953/2007; Transnational Access Programme(XE) RITA -CT-2003-505313 Institutional research plan: CEZ:AV0Z10100520 Keywords : normal 3He * superfluid 3He * superfluid 4He * turbulence, * cavitation * quartz tuning fork Subject RIV: BK - Fluid Dynamics Impact factor: 1.034, year: 2008

  19. Melting and Pressure-Induced Amorphization of Quartz

    OpenAIRE

    Badro, James; Gillet, Philippe; Barrat, Jean-Louis

    1997-01-01

    It has recently been shown that amorphization and melting of ice were intimately linked. In this letter, we infer from molecular dynamics simulations on the SiO2 system that the extension of the quartz melting line in the metastable pressure-temperature domain is the pressure-induced amorphization line. It seems therefore likely that melting is the physical phenomenon responsible for pressure induced amorphization. Moreover, we show that the structure of a "pressure glass" is similar to that ...

  20. Virtual Crystallizer

    Energy Technology Data Exchange (ETDEWEB)

    Land, T A; Dylla-Spears, R; Thorsness, C B

    2006-08-29

    Large dihydrogen phosphate (KDP) crystals are grown in large crystallizers to provide raw material for the manufacture of optical components for large laser systems. It is a challenge to grow crystal with sufficient mass and geometric properties to allow large optical plates to be cut from them. In addition, KDP has long been the canonical solution crystal for study of growth processes. To assist in the production of the crystals and the understanding of crystal growth phenomena, analysis of growth habits of large KDP crystals has been studied, small scale kinetic experiments have been performed, mass transfer rates in model systems have been measured, and computational-fluid-mechanics tools have been used to develop an engineering model of the crystal growth process. The model has been tested by looking at its ability to simulate the growth of nine KDP boules that all weighed more than 200 kg.

  1. single crystals

    Indian Academy of Sciences (India)

    2018-05-18

    May 18, 2018 ... Abstract. 4-Nitrobenzoic acid (4-NBA) single crystals were studied for their linear and nonlinear optical ... studies on the proper growth, linear and nonlinear optical ..... between the optic axes and optic sign of the biaxial crystal.

  2. Crystal Systems.

    Science.gov (United States)

    Schomaker, Verner; Lingafelter, E. C.

    1985-01-01

    Discusses characteristics of crystal systems, comparing (in table format) crystal systems with lattice types, number of restrictions, nature of the restrictions, and other lattices that can accidently show the same metrical symmetry. (JN)

  3. Post mortem analysis of a JET quartz microbalance system

    Energy Technology Data Exchange (ETDEWEB)

    Esser, H.G. [Association EURATOM-Forschungszentrum Juelich, IPP, D-52425, Juelich (Germany)]. E-mail: h.g.esser@fz-juelich.de; Philipps, V. [Association EURATOM-Forschungszentrum Juelich, IPP, D-52425, Juelich (Germany); Wienhold, P. [Association EURATOM-Forschungszentrum Juelich, IPP, D-52425, Juelich (Germany); Sugiyama, K. [Department of Nuclear Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan); Kreter, A. [Association EURATOM-Forschungszentrum Juelich, IPP, D-52425, Juelich (Germany); Coad, J.P. [UKAEA/EURATOM Fusion Association, Culham Science Centre, Abingdon (United Kingdom); Tanabe, T. [Department of Nuclear Engineering, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603 (Japan)

    2007-06-15

    In the year 2001, a quartz microbalance system (QMB) was installed in the remote area of the inner JET divertor to investigate in situ material erosion and redeposition processes. When removed in 2004, the system was found to be coated all over with carbon deposits. The deposit on the quartz oscillator and the outer and inner housing was analysed by various methods, as SIMS (secondary ion mass spectroscopy), stylus depth profilometry, EPMA (electron probe microanalysis), TIPT (Tritium imaging plate technique) and colorimetry and compared to the frequency change of the quartz. The layer thickness was determined to 1.85 {+-} 0.1 {mu}m in average on an area of 0.95 cm{sup 2} which has to be related to the equivalent of 1.77 x 10{sup -4} g measured from the frequency change of 23 640 Hz. This corresponds to a carbon areal density of 9.3 x 10{sup 18} C atoms/cm{sup 2}. Significant deposition was found also on the surfaces inside the QMB housing which can only be understood if reflection and low sticking is assumed for a high fraction of particles.

  4. Pressure solution of minerals in quartz-type buffer materials

    International Nuclear Information System (INIS)

    Erlstroem, M.

    1986-12-01

    Two samples, pure quartz sand and a sand-bentonite (10%) mixture, were tested under conditions of high pressure (200 bar) and temperature (115 0 C). The experiment was carried out over a period of 70 days. A series of thin slides were prepared on a resin embedded sample at the end of the test period. A microscopical study was performed as to obtain data concerning the effects of pressure and temperature. It showed that no pressure solution had taken place in the pure quartz sand. However, the individual grains had been severely fractured, thus causing significant internal sedimentation. The mixed sample showed that the clay component coated the quartz grains and significantly decreased the effect of stress in the grains by having a cushioning effect. Relative grain movement was facilitated by the clay, by which the grains rotated and slipped into stable positions with large contact areas and low contact stresses. This probably minimized pressure solution. However, a few contact regions indicated the presence of precipitated silica. The investigation shows no definite evidence of pressure solution after an experiment duration of 70 days. Since the effect of solution may be time dependent at the applied temperature, it is recommended that further experiments be conducted at higher effective and porewater pressures but still at 115 0 C. (orig.)

  5. Experiment study of a quartz tube falling particle receiver

    Institute of Scientific and Technical Information of China (English)

    Tianjian WANG; Fengwu BAI; Shunzhou CHU; Xiliang ZHANG; Zhifeng WANG

    2017-01-01

    This paper presents an experimental evaluation of a specially designed falling particle receiver.A quartz tube was used in the design,with which the particles would not be blown away by wind.Concentrated solar radiation was absorbed and converted into thermal energy by the solid particles flowed inside the quartz tube.Several experiments were conducted to test the dynamic thermal performance of the receiver on solar furnace system.During the experiments,the maximum particle temperature rise is 212℃,with an efficiency of 61.2%,which shows a good thermal performance with a falling distance of 0.2 m in a small scale particle receiver.The average outlet particle temperature is affected by direct normal irradiance (DNI) and other factors such as wind speed.The solid particles obtain a larger viscosity with a higher temperature while smaller solid particles are easier to get stuck in the helix quartz tube.The heat capacity of the silicon carbide gets larger with the rise of particle temperature,because as the temperature of solid particles increases,the temperature rise of the silicon carbide decreases.

  6. Natural quartz TL property and similarity in Piper nigrum L

    International Nuclear Information System (INIS)

    Guzman A, S.; Cruz Z, E.; Furetta, C.; Brown, F.; Barboza F, M.

    2009-10-01

    Quartz is a mineral abundant in nature and can provide information thermoluminescent (TL), and also is located in the mineral fraction of some herbs and spices consumed. It is present the analysis of the TL properties of a sample of natural quartz rock and compared with those obtained from the fraction of Piper nigrum L. poly mineral when they were exposed to 60 Co gamma radiation. The poly minerals of Piper nigrum L. were analyzed by X-ray diffraction, where the quartz was found as a major component. They separated in different particle sizes (10, 53, 74 and 149 μm). The samples were irradiated at relatively low doses (1-500 Gy) and high (0.1-40 kGy) in order to determine the linearity of the TL emission as a function of the dose and the analysis of glow curves. Also there was the fading of the TL signal, the effect of ultra violet light. The reproducibility of the TL signal in the samples indicates that a smaller particle size gives better TL signal. (author)

  7. Usability of VTL from natural quartz grains for retrospective dosimetry

    International Nuclear Information System (INIS)

    Fujita, H.; Hashimoto, T.

    2007-01-01

    To develop retrospective dosimetry of unexpected radiation accident, basic studies on violet thermoluminescence (VTL) phenomena were conducted using natural quartz grains. All VTL glow curves of as-received samples did not exhibit peaks <250 deg. C, although for artificially irradiated quartz samples there were VTL peaks in the temperature region <250 deg. C. Therefore, accident doses could be estimated without the interference of naturally accumulated doses by VTL measurements from natural quartz. The mean lives of VTL were evaluated by the various heating rates method and the range of values was found to be between some days and ten thousands of years depending on each peak. Especially, the mean life of VTL peak at 200 deg. C was years order. Furthermore, the lower detection limit was calculated to be tens of mGy from the response curve. This value was lower than that of other methods such as ESR dosimetry. From these results, we conclude that VTL dosimetry can be preferred for accidental evaluation. (authors)

  8. Analysis of optical bleaching of OSL signal in sediment quartz

    International Nuclear Information System (INIS)

    Przegiętka, K.R.; Chruścińska, A.

    2013-01-01

    The aim of this work was to study the effect of the quality of optical bleaching on the results of OSL (Optically Stimulated Luminescence) dating method. The large aliquots of coarse quartz grains extracted from fluvial deposit were used in the study. The poor, medium and good bleaching were simulated in laboratory with help of Blue LED light source in series of experiments. Then the samples were irradiated with a common laboratory dose. The equivalent doses (DE) were measured by the help of standard Single Aliquot Regeneration (SAR) technique, but obtained DE distributions are analyzed in a new way. The method for recognizing and compensating for partial bleaching is proposed. The conclusions for dating sediment quartz samples are presented and discussed. -- Highlights: ► Bleaching experiments on sediment quartz are performed. ► Blue LED light source incorporated in luminescence reader is used. ► New analysis of data measured by standard SAR OSL technique is proposed. ► The results are promising for recognizing and compensating for partial bleaching

  9. Reconstruction of thermally quenched glow curves in quartz

    International Nuclear Information System (INIS)

    Subedi, Bhagawan; Polymeris, George S.; Tsirliganis, Nestor C.; Pagonis, Vasilis; Kitis, George

    2012-01-01

    The experimentally measured thermoluminescence (TL) glow curves of quartz samples are influenced by the presence of the thermal quenching effect, which involves a variation of the luminescence efficiency as a function of temperature. The real shape of the thermally unquenched TL glow curves is completely unknown. In the present work an attempt is made to reconstruct these unquenched glow curves from the quenched experimental data, and for two different types of quartz samples. The reconstruction is based on the values of the thermal quenching parameter W (activation energy) and C (a dimensionless constant), which are known from recent experimental work on these two samples. A computerized glow-curve deconvolution (CGCD) analysis was performed twice for both the reconstructed and the experimental TL glow curves. Special attention was paid to check for consistency between the results of these two independent CGCD analyses. The investigation showed that the reconstruction attempt was successful, and it is concluded that the analysis of reconstructed TL glow curves can provide improved values of the kinetic parameters E, s for the glow peaks of quartz. This also leads to a better evaluation of the half-lives of electron trapping levels used for dosimetry and luminescence dating.

  10. Apatite-brannerite-pitchblende association in hydrothermal quartz veins

    International Nuclear Information System (INIS)

    Brodin, B.V.; Mel'nikova, A.M.; Osipov, B.S.; Pavlov, E.G.

    1976-01-01

    A study into the vein quartz mineralization confined to the tectonic zones of crush and silicification in sedimentary-igneous rocks of the lower Paleozoic has been made. The physicochemical characteristics of minerals were studied by way of optical and electron microscopy, chemical, laser-microspectral and X-ray structural analyses, microprobing and alpha-microradiography. 3 mineral associations have been discriminated, representative of the sequence of hydrothermal mineralization. An unusual parogenesis of pitchblende and brannerite with apatite, xenotime and more recent goethite has been revealed. The results are indicative of a medium-low-temperature hydrothermal process occurring at the final stages of formation of uraniferrous quartz veins. By composition and mineralization sequence, the latters are close to low- and medium-temperature uranium-quartz-chlorite-hydromica formations with apatite, coffinite, brannerite and pitchblende. The weak initial metamictization of goethite in veins 80 to 100 million years old is due to the radioactive effect of the submicroscopic radioactive mineral impurity on the crystalline lattice

  11. Surface impedance of epitaxial films Y-Ba-Cu-O in short wave region of range millimetric

    International Nuclear Information System (INIS)

    Vojnovskij, I.V.; Pustyl'nik, O.D.; Boguslavskij, Yu.M.; Shapovalov, A.P.

    1992-01-01

    Epitaxial Y-Ba-Cu-O films on MgO substrate with perfect crystal structure are obtained due to nonaxial magnetron HF-spraying. Temperature dependence of the surface impedance of the films within 66 and 134 GHz frequency is studied. The obtained value of residual surface resistance within 134 GHz frequency (60 mohm) confirms high quality of the films

  12. SPHERICAL MICROPARTICLES FROM GOLD–BEARING QUARTZ VEINS OF THE IROKINDA DEPOSIT, WESTERN TRANSBAIKALIA

    Directory of Open Access Journals (Sweden)

    A. V. Tatarinov

    2016-01-01

    .The consequence of metamorphism, i.e. deformational or mechano-chemical transformations of rocks in Irokinda, as well as the autochthon (the rock bed of the Kelyano-Irokinda belt, is the gas-water (‘hydrothermal’ system capable of forming the spherical ore particles with low-temperature mineral rims.The main feature of the structure of the spherical microparticles in Irokinda is a sharp contrast of the crystallization conditions of the metal nodes and their rims. Similar conditions leading to formation of contrasting mineral associations, that are similar in compositions to the discussed spherules, are characteristic of the gas-water-lithoclastitic and gas-water stages of mud volcanoes. For these stages, we suggest the cavitation mechanism of formation of spherical metal particles of Fe, Fe–Cr and other compositions, which is accompanied by combustion (pyrogenic melt and pyrolysis of hydrocarbon components of the fluid. This mechanism, with the exception of the origin of the melt (in this case, of the friction type seems to most closely correspond to the actual data.  The spheroids are likely to have formed in the pre-ore stage of formation of the quartz veins.The high-temperature metal spherical microparticles revealed in our study can be regarded as specific indicators showing conditions in which the ore-forming system of the dynamo-metamorphic type was functioning to produce gold mineralization on the Irokinda deposit. The structure and composition of these microparticles differ from those of the microspherules from other gold deposits in Transbaikalia (black shale formation in Sukhoi Log, and low–sulphide gold–quartz ore formation in Pervenets, which also belong to the dynamogenic genetic type. However, the ore-forming systems of the compared deposits have two common factors that contribute to formation of spherical microparticles – high tectonic activity manifested by repeated (impulse-type tectonic movements, and the associated unstable pressure conditions. The

  13. Creep of quartz by dislocation and grain boundary processes

    Science.gov (United States)

    Fukuda, J. I.; Holyoke, C. W., III; Kronenberg, A. K.

    2015-12-01

    Wet polycrystalline quartz aggregates deformed at temperatures T of 600°-900°C and strain rates of 10-4-10-6 s-1 at a confining pressure Pc of 1.5 GPa exhibit plasticity at low T, governed by dislocation glide and limited recovery, and grain size-sensitive creep at high T, governed by diffusion and sliding at grain boundaries. Quartz aggregates were HIP-synthesized, subjecting natural milky quartz powder to T=900°C and Pc=1.5 GPa, and grain sizes (2 to 25 mm) were varied by annealing at these conditions for up to 10 days. Infrared absorption spectra exhibit a broad OH band at 3400 cm-1 due to molecular water inclusions with a calculated OH content (~4000 ppm, H/106Si) that is unchanged by deformation. Rate-stepping experiments reveal different stress-strain rate functions at different temperatures and grain sizes, which correspond to differing stress-temperature sensitivities. At 600-700°C and grain sizes of 5-10 mm, flow law parameters compare favorably with those for basal plasticity and dislocation creep of wet quartzites (effective stress exponents n of 3 to 6 and activation enthalpy H* ~150 kJ/mol). Deformed samples show undulatory extinction, limited recrystallization, and c-axis maxima parallel to the shortening direction. Similarly fine-grained samples deformed at 800°-900°C exhibit flow parameters n=1.3-2.0 and H*=135-200 kJ/mol corresponding to grain size-sensitive Newtonian creep. Deformed samples show some undulatory extinction and grain sizes change by recrystallization; however, grain boundary deformation processes are indicated by the low value of n. Our experimental results for grain size-sensitive creep can be compared with models of grain boundary diffusion and grain boundary sliding using measured rates of silicon grain boundary diffusion. While many quartz mylonites show microstructural and textural evidence for dislocation creep, results for grain size-sensitive creep may apply to very fine-grained (<10 mm) quartz mylonites.

  14. Amplifier Module for 260-GHz Band Using Quartz Waveguide Transitions

    Science.gov (United States)

    Padmanabhan, Sharmila; Fung, King Man; Kangaslahti, Pekka P.; Peralta, Alejandro; Soria, Mary M.; Pukala, David M.; Sin, Seth; Samoska, Lorene A.; Sarkozy, Stephen; Lai, Richard

    2012-01-01

    Packaging of MMIC LNA (monolithic microwave integrated circuit low-noise amplifier) chips at frequencies over 200 GHz has always been problematic due to the high loss in the transition between the MMIC chip and the waveguide medium in which the chip will typically be used. In addition, above 200 GHz, wire-bond inductance between the LNA and the waveguide can severely limit the RF matching and bandwidth of the final waveguide amplifier module. This work resulted in the development of a low-loss quartz waveguide transition that includes a capacitive transmission line between the MMIC and the waveguide probe element. This capacitive transmission line tunes out the wirebond inductance (where the wire-bond is required to bond between the MMIC and the probe element). This inductance can severely limit the RF matching and bandwidth of the final waveguide amplifier module. The amplifier module consists of a quartz E-plane waveguide probe transition, a short capacitive tuning element, a short wire-bond to the MMIC, and the MMIC LNA. The output structure is similar, with a short wire-bond at the output of the MMIC, a quartz E-plane waveguide probe transition, and the output waveguide. The quartz probe element is made of 3-mil quartz, which is the thinnest commercially available material. The waveguide band used is WR4, from 170 to 260 GHz. This new transition and block design is an improvement over prior art because it provides for better RF matching, and will likely yield lower loss and better noise figure. The development of high-performance, low-noise amplifiers in the 180-to- 700-GHz range has applications for future earth science and planetary instruments with low power and volume, and astrophysics array instruments for molecular spectroscopy. This frequency band, while suitable for homeland security and commercial applications (such as millimeter-wave imaging, hidden weapons detection, crowd scanning, airport security, and communications), also has applications to

  15. Experimental deformation in sandstone, carbonates and quartz aggregate

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Cecilia See Nga [Stony Brook Univ., NY (United States)

    2015-05-01

    The first part of my thesis is mainly focused on the effect of grain size distribution on compaction localization in porous sandstone. To identify the microstructural parameters that influence compaction band formation, I conducted a systematic study of mechanical deformation, failure mode and microstructural evolution in Bleurswiller and Boise sandstones, of similar porosity (~25%) and mineralogy but different sorting. Discrete compaction bands were observed to develop over a wide range of pressure in the Bleurswiller sandstone that has a relatively uniform grain size distribution. In contrast, compaction localization was not observed in the poorly sorted Boise sandstone. My results demonstrate that grain size distribution exerts important influence on compaction band development, in agreement with recently published data from Valley of Fire and Buckskin Gulch, as well as numerical studies. The second part aimed to improve current knowledge on inelastic behavior, failure mode and brittle-ductile transition in another sedimentary rock, porous carbonates. A micritic Tavel (porosity of ~13%) and an allochemical Indiana (~18%) limestones were deformed under compaction in wet and dry conditions. At lower confining pressures, shear localization occurred in brittle faulting regime. Through transitional regime, the deformation switched to cataclastic flow regime at higher confining pressure. Specifically in the cataclastic regime, the (dry and wet) Tavel and dry Indiana failed by distributed cataclastic flow, while in contrast, wet Indiana failed as compaction localization. My results demonstrate that different failure modes and mechanical behaviors under different deformation regimes and water saturation are fundamental prior to any geophysical application in porous carbonates. The third part aimed to focus on investigating compaction on quartz aggregate starting at low (MPa) using X-ray diffraction. We report the diffraction peak evolution of quartz with increasing

  16. VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS

    Directory of Open Access Journals (Sweden)

    V. I. Bankov

    2016-01-01

    Full Text Available Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF. The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L / X(C was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L and X (C parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L / X (C.Conclusion. Contactless method of biological

  17. Laboratory scale tests of electrical impedence tomography

    International Nuclear Information System (INIS)

    Binley, A; Daily, W; LaBredcque, D; Ramirez, A.

    1998-01-01

    Electrical impedance tomographs (magnitude and phase) of known, laboratory-scale targets are reported. Three methods are used to invert electrical impedance data and their tomographs compared. The first method uses an electrical resistance tomography (ERT) algonthm (designed for DC resistivity inversion) to perform impedance magnitude inversion and a linearized perturbation approach (PA) to invert the imaginary part. The second approximate method compares ERT magnitude inversions at two frequencies and uses the frequency effect (FE) to compute phase tomographs. The third approach, electrrcal impedance tomography (EIT), employs fully complex algebra to account for the real and imaginary components of electrical impedance data. The EIT approach provided useful magnitude and phase images for the frequency range of 0.0625 to 64 Hz; images for higher frequencies were not reliable. Comparisons of the ERT and EIT magnitude images show that both methods provided equivalent results for the water blank, copper rod and PVC rod targets. The EIT magnitude images showed better spatial resolutron for a sand-lead mixture target. Phase images located anomalies of both high and low contrast IP and provided better spatial resolution than the magnitude images. When IP was absent from the data, the EIT algorithm reconstructed phase values consistent with the data noise levels

  18. Broadband impedance of the NESTOR storage ring

    International Nuclear Information System (INIS)

    Androsov, V.P.; Gladkikh, P.I.; Gvozd, A.M.; Karnaukhov, I.M.; Telegin, Yu.N.

    2011-01-01

    The contributions from lossy and inductive vacuum chamber components to the broadband impedance of the NESTOR storage ring are obtained by using both low-frequency analytical approaches and computer simulations. As was expected considering the small ring circumference (15.44m), the main contributions both to the longitudinal impedance Z || /n and the loss factor k loss come from the RF-cavity. Cavity impedance was also estimated with CST Microwave Studio (CST Studio Suite TM 2006) by simulating coaxial wire method commonly used for impedance measurements. Both estimates agree well. Finally, we performed the simulations of a number of inductive elements with CST Particle Studio 2010 by using wake field solver. We have also evaluated the bunch length in NESTOR taking the conservative estimate of 3 Ohm for the ring broadband impedance and have found that the bunch length s z = 0.5 cm could be obtained in steady state operation mode for the designed bunch current of 10 mA and RF-voltage of 250 kV.

  19. Impedance Spectroscopy of Dielectrics and Electronic Conductors

    DEFF Research Database (Denmark)

    Bonanos, Nikolaos; Pissis, Polycarpos; Macdonald, J. Ross

    2013-01-01

    Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property, such as admi......Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property......, such as admittance or dielectric constant - as a function of frequency and comparing the results with expectations based on physical, chemical, and microstructural models. This article reviews the principles and practical aspects of the technique, the representations of the results, the analysis of data......, and procedures for the correction of measurement errors. The applications of impedance spectroscopy are illustrated with examples from electroceramics and polymer-based dielectric systems. The way in which the technique is applied to the two classes of materials is compared with reference to the different models...

  20. Rf Discharge Impedance Measurements Using a New Method to Determine the Stray Impedances

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.; Hoog, de F.J.

    1999-01-01

    The impedance of a capacitively coupled radio frequency discharge in a tubular fluorescent lamp filled with neon and mercury is measured. The stray impedances in the electrical network are determined using a new method that requires no extra instruments. The reflection of power is used to determine

  1. Elimination of the Respiratory Effect on the Thoracic Impedance Signal with Whole-body Impedance Cardiography

    Czech Academy of Sciences Publication Activity Database

    Jurák, Pavel; Halámek, Josef; Vondra, Vlastimil; Viščor, Ivo; Lipoldová, J.; Plachý, M.

    2010-01-01

    Roč. 37, - (2010), s. 1051-1054 ISSN 0276-6574 R&D Projects: GA AV ČR IAA200650801 Institutional research plan: CEZ:AV0Z20650511 Keywords : respiratory effect * thoracic impedance signal * impedance cardiography Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://cinc.mit.edu/archives/2010/pdf/1051.pdf

  2. Monomial Crystals and Partition Crystals

    Science.gov (United States)

    Tingley, Peter

    2010-04-01

    Recently Fayers introduced a large family of combinatorial realizations of the fundamental crystal B(Λ0) for ^sln, where the vertices are indexed by certain partitions. He showed that special cases of this construction agree with the Misra-Miwa realization and with Berg's ladder crystal. Here we show that another special case is naturally isomorphic to a realization using Nakajima's monomial crystal.

  3. The stability of PEMFC electrodes : platinum dissolution vs potential and temperature investigated by quartz crystal microbalance

    NARCIS (Netherlands)

    Dam, V.A.T.; Bruijn, de F.A.

    2007-01-01

    The stability of platinum in proton exchange membrane fuel cell (PEMFC) electrodes has been investigated by determining the dissolution of platinum from a thin platinum film deposited on a gold substrate in 1 M HClO4 at different temperatures ranging between 40 and 80°C and potentials between 0.85

  4. Determination of the dopant weight fraction in polyaniline films using a quartz-crystal microbalance

    Czech Academy of Sciences Publication Activity Database

    Ayad, M. M.; Zaki, E. A.; Stejskal, Jaroslav

    2007-01-01

    Roč. 515, č. 23 (2007), s. 8381-8385 ISSN 0040-6090 R&D Projects: GA AV ČR IAA4050313 Institutional research plan: CEZ:AV0Z40500505 Keywords : dopant weight fraction * polyaniline * polyaniline film Subject RIV: BM - Solid Matter Physics ; Magnetism Impact factor: 1.693, year: 2007

  5. Ab initio modeling of fused silica, crystal quartz, and water Raman spectra

    Czech Academy of Sciences Publication Activity Database

    Dračínský, Martin; Benda, Ladislav; Bouř, Petr

    2011-01-01

    Roč. 512, č. 13 (2011), s. 54-59 ISSN 0009-2614 R&D Projects: GA ČR GAP208/11/0105; GA MŠk(CZ) LH11033 Grant - others:GA MŠk(CZ) 2B08021 Program:2B Institutional research plan: CEZ:AV0Z40550506 Keywords : fused silica * Raman spectroscopy * Car -Parrinello molecular dynamics Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 2.337, year: 2011

  6. Performance comparison of Rayleigh and STW modes on quartz crystal for strain sensor application

    Energy Technology Data Exchange (ETDEWEB)

    Fu, Chen; Lee, Ki Jung; Lee, Keekeun; Yang, Sang Sik, E-mail: ssyang@ajou.ac.kr [Department of Electrical and Computer Engineering, Ajou University, Suwon 442-749 (Korea, Republic of); Eun, Kyongtae; Choa, Sung-Hoon [Nano-IT Fusion Program, Seoul National University of Science and Technology, Seoul 139-743 (Korea, Republic of)

    2016-07-14

    In this study, we compare two kinds of strain sensors based on Rayleigh wave and surface transverse wave (STW) modes, respectively. First, we perform a strain-and-stress analysis using the finite element method, and we consider the contribution to a surface acoustic wave (SAW) velocity shift. Prior to fabrication, we use a coupling-of-modes model to simulate and optimize two-port SAW resonators for both modes. We use a network analyzer to measure and characterize the two devices. Further, we perform an experiment using a strain-testing system with a tapered cross-section cantilever beam. The experimental results show that the ratio of the frequency shift to the strain for the Rayleigh wave mode is −1.124 ppm/με in the parallel direction and 0.109 ppm/με in the perpendicular direction, while the corresponding values for the STW mode are 0.680 ppm/με and 0.189 ppm/με, respectively.

  7. Raman and micro-thermometric investigation of the fluid inclusions in quartz in a gold-rich formation from Lepaguare mining district (Honduras, Central America).

    Science.gov (United States)

    Bersani, D; Salvioli-Mariani, E; Mattioli, M; Menichetti, M; Lottici, P P

    2009-08-01

    Fluid inclusions in the quartz crystals present in gold-rich veins from central Honduras have been studied by means of micro-thermometry and micro-Raman spectroscopy in order to provide information on the physico-chemical conditions and chemical composition of the mineralizing fluids. The use of a confocal micro-Raman apparatus allowed to obtain information on the fluid composition, in particular on the gas phase, minimizing the contributions of the host matrix to the Raman signal. The samples studied were collected from an area (Lepaguare mining district, Northern-Central Honduras) rich in ore deposits due to the Cenozoic magmatic activity, where the gold and sulphide mineralization is connected with a system of quartz veins (few decimetres thick) occurring in low-grade metamorphic rocks and produced by hydrothermal fluids. The quartz crystals present in the gold-rich veins often contain fluid inclusions. Four types of fluid inclusions have been observed, but their assemblage in the same clusters and fracture systems, as well as their comparable salinity and homogenization data, suggest that they have the same origin. Micro-thermometry and Raman spectroscopy provide a composition of the mineralizing fluids attributable to the system H(2)O-NaCl-KCl-CO(2)-CH(4), with temperature and pressure intervals of 210-413 degrees C and 1050-3850 bar, respectively. These data agree with an epigenetic origin of the gold deposit (depth < 6 km) related to granitoid or granodiorite intrusions associated to orogenic environments.

  8. A natural example of fluid-mediated brittle-ductile cyclicity in quartz veins from Olkiluoto Island, SW Finland

    Science.gov (United States)

    Marchesini, Barbara; Garofalo, Paolo S.; Viola, Giulio; Mattila, Jussi; Menegon, Luca

    2017-04-01

    recognize three distinct episodes of ductile deformation alternating with at least three brittle episodes. Preliminary fluid inclusion data show that, during crystallization and brittle-viscous deformation, quartz crystals hosted homogeneous and heterogeneous (boiling) aqueous fluids with a large salinity (11.7-0 wt% NaCleq) and Thtot (410-200 °C) range. Boiling occurred at 200-260 °C. Variations of fluid temperature and density (hence, viscosity) may thus have induced localized cyclic switches between brittle and ductile deformation in quartz, with implications on the bulk regional crustal strength. Preliminary EBSD analysis also supports the hypothesis of cyclic switches between brittle and viscous deformation.

  9. Impedance measurements of components for the ALS

    International Nuclear Information System (INIS)

    Corlett, J.N.; Rimmer, R.A.

    1993-05-01

    The high current and short bunch length of the ALS beam make the machine susceptible to beam instabilities over a frequency range extending to 13 GHz and beyond. All components of the storage ring have been carefully designed to minimize the impedance presented to the beam, and assemblies have been laid out to avoid resonant enclosures between components. Novel bellows shields allowing considerable mechanical movement while maintaining a low impedance are described. Results are presented of impedance measurements of ALS components and assemblies of components, using a precision coaxial wire technique in frequency domain, extending to frequencies beyond cut-off. All measurements were performed at the Lambertson Beam Electrodynamics Laboratory of the Center for Beam Physics at LBL

  10. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Hofmann, A.; Jowett, J.; Lockman, W.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.

    1988-05-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. The results showed that, although the gross longitudinal impedance had indeed been reduced, the 'capacitive' component had also decreased relative to the 'inductive'--to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded 'capacitor' cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained. 7 refs., 6 figs

  11. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.; Hofmann, A.; Jowett, J.; Lockman, W.

    1988-01-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. This paper shows that although the gross longitudinal impedance had indeed been reduced, the capacitive component had also decreased relative to the inductive - to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded capacitor cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained

  12. Wavelet analysis of the impedance cardiogram waveforms

    Science.gov (United States)

    Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.

    2012-12-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  13. Wavelet analysis of the impedance cardiogram waveforms

    International Nuclear Information System (INIS)

    Podtaev, S; Stepanov, R; Dumler, A; Chugainov, S; Tziberkin, K

    2012-01-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt) max ) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  14. Coupling slots without shunt impedance drop

    International Nuclear Information System (INIS)

    Balleyguier, P.

    1996-01-01

    It is well known that coupling slots between adjacent cells in a π-mode structure reduce shunt impedance per unit length with respect to single cell cavities. To design optimized coupling slots, one has to answer the following question: for a given coupling factor, what shape, dimension, position and number of slots lead to the lowest shunt impedance drop? A numerical study using the 3D code MAFIA has been carried out. The aim was to design the 352 MHz cavities for the high intensity proton accelerator of the TRISPAL project. The result is an unexpected set of four 'petal' slots. Such slots should lead to a quasi-negligible drop in shunt impedance: about -1% on average, for particle velocity from 0.4 c to 0.8 c. (author)

  15. Electrochemical Impedance Spectroscopy Of Metal Alloys

    Science.gov (United States)

    Macdowell, L. G.; Calle, L. M.

    1993-01-01

    Report describes use of electrochemical impedance spectroscopy (EIS) to investigate resistances of 19 alloys to corrosion under conditions similar to those of corrosive, chloride-laden seaside environment of Space Transportation System launch site. Alloys investigated: Hastelloy C-4, C-22, C-276, and B-2; Inconel(R) 600, 625, and 825; Inco(R) G-3; Monel 400; Zirconium 702; Stainless Steel 304L, 304LN, 316L, 317L, and 904L; 20Cb-3; 7Mo+N; ES2205; and Ferralium 255. Results suggest electrochemical impedance spectroscopy used to predict corrosion performances of metal alloys.

  16. Study of Body Composition by Impedance Analysis

    Science.gov (United States)

    González-Solís, J. L.; Vargas-Luna, M.; Sosa-Aquino, M.; Bernal-Alvarado, J.; Gutiérrez-Juárez, G.; Huerta-Franco, R.; Sanchis-Sabater, A.

    2002-08-01

    This work presents a set of impedance measurements and preliminary results on the analysis of body composition using impedance spectroscopy. This study is made using a pork meat sample and spectra from fat and flesh region were independently obtained using the same electrodes array. From these measurements, and theoretical considerations, it is possible to explain the behavior of the composite sample flesh-fat-flesh and, fitting the electrical parameters of the model, it shows the plausibility of a physical and quantitative application to human corporal composition.

  17. Real-Time Thevenin Impedance Computation

    DEFF Research Database (Denmark)

    Sommer, Stefan Horst; Jóhannsson, Hjörtur

    2013-01-01

    operating state, and strict time constraints are difficult to adhere to as the complexity of the grid increases. Several suggested approaches for real-time stability assessment require Thevenin impedances to be determined for the observed system conditions. By combining matrix factorization, graph reduction......, and parallelization, we develop an algorithm for computing Thevenin impedances an order of magnitude faster than previous approaches. We test the factor-and-solve algorithm with data from several power grids of varying complexity, and we show how the algorithm allows realtime stability assessment of complex power...

  18. Thermal dependence of luminescence lifetimes and radioluminescence in quartz

    Energy Technology Data Exchange (ETDEWEB)

    Pagonis, V., E-mail: vpagonis@mcdaniel.edu [McDaniel College, Physics Department, Westminster, MD 21157 (United States); Chithambo, M.L. [Department of Physics and Electronics, Rhodes University, PO BOX 94, Grahamstown 6140 (South Africa); Chen, R. [Raymond and Beverly Sackler School of Physics and Astronomy, Tel-Aviv University, Tel-Aviv 69978 (Israel); Chruścińska, A. [Institute of Physics, Nicholas Copernicus University, 87-100 Toruń (Poland); Fasoli, M. [Department of Materials Science, University of Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Li, S.H. [Department of Earth Sciences, The University of Hong Kong (Hong Kong); Martini, M. [Department of Materials Science, University of Milano-Bicocca, Via Cozzi 53, 20125 Milano (Italy); Ramseyer, K. [Institut für Geologie, Baltzerstrasse 1-3, 3012 Bern (Switzerland)

    2014-01-15

    During time-resolved optical stimulation experiments (TR-OSL), one uses short light pulses to separate the stimulation and emission of luminescence in time. Experimental TR-OSL results show that the luminescence lifetime in quartz of sedimentary origin is independent of annealing temperature below 500 °C, but decreases monotonically thereafter. These results have been interpreted previously empirically on the basis of the existence of two separate luminescence centers L{sub H} and L{sub L} in quartz, each with its own distinct luminescence lifetime. Additional experimental evidence also supports the presence of a non-luminescent hole reservoir R, which plays a critical role in the predose effect in this material. This paper extends a recently published analytical model for thermal quenching in quartz, to include the two luminescence centers L{sub H} and L{sub L}, as well as the hole reservoir R. The new extended model involves localized electronic transitions between energy states within the two luminescence centers, and is described by a system of differential equations based on the Mott–Seitz mechanism of thermal quenching. It is shown that by using simplifying physical assumptions, one can obtain analytical solutions for the intensity of the light during a TR-OSL experiment carried out with previously annealed samples. These analytical expressions are found to be in good agreement with the numerical solutions of the equations. The results from the model are shown to be in quantitative agreement with published experimental data for commercially available quartz samples. Specifically the model describes the variation of the luminescence lifetimes with (a) annealing temperatures between room temperature and 900 °C, and (b) with stimulation temperatures between 20 and 200 °C. This paper also reports new radioluminescence (RL) measurements carried out using the same commercially available quartz samples. Gaussian deconvolution of the RL emission spectra was

  19. A quartz Cherenkov detector for polarimetry at the ILC

    International Nuclear Information System (INIS)

    Vauth, Annika

    2014-09-01

    At the proposed International Linear Collider (ILC), the use of polarised electron and positron beams is a key ingredient of the physics program. A measurement of the polarisation with a yet unprecedented precision of δP / P =0.25% is required. To achieve this, Compton polarimeter measurements in front of and behind the collision point are foreseen. In this thesis, a novel concept for a detector for ILC polarimetry is introduced to eliminate one of the dominating systematics limiting the previous best measurement of beam polarisation: a detector using quartz as Cherenkov medium could increase the tolerance against non-linear photodetector responses. The high refractive index of quartz results in a higher Cherenkov light yield compared to conventional Cherenkov gases. This could allow single-peak resolution in the Cherenkov photon spectra produced by the Compton electrons at the polarimeters. The detailed simulation studies presented in this work imply that such single-peak resolution is possible. Considerations for the choice of a suitable detector geometry are discussed. A four-channel prototype has been constructed and successfully operated in a first testbeam campaign at the DESY testbeam, confirming simulation predictions. Although further studies have to be considered to quantify all aspects of the detector response, the findings of the analysis of the data from the first testbeam are promising with regards to reaching the desired light yield. In the final part of this thesis, the application of a detector concept allowing single-peak resolution to the polarisation measurement at the ILC is examined. Two of the main sources of systematic uncertainties on the polarimeter measurements are detector non-linearities and misalignments. The performance of the suggested quartz detector concept in Monte Carlo studies promises a control of these systematics which meets the precision requirements for ILC polarimetry.

  20. Study of quartz lascas properties for technological applications

    International Nuclear Information System (INIS)

    Hummel, D.C.A.; Shinohara, A.H.; Torikai, D.; Suzuki, C.K.

    1988-01-01

    This paper describes a fundamental properties of Brasilian quartz lascas characterized by x-ray diffraction topography and goniometry, density and ultrasonic attenuation measurements, optical inspectoscopy, optical microscopy and impurity analysis by ASS (Al,Fe,Na,K,Li,Ca,Mn,Mg,Cr and Cu). The results were discussed with the correlation with nominal lascas graded as ''Ist'', ''mix'',''2nd'',''3rd'' and ''4th'' made by visual observation taking in consideration the transparency. The samples were collected from the proper mines deposited lascas. The main brazilian producted states are Minas Gerais, Bahia and Goias. (author) [pt