WorldWideScience

Sample records for quantitaive real-time pcr

  1. Validation of RNAi by real time PCR

    DEFF Research Database (Denmark)

    Josefsen, Knud; Lee, Ying Chiu

    2011-01-01

    Real time PCR is the analytic tool of choice for quantification of gene expression, while RNAi is concerned with downregulation of gene expression. Together, they constitute a powerful approach in any loss of function studies of selective genes. We illustrate here the use of real time PCR to veri...

  2. Real time PCR. Application in dengue studies

    Directory of Open Access Journals (Sweden)

    Jeanette Prada-Arismendy

    2011-06-01

    Full Text Available PCR (polymerase chain reaction is a routinely used tool in every diagnostic and research laboratory. This technique has been used in detection of mutations and pathogens, forensic investigation, and even is the base tool for human genome sequencing. A modification of PCR technique, real time PCR, allows the quantification of nucleic acids with higher sensibility, specificity and reproducibility. This article is intended to clarify the foundations of real-time PCR, using an application model for virology. In the actual work, it was quantified the viral load of dengue virus serotype 2 produced from infected murine macrophages; the obtained results in this work established that murine strain BALB/c presents a greater susceptibility to dengue virus infection, which establishes BALB/c murine strain as a best model of study for investigation of dengue virus infection physiopathology.

  3. The Power of Real-Time PCR

    Science.gov (United States)

    Valasek, Mark A.; Repa, Joyce J.

    2005-01-01

    In recent years, real-time polymerase chain reaction (PCR) has emerged as a robust and widely used methodology for biological investigation because it can detect and quantify very small amounts of specific nucleic acid sequences. As a research tool, a major application of this technology is the rapid and accurate assessment of changes in gene…

  4. Real-time PCR in microfluidic devices

    Science.gov (United States)

    Becker, Holger; Hlawatsch, Nadine; Klemm, Richard; Moche, Christian; Hansen-Hagge, Thomas; Gärtner, Claudia

    2014-03-01

    A central method in a standard biochemical laboratory is represented by the polymerase chain reaction (PCR), therefore many attempts have been performed so far to implement this technique in lab-on-a-chip (LOC) devices. PCR is an ideal candidate for miniaturization because of a reduction of assay time and decreased costs for expensive bio-chemicals. In case of the "classical" PCR, detection is done by identification of DNA fragments electrophoretically separated in agarose gels. This method is meanwhile frequently replaced by the so-called Real-Time-PCR because here the exponential increase of amplificates can be observed directly by measurement of DNA interacting fluorescent dyes. Two main methods for on-chip PCRs are available: traditional "batch" PCR in chambers on a chip using thermal cycling, requiring about 30 minutes for a typical PCR protocol and continuous-flow PCR, where the liquid is guided over stationary temperature zones. In the latter case, the PCR protocol can be as fast as 5 minutes. In the presented work, a proof of concept is demonstrated for a real-time-detection of PCR products in microfluidic systems.

  5. Real Time PCR: Principles and Application

    Directory of Open Access Journals (Sweden)

    Safie Amini

    2005-09-01

    Full Text Available The polymerase chain reaction (PCR has been used as the new golden standard for detecting a wide variety of templates across a range of scientific specialties and also as an essential tool in research laboratories. PCR has completely revolutionized the detection of RNA and DNA viruses(1. Real Time vs. Traditional PCRReal time chemistry allows the detection of PCR amplification during the early phase of the reaction. Measuring the kinetic of the reaction in the early phase of PCR provides a distinct advantage over traditional PCR detection. Traditional methods use agarose gel electrophoresis for detection of PCR amplification at the final phase or end point. End point detection is really time consuming; it takes several hours to have the result. On the other hand, results are based on size discrimination. Also, the result of end point is variable from sample to sample. While gels may not resolve this variability in yield, real time PCR is sensitive enough to detect this change.Some problems with end point detection are: poor precision, low sensitivity, short dynamic range (<2 log, low resolution, non-automated procedure, size-based discrimination only, and post PCR processing (carry-over contamination and results are not expressed as numbers(2.Detection of PCR Products in Real-timeReal-time PCR and RT-PCR allow accurate quantification of starting amounts of DNA, cDNA, and RNA targets. Fluorescence is measured during each cycle, which greatly increases the dynamic range of the reaction since the amount offluorescence is proportional to the amount of PCR product. PCR products can be detected using either fluorescent dyes that bind to double-stranded DNA or fluorescently labeled sequence-specific probes(3.SYBR Green ISYBR® Green I binds all double-stranded DNA molecules, emitting a fluorescent signal of a defined wavelength on binding. The excitation and emission maxima of SYBR Green I are at 494 nm and 521 nm, respectively, and are compatible for

  6. Real-Time PCR for Universal Phytoplasma Detection and Quantification

    DEFF Research Database (Denmark)

    Christensen, Nynne Meyn; Nyskjold, Henriette; Nicolaisen, Mogens

    2013-01-01

    Currently, the most efficient detection and precise quantification of phytoplasmas is by real-time PCR. Compared to nested PCR, this method is less sensitive to contamination and is less work intensive. Therefore, a universal real-time PCR method will be valuable in screening programs and in other...

  7. Real-time PCR: Advanced technologies and applications

    Science.gov (United States)

    This book brings together contributions from 20 experts in the field of PCR, providing a broad perspective of the applications of quantitative real-time PCR (qPCR). The editors state in the preface that the aim is to provide detailed insight into underlying principles and methods of qPCR to provide ...

  8. Real-time PCR in Food Science: PCR Diagnostics.

    Science.gov (United States)

    Rodriguez-Lazaro, David; Cook, Nigel; Hernandez, Marta

    2013-01-01

    A principal consumer demand is a guarantee of the safety and quality of food. The presence of foodborne pathogens and their potential hazard, the use of genetically modified organisms (GMOs) in food production, and the correct labelling in foods suitable for vegetarians are among the subjects where society demands total transparency. The application of controls within the quality assessment programmes of the food industry is a way to satisfy these demands, and is necessary to ensure efficient analytical methodologies are possessed and correctly applied by the Food Sector. The use of real-time PCR has become a promising alternative approach in food diagnostics. It possesses a number of advantages over conventional culturing approaches, including rapidity, excellent analytical sensitivity and selectivity, and potential for quantification. However, the use of expensive equipment and reagents, the need for qualified personnel, and the lack of standardized protocols are impairing its practical implementation for food monitoring and control.

  9. Comparison of conventional culture and real-time quantitative PCR ...

    African Journals Online (AJOL)

    2009-10-28

    Oct 28, 2009 ... Results of real-time PCR were compared to con- ventional analysis .... water bath (Selecta 40W power, 40 kHz ultrasound fre- quency). ..... mental distributions of Legionella strains in France are different. J. clin. Microbiol.

  10. Real-time PCR and PCR-tandem Mass Spectrometry for Biodetection

    Science.gov (United States)

    2005-10-01

    Real - time PCR and PCR- tandem mass spectrometry for biodetection Alvin Fox, University of South Carolina, School of Medicine Report Documentation...TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Real - time PCR and PCRtandem mass spectrometry for biodetection 5a. CONTRACT NUMBER 5b...interspace region Bacillus subtilis W23 standard Blank Barn dust House dust Cycle Real - time PCR (16s rRNA) - environmental samples Real - time

  11. Overcoming inhibition in real-time diagnostic PCR.

    Science.gov (United States)

    Hedman, Johannes; Rådström, Peter

    2013-01-01

    PCR is an important and powerful tool in several fields, including clinical diagnostics, food analysis, and forensic analysis. In theory, PCR enables the detection of one single cell or DNA molecule. However, the presence of PCR inhibitors in the sample affects the amplification efficiency of PCR, thus lowering the detection limit, as well as the precision of sequence-specific nucleic acid quantification in real-time PCR. In order to overcome the problems caused by PCR inhibitors, all the steps leading up to DNA amplification must be optimized for the sample type in question. Sampling and sample treatment are key steps, but most of the methods currently in use were developed for conventional diagnostic methods and not for PCR. Therefore, there is a need for fast, simple, and robust sample preparation methods that take advantage of the accuracy of PCR. In addition, the thermostable DNA polymerases and buffer systems used in PCR are affected differently by inhibitors. During recent years, real-time PCR has developed considerably and is now widely used as a diagnostic tool. This technique has greatly improved the degree of automation and reduced the analysis time, but has also introduced a new set of PCR inhibitors, namely those affecting the fluorescence signal. The purpose of this chapter is to view the complexity of PCR inhibition from different angles, presenting both molecular explanations and practical ways of dealing with the problem. Although diagnostic PCR brings together scientists from different diagnostic fields, end-users have not fully exploited the potential of learning from each other. Here, we have collected knowledge from archeological analysis, clinical diagnostics, environmental analysis, food analysis, and forensic analysis. The concept of integrating sampling, sample treatment, and the chemistry of PCR, i.e., pre-PCR processing, will be addressed as a general approach to overcoming real-time PCR inhibition and producing samples optimal for PCR

  12. Monitoring gene expression: quantitative real-time rt-PCR.

    Science.gov (United States)

    Wagner, Elke M

    2013-01-01

    Two-step quantitative real-time RT-PCR (RT-qPCR), also known as real-time RT-PCR, kinetic RT-PCR, or quantitative fluorescent RT-PCR, has become the method of choice for gene expression analysis during the last few years. It is a fast and convenient PCR method that combines traditional RT-PCR with the phenomenon of fluorescence resonance energy transfer (FRET) using fluorogenic primers. The detection of changes in fluorescence intensity during the reaction enables the user to follow the PCR reaction in real time.RT-qPCR comprises several steps: (1) RNA is isolated from target tissue/cells; (2) mRNA is reverse-transcribed to cDNA; (3) modified gene-specific PCR primers are used to amplify a segment of the cDNA of interest, following the reaction in real time; and (4) the initial concentration of the selected transcript in a specific tissue or cell type is calculated from the exponential phase of the reaction. Relative quantification or absolute quantification compared to standards that are run in parallel can be performed.This chapter describes the entire procedure from isolation of total RNA from liver and fatty tissues/cells to the use of RT-qPCR to study gene expression in these tissues. We perform relative quantification of transcripts to calculate the fold-difference of a certain mRNA level between different samples. In addition, tips for choosing primers and performing analyses are provided to help the beginner in understanding the technique.

  13. Real-time PCR in Food Science: Introduction.

    Science.gov (United States)

    Rodriguez-Lazaro, David; Hernandez, Marta

    2013-01-01

    Food safety and quality control programmes are increasingly applied throughout the production food chain in order to guarantee added value products as well as to minimize the risk of infection for the consumer. The development of real-time PCR has represented one of the most significant advances in food diagnostics as it provides rapid, reliable and quantitative results. These aspects become increasingly important for the agricultural and food industry. Different strategies for real-time PCR diagnostics have been developed including unspecific detection independent of the target sequence using fluorescent dyes such as SYBR Green, or by sequence-specific fluorescent oligonucleotide probes such as TaqMan probes or molecular beacons.

  14. Shape based kinetic outlier detection in real-time PCR

    Directory of Open Access Journals (Sweden)

    D'Atri Mario

    2010-04-01

    Full Text Available Abstract Background Real-time PCR has recently become the technique of choice for absolute and relative nucleic acid quantification. The gold standard quantification method in real-time PCR assumes that the compared samples have similar PCR efficiency. However, many factors present in biological samples affect PCR kinetic, confounding quantification analysis. In this work we propose a new strategy to detect outlier samples, called SOD. Results Richards function was fitted on fluorescence readings to parameterize the amplification curves. There was not a significant correlation between calculated amplification parameters (plateau, slope and y-coordinate of the inflection point and the Log of input DNA demonstrating that this approach can be used to achieve a "fingerprint" for each amplification curve. To identify the outlier runs, the calculated parameters of each unknown sample were compared to those of the standard samples. When a significant underestimation of starting DNA molecules was found, due to the presence of biological inhibitors such as tannic acid, IgG or quercitin, SOD efficiently marked these amplification profiles as outliers. SOD was subsequently compared with KOD, the current approach based on PCR efficiency estimation. The data obtained showed that SOD was more sensitive than KOD, whereas SOD and KOD were equally specific. Conclusion Our results demonstrated, for the first time, that outlier detection can be based on amplification shape instead of PCR efficiency. SOD represents an improvement in real-time PCR analysis because it decreases the variance of data thus increasing the reliability of quantification.

  15. Nanodroplet real-time PCR system with laser assisted heating.

    Science.gov (United States)

    Kim, Hanyoup; Dixit, Sanhita; Green, Christopher J; Faris, Gregory W

    2009-01-01

    We report the successful application of low-power (approximately 30 mW) laser radiation as an optical heating source for high-speed real-time polymerase chain reaction (PCR) amplification of DNA in nanoliter droplets dispersed in an oil phase. Light provides the heating, temperature measurement, and Taqman real-time readout in nanoliter droplets on a disposable plastic substrate. A selective heating scheme using an infrared laser appears ideal for driving PCR because it heats only the droplet, not the oil or plastic substrate, providing fast heating and completing the 40 cycles of PCR in 370 seconds. No microheaters or microfluidic circuitry were deposited on the substrate, and PCR was performed in one droplet without affecting neighboring droplets. The assay performance was quantitative and its amplification efficiency was comparable to that of a commercial instrument.

  16. Introducing Undergraduate Students to Real-Time PCR

    Science.gov (United States)

    Hancock, Dale; Funnell, Alister; Jack, Briony; Johnston, Jill

    2010-01-01

    An experiment is conducted, which in four 3 h laboratory sessions, introduces third year undergraduate Biochemistry students to the technique of real-time PCR in a biological context. The model used is a murine erythroleukemia cell line (MEL cells). These continuously cycling, immature red blood cells, arrested at an early stage in erythropoiesis,…

  17. Real-Time PCR Quantification of Methanobrevibacter oralis in Periodontitis

    OpenAIRE

    Bringuier, Amélie; Khelaifia, Saber; Richet, Hervé; Aboudharam, Gérard; Drancourt, Michel

    2013-01-01

    A real-time PCR assay developed to quantify Methanobrevibacter oralis indicated that its inoculum significantly correlated with periodontitis severity (P = 0.003), despite a nonsignificant difference in prevalence between controls (3/10) and patients (12/22) (P = 0.2, Fisher test). The M. oralis load can be used as a biomarker for periodontitis.

  18. Introducing Undergraduate Students to Real-Time PCR

    Science.gov (United States)

    Hancock, Dale; Funnell, Alister; Jack, Briony; Johnston, Jill

    2010-01-01

    An experiment is conducted, which in four 3 h laboratory sessions, introduces third year undergraduate Biochemistry students to the technique of real-time PCR in a biological context. The model used is a murine erythroleukemia cell line (MEL cells). These continuously cycling, immature red blood cells, arrested at an early stage in erythropoiesis,…

  19. Real-time PCR for Strongyloides stercoralis-associated meningitis.

    Science.gov (United States)

    Nadir, Eyal; Grossman, Tamar; Ciobotaro, Pnina; Attali, Malka; Barkan, Daniel; Bardenstein, Rita; Zimhony, Oren

    2016-03-01

    Four immunocompromised patients, immigrants from Ethiopia, presented with diverse clinical manifestations of meningitis associated with Strongyloides stercoralis dissemination as determined by identification of intestinal larvae. The cerebrospinal fluid of 3 patients was tested by a validated (for stool) real-time PCR for S. stercoralis and was found positive, establishing this association.

  20. Mathematical analysis of the real time array PCR (RTA PCR) process

    NARCIS (Netherlands)

    Dijksman, Johan Frederik; Pierik, A.

    2012-01-01

    Real time array PCR (RTA PCR) is a recently developed biochemical technique that measures amplification curves (like with quantitative real time Polymerase Chain Reaction (qRT PCR)) of a multitude of different templates in a sample. It combines two different methods in order to profit from the

  1. Mathematical analysis of the real time array PCR (RTA PCR) process

    NARCIS (Netherlands)

    Dijksman, J.F.; Pierik, A.

    2012-01-01

    Real time array PCR (RTA PCR) is a recently developed biochemical technique that measures amplification curves (like with quantitative real time Polymerase Chain Reaction (qRT PCR)) of a multitude of different templates in a sample. It combines two different methods in order to profit from the adva

  2. Employing Real Time PCR for the Diagnosis of Huntington Disease

    Directory of Open Access Journals (Sweden)

    Frouzandeh Mahjoubi

    2013-07-01

    Full Text Available Background: Huntington disease (HD is a dominantly inherited, neurodegenerative disease characterized by choreiform movement disturbances and dementia. The onset age of this disease is varied but usually is between the ages 40-50. Huntington's disease is caused by a triplet-repeat expansion in the IT15 gene (also known as huntingtin or HD which is located on chromosome 4p3.1. Since many clinical picture of HD are indistinguishable from other distinct genetic disorders molecular test such as PCR is the only way to confirm the disease. The aim of this study was to introduce a new and fast technique for the diagnosis of Huntington disease.Materials and Methods: Blood specimens were collected from individuals suspected for Huntington disease and also people with no symptoms and family history of this disease. DNAs were extracted according to standard protocol. Using conventional PCR, patient positive for Huntington disease were diagnosed. Then employing real time PCR on the basis of difference between melting temperature (Tm a new and fast diagnostic method was introduced.Results: Among 29 patients suspected to be HD only 8 HD patients were confirmed using PCR and real time PCR. The numbers of CAG repeat were between 42-50 and melting temperatures were between 89-92.Conclusion: The concept of using melting temperature in real time PCR protocol presented in here could be employed for the rapid diagnosis of the diseases caused by the increased in triple repeat sequences. It is fast, robust and has the potential use for the prenatal diagnosis.

  3. Result Variation and Efficiency Kinetics in Real-Time PCR

    Directory of Open Access Journals (Sweden)

    Reza Shahsiah

    2010-10-01

    Full Text Available Fluorescent monitoring of DNA amplification is the basis of real-time PCR. Absolute quantification can be achieved using a standard curve method. The standard curve is constructed by amplifying known amounts of standards under identical conditions to that of the samples.The objective of the current study is to propose a mathematical model to assess the acceptability of PCR resulys.Four commercial standards for HCV-RNA (hepatitis C virus RNA along with 6 patient samples were measured by real-time PCR, using two different RT-PCR reagents. The standard deviation of regression (Sy,x was calculated for each group of standard and compared by F-Test. The efficiency kinetics was computed by logistic regression, c2 goodness of fit test was preformed to assess the appropriateness of the efficiency curves.Calculated efficiencies were not significantly different from the value predicted by logistic regression model. Reactions with more variation showed less stable efficiency curves, with wider range of amplification efficiencies.Amplification efficiency kinetics can be computed by fitting a logistic regression curve to the gathered fluorescent data of each reaction. This model can be employed to assess the acceptability of PCR results calculated by standard curve method.

  4. Application of Reverse Transcription-PCR and Real-Time PCR in Nanotoxicity Research

    Science.gov (United States)

    Mo, Yiqun; Wan, Rong; Zhang, Qunwei

    2016-01-01

    Reverse transcription-polymerase chain reaction (RT-PCR) is a relatively simple and inexpensive technique to determine the expression level of target genes and is widely used in biomedical science research including nanotoxicology studies for semiquantitative analysis. Real-time PCR allows for the detection of PCR amplification in the exponential growth phase of the reaction and is much more quantitative than traditional RT-PCR. Although a number of kits and reagents for RT-PCR and real-time PCR are commercially available, the basic principles are the same. Here, we describe the procedures for total RNA isolation by using TRI Reagent, for reverse transcription (RT) by M-MLV reverse transcriptase, and for PCR by GoTaq® DNA Polymerase. And real-time PCR will be performed on an iQ5 multicolor real-time PCR detection system by using iQ™ SYBR Green Supermix. PMID:22975959

  5. Real-Time PCR (RT-PCR) Assays for Burkholderia mallei and B. pseudomallei

    Science.gov (United States)

    2005-10-01

    1 Real - time PCR (RT-PCR) Assays for Burkholderia mallei and B. pseudomallei Vipin K. Rastogi1, Tu-chen Cheng1, Lisa Collins1 and Jennifer Bagley2 1...A 3. DATES COVERED - 4. TITLE AND SUBTITLE Real - time PCR (RT-PCR) Assays for Burkholderia mallei and B.pseudomallei 5a. CONTRACT NUMBER 5b...risk. There is currently no real - time PCR assay for detection of both of these pathogens. Primers and probes corresponding to specific genomic regions

  6. Mathematical analysis of the real time array PCR (RTA PCR) process

    NARCIS (Netherlands)

    Dijksman J.F.; Pierik, A.

    2012-01-01

    Real Time Array PCR is a recently developed biochemical technique that measures amplification curves (like quantitative real time Polymerase Chain Reaction (qPCR)) of a multitude of different templates ina sample. It combines two different techniques to profit from theadvantages of both techniques,

  7. Mathematical analysis of the real time array PCR (RTA PCR) process

    NARCIS (Netherlands)

    Dijksman J.F.; Pierik, A.

    2012-01-01

    Real Time Array PCR is a recently developed biochemical technique that measures amplification curves (like quantitative real time Polymerase Chain Reaction (qPCR)) of a multitude of different templates ina sample. It combines two different techniques to profit from theadvantages of both techniques,

  8. Real-Time PCR (qPCR) Primer Design Using Free Online Software

    Science.gov (United States)

    Thornton, Brenda; Basu, Chhandak

    2011-01-01

    Real-time PCR (quantitative PCR or qPCR) has become the preferred method for validating results obtained from assays which measure gene expression profiles. The process uses reverse transcription polymerase chain reaction (RT-PCR), coupled with fluorescent chemistry, to measure variations in transcriptome levels between samples. The four most…

  9. Real-Time PCR (qPCR) Primer Design Using Free Online Software

    Science.gov (United States)

    Thornton, Brenda; Basu, Chhandak

    2011-01-01

    Real-time PCR (quantitative PCR or qPCR) has become the preferred method for validating results obtained from assays which measure gene expression profiles. The process uses reverse transcription polymerase chain reaction (RT-PCR), coupled with fluorescent chemistry, to measure variations in transcriptome levels between samples. The four most…

  10. Electrochemistry-based real-time PCR on a microchip.

    Science.gov (United States)

    Yeung, Stephen S W; Lee, Thomas M H; Hsing, I-Ming

    2008-01-15

    The development of handheld instruments for point-of-care DNA analysis can potentially contribute to the medical diagnostics and environmental monitoring for decentralized applications. In this work, we demonstrate the implementation of a recently developed electrochemical real-time polymerase chain reaction (ERT-PCR) technique on a silicon-glass microchip for simultaneous DNA amplification and detection. This on-chip ERT-PCR process requires the extension of an oligonucleotide in both solution and at solid phases and intermittent electrochemical signal measurement in the presence of all the PCR reagents. Several important parameters, related to the surface passivation and electrochemical scanning of working electrodes, were investigated. It was found that the ERT-PCR's onset thermal cycle ( approximately 3-5), where the analytical signal begins to be distinguishable from the background, is much lower than that of the fluorescence-based counterparts for high template DNA situations (3 x 10(6) copies/microL). By carefully controlling the concentrations of the immobilized probe and the enzyme polymerase, improvements have been made in obtaining a meaningful electrochemical signal using a lower initial template concentration. This ERT-PCR technique on a microchip platform holds significant promise for rapid DNA detection for point-of-care testing applications.

  11. Cytokine mRNA quantification by real-time PCR.

    Science.gov (United States)

    Stordeur, Patrick; Poulin, Lionel F; Craciun, Ligia; Zhou, Ling; Schandené, Liliane; de Lavareille, Aurore; Goriely, Stanislas; Goldman, Michel

    2002-01-01

    Real-time PCR represents a new methodology that accurately quantifies nucleic acids. This has been made possible by the use of fluorogenic probes, which are presented in two forms, namely hydrolysis probes (also called TaqMan probes) and hybridisation probes. We decided to apply this methodology to cytokine mRNA quantification and this led us to the development of a protocol that provides an easy way to develop and perform rapidly real-time PCR on a Lightcycler instrument. It was made possible by the use of freely available software that permits a choice of both the hydrolysis probe and the primers. We firstly demonstrated that the reproducibility of the method using hydrolysis probes compares favourably with that obtained with hybridisation probes. We then applied this technique to determine the kinetics of IL-1ra, IL-1beta, IL-5, IL-13, TNF-alpha and IFN-gamma induction upon stimulation of human peripheral blood mononuclear cells (PBMC) by phytohaemagglutinin (PHA). Finally, the method was also used successfully to demonstrate that IFN-alpha induces IL-10 mRNA accumulation in human monocytes.

  12. Multiplex real-time PCR assay for Legionella species.

    Science.gov (United States)

    Kim, Seung Min; Jeong, Yoojung; Sohn, Jang Wook; Kim, Min Ja

    2015-12-01

    Legionella pneumophila serogroup 1 (sg1) accounts for the majority of infections in humans, but other Legionella species are also associated with human disease. In this study, a new SYBR Green I-based multiplex real-time PCR assay in a single reaction was developed to allow the rapid detection and differentiation of Legionella species by targeting specific gene sequences. Candidate target genes were selected, and primer sets were designed by referring to comparative genomic hybridization data of Legionella species. The Legionella species-specific groES primer set successfully detected all 30 Legionella strains tested. The xcpX and rfbA primers specifically detected L. pneumophila sg1-15 and L. pneumophila sg1, respectively. In addition, this assay was validated by testing clinical samples and isolates. In conclusion, this novel multiplex real-time PCR assay might be a useful diagnostic tool for the rapid detection and differentiation of Legionella species in both clinical and epidemiological studies.

  13. Genus identification of toxic plant by real-time PCR.

    Science.gov (United States)

    Matsuyama, Shuji; Nishi, Katsuji

    2011-03-01

    Some plants have toxicities that are dangerous for humans. In the case of poisoning by toxic plants, a rapid and easy screening test is required for accurate medical treatment or forensic investigation. In this study, we designed specific primer pairs for identification of toxic plants, such as subgenus Aconitum, genus Ricinus, genus Illicium, and genus Scopolia, by internal transcribed spacer sequences of nuclear ribosomal DNA. Allied species of target plants, foods, and human DNA were not detected, but each primer pair provided a specific PCR product from the target plant using real-time PCR. This method can detect the subgenus Aconitum, genus Ricinus, and genus Scopolia with template DNA of 10 pg, respectively, and genus Illicium with 1 pg. Furthermore, each primer pair provided the exact PCR product from digested target plants in artificial gastric fluid. When a trace unknown plant sample in forensic investigation is collected from stomach contents, this PCR assay may be useful for screening toxic plants.

  14. Diagnosis of aerobic vaginitis by quantitative real-time PCR.

    Science.gov (United States)

    Rumyantseva, T A; Bellen, G; Savochkina, Y A; Guschin, A E; Donders, G G G

    2016-07-01

    To evaluate a real-time PCR-based technique to quantify bacteria associated with aerobic vaginitis (AV) as a potential test. Vaginal samples from 100 women were tested by wet-mount microscopy, gram stain and quantitative real-time PCR targeting Enterobacteriacea, Staphylococcus spp., Streptococcus spp., Enterococcus spp., Escherichia coli, Streptococcus agalactiae, S. aureus; Lactobacillus spp. AV diagnosis obtained by wet-mount microscopy was used as reference. Some level of AV was diagnosed in 23 (23.7 %) cases. Various concentrations of Enterobacteriacea, Staphylococcus spp., Streptococcus spp. were detected an all patients. Enterococcus spp. were detected in 76 (78.3 %) cases. Summarized concentrations of aerobes were tenfold higher in AV-positive compared to AV-negative cases [7.30lg vs 6.06lg (p = 0.02)]. Concentrations of aerobes in severe, moderate and light AV cases did not vary significantly (p = 0.14). Concentration of lactobacilli was 1000-fold lower in AV-positive cases compared to normal cases (5.3lg vs 8.3lg, p < 0.0001). Streptococcus spp. dominated in the majority of AV-positive cases [19/22 (86.4 %) samples]. The relation of high loads of aerobes to the low numbers of Lactobacilli are a reliable marker for the presence of AV and could substitute microscopy as a test. PCR may be a good standardized substitution for AV diagnosis in settings where well-trained microscopists are lacking.

  15. Using Real-time PCR for Identification of Paenibacillus larvae

    Directory of Open Access Journals (Sweden)

    Vladimíra Kňazovická

    2011-05-01

    Full Text Available The aim of the study was identification of Paenibacillus larvae that causes American foulbrood disease (AFB in colony of bees (Apis mellifera. Bacterial isolates originated from honey samples, because presence of P. larvae in honey is treated as early diagnostic of AFB. Intense proteolytic activity and no catalase activity are typical for Gram positive rod-shaped bacteria P. larvae. We diluted honey (1:2, heated at 80 °C for 10 min and inoculated on semiselective medium MYPGP agar with nalidixic acid. Plates were cultivated at 37 °C for 48 – 72 h under the aerobic conditions. Selected colonies were transferred on MYT agar and cultivated 24 h. We analysed 30 honey samples and found 27 bacterial isolates. All isolates were Gram positive and mainly rod-shaped. No catalase activity was documented for 6 from 27 isolates. Identification was finished by real-time PCR to detect the 16S rRNA gene of Paenibacillus larvae with real-time cycler Rotor-Gene 6000. As DNA template we used genomic DNA isolated with commercial kit and DNA lysate obtaining by boiled cells. We used 2 strains of P. larvae from CCM (Czech Collection of Microorganisms as positive control. The reliable method of detection P. larvae has important rule for beekeeping.

  16. Real-Time PCR Identification of Unique Bacillus anthracis Sequences.

    Science.gov (United States)

    Cieślik, P; Knap, J; Kolodziej, M; Mirski, T; Joniec, J; Graniak, G; Zakowska, D; Winnicka, I; Bielawska-Drózd, A

    2015-01-01

    Bacillus anthracis is a spore-forming, Gram-positive microorganism. It is a causative agent of anthrax, a highly infectious disease. It belongs to the "Bacillus cereus group", which contains other closely related species, including Bacillus cereus, Bacillus thuringiensis, Bacillus mycoides, Bacillus weihenstephanensis, and Bacillus pseudomycoides. B. anthracis naturally occurs in soil environments. The BA5345 genetic marker was used for highly specific detection of B. anthracis with TaqMan probes. The detection limit of a real-time PCR assay was estimated at the level of 16.9 copies (CI95% - 37.4 to 37.86, SD = 0.2; SE = 0.118). Oligonucleotides designed for the targeted sequences (within the tested locus) revealed 100 % homology to B. anthracis strain reference sequences deposited in the database (NCBI) and high specificity to all tested B. anthracis strains. Additional in silico analysis of plasmid markers pag and cap genes with B. anthracis strains included in the database was carried out. Our study clearly indicates that the BA5345 marker can be used with success as a chromosomal marker in routine identification of B. anthracis; moreover, detection of plasmid markers indicates virulence of the examined strains.

  17. Lab-on-a-chip PCR: real time PCR in miniaturized format for HLA diagnostics

    Science.gov (United States)

    Gaertner, Claudia; Becker, Holger; Hlawatsch, Nadine; Klemm, Richard; Moche, Christian; Sewart, René; Frank, Rainer; Willems, Andreas

    2014-05-01

    In case of transplantation or the identification of special metabolic diseases like coeliac disease, HLA typing has to be done fast and reliably with easy-to-handle devices by using limited amount of sample. Against this background a lab-on-a-chip device was realized enabling a fast HLA typing via miniaturized Real-time PCR. Hereby, two main process steps were combined, namely the extraction of DNA from whole blood and the amplification of the target DNA by Real-time PCR giving rise-to a semi-quantitative analysis. For the implementation of both processes on chip, a sample preparation and a real-time module were used. Sample preparation was carried out by using magnetic beads that were stored directly on chip as dry powder, together with all lysis reagents. After purification of the DNA by applying a special buffer regime, the sample DNA was transferred into the PCR module for amplification and detection. Coping with a massively increased surface-to-volume ratio, which results in a higher amount of unspecific binding on the chip surface, special additives needed to be integrated to compensate for this effect. Finally the overall procedure showed a sensitivity comparable to standard Real-time PCR but reduced the duration of analysis to significantly less than one hour. The presented work demonstrates that the combination of lab-on-a-chip PCR with direct optical read-out in a real-time fashion is an extremely promising tool for molecular diagnostics.

  18. Absolute quantification by droplet digital PCR versus analog real-time PCR

    Science.gov (United States)

    Hindson, Christopher M; Chevillet, John R; Briggs, Hilary A; Gallichotte, Emily N; Ruf, Ingrid K; Hindson, Benjamin J; Vessella, Robert L; Tewari, Muneesh

    2014-01-01

    Nanoliter-sized droplet technology paired with digital PCR (ddPCR) holds promise for highly precise, absolute nucleic acid quantification. Our comparison of microRNA quantification by ddPCR and real-time PCR revealed greater precision (coefficients of variation decreased by 37–86%) and improved day-to-day reproducibility (by a factor of seven) of ddPCR but with comparable sensitivity. When we applied ddPCR to serum microRNA biomarker analysis, this translated to superior diagnostic performance for identifying individuals with cancer. PMID:23995387

  19. Detection of Histoplasma capsulatum from clinical specimens by cycling probe-based real-time PCR and nested real-time PCR.

    Science.gov (United States)

    Muraosa, Yasunori; Toyotome, Takahito; Yahiro, Maki; Watanabe, Akira; Shikanai-Yasuda, Maria Aparecida; Kamei, Katsuhiko

    2016-05-01

    We developed new cycling probe-based real-time PCR and nested real-time PCR assays for the detection of Histoplasma capsulatum that were designed to detect the gene encoding N-acetylated α-linked acidic dipeptidase (NAALADase), which we previously identified as an H. capsulatum antigen reacting with sera from patients with histoplasmosis. Both assays specifically detected the DNAs of all H. capsulatum strains but not those of other fungi or human DNA. The limited of detection (LOD) of the real-time PCR assay was 10 DNA copies when using 10-fold serial dilutions of the standard plasmid DNA and 50 DNA copies when using human serum spiked with standard plasmid DNA. The nested real-time PCR improved the LOD to 5 DNA copies when using human serum spiked with standard plasmid DNA, which represents a 10-fold higher than that observed with the real-time PCR assay. To assess the ability of the two assays to diagnose histoplasmosis, we analyzed a small number of clinical specimens collected from five patients with histoplasmosis, such as sera (n = 4), formalin-fixed paraffin-embedded (FFPE) tissue (n = 4), and bronchoalveolar lavage fluid (BALF) (n = 1). Although clinical sensitivity of the real-time PCR assay was insufficiently sensitive (33%), the nested real-time PCR assay increased the clinical sensitivity (77%), suggesting it has a potential to be a useful method for detecting H. capsulatum DNA in clinical specimens.

  20. Digital PCR dynamic range is approaching that of real-time quantitative PCR.

    Science.gov (United States)

    Jones, Gerwyn M; Busby, Eloise; Garson, Jeremy A; Grant, Paul R; Nastouli, Eleni; Devonshire, Alison S; Whale, Alexandra S

    2016-12-01

    Digital PCR (dPCR) has been reported to be more precise and sensitive than real-time quantitative PCR (qPCR) in a variety of models and applications. However, in the majority of commercially available dPCR platforms, the dynamic range is dependent on the number of partitions analysed and so is typically limited to four orders of magnitude; reduced compared with the typical seven orders achievable by qPCR. Using two different biological models (HIV DNA analysis and KRAS genotyping), we have demonstrated that the RainDrop Digital PCR System (RainDance Technologies) is capable of performing accurate and precise quantification over six orders of magnitude thereby approaching that achievable by qPCR.

  1. Quantitative Detection of Respiratory Chlamydia pneumoniae Infection by Real-Time PCR

    OpenAIRE

    Kuoppa, Yvonne; Boman, Jens; Scott, Lena; Kumlin, Urban; Eriksson, Iréne; Allard, Annika

    2002-01-01

    Real-time PCR was evaluated as a quantitative diagnostic method for Chlamydia pneumoniae infection using different respiratory samples. Real-time PCR had efficiency equal to or better than that of nested touchdown PCR. This study confirmed sputum as the best sampling material to detect an ongoing C. pneumoniae infection.

  2. Real-time PCR detection of Plasmodium directly from whole blood and filter paper samples

    OpenAIRE

    Taylor, Brian. J.; Martin, Kimberly A; Arango, Eliana; Agudelo, Olga M; Maestre, Amanda; Yanow, Stephanie K.

    2011-01-01

    Background Real-time PCR is a sensitive and specific method for the analysis of Plasmodium DNA. However, prior purification of genomic DNA from blood is necessary since PCR inhibitors and quenching of fluorophores from blood prevent efficient amplification and detection of PCR products. Methods Reagents designed to specifically overcome PCR inhibition and quenching of fluorescence were evaluated for real-time PCR amplification of Plasmodium DNA directly from blood. Whole blood from clinical s...

  3. Doubling Throughput of a Real-Time PCR

    OpenAIRE

    Christian D. Ahrberg; Pavel Neužil

    2015-01-01

    The invention of polymerase chain reaction (PCR) in 1983 revolutionized many areas of science, due to its ability to multiply a number of copies of DNA sequences (known as amplicons). Here we report on a method to double the throughput of quantitative PCR which could be especially useful for PCR-based mass screening. We concurrently amplified two target genes using only single fluorescent dye. A FAM probe labelled olionucleotide was attached to a quencher for one amplicon while the second one...

  4. Validation of real time PCR assays for use in routine diagnostics of pig diarrhoea

    DEFF Research Database (Denmark)

    Ståhl, Marie; Hjulsager, Charlotte Kristiane; Breum, Solvej Østergaard

    At the National Veterinary Institute in Denmark we want to optimize routine diagnostic analyses by screening samples simultaneously for several agents by real time PCR. Here we present the validation of real time PCR assays for E. coli F4. E coli F18 and Lawsonia intracellularis2 in pig feces...

  5. A rapid and direct real time PCR-based method for identification of Salmonella spp

    DEFF Research Database (Denmark)

    Rodriguez-Lazaro, D.; Hernández, Marta; Esteve, T.

    2003-01-01

    The aim of this work was the validation of a rapid, real-time PCR assay based on TaqMan((R)) technology for the unequivocal identification of Salmonella spp. to be used directly on an agar-grown colony. A real-time PCR system targeting at the Salmonella spp. invA gene was optimized and validated ...

  6. LUX real-time PCR assay for the detection of porcine circovirus type 2.

    Science.gov (United States)

    Vilcek, Stefan; Vlasakova, Michaela; Jackova, Anna

    2010-05-01

    Light Upon eXtension real-time PCR (LUX real-time PCR) assay was developed for the detection of porcine circovirus type 2 (PCV2). The primers flanking a 114 bp fragment were selected from ORF1. The optimized assay could detect 20 viral copies of pBluescript SK+ plasmid containing inserted PCV2 DNA. The dynamic range of quantitative analysis covered a 7-order interval ranging from 20 to 2 x 10(8) genome equivalents per assay with the best results in the range from 2 x 10(2) to 2 x 10(7) viral copies. The LUX real-time PCR assay had a high specificity since it detected PCV2 but not PCV1, CSFV, PRRSV or negative samples. There was good agreement between the LUX real-time PCR and the conventional PCR when lymph nodes from PCV2 infected animals were tested. A comparison of the LUX real-time PCR with the TaqMan PCR and SYBR Green PCR indicated that the amount of viral copies determined using linear calibration curve differed from assay to assay but not more than an order. LUX real-time PCR, similar to the TaqMan PCR, was more specific for generation of fluorogenic signal than SYBR Green PCR.

  7. [Research progress of real-time quantitative PCR method for group A rotavirus detection].

    Science.gov (United States)

    Guo, Yan-Qing; Li, Dan-Di; Duan, Zhao-Jun

    2013-11-01

    Group A rotavirus is one of the most significant etiological agents which causes acute gastroenteritis among infants and young children worldwide. So far, several method which includes electron microscopy (EM), enzyme immunoassay (EIA), reverse transcription-polymerase chain reaction (RT-PCR)and Real-time Quantitative PCR has been established for the detection of rotavirus. Compared with other methods, Real-time quantitative PCR have advantages in specificity, sensitivity, genotyping and quantitative accuracy. This article shows a overview of the application of real-time quantitative PCR technique to detecte group A rotavirus.

  8. Simultaneous detection of ricin and abrin DNA by real-time PCR (qPCR).

    Science.gov (United States)

    Felder, Eva; Mossbrugger, Ilona; Lange, Mirko; Wölfel, Roman

    2012-09-01

    Ricin and abrin are two of the most potent plant toxins known and may be easily obtained in high yield from the seeds using rather simple technology. As a result, both toxins are potent and available toxins for criminal or terrorist acts. However, as the production of highly purified ricin or abrin requires sophisticated equipment and knowledge, it may be more likely that crude extracts would be used by non-governmental perpetrators. Remaining plant-specific nucleic acids in these extracts allow the application of a real-time PCR (qPCR) assay for the detection and identification of abrin or ricin genomic material. Therefore, we have developed a duplex real-time PCR assays for simultaneous detection of ricin and abrin DNA based on the OmniMix HS bead PCR reagent mixture. Novel primers and hybridization probes were designed for detection on a SmartCycler instrument by using 5'-nuclease technology. The assay was thoroughly optimized and validated in terms of analytical sensitivity. Evaluation of the assay sensitivity by probit analysis demonstrated a 95% probability of detection at 3 genomes per reaction for ricin DNA and 1.2 genomes per reaction for abrin DNA. The suitability of the assays was exemplified by detection of ricin and abrin contaminations in a food matrix.

  9. Simultaneous Detection of Ricin and Abrin DNA by Real-Time PCR (qPCR

    Directory of Open Access Journals (Sweden)

    Roman Wölfel

    2012-08-01

    Full Text Available Ricin and abrin are two of the most potent plant toxins known and may be easily obtained in high yield from the seeds using rather simple technology. As a result, both toxins are potent and available toxins for criminal or terrorist acts. However, as the production of highly purified ricin or abrin requires sophisticated equipment and knowledge, it may be more likely that crude extracts would be used by non-governmental perpetrators. Remaining plant-specific nucleic acids in these extracts allow the application of a real-time PCR (qPCR assay for the detection and identification of abrin or ricin genomic material. Therefore, we have developed a duplex real-time PCR assays for simultaneous detection of ricin and abrin DNA based on the OmniMix HS bead PCR reagent mixture. Novel primers and hybridization probes were designed for detection on a SmartCycler instrument by using 5′-nuclease technology. The assay was thoroughly optimized and validated in terms of analytical sensitivity. Evaluation of the assay sensitivity by probit analysis demonstrated a 95% probability of detection at 3 genomes per reaction for ricin DNA and 1.2 genomes per reaction for abrin DNA. The suitability of the assays was exemplified by detection of ricin and abrin contaminations in a food matrix.

  10. Specific PCR and real-time PCR assays for detection and quantitation of 'Candidatus Phytoplasma phoenicium'.

    Science.gov (United States)

    Jawhari, Maan; Abrahamian, Peter; Sater, Ali Abdel; Sobh, Hana; Tawidian, Patil; Abou-Jawdah, Yusuf

    2015-02-01

    Almond witches' broom (AlmWB) is a fast-spreading lethal disease of almond, peach and nectarine associated with 'Candidatus Phytoplasma phoenicium'. The development of PCR and quantitative real-time PCR (qPCR) assays for the sensitive and specific detection of the phytoplasma is of prime importance for early detection of 'Ca. P. phoenicium' and for epidemiological studies. The developed qPCR assay herein uses a TaqMan(®) probe labeled with Black Hole Quencher Plus. The specificity of the PCR and that of the qPCR detection protocols were tested on 17 phytoplasma isolates belonging to 11 phytoplasma 16S rRNA groups, on samples of almond, peach, nectarine, native plants and insects infected or uninfected with the phytoplasma. The developed assays showed high specificity against 'Ca. P. phoenicium' and no cross-reactivity against any other phytoplasma, plant or insect tested. The sensitivity of the developed PCR and qPCR assays was similar to the conventional nested PCR protocol using universal primers. The qPCR assay was further validated by quantitating AlmWB phytoplasma in different hosts, plant parts and potential insect vectors. The highest titers of 'Ca. P. phoenicium' were detected in the phloem tissues of stems and roots of almond and nectarine trees, where they averaged from 10(5) to 10(6) genomic units per nanogram of host DNA (GU/ng of DNA). The newly developed PCR and qPCR protocols are reliable, specific and sensitive methods that are easily applicable to high-throughput diagnosis of AlmWB in plants and insects and can be used for surveys of potential vectors and alternative hosts.

  11. Simplified development of multiplex real-time PCR through master mix augmented by universal fluorogenic reporters.

    Science.gov (United States)

    Wadle, Simon; Lehnert, Michael; Schuler, Friedrich; Köppel, René; Serr, Annerose; Zengerle, Roland; von Stetten, Felix

    2016-01-01

    Mediator probe (MP) PCR is a real-time PCR approach that uses standardized universal fluorogenic reporter oligonucleotides (UR) in conjunction with label-free sequence-specific probes. To enable multiplex real-time MP PCR, we designed a set of five optimized URs with different fluorescent labels. Performance of the optimized URs was verified in multiplex real-time MP PCR for the detection of a pentaplex food panel and a quadruplex methicillin-resistant Staphylococcus aureus (MRSA) panel. Results were comparable to corresponding multiplex hydrolysis probe (HP) PCR, also designated as TaqMan PCR. Analyses of MRSA DNA standards and DNA extracted from patient swab samples showed improved lower limits of detection (LoDs) by a factor of 2-5 when using quadruplex real-time MP PCR instead of HP PCR. The novel set of standardized URs we present here simplifies development of multiplex real-time PCR assays by requiring only the design of label-free probes. In the future, real-time PCR master mixes could be augmented with up to five standardized fluorogenic URs, each emitting light at a different wavelength.

  12. Detection and quantification of Aeromonas salmonicida in fish tissue by real-time PCR.

    Science.gov (United States)

    Bartkova, S; Kokotovic, B; Skall, H F; Lorenzen, N; Dalsgaard, I

    2017-02-01

    Furunculosis, a septicaemic infection caused by the bacterium Aeromonas salmonicida subsp. salmonicida, currently causes problems in Danish seawater rainbow trout production. Detection has mainly been achieved by bacterial culture, but more rapid and sensitive methods are needed. A previously developed real-time PCR assay targeting the plasmid encoded aopP gene of A. salmonicida was, in parallel with culturing, used for the examination of five organs of 40 fish from Danish freshwater and seawater farms. Real-time PCR showed overall a higher frequency of positives than culturing (65% of positive fish by real-time PCR compared to 30% by a culture approach). Also, no real-time PCR-negative samples were found positive by culturing. A. salmonicida was detected by real-time PCR, though not by culturing, in freshwater fish showing no signs of furunculosis, indicating possible presence of carrier fish. In seawater fish examined after an outbreak and antibiotics treatment, real-time PCR showed the presence of the bacterium in all examined organs (1-482 genomic units mg(-1) ). With a limit of detection of 40 target copies (1-2 genomic units) per reaction, a high reproducibility and an excellent efficiency, the present real-time PCR assay provides a sensitive tool for the detection of A. salmonicida. © 2016 John Wiley & Sons Ltd.

  13. Comprehensive GMO detection using real-time PCR array: single-laboratory validation.

    Science.gov (United States)

    Mano, Junichi; Harada, Mioko; Takabatake, Reona; Furui, Satoshi; Kitta, Kazumi; Nakamura, Kosuke; Akiyama, Hiroshi; Teshima, Reiko; Noritake, Hiromichi; Hatano, Shuko; Futo, Satoshi; Minegishi, Yasutaka; Iizuka, Tayoshi

    2012-01-01

    We have developed a real-time PCR array method to comprehensively detect genetically modified (GM) organisms. In the method, genomic DNA extracted from an agricultural product is analyzed using various qualitative real-time PCR assays on a 96-well PCR plate, targeting for individual GM events, recombinant DNA (r-DNA) segments, taxon-specific DNAs, and donor organisms of the respective r-DNAs. In this article, we report the single-laboratory validation of both DNA extraction methods and component PCR assays constituting the real-time PCR array. We selected some DNA extraction methods for specified plant matrixes, i.e., maize flour, soybean flour, and ground canola seeds, then evaluated the DNA quantity, DNA fragmentation, and PCR inhibition of the resultant DNA extracts. For the component PCR assays, we evaluated the specificity and LOD. All DNA extraction methods and component PCR assays satisfied the criteria set on the basis of previous reports.

  14. Real-time PCR Detection of Food-borne Pathogenic Salmonella spp

    DEFF Research Database (Denmark)

    Malorny, B.; Mäde, D.; Löfström, Charlotta

    2013-01-01

    -limiting gastrointestinal disease in a wide range of mammalian hosts. Within the last decade, numerous real-time PCR assays have been developed for rapid detection of salmonellae in potentially contaminated food or feed. Some of them were extensively validated and are useful for diagnostic laboratories. Furthermore......, effective sample preparation prior to the analytical real-time PCR assay avoids inhibitory substances disturbing the PCR and contributes to a high sensitivity. We discuss appropriate sample preparation methods including enrichment procedures for various food items and analytical real-time PCR assays...... for the detection of Salmonella and give a state-of-the-art summary what targets are used and how valid the assays are to apply as diagnostic tool. Furthermore, recommendations for selection of an appropriate real-time PCR method are presented....

  15. Identification of Aedes aegypti and its Respective Life Stages by Real-Time PCR

    Science.gov (United States)

    2004-06-01

    RTO-MP-HFM-108 22 - 1 Identification of Aedes aegypti and its Respective Life Stages by Real - Time PCR James C. McAvin1*; Major David E...Stages by Real - Time PCR 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK...grade water Identification of Aedes aegypti and its Respective Life Stages by Real - Time PCR RTO-MP-HFM-108 22 - 3 for no template controls

  16. A High-Throughput Pipeline for the Design of Real-Time PCR Signatures

    Science.gov (United States)

    2010-06-23

    available soon. A high-throughput pipeline for the design of real - time PCR signatures BMC Bioinformatics 2010, 11:340 doi:10.1186/1471-2105-11-340 Ravi...AND SUBTITLE A high-throughput pipeline for the design of real - time PCR signatures 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER...Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 1 A high-throughput pipeline for the design of real - time PCR signatures Ravi Vijaya Satya

  17. Detection of influenza A virus RNA in birds by optimized Real-Time PCR system

    Institute of Scientific and Technical Information of China (English)

    Ilinykh Ph A; Shestopalova EM; Khripko Yu I; Durimanov AG; Sharshov KA; Shestopalov AM

    2010-01-01

    Objective: To evaluate the use of Real-Time PCR system based on specific amplification of matrix protein gene fragment for influenza A virus RNA detection in cloacal swabs from wild birds. Methods:Sensitivity, specificity and reproducibility of analysis results were identified. Study of cloacal swabs from wild birds for influenza A virus presence was performed. Results:Reproducibility of low concentrations of virus detection in samples by Real-Time PCR was significantly higher than that of detection based on cytopathic effect of viruses grown on MDCK cell culture. Conclusions: Real-Time PCR system for influenza A virus RNA detection is developed and applied for virus surveillance study.

  18. Development of a real-time PCR assay for detection and quantification of Anaplasma ovis infection.

    Science.gov (United States)

    Chi, Q; Liu, Z; Li, Y; Yang, J; Chen, Z; Yue, C; Luo, J; Yin, H

    2013-11-01

    Anaplasma ovis is a tick-borne intra-erythrocytic rickettsial pathogen of small ruminants. Real-time PCR possesses merits of rapidity, accuracy, reliability, automation and ease of standardization, but has not been used for detection of A. ovis, to the best of our knowledge. In this study, a real-time PCR assay was developed for detection and quantification of A. ovis. Species-specific primers and TaqMan probe were designed based on the gltA gene. No cross-reactions were observed with Anaplasma marginale, Anaplasma bovis, Anaplasma phagocytophilum, Borrelia burgdorferi s. l., Chlamydia psittaci, Mycoplasma mycoides, Theileria luwenshuni and Babesia sp. Xinjiang isolate. Analytic sensitivity results revealed that real-time PCR could detect as few as 10 copies of the gltA gene. The performance of real-time PCR was assessed by testing 254 blood samples from goats and comparing with the results from conventional PCR. This demonstrated that the real-time PCR assay was significantly more sensitive than conventional PCR. Our results indicated that real-time PCR is a useful approach for detecting A. ovis infections and has potential as an alternative tool for ecological and epidemiological surveillance of ovine anaplasmosis. © 2013 Blackwell Verlag GmbH.

  19. Oligonucleotide chip, real-time PCR and sequencing for genotyping of hepatitis B virus

    Institute of Scientific and Technical Information of China (English)

    Yong-Zhong Wang; Guo-Xiang Wu; Li-Bo Luo; Min Chen; Li-Hua Ruan

    2007-01-01

    AIM: To compare the oligonucleotide chip, real-time PCR and sequencing for genotyping of hepatitis B virus in Chinese patients with chronic hepatitis B.METHODS: Mixture of samples with different genotypes and clinical serum samples from 126 chronic hepatitis B patients was tested for hepatitis B virus genotypes by oligonucleotide chip, real-time PCR and sequencing of PCR products, respectively. Clinical performances, time required and costs of the three assays were evaluated.RESULTS: Oligonucleotide chips and real-time PCR detected 1% and 0.1% genotypes, respectively, in mixed samples. Of the 126 clinical samples from patients with chronic hepatitis B, genotype B was detected in 41(33%), 41 (33%) and 45 (36%) samples, and genotype C in 76 (60%), 76 (60%) and 81 (64%) samples, by oligonucleotide chip, real-time PCR and sequencing,respectively. Oligonucleotide chip and real-time PCR detected mixed genotypes B and C in 9 samples. Realtime PCR was the rapidest and cheapest among the three assays.CONCLUSION: Oligonucleotide chip and real-time PCR are able to detect mixed genotypes, while sequencing only detects the dominant genotype in clinical samples.

  20. Fast detection of Noroviruses using a real-time PCR assay and automated sample preparation

    Directory of Open Access Journals (Sweden)

    Schmid Michael

    2004-06-01

    Full Text Available Abstract Background Noroviruses (NoV have become one of the most commonly reported causative agents of large outbreaks of non-bacterial acute gastroenteritis worldwide as well as sporadic gastroenteritis in the community. Currently, reverse transcriptase polymerase chain reaction (RT-PCR assays have been implemented in NoV diagnosis, but improvements that simplify and standardize sample preparation, amplification, and detection will be further needed. The combination of automated sample preparation and real-time PCR offers such refinements. Methods We have designed a new real-time RT-PCR assay on the LightCycler (LC with SYBR Green detection and melting curve analysis (Tm to detect NoV RNA in patient stool samples. The performance of the real-time PCR assay was compared with that obtained in parallel with a commercially available enzyme immunoassay (ELISA for antigen detection by testing a panel of 52 stool samples. Additionally, in a collaborative study with the Baden-Wuerttemberg State Health office, Stuttgart (Germany the real-time PCR results were blindly assessed using a previously well-established nested PCR (nPCR as the reference method, since PCR-based techniques are now considered as the "gold standard" for NoV detection in stool specimens. Results Analysis of 52 clinical stool samples by real-time PCR yielded results that were consistent with reference nPCR results, while marked differences between the two PCR-based methods and antigen ELISA were observed. Our results indicate that PCR-based procedures are more sensitive and specific than antigen ELISA for detecting NoV in stool specimens. Conclusions The combination of automated sample preparation and real-time PCR provided reliable diagnostic results in less time than conventional RT-PCR assays. These benefits make it a valuable tool for routine laboratory practice especially in terms of rapid and appropriate outbreak-control measures in health-care facilities and other settings.

  1. RDML: structured language and reporting guidelines for real-time quantitative PCR data

    NARCIS (Netherlands)

    Lefever, S.; Hellemans, J.; Pattyn, F.; Przybylski, D.R.; Taylor, C.; Geurts, R.; Untergasser, A.; Vandesompele, J.

    2009-01-01

    The XML-based Real-Time PCR Data Markup Language (RDML) has been developed by the RDML consortium (http://www.rdml.org) to enable straightforward exchange of qPCR data and related information between qPCR instruments and third party data analysis software, between colleagues and collaborators and be

  2. Development of a Real-time PCR test for porcine group A rotavirus diagnosis

    Directory of Open Access Journals (Sweden)

    Elizabeth C.M. Marconi

    2015-01-01

    Full Text Available Group A Rotavirus (RVA is one of the most common causes of diarrhea in humans and several animal species. A SYBR-Green Real-Time polymerase chain reaction (PCR was developed to diagnose RVA from porcine fecal samples, targeting amplification of a 137-bp fragment of nonstructural protein 5 (NSP5 gene using mRNA of bovine NADH-desidrogenase-5 as exogenous internal control. Sixty-five samples were tested (25 tested positive for conventional PCR and genetic sequencing. The overall agreement (kappa was 0.843, indicating 'very good' concordance between tests, presenting 100% of relative sensitivity (25+ Real Time PCR/25+ Conventional PCR and 87.5% of relative sensitivity (35- Real Time PCR/40- Conventional PCR. The results also demonstrated high intra- and inter-assay reproducibility (coefficient of variation ≤1.42%; thus, this method proved to be a fast and sensitive approach for the diagnosis of RVA in pigs.

  3. [Analytical performances of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine].

    Science.gov (United States)

    De Monte, Anne; Cannavo, Isabelle; Caramella, Anne; Ollier, Laurence; Giordanengo, Valérie

    2016-01-01

    Congenital cytomegalovirus (CMV) infection is the leading cause of sensoneurinal disability due to infectious congenital disease. The diagnosis of congenital CMV infection is based on the search of CMV in the urine within the first two weeks of life. Viral culture of urine is the gold standard. However, the PCR is highly sensitive and faster. It is becoming an alternative choice. The objective of this study is the validation of real-time PCR by Abbott RealTime CMV with m2000 for the detection of cytomegalovirus in urine. Repeatability, reproducibility, detection limit and inter-sample contamination were evaluated. Urine samples from patients (n=141) were collected and analyzed simultaneously in culture and PCR in order to assess the correlation of these two methods. The sensitivity and specificity of PCR were also calculated. The Abbott RealTime CMV PCR in urine is an automated and sensitive method (detection limit 200 UI/mL). Fidelity is very good (standard deviation of repeatability: 0.08 to 0.15 LogUI/mL and reproducibility 0.18 LogUI/mL). We can note a good correlation between culture and Abbott RealTime CMV PCR (kappa 96%). When considering rapid culture as reference, real-time PCR was highly sensitive (100%) and specific (98.2%). The real-time PCR by Abbott RealTime CMV with m2000 is optimal for CMV detection in urine.

  4. 应用real-time PCR法快速定量人类粪便中双歧杆菌的研究%A fast quantification for Bifidobacteria in human feces by real-time PCR

    Institute of Scientific and Technical Information of China (English)

    于静; 文姝; 唐立

    2009-01-01

    Objective To build a fast and accurate method of quantification for Bifidobacteria in human feces. Method Traditional culture, common PCR, real-time PCR were used. Result (1) The inhibitors in the feces samples were removed when the samples were centrifuged, washed and diluted,so that the Bifidobacteria in the feces samples could be directly quantitated by PCR and real-time PCR. (2) The direct semiquantitation by PCR established in this study showed a satisfactory distinguishability when Bifidobacteria in feces samples was between 10~3 ~10~7CFU /ml. There was no obvious difference between the result from RT-PCR quantification and that from cultured method (P > 0.05); The direct quantita-tion by PCR showed a satisfactory distinguishability when Bifidobacteria in feces samples was between 10~1 ~ 10~7CFU /ml, without obvious difference between the result from RT-PCR and that from cultured method (P > 0. 05). Conclusion Bifidobacteria in feces samples can be directly quantitated or semiquantitated by real-time PCR method or common PCR method.%目的 建立快速、准确从粪便标本中定量双歧杆菌的RT-PCR技术.方法 传统培养定量法,普通PCR定量法,real-time PCR 比较测量.结果 (1)粪便标本前处理采取简单的离心和清洗、稀释步骤能去除粪便标本中的抑制物,实现不提取 DNA直接进行PCR、real-time定量粪便中双歧杆菌.(2)本实验建立的PCR方法直接半定量粪便双歧杆菌技术在双歧杆菌值介于10~3~10~7CFU/ml时具有较好的分辨率,粪便标本普通PCR得理论菌数与培养得菌数值之间差异无显著性(P>0.05);real-time PCR直接定量双歧杆菌技术在双歧杆菌值介于10~1~10~7CFU /ml时具有较好的分辨率,粪便标本RT-PCR得理论菌数与培养得菌数值之间差异无显著性(P>0.05).结论 利用PCR、real-time PCR直接半定量和定量粪便中的双歧杆菌可行.

  5. To Normalize the Using of Quantitative Real-time Reverse Transcription PCR%Real time RT-qPCR 检测规范化

    Institute of Scientific and Technical Information of China (English)

    马俊彦; 林俊

    2010-01-01

    Real time RT-qPCR(real-time quantitatire reverse transcription-PCR)是一种快速、简便、准确、灵敏、成本低廉的基因检测技术,被认为是目前检测基因在转录水平表达的金标准.研究发现Real time RT-qPCR的检测结果会受到实验设计、引物、模板的质量、内参的选择及数据分析的方法等多个因素的影响,规范实验设计及操作是得到可靠结论的前提和必要条件.对近年来国内外涉及Real time RT-qPCR整个实验流程及数据发表的一些规范及标准进行综述,以便规范实验设计及操作,加强实验质量控制,促进研究结果的推广,和更好地发挥其应用价值.

  6. Recovery of DNA of Giardia intestinalis cysts from surface water concentrates measured with PCR and real time PCR

    Directory of Open Access Journals (Sweden)

    Adamska M.

    2011-11-01

    Full Text Available The most important restriction for the detection in water samples is the low concentration of Giardia intestinalis cysts, additional difficulty is the presence of PCR inhibitors. We have carried out trials in order to assess the sensitivity of semi-nested PCR and TaqMan real time PCR on the basis of DNA extracted from G. intestinalis cysts coming from spiked environmental and distilled water samples, filtrated with the use of Filta-Max® equipment (1623 Method. Removal of inhibitors was carried out with addition of BSA in different concentrations. During the filtration and concentration of water samples, losses of cysts have been recorded. Moreover, addition of BSA to the PCR and real time PCR mix increases the sensitivity of reaction. The optimal concentration of BSA for semi-nested PCR was 15 and 20 ng/μl, whereas for real time PCR 5 ng/μl.

  7. Comparison of real-time PCR protocols in detection and quantification of fruit tree 16SrX group phytoplasmas

    OpenAIRE

    Kiss Tomas; Necas Tomas; Necasova Jana

    2016-01-01

    In this work, two real-time PCR protocols based on intercalating dye and two on hydrolysis probes were tested using field collected fruit tree samples infected by 16SrX group (AP, PD and ESFY) phytoplasmas. Specificity and sensitivity of protocols and amplification efficiency were the main testing parameters. Results of real-time PCR protocols were compared to nested PCR. All real-time PCR protocols confirmed their specificity of detection. All real-time PC...

  8. Quantitative detection of hazelnut (Corylus avellana) in cookies: ELISA versus real-time PCR.

    Science.gov (United States)

    Platteau, Céline; De Loose, Marc; De Meulenaer, Bruno; Taverniers, Isabel

    2011-11-09

    Hazelnuts (Corylus avellana) are used widely in the food industry, especially in confectionery, where they are used raw, roasted, or in a processed formulation (e.g., praline paste and hazelnut oil). Hazelnuts contain multiple allergenic proteins, which can induce an allergic reaction associated with symptoms ranging from mild irritation to life-threatening anaphylactic shock. To date, immunochemical (e.g., ELISA or dipstick) and PCR-based analyses are the only methods available that can be applied as routine tests. The aim of this study is to make a comparative evaluation of the effectiveness of ELISA and real-time PCR in detecting and correctly quantifying hazelnut in food model systems. To this end, the performances of two commercial ELISAs were compared to those of two commercial and one in-house-developed real-time PCR assays. The results showed that although ELISA seemed to be more sensitive compared to real-time PCR, both detection techniques suffered from matrix effects and lacked robustness with regard to food processing. As these impacts were highly variable among the different evaluated assays (both ELISA and real-time PCR), no firm conclusion can be made as to which technique is suited best to detect hazelnut in (processed) food products. In this regard, the current lack of appropriate DNA calibrators to quantify an allergenic ingredient by means of real-time PCR is highlighted.

  9. Real-time PCR Machine System Modeling and a Systematic Approach for the Robust Design of a Real-time PCR-on-a-Chip System

    Directory of Open Access Journals (Sweden)

    Da-Sheng Lee

    2010-01-01

    Full Text Available Chip-based DNA quantification systems are widespread, and used in many point-of-care applications. However, instruments for such applications may not be maintained or calibrated regularly. Since machine reliability is a key issue for normal operation, this study presents a system model of the real-time Polymerase Chain Reaction (PCR machine to analyze the instrument design through numerical experiments. Based on model analysis, a systematic approach was developed to lower the variation of DNA quantification and achieve a robust design for a real-time PCR-on-a-chip system. Accelerated lift testing was adopted to evaluate the reliability of the chip prototype. According to the life test plan, this proposed real-time PCR-on-a-chip system was simulated to work continuously for over three years with similar reproducibility in DNA quantification. This not only shows the robustness of the lab-on-a-chip system, but also verifies the effectiveness of our systematic method for achieving a robust design.

  10. Sequence polymorphism can produce serious artifacts in real-time PCR assays: lessons from Pacific oysters

    Science.gov (United States)

    Since it was first described in the mid-1990s, quantitative real time PCR (Q-PCR) has been widely used in many fields of biomedical research and molecular diagnostics. This method is routinely used to validate whole transcriptome analyses such as DNA microarrays, suppressive subtractive hybridizati...

  11. Quantitative real-time RT-PCR and chromogenic in situ hybridization

    DEFF Research Database (Denmark)

    Rosa, Fabíola E; Silveira, Sara M; Silveira, Cássia G T;

    2009-01-01

    . METHODS: To elucidate the molecular profile of HER-2 status, mRNA and protein expression in 75 invasive breast carcinomas were analyzed by real time quantitative RT-PCR (qRT-PCR) and IHC, respectively. Amplifications were evaluated in 43 of these cases by CISH and in 11 by FISH. RESULTS: The concordance...

  12. Interlaboratory Comparison of Real-time PCR Protocols for Quantification of General Fecal Indicator Bacteria

    Science.gov (United States)

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized proto...

  13. Evaluation of probe chemistries and platforms to improve the detection limit of real-time PCR

    DEFF Research Database (Denmark)

    Reynisson, E.; Josefsen, Mathilde Hartmann; Krause, Michael

    2006-01-01

    A validated PCR-based Salmonella method targeting a 94-bp sequence of the ttr gene was used as a model to compare six different combinations of reporter and quencher dyes of a TaqMan probe, on three different instruments, to improve the detection limit in a real-time PCR assay with the aim of a s...

  14. Development of a real-time microchip PCR system for portable plant disease diagnosis.

    Directory of Open Access Journals (Sweden)

    Chiwan Koo

    Full Text Available Rapid and accurate detection of plant pathogens in the field is crucial to prevent the proliferation of infected crops. Polymerase chain reaction (PCR process is the most reliable and accepted method for plant pathogen diagnosis, however current conventional PCR machines are not portable and require additional post-processing steps to detect the amplified DNA (amplicon of pathogens. Real-time PCR can directly quantify the amplicon during the DNA amplification without the need for post processing, thus more suitable for field operations, however still takes time and require large instruments that are costly and not portable. Microchip PCR systems have emerged in the past decade to miniaturize conventional PCR systems and to reduce operation time and cost. Real-time microchip PCR systems have also emerged, but unfortunately all reported portable real-time microchip PCR systems require various auxiliary instruments. Here we present a stand-alone real-time microchip PCR system composed of a PCR reaction chamber microchip with integrated thin-film heater, a compact fluorescence detector to detect amplified DNA, a microcontroller to control the entire thermocycling operation with data acquisition capability, and a battery. The entire system is 25 × 16 × 8 cm(3 in size and 843 g in weight. The disposable microchip requires only 8-µl sample volume and a single PCR run consumes 110 mAh of power. A DNA extraction protocol, notably without the use of liquid nitrogen, chemicals, and other large lab equipment, was developed for field operations. The developed real-time microchip PCR system and the DNA extraction protocol were used to successfully detect six different fungal and bacterial plant pathogens with 100% success rate to a detection limit of 5 ng/8 µl sample.

  15. Rapid diagnosis of sepsis with TaqMan-Based multiplex real-time PCR.

    Science.gov (United States)

    Liu, Chang-Feng; Shi, Xin-Ping; Chen, Yun; Jin, Ye; Zhang, Bing

    2017-05-17

    The survival rate of septic patients mainly depends on a rapid and reliable diagnosis. A rapid, broad range, specific and sensitive quantitative diagnostic test is the urgent need. Thus, we developed a TaqMan-Based Multiplex real-time PCR assays to identify bloodstream pathogens within a few hours. Primers and TaqMan probes were designed to be complementary to conserved regions in the 16S rDNA gene of different kinds of bacteria. To evaluate accurately, sensitively, and specifically, the known bacteria samples (Standard strains, whole blood samples) are determined by TaqMan-Based Multiplex real-time PCR. In addition, 30 blood samples taken from patients with clinical symptoms of sepsis were tested by TaqMan-Based Multiplex real-time PCR and blood culture. The mean frequency of positive for Multiplex real-time PCR was 96% at a concentration of 100 CFU/mL, and it was 100% at a concentration greater than 1000 CFU/mL. All the known blood samples and Standard strains were detected positively by TaqMan-Based Multiplex PCR, no PCR products were detected when DNAs from other bacterium were used in the multiplex assay. Among the 30 patients with clinical symptoms of sepsis, 18 patients were confirmed positive by Multiplex real-time PCR and seven patients were confirmed positive by blood culture. TaqMan-Based Multiplex real-time PCR assay with highly sensitivity, specificity and broad detection range, is a rapid and accurate method in the detection of bacterial pathogens of sepsis and should have a promising usage in the diagnosis of sepsis. © 2017 Wiley Periodicals, Inc.

  16. Real-time PCR assays for hepatitis B virus DNA quantification may require two different targets.

    Science.gov (United States)

    Liu, Chao; Chang, Le; Jia, Tingting; Guo, Fei; Zhang, Lu; Ji, Huimin; Zhao, Junpeng; Wang, Lunan

    2017-05-12

    Quantification Hepatitis B virus (HBV) DNA plays a critical role in the management of chronic HBV infections. However, HBV is a DNA virus with high levels of genetic variation, and drug-resistant mutations have emerged with the use of antiviral drugs. If a mutation caused a sequence mismatched in the primer or probe of a commercial DNA quantification kit, this would lead to an underestimation of the viral load of the sample. The aim of this study was to determine whether commercial kits, which use only one pair of primers and a single probe, accurately quantify the HBV DNA levels and to develop an improved duplex real-time PCR assay. We developed a new duplex real-time PCR assay that used two pairs of primers and two probes based on the conserved S and C regions of the HBV genome. We performed HBV DNA quantitative detection of HBV samples and compared the results of our duplex real-time PCR assays with the COBAS TaqMan HBV Test version 2 and Daan real-time PCR assays. The target region of the discordant sample was amplified, sequenced, and validated using plasmid. The results of the duplex real-time PCR were in good accordance with the commercial COBAS TaqMan HBV Test version 2 and Daan real-time PCR assays. We showed that two samples from Chinese HBV infections underestimated viral loads when quantified by the Roche kit because of a mismatch between the viral sequence and the reverse primer of the Roche kit. The HBV DNA levels of six samples were undervalued by duplex real-time PCR assays of the C region because of mutations in the primer of C region. We developed a new duplex real-time PCR assay, and the results of this assay were similar to the results of commercial kits. The HBV DNA level could be undervalued when using the COBAS TaqMan HBV Test version 2 for Chinese HBV infections owing to a mismatch with the primer/probe. A duplex real-time PCR assay based on the S and C regions could solve this problem to some extent.

  17. Analysis of Herpes Simplex Virus in Suspected Encephalitis, Keratitis and Dermal Infections Using Real- Time PCR

    Directory of Open Access Journals (Sweden)

    Nasrin Aliabadi

    2014-03-01

    Full Text Available Background & Objectives: Herpes viruses can cause diseases in the clinical range. The virus can cause infection in various body parts, especially eyes and nervous system. The aim of this study was at evaluating  the Real-Time TaqMan probe PCR in diagnosing and monitoring of the patients with suspected HSV infections.Materials & Methods: More than a thousand patients with suspected HSV infections were collected. The samples were analyzed by Real-time PCR assays. DNA was extracted according to manufacturer’s instruction (Invisorb Spin Virus DNA mini Kit, Germany. The Real-Time PCR assay was performed with the primer Design TM genesis for herpes simplex virus (Primer Design, UK.  Results: Total of 44 (5.6%, 118 (26.8%, 23(11.7%, 13 (5.6 % and 65(45.5% patients out of  herpes simplex encephalitis suspected group, HSK suspected, patients with suspected systemic HSV infection, HSV skin suspected ones and oropharyngeal HSV infection suspected patients respectively were found to be positive by Real-time PCR assays..Conclusion: As indicated by the results, Real-time PCR assay, with high sensitivity and specificity, can help in early diagnosis. The viral load obtained by this method, can be the best marker in a person for following the therapeutic effect.

  18. Development of quantitative real-time PCR for detection and enumeration of Enterobacteriaceae.

    Science.gov (United States)

    Takahashi, Hajime; Saito, Rumi; Miya, Satoko; Tanaka, Yuichiro; Miyamura, Natsumi; Kuda, Takashi; Kimura, Bon

    2017-04-04

    The family Enterobacteriaceae, members of which are widely distributed in the environment, includes many important human pathogens. In this study, a rapid real-time PCR method targeting rplP, coding for L16 protein, a component of the ribosome large subunit, was developed for enumerating Enterobacteriaceae strains, and its efficiency was evaluated using naturally contaminated food products. The rplP-targeted real-time PCR amplified Enterobacteriaceae species with Ct values of 14.0-22.8, whereas the Ct values for non-Enterobacteriaceae species were >30, indicating the specificity of this method for the Enterobacteriaceae. Using a calibration curve of Ct=-3.025 (log CFU/g)+37.35, which was calculated from individual plots of the cell numbers in different concentrations of 5 Enterobacteriaceae species, the rplP-targeted real-time PCR was applied to 51 food samples. A real-time PCR and culture methods was obtained in a majority of the food samples (81.8%), with good correlation (r(2)=0.8285). This study demonstrated that the rplP-targeted real-time PCR method could detect and enumerate Enterobacteriaceae species in foods rapidly and accurately, and therefore, it can be used for the microbiological risk analysis of foods.

  19. EFFECTS OF PROPOLIS EXTRACTS IN CHICKENS DIET AGAINST SALMONELLA TYPHIMURIUM DETECTED BY REAL-TIME PCR

    Directory of Open Access Journals (Sweden)

    Lukáš Hleba

    2011-10-01

    Full Text Available The aim of this study was to follow the effect of propolis extractsin chickens feed against colonization of GIT (gastrointestinal tract with Salmonella spp. by Step One real-time PCR. Propolis has been used in folk medicine since ancient times due to its many biological properties, such as antimicrobial, anti-inflammatory, antioxidant, immunomodulatory activities, among others. Propolis extracts was applied to chickens feeds in four groups with different concentration of propolis. We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and MicroSEQ® Salmonella spp. Detection Kit for pursuance the real-time PCR(Applied Biosystems. In the investigated samples without incubation we could detect strain of Salmonella spp. in twenty of twenty five samples (swabs, as well as internal positive control (IPC, which was positive in all samples. Our results indicate positive effect of propolis against colonization of GIT (gastrointestinal tract with Salmonellaspp. in all experimental groups. This Step One real-time PCR assay is extremely useful for any laboratory equipped by real-time PCR. Thus, these results proved real-time PCR to be useful as a rapid diagnostic test for the direct detection of pathogens in food, without the need of enrichment steps.

  20. Interlaboratory Validation for a Real-Time PCR Salmonella Detection Method Using the ABI 7500 FAST Real-Time PCR System.

    Science.gov (United States)

    Cheng, Chorng-Ming; Doran, Tara; Lin, Wen; Chen, Kai-Shun; Williams-Hill, Donna; Pamboukian, Ruiqing

    2015-06-01

    Sixteen FERN (Food Emergency Response Network) member laboratories collaborated in this study to verify extension of the real-time PCR Salmonella detection method originally designed for the single-tube Cepheid SmartCycler II and validated against the Salmonella method of the U. S. Food and Drug Administration Bacteriological Analytical Manual to the Applied Biosystems (ABI) 7500 FAST Real-Time PCR system multiwell plate platform. Four foods were selected for this study: chili powder, soft cheese, fish, and tomatoes; these foods represent products that are commonly analyzed for the presence of Salmonella for regulatory purposes. Each food consisted of six uninoculated control samples, six samples inoculated with low Salmonella levels (target 1 to 5 CFU/25 g), and six samples inoculated with high levels (target 10 to 50 CFU/25 g). All samples were tested for Salmonella using the 24-h quantitative PCR (qPCR) method for detecting Salmonella, which utilizes modified buffered peptone water as the sole enrichment medium and an internal control for the qPCR. Each of these 18 samples was individually analyzed for Salmonella by the collaborating laboratories using both the ABI 7500 FAST system (alternative method) and the SmartCycler II system (reference method). Statistical analysis of the data revealed no significant difference (P ≥ 0.05) between these two qPCR platforms except for the chili powder samples. The differences noted with chili powder (P = 0.0455) were attributed to the enhanced sensitivity of the ABI 7500 FAST system compared with the SmartCycler II system. The detection limit of both qPCR methods was 0.02 to 0.15 CFU/g. These results provide a solid basis for extending the 24-h qPCR Salmonella method to the ABI 7500 FAST system for high-throughput detection of Salmonella in foods.

  1. A standard curve based method for relative real time PCR data processing

    Directory of Open Access Journals (Sweden)

    Krause Andreas

    2005-03-01

    Full Text Available Abstract Background Currently real time PCR is the most precise method by which to measure gene expression. The method generates a large amount of raw numerical data and processing may notably influence final results. The data processing is based either on standard curves or on PCR efficiency assessment. At the moment, the PCR efficiency approach is preferred in relative PCR whilst the standard curve is often used for absolute PCR. However, there are no barriers to employ standard curves for relative PCR. This article provides an implementation of the standard curve method and discusses its advantages and limitations in relative real time PCR. Results We designed a procedure for data processing in relative real time PCR. The procedure completely avoids PCR efficiency assessment, minimizes operator involvement and provides a statistical assessment of intra-assay variation. The procedure includes the following steps. (I Noise is filtered from raw fluorescence readings by smoothing, baseline subtraction and amplitude normalization. (II The optimal threshold is selected automatically from regression parameters of the standard curve. (III Crossing points (CPs are derived directly from coordinates of points where the threshold line crosses fluorescence plots obtained after the noise filtering. (IV The means and their variances are calculated for CPs in PCR replicas. (V The final results are derived from the CPs' means. The CPs' variances are traced to results by the law of error propagation. A detailed description and analysis of this data processing is provided. The limitations associated with the use of parametric statistical methods and amplitude normalization are specifically analyzed and found fit to the routine laboratory practice. Different options are discussed for aggregation of data obtained from multiple reference genes. Conclusion A standard curve based procedure for PCR data processing has been compiled and validated. It illustrates that

  2. Cloning and evaluation of reference genes for quantitative real-time PCR analysis in Amorphophallus

    OpenAIRE

    Kai Wang; Yi Niu; Qijun Wang; Haili Liu; Yi Jin; Shenglin Zhang

    2017-01-01

    Quantitative real-time reverse transcription PCR (RT-qPCR) has been widely used in the detection and quantification of gene expression levels because of its high accuracy, sensitivity, and reproducibility as well as its large dynamic range. However, the reliability and accuracy of RT-qPCR depends on accurate transcript normalization using stably expressed reference genes. Amorphophallus is a perennial plant with a high content of konjac glucomannan (KGM) in its corm. This crop has been used a...

  3. Detection of Food Allergens by Taqman Real-Time PCR Methodology.

    Science.gov (United States)

    García, Aina; Madrid, Raquel; García, Teresa; Martín, Rosario; González, Isabel

    2017-01-01

    Real-time PCR (polymerase chain reaction) has shown to be a very effective technology for the detection of food allergens. The protocol described herein consists on a real-time PCR assay targeting the plant ITS (Internal Transcribed Spacer) region, using species-specific primers and hydrolysis probes (Taqman) dual labeled with a reporter fluorophore at the 5' end (6-carboxyfluorescein, FAM) and a quencher fluorophore at the 3' end (Blackberry, BBQ). The species-specific real-time PCR systems (primers/probe) described in this work allowed the detection of different nuts (peanut, hazelnut, pistachio, almond, cashew, macadamia, walnut and pecan), common allergens present in commercial food products, with a detection limit of 0.1 mg/kg.

  4. A Basic Guide to Real Time PCR in Microbial Diagnostics: Definitions, Parameters, and Everything

    Science.gov (United States)

    Kralik, Petr; Ricchi, Matteo

    2017-01-01

    Real time PCR (quantitative PCR, qPCR) is now a well-established method for the detection, quantification, and typing of different microbial agents in the areas of clinical and veterinary diagnostics and food safety. Although the concept of PCR is relatively simple, there are specific issues in qPCR that developers and users of this technology must bear in mind. These include the use of correct terminology and definitions, understanding of the principle of PCR, difficulties with interpretation and presentation of data, the limitations of qPCR in different areas of microbial diagnostics and parameters important for the description of qPCR performance. It is not our intention in this review to describe every single aspect of qPCR design, optimization, and validation; however, it is our hope that this basic guide will help to orient beginners and users of qPCR in the use of this powerful technique. PMID:28210243

  5. The importance of set up time and temperature in real-time PCR; an essential reminder.

    Science.gov (United States)

    Cassidy, Hayley; MacLean, Alasdair; Gunson, Rory

    2017-05-01

    Non-specific amplification can arise in real-time PCR when temperatures are above 4°C during PCR set up. Pressure of high throughput tests, particularly in a clinical setting, can lead to short cuts being taken during PCR set up. This study set out to evaluate the outcome of exposing a real-time PCR assay to increasing durations of room temperature prior to PCR amplification. A real-time PCR assay was exposed to increasing durations of room temperature prior to PCR amplification. We found that reactions left at room temperature for 30min or more produced non-specific traces in the negative controls which could be mistaken for weak positive traces. In addition we found that the fluorescence of positive control traces was significantly reduced indicating reduced reaction efficiency, however the Ct valves were comparable between all reactions highlighting that control Ct monitoring alone would not have detected this issue. This study acts as a reminder for PCR users to set up reactions on ice/chill blocks prior to PCR amplification. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Detection of Zika virus by SYBR green one-step real-time RT-PCR.

    Science.gov (United States)

    Xu, Ming-Yue; Liu, Si-Qing; Deng, Cheng-Lin; Zhang, Qiu-Yan; Zhang, Bo

    2016-10-01

    The ongoing Zika virus (ZIKV) outbreak has rapidly spread to new areas of Americas, which were the first transmissions outside its traditional endemic areas in Africa and Asia. Due to the link with newborn defects and neurological disorder, numerous infected cases throughout the world and various mosquito vectors, the virus has been considered to be an international public health emergency. In the present study, we developed a SYBR Green based one-step real-time RT-PCR assay for rapid detection of ZIKV. Our results revealed that the real-time assay is highly specific and sensitive in detection of ZIKV in cell samples. Importantly, the replication of ZIKV at different time points in infected cells could be rapidly monitored by the real-time RT-PCR assay. Specifically, the real-time RT-PCR showed acceptable performance in measurement of infectious ZIKV RNA. This assay could detect ZIKV at a titer as low as 1PFU/mL. The real-time RT-PCR assay could be a useful tool for further virology surveillance and diagnosis of ZIKV.

  7. Applications of real-time PCR in the screening of platelet concentrates for bacterial contamination.

    Science.gov (United States)

    Mohammadi, Tamimount; Savelkoul, Paul H M; Pietersz, Ruby N I; Reesink, Henk W

    2006-11-01

    Although there have been major improvements over the past few decades in detection methods for blood-borne infectious agents, platelet concentrates are still responsible for most cases of transfusion-transmitted bacterial infections. To date, real-time PCR is an indispensable tool in diagnostic laboratories to detect pathogens in a variety of biological samples. In this article, the applications of this powerful technique in the screening of platelet concentrates for bacterial contamination are discussed. Next to pathogen-specific (real-time) PCR assays, particular attention is directed to the recently developed 16S rDNA real-time PCR. This assay has been proven as a convenient way to detect bacterial contamination of platelet concentrates. The assay is sensitive and enables rapid detection of low initial numbers of bacteria in platelet concentrates. The short turnaround time of this assay allows high-throughput screening and reduction of the risk of transfusion of bacterially contaminated units. As with every method, real-time PCR has its advantages and disadvantages. These and especially limitations inherent to generation of false-positive or -negative results are emphasized. The universal nature of detection of the assay may be suitable for generalized bacterial screening of other blood components, such as red blood cells and plasma. Therefore, it is necessary to adapt and optimize detection in red blood cells and plasma with real-time PCR. Further sophistication, miniaturization and standardization of extraction and amplification methods should improve the total performance and robustness of the assay. Hence, real-time PCR is an attractive method in development as a more rapid screening test than currently used culture methods to detect bacterial contamination in blood components.

  8. Epidemiology of Plasmodium infections in Flores Island, Indonesia using real-time PCR.

    Science.gov (United States)

    Kaisar, Maria M M; Supali, Taniawati; Wiria, Aprilianto E; Hamid, Firdaus; Wammes, Linda J; Sartono, Erliyani; Luty, Adrian J F; Brienen, Eric A T; Yazdanbakhsh, Maria; van Lieshout, Lisette; Verweij, Jaco J

    2013-05-24

    DNA-based diagnostic methods have been shown to be highly sensitive and specific for the detection of malaria. An 18S-rRNA-based, real-time polymerase chain reaction (PCR) was used to determine the prevalence and intensity of Plasmodium infections on Flores Island, Indonesia. Microscopy and real-time multiplex PCR for the detection of Plasmodium species was performed on blood samples collected in a population-based study in Nangapanda Flores Island, Indonesia. A total 1,509 blood samples were analysed. Real-time PCR revealed prevalence for Plasmodium falciparum, Plasmodium vivax, and Plasmodium malariae to be 14.5%, 13.2%, and 1.9% respectively. Sub-microscopic parasitaemia were found in more than 80% of all positive cases. The prevalence of P. falciparum and P. vivax was significantly higher in subjects younger than 20 years (p ≤ 0.01). In the present study, among non-symptomatic healthy individuals, anaemia was strongly correlated with the prevalence and load of P. falciparum infections (p ≤ 0.01; p = 0.02) and with the load of P. vivax infections (p = 0.01) as detected with real-time PCR. Subjects with AB blood group tend to have a higher risk of being infected with P. falciparum and P. vivax when compared to other blood groups. The present study has shown that real-time PCR provides more insight in the epidemiology of Plasmodium infections and can be used as a monitoring tool in the battle against malaria. The unsurpassed sensitivity of real-time PCR reveals that sub microscopic infections are common in this area, which are likely to play an important role in transmission and control. Trials number ISRCTN83830814.

  9. Development of a real-time PCR method for Thalassiosira rotula rapid detection

    Institute of Scientific and Technical Information of China (English)

    HE Shanying; YU Zhigang; MI Tiezhu

    2007-01-01

    Gene specific primers and DNA probe were designed based on the sequence of 18S rDNA cloned from the red tide alga Thalassiosira rotula. A real-time fluorescent quantitative PCR (RFQ - PCR) method was developed for quantitative detection of T. rotula. The RFQ - PCR assay data showed that the results obtained with the RFQ - PCR quite good agreement with those with the light microscope (LM) counting method, which suggested that the RFQ - PCR could be a useful method for red tide alga detection.

  10. Developmental stage of strongyle eggs affects the outcome variations of real-time PCR analysis

    DEFF Research Database (Denmark)

    Andersen, Ulla Vestergaard; Haakansson, I. T.; Roust, Tina

    2013-01-01

    strongyle type parasites (NC1, NC2). SYBR Green Real-Time PCRs were performed in triplicates. Results revealed a statistically significant increase in PCR yield after three days, which was statistically associated with beginning embryonation of the eggs. In conclusion, storage time and developmental stage...... of strongyle eggs are significant sources of error in studies based on quantitative real-time PCR analysis. This study suggests that for refrigerated storage of more than three days, eggs should be inactivated and preserved for further analysis....

  11. Quantitative Analysis of Epstein-Barr Virus Load by Using a Real-Time PCR Assay

    OpenAIRE

    1999-01-01

    To measure the virus load in patients with symptomatic Epstein-Barr virus (EBV) infections, we used a real-time PCR assay to quantify the amount of EBV DNA in blood. The real-time PCR assay could detect from 2 to over 107 copies of EBV DNA with a wide linear range. We estimated the virus load in peripheral blood mononuclear cells (PBMNC) from patients with symptomatic EBV infections. The mean EBV-DNA copy number in the PBMNC was 103.7 copies/μg of DNA in patients with EBV-related lymphoprolif...

  12. Comparison of Real-time PCR method and blood culture in diagnosis of septicemia

    Directory of Open Access Journals (Sweden)

    Ali Gholami

    2016-02-01

    Full Text Available Background: Bloodstream infections (BSI have a high incidence and high mortality in the worldwide. The mortality rate is variable between 20-70%. Therefore, early and timely detection of BSI agent in clinical laboratories is necessary. The aim of this study was to determine an efficient diagnostic tool to septicemia in accompany of blood culture method by Real-time PCR (using panbacterial 23S rRNA gene. Methods: This cross-sectional study was conducted in two analytical and clinical stages in Hamadan University of Medical Sciences, Iran, from October 2014 to June 2015. In analytical stage, sensitivity (by serial dilution from 104 to 1 CFU/ml and specificity of the primer were evaluated with the Staphylococcus aureus (as Gram positive indicator bacteria and Escherichia coli (as Gram-negative indicator bacteria, human genome (from Hella cell culture, Candida albicans yeast and Aspergillus fumigatus fungus. In clinical stage, 121 blood samples were collected from patients suspected to sepsis in intensive care unit (ICU from Hamadan University Hospitals. Finally, the results of Real-time PCR and blood culture methods were compared. Results: The Real-time PCR showed a sensitivity ranging from 2 to 10 target copies per reaction to the whole blood for Escherichia coli and Staphylococcus aureus respectively. The specificity of this method was evaluated and no false positive amplification was identified. 57.85% (70 cases of the samples were positive by Real-time PCR and 13.22% (16 cases of the samples were positive by blood culture. However, none of the cases that were positive by blood culture were negative in Real-time PCR. As well as, 44.62% (54 cases of cases were positive by Real-time PCR but blood culture showed no bacteria in the samples, and 42.15% (51 cases were negative by both methods. Correlation or agreement of Kappa was 0.20, that indicating poor agreement between the two methods. Conclusion: Real-time PCR is more sensitive than blood

  13. [Development of uncompetitive exogenous internal amplification control for real-time PCR based on UFA method].

    Science.gov (United States)

    Ivanov, M K; Bragin, A G; Prasolova, M A; Vedernikov, V E; Dymshits, G M

    2009-01-01

    An uncompetitive exogenous internal amplification control method (EIAC) was developed on the basis of short synthetic DNA segment, whose amplification can be detected in real time by UFA spectroscopy principle. The EIAC was shown to be useful as internal control in diagnostic test systems based on DNA or RNA detection by multiplex real-time PCR. It can be applied to assess the quality of extracted DNA or RNA, and also to detect and study the factors causing PCR inhibition and earlier plateau effect.

  14. Quantitative assay of photoinduced DNA strand breaks by real-time PCR.

    Science.gov (United States)

    Wiczk, Justyna; Westphal, Kinga; Rak, Janusz

    2016-09-05

    Real-time PCR (qPCR) - a modern methodology primarily used for studying gene expression has been employed for the quantitative assay of an important class of DNA damage - single strand breaks. These DNA lesions which may lead to highly cytotoxic double strand breaks were quantified in a model system where double stranded DNA was sensitized to UV photons by labeling with 5-bromo-2'-deoxyuridine. The amount of breaks formed due to irradiation with several doses of 320nm photons was assayed by two independent methods: LC-MS and qPCR. A very good agreement between the relative damage measured by the two completely different analytical tools proves the applicability of qPCR for the quantitative analysis of SSBs. Our results suggest that the popularity of the hitherto underestimated though accurate and site-specific technique of real-time PCR may increase in future DNA damage studies.

  15. [Detection of human enteroviruses with real-time PCR assay using TaqMan fluorescent probe].

    Science.gov (United States)

    Leś, Katarzyna; Przybylski, Maciej; Dzieciatkowski, Tomasz; Młynarczyk, Grazyna

    2010-01-01

    Infections with human enteroviruses are common worldwide and cause a wide range of signs and symptoms. Nowadays in current diagnostics procedures older virological methods, such virus isolation in a cell cultures and seroneutralisation assay, are replaced with molecular biology tests. The aim of the study was development of real-time PCR assay for detection of human adenoviruses. DNA isolated from MK2 cell line infected with nineteen different enterovirus strains was used for development of a qualitative real-time PCR assay using primers targeting a conserved region of the 5'UTR region and a specific TaqMan probe. The analytical sensitivity of real-time PCR assay was tested using serial dilutions of Coxackie A9 cDNA in range between 10 degrees and 10(-8). For comparison typical end-point detected RT-PCR for enterovirus detection with the same cDNA dilutions was made. The sensitivity of novel method was about ten thousand-fold higher than older one. The conclusion is that real-time PCR is very advisable in diagnostics of diseases caused with enteroviruses. The high level of sensitivity, specificity, accuracy, and rapidity provided by this assay are favorable for the use in the detection of enteroviral RNA in clinical specimens, especially from neuroinfections.

  16. Real-time apta-PCR for 20 000-fold improvement in detection limit.

    Science.gov (United States)

    Pinto, Alessandro; Bermudo Redondo, M Carmen; Ozalp, V Cengiz; O'Sullivan, Ciara K

    2009-05-01

    A real-time apta-PCR for the ultrasensitive detection of thrombin is reported, where the thrombin aptamer acts not only as a biomolecular recognition element, but also as a label for amplification via real-time PCR. Aptamers can be easily converted to a reporter agent for detection by real-time PCR, simply via flanking of the aptamer's recognition moiety with primer sequences. The reported technique has the advantage of the ultrasensitivity achievable with immuno-PCR, but without the complications of addition of a DNA label, and is a technique generically applicable to all aptamers. Here, we use a sandwich format, where two existing thrombin binding aptamers with distinct binding epitopes have been utilised to capture and detect thrombin in a streptavidin-coated microtiter plate. The amount of thrombin is calculated from real-time PCR analysis of eluted captured reporter aptamer. However, the technique can also be used for aptamer-antibody sandwiches, or simply with single aptamers. A greater than 20 000-fold increase in sensitivity is achieved, highlighting the potential of this approach for the detection of very low levels of target analytes. The use of the aptamer itself as the reporter molecule eliminates the necessity of laborious enzyme/DNA labelling, facilitating a significantly more straightforward assay with a vastly enhanced sensitivity.

  17. Development and application of real-time PCR for detection of subgroup J avian leukosis virus.

    Science.gov (United States)

    Qin, Liting; Gao, Yulong; Ni, Wei; Sun, Meiyu; Wang, Yongqiang; Yin, Chunhong; Qi, Xiaole; Gao, Honglei; Wang, Xiaomei

    2013-01-01

    Subgroup J avian leukosis virus (ALV-J) is an avian retrovirus that causes severe economic losses in the poultry industry. The early identification and removal of virus-shedding birds are important to reduce the spread of congenital and contact infections. In this study, a TaqMan-based real-time PCR method for the rapid detection and quantification of ALV-J with proviral DNA was developed. This method exhibited a high specificity for ALV-J. Moreover, the detection limit was as low as 10 viral DNA copies. The coefficients of variation (CVs) of both interassay and intra-assay reproducibility were less than 1%. The growth curves of ALV-J in DF-1 cells were measured by real-time PCR, yielding a trend line similar to those determined by 50% tissue culture infective dose (TCID(50)) and p27 antigen detection. Tissue samples suspected of ALV infection were evaluated using real-time PCR, virus isolation, and routine PCR, and the positivity rates were 60.1%, 41.6% and 44.5%, respectively. Our data indicated that the real-time PCR method provides a sensitive, specific, and reproducible diagnostic tool for the identification and quantification of ALV-J for clinical diagnosis and in laboratory research.

  18. Is real-time polymerase chain reaction (PCR) more useful than a conventional PCR for the clinical management of leishmaniasis?

    Science.gov (United States)

    Antinori, Spinello; Calattini, Sara; Piolini, Roberta; Longhi, Erika; Bestetti, Giovanna; Cascio, Antonio; Parravicini, Carlo; Corbellino, Mario

    2009-07-01

    It is currently unknown if the use of a real-time polymerase chain reaction (PCR) adds value to the diagnosis and follow-up prognosis of patients affected by leishmaniasis. We performed a study using a real-time PCR directed against the alpha-polymerase gene and a semiquantitative PCR that target the SSU ribosomal RNA (rRNA) gene as control for the diagnosis and quantification of parasites in patients with visceral (VL) and cutaneous (CL) leishmaniasis. Our single copy real-time PCR missed one diagnosis of VL compared with the conventional PCR, whereas both PCR methods were able to detect Leishmania parasites in CL. Under anti-leishmania treatment the kinetics of parasitemia were comparable with the two methods. The real-time PCR directed against alpha-polymerase of Leishmania despite being able to make a more accurate quantification of parasites does not add to the decision-making management compared with a semiquantitative PCR, and it is comparatively expensive.

  19. Development of a highly sensitive one-tube nested real-time PCR for detecting Mycobacterium tuberculosis.

    Science.gov (United States)

    Choi, Yeonim; Jeon, Bo-Young; Shim, Tae Sun; Jin, Hyunwoo; Cho, Sang-Nae; Lee, Hyeyoung

    2014-12-01

    Rapid, accurate detection of Mycobacterium tuberculosis is crucial in the diagnosis of tuberculosis (TB), but conventional diagnostic methods have limited sensitivity and specificity or are time consuming. A new highly sensitive nucleic acid amplification test, combined nested and real-time polymerase chain reaction (PCR) in a single tube (one-tube nested real-time PCR), was developed for detecting M. tuberculosis, which takes advantage of two PCR techniques, i.e., nested PCR and real-time PCR. One-tube nested real-time PCR was designed to have two sequential reactions with two sets of primers and dual probes for the insertion sequence (IS) 6110 sequence of M. tuberculosis in a single closed tube. The minimum limits of detection of IS6110 real-time PCR and IS6110 one-tube nested real-time PCR were 100 fg/μL and 1 fg/μL of M. tuberculosis DNA, respectively. AdvanSure TB/non-tuberculous mycobacteria (NTM) real-time PCR, IS6110 real-time PCR, and two-tube nested real-time PCR showed 100% sensitivity and 100% specificity for clinical M. tuberculosis isolates and NTM isolates. In comparison, the sensitivities of AdvanSure TB/NTM real-time PCR, single IS6110 real-time PCR, and one-tube nested real-time PCR were 91% (152/167), 94.6% (158/167), and 100% (167/167) for sputum specimens, respectively. In conclusion, IS6110 one-tube nested real-time PCR is useful for detecting M. tuberculosis due to its high sensitivity and simple manipulation.

  20. Evaluation of IFN-γ polymorphism+874 T/A in patients with recurrent tonsillitis by PCR real time mismatch amplification mutation assay (MAMA real time PCR).

    Science.gov (United States)

    Bergallo, Massimiliano; Gambarino, Stefano; Loiacono, Elisa; Vergano, Luca; Galliano, Ilaria; Montanari, Paola; Astegiano, Sara; Tavormina, Paolo; Tovo, Pier-Angelo

    2015-02-01

    Interferon gamma (IFN-γ) is an important cytokine that plays a crucial role in the balance between normal and pathological immune response. Defect of IFN-γ can give a predisposition to infectious disease, autoimmune pathologies and tumours. Different polymorphisms in this gene have been described, in particular the single nucleotide polymorphism (SNP)+874∗T/A that may affect IFN-γ gene expression. Several techniques can be used for the detection of SNPs. In this work two PCR Real Time assays were developed, an Amplification Refractory Mutation System (ARMS) and a Mismatch Amplification Mutation Assay (MAMA). Twenty-seven samples from patients (tonsillectomy) and 85 from donor's blood bank were considered. As a result, 78/85 controls (91.7%) and 25/27 patients (92.6%) were heterozygosis, considering the ARMS-PCR; 55/85 (64.7%) and 14/27 (51.9%) were heterozygosis using MAMA-PCR assay. Fourteen of 85 (16.5%) and 8/27 (29.6%) were homozygosis A, 16/85 (18.8%) and 5/27 (18.5%) presented homozygosis T, taking into account the MAMA-PCR. There are statistically difference between the two assay with p<0.0001 at Chi-square test. Our preliminary data suggest that tonsillectomy patients had a statistical trend to possess the low IFN-γ polymorphism when compared with control subject (p=0.3) but is not statistically significant. In conclusion the Real time MAMA-PCR assay has several advantages over other SNP identification techniques such as rapidity, reliability, easily to perform in one working day and applicable in clinical molecular diagnostic laboratories, although sequencing remains the gold standard.

  1. Towards a portable microchip system with integrated thermal control and polymer waveguides for real-time PCR

    DEFF Research Database (Denmark)

    Wang, Zhenyu; Sekulovic, Andrea; Kutter, Jörg Peter

    2006-01-01

    performed with a dilution series of C. jejuni DNA template (2 to 200 pg/mu l) could be quantitatively detected and compared with a conventional post-PCR analysis (DNA gel electrophoresis). The presented approach provided reliable real-time quantitative information of the PCR amplification of the targeted......A novel real-time PCR microchip platform with integrated thermal system and polymer waveguides has been developed. The integrated polymer optical system for real-time monitoring of PCR was fabricated in the same SU-8 layer as the PCR chamber, without additional masking steps. Two suitable DNA...... binding dyes, SYTOX Orange and TO-PRO-3, were selected and tested for the real-time PCR processes. As a model, cadF gene of Campylobacter jejuni has been amplified on the microchip. Using the integrated optical system of the real-time PCR microchip, the measured cycle threshold values of the real-time PCR...

  2. Real-time Fluorescence PCR Method for Detection of Burkholderia glumae from Rice

    Institute of Scientific and Technical Information of China (English)

    FANG Yuan; XU Li-hui; TIAN Wen-xiao; HUAI Yan; YU Shan-hong; LOU Miao-miao; XIE Guan-lin

    2009-01-01

    Burkholderia glumae causing seedling rot and grain rot of rice was listed as a plant quarantine disease of China in 2007. It's quite necessary to set up effective detection methods for the pathogen to manage further dispersal of this disease. The present study combined the real-time PCR method with classical PCR to increase the detecting efficiency, and to develop an accurate, rapid and sensitive method to detect the pathogen in the seed quarantine for effective management of the disease. The results showed that all the tested strains of B. glumae produced about 139 bp specific fragments by the real-time PCR and the general PCR methods, while others showed negative PCR result. The bacteria could be detected at the concentrations of 1×104 CFU/mL by general PCR method and at the concentrations below 100 CFU/mL by real-time fluorescence PCR method. B. glumae could be detected when the inoculated and healthy seeds were mixed with a proportion of 1:100.

  3. Whole blood Nested PCR and Real-time PCR amplification of Talaromyces marneffei specific DNA for diagnosis.

    Science.gov (United States)

    Lu, Sha; Li, Xiqing; Calderone, Richard; Zhang, Jing; Ma, Jianchi; Cai, Wenying; Xi, Liyan

    2016-02-01

    Talaromyces marneffei is a dimorphic pathogenic fungus, which is a life-threatening invasive mycosis in the immunocompromised host. Prompt diagnosis of T. marneffei infection remains difficult although there has been progress in attempts to expedite the diagnosis of this infection. We previously demonstrated the value of nested polymerase chain reaction (PCR) to detect T. marneffei in paraffin embedded tissue samples with high sensitivity and specificity. In this study, this assay was used to detect the DNA of T. marneffei in whole blood samples. Real-time PCR assay was also evaluated to identify T. marneffei in the same samples. Twenty out of 30 whole blood samples (67%) collected from 23 patients were found positive by using the nested PCR assay, while 23/30 (77%) samples were found positive by using the real-time PCR assay. In order to express accurately the fungal loads, we used a normalized linearized plasmid as an internal control for real-time PCR. The assay results were correlated as the initial quantity (copies/μl) with fungal burden. These data indicate that combination of nested PCR and real-time PCR assay provides an attractive alternative for identification of T. marneffei DNA in whole blood samples of HIV-infected patients.

  4. Quantification of DNA fragmentation in processed foods using real-time PCR.

    Science.gov (United States)

    Mano, Junichi; Nishitsuji, Yasuyuki; Kikuchi, Yosuke; Fukudome, Shin-Ichi; Hayashida, Takuya; Kawakami, Hiroyuki; Kurimoto, Youichi; Noguchi, Akio; Kondo, Kazunari; Teshima, Reiko; Takabatake, Reona; Kitta, Kazumi

    2017-07-01

    DNA analysis of processed foods is performed widely to detect various targets, such as genetically modified organisms (GMOs). Food processing often causes DNA fragmentation, which consequently affects the results of PCR analysis. In order to assess the effects of DNA fragmentation on the reliability of PCR analysis, we investigated a novel methodology to quantify the degree of DNA fragmentation. We designed four real-time PCR assays that amplified 18S ribosomal RNA gene sequences common to various plants at lengths of approximately 100, 200, 400, and 800 base pairs (bp). Then, we created an indicator value, "DNA fragmentation index (DFI)", which is calculated from the Cq values derived from the real-time PCR assays. Finally, we demonstrated the efficacy of this method for the quality control of GMO detection in processed foods by evaluating the relationship between the DFI and the limit of detection. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Determination of PCR efficiency in chelex-100 purified clinical samples and comparison of real-time quantitative PCR and conventional PCR for detection of Chlamydia pneumoniae

    Directory of Open Access Journals (Sweden)

    Jensen Jørgen

    2002-07-01

    Full Text Available Abstract Background Chlamydia pneumoniae infection has been detected by serological methods, but PCR is gaining more interest. A number of different PCR assays have been developed and some are used in combination with serology for diagnosis. Real-time PCR could be an attractive new PCR method; therefore it must be evaluated and compared to conventional PCR methods. Results We compared the performance of a newly developed real-time PCR with a conventional PCR method for detection of C. pneumoniae. The PCR methods were tested on reference samples containing C. pneumoniae DNA and on 136 nasopharyngeal samples from patients with a chronic cough. We found the same detection limit for the two methods and that clinical performance was equal for the real-time PCR and for the conventional PCR method, although only three samples tested positive. To investigate whether the low prevalence of C. pneumoniae among patients with a chronic cough was caused by suboptimal PCR efficiency in the samples, PCR efficiency was determined based on the real-time PCR. Seventeen of twenty randomly selected clinical samples had a similar PCR efficiency to samples containing pure genomic C. pneumoniae DNA. Conclusions These results indicate that the performance of real-time PCR is comparable to that of conventional PCR, but that needs to be confirmed further. Real-time PCR can be used to investigate the PCR efficiency which gives a rough estimate of how well the real-time PCR assay works in a specific sample type. Suboptimal PCR efficiency of PCR is not a likely explanation for the low positivity rate of C. pneumoniae in patients with a chronic cough.

  6. Detection of Campylobacter spp. in chicken fecal samples by real-time PCR

    DEFF Research Database (Denmark)

    Lund, Marianne; Nordentoft, Steen; Pedersen, Karl

    2004-01-01

    in less than 4 h, with a detection limit of 100 to 150 CFU/ml, in a fecal suspension. A bacterial internal control was added before DNA extraction to control both DNA isolation and the presence of PCR inhibitors in the samples. The assay was performed on 111 swab samples from a Danish surveillance program......A real-time PCR assay for detecting thermophilic Campylobacter spp. directly in chicken feces has been developed. DNA was isolated from fecal material by using magnetic beads followed by PCR with a prealiquoted PCR mixture, which had been stored at -18degreesC. Campylobacter could be detected...

  7. Real-time PCR and pyrosequencing for differentiation of medically relevant Bartonella species.

    Science.gov (United States)

    Buss, Sarah N; Gebhardt, Linda L; Musser, Kimberlee A

    2012-11-01

    Multiple Bartonella species cause disease in humans. Although fast and accurate species differentiation could inform effective treatment interventions, species-level diagnosis of Bartonella infections is not typical. Here we describe a real-time PCR and pyrosequencing based algorithm for rapid differentiation of at least 11 medically relevant Bartonella spp.

  8. Real-time PCR in infectious uveitis as an alternative diagnosis

    Directory of Open Access Journals (Sweden)

    Fabio Felipe dos Santos

    2011-08-01

    Full Text Available PURPOSE: Uveitis is a major visual impairment disease affecting parts or the entire uveal tract and occasionally the sclera, the cornea or the optic nerve. The disease is a major cause of ocular morbidity and blindness in immunocompetent and immunocompromised patients. In this work we analyzed the sensitivity and specificity of real-time PCR to detect the etiological agent from blood, plasma, vitreous and aqueous humor and compared with the diagnostic hypothesis. METHODS: Twenty-seven patients (13 male were studied and Real-time PCR method was used for the detection of herpes simplex virus 1 (HSV-1, herpes simplex virus 2 (HSV-2, varicella zoster virus (VZV, cytomegalovirus (CMV, Mycobacterium tuberculosis (TB and Toxoplasma gondii (Toxo in the aqueous humor as well as in the vitreous, blood and plasma. RESULTS: Our results showed the presence of Toxo, CMV, VZV or HSV-2 in 19.2% of aqueous humor samples, and in 30% of vitreous humor samples. In plasma and blood samples, only CMV was detected (11.1% and 3.7%, respectively. CONCLUSION: Real-time PCR was able to detect and to confirm diagnostic hypothesis in uveitis. Our data also confirms that vitreous humor is the best source for molecular diagnosis of infectious uveitis but indicates aqueous humor samples that are easier to obtain may also be appropriate to be tested by Real-time PCR.

  9. Processing of gene expression data generated by quantitative real-time RT-PCR.

    Science.gov (United States)

    Muller, Patrick Y; Janovjak, Harald; Miserez, André R; Dobbie, Zuzana

    2002-06-01

    Quantitative real-time PCR represents a highly sensitive and powerful technique for the quantitation of nucleic acids. It has a tremendous potential for the high-throughput analysis of gene expression in research and routine diagnostics. However, the major hurdle is not the practical performance of the experiments themselves but rather the efficient evaluation and the mathematical and statistical analysis of the enormous amount of data gained by this technology, as these functions are not included in the software provided by the manufacturers of the detection systems. In this work, we focus on the mathematical evaluation and analysis of the data generated by quantitative real-time PCR, the calculation of the final results, the propagation of experimental variation of the measured values to the final results, and the statistical analysis. We developed a Microsoft Excel-based software application coded in Visual Basic for Applications, called Q-Gene, which addresses these points. Q-Gene manages and expedites the planning, performance, and evaluation of quantitative real-time PCR experiments, as well as the mathematical and statistical analysis, storage, and graphical presentation of the data. The Q-Gene software application is a tool to cope with complex quantitative real-time PCR experiments at a high-throughput scale and considerably expedites and rationalizes the experimental setup, data analysis, and data management while ensuring highest reproducibility.

  10. Detection of shrimp-derived components in food by real-time fluorescent PCR.

    Science.gov (United States)

    Cao, Jijuan; Yu, Bing; Ma, Lidan; Zheng, Qiuyue; Zhao, Xin; Xu, Junyi

    2011-10-01

    Crustaceans such as shrimp and crabs and their products are important allergens in food, and allergic reactions due to the consumption of shrimp and crabs are frequently reported. However, the chemical properties of shrimp-derived allergens, except for Pen a I, are still unclear. Therefore, it is important to establish a more sensitive and specific method for detecting the composition of foods containing shrimp. In the present study, we developed a real-time fluorescent PCR to identify the specific shrimp-derived components in food. The primers and TaqMan probes for real-time fluorescent PCR were designed based on 16S rRNA genes through comparing a large number of nucleic acid sequences from different species of shrimp that have been published by the National Center for Biotechnology Information. In total, 56 kinds of samples, including different kinds of shrimp, crab, fish, shellfish, and octopus, were subjected to detection by real-time PCR. The results indicated that real-time fluorescent PCR could successfully identify the shrimp-derived components. In order to explore the effect of food processing on detection sensitivity, fish powder containing shrimp powder was treated by heating at 133°C for 30 min. The limit of detection of shrimp-derived components in fish powder was 0.05% (wt/wt).

  11. Estimating marginal properties of quantitative real-time PCR data using nonlinear mixed models

    DEFF Research Database (Denmark)

    Gerhard, Daniel; Bremer, Melanie; Ritz, Christian

    2014-01-01

    A unified modeling framework based on a set of nonlinear mixed models is proposed for flexible modeling of gene expression in real-time PCR experiments. Focus is on estimating the marginal or population-based derived parameters: cycle thresholds and ΔΔc(t), but retaining the conditional mixed mod...

  12. REAL-TIME PCR DETECTION OF LISTERIA MONOCYTOGENES IN FOOD SAMPLES OF ANIMAL ORIGIN

    Directory of Open Access Journals (Sweden)

    Jaroslav Pochop

    2013-02-01

    Full Text Available The aim of this study was to follow the contamination of food with Listeria monocytogenes by using Step One real time polymerase chain reaction (PCR. We used the PrepSEQ Rapid Spin Sample Preparation Kit for isolation of DNA and SensiFAST SYBR Hi-ROX Kit for the real-time PCR performance. In 24 samples of food of animal origin without incubation were detected strains of Listeria monocytogenes in 15 samples (swabs. Nine samples were negative. Our results indicated that the real-time PCR assay developed in this study could sensitively detect Listeria monocytogenes in food of animal origin without incubation. This could prevent infection caused by Listeria monocytogenes, and also could benefit food manufacturing companies by extending their product’s shelf-life as well as saving the cost of warehousing their food products while awaiting pathogen testing results. The rapid real-time PCR-based method performed very well compared to the conventional method. It is a fast, simple, specific and sensitive way to detect nucleic acids, which could be used in clinical diagnostic tests in the future.

  13. Increased efficacy for in-house validation of real-time PCR GMO detection methods

    NARCIS (Netherlands)

    Scholtens-Toma, I.M.J.; Kok, E.J.; Hougs, L.; Molenaar, B.; Thissen, J.T.N.M.; Voet, van der H.

    2010-01-01

    To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In

  14. Application of real-time PCR to postharvest physiology – DNA isolation

    Science.gov (United States)

    Real-time PCR technology has been widely used in the postharvest plant physiology research. One of the difficulties to isolate DNA from plant martial and pathogen cells is the presence of rigid polysaccharide cell walls and capsules, which physically protect DNA from cell lysis. Many materials requi...

  15. Development of real-time PCR for detection and quantitation of Streptococcus parauberis.

    Science.gov (United States)

    Nguyen, T L; Lim, Y J; Kim, D-H; Austin, B

    2016-01-01

    Streptococcus parauberis is an increasing threat to aquaculture of olive flounder, Paralichthys olivaceus Temminck & Schlegel, in South Korea. We developed a real-time polymerase chain reaction (PCR) method using the TaqMan probe assay to detect and quantify S. parauberis by targeting the gyrB gene sequences, which are effective for molecular analysis of the genus Streptococcus. Our real-time PCR assay is capable of detecting 10 fg of genomic DNA per reaction. The intra- and interassay coefficient of variation (CV) values ranged from 0.42-1.95%, demonstrating that the assay has good reproducibility. There was not any cross-reactivity to Streptococcus iniae or to other streptococcal/lactococcal fish pathogens, such as S. agalactiae and Lactococcus garvieae, indicating that the assay is highly specific to S. parauberis. The results of the real-time PCR assay corresponded well to those of conventional culture assays for S. parauberis from inoculated tissue homogenates (r = 0.957; P real-time PCR is a valuable tool for diagnostic quantitation of S. parauberis in clinical samples.

  16. Rapid detection of Salmonella in bovine lymph nodes using a commercial real-time PCR system

    Science.gov (United States)

    Rapid Salmonella detection is needed to help prevent the distribution of contaminated food products. Using traditional culture methods, Salmonella detection can take up to 3-5 days. Using an improved protocol and a commercial real-time PCR system, we have shortened the detection time to under 24 h...

  17. Locked nucleic acid inhibits amplification of contaminating DNA in real-time PCR

    DEFF Research Database (Denmark)

    Hummelshoj, Lone; Ryder, Lars P; Madsen, Hans O

    2005-01-01

    and real-time PCR, the addition of LNA showed blocking of the amplification of genomic XBP1 but not cDNA XBP1. To test the effect of melting temperature (Tm) on the LNA, we investigated the number of LNA nucleotides that could be replaced with DNA nucleotides and still retain the blocking activity. More...

  18. REAL-TIME PCR METHOD TO DETECT ENTEROCOCCUS FAECALIS IN WATER

    Science.gov (United States)

    A 16S rDNA real-time PCR method was developed to detect Enterococcus faecalis in water samples. The dynamic range for cell detection spanned five logs and the detection limit was determined to be 6 cfu/reaction. The assay was capable of detecting E. faecalis cells added to biof...

  19. Real-time PCR assay for rapid qualitative and quantitative detection of Entamoeba histolytica.

    Science.gov (United States)

    Orosz, Erika; Perkátai, Katalin; Kapusinszky, Beatrix; Farkas, Agnes; Kucsera, István

    2012-12-01

    Simple real-time PCR assay with one set of primer and probe for rapid, sensitive qualitative and quantitative detection of Entamoeba histolytica has been used. Consensus sequences were used to amplify a species-specific region of the 16S rRNA gene, and fluorescence resonance energy transfer hybridization probes were used for detection in a LightCycler platform (Roche). The anchor probe sequence was designed to be a perfect match for the 16S rRNA gene of Entamoeba species, while the acceptor probe sequence was designed for Entamoeba histolytica, which allowed differentiation. The performed characteristics of the real-time PCR assay were compared with ELISA antigen and microscopical detection from 77 samples of individuals with suspected clinical diagnosis of imported E. histolytica infection. Stool and liver abscess pus samples were examined with analytical sensitivity of 5 parasites per PCR reaction. The melting curve means Tms (standard deviation) in clinical isolates were 54°C. The real-time assay was 100% sensitive and specific for differentiation of Entamoeba histolytica, compared with conventional ELISA or microscopy. This real-time PCR assay with melting curve analysis is rapid, and specific for the detection and differentiation of Entamoeba histolytica. The suitability for routine use of this assay in clinical diagnostic laboratories is discussed.

  20. Real time quantitative amplification detection on a microarray: towards high multiplex quantitative PCR.

    NARCIS (Netherlands)

    Pierik, A.; Moamfa, M; van Zelst, M.; Clout, D.; Stapert, H.; Dijksman, Johan Frederik; Broer, D.; Wimberger-Friedl, R.

    2012-01-01

    Quantitative real-time polymerase chain reaction (qrtPCR) is widely used as a research and diagnostic tool. Notwithstanding its many powerful features, the method is limited in the degree of multiplexing to about 6 due to spectral overlap of the available fluorophores. A new method is presented that

  1. Real-time PCR detection of Campylobacter spp.: A comparison toclassic culturing and enrichment

    NARCIS (Netherlands)

    Boer, P. de; Rahaoui, H.; Leer, R.J.; Montijn, R.C.; Vossen, J.M.B.M. van der

    2015-01-01

    The major disadvantage of the current gold standard for detection of the food pathogen Campylobacter, i.e. culturing, is the lengthy procedure. In this study we assessed the use of real-time PCR for detection of Campylobacter. To this end, 926 poultry samples, taken from transport containers and

  2. Protein Analysis Using Real-Time PCR Instrumentation: Incorporation in an Integrated, Inquiry-Based Project

    Science.gov (United States)

    Southard, Jonathan N.

    2014-01-01

    Instrumentation for real-time PCR is used primarily for amplification and quantitation of nucleic acids. The capability to measure fluorescence while controlling temperature in multiple samples can also be applied to the analysis of proteins. Conformational stability and changes in stability due to ligand binding are easily assessed. Protein…

  3. Comparison of real-time PCR protocols for differential laboratory diagnosis of amebiasis.

    Science.gov (United States)

    Qvarnstrom, Yvonne; James, Cleve; Xayavong, Maniphet; Holloway, Brian P; Visvesvara, Govinda S; Sriram, Rama; da Silva, Alexandre J

    2005-11-01

    Specific identification of Entamoeba spp. in clinical specimens is an important confirmatory diagnostic step in the management of patients who may be infected with Entamoeba histolytica, the species that causes clinical amebiasis. Distinct real-time PCR protocols have recently been published for identification of E. histolytica and differentiation from the morphologically identical nonpathogenic Entamoeba dispar. In this study, we compared three E. histolytica real-time PCR techniques published by December 2004. The limits of detection and efficiency of each real-time PCR assay were determined using DNA extracted from stool samples spiked with serially diluted cultured E. histolytica trophozoites. The ability of each assay to correctly distinguish E. histolytica from E. dispar was evaluated with DNA extracted from patients' stools and liver aspirates submitted for confirmatory diagnosis. Real-time PCR allowed quantitative analysis of the spiked stool samples, but major differences in detection limits and assay performance were observed among the evaluated tests. These results illustrate the usefulness of comparative evaluations of diagnostic assays.

  4. Real-time PCR detection of Campylobacter spp.: A comparison toclassic culturing and enrichment

    NARCIS (Netherlands)

    Boer, P. de; Rahaoui, H.; Leer, R.J.; Montijn, R.C.; Vossen, J.M.B.M. van der

    2015-01-01

    The major disadvantage of the current gold standard for detection of the food pathogen Campylobacter, i.e. culturing, is the lengthy procedure. In this study we assessed the use of real-time PCR for detection of Campylobacter. To this end, 926 poultry samples, taken from transport containers and bro

  5. Quantification of algal endosymbionts (Symbiodinium) in coral tissue using real-time PCR

    NARCIS (Netherlands)

    Mieog, J. C.; Van Oppen, M. J. H.; Berkelmans, R.; Stam, W. T.; Olsen, J. L.

    Understanding the flexibility of the endosymbioses between scleractinian corals and single-cell algae of the genus Symbiodinium will provide valuable insights into the future of coral reefs. Here, a real-time polymerase chain reaction (PCR) assay is presented to accurately determine the cell

  6. A Real-Time PCR Array for Hierarchical Identification of Francisella Isolates

    NARCIS (Netherlands)

    Svensson, Kerstin; Granberg, Malin; Karlsson, Linda; Neubauerova, Vera; Forsman, Mats; Johansson, Anders

    2009-01-01

    A robust, rapid and flexible real-time PCR assay for hierarchical genetic typing of clinical and environmental isolates of Francisella is presented. Typing markers were found by multiple genome and gene comparisons, from which 23 canonical single nucleotide polymorphisms (canSNPs) and 11 canonical i

  7. Real-time PCR validation of visually identified snapper Chrysophrys auratus (Sparidae) eggs.

    Science.gov (United States)

    Dias, P J; Wakefield, C B; Fairclough, D V; Jackson, G; Travers, M J; Snow, M

    2016-02-01

    In this study, a total of 212 eggs were visually identified as snapper Chrysophrys auratus. Real-time PCR confirmed visual identification in 69% of cases but corroboration varied widely among plankton samples. The use of molecular tools to support visual identification prior to adopting daily egg production stock assessment methods should be considered.

  8. Real-time PCR detection of Campylobacter spp.: A comparison toclassic culturing and enrichment

    NARCIS (Netherlands)

    Boer, P. de; Rahaoui, H.; Leer, R.J.; Montijn, R.C.; Vossen, J.M.B.M. van der

    2015-01-01

    The major disadvantage of the current gold standard for detection of the food pathogen Campylobacter, i.e. culturing, is the lengthy procedure. In this study we assessed the use of real-time PCR for detection of Campylobacter. To this end, 926 poultry samples, taken from transport containers and bro

  9. Quantification of algal endosymbionts (Symbiodinium) in coral tissue using real-time PCR

    NARCIS (Netherlands)

    Mieog, J. C.; Van Oppen, M. J. H.; Berkelmans, R.; Stam, W. T.; Olsen, J. L.

    2009-01-01

    Understanding the flexibility of the endosymbioses between scleractinian corals and single-cell algae of the genus Symbiodinium will provide valuable insights into the future of coral reefs. Here, a real-time polymerase chain reaction (PCR) assay is presented to accurately determine the cell densiti

  10. Protein Analysis Using Real-Time PCR Instrumentation: Incorporation in an Integrated, Inquiry-Based Project

    Science.gov (United States)

    Southard, Jonathan N.

    2014-01-01

    Instrumentation for real-time PCR is used primarily for amplification and quantitation of nucleic acids. The capability to measure fluorescence while controlling temperature in multiple samples can also be applied to the analysis of proteins. Conformational stability and changes in stability due to ligand binding are easily assessed. Protein…

  11. DEVELOPMENT OF A REAL-TIME FLUORESCENCE RESONANCE ENERGY TRANSFER PCR TO DETECT ARCOBACTER SPECIES

    Science.gov (United States)

    A real-time PCR targeting the gyrase A subunit gene outside the quinolone resistance-determining region has been developed to detect Arcobacter species. The species identification was made by probe hybridization and melting curve analysis, using Fluorescence Resonance Energy Transfer technology. D...

  12. DEVELOPMENT OF A REAL-TIME FLUORESCENCE RESONANCE ENERGY TRANSFER (FRET) PCR TO DETECT ARCOBACTER SPECIES

    Science.gov (United States)

    A real-time PCR targeting the gyrase A subunit gene outside the quinolone resistance-determining region has been developed to detect Arcobacter species. The species identification was made by probe hybridization and melting curve analysis, using the Fluorescence Resonance Energy Transfer technology...

  13. Increased efficacy for in-house validation of real-time PCR GMO detection methods

    NARCIS (Netherlands)

    Scholtens-Toma, I.M.J.; Kok, E.J.; Hougs, L.; Molenaar, B.; Thissen, J.T.N.M.; Voet, van der H.

    2010-01-01

    To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In

  14. Identifying Haemophilus haemolyticus and Haemophilus influenzae by SYBR Green real-time PCR.

    Science.gov (United States)

    Latham, Roger; Zhang, Bowen; Tristram, Stephen

    2015-05-01

    SYBR Green real time PCR assays for protein D (hpd), fuculose kinase (fucK) and [Cu, Zn]-superoxide dismutase (sodC) were designed for use in an algorithm for the identification of Haemophilus influenzae and H. haemolyticus. When tested on 127 H. influenzae and 60 H. haemolyticus all isolates were identified correctly.

  15. PCR real time assays for the early detection of BKV-DNA in immunocompromised patients.

    Science.gov (United States)

    Marinelli, Katia; Bagnarelli, Patrizia; Gaffi, Gianni; Trappolini, Silvia; Leoni, Pietro; Paggi, Alessandra Mataloni; Della Vittoria, Agnese; Scalise, Giorgio; Varaldo, Pietro Emanuele; Menzo, Stefano

    2007-07-01

    Testing for viral BKV-DNA in urine is a non-invasive early detection and monitoring tool in the diagnostic of BKV-related pathologies: quantitative analysis by Real-Time PCR can provide useful information in addition to cytologic analysis, although our study suggests that high BKV viruria is not necessarily associated with kidney or bladder damage.

  16. Development of absolute quantification method for genotype-specific Babesia microti using real-time PCR and practical experimental tips of real-time PCR.

    Science.gov (United States)

    Ohmori, Shiho; Nagano-Fujii, Motoko; Saito-Ito, Atsuko

    2016-10-01

    Babesia microti, a rodent babesia, is known as a pathogen of zoonosis, human babesiosis, is composed of several genotypes of small subunit ribosomal RNA gene (SSUrDNA) and different genotypes have been suggested to have different infectivity and pathogenicity to humans. We established a real-time PCR assay using SYBR Green I, which allows specific detection and absolute quantification for each SSUrDNA-type-B. microti of four SSUrDNA-types found in Japanese rodents even in mixed infection. In this assay, four genotype-specific primer pairs targeted on internal transcribed spacer 1 or 2 sequences were used. Primer pairs have the characteristics for a high specificity for homologous genotype DNA. The calibration curves of cycle threshold (Ct) values versus log concentrations of DNA for all four genotypes were linear over 10(7) fold range of DNA concentrations with correlation coefficient from 0.95 to 1 and sufficient amplification efficiency from 90% to 110%. The standard curves for all four genotypes were not changed even in the presence of heterologous DNA. In this paper, we introduce how to establish and perform the genotype-specific real-time PCR and our practical experimental tips to be recommended.

  17. Statistical tools for transgene copy number estimation based on real-time PCR.

    Science.gov (United States)

    Yuan, Joshua S; Burris, Jason; Stewart, Nathan R; Mentewab, Ayalew; Stewart, C Neal

    2007-11-01

    As compared with traditional transgene copy number detection technologies such as Southern blot analysis, real-time PCR provides a fast, inexpensive and high-throughput alternative. However, the real-time PCR based transgene copy number estimation tends to be ambiguous and subjective stemming from the lack of proper statistical analysis and data quality control to render a reliable estimation of copy number with a prediction value. Despite the recent progresses in statistical analysis of real-time PCR, few publications have integrated these advancements in real-time PCR based transgene copy number determination. Three experimental designs and four data quality control integrated statistical models are presented. For the first method, external calibration curves are established for the transgene based on serially-diluted templates. The Ct number from a control transgenic event and putative transgenic event are compared to derive the transgene copy number or zygosity estimation. Simple linear regression and two group T-test procedures were combined to model the data from this design. For the second experimental design, standard curves were generated for both an internal reference gene and the transgene, and the copy number of transgene was compared with that of internal reference gene. Multiple regression models and ANOVA models can be employed to analyze the data and perform quality control for this approach. In the third experimental design, transgene copy number is compared with reference gene without a standard curve, but rather, is based directly on fluorescence data. Two different multiple regression models were proposed to analyze the data based on two different approaches of amplification efficiency integration. Our results highlight the importance of proper statistical treatment and quality control integration in real-time PCR-based transgene copy number determination. These statistical methods allow the real-time PCR-based transgene copy number estimation

  18. Real-time PCR improves Helicobacter pylori detection in patients with peptic ulcer bleeding.

    Directory of Open Access Journals (Sweden)

    María José Ramírez-Lázaro

    Full Text Available BACKGROUND AND AIMS: Histological and rapid urease tests to detect H. pylori in biopsy specimens obtained during peptic ulcer bleeding episodes (PUB often produce false-negative results. We aimed to examine whether immunohistochemistry and real-time PCR can improve the sensitivity of these biopsies. PATIENTS AND METHODS: We selected 52 histology-negative formalin-fixed paraffin-embedded biopsy specimens obtained during PUB episodes. Additional tests showed 10 were true negatives and 42 were false negatives. We also selected 17 histology-positive biopsy specimens obtained during PUB to use as controls. We performed immunohistochemistry staining and real-time PCR for 16S rRNA, ureA, and 23S rRNA for H. pylori genes on all specimens. RESULTS: All controls were positive for H. pylori on all PCR assays and immunohistochemical staining. Regarding the 52 initially negative biopsies, all PCR tests were significantly more sensitive than immunohistochemical staining (p<0.01. Sensitivity and specificity were 55% and 80% for 16S rRNA PCR, 43% and 90% for ureA PCR, 41% and 80% for 23S rRNA PCR, and 7% and 100% for immunohistochemical staining, respectively. Combined analysis of PCR assays for two genes were significantly more sensitive than ureA or 23S rRNA PCR tests alone (p<0.05 and marginally better than 16S rRNA PCR alone. The best combination was 16S rRNA+ureA, with a sensitivity of 64% and a specificity of 80%. CONCLUSIONS: Real-time PCR improves the detection of H. pylori infection in histology-negative formalin-fixed paraffin-embedded biopsy samples obtained during PUB episodes. The low reported prevalence of H. pylori in PUB may be due to the failure of conventional tests to detect infection.

  19. ASSESSMENT OF DETECTION EFFICACY OF MYCOBACTERIUM TUBERCULOSIS IN SPUTUM SAMPLES BY REAL TIME PCR BASED METHOD.

    Science.gov (United States)

    Upadhyaya, S K; Dixit, S M; Shrestha, S; Dangol, S D; Pokhrel, D; Banjara, S; Shrestha, K S; Hengoju, S; Dahal, B K

    2013-07-01

    Tuberculosis (TB) is a major public health problem in Nepal and ranks as one of the most prevalent communicable diseases throughout the country. In Nepal, 45% of total population is infected with TB and 40,000 people get TB every year. Twenty thousand new sputum positive cases are seen every year and 5000-7000 people die each year from TB. Thirty sputum samples were collected from Sukraraj Tropical and Infectious Disease Hospital, Teku, Kathmandu, Nepal and the comparative study of Acid-fast Bacilli (AFB) test and Real time PCR were conducted separately with the culture test which is regarded as gold standard by WHO. Detection of Mycobacterium tuberculosis through use of Real time PCR was found to be higher as compared to AFB and culture. Real-time PCR test showed higher sensitivity (100%) and specificity (94.11%) as compared to AFB test with sensitivity of 84.61% and specificity of 88.24%. Positive predictive value was found to be 84.61% and 92.86% for AFB and Q-PCR respectively. Negative predictive value was found to be 88.24%, and for Q-PCR, it was found to be 100%. Our statistics clearly show that TB diagnosis by Q-PCR is highly efficient and reliableover conventional methods of diagnosis and here we recommend its use in the hospitals and clinics of Nepal.

  20. Detection of let-7a microRNA by real-time PCR in gastric carcinoma

    Institute of Scientific and Technical Information of China (English)

    Hong-He Zhang; Xian-Jun Wang; Guo-Xiong Li; En Yang; Ning-Min Yang

    2007-01-01

    AIM:To establish an accurate and rapid stem-loop reverse transcriptional real-time PCR (RT-PCR) method to quantify human let-7a miRNA in gastric cancer.METHODS: According to the sequence of let-7a miRNA,the stem-loop reverse transcriptional primer, the primers and quantitative MGB probes of real-time PCR were designed and synthesized. The dynamic range and the sensitivity of quantitative reverse transcriptional real-time PCR were determined. The levels of let-7a miRNA were examined in 32 gastric carcinoma samples by stem-loop RT-PCR method.RESULTS: The dynamic range and sensitivity of the let-7a miRNA quantification scheme were evaluated,the result showed the assay could precisely detect 10copies of mature let-7a miRNA in as few as 0.05 ng of total RNA of gastric mucosa. The results of specificity analysis showed no fluorescence signal occurred even though 50 ng of human genomic DNA was added to the reverse transcription (RT) reaction. The expression level of let-7a miRNA in gastric tumor tissues was significantly lower compared to normal tissues in 14 samples from 32patients.CONCLUSION: The stem-loop RT-PCR is a reliable method to detect let-7a miRNA which may play an important role in the development of gastric carcinoma.

  1. Oxygen restriction increases the infection potential of Listeria monocytogenes –verification of microarray chip data by quantitaive real-time PCR

    DEFF Research Database (Denmark)

    Bergström, Anders; Andersen, Jens Bo; Christensen, Bjarke Bak

    Listeria monocytogenes has been implicated in several food borne outbreaks as well as sporadic cases of disease during the last two decades. Increased understanding of the biology of this organism is important in the prevention of food borne listeriosis. This is highly relevant for safety...

  2. Oxygen restriction increases the infection potential of Listeria monocytogenes –verification of microarray chip data by quantitaive real-time PCR

    DEFF Research Database (Denmark)

    Bergström, Anders; Andersen, Jens Bo; Christensen, Bjarke Bak

    assessment of this organism in food. We have previously shown (Andersen et al., BMC Microbiology; 2007, 7:55) that the environmental conditions to which L. monocytogenes is exposed prior to ingestion are decisive for its in vivo infective potential in the gastrointestinal tract after passage of the gastric...... the physiological condition of these bacteria is important for food safety. The in vitro and in vivo data suggest that an oxygen-restricted L. monocytogenes cell represents a significantly higher risk than a cell grown without oxygen restriction. In order to identify transcriptional differences contributing......Listeria monocytogenes has been implicated in several food borne outbreaks as well as sporadic cases of disease during the last two decades. Increased understanding of the biology of this organism is important in the prevention of food borne listeriosis. This is highly relevant for safety...

  3. Calibration-free assays on standard real-time PCR devices

    Science.gov (United States)

    Debski, Pawel R.; Gewartowski, Kamil; Bajer, Seweryn; Garstecki, Piotr

    2017-03-01

    Quantitative Polymerase Chain Reaction (qPCR) is one of central techniques in molecular biology and important tool in medical diagnostics. While being a golden standard qPCR techniques depend on reference measurements and are susceptible to large errors caused by even small changes of reaction efficiency or conditions that are typically not marked by decreased precision. Digital PCR (dPCR) technologies should alleviate the need for calibration by providing absolute quantitation using binary (yes/no) signals from partitions provided that the basic assumption of amplification a single target molecule into a positive signal is met. Still, the access to digital techniques is limited because they require new instruments. We show an analog-digital method that can be executed on standard (real-time) qPCR devices. It benefits from real-time readout, providing calibration-free assessment. The method combines advantages of qPCR and dPCR and bypasses their drawbacks. The protocols provide for small simplified partitioning that can be fitted within standard well plate format. We demonstrate that with the use of synergistic assay design standard qPCR devices are capable of absolute quantitation when normal qPCR protocols fail to provide accurate estimates. We list practical recipes how to design assays for required parameters, and how to analyze signals to estimate concentration.

  4. Improved detection of canine Angiostrongylus vasorum infection using real-time PCR and indirect ELISA.

    Science.gov (United States)

    Jefferies, Ryan; Morgan, Eric R; Helm, Jenny; Robinson, Matthew; Shaw, Susan E

    2011-12-01

    This study reports the development of a real-time PCR assay and an indirect ELISA to improve on current detection of canine Angiostrongylus vasorum infection. A highly specific fluorescent probe-based, real-time PCR assay was developed to target the A. vasorum second internal transcribed spacer region and detected DNA in EDTA blood, lung tissue, broncho-alveolar larvage fluid, endotracheal mucus, pharyngeal swabs and faecal samples. PCR was fast (∼1 h), highly efficient when using EDTA blood samples, consistently detected a single molecule of parasite DNA and did not amplify DNA from other parasitic nematodes or definitive host species. An indirect ELISA was also developed using the soluble protein fraction from adult A. vasorum worms. Some cross-reactive antigen recognition was observed when tested against sera from dogs infected with Crenosoma vulpis (n = 8), Toxocara canis (n = 5) and Dirofilaria immitis (n = 5). This was largely overcome by setting the cut-off for a positive result at an appropriately high level. Field evaluation of the real-time PCR and ELISA was conducted by testing sera and EDTA blood from dogs with suspected A. vasorum infection (n = 148) and compared with the Baermann's larval migration test in faeces. Thirty-one dogs were positive by at least one test. Of these, 20 (65%) were detected by the Baermann method, 18 (58%) by blood PCR, 24 (77%) by ELISA and 28 (90%) by blood PCR and ELISA together. Combined testing using real-time PCR and ELISA therefore improved the detection rate of A. vasorum infection and holds promise for improved clinical diagnosis and epidemiological investigation.

  5. Detection of Balamuthia mandrillaris DNA by real-time PCR targeting the RNase P gene

    Directory of Open Access Journals (Sweden)

    Lewin Astrid

    2008-12-01

    Full Text Available Abstract Background The free-living amoeba Balamuthia mandrillaris may cause fatal encephalitis both in immunocompromised and in – apparently – immunocompetent humans and other mammalian species. Rapid, specific, sensitive, and reliable detection requiring little pathogen-specific expertise is an absolute prerequisite for a successful therapy and a welcome tool for both experimental and epidemiological research. Results A real-time polymerase chain reaction assay using TaqMan® probes (real-time PCR was established specifically targeting the RNase P gene of B. mandrillaris amoebae. The assay detected at least 2 (down to 0.5 genomes of B. mandrillaris grown in axenic culture. It did not react with DNA from closely related Acanthamoeba (3 species, nor with DNA from Toxoplasma gondii, Leishmania major, Pneumocystis murina, Mycobacterium bovis (BCG, human brain, various mouse organs, or from human and murine cell lines. The assay efficiently detected B. mandrillaris DNA in spiked cell cultures, spiked murine organ homogenates, B. mandrillaris-infected mice, and CNS tissue-DNA preparations from 2 patients with proven cerebral balamuthiasis. This novel primer set was successfully combined with a published set that targets the B. mandrillaris 18S rRNA gene in a duplex real-time PCR assay to ensure maximum specificity and as a precaution against false negative results. Conclusion A real-time PCR assay for B. mandrillaris amoebae is presented, that is highly specific, sensitive, and reliable and thus suited both for diagnosis and for research.

  6. Detection of Tumor Markers in Prostate Cancer and Comparison of Sensitivity between Real Time and Nested PCR

    OpenAIRE

    Matsuoka, Takayuki; Shigemura, Katsumi; Yamamichi, Fukashi; Fujisawa, Masato; Kawabata, Masato; Shirakawa, Toshiro

    2012-01-01

    The objective of this study is to investigate and compare the sensitivity in conventional PCR, quantitative real time PCR, nested PCR and western blots for detection of prostate cancer tumor markers using prostate cancer (PCa) cells. We performed conventional PCR, quantitative real time PCR, nested PCR, and western blots using 5 kinds of PCa cells. Prostate specific antigen (PSA), prostate specific membrane antigen (PSMA), and androgen receptor (AR) were compared for their detection sensitivi...

  7. Detection of Tumor Markers in Prostate Cancer and Comparison of Sensitivity between Real Time and Nested PCR

    OpenAIRE

    Matsuoka, Takayuki; Shigemura, Katsumi; Yamamichi, Fukashi; Fujisawa, Masato; Kawabata, Masato; Shirakawa, Toshiro

    2012-01-01

    The objective of this study is to investigate and compare the sensitivity in conventional PCR, quantitative real time PCR, nested PCR and western blots for detection of prostate cancer tumor markers using prostate cancer (PCa) cells. We performed conventional PCR, quantitative real time PCR, nested PCR, and western blots using 5 kinds of PCa cells. Prostate specific antigen (PSA), prostate specific membrane antigen (PSMA), and androgen receptor (AR) were compared for their detection sensitivi...

  8. Real-time electrochemical PCR with a DNA intercalating redox probe.

    Science.gov (United States)

    Deféver, Thibaut; Druet, Michel; Evrard, David; Marchal, Damien; Limoges, Benoit

    2011-03-01

    The proof-of-principle of a nonoptical real-time PCR method based on the electrochemical monitoring of a DNA intercalating redox probe that becomes considerably less easily electrochemically detectable once intercalated to the amplified double-stranded DNA is demonstrated. This has been made possible thanks to the finding of a redox intercalator that (i) strongly and specifically binds to the amplified double-stranded DNA, (ii) does not significantly inhibit PCR, (iii) is chemically stable under PCR cycling, and (iv) is sensitively detected by square wave voltammetry during PCR cycling. Among the different DNA intercalating redox probes that we have investigated, namely, methylene blue, Os[(bpy)(2)phen](2+), Os[(bpy)(2)DPPZ](2+), Os[(4,4'-dimethyl-bpy)(2)DPPZ](2+) and Os[(4,4'-diamino-bpy)(2)DPPZ](2+) (with bpy = 2,2'-bipyridine, phen = phenanthroline, and DPPZ = dipyrido[3,2-a:2',3'-c]phenazine), the one and only compound with which it has been possible to demonstrate the proof-of-concept is the Os[(bpy)(2)DPPZ](2+). In terms of analytical performances, the methodology described here compares well with optical-based real-time PCRs, offering finally the same advantages than the popular and routinely used SYBR Green-based real-time fluorescent PCR, but with the additional incomes of being potentially much cheaper and easier to integrate in a hand-held miniaturized device.

  9. A real-time PCR diagnostic method for detection of Naegleria fowleri.

    Science.gov (United States)

    Madarová, Lucia; Trnková, Katarína; Feiková, Sona; Klement, Cyril; Obernauerová, Margita

    2010-09-01

    Naegleria fowleri is a free-living amoeba that can cause primary amoebic meningoencephalitis (PAM). While, traditional methods for diagnosing PAM still rely on culture, more current laboratory diagnoses exist based on conventional PCR methods; however, only a few real-time PCR processes have been described as yet. Here, we describe a real-time PCR-based diagnostic method using hybridization fluorescent labelled probes, with a LightCycler instrument and accompanying software (Roche), targeting the Naegleria fowleriMp2Cl5 gene sequence. Using this method, no cross reactivity with other tested epidemiologically relevant prokaryotic and eukaryotic organisms was found. The reaction detection limit was 1 copy of the Mp2Cl5 DNA sequence. This assay could become useful in the rapid laboratory diagnostic assessment of the presence or absence of Naegleria fowleri.

  10. Rapid and economic DNA extraction from a single salmon egg for real-time PCR amplification.

    Science.gov (United States)

    Yang, Jing-Iong; Huang, Hsiao-Yun; Chou, Yii-Cheng; Chen, Chien-Cheng; Lee, Guo-Chi; Chang, Hsueh-Wei

    2011-01-01

    Salmon eggs are common in Japanese sushi and other seafood products; however, certain fish eggs are used as counterfeit salmon eggs which are found in foods and processed products. This study develops a simple, rapid, and cost-effective method for DNA extraction, filtration (FT) and dilution (DL) protocols from a single salmon egg with good DNA quality for real-time PCR amplification. The DNA amount, DNA quality, and real-time PCR performance for different dilutions and different lengths of PCR amplicons were evaluated and compared with the common Qiagen tissue kit (QTK) and Chelex-100-based (CX) protocols. The extracted DNA from a single salmon egg using the FT or DL protocol can be applied in phylogenic research, food authentication and post-marketing monitoring of genetically modified (GM) food products.

  11. Real-time PCR detection of aldoxime dehydratase genes in nitrile-degrading microorganisms.

    Science.gov (United States)

    Dooley-Cullinane, Tríona Marie; O'Reilly, Catherine; Coffey, Lee

    2017-02-01

    Aldoxime dehydratase catalyses the conversion of aldoximes to their corresponding nitriles. Utilization of the aldoxime-nitrile metabolising enzyme pathway can facilitate the move towards a greener chemistry. In this work, a real-time PCR assay was developed for the detection of aldoxime dehydratase genes in aldoxime/nitrile metabolising microorganisms which have been purified from environmental sources. A conventional PCR assay was also designed allowing gene confirmation via sequencing. Aldoxime dehydratase genes were identified in 30 microorganisms across 11 genera including some not previously shown to harbour the gene. The assay displayed a limit of detection of 1 pg/μL DNA or 7 CFU/reaction. This real-time PCR assay should prove valuable in the high-throughput screening of micro-organisms for novel aldoxime dehydratase genes towards pharmaceutical and industrial applications.

  12. Real-time quantitative PCR of microdissected paraffin-embedded breast carcinoma

    DEFF Research Database (Denmark)

    Gjerdrum, Lise Mette; Sorensen, Boe Sandahl; Kjeldsen, Eigil

    2004-01-01

    We studied the feasibility of using real-time quantitative PCR to determine HER-2 DNA amplification and mRNA expression in microdissected formalin-fixed, paraffin-embedded breast tumors and compared this with standard immunohistochemistry (IHC) and fluorescent in situ hybridization (FISH) methods....... Study cases (27 carcinomas and 3 ductal breast carcinoma in situ (DCIS) cases) showed varying Her-2 expression as determined by IHC (HercepTest). In carcinomas, there was a good correlation between HER-2 DNA amplification and strong HER-2 protein expression detected by FISH and IHC, respectively....... A single DCIS case was amplified in FISH, but not in IHC. Both HER-2 gene amplification and expression could be quantified in microdissected paraffin-embedded tumors using real-time PCR, DNA and RNA being successfully detected in 146 of 150 (97%) and 141 of 150 (94%) samples, respectively. PCR analysis...

  13. [Rapid diagnosis of psittacosis using a recently developed real-time PCR technique].

    Science.gov (United States)

    van der Bruggen, T; Kaan, J A; Heddema, E R; van Hannen, E J; de Jongh, B M

    2008-08-23

    A 37-year-old man was admitted with cough and fever. Three days after admission he was tested using a newly developed real-time PCR technique that detects the DNA of Chlamydophila psittaci. The result was positive; serological investigation was not positive until 14 days later. Psittacosis is a potentially life-threatening infectious disease. Laboratory diagnosis relies mainly on the assessment of paired sera, but this approach has obvious disadvantages in the acute setting. Routine use of the real-time PCR technique led to the rapid diagnosis of psittacosis in 6 other patients. All 7 patients recovered after antibiotic treatment. This PCR technique is a valuable adjuvant to serological testing for the rapid diagnosis of psittacosis.

  14. Protocol for Real-Time PCR Identification of Anthrax Spores from Nasal Swabs after Broth Enrichment

    Science.gov (United States)

    Oggioni, Marco R.; Meacci, Francesca; Carattoli, Alessandra; Ciervo, Alessandra; Orru, Germano; Cassone, Antonio; Pozzi, Gianni

    2002-01-01

    A mass-screening protocol for the diagnosis of anthrax from nasal swabs based on an enrichment step in liquid medium was devised. Incubation for growth was performed in autoclavable vials and racks which allow real-time PCR analysis of sterilized cultures. A dual-color PCR was set up with primers and probes for the chromosomal marker rpoB and the plasmid marker lef. Specific primer and probe sets were designed for the differentiation of Bacillus anthracis from B. cereus and for the differentiation of the Sterne vaccine strain from field isolates and the Ames strain, which was used in the recent anthrax bioterrorist attack. The present protocol thus combines the high specificity and sensitivity of real-time PCR with excellent biosafety and the low hands-on time necessary for the processing of large numbers of samples, which is extremely important during control programs involving the processing of large numbers of samples. PMID:12409358

  15. Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor.

    Science.gov (United States)

    Chen, Lin; West, Jonathan; Auroux, Pierre-Alain; Manz, Andreas; Day, Philip J R

    2007-12-01

    In this paper we present a reliable bidirectional flow DNA amplification microreactor for processing real-world genomic samples. This system shares the low-power thermal responsiveness of a continuous flow reactor with the low surface area to volume ratio character of stationary reactors for reducing surface inhibitory effects. Silanization with dimethyldichlorosilane in combination with dynamic surface passivation was used to enhance PCR compatibility and enable efficient amplification. For real-time fragment amplification monitoring we have implemented an epimodal fluorescent detection capability. The passivated bidirectional flow system was ultrasensitive, achieving an RNase P gene detection limit of 24 human genome copies with a reaction efficiency of 77%. This starts to rival the performance of a conventional real-time PCR instrument with a reaction efficiency of 93% and revitalizes flow-through PCR as a viable component of lab on a chip DNA analysis formats.

  16. Microfluidic Flow-Through Reactor with Electrochemical Sensor Array for Real-Time Pcr

    Science.gov (United States)

    Teh, Huey-Fang; Ramalingam, Naveen; Gong, Hai-Qing; Tan, Swee-Ngin

    We developed an integrated microfluidic flow-through EC-PCR (EC-PCR) microdevice for the concurrent DNA amplification, PCR products EC detection and PCR products quantification instead of the current available fluorescence detection scheme. The microfluidic flow-through EC-PCR microdevice was fabricated with the state-of-the-art microfabrication technology, by bonding a bottom glass substrate having a microelectrode array to a top glass cover having the microchannels made of PDMS material. Both the amplification of the target DNA sequence and the subsequent EC detection of the PCR products were carried out concurrently on the integrated device by real-time monitoring. The underlying principle of the microfluidic flow-through EC-PCR method was based on the changes of current signal of methylene blue (MB), which worked as an electrochemically active species DNA intercalator in the PCR mixture, during the amplification process at the extension phase. The results shown in this work indicated that the nucleic acid analysis could be performed in a fast thermal cycling and true real-time quantitative electrochemical detection. The signal variation trends of the EC detection and the fluorescence detection were the same in our verification measurements for both methods, which suggested that the EC detection method was feasible for this application.

  17. Detection and quantification of Aeromonas salmonicida in fish tissue by real-time PCR

    DEFF Research Database (Denmark)

    Bartkova, Simona; Kokotovic, Branco; Skall, H. F.

    2017-01-01

    fish by real-time PCR compared to 30% by a culture approach). Also, no real-time PCR-negative samples were found positive by culturing. A. salmonicida was detected by real-time PCR, though not by culturing, in freshwater fish showing no signs of furunculosis, indicating possible presence of carrier...... developed real-time PCR assay targeting the plasmid encoded aopP gene of A. salmonicida was, in parallel with culturing, used for the examination of five organs of 40 fish from Danish freshwater and seawater farms. Real-time PCR showed overall a higher frequency of positives than culturing (65% of positive...... fish. In seawater fish examined after an outbreak and antibiotics treatment, real-time PCR showed the presence of the bacterium in all examined organs (1-482 genomic units mg-1). With a limit of detection of 40 target copies (1-2 genomic units) per reaction, a high reproducibility and an excellent...

  18. Detection of Leishmania infantum DNA in conjunctival swabs of cats by quantitative real-time PCR.

    Science.gov (United States)

    Benassi, Julia Cristina; Benvenga, Graziella U; Ferreira, Helena Lage; Pereira, Vanessa F; Keid, Lara B; Soares, Rodrigo; Oliveira, Tricia Maria Ferreira de Sousa

    2017-06-01

    Although some studies have investigated the potential role of cats as a reservoir for Leishmania, their role in the epidemiology of visceral leishmaniasis (VL) is still poorly understood. Molecular diagnostic techniques are an important tool in VL diagnosis, and PCR shows high sensitivity and specificity for Leishmania spp. detection. Quantitative real-time PCR (qPCR) is a method that permits quantitative analysis of a large number of samples, resulting in more sensitive, accurate, and reproducible measurements of specific DNA present in the sample. This study compared real-time PCR (qPCR) and conventional PCR (cPCR) for detection of Leishmania spp. in blood and conjunctival swab (CS) samples of healthy cats from a non-endemic area in the state of São Paulo, Brazil. Of all CS samples, 1.85% (2/108) were positive for Leishmania spp. by both cPCR as qPCR (kappa index = 1), indicating excellent agreement between the two methods. The DNA from the two CS-cPCR- and CS-qPCR-positive samples was further tested with a PCR test amplifying the Leishmania spp. discriminative rRNA internal transcribed spacer 1 (ITS 1), of which one sample generated a 300-350-bp DNA fragment whose size varies according to the Leishmania species. Following sequencing, the fragment showed 100% similarity to a GenBank L. infantum sequence obtained from a cat in Italy. In conclusion, the association of qPCR and CS proved to be effective for detection of Leishmania in cats. Conjunctival swab samples were shown to be a practical and better alternative to blood samples and may be useful in the diagnosis and studies of feline leishmaniasis. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. A real-time PCR antibiogram for drug-resistant sepsis.

    Directory of Open Access Journals (Sweden)

    John R Waldeisen

    Full Text Available Current molecular diagnostic techniques for susceptibility testing of septicemia rely on genotyping for the presence of known resistance cassettes. This technique is intrinsically vulnerable due to the inability to detect newly emergent resistance genes. Traditional phenotypic susceptibility testing has always been a superior method to assay for resistance; however, relying on the multi-day growth period to determine which antimicrobial to administer jeopardizes patient survival. These factors have resulted in the widespread and deleterious use of broad-spectrum antimicrobials. The real-time PCR antibiogram, described herein, combines universal phenotypic susceptibility testing with the rapid diagnostic capabilities of PCR. We have developed a procedure that determines susceptibility by monitoring pathogenic load with the highly conserved 16S rRNA gene in blood samples exposed to different antimicrobial drugs. The optimized protocol removes heme and human background DNA from blood, which allows standard real-time PCR detection systems to be employed with high sensitivity (<100 CFU/mL. Three strains of E. coli, two of which were antimicrobial resistant, were spiked into whole blood and exposed to three different antibiotics. After real-time PCR-based determination of pathogenic load, a ΔC(t<3.0 between untreated and treated samples was found to indicate antimicrobial resistance (P<0.01. Minimum inhibitory concentration was determined for susceptible bacteria and pan-bacterial detection was demonstrated with 3 gram-negative and 2 gram-positive bacteria. Species identification was performed via analysis of the hypervariable amplicons. In summary, we have developed a universal diagnostic phenotyping technique that assays for the susceptibility of drug-resistant septicemia with the speed of PCR. The real-time PCR antibiogram achieves detection, susceptibility testing, minimum inhibitory concentration determination, and identification in less than 24

  20. A novel universal real-time PCR system using the attached universal duplex probes for quantitative analysis of nucleic acids

    Directory of Open Access Journals (Sweden)

    Wilson Zoe A

    2008-06-01

    Full Text Available Abstract Background Real-time PCR techniques are being widely used for nucleic acids analysis, but one limitation of current frequently employed real-time PCR is the high cost of the labeled probe for each target molecule. Results We describe a real-time PCR technique employing attached universal duplex probes (AUDP, which has the advantage of generating fluorescence by probe hydrolysis and strand displacement over current real-time PCR methods. AUDP involves one set of universal duplex probes in which the 5' end of the fluorescent probe (FP and a complementary quenching probe (QP lie in close proximity so that fluorescence can be quenched. The PCR primer pair with attached universal template (UT and the FP are identical to the UT sequence. We have shown that the AUDP technique can be used for detecting multiple target DNA sequences in both simplex and duplex real-time PCR assays for gene expression analysis, genotype identification, and genetically modified organism (GMO quantification with comparable sensitivity, reproducibility, and repeatability with other real-time PCR methods. Conclusion The results from GMO quantification, gene expression analysis, genotype identification, and GMO quantification using AUDP real-time PCR assays indicate that the AUDP real-time PCR technique has been successfully applied in nucleic acids analysis, and the developed AUDP real-time PCR technique will offer an alternative way for nucleic acid analysis with high efficiency, reliability, and flexibility at low cost.

  1. Legionellosis and Lung Abscesses: Contribution of Legionella Quantitative Real-Time PCR to an Adapted Followup

    Directory of Open Access Journals (Sweden)

    G. Descours

    2013-01-01

    Full Text Available We report a case of severe Legionnaires' disease (LD complicated by a lung abscess in an immunocompetent patient who required ECMO therapy and thoracic surgery. The results of repeated Legionella quantitative real-time PCR performed on both sera and respiratory samples correlated with the LD severity and the poor clinical outcome. Moreover, the PCR allowed for the detection of Legionella DNA in the lung abscess specimen, which was negative when cultured for Legionella. This case report provides a logical basis for further investigations to examine whether the Legionella quantitative PCR could improve the assessment of LD severity and constitute a prognostic marker.

  2. Rapid detection of Van genes in rectal swabs by real time PCR in Southern Brazil

    Directory of Open Access Journals (Sweden)

    Vlademir Cantarelli

    2011-10-01

    Full Text Available INTRODUCTION: Laboratory-based surveillance is an important component in the control of vancomycin resistant enterococci (VRE. METHODS: The study aimed to evaluate real-time polymerase chain reaction (RT-PCR (genes vanA-vanB for VRE detection on 115 swabs from patients included in a surveillance program. RESULTS: Sensitivity of RT-PCR was similar to primary culture (75% and 79.5%, respectively when compared to broth enriched culture, whereas specificity was 83.1%. CONCLUSIONS: RT-PCR provides same day results, however it showed low sensitivity for VRE detection.

  3. The development of a qualitative real-time RT-PCR assay for the detection of hepatitis C virus

    NARCIS (Netherlands)

    Clancy, A.; Crowley, B.; Niesters, H.; Herra, C.

    2008-01-01

    Real-time polymerase chain reaction (PCR) represents a favourable option for the detection of hepatitis C virus (HCV). A real-time reverse transcriptase PCR (RT-PCR) assay was developed as a qualitative diagnostic screening method for the detection of HCV using the ABI PRISM 7500 Sequence Detection

  4. The development of a qualitative real-time RT-PCR assay for the detection of hepatitis C virus

    NARCIS (Netherlands)

    Clancy, A.; Crowley, B.; Niesters, H.; Herra, C.

    2008-01-01

    Real-time polymerase chain reaction (PCR) represents a favourable option for the detection of hepatitis C virus (HCV). A real-time reverse transcriptase PCR (RT-PCR) assay was developed as a qualitative diagnostic screening method for the detection of HCV using the ABI PRISM 7500 Sequence Detection

  5. Development of a primer-probe energy transfer based real-time PCR for detection of Marek's disease virus

    DEFF Research Database (Denmark)

    Barfoed, Annette Malene; Østergaard, E.; Frandsen, P.L.

    2010-01-01

    A real-time PCR assay, which enables simultaneous detection and differentiation of all three serotypes of Marek's disease virus, without the need for post-PCR sequencing, has been developed. The assay is based on the primer-probe energy transfer real-time PCR, which has a relatively high tolerance...

  6. Faster quantitative real-time PCR protocols may lose sensitivity and show increased variability.

    Science.gov (United States)

    Hilscher, Chelsey; Vahrson, Wolfgang; Dittmer, Dirk P

    2005-11-27

    Quantitative real-time PCR has become the method of choice for measuring mRNA transcription. Recently, fast PCR protocols have been developed as a means to increase assay throughput. Yet it is unclear whether more rapid cycling conditions preserve the original assay performance characteristics. We compared 16 primer sets directed against Epstein-Barr virus (EBV) mRNAs using universal and fast PCR cycling conditions. These primers are of clinical relevance, since they can be used to monitor viral oncogene and drug-resistance gene expression in transplant patients and EBV-associated cancers. While none of the primers failed under fast PCR conditions, the fast PCR protocols performed worse than universal cycling conditions. Fast PCR was associated with a loss of sensitivity as well as higher variability, but not with a loss of specificity or with a higher false positive rate.

  7. Comparison of droplet digital PCR to real-time PCR for quantification of hepatitis B virus DNA.

    Science.gov (United States)

    Tang, Hui; Cai, Qingchun; Li, Hu; Hu, Peng

    2016-06-16

    Quantitative real-time PCR (qPCR) has been widely implemented for clinical hepatitis B viral load testing, but a lack of standardization and relatively poor precision hinder its usefulness. Droplet digital PCR (ddPCR) is a promising tool that offers high precision and direct quantification. In this study, we compared the ddPCR QX100 platform by Bio-Rad with the CFX384 Touch Real-Time PCR Detection System (Bio-Rad, USA) to detect serial plasmid DNA dilutions of known concentrations as well as HBV DNA extracted from patient serum samples. Both methods showed a high degree of linearity and quantitative correlation. However, ddPCR assays generated more reproducible results and detected lower copy numbers than qPCR assays. Patient sample quantifications by ddPCR and qPCR were highly agreeable based on the Bland-Altman analysis. Collectively, our findings demonstrate that ddPCR offers improved analytical sensitivity and specificity for HBV measurements and is suitable for clinical HBV detection.

  8. ABO Blood Group Genotyping by Real-time PCR in Kazakh Population

    Directory of Open Access Journals (Sweden)

    Pavel Tarlykov

    2014-12-01

    Full Text Available Introduction. ABO blood group genotyping is a new technology in hematology that helps prevent adverse transfusion reactions in patients. Identification of antigens on the surface of red blood cells is based on serology; however, genotyping employs a different strategy and is aimed directly at genes that determine the surface proteins. ABO blood group genotyping by real-time PCR has several crucial advantages over other PCR-based techniques, such as high rapidity and reliability of analysis. The purpose of this study was to examine nucleotide substitutions differences by blood types using a PCR-based method on Kazakh blood donors.Methods. The study was approved by the Ethics Committee of the National Center for Biotechnology. Venous blood samples from 369 healthy Kazakh blood donors, whose blood types had been determined by serological methods, were collected after obtaining informed consent. The phenotypes of the samples included blood group A (n = 99, B (n = 93, O (n = 132, and AB (n = 45. Genomic DNA was extracted using a salting-out method. PCR products of ABO gene were sequenced on an ABI 3730xl DNA analyzer (Applied Biosystems. The resulting nucleotide sequences were compared and aligned against reference sequence NM_020469.2. Real-time PCR analysis was performed on CFX96 Touch™ Real-Time PCR Detection System (BioRad.Results. Direct sequencing of ABO gene in 369 samples revealed that the vast majority of nucleotide substitutions that change the ABO phenotype were limited to exons 6 and 7 of the ABO gene at positions 261, 467, 657, 796, 803, 930 and 1,060. However, genotyping of only three of them (261, 796 and 803 resulted in identification of major ABO genotypes in the Kazakh population. As a result, TaqMan probe based real-time PCR assay for the specific detection of genotypes 261, 796 and 803 was developed. The assay did not take into account several other mutations that may affect the determination of blood group, because they have a

  9. Real-time PCR with internal amplification control for detecting tuberculosis: method design and validation.

    Science.gov (United States)

    Flores, E; Rodríguez, J C; Garcia-Pachón, E; Soto, J L; Ruiz, M; Escribano, I; Royo, G

    2009-08-01

    Real-time PCR has been a major development in the diagnosis of tuberculosis. However, most tests do not include an internal amplification control (IAC), which therefore limits it clinical application. In this study a new, easy to perform real-time PCR test with IAC was designed and validated in clinical samples. The primers amplified a 163-bp fragment of IS6110 of Mycobacterium tuberculosis and the IAC was designed with a fragment of a different microorganism (Chlamydia trachomatis). The interassay and intraassay variation of this test were very low (0.45-1.65% and 0.18-1.80%, respectively). The detection accuracy was validated in 50 samples (25 urine, 25 sputum) with different concentrations of M. tuberculosis, 18 clinical isolates of non-tuberculous mycobacteria and 148 samples with clinical suspicion of pulmonary tuberculosis. The specificity was 100%. The detection limit of this PCR test without IAC was approximately 15 bacteria and with IAC approximately 32 bacteria. This real-time PCR with IAC assay can improve the detection of M. tuberculosis and contribute to standardization of this diagnostic technique.

  10. Development of quantitative duplex real-time PCR method for screening analysis of genetically modified maize.

    Science.gov (United States)

    Oguchi, Taichi; Onishi, Mari; Minegishi, Yasutaka; Kurosawa, Yasunori; Kasahara, Masaki; Akiyama, Hiroshi; Teshima, Reiko; Futo, Satoshi; Furui, Satoshi; Hino, Akihiro; Kitta, Kazumi

    2009-06-01

    A duplex real-time PCR method was developed for quantitative screening analysis of GM maize. The duplex real-time PCR simultaneously detected two GM-specific segments, namely the cauliflower mosaic virus (CaMV) 35S promoter (P35S) segment and an event-specific segment for GA21 maize which does not contain P35S. Calibration was performed with a plasmid calibrant specially designed for the duplex PCR. The result of an in-house evaluation suggested that the analytical precision of the developed method was almost equivalent to those of simplex real-time PCR methods, which have been adopted as ISO standard methods for the analysis of GMOs in foodstuffs and have also been employed for the analysis of GMOs in Japan. In addition, this method will reduce both the cost and time requirement of routine GMO analysis by half. The high analytical performance demonstrated in the current study would be useful for the quantitative screening analysis of GM maize. We believe the developed method will be useful for practical screening analysis of GM maize, although interlaboratory collaborative studies should be conducted to confirm this.

  11. Livers provide a reliable matrix for real-time PCR confirmation of avian botulism.

    Science.gov (United States)

    Le Maréchal, Caroline; Ballan, Valentine; Rouxel, Sandra; Bayon-Auboyer, Marie-Hélène; Baudouard, Marie-Agnès; Morvan, Hervé; Houard, Emmanuelle; Poëzevara, Typhaine; Souillard, Rozenn; Woudstra, Cédric; Le Bouquin, Sophie; Fach, Patrick; Chemaly, Marianne

    2016-04-01

    Diagnosis of avian botulism is based on clinical symptoms, which are indicative but not specific. Laboratory investigations are therefore required to confirm clinical suspicions and establish a definitive diagnosis. Real-time PCR methods have recently been developed for the detection of Clostridium botulinum group III producing type C, D, C/D or D/C toxins. However, no study has been conducted to determine which types of matrices should be analyzed for laboratory confirmation using this approach. This study reports on the comparison of different matrices (pooled intestinal contents, livers, spleens and cloacal swabs) for PCR detection of C. botulinum. Between 2013 and 2015, 63 avian botulism suspicions were tested and 37 were confirmed as botulism. Analysis of livers using real-time PCR after enrichment led to the confirmation of 97% of the botulism outbreaks. Using the same method, spleens led to the confirmation of 90% of botulism outbreaks, cloacal swabs of 93% and pooled intestinal contents of 46%. Liver appears to be the most reliable type of matrix for laboratory confirmation using real-time PCR analysis.

  12. Methods for optimizing DNA extraction before quantifying oral bacterial numbers by real-time PCR.

    Science.gov (United States)

    Nadkarni, Mangala A; Martin, F Elizabeth; Hunter, Neil; Jacques, Nicholas A

    2009-07-01

    Methods for the optimal extraction of genomic DNA for real-time PCR enumeration of oral bacteria using the muramidase, mutanolysin, were developed using a simple in vitro oral flora model comprised of the facultative anaerobic gram-positive bacteria, Lactobacillus acidophilus and Streptococcus mutans, the gram-positive anaerobe, Parvimonas micra, and the gram-negative anaerobes, Porphyromonas gingivalis, Prevotella melaninogenica and Fusobacterium nucleatum. Traditional, as well as more elaborate, methods of quantifying bacterial numbers, including colony counting and estimation of DNA content using 4',6-diamino-2-phenylindole were compared in order to validate the real-time PCR approach. Evidence was obtained that P. gingivalis nuclease activity adversely affected the extraction of double-stranded DNA from this bacterium either alone or when it formed part of a consortium with the other bacteria. This nuclease activity could be overcome by treatment of the bacteria with either 20 mM diethyl pyrocarbonate or 70% ethanol at 4 degrees C overnight. A final purification of the DNA to remove any potential PCR inhibitors was added to the protocol in order to accurately quantify the amount of DNA by real-time PCR and hence the number of bacteria in a sample.

  13. Determination of pig sex in meat and meat products using multiplex real time-PCR.

    Science.gov (United States)

    Abdulmawjood, A; Krischek, C; Wicke, M; Klein, G

    2012-07-01

    For specific production lines, European retail companies demand exclusively female pork meat. To control the quality of their suppliers the identification and a quantitative detection of the animal sex origin of the meat is therefore of importance for meat processors. To enable a fast and reliable detection of male pig meat, a real time-PCR-system was designed in the present study. This was based on the genes AMEL-X and AMEL-Y. The real time-PCR assay allowed the detection of male pig meat at a concentration of 1% yielding a detection probability of 100% while the detection probability investigating meat samples containing 0.1% male pig meat was 44.4%. The analytic sensitivity of this system was assessed to be PCR reaction. The assessment of the accuracy of the real time-PCR assay to correctly identify sex individuals was investigated with 62 pigs including males (n=29) and females (n=33) belonging to different breeds/lines. With the newly designed test all analysed animals were correctly sexed. No amplification was obtained with cow, goat, sheep, turkey and chicken genomic DNA. The presented assay can be used for sex diagnosis, for the detection of male pig meat and for meat quality control.

  14. Quantitation of HIV-1 RNA in breast milk by real time PCR.

    Science.gov (United States)

    Becquart, Pierre; Foulongne, Vincent; Willumsen, Juana; Rouzioux, Christine; Segondy, Michel; Van de Perre, Philippe

    2006-04-01

    HIV-1 RNA in breast milk is a strong predictor of HIV-1 transmission through breastfeeding. In the present report, breast milk samples from HIV-1 uninfected donors were spiked with dilution of quantified culture supernatant from HIV-1(NDK) infected PBMC. Two RNA extraction techniques based on silica extraction, Nuclisens (BioMerieux) and Triazol (Qiagen), two techniques based on guanidine thiocynanate/chloroforme extraction, TRIzol (Life Technologie) and Amplicor HIV-1 Monitor (Roche Diagnostic Systems), and one technique based on electrostatic adsorption on iron oxide micro beads (Promega) were compared. HIV-1 RNA was quantitated by real time PCR (LTR gene) and Amplicor HIV-1 Monitor. Combining magnetic micro beads extraction and real time PCR quantitation allowed to correctly quantify breast milk HIV-1 RNA, with a difference between the expected and measured HIV-1 RNA levels always lower than 0.3 log copies/ml. The same combination was confirmed on 25 breast milk samples from HIV-1 infected women collected in Kwazulu-Natal, South Africa, by comparing measurements with those obtained by the Amplicor HIV-1 Monitor (r(2)=0.88). Nucleic acid extraction by magnetic micro beads followed by real time PCR is a reliable, sensitive, rapid and simple procedure to quantify HIV-1 RNA in breast milk and allows for PCR inhibitors found frequently in these samples.

  15. Determination of Viable Salmonella Typhimurium Cells in Heat Treated Milk By PMA/Real-Time PCR Method

    Directory of Open Access Journals (Sweden)

    Zülal Kesmen

    2017-06-01

    Full Text Available Applying different technological processes during the production of food has a lethal effect on the bacteria but DNA of these bacterial strains may cause false positive results when detected by real time PCR technique because they preserve their existence for a certain period of time. To overcome this shortcoming of the real time PCR technique, a new method has been developed in recent years, based on the removal of dead cell DNA from the medium by treatment with Propodium Monoazide (PMA before DNA extraction. In this study, real-time PCR method was combined with PMA application for the detection of live cells of Salmonella Typhimurium in heat treated milk samples. For this purpose, milk samples inoculated with S. Tyhimurium were heat treated at different temperatures (60, 65, 70 and 75°C and times (15, 60, 300, 900 sec and number of live bacteria was determined comparatively by direct real-time PCR, PMA/real-time PCR and conventional cultural method. As a result, unlike the direct real time PCR technique, PMA/real-time PCR method prevents to a certain extent of false positive results from dead cells at all tested temperatures and times but higher results were obtained from PMA/real-time PCR method when compared to conventional cultural results. Therefore, further studies should be carried out to optimize the conditions of the PMA application in order to eliminate the high positive results detected by the PMA / real-time PCR method

  16. Evaluation of real-time PCR of patient pleural effusion for diagnosis of tuberculosis

    Directory of Open Access Journals (Sweden)

    Zaha Arnaldo

    2011-08-01

    Full Text Available Abstract Background Pleural tuberculosis (TB diagnosis often requires invasive procedures such as pleural biopsy. The aim of this study was to evaluate the role of real-time polymerase chain reaction (PCR for the IS6110 sequence of M. tuberculosis in pleural fluid specimens as a rapid and non-invasive test for pleural TB diagnosis. Findings For this cross-sectional study, 150 consecutive patients with pleural effusion diagnosed by chest radiography, who were referred for diagnostic thoracocentesis and pleural biopsy and met eligibility criteria, had a pleural fluid specimen submitted for real-time PCR testing. Overall, 98 patients had pleural TB and 52 had pleural effusion secondary to other disease. TB diagnosis was obtained using acid-fast bacilli (AFB smear or culture for mycobacteria and/or histopathologic examination in 94 cases and by clinical findings in 4 cases. Sensitivity, specificity, positive and negative predictive values of PCR testing for pleural TB diagnosis were 42.8% (95% CI 38.4 - 44.8, 94.2% (95% CI 85.8 - 98.0, 93.3% (95% CI 83.6 - 97.7, and 48.5% (95% CI 44.2 - 50.4, respectively. The real-time PCR test improved TB detection from 30.6% to 42.9% when compared to AFB smear and culture methods performed on pleural fluid specimens, although the best sensitivity was achieved by combining the results of culture and histopathology of pleural tissue specimens. Conclusion The real-time PCR test of pleural fluid specimens is a useful and non-invasive additional assay for fast diagnosis of pleural TB.

  17. Comparison of real-time SYBR green dengue assay with real-time taqman RT-PCR dengue assay and the conventional nested PCR for diagnosis of primary and secondary dengue infection

    OpenAIRE

    Damodar Paudel; Richard Jarman; Kriengsak Limkittikul; Chonticha Klungthong; Supat Chamnanchanunt; Ananda Nisalak; Robert Gibbons; Watcharee Chokejindachai

    2011-01-01

    Background : Dengue fever and dengue hemorrhagic fever are caused by dengue virus. Dengue infection remains a burning problem of many countries. To diagnose acute dengue in the early phase we improve the low cost, rapid SYBR green real time assay and compared the sensitivity and specificity with real time Taqman® assay and conventional nested PCR assay. Aims: To develop low cost, rapid and reliable real time SYBR green diagnostic dengue assay and compare with Taqman real-time assay and conven...

  18. Use of TaqMan® real-time PCR for rapid detection of Salmonella enterica serovar Typhi.

    Science.gov (United States)

    Ranjbar, Reza; Naghoni, Ali; Farshad, Shohreh; Lashini, Hadi; Najafi, Ali; Sadeghifard, Nourkhoda; Mammina, Caterina

    2014-06-01

    We evaluated the performances of a newly designed real-time polymerase chain reaction (PCR) assay using TaqMan® probes to detect Salmonella Typhi. TaqMan® real-time PCR assays were performed by designed primers and probe based on the staG gene for detecting S. Typhi. The specificity of the assay was evaluated on 15 Salmonella serovars. The analytical specificity was evaluated on 20 non-Salmonella microorganisms. The analytical sensitivity was assessed using decreasing DNA quantities of S. Typhi ATCC 19430. Finally the detection capability of the TaqMan® real-time PCR assay on isolates recovered from patients with Salmonella infections was compared to the conventional PCR assay. Only S. Typhi strain had positive results when subjected to the assay using Typhi-specific real-time PCR. No amplification products were observed in real-time PCR with any of the non-Salmonella microorganisms tested. The TaqMan® real-time PCR was more sensitive than the conventional PCR. In conclusion, we found that the easy-to-use real-time PCR assays were faster than conventional PCR systems. The staG-based TaqMan® real-time PCR assay showed to be specific and sensitive method for the safe and rapid detection of the S. Typhi.

  19. Gastric Juice-Based Real-Time PCR for Tailored Helicobacter Pylori Treatment: A Practical Approach.

    Science.gov (United States)

    Peng, Xianhui; Song, Zhiqiang; He, Lihua; Lin, Sanren; Gong, Yanan; Sun, Lu; Zhao, Fei; Gu, Yixin; You, Yuanhai; Zhou, Liya; Zhang, Jianzhong

    2017-01-01

    A gastric juice-based real-time polymerase chain reaction (PCR) assay was established to identify Helicobacter pylori infection, clarithromycin susceptibility and human CYP2C19 genotypes and to guide the choice of proton pump inhibitor (PPI), clarithromycin and amoxicillin treatment for tailored H. pylori eradication therapy. From January 2013 to November 2014, 178 consecutive dyspeptic patients were enrolled for collection of gastric biopsy samples and gastric juice by endoscopy at the Peking University Third Hospital; 105 and 73 H. pylori-positive and -negative patients, respectively, were included in this study. H. pylori infection was defined as samples with both a strongly positive rapid urease test (RUT) and positive H. pylori histology. A series of primers and probes were distributed into four reactions for identifying the H. pylori cagH gene coupled with an internal control (Rnase P gene), A2142G and A2143G mutants of the H. pylori 23S rRNA gene, and single-nucleotide polymorphisms (SNPs) G681A of CYP2C19*2 and G636A of CYP2C19*3. The E-test and DNA sequencing were used to evaluate the H. pylori clarithromycin susceptibility phenotype and genotype. The SNPs CYP2C19*2 and CYP2C19*3 were also evaluated by nucleotide sequencing. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of this gastric juice-based real-time PCR assay were evaluated by comparing with the same measures obtained through gastric biopsy-based PCR and culture. The H. pylori diagnostic sensitivities of the culture, PCR, and gastric biopsy- and gastric juice-based real-time PCR assays were 90.48% (95/105), 92.38% (97/105), 97.14% (102/105) and 100% (105/105), respectively; the specificities of the above methods were all 100%. Higher false-negative rates were found among the gastric biopsy samples assessed by culture (10.48%, 11/105), PCR (7.62%, 8/105) and real-time PCR (2.86%, 3/105) than in gastric juice by real-time PCR. Regarding

  20. Design of primers and probes for quantitative real-time PCR methods.

    Science.gov (United States)

    Rodríguez, Alicia; Rodríguez, Mar; Córdoba, Juan J; Andrade, María J

    2015-01-01

    Design of primers and probes is one of the most crucial factors affecting the success and quality of quantitative real-time PCR (qPCR) analyses, since an accurate and reliable quantification depends on using efficient primers and probes. Design of primers and probes should meet several criteria to find potential primers and probes for specific qPCR assays. The formation of primer-dimers and other non-specific products should be avoided or reduced. This factor is especially important when designing primers for SYBR(®) Green protocols but also in designing probes to ensure specificity of the developed qPCR protocol. To design primers and probes for qPCR, multiple software programs and websites are available being numerous of them free. These tools often consider the default requirements for primers and probes, although new research advances in primer and probe design should be progressively added to different algorithm programs. After a proper design, a precise validation of the primers and probes is necessary. Specific consideration should be taken into account when designing primers and probes for multiplex qPCR and reverse transcription qPCR (RT-qPCR). This chapter provides guidelines for the design of suitable primers and probes and their subsequent validation through the development of singlex qPCR, multiplex qPCR, and RT-qPCR protocols.

  1. Evaluation of periodontal pathogens of the mandibular third molar pericoronitis by using real time PCR.

    Science.gov (United States)

    Sencimen, Metin; Saygun, Isil; Gulses, Aydin; Bal, Vehbi; Acikel, Cengiz H; Kubar, Ayhan

    2014-08-01

    The aim of this study was to investigate the mandibular third molar pericoronitis flora by using real-time polymerase chain reaction (PCR). The quantitative values of Aggregatibacter actinomycetemcomitans (Aa), Campylobacter rectus (Cr), Fusobacterium nucleatum (Fn), Porphyromonas gingivalis (Pg), Prevotella intermedia (Pi) and Tannerella forsythia (Tf) were evaluated in comparison with the healthy third molar flora by using real time PCR. Aa, Cr, Pg, and Pi were not statistically significant but numerically higher than the pericoronitis group. In contrast to samples from control subjects, statistically significant higher numbers of Tf were detected in samples from pericoronitis patients. The study revealed the strong relation between risk of pericoronitis and the presence of Tf. Individuals who have Tf in their samples present with an almost eight times relative risk of pericoronitis as the individuals with an absence of Tf in their samples. Tf plays an important role in the development of clinical symptoms related to pericoronitis. © 2014 FDI World Dental Federation.

  2. Quantification of mRNA Levels Using Real-Time Polymerase Chain Reaction (PCR).

    Science.gov (United States)

    Li, Yiyi; Wang, Kai; Chen, Longhua; Zhu, Xiaoxia; Zhou, Jie

    2016-01-01

    Real-time quantitative reverse transcription PCR technique has advanced greatly over the past 20 years. Messenger RNA (mRNA) levels in cells or tissues can be quantified by this approach. It is well known that changes in mRNA expression in disease, and correlation of mRNA expression profiles with clinical parameters, serve as clinically relevant biomarkers. Hence, accurate determination of the mRNA levels is critically important in describing the biological, pathological, and clinical roles of genes in health and disease. This chapter describes a real-time PCR approach to detect and quantify mRNA expression levels, which can be used for both laboratorial and clinical studies in breast cancer research.

  3. Sampling methods for rumen microbial counts by Real-Time PCR techniques

    Directory of Open Access Journals (Sweden)

    S. Puppo

    2010-02-01

    Full Text Available Fresh rumen samples were withdrawn from 4 cannulated buffalo females fed a fibrous diets in order to quantify bacteria concentration in the rumen by Real-Time PCR techniques. To obtain DNA of a good quality from whole rumen fluid, eight (M1-M8 different pre-filtration methods (cheese cloths, glass-fibre and nylon filter in combination with various centrifugation speeds (1000, 5000 and 14,000 rpm were tested. Genomic DNA extraction was performed either on fresh or frozen samples (-20°C. The quantitative bacteria analysis was realized according to Real-Time PCR procedure for Butyrivibrio fibrisolvens reported in literature. M5 resulted the best sampling procedure allowing to obtain a suitable genomic DNA. No differences were revealed between fresh and frozen samples.

  4. Multiplex real-time PCR for identification of canine parvovirus antigenic types.

    Science.gov (United States)

    Kaur, Gurpreet; Chandra, Mudit; Dwivedi, P N; Narang, Deepti

    2016-07-01

    Canine parvovirus (CPV) is an important disease causing gastroenteritis and/or haemorrhagic gastroenteritis in dogs. There are four antigenic types of CPV reported worldwide viz. CPV 2, CPV 2a, CPV 2b and CPV 2c. The diagnosis of CPV with the identification of the antigen type responsible remains problematic. In the present study, identification as well as antigenic typing of CPV was done using a de novo multiplex real time PCR to combat the problem of antigenic type identification. From the study it could be concluded that the here developed multiplex real time PCR assay could be used for rapid detection of CPV as well as typing of its three antigenic types.

  5. A real-time PCR for detection and quantification of Mycoplasma ovipneumoniae.

    Science.gov (United States)

    Yang, Falong; Dao, Xiaofang; Rodriguez-Palacios, Alex; Feng, Xufei; Tang, Cheng; Yang, Xiaonong; Yue, Hua

    2014-12-01

    A real-time PCR for detection and quantification of M. ovipneumoniae was developed using 9 recently sequenced M. ovipneumoniae genomes and primers targeting a putative adhesin gene p113. The assay proved to be specific and sensitive (with a detection limit of 22 genomic DNA) and could quantify M. ovipneumoniae DNA over a wide linear range, from 2.2 × 10(2) to 2.2 × 10(7) genomes.

  6. Detection of Schmallenberg virus in different Culicoides spp. by real-time RT-PCR.

    Science.gov (United States)

    De Regge, N; Deblauwe, I; De Deken, R; Vantieghem, P; Madder, M; Geysen, D; Smeets, F; Losson, B; van den Berg, T; Cay, A B

    2012-12-01

    To identify possible vectors of Schmallenberg virus (SBV), we tested pools containing heads of biting midges (Culicoides) that were caught during the summer and early autumn of 2011 at several places in Belgium by real-time RT-PCR. Pools of heads originating from following species: C. obsoletus complex, C. dewulfi and C. chiopterus were found positive, strongly indicating that these species are relevant vectors for SBV.

  7. Development of a Real-Time Fluorescence Resonance Energy Transfer PCR To Detect Arcobacter Species▿

    OpenAIRE

    Abdelbaqi, Khalil; Buissonnière, Alice; Prouzet-Mauleon, Valérie; Gresser, Jessica; Wesley, Irene; Mégraud, Francis; Ménard, Armelle

    2007-01-01

    A real-time PCR targeting the gyrase A subunit gene outside the quinolone resistance-determining region has been developed to detect Arcobacter species. The species identification was done by probe hybridization and melting curve analysis, using fluorescence resonance energy transfer technology. Discrimination between Arcobacter species was straightforward, as the corresponding melting points showed significant differences with the characteristic melting temperatures of 63.5°C, 58.4°C, 60.6°C...

  8. Comparison of droplet digital PCR with quantitative real-time PCR for determination of zygosity in transgenic maize.

    Science.gov (United States)

    Xu, Xiaoli; Peng, Cheng; Wang, Xiaofu; Chen, Xiaoyun; Wang, Qiang; Xu, Junfeng

    2016-12-01

    This study evaluated the applicability of droplet digital PCR (ddPCR) as a tool for maize zygosity determination using quantitative real-time PCR (qPCR) as a reference technology. Quantitative real-time PCR is commonly used to determine transgene copy number or GMO zygosity characterization. However, its effectiveness is based on identical reaction efficiencies for the transgene and the endogenous reference gene. Additionally, a calibrator sample should be utilized for accuracy. Droplet digital PCR is a DNA molecule counting technique that directly counts the absolute number of target and reference DNA molecules in a sample, independent of assay efficiency or external calibrators. The zygosity of the transgene can be easily determined using the ratio of the quantity of the target gene to the reference single copy endogenous gene. In this study, both the qPCR and ddPCR methods were used to determine insect-resistant transgenic maize IE034 zygosity. Both methods performed well, but the ddPCR method was more convenient because of its absolute quantification property.

  9. Quantification of llama inflammatory cytokine mRNAs by real-time RT-PCR.

    Science.gov (United States)

    Odbileg, Raadan; Konnai, Satoru; Usui, Tatsufumi; Ohashi, Kazuhiko; Onuma, Misao

    2005-02-01

    We have developed a method by which llama cytokine mRNAs can be quantified using real-time reverse transcription polymerase chain reaction (RT-PCR). Total RNA was extracted from lipopolysaccharide (LPS)-stimulated peripheral blood mononuclear cells (PBMCs) of llama, reverse transcribed to cDNA, and cytokine profiles for interleukin (IL)-1alpha, IL-1beta, IL-6 and tumor necrosis factor (TNF) alpha were quantified by real-time PCR. The expressions of mRNAs of inflammatory cytokines IL-1alpha, IL-1beta, IL-6 and TNFalpha were upregulated upon stimulation with LPS in a dose- and time-dependent manner. Incubation of PBMCs with 100 and 1,000 pg/ml of LPS for 3 to 6 hr resulted in the acceleration of the mRNA levels of inflammatory cytokines. Here, we describe a highly sensitive and reproducible method to quantify the transcription of llama cytokine mRNAs by real-time RT-PCR with the double-stranded DNA-binding dye SYBR Green I.

  10. Duplex Real-Time PCR Method for the Differentiation of Cronobacter sakazakii and Cronobacter malonaticus.

    Science.gov (United States)

    Li, Xiaofang; Cui, Jinghua; DU, Xiaoli; Cui, Zhigang; Huang, Yibing; Kan, Biao

    2017-01-01

    Cronobacter sakazakii and Cronobacter malonaticus are the most common species of Cronobacter , so it is necessary to detect the two species as soon as possible in surveillance programs. We developed a real-time PCR method for identifying C. sakazakii and C. malonaticus from the genus Cronobacter . In this study, the two pairs of primers and probes were designed, targeting 16S rRNA and fusA, respectively. The specificity of the real-time PCR assay was validated with 112 strains of Cronobacter , including 56 C. sakazakii , 32 C. malonaticus , 16 Cronobacter dublinensis , 6 Cronobacter turicensis , and 2 Cronobacter muytjensii . The results showed that C. sakazakii and C. malonaticus were all correctly identified, consistent with the results of another method by analyzing the clustering of the fusA sequence. The detection limit for pure culture was 10(2) CFU/ml and 10(3) CFU/g for artificially contaminated rehydrated powdered infant formula. Therefore, the developed real-time PCR was a rapid, sensitive, and reliable method for the identification of C. sakazakii and C. malonaticus .

  11. Evaluation of Enrichment Protocols for Bacterial Endosymbionts of Ciliates by Real-Time PCR.

    Science.gov (United States)

    Castelli, Michele; Lanzoni, Olivia; Rossi, Leonardo; Potekhin, Alexey; Schrallhammer, Martina; Petroni, Giulio

    2016-06-01

    Large-scale studies on obligate bacterial endosymbionts may frequently require preliminary purification and enrichment protocols, which are often elaborate to set up and to evaluate, especially if the host organism is a protist. The purpose of this study was to develop a real-time PCR-based strategy and employ it for assessing two of such enrichment protocols for Holospora caryophila, hosted by the ciliate Paramecium. Four SSU rRNA gene-targeted real-time PCR assays were designed, which allowed to compare the amount of H. caryophila to other organisms, namely the host, its food bacterium (Raoultella planticola), and free-living bacteria present in the culture medium. By the use of the real-time PCR assays in combination, it was possible to conclude that the "cell fractionation" protocol was quite successful in the enrichment of the symbiont, while the "Percoll gradient" protocol will need further refinements to be fully repeatable. The proposed approach has the potential to facilitate and encourage future studies on the yet underexplored field of bacterial endosymbionts of ciliates and other protists. It can also find valuable applications for experimental questions other than those tested, such as fast and precise assessment of symbiont abundance in natural populations and comparison among multiple coexisting symbionts.

  12. RT real-time PCR-based quantification of Uromyces fabae in planta.

    Science.gov (United States)

    Voegele, Ralf T; Schmid, Annette

    2011-09-01

    Quantification of obligate biotrophic parasites has been a long-standing problem in plant pathology. Many attempts have been made to determine how much of a pathogen is present in infected plant tissue. Methods of quantification included scoring disease symptoms, microscopic evaluation, determination of specific compounds like Ergosterol, and lately nucleic acid-based technologies. All of these methods have their drawbacks, and even real-time PCR may not be quantitative if for example the organism of interest has specific and differing numbers of nuclei in different infection structures. We applied reverse transcription (RT) real-time PCR to quantify Uromyces fabae within its host plant Vicia faba. We used three different genes, which have been shown to be constitutively expressed. Our analyses show an exponential increase of fungal material between 4 and 9 days post inoculation and thereafter reaching a steady state of around 45% of total RNA. We also used haustorium-specific genes to determine the amount of haustoria present at each time point. These analyses parallel the development of the whole fungus with the exception of the steady-state level, which is only around 5% of the total RNA. This indicates that RT real-time PCR is a suitable method for quantification of obligate biotrophic parasites, and also for the differentiation of developmental stages. © 2011 Federation of European Microbiological Societies. Published by Blackwell Publishing Ltd. All rights reserved.

  13. Duplex real-time PCR assay for rapid detection of ampicillin-resistant Enterococcus faecium.

    Science.gov (United States)

    Mohn, Stein Christian; Ulvik, Arve; Jureen, Roland; Willems, Rob J L; Top, Janetta; Leavis, Helen; Harthug, Stig; Langeland, Nina

    2004-02-01

    Rapid and accurate identification of carriers of resistant microorganisms is an important aspect of efficient infection control in hospitals. Traditional identification methods of antibiotic-resistant bacteria usually take at least 3 to 4 days after sampling. A duplex real-time PCR assay was developed for rapid detection of ampicillin-resistant Enterococcus faecium (ARE). Primers and probes that are used in this assay specifically detected the D-Ala-D-Ala ligase gene of E. faecium and the modified penicillin-binding protein 5 gene (pbp5) carrying the Glu-to-Val substitution at position 629 (Val-629) in a set of 129 tested E. faecium strains with known pbp5 sequence. Presence of the Val-629 in the strain set from 11 different countries was highly correlated with ampicillin resistance. In a screening of hospitalized patients, the real-time PCR assay yielded a sensitivity and a specificity for the detection of ARE colonization of 95% and 100%, respectively. The results were obtained 4 h after samples were harvested from overnight broth of rectal swab samples, identifying both species and the resistance marker mutation in pbp5. This novel assay reliably identifies ARE 2 to 3 days more quickly than traditional culture methods, thereby increasing laboratory throughput, making it useful for rectal screening of ARE. The assay demonstrates the advantages of real-time PCR for detection of nosocomial pathogens.

  14. A noninvasive, direct real-time PCR method for sex determination in multiple avian species

    Science.gov (United States)

    Brubaker, Jessica L.; Karouna-Renier, Natalie K.; Chen, Yu; Jenko, Kathryn; Sprague, Daniel T.; Henry, Paula F.P.

    2011-01-01

    Polymerase chain reaction (PCR)-based methods to determine the sex of birds are well established and have seen few modifications since they were first introduced in the 1990s. Although these methods allowed for sex determination in species that were previously difficult to analyse, they were not conducive to high-throughput analysis because of the laboriousness of DNA extraction and gel electrophoresis. We developed a high-throughput real-time PCR-based method for analysis of sex in birds, which uses noninvasive sample collection and avoids DNA extraction and gel electrophoresis.

  15. A noninvasive, direct real-time PCR method for sex determination in multiple avian species.

    Science.gov (United States)

    Brubaker, Jessica L; Karouna-Renier, Natalie K; Chen, Yu; Jenko, Kathryn; Sprague, Daniel T; Henry, Paula F P

    2011-03-01

    Polymerase chain reaction (PCR)-based methods to determine the sex of birds are well established and have seen few modifications since they were first introduced in the 1990s. Although these methods allowed for sex determination in species that were previously difficult to analyse, they were not conducive to high-throughput analysis because of the laboriousness of DNA extraction and gel electrophoresis. We developed a high-throughput real-time PCR-based method for analysis of sex in birds, which uses noninvasive sample collection and avoids DNA extraction and gel electrophoresis.

  16. Embryonation of Ostertagia ostertagi eggs affects the outcome of real-time quantitative PCR

    DEFF Research Database (Denmark)

    Drag, Markus; Höglund, Johan; Nejsum, Peter

    prior to detection and quantification by real-time quantitative polymerase chain reaction (qPCR). Fresh O. ostertagi eggs were isolated from cattle faeces and stored at 4°C or 25°C under aerobic or anaerobic conditions. Embryonation was monitored by microscopy and the ITS2 copies were determined by q...... the outcome of qPCR analysis for the quantitative determination of O. ostertagi eggs in cattle faeces. Cold storage at 4°C for up to 3 days or anaerobicvacuum packing at 25°C for up to 336 h will entail no undesirable effects on ITS2 copies....

  17. Embryonation of Ostertagia ostertagi eggs affects the outcome of real-time quantitative PCR

    DEFF Research Database (Denmark)

    Drag, Markus; Höglund, Johan; Nejsum, Peter

    prior to detection and quantification by real-time quantitative polymerase chain reaction (qPCR) . Fresh O. ostertagi eggs were isolated from cattle faeces and stored at 4°C or 25°C under aerobic or anaerobic conditions. Embryonation was monitored by microscopy and the ITS2 copies were determined by q...... the outcome of qPCR analysis for the quantitative determination of O. ostertagi eggs in cattle faeces. Cold storage at 4°C for up to 3 days or anaerobic vacuum packing at 25°C for up to 336 h will entail no undesirable effects on ITS2 copies....

  18. Comparison of real-time SYBR green dengue assay with real-time taqman RT-PCR dengue assay and the conventional nested PCR for diagnosis of primary and secondary dengue infection

    Directory of Open Access Journals (Sweden)

    Damodar Paudel

    2011-01-01

    Full Text Available Background : Dengue fever and dengue hemorrhagic fever are caused by dengue virus. Dengue infection remains a burning problem of many countries. To diagnose acute dengue in the early phase we improve the low cost, rapid SYBR green real time assay and compared the sensitivity and specificity with real time Taqman® assay and conventional nested PCR assay. Aims: To develop low cost, rapid and reliable real time SYBR green diagnostic dengue assay and compare with Taqman real-time assay and conventional nested PCR (modified Lanciotti. Materials and Methods: Eight cultured virus strains were diluted in tenth dilution down to undetectable level by the PCR to optimize the primer, temperature (annealing, and extension and to detect the limit of detection of the assay. Hundred and ninety three ELISA and PCR proved dengue clinical samples were tested with real time SYBR® Green assay, real time Taqman® assay to compare the sensitivity and specificity. Results: Sensitivity and specificity of real time SYBR® green dengue assay (84% and 66%, respectively was almost comparable to those (81% and 74% of Taqman real time PCR dengue assay. Real time SYBR® green RT-PCR was equally sensitive in primary and secondary infection while real time Taqman was less sensitive in the secondary infection. Sensitivity of real time Taqman on DENV3 (87% was equal to SYBR green real time PCR dengue assay. Conclusion: We developed low cost rapid diagnostic SYBR green dengue assay. Further study is needed to make duplex primer assay for the serotyping of dengue virus.

  19. Real-time PCR probe optimization using design of experiments approach.

    Science.gov (United States)

    Wadle, S; Lehnert, M; Rubenwolf, S; Zengerle, R; von Stetten, F

    2016-03-01

    Primer and probe sequence designs are among the most critical input factors in real-time polymerase chain reaction (PCR) assay optimization. In this study, we present the use of statistical design of experiments (DOE) approach as a general guideline for probe optimization and more specifically focus on design optimization of label-free hydrolysis probes that are designated as mediator probes (MPs), which are used in reverse transcription MP PCR (RT-MP PCR). The effect of three input factors on assay performance was investigated: distance between primer and mediator probe cleavage site; dimer stability of MP and target sequence (influenza B virus); and dimer stability of the mediator and universal reporter (UR). The results indicated that the latter dimer stability had the greatest influence on assay performance, with RT-MP PCR efficiency increased by up to 10% with changes to this input factor. With an optimal design configuration, a detection limit of 3-14 target copies/10 μl reaction could be achieved. This improved detection limit was confirmed for another UR design and for a second target sequence, human metapneumovirus, with 7-11 copies/10 μl reaction detected in an optimum case. The DOE approach for improving oligonucleotide designs for real-time PCR not only produces excellent results but may also reduce the number of experiments that need to be performed, thus reducing costs and experimental times.

  20. Detection of intestinal protozoa in paediatric patients with gastrointestinal symptoms by multiplex real-time PCR.

    Science.gov (United States)

    Maas, L; Dorigo-Zetsma, J W; de Groot, C J; Bouter, S; Plötz, F B; van Ewijk, B E

    2014-06-01

    The performance of a multiplex real-time PCR for the detection of Blastocystis, Dientamoeba fragilis, Giardia lamblia, Cryptosporidium species and Entamoeba species in faecal samples was evaluated in an observational prospective study. Paediatric patients (0-18 years) presenting with gastrointestinal symptoms and suspected of having enteroparasitic disease were included. A questionnaire on gastrointestinal symptoms and the chosen treatment was completed at the start of the study and after 6 weeks. Of 163 paediatric patients (mean age, 7.8 years), 114 (70%) had a PCR-positive faecal sample. D. fragilis was detected most frequently, in 101 patients, followed by Blastocystis in 49. In faecal samples of 47 patients, more than one protozoan was detected, mainly the combination of D. fragilis and Blastocystis. Reported gastrointestinal symptoms were abdominal pain (78%), nausea (30%), and altered bowel habits (28%). Eighty-nine of the PCR-positive patients were treated with antibiotics. A significant reduction in abdominal pain was observed both in treated and in untreated patients. This study demonstrated that multiplex real-time PCR detects a high percentage of intestinal protozoa in paediatric patients with gastrointestinal symptoms. However, interpretation and determination of the clinical relevance of a positive PCR result in this population are still difficult. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  1. Identification of lactic acid bacteria isolated from wine using real-time PCR.

    Science.gov (United States)

    Kántor, Attila; Kluz, Maciej; Puchalski, Czeslaw; Terentjeva, Margarita; Kačániová, Miroslava

    2016-01-01

    Different lactic acid bacteria strains have been shown to cause wine spoilage, including the generation of substances undesirable for the health of wine consumers. The aim of this study was to investigate the occurrence of selected species of heterofermentative lactobacilli, specifically Lactobacillus brevis, Lactobacillus hilgardii, and Lactobacillus plantarum in six different Slovak red wines following the fermentation process. In order to identify the dominant Lactobacillus strain using quantitative (real time) polymerized chain reaction (qPCR) method, pure lyophilized bacterial cultures from the Czech Collection of Microorganisms were used. Six different red wine samples following malolactic fermentation were obtained from selected wineries. After collection, the samples were subjected to a classic plate dilution method for enumeration of lactobacilli cells. Real-time PCR was performed after DNA extraction from pure bacterial strains and wine samples. We used SYBR® Green master mix reagents for measuring the fluorescence in qPCR. The number of lactobacilli ranged from 3.60 to 5.02 log CFU mL(-1). Specific lactobacilli strains were confirmed by qPCR in all wine samples. The number of lactobacilli ranged from 10(3) to 10(6) CFU mL(-1). A melting curve with different melting temperatures (T(m)) of DNA amplicons was obtained after PCR for the comparison of T(m) of control and experimental portions, revealing that the most common species in wine samples was Lactobacillus plantarum with a T(m) of 84.64°C.

  2. Analyzing the gene expression profile of pediatric acute myeloid leukemia with real-time PCR arrays

    Directory of Open Access Journals (Sweden)

    Yan-Fang Tao

    2012-09-01

    Full Text Available Abstract Background The Real-time PCR Array System is the ideal tool for analyzing the expression of a focused panel of genes. In this study, we will analyze the gene expression profile of pediatric acute myeloid leukemia with real-time PCR arrays. Methods Real-time PCR array was designed and tested firstly. Then gene expression profile of 11 pediatric AML and 10 normal controls was analyzed with real-time PCR arrays. We analyzed the expression data with MEV (Multi Experiment View cluster software. Datasets representing genes with altered expression profile derived from cluster analyses were imported into the Ingenuity Pathway Analysis Tool. Results We designed and tested 88 real-time PCR primer pairs for a quantitative gene expression analysis of key genes involved in pediatric AML. The gene expression profile of pediatric AML is significantly different from normal control; there are 19 genes up-regulated and 25 genes down-regulated in pediatric AML. To investigate possible biological interactions of differently regulated genes, datasets representing genes with altered expression profile were imported into the Ingenuity Pathway Analysis Tool. The results revealed 12 significant networks. Of these networks, Cellular Development, Cellular Growth and Proliferation, Tumor Morphology was the highest rated network with 36 focus molecules and the significance score of 41. The IPA analysis also groups the differentially expressed genes into biological mechanisms that are related to hematological disease, cell death, cell growth and hematological system development. In the top canonical pathways, p53 and Huntington’s disease signaling came out to be the top two most significant pathways with a p value of 1.5E-8 and2.95E-7, respectively. Conclusions The present study demonstrates the gene expression profile of pediatric AML is significantly different from normal control; there are 19 genes up-regulated and 25 genes down-regulated in pediatric AML. We

  3. Highly sensitive real-time PCR for specific detection and quantification of Coxiella burnetii

    Directory of Open Access Journals (Sweden)

    Linke Sonja

    2006-01-01

    Full Text Available Abstract Background Coxiella burnetii, the bacterium causing Q fever, is an obligate intracellular biosafety level 3 agent. Detection and quantification of these bacteria with conventional methods is time consuming and dangerous. During the last years, several PCR based diagnostic assays were developed to detect C. burnetii DNA in cell cultures and clinical samples. We developed and evaluated TaqMan-based real-time PCR assays that targeted the singular icd (isocitrate dehydrogenase gene and the transposase of the IS1111a element present in multiple copies in the C. burnetii genome. Results To evaluate the precision of the icd and IS1111 real-time PCR assays, we performed different PCR runs with independent DNA dilutions of the C. burnetii Nine Mile RSA493 strain. The results showed very low variability, indicating efficient reproducibility of both assays. Using probit analysis, we determined that the minimal number of genome equivalents per reaction that could be detected with a 95% probability was 10 for the icd marker and 6.5 for the IS marker. Plasmid standards with cloned icd and IS1111 fragments were used to establish standard curves which were linear over a range from 10 to 107 starting plasmid copy numbers. We were able to quantify cell numbers of a diluted, heat-inactivated Coxiella isolate with a detection limit of 17 C. burnetii particles per reaction. Real-time PCR targeting both markers was performed with DNA of 75 different C. burnetii isolates originating from all over the world. Using this approach, the number of IS1111 elements in the genome of the Nine Mile strain was determined to be 23, close to 20, the number revealed by genome sequencing. In other isolates, the number of IS1111 elements varied widely (between seven and 110 and seemed to be very high in some isolates. Conclusion We validated TaqMan-based real-time PCR assays targeting the icd and IS1111 markers of C. burnetii. The assays were shown to be specific, highly

  4. Microsatellite instability detection using BAT-25 and BAT-26 by Real Time PCR and HPLC in colorectal cancer

    Directory of Open Access Journals (Sweden)

    Marjan Rismanchi

    2014-03-01

    Conclusion: The sensitivity and specificity of real time PCR in MSI detection is the same as sequencing method and more than HPLC. BAT-26 marker is more sensitive than BAT-25 and MSI detection with Real time PCR could be considered as an accu-rate method to diagnose MSI in CRC tissues not sera.

  5. Clinical evaluation of β-tubulin real-time PCR for rapid diagnosis of dermatophytosis, a comparison with mycological methods.

    Science.gov (United States)

    Motamedi, Marjan; Mirhendi, Hossein; Zomorodian, Kamiar; Khodadadi, Hossein; Kharazi, Mahboobeh; Ghasemi, Zeinab; Shidfar, Mohammad Reza; Makimura, Koichi

    2017-10-01

    Following our previous report on evaluation of the beta tubulin real-time PCR for detection of dermatophytosis, this study aimed to compare the real-time PCR assay with conventional methods for the clinical assessment of its diagnostic performance. Samples from a total of 853 patients with suspected dermatophyte lesions were subjected to direct examination (all samples), culture (499 samples) and real-time PCR (all samples). Fungal DNA was extracted directly from clinical samples using a conical steel bullet, followed by purification with a commercial kit and subjected to the Taq-Man probe-based real-time PCR. The study showed that among the 499 specimens for which all three methods were used, 156 (31.2%), 128 (25.6%) and 205 (41.0%) were found to be positive by direct microscopy, culture and real-time PCR respectively. Real-time PCR significantly increased the detection rate of dermatophytes compared with microscopy (288 vs 229) with 87% concordance between the two methods. The sensitivity, specificity, positive predictive value, and negative predictive value of the real-time PCR was 87.5%, 85%, 66.5% and 95.2% respectively. Although real-time PCR performed better on skin than on nail samples, it should not yet fully replace conventional diagnosis. © 2017 Blackwell Verlag GmbH.

  6. [Real-time PCR kits for the detection of the African Swine Fever virus].

    Science.gov (United States)

    Latyshev, O E; Eliseeva, O V; Grebennikova, T V; Verkhovskiĭ, O A; Tsibezov, V V; Chernykh, O Iu; Dzhailidi, G A; Aliper, T I

    2014-01-01

    The results obtained using the diagnostic kit based on real-time polymerase chain reaction to detect the DNA of the African Swine Fever in the pathological material, as well as in the culture fluid, are presented. A high sensitivity and specificity for detection of the DNA in the organs and tissues of animals was shown to be useful for detection in the European Union referentiality reagent kits for DNA detection by real time PCR of ASFV. More rapid and effective method of DNA extraction using columns mini spin Quick gDNA(TM) MiniPrep was suggested and compared to the method of DNA isolation on the inorganic sorbent. High correlation of the results of the DNA detection of ASFV by real-time PCR and antigen detection results ASFV by competitive ELISA obtained with the ELISA SEROTEST/INGEZIM COMRAC PPA was demonstrated. The kit can be used in the veterinary services for effective monitoring of ASFV to contain, eliminate and prevent further spread of the disease.

  7. [Rapid detection of rotavirus in water samples using immunomagnetic separation combined with real time PCR].

    Science.gov (United States)

    Yang, Wan; He, Miao; Li, Dan; Shi, Han-Chang; Liu, Li

    2009-05-15

    A quantitative and rapid detection method for rotavirus in water samples was developed, by using immunomagnetic separation combined with reverse transcription and real time polymerase chain reaction (IMS-RT-real time PCR). Magnetic beads coated with antibodies directed against group A rotavirus were used to capture and purify the virus in water samples. The experimental results showed that IMS was optimized when 1 mL samples were supplemented with 10 microL of immunomagnetic beads, 2.5 microL of Tween 20 and incubated for 2 h. The IMS method was employed in the detection of rotavirus in seeded virus eluant such as 3% beef extract successfully and thus manifested its compatibility with established virus concentration methods. The IMS-RT-real time PCR method could yield quantitative results within about 5 h with a detection limit at 1 x 10(4) copies/mL (equivalent to 3-4 PFU/mL). The method exhibited a high level correlation (R2 = 0.9816) with cell culture assay, indicating that it could perform as well as cell culture assay does in infection tests. And the method functioned satisfactorily in seeded concentrate of secondary waste water treatment plant effluent, reclaimed water, surface water and tap water.

  8. Universal reverse-transcriptase real-time PCR for infectious hematopoietic necrosis virus (IHNV)

    Science.gov (United States)

    Purcell, Maureen K.; Thompson, Rachel L.; Garver, Kyle A.; Hawley, Laura M.; Batts, William N.; Sprague, Laura; Sampson, Corie; Winton, James R.

    2013-01-01

    Infectious hematopoietic necrosis virus (IHNV) is an acute pathogen of salmonid fishes in North America, Europe and Asia and is reportable to the World Organization for Animal Health (OIE). Phylogenetic analysis has identified 5 major virus genogroups of IHNV worldwide, designated U, M, L, E and J; multiple subtypes also exist within those genogroups. Here, we report the development and validation of a universal IHNV reverse-transcriptase real-time PCR (RT-rPCR) assay targeting the IHNV nucleocapsid (N) gene. Properties of diagnostic sensitivity (DSe) and specificity (DSp) were defined using laboratory-challenged steelhead trout Oncorhynchus mykiss, and the new assay was compared to the OIE-accepted conventional PCR test and virus isolation in cell culture. The IHNV N gene RT-rPCR had 100% DSp and DSe and a higher estimated diagnostic odds ratio (DOR) than virus culture or conventional PCR. The RT-rPCR assay was highly repeatable within a laboratory and highly reproducible between laboratories. Field testing of the assay was conducted on a random sample of juvenile steelhead collected from a hatchery raceway experiencing an IHN epizootic. The RT-rPCR detected a greater number of positive samples than cell culture and there was 40% agreement between the 2 tests. Overall, the RT-rPCR assay was highly sensitive, specific, repeatable and reproducible and is suitable for use in a diagnostic setting.

  9. Low-cost, real-time, continuous flow PCR system for pathogen detection.

    Science.gov (United States)

    Fernández-Carballo, B Leticia; McGuiness, Ian; McBeth, Christine; Kalashnikov, Maxim; Borrós, Salvador; Sharon, Andre; Sauer-Budge, Alexis F

    2016-04-01

    In this paper, we present a portable and low cost point-of-care (POC) PCR system for quantitative detection of pathogens. Our system is based on continuous flow PCR which maintains fixed temperatures zones and pushes the PCR solution between two heated areas allowing for faster heat transfer and as a result, a faster PCR. The PCR system is built around a 46.0 mm × 30.9 mm × 0.4 mm disposable thermoplastic chip. In order to make the single-use chip economically viable, it was manufactured by hot embossing and was designed to be compatible with roll-to-roll embossing for large scale production. The prototype instrumentation surrounding the chip includes two heaters, thermal sensors, and an optical system. The optical system allows for pathogen detection via real time fluorescence measurements. FAM probes were used as fluorescent reporters of the amplicons generated during the PCR. To demonstrate the function of the chip, two infectious bacteria targets were selected: Chlamydia trachomatis and Escherichia coli O157:H7. For both bacteria, the limit of detection of the system was determined, PCR efficiencies were calculated, and different flow velocities were tested. We have demonstrated successful detection for these two bacterial pathogens highlighting the versatility and broad utility of our portable, low-cost, and rapid PCR diagnostic device.

  10. Tendency for interlaboratory precision in the GMO analysis method based on real-time PCR.

    Science.gov (United States)

    Kodama, Takashi; Kurosawa, Yasunori; Kitta, Kazumi; Naito, Shigehiro

    2010-01-01

    The Horwitz curve estimates interlaboratory precision as a function only of concentration, and is frequently used as a method performance criterion in food analysis with chemical methods. The quantitative biochemical methods based on real-time PCR require an analogous criterion to progressively promote method validation. We analyzed the tendency of precision using a simplex real-time PCR technique in 53 collaborative studies of seven genetically modified (GM) crops. Reproducibility standard deviation (SR) and repeatability standard deviation (Sr) of the genetically modified organism (GMO) amount (%) was more or less independent of GM crops (i.e., maize, soybean, cotton, oilseed rape, potato, sugar beet, and rice) and evaluation procedure steps. Some studies evaluated whole steps consisting of DNA extraction and PCR quantitation, whereas others focused only on the PCR quantitation step by using DNA extraction solutions. Therefore, SR and Sr for GMO amount (%) are functions only of concentration similar to the Horwitz curve. We proposed S(R) = 0.1971C 0.8685 and S(r) = 0.1478C 0.8424, where C is the GMO amount (%). We also proposed a method performance index in GMO quantitative methods that is analogous to the Horwitz Ratio.

  11. Real-Time PCR using a PCR Microchip with Integrated Thermal System and Polymer Waveguides for the Detection of Campylobacter jejuni

    DEFF Research Database (Denmark)

    Wang, Zhenyu; Sekulovic, Andrea; Kutter, Jörg Peter

    2006-01-01

    A novel real-time PCR microchip platform with integrated thermal system and polymer waveguides has been developed. By using the integrated optical system of the real-time PCR chip, cadF – a virulence gene of Campylobacter jejuni, could specifically be detected. Two different DNA binding dyes, SYTOX...... Orange and TO-PRO-3, were added to the PCR mixture to realize the real-time PCR. The presented approach shows reliable real-time quantitative information of the PCR amplification of the targeted gene....

  12. 1,2-propanediol-trehalose mixture as a potent quantitative real-time PCR enhancer

    Directory of Open Access Journals (Sweden)

    Dráberová Lubica

    2011-04-01

    Full Text Available Abstract Background Quantitative real-time PCR (qPCR is becoming increasingly important for DNA genotyping and gene expression analysis. For continuous monitoring of the production of PCR amplicons DNA-intercalating dyes are widely used. Recently, we have introduced a new qPCR mix which showed improved amplification of medium-size genomic DNA fragments in the presence of DNA dye SYBR green I (SGI. In this study we tested whether the new PCR mix is also suitable for other DNA dyes used for qPCR and whether it can be applied for amplification of DNA fragments which are difficult to amplify. Results We found that several DNA dyes (SGI, SYTO-9, SYTO-13, SYTO-82, EvaGreen, LCGreen or ResoLight exhibited optimum qPCR performance in buffers of different salt composition. Fidelity assays demonstrated that the observed differences were not caused by changes in Taq DNA polymerase induced mutation frequencies in PCR mixes of different salt composition or containing different DNA dyes. In search for a PCR mix compatible with all the DNA dyes, and suitable for efficient amplification of difficult-to-amplify DNA templates, such as those in whole blood, of medium size and/or GC-rich, we found excellent performance of a PCR mix supplemented with 1 M 1,2-propanediol and 0.2 M trehalose (PT enhancer. These two additives together decreased DNA melting temperature and efficiently neutralized PCR inhibitors present in blood samples. They also made possible more efficient amplification of GC-rich templates than betaine and other previously described additives. Furthermore, amplification in the presence of PT enhancer increased the robustness and performance of routinely used qPCRs with short amplicons. Conclusions The combined data indicate that PCR mixes supplemented with PT enhancer are suitable for DNA amplification in the presence of various DNA dyes and for a variety of templates which otherwise can be amplified with difficulty.

  13. Use of Multiplex Real-Time PCR To Diagnose Scrub Typhus.

    Science.gov (United States)

    Tantibhedhyangkul, Wiwit; Wongsawat, Ekkarat; Silpasakorn, Saowaluk; Waywa, Duangdao; Saenyasiri, Nuttawut; Suesuay, Jintapa; Thipmontree, Wilawan; Suputtamongkol, Yupin

    2017-05-01

    Scrub typhus, caused by Orientia tsutsugamushi, is a common cause of acute undifferentiated febrile illness in the Asia-Pacific region. However, its nonspecific clinical manifestation often prevents early diagnosis. We propose the use of PCR and serologic tests as diagnostic tools. Here, we developed a multiplex real-time PCR assay using hydrolysis (TaqMan) probes targeting O. tsutsugamushi 47-kDa, groEL, and human interferon beta (IFN-β gene) genes to improve early diagnosis of scrub typhus. The amplification efficiency was higher than 94%, and the lower detection limit was 10 copies per reaction. We used a human gene as an internal DNA quality and quantity control. To determine the sensitivity of this PCR assay, we selected patients with confirmed scrub typhus who exhibited a clear 4-fold increase in the level of IgG and/or IgM. The PCR assay result was positive in 45 of 52 patients, indicating a sensitivity of 86.5% (95% confidence interval [CI]: 74.2 to 94.4). The PCR assessment was negative for all 136 non-scrub typhus patients, indicating a specificity of 100% (95% CI: 97.3 to 100). In addition, this test helped diagnose patients with inconclusive immunofluorescence assay (IFA) results and using single blood samples. In conclusion, the real-time PCR assay proposed here is sensitive and specific in diagnosing scrub typhus. Combining PCR and serologic tests will improve the diagnosis of scrub typhus among patients presenting with acute febrile illness. Copyright © 2017 American Society for Microbiology.

  14. Comparison of blood culture and multiplex real-time PCR for the diagnosis of nosocomial sepsis.

    Science.gov (United States)

    Dinç, Fatih; Akalin, Halis; Özakin, Cüneyt; Sinirtaş, Melda; Kebabçi, Nesrin; Işçimen, Remzi; Kelebek Girgin, Nermin; Kahveci, Ferda

    2016-03-01

    In many cases of suspected sepsis, causative microorganisms cannot be isolated. Multiplex real-time PCR generates results more rapidly than conventional blood culture systems. In this study, we evaluated the diagnostic performance of multiplex real-time PCR (LightCycler® SeptiFast, Roche, Mannheim, Germany), and compared with blood cultures and cultures from focus of infection in nosocomial sepsis. Seventy-eight nosocomial sepsis episodes in 67 adult patients were included in this study. The rates of microorganism detection by blood culture and PCR were 34.2% and 47.9%, respectively. Sixty-five microorganisms were detected by both methods from 78 sepsis episodes. Nineteen of these microorganisms were detected by both blood culture and PCR analysis from the same sepsis episode. There was statistically moderate concordance between the two methods (κ=0.445, Pdetected (κ=0.160, P=0.07). Comparison of the results of PCR and cultures from focus of infection revealed no significant agreement (κ=0.110, P=0.176). However, comparison of the results of PCR and blood cultures plus cultures from focus of infection (positive blood culture and/or positive culture from focus of infection) showed poor agreement (κ=0.17, P=0.026). When the blood culture was used as the gold standard, the sensitivity, specificity, positive and negative predictive value of PCR in patients with bacteremia was 80%, 69%, 57% and 87%, respectively. SeptiFast may be useful when added to blood culture in the diagnosis and management of sepsis.

  15. Chimeric External Control to Quantify Cell Free DNA in Plasma Samples by Real Time PCR

    Science.gov (United States)

    Eini, Maryam; Behzad-Behbahani, Abbas; Takhshid, Mohammad Ali; Ramezani, Amin; Rafiei Dehbidi, Gholam Reza; Okhovat, Mohammad Ali; Farhadi, Ali; Alavi, Parniyan

    2016-01-01

    Background: DNA isolation procedure can significantly influence the quantification of DNA by real time PCR specially when cell free DNA (cfDNA) is the subject. To assess the extraction efficiency, linearity of the extraction yield, presence of co-purified inhibitors and to avoid problems with fragment size relevant to cfDNA, development of appropriate External DNA Control (EDC) is challenging. Using non-human chimeric nucleotide sequences, an EDC was developed for standardization of qPCR for monitoring stability of cfDNA concentration in blood samples over time. Methods: A0 DNA fragment of 167 bp chimeric sequence of parvovirus B19 and pBHA designated as EDC fragment was designed. To determine the impact of different factors during DNA extraction processing on quantification of cfDNA, blood samples were collected from normal subjects and divided into aliquots with and without specific treatment. In time intervals, the plasma samples were isolated. The amplicon of 167 bp EDC fragment in final concentration of 1.1 pg/500 μl was added to each plasma sample and total DNA was extracted by an in house method. Relative and absolute quantification real time PCR was performed to quantify both EDC fragment and cfDNA in extracted samples. Results: Comparison of real time PCR threshold cycle (Ct) for cfDNA fragment in tubes with and without specific treatment indicated a decrease in untreated tubes. In contrast, the threshold cycle was constant for EDC fragment in treated and untreated tubes, indicating the difference in Ct values of the cfDNA is because of specific treatments that were made on them. Conclusions: Spiking of DNA fragment size relevant to cfDNA into the plasma sample can be useful to minimize the bias due to sample preparation and extraction processing. Therefore, it is highly recommended that standard external DNA control be employed for the extraction and quantification of cfDNA for accurate data analysis. PMID:27141267

  16. Real-time PCR using mycobacteriophage DNA for rapid phenotypic drug susceptibility results for Mycobacterium tuberculosis.

    Science.gov (United States)

    Pholwat, Suporn; Ehdaie, Beeta; Foongladda, Suporn; Kelly, Kimberly; Houpt, Eric

    2012-03-01

    Managing drug-resistant Mycobacterium tuberculosis requires drug susceptibility testing, yet conventional drug susceptibility testing is slow, and molecular testing does not yield results for all antituberculous drugs. We addressed these challenges by utilizing real-time PCR of mycobacteriophage D29 DNA to evaluate the drug resistance of clinical M. tuberculosis isolates. Mycobacteriophages infect and replicate in viable bacterial cells faster than bacterial cells replicate and have been used for detection and drug resistance testing for M. tuberculosis either by using reporter cells or phages with engineered reporter constructs. Our primary protocol involved culturing M. tuberculosis isolates for 48 h with and without drugs at critical concentrations, followed by incubation with 10(3) PFU/ml of D29 mycobacteriophage for 24 h and then real-time PCR. Many drugs could be incubated instantly with M. tuberculosis and phage for 24 h alone. The change in phage DNA real-time PCR cycle threshold (C(T)) between control M. tuberculosis and M. tuberculosis treated with drugs was calculated and correlated with conventional agar proportion drug susceptibility results. Specifically, 9 susceptible clinical isolates, 22 multidrug-resistant (MDR), and 1 extensively drug-resistant (XDR) M. tuberculosis strains were used and C(T) control-C(T) drug cutoffs of between +0.3 and -6.0 yielded 422/429 (98%) accurate results for isoniazid, rifampin, streptomycin, ethambutol, amikacin, kanamycin, capreomycin, ofloxacin, moxifloxacin, ethionamide, para-aminosalicylic acid, cycloserine, and linezolid. Moreover, the ΔC(T) values correlated with isolate MIC for most agents. This D29 quantitative PCR assay offers a rapid, accurate, 1- to 3-day phenotypic drug susceptibility test for first- and second-line drugs and may suggest an approximate MIC.

  17. FPGA implementation of principal component regression (PCR) for real-time differentiation of dopamine from interferents.

    Science.gov (United States)

    Bozorgzadeh, Bardia; Covey, Daniel P; Garris, Paul A; Mohseni, Pedram

    2015-01-01

    This paper reports on field-programmable gate array (FPGA) implementation of a digital signal processing (DSP) unit for real-time processing of neurochemical data obtained by fast-scan cyclic voltammetry (FSCV) at a carbonfiber microelectrode (CFM). The DSP unit comprises a decimation filter and two embedded processors to process the FSCV data obtained by an oversampling recording front-end and differentiate the target analyte from interferents in real time with a chemometrics algorithm using principal component regression (PCR). Interfaced with an integrated, FSCV-sensing front-end, the DSP unit successfully resolves the dopamine response from that of pH change and background-current drift, two common dopamine interferents, in flow injection analysis involving bolus injection of mixed solutions, as well as in biological tests involving electrically evoked, transient dopamine release in the forebrain of an anesthetized rat.

  18. Amp-PCR: combining a random unbiased Phi29-amplification with a specific real-time PCR, performed in one tube to increase PCR sensitivity.

    Directory of Open Access Journals (Sweden)

    Lena Erlandsson

    Full Text Available In clinical situations where a diagnostic real-time PCR assay is not sensitive enough, leading to low or falsely negative results, or where detection earlier in a disease progression would benefit the patient, an unbiased pre-amplification prior to the real-time PCR could be beneficial. In Amp-PCR, an unbiased random Phi29 pre-amplification is combined with a specific real-time PCR reaction. The two reactions are separated physically by a wax-layer (AmpliWax® and are run in sequel in the same sealed tube. Amp-PCR can increase the specific PCR signal at least 100×10(6-fold and make it possible to detect positive samples normally under the detection limit of the specific real-time PCR. The risk of contamination is eliminated and Amp-PCR could replace nested-PCR in situations where increased sensitivity is needed e.g. in routine PCR diagnostic analysis. We show Amp-PCR to work on clinical samples containing circular and linear viral dsDNA genomes, but can work well on DNA of any origin, both from non-cellular (virus and cellular sources (bacteria, archae, eukaryotes.

  19. Validation of a real-time PCR assay for the molecular identification of Mycobacterium tuberculosis.

    Science.gov (United States)

    Sales, Mariana L; Fonseca Júnior, Antônio Augusto; Orzil, Lívia; Alencar, Andrea Padilha; Silva, Marcio Roberto; Issa, Marina Azevedo; Soares Filho, Paulo Martins; Lage, Andrey Pereira; Heinemann, Marcos Bryan

    2014-01-01

    Mycobacterium tuberculosis is the major cause of tuberculosis in humans. This bacillus gained prominence with the occurrence of HIV, presenting itself as an important opportunistic infection associated with acquired immunodeficiency syndrome (AIDS). The current study aimed to develop a real-time PCR using Eva Green technology for molecular identification of M. tuberculosis isolates. The primers were designed to Rv1510 gene. Ninety nine samples of M. tuberculosis and sixty samples of M. bovis were tested and no sample of the bovine bacillus was detected by the qPCR. Statistical tests showed no difference between the qPCR and biochemical tests used to identify the Mycobacterium tuberculosis. The correlation between tests was perfect with Kappa index of 1.0 (p tuberculosis in samples of bacterial suspension. TB reference laboratories (health and agriculture sectors), public health programs and epidemiological studies probably may benefit from such method.

  20. Development of real-time PCR method for rapid detection and quantification of Heterosigma akashiwo

    Institute of Scientific and Technical Information of China (English)

    HE Shan-ying; YU Zhi-gang; MI Tie-zhu

    2008-01-01

    To rapidly detect the harmful algae H. Akashiwo qualitatively and quantitatively, sequences of the 18S rDNA deduced from H. Akashiwo were used for designing species-specific primers, and a RFQ-PCR (Real-time Fluorescent Quantitative Polymerase Chain Reaction) method was developed for quantitative detection of H.akashiwo. Primer H. Akashiwo and TaqMan probe were designed, and the specificity of primer was checked with PCR. A calibration curve was constructed with cycle threshold value against visual counted cell number. And the value of the curve was tested with other H. Akashiwo samples, which were assayed with both the RFQ-PCR method and visual count under microscope.

  1. Real-Time PCR Quantification of Chloroplast DNA Supports DNA Barcoding of Plant Species.

    Science.gov (United States)

    Kikkawa, Hitomi S; Tsuge, Kouichiro; Sugita, Ritsuko

    2016-03-01

    Species identification from extracted DNA is sometimes needed for botanical samples. DNA quantification is required for an accurate and effective examination. If a quantitative assay provides unreliable estimates, a higher quantity of DNA than the estimated amount may be used in additional analyses to avoid failure to analyze samples from which extracting DNA is difficult. Compared with conventional methods, real-time quantitative PCR (qPCR) requires a low amount of DNA and enables quantification of dilute DNA solutions accurately. The aim of this study was to develop a qPCR assay for quantification of chloroplast DNA from taxonomically diverse plant species. An absolute quantification method was developed using primers targeting the ribulose-1,5-bisphosphate carboxylase/oxygenase large subunit (rbcL) gene using SYBR Green I-based qPCR. The calibration curve was generated using the PCR amplicon as the template. DNA extracts from representatives of 13 plant families common in Japan. This demonstrates that qPCR analysis is an effective method for quantification of DNA from plant samples. The results of qPCR assist in the decision-making will determine the success or failure of DNA analysis, indicating the possibility of optimization of the procedure for downstream reactions.

  2. Polymerase chain reaction and real-time PCR for diagnosing of Leishmania infantum chagasi in dogs.

    Science.gov (United States)

    Ramos, Rafael Antonio do Nascimento; Ramos, Carlos Alberto do Nascimento; Jusi, Márcia Mariza Gomes; de Araújo, Flábio Ribeiro; Machado, Rosangela Zacarias; Faustino, Maria Aparecida da Glória; Alves, Leucio Câmara

    2012-01-01

    The importance of dogs as a reservoir for Leishmania infantumchagasi in urban environments has stimulated numerous studies assessing diagnostic techniques. When performed properly, such procedures are an important step in preventing leishmaniasis in humans. Molecular methods have become prominent for this purpose. The aim of the present study was to determine the performance of the polymerase chain reaction (PCR) and real-time PCR (qPCR) for diagnosing of canine visceral leishmaniasis (CVL) using different biological samples. For this, 35 dogs from an area endemic for CVL were used. Bone marrow aspirate and lymph node and spleen fragments from these dogs were used for the molecular diagnosis. In the present study, qPCR was able to detect a greater number of positive animals than seen with PCR. Among the different biological samples used, there was no significant difference in L. infantumchagasi DNA detection between PCR and qPCR. However, considering that lymph nodes are easy to acquire, these can be considered to be the best samples for making molecular diagnoses of L. infantum chagasi infection.

  3. SIMPLIFYING CELIAC DISEASE PREDISPOSING HLA-DQ ALLELES DETERMINATION BY THE REAL TIME PCR METHOD

    Directory of Open Access Journals (Sweden)

    Nicole SELLESKI

    2015-06-01

    Full Text Available Background Celiac disease is an autoimmune enteropathy triggered by the ingestion of gluten in genetically susceptible individuals. Genetic susceptibility is associated with two sets of alleles, DQA1*05 - DQB1*02 and DQA1*03 - DQB1*03:02, which code for class II MHC DQ2 and DQ8 molecules, respectively. Approximately 90%-95% of celiac patients are HLA-DQ2 positive, and half of the remaining patients are HLA-DQ8 positive. In fact, during a celiac disease diagnostic workup, the absence of these specific DQA and DQB alleles has a near perfect negative predictive value. Objective Improve the detection of celiac disease predisposing alleles by combining the simplicity and sensitivity of real-time PCR (qPCR and melting curve analysis with the specificity of sequence-specific primers (SSP. Methods Amplifications of sequence-specific primers for DQA1*05 (DQ2, DQB1*02 (DQ2, and DQA1*03 (DQ8 were performed by the real time PCR method to determine the presence of each allele in independent reactions. Primers for Human Growth Hormone were used as an internal control. A parallel PCR-SSP protocol was used as a reference method to validate our results. Results Both techniques yielded equal results. From a total of 329 samples the presence of HLA predisposing alleles was determined in 187 (56.8%. One hundred fourteen samples (61% were positive for a single allele, 68 (36.3% for two alleles, and only 5 (2.7% for three alleles. Conclusion Results obtained by qPCR technique were highly reliable with no discordant results when compared with those obtained using PCR-SSP.

  4. Evaluation of Four Endogenous Reference Genes and Their Real-Time PCR Assays for Common Wheat Quantification in GMOs Detection

    Science.gov (United States)

    Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao

    2013-01-01

    Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat. PMID:24098735

  5. Evaluation of four endogenous reference genes and their real-time PCR assays for common wheat quantification in GMOs detection.

    Directory of Open Access Journals (Sweden)

    Huali Huang

    Full Text Available Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L. DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat.

  6. Universal Probe Library based real-time PCR for rapid detection of bacterial pathogens from positive blood culture bottles.

    Science.gov (United States)

    Zhu, Lingxiang; Shen, Ding-Xia; Zhou, Qiming; Liu, Chao-Jun; Li, Zexia; Fang, Xiangdong; Li, Quan-Zhen

    2014-03-01

    A set of real-time PCR based assays using the locked nucleic acid probes from Roche Universal ProbeLibrary were developed for rapid detection of eight bacterial species from positive blood culture bottles. Four duplex real-time PCR reactions targeting to one Gram-positive bacterium and one Gram-negative bacterium were optimized for species identification according to Gram stain results. We also included mecA-specific primers and probes in the assays to indicate the presence of methicillin resistance in the bacterial species. The analytical sensitivity was in the range of 1-10 CFU per PCR reaction mixture. The specificity and cross reactivity of the assay was validated by 28 ATCC reference strains and 77 negative blood culture specimens. No cross-reactivity was observed in these samples thus demonstrating 100 % specificity. 72 previously characterized clinical isolates were tested by the real-time PCR assay and validated the accuracy and feasibility of the real-time PCR assay. Furthermore, 55 positive blood culture samples were tested using real-time PCR and 50 (90.9 %) of them were identified as the same species as judged by biochemical analysis. In total, real-time PCR showed 98.2 % consistent to that of traditional methods. Real-time PCR can be used as a supplement for early detection of the frequently-occurred pathogens from the positive blood cultures.

  7. Evaluation of four endogenous reference genes and their real-time PCR assays for common wheat quantification in GMOs detection.

    Science.gov (United States)

    Huang, Huali; Cheng, Fang; Wang, Ruoan; Zhang, Dabing; Yang, Litao

    2013-01-01

    Proper selection of endogenous reference genes and their real-time PCR assays is quite important in genetically modified organisms (GMOs) detection. To find a suitable endogenous reference gene and its real-time PCR assay for common wheat (Triticum aestivum L.) DNA content or copy number quantification, four previously reported wheat endogenous reference genes and their real-time PCR assays were comprehensively evaluated for the target gene sequence variation and their real-time PCR performance among 37 common wheat lines. Three SNPs were observed in the PKABA1 and ALMT1 genes, and these SNPs significantly decreased the efficiency of real-time PCR amplification. GeNorm analysis of the real-time PCR performance of each gene among common wheat lines showed that the Waxy-D1 assay had the lowest M values with the best stability among all tested lines. All results indicated that the Waxy-D1 gene and its real-time PCR assay were most suitable to be used as an endogenous reference gene for common wheat DNA content quantification. The validated Waxy-D1 gene assay will be useful in establishing accurate and creditable qualitative and quantitative PCR analysis of GM wheat.

  8. Validation of absolute quantitative real-time PCR for the diagnosis of Streptococcus agalactiae in fish.

    Science.gov (United States)

    Sebastião, Fernanda de A; Lemos, Eliana G M; Pilarski, Fabiana

    2015-12-01

    Streptococcus agalactiae (GBS) are Gram-positive cocci responsible for substantial losses in tilapia fish farms in Brazil and worldwide. It causes septicemia, meningoencephalitis and mortality of whole shoals that can occur within 72 h. Thus, diagnostic methods are needed that are rapid, specific and sensitive. In this study, a pair of specific primers for GBS was generated based on the cfb gene sequence and initially evaluated by conventional PCR. The protocols for absolute quantitative real-time PCR (qPCR) were then adapted to validate the technique for the identification and quantification of GBS isolated by real-time detection of amplicons using fluorescence measurements. Finally, an infectivity test was conducted in tilapia infected with GBS strains. Total DNA from the host brain was subjected to the same technique, and the strains were re-isolated to validate Koch's postulates. The assay showed 100% specificity for the other bacterial species evaluated and a sensitivity of 367 gene copies per 20 mg of brain tissue within 4 h, making this test a valuable tool for health monitoring programs.

  9. Quantification of rice blast disease progressions through Taqman real-time PCR.

    Science.gov (United States)

    Su'udi, Mukhamad; Kim, Jinyeong; Park, Jong-Mi; Bae, Shin-Chul; Kim, Donghern; Kim, Yong-Hwan; Ahn, Il-Pyung

    2013-09-01

    Rice blast caused by Magnaporthe oryzae is a major disease in the paddy field and also a representative model system in the investigation of plant-microbe interactions. This study was undertaken to provide the quantitative evaluation method that specifically determines the amount of M. oryzae proliferation in planta. Real-time PCR was used as the detection strategy in combination with the primer pair and Taqman probe specific to MHP1, a unigene encoding HYDROPHOBIN that is indispensable for normal virulence expression. Based on the crossing point values from the PCR reactions containing a series of increasing concentration of cloned amplicon or fungal genomic DNA, correlation among the template's copy number or its amount and amplification pattern was calculated. Reliability of this equation was further confirmed using the DNA samples from the rice leaves infected with compatible or incompatible strains of M. oryzae. The primer pair used in the Taqman real-time PCR reaction can recognize the existence of fungal DNA as low as 1 pg. In sum, our quantitative evaluation system is applicable and reliable in the blast diagnosis and also in the estimation of objective blast disease progression.

  10. Molecular diagnosis of Kingella kingae osteoarticular infections by specific real-time PCR assay.

    Science.gov (United States)

    Cherkaoui, Abdessalam; Ceroni, Dimitri; Emonet, Stéphane; Lefevre, Yan; Schrenzel, Jacques

    2009-01-01

    Kingella kingae is an emerging pathogen that is recognized as a causative agent of septic arthritis and osteomyelitis, primarily in infants and children. The bacterium is best detected by rapid inoculation in blood culture systems or by real-time PCR assays. Pathogenesis of the agent was linked recently to the production of a potent cytotoxin, known as RTX, which is toxic to a variety of human cell types. The locus encoding the RTX toxin is thought to be a putative virulence factor, and is, apparently, essential for inducing cytotoxic effects on respiratory epithelial, synovial and macrophage-like cells. Herein, we describe a novel real-time PCR assay that targets the RTX toxin gene and illustrate its use in two clinical cases. The assay exhibited a sensitivity of 30 c.f.u., which is 10-fold more sensitive than a previously published semi-nested broad-range 16S rRNA gene PCR, and showed no cross-reactivity with several related species and common osteoarticular pathogens.

  11. Critical analysis of rhinovirus RNA load quantification by real-time reverse transcription-PCR.

    Science.gov (United States)

    Schibler, Manuel; Yerly, Sabine; Vieille, Gaël; Docquier, Mylène; Turin, Lara; Kaiser, Laurent; Tapparel, Caroline

    2012-09-01

    Rhinoviruses are the most frequent cause of human respiratory infections, and quantitative rhinovirus diagnostic tools are needed for clinical investigations. Although results obtained by real-time reverse-transcription PCR (RT-PCR) assays are frequently converted to viral RNA loads, this presents several limitations regarding accurate virus RNA quantification, particularly given the need to reliably quantify all known rhinovirus genotypes with a single assay. Using an internal extraction control and serial dilutions of an in vitro-transcribed rhinovirus RNA reference standard, we validated a quantitative one-step real-time PCR assay. We then used chimeric rhinovirus genomes with 5'-untranslated regions (5'UTRs) originating from the three rhinovirus species and from one enterovirus to estimate the impact of the 5'UTR diversity. Respiratory specimens from infected patients were then also analyzed. The assay quantification ability ranged from 4.10 to 9.10 log RNA copies/ml, with an estimated error margin of ±10%. This variation was mainly linked to target variability and interassay variability. Taken together, our results indicate that our assay can reliably estimate rhinovirus RNA load, provided that the appropriate error margin is used. In contrast, due to the lack of a universal rhinovirus RNA standard and the variability related to sample collection procedures, accurate absolute rhinovirus RNA quantification in respiratory specimens is currently hardly feasible.

  12. Simultaneous detection, typing and quantitation of oncogenic human papillomavirus by multiplex consensus real-time PCR.

    Science.gov (United States)

    Jenkins, Andrew; Allum, Anne-Gry; Strand, Linda; Aakre, Randi Kersten

    2013-02-01

    A consensus multiplex real-time PCR test (PT13-RT) for the oncogenic human papillomavirus (HPV) types 16, 18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59 and 66 is described. The test targets the L1 gene. Analytical sensitivity is between 4 and 400 GU (genomic units) in the presence of 500 ng of human DNA, corresponding to 75,000 human cells. HPV types are grouped into multiplex groups of 3 or 4 resulting in the use of 4 wells per sample and permitting up to 24 samples per run (including controls) in a standard 96-well real-time PCR instrument. False negative results are avoided by (a) measuring sample DNA concentration to control that sufficient cellular material is present and (b) including HPV type 6 as a homologous internal control in order to detect PCR inhibition or competition from other (non-oncogenic) HPV types. Analysis time from refrigerator to report is 8 h, including 2.5 h hands-on time. Relative to the HC2 test, the sensitivity and specificity were respectively 98% and 83%, the lower specificity being attributable to the higher analytical sensitivity of PT13-RT. To assess type determination comparison was made with a reversed line-blot test. Type concordance was high (κ=0.79) with discrepancies occurring mostly in multiple-positive samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  13. Correlation Coefficients Between Different Methods of Expressing Bacterial Quantification Using Real Time PCR

    Directory of Open Access Journals (Sweden)

    Bahman Navidshad

    2012-02-01

    Full Text Available The applications of conventional culture-dependent assays to quantify bacteria populations are limited by their dependence on the inconsistent success of the different culture-steps involved. In addition, some bacteria can be pathogenic or a source of endotoxins and pose a health risk to the researchers. Bacterial quantification based on the real-time PCR method can overcome the above-mentioned problems. However, the quantification of bacteria using this approach is commonly expressed as absolute quantities even though the composition of samples (like those of digesta can vary widely; thus, the final results may be affected if the samples are not properly homogenized, especially when multiple samples are to be pooled together before DNA extraction. The objective of this study was to determine the correlation coefficients between four different methods of expressing the output data of real-time PCR-based bacterial quantification. The four methods were: (i the common absolute method expressed as the cell number of specific bacteria per gram of digesta; (ii the Livak and Schmittgen, ΔΔCt method; (iii the Pfaffl equation; and (iv a simple relative method based on the ratio of cell number of specific bacteria to the total bacterial cells. Because of the effect on total bacteria population in the results obtained using ΔCt-based methods (ΔΔCt and Pfaffl, these methods lack the acceptable consistency to be used as valid and reliable methods in real-time PCR-based bacterial quantification studies. On the other hand, because of the variable compositions of digesta samples, a simple ratio of cell number of specific bacteria to the corresponding total bacterial cells of the same sample can be a more accurate method to quantify the population.

  14. Reliability of quantitative real-time PCR for bacterial detection in cystic fibrosis airway specimens.

    Directory of Open Access Journals (Sweden)

    Edith T Zemanick

    Full Text Available The cystic fibrosis (CF airway microbiome is complex; polymicrobial infections are common, and the presence of fastidious bacteria including anaerobes make culture-based diagnosis challenging. Quantitative real-time PCR (qPCR offers a culture-independent method for bacterial quantification that may improve diagnosis of CF airway infections; however, the reliability of qPCR applied to CF airway specimens is unknown. We sought to determine the reliability of nine specific bacterial qPCR assays (total bacteria, three typical CF pathogens, and five anaerobes applied to CF airway specimens. Airway and salivary specimens from clinically stable pediatric CF subjects were collected. Quantitative PCR assay repeatability was determined using triplicate reactions. Split-sample measurements were performed to measure variability introduced by DNA extraction. Results from qPCR were compared to standard microbial culture for Pseudomonas aeruginosa, Staphylococcus aureus, and Haemophilus influenzae, common pathogens in CF. We obtained 84 sputa, 47 oropharyngeal and 27 salivary specimens from 16 pediatric subjects with CF. Quantitative PCR detected bacterial DNA in over 97% of specimens. All qPCR assays were highly reproducible at quantities≥10(2 rRNA gene copies/reaction with coefficient of variation less than 20% for over 99% of samples. There was also excellent agreement between samples processed in duplicate. Anaerobic bacteria were highly prevalent and were detected in mean quantities similar to that of typical CF pathogens. Compared to a composite gold standard, qPCR and culture had variable sensitivities for detection of P. aeruginosa, S. aureus and H. influenzae from CF airway samples. By reliably quantifying fastidious airway bacteria, qPCR may improve our understanding of polymicrobial CF lung infections, progression of lung disease and ultimately improve antimicrobial treatments.

  15. Detection of Cryptococcus neoformans DNA in Tissue Samples by Nested and Real-Time PCR Assays

    Science.gov (United States)

    Bialek, Ralf; Weiss, Michael; Bekure-Nemariam, Kubrom; Najvar, Laura K.; Alberdi, Maria B.; Graybill, John R.; Reischl, Udo

    2002-01-01

    Two PCR protocols targeting the 18S rRNA gene of Cryptococcus neoformans were established, compared, and evaluated in murine cryptococcal meningitis. One protocol was designed as a nested PCR to be performed in conventional block thermal cyclers. The other protocol was designed as a quantitative single-round PCR adapted to LightCycler technology. One hundred brain homogenates and dilutions originating from 20 ICR mice treated with different azoles were examined. A fungal burden of 3 × 101 to 2.9 × 104 CFU per mg of brain tissue was determined by quantitative culture. Specific PCR products were amplified by the conventional and the LightCycler methods in 86 and 87 samples, respectively, with products identified by DNA sequencing and real-time fluorescence detection. An analytical sensitivity of 1 CFU of C. neoformans per mg of brain tissue and less than 10 CFU per volume used for extraction was observed for both PCR protocols, while homogenates of 70 organs from mice infected with other fungi were PCR negative. Specificity testing was performed with genomic DNA from 31 hymenomycetous fungal species and from the ustilaginomycetous yeast Malassezia furfur, which are phylogenetically related to C. neoformans. Twenty-four strains, including species of human skin flora like M. furfur and Trichosporon spp., were PCR negative. Amplification was observed with Cryptococcus amylolentus, Filobasidiella depauperata, Cryptococcus laurentii, and five species unrelated to clinical specimens. LightCycler PCR products from F. depauperata and Trichosporon faecale could be clearly discriminated by melting curve analysis. The sensitive and specific nested PCR assay as well as the rapid and quantitative LightCycler PCR assay might be useful for the diagnosis and monitoring of human cryptococcal infections. PMID:11874894

  16. Development and Evaluation of a Novel Real-Time PCR for Pan-Dermatophyte Detection in Nail Specimens.

    Science.gov (United States)

    Gong, Jie; Ran, Menglong; Wang, Xiaowen; Wan, Zhe; Li, Ruoyu

    2016-02-01

    An accurate diagnosis of tinea unguium is necessary for the selection of antimycotics and successful treatment. To rapidly and accurately identify the aetiological agents causing tinea unguium, we improved upon the conventional boiling method for DNA extraction and developed a novel real-time PCR detection system that includes two assays. The two assays, based on the amplification of ribosomal internal transcribed spacer regions and 28S rDNA, were designed to detect pan-dermatophyte and Trichophyton rubrum, respectively. The analytical sensitivities of both assays permitted the detection of ten copies of plasmid DNA template. The analytical specificity of the detection system was confirmed using 11 dermatophyte strains and 25 non-dermatophyte strains. In total, 165 nail specimens were examined by microscopy, culture, conventional PCR, and the novel real-time PCR method. Real-time PCR gave positive results in 47.3 % of the specimens (78), a rate exceeding those obtained using microscopy (72, 43.6 %), conventional PCR (69, 41.8 %), and culture (49, 29.7 %). All conventional PCR-positive specimens were detected by real-time PCR, and real-time PCR detected nine specimens that were missed by conventional PCR. The results from latent class analysis, and further calculations, showed that real-time PCR was the most sensitive method, but the diagnostic specificity of the four approaches was equivalent. In particular, molecular approaches may be more effective than microscopy and culture when the clinical symptoms of tinea unguium are not evident.

  17. Development of multiplex real-time PCR assay for the detection of Brucella spp., Leptospira spp. and Campylobacter foetus

    Directory of Open Access Journals (Sweden)

    Abdelfattah M. Selim

    2014-12-01

    Full Text Available Abortion among dairy cattle is one of the major causes of economic losses in the livestock industry. This study describes a 1-step multiplex real-time polymerase chain reaction (PCR to detect Brucella spp., Leptospira spp. and Campylobacter foetus, these are significant bacteria commonly implicated in bovine abortion. ß-actin was added to the same PCR reaction as an internal control to detect any extraction failure or PCR inhibition. The detection limit of multiplex real-time PCR using purified DNA from cultured organisms was set to 5 fg for Leptospira spp. and C. foetus and to 50 fg for Brucella spp. The multiplex real-time PCR did not produce any non-specific amplification when tested with different strains of the 3 pathogens. This multiplex real-time PCR provides a valuable tool for diagnosis, simultaneous and rapid detection for the 3 pathogens causing abortion in bovine.

  18. Evaluation of real-time PCR for diagnosis of Bordetella pertussis infection

    Directory of Open Access Journals (Sweden)

    Fox Julie D

    2006-03-01

    Full Text Available Abstract Background Nucleic acid amplification of the IS481 region by PCR is more sensitive than culture for detection and diagnosis of Bordetella pertussis but the assay has known cross-reactivity for Bordetella holmesii and its use as a routine diagnostic assay has not been widely evaluated. Methods The objectives of this study were: 1 to assess the diagnostic utility of real-time IS481 PCR by comparison of results with culture and direct fluorescent antigen (DFA testing for B. pertussis, 2 to employ a PCR assay designed against a different insertion sequence (IS1001 to assess the incidence of B. holmesii in symptomatic individuals and 3 to design and evaluate a new PCR-based assay which could be used for B. pertussis confirmation. A total of 808 nasopharyngeal specimens were included in the study the majority of which were submitted in charcoal transport medium (88% with the rest submitted in Regan-Lowe medium. Results Concordant results for PCR, DFA and culture were obtained for 21 B. pertussis positive and 729 B. pertussis negative specimens. DFA was prone to false positive and negative reactions when compared with both PCR and culture. The IS481 PCR identified 28 positive results for specimens that were DFA and culture negative. A novel real-time PCR targeting the B. pertussis toxin promoter was found to be specific and useful for confirming the majority of IS481 positive specimens as B. pertussis. B. holmesii was not detected in any of the submitted samples. Conclusion The potential pick up of B. holmesii by the IS481 PCR had minimal diagnostic relevance in the Alberta population during the time period of our study. The IS481 PCR assay is now used in our laboratory routinely for front-line screening of samples for B. pertussis with associated enhancement in diagnostic sensitivity compared with DFA and culture. Retrospectively, patients' samples are batched and tested by the IS1001 MB and TPR assays for research purposes and to ensure

  19. Soft Fruit Traceability in Food Matrices using Real-Time PCR

    Directory of Open Access Journals (Sweden)

    Elisa Bozza

    2009-12-01

    Full Text Available Food product authentication provides a means of monitoring and identifying products for consumer protection and regulatory compliance. There is a scarcity of analytical methods for confirming the identity of fruit pulp in products containing Soft Fruit. In the present work we have developed a very sensible qualitative and quantitative method to determine the presence of berry DNAs in different food matrices. To our knowledge, this is the first study that shows the applicability, to Soft Fruit traceability, of melting curve analysis and multiplexed fluorescent probes, in a Real-Time PCR platform. This methodology aims to protect the consumer from label misrepresentation.

  20. A Real-Time PCR Method Targeting Camel Ingredient for Food Authentication.

    Science.gov (United States)

    Wu, Yajun; Yang, Yange; Wang, Bin; Liu, Mingchang; Han, Jianxun; Chen, Ying

    2015-01-01

    The special nutritious value of camel showed high potential for market exploitation. In this paper, a real-time PCR method targeting camel ingredient in camel meat and milk is reported as an approach to fight against adulteration. To understand the impact of processing procedures on the amplifiability of cytb gene, four kinds of processed camel meat were investigated, and the rate of DNA breakage was explored. The method was able to detect 5 fg/μL camel DNA and highly processed food containing 0.01% camel meat with a high confidence level.

  1. Quantitation of Rabbit Cytokine mRNA by Real-Time RT-PCR

    OpenAIRE

    Godornes, Charmie; Leader, Brandon Troy; Molini, Barbara J.; Centurion-Lara, Arturo; Lukehart, Sheila A.

    2007-01-01

    Fundamental understanding of rabbit immunology and the use of the rabbit as a disease model have long been hindered by the lack of immunological assays specific to this species. In the present study, we sought to develop a method to quantitate cytokine expression in rabbit cells and tissues. We report the development of a quantitative real-time RT-PCR method for measuring the relative levels of rabbit IFN-γ, IL-2, IL-4, IL-10 and TNF-α mRNA. Quantitation was accomplished by comparison to a st...

  2. A real-time PCR assay for the detection of atypical strains of Chlamydiaceae from pigeons.

    Directory of Open Access Journals (Sweden)

    Aleksandar Zocevic

    Full Text Available Recent evidence of the occurrence of atypical Chlamydiaceae strains in pigeons, different from the established Chlamydiaceae, requires the development of a specific and rapid detection tool to investigate their prevalence and significance. Here is described a new real-time PCR assay that allows specific detection of atypical Chlamydiaceae from pigeons. The assay has been used to assess the dissemination of these strains in field samples collected from Parisian pigeon populations in 2009. The results suggest a limited dissemination compared to the usually higher prevalence of Chlamydia psittaci that is the main species associated with avian chlamydiosis.

  3. Development of a multiplex real-time PCR assay for phylogenetic analysis of Uropathogenic Escherichia coli.

    Science.gov (United States)

    Hasanpour, Mojtaba; Najafi, Akram

    2017-03-28

    Uropathogenic Escherichia coli (UPEC) is among major pathogens causing 80-90% of all episodes of urinary tract infections (UTIs). Recently, E. coli strains are divided into eight main phylogenetic groups including A, B1, B2, C, D, E, F, and clade I. This study was aimed to develop a rapid, sensitive, and specific multiplex real time PCR method capable of detecting phylogenetic groups of E. coli strains. This study was carried out on E. coli strains (isolated from the patient with UTI) in which the presence of all seven target genes had been confirmed in our previous phylogenetic study. An EvaGreen-based singleplex and multiplex real-time PCR with melting curve analysis was designed for simultaneous detection and differentiation of these genes. The primers were selected mainly based on the production of amplicons with melting temperatures (Tm) ranging from 82°C to 93°C and temperature difference of more than 1.5°C between each peak.The multiplex real-time PCR assays that have been developed in the present study were successful in detecting the eight main phylogenetic groups. Seven distinct melting peaks were discriminated, with Tm value of 93±0.8 for arpA, 89.2±0.1for chuA, 86.5±0.1 for yjaA, 82.3±0.2 for TspE4C2, 87.8±0.1for trpAgpC, 85.4±0.6 for arpAgpE genes, and 91±0.5 for the internal control. To our knowledge, this study is the first melting curve-based real-time PCR assay developed for simultaneous and discrete detection of these seven target genes. Our findings showed that this assay has the potential to be a rapid, reliable and cost-effective alternative for routine phylotyping of E. coli strains.

  4. Detection of Fusobacterium necrophorum subsp funduliforme in tonsillitis in young adults by real-time PCR

    DEFF Research Database (Denmark)

    Jensen, Anders; Hagelskjær Kristensen, Lena; Prag, Jørgen

    2007-01-01

    Throat swabs from 61 patients, aged 18-32 years, with non-streptococcal tonsillitis (NST) and 92 healthy controls were examined for the presence of Fusobacterium necrophorum DNA using a novel TaqMan-based real-time quantitative PCR assay for F. necrophorum subspecies. The assay was based on the gyr...... that on swabs from controls (p compared to patients with acute NST (p 0.04). In addition, 26 patients with tonsillitis and group C streptococci (GCS) had a significantly higher load of F. necrophorum DNA...... compared to the NST group (p

  5. Role of real-time PCR (RT-PCR) in rapid diagnosis of tuberculous mycobacteria in different clinical samples.

    Science.gov (United States)

    2014-02-01

    The study was aimed for molecular detection of mycobacterial DNA in different clinical samples using real-time polymerase chain reaction (RT-PCR) system and rapid diagnosis of tuberculosis. A total of 508 clinical specimens (blood 343, menstrual fluid 53, endometrial tissue 43, body fluid 36, pus from lymph nodes 18, sputum 8, urine 5 and semen 2) were included in this study. We extracted DNA using QIAamp DNA Mini Kit (QIAGEN, Germany) and performed real-time assay using Rotor-Gene Q machine from Corbett Research, Australia for specific amplification of IS6110 sequence of mycobacterial genome. The RT-PCR result was also compared with bacterial culture and acid-fast bacillus staining. RT-PCR assay showed positivity in 52 cases and negative in 456 cases. Corresponding positive results in culture and acid-fast bacillus staining methods were 49 cases and 24 cases respectively. The sensitivity and specificity of detecting Mycobacterium tuberculosis by RT-PCR were 93.87% and 98.69% respectively taking positive culture results as reference standards. The overall positive and negative predictive values were 88.46% and 99.34% respectively. RT-PCR is a useful diagnostic tool for rapid and sensitive detection of mycobacteria in different clinical samples. The easy processing, fast reporting and relative lack of contamination issues make it worthy as a possible replacement to time consuming culture techniques. Moreover, it has added advantage of quantification of mycobacterial DNA, hence bacterial load.

  6. Quantification of GPCR mRNA using real-time RT-PCR.

    Science.gov (United States)

    Brattelid, Trond; Levy, Finn Olav

    2011-01-01

    Characterisation of G-protein-coupled receptor (GPCR) mRNA expression under normal, different pharmacological and pathological conditions in experimental animal models and human tissue biopsies by quantitative real-time reverse transcription polymerase chain reaction (RT-qPCR) is a valuable approach to understand the regulation of GPCR expression. RT-qPCR is specific and sensitive with a broad dynamic range, which allows precise quantification of mRNA species of interest. In addition to measuring the relative levels of mRNA in a tissue or changes in expression levels between groups of genes of interest, RT-qPCR is also used to identify splice variants and single nucleotide polymorphisms (SNPs) of GPCRs. Even though RT-qPCR has become the standard method for quantification of gene expression, RT-qPCR is sensitive to RNA quality, assay design, normalisation approach and data analysis. This protocol is meant as a guide to RT-qPCR methodology with references to the best standard methods available at present.

  7. Development of Quantitative Real-time PCR Assays for Different Clades of “Candidatus Accumulibacter”

    Science.gov (United States)

    Zhang, An Ni; Mao, Yanping; Zhang, Tong

    2016-05-01

    We designed novel quantitative real-time polymerase chain reaction (qPCR) primers for the polyphosphate kinase 1 (ppk1) gene, targeting eight individual “Candidatus Accumulibacter” (referred to as Accumulibacter) clades. An evaluation of primer sets was conducted regarding the coverage, specificity, and PCR efficiency. (i) All primer sets were designed to cover all available sequences of the target clade. (ii) The phylogenetic analysis of the sequences retrieved from the qPCR products by each primer set demonstrated a high level of specificity. (iii) All calibration curves presented high PCR efficiencies in the range of 85–112% (R2 = 0.962–0.998). In addition, the possible interference of non-target amplicons was individually examined using the qPCR assay for 13 Accumulibacter clades, which were either undetected or showed negligible detection. With the primers designed by other research groups, a highly selective and sensitive qPCR-based method was developed to quantify all Accumulibacter clades, with the exception of Clade IE, in one assay, which enables more comprehensive insights into the community dynamics. The applicability to environmental samples was demonstrated by profiling the Accumulibacter clades in activated sludge samples of nine full-scale wastewater treatment plants.

  8. A duplex real-time RT-PCR assay for profiling inhibitors of four dengue serotypes.

    Science.gov (United States)

    Gong, Edwin Yunhao; Smets, Alexandra; Verheyen, Nick; Clynhens, Marleen; Gustin, Emmanuel; Lory, Pedro; Kraus, Guenter

    2013-01-01

    We have developed a duplex real-time RT-PCR assay for profiling antiviral inhibitors of four dengue virus (DENV) serotypes. In this assay, the primers and the probe for amplifying DENV were designed in the conserved regions of the genome after aligned more than 300 nucleotide sequences of four dengue serotypes deposited in the GeneBank. To discriminate the antiviral activity from the cytotoxicity of compounds, a housekeeping gene of the Vero cells, β-actin, was used to design the primers and the probe for the second set of PCR as an internal control, which is used to normalize the RNA levels of dengue-specific PCR due to the cellular toxicity of test compounds. For compound profiling, the duplex PCR is performed using LightCycler(®) in a single tube to simultaneously amplify both the dengue target gene and the Vero cell housekeeping gene from the compound-treated Vero cell lysates. This assay was validated against a panel of reference compounds. The results show that the universal primers and probe in this duplex RT-PCR assay can efficiently amplify all four dengue serotypes and that the PCR efficiency for both the dengue target gene and the Vero cells β-actin gene is 100%.

  9. Interlaboratory comparison of real-time pcr protocols for quantification of general fecal indicator bacteria

    Science.gov (United States)

    Shanks, O.C.; Sivaganesan, M.; Peed, L.; Kelty, C.A.; Blackwood, A.D.; Greene, M.R.; Noble, R.T.; Bushon, R.N.; Stelzer, E.A.; Kinzelman, J.; Anan'Eva, T.; Sinigalliano, C.; Wanless, D.; Griffith, J.; Cao, Y.; Weisberg, S.; Harwood, V.J.; Staley, C.; Oshima, K.H.; Varma, M.; Haugland, R.A.

    2012-01-01

    The application of quantitative real-time PCR (qPCR) technologies for the rapid identification of fecal bacteria in environmental waters is being considered for use as a national water quality metric in the United States. The transition from research tool to a standardized protocol requires information on the reproducibility and sources of variation associated with qPCR methodology across laboratories. This study examines interlaboratory variability in the measurement of enterococci and Bacteroidales concentrations from standardized, spiked, and environmental sources of DNA using the Entero1a and GenBac3 qPCR methods, respectively. Comparisons are based on data generated from eight different research facilities. Special attention was placed on the influence of the DNA isolation step and effect of simplex and multiplex amplification approaches on interlaboratory variability. Results suggest that a crude lysate is sufficient for DNA isolation unless environmental samples contain substances that can inhibit qPCR amplification. No appreciable difference was observed between simplex and multiplex amplification approaches. Overall, interlaboratory variability levels remained low (<10% coefficient of variation) regardless of qPCR protocol. ?? 2011 American Chemical Society.

  10. A quantitative real-time RT-PCR assay for mature C. albicans biofilms

    Directory of Open Access Journals (Sweden)

    Dongari-Bagtzoglou Anna

    2011-05-01

    Full Text Available Abstract Background Fungal biofilms are more resistant to anti-fungal drugs than organisms in planktonic form. Traditionally, susceptibility of biofilms to anti-fungal agents has been measured using the 2,3-bis(2-methoxy-4-nitro-5-sulfophenyl-2H-tetrazolium-5-carboxyanilide (XTT assay, which measures the ability of metabolically active cells to convert tetrazolium dyes into colored formazan derivatives. However, this assay has limitations when applied to high C. albicans cell densities because substrate concentration and solubility are limiting factors in the reaction. Because mature biofilms are composed of high cell density populations we sought to develop a quantitative real-time RT-PCR assay (qRT-PCR that could accurately assess mature biofilm changes in response to a wide variety of anti-fungal agents, including host immune cells. Results The XTT and qRT-PCR assays were in good agreement when biofilm changes were measured in planktonic cultures or in early biofilms which contain lower cell densities. However, the real-time qRT-PCR assay could also accurately quantify small-medium size changes in mature biofilms caused by mechanical biomass reduction, antifungal drugs or immune effector cells, that were not accurately quantifiable with the XTT assay. Conclusions We conclude that the qRT-PCR assay is more accurate than the XTT assay when measuring small-medium size effects of anti-fungal agents against mature biofilms. This assay is also more appropriate when mature biofilm susceptibility to anti-fungal agents is tested on complex biological surfaces, such as organotypic cultures.

  11. Detection of Brucella spp. in bottlenose dolphins Tursiops truncatus by a real-time PCR using blowhole swabs.

    Science.gov (United States)

    Wu, Qingzhong; Conway, Jessica; Phillips, Kristen M; Stolen, Megan; Durden, Wendy N; Fauquier, Deborah; McFee, Wayne E; Schwacke, Lori

    2016-08-09

    Blowhole swabs are a simple and non-invasive method for collecting samples from cetaceans and can be used for screening large numbers of animals in the field. This study reports a real-time PCR assay for the detection of Brucella spp. using blowhole swab samples from bottlenose dolphins Tursiops truncatus stranded in the coastal region of Virginia, South Carolina and northern Florida, USA, between 2013 and 2015. We used real-time PCR results on lung samples from the same dolphins in order to estimate the relative sensitivity and specificity of real-time PCR of blowhole swabs. Brucella DNA was detected in lung tissue of 22% (18/81) and in blowhole swabs of 21% (17/81) of the sampled dolphins. The relative sensitivity and specificity of real-time PCR on blowhole swabs as compared to the real-time PCR on lung samples was 94% (17/18) and 100% (63/63), respectively. These results indicate that real-time PCR on blowhole swabs may be used as a non-invasive test for rapid detection of Brucella spp. in the respiratory tract of dolphins. To our knowledge, this is the first report on the use of blowhole swabs for detection of bacterial pathogens by real-time PCR in bottlenose dolphins.

  12. Galactomannan and Real-Time PCR in the diagnosis of invasive Aspergillosis: preliminary data

    Directory of Open Access Journals (Sweden)

    Cristina Pedrotti

    2014-03-01

    Full Text Available The diagnosis of invasive aspergillosis is notoriously difficult. The standard culture-based methods have shown considerable limitations in performance. For this reason, non-culture methods have been increasingly employed for the diagnosis of invasive aspergillosis, and, among them, the methods based on Real-Time polymerase chain reaction (RT-PCR. In this study we assess the contribution in lowering diagnosis errors provided by the RT-PCR method when run alongside other methods. We analyzed 23 biological samples, 14 serum samples, and 9 bronchoalveolar lavage samples (BAL from 10 immunocompromised patients who were selected according to EORTC/MSG criteria (European Organization for Research and Treatment of Cancer/Mycoses Study Group. On the serum sample we searched the galactomannan (GM (Platelia Aspergillus® and the fungal genome (MycAssayTMAspergillus; the BAL samples were subjected also to the culture tests. In 11 serum samples the results showed concordance between GM and RT–PCR tests, while in 3 samples we report discordance: 2 results were GM positive and RT-PCR negative, and 1 results GM negative and RT-PCR indeterminate. In 5 BAL samples the results showed concordance between the two methods, while 4 were GM positive and RT-PCR negative. The data, although still preliminary, suggest an increased accuracy in the diagnosis of suspected invasive aspergillosis when employing both RT-PCR and GM tests given that the RT-PCR test eliminates the false positive results of the GM test. The PCR methods require, however, further applications of this type of diagnostic because of the severe limit given by the lack of standardization.

  13. The development of a real-time PCR to detect pathogenic Leptospira species in kidney tissue.

    Science.gov (United States)

    Fearnley, C; Wakeley, P R; Gallego-Beltran, J; Dalley, C; Williamson, S; Gaudie, C; Woodward, M J

    2008-08-01

    A LightCycler real-time PCR hybridization probe-based assay that detects a conserved region of the16S rRNA gene of pathogenic but not saprophytic Leptospira species was developed for the rapid detection of pathogenic leptospires directly from processed tissue samples. In addition, a differential PCR specific for saprophytic leptospires and a control PCR targeting the porcine beta-actin gene were developed. To assess the suitability of these PCR methods for diagnosis, a trial was performed on kidneys taken from adult pigs with evidence of leptospiral infection, primarily a history of reproductive disease and serological evidence of exposure to pathogenic leptospires (n=180) and aborted pig foetuses (n=24). Leptospire DNA was detected by the 'pathogenic' specific PCR in 25 tissues (14%) and the control beta-actin PCR was positive in all 204 samples confirming DNA was extracted from all samples. No leptospires were isolated from these samples by culture and no positives were detected with the 'saprophytic' PCR. In a subsidiary experiment, the 'pathogenic' PCR was used to analyse kidney samples from rodents (n=7) collected as part of vermin control in a zoo, with show animals with high microagglutination titres to Leptospira species, and five were positive. Fifteen PCR amplicons from 1 mouse, 2 rat and 14 pig kidney samples, were selected at random from positive PCRs (n=30) and sequenced. Sequence data indicated L. interrogans DNA in the pig and rat samples and L. inadai DNA, which is considered of intermediate pathogenicity, in the mouse sample. The only successful culture was from this mouse kidney and the isolate was confirmed to be L. inadai by classical serology. These data suggest this suite of PCRs is suitable for testing for the presence of pathogenic leptospires in pig herds where abortions and infertility occur and potentially in other animals such as rodents.

  14. Multiplex real-time RT-PCR for detecting chikungunya virus and dengue virus

    Institute of Scientific and Technical Information of China (English)

    Piyathida Pongsiri; Kesmanee Praianantathavorn; Apiradee Theamboonlers; Sunchai Payungporn; Yong Poovorawan

    2012-01-01

    ABSTRACT Objective:To develop diagnostic test for detection chikungunya virus (CHIKV and Dengue virus (DENV)infection.Methods:We have performed a rapid, accurate laboratory confirmative method to simultaneously detect, quantify and differentiateCHIKV and DENV infection by single-step multiplex real-timeRT-PCR.Results: The assay’s sensitivity was97.65%, specificity was 92.59% and accuracy was95.82% when compared to conventional RT-PCR. Additionally, there was no cross-reaction betweenCHIKV, DENV, Japanese encephalitis virus, hepatitis C, hepatitis A or hepatitis E virus.Conclusions:This rapid and reliable assay provides a means for simultaneous early diagnosis ofCHIKV andDENV in a single-step reaction.

  15. Comparison of nine DNA extraction methods for the diagnosis of bovine tuberculosis by real time PCR

    Directory of Open Access Journals (Sweden)

    André Moura

    2016-07-01

    Full Text Available ABSTRACT: Bovine tuberculosis is an infectious disease with a high impact on the cattle industry, particularly in developing countries. PCR is a very sensitive method for detection of infectious agents, but the sensitivity of molecular diagnosis is largely dependent on the efficiency of the DNA extraction methods. The objective of this study was to evaluate DNA extraction methods for direct detection of Mycobacterium bovis in bovine tissue. Nine commercial kits for DNA extraction were evaluated when combined with two real time PCRs. The DNeasy Blood & Tissue Kit from QIAGEN showed better performance and sensitivity followed by the DNA Mini Kit RBC and FTA Elute Micro Card. Results suggested that, even when the analytical sensitivity of the qPCR is very high, the extraction method can influence the diagnostic sensitivity.

  16. Quantification of organellar DNA and RNA using real-time PCR.

    Science.gov (United States)

    Weihe, Andreas

    2014-01-01

    Quantitative (real-time) polymerase chain reaction (PCR) allows the measurement of relative organellar gene copy numbers as well as transcript abundance of individual mitochondrial or plastidial genes. Requiring only minute amounts of total DNA or RNA, the described method can replace traditional analyses like Southern or Northern hybridization which require large amounts of organellar nucleic acids and usually provide only semiquantitative data. Here we describe prerequisites, reaction conditions, and data analysis principles, which should be applicable for a wide range of plant species and experimental situations where comparative and precise determination of gene copy numbers or transcript abundance is requested. Sequences of amplification primers for qPCR of organellar genes from Arabidopsis are provided.

  17. Quantitative detection of Clostridium tyrobutyricum in milk by real-time PCR.

    Science.gov (United States)

    López-Enríquez, Lorena; Rodríguez-Lázaro, David; Hernández, Marta

    2007-06-01

    We developed a real-time PCR assay for the quantitative detection of Clostridium tyrobutyricum, which has been identified as the major causal agent of late blowing in cheese. The assay was 100% specific, with an analytical sensitivity of 1 genome equivalent in 40% of the reactions. The quantification was linear (R(2) > 0.9995) over a 5-log dynamic range, down to 10 genome equivalents, with a PCR efficiency of >0.946. With optimized detergent treatment and enzymatic pretreatment of the sample before centrifugation and nucleic acid extraction, the assay counted down to 300 C. tyrobutyricum spores, with a relative accuracy of 82.98 to 107.68, and detected as few as 25 spores in 25 ml of artificially contaminated raw or ultrahigh-temperature-treated whole milk.

  18. A fluorescence-based quantitative real-time PCR assay for accurate Pocillopora damicornis species identification

    Science.gov (United States)

    Thomas, Luke; Stat, Michael; Evans, Richard D.; Kennington, W. Jason

    2016-09-01

    Pocillopora damicornis is one of the most extensively studied coral species globally, but high levels of phenotypic plasticity within the genus make species identification based on morphology alone unreliable. As a result, there is a compelling need to develop cheap and time-effective molecular techniques capable of accurately distinguishing P. damicornis from other congeneric species. Here, we develop a fluorescence-based quantitative real-time PCR (qPCR) assay to genotype a single nucleotide polymorphism that accurately distinguishes P. damicornis from other morphologically similar Pocillopora species. We trial the assay across colonies representing multiple Pocillopora species and then apply the assay to screen samples of Pocillopora spp. collected at regional scales along the coastline of Western Australia. This assay offers a cheap and time-effective alternative to Sanger sequencing and has broad applications including studies on gene flow, dispersal, recruitment and physiological thresholds of P. damicornis.

  19. Evaluation of postmortem bacterial migration using culturing and real-time quantitative PCR.

    Science.gov (United States)

    Tuomisto, Sari; Karhunen, Pekka J; Vuento, Risto; Aittoniemi, Janne; Pessi, Tanja

    2013-07-01

    Postmortem bacteriology can be a valuable tool for evaluating deaths due to bacterial infection or for researching the involvement of bacteria in various diseases. In this study, time-dependent postmortem bacterial migration into liver, mesenteric lymph node, pericardial fluid, portal, and peripheral vein was analyzed in 33 autopsy cases by bacterial culturing and real-time quantitative polymerase chain reaction (RT-qPCR). None suffered or died from bacterial infection. According to culturing, pericardial fluid and liver were the most sterile samples up to 5 days postmortem. In these samples, multigrowth and staphylococci were not or rarely detected. RT-qPCR was more sensitive and showed higher bacterial positivity in all samples. Relative amounts of intestinal bacterial DNA (bifidobacteria, bacteroides, enterobacter, clostridia) increased with time. Sterility of blood samples was low during the studied time periods (1-7 days). The best postmortem microbiological sampling sites were pericardial fluid and liver up to 5 days after death.

  20. Haemotropic Mycoplasma Infection Revealed by Real-Time PCR in Specific Pathogen-Free Rats

    Directory of Open Access Journals (Sweden)

    Sashida Hinako

    2014-10-01

    Full Text Available The presence of Mycoplasma haemomuris (haemoplasma in blood samples collected from specific pathogen-free (SPF laboratory rats bred in Japan was reported. Its presence was examined in Fischer 344, Sprague-Dawley (SD, and Wistar rat strains of both sexes by real-time PCR. All strains were positive for M. haemomuris infection. The 16S rRNA gene of M. haemomuris strain detected in the animals was amplified using end-point PCR. Only the entire nucleotide sequence of 16S rRNA gene of a mycoplasma strain detected in SD rats was determined and compared to those of other haemoplasmas. Our investigations suggest a wide M. haemomuris infection among the SPF rats purchased from commercial breeders in Japan.

  1. Real-time PCR assay for detection and enumeration of Dekkera bruxellensis in wine.

    Science.gov (United States)

    Phister, Trevor G; Mills, David A

    2003-12-01

    Traditional methods to detect the spoilage yeast Dekkera bruxellensis from wine involve lengthy enrichments. To overcome this difficulty, we developed a quantitative real-time PCR method to directly detect and enumerate D. bruxellensis in wine. Specific PCR primers to D. bruxellensis were designed to the 26S rRNA gene, and nontarget yeast and bacteria common to the winery environment were not amplified. The assay was linear over a range of cell concentrations (6 log units) and could detect as little as 1 cell per ml in wine. The addition of large amounts of nontarget yeasts did not impact the efficiency of the assay. This method will be helpful to identify possible routes of D. bruxellensis infection in winery environments. Moreover, the time involved in performing the assay (3 h) should enable winemakers to more quickly make wine processing decisions in order to reduce the threat of spoilage by D. bruxellensis.

  2. Real-Time PCR Detection of Host-Mediated Cyanophage Gene Transcripts during Infection of a Natural Microcystis aeruginosa Population

    OpenAIRE

    Yoshida, Mitsuhiro; Yoshida, Takashi; Yoshida-Takashima, Yukari; Kashima, Aki; Hiroishi, Shingo

    2010-01-01

    The aim of this study was to develop a quantitative real-time reverse transcription-PCR (real-time RT-PCR) assay to detect and quantify mRNA of cyanophages within infected Microcystis aeruginosa cells in a freshwater pond. Laboratory-based data showed that the relative abundance of the cyanophage g91 mRNA within host cells increased before cyanophage numbers increased in culture. This transcriptional pattern indicated the kinetics of the viral infection suggesting the real-time RT-PCR method ...

  3. Evaluation of Three Real-Time PCR Methods for Detection of Salmonella from Cloves.

    Science.gov (United States)

    Tatavarthy, Aparna; Ali, Laila; Gill, Vikas; Hu, Lijun; Deng, Xiaohong; Adachi, Yoko; Rand, Hugh; Hammack, Thomas; Zhang, Guodong

    2017-06-01

    The purpose of the study was to evaluate three real-time PCR platforms for rapid detection of Salmonella from cloves and to compare three different DNA extraction methods. Six trials were conducted with two clove cultivars, Ceylon and Madagascar, and three Salmonella serotypes, Montevideo, Typhimurium, and Weltevreden. Each trial consisted of 20 test portions. The preenrichment cultures were used to perform PCR for comparison of the effectiveness of U.S. Food and Drug Administration, Pacific Regional Laboratory Southwest (FDA-PRLSW), Applied Biosystems Inc. (ABI) MicroSEQ, and GeneDisc platforms for detection of Salmonella. Three DNA extraction methods were used: standard extraction method for each PCR platform, boil preparation, and LyseNow food pathogen DNA extraction cards. The results from real-time PCR correlated well with FDA Bacteriological Analytical Manual culture assay results, with a wide range of cycle threshold (CT) values among the three PCR platforms for intended positive samples. The mean CT values for MicroSEQ (16.36 ± 2.78) were significantly lower than for PRLSW (20.37 ± 3.45) and GeneDisc (23.88 ± 2.90) (P < 0.0001). Pairwise comparisons between PCR platforms using different DNA extraction methods indicate that the CT values are inversely proportional to the relative DNA quantity (RDQ) yields by different platform-extraction combinations. The pairing of MicroSEQ and boil preparation generated the highest RDQ of 120 and the lowest average CT value of 14.48, whereas the pairing of GeneDisc and LyseNow generated the lowest RDQ of 0.18 and the highest average CT of 25.97. Boil preparation yielded higher RDQ than the other extraction methods for all three PCR platforms. Although the MicroSEQ platform generated the lowest CT values, its sensitivity was compromised by narrow separations between the positive and negative samples. The PRLSW platform generated the best segregation between positive and negative groups and is less likely to produce false

  4. Diagnostic efficacy of a real time-PCR assay for Chlamydia trachomatis infection in infertile women in north India

    Directory of Open Access Journals (Sweden)

    Benu Dhawan

    2014-01-01

    Full Text Available Background & objectives: Little is known about the prevalence of Chlamydia trachomatis infection in Indian women with infertility. To improve the diagnosis of C. trachomatis infection in developing countries, there is an urgent need to establish cost-effective molecular test with high sensitivity and specificity. This study was conducted to determine the diagnostic utility of a real time-PCR assay for detention of C. trachomatis infection in infertile women attending an infertility clinic in north India. The in house real time-PCR assay was also compared with a commercial real-time PCR based detection system. Methods: Endocervical swabs, collected from 200 infertile women were tested for C. trachomatis by three different PCR assays viz. in-house real time-PCR targeting the cryptic plasmid using published primers, along with omp1 gene and cryptic plasmid based conventional PCR assays. Specimens were also subjected to direct fluorescence assay (DFA and enzyme immunoassay (EIA Performance of in-house real time-PCR was compared with that of COBAS Taqman C. trachomatis Test, version 2.0 on all in-house real time-PCR positive sample and 30 consecutive negative samples. Results: C. trachomatis infection was found in 13.5 per cent (27/200 infertile women by in-house real time-PCR, 11.5 per cent (23/200 by cryptic plasmid and/or omp1 gene based conventional PCR, 9 per cent (18/200 by DFA and 6.5 per cent (7/200 by EIA. The in-house real time-PCR exhibited a sensitivity and specificity of 100 per cent, considering COBAS Taqman CT Test as the gold standard. The negative and positive predictive values of the in-house real time-PCR were 100 per cent. The in-house real time-PCR could detect as low as 10 copies of C. trachomatis DNA per reaction. Interpretation & conclusions: In-house real time-PCR targeting the cryptic plasmid of C. trachomatis exhibited an excellent sensitivity and specificity similar to that of COBAS Taqman CT Test, v2.0 for detection of C

  5. Hygienization by anaerobic digestion: comparison between evaluation by cultivation and quantitative real-time PCR.

    Science.gov (United States)

    Lebuhn, M; Effenberger, M; Garcés, G; Gronauer, A; Wilderer, P A

    2005-01-01

    In order to assess hygienization by anaerobic digestion, a comparison between evaluation by cultivation and quantitative real-time PCR (qPCR) including optimized DNA extraction and quantification was carried out for samples from a full-scale fermenter cascade (F1, mesophilic; F2, thermophilic; F3, mesophilic). The system was highly effective in inactivating (pathogenic) viable microorganisms, except for spore-formers. Conventionally performed cultivation underestimated viable organisms particularly in F2 and F3 by a factor of at least 10 as shown by data from extended incubation times, probably due to the rise of sublethally injured (active but not cultivable) cells. Incubation should hence be extended adequately in incubation-based hygiene monitoring of stressed samples, in order to minimize contamination risks. Although results from qPCR and cultivation agreed for the equilibrated compartments, considerably higher qPCR values were obtained for the fermenters. The difference probably corresponded to DNA copies from decayed cells that had not yet been degraded by the residual microbial activity. An extrapolation from qPCR determination to the quantity of viable organisms is hence not justified for samples that had been exposed to lethal stress.

  6. The sensitivity of real-time PCR amplification targeting invasive Salmonella serovars in biological specimens

    Directory of Open Access Journals (Sweden)

    Chau Tran

    2010-05-01

    Full Text Available Abstract Background PCR amplification for the detection of pathogens in biological material is generally considered a rapid and informative diagnostic technique. Invasive Salmonella serovars, which cause enteric fever, can be commonly cultured from the blood of infected patients. Yet, the isolation of invasive Salmonella serovars from blood is protracted and potentially insensitive. Methods We developed and optimised a novel multiplex three colour real-time PCR assay to detect specific target sequences in the genomes of Salmonella serovars Typhi and Paratyphi A. We performed the assay on DNA extracted from blood and bone marrow samples from culture positive and negative enteric fever patients. Results The assay was validated and demonstrated a high level of specificity and reproducibility under experimental conditions. All bone marrow samples tested positive for Salmonella, however, the sensitivity on blood samples was limited. The assay demonstrated an overall specificity of 100% (75/75 and sensitivity of 53.9% (69/128 on all biological samples. We then tested the PCR detection limit by performing bacterial counts after inoculation into blood culture bottles. Conclusions Our findings corroborate previous clinical findings, whereby the bacterial load of S. Typhi in peripheral blood is low, often below detection by culture and, consequently, below detection by PCR. Whilst the assay may be utilised for environmental sampling or on differing biological samples, our data suggest that PCR performed directly on blood samples may be an unsuitable methodology and a potentially unachievable target for the routine diagnosis of enteric fever.

  7. Detection of Brettanomyces spp. in red wines using real-time PCR.

    Science.gov (United States)

    Tofalo, Rosanna; Schirone, Maria; Corsetti, Aldo; Suzzi, Giovanna

    2012-09-01

    The question if the "Brett character" is a favorable wine attribute is one of the most controversial issues and it is currently addressed by many researches. Actually, the presence of Brettanomyces/Dekkera in wine during barrel aging is often associated to detrimental organoleptic characteristics depending on the release of volatile phenols (for example, 4-ethylphenol and 4-ethylguaiacol); for that reason the possibility to rapidly detect the yeast at the early stage of wine production could allow preventive actions to reduce wine spoilage. In this work, 25 and 5 samples from conventional and organic vineyards, respectively, all suspected to be spoiled by Brettanomyces/Dekkera spp., were analyzed using both culture-dependent and culture-independent techniques. In particular, a DNA extraction protocol and a real-time quantitative PCR (qPCR) assay to directly detect and quantify B. bruxellensis were optimized. Results showed that B. bruxellensis was present in 22 of 30 samples, ranging from 10 to 10(4) CFU/mL, lower values being found in organic wines (10 to 10(2) CFU/mL). Overall, qPCR was proved to be a useful and valuable wine control system, since 12 samples were recorded as positive for yeast presence when analyzed by qPCR and negative in case of plate count analyses. Brettanomyces cells were detected using a qPCR method, optimized in this study, which allows to obtain results quickly. © 2012 Institute of Food Technologists®

  8. A Low-Cost and Fast Real-Time PCR System Based on Capillary Convection.

    Science.gov (United States)

    Qiu, Xianbo; Ge, Shengxiang; Gao, Pengfei; Li, Ke; Yang, Yongliang; Zhang, Shiyin; Ye, Xiangzhong; Xia, Ningshao; Qian, Shizhi

    2017-02-01

    A low-cost and fast real-time PCR system in a pseudo-isothermal manner with disposable capillary tubes based on thermal convection for point-of-care diagnostics is developed and tested. Once stable temperature gradient along the capillary tube has been established, a continuous circulatory flow or thermal convection inside the capillary tube will repeatedly transport PCR reagents through temperature zones associated with the DNA denaturing, annealing, and extension stages of the reaction. To establish stable temperature gradient along the capillary tube, a dual-temperature heating strategy with top and bottom heaters is adopted here. A thermal waveguide is adopted for precise maintenance of the temperature of the top heater. An optimized optical network is developed for monitoring up to eight amplification units for real-time fluorescence detection. The system performance was demonstrated with repeatable detection of influenza A (H1N1) virus nucleic acid targets with a limit of detection of 1.0 TCID50/mL within 30 min.

  9. Detection of Mycobacterium tuberculosis resistance mutations to rifampin and isoniazid by real-time PCR

    Directory of Open Access Journals (Sweden)

    Hristea A

    2010-01-01

    Full Text Available Objective: The objective of our study was to evaluate the use of a real-time polymerase chain reaction (PCR-based technique for the prediction of phenotypic resistance of Mycobacterium tuberculosis. Materials and Methods: We tested 67 M tuberculosis strains (26 drug resistant and 41 drug susceptible using a method recommended for the LightCycler platform. The susceptibility testing was performed by the absolute concentration method. For rifampin resistance, two regions of the rpoB gene were targeted, while for identification of isoniazid resistance, we searched for mutations in katG and inhA genes. Results: The sensitivity and specificity of this method for rapid detection of mutations for isoniazid resistance were 96% (95% CI: 88% to 100% and 95% (95% CI: 89% to 100%, respectively. For detection of rifampin resistance, the sensitivity and specificity were 92% (95% CI: 81% to 100% and 74% (95% CI: 61% to 87%, respectively. The main isoniazid resistance mechanism identified in our isolates is related to changes in the katG gene that encodes catalase. We found that for rifampin resistance the concordance between the predicted and observed phenotype was less than satisfactory. Conclusions: Using this method, the best accuracy for genotyping compared with phenotypic resistance testing was obtained for detecting isoniazid resistance mutations. Although real-time PCR assay may be a valuable diagnostic tool, it is not yet completely satisfactory for detection of drug resistance mutations in M tuberculosis.

  10. Species identification of white false hellebore (Veratrum album subsp. oxysepalum) using real-time PCR.

    Science.gov (United States)

    Kikkawa, Hitomi S; Tsuge, Kouichiro; Kubota, Satoshi; Aragane, Masako; Ohta, Hikoto; Sugita, Ritsuko

    2017-03-20

    Food poisoning is frequently caused by the accidental ingestion of toxic plants that possess strong morphological similarities to edible plants. False helleborine (Veratrum album) is one of the most common plants involved in such accidents. In cases of poisoning by toxic plants, rapid and accurate identification, usually based on the morphological or chemical analysis of plant parts, is required for appropriate medical treatment or forensic investigation. However, morphological examinations require experience in systematic botany because the samples are fragmentary, and chemical analysis of natural compounds can be difficult. In this study, we developed a TaqMan real-time PCR method using trnH-psbA and trnL-trnF that could be carried out in 30-60min. The lower detection limit was less than 10pg of DNA and the primer sets were specific to V. album and Veratrum stamineum. Mixed samples, cooked samples, and simulated gastric contents were successfully identified, and a multiplex assay of two regions was also possible. These results indicate that the TaqMan real-time PCR analysis is a very effective method to detect small samples of V. album and V. stamineum accurately and rapidly in poisoning cases.

  11. Selection of reference genes for quantitative real-time PCR in bovine preimplantation embryos

    Directory of Open Access Journals (Sweden)

    Van Zeveren Alex

    2005-12-01

    Full Text Available Abstract Background Real-time quantitative PCR is a sensitive and very efficient technique to examine gene transcription patterns in preimplantation embryos, in order to gain information about embryo development and to optimize assisted reproductive technologies. Critical to the succesful application of real-time PCR is careful assay design, reaction optimization and validation to maximize sensitivity and accuracy. In most of the studies published GAPD, ACTB or 18S rRNA have been used as a single reference gene without prior verification of their expression stability. Normalization of the data using unstable controls can result in erroneous conclusions, especially when only one reference gene is used. Results In this study the transcription levels of 8 commonly used reference genes (ACTB, GAPD, Histone H2A, TBP, HPRT1, SDHA, YWHAZ and 18S rRNA were determined at different preimplantation stages (2-cell, 8-cell, blastocyst and hatched blastocyst in order to select the most stable genes to normalize quantitative data within different preimplantation embryo stages. Conclusion Using the geNorm application YWHAZ, GAPD and SDHA were found to be the most stable genes across the examined embryonic stages, while the commonly used ACTB was shown to be highly regulated. We recommend the use of the geometric mean of those 3 reference genes as an accurate normalization factor, which allows small expression differences to be reliably measured.

  12. Using Real-Time PCR as a tool for monitoring the authenticity of commercial coffees.

    Science.gov (United States)

    Ferreira, Thiago; Farah, Adriana; Oliveira, Tatiane C; Lima, Ivanilda S; Vitório, Felipe; Oliveira, Edna M M

    2016-05-15

    Coffee is one of the main food products commercialized in the world. Its considerable market value among food products makes it susceptible to adulteration, especially with cereals. Therefore, the objective of this study was to develop a method based on Real-Time Polymerase Chain Reaction (PCR) for detection of cereals in commercial ground roast and soluble coffees. After comparison with standard curves obtained by serial dilution of DNA extracted from barley, corn and rice, the method was sensitive and specific to quantify down to 0.6 pg, 14 pg and 16 pg of barley, corn and rice DNA, respectively. To verify the applicability of the method, 30 commercial samples obtained in different countries were evaluated and those classified as gourmets or superior did not present the tested cereals DNA. However, barley was detected in various traditional (cheaper) samples from South America. In addition, corn and rice were also detected in different samples. Real-Time PCR showed to be suitable for detection of food adulterants in commercial ground roast and soluble coffees.

  13. Effect of ionizing radiation on the quantitative detection of Salmonella using real-time PCR

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Sangyong; Jung, Jinwoo [Radiation Research Center for Biotechnology, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of); Kim, Minjeong; Ryu, Sangryeol [Department of Food and Animal Biotechnology, School of Agricultural Biotechnology, Center for Agricultural Biomaterials, Seoul National University, Seoul 151-921 (Korea, Republic of); Kim, Dongho [Radiation Research Center for Biotechnology, Korea Atomic Energy Research Institute, Jeongeup 580-185 (Korea, Republic of)], E-mail: fungikim@kaeri.re.kr

    2008-09-15

    Food irradiation is an economically viable technology for inactivating foodborne pathogens, but irradiation can mask pathogens in unhygienically prepared food. The aim of this study was to investigate the effect of irradiation treatment on the detection of Salmonella using real-time PCR. Three commercially available kits were tested, of which the InstaGene Matrix procedure was most effective in preparing template DNA from Salmonella exposed to radiation in broth culture. The minimum level of detection by real-time PCR combined with InstaGene Matrix was 3 log units of Salmonella per milliliter. However, when pure cultures of Salmonella were irradiated at 3 and 5 kGy, the cycle threshold (C{sub T}) increased 1-1.5-fold compared to irradiation at 0 and 1 kGy. This indicated that irradiation treatment may result in an underestimation of bacterial counts due to radiation-induced DNA lesions. We also compared C{sub T} values in inoculated chicken homogenates before and after irradiation, which in this model caused a 1.3-3.3-fold underestimation of bacterial counts with respect to irradiation dose.

  14. A real time PCR assay on blood for diagnosis of invasive candidiasis in immunocompromised patient

    Directory of Open Access Journals (Sweden)

    Mohsen Ashrafi

    2015-01-01

    Results: From 2009 to 2011, 72 patients with hematologic malignancies and bone marrow transplant recipients were evaluated for IC. The female to male ratio was 27:45; the mean age was 32.1 years. The most common malignancy in this patient was acute myeloid leukemia (AML (27.8% and acute lymphoblastic leukemia (ALL (26.4%. Out of 72 patients, 11 patients (15.3% had positive real time PCR /probe results. Based on the melting temperature (Tm analysis, 5 (45.4% C. krusei, 3 (27.2% C. tropicalis, 2 (18.1% C. parapsilosis and 1 C. albicans (9% were identified. According to the revised EORTC / MSG, 1 patient (9% and 10 patients (91% were defined as proven and possible groups of IC, respectively. The mortality rate in proven and possible IC patient was found 54.5%. Conclusion: The established Real-time PCR/FRET probe assay is an appropriate diagnostic tool for the detection of Candida species DNA and the management of patients suffering from hematologic malignancies and bone marrow recipient are at risk for IC.

  15. Quantifying anti-HBV effect of targeted ribonuclease by real-time fluorescent PCR

    Institute of Scientific and Technical Information of China (English)

    Jun Liu; Ying-Hui Li; Jin Ding; Wei-Dong Gong; Cai-Fang Xue; Ya Zhao; Yu-Xiao Huang

    2004-01-01

    AIM: To quantify the inhibition of HBV replication by targeted ribonuclease by using real-time fluorescent PCR.METHODS: Targeted ribonuclease was introduced into 2.2.15cells by liposome-mediated transfection or HIV-TAT mediated protein transduction. Forty-eight hours after the transfection and 24 h after the transduction, supernatants of 2.2.15 cells were collected and HBV DNA in the supernatants was quantified by real-time fluorescent PCR with a commercial kit.RESULTS: HBV DNA concentrations in the supernatants of2.2.15 cells transfected or transducted with targeted ribonuclease were 4.9±2.4×108 copies/L and 8.3±4.0×108copies/L, respectively. Compared with controls, transfection or transduction of targeted ribonuclease reduced HBV DNA concentration in the supernatants of 2.2.15 cells by 90.4%and 90.1%, respectively (P<0.05).CONCLUSION: Targeted ribonuclease can inhibit HBV replication in 2.2.15 cells.

  16. Novel methods of cytokine detection: Real-time PCR, ELISPOT, and intracellular cytokine staining

    Directory of Open Access Journals (Sweden)

    Eliza Turlej

    2009-05-01

    Full Text Available Cytokines are small hormone-like proteins that play important roles in immune system control. Cytokines regulate the proliferation and differentiation of cells and hematopoiesis and act as mediators in the inflammatory reaction. Changes in cytokine levels are found in many diseases, such as sepsis, bowel inflammatory disease, autoimmune diseases, as well as graft-versus-host disease. Cytokines levels can be detected using in vivo, in vitro, and ex vivo techniques. The level of cytokine produced can be measured by immunoenzymatic test (ELISA in supernatant after cell culture with the addition of stimulant and in plasma by techniques that measure the level of cytokine secretion in cells (e.g. immunohistochemical staining, ELISPOT, and intracellular cytokine staining, and by molecular biological methods (RPA, real-time PCR, in situ hybridization, and Northern blot. Detection of cytokine mRNA in tissues is useful in the direct determination of heterogenic populations of cytokine-producing cells. Nowadays the most frequently used methods for measuring cytokine level are ELISPOT, intracellular cytokine staining with flow cytometry detection, and real-time PCR. These methods have an important clinical role in vaccine efficacy, in viral, bacterial, and verminous diagnostics, and in determining the efficacy of cancer treatment.

  17. Ultrasensitive quantitation of human papillomavirus type 16 E6 oncogene sequences by nested real time PCR

    Directory of Open Access Journals (Sweden)

    López-Revilla Rubén

    2010-05-01

    Full Text Available Abstract Background We have developed an ultrasensitive method based on conventional PCR preamplification followed by nested amplification through real time PCR (qPCR in the presence of the DNA intercalating agent EvaGreen. Results Amplification mixtures calibrated with a known number of pHV101 copies carrying a 645 base pair (bp-long insert of the human papillomavirus type 16 (HPV16 E6 oncogene were used to generate the E6-1 amplicon of 645 bp by conventional PCR and then the E6-2 amplicon of 237 bp by nested qPCR. Direct and nested qPCR mixtures for E6-2 amplification corresponding to 2.5 × 102-2.5 × 106 initial pHV101 copies had threshold cycle (Ct values in the ranges of 18.7-29.0 and 10.0-25.0, respectively. The Ct of qPCR mixtures prepared with 1/50 volumes of preamplified mixtures containing 50 ng of DNA of the SiHa cell line (derived from an invasive cervical cancer with one HPV16 genome per cell was 19.9. Thermal fluorescence extinction profiles of E6-2 amplicons generated from pHV101 and SiHa DNA were identical, with a peak at 85.5°C. Conclusions Our method based on conventional preamplification for 15 cycles increased 10,750 times the sensitivity of nested qPCR for the quantitation of the E6 viral oncogene and confirmed that the SiHa cell line contains one E6-HPV16 copy per cell.

  18. Real-Time PCR Method for Detection of Salmonella spp. in Environmental Samples.

    Science.gov (United States)

    Kasturi, Kuppuswamy N; Drgon, Tomas

    2017-07-15

    The methods currently used for detecting Salmonella in environmental samples require 2 days to produce results and have limited sensitivity. Here, we describe the development and validation of a real-time PCR Salmonella screening method that produces results in 18 to 24 h. Primers and probes specific to the gene invA, group D, and Salmonella enterica serovar Enteritidis organisms were designed and evaluated for inclusivity and exclusivity using a panel of 329 Salmonella isolates representing 126 serovars and 22 non-Salmonella organisms. The invA- and group D-specific sets identified all the isolates accurately. The PCR method had 100% inclusivity and detected 1 to 2 copies of Salmonella DNA per reaction. Primers specific for Salmonella-differentiating fragment 1 (Sdf-1) in conjunction with the group D set had 100% inclusivity for 32 S Enteritidis isolates and 100% exclusivity for the 297 non-Enteritidis Salmonella isolates. Single-laboratory validation performed on 1,741 environmental samples demonstrated that the PCR method detected 55% more positives than the Vitek immunodiagnostic assay system (VIDAS) method. The PCR results correlated well with the culture results, and the method did not report any false-negative results. The receiver operating characteristic (ROC) analysis documented excellent agreement between the results from the culture and PCR methods (area under the curve, 0.90; 95% confidence interval of 0.76 to 1.0) confirming the validity of the PCR method.IMPORTANCE This validated PCR method detects 55% more positives for Salmonella in half the time required for the reference method, VIDAS. The validated PCR method will help to strengthen public health efforts through rapid screening of Salmonella spp. in environmental samples.

  19. Comparison between Conventional and Real-Time PCR Assays for Diagnosis of Visceral Leishmaniasis

    Directory of Open Access Journals (Sweden)

    Mariana R. Pereira

    2014-01-01

    Full Text Available The diagnosis of visceral leishmaniasis (VL is a challenging issue and several studies worldwide have evaluated the different tools to reach a diagnostic solution. The polymerase chain reaction (PCR has proven to be effective in detecting the genome of Leishmania species in different biological samples. In this study, we compared the conventional PCR and real-time PCR using the Sybr Green system and their application in molecular diagnosis of visceral leishmaniasis in peripheral blood as a biological sample. The genus-specific conserved region of kinetoplast DNA (kDNA was the target of amplification. We studied 30 samples from patients with suspect of visceral leishmaniasis who were treated by the Medical Clinic of Santa Casa de Belo Horizonte Hospital, Brazil. Among the samples studied, 19 had a confirmed diagnosis for VL by serology and/or by clinical findings. Among these 19 samples, 63% (n=12 presented positive results for serology and 79% (n=15 positive results in both PCR methodologies. This fact suggests that the PCR technique can assist in the diagnosis of visceral leishmaniasis in patients who do not have detectable antibodies by serology but can present the genome of the parasite circulating in whole blood. Also, it was possible to observe that there was conformity between the results of the techniques of cPCR and qPCR using the Sybr Green system in 100% of samples analyzed. These data suggest that both PCR techniques were equally effective for detection of the genome of the parasite in the patient’s blood.

  20. Comparison between Conventional and Real-Time PCR Assays for Diagnosis of Visceral Leishmaniasis

    Science.gov (United States)

    Pereira, Mariana R.; Rocha-Silva, Fabiana; Graciele-Melo, Cidiane; Lafuente, Camila R.; Magalhães, Telcia; Caligiorne, Rachel B.

    2014-01-01

    The diagnosis of visceral leishmaniasis (VL) is a challenging issue and several studies worldwide have evaluated the different tools to reach a diagnostic solution. The polymerase chain reaction (PCR) has proven to be effective in detecting the genome of Leishmania species in different biological samples. In this study, we compared the conventional PCR and real-time PCR using the Sybr Green system and their application in molecular diagnosis of visceral leishmaniasis in peripheral blood as a biological sample. The genus-specific conserved region of kinetoplast DNA (kDNA) was the target of amplification. We studied 30 samples from patients with suspect of visceral leishmaniasis who were treated by the Medical Clinic of Santa Casa de Belo Horizonte Hospital, Brazil. Among the samples studied, 19 had a confirmed diagnosis for VL by serology and/or by clinical findings. Among these 19 samples, 63% (n = 12) presented positive results for serology and 79% (n = 15) positive results in both PCR methodologies. This fact suggests that the PCR technique can assist in the diagnosis of visceral leishmaniasis in patients who do not have detectable antibodies by serology but can present the genome of the parasite circulating in whole blood. Also, it was possible to observe that there was conformity between the results of the techniques of cPCR and qPCR using the Sybr Green system in 100% of samples analyzed. These data suggest that both PCR techniques were equally effective for detection of the genome of the parasite in the patient's blood. PMID:24689047

  1. Validation of Reference Genes for Quantitative Real-Time PCR in Laodelphax striatellus

    Institute of Scientific and Technical Information of China (English)

    HE Xiu-ting; LIU Cheng-cheng; LI Zhao-qun; ZHANG Zan; LI Guo-qing; LI Fei; DONG Shuang-lin

    2014-01-01

    The normalization of quantitative real-time PCR (qPCR) is important to obtain accurate gene expression data, and the most common method for qPCR normalization is to use reference genes. However, reference genes can be regulated under different conditions. qPCR has recently been used for gene expression study in Laodelphax striatellus, but there is no study on validation of the reference genes. In this study, ifve new housekeeping genes (LstrTUB1, LstrTUB2, LstrTUB3, LstrARF and LstrRPL9) in L. striatellus were cloned and deposited in the GenBank with accession numbers of JF728809, JF728810, JF728811, JF728807 and JF728806, respectively. Furthermore, mRNA expressions of the five genes and β-actin were measured by qPCR with insect samples of different instar at nymph stage, and the expression stabilities were determined by the software geNorm and NormFinder. As a result, ARF and RPL9 were consistently more stable thanβ-actin, while three TUB genes were less stable than β-actin. To determine the optimal number of reference genes used in qPCR, a pairwise variations analysis by geNorm indicated that two references ARF and RPL9 were required to obtain the accurate quantiifcation. These results were further conifrmed by the validation qPCR experiment with chitinase gene as the target gene, in which the standard error of the mRNA quantiifcation by using binary reference ARF-RPL9 was much lower than those by ARF, RPL9 orβ-actin alone. Taken together, our study suggested that the combination of ARF-RPL9 could replaceβ-actin as the reference genes for qPCR in L. striatellus.

  2. Acetobacter aceti fast identification by Real Time PCR in spoiled wine samples

    Directory of Open Access Journals (Sweden)

    Attila Kántor

    2014-11-01

    Full Text Available Wine is a beverage that made from grape berries. However, without beneficial bacteria, we would not produce good wine. But very often wines contain acetic acid bacteria, which are undesirable in winemaking process. Acetic acid bacteria as known as a vinegar bacteria are Gram-negative, aerobic, rod-shaped and ubiquitous bacteria. This study was focused on species of acetic acid bacteria, specifically Acetobacter aceti that make spoilage in wine.The aim of our study was the identification of Acetobacter aceti in spoiled red wine samples, with plate dilution method on agar plates and using sensitive Real-time PCR (qPCR method. We cultivated Acetobacter aceti on GYC agar at 30°C, 48h. The one of main objective in the present work was the test fast, sensitive and reliable technique such as quantitative Real-time PCR and detecting the presence of Acetobacter aceti in wine samples with positive Acetobacteraceti control on amplification plot and melting curve. The next objective before  qPCR analysis was DNA extraction from wine samples incubated for one week at 28°C aerobically. We used five different red wine samples for this experiment: Alibernet 2013, Blaufränkisch 2013, Cabernet Sauvignon 2013, Dunaj 2012 and Saint-Laurent 2012. Next we extracted DNA from wine samples and from pure Acetobacter aceti CCM 3620T strain purchased from Czech collection of microorganisms in Brno. Susceptibility ofAcetobacter aceti was varied in different isolates from 102 to 107 CFU.mL-1. The number of Acetobacter cells on GYC medium ranged from 4.05 to 4.83log CFU.mL-1 in differentwine samples.The higher number of Acetobacter cells (4.83 log CFU.mL-1 was found in Cabernet Sauvignon 2013 wine.

  3. Droplet digital polymerase chain reaction (PCR) outperforms real-time PCR in the detection of environmental DNA from an invasive fish species.

    Science.gov (United States)

    Doi, Hideyuki; Takahara, Teruhiko; Minamoto, Toshifumi; Matsuhashi, Saeko; Uchii, Kimiko; Yamanaka, Hiroki

    2015-05-01

    Environmental DNA (eDNA) has been used to investigate species distributions in aquatic ecosystems. Most of these studies use real-time polymerase chain reaction (PCR) to detect eDNA in water; however, PCR amplification is often inhibited by the presence of organic and inorganic matter. In droplet digital PCR (ddPCR), the sample is partitioned into thousands of nanoliter droplets, and PCR inhibition may be reduced by the detection of the end-point of PCR amplification in each droplet, independent of the amplification efficiency. In addition, real-time PCR reagents can affect PCR amplification and consequently alter detection rates. We compared the effectiveness of ddPCR and real-time PCR using two different PCR reagents for the detection of the eDNA from invasive bluegill sunfish, Lepomis macrochirus, in ponds. We found that ddPCR had higher detection rates of bluegill eDNA in pond water than real-time PCR with either of the PCR reagents, especially at low DNA concentrations. Limits of DNA detection, which were tested by spiking the bluegill DNA to DNA extracts from the ponds containing natural inhibitors, found that ddPCR had higher detection rate than real-time PCR. Our results suggest that ddPCR is more resistant to the presence of PCR inhibitors in field samples than real-time PCR. Thus, ddPCR outperforms real-time PCR methods for detecting eDNA to document species distributions in natural habitats, especially in habitats with high concentrations of PCR inhibitors.

  4. A multiplex real-time PCR panel assay for simultaneous detection and differentiation of 12 common swine viruses.

    Science.gov (United States)

    Shi, Xiju; Liu, Xuming; Wang, Qin; Das, Amaresh; Ma, Guiping; Xu, Lu; Sun, Qing; Peddireddi, Lalitha; Jia, Wei; Liu, Yanhua; Anderson, Gary; Bai, Jianfa; Shi, Jishu

    2016-10-01

    Mixed infection with different pathogens is common in swine production systems especially under intensive production conditions. Quick and accurate detection and differentiation of different pathogens are necessary for epidemiological surveillance, disease management and import and export controls. In this study, we developed and validated a panel of multiplex real-time PCR/RT-PCR assays composed of four subpanels, each detects three common swine pathogens. The panel detects 12 viruses or viral serotypes, namely, VSV-IN, VSV-NJ, SVDV, CSFV, ASFV, FMDV, PCV2, PPV, PRV, PRRSV-NA, PRRSV-EU and SIV. Correlation coefficients (R(2)) and PCR amplification efficiencies of all singular and triplex real-time PCR reactions are within the acceptable range. Comparison between singular and triplex real-time PCR assays of each subpanel indicates that there is no significant interference on assay sensitivities caused by multiplexing. Specificity tests on 226 target clinical samples or 4 viral strains and 91 non-target clinical samples revealed that the real-time PCR panel is 100% specific, and there is no cross amplification observed. The limit of detection of each triplex real-time PCR is less than 10 copies per reaction for DNA, and less than 16 copies per reaction for RNA viruses. The newly developed multiplex real-time PCR panel also detected different combinations of co-infections as confirmed by other means of detections.

  5. A method for accurate detection of genomic microdeletions using real-time quantitative PCR

    Directory of Open Access Journals (Sweden)

    Bassett Anne S

    2005-12-01

    Full Text Available Abstract Background Quantitative Polymerase Chain Reaction (qPCR is a well-established method for quantifying levels of gene expression, but has not been routinely applied to the detection of constitutional copy number alterations of human genomic DNA. Microdeletions or microduplications of the human genome are associated with a variety of genetic disorders. Although, clinical laboratories routinely use fluorescence in situ hybridization (FISH to identify such cryptic genomic alterations, there remains a significant number of individuals in which constitutional genomic imbalance is suspected, based on clinical parameters, but cannot be readily detected using current cytogenetic techniques. Results In this study, a novel application for real-time qPCR is presented that can be used to reproducibly detect chromosomal microdeletions and microduplications. This approach was applied to DNA from a series of patient samples and controls to validate genomic copy number alteration at cytoband 22q11. The study group comprised 12 patients with clinical symptoms of chromosome 22q11 deletion syndrome (22q11DS, 1 patient trisomic for 22q11 and 4 normal controls. 6 of the patients (group 1 had known hemizygous deletions, as detected by standard diagnostic FISH, whilst the remaining 6 patients (group 2 were classified as 22q11DS negative using the clinical FISH assay. Screening of the patients and controls with a set of 10 real time qPCR primers, spanning the 22q11.2-deleted region and flanking sequence, confirmed the FISH assay results for all patients with 100% concordance. Moreover, this qPCR enabled a refinement of the region of deletion at 22q11. Analysis of DNA from chromosome 22 trisomic sample demonstrated genomic duplication within 22q11. Conclusion In this paper we present a qPCR approach for the detection of chromosomal microdeletions and microduplications. The strategic use of in silico modelling for qPCR primer design to avoid regions of repetitive

  6. Development and calibration of real-time PCR for quantification of airborne microorganisms in air samples

    Science.gov (United States)

    An, Hey Reoun; Mainelis, Gediminas; White, Lori

    This manuscript describes the coupling of bioaerosol collection and the use of real-time PCR (RT-PCR) to quantify the airborne bacteria. The quantity of collected bacteria determined by RT-PCR is compared with conventional quantification techniques, such as culturing, microscopy and airborne microorganism counting by using optical particle counter (OPC). Our data show that an experimental approach used to develop standard curves for use with RT-PCR is critical for accurate sample quantification. Using universal primers we generated 12 different standard curves which were used to quantify model organism Escherichia coli (Migula) Catellani from air samples. Standard curves prepared using a traditional approach, where serially diluted genomic DNA extracted from pure cultured bacteria were used in PCR reaction as a template DNA yielded significant underestimation of sample quantities compared to airborne microorganism concentration as measured by an OPC. The underestimation was especially pronounced when standard curves were built using colony forming units (CFUs). In contrast, the estimate of cell concentration in an air sample by RT-PCR was more accurate (˜60% compared to the airborne microorganism concentration) when the standard curve was built using aerosolized E. coli. The accuracy improved even further (˜100%) when air samples used to build the standard curves were diluted first, then the DNA extracted from each dilution was amplified by the RT-PCR—to mimic the handling of air samples with unknown and possibly low concentration. Therefore, our data show that standard curves used for quantification by RT-PCR needs to be prepared using the same environmental matrix and procedures as handling of the environmental sample in question. Reliance on the standard curves generated with cultured bacterial suspension (a traditional approach) may lead to substantial underestimation of microorganism quantities in environmental samples.

  7. Correlation of Real Time PCR Cycle Threshold Cut-Off with Bordetella pertussis Clinical Severity.

    Directory of Open Access Journals (Sweden)

    Shelly Bolotin

    Full Text Available Bordetella pertussis testing performed using real-time polymerase chain reaction (RT-PCR is interpreted based on a cycle threshold (Ct value. At Public Health Ontario Laboratories (PHOL, a Ct value <36 is reported as positive, and Ct values ≥36 and <40 are reported as indeterminate. PHOL reported indeterminate results to physicians and public health units until May 2012, after which these results were only reported to physicians. We investigated the association between Ct value and disease symptom and severity to examine the significance of indeterminate results clinically, epidemiologically and for public health reporting. B. pertussis positive and indeterminate RT-PCR results were linked to pertussis cases reported in the provincial Integrated Public Health Information System (iPHIS, using deterministic linkage. Patients with positive RT-PCR results had a lower median age of 10.8 years compared to 12.0 years for patients with indeterminate results (p = 0.24. Hospitalized patients had significantly lower Ct values than non-hospitalized patients (median Ct values of 20.7 vs. 31.6, p<0.001. The proportion of patients reporting the most indicative symptoms of pertussis did not differ between patients with positive vs. indeterminate RT-PCR results. Taking the most indicative symptoms of pertussis as the gold-standard, the positive predictive value of the RT-PCR test was 68.1%. RT-PCR test results should be interpreted in the context of the clinical symptoms, age, vaccination status, prevalence, and other factors. Further information on interpretation of indeterminate RT-PCR results may be needed, and the utility of reporting to public health practitioners should be re-evaluated.

  8. Multiplex real-time PCR assay for rapid detection of methicillin-resistant staphylococci directly from positive blood cultures.

    Science.gov (United States)

    Wang, Hye-Young; Kim, Sunghyun; Kim, Jungho; Park, Soon-Deok; Uh, Young; Lee, Hyeyoung

    2014-06-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is the most prevalent cause of bloodstream infections (BSIs) and is recognized as a major nosocomial pathogen. This study aimed to evaluate a newly designed multiplex real-time PCR assay capable of the simultaneous detection of mecA, S. aureus, and coagulase-negative staphylococci (CoNS) in blood culture specimens. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays (M&D, Republic of Korea) use the TaqMan probes 16S rRNA for Staphylococcus spp., the nuc gene for S. aureus, and the mecA gene for methicillin resistance. The detection limit of the multiplex real-time PCR assay was 10(3) CFU/ml per PCR for each gene target. The multiplex real-time PCR assay was evaluated using 118 clinical isolates from various specimen types and a total of 350 positive blood cultures from a continuous monitoring blood culture system. The results obtained with the multiplex real-time PCR assay for the three targets were in agreement with those of conventional identification and susceptibility testing methods except for one organism. Of 350 positive bottle cultures, the sensitivities of the multiplex real-time PCR kit were 100% (166/166 cultures), 97.2% (35/36 cultures), and 99.2% (117/118 cultures) for the 16S rRNA, nuc, and mecA genes, respectively, and the specificities for all three targets were 100%. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays are very useful for the rapid accurate diagnosis of staphylococcal BSIs. In addition, the Real-MRSA and Real-MRCoNS multiplex real-time PCR assays could have an important impact on the choice of appropriate antimicrobial therapy, based on detection of the mecA gene.

  9. Evaluation of real-time PCR for Strongyloides stercoralis and hookworm as diagnostic tool in asymptomatic schoolchildren in Cambodia.

    Science.gov (United States)

    Schär, Fabian; Odermatt, Peter; Khieu, Virak; Panning, Marcus; Duong, Socheat; Muth, Sinuon; Marti, Hanspeter; Kramme, Stefanie

    2013-05-01

    Diagnosis of soil-transmitted helminths such as Strongyloides stercoralis and hookworms (Ancylostoma duodenale and Necator americanus) is challenging due to irregular larval and egg output in infected individuals and insensitive conventional diagnostic procedures. Sensitive novel real-time PCR assays have been developed. Our study aimed to evaluate the real-time PCR assays as a diagnostic tool for detection of Strongyloides spp. and hookworms in a random stool sample of 218 asymptomatic schoolchildren in Cambodia. Overall prevalence of 17.4% (38/218) and 34.9% (76/218) were determined by real-time PCR for S. stercoralis and hookworms, respectively. Sensitivity and specificity of S. stercoralis specific real-time PCR as compared to the combination of Baermann/Koga Agar as gold standard were 88.9% and 92.7%, respectively. For hookworm specific real-time PCR a sensitivity of 78.9% and specificity of 78.9% were calculated. Co-infections were detectable by PCR in 12.8% (28/218) of individuals. S. stercoralis real-time PCR applied in asymptomatic cases showed a lower sensitivity compared to studies undertaken with symptomatic patients with the same molecular tool, yet it proved to be a valid supplement in the diagnosis of STH infection in Cambodia.

  10. Detection of stable reference genes for real-time PCR analysis in schizophrenia and bipolar disorder.

    Science.gov (United States)

    Silberberg, Gilad; Baruch, Kuti; Navon, Ruth

    2009-08-15

    Gene expression studies using postmortem human brain tissue are a common tool for studying the etiology of psychiatric disorders. Quantitative real-time PCR (qPCR) is an accurate and sensitive technique used for gene expression analysis in which the expression level is quantified by normalization to one or more reference genes. Therefore, accurate data normalization is critical for validating results obtained by qPCR. This study aimed to identify genes that may serve as reference in postmortem dorsolateral-prefrontal cortices (Brodmann's area 46) of schizophrenics, bipolar disorder (BPD) patients, and control subjects. In the exploratory stage of the analysis, samples of four BPD patients, two schizophrenics, and two controls were quantified using the TaqMan Low Density Array endogenous control panel, containing assays for 16 commonly used reference genes. In the next stage, six of these genes (TFRC, RPLP0, ACTB, POLR2a, B2M, and GAPDH) were quantified by qPCR in 12 samples of each clinical group. Expressional stability of the genes was determined by GeNorm and NormFinder. TFRC and RPLP0 were the most stably expressed genes, whereas the commonly used 18S, POLR2a, and GAPDH were the least stable. This report stresses the importance of examining expressional stability of candidate reference genes in the specific sample collection to be analyzed.

  11. Methylation-sensitive restriction enzyme nested real time PCR, a potential approach for sperm DNA identification.

    Science.gov (United States)

    Bai, Lijuan; Yan, Peng; Cao, Ximei; Jia, Linna; Zhang, Ce; Guo, Dawei

    2015-08-01

    Mammal H19 gene is an imprinting gene in which the paternal allele is silenced. On H19 imprinting control region (ICR), one of the mechanisms regulating the paternal allelic specific silence is DNA methylation in somatic cells throughout the individual's whole life. Nevertheless, this pattern of DNA methylation is erased and re-established in germline. As results, in mature sperm H19 ICR shows biallelic methylation instead of paternal specific methylation in somatic cells. Although the data were mainly from experiments on mice the same mechanisms are believed existing in human germline. We designed an experiment to probe the sperm DNA by methylation sensitive restriction enzyme based nested qPCR (MSRE-nested-qPCR). The genomic DNA digested/undigested by HhaI was amplified by outer primers encompassing four HhaI sites on H19 ICR. These PCR products were used as templates for second round real-time PCR to quantify the DNA methylation level. The results showed that DNA methylation level at H19 ICR were 55.27 ± 8.36% in 32 blood samples and 101.94 ± 11.66% in 31 semen samples. Based on our data sperm DNA could be identified if H19 ICR methylation level is over 78.62%.

  12. Validation of Zebrafish (Danio rerio) Reference Genes for Quantitative Real-time RT-PCR Normalization

    Institute of Scientific and Technical Information of China (English)

    Rongying TANG; Andrew DODD; Daniel LAI; Warren C.MCNABB; Donald R.LOVE

    2007-01-01

    The normalization of quantitative real time RT-PCR (qRT-PCR) is important to obtain accurate gene expression data. The most common method for qRT-PCR normalization is to use reference, or housekeeping genes. However, there is emerging evidence that even reference genes can be regulated under different conditions, qRT-PCR has only recently been used in terms of zebrafish gene expression studies and there is no validated set of reference genes. This study characterizes the expression of nine possible reference genes during zebrafish embryonic development and in a zebrafish tissue panel. All nine reference genes exhibited variable expression. The β-actin, EF1α and Rpl13α genes comprise a validated reference gene panel for zebrafish developmental time course studies, and the EF1α, Rpl13α and 18S rRNA genes are more suitable as a reference gene panel for zebrafish tissue analysis. Importantly, the zebrafish GAPDH gene appears unsuitable as reference gene for both types of studies.

  13. Detection by real time PCR of walnut allergen coding sequences in processed foods.

    Science.gov (United States)

    Linacero, Rosario; Ballesteros, Isabel; Sanchiz, Africa; Prieto, Nuria; Iniesto, Elisa; Martinez, Yolanda; Pedrosa, Mercedes M; Muzquiz, Mercedes; Cabanillas, Beatriz; Rovira, Mercè; Burbano, Carmen; Cuadrado, Carmen

    2016-07-01

    A quantitative real-time PCR (RT-PCR) method, employing novel primer sets designed on Jug r 1, Jug r 3, and Jug r 4 allergen-coding sequences, was set up and validated. Its specificity, sensitivity, and applicability were evaluated. The DNA extraction method based on CTAB-phenol-chloroform was best for walnut. RT-PCR allowed a specific and accurate amplification of allergen sequence, and the limit of detection was 2.5pg of walnut DNA. The method sensitivity and robustness were confirmed with spiked samples, and Jug r 3 primers detected up to 100mg/kg of raw walnut (LOD 0.01%, LOQ 0.05%). Thermal treatment combined with pressure (autoclaving) reduced yield and amplification (integrity and quality) of walnut DNA. High hydrostatic pressure (HHP) did not produce any effect on the walnut DNA amplification. This RT-PCR method showed greater sensitivity and reliability in the detection of walnut traces in commercial foodstuffs compared with ELISA assays.

  14. A real-time, quantitative PCR protocol for assessing the relative parasitemia of Leucocytozoon in waterfowl

    Science.gov (United States)

    Smith, Matthew M.; Schmutz, Joel A.; Apelgren, Chloe; Ramey, Andy M.

    2015-01-01

    Microscopic examination of blood smears can be effective at diagnosing and quantifying hematozoa infections. However, this method requires highly trained observers, is time consuming, and may be inaccurate for detection of infections at low levels of parasitemia. To develop a molecular methodology for identifying and quantifying Leucocytozoon parasite infection in wild waterfowl (Anseriformes), we designed a real-time, quantitative PCR protocol to amplify Leucocytozoon mitochondrial DNA using TaqMan fluorogenic probes and validated our methodology using blood samples collected from waterfowl in interior Alaska during late summer and autumn (n = 105). By comparing our qPCR results to those derived from a widely used nested PCR protocol, we determined that our assay showed high levels of sensitivity (91%) and specificity (100%) in detecting Leucocytozoon DNA from host blood samples. Additionally, results of a linear regression revealed significant correlation between the raw measure of parasitemia produced by our qPCR assay (Ct values) and numbers of parasites observed on blood smears (R2 = 0.694, P = 0.003), indicating that our assay can reliably determine the relative parasitemia levels among samples. This methodology provides a powerful new tool for studies assessing effects of haemosporidian infection in wild avian species.

  15. EMA-real-time PCR as a reliable method for detection of viable Salmonella in chicken and eggs.

    Science.gov (United States)

    Wang, Luxin; Mustapha, Azlin

    2010-04-01

    Culture-based Salmonella detection takes at least 4 d to complete. The use of TaqMan probes allows the real-time PCR technique to be a rapid and sensitive way to detect foodborne pathogens. However, unlike RNA-based PCR, DNA-based PCR techniques cannot differentiate between DNA from live and dead cells. Ethidium bromide monoazide (EMA) is a dye that can bind to DNA of dead cells and prevent its amplification by PCR. An EMA staining step prior to PCR allows for the effective inhibition of false positive results from DNA contamination by dead cells. The aim of this study was to design an accurate detection method that can detect only viable Salmonella cells from poultry products. The sensitivity of EMA staining coupled with real-time PCR was compared to that of an RNA-based reverse transcription (RT)-real-time PCR. To prevent false negative results, an internal amplification control was added to the same reaction mixture as the target Salmonella sequences. With an optimized EMA staining step, the detection range of a subsequent real-time PCR was determined to be 10(3) to 10(9) CFU/mL for pure cultures and 10(5) to 10(9) CFU/mL for food samples, which was a wider detection range than for RT-real-time PCR. After a 12-h enrichment step, EMA staining combined with real-time PCR could detect as low as 10 CFU/mL Salmonella from chicken rinses and egg broth. The use of EMA with a DNA-based real-time PCR can successfully prevent false positive results and represents a simple, yet accurate detection tool for enhancing the safety of food.

  16. Development of real time PCR for detection and quantitation of Dengue Viruses

    Directory of Open Access Journals (Sweden)

    Singh A

    2009-01-01

    Full Text Available Abstract Background Dengue virus (DENV, a mosquito borne flavivirus is an important pathogen causing more than 50 million infections every year around the world. Dengue diagnosis depends on serology, which is not useful in the early phase of the disease and virus isolation, which is laborious and time consuming. There is need for a rapid, sensitive and high throughput method for detection of DENV in the early stages of the disease. Several real-time PCR assays have been described for dengue viruses, but there is scope for improvement. The new generation TaqMan Minor Groove Binding (MGB probe approach was used to develop an improved real time RT-PCR (qRT-PCR for DENV in this study. Results The 3'UTR of thirteen Indian strains of DENV was sequenced and aligned with 41 representative sequences from GenBank. A region conserved in all four serotypes was used to target primers and probes for the qRT-PCR. A single MGB probe and a single primer pair for all the four serotypes of DENV were designed. The sensitivity of the two step qRT-PCR assay was10 copies of RNA molecules per reaction. The specificity and sensitivity of the assay was 100% when tested with a panel of 39 known positive and negative samples. Viral RNA could be detected and quantitated in infected mouse brain, cell cultures, mosquitoes and clinical samples. Viral RNA could be detected in patients even after seroconversion till 10 days post onset of infection. There was no signal with Japanese Encephalitis (JE, West Nile (WN, Chikungunya (CHK viruses or with Leptospira, Plasmodium vivax, Plasmodium falciparum and Rickettsia positive clinical samples. Conclusion We have developed a highly sensitive and specific qRT-PCR for detection and quantitation of dengue viruses. The assay will be a useful tool for differential diagnosis of dengue fever in a situation where a number of other clinically indistinguishable infectious diseases like malaria, Chikungunya, rickettsia and leptospira occur. The

  17. Real time TaqMan RT-PCR assay for the detection of Cucumber green mottle mosaic virus.

    Science.gov (United States)

    Hongyun, Chen; Wenjun, Zhao; Qinsheng, Gu; Qing, Chen; Shiming, Lin; Shuifang, Zhu

    2008-05-01

    A real time reverse-transcription polymerase chain reaction (RT-PCR) was developed for efficient detection of Cucumber green mottle mosaic virus (CGMMV). The method was designed to use a duo-primer system with a TaqMan probe targeting the conserved sequence in 3' noncoding region (NCR) of CGMMV to detect isolates of this virus collected in China. The sensitivity of the real time RT-PCR assay was 0.13 pg of total RNA or 50 molecules of RNA transcripts. This level of sensitivity indicated that the one step real time RT-PCR developed in the present study could be used for routine testing assays. The real time RT-PCR method could assist in the implementation of quarantine measures for prevention and control of the disease caused by CGMMV.

  18. A LightCycler real-time PCR hybridization probe assay for detecting food-borne thermophilic Campylobacter

    DEFF Research Database (Denmark)

    Perelle, S.; Josefsen, Mathilde Hartmann; Hoorfar, Jeffrey

    2004-01-01

    Cycler real-time PCR assay (LC-PCR), which used fluorescent hybridization probes was developed. The test incorporated an internal amplification control co-amplified with the 16S rRNA gene of Campylobacter to monitor potential PCR inhibitors and ensure successful amplifications. The specificity study involving...

  19. The use sof real-time quantitative PCR for the analysis of cytokine mRNA levels

    NARCIS (Netherlands)

    Forlenza, M.; Kaiser, T.; Savelkoul, H.F.J.; Wiegertjes, G.F.

    2012-01-01

    Over the last decade, real-time-quantitative PCR (RT-qPCR) analysis has become the method of choice not only for quantitative and accurate measurement of mRNA expression levels, but also for sensitive detection of rare or mutated DNA species in diagnostic research. RT-qPCR is based on the standard p

  20. Real time RT-PCR assay for detection of different serotypes of FMDV in Egypt

    Directory of Open Access Journals (Sweden)

    Laila El-Shehawy

    Full Text Available Aim: The present study indicated that rRT-PCR could be provided for the detection of FMDV in infected, contact and carrier cattle and also provide a rapid sensitive tool aiming to aid in rapid disease detection and control. Foot and Mouth disease virus serotypes O and A still existing in Egypt. In January 2012, sever outbreaks struck the animal population in most Egyptian 1 governorates. The causative virus was identified as FMDV SAT2. Material and Methods: Five samples of tongue epithelium (ET and five oesophageal-pharyngeal (OP fluid samples were collected from FMD suspected cattle in infected farm at El-Fayoum and 20 OP samples from in-contact cattle at the same farm in addition to 30 OP samples from apparently healthy cattle at three different localities in El-Fayoum governorate (12 from Fayoum; 9 from Sinoras and 9 from Edsa in order to detect carrier cattle. All of these samples were collected during November and December 2011 and January 2012. Results: All the ET and OP samples were inoculated on BHK cell culture and baby mice. The obtained results were identified using complement fixation test in addition to real-time reverse transcriptase polymerase chain reaction (rRT-PCR. In the infected farm at El-Fayoum FMDV type SAT2 was detected in cattle which are considered as the first introduction of this type while FMDV type O and SAT2 were detected in the in-contact cattle in the same farm. The sensitivity of rRT-PCR was cleared in the in-contact cattle as 13 out of 20 OP samples were positive to FMDV by rRT-PCR while 11 out of 20 OP samples were positive to FMDV by CFT. The OP samples collected from apparently healthy cattle from Fayoum, Sinoras and Edsa localities in Fayoum governorate demonstrate the circulation of the FMDV type A, O and the recent SAT2 in carrier cattle which threaten cattle population in Fayoum governorate. Also the sensitivity of real time RT-PCR over the CFT in detection of FMDV carrier cattle was clearly noticed in

  1. Multiplex real time PCR panels to identify fourteen colonization factors of enterotoxigenic Escherichia coli (ETEC).

    Science.gov (United States)

    Liu, Jie; Silapong, Sasikorn; Jeanwattanalert, Pimmada; Lertsehtakarn, Paphavee; Bodhidatta, Ladaporn; Swierczewski, Brett; Mason, Carl; McVeigh, Annette L; Savarino, Stephen J; Nshama, Rosemary; Mduma, Esto; Maro, Athanasia; Zhang, Jixian; Gratz, Jean; Houpt, Eric R

    2017-01-01

    Enterotoxigenic Escherichia coli (ETEC) is a leading cause of childhood diarrhea in low income countries and in travelers to those areas. Inactivated enterotoxins and colonization factors (CFs) are leading vaccine candidates, therefore it is important to determine the prevailing CF types in different geographic locations and populations. Here we developed real time PCR (qPCR) assays for 14 colonization factors, including the common vaccine targets. These assays, along with three enterotoxin targets (STh, STp, and LT) were formulated into three 5-plex qPCR panels, and validated on 120 ETEC isolates and 74 E. coli colony pools. The overall sensitivity and specificity was 99% (199/202) and 99% (2497/2514), respectively, compared to the CF results obtained with conventional PCR. Amplicon sequencing of discrepant samples revealed that the qPCR was 100% accurate. qPCR panels were also performed on nucleic acid extracted from stool and compared to the results of the ETEC isolates or E. coli colony pools cultured from them. 95% (105/110) of the CF detections in the cultures were confirmed in the stool. Additionally, direct testing of stool yielded 30 more CF detections. Among 74 randomly selected E. coli colony pools with paired stool, at least one CF was detected in 63% (32/51) of the colony pools while at least one CF was detected in 78% (47/60) of the stool samples (P = NS). We conclude that these ETEC CF assays can be used on both cultures and stool samples to facilitate better understanding of CF distribution for ETEC epidemiology and vaccine development.

  2. Utility of a fecal real-time PCR protocol for detection of Mycobacterium bovis infection in African buffalo (Syncerus caffer).

    Science.gov (United States)

    Roug, Annette; Geoghegan, Claire; Wellington, Elizabeth; Miller, Woutrina A; Travis, Emma; Porter, David; Cooper, David; Clifford, Deana L; Mazet, Jonna A K; Parsons, Sven

    2014-01-01

    A real-time PCR protocol for detecting Mycobacterium bovis in feces was evaluated in bovine tuberculosis-infected African buffalo (Syncerus caffer). Fecal samples spiked with 1.42 × 10(3) cells of M. bovis culture/g and Bacille Calmette-Guérin standards with 1.58 × 10(1) genome copies/well were positive by real-time PCR but all field samples were negative.

  3. Pre-Clinical Testing of Real-Time PCR Assays for Diarrheal Disease Agents of Genera Escherichia and Shigella

    Science.gov (United States)

    2014-05-16

    FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA May 16, 2014 Reporting Period: October 1, 2010 to September 30, 2013...10-2010 - 30-09-2013 PRE-CLINICAL TESTING OF REAL-TIME PCR ASSAYS FOR DIARRHEAL DISEASE AGENTS OF GENERA ESCHERICHIA AND SHIGELLA ...Texas (MOA 2007 - 2013. Agreement No.: DODI 4000.19; AFI 25-201). Pre-clinical test results qualify ETEC and Shigella real-time PCR assays as lead

  4. Rapid detection of blaKPC carbapenemase genes by real-time PCR.

    Science.gov (United States)

    Hindiyeh, Musa; Smollen, Gill; Grossman, Zehava; Ram, Daniela; Davidson, Yehudit; Mileguir, Fernando; Vax, Marina; Ben David, Debbie; Tal, Ilana; Rahav, Galia; Shamiss, Ari; Mendelson, Ella; Keller, Nathan

    2008-09-01

    Carbapenem resistance among Enterobacteriaceae is an emerging problem worldwide. Klebsiella pneumoniae carbapenemase (bla(KPC)) enzymes are among the most common beta-lactamases described. In this study, we report the development and validation of a real-time PCR (q-PCR) assay for the detection of bla(KPC) genes using TaqMan chemistry. The q-PCR amplification of bla(KPC) DNA was linear over 7 log dilutions (r(2) = 0.999; slope, 3.54), and the amplification efficiency was 91.6%. The q-PCR detection limit was 1 CFU, and there was no cross-reaction with DNA extracted from several multidrug-resistant bacteria. Perianal/rectal swabs (n = 187) collected in duplicate from 128 patients admitted to Sheba Medical Center surgical intensive care units were evaluated for the presence of carbapenem-resistant bacteria by culturing on MacConkey agar-plus-carbapenem disks and for bla(KPC) genes by q-PCR. Carbapenem-resistant organisms, all K. pneumoniae, were isolated from 47 (25.1%) of the 187 samples collected, while bla(KPC) genes were detected in 54 (28.9%) of the patient samples extracted by the NucliSENS easyMAG system. Of these, seven samples were positive for bla(KPC) genes by q-PCR but negative for carbapenem resistance by culture, while all samples in which no carbapenem-resistant bacteria were detected by culture also tested negative by q-PCR. Thus, the sensitivity and specificity of the q-PCR assay after extraction by the NucliSENS easyMAG system were 100% and 95%, respectively. Similar values were obtained after DNA extraction by the Roche MagNA Pure LC instrument: 97.9% sensitivity and 96.4% specificity. Overall, the bla(KPC) q-PCR assay appears to be highly sensitive and specific. The utilization of q-PCR will shorten the time to bla(KPC) detection from 24 h to 4 h and will help in rapidly isolating colonized or infected patients and assigning them to cohorts.

  5. 子代T4的PCR和real time PCR测定%Quantification of progeny T4 by PCR and real-time PCR

    Institute of Scientific and Technical Information of China (English)

    刘邻渭; 杨公明

    2007-01-01

    目的:为建立通过测定转换样品T4而检验样品大肠杆菌的新方法,探讨快速测定转换样品中T4的PCR技术.方法:以T4DNA纯化样品水稀释液和转换样品沸水浴处理产物分别为模板样液,经过两对引物PCR及real time PCR的试用和比较,优选定量检测转换样品中T4的适宜方法和条件.结果:源自T4 ligase的一对引物具有较高的灵敏度和特异性;针对纯化T4DNA配制的模板样液,优化的PCR和real time PCR至少可分别精确检出39.25和3.925 pg/ml的T4DNA;针对沸水浴处理转换样品制备的模板样液,PCR和real time PCR可清楚区别不同浓度的转换样品,PCR的检出极限为500 PFU/ml T4的转换样品,real time PCR的检测极限为35 PFU/ml T4的转换样品.结论:采用PCR和real time PCR可快速定量测定转换样品中的T4含量,real time PCR比PCR的灵敏度高约一个数量级.

  6. Comparative Study on Real-time PCR and RT-PCR Testing Methods for Detecting human Metapneumo Virus%Real-time PCR与RT-PCR检测儿童人偏肺病毒

    Institute of Scientific and Technical Information of China (English)

    郭鑫; 崔玉霞; 诸葛姝芮; 刘兴梅

    2015-01-01

    目的:比较荧光定量PCR( real-time PCR)与普通反转录酶-聚合酶链锁反应( RT-PCR)对人偏肺病毒( hMPV)的检测价值。方法:Real-time PCR和RT-PCR同时对500例急性下呼吸道感染( ALRTI)患儿鼻咽部分泌物进行hMPV检测,分析两种方法的特异性和灵敏性。结果:Real-time PCR和RT-PCR的检出率分别为16%及9.8%,RT-PCR与Real-time PCR比较,灵敏度为31.3%(25/80),特异度为94.3%(396/420)。结论:Real-time PCR检测hMPV敏感性高于RT-PCR,是临床检测儿童鼻咽部分泌物hMPV感染的有效的方法。%Objective:To investigate the effect of real-time quantitative PCR and RT-PCR in detec-tion of human metapneumo virus. Methods:Real-time PCR and RT-PCR are adopted to test hMPV on throat exudate of 500 acute lower respiratory tract infection( ALRTI)child patients,analyzing the spe-cificity and sensitivity of both assays. Results:Comparing Real-time PCR and RT-PCR,the detection rates were 16 % to 9. 8%. Comparing Real-time PCR and RT-PCR,the sensitivity and specificity were 31. 3 %(25/80)and 94. 3%(396/420)respectively. Conclusion:The sensitivity of Real-time PCR is significantly higher than RT-PCR in detection of hMPV,which provid an effective method for detection of hMPV.

  7. Characterization and analysis of real-time capillary convective PCR toward commercialization.

    Science.gov (United States)

    Qiu, Xianbo; Zhang, Shiyin; Mei, Lanju; Wu, Di; Guo, Qi; Li, Ke; Ge, Shengxiang; Ye, Xiangzhong; Xia, Ningshao; Mauk, Michael G

    2017-03-01

    Almost all the reported capillary convective polymerase chain reaction (CCPCR) systems to date are still limited to research use stemming from unresolved issues related to repeatability, reliability, convenience, and sensitivity. To move CCPCR technology forward toward commercialization, a couple of critical strategies and innovations are discussed here. First, single- and dual-end heating strategies are analyzed and compared between each other. Especially, different solutions for dual-end heating are proposed and discussed, and the heat transfer and fluid flow inside the capillary tube with an optimized dual-end heating strategy are analyzed and modeled. Second, real-time CCPCR is implemented with light-emitting diode and photodiode, and the real-time fluorescence detection method is compared with the post-amplification end-point detection method based on a dipstick assay. Thirdly, to reduce the system complexity, e.g., to simplify parameter tuning of the feedback control, an internal-model-control-based proportional-integral-derivative controller is adopted for accurate temperature control. Fourth, as a proof of concept, CCPCR with pre-loaded dry storage of reagent inside the capillary PCR tube is evaluated to better accommodate to point-of-care diagnosis. The critical performances of improved CCPCR, especially with sensitivity, repeatability, and reliability, have been thoroughly analyzed with different experiments using influenza A (H1N1) virus as the detection sample.

  8. A New Lab Developed Real Time PCR Assay for Direct Detection of C. Difficle from Stool Sample without DNA Extraction.

    Science.gov (United States)

    Li, Brandon

    2016-09-01

    Clostridium difficile is a major cause of nosocomial antibiotic-associated infectious diarrhea and pseudomembranous colitis. Detection of C. difficile by anaerobic bacterial culture and/or cytotoxicity assays has been largely replaced by rapid enzyme immunoassays (EIA). However, due to the lack of sensitivity of stool EIA, we developed a multiplex real-time PCR assay targeting the C. difficile toxin genes tcdB. stool samples from hospitalized pediatric patients suspected of having C. difficile-associated disease were prospectively collected. Three testing modalities were evaluated, including enriched culture, cepheid Xpert and real-time Pcr (tcdB) on stool samples performed with tcdB gene-specific primers and hydrolysis probes. A total of 150 de-identified clinical specimen were analyzed. The sensitivities of stool real-time Pcr were 95% against cepheid Xpert C. difficile and 93% against enriched culture respectively, with a specificity of 97% and 94%. The lower limit of detection of the stool real-time PCR was 0.5 cFU/ml of per reaction for tcdB. Direct detection of C. difficile toxin genes in stool samples by real-time Pcr showed performance comparable to enriched culture. Real-time PCR of DNA from stool samples is a rapid and cost-effective diagnostic modality for patients that should facilitate appropriate patient management.

  9. A New Lab Developed Real Time PCR Assay for Direct Detection of C. Difficle from Stool Sample without DNA Extraction

    Science.gov (United States)

    Li, Brandon

    2016-01-01

    Clostridium difficile is a major cause of nosocomial antibiotic-associated infectious diarrhea and pseudomembranous colitis. Detection of C. difficile by anaerobic bacterial culture and/or cytotoxicity assays has been largely replaced by rapid enzyme immunoassays (EIA). However, due to the lack of sensitivity of stool EIA, we developed a multiplex real-time PCR assay targeting the C. difficile toxin genes tcdB. stool samples from hospitalized pediatric patients suspected of having C. difficile-associated disease were prospectively collected. Three testing modalities were evaluated, including enriched culture, cepheid Xpert and real-time Pcr (tcdB) on stool samples performed with tcdB gene-specific primers and hydrolysis probes. A total of 150 de-identified clinical specimen were analyzed. The sensitivities of stool real-time Pcr were 95% against cepheid Xpert C. difficile and 93% against enriched culture respectively, with a specificity of 97% and 94%. The lower limit of detection of the stool real-time PCR was 0.5 cFU/ml of per reaction for tcdB. Direct detection of C. difficile toxin genes in stool samples by real-time Pcr showed performance comparable to enriched culture. Real-time PCR of DNA from stool samples is a rapid and cost-effective diagnostic modality for patients that should facilitate appropriate patient management. PMID:27829823

  10. Detection of selected intestinal helminths and protozoa at Hospital Universiti Sains Malaysia using multiplex real-time PCR.

    Science.gov (United States)

    Basuni, M; Mohamed, Z; Ahmad, M; Zakaria, N Z; Noordin, R

    2012-09-01

    Intestinal parasites are the causative agents of a number of important human infections in developing countries. The objective of this study was to determine the prevalence of selected helminths and protozoan infections among patients admitted with gastrointestinal disorders at Hospital Universiti Sains Malaysia, Kelantan, Malaysia using multiplex real-time PCR. In addition microscopic examination was also performed following direct smear, zinc sulphate concentration and Kato-Katz thick smear techniques; and the presence of protozoan parasites was confirmed using trichrome and acid-fast stains. Of the 225 faecal samples analysed, 26.2% were positive for intestinal parasites by the multiplex real-time PCR, while 5.3% were positive by microscopy. As compared to microscopy, the multiplex real-time PCR detected 5.8 and 4.5 times more positives for the selected helminth and protozoan infections respectively. Among the selected helminths detected in this study, hookworm was the most prevalent by real-time PCR, while Ascaris lumbricoides was detected the most by microscopy. Meanwhile, among the selected protozoa detected in this study, Entamoeba histolytica was the most prevalent by real-time PCR, however microscopy detected equal number of cases with E. histolytica and Giardia lamblia. This study showed that real-time PCR can be used to obtain a more accurate prevalence data on intestinal helminths and protozoa.

  11. Real-time PCR quantification of human complement C4A and C4B genes

    Directory of Open Access Journals (Sweden)

    Fust George

    2006-01-01

    Full Text Available Abstract Background The fourth component of human complement (C4, an essential factor of the innate immunity, is represented as two isoforms (C4A and C4B in the genome. Although these genes differ only in 5 nucleotides, the encoded C4A and C4B proteins are functionally different. Based on phenotypic determination, unbalanced production of C4A and C4B is associated with several diseases, such as systemic lupus erythematosus, type 1 diabetes, several autoimmune diseases, moreover with higher morbidity and mortality of myocardial infarction and increased susceptibility for bacterial infections. Despite of this major clinical relevance, only low throughput, time and labor intensive methods have been used so far for the quantification of C4A and C4B genes. Results A novel quantitative real-time PCR (qPCR technique was developed for rapid and accurate quantification of the C4A and C4B genes applying a duplex, TaqMan based methodology. The reliable, single-step analysis provides the determination of the copy number of the C4A and C4B genes applying a wide range of DNA template concentration (0.3–300 ng genomic DNA. The developed qPCR was applied to determine C4A and C4B gene dosages in a healthy Hungarian population (N = 118. The obtained data were compared to the results of an earlier study of the same population. Moreover a set of 33 samples were analyzed by two independent methods. No significant difference was observed between the gene dosages determined by the employed techniques demonstrating the reliability of the novel qPCR methodology. A Microsoft Excel worksheet and a DOS executable are also provided for simple and automated evaluation of the measured data. Conclusion This report describes a novel real-time PCR method for single-step quantification of C4A and C4B genes. The developed technique could facilitate studies investigating disease association of different C4 isotypes.

  12. Evaluation of a new single-tube multiprobe real-time PCR for diagnosis of Entamoeba histolytica and Entamoeba dispar.

    Science.gov (United States)

    Liang, Shih-Yu; Hsia, Kan-Tai; Chan, Yun-Hsien; Fan, Chia-Kwung; Jiang, Donald Dah-Shyong; Landt, Olfert; Ji, Dar-Der

    2010-08-01

    A single-tube multiprobe real-time PCR assay for simultaneous detection of Entamoeba histolytica and Entamoeba dispar was developed. One primer pair with 2 species-specific probes was designed based on new SSU RNA regions of the ribosomal DNA-containing episome. The sensitivity is 1 parasite per milliliter of feces and thus superior to the conventional nested PCR and comparable to other published real-time PCR protocols. The applicability for clinical diagnosis was validated with 218 stool specimens from patients. A total of 51 E. histolytica and 39 E. dispar positive samples was detected by the multiprobe real-time PCR compared to 39 and 22 by routine nested PCR diagnosis. The detection rate of Entamoeba species for the multiprobe real-time PCR assays was significantly higher than the nested PCR (40.8% vs. 28.0%, P Entamoeba moshkovskii, Giardia lamblia , Cryptosporidium sp., Escherichia coli , or other nonpathogenic enteric parasites. The multiprobe real-time PCR assay is simple and rapid and has high specificity and sensitivity. The assay could streamline the laboratory diagnosis procedure and facilitate epidemiological investigation.

  13. Quantitative analysis of the dystrophin gene by real-time PCR

    Directory of Open Access Journals (Sweden)

    Maksimovic Nela

    2012-01-01

    Full Text Available Duchenne and Becker muscular dystrophy (DMD/BMD are severe X-linked neuromuscular disorders caused by mutations in the dystrophin gene. Our aim was to optimize a quantitative real-time PCR method based on SYBR® Green I chemistry for routine diagnostics of DMD/BMD deletion carriers. Twenty female relatives of DMD/BMD patients with previously detected partial gene deletions were studied. The relative quantity of the target exons was calculated by a comparative threshold cycle method (ΔΔCt. The carrier status of all subjects was successfully determined. The gene dosage ratio for non-carriers was 1.07±0.20, and for carriers 0.56±0.11. This assay proved to be simple, rapid, reliable and cost-effective.

  14. A battery-powered notebook thermal cycler for rapid multiplex real-time PCR analysis.

    Science.gov (United States)

    Belgrader, P; Young, S; Yuan, B; Primeau, M; Christel, L A; Pourahmadi, F; Northrup, M A

    2001-01-15

    A compact, real-time PCR instrument was developed for rapid, multiplex analysis of nucleic acids in an inexpensive, portable format. The instrument consists of a notebook computer, two reaction modules with integrated optics for four-color fluorescence detection, batteries, and a battery-charging system. The instrument weighs 3.3 kg, measures 26 x 22 x 7.5 cm, and can run continuously on the internal batteries for 4 h. Independent control of the modules allows differing temperature profiles and detection schemes to be run simultaneously. Results are presented that demonstrate rapid (1) detection and identification of Bacillus subtilis and Bacillus thuringensis spores and (2) characterization of a single nucleotide polymorphism for the hereditary hemochromatosis gene.

  15. Development of a real-time PCR method for the identification of Atlantic mackerel (Scomber scombrus).

    Science.gov (United States)

    Velasco, Amaya; Sánchez, Ana; Martínez, Icíar; Santaclara, Francisco J; Pérez-Martín, Ricardo I; Sotelo, Carmen G

    2013-12-01

    A Real Time-PCR method based on TaqMan technology for the identification of Scomber scombrus has been developed. A system of specific primers and a Minor Groove Binding (MGB) TaqMan probe based on sequences of the mitochondrial cytochrome b region was designed. The method was successfully tested in 81 specimens of S. scombrus and related species and validated in 26 different commercial samples. An average Threshold Cycle (Ct) value of 15.3 was obtained with S. scombrus DNA. With the other species tested fluorescence signal was not detected or Ct was significantly higher (P<0.001). The efficiency of the assay was estimated to be 92.41%, with 100% specificity, and no cross reactivity was detected with any other species. These results reveal that the developed method is a rapid and efficient tool to unequivocally identify S. scombrus and may aid in the prevention of fraud or mislabelling in mackerel products.

  16. Real-time immuno-PCR: an approach for detection of trace amounts of transgenic proteins.

    Science.gov (United States)

    Kumar, Rajesh; Sinha, Rajeshwar P

    2014-01-01

    The research on manipulation of crop genomes for transgenic development is continuously increasing due to several benefits. The major concerns linked to the effect of transgenic crops are human health and environment sustainability. To monitor transgenic samples in the food chain, several highly sensitive and specific DNA-based and protein-based detection methods are being used. However, real- time immunio-PCR (RT-IPCR) assay would be able to provide a sensitive detection of trace amounts of transgenic proteins or allergens in the samples and help in monitoring these materials. In the present study, we developed a novel RT-IPCR method to monitor CrylAc transgenic protein in samples with an LOD of 100 pg/mL. The assay may also be useful in the evaluation of functional stability of transgenes inserted in the plant genome.

  17. Seasonal variation in transcript abundance in cork tissue analyzed by real time RT-PCR.

    Science.gov (United States)

    Soler, Marçal; Serra, Olga; Molinas, Marisa; García-Berthou, Emili; Caritat, Antònia; Figueras, Mercè

    2008-05-01

    The molecular processes underlying cork biosynthesis and differentiation are mostly unknown. Recently, a list of candidate genes for cork biosynthesis and regulation was made available opening new possibilities for molecular studies in cork oak (Quercus suber L.). Based on this list, we analyzed the seasonal variation in mRNA abundance in cork tissue of selected genes by real time reverse-transcriptase polymerase chain reaction (RT-PCR). Relative transcript abundance was evaluated by principal component analysis and genes were clustered in several functional subgroups. Structural genes of suberin pathways such as CYP86A1, GPAT and HCBT, and regulatory genes of the NAM and WRKY families showed highest transcript accumulation in June, a crucial month for cork development. Other cork structural genes, such as FAT and F5H, were significantly correlated with temperature and relative humidity. The stress genes HSP17.4 and ANN were strongly positively correlated to temperature, in accord with their protective role.

  18. Integrated sorting, concentration and real time PCR based detection system for sensitive detection of microorganisms

    Science.gov (United States)

    Nayak, Monalisha; Singh, Deepak; Singh, Himanshu; Kant, Rishi; Gupta, Ankur; Pandey, Shashank Shekhar; Mandal, Swarnasri; Ramanathan, Gurunath; Bhattacharya, Shantanu

    2013-11-01

    The extremely low limit of detection (LOD) posed by global food and water safety standards necessitates the need to perform a rapid process of integrated detection with high specificity, sensitivity and repeatability. The work reported in this article shows a microchip platform which carries out an ensemble of protocols which are otherwise carried in a molecular biology laboratory to achieve the global safety standards. The various steps in the microchip include pre-concentration of specific microorganisms from samples and a highly specific real time molecular identification utilizing a q-PCR process. The microchip process utilizes a high sensitivity antibody based recognition and an electric field mediated capture enabling an overall low LOD. The whole process of counting, sorting and molecular identification is performed in less than 4 hours for highly dilute samples.

  19. Real-Time PCR Assay for the Identification of the Brown Marmorated Stink Bug (Halyomorpha halys

    Directory of Open Access Journals (Sweden)

    Manpreet K Dhami

    2016-02-01

    Full Text Available The brown marmorated stink bug, Halyomorpha halys (Hemiptera: Pentatomidae, is a gregarious crop pest that has rapidly spread across the world in the last two decades. It is an excellent hitchhiker species, especially as an over-wintering adult. During this period it is often associated with non-biological commodities such as shipping containers and machinery that travel long distances. Inadequate identification keys and similarity to common species has assisted its spread across Europe, while accurate identification from immature stages or eggs is not possible. We developed a real-time TaqMan PCR assay for the accurate and sensitive detection of the brown marmorated stink bug from all life stages. The assay performance against required diagnostic criterion and within a quarantine framework are described.

  20. Diagnosis of Lobesia botrana (Lepidoptera: Tortricidae) Using Real-Time PCR.

    Science.gov (United States)

    Ledezma, L A; Barr, N B; Epstein, M E; Gilligan, T M

    2016-08-01

    A real-time PCR assay is reported for identification of Lobesia botrana (Denis and Schiffermüller) collected in California. This assay multiplexes two independent TaqMan probe systems in a single reaction tube to reduce handling time and sample exposure to environmental contaminants. One probe system targets a segment of DNA located in the internal transcribed spacer region 2 (ITS2) that is present in the L. botrana genome but absent in native North American Tortricidae. The second probe system serves as a control for DNA quality by targeting a segment of the 18S rDNA gene that is conserved in L. botrana and all of the tested nontarget species. The assay successfully diagnosed 70 Lobesia botrana specimens and 95 nontarget specimens. No false-positive or false-negative results were observed supporting its application for identification of this pest in California.

  1. Monitoring Acidophilic Microbes with Real-Time Polymerase Chain Reaction (PCR) Assays

    Energy Technology Data Exchange (ETDEWEB)

    Frank F. Roberto

    2008-08-01

    Many techniques that are used to characterize and monitor microbial populations associated with sulfide mineral bioleaching require the cultivation of the organisms on solid or liquid media. Chemolithotrophic species, such as Acidithiobacillus ferrooxidans and Leptospirillum ferrooxidans, or thermophilic chemolithotrophs, such as Acidianus brierleyi and Sulfolobus solfataricus can grow quite slowly, requiring weeks to complete efforts to identify and quantify these microbes associated with bioleach samples. Real-time PCR (polymerase chain reaction) assays in which DNA targets are amplified in the presence of fluorescent oligonucleotide primers, allowing the monitoring and quantification of the amplification reactions as they progress, provide a means of rapidly detecting the presence of microbial species of interest, and their relative abundance in a sample. This presentation will describe the design and use of such assays to monitor acidophilic microbes in the environment and in bioleaching operations. These assays provide results within 2-3 hours, and can detect less than 100 individual microbial cells.

  2. Investigations on abundance and activity of microbial sponge symbionts using quantitative real - time PCR

    DEFF Research Database (Denmark)

    Kumala, Lars; Hentschel, Ute; Bayer, Kristina

    Marine sponges are hosts to dense and diverse microbial consortia that are likely to play a key role in the metabolic processes of the host sponge due to their enormous abundance. Common symbioses between nitrogen transforming microorganisms and sponges indicate complex nitrogen cycling within...... the host. Of particular interest is determining the community structure and function of microbial symbionts in order to gain deeper insight into host-symbiont interactions. We investigated the abundance and activity of microbial symbionts in two Mediterranean sponge species using quantitative real-time PCR....... An absolute quantification of functional genes and transcripts in archaeal and bacterial symbionts was conducted to determine their involvement in nitrification and denitrification, comparing the low microbial abundance (LMA) sponge Dysidea avara with the high microbial abundance (HMA) representative Aplysina...

  3. Real-Time PCR Detection of Dogwood Anthracnose Fungus in Historical Herbarium Specimens from Asia.

    Science.gov (United States)

    Miller, Stephen; Masuya, Hayato; Zhang, Jian; Walsh, Emily; Zhang, Ning

    2016-01-01

    Cornus species (dogwoods) are popular ornamental trees and important understory plants in natural forests of northern hemisphere. Dogwood anthracnose, one of the major diseases affecting the native North American Cornus species, such as C. florida, is caused by the fungal pathogen Discula destructiva. The origin of this fungus is not known, but it is hypothesized that it was imported to North America with its host plants from Asia. In this study, a TaqMan real-time PCR assay was used to detect D. destructiva in dried herbarium and fresh Cornus samples. Several herbarium specimens from Japan and China were detected positive for D. destructiva, some of which were collected before the first report of the dogwood anthracnose in North America. Our findings further support that D. destructiva was introduced to North America from Asia where the fungus likely does not cause severe disease.

  4. Evaluation of baker's yeast in honey using a real-time PCR assay.

    Science.gov (United States)

    Kast, Christina; Roetschi, Alexandra

    2017-04-01

    Occasionally, melissopalynological analysis reveals the presence of baker's yeast (Saccharomyces cerevisiae) in honey sediments. A field experiment reproducing a common spring bee feeding practice, using sugar paste containing baker's yeast, was performed to understand how S. cerevisiae are introduced into honey. Apart from classical microscopy, a real-time quantitative PCR (qPCR) system specific for S. cerevisiae was established for quantification of S. cerevisiae in honeys. Results showed that S. cerevisiae cells are stored in the honey of the brood combs and are also transferred into honey in the supers. The concentrations of S. cerevisiae were highest in honey of the brood frames immediately after the feeding and decreased over time to low concentrations at the end of the year. A high content of S. cerevisiae cells were also found in the honey from supers of the spring harvest. Observed S. cerevisiae cells were not able to multiply in a high-sugar environment, such as honey, and their viability decreased rapidly after addition to the honey. The screening of 200 Swiss honeys revealed the presence of S. cerevisiae in 4.5% of the samples, as determined by microscopy and qPCR. Finally, the method described here may indicate an unwanted sucrose addition to honey through bee-feeding.

  5. [Diagnosis of whooping cough by serology and real-time PCR].

    Science.gov (United States)

    Mikešová, Romana; Stiborová, Ivana; Richter, Josef; Rajnohová Dobiášová, Lucie; Král, Vlastimil

    2013-09-01

    The goal of this study is to summarize the results of the detection of Bordetella pertussis (BP) and Bordetella parapertussis (BPP) by a real-time polymerase chain reaction (RT-PCR) assay and serological methods. In 2008-2010, 73 patients of the Department of Clinical Immunology and Allergology of the Centre for Immunology and Microbiology, Public Health Institute in Ústí nad Labem were screened for pertussis. They were selected according to the WHO and ECDC criteria, i. e. they presented with a persistent cough lasting more than two weeks. Direct detection of BP and BPP DNA from nasopharyngeal wash specimens was performed using a RT PCR assay. The serological responses were evaluated by a direct agglutination test for the detection of total antibodies and by enzyme-linked immunosobent assay (ELISA) for the detection of IgG, IgA, and IgM antibodies against pertussis toxin. Forty-two patients were positive for BP and/or BPP, 19 of them by RT-PCR (group A) and 23 by serology (group B). Ten group A patients (52.6%) were also positive by serology. Our results show that pertussis needs to be a consideration in persistent cough. We believe that increased awareness of the medical community, along with improved laboratory tests will result in increased detection of pertussis that is still considered by many physicians as a childhood infection.

  6. Detection of Nicotiana DNA in Tobacco Products Using a Novel Multiplex Real-Time PCR Assay.

    Science.gov (United States)

    Korchinski, Katie L; Land, Adrian D; Craft, David L; Brzezinski, Jennifer L

    2016-07-01

    Establishing that a product contains tobacco is a requirement for the U.S. Food and Drug Administration's regulation and/or prosecution of tobacco products. Therefore, a multiplex real-time PCR method was designed to determine if Nicotiana (tobacco) DNA is present in tobacco products. The PCR method simultaneously amplifies a 73 bp fragment of the cytochrome P450 monoxygenase CYP82E4 gene and 66 bp fragment in the nia-1 gene for nitrate reductase, which are detected using dual-labeled TaqMan probes. The assay is capable of detecting approximately 7.8 pg purified tobacco DNA, with a similar sensitivity for either gene target while incorporating an internal positive control (IPC). DNA was extracted from prepared tobacco products-including chewing tobacco, pipe tobacco, and snuff-or from the cut fill (no wrapper) of cigarettes and cigars. Of the 13 products analyzed, 12 were positive for both tobacco-specific markers and the IPC. DNA was also extracted from the fill of five varieties of herbal cigarettes, which were negative for both tobacco-specific gene targets and positive for the IPC. Our method expands on current assays by introducing a multiplex reaction, targeting two sequences in two different genes of interest, incorporating an IPC into the reaction, and lowering the LOD and LOQ while increasing the efficiency of the PCR.

  7. FungiQuant: A broad-coverage fungal quantitative real-time PCR assay

    Directory of Open Access Journals (Sweden)

    Liu Cindy M

    2012-11-01

    Full Text Available Abstract Background Fungal load quantification is a critical component of fungal community analyses. Limitation of current approaches for quantifying the fungal component in the human microbiome suggests the need for new broad-coverage techniques. Methods We analyzed 2,085 18S rRNA gene sequences from the SILVA database for assay design. We generated and quantified plasmid standards using a qPCR-based approach. We evaluated assay coverage against 4,968 sequences and performed assay validation following the Minimum Information for Publication of Quantitative Real-Time PCR Experiments (MIQE guidelines. Results We designed FungiQuant, a TaqMan® qPCR assay targeting a 351 bp region in the fungal 18S rRNA gene. Our in silico analysis showed that FungiQuant is a perfect sequence match to 90.0% of the 2,617 fungal species analyzed. We showed that FungiQuant’s is 100% sensitive and its amplification efficiencies ranged from 76.3% to 114.5%, with r2-values of >0.99 against the 69 fungal species tested. Additionally, FungiQuant inter- and intra-run coefficients of variance ranged from Conclusions FungiQuant has comprehensive coverage against diverse fungi and is a robust quantification and detection tool for delineating between true fungal detection and non-target human DNA.

  8. Different methods of real-time PCR for detection of pseudorabies virus

    Directory of Open Access Journals (Sweden)

    Carolina Kymie Vasques Nonaka

    Full Text Available ABSTRACT: Pseudorabies (PR is a highly contagious viral disease of great animal health and economic importance in swine industry. The aim of this study was to evaluate different genomic regions, real-time PCR chemistries and equipment for the molecular diagnosis of PR. Eight primer pairs targeting four genes (gB, gC, gE, gD, three different qPCR chemistries (SybrGreen, hydrolysis probes and plexor and two equipment (ABI7500, Rotorgene 3000 were evaluated. Oligonucleotides targeting gB using hydrolysis probes showed the best performance after evaluating efficiency (99%, the detection limit (10-1.5 TCID50 mL-1 and diagnostic sensitivity and; therefore, those primers were selected for performance verification factors such as repeatability, reproducibility and robustness (1.39% variance between days, 24% variance between analysts and 4.07% variance in analysis error. The qPCR standardized and validated in this research proved to be reliable for the diagnosis of PR and may be used in diagnostic laboratories that follow ISO 17025 and ISO 16140.

  9. Detection of airborne genetically modified maize pollen by real-time PCR.

    Science.gov (United States)

    Folloni, Silvia; Kagkli, Dafni-Maria; Rajcevic, Bojan; Guimarães, Nilson C C; Van Droogenbroeck, Bart; Valicente, Fernando H; Van den Eede, Guy; Van den Bulcke, Marc

    2012-09-01

    The cultivation of genetically modified (GM) crops has raised numerous concerns in the European Union and other parts of the world about their environmental and economic impact. Especially outcrossing of genetically modified organisms (GMO) was from the beginning a critical issue as airborne pollen has been considered an important way of GMO dispersal. Here, we investigate the use of airborne pollen sampling combined with microscopic analysis and molecular PCR analysis as an approach to monitor GM maize cultivations in a specific area. Field trial experiments in the European Union and South America demonstrated the applicability of the approach under different climate conditions, in rural and semi-urban environment, even at very low levels of airborne pollen. The study documents in detail the sampling of GM pollen, sample DNA extraction and real-time PCR analysis. Our results suggest that this 'GM pollen monitoring by bioaerosol sampling and PCR screening' approach might represent an useful aid in the surveillance of GM-free areas, centres of origin and natural reserves. © 2012 Blackwell Publishing Ltd.

  10. Harmonization of Bordetella pertussis real-time PCR diagnostics in the United States in 2012.

    Science.gov (United States)

    Williams, Margaret M; Taylor, Thomas H; Warshauer, David M; Martin, Monte D; Valley, Ann M; Tondella, M Lucia

    2015-01-01

    Real-time PCR (rt-PCR) is an important diagnostic tool for the identification of Bordetella pertussis, Bordetella holmesii, and Bordetella parapertussis. Most U.S. public health laboratories (USPHLs) target IS481, present in 218 to 238 copies in the B. pertussis genome and 32 to 65 copies in B. holmesii. The CDC developed a multitarget PCR assay to differentiate B. pertussis, B. holmesii, and B. parapertussis and provided protocols and training to 19 USPHLs. The 2012 performance exercise (PE) assessed the capability of USPHLs to detect these three Bordetella species in clinical samples. Laboratories were recruited by the Wisconsin State Proficiency Testing program through the Association of Public Health Laboratories, in partnership with the CDC. Spring and fall PE panels contained 12 samples each of viable Bordetella and non-Bordetella species in saline. Fifty and 53 USPHLs participated in the spring and fall PEs, respectively, using a variety of nucleic acid extraction methods, PCR platforms, and assays. Ninety-six percent and 94% of laboratories targeted IS481 in spring and fall, respectively, in either singleplex or multiplex assays. In spring and fall, respectively, 72% and 79% of USPHLs differentiated B. pertussis and B. holmesii and 68% and 72% identified B. parapertussis. IS481 cycle threshold (CT) values for B. pertussis samples had coefficients of variation (CV) ranging from 10% to 28%. Of the USPHLs that differentiated B. pertussis and B. holmesii, sensitivity was 96% and specificity was 95% for the combined panels. The 2012 PE demonstrated increased harmonization of rt-PCR Bordetella diagnostic protocols in USPHLs compared to that of the previous survey.

  11. Performance of a real-time PCR assay for the rapid identification of Mycobacterium species.

    Science.gov (United States)

    Wang, Hye-young; Kim, Hyunjung; Kim, Sunghyun; Kim, Do-kyoon; Cho, Sang-Nae; Lee, Hyeyoung

    2015-01-01

    Mycobacteria cause a variety of illnesses that differ in severity and public health implications. The differentiation of Mycobacterium tuberculosis (MTB) from nontuberculous mycobacteria (NTM) is of primary importance for infection control and choice of antimicrobial therapy. The diagnosis of diseases caused by NTM is difficult because NTM species are prevalent in the environment and because they have fastidious properties. In the present study, we evaluated 279 clinical isolates grown in liquid culture provided by The Catholic University of Korea, St. Vincent's Hospital using real-time PCR based on mycobacterial rpoB gene sequences. The positive rate of real-time PCR assay accurately discriminated 100% (195/195) and 100% (84/84) between MTB and NTM species. Comparison of isolates identified using the MolecuTech REBA Myco-ID(®) and Real Myco-ID® were completely concordant except for two samples. Two cases that were identified as mixed infection (M. intracellulare-M. massiliense and M. avium-M. massiliense co-infection) by PCRREBA assay were only detected using M. abscessus-specific probes by Real Myco-ID(®). Among a total of 84 cases, the most frequently identified NTM species were M. intracellulare (n=38, 45.2%), M. avium (n=18, 23.7%), M. massiliense (n=10, 13.2%), M. fortuitum (n=5, 6%), M. abscessus (n=3, 3.9%), M. gordonae (n=3, 3.9%), M. kansasii (n=2, 2.4%), M. mucogenicum (n=2, 2.4%), and M. chelonae (n= 1, 1.2%). Real Myco-ID(®) is an efficient tool for the rapid detection of NTM species as well as MTB and sensitive and specific and comparable to conventional methods.

  12. Easy-to-use strategy for reference gene selection in quantitative real-time PCR experiments.

    Science.gov (United States)

    Klenke, Stefanie; Renckhoff, Kristina; Engler, Andrea; Peters, Jürgen; Frey, Ulrich H

    2016-12-01

    Real-time PCR is an indispensable technique for mRNA expression analysis but conclusions depend on appropriate reference gene selection. However, while reference gene selection has been a topic of publications, this issue is often disregarded when measuring target mRNA expression. Therefore, we (1) evaluated the frequency of appropriate reference gene selection, (2) suggest an easy-to-use tool for least variability reference gene selection, (3) demonstrate application of this tool, and (4) show effects on target gene expression profiles. All 2015 published articles in Naunyn-Schmiedeberg's Archives of Pharmacology were screened for the use of quantitative real-time PCR analysis and selection of reference genes. Target gene expression (Vegfa, Grk2, Sirt4, and Timp3) in H9c2 cells was analyzed following various interventions (hypoxia, hyperglycemia, and/or isoflurane exposure with and without subsequent hypoxia) in relation to putative reference genes (Actb, Gapdh, B2m, Sdha, and Rplp1) using the least variability method vs. an arbitrarily selected but established reference gene. In the vast majority (18 of 21) of papers, no information was provided regarding selection of an appropriate reference gene. In only 1 of 21 papers, a method of appropriate reference gene selection was described and in 2 papers reference gene selection remains unclear. The method of reference gene selection had major impact on interpretation of target gene expression. With hypoxia, for instance, the least variability gene was Rplp1 and target gene expression (Vefga) heavily showed a 2-fold up-regulation (p = 0.022) but no change (p = 0.3) when arbitrarily using Gapdh. Frequency of appropriate reference gene selection in this journal is low, and we propose our strategy for reference gene selection as an easy tool for proper target gene expression.

  13. Detection and quantification of Cladosporium in aerosols by real-time PCR.

    Science.gov (United States)

    Zeng, Qing-Yin; Westermark, Sven-Olof; Rasmuson-Lestander, Asa; Wang, Xiao-Ru

    2006-01-01

    Cladosporium is one of the most common airborne molds found in indoor and outdoor environments. Cladosporium spores are important aeroallergens, and prolonged exposure to elevated spore concentrations can provoke chronic allergy and asthma. To accurately quantify the levels of Cladosporium in indoor and outdoor environments, two real-time PCR systems were developed in this study. The two real-time PCR systems are highly specific and sensitive for Cladosporium detection even in a high background of other fungal DNAs. These methods were employed to quantify Cladosporium in aerosols of five different indoor environments. The investigation revealed a high spore concentration of Cladosporium (10(7) m(-3)) in a cow barn that accounted for 28-44% of the airborne fungal propagules. In a countryside house that uses firewood for heating and in a paper and pulp factory, Cladosporium was detected at 10(4) spores m(-3), which accounted for 2-6% of the fungal propagules in the aerosols. The concentrations of Cladosporium in these three indoor environments far exceeded the medical borderline level (3000 spores m(-3)). In a power station and a fruit and vegetable storage, Cladosporium was found to be a minor component in the aerosols, accounted for 0.01-0.1% of the total fungal propagules. These results showed that monitoring Cladosporium in indoor environments is more important than in outdoor environments from the public health point of view. Cladosporium may not be the dominant fungi in some indoor environments, but its concentration could still be exceeding the threshold value for clinical significance. The methods developed in this study could facilitate accurate detection and quantification of Cladosporium for public health related risk assessment.

  14. Detection of methylation in promoter sequences by melting curve analysis-based semiquantitative real time PCR

    Directory of Open Access Journals (Sweden)

    Lázcoz Paula

    2008-02-01

    Full Text Available Abstract Background We present two melting curve analysis (MCA-based semiquantitative real time PCR techniques to detect the promoter methylation status of genes. The first, MCA-MSP, follows the same principle as standard MSP but it is performed in a real time thermalcycler with results being visualized in a melting curve. The second, MCA-Meth, uses a single pair of primers designed with no CpGs in its sequence. These primers amplify both unmethylated and methylated sequences. In clinical applications the MSP technique has revolutionized methylation detection by simplifying the analysis to a PCR-based protocol. MCA-analysis based techniques may be able to further improve and simplify methylation analyses by reducing starting DNA amounts, by introducing an all-in-one tube reaction and by eliminating a final gel stage for visualization of the result. The current study aimed at investigating the feasibility of both MCA-MSP and MCA-Meth in the analysis of promoter methylation, and at defining potential advantages and shortcomings in comparison to currently implemented techniques, i.e. bisulfite sequencing and standard MSP. Methods The promoters of the RASSF1A (3p21.3, BLU (3p21.3 and MGMT (10q26 genes were analyzed by MCA-MSP and MCA-Meth in 13 astrocytoma samples, 6 high grade glioma cell lines and 4 neuroblastoma cell lines. The data were compared with standard MSP and validated by bisulfite sequencing. Results Both, MCA-MSP and MCA-Meth, successfully determined promoter methylation. MCA-MSP provided information similar to standard MSP analyses. However the analysis was possible in a single tube and avoided the gel stage. MCA-Meth proved to be useful in samples with intermediate methylation status, reflected by a melting curve position shift in dependence on methylation extent. Conclusion We propose MCA-MSP and MCA-Meth as alternative or supplementary techniques to MSP or bisulfite sequencing.

  15. Development and validation of real-time PCR for rapid detection of Mecistocirrus digitatus.

    Directory of Open Access Journals (Sweden)

    Subhra Subhadra

    Full Text Available Hematophagous activity of Mecistocirrus digitatus, which causes substantial blood and weight loss in large ruminants, is an emerging challenge due to the economic loss it brings to the livestock industry. Infected animals are treated with anthelmintic drugs, based on the identification of helminth species and the severity of infection; however, traditional methods such as microscopic identification and the counting of eggs for diagnosis and determination of level of infection are laborious, cumbersome and unreliable. To facilitate the detection of this parasite, a SYBR green-based real-time PCR was standardized and validated for the detection of M. digitatus infection in cattle and buffaloes. Oligonucleotides were designed to amplify partial Internal Transcribed Spacer (ITS-1 sequence of M. digitatus. The specificity of the primers was confirmed by non-amplification of DNA extracted from other commonly occurring gastrointestinal nematodes in ruminants. Plasmids were ligated with partial ITS-1 sequence of M. digitatus, serially diluted (hundred fold and used as standards in the real-time PCR assay. The quantification cycle (Cq values were plotted against the standard DNA concentration to produce a standard curve. The assay was sensitive enough to detect one plasmid containing the M. digitatus DNA. Clinical application of this assay was validated by testing the DNA extracted from the faeces of naturally infected cattle (n = 40 and buffaloes (n = 25. The results were compared with our standard curve to calculate the quantity of M. digitatus in each faecal sample. The Cq value of the assay depicted a strong linear relationship with faecal DNA content, with a regression coefficient of 0.984 and efficiency of 99%. This assay has noteworthy advantages over the conventional methods of diagnosis because it is more specific, sensitive and reliable.

  16. Sex ratio determination in bovine semen: a new approach by quantitative real time PCR.

    Science.gov (United States)

    Parati, K; Bongioni, G; Aleandri, R; Galli, A

    2006-12-01

    Sex preselection of livestock offspring in cattle represents, nowadays, a big potential for genetic improvement and market demand satisfaction. Sperm sorting by flow cytometer provides a powerful tool for artificial insemination and production of predefined sexed embryos but, an accurate verification of the yield of sperm separation remains essential for a field application of this technique or for improvement and validation of other related semen sexing technologies. In this work a new method for the determination of the proportion of X- and Y-bearing spermatozoa in bovine semen sample was developed by real time PCR. Two sets of primers and internal TaqMan probes were designed on specific X- and Y-chromosome genes. To allow a direct quantification, a standard reference was established using two plasmid cDNA clones (ratio 1:1) for the specific gene targets. The method was validated by a series of accuracy, repeatability and reproducibility assays and by testing two sets of sorted and unsorted semen samples. A high degree of accuracy (98.9%), repeatability (CV=2.58%) and reproducibility (CV=2.57%) was shown. The results of X- and Y-sorted semen samples analysed by real time PCR and by flow cytometric reanalysis showed no significant difference (P>0.05). The evaluation of X-chromosome bearing sperms content in unsorted samples showed an average of 51.11+/-0.56% for ejaculates and 50.17+/-0.58% for the commercial semen. This new method for quantification of the sexual chromosome content in spermatozoa demonstrated to be rapid and reliable, providing a valid support to the sperm sexing technologies.

  17. Detection and enumeration of Dekkera anomala in beer, cola, and cider using real-time PCR.

    Science.gov (United States)

    Gray, S R; Rawsthorne, H; Dirks, B; Phister, T G

    2011-04-01

    In this article, a quantitative real-time PCR assay for detection and enumeration of the spoilage yeast Dekkera anomala in beer, cola, apple cider, and brewing wort is presented as an improvement upon existing detection methods, which are very time-consuming and not always accurate.   Primers were designed to exclude other organisms common in these beverages, and the assay was linear over 6 log units of cell concentrations. The addition of large amounts of non-target yeast DNA did not affect the efficiency of this assay. A standard curve of known DNA was established by plotting the C(t) values obtained from the QPCR against the log of plate counts on yeast peptone dextrose medium and unknowns showed exceptional correlation when tested against this standard curve. The assay was found to detect D. anomala at levels of 10-14 CFU ml⁻¹ in either cola or beer and at levels of 9·4-25·0 CFU ml⁻¹ in apple cider. The assay was also used to follow the growth of D. anomala in brewing wort. The results indicate that real-time PCR is an effective tool for rapid, accurate detection and quantitation of D. anomala in beer, cola and apple cider. This method gives a faster and more efficient technique to screen beer, cola, and cider samples and reduce spoilage by D. anomala. Faster screening may allow for significant reduction in economic loss because of reduced spoilage. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  18. Estrogen receptors alpha and beta in rat placenta: detection by RT-PCR, real time PCR and Western blotting

    Directory of Open Access Journals (Sweden)

    Al-Bader Maie D

    2006-03-01

    Full Text Available Abstract Background High levels of estrogens during pregnancy not only retard placental and fetal growth but can lead to reproductive tract abnormalities in male progeny. Estrogens act through estrogen receptors (ER to modulate the transcription of target genes. These ER exist in two isoforms, ER alpha and ER beta and recently several variants of these isoforms have been identified. Methods The expressions of ER isoforms and variants have been studied in rat placenta at 16, 19 and 21 days gestation (dg. Gene expression was assessed using RT-PCR and real time PCR while protein expression was studied using Western blotting followed by immunodetection. Placental homogenates were probed with: a monoclonal antibody raised against the steroid binding domain of the ER alpha (ER alpha -S, a monoclonal antibody raised against the hinge region of ER alpha (ER alpha -H and a polyclonal antibody raised against the amino terminus of ER beta. Results ER alpha and ER beta mRNA and protein were detected from as early as 16 dg. Two PCR products were detected for ER alpha, one for the wild type ER alpha, and a smaller variant. Real time PCR results suggested the presence of a single product for ER beta. The antibodies used for detection of ER alpha protein both identified a single 67 kDa isoform; however a second 54 kDa band, which may be an ER alpha variant, was identified when using the ER alpha -H antibody. The abundance of both ER alpha bands decreased significantly between 16 and 19 dg. As for ER beta, four bands (76, 59, 54 and 41 kDa were detected. The abundance of the 59 and 54 kDa bands decreased significantly between 16 and 19 dg. Conclusion This study shows that both ER protein isoforms and their variants are present in rat placenta. The decrease in their expression near parturition suggests that the placenta may be relatively unresponsive to estrogens at this stage.

  19. In-house validation and quality control of real-time PCR methods for GMO detection: a practical approach.

    Science.gov (United States)

    Ciabatti, I; Froiio, A; Gatto, F; Amaddeo, D; Marchesi, U

    2006-01-01

    GMO detection and quantification methods in the EU are mainly based on real-time PCR. The analytical methods in use must be validated, first on an intra-laboratory scale and through a collaborative trial thereafter. Since a consensual protocol for intra-laboratory validation of real-time PCR methods is lacking, we provide a practical approach for the in-house validation of quantitative real-time PCR methods, establishing acceptability criteria and quality controls for PCR runs. Parameters such as limit of detection, limit of quantification, precision, trueness, linear dynamic range, PCR efficiency, robustness and specificity are considered. The protocol is sufficiently detailed to be directly applicable, increases the reliability of results and their harmonization among different laboratories, and represents a necessary preliminary step before proceeding to a time-consuming and costly full validation study.

  20. Development and validation of a real-time PCR assay for the detection of anguillid herpesvirus 1.

    Science.gov (United States)

    van Beurden, S J; Voorbergen-Laarman, M A; Roozenburg, I; van Tellingen, J; Haenen, O L M; Engelsma, M Y

    2016-01-01

    Anguillid herpesvirus 1 (AngHV1) causes a haemorrhagic disease with increased mortality in wild and farmed European eel, Anguilla anguilla (L.) and Japanese eel Anguilla japonica, Temminck & Schlegel). Detection of AngHV1 is currently based on virus isolation in cell culture, antibody-based typing assays or conventional PCR. We developed, optimized and concisely validated a diagnostic TaqMan probe based real-time PCR assay for the detection of AngHV1. The primers and probe target AngHV1 open reading frame 57, encoding the capsid protease and scaffold protein. Compared to conventional PCR, the developed real-time PCR is faster, less labour-intensive and has a reduced risk of cross-contamination. The real-time PCR assay was shown to be analytically sensitive and specific and has a high repeatability, efficiency and r(2) -value. The diagnostic performance of the assay was determined by testing 10% w/v organ suspensions and virus cultures from wild and farmed European eels from the Netherlands by conventional and real-time PCR. The developed real-time PCR assay is a useful tool for the rapid and sensitive detection of AngHV1 in 10% w/v organ suspensions from wild and farmed European eels.

  1. Evaluation of real-time RT-PCR assays for detection and quantification of norovirus genogroups I and II.

    Science.gov (United States)

    Rupprom, Kitwadee; Chavalitshewinkoon-Petmitr, Porntip; Diraphat, Pornphan; Kittigul, Leera

    2017-02-20

    Noroviruses are the leading cause of acute gastroenteritis in humans. Real-time reverse transcription-polymerase chain reaction (real-time RT-PCR) is a promising molecular method for the detection of noroviruses. In this study, the performance of three TaqMan real-time RT-PCR assays was assessed, which were one commercially available real-time RT-PCR kit (assay A: Norovirus Real Time RT-PCR kit) and two in-house real-time RT-PCR assays (assay B: LightCycler RNA Master Hybprobe and assay C: RealTime ready RNA Virus Master). Assays A and B showed higher sensitivity than assay C for norovirus GI, while they all had the same sensitivity (10(3) DNA copies/mL) for GII DNA standard controls. Assay B had the highest efficiency for both genogroups. No cross-reactivity was observed among GI and GII noroviruses, rotavirus, hepatitis A virus, and poliovirus. The detection rates of these assays in GI and GII norovirus-positive fecal samples were not significantly different. However, the mean quantification cycle (Cq) value of assay B for GII was lower than assays A and C with statistical significance (P-value, 0.000). All three real-time RT-PCR assays could detect a variety of noroviruses including GI.2, GII.2, GII.3, GII.4, GII.6, GII.12, GII.17, and GII.21. This study suggests assay B as a suitable assay for the detection and quantification of noroviruses GI and GII due to good analytical sensitivity and higher performance to amplify norovirus on DNA standard controls and clinical samples.

  2. First-trimester fetal sex determination in maternal serum using real-time PCR.

    Science.gov (United States)

    Costa, J M; Benachi, A; Gautier, E; Jouannic, J M; Ernault, P; Dumez, Y

    2001-12-01

    Fetal sex prediction can be achieved using PCR targeted at the SRY gene by analysing cell-free fetal DNA in maternal serum. Unfortunately, the results reported to date show a lack of sensitivity, especially during the first trimester of pregnancy. Therefore, determination of fetal sex by maternal serum analysis could not replace karyotype analysis following chorionic villus sampling. A new highly sensitive real-time PCR was developed to detect an SRY gene sequence in maternal serum. Analysis was performed on 121 pregnant women during the first trimester of pregnancy (mean gestational age: 11.8 weeks). Among them, 51 had at least one previous male-bearing pregnancy. Results were compared with fetal sex. SRY PCR analysis of maternal serum was in complete concordance with fetal sex. Among the 121 pregnant women, 61 were bearing a male fetus and 60 a female fetus. No false-negative results were observed. Furthermore, no false-positive results occurred, even though 27 women carrying a female fetus during the current pregnancy had at least one previous male-bearing pregnancy. This study demonstrates that a reliable, non-invasive sex determination can be achieved by PCR analysis of maternal serum during the first trimester of pregnancy. This non-invasive approach for fetal sex prediction should have great implications in the management of pregnant women who are carriers of an X-linked genetic disorder. Prenatal diagnosis might thus be performed for male fetuses only, avoiding invasive procedures and the risk of the loss of female fetuses.

  3. The quantification of spermatozoa by real-time quantitative PCR, spectrophotometry, and spermatophore cap size.

    Science.gov (United States)

    Doyle, Jacqueline M; McCormick, Cory R; DeWoody, J Andrew

    2011-01-01

    Many animals, such as crustaceans, insects, and salamanders, package their sperm into spermatophores, and the number of spermatozoa contained in a spermatophore is relevant to studies of sexual selection and sperm competition. We used two molecular methods, real-time quantitative polymerase chain reaction (RT-qPCR) and spectrophotometry, to estimate sperm numbers from spermatophores. First, we designed gene-specific primers that produced a single amplicon in four species of ambystomatid salamanders. A standard curve generated from cloned amplicons revealed a strong positive relationship between template DNA quantity and cycle threshold, suggesting that RT-qPCR could be used to quantify sperm in a given sample. We then extracted DNA from multiple Ambystoma maculatum spermatophores, performed RT-qPCR on each sample, and estimated template copy numbers (i.e. sperm number) using the standard curve. Second, we used spectrophotometry to determine the number of sperm per spermatophore by measuring DNA concentration relative to the genome size. We documented a significant positive relationship between the estimates of sperm number based on RT-qPCR and those based on spectrophotometry. When these molecular estimates were compared to spermatophore cap size, which in principle could predict the number of sperm contained in the spermatophore, we also found a significant positive relationship between sperm number and spermatophore cap size. This linear model allows estimates of sperm number strictly from cap size, an approach which could greatly simplify the estimation of sperm number in future studies. These methods may help explain variation in fertilization success where sperm competition is mediated by sperm quantity.

  4. Assessing the performance capabilities of LRE-based assays for absolute quantitative real-time PCR.

    Directory of Open Access Journals (Sweden)

    Robert G Rutledge

    potential to fundamentally transform how real-time qPCR is conducted.

  5. Increased efficacy for in-house validation of real-time PCR GMO detection methods.

    Science.gov (United States)

    Scholtens, I M J; Kok, E J; Hougs, L; Molenaar, B; Thissen, J T N M; van der Voet, H

    2010-03-01

    To improve the efficacy of the in-house validation of GMO detection methods (DNA isolation and real-time PCR, polymerase chain reaction), a study was performed to gain insight in the contribution of the different steps of the GMO detection method to the repeatability and in-house reproducibility. In the present study, 19 methods for (GM) soy, maize canola and potato were validated in-house of which 14 on the basis of an 8-day validation scheme using eight different samples and five on the basis of a more concise validation protocol. In this way, data was obtained with respect to the detection limit, accuracy and precision. Also, decision limits were calculated for declaring non-conformance (>0.9%) with 95% reliability. In order to estimate the contribution of the different steps in the GMO analysis to the total variation variance components were estimated using REML (residual maximum likelihood method). From these components, relative standard deviations for repeatability and reproducibility (RSD(r) and RSD(R)) were calculated. The results showed that not only the PCR reaction but also the factors 'DNA isolation' and 'PCR day' are important factors for the total variance and should therefore be included in the in-house validation. It is proposed to use a statistical model to estimate these factors from a large dataset of initial validations so that for similar GMO methods in the future, only the PCR step needs to be validated. The resulting data are discussed in the light of agreed European criteria for qualified GMO detection methods.

  6. Application of PCR and real-time PCR for monitoring cyanobacteria, Microcystis spp. and Cylindrospermopsis raciborskii in Macau freshwater reservoir

    Science.gov (United States)

    Zhang, Weiying; Lou, Inchio; Ung, Wai Kin; Kong, Yijun; Mok, Kai Meng

    2014-06-01

    Freshwater algal blooms have become a growing concern world-wide. They are caused by a high level of cyanobacteria, predominantly Microcystis spp. and Cylindrospermopsis raciborskii, which can produce microcystin and cylindrospermopsin, respectively. Longtime exposure to these cyanotoxins may affect public health, thus reliable detection, quantification, and enumeration of these harmful algae species has become a priority in water quality management. Traditional manual enumeration of algal bloom cells primarily involves microscopic identification which limited by inaccuracy and time-consumption.With the development of molecular techniques and an increasing number of microbial sequences available in the Genbank database, the use of molecular methods can be used for more rapid, reliable, and accurate detection and quantification. In this study, multiplex polymerase chain reaction (PCR) and real-time quantitative PCR (qPCR) techniques were developed and applied for monitoring cyanobacteria Microcystis spp. and C. raciborskii in the Macau Storage Reservoir (MSR). The results showed that the techniques were successful for identifying and quantifying the species in pure cultures and mixed cultures, and proved to be a potential application for water sampling in MSR. When the target species were above 1 million cells/L, similar cell numbers estimated by microscopic enumeration and qPCR were obtained. Further quantification in water samples indicated that the ratio of the estimated number of cell by microscopy and qPCR was 0.4-12.9 for cyanobacteria and 0.2-3.9 for C. raciborskii. However, Microcystis spp. was not observed by manual enumeration, while it was detected at low levels by qPCR, suggesting that qPCR is more sensitive and accurate. Thus the molecular approaches provide an additional reliable monitoring option to traditional microscopic enumeration for the ecosystems monitoring program.

  7. The performance of semi-quantitative differential PCR is similar to that of real-time PCR for the detection of the MYCN gene in neuroblastomas

    Directory of Open Access Journals (Sweden)

    A.C.M.F. Souza

    2009-09-01

    Full Text Available Amplification of the MYCN gene in neuroblastomas is a potent biological marker of highly aggressive tumors, which are invariably fatal unless sound clinical management is applied. To determine the usefulness of semi-quantitative differential PCR (SQ-PCR for accurate quantification of MYCN gene copy number, we evaluated the analytical performance of this method by comparing the results obtained with it for 101 tumor samples of neuroblastoma to that obtained by absolute and relative real-time PCR. Similar results were obtained for 100 (99% samples, no significant difference was detected between the median log10 MYCN copy number (1.53 by SQ-PCR versus 1.55 by absolute real-time PCR, and the results of the two assays correlated closely (r = 0.8, Pearson correlation; P < 0.001. In the comparison of SQ-PCR and relative real-time PCR, SQ-PCR versus relative real-time PCR concordant results were found in 100 (99% samples, no significant difference was found in median log10 MYCN copy number (1.53 by SQ-PCR versus 1.27 by relative real-time PCR, and the results of the two assays correlated closely (r = 0.8, Pearson correlation; P < 0.001. These findings indicate that the performance of SQ-PCR was comparable to that of real-time PCR for the amplification and quantification of MYCN copy number. Thus, SQ-PCR can be reliably used as an alternative assay in laboratories without facilities for real-time PCR.

  8. [Evaluation of reference genes for quantitative real-time PCR normalization in cotton bollworm, Helicoverna armigera].

    Science.gov (United States)

    Chandra, G Sharath; Asokan, R; Manamohan, M; Kumar, N K K; Sita, T

    2014-01-01

    Reverse-transcription quantitative real-time PCR (RT-qPCR), a sensitive technique is being extensively employed in quantification of gene expression. However this requires normalization with suitable reference gene (RG) which is crucial in minimizing inter sample variations. Information regarding suitable RG is scarce in general and more so in insects, including the cotton bollworm, Helicoverpa armigera, an economically important pest. In management of this pest RNA interference (RNAi), is perceived as a potential tool, which is achieved by double-stranded RNA (dsRNA) delivery. These studies demand accurate quantification of gene silencing. In this study we assessed the suitability of five RGs viz. β-actin (ACTB), 18S rRNA (18S), glyceraldehyde-3-phosphate dehydrogenase (GAPDH), β-tubulin (TUB) and elongation fator-1-alfa (EF1-α) for gene expression studies in dsRNA treatment and across different developmental stages of H. armigera and ranked using geNorm, NormFinder and BestKeeper software programs. Data analysis revealed that best ranked RGs were varied in dsRNA treatment and in developmental stages. Under dsRNA treatment, 18S and GAPDH were more stable whereas, TUB and GAPDH were more stable across developmental stages. We also demonstrate that inappropriate selection of RG led to erroneous estimation of the target gene, chymotrypsin, expression. These results facilitate accurate quantification of gene expression in H. armigera.

  9. Use of real-time PCR to evaluate two DNA extraction methods from food

    Directory of Open Access Journals (Sweden)

    Maria Regina Branquinho

    2012-03-01

    Full Text Available The DNA extraction is a critical step in Genetically Modified Organisms analysis based on real-time PCR. In this study, the CTAB and DNeasy methods provided good quality and quantity of DNA from the texturized soy protein, infant formula, and soy milk samples. Concerning the Certified Reference Material consisting of 5% Roundup Ready® soybean, neither method yielded DNA of good quality. However, the dilution test applied in the CTAB extracts showed no interference of inhibitory substances. The PCR efficiencies of lectin target amplification were not statistically different, and the coefficients of correlation (R² demonstrated high degree of correlation between the copy numbers and the threshold cycle (Ct values. ANOVA showed suitable adjustment of the regression and absence of significant linear deviations. The efficiencies of the p35S amplification were not statistically different, and all R² values using DNeasy extracts were above 0.98 with no significant linear deviations. Two out of three R² values using CTAB extracts were lower than 0.98, corresponding to lower degree of correlation, and the lack-of-fit test showed significant linear deviation in one run. The comparative analysis of the Ct values for the p35S and lectin targets demonstrated no statistical significant differences between the analytical curves of each target.

  10. Statistical assessment of DNA extraction reagent lot variability in real-time quantitative PCR

    Science.gov (United States)

    Bushon, R.N.; Kephart, C.M.; Koltun, G.F.; Francy, D.S.; Schaefer, F. W.; Lindquist, H.D. Alan

    2010-01-01

    Aims: The aim of this study was to evaluate the variability in lots of a DNA extraction kit using real-time PCR assays for Bacillus anthracis, Francisella tularensis and Vibrio cholerae. Methods and Results: Replicate aliquots of three bacteria were processed in duplicate with three different lots of a commercial DNA extraction kit. This experiment was repeated in triplicate. Results showed that cycle threshold values were statistically different among the different lots. Conclusions: Differences in DNA extraction reagent lots were found to be a significant source of variability for qPCR results. Steps should be taken to ensure the quality and consistency of reagents. Minimally, we propose that standard curves should be constructed for each new lot of extraction reagents, so that lot-to-lot variation is accounted for in data interpretation. Significance and Impact of the Study: This study highlights the importance of evaluating variability in DNA extraction procedures, especially when different reagent lots are used. Consideration of this variability in data interpretation should be an integral part of studies investigating environmental samples with unknown concentrations of organisms. ?? 2010 The Society for Applied Microbiology.

  11. Influence of segmenting fluids on efficiency, crossing point and fluorescence level in real time quantitative PCR.

    Science.gov (United States)

    Walsh, E J; King, C; Grimes, R; Gonzalez, A

    2006-03-01

    The two-phase segmented flow approach to the processing and quantitative analysis of biological samples in microdevices offers significant advantages over the single-phase continuous flow methodology. Despite this, little is known about the compatibility of samples and reactants with segmenting fluids, although a number of investigators have reported reduced yield and inhibition of enzymatic reactions depending on the segmenting fluid employed. The current study addresses the compatibility of various segmenting fluids with real time quantitative PCR to understand the physicochemical requirements of this important reaction in biotechnology. The results demonstrate that creating a static segmenting fluid/PCR mix interface has a negligible impact on the reaction efficiency, crossing threshold and end fluorescence levels using a variety of segmenting fluids. The implication is then that the previously reported inhibitory effects are the result of the dynamic motion between the segmenting fluid and the sample in continuously flowing systems. The results presented here are a first step towards understanding the limitations of the segmented flow methodology, which are necessary to bring this approach into mainstream use.

  12. Real-time multiplex PCR assay for detection of Yersinia pestis and Yersinia pseudotuberculosis.

    Science.gov (United States)

    Matero, Pirjo; Pasanen, Tanja; Laukkanen, Riikka; Tissari, Päivi; Tarkka, Eveliina; Vaara, Martti; Skurnik, Mikael

    2009-01-01

    A multiplex real-time polymerase chain reaction (PCR) assay was developed for the detection of Yersinia pestis and Yersinia pseudotuberculosis. The assay includes four primer pairs, two of which are specific for Y. pestis, one for Y. pestis and Y. pseudotuberculosis and one for bacteriophage lambda; the latter was used as an internal amplification control. The Y. pestis-specific target genes in the assay were ypo2088, a gene coding for a putative methyltransferase, and the pla gene coding for the plasminogen activator. In addition, the wzz gene was used as a target to specifically identify both Y. pestis and the closely related Y. pseudotuberculosis group. The primer and probe sets described for the different genes can be used either in single or in multiplex PCR assays because the individual probes were designed with different fluorochromes. The assays were found to be both sensitive and specific; the lower limit of the detection was 10-100 fg of extracted Y. pestis or Y. pseudotuberculosis total DNA. The sensitivity of the tetraplex assay was determined to be 1 cfu for the ypo2088 and pla probe labelled with FAM and JOE fluorescent dyes, respectively.

  13. Selection of Suitable Reference Genes for Quantitative Real-time PCR in Sapium sebiferum

    Directory of Open Access Journals (Sweden)

    Xue Chen

    2017-05-01

    Full Text Available Chinese tallow (Sapium sebiferum L. is a promising landscape and bioenergy plant. Measuring gene expression by quantitative real-time polymerase chain reaction (qRT-PCR can provide valuable information on gene function. Stably expressed reference genes for normalization are a prerequisite for ensuring the accuracy of the target gene expression level among different samples. However, the reference genes in Chinese tallow have not been systematically validated. In this study, 12 candidate reference genes (18S, GAPDH, UBQ, RPS15, SAND, TIP41, 60S, ACT7, PDF2, APT, TBP, and TUB were investigated with qRT-PCR in 18 samples, including those from different tissues, from plants treated with sucrose and cold stresses. The data were calculated with four common algorithms, geNorm, BestKeeper, NormFinder, and the delta cycle threshold (ΔCt. TIP41 and GAPDH were the most stable for the tissue-specific experiment, GAPDH and 60S for cold treatment, and GAPDH and UBQ for sucrose stresses, while the least stable genes were 60S, TIP41, and 18S respectively. The comprehensive results showed APT, GAPDH, and UBQ to be the top-ranked stable genes across all the samples. The stability of 60S was the lowest during all experiments. These selected reference genes were further validated by comparing the expression profiles of the chalcone synthase gene in Chinese tallow in different samples. The results will help to improve the accuracy of gene expression studies in Chinese tallow.

  14. Development and evaluation of a real-time one step Reverse-Transcriptase PCR for quantitation of Chandipura Virus

    Directory of Open Access Journals (Sweden)

    Tandale Babasaheb V

    2008-12-01

    Full Text Available Abstract Background Chandipura virus (CHPV, a member of family Rhabdoviridae was attributed to an explosive outbreak of acute encephalitis in children in Andhra Pradesh, India in 2003 and a small outbreak among tribal children from Gujarat, Western India in 2004. The case-fatality rate ranged from 55–75%. Considering the rapid progression of the disease and high mortality, a highly sensitive method for quantifying CHPV RNA by real-time one step reverse transcriptase PCR (real-time one step RT-PCR using TaqMan technology was developed for rapid diagnosis. Methods Primers and probe for P gene were designed and used to standardize real-time one step RT-PCR assay for CHPV RNA quantitation. Standard RNA was prepared by PCR amplification, TA cloning and run off transcription. The optimized real-time one step RT-PCR assay was compared with the diagnostic nested RT-PCR and different virus isolation systems [in vivo (mice in ovo (eggs, in vitro (Vero E6, PS, RD and Sand fly cell line] for the detection of CHPV. Sensitivity and specificity of real-time one step RT-PCR assay was evaluated with diagnostic nested RT-PCR, which is considered as a gold standard. Results Real-time one step RT-PCR was optimized using in vitro transcribed (IVT RNA. Standard curve showed linear relationship for wide range of 102-1010 (r2 = 0.99 with maximum Coefficient of variation (CV = 5.91% for IVT RNA. The newly developed real-time RT-PCR was at par with nested RT-PCR in sensitivity and superior to cell lines and other living systems (embryonated eggs and infant mice used for the isolation of the virus. Detection limit of real-time one step RT-PCR and nested RT-PCR was found to be 1.2 × 100 PFU/ml. RD cells, sand fly cells, infant mice, and embryonated eggs showed almost equal sensitivity (1.2 × 102 PFU/ml. Vero and PS cell-lines (1.2 × 103 PFU/ml were least sensitive to CHPV infection. Specificity of the assay was found to be 100% when RNA from other viruses or healthy

  15. Reverse transcriptase real-time PCR for detection and quantification of viable Campylobacter jejuni directly from poultry faecal samples

    DEFF Research Database (Denmark)

    Bui, Thanh Xuan; Wolff, Anders; Madsen, Mogens

    2012-01-01

    and quantification of viable Campylobacter jejuni directly from chicken faecal samples. The results of this method anda DNA-based quantitative real-time PCR (qPCR) method were compared with those of a bacterial culture method. Using bacterial culture andRT-qPCR methods, viable C. jejuni cells could be detected......Campylobacter spp. is the most common cause of bacterial diarrhoea in humans worldwide. Therefore, rapid and reliable methods fordetection and quantification of this pathogen are required. In this study, we have developed a reverse transcription quantitative real-time PCR(RT-qPCR) for detection...... for up to 5 days in both the C. jejuni spiked and the naturally contaminated faecalsamples. We found that no RT-qPCR signals were obtained when viable C. jejuni cells could not be counted by the culture method. In contrast,using a DNA-based qPCR method, dead or non-viable Campylobacter cells were...

  16. Detection of Actinobacillus pleuropneumoniae in pigs by real-time quantitative PCR for the apxIVA gene

    NARCIS (Netherlands)

    Tobias, T.J.; Bouma, A.; Klinkenberg, D.; Daemen, A.J.J.M.; Stegeman, J.A.; Wagenaar, J.A.; Duim, B.

    2012-01-01

    A real-time quantitative PCR (qPCR) for detection of the apxIVA gene of Actinobacillus pleuropneumoniae was validated using pure cultures of A. pleuropneumoniae and tonsillar and nasal swabs from experimentally inoculated Caesarean-derived/colostrum-deprived piglets and naturally infected

  17. Undergraduate Virology Exercises Demonstrate Conventional and Real-Time PCR Using Commercially Available HIV Primers and Noninfectious Target

    Science.gov (United States)

    Sulzinski, Michael A.; Wasilewski, Melissa A.; Farrell, James C.; Glick, David L.

    2009-01-01

    It is an extraordinary challenge to offer an undergraduate laboratory course in virology that teaches hands-on, relevant molecular biology techniques using nonpathogenic models of human virus detection. To our knowledge, there exists no inexpensive kits or reagent sets that are appropriate for demonstrating real-time PCR (RT-PCR) in an…

  18. Diagnosis of pulmonary infection with Toxoplasma gondii in immunocompromised HIV-positive patients by real-time PCR

    DEFF Research Database (Denmark)

    Petersen, E; Edvinsson, B; Lundgren, B

    2006-01-01

    The aim of the study presented here was to evaluate the use of PCR for improving the diagnosis of Toxoplasma gondii infection in immunocompromised hosts. Three hundred thirty-two bronchoalveolar lavage (BAL) fluid samples were analyzed by real-time PCR targeting a 529 bp element of T. gondii...

  19. A human fecal contamination index for ranking impaired recreational watersusing the HF183 quantitative real-time PCR method

    Science.gov (United States)

    Human fecal pollution of surface water remains a public health concern worldwide. As a result, there is a growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for recreational water quality risk managem...

  20. Data Acceptance Criteria for Standardized Human-Associated Fecal Source Identification Quantitative Real-Time PCR Methods

    Science.gov (United States)

    There is a growing interest in the application of human-associated fecal sourceidentification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data q...

  1. Development of a real-time PCR assay for the direct detection of Candida species causing Vulvovaginal candidiasis.

    Science.gov (United States)

    Tardif, Keith D; Schlaberg, Robert

    2017-01-25

    Identification of Candida species by traditional methods can be time-consuming and have limited analytical sensitivity. We developed a multiplex real-time PCR assay for detection and differentiation of Candida species causing vulvovaginal candidiasis (VVC). Overall, this PCR assay is a powerful diagnostic tool offering superior accuracy, sensitivity, and specificity.

  2. Detection of diarrhoea-causing protozoa in general practice patients in The Netherlands by multiplex real-time PCR

    NARCIS (Netherlands)

    ten Hove, R.; Schuurman, T.; Kooistra, M.; Moeller, L.; van Lieshout, L.; Verweij, J. J.

    2007-01-01

    The diagnostic value of a multiplex real-time PCR for the detection of Entamoeba histolytica, Giardia lamblia and Cryptosporidium parvum/Cryptosporidium hominis was evaluated by comparing the PCR results obtained with those of routinely performed microscopy of faecal samples from patients consulting

  3. EVALUATION OF A RAPID, QUANTITATIVE REAL-TIME PCR METHOD FOR ENUMERATION OF PATHOGENIC CANDIDA CELLS IN WATER

    Science.gov (United States)

    Quantitative Real-Time PCR (QRT-PCR) technology, incorporating fluorigenic 5' nuclease (TaqMan?) chemistry, was developed for the specific detection and quantification of six pathogenic species of Candida (C. albicans, C. tropicalis, C. krusei, C. parapsilosis, C. glabrata and C....

  4. A human fecal contamination index for ranking impaired recreational watersusing the HF183 quantitative real-time PCR method

    Science.gov (United States)

    Human fecal pollution of surface water remains a public health concern worldwide. As a result, there is a growing interest in the application of human-associated fecal source identification quantitative real-time PCR (qPCR) technologies for recreational water quality risk managem...

  5. Data Acceptance Criteria for Standardized Human-Associated Fecal Source Identification Quantitative Real-Time PCR Methods

    Science.gov (United States)

    There is a growing interest in the application of human-associated fecal sourceidentification quantitative real-time PCR (qPCR) technologies for water quality management. The transition from a research tool to a standardized protocol requires a high degree of confidence in data q...

  6. Detection of diarrhoea-causing protozoa in general practice patients in The Netherlands by multiplex real-time PCR

    NARCIS (Netherlands)

    ten Hove, R.; Schuurman, T.; Kooistra, M.; Moeller, L.; van Lieshout, L.; Verweij, J. J.

    2007-01-01

    The diagnostic value of a multiplex real-time PCR for the detection of Entamoeba histolytica, Giardia lamblia and Cryptosporidium parvum/Cryptosporidium hominis was evaluated by comparing the PCR results obtained with those of routinely performed microscopy of faecal samples from patients consulting

  7. Undergraduate Virology Exercises Demonstrate Conventional and Real-Time PCR Using Commercially Available HIV Primers and Noninfectious Target

    Science.gov (United States)

    Sulzinski, Michael A.; Wasilewski, Melissa A.; Farrell, James C.; Glick, David L.

    2009-01-01

    It is an extraordinary challenge to offer an undergraduate laboratory course in virology that teaches hands-on, relevant molecular biology techniques using nonpathogenic models of human virus detection. To our knowledge, there exists no inexpensive kits or reagent sets that are appropriate for demonstrating real-time PCR (RT-PCR) in an…

  8. Detection of Actinobacillus pleuropneumoniae in pigs by real-time quantitative PCR for the apxIVA gene

    NARCIS (Netherlands)

    Tobias, T.J.; Bouma, A.; Klinkenberg, D.; Daemen, A.J.J.M.; Stegeman, J.A.; Wagenaar, J.A.; Duim, B.

    2012-01-01

    A real-time quantitative PCR (qPCR) for detection of the apxIVA gene of Actinobacillus pleuropneumoniae was validated using pure cultures of A. pleuropneumoniae and tonsillar and nasal swabs from experimentally inoculated Caesarean-derived/colostrum-deprived piglets and naturally infected convention

  9. Duplex real-time PCR for rapid simultaneous detection of Batrachochytrium dendrobatidis and Batrachochytrium salamandrivorans in Amphibian samples.

    Science.gov (United States)

    Blooi, M; Pasmans, F; Longcore, J E; Spitzen-van der Sluijs, A; Vercammen, F; Martel, A

    2013-12-01

    Chytridiomycosis is a lethal fungal disease contributing to declines and extinctions of amphibian species worldwide. The currently used molecular screening tests for chytridiomycosis fail to detect the recently described species Batrachochytrium salamandrivorans. In this study, we present a duplex real-time PCR that allows the simultaneous detection of B. salamandrivorans and Batrachochytrium dendrobatidis. With B. dendrobatidis- and B. salamandrivorans-specific primers and probes, detection of the two pathogens in amphibian samples is possible, with a detection limit of 0.1 genomic equivalent of zoospores of both pathogens per PCR. The developed real-time PCR shows high degrees of specificity and sensitivity, high linear correlations (r(2) > 0.995), and high amplification efficiencies (>94%) for B. dendrobatidis and B. salamandrivorans. In conclusion, the described duplex real-time PCR can be used to detect DNA of B. dendrobatidis and B. salamandrivorans with highly reproducible and reliable results.

  10. TaqMan real-time PCR for detection and quantitation of squash leaf curl virus in cucurbits.

    Science.gov (United States)

    Kuan, Cheng-Ping; Huang, Hung-Chang; Chang, Chia-Che; Lu, Yi-Lin

    2012-02-01

    A real-time PCR assay based on the TaqMan chemistry was developed for reliable detection and quantitation of the squash leaf curl virus (SLCV) in melon and squash plants. This method was highly specific to SLCV and it was about one thousand times more sensitive than the conventional PCR method. The protocol of the real-time PCR established in this study enabled detection of as little as 10(2) copies of SLCV DNA with CP gene as the target. This TaqMan real-time PCR assay for detection and quantitation of SLCV would be a useful tool for application in quarantine and certification of SLCV in cucurbits as well as in the research of disease resistance and epidemiology.

  11. Sensitive detection of novel Indian isolate of BTV 21 using ns1 gene based real-time PCR assay

    Directory of Open Access Journals (Sweden)

    Gaya Prasad

    2013-06-01

    Full Text Available Aim: The study was conducted to develop ns1 gene based sensitive real-time RT-PCR assay for diagnosis of India isolates of bluetongue virus (BTV. Materials and Methods: The BTV serotype 21 isolate (KMNO7 was isolated from Andhra Pradesh and propagated in BHK-21 cell line in our laboratory. The Nucleic acid (dsRNA of virus was extracted using Trizol method and cDNA was prepared using a standard protocol. The cDNA was allowed to ns1 gene based group specific PCR to confirm the isolate as BTV. The viral RNA was diluted 10 folds and the detection limit of ns1 gene based RT-PCR was determined. Finally the tenfold diluted viral RNA was subjected to real-time RT-PCR using ns1 gene primer and Taq man probe to standardized the reaction and determine the detection limit. Results: The ns1 gene based group specific PCR showed a single 366bp amplicon in agarose gel electrophoresis confirmed the sample as BTV. The ns1 gene RT-PCR using tenfold diluted viral RNA showed the detection limit of 70.0 fg in 1%agarose gel electrophoresis. The ns1 gene based real time RT-PCR was successfully standardized and the detection limit was found to be 7.0 fg. Conclusion: The ns1 gene based real-time RT-PCR was successfully standardized and it was found to be 10 times more sensitive than conventional RT-PCR. Key words: bluetongue, BTV21, RT-PCR, Real time RT-PCR, ns1 gene [Vet World 2013; 6(8.000: 554-557

  12. Exploring valid reference genes for quantitative real-time PCR analysis in Sesamia inferens (Lepidoptera: Noctuidae.

    Directory of Open Access Journals (Sweden)

    Meng Sun

    Full Text Available The pink stem borer, Sesamia inferens, which is endemic in China and other parts of Asia, is a major pest of rice and causes significant yield loss in this host plant. Very few studies have addressed gene expression in S. inferens. Quantitative real-time PCR (qRT-PCR is currently the most accurate and sensitive method for gene expression analysis. In qRT-PCR, data are normalized using reference genes, which help control for internal differences and reduce error between samples. In this study, seven candidate reference genes, 18S ribosomal RNA (18S rRNA, elongation factor 1 (EF1, glyceraldehyde-3-phosphate dehydrogenase (GAPDH, ribosomal protein S13 (RPS13, ribosomal protein S20 (RPS20, tubulin (TUB, and β-actin (ACTB were evaluated for their suitability in normalizing gene expression under different experimental conditions. The results indicated that three genes (RPS13, RPS20, and EF1 were optimal for normalizing gene expression in different insect tissues (head, epidermis, fat body, foregut, midgut, hindgut, Malpighian tubules, haemocytes, and salivary glands. 18S rRNA, EF1, and GAPDH were best for normalizing expression with respect to developmental stages and sex (egg masses; first, second, third, fourth, fifth, and sixth instar larvae; male and female pupae; and one-day-old male and female adults. 18S rRNA, RPS20, and TUB were optimal for fifth instars exposed to different temperatures (-8, -6, -4, -2, 0, and 27°C. To validate this recommendation, the expression profile of a target gene heat shock protein 83 gene (hsp83 was investigated, and results showed the selection was necessary and effective. In conclusion, this study describes reference gene sets that can be used to accurately measure gene expression in S. inferens.

  13. Rapid detection of Listeria monocytogenes by real-time PCR in processed meat and dairy products.

    Science.gov (United States)

    Heo, Eun Jeong; Song, Bo Ra; Park, Hyun Jung; Kim, Young Jo; Moon, Jin San; Wee, Sung Hwan; Kim, Jin-Seok; Yoon, Yohan

    2014-03-01

    The objectives of this study were to evaluate the detection of Listeria monocytogenes in different ready-to-eat foods using real-time PCR (RT-PCR). Various concentrations (10(0) to 10(5) CFU/ml) of L. monocytogenes ATCC 19115 were inoculated into ham, sausage, ground meat, processed milk, cheese, and infant formula. L. monocytogenes ATCC 19115 in the samples was then enumerated on Oxford agar, and DNA was extracted from the samples before and after incubation at 36°C for 4 h. A set of primers and hybridization probe designed in this study was then used to detect the pathogen. The standard curve was then prepared by plotting cycle threshold values for each dilution versus L. monocytogenes cell counts (log CFU). The specificity of the set of primers and hybridization probe was appropriate. A 4-h incubation at 36°C before DNA extraction produced optimum standard curves in comparison to the results for a 0-h incubation. Thus, a 4-h incubation at 36°C was applied for monitoring L. monocytogenes in collected food samples. To monitor L. monocytogenes in foods, 533 samples (ham, 129; sausage, 226; ground meat, 72; processed cheese, 54; processed milk, 42; and infant formula, 10) were collected from retail markets and from the step before pasteurization in plants. Of all 533 samples, 4 samples (0.8%) showed positive signals in RT-PCR. Two samples from hams (1.6%) and two samples from sausages (0.9%) were determined to be positive for L. monocytogenes at processed meat and milk products.

  14. Exploring valid reference genes for quantitative real-time PCR analysis in Sesamia inferens (Lepidoptera: Noctuidae).

    Science.gov (United States)

    Sun, Meng; Lu, Ming-Xing; Tang, Xiao-Tian; Du, Yu-Zhou

    2015-01-01

    The pink stem borer, Sesamia inferens, which is endemic in China and other parts of Asia, is a major pest of rice and causes significant yield loss in this host plant. Very few studies have addressed gene expression in S. inferens. Quantitative real-time PCR (qRT-PCR) is currently the most accurate and sensitive method for gene expression analysis. In qRT-PCR, data are normalized using reference genes, which help control for internal differences and reduce error between samples. In this study, seven candidate reference genes, 18S ribosomal RNA (18S rRNA), elongation factor 1 (EF1), glyceraldehyde-3-phosphate dehydrogenase (GAPDH), ribosomal protein S13 (RPS13), ribosomal protein S20 (RPS20), tubulin (TUB), and β-actin (ACTB) were evaluated for their suitability in normalizing gene expression under different experimental conditions. The results indicated that three genes (RPS13, RPS20, and EF1) were optimal for normalizing gene expression in different insect tissues (head, epidermis, fat body, foregut, midgut, hindgut, Malpighian tubules, haemocytes, and salivary glands). 18S rRNA, EF1, and GAPDH were best for normalizing expression with respect to developmental stages and sex (egg masses; first, second, third, fourth, fifth, and sixth instar larvae; male and female pupae; and one-day-old male and female adults). 18S rRNA, RPS20, and TUB were optimal for fifth instars exposed to different temperatures (-8, -6, -4, -2, 0, and 27°C). To validate this recommendation, the expression profile of a target gene heat shock protein 83 gene (hsp83) was investigated, and results showed the selection was necessary and effective. In conclusion, this study describes reference gene sets that can be used to accurately measure gene expression in S. inferens.

  15. Reference gene selection for quantitative real-time PCR normalization in Quercus suber.

    Science.gov (United States)

    Marum, Liliana; Miguel, Andreia; Ricardo, Cândido P; Miguel, Célia

    2012-01-01

    The use of reverse transcription quantitative PCR technology to assess gene expression levels requires an accurate normalization of data in order to avoid misinterpretation of experimental results and erroneous analyses. Despite being the focus of several transcriptomics projects, oaks, and particularly cork oak (Quercus suber), have not been investigated regarding the identification of reference genes suitable for the normalization of real-time quantitative PCR data. In this study, ten candidate reference genes (Act, CACs, EF-1α, GAPDH, His3, PsaH, Sand, PP2A, ß-Tub and Ubq) were evaluated to determine the most stable internal reference for quantitative PCR normalization in cork oak. The transcript abundance of these genes was analysed in several tissues of cork oak, including leaves, reproduction cork, and periderm from branches at different developmental stages (1-, 2-, and 3-year old) or collected in different dates (active growth period versus dormancy). The three statistical methods (geNorm, NormFinder, and CV method) used in the evaluation of the most suitable combination of reference genes identified Act and CACs as the most stable candidates when all the samples were analysed together, while ß-Tub and PsaH showed the lowest expression stability. However, when different tissues, developmental stages, and collection dates were analysed separately, the reference genes exhibited some variation in their expression levels. In this study, and for the first time, we have identified and validated reference genes in cork oak that can be used for quantification of target gene expression in different tissues and experimental conditions and will be useful as a starting point for gene expression studies in other oaks.

  16. Reference gene selection for quantitative real-time PCR normalization in Quercus suber.

    Directory of Open Access Journals (Sweden)

    Liliana Marum

    Full Text Available The use of reverse transcription quantitative PCR technology to assess gene expression levels requires an accurate normalization of data in order to avoid misinterpretation of experimental results and erroneous analyses. Despite being the focus of several transcriptomics projects, oaks, and particularly cork oak (Quercus suber, have not been investigated regarding the identification of reference genes suitable for the normalization of real-time quantitative PCR data. In this study, ten candidate reference genes (Act, CACs, EF-1α, GAPDH, His3, PsaH, Sand, PP2A, ß-Tub and Ubq were evaluated to determine the most stable internal reference for quantitative PCR normalization in cork oak. The transcript abundance of these genes was analysed in several tissues of cork oak, including leaves, reproduction cork, and periderm from branches at different developmental stages (1-, 2-, and 3-year old or collected in different dates (active growth period versus dormancy. The three statistical methods (geNorm, NormFinder, and CV method used in the evaluation of the most suitable combination of reference genes identified Act and CACs as the most stable candidates when all the samples were analysed together, while ß-Tub and PsaH showed the lowest expression stability. However, when different tissues, developmental stages, and collection dates were analysed separately, the reference genes exhibited some variation in their expression levels. In this study, and for the first time, we have identified and validated reference genes in cork oak that can be used for quantification of target gene expression in different tissues and experimental conditions and will be useful as a starting point for gene expression studies in other oaks.

  17. Real Time Polymerase Chain Reaction (rt-PCR): A New Patent to Diagnostic Purposes for Paracoccidioidomycosis.

    Science.gov (United States)

    Rocha-Silva, Fabiana; Gomes, Luciana I; Gracielle-Melo, Cidiane; Goes, Alfredo M; Caligiorne, Rachel B

    2017-01-01

    Paracoccidioidomycosis (PCM) is a systemic mycosis caused by dimorphic fungi Paracoccidioides brasiliensis and Paracoccidioides lutzii. It is prevalent in Latin American, mainly in Brazil. Therefore, PCM has fundamental impact on the Brazilian global economy, especially in public health system, since it is affecting economical active population in different country regions. The present study aimed to standardize the Real Time-Polymerase Chain Reaction (rt-PCR) for an efficient and safe PCM diagnosis amplifying the recombinant protein PB27 gene, only expressed by specimens of Paracoccidioides genus. To standardize a methodology of rt-PCR using species-specific primers and probe designed for annealing in this specific region of the fungi´s genome, amplifying the recombinant protein PB27 gene, only expressed by specimens of Paracoccidioides genus. Followed by design in silico, experiments were performed in vitro to determine rt-PCR specificity, efficiency and genome detection limit. The primers and probe sequences were deposited in Brazilian Coordination of Technological Innovation and Transfer (CTIT), under patent reference number BR1020160078830. The present study demonstrated the rt-PCR applicability for support on diagnosis of paracoccidioidomycosis, presenting low cost, which makes it affordable for public health services in developing countries as Brazil. It is noteworthy that it is necessary to validate this methodology using clinical samples before to use as a safe method of diagnosis. A review of all patents related to this topic was performed and it was shown that, to date, there are no records of patent on kits for paracoccidioidomycosis´s diagnostic. Indeed, there is still a lot to go to reach this goal. The reaction developed was standardized and patented, opening perspectives to molecular diagnosis development for paracoccidioidomycosis, since rt-PCR can be applied to a broad spectrum of infectious diseases. It would need to be tested in biological

  18. Routes to improving the reliability of low level DNA analysis using real-time PCR

    Directory of Open Access Journals (Sweden)

    Burns Malcolm J

    2006-07-01

    Full Text Available Abstract Background Accurate quantification of DNA using quantitative real-time PCR at low levels is increasingly important for clinical, environmental and forensic applications. At low concentration levels (here referring to under 100 target copies DNA quantification is sensitive to losses during preparation, and suffers from appreciable valid non-detection rates for sampling reasons. This paper reports studies on a real-time quantitative PCR assay targeting a region of the human SRY gene over a concentration range of 0.5 to 1000 target copies. The effects of different sample preparation and calibration methods on quantitative accuracy were investigated. Results At very low target concentrations of 0.5–10 genome equivalents (g.e. eliminating any replicates within each DNA standard concentration with no measurable signal (non-detects compromised calibration. Improved calibration could be achieved by eliminating all calibration replicates for any calibration standard concentration with non-detects ('elimination by sample'. Test samples also showed positive bias if non-detects were removed prior to averaging; less biased results were obtained by converting to concentration, including non-detects as zero concentration, and averaging all values. Tube plastic proved to have a strongly significant effect on DNA quantitation at low levels (p = 1.8 × 10-4. At low concentrations (under 10 g.e., results for assays prepared in standard plastic were reduced by about 50% compared to the low-retention plastic. Preparation solution (carrier DNA or stabiliser was not found to have a significant effect in this study. Detection probabilities were calculated using logistic regression. Logistic regression over large concentration ranges proved sensitive to non-detected replicate reactions due to amplification failure at high concentrations; the effect could be reduced by regression against log (concentration or, better, by eliminating invalid responses

  19. Parasite load in guinea pig foetus with real time PCR after maternofoetal transmission of toxoplasma gondii

    Directory of Open Access Journals (Sweden)

    Flori P.

    2003-06-01

    Full Text Available Parasite loads of different tissues were assessed in guinea pig foetus after maternal infection. Twelve female guinea pigs were infected with 100 cysts of the 76 K strain of Toxoplasma gondii by the oral route. Inoculation was performed 20 ± 5 days (G20 or 40 ± 5 days (G40 after the beginning of gestation. Gestational age was determined by progesterone assay. Maternal and foetal organ samples were taken 60 days after the beginning of gestation. Parasite loads (from placenta, amniotic fluid (AF, cord blood (CB, foetal brain, liver, lung and spleen were assessed by a real-time PCR quantification using fluorescence resonance energy transfer (FRET hybridization probes on the Light Cycler®. Congenital transmission was proven by the presence of parasites in blood or tissue samples of the foetus in 84.6% (11/13 and 100 % (16/16 of cases after inoculation on G20 and G40 , respectively. The quantitative analysis of our results after inoculation at G20 and G40 has allowed us to determinate the positive parasitic loads as a function of the origin of the sample and the period of inoculation. The parasite loads expressed as log (parasite/g were low in AF and CB samples: 1.49 ± 0.50 and 1.05 ± 0.10 at G20 and 1.21 ± 0.36 and 1.20 ± 0.42 at G40 respectively. In contrast the placenta and the different foetal tissues had higher parasite burdens: 2.89 ± 0.54 to 5.30 ± 0.51 at G20 and 2.81 ± 0.71 to 3.65 ± 0.59 at G40 . All the placentae were positive for parasites even in the two cases with no proven transmission. Real time quantitative PCR using the hybridization probe was a very sensitive and reproducible technique to study the kinetics of congenital toxoplasmosis in the guinea pig model wich is close to that of humans.

  20. New real-time-PCR method to identify single point mutations in hepatitis C virus

    Science.gov (United States)

    Chen, Qian; Belmonte, Irene; Buti, Maria; Nieto, Leonardo; Garcia-Cehic, Damir; Gregori, Josep; Perales, Celia; Ordeig, Laura; Llorens, Meritxell; Soria, Maria Eugenia; Esteban, Rafael; Esteban, Juan Ignacio; Rodriguez-Frias, Francisco; Quer, Josep

    2016-01-01

    AIM To develop a fast, low-cost diagnostic strategy to identify single point mutations in highly variable genomes such as hepatitis C virus (HCV). METHODS In patients with HCV infection, resistance-associated amino acid substitutions within the viral quasispecies prior to therapy can confer decreased susceptibility to direct-acting antiviral agents and lead to treatment failure and virological relapse. One such naturally occurring mutation is the Q80K substitution in the HCV-NS3 protease gene, which confers resistance to PI inhibitors, particularly simeprevir. Low-cost, highly sensitive techniques enabling routine detection of these single point mutations would be useful to identify patients at a risk of treatment failure. LightCycler methods, based on real-time PCR with sequence-specific probe hybridization, have been implemented in most diagnostic laboratories. However, this technique cannot identify single point mutations in highly variable genetic environments, such as the HCV genome. To circumvent this problem, we developed a new method to homogenize all nucleotides present in a region except the point mutation of interest. RESULTS Using nucleotide-specific probes Q, K, and R substitutions at position 80 were clearly identified at a sensitivity of 10% (mutations present at a frequency of at least 10% were detected). The technique was successfully applied to identify the Q80K substitution in 240 HCV G1 serum samples, with performance comparable to that of direct Sanger sequencing, the current standard procedure for this purpose. The new method was then validated in a Catalonian population of 202 HCV G1-infected individuals. Q80K was detected in 14.6% of G1a patients and 0% of G1b in our setting. CONCLUSION A fast, low-cost diagnostic strategy based on real-time PCR and fluorescence resonance energy transfer probe melting curve analysis has been successfully developed to identify single point mutations in highly variable genomes such as hepatitis C virus. This

  1. Detection and differentiation of norovirus genogroups I and II from clinical stool specimens using real-time PCR.

    Science.gov (United States)

    Ramanan, Poornima; Espy, M J; Khare, Reeti; Binnicker, M J

    2017-04-01

    A real-time RT-PCR assay was designed to detect and differentiate norovirus genogroups I (GI) and II (GII), with primers and probes targeting the nonstructural polyprotein gene. Stool samples (n = 100) submitted for routine testing by the BioFire FilmArray® GI panel were also tested by the norovirus GI/GII real-time PCR assays. When compared to the FilmArray GI panel, the norovirus real-time PCR assay demonstrated a sensitivity of 77.5% (62/80) and specificity of 95% (19/20). Specimens yielding discordant results (n = 19) were tested at two outside laboratories for adjudication. Following discordant resolution, the adjusted sensitivity and specificity of the norovirus real-time PCR assays were 96.9% (63/65) and 100% (35/35), respectively. These results suggest that the real-time PCR assays are able to accurately detect and differentiate norovirus GI/GII from clinical stool specimens. Furthermore, our report highlights a potential issue with the specificity of the BioFire FilmArray® norovirus assay, which warrants additional investigation.

  2. Optimal swab processing recovery method for detection of bioterrorism-related Francisella tularensis by real-time PCR.

    Science.gov (United States)

    Walker, Roblena E; Petersen, Jeannine M; Stephens, Kenyatta W; Dauphin, Leslie A

    2010-10-01

    Francisella tularensis, the etiological agent of tularemia, is regarded as a potential bioterrorism agent. The advent of bioterrorism has heightened awareness of the need for validated methods for processing environmental samples. In this study we determined the optimal method for processing environmental swabs for the recovery and subsequent detection of F. tularensis by the use of real-time PCR assays. Four swab processing recovery methods were compared: heat, sonication, vortexing, and the Swab Extraction Tube System (SETS). These methods were evaluated using cotton, foam, polyester and rayon swabs spiked with six pathogenic strains of F. tularensis. Real-time PCR analysis using a multi-target 5'nuclease assay for F. tularensis showed that the use of the SETS method resulted in the best limit of detection when evaluated using multiple strains of F. tularensis. We demonstrated also that the efficiency of F. tularensis recovery from swab specimens was not equivalent for all swab processing methodologies and, thus, that this variable can affect real-time PCR assay sensitivity. The effectiveness of the SETS method was independent of the automated DNA extraction method and real-time PCR platforms used. In conclusion, diagnostic laboratories can now potentially incorporate the SETS method into specimen processing protocols for the rapid and efficient detection of F. tularensis by real-time PCR during laboratory bioterrorism-related investigations.

  3. Development of real-time PCR to detect oral vaccine-like poliovirus and its application to environmental surveillance.

    Science.gov (United States)

    Iwai-Itamochi, Masae; Yoshida, Hiromu; Obara-Nagoya, Mayumi; Horimoto, Eiji; Kurata, Takeshi; Takizawa, Takenori

    2014-01-01

    In order to perform environmental surveillance to track oral poliovirus vaccine-like poliovirus sensitively and conveniently, real-time PCR was developed and applied to a raw sewage concentrate. The real-time PCR method detected 0.01-0.1 TCID50 of 3 serotypes of Sabin strain specifically. The method also detected the corresponding serotypes of oral poliovirus vaccine-like poliovirus specifically, but detected neither wild poliovirus, except Mahoney for type 1 and Saukett for type 3, nor other enteric viruses, as far as examined. When real-time PCR was applied to environmental surveillance, the overall agreement rates between real-time PCR and the cell culture were 83.3% for all serotypes. Since real-time PCR has the advantages of rapid detection of viruses and minimum requirement of sampling volume as compared with ordinary cell culture, it is suitable to monitor oral poliovirus vaccine-like poliovirus in the environment, especially in areas where an oral vaccine is being replaced by an inactivated vaccine.

  4. Rapid, sensitive, and specific detection of Mycobacterium tuberculosis complex by real-time PCR on paraffin-embedded human tissues.

    Science.gov (United States)

    Lee, Hye Seung; Park, Kyoung Un; Park, Jung Ok; Chang, Ho Eun; Song, Junghan; Choe, Gheeyoung

    2011-07-01

    The detection of Mycobacterium tuberculosis complex (MTB) in clinical specimens is important for diagnosing and caring for patients in whom tuberculosis is clinically suspected. We collected 129 FFPE specimens, including 56 nontuberculosis cases, 63 MTB cases, and 10 nontuberculous mycobacteria (NTM) cases determined by acid-fast bacilli (AFB) culture. We performed AFB staining; nested MTB PCR, targeting the IS6110 gene; and real-time MTB PCR, targeting the senX3-regX3 intergenic region in the 129 FFPE specimens. The sensitivity and specificity of AFB staining were 37.0% and 98.2%, respectively, using AFB culture results as the reference standard. The sensitivity and specificity of detecting MTB were 68.3% and 98.5%, respectively, by nested PCR; and 74.6% and 98.5% by real-time PCR, respectively. Among the 129 specimens, four were positive by AFB staining but negative by nested or real-time PCR. NTM grew in all four of these cases by AFB culture. AFB density in FFPE tissue sections significantly correlated with MTB DNA load. Thus, real-time PCR is a useful diagnostic tool for rapid and sensitive MTB detection in FFPE specimens, whereas NTM should be included in differential diagnoses of cases positive by AFB staining but negative by PCR.

  5. Evaluation and comparison of SYBR Green I Real-Time PCR and TaqMan Real-Time PCR methods for quantitative assay of Listeria monocytogenes in nutrient broth and milk

    OpenAIRE

    Karatzas, Kimon Andreas G.

    2012-01-01

    Specific traditional plate count method and real-time PCR systems based on SYBR Green I and TaqMan technologies using a specific primer pair and probe for amplification of iap-gene were used for quantitative assay of Listeria monocytogenes in seven decimal serial dilution series of nutrient broth and milk samples containing 1.58 to 1.58×107 cfu /ml and the real-time PCR methods were compared with the plate count method with respect to accuracy and sensitivity. In this study, the plate count m...

  6. Mycoplasma detection by triplex real-time PCR in bronchoalveolar lavage fluid from bovine respiratory disease complex cases.

    Science.gov (United States)

    Cornelissen, Jan B W J; de Bree, Freddy M; van der Wal, Fimme J; Kooi, Engbert A; Koene, Miriam G J; Bossers, Alex; Smid, Bregtje; Antonis, Adriaan F; Wisselink, Henk J

    2017-04-08

    In this study we evaluated the RespoCheck Mycoplasma triplex real-time PCR for the detection in bronchoalveolar lavage fluid (BALF) of Mycoplasma (M.) dispar, M. bovis and M. bovirhinis, all three associated with bovine respiratory disease (BRD). Primers and probes of the RespoCheck Mycoplasma triplex real-time PCR are based on the V3/V4 region of the 16S rRNA gene of the three Mycoplasma species. The analytical sensitivity of the RespoCheck triplex real-time PCR was, as determined by spiking experiments of the Mycoplasma strains in Phosphate Buffered Saline, 300 colony forming units (cfu)/mL for M. dispar, and 30 cfu/mL for M. bovis or M. bovirhinis. The analytical sensitivity of the RespoCheck Mycoplasma triplex real-time PCRwas, as determined on purified DNA, 10 fg DNA per assay for M. dispar and 100 fg fo rM. bovis and M. bovirhinis. The analytical specificity of the RespoCheck Mycoplasma triplex real-time PCR was, as determined by testing Mycoplasmas strains (n = 17) and other bacterial strains (n = 107), 100, 98.2 and 99.1% for M. bovis, M. dispar and M. bovirhinis respectively. The RespoCheck Mycoplasma triplex real-time PCR was compared with the PCR/DGGE analysis for M. bovis, M. dispar and M. bovirhinis respectively by testing 44 BALF samples from calves. In conclusion, the RespoCheck PCR assay can be a valuable tool for timely and accurate detection of three Mycoplasma species associated with in bovine respiratory disease.

  7. Gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of Japanese encephalitis virus

    Science.gov (United States)

    Huang, Su-Hua; Yang, Tsuey-Ching; Tsai, Ming-Hong; Tsai, I.-Shou; Lu, Huang-Chih; Chuang, Pei-Hsin; Wan, Lei; Lin, Ying-Ju; Lai, Chih-Ho; Lin, Cheng-Wen

    2008-10-01

    Virus isolation and antibody detection are routinely used for diagnosis of Japanese encephalitis virus (JEV) infection, but the low level of transient viremia in some JE patients makes JEV isolation from clinical and surveillance samples very difficult. We describe the use of gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of JEV from its RNA genome. We tested the effect of gold nanoparticles on four different PCR systems, including conventional PCR, reverse-transcription PCR (RT-PCR), and SYBR green real-time PCR and RT-PCR assays for diagnosis in the acute phase of JEV infection. Gold nanoparticles increased the amplification yield of the PCR product and shortened the PCR time compared to the conventional reaction. In addition, nanogold-based real-time RT-PCR showed a linear relationship between Ct and template amount using ten-fold dilutions of JEV. The nanogold-based RT-PCR and real-time quantitative RT-PCR assays were able to detect low levels (1-10 000 copies) of the JEV RNA genomes extracted from culture medium or whole blood, providing early diagnostic tools for the detection of low-level viremia in the acute-phase infection. The assays described here were simple, sensitive, and rapid approaches for detection and quantitation of JEV in tissue cultured samples as well as clinical samples.

  8. Gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of Japanese encephalitis virus

    Energy Technology Data Exchange (ETDEWEB)

    Huang, S-H; Tsai, M-H; Lin, C-W [Department of Biotechnology, College of Health Science, Asia University, Wufeng, Taichung, Taiwan (China); Yang, T-C; Chuang, P-H [Department of Medical Laboratory Science and Biotechnology, China Medical University, Taichung, Taiwan (China); Tsai, I-S; Lu, H-C [Nanotechnology Research Center, Feng Chia University, Taichung, Taiwan (China); Wan Lei; Lin, Y-J [Department of Medical Genetics and Medical Research, China Medical University Hospital, Taichung, Taiwan (China); Lai, C-H [Department of Microbiology and Immunology, China Medical University, Taichung, Taiwan (China)], E-mail: cwlin@mail.cmu.edu.tw

    2008-10-08

    Virus isolation and antibody detection are routinely used for diagnosis of Japanese encephalitis virus (JEV) infection, but the low level of transient viremia in some JE patients makes JEV isolation from clinical and surveillance samples very difficult. We describe the use of gold nanoparticle-based RT-PCR and real-time quantitative RT-PCR assays for detection of JEV from its RNA genome. We tested the effect of gold nanoparticles on four different PCR systems, including conventional PCR, reverse-transcription PCR (RT-PCR), and SYBR green real-time PCR and RT-PCR assays for diagnosis in the acute phase of JEV infection. Gold nanoparticles increased the amplification yield of the PCR product and shortened the PCR time compared to the conventional reaction. In addition, nanogold-based real-time RT-PCR showed a linear relationship between Ct and template amount using ten-fold dilutions of JEV. The nanogold-based RT-PCR and real-time quantitative RT-PCR assays were able to detect low levels (1-10 000 copies) of the JEV RNA genomes extracted from culture medium or whole blood, providing early diagnostic tools for the detection of low-level viremia in the acute-phase infection. The assays described here were simple, sensitive, and rapid approaches for detection and quantitation of JEV in tissue cultured samples as well as clinical samples.

  9. Cloning and evaluation of reference genes for quantitative real-time PCR analysis in Amorphophallus

    Directory of Open Access Journals (Sweden)

    Kai Wang

    2017-04-01

    Full Text Available Quantitative real-time reverse transcription PCR (RT-qPCR has been widely used in the detection and quantification of gene expression levels because of its high accuracy, sensitivity, and reproducibility as well as its large dynamic range. However, the reliability and accuracy of RT-qPCR depends on accurate transcript normalization using stably expressed reference genes. Amorphophallus is a perennial plant with a high content of konjac glucomannan (KGM in its corm. This crop has been used as a food source and as a traditional medicine for thousands of years. Without adequate knowledge of gene expression profiles, there has been no report of validated reference genes in Amorphophallus. In this study, nine genes that are usually used as reference genes in other crops were selected as candidate reference genes. These putative sequences of these genes Amorphophallus were cloned by the use of degenerate primers. The expression stability of each gene was assessed in different tissues and under two abiotic stresses (heat and waterlogging in A. albus and A. konjac. Three distinct algorithms were used to evaluate the expression stability of the candidate reference genes. The results demonstrated that EF1-a, EIF4A, H3 and UBQ were the best reference genes under heat stress in Amorphophallus. Furthermore, EF1-a, EIF4A, TUB, and RP were the best reference genes in waterlogged conditions. By comparing different tissues from all samples, we determined that EF1-α, EIF4A, and CYP were stable in these sets. In addition, the suitability of these reference genes was confirmed by validating the expression of a gene encoding the small heat shock protein SHSP, which is related to heat stress in Amorphophallus. In sum, EF1-α and EIF4A were the two best reference genes for normalizing mRNA levels in different tissues and under various stress treatments, and we suggest using one of these genes in combination with 1 or 2 reference genes associated with different

  10. Cloning and evaluation of reference genes for quantitative real-time PCR analysis in Amorphophallus.

    Science.gov (United States)

    Wang, Kai; Niu, Yi; Wang, Qijun; Liu, Haili; Jin, Yi; Zhang, Shenglin

    2017-01-01

    Quantitative real-time reverse transcription PCR (RT-qPCR) has been widely used in the detection and quantification of gene expression levels because of its high accuracy, sensitivity, and reproducibility as well as its large dynamic range. However, the reliability and accuracy of RT-qPCR depends on accurate transcript normalization using stably expressed reference genes. Amorphophallus is a perennial plant with a high content of konjac glucomannan (KGM) in its corm. This crop has been used as a food source and as a traditional medicine for thousands of years. Without adequate knowledge of gene expression profiles, there has been no report of validated reference genes in Amorphophallus. In this study, nine genes that are usually used as reference genes in other crops were selected as candidate reference genes. These putative sequences of these genes Amorphophallus were cloned by the use of degenerate primers. The expression stability of each gene was assessed in different tissues and under two abiotic stresses (heat and waterlogging) in A. albus and A. konjac. Three distinct algorithms were used to evaluate the expression stability of the candidate reference genes. The results demonstrated that EF1-a, EIF4A, H3 and UBQ were the best reference genes under heat stress in Amorphophallus. Furthermore, EF1-a, EIF4A, TUB, and RP were the best reference genes in waterlogged conditions. By comparing different tissues from all samples, we determined that EF1-α, EIF4A, and CYP were stable in these sets. In addition, the suitability of these reference genes was confirmed by validating the expression of a gene encoding the small heat shock protein SHSP, which is related to heat stress in Amorphophallus. In sum, EF1-α and EIF4A were the two best reference genes for normalizing mRNA levels in different tissues and under various stress treatments, and we suggest using one of these genes in combination with 1 or 2 reference genes associated with different biological processes to

  11. The application of real-time PCR to the analysis of T cell repertoires.

    Science.gov (United States)

    Wettstein, Peter; Strausbauch, Michael; Therneau, Terry; Borson, Nancy

    2008-12-01

    The diversity of T-cell populations is determined by the spectrum of antigen-specific T-cell receptors (TCRs) that are heterodimers of alpha and beta subunits encoded by rearranged combinations of variable (AV and BV), joining (AJ and BJ), and constant region genes (AC and BC). We have developed a novel approach for analysis of beta transcript diversity in mice with a real-time PCR-based method that uses a matrix of BV- and BJ-specific primers to amplify 240 distinct BV-BJ combinations. Defined endpoints (Ct values) and dissociation curves are generated for each BV-BJ combination and the Ct values are consolidated in a matrix that characterizes the beta transcript diversity of each RNA sample. Relative diversities of BV-BJ combinations in individual RNA samples are further described by estimates of scaled entropy. A skin allograft system was used to demonstrate that dissection of repertoires into 240 BV-BJ combinations increases efficiency of identifying and sequencing beta transcripts that are overrepresented at inflammatory sites. These BV-BJ matrices should generate greater investigation in laboratory and clinical settings due to increased throughput, resolution and identification of overrepresented TCR transcripts.

  12. Microdroplet sandwich real-time rt-PCR for detection of pandemic and seasonal influenza subtypes.

    Directory of Open Access Journals (Sweden)

    Stephanie L Angione

    Full Text Available As demonstrated by the recent 2012/2013 flu epidemic, the continual emergence of new viral strains highlights the need for accurate medical diagnostics in multiple community settings. If rapid, robust, and sensitive diagnostics for influenza subtyping were available, it would help identify epidemics, facilitate appropriate antiviral usage, decrease inappropriate antibiotic usage, and eliminate the extra cost of unnecessary laboratory testing and treatment. Here, we describe a droplet sandwich platform that can detect influenza subtypes using real-time reverse-transcription polymerase chain reaction (rtRT-PCR. Using clinical samples collected during the 2010/11 season, we effectively differentiate between H1N1p (swine pandemic, H1N1s (seasonal, and H3N2 with an overall assay sensitivity was 96%, with 100% specificity for each subtype. Additionally, we demonstrate the ability to detect viral loads as low as 10(4 copies/mL, which is two orders of magnitude lower than viral loads in typical infected patients. This platform performs diagnostics in a miniaturized format without sacrificing any sensitivity, and can thus be easily developed into devices which are ideal for small clinics and pharmacies.

  13. Real-time immuno-PCR assay for detecting PCBs in soil samples.

    Science.gov (United States)

    Chen, Han-Yu; Zhuang, Hui-Sheng

    2009-06-01

    A fast and robust assay, based on immuno-polymerase chain reaction (IPCR) techniques, was developed for the detection of polychlorinated biphenyls (PCBs) in soil samples. Real-time IPCR (rt-IPCR) is a powerful technique that combines enzyme-linked immunosorbent assay (ELISA) with the specificity and sensitivity of PCR. In our assay, indirect ELISAs based on immobilization of PCB37 hapten-ovalbumin conjugates was used for evaluation of the immune response. The effect of optimal reagent concentrations to reduce background fluorescence was also investigated. Using the optimized assay, the linear sensitivity range of the assay covered more than six orders of magnitude, and the minimum detection limits reached 5 fg ml(-1) antigen. Rt-IPCR was tested for its cross-reactivity profiles using four selected congeners and four Aroclor products. The assays were highly specific for congeners but less specific for Aroclor1242. We took four soil samples to validate the method, and the results were confirmed by gas chromatography/mass spectrometry (GC/MS). The rt-IPCR results for soil samples correlated well with the concentrations of PCBs obtained by GC/MS (r = 0.99, n = 6). These data indicate that this highly specific, sensitive, and robust assay can be modified for detecting PCB compounds in the environment.

  14. Meloidogyne javanica Chorismate Mutase Transcript Expression Profile Using Real-Time Quantitative RT-PCR.

    Science.gov (United States)

    Painter, Janet E; Lambert, Kris N

    2003-03-01

    A developmental expression profile of the Meloidodgyne javanica esophageal gland gene chorismate mutase-1 (Mj-cm-1) could suggest when in the lifecycle of the nematode the Mj-cm-1 product is functional. This study used real-time quantitative RT-PCR to examine the variation in Mj-cm-1 transcript levels over six timepoints in the nematode lifecycle: egg, infective second-stage juveniles (Inf-J2), 2-day post-inoculation (pi), 7-day pi, 14-day pi, and adult. The Mj-cm-1 mRNA levels peaked at 2-day pi, about 100-fold above levels expressed at the egg and Inf-J2 stages. Some expression of Mj-cm-1 remained during the 7-day pi, 14-day pi, and adult stages. High transcript levels of the beta-actin control gene M. javanica Beta-actin-1 (Mj-ba-1) demonstrated the presence of cDNA at all timepoints. The peak in Mj-cm-1 transcript expression at 2-day pi as well as the previously shown esophageal gland localization of Mj-cm-1 mRNA suggest that the product of this gene may be involved early in the establishment of parasitism.

  15. Detecting Cryptosporidium parvum and Giardia lamblia by coagulation concentration and real-time PCR quantification

    Institute of Scientific and Technical Information of China (English)

    Huining ZHANG; Xiaohu Zhang; Shuting ZHANG; Bo WEI; Qipei JIANG; Xin YU

    2013-01-01

    Rapid and sensitive pathogen detection methods are essential for the effective functioning of the water treatment industry, yet for many pathogens, effective detection and removal methods are still lacking. Cryptosporidium parvum oocysts and Giardia lamblia cysts are two of the most common waterborne pathogens currently infecting the water supply. In this study, a new method was developed for the detection of Cryptosporidium parvum oocysts and Giardia lamblia cysts. The method includes multi-steps as coagulation concentration of (oo)cysts in water, the dissolution of the resulting flocs into a small volume using acid, filtration of the (oo)cysts solution, and DNA extraction, purification, and examination using real-time PCR. The method was tested using spiked tap water and reservoir water as references, and the mean recovery ranged from 19.6% to 97.6% for oocysts, and from 51.4% to 98.7% for cysts. The method is economical and convenient, and is especially suitable for relatively high turbidity surface water.

  16. Microscopy, culture, and quantitative real-time PCR examination confirm internalization of mycobacteria in plants.

    Science.gov (United States)

    Kaevska, M; Lvoncik, S; Slana, I; Kulich, P; Kralik, P

    2014-07-01

    The environment is a reservoir of nontuberculous mycobacteria and is considered a source of infection for animals and humans. Mycobacteria can persist in different types of environments for a relatively long time. We have studied their possible internalization into plant tissue through intact, as well as damaged, root systems of different types of plants grown in vitro and under field conditions. The substrate into which plants were seeded was previously contaminated with different strains of Mycobacterium avium (10(8) to 10(10) cells/g of soil) and feces from animals with paratuberculosis. We detected M. avium subsp. avium, hominissuis, and paratuberculosis in the stems and leaves of the plants by both culture and real-time quantitative PCR. The presence of mycobacteria in the plant tissues was confirmed by microscopy. The concentration of mycobacteria found inside plant tissue was several orders of magnitude lower (up to 10(4) cells/g of tissue) than the initial concentration of mycobacteria present in the culture medium or substrate. These findings led us to the hypothesis that plants may play a role in the spread and transmission of mycobacteria to other organisms in the environment.

  17. Fast Real-Time PCR for the Detection of Crustacean Allergens in Foods.

    Science.gov (United States)

    Santaclara, Francisco J; Espiñeira, Montserrat

    2017-01-01

    Crustaceans are one of the most common allergens causing severe food reaction. Hypersensitivity reactions associated with seafood intake are one of the most common food allergies in adults. Crustaceans including shrimps, prawns, crabs, lobster, and crayfish are a common cause of anaphylaxis or hypersensitivity, with shrimps and crabs being the most common causes of allergy. Symptoms occur most often when food or cooking water are ingested.These food allergens are a health problem, and they have become very important; as evidenced by the existence of several regulations that establish that labeling must be present regarding these allergens to warn consumers.The methodology herein exposed allows the detection of crustaceans in any type of product, including those where very aggressive treatments of temperature and pressure are used during the manufacturing process.The main features of this method are its high sensitivity and specificity, and reduced analysis time of real-time PCR (40 min). This assay is a potential tool in issues related to the labeling of products and food security to protect the allergic consumer.

  18. Reference gene selection for quantitative real-time PCR normalization in Reaumuria soongorica.

    Science.gov (United States)

    Yan, Xia; Dong, Xicun; Zhang, Wen; Yin, Hengxia; Xiao, Honglang; Chen, Peng; Ma, Xiao-Fei

    2014-01-01

    Despite its superiority for evaluating gene expression, real-time quantitative polymerase chain reaction (qPCR) results can be significantly biased by the use of inappropriate reference genes under different experimental conditions. Reaumuria soongorica is a dominant species of desert ecosystems in arid central Asia. Given the increasing interest in ecological engineering and potential genetic resources for arid agronomy, it is important to analyze gene function. However, systematic evaluation of stable reference genes should be performed prior to such analyses. In this study, the stabilities of 10 candidate reference genes were analyzed under 4 kinds of abiotic stresses (drought, salt, dark, and heat) within 4 accessions (HG010, HG020, XGG030, and XGG040) from 2 different habitats using 3 algorithms (geNorm, NormFinder, and BestKeeper). After validation of the ribulose-1,5-bisphosphate carboxylase/oxygenase large unite (rbcL) expression pattern, our data suggested that histone H2A (H2A) and eukaryotic initiation factor 4A-2 (EIF4A2) were the most stable reference genes, cyclophilin (CYCL) was moderate, and elongation factor 1α (EF1α) was the worst choice. This first systematic analysis for stably expressed genes will facilitate future functional analyses and deep mining of genetic resources in R. soongorica and other species of the Reaumuria genus.

  19. Detection of Salmonella spp. in veterinary samples by combining selective enrichment and real-time PCR.

    Science.gov (United States)

    Goodman, Laura B; McDonough, Patrick L; Anderson, Renee R; Franklin-Guild, Rebecca J; Ryan, James R; Perkins, Gillian A; Thachil, Anil J; Glaser, Amy L; Thompson, Belinda S

    2017-08-01

    Rapid screening for enteric bacterial pathogens in clinical environments is essential for biosecurity. Salmonella found in veterinary hospitals, particularly Salmonella enterica serovar Dublin, can pose unique challenges for culture and testing because of its poor growth. Multiple Salmonella serovars including Dublin are emerging threats to public health given increasing prevalence and antimicrobial resistance. We adapted an automated food testing method to veterinary samples and evaluated the performance of the method in a variety of matrices including environmental samples ( n = 81), tissues ( n = 52), feces ( n = 148), and feed ( n = 29). A commercial kit was chosen as the basis for this approach in view of extensive performance characterizations published by multiple independent organizations. A workflow was established for efficiently and accurately testing veterinary matrices and environmental samples by use of real-time PCR after selective enrichment in Rappaport-Vassiliadis soya (RVS) medium. Using this method, the detection limit for S. Dublin improved by 100-fold over subculture on selective agars (eosin-methylene blue, brilliant green, and xylose-lysine-deoxycholate). Overall, the procedure was effective in detecting Salmonella spp. and provided next-day results.

  20. Real-time PCR quantification of gene expression in embryonic mouse tissue.

    Science.gov (United States)

    Villalon, Eric; Schulz, David J; Waters, Samuel T

    2014-01-01

    The Gbx family of transcription factors consists of two closely related proteins GBX1 and GBX2. A defining feature of the GBX family is a highly conserved 60 amino acid DNA-binding domain, which differs by just two amino acids. Gbx1 and Gbx2 are co-expressed in several areas of the developing central nervous system including the forebrain, anterior hindbrain, and spinal cord, suggesting the potential for genetic redundancy. However, there is a spatiotemporal difference in expression of Gbx1 and Gbx2 in the forebrain and spinal cord. Gbx2 has been shown to play a critical role in positioning the midbrain/hindbrain boundary and developing anterior hindbrain, whereas gene-targeting experiments in mice have revealed an essential function for Gbx1 in the spinal cord for normal locomotion. To determine if Gbx2 could potentially compensate for a loss of Gbx1 in the developing spinal cord, we performed real-time PCR to examine levels of Gbx2 expression in Gbx1(-/-) spinal cord at embryonic day (E) 13.5, a developmental stage when Gbx2 is rapidly downregulated. We demonstrate that Gbx2 expression is elevated in the spinal cord of Gbx1(-/-) embryos.

  1. Dynamics of microcystin production and quantification of potentially toxigenic Microcystis sp. using real-time PCR.

    Science.gov (United States)

    Srivastava, Ankita; Choi, Gang-Guk; Ahn, Chi-Yong; Oh, Hee-Mock; Ravi, Alok Kumar; Asthana, Ravi Kumar

    2012-03-01

    Cyanobacterial blooms in eutrophied water body are generally composed of various genotypes with or without microcystin-producing genes (mcy gene cluster). Thus there is a need for quantification of potent toxin producing strains. The present study aimed at identifying microcystin variants and its producer strains in Durgakund pond, Varanasi, India, based on quantification of cpcBA-IGS and mcyA (condensation domain) genes using real-time PCR and LC-MS. Increase in microcystin concentrations was correlated with increase in mcyA copy number and the level of pigments (chlorophyll a, phycocyanin and carotenoids). Also, selected environmental factors (water temperature, light irradiance, rainfall, pH, N and P) and the concentration of microcystin variants (MC-LR, -RR and -YR) were also assessed in samples during May 2010 to April 2011 to establish the possible correlation among these parameters. Nutrients favored cyanobacterial bloom but it could not be correlated with the levels of microcystin variants and seemed to be geographically specific. Microcystis sp. dominant in the pond comprised potentially toxigenic cells. The ratio of potentially toxigenic Microcystis sp. to that of total Microcystis sp. ranged from 0% to 14%. Such studies paved the way to identify and quantify the most potent microcystin producer in the tropical aquatic body.

  2. A new real-time PCR for the detection of Plasmodium ovale wallikeri.

    Directory of Open Access Journals (Sweden)

    Adriana Calderaro

    Full Text Available It has been proposed that ovale malaria in humans is caused by two closely related but distinct species of malaria parasites: P. ovale curtisi and P. ovale wallikeri. We have extended and optimized a Real-time PCR assay targeting the parasite's small subunit ribosomal RNA (ssrRNA gene to detect both these species. When the assay was applied to 31 archival blood samples from patients diagnosed with P. ovale, it was found that the infection in 20 was due to P. ovale curtisi and in the remaining 11 to P. ovale wallikeri. Thus, this assay provides a useful tool that can be applied to epidemiological investigations of the two newly recognized distinct P. ovale species, that might reveal if these species also differ in their clinical manifestation, drugs susceptibility and relapse periodicity. The results presented confirm that P. ovale wallikeri is not confined to Southeast Asia, since the majority of the patients analyzed in this study had acquired their P. ovale infection in African countries, mostly situated in West Africa.

  3. Salmonella spp. fecal shedding detected by real-time PCR in competing endurance horses.

    Science.gov (United States)

    Fielding, C Langdon; Meier, Chloe A; Magdesian, K Gary; Pusterla, Nicola

    2013-09-01

    Fecal shedding of Salmonella spp. was recently documented in 8% of endurance horses presented to equine referral centers for colic. Previous studies have documented fecal shedding of Salmonella spp. in as few as 0.8% of the general horse population, although horses with colic appear to be at higher risk. Fecal Salmonella spp. shedding before and after endurance horse competitions has not been evaluated. Fecal samples were collected from 204 horses during three separate 100 mile endurance competitions. Following incubation in selenite broth, 289 fecal samples were tested by real-time PCR analysis for Salmonella spp. Only one post-race sample (0.5% tested positive for Salmonella spp. in this study and no pre-race sample was available from this horse. Results suggest that fecal shedding of Salmonella spp. is uncommon in endurance horses during competitions. Further research is needed to confirm and identify the source of Salmonella spp. infection in endurance horses with colic requiring treatment at referral centers.

  4. Expression patterns of Doppel gene in golden hamster: quantification using real-time RT-PCR.

    Science.gov (United States)

    Li, Y R; Li, Q; Yang, J M; Zhou, X M; Yin, X M; Zhao, D M

    2008-08-01

    Doppel (prion-like protein, Dpl) may act as a useful molecular marker in tumor diagnosis and in tumor grade definition, as over-expression of Dpl protein has been found in tumors with different histologic origin. Accordingly, the quantitative analysis of the expression of Dpl in different tissues is essential for understanding its role in tumor progression and cancer diagnostic. Herein we report Dpl mRNA quantification in golden hamster by calibrated highly sensitive externally standardized real-time RT-PCR with LightCycler instrument. Total RNA was isolated from nine different organs of golden hamster in different stages of development: from neonatal to adult golden hamster. Highest level of Dpl mRNA was detected in the testis, and lower levels of Dpl mRNA were detected in the following tissues: spleen, heart, bone marrow, skeletal muscles and neocortex (only in neonatal hamster). The expression of Dpl was not detected in kidney, liver and lung. This is the first study to report the expression of Dpl in bone marrow of murine and the difference of expression levels of Dpl in testis between adult and neonatal hamsters.

  5. Studying the replication history of human B lymphocytes by real-time quantitative (RQ)-PCR.

    Science.gov (United States)

    van Zelm, Menno C; Berkowska, Magdalena A; van Dongen, Jacques J M

    2013-01-01

    The cells of the adaptive immune system, B and T lymphocytes, each generate a unique antigen receptor through V(D)J recombination of their immunoglobulin (Ig) and T cell receptor (TCR) loci, respectively. Such rearrangements join coding elements to form a coding joint and delete the intervening DNA as circular excision products containing the signal joint. These excision circles are stable structures that cannot replicate and have no function in the cell. Since the coding joint in the genome is replicated with each cell division, the ratio between coding joints and signal joints in a population of B cells can be used as a measure for proliferation. This chapter describes a real-time quantitative (RQ-)PCR-based approach to quantify proliferation through calculating the ratio between coding joints and signal joints of the frequently occurring intronRSS-Kde rearrangements in the IGK light chain locus. The approach is useful to study basic B-cell biology as well as abnormal proliferation in human diseases.

  6. A novel method for diagnosis of smear-negative tuberculosis patients by combining a random unbiased Phi29 amplification with a specific real-time PCR.

    Science.gov (United States)

    Pang, Yu; Lu, Jie; Yang, Jian; Wang, Yufeng; Cohen, Chad; Ni, Xin; Zhao, Yanlin

    2015-07-01

    In this study, we develop a novel method for diagnosis of smear-negative tuberculosis patients by performing a random unbiased Phi29 amplification prior to the use of a specific real-time PCR. The limit of detection (LOD) of the conventional real-time PCR was 100 colony-forming units (CFU) of MTB genome/reaction, while the REPLI real-time PCR assay could detect 0.4 CFU/reaction. In comparison with the conventional real-time PCR, REPLI real-time PCR shows better sensitivity for the detection of smear-negative tuberculosis (P = 0.015).

  7. Detection of Bartonella spp. in wild rodents in Israel using HRM real-time PCR.

    Science.gov (United States)

    Morick, Danny; Baneth, Gad; Avidor, Boaz; Kosoy, Michael Y; Mumcuoglu, Kosta Y; Mintz, Dvir; Eyal, Osnat; Goethe, Ralph; Mietze, Andreas; Shpigel, Nahum; Harrus, Shimon

    2009-11-18

    The prevalence of Bartonella spp. in wild rodents was studied in 19 geographical locations in Israel. One hundred and twelve rodents belonging to five species (Mus musculus, Rattus rattus, Microtus socialis, Acomys cahirinus and Apodemus sylvaticus) were included in the survey. In addition, 156 ectoparasites were collected from the rodents. Spleen sample from each rodent and the ectoparasites were examined for the presence of Bartonella DNA using high resolution melt (HRM) real-time PCR. The method was designed for the simultaneous detection and differentiation of eight Bartonella spp. according to the nucleotide variation in each of two gene fragments (rpoB and gltA) and the 16S-23S intergenic spacer (ITS) locus, using the same PCR protocol which allowed the simultaneous amplification of the three different loci. Bartonella DNA was detected in spleen samples of 19 out of 79 (24%) black rats (R. rattus) and in 1 of 4 (25%) Cairo spiny mice (A. cahirinus). In addition, 15 of 34 (44%) flea pools harbored Bartonella DNA. Only rat flea (Xenopsyla cheopis) pools collected from black rats (R. rattus) were positive for Bartonella DNA. The Bartonella sp. detected in spleen samples from black rats (R. rattus) was closely related to both B. tribocorum and B. elizabethae. The species detected in the Cairo spiny mouse (A. cahirinus) spleen sample was closely related to the zoonotic pathogen, B. elizabethae. These results indicate that Bartonella species are highly prevalent in suburban rodent populations and their ectoparasites in Israel. Further investigation of the prevalence and zoonotic potential of the Bartonella species detected in the black rats and the Cairo spiny mouse is warranted.

  8. Rapid qualitative urinary tract infection pathogen identification by SeptiFast real-time PCR.

    Directory of Open Access Journals (Sweden)

    Lutz E Lehmann

    Full Text Available BACKGROUND: Urinary tract infections (UTI are frequent in outpatients. Fast pathogen identification is mandatory for shortening the time of discomfort and preventing serious complications. Urine culture needs up to 48 hours until pathogen identification. Consequently, the initial antibiotic regimen is empirical. AIM: To evaluate the feasibility of qualitative urine pathogen identification by a commercially available real-time PCR blood pathogen test (SeptiFast® and to compare the results with dipslide and microbiological culture. DESIGN OF STUDY: Pilot study with prospectively collected urine samples. SETTING: University hospital. METHODS: 82 prospectively collected urine samples from 81 patients with suspected UTI were included. Dipslide urine culture was followed by microbiological pathogen identification in dipslide positive samples. In parallel, qualitative DNA based pathogen identification (SeptiFast® was performed in all samples. RESULTS: 61 samples were SeptiFast® positive, whereas 67 samples were dipslide culture positive. The inter-methodological concordance of positive and negative findings in the gram+, gram- and fungi sector was 371/410 (90%, 477/492 (97% and 238/246 (97%, respectively. Sensitivity and specificity of the SeptiFast® test for the detection of an infection was 0.82 and 0.60, respectively. SeptiFast® pathogen identifications were available at least 43 hours prior to culture results. CONCLUSION: The SeptiFast® platform identified bacterial DNA in urine specimens considerably faster compared to conventional culture. For UTI diagnosis sensitivity and specificity is limited by its present qualitative setup which does not allow pathogen quantification. Future quantitative assays may hold promise for PCR based UTI pathogen identification as a supplementation of conventional culture methods.

  9. Estimating the number of integrations in transformed plants by quantitative real-time PCR

    Directory of Open Access Journals (Sweden)

    Vaira Anna Maria

    2002-10-01

    Full Text Available Abstract Background When generating transformed plants, a first step in their characterization is to obtain, for each new line, an estimate of how many copies of the transgene have been integrated in the plant genome because this can deeply influence the level of transgene expression and the ease of stabilizing expression in following generations. This task is normally achieved by Southern analysis, a procedure that requires relatively large amounts of plant material and is both costly and labour-intensive. Moreover, in the presence of rearranged copies the estimates are not correct. New approaches to the problem could be of great help for plant biotechnologists. Results By using a quantitative real-time PCR method that requires limited preliminary optimisation steps, we achieved statistically significant estimates of 1, 2 and 3 copies of a transgene in the primary transformants. Furthermore, by estimating the copy number of both the gene of interest and the selectable marker gene, we show that rearrangements of the T-DNA are not the exception, and probably happen more often than usually recognised. Conclusions We have developed a rapid and reliable method to estimate the number of integrated copies following genetic transformation. Unlike other similar procedures, this method is not dependent on identical amplification efficiency between the PCR systems used and does not need preliminary information on a calibrator. Its flexibility makes it appropriate in those situations where an accurate optimisation of all reaction components is impossible or impractical. Finally, the quality of the information produced is higher than what can be obtained by Southern blot analysis.

  10. Exploring valid reference genes for gene expression studies in Brachypodium distachyon by real-time PCR

    Directory of Open Access Journals (Sweden)

    Xiang Fengning

    2008-11-01

    Full Text Available Abstract Background The wild grass species Brachypodium distachyon (Brachypodium hereafter is emerging as a new model system for grass crop genomics research and biofuel grass biology. A draft nuclear genome sequence is expected to be publicly available in the near future; an explosion of gene expression studies will undoubtedly follow. Therefore, stable reference genes are necessary to normalize the gene expression data. Results A systematic exploration of suitable reference genes in Brachypodium is presented here. Nine reference gene candidates were chosen, and their gene sequences were obtained from the Brachypodium expressed sequence tag (EST databases. Their expression levels were examined by quantitative real-time PCR (qRT-PCR using 21 different Brachypodium plant samples, including those from different plant tissues and grown under various growth conditions. Effects of plant growth hormones were also visualized in the assays. The expression stability of the candidate genes was evaluated using two analysis software packages, geNorm and NormFinder. In conclusion, the ubiquitin-conjugating enzyme 18 gene (UBC18 was validated as a suitable reference gene across all the plant samples examined. While the expression of the polyubiquitin genes (Ubi4 and Ubi10 was most stable in different plant tissues and growth hormone-treated plant samples, the expression of the S-adenosylmethionine decarboxylase gene (SamDC ranked was most stable in plants grown under various environmental stresses. Conclusion This study identified the reference genes that are most suitable for normalizing the gene expression data in Brachypodium. These reference genes will be particularly useful when stress-responsive genes are analyzed in order to produce transgenic plants that exhibit enhanced stress resistance.

  11. Confirmation of the spinal motor neuron gene 2 (SMN2) copy numbers by real-time PCR.

    Science.gov (United States)

    Wieme, Maamouri-Hicheri; Monia Ben, Hammer; Yosr, Bouhlal; Sihem, Souilem; Nawel, Toumi; Ines, Manai-Azizi; Wajdi, Bennour; Najla, Khmiri; Houda, Nahdi; Faycal, Hentati; Rim, Amouri

    2012-09-01

    Spinal muscular atrophy (SMA) is an autosomal recessive disease caused by mutation or deletion of the survival motor neuron gene 1 (SMN1). SMN2, a copy gene, influences the severity of SMA and may be used in somatic gene therapy of patients with SMA in the future. The SMA carrier analysis developed at the Institute of Medical Genetics, Catholic University (Rome), on the Applied Biosystems real-time PCR instruments by Dr Danilo Tiziano and his group, provides a robust workflow to evaluate SMA carrier status. In this study, the SMN2 copy number was confirmed on 22 patients by developing our own assay on the basis of a relative real-time PCR system using the 7500 Fast Real-Time PCR System.

  12. Development of a real-time PCR method to detect potentially allergenic sesame (Sesamum indicum) in food.

    Science.gov (United States)

    Schöringhumer, Kerstin; Cichna-Markl, Margit

    2007-12-26

    Recent papers indicate that the prevalence of allergic reactions to sesame (Sesamum indicum) is increasing in European countries. This paper describes the development of a selective real-time PCR method for the detection of sesame in food. The assay did not show any cross-reactivity with 17 common food ingredients. The real-time PCR method was applied to determine sesame in several crackers, salty snacks, biscuits, tahina sesame paste and sesame oil. With the exception of sesame oil, in all of the samples where sesame was declared, sesame was detected by the real-time PCR assay (Ct valuesesame or where sesame was not listed, sesame could not be detected (Ct value>35).

  13. Diagnosis of ocular toxoplasmosis by two polymerase chain reaction (PCR) examinations: qualitative multiplex and quantitative real-time.

    Science.gov (United States)

    Sugita, Sunao; Ogawa, Manabu; Inoue, Shizu; Shimizu, Norio; Mochizuki, Manabu

    2011-09-01

    To establish a two-step polymerase chain reaction (PCR) diagnostic system for ocular toxoplasmosis. A total of 13 ocular fluid samples (11 aqueous humor and 2 vitreous fluid) were collected from 13 patients with clinically suspected ocular toxoplasmosis. Ten ocular samples from other uveitis patients and 20 samples from subjects without ocular inflammation were used as controls. Two polymerase chain reaction (PCR) methods, i.e., qualitative multiplex PCR and quantitative real-time PCR, were used to measure the toxoplasma genome (T. gondii B1 gene). Qualitative multiplex PCR detected T. gondii B1 gene in the ocular fluids of 11 out of 13 patients with clinically suspected ocular toxoplasmosis. In real-time PCR, we detected high copy numbers of T. gondii DNA (5.1 × 10(2)-2.1 × 10(6) copies/mL) in a total of 10 patients (10/13, 77%). Only ocular toxoplasmosis scar lesions were observed in the three real-time PCR-negative patients. PCR assay results for the samples from the two control groups were all negative. The two-step PCR examination to detect toxoplasma DNA is a useful tool for diagnosing ocular toxoplasmosis.

  14. Using Quantitative Real-Time PCR to Detect MicroRNA Expression Profile During Embryonic Stem Cell Differentiation.

    Science.gov (United States)

    Pan, Xiaoping; Murashov, Alexander K; Stellwag, Edmund J; Zhang, Baohong

    2017-01-01

    Quantitative real-time PCR (qRT-PCR) is a reliable method to determine and monitor microRNA (miRNA) expression profiles in different cells, tissues, and organisms. Although there are several different strategies in performing qRT-PCR to determine miRNA expression, all of them have two steps in common: reverse transcription for obtaining cDNA from mature miRNA sequencing and standard real-time PCR for amplification of cDNA. This chapter demonstrates the application of quantitative real-time PCR for determining miRNA expression profiles during mouse embryonic stem cell differentiation. In this method, a mature miRNA sequence is first reverse transcribed into a long cDNA with a 40-50 nt miRNA-specific stem-loop primer; then, a standard real-time PCR reaction is performed for determining miRNA expression using a forward miRNA-specific primer and a universal reverse primer.

  15. Application of a real-time PCR method for detecting and monitoring hookworm Necator americanus infections in Southern China

    Institute of Scientific and Technical Information of China (English)

    Jia-Xu Wang; Cang-Sang Pan; Li-Wang Cui

    2012-01-01

    Objective: To develop a quantitative PCR method for detecting hookworm infection and quantification. Methods:A real-time PCR method was designed based on the intergenic region II of ribosomal DNA of the hookworm Necator americanus. The detection limit of this method was compared with the microscopy-based Kato-Katz method. The real-time PCR method was used to conduct an epidemiological survey of hookworm infection in southern Fujian Province of China. Results:The real-time PCR method was specific for detecting Necator americanus infection, and was more sensitive than conventional PCR or microscopy-based method. A preliminary survey for hookworm infection in villages of Fujian Province confirmed the high prevalence of hookworm infections in the resident populations. In addition, the infection rate in women was significantly higher than that of in men. Conclusions: A real-time PCR method is designed, which has increased detection sensitivity for more accurate epidemiological studies of hookworm infections, especially when intensity of the infection needs to be considered.

  16. Development of a real-time PCR method (Taqman) for rapid identification and quantification of Prorocentrum donghaiense

    Science.gov (United States)

    Yuan, Jian; Mi, Tiezhu; Zhen, Yu; Yu, Zhigang

    2012-09-01

    Prorocentrum donghaiense is a dinoflagellate that is widely distributed in the East China Sea and has become increasingly involved in Harmful Algal Blooms (HABs). Therefore, it is necessary to study this dinoflagellate to monitor HABs. In this study, 13 pairs of primers specific to P. donghaiense (within its internal transcribed spacer (ITS) regions) were designed for SYBR Green I real-time PCR. As the SYBR Green I real-time PCR could not identify P. donghaiense in a specific manner, a Taqman real-time PCR method was developed by designing a set of specific primers and a Taqman probe. A 10-fold serial dilution of recombinant plasmid containing ITS regions of P. donghaiense was prepared as standard samples and the standard curve was established. Additionally, we quantified the genomic DNA in P. donghaiense cells and utilized this DNA to prepare another 10-fold serial dilution of standard sample and accordingly set up the standard curve. The mathematic correlation between the cell number and its corresponding plasmid copy number was also established. In order to test the efficiency of the real-time PCR method, laboratory samples and P. donghaiense HAB field samples were employed for identification and quantitative analysis. As to laboratory samples, as few as 102 cells of P. donghaiense could be quantified precisely utilizing both centrifugation and filtration techniques. The quantification results from field samples by real-time PCR were highly similar to those by light microscopy. In conclusion, the real-time PCR could be applied to identify and quantify P. donghaiense in HABs.

  17. Diagnosis of viral gastroenteritis in children: interpretation of real-time PCR results and relation to clinical symptoms.

    Science.gov (United States)

    Corcoran, M S; van Well, G T J; van Loo, I H M

    2014-10-01

    Molecular methods such as real-time polymerase chain reaction (PCR) are rapidly replacing traditional tests to detect fecal viral pathogens in childhood diarrhea. This technique has now increased the analytical sensitivity so drastically that positive results are found in asymptomatic children, leading to complex interpretation of real-time PCR results and difficult distinction between asymptomatic shedding and etiological cause of disease. We performed a review of the literature including pediatric studies using real-time PCR and a minimal inclusion period of one year to exclude bias by seasonality. We searched for studies on rotavirus, norovirus, adenovirus, astrovirus, and sapovirus, known to be the most common viruses to cause gastroenteritis in the pediatric population. For these viruses, we summarized the detection rates in hospitalized and community-based children with clinical symptoms of gastroenteritis, as well as subjects with asymptomatic viral shedding. Moreover, insight is given into the different viral sero- and genotypes causing pediatric gastroenteritis. We also discuss the scoring systems for severity of disease and their clinical value. A few published proposals have been made to improve the clinical interpretation of real-time PCR results, which we recapitulate and discuss in this review. We propose using the semi-quantitative measure of real-time PCR, as a surrogate for viral load, in relation to the severity score to distinguish asymptomatic viral shedding from clinically relevant disease. Overall, this review provides a better understanding of the scope of childhood gastroenteritis, discusses a method to enhance the interpretation of real-time PCR results, and proposes conditions for future research to enhance clinical implementation.

  18. Development of a Real-Time PCR Method (Taqman) for Rapid Identification and Quantification of Prorocentrum donghaiense

    Institute of Scientific and Technical Information of China (English)

    YUAN Jian; MI Tiezhu; ZHEN Yu; YU Zhigang

    2012-01-01

    Prorocentrum donghaiense is a dinoflagellate that is widely distributed in the East China Sea and has become increasingly involved in Harmful Algal Blooms(HABs).Therefore,it is necessary to study this dinoflagellate to monitor HABs.In this study,13 pairs of primers specific to P.donghaiense(within its internal transcribed spacer(ITS)regions)were designed for SYBR Green Ⅰ real-time PCR.As the SYBR Green Ⅰ real-time PCR could not identify P donghaiense in a specific manner,a Taqman real-time PCR method was developed by designing a set of specific primers and a Taqman probe.A 10-fold serial dilution of recombinant plasmid containing ITS regions of P.donghaiense was prepared as standard samples and the standard curve was established.Additionally,we quantified the genomic DNA in P.donghaiense cells and utilized this DNA to prepare another 10-fold serial dilution of standard sample and accordingly set up the standard curve.The mathematic correlation between the cell number and its corresponding plasmid copy number was also established.In order to test the efficiency of the real-time PCR method,laboratory samples and P.donghaiense HAB field samples were employed for identification and quantitative analysis.As to laboratory samples,as few as 102 cells of P.donghaiense could be quantified precisely utilizing both centrifugation and filtration techniques.The quantification results from field samples by real-time PCR were highly similar to those by light microscopy.In conclusion,the real-time PCR could be applied to identify and quantify P.donghaiense in HABs.

  19. Assessment of HER-2 gene overexpression in Isfahan province breast cancer patients using Real Time RT-PCR and immunohistochemistry.

    Science.gov (United States)

    Tabatabaeian, Hosein; Hojati, Zohreh

    2013-11-15

    Overexpression of proto-oncogene HER-2 is one of the main molecular markers of breast cancer involved in prognosis and diagnosis and also in trastuzumab therapy. Thus, a request for the evaluation of HER-2 status in breast cancer has been increasing. The aim of our study was assessment of HER-2 overexpression in malignant and benign breast cancer specimens by Real Time RT-PCR technique and comparison of its results with IHC outcomes. Twenty benign and sixty malignant breast cancers in addition to fifteen normal breast tissue specimens were analyzed by Real Time RT-PCR method. Fresh tissue samples were disrupted by mortar and pestle. A syringe and a needle were used for complete homogenization of the tissues. The RNA was then isolated from the samples and converted to cDNA. A standard curve was initially plotted using BioEasy SYBR Green I and then all 95 specimens were studied by Real Time RT-PCR using 2(-ΔΔCt) method. 23.3% of 60 malignant specimens showed HER-2 overexpression, while all of the benign samples represented the normal expression level of HER-2 gene. The concordance rate between the results of Real Time RT-PCR and IHC was 86.6%. Real Time RT-PCR method is an almost reliable technique and at least can be used as a complementary method for confirming IHC results. This is emanated from relatively high rate of concordance between outcomes of IHC test, as a routine method of detecting the HER-2 gene expression status, and Real Time RT-PCR technique. © 2013 Elsevier B.V. All rights reserved.

  20. A meta-analysis to evaluate the effectiveness of real-time PCR for diagnosing novel coronavirus infections.

    Science.gov (United States)

    Lin, C; Ye, R; Xia, Y L

    2015-12-02

    Novel coronavirus (nCoV) belongs to the Coronaviridae family, which includes the virus that causes SARS, or severe acute respiratory syndrome. However, infection source, transmission route, and host of nCoV have not yet been thoroughly characterized. In some cases, nCoV presented a limited person-to-person transmission. Therefore, early diagnosis of nCoV may be of importance for reducing the spread of disease in public. Methods for nCoV diagnosis involve smear dyeing inspection, culture identification, and real-time PCR detection, all of which are proved highly effective. Here, we performed a meta-analysis to evaluate the effectiveness of real-time PCR for diagnosing nCoV infection. Fifteen articles conformed to the inclusion and exclusion criteria for further meta-analysis on the basis of a wide range of publications searched from databases involving PubMed, EMBASE, Web of Science, Medline, ISI. We analyzed the stability and publication bias as well as examined the heterogeneity inspection of real-time PCR detection in contrast to smear staining and culture identification. The fixed-effect model was adopted in our meta-analysis. Our result demonstrated that the combination of real-time PCR and smear diagnostics yielded an odds ratio (OR) = 1.91, 95% confidence interval (CI) = 1.51-2.41, Z = 5.43, P real-time PCR and culture identification yielded OR = 2.44, 95%CI = 1.77-3.37, Z = 5.41, P real-time PCR as an efficient method that offers an auxiliary support for future nCoV diagnosis.

  1. Development of a real-time SYBR Green PCR assay for the rapid detection of Dermatophilus congolensis.

    Science.gov (United States)

    García, Alfredo; Martínez, Remigio; Benitez-Medina, José Manuel; Risco, David; Garcia, Waldo Luis; Rey, Joaquín; Alonso, Juan Manuel; Hermoso de Mendoza, Javier

    2013-01-01

    Methods such as real time (RT)-PCR have not been developed for the rapid detection and diagnosis of Dermatophilus (D.) congolensis infection. In the present study, a D. congolensis-specific SYBR Green RT-PCR assay was evaluated. The detection limit of the RT-PCR assay was 1 pg of DNA per PCR reaction. No cross-reaction with nucleic acids extracted from Pseudomonas aeruginosa, Mycobacterium tuberculosis, Staphylococcus aureus, or Austwickia chelonae was observed. Finally, the RT-PCR assay was used to evaluate clinical samples collected from naturally infected animals with D. congolensis. The results showed that this assay is a fast and reliable method for diagnosing dermatophilosis.

  2. The gut microbiotassay – a high-throughput real-time PCR chip combined with next generation sequencing

    DEFF Research Database (Denmark)

    Hermann-Bank, Marie Louise; Skovgaard, Kerstin; Mølbak, Lars

    this assay with the high-throughput real-time PCR chip “Access Array 48.48” from Fluidigm. The chip executes 2304 individual reactions in parallel and afterwards it is possible to harvest the amplicons for next-generation sequencing. This approach gives a taxonomical overview of the gut microbiota, hence...... generation sequencing both provides a quantitative measure in terms of Cq-values achieved from the real-time PCR, as well as the deeper information obtained from next-generation sequencing of the amplicons. It is quick to perform and offers a high-throughput at a relatively low cost. These features make...

  3. Real time PCR detection of rabbit haemorrhagic disease virus in rabbits infected with different European strains of RHDV.

    Science.gov (United States)

    Niedźwiedzka-Rystwej, P; Hukowska-Szematowicz, B; Działo, J; Tokarz-Deptuła, B; Deptuła, W

    2013-01-01

    The paper concerns the use of a novel, very effective diagnostic method, a real-time PCR for diagnosis of a viral agent causing viral haemorrhagic disease in rabbits - RHDV. Until now, the method was widely used for detecting many different viruses, both DNA, and RNA, but as far as RHDV is concerned, there are not many records of such use. This study aimed at the detection of 17 different strains from different European regions, differing in biological features and mortality. The study confirmed that real-time PCR is an applicable and effective method for diagnosis of RHDV, irrespective of the stains' features.

  4. Multiplex Real-Time PCR Assay for Rapid Detection of Methicillin-Resistant Staphylococci Directly from Positive Blood Cultures

    OpenAIRE

    Wang, Hye-young; Kim, Sunghyun; Kim, Jungho; Park, Soon-Deok; Uh, Young; Lee, Hyeyoung

    2014-01-01

    Methicillin-resistant Staphylococcus aureus (MRSA) is the most prevalent cause of bloodstream infections (BSIs) and is recognized as a major nosocomial pathogen. This study aimed to evaluate a newly designed multiplex real-time PCR assay capable of the simultaneous detection of mecA, S. aureus, and coagulase-negative staphylococci (CoNS) in blood culture specimens. The Real-MRSA and Real-MRCoNS multiplex real-time PCR assays (M&D, Republic of Korea) use the TaqMan probes 16S rRNA for Staphylo...

  5. Quantitative real-time PCR (qPCR) assay for human-dog-cat species identification and nuclear DNA quantification.

    Science.gov (United States)

    Kanthaswamy, S; Premasuthan, A; Ng, J; Satkoski, J; Goyal, V

    2012-03-01

    In the United States, human forensic evidence collected from crime scenes is usually comingled with biomaterial of canine and feline origins. Knowledge of the concentration of nuclear DNA extracted from a crime scene biological sample and the species from which the sample originated is essential for DNA profiling. The ability to accurately detect and quantify target DNA in mixed-species samples is crucial when target DNA may be overwhelmed by non-target DNA. We have designed and evaluated a species-specific (human, dog and cat) nuclear DNA identification assay based on the TaqMan(®) quantitative real-time PCR (qPCR) technology that can simultaneously detect and measure minute quantities of DNA specific to either humans, dogs and/or cats. The fluorogenic triplex assay employs primers and hydrolysis probes that target the human TH01 locus as well as the dog and cat Melanocortin 1 Receptor (MC1R) sequences in a species-specific manner. We also demonstrate that the assay is a highly sensitive, reliable and robust method for identifying and quantifying mixed-species templates of human-dog-cat origin with as little as 0.4 pg of human and cat nuclear DNA, respectively, and 4.0 pg of dog nuclear DNA.

  6. Detection of viable and dead Listeria monocytogenes on gouda-like cheeses by real-time PCR.

    Science.gov (United States)

    Rudi, K; Naterstad, K; Drømtorp, S M; Holo, H

    2005-01-01

    Surface contamination by Listeria monocytogenes of gouda-like cheeses during processing represents a potential public health problem. The aim of this work was to develop novel real-time PCR diagnostics to detect the presence of viable, dead or viable but not culturable (VBNC) cells on gouda-like cheeses. We used ethidium monoazide bromide (EMA)-PCR for direct quantification of viable and dead cells, while semiquantitative detection of culturable cells below the PCR detection limit (c. 100 CFU g(-1)) was obtained by combining growth and real-time PCR. We were able to quantify the fraction of >0.5% viable cells in a background of dead cells by EMA-PCR, given that the viable cell concentration was above the PCR detection limit. The combined growth and real-time PCR complemented the EMA-PCR, and enabled semiquantitative detection of low levels of culturable cells (10 and 100 CFU g(-1)). The significance of this work is that we have developed a novel concept for detection of viable and potentially infectious L. monocytogenes.

  7. Comparison of a commercial real-time PCR assay, RealCycler® PJIR kit, progenie molecular, to an in-house real-time PCR assay for the diagnosis of Pneumocystis jirovecii infections.

    Science.gov (United States)

    Guillaud-Saumur, Thibaud; Nevez, Gilles; Bazire, Amélie; Virmaux, Michèle; Papon, Nicolas; Le Gal, Solène

    2017-04-01

    We compared the RealCycler® PJIR kit (Progenie Molecular), available in Europe, to an in-house real-time PCR assay for the diagnosis of Pneumocystis jirovecii infections. Excellent agreement was found (concordance rate, 97.4%; Cohen's kappa, 0.918>0.8) showing that this commercial assay represents an alternative method for the diagnosis of P. jirovecii infections.

  8. Multiplex real-time PCR melting curve assay to detect drug-resistant mutations of Mycobacterium tuberculosis.

    Science.gov (United States)

    Luo, Tao; Jiang, Lili; Sun, Weiming; Fu, G; Mei, Jian; Gao, Qian

    2011-09-01

    Early diagnosis of drug-resistant Mycobacterium tuberculosis is urgently needed to optimize treatment regimens and to prevent the transmission of resistant strains. Real-time PCR assays have been developed to detect drug resistance rapidly, but none of them have been widely applied due to their complexity, high cost, or requirement for advanced instruments. In this study, we developed a real-time PCR method based on melting curve analysis of dually labeled probes. Six probes targeting the rpoB 81-bp core region, katG315, the inhA promoter, the ahpC promoter, and embB306 were designed and validated with clinical isolates. First, 10 multidrug-resistant (MDR) strains with a wide mutation spectrum were used to analyze the melting temperature (T(m)) deviations of different mutations by single real-time PCR. All mutations can be detected by significant T(m) reductions compared to the wild type. Then, three duplex real-time PCRs, with two probes in each, were developed to detect mutations in 158 MDR isolates. Comparison of the results with the sequencing data showed that all mutations covered by the six probes were detected with 100% sensitivity and 100% specificity. Our method provided a new way to rapidly detect drug-resistant mutations in M. tuberculosis. Compared to other real-time PCR methods, we use fewer probes, which are labeled with the same fluorophore, guaranteeing that this assay can be used for detection in a single fluorescent channel or can be run on single-channel instruments. In conclusion, we have developed a widely applicable real-time PCR assay to detect drug-resistant mutations in M. tuberculosis.

  9. Use of multiplex real-time PCR for detection of common diarrhea causing protozoan parasites in Egypt.

    Science.gov (United States)

    Nazeer, John T; El Sayed Khalifa, Khalifa; von Thien, Heidrun; El-Sibaei, Mahmoud Mohamed; Abdel-Hamid, Magda Youssef; Tawfik, Ranya Ayman Samir; Tannich, Egbert

    2013-02-01

    Diarrhea is an important cause of morbidity and mortality, worldwide. Giardia intestinalis, Cryptosporidium spp., and Entamoeba histolytica are the most common diarrhea-causing parasitic protozoa. Diagnosis of these parasites is usually performed by microscopy. However, microscopy lacks sensitivity and specificity. Replacing microscopy with more sensitive and specific nucleic acid based methods is hampered by the higher costs, in particular in developing countries. Multiplexing the detection of more than one parasite in a single test by real-time polymerase chain reaction (PCR) has been found to be very effective and would decrease the cost of the test. In the present study, stool samples collected from 396 Egyptian patients complaining of diarrhea along with 202 faecal samples from healthy controls were examined microscopically by direct smear method and after concentration using formol-ethyl acetate. Frozen portions of the same samples were tested by multiplex real-time for simultaneous detection of E. histolytica, G. intestinalis, and Cryptosporidium spp. The results indicate that among diarrheal patients in Egypt G. intestinalis is the most common protozoan parasite, with prevalence rates of 30.5 and 37.1 %, depending on the method used (microscopy vs. multiplex real-time PCR). Cryptosporidium spp. was detected in 1 % of the diarrheal patients by microscopy and in 3 % by real-time PCR. While E. histolytica/dispar was detected in 10.8 % by microscopy, less than one fifth of them (2 %) were found true positive for Entamoeba dispar by real-time PCR. E. histolytica DNA was not detected in any of the diarrheal patients. In comparison with multiplex real-time PCR, microscopy exhibited many false positive and negative cases with the three parasites giving sensitivities and specificities of 100 and 91 % for E. histolytica/dispar, 57.8 and 85.5 % for G. intestinalis, and 33.3 and 100 % for Cryptosporidium spp.

  10. Simultaneous quantitative assessment of circulating cell-free mitochondrial and nuclear DNA by multiplex real-time PCR

    Directory of Open Access Journals (Sweden)

    Peng Xia

    2009-01-01

    Full Text Available Quantification of circulating nucleic acids in plasma and serum could be used as a non-invasive diagnostic tool for monitoring a wide variety of diseases and conditions. We describe here a rapid, simple and accurate multiplex real-time PCR method for direct synchronized analysis of circulating cell-free (ccf mitochondrial (mtDNA and nuclear (nDNA DNA in plasma and serum samples. The method is based on one-step multiplex real-time PCR using a FAM-labeled MGB probe and primers to amplify the mtDNA sequence of the ATP 8 gene, and a VIC-labeled MGB probe and primers to amplify the nDNA sequence of the glycerinaldehyde-3-phosphate-dehydrogenase (GAPDH gene, in plasma and serum samples simultaneously. The efficiencies of the multiplex assays were measured in serial dilutions. Based on the simulation of the PCR reaction kinetics, the relative quantities of ccf mtDNA were calculated using a very simple equation. Using our optimised real-time PCR conditions, close to 100% efficiency was obtained from the two assays. The two assays performed in the dilution series showed very good and reproducible correlation to each other. This optimised multiplex real-time PCR protocol can be widely used for synchronized quantification of mtDNA and nDNA in different samples, with a very high rate of efficiency.

  11. What can be observed in real time PCR and when does it show?

    Science.gov (United States)

    Chigansky, Pavel; Jagers, Peter; Klebaner, Fima C

    2017-06-30

    Real time, or quantitative, PCR typically starts from a very low concentration of initial DNA strands. During iterations the numbers increase, first essentially by doubling, later predominantly in a linear way. Observation of the number of DNA molecules in the experiment becomes possible only when it is substantially larger than initial numbers, and then possibly affected by the randomness in individual replication. Can the initial copy number still be determined? This is a classical problem and, indeed, a concrete special case of the general problem of determining the number of ancestors, mutants or invaders, of a population observed only later. We approach it through a generalised version of the branching process model introduced in Jagers and Klebaner (J Theor Biol 224(3):299-304, 2003. doi: 10.1016/S0022-5193(03)00166-8 ), and based on Michaelis-Menten type enzyme kinetical considerations from Schnell and Mendoza (J Theor Biol 184(4):433-440, 1997). A crucial role is played by the Michaelis-Menten constant being large, as compared to initial copy numbers. In a strange way, determination of the initial number turns out to be completely possible if the initial rate v is one, i.e all DNA strands replicate, but only partly so when [Formula: see text], and thus the initial rate or probability of succesful replication is lower than one. Then, the starting molecule number becomes hidden behind a "veil of uncertainty". This is a special case, of a hitherto unobserved general phenomenon in population growth processes, which will be adressed elsewhere.

  12. RAPID REAL TIME PCR BASED DETECTION OF CELL COUNT IN CASE OF URINARY TRACT INFECTION

    Directory of Open Access Journals (Sweden)

    Poulomi Nandy

    2013-01-01

    Full Text Available Microbial identification and antimicrobial susceptibility testing methods currently used in clinical microbiology laboratories require at least two to three days because they rely on the growth and isolation of micro-organisms. This long, but necessary, delay has enormous consequences on prophylactic usage of antimicrobial drugs. This study was an attempt to reduce this detection time span. Taq Man Real Time PCR has been used as an important tool in the differentiation of Gram nature of bacteria present in UTI patients that allows detection of spiked bacterial 16S rDNA from urine samples within a short span of 5h and also gives us the corresponding cell count of both/either Gram positive and negative organisms present. A standard curve was generated which was used to determine the cell count of control as well as patient samples. Detection could be done in the range of 103 to 106 cells/mL Patient samples screened clustered either in the allele 1 or allele 2 axes, depending on majority concentration of Gram nature of the micro-organisms. The cell counts for control individuals were scattered within 0 to 102, while very few in the range of 104. The case was just reverse for patient group, where most of the points were scattered within 104 to 108. Thus the optimal selection of appropriate antimicrobials (depending on the gram nature by clinicians, will be gradually improved as an increasing number of rapid molecular diagnostic tools for the detection, identification and characterization of infectious agents become commercially available.

  13. Real-time Quantitative RT-PCR for CT9 Level in Human Cancer

    Institute of Scientific and Technical Information of China (English)

    2006-01-01

    CT9 is a recently cloned cancer-testis antigen, which is a member of the bromodomain and extraterminal family.Each member of this protein family contains two N-terminal bromodomain motifs. We investigated the distribution of CT9 in different tissues and the possibility for it to be used as a potential therapeutic target in cancer treament. By using the real-time RT-PCR method and 18SrRNA as an internal standard, we analyzed the CT9 expression in several normal human tissues and in the tissues of patients suffering from cancer. The result of this study shows that the highest level of mRNA is only present in testis tissue because the CT9 expression has not been detected in other normal tissues. In 6 of 10 cases of gastric adenocarcinoma, in 3 of 10 cases of esophageal squamous cell carcinoma, in 2 of 9 cases of endometrial carcinoma and only in 1 of 12 cases of brain cancer, the low level expression of CT9 was detected. In none of the 12 cases of cervical squamous cell carcinoma, the expression of CT9 was detected. Since the high level expression of CT9 is only found in the normal testis tissue, but the low expression in cancer tissues, for example tissues of cervical squamous cell carcinoma, brain cancer, endometrial adenocarcinoma, esophageal squamous cell carcinoma, we conclude that CT9 cannot be used as a cancer therapeutic target molecule for cervical squamous cell carcinoma, brain cancer, endometrial adenocarcinoma, esophageal squamous cell carcinoma.

  14. Identification of nasal blood by real-time RT-PCR.

    Science.gov (United States)

    Sakurada, Koichi; Akutsu, Tomoko; Watanabe, Ken; Yoshino, Mineo

    2012-07-01

    A new approach for the identification of body fluid stains by comparing specific mRNA expression levels has been extensively studied in recent years. Here, we examine whether nasal blood, which is regarded as one of the most difficult types of blood to identify, can be identified by comparing mRNA expression levels of target genes specific to saliva, nasal secretion, and blood. The saliva-specific statherin gene (STATH) was found to be expressed at high levels in not only saliva (dCt value: 1.32±1.39, n=5), but also nasal secretions (dCt value: 0.90±1.14, n=5), while the histatin gene (HTN3) was only expressed at high levels in saliva (dCt value: 1.08±2.35, n=5). We also confirmed that the hemoglobin-beta gene (HBB) showed high expression levels in blood (dCt value: -9.51±0.40, n=5). Four nasal blood stains were found to highly express STATH (dCt value: 5.65±3.98) and HBB (dCt value: -8.79±1.67) but not HTN3, suggesting that the stain samples contained both nasal secretions and blood and can therefore be identified as nasal blood stains. Although menstrual blood showed the same expression pattern as nasal blood, the menstrual blood-specific protein matrix metallopeptidase 7 (MMP7) was not expressed in all nasal blood stain samples. Therefore, its expression levels could be used to discriminate between nasal and menstrual blood. In conclusion, real-time RT-PCR was able to identify nasal blood, although the stability of gene expression in nasal blood stains was low over time, suggesting that this assay may not be effective for older stains. Future work should examine the usefulness of this assay under various environmental conditions.

  15. Survivin isoforms and clinicopathological characteristics in colorectal adenocarcinomas using real-time qPCR

    Institute of Scientific and Technical Information of China (English)

    Anastasia Pavlidou; Maria Dalamaga; Christos Kroupis; George Konstantoudakis; Maria Belimezi; George Athanasas; Kleanthi Dimas

    2011-01-01

    AIM: To investigate three isoforms of survivin in colorectal adenocarcinomas. METHODS: We used the LightCycler Technology (Roche), along with a common forward primer and reverse primers specific for the splice variants and two common hybridization probes labeled with fluorescein and LightCycler- Red fluorophore (LC-Red 640). Real time quantitative polymerase chain reaction (PCR) was performed on cDNAs from 52 tumor specimens from colorectal cancer patients and 10 unrelated normal colorectal tissues. In the patients group, carcinoembryonic antigen (CEA) and CA19-9 tumor markers were also measured immunochemically. RESULTS: Wild type survivin mRNA isoform was expressed in 48% of the 52 tumor samples, survivin-2b in 38% and survivin-ΔΕx3 in 29%, while no expression was found in normal tissues. The mRNA expression of wild type survivin presented a significant correlation with the expression of the ratio of survivin-2b, survivin-ΔΕx3, survivin-2b/wild type survivin and survivin-ΔΕx3/wild type survivin (P < 0.001). The mRNA expression of wildsurvivin and survivin-ΔΕx3 was related with tumor size and invasion (P = 0.006 and P < 0.005, respectively). A significant difference was found between survivin-2b and morphologic cancer type. Also, the ratio of survivin-ΔEx3/ wild-survivin was significantly associated with prognosis. No association was observed between the three isoforms and grade, metastasis, Dukes stage and gender. The three isoforms were not correlated with CEA and CA19-9. CONCLUSION: Survivin isoforms may play a role in cell apoptosis and their quantification could provide information about clinical management of patients suffering from colorectal cancer.

  16. Label-free detection of gliadin food allergen mediated by real-time apta-PCR.

    Science.gov (United States)

    Pinto, Alessandro; Polo, Pedro Nadal; Henry, Olivier; Redondo, M Carmen Bermudo; Svobodova, Marketa; O'Sullivan, Ciara K

    2014-01-01

    Celiac disease is an immune-mediated enteropathy triggered by the ingestion of gluten. The only effective treatment consists in a lifelong gluten-free diet, requiring the food industry to tightly control the gluten contents of their products. To date, several gluten quantification approaches using antibodies are available and recommended by the legal authorities, such as Codex Alimentarius. However, whilst these antibody-based tests exhibit high sensitivity and specificity, the production of antibodies inherently requires the killing of host animals and is time-consuming and relatively expensive. Aptamers are structured single-stranded nucleic acid ligands that bind with high affinity and specificity to their cognate target, and aiming for a cost-effective viable alternative to the use of antibodies. Herein, we report the systematic evolution of ligands by exponential enrichment (SELEX)-based selection of a DNA aptamer against gliadin from a combinatorial DNA library and its application in a novel detection assay. Taking into account the hydrophobic nature of the gliadin target, a microtitre plate format was exploited for SELEX, where the target was immobilised via hydrophobic interactions, thus exposing aptatopes accessible for interaction with the DNA library. Evolution was followed using surface plasmon resonance, and following eight rounds of SELEX, the enriched DNA pool was cloned, sequenced and a clear consensus motif was identified. An apta-PCR assay was developed where competition for the aptamer takes place between the surface-immobilised gliadin and gliadin in the target sample, akin to an ELISA competitive format where the more target present in the sample, the less aptamer will bind to the immobilised gliadin. Following competition, any aptamer bound to the immobilised gliadin was heat-eluted and quantitatively amplified using real-time PCR, achieving a detection limit of approx. 2 nM (100 ng mL(-1)). The specificity of the selected aptamer was

  17. Comparison of Real-Time PCR, Reverse Transcriptase Real-Time PCR, Loop-Mediated Isothermal Amplification, and the FDA Conventional Microbiological Method for the Detection of Salmonella spp. in Produce ▿ †

    Science.gov (United States)

    Zhang, Guodong; Brown, Eric W.; González-Escalona, Narjol

    2011-01-01

    Contamination of foods, especially produce, with Salmonella spp. is a major concern for public health. Several methods are available for the detection of Salmonella in produce, but their relative efficiency for detecting Salmonella in commonly consumed vegetables, often associated with outbreaks of food poisoning, needs to be confirmed. In this study, the effectiveness of three molecular methods for detection of Salmonella in six produce matrices was evaluated and compared to the FDA microbiological detection method. Samples of cilantro (coriander leaves), lettuce, parsley, spinach, tomato, and jalapeno pepper were inoculated with Salmonella serovars at two different levels (105 and Bacteriological Analytical Manual) and by three molecular methods: quantitative real-time PCR (qPCR), quantitative reverse transcriptase real-time PCR (RT-qPCR), and loop-mediated isothermal amplification (LAMP). Comparable results were obtained by these four methods, which all detected as little as 2 CFU of Salmonella cells/25 g of produce. All control samples (not inoculated) were negative by the four methods. RT-qPCR detects only live Salmonella cells, obviating the danger of false-positive results from nonviable cells. False negatives (inhibition of either qPCR or RT-qPCR) were avoided by the use of either a DNA or an RNA amplification internal control (IAC). Compared to the conventional culture method, the qPCR, RT-qPCR, and LAMP assays allowed faster and equally accurate detection of Salmonella spp. in six high-risk produce commodities. PMID:21803916

  18. Comparison of real-time PCR, reverse transcriptase real-time PCR, loop-mediated isothermal amplification, and the FDA conventional microbiological method for the detection of Salmonella spp. in produce.

    Science.gov (United States)

    Zhang, Guodong; Brown, Eric W; González-Escalona, Narjol

    2011-09-01

    Contamination of foods, especially produce, with Salmonella spp. is a major concern for public health. Several methods are available for the detection of Salmonella in produce, but their relative efficiency for detecting Salmonella in commonly consumed vegetables, often associated with outbreaks of food poisoning, needs to be confirmed. In this study, the effectiveness of three molecular methods for detection of Salmonella in six produce matrices was evaluated and compared to the FDA microbiological detection method. Samples of cilantro (coriander leaves), lettuce, parsley, spinach, tomato, and jalapeno pepper were inoculated with Salmonella serovars at two different levels (10(5) and Bacteriological Analytical Manual) and by three molecular methods: quantitative real-time PCR (qPCR), quantitative reverse transcriptase real-time PCR (RT-qPCR), and loop-mediated isothermal amplification (LAMP). Comparable results were obtained by these four methods, which all detected as little as 2 CFU of Salmonella cells/25 g of produce. All control samples (not inoculated) were negative by the four methods. RT-qPCR detects only live Salmonella cells, obviating the danger of false-positive results from nonviable cells. False negatives (inhibition of either qPCR or RT-qPCR) were avoided by the use of either a DNA or an RNA amplification internal control (IAC). Compared to the conventional culture method, the qPCR, RT-qPCR, and LAMP assays allowed faster and equally accurate detection of Salmonella spp. in six high-risk produce commodities.

  19. Real-time PCR法检测羊奶粉中羊源性成分%Identification of Sheep Milk Powder by Real-time PCR

    Institute of Scientific and Technical Information of China (English)

    姚卢悦; 李宇

    2015-01-01

    建立Real-time PCR鉴别羊奶粉的定性检测方法.通过对试剂盒提取DNA方法的改进得到适用于Real-time PCR测试的样品DNA.使用Real-time PCR法对羊奶粉中的羊源性成分进行鉴别.并通过普通PCR电泳方法对Real-time PCR方法进行验证,证明Real-time PCR方法的可行性.

  20. Duplex real-time PCR assay for rapid identification of Staphylococcus aureus isolates from dairy cow milk.

    Science.gov (United States)

    Pilla, Rachel; Snel, Gustavo G M; Malvisi, Michela; Piccinini, Renata

    2013-05-01

    Staphylococcus aureus isolates from dairy cow mastitis are not always consistent with the characteristic morphology described, and molecular investigation is often needed. The aim of the study was to develop a duplex real-time PCR assay for rapid identification of Staph. aureus isolates, targeting both nuc and Sa442. Overall, 140 isolates collected from dairy cow mastitis in 90 different herds, were tested. All strains had been identified using morphological and biochemical characteristics. DNA from each strain was amplified in real-time PCR assay, to detect nuc or Sa442. Thereafter, a duplex real-time PCR assay was performed, and specificity of the amplified products was assessed by high resolution melting curve analysis. Out of 124 Staph. aureus isolates, 33 did not show the typical morphology or enzymic activity; in 118 strains, the two melt-curve peaks consistent with nuc and Sa442 were revealed, while 2 isolates showed only the peak consistent with Sa442. Four isolates bacteriologically identified as Staph. aureus, were PCR-negative and were further identified as Staph. pseudintermedius by sequencing. Staph. pseudintermedius and coagulase-negative staphylococci did not carry nuc or Sa442. The results showed the correct identification of all isolates, comprehending also coagulase-or nuc-negative Staph. aureus, while other coagulase-positive Staphylococci were correctly identified as non-Staph. aureus. Both sensitivity and specificity were 100%. High resolution melting analysis allowed easy detection of unspecific products. Finally, the duplex real-time PCR was applied directly to 40 milk samples, to detect infected mammary quarters. The assay confirmed the results of bacteriological analysis, on Staph. aureus-positive or-negative samples. Therefore, the proposed duplex real-time PCR could be used in laboratory routine as a cost-effective and powerful tool for high-throughput identification of atypical Staph. aureus isolates causing dairy cow mastitis. Also, it

  1. Development of Hepatitis C Virus Genotyping by Real-Time PCR Based on the NS5B Region

    Science.gov (United States)

    Nakatani, Sueli M.; Santos, Carlos A.; Riediger, Irina N.; Krieger, Marco A.; Duarte, Cesar A. B.; Lacerda, Marco A.; Biondo, Alexander W.; Carilho, Flair J.; Ono-Nita, Suzane K.

    2010-01-01

    Background Hepatitis C virus (HCV) genotyping is the most significant predictor of the response to antiviral therapy. The aim of this study was to develop and evaluate a novel real-time PCR method for HCV genotyping based on the NS5B region. Methodology/Principal Findings Two triplex reaction sets were designed, one to detect genotypes 1a, 1b and 3a; and another to detect genotypes 2a, 2b, and 2c. This approach had an overall sensitivity of 97.0%, detecting 295 of the 304 tested samples. All samples genotyped by real-time PCR had the same type that was assigned using LiPA version 1 (Line in Probe Assay). Although LiPA v. 1 was not able to subtype 68 of the 295 samples (23.0%) and rendered different subtype results from those assigned by real-time PCR for 12/295 samples (4.0%), NS5B sequencing and real-time PCR results agreed in all 146 tested cases. Analytical sensitivity of the real-time PCR assay was determined by end-point dilution of the 5000 IU/ml member of the OptiQuant HCV RNA panel. The lower limit of detection was estimated to be 125 IU/ml for genotype 3a, 250 IU/ml for genotypes 1b and 2b, and 500 IU/ml for genotype 1a. Conclusions/Significance The total time required for performing this assay was two hours, compared to four hours required for LiPA v. 1 after PCR-amplification. Furthermore, the estimated reaction cost was nine times lower than that of available commercial methods in Brazil. Thus, we have developed an efficient, feasible, and affordable method for HCV genotype identification. PMID:20405017

  2. Rapid DNA extraction protocol for detection of alpha-1 antitrypsin deficiency from dried blood spots by real-time PCR.

    Science.gov (United States)

    Struniawski, R; Szpechcinski, A; Poplawska, B; Skronski, M; Chorostowska-Wynimko, J

    2013-01-01

    The dried blood spot (DBS) specimens have been successfully employed for the large-scale diagnostics of α1-antitrypsin (AAT) deficiency as an easy to collect and transport alternative to plasma/serum. In the present study we propose a fast, efficient, and cost effective protocol of DNA extraction from dried blood spot (DBS) samples that provides sufficient quantity and quality of DNA and effectively eliminates any natural PCR inhibitors, allowing for successful AAT genotyping by real-time PCR and direct sequencing. DNA extracted from 84 DBS samples from chronic obstructive pulmonary disease patients was genotyped for AAT deficiency variants by real-time PCR. The results of DBS AAT genotyping were validated by serum IEF phenotyping and AAT concentration measurement. The proposed protocol allowed successful DNA extraction from all analyzed DBS samples. Both quantity and quality of DNA were sufficient for further real-time PCR and, if necessary, for genetic sequence analysis. A 100% concordance between AAT DBS genotypes and serum phenotypes in positive detection of two major deficiency S- and Z- alleles was achieved. Both assays, DBS AAT genotyping by real-time PCR and serum AAT phenotyping by IEF, positively identified PI*S and PI*Z allele in 8 out of the 84 (9.5%) and 16 out of 84 (19.0%) patients, respectively. In conclusion, the proposed protocol noticeably reduces the costs and the hand-on-time of DBS samples preparation providing genomic DNA of sufficient quantity and quality for further real-time PCR or genetic sequence analysis. Consequently, it is ideally suited for large-scale AAT deficiency screening programs and should be method of choice.

  3. Development of hepatitis C virus genotyping by real-time PCR based on the NS5B region.

    Directory of Open Access Journals (Sweden)

    Sueli M Nakatani

    Full Text Available BACKGROUND: Hepatitis C virus (HCV genotyping is the most significant predictor of the response to antiviral therapy. The aim of this study was to develop and evaluate a novel real-time PCR method for HCV genotyping based on the NS5B region. METHODOLOGY/PRINCIPAL FINDINGS: Two triplex reaction sets were designed, one to detect genotypes 1a, 1b and 3a; and another to detect genotypes 2a, 2b, and 2c. This approach had an overall sensitivity of 97.0%, detecting 295 of the 304 tested samples. All samples genotyped by real-time PCR had the same type that was assigned using LiPA version 1 (Line in Probe Assay. Although LiPA v. 1 was not able to subtype 68 of the 295 samples (23.0% and rendered different subtype results from those assigned by real-time PCR for 12/295 samples (4.0%, NS5B sequencing and real-time PCR results agreed in all 146 tested cases. Analytical sensitivity of the real-time PCR assay was determined by end-point dilution of the 5000 IU/ml member of the OptiQuant HCV RNA panel. The lower limit of detection was estimated to be 125 IU/ml for genotype 3a, 250 IU/ml for genotypes 1b and 2b, and 500 IU/ml for genotype 1a. CONCLUSIONS/SIGNIFICANCE: The total time required for performing this assay was two hours, compared to four hours required for LiPA v. 1 after PCR-amplification. Furthermore, the estimated reaction cost was nine times lower than that of available commercial methods in Brazil. Thus, we have developed an efficient, feasible, and affordable method for HCV genotype identification.

  4. Detection and quantitation of two cucurbit criniviruses in mixed infection by real-time RT-PCR.

    Science.gov (United States)

    Abrahamian, Peter E; Seblani, Rewa; Sobh, Hana; Abou-Jawdah, Yusuf

    2013-11-01

    Cucurbit chlorotic yellows virus (CCYV) and Cucurbit yellow stunting disorder virus (CYSDV) are whitefly-transmitted criniviruses infecting cucurbit crops inducing similar symptoms. Single and multiplex RT-PCR protocols were developed and evaluated on cucurbit samples collected from commercial greenhouses. Primers and probes were designed from the highly conserved heat shock protein 70 homolog (Hsp70h) gene. Conventional RT-PCR and multiplex RT-PCR assays showed high specificity and suitability for routine screening. TaqMan-based quantitative real-time RT-PCR (RT-qPCR) protocols were also developed for the detection and quantitation of both viruses occurring in single or mixed infection. The assays proved to be highly specific with no cross amplification. RT-qPCR assays showed a 100-1000 times improved sensitivity over conventional RT-PCR. Virus titers in mixed infections were compared to singly infected plants by RT-qPCR. CYSDV and CCYV titers decreased in double infected plants. This paper reports highly specific conventional RT-PCR and quantitative real-time PCR assays for detection, quantitation and differentiation between two closely related cucurbit-infecting criniviruses.

  5. Detection of Bartonella spp. DNA in clinical specimens using an internally controlled real-time PCR assay

    NARCIS (Netherlands)

    Bergmans, Anneke M C; Rossen, John W A

    2013-01-01

    Bartonella henselae is the causative agent of cat-scratch disease (CSD), usually presenting itself as a -self-limiting lymphadenopathy. In this chapter an internally controlled Taqman probe-based real-time PCR targeting the groEL gene of Bartonella spp. is described. This assay allows for the rapid,

  6. Development of a non invasion real-time PCR assay for the quantitation of chicken parvovirus in fecal swabs

    Science.gov (United States)

    The present study describes the development of a real time Taqman polymerase chain reaction (PCR) assay using a fluorescent labeled probe for the detection and quantitation of chicken parvovirus (ChPV) in feces. The primers and probes were designed based on the nucleotide sequence of the non struct...

  7. Real-time PCR for detection and quantification of fungal and oomycete tomato pathogens in plant and soil samples

    NARCIS (Netherlands)

    Lievens, B.; Brouwer, M.; Vanachter, A.C.R.C.; Cammue, B.P.A.; Thomma, B.P.H.J.

    2006-01-01

    Although new, rapid detection and identification technologies are becoming available more and more for various plant pathogens, pathogen quantification remains one of the main challenges in the disease management of many crops. Currently, real-time polymerase chain reaction (PCR) is the most straigh

  8. Development of Real-Time Reverse Transcriptase PCR Assays for the Detection of Punta Toro Virus and Pichinde Virus

    Science.gov (United States)

    2016-09-09

    agarose (Lonza, Basel, Switzerland) and a secondary overlay containing 5% 109 neutral red (Life Technologies, Grand Isle, NY). Vero E6 cells were...et al., 1992), and these inhibitors can carry through RNA 190 preparation methods, affecting real-time RT-PCR results and impacting assay sensitivity

  9. Detection of Zika Virus in Desiccated Mosquitoes by Real-Time Reverse Transcription PCR and Plaque Assay

    Science.gov (United States)

    Savage, Harry M.

    2017-01-01

    We assayed Zika virus–infected mosquitoes stored at room temperature for <30 days for live virus by using plaque assay and virus RNA by using real-time reverse transcription PCR. Viable virus was detected in samples stored <10 days, and virus RNA was detected in samples held for 30 days. PMID:28075325

  10. Assessment of Status of rpoB Gene in FNAC Samples of Tuberculous Lymphadenitis by Real-Time PCR

    Directory of Open Access Journals (Sweden)

    Amita Raoot

    2012-01-01

    Full Text Available Introduction. Multidrug resistance tuberculosis (MDR TB, the combined resistance of Mycobacterium tuberculosis to isoniazid (INH and rifampin (RFM is a major public health problem in India as it ranks second among the MDR-TB high burden countries worldwide. WHO recommends RFM resistance as a “surrogate marker” for detecting MDR. FNAC is the most widely used noninvasive investigative technique for TB lymphadenitis. Real-time polymerase chain reaction, an extremely versatile technique can be used for the timely detection and treatment of MDR TB by assessing RFM resistance status in the FNAC samples of TB lymphadenitis. Aim. To assess the status of rpoB gene by real-time PCR in FNAC samples of TB lymphadenitis. Materials and Methods. Thirty FNAC samples from patients with persistent LAP or appearance of new LAP after 5 months or more of Anti Tubercular Treatment were assessed for status of rpoB gene by Real-Time PCR using probe covering the “hot spot resistance” region of the rpoB gene. Result. By using probe covering codons 531 and 526 of rpoB gene, we could detect 17 of 30 (56.7% rifampin resistant isolate. The PCR could detect Mtb DNA in 100% of cases. Conclusion. Use of molecular methods like Real-Time PCR for detection of MDR-TB in FNAC samples is time saving, logical and economical approach over the culture based method.

  11. Sensitive detection of African swine fever virus using real-time PCR with a 5' conjugated minor groove binding probe

    DEFF Research Database (Denmark)

    McKillan, John; McMenamy, Michael; Hjertner, Bernt;

    2010-01-01

    The design of a 5′ conjugated minor groove binder (MGB) probe real-time PCR assay is described for the rapid, sensitive and specific detection of African swine fever virus (ASFV) DNA. The assay is designed against the 9GL region and is capable of detecting 20 copies of a DNA standard. It does...

  12. Detection of Campylobacter species and Arcobacter butzleri in stool samples by use of real-time multiplex PCR

    NARCIS (Netherlands)

    R.F. de Boer (Richard); A. Ott (Alewijn); P. Güren (Pinar); E. van Zanten; A.F. van Belkum (Alex); A.M.D. Kooistra-Smid

    2013-01-01

    textabstractThe presence of Campylobacter (or Campylobacter-like) species in stools from patients suspected of infectious gastroenteritis (n = 493) was investigated using real-time PCR for detection of Arcobacter butzleri (hsp60 gene), Campylobacter coli (ceuE gene), Campylobacter jejuni (mapA), fiv

  13. Detection of Yersinia pestis using real-time PCR in patients with suspected bubonic plague.

    Science.gov (United States)

    Riehm, Julia M; Rahalison, Lila; Scholz, Holger C; Thoma, Bryan; Pfeffer, Martin; Razanakoto, Léa Mamiharisoa; Al Dahouk, Sascha; Neubauer, Heinrich; Tomaso, Herbert

    2011-02-01

    Yersinia (Y.) pestis, the causative agent of plague, is endemic in natural foci of Asia, Africa, and America. Real-time PCR assays have been described as rapid diagnostic tools, but so far none has been validated for its clinical use. In a retrospective clinical study we evaluated three real-time PCR assays in two different assay formats, 5'-nuclease and hybridization probes assays. Lymph node aspirates from 149 patients from Madagascar with the clinical diagnosis of bubonic plague were investigated for the detection of Y. pestis DNA. Results of real-time PCR assays targeting the virulence plasmids pPCP1 (pla gene), and pMT1 (caf1, Ymt genes) were compared with an F1-antigen immunochromatographic test (ICT) and cultivation of the organism. Out of the 149 samples an infection with Y. pestis was confirmed by culture in 47 patients while ICT was positive in 88 including all culture proven cases. The best real-time PCR assay was the 5'-nuclease assay targeting pla which was positive in 120 cases. In conclusion, the 5'-nuclease assay targeting pla can be recommended as diagnostic tool for establishing a presumptive diagnosis when bubonic plague is clinically suspected. Copyright © 2010 Elsevier Ltd. All rights reserved.

  14. Real-time PCR for detection and quantification of fungal and oomycete tomato pathogens in plant and soil samples

    NARCIS (Netherlands)

    Lievens, B.; Brouwer, M.; Vanachter, A.C.R.C.; Cammue, B.P.A.; Thomma, B.P.H.J.

    2006-01-01

    Although new, rapid detection and identification technologies are becoming available more and more for various plant pathogens, pathogen quantification remains one of the main challenges in the disease management of many crops. Currently, real-time polymerase chain reaction (PCR) is the most straigh

  15. Improved HF183 quantitative real-time PCR assay for characterization of human fecal pollution in ambient surface water samples

    Science.gov (United States)

    Real-time quantitative PCR assays that target the human-associated HF183 bacterial cluster have been found to be some of the top performing methods for the characterization of human fecal pollution in ambient surface waters. The United States Environmental Protection Agency is planning to conduct a ...

  16. Detection of non-O157 STEC in ground beef using the GeneDisc real-time PCR system

    Science.gov (United States)

    Certain non-O157 Shiga toxin-producing Escherichia coli (STEC) serogroups have emerged as important public health threats. The development of methods for rapid and reliable detection of this heterogeneous group of pathogens has been challenging. A GeneDisc real-time PCR assay was evaluated for det...

  17. Quantification of Faecalibacterium prausnitzii- and Subdoligranulum variabile-like bacteria in the cecum of chickens by real-time PCR

    DEFF Research Database (Denmark)

    Lund, Marianne; Friis-Holm, Lotte Bjerrum; Pedersen, Karl

    2010-01-01

    , and in hatcher material. Quantification of this group of F. prausnitzii-S. variabile-like bacteria has not been performed before by real-time PCR, but results confirm previous results obtained by cloning and sequencing showing that the F. prausnitzii-S. variabile-like group of bacteria constitutes a major...

  18. Development of a new real-time PCR system for simultaneous detection of bacteria and fungi in pathological samples.

    Science.gov (United States)

    Fukumoto, Hitomi; Sato, Yuko; Hasegawa, Hideki; Saeki, Hidehisa; Katano, Harutaka

    2015-01-01

    A novel system for simultaneous detection of pathogenic bacteria and fungi in pathological samples was developed using a real-time polymerase chain reaction (PCR) system. This system, designated the "multi-microbial real-time PCR", has the potential to simultaneously detect 68 bacterial and 9 fungal species in a 96-well plate format. All probe-primer sets were designed to produce amplicons smaller than 210 bp using formalin-fixed paraffin-embedded samples as input. The specificity and sensitivity of each probe-primer set were tested against DNA extracted from pure cultures of specific pathogens. The multi-microbial real-time PCR system revealed profiles of microorganism infection in lung samples collected at autopsy from 10 patients with acquired immunodeficiency syndrome. Staphylococcus aureus was the most common microbe detected (n=8), but with low copy numbers. High copy numbers of Pseudomonas aeruginosa were detected in the lung samples with abscess (n=6). Enterococcus faecium (n=6), Elizabethkingia meningoseptica (n=4), and Candida albicans (n=4) were also frequently detected. In addition, a latent infection of Mycobacterium tuberculosis was detected in one case of pneumonia. In conclusion, this multi-microbial real-time PCR system can be useful for detecting bacteria and fungi in pathological specimens from patients with uncertain diagnoses.

  19. Combined use of real-time PCR and nested sequence-based typing in survey of human Legionella infection.

    Science.gov (United States)

    Qin, T; Zhou, H; Ren, H; Shi, W; Jin, H; Jiang, X; Xu, Y; Zhou, M; Li, J; Wang, J; Shao, Z; Xu, X

    2016-07-01

    Legionnaires' disease (LD) is a globally distributed systemic infectious disease. The burden of LD in many regions is still unclear, especially in Asian countries including China. A survey of Legionella infection using real-time PCR and nested sequence-based typing (SBT) was performed in two hospitals in Shanghai, China. A total of 265 bronchoalveolar lavage fluid (BALF) specimens were collected from hospital A between January 2012 and December 2013, and 359 sputum specimens were collected from hospital B throughout 2012. A total of 71 specimens were positive for Legionella according to real-time PCR focusing on the 5S rRNA gene. Seventy of these specimens were identified as Legionella pneumophila as a result of real-time PCR amplification of the dotA gene. Results of nested SBT revealed high genetic polymorphism in these L. pneumophila and ST1 was the predominant sequence type. These data revealed that the burden of LD in China is much greater than that recognized previously, and real-time PCR may be a suitable monitoring technology for LD in large sample surveys in regions lacking the economic and technical resources to perform other methods, such as urinary antigen tests and culture methods.

  20. Characterization of cytokine expression induced by avian influenza virus infection with real-time RT-PCR

    Science.gov (United States)

    Knowledge of how birds react to infection from avian influenza virus is critical to understanding disease pathogenesis and host response. The use of real-time (R), reverse-transcriptase (RT), PCR to measure innate immunity, including cytokine and interferon gene expression, has become a standard tec...

  1. Detection of Campylobacter species and Arcobacter butzleri in stool samples by use of real-time multiplex PCR

    NARCIS (Netherlands)

    R.F. de Boer (Richard); A. Ott (Alewijn); P. Güren (Pinar); E. van Zanten; A.F. van Belkum (Alex); A.M.D. Kooistra-Smid

    2013-01-01

    textabstractThe presence of Campylobacter (or Campylobacter-like) species in stools from patients suspected of infectious gastroenteritis (n = 493) was investigated using real-time PCR for detection of Arcobacter butzleri (hsp60 gene), Campylobacter coli (ceuE gene), Campylobacter jejuni (mapA),

  2. Measurement of bacterial gene expression in vivo by laser capture microdissection and quantitative real-time RT-PCR

    DEFF Research Database (Denmark)

    Schou, Kirstine Klitgaard; Jensen, Tim Kåre; Angen, Øystein

    2007-01-01

    Due to the relative small number of bacterial pathogens present in an infected host, exploration of pathogen gene expression in vivo is challenging. This study reports the development of a protocol for quantifying bacterial gene expression in vivo in Actinobacillus pleuropneumoniae using laser ca...... capture microdissection and real-time quantitative RT-PCR....

  3. Interlaboratory evaluation of different extraction and real-time PCR methods for detection of Coxiella burnetii DNA in serum

    NARCIS (Netherlands)

    Tilburg, Jeroen J. H. C.; Melchers, Willem J. G.; Pettersson, Annika M.; Rossen, John W. A.; Hermans, Mirjam H. A.; van Hannen, Erik J.; Nabuurs-Franssen, Marrigje H.; de Vries, Maaike C.; Horrevorts, Alphons M.; Klaassen, Corne H. W.

    2010-01-01

    In the Netherlands, there is an ongoing and unparalleled outbreak of Q fever. Rapid and reliable methods to identify patients infected with Coxiella burnetii, the causative agent of Q fever, are urgently needed. We evaluated the performance of different DNA extraction methods and real-time PCR

  4. Interlaboratory evaluation of different extraction and real-time PCR methods for detection of Coxiella burnetii DNA in serum.

    NARCIS (Netherlands)

    Tilburg, J.J.; Melchers, W.J.G.; Pettersson, A.M.; Rossen, J.W.; Hermans, M.H.; Hannen, E.J.M.; Nabuurs-Franssen, M.H.; Vries, M.C. de; Horrevorts, A.M.; Klaassen, C.H.

    2010-01-01

    In the Netherlands, there is an ongoing and unparalleled outbreak of Q fever. Rapid and reliable methods to identify patients infected with Coxiella burnetii, the causative agent of Q fever, are urgently needed. We evaluated the performance of different DNA extraction methods and real-time PCR

  5. Quantitative detection of the free-living amoeba Hartmannella vermiformis in surface water by using real-time PCR

    NARCIS (Netherlands)

    Kuiper, M.W.; Valster, R.M.; Wullings, B.A.; Boonstra, H.; Smidt, H.; Kooij, van der D.

    2006-01-01

    A real-time PCR-based method targeting the 18S rRNA gene was developed for the quantitative detection of Hartmannella vermiformis, a free-living amoeba which is a potential host for Legionella pneumophila in warm water systems and cooling towers. The detection specificity was validated using genomic

  6. Quantitative detection of the free-living amoeba Hartmannella vermiformis in surface water by using real-time PCR

    NARCIS (Netherlands)

    Kuiper, M.W.; Valster, R.M.; Wullings, B.A.; Boonstra, H.; Smidt, H.; Kooij, van der D.

    2006-01-01

    A real-time PCR-based method targeting the 18S rRNA gene was developed for the quantitative detection of Hartmannella vermiformis, a free-living amoeba which is a potential host for Legionella pneumophila in warm water systems and cooling towers. The detection specificity was validated using genomic

  7. Rapid detection of Panton-Valentine leukocidin from clinical isolates of Staphylococcus aureus strains by real-time PCR

    NARCIS (Netherlands)

    Deurenberg, Ruud H; Vink, Cornelis; Driessen, Christel; Bes, Michèle; London, Nancy; Etienne, Jerome; Stobberingh, Ellen E

    2004-01-01

    To allow rapid identification of Panton-Valentine leukocidin (PVL)-producing Staphylococcus aureus strains, a real-time PCR assay for detection of PVL was developed. This assay is convenient, since it can be applied directly on bacterial suspensions and does not require previous DNA purification.

  8. Multiplex real-time PCR assays for the identification of the potato cyst and tobacco cyst nematodes

    Science.gov (United States)

    TaqMan primer-probe sets were developed for the detection and identification of potato cyst nematodes (PCN) Globodera pallida and G. rostochiensis using two-tube, multiplex real-time PCR. One tube contained a primer-probe set specific for G. pallida (pale cyst nematode) multiplexed with another prim...

  9. A real-time PCR assay for the specific identification of serotype O : 9 of Yersinia enterocolitica

    DEFF Research Database (Denmark)

    Jacobsen, N.R.; Bogdanovich, T.; Skurnik, M.

    2005-01-01

    A real-time PCR assay was developed based on a 18 1 -bp fragment of the recently cloned per gene, including an internal amplification control (124 bp), for the detection of Yersinia enterocolitica 0:9 (Ye 0:9). The validation included 48 Ye 0:9, 33 Y enterocolitica non-0:9 and 35 other closely...

  10. Usefulness of Multiplex Real-Time PCR for Simultaneous Pathogen Detection and Resistance Profiling of Staphylococcal Bacteremia

    Directory of Open Access Journals (Sweden)

    Yousun Chung

    2016-01-01

    Full Text Available Staphylococci are the leading cause of nosocomial blood stream infections. Fast and accurate identification of staphylococci and confirmation of their methicillin resistance are crucial for immediate treatment with effective antibiotics. A multiplex real-time PCR assay that targets mecA, femA specific for S. aureus, femA specific for S. epidermidis, 16S rRNA for universal bacteria, and 16S rRNA specific for staphylococci was developed and evaluated with 290 clinical blood culture samples containing Gram-positive cocci in clusters (GPCC. For the 262 blood cultures identified to the species level with the MicroScan WalkAway system (Siemens Healthcare Diagnostics, USA, the direct real-time PCR assay of positive blood cultures showed very good agreement for the categorization of staphylococci into methicillin-resistant S. aureus (MRSA, methicillin-susceptible S. aureus (MSSA, methicillin-resistant S. epidermidis (MRSE, methicillin-susceptible S. epidermidis (MSSE, methicillin-resistant non-S. epidermidis CoNS (MRCoNS, and methicillin-susceptible non-S. epidermidis CoNS (MSCoNS (κ=0.9313. The direct multiplex real-time PCR assay of positive blood cultures containing GPCC can provide essential information at the critical point of infection with a turnaround time of no more than 4 h. Further studies should evaluate the clinical outcome of using this rapid real-time PCR assay in glycopeptide antibiotic therapy in clinical settings.

  11. Real-time PCR TaqMan assay for detecting Trichophyton tonsurans, a causative agent of tinea capitis, from hairbrushes.

    Science.gov (United States)

    Sugita, T; Shiraki, Y; Hiruma, M

    2006-09-01

    Tinea capitis caused by Trichophyton tonsurans is currently an epidemic in the United States, Europe, and Japan, and the cultivation of this microorganism is necessary for a definitive diagnosis. We recently developed a real-time PCR TaqMan assay as a culture-independent method for the rapid detection of T. tonsurans from hairbrushes.

  12. Vitality Stains and Real Time PCR Studies to Delineate the Interactions of Pichia anomala and Aspergillus flavus

    Science.gov (United States)

    The objectives of this study were to probe the effect of the yeast, P. anomala against A flavus by using real time RT-PCR technique and vitality fluorescent stains. Yeast and fungi were inoculated into a 250 ml-flask containing 50 ml potato dextrose broth (PDB) at yeast to fungus (Y : F) ratios of ...

  13. Direct Detection of Escherichia coli Virulence Genes by Real-Time PCR in Fecal Samples from Bats in Brazil.

    Science.gov (United States)

    Cabal, Adriana; Pereira, Maria J; Aguiar, Ludmilla M S; Domínguez, Lucas; Fonseca, Carlos; Álvarez, Julio; Drexler, Jan F; Gortázar, Christian

    2015-10-01

    Guano samples from 412 Brazilian bats were screened with real-time PCR for the virulence genes (eae, est, elt, stx1, stx2, ehxA, invA, bfpA, aggR) representing five intestinal pathotypes of Escherichia coli. From 82 pooled samples, 22% contained Escherichia coli DNA, and eae, est, bfpA, aggR were detected.

  14. Validation and standardization of gene expression data for microarray and real time quantitative PCR using universal external RNA controls

    Science.gov (United States)

    This presentation will introduce newly developed universal external ribonucleic acid (RNA) controls and their applications on different platforms of microarray and quantitative real time polymerase chain reaction (qRT-PCR) including SYBR Green® and TaqMan® probe-based chemistries. Data obtained fro...

  15. EGFR Mutations Detection in Non-small Cell Lung Cancer Tissues by Real-time PCR and DNA Sequencing

    Directory of Open Access Journals (Sweden)

    Qinghua ZHOU

    2009-12-01

    Full Text Available Background and objective Small molecule tyrosine kinase inhibitors (TKIs, such as gefitinib and erlotinib that target the kinase domain of epidermal growth factor receptor (EGFR are making successful progression for advanced non-small cell lung cancer patients treatment. The growing evidences revealed that EGFR exon 19 and 21 mutation status in NSCLC patients was correlated with the outcome for EGFR-TKI treatment. In this study, two methods of Real-time PCR and DNA sequencing were compared to detected EGFR exon 19 and 21 mutations. Methods EGFR exon19 mutation del-E746-A750 and exon 21mutation L858R were detected by Real-time PCR and DNA sequencing in 103 NSCLC patients. Chi-square test was used to analyze the consistance. Results There was no significant difference between the two methods. However, Real-time PCR was more convenient and sensitive compared to DNA sequencing. Conclusion Real-time PCR was more suitable for clinical testing than DNA sequencing.

  16. Rapid Detection of KPC, NDM, and OXA-48-Like Carbapenemases by Real-Time PCR from Rectal Swab Surveillance Samples

    Science.gov (United States)

    Lee, Tracy D.; Adie, Kathleen; McNabb, Alan; Purych, Dale; Mannan, Kulvinder; Azana, Robert; Ng, Corrinne; Tang, Patrick

    2015-01-01

    We describe a multiplex real-time PCR assay for use on the ABI 7500 Fast TaqMan platform to detect all currently described Klebsiella pneumoniae carbapenemases (KPC), New Delhi metallo-β-lactamases (NDM), and the OXA-48-like family of carbapenemases from bacterial culture lysates or sample enrichment broth lysates. PMID:26019195

  17. A novel method to compensate for different amplification efficiencies between patient DNA samples in quantitative real-time PCR

    NARCIS (Netherlands)

    J.P.P. Meijerink (Jules); C. Mandigers; L. van de Locht; E. Tonnissen; F. Goodsaid; J. Raemaekers (John)

    2001-01-01

    textabstractQuantification of residual disease by real-time polymerase chain reaction (PCR) will become a pivotal tool in the development of patient-directed therapy. In recent years, various protocols to quantify minimal residual disease in leukemia or lymphoma patients have been

  18. Diagnosis of pulmonary infection with Toxoplasma gondii in immunocompromised HIV-positive patients by real-time PCR

    DEFF Research Database (Denmark)

    Petersen, E.; Edvinsson, B.; Lundgren, Bettina;

    2006-01-01

    The aim of the study presented here was to evaluate the use of PCR for improving the diagnosis of Toxoplasma gondii infection in immunocompromised hosts. Three hundred thirty-two bronchoalveolar lavage (BAL) fluid samples were analyzed by real-time PCR targeting a 529 bp element of T. gondii...... be performed in all immunosuppressed HIV-positive patients with symptoms of a systemic infection of unknown etiology. Trimethoprim-sulfamethoxazole prophylaxis does not exclude concomitant infection with T. gondii....

  19. Improved Serotype-Specific Dengue Virus Detection in Trinidad and Tobago using a Multiplex, Real-Time RT-PCR

    Science.gov (United States)

    Waggoner, Jesse J.; Sahadeo, Nikita S. D.; Brown, Arianne; Mohamed-Hadley, Alisha; Hadley, Dexter; Carrington, Leslie; Carrington, Christine V. F.; Pinsky, Benjamin A.

    2014-01-01

    Dengue virus (DENV) transmission occurs throughout the Caribbean, though laboratory confirmation and epidemiologic surveillance is limited by the availability of serotype-specific molecular diagnostics. In this study, we show that a serotype-specific DENV multiplex, real-time RT-PCR detected DENV RNA in significantly more samples (82/182) than a reference hemi-nested RT-PCR (57/182; p=0.01). PMID:25533614

  20. Optimization of the Sybr Green real time PCR for the detection of Human Herpes Virus type 6 (HHV-6).

    Science.gov (United States)

    Canto, Cynthia Liliane Motta do; Sumita, Laura Massami; Machado, Adriana Freire; Tateno, Adriana; Cunha, Eveline Vieira da; Machado, Clarisse Martins

    2008-01-01

    HHV-6 is the etiological agent of Exanthem subitum which is considered the sixth most frequent disease in infancy. In immuno-compromised hosts, reactivation of latent HHV-6 infection may cause severe acute disease. We developed a Sybr Green Real Time PCR for HHV-6 and compared the results with nested conventional PCR. A 214 pb PCR derived fragment was cloned using pGEM-T easy from Promega system. Subsequently, serial dilutions were made in a pool of negative leucocytes from 10-6 ng/microL (equivalent to 2465.8 molecules/microL) to 10-9 (equivalent to 2.46 molecules/microL). Dilutions of the plasmid were amplified by Sybr Green Real Time PCR, using primers HHV3 (5' TTG TGC GGG TCC GTT CCC ATC ATA 3)'and HHV4 (5' TCG GGA TAG AAA AAC CTA ATC CCT 3') and by conventional nested PCR using primers HHV1 (outer): 5'CAA TGC TTT TCT AGC CGC CTC TTC 3'; HHV2 (outer): 5' ACA TCT ATA ATT TTA GAC GAT CCC 3'; HHV3 (inner) and HHV4 (inner) 3'. The detection threshold was determined by plasmid serial dilutions. Threshold for Sybr Green real time PCR was 24.6 molecules/microL and for the nested PCR was 2.46 molecules/microL. We chose the Real Time PCR for diagnosing and quantifying HHV-6 DNA from samples using the new Sybr Green chemistry due to its sensitivity and lower risk of contamination.

  1. Comparison of Real-Time PCR and Culture for Detection of Porphyromonas gingivalis in Subgingival Plaque Samples

    OpenAIRE

    Boutaga, Khalil; van Winkelhoff, Arie Jan; Vandenbroucke-Grauls, Christina M. J. E.; Savelkoul, Paul H. M.

    2003-01-01

    Porphyromonas gingivalis is a major pathogen in destructive periodontal disease in humans. Detection and quantification of this microorganism are relevant for diagnosis and treatment planning. The prevalence and quantity of P. gingivalis in subgingival plaque samples of periodontitis patients were determined by anaerobic culture and real-time PCR amplification of the 16S small-subunit rRNA gene. The PCR was performed with primers and a fluorescently labeled probe specific for the P. gingivali...

  2. Evaluation of inhibitor-resistant real-time PCR methods for diagnostics in clinical and environmental samples.

    Directory of Open Access Journals (Sweden)

    Adrienne Trombley Hall

    Full Text Available Polymerase chain reaction (PCR is commonly used for pathogen detection in clinical and environmental samples. These sample matrices often contain inhibitors of PCR, which is a primary reason for sample processing; however, the purification process is highly inefficient, becoming unacceptable at lower signature concentrations. One potential solution is direct PCR assessment without sample processing. Here, we evaluated nine inhibitor-resistant PCR reagents for direct detection of Francisella tularensis in seven different clinical and environmental samples using an established real-time PCR assay to assess ability to overcome PCR inhibition. While several of these reagents were designed for standard PCR, the described inhibitor resistant properties (ex. Omni Klentaq can amplify target DNA samples of up to 20% whole blood or soil led to our evaluation with real-time PCR. A preliminary limit of detection (LOD was determined for each chemistry in whole blood and buffer, and LODs (20 replicates were determined for the top five chemistries in each matrix (buffer, whole blood, sputum, stool, swab, soil, and sand. Not surprisingly, no single chemistry performed the best across all of the different matrices evaluated. For instance, Phusion Blood Direct PCR Kit, Phire Hot Start DNA polymerase, and Phire Hot Start DNA polymerase with STR Boost performed best for direct detection in whole blood while Phire Hot Start DNA polymerase with STR Boost were the only reagents to yield an LOD in the femtogram range for soil. Although not the best performer across all matrices, KAPA Blood PCR kit produced the most consistent results among the various conditions assessed. Overall, while these inhibitor resistant reagents show promise for direct amplification of complex samples by real-time PCR, the amount of template required for detection would not be in a clinically relevant range for most matrices.

  3. The development and application of the two real-time RT-PCR assays to detect the pathogen of HFMD.

    Directory of Open Access Journals (Sweden)

    Aili Cui

    Full Text Available Large-scale Hand, Foot, and Mouth Disease (HFMD outbreaks have frequently occurred in China since 2008, affecting more than one million children and causing several hundred children deaths every year. The pathogens of HFMD are mainly human enteroviruses (HEVs. Among them, human enterovirus 71 (HEV71 and coxsackievirus A16 (CVA16 are the most common pathogens of HFMD. However, other HEVs could also cause HFMD. To rapidly detect HEV71 and CVA16, and ensure detection of all HEVs causing HFMD, two real-time hybridization probe-based RT-PCR assays were developed in this study. One is a multiplex real-time RT-PCR assay, which was developed to detect and differentiate HEV71 specifically from CVA16 directly from clinical specimens within 1-2 h, and the other is a broad-spectrum real-time RT-PCR assay, which targeted almost all HEVs. The experiments confirmed that the two assays have high sensitivity and specificity, and the sensitivity was up to 0.1 TCID50/ml for detection of HEVs, HEV71, and CVA16, respectively. A total of 213 clinical specimens were simultaneously detected by three kinds of assays, including the two real-time RT-PCR assays, direct conventional RT-PCR assay, and virus isolation assay on human rhabdomyosarcoma cells (RD cells. The total positive rate of both HEV71 and CVA16 was 69.48% with real-time RT-PCR assay, 47.42% with RT-PCR assay, and 34.58% with virus isolation assay. One HFMD clinical specimen was positive for HEV, but negative for HEV71 or CVA16, which was identified as Echovirus 11 (Echo11 by virus isolation, RT-PCR, and sequencing for the VP1 gene. The two real-time RT-PCR assays had been applied in 31 provincial HFMD labs to detect the pathogens of HFMD, which has contributed to the rapid identification of the pathogens in the early stages of HFMD outbreaks, and helped to clarify the etiologic agents of HFMD in China.

  4. Assessing HER2 amplification by IHC, FISH, and real-time polymerase chain reaction analysis (real-time PCR) following LCM in formalin-fixed paraffin embedded tissue from 40 women with ovarian cancer.

    Science.gov (United States)

    Hillig, Thore; Thode, Jørgen; Breinholt, Marie F; Franzmann, Maria-Benedicte; Pedersen, Carsten; Lund, Flemming; Mygind, Henrik; Sölétormos, György; Rudnicki, Martin

    2012-12-01

    We compare HER2 receptor amplification analysis by immunohistochemistry (IHC), fluorescence in situ hybridization (FISH), and real-time polymerase chain reaction (real-time PCR) DNA copy-number assay following laser capture microdissection (LCM) in formalin-fixed paraffin embedded tissue from 40 women with verified ovarian cancer. We speculate that LCM should result in a more accurate assessment of HER2 amplification in our real-time PCR assay compared with IHC and FISH. HER2 overexpression measured by IHC, FISH, or real-time PCR was found in 5.0%, 5.0%, and 22.5%, respectively. HER2 negative results measured by IHC, FISH, or real-time PCR were found in 95%, 92.5%, and 60.0%, respectively. Analysis failed for IHC, FISH, or real-time PCR in 0%, 2.5%, or 17.5% of cases. Concordance between IHC and FISH, IHC and real-time PCR, or FISH and real-time PCR were 89.7%, 72.7%, or 78.1%, respectively. Only few ovarian cancer patients were HER2 overexpressed measured by IHC or FISH and thus could be eligible for antibody-based therapy with trastuzumab (Herceptin). Interestingly, we find an increased number of HER2 positive patients by real-time PCR analysis on microdissected cancer cells, suggesting a number of HER2 positive patients not detected by current methods. Thus, the concept of quantitative measurement of HER2 on microdissected cancer cells should be explored further. © 2012 The Authors APMIS © 2012 APMIS.

  5. Duplex real-time PCR for detection and quantification of monodon baculovirus (MBV) and hepatopancreatic parvovirus (HPV) in Penaeus monodon.

    Science.gov (United States)

    Tang, Kathy F J; Lightner, Donald V

    2011-02-22

    We describe a duplex real-time PCR assay using TaqMan probes for the simultaneous detection of monodon baculovirus (MBV) and hepatopancreatic parvovirus (HPV). Both MBV and HPV are shrimp enteric viruses that infect intestinal and hepatopancreatic epithelial cells. Both viruses can cause significant mortalities and depressed growth in infected larval, postlarval, and early juvenile stages of shrimp, and thus present a risk to commercial aquaculture. In this duplex assay, we combined 2 single real-time PCRs, amplifying MBV and HPV, in a one-tube PCR reaction. The 2 viruses were distinguished by specific fluorescent labels at the 5' end of TaqMan probes: the MBV probe was labeled with dichlorodimethoxyfluorescein (JOE), and the HPV probe was labeled with 6-carboxyfluorescein (FAM). The duplex real-time PCR assay was performed in a multi-channel real-time PCR detection system, and MBV and HPV amplification signals were separately detected by the JOE and FAM channels. This duplex assay was validated to be specific to the target viruses and found to have a detection limit of single copies for each virus. The dynamic range was found to be from 1 to 1 x 10(8) copies per reaction. This assay was further applied to quantify MBV and HPV in samples of infected Penaeus monodon collected from Malaysia, Indonesia, and Thailand. The specificity and sensitivity of this duplex real-time PCR assay offer a valuable tool for routine diagnosis and quantification of MBV and HPV from both wild and farmed shrimp stocks.

  6. Real-time PCR strategy for parasite quantification in blood and tissue samples of experimental Trypanosoma cruzi infection.

    Science.gov (United States)

    Caldas, Sérgio; Caldas, Ivo Santana; Diniz, Lívia de Figueiredo; Lima, Wanderson Geraldo de; Oliveira, Riva de Paula; Cecílio, Alzira Batista; Ribeiro, Isabela; Talvani, André; Bahia, Maria Terezinha

    2012-09-01

    The lack of an accurate diagnosis has been a serious obstacle to the advancement of the anti-Trypanosoma cruzi chemotherapy and long-term infection can result in different health risks to human. PCRs are alternative methods, more sensitive than conventional parasitological techniques, which due to their low sensitivities are considered unsuitable for these purposes. The aim of this study was to investigate a sensitive diagnostic strategy to quantify blood and cardiac tissues parasites based on real-time PCR tools during acute and chronic phases of murine Chagas disease, as well as to monitor the evolution of infection in those mice under specific treatment. In parallel, fresh blood examination, immunological analysis and quantification of cardiac inflammation were also performed to confront and improve real-time PCR data. Similar profiles of parasitemia curves were observed in both quantification techniques during the acute phase of the infection. In contrast, parasites could be quantified only by real-time PCR at 60 and 120 days of infection. In cardiac tissue, real-time PCR detected T. cruzi DNA in 100% of infected mice, and using this tool a significant Pearson correlation between parasite load in peripheral blood and in cardiac tissue during acute and chronic phases was observed. Levels of serum CCL2, CCL5 and nitric oxide were coincident with parasite load but focal and diffuse mononuclear infiltrates was observed, even with significant (pblood and cardiac muscle at the treatment period, but after the end of chemotherapy an increase of parasitism was detected. Interestingly, inflammatory mediators levels and heart inflammation intensity had similar evolution to the parasite load, in the group of animals treated. Taken together, our data show that real-time PCR strategy used was suitable for studies of murine T. cruzi infection and may prove useful in investigations involving experimental chemotherapy of the disease and the benefits of treatment in relation to

  7. 实时荧光定量PCR技术在食源性致病菌检测中的应用%Application of Real-time Fluorescent Quantitative PCR for the Detection of Food-borne Pathogenic Bacteria

    Institute of Scientific and Technical Information of China (English)

    吕艳芳; 马春颖; 励建荣

    2014-01-01

    近年来食源性疾病爆发数量呈上升趋势,食品安全问题已经成为危害人们生命和健康的严重问题,引起了全世界消费者对食品品质、安全和卫生的关注。实时荧光定量PCR技术是在定性PCR技术的基础上发展起来的核酸定量技术,灵敏性高、特异性强,实现了对DNA模板的定量检测,目前已广泛应用于食品检测领域。本文概述了实时荧光定量PCR技术的原理及其在食源性致病菌检测中的应用,并对其应用前景进行了探讨。%The outbreak of food-borne disease has shown a rising trend in recent years, and the problem of food safety seriously threats people’s life and health. Consumers around the world pay much attention to food quality, safety and health. Real-time fluorescent quantitative PCR technique is a nucleic acid quantitative technique, on the basis of the qualitative PCR technology, having high sensitivity, strong specificity, which has realized the quantita-tive detection of DNA template, and now has been widely used in the field of food detection. This paper summa-rized the principle of real-time fluorescent quantitative PCR technique and its application in the detection of food-borne pathogenic bacteria, and discussed the application prospect.

  8. Development and comparison of a real-time PCR assay for detection of Dichelobacter nodosus with culturing and conventional PCR: harmonisation between three laboratories

    DEFF Research Database (Denmark)

    Frosth, Sara; Slettemeås, Jannice S.; Jørgensen, Hannah J.

    2012-01-01

    BACKGROUND: Ovine footrot is a contagious disease with worldwide occurrence in sheep. The main causative agent is the fastidious bacterium Dichelobacter nodosus. In Scandinavia, footrot was first diagnosed in Sweden in 2004 and later also in Norway and Denmark. Clinical examination of sheep feet...... a TaqMan-based real-time PCR assay for detection of D. nodosus and to compare its performance with culturing and conventional PCR. METHODS: A D. nodosus-specific TaqMan based real-time PCR assay targeting the 16S rRNA gene was designed. The inclusivity and exclusivity (specificity) of the assay...... was tested using 55 bacterial and two fungal strains. To evaluate the sensitivity and harmonisation of results between different laboratories, aliquots of a single DNA preparation were analysed at three Scandinavian laboratories. The developed real-time PCR assay was compared to culturing by analysing 126...

  9. Evaluation of internal control for gene expression in Phalaenopsis by quantitative real-time PCR.

    Science.gov (United States)

    Yuan, Xiu-Yun; Jiang, Su-Hua; Wang, Mo-Fei; Ma, Jie; Zhang, Xian-Yun; Cui, Bo

    2014-07-01

    The selection of appropriate reference genes is one of the most important steps to obtain reliable results for normalizing quantitative real-time reverse transcriptase polymerase chain reaction (qRT-PCR) of MADS-box gene in Phalaenopsis. In this study, we cloned 12 candidate reference genes including 18S ribosomal RNA (18S), elongation factor 1 alpha (EF1α), cytoskeletal structural protein actin (ACT1, ACT2, ACT3, ACT4, ACT5), ubiquitin protein (UBQ1 and UBQ2), glyceraldehyde-3-phosphate dehydrogenase (GAPDH), and the cytoskeletal structural proteins α-tubulin (TUA) and β-tubulin (TUB) in Phalaenopsis and evaluated their expression reliability. The expression of these candidate reference genes was analyzed using geNorm and normFinder software packages; the results showed that ACT2 and ACT4 were the highest stability reference genes for all experiment sets based on normFinder, followed by ACT1 or ACT3, while ACT3 and ACT4 were the highest stability reference genes for most experiment sets based on geNorm, then TUB or others. Taken together, Actin genes were the higher stability reference genes for all tissues at total developmental stages, and similar results came from analysis by normFinder. According to geNorm analysis, ACT3 and ACT4 were the most stable reference genes for all tissues tested and tissues at reproductive stages; TUB and ACT5 or ACT4 were the most stable reference genes for vegetative tissues or roots. The most stable reference genes for all vegetative tissues and only leaves were ACT4 and ACT5, ACT2 and ACT3, respectively; ACT1 and ACT3 were the most stable genes and sufficient for reliable normalization of flower tissues. While EF1α, UBQ1, UBQ2, and GAPDH were found to be unsuitable as a reference gene in our analysis for flower tissues, total tissues, and reproductive stages; UBQ2 and 18S were identified as the least stable reference genes for vegetative tissues at different stages, different tissues at vegetative stages; TUA and 18S were the

  10. Development of a new real-time PCR system for simultaneous detection of bacteria and fungi in pathological samples

    OpenAIRE

    2015-01-01

    A novel system for simultaneous detection of pathogenic bacteria and fungi in pathological samples was developed using a real-time polymerase chain reaction (PCR) system. This system, designated the “multi-microbial real-time PCR”, has the potential to simultaneously detect 68 bacterial and 9 fungal species in a 96-well plate format. All probe-primer sets were designed to produce amplicons smaller than 210 bp using formalin-fixed paraffin-embedded samples as input. The specificity and sensiti...

  11. Real time polymerase chain reaction (rt-pcr for mycobacterium tuberculosis in serpiginous choroiditis- A study of 29 cases

    Directory of Open Access Journals (Sweden)

    RadhaAnnamalai, Jyotirmay Biswas, Sudharshan S, Gayathri R, Lily Therese, Viswanathan S, NamithaBhuvaneswari

    2014-07-01

    Full Text Available Purpose: A study of real time Polymerase Chain Reaction for Mycobacterium tuberculosis (M. tuberculosis DNA in 29 cases of active serpiginous choroiditis. Design: Case control study. Methods: DNA extraction from the aqueous humor was carried out using QIAMP DNA extraction kit. Real- time Polymerase Chain reaction (RT-PCR for MTB was carried out using Genosen’s Mtb complex quantitative Real time PCR kit. All patients were also subjected to complete blood count, venereal disease research laboratory test, chest radiograph, QuantiFERON TB Gold test on the blood and polymerase chain reaction on a sample of aqueous humor. Results: Aqueous aspirate showed copies of mycobacterium tuberculosis DNA in one out of twenty nine cases of serpiginous choroiditis. Direct smear and culture for mycobacteria was negative in all cases. Conclusion: RT-PCR identifies MTB DNA in suspected latent tuberculosis in serpiginous choroiditis with high specificity. Serpiginous choroiditis and multifocal choroiditis due to tuberculosis may resemble each other clinically but have distinct clinical features which can be confirmed by real time polymerase chain reaction performed on the aqueous humor The association between serpiginous choroiditis and tuberculosis would be a chance association or if present a rare association.

  12. MeDIP Real-Time qPCR has the Potential for Noninvasive Prenatal Screening of Fetal Trisomy 21.

    Science.gov (United States)

    Kazemi, Mohammad; Salehi, Mansoor; Kheirollahi, Majid

    2017-01-01

    This study aimed to verify the reliability of the 7 tissue differentially methylated regions used in the methylated DNA immunoprecipitation (MeDIP) real- time quantitative polymerase chain reaction (real-time qPCR) based approach of fetal DNA in maternal blood to diagnosis of fetal trisomy 21. Forty pregnant women with high risk pregnancy who were referred after first or second trimester screening tests, were selected randomly. For each sample whole DNA extraction (mother and fetus), fragmentation of DNA, immunoprecipitation of methylated DNA and real- time qPCR using 7 primer pairs was performed. D-value for each sample was calculated using the following formula D = -4.908+ 0.254 XEP1+ 0.409 XEP4+ 0.793 XEP5+ 0.324 XEP6+ 0.505 XEP7+ 0.508 XEP9+ 0.691 XEP12. In all normal cases, D value was negative, while it was positive in all trisomy cases. Therefore, all normal and trisomy 21 cases were classified correctly which correspond to 100% specificity and 100% sensitivity for this method. The MeDIP real-time qPCR method has provided the opportunity for noninvasive prenatal diagnosis of fetal trisomy 21 to be potentially employed into the routine practice of diagnostic laboratories.

  13. Evaluation of a new real-time PCR assay for the direct detection of diarrheagenic Escherichia coli in stool specimens.

    Science.gov (United States)

    Eigner, U; Hiergeist, A; Veldenzer, A; Rohlfs, M; Schwarz, R; Holfelder, M

    2017-02-01

    Diarrheagenic E. coli (DEC) are one of the most common causes for diarrhea worldwide, especially in children. We evaluated the rapid RIDA ® GENE (RG) real-time multiplex PCR assays (R-Biopharm, Darmstadt, Germany) for the detection of the most important diarrheagenic E. coli. Three hundred fifteen liquid or non-formed stool specimens were examined. The results of the RG multiplex assays were compared to specific PCR methods. The sensitivity and specificity of the RG PCRs were as follows, 100%/100% for the detection of EHEC, 96.3% and 99% for EPEC, 100% and 100% for the detection of EAEC, ETEC and EIEC, respectively. Overall, the RG real-time PCR system for the detection of DEC tested in this study provided reliable and rapid results and shows the ability as a useful addendum for the detection of diarrheagenic E. coli in the medical laboratory.

  14. [Real-time PCR detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae DNA in clinical specimens].

    Science.gov (United States)

    Vacková, Z; Lžičařová, D; Stock, N K; Kozáková, J

    2015-10-01

    The study aim was to implement a molecular real-time polymerase chain reaction (PCR) assay recommended by the CDC (Centers for Disease Control and Prevention) for the detection of Neisseria meningitidis, Haemophilus influenzae, and Streptococcus pneumoniae in clinical (culture negative) specimens from patients with suspected invasive bacterial disease. Clinical specimens are referred to the National Reference Laboratory (NRL) for Meningococcal Infections, Unit for Airborne Bacterial Infections, Centre for Epidemiology and Microbiology, National Institute of Public Health from various regions of the Czech Republic. Clinical specimens are, in particular, cerebrospinal fluid, anti-coagulated blood or serum and, exceptionally, post-mortem specimens. The NRL has implemented molecular diagnosis of these bacterial pathogens involved in meningitis and sepsis from clinical specimens since 1999. The first diagnostic method was semi-nested PCR followed by electrophoretic analysis. In 2014, a molecular qualitative real-time PCR assay was implemented.

  15. Simulation of collaborative studies for real-time PCR-based quantitation methods for genetically modified crops.

    Science.gov (United States)

    Watanabe, Satoshi; Sawada, Hiroshi; Naito, Shigehiro; Akiyama, Hiroshi; Teshima, Reiko; Furui, Satoshi; Kitta, Kazumi; Hino, Akihiro

    2013-01-01

    To study impacts of various random effects and parameters of collaborative studies on the precision of quantitation methods of genetically modified (GM) crops, we developed a set of random effects models for cycle time values of a standard curve-based relative real-time PCR that makes use of an endogenous gene sequence as the internal standard. The models and data from a published collaborative study for six GM lines at four concentration levels were used to simulate collaborative studies under various conditions. Results suggested that by reducing the numbers of well replications from three to two, and standard levels of endogenous sequence from five to three, the number of unknown samples analyzable on a 96-well PCR plate in routine analyses could be almost doubled, and still the acceptable repeatability RSD (RSDr crops by real-time PCR and their collaborative studies.

  16. On-chip single-copy real-time reverse-transcription PCR in isolated picoliter droplets

    Energy Technology Data Exchange (ETDEWEB)

    Beer, N R; Wheeler, E; Lee-Houghton, L; Watkins, N; Nasarabadi, S; Hebert, N; Leung, P; Arnold, D; Bailey, C; Colston, B

    2007-12-19

    The first lab-on-chip system for picoliter droplet generation and RNA isolation, followed by reverse transcription, and PCR amplification with real-time fluorescence detection in the trapped droplets has been developed. The system utilized a shearing T-junction in a fused silica device to generate a stream of monodisperse picoliter-scale droplets that were isolated from the microfluidic channel walls and each other by the oil phase carrier. An off-chip valving system stopped the droplets on-chip, allowing thermal cycling for reverse transcription and subsequent PCR amplification without droplet motion. This combination of the established real-time reverse transcription-PCR assay with digital microfluidics is ideal for isolating single-copy RNA and virions from a complex environment, and will be useful in viral discovery and gene-profiling applications.

  17. Comparison of two real-time PCR assays for the detection of malaria parasites from hemolytic blood samples - Short communication.

    Science.gov (United States)

    Hagen, Ralf Matthias; Hinz, Rebecca; Tannich, Egbert; Frickmann, Hagen

    2015-06-01

    We compared the performance of an in-house and a commercial malaria polymerase chain reaction (PCR) assay using freeze-thawed hemolytic blood samples. A total of 116 freeze-thawed ethylenediamine tetraacetic acid (EDTA) blood samples of patients with suspicion of malaria were analyzed by an in-house as well as by a commercially available real-time PCR. Concordant malaria negative PCR results were reported for 39 samples and malaria-positive PCR results for 67 samples. The in-house assay further detected one case of Plasmodium falciparum infection, which was negative in the commercial assay as well as five cases of P. falciparum malaria and three cases of Plasmodium vivax malaria, which showed sample inhibition in the commercial assay. The commercial malaria assay was positive in spite of a negative in-house PCR result in one case. In all concordant results, cycle threshold values of P. falciparum-positive samples were lower in the commercial PCR than in the in-house assay. Although Ct values of the commercial PCR kit suggest higher sensitivity in case of concordant results, it is prone to inhibition if it is applied to hemolytic freeze-thawed blood samples. The number of misidentifications was, however, identical for both real-time PCR assays.

  18. Molecular diagnosis of African Swine Fever by a new real-time PCR using universal probe library.

    Science.gov (United States)

    Fernández-Pinero, J; Gallardo, C; Elizalde, M; Robles, A; Gómez, C; Bishop, R; Heath, L; Couacy-Hymann, E; Fasina, F O; Pelayo, V; Soler, A; Arias, M

    2013-02-01

    A highly sensitive and specific real-time PCR method was developed for the reliable and rapid detection of African swine fever virus (ASFV). The method uses a commercial Universal Probe Library (UPL) probe combined with a specifically designed primer set to amplify an ASFV DNA fragment within the VP72 coding genome region. The detection range of the optimized UPL PCR technique was confirmed by analysis of a large panel (n = 46) of ASFV isolates, belonging to 19 of the 22 viral p72 genotypes described. No amplification signal was observed when closely clinically related viruses, such as classical swine fever, or other porcine pathogens were tested by this assay. The detection limit of the UPL PCR method was established below 18 DNA copies. Validation experiments using an extensive collection of field porcine and tick samples (n = 260), coming from Eastern and Western African regions affected by ASF, demonstrated that the UPL PCR technique was able to detect over 10% more positive samples than the real-time TaqMan PCR test recommended in the OIE manual, confirming its superior diagnostic sensitivity. Clinical material collected during experimental infections with different ASFV p72 genotypes was useful for assuring both the capacity of the UPL PCR for an early viral DNA detection and the competence of the technique to be applied in any ASF diagnostic target sample. The reliability and robustness of the UPL PCR was finally verified with a panel of ASFV-infected clinical samples which was repeatedly tested at different times. Additionally, an internal control PCR assay was also developed and standardized using UPL probes within the endogenous β-actin gene. Finally, the complete study offers a new validated real-time PCR technique, by means of a standardized commercial probe, providing a simple, rapid and affordable test, which is ready for application in the routine diagnosis of ASF.

  19. Canine visceral leishmaniasis: a comparative study of real-time PCR, conventional PCR, and direct agglutination on sera for the detection of Leishmania infantum infection.

    Science.gov (United States)

    Mohammadiha, A; Haghighi, A; Mohebali, M; Mahdian, R; Abadi, A R; Zarei, Z; Yeganeh, F; Kazemi, B; Taghipour, N; Akhoundi, B; Barati, M; Mahmoudi, M R

    2013-02-18

    Canine visceral leishmaniasis (CVL) is endemic in northwestern Iran. This study aimed to compare real-time PCR, conventional PCR, and the direct agglutination test (DAT) for the diagnosis Leishmania infantum infection in 167 serum samples of domestic dog. Bone marrow was used for parasitological examination (smears and/or culture) in symptomatic visceral leishmaniasis, and serum was used for detection of L. infantum kinetoplast DNA (kDNA) by both conventional PCR and real-time PCR, while anti-L. infantum antibodies in sera were measured by DAT. The sera were collected from 37 symptomatic and 112 asymptomatic dogs during April to May 2011. Eighteen presumed negative samples were obtained from healthy dogs kept in non-endemic areas with no history of CVL and used as controls. All 18 samples were negative by DAT and Dipstick rK39. DAT confirmed previous exposure to L. infantum for all 149 serum samples collected from symptomatic and asymptomatic dogs in CVL endemic areas of Iran. Among the 37 symptomatic dogs, 20 (54%), 25 (67.6%), 36 (97.3%), and 37 (100%) showed L. infantum infection by parasitological methods, conventional PCR, real-time PCR, and DAT (≥ 1:80), respectively. Of 112 asymptomatic dogs, 79 (70.5%), 111 (99.1%), and 112 (100%) were shown to be positive by conventional PCR, and DAT (≥ 1:80), respectively. For ethical reasons, no asymptomatic or healthy control dogs were examined by parasitological methods. Three (16.7%) control dogs were positive by real-time PCR, but were negative by DAT, dipstick rK39, and conventional PCR methods. Parasitemia levels were measured by real-time PCR targeting kDNA using SYBR(®) green assay. This quantitative technique detected infection in 89.9% (150/167) of the domestic dogs that harbored L. infantum kDNA, ranging from 0.01 49 to 310.1 parasites/ml. The average was 16.60 parasites/ml. A good agreement (0.97) was found between real-time PCR and DAT at ≥ 1:80 titer, used as cut-off value by Kappa analysis. Thus

  20. Real-time PCR using SYBR Green for the detection of Shigella spp. in food and stool samples.

    Science.gov (United States)

    Mokhtari, W; Nsaibia, S; Gharbi, A; Aouni, M

    2013-02-01

    Shigella spp are exquisitely fastidious Gram negative organisms that frequently get missed in the detection by traditional culture methods. For this reason, this work has adapted a classical PCR for detection of Shigella in food and stool specimens to real-time PCR using the SYBR Green format. This method follows a melting curve analysis to be more rapid and provide both qualitative and quantitative data about the targeted pathogen. A total of 117 stool samples with diarrhea and 102 food samples were analyzed in Public Health Regional Laboratory of Nabeul by traditional culture methods and real-time PCR. To validate the real-time PCR assay, an experiment was conducted with both spiked and naturally contaminated stool samples. All Shigella strains tested were ipaH positive and all non-Shigella strains yielded no amplification products. The melting temperature (T(m) = 81.5 ± 0.5 °C) was consistently specific for the amplicon. Correlation coefficients of standard curves constructed using the quantification cycle (C(q)) versus copy numbers of Shigella showed good linearity (R² = 0.995; slope = 2.952) and the minimum level of detection was 1.5 × 10³ CFU/g feces. All food samples analyzed were negative for Shigella by standard culture methods, whereas ipaH was detected in 8.8% culture negative food products. Moreover, the ipaH specific PCR system increased the detection rate over that by culture alone from 1.7% to 11.1% among patients with diarrhea. The data presented here shows that the SYBR Green I was suitable for use in the real-time PCR assay, which provided a specific, sensitive and efficient method for the detection and quantification of Shigella spp in food and stool samples.