WorldWideScience

Sample records for quantitative intact specimen

  1. Quantitative X-ray microanalysis of biological specimens

    International Nuclear Information System (INIS)

    Roomans, G.M.

    1988-01-01

    Qualitative X-ray microanalysis of biological specimens requires an approach that is somewhat different from that used in the materials sciences. The first step is deconvolution and background subtraction on the obtained spectrum. The further treatment depends on the type of specimen: thin, thick, or semithick. For thin sections, the continuum method of quantitation is most often used, but it should be combined with an accurate correction for extraneous background. However, alternative methods to determine local mass should also be considered. In the analysis of biological bulk specimens, the ZAF-correction method appears to be less useful, primarily because of the uneven surface of biological specimens. The peak-to-local background model may be a more adequate method for thick specimens that are not mounted on a thick substrate. Quantitative X-ray microanalysis of biological specimens generally requires the use of standards that preferably should resemble the specimen in chemical and physical properties. Special problems in biological microanalysis include low count rates, specimen instability and mass loss, extraneous contributions to the spectrum, and preparative artifacts affecting quantitation. A relatively recent development in X-ray microanalysis of biological specimens is the quantitative determination of local water content

  2. Toward best practices in data processing and analysis for intact biotherapeutics by MS in quantitative bioanalysis.

    Science.gov (United States)

    Kellie, John F; Kehler, Jonathan R; Karlinsey, Molly Z; Summerfield, Scott G

    2017-12-01

    Typically, quantitation of biotherapeutics from biological matrices by LC-MS is based on a surrogate peptide approach to determine molecule concentration. Recent efforts have focused on quantitation of the intact protein molecules or larger mass subunits of monoclonal antibodies. To date, there has been limited guidance for large or intact protein mass quantitation for quantitative bioanalysis. Intact- and subunit-level analyses of biotherapeutics from biological matrices are performed at 12-25 kDa mass range with quantitation data presented. Linearity, bias and other metrics are presented along with recommendations made on the viability of existing quantitation approaches. This communication is intended to start a discussion around intact protein data analysis and processing, recognizing that other published contributions will be required.

  3. Quantitative proteomic analysis of intact plastids.

    Science.gov (United States)

    Shiraya, Takeshi; Kaneko, Kentaro; Mitsui, Toshiaki

    2014-01-01

    Plastids are specialized cell organelles in plant cells that are differentiated into various forms including chloroplasts, chromoplasts, and amyloplasts, and fulfill important functions in maintaining the overall cell metabolism and sensing environmental factors such as sunlight. It is therefore important to grasp the mechanisms of differentiation and functional changes of plastids in order to enhance the understanding of vegetality. In this chapter, details of a method for the extraction of intact plastids that makes analysis possible while maintaining the plastid functions are provided; in addition, a quantitative shotgun method for analyzing the composition and changes in the content of proteins in plastids as a result of environmental impacts is described.

  4. HAADF-STEM atom counting in atom probe tomography specimens: Towards quantitative correlative microscopy.

    Science.gov (United States)

    Lefebvre, W; Hernandez-Maldonado, D; Moyon, F; Cuvilly, F; Vaudolon, C; Shinde, D; Vurpillot, F

    2015-12-01

    The geometry of atom probe tomography tips strongly differs from standard scanning transmission electron microscopy foils. Whereas the later are rather flat and thin (atom probe tomography specimens. Based on simulations (electron probe propagation and image simulations), the possibility to apply quantitative high angle annular dark field scanning transmission electron microscopy to of atom probe tomography specimens has been tested. The influence of electron probe convergence and the benefice of deconvolution of electron probe point spread function electron have been established. Atom counting in atom probe tomography specimens is for the first time reported in this present work. It is demonstrated that, based on single projections of high angle annular dark field imaging, significant quantitative information can be used as additional input for refining the data obtained by correlative analysis of the specimen in APT, therefore opening new perspectives in the field of atomic scale tomography. Copyright © 2015 Elsevier B.V. All rights reserved.

  5. Quantitative Analysis of Human Salivary Gland-Derived Intact Proteome Using Top-Down Mass Spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Si; Brown, Joseph N.; Tolic, Nikola; Meng, Da; Liu, Xiaowen; Zhang, Haizhen; Zhao, Rui; Moore, Ronald J.; Pevzner, Pavel A.; Smith, Richard D.; Pasa-Tolic, Ljiljana

    2014-05-31

    There are several notable challenges inherent to fully characterizing the entirety of the human saliva proteome using bottom-up approaches, including polymorphic isoforms, post-translational modifications, unique splice variants, deletions, and truncations. To address these challenges, we have developed a top-down based liquid chromatography-mass spectrometry (LC-MS) approach, which cataloged 20 major human salivary proteins with a total of 83 proteoforms, containing a broad range of post-translational modifications. Among these proteins, several previously reported disease biomarker proteins were identified at the intact protein level, such as beta-2 microglobulin (B2M). In addition, intact glycosylated proteoforms of several saliva proteins were also characterized, including intact N-glycosylated protein prolactin inducible protein (PIP) and O-glycosylated acidic protein rich protein (aPRP). These characterized proteoforms constitute an intact saliva proteoform database, which was used for quantitative comparison of intact salivary proteoforms among six healthy individuals. Human parotid (PS) and submandibular/sublingual gland (SMSL) secretion samples (2 μg of protein each) from six healthy individuals were compared using RPLC coupled with the 12T FTICR mass spectrometer. Significantly different protein and PTM patterns were resolved with high reproducibility between PS and SMSL glands. The results from this study provide further insight into the potential mechanisms of PTM pathways in oral glandular secretion, expanding our knowledge of this complex yet easily accessible fluid. Intact protein LC-MS approach presented herein can potentially be applied for rapid and accurate identification of biomarkers from only a few microliters of human glandular saliva.

  6. Radioassays for quantitation of intact complement proteins C2 and B in human serum

    Energy Technology Data Exchange (ETDEWEB)

    Oglesby, T J; Ueda, A; Volanakis, J E

    1988-05-25

    Availability of polyclonal and monoclonal antibodies recognizing determinants on the major cleavage fragments of complement proteins C2 and B enabled development of sensitive radioassays which can be used to quantitate the intact proteins in human sera. Changes in C2 and B concentrations indicative of classical or alternative pathway activation, or both, were seen in normal serum after incubation with complement activators. The authors determined the normal range of C2 concentration to be 11-35 ..mu..g/ml in 32 healthy individuals, and that of protein B to be 74-286 ..mu..g/ml. Sera from patients with systemic lupus erythematosus (SLE), septic shock, infections, and following orthopedic surgery were then assayed. Mean protein B concentration was significantly higher in SLE sera and in the infected and post-operative sera, and the mean C2 concentration in the septic shock group was significantly lower than the mean of healthy individuals. Intact C2 was not detected in known C2-deficient individuals. These assays allow parallel quantitation of the structurally and functionally homologous proteins of the classical (C2) and alternative (B) pathways, which is of interest in patients with genetic and acquired hypocomplementemia. 22 refs.; 3 figs.

  7. Use of a laparoscopic specimen retrieval pouch to facilitate removal of intact or fragmented cystic calculi from standing sedated horses: 8 cases (2012-2015).

    Science.gov (United States)

    Katzman, Scott A; Vaughan, Betsy; Nieto, Jorge E; Galuppo, Larry D

    2016-08-01

    OBJECTIVE To evaluate the use of a laparoscopic specimen retrieval pouch for removal of intact or fragmented cystic calculi from standing horses. DESIGN Retrospective case series. ANIMALS 8 horses (5 geldings and 3 mares) with cystic calculi. PROCEDURES Physical examination and cystoscopic, ultrasonographic, and hematologic evaluations of urinary tract function were performed for each horse. A diagnosis of cystic calculus was made on the basis of results of cystoscopy and ultrasonography. Concurrent urolithiasis or other urinary tract abnormalities identified during preoperative evaluation were recorded. Horses were sedated and placed in standing stocks, and the perineum was aseptically prepared. Direct access to the urinary bladder was gained in geldings via perineal urethrotomy or in mares by a transurethral approach. Calculi were visualized endoscopically, manipulated into the retrieval pouch, and removed intact or fragmented (for larger calculi). RESULTS For 4 geldings and 1 mare, fragmentation was necessary to facilitate calculus removal. Mean duration of surgery was 125 minutes, and trauma to the urinary bladder and urethra was limited to areas of hyperemia and submucosal petechiation. No postoperative complications were encountered for any horse. When lithotripsy was required, the retrieval pouch provided an effective means of stabilizing calculi and containing the fragments for removal. CONCLUSIONS AND CLINICAL RELEVANCE Use of the laparoscopic specimen retrieval pouch was an effective, minimally traumatic method for retrieving cystic calculi from standing horses. The pouch protected the urinary bladder and urethra from trauma during calculus removal and allowed for stabilization, containment, and fragmentation of calculi when necessary.

  8. Epithelium percentage estimation facilitates epithelial quantitative protein measurement in tissue specimens.

    Science.gov (United States)

    Chen, Jing; Toghi Eshghi, Shadi; Bova, George Steven; Li, Qing Kay; Li, Xingde; Zhang, Hui

    2013-12-01

    The rapid advancement of high-throughput tools for quantitative measurement of proteins has demonstrated the potential for the identification of proteins associated with cancer. However, the quantitative results on cancer tissue specimens are usually confounded by tissue heterogeneity, e.g. regions with cancer usually have significantly higher epithelium content yet lower stromal content. It is therefore necessary to develop a tool to facilitate the interpretation of the results of protein measurements in tissue specimens. Epithelial cell adhesion molecule (EpCAM) and cathepsin L (CTSL) are two epithelial proteins whose expressions in normal and tumorous prostate tissues were confirmed by measuring staining intensity with immunohistochemical staining (IHC). The expressions of these proteins were measured by ELISA in protein extracts from OCT embedded frozen prostate tissues. To eliminate the influence of tissue heterogeneity on epithelial protein quantification measured by ELISA, a color-based segmentation method was developed in-house for estimation of epithelium content using H&E histology slides from the same prostate tissues and the estimated epithelium percentage was used to normalize the ELISA results. The epithelium contents of the same slides were also estimated by a pathologist and used to normalize the ELISA results. The computer based results were compared with the pathologist's reading. We found that both EpCAM and CTSL levels, measured by ELISA assays itself, were greatly affected by epithelium content in the tissue specimens. Without adjusting for epithelium percentage, both EpCAM and CTSL levels appeared significantly higher in tumor tissues than normal tissues with a p value less than 0.001. However, after normalization by the epithelium percentage, ELISA measurements of both EpCAM and CTSL were in agreement with IHC staining results, showing a significant increase only in EpCAM with no difference in CTSL expression in cancer tissues. These results

  9. Quantitative cultures of bronchoscopically obtained specimens should be performed for optimal management of ventilator-associated pneumonia.

    Science.gov (United States)

    Baselski, Vickie; Klutts, J Stacey; Baselski, Vickie; Klutts, J Stacey

    2013-03-01

    Ventilator-associated pneumonia (VAP) is a leading cause of health care-associated infection. It has a high rate of attributed mortality, and this mortality is increased in patients who do not receive appropriate empirical antimicrobial therapy. As a result of the overuse of broad-spectrum antimicrobials such as the carbapenems, strains of Acinetobacter, Enterobacteriaceae, and Pseudomonas aeruginosa susceptible only to polymyxins and tigecycline have emerged as important causes of VAP. The need to accurately diagnose VAP so that appropriate discontinuation or de-escalation of antimicrobial therapy can be initiated to reduce this antimicrobial pressure is essential. Practice guidelines for the diagnosis of VAP advocate the use of bronchoalveolar lavage (BAL) fluid obtained either bronchoscopically or by the use of a catheter passed through the endotracheal tube. The CDC recommends that quantitative cultures be performed on these specimens, using ≥ 10(4) CFU/ml to designate a positive culture (http://www.cdc.gov/nhsn/TOC_PSCManual.html, accessed 30 October 2012). However, there is no consensus in the clinical microbiology community as to whether these specimens should be cultured quantitatively, using the aforementioned designated bacterial cell count to designate infection, or by a semiquantitative approach. We have asked Vickie Baselski, University of Tennessee Health Science Center, who was the lead author on one of the seminal papers on quantitative BAL fluid culture, to explain why she believes that quantitative BAL fluid cultures are the optimal strategy for VAP diagnosis. We have Stacey Klutts, University of Iowa, to advocate the semiquantitative approach.

  10. Synchrotron radiation microprobe quantitative analysis method for biomedical specimens

    International Nuclear Information System (INIS)

    Xu Qing; Shao Hanru

    1994-01-01

    Relative changes of trace elemental content in biomedical specimens are obtained easily by means of synchrotron radiation X-ray fluorescence microprobe analysis (SXRFM). However, the accurate assignment of concentration on a g/g basis is difficult. Because it is necessary to know both the trace elemental content and the specimen mass in the irradiated volume simultaneously. the specimen mass is a function of the spatial position and can not be weighed. It is possible to measure the specimen mass indirectly by measuring the intensity of Compton scattered peak for normal XRF analysis using a X-ray tube with Mo anode, if the matrix was consisted of light elements and the specimen was a thin sample. The Compton peak is not presented in fluorescence spectrum for white light SXRFM analysis. The continuous background in the spectrum was resulted from the Compton scattering with a linear polarization X-ray source. Biomedical specimens for SXRFM analysis, for example biological section and human hair, are always a thin sample for high energy X-ray, and they consist of H,C,N and O etc. light elements, which implies a linear relationship between the specimen mass and the Compton scattering background in the high energy region of spectrum. By this way , it is possible to carry out measurement of concentration for SXRFM analysis

  11. Experimental Studies on Permeability of Intact and Singly Jointed Meta-Sedimentary Rocks Under Confining Pressure

    Science.gov (United States)

    Wong, Louis Ngai Yuen; Li, Diyuan; Liu, Gang

    2013-01-01

    Three different types of permeability tests were conducted on 23 intact and singly jointed rock specimens, which were cored from rock blocks collected from a rock cavern under construction in Singapore. The studied rock types belong to inter-bedded meta-sandstone and meta-siltstone with very low porosity and high uniaxial compressive strength. The transient pulse water flow method was employed to measure the permeability of intact meta-sandstone under a confining pressure up to 30 MPa. It showed that the magnitude order of meta-sandstone's intrinsic permeability is about 10-18 m2. The steady-state gas flow method was used to measure the permeability of both intact meta-siltstone and meta-sandstone in a triaxial cell under different confining pressures spanning from 2.5 to 10 MPa. The measured permeability of both rock types ranged from 10-21 to 10-20 m2. The influence of a single natural joint on the permeability of both rock types was studied by using the steady-state water flow method under different confining pressures spanning from 1.25 to 5.0 MPa, including loading and unloading phases. The measured permeability of both jointed rocks ranged from 10-13 to 10-11 m2, where the permeability of jointed meta-siltstone was usually slightly lower than that of jointed meta-sandstone. The permeability of jointed rocks decreases with increasing confining pressure, which can be well fitted by an empirical power law relationship between the permeability and confining pressure or effective pressure. The permeability of partly open cracked specimens is lower than that of open cracked specimens, but it is higher than that of the specimen with a dominant vein for the meta-sandstone under the same confining pressure. The permeability of open cracked rock specimens will partially recover during the unloading confining pressure process. The equivalent crack (joint) aperture is as narrow as a magnitude order of 10-6 m (1 μm) in the rock specimens under confining pressures

  12. On specimen killing in the era of conservation crisis - A quantitative case for modernizing taxonomy and biodiversity inventories.

    Science.gov (United States)

    Waeber, Patrick O; Gardner, Charlie J; Lourenço, Wilson R; Wilmé, Lucienne

    2017-01-01

    For centuries taxonomy has relied on dead animal specimens, a practice that persists today despite the emergence of innovative biodiversity assessment methods. Taxonomists and conservationists are engaged in vigorous discussions over the necessity of killing animals for specimen sampling, but quantitative data on taxonomic trends and specimen sampling over time, which could inform these debates, are lacking. We interrogated a long-term research database documenting 2,723 land vertebrate and 419 invertebrate taxa from Madagascar, and their associated specimens conserved in the major natural history museums. We further compared specimen collection and species description rates for the birds, mammals and scorpions over the last two centuries, to identify trends and links to taxon descriptions. We located 15,364 specimens documenting endemic mammals and 11,666 specimens documenting endemic birds collected between 1820 and 2010. Most specimens were collected at the time of the Mission Zoologique Franco-Anglo-Américaine (MZFAA) in the 1930s and during the last two decades, with major differences according to the groups considered. The small mammal and bat collections date primarily from recent years, and are paralleled by the description of new species. Lemur specimens were collected during the MZFAA but the descriptions of new taxa are recent, with the type series limited to non-killed specimens. Bird specimens, particularly of non-passerines, are mainly from the time of the MZFAA. The passerines have also been intensely collected during the last two decades; the new material has been used to solve the phylogeny of the groups and only two new endemic taxa of passerine birds have been described over the last two decades. Our data show that specimen collection has been critical for advancing our understanding of the taxonomy of Madagascar's biodiversity at the onset of zoological work in Madagascar, but less so in recent decades. It is crucial to look for alternatives to

  13. Value of Tropheryma whipplei quantitative polymerase chain reaction assay for the diagnosis of Whipple disease: usefulness of saliva and stool specimens for first-line screening.

    Science.gov (United States)

    Fenollar, Florence; Laouira, Sonia; Lepidi, Hubert; Rolain, Jean-Marc; Raoult, Didier

    2008-09-01

    Whipple disease (WD) is a chronic infectious disease caused by Tropheryma whipplei. WD DNA has been found in stool and saliva specimens from patients and asymptomatic carriers. A total of 4418 samples that were sent to our center for determination of WD were tested by a T. whipplei-specific quantitative polymerase chain reaction (PCR) based on repetitive sequences. Definite WD was diagnosed in 71 patients, including 55 patients with classic WD (defined by positive results of periodic acid-Schiff staining and/or specific immunohistochemistry of small-bowel biopsy specimens) and 16 patients with localized WD (including patients with endocarditis, neurologic infection, and uveitis). Of the persons without WD, 2.3% had stool specimens positive for T. whipplei by PCR and 0.2% had saliva specimens positive for T. whipplei by PCR. Diagnosis of WD was likely in patients with positive results of both PCR of saliva specimens and PCR of stool specimens (positive predictive value, 95.2%). When the bacterial load was >10(4) colony-forming units per g of stool, the positive predictive value was 100%. A negative result of PCR of a saliva or stool specimen had a negative predictive value of 99.2% for classic WD. For localized WD, positive results of both PCR of saliva specimens and PCR of stool specimens had a sensitivity of 58% (compared with 94% for classic WD). The positive predictive value of testing of blood, cerebrospinal fluid, and urine specimens was 100% for each, and the positive predictive value for testing of duodenal biopsy specimens was 97.5%. T. whipplei-specific quantitative PCR of saliva and stool specimens should be performed as first-line noninvasive screening for WD. When the results for both types of specimens are positive, diagnosis of classic WD should be highly suspected, especially if a high bacterial load is detected. Because PCR of saliva and stool specimens lacks sensitivity for determination of localized WD, invasive samples should be tested on the

  14. Comparison of HER2 and phospho-HER2 expression between biopsy and resected breast cancer specimens using a quantitative assessment method.

    Directory of Open Access Journals (Sweden)

    Yalai Bai

    Full Text Available BACKGROUND: HER2/Neu (ErbB-2 overexpression, which occurs in 15-20% of breast cancer cases, is associated with better response to treatment with the drug trastuzumab. PhosphoHER2 (pHER2 has been evaluated for prediction of response to trastuzumab. Both markers are heterogeneously detected and are potentially subject to loss as a consequence of delayed time to fixation. Here, we quantitatively assess both markers in core needle biopsies (CNBs and matched tumor resections to assess concordance between the core and the resection and between HER2 and pHER2. METHODS: A selected retrospective collection of archival breast cancer cases yielded 67 cases with both core and resection specimens. Both HER2 and pTyr(1248HER2 were analyzed by the AQUA® method of quantitative immunofluorescence on each specimen pair. RESULTS: Both HER2 immunoreactivity (P<0.0001 and pTyr(1248HER2 immunoreactivity (P<0.0001 were lower in resections relative to CNB specimens. However, clinical implications of this change may not be evident since no case changed from 3+ (CNB to negative (resection. Assessment of pTyr(1248HER2 showed no direct correlation with HER2 in either CNB or resection specimens. CONCLUSIONS: The data suggest that measurement of both HER2 and phospho- Tyr(1248HER2, in formalin-fixed tissue by immunological methods is significantly affected by pre-analytic variables. The current study warrants the adequate handling of resected specimens for the reproducible evaluation of HER2 and pHER2. The level of pTyr(1248HER2, was not correlated to total HER2 protein. Further studies are required to determine the significance of these observations with respect to response to HER2 directed therapies.

  15. Wildlife specimen collection, preservation, and shipment

    Science.gov (United States)

    White, C. LeAnn; Dusek, Robert J.; Franson, J. Christian; Friend, Milton; Gibbs, Samantha E.J.; Wild, Margaret A.

    2015-01-01

    Specimens are used to provide supporting information leading to the determination of the cause of disease or death in wildlife and for disease monitoring or surveillance. Commonly used specimens for wildlife disease investigations include intact carcasses, tissues from carcasses, euthanized or moribund animals, parasites, ingested food, feces, or environmental samples. Samples from live animals or the environment (e.g., contaminated feed) in the same vicinity as a mortality event also may be helpful. The type of specimen collected is determined by availability of samples and biological objectives. Multiple fresh, intact carcasses from affected species are the most useful in establishing a cause for a mortality event. Submission of entire carcasses allows observation of gross lesions and abnormalities, as well as disease testing of multiple tissues. Samples from live animals may be more appropriate when sick animals cannot be euthanized (e.g., threatened or endangered species) or for research and monitoring projects examining disease or agents circulating in apparently healthy animals or those not exhibiting clinical signs. Samples from live animals may include collections of blood, hair, feathers, feces, or ectoparasites, or samples obtained by swabbing lesions or orifices. Photographs and videos are useful additions for recording field and clinical signs and conveying conditions at the site. Collection of environmental samples (e.g., feces, water, feed, or soil) may be appropriate when animals cannot be captured for sampling or the disease agent may persist in the environment. If lethal collection is considered necessary, biologists should refer to the policies, procedures, and permit requirements of their institution/facility and the agency responsible for species management (U.S. Fish and Wildlife Service or State natural resource agency) prior to use in the field. If threatened or endangered species are found dead, or there is evidence of illegal take, field

  16. Self-etching adhesive on intact enamel, with and without pre-etching.

    Science.gov (United States)

    Devarasa, G M; Subba Reddy, V V; Chaitra, N L; Swarna, Y M

    2012-05-01

    Bond strengths of composite resin to enamel using self-etch adhesive (SEA) Clearfil SE bond system on intact enamel and enamel pre-etched with phosphoric acid were compared. The objective was to determine if the pre-etching would increase the bond strengths of the SEA systems to intact enamel and to evaluate the effect of pre-etching on bond formation of self-etch adhesives on intact enamel. Labial surfaces of 40 caries free permanent upper central and lateral incisors were cleaned, sectioned of their roots. All specimens were mounted on acrylic block and divided randomly into four groups. In two groups the application of self-etch adhesive, Clearfil SE bond was carried as per manufacturer's instructions, composite cylinders were built, whereas in the other two groups, 37% phosphoric acid etching was done before the application of self-etching adhesives. Then the resin tags were analyzed using scanning electron microscope and shear bond strength was measured using Instron universal testing machine. When phosphoric acid was used, there was significant increase in the depth of penetration of resin tags and in the Shear Bond Strength of composite to enamel. The results indicate that out of both treatment groups, pre-etching the intact enamel with 37% phosphoric acid resulted in formation of longer resin tags and higher depth of penetration of resin tags of the Clearfil SE bond, and attaining higher bond strength of the Clearfil SE bond to intact enamel. Copyright © 2011 Wiley Periodicals, Inc.

  17. Quantitation and Identification of Intact Major Milk Proteins for High-Throughput LC-ESI-Q-TOF MS Analyses.

    Directory of Open Access Journals (Sweden)

    Delphine Vincent

    Full Text Available Cow's milk is an important source of proteins in human nutrition. On average, cow's milk contains 3.5% protein. The most abundant proteins in bovine milk are caseins and some of the whey proteins, namely beta-lactoglobulin, alpha-lactalbumin, and serum albumin. A number of allelic variants and post-translationally modified forms of these proteins have been identified. Their occurrence varies with breed, individuality, stage of lactation, and health and nutritional status of the animal. It is therefore essential to have reliable methods of detection and quantitation of these proteins. Traditionally, major milk proteins are quantified using liquid chromatography (LC and ultra violet detection method. However, as these protein variants co-elute to some degree, another dimension of separation is beneficial to accurately measure their amounts. Mass spectrometry (MS offers such a tool. In this study, we tested several RP-HPLC and MS parameters to optimise the analysis of intact bovine proteins from milk. From our tests, we developed an optimum method that includes a 20-28-40% phase B gradient with 0.02% TFA in both mobile phases, at 0.2 mL/min flow rate, using 75°C for the C8 column temperature, scanning every 3 sec over a 600-3000 m/z window. The optimisations were performed using external standards commercially purchased for which ionisation efficiency, linearity of calibration, LOD, LOQ, sensitivity, selectivity, precision, reproducibility, and mass accuracy were demonstrated. From the MS analysis, we can use extracted ion chromatograms (EICs of specific ion series of known proteins and integrate peaks at defined retention time (RT window for quantitation purposes. This optimum quantitative method was successfully applied to two bulk milk samples from different breeds, Holstein-Friesian and Jersey, to assess differences in protein variant levels.

  18. The effect of coracoacromial ligament excision and acromioplasty on the amount of rotator cuff force production necessary to restore intact glenohumeral biomechanics.

    Science.gov (United States)

    Budoff, Jeffrey E; Lin, Cheng-Li; Hong, Chih-Kai; Chiang, Florence L; Su, Wei-Ren

    2016-06-01

    Coracoacromial ligament (CAL) excision and acromioplasty increase superior and anterosuperior glenohumeral translation. It is unknown how much of an increase in rotator cuff force production is required to re-establish intact glenohumeral biomechanics after these surgical procedures. We hypothesized that, after CAL excision and acromioplasty, an increase in rotator cuff force production would not be necessary to reproduce the anterosuperior and superior translations of the intact specimens. Nine cadaveric shoulders were subjected to loading in the superior and anterosuperior directions in the intact state after CAL excision, acromioplasty, and recording of the translations. The rotator cuff force was then increased to normalize glenohumeral biomechanics. After CAL excision at 150 and 200 N of loading, an increase in the rotator cuff force by 25% decreased anterosuperior translation to the point where there was no significant difference from the intact specimen's translation. After acromioplasty (and CAL excision) at 150 and 200 N, an increase in the rotator cuff force of 25% and 30%, respectively, decreased superior translation to the point where there was no significant difference from the intact specimen's translation. At 150 to 200 N of loading, CAL excision and acromioplasty increase the rotator cuff force required to maintain normal glenohumeral biomechanics by 25% to 30%. After a subacromial decompression, the rotator cuff has an increased force production requirement to maintain baseline glenohumeral mechanics. Under many circumstances, in vivo force requirements may be even greater after surgical attenuation of the coracoacromial arch. Basic Science Study; Biomechanics. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  19. Visualization of plant viral suppressor silencing activity in intact leaf lamina by quantitative fluorescent imaging

    Directory of Open Access Journals (Sweden)

    Francis Kevin P

    2011-08-01

    Full Text Available Abstract Background Transient expression of proteins in plants has become a favoured method over the production of stably transformed plants because, in addition to enabling high protein yields, it is both fast and easy to apply. An enhancement of transient protein expression can be achieved by plant virus-encoded RNA silencing suppressor proteins. Since viral suppressor proteins differ in their efficiency to enhance transient protein expression in plants, we developed a whole-leaf green fluorescent protein (GFP-based imaging assay to quantitatively assess suppressor protein activity. Results In a transient GFP-expression assay using wild-type and GFP-transgenic N. benthamiana, addition of the plant viral suppressors Beet mild yellowing virus (BMYV-IPP P0 or Plum pox virus (PPV HC-Pro was shown to increase fluorescent protein expression 3-4-fold, 7 days post inoculation (dpi when compared to control plants. In contrast, in agroinfiltrated patches without suppressor activity, near complete silencing of the GFP transgene was observed in the transgenic N. benthamiana at 21 dpi. Both co-infiltrated suppressors significantly enhanced GFP expression over time, with HC-Pro co-infiltrations leading to higher short term GFP fluorescence (at 7 dpi and P0 giving higher long term GFP fluorescence (at 21 dpi. Additionally, in contrast to HC-Pro co-infiltrations, an area of complete GFP silencing was observed at the edge of P0 co-infiltrated areas. Conclusions Fluorescence imaging of whole intact leaves proved to be an easy and effective method for spatially and quantitatively observing viral suppressor efficiency in plants. This suppressor assay demonstrates that plant viral suppressors greatly enhanced transient GFP expression, with P0 showing a more prolonged suppressor activity over time than HC-Pro. Both suppressors could prove to be ideal candidates for enhancing target protein expression in plants.

  20. Quantitative measurement of mean inner potential and specimen thickness from high-resolution off-axis electron holograms of ultra-thin layered WSe{sub 2}

    Energy Technology Data Exchange (ETDEWEB)

    Winkler, Florian, E-mail: f.winkler@fz-juelich.de [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Tavabi, Amir H. [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Barthel, Juri [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Gemeinschaftslabor für Elektronenmikroskopie (GFE), RWTH Aachen University, D-52074 Aachen (Germany); Duchamp, Martial [Ernst Ruska-Centre for Microscopy and Spectroscopy with Electrons (ER-C), Forschungszentrum Jülich, D-52425 Jülich (Germany); Peter Grünberg Institute 5 (PGI-5), Forschungszentrum Jülich, D-52425 Jülich (Germany); Yucelen, Emrah [FEI Company, Achtseweg Noord 5, Eindhoven 5600 KA (Netherlands); Borghardt, Sven; Kardynal, Beata E. [Peter Grünberg Institute 9 (PGI-9), Forschungszentrum Jülich, D-52425 Jülich (Germany); and others

    2017-07-15

    The phase and amplitude of the electron wavefunction that has passed through ultra-thin flakes of WSe{sub 2} is measured from high-resolution off-axis electron holograms. Both the experimental measurements and corresponding computer simulations are used to show that, as a result of dynamical diffraction, the spatially averaged phase does not increase linearly with specimen thickness close to an [001] zone axis orientation even when the specimen has a thickness of only a few layers. It is then not possible to infer the local specimen thickness of the WSe{sub 2} from either the phase or the amplitude alone. Instead, we show that the combined analysis of phase and amplitude from experimental measurements and simulations allows an accurate determination of the local specimen thickness. The relationship between phase and projected potential is shown to be approximately linear for extremely thin specimens that are tilted by several degrees in certain directions from the [001] zone axis. A knowledge of the specimen thickness then allows the electrostatic potential to be determined from the measured phase. By using this combined approach, we determine a value for the mean inner potential of WSe{sub 2} of 18.9±0.8 V, which is 12% lower than the value calculated from neutral atom scattering factors. - Highlights: • Quantitative analysis of high resolution electron holograms of WSe{sub 2}. • Local specimen thickness determination and estimation of tilt angle. • Mean inner potential evaluation of WSe2 avoiding dynamical diffraction.

  1. The effect of hepatoprotective preparations thioctacid and flavobion on histones in intact and regenerating lever in irradiated rats

    International Nuclear Information System (INIS)

    Kozhurkova, M.; Kropachova, E.; Mishurova, R.; Reksa, R.

    1992-01-01

    The changes in concentration, total content of histones and relative proportion of individual histone fractions in intact and regenerating liver were followed in rats after administration of hepatoprotective agents flavobion and thioctacid and after whole-body gamma irradiation with a dose 5.7 Gy. Thioctacid alone caused an increase in histone concentration in intact liver whereas flavobion alone did not produce significant quantitative changes. Irradiation alone decreased markedly the concentration and total content of histones in intact as well as regenerating liver of unprotected rats. Administration of thioctacid or flavobion protected from these quantitative histone changes or alleviated them consideradly. In relative proportion of individual histone fractions, the most profound changes were found in H1 histone after flavobion application

  2. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.

    Science.gov (United States)

    Darrow, Brett G; Biskup, Jeffrey J; Weigel, Joseph P; Jones, Michael P; Xie, Xie; Liaw, Peter K; Tharpe, Josh L; Sharma, Aashish; Penumadu, Dayakar

    2017-05-01

    OBJECTIVE To evaluate mechanical properties of pigeon (Columba livia) cadaver intact humeri versus ostectomized humeri stabilized with a locking or nonlocking plate. SAMPLE 30 humeri from pigeon cadavers. PROCEDURES Specimens were allocated into 3 groups and tested in bending and torsion. Results for intact pigeon humeri were compared with results for ostectomized humeri repaired with a titanium 1.6-mm screw locking plate or a stainless steel 1.5-mm dynamic compression plate; the ostectomized humeri mimicked a fracture in a thin cortical bone. Locking plates were secured with locking screws (2 bicortical and 4 monocortical), and nonlocking plates were secured with bicortical nonlocking screws. Constructs were cyclically tested nondestructively in 4-point bending and then tested to failure in bending. A second set of constructs were cyclically tested non-destructively and then to failure in torsion. Stiffness, strength, and strain energy of each construct were compared. RESULTS Intact specimens were stiffer and stronger than the repair groups for all testing methods, except for nonlocking constructs, which were significantly stiffer than intact specimens under cyclic bending. Intact bones had significantly higher strain energies than locking plates in both bending and torsion. Locking and nonlocking plates were of equal strength and strain energy, but not stiffness, in bending and were of equal strength, stiffness, and strain energy in torsion. CONCLUSIONS AND CLINICAL RELEVANCE Results for this study suggested that increased torsional strength may be needed before bone plate repair can be considered as the sole fixation method for avian species.

  3. Comparative Evaluation of Four Real-Time PCR Methods for the Quantitative Detection of Epstein-Barr Virus from Whole Blood Specimens.

    Science.gov (United States)

    Buelow, Daelynn; Sun, Yilun; Tang, Li; Gu, Zhengming; Pounds, Stanley; Hayden, Randall

    2016-07-01

    Monitoring of Epstein-Barr virus (EBV) load in immunocompromised patients has become integral to their care. An increasing number of reagents are available for quantitative detection of EBV; however, there are little published comparative data. Four real-time PCR systems (one using laboratory-developed reagents and three using analyte-specific reagents) were compared with one another for detection of EBV from whole blood. Whole blood specimens seeded with EBV were used to determine quantitative linearity, analytical measurement range, lower limit of detection, and CV for each assay. Retrospective testing of 198 clinical samples was performed in parallel with all methods; results were compared to determine relative quantitative and qualitative performance. All assays showed similar performance. No significant difference was found in limit of detection (3.12-3.49 log10 copies/mL; P = 0.37). A strong qualitative correlation was seen with all assays that used clinical samples (positive detection rates of 89.5%-95.8%). Quantitative correlation of clinical samples across assays was also seen in pairwise regression analysis, with R(2) ranging from 0.83 to 0.95. Normalizing clinical sample results to IU/mL did not alter the quantitative correlation between assays. Quantitative EBV detection by real-time PCR can be performed over a wide linear dynamic range, using three different commercially available reagents and laboratory-developed methods. EBV was detected with comparable sensitivity and quantitative correlation for all assays. Copyright © 2016 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  4. Direct detection of radicals in intact soybean nodules

    DEFF Research Database (Denmark)

    Mathieu, C; Moreau, S; Frendo, P

    1998-01-01

    Electron paramagnetic resonance spectroscopy has been employed to examine the nature of the metal ions and radicals present in intact root nodules of soybean plants grown in the absence of nitrate. The spectra obtained from nodules of different ages using this non-invasive technique show dramatic...... differences, suggesting that there are both qualitative and quantitative changes in the metal ion and radical species present. A major component of the spectra obtained from young nodules is assigned to a complex (Lb-NO) of nitric oxide (NO.) with the heme protein leghemoglobin (Lb). This Lb-NO species, which...... has not been previously detected in intact root nodules of plants grown in the absence of nitrate, is thought to be formed by reaction of nitric oxide with iron(II) leghemoglobin. The nitric oxide may be generated from arginine via a nitric oxide synthase-like activity present in the nodules...

  5. Quantitative polarized Raman spectroscopy in highly turbid bone tissue.

    Science.gov (United States)

    Raghavan, Mekhala; Sahar, Nadder D; Wilson, Robert H; Mycek, Mary-Ann; Pleshko, Nancy; Kohn, David H; Morris, Michael D

    2010-01-01

    Polarized Raman spectroscopy allows measurement of molecular orientation and composition and is widely used in the study of polymer systems. Here, we extend the technique to the extraction of quantitative orientation information from bone tissue, which is optically thick and highly turbid. We discuss multiple scattering effects in tissue and show that repeated measurements using a series of objectives of differing numerical apertures can be employed to assess the contributions of sample turbidity and depth of field on polarized Raman measurements. A high numerical aperture objective minimizes the systematic errors introduced by multiple scattering. We test and validate the use of polarized Raman spectroscopy using wild-type and genetically modified (oim/oim model of osteogenesis imperfecta) murine bones. Mineral orientation distribution functions show that mineral crystallites are not as well aligned (pbones (28+/-3 deg) compared to wild-type bones (22+/-3 deg), in agreement with small-angle X-ray scattering results. In wild-type mice, backbone carbonyl orientation is 76+/-2 deg and in oim/oim mice, it is 72+/-4 deg (p>0.05). We provide evidence that simultaneous quantitative measurements of mineral and collagen orientations on intact bone specimens are possible using polarized Raman spectroscopy.

  6. Quantitative analysis of the difference between an intact complete discoid lateral meniscus and a torn complete discoid meniscus on MR imaging: a feasibility study for a new classification

    International Nuclear Information System (INIS)

    Lee, Mi Hee; Choi, Sang-Hee; Woo, Sook Young

    2010-01-01

    To determine the quantitative difference between an intact complete discoid lateral meniscus (CDLM) and a torn CDLM on MR imaging. Between May 2005 to November 2009, 137 patients with a CDLM (107 intact CDLM and 30 torn CDLM) and 92 patients with a normal meniscus were included in this study. The evaluated parameters were the height of the posterior horn of the lateral and medial menisci on the sagittal images and their ratio as assessed by two observers twice at an interval of 1 month. Each parameter was analyzed based on the Kruskal Wallis test, and the analysis using the mixed model. Intraclass correlation coefficient (ICC) was used to determine the interobserver reliabilities at session 2. The mean heights of the posterior horn of the lateral and medial menisci on the sagittal images for an intact CDLM, a torn CLDM, and a normal meniscus were 6.5, 7.3, 5.7 and 6.6, 6.4, 6.7 mm at session 1, respectively. The mean heights of the posterior horn of the lateral and medial menisci on the sagittal images for an intact CDLM, a torn CDLM, and a normal meniscus for both observers were 6.5, 7.2, 5.7 and 6.6, 6.3, 6.8 mm at session 2, respectively. The ratio of the height of the lateral to the height of the medial meniscus for an intact CDLM at both sessions for both observers was 1.0. The ratios were 1.2 and 0.8 for a torn CDLM and for a normal meniscus, respectively, at both sessions for observer 1. The ratios were 1.2 and 0.9 for a torn CDLM and for a normal meniscus, respectively, at session 2 for observer 2. The heights of the posterior horn of the lateral meniscus on the sagittal images and the ratios of the heights of the lateral to the medial menisci in all three groups were statistically significantly different for both sessions (p < 0.0001). The interobserver ICCs for each parameter of both an intact CDLM and a torn CDLM at session 2 showed high correlations (p < 0.0001). The height of the lateral meniscus and the ratio of the height of the lateral to the height

  7. Elemental microanalysis of biological and medical specimens with a scanning proton microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; Mazzolini, A.P.

    1979-01-01

    The scanning proton microprobe is shown to be a sensitive instrument for elemental microanalysis of cells and tissues in biological and medical specimens. The preparation of specimens and their behaviour under irradiation are crucial and the application of quantitative scanning analysis to the monitoring of such problems is illustrated

  8. Comparison of Intact PTH and Bio-Intact PTH Assays Among Non-Dialysis Dependent Chronic Kidney Disease Patients.

    Science.gov (United States)

    Einbinder, Yael; Benchetrit, Sydney; Golan, Eliezer; Zitman-Gal, Tali

    2017-09-01

    The third-generation bio-intact parathyroid hormone (PTH) (1-84) assay was designed to overcome problems associated with the detection of C-terminal fragments by the second-generation intact PTH assay. The two assays have been compared primarily among dialysis populations. The present study evaluated the correlations and differences between these two PTH assays among patients with chronic kidney disease (CKD) stages 3 to 5 not yet on dialysis. Blood samples were collected from 98 patients with CKD stages 3 to 5. PTH concentrations were measured simultaneously by using the second-generation - PTH intact-STAT and third-generation bio-intact 1-84 PTH assays. Other serum biomarkers of bone mineral disorders were also assessed. CKD stage was calculated by using the CKD-Epidemiology Collaboration (EPI) formula. Serum bio-intact PTH concentrations were strongly correlated but significantly lower than the intact PTH concentrations (r=0.963, Pbio-intact PTH) positively correlated with urea (r=0.523, r=0.504; P=0.002, respectively), phosphorus (r=0.532, r=0.521; Pbio-intact PTH assay detected significantly lower PTH concentrations compared with intact PTH assay. Additional studies that correlate the diagnosis and management of CKD mineral and bone disorders with bone histomorphometric findings are needed to determine whether bio-intact PTH assay results are better surrogate markers in these early stages of CKD. © The Korean Society for Laboratory Medicine

  9. Modeling rock specimens through 3D printing: Tentative experiments and prospects

    Science.gov (United States)

    Jiang, Quan; Feng, Xiating; Song, Lvbo; Gong, Yahua; Zheng, Hong; Cui, Jie

    2016-02-01

    Current developments in 3D printing (3DP) technology provide the opportunity to produce rock-like specimens and geotechnical models through additive manufacturing, that is, from a file viewed with a computer to a real object. This study investigated the serviceability of 3DP products as substitutes for rock specimens and rock-type materials in experimental analysis of deformation and failure in the laboratory. These experiments were performed on two types of materials as follows: (1) compressive experiments on printed sand-powder specimens in different shapes and structures, including intact cylinders, cylinders with small holes, and cuboids with pre-existing cracks, and (2) compressive and shearing experiments on printed polylactic acid cylinders and molded shearing blocks. These tentative tests for 3DP technology have exposed its advantages in producing complicated specimens with special external forms and internal structures, the mechanical similarity of its product to rock-type material in terms of deformation and failure, and its precision in mapping shapes from the original body to the trial sample (such as a natural rock joint). These experiments and analyses also successfully demonstrate the potential and prospects of 3DP technology to assist in the deformation and failure analysis of rock-type materials, as well as in the simulation of similar material modeling experiments.

  10. Microleakage of stainless steel crowns placed on intact and extensively destroyed primary first molars: an in vitro study.

    Science.gov (United States)

    Seraj, Bahman; Shahrabi, Mahdi; Motahari, Pouria; Ahmadi, Rahil; Ghadimi, Sara; Mosharafian, Shahram; Mohammadi, Kaveh; Javad Kharazifard, Mohammad

    2011-01-01

    The purpose of this investigation was to evaluate the effect of residual tooth structure on the microleakage of stainless steel crowns cemented with glass ionomer on primary maxillary and mandibular first molars. Thirty extracted primary molars were divided into 2 groups: group 1 included intact teeth; and group 2 included extensively carious samples. Each tooth received standard preparation, and each crown was luted with G-CEM on its specific specimen. Teeth were loaded vertically and transferred to distilled water. After thermocycling and immersing in methylene blue solution, the teeth were sectioned and examined microscopically for microleakage. Data were analyzed using Mann-Whitney U and Wilcoxon signed-rank tests. All specimens (intact and damaged teeth) had microleakage, although most of these presented only minimum microleakage. No statistically significant differences were found in the microleakage of sound and extensively carious teeth on either the buccal (P=.62) or lingual (P=.65) side. Buccal (P=.73) and lingual (P=.63) surfaces showed similar microleakage scores in primary maxillary and mandibular molars. There was no significant difference in the microleakage of sound or extensively carious teeth and primary maxillary or mandibular first molars.

  11. A comparative kinetic RT/-PCR strategy for the quantitation of mRNAs in microdissected human renal biopsy specimens.

    Science.gov (United States)

    Del Prete, D; Forino, M; Gambaro, G; D'Angelo, A; Baggio, B; Anglani, F

    1998-01-01

    Molecular biology techniques, to be applicable to a diagnostic renal biopsy specimen, should (1) be highly sensitive to be performed on a very small quantity of tissue; (2) be quantitative because they have to analyze genes normally expressed in the tissue and (3) allow the analysis of as large a number of genes as possible. Among different methods, only the reverse-transcriptase polymerase chain reaction (RT/-PCR) might comply with previous requisites, but the few RT/-PCR examples on renal biopsies in the literature do not allow starting RNA quantification and quality control; furthermore they have the drawback of analyzing only few genes. In an ongoing study to assess the expression of a number of genes in glomeruli and in tubulointerstitium of patients with different nephropathies, we developed a comparative RT/-PCR kinetic strategy based on the purification and quantification of total glomerular and tubulointerstitial RNA and on the use of an internal standard, the housekeeping gene G3PDH. We demonstrate that in microdissected diagnostic renal biopsies (1) glomerular and interstitial starting RNA can be quantified; (2) the G3PDH gene may be used both as an internal standard and as an indirect marker of RNA integrity; (3) as low as 28 ng of total RNA is sufficient to obtain PCR products of eight genes, and (4) it is worth to operate on microdissected biopsy specimens because of the different expression of genes in the two renal compartments.

  12. The PAXgene(® tissue system preserves phosphoproteins in human tissue specimens and enables comprehensive protein biomarker research.

    Directory of Open Access Journals (Sweden)

    Sibylle Gündisch

    Full Text Available Precise quantitation of protein biomarkers in clinical tissue specimens is a prerequisite for accurate and effective diagnosis, prognosis, and personalized medicine. Although progress is being made, protein analysis from formalin-fixed and paraffin-embedded tissues is still challenging. In previous reports, we showed that the novel formalin-free tissue preservation technology, the PAXgene Tissue System, allows the extraction of intact and immunoreactive proteins from PAXgene-fixed and paraffin-embedded (PFPE tissues. In the current study, we focused on the analysis of phosphoproteins and the applicability of two-dimensional gel electrophoresis (2D-PAGE and enzyme-linked immunosorbent assay (ELISA to the analysis of a variety of malignant and non-malignant human tissues. Using western blot analysis, we found that phosphoproteins are quantitatively preserved in PFPE tissues, and signal intensities are comparable to that in paired, frozen tissues. Furthermore, proteins extracted from PFPE samples are suitable for 2D-PAGE and can be quantified by ELISA specific for denatured proteins. In summary, the PAXgene Tissue System reliably preserves phosphoproteins in human tissue samples, even after prolonged fixation or stabilization times, and is compatible with methods for protein analysis such as 2D-PAGE and ELISA. We conclude that the PAXgene Tissue System has the potential to serve as a versatile tissue fixative for modern pathology.

  13. Quantitative sensing of corroded steel rebar embedded in cement mortar specimens using ultrasonic testing

    Science.gov (United States)

    Owusu Twumasi, Jones; Le, Viet; Tang, Qixiang; Yu, Tzuyang

    2016-04-01

    Corrosion of steel reinforcing bars (rebars) is the primary cause for the deterioration of reinforced concrete structures. Traditional corrosion monitoring methods such as half-cell potential and linear polarization resistance can only detect the presence of corrosion but cannot quantify it. This study presents an experimental investigation of quantifying degree of corrosion of steel rebar inside cement mortar specimens using ultrasonic testing (UT). A UT device with two 54 kHz transducers was used to measure ultrasonic pulse velocity (UPV) of cement mortar, uncorroded and corroded reinforced cement mortar specimens, utilizing the direct transmission method. The results obtained from the study show that UPV decreases linearly with increase in degree of corrosion and corrosion-induced cracks (surface cracks). With respect to quantifying the degree of corrosion, a model was developed by simultaneously fitting UPV and surface crack width measurements to a two-parameter linear model. The proposed model can be used for predicting the degree of corrosion of steel rebar embedded in cement mortar under similar conditions used in this study up to 3.03%. Furthermore, the modeling approach can be applied to corroded reinforced concrete specimens with additional modification. The findings from this study show that UT has the potential of quantifying the degree of corrosion inside reinforced cement mortar specimens.

  14. Bulk specimen X-ray microanalysis of freeze-fractured, freeze-dried tissues in gerontological research

    International Nuclear Information System (INIS)

    Nagy, I.

    1988-01-01

    The rationale for choosing the freeze-fracture freeze-drying (FFFD) method of biological bulk specimen preparation as well as the theoretical and practical problems of this method are treated. FFFD specimens are suitable for quantitative X-ray microanalysis of biologically relevant elements. Although the spatial resolution of this analytical technique is low, the application of properly selected bulk standard crystals as well as the measurement of the intracellular water and dry mass content by means of another method developed in the same laboratory, allow us to obtain useful information about the age-dependent changes of ionic composition in the main intracellular compartments. The paper summarizes the problems with regard to specimen preparation, beam penetration and the quantitative analysis of FFFD specimens. The method has been applied so far mainly for the analysis of intranuclear and intracytoplasmic concentrations of Na, C1 and K in various types of cells and has resulted in a significant contribution to our understanding of the cellular mechanisms of aging. 84 references

  15. Cracking and Failure in Rock Specimen Containing Combined Flaw and Hole under Uniaxial Compression

    Directory of Open Access Journals (Sweden)

    Xiang Fan

    2018-01-01

    Full Text Available Flaw is a key factor influencing failure behavior of a fractured specimen. In the present study, rectangular-flawed specimens were prepared using sandstone to investigate the effect of flaw on failure behavior of rock. Open flaw and cylindrical hole were simultaneously precut within rock specimens using high-pressure water jet cutting technology. Five series of specimens including intact, single-hole-alone, two-hole-alone, single-hole and two-flaw, and two-hole and single-flaw blocks were prepared. Uniaxial compressive tests using a rigid servo control instrument were carried out to investigate the fracture processes of these flawed specimens. It is observed that during loading, internal stress always intensively distributed at both sidewalls of open hole, especially at midpoint of sidewalls, so rock crumb flaking was firstly observed among all sandstone specimens containing single hole or two holes. Cracking around open hole is associated with the flaw inclination angle which was observed in Series III and V. Crack easily initiated at the tips of flaw with inclination angles of 0°, 30°, and 60° but hard for 90° in Series III and V. Rock burst was the major failure mode among most tested specimens, which generally induced new cracks and finally created crater shape. Additionally, due to extrusion between blocks, new shear or tensile cracks were generated and the rock specimen surface spalled. Eventually, four typical failure processes including rock crumb flaking, crack initiation and propagation, rock burst, and second rupture, were summarized.

  16. Optimal design and fabrication of three-dimensional calibration specimens for scanning probe microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Liu Xiaoning; Luo Tingting; Chen Yuhang; Huang Wenhao [Department of Precision Machinery and Instrumentation, University of Science and Technology of China, 230026 Hefei (China); Piaszenski, Guido [Raith GmbH, Konrad-Adenauer-Allee 8, 44263 Dortmund (Germany)

    2012-05-15

    Micro-/nano-scale roughness specimens are highly demanded to synthetically calibrate the scanning probe microscopy (SPM) instrument. In this study, three-dimensional (3D) specimens with controllable main surface evaluation parameters were designed. In order to improve the design accuracy, the genetic algorithm was introduced into the conventional digital filter method. A primary 3D calibration specimen with the dimension of 10 {mu}m x 10 {mu}m was fabricated by electron beam lithography. Atomic force microscopy characterizations demonstrated that the statistical and spectral parameters of the fabricated specimen match well with the designed values. Such a kind of 3D specimens has the potential to calibrate the SPM for applications in quantitative surface evaluations.

  17. Positive Youth Development, Life Satisfaction and Problem Behaviors of Adolescents in Intact and Non-Intact Families in Hong Kong

    Directory of Open Access Journals (Sweden)

    Daniel Tan Lei Shek

    2013-08-01

    Full Text Available This study investigated whether Chinese adolescents living in intact and non-intact families differed in their positive development, life satisfaction, and risk behavior. A total of 3,328 Secondary 1 students responded to measures of positive youth development (such as resilience and psychosocial competencies, life satisfaction, and risk behavior (substance abuse, delinquency, Internet addiction, consumption of pornographic materials, self-harm, and behavioral intention to engage in problem behavior. Findings revealed that adolescents growing up in intact families reported higher levels of positive developmental outcomes and life satisfaction as compared with adolescents from non-intact families. Adolescents in non-intact families also reported higher levels of risk behaviors than those growing up in intact families.

  18. The uptake of radioactive iodine in rat intact Graafian follicles

    International Nuclear Information System (INIS)

    Lieberman, L.M.; Lieberman, G.L.; Lieberman, M.E.

    1984-01-01

    The concentration of iodine-131 in the ovaries of mammals has important implications in the use of I-131 for the diagnosis and treatment of thyroid disease in women. The authors studied the I-131 uptake in whole ovaries and in isolated Graafian follicles of sexually mature rats. Adult female Sprague-Dawley rats, in groups of 5-6 animals, were injected IP with 10-50 μCi of I-131, at 3, 12, and 24 hrs prior to the day of proestrus and killed on the day of proestrus. The thyroid gland and ovaries were removed intact and these organs, as well as eight other tissue specimens, were weighed. The large preovulatory follicles (6-9/ovary) were then isolated under a dissecting microscope and the remaining ovary weighed. All samples were counted in a gamma well counter and the % dose/g estimated. The thyroid gland showed 23.7% dose/organ at 24 hrs. Blood decreased from 1.6% dose/g at 3 hrs to 0.5% dose/g at 24 hrs with the uterus showing 1.1% dose/g and 0.4% dose/g at the same times. Ovarian tissue was 0.5, 0.1, and 0.1% dose/g at 3,12, and 24 hrs respectively, while the intact Graafian follicles had from one-tenth to one-third the concentration of the ovary at the same times. (0.05, 0.03, and 0.03% dose/g). The authors found that the intact Graafian follicle concentrates approximately one-thirtieth to one-sixteenth of the I-131 in the blood and one-tenth to one-third of the I-131 in the ovary. This suggests that there is no active uptake of I-131 in the follicle or follicular fluid

  19. Exploratory investigations of hypervelocity intact capture spectroscopy

    Science.gov (United States)

    Tsou, P.; Griffiths, D. J.

    1993-01-01

    The ability to capture hypervelocity projectiles intact opens a new technique available for hypervelocity research. A determination of the reactions taking place between the projectile and the capture medium during the process of intact capture is extremely important to an understanding of the intact capture phenomenon, to improving the capture technique, and to developing a theory describing the phenomenon. The intact capture of hypervelocity projectiles by underdense media generates spectra, characteristic of the material species of projectile and capture medium involved. Initial exploratory results into real-time characterization of hypervelocity intact capture techniques by spectroscopy include ultra-violet and visible spectra obtained by use of reflecting gratings, transmitting gratings, and prisms, and recorded by photographic and electronic means. Spectrometry proved to be a valuable real-time diagnostic tool for hypervelocity intact capture events, offering understanding of the interactions of the projectile and the capture medium during the initial period and providing information not obtainable by other characterizations. Preliminary results and analyses of spectra produced by the intact capture of hypervelocity aluminum spheres in polyethylene (PE), polystyrene (PS), and polyurethane (PU) foams are presented. Included are tentative emission species identifications, as well as gray body temperatures produced in the intact capture process.

  20. The usefulness of 3D quantitative analysis with using MRI for measuring osteonecrosis of the femoral head

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Lee, Sun Wha; Park, Youn Soo

    2006-01-01

    We wanted to evaluate the usefulness of MRI 3D quantitative analysis for measuring osteonecrosis of the femoral head in comparison with MRI 2D quantitative analysis and quantitative analysis of the specimen. For 3 months at our hospital, 14 femoral head specimens with osteonecrosis were obtained after total hip arthroplasty. The patients preoperative MRIs were retrospectively reviewed for quantitative analysis of the size of the necrosis. Each necrotic fraction of the femoral head was measured by 2D quantitative analysis with using mid-coronal and mid-sagittal MRIs, and by 3D quantitative analysis with using serial continuous coronal MRIs and 3D reconstruction software. The necrotic fraction of the specimen was physically measured by the fluid displacement method. The necrotic fraction according to MRI 2D or 3D quantitative analysis was compared with that of the specimen by using Spearman's correlation test. On the correlative analysis, the necrotic fraction by MRI 2D quantitative analysis and quantitative analysis of the specimen showed moderate correlation (r = 0.657); on the other hand, the necrotic fraction by MRI 3D quantitative analysis and quantitative analysis of the specimen demonstrated a strong correlation (r = 0.952) (ρ < 0.05). MRI 3D quantitative analysis was more accurate than 2D quantitative analysis using MRI for measuring osteonecrosis of the femoral head. Therefore, it may be useful for predicting the clinical outcome and deciding the proper treatment option

  1. On the quantitativeness of EDS STEM

    Energy Technology Data Exchange (ETDEWEB)

    Lugg, N.R. [Institute of Engineering Innovation, The University of Tokyo, 2-11-16, Yayoi, Bunkyo-ku, Tokyo 113-8656 (Japan); Kothleitner, G. [Institute for Electron Microscopy and Nanoanalysis, Graz University of Technology, Steyrergasse 17, 8010 Graz (Austria); Centre for Electron Microscopy, Steyrergasse 17, 8010 Graz (Austria); Shibata, N.; Ikuhara, Y. [Institute of Engineering Innovation, The University of Tokyo, 2-11-16, Yayoi, Bunkyo-ku, Tokyo 113-8656 (Japan)

    2015-04-15

    Chemical mapping using energy dispersive X-ray spectroscopy (EDS) in scanning transmission electron microscopy (STEM) has recently shown to be a powerful technique in analyzing the elemental identity and location of atomic columns in materials at atomic resolution. However, most applications of EDS STEM have been used only to qualitatively map whether elements are present at specific sites. Obtaining calibrated EDS STEM maps so that they are on an absolute scale is a difficult task and even if one achieves this, extracting quantitative information about the specimen – such as the number or density of atoms under the probe – adds yet another layer of complexity to the analysis due to the multiple elastic and inelastic scattering of the electron probe. Quantitative information may be obtained by comparing calibrated EDS STEM with theoretical simulations, but in this case a model of the structure must be assumed a priori. Here we first theoretically explore how exactly elastic and thermal scattering of the probe confounds the quantitative information one is able to extract about the specimen from an EDS STEM map. We then show using simulation how tilting the specimen (or incident probe) can reduce the effects of scattering and how it can provide quantitative information about the specimen. We then discuss drawbacks of this method – such as the loss of atomic resolution along the tilt direction – but follow this with a possible remedy: precession averaged EDS STEM mapping. - Highlights: • Signal obtained in EDS STEM maps (of STO) compared to non-channelling signal. • Deviation from non-channelling signal occurs in on-axis experiments. • Tilting specimen: signal close to non-channelling case but atomic resolution is lost. • Tilt-precession series: non-channelling signal and atomic-resolution features obtained. • Associated issues are discussed.

  2. Intact glycopeptide characterization using mass spectrometry.

    Science.gov (United States)

    Cao, Li; Qu, Yi; Zhang, Zhaorui; Wang, Zhe; Prytkova, Iya; Wu, Si

    2016-05-01

    Glycosylation is one of the most prominent and extensively studied protein post-translational modifications. However, traditional proteomic studies at the peptide level (bottom-up) rarely characterize intact glycopeptides (glycosylated peptides without removing glycans), so no glycoprotein heterogeneity information is retained. Intact glycopeptide characterization, on the other hand, provides opportunities to simultaneously elucidate the glycan structure and the glycosylation site needed to reveal the actual biological function of protein glycosylation. Recently, significant improvements have been made in the characterization of intact glycopeptides, ranging from enrichment and separation, mass spectroscopy (MS) detection, to bioinformatics analysis. In this review, we recapitulated currently available intact glycopeptide characterization methods with respect to their advantages and limitations as well as their potential applications.

  3. Bone biopsy needles. Mechanical properties, needle design and specimen quality

    International Nuclear Information System (INIS)

    Keulers, Annika; Penzkofer, T.; Cunha-Cruz, V.C.; Bruners, P.; Helmholtz Inst. fuer biomedizinische Technik, Aachen; Braunschweig, T.; Schmitz-Rode, T.; Mahnken, A.; Helmholtz Inst. fuer biomedizinische Technik, Aachen

    2011-01-01

    To quantitatively analyze differences in mechanical properties, needle design including signs of wear, subjective handling and specimen quality of bone biopsy needles. Materials and Methods: In this study 19 different bone biopsy systems (total 38; 2 /type) were examined. With each biopsy needle five consecutive samples were obtained from vertebral bodies of swine. During puncture a force-torques sensor measured the mechanical properties and subjective handling was assessed. Before and after each biopsy the needles were investigated using a profile projector and signs of wear were recorded. Afterwards, a pathologist semi-quantitatively examined the specimen regarding sample quality. The overall evaluation considered mechanical properties, needle wear, subjective handling and sample quality. Differences were assessed for statistical significance using ANOVA and t-test. Results: Needle diameter (p = 0.003) as well as needle design (p = 0.008) affect the mechanical properties significantly. Franseen design is significantly superior to other needle designs. Besides, length reduction recorded by the profile projector, as a quality criterion showed notable distinctions in between the needle designs. Conclusion: Bone biopsy needles vary significantly in performance. Needle design has an important influence on mechanical properties, handling and specimen quality. Detailed knowledge of those parameters would improve selecting the appropriate bone biopsy needle. (orig.)

  4. Quantitative EDXS: Influence of geometry on a four detector system

    International Nuclear Information System (INIS)

    Kraxner, Johanna; Schäfer, Margit; Röschel, Otto; Kothleitner, Gerald; Haberfehlner, Georg; Paller, Manuel; Grogger, Werner

    2017-01-01

    The influence of the geometry on quantitative energy dispersive X-ray spectrometry (EDXS) analysis is determined for a ChemiSTEM system (Super-X) in combination with a low-background double-tilt specimen holder. For the first time a combination of experimental measurements with simulations is used to determine the positions of the individual detectors of a Super-X system. These positions allow us to calculate the detector's solid angles and estimate the amount of detector shadowing and its influence on quantitative EDXS analysis, including absorption correction using the ζ-factor method. Both shadowing by the brass portions and the beryllium specimen carrier of the holder severely affect the quantification of low to medium atomic number elements. A multi-detector system is discussed in terms of practical consequences of the described effects, and a quantitative evaluation of a Fayalit sample is demonstrated. Corrections and suggestions for minimizing systematic errors are discussed to improve quantitative methods for a multi-detector system. - Highlights: • Geometrical issues for EDXS quantification on a Super-X system. • Realistic model of a specimen holder using X-ray computed tomography. • Determination of the exact detector positions of a Super-X system. • Influence of detector shadowing and Be specimen carrier on quantitative EDXS.

  5. Determination of the carbon isotopic composition of whole/intact biological specimens using at-line direct thermal desorption to effect thermally assisted hydrolysis/methylation

    NARCIS (Netherlands)

    Akoto, L.; Vreuls, R.J.J.; Irth, H.; Floris, V.; Hoogveld, H.L.; Pel, R.

    2008-01-01

    In this paper, we discuss the use of a direct thermal desorption (DTD) interface as an alternative to Curie-point flash pyrolysis system as an inlet technique in gas chromatography–combustion isotope-ratio mass spectrometry (GC/C-IRMS) analysis of whole/intact phytoplankton and zooplankton

  6. A quantitative swab is a good non-invasive alternative to a quantitative biopsy for quantifying bacterial load in wounds healing by second intention in horses.

    Science.gov (United States)

    Van Hecke, L L; Hermans, K; Haspeslagh, M; Chiers, K; Pint, E; Boyen, F; Martens, A M

    2017-07-01

    The aim of this study was to evaluate different techniques for diagnosing wound infection in wounds healing by second intention in horses and to assess the effect of a vortex and sonication protocol on quantitative bacteriology in specimens with a histologically confirmed biofilm. In 50 wounds healing by second intention, a clinical assessment, a quantitative swab, a semi-quantitative swab, and a swab for cytology were compared to a quantitative tissue biopsy (reference standard). Part of the biopsy specimen was examined histologically for evidence of a biofilm. There was a significant, high correlation (Pquantitative swabs and the quantitative biopsies. The semi-quantitative swabs showed a significant, moderate correlation with the quantitative biopsies (Pquantitative swab is an acceptable non-invasive alternative to a quantitative biopsy for quantifying bacterial load in equine wounds healing by second intention. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Serum steroid levels in intact and endocrine ablated BALB/c nude mice and their intact littermates

    DEFF Research Database (Denmark)

    Brünner, N; Svenstrup, B; Spang-Thomsen, M

    1986-01-01

    An investigation was made of the serum steroid levels found in intact and endocrine ablated nude mice of both sexes and in their intact homozygous littermates. The results showed that nude mice have a normal steroidogenesis, but with decreased levels of circulating steroids compared to those...

  8. Standard practice for preparation and use of direct tension stress-corrosion test specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1985-01-01

    1.1 This practice covers procedures for designing, preparing, and using ASTM standard tension test specimens for investigating susceptibility to stress-corrosion cracking. Axially loaded specimens may be stressed quantitatively with equipment for application of either a constant load, constant strain, or with a continuously increasing strain. 1.2 Tension test specimens are adaptable for testing a wide variety of product forms as well as parts joined by welding, riveting, or various other methods. 1.3 The exposure of specimens in a corrosive environment is treated only briefly because other standards are being prepared to deal with this aspect. Meanwhile, the investigator is referred to Practices G35, G36, G37, and G44, and to ASTM Special Technical Publication 425 (1).

  9. Effect of stifle angle on the magnitude of the tibial plateau angle measurement in dogs with intact and transected cranial cruciate ligament. A cadaveric study.

    Science.gov (United States)

    Aulakh, K S; Harper, T A M; Lanz, O I; Daniel, G B; Werre, S R

    2011-01-01

    To determine the effect of stifle angle on the magnitude of the radiographic tibial plateau angle (TPA) in normal and cranial cruciate ligament (CCL) -deficient stifles. Three pairs of canine cadaver hindlimbs from three skeletally mature dogs were positioned in a custom-made positioning device. A lateral radiograph of each specimen was obtained before and after transection of the CCL at four stifle angles (90°, 110°, 135° and 140-150° [i.e. maximum extension]), based on goniometric measurements. Four observers determined the radiographic TPA twice for each radiograph with a minimum of two days between each measurement. The radiographic TPA measurements in all specimens at different stifle angles with intact CCL and transected CCL were compared with mixed-model ANOVA. The effect of stifle angle, CCL transection, and interaction between the two on observer TPA measurement variability was also determined using the coefficient of variation. Tibial plateau angle was not statistically different in the stifle angles for either the intact or transected CCL. There was also no statistical difference for TPA between intact and transected CCL groups at each of the stifle angles. Stifle angle, CCL transection and interaction between the two did not have any significant effect for intra-observer and inter-observer variation. The angle of the stifle during radiography does not influence the magnitude of the TPA measurement as determined on true lateral radiographs of the stifle and tibia in cadaveric canine limbs.

  10. Preliminary investigation of candidate specimens for the Egyptian environmental specimen bank

    International Nuclear Information System (INIS)

    Shawky, S.; Amer, H.; Schladot, J.D.; Ostapczuk, P.; Emons, H.; Abou El-Nour, F.

    2000-01-01

    In the frame of establishing an environmental monitoring program related to environmental specimen banking in egypt, some candidate specimens from the aquatic environment (Fish muscle, fish liver; mussels) were investigated. The selection of specimens and sampling sites is described. Specimens are chemically characterised with respect to some major and trace elements and the results are compared with data obtained from comparable specimens collected in aquatic ecosystems of germany

  11. Clean Transfer of Large Graphene Single Crystals for High-Intactness Suspended Membranes and Liquid Cells.

    Science.gov (United States)

    Zhang, Jincan; Lin, Li; Sun, Luzhao; Huang, Yucheng; Koh, Ai Leen; Dang, Wenhui; Yin, Jianbo; Wang, Mingzhan; Tan, Congwei; Li, Tianran; Tan, Zhenjun; Liu, Zhongfan; Peng, Hailin

    2017-07-01

    The atomically thin 2D nature of suspended graphene membranes holds promising in numerous technological applications. In particular, the outstanding transparency to electron beam endows graphene membranes great potential as a candidate for specimen support of transmission electron microscopy (TEM). However, major hurdles remain to be addressed to acquire an ultraclean, high-intactness, and defect-free suspended graphene membrane. Here, a polymer-free clean transfer of sub-centimeter-sized graphene single crystals onto TEM grids to fabricate large-area and high-quality suspended graphene membranes has been achieved. Through the control of interfacial force during the transfer, the intactness of large-area graphene membranes can be as high as 95%, prominently larger than reported values in previous works. Graphene liquid cells are readily prepared by π-π stacking two clean single-crystal graphene TEM grids, in which atomic-scale resolution imaging and temporal evolution of colloid Au nanoparticles are recorded. This facile and scalable production of clean and high-quality suspended graphene membrane is promising toward their wide applications for electron and optical microscopy. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. [Impact of specimen collection and storage consumable products on trace element quantitative analysis].

    Science.gov (United States)

    Song, Yan-shuang; Gu, Yong-en; Ba, Te; Zhai, Min; Pu, Ji; Shen, Zhen-lin; Tang, Shi-chuan; Jia, Guang

    2012-07-01

    This study aimed to explore the impact of specimen collection and storage consumable products on trace element quantitative analysis. Devices and consumable products of different brands used in specimen collection or storage were selected and treated separately as below:urine collection and storage tubes (Brand A, B, C and D, 2 samples for each brand) were treated with 1% of HNO(3) volume fraction for 2 - 4 h; blood taking device (Brand O, P and Q, 3 samples for each brand) were used for ultra-pure water samples collecting as simulation of blood sampling;dust sampling filters (Brand X, Y and Z, 2 samples for each brand) were cold digested by nitric acid for 12 h, followed by microwave digestion. Then cadmium, cobalt, chromium, copper, iron, manganese, molybdenum, nickel, lead, selenium, stannum, titanium, vanadium and zinc concentrations in the solutions obtained during the course of collect or storage were quantified by inductively coupled plasma mass spectrometer. For the urine collection and storage consumable products, background values of elements were described as mean of parellel samples. The consentration of 14 quantified elements were relatively low for 5 ml cryogenic vials (brand B) with background values range of 0.001 - 0.350 ng/ml. The background values of copper of 50 ml centrifuge tubes (brand A), chromium of 5 ml cryogenic vials (brand C) and zinc of 1.5 ml centrifuge tubes (brand D) were relatively high, which were 1.900, 1.095 and 1.368 ng/ml, respectively. Background values of elements in blood sampling devices were described as x(-) ± s. Background values of chromium for brand O, P and Q were (0.120 ± 0.017), (0.337 ± 0.093) and (0.360 ± 0.035) ng/ml; for copper were (0.050 ± 0.001), (0.017 ± 0.012) and (0.103 ± 0.015) ng/ml; for lead were (0.057 ± 0.072), (0.183 ± 0.118) and (0.347 ± 0.006) ng/ml; for titanium were (7.883 ± 0.145), (8.863 ± 0.190) and (8.613 ± 0.274) ng/ml; zinc were (2.240 ± 0.573), (42.140 ± 22.756) and (8

  13. Intact glycopeptide characterization using mass spectrometry

    OpenAIRE

    Cao, Li; Qu, Yi; Zhang, Zhaorui; Wang, Zhe; Prykova, Iya; Wu, Si

    2016-01-01

    Glycosylation is one of the most prominent and extensively studied protein post-translational modifications. However, traditional proteomic studies at the peptide level (bottom-up) rarely characterize intact glycopeptides (glycosylated peptides without removing glycans), so no glycoprotein heterogeneity information is retained. Intact glycopeptide characterization, on the other hand, provides opportunities to simultaneously elucidate the glycan structure and the glycosylation site needed to r...

  14. Specimen-based modeling, stopping rules, and the extinction of the Ivory-Billed Woodpecker

    DEFF Research Database (Denmark)

    Gotelli, Nicholas J.; Chao, Anne; Colwell, Robert K.

    2012-01-01

    Assessing species survival status is an essential component of conservation programs. We devised a new statistical method for estimating the probability of species persistence from the temporal sequence of collection dates of museum specimens. To complement this approach, we developed quantitative...... (Campephilus principalis), long assumed to have become extinct in the United States in the 1950s, but reportedly rediscovered in 2004. We analyzed the temporal pattern of the collection dates of 239 geo-referenced museum specimens collected throughout the southeastern United States from 1853 to 1932...

  15. Consistency and reproducibility of next-generation sequencing and other multigene mutational assays: A worldwide ring trial study on quantitative cytological molecular reference specimens.

    Science.gov (United States)

    Malapelle, Umberto; Mayo-de-Las-Casas, Clara; Molina-Vila, Miguel A; Rosell, Rafael; Savic, Spasenija; Bihl, Michel; Bubendorf, Lukas; Salto-Tellez, Manuel; de Biase, Dario; Tallini, Giovanni; Hwang, David H; Sholl, Lynette M; Luthra, Rajyalakshmi; Weynand, Birgit; Vander Borght, Sara; Missiaglia, Edoardo; Bongiovanni, Massimo; Stieber, Daniel; Vielh, Philippe; Schmitt, Fernando; Rappa, Alessandra; Barberis, Massimo; Pepe, Francesco; Pisapia, Pasquale; Serra, Nicola; Vigliar, Elena; Bellevicine, Claudio; Fassan, Matteo; Rugge, Massimo; de Andrea, Carlos E; Lozano, Maria D; Basolo, Fulvio; Fontanini, Gabriella; Nikiforov, Yuri E; Kamel-Reid, Suzanne; da Cunha Santos, Gilda; Nikiforova, Marina N; Roy-Chowdhuri, Sinchita; Troncone, Giancarlo

    2017-08-01

    Molecular testing of cytological lung cancer specimens includes, beyond epidermal growth factor receptor (EGFR), emerging predictive/prognostic genomic biomarkers such as Kirsten rat sarcoma viral oncogene homolog (KRAS), neuroblastoma RAS viral [v-ras] oncogene homolog (NRAS), B-Raf proto-oncogene, serine/threonine kinase (BRAF), and phosphatidylinositol-4,5-bisphosphate 3-kinase catalytic subunit α (PIK3CA). Next-generation sequencing (NGS) and other multigene mutational assays are suitable for cytological specimens, including smears. However, the current literature reflects single-institution studies rather than multicenter experiences. Quantitative cytological molecular reference slides were produced with cell lines designed to harbor concurrent mutations in the EGFR, KRAS, NRAS, BRAF, and PIK3CA genes at various allelic ratios, including low allele frequencies (AFs; 1%). This interlaboratory ring trial study included 14 institutions across the world that performed multigene mutational assays, from tissue extraction to data analysis, on these reference slides, with each laboratory using its own mutation analysis platform and methodology. All laboratories using NGS (n = 11) successfully detected the study's set of mutations with minimal variations in the means and standard errors of variant fractions at dilution points of 10% (P = .171) and 5% (P = .063) despite the use of different sequencing platforms (Illumina, Ion Torrent/Proton, and Roche). However, when mutations at a low AF of 1% were analyzed, the concordance of the NGS results was low, and this reflected the use of different thresholds for variant calling among the institutions. In contrast, laboratories using matrix-assisted laser desorption/ionization-time of flight (n = 2) showed lower concordance in terms of mutation detection and mutant AF quantification. Quantitative molecular reference slides are a useful tool for monitoring the performance of different multigene mutational

  16. Impact of specimen adequacy on the assessment of renal allograft biopsy specimens.

    Science.gov (United States)

    Cimen, S; Geldenhuys, L; Guler, S; Imamoglu, A; Molinari, M

    2016-01-01

    The Banff classification was introduced to achieve uniformity in the assessment of renal allograft biopsies. The primary aim of this study was to evaluate the impact of specimen adequacy on the Banff classification. All renal allograft biopsies obtained between July 2010 and June 2012 for suspicion of acute rejection were included. Pre-biopsy clinical data on suspected diagnosis and time from renal transplantation were provided to a nephropathologist who was blinded to the original pathological report. Second pathological readings were compared with the original to assess agreement stratified by specimen adequacy. Cohen's kappa test and Fisher's exact test were used for statistical analyses. Forty-nine specimens were reviewed. Among these specimens, 81.6% were classified as adequate, 6.12% as minimal, and 12.24% as unsatisfactory. The agreement analysis among the first and second readings revealed a kappa value of 0.97. Full agreement between readings was found in 75% of the adequate specimens, 66.7 and 50% for minimal and unsatisfactory specimens, respectively. There was no agreement between readings in 5% of the adequate specimens and 16.7% of the unsatisfactory specimens. For the entire sample full agreement was found in 71.4%, partial agreement in 20.4% and no agreement in 8.2% of the specimens. Statistical analysis using Fisher's exact test yielded a P value above 0.25 showing that - probably due to small sample size - the results were not statistically significant. Specimen adequacy may be a determinant of a diagnostic agreement in renal allograft specimen assessment. While additional studies including larger case numbers are required to further delineate the impact of specimen adequacy on the reliability of histopathological assessments, specimen quality must be considered during clinical decision making while dealing with biopsy reports based on minimal or unsatisfactory specimens.

  17. pGlyco 2.0 enables precision N-glycoproteomics with comprehensive quality control and one-step mass spectrometry for intact glycopeptide identification.

    Science.gov (United States)

    Liu, Ming-Qi; Zeng, Wen-Feng; Fang, Pan; Cao, Wei-Qian; Liu, Chao; Yan, Guo-Quan; Zhang, Yang; Peng, Chao; Wu, Jian-Qiang; Zhang, Xiao-Jin; Tu, Hui-Jun; Chi, Hao; Sun, Rui-Xiang; Cao, Yong; Dong, Meng-Qiu; Jiang, Bi-Yun; Huang, Jiang-Ming; Shen, Hua-Li; Wong, Catherine C L; He, Si-Min; Yang, Peng-Yuan

    2017-09-05

    The precise and large-scale identification of intact glycopeptides is a critical step in glycoproteomics. Owing to the complexity of glycosylation, the current overall throughput, data quality and accessibility of intact glycopeptide identification lack behind those in routine proteomic analyses. Here, we propose a workflow for the precise high-throughput identification of intact N-glycopeptides at the proteome scale using stepped-energy fragmentation and a dedicated search engine. pGlyco 2.0 conducts comprehensive quality control including false discovery rate evaluation at all three levels of matches to glycans, peptides and glycopeptides, improving the current level of accuracy of intact glycopeptide identification. The N-glycoproteome of samples metabolically labeled with 15 N/ 13 C were analyzed quantitatively and utilized to validate the glycopeptide identification, which could be used as a novel benchmark pipeline to compare different search engines. Finally, we report a large-scale glycoproteome dataset consisting of 10,009 distinct site-specific N-glycans on 1988 glycosylation sites from 955 glycoproteins in five mouse tissues.Protein glycosylation is a heterogeneous post-translational modification that generates greater proteomic diversity that is difficult to analyze. Here the authors describe pGlyco 2.0, a workflow for the precise one step identification of intact N-glycopeptides at the proteome scale.

  18. Quantitative analysis of modified proteins and their positional isomers by tandem mass spectrometry: human histone H4.

    Science.gov (United States)

    Pesavento, James J; Mizzen, Craig A; Kelleher, Neil L

    2006-07-01

    Here we show that fragment ion abundances from dissociation of ions created from mixtures of multiply modified histone H4 (11 kDa) or of N-terminal synthetic peptides (2 kDa) correspond to their respective intact ion abundances measured by Fourier transform mass spectrometry. Isomeric mixtures of modified forms of the same protein are resolved and quantitated with a precision of intact protein ions created by electrospray greatly easing many of the systematic biases that more strongly affect small peptides (e.g., differences in ionization efficiency and ion m/z values). The ion fragmentation methods validated here are directly extensible to intact human proteins to derive quantitative information on the highly related and often isomeric protein forms created by combinatorial arrays of posttranslational modifications.

  19. Strategies for Analyzing Data from Intact Groups.

    Science.gov (United States)

    Cross, Lawrence H.; Lane, Carolyn E.

    Action research often necessitates the use of intact groups for the comparison of educational treatments or programs. This paper considers several analytical methods that might be used for such situations when pretest scores indicate that these intact groups differ significantly initially. The methods considered include gain score analysis of…

  20. Small Particles Intact Capture Experiment (SPICE)

    Science.gov (United States)

    Nishioka, Ken-Ji; Carle, G. C.; Bunch, T. E.; Mendez, David J.; Ryder, J. T.

    1994-01-01

    The Small Particles Intact Capture Experiment (SPICE) will develop technologies and engineering techniques necessary to capture nearly intact, uncontaminated cosmic and interplanetary dust particles (IDP's). Successful capture of such particles will benefit the exobiology and planetary science communities by providing particulate samples that may have survived unaltered since the formation of the solar system. Characterization of these particles may contribute fundamental data to our knowledge of how these particles could have formed into our planet Earth and, perhaps, contributed to the beginnings of life. The term 'uncontaminated' means that captured cosmic and IDP particles are free of organic contamination from the capture process and the term 'nearly intact capture' means that their chemical and elemental components are not materially altered during capture. The key to capturing cosmic and IDP particles that are organic-contamination free and nearly intact is the capture medium. Initial screening of capture media included organic foams, multiple thin foil layers, and aerogel (a silica gel); but, with the exception of aerogel, the requirements of no contamination or nearly intact capture were not met. To ensure no contamination of particles in the capture process, high-purity aerogel was chosen. High-purity aerogel results in high clarity (visual clearness), a useful quality in detection and recovery of embedded captured particles from the aerogel. P. Tsou at the Jet Propulsion Laboratory (JPL) originally described the use of aerogel for this purpose and reported laboratory test results. He has flown aerogel as a 'GAS-can Lid' payload on STS-47 and is evaluating the results. The Timeband Capture Cell Experiment (TICCE), a Eureca 1 experiment, is also flying aerogel and is scheduled for recovery in late April.

  1. An acceleration test for stress corrosion cracking using humped specimen

    International Nuclear Information System (INIS)

    Kamaya, Masayuki; Fukumura, Takuya; Totsuka, Nobuo

    2003-01-01

    By using the humped specimen, which is processed by the humped die, in the slow strain rate technique (SSRT) test, fracture facet due to stress corrosion cracking (SCC) can be observed in relatively short duration. Although the cold work and concentrated stress and strain caused by the characteristic shape of the specimen accelerate the SCC, to date these acceleration effects have not been examined quantitatively. In the present study, the acceleration effects of the humped specimen were examined through experiments and finite element analyses (FEA). The experiments investigated the SCC of alloy 600 in the primary water environment of a pressurized water reactor. SSRT tests were conducted using two kinds of humped specimen: one was annealed after hump processing in order to eliminate the cold work, and the other was hump processed after the annealing treatment. The work ratio caused by the hump processing and stress/strain conditions during SSRT test were evaluated by FEA. It was found that maximum work ratio of 30% is introduced by the hump processing and that the distribution of the work ratio is not uniform. Furthermore, the work ratio is influenced by the friction between the specimen and dies as well as by the shape of dies. It was revealed that not only the cold work but also the concentrated stress and strain during SSRT test accelerate the crack initiation and growth of the SCC. (author)

  2. 50 CFR 622.38 - Landing fish intact.

    Science.gov (United States)

    2010-10-01

    ... that is operating under the respective trip limits. Such cut-off fish also may be sold. A maximum of... 50 Wildlife and Fisheries 8 2010-10-01 2010-10-01 false Landing fish intact. 622.38 Section 622.38... Landing fish intact. The operator of a vessel that fishes in the EEZ is responsible for ensuring that fish...

  3. Clinical evaluation of a mobile digital specimen radiography system for intraoperative specimen verification.

    Science.gov (United States)

    Wang, Yingbing; Ebuoma, Lilian; Saksena, Mansi; Liu, Bob; Specht, Michelle; Rafferty, Elizabeth

    2014-08-01

    Use of mobile digital specimen radiography systems expedites intraoperative verification of excised breast specimens. The purpose of this study was to evaluate the performance of a such a system for verifying targets. A retrospective review included 100 consecutive pairs of breast specimen radiographs. Specimens were imaged in the operating room with a mobile digital specimen radiography system and then with a conventional digital mammography system in the radiology department. Two expert reviewers independently scored each image for image quality on a 3-point scale and confidence in target visualization on a 5-point scale. A target was considered confidently verified only if both reviewers declared the target to be confidently detected. The 100 specimens contained a total of 174 targets, including 85 clips (49%), 53 calcifications (30%), 35 masses (20%), and one architectural distortion (1%). Although a significantly higher percentage of mobile digital specimen radiographs were considered poor quality by at least one reviewer (25%) compared with conventional digital mammograms (1%), 169 targets (97%), were confidently verified with mobile specimen radiography; 172 targets (98%) were verified with conventional digital mammography. Three faint masses were not confidently verified with mobile specimen radiography, and conventional digital mammography was needed for confirmation. One faint mass and one architectural distortion were not confidently verified with either method. Mobile digital specimen radiography allows high diagnostic confidence for verification of target excision in breast specimens across target types, despite lower image quality. Substituting this modality for conventional digital mammography can eliminate delays associated with specimen transport, potentially decreasing surgical duration and increasing operating room throughput.

  4. Effects of hydrolysed casein, intact casein and intact whey protein on energy expenditure and appetite regulation

    DEFF Research Database (Denmark)

    Bendtsen, Line Quist; Lorenzen, Janne Kunchel; Gomes, Sisse

    2014-01-01

    Casein and whey differ in amino acid composition and in the rate of absorption; however, the absorption rate of casein can be increased to mimic that of whey by exogenous hydrolysis. The objective of the present study was to compare the effects of hydrolysed casein (HC), intact casein (IC......) and intact whey (IW) on energy expenditure (EE) and appetite regulation, and thereby to investigate the influence of amino acid composition and the rate of absorption. In the present randomised cross-over study, twenty-four overweight and moderately obese young men and women consumed three isoenergetic...

  5. Pharmacokinetics of erythropoietin in intact and anephric dogs

    International Nuclear Information System (INIS)

    Fu, J.S.; Lertora, J.J.; Brookins, J.; Rice, J.C.; Fisher, J.W.

    1988-01-01

    The present studies were performed to determine the pharmacokinetic parameters of erythropoietin in intact and anephric dogs by use of unlabeled crude native erythropoietin (nEp) and iodine 125-labeled purified recombinant erythropoietin (rEp) given by intravenous infusion for 15 minutes. Sephadex G-75 gel filtration was used to confirm that the 125I-rEp molecule remained iodinated in dog plasma during the 24-hour period of these studies. The plasma disappearance of erythropoietin conformed to a biexponential equation for both nEp and 125I-rEp, with the central compartment being larger than the peripheral compartment. The mean distribution half-life of 75.3 +/- 21.2 minutes for nEp was significantly (p less than 0.05) longer than that of 125I-rEp (23.7 +/- 5.0 minutes) in intact dogs. The intercompartmental clearance (CIic) for nEp (0.018 +/- 0.006 L/kg/hr) was significantly smaller than that of 125I-rEp (0.068 +/- 0.018 L/kg/hr) in intact dogs (p less than 0.05). There were no significant differences in apparent volume of distribution, elimination half-life, and elimination clearance (CIe) for nEp and rEp in intact dogs. The mean elimination half-life for 125I-rEp in intact dogs (9.0 +/- 0.6 hours) and anephric dogs (13.8 +/- 1.4 hours) was significantly different (p less than 0.05). The CIe for 125I-rEp in anephric dogs (0.008 +/- 0.001 L/kg/hr) was significantly (p less than 0.05) smaller than that of 125I-rEp in intact dogs (0.011 +/- 0.001 L/kg/hr). There were no significant differences in apparent volume of distribution, distribution half-life, and CIic for 125I-rEp in intact and anephric dogs

  6. Comparison of real-time and quantitative polymerase chain reaction assays in detection of cytomegalovirus DNA in clinical specimens

    International Nuclear Information System (INIS)

    Gokahmetoglu, S.; Deniz, E.

    2007-01-01

    To compare the real-time (RT) and qualitative (Q) polymerase chain reaction (PCR) assays for detection of Cytomegalovirus (CMV) DNA. The study took place in the Department of Microbiology, Erciyes University, Kayseri and in Iontek Laboratory, Istanbul, Turkey, from August to December 2006. One hundred and seven clinical specimens from 67 patients were included in the study. Cytomegalovirus DNA was investigated using RT-PCR kit (Fluorion Iontek, Turkey) and Q-PCR kit (Fluorion Iontek, Turkey). Deoxyribonucleic acid sequencing was applied to the samples that yielded discrepant results in both assays. Mac Nema's Chi Square test was used for statistical analysis. Of the specimens, 27 were found positive with both assays: 9 with only RT-PCR, and 11 with only Q-PCR assay. Both assays were found negative in 60 of the specimens. There was a good agreement between the 2 assays in 87(81.3%) of the specimens. There was no statistical significant difference between the assays (p>0.05). Two of the 11 samples that RT-PCR negative Q-PCR positive, and 3 of 9 samples that RT-PCR positive Q-PCR negative were found to be CMV DNA positive by DNA sequencing. A good level of concordance between RT-PCR and Q-PCR assays for CMV DNA detection has been found. (author)

  7. Variable-angle total internal reflection fluorescence microscopy of intact cells of Arabidopsis thaliana

    Directory of Open Access Journals (Sweden)

    Kim Myung K

    2011-09-01

    Full Text Available Abstract Background Total internal reflection fluorescence microscopy (TIRFM is a powerful tool for observing fluorescently labeled molecules on the plasma membrane surface of animal cells. However, the utility of TIRFM in plant cell studies has been limited by the fact that plants have cell walls, thick peripheral layers surrounding the plasma membrane. Recently, a new technique known as variable-angle epifluorescence microscopy (VAEM was developed to circumvent this problem. However, the lack of a detailed analysis of the optical principles underlying VAEM has limited its applications in plant-cell biology. Results Here, we present theoretical and experimental evidence supporting the use of variable-angle TIRFM in observations of intact plant cells. We show that when total internal reflection occurs at the cell wall/cytosol interface with an appropriate angle of incidence, an evanescent wave field of constant depth is produced inside the cytosol. Results of experimental TIRFM observations of the dynamic behaviors of phototropin 1 (a membrane receptor protein and clathrin light chain (a vesicle coat protein support our theoretical analysis. Conclusions These findings demonstrate that variable-angle TIRFM is appropriate for quantitative live imaging of cells in intact tissues of Arabidopsis thaliana.

  8. Isolation of intact elastin fibers devoid of microfibrils.

    NARCIS (Netherlands)

    Daamen, W.F.; Hafmans, T.G.M.; Veerkamp, J.H.; Kuppevelt, A.H.M.S.M. van

    2005-01-01

    Purification protocols for elastin generally result in greatly damaged elastin fibers and this likely influences the biological response. We here describe a novel protocol for the isolation of elastin whereby the fibers stay intact, and introduce the term "elastin fiber" for intact elastic fibers

  9. Surface plasmon resonance sensing: from purified biomolecules to intact cells.

    Science.gov (United States)

    Su, Yu-Wen; Wang, Wei

    2018-04-12

    Surface plasmon resonance (SPR) has become a well-recognized label-free technique for measuring the binding kinetics between biomolecules since the invention of the first SPR-based immunosensor in 1980s. The most popular and traditional format for SPR analysis is to monitor the real-time optical signals when a solution containing ligand molecules is flowing over a sensor substrate functionalized with purified receptor molecules. In recent years, rapid development of several kinds of SPR imaging techniques have allowed for mapping the dynamic distribution of local mass density within single living cells with high spatial and temporal resolutions and reliable sensitivity. Such capability immediately enabled one to investigate the interaction between important biomolecules and intact cells in a label-free, quantitative, and single cell manner, leading to an exciting new trend of cell-based SPR bioanalysis. In this Trend Article, we first describe the principle and technical features of two types of SPR imaging techniques based on prism and objective, respectively. Then we survey the intact cell-based applications in both fundamental cell biology and drug discovery. We conclude the article with comments and perspectives on the future developments. Graphical abstract Recent developments in surface plasmon resonance (SPR) imaging techniques allow for label-free mapping the mass-distribution within single living cells, leading to great expansions in biomolecular interactions studies from homogeneous substrates functionalized with purified biomolecules to heterogeneous substrates containing individual living cells.

  10. Quantitative estimation of hydrogen concentration on the Ni3Al specimens surface in the process of hydrogen release

    International Nuclear Information System (INIS)

    Katano, Gen; Sano, Shogo; Saito, Hideo; Mori, Minoru

    2000-01-01

    The method to calculate the hydrogen concentration in metal specimens is given by tritium counts with the liquid scintillation counter. As segments to measure, Ni 3 Al intermetallic compound crystals were used. Tritium was charged to crystals with the method of cathode charging. The charged tritium was transported by diffusion and released from specimen surface. The tritium releasing rate was calculated from the increasing rate of tritium activity. Then the concentration of hydrogen at the surface was calculated from tritium counts. The outcome showed that the hydrogen concentration decreases at specimens surface by elapsed time. Then, the behavior of tritium diffusion was affected by doped boron (up to 0.235 atom% B and 0.470 atom% B) in Ni 3 Al crystals. As the amount of boron increased, the tritium diffusion coefficient decreased. And the hydrogen concentration varied with the amount of boron. After passing enough time, the hydrogen concentration in crystals with boron was much larger than the one without boron. Since it is very likely that the hydrogen concentration is affected by the number of hydrogen sites in the crystal, it is obvious judging by these phenomena, that by doping boron, numbers of hydrogen trapping sites were created. As the hydrogen distribution becomes homogenous after passing enough time, it is possible to measure the hydrogen concentration in all the crystals from β-ray counts at specimens surface. (author)

  11. New approach to measure soil particulate organic matter in intact samples using X-ray computed micro-tomography

    Science.gov (United States)

    Kravchenko, Alexandra; Negassa, Wakene; Guber, Andrey; Schmidt, Sonja

    2014-05-01

    Particulate soil organic matter (POM) is biologically and chemically active fraction of soil organic matter. It is a source of many agricultural and ecological benefits, among which are POM's contribution to C sequestration. Most of conventional research methods for studying organic matter dynamics involve measurements conducted on pre-processed i.e., ground and sieved soil samples. Unfortunately, grinding and sieving completely destroys soil structure, the component crucial for soil functioning and C protection. Importance of a better understanding of the role of soil structure and of the physical protection that it provides to soil C cannot be overstated; and analysis of quantities, characteristics, and decomposition rates of POM in soil samples with intact structure is among the key elements of gaining such understanding. However, a marked difficulty hindering the progress in such analyses is a lack of tools for identification and quantitative analysis of POM in intact soil samples. Recent advancement in applications of X-ray computed micro-tomography (μ-CT) to soil science has given an opportunity to conduct such analyses. The objective of the current study is to develop a procedure for identification and quantitative characterization of POM within intact soil samples using X-ray μ-CT images and to test performance of the proposed procedure on a set of multiple intact soil macro-aggregates. We used 16 4-6 mm soil aggregates collected at 0-15 cm depth from a Typic Hapludalf soil at multiple field sites with diverse agricultural management history. The aggregates have been scanned at SIMBIOS Centre, Dundee, Scotland at 10 micron resolution. POM was determined from the aggregate images using the developed procedure. The procedure was based on combining image pre-processing steps with discriminant analysis classification. The first component of the procedure consisted of image pre-processing steps based on the range of gray values (GV) along with shape and size

  12. Quantitation of estrogen receptor in seventy-five specimens of breast cancer: comparison between an immunoassay (Abbott ER-EIA monoclonal) and a [3H]estradiol binding assay based on isoelectric focusing in polyacrylamide gel

    International Nuclear Information System (INIS)

    Pousette, A.; Gustafsson, S.A.; Thoernblad, A.M.N.; Nordgren, A.; Saellstroem, J.Li.; Lindgren, A.; Sundelin, P.; Gustafsson, J.A.

    1986-01-01

    Quantitation of estrogen receptor has been performed in cytosol prepared from 75 specimens of breast cancer tissue from patients who had not received hormonal therapy. The study was performed in order to compare an immunoassay (Abbott Laboratories, North Chicago, IL) with our currently used method for estrogen receptor analysis based on isoelectric focusing of [ 3 H]estradiol-receptor complex in polyacrylamide gels. Using linear regression analysis, a regression coefficient (slope) of 1.30 and a correlation coefficient of 0.75 were calculated. The differences in results between the two methods are probably partly explained by the fact that the ligand-based method only measures unoccupied receptor, whereas the immunoassay detects the total amount of receptor, resulting in generally slightly higher concentrations with the latter method. However, in five of 75 specimens the ligand-based method gave a considerably higher concentration of estrogen receptor. This was most probably explained by partial proteolysis resulting in the formation of receptor fragment(s), which was undetectable with the immunoassay but detectable with the ligand-based method. These observations underline the importance of careful handling of specimens during the whole immunoassay procedure

  13. Feasibility in multispectral imaging for predicting the content of bioactive compounds in intact tomato fruit.

    Science.gov (United States)

    Liu, Changhong; Liu, Wei; Chen, Wei; Yang, Jianbo; Zheng, Lei

    2015-04-15

    Tomato is an important health-stimulating fruit because of the antioxidant properties of its main bioactive compounds, dominantly lycopene and phenolic compounds. Nowadays, product differentiation in the fruit market requires an accurate evaluation of these value-added compounds. An experiment was conducted to simultaneously and non-destructively measure lycopene and phenolic compounds content in intact tomatoes using multispectral imaging combined with chemometric methods. Partial least squares (PLS), least squares-support vector machines (LS-SVM) and back propagation neural network (BPNN) were applied to develop quantitative models. Compared with PLS and LS-SVM, BPNN model considerably improved the performance with coefficient of determination in prediction (RP(2))=0.938 and 0.965, residual predictive deviation (RPD)=4.590 and 9.335 for lycopene and total phenolics content prediction, respectively. It is concluded that multispectral imaging is an attractive alternative to the standard methods for determination of bioactive compounds content in intact tomatoes, providing a useful platform for infield fruit sorting/grading. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. The anterior borders of the clavicle and the acromion are not always aligned in the intact acromioclavicular joint: a cadaveric study.

    Science.gov (United States)

    Barth, Johannes; Boutsiadis, Achilleas; Narbona, Pablo; Lädermann, Alexandre; Arrigoni, Paolo; Adams, Christopher R; Burkhart, Stephen S; Denard, Patrick J

    2017-07-01

    The aim of this study was to find reliable anatomic landmarks of the normal acromioclavicular joint (ACJ) that could enable the precise evaluation of the horizontal displacement of the clavicle after dislocation. The hypothesis was that the anterior borders of the acromion and the clavicle are always aligned in intact ACJs. In 30 cadaveric specimens, the anterior and posterior borders of the ACJ's articular facets and the most prominent anterior and posterior bony landmarks of the acromion and the clavicle were identified. The anterior and posterior overhang of the acromion and the clavicle was measured in relation to the borders of the articular facets. Therefore, the possible anterior and posterior alignment of the ACJ was evaluated. Anteriorly, only 18 ACJs (60%) were aligned whereas 7 (24%) had major overhang of the acromion and 3 (10%) had major overhang of the clavicle. Similarly, 18 cases (60%) were posteriorly aligned, whereas 6 (20%) had major clavicular overhang and 4 (14%) had major overhang of the acromion. In 78% of these cases, the ACJ was aligned as well anteriorly as posteriorly (P < .001). Finally, the larger the width of the acromion (P = .032) or the clavicle (P = .049), the better the posterior joint alignment. Our hypothesis was not verified. The acromion and clavicle are not perfectly aligned in a significant number of specimens with intact ACJs (40% of cases). The most reliable landmarks remain their articular facets. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  15. 16 CFR Figure 3 to Part 1610 - Specimen Holder Supported in Specimen Rack

    Science.gov (United States)

    2010-01-01

    ... 16 Commercial Practices 2 2010-01-01 2010-01-01 false Specimen Holder Supported in Specimen Rack 3 Figure 3 to Part 1610 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION FLAMMABLE FABRICS ACT... Holder Supported in Specimen Rack ER25MR08.002 ...

  16. Sequencing historical specimens: successful preparation of small specimens with low amounts of degraded DNA.

    Science.gov (United States)

    Sproul, John S; Maddison, David R

    2017-11-01

    Despite advances that allow DNA sequencing of old museum specimens, sequencing small-bodied, historical specimens can be challenging and unreliable as many contain only small amounts of fragmented DNA. Dependable methods to sequence such specimens are especially critical if the specimens are unique. We attempt to sequence small-bodied (3-6 mm) historical specimens (including nomenclatural types) of beetles that have been housed, dried, in museums for 58-159 years, and for which few or no suitable replacement specimens exist. To better understand ideal approaches of sample preparation and produce preparation guidelines, we compared different library preparation protocols using low amounts of input DNA (1-10 ng). We also explored low-cost optimizations designed to improve library preparation efficiency and sequencing success of historical specimens with minimal DNA, such as enzymatic repair of DNA. We report successful sample preparation and sequencing for all historical specimens despite our low-input DNA approach. We provide a list of guidelines related to DNA repair, bead handling, reducing adapter dimers and library amplification. We present these guidelines to facilitate more economical use of valuable DNA and enable more consistent results in projects that aim to sequence challenging, irreplaceable historical specimens. © 2017 John Wiley & Sons Ltd.

  17. Autism Spectrum Disorder and intact executive functioning.

    Science.gov (United States)

    Ferrara, R; Ansermet, F; Massoni, F; Petrone, L; Onofri, E; Ricci, P; Archer, T; Ricci, S

    2016-01-01

    Earliest notions concerning autism (Autism Spectrum Disorders, ASD) describe the disturbance in executive functioning. Despite altered definition, executive functioning, expressed as higher cognitive skills required complex behaviors linked to the prefrontal cortex, are defective in autism. Specific difficulties in children presenting autism or verbal disabilities at executive functioning levels have been identified. Nevertheless, the developmental deficit of executive functioning in autism is highly diversified with huge individual variation and may even be absent. The aim of the present study to examine the current standing of intact executive functioning intact in ASD. Analysis of ASD populations, whether high-functioning, Asperger's or autism Broad Phenotype, studied over a range of executive functions including response inhibition, planning, cognitive flexibility, cognitive inhibition, and alerting networks indicates an absence of damage/impairment compared to the typically-developed normal control subjects. These findings of intact executive functioning in ASD subjects provide a strong foundation on which to construct applications for growth environments and the rehabilitation of autistic subjects.

  18. Splitting tests on rock specimens

    Energy Technology Data Exchange (ETDEWEB)

    Davies, J D; Stagg, K G

    1970-01-01

    Splitting tests are described for a square-section sandstone specimens line loaded through steel or timber packings on the top face and supported on the bottom face either on similar packings (type A specimen) or directly on the lower platen plate of the testing machine (type B specimens). The stress distribution across the vertical central plane and the horizontal central plane were determined from a linear elastic finite element analysis for both types. Two solutions were obtained for the type B specimen: one assuming no friction between the base of the specimen and the platen plate and the other assuming no relative slip between the surfaces. Vertical and horizontal strains were measured at the center of the specimens for all loads up to failure.

  19. Laparoscopic specimen retrieval bags.

    Science.gov (United States)

    Smorgick, Noam

    2014-10-01

    Specimen retrieval bags have long been used in laparoscopic gynecologic surgery for contained removal of adnexal cysts and masses. More recently, the concerns regarding spread of malignant cells during mechanical morcellation of myoma have led to an additional use of specimen retrieval bags for contained "in-bag" morcellation. This review will discuss the indications for use retrieval bags in gynecologic endoscopy, and describe the different specimen bags available to date.

  20. Quantitative measurement of mean inner potential and specimen thickness from high-resolution off-axis electron holograms of ultra-thin layered WSe2.

    Science.gov (United States)

    Winkler, Florian; Tavabi, Amir H; Barthel, Juri; Duchamp, Martial; Yucelen, Emrah; Borghardt, Sven; Kardynal, Beata E; Dunin-Borkowski, Rafal E

    2017-07-01

    The phase and amplitude of the electron wavefunction that has passed through ultra-thin flakes of WSe 2 is measured from high-resolution off-axis electron holograms. Both the experimental measurements and corresponding computer simulations are used to show that, as a result of dynamical diffraction, the spatially averaged phase does not increase linearly with specimen thickness close to an [001] zone axis orientation even when the specimen has a thickness of only a few layers. It is then not possible to infer the local specimen thickness of the WSe 2 from either the phase or the amplitude alone. Instead, we show that the combined analysis of phase and amplitude from experimental measurements and simulations allows an accurate determination of the local specimen thickness. The relationship between phase and projected potential is shown to be approximately linear for extremely thin specimens that are tilted by several degrees in certain directions from the [001] zone axis. A knowledge of the specimen thickness then allows the electrostatic potential to be determined from the measured phase. By using this combined approach, we determine a value for the mean inner potential of WSe 2 of 18.9±0.8V, which is 12% lower than the value calculated from neutral atom scattering factors. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    Science.gov (United States)

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  2. Urine culture - catheterized specimen

    Science.gov (United States)

    Culture - urine - catheterized specimen; Urine culture - catheterization; Catheterized urine specimen culture ... urinary tract infections may be found in the culture. This is called a contaminant. You may not ...

  3. HMSRP Hawaiian Monk Seal Specimen Data (includes physical specimens, collection information, status, storage locations, and laboratory results associated with individual specimens)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — This data set includes physical specimens, paper logs and Freezerworks database of all logged information on specimens collected from Hawaiian monk seals since 1975....

  4. Intact collagen and atelocollagen sponges: Characterization and ESEM observation

    International Nuclear Information System (INIS)

    Ruozi, Barbara; Tosi, Giovanni; Leo, Eliana; Parma, Bruna; Vismara, Susanna; Forni, Flavio; Vandelli, Maria Angela

    2007-01-01

    In this study we have investigated the chemical-physical and morphological properties of intact and atelocollagen sponges used for tissue engineering. The porous sponges were prepared by lyophilization and their physico-chemical characteristics (water binding capacity, denaturing temperature, amino group content) were investigated. Considering the importance of the 'in vivo' interactions between these sponges and the tissue, our attention was addressed (a) to clarify the relationships between the morphology and the amount of water absorbed and (b) to evaluate the influence of pepsin-alkaline treatment on the reorganization of the atelocollagen fibres. Conventional scanning electron microscopy (SEM) and environmental scanning electron microscopy (ESEM) were employed to study the morphology and wetting behaviour of the intact and atelocollagen sponges. The observations by SEM indicated remarkable differences both in the structure and dimension of the pores between intact and atelocollagen sponges. At the data are related to a different water binding capacity. However, the ESEM observations, achieved by changing the relative humidity in the operative chamber, demonstrated that the water adsorbed can be removed with major difficulty from atelocollagen sponges than from intact ones

  5. Possible applications of energy-dispersive powder diffractometry in the phase analysis of metallurgical and geological specimens

    International Nuclear Information System (INIS)

    Koch, S.; Jugelt, P.

    1978-01-01

    Energy-dispersive powder diffractometry renders possible nondestructive quantitative determination of both α and γ phases of iron with shorter measuring time as compared to angle-dispersive techniques. In investigating geological specimens above all the possibility of obtaining qualitative survey analyses within short time is advantageous. The comparatively lower separability leads to difficulties because of increased line density. Therefore, quantitative phase analysis requires the use of spectra unfolding programmes. For laboratory analyses it is advantageous that the same measuring equipment allows the performance of multi-element analyses. (author)

  6. Evaluation of Intraosseous Fluid as an Alternative Biological Specimen in Postmortem Toxicology.

    Science.gov (United States)

    Rodda, Luke N; Volk, Justin A; Moffat, Ellen; Williams, Chinyere M; Lynch, Kara L; Wu, Alan H B

    2018-04-01

    The postmortem redistribution phenomenon is an important factor in the interpretation of blood drug concentrations as a cause or factor in death. Intraosseous fluid (IOF) may serve as an alternative matrix for drug testing. Intraosseous fluid was collected from the left and right tibias and humerus of 29 decedents using the Arrow EZ-IO Intraosseous Vascular Access System. Standard autopsy specimens including blood were also collected at the same time during autopsy. Blood and IOF specimens were screened by immunoassay for opioids, fentanyl analogs, oxycodone, methadone, cocaine, methamphetamine, amphetamines, phencyclidine, tricyclic antidepressants, benzodiazepines and cannabinoids, using commercially available enzyme-linked immunosorbent assay (ELISA) kits. Correlation between cardiac/central blood ELISA and IOF ELISA results was mostly 100% for drug targets. Further blood confirmation analysis was performed by gas chromatography mass spectrometry also showed comparable correlation to IOF screen results. There was no significant difference between the IOF sites or sides of the body. This novel study supports the use of IOF as an alternative postmortem specimen for toxicological investigations as a potentially less-compromised tissue in decomposed or traumatized bodies. Preliminary data is provided for the screening of common drugs of abuse in IOF that may show to be subject to alternative rates of postmortem redistribution than to that of other biological specimens in future studies that quantitate IOF drug concentrations.

  7. Quantitative analyses of shrinkage characteristics of neem ...

    African Journals Online (AJOL)

    Quantitative analyses of shrinkage characteristics of neem (Azadirachta indica A. Juss.) wood were carried out. Forty five wood specimens were prepared from the three ecological zones of north eastern Nigeria, viz: sahel savanna, sudan savanna and guinea savanna for the research. The results indicated that the wood ...

  8. Quantitative X-ray analysis of biological fluids: the microdroplet technique

    International Nuclear Information System (INIS)

    Roinel, N.

    1988-01-01

    X-ray microanalysis can be used to quantitatively determine the elemental composition of microvolumes of biological fluids. This article describes the various steps in preparation of microdroplets for analysis: The manufacturing of micropipettes, the preparation of the specimen support, the deposition of droplets on the support, shock-freezing, and lyophilization. Examples of common artifacts (incomplete rehydration prior to freezing or partial rehydration after lyophilization) are demonstrated. Analysis can be carried out either by wavelength-dispersive analysis, which is the most sensitive method, or by energy-dispersive analysis, which is more commonly available. The minimum detectable concentration is 0.05 mmol.liter-1 for 0.1-nl samples analyzed by wavelength-dispersive spectrometry and 0.5-1 mmol.liter-1 for samples analyzed by energy-dispersive spectrometry. A major problem, especially in wavelength-dispersive analysis, where high beam currents are used, is radiation damage to the specimen; in particular chloride (but also other elements) can be lost. Quantitative analysis requires the use of standard solutions with elemental concentration in the same range as those present in the specimen

  9. Measurement of diffusive properties of intact rock

    Energy Technology Data Exchange (ETDEWEB)

    Harvey, K B

    1996-12-01

    In the Postclosure Assessment of a Reference System for the Disposal of Canada`s Nuclear Fuel Waste (Goodwin et al. 1994) the disposal vault is assumed to be surrounded by a zone of intact rock, referred to as the `exclusion zone.` A sensitivity analysis of the relative effectiveness of the several engineered and natural barriers that contribute to the safety of the reference disposal system has shown that this zone of intact rock is the most effective of these barriers to the movement of radionuclides through the reference system. Peer review of the geosphere model used in the case study for the EIS (Environmental Impact Statement) of the Canadian Nuclear Fuel Waste Management Program has identified the need to quantify the properties of the intact rock surrounding the disposal vault that would control the transport of radionuclides by diffusion. The Postclosure Assessment also identified the need for appropriate values of the free water diffusion coefficient (D{sub o}) for {sup 129}1 and {sup 14}C. The measurement of rock resistivity allows the calculation of the Formation Factor for a rock This review describes the Formation Factor, diffusivity, permeability, and porosity, and how these properties might be measured or inferred for insitu rock under the conditions that apply to the intact rock surrounding a potential disposal vault. The importance of measuring the intrinsic diffusion coefficient (D{sup i}) of diffusing species under solution salinities simulating those of groundwaters is emphasised, and a method of measurement is described that is independent of the diffusing medium, and which would be appropriate for measurements made in chemically complex media such as groundwaters. (author). 95 refs., 4 tabs., 39 figs.

  10. Measurement of diffusive properties of intact rock

    International Nuclear Information System (INIS)

    Harvey, K.B.

    1996-12-01

    In the Postclosure Assessment of a Reference System for the Disposal of Canada's Nuclear Fuel Waste (Goodwin et al. 1994) the disposal vault is assumed to be surrounded by a zone of intact rock, referred to as the 'exclusion zone.' A sensitivity analysis of the relative effectiveness of the several engineered and natural barriers that contribute to the safety of the reference disposal system has shown that this zone of intact rock is the most effective of these barriers to the movement of radionuclides through the reference system. Peer review of the geosphere model used in the case study for the EIS (Environmental Impact Statement) of the Canadian Nuclear Fuel Waste Management Program has identified the need to quantify the properties of the intact rock surrounding the disposal vault that would control the transport of radionuclides by diffusion. The Postclosure Assessment also identified the need for appropriate values of the free water diffusion coefficient (D o ) for 129 1 and 14 C. The measurement of rock resistivity allows the calculation of the Formation Factor for a rock This review describes the Formation Factor, diffusivity, permeability, and porosity, and how these properties might be measured or inferred for insitu rock under the conditions that apply to the intact rock surrounding a potential disposal vault. The importance of measuring the intrinsic diffusion coefficient (D i ) of diffusing species under solution salinities simulating those of groundwaters is emphasised, and a method of measurement is described that is independent of the diffusing medium, and which would be appropriate for measurements made in chemically complex media such as groundwaters. (author). 95 refs., 4 tabs., 39 figs

  11. Screen-film specimen radiography

    International Nuclear Information System (INIS)

    Shepard, S.J.; Hogan, J.; Schreck, B.

    1990-01-01

    This paper reports on the reproducibility and quality of biopsy specimen radiographs, a unique phototimed cabinet x-ray system is being developed. The system utilizes specially modified Kodal Min-R cassettes and will be compatible with current mammographic films. Tube voltages are in the 14-20-kVp range with 0.1-1.0-second exposure times. A top-hat type compression device is used (1) to compress the specimen to uniform thickness, (2) to measure the specimen thickness and determine optimum kVp, and (3) to superimpose a grid over the specimen for identification of objects of radiographic interest. The phototiming circuit developed specifically for this purpose will be described along with the modified Min-R cassette. Characteristics of the generator and cabinet will also be described. Tests will be performed on phantoms to evaluate the system limitations

  12. The quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) in human urine specimens, a metabolite of LSD: comparative analysis using liquid chromatography-selected ion monitoring mass spectrometry and liquid chromatography-ion trap mass spectrometry.

    Science.gov (United States)

    Poch, G K; Klette, K L; Anderson, C

    2000-04-01

    This paper compares the potential forensic application of two sensitive and rapid procedures (liquid chromatography-mass spectrometry and liquid chromatography-ion trap mass spectrometry) for the detection and quantitation of 2-oxo-3-hydroxy lysergic acid diethylamide (O-H-LSD) a major LSD metabolite. O-H-LSD calibration curves for both procedures were linear over the concentration range 0-8,000 pg/mL with correlation coefficients (r2) greater than 0.99. The observed limit of detection (LOD) and limit of quantitation (LOQ) for O-H-LSD in both procedures was 400 pg/mL. Sixty-eight human urine specimens that had previously been found to contain LSD by gas chromatography-mass spectrometry were reanalyzed by both procedures for LSD and O-H-LSD. These specimens contained a mean concentration of O-H-LSD approximately 16 times higher than the LSD concentration. Because both LC methods produce similar results, either procedure can be readily adapted to O-H-LSD analysis for use in high-volume drug-testing laboratories. In addition, the possibility of significantly increasing the LSD detection time window by targeting this major LSD metabolite for analysis may influence other drug-free workplace programs to test for LSD.

  13. Quantitative mass spectrometry of unconventional human biological matrices

    Science.gov (United States)

    Dutkiewicz, Ewelina P.; Urban, Pawel L.

    2016-10-01

    The development of sensitive and versatile mass spectrometric methodology has fuelled interest in the analysis of metabolites and drugs in unconventional biological specimens. Here, we discuss the analysis of eight human matrices-hair, nail, breath, saliva, tears, meibum, nasal mucus and skin excretions (including sweat)-by mass spectrometry (MS). The use of such specimens brings a number of advantages, the most important being non-invasive sampling, the limited risk of adulteration and the ability to obtain information that complements blood and urine tests. The most often studied matrices are hair, breath and saliva. This review primarily focuses on endogenous (e.g. potential biomarkers, hormones) and exogenous (e.g. drugs, environmental contaminants) small molecules. The majority of analytical methods used chromatographic separation prior to MS; however, such a hyphenated methodology greatly limits analytical throughput. On the other hand, the mass spectrometric methods that exclude chromatographic separation are fast but suffer from matrix interferences. To enable development of quantitative assays for unconventional matrices, it is desirable to standardize the protocols for the analysis of each specimen and create appropriate certified reference materials. Overcoming these challenges will make analysis of unconventional human biological matrices more common in a clinical setting. This article is part of the themed issue 'Quantitative mass spectrometry'.

  14. Preventive lateral ligament tester (PLLT): a novel method to evaluate mechanical properties of lateral ankle joint ligaments in the intact ankle.

    Science.gov (United States)

    Best, Raymond; Böhle, Caroline; Mauch, Frieder; Brüggemann, Peter G

    2016-04-01

    To construct and evaluate an ankle arthrometer that registers inversion joint deflection at standardized inversion loads and that, moreover, allows conclusions about the mechanical strain of intact ankle joint ligaments at these loads. Twelve healthy ankles and 12 lower limb cadaver specimens were tested in a self-developed measuring device monitoring passive ankle inversion movement (Inv-ROM) at standardized application of inversion loads of 5, 10 and 15 N. To adjust in vivo and in vitro conditions, the muscular inactivity of the evertor muscles was assured by EMG in vivo. Preliminary, test-retest and trial-to-trial reliabilities were tested in vivo. To detect lateral ligament strain, the cadaveric calcaneofibular ligament was instrumented with a buckle transducer. After post-test harvesting of the ligament with its bony attachments, previously obtained resistance strain gauge results were then transferred to tensile loads, mounting the specimens with their buckle transducers into a hydraulic material testing machine. ICC reliability considering the Inv-ROM and torsional stiffness varied between 0.80 and 0.90. Inv-ROM ranged from 15.3° (±7.3°) at 5 N to 28.3° (±7.6) at 15 N. The different tests revealed a CFL tensile load of 31.9 (±14.0) N at 5 N, 51.0 (±15.8) at 10 N and 75.4 (±21.3) N at 15 N inversion load. A highly reliable arthrometer was constructed allowing not only the accurate detection of passive joint deflections at standardized inversion loads but also reveals some objective conclusions of the intact CFL properties in correlation with the individual inversion deflections. The detection of individual joint deflections at predefined loads in correlation with the knowledge of tensile ligament loads in the future could enable more individual preventive measures, e.g., in high-level athletes.

  15. Liver polyribosome distribution in intact and adrenalectomized rats exposed to. gamma. radiation

    Energy Technology Data Exchange (ETDEWEB)

    Yatvin, M B; Abdel-Halim, M N [Wisconsin Univ., Madison (USA). Dept. of Radiology; Wisconsin Univ., Madison (USA). Dept. of Human Oncology)

    1978-06-01

    The mechanism(s) by which gamma radiation influences liver polyribosome distribution was studied in groups of intact and adrenalectomized male rats. A shift from light to heavy aggregates occurred in the polyribosomes of both intact and adrenalectomized rats after they were exposed to gamma rays. In irradiated adrenalectomized rats, however, the shift to heavier aggregates was not as great as that which occurred in irradiated adrenal-intact animals. Subcutaneous injection of cortisone acetate (10 mg/100 g body weight) also altered the liver polyribosome patterns of both intact and adrenalectomized rats within 8 hours of its administration. The shift which occurred following cortisone administration, however, was less striking than that seen after irradiation only. Thus, although adrenal glucocorticoids contribute to the radiation-indu ied shift in liver polyribosomes in adrenal-intact rats, other factors appear to be involved, since the shift is also obtained in adrenalectomized animals.

  16. Janka hardness using nonstandard specimens

    Science.gov (United States)

    David W. Green; Marshall Begel; William Nelson

    2006-01-01

    Janka hardness determined on 1.5- by 3.5-in. specimens (2×4s) was found to be equivalent to that determined using the 2- by 2-in. specimen specified in ASTM D 143. Data are presented on the relationship between Janka hardness and the strength of clear wood. Analysis of historical data determined using standard specimens indicated no difference between side hardness...

  17. Sorption of cesium in intact rock

    International Nuclear Information System (INIS)

    Puukko, E.

    2014-04-01

    The mass distribution coefficient K d is used in performance assessment (PA) to describe sorption of a radionuclide on rock. The R d is determined using crushed rock which causes uncertainty in converting the R d values to K d values for intact rock. This work describes a method to determine the equilibrium of sorption on intact rock. The rock types of the planned Olkiluoto waste disposal site were T-series mica gneiss (T-MGN), T-series tonalite granodiorite granite gneiss (T-TGG), P-series tonalite granodiorite granite gneiss (P-TGG) and pegmatitic granite (PGR). These rocks contain different amount of biotite which is the main sorbing mineral. The sorption of cesium on intact rock slices was studied by applying an electrical field to speed up migration of cesium into the rock. Cesium is in the solution as a noncomplex cation Cs + and it is sorbed by ion exchange. The tracer used in the experiments was 134 Cs. The experimental sorption on the intact rock is compared with values calculated using the in house cation exchange sorption model (HYRL model) in PHREEQC program. The observed sorption on T-MGN and T-TGG rocks was close to the calculated values. Two PGR samples were from a depth of 70 m and three samples were from a depth of 150 m. Cesium sorbed more than predicted on the two 70 m PGR samples. The sorption of Cs on the three 150 m PGR samples was small which was consistent with the calculations. The pegmatitic granite PGR has the smallest content of biotite of the four rock types. In the case of P-TGG rock the observed values of sorption were only half of the calculated values. Two kind of slices were cut from P-TGG drill core. The slices were against and to the direction of the foliation of the biotite rims. The sorption of cesium on P-TGG rock was same in both cases. The results indicated that there was no effect of the directions of the electric field and the foliation of biotite in the P-TGG rock. (orig.)

  18. LPTR irradiation of LLL vanadium tensile specimens and LLL Nb--1Zr tensile specimens

    International Nuclear Information System (INIS)

    MacLean, S.C.; Rowe, C.L.

    1977-01-01

    The LPTR irradiation of 14 LLL vanadium tensile specimens and 14 LLL Nb-1Zr tensile specimens is described. Sample packaging, the irradiation schedule and neutron fluences for three energy ranges are given

  19. Georeferencing Animal Specimen Datasets

    NARCIS (Netherlands)

    van Erp, M.G.J.; Hensel, R.; Ceolin, D.; van der Meij, M.

    2014-01-01

    For biodiversity research, the field of study that is concerned with the richness of species of our planet, it is of the utmost importance that the location of an animal specimen find is known with high precision. Due to specimens often having been collected over the course of many years, their

  20. Imaging with 11B of intact tissues using magnetic resonance gradient echoes

    International Nuclear Information System (INIS)

    Richards, T.L.; Bradshaw, K.M.; Freeman, D.M.; Sotak, C.H.; Gavin, P.R.

    1988-01-01

    Boron neutron capture therapy (BNCT) is a proposed method of treating Glioblastoma Multiforme. BNCT is based on 10 B intake by the tumor and in-situ activation by neutron beam. It is estimated that to have successful BNCT, a 10 B delivery mechanism must deposit 20 ppM or more of 10 B within the tumor. To study and understand this delivery mechanism, 11 B can be used instead of 10 B. The pharmacokinetics of any compound using 11 B will be the same as 10 B. The advantage of using 11 B over 10 B is its greater nuclear magnetic resonance sensitivity for both spectroscopy and imaging. The use of 11 B imaging to detect and quantitate boron uptake non-invasively in animal tumor modes will facilitate continued work with 10 B. Preliminary work has shown that 11 B nuclear magnetic resonance (NMR) spectroscopy (nonlocalized) can detect 11 B in intact mouse tissues and the area under the boron peak correlates with the total boron content (correlation coefficient of 0.997). Once the ability to non-invasively measure the boron compound is established using magnetic resonance imaging (MRI) combined with spectroscopy, we will be able to address the following questions: (1) what is the optimum method of boron administration for maximum tumor selective uptake, (2) at what time is peak tumor boron concentration after infusion, and (3) what is the dose distribution in the head (based on neutron radiation and boron concentration)? The purpose of this study was to test the feasibility of imaging 11 B in intact tissues using magnetic resonance

  1. DNA extraction from herbarium specimens.

    Science.gov (United States)

    Drábková, Lenka Záveská

    2014-01-01

    With the expansion of molecular techniques, the historical collections have become widely used. Studying plant DNA using modern molecular techniques such as DNA sequencing plays an important role in understanding evolutionary relationships, identification through DNA barcoding, conservation status, and many other aspects of plant biology. Enormous herbarium collections are an important source of material especially for specimens from areas difficult to access or from taxa that are now extinct. The ability to utilize these specimens greatly enhances the research. However, the process of extracting DNA from herbarium specimens is often fraught with difficulty related to such variables as plant chemistry, drying method of the specimen, and chemical treatment of the specimen. Although many methods have been developed for extraction of DNA from herbarium specimens, the most frequently used are modified CTAB and DNeasy Plant Mini Kit protocols. Nine selected protocols in this chapter have been successfully used for high-quality DNA extraction from different kinds of plant herbarium tissues. These methods differ primarily with respect to their requirements for input material (from algae to vascular plants), type of the plant tissue (leaves with incrustations, sclerenchyma strands, mucilaginous tissues, needles, seeds), and further possible applications (PCR-based methods or microsatellites, AFLP).

  2. Techniques for the recovery and identification of Cryptosporidium oocysts from stool specimens.

    Science.gov (United States)

    Garcia, L S; Bruckner, D A; Brewer, T C; Shimizu, R Y

    1983-07-01

    Due to increasing numbers of patients with documented infections with Cryptosporidium and other coccidia, it is important for the physician and clinical laboratory to be aware of the appropriate diagnostic techniques necessary for organism recovery and identification. Although Cryptosporidium is found in the gastrointestinal tract, tissue biopsies may be insufficient for organism recovery; the examination of stool specimens is a noninvasive procedure and will provide better overall opportunities for organism recovery. Human clinical specimens were examined from 45 patients with confirmed cryptosporidiosis or suspected of having the infection. Tissue biopsy sections, fecal wet preparations, and permanent stained smears were examined. Stool specimens were submitted in 10% Formalin, 2.5% potassium dichromate, and polyvinyl alcohol and were examined for oocysts by using 15 different methods: phase-contrast and light microscopy; Sheather's sugar flotation; Formalin concentration techniques; 10% potassium hydroxide; Giemsa; trichrome; periodic acid-Schiff; modified periodic acid-Schiff; silver methenamine; acridine orange; auramine-rhodamine; Kinyoun acid-fast; Ziehl-Neelsen carbolfuchsin; and a modified acid-fast procedure. Each technique or combination of techniques was assessed by organism quantitation, organism morphology, and ease of visual recognition. Based on these comparative studies, the modified Ziehl-Neelsen carbolfuchsin stain on 10% Formalin-preserved stool is recommended for the recovery and identification of Cryptosporidium.

  3. Specimen size effects in Charpy impact testing

    International Nuclear Information System (INIS)

    Alexander, D.J.; Klueh, R.L.

    1989-01-01

    Full-size , half-size, and third-size specimens from several different steels have been tested as part of an ongoing alloy development program. The smaller specimens permit more specimens to be made from small trail heats and are much more efficient for irradiation experiments. The results of several comparisons between the different specimen sizes have shown that the smaller specimens show qualitatively similar behavior to large specimens, although the upper-shelf energy level and ductile-to-ductile transition temperature are reduced. The upper-shelf energy levels from different specimen sizes can be compared by using a simple volume normalization method. The effect of specimen size and geometry on the ductile-to-ductile transition temperature is more difficult to predict, although the available data suggest a simple shift in the transition temperature due to specimen size changes.The relatively shallower notch used in smaller specimens alters the deformation pattern, and permits yielding to spread back to the notched surface as well as through to the back. This reduces the constraint and the peak stresses, and thus the initiation of cleavage is more difficult. A better understanding of the stress and strain distributions is needed. 19 refs., 3 figs., 3 tabs

  4. Quantitative optical microscopy: measurement of cellular biophysical features with a standard optical microscope.

    Science.gov (United States)

    Phillips, Kevin G; Baker-Groberg, Sandra M; McCarty, Owen J T

    2014-04-07

    We describe the use of a standard optical microscope to perform quantitative measurements of mass, volume, and density on cellular specimens through a combination of bright field and differential interference contrast imagery. Two primary approaches are presented: noninterferometric quantitative phase microscopy (NIQPM), to perform measurements of total cell mass and subcellular density distribution, and Hilbert transform differential interference contrast microscopy (HTDIC) to determine volume. NIQPM is based on a simplified model of wave propagation, termed the paraxial approximation, with three underlying assumptions: low numerical aperture (NA) illumination, weak scattering, and weak absorption of light by the specimen. Fortunately, unstained cellular specimens satisfy these assumptions and low NA illumination is easily achieved on commercial microscopes. HTDIC is used to obtain volumetric information from through-focus DIC imagery under high NA illumination conditions. High NA illumination enables enhanced sectioning of the specimen along the optical axis. Hilbert transform processing on the DIC image stacks greatly enhances edge detection algorithms for localization of the specimen borders in three dimensions by separating the gray values of the specimen intensity from those of the background. The primary advantages of NIQPM and HTDIC lay in their technological accessibility using "off-the-shelf" microscopes. There are two basic limitations of these methods: slow z-stack acquisition time on commercial scopes currently abrogates the investigation of phenomena faster than 1 frame/minute, and secondly, diffraction effects restrict the utility of NIQPM and HTDIC to objects from 0.2 up to 10 (NIQPM) and 20 (HTDIC) μm in diameter, respectively. Hence, the specimen and its associated time dynamics of interest must meet certain size and temporal constraints to enable the use of these methods. Excitingly, most fixed cellular specimens are readily investigated with

  5. Effect of CT Specimen Thickness on the Mechanical Characteristics at the Crack Tip of Stress Corrosion Cracking in Ni-based Alloys

    Science.gov (United States)

    Yinghao, Cui; He, Xue; Lingyan, Zhao

    2017-12-01

    It’s important to obtain accurate stress corrosion crack(SCC) growth rate for quantitative life prediction of components in nuclear power plants. However, the engineering practice shows that the crack tip constraint effect has a great influence on the mechanical properties and crack growth rate of SCC at crack tip. To study the influence of the specimen thickness on the crack tip mechanical properties of SCC, the stress, strain and C integral at creep crack tip are analyzed under different specimens thickness. Results show that the cracked specimen is less likely to crack due to effect of crack tip constraint. When the thickness ratio B/W is larger than 0.1, the crack tip constraint is almost ineffective. Value of C integral is the largest when B/W is 0.25. Then specimen thickness has little effect on the value of C integral. The effect of specimen thickness on the value of C integral is less significant at higher thickness ratio.

  6. Quantitative phase imaging of arthropods

    Science.gov (United States)

    Sridharan, Shamira; Katz, Aron; Soto-Adames, Felipe; Popescu, Gabriel

    2015-11-01

    Classification of arthropods is performed by characterization of fine features such as setae and cuticles. An unstained whole arthropod specimen mounted on a slide can be preserved for many decades, but is difficult to study since current methods require sample manipulation or tedious image processing. Spatial light interference microscopy (SLIM) is a quantitative phase imaging (QPI) technique that is an add-on module to a commercial phase contrast microscope. We use SLIM to image a whole organism springtail Ceratophysella denticulata mounted on a slide. This is the first time, to our knowledge, that an entire organism has been imaged using QPI. We also demonstrate the ability of SLIM to image fine structures in addition to providing quantitative data that cannot be obtained by traditional bright field microscopy.

  7. Multiplex Quantitative Histologic Analysis of Human Breast Cancer Cell Signaling and Cell Fate

    National Research Council Canada - National Science Library

    Lee, William M; Roysam, Badrinath

    2008-01-01

    .... We are developing a novel platform for immunohistological study of breast cancer specimens that will retrieve multiplex quantitative molecular information about tumor cells at a cytologic level...

  8. Xenopus egg cytoplasm with intact actin.

    Science.gov (United States)

    Field, Christine M; Nguyen, Phuong A; Ishihara, Keisuke; Groen, Aaron C; Mitchison, Timothy J

    2014-01-01

    We report optimized methods for preparing Xenopus egg extracts without cytochalasin D, that we term "actin-intact egg extract." These are undiluted egg cytoplasm that contains abundant organelles, and glycogen which supplies energy, and represents the least perturbed cell-free cytoplasm preparation we know of. We used this system to probe cell cycle regulation of actin and myosin-II dynamics (Field et al., 2011), and to reconstitute the large, interphase asters that organize early Xenopus embryos (Mitchison et al., 2012; Wühr, Tan, Parker, Detrich, & Mitchison, 2010). Actin-intact Xenopus egg extracts are useful for analysis of actin dynamics, and interaction of actin with other cytoplasmic systems, in a cell-free system that closely mimics egg physiology, and more generally for probing the biochemistry and biophysics of the egg, zygote, and early embryo. Detailed protocols are provided along with assays used to check cell cycle state and tips for handling and storing undiluted egg extracts. © 2014 Elsevier Inc. All rights reserved.

  9. Poliovirus surveillance by examining sewage specimens. Quantitative recovery of virus after introduction into sewerage at remote upstream location.

    Science.gov (United States)

    Hovi, T; Stenvik, M; Partanen, H; Kangas, A

    2001-08-01

    In order to assess the feasibility of environmental poliovirus surveillance, known amounts of poliovirus type 1, strain Sabin, were flushed into the sewage network of Helsinki. Grab specimens collected at a remote downstream location and concentrated about a 100-fold revealed infectious poliovirus on four successive days in all three separate experiments. As for concentration, a simple two-phase separation method was found to be at least as useful as a several-fold more resource-demanding polyethylene glycol (PEG) precipitation method. Recovery of the introduced virus was remarkably high (more than 10%). Using the current system, it might be possible to detect poliovirus circulation in a population of 700,000 people by examining a single 400 ml sewage specimen, if 1 out of 10,000 inhabitants were excreting the virus. It is concluded that environmental surveillance is a sensitive approach to monitor silent poliovirus circulation in populations served by a sewage network.

  10. Gel-aided sample preparation (GASP)--a simplified method for gel-assisted proteomic sample generation from protein extracts and intact cells.

    Science.gov (United States)

    Fischer, Roman; Kessler, Benedikt M

    2015-04-01

    We describe a "gel-assisted" proteomic sample preparation method for MS analysis. Solubilized protein extracts or intact cells are copolymerized with acrylamide, facilitating denaturation, reduction, quantitative cysteine alkylation, and matrix formation. Gel-aided sample preparation has been optimized to be highly flexible, scalable, and to allow reproducible sample generation from 50 cells to milligrams of protein extracts. This methodology is fast, sensitive, easy-to-use on a wide range of sample types, and accessible to nonspecialists. © 2014 The Authors. PROTEOMICS published by Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Development of Reconstitution Technology for Surveillance Specimens

    International Nuclear Information System (INIS)

    Yasushi Atago; Shunichi Hatano; Eiichiro Otsuka

    2002-01-01

    The Japan Power Engineering and Inspection Corporation (JAPEIC) has been carrying out the project titled 'Nuclear Power Plant Integrated Management Technology (PLIM)' consigned by Japanese Ministry of Economy, Trade and Industry (METI) since 1996FY as a 10-years project. As one of the project themes, development of reconstitution technology for reactor pressure vessel (RPV/RV) surveillance specimens, which are installed in RPVs to monitor the neutron irradiation embrittlement on RPV/RV materials, is now on being carried out to deal with the long-term operation of nuclear power plants. The target of this theme is to establish the technical standard for applicability of reconstituted surveillance specimens including the reconstitution of the Charpy specimens and Compact Tension (CT) specimens. With the Charpy specimen reconstitution, application of 10 mm length inserts is used, which enables the conversion of tests from the LT-direction to the TL-direction. This paper presents the basic data from Charpy and CT specimens of RPV materials using the surveillance specimens obtained for un-irradiated materials including the following. 1) Reconstitution Technology of Charpy Specimens. a) The interaction between plastic zone and Heat Affected Zone (HAZ). b) The effects of the possible deviations from the standard specimens for the reconstituted specimens. 2) Reconstitution Technology of CT specimens. a) The correlation between fracture toughness and plastic zone width. Because the project is now in progress, this paper describes the outline of the results obtained as of the end of 2000 FY. (authors)

  12. Assessment of geomechanical properties of intact Opalinus Clay - Expert report

    International Nuclear Information System (INIS)

    Amann, F.; Vogelhuber, M.

    2015-11-01

    This comprehensive report published by the Swiss Federal Nuclear Safety Inspectorate ENSI presents an expert report published on the assessment of the geomechanical properties of intact Opalinus Clay. This review report addresses the conceptual constitutive framework for repositories in Opalinus Clay. The author addresses the geomechanical fundamentals that are necessary in order to adequately judge experiments on intact Opalinus Clay and the interpretation of the results. The report assesses in detail the various test series on intact Opalinus Clay carried out along with the interpretations made by experts and NAGRA. Further assessments are quoted including those on sample geometries tested, effective strength properties, undrained shear strength properties and elastic properties. The results of work done by other experts are also presented and discussed. The report is completed with a list of relevant literature

  13. Assessment of geomechanical properties of intact Opalinus Clay - Expert report

    Energy Technology Data Exchange (ETDEWEB)

    Amann, F. [Eidgenössische Technische Hochschule ETHZ, Zürich (Switzerland); Vogelhuber, M. [Dr. von Moos AG, Geotechnisches Büro, Zürich (Switzerland)

    2015-11-15

    This comprehensive report published by the Swiss Federal Nuclear Safety Inspectorate ENSI presents an expert report published on the assessment of the geomechanical properties of intact Opalinus Clay. This review report addresses the conceptual constitutive framework for repositories in Opalinus Clay. The author addresses the geomechanical fundamentals that are necessary in order to adequately judge experiments on intact Opalinus Clay and the interpretation of the results. The report assesses in detail the various test series on intact Opalinus Clay carried out along with the interpretations made by experts and NAGRA. Further assessments are quoted including those on sample geometries tested, effective strength properties, undrained shear strength properties and elastic properties. The results of work done by other experts are also presented and discussed. The report is completed with a list of relevant literature.

  14. Quantitative phase imaging and differential interference contrast imaging for biological TEM

    International Nuclear Information System (INIS)

    Allman, B.E.; McMahon, P.J.; Barone-Nugent, E.D.; Nugent, E.D.

    2002-01-01

    Full text: Phase microscopy is a central technique in science. An experienced microscopist uses this effect to visualise (edge) structure within transparent samples by slightly defocusing the microscope. Although widespread in optical microscopy, phase contrast transmission electron microscopy (TEM) has not been widely adopted. TEM for biological specimens has largely relied on staining techniques to yield sufficient contrast. We show here a simple method for quantitative TEM phase microscopy that quantifies this phase contrast effect. Starting with conventional, digital, bright field images of the sample, our algorithm provides quantitative phase information independent of the sample's bright field intensity image. We present TEM phase images of a range of stained and unstained, biological and material science specimens. This independent phase and intensity information is then used to emulate a range of phase visualisation images familiar to optical microscopy, e.g. differential interference contrast. The phase images contain features not visible with the other imaging modalities. Further, if the TEM samples have been prepared on a microtome to a uniform thickness, the phase information can be converted into refractive index structure of the specimen. Copyright (2002) Australian Society for Electron Microscopy Inc

  15. Developments in quantitative electron probe microanalysis

    International Nuclear Information System (INIS)

    Tixier, R.

    1977-01-01

    A study of the range of validity of the formulae for corrections used with massive specimen analysis is made. The method used is original; we have shown that it was possible to use a property of invariability of corrected intensity ratios for standards. This invariance property provides a test for the self consistency of the theory. The theoretical and experimental conditions required for quantitative electron probe microanalysis of thin transmission electron microscope specimens are examined. The correction formulae for atomic number, absorption and fluorescence effects are calculated. Several examples of experimental results are given, relative to the quantitative analysis of intermetallic precipitates and carbides in steels. Advances in applications of electron probe instruments related to the use of computer and the present development of fully automated instruments are reviewed. The necessary statistics for measurements of X ray count data are studied. Estimation procedure and tests are developed. These methods are used to perform a statistical check of electron probe microanalysis measurements and to reject rogue values. An estimator of the confidence interval of the apparent concentration is derived. Formulae were also obtained to optimize the counting time in order to obtain the best precision in a minimum amount of time [fr

  16. Controlled Environment Specimen Transfer

    DEFF Research Database (Denmark)

    Damsgaard, Christian Danvad; Zandbergen, Henny W.; Hansen, Thomas Willum

    2014-01-01

    an environmental transmission electron microscope to an in situ X-ray diffractometer through a dedicated transmission electron microscope specimen transfer holder, capable of sealing the specimen in a gaseous environment at elevated temperatures. Two catalyst material systems have been investigated; Cu/ZnO/Al2O3...... transferred in a reactive environment to the environmental transmission electron microscope where further analysis on the local scale were conducted. The Co/Al2O3 catalyst was reduced in the environmental microscope and successfully kept reduced outside the microscope in a reactive environment. The in situ......Specimen transfer under controlled environment conditions, such as temperature, pressure, and gas composition, is necessary to conduct successive complementary in situ characterization of materials sensitive to ambient conditions. The in situ transfer concept is introduced by linking...

  17. A high-throughput mass spectrometry assay to simultaneously measure intact insulin and C-peptide.

    Science.gov (United States)

    Taylor, Steven W; Clarke, Nigel J; Chen, Zhaohui; McPhaul, Michael J

    2016-04-01

    Measurements of fasting levels of insulin and C-peptide are useful in documenting insulin resistance and may help predict development of diabetes mellitus. However, the specific insulin and C-peptide levels associated with specific degrees of insulin resistance have not been defined, owing to marked variability among immunoassays and lack of standardization. Herein, we describe a multiplexed liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay for intact insulin and C-peptide. Insulin and C-peptide were enriched from patient sera using monoclonal antibodies immobilized on magnetic beads and processed on a robotic liquid handler. Eluted peptides were analyzed by LC-MS/MS. Bovine insulin and a stable isotopically-labeled (13C/15N) C-peptide were utilized as internal standards. The assay had an analytical measurement range of 3 to 320 μIU/ml (18 to 1920 pmol/l) for insulin and 0.11 to 27.2 ng/ml (36 to 9006 pmol/l) for C-peptide. Intra- and inter-day assay variation was less than 11% for both peptides. Of the 5 insulin analogs commonly prescribed to treat diabetes, only the recombinant drug insulin lispro caused significant interference for the determination of endogenous insulin. There were no observed interferences for C-peptide. We developed and validated a high-throughput, quantitative, multiplexed LC-MS/MS assay for intact insulin and C-peptide. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Structured pathology reporting improves the macroscopic assessment of rectal tumour resection specimens.

    Science.gov (United States)

    King, Simon; Dimech, Margaret; Johnstone, Susan

    2016-06-01

    We examined whether introduction of a structured macroscopic reporting template for rectal tumour resection specimens improved the completeness and efficiency in collecting key macroscopic data elements. Fifty free text (narrative) macroscopic reports retrieved from 2012 to 2014 were compared with 50 structured macroscopic reports from 2013 to 2015, all of which were generated at John Hunter Hospital, Newcastle, NSW. The six standard macroscopic data elements examined in this study were reported in all 50 anatomical pathology reports using a structured macroscopic reporting dictation template. Free text reports demonstrated significantly impaired data collection when recording intactness of mesorectum (p<0.001), relationship to anterior peritoneal reflection (p=0.028) and distance of tumour to the non-peritonealised circumferential margin (p<0.001). The number of words used was also significantly (p<0.001) reduced using pre-formatted structured reports compared to free text reports. The introduction of a structured reporting dictation template improves data collection and may reduce the subsequent administrative burden when macroscopically evaluating rectal resections. Copyright © 2016 Royal College of Pathologists of Australasia. Published by Elsevier B.V. All rights reserved.

  19. Development of fatigue life evaluation method using small specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Wakai, Eichi; Tanigawa, Hiroyasu; Itoh, Takamoto; Hasegawa, Akira

    2013-01-01

    For developing the fatigue life evaluation method using small specimen, the effect of specimen size and shape on the fatigue life of the reduced activation ferritic/martensitic steels (F82H-IEA, F82H-BA07 and JLF-1) was investigated by the fatigue test at room temperature in air using round-bar and hourglass specimens with various specimen sizes (test section diameter: 0.85–10 mm). The round-bar specimen showed no specimen size and no specimen shape effects on the fatigue life, whereas the hourglass specimen showed no specimen size effect and obvious specimen shape effect on it. The shorter fatigue life of the hourglass specimen observed under low strain ranges could be attributed to the shorter micro-crack initiation life induced by the stress concentration dependent on the specimen shape. On the basis of this study, the small round-bar specimen was an acceptable candidate for evaluating the fatigue life using small specimen

  20. Total quantitative recording of elemental maps and spectra with a scanning microprobe

    International Nuclear Information System (INIS)

    Legge, G.J.F.; Hammond, I.

    1979-01-01

    A system of data recording and analysis has been developed by means of which simultaneously all data from a scanning instrument such as a microprobe can be quantitatively recorded and permanently stored, including spectral outputs from several detectors. Only one scanning operation is required on the specimen. Analysis is then performed on the stored data, which contain quantitative information on distributions of all elements and spectra of all regions

  1. Human thyroid specimen imaging by fluorescent x-ray computed tomography with synchrotron radiation

    Science.gov (United States)

    Takeda, Tohoru; Yu, Quanwen; Yashiro, Toru; Yuasa, Tetsuya; Hasegawa, Yasuo; Itai, Yuji; Akatsuka, Takao

    1999-09-01

    Fluorescent x-ray computed tomography (FXCT) is being developed to detect non-radioactive contrast materials in living specimens. The FXCT system consists of a silicon (111) channel cut monochromator, an x-ray slit and a collimator for fluorescent x ray detection, a scanning table for the target organ and an x-ray detector for fluorescent x-ray and transmission x-ray. To reduce Compton scattering overlapped on the fluorescent K(alpha) line, incident monochromatic x-ray was set at 37 keV. The FXCT clearly imaged a human thyroid gland and iodine content was estimated quantitatively. In a case of hyperthyroidism, the two-dimensional distribution of iodine content was not uniform, and thyroid cancer had a small amount of iodine. FXCT can be used to detect iodine within thyroid gland quantitatively and to delineate its distribution.

  2. Neural activation differences in amputees during imitation of intact versus amputee movements

    Directory of Open Access Journals (Sweden)

    William F Cusack

    2012-06-01

    Full Text Available The mirror neuron system has been attributed with increased activation in motor-related cortical areas upon viewing of another’s actions. Recent work suggests that limb movements that are similar and dissimilar in appearance to that of the viewer equivalently activate the mirror neuron system. It is unclear if this result can be observed in the action encoding areas in amputees who use prosthetic devices. Intact subjects and upper extremity amputee prosthesis users were recruited to view video demonstrations of tools being used by an intact actor and a prosthetic device user. All subjects were asked to pantomime the movements seen in the video while recording electroencephalography. Intact subjects showed equivalent left parietofrontal activity during imitation after watching the intact or prosthetic arm. Likewise, when prosthesis users imitated prosthesis demonstrations, typical left parietofrontal activation was observed during planning. When prosthesis users imitated intact actors, a new pattern was revealed which showed greater bilateral parietal and occipital activity during movement planning (p<0.001. This change may be required for prosthesis users to imitate movements in which the limb states between the observed and the observer do not match. The finding that prosthesis users imitating other prosthesis users showed typical left parietofrontal activation suggests that these subjects engage normal planning related activity when they are able to imitate a limb matching their own. This result has significant implications on rehabilitation, as standard therapy involves training with an intact occupational therapist, which could necessitate atypical planning mechanisms in amputees when learning to use their prosthesis.

  3. Specimen holder for an electron microscope and device and method for mounting a specimen in an electron microscope

    NARCIS (Netherlands)

    Zandbergen, H.W.; Latenstein van Voorst, A.; Westra, C.; Hoveling, G.H.

    1996-01-01

    A specimen holder for an electron microscope, comprising a bar-shaped body provided adjacent one end with means for receiving a specimen, with means being present for screening the specimen from the environment at least temporarily in airtight and moisture-proof manner in a first position, which

  4. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    Energy Technology Data Exchange (ETDEWEB)

    Soerensen, B.F.; Joergensen, K.; Oestergaard, R.C. [Risoe National Lab., Materials Dept., Roskilde (Denmark); Jacobsen, T.K. [LM Glasfiber A/S, Lunderskov (Denmark)

    2004-03-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratio between the two applied moments, the full mode mixity range from pure mode I to pure mode II can be generated for the same specimen geometry. The specimen allows stable crack growth. In case of large scale crack bridging, mixed mode cohesive laws can be obtained by a J integral based approach. As a preliminary example, fracture of adhesive joints between two glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre cross over bridging, eventually reaching a steady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement. Cohesive stresses were determined by a J integral approach. The deducted shear stress was found to be relative high ({approx} = 20 MPa) in comparison with the normal stress ({approx} = 1 MPa). (au)

  5. The Multilevel Mixed Intact Group Analysis: A Mixed Method to Seek, Detect, Describe and Explain Differences Between Intact Groups

    NARCIS (Netherlands)

    Schoonenboom, J.I.

    2014-01-01

    Educational innovations often involve intact subgroups, such as school classes or university departments. In small-scale educational evaluation research, typically involving 1 to 20 subgroups, differences among these subgroups are often neglected. This article presents a mixed method from a

  6. Progress towards in vitro quantitative imaging of human femur using compound quantitative ultrasonic tomography

    International Nuclear Information System (INIS)

    Lasaygues, Philippe; Ouedraogo, Edgard; Lefebvre, Jean-Pierre; Gindre, Marcel; Talmant, Marilyne; Laugier, Pascal

    2005-01-01

    The objective of this study is to make cross-sectional ultrasonic quantitative tomography of the diaphysis of long bones. Ultrasonic propagation in bones is affected by the severe mismatch between the acoustic properties of this biological solid and those of the surrounding soft medium, namely, the soft tissues in vivo or water in vitro. Bone imaging is then a nonlinear inverse-scattering problem. In this paper, we showed that in vitro quantitative images of sound velocities in a human femur cross section could be reconstructed by combining ultrasonic reflection tomography (URT), which provides images of the macroscopic structure of the bone, and ultrasonic transmission tomography (UTT), which provides quantitative images of the sound velocity. For the shape, we developed an image-processing tool to extract the external and internal boundaries and cortical thickness measurements. For velocity mapping, we used a wavelet analysis tool adapted to ultrasound, which allowed us to detect precisely the time of flight from the transmitted signals. A brief review of the ultrasonic tomography that we developed using correction algorithms of the wavepaths and compensation procedures are presented. Also shown are the first results of our analyses on models and specimens of long bone using our new iterative quantitative protocol

  7. Time-Dependent Changes in T1 during Fracture Healing in Juvenile Rats: A Quantitative MR Approach.

    Directory of Open Access Journals (Sweden)

    Katharina Baron

    Full Text Available Quantitative magnetic resonance imaging (qMRI offers several advantages in imaging and determination of soft tissue alterations when compared to qualitative imaging techniques. Although applications in brain and muscle tissues are well studied, its suitability to quantify relaxation times of intact and injured bone tissue, especially in children, is widely unknown. The objective observation of a fracture including its age determination can become of legal interest in cases of child abuse or maltreatment. Therefore, the aim of this study is the determination of time dependent changes in intact and corresponding injured bones in immature rats via qMRI, to provide the basis for an objective and radiation-free approach for fracture dating. Thirty-five MR scans of 7 Sprague-Dawley rats (male, 4 weeks old, 100 ± 5 g were acquired on a 3T MRI scanner (TimTrio, Siemens AG, Erlangen, Germany after the surgical infliction of an epiphyseal fracture in the tibia. The images were taken at days 1, 3, 7, 14, 28, 42 and 82 post-surgery. A proton density-weighted and a T1-weighted 3D FLASH sequence were acquired to calculate the longitudinal relaxation time T1 of the fractured region and the surrounding tissues. The calculation of T1 in intact and injured bone resulted in a quantitative observation of bone development in intact juvenile tibiae as well as the bone healing process in the injured tibiae. In both areas, T1 decreased over time. To evaluate the differences in T1 behaviour between the intact and injured bone, the relative T1 values (bone-fracture were calculated, showing clear detectable alterations of T1 after fracture occurrence. These results indicate that qMRI has a high potential not only for clinically relevant applications to detect growth defects or developmental alterations in juvenile bones, but also for forensically relevant applications such as the dating of fractures in cases of child abuse or maltreatment.

  8. Prospective comparison of the detection rates of human enterovirus and parechovirus RT-qPCR and viral culture in different pediatric specimens

    NARCIS (Netherlands)

    de Crom, S C M; Obihara, C C; de Moor, R A; Veldkamp, E J M; van Furth, A M; Rossen, J W A

    2013-01-01

    BACKGROUND: Reverse-transcriptase quantitative real-time polymerase chain reaction (RT-qPCR) has become the gold standard for the diagnosis of human enterovirus (EV) and parechovirus (HPeV) infections. The detection rate of RT-qPCR in different pediatric body specimens has not been compared

  9. Threats to intact tropical peatlands and opportunities for their conservation.

    Science.gov (United States)

    Roucoux, K H; Lawson, I T; Baker, T R; Del Castillo Torres, D; Draper, F C; Lähteenoja, O; Gilmore, M P; Honorio Coronado, E N; Kelly, T J; Mitchard, E T A; Vriesendorp, C F

    2017-12-01

    Large, intact areas of tropical peatland are highly threatened at a global scale by the expansion of commercial agriculture and other forms of economic development. Conserving peatlands on a landscape scale, with their hydrology intact, is of international conservation importance to preserve their distinctive biodiversity and ecosystem services and maintain their resilience to future environmental change. We explored threats to and opportunities for conserving remaining intact tropical peatlands; thus, we excluded peatlands of Indonesia and Malaysia, where extensive deforestation, drainage, and conversion to plantations means conservation in this region can protect only small fragments of the original ecosystem. We focused on a case study, the Pastaza-Marañón Foreland Basin (PMFB) in Peru, which is among the largest known intact tropical peatland landscapes in the world and is representative of peatland vulnerability. Maintenance of the hydrological conditions critical for carbon storage and ecosystem function of peatlands is, in the PMFB, primarily threatened by expansion of commercial agriculture linked to new transport infrastructure that is facilitating access to remote areas. There remain opportunities in the PMFB and elsewhere to develop alternative, more sustainable land-use practices. Although some of the peatlands in the PMFB fall within existing legally protected areas, this protection does not include the most carbon-dense (domed pole forest) areas. New carbon-based conservation instruments (e.g., REDD+, Green Climate Fund), developing markets for sustainable peatland products, transferring land title to local communities, and expanding protected areas offer pathways to increased protection for intact tropical peatlands in Amazonia and elsewhere, such as those in New Guinea and Central Africa which remain, for the moment, broadly beyond the frontier of commercial development. © 2017 The Authors. Conservation Biology published by Wiley Periodicals, Inc

  10. Epispadias in boys with an intact prepuce

    NARCIS (Netherlands)

    Bos, E. M. E.; Kuijper, C. F.; Chrzan, R. J.; Dik, P.; Klijn, A. J.; de Jong, T. P. V. M.

    2014-01-01

    To present an overview of the clinical presentation and pathological anatomy, and the results of surgical correction of 7 cases of epispadias with intact prepuce; a rare condition that has only occasionally been reported in literature. A retrospective search was performed in the surgical and

  11. HYDROCARBON VAPOR DIFFUSION IN INTACT CORE SLEEVES

    Science.gov (United States)

    The diffusion of 2,2,4-trimethylpentane (TMP) and 2,2,5-trimethylhexane (TMH) vapors put of residually contaminated sandy soil from the U.S. Environmental Protection Agency (EPA) field research site at Traverse City, Michigan, was measured and modeled. The headspace of an intact ...

  12. Improving ED specimen TAT using Lean Six Sigma.

    Science.gov (United States)

    Sanders, Janet H; Karr, Tedd

    2015-01-01

    Lean and Six Sigma are continuous improvement methodologies that have garnered international fame for improving manufacturing and service processes. Increasingly these methodologies are demonstrating their power to also improve healthcare processes. The purpose of this paper is to discuss a case study for the application of Lean and Six Sigma tools in the reduction of turnaround time (TAT) for Emergency Department (ED) specimens. This application of the scientific methodologies uncovered opportunities to improve the entire ED to lab system for the specimens. This case study provides details on the completion of a Lean Six Sigma project in a 1,000 bed tertiary care teaching hospital. Six Sigma's Define, Measure, Analyze, Improve, and Control methodology is very similar to good medical practice: first, relevant information is obtained and assembled; second, a careful and thorough diagnosis is completed; third, a treatment is proposed and implemented; and fourth, checks are made to determine if the treatment was effective. Lean's primary goal is to do more with less work and waste. The Lean methodology was used to identify and eliminate waste through rapid implementation of change. The initial focus of this project was the reduction of turn-around-times for ED specimens. However, the results led to better processes for both the internal and external customers of this and other processes. The project results included: a 50 percent decrease in vials used for testing, a 50 percent decrease in unused or extra specimens, a 90 percent decrease in ED specimens without orders, a 30 percent decrease in complete blood count analysis (CBCA) Median TAT, a 50 percent decrease in CBCA TAT Variation, a 10 percent decrease in Troponin TAT Variation, a 18.2 percent decrease in URPN TAT Variation, and a 2-5 minute decrease in ED registered nurses rainbow draw time. This case study demonstrated how the quantitative power of Six Sigma and the speed of Lean worked in harmony to improve

  13. Digested BLG can induce tolerance when co-administered with intact BLG in Brown Norway rats

    DEFF Research Database (Denmark)

    Bøgh, Katrine Lindholm; Barkholt, Vibeke; Madsen, Charlotte Bernhard

    the human gastro-duodenal digestion process. Four different fractions of BLG-digest was made, based on sizes of peptides or aggregates hereof. Intact BLG and the four fractions of BLG-digesta were characterized by protein chemical analyses. Brown Norway (BN) rats were immunised i.p. three times without......Background: Milk is a major constituent of small children’s diet. Milk allergy is also one of the most common allergies in small children. Prevention, treatment and general understanding of this allergy are therefore important. Methods: Intact BLG was digested in an in vitro model simulating...... the use of adjuvant with either PBS (control), 200 µg of intact BLG, 30 µg of intact BLG, 200 µg of digested BLG (with 30 µg of intact BLG), 200 µg of digested BLG, 200 µg of a fraction of large complexes or 200 µg of a fraction of small complexes (all three without intact BLG). Sera from BN rats were...

  14. A general mixed mode fracture mechanics test specimen: The DCB-specimen loaded with uneven bending moments

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jørgensen, K.; Jacobsen, T.K.

    2004-01-01

    A mixed mode specimen is proposed for fracture mechanics characterisation of adhesive joints, laminates and multilayers. The specimen is a double cantilever beam specimen loaded with uneven bending moments at the two free beams. By varying the ratiobetween the two applied moments, the full mode...... glass-fibre laminates was studied. The mixed mode fracture resistance increased with increasing crack length due to fibre bridging, eventually reaching asteady-state level (R-curve behaviour). The steady-state fracture toughness level increased with increasing tangential crack opening displacement....

  15. Comparative Tissue Proteomics of Microdissected Specimens Reveals Novel Candidate Biomarkers of Bladder Cancer*

    Science.gov (United States)

    Chen, Chien-Lun; Chung, Ting; Wu, Chih-Ching; Ng, Kwai-Fong; Yu, Jau-Song; Tsai, Cheng-Han; Chang, Yu-Sun; Liang, Ying; Tsui, Ke-Hung; Chen, Yi-Ting

    2015-01-01

    More than 380,000 new cases of bladder cancer are diagnosed worldwide, accounting for ∼150,200 deaths each year. To discover potential biomarkers of bladder cancer, we employed a strategy combining laser microdissection, isobaric tags for relative and absolute quantitation labeling, and liquid chromatography-tandem MS (LC-MS/MS) analysis to profile proteomic changes in fresh-frozen bladder tumor specimens. Cellular proteins from four pairs of surgically resected primary bladder cancer tumor and adjacent nontumorous tissue were extracted for use in two batches of isobaric tags for relative and absolute quantitation experiments, which identified a total of 3220 proteins. A DAVID (database for annotation, visualization and integrated discovery) analysis of dysregulated proteins revealed that the three top-ranking biological processes were extracellular matrix organization, extracellular structure organization, and oxidation-reduction. Biological processes including response to organic substances, response to metal ions, and response to inorganic substances were highlighted by up-expressed proteins in bladder cancer. Seven differentially expressed proteins were selected as potential bladder cancer biomarkers for further verification. Immunohistochemical analyses showed significantly elevated levels of three proteins—SLC3A2, STMN1, and TAGLN2—in tumor cells compared with noncancerous bladder epithelial cells, and suggested that TAGLN2 could be a useful tumor tissue marker for diagnosis (AUC = 0.999) and evaluating lymph node metastasis in bladder cancer patients. ELISA results revealed significantly increased urinary levels of both STMN1 and TAGLN2 in bladder cancer subgroups compared with control groups. In comparisons with age-matched hernia urine specimens, urinary TAGLN2 in bladder cancer samples showed the largest fold change (7.13-fold), with an area-under-the-curve value of 0.70 (p < 0.001, n = 205). Overall, TAGLN2 showed the most significant

  16. Recent advances in FIB-TEM specimen preparation techniques

    International Nuclear Information System (INIS)

    Li Jian; Malis, T.; Dionne, S.

    2006-01-01

    Preparing high-quality transmission electron microscopy (TEM) specimens is of paramount importance in TEM studies. The development of the focused ion beam (FIB) microscope has greatly enhanced TEM specimen preparation capabilities. In recent years, various FIB-TEM foil preparation techniques have been developed. However, the currently available techniques fail to produce TEM specimens from fragile and ultra-fine specimens such as fine fibers. In this paper, the conventional FIB-TEM specimen preparation techniques are reviewed, and their advantages and shortcomings are compared. In addition, a new technique suitable to prepare TEM samples from ultra-fine specimens is demonstrated

  17. Reliability of 46,XX results on miscarriage specimens: a review of 1,222 first-trimester miscarriage specimens.

    Science.gov (United States)

    Lathi, Ruth B; Gustin, Stephanie L F; Keller, Jennifer; Maisenbacher, Melissa K; Sigurjonsson, Styrmir; Tao, Rosina; Demko, Zach

    2014-01-01

    To examine the rate of maternal contamination in miscarriage specimens. Retrospective review of 1,222 miscarriage specimens submitted for chromosome testing with detection of maternal cell contamination (MCC). Referral centers requesting genetic testing of miscarriage specimens at a single reference laboratory. Women with pregnancy loss who desire complete chromosome analysis of the pregnancy tissue. Analysis of miscarriage specimens using single-nucleotide polymorphism (SNP) microarray technology with bioinformatics program to detect maternal cell contamination. Chromosome content of miscarriages and incidence of 46,XX results due to MCC. Of the 1,222 samples analyzed, 592 had numeric chromosomal abnormalities, and 630 were normal 46,XX or 46,XY (456 and 187, respectively). In 269 of the 46,XX specimens, MCC with no embryonic component was found. With the exclusion of maternal 46,XX results, the chromosomal abnormality rate increased from 48% to 62%, and the ratio for XX to XY results dropped from 2.6 to 1.0. Over half of the normal 46,XX results in miscarriage specimens were due to MCC. The use of SNPs in MCC testing allows for precise identification of chromosomal abnormalities in miscarriage as well as MCC, improving the accuracy of products of conception testing. Copyright © 2014 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  18. Immunohistochemical Markers for Quantitative Studies of Neurons and Glia in Human Neocortex

    DEFF Research Database (Denmark)

    Lyck, Lise; Dalmau, Ishar; Chemnitz, John

    2007-01-01

    Reproducible visualisation of neurons and glia in human brain is essential for quantitative studies of the cellular changes in neurological disease. However, immunohistochemistry in human brain specimens is often compromised due to prolonged fixation. To select cell-lineage specific antibodies fo...

  19. Intacting Integrity in coping with health issues

    DEFF Research Database (Denmark)

    Jepsen, Stine Leegaard; Bastrup Jørgensen, Lene; Fridlund, Bengt

    2017-01-01

    The aim of this study was to develop a formal substantive theory (FST) on the multidimensional behavioral process of coping with health issues. Intacting integrity while coping with health issues emerged as the core category of this FST. People facing health issues strive to safeguard and keep...

  20. Development of fatigue life evaluation technique using miniature specimen

    International Nuclear Information System (INIS)

    Nogami, Shuhei; Nishimura, Arata; Fujiwara, Masaharu; Hisaka, Tomoaki

    2012-01-01

    To develop the fatigue life evaluation technique using miniature specimen, the investigation of the effect of specimen size and specimen shape on the fatigue life and the development of the fatigue testing machine, especially the extensometer, were carried out. The effect of specimen size on the fatigue life was almost negligible for the round-bar specimens. The shorter fatigue life at relatively low strain range conditions for the hourglass specimen that the standard specimen were observed. Therefore the miniature round-bar specimen was considered to be adequate for the fatigue life evaluation using small specimen. Several types of the extensometer system using a strain gauge and a laser has been developed for realizing the fatigue test of the miniature round-bar specimen at high temperature in vacuum. (author)

  1. Visual speech alters the discrimination and identification of non-intact auditory speech in children with hearing loss.

    Science.gov (United States)

    Jerger, Susan; Damian, Markus F; McAlpine, Rachel P; Abdi, Hervé

    2017-03-01

    Understanding spoken language is an audiovisual event that depends critically on the ability to discriminate and identify phonemes yet we have little evidence about the role of early auditory experience and visual speech on the development of these fundamental perceptual skills. Objectives of this research were to determine 1) how visual speech influences phoneme discrimination and identification; 2) whether visual speech influences these two processes in a like manner, such that discrimination predicts identification; and 3) how the degree of hearing loss affects this relationship. Such evidence is crucial for developing effective intervention strategies to mitigate the effects of hearing loss on language development. Participants were 58 children with early-onset sensorineural hearing loss (CHL, 53% girls, M = 9;4 yrs) and 58 children with normal hearing (CNH, 53% girls, M = 9;4 yrs). Test items were consonant-vowel (CV) syllables and nonwords with intact visual speech coupled to non-intact auditory speech (excised onsets) as, for example, an intact consonant/rhyme in the visual track (Baa or Baz) coupled to non-intact onset/rhyme in the auditory track (/-B/aa or/-B/az). The items started with an easy-to-speechread/B/or difficult-to-speechread/G/onset and were presented in the auditory (static face) vs. audiovisual (dynamic face) modes. We assessed discrimination for intact vs. non-intact different pairs (e.g., Baa:/-B/aa). We predicted that visual speech would cause the non-intact onset to be perceived as intact and would therefore generate more same-as opposed to different-responses in the audiovisual than auditory mode. We assessed identification by repetition of nonwords with non-intact onsets (e.g.,/-B/az). We predicted that visual speech would cause the non-intact onset to be perceived as intact and would therefore generate more Baz-as opposed to az- responses in the audiovisual than auditory mode. Performance in the audiovisual mode showed more same

  2. Visual Speech Alters the Discrimination and Identification of Non-Intact Auditory Speech in Children with Hearing Loss

    Science.gov (United States)

    Jerger, Susan; Damian, Markus F.; McAlpine, Rachel P.; Abdi, Hervé

    2017-01-01

    Objectives Understanding spoken language is an audiovisual event that depends critically on the ability to discriminate and identify phonemes yet we have little evidence about the role of early auditory experience and visual speech on the development of these fundamental perceptual skills. Objectives of this research were to determine 1) how visual speech influences phoneme discrimination and identification; 2) whether visual speech influences these two processes in a like manner, such that discrimination predicts identification; and 3) how the degree of hearing loss affects this relationship. Such evidence is crucial for developing effective intervention strategies to mitigate the effects of hearing loss on language development. Methods Participants were 58 children with early-onset sensorineural hearing loss (CHL, 53% girls, M = 9;4 yrs) and 58 children with normal hearing (CNH, 53% girls, M = 9;4 yrs). Test items were consonant-vowel (CV) syllables and nonwords with intact visual speech coupled to non-intact auditory speech (excised onsets) as, for example, an intact consonant/rhyme in the visual track (Baa or Baz) coupled to non-intact onset/rhyme in the auditory track (/–B/aa or /–B/az). The items started with an easy-to-speechread /B/ or difficult-to-speechread /G/ onset and were presented in the auditory (static face) vs. audiovisual (dynamic face) modes. We assessed discrimination for intact vs. non-intact different pairs (e.g., Baa:/–B/aa). We predicted that visual speech would cause the non-intact onset to be perceived as intact and would therefore generate more same—as opposed to different—responses in the audiovisual than auditory mode. We assessed identification by repetition of nonwords with non-intact onsets (e.g., /–B/az). We predicted that visual speech would cause the non-intact onset to be perceived as intact and would therefore generate more Baz—as opposed to az— responses in the audiovisual than auditory mode. Results

  3. Design of specimen for weld residual stress simulation

    International Nuclear Information System (INIS)

    Kim, Jin Weon; Park, Jong Sun; Lee, Kyung Soo

    2008-01-01

    The objective of this study is to design a laboratory specimen for simulating residual stress of circumferential butt welding of pipe. Specimen type and method for residual stress generation were proposed based on the review of prior studies and parametric finite element simulation. To prove the proposed specimen type and loading method, the residual stress was generated using the designed specimen by applying proposed method and was measured. The measured residual stress using X-ray diffraction reasonably agreed with the results of finite element simulation considered in the specimen design. Comparison of residual strains measured at several locations of specimen and given by finite element simulation also showed good agreement. Therefore, it is indicated that the designed specimen can reasonably simulate the residual stress of circumferential butt welding of pipe

  4. Performance of intact and castrated beef cattle in an intensive croppasture rotation system

    Directory of Open Access Journals (Sweden)

    Tercilio Turini

    2015-07-01

    Full Text Available This research had as objective to evaluate the performance of intact or castrated beef cattle in a croppasture rotation system. The experiment was conducted during 2004 and 2005, and carried out at the Cooperativa Agropecuária Mourãoense (COAMO Experimental Farm, in Campo Mourão city, Paraná state. It was used a completely randomized design, with two treatments, intact or castrated. Forty ½Angus+½Nelore crossbred animals, with average age of nine months, were used. Half of the animals were castrated at weaning, and the other half was kept intact. Pasture was composed of two areas. The winter field, established after soybean crop, was composed by a mixture of black oat (Avena strigosa and Italian ryegrass (Lolium multiforum. The summer field was composed by stargrass (Cynodon nlemfuensis and Mombaça grass (Panicum maximum. During the winter time it was used a continues grazing system, with regulator animals (put and take, and during the summer an intensive rotational system, with regulator animals and fixed grazing period. Intact animals presented higher average daily weight gain (0.907 vs 0.698 kg, slaughter weight (490.9 vs 442.2 kg, and hot carcass weight (250.2 vs 232.6 kg. Slaughter age was influenced by sexual condition, being lesser in the intact animals. Carcass dressing percentage was similar for the groups. Castrated animals showed better finishing fat cover and backfat thickness (3.45 vs 2.70 mm compared to intact ones. Therefore, it can be concluded that intact animals presents better performance than castrated ones when finished in an intensive crop-pasture rotation system, however, they may not present the minimum required fat cover, when slaughter at young ages.

  5. TEM specimen preparation of semiconductor-PMMA-metal interfaces

    International Nuclear Information System (INIS)

    Thangadurai, P.; Lumelsky, Yulia; Silverstein, Michael S.; Kaplan, Wayne D.

    2008-01-01

    Transmission electron microscopy (TEM) cross-section specimens of PMMA in contact with gold and Si were prepared by focused ion beam (FIB) and compared with plan-view PMMA specimens prepared by a dip-coating technique. The specimens were characterized by TEM and electron energy loss spectroscopy (EELS). In the cross-section specimens, the thin films of PMMA were located in a Si-PMMA-Au multilayer. Different thicknesses of PMMA films were spin-coated on the Si substrates. The thickness of the TEM specimens prepared by FIB was estimated using EELS to be 0.65 of the plasmon mean-free-path. Along the PMMA-Au interface, Au particle diffusion into the PMMA was observed, and the size of the Au particles was in the range of 2-4 nm. Dip-coating of PMMA directly on Cu TEM grids resulted in thin specimens with a granular morphology, with a thickness of 0.58 of the plasmon mean-free-path. The dip-coated specimens were free from ion milling induced artifacts, and thus serve as control specimens for comparison with the cross-sectioned specimens prepared by FIB

  6. Quantitative magnetic-moment mapping of a permanent-magnet material by X-ray magnetic circular dichroism nano-spectroscopy

    Directory of Open Access Journals (Sweden)

    Tetsuro Ueno

    2017-05-01

    Full Text Available We demonstrate the quantitative mapping of magnetic moments in a permanent-magnet material by X-ray magnetic circular dichroism nano-spectroscopy. An SmCo5 specimen was prepared from the bulk material by using a micro-fabrication technique. Scanning transmission X-ray microscopy images were obtained around the Sm M4,5 absorption edges. By applying the magneto-optical sum rules to these images, we obtained quantitative maps of the orbital and spin magnetic moments as well as their ratio. We found that the magnitudes of the orbital and spin magnetic moments and their ratio do not depend on thickness of the specimen.

  7. Cholesteatoma behind an intact tympanic membrane: histopathologic evidence for a tympanic membrane origin.

    Science.gov (United States)

    Sudhoff, H; Linthicum, F H

    2001-07-01

    Several theories have been proposed with respect to the origin and pathogenesis of cholesteatoma behind an intact tympanic membrane. The authors describe a case of cholesteatoma behind an intact tympanic membrane in a 71-year-old man with a history of tympanic membrane retraction fixed to the incus without evidence of a perforation. The membrane eventually became detached, and remnants of keratinizing squamous epithelium were found on the incus. Mechanisms such as metaplasia, ectopic epidermis rests, or ingrowth of meatal epidermis have been proposed to explain the pathogenesis of cholesteatoma behind an intact tympanic membrane. These findings, based on temporal bone histopathology, support the role of an acquired epidermal rest. This case report provides evidence that cholesteatoma behind an intact tympanic membrane can be established from a resolved retraction of the pars tensa of the tympanic membrane.

  8. The Multilevel Mixed Intact Group Analysis: A Mixed Method to Seek, Detect, Describe, and Explain Differences Among Intact Groups

    Science.gov (United States)

    Schoonenboom, Judith

    2016-01-01

    Educational innovations often involve intact subgroups, such as school classes or university departments. In small-scale educational evaluation research, typically involving 1 to 20 subgroups, differences among these subgroups are often neglected. This article presents a mixed method from a qualitative perspective, in which differences among…

  9. Structural determination of intact proteins using mass spectrometry

    Science.gov (United States)

    Kruppa, Gary [San Francisco, CA; Schoeniger, Joseph S [Oakland, CA; Young, Malin M [Livermore, CA

    2008-05-06

    The present invention relates to novel methods of determining the sequence and structure of proteins. Specifically, the present invention allows for the analysis of intact proteins within a mass spectrometer. Therefore, preparatory separations need not be performed prior to introducing a protein sample into the mass spectrometer. Also disclosed herein are new instrumental developments for enhancing the signal from the desired modified proteins, methods for producing controlled protein fragments in the mass spectrometer, eliminating complex microseparations, and protein preparatory chemical steps necessary for cross-linking based protein structure determination.Additionally, the preferred method of the present invention involves the determination of protein structures utilizing a top-down analysis of protein structures to search for covalent modifications. In the preferred method, intact proteins are ionized and fragmented within the mass spectrometer.

  10. Comparison of gross anatomy test scores using traditional specimens vs. QuickTime Virtual Reality animated specimens

    Science.gov (United States)

    Maza, Paul Sadiri

    In recent years, technological advances such as computers have been employed in teaching gross anatomy at all levels of education, even in professional schools such as medical and veterinary medical colleges. Benefits of computer based instructional tools for gross anatomy include the convenience of not having to physically view or dissect a cadaver. Anatomy educators debate over the advantages versus the disadvantages of computer based resources for gross anatomy instruction. Many studies, case reports, and editorials argue for the increased use of computer based anatomy educational tools, while others discuss the necessity of dissection for various reasons important in learning anatomy, such as a three-dimensional physical view of the specimen, physical handling of tissues, interactions with fellow students during dissection, and differences between specific specimens. While many articles deal with gross anatomy education using computers, there seems to be a lack of studies investigating the use of computer based resources as an assessment tool for gross anatomy, specifically using the Apple application QuickTime Virtual Reality (QTVR). This study investigated the use of QTVR movie modules to assess if using computer based QTVR movie module assessments were equal in quality to actual physical specimen examinations. A gross anatomy course in the College of Veterinary Medicine at Cornell University was used as a source of anatomy students and gross anatomy examinations. Two groups were compared, one group taking gross anatomy examinations in a traditional manner, by viewing actual physical specimens and answering questions based on those specimens. The other group took the same examinations using the same specimens, but the specimens were viewed as simulated three-dimensional objects in a QTVR movie module. Sample group means for the assessments were compared. A survey was also administered asking students' perceptions of quality and user-friendliness of the QTVR

  11. Evaluation of irradiated coating material specimens

    International Nuclear Information System (INIS)

    Lee, Yong Jin; Nam, Seok Woo; Cho, Lee Moon

    2007-12-01

    Evaluation result of irradiated coating material specimens - Coating material specimens radiated Gamma Energy(Co 60) in air condition. - Evaluation conditions was above 1 X 10 4 Gy/hr, and radiated TID 2.0 X 10 6 Gy. - The radiated coating material specimens, No Checking, Cracking, Flaking, Delamination, Peeling and Blistering. - Coating system at the Kori no. 1 and APR 1400 Nuclear power plant, evaluation of irradiated coating materials is in accordance with owner's requirement(2.0 X 10 6 Gy)

  12. How can we conserve intact tropical peatlands?

    Science.gov (United States)

    Lawson, Ian; Roucoux, Katherine

    2017-04-01

    The scientific community has, for more than three decades, been expressing increasing alarm about the fate of peatlands in parts of Indonesia and Malaysia, where extensive land-use conversion and drainage for rice and oil palm have greatly compromised peatland hydrology, ecology, biological richness, and carbon storage. The discourse in the literature on these peatlands is now moving on from attempts to preserve the last remaining fragments of peat-swamp forest, towards discussion of how best to restore damaged ecosystems, and whether it is possible to manage plantations more 'sustainably'. It is becoming increasingly clear, however, that peatlands occur quite widely in other parts of the lowland tropics, including parts of Amazonia and the Congo Basin, and many of these peatlands can reasonably be described as 'intact': although few if any parts of the tropics are totally unaffected by human actions, the hydrology and functional ecology of these systems appear to be close to a 'natural' state. The question then arises as to what should be done with the knowledge of their existence. Here we analyse the arguments in favour of protecting intact peatlands, and the potential conflicts with other priorities such as economic development and social justice. We evaluate alternative mechanisms for protecting intact peatlands, focusing on the particular issues raised by peatlands as opposed to other kinds of tropical ecosystem. We identify ways in which natural science agendas can help to inform these arguments, using our own contributions in palaeoecology and carbon mapping as examples. Finally, we argue for a radical reconsideration of research agendas in tropical peatlands, highlighting the potential contribution of methodologies borrowed from the social sciences and humanities.

  13. Evaluation of conventional, dynamic contrast enhanced and diffusion weighted MRI for quantitative Crohn's disease assessment with histopathology of surgical specimens

    NARCIS (Netherlands)

    Tielbeek, Jeroen A. W.; Ziech, Manon L. W.; Li, Zhang; Lavini, Cristina; Bipat, Shandra; Bemelman, Willem A.; Roelofs, Joris J. T. H.; Ponsioen, Cyriel Y.; Vos, Frans M.; Stoker, Jaap

    2014-01-01

    To prospectively compare conventional MRI sequences, dynamic contrast enhanced (DCE) MRI and diffusion weighted imaging (DWI) with histopathology of surgical specimens in Crohn's disease. 3-T MR enterography was performed in consecutive Crohn's disease patients scheduled for surgery within 4 weeks.

  14. Measurements and Counts for Notacanthidae Specimens

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Taxonomic data were collected for specimens of deep-sea spiny eels (Notacanthidae) from the Hawaiian Ridge by Bruce C. Mundy. Specimens were collected off the north...

  15. 3-D visualization and quantitation of microvessels in transparent human colorectal carcinoma [corrected].

    Directory of Open Access Journals (Sweden)

    Yuan-An Liu

    Full Text Available Microscopic analysis of tumor vasculature plays an important role in understanding the progression and malignancy of colorectal carcinoma. However, due to the geometry of blood vessels and their connections, standard microtome-based histology is limited in providing the spatial information of the vascular network with a 3-dimensional (3-D continuum. To facilitate 3-D tissue analysis, we prepared transparent human colorectal biopsies by optical clearing for in-depth confocal microscopy with CD34 immunohistochemistry. Full-depth colons were obtained from colectomies performed for colorectal carcinoma. Specimens were prepared away from (control and at the tumor site. Taking advantage of the transparent specimens, we acquired anatomic information up to 200 μm in depth for qualitative and quantitative analyses of the vasculature. Examples are given to illustrate: (1 the association between the tumor microstructure and vasculature in space, including the perivascular cuffs of tumor outgrowth, and (2 the difference between the 2-D and 3-D quantitation of microvessels. We also demonstrate that the optically cleared mucosa can be retrieved after 3-D microscopy to perform the standard microtome-based histology (H&E staining and immunohistochemistry for systematic integration of the two tissue imaging methods. Overall, we established a new tumor histological approach to integrate 3-D imaging, illustration, and quantitation of human colonic microvessels in normal and cancerous specimens. This approach has significant promise to work with the standard histology to better characterize the tumor microenvironment in colorectal carcinoma.

  16. Notch effects in uniaxial tension specimens

    International Nuclear Information System (INIS)

    Delph, T.J.

    1979-03-01

    Results of a literature survey on the effect of notches on the time-dependent failure of uniaxial tension specimens at elevated temperatures are presented. Particular attention is paid to the failure of notched specimens containing weldments

  17. Reflective type objective based spectral-domain phase-sensitive optical coherence tomography for high-sensitive structural and functional imaging of cochlear microstructures through intact bone of an excised guinea pig cochlea

    Science.gov (United States)

    Subhash, Hrebesh M.; Wang, Ruikang K.; Chen, Fangyi; Nuttall, Alfred L.

    2013-03-01

    Most of the optical coherence tomographic (OCT) systems for high resolution imaging of biological specimens are based on refractive type microscope objectives, which are optimized for specific wave length of the optical source. In this study, we present the feasibility of using commercially available reflective type objective for high sensitive and high resolution structural and functional imaging of cochlear microstructures of an excised guinea pig through intact temporal bone. Unlike conventional refractive type microscopic objective, reflective objective are free from chromatic aberrations due to their all-reflecting nature and can support a broadband of spectrum with very high light collection efficiency.

  18. Technique of manufacturing specimen of irradiated fuel rods

    International Nuclear Information System (INIS)

    Min, Duck Seok; Seo, Hang Seok; Min, Duck Kee; Koo, Dae Seo; Lee, Eun Pyo; Yang, Song Yeol

    1999-04-01

    Technique of manufacturing specimen of irradiated fuel rods to perform efficient PIE is developed by analyzing the relation between requiring time of manufacturing specimen and manufacturing method in irradiated fuel rods. It takes within an hour to grind 1 mm of specimen thickness under 150 rpm in speed of grinding, 600 g gravity in force using no.120, no.240, no.320 of grinding paper. In case of no.400 of grinding paper, it takes more an hour to grind the same thickness as above. It takes up to a quarter to grind 80-130 μm in specimen thickness using no.400 of grinding paper. When grinding time goes beyond 15 minutes, the grinding thickness of specimen does not exist. The polishing of specimen with 150 Rpms in speed of grinding machine, 600 g gravity in force, 10 minutes in polishing time using diamond paste 15 μm on polishing cloths amounts to 50 μm in specimen thickness. In case of diamond paste 9 μm on polishing cloth, the polishing of specimen amounts to 20 μm. The polishing thickness of specimen with 15 minutes in polishing time using 6 μm, 3 μm, 1 μm, 1/4 μm does not exist. Technique of manufacturing specimen of irradiated fuel rods will have application to the destructive examination of PIE. (author). 6 refs., 1 tab., 10 figs

  19. (Photosynthesis in intact plants)

    Energy Technology Data Exchange (ETDEWEB)

    1990-01-01

    Progress in the two years since the last renewal application has been excellent. We have made substantial contributions on both main fronts of the projects, and are particularly happy with the progress of our research on intact plants. The approach of basing our field work on a sound foundation of laboratory studies has enabled is to use methods which provide unambiguous assays of well characterized reactions. We have also made excellent progress in several laboratory studies which will have direct applications in future field work, and have introduced to the laboratory a range of molecular genetics techniques which will allow us to explore new options in the attempt to understand function at the level of molecular structure.

  20. Specimen loading list for the varying temperature experiment

    International Nuclear Information System (INIS)

    Qualls, A.L.; Sitterson, R.G.

    1998-01-01

    The varying temperature experiment HFIR-RB-13J has been assembled and inserted in the reactor. Approximately 5300 specimens were cleaned, inspected, matched, and loaded into four specimen holders. A listing of each specimen loaded into the steady temperature holder, its position in the capsule, and the identification of the corresponding specimen loaded into the varying temperature holder is presented in this report

  1. Recent advances on Charpy specimen reconstitution techniques

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J., E-mail: aandrade@ipen.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-07-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  2. Recent advances on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Andrade, Arnaldo H.P.; Lobo, Raquel M.; Miranda, Carlos Alexandre J.

    2017-01-01

    Charpy specimen reconstitution is widely used around the world as a tool to enhance or supplement surveillance programs of nuclear reactor pressure vessels. The reconstitution technique consists in the incorporation of a small piece from a previously tested specimen into a compound specimen, allowing to increase the number of tests. This is especially important if the available materials is restricted and fracture mechanics parameter have to be determined. The reconstitution technique must fulfill some demands, among them tests results like the original standard specimens and the loaded material of the insert must not be influenced by the welding and machining procedure. It is known that reconstitution of Charpy specimens may affect the impact energy in a consequence of the constraint of plastic deformation by the hardened weldment and HAZ. This paper reviews some recent advances of the reconstitution technique and its applications. (author)

  3. Does human leukocyte elastase degrade intact skin elastin?

    DEFF Research Database (Denmark)

    Schmelzer, Christian E H; Jung, Michael C; Wohlrab, Johannes

    2012-01-01

    This study aimed to investigate the susceptibility of intact fibrillar human elastin to human leukocyte elastase and cathepsin G. Elastin is a vital protein of the extracellular matrix of vertebrates, and provides exceptional properties including elasticity and tensile strength to many tissues...... and organs, including the aorta, lung, cartilage, elastic ligaments and skin, and is thus critical for their long-term function. Mature elastin is an insoluble and extremely durable protein that undergoes very little turnover, but sustained exposure to proteases may lead to irreversible and severe damage......, and thus to functional loss of the elastic fiber network. Hence, it is a key issue to understand which enzymes actually initiate elastolysis under certain pathological conditions or during intrinsic aging. In this paper, we provide a complete workflow for isolation of pure and intact elastin from very...

  4. DNA synthesis in periportal and perivenous hepatocytes of intact and hepatectomized young mice.

    Science.gov (United States)

    Fernández-Blanco, A; Inda, A M; Errecalde, A L

    2015-01-01

    DNA synthesis of hepatocytes in two areas of Intact and Hepatectomized young mice liver along a circadian period was studied. DNA synthesis was significantly different at all analyzed time points in Intact and Hepatectomized animals. Differences between periportal and perivenous hepatocytes were found in hepatectomized animals at 04/42 and 08/46 hr of day/hour post-hepatectomy. DNAs peak in periportal hepatocytes regenerating liver occurs 4 hr earlier than in perivenous hepatocytes, probably reflecting their shorter G1 phase. Besides, daily mean values of regenerating livers were higher than those observed in Intact animals, as a consequence of surgical removal.

  5. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Science.gov (United States)

    Demšar, Ivan; Duhovnik, Jože; Lešnik, Blaž; Supej, Matej

    2015-01-01

    The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW), various skiing regimes were simulated. Change of Flexion Angle (CoFA) and Range of Motion (RoM) in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1°) was significantly lower compared to an intact leg (5.9 ± 1.8°) and the control group (6.5 ± 2.3°). In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2°) was significantly larger than that of the intact leg (34.7 ± 4.4°). The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing. Key points The RoM in the ski boot on the side of the prosthetic leg was smaller than the RoM of the intact leg and the control group of healthy subjects. The RoM in the ankle joint of prosthetic leg was comparable to that of the intact leg and the control group of healthy subjects. The RoM in the prosthetic knee joint was greater than the RoM in the knee joint of the

  6. Antimicrobial activity of a new intact skin antisepsis formulation.

    Science.gov (United States)

    Russo, Antonello; Viotti, Pier Luigi; Vitali, Matteo; Clementi, Massimo

    2003-04-01

    Different antiseptic formulations have shown limitations when applied to disinfecting intact skin, notably short-term tolerability and/or efficacy. The purpose of this study was optimizing a new antiseptic formulation specifically targeted at intact skin disinfection and evaluating its in vitro microbicidal activity and in vivo efficacy. The biocidal properties of the antiseptic solution containing 0.5% chloramine-T diluted in 50% isopropyl alcohol (Cloral; Eurospital SpA Trieste, Italy) were measured in vitro versus gram-positive-, gram-negative-, and acid-alcohol-resistant germs and fungi with standard suspension tests in the presence of fetal bovine serum. Virus-inhibiting activity was evaluated in vitro against human cytomegalovirus, herpes simplex virus, poliovirus, hepatitis B virus, and hepatitis C virus. Tests used different methods for the different biologic and in vitro replication capacity of these human viruses. Lastly, Cloral tolerability and skin colonization retardation efficacy after disinfection were studied in vivo. The antiseptic under review showed fast and sustained antimicrobial activity. The efficacy of Cloral against clinically important bacterial and viral pathogens and fungi was highlighted under the experimental conditions described in this article. Finally, microbial regrowth lag and no side effects were documented in vivo after disinfection of 11 volunteers. A stable chloramine-T solution in isopropyl alcohol may be suggested for intact skin antisepsis.

  7. Investigation of Mitochondrial Dysfunction by Sequential Microplate-Based Respiration Measurements from Intact and Permeabilized Neurons

    Science.gov (United States)

    Clerc, Pascaline; Polster, Brian M.

    2012-01-01

    Mitochondrial dysfunction is a component of many neurodegenerative conditions. Measurement of oxygen consumption from intact neurons enables evaluation of mitochondrial bioenergetics under conditions that are more physiologically realistic compared to isolated mitochondria. However, mechanistic analysis of mitochondrial function in cells is complicated by changing energy demands and lack of substrate control. Here we describe a technique for sequentially measuring respiration from intact and saponin-permeabilized cortical neurons on single microplates. This technique allows control of substrates to individual electron transport chain complexes following permeabilization, as well as side-by-side comparisons to intact cells. To illustrate the utility of the technique, we demonstrate that inhibition of respiration by the drug KB-R7943 in intact neurons is relieved by delivery of the complex II substrate succinate, but not by complex I substrates, via acute saponin permeabilization. In contrast, methyl succinate, a putative cell permeable complex II substrate, failed to rescue respiration in intact neurons and was a poor complex II substrate in permeabilized cells. Sequential measurements of intact and permeabilized cell respiration should be particularly useful for evaluating indirect mitochondrial toxicity due to drugs or cellular signaling events which cannot be readily studied using isolated mitochondria. PMID:22496810

  8. Gram staining of protected pulmonary specimens in the early diagnosis of ventilator-associated pneumonia.

    Science.gov (United States)

    Mimoz, O; Karim, A; Mazoit, J X; Edouard, A; Leprince, S; Nordmann, P

    2000-11-01

    We evaluated prospectively the use of Gram staining of protected pulmonary specimens to allow the early diagnosis of ventilator-associated pneumonia (VAP), compared with the use of 60 bronchoscopic protected specimen brushes (PSB) and 126 blinded plugged telescopic catheters (PTC) obtained from 134 patients. Gram stains were from Cytospin slides; they were studied for the presence of microorganisms in 10 and 50 fields by two independent observers and classified according to their Gram stain morphology. Quantitative cultures were performed after serial dilution and plating on appropriate culture medium. A final diagnosis of VAP, based on a culture of > or = 10(3) c.f.u. ml-1, was established after 81 (44%) samplings. When 10 fields were analysed, a strong relationship was found between the presence of bacteria on Gram staining and the final diagnosis of VAP (for PSB and PTC respectively: sensitivity 74 and 81%, specificity 94 and 100%, positive predictive value 91 and 100%, negative predictive value 82 and 88%). The correlation was less when we compared the morphology of microorganisms observed on Gram staining with those of bacteria obtained from quantitative cultures (for PSB and PTC respectively: sensitivity 54 and 69%, specificity 86 and 89%, positive predictive value 72 and 78%, negative predictive value 74 and 84%). Increasing the number of fields read to 50 was associated with a slight decrease in specificity and positive predictive value of Gram staining, but with a small increase in its sensitivity and negative predictive value. The results obtained by the two observers were similar to each other for both numbers of fields analysed. Gram staining of protected pulmonary specimens performed on 10 fields predicted the presence of VAP and partially identified (using Gram stain morphology) the microorganisms growing at significant concentrations, and could help in the early choice of the treatment of VAP. Increasing the number of fields read or having the Gram

  9. Impulse radar scanning of intact salt at the Avery Island Mine

    International Nuclear Information System (INIS)

    Cook, C.W.

    1980-05-01

    A series of experiments was run in the Avery Island Mine to evaluate the capability of an impulse radar to locate anomalies and simulated waste targets in intact dome salt. Voids in salt were difficult to detect. On the positive side, metal targets and simulated waste (glass) were easily located in intact salt. Radar scanning at ranges of greater than 25 meters and short-range resolution of target positions to within a few centimeters were achieved

  10. Performance of intact and partially degraded concrete barriers in limiting fluid flow

    International Nuclear Information System (INIS)

    Walton, J.C.; Seitz, R.R.

    1991-07-01

    Concrete barriers will play a critical role in the long-term isolation of low-level radioactive wastes. Over time the barriers will degrade, and in many cases, the fundamental processes controlling performance of the barriers will be different for intact and degraded conditions. This document examines factors controlling fluid flow through intact and degraded concrete disposal facilities. Simplified models are presented fro predicting build up of fluid above a vault; fluid flow through and around intact vaults, through flaws in coatings/liners applied to a vault, and through cracks in a concrete vault; and the influence of different backfill materials around the outside of the vault. Example calculations are presented to illustrate the parameters and processes that influence fluid flow. 46 refs., 49 figs., 2 tabs

  11. Bioavailability and in vivo metabolism of intact glucosinolates

    DEFF Research Database (Denmark)

    Sørensen, Jens Christian; Frandsen, Heidi Blok; Jensen, Søren Krogh

    2016-01-01

    Health benefits associated with consumption of cruciferous vegetables have received considerable attention with a hitherto focus on the role and bioactivity of glucosinolate degradation products. We investigated the in vivo metabolism of intact glucosinolates by following their fate in digesta an...

  12. Biomechanical Effect of Margin Convergence Techniques: Quantitative Assessment of Supraspinatus Muscle Stiffness.

    Directory of Open Access Journals (Sweden)

    Taku Hatta

    Full Text Available Although the margin convergence (MC technique has been recognized as an option for rotator cuff repair, little is known about the biomechanical effect on repaired rotator cuff muscle, especially after supplemented footprint repair. The purpose of this study was to assess the passive stiffness changes of the supraspinatus (SSP muscle after MC techniques using shear wave elastography (SWE. A 30 × 40-mm U-shaped rotator cuff tear was created in 8 cadaveric shoulders. Each specimen was repaired with 6 types of MC technique (1-, 2-, 3-suture MC with/without footprint repair, in a random order at 30° glenohumeral abduction. Passive stiffness of four anatomical regions in the SSP muscle was measured based on an established SWE method. Data were obtained from the SSP muscle at 0° abduction under 8 different conditions: intact (before making a tear, torn, and postoperative conditions with 6 techniques. MC techniques using 1-, or 2-suture combined with footprint repair showed significantly higher stiffness values than the intact condition. Passive stiffness of the SSP muscle was highest after a 1-suture MC with footprint repair for all regions when compared among all repair procedures. There was no significant difference between the intact condition and a 3-suture MC with footprint repair. MC techniques with single stitch and subsequent footprint repair may have adverse effects on muscle properties and tensile loading on repair, increasing the risk of retear of repairs. Adding more MC stitches could reverse these adverse effects.

  13. Semi-Nested Real-Time Reverse Transcription Polymerase Chain Reaction Methods for the Successful Quantitation of Cytokeratin mRNA Expression Levels for the Subtyping of Non-Small-Cell Lung Carcinoma Using Paraffin-Embedded and Microdissected Lung Biopsy Specimens

    International Nuclear Information System (INIS)

    Nakanishi, Yoko; Shimizu, Tetsuo; Tsujino, Ichiro; Obana, Yukari; Seki, Toshimi; Fuchinoue, Fumi; Ohni, Sumie; Oinuma, Toshinori; Kusumi, Yoshiaki; Yamada, Tsutomu; Takahashi, Noriaki; Hashimoto, Shu; Nemoto, Norimichi

    2013-01-01

    In patients with inoperable advanced non-small cell lung carcinomas (NSCLCs), histological subtyping using small-mount biopsy specimens was often required to decide the indications for drug treatment. The aim of this study was to assess the utility of highly sensitive mRNA quantitation for the subtyping of advanced NSCLC using small formalin fixing and paraffin embedding (FFPE) biopsy samples. Cytokeratin (CK) 6, CK7, CK14, CK18, and thyroid transcription factor (TTF)-1 mRNA expression levels were measured using semi-nested real-time quantitative (snq) reverse-transcribed polymerase chain reaction (RT-PCR) in microdissected tumor cells collected from 52 lung biopsies. Our results using the present snqRT-PCR method showed an improvement in mRNA quantitation from small FFPE samples, and the mRNA expression level using snqRT-PCR was correlated with the immunohistochemical protein expression level. CK7, CK18, and TTF-1 mRNA were expressed at significantly higher levels (P<0.05) in adenocarcinoma (AD) than in squamous cell carcinoma (SQ), while CK6 and CK14 mRNA expression was significantly higher (P<0.05) in SQ than in AD. Each histology-specific CK, particularly CK18 in AD and CK6 in SQ, were shown to be correlated with a poor prognosis (P=0.02, 0.02, respectively). Our results demonstrated that a quantitative CK subtype mRNA analysis from lung biopsy samples can be useful for predicting the histology subtype and prognosis of advanced NSCLC

  14. Quantitation of passive cutaneous anaphylaxis (PCA) by using radiolabelled antigen

    International Nuclear Information System (INIS)

    Ring, J.; Seifert, J.; Brendel, W.

    1978-01-01

    The major problem of detecting reaginic antibody by passive cutaneous anaphylaxis (PCA) is the quantitation of the dye reaction. Radiolabelled antigen was used in an attempt to quantitate the PCA reaction (Radio-PCA). Antisera containing reaginic antibody against human serum albumin (HSA) were produced in rabbits. These antisera were injected into normal rabbit skin in different dilutions. Twentyfour hours later HSA was injected intravenously either with Evans Blue or as 125-I-HSA. Radioactivity found in antibody-containing skin was significantly higher than in control specimens containing saline or normal rabbit serum, as low as antiserum dilutions of 1:1,000. Compared with Evans Blue technique Radio-PCA was able to distinguish quantitatively between different antiserum dilutions at a higher level of statistical significance. (author)

  15. Quantitative estimation of diacetylmorphine by preparative TLC and UV spectroscopy

    International Nuclear Information System (INIS)

    Khan, L.; Siddiqui, M.T.; Ahmad, N.; Shafi, N.

    2001-01-01

    A simple and efficient method for the quantitative estimation of di acetylmorphine in narcotic products has been described. Comparative TLC of narcotic specimens with standards showed presence of morphine, monoacetylmorphine, diacetylmorphine papaverine and noscapine, Resolution of the mixtures was achieved by preparative TLC. Bands corresponding to diacetylmorphine scraped, eluted UV absorption of extracts measured and contents quantified. (author)

  16. Review of quantitative phase-digital holographic microscopy: promising novel imaging technique to resolve neuronal network activity and identify cellular biomarkers of psychiatric disorders

    KAUST Repository

    Marquet, Pierre; Depeursinge, Christian; Magistretti, Pierre J.

    2014-01-01

    Quantitative phase microscopy (QPM) has recently emerged as a new powerful quantitative imaging technique well suited to noninvasively explore a transparent specimen with a nanometric axial sensitivity. In this review, we expose the recent

  17. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods are necessary to facilitate the fracture toughness testing of small disk compact specimens of irradiated candidate materials for first-wall fusion applications. New methods have been developed for both the unloading compliance and potential drop techniques of monitoring crack growth. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hot cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimen 12.7 mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  18. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1992-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (12.5 mm diam by 4.6 mm thick). Both unloading compliance and potential drop methods have been used to monitor crack extension during the J-integral resistance (J-R) curve testing. Provisions have been made to allow the necessary probes and instrumentation to be installed remotely using manipulators for testing of irradiated specimens in a hat cell. Laboratory trials showed that both unloading compliance and potential drop gave useful results. Both techniques gave similar data, and predicted the final crack extension within allowable limits. The results from the small disk compact specimens were similar to results from conventional compact specimens 12.7-mm thick. However, the slopes of the J-R curves from the larger specimens were lower, suggesting that the smaller disk compact specimens may have lost some constraint due to their size. The testing shows that it should be possible to generate useful J-R curve fracture toughness data from the small disk compact specimens

  19. 7 CFR 97.8 - Specimen requirements.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Specimen requirements. 97.8 Section 97.8 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Standards... required by the examiner to furnish representative specimens of the variety, or its flower, fruit, or seeds...

  20. Occurence of translocations between irradiated and intact chromosomes of Drosophila melanogaster

    International Nuclear Information System (INIS)

    Myasnyankina, E.N.; Abeleva, Eh.A.; Generalova, M.V.

    1980-01-01

    Two translocations between irradiated father and intact mother autosomes are obtained in Drosophila melanogaster. Five out of 283 regular translocations (between the second and the third chromosomes of an irradiated male) are accompanied by a recombination over the second or the third chromosomes. Nine flies out of twenty considered to be recombinants, could originate due to mutations. The data obtained prove that intact female autosomes can take part in the exchange with homologic (recombinations) and heterologic (translocations) irradiated male autosomes

  1. The correlation between histologic placentitis and amnionitis and the amnioniotic fluid's inflammatory cytokines in case of spontaneous pre-term labor with intact membrane

    Directory of Open Access Journals (Sweden)

    Agus Abadi

    2001-12-01

    Full Text Available Pre-term labor is presumed to result from spreading of lower genital infection to upper part, subsequently to decidual and choioamniotic tissues. Host response to this injury include the expression of protein which is responsible to the inflammatory reactions. The expression of the inflammatory cytokines such as IL-1β, IL-6, IL-8 and TNF-α increase in case of infection.These cytokines may play an essential role in the pathophysiology of spontaneous pretem labor with intact membrane.An observational analytic cohort study was caried out on cases of spontaneous pre-tefln labor with intact membrane. The objectives of this study are to examine the relationship between l the histologic amnionitis and placentitis and the incidence of preterm delivery,2 the expression of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α and the incidence of preterm delivery, 3 the level of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α and the grade of histologic amnionitis and placentitis in case of pre-term labor with intact membrane. Cases of spontaneous Pre'teftn labor with intact membrane which underwent transabdominal amniocentesis at admission and managed as standard procedure for pre-term labor with intact membrane. Atl of the cases were observed until the delivery of the baby, eithir preterm or term. The membrane and the placentawere cut postnatally and then the histologic acute inflammation eyaluated based on the criteria of Salafia.The level of amniotic fluid IL-1β, IL-6, IL-8 and TNF-α were analyzed quantitatively by Elisa method. This study showed thet the degree of histologic amnionitis and placentitis, and the level of amniotic fluid's IL-1β, IL-6, IL-8 and TNF-α were significantly higher in pre-term compared to terrn deliveries (p<0.05 and lhere were a positive correlation between the grade of histoLogic inflammation and the level of amniotic fluid's cytokines (Spearmann Rank Conelation test; p<0,05 in cases of preterm labor with intact membrane. The

  2. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    International Nuclear Information System (INIS)

    Tsuda, Hitoshi; Kurosumi, Masafumi; Umemura, Shinobu; Yamamoto, Sohei; Kobayashi, Takayuki; Osamura, Robert Yoshiyuki

    2010-01-01

    Accurate evaluation of human epidermal growth factor receptor type-2 (HER2) status based on core needle biopsy (CNB) specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC) and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH), the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71) for 3 × 3 categories (0-1+ versus 2+ versus 3+) and 90% (κ = 0.80) for 2 × 2 categories (0-2+ versus 3+). These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77) for 3 × 3 categories and 92% (κ = 0.88) for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77) for 3 × 3 categories, and 94% (κ = 0.83) for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of 2+ differed among specimens processed at

  3. HER2 testing on core needle biopsy specimens from primary breast cancers: interobserver reproducibility and concordance with surgically resected specimens

    Directory of Open Access Journals (Sweden)

    Yamamoto Sohei

    2010-10-01

    Full Text Available Abstract Background Accurate evaluation of human epidermal growth factor receptor type-2 (HER2 status based on core needle biopsy (CNB specimens is mandatory for identification of patients with primary breast cancer who will benefit from primary systemic therapy with trastuzumab. The aim of the present study was to validate the application of HER2 testing with CNB specimens from primary breast cancers in terms of interobserver reproducibility and comparison with surgically resected specimens. Methods A total of 100 pairs of archival formalin-fixed paraffin-embedded CNB and surgically resected specimens of invasive breast carcinomas were cut into sections. All 100 paired sections were subjected to HER2 testing by immunohistochemistry (IHC and 27 paired sections were subjected to that by fluorescence in situ hybridization (FISH, the results being evaluated by three and two observers, respectively. Interobserver agreement levels in terms of judgment and the concordance of consensus scores between CNB samples and the corresponding surgically resected specimens were estimated as the percentage agreement and κ statistic. Results In CNB specimens, the percentage interobserver agreement of HER2 scoring by IHC was 76% (κ = 0.71 for 3 × 3 categories (0-1+ versus 2+ versus 3+ and 90% (κ = 0.80 for 2 × 2 categories (0-2+ versus 3+. These levels were close to the corresponding ones for the surgically resected specimens: 80% (κ = 0.77 for 3 × 3 categories and 92% (κ = 0.88 for 2 × 2 categories. Concordance of consensus for HER2 scores determined by IHC between CNB and the corresponding surgical specimens was 87% (κ = 0.77 for 3 × 3 categories, and 94% (κ = 0.83 for 2 × 2 categories. Among the 13 tumors showing discordance in the mean IHC scores between the CNB and surgical specimens, the results of consensus for FISH results were concordant in 11. The rate of successful FISH analysis and the FISH positivity rate in cases with a HER2 IHC score of

  4. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens

    Science.gov (United States)

    Guan, YaoYao; Gravitt, Patti E.; Howard, Roslyn; Eby, Yolanda J.; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E.

    2016-01-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p = 0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. PMID:23370404

  5. Development and field application of a nonlinear ultrasonic modulation technique for fatigue crack detection without reference data from an intact condition

    Science.gov (United States)

    Lim, Hyung Jin; Kim, Yongtak; Koo, Gunhee; Yang, Suyoung; Sohn, Hoon; Bae, In-hwan; Jang, Jeong-Hwan

    2016-09-01

    In this study, a fatigue crack detection technique, which detects a fatigue crack without relying on any reference data obtained from the intact condition of a target structure, is developed using nonlinear ultrasonic modulation and applied to a real bridge structure. Using two wafer-type lead zirconate titanate (PZT) transducers, ultrasonic excitations at two distinctive frequencies are applied to a target inspection spot and the corresponding ultrasonic response is measured by another PZT transducer. Then, the nonlinear modulation components produced by a breathing-crack are extracted from the measured ultrasonic response, and a statistical classifier, which can determine if the nonlinear modulation components are statistically significant in comparison with the background noise level, is proposed. The effectiveness of the proposed fatigue crack detection technique is experimentally validated using the data obtained from aluminum plates and aircraft fitting-lug specimens under varying temperature and loading conditions, and through a field testing of Yeongjong Grand Bridge in South Korea. The uniqueness of this study lies in that (1) detection of a micro fatigue crack with less than 1 μm width and fatigue cracks in the range of 10-20 μm in width using nonlinear ultrasonic modulation, (2) automated detection of fatigue crack formation without using reference data obtained from an intact condition, (3) reliable and robust diagnosis under varying temperature and loading conditions, (4) application of a local fatigue crack detection technique to online monitoring of a real bridge.

  6. Molecular Auditing: An Evaluation of Unsuspected Tissue Specimen Misidentification.

    Science.gov (United States)

    Demetrick, Douglas J

    2018-06-18

    Context Specimen misidentification is the most significant error in laboratory medicine, potentially accounting for hundreds of millions of dollars in extra health care expenses and significant morbidity in patient populations in the United States alone. New technology allows the unequivocal documentation of specimen misidentification or contamination; however, the value of this technology currently depends on suspicion of the specimen integrity by a pathologist or other health care worker. Objective To test the hypothesis that there is a detectable incidence of unsuspected tissue specimen misidentification among cases submitted for routine surgical pathology examination. Design To test this hypothesis, we selected specimen pairs that were obtained at different times and/or different hospitals from the same patient, and compared their genotypes using standardized microsatellite markers used commonly for forensic human DNA comparison in order to identify unsuspected mismatches between the specimen pairs as a trial of "molecular auditing." We preferentially selected gastrointestinal, prostate, and skin biopsies because we estimated that these types of specimens had the greatest potential for misidentification. Results Of 972 specimen pairs, 1 showed an unexpected discordant genotype profile, indicating that 1 of the 2 specimens was misidentified. To date, we are unable to identify the etiology of the discordance. Conclusions These results demonstrate that, indeed, there is a low level of unsuspected tissue specimen misidentification, even in an environment with careful adherence to stringent quality assurance practices. This study demonstrates that molecular auditing of random, routine biopsy specimens can identify occult misidentified specimens, and may function as a useful quality indicator.

  7. Half the entanglement in critical systems is distillable from a single specimen

    International Nuclear Information System (INIS)

    Orus, R.; Latorre, J. I.; Eisert, J.; Cramer, M.

    2006-01-01

    We establish a quantitative relationship between the entanglement content of a single quantum chain at a critical point and the corresponding entropy of entanglement. We find that, surprisingly, the leading critical scaling of the single-copy entanglement with respect to any bipartitioning is exactly one-half of the entropy of entanglement, in a general setting of conformal field theory and quasifree systems. Conformal symmetry imposes that the single-copy entanglement scales as E 1 (ρ L )=(c/6)ln L-(c/6)(π 2 /ln L)+O(1/L), where L is the number of constituents in a block of an infinite chain and c denotes the central charge. This shows that from a single specimen of a critical chain, already half the entanglement can be distilled compared to the rate that is asymptotically available. The result is substantiated by a quantitative analysis for all translationally invariant quantum spin chains corresponding to all isotropic quasifree fermionic models. An example of the XY spin chain shows that away from criticality the above relation is maintained only near the quantum phase transition

  8. Comparison of polyvinyl alcohol- and formalin-preserved fecal specimens in the formalin-ether sedimentation technique for parasitological examination.

    OpenAIRE

    Carroll, M J; Cook, J; Turner, J A

    1983-01-01

    A total of 965 paired fecal specimens preserved in polyvinyl alcohol fixative and Formalin were processed by the Formalin-ether sedimentation technique. The effectiveness of the concentration procedures with material from each preservative was determined by comparing both diagnostic efficiency (percent identified) and quantitative egg and semiquantitative cyst counts. Of the 319 infections, 69.5% were detected in concentrates from both preservatives, 6.9% from polyvinyl alcohol only, and 23.5...

  9. Automatic Gleason grading of prostate cancer using quantitative phase imaging and machine learning

    Science.gov (United States)

    Nguyen, Tan H.; Sridharan, Shamira; Macias, Virgilia; Kajdacsy-Balla, Andre; Melamed, Jonathan; Do, Minh N.; Popescu, Gabriel

    2017-03-01

    We present an approach for automatic diagnosis of tissue biopsies. Our methodology consists of a quantitative phase imaging tissue scanner and machine learning algorithms to process these data. We illustrate the performance by automatic Gleason grading of prostate specimens. The imaging system operates on the principle of interferometry and, as a result, reports on the nanoscale architecture of the unlabeled specimen. We use these data to train a random forest classifier to learn textural behaviors of prostate samples and classify each pixel in the image into different classes. Automatic diagnosis results were computed from the segmented regions. By combining morphological features with quantitative information from the glands and stroma, logistic regression was used to discriminate regions with Gleason grade 3 versus grade 4 cancer in prostatectomy tissue. The overall accuracy of this classification derived from a receiver operating curve was 82%, which is in the range of human error when interobserver variability is considered. We anticipate that our approach will provide a clinically objective and quantitative metric for Gleason grading, allowing us to corroborate results across instruments and laboratories and feed the computer algorithms for improved accuracy.

  10. Thermal property testing technique on micro specimen

    International Nuclear Information System (INIS)

    Baba, Tetsuya; Kishimoto, Isao; Taketoshi, Naoyuki

    2000-01-01

    This study aims at establishment of further development on some testing techniques on the nuclear advanced basic research accumulated by the National Research Laboratory of Metrology for ten years. For this purpose, a technology to test heat diffusion ratio and specific heat capacity of less than 3 mm in diameter and 1 mm in thickness of micro specimen and technology to test heat diffusion ratio at micro area of less than 1 mm in area along cross section of less than 10 mm in diameter of column specimen were developed to contribute to common basic technology supporting the nuclear power field. As a result, as an element technology to test heat diffusion ratio and specific heat capacity of the micro specimen, a specimen holding technique stably to hold a micro specimen with 3 mm in diameter could be developed. And, for testing the specific heat capacity by using the laser flush differential calorimetry, a technique to hold two specimen of 5 mm in diameter at their proximities was also developed. In addition, by promoting development of thermal property data base capable of storing thermal property data obtained in this study and with excellent workability in this 1998 fiscal year a data in/out-put program with graphical user interface could be prepared. (G.K.)

  11. Comparative study on Charpy specimen reconstitution techniques

    International Nuclear Information System (INIS)

    Bourdiliau, B.; Decroix, G.-M.; Averty, X.; Wident, P.; Bienvenu, Y.

    2011-01-01

    Highlights: → Welding processes are used to reconstitute previously tested Charpy specimens. → Stud welding is preferred for a quick installation, almost immediately operational. → Friction welding produces better quality welds, but requires a development effort. - Abstract: Reconstitution techniques are often used to allow material from previously fractured Charpy-V specimens to be reused for additional experiments. This paper presents a comparative experimental study of various reconstitution techniques and evaluates the feasibility of these methods for future use in shielded cells. The following techniques were investigated: arc stud welding, 6.0 kW CO 2 continuous wave laser welding, 4.5 kW YAG continuous wave laser welding and friction welding. Subsize Charpy specimens were reconstituted using a 400 W YAG pulsed wave laser. The best result was obtained with arc stud welding; the resilience of the reconstituted specimens and the load-displacement curves agreed well with the reference specimens, and the temperature elevation caused by the welding process was limited to the vicinity of the weld. Good results were also obtained with friction welding; this process led to the best quality welds. Laser welding seems to have affected the central part of the specimens, thus leading to different resilience values and load-displacement curves.

  12. Enzymatic detection of formalin-fixed museum specimens for DNA analysis and enzymatic maceration of formalin-fixed specimens

    DEFF Research Database (Denmark)

    Sørensen, Margrethe; Redsted Rasmussen, Arne; Simonsen, Kim Pilkjær

    2016-01-01

    % ethanol. The method was subsequently tested on wild-living preserved specimens and an archived specimen. The protease enzyme used was SavinaseH 16 L, Type EX from Novozymes A/S. The enzymatic screening test demands only simple laboratory equipment. The method is useful for natural history collections...

  13. Capillary zone electrophoresis-mass spectromet of intact proteins

    NARCIS (Netherlands)

    Domínguez-Vega, Elena; Haselberg, Rob; Somsen, Govert W.

    2016-01-01

    Capillary electrophoresis (CE) coupled with mass spectrometry (MS) has proven to be a powerful analytical tool for the characterization of intact proteins. It combines the high separation efficiency, short analysis time, and versatility of CE with the mass selectivity and sensitivity offered by MS

  14. Closeout of JOYO-1 Specimen Fabrication Efforts

    International Nuclear Information System (INIS)

    ME Petrichek; JL Bump; RF Luther

    2005-01-01

    Fabrication was well under way for the JOYO biaxial creep and tensile specimens when the NR Space program was canceled. Tubes of FS-85, ASTAR-811C, and T-111 for biaxial creep specimens had been drawn at True Tube (Paso Robles, CA), while tubes of Mo-47.5 Re were being drawn at Rhenium Alloys (Cleveland, OH). The Mo-47.5 Re tubes are now approximately 95% complete. Their fabrication and the quantities produced will be documented at a later date. End cap material for FS-85, ASTAR-811C, and T-111 had been swaged at Pittsburgh Materials Technology, Inc. (PMTI) (Large, PA) and machined at Vangura (Clairton, PA). Cutting of tubes, pickling, annealing, and laser engraving were in process at PMTI. Several biaxial creep specimen sets of FS-85, ASTAR-811C, and T-111 had already been sent to Pacific Northwest National Laboratory (PNNL) for weld development. In addition, tensile specimens of FS-85, ASTAR-811C, T-111, and Mo-47.5 Re had been machined at Kin-Tech (North Huntington, PA). Actual machining of the other specimen types had not been initiated. Flowcharts 1-3 detail the major processing steps each piece of material has experienced. A more detailed description of processing will be provided in a separate document [B-MT(SRME)-51]. Table 1 lists the in-process materials and finished specimens. Also included are current metallurgical condition of these materials and specimens. The available chemical analyses for these alloys at various points in the process are provided in Table 2

  15. Losing a jewel—Rapid declines in Myanmar’s intact forests from 2002-2014

    Science.gov (United States)

    Horning, Ned; Khaing, Thiri; Thein, Zaw Min; Aung, Kyaw Moe; Aung, Kyaw Htet; Phyo, Paing; Tun, Ye Lin; Oo, Aung Htat; Neil, Anthony; Thu, Win Myo; Songer, Melissa; Huang, Qiongyu; Connette, Grant; Leimgruber, Peter

    2017-01-01

    New and rapid political and economic changes in Myanmar are increasing the pressures on the country’s forests. Yet, little is known about the past and current condition of these forests and how fast they are declining. We mapped forest cover in Myanmar through a consortium of international organizations and environmental non-governmental groups, using freely-available public domain data and open source software tools. We used Landsat satellite imagery to assess the condition and spatial distribution of Myanmar’s intact and degraded forests with special focus on changes in intact forest between 2002 and 2014. We found that forests cover 42,365,729 ha or 63% of Myanmar, making it one of the most forested countries in the region. However, severe logging, expanding plantations, and degradation pose increasing threats. Only 38% of the country’s forests can be considered intact with canopy cover >80%. Between 2002 and 2014, intact forests declined at a rate of 0.94% annually, totaling more than 2 million ha forest loss. Losses can be extremely high locally and we identified 9 townships as forest conversion hotspots. We also delineated 13 large (>100,000 ha) and contiguous intact forest landscapes, which are dispersed across Myanmar. The Northern Forest Complex supports four of these landscapes, totaling over 6.1 million ha of intact forest, followed by the Southern Forest Complex with three landscapes, comprising 1.5 million ha. These remaining contiguous forest landscape should have high priority for protection. Our project demonstrates how open source data and software can be used to develop and share critical information on forests when such data are not readily available elsewhere. We provide all data, code, and outputs freely via the internet at (for scripts: https://bitbucket.org/rsbiodiv/; for the data: http://geonode.themimu.info/layers/geonode%3Amyan_lvl2_smoothed_dec2015_resamp) PMID:28520726

  16. Localization by whole-body autoradiography of intact and fragmented radiolabeled antibodies in a metastatic human colonic cancer model

    International Nuclear Information System (INIS)

    Fand, Irwin; Sharkey, R.M.; Grundy, J.P.; Goldenberg, D.M.

    1992-01-01

    In this report, we have employed macroautoradiography to compare the tumor targeting of 125 I-labeled anti-carcinoembryonic antigen (CEA) MAb (NP-4) to 125 I-labeled anti-colon-specific antigen-p (CSAp) MAb (Mu-9) and their labeled F(ab') 2 and Fab' fragments, in nude mice each bearing large dorsal human colonic tumor xenografts, and small nodular tumors in the liver and lungs. Using intact MAbs (NP-4 and Mu-9), clearance of background radioactivity was delayed to 3-7 days post-treatment. Treatment with F(ab') 2 and Fab' fragments of both NP-4 and Mu-9 MAbs, however, promoted clearance of background 125 I-radioactivity which was well advanced by 6-24 h and complete by 24-48 h after injection. Localization of 125 I-radioactivity in large and micrometastatic tumor perimeters was the most characteristic uptake pattern observed for both intact and fragmented MAbs. Qualitative analysis of macroautoradiographic images and quantitative densitometry indicated that the higher tumor-to-blood ratios achieved with labeled F(ab') 2 and Fab' fragments at early time points, compared to labeled whole immunoglobulin, appeared to be more a function of rapid plasma clearance, tumor mass, location of xenografts and specific tumor growth patterns than increased tumor penetrance by lower molecular weight univalent and bivalent immune fragments. (Author)

  17. Non-intact zona improves development of murine preimplantation ...

    African Journals Online (AJOL)

    ajl5

    2012-09-25

    Sep 25, 2012 ... 2College of Animal Science and Technology, Northwest A & F University, Yangling, ... Key words: Mouse, non-intact zona embryos, adenovirus vector with green fluorescent protein (pAd-GFP), .... Based on microscopic examination, the ZP of some ..... permeable structure of ZP that allowed penetration of.

  18. Simultaneous specimen and stage cleaning device for analytical electron microscope

    Science.gov (United States)

    Zaluzec, Nestor J.

    1996-01-01

    An improved method and apparatus are provided for cleaning both a specimen stage, a specimen and an interior of an analytical electron microscope (AEM). The apparatus for cleaning a specimen stage and specimen comprising a plasma chamber for containing a gas plasma and an air lock coupled to the plasma chamber for permitting passage of the specimen stage and specimen into the plasma chamber and maintaining an airtight chamber. The specimen stage and specimen are subjected to a reactive plasma gas that is either DC or RF excited. The apparatus can be mounted on the analytical electron microscope (AEM) for cleaning the interior of the microscope.

  19. Quantitative chemoproteomics for site-specific analysis of protein alkylation by 4-hydroxy-2-nonenal in cells.

    Science.gov (United States)

    Yang, Jing; Tallman, Keri A; Porter, Ned A; Liebler, Daniel C

    2015-03-03

    Protein alkylation by 4-hydroxy-2-nonenal (HNE), an endogenous lipid derived electrophile, contributes to stress signaling and cellular toxicity. Although previous work has identified protein targets for HNE alkylation, the sequence specificity of alkylation and dynamics in a cellular context remain largely unexplored. We developed a new quantitative chemoproteomic platform, which uses isotopically tagged, photocleavable azido-biotin reagents to selectively capture and quantify the cellular targets labeled by the alkynyl analogue of HNE (aHNE). Our analyses site-specifically identified and quantified 398 aHNE protein alkylation events (386 cysteine sites and 12 histidine sites) in intact cells. This data set expands by at least an order of magnitude the number of such modification sites previously reported. Although adducts formed by Michael addition are thought to be largely irreversible, we found that most aHNE modifications are lost rapidly in situ. Moreover, aHNE adduct turnover occurs only in intact cells and loss rates are site-selective. This quantitative chemoproteomics platform provides a versatile general approach to map bioorthogonal-chemically engineered post-translational modifications and their cellular dynamics in a site-specific and unbiased manner.

  20. Agreement for HPV genotyping detection between self-collected specimens on a FTA cartridge and clinician-collected specimens.

    Science.gov (United States)

    Guan, Yaoyao; Gravitt, Patti E; Howard, Roslyn; Eby, Yolanda J; Wang, Shaoming; Li, Belinda; Feng, Changyan; Qiao, You-Lin; Castle, Philip E

    2013-04-01

    The current method of transporting self-collected cervicovaginal specimen for HPV DNA testing relies on liquid based medium, which is challenging and expensive to transport. A novel, dry storage and transportation device, Whatman indicating FTA™ Elute Cartridge, avoids some of the pitfalls of liquid-based medium. This method has been shown to be comparable to liquid-based collection medium, but relative performance of self-collected (SC) and clinician-collected (CC) samples onto FTA cards has not been reported. The objective of this study is to compare the analytic performance of self- and clinician-collected samples onto FTA cartridges for the detection of carcinogenic HPV using Linear Array. There was a 91% agreement, 69% positive agreement, and kappa of 0.75 between the clinician-collected and self-collected specimens for detection of any carcinogenic HPV genotype. When the HPV results were categorized hierarchically according to cervical cancer risk, there was no difference in the distribution of the HPV results for the clinician- and self-collected specimens (p=0.7). This study concludes that FTA elute cartridge is a promising method of specimen transport for cervical cancer screening programs considering using self-collected specimen and HPV testing. Larger studies with clinical endpoints are now needed to assess the clinical performance. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Quantitative MRI T2 relaxation time evaluation of knee cartilage: comparison of meniscus-intact and -injured knees after anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Li, Hong; Chen, Shuang; Tao, Hongyue; Chen, Shiyi

    2015-04-01

    Associated meniscal injury is well recognized at anterior cruciate ligament (ACL) reconstruction, and it is a known risk factor for osteoarthritis. To evaluate and characterize the postoperative appearance of articular cartilage after different meniscal treatment in ACL-reconstructed knees using T2 relaxation time evaluation on MRI. Cohort study; Level of evidence, 3. A total of 62 consecutive patients who under ACL reconstruction were recruited in this study, including 23 patients undergoing partial meniscectomy (MS group), 21 patients undergoing meniscal repair (MR group), and 18 patients with intact menisci (MI group) at time of surgery. Clinical evaluation, including subjective functional scores and physical examination, was performed on the same day as the MRI examination and at follow-up times ranging from 2 to 4.2 years. The MRI multiecho sagittal images were segmented to determine the T2 relaxation time value of each meniscus and articular cartilage plate. Differences in each measurement were compared among groups. No patient had joint-line tenderness or reported pain or clicking on McMurray test or instability. There were also no statistically significant differences in functional scores or medial or lateral meniscus T2 values among the 3 groups (P > .05 for both). There was a significantly higher articular cartilage T2 value in the medial femorotibial articular cartilage for the MS group (P T2 value between the MS and MR groups (P > .05) in each articular cartilage plate. The medial tibial articular cartilage T2 value had a significant positive correlation with medial meniscus T2 value (r = 0.287; P = .024) CONCLUSION: This study demonstrates that knees with meniscectomy or meniscal repair had articular cartilage degeneration at 2 to 4 years postoperatively, with higher articular cartilage T2 relaxation time values compared with the knees with an intact meniscus. © 2015 The Author(s).

  2. A cylindrical specimen holder for electron cryo-tomography

    International Nuclear Information System (INIS)

    Palmer, Colin M.; Löwe, Jan

    2014-01-01

    The use of slab-like flat specimens for electron cryo-tomography restricts the range of viewing angles that can be used. This leads to the “missing wedge” problem, which causes artefacts and anisotropic resolution in reconstructed tomograms. Cylindrical specimens provide a way to eliminate the problem, since they allow imaging from a full range of viewing angles around the tilt axis. Such specimens have been used before for tomography of radiation-insensitive samples at room temperature, but never for frozen-hydrated specimens. Here, we demonstrate the use of thin-walled carbon tubes as specimen holders, allowing the preparation of cylindrical frozen-hydrated samples of ribosomes, liposomes and whole bacterial cells. Images acquired from these cylinders have equal quality at all viewing angles, and the accessible tilt range is restricted only by the physical limits of the microscope. Tomographic reconstructions of these specimens demonstrate that the effects of the missing wedge are substantially reduced, and could be completely eliminated if a full tilt range was used. The overall quality of these tomograms is still lower than that obtained by existing methods, but improvements are likely in future. - Highlights: • The missing wedge is a serious problem for electron cryo-tomography. • Cylindrical specimens allow the missing wedge to be eliminated. • Carbon nanopipettes can be used as cylindrical holders for tomography of frozen-hydrated specimens. • Cryo-tomography of cylindrical biological samples demonstrates a reduction of deleterious effects associated with the missing wedge

  3. Quantitative phase imaging with scanning holographic microscopy: an experimental assesment

    Directory of Open Access Journals (Sweden)

    Tada Yoshitaka

    2006-11-01

    Full Text Available Abstract This paper demonstrates experimentally how quantitative phase information can be obtained in scanning holographic microscopy. Scanning holography can operate in both coherent and incoherent modes, simultaneously if desired, with different detector geometries. A spatially integrating detector provides an incoherent hologram of the object's intensity distribution (absorption and/or fluorescence, for example, while a point detector in a conjugate plane of the pupil provides a coherent hologram of the object's complex amplitude, from which a quantitative measure of its phase distribution can be extracted. The possibility of capturing simultaneously holograms of three-dimensional specimens, leading to three-dimensional reconstructions with absorption contrast, reflectance contrast, fluorescence contrast, as was previously demonstrated, and quantitative phase contrast, as shown here for the first time, opens up new avenues for multimodal imaging in biological studies.

  4. New Approach to Quantitative Analysis by Laser-induced Breakdown Spectroscopy

    International Nuclear Information System (INIS)

    Lee, D. H.; Kim, T. H.; Yun, J. I.; Jung, E. C.

    2009-01-01

    Laser-induced breakdown spectroscopy (LIBS) has been studied as the technique of choice in some particular situations like screening, in situ measurement, process monitoring, hostile environments, etc. Especially, LIBS can fulfill the qualitative and quantitative analysis for radioactive high level waste (HLW) glass in restricted experimental conditions. Several ways have been suggested to get quantitative information from LIBS. The one approach is to use the absolute intensities of each element. The other approach is to use the elemental emission intensities relative to the intensity of the internal standard element whose concentration is known already in the specimen. But these methods are not applicable to unknown samples. In the present work, we introduce new approach to LIBS quantitative analysis by using H α (656.28 nm) emission line as external standard

  5. Images of paraffin monolayer crystals with perfect contrast: Minimization of beam-induced specimen motion

    Energy Technology Data Exchange (ETDEWEB)

    Glaeser, R.M. [Lawrence Berkeley National Laboratory, University of California, Berkeley, CA 94720 (United States); McMullan, G.; Faruqi, A.R. [MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH (United Kingdom); Henderson, R., E-mail: rh15@mrc-lmb.cam.ac.uk [MRC Laboratory of Molecular Biology, Hills Road, Cambridge CB2 0QH (United Kingdom)

    2011-01-15

    Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation of the specimen causes beam-induced charging or movement, which in turn causes blurring of the image due to image or specimen movement. In this paper, we used three different approaches to try to overcome this image-blurring problem in monolayer crystals of paraffin. Our first approach was to use an extreme form of spotscan imaging, in which a single image was assembled on film by the successive illumination of up to 50,000 spots, each of a diameter of around 7 nm. The second approach was to use the Medipix II detector with its zero-noise readout to assemble a time-sliced series of images of the same area in which each frame from a movie with up to 400 frames had an exposure of only 500 electrons. In the third approach, we simply used a much thicker carbon support film to increase the physical strength and conductivity of the support. Surprisingly, the first two methods involving dose fractionation in space or time produced only partial improvements in contrast whereas the third approach produced many virtually perfect images, where the absolute contrast predicted from the electron diffraction amplitudes was observed in the images. We conclude that it is possible to obtain consistently almost perfect images of beam-sensitive specimens if they are attached to an appropriately strong and conductive support; however great care is needed in practice and the problem remains of how to best image ice-embedded biological structures in the absence of a strong, conductive support film. -- Research Highlights: {yields}Three ideas were tested to improve the contrast of images of an organic specimen. {yields}High-resolution images of paraffin on thick carbon films can have perfect

  6. Images of paraffin monolayer crystals with perfect contrast: Minimization of beam-induced specimen motion

    International Nuclear Information System (INIS)

    Glaeser, R.M.; McMullan, G.; Faruqi, A.R.; Henderson, R.

    2011-01-01

    Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation of the specimen causes beam-induced charging or movement, which in turn causes blurring of the image due to image or specimen movement. In this paper, we used three different approaches to try to overcome this image-blurring problem in monolayer crystals of paraffin. Our first approach was to use an extreme form of spotscan imaging, in which a single image was assembled on film by the successive illumination of up to 50,000 spots, each of a diameter of around 7 nm. The second approach was to use the Medipix II detector with its zero-noise readout to assemble a time-sliced series of images of the same area in which each frame from a movie with up to 400 frames had an exposure of only 500 electrons. In the third approach, we simply used a much thicker carbon support film to increase the physical strength and conductivity of the support. Surprisingly, the first two methods involving dose fractionation in space or time produced only partial improvements in contrast whereas the third approach produced many virtually perfect images, where the absolute contrast predicted from the electron diffraction amplitudes was observed in the images. We conclude that it is possible to obtain consistently almost perfect images of beam-sensitive specimens if they are attached to an appropriately strong and conductive support; however great care is needed in practice and the problem remains of how to best image ice-embedded biological structures in the absence of a strong, conductive support film. -- Research Highlights: →Three ideas were tested to improve the contrast of images of an organic specimen. →High-resolution images of paraffin on thick carbon films can have perfect contrast

  7. Quantitative characterization, classification and reconstruction of oocyst shapes of Eimeria species from cattle

    DEFF Research Database (Denmark)

    Sommer, C.

    1998-01-01

    by multivariate statistical techniques. The morphology of 810 Eimeria specimens was defined in binary (b/w) digital images by pixels of their oocyst outline. A Fourier transform of pixel positions yielded size and shape features. To classify coccidia, the quantitative data were employed in an agglomerative...

  8. Replacement/Refurbishment of JSC/NASA POD Specimens

    Science.gov (United States)

    Castner, Willard L.

    2010-01-01

    The NASA Special NDE certification process requires demonstration of NDE capability by test per NASA-STD-5009. This test is performed with fatigue cracked specimens containing very small cracks. The certification test results are usually based on binomial statistics and must meet a 90/95 Probability of Detection (POD). The assumption is that fatigue cracks are tightly closed, difficult to detect, and inspectors and processes passing such a test are well qualified for inspecting NASA fracture critical hardware. The JSC NDE laboratory has what may be the largest inventory that exists of such fatigue cracked NDE demonstration specimens. These specimens were produced by the hundreds in the late 1980s and early 1990s. None have been produced since that time and the condition and usability of the specimens are questionable.

  9. Creep life assessment of Mod.9Cr-1Mo steel. Pt. 2. Quantitative evaluation of microstructural damage in creep-interrupted specimens

    International Nuclear Information System (INIS)

    Sawada, Kota; Maruyama, Kouichi; Komine, Ryuji; Nagae, Yuji

    1998-02-01

    Mod.9Cr-1Mo steel has a martensitic lath structure. Recovery of the lath structure takes place in the course of creep. Microstructural degradation due to the recovery results in the acceleration of creep rate and the subsequent failure of a specimen. Change of lath width during creep of the steel was quantitatively investigated to propose a residual life assessment methodology based on the recovery process. Since the steel was tempered at 1053K, the lath structure is thermally stable at the testing temperatures (848K-923K). However, recovery of lath structure readily takes place during creep, indicating that the recovery is induced by creep deformation. Lath width d increases with creep strain and saturates to a value d s determined by creep stress. The increase of d is faster at a higher stress and temperature. A normalized change in lath width, Δd/Δd s , was introduced to explain the variation of lath growth rate with creep stress and temperature. Δd is the change in lath width from the initial value d 0 , and Δd s is the difference between d s and d 0 . Δd/Δd s is uniquely related to creep strain ε and the relationship is independent of creep stress as well as creep temperature. This Δd/Δd s -ε relationship obtained by an accelerated creep test at a higher temperature or stress is applicable to any creep condition including service conditions of engineering plants. Creep strain can be evaluated from the measurement of Δd/Δd s based on the Δd/Δd s -ε relationship. A creep curve under any creep condition can readily be calculated by creep data of the steel. Combining these information one can assess residual life of a structural component made of the steel. (author)

  10. The influence of specimen size on creep crack growth rate in cross-weld CT specimens cut out from a welded component

    International Nuclear Information System (INIS)

    Andersson, Peder; Segle, Peter; Samuelson, Lars Aa.

    1999-04-01

    A 3D finite element study of creep crack growth in cross-weld CT specimens with material properties of 2.25Cr1Mo at 550 deg C is carried out, where large strain and displacement theory is used. The creep crack growth rate is calculated using a creep ductility based damage model, in which the creep strain rate perpendicular to the crack plane ahead of the crack tip is integrated, considering the multiaxial stress state. The influence of specimen size on creep crack growth rate under constant load is given special attention, but the possibility to transfer results from cross-weld CT specimens to welded high temperature components is also investigated. The creep crack growth rate of a crack in a circumferentially welded pipe is compared with the creep crack growth rate of cross-weld CT specimens of three different sizes, cut out from the pipe. Although the constraint ahead of the crack tip is higher for a larger CT specimen, the creep crack growth rate is higher for a smaller specimen than for a larger one if they are loaded to attain the same stress intensity factor. If the specimens are loaded to the same C* value, however, a more complicated pattern occurs; depending on the material properties of the weldment constituents, the CT specimen with the intermediate size will either yield the highest or the lowest creep crack growth rate

  11. Intact deposition of cationic vesicles on anionic cellulose fibers: Role of vesicle size, polydispersity, and substrate roughness studied via streaming potential measurements.

    Science.gov (United States)

    Kumar, Abhijeet; Gilson, Laurent; Henrich, Franziska; Dahl, Verena; Kleinen, Jochen; Gambaryan-Roisman, Tatiana; Venzmer, Joachim

    2016-07-01

    Understanding the mechanism of intact vesicle deposition on solid surfaces is important for effective utilization of vesicles as active ingredient carriers in applications such as drug delivery and fabric softening. In this study, the deposition of large (davg=12μm) and small (davg=0.27μm) cationic vesicles of ditallowethylester dimethylammonium chloride (DEEDMAC) on smooth and rough anionic cellulose fibers is investigated. The deposition process is studied quantitatively using streaming potential measurements and spectrophotometric determination of DEEDMAC concentrations. Natural and regenerated cellulose fibers, namely cotton and viscose, having rough and smooth surfaces, respectively, are used as adsorbents. Equilibrium deposition data and profiles of substrate streaming potential variation with deposition are used to gain insights into the fate of vesicles upon deposition and the deposition mechanism. Intact deposition of DEEDMAC vesicles is ascertained based on streaming potential variation with deposition in the form of characteristic saturating profiles which symbolize particle-like deposition. The same is also confirmed by confocal fluorescence microscopy. Substrate roughness is found to considerably influence the deposition mechanism which, in a novel application of electrokinetic methods, is elucidated via streaming potential measurements. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Near-infrared reflectance spectroscopy for predicting amino acids content in intact processed animal proteins.

    Science.gov (United States)

    De la Haba, Maria José; Garrido-Varo, Ana; Guerrero-Ginel, José Emilio; Pérez-Marín, Dolores C

    2006-10-04

    Near-infrared calibrations were developed for the instantaneous prediction of amino acids composition of processed animal proteins (PAPs). Two sample presentation modes were compared (ground vs intact) for demonstrating the viability of the analysis in the intact form, avoiding the need for milling. Modified partial least-squares (MPLS) equations for the prediction of amino acids in PAPs were developed using the same set of samples (N = 92 PAPs) analyzed in ground and intact form and in three cups differing in the optical window size. The standard error for cross validation (SECV) and the coefficient of determination (1-VR) values yielded with the calibrations developed using the samples analyzed in the intact form showed similar or even better accuracy than those obtained with finely ground samples. The excellent predictive ability (1-VR > 0.90; CV marketing of these important protein feed ingredients, alleviating the costs and time associated with the routine quality controls.

  13. Evaluation of the Universal Viral Transport system for long-term storage of virus specimens for microbial forensics.

    Science.gov (United States)

    Hosokawa-Muto, Junji; Fujinami, Yoshihito; Mizuno, Natsuko

    2015-08-01

    Forensic microbial specimens, including bacteria and viruses, are collected at biocrime and bioterrorism scenes. Although it is preferable that the pathogens in these samples are alive and kept in a steady state, the samples may be stored for prolonged periods before analysis. Therefore, it is important to understand the effects of storage conditions on the pathogens contained within such samples. To evaluate the capacity to preserve viable virus and the viral genome, influenza virus was added to the transport medium of the Universal Viral Transport system and stored for over 3 months at various temperatures, after which virus titrations and quantitative analysis of the influenza hemagglutinin gene were performed. Although viable viruses became undetectable 29 days after the medium was stored at room temperature, viruses in the medium stored at 4°C were viable even after 99 days. A quantitative PCR analysis indicated that the hemagglutinin gene was maintained for 99 days at both 4°C and room temperature. Therefore, long-term storage at 4°C has little effect on viable virus and viral genes, so the Universal Viral Transport system can be useful for microbial forensics. This study provides important information for the handling of forensic virus specimens. Copyright © 2015 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  14. Quantitative transmission electron microscopy at atomic resolution

    International Nuclear Information System (INIS)

    Allen, L J; D'Alfonso, A J; Forbes, B D; Findlay, S D; LeBeau, J M; Stemmer, S

    2012-01-01

    In scanning transmission electron microscopy (STEM) it is possible to operate the microscope in bright-field mode under conditions which, by the quantum mechanical principle of reciprocity, are equivalent to those in conventional transmission electron microscopy (CTEM). The results of such an experiment will be presented which are in excellent quantitative agreement with theory for specimens up to 25 nm thick. This is at variance with the large contrast mismatch (typically between two and five) noted in equivalent CTEM experiments. The implications of this will be discussed.

  15. Quantitative multiphase analysis of archaeological bronzes by neutron diffraction

    CERN Document Server

    Siano, S; Celli, M; Pini, R; Salimbeni, R; Zoppi, M; Kockelmann, W A; Iozzo, M; Miccio, M; Moze, O

    2002-01-01

    In this paper, we report the first investigation on the potentials of neutron diffraction to characterize archaeological bronze artifacts. The preliminary feasibility of phase and structural analysis was demonstrated on standardised specimens with a typical bronze alloy composition. These were realised through different hardening and annealing cycles, simulating possible ancient working techniques. The Bragg peak widths that resulted were strictly dependent on the working treatment, thus providing an important analytical element to investigate ancient making techniques. The diagnostic criteria developed on the standardised specimens were then applied to study two Etruscan museum pieces. Quantitative multiphase analysis by Rietveld refinement of the diffraction patterns was successfully demonstrated. Furthermore, the analysis of patterns associated with different artifact elements also yielded evidence for some peculiar perspective of the neutron diffraction diagnostics in archeometric applications. (orig.)

  16. On impact testing of subsize Charpy V-notch type specimens

    International Nuclear Information System (INIS)

    Mikhail, A.S.; Nanstad, R.K.

    1994-01-01

    The potential for using subsize specimens to determine the actual properties of reactor pressure vessel steels is receiving increasing attention for improved vessel condition monitoring that could be beneficial for light-water reactor plant-life extension. This potential is made conditional upon, on the one hand, by the possibility of cutting samples of small volume from the internal surface of the pressure vessel for determination of actual properties of the operating pressure vessel. The plant-life extension will require supplemental surveillance data that cannot be provided by the existing surveillance programs. Testing of subsize specimens manufactured from broken halves of previously tested surveillance Charpy V-notch (CVN) specimens offers an attractive means of extending existing surveillance programs. Using subsize CVN type specimens requires the establishment of a specimen geometry that is adequate to obtain a ductile-to-brittle transition curve similar to that obtained from full-size specimens. This requires the development of a correlation of transition temperature and upper-shelf toughness between subsize and full-size specimens. The present study was conducted under the Heavy-Section Steel Irradiation Program. Different published approaches to the use of subsize specimens were analyzed and five different geometries of subsize specimens were selected for testing and evaluation. The specimens were made from several types of pressure vessel steels with a wide range of yield strengths, transition temperatures, and upper-shelf energies (USEs). Effects of specimen dimensions, including depth, angle, and radius of notch have been studied. The correlation of transition temperature determined from different types of subsize specimens and the full-size specimen is presented. A new procedure for transforming data from subsize specimens was developed and is presented

  17. Aboveground Biomass Variability Across Intact and Degraded Forests in the Brazilian Amazon

    Science.gov (United States)

    Longo, Marcos; Keller, Michael; Dos-Santos, Maiza N.; Leitold, Veronika; Pinage, Ekena R.; Baccini, Alessandro; Saatchi, Sassan; Nogueira, Euler M.; Batistella, Mateus; Morton, Douglas C.

    2016-01-01

    Deforestation rates have declined in the Brazilian Amazon since 2005, yet degradation from logging, re, and fragmentation has continued in frontier forests. In this study we quantified the aboveground carbon density (ACD) in intact and degraded forests using the largest data set of integrated forest inventory plots (n 359) and airborne lidar data (18,000 ha) assembled to date for the Brazilian Amazon. We developed statistical models relating inventory ACD estimates to lidar metrics that explained70 of the variance across forest types. Airborne lidar-ACD estimates for intact forests ranged between 5.0 +/- 2.5 and 31.9 +/- 10.8 kg C m(exp -2). Degradation carbon losses were large and persistent. Sites that burned multiple times within a decade lost up to 15.0 +/- 0.7 kg C m(-2)(94%) of ACD. Forests that burned nearly15 years ago had between 4.1 +/- 0.5 and 6.8 +/- 0.3 kg C m(exp -2) (22-40%) less ACD than intact forests. Even for low-impact logging disturbances, ACD was between 0.7 +/- 0.3 and 4.4 +/- 0.4 kg C m(exp -2)(4-21%) lower than unlogged forests. Comparing biomass estimates from airborne lidar to existing biomass maps, we found that regional and pan-tropical products consistently overestimated ACD in degraded forests, under-estimated ACD in intact forests, and showed little sensitivity to res and logging. Fine-scale heterogeneity in ACD across intact and degraded forests highlights the benefits of airborne lidar for carbon mapping. Differences between airborne lidar and regional biomass maps underscore the need to improve and update biomass estimates for dynamic land use frontiers, to better characterize deforestation and degradation carbon emissions for regional carbon budgets and Reduce Emissions from Deforestation and forest Degradation(REDD+).

  18. Mitochondrial and ER Calcium Uptake and Release Fluxes and their Interplay in Intact Nerve Cells

    Science.gov (United States)

    Friel, David D.

    Ionized free Ca ( Ca 2+) is a ubiquitous signaling ion that serves as the critical link between a variety of physiological stimuli and their intracellular effectors. Previous studies of reduced in vitro preparations have provided functional characterizations of various Ca 2+ channels, pumps and exchangers that regulate cellular Ca 2+ movements. However, little is known about the functional interplay between transporters that are expressed together in intact cells and orchestrate stimulus-evoked changes in [ Ca 2+]. This review summarizes recent progress in characterizing Ca 2+ transporters in sympathetic neurons, which provide an ideal model for studying Ca 2+ dynamics in neurons. Our results show how the functional interplay between Ca 2+ transport systems that are regulated by Ca 2+ in quantitatively differ-ent ways leads to emergent properties of Ca 2+ signaling that are expected to play a critical role in defining how Ca 2+ serves its role as a signaling ion.

  19. Application of subsize specimens in nuclear plant life extension

    International Nuclear Information System (INIS)

    Rosinski, S.T.; Kumar, A.S.; Cannon, N.S.; Hamilton, M.L.

    1993-01-01

    The US Department of Energy is sponsoring a research effort through Sandia National Laboratories and the University of Missouri-Rolla to test a correlation for the upper shelf energy (USE) values obtained from the impact testing of subsize Charpy V-notch specimens to those obtained from the testing of full-size samples. The program involves the impact testing of unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens. To verify the applicability of the correlation on LWR materials, unirradiated and irradiated full-, half-, and third-size Charpy V-notch specimens of a commercial pressure vessel steel (ASTM A533 Grade B) will be tested. The correlation methodology is based on the partitioning of the USE into crack initiation and crack propagation energies. To accomplish this partition, both precracked and notched-only specimens will be used. Whereas the USE of notched-only specimens is the sum of both crack initiation and crack propagation energies, the USE of precracked specimens reflects only the crack propagation component. The difference in the USE of the two types of specimens represents a measure of the crack initiation energy. Normalizing the values of the crack initiation energy to the fracture volume of the sample produces similar values for the full-, half-, and third-size specimens. In addition, the ratios of the USE and the crack propagation energy are also in agreement for full-, half-, and third-size specimens. These two observations will be used to predict the USE of full-size specimens based on subsize USE data. This paper provides details of the program and presents results obtained from the application of the developed correlation methodology to the impact testing of the unirradiated full-, half-, and third-size A533 Grade B Charpy V-notch specimens

  20. Phosphorylation of intact erythrocytes in human muscular dystrophy

    International Nuclear Information System (INIS)

    Johnson, R.M.; Nigro, M.

    1986-01-01

    The uptake of exogenous 32 Pi into the membrane proteins of intact erythrocytes was measured in 8 patients with Duchenne muscular dystrophy. No abnormalities were noted after autoradiographic analysis. This contrasts with earlier results obtained when isolated membranes were phosphorylated with gamma-[ 32 P]ATP, and suggests a possible reinterpretation of those experiments

  1. Quantification of Applied Stresses of C-Ring Specimens for Stress Corrosion Cracking Tests

    International Nuclear Information System (INIS)

    Kim, Woo Gon; Kim, Sun Jae; Rhee, Chang Kyu; Kuk, Il Hiun; Choi, Jong Ho

    1997-01-01

    For comparing their resistances for stress-corrosion cracking(SCC) in the K600-MA, K690-MA, and K600-TT tubes, C-ring specimens were fabricated with the various thermal-treatments to control the distributions of the precipitates like Cr-carbides. The bending stresses were analyzed to determine the amounts to make the stress quantitatively to all the C-ring samples, and then the stresses were calculated with the relation to the outer diameter(O.D) deflection(δ) of the C-rings. To measure accurately the bending strains of the C-ring specimens, the strain gauges were used and the compression test was also carried out. In the elastic region, the stresses in both the transverse and the circumferential directions were different with the locations of the strain gauges as attached at α= 30 .deg., 45 .deg., and 90 .deg. to the principal stress direction, but those in the longitudinal direction were independent of their attached locations. Calculated stresses from the strains obtained using the strain gauges were well agreed with the theoretical. In the plastic region over δ=1.0mm, the stresses for the TT tubes showed lower values of about 400MPa than those for the MA tubes. However, the stresses among the TT tubes showed almost the similar values in this region. Therefore, the states of the stresses applied to the C-ring specimens would be different with the material conditions, i.e, the chemical compositions, the thermal treatments such as MA and TT

  2. A non-destructive DNA sampling technique for herbarium specimens.

    Science.gov (United States)

    Shepherd, Lara D

    2017-01-01

    Herbarium specimens are an important source of DNA for plant research but current sampling methods require the removal of material for DNA extraction. This is undesirable for irreplaceable specimens such as rare species or type material. Here I present the first non-destructive sampling method for extracting DNA from herbarium specimens. DNA was successfully retrieved from robust leaves and/or stems of herbarium specimens up to 73 years old.

  3. Miniature tensile test specimens for fusion reactor irradiation studies

    International Nuclear Information System (INIS)

    Klueh, R.L.

    1985-01-01

    Three miniature sheet-type tensile specimens and a miniature rod-type specimen are being used to determine irradiated tensile properties for alloy development for fusion reactors. The tensile properties of type 316 stainless steel were determined with these different specimens, and the results were compared. Reasonably good agreement was observed. However, there were differences that led to recommendations on which specimens are preferred. 4 references, 9 figures, 6 tables

  4. Sympathetic Nervous Regulation of Calcium and Action Potential Alternans in the Intact Heart.

    Science.gov (United States)

    Winter, James; Bishop, Martin J; Wilder, Catherine D E; O'Shea, Christopher; Pavlovic, Davor; Shattock, Michael J

    2018-01-01

    Rationale: Arrhythmogenic cardiac alternans are thought to be an important determinant for the initiation of ventricular fibrillation. There is limited information on the effects of sympathetic nerve stimulation (SNS) on alternans in the intact heart and the conclusions of existing studies, focused on investigating electrical alternans, are conflicted. Meanwhile, several lines of evidence implicate instabilities in Ca handling, not electrical restitution, as the primary mechanism underpinning alternans. Despite this, there have been no studies on Ca alternans and SNS in the intact heart. The present study sought to address this, by application of voltage and Ca optical mapping for the simultaneous study of APD and Ca alternans in the intact guinea pig heart during direct SNS. Objective : To determine the effects of SNS on APD and Ca alternans in the intact guinea pig heart and to examine the mechanism(s) by which the effects of SNS are mediated. Methods and Results : Studies utilized simultaneous voltage and Ca optical mapping in isolated guinea pig hearts with intact innervation. Alternans were induced using a rapid dynamic pacing protocol. SNS was associated with rate-independent shortening of action potential duration (APD) and the suppression of APD and Ca alternans, as indicated by a shift in the alternans threshold to faster pacing rates. Qualitatively similar results were observed with exogenous noradrenaline perfusion. In contrast with previous reports, both SNS and noradrenaline acted to flatten the slope of the electrical restitution curve. Pharmacological block of the slow delayed rectifying potassium current (I Ks ), sufficient to abolish I Ks -mediated APD-adaptation, partially reversed the effects of SNS on pacing-induced alternans. Treatment with cyclopiazonic acid, an inhibitor of the sarco(endo)plasmic reticulum ATPase, had opposite effects to that of SNS, acting to increase susceptibility to alternans, and suggesting that accelerated Ca reuptake

  5. 10 CFR 26.165 - Testing split specimens and retesting single specimens.

    Science.gov (United States)

    2010-01-01

    ... (c), as applicable. If the specimen in Bottle A is free of any evidence of drugs or drug metabolites... suitable inquiry conducted under the provisions of § 26.63 or to any other inquiry or investigation... records must be provided to personnel conducting reviews, inquiries into allegations, or audits under the...

  6. Spontaneous and light-induced photon emission from intact brains of chick embryos

    Institute of Scientific and Technical Information of China (English)

    张锦珠; 于文斗; 孙彤

    1997-01-01

    Photon emission (PE) and light-induced photon emission(LPE) of intact brains isolated from chick embryos have been measured by using the single photon counting device. Experimental results showed that the intensi-ty level of photon emission was detected to be higher from intact brain than from the medium in which the brain was immerged during measuring, and the emission intensity was related to the developmental stages, the healthy situation of the measured embryos, and the freshness of isolated brains as well. After white light illumination, a short-life de-layed emission from intact brains was observed, and its relaxation behavior followed a hyperbolic rather than an expo-nential law. According to the hypothesis of biophoton emission originating from a delocalized coherent electromagnetic field and Frohlich’s idea of coherent long-range interactions in biological systems, discussions were made on the signifi-cance of photon emission in studying cell communication, biological regulation, living system’

  7. Predictors of attachment security in preschool children from intact and divorced families.

    Science.gov (United States)

    Nair, Hira; Murray, Ann D

    2005-09-01

    The authors selected 58 mother-child dyads from divorced and intact families to participate in a study on the impact of divorce on preschoolers' attachment security. The authors explored pathways that lead to security of attachment. They found that mothers from divorced families were younger, had lower income levels, and had lower levels of education compared with their intact counterparts. Divorced mothers also reported significantly higher levels of stress, depression, need for social support, and conflict with their spouses. Mothers from intact families were more likely to use positive (authoritative) parenting styles compared with divorced mothers. Children in the divorced group had lower security scores on the Attachment Q-Set instrument (E. Waters, 1995). Regression analyses indicated that parenting style made a direct (independent) contribution to attachment security. In addition, temperament was related to attachment security, but temperament did not diminish the association of parenting style with attachment security. Furthermore, regression analyses indicated that the relationship of divorce to attachment security was mediated by parenting style.

  8. Prediction of primary breast cancer size and T-stage using micro-computed tomography in lumpectomy specimens

    Directory of Open Access Journals (Sweden)

    Wafa M Sarraj

    2015-01-01

    Full Text Available Background: Histopathology is the only accepted method to measure and stage the breast tumor size. However, there is a need to find another method to measure and stage the tumor size when the pathological assessment is not available. Micro-computed tomography. (micro-CT has the ability to measure tumor in three dimensions in an intact lumpectomy specimen. In this study, we aimed to determine the accuracy of micro-CT to measure and stage the primary tumor size in breast lumpectomy specimens, as compared to the histopathology. Materials and Methods: Seventy-two women who underwent lumpectomy surgery at the Massachusetts General Hospital Department of Surgery from June 2011 to September 2011, and from August 2013 to December 2013 participated in this study. The lumpectomy specimens were scanned using micro-CT followed by routine pathological processing. The maximum dimension of the invasive breast tumor was obtained from the micro-CT image and was compared to the corresponding pathology report for each subject. Results: The invasive tumor size measurement by micro-CT was underestimated in 24. cases. (33%, overestimated in 37. cases. (51%, and matched it exactly in 11. cases. (15% compared to the histopathology measurement for all the cases. However, micro-CT T.stage classification differed from histopathology in only 11. (15.2% with 6. cases. (8.3% classified as a higher stage by micro-CT, and 5. cases. (6.9% classified as lower compared to histopathology. In addition, micro-CT demonstrated a statically significant strong agreement (κ =0.6, P < 0.05 with pathological tumor size and staging for invasive ductal carcinoma. (IDC group. In contrast, there was no agreement. (κ = .2, P = 0.67 between micro-CT and pathology in estimating and staging tumor size for invasive lobular carcinoma. (ILC group. This could be explained by a small sample size. (7 for ILC group. Conclusions: Micro-CT is a promising modality for measuring and staging the IDC.

  9. DNA DAMAGE QUANTITATION BY ALKALINE GEL ELECTROPHORESIS.

    Energy Technology Data Exchange (ETDEWEB)

    SUTHERLAND,B.M.; BENNETT,P.V.; SUTHERLAND, J.C.

    2004-03-24

    Physical and chemical agents in the environment, those used in clinical applications, or encountered during recreational exposures to sunlight, induce damages in DNA. Understanding the biological impact of these agents requires quantitation of the levels of such damages in laboratory test systems as well as in field or clinical samples. Alkaline gel electrophoresis provides a sensitive (down to {approx} a few lesions/5Mb), rapid method of direct quantitation of a wide variety of DNA damages in nanogram quantities of non-radioactive DNAs from laboratory, field, or clinical specimens, including higher plants and animals. This method stems from velocity sedimentation studies of DNA populations, and from the simple methods of agarose gel electrophoresis. Our laboratories have developed quantitative agarose gel methods, analytical descriptions of DNA migration during electrophoresis on agarose gels (1-6), and electronic imaging for accurate determinations of DNA mass (7-9). Although all these components improve sensitivity and throughput of large numbers of samples (7,8,10), a simple version using only standard molecular biology equipment allows routine analysis of DNA damages at moderate frequencies. We present here a description of the methods, as well as a brief description of the underlying principles, required for a simplified approach to quantitation of DNA damages by alkaline gel electrophoresis.

  10. Thick Concrete Specimen Construction, Testing, and Preliminary Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, Dwight A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hoegh, Kyle [Univ. of Minnesota, Minneapolis, MN (United States); Khazanovich, Lev [Univ. of Minnesota, Minneapolis, MN (United States)

    2015-03-01

    The purpose of the U.S. Department of Energy Office of Nuclear Energy’s Light Water Reactor Sustainability (LWRS) Program is to develop technologies and other solutions that can improve the reliability, sustain the safety, and extend the operating lifetimes of nuclear power plants (NPPs) beyond 60 years. Since many important safety structures in an NPP are constructed of concrete, inspection techniques must be developed and tested to evaluate the internal condition. In-service containment structures generally do not allow for the destructive measures necessary to validate the accuracy of these inspection techniques. This creates a need for comparative testing of the various nondestructive evaluation (NDE) measurement techniques on concrete specimens with known material properties, voids, internal microstructure flaws, and reinforcement locations. A preliminary report detailed some of the challenges associated with thick reinforced concrete sections and prioritized conceptual designs of specimens that could be fabricated to represent NPP concrete structures for using in NDE evaluation comparisons. This led to the construction of the concrete specimen presented in this report, which has sufficient reinforcement density and cross-sectional size to represent an NPP containment wall. Details on how a suitably thick concrete specimen was constructed are presented, including the construction materials, final nominal design schematic, as well as formwork and rigging required to safely meet the desired dimensions of the concrete structure. The report also details the type and methods of forming the concrete specimen as well as information on how the rebar and simulated defects were embedded. Details on how the resulting specimen was transported, safely anchored, and marked to allow access for systematic comparative NDE testing of defects in a representative NPP containment wall concrete specimen are also given. Data collection using the MIRA Ultrasonic NDE equipment and

  11. SOLITARY CHEMORECEPTOR CELL SURVIVAL IS INDEPENDENT OF INTACT TRIGEMINAL INNERVATION

    Science.gov (United States)

    Gulbransen, Brian; Silver, Wayne; Finger, Tom

    2008-01-01

    Nasal solitary chemoreceptor cells (SCCs) are a population of specialized chemosensory epithelial cells presumed to broaden trigeminal chemoreceptivity in mammals (Finger et al., 2003). SCCs are innervated by peptidergic trigeminal nerve fibers (Finger et al., 2003) but it is currently unknown if intact innervation is necessary for SCC development or survival. We tested the dependence of SCCs on innervation by eliminating trigeminal nerve fibers during development with neurogenin-1 knockout mice, during early postnatal development with capsaicin desensitization, and during adulthood with trigeminal lesioning. Our results demonstrate that elimination of innervation at any of these times does not result in decreased SCC numbers. In conclusion, neither SCC development nor mature cell maintenance is dependent on intact trigeminal innervation. PMID:18300260

  12. The impact of family intactness on family functioning, parental control and parent-child relational qualities in a Chinese context

    Directory of Open Access Journals (Sweden)

    Daniel Tan Lei Shek

    2015-01-01

    Full Text Available The current study investigated the differences between intact and non-intact families in family processes, including systematic family functioning, parental behavioral control, parental psychological control, and parent-child relational qualities. The participants were 3,328 Secondary One students, with a mean age of 12.59 years, recruited from 28 secondary schools in Hong Kong. Four validated scales were used to assess family processes. Results showed that adolescents in non-intact families perceived relatively poorer family functioning, lower level of paternal and maternal behavioral control, lower level of paternal psychological control and poorer parent-child relational qualities than did adolescents in intact families. This generally indicated that family processes were poorer in non-intact families, compared with those in intact families. The theoretical and practical implications of the findings were discussed.

  13. Handling of biological specimens for electron microscopy

    International Nuclear Information System (INIS)

    Bullock, G.

    1987-01-01

    There are many different aspects of specimen preparation procedure which need to be considered in order to achieve good results. Whether using the scanning or transmission microscope, the initial handling procedures are very similar and are selected for the information required. Handling procedures and techniques described are: structural preservation; immuno-and histo-chemistry; x-ray microanalysis and autoradiography; dehydration and embedding; mounting and coating specimens for scanning electron microscopy; and sectioning of resin embedded material. With attention to detail and careful choice of the best available technique, excellent results should be obtainable whatever the specimen. 6 refs

  14. Elastic-plastic analysis of the SS-3 tensile specimen

    International Nuclear Information System (INIS)

    Majumdar, S.

    1998-01-01

    Tensile tests of most irradiated specimens of vanadium alloys are conducted using the miniature SS-3 specimen which is not ASTM approved. Detailed elastic-plastic finite element analysis of the specimen was conducted to show that, as long as the ultimate to yield strength ratio is less than or equal to 1.25 (which is satisfied by many irradiated materials), the stress-plastic strain curve obtained by using such a specimen is representative of the true material behavior

  15. Progress Report on Alloy 617 Notched Specimen Testing

    Energy Technology Data Exchange (ETDEWEB)

    McMurtrey, Michael David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Wright, Richard Neil [Idaho National Lab. (INL), Idaho Falls, ID (United States); Lillo, Thomas Martin [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-08-01

    Creep behavior of Alloy 617 has been extensively characterized to support the development of a draft Code Case to qualify Alloy 617 in Section III division 5 of the ASME Boiler and Pressure Vessel Code. This will allow use of Alloy 617 in construction of nuclear reactor components at elevated temperatures and longer periods of time (up to 950°C and 100,000 hours). Prior to actual use, additional concerns not considered in the ASME code need to be addressed. Code Cases are based largely on uniaxial testing of smooth gage specimens. In service conditions, components will generally be under multi axial loading. There is also the concern of the behavior at discontinuities, such as threaded components. To address the concerns of multi axial creep behavior and at geometric discontinuities, notched specimens have been designed to create conditions representative of the states that service components experience. Two general notch geometries have been used for these series of tests: U notch and V notch specimens. The notches produce a tri axial stress state, though not uniform across the specimen. Characterization of the creep behavior of the U notch specimens and the creep rupture behavior of the V notch specimens provides a good approximation of the behavior expected of actual components. Preliminary testing and analysis have been completed and are reported in this document. This includes results from V notch specimens tested at 900°C and 800°C. Failure occurred in the smooth gage section of the specimen rather than at the root of the notch, though some damage was present at the root of the notch, where initial stress was highest. This indicates notch strengthening behavior in this material at these temperatures.

  16. Scanning transmission ion micro-tomography (STIM-T) of biological specimens

    International Nuclear Information System (INIS)

    Schwertner, Michael; Sakellariou, Arthur; Reinert, Tilo; Butz, Tilman

    2006-01-01

    Computed tomography (CT) was applied to sets of Scanning Transmission Ion Microscopy (STIM) projections recorded at the LIPSION ion beam laboratory (Leipzig) in order to visualize the 3D-mass distribution in several specimens. Examples for a test structure (copper grid) and for biological specimens (cartilage cells, cygospore) are shown. Scanning Transmission Micro-Tomography (STIM-T) at a resolution of 260 nm was demonstrated for the first time. Sub-micron features of the Cu-grid specimen were verified by scanning electron microscopy. The ion energy loss measured during a STIM-T experiment is related to the mass density of the specimen. Typically, biological specimens can be analysed without staining. Only shock freezing and freeze-drying is required to preserve the ultra-structure of the specimen. The radiation damage to the specimen during the experiment can be neglected. This is an advantage compared to other techniques like X-ray micro-tomography. At present, the spatial resolution is limited by beam position fluctuations and specimen vibrations

  17. Final Report: Posttest Analysis of Omega II Optical Specimens

    International Nuclear Information System (INIS)

    Newlander, C D; Fisher, J H

    2007-01-01

    Preliminary posttest analyses have been completed on optical specimens exposed during the Omega II test series conducted on 14 July 2006. The Omega Facility, located at the Laboratory for Laser Energetics (LLE) at the University of Rochester was used to produce X-ray environments through the interaction of intense pulsed laser radiation upon germanium-loaded silica aerogels. The optical specimen testing was supported by GH Systems through experiment design, pre- and post-test analyses, specimen acquisition, and overall technical experience. The test specimens were fabricated and characterized by Surface Optics Corporation (SOC), San Diego, CA and were simple protected gold coatings on silica substrates. Six test specimens were exposed, five filtered with thin beryllium foil filters, and one unfiltered which was exposed directly to the raw environment. The experimental objectives were: (1) demonstrate that tests of optical specimens could be performed at the Omega facility; (2) evaluate the use and survivability of beryllium foil filters as a function of thickness; (3) obtain damage data on optical specimens which ranged from no damage to damage; (4) correlate existing thermal response models with the damage data; (5) evaluate the use of the direct raw environment upon the specimen response and the ability/desirability to conduct sensitive optical specimen tests using the raw environment; and (6) initiate the development of a protocol for performing optical coatings/mirror tests. This report documents the activities performed by GH Systems in evaluating and using the environments provided by LLNL, the PUFFTFT analyses performed using those environments, and the calculated results compared to the observed and measured posttest data

  18. Global forest loss disproportionately erodes biodiversity in intact landscapes.

    Science.gov (United States)

    Betts, Matthew G; Wolf, Christopher; Ripple, William J; Phalan, Ben; Millers, Kimberley A; Duarte, Adam; Butchart, Stuart H M; Levi, Taal

    2017-07-27

    Global biodiversity loss is a critical environmental crisis, yet the lack of spatial data on biodiversity threats has hindered conservation strategies. Theory predicts that abrupt biodiversity declines are most likely to occur when habitat availability is reduced to very low levels in the landscape (10-30%). Alternatively, recent evidence indicates that biodiversity is best conserved by minimizing human intrusion into intact and relatively unfragmented landscapes. Here we use recently available forest loss data to test deforestation effects on International Union for Conservation of Nature Red List categories of extinction risk for 19,432 vertebrate species worldwide. As expected, deforestation substantially increased the odds of a species being listed as threatened, undergoing recent upgrading to a higher threat category and exhibiting declining populations. More importantly, we show that these risks were disproportionately high in relatively intact landscapes; even minimal deforestation has had severe consequences for vertebrate biodiversity. We found little support for the alternative hypothesis that forest loss is most detrimental in already fragmented landscapes. Spatial analysis revealed high-risk hot spots in Borneo, the central Amazon and the Congo Basin. In these regions, our model predicts that 121-219 species will become threatened under current rates of forest loss over the next 30 years. Given that only 17.9% of these high-risk areas are formally protected and only 8.9% have strict protection, new large-scale conservation efforts to protect intact forests are necessary to slow deforestation rates and to avert a new wave of global extinctions.

  19. Some recent innovations in small specimen testing

    International Nuclear Information System (INIS)

    Odette, G.R.; He, M.; Gragg, D.; Klingensmith, D.; Lucas, G.E.

    2002-01-01

    New innovative small specimen test techniques are described. Finite element simulations show that combinations of cone indentation pile-up geometry and load-penetration depth relations can be used to determine both the yield stress and strain-hardening behavior of a material. Techniques for pre-cracking and testing sub-miniaturized fracture toughness bend bars, with dimensions of 1.65x1.65x9 mm 3 , or less, are described. The corresponding toughness-temperature curves have a very steep transition slope, primarily due to rapid loss of constraint, which has advantages in some experiments to characterize the effects of specified irradiation variables. As one example of using composite specimens, an approach to evaluating helium effects is proposed, involving diffusion bonding small wires of a 54 Fe-based ferritic-martensitic alloy to a surrounding fracture specimen composed of an elemental Fe-based alloy. Finally, we briefly outline some potential approaches to multipurpose specimens and test automation

  20. Blood specimen labelling errors: Implications for nephrology nursing practice.

    Science.gov (United States)

    Duteau, Jennifer

    2014-01-01

    Patient safety is the foundation of high-quality health care, as recognized both nationally and worldwide. Patient blood specimen identification is critical in ensuring the delivery of safe and appropriate care. The practice of nephrology nursing involves frequent patient blood specimen withdrawals to treat and monitor kidney disease. A critical review of the literature reveals that incorrect patient identification is one of the major causes of blood specimen labelling errors. Misidentified samples create a serious risk to patient safety leading to multiple specimen withdrawals, delay in diagnosis, misdiagnosis, incorrect treatment, transfusion reactions, increased length of stay and other negative patient outcomes. Barcode technology has been identified as a preferred method for positive patient identification leading to a definitive decrease in blood specimen labelling errors by as much as 83% (Askeland, et al., 2008). The use of a root cause analysis followed by an action plan is one approach to decreasing the occurrence of blood specimen labelling errors. This article will present a review of the evidence-based literature surrounding blood specimen labelling errors, followed by author recommendations for completing a root cause analysis and action plan. A failure modes and effects analysis (FMEA) will be presented as one method to determine root cause, followed by the Ottawa Model of Research Use (OMRU) as a framework for implementation of strategies to reduce blood specimen labelling errors.

  1. Quantitative study of magnetic field distribution by electron holography and micromagnetic simulations

    International Nuclear Information System (INIS)

    Beleggia, M.; Schofield, M.A.; Zhu, Y.; Malac, M.; Liu, Z.; Freeman, M.

    2003-01-01

    The magnetic configuration of a submicrometer Ni 88 Fe 12 permalloy island has been quantitatively mapped by off-axis electron holography. The two main contributions to the electron-optical phase shift, namely the phase shifts induced by the electrostatic and magnetic potentials, including fringing fields, were separated by inverting the specimen of 180 deg. with respect to the electron beam and directly measuring the mean inner potential. A quantitative map of the projected magnetic induction in the sample was thereby retrieved and compared to results of micromagnetic and electromagnetic calculations, providing the minimum-energy configuration and the phase shift, respectively

  2. Molecular changes preceding endometrial and ovarian cancer: a study of consecutive endometrial specimens from Lynch syndrome surveillance.

    Science.gov (United States)

    Niskakoski, Anni; Pasanen, Annukka; Lassus, Heini; Renkonen-Sinisalo, Laura; Kaur, Sippy; Mecklin, Jukka-Pekka; Bützow, Ralf; Peltomäki, Päivi

    2018-03-27

    Molecular alterations preceding endometrial and ovarian cancer and the sequence of events are unknown. Consecutive specimens from lifelong surveillance for Lynch syndrome provides a natural setting to address such questions. To molecularly define the multistep gynecological tumorigenesis, DNA mismatch repair gene mutation carriers with endometrial or ovarian carcinoma or endometrial hyperplasia were identified from a nation-wide registry and endometrial biopsy specimens taken from these individuals during 20 years of screening were collected. A total of 213 endometrial and ovarian specimens from Lynch syndrome individuals and 197 histology-matched (non-serous) samples from sporadic cases were available for this investigation. The specimens were profiled for markers linked to endometrial and ovarian tumorigenesis, including ARID1A protein expression, mismatch repair status, and tumor suppressor gene promoter methylation. In Lynch syndrome-associated endometrial and ovarian carcinomas, ARID1A protein was lost in 61-100% and mismatch repair was deficient in 97-100%, compared to 0-17% and 14-44% in sporadic cases (P = 0.000). ARID1A loss appeared in complex hyperplasia and deficient mismatch repair and tumor suppressor gene promoter methylation in histologically normal endometrium. Despite quantitative differences between Lynch syndrome and sporadic cases, ARID1A expression, mismatch repair, and tumor suppressor gene promoter methylation divided endometrial samples from both patient groups into three categories of increasing abnormality, comprising normal endometrium and simple hyperplasia (I), complex hyperplasia with or without atypia (II), and endometrial cancer (III). Complex hyperplasias without vs. with atypia were molecularly indistinguishable. In conclusion, surveillance specimens from Lynch syndrome identify mismatch repair deficiency, tumor suppressor gene promoter methylation, and ARID1A loss as early changes in tumor development. Our findings are

  3. Superolateral Dislocation of Intact Mandibular Condyle: A Case Report and Review of Literature

    OpenAIRE

    Saikrishna, Degala; Shyam Sundar, S.; Mamata, K. S.

    2015-01-01

    Anteromedial fracture dislocation of the mandibular condyle is common but a superolateral dislocation of an intact condyle is quite rare. This type of dislocation is often misdiagnosed or completely overlooked and hence inadequately addressed. We report a case of a 41-year-old male patient who experienced superolateral dislocation of the intact condyle with symphysis fracture and panfacial fracture following a road-traffic accident, and review of literature of superolateral dislocations from ...

  4. Prediction of valid acidity in intact apples with Fourier transform near infrared spectroscopy*

    OpenAIRE

    Liu, Yan-de; Ying, Yi-bin; Fu, Xia-ping

    2005-01-01

    To develop nondestructive acidity prediction for intact Fuji apples, the potential of Fourier transform near infrared (FT-NIR) method with fiber optics in interactance mode was investigated. Interactance in the 800 nm to 2619 nm region was measured for intact apples, harvested from early to late maturity stages. Spectral data were analyzed by two multivariate calibration techniques including partial least squares (PLS) and principal component regression (PCR) methods. A total of 120 Fuji appl...

  5. Tension test system for irradiated small specimens operated by remote control

    International Nuclear Information System (INIS)

    Okada, Akira

    1993-01-01

    A robot-based tension test system has been developed to aid in the mechanical testing of highly radioactive specimens. This system reduces radiation hazards from specimens and allows for the uniform precision of testing results independent of experimenters' skills. The robot system is designed to accommodate a miniaturized tension specimen with a gage section 5.5 by 1.2 mm, with a total length and width of 12.5 and 2.3 mm, respectively, and thickness of about 0.2 mm. The system is composed of a manipulating robot, a vibrational-type specimen feeder, a rotating-type specimen tray, a specimen observation system, a simulated tension text fixture, and a microcomputer for controlling the system. This system accomplishes specimen arrangement in the specimen tray, specimen transportation and loading to the test fixture and testing, and removal of the broken specimen from the fixture. These procedures are performed quickly, safely, and with uniform testing precision by computer control remotely by an unskilled experimenter

  6. Visual characterization and quantitative measurement of artemisinin-induced DNA breakage

    Energy Technology Data Exchange (ETDEWEB)

    Cai Huaihong [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China); Yang Peihui [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China)], E-mail: typh@jnu.edu.cn; Chen Jianan [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China); Liang Zhihong [Experiment and Technology Center, Jinan University, Guangzhou 510632 (China); Chen Qiongyu [Institute of Genetic Engineering, Jinan University, Guangzhou 510632 (China); Cai Jiye [Bionanotechnology Lab, and Department of Chemistry, Jinan University, Guangzhou 510632 (China)], E-mail: tjycai@jnu.edu.cn

    2009-05-01

    DNA conformational change and breakage induced by artemisinin, a traditional Chinese herbal medicine, have been visually characterized and quantitatively measured by the multiple tools of electrochemistry, UV-vis absorption spectroscopy, atomic force microscopy (AFM), and DNA electrophoresis. Electrochemical and spectroscopic results confirm that artemisinin can intercalate into DNA double helix, which causes DNA conformational changes. AFM imaging vividly demonstrates uneven DNA strand breaking induced by QHS interaction. To assess these DNA breakages, quantitative analysis of the extent of DNA breakage has been performed by analyzing AFM images. Basing on the statistical analysis, the occurrence of DNA breaks is found to depend on the concentration of artemisinin. DNA electrophoresis further validates that the intact DNA molecules are unwound due to the breakages occur at the single strands. A reliable scheme is proposed to explain the process of artemisinin-induced DNA cleavage. These results can provide further information for better understanding the anticancer activity of artemisinin.

  7. Tensile-Creep Test Specimen Preparation Practices of Surface Support Liners

    Science.gov (United States)

    Guner, Dogukan; Ozturk, Hasan

    2017-12-01

    Ground support has always been considered as a challenging issue in all underground operations. Many forms of support systems and supporting techniques are available in the mining/tunnelling industry. In the last two decades, a new polymer based material, Thin Spray-on Liner (TSL), has attained a place in the market as an alternative to the current areal ground support systems. Although TSL provides numerous merits and has different application purposes, the knowledge on mechanical properties and performance of this material is still limited. In laboratory studies, since tensile rupture is the most commonly observed failure mechanism in field applications, researchers have generally studied the tensile testing of TSLs with modification of American Society for Testing and Materials (ASTM) D-638 standards. For tensile creep testing, specimen preparation process also follows the ASTM standards. Two different specimen dimension types (Type I, Type IV) are widely preferred in TSL tensile testing that conform to the related standards. Moreover, molding and die cutting are commonly used specimen preparation techniques. In literature, there is a great variability of test results due to the difference in specimen preparation techniques and practices. In this study, a ductile TSL product was tested in order to investigate the effect of both specimen preparation techniques and specimen dimensions under 7-day curing time. As a result, ultimate tensile strength, tensile yield strength, tensile modulus, and elongation at break values were obtained for 4 different test series. It is concluded that Type IV specimens have higher strength values compared to Type I specimens and moulded specimens have lower results than that of prepared by using die cutter. Moreover, specimens prepared by molding techniques have scattered test results. Type IV specimens prepared by die cutter technique are suggested for preparation of tensile test and Type I specimens prepared by die cutter technique

  8. Multi-Axis Prosthetic Knee Resembles Alpine Skiing Movements of an Intact Leg

    Directory of Open Access Journals (Sweden)

    Ivan Demšar, Jože Duhovnik, Blaž Lešnik, Matej Supej

    2015-12-01

    Full Text Available The purpose of the study was to analyse the flexion angles of the ski boot, ankle and knee joints of an above-knee prosthesis and to compare them with an intact leg and a control group of skiers. One subject with an above-knee amputation of the right leg and eight healthy subjects simulated the movement of a skiing turn by performing two-leg squats in laboratory conditions. By adding additional loads in proportion to body weight (BW; +1/3 BW, +2/3 BW, +3/3 BW, various skiing regimes were simulated. Change of Flexion Angle (CoFA and Range of Motion (RoM in the ski boot, ankle and knee joints were calculated and compared. An average RoM in the skiing boot on the side of prosthesis (4.4 ± 1.1° was significantly lower compared to an intact leg (5.9 ± 1.8° and the control group (6.5 ± 2.3°. In the ankle joint, the average RoM was determined to be 13.2±2.9° in the prosthesis, 12.7 ± 2.8° in an intact leg and 14.8±3.6 in the control group. However, the RoM of the knee joint in the prosthesis (42.2 ± 4.2° was significantly larger than that of the intact leg (34.7 ± 4.4°. The average RoM of the knee joint in the control group was 47.8 ± 5.4°. The influences of additional loads on the kinematics of the lower extremities were different on the side of the prosthesis and on the intact leg. In contrast, additional loads did not produce any significant differences in the control group. Although different CoFAs in the ski boot, ankle and knee joints were used, an above-knee prosthesis with a built-in multi-axis prosthetic knee enables comparable leg kinematics in simulated alpine skiing.

  9. AGC-2 Specimen Post Irradiation Data Package Report

    Energy Technology Data Exchange (ETDEWEB)

    Windes, William Enoch [Idaho National Lab. (INL), Idaho Falls, ID (United States); Swank, W. David [Idaho National Lab. (INL), Idaho Falls, ID (United States); Rohrbaugh, David T. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Cottle, David L. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-08-01

    This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens were subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between

  10. Micro-CTvlab: A web based virtual gallery of biological specimens using X-ray microtomography (micro-CT).

    Science.gov (United States)

    Keklikoglou, Kleoniki; Faulwetter, Sarah; Chatzinikolaou, Eva; Michalakis, Nikitas; Filiopoulou, Irene; Minadakis, Nikos; Panteri, Emmanouela; Perantinos, George; Gougousis, Alexandros; Arvanitidis, Christos

    2016-01-01

    During recent years, X-ray microtomography (micro-CT) has seen an increasing use in biological research areas, such as functional morphology, taxonomy, evolutionary biology and developmental research. Micro-CT is a technology which uses X-rays to create sub-micron resolution images of external and internal features of specimens. These images can then be rendered in a three-dimensional space and used for qualitative and quantitative 3D analyses. However, the online exploration and dissemination of micro-CT datasets are rarely made available to the public due to their large size and a lack of dedicated online platforms for the interactive manipulation of 3D data. Here, the development of a virtual micro-CT laboratory (Micro-CT vlab ) is described, which can be used by everyone who is interested in digitisation methods and biological collections and aims at making the micro-CT data exploration of natural history specimens freely available over the internet. The Micro-CT vlab offers to the user virtual image galleries of various taxa which can be displayed and downloaded through a web application. With a few clicks, accurate, detailed and three-dimensional models of species can be studied and virtually dissected without destroying the actual specimen. The data and functions of the Micro-CT vlab can be accessed either on a normal computer or through a dedicated version for mobile devices.

  11. Modeling of electron-specimen interaction in scanning electron microscope for e-beam metrology and inspection: challenges and perspectives

    Science.gov (United States)

    Suzuki, Makoto; Kameda, Toshimasa; Doi, Ayumi; Borisov, Sergey; Babin, Sergey

    2018-03-01

    The interpretation of scanning electron microscopy (SEM) images of the latest semiconductor devices is not intuitive and requires comparison with computed images based on theoretical modeling and simulations. For quantitative image prediction and geometrical reconstruction of the specimen structure, the accuracy of the physical model is essential. In this paper, we review the current models of electron-solid interaction and discuss their accuracy. We perform the comparison of the simulated results with our experiments of SEM overlay of under-layer, grain imaging of copper interconnect, and hole bottom visualization by angular selective detectors, and show that our model well reproduces the experimental results. Remaining issues for quantitative simulation are also discussed, including the accuracy of the charge dynamics, treatment of beam skirt, and explosive increase in computing time.

  12. Visual Speech Fills in Both Discrimination and Identification of Non-Intact Auditory Speech in Children

    Science.gov (United States)

    Jerger, Susan; Damian, Markus F.; McAlpine, Rachel P.; Abdi, Herve

    2018-01-01

    To communicate, children must discriminate and identify speech sounds. Because visual speech plays an important role in this process, we explored how visual speech influences phoneme discrimination and identification by children. Critical items had intact visual speech (e.g. baez) coupled to non-intact (excised onsets) auditory speech (signified…

  13. A Debonded Sandwich Specimen Under Mixed Mode Bending (MMB)

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2008-01-01

    Face/core interface crack propagation in sandwich specimens is analyzed. A thorough analysis of the typical failure modes in sandwich composites was performed in order to design the MMB specimen to promote face/core debond fracture. Displacement, compliance and energy release rate expressions...... for the MMB specimen were derived from a superposition analysis. An experimental verification of the methodology proposed was performed using MMB sandwich specimens with H100 PVC foam core and E-glass/polyester non-crimp quadro-axial [0/45/90/-45]s DBLT-850 faces. Different mixed mode loadings were applied...

  14. Simple and fast spectral domain algorithm for quantitative phase imaging of living cells with digital holographic microscopy

    Science.gov (United States)

    Min, Junwei; Yao, Baoli; Ketelhut, Steffi; Kemper, Björn

    2017-02-01

    The modular combination of optical microscopes with digital holographic microscopy (DHM) has been proven to be a powerful tool for quantitative live cell imaging. The introduction of condenser and different microscope objectives (MO) simplifies the usage of the technique and makes it easier to measure different kinds of specimens with different magnifications. However, the high flexibility of illumination and imaging also causes variable phase aberrations that need to be eliminated for high resolution quantitative phase imaging. The existent phase aberrations compensation methods either require add additional elements into the reference arm or need specimen free reference areas or separate reference holograms to build up suitable digital phase masks. These inherent requirements make them unpractical for usage with highly variable illumination and imaging systems and prevent on-line monitoring of living cells. In this paper, we present a simple numerical method for phase aberration compensation based on the analysis of holograms in spatial frequency domain with capabilities for on-line quantitative phase imaging. From a single shot off-axis hologram, the whole phase aberration can be eliminated automatically without numerical fitting or pre-knowledge of the setup. The capabilities and robustness for quantitative phase imaging of living cancer cells are demonstrated.

  15. Intactness of cell wall structure controls the in vitro digestion of starch in legumes.

    Science.gov (United States)

    Dhital, Sushil; Bhattarai, Rewati R; Gorham, John; Gidley, Michael J

    2016-03-01

    Increasing the level of starch that is not digested by the end of the small intestine and therefore enters the colon ('resistant starch') is a major opportunity for improving the nutritional profile of foods. One mechanism that has been shown to be successful is entrapment of starch within an intact plant tissue structure. However, the level of tissue intactness required for resistance to amylase digestion has not been defined. In this study, intact cells were isolated from a range of legumes after thermal treatment at 60 °C (starch not gelatinised) or 95 °C (starch gelatinised) followed by hydrolysis using pancreatic alpha amylase. It was found that intact cells, isolated at either temperature, were impervious to amylase. However, application of mechanical force damaged the cell wall and made starch accessible to digestive enzymes. This shows that the access of enzymes to the entrapped swollen starch is the rate limiting step controlling hydrolysis of starch in cooked legumes. The results suggest that a single cell wall could be sufficient to provide an effective delivery of starch to the large intestine with consequent nutritional benefits, provided that mechanical damage during digestion is avoided.

  16. SHOULD EVERY APPENDECECTOMY SPECIMEN BE SUBJECTED TO HISTOPATHOLOGICAL EXAMINATION? A RETROSPECTIVE STUDY OF HISTOLOGICAL FINDINGS IN APPENDICECTOMY SPECIMENS

    Directory of Open Access Journals (Sweden)

    Shahanuma Shaik

    2017-12-01

    Full Text Available BACKGROUND Appendicitis is one of the commonest surgical emergencies with a lifetime risk of 7-8%. The appendicectomy specimens operated upon clinically-suspected appendicitis often appear normal on gross examination, but histopathological evaluation may reveal a diverse underlying pathology. Therefore, for accurate diagnosis, histopathological examination of all appendicectomy specimens is mandatory. MATERIALS AND METHODS A retrospective study of 175 appendicectomy cases operated over a period of two years. The clinical data and histopathological reports were reviewed and various histopathological findings are categorised. RESULTS Out of the total 175 appendicectomies, 155 emergency appendicectomy cases were included in the study, while 20 cases of incidental appendicectomy were excluded. The peak incidence was found in the 2nd and 3rd decades with male predominance. Among the 155 specimens, 96.8% had histological features of appendicitis and 1.9% were normal appendix. The unusual histopathological findings were Carcinoid tumour and Enterobius vermicularis. CONCLUSION The definitive diagnoses of appendicitis as well as the unusual incidental findings that were missed intraoperatively are established by histopathological examination. The study supports the histological examination of all resected appendicectomy specimens.

  17. Differences in School Behavior and Achievement between Children from Intact, Reconstituted, and Single-Parent Families.

    Science.gov (United States)

    Featherstone, Darin R.; And Others

    1992-01-01

    Analyzed differences in school behavior and achievement among students (n=530) in grades six through nine from intact, reconstituted, and single-parent families. Students from intact, two-parent families had fewer absences and tardies, higher grade point averages, and fewer negative and more positive teacher behavioral ratings than did those from…

  18. Large area quantitative X-ray mapping of (U,Pu)O2 nuclear fuel pellets using wavelength dispersive electron probe microanalysis

    International Nuclear Information System (INIS)

    Bremier, S.; Haas, D.; Somers, J.; Walker, C.T.

    2003-01-01

    The work presented is an example of how large area compositional mapping (≥1 mm 2 ) can be used to provide quantitative information on element distribution and specimen homogeneity. High-resolution was accomplished by producing a collage of X-ray maps acquired using classical conditions; magnification x400, spatial resolution 256x256 pixels. The individual images, each measuring roughly 250x250 μm, were converted to quantitative maps using the HIMAX reg software package and the XMAS reg matrix correction from SAMx. The quantitative gray-level large area X-ray picture was pieced together using the 'Multiple Image Alignment' function of the ANALYSIS reg image processing software. This software was also used to convert the gray-level pictures to false color images. The specimens investigated were transverse sections of MOX fuel pellets. Results are presented for the distribution of Pu by area fraction and cumulative area fraction, the size distribution of regions of high Pu concentration and average separation of these regions

  19. Design and use of nonstandard tensile specimens for irradiated materials testing

    International Nuclear Information System (INIS)

    Panayotou, N.F.

    1984-10-01

    Miniature, nonstandard, tensile-type specimens have been developed for use in radiation effects experiments at high energy neutron sources where the useful radiation volume is as small as a few cubic centimeters. The end result of our development is a sheet-type specimen, 12.7 mm long with a 5.1 mm long, 1.0 mm wide gage section, which is typically fabricated from 0.25 mm thick sheet stock by a punching technique. Despite this miniature geometry, it has been determined that the data obtained using these miniature specimens are in good agreement with data obtained using much larger specimens. This finding indicates that miniature tensile specimen data may by used for engineering design purposes. Furthermore, it is clear that miniature tensile specimen technology is applicable to fields other than the study of radiation effects. This paper describes the miniature specimen technology which was developed and compares the data obtained from these miniature specimens to data obtained from much larger specimens. 9 figures

  20. Evaluation of the Behavior of Technova Corporation Rod-Stiffened Stitched Compression Specimens

    Science.gov (United States)

    Jegley, Dawn C.

    2013-01-01

    Under Space Act Agreement 1347 between NASA and Technova Corporation, Technova designed and fabricated two carbon-epoxy crippling specimens and NASA loaded them to failure in axial compression. Each specimen contained a pultruded rod stiffener which was held to the specimen skin with through-the-thickness stitches. One of these specimens was designed to be nominally the same as pultruded rod stitched specimens fabricated by Boeing under previous programs. In the other specimen, the rod was prestressed in a Technova manufacturing process to increase its ability to carrying compressive loading. Experimental results demonstrated that the specimen without prestressing carried approximately the same load as the similar Boeing specimens and that the specimen with prestressing carried significantly more load than the specimen without prestressing.

  1. Binding of radiolabelled luteinizing hormone to intact and ovariectomised rat uterus

    International Nuclear Information System (INIS)

    Sen, S.; Bhattacharya, S.

    1992-01-01

    Binding of ovine LH to uterine tissue preparation from intact and ovariectomised rat clearly indicates that uterus possesses specific binding sites for LH. Binding characteristics of LH to uterine tissue preparation from intact rat showed saturability with high affinity and low capacity. Scatchard plot analysis showed dissociation constant of the specific binding site to be 0.12 x 10 -9 mol/l and the number of binding sites was 2.31±0.05 fmol/mg protein. Ovariectomy did not change the binding affinity but effected a decrease in the number of binding sites (1.7 ± 0.08 f mol/mg protein). LH treatment of ovariectomized (ovx) rat had no effect on binding affinity but significantly increased the number of binding sites (3.23 ± 0.1 f mol/mg protein). Reduction of uterine weight due to ovariectomy and marked increase of ovx rat uterine weight by LH administration indicate a source of estrogen in ovx rat. An in vitro uterine tissue slice (from intact and ovx rat) incubation showed depletion of 17 β-estradiol (E 2 ) content in ovx rat which significantly elevated on LH addition. Data suggest the LH binding to rat uterine tissue has biological relevance. (author). 16 refs., 4 figs. 1 tab

  2. Preserve specimens for reproducibility

    Czech Academy of Sciences Publication Activity Database

    Krell, F.-T.; Klimeš, Petr; Rocha, L. A.; Fikáček, M.; Miller, S. E.

    2016-01-01

    Roč. 539, č. 7628 (2016), s. 168 ISSN 0028-0836 Institutional support: RVO:60077344 Keywords : reproducibility * specimen * biodiversity Subject RIV: EH - Ecology, Behaviour Impact factor: 40.137, year: 2016 http://www.nature.com/nature/journal/v539/n7628/full/539168b.html

  3. Quantitative Assessment of Orbital Implant Position--A Proof of Concept.

    Directory of Open Access Journals (Sweden)

    Ruud Schreurs

    Full Text Available In orbital reconstruction, the optimal location of a predefined implant can be planned preoperatively. Surgical results can be assessed intraoperatively or postoperatively. A novel method for quantifying orbital implant position is introduced. The method measures predictability of implant placement: transformation parameters between planned and resulting implant position are quantified.The method was tested on 3 human specimen heads. Computed Tomography scans were acquired at baseline with intact orbits (t0, after creation of the defect (t1 and postoperatively after reconstruction of the defect using a preformed implant (t2. Prior to reconstruction, the optimal implant position was planned on the t0 and t1 scans. Postoperatively, the planned and realized implant position were compared. The t0 and t2 scans were fused using iPlan software and the resulting implant was segmented in the fused t2 scan. An implant reference frame was created (Orbital Implant Positioning Frame; the planned implant was transformed to the reference position using an Iterative Closest Point approach. The segmentation of the resulting implant was also registered on the reference position, yielding rotational (pitch, yaw, roll as well as translational parameters of implant position.Measurement with the Orbital Implant Positioning Frame proved feasible on all three specimen. The positional outcome provided more thorough and accurate insight in resulting implant position than could be gathered from distance measurements alone. Observer-related errors were abolished from the process, since the method is largely automatic.A novel method of quantifying surgical outcome in orbital reconstructive surgery was presented. The presented Orbital Implant Positioning Frame assessed all parameters involved in implant displacement. The method proved to be viable on three human specimen heads. Clinically, the method could provide direct feedback intraoperatively and could improve

  4. Characterization of specimens obtained by different sampling methods for evaluation of periodontal bacteria.

    Science.gov (United States)

    Okada, Ayako; Sogabe, Kaoru; Takeuchi, Hiroaki; Okamoto, Masaaki; Nomura, Yoshiaki; Hanada, Nobuhiro

    2017-12-27

    Quantitative analysis of periodontal bacteria is considered useful for clinical diagnosis, evaluation and assessment of the risk of periodontal disease. The purpose of this study was to compare the effectiveness of sampling of saliva, supragingival and subgingival plaque for evaluation of periodontal bacteria. From each of 12 subjects, i) subgingival plaque was collected from the deepest pocket using a sterile paper point, ii) stimulated whole saliva was collected after chewing gum, and iii) supragingival plaque was collected using a tooth brush. These samples were sent to the medical examination laboratory for quantitative analysis of the counts of three periodontal bacterial species: Porphyromonas gingivalis, Treponema denticola, and Tannerella forsythia. The proportions of these bacteria in subgingival plaque were higher than those in saliva or supragingival plaque, but lower in subgingival plaque than in saliva or supragingival plaque. In several cases, periodontal bacteria were below the levels of detection in subgingival plaque. We concluded that samples taken from subgingival plaque may be more useful for evaluating the proportion of periodontal bacteria in deep pockets than is the case for other samples. Therefore, for evaluation of periodontal bacteria, clinicians should consider the characteristics of the specimens obtained using different sampling methods.

  5. Thermal expansion of epoxy-fiberglass composite specimens

    International Nuclear Information System (INIS)

    McElroy, D.L.; Weaver, F.J.; Bridgman, C.

    1986-01-01

    The thermal expansion behavior of three epoxy-fiberglass composite specimens was measured from 20 to 120 0 C (70 to 250 0 F) using a fused quartz push-rod dilatometer. Billets produced by vacuum impregnating layers of two types of fiberglass cloth with an epoxy resin were core-drilled to produce cylindrical specimens. These were used to study expansion perpendicular and parallel to the fiberglass layers. The dilatometer is held at a preselected temperature until steady-state is indicated by stable length and temperature data. Before testing the composite specimens, a reliability check of the dilatometer was performed using a copper secondary standard. This indicated thermal expansion coefficient (α) values within +-2% of expected values from 20 to 200 0 C

  6. Modelling of the deformation of shot peened cylindrical specimens of 42 CrMo4 in uniaxial tension and deformation and of the resulting macro residual stresses

    International Nuclear Information System (INIS)

    Schulze, V.; Voehringer, O.; Macherauch, E.

    1998-01-01

    Tensile and compressive stress-strain-curves of shot peened and unpeened specimens of quenched and tempered 42 CrMo 4 (AISI 4140) with a diameter of 5 mm only differ in the yield strengths and in the Lueders-deformation. In comparison to the core the regions close to the surface of shot peened cylindrical specimens bear relatively large axial and tangential residual stresses and show different deformation properties. A multi-layer-model was developed to describe both the tensile as well as the compressive deformation behaviour of shot peened cylindrical specimens quantitatively. The calculated transitions from the elastic to the elastic-plastic deformation state during tensile and compressive loading agree quite well with the experimental observations. Also the changes of axial and tangential macro residual stresses after distinct tensile or compressive deformations are in best agreement with the measurements. (orig.)

  7. Risks for Conduct Disorder Symptoms Associated with Parental Alcoholism in Stepfather Families versus Intact Families from a Community Sample

    Science.gov (United States)

    Foley, Debra L.; Pickles, Andrew; Rutter, Michael; Gardner, Charles O.; Maes, Hermine H.; Silberg, Judy L.; Eaves, Lindon J.

    2004-01-01

    Background: It is not known if the prevalence of parental psychiatric disorders is higher in stepfather than intact families, or if parental alcoholism is differentially associated with risk for conduct disorder (CD) symptoms in stepfather families versus intact families. Method: The sample comprised 839 girls and 741 boys from 792 intact families…

  8. Behavior Management Style of Single Parents and Intact Families.

    Science.gov (United States)

    Smith, Douglas K.; And Others

    Studies examining the behavior management styles of parents as a function of family intactness and parent employment status are lacking. To assess parental style of behavior management, the Parental Management Questionnaire (PMQ) was completed by 1,957 parents of elementary school children (50% response rate). The PMQ is based on Aronfreed's…

  9. Biaxial Creep Specimen Fabrication

    Energy Technology Data Exchange (ETDEWEB)

    JL Bump; RF Luther

    2006-02-09

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments.

  10. Biaxial Creep Specimen Fabrication

    International Nuclear Information System (INIS)

    JL Bump; RF Luther

    2006-01-01

    This report documents the results of the weld development and abbreviated weld qualification efforts performed by Pacific Northwest National Laboratory (PNNL) for refractory metal and superalloy biaxial creep specimens. Biaxial creep specimens were to be assembled, electron beam welded, laser-seal welded, and pressurized at PNNL for both in-pile (JOYO reactor, O-arai, Japan) and out-of-pile creep testing. The objective of this test campaign was to evaluate the creep behavior of primary cladding and structural alloys under consideration for the Prometheus space reactor. PNNL successfully developed electron beam weld parameters for six of these materials prior to the termination of the Naval Reactors program effort to deliver a space reactor for Project Prometheus. These materials were FS-85, ASTAR-811C, T-111, Alloy 617, Haynes 230, and Nirnonic PE16. Early termination of the NR space program precluded the development of laser welding parameters for post-pressurization seal weldments

  11. Corrosive and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy.

    Science.gov (United States)

    Ristic, Ljubisa; Vucevic, Dragana; Radovic, Ljubica; Djordjevic, Snezana; Nikacevic, Milutin; Colic, Miodrag

    2014-04-01

    Nickel-chromium (Ni-Cr) dental alloys have been widely used in prosthodontic practice, but there is a permanent concern about their biocompatibility due to the release of metal ions. This is especially important when Ni-Cr metal microparticles are incorporated into gingival tissue during prosthodontic procedures. Therefore, the aim of this study was to examine and compare the corrosion and cytotoxic properties of compact specimens and microparticles of Ni-Cr dental alloy. Ni-Cr alloy, Remanium CSe bars (4 mm diameter), were made by the standard casting method and then cut into 0.5-mm-thick disks. Metal particles were obtained by scraping the bars using a diamond instrument for crown preparation. The microstructure was observed by an optical microscope. Quantitative determination and morphological and dimensional characterization of metal particles were carried out by a scanning electron microscope and Leica Application Suite software for image analysis. Corrosion was studied by conditioning the alloy specimens in the RPMI 1640 medium, containing 10% fetal calf serum in an incubator with 5% CO2 for 72 hours at 37°C. Inductively coupled plasma-optical emission spectrometry was used to assess metal ion release. The cytotoxity of conditioning medium (CM) was investigated on L929 cells using an MTT test. One-way ANOVA was used for statistical analysis. After casting, the microstructure of the Remanium CSe compact specimen composed of Ni, Cr, Mo, Si, Fe, Al, and Co had a typical dendritic structure. Alloy microparticles had an irregular shape with a wide size range: from less than 1 μm to more than 100 μm. The release of metal ions, especially Ni and Mo from microparticles, was significantly higher, compared to the compact alloy specimen. The CM prepared from compact alloy was not cytotoxic at any tested dilutions, whereas CM from alloy microparticles showed dose-dependent cytotoxicity (90% CM and 45% CM versus control; p alloy. This could affect health on long

  12. Contribution of flow cytometry to the diagnosis of gastric lymphomas in endoscopic biopsy specimens.

    Science.gov (United States)

    Almasri, N M; Zaer, F S; Iturraspe, J A; Braylan, R C

    1997-07-01

    Gastric lymphomas seem to have unique clinical, pathologic, and immunophenotypic features that set them apart from nodal lymphomas. Microscopic examination of endoscopic biopsy specimens is the most frequent procedure used to diagnose gastric tumors, but it is very difficult, and sometimes impossible, to recognize lymphomas in endoscopic samples by histologic or even immunohistologic methods. Because most gastric lymphomas are of B-cell origin, we used flow cytometry to assess B-cell clonality in gastric biopsy specimens containing dense lymphocytic infiltrates thought to represent lymphoma. We prepared viable cell suspensions from unfixed specimens obtained from 29 consecutive patients who had a previous microscopic diagnosis of suspicious gastric lymphoid infiltrates. We performed immunophenotypic studies with multicolor flow cytometry, and we assessed clonality by examination of immunoglobulin (Ig) light-chain expression analyzed exclusively on B cells identified by anti-CD20 or CD19 antibodies. The mean number of cells recovered was 1.04 x 10(6), from an average of 5.5 gastric biopsy fragments per patient. In 26 of the 29 patients, the number of cells was adequate for analysis. We detected B-cell monoclonality in 16 cases, including 5 in which the percentage of clonal B cells was less than 5%. Of the 16 cases, only 8 could be diagnosed as lymphomas on morphologic grounds alone; the remaining 8 patients had either suspicious lymphoid infiltrates or chronic gastritis. The three cases with an insufficient number of cells were considered non-neoplastic either on histologic grounds alone or in conjunction with Southern analysis of Ig genes. We conclude that flow cytometric immunophenotypic analysis of freshly prepared cell suspensions obtained from endoscopic biopsy specimens can be used to evaluate gastric lymphocytic infiltrates. Specifically, the analysis of surface Ig light-chain expression on B cells distinguishes between monoclonal (lymphoma) and polyclonal

  13. Comparison of allergenicity and immunogenicity of an intact allergen vaccine and commercially available allergoid products for birch pollen immunotherapy.

    Science.gov (United States)

    Lund, L; Henmar, H; Würtzen, P A; Lund, G; Hjortskov, N; Larsen, J N

    2007-04-01

    Specific immunotherapy with intact allergen vaccine is a well-documented treatment for allergic diseases. Different vaccine formulations are currently commercially available, the active ingredient either being intact allergens or chemically modified allergoids. The rationale behind allergoids is to decrease allergenicity while maintaining immunogenicity. However, data from the German health authorities based on reporting of adverse events over a 10-year period did not indicate increased safety of allergoids over intact allergens. The objective of this study was to investigate the effect of chemical modification on allergenicity and immunogenicity comparing four commercial allergoid products for birch pollen immunotherapy with an intact allergen vaccine. Solid-phase IgE inhibition and histamine release assays were selected as model systems for allergenicity, and a combination of human T cell proliferation and IgG titres following mouse immunizations were used to address the immunogenicity of the intact allergen vaccine and the four allergoids. In all assays, the products were normalized with respect to the manufacturer's recommended maintenance dose. IgE inhibition experiments showed a change in epitope composition comparing intact allergen vaccine with allergoid. One allergoid product induced enhanced histamine release compared to the intact allergens, while the other three allergoids showed reduced release. Standard T cell stimulation assays using lines from allergic patients showed a reduced response for all allergoids compared with the intact allergen vaccine regardless of the cell type used for antigen presentation. All allergoids showed reduced capacity to induce allergen-specific IgG responses in mice. While some allergoids were associated with reduced allergenicity, a clear reduction in immunogenicity was observed for all allergoid products compared with the intact allergen vaccine, and the commercial allergoids tested therefore do not fulfil the allergoid

  14. Raman spectroscopy of normal oral buccal mucosa tissues: study on intact and incised biopsies

    Science.gov (United States)

    Deshmukh, Atul; Singh, S. P.; Chaturvedi, Pankaj; Krishna, C. Murali

    2011-12-01

    Oral squamous cell carcinoma is one of among the top 10 malignancies. Optical spectroscopy, including Raman, is being actively pursued as alternative/adjunct for cancer diagnosis. Earlier studies have demonstrated the feasibility of classifying normal, premalignant, and malignant oral ex vivo tissues. Spectral features showed predominance of lipids and proteins in normal and cancer conditions, respectively, which were attributed to membrane lipids and surface proteins. In view of recent developments in deep tissue Raman spectroscopy, we have recorded Raman spectra from superior and inferior surfaces of 10 normal oral tissues on intact, as well as incised, biopsies after separation of epithelium from connective tissue. Spectral variations and similarities among different groups were explored by unsupervised (principal component analysis) and supervised (linear discriminant analysis, factorial discriminant analysis) methodologies. Clusters of spectra from superior and inferior surfaces of intact tissues show a high overlap; whereas spectra from separated epithelium and connective tissue sections yielded clear clusters, though they also overlap on clusters of intact tissues. Spectra of all four groups of normal tissues gave exclusive clusters when tested against malignant spectra. Thus, this study demonstrates that spectra recorded from the superior surface of an intact tissue may have contributions from deeper layers but has no bearing from the classification of a malignant tissues point of view.

  15. Rehydration of forensically important larval Diptera specimens.

    Science.gov (United States)

    Sanford, Michelle R; Pechal, Jennifer L; Tomberlin, Jeffery K

    2011-01-01

    Established procedures for collecting and preserving evidence are essential for all forensic disciplines to be accepted in court and by the forensic community at large. Entomological evidence, such as Diptera larvae, are primarily preserved in ethanol, which can evaporate over time, resulting in the dehydration of specimens. In this study, methods used for rehydrating specimens were compared. The changes in larval specimens with respect to larval length and weight for three forensically important blow fly (Diptera: Calliphoridae) species in North America were quantified. Phormia regina (Meigen), Cochliomyia macellaria (F.), and Chrysomya rufifacies (Macquart) third-instar larvae were collected from various decomposing animals and preserved with three preservation methods (80% ethanol, 70% isopropyl alcohol, and hot-water kill then 80% ethanol). Preservative solutions were allowed to evaporate. Rehydration was attempted with either of the following: 80% ethanol, commercial trisodium phosphate substitute solution, or 0.5% trisodium phosphate solution. All three methods partially restored weight and length of specimens recorded before preservation. Analysis of variance results indicated that effects of preservation, rehydration treatment, and collection animal were different in each species. The interaction between preservative method and rehydration treatment had a significant effect on both P. regina and C. macellaria larval length and weight. In addition, there was a significant interaction effect of collection animal on larval C. macellaria measurements. No significant effect was observed in C. rufifacies larval length or weight among the preservatives or treatments. These methods could be used to establish a standard operating procedure for dealing with dehydrated larval specimens in forensic investigations.

  16. Secretion of intact proteins and peptide fragments by lysosomal pathways of protein degradation

    International Nuclear Information System (INIS)

    Isenman, L.D.; Dice, J.F.

    1989-01-01

    We report that degradation of proteins microinjected into human fibroblasts is accompanied by release into the culture medium of peptide fragments and intact proteins as well as single amino acids. For the nine proteins and polypeptides microinjected, acid-precipitable radioactivity, i.e. peptide fragments and/or intact proteins, ranged from 10 to 67% of the total released radioactivity. Peptide fragments and/or intact protein accounted for 60% of the radioactivity released into the medium by cells microinjected with ribonuclease A. Two major radiolabeled peptide fragments were found, and one was of an appropriate size to function as an antigen in antigen-presenting cells. The peptides released from microinjected ribonuclease A were derived from lysosomal pathways of proteolysis based on several lines of evidence. Previous studies have shown that microinjected ribonuclease A is degraded to single amino acids entirely within lysosomes. We show that release of free amino acids and peptide fragments and/or intact protein was equivalently stimulated by serum deprivation and equivalently inhibited by NH4Cl. We also show that lysosomal degradation of endocytosed [3H]ribonuclease A was accompanied by the release of two peptide fragments similar in size and charge to those from microinjected [ 3 H]ribonuclease A. These findings demonstrate that degradation within lysosomes occurs in a manner that spares specific peptides; they also suggest a previously unsuspected pathway by which cells can secrete cytosol-derived polypeptides

  17. Demonstration of Laser Cutting System for Tube Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Kim, G. S.; Heo, G. S.; Baik, S. J.; Kim, H. M.; Ahn, S. B. [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated fuel cladding and components interrupted the applying the electric current during the processing. However, it was found that the mechanical testing data of the irradiated specimens with removal of oxide layer was less reliable than the specimens with oxide layer . The laser cutting system using Nd:YAG with fiber optic beam delivery has great potential in material processing applications of the irradiated fuel cladding and components due to non-contact process. Thus, the oxide layer doesn't interrupt the fabrication process during the laser cutting system. In the present study, the laser cutting system was designed to fabricate the mechanical testing specimens from the unirradiated fuel cladding with and without oxide. The feasibility of the laser cutting system was demonstrated for the fabrication of various types of unirradiated specimens. The effect of surface oxide layer was also investigated for machining process of the zirlo fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer. Based on the feasibility studies and demonstration, the design of the laser cutting machine for fully or partially automatic and remotely operable system will be proposed and made.

  18. 40 CFR 261.40 - Conditional Exclusion for Used, Intact Cathode Ray Tubes (CRTs) Exported for Recycling.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 25 2010-07-01 2010-07-01 false Conditional Exclusion for Used, Intact Cathode Ray Tubes (CRTs) Exported for Recycling. 261.40 Section 261.40 Protection of Environment...) Exported for Recycling. Used, intact CRTs exported for recycling are not solid wastes if they meet the...

  19. Radioimmunolocalization and selective delivery of radiation in a rat model system: comparison of intact and fragmented antibody

    International Nuclear Information System (INIS)

    Walker, K.Z.; Seymour-Munn, K.; Axiak, S.M.; Raison, R.L.; Basten, A.; Towson, J.E.; Bautovitch, G.J.; Morris, J.

    1988-01-01

    Monoclonal antibody (MoAb) fragments are known to have advantages over intact immunoglobulins for radioimmunoscintigraphy. It is less clear whether they are as effective in the delivery of radioimmunotherapy. The imaging and dosimetric properties of an intact MoAb, K-1-21, reactive against human kappa light chains (LC) were compared with that of its F(ab') 2 and Fab fragments using a normal rat model system. Two days after injection of 131 I-K-1-21 into rats bearing antigen-sepharose implants, gamma camera images showed specific localization of the MoAb to the target (kappa LC) but not to the control (lambda LC) implant. Better images were obtained with K-1-21 F(ab') 2 than with Fab or intact antibody. Mean kappa implant: blood ratios were 8.6 ± 3.9 for Fab, 7.9 ± 1.8 for F(ab') 2 and 2.0 ± 0.3 for intact K-1-21. The improvement associated with the use of 131 I-K-1-21 fragments was, however, achieved at the expense of lower absolute values of activity at the target site. Thus the absorbed dose delivered to the implant by the intact K-1-21 was double that delivered with F(ab') 2 and six times that delivered with Fab. As intact K-1-21 also delivered a greater radiation dose to normal tissues, F(ab') 2 fragments may have the greatest overall advantages for therapy with radionuclide MoAb conjugates. (author)

  20. Oxidation of molecular tritium by intact soils

    International Nuclear Information System (INIS)

    Sweet, C.W.; Murphy, C.E. Jr.

    1980-01-01

    The effects of environmental factors on the rate of oxidation of molecular tritium (T 2 ) to tritiated water (HTO) were determined for intact soils during field exposures. Maximum deposition velocities of approximately 0.03 cm/sec were measured for T 2 at low wind speeds for a variety of soils over a wide range of conditions. Deposition velocities were slightly inhibited in wet soils and at 0 0 C. In dry soils, oxidation of T 2 to HTO occurred deeper in the soil profile, but deposition velocities were unaffected

  1. Decomposition of intact chicken feathers by a thermophile in combination with an acidulocomposting garbage-treatment process.

    Science.gov (United States)

    Shigeri, Yasushi; Matsui, Tatsunobu; Watanabe, Kunihiko

    2009-11-01

    In order to develop a practical method for the decomposition of intact chicken feathers, a moderate thermophile strain, Meiothermus ruber H328, having strong keratinolytic activity, was used in a bio-type garbage-treatment machine working with an acidulocomposting process. The addition of strain H328 cells (15 g) combined with acidulocomposting in the garbage machine resulted in 70% degradation of intact chicken feathers (30 g) within 14 d. This degradation efficiency is comparable to a previous result employing the strain as a single bacterium in flask culture, and it indicates that strain H328 can promote intact feather degradation activity in a garbage machine currently on the market.

  2. Molecular markers: Implications for cytopathology and specimen collection.

    Science.gov (United States)

    VanderLaan, Paul A

    2015-08-01

    Cytologic specimens obtained through minimally invasive biopsy techniques are increasingly being used as principle diagnostic specimens for tumors arising in multiple sites. The number and scope of ancillary tests performed on these specimens have grown substantially over the past decade, including many molecular markers that not only can aid in formulating accurate and specific diagnoses but also can provide prognostic or therapeutic information to help direct clinical decisions. Thus, the cytopathologist needs to ensure that adequate material is collected and appropriately processed for the study of relevant molecular markers, many of which are specific to tumor site. This brief review covers considerations for effective cytologic specimen collection and processing to ensure diagnostic and testing success. In addition, a general overview is provided of molecular markers pertinent to tumors from a variety of sites. The recognition of these established and emerging molecular markers by cytopathologists is an important step toward realizing the promise of personalized medicine. © 2015 American Cancer Society.

  3. Detection of metabolites of lysergic acid diethylamide (LSD) in human urine specimens: 2-oxo-3-hydroxy-LSD, a prevalent metabolite of LSD.

    Science.gov (United States)

    Poch, G K; Klette, K L; Hallare, D A; Manglicmot, M G; Czarny, R J; McWhorter, L K; Anderson, C J

    1999-03-05

    Seventy-four urine specimens previously found to contain lysergic acid diethylamide (LSD) by gas chromatography-mass spectrometry (GC-MS) were analyzed by a new procedure for the LSD metabolite 2-oxo-3-hydroxy-LSD (O-H-LSD) using a Finnigan LC-MS-MS system. This procedure proved to be less complex, shorter to perform and provides cleaner chromatographic characteristics than the method currently utilized by the Navy Drug Screening Laboratories for the extraction of LSD from urine by GC-MS. All of the specimens used in the study screened positive for LSD by radioimmunoassay (Roche Abuscreen). Analysis by GC-MS revealed detectable amounts of LSD in all of the specimens. In addition, isolysergic diethylamide (iso-LSD), a byproduct of LSD synthesis, was quantitated in 64 of the specimens. Utilizing the new LC-MS-MS method, low levels of N-desmethyl-LSD (nor-LSD), another identified LSD metabolite, were detected in some of the specimens. However, all 74 specimens contained O-H-LSD at significantly higher concentrations than LSD, iso-LSD, or nor-LSD alone. The O-H-LSD concentration ranged from 732 to 112 831 pg/ml (mean, 16340 pg/ml) by quantification with an internal standard. The ratio of O-H-LSD to LSD ranged from 1.1 to 778.1 (mean, 42.9). The presence of O-H-LSD at substantially higher concentrations than LSD suggests that the analysis for O-H-LSD as the target analyte by employing LC-MS-MS will provide a much longer window of detection for the use of LSD than the analysis of the parent compound, LSD.

  4. Laboratory specimens and genetic privacy: evolution of legal theory.

    Science.gov (United States)

    Lewis, Michelle Huckaby

    2013-03-01

    Although laboratory specimens are an important resource for biomedical research, controversy has arisen when research has been conducted without the knowledge or consent of the individuals who were the source of the specimens. This paper summarizes the most important litigation regarding the research use of laboratory specimens and traces the evolution of legal theory from property claims to claims related to genetic privacy interests. © 2013 American Society of Law, Medicine & Ethics, Inc.

  5. 50 CFR 31.11 - Donation and loan of wildlife specimens.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Donation and loan of wildlife specimens... of Wildlife Reduction and Disposal § 31.11 Donation and loan of wildlife specimens. Wildlife specimens may be donated or loaned to public institutions for specific purposes. Donation or loans of...

  6. Instrumented impact testing machine with reduced specimen oscillation effects

    International Nuclear Information System (INIS)

    Rintamaa, R.; Rahka, K.; Wallin, K.

    1984-07-01

    Owing to small and inexpensive specimens the Charpy impact test is widely used in quality control and alloy development. Limitations in power reactor survellance capsules it is also widely used for safety analysis purposes. Instrumenting the tup and computerizing data acquisition, makes dynamic fracture mechanics data measurement possible and convenient. However, the dynamic effects (inertia forces, specimen oscillations) in the impact test cause inaccuracies in the recorded load-time diagram and hence diminish the reliability of the calculated dynamic fracture mechanics parameters. To decrease inaccuracies a new pendulum type of instrumented impact test apparatus has been developed and constructed in the Metals Laboratory of the Technical Research Centre of Finland. This tester is based on a new principle involving inverted test geometry. The purpose of the geometry inversion is to reduce inertia load and specimen oscillation effects. Further, the new impact tester has some other novel features: e.g. the available initia impact energy is about double compared to the conventional standard (300 J) impact tester allowing the use of larger (10 x 20 x 110 mm) bend specimens than normal Charpy specimens. Also, the rotation asix in the three point bending is nearly stationary making COD-measurements possible. An experimental test series is described in which the inertia effects and specimen oscillations are compared in the conventional and new impact tester utilizing Charpy V-notch specimens. Comparison of the two test geometries is also made with the aid of an analytical model using finite element method (FEM) analysis. (author)

  7. Drone Transport of Microbes in Blood and Sputum Laboratory Specimens.

    Science.gov (United States)

    Amukele, Timothy K; Street, Jeff; Carroll, Karen; Miller, Heather; Zhang, Sean X

    2016-10-01

    Unmanned aerial vehicles (UAVs) could potentially be used to transport microbiological specimens. To examine the impact of UAVs on microbiological specimens, blood and sputum culture specimens were seeded with usual pathogens and flown in a UAV for 30 ± 2 min. Times to recovery, colony counts, morphologies, and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS)-based identifications of the flown and stationary specimens were similar for all microbes studied. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  8. Prevalence of depressive symptoms in older nursing home residents with intact cognitive function in Taiwan.

    Science.gov (United States)

    Hu, Sophia H; Chuang, Yeu-Hui; Ting, Yeh-Feng; Lin, Kuan-Yu; Hsieh, Chia-Jung

    2018-03-25

    The investigators aimed to explore the prevalence of depressive symptoms and associated factors among older residents with intact cognitive function in nursing homes in Taiwan. A cross-sectional descriptive and correlational research design was used. A convenience sample of 178 older residents without cognitive impairment was recruited from 36 nursing homes in Southern Taiwan. The questionnaires included demographic data; the Barthel Index, which assesses the ability to perform activities of daily living; and the Geriatric Depression Scale Short Form. Among older residents in nursing homes with intact cognitive function, 39.3% had depressive symptoms. Age, religion, previous living status, previous working status, being totally dependent in physical function, and being severely dependent in physical function were significant predictors of depressive symptoms among cognitively intact older residents. The findings highlight the critical mental healthcare issues among older residents with intact cognitive function in nursing homes. Practical strategies for preventing the occurrence of depressive symptoms and caring for those who have depressive symptoms should be developed, especially for younger or dependent older residents or residents who have never been employed, have no religious beliefs, or have lived alone before they moved into an institution. © 2018 Wiley Periodicals, Inc.

  9. Preliminary investigations into macroscopic attenuated total reflection-fourier transform infrared imaging of intact spherical domains: spatial resolution and image distortion.

    Science.gov (United States)

    Everall, Neil J; Priestnall, Ian M; Clarke, Fiona; Jayes, Linda; Poulter, Graham; Coombs, David; George, Michael W

    2009-03-01

    This paper describes preliminary investigations into the spatial resolution of macro attenuated total reflection (ATR) Fourier transform infrared (FT-IR) imaging and the distortions that arise when imaging intact, convex domains, using spheres as an extreme example. The competing effects of shallow evanescent wave penetration and blurring due to finite spatial resolution meant that spheres within the range 20-140 microm all appeared to be approximately the same size ( approximately 30-35 microm) when imaged with a numerical aperture (NA) of approximately 0.2. A very simple model was developed that predicted this extreme insensitivity to particle size. On the basis of these studies, it is anticipated that ATR imaging at this NA will be insensitive to the size of intact highly convex objects. A higher numerical aperture device should give a better estimate of the size of small spheres, owing to superior spatial resolution, but large spheres should still appear undersized due to the shallow sampling depth. An estimate of the point spread function (PSF) was required in order to develop and apply the model. The PSF was measured by imaging a sharp interface; assuming an Airy profile, the PSF width (distance from central maximum to first minimum) was estimated to be approximately 20 and 30 microm for IR bands at 1600 and 1000 cm(-1), respectively. This work has two significant limitations. First, underestimation of domain size only arises when imaging intact convex objects; if surfaces are prepared that randomly and representatively section through domains, the images can be analyzed to calculate parameters such as domain size, area, and volume. Second, the model ignores reflection and refraction and assumes weak absorption; hence, the predicted intensity profiles are not expected to be accurate; they merely give a rough estimate of the apparent sphere size. Much further work is required to place the field of quantitative ATR-FT-IR imaging on a sound basis.

  10. Genistein Stimulates Jejunum Chloride Secretion via an Akt-Mediated Pathway in Intact Female Mice

    Directory of Open Access Journals (Sweden)

    Lana Leung

    2015-02-01

    Full Text Available Background/Aims: We have previously shown that daily subcutaneous injections with the naturally occurring phytoestrogen genistein (600 mg genistein/kg body weight/day, 600G results in a significantly increased basal intestinal chloride, Cl-, secretion (Isc, a measure of transepithelial secretion in intact C57BL/6J female mice after 1-week of treatment, compared to controls (DMSO vehicle injected. Removal of endogenous estrogen via ovariectomy (OVX had no effect on the 600G-mediated increase in basal Isc. Methods: Given the estrogen-like characteristics of genistein, we compared the effects of daily estradiol (E2 injections (10 mg E2/kg body weight/day, 10E2 on basal Isc in intact and OVX mice. In intact mice, 10E2 was without effect on basal Isc, however, in OVX mice, 10E2 significantly increased basal Isc (mimicked 600G. The goal of the current study was to characterize the intracellular signaling pathways responsible for mediating 600G- or 10E2-stimulated increases in basal Isc in intact female or OVX mice. Results: We measured total protein expression in isolated segments of jejunum using western blot from the following six groups of mice; intact or OVX with; 600G, 10E2 or control. The proteins of interest were: Akt, p-Akt, p-PDK1, p-PTEN, p-c-Raf, p-GSK-3β, rap-1 and ERK1/2. All blots were normalized to GAPDH levels (n = 6-18/group. Conclusion: These data suggest that the presence of the endogenous sex steroid, estrogen, modifies the intracellular signaling pathway required to mediate Cl- secretion when the intestine is exposed to exogenous 600G or E2. These studies may have relevance for designing pharmacological tools for women with intestinal chloride secretory dysfunctions.

  11. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    International Nuclear Information System (INIS)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B.

    2015-01-01

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer

  12. Feasibility Study of Laser Cutting for Fabrication of Tensile Specimen

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Y. G.; Baik, S. J.; Kim, G. S.; Heo, G. S.; Yoo, B. O.; Ahn, S. B.; Chun, Y. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    The specimen fabrication technique was established to machine the specimen from the irradiated materials. The wire cut EDM(electric discharge machine) was modified to fabricate the mechanical testing specimens from irradiated components and fuel claddings. The oxide layer removal system was also developed because the oxide layer on the surface of the irradiated components and claddings interrupted the applying the electric current during the processing. However, zirconium oxide is protective against further corrosion as well as beneficial to mechanical strength for the tensile deformation of the cladding. Thus, it is important to fabricate the irradiated specimens without removal of oxide layer on the surface of the irradiated structural components and claddings. In the present study, laser cutting system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the feasibility of the laser cutting system was studied for the fabrication of various types of irradiated specimens in a hot cell at IMEF (Irradiated Materials Examination Facility) of KAERI. Laser beam machining system was introduced to fabricate the various mechanical testing specimens from the unirradiated fuel cladding and the dimensions were compared for the feasibility of the laser cutting system. The effect of surface oxide layer was also investigated for machining process of the zircaloy-4 fuel cladding and it was found that laser beam machining could be a useful tool to fabricate the specimens with surface oxide layer.

  13. Validity of fracture toughness determined with small bend specimens

    International Nuclear Information System (INIS)

    Wallin, K.; Rintamaa, R.; Valo, M.

    1994-02-01

    This report considers the validity of fracture toughness estimates obtained with small bend specimens in relation to fracture toughness estimates obtained with large specimens. The study is based upon the analysis and comparison of actual test results. The results prove the validity of the fracture toughness determined based upon small bend specimens, especially when the results are only used to determine the fracture toughness transition temperature T o . In this case the possible error is typically less than 5 deg C and at most 10 deg C. It can be concluded that small bend specimens are very suitable for the estimation of fracture toughness in the case of brittle fracture, provided the results are corrected for statistical size effects. (orig.). (20 refs., 17 figs.)

  14. A new standardless quantitative electron probe microanalysis technique applied to III-V compound semiconductors

    International Nuclear Information System (INIS)

    Zangalis, K.P.; Christou, A.

    1982-01-01

    The present paper introduces a new standardless quantitative scheme for off-line electron microprobe analysis applications. The analysis is based on standard equations of the type Isub(i)=Csub(i)fsub(ZAF)βsub(i) and is specifically suitable for compound semiconductors. The roots to the resultant nth-degree polynomial are the unknown concentrations. Methods for computing Csub(i) when coefficients βsub(i) are unknown are also outlined. Applications of standardless analysis to GaAs and InP specimens are compared with results obtained by Auger electron spectroscopy and quantitative electron probe analysis with standards. (Auth.)

  15. 46 CFR 173.025 - Additional intact stability standards: Counterballasted vessels.

    Science.gov (United States)

    2010-10-01

    ...) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSEL USE Lifting § 173.025 Additional intact stability standards: Counterballasted vessels. (a) Each vessel equipped to counterballast while lifting must be shown... loading and operation and at each combination of hook load and crane radius. (b) When doing the...

  16. SurePath Specimens Versus ThinPrep Specimen Types on the COBAS 4800 Platform: High-Risk HPV Status and Cytology Correlation in an Ethnically Diverse Bronx Population.

    Science.gov (United States)

    Naeem, R C; Goldstein, D Y; Einstein, Mark H; Ramos Rivera, G; Schlesinger, K; Khader, S N; Suhrland, M; Fox, A S

    2017-08-01

    To compare the cytologic preparations of 130 cervical specimens (from women of various ethnicities at high risk for human papillomavirus [HPV] infection) using the SurePath (SP) collection system with specimens gathered using the ThinPrep (TP) system, as processed on the Cobas 4800 analyzer, to determine which collection method more accurately identifies HPV infection. In our prospective study, specimens were collected from 130 women of various ethnicities residing in or near Bronx County, NY. The SP-collected specimen was first processed for cytologic findings; if clinical HPV testing was requested on that specimen, it was tested using Hybrid Capture II (HC2) methodology. We tested the remnant SP-collected cell concentrate using the Cobas analyzer. Then, the TP-collected and SP-collected specimens were tested in the same run on that analyzer, and the results were compared. We also compared the results with the concurrent cytologic findings. The results were concordant for overall HR-HPV status in 93.8% of cases. Also, a statistically significant lower cycle threshold value was observed with Cobas testing of specimen concentrates tested via the BD SurePath Pap Test (P = .001), suggesting higher sensitivity compared with specimens tested via the ThinPrep Pap Test. Cobas 4800 HPV testing of SP-collected specimen concentrates yields comparable results to TP-collected specimen concentrates. Based on the limited data that we derived, SP collection may be a more favorable methodology than TP collection for HPV testing of individuals at high risk in our ethnically diverse, urban patient population. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  17. In vitro permeation of palladium powders through intact and damaged human skin.

    Science.gov (United States)

    Crosera, Matteo; Mauro, Marcella; Bovenzi, Massimo; Adami, Gianpiero; Baracchini, Elena; Maina, Giovanni; Larese Filon, Francesca

    2018-05-01

    The use of palladium (Pd) has grown in the last decades, commonly used in automotive catalytic converters, jewellery and dental restorations sectors. Both general and working population can be exposed to this metal, which may act as skin sensitizer. This study investigated in vitro palladium powders permeation through excised intact and damaged human skin using the Franz diffusion cell method and the effect of rapid skin decontamination using sodium laureth-sulphate. 1 mL of a 10 min sonicated suspension made of 2.5 g of Pd powder in 50 mL synthetic sweat at pH 4.5 and room temperature was applied to the outer surface of the skin membranes for 24 h. Pd permeation, assessed by ICP-MS, was higher when damaged skin was used (p = 0.03). Final flux permeation values and lag times were 0.02 ± 0.01 μg cm -2  h -1 and 6.00 ± 3.95 h for intact, and 0.10 ± 0.02 μg cm -2  h -1 and 2.05 ± 1.49 h for damaged skin samples, respectively. Damaged skin protocol enhances Pd skin penetration inside dermal layer (p = 0.04), thus making the metal available for systemic uptake. Pd penetration (p = 0.02) and permeation (p = 0.012) through intact skin decreased significantly when a cleaning procedure was applied. This study demonstrates that after skin exposure to Pd powders a small permeation of the metal happen both through intact and damaged skin and that an early decontamination with a common cleanser can significantly decrease the final amount of metal available forsystemic uptake. Copyright © 2018 Elsevier B.V. All rights reserved.

  18. IgE epitopes of intact and digested Ara h 1

    DEFF Research Database (Denmark)

    Bøgh, Katrine Lindholm; Nielsen, H.; Madsen, Charlotte Bernhard

    2012-01-01

    epitopes have been suggested to be of great importance. ObjectiveThe aim of this study was to identify IgE specific epitopes of intact and digested Ara h 1, and to compare epitope patterns between humans and rats. MethodsSera from five peanut allergic patients and five Brown Norway rats were used...... to identify intact and digested Ara h 1-specific IgE epitopes by competitive immunoscreening of a phage-displayed random hepta-mer peptide library using polyclonal IgE from the individual sera. The resulting peptide sequences were mapped on the surface of a three-dimensional structure of the Ara h 1 molecule...... to mimic epitopes using a computer-based algorithm. ResultsPatients as well as rats were shown to have individual IgE epitope patterns. All epitope mimics were conformational and found to cluster into three different areas of the Ara h 1 molecule. Five epitope motifs were identified by patient IgE, which...

  19. NASA Biological Specimen Repository

    Science.gov (United States)

    McMonigal, K. A.; Pietrzyk, R. A.; Sams, C. F.; Johnson, M. A.

    2010-01-01

    The NASA Biological Specimen Repository (NBSR) was established in 2006 to collect, process, preserve and distribute spaceflight-related biological specimens from long duration ISS astronauts. This repository provides unique opportunities to study longitudinal changes in human physiology spanning may missions. The NBSR collects blood and urine samples from all participating ISS crewmembers who have provided informed consent. These biological samples are collected once before flight, during flight scheduled on flight days 15, 30, 60, 120 and within 2 weeks of landing. Postflight sessions are conducted 3 and 30 days after landing. The number of in-flight sessions is dependent on the duration of the mission. Specimens are maintained under optimal storage conditions in a manner that will maximize their integrity and viability for future research The repository operates under the authority of the NASA/JSC Committee for the Protection of Human Subjects to support scientific discovery that contributes to our fundamental knowledge in the area of human physiological changes and adaptation to a microgravity environment. The NBSR will institute guidelines for the solicitation, review and sample distribution process through establishment of the NBSR Advisory Board. The Advisory Board will be composed of representatives of all participating space agencies to evaluate each request from investigators for use of the samples. This process will be consistent with ethical principles, protection of crewmember confidentiality, prevailing laws and regulations, intellectual property policies, and consent form language. Operations supporting the NBSR are scheduled to continue until the end of U.S. presence on the ISS. Sample distribution is proposed to begin with selections on investigations beginning in 2017. The availability of the NBSR will contribute to the body of knowledge about the diverse factors of spaceflight on human physiology.

  20. Discrimination between intact and decayed pulp regions in carious teeth by ADC mapping.

    Science.gov (United States)

    Cankar, Ksenija; Nemeth, Lidija; Bajd, Franci; Vidmar, Jernej; Serša, Igor

    2014-01-01

    The aim of this study was to evaluate an advanced magnetic resonance imaging (MRI) method, apparent diffusion coefficient (ADC) mapping, in the functional assessment of carious teeth. 38 extracted human teeth with scores of 0, 3 and 6 according to International Caries Detection and Assessment System (ICDAS) criteria were screened and subsequently analyzed by MRI at 2.35 T. Histology sectioning of teeth was used for the gold standard by analyzing two extreme cases (intact and severely decayed). ADC maps of the same teeth were calculated from corresponding diffusion-weighted images and used to obtain ADC distributions along dental pulp as functions of the relative pulp length measured from the occlusal pulp side. The measured distributions were analyzed for the best fit by a four-parameter three-segment linear regression model for ADC distribution along the pulp. MRI results were in good agreement with findings in histological sections of identical teeth. The best fit model parameters, relative decayed region depth, relative transition region width and ADC values of intact and decayed pulp tissue, showed statistically significant differences between the ADC values of intact and decayed pulp tissue (1.0 × 10(-9) m(2)/s vs. 0.74-0.89 × 10(-9) m(2)/s) and the relative decayed region depth progressing with ICDAS score (3 vs. 46% with ICDAS 3 vs. ICDAS 6). The results of this feasibility study confirmed relevance of ADC mapping for the discrimination and localization of intact and decayed regions in dental pulps of carious teeth. © 2014 S. Karger AG, Basel.

  1. Utility of bronchial lavage fluids for epithelial growth factor receptor mutation assay in lung cancer patients: Comparison between cell pellets, cell blocks and matching tissue specimens

    Science.gov (United States)

    Asaka, Shiho; Yoshizawa, Akihiko; Nakata, Rie; Negishi, Tatsuya; Yamamoto, Hiroshi; Shiina, Takayuki; Shigeto, Shohei; Matsuda, Kazuyuki; Kobayashi, Yukihiro; Honda, Takayuki

    2018-01-01

    The detection of epidermal growth factor receptor (EGFR) mutations is necessary for the selection of suitable patients with non-small cell lung cancer (NSCLC) for treatment with EGFR tyrosine kinase inhibitors. Cytology specimens are known to be suitable for EGFR mutation detection, although tissue specimens should be prioritized; however, there are limited studies that examine the utility of bronchial lavage fluid (BLF) in mutation detection. The purpose of the present study was to investigate the utility of BLF specimens for the detection of EGFR mutations using a conventional quantitative EGFR polymerase chain reaction (PCR) assay. Initially, quantification cycle (Cq) values of cell pellets, cell-free supernatants and cell blocks obtained from three series of 1% EGFR mutation-positive lung cancer cell line samples were compared for mutation detection. In addition, PCR analysis of BLF specimens obtained from 77 consecutive NSCLC patients, detecting EGFR mutations was validated, and these results were compared with those for the corresponding formalin-fixed paraffin-embedded (FFPE) tissue specimens obtained by surgical resection or biopsy of 49 of these patients. The Cq values for mutation detection were significantly lower in the cell pellet group (average, 29.58) compared with the other groups, followed by those in cell-free supernatants (average, 34.15) and in cell blocks (average, 37.12) for all three series (P<0.05). Mutational status was successfully analyzed in 77 BLF specimens, and the results obtained were concordant with those of the 49 matching FFPE tissue specimens. Notably, EGFR mutations were even detected in 10 cytological specimens that contained insufficient tumor cells. EGFR mutation testing with BLF specimens is therefore a useful and reliable method, particularly when sufficient cancer cells are not obtained. PMID:29399190

  2. A tunable ratiometric pH sensor based on carbon nanodots for the quantitative measurement of the intracellular pH of whole cells.

    Science.gov (United States)

    Shi, Wen; Li, Xiaohua; Ma, Huimin

    2012-06-25

    The whole picture: Carbon nanodots labeled with two fluorescent dyes have been developed as a tunable ratiometric pH sensor to measure intracellular pH. The nanosensor shows good biocompatibility and cellular dispersibility. Quantitative determinations on intact HeLa cells and pH fluctuations associated with oxidative stress were performed. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Assessment of plastic flow and fracture properties with small specimens test techniques for IFMIF-designed specimens

    International Nuclear Information System (INIS)

    Spaetig, P.; Campitelli, E.N.; Bonade, R.; Baluc, N.

    2005-01-01

    The primary mission of the International Fusion Material Irradiation Facility (IFMIF) is to generate a material database to be used for the design of various components, for the licensing and for the assessment of the safe operation of a demonstration fusion reactor. IFMIF is an accelerator-based high-energy neutron source whose irradiation volume is quite limited (0.5 l for the high fluence volume). This requires the use of small specimens to measure the irradiation-induced changes on the physical and mechanical properties of materials. In this paper, we developed finite element models to better analyze the results obtained with two different small specimen test techniques applied to the tempered martensitic steel F82H-mod. First, one model was used to reconstruct the load-deflection curves of small ball punch tests, which are usually used to extract standard tensile parameters. It was shown that a reasonable assessment of the overall plastic flow can be done with small ball punch tests. Second, we investigated the stress field sensitivity at a crack tip to the constitutive behavior, for a crack modeled in plane strain, small-scale yielding and fracture mode I conditions. Based upon a local criterion for cleavage, that appears to be the basis to account for the size and geometry effects on fracture toughness, we showed that the details of the constitutive properties play a key role in modeling the irradiation-induced fracture toughness changes. Consequently, we suggest that much more attention and efforts have to be paid in investigating the post-yield behavior of the irradiated specimens and, in order to reach this goal, we recommend the use of not only tensile specimens but also that of compression ones in the IFMIF irradiation matrices. (author)

  4. Blood epididymal barrier to [3H]-inulin in intact and vasectomized hamsters

    International Nuclear Information System (INIS)

    Turner, T.T.; D'Addario, D.A.; Howards, S.S.

    1981-01-01

    The net transport of [ 3 H]-inulin into the fluids of the hamster seminiferous and caput, corpus, and cauda epididymal tubules was examined in both intact animals and those vasectomized 10 months previously. Mean isotope concentrations in reproductive tract tubule fluids did not exceeded 10 per cent of blood plasma isotope concentrations during the experiment. There were no significant differences in net transport of [ 3 H]-inulin into any of the tubule fluids sampled. Ten months after vasectomy, the seminiferous tubule, and all regions of the epididymal tubule retain the capacity to exclude [ 3 H]-insulin. Thus in the hamster 10 months after vasectomy, the blood testis and blood epididymal barriers to inulin are intact

  5. Effects of ignoring baseline on modeling transitions from intact cognition to dementia.

    Science.gov (United States)

    Yu, Lei; Tyas, Suzanne L; Snowdon, David A; Kryscio, Richard J

    2009-07-01

    This paper evaluates the effect of ignoring baseline when modeling transitions from intact cognition to dementia with mild cognitive impairment (MCI) and global impairment (GI) as intervening cognitive states. Transitions among states are modeled by a discrete-time Markov chain having three transient (intact cognition, MCI, and GI) and two competing absorbing states (death and dementia). Transition probabilities depend on two covariates, age and the presence/absence of an apolipoprotein E-epsilon4 allele, through a multinomial logistic model with shared random effects. Results are illustrated with an application to the Nun Study, a cohort of 678 participants 75+ years of age at baseline and followed longitudinally with up to ten cognitive assessments per nun.

  6. Intact and Degraded Component Criticality Calculations of N Reactor Spent Nuclear Fuel

    International Nuclear Information System (INIS)

    L. Angers

    2001-01-01

    The objective of this calculation is to perform intact and degraded mode criticality evaluations of the Department of Energy's (DOE) N Reactor Spent Nuclear Fuel codisposed in a 2-Defense High-Level Waste (2-DHLW)/2-Multi-Canister Overpack (MCO) Waste Package (WP) and emplaced in a monitored geologic repository (MGR) (see Attachment I). The scope of this calculation is limited to the determination of the effective neutron multiplication factor (k eff ) for both intact and degraded mode internal configurations of the codisposal waste package. This calculation will support the analysis that will be performed to demonstrate the technical viability for disposing of U-metal (N Reactor) spent nuclear fuel in the potential MGR

  7. Comparison of umbilical cord interleukin-6 in preterm infants with premature rupture of membranes and intact membranes

    International Nuclear Information System (INIS)

    Gharebaghi, Manizheh M.; Peirovifar, A.; Gharebaghi, Parvin M.

    2008-01-01

    Objective was to compare inflammatory mediators in the cord blood of premature newborn infants with premature rupture of membranes (PROM) and intact membranes. Eighty-nine premature neonates with gestational age of 27-34 weeks that delivered in Ghaem Hospital in Mashhad, Iran from June 2005 to March 2006 were enrolled in a prospective observational study and their umbilical cord plasma was collected at birth. They were allocated into 2 groups (45 patients with PROM and 44 neonates with intact membranes). Interleukin-6 (IL-6) and C-reactive protein (CRP) levels were measured in cord plasma by the enzyme linked immunoassay (ELISA) method. Mean cord plasma IL-6 levels in preterm neonates with PROM was 205.71 pg/ml and in neonates with intact membranes was 33.3 pg/ml for IL-6 (p=0.000). The mean cord blood CRP level in newborns was 10.2 ug/ml, and in those with intact membranes was 1.6 ug/ml and in those with intact membranes was 1.6 ug/ml (p=0.41). Early onset sepsis was more frequent in infants with PROM than premature infants with intact membrane (38% versus 10%, p=0.001). In neonates with PROM, the mean cord blood IL-6 level was significantly higher in septic newborns (414.28 versus 40.44 pg/ml, p=0.000). The premature newborn infants with PROM had increased IL-6 levels in cord blood, which was significantly higher in neonates that developed early onset sepsis. (author)

  8. Specimen's plane misaligned installation solution based on charge fluctuation inside SEM

    Science.gov (United States)

    Lu, Haojian; Liu, Yanting; Yang, Yuanyuan; Wang, Panbing; Shen, Yajing

    2018-04-01

    Precise specimen's installation is a sticking point to ensure the characterization accuracy of the in-situ material property test. Although it is common knowledge that specimen's plane misaligned installation (PMI) would cause extra force loading during mechanical testing, there are few effective solutions available to deal with it at the current stage, especially during the in-situ scanning electron microscopy (SEM) test. Taking into consideration the charge fluctuation phenomenon under SEM, this paper proposes a highlight area variation (HAV) method for specimen deformation judgment, i.e., the specimen deformation is defined when the highlight area changes greater than 20% of the initial value of the specimen surface. Three types of specimens with different resistivities, i.e., human hair (electrical resistivity ˜3 × 1012 Ω cm), optical fiber (electrical resistivity ˜1017 Ω cm), and magnetic wire (electrical resistivity ˜2 × 10-5 Ω cm), are chosen to verify the effectiveness of the HAV method. Furthermore, combined with the developed robot-aided alignment system, the specimen's PMI problem can also be solved. In the demonstration, the human hair specimen is installed across two specimen stages and its in-situ twisting (in 360°) test is implemented. The results clearly indicate that the HAV method and the robot-aided alignment system are practical and reliable, and the specimen can be aligned on the same plane and installed precisely with accuracy up to 3 μm. This method will benefit the in-situ SEM material mechanical property test and has a significant impact in fundamental material research.

  9. Radiation-induced adaptive response in the intact mouse

    International Nuclear Information System (INIS)

    Yonezawa, Morio

    2009-01-01

    The author and coworkers have revealed that radiation adaptive response (AR) is seen also in the bone marrow of the intact mouse, of which details are described here. First, SPF ICR mice were pre-irradiated (PI) with 0-0.1 Gy of X-ray and after 2 months, subsequently irradiated (SI) with 7.75 Gy. Survival rates at 30 days after SI were about 14% in mice with PI 0-0.025 Gy whereas 40% or more in animals with PI 0.05-0.1 Gy: bone marrow death was found significantly suppressed in this effective PI dose range. The death 2 weeks after SI was found also inhibited at PI 0.3-0.5 Gy. Second, PI doses and interval between PI and SI for acquiring the radio-resistance (RR) were studied and third, the PI 0.3-0.5 Gy with SI 8.0 Gy at 9-17 days later revealed that regional PI of the head (central nervous system) was found unnecessary for RR and of abdomen (systems of hemopoiesis, immunity and digestion), essential. Fourth, strain difference of RR was shown by the fact that RR was observed only in C57BL mouse as well, but neither in BALB/c nor C3H strain. Next, at 12 days after SI 4.25-6.75 Gy (PI 0.5 Gy at 14 days before), mouse spleen cells were subjected to colony formation analysis by counting the endogenous hemopoietic stem cells, which revealed that those cells were increased to about 5 times by PI. Suppression of SI-induced hemorrhage was found in mice with PI by the decreased fecal hemoglobin content. Finally, AR was similarly studied in p53 +/+ and its knockout C57BL mice and was not found in the latter animal, indicating the participation of p53 in AR of the intact mouse. Elucidation of AR mechanisms in the intact animal seems to require somewhat different aspect from that in cells. The results were controvertible to the general concept that radiation risk is proportional to cumulative dose, suggesting that low dose radiation differs from high dose one in biological effect. (K.T.)

  10. Visualization test using piping group mock up specimen for evaluation of wastage phenomena in steam generator for FBR

    International Nuclear Information System (INIS)

    Kato, Keisuke; Yoshida, Atsuro; Arae, Kunihiko; Narabayashi, Tadashi; Ohshima, Hiroyuki; Kurihara, Akikazu

    2012-01-01

    There is a need for quantitative evaluation of wastage phenomena in steam generator for FBR. We focused attention on liquid droplet impingement erosion (LDIE) in wastage phenomena and performed basic study with piping group mock up specimen for quantitative evaluation of LDIE. First, we did visualization test of high pressure and high speed jet into the water. Test section mock up the crack of heat exchanger tube and neighboring heat exchanger tubes. We did the test under the following test conditions. Upstream pressure is 0.3MPa, vapor temperature is 300K, crack width is 0.1mm, and crack length is 40mm. (crack diameter is 0.2mm) Second, we did pressure and temperature measurement test in the same test conditions as before. We evaluated jet behavior at test section by those two tests. In addition, we did two phase flow analysis of the jet with TRAC code. (author)

  11. Fracture mechanics characterisation of medium-size adhesive joint specimens

    DEFF Research Database (Denmark)

    Sørensen, Bent F.; Jacobsen, T.K.

    2004-01-01

    Medium-size specimens (glass-fibre beams bonded together by an adhesive layer were tested in four point bending to determine their load carrying capacity. Specimens having different thickness were tested. Except for onespecimen, the cracking occurred as cracking...... along the adhesive layer; initially cracking occurred along the adhesive/laminate interface, but after some crack extension the cracking took place inside the laminate (for one specimen the later part of thecracking occurred unstably along the adhesive/ laminate interface). Crack bridging by fibres...

  12. A proposed standard round compact specimen for plane strain fracture toughness testing

    Science.gov (United States)

    Underwood, J. H.; Newman, J. C., Jr.; Seeley, R. R.

    1980-01-01

    A round, disk-shaped specimen is proposed as a standard test specimen for addition to ASTM Test for Plane-Strain Fracture Toughness of Metallic Materials (E 399-78A). The specimen is diametrically cracked, and loaded in the same way as the existing standard compact specimen. Tests and analyses were performed to verify that the proposed round compact specimen and associated stress intensity factor K solution are appropriate for a standard plane strain fracture toughness test. The use of the round compact specimen for other fracture tests is described.

  13. Test methodology and technology of fracture toughness for small size specimens

    Energy Technology Data Exchange (ETDEWEB)

    Wakai, E.; Takada, F.; Ishii, T.; Ando, M. [Japan Atomic Energy Agency, Naga-gun, Ibaraki-ken (Japan); Matsukawa, S. [JNE Techno-Research Co., Kanagawa-ken (Japan)

    2007-07-01

    Full text of publication follows: Small specimen test technology (SSTT) is required to investigate mechanical properties in the limited availability of effective irradiation volumes in test reactors and accelerator-based neutron and charged particle sources. The test methodology guideline and the manufacture processes for very small size specimens have not been established, and we would have to formulate it. The technology to control exactly the load and displacement is also required in the test technology under the environment of high dose radiation produced from the specimens. The objective of this study is to examine the test technology and methodology of fracture toughness for very small size specimens. A new bend test machine installed in hot cell has been manufactured to obtain fracture toughness and DBTT (ductile - brittle transition temperature) of reduced-activation ferritic/martensitic steels for small bend specimens of t/2-1/3PCCVN (pre-cracked 1/3 size Charpy V-notch) with 20 mm length and DFMB (deformation and fracture mini bend specimen) with 9 mm length. The new machine can be performed at temperatures from -196 deg. C to 400 deg. C under unloading compliance method. Neutron irradiation was also performed at about 250 deg. C to about 2 dpa in JMTR. After the irradiation, fracture toughness and DBTT were examined by using the machine. Checking of displacement measurement between linear gauge of cross head's displacement and DVRT of the specimen displacement was performed exactly. Conditions of pre-crack due to fatigue in the specimen preparation were also examined and it depended on the shape and size of the specimens. Fracture toughness and DBTT of F82H steel for t/2-1/3PCCVN, DFMB and 0.18DCT specimens before irradiation were examined as a function of temperature. DBTT of smaller size specimens of DFMB was lower than that of larger size specimen of t/2-1/3PCCVN and 0.18DCT. The changes of fracture toughness and DBTT due to irradiation were also

  14. Quantitative phase microscopy for cellular dynamics based on transport of intensity equation.

    Science.gov (United States)

    Li, Ying; Di, Jianglei; Ma, Chaojie; Zhang, Jiwei; Zhong, Jinzhan; Wang, Kaiqiang; Xi, Teli; Zhao, Jianlin

    2018-01-08

    We demonstrate a simple method for quantitative phase imaging of tiny transparent objects such as living cells based on the transport of intensity equation. The experiments are performed using an inverted bright field microscope upgraded with a flipping imaging module, which enables to simultaneously create two laterally separated images with unequal defocus distances. This add-on module does not include any lenses or gratings and is cost-effective and easy-to-alignment. The validity of this method is confirmed by the measurement of microlens array and human osteoblastic cells in culture, indicating its potential in the applications of dynamically measuring living cells and other transparent specimens in a quantitative, non-invasive and label-free manner.

  15. Transfer Comparison Study Nitrogen on the Intact and Decapitated Legumes by Using the 15N Labeling Technique

    International Nuclear Information System (INIS)

    Widjayanto, Didik W.

    1998-01-01

    The experiment was done in order to evaluate the N transfer from the intact and decapitated legumes by using the 15 N labeling technique. Seven days after final labeling the above ground biomass from labeled legume species was removed and the remaining stalks capped to prevent regrowth. Twenty days after final labeling (fourteen days after capping) the all treatments were sample and analyzed. The decapitated legumes appeared to transfer more percentage N than the intact legumes. Although both decapitated and intact legumes transferred, the transfer of N did not incur a dry matter and N yield benefit

  16. Old Plants, New Tricks: Phenological Research Using Herbarium Specimens.

    Science.gov (United States)

    Willis, Charles G; Ellwood, Elizabeth R; Primack, Richard B; Davis, Charles C; Pearson, Katelin D; Gallinat, Amanda S; Yost, Jenn M; Nelson, Gil; Mazer, Susan J; Rossington, Natalie L; Sparks, Tim H; Soltis, Pamela S

    2017-07-01

    The timing of phenological events, such as leaf-out and flowering, strongly influence plant success and their study is vital to understanding how plants will respond to climate change. Phenological research, however, is often limited by the temporal, geographic, or phylogenetic scope of available data. Hundreds of millions of plant specimens in herbaria worldwide offer a potential solution to this problem, especially as digitization efforts drastically improve access to collections. Herbarium specimens represent snapshots of phenological events and have been reliably used to characterize phenological responses to climate. We review the current state of herbarium-based phenological research, identify potential biases and limitations in the collection, digitization, and interpretation of specimen data, and discuss future opportunities for phenological investigations using herbarium specimens. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Design of four-point SENB specimens with stable crack growth

    DEFF Research Database (Denmark)

    Jørgensen, Jeppe Bjørn; Kildegaard, Casper; Sørensen, Bent F.

    2018-01-01

    A four-point single-edge-notch-beam (SENB) test specimen loaded in displacement control (fixed grip) is proposed for studying crack deflection at bi-material interfaces. In order to ensure stable crack growth, a novel analytical model of the four-point SENB specimen in fixed grip is derived...... and compared with numerical models. Model results show that the specimen should be short and thick, and the start-crack length should be deep for the crack to propagate stable towards the bi-material interface. Observations from experimental tests of four-point SENB specimens with different start-crack lengths...

  18. Quantitative EDXS analysis of organic materials using the ζ-factor method

    International Nuclear Information System (INIS)

    Fladischer, Stefanie; Grogger, Werner

    2014-01-01

    In this study we successfully applied the ζ-factor method to perform quantitative X-ray analysis of organic thin films consisting of light elements. With its ability to intrinsically correct for X-ray absorption, this method significantly improved the quality of the quantification as well as the accuracy of the results compared to conventional techniques in particular regarding the quantification of light elements. We describe in detail the process of determining sensitivity factors (ζ-factors) using a single standard specimen and the involved parameter optimization for the estimation of ζ-factors for elements not contained in the standard. The ζ-factor method was then applied to perform quantitative analysis of organic semiconducting materials frequently used in organic electronics. Finally, the results were verified and discussed concerning validity and accuracy. - Highlights: • The ζ-factor method is used for quantitative EDXS analysis of light elements. • We describe the process of determining ζ-factors from a single standard in detail. • Organic semiconducting materials are successfully quantified

  19. Molecular detection of candida species from hospitalized patient’s specimens.

    Science.gov (United States)

    Camacho-Cardoso, José Luis; Martínez-Rivera, María Ángeles; Manzano-Gayosso, Patricia; Méndez-Tovar, Luis Javier; López-Martínez, Rubén; Hernández-Hernández, Francisca

    To identify the most frequent Candida species in specimens from patients hospitalized in different medical centers of Mexico City, with suspected fungal infection. Specimens were grown on Sabouraud dextrose agar at 28°C for 72 h. In addition, DNA was extracted. Isolates were grown on CHROMagar Candida™, at 37°C for 48 h. The molecular identification was performed by polymerase chain reaction (PCR) using primers specific for four species. Eighty one specimens were processed and included: bronchial lavage, pleural, cerebrospinal, peritoneal, ascites and bile fluids; blood, sputum, bone marrow, oro-tracheal cannula and ganglion. By culture, 30 samples (37%) were positive, and by PCR, 41 (50.6%). By PCR, the frequency of species was: Candida albicans 82.9%, Candida tropicalis 31.7%, Candida glabrata 24.4%, and Candida parapsilosis 4.9%. In 34.1% of specimens a species mixture was detected suggesting a co-infection: Two species in five specimens (C. albicans-C tropicalis and C. albicans-C glabrata), and three species in three specimens (C. albicans-C. glabrata-C. tropicalis). The PCR is an useful tool for detection the most common Candida species causing infection in hospitalized patients, it avoids the requirement of culture weather we start from clinical specimen and it favors the early diagnosis of invasive candidiasis. Copyright: © 2017 SecretarÍa de Salud

  20. Stress-deformed state of cylindrical specimens during indirect tensile strength testing

    Directory of Open Access Journals (Sweden)

    Levan Japaridze

    2015-10-01

    Full Text Available In this study, the interaction between cylindrical specimen made of homogeneous, isotropic, and linearly elastic material and loading jaws of any curvature is considered in the Brazilian test. It is assumed that the specimen is diametrically compressed by elliptic normal contact stresses. The frictional contact stresses between the specimen and platens are neglected. The analytical solution starts from the contact problem of the loading jaws of any curvature and cylindrical specimen. The contact width, corresponding loading angle (2θ0, and elliptical stresses obtained through solution of the contact problems are used as boundary conditions for a cylindrical specimen. The problem of the theory of elasticity for a cylinder is solved using Muskhelishvili's method. In this method, the displacements and stresses are represented in terms of two analytical functions of a complex variable. In the main approaches, the nonlinear interaction between the loading bearing blocks and the specimen as well as the curvature of their surfaces and the elastic parameters of their materials are taken into account. Numerical examples are solved using MATLAB to demonstrate the influence of deformability, curvature of the specimen and platens on the distribution of the normal contact stresses as well as on the tensile and compressive stresses acting across the loaded diameter. Derived equations also allow calculating the modulus of elasticity, total deformation modulus and creep parameters of the specimen material based on the experimental data of radial contraction of the specimen.

  1. Creep life assessment of Mod.9Cr-1Mo steel. Pt. 1. Quantitative evaluation of microstructural damage in creep rupture specimens

    International Nuclear Information System (INIS)

    Sawada, Kota; Maruyama, Kouichi; Komine, Ryuji; Nagae, Yuji

    1997-03-01

    Several microstructural changes take place in a material during the course of creep. These changes can be a measure of creep life consumption. In this paper, microstructural changes in Mod.9Cr-1Mo steel were studied in order to examine their ability as the measure of creep life consumption. Macroscopic structural changes, such as void growth, rotation of lath structure toward the tensile axis and elongation of grains, are evident only in the necked portion of ruptured specimens. These macroscopic structural changes are not useful for creep life assessment. Lath width increases and dislocation density within lath decreases with increasing creep duration. These changes in dislocation substructure start in the early stage of creep life, and cause the increase of strain rate in the tertiary creep stage. The lath width and the dislocation density reach a stationary value before rupture. The stationary values are independent of temperature, and uniquely related to creep stress normalized by shear modulus. The extent of these microstructural changes are greater at lower stresses under which the material is practically used. These facts suggest that the lath width and the dislocation density within lath can be a useful measure of creep life consumption. Hardness of crept specimens is closely related to the lath width and the dislocation density within lath. The changes of these microstructural features can be evaluated by the measurement of hardness. (author)

  2. Specimen environments in thermal neutron scattering experiments

    International Nuclear Information System (INIS)

    Cebula, D.J.

    1980-11-01

    This report is an attempt to collect into one place outline information concerning the techniques used and basic design of sample environment apparatus employed in neutron scattering experiments. Preliminary recommendations for the specimen environment programme of the SNS are presented. The general conclusion reached is that effort should be devoted towards improving reliability and efficiency of operation of specimen environment apparatus and developing systems which are robust and easy to use, rather than achieving performance at the limits of technology. (author)

  3. In vitro evaluation of percutaneous diffusion of uranyl nitrate through intact or excoriated skin of rat and pig

    International Nuclear Information System (INIS)

    Petitot, F.; Moreels, A.M.; Paquet, F.

    2004-01-01

    At the present time, the International Commission on Radiological Protection (ICRP) has not published any model concerning internal radioactive contamination by uptake from wounds. The aims of our work were to determine the time available to treat contamination of intact or wounded skin before a significant uptake of uranium occurred and to evaluate the consequences of incomplete decontamination on uranium uptake. The kinetics of percutaneous diffusion of uranium through intact or excoriated skin and its distribution in skin layers were evaluated using an in vitro technique. Our data demonstrated a dramatic increase of uranium percutaneous diffusion through excoriated skin compared with intact skin. Significant uptake of uranium through excoriated skin occurred in only 30 min, indicating that there is only a short interval available to treat a contaminated wound effectively. Moreover, in the case of an incompletely decontaminated superficial wound, viable epidermis behaved as a reservoir for uranium that remained bioavailable. At the present time, potential uptake of uranium and perhaps other radionuclides through intact or wounded skin is not adequately taken into account by radiological protection agencies. Our results emphasize the need for further study and modeling of uptake of radionuclides through intact or wounded skin. (author)

  4. Influence of fluoride varnish on shear bond strength of a universal adhesive on intact and demineralized enamel.

    Science.gov (United States)

    Ortiz-Ruiz, Antonio José; Muñoz-Gómez, Iban Jesús; Pérez-Pardo, Ana; Germán-Cecilia, Concepción; Martínez-Beneyto, Yolanda; Vicente, Ascensión

    2018-04-27

    The aim was to evaluate the effect of fluoride varnish on the shear bond strength (SBS) on polished and non-polished intact and demineralized enamel. Bovine incisors (half demineralized) were used. Bifluorid 12™ was applied. Bonding was made with Futurabond ® M + and GrandioSO, 24 h and 7 days after varnishing. In some groups, varnish was removed by polishing before bonding. SBS was measured. Fracture type was determined by stereomicroscopy and scanning electron microscope (SEM) observations of the enamel surface were made. Between-group differences were determined by one-way ANOVA and the Tukey test. Associations between study factors and fracture modes were analysed using contingency tables and Pearson's chi-squared test. For intact enamel, SBS on varnished enamel at 24 h was significantly less than in the other groups. SBS recovered 7 days after varnishing. Varnish elimination after 24 h significantly increased the SBS. However, removal at 7 days did not modify SBS. SBS on demineralized enamel groups was significantly less than in intact enamel, except for demineralized enamel varnished and removed at 7 days. Demineralized enamel was associated with cohesive enamel fractures and intact enamel with cohesive fractures of the composite and adhesive fractures. SEM of varnish surfaces showed a homogenous layer scattered with amorphous precipitate. In conclusion, on intact enamel fluoride varnish had a negative effect on SBS at 24 h, which disappeared after 7 days. On demineralized enamel, varnish did not reduce SBS at either time. Polishing the varnished enamel surface showed a similar SBS to intact enamel after 7 days.

  5. Post-deformation examination of specimens subjected to SCC testing

    Energy Technology Data Exchange (ETDEWEB)

    Gussev, Maxim N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Field, Kevin G. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Busby, Jeremy T. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Leonard, Keith J. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-09-01

    This report details the results of post-radiation and post-deformation characterizations performed during FY 2015–FY 2016 on a subset of specimens that had previously been irradiated at high displacement per atom (dpa) damage doses. The specimens, made of commercial austenitic stainless steels and alloys, were subjected to stress-corrosion cracking tests (constant extension rate testing and crack growth testing) at the University of Michigan under conditions typical of nuclear power plants. After testing, the specimens were returned to Oak Ridge National Laboratory (ORNL) for further analysis and evaluation.

  6. An electronic specimen collection protocol schema (eSCPS). Document architecture for specimen management and the exchange of specimen collection protocols between biobanking information systems.

    Science.gov (United States)

    Eminaga, O; Semjonow, A; Oezguer, E; Herden, J; Akbarov, I; Tok, A; Engelmann, U; Wille, S

    2014-01-01

    The integrity of collection protocols in biobanking is essential for a high-quality sample preparation process. However, there is not currently a well-defined universal method for integrating collection protocols in the biobanking information system (BIMS). Therefore, an electronic schema of the collection protocol that is based on Extensible Markup Language (XML) is required to maintain the integrity and enable the exchange of collection protocols. The development and implementation of an electronic specimen collection protocol schema (eSCPS) was performed at two institutions (Muenster and Cologne) in three stages. First, we analyzed the infrastructure that was already established at both the biorepository and the hospital information systems of these institutions and determined the requirements for the sufficient preparation of specimens and documentation. Second, we designed an eSCPS according to these requirements. Finally, a prospective study was conducted to implement and evaluate the novel schema in the current BIMS. We designed an eSCPS that provides all of the relevant information about collection protocols. Ten electronic collection protocols were generated using the supplementary Protocol Editor tool, and these protocols were successfully implemented in the existing BIMS. Moreover, an electronic list of collection protocols for the current studies being performed at each institution was included, new collection protocols were added, and the existing protocols were redesigned to be modifiable. The documentation time was significantly reduced after implementing the eSCPS (5 ± 2 min vs. 7 ± 3 min; p = 0.0002). The eSCPS improves the integrity and facilitates the exchange of specimen collection protocols in the existing open-source BIMS.

  7. Using Spores for Fusarium spp. Classification by MALDI-Based Intact Cell/Spore Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Wolfgang Winkler

    2012-01-01

    Full Text Available Fusarium is a widespread genus of filamentous fungi and a member of the soil microbial community. Certain subspecies are health threatening because of their mycotoxin production that affects the human and animal food chain. Thus, for early and effective pest control, species identification is of particular interest; however, differentiation on the subspecies level is challenging and time-consuming for this fungus. In the present study, we show the possibilities of intact cell mass spectrometry for spore analysis of 22 different Fusarium strains belonging to six Fusarium subspecies. We found that species differentiation is possible if mass spectrometric analyses are performed under well-defined conditions with fixed parameters. A critical point for analysis is a proper sample preparation of spores, which increases the quality of mass spectra with respect to signal intensity and m/z value variations. It was concluded that data acquistion has to be performed automatically; otherwise, user-specific variations are introduced generating data which cannot fit the existing datasets. Data that show clearly that matrix-assisted laser desorption ionization-based intact cell/intact spore mass spectrometry (IC/ISMS can be applied to differentiate closely related Fusarium spp. are presented. Results show a potential to build a database on Fusarium species for accurate species identification, for fast response in the case of infections in the cornfield. We furthermore demonstrate the high precision of our approach in classification of intact Fusarium species according to the location of their collection.

  8. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  9. Catalog of insect type specimens preserved at the Kunming Institute of Zoology, Chinese Academy of Science with corrections of some specimens.

    Science.gov (United States)

    Li, Kai-Qin; Wang, Yun-Zhen; Dong, Da-Zhi; Zhang, Li-Kun

    2015-09-18

    This article presents a list of insect types preserved in Kunming Natural History Museum of Zoology (KNHMZ). As of March, 2015, 3 412 type specimens belonging to 266 species/subspecies of 37 families in 9 orders (Odonata, Isoptera, Mantodea, Orthoptera, Hemiptera, Coleoptera, Diptera, Hymenoptera and Lepidoptera) are included. Information corrections of some specimens are provided in this article.

  10. Location specific in situ TEM straining specimens made using FIB

    International Nuclear Information System (INIS)

    Field, R.D.; Papin, P.A.

    2004-01-01

    A method has been devised and demonstrated for producing in situ straining specimens for the transmission electron microscope (TEM) from specific locations in a sample using a dual-beam focused ion beam (FIB) instrument. The specimen is removed from a polished surface in the FIB using normal methods and then attached to a pre-fabricated substrate in the form of a modified TEM tensile specimen. In this manner, specific features of the microstructure of a polished optical mount can be selected for in situ tensile straining. With the use of electron backscattered diffraction (EBSD), this technique could be extended to select specific orientations of the specimen as well

  11. Uniaxial compression tests on diesel contaminated frozen silty soil specimens

    International Nuclear Information System (INIS)

    Chenaf, D.; Stampli, N.; Bathurst, R.; Chapuis, R.P.

    1999-01-01

    Results of a uniaxial, unconfined compression test on artificial diesel-contaminated and uncontaminated frozen silty soils are discussed. The testing program involved 59 specimens. The results show that for the same fluid content, diesel contamination reduced the strength of the frozen specimens by increasing the unfrozen water content. For example, in specimens containing 50 per cent diesel oil of the fluid content by weight the maximum strength was reduced by 95 per cent compared to the strength of an uncontaminated specimen. Diesel contamination was also shown to contribute to the slippage between soil particles by acting as a lubricant, thus accelerating the loss of compressive strength.13 refs., 18 figs

  12. Images of paraffin monolayer crystals with perfect contrast: minimization of beam-induced specimen motion

    Science.gov (United States)

    Glaeser, R.M.; McMullan, G.; Faruqi, A.R.; Henderson, R.

    2013-01-01

    Quantitative analysis of electron microscope images of organic and biological two-dimensional crystals has previously shown that the absolute contrast reached only a fraction of that expected theoretically from the electron diffraction amplitudes. The accepted explanation for this is that irradiation of the specimen causes beam-induced charging or movement, which in turn causes blurring of the image due to image or specimen movement. In this paper, we used three different approaches to try to overcome this image-blurring problem for monolayer crystals of paraffin. Our first approach was to use an extreme form of spotscan imaging, in which a single image was assembled on film by the successive illumination of up to 50,000 spots each of diameter around 7nm. The second approach was to use the Medipix II detector with its zero-noise readout to assemble a time-sliced series of images of the same area in which each frame from a movie with up to 400 frames had an exposure of only 500 electrons. In the third approach, we simply used a much thicker carbon support film to increase the physical strength and conductivity of the support. Surprisingly, the first two methods involving dose fractionation respectively in space or time produced only partial improvements in contrast whereas the third approach produced many virtually perfect images, in which the absolute contrast predicted from the electron diffraction amplitudes was observed in the images. We conclude that it is possible to obtain consistently almost perfect images of beam-sensitive specimens if they are attached to an appropriately strong and conductive support, but great care is needed in practice and the problem of how best to image ice-embedded biological structures in the absence of a strong, conductive support film requires more work. PMID:21185452

  13. The effect of self-transcendence on depression in cognitively intact nursing home patients.

    Science.gov (United States)

    Haugan, Gørill; Innstrand, Siw Tone

    2012-01-01

    Aims. This study's aim was to test the effects of self-transcendence on depression among cognitively intact nursing home patients. Background. Depression is considered the most frequent mental disorder among the elderly population. Specifically, the depression rate among nursing home patients is three to four times higher than that among community-dwelling elderly. Therefore, finding new and alternative ways to prevent and decrease depression is of great importance for nursing home patients' well-being. Self-transcendence is related to spiritual as well as nonspiritual factors, and it is described as a correlate and resource for well-being among vulnerable populations and at the end of life. Methods. A two-factor construct of the self-transcendence scale (interpersonal and intrapersonal) and the hospital anxiety and depression scale (HADS) was applied. A sample of 202 cognitively intact nursing home patients in central Norway was selected to respond to the questionnaires in 2008/2009. Results. A hypothesized SEM model demonstrated significant direct relationships and total effects of self-transcendence on depression. Conclusion and Implication for Practice. Facilitating patients' self-transcendence, both interpersonally and intrapersonally, might decrease depression among cognitively intact nursing home patients.

  14. The effect of kidney morcellation on operative time, incision complications, and postoperative analgesia after laparoscopic nephrectomy

    Directory of Open Access Journals (Sweden)

    Affonso H. Camargo

    2006-06-01

    Full Text Available INTRODUCTION: Compare the outcomes between kidney morcellation and two types of open specimen extraction incisions, several covariates need to be taken into consideration that have not yet been studied. MATERIALS AND METHODS: We retrospectively reviewed 153 consecutive patients who underwent laparoscopic nephrectomy at our institution, 107 who underwent specimen morcellation and 46 with intact specimen removal, either those with connected port sites with a muscle-cutting incision and those with a remote, muscle-splitting incision. Operative time, postoperative analgesia requirements, and incisional complications were evaluated using univariate and multivariate analysis, comparing variables such as patient age, gender, body mass index (BMI, laterality, benign versus cancerous renal conditions, estimated blood loss, specimen weight, overall complications, and length of stay. RESULTS: There was no significant difference for operative time between the 2 treatment groups (p = 0.65. Incision related complications occurred in 2 patients (4.4% from the intact specimen group but none in the morcellation group (p = 0.03. Overall narcotic requirement was lower in patients with morcellated (41 mg compared to intact specimen retrieval (66 mg on univariate (p = 0.03 and multivariate analysis (p = 0.049. Upon further stratification, however, there was no significant difference in mean narcotic requirement between the morcellation and muscle-splitting incision subgroup (p = 0.14. CONCLUSION: Morcellation does not extend operative time, and is associated with significantly less postoperative pain compared to intact specimen retrieval overall, although this is not statistically significant if a remote, muscle-splitting incision is made. Morcellation markedly reduces the risk of incisional-related complications.

  15. Effects of Specimen Diameters on the Distribution of Corrosion Fatigue Cracks

    OpenAIRE

    石原, 外美; 塩澤, 和章; 宮尾, 嘉寿

    1988-01-01

    The distribution of corrosion fatigue cracks observed on the un-notched round specimen surface differs with specimen diameter, especially in the low stress amplitude region. At a constant fatigue life ratio, many long cracks are initiated on the larger specimen, 12 mm (diameter), in comparison with the smaller specimen, 6 mm (diameter). On the other hand, in the high stress amplitude region of corrosion fatigue and fatigue in laboratory air, the distribution of cracks during the fatigue proce...

  16. Detecting Rickettsia parkeri Infection from Eschar Swab Specimens

    Science.gov (United States)

    2013-05-01

    Detecting Rickettsia parkeri Infection from Eschar Swab Specimens Todd Myers, Tahaniyat Lalani, Mike Dent, Ju Jiang, Patrick L. Daly, Jason D...Maguire, and Allen L. Richards The typical clinical presentation of several spotted fever group Rickettsia infections includes eschars. Clinical...diagnosis by using an eschar swab specimen from patients infected with Rickettsia parkeri. Until 2004, all confirmed cases of tick-borne spotted

  17. Construction of disturbed and intact soil blocks to develop percolating soil based treatment systems for dirty water from dairy farms.

    Science.gov (United States)

    Brookman, S K E; Chadwick, D R; Headon, D M

    2002-03-01

    Intact soil blocks with a surface area of 1.8 x 1.6 m, 1.0 m deep, were excavated in a coarse sandy loam. The sides of the soil blocks were supported with plywood before using hydraulic rams to force a steel cutting plate beneath them. Disturbed soil blocks of the same depth as the intact blocks were also established. Experiments were conducted to determine purification efficiencies for biological oxygen demand (BOD), molybdate reactive phosphorus (MRP), nitrate and ammonium-N after the application of dirty water. A preliminary experiment is described where a low application of dirty water was applied to the soil blocks, 2 mm day(-1). In addition, a chloride tracer was conducted for the duration of the experiment. Disturbed soil had a purification efficiency for BOD of 99% compared to 96% from intact soil (Pammonium-N were 100 and 99%, respectively, for the intact and disturbed soils. Nitrate-N concentration increased in leachate from both treatments reaching maximum concentrations of 15 and 8 mg l(-1) from disturbed and intact soils, respectively. Chloride traces for each soil block followed similar patterns with 47 and 51% loss from disturbed and intact soils, respectively.

  18. Screening hypochromism (sieve effect) in red blood cells: a quantitative analysis.

    Science.gov (United States)

    Razi Naqvi, K

    2014-04-01

    Multiwavelength UV-visible spectroscopy, Kramers-Kronig analysis, and several other experimental and theoretical tools have been applied over the last several decades to fathom absorption and scattering of light by suspensions of micron-sized pigmented particles, including red blood cells, but a satisfactory quantitative analysis of the difference between the absorption spectra of suspension of intact and lysed red blood cells is still lacking. It is stressed that such a comparison is meaningful only if the pertinent spectra are free from, or have been corrected for, scattering losses, and it is shown that Duysens' theory can, whereas that of Vekshin cannot, account satisfactorily for the observed hypochromism of suspensions of red blood cells.

  19. Quantitative x-ray dark-field computed tomography

    International Nuclear Information System (INIS)

    Bech, M; Pfeiffer, F; Bunk, O; Donath, T; David, C; Feidenhans'l, R

    2010-01-01

    The basic principles of x-ray image formation in radiology have remained essentially unchanged since Roentgen first discovered x-rays over a hundred years ago. The conventional approach relies on x-ray attenuation as the sole source of contrast and draws exclusively on ray or geometrical optics to describe and interpret image formation. Phase-contrast or coherent scatter imaging techniques, which can be understood using wave optics rather than ray optics, offer ways to augment or complement the conventional approach by incorporating the wave-optical interaction of x-rays with the specimen. With a recently developed approach based on x-ray optical gratings, advanced phase-contrast and dark-field scatter imaging modalities are now in reach for routine medical imaging and non-destructive testing applications. To quantitatively assess the new potential of particularly the grating-based dark-field imaging modality, we here introduce a mathematical formalism together with a material-dependent parameter, the so-called linear diffusion coefficient and show that this description can yield quantitative dark-field computed tomography (QDFCT) images of experimental test phantoms.

  20. Mesh-morphing algorithms for specimen-specific finite element modeling.

    Science.gov (United States)

    Sigal, Ian A; Hardisty, Michael R; Whyne, Cari M

    2008-01-01

    Despite recent advances in software for meshing specimen-specific geometries, considerable effort is still often required to produce and analyze specimen-specific models suitable for biomechanical analysis through finite element modeling. We hypothesize that it is possible to obtain accurate models by adapting a pre-existing geometry to represent a target specimen using morphing techniques. Here we present two algorithms for morphing, automated wrapping (AW) and manual landmarks (ML), and demonstrate their use to prepare specimen-specific models of caudal rat vertebrae. We evaluate the algorithms by measuring the distance between target and morphed geometries and by comparing response to axial loading simulated with finite element (FE) methods. First a traditional reconstruction process based on microCT was used to obtain two natural specimen-specific FE models. Next, the two morphing algorithms were used to compute mappings from the surface of one model, the source, to the other, the target, and to use this mapping to morph the source mesh to produce a target mesh. The microCT images were then used to assign element-specific material properties. In AW the mappings were obtained by wrapping the source and target surfaces with an auxiliary triangulated surface. In ML, landmarks were manually placed on corresponding locations on the surfaces of both source and target. Both morphing algorithms were successful in reproducing the shape of the target vertebra with a median distance between natural and morphed models of 18.8 and 32.2 microm, respectively, for AW and ML. Whereas AW-morphing produced a surface more closely resembling that of the target, ML guaranteed correspondence of the landmark locations between source and target. Morphing preserved the quality of the mesh producing models suitable for FE simulation. Moreover, there were only minor differences between natural and morphed models in predictions of deformation, strain and stress. We therefore conclude that

  1. A validated method for the quantitation of 1,1-difluoroethane using a gas in equilibrium method of calibration.

    Science.gov (United States)

    Avella, Joseph; Lehrer, Michael; Zito, S William

    2008-10-01

    1,1-Difluoroethane (DFE), also known as Freon 152A, is a member of a class of compounds known as halogenated hydrocarbons. A number of these compounds have gained notoriety because of their ability to induce rapid onset of intoxication after inhalation exposure. Abuse of DFE has necessitated development of methods for its detection and quantitation in postmortem and human performance specimens. Furthermore, methodologies applicable to research studies are required as there have been limited toxicokinetic and toxicodynamic reports published on DFE. This paper describes a method for the quantitation of DFE using a gas chromatography-flame-ionization headspace technique that employs solventless standards for calibration. Two calibration curves using 0.5 mL whole blood calibrators which ranged from A: 0.225-1.350 to B: 9.0-180.0 mg/L were developed. These were evaluated for linearity (0.9992 and 0.9995), limit of detection of 0.018 mg/L, limit of quantitation of 0.099 mg/L (recovery 111.9%, CV 9.92%), and upper limit of linearity of 27,000.0 mg/L. Combined curve recovery results of a 98.0 mg/L DFE control that was prepared using an alternate technique was 102.2% with CV of 3.09%. No matrix interference was observed in DFE enriched blood, urine or brain specimens nor did analysis of variance detect any significant differences (alpha = 0.01) in the area under the curve of blood, urine or brain specimens at three identical DFE concentrations. The method is suitable for use in forensic laboratories because validation was performed on instrumentation routinely used in forensic labs and due to the ease with which the calibration range can be adjusted. Perhaps more importantly it is also useful for research oriented studies because the removal of solvent from standard preparation eliminates the possibility for solvent induced changes to the gas/liquid partitioning of DFE or chromatographic interference due to the presence of solvent in specimens.

  2. 21 CFR 866.2900 - Microbiological specimen collection and transport device.

    Science.gov (United States)

    2010-04-01

    ... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Microbiology Devices... microbiological specimen collection and transport device is a specimen collecting chamber intended for medical...

  3. Quantitative autoradiography of alpha particle emission in geo-materials using the Beaver™ system

    International Nuclear Information System (INIS)

    Sardini, Paul; Angileri, Axel; Descostes, Michael; Duval, Samuel; Oger, Tugdual; Patrier, Patricia; Rividi, Nicolas; Siitari-Kauppi, Marja; Toubon, Hervé; Donnard, Jérôme

    2016-01-01

    In rocks or artificial geo-materials, radioactive isotopes emitting alpha particles are dispersed according to the mineralogy. At hand specimen scale, the achievement of quantitative chemical mapping of these isotopes takes on a specific importance. Knowledge of the distribution of the uranium and thorium series radionuclides is of prime interest to several disciplines, from the geochemistry of uranium deposits, to the dispersion of uranium mill tailings in the biosphere. The disequilibrium of these disintegration chains is also commonly used for dating. However, some prime importance isotopes, such as 226 Ra, are complicated to localize in geo-materials. Because of its high specific activity, 226 Ra is found in very low concentrations (~ppq), preventing its accurate localization in rock forming minerals. This paper formulates a quantitative answer to the following question: at hand specimen scale, how can alpha emitters in geo-materials be mapped quantitatively? In this study, we tested a new digital autoradiographic method (called the Beaver™) based on a Micro Patterned Gaseous Detector (MPGD) in order to quantitatively map alpha emission at the centimeter scale rock section. Firstly, for two thin sections containing U-bearing minerals at secular equilibrium, we compared the experimental and theoretical alpha count rates, measured by the Beaver™ and calculated from the uranium content, respectively. We found that they are very similar. Secondly, for a set of eight homemade standards made up of a mixture of inactive sand and low-radioactivity mud, we compared the count rates obtained by the Beaver™ and by an alpha spectrometer. The results indicate (i) a linearity between both count rates, and (ii) that the count obtained by the Beaver™ can be estimated from the count obtained by the alpha spectrometry using a factor of 0.82.

  4. Quantitative autoradiography of alpha particle emission in geo-materials using the Beaver™ system

    Energy Technology Data Exchange (ETDEWEB)

    Sardini, Paul; Angileri, Axel [IC2MP Equipe HydrASA, 6 Rue Michel Brunet, B35, TSA 51106 Poitiers Cedex 9 (France); Descostes, Michael [AREVA Mines, R& D Department, Paris (France); Duval, Samuel; Oger, Tugdual [AI4R SAS, Nantes (France); Patrier, Patricia [IC2MP Equipe HydrASA, 6 Rue Michel Brunet, B35, TSA 51106 Poitiers Cedex 9 (France); Rividi, Nicolas [Service Camparis, Université Pierre et Marie Curie, Paris (France); Siitari-Kauppi, Marja [Radiochemistry Laboratory, University of Helsinki, Helsinki (Finland); Toubon, Hervé [AREVA Mines, R& D Department, Paris (France); Donnard, Jérôme [AI4R SAS, Nantes (France)

    2016-10-11

    In rocks or artificial geo-materials, radioactive isotopes emitting alpha particles are dispersed according to the mineralogy. At hand specimen scale, the achievement of quantitative chemical mapping of these isotopes takes on a specific importance. Knowledge of the distribution of the uranium and thorium series radionuclides is of prime interest to several disciplines, from the geochemistry of uranium deposits, to the dispersion of uranium mill tailings in the biosphere. The disequilibrium of these disintegration chains is also commonly used for dating. However, some prime importance isotopes, such as {sup 226}Ra, are complicated to localize in geo-materials. Because of its high specific activity, {sup 226}Ra is found in very low concentrations (~ppq), preventing its accurate localization in rock forming minerals. This paper formulates a quantitative answer to the following question: at hand specimen scale, how can alpha emitters in geo-materials be mapped quantitatively? In this study, we tested a new digital autoradiographic method (called the Beaver™) based on a Micro Patterned Gaseous Detector (MPGD) in order to quantitatively map alpha emission at the centimeter scale rock section. Firstly, for two thin sections containing U-bearing minerals at secular equilibrium, we compared the experimental and theoretical alpha count rates, measured by the Beaver™ and calculated from the uranium content, respectively. We found that they are very similar. Secondly, for a set of eight homemade standards made up of a mixture of inactive sand and low-radioactivity mud, we compared the count rates obtained by the Beaver™ and by an alpha spectrometer. The results indicate (i) a linearity between both count rates, and (ii) that the count obtained by the Beaver™ can be estimated from the count obtained by the alpha spectrometry using a factor of 0.82.

  5. Standard practice for fracture testing with surface-crack tension specimens

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers the design, preparation, and testing of surface-crack tension (SCT) specimens. It relates specifically to testing under continuously increasing force and excludes cyclic and sustained loadings. The quantity determined is the residual strength of a specimen having a semielliptical or circular-segment fatigue crack in one surface. This value depends on the crack dimensions and the specimen thickness as well as the characteristics of the material. 1.2 Metallic materials that can be tested are not limited by strength, thickness, or toughness. However, tests of thick specimens of tough materials may require a tension test machine of extremely high capacity. The applicability of this practice to nonmetallic materials has not been determined. 1.3 This practice is limited to specimens having a uniform rectangular cross section in the test section. The test section width and length must be large with respect to the crack length. Crack depth and length should be chosen to suit the ultimate pu...

  6. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    Energy Technology Data Exchange (ETDEWEB)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M. [Charite, Berlin (Germany). Radiology

    2012-07-15

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  7. Influence of thermal conditioning media on Charpy specimen test temperature

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Swain, R.L.; Berggren, R.G.

    1989-01-01

    The Charpy V-notch (CVN) impact test is used extensively for determining the toughness of structural materials. Research programs in many technologies concerned with structural integrity perform such testing to obtain Charpy energy vs temperature curves. American Society for Testing and Materials Method E 23 includes rather strict requirements regarding determination and control of specimen test temperature. It specifies minimum soaking times dependent on the use of liquids or gases as the medium for thermally conditioning the specimen. The method also requires that impact of the specimen occur within 5 s removal from the conditioning medium. It does not, however, provide guidance regarding choice of conditioning media. This investigation was primarily conducted to investigate the changes in specimen temperature which occur when water is used for thermal conditioning. A standard CVN impact specimen of low-alloy steel was instrumented with surface-mounted and embedded thermocouples. Dependent on the media used, the specimen was heated or cooled to selected temperatures in the range -100 to 100 degree C using cold nitrogen gas, heated air, acetone and dry ice, methanol and dry ice, heated oil, or heated water. After temperature stabilization, the specimen was removed from the conditioning medium while the temperatures were recorded four times per second from all thermocouples using a data acquisition system and a computer. The results show that evaporative cooling causes significant changes in the specimen temperatures when water is used for conditioning. Conditioning in the other media did not result in such significant changes. The results demonstrate that, even within the guidelines of E 23, significant test temperature changes can occur which may substantially affect the Charpy impact test results if water is used for temperature conditioning. 7 refs., 11 figs

  8. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions.

    Science.gov (United States)

    Schmachtenberg, C; Engelken, F; Fischer, T; Bick, U; Poellinger, A; Fallenberg, E M

    2012-07-01

    Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. © Georg Thieme Verlag KG Stuttgart · New York.

  9. Intraoperative specimen radiography in patients with nonpalpable malignant breast lesions

    International Nuclear Information System (INIS)

    Schmachtenberg, C.; Engelken, F.; Fischer, T.; Bick, U.; Poellinger, A.; Fallenberg, E.M.

    2012-01-01

    Purpose: Specimen mammography of nonpalpable wire-localized breast lesions is the standard in breast-conserving surgery. The aim of this study was to evaluate the reliability of intraoperative 2-view specimen mammography in different cancer types. Materials and Methods: After ethics approval, 3 readers retrospectively evaluated margins on 266 2-view specimen radiographs. They determined the closest margin and the orientation. The results were correlated with the histopathology (intra-class correlation coefficient [ICC] and contingency coefficient [CC]) and compared (Wilcoxon test). Results: Invasive ductal carcinoma (IDC) with ductal carcinoma in situ (DCIS) was present in 115 (43 %), IDC in 75 (28 %), invasive lobular carcinoma (ILC) in 57 (22 %) and rare cancers (CA) in 19 specimens (7 %). The sensitivity/specificity and positive/negative predictive value (P/NPV) of specimen mammography were 0.50/0.86 and 0.86/0.50 for CA, 0.42/0.68 and 0.48/0.63 for IDC, 0.36/0.81 and 0.69/0.51 for ILC, and 0.22/0.78 and 0.68/0.32 for IDC+DCIS. Readers correctly identified the orientation of the closest margin in at least one view in an average of 149 specimens (56 %). CCs were between 0.680 (IDC) and 0.912 (CA), suggesting a moderate correlation between radiographic and histological orientation. The correlations were worse for the radiographic and histological distances, with ICC ranging from 0.238 (ILC) to 0.475 (CA). The Wilcoxon test revealed overestimation of the radiographic margins compared to the histological ones for DCIS. Conclusion: Our results suggest that specimen radiography has relatively good overall specificity and good PPV, while the sensitivity and NPV are low for DCIS. A negative result on specimen radiography does not rule out histologically involved margins. (orig.)

  10. Feasible pickup from intact ossicular chain with floating piezoelectric microphone.

    Science.gov (United States)

    Kang, Hou-Yong; Na, Gao; Chi, Fang-Lu; Jin, Kai; Pan, Tie-Zheng; Gao, Zhen

    2012-02-22

    Many microphones have been developed to meet with the implantable requirement of totally implantable cochlear implant (TICI). However, a biocompatible one without destroying the intactness of the ossicular chain still remains under investigation. Such an implantable floating piezoelectric microphone (FPM) has been manufactured and shows an efficient electroacoustic performance in vitro test at our lab. We examined whether it pick up sensitively from the intact ossicular chain and postulated whether it be an optimal implantable one. Animal controlled experiment: five adult cats (eight ears) were sacrificed as the model to test the electroacoustic performance of the FPM. Three groups were studied: (1) the experiment group (on malleus): the FPM glued onto the handle of the malleus of the intact ossicular chains; (2) negative control group (in vivo): the FPM only hung into the tympanic cavity; (3) positive control group (Hy-M30): a HiFi commercial microphone placed close to the site of the experiment ear. The testing speaker played pure tones orderly ranged from 0.25 to 8.0 kHz. The FPM inside the ear and the HiFi microphone simultaneously picked up acoustic vibration which recorded as .wav files to analyze. The FPM transformed acoustic vibration sensitively and flatly as did the in vitro test across the frequencies above 2.0 kHz, whereas inefficiently below 1.0 kHz for its overloading mass. Although the HiFi microphone presented more efficiently than the FPM did, there was no significant difference at 3.0 kHz and 8.0 kHz. It is feasible to develop such an implantable FPM for future TICIs and TIHAs system on condition that the improvement of Micro Electromechanical System and piezoelectric ceramic material technology would be applied to reduce its weight and minimize its size.

  11. Feasible pickup from intact ossicular chain with floating piezoelectric microphone

    Directory of Open Access Journals (Sweden)

    Kang Hou-Yong

    2012-02-01

    Full Text Available Abstract Objectives Many microphones have been developed to meet with the implantable requirement of totally implantable cochlear implant (TICI. However, a biocompatible one without destroying the intactness of the ossicular chain still remains under investigation. Such an implantable floating piezoelectric microphone (FPM has been manufactured and shows an efficient electroacoustic performance in vitro test at our lab. We examined whether it pick up sensitively from the intact ossicular chain and postulated whether it be an optimal implantable one. Methods Animal controlled experiment: five adult cats (eight ears were sacrificed as the model to test the electroacoustic performance of the FPM. Three groups were studied: (1 the experiment group (on malleus: the FPM glued onto the handle of the malleus of the intact ossicular chains; (2 negative control group (in vivo: the FPM only hung into the tympanic cavity; (3 positive control group (Hy-M30: a HiFi commercial microphone placed close to the site of the experiment ear. The testing speaker played pure tones orderly ranged from 0.25 to 8.0 kHz. The FPM inside the ear and the HiFi microphone simultaneously picked up acoustic vibration which recorded as .wav files to analyze. Results The FPM transformed acoustic vibration sensitively and flatly as did the in vitro test across the frequencies above 2.0 kHz, whereas inefficiently below 1.0 kHz for its overloading mass. Although the HiFi microphone presented more efficiently than the FPM did, there was no significant difference at 3.0 kHz and 8.0 kHz. Conclusions It is feasible to develop such an implantable FPM for future TICIs and TIHAs system on condition that the improvement of Micro Electromechanical System and piezoelectric ceramic material technology would be applied to reduce its weight and minimize its size.

  12. Imaging of concrete specimens using inverse synthetic aperture radar

    International Nuclear Information System (INIS)

    Rhim, Hong C.; Buyukozturk, Oral

    2000-01-01

    Radar Measurement results of laboratory size concrete specimens are presented in this paper. The purpose of this research work is to study various aspects of the radar method in an effort to develop an improved radar system for nondestructive testing of concrete structures. The radar system used for the study is an Inverse Synthetic Aperture Radar (ISAR), which is capable of transmitting microwaves at three different frequency ranges of 2-3.4, 3.4-5.8, and 8-12 GHz. Radar measurement setup is such that the radar is locates 14.4 m away from a concrete target to satisfy a far-field criterion. The concrete target is rotated for 20 degrees during the measurements for the generation of two-dimensional (cross-range) imagery. Concrete targets used for the measurements have the dimensions of 305 mm (width)x305 mm (height)x92 mm (thickness) with different inside configurations. Comparisons are made for dry and wet specimens, specimens with and without inclusions. Each specimen is made to model various situations that a concrete structure can have in reality. Results show that center frequency, frequency bandwidth, and polarization of the incident wave have different effects on identifying the thickness or inclusions inside concrete specimens. Results also suggest that a certain combination of measurement parameters is suitable for a specific application area. Thus, measurement parameters can be optimized for a specific problem. The findings are presented and discussed in details in the paper. Signal processing schemes implemented for imaging of the specimens are also discussed

  13. Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe.

    Science.gov (United States)

    Takahashi, J; Kawakami, K; Raabe, D

    2017-04-01

    The difference in quantitative analysis performance between the voltage-mode and laser-mode of a local electrode atom probe (LEAP3000X HR) was investigated using a Fe-Cu binary model alloy. Solute copper atoms in ferritic iron preferentially field evaporate because of their significantly lower evaporation field than the matrix iron, and thus, the apparent concentration of solute copper tends to be lower than the actual concentration. However, in voltage-mode, the apparent concentration was higher than the actual concentration at 40K or less due to a detection loss of matrix iron, and the concentration decreased with increasing specimen temperature due to the preferential evaporation of solute copper. On the other hand, in laser-mode, the apparent concentration never exceeded the actual concentration, even at lower temperatures (20K), and this mode showed better quantitative performance over a wide range of specimen temperatures. These results indicate that the pulsed laser atom probe prevents both detection loss and preferential evaporation under a wide range of measurement conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Calculation of ion currents across the inner membrane of functionally intact mitochondria

    Science.gov (United States)

    Kane, Daniel A; Pavlov, Evgeny V

    2013-01-01

    Mitochondrial ion transport systems play a central role in cell physiology. Rates of Ca2+ and K+ transport across the inner mitochondrial membrane have been derived from the measurement of ion accumulation over time within functional isolated mitochondria or mitochondria of cultured cells. Alternatively, the electrical currents generated by ionic flux have been directly measured in purified and swollen mitochondrial samples (mitoplasts) or reconstituted channels, and typically range from 1 pA to several 100s pA. However, the direct electrophysiological approach necessarily requires extensive processing of the mitochondria prior to measurement, which can only be performed on isolated mitoplasts. To compare rates of mitochondrial ion transport measured in electrophysiological experiments to those measured in intact mitochondria and cells, we converted published rates of mitochondrial ion uptake into units of ionic current. We estimate that for monovalent ions, uptake by intact mitochondria at the rate of 1 nmol ∙ mg−1 protein ∙ min−1 is equivalent to 0.2 fA of current per whole single mitochondrion (0.4 fA for divalent ions). In intact mitochondria, estimated rates of electrogenic cation uptake are limited to 1–100 fA of integral current per single mitochondrion. These estimates are orders of magnitude lower than the currents through mitochondrial channels directly measured via patch-clamp or artificial lipid bilayer approaches. PMID:24037064

  15. Development of piezoelectric ceramics driven fatigue testing machine for small specimens

    International Nuclear Information System (INIS)

    Saito, S.; Kikuchi, K.; Onishi, Y.; Nishino, T.

    2002-01-01

    A new fatigue testing machine with piezoelectric ceramics actuators was developed and a prototype was manufactured for high-cycle fatigue tests with small specimens. The machine has a simple mechanism and is compact. These features make it easy to set up and to maintain the machine in a hot cell. The excitation of the actuator can be transmitted to the specimen using a lever-type testing jig. More than 100 μm of displacement could be prescribed precisely to the specimen at a frequency of 50 Hz. This was sufficient performance for high-cycle bend fatigue tests on specimens irradiated at the SINQ target in Paul Scherrer Institute. The relationship of a displacement applied to the specimen and the strain of the necking part were obtained by experimental methods and by finite element method (FEM) calculations. Both results showed good agreement. This fact makes it possible to evaluate the strain of irradiated specimens by FEM simulations

  16. Examination of the fatigue life under combined loading of specimens

    Directory of Open Access Journals (Sweden)

    Fojtík F.

    2008-11-01

    Full Text Available This contribution describes experimental results under combined loading of specimens manufactured from common construction steel 11523. Specimens were gradually loaded by amplitude of the torque, then by combination of torque and tension prestress. The last set of specimens was loaded in combination of torque and inner overpressure. To obtain the required input values the stress-strain analysis of specimens by finite element method in software Ansys was performed within the last experiment. For evaluation of the results the Fuxa's criterion was applied. The performed experiments and their results embody a good agreement with bellow mentioned conjugated strength criterion. The experiments were performed on reconstructed testing machine equipped by pressure chamber.

  17. Transport of beta-aminopropionitrile through intact skin or scar tissue

    International Nuclear Information System (INIS)

    Gibeault, J.D.; Cravens, R.B. Jr.; Chvapil, M.

    1989-01-01

    A lathyrogen, [ 14 C]aminopropionitrile (beta APN), was administered to 34 rats either in K-Y jelly or saline vehicles onto intact shaven skin or onto a healed splinted deep excision wound. The dynamics of beta APN transport and content in the skin or repair tissue was observed after 2, 5, 8, and 24 hr of topical administration. The repair tissue quickly absorbed the lathyrogen and reached maximum at the 2-hr sampling. The content of beta APN in the repair tissue was twice as high as that in K-Y jelly vehicle and remained high and stable for at least 24 hr only when beta APN was administered through a saline vehicle. The transport of beta APN through intact skin, irrespective of the vehicle tested, was slow and continuously increased. The study showed that almost 20% of the beta APN administered onto the wounded skin area was transported into the repair tissue within 2 hr. We suggest that, due to the absence of epidermal stratum corneum from the repair tissue, drugs, such as beta APN, penetrate quickly into the wound

  18. Improved PID control for triaxial testing liquefied specimen

    DEFF Research Database (Denmark)

    Sabaliauskas, Tomas; Ibsen, Lars Bo

    Using a frictionless triaxial apparatus, sand specimens can be tested at relatively high axial strains, even while liquefying. However, liquefying specimens have extremely nonlinear stiffness, thus standard PID control does not perform well. To maintain control over applied loads, the PID...... controller was modified to adapt to disturbed soil states. The proposed methods expand the scope of testing towards options which are otherwise inaccessible by triaxial testing....

  19. Failed PCR of Ganoderma type specimens affects nomenclature.

    Science.gov (United States)

    Paterson, R R M; Lima, N

    2015-06-01

    The nomenclature of Ganoderma used as a Chinese medicine is debated. A group of researchers could not amplify the DNA of type specimens and concluded the DNA was degraded irreparably. New topotypes were used as the type specimens which was premature. The use of internal amplification controls is recommended to determine if other factors were involved as alternative explanations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Enzymatic methylation of band 3 anion transporter in intact human erythrocytes

    International Nuclear Information System (INIS)

    Lou, L.L.; Clarke, S.

    1987-01-01

    Band 3, the anion transport protein of erythrocyte membranes, is a major methyl-accepting substrate of the intracellular erythrocyte protein carboxyl methyltransferase (S-adenosyl-L-methionine: protein-D-aspartate O-methyltransferase; EC 2.1.1.77). The localization of methylation sites in intact cells by analysis of proteolytic fragments indicated that sites were present in the cytoplasmic N-terminal domain as well as the membranous C-terminal portion of the polypeptide. The amino acid residues that serve as carboxyl methylation sites of the erythrocyte anion transporter were also investigated. 3 H-Methylated band 3 was purified from intact erythrocytes incubated with L-[methyl- 3 H]methionine and from trypsinized and lysed erythrocytes incubated with S-adenosyl-L-[methyl- 3 H]methionine. After proteolytic digestion with carboxypeptidase Y, D-aspartic acid beta-[ 3 H]methyl ester was isolated in low yields (9% and 1%, respectively) from each preparation. The bulk of the radioactivity was recovered as [ 3 H]methanol, and the amino acid residue(s) originally associated with these methyl groups could not be determined. No L-aspartic acid beta-[ 3 H]methyl ester or glutamyl gamma-[ 3 H]methyl ester was detected. The formation of D-aspartic acid beta-[ 3 H]methyl esters in this protein in intact cells resulted from protein carboxyl methyltransferase activity since it was inhibited by adenosine and homocysteine thiolactone, which increases the intracellular concentration of the potent product inhibitor S-adenosylhomocysteine, and cycloleucine, which prevents the formation of the substrate S-adenosyl-L-[methyl- 3 H]methionine

  1. Monolithic integration of nanoscale tensile specimens and MEMS structures

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet; Kysar, Jeffrey W

    2013-01-01

    Nanoscale materials often have stochastic material properties due to a random distribution of material defects and an insufficient number of defects to ensure a consistent average mechanical response. Current methods to measure the mechanical properties employ MEMS-based actuators. The nanoscale specimens are typically mounted manually onto the load platform, so the boundary conditions have random variations, complicating the experimental measurement of the intrinsic stochasticity of the material properties. Here we show methods for monolithic integration of a nanoscale specimen co-fabricated with the loading platform. The nanoscale specimen is gold with dimensions of ∼40 nm thickness, 350 ± 50 nm width, and 7 μm length and the loading platform is an interdigitated electrode electrostatic actuator. The experiment is performed in a scanning electron microscope and digital image correlation is employed to measure displacements to determine stress and strain. The ultimate tensile strength of the nanocrystalline nanoscale specimen approaches 1 GPa, consistent with measurements made by other nanometer scale sample characterization methods on other material samples at the nanometer scale, as well as gold samples at the nanometer scale. The batch-compatible microfabrication method can be used to create nominally identical nanoscale specimens and boundary conditions for a broad range of materials. (paper)

  2. Increasing the efficiency of digitization workflows for herbarium specimens.

    Science.gov (United States)

    Tulig, Melissa; Tarnowsky, Nicole; Bevans, Michael; Anthony Kirchgessner; Thiers, Barbara M

    2012-01-01

    The New York Botanical Garden Herbarium has been databasing and imaging its estimated 7.3 million plant specimens for the past 17 years. Due to the size of the collection, we have been selectively digitizing fundable subsets of specimens, making successive passes through the herbarium with each new grant. With this strategy, the average rate for databasing complete records has been 10 specimens per hour. With 1.3 million specimens databased, this effort has taken about 130,000 hours of staff time. At this rate, to complete the herbarium and digitize the remaining 6 million specimens, another 600,000 hours would be needed. Given the current biodiversity and economic crises, there is neither the time nor money to complete the collection at this rate.Through a combination of grants over the last few years, The New York Botanical Garden has been testing new protocols and tactics for increasing the rate of digitization through combinations of data collaboration, field book digitization, partial data entry and imaging, and optical character recognition (OCR) of specimen images. With the launch of the National Science Foundation's new Advancing Digitization of Biological Collections program, we hope to move forward with larger, more efficient digitization projects, capturing data from larger portions of the herbarium at a fraction of the cost and time.

  3. Centrifuge-operated specimen staining method and apparatus

    Science.gov (United States)

    Clarke, Mark S. F. (Inventor); Feeback, Daniel L. (Inventor)

    1999-01-01

    A method of staining preselected, mounted specimens of either biological or nonbiological material enclosed within a staining chamber where the liquid staining reagents are applied and removed from the staining chamber using hypergravity as the propelling force. In the preferred embodiment, a spacecraft-operated centrifuge and method of diagnosing biological specimens while in orbit, characterized by hermetically sealing a shell assembly. The assembly contains slide stain apparatus with computer control therefor, the operative effect of which is to overcome microgravity, for example on board an International Space Station.

  4. Proceedings of the international workshop on mechanistic understanding of radionuclide migration in compacted/intact systems

    International Nuclear Information System (INIS)

    Tachi, Yukio; Yui, Mikazu

    2010-03-01

    The international workshop on mechanistic understanding of radionuclide migration in compacted / intact systems was held at ENTRY, JAEA, Tokai on 21st - 23rd January, 2009. This workshop was hosted by Japan Atomic Energy Agency (JAEA) as part of the project on the mechanistic model/database development for radionuclide sorption and diffusion behavior in compacted / intact systems. The overall goal of the project is to develop the mechanistic model / database for a consistent understanding and prediction of migration parameters and its uncertainties for performance assessment of geological disposal of radioactive waste. The objective of the workshop is to integrate the state-of-the-art of mechanistic sorption and diffusion model in compacted / intact systems, especially in bentonite / clay systems, and discuss the JAEA's mechanistic approaches and future challenges, especially the following discussions points; 1) What's the status and difficulties for mechanistic model/database development? 2) What's the status and difficulties for applicability of mechanistic model to the compacted/intact system? 3) What's the status and difficulties for obtaining evidences for mechanistic model? 4) What's the status and difficulties for standardization of experimental methodology for batch sorption and diffusion? 5) What's the uncertainties of transport parameters in radionuclides migration analysis due to a lack of understanding/experimental methodologies, and how do we derive them? This report includes workshop program, overview and materials of each presentation, summary of discussions. (author)

  5. Forest Loss in Protected Areas and Intact Forest Landscapes: A Global Analysis.

    Science.gov (United States)

    Heino, Matias; Kummu, Matti; Makkonen, Marika; Mulligan, Mark; Verburg, Peter H; Jalava, Mika; Räsänen, Timo A

    2015-01-01

    In spite of the high importance of forests, global forest loss has remained alarmingly high during the last decades. Forest loss at a global scale has been unveiled with increasingly finer spatial resolution, but the forest extent and loss in protected areas (PAs) and in large intact forest landscapes (IFLs) have not so far been systematically assessed. Moreover, the impact of protection on preserving the IFLs is not well understood. In this study we conducted a consistent assessment of the global forest loss in PAs and IFLs over the period 2000-2012. We used recently published global remote sensing based spatial forest cover change data, being a uniform and consistent dataset over space and time, together with global datasets on PAs' and IFLs' locations. Our analyses revealed that on a global scale 3% of the protected forest, 2.5% of the intact forest, and 1.5% of the protected intact forest were lost during the study period. These forest loss rates are relatively high compared to global total forest loss of 5% for the same time period. The variation in forest losses and in protection effect was large among geographical regions and countries. In some regions the loss in protected forests exceeded 5% (e.g. in Australia and Oceania, and North America) and the relative forest loss was higher inside protected areas than outside those areas (e.g. in Mongolia and parts of Africa, Central Asia, and Europe). At the same time, protection was found to prevent forest loss in several countries (e.g. in South America and Southeast Asia). Globally, high area-weighted forest loss rates of protected and intact forests were associated with high gross domestic product and in the case of protected forests also with high proportions of agricultural land. Our findings reinforce the need for improved understanding of the reasons for the high forest losses in PAs and IFLs and strategies to prevent further losses.

  6. Intact proinsulin and beta-cell function in lean and obese subjects with and without type 2 diabetes

    DEFF Research Database (Denmark)

    Røder, M E; Dinesen, B; Hartling, S G

    1999-01-01

    , total proinsulin immunoreactivity (PIM), intact insulin, and C-peptide (by radioimmunoassay) by specific enzyme-linked immunosorbent assays in the fasting state and during a 120-min glucagon (1 mg i.v.) stimulation test. Lean (BMI 23.5 +/- 0.3 kg/m2) (LD) and obese (30.1 +/- 0.4 kg/m2) (OD) type 2...... diabetic patients matched for fasting glucose (10.2 +/- 0.6 vs. 10.3 +/- 0.4 mmol/l) were compared with age- and BMI-matched lean (22.4 +/- 0.6 kg/m2) (LC) and obese (30.8 +/- 0.9 kg/m2) (OC) normal control subjects. RESULTS: Diabetic patients (LD vs. LC and OD vs. OC) had elevated fasting levels of intact......, most pronounced in the lean group. The ratio of intact proinsulin to PIM was higher in diabetic patients after stimulation in both LD versus LC: 32 +/- 3 vs. 23 +/- 2%, and OD versus OC: 28 +/- 4 vs. 16 +/- 2%, both P obese normal subjects, intact proinsulin/PIM was lower both in the fasting...

  7. Fracture toughness measurements with subsize disk compact specimens

    International Nuclear Information System (INIS)

    Alexander, D.J.

    1994-01-01

    Special fixtures and test methods have been developed for testing small disk compact specimens (1.25 mm diam by 4.6 mm thick). Specimens of European type 316L austenitic stainless steel were irradiated to damage levels of about 3 dpa at nominal irradiation temperatures of either 90 or 250 C and tested over a temperature range from 20 to 250 C. Results show that irradiation to this dose level at these temperatures reduces the fracture toughness but the toughness remains quite high. The toughness decreases as the test temperature increases. Irradiation at 250 C is more damaging than at 90 C, causing larger decreases in the fracture toughness. The testing shows that it is possible to generate useful fracture toughness data with a small disk compact specimens

  8. Computer vision applied to herbarium specimens of German trees: testing the future utility of the millions of herbarium specimen images for automated identification.

    Science.gov (United States)

    Unger, Jakob; Merhof, Dorit; Renner, Susanne

    2016-11-16

    Global Plants, a collaborative between JSTOR and some 300 herbaria, now contains about 2.48 million high-resolution images of plant specimens, a number that continues to grow, and collections that are digitizing their specimens at high resolution are allocating considerable recourses to the maintenance of computer hardware (e.g., servers) and to acquiring digital storage space. We here apply machine learning, specifically the training of a Support-Vector-Machine, to classify specimen images into categories, ideally at the species level, using the 26 most common tree species in Germany as a test case. We designed an analysis pipeline and classification system consisting of segmentation, normalization, feature extraction, and classification steps and evaluated the system in two test sets, one with 26 species, the other with 17, in each case using 10 images per species of plants collected between 1820 and 1995, which simulates the empirical situation that most named species are represented in herbaria and databases, such as JSTOR, by few specimens. We achieved 73.21% accuracy of species assignments in the larger test set, and 84.88% in the smaller test set. The results of this first application of a computer vision algorithm trained on images of herbarium specimens shows that despite the problem of overlapping leaves, leaf-architectural features can be used to categorize specimens to species with good accuracy. Computer vision is poised to play a significant role in future rapid identification at least for frequently collected genera or species in the European flora.

  9. Maintaining respect and fairness in the usage of stored shared specimens.

    Science.gov (United States)

    Mduluza, Takafira; Midzi, Nicholas; Duruza, Donold; Ndebele, Paul

    2013-01-01

    Every year, research specimens are shipped from one institution to another as well as across national boundaries. A significant proportion of specimens move from poor to rich countries. Concerns are always raised on the future usage of the stored specimens shipped to research institutions from developing countries. Creating awareness of the processes is required in all sectors involved in biomedical research. To maintain fairness and respect in sharing biomedical specimens and research products requires safeguarding by Ethics Review Committees in both provider and recipient institutions. Training in basic ethical principles in research is required to all sectors involved in biomedical research so as to level up the research playing field. By agreeing to provide specimens, individuals and communities from whom samples are collected would have placed their trust and all ensuing up-keep of the specimens to the researchers. In most collaborative set-up, laid down material transfer agreements are negotiated and signed before the shipment of specimens. Researchers, research ethics committees (RECs) and institutions in the countries of origin are supposed to serve as overseers of the specimens. There is need to advocate for honesty in sample handling and sharing, and also need to oversee any written commitments by researchers, RECs and institutions at source as well as in recipient institution. Commitments from source RECs and Institutional Review Boards (IRBs) and in the receiving institution on overseeing the future usage of stored specimens are required; including the ultimate confirmation abiding by the agreement. Training in ethical issues pertaining to sample handling and biomedical research in general is essential at all levels of academic pursuit. While sharing of biological specimens and research data demands honesty and oversight by ethical regulatory agents from both institutions in developing country and recipient institutions in developed countries. Archiving

  10. Protein methylation reactions in intact pea chloroplasts

    International Nuclear Information System (INIS)

    Niemi, K.J.

    1989-01-01

    Post-translational protein methylation was investigated in Pisum sativum chloroplasts. Intact pea chloroplasts were incubated with ( 3 H-methyl)-S-adenosylmethionine under various conditions. The chloroplasts were then separated into stromal and thylakoid fractions and analyzed for radioactivity transferred to protein. Light enhanced the magnitude of labeling in both fractions. One thylakoid polypeptide with an apparent molecular mass of 43 kDa was labeled only in the light. Several other thylakoid and stromal proteins were labeled in both light and dark-labeling conditions. Both base-labile methylation, carboxy-methylesters and base-stable groups, N-methylations were found. Further characterization of the methyl-transfer reactions will be presented

  11. 50 CFR 14.24 - Scientific specimens.

    Science.gov (United States)

    2010-10-01

    ..., POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE AND PLANTS... international mail system. Provided, that this exception will not apply to any specimens or parts thereof taken...

  12. Evaluation of A-1 reactor heavy-water calandria specimens

    International Nuclear Information System (INIS)

    Brumovsky, M.

    1976-01-01

    Container chains with surveillance specimens were placed in two special channels of the core peripheral part to test changes in mechanical properties due to reactor operation of caisson tube material. The specimens were made from the caisson tube material and placed by eight pieces on the outer surface of the containers. The first removed specimens were tested for corrosion losses, tensile strength, and fractured surfaces were then assessed. The changes in strength properties were found to be similar in both base material and welded joints. The corrosion film on surveillance specimens did not practically affect strength properties nor ductility. It was found that the Al-Mg-Si alloy used for the heavy water vessel caisson tubes following stabilization annealing was fully stable at operating temperatures of up to 100 degC. Slio.ht changes in properties can be attributed to the effect of a high neutron dose. Thus, the high radiation and temperature stability of the alloy was confirmed. (O.K.)

  13. Characterization of the anion sensitive ATPase in intact vacuoles of Kalanchoe diagremontiana

    Energy Technology Data Exchange (ETDEWEB)

    Kobza, J.; Uribe, E.G.

    1986-04-01

    A method for the isolation of intact vacuoles from K. daigremontiana was developed which produced high yields of relatively pure vacuoles as determined by marker enzyme contamination. Upon isolation, the vacuoles were stabilized by the inclusion of 5% (w/v) ficoll. Enzyme activity was insensitive to vanadate and azide but was strongly inhibited by DCCD. Enzyme activity was strictly dependent on the inclusion of Mg/sup 2 +/ and was stimulated by anions as depicted by the series, NO/sub 3//sup -/ < Br/sup -/ < SO/sub 4//sup -/ < HCO/sub 3//sup -/ < Cl/sup -/. It was found that in intact vacuoles the ATPase activity was stimulated by phosphate to a level equivalent to that found with the chloride. The enzyme exhibited Michaelis-Menten kinetics with a Km for Mg-ATP complex of 0.51 mM.

  14. Review of forensically important entomological specimens collected from human cadavers in Malaysia (2005-2010).

    Science.gov (United States)

    Kavitha, Rajagopal; Nazni, Wasi Ahmad; Tan, Tian Chye; Lee, Han Lim; Azirun, Mohd Sofian

    2013-07-01

    Forensic entomological specimens collected from human decedents during crime scene investigations in Malaysia in the past 6 years (2005-2010) are reviewed. A total of 80 cases were recorded and 93 specimens were collected. From these specimens, 10 species of cyclorrphagic flies were identified, consisting of Chrysomya rufifacies (Macquart) -38 specimens (40.86%), Chrysomya megacephala (Fabricius) -36 specimens (38.70%), Chrysomya villeneuvi (Patton) -2 specimens (2.15%), Chrysomya nigripes (Aubertin) -2 specimens (2.15%), Chrysomya pinguis (Walker) -1 specimen (1.08%), Hermetia illucens (Linnaeus) -1 specimen (1.08%), Hemipyrellia liguriens (Wiedemann) -5 specimens (5.37%), Synthesiomyia nudiseta (Wulp) -1 specimen (1.08%), Megaselia scalaris (Loew)-1 specimen (1.08%) and Sarcophaga ruficornis (Fabricius) -4 specimens (4.30%). In two specimens (2.15%), the maggots were not identifiable. Ch. megacephala and Ch. rufifacies were the commonest species found in human decedents from three different ecological habitats. S. nudiseta is an uncommon species found only on human cadavers from indoors. A total of 75 cases (93.75%) had a single fly infestation and 5 cases (6.25%) had double fly infestation. In conclusion, although large numbers of fly species were found on human decedents, the predominant species are still those of Chrysomya. Copyright © 2013 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  15. Microseismic Analysis of Fracture of an Intact Rock Asperity Traversing a Sawcut Fault

    Science.gov (United States)

    Mclaskey, G.; Lockner, D. A.

    2017-12-01

    Microseismic events carry information related to stress state, fault geometry, and other subsurface properties, but their relationship to large and potentially damaging earthquakes is not well defined. We conducted laboratory rock mechanics experiments that highlight the interaction between a sawcut fault and an asperity composed of an intact rock "pin". The sample is a 76 mm diameter cylinder of Westerly granite with a 21 mm diameter cylinder (the pin) of intact Westerly granite that crosses the sawcut fault. Upon loading to 80 MPa in a triaxial machine, we first observed a slip event that ruptured the sawcut fault, slipped about 35 mm, but was halted by the rock pin. With continued loading, the rock pin failed in a swarm of thousands of M -7 seismic events similar to the localized microcracking that occurs during the final fracture nucleation phase in an intact rock sample. Once the pin was fractured to a critical point, it permitted complete rupture events on the sawcut fault (stick-slip instabilities). No seismicity was detected on the sawcut fault plane until the pin was sheared. Subsequent slip events were preceded by 10s of foreshocks, all located on the fault plane. We also identified an aseismic zone on the fault plane surrounding the fractured rock pin. A post-mortem analysis of the sample showed a thick gouge layer where the pin intersected the fault, suggesting that this gouge propped open the fault and prevented microseismic events in its vicinity. This experiment is an excellent case study in microseismicity since the events separate neatly into three categories: slip on the sawcut fault, fracture of the intact rock pin, and off-fault seismicity associated with pin-related rock joints. The distinct locations, timing, and focal mechanisms of the different categories of microseismic events allow us to study how their occurrence is related to the mechanics of the deforming rock.

  16. INTEGRATED QUANTITATIVE ASSESSMENT OF CHANGES IN NEURO-ENDOCRINE-IMMUNE COMPLEX AND METABOLISM IN RATS EXPOSED TO ACUTE COLD-IMMOBILIZATION STRESS

    Directory of Open Access Journals (Sweden)

    Sydoruk O Sydoruk

    2016-09-01

        Abstracts Background. It is known that the reaction of the neuroendocrine-immune complex to acute and chronic stress are different. It is also known about sex differences in stress reactions. Previously we have been carry out integrated quantitative estimation of neuroendocrine and immune responses to chronic restraint stress at male rats. The purpose of this study - to carry out integrated quantitative estimation of neuroendocrine, immune and metabolic responses to acute stress at male and female rats. Material and research methods. The experiment is at 58 (28 male and 30 female white rats Wistar line weighing 170-280 g (Mean=220 g; SD=28 g. The day after acute (water immersion restraint stress determined HRV, endocrine, immune and metabolic parameters as well as gastric mucosa injuries and comparing them with parameters of intact animals. Results. Acute cold-immobilization stress caused moderate injuries the stomach mucosa as erosions and ulcers. Among the metabolic parameters revealed increased activity Acid Phosphatase, Asparagine and Alanine Aminotranspherase as well as Creatinephosphokinase. It was also found to reduce plasma Testosterone as well as serum Potassium and Phosphate probably due to increased Parathyrine and Mineralocorticoid activity and Sympathotonic shift of sympatho-vagal balance. Integrated quantitative measure manifestations of Acute Stress as mean of modules of Z-Scores makes for 10 metabolic parameters 0,75±0,10 σ and for 8 neuro-endocrine parameters 0,40±0,07 σ. Among immune parameters some proved resistant to acute stress factors, while 10 significant suppressed and 12 activated. Integrated quantitative measure poststressory changes makes 0,73±0,08 σ. Found significant differences integrated status intact males and females, whereas after stress differences are insignificant. Conclusion. The approach to integrated quantitative assessment of neuroendocrine-immune complex and metabolism may be useful for testing the

  17. Optimization of tensile method and specimen geometry in modified ring tensile test

    International Nuclear Information System (INIS)

    Kitano, Koji; Fuketa, Toyoshi; Sasajima, Hideo; Uetsuka, Hiroshi

    2001-03-01

    Several techniques in ring tensile test are proposed in order to evaluate mechanical properties of cladding under hoop loading condition caused by pellet/cladding mechanical interaction (PCMI). In the modified techniques, variety of tensile methods and specimen geometry are being proposed in order to limit deformation within the gauge section. However, the tensile method and the specimen geometry were not determined in the modified techniques. In the present study, we have investigated the tensile method and the specimen geometry through finite element method (FEM) analysis of specimen deformation and tensile test on specimens with various gauge section geometries. In using two-piece tensile tooling, the mechanical properties under hoop loading condition can be correctly evaluated when deformation part (gauge section) is put on the top of a half-mandrel, and friction between the specimen and the half-mandrel is reduced with Teflon tape. In addition, we have shown the optimum specimen geometry for PWR 17 by 17 type cladding. (author)

  18. Patient safety in the clinical laboratory: a longitudinal analysis of specimen identification errors.

    Science.gov (United States)

    Wagar, Elizabeth A; Tamashiro, Lorraine; Yasin, Bushra; Hilborne, Lee; Bruckner, David A

    2006-11-01

    Patient safety is an increasingly visible and important mission for clinical laboratories. Attention to improving processes related to patient identification and specimen labeling is being paid by accreditation and regulatory organizations because errors in these areas that jeopardize patient safety are common and avoidable through improvement in the total testing process. To assess patient identification and specimen labeling improvement after multiple implementation projects using longitudinal statistical tools. Specimen errors were categorized by a multidisciplinary health care team. Patient identification errors were grouped into 3 categories: (1) specimen/requisition mismatch, (2) unlabeled specimens, and (3) mislabeled specimens. Specimens with these types of identification errors were compared preimplementation and postimplementation for 3 patient safety projects: (1) reorganization of phlebotomy (4 months); (2) introduction of an electronic event reporting system (10 months); and (3) activation of an automated processing system (14 months) for a 24-month period, using trend analysis and Student t test statistics. Of 16,632 total specimen errors, mislabeled specimens, requisition mismatches, and unlabeled specimens represented 1.0%, 6.3%, and 4.6% of errors, respectively. Student t test showed a significant decrease in the most serious error, mislabeled specimens (P patient safety projects. Trend analysis demonstrated decreases in all 3 error types for 26 months. Applying performance-improvement strategies that focus longitudinally on specimen labeling errors can significantly reduce errors, therefore improving patient safety. This is an important area in which laboratory professionals, working in interdisciplinary teams, can improve safety and outcomes of care.

  19. Influence of specimen size on the creep of rock salt

    International Nuclear Information System (INIS)

    Senseny, P.E.

    1982-01-01

    Triaxial compression creep data for Avery Island dome salt are analyzed to determine the influence of specimen size on creep deformation. Laboratory experiments were performed on 50- and 100-mm-diameter specimens in the temperature range from 25 to 200 0 C and the axial stress difference range from 2.5 to 31.0 MPa. The strain-vs-time data from each test are divided into transient and steady-state components. Results of statistical analysis of these data show that transient creep of the small specimens is a stronger function of stress, temperature, and time than is transient creep of the larger specimens. Analysis of the steady-state data show no size effect, however. 14 references, 7 figures, 3 tables

  20. Laparoscopic right-sided colonic resection with transluminal colonoscopic specimen extraction

    Science.gov (United States)

    Kayaalp, Cuneyt; Kutluturk, Koray; Yagci, Mehmet Ali; Ates, Mustafa

    2015-01-01

    AIM: To study the transcolonic extraction of the proximally resected colonic specimens by colonoscopic assistance at laparoscopic colonic surgery. METHODS: The diagnoses of our patients were Crohn’s disease, carcinoid of appendix and adenocarcinoma of cecum. We preferred laparoscopic total mesocolic resections. Colon and terminal ileum were divided with endoscopic staplers. A colonoscope was placed per anal and moved proximally in the colon till to reach the colonic closed end under the laparoscopic guidance. The stump of the colon was opened with laparoscopic scissors. A snare of colonoscope was released and the intraperitoneal complete free colonic specimen was grasped. Specimen was moved in to the colon with the help of the laparoscopic graspers and pulled gently through the large bowel and extracted through the anus. The open end of the colon was closed again and the ileal limb and the colon were anastomosed intracorporeally with a 60-mm laparoscopic stapler. The common enterotomy orifice was closed in two layers with a running intracorporeal suture. RESULTS: There were three patients with laparoscopic right-sided colonic resections and their specimens were intended to remove through the remnant colon by colonoscopy but the procedure failed in one patient (adenocarcinoma) due to a bulky mass and the specimen extraction was converted to transvaginal route. All the patients had prior abdominal surgeries and had related adhesions. The operating times were 210, 300 and 500 min. The lengths of the specimens were 13, 17 and 27 cm. In our cases, there were no superficial or deep surgical site infections or any other complications. The patients were discharged uneventfully within 4-5 d and they were asymptomatic after a mean 7.6 mo follow-up (ranged 4-12). As far as we know, there were only 12 cases reported yet on transcolonic extraction of the proximal colonic specimens by colonoscopic assistance after laparoscopic resections. With our cases, success rate of the

  1. Laser weld reconstitution of conventional Charpy and Miniaturized Notch Test (MNT) specimens

    International Nuclear Information System (INIS)

    Manahan, M.P.; Williams, J.; Martukanitz, R.P.

    1993-01-01

    As nuclear power plants approach end-of-license (EOL) and consideration is given to license renewal, there is an ever increasing need to expand the amount of data obtainable from the original surveillance specimens. A laser welding technique to reconstitute broken Charpy specimens is being developed to produce both conventional and miniaturized Charpy specimens. This paper reports on early laser welding development efforts and summarizes previous proof-of-principle experiments on a 1/16 scale miniaturized Charpy test. In order to benchmark the laser welding procedure, the laser-reconstituted specimen data have been compared with the original specimen data. In addition, the microstructure after welding has been examined to ensure that the material in the vicinity of the notch is essentially unchanged after the welding process. Data which characterize the thermal transient during welding are obtained by attaching thermocouples to the specimens. Other important considerations include perturbation of the stress field near the notch, dynamic stress waves, and contact of the weld region with the tup. Precise control of welding parameters has been demonstrated, heat-affected zones as small as 0.25 mm can be achieved, and sufficient penetration depth can be obtained to enable welding thick sections (1T or greater) to yield conventional Charpy specimens or fracture toughness specimens and thin sections (∼5 mm) to yield Miniaturized Notch Test (MNT) specimens

  2. Fracture toughness of Charpy-size compound specimens and its application in engineering

    International Nuclear Information System (INIS)

    Zhang, X.P.; Shi, Y.W.

    1994-01-01

    The use of a pre-cracked Charpy-size specimen with a side-groove to evaluate the fracture toughness of materials has been researched and considered. This method not only satisfies the demand for small-size specimens in surveillance tests of fracture toughness but also avoids using complicated physical methods to monitor the initial conditions of crack propagation. For most materials this method has solved the problem in which the small-size specimen did not satisfy the valid conditions of a fracture toughness measurement. In order to obtain more information from neutron-irradiated sample specimens and raise the reliability of fracture toughness surveillance tests, it has been considered more important to repeatedly exploit the broken Charpy-size specimen tested in the surveillance test, and to make it renewable. In this work, on the renewing design and utilization of Charpy-size specimens, nine data on fracture toughness can be obtained from one pre-cracked side-grooved Charpy-size specimen, while at present usually only one to three data on fracture toughness can be obtained from one Charpy-size specimen. Thus, it is found that the new method would improve the reliability of fracture toughness surveillance testing and evaluation. In addition, some factors that affect the optimum design of pre-cracked deep side-groove Charpy-size compound specimens have also been discussed. (author)

  3. Length of time domestic dogs (Canis familiaris) spend smelling urine of gonadectomised and intact conspecifics.

    Science.gov (United States)

    Riach, Anna C; Asquith, Rachel; Fallon, Melissa L D

    2017-09-01

    Domestic dogs (Canis familiaris) use urine to communicate among themselves, however, it is unknown whether the gonadectomy (neutering or spaying) of a dog affects this communication in anyway. Urine samples from 10 intact and 10 gonadectomised, unfamiliar dogs were presented to 12 tester dogs to sniff under controlled conditions in a pilot study. The amount of time the tester dogs spent sniffing each sample was recorded. Overall, tester dogs were recorded smelling the urine of gonadectomised individuals for a longer time. In addition to the type of urine sample, the result is likely to have been influenced by the sex and status (gonadectomised or intact) of the tester dogs. The observed increase in the length of time spent sniffing urine from gonadectomised individuals could be explained by the tester dogs experiencing more difficulty in gaining information from the urine or facing more confusion while analysing the urine compared to the intact urine they have evolved to smell. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Isolation and Properties of Intact Chromoplasts from Tomato Fruits

    OpenAIRE

    Norio, Iwatsuki; Ryuichi, Moriyama; Tadashi, Asahi; Laboratory of Biochemistry, Faculty of Agriculture, Nagoya University; Laboratory of Biochemistry, Faculty of Agriculture, Nagoya University; Laboratory of Biochemistry, Faculty of Agriculture, Nagoya University

    1984-01-01

    Intact chromoplasts were isolated from tomato fruits at different ripening stages by Percoll density gradient centrifugation. The isolated chromoplast fractions were contaminated very little by other organelles, although the fraction from fully ripened fruits contained some mitochondria and microbodies. As the transformation of chloroplasts to chromoplasts proceeded, the density of the plastids decreased from 1.096 to 1.075g・cm^ and the decrease was related to a decrease in chlorophyll and an...

  5. Conductive hearing loss with an intact tympanic membrane due to non-inflammatory causes.

    Science.gov (United States)

    Choi, Jin Hyuk; Lee, Min Young; Park, Ji Hye; Lee, Kyu-Yup; Lee, Sang Heun; Jang, Jeong Hun

    2016-04-01

    We analyzed audiologic and surgical findings in patients with conductive hearing loss (CHL) with an intact tympanic membrane (TM) that was of a non-inflammatory origin. We reviewed data from patients who underwent exploratory tympanotomy for CHL with intact TM from January 1995 to November 2012. Patients with diseases of non-inflammatory origin were enrolled (69 patients; 79 ears). Patients were categorized into two groups: non-trauma (50 ears) and trauma (29 ears). Demographic data, intraoperative findings, and audiologic results were obtained and analyzed. Overall, the second decade was the most common age of diagnosis in both the non-trauma and trauma groups. Operative findings showed that ossicular dislocation was more prevalent than ossicular fixation; all trauma group subjects had ossicular dislocation. Short columellization or partial ossicular replacement was the most frequently adopted surgical procedures in both groups. Overall, audiologically, air-conduction thresholds (ACs) and air-bone gaps were significantly improved over the short- and long-term period in both groups. However, the non-trauma group had significantly higher preoperative ACs than the trauma group, especially at low frequencies. This study provides clinicians with useful information regarding the clinical characteristics of CHL with intact TM of non-inflammatory origin. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Increasing the efficiency of digitization workflows for herbarium specimens

    Directory of Open Access Journals (Sweden)

    Melissa Tulig

    2012-07-01

    Full Text Available The New York Botanical Garden Herbarium has been databasing and imaging its estimated 7.3 million plant specimens for the past 17 years. Due to the size of the collection, we have been selectively digitizing fundable subsets of specimens, making successive passes through the herbarium with each new grant. With this strategy, the average rate for databasing complete records has been 10 specimens per hour. With 1.3 million specimens databased, this effort has taken about 130,000 hours of staff time. At this rate, to complete the herbarium and digitize the remaining 6 million specimens, another 600,000 hours would be needed. Given the current biodiversity and economic crises, there is neither the time nor money to complete the collection at this rate.Through a combination of grants over the last few years, The New York Botanical Garden has been testing new protocols and tactics for increasing the rate of digitization through combinations of data collaboration, field book digitization, partial data entry and imaging, and optical character recognition (OCR of specimen images. With the launch of the National Science Foundation’s new Advancing Digitization of Biological Collections program, we hope to move forward with larger, more efficient digitization projects, capturing data from larger portions of the herbarium at a fraction of the cost and time.

  7. Catalogue of test specimens for non-destructive examination

    International Nuclear Information System (INIS)

    1985-05-01

    One of the key elements in assuring the integrity of reactor primary circuits is the availability of trustworthy non-destructive methods for detecting dangerous defects that may be present. Various approaches to making such examinations are being developed, including the use of ultrasonic and radiographic techniques. To demonstrate their capability and reliability, they must be tested on steel specimens reproducing the various types of faults which may arise in real primary circuit vessels and piping. Such specimens are costly to fabricate. It is therefore clearly desirable that existing specimens should be made accessible to as many organisations as possible for testing. This catalogue contains detailed Information on forty-odd deliberately flawed plates, blocks, vessels, etc. which have been produced in OECD countries, along with the name of a contact person to whom inquiries should be directed in each case

  8. Insight into the Supramolecular Architecture of Intact Diatom Biosilica from DNP-Supported Solid-State NMR Spectroscopy.

    Science.gov (United States)

    Jantschke, Anne; Koers, Eline; Mance, Deni; Weingarth, Markus; Brunner, Eike; Baldus, Marc

    2015-12-07

    Diatom biosilica is an inorganic/organic hybrid with interesting properties. The molecular architecture of the organic material at the atomic and nanometer scale has so far remained unknown, in particular for intact biosilica. A DNP-supported ssNMR approach assisted by microscopy, MS, and MD simulations was applied to study the structural organization of intact biosilica. For the first time, the secondary structure elements of tightly biosilica-associated native proteins in diatom biosilica were characterized in situ. Our data suggest that these proteins are rich in a limited set of amino acids and adopt a mixture of random-coil and β-strand conformations. Furthermore, biosilica-associated long-chain polyamines and carbohydrates were characterized, thereby leading to a model for the supramolecular organization of intact biosilica. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Guidebook for the fabrication of non-destructive testing (NDT) test specimens

    International Nuclear Information System (INIS)

    2001-01-01

    Non-destructive testing (NDT) test specimens constitute a very important part of training and certification of NDT personnel and are important for carrying out actual inspection and testing, and for achieving international harmonization of NDT practices. The IAEA organized an advisory group of experts to develop a Guidebook for Fabrication of NDT Test Specimens. The experts consulted the ISO/FDIS 9712-1999 requirements for training and certification of personnel and the suitability of various types of NDT test specimens that are needed to meet such requirements This guidebook presents a set of NDT test specimens, and the methodology and procedures for their fabrication

  10. Quantitative determination of alpha-quartz in airborne dust samples by x-ray diffraction

    International Nuclear Information System (INIS)

    Bayon, A.; Roca, M.

    1982-01-01

    The quantitative determination by X-ray diffractometry of alpha-quartz In airborne respirable dust samples on silver membrane filters is considered. A cobalt anode X-ray tube Is employed. NiO is used as Internal standard In order to compensate for both the variations of specimen absorption and the effect due to the nonuniformity of the incident X-ray beam and to the incomplete homogeneity on the filters of samples and standards. (Author) 17 refs

  11. Quantitative determination of alpha-quartz in airbone dust samples by X-ray diffraction

    International Nuclear Information System (INIS)

    Bayon, A.; Roca, M.

    1982-01-01

    The quantitative determination by X-ray diffractometry of alpha-quartz in airbone respirable dust samples on silver membrane filters is considered. A cobalt anode X-ray tube is employec. NiO is used as internal standard in order to compensate for both the variations of specimen absorption and the effect due to the nonuniformity of the incident X-ray beam and to the incomplete homogeneity on the filters of samples and standards. (auth.) [es

  12. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-01

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified. PMID:29337867

  13. Tensile and Creep Testing of Sanicro 25 Using Miniature Specimens.

    Science.gov (United States)

    Dymáček, Petr; Jarý, Milan; Dobeš, Ferdinand; Kloc, Luboš

    2018-01-16

    Tensile and creep properties of new austenitic steel Sanicro 25 at room temperature and operating temperature 700 °C were investigated by testing on miniature specimens. The results were correlated with testing on conventional specimens. Very good agreement of results was obtained, namely in yield and ultimate strength, as well as short-term creep properties. Although the creep rupture time was found to be systematically shorter and creep ductility lower in the miniature test, the minimum creep rates were comparable. The analysis of the fracture surfaces revealed similar ductile fracture morphology for both specimen geometries. One exception was found in a small area near the miniature specimen edge that was cut by electro discharge machining, where an influence of the steel fracture behavior at elevated temperature was identified.

  14. Alfredo Dugès' type specimens of amphibians and reptiles revisited.

    Science.gov (United States)

    Flores-Villela, Oscar; Ríos-Muñoz, César A; Magaña-Cota, Gloria E; Quezadas-Tapia, Néstor L

    2016-03-14

    The type specimens of amphibians and reptiles of the Museo de Historia Natural Alfredo Dugès, at the University of Guanajuato (MADUG) were reviewed following Smith & Necker's (1943) summary. Owing to this collection's eventful history and its historical importance as the oldest herpetological collection in Mexico, a review of its conservation status was needed. After many years, the collection has received proper recognition at the University of Guanajuato with a portion of the herpetological types considered "Precious Assets" of the university. We found 34 type specimens pertaining to 18 taxa; six are additional specimens to those previously reported; six herpetological types are missing, including the body of the type of Adelophis copei. All specimens are in good to reasonable condition except for the type of Rhinocheilus antonii, which has dried out completely. All specimens are illustrated to show their condition.

  15. Legionellosis and Lung Abscesses: Contribution of Legionella Quantitative Real-Time PCR to an Adapted Followup

    Directory of Open Access Journals (Sweden)

    G. Descours

    2013-01-01

    Full Text Available We report a case of severe Legionnaires' disease (LD complicated by a lung abscess in an immunocompetent patient who required ECMO therapy and thoracic surgery. The results of repeated Legionella quantitative real-time PCR performed on both sera and respiratory samples correlated with the LD severity and the poor clinical outcome. Moreover, the PCR allowed for the detection of Legionella DNA in the lung abscess specimen, which was negative when cultured for Legionella. This case report provides a logical basis for further investigations to examine whether the Legionella quantitative PCR could improve the assessment of LD severity and constitute a prognostic marker.

  16. Investigation of smooth specimen scc test procedures; variations in environment, specimen size, stressing frame, and stress state. [for high strength aluminum alloys

    Science.gov (United States)

    Lifka, B. W.; Sprowls, D. O.; Kelsey, R. A.

    1975-01-01

    The variables studied in the stress-corrosion cracking performance of high strength aluminum alloys were: (1) corrosiveness of the environment, (2) specimen size and stiffness of the stressing system, (3) interpretation of transgranular cracking, and (4) interaction of the state of stress and specimen orientation in a product with an anisotropic grain structure. It was shown that the probability of failure and time to fracture for a specimen loaded in direct tension are influenced by corrosion pattern, the stressing assembly stiffness, and the notch tensile strength of the alloy. Results demonstrate that the combination of a normal tension stress and a shear stress acting on the plane of maximum susceptibility in a product with a highly directional grain cause the greatest tendency for stress-corrosion cracking.

  17. Prototypic and Arkypallidal Neurons in the Dopamine-Intact External Globus Pallidus

    Science.gov (United States)

    Abdi, Azzedine; Mallet, Nicolas; Mohamed, Foad Y.; Sharott, Andrew; Dodson, Paul D.; Nakamura, Kouichi C.; Suri, Sana; Avery, Sophie V.; Larvin, Joseph T.; Garas, Farid N.; Garas, Shady N.; Vinciati, Federica; Morin, Stéphanie; Bezard, Erwan

    2015-01-01

    Studies in dopamine-depleted rats indicate that the external globus pallidus (GPe) contains two main types of GABAergic projection cell; so-called “prototypic” and “arkypallidal” neurons. Here, we used correlative anatomical and electrophysiological approaches in rats to determine whether and how this dichotomous organization applies to the dopamine-intact GPe. Prototypic neurons coexpressed the transcription factors Nkx2-1 and Lhx6, comprised approximately two-thirds of all GPe neurons, and were the major GPe cell type innervating the subthalamic nucleus (STN). In contrast, arkypallidal neurons expressed the transcription factor FoxP2, constituted just over one-fourth of GPe neurons, and innervated the striatum but not STN. In anesthetized dopamine-intact rats, molecularly identified prototypic neurons fired at relatively high rates and with high regularity, regardless of brain state (slow-wave activity or spontaneous activation). On average, arkypallidal neurons fired at lower rates and regularities than prototypic neurons, and the two cell types could be further distinguished by the temporal coupling of their firing to ongoing cortical oscillations. Complementing the activity differences observed in vivo, the autonomous firing of identified arkypallidal neurons in vitro was slower and more variable than that of prototypic neurons, which tallied with arkypallidal neurons displaying lower amplitudes of a “persistent” sodium current important for such pacemaking. Arkypallidal neurons also exhibited weaker driven and rebound firing compared with prototypic neurons. In conclusion, our data support the concept that a dichotomous functional organization, as actioned by arkypallidal and prototypic neurons with specialized molecular, structural, and physiological properties, is fundamental to the operations of the dopamine-intact GPe. PMID:25926446

  18. Anterolateral Ligament of the Knee Shows Variable Anatomy in Pediatric Specimens.

    Science.gov (United States)

    Shea, Kevin G; Milewski, Matthew D; Cannamela, Peter C; Ganley, Theodore J; Fabricant, Peter D; Terhune, Elizabeth B; Styhl, Alexandra C; Anderson, Allen F; Polousky, John D

    2017-06-01

    Anterior cruciate ligament (ACL) reconstruction failure rates are highest in youth athletes. The role of the anterolateral ligament in rotational knee stability is of increasing interest, and several centers are exploring combined ACL and anterolateral ligament reconstruction for these young patients. Literature on the anterolateral ligament of the knee is sparse in regard to the pediatric population. A single study on specimens younger than age 5 years demonstrated the presence of the anterolateral ligament in only one of eight specimens; therefore, much about the prevalence and anatomy of the anterolateral ligament in pediatric specimens remains unknown. We sought to (1) investigate the presence or absence of the anterolateral ligament in prepubescent anatomic specimens; (2) describe the anatomic relationship of the anterolateral ligament to the lateral collateral ligament; and (3) describe the anatomic relationship between the anterolateral ligament and the physis. Fourteen skeletally immature knee specimens (median age, 8 years; range, 7-11 years) were dissected (12 male, two female specimens). The posterolateral structures were identified in all specimens, including the lateral collateral ligament and popliteus tendon. The presence or absence of the anterolateral ligament was documented in each specimen, along with origin, insertion, and dimensions, when applicable. The relationship of the anterolateral ligament origin to the lateral collateral ligament origin was recorded. The anterolateral ligament was identified in nine of 14 specimens. The tibial attachment point was consistently located in the same region on the proximal tibia, between the fibular head and Gerdy's tubercle; however, the femoral origin of the anterolateral ligament showed considerable variation with respect to the lateral collateral ligament origin. The median femoral origin of the anterolateral ligament was 10 mm (first interquartile 6 mm, third interquartile 13) distal to the distal

  19. Ingested soluble CD14 from milk is transferred intact into the blood of newborn rats.

    Science.gov (United States)

    Ward, Tonya L; Spencer, William J; Davis, Laura D R; Harrold, Joann; Mack, David R; Altosaar, Illimar

    2014-02-01

    Milk acts as an edible immune system that is transferred from mother to newborn. Soluble Cluster of Differentiation 14 (sCD14) is a protein found in significant quantities in human milk (~8-29 µg/ml). At a 10-fold lower concentration in the blood (~3 µg/ml), the most notable role of sCD14 is to sequester lipopolysaccharides of Gram-negative bacteria from immune cells. To explore the pharmacodynamics of this milk protein and its biological fate, the biodistribution of radiolabeled sCD14 ((14)C, (125)I) was monitored in 10-d-old rat pups. Up to 3.4 ± 2.2% of the radiolabeled sCD14 administered was observed, intact, in the pup blood for up to 8 h post-ingestion. Additionally, 30.3 ± 13.0% of the radiolabeled sCD14 administered was observed degraded in the stomach at 8 h post-ingestion. A reservoir of intact, administered sCD14 (3.2 ± 0.3%), however, remained in the stomach at 8 h post-ingestion. Intact sCD14 was observed in the small intestine at 5.5 ± 1.6% of the dose fed at 8 h post-ingestion. The presence of intact sCD14 in the blood and the gastrointestinal tract of newborns post-ingestion has implications in the development of allergies, obesity, and other inflammation-related pathogeneses later in life.

  20. A method to detect transfected chloramphenicol acetyltransferase gene expression in intact animals

    International Nuclear Information System (INIS)

    Narayanan, R.; Jastreboff, M.M.; Chiu, Chang Fang; Ito, Etsuro; Bertino, J.R.

    1988-01-01

    A rapid procedure is described for assaying chloramphenicol acetyltransferase enzyme activity in intact animals following transfection of the RSV CAT plasmid into mouse bone marrow cells by electroporation. The reconstituted mice were injected with [ 14 C]chloramphenicol and ethyl acetate extracts of 24-h urine samples were analyzed by TLC autoradiography for the excretion of 14 C-labeled metabolites. CAT expression in vivo can be detected by the presence of acetylated 14 C-labeled metabolites in the urine within 1 week after bone marrow transplantation and, under the conditions described, these metabolites can be detected for at least 3 months. CAT expression in intact mice as monitored by the urine assay correlates with the CAT expression in the hematopoietic tissues assayed in vitro. This method offers a quick mode of screening for introduced CAT gene expression in vivo without sacrificing the mice

  1. A quantitative ELISA procedure for the measurement of membrane-bound platelet-associated IgG (PAIgG).

    Science.gov (United States)

    Lynch, D M; Lynch, J M; Howe, S E

    1985-03-01

    A quantitative ELISA assay for the measurement of in vivo bound platelet-associated IgG (PAIgG) using intact patient platelets is presented. The assay requires quantitation and standardization of the number of platelets bound to microtiter plate wells and an absorbance curve using quantitated IgG standards. Platelet-bound IgG was measured using an F(ab')2 peroxidase labeled anti-human IgG and o-phenylenediamine dihydrochloride (OPD) as the substrate. Using this assay, PAIgG for normal individuals was 2.8 +/- 1.6 fg/platelet (mean +/- 1 SD; n = 30). Increased levels were found in 28 of 30 patients with clinical autoimmune thrombocytopenia (ATP) with a range of 7.0-80 fg/platelet. Normal PAIgG levels were found in 26 of 30 patients with nonimmune thrombocytopenia. In the sample population studied, the PAIgG assay showed a sensitivity of 93%, specificity of 90%, a positive predictive value of 0.90, and a negative predictive value of 0.93. The procedure is highly reproducible (CV = 6.8%) and useful in evaluating patients with suspected immune mediated thrombocytopenia.

  2. 46 CFR 57.06-4 - Production testing specimen requirements.

    Science.gov (United States)

    2010-10-01

    ... WELDING AND BRAZING Production Tests § 57.06-4 Production testing specimen requirements. (a) For test... 46 Shipping 2 2010-10-01 2010-10-01 false Production testing specimen requirements. 57.06-4... to welding shall not throw the finished test plate out of line by an angle of over 5°. (c) Where the...

  3. Thermal Cycling of Uranium Dioxide - Tungsten Cermet Fuel Specimens

    Energy Technology Data Exchange (ETDEWEB)

    Gripshover, P.J.; Peterson, J.H.

    1969-12-08

    In phase I tungsten clad cermet fuel specimens were thermal cycled, to study the effects of fuel loading, fuel particle size, stablized fuel, duplex coatings, and fabrication techniques on dimensional stability during thermal cycling. In phase II the best combination of the factors studies in phase I were combined in one specimen for evaluation.

  4. Wildlife as a bioindicator for specimen banking. Final report; Wild als Indikator fuer die Umweltprobenbank. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Holm, J; Wester, D; Wolfsteller, B

    1990-07-01

    The present report summarizes the documentation of five years` work on establishing the standard operation procedures for roe deer (Capreolus Capreolus). The criteria for bioindication of roe deer are listed for the region of Braunschweig, Fallersleben and the Lappwald. The organs investigated are liver, kidney, kidney fat and brain. The organs were collected from shot animals with intact abdomen and are packed uncontaminated in teflon bags. The fresh samples are kept at +4 C and prepared in a laboratory after 24 hours. The organs are analysed for 20 organic and 15 anorganic compounds. 22 detectible contaminats from different collectives are evaluated by using a PC with a SPSS programm. The results show the liver as a good accumulating organ. The size of this organ as well as the regular distribution of the contaminants are further factors in favour of taking the liver. Significant variations of the contaminants can be observed in the months of May to August, while the contaminants stabilize in September to November. Animals <18 months should be selected from fairly narrow and uniform biotopes for specimen banking during the periods of autumn to winter or May. A pooling of the samples is not to be advised. (orig.)

  5. Beta Adrenergic Regulation of Intrapulmonary Arteriovenous Anastomoses in Intact Rat and Isolated Rat Lungs

    Directory of Open Access Journals (Sweden)

    Melissa L. Bates

    2017-04-01

    Full Text Available Intrapulmonary arteriovenous anastomoses (IPAVA allow large diameter particles of venous origin to bypass the pulmonary capillary bed and embolize the systemic arterial circulation. IPAVA have been routinely observed in healthy humans with exercise, hypoxia, and catecholamine infusion, but the mechanism by which they are recruited is not well-defined. We hypothesized that beta-adrenergic receptor stimulation recruits IPAVA and that receptor blockade would limit hypoxia-induced IPAVA recruitment. To test our hypothesis, we evaluated the transpulmonary passage of microspheres in intact rats and isolated rats lung infused with the beta-adrenergic receptor agonist isoproterenol. We also evaluated IPAVA recruitment in intact rats with hypoxia and the beta-adrenergic receptor blocker propranolol. We found that IPAVA are recruited in the intact rat by isoproterenol and their recruitment by hypoxia can be minimized by propranolol, suggesting a role for the adrenergic system in the recruitment of IPAVA by hypoxia. IPAVA recruitment is completely abolished by ventilation with 100% oxygen. Isoproterenol also recruits IPAVA in isolated rat lungs. The fact that isoproterenol can recruit IPAVA in isolated lungs, without increased pulmonary flow, suggests that elevated cardiac output is not required for IPAVA recruitment.

  6. Perineal hernia repair using an autologous tunica vaginalis communis in nine intact male dogs.

    Science.gov (United States)

    Pratummintra, Kittiya; Chuthatep, Suwicha; Banlunara, Wijit; Kalpravidh, Marissak

    2013-01-01

    Perineal hernia in dogs is very problematic and mostly requires surgical reconstruction of the weak pelvic diaphragm. Tissue or synthetic grafts have been used for the correction after failure of the conventional herniorrhaphy. Aim of this clinical trial was to assess the possible use of the autologous tunica vaginalis communis as a free graft for perineal hernia repair in intact male dogs. Seven unilateral and 2 bilateral perineal hernias in nine intact male dogs free from testicular and scrotal neoplasms were included in this study. The median surgical time for unilateral herniorrhaphy was 75 min. The median follow-up time was 13 months. The success of the autografting, based on no recurrence and comfort of the animals during urination and defecation, was found in ten of 11 hernias; giving a success rate of 90.91%. One hernia (9.09%) recurred 10 days after surgery. Histopathological examination of the apposing area between the graft and the adjacent tissue, taken during the repair of the recurred case at day 20, revealed neovascularization and connective tissue ingrowth. In conclusion, the tunica vaginalis autograft can be used for perineal herniorrhaphy in intact male dogs.

  7. Transmission electron microscopy of bulk specimens over 10 µm in thickness

    Energy Technology Data Exchange (ETDEWEB)

    Sadamatsu, Sunao, E-mail: sadamatsu@mech.kagoshima-u.ac.jp [Department of Mechanical Engineering, Kagoshima University, Korimoto, Kagoshima 890-0065 (Japan); Tanaka, Masaki; Higashida, Kenji [Department of Materials Science and Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Matsumura, Syo [Department of Applied Quantum Physics and Nuclear Engineering, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan); Ultramicroscopy Research Center, Kyushu University, Nishi-ku, Fukuoka 819-0395 (Japan)

    2016-03-15

    We succeeded the observation of microstructures in bulk-sized specimens of over 10 µm in thickness by employing a technique that combines transmission electron microscopy (TEM) with energy-filtered imaging based on electron energy-loss spectroscopy (EELS). This method is unique in that it incorporates the inelastically scattered electrons into the imaging process. Using this technique, bright and sharp images of dislocations in crystalline silicon specimens as thick as 10 µm were obtained. A calibration curve to determine foil thickness of such a thick specimen was also derived. This method simply extends the observable thickness range in TEM. If combined with tilt series of observation over a significant range of angle, it will disclose three dimensional nanostructures in a µm-order block of a specimen, promoting our understanding of the controlling mechanisms behind various bulky material properties. - Highlights: • We developed a method which enables thick specimens to be observed using EF-TEM. • The effects of energy filter width and position on images were determined. • We suggested a method to determine the thickness of a thick film sample. • We achieved observation of microstructures in specimens with a thickness of 10 µm.

  8. Metabolism of inhaled ethane and pentane by the intact rat

    International Nuclear Information System (INIS)

    Daugherty, M.S.; Luddent, T.M.; Burk, R.F.

    1986-01-01

    Measurement of exhaled ethane or pentane is a noninvasive technique for studying in vivo lipid peroxidation. Many past studies have assumed that pentane and ethane are not metabolized. Radiolabeled ( 14 C) ethane and pentane were used to study the disposition of these compounds in intact rats. Rats were placed for 8 h in a closed plexiglass chamber fitted with a system for replenishing chamber atmospheric O 2 . Evolved CO 2 was trapped by recirculating chamber air through 3 N NaOH contained in a vessel external to the chamber. Radiolabeled ethane or pentane was injected into the chamber at the start of each experiment. The percent of 14 C-activity added to the chamber recovered in the CO 2 trap, urine, and chamber air at the end of the experiment (8 h) in the [ 14 C]-ethane (n=5) and [ 14 C]-pentane (n=4) studies are presented. Results indicate that both ethane and pentane are metabolized to CO 2 in the intact rat. Possible changes in ethane and pentane metabolism must be considered if the exhalation rates of these hydrocarbons are to be used as indices of in vivo lipid peroxidation

  9. Design Analysis of the Mixed Mode Bending Sandwich Specimen

    DEFF Research Database (Denmark)

    Quispitupa, Amilcar; Berggreen, Christian; Carlsson, Leif A.

    2010-01-01

    A design analysis of the mixed mode bending (MMB) sandwich specimen for face–core interface fracture characterization is presented. An analysis of the competing failure modes in the foam cored sandwich specimens is performed in order to achieve face–core debond fracture prior to other failure modes...... for the chosen geometries and mixed mode loading conditions....

  10. Single specimen fracture toughness determination procedure using instrumented impact test

    International Nuclear Information System (INIS)

    Rintamaa, R.

    1993-04-01

    In the study a new single specimen test method and testing facility for evaluating dynamic fracture toughness has been developed. The method is based on the application of a new pendulum type instrumented impact tester equipped with and optical crack mouth opening displacement (COD) extensometer. The fracture toughness measurement technique uses the Double Displacement Ratio (DDR) method, which is based on the assumption that the specimen is deformed as two rigid arms that rotate around an apparent centre of rotation. This apparent moves as the crack grows, and the ratio of COD versus specimen displacement changes. As a consequence the onset ductile crack initiation can be detected on the load-displacement curve. Thus, an energy-based fracture toughness can be calculated. In addition the testing apparatus can use specimens with the Double ligament size as compared with the standard Charpy specimen which makes the impact testing more appropriate from the fracture mechanics point of view. The novel features of the testing facility and the feasibility of the new DDR method has been verified by performing an extensive experimental and analytical study. (99 refs., 91 figs., 27 tabs.)

  11. Allergenicity, immunogenicity and dose-relationship of three intact allergen vaccines and four allergoid vaccines for subcutaneous grass pollen immunotherapy.

    Science.gov (United States)

    Henmar, H; Lund, G; Lund, L; Petersen, A; Würtzen, P A

    2008-09-01

    Different vaccines containing intact allergens or chemically modified allergoids as active ingredients are commercially available for specific immunotherapy. Allergoids are claimed to have decreased allergenicity without loss of immunogenicity and this is stated to allow administration of high allergoid doses. We compared the allergenicity and immunogenicity of four commercially available chemically modified grass pollen allergoid products with three commercially available intact grass pollen allergen vaccines. The allergenicity was investigated with immunoglobulin (Ig)E-inhibition and basophil activation assays. Human T cell proliferation and specific IgG-titres following mouse immunizations were used to address immunogenicity. Furthermore, intact allergen vaccines with different contents of active ingredients were selected to study the influence of the allergen dose. In general, a lower allergenicity for allergen vaccines was clearly linked to a reduced immunogenicity. Compared with the vaccine with the highest amount of intact allergen, the allergoids caused reduced basophil activation as well as diminished immunogenicity demonstrated by reduced T cell activation and/or reduced induction of murine grass-specific IgG antibodies. Interestingly, intact allergen vaccines with lower content of active ingredient exhibited similarly reduced allergenicity, while immunogenicity was still higher or equal to that of allergoids. The low allergenicity observed for some allergoids was inherently linked to a significantly lower immunogenic response questioning the rationale behind the chemical modification into allergoids. In addition, the linkage between allergenicity, immunogenicity and dose found for intact allergen vaccines and the immunogen as well as allergenic immune responses observed for allergoids suggest that the modified allergen vaccines do not contain high doses of immunologically active ingredients.

  12. Characterization of Cement Particles Found in Peri-implantitis-Affected Human Biopsy Specimens.

    Science.gov (United States)

    Burbano, Maria; Wilson, Thomas G; Valderrama, Pilar; Blansett, Jonathan; Wadhwani, Chandur P K; Choudhary, Pankaj K; Rodriguez, Lucas C; Rodrigues, Danieli C

    2015-01-01

    Peri-implantitis is a disease characterized by soft tissue inflammation and continued loss of supporting bone, which can result in implant failure. Peri-implantitis is a multifactorial disease, and one of its triggering factors may be the presence of excess cement in the soft tissues surrounding an implant. This descriptive study evaluated the composition of foreign particles from 36 human biopsy specimens with 19 specimens selected for analysis. The biopsy specimens were obtained from soft tissues affected by peri-implantitis around cement-retained implant crowns and compared with the elemental composition of commercial luting cement. Nineteen biopsy specimens were chosen for the comparison, and five test cements (TempBond, Telio, Premier Implant Cement, Intermediate Restorative Material, and Relyx) were analyzed using scanning electron microscopy equipped with energy dispersive x-ray spectroscopy. This enabled the identification of the chemical composition of foreign particles embedded in the tissue specimens and the composition of the five cements. Statistical analysis was conducted using classification trees to pair the particles present in each specimen with the known cements. The particles in each biopsy specimen could be associated with one of the commercial cements with a level of probability ranging between .79 and 1. TempBond particles were found in one biopsy specimen, Telio particles in seven, Premier Implant Cement particles in four, Relyx particles in four, and Intermediate Restorative Material particles in three. Particles found in human soft tissue biopsy specimens around implants affected by peri-implant disease were associated with five commercially available dental cements.

  13. Sem-observation of developing plant organs using deep-frozen specimens

    NARCIS (Netherlands)

    NN,

    1982-01-01

    The SEM-observation of plant material normally requires dehydrated, dry specimens coated with carbon or metal. Unfortunately, the standard drying methods (including the critical-point-drying-technique) often cause shrinking and deformation of the specimen surface; therefore, SEMstudies on plant

  14. Operative findings of conductive hearing loss with intact tympanic membrane and normal temporal bone computed tomography.

    Science.gov (United States)

    Kim, Se-Hyung; Cho, Yang-Sun; Kim, Hye Jeong; Kim, Hyung-Jin

    2014-06-01

    Despite recent technological advances in diagnostic methods including imaging technology, it is often difficult to establish a preoperative diagnosis of conductive hearing loss (CHL) in patients with an intact tympanic membrane (TM). Especially, in patients with a normal temporal bone computed tomography (TBCT), preoperative diagnosis is more difficult. We investigated middle ear disorders encountered in patients with CHL involving an intact TM and normal TBCT. We also analyzed the surgical results with special reference to the pathology. We reviewed the medical records of 365 patients with intact TM, who underwent exploratory tympanotomy for CHL. Fifty nine patients (67 ears, eight bilateral surgeries) had a normal preoperative TBCT findings reported by neuro-radiologists. Demographic data, otologic history, TM findings, preoperative imaging findings, intraoperative findings, and pre- and postoperative audiologic data were obtained and analyzed. Exploration was performed most frequently in the second and fifth decades. The most common postoperative diagnosis was stapedial fixation with non-progressive hearing loss. The most commonly performed hearing-restoring procedure was stapedotomy with piston wire prosthesis insertion. Various types of hearing-restoring procedures during exploration resulted in effective hearing improvement, especially with better outcome in the ossicular chain fixation group. In patients with CHL who have intact TM and normal TBCT, we should consider an exploratory tympanotomy for exact diagnosis and hearing improvement. Information of the common operative findings from this study may help in preoperative counseling.

  15. Histological evaluation of 400 cholecystectomy specimens

    Directory of Open Access Journals (Sweden)

    H Kumar

    2015-09-01

    Full Text Available Background: A majority of gallbladder specimens show changes associated with chronic cholecystitis; however few harbour a highly lethal carcinoma. This study was conducted to review the significant histopathological findings encountered in gallbladder specimens received in our laboratory.Materials and Methods: Four hundred cholecystectomy specimens were studied over a period of five years (May, 2002 to April, 2007 received at department of pathology, Kasturba Medical College, Mangalore, India. Results: Gallstones and associated diseases were more common in women in the 4th to 5th decade as compared to men with M: F ratio of 1:1.33. Maximum number of patients (28.25% being 41 to 50 years old. Histopathologically, the most common diagnosis was chronic cholecystitis (66.75%, followed by chronic active cholecystitis (20.25%, acute cholecystitis (6%, gangrenous cholecystitis (2.25%,xanthogranulomatous cholecystitis (0.50%, empyema (1%, mucocele (0.25%, choledochal cyst (0.25%, adenocarcinoma gallbladder (1.25% and  normal  gallbladders (1%.Conclusion: All lesions were found more frequently in women except chronic active cholecystitis. Gallstones were present in (80.25% cases, and significantly associated with various lesions (P value 0.009. Pigment stones were most common, followed by cholesterol stones and mixed stones. Adequate  sectioning  is  mandatory  in  all  cases  to  assess  epithelial changes arising from cholelithiasis and chronic cholecystitis as it has been known to progress to malignancy in some cases.

  16. Tensile tests and metallography of brazed AISI 316L specimens after irradiation

    International Nuclear Information System (INIS)

    Groot, P.; Franconi, E.

    1994-01-01

    Stainless steel type 316L tensile specimens were vacuum brazed with three kinds of alloys: BNi-5, BNi-6, and BNi-7. The specimens were irradiated up to 0.7 dpa at 353 K in the High Flux Reactor at JRC Petten, the Netherlands. Tensile tests were performed at a constant displacement rate of 10 -3 s -1 at room temperature in the ECN hot cell facility. BNi-5 brazed specimens showed ductile behaviour. Necking and fractures were localized in the plate material. BNi-6 and BNi-7 brazed specimens failed brittle in the brazed zone. This was preceded by uniform deformation of the plate material. Tensile test results of irradiated specimens showed higher stresses due to radiation hardening and a reduction of the elongation of the plate material compared to the reference. SEM examination of the irradiated BNi-6 and BNi-7 fracture surfaces showed nonmetallic phases. These phases were not found in the reference specimens. ((orig.))

  17. Role of specimen US for predicting resection margin status in breast conserving therapy.

    Science.gov (United States)

    Moschetta, M; Telegrafo, M; Introna, T; Coi, L; Rella, L; Ranieri, V; Cirili, A; Stabile Ianora, A A; Angelelli, G

    2015-01-01

    To assess the diagnostic accuracy of specimen ultrasound (US) for predicting resection margin status in women undergoing breast conserving therapy for US-detected cancer, having the histological findings as the reference standard. A total of 132 consecutive patients (age range, 34-87 years; mean, 51 years) underwent breast-conserving surgery for US-detected invasive breast cancer. All surgical specimens underwent US examination. The presence of lesion within the specimen and its distance from the specimen margins were assessed considering a threshold distance between the lesion and specimen margins of 10 mm. US findings were then compared with the pathological ones and specimen US. Sensitivity, specificity, diagnostic accuracy, positive (PPV) and negative predictive values (NPV) for predicting histological margin status were evaluated, having the histological findings as the reference standard. The histological examination detected invasive ductal carcinoma in 96/132 (73%) cases, invasive lobular carcinoma in 32/132 (24%), mucinous carcinoma in 4/132 (3%). The pathological margin analysis revealed 96/132 (73%) negative margins and 36 (27%) close/positive margins. US examination detected all 132 breast lesions within the surgical specimens. 110 (83%) negative margins and 22 (17%) positive margins were found on US. Sensitivity, specificity, diagnostic accuracy, PPV and NPV of 44%, 94%, 80%, 73% and 82%, respectively, were found for specimen US. Specimen US represents a time and cost saving imaging tool for evaluating the presence of US detected-breast lesion within surgical specimen and for predicting the histological margin status.

  18. Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens

    Science.gov (United States)

    Krause, David L.

    2000-01-01

    A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.

  19. Friction Compensation in the Upsetting of Cylindrical Test Specimens

    DEFF Research Database (Denmark)

    Christiansen, Peter; Martins, P. A. F.; Bay, Niels Oluf

    2016-01-01

    This manuscript presents a combined numerical andexperimental methodology for determining the stress-straincurve of metallic materials from the measurements of forceand displacement obtained in the axial compression of cylindrical test specimens with friction between the specimens and the platens....... The methodology is based on minimizing the errorbetween the average surface pressure obtained from the experimental measurements of the force and displacement and thatobtained from the slab method of analysis of metal plasticity.Three different friction models based on Coulomb friction, the constant friction...... model or combined friction models are utilized .Experimental results obtained from cylindrical and Rastegaev test specimens with different lubricants combined with the experimental determination of friction by means of ring compression tests allows compensating the effect of friction...

  20. JR-curves of wide plates and CT25 specimens

    International Nuclear Information System (INIS)

    Aurich, D.; Wobst, K.; Krafka, H.

    1987-01-01

    In connection with the problem of the applicability of the characteristic specimen date - i.e. the initiation and stable crack propagation under maximal loads, together with the elastic-plastic material behaviour - to that of actual components, spot-check type beside tests were conducted using wide-plate central crack, central notch (CCT, CNT) and double external crack (DECT) samples. The material in question was an StE 460 steel. A comparison between the determined values shows that the assessed pressure vessel behaviour differs extensively to the values derived from the CCT and CNT specimens. The corresponding results obtained from the CT25 and DECT specimens vary only slightly in the region of interest and correspond to real vessel values. (orig./DG) [de

  1. Extraction of ultrashort DNA molecules from herbarium specimens.

    Science.gov (United States)

    Gutaker, Rafal M; Reiter, Ella; Furtwängler, Anja; Schuenemann, Verena J; Burbano, Hernán A

    2017-02-01

    DNA extracted from herbarium specimens is highly fragmented; therefore, it is crucial to use extraction protocols that retrieve short DNA molecules. Improvements in extraction and DNA library preparation protocols for animal remains have allowed efficient retrieval of molecules shorter than 50 bp. Here, we applied these improvements to DNA extraction protocols for herbarium specimens and evaluated extraction performance by shotgun sequencing, which allows an accurate estimation of the distribution of DNA fragment lengths. Extraction with N-phenacylthiazolium bromide (PTB) buffer decreased median fragment length by 35% when compared with cetyl-trimethyl ammonium bromide (CTAB); modifying the binding conditions of DNA to silica allowed for an additional decrease of 10%. We did not observe a further decrease in length for single-stranded DNA (ssDNA) versus double-stranded DNA (dsDNA) library preparation methods. Our protocol enables the retrieval of ultrashort molecules from herbarium specimens, which will help to unlock the genetic information stored in herbaria.

  2. Quantitative Acoustic Emission Fatigue Crack Characterization in Structural Steel and Weld

    Directory of Open Access Journals (Sweden)

    Adutwum Marfo

    2013-01-01

    Full Text Available The fatigue crack growth characteristics of structural steel and weld connections are analyzed using quantitative acoustic emission (AE technique. This was experimentally investigated by three-point bending testing of specimens under low cycle constant amplitude loading using the wavelet packet analysis. The crack growth sequence, that is, initiation, crack propagation, and fracture, is extracted from their corresponding frequency feature bands, respectively. The results obtained proved to be superior to qualitative AE analysis and the traditional linear elastic fracture mechanics for fatigue crack characterization in structural steel and welds.

  3. Development of European creep crack growth testing code of practice for industrial specimens

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, B.; Nikbin, K. [Imperial College, London (United Kingdom); Petrovski, B. [Technische Univ. Darmstadt (DE). Inst. fuer Werkstoffkunde (IFW)

    2004-07-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elasticcreep, elastic compliance measurements.

  4. Development of European creep crack growth testing code of practice for industrial specimens

    International Nuclear Information System (INIS)

    Dogan, B.; Nikbin, K.; Petrovski, B.

    2004-01-01

    The integrity and residual life assessment of high temperature components require defects, detected or assumed to exist, through minimum allowable limits of detectable flaws using nondestructive testing methods. It relies on information obtained from the material's mechanical, uniaxial creep, creep crack initiation and growth properties. The information derived from experiments needs to be validated and harmonised following a Code of Practice that data variability between different institutions can be reduced to a minimum. The present paper reports on a Code of Practice (CoP) being prepared within the framework of the partially European Commission funded project CRETE. The novel aspect of the presented CoP is the inclusion of component relevant industrial specimen geometries. It covers testing and analysis of Creep Crack growth (CCG) in metallic materials at elevated temperature using six different cracked geometries that have been validated in. It aims to give advice on testing, measurements and analysis of creep crack growth data for a range of creep brittle to creep ductile materials using component service relevant specimen geometries and sizes. The CoP may be used for material selection criteria and inspection requirements for damage tolerant applications. In quantitative terms, these types of tests can be used to assess the individual and combined effects of metallurgical, fabrication, operating temperature, and loading conditions on creep crack growth life. Further issues will be addressed including material properties, damage and crack growth related constraint effect, stress relaxation and stress-strain fields, residual stresses, partitioning displacement, analysis of elastic creep, elastic compliance measurements

  5. Development of reconstitution method for surveillance specimens using surface activated joining

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Terumi; Kaihara, Shoichiro; Yoshida, Kazuo; Sato, Akira [Ishikawajima-Harima Heavy Industries Co. Ltd., Tokyo (Japan); Onizawa, Kunio; Nishiyama, Yutaka; Fukaya, Kiyoshi; Suzuki, Masahide

    1996-03-01

    Evaluation of embrittlement of reactor vessel steel due to irradiation requires surveillance tests. However, many surveillance specimens are necessary for nuclear plants life extension. Therefore, a specimen reconstitution technique has become important to provide the many specimens for continued surveillance. A surface activated joining (SAJ) method has been developed to join various materials together at low temperatures with little deformation, and is useful to bond irradiated specimens. To assess the validity of this method, Charpy impact tests were carried out, and the characteristics caused by heating during joining were measured. The test results showed the Charpy impact values were almost the same as base materials, and surface activated joining reduced heat affected zone to less than 2 mm. (author).

  6. 10 CFR 26.159 - Assuring specimen security, chain of custody, and preservation.

    Science.gov (United States)

    2010-01-01

    ... other entity has reason to question the integrity and identity of the specimens, the specimens may not... identification numbers on the custody-and-control form; (iii) A specimen bottle seal is broken or shows evidence... of the shipping containers are inaccessible without breaking a tamper-evident seal. (g) Couriers...

  7. Method and Apparatus for Measuring Thermal Conductivity of Small, Highly Insulating Specimens

    Science.gov (United States)

    Miller, Robert A (Inventor); Kuczmarski, Maria A (Inventor)

    2013-01-01

    A method and apparatus for the measurement of thermal conductivity combines the following capabilities: 1) measurements of very small specimens; 2) measurements of specimens with thermal conductivity on the same order of that as air; and, 3) the ability to use air as a reference material. Care is taken to ensure that the heat flow through the test specimen is essentially one-dimensional. No attempt is made to use heated guards to minimize the flow of heat from the hot plate to the surroundings. Results indicate that since large correction factors must be applied to account for guard imperfections when specimen dimensions are small, simply measuring and correcting for heat from the heater disc that does not flow into the specimen is preferable.

  8. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2011-10-15

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function {Phi}(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  9. Monte Carlo simulation of the electron and X-ray depth distribution for quantitative electron probe microanalysis of PWR spent fuels

    International Nuclear Information System (INIS)

    Kwon, Hyoung Mun; Lee, Hyung Kwon; Son, Young Zoon; Chun, Yong Bum

    2011-01-01

    Electron probe microanalysis requires several corrections to quantify an element of a specimen. The X-rays produced by the primary beam are created at some depth in the specimen. This distribution is usually represented as the function Φ(pz), and it is possible to calculate the correction factors for atomic number and absorption effects. The electron and X-ray depth distributions for a quantitative electron probe micro analysis were simulated by the CASINO Monte Carlo program to quantify some elements of the PWR spent fuel with 50 GWd/tU of burnup and 2 years of cooling time

  10. Gleason Score Correlation Between Prostate Biopsy and Radical Prostatectomy Specimens

    Directory of Open Access Journals (Sweden)

    Erdem Öztürk

    2018-04-01

    Full Text Available Objective: Prostate cancer is the most common malignancy in men and the second cause of cancer-related mortality. Prostate biopsy and the Gleason score guide treatment decisions in prostate cancer. Several studies have investigated the correlation between biopsy scores and radical prostatectomy specimen scores. We also evaluated the correlation of Gleason scores of these specimens in our patient series. Materials and Methods: We retrospectively reviewed the data of 468 men who were diagnosed with prostate cancer and underwent radical prostatectomy between 2008 and 2017. Patients’ age, prostate-specific antigen levels at diagnosis, and prostate biopsy and radical prostatectomy specimen Gleason scores were recorded. Upgrading and downgrading were defined as increase or decrease of Gleason score of radical prostate specimen compared to Gleason score of prostate biopsy. Results: A total of 442 men diagnosed with prostate cancer were included in the study. The mean age of the patients was 62.62±6.26 years (44-84 years and mean prostate specific antigen level was 9.01±6.84 ng/mL (1.09-49 ng/mL. Prostate biopsy Gleason score was 7 in 27 (6.1% men. Radical prostatectomy specimen Gleason score was 7 in 62 (14% men. Gleason correlation was highest in the 240 patients (71.6% with score <7 and was lowest in the 31 (38.75% patients with score =7. Conclusion: This study demonstrated that the discordance rate between Gleason scores of prostate biopsy and radical prostatectomy specimens was 35.7%.

  11. Human skin penetration of silver nanoparticles through intact and damaged skin

    International Nuclear Information System (INIS)

    Larese, Francesca Filon; D'Agostin, Flavia; Crosera, Matteo; Adami, Gianpiero; Renzi, Nadia; Bovenzi, Massimo; Maina, Giovanni

    2009-01-01

    There is a growing interest on nanoparticle safety for topical use. The benefits of nanoparticles have been shown in several scientific fields, but little is known about their potential to penetrate the skin. This study aims at evaluating in vitro skin penetration of silver nanoparticles. Experiments were performed using the Franz diffusion cell method with intact and damaged human skin. Physiological solution was used as receiving phase and 70 μg/cm 2 of silver nanoparticles coated with polyvinylpirrolidone dispersed in synthetic sweat were applied as donor phase to the outer surface of the skin for 24 h. The receptor fluid measurements were performed by electro thermal atomic absorption spectroscopy (ETAAS). Human skin penetration was also determined by using transmission electron microscope (TEM) to verify the location of silver nanoparticles in exposed membranes. Median silver concentrations of 0.46 ng cm -2 (range -2 (range 0.43-11.6) were found in the receiving solutions of cells where the nanoparticles solution was applied on intact skin (eight cells) and on damaged skin (eight cells), respectively. Twenty-four hours silver flux permeation in damaged skin was 0.62 ± 0.2 ng cm -2 with a lag time <1 h. Our experimental data showed that silver nanoparticles absorption through intact and damaged skin was very low but detectable, and that in case of damaged skin it was possible an increasing permeation of silver applied as nanoparticles. Moreover, silver nanoparticles could be detected in the stratum corneum and the outermost surface of the epidermis by electron microscopy. We demonstrated for the first time that silver applied as nanoparticles coated with polyvinylpirrolidone is able to permeate the damaged skin in an in vitro diffusion cell system

  12. Spatially Rearranged Object Parts Can Facilitate Perception of Intact Whole Objects

    Directory of Open Access Journals (Sweden)

    Laura eCacciamani

    2014-05-01

    Full Text Available The familiarity of an object depends on the spatial arrangement of its parts; when the parts are spatially rearranged, they form a novel, unrecognizable configuration. Yet the same collection of parts comprises both the familiar and novel configuration. Is it possible that the collection of familiar parts activates a representation of the intact familiar configuration even when they are spatially rearranged? We presented novel configurations as primes before test displays that assayed effects on figure-ground perception from memories of intact familiar objects. In our test displays, two equal-area regions shared a central border; one region depicted a portion of a familiar object. Previous research with such displays has shown that participants are more likely to perceive the region depicting a familiar object as the figure and the abutting region as its ground when the familiar object is depicted in its upright orientation rather than upside down. The novel primes comprised either the same or a different collection of parts as the familiar object in the test display (part-rearranged and control primes, respectively. We found that participants were more likely to perceive the familiar region as figure in upright vs. inverted displays following part-rearranged primes but not control primes. Thus, priming with a novel configuration comprising the same familiar parts as the upcoming figure-ground display facilitated orientation-dependent effects of object memories on figure assignment. Similar results were obtained when the spatially rearranged collection of parts was suggested on the groundside of the prime’s border, suggesting that familiar parts in novel configurations access the representation of their corresponding intact whole object before figure assignment. These data demonstrate that familiar parts access memories of familiar objects even when they are arranged in a novel configuration.

  13. Spatially rearranged object parts can facilitate perception of intact whole objects.

    Science.gov (United States)

    Cacciamani, Laura; Ayars, Alisabeth A; Peterson, Mary A

    2014-01-01

    The familiarity of an object depends on the spatial arrangement of its parts; when the parts are spatially rearranged, they form a novel, unrecognizable configuration. Yet the same collection of parts comprises both the familiar and novel configuration. Is it possible that the collection of familiar parts activates a representation of the intact familiar configuration even when they are spatially rearranged? We presented novel configurations as primes before test displays that assayed effects on figure-ground perception from memories of intact familiar objects. In our test displays, two equal-area regions shared a central border; one region depicted a portion of a familiar object. Previous research with such displays has shown that participants are more likely to perceive the region depicting a familiar object as the figure and the abutting region as its ground when the familiar object is depicted in its upright orientation rather than upside down. The novel primes comprised either the same or a different collection of parts as the familiar object in the test display (part-rearranged and control primes, respectively). We found that participants were more likely to perceive the familiar region as figure in upright vs. inverted displays following part-rearranged primes but not control primes. Thus, priming with a novel configuration comprising the same familiar parts as the upcoming figure-ground display facilitated orientation-dependent effects of object memories on figure assignment. Similar results were obtained when the spatially rearranged collection of parts was suggested on the groundside of the prime's border, suggesting that familiar parts in novel configurations access the representation of their corresponding intact whole object before figure assignment. These data demonstrate that familiar parts access memories of familiar objects even when they are arranged in a novel configuration.

  14. Comparison of measurement results between cervical pedicle specimens and CT images

    International Nuclear Information System (INIS)

    Zhang Guangjian; Li Hua; Liu Haiyan; Gao Zhenping

    2011-01-01

    Objective: To compare the difference between the measurement results of the cervical pedicle specimens and CT image, and provide the basis for clinical cervical screw internal fixation operation. Methods: Twenty-seven Chinese adult cadaver cervical specimens including C3 to C7 vertebrae were measured by a digital calipers and CT image, containing pedicle height (PH, PH'), pedicle width(PW, PW'), total pedicle length (TL, TL') and two pedicle lengths(PL1, PL2; PL1', PL2'). The results of specimens and CT image were compared. Results: Different cervical vertebra in the same side of specimens or CT images, PW (PW'): C3, C4< C5, C6 (P<0.05), C5, C6< C7 (P<0.01); PH (PH'): there were no significant differences; TL, PL1, PL2 (TL', PL1', PL2'): there were no marked differences. In the same cervical vertebra of the specimens or CT images, PW (PW')< PH (PH') (P<0.01), PL1 (PL1') < PL2 (PL2') (P<0.01). Conclusion: The results of measurement by CT images are not markedly different from that of specimens. CT image measurement is available before cervical screw internal fixation operation. (authors)

  15. Spectrophotometric Evaluation of the Pulpal Peroxide Levels in Intact and Restored Teeth - An Invitro Study.

    Science.gov (United States)

    Patri, Gaurav; Acharya, Gourismita; Agrawal, Pratik; Panda, Vijeta

    2016-08-01

    Hydrogen peroxide (30%) is a commonly used "in office" bleaching agent. Deleterious effects of hydrogen peroxide on the pulp have been observed. The present study was conducted with the aim to evaluate the penetration of 30% hydrogen peroxide into the pulp chamber through intact teeth and through the surface of teeth, restored with either hybrid composite or Resin Modified Glass Ionomer Cement (RMGIC). Sixty extracted human maxillary central incisors were selected and divided into six groups. Two groups were restored with hybrid composite resin and two with RMGIC, while two groups were left intact. The teeth with acetate buffer solution in their pulp cavity were then immersed in either 30% hydrogen peroxide or distilled water depending upon the group, for 60 minutes at 37°C. Then horseradish peroxidase and leucocrystal violet were added to the acetate buffer solution present in the pulp chamber after it was transferred to a test tube and the optical density of the resultant blue solution obtained was measured spectrophotometrically. The data obtained were analyzed using one way ANOVA and Student's t-test. The data obtained established that hydrogen peroxide penetrated into the pulp from the bleaching agent used. Hydrogen peroxide (30%) showed the highest pulpal peroxide level in teeth restored with RMGIC followed by teeth restored with hybrid composite resin and the least amount of penetration was observed in intact teeth. The amount of peroxide penetration into the tooth is more through restored tooth than intact tooth and is also dependant on the type of restorative materials used.

  16. The relationships between self-transcendence and spiritual well-being in cognitively intact nursing home patients.

    Science.gov (United States)

    Haugan, Gørill; Rannestad, Toril; Hammervold, Randi; Garåsen, Helge; Espnes, Geir A

    2014-03-01

    Self-transcendence is considered a developmental process of personal maturity and a vital resource of well-being in later adulthood. Measurement of the associations between self-transcendence and spiritual well-being in cognitively intact nursing home patients has not been previously published. The aim of this study was to identify the relationships between self-transcendence and spiritual well-being in cognitively intact nursing home patients. A cross-sectional design using the self-transcendence scale and the FACIT-Sp spiritual well-being questionnaire was adopted. A sample of 202 cognitively intact nursing home patients in mid-Norway was selected to respond to the questionnaires in 2008 and 2009. Statistical analyses were conducted using lisrel 8.8 (Scientific Software International, Chicago, IL, USA) and structural equation modelling. A hypothesised structural equation model comprising a two-factor construct of self-transcendence and a three-factor construct of spiritual well-being demonstrated significant direct relationships between self-transcendence and spiritual well-being and total effects of self-transcendence on spiritual well-being. Facilitating patients' self-transcendence, both interpersonally and intrapersonally, might increase spiritual well-being among cognitively intact nursing home patients, which is seen to be of great importance to nursing home patients' overall satisfaction and satisfaction with staff. The two-factor construct of self-transcendence and the three-factor construct of FACIT-Sp allow a more complex examination of the associations between the constructs and prove more specific guidelines for nursing interventions promoting well-being in nursing home patients. © 2013 Blackwell Publishing Ltd.

  17. Quantitative in-situ TEM nanotensile testing of single crystal Ni facilitated by a new sample preparation approach.

    Science.gov (United States)

    Samaeeaghmiyoni, Vahid; Idrissi, Hosni; Groten, Jonas; Schwaiger, Ruth; Schryvers, Dominique

    2017-03-01

    Twin-jet electro-polishing and Focused Ion Beam (FIB) were combined to produce small size Nickel single crystal specimens for quantitative in-situ nanotensile experiments in the transmission electron microscope. The combination of these techniques allows producing samples with nearly defect-free zones in the centre in contrast to conventional FIB-prepared samples. Since TEM investigations can be performed on the electro-polished samples prior to in-situ TEM straining, specimens with desired crystallographic orientation and initial microstructure can be prepared. The present results reveal a dislocation nucleation-controlled plasticity, in which small loops induced by FIB near the edges of the samples play a central role. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Detection and Differentiation of Leishmania spp. in Clinical Specimens by Use of a SYBR Green-Based Real-Time PCR Assay.

    Science.gov (United States)

    de Almeida, Marcos E; Koru, Ozgur; Steurer, Francis; Herwaldt, Barbara L; da Silva, Alexandre J

    2017-01-01

    Leishmaniasis in humans is caused by Leishmania spp. in the subgenera Leishmania and Viannia Species identification often has clinical relevance. Until recently, our laboratory relied on conventional PCR amplification of the internal transcribed spacer 2 (ITS2) region (ITS2-PCR) followed by sequencing analysis of the PCR product to differentiate Leishmania spp. Here we describe a novel real-time quantitative PCR (qPCR) approach based on the SYBR green technology (LSG-qPCR), which uses genus-specific primers that target the ITS1 region and amplify DNA from at least 10 Leishmania spp., followed by analysis of the melting temperature (T m ) of the amplicons on qPCR platforms (the Mx3000P qPCR system [Stratagene-Agilent] and the 7500 real-time PCR system [ABI Life Technologies]). We initially evaluated the assay by testing reference Leishmania isolates and comparing the results with those from the conventional ITS2-PCR approach. Then we compared the results from the real-time and conventional molecular approaches for clinical specimens from 1,051 patients submitted to the reference laboratory of the Centers for Disease Control and Prevention for Leishmania diagnostic testing. Specimens from 477 patients tested positive for Leishmania spp. with the LSG-qPCR assay, specimens from 465 of these 477 patients also tested positive with the conventional ITS2-PCR approach, and specimens from 10 of these 465 patients had positive results because of retesting prompted by LSG-qPCR positivity. On the basis of the T m values of the LSG-qPCR amplicons from reference and clinical specimens, we were able to differentiate four groups of Leishmania parasites: the Viannia subgenus in aggregate; the Leishmania (Leishmania) donovani complex in aggregate; the species L (L) tropica; and the species L (L) mexicana, L (L) amazonensis, L (L) major, and L (L) aethiopica in aggregate. Copyright © 2016 American Society for Microbiology.

  19. Use of precracked Charpy and smaller specimens to establish the master curve

    International Nuclear Information System (INIS)

    Sokolov, M.A.; McCabe, D.E.; Nanstad, R.K.; Davidov, Y.A.

    1997-01-01

    The current provisions used in the U.S. Code of Federal Regulations for the determination of the fracture toughness of reactor pressure vessel steels employs an assumption that there is a direct correlation between K Ic lower-bound toughness and the Charpy V-notch transition curve. Such correlations are subject to scatter from both approaches which weakens the reliability of fracture mechanics-based analyses. In this study, precracked Charpy and smaller size specimens are used in three-point static bend testing to develop fracture mechanics based K k values. The testing is performed under carefully controlled conditions such that the values can be used to predict the fracture toughness performance of large specimens. The concept of a universal transition curve (master curve) is applied. Data scatter that is characteristic of commercial grade steels and their weldments is handled by Weibull statistical modeling. The master curve is developed to describe the median K Jc fracture toughness for 1T size compact specimens. Size effects are modeled using weakest-link theory and are studied for different specimen geometries. It is shown that precracked Charpy specimens when tested within their confined validity limits follow the weakest-link size-adjustment trend and predict the fracture toughness of larger specimens. Specimens of smaller than Charpy sizes (5 mm thick) exhibit some disparities in results relative to weakest-link size adjustment prediction suggesting that application of such adjustment to very small specimens may have some limitations

  20. The effect of specimen and flaw dimensions on fracture toughness

    International Nuclear Information System (INIS)

    Nevalainen, M.J.

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account

  1. Quantitative X-ray microtomography with synchrotron radiation

    Energy Technology Data Exchange (ETDEWEB)

    Donath, T. [GKSS-Forschungszentrum Geesthacht GmbH (Germany). Inst. fuer Materialforschung

    2007-07-01

    Synchrotron-radiation-based computed microtomography (SR{sub {mu}}CT) is an established method for the examination of volume structures. It allows to measure the x-ray attenuation coefficient of a specimen three-dimensionally with a spatial resolution of about one micrometer. In contrast to conventional x-ray sources (x-ray tubes), the unique properties of synchrotron radiation enable quantitative measurements that do not suffer from beam-hardening artifacts. During this work the capabilities for quantitative SR{sub {mu}}CT measurements have been further improved by enhancements that were made to the SR{sub {mu}}CT apparatus and to the reconstruction chain. For high-resolution SR{sub {mu}}CT an x-ray camera consisting of luminescent screen (x-ray phosphor), lens system, and CCD camera was used. A significant suppression of blur that is caused by reflections inside the luminescent screen could be achieved by application of an absorbing optical coating to the screen surface. It is shown that blur and ring artifacts in the tomographic reconstructions are thereby drastically reduced. Furthermore, a robust and objective method for the determination of the center of rotation in projection data (sinograms) is presented that achieves sub-pixel precision. By implementation of this method into the reconstruction chain, complete automation of the reconstruction process has been achieved. Examples of quantitative SR{sub {mu}}CT studies conducted at the Hamburger Synchrotronstrahlungslabor HASYLAB at the Deutsches Elektronen-Synchrotron DESY are presented and used for the demonstration of the achieved enhancements. (orig.)

  2. Quantitative X-ray microtomography with synchrotron radiation

    International Nuclear Information System (INIS)

    Donath, T.

    2007-01-01

    Synchrotron-radiation-based computed microtomography (SR μ CT) is an established method for the examination of volume structures. It allows to measure the x-ray attenuation coefficient of a specimen three-dimensionally with a spatial resolution of about one micrometer. In contrast to conventional x-ray sources (x-ray tubes), the unique properties of synchrotron radiation enable quantitative measurements that do not suffer from beam-hardening artifacts. During this work the capabilities for quantitative SR μ CT measurements have been further improved by enhancements that were made to the SR μ CT apparatus and to the reconstruction chain. For high-resolution SR μ CT an x-ray camera consisting of luminescent screen (x-ray phosphor), lens system, and CCD camera was used. A significant suppression of blur that is caused by reflections inside the luminescent screen could be achieved by application of an absorbing optical coating to the screen surface. It is shown that blur and ring artifacts in the tomographic reconstructions are thereby drastically reduced. Furthermore, a robust and objective method for the determination of the center of rotation in projection data (sinograms) is presented that achieves sub-pixel precision. By implementation of this method into the reconstruction chain, complete automation of the reconstruction process has been achieved. Examples of quantitative SR μ CT studies conducted at the Hamburger Synchrotronstrahlungslabor HASYLAB at the Deutsches Elektronen-Synchrotron DESY are presented and used for the demonstration of the achieved enhancements. (orig.)

  3. Thermo-mechanical Fatigue Failure of Thermal Barrier Coated Superalloy Specimen

    Science.gov (United States)

    Subramanian, Rajivgandhi; Mori, Yuzuru; Yamagishi, Satoshi; Okazaki, Masakazu

    2015-09-01

    Failure behavior of thermal barrier coated (TBC) Ni-based superalloy specimens were studied from the aspect of the effect of bond coat material behavior on low cycle fatigue (LCF) and thermo-mechanical fatigue (TMF) at various temperatures and under various loading conditions. Initially, monotonic tensile tests were carried out on a MCrAlY alloy bond coat material in the temperature range of 298 K to 1273 K (25 °C to 1000 °C). Special attention was paid to understand the ductile to brittle transition temperature (DBTT). Next, LCF and TMF tests were carried out on the thermal barrier coated Ni-based alloy IN738 specimen. After these tests, the specimens were sectioned to understand their failure mechanisms on the basis of DBTT of the bond coat material. Experimental results demonstrated that the LCF and TMF lives of the TBC specimen were closely related to the DBTT of the bond coat material, and also the TMF lives were different from those of LCF tests. It has also been observed that the crack density in the bond coat in the TBC specimen was significantly dependent on the test conditions. More importantly, not only the number of cracks but also the crack penetration probability into substrate were shown to be sensitive to the DBTT.

  4. Differential effects of androgens on coronary blood flow regulation and arteriolar diameter in intact and castrated swine

    Directory of Open Access Journals (Sweden)

    O’Connor Erin K

    2012-05-01

    Full Text Available Abstract Background Low endogenous testosterone levels have been shown to be a risk factor for the development of cardiovascular disease and cardiovascular benefits associated with testosterone replacement therapy are being advocated; however, the effects of endogenous testosterone levels on acute coronary vasomotor responses to androgen administration are not clear. The objective of this study was to compare the effects of acute androgen administration on in vivo coronary conductance and in vitro coronary microvascular diameter in intact and castrated male swine. Methods Pigs received intracoronary infusions of physiologic levels (1–100 nM of testosterone, the metabolite 5α-dihydrotestosterone, and the epimer epitestosterone while left anterior descending coronary blood flow and mean arterial pressure were continuously monitored. Following sacrifice, coronary arterioles were isolated, cannulated, and exposed to physiologic concentrations (1–100 nM of testosterone, 5α-dihydrotestosterone, and epitestosterone. To evaluate effects of the androgen receptor on acute androgen dilation responses, real-time PCR and immunohistochemistry for androgen receptor were performed on conduit and resistance coronary vessels. Results In vivo, testosterone and 5α-dihydrotestosterone produced greater increases in coronary conductance in the intact compared to the castrated males. In vitro, percent maximal dilation of microvessels was similar between intact and castrated males for testosterone and 5α-dihydrotestosterone. In both studies epitestosterone produced significant increases in conductance and microvessel diameter from baseline in the intact males. Androgen receptor mRNA expression and immunohistochemical staining were similar in intact and castrated males. Conclusions Acute coronary vascular responses to exogenous androgen administration are increased by endogenous testosterone, an effect unrelated to changes in androgen receptor expression.

  5. An automated tensile machine for small specimens heavily neutron irradiated in FFTF/MOTA

    International Nuclear Information System (INIS)

    Kohyama, Akira; Sato, Shinji; Hamada, Kenichi

    1993-01-01

    The objective of this work is to develop a fully automated tensile machine for post-irradiation examination (PIE) of Fast Flux Test Facility (FFTF)/Materials Open Test Assembly (MOTA) irradiated miniature tension specimens. The anticipated merit of the automated tensile machine is to reduce damage to specimens during specimen handling for PIE and to reduce exposure to radioactive specimens. This machine is designed for testing at elevated temperatures, up to 873 K, in a vacuum or in an inert gas environment. Twelve specimen assemblies are placed in the vacuum chamber that can be tested successively in a fully automated manner. A unique automated tensile machine for the PIE of FFTF/MOTA irradiated specimens, the Monbusho Automated Tensile Machine (MATRON) consists of a test frame with controlling units and an automated specimen-loading apparatus. The qualification of the test frame has been completed, and the results have satisfied the machine specifications. The capabilities of producing creep and relaxation data have been demonstrated for Cu, Al, 316SS, and ferritic steels. The specimen holders for the three-point bending test and the small bulge test (small punch test; SP test) were also designed and produced

  6. Comparison of the quantitative analysis performance between pulsed voltage atom probe and pulsed laser atom probe

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, J., E-mail: takahashi.3ct.jun@jp.nssmc.com [Advanced Technology Research Laboratories, Nippon Steel & Sumitomo Metal Corporation, 20-1 Shintomi, Futtsu-city, Chiba 293-8511 (Japan); Kawakami, K. [Advanced Technology Research Laboratories, Nippon Steel & Sumitomo Metal Corporation, 20-1 Shintomi, Futtsu-city, Chiba 293-8511 (Japan); Raabe, D. [Max-Planck Institut für Eisenforschung GmbH, Department for Microstructure Physics and Alloy Design, Max-Planck-Str. 1, 40237 Düsseldorf (Germany)

    2017-04-15

    Highlights: • Quantitative analysis in Fe-Cu alloy was investigated in voltage and laser atom probe. • In voltage-mode, apparent Cu concentration exceeded actual concentration at 20–40 K. • In laser-mode, the concentration never exceeded the actual concentration even at 20 K. • Detection loss was prevented due to the rise in tip surface temperature in laser-mode. • Preferential evaporation of solute Cu was reduced in laser-mode. - Abstract: The difference in quantitative analysis performance between the voltage-mode and laser-mode of a local electrode atom probe (LEAP3000X HR) was investigated using a Fe-Cu binary model alloy. Solute copper atoms in ferritic iron preferentially field evaporate because of their significantly lower evaporation field than the matrix iron, and thus, the apparent concentration of solute copper tends to be lower than the actual concentration. However, in voltage-mode, the apparent concentration was higher than the actual concentration at 40 K or less due to a detection loss of matrix iron, and the concentration decreased with increasing specimen temperature due to the preferential evaporation of solute copper. On the other hand, in laser-mode, the apparent concentration never exceeded the actual concentration, even at lower temperatures (20 K), and this mode showed better quantitative performance over a wide range of specimen temperatures. These results indicate that the pulsed laser atom probe prevents both detection loss and preferential evaporation under a wide range of measurement conditions.

  7. Enhanced radiometric detection of Mycobacterium paratuberculosis by using filter-concentrated bovine fecal specimens

    International Nuclear Information System (INIS)

    Collins, M.T.; Kenefick, K.B.; Sockett, D.C.; Lambrecht, R.S.; McDonald, J.; Jorgensen, J.B.

    1990-01-01

    A commercial radiometric medium, BACTEC 12B, was modified by addition of mycobactin, egg yolk suspension, and antibiotics (vancomycin, amphotericin B, and nalidixic acid). Decontaminated bovine fecal specimens were filter concentrated by using 3-microns-pore-size, 13-mm-diameter polycarbonate filters, and the entire filter was placed into the radiometric broth. Comparison of the radiometric technique with conventional methods on 603 cattle from 9 Mycobacterium paratuberculosis-infected herds found that of 75 positive specimens, the radiometric technique detected 92% while conventional methods detected 60% (P less than 0.0005). Only 3.9% of radiometric cultures were contaminated. To measure the effect of filter concentration of specimens on the detection rate, 5 cattle with minimal and 5 with moderate ileum histopathology were sampled weekly for 3 weeks. M. paratuberculosis was detected in 33.3% of nonfiltered specimens and 76.7% of filtered specimens (P less than 0.005). Detection rates were directly correlated with the severity of disease, and the advantage of specimen concentration was greatest on fecal specimens from cattle with low-grade infections. Detection times were also correlated with infection severity: 13.4 +/- 5.9 days with smear-positive specimens, 27.9 +/- 8.7 days with feces from cows with typical subclinical infections, and 38.7 +/- 3.8 days with fecal specimens from cows with low-grade infections. Use of a cocktail of vancomycin, amphotericin B, and nalidixic acid for selective suppression of nonmycobacterial contaminants was better than the commercial product PANTA (Becton Dickinson Microbiologic Systems, Towson, Md.) only when specimens contained very low numbers of M. paratuberculosis

  8. Influence of impacts on static and low-cycle fatigue characteristics of composite specimens (Draft)

    NARCIS (Netherlands)

    Walters, C.L.

    2012-01-01

    This paper describes the effect of impacts on the possible reduction of the structural characteristics and damage growth of graphite-epoxy specimens. The considered specimens are undamaged specimens and specimens impacted with two different energy levels. In particular, barely visible impact damage

  9. Effects of intraoperative electron irradiation in the dog on cell turnover in intact and surgically-anastomosed aorta and intestine

    International Nuclear Information System (INIS)

    Sindelar, W.F.; Morrow, B.M.; Travis, E.L.; Tepper, J.; Merkel, A.B.; Kranda, K.; Terrill, R.

    1983-01-01

    Adults dogs were subjected to laparotomy and intraoperative electron irradiation after division and reanastomosis of aorta or after construction of a blind loop of small intestine having a transverse suture line and an end-to-side anastomosis. Dogs received intraoperative irradiation of both intact and anastomosed aorta or intestine in doses of 0, 2000, 3000, or 4500 rad. Animals were sacrificed at seven days or three months following treatment. At 24 hours prior to sacrifice, dogs received 5 mCi tritiated thymidine intravenously. Irradiated and non-irradiated segments of aorta and small intestine, including intact and anastomotic regions, were analyzed for tritiated thymidine incorporation and were subjected to autoradiography. Incorporation studies showed diminution in tritiated thymidine uptake by irradiated portions of aorta and small intestine, in both intact and anastomotic regions. Autoradiograms revealed that irradiated areas of intact or anastomotic aorta or intestine had diminished labeling of stromal cells, suggesting a lowered cell proliferative capacity of irradiated tissue compared to non-irradiated portions. Inflammatory cells showed similar labeling indices in irradiated and non-irradiated tissues, both intact and surgically-manipulated, suggesting that irradiation does not significantly affect a subsequent local inflammatory response. Radiation-induced decreases in tritiated thymidine incoporation in irradiated aorta and small intestine were generally more marked at seven days than at three months following irradiation, suggesting that radiation-induced depression of cell turnover rates decreases with time

  10. Bireflectance imaging of coal and carbon specimens

    Energy Technology Data Exchange (ETDEWEB)

    Crelling, J.C. [Department of Geology, 1259 Lincoln Drive, Southern Illinois University, Carbondale, Illinois 62901 (United States); Glasspool, I.J.; Gibbins, J.R.; Seitz, M. [Department of Mechanical Engineering, Imperial College, Exhibition Road, London, SW7 2BX (United Kingdom)

    2005-11-10

    Although bireflectance measurements are routine, to date they have been limited to selected single point measurements. This study uses a 360{sup o} rotating polarizer in the incident light path combined with digital imaging to map the optical bireflectance of a polished specimen over the complete field of view, a system herein referred to as 'Bireflectance Imaging of Coal and Carbon Specimens' (BRICCS). True maximum reflectance maps and maps of polarizer angle for maximum reflectance (to identify co-ordered regions) are obtainable from the same data. A variety of coal, coke, char, graphite, and carbon/carbon specimens have been examined with the BRICCS system and the results demonstrate that the system can produce accurate maximum and apparent minimum reflectance, bireflectance, and extinction angle images. For example, flakes of natural graphite show no bireflectance along their long axis except in areas that have been strained. The images are maps showing the value of every pixel that has been calibrated by mineral reflectance standards. The maps are unique in that they show fields of view that cannot be seen by normal viewing through the microscope. For example, the bireflectance maps show the maximum difference between the maximum and apparent minimum reflectance for each of the million pixels at twenty orientations of the polarizer. (author)

  11. Crack Propagation on ESE(T) Specimens Strengthened with CFRP Sheets

    DEFF Research Database (Denmark)

    Hansen, Christian Skodborg; Jensen, Peter Holmstrøm; Dyrelund, Jens

    2009-01-01

    In this paper fatigue tests on side notched steel test specimens strengthened with adhesive bonded fibre reinforced polymer (FRP) sheets are presented. The specimens are subject to crack growth both in the steel and bond line. Influence of the load ratio and initial crack length on the overall...

  12. The Fate of Dissolved Creosote Compounds in an Intact Fratured Clay Column

    DEFF Research Database (Denmark)

    Broholm, Kim; Arvin, Erik; Hansen, Asger

    1995-01-01

    The fate of 16 different organics typical for creosote was studied under aerobic conditions in a large intact fractured clay column experiment. Some of the organics (benzene, toluene, o-xylene, phenol, and o-cresol) were transported at the same rate as bromide through the fractured clay, whereas ...

  13. Morphing methods to parameterize specimen-specific finite element model geometries.

    Science.gov (United States)

    Sigal, Ian A; Yang, Hongli; Roberts, Michael D; Downs, J Crawford

    2010-01-19

    Shape plays an important role in determining the biomechanical response of a structure. Specimen-specific finite element (FE) models have been developed to capture the details of the shape of biological structures and predict their biomechanics. Shape, however, can vary considerably across individuals or change due to aging or disease, and analysis of the sensitivity of specimen-specific models to these variations has proven challenging. An alternative to specimen-specific representation has been to develop generic models with simplified geometries whose shape is relatively easy to parameterize, and can therefore be readily used in sensitivity studies. Despite many successful applications, generic models are limited in that they cannot make predictions for individual specimens. We propose that it is possible to harness the detail available in specimen-specific models while leveraging the power of the parameterization techniques common in generic models. In this work we show that this can be accomplished by using morphing techniques to parameterize the geometry of specimen-specific FE models such that the model shape can be varied in a controlled and systematic way suitable for sensitivity analysis. We demonstrate three morphing techniques by using them on a model of the load-bearing tissues of the posterior pole of the eye. We show that using relatively straightforward procedures these morphing techniques can be combined, which allows the study of factor interactions. Finally, we illustrate that the techniques can be used in other systems by applying them to morph a femur. Morphing techniques provide an exciting new possibility for the analysis of the biomechanical role of shape, independently or in interaction with loading and material properties. Copyright 2009 Elsevier Ltd. All rights reserved.

  14. Residual stress state in pipe cut ring specimens for fracture toughness testing

    Energy Technology Data Exchange (ETDEWEB)

    Damjanovic, Darko [J.J. Strossmayer Univ. of Osijek, Slavonski Brod (Croatia). Mechanical Engineering Faculty; Kozak, Drazan [Zagreb Univ. (Croatia). Dept. for Mechanical Design; Marsoner, Stefan [Materials Center, Leoben (Austria).; Gubeljak, Nenad [Maribor Univ. (Slovenia). Chair of Mechanics

    2017-07-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  15. Residual stress state in pipe cut ring specimens for fracture toughness testing

    International Nuclear Information System (INIS)

    Damjanovic, Darko; Kozak, Drazan; Marsoner, Stefan; Gubeljak, Nenad

    2017-01-01

    Thin-walled pipes are not suitable for measuring fracture toughness parameters of vital importance because longitudinal crack failure is the most common failure mode in pipes. This is due to the impossibility to manufacture standard specimens for measuring fracture toughness, such as SENB or CT specimens, from the thin wall of the pipe. Previous works noticed this problem, but until now, a good and convenient solution has not been found or developed. To overcome this problem, very good alternative solution was proposed, the so-called pipe ring notched bend specimen (PRNB) [1-5]. Until now, only the idealized geometry PRNB specimen is analyzed, i. e., a specimen which is not cut out from an actual pipe but produced from steel plate. Based on that, residual stresses are neglected along with the imperfections in geometry (elliptical and eccentricity). The aim of this research is to estimate the residual stress state(s) in real pipes used in the boiler industry produced by hot rolling technique. These types of pipes are delivered only in normalized condition, but not stress relieved. Therefore, there are residual stresses present due to the manufacturing technique, but also due to uneven cooling after the production process. Within this paper, residual stresses are estimated by three methods: the incremental hole drilling method (IHMD), X-ray diffraction (XRD) and the splitting method (SM). Knowing the residual stress state in the ring specimen, it is possible to assess their impact on fracture toughness measured on the corresponding PRNB specimen(s).

  16. An Inset CT Specimen for Evaluating Fracture in Small Samples of Material

    Science.gov (United States)

    Yahyazadehfar, M.; Nazari, A.; Kruzic, J.J.; Quinn, G.D.; Arola, D.

    2013-01-01

    In evaluations on the fracture behavior of hard tissues and many biomaterials, the volume of material available to study is not always sufficient to apply a standard method of practice. In the present study an inset Compact Tension (inset CT) specimen is described, which uses a small cube of material (approximately 2×2×2 mm3) that is molded within a secondary material to form the compact tension geometry. A generalized equation describing the Mode I stress intensity was developed for the specimen using the solutions from a finite element model that was defined over permissible crack lengths, variations in specimen geometry, and a range in elastic properties of the inset and mold materials. A validation of the generalized equation was performed using estimates for the fracture toughness of a commercial dental composite via the “inset CT” specimen and the standard geometry defined by ASTM E399. Results showed that the average fracture toughness obtained from the new specimen (1.23 ± 0.02 MPa•m0.5) was within 2% of that from the standard. Applications of the inset CT specimen are presented for experimental evaluations on the crack growth resistance of dental enamel and root dentin, including their fracture resistance curves. Potential errors in adopting this specimen are then discussed, including the effects of debonding between the inset and molding material on the estimated stress intensity distribution. Results of the investigation show that the inset CT specimen offers a viable approach for studying the fracture behavior of small volumes of structural materials. PMID:24268892

  17. Tolerance of a standard intact protein formula versus a partially hydrolyzed formula in healthy, term infants

    Directory of Open Access Journals (Sweden)

    Marunycz John D

    2009-06-01

    Full Text Available Abstract Background Parents who perceive common infant behaviors as formula intolerance-related often switch formulas without consulting a health professional. Up to one-half of formula-fed infants experience a formula change during the first six months of life. Methods The objective of this study was to assess discontinuance due to study physician-assessed formula intolerance in healthy, term infants. Infants (335 were randomized to receive either a standard intact cow milk protein formula (INTACT or a partially hydrolyzed cow milk protein formula (PH in a 60 day non-inferiority trial. Discontinuance due to study physician-assessed formula intolerance was the primary outcome. Secondary outcomes included number of infants who discontinued for any reason, including parent-assessed. Results Formula intolerance between groups (INTACT, 12.3% vs. PH, 13.7% was similar for infants who completed the study or discontinued due to study physician-assessed formula intolerance. Overall study discontinuance based on parent- vs. study physician-assessed intolerance for all infants (14.4 vs.11.1% was significantly different (P = 0.001. Conclusion This study demonstrated no difference in infant tolerance of intact vs. partially hydrolyzed cow milk protein formulas for healthy, term infants over a 60-day feeding trial, suggesting nonstandard partially hydrolyzed formulas are not necessary as a first-choice for healthy infants. Parents frequently perceived infant behavior as formula intolerance, paralleling previous reports of unnecessary formula changes. Trial Registration clinicaltrials.gov: NCT00666120

  18. Clonal expansion of genome-intact HIV-1 in functionally polarized Th1 CD4+ T cells.

    Science.gov (United States)

    Lee, Guinevere Q; Orlova-Fink, Nina; Einkauf, Kevin; Chowdhury, Fatema Z; Sun, Xiaoming; Harrington, Sean; Kuo, Hsiao-Hsuan; Hua, Stephane; Chen, Hsiao-Rong; Ouyang, Zhengyu; Reddy, Kavidha; Dong, Krista; Ndung'u, Thumbi; Walker, Bruce D; Rosenberg, Eric S; Yu, Xu G; Lichterfeld, Mathias

    2017-06-30

    HIV-1 causes a chronic, incurable disease due to its persistence in CD4+ T cells that contain replication-competent provirus, but exhibit little or no active viral gene expression and effectively resist combination antiretroviral therapy (cART). These latently infected T cells represent an extremely small proportion of all circulating CD4+ T cells but possess a remarkable long-term stability and typically persist throughout life, for reasons that are not fully understood. Here we performed massive single-genome, near-full-length next-generation sequencing of HIV-1 DNA derived from unfractionated peripheral blood mononuclear cells, ex vivo-isolated CD4+ T cells, and subsets of functionally polarized memory CD4+ T cells. This approach identified multiple sets of independent, near-full-length proviral sequences from cART-treated individuals that were completely identical, consistent with clonal expansion of CD4+ T cells harboring intact HIV-1. Intact, near-full-genome HIV-1 DNA sequences that were derived from such clonally expanded CD4+ T cells constituted 62% of all analyzed genome-intact sequences in memory CD4 T cells, were preferentially observed in Th1-polarized cells, were longitudinally detected over a duration of up to 5 years, and were fully replication- and infection-competent. Together, these data suggest that clonal proliferation of Th1-polarized CD4+ T cells encoding for intact HIV-1 represents a driving force for stabilizing the pool of latently infected CD4+ T cells.

  19. Uptake and clearance of plutonium-238 from intact liver and liver cells transplanted into fat pads of F344/N rats

    International Nuclear Information System (INIS)

    Brooks, A.L.; Guilmette, R.A.; Hahn, F.F.; Jirtle, R.L.

    1985-01-01

    An understanding of the role of liver cells and the intact liver in plutonium biokinetics is needed. Liver cells were isolated from rats, injected into fat pads of recipient rats, and allowed 21 days to form cell colonies. Rats then received a single intraperitoneal injection of 1 μCi 238 Pu-citrate and were serially sacrificed. Uptake, retention, and distribution of Pu in intact liver and in liver cells growing in fat pads were determined. Intact liver cells took up about twice as much 238 Pu as liver cells transplanted into fat pads. However, the retention kinetics of Pu were similar for both the liver cells in the fat pads and the intact liver cells when the retention was expressed as activity per cell. 4 references, 1 figure, 1 table

  20. Thinning of specimens for examination under the electron microscope

    International Nuclear Information System (INIS)

    Franks, J.

    1982-01-01

    Heretofore specimens have been thinned to penetration for examination by electron microscopy techniques, by ion erosion techniques. A more rapid technique is disclosed employing a beam or beams comprised solely of neutral particles. In tests carried out using this technique the sputtering rate from a sample specimen has been shown to be several percentages greater using a neutral source than from an ion source with the same flux density. (author)

  1. Special fracture mechanics specimens for multilayer plastic pipes testing

    Czech Academy of Sciences Publication Activity Database

    Hutař, Pavel; Šestáková, Lucie; Knésl, Zdeněk; Nezbedová, E.; Náhlík, Luboš

    2009-01-01

    Roč. 28, č. 8 (2009), s. 785-792 ISSN 0142-9418 R&D Projects: GA ČR GA106/09/0279; GA ČR GC101/09/J027 Institutional research plan: CEZ:AV0Z20410507 Keywords : Multilayer plastic pipes * C-type specimen * K-calibration * Fracture toughness * Slow crack growth * Non-homogenous specimens Subject RIV: JL - Material s Fatigue, Friction Mechanics Impact factor: 1.667, year: 2009

  2. Use of miniature tensile specimen and video extensometer for measurement of mechanical properties

    International Nuclear Information System (INIS)

    Kumar, Kundan; Pooleery, Arun; Madhusoodanan, K.

    2014-08-01

    Miniaturisation of the tensile test specimen below the sub-size level poses various challenges, such as conformity of specimen to various acceptance criteria as per standard test specimen, aspect ratio, minimum number of grains required in a gauge cross-section, fabrication for uniformity in metrological values, etc. Apart from these, measurement of strain over a very limited available space on the test specimen is another practical challenge. Despite these limitations, miniature specimen testing is increasingly being used worldwide these days. The driving forces behind increasing use of miniature test techniques are new material development, assuring fitness of component after in-service-inspection, low dose of radiation exposure due to smaller dimensions of test specimens etc. However, the evaluation of mechanical properties from a miniature tensile test has a greater advantage over the other miniature novel test techniques, such as small punch test, ABI, miniature fatigue and impact tests etc., as it is a direct method of measurement of mechanical properties. This report covers various aspects of miniature tensile test methodologies, which include geometrical design of specimen having gauge length of 3-5 mm, fabrication, development of special fixtures for gripping the test specimens, and use of optical method for strain measurement. The geometrical design of the specimen and its behaviour over application of tensile load has been established using FEM analysis. A good agreement between conventional and miniature test results exemplifies the potential of the miniature tensile test technique. (author)

  3. Fabrication and testing of prestressed composite rotor blade spar specimens

    Science.gov (United States)

    Gleich, D.

    1974-01-01

    Prestressed composite spar specimens were fabricated and evaluated by crack propagation and ballistic penetration tests. The crack propagation tests on flawed specimens showed that the prestressed composite spar construction significantly suppresses crack growth. Damage from three high velocity 30 caliber projectile hits was confined to three small holes in the ballistic test specimen. No fragmentation or crack propagation was observed indicating good ballistic damage resistance. Rotor attachment approaches and improved structural performance configurations were identified. Design theory was verified by tests. The prestressed composite spar configuration consisted of a compressively prestressed high strength ARDEFORM 301 stainless steel liner overwrapped with pretensioned S-994 fiberglass.

  4. Quantitative x-ray microanalysis in an AEM: instrumental considerations and applications to materials science

    International Nuclear Information System (INIS)

    Zaluzec, N.J.

    1979-01-01

    There are a wide variety of instrumental problems which are present to some degree in all AEM instruments. The nature and magnitude of these artifacts can in some instances preclude the simple quantitative interpretation of the recorded x-ray emission spectrum using a thin-film electron excitation model; however, by judicious modifications to the instrument these complications can be effectively eliminated. The specific operating conditions of the microscope necessarily vary from one analysis to another depending on the type of specimen and experiment being performed. In general, however, the overall performance of the AEM system during x-ray analysis is optimized using the highest attainable incident electron energy; selecting the maximum probe diameter and probe current consistent with experimental limitations; and positioning the x-ray detector in a geometry such that it records information from the electron entrance surface of the specimen

  5. On a specimen of Lumbricus terrestris, L. with bifurcated tail

    NARCIS (Netherlands)

    Horst, R.

    1886-01-01

    In the last number of the »Annals and Magazine of Nat. History” (Dec. 1885), I find a notice of Prof. Jeffrey Bell about two Lumbrici with bifid hinder ends, one specimen belonging to L. terrestris, the other to L. foetidus; moreover he mentions a specimen, presenting a similar remarquable

  6. Radionuclide sorption on crushed and intact granitic rock

    International Nuclear Information System (INIS)

    Eriksen, Tryggve E.; Locklund, Birgitta

    1989-05-01

    The specific surface areas and distribution ratios for sorption of 85 Sr, 137 Cs and 152 Eu were measured for crushed and intact granite rock. The experimental data can be accommodated by a sorption model encompassing sorption on outer and inner surface. It is clearly demonstrated that the time required to obtain reliable Kd-values for the sorption of strongly sorbing radionuclides like 152 Eu is very long due to solution depletion and slow diffusion into the rock. A combination of surface area measurements and batch sorption with small particles may therefore be preferable when studying strongly sorbing nuclides. (authors) (17 figs., 6 tabs.)

  7. Experimental and Numerical Investigations on Feasibility and Validity of Prismatic Rock Specimen in SHPB

    Directory of Open Access Journals (Sweden)

    Xibing Li

    2016-01-01

    Full Text Available The paper presents experimental and numerical studies on the feasibility and validity of using prismatic rock specimens in split Hopkinson pressure bar (SHPB test. Firstly, the experimental tests are conducted to evaluate the stress and strain uniformity in the prismatic specimens during impact loading. The stress analysis at the ends of the specimen shows that stress equilibrium can be achieved after about three wave reflections in the specimen, and the balance can be well maintained for a certain time after peak stress. The strain analysis reveals that the prismatic specimen deforms uniformly during the dynamic loading period. Secondly, numerical simulation is performed to further verify the stress and strain uniformity in the prismatic specimen in SHPB test. It indicates that the stress equilibrium can be achieved in prismatic specimen despite a certain degree of stress concentration at the corners. The comparative experiments demonstrate that the change of specimen shape has no significant effect on dynamic responses and failure patterns of the specimen. Finally, a dynamic crack propagation test is presented to show the application of the present work in studying fracturing mechanisms under dynamic loading.

  8. Small specimen technique for assessing mechanical properties of metallic components

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E., E-mail: rmlobo@ipen.br, E-mail: morcelliae@gmail.com [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2017-11-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  9. Small specimen technique for assessing mechanical properties of metallic components

    International Nuclear Information System (INIS)

    Lobo, Raquel M.; Andrade, Arnaldo H.P.; Morcelli, Aparecido E.

    2017-01-01

    Small Punch Test (SPT) is one of the most promising techniques of small specimen test, which was originally applied in testing of irradiated materials in nuclear engineering. Then it was introduced to other fields as an almost nondestructive method to measure the local mechanical properties that are difficult to be obtained using conventional mechanical tests. Most studies to date are focused on metallic materials, although SPT applications are recently spreading to other materials. The small punch test (SPT) employs small-sized specimens (for example, samples measuring 8 mm in diameter and 0.5 mm thick). The specimen is firmly clamped between two circular dies and is bi-axially strained until failure into a circular hole using a hemispherical punch. The 'load-punch displacement' record can be used to estimate the yield strength, the ultimate tensile strength, the tensile elongation, and the temperature of the ductile-to-brittle transition. Recently, some researchers are working on the use of miniature notched or pre-cracked specimens (denoted as p-SPT) to validate its geometry and dimensions for obtaining the fracture properties of metallic materials. In a first approach, the technique makes it possible to convert primary experimental data into conventional mechanical properties of a massive specimen. In this paper a comprehensive review of the different STP applications is presented with the aim of clarifying its usefulness. (author)

  10. Testing machine for fatigue crack kinetic investigation in specimens under bending

    International Nuclear Information System (INIS)

    Panasyuk, V.V.; Ratych, L.V.; Dmytrakh, I.N.

    1978-01-01

    A kinematic diagram of testing mashine for the investigation of fatigue crack kinetics in prismatic specimens, subjected to pure bending is described. Suggested is a technique of choosing an optimum ratio of the parameters of ''the testing machine-specimen'' system, which provide the stabilization of the stress intensity coefficient for a certain region of crack development under hard loading. On the example of the 40KhS and 15Kh2MFA steel specimens the pliability of the machine constructed according to the described diagram and designed for the 30ONxm maximum bending moment. The results obtained can be used in designing of the testing machines for studying pure bending under hard loading and in choosing the sizes of specimens with rectangular cross sections for investigations into the kinetics of the fatigue crack

  11. Quantitative Analysis of Signaling Networks across Differentially Embedded Tumors Highlights Interpatient Heterogeneity in Human Glioblastoma

    Science.gov (United States)

    2015-01-01

    Glioblastoma multiforme (GBM) is the most aggressive malignant primary brain tumor, with a dismal mean survival even with the current standard of care. Although in vitro cell systems can provide mechanistic insight into the regulatory networks governing GBM cell proliferation and migration, clinical samples provide a more physiologically relevant view of oncogenic signaling networks. However, clinical samples are not widely available and may be embedded for histopathologic analysis. With the goal of accurately identifying activated signaling networks in GBM tumor samples, we investigated the impact of embedding in optimal cutting temperature (OCT) compound followed by flash freezing in LN2 vs immediate flash freezing (iFF) in LN2 on protein expression and phosphorylation-mediated signaling networks. Quantitative proteomic and phosphoproteomic analysis of 8 pairs of tumor specimens revealed minimal impact of the different sample processing strategies and highlighted the large interpatient heterogeneity present in these tumors. Correlation analyses of the differentially processed tumor sections identified activated signaling networks present in selected tumors and revealed the differential expression of transcription, translation, and degradation associated proteins. This study demonstrates the capability of quantitative mass spectrometry for identification of in vivo oncogenic signaling networks from human tumor specimens that were either OCT-embedded or immediately flash-frozen. PMID:24927040

  12. Sediment carbon and nutrient fluxes from cleared and intact temperate mangrove ecosystems and adjacent sandflats.

    Science.gov (United States)

    Bulmer, Richard H; Schwendenmann, Luitgard; Lohrer, Andrew M; Lundquist, Carolyn J

    2017-12-01

    The loss of mangrove ecosystems is associated with numerous impacts on coastal and estuarine function, including sediment carbon and nutrient cycling. In this study we compared in situ fluxes of carbon dioxide (CO 2 ) from the sediment to the atmosphere, and fluxes of dissolved inorganic nutrients and oxygen across the sediment-water interface, in intact and cleared mangrove and sandflat ecosystems in a temperate estuary. Measurements were made 20 and 25months after mangrove clearance, in summer and winter, respectively. Sediment CO 2 efflux was over two-fold higher from cleared than intact mangrove ecosystems at 20 and 25months after mangrove clearance. The higher CO 2 efflux from the cleared site was explained by an increase in respiration of dead root material along with sediment disturbance following mangrove clearance. In contrast, sediment CO 2 efflux from the sandflat site was negligible (≤9.13±1.18mmolm -2 d -1 ), associated with lower sediment organic matter content. The fluxes of inorganic nutrients (NH 4 + , NO x and PO 4 3- ) from intact and cleared mangrove sediments were low (≤20.37±18.66μmolm -2 h - 1 ). The highest NH 4 + fluxes were measured at the sandflat site (69.21±13.49μmolm -2 h - 1 ). Lower inorganic nutrient fluxes within the cleared and intact mangrove sites compared to the sandflat site were associated with lower abundance of larger burrowing macrofauna. Further, a higher fraction of organic matter, silt and clay content in mangrove sediments may have limited nutrient exchange. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Collagen fibril size and crimp morphology in ruptured and intact Achilles tendons

    DEFF Research Database (Denmark)

    Magnusson, S P; Qvortrup, K; Larsen, Jytte Overgaard

    2002-01-01

    tendons. Crimp angle did not display any region-specific differences, or any difference between the rupture and intact tendons. In conclusion, these data suggest that although crimp morphology is unchanged there appears to be a site-specific loss of larger fibrils in the core and periphery of the Achilles...

  14. 46 CFR 173.020 - Intact stability standards: Counterballasted and non-counterballasted vessels.

    Science.gov (United States)

    2010-10-01

    ...) SUBDIVISION AND STABILITY SPECIAL RULES PERTAINING TO VESSEL USE Lifting § 173.020 Intact stability standards... vessel that is not equipped to counter-ballast while lifting must be shown by design calculations to... and crane radius. (b) Each vessel must have a righting arm curve with the following characteristics...

  15. Forest loss in protected areas and intact forest landscapes : A global analysis

    NARCIS (Netherlands)

    Heino, Matias; Kummu, Matti; Makkonen, Marika; Mulligan, Mark; Verburg, Peter H.; Jalava, Mika; Räsänen, Timo A.

    2015-01-01

    In spite of the high importance of forests, global forest loss has remained alarmingly high during the last decades. Forest loss at a global scale has been unveiled with increasingly finer spatial resolution, but the forest extent and loss in protected areas (PAs) and in large intact forest

  16. Electronprobe X-ray microanalysis of biological specimens improvement of a number of quantification procedures

    International Nuclear Information System (INIS)

    Boekestein, A.

    1984-01-01

    In this thesis an investigation is described to establish which quantification procedures can be used in the X-ray microanalysis of biological specimens. Two classes of specimens have been distinguished from each other, i.e. thick specimens (opaque to the beam electrons) and thin specimens (transparent to the beam electrons). (Auth.)

  17. Cutaneous mast cell maturation does not depend on an intact bone marrow microenvironment

    International Nuclear Information System (INIS)

    Charley, M.R.; Mikhael, A.; Sontheimer, R.D.; Gilliam, J.N.; Bennett, M.

    1984-01-01

    A study was made to determine whether the maturation of murine cutaneous mast cells from stem cells depends on an intact bone marrow microenvironment. Normal bone marrow cells (+/+) were infused into 2 groups of mast cell-deficient mice: WBB6F1-W/Wv mice and 89 Sr-pretreated W/Wv mice. 89 Sr is a long-lived bone-seeking radioisotope which provides continuous irradiation of the marrow and thereby ablates the marrow microenvironment. Skin biopsies revealed that the 89 Sr-pretreated mice and the controls had repopulated their skin with mast cells equally well. Natural killer cell function was significantly depressed in the 89 Sr-treated mice, confirming that the marrow microenvironment had been functionally altered. It appears that, although the precursors for cutaneous mast cells are marrow derived, they do not need an intact marrow microenvironment for maturation

  18. Analytical characteristics and comparative evaluation of Aptima HCV quant Dx assay with the Abbott RealTime HCV assay and Roche COBAS AmpliPrep/COBAS TaqMan HCV quantitative test v2.0.

    Science.gov (United States)

    Worlock, A; Blair, D; Hunsicker, M; Le-Nguyen, T; Motta, C; Nguyen, C; Papachristou, E; Pham, J; Williams, A; Vi, M; Vinluan, B; Hatzakis, A

    2017-04-04

    The Aptima HCV Quant Dx assay (Aptima assay) is a fully automated quantitative assay on the Panther® system. This assay is intended for confirmation of diagnosis and monitoring of HCV RNA in plasma and serum specimens. The purpose of the testing described in this paper was to evaluate the performance of the Aptima assay. The analytical sensitivity, analytical specificity, precision, and linearity of the Aptima assay were assessed. The performance of the Aptima assay was compared to two commercially available HCV assays; the Abbott RealTime HCV assay (Abbott assay, Abbott Labs Illinois, USA) and the Roche COBAS Ampliprep/COBAS Taqman HCV Quantitative Test v2.0 (Roche Assay, Roche Molecular Systems, Pleasanton CA, USA). The 95% Lower Limit of Detection (LoD) of the assay was determined from dilutions of the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) and HCV positive clinical specimens in HCV negative human plasma and serum. Probit analysis was performed to generate the 95% predicted detection limits. The Lower Limit of Quantitation (LLoQ) was established for each genotype by diluting clinical specimens and the 2nd HCV WHO International Standard (NIBSC 96/798 genotype 1) in HCV negative human plasma and serum. Specificity was determined using 200 fresh and 536 frozen HCV RNA negative clinical specimens including 370 plasma specimens and 366 serum specimens. Linearity for genotypes 1 to 6 was established by diluting armored RNA or HCV positive clinical specimens in HCV negative serum or plasma from 8.08 log IU/mL to below 1 log IU/mL. Precision was tested using a 10 member panel made by diluting HCV positive clinical specimens or spiking armored RNA into HCV negative plasma and serum. A method comparison was conducted against the Abbott assay using 1058 clinical specimens and against the Roche assay using 608 clinical specimens from HCV infected patients. In addition, agreement between the Roche assay and the Aptima assay using specimens with low

  19. Palladium nanoparticles exposure: Evaluation of permeation through damaged and intact human skin.

    Science.gov (United States)

    Larese Filon, Francesca; Crosera, Matteo; Mauro, Marcella; Baracchini, Elena; Bovenzi, Massimo; Montini, Tiziano; Fornasiero, Paolo; Adami, Gianpiero

    2016-07-01

    The intensified use of palladium nanoparticles (PdNPs) in many chemical reactions, jewellery, electronic devices, in car catalytic converters and in biomedical applications lead to a significant increase in palladium exposure. Pd can cause allergic contact dermatitis when in contact with the skin. However, there is still a lack of toxicological data related to nano-structured palladium and information on human cutaneous absorption. In fact, PdNPs, can be absorbed through the skin in higher amounts than bulk Pd because NPs can release more ions. In our study, we evaluated the absorption of PdNPs, with a size of 10.7 ± 2.8 nm, using intact and damaged human skin in Franz cells. 0.60 mg cm(-2) of PdNPs were applied on skin surface for 24 h. Pd concentrations in the receiving solutions at the end of experiments were 0.098 ± 0.067 μg cm(-2) and 1.06 ± 0.44 μg cm(-2) in intact skin and damaged skin, respectively. Pd flux permeation after 24 h was 0.005 ± 0.003 μg cm(-2) h(-1) and 0.057 ± 0.030 μg cm(-2) h(-1) and lag time 4.8 ± 1.7 and 4.2 ± 3.6 h, for intact and damaged skin respectively. This study indicates that Pd can penetrate human skin. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Isotope inequilibrium of glucose metabolites in intact cells and particlefree supernatants of Ehrlich ascites tumor

    International Nuclear Information System (INIS)

    Daehnfeldt, J.L.; Winge, P.

    1975-01-01

    With an enzyme degradative technique, isotope inequilibrium of glucose metabolites was demonstrated in intact cells and particle-free supernatants of Ehrlich ascites tumor using I- 14 C-glucose as tracer. Inequilibrium was found between glucose and glucose-6-phosphate, glucose and fructose-6-phosphate, glucose and 6-phosphogluconate, while glucose-6-phosphate and fructose-6-phosphate were found to be in near equilibrium within the incubation time investigated. Glucose and lactate were found to be in near equilibrium after 8 min in intact cells. Calculations based on the equilibrium levels found, showed that these inequilibria could not be explained by the effects of the pentose cycle. (U.S.)

  1. Boron-11 MRI and MRS of intact animals infused with a boron neutron capture agent

    International Nuclear Information System (INIS)

    Kabalka, G.W.; Davis, M.; Bendel, P.

    1988-01-01

    Boron neutron capture therapy (BNCT) depends on the delivery of boron-containing drugs to a targeted lesion. Currently, the verification and quantification of in vivo boron content is a difficult problem. Boron-11 spectroscopy was utilized to confirm the presence of a dimeric sulfhydryl dodecaborane BNCT agent contained in an intact animal. Spectroscopy experiments revealed that the decay time of transverse magnetization of the boron-11 spins was less than 1 ms which precluded the use of a 2DFT imaging protocol. A back-projection protocol was developed and utilized to generate the first boron-11 image of a BNCT agent in the liver of an intact Fisher 344 rat

  2. Design and construction of OGL-1 Specimen Transfer System

    International Nuclear Information System (INIS)

    Nakamura, Kunio; Saruta, Tohru; Nabeya, Hideaki; Nakagaki, Shogo; Nishizaki, Tadashi.

    1977-11-01

    OGL-1 is the first high temperature gas in-pile loop in Japan, which is installed in JMTR of Oarai Research Establishment, JAERI. As the JMTR is the PWR type, specimens must be set in the loop with a remote control system ''OGL-1 Specimen Transfer System'' because of the needs for moisture prevention and radiation shielding. Described in this report are design philosophy, loop development, problems in construction, inspection and operation. (auth.)

  3. Breast surgical specimen radiographs: How reliable are they?

    International Nuclear Information System (INIS)

    Britton, P.D.; Sonoda, L.I.; Yamamoto, A.K.; Koo, B.; Soh, E.; Goud, A.

    2011-01-01

    Radiography of the excised surgical specimen following wire guided localisation of impalpable breast lesions is standard surgical practice. The aims of the study were to establish the reliability of the breast specimen radiograph (SR) in determining lesion excision and to determine whether the radiographic margin correlated with the histological margin. The clinical, imaging, SR and pathological details of 106 patients with a pre-operative diagnosis of breast cancer were retrospectively reviewed. The reliability of orientation was estimated and the appearance and distance from the mammographic abnormality to each radial margin were measured and correlated with surgical histological findings. The overall accuracy of the specimen radiograph in determining whether the mammographic lesion was present was 99%. The SR could be orientated 'very reliably' or 'reliably' in 80% of patients however in only 48% of patients did the closest margin on the SR correspond with the same nearest margin at final histology. A maximum measurement of 11 mm or more from the lesion to the specimen edge was associated with a 77% likelihood of having a clear final histological margin (taken as 5 mm or more) and if <11 mm a 58% chance of having involved final histological margins. There was however a wide overlap in the results with patients having an apparently wide SR margin but histologically involved margins and vice versa. The SR is reliable at determining whether the target lesion has been removed. The correlation of SR margin orientation and measurement with final histological measurement is however far less reliable.

  4. Grips for testing of electrical characteristics of a specimen under a mechanical load

    Science.gov (United States)

    Briggs, Timothy; Loyola, Bryan

    2018-04-24

    Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

  5. Urine specimen validity test for drug abuse testing in workplace and court settings.

    Science.gov (United States)

    Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun

    2018-01-01

    In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.

  6. Lesion measurement in non-radioactive DNA by quantitative gel electrophoresis

    International Nuclear Information System (INIS)

    Sutherland, J.C.; Chen, Chun Zhang; Emrick, A.; Hacham, H; Monteleone, D.; Ribeiro, E.; Trunk, J.; Sutherland, B.M.

    1989-01-01

    The gel electrophoresis method developed during the past ten years in our laboratories makes possible the quantitation of UV induced pyrimidine dimers, gamma ray induced single- and double-strand breaks and many other types of lesions in nanogram quantities of DNA. The DNA does not have to be labeled with radionuclides or of a particular conformation, thus facilitating the use of the method in measuring damage levels and repair rates in the DNA of intact organisms -- including man. The gel method can quantitate any lesion in DNA that either is, or can be converted to a single- or double-strand break. The formation of a strand break produces two shorter DNA molecules for each molecule that existed before the treatment that produced the break. Determining the number of breaks, and hence the number of lesions, becomes a matter of comparing the average lengths of molecules in samples differing only in lesion-induced breaks. This requires that we determine the distribution of mass of DNA on a gel as a function of its distance of migration and also the dispersion function of its distance of migration and also the dispersion function (the relationship between molecular length and distance of migration) in the gel electrophoresis system. 40 refs., 5 figs

  7. Thiel embalming fluid--a new way to revive formalin-fixed cadaveric specimens.

    Science.gov (United States)

    Hunter, Amanda; Eisma, Roos; Lamb, Clare

    2014-09-01

    By soft fixing cadavers using the Thiel embalming method, our cadavers now exhibit a greater degree of flexibility and color retention compared to that of traditional formalin-fixed cadavers. The aim of this experiment was to discover whether Thiel embalming fluid could be used to revive and soften the muscles of formalin-fixed prosected specimens. Earlier this year, two severely dehydrated formalin-fixed forearm and hand specimens were fully submerged in a tank containing Thiel embalming fluid. After a period of six months the specimens were removed from the tank and noticeable changes were observed in flexibility, quality of the tissue, and color of the specimens. © 2014 Wiley Periodicals, Inc.

  8. Elastic-plastic analysis of fracture mechanics test specimens. Part 2

    International Nuclear Information System (INIS)

    Talja, H.; Wallin, K.

    1984-12-01

    This is second part of the report of the research program 'Comparisons between computational and experimental elastic-plastic results' started at the Technical Research Centre of Finland in 1981. The first part of the research program was reported earlier and contained a two dimensional linear elastic finite element analysis of four specimen geometries (CT, RCT, ASTM-3P and Charpy-V) and testing and elastic-plastic analysis of the specimen (EGF71; 1TCT, material A 542). In this report the second part of the program containing the testing and 2-D elastic-plastic analyses of five specimens is described. The four specimen geometries mentioned above and two different materials (stainless steel AISI 304 and ferrite pressure vessel steel A533B) are considered. The following comparisons are presented in the report: load vs. load displacement curves, J-integral, crack opening displacement (COD), J vs. COD and the size of the plastic zone. The agreement between the computational and experimental results is quite good. Complete agreement can be achieved only with 3-dimensional calculation models. (author)

  9. The action of cobra venom phospholipase A2 isoenzymes towards intact human erythrocytes

    NARCIS (Netherlands)

    Roelofsen, B.; Sibenius Trip, M.; Verheij, H.M.; Zevenbergen, J.L.

    1980-01-01

    1. 1. Cobra venom phospholipase A2 from three different sources has been fractionated into different isoenzymes by DEAE ion-exchange chromatography. 2. 2. Treatment of intact human erythrocytes with the various isoenzymes revealed significant differences in the degree of phosphatidylcholine

  10. An analysis of forensic entomological specimens by Universiti Kebangsaan Malaysia.

    Science.gov (United States)

    Syamsa, R A; Ahmad, F M S; Marwi, M A; Zuha, R M; Omar, B

    2010-09-01

    This study reviews forensic entomological specimens analysed by the Department of Parasitology & Medical Entomology, Universiti Kebangsaan Malaysia for the year 2004. A total of 10 cases (6 males and 4 females) were observed for the entomological specimens. Various types of death scenes were obtained including indoor and outdoor area such as bushes field, rubbish dumping site, and aquatic areas. Identified fly species collected from the death sites were blow flies, Chrysomya megacephala, Chrysomya rufifacies and Lucilia cuprina and unknown sarcophagid larvae, with Ch. megacephala being the most common species found in the ecologically varied death scene habitats. The post-mortem interval (PMI) estimation ranged from one to five days, based on the entomological specimens collected.

  11. The effect of specimen and flaw dimensions on fracture toughness

    Energy Technology Data Exchange (ETDEWEB)

    Nevalainen, M.J. [VTT Manufacturing Technology, Espoo (Finland)

    1997-06-01

    The effect of the specimen size and geometry on fracture toughness has been investigated both by experimental tests and computational analyses. The methods for constraint description, namely T-stress, Q-parameter and Small-Scale Yielding Correction (SSYC) have been compared and applied for various geometries. A statistical treatment for the specimen thickness effect on cleavage fracture toughness has been investigated. Elliptical surface cracks were compared with straight-thickness cracks and a method for crack shape correction was presented. Based on the results, the differences in apparent fracture toughness values obtained from various specimen configurations can be better understood and taken into account. 64 refs. The thesis includes also four previous publications by author.

  12. Cerenkov and radioluminescence imaging of brain tumor specimens during neurosurgery

    Science.gov (United States)

    Spinelli, Antonello Enrico; Schiariti, Marco P.; Grana, Chiara M.; Ferrari, Mahila; Cremonesi, Marta; Boschi, Federico

    2016-05-01

    We presented the first example of Cerenkov luminescence imaging (CLI) and radioluminescence imaging (RLI) of human tumor specimens. A patient with a brain meningioma localized in the left parietal region was injected with 166 MBq of Y90-DOTATOC the day before neurosurgery. The specimens of the tumor removed during surgery were imaged using both CLI and RLI using an optical imager prototype developed in our laboratory. The system is based on a cooled electron multiplied charge coupled device coupled with an f/0.95 17-mm C-mount lens. We showed for the first time the possibility of obtaining CLI and RLI images of fresh human brain tumor specimens removed during neurosurgery.

  13. Genomic treasure troves: complete genome sequencing of herbarium and insect museum specimens.

    Science.gov (United States)

    Staats, Martijn; Erkens, Roy H J; van de Vossenberg, Bart; Wieringa, Jan J; Kraaijeveld, Ken; Stielow, Benjamin; Geml, József; Richardson, James E; Bakker, Freek T

    2013-01-01

    Unlocking the vast genomic diversity stored in natural history collections would create unprecedented opportunities for genome-scale evolutionary, phylogenetic, domestication and population genomic studies. Many researchers have been discouraged from using historical specimens in molecular studies because of both generally limited success of DNA extraction and the challenges associated with PCR-amplifying highly degraded DNA. In today's next-generation sequencing (NGS) world, opportunities and prospects for historical DNA have changed dramatically, as most NGS methods are actually designed for taking short fragmented DNA molecules as templates. Here we show that using a standard multiplex and paired-end Illumina sequencing approach, genome-scale sequence data can be generated reliably from dry-preserved plant, fungal and insect specimens collected up to 115 years ago, and with minimal destructive sampling. Using a reference-based assembly approach, we were able to produce the entire nuclear genome of a 43-year-old Arabidopsis thaliana (Brassicaceae) herbarium specimen with high and uniform sequence coverage. Nuclear genome sequences of three fungal specimens of 22-82 years of age (Agaricus bisporus, Laccaria bicolor, Pleurotus ostreatus) were generated with 81.4-97.9% exome coverage. Complete organellar genome sequences were assembled for all specimens. Using de novo assembly we retrieved between 16.2-71.0% of coding sequence regions, and hence remain somewhat cautious about prospects for de novo genome assembly from historical specimens. Non-target sequence contaminations were observed in 2 of our insect museum specimens. We anticipate that future museum genomics projects will perhaps not generate entire genome sequences in all cases (our specimens contained relatively small and low-complexity genomes), but at least generating vital comparative genomic data for testing (phylo)genetic, demographic and genetic hypotheses, that become increasingly more horizontal

  14. cDNA Microarray Analysis of Serially Sampled Cervical Cancer Specimens From Patients Treated With Thermochemoradiotherapy

    International Nuclear Information System (INIS)

    Borkamo, Erling Dahl; Schem, Baard-Christian; Fluge, Oystein; Bruland, Ove; Dahl, Olav; Mella, Olav

    2009-01-01

    Purpose: To elucidate changes in gene expression after treatment with regional thermochemoradiotherapy in locally advanced squamous cell cervical cancer. Methods and Materials: Tru-Cut biopsy specimens were serially collected from 16 patients. Microarray gene expression levels before and 24 h after the first and second trimodality treatment sessions were compared. Pathway and network analyses were conducted by use of Ingenuity Pathways Analysis (IPA; Ingenuity Systems, Redwood City, CA). Single gene expressions were analyzed by quantitative real-time reverse transcription-polymerase chain reaction. Results: We detected 53 annotated genes that were differentially expressed after trimodality treatment. Central in the three top networks detected by IPA were interferon alfa, interferon beta, and interferon gamma receptor; nuclear factor κB; and tumor necrosis factor, respectively. These genes encode proteins that are important in regulation cell signaling, proliferation, gene expression, and immune stimulation. Biological processes over-represented among the 53 genes were fibrosis, tumorigenesis, and immune response. Conclusions: Microarrays showed minor changes in gene expression after thermochemoradiotherapy in locally advanced cervical cancer. We detected 53 differentially expressed genes, mainly involved in fibrosis, tumorigenesis, and immune response. A limitation with the use of serial biopsy specimens was low quality of ribonucleic acid from tumors that respond to highly effective therapy. Another 'key limitation' is timing of the post-treatment biopsy, because 24 h may be too late to adequately assess the impact of hyperthermia on gene expression.

  15. A study on preparation of cross sectional anatomy specimen of cadaver

    International Nuclear Information System (INIS)

    Im, C. K.; Choi, B. I.; Park, J. H.; Chang, K. H.; Yeon, K. M.; Han, M. C.; Kim, C. W.

    1984-01-01

    With the advent of cross sectional image of CT, ultrasound and magnetic resonance, the need for knowledge of cross sectional anatomy is stranger than ever. To meet this need, preparation of cross sectional anatomy specimen using cadaver is indispensable, not only because it tis the real cut surface anatomy but also because overt limitations of radiographic image in both contrast and special resolution. Authors prepared cross sectional anatomy specimen using a male cadaver, comprising photographs and slides of the 60 cross cut slices from the head to the pelvis. After photography, each slices was embedded using transparent resin allowing permanent preservation of specimen without altering its original architecture. Author's unique method of preparation is presented and 4 representative specimens are illustrated comparing cadaver's CT image, cross cut surface photography, and photography of resin embedded slice of the same cut surface.

  16. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    International Nuclear Information System (INIS)

    Naqvi, A.A.; Garwan, M.A.; Maslehuddin, M.; Nagadi, M.M.; Al-Amoudi, O.S.B.; Raashid, M.

    2010-01-01

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the γ-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring γ-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  17. Response of a PGNAA setup for pozzolan-based cement concrete specimens

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)], E-mail: aanaqvi@kfupm.edu.sa; Garwan, M.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Maslehuddin, M. [Center for Engineering Research, Research Institute, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Raashid, M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2010-04-15

    Pozzolanic materials are added to Portland cement concrete to increase its durability, particularly corrosion-resistance. In this study the elemental composition of a pozzolanic cement concrete was measured non-destructively utilizing an accelerator-based Prompt Gamma Ray Neutron Activation Analysis (PGNAA) setup. The optimum size of the pozzolanic cement concrete specimen was obtained through Monte Carlo simulations. The simulation results were experimentally verified through the {gamma}-ray yield measurement from the pozzolanic cement concrete specimens as a function of their radii. The concentration of the pozzolanic material in the cement concrete specimens was evaluated by measuring {gamma}-ray yield for calcium and iron from pozzolanic cement concrete specimens containing 5-80 wt% pozzolan. A good agreement was noted between the experimental values and the Monte Carlo simulation results, indicating an excellent response of the KFUPM accelerator-based PGNAA setup for pozzolan based concrete.

  18. Relationship between strain and central deflection in small punch creep specimens

    International Nuclear Information System (INIS)

    Yang Zhen; Wang Zhiwen

    2003-01-01

    Acquiring information about creep strain directly from small punch creep tests is difficult because the deformation behaviour of the small punch specimen is complicated. A routine is suggested in the present paper to treat this problem indirectly. Based on a finite element analysis, it is proposed that the relationship of central deflection δ to central creep strain ε c of a specimen subjected to creep can be represented approximately by the relationship of central deflection δ to central (elastic-plastic) strain ε of a specimen not subjected to creep. With this hypothesis, the δ∼ε c relation of the small punch creep specimen is obtained by resorting to a rigid-plastic membrane stretch forming model. Finally, small punch creep test results are used to evaluate creep strain and creep strain rate by taking advantage of this δ∼ε c relation

  19. Colorectal carcinoma: Ex vivo evaluation using 3-T high-spatial-resolution quantitative T2 mapping and its correlation with histopathologic findings.

    Science.gov (United States)

    Yamada, Ichiro; Yoshino, Norio; Hikishima, Keigo; Miyasaka, Naoyuki; Yamauchi, Shinichi; Uetake, Hiroyuki; Yasuno, Masamichi; Saida, Yukihisa; Tateishi, Ukihide; Kobayashi, Daisuke; Eishi, Yoshinobu

    2017-05-01

    In this study, we aimed to evaluate the feasibility of determining the mural invasion depths of colorectal carcinomas using high-spatial-resolution (HSR) quantitative T2 mapping on a 3-T magnetic resonance (MR) scanner. Twenty colorectal specimens containing adenocarcinomas were imaged on a 3-T MR system equipped with a 4-channel phased-array surface coil. HSR quantitative T2 maps were acquired using a spin-echo sequence with a repetition time/echo time of 7650/22.6-361.6ms (16 echoes), 87×43.5-mm field of view, 2-mm section thickness, 448×224 matrix, and average of 1. HSR fast-spin-echo T2-weighted images were also acquired. Differences between the T2 values (ms) of the tumor tissue, colorectal wall layers, and fibrosis were measured, and the MR images and histopathologic findings were compared. In all specimens (20/20, 100%), the HSR quantitative T2 maps clearly depicted an 8-layer normal colorectal wall in which the T2 values of each layer differed from those of the adjacent layer(s) (PT2 maps and histopathologic data yielded the same findings regarding the tumor invasion depth. Our results indicate that 3-T HSR quantitative T2 mapping is useful for distinguishing colorectal wall layers and differentiating tumor and fibrotic tissues. Accordingly, this technique could be used to determine mural invasion by colorectal carcinomas with a high level of accuracy. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Quantitative Collection and Enzymatic Activity of Glucose Oxidase Nanotubes Fabricated by Templated Layer-by-Layer Assembly.

    Science.gov (United States)

    Zhang, Shouwei; Demoustier-Champagne, Sophie; Jonas, Alain M

    2015-08-10

    We report on the fabrication of enzyme nanotubes in nanoporous polycarbonate membranes via the layer-by-layer (LbL) alternate assembly of polyethylenimine (PEI) and glucose oxidase (GOX), followed by dissolution of the sacrificial template in CH2Cl2, collection, and final dispersion in water. An adjuvant-assisted filtration methodology is exploited to extract quantitatively the nanotubes without loss of activity and morphology. Different water-soluble CH2Cl2-insoluble adjuvants are tested for maximal enzyme activity and nanotube stability; whereas NaCl disrupts the tubes by screening electrostatic interactions, the high osmotic pressure created by fructose also contributes to loosening the nanotubular structures. These issues are solved when using neutral, high molar mass dextran. The enzymatic activity of intact free nanotubes in water is then quantitatively compared to membrane-embedded nanotubes, showing that the liberated nanotubes have a higher catalytic activity in proportion to their larger exposed surface. Our study thus discloses a robust and general methodology for the fabrication and quantitative collection of enzymatic nanotubes and shows that LbL assembly provides access to efficient enzyme carriers for use as catalytic swarming agents.