WorldWideScience

Sample records for quality control techniques

  1. TECHNIQUES ABOUT DIRECT OPTIMIZING CONTROL OF GREEN SAND QUALITY*

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    Green sand casting is still a main method in the world at present and it is very significant to develop the technology of controlling green sand quality. A new concept, from contents test to contents control, is advanced. In order to realize the new idea, a new method to on-line test active clay and moisture of green sand - double powers energizing alternately (DPEA) method is put forwards. The principle of the new method is to energize standard sand sample with AC and DC powers and to test the electric parameters, and then, to calculate active clay and moisture of green sand by using artificial neural network (ANN). Based on this new method, a direct optimizing system for controlling green sand quality is developed. Techniques about testing and controlling methods, hardware and software are discussed.

  2. Antimisting kerosene: Base fuel effects, blending and quality control techniques

    Science.gov (United States)

    Yavrouian, A. H.; Ernest, J.; Sarohia, V.

    1984-01-01

    The problems associated with blending of the AMK additive with Jet A, and the base fuel effects on AMK properties are addressed. The results from the evaluation of some of the quality control techniques for AMK are presented. The principal conclusions of this investigation are: significant compositional differences for base fuel (Jet A) within the ASTM specification DI655; higher aromatic content of the base fuel was found to be beneficial for the polymer dissolution at ambient (20 C) temperature; using static mixer technology, the antimisting additive (FM-9) is in-line blended with Jet A, producing AMK which has adequate fire-protection properties 15 to 20 minutes after blending; degradability of freshly blended and equilibrated AMK indicated that maximum degradability is reached after adequate fire protection is obtained; the results of AMK degradability as measured by filter ratio, confirmed previous RAE data that power requirements to decade freshly blended AMK are significantly higher than equilibrated AMK; blending of the additive by using FM-9 concentrate in Jet A produces equilibrated AMK almost instantly; nephelometry offers a simple continuous monitoring capability and is used as a real time quality control device for AMK; and trajectory (jet thurst) and pressure drop tests are useful laboratory techniques for evaluating AMK quality.

  3. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors cau...

  4. Analytical techniques and quality control in biomedical trace element research

    DEFF Research Database (Denmark)

    Heydorn, K.

    1994-01-01

    The small number of analytical results in trace element research calls for special methods of quality control. It is shown that when the analytical methods are in statistical control, only small numbers of duplicate or replicate results are needed to ascertain the absence of systematic errors cau....../kg. Measurement compatibility is obtained by control of traceability to certified reference materials, (C) 1994 Wiley-Liss, Inc....

  5. 78 FR 34306 - Approval and Promulgation of Air Quality Implementation Plans: North Carolina; Control Techniques...

    Science.gov (United States)

    2013-06-07

    ... nonattainment area. List of Subjects in 40 CFR Part 52 Environmental protection, Air pollution control... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans: North Carolina; Control Techniques Guidelines and Reasonably Available Control Technology AGENCY: Environmental...

  6. HPLC-MS technique for radiopharmaceuticals analysis and quality control

    Science.gov (United States)

    Macášek, F.; Búriová, E.; Brúder, P.; Vera-Ruiz, H.

    2003-01-01

    Potentialities of liquid chromatography with mass spectrometric detector (MSD) were investigated with the objective of quality control of radiopharmaceuticals; 2-deoxy-2-[18F]fluoro-D-glucose (FDG) being an example. Screening of suitable MSD analytical lines is presented. Mass-spectrometric monitoring of acetonitrile— aqueous ammonium formate eluant by negatively charged FDG.HCO2 - ions enables isotope analysis (specific activity) of the radiopharmaceutical at m/z 227 and 226. Kryptofix® 222 provides an intense MSD signal of the positive ion associated with NH4 + at m/z 394. Expired FDG injection samples contain decomposition products from which at least one labelled by 18F and characterised by signal of negative ions at m/z 207 does not correspond to FDG fragments but to C5 decomposition products. A glucose chromatographic peak, characterised by m/z 225 negative ion is accompanied by a tail of a component giving a signal of m/z 227, which can belong to [18O]glucose; isobaric sorbitol signals were excluded but FDG-glucose association occurs in the co-elution of separation of model mixtures. The latter can actually lead to a convoluted chromatographic peak, but the absence of 18F makes this inconsistent. Quantification and validation of the FDG component analysis is under way.

  7. Electromagnetic techniques for industrial plant process measurements and quality control

    Energy Technology Data Exchange (ETDEWEB)

    Bramanti, M. (Consiglio Nazionale delle Ricerche, Pisa (Italy). Ist. di Elaborazione della Informazione)

    1992-04-01

    In recent years, new real time non-destructive measuring techniques have been developed based on the use of miniaturized components capable of generating, amplifying and elaborating microwave signals (within the range of tenths of a volt and hundreds of milliamps). All these techniques for the measurement of typical process parameters or the non-destructive testing of materials are based on the interaction of radiation with the material or system under examination and make use of the most modern types of data acquisition technology. This article surveys the sensors and measuring instruments which make use of electromagnetic radiation to acquire information concerning the properties of an examined material or system based on their interactions with electromagnetic fields. A few applications are illustrated, e.g., the measurement of unburnt coal in power plant fly ash, the measurement of the quantity of solid particles present in fluidized beds and the verification of the properties of dielectric materials. In each case, the optimum degree of resolution of these devices is made evident.

  8. A quality control technique based on UV-VIS absorption spectroscopy for tequila distillery factories

    Science.gov (United States)

    Barbosa Garcia, O.; Ramos Ortiz, G.; Maldonado, J. L.; Pichardo Molina, J.; Meneses Nava, M. A.; Landgrave, Enrique; Cervantes, M. J.

    2006-02-01

    A low cost technique based on the UV-VIS absorption spectroscopy is presented for the quality control of the spirit drink known as tequila. It is shown that such spectra offer enough information to discriminate a given spirit drink from a group of bottled commercial tequilas. The technique was applied to white tequilas. Contrary to the reference analytic methods, such as chromatography, for this technique neither special personal training nor sophisticated instrumentations is required. By using hand-held instrumentation this technique can be applied in situ during the production process.

  9. Closed vessel technique for assessment of ballistic characteristics in quality control of propellant manufacture

    Directory of Open Access Journals (Sweden)

    G. Siva Ramakrishnan

    1958-07-01

    Full Text Available "In order to assess the ballistic performance of a propellant it is necessary to measure its following characteristics: (aForce constant, (bvivacity, and (cshape. It is possible to determine (aand (bby the closed vessel technique which enables ballistic performance of the propellant in the gun to be estimated. It can be very usefully employed for quality control of propellant manufacture. As more and more experience is gained in the closed vessel technique these tests have several other possible practical applications such as those: (afor inspection of propellants, (bfor assessment of quality, (c to reduce proof in guns, and (dto check ballistics of a lot after long storage."

  10. MATLAB Simulation of UPQC for Power Quality Mitigation Using an Ant Colony Based Fuzzy Control Technique.

    Science.gov (United States)

    Kumarasabapathy, N; Manoharan, P S

    2015-01-01

    This paper proposes a fuzzy logic based new control scheme for the Unified Power Quality Conditioner (UPQC) for minimizing the voltage sag and total harmonic distortion in the distribution system consequently to improve the power quality. UPQC is a recent power electronic module which guarantees better power quality mitigation as it has both series-active and shunt-active power filters (APFs). The fuzzy logic controller has recently attracted a great deal of attention and possesses conceptually the quality of the simplicity by tackling complex systems with vagueness and ambiguity. In this research, the fuzzy logic controller is utilized for the generation of reference signal controlling the UPQC. To enable this, a systematic approach for creating the fuzzy membership functions is carried out by using an ant colony optimization technique for optimal fuzzy logic control. An exhaustive simulation study using the MATLAB/Simulink is carried out to investigate and demonstrate the performance of the proposed fuzzy logic controller and the simulation results are compared with the PI controller in terms of its performance in improving the power quality by minimizing the voltage sag and total harmonic distortion.

  11. MATLAB Simulation of UPQC for Power Quality Mitigation Using an Ant Colony Based Fuzzy Control Technique

    Science.gov (United States)

    Kumarasabapathy, N.; Manoharan, P. S.

    2015-01-01

    This paper proposes a fuzzy logic based new control scheme for the Unified Power Quality Conditioner (UPQC) for minimizing the voltage sag and total harmonic distortion in the distribution system consequently to improve the power quality. UPQC is a recent power electronic module which guarantees better power quality mitigation as it has both series-active and shunt-active power filters (APFs). The fuzzy logic controller has recently attracted a great deal of attention and possesses conceptually the quality of the simplicity by tackling complex systems with vagueness and ambiguity. In this research, the fuzzy logic controller is utilized for the generation of reference signal controlling the UPQC. To enable this, a systematic approach for creating the fuzzy membership functions is carried out by using an ant colony optimization technique for optimal fuzzy logic control. An exhaustive simulation study using the MATLAB/Simulink is carried out to investigate and demonstrate the performance of the proposed fuzzy logic controller and the simulation results are compared with the PI controller in terms of its performance in improving the power quality by minimizing the voltage sag and total harmonic distortion. PMID:26504895

  12. MATLAB Simulation of UPQC for Power Quality Mitigation Using an Ant Colony Based Fuzzy Control Technique

    Directory of Open Access Journals (Sweden)

    N. Kumarasabapathy

    2015-01-01

    Full Text Available This paper proposes a fuzzy logic based new control scheme for the Unified Power Quality Conditioner (UPQC for minimizing the voltage sag and total harmonic distortion in the distribution system consequently to improve the power quality. UPQC is a recent power electronic module which guarantees better power quality mitigation as it has both series-active and shunt-active power filters (APFs. The fuzzy logic controller has recently attracted a great deal of attention and possesses conceptually the quality of the simplicity by tackling complex systems with vagueness and ambiguity. In this research, the fuzzy logic controller is utilized for the generation of reference signal controlling the UPQC. To enable this, a systematic approach for creating the fuzzy membership functions is carried out by using an ant colony optimization technique for optimal fuzzy logic control. An exhaustive simulation study using the MATLAB/Simulink is carried out to investigate and demonstrate the performance of the proposed fuzzy logic controller and the simulation results are compared with the PI controller in terms of its performance in improving the power quality by minimizing the voltage sag and total harmonic distortion.

  13. Quality control of CML using EPID: cubic approximation technique; Control de calidad de CML usando EPID: tecnica de aproximacion cubica

    Energy Technology Data Exchange (ETDEWEB)

    Pino Leon, C.; Puertolas Hernandez, J. R.; Lozano Flores, F. J.; Larretxea Etxarri, R.

    2011-07-01

    In the implementation of IMRT in radiotherapy centers increasingly require more precise control of the linear accelerator quality. Specifically, the accuracy required in the quality control CML (multileaf collimator) over 0.5 mm 50n. In this sense, usually establishing in many centers using the technique of {sup g}arden fence{sup .} This image gives a 2 cm adjacent fields using EPID (Electronic Portal Image Device). In this paper we have developed a technique for automatic image analysis of EPID using ImageJ 1.43 thus increasing the accuracy and efficiency and removing the subjectivity of the analysis. (Author)

  14. Intraoperative Evaluation of Laparoscopic Insufflation Technique for Quality Control in the OR

    OpenAIRE

    Jacobs, Volker R.; Morrison, John E.; Mundhenke, Christoph; Golombeck, Kirstin; Jonat, Walter

    2000-01-01

    Objective: With increasing technology and computerized systems in the OR, the physician's responsibility is growing. For intraoperative evaluation of insufflation techniques, a data acquisition model for quality control study of potential insufflation problems is necessary. Methods: A computer-based, online data acquisition model was designed with a Pentium notebook, PCMCIA data acquisition board PCI-460-P1 and a Visual Designer 3.0 measurement program (both Intelligent Instrumentation, Inc.,...

  15. The utilization of six sigma and statistical process control techniques in surgical quality improvement.

    Science.gov (United States)

    Sedlack, Jeffrey D

    2010-01-01

    Surgeons have been slow to incorporate industrial reliability techniques. Process control methods were applied to surgeon waiting time between cases, and to length of stay (LOS) after colon surgery. Waiting times between surgeries were evaluated by auditing the operating room records of a single hospital over a 1-month period. The medical records of 628 patients undergoing colon surgery over a 5-year period were reviewed. The average surgeon wait time between cases was 53 min, and the busiest surgeon spent 291/2 hr in 1 month waiting between surgeries. Process control charting demonstrated poor overall control of the room turnover process. Average LOS after colon resection also demonstrated very poor control. Mean LOS was 10 days. Weibull's conditional analysis revealed a conditional LOS of 9.83 days. Serious process management problems were identified in both analyses. These process issues are both expensive and adversely affect the quality of service offered by the institution. Process control mechanisms were suggested or implemented to improve these surgical processes. Industrial reliability and quality management tools can easily and effectively identify process control problems that occur on surgical services.

  16. Evaluation of relationship of inhaler technique with asthma control and quality of life.

    Science.gov (United States)

    Chogtu, Bharti; Holla, Sadhana; Magazine, Rahul; Kamath, Asha

    2017-01-01

    There is a need to assess erroneous steps in the use of inhaler devices in people who have asthma. The objectives of this study were to assess the inhaler technique in patients who have asthma, the factors affecting improper technique, and the association of inhaler use with asthma control, hospital visits, and quality of life (QOL) of patients who have asthma. It was an observational, prospective, cross-sectional study conducted on patients with bronchial asthma. Patients were enrolled in the study; their history was recorded and they were asked to use inhaler in the presence of an investigator and the technique was scored. Asthma control and QOL of patients were assessed using asthma control questionnaire and Mini Asthma QOL questionnaire. A total of 330 patients completed the study. Nearly 36.6% of the patients performed the steps incorrectly. Breathing normally for 30-60 min postinhaler use was the most common step done incorrectly. Patients with poorly controlled asthma (P < 0.001) and those with predicted forced expiratory volume at 1 s <70% performed the steps erroneously (P < 0.001). All patients, particularly those above 40 years, should be given proper instructions regarding inhaler use to obtain therapeutic advantage.

  17. The evolution of tooling, techniques, and quality control for accelerator dipole magnet cables

    Energy Technology Data Exchange (ETDEWEB)

    Scanlan, R.M.

    1992-08-01

    The present generation of particle accelerators are utilizing the flattened, compacted, single layer cable design introduced nearly 20 years ago at Rutherford Laboratory. However, the requirements for current density, filament size, dimensional control long lengths, and low current degradation are much more stringent for the present accelerators compared with the earlier Tevatron and HERA accelerators. Also, in order to achieve higher field strengths with efficient use of superconductor, the new designs require wider cables with more strands. These requirements have stimulated an active research effort which has led to significant improvements in critical current density and conductor manufacturing. In addition they have stimulated the development of new cabling techniques, improved tooling, and better measurement techniques. The need to produce over 20 million meters of cable has led to the development of high speed cabling machines and on-line quality assurance measurements. These new developments will be discussed, and areas still requiring improvement will be identified.

  18. Quality control in hard disc drive manufacturing using pattern recognition technique

    Science.gov (United States)

    Masood, Ibrahim; Shyen, Victor Bee Ee

    2016-11-01

    Computerized monitoring-diagnosis is an efficient technique to identify the source of unnatural variation (UV) in manufacturing process. In this study, a pattern recognition scheme (PRS) for monitoring-diagnosis the UVs was developed based on control chart pattern recognition technique. This PRS integrates the multivariate exponentially weighted moving average (MEWMA) control chart and artificial neural network (ANN) recognizer to perform two-stage monitoring-diagnosis. The first stage monitoring was performed using the MEWMA statistics, whereas the second stage monitoring-diagnosis was performed using an ANN. The PRS was designed based on bivariate process mean shifts between 0.75σ and 3.00σ, with cross correlation between ρ=0.1 and 0.9. The performance of the proposed PRS has been validated in quality control of hard disk drive component manufacturing. The validation proved that it is efficient in rapidly detecting UV and accurately classify the source of UV patterns. In a nutshell, the PRS will aid in realizing automated decision making system in manufacturing industry.

  19. 78 FR 15895 - Approval and Promulgation of Air Quality Implementation Plans: North Carolina; Control Techniques...

    Science.gov (United States)

    2013-03-13

    ... 2D, .0521, .0614, NCAC 2Q .0102, .0304, and .0902. These rules address Air Pollution Control, Emission Control Standards, Monitoring and Recordkeeping and Air Quality Permit Procedures and are not... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans: North...

  20. Computed tomography: a powerful imaging technique in the fields of dimensional metrology and quality control

    Science.gov (United States)

    Probst, Gabriel; Boeckmans, Bart; Dewulf, Wim; Kruth, Jean-Pierre

    2016-05-01

    X-ray computed tomography (CT) is slowly conquering its space in the manufacturing industry for dimensional metrology and quality control purposes. The main advantage is its non-invasive and non-destructive character. Currently, CT is the only measurement technique that allows full 3D visualization of both inner and outer features of an object through a contactless probing system. Using hundreds of radiographs, acquired while rotating the object, a 3D representation is generated and dimensions can be verified. In this research, this non-contact technique was used for the inspection of assembled components. A dental cast model with 8 implants, connected by a screwed retained bar made of titanium. The retained bar includes a mating interface connection that should ensure a perfect fitting without residual stresses when the connection is fixed with screws. CT was used to inspect the mating interfaces between these two components. Gaps at the connections can lead to bacterial growth and potential inconvenience for the patient who would have to face a new surgery to replace his/hers prosthesis. With the aid of CT, flaws in the design or manufacturing process that could lead to gaps at the connections could be assessed.

  1. 75 FR 59084 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control Technique...

    Science.gov (United States)

    2010-09-27

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control...). ACTION: Direct final rule. SUMMARY: EPA is taking direct final action to approve a State Implementation Plan (SIP) revision submitted by the State of Maryland. This SIP revision pertains to the control...

  2. 77 FR 58953 - Approval and Promulgation of Air Quality Implementation Plans; Delaware; Control Technique...

    Science.gov (United States)

    2012-09-25

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Delaware; Control... published in the Federal Register. This action is not a ``major rule'' as defined by 5 U.S.C. 804(2). C... compounds. Dated: September 7, 2012. Shawn M. Garvin, Regional Administrator, Region III. 40 CFR part 52...

  3. TECHNIQUES OF 3D COMPONENT DATABASE ESTABLISHING AND QUALITY CONTROL FOR WOODEN BUILDING

    Institute of Scientific and Technical Information of China (English)

    2001-01-01

    Based on the architectural survey project of “the Chi Lin Nunnery Redevelopment "in Hong Kong,this paper attempts to investigate the techniques of building 3D digital document of large_scale timber structure and quality con trol during construction by computer_based 3D simulation for the whole project.T here were several key issues including primary data acquisition,3D modeling and display,pre_assembling the total building and quality examination,etc.In this pa per,some useful experiments,such as the new applications of CCD digital cameras,image and graph processing software packages (CAD,Photoshop,Photomod eler,Vexcel,etc.) to the architectures are also presented.These methods intr oduced in this paper are suitable for image and graph integrated database buildi ng of complicated architectures,and useful for conveniently maintaining and rec onstructing the ancient architectures.

  4. A Review of Distributed Control Techniques for Power Quality Improvement in Micro-grids

    Science.gov (United States)

    Zeeshan, Hafiz Muhammad Ali; Nisar, Fatima; Hassan, Ahmad

    2017-05-01

    Micro-grid is typically visualized as a small scale local power supply network dependent on distributed energy resources (DERs) that can operate simultaneously with grid as well as in standalone manner. The distributed generator of a micro-grid system is usually a converter-inverter type topology acting as a non-linear load, and injecting harmonics into the distribution feeder. Hence, the negative effects on power quality by the usage of distributed generation sources and components are clearly witnessed. In this paper, a review of distributed control approaches for power quality improvement is presented which encompasses harmonic compensation, loss mitigation and optimum power sharing in multi-source-load distributed power network. The decentralized subsystems for harmonic compensation and active-reactive power sharing accuracy have been analysed in detail. Results have been validated to be consistent with IEEE standards.

  5. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  6. Console Log Keeping Made Easier - Tools and Techniques for Improving Quality of Flight Controller Activity Logs

    Science.gov (United States)

    Scott, David W.; Underwood, Debrah (Technical Monitor)

    2002-01-01

    At the Marshall Space Flight Center's (MSFC) Payload Operations Integration Center (POIC) for International Space Station (ISS), each flight controller maintains detailed logs of activities and communications at their console position. These logs are critical for accurately controlling flight in real-time as well as providing a historical record and troubleshooting tool. This paper describes logging methods and electronic formats used at the POIC and provides food for thought on their strengths and limitations, plus proposes some innovative extensions. It also describes an inexpensive PC-based scheme for capturing and/or transcribing audio clips from communications consoles. Flight control activity (e.g. interpreting computer displays, entering data/issuing electronic commands, and communicating with others) can become extremely intense. It's essential to document it well, but the effort to do so may conflict with actual activity. This can be more than just annoying, as what's in the logs (or just as importantly not in them) often feeds back directly into the quality of future operations, whether short-term or long-term. In earlier programs, such as Spacelab, log keeping was done on paper, often using position-specific shorthand, and the other reader was at the mercy of the writer's penmanship. Today, user-friendly software solves the legibility problem and can automate date/time entry, but some content may take longer to finish due to individual typing speed and less use of symbols. File layout can be used to great advantage in making types of information easy to find, and creating searchable master logs for a given position is very easy and a real lifesaver in reconstructing events or researching a given topic. We'll examine log formats from several console position, and the types of information that are included and (just as importantly) excluded. We'll also look at when a summary or synopsis is effective, and when extensive detail is needed.

  7. Imaging techniques applied to quality control of civil manufactured goods obtained starting from ready-to-use mixtures

    Science.gov (United States)

    Bonifazi, Giuseppe; Castaldi, Federica

    2003-05-01

    Concrete materials obtained from the utilization of pre-mixed and ready to use products (central mix-concrete) are more and more used. They represent a big portion of the civil construction market. Such products are used at different scale, ranging from small scale works, as those commonly realized inside and house, an apartment, etc. or at big civil or industrial scale works. In both cases the problem to control the mixtures and the final work is usually realized through the analysis of properly collected samples. Through appropriate sampling it can be derived objective parameters, as size class distribution and composition of the constituting particulate matter, or mechanical characteristics of the sample itself. An important parameter not considered by the previous mentioned approach is "segregation", that is the possibility that some particulate materials migrate preferentially in some zones of the mixtures and/or of the final product. Such a behavior dramatically influences the quality of the product and of the final manufactured good. Actually this behavior is only studied adopting a human based visual approach. Not repeatable analytical procedures or quantitative data processing exist. In this paper a procedure fully based on image processing techniques is described and applied. Results are presented and analyzed with reference to industrial products. A comparison is also made between the new proposed digital imaging based techniques and the analyses usually carried out at industrial laboratory scale for standard quality control.

  8. Electron-beam lithography with character projection technique for high-throughput exposure with line-edge quality control

    Science.gov (United States)

    Ikeno, Rimon; Maruyama, Satoshi; Mita, Yoshio; Ikeda, Makoto; Asada, Kunihiro

    2016-07-01

    The high throughput of character projection (CP) electron-beam (EB) lithography makes it a promising technique for low-to-medium volume device fabrication with regularly arranged layouts, such as for standard-cell logics and memory arrays. However, non-VLSI applications such as MEMS and MOEMS may not be able to fully utilize the benefits of the CP method due to the wide variety of layout figures including curved and oblique edges. In addition, the stepwise shapes that appear because of the EB exposure process often result in intolerable edge roughness, which degrades device performances. In this study, we propose a general EB lithography methodology for such applications utilizing a combination of the CP and variable-shaped beam methods. In the process of layout data conversion with CP character instantiation, several control parameters were optimized to minimize the shot count, improve the edge quality, and enhance the overall device performance. We have demonstrated EB shot reduction and edge-quality improvement with our methodology by using a leading-edge EB exposure tool, ADVANTEST F7000S-VD02, and a high-resolution hydrogen silsesquioxane resist. Atomic force microscope observations were used to analyze the resist edge profiles' quality to determine the influence of the control parameters used in the data conversion process.

  9. FOOD QUALITY CONTROL AND AUTHENTICATION THROUGH COUPLING CHEMOMETRICS TO INSTRUMENTAL FINGERPRINTING TECHNIQUES

    OpenAIRE

    2013-01-01

    Given the emphasis that, especially in the last years, has been placed on food quality and safety, the research which constitutes the basis of the present doctoral thesis was focused on the development of analytical methods to verify the authenticity of foods and for their traceability. In this context, attention was mainly posed on the verification of two closely related aspects: i) the chemical characterization of foods, in terms of the assessment of their composition and the determ...

  10. Rapid quality control for coal seams by gamma ray transmission technique

    CERN Document Server

    Raja-Sekhar, N; Nageswara-Rao, A S

    1999-01-01

    The quality of coal expressed as useful heat value (UHV) depends on various parameters such as fixed carbon, volatiles, ash and moisture. These factors have been assessed and the detailed dependence of UHV on these parameters has been studied for samples of coal from a local mine. The samples were subjected to collimated low energy gamma beams and correlation was obtained between the attenuation coefficient and UHV. The method is reliable, fast and non-destructive and can be used in the field for estimating UHV.

  11. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Energy Technology Data Exchange (ETDEWEB)

    Falate, Rosane [Universidade Estadual de Ponta Grossa, PR (Brazil). Dept. de Informatica; Nike, Karen; Costa Neto, Pedro Ramos da [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Quimica; Cacao Junior, Eduardo; Muller, Marcia; Kalinowski, Hypolito Jose; Fabris, Jose Luis [Universidade Tecnologica Federal do Parana, Curitiba (Brazil). Dept. de Fisica]. E-mail: fabris@utfpr.edu.br

    2007-07-01

    We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method. (author)

  12. Alternative technique for biodiesel quality control using an optical fiber long-period grating sensor

    Directory of Open Access Journals (Sweden)

    Rosane Falate

    2007-01-01

    Full Text Available We report the use of an optical fiber sensor to measure the soybean oil concentration in samples obtained from the mixture of pure biodiesel and commercial soybean oil. The operation of the device is based on the long-period grating sensitivity to the surrounding medium refractive index, which leads to measurable modifications in the grating transmission spectrum. The proposed analysis method results in errors in the oil concentration of 0.4% and 2.6% for pure biodiesel and commercial soybean oil, respectively. Techniques of total glycerol, dynamic viscosity, density, and hydrogen nuclear magnetic resonance spectroscopy were also employed to validate the proposed method.

  13. 77 FR 45307 - Approval and Promulgation of Air Quality Implementation Plans: Georgia; Control Techniques...

    Science.gov (United States)

    2012-07-31

    ...-1-.02(2)(qq) VOC Emissions from Large Petroleum Dry Cleaners; The July 19, 2012, draft SIP revision... Rework Facilities which addresses the applicability thresholds for Barrow, Bartow, Carroll, Hall, Newton... the control of VOC emissions from paper, film and foil coating operations. On January 3, 1991, April...

  14. Application of a colorimetric technique in quality control for printed pediatric orodispersible drug delivery systems containing propranolol hydrochloride

    DEFF Research Database (Denmark)

    Vakili, Hossein; Nyman, Johan O; Genina, Natalja

    2016-01-01

    The feasibility of a colorimetric technique was investigated in CIELAB color space as an analytical quality control method for content uniformity of printed orodispersible pediatric delivery systems. Inkjet printing was utilized to fabricate orodispersibe film formulations containing propranolol...... hydrochloride in a colored ink base using three different edible substrates. A thin sweetener coating layer of saccharin was successfully included in the final dosage forms for palatability purposes using a casting knife. Optical microscopy, scanning electron microscopy and scanning white light interferometry...... analyses were conducted to study the effect of printing on the surface morphology and topography of the substrates. Differential scanning calorimetry and attenuated total reflectance infrared spectroscopy were used to study the solid state properties and possible interactions between the drug...

  15. Evaluation of the effect of Benson's relaxation technique on pain and quality of life of haemodialysis patients: a randomized controlled trial.

    Science.gov (United States)

    Rambod, Masoume; Sharif, Farkhondeh; Pourali-Mohammadi, Nasrin; Pasyar, Nilofar; Rafii, Forough

    2014-07-01

    Haemodialysis patients may suffer from pain and impairment of quality of life. Some complementary interventions, such as relaxation therapy, might affect the pain and quality of life. The present study aimed to identify the effectiveness of Benson's relaxation technique in relieving pain and improving the quality of life in haemodialysis patients. The study was a randomized controlled trial. The data were collected in two haemodialysis units affiliated to Shiraz University of Medical Sciences. A total of 86 haemodialysis patients were randomly assigned to either the intervention (receiving Benson's relaxation technique) or the control group (routine care) from 2011 to 2012. The patients in the intervention groups listened to the audiotape of relaxation technique twice a day each time for 20min for eight weeks. The pain numeric rating scale and Ferrans and Powers Quality of Life Index-dialysis version questionnaire were completed at baseline and 8 weeks after the intervention. The data were analyzed using independent t-test and ANCOVA. The results of ANCOVA showed a significant difference between the intervention and the control group concerning the mean score of the intensity of pain (F=6.03, p=0.01). Moreover, a significant difference was found between the intervention and the control group regarding the total quality of life (F=10.20, p=0.002) and health-functioning (F=8.64, p=0.004), socioeconomic (F=12.45, p=0.001), and family (F=8.52, p=0.005) subscales of quality of life. These findings indicated that Benson's relaxation technique might relieve the intensity of pain and improve the quality of life in haemodialysis patients. Thus, Benson's relaxation technique could be used as part of the care practice for relieving the pain intensity and improvement of the quality of life in haemodialysis patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. The Use of Quality Control and Data Mining Techniques for Monitoring Scaled Scores: An Overview. Research Report. ETS RR-12-20

    Science.gov (United States)

    von Davier, Alina A.

    2012-01-01

    Maintaining comparability of test scores is a major challenge faced by testing programs that have almost continuous administrations. Among the potential problems are scale drift and rapid accumulation of errors. Many standard quality control techniques for testing programs, which can effectively detect and address scale drift for small numbers of…

  17. Advanced Wavefront Control Techniques

    Energy Technology Data Exchange (ETDEWEB)

    Olivier, S S; Brase, J M; Avicola, K; Thompson, C A; Kartz, M W; Winters, S; Hartley, R; Wihelmsen, J; Dowla, F V; Carrano, C J; Bauman, B J; Pennington, D M; Lande, D; Sawvel, R M; Silva, D A; Cooke, J B; Brown, C G

    2001-02-21

    Programs at LLNL that involve large laser systems--ranging from the National Ignition Facility to new tactical laser weapons--depend on the maintenance of laser beam quality through precise control of the optical wavefront. This can be accomplished using adaptive optics, which compensate for time-varying aberrations that are often caused by heating in a high-power laser system. Over the past two decades, LLNL has developed a broad capability in adaptive optics technology for both laser beam control and high-resolution imaging. This adaptive optics capability has been based on thin deformable glass mirrors with individual ceramic actuators bonded to the back. In the case of high-power lasers, these adaptive optics systems have successfully improved beam quality. However, as we continue to extend our applications requirements, the existing technology base for wavefront control cannot satisfy them. To address this issue, this project studied improved modeling tools to increase our detailed understanding of the performance of these systems, and evaluated novel approaches to low-order wavefront control that offer the possibility of reduced cost and complexity. We also investigated improved beam control technology for high-resolution wavefront control. Many high-power laser systems suffer from high-spatial-frequency aberrations that require control of hundreds or thousands of phase points to provide adequate correction. However, the cost and size of current deformable mirrors can become prohibitive for applications requiring more than a few tens of phase control points. New phase control technologies are becoming available which offer control of many phase points with small low-cost devices. The goal of this project was to expand our wavefront control capabilities with improved modeling tools, new devices that reduce system cost and complexity, and extensions to high spatial and temporal frequencies using new adaptive optics technologies. In FY 99, the second year of

  18. Air Quality Assessment Using Interpolation Technique

    Directory of Open Access Journals (Sweden)

    Awkash Kumar

    2016-07-01

    Full Text Available Air pollution is increasing rapidly in almost all cities around the world due to increase in population. Mumbai city in India is one of the mega cities where air quality is deteriorating at a very rapid rate. Air quality monitoring stations have been installed in the city to regulate air pollution control strategies to reduce the air pollution level. In this paper, air quality assessment has been carried out over the sample region using interpolation techniques. The technique Inverse Distance Weighting (IDW of Geographical Information System (GIS has been used to perform interpolation with the help of concentration data on air quality at three locations of Mumbai for the year 2008. The classification was done for the spatial and temporal variation in air quality levels for Mumbai region. The seasonal and annual variations of air quality levels for SO2, NOx and SPM (Suspended Particulate Matter have been focused in this study. Results show that SPM concentration always exceeded the permissible limit of National Ambient Air Quality Standard. Also, seasonal trends of pollutant SPM was low in monsoon due rain fall. The finding of this study will help to formulate control strategies for rational management of air pollution and can be used for many other regions.

  19. Effects of the search technique on the measurement of the change in quality of randomized controlled trials over time in the field of brain injury

    Directory of Open Access Journals (Sweden)

    Yamada Chisa

    2005-02-01

    Full Text Available Abstract Background To determine if the search technique that is used to sample randomized controlled trial (RCT manuscripts from a field of medical science can influence the measurement of the change in quality over time in that field. Methods RCT manuscripts in the field of brain injury were identified using two readily-available search techniques: (1 a PubMed MEDLINE search, and (2 the Cochrane Injuries Group (CIG trials registry. Seven criteria of quality were assessed in each manuscript and related to the year-of-publication of the RCT manuscripts by regression analysis. Results No change in the frequency of reporting of any individual quality criterion was found in the sample of RCT manuscripts identified by the PubMed MEDLINE search. In the RCT manuscripts of the CIG trials registry, three of the seven criteria showed significant or near-significant increases over time. Conclusions We demonstrated that measuring the change in quality over time of a sample of RCT manuscripts from the field of brain injury can be greatly affected by the search technique. This poorly recognized factor may make measurements of the change in RCT quality over time within a given field of medical science unreliable.

  20. Development of rubber forming as a rapid thermoforming technique for continuous fibre reinforced thermoplastic composites. Quality control by process control. Doctoral thesis

    Energy Technology Data Exchange (ETDEWEB)

    Robroek, L.M.J.

    1994-01-01

    The principal goal of the thesis is twofold: the understanding of the fundamental deformation processes of continuous fiber reinforced thermoplastics during a manufacturing cycle of two- or three-dimensional products made from flat laminates; and the development of an efficient thermoforming technique for manufacturing high quality thermoplastic composite products. (Copyright (c) 1994 by L.M.J. Robroek, Structures and Materials Laboratory.)

  1. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  2. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  3. [Quality control of plant extract].

    Science.gov (United States)

    Shao, Yun-dong; Gao, Wen-yuan; Liu, Dan; Jia, Wei; Duan, Hong-Quan; Zhang, Tie-jun

    2003-10-01

    The current situation of plant extract in domestic and international market was analyzed in the paper. The quality control of 20 plant extracts which have reasonably good sales in USA market was compared and analyzed. The analysis of the quality control of six plant extracts indicated that there were two main reasons leading to the varied quality specifications among different suppliers. One reason was that the plant species utilized by different companies were different. The other reason was that the extraction processes were different among different production plants. Comparing with the significant international suppliers of plant extracts, the product quality of Chinese companies were not satisfactory. It was suggested that chromatography and chromatographic fingerprint techniques should be applied to improve the quality control standard of plant extract in our country.

  4. Techniques of data analysis for the electric power quality control; Analise de envoltoria de dados: uma aplicacao no controle da qualidade da energia eletrica

    Energy Technology Data Exchange (ETDEWEB)

    Biondi Neto, Luiz; Chiganer, Luis; Fukuda, Fernando Hideo; Roberto Junior, Vincenzo de; Antonio, Elias Restum; Oliveira, Fabiano S. [Universidade Veiga de Almeida, Rio de Janeiro, RJ (Brazil). Dept. de Ciencias Exatas e Tecnologia]. E-mail: lbiondi@embratel.net.br; lchiganer@uol.com.br; fukuda@uninet.com.br; droberto@uninet.com.br; sosscan@br.homeshopping.com.br; fabiano@imagelink.com.br; Lins, Marcos Estellita [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia de Producao]. E-mail: estelitt@iis.com.br

    2001-07-01

    The electric power quality depends on the proportion of harmonics which compose the electric signal. By other hand, connected equipment to the electric net introduce harmonics on it. In practice, when many equipment are connected to the net the affected electric signal have to be classified according to its pureness. In order to face these situations, it has been developed a maths technique based on lineal programming whose main goal is to measure performance of the operational units when the presence of multiple entrances and multiple exits becomes difficult the comparison. At the end of the analysis, this technique is able to point the relatively efficient units and relatively inefficient units. Finally, this article presents a real case analysis based on measurements of the fundamental tension and its harmonics components of fifth and seventh order in an industrial equipment.

  5. COAL QUALITY CONTROL

    Institute of Scientific and Technical Information of China (English)

    孟祥瑞

    1998-01-01

    Coal storing and loading have much more influence on coal quality. In the paper, a goalprogramming model has been constructed to determine the ideal quantity extracting from stockpileand silos and a quality control model is inferred under the guidance of maximum theory ofdispersed number and practice methods are given to meet production demand, with which a coalmine has achieved a better tech-economic result.

  6. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  7. fuzzy control technique fuzzy control technique applied to modified ...

    African Journals Online (AJOL)

    eobe

    ABSTRACT. In this paper, fuzzy control technique is applied to the modified mathematical model for malaria control presented ... be devised for rule-based systems that deals with continuous ... necessary to use fuzzy logic as it is not easy to follow a particular .... point movement and control is realized and designed. (e.g. α1 ...

  8. Statistical Techniques for Project Control

    CERN Document Server

    Badiru, Adedeji B

    2012-01-01

    A project can be simple or complex. In each case, proven project management processes must be followed. In all cases of project management implementation, control must be exercised in order to assure that project objectives are achieved. Statistical Techniques for Project Control seamlessly integrates qualitative and quantitative tools and techniques for project control. It fills the void that exists in the application of statistical techniques to project control. The book begins by defining the fundamentals of project management then explores how to temper quantitative analysis with qualitati

  9. Effects of Mind Sound Resonance Technique (Yogic Relaxation) on Psychological States, Sleep Quality, and Cognitive Functions in Female Teachers: A Randomized, Controlled Trial.

    Science.gov (United States)

    Rao, Manas; Metri, Kashinath G; Raghuram, Nagaratna; Hongasandra, Nagendra R

    2017-01-01

    Context • Several studies have revealed a high rate of physical and psychological problems from stress among schoolteachers. Yoga is one of the mind-body interventions known to alleviate stress and effects. The mind sound resonance technique (MSRT), a yoga-based, mindfulness relaxation is recognized as having a positive influence on physical and psychological health. Objectives • The study intended to examine the effects of an MSRT intervention for 1 mo on perceived stress, quality of sleep, cognitive function, state and trait anxiety, psychological distress, and fatigue among female teachers. Design • The study was a randomized, controlled trial. Setting • The study occurred at 2 primary schools in Bangalore City, India. Participants • Sixty female teachers, aged between 30 and 55 y, from the 2 schools were enrolled in the study. Intervention • The participants were randomly divided into an MSRT group (n = 30) and a control group (n = 30). Participants in the MSRT group participated in MSRT for 30 min/d, 5 d/wk, for the duration of 1 mo. The participants in the control group followed their normal daily routines. Outcome measures • Perceived stress, sleep quality, cognitive function, anxiety, psychological distress, fatigue, and self-esteem were assessed using standardized assessment tools at baseline and after 1 mo of the intervention. Results • In the MSRT group, a significant reduction occurred for 5 variables: (1) 47.01% for perceived stress (P function, but the change was not significant (P = .111). On the other hand, the control group showed significant increases in 5 variables: (1) 55.56% for perceived stress (P function (P = .002). A comparison between the 2 groups showed significant differences in 7 variables: (1) perceived stress (P function (P = .083). Conclusions • In the current study, the practice of MSRT facilitated a reduction in the levels of stress, anxiety, fatigue, and psychological distress. The relaxation technique also

  10. A quality by design approach using artificial intelligence techniques to control the critical quality attributes of ramipril tablets manufactured by wet granulation.

    Science.gov (United States)

    Aksu, Buket; Paradkar, Anant; de Matas, Marcel; Özer, Özgen; Güneri, Tamer; York, Peter

    2013-02-01

    Quality by design (QbD) is an essential part of the modern approach to pharmaceutical quality. This study was conducted in the framework of a QbD project involving ramipril tablets. Preliminary work included identification of the critical quality attributes (CQAs) and critical process parameters (CPPs) based on the quality target product profiles (QTPPs) using the historical data and risk assessment method failure mode and effect analysis (FMEA). Compendial and in-house specifications were selected as QTPPs for ramipril tablets. CPPs that affected the product and process were used to establish an experimental design. The results thus obtained can be used to facilitate definition of the design space using tools such as design of experiments (DoE), the response surface method (RSM) and artificial neural networks (ANNs). The project was aimed at discovering hidden knowledge associated with the manufacture of ramipril tablets using a range of artificial intelligence-based software, with the intention of establishing a multi-dimensional design space that ensures consistent product quality. At the end of the study, a design space was developed based on the study data and specifications, and a new formulation was optimized. On the basis of this formulation, a new laboratory batch formulation was prepared and tested. It was confirmed that the explored formulation was within the design space.

  11. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  12. FABRIC QUALITY CONTROL SYSTEMS

    Directory of Open Access Journals (Sweden)

    Özlem KISAOĞLU

    2006-02-01

    Full Text Available Woven fabric quality depends on yarn properties at first, then weaving preparation and weaving processes. Defect control of grey and finished fabric is done manually on the lighted tables or automatically. Fabrics can be controlled by the help of the image analysis method. In image system the image of fabrics can be digitized by video camera and after storing controlled by the various processing. Recently neural networks, fuzzy logic, best wavelet packet model on automatic fabric inspection are developed. In this study the advantages and disadvantages of manual and automatic, on-line fabric inspection systems are given comparatively.

  13. Ultrasonic techniques for process monitoring and control.

    Energy Technology Data Exchange (ETDEWEB)

    Chien, H.-T.

    1999-03-24

    Ultrasonic techniques have been applied successfully to process monitoring and control for many industries, such as energy, medical, textile, oil, and material. It helps those industries in quality control, energy efficiency improving, waste reducing, and cost saving. This paper presents four ultrasonic systems, ultrasonic viscometer, on-loom, real-time ultrasonic imaging system, ultrasonic leak detection system, and ultrasonic solid concentration monitoring system, developed at Argonne National Laboratory in the past five years for various applications.

  14. Evaluation of the effectiveness of manual chest physiotherapy techniques on quality of life at six months post exacerbation of COPD (MATREX: a randomised controlled equivalence trial

    Directory of Open Access Journals (Sweden)

    Cross Jane L

    2012-07-01

    Full Text Available Abstract Background Manual chest physiotherapy (MCP techniques involving chest percussion, vibration, and shaking have long been used in the treatment of respiratory conditions. However, methodological limitations in existing research have led to a state of clinical equipoise with respect to this treatment. Thus, for patients hospitalised with an exacerbation of Chronic Obstructive Pulmonary Disease (COPD, clinical preference tends to dictate whether MCP is given to assist with sputum clearance. We standardised the delivery of MCP and assessed its effectiveness on disease-specific quality of life. Methods In this randomised, controlled trial powered for equivalence, 526 patients hospitalised with acute COPD exacerbation were enrolled from four centres in the UK. Patients were allocated to receive MCP plus advice on airway clearance or advice on chest clearance alone. The primary outcome was a COPD specific quality of life measure, the Saint Georges Respiratory Questionnaire (SGRQ at six months post randomisation. Analyses were by intention to treat (ITT. This study was registered, ISRCTN13825248. Results All patients were included in the analyses, of which 372 (71% provided evaluable data for the primary outcome. An effect size of 0·3 standard deviations in SGRQ score was specified as the threshold for superiority. The ITT analyses showed no significant difference in SGRQ for patients who did, or did not receive MCP (95% CI −0·14 to 0·19. Conclusions These data do not lend support to the routine use of MCP in the management of acute exacerbation of COPD. However, this does not mean that MCP is of no therapeutic value to COPD patients in specific circumstances.

  15. Use of the gamma-ray absorption technique as a quality control procedure in the manufacture of powder metal shaped charge liners

    CSIR Research Space (South Africa)

    Lawrie, JJ

    2010-09-01

    Full Text Available The use of the gamma-ray absorption technique as a tool in evaluating the quality of manufactured powder metal liners was investigated. With powder metal liners, it is not only of interest to know whether the liner conforms geometrically...

  16. [Quality control in parasitology].

    Science.gov (United States)

    Vasallo Matilla, F

    2001-01-01

    Between 1990 and 1996 we coordinated a Quality Control (QC) Program in Parasitology directed to Public Health Institutions in Spain. Periodically, parasited specimens, mainly feces or blood, were sent to Microbiology Laboratories for identification. Each QC was accompanied by a short clinic and epidemiological information in order to help in the diagnostic approach. After the answers to the QC were received a bulletin that included the solution to the QC, comments on the several answers received and a chapter with parasitological themes related with the QC, was sent to each participating Laboratory. The bulletin was accompanied by a card that included a photograph and a short description of the organism object of the QC.

  17. Posttranslational modification and quality control.

    Science.gov (United States)

    Wang, Xuejun; Pattison, J Scott; Su, Huabo

    2013-01-18

    Protein quality control functions to minimize the level and toxicity of misfolded proteins in the cell. Protein quality control is performed by intricate collaboration among chaperones and target protein degradation. The latter is performed primarily by the ubiquitin-proteasome system and perhaps autophagy. Terminally misfolded proteins that are not timely removed tend to form aggregates. Their clearance requires macroautophagy. Macroautophagy serves in intracellular quality control also by selectively segregating defective organelles (eg, mitochondria) and targeting them for degradation by the lysosome. Inadequate protein quality control is observed in a large subset of failing human hearts with a variety of causes, and its pathogenic role has been experimentally demonstrated. Multiple posttranslational modifications can occur to substrate proteins and protein quality control machineries, promoting or hindering the removal of the misfolded proteins. This article highlights recent advances in posttranslational modification-mediated regulation of intracellular quality control mechanisms and its known involvement in cardiac pathology.

  18. General aviation fuel quality control

    Science.gov (United States)

    Poitz, H.

    1983-01-01

    Quality control measures for aviation gasoline, and some of the differences between quality control on avgas and mogas are discussed. One thing to keep in mind is that with motor gasoline you can always pull off to the side of the road. It's not so easy to do in an airplane. Consequently, there are reasons for having the tight specifications and the tight quality control measures on avgas as compared to motor gasoline.

  19. Visual Quality Control Techniques Used to Concrete Pylon Column Construction%混凝土塔柱施工外观质量控制技术

    Institute of Scientific and Technical Information of China (English)

    韦理仁; 张家伦; 陈新

    2016-01-01

    To improve the visual quality of concrete pylon columns of urban bridges ,the con‐struction of the pylon columns of Jiangshun Bridge was cited as an example ,to study the key visual quality control techniques used during the pylon column construction .The formwork was rational‐ly divided according to the structural characteristics of the pylon columns ,the joints between every two divisions adopts tongue‐and‐groove joints ,and the connection of the arc‐chamfered steel form‐work and the timber formwork was optimized .The WISA plate and the I‐shaped timber back ribs were connected by nails driven from the opposite side .Besides the tie rods ,there are embedded climbing cones and fining twisted steel bars installed at the base opening of the formwork ,aiming to gain the twofold tightening effect .A testing block of the pylon saddle was prepared ,comparison was made among different mold release agents ,and the salad oil was finally chosen as the release agent .During the construction of the pylon column concrete ,the timbers with length equal to the thickness of the pylon column walls were used as inner shoring ,to ensure the width of the form‐work top opening .The horizontal nails in the construction joints at the top opening of the form‐work were backed by through‐length battens to control flatness .A pump washing cycling system was designed for the ordered draining of waste water .By taking the aforementioned measures ,the pylon columns of the Jiangshun Bridge were constructed to be solid columns with pleasing sur‐f aces .%为提高城市桥梁混凝土塔柱的外观质量,以江顺大桥桥塔塔柱施工为例,对塔柱施工中混凝土外观质量控制的关键技术进行研究。结合塔柱结构特点合理进行模板分块,分块拼缝采用企口缝形式,并对圆弧倒角钢模与木模的连接进行优化处理;W IS A面板与木工字背肋的连接采用反面打钉的连接方式;模板底口除了设置拉杆

  20. 统计质量保证技术在分析测试实验室内部质量控制中的应用%Application of SQA Techniques to Analytical and Testing Laboratories for Internal Quality Control

    Institute of Scientific and Technical Information of China (English)

    王斗文; 万秉忠

    2001-01-01

    对通过统计质量保证( SQA)技术进行分析测试实验室内部质量控制( IQC)的方法作了初探。研究结果表明,SQA技术的应用能保证实验室始终处于统计受控状态,确保测试数据的有效性,有利于分析测试实验室质量保证活动的开展。%In this paper,a method of internal quality control for analytical and testing laboratories by statistical quality assurance(SQA) techniques is discussed.Application of SQA techniques can be continuously ensure that analytical and testing data of the laboratories are in statistical _ control state,thus guaranteeing the data quality and indicating areas of potential improvement for the laboratories.

  1. 水泥路面加铺沥青改造质量控制技术%Paving asphalt concrete pavement quality control techniques

    Institute of Scientific and Technical Information of China (English)

    王小兵

    2014-01-01

    总结归纳了旧路面病害检测的内容及方法,从施工管理角度出发,对沥青面层的加铺进行了质量控制,包括沥青、集料、设置试验段等内容,并通过平整度、渗水系数等控制掺量检验,对改造工程质量进行了检查验收。%This paper sums up the old road surface plant disease detection contents and methods, from the angle of construction management of asphalt road surface of the road to quality control, such as asphalt, aggregate, set up test section content, finally, through permeable coefficient control parameter inspection, inspection on project quality acceptance.

  2. Quality control in gastrointestinal surgery.

    Science.gov (United States)

    Ramírez-Barba, Ector Jaime; Arenas-Moya, Diego; Vázquez-Guerrero, Arturo

    2011-01-01

    We analyzed the Mexican legal framework, identifying the vectors that characterize quality and control in gastrointestinal surgery. Quality is contemplated in the health protection rights determined according to the Mexican Constitution, established in the general health law and included as a specific goal in the actual National Development Plan and Health Sector Plan. Quality control implies planning, verification and application of corrective measures. Mexico has implemented several quality strategies such as certification of hospitals and regulatory agreements by the General Salubrity Council, creation of the National Health Quality Committee, generation of Clinical Practice Guidelines and the Certification of Medical Specialties, among others. Quality control in gastrointestinal surgery must begin at the time of medical education and continue during professional activities of surgeons, encouraging multidisciplinary teamwork, knowledge, abilities, attitudes, values and skills that promote homogeneous, safe and quality health services for the Mexican population.

  3. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  4. Quality Control Techniques in Downsizing of 1: 50000 Scale Topographical Maps%浅谈1:5万地形图缩编生产中的质量控制与技巧

    Institute of Scientific and Technical Information of China (English)

    陈家义

    2011-01-01

    According to the analysis of the problems solved during the downsizing production of 1:50000 scale topographical maps, some quality control techniques have been developed and summarized. A detailed discussion on the usage of the techniques is provided to improve the quality control of the production.%本文根据1:5万地形图缩编生产的特点,针对1:5万地形图缩编生产及质量检查中发现的问题,做了一些分析和探讨,结合生产实践总结了一些解决质量问题的方法与技巧,对地形图生产的质量控制有一定的借鉴意义。

  5. 10 CFR 26.137 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Quality assurance and quality control. 26.137 Section 26....137 Quality assurance and quality control. (a) Quality assurance program. Each licensee testing... metabolites. (b) Performance testing and quality control requirements for validity screening tests....

  6. [Quality controls in medical mycology].

    Science.gov (United States)

    Kauffmann-Lacroix, C; Cassaing, S; Bessieres, M-H; Mayet, D; Linas, M-D; Roques, C

    2011-03-01

    The Quality Management System in medical mycology refers to the systematic monitoring with internal and external quality controls: it needs to be organized in the laboratory. ISO 15189 standard is not precise in how to demonstrate the correctness of tests, in terms of frequency and requirements for quality controls QC. That's why the COFRAC, the French Accreditation Committee has published guides to which we should refer. The laboratory has to apply internal Quality Control Programs. They consist of various tests to check the reagents including the culture media. Reference strains have to be provided and preparations of homemade reagents are needed, because few are commercialized. Maintaining the competence of the technical staff through identification of unknown strains is also required. In the fungal serology field, home made antibodies with pooled sera or antigen controls are needed. This monitoring has to follow the recommandations from the Cofrac technical guide LAB GTA 06. For quantitative analysis, the Levey-Jennings chart is a graph with quality control data plotted on to give a visual indication. Some external QC references, besides the national quality control AFSSAPS, are available. Data evaluation, corrective actions in case of out of range results and preventive actions have to be determined in the Quality System documents and presented in the annual management review. Copyright © 2011. Published by Elsevier SAS.

  7. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  8. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  9. Application of optimisation techniques in groundwater quantity and quality management

    Indian Academy of Sciences (India)

    Amlan Das; Bithin Datta

    2001-08-01

    This paper presents the state-of-the-art on application of optimisation techniques in groundwater quality and quantity management. In order to solve optimisation-based groundwater management models, researchers have used various mathematical programming techniques such as linear programming (LP), nonlinear programming (NLP), mixed-integer programming (MIP), optimal control theory-based mathematical programming, differential dynamic programming (DDP), stochastic programming (SP), combinatorial optimisation (CO), and multiple objective programming for multipurpose management. Studies reported in the literature on the application of these methods are reviewed in this paper.

  10. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  11. The effect of HRM on the relationship between quality management techniques and performance

    DEFF Research Database (Denmark)

    do Nascimento Gambi, Lillian; Jørgensen, Frances; Cecílio Gerolamo, Mateus

    2014-01-01

    This study analyzes the effect of HRM approaches (control versus commitment) on the relationship between quality management techniques and operational performance. The research model and hypotheses devised are tested using data collected from 250 Brazilian and Danish manufacturing companies....... The study shows that the relationship between quality management techniques and performance is influenced by HRM approaches, but provides counterevidence to the prevailing assumption that commitment-oriented HRM is generally more appropriate to increase performance than a control-oriented approach. Rather......, the paper demonstrates that control-oriented HRM enhances the positive effects of quality management techniques on performance, irrespective of the core characteristics of these techniques....

  12. 冷却肉的加工技术及质量控制%Technique and Quality Control of Chilled Meat

    Institute of Scientific and Technical Information of China (English)

    张子平

    2001-01-01

    冷却肉(猪肉)是指宰后胴体迅速进行冷却处理,使胴体温度在24小时内降为0-4℃,并在后续的分割、包装、流通和零售等过程中,始终处于0-4℃范围内的生鲜肉(猪肉)。微生物的污染是冷却肉产品质量的重要危害,因此,我们在生产加工与流通过程中实施HACCP系统监控,以确保产品的安全卫生。冷却肉的流通结合实际情况,目前采用加工厂内真空大包装,运输到超级市场后,制作成托盘保鲜小包装。%Chil led meat was the fresh meat cut and deboned after quickly chilling to 0-4 ℃within24hours.Thetemperature of chilled meat was kept at 0-4℃ during packaging, distributing and being retailed. The quality of chilled meat was controlled by HACCP system.

  13. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  14. Validated HPTLC technique for simultaneous evaluation of biomarkers gallic acid and quercetin in Trichosanthes dioica Roxb.: A systematic approach for quality control of herbals

    Directory of Open Access Journals (Sweden)

    Md. Sarfaraj Hussain

    2017-06-01

    Full Text Available Objective: To investigate the simultaneous quantification of two biologically active elements, flavonoids gallic acid (GA and quercetin (QE, in methanolic extract of Trichosanthes dioica that was customarily used to lower blood sugar and cholesterol. Methods: Silica gel 60F254 having receded with aluminum plate was applied for the separation. We used toluene-ethyl acetate-formic acid (5:4:1, v/v/v as a solvent system for the separation. Results: At 270 nm in reflectance mode densitometric analysis was performed. Squeezed bands for GA and QE were achieved at Rf (0.31 ± 0.03 and (0.50 ± 0.02. The scheme was validated for sensitivity, specificity, limit of detection and quantification. Linear relationship was found between the concentration range of 100–1 000 ng spot–1 for GA and 150–900 ng spot–1 for GA and QE, respectively. The instrumental precision was noted to be 1.03–1.96 (% RSD and 1.09–1.98 (% RSD for GA and QE, separately. Methodology specificity was determined at three different study point with varying concentration for recovery studies. Mean % recovery was noted to be 99.4%–99.9% and 98.7%–99.3% and the content estimated as (31.00 ± 1.18% and (39.00 ± 1.24% for GA and QE, respectively. Conclusions: The developed high performance thin layer chromatography scheme can be used for routine quality control analysis of Trichosanthes dioica and several other formulations containing these markers.

  15. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  16. Temperature Control System Using Fuzzy Logic Technique

    Directory of Open Access Journals (Sweden)

    Isizoh A N

    2012-06-01

    Full Text Available Fuzzy logic technique is an innovative technology used in designing solutions for multi-parameter and non-linear control models for the definition of a control strategy. As a result, it delivers solutions faster than the conventional control design techniques. This paper thus presents a fuzzy logic based-temperature control system, which consists of a microcontroller, temperature sensor, and operational amplifier, Analogue to Digital Converter, display interface circuit and output interface circuit. It contains a design approach that uses fuzzy logic technique to achieve a controlled temperature output function.

  17. Techniques to improve technological and sanitary quality

    OpenAIRE

    David, C.; Celette, F.; Abecassis, J; Carcea, M.; Dubois, D.; Friedel, J. K.; Hellou, G.; Jeuffroy, M.-H.; Mäder, P.; Thomsen, I.K.

    2012-01-01

    Agronomical ways for better quality and safety Choice of cultivar is an efficient way to obtain higher grain quality. Intercropping legumes (grain or forage) improves weed competition and N availability for wheat crop or succeeding crop. Green manure can be an effective alternative to farmyard manure. Fertilization with readily available nitrogen improves yield and quality when water is available. Reduced tillage affects soil fertility and wheat yield but has little effects on grain qualit...

  18. Controlling the quality of nanocrystalline silicon made by hot-wire chemical vapor deposition by using a reverse H2 profiling technique

    NARCIS (Netherlands)

    Li, H. B. T.; Franken, R.H.; Stolk, R.L.; van der Werf, C.H.M.; Rath, J.K.; Schropp, R.E.I.

    2008-01-01

    Hydrogen profiling, i.e., decreasing the H2 dilution during deposition, is a well-known technique to maintain a proper crystalline ratio of the nanocrystalline (nc-Si:H) absorber layers of plasma-enhanced chemical vapor-deposited (PECVD) thin film solar cells. With this technique a large increase in

  19. Controlling the quality of nanocrystalline silicon made by hot-wire chemical vapor deposition by using a reverse H2 profiling technique

    NARCIS (Netherlands)

    Li, H. B. T.; Franken, R.H.; Stolk, R.L.; van der Werf, C.H.M.; Rath, J.K.; Schropp, R.E.I.

    2008-01-01

    Hydrogen profiling, i.e., decreasing the H2 dilution during deposition, is a well-known technique to maintain a proper crystalline ratio of the nanocrystalline (nc-Si:H) absorber layers of plasma-enhanced chemical vapor-deposited (PECVD) thin film solar cells. With this technique a large increase in

  20. Absolute absorbed dose measurements with an array of ionization chambers as part of a routine procedure of quality control for the VMAT technique; Medidas de dosis absorbida absoluta con un array de camaras de ionizacion como parte de un procedimiento rutinario de control de calidad para la tecnica VMAT

    Energy Technology Data Exchange (ETDEWEB)

    Clemente Gutierrez, F.; Cabello Murillo, E.; Ramirez Ros, J. C.; Casa de Julian, M. A. de la

    2011-07-01

    Arcotheraphy techniques volumetric modulated (VMAT) treatments involve continuous variation of the gantry rotation speed, positions of the sheets and dose rate. Since all treatments are administered by continuous arcs, these techniques require quality control procedures to ensure quick and easy constancy of the calibration factor (total absorbed dose) for any gantry angle. We report here a simple method of quality control for the measurement of the calibration factor using an array of ionization chambers. The measurements were performed on a unit of 6 MV Elekta Synergy with VMAT, belonging to the Radiation Oncology service of the Defense Central Hospital Gomez Ulla.

  1. Techniques of Ultrasound Cavitation Control

    Directory of Open Access Journals (Sweden)

    S. P. Skvortsov

    2015-01-01

    Full Text Available The control methods of ultrasonic cavitation applied now within the range from 20 kHz to 80 kHz use either control of ultrasound source parameters (amplitude, acoustic power, etc. or control of one of the cavitation effects (erosion of materials, sonoluminescence, power of acoustic noise, etc.. These methods provide effective management of technological processes, however, make it impossible to relate the estimated effect with parameters of pulsations of cavitation bubbles. This is, mainly, due to influence of a number of uncontrollable parameters, in particular, such as temperature, composition of liquid, gas content, etc. as well as because of the difficulty to establish interrelation between the estimated effect and parameters of pulsations. As a result, in most cases it is difficult to compare controlled parameters of ultrasonic cavitation among themselves, and quantitative characteristics of processes become depending on the type of ultrasonic installation and conditions of their measurement.In this regard, methods to determine parameters of bubble pulsations through sounding a cavitation area by low-intensity laser radiation or to record cavitation noise sub-harmonics reflecting dynamics of changing radius of cavitation bubbles are of interest. The method of optical sounding, via the analysis of spectral components of a scattered signal recorded by a photo-detector, allows us to define a phase of the bubbles collapse with respect to the sound wave and a moving speed of the bubbles wall, as well as to estimate a cavitation index within the light beam section.The method to record sub-harmonicas of cavitation noise allows us to define parameters of pulsations, average for cavitation areas.The above methods allow us both to study mechanisms of cavitation action and to form quantitative criteria of its efficiency based on the physical processes, rather than their consequences and are convenient for arranging a feedback in the units using

  2. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  3. Soft Computing Techniques for Process Control Applications

    Directory of Open Access Journals (Sweden)

    Rahul Malhotra

    2011-09-01

    Full Text Available Technological innovations in soft computing techniques have brought automation capabilities to new levelsof applications. Process control is an important application of any industry for controlling the complexsystem parameters, which can greatly benefit from such advancements. Conventional control theory isbased on mathematical models that describe the dynamic behaviour of process control systems. Due to lackin comprehensibility, conventional controllers are often inferior to the intelligent controllers. Softcomputing techniques provide an ability to make decisions and learning from the reliable data or expert’sexperience. Moreover, soft computing techniques can cope up with a variety of environmental and stabilityrelated uncertainties. This paper explores the different areas of soft computing techniques viz. Fuzzy logic,genetic algorithms and hybridization of two and abridged the results of different process control casestudies. It is inferred from the results that the soft computing controllers provide better control on errorsthan conventional controllers. Further, hybrid fuzzy genetic algorithm controllers have successfullyoptimized the errors than standalone soft computing and conventional techniques.

  4. Power quality problems and mitigation techniques

    CERN Document Server

    Singh, Bhim; Al-Haddad, Kamal

    2014-01-01

    Maintaining a stable level of power quality in the distribution network is a growing challenge due to increased use of power electronics converters in domestic, commercial and industrial sectors. Power quality deterioration is manifested in increased losses; poor utilization of distribution systems; mal-operation of sensitive equipment and disturbances to nearby consumers, protective devices, and communication systems. However, as the energy-saving benefits will result in increased AC power processed through power electronics converters, there is a compelling need for improved understanding o

  5. sampling plans for monitoring quality control process at a plastic ...

    African Journals Online (AJOL)

    Dr Obe

    managing these -activities in an intercultural environment will be of increasing ... adoption of new managerial concepts and .techniques among ... sample for both monitoring and quality control purposes. Prybrutok, et al. 7 observed that the.

  6. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  7. Advanced Control Techniques with Fuzzy Logic

    Science.gov (United States)

    2014-06-01

    AFRL-RQ-WP-TR-2014-0175 ADVANCED CONTROL TECHNIQUES WITH FUZZY LOGIC James E. Combs Structural Validation Branch Aerospace Vehicles...TECHNIQUES WITH FUZZY LOGIC 5a. CONTRACT NUMBER In-house 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 62201F 6. AUTHOR(S) James E. Combs...unlimited. 13. SUPPLEMENTARY NOTES PA Case Number: 88ABW-2014-3281; Clearance Date: 09 Jul 2014. 14. ABSTRACT Research on the Fuzzy Logic control

  8. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  9. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts...

  10. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  11. Statistical quality control through overall vibration analysis

    Science.gov (United States)

    Carnero, M. a. Carmen; González-Palma, Rafael; Almorza, David; Mayorga, Pedro; López-Escobar, Carlos

    2010-05-01

    The present study introduces the concept of statistical quality control in automotive wheel bearings manufacturing processes. Defects on products under analysis can have a direct influence on passengers' safety and comfort. At present, the use of vibration analysis on machine tools for quality control purposes is not very extensive in manufacturing facilities. Noise and vibration are common quality problems in bearings. These failure modes likely occur under certain operating conditions and do not require high vibration amplitudes but relate to certain vibration frequencies. The vibration frequencies are affected by the type of surface problems (chattering) of ball races that are generated through grinding processes. The purpose of this paper is to identify grinding process variables that affect the quality of bearings by using statistical principles in the field of machine tools. In addition, an evaluation of the quality results of the finished parts under different combinations of process variables is assessed. This paper intends to establish the foundations to predict the quality of the products through the analysis of self-induced vibrations during the contact between the grinding wheel and the parts. To achieve this goal, the overall self-induced vibration readings under different combinations of process variables are analysed using statistical tools. The analysis of data and design of experiments follows a classical approach, considering all potential interactions between variables. The analysis of data is conducted through analysis of variance (ANOVA) for data sets that meet normality and homoscedasticity criteria. This paper utilizes different statistical tools to support the conclusions such as chi squared, Shapiro-Wilks, symmetry, Kurtosis, Cochran, Hartlett, and Hartley and Krushal-Wallis. The analysis presented is the starting point to extend the use of predictive techniques (vibration analysis) for quality control. This paper demonstrates the existence

  12. Contributions of CCLM to advances in quality control.

    Science.gov (United States)

    Kazmierczak, Steven C

    2013-01-01

    Abstract The discipline of laboratory medicine is relatively young when considered in the context of the history of medicine itself. The history of quality control, within the context of laboratory medicine, also enjoys a relatively brief, but rich history. Laboratory quality control continues to evolve along with advances in automation, measurement techniques and information technology. Clinical Chemistry and Laboratory Medicine (CCLM) has played a key role in helping disseminate information about the proper use and utility of quality control. Publication of important advances in quality control techniques and dissemination of guidelines concerned with laboratory quality control has undoubtedly helped readers of this journal keep up to date on the most recent developments in this field.

  13. Quality assurance of a conformal treatment technique

    Energy Technology Data Exchange (ETDEWEB)

    Kroes, A.P.G.; Bruinvis, I.A.D.; Lanson, J.H.; Uiterwaal, G.J. [Nederlands Kanker Inst. `Antoni van Leeuwenhoekhuis`, Amsterdam (Netherlands)

    1995-12-01

    For a parotid gland irradiation technique with a pair of oblique wedged photon beams the target coverage near the surface was investigated. The planning target volume extends to 5 millimetres under the skin; a minimum target dose of 95% is required when the dose at the centre is set to 100%. The treatment technique was simulated on a water phantom with a beam of 45 degree gantry angle, 55 degree wedge, 8 x 10 cm{sup 2} field size and the isocentre at 2 cm depth. Beam energies of 4, 6 and 8 MV were used. The dose distributions were measured in two orthogonal planes through the isocentre perpendicular to the water surface with p-type silicon diodes along lines through the isocentre every 45 degrees. Dose distributions were calculated in these planes with our 3-D planning system (U-Mplan, University of Michigan planning system), with model parameters are fitted to depth dose curves and profiles of open and wedged normally incident beams. The location of the 95% isodose was determined in five points near the surface. For 4, 6 and 8 MV the depths of the 95% isodose were 6.0, 10.3 and 11.0 mm, respectively. The depths of the 95% points of single normally incident open fields were 6.0, 9.0 and 11.5 mm, respectively. The treatment planning system (TPS) calculated the 95% isodose for the parotid technique at 5.5, 7.3 and 11.5 mm depths, for 4, 6 and 8 MV, respectively. Thus for 6 MV the 95% was 3 mm deeper than calculated by the TPS; 2 mm were caused by the inaccuracy of the open field depth dose curve fit in the build-up region. The depth near the surface of the 95% isodose for this treatment technique can be estimated from single open field depth dose curves with acceptable accuracy. This result is not obvious because the effects of the wedge and oblique incidence on the dose distribution are also involved. The TPS performed well for the 4 and 8 MV beams, but for treatments with 6 MV target under dosage could have remained undetected. (Abstract Truncated)

  14. Application and operating technique for quality control of bone imaging%骨显像的技术操作及应用与质量控制

    Institute of Scientific and Technical Information of China (English)

    陈瑞玲; 冯瑾; 杨芳

    2012-01-01

    目的 探讨通过注意骨显像的技术操作要点及正确使用骨显像的各种方式提高骨显像影像质量的方法.方法 对本科2011年~2012年2543例接受骨显像检查的患者进行分析.显像仪器为GE公司生产的Infinia VC Hawkeye双探头带符合线路SPECT,配低能通用型准直器.全身骨显像、局部骨显像、SPECT/CT骨显像静脉注入显像剂,注射后嘱患者饮水500~1000ml,于3~4h后开始检查;三时相骨显像采用“弹丸”式静脉注射显像剂,于即刻、10min、3~4h分别采集血流相、血池相和延迟相.结果 2543例接受骨显像检查的患者,行全身骨显像2543例(100%),行三时相骨显像366(14.4%),行局部骨显像168例(6.6%),行SPECT/CT骨显像81例(3.2%).结论 技师可通过熟练掌握不同方式骨显像的操作技术及其适应症,并充分利用核医学全身显像、局部显像等各种显像方式的优势来提高骨显像影像质量.%Objective To investigate methods for improving the quality of bone scan imaging through operational technical points and proper pattern of bone Imaging. Methods Bone scans of 2 543 patients during 2011 ~ 2012 were reviewed. Imaging instrument was the GE Infinia VC Hawkeye dual-detect coincidence SPECT/CT, with low energy universal colli-mator. Bone Imaging agent was injected intravenously in whole body bone imaging, local bone imaging, and SPECT/CT imaging. Patients were asked to drink 500~1 000 ml water after injection, and accepted examination in 3~4 hours. Pellet injection was used in three-phase bone scan, blood flow imaging, blood pool imaging and late imaging were taken immediately, and 3~4 hours respectively. Results 2 543 patients received bone scan. 2 543 cases were taken whole body bone Imaging (100%), 366 cases were taken three phase bone Imaging (14. 4%), 168 cases were taken local bone Imaging (6. 6%), 81 cases were taken SPECT/CT (3. 2%). Conclusion Technicians can impove the quality of bone scan

  15. 75 FR 59179 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2010-09-27

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Flexible Packaging Printing AGENCY: Environmental Protection... Available Control Technology (RACT) for sources covered by EPA's Control Techniques Guidelines (CTG) for...

  16. 虹吸式雨水排水系统施工技术和质量控制%On construction technique of hydrocone rainwater drainage system and its quality control

    Institute of Scientific and Technical Information of China (English)

    王俊

    2014-01-01

    The paper introduces the working principle and craft procedure of the roof hydrocone rainwater drainage system,illustrates the con-struction techniques for the measurement and calculation,pipeline prefabrication,positioning and lining,and manufacturing and installation of support,and indicates its quality control measures,so as to provide some reference for similar constructions and projects.%介绍了屋面虹吸式雨水排水系统的工作原理及工艺流程,着重对测量计算、管道预制、定位放线、支架制作安装等施工技术进行了阐述,并说明了其质量控制措施,对其他类似工程施工具有借鉴作用。

  17. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  18. Active load control techniques for wind turbines.

    Energy Technology Data Exchange (ETDEWEB)

    van Dam, C.P. (University of California, Davis, CA); Berg, Dale E.; Johnson, Scott J. (University of California, Davis, CA)

    2008-07-01

    This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

  19. [Quality control in microbiology (author's transl)].

    Science.gov (United States)

    Lamanna, A

    1977-01-01

    The microbiology quality control importance is emphasized and some particular problems that quality control presents in microbiology are also indicated. There are two types of microbiology quality control as well as for hematology and chemical chemistry: collective quality control, between more laboratories, and individual quality control, in the sphere of each laboratory. A.M.O.I. (Associazione Microbiologi Ospedalieri Italiani) and I.S.V.T. (Istituto Sieroterapico Vaccinogeno Toscano) Sclavo collaborating, have organized a collective quality control between laboratories of different hospitals during the year 1974 and 1975. The results of this control are reported. Although preliminary, they indicate practical importance of microbiology control. During 1975, in fact, the pathogens isolated have been in high percentage than 1976. At last, the future quality control's program aiming at methods's standardization and technical, methodical instructions is indicated.

  20. PROCESS VARIABILITY REDUCTION THROUGH STATISTICAL PROCESS CONTROL FOR QUALITY IMPROVEMENT

    Directory of Open Access Journals (Sweden)

    B.P. Mahesh

    2010-09-01

    Full Text Available Quality has become one of the most important customer decision factors in the selection among the competing product and services. Consequently, understanding and improving quality is a key factor leading to business success, growth and an enhanced competitive position. Hence quality improvement program should be an integral part of the overall business strategy. According to TQM, the effective way to improve the Quality of the product or service is to improve the process used to build the product. Hence, TQM focuses on process, rather than results as the results are driven by the processes. Many techniques are available for quality improvement. Statistical Process Control (SPC is one such TQM technique which is widely accepted for analyzing quality problems and improving the performance of the production process. This article illustrates the step by step procedure adopted at a soap manufacturing company to improve the Quality by reducing process variability using Statistical Process Control.

  1. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product...

  2. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of...

  3. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in...

  4. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which...

  5. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a statisti

  6. The influence of organizational culture on the use of quality techniques and its impact on performance

    DEFF Research Database (Denmark)

    Gambi, Lillian; Jørgensen, Frances; Boer, Harry

    2013-01-01

    This report presents the results of a study about the influence of organizational culture on quality techniques and the impact of matching culture and technique to enhance performance. Data were drawn from 250 manufacturing companies in Brazil and Denmark. Profiles were identified according...... to the companies’ cultural characteristics and use of quality techniques. Findings suggest: 1- Certain cultural profiles predict the use of certain quality techniques better than others. For example, companies with a group culture, which is oriented towards collaboration and development of human resources, tend...... to use goal setting and continuous improvement techniques, rather than measurement techniques. In turn, companies that have a rational or hierarchical culture, which are oriented towards control and competition, tend to use measurement techniques more than cultures oriented to collaboration or creation...

  7. Quality Control of EUVE Databases

    Science.gov (United States)

    John, Linda M.

    1993-01-01

    The publicly accessible databases for the Extreme Ultraviolet Explorer (EUVE) include: the EUVE Archive Mailserver, the Center for EUV Astrophysics ftp site, the EUVE Guest Observer Mailserver, and the Astronomical Data System node. The EUVE Performance Assurance team is responsible for verifying that these public databases are working properly and that the public availability of EUVE data contained therein does not infringe any data rights which may have been assigned. In this paper, we describe the quality assurance (QA) procedures we have developed from approaching QA as a service organization; this approach reflects the overall EUVE philosophy of QA integrated into normal operating procedures, rather than imposed as an external, post-facto, control mechanism.

  8. Application of ultrasonic technique in nondestructive food quality analysis: a review

    Science.gov (United States)

    Quality control and safe storage is important in food processing and storage. Composition of food has more effect on quality in terms of nutritional values, functional properties, commercial values and storage conditions of the food products. Traditional analytical techniques that are used for compo...

  9. Myoelectric Control Techniques for a Rehabilitation Robot

    Directory of Open Access Journals (Sweden)

    Alan Smith

    2011-01-01

    Full Text Available This work examines two different types of myoelectric control schemes for the purpose of rehabilitation robot applications. The first is a commonly used technique based on a Gaussian classifier. It is implemented in real time for healthy subjects in addition to a subject with Central Cord Syndrome (CCS. The myoelectric control scheme is used to control three degrees of freedom (DOF on a robot manipulator which corresponded to the robot's elbow joint, wrist joint, and gripper. The classes of motion controlled include elbow flexion and extension, wrist pronation and supination, hand grasping and releasing, and rest. Healthy subjects were able to achieve 90% accuracy. Single DOF controllers were first tested on the subject with CCS and he achieved 100%, 96%, and 85% accuracy for the elbow, gripper, and wrist controllers respectively. Secondly, he was able to control the three DOF controller at 68% accuracy. The potential applications for this scheme are rehabilitation and teleoperation. To overcome limitations in the pattern recognition based scheme, a second myoelectric control scheme is also presented which is trained using electromyographic (EMG data derived from natural reaching motions in the sagittal plane. This second scheme is based on a time delayed neural network (TDNN which has the ability to control multiple DOF at once. The controller tracked a subject's elbow and shoulder joints in the sagittal plane. Results showed an average error of 19° for the two joints. This myoelectric control scheme has the potential of being used in the development of exoskeleton and orthotic rehabilitation applications.

  10. Industrial applications of advanced control techniques

    Institute of Scientific and Technical Information of China (English)

    刘国平

    2003-01-01

    This paper discusses two industrial control applications using advanced control techniques. They are theoptimal-tuning nonlinear PID control of hydraulic systems and the neural predictive control of combustor acoustic ofgas turbines. For hydraulic control systems, an optimal PID controller with inverse of dead zone is introduced toovercome the dead zone and is designed to satisfy desired time-domain performance requirements. Using the adaptivemodel, an optimal-tuning PID control scheme is proposed to provide optimal PID parameters even in the case wherethe system dynamics is time variant. For combustor acoustic control of gas turbines, a neural predictive controlstrategy is presented, which consists of three parts: an output model, output predictor and feedback controller. Theoutput model of the combustor acoustic is established using neural networks to predict the output and overcome thetime delay of the system, which is often very large, compared with the sampling period. The output-feedback con-troller is introduced which uses the output of the predictor to suppress instability in the combustion process. The a-bove control strategies are implemented in the SIMULINK/dSPACE controller development environment. Theirperformance is evaluated on the industrial hydraulic test rig and the industrial combustor test rig.

  11. Fallout radionuclide-based techniques for assessing the impact of soil conservation measures on erosion control and soil quality: an overview of the main lessons learnt under an FAO/IAEA Coordinated Research Project.

    Science.gov (United States)

    Dercon, G; Mabit, L; Hancock, G; Nguyen, M L; Dornhofer, P; Bacchi, O O S; Benmansour, M; Bernard, C; Froehlich, W; Golosov, V N; Haciyakupoglu, S; Hai, P S; Klik, A; Li, Y; Lobb, D A; Onda, Y; Popa, N; Rafiq, M; Ritchie, J C; Schuller, P; Shakhashiro, A; Wallbrink, P; Walling, D E; Zapata, F; Zhang, X

    2012-05-01

    This paper summarizes key findings and identifies the main lessons learnt from a 5-year (2002-2008) coordinated research project (CRP) on "Assessing the effectiveness of soil conservation measures for sustainable watershed management and crop production using fallout radionuclides" (D1.50.08), organized and funded by the International Atomic Energy Agency through the Joint FAO/IAEA Division of Nuclear Techniques in Food and Agriculture. The project brought together nineteen participants, from Australia, Austria, Brazil, Canada, Chile, China, Japan, Morocco, Pakistan, Poland, Romania, Russian Federation, Turkey, United Kingdom, United States of America and Vietnam, involved in the use of nuclear techniques and, more particularly, fallout radionuclides (FRN) to assess the relative impacts of different soil conservation measures on soil erosion and land productivity. The overall objective of the CRP was to develop improved land use and management strategies for sustainable watershed management through effective soil erosion control practices, by the use of ¹³⁷Cs (half-life of 30.2 years), ²¹⁰Pb(ex) (half-life of 22.3 years) and ⁷Be (half-life of 53.4 days) for measuring soil erosion over several spatial and temporal scales. The environmental conditions under which the different research teams applied the tools based on the use of fallout radionuclides varied considerably--a variety of climates, soils, topographies and land uses. Nevertheless, the achievements of the CRP, as reflected in this overview paper, demonstrate that fallout radionuclide-based techniques are powerful tools to assess soil erosion/deposition at several spatial and temporal scales in a wide range of environments, and offer potential to monitor soil quality. The success of the CRP has stimulated an interest in many IAEA Member States in the use of these methodologies to identify factors and practices that can enhance sustainable agriculture and minimize land degradation.

  12. Multidisciplinary Techniques and Novel Aircraft Control Systems

    Science.gov (United States)

    Padula, Sharon L.; Rogers, James L.; Raney, David L.

    2000-01-01

    The Aircraft Morphing Program at NASA Langley Research Center explores opportunities to improve airframe designs with smart technologies. Two elements of this basic research program are multidisciplinary design optimization (MDO) and advanced flow control. This paper describes examples where MDO techniques such as sensitivity analysis, automatic differentiation, and genetic algorithms contribute to the design of novel control systems. In the test case, the design and use of distributed shape-change devices to provide low-rate maneuvering capability for a tailless aircraft is considered. The ability of MDO to add value to control system development is illustrated using results from several years of research funded by the Aircraft Morphing Program.

  13. Information Quality Control of ERP System

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    From the viewpoint of manufacturing enterprises, th is thesis discusses the concept and definition of information quality as well as t he connotation of information quality. Based on our personal experiences of many years, we have summarized the cases of success and failure with ERP system, an d from the angle of information quality control, we have come up with the follow ing concepts : static information quality of enterprises, information maturity o f enterprises and dynamic information quality.Inform...

  14. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  15. MAIN PROBLEMS OF CONTROLLING OF THE QUALITY

    Directory of Open Access Journals (Sweden)

    Orlov A. I.

    2015-09-01

    Full Text Available Controlling of statistical methods to ensure product quality is the special case of controlling organizational and economic methods of management. Today, controlling in the practice of management of Russian companies is understood as "the system of information-analytical and methodological support to achieve their goals." The controller is developing a decision-making rules, the head takes decisions on the basis of these rules. We proved the concept of "controlling of methods". Innovation in management is based, in particular, on the use of new adequate organizational-economic (as well as economicmathematical and statistical methods. Controlling in this area - is the development and application procedures of compliance management used and newly developed (implemented organizationaleconomic methods for the task. Thus, the methodology for controlling is of great practical value in any field in which the actions (operations must be carried out in accordance with certain rules (regulations, standards, guidelines, as in any such area in which we need to use development and application procedures of compliance management used and the newly established (implemented rules for solution of tasks assigned to the organization. In this article, we select a area of controlling as controlling quality, and we discuss its main issues. This is about controlling of organizational-economic methods to ensure product quality, especially about the statistical methods based on probability theory and mathematical statistics. We consider the analysis and synthesis of plans of statistical quality control, optimization options plans of statistical control, truncated plans. Are discussed the differences control plans provider and the consumer, the allocation of units formless (liquid, gas products, the selection of a random sample of the statistical quality control of products, lower estimate of the required sample size. It is established, that is not always necessary

  16. [The Raman Spectroscopy (RS): A new tool for the analytical quality control of injectable in health settings. Comparison of RS technique versus HPLC and UV/Vis-FTIR, applied to anthracyclines as anticancer drugs].

    Science.gov (United States)

    Bourget, P; Amin, A; Moriceau, A; Cassard, B; Vidal, F; Clement, R

    2012-12-01

    The study compares the performances of three analytical methods devoted to Analytical Quality Control (AQC) of therapeutic solutions formed into care environment, we are talking about Therapeutics Objects(TN) (TOs(TN)). We explored the pharmacological model of two widely used anthracyclines i.e. adriamycin and epirubicin. We compared the performance of the HPLC versus two vibrational spectroscopic techniques: a tandem UV/Vis-FTIR on one hand and Raman Spectroscopy (RS) on the other. The three methods give good results for the key criteria of repeatability, of reproducibility and, of accuracy. A Spearman and a Kendall correlation test confirms the noninferiority of the vibrational techniques as an alternative to the reference method (HPLC). The selection of bands for characterization and quantification by RS is the results of a gradual process adjustment, at the intercept of matrix effects. From the perspective of a AQC associated to release of TOs, RS displays various advantages: (a) to decide quickly (~2min), simultaneously and without intrusion or withdrawal on both the nature of a packaging than on a solvant and this, regardless of the compound of interest; it is the founder asset of the method, (b) to explore qualitatively and quantitatively any kinds of TOs, (c) operator safety is guaranteed during production and in the laboratory, (d) the suppression of analytical releases or waste contribute to protects the environment, (e) the suppression.of consumables, (f) a negligible costs of maintenance, (g) a small budget of technicians training. These results already show that the SR technology is potentially a strong contributor to the safety of the medication cycle and fight against the iatrogenic effects of drugs. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  17. Quality control parameters for Tamra (copper) Bhasma.

    Science.gov (United States)

    Jagtap, Chandrashekhar Yuvaraj; Prajapati, Pradeepkumar; Patgiri, Biswajyoti; Shukla, Vinay J

    2012-04-01

    Metallic Bhasmas are highly valued and have their own importance in Ayurvedic formulations. To testify the Bhasmas various parameters have been told in Rasashastra classics. Tamra Bhasma (TB) with its different properties is used in the treatment of various diseases is quiet famous among the Ayurvedic physicians (Vaidyas). The present study was carried out to set up the quality control parameters for the TB by making the use of classical tests along with advanced analytical tools. Copper wire taken for the preparation of Bhasma was first analyzed for its copper content and then subjected to Shodhana, Marana and Amrutikarana procedures as per the classical references. Final product complied with all the classical parameters like Rekhapurnatwa, Varitaratwa etc. After complying with these tests TB was analyzed by advanced analytical techniques like particle size distribution (PSD) analysis, scanning electron microscopy (SEM), and inductive coupled plasma spectrometry (ICP). PSD analysis of TB showed volumetric mean diameter of 28.70 μm, 50% of the material was below 18.40 μm size. Particle size less than 2μm were seen in SEM. 56.24 wt % of copper and 23.06 wt % of sulphur was found in ICP-AES. Heavy metals like cadmium, selenium were not detected while others like arsenic, lead and mercury were present in traces. These observations could be specified as the quality control parameters conforming to all the classical tests under the Bhasma Pariksha.

  18. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  19. Colorado Air Quality Control Regulations and Ambient Air Quality Standards.

    Science.gov (United States)

    Colorado State Dept. of Health, Denver. Div. of Air Pollution Control.

    Regulations and standards relative to air quality control in Colorado are defined in this publication. Presented first are definitions of terms, a statement of intent, and general provisions applicable to all emission control regulations adopted by the Colorado Air Pollution Control Commission. Following this, three regulations are enumerated: (1)…

  20. Association between product quality control and process quality control of bulk milk

    OpenAIRE

    Velthuis, A.; Asseldonk, van, M.M.L.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a statistical analysis was conducted. The analysis comprised 64.373 audit results on 26,953 dairy farms and all conducted lab tests of bulk-milk samples two, six or 12 months before the audit. Lab results in...

  1. Meat quality evaluation by hyperspectral imaging technique: an overview.

    Science.gov (United States)

    Elmasry, Gamal; Barbin, Douglas F; Sun, Da-Wen; Allen, Paul

    2012-01-01

    During the last two decades, a number of methods have been developed to objectively measure meat quality attributes. Hyperspectral imaging technique as one of these methods has been regarded as a smart and promising analytical tool for analyses conducted in research and industries. Recently there has been a renewed interest in using hyperspectral imaging in quality evaluation of different food products. The main inducement for developing the hyperspectral imaging system is to integrate both spectroscopy and imaging techniques in one system to make direct identification of different components and their spatial distribution in the tested product. By combining spatial and spectral details together, hyperspectral imaging has proved to be a promising technology for objective meat quality evaluation. The literature presented in this paper clearly reveals that hyperspectral imaging approaches have a huge potential for gaining rapid information about the chemical structure and related physical properties of all types of meat. In addition to its ability for effectively quantifying and characterizing quality attributes of some important visual features of meat such as color, quality grade, marbling, maturity, and texture, it is able to measure multiple chemical constituents simultaneously without monotonous sample preparation. Although this technology has not yet been sufficiently exploited in meat process and quality assessment, its potential is promising. Developing a quality evaluation system based on hyperspectral imaging technology to assess the meat quality parameters and to ensure its authentication would bring economical benefits to the meat industry by increasing consumer confidence in the quality of the meat products. This paper provides a detailed overview of the recently developed approaches and latest research efforts exerted in hyperspectral imaging technology developed for evaluating the quality of different meat products and the possibility of its widespread

  2. Quality Control in Production Processes

    Directory of Open Access Journals (Sweden)

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  3. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  4. Utility of the molecular biology techniques to the analytical control of the microbiological quality of waters; Utilidad de las tecnicas de biologia molecular para el control analitico de la calidad microbiologica de las aguas

    Energy Technology Data Exchange (ETDEWEB)

    Codony, F.; Martin Perez, L.; Morato, J.; Dominguez Gual, M. C.

    2009-07-01

    The molecular biology techniques made accessible to the water industry the ability to detect and quantify, in a few hours, any organism known. given this scenario, it is important to realize the strengths and weaknesses of these techniques to get a better picture of the scope of its implementation and its most that probably usefulness. We must be familiar with these techniques to understand the results and properly evaluate its detection limit. (Author) 4 refs.

  5. Handling qualities requirements for control configured vehicles

    Science.gov (United States)

    Woodcock, R. J.; George, F. L.

    1976-01-01

    The potential effects of fly by wire and control configured vehicle concepts on flying qualities are considered. Failure mode probabilities and consequences, controllability, and dynamics of highly augmented aircraft are among the factors discussed in terms of design criteria.

  6. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  7. 7 CFR 981.442 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.442 Section 981.442 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Administrative Rules and Regulations § 981.442 Quality control. (a) Incoming. Pursuant to § 981.42(a),...

  8. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6...

  9. Sensometrics for Food Quality Control

    DEFF Research Database (Denmark)

    Brockhoff, Per B.

    2011-01-01

    The industrial development of innovative and succesful food items and the measuring of food quality in general is difficult without actually letting human beings evaluate the products using their senses at some point in the process. The use of humans as measurement instruments calls for special...

  10. Beam Techniques - Beam Control and Manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Minty, Michiko G

    2003-04-24

    We describe commonly used strategies for the control of charged particle beams and the manipulation of their properties. Emphasis is placed on relativistic beams in linear accelerators and storage rings. After a brief review of linear optics, we discuss basic and advanced beam control techniques, such as transverse and longitudinal lattice diagnostics, matching, orbit correction and steering, beam-based alignment, and linac emittance preservation. A variety of methods for the manipulation of particle beam properties are also presented, for instance, bunch length and energy compression, bunch rotation, changes to the damping partition number, and beam collimation. The different procedures are illustrated by examples from various accelerators. Special topics include injection and extraction methods, beam cooling, spin transport and polarization.

  11. Construction of Control Charts Using Fuzzy Multinomial Quality

    OpenAIRE

    2008-01-01

    Control charts are the simplest type of on-line statistical process control techniques. One of the basic control charts is P-chart. In classical P-charts, each item classifies as either "nonconforming" or "conforming" to the specification with respect to the quality characteristic. In practice, one may classify each item in more than two categories such as "bad", "medium", "good", and "excellent". Based on this, we introduce a fuzzy multinomial chart ( FM-chart) for monitoring a multinomial p...

  12. DATA ANALYSIS TECHNIQUES IN SERVICE QUALITY LITERATURE: ESSENTIALS AND ADVANCES

    Directory of Open Access Journals (Sweden)

    Mohammed naved Khan

    2013-05-01

    Full Text Available Academic and business researchers have for long debated on the most appropriate data analysis techniques that can be employed in conducting empirical researches in the domain of services marketing. On the basis of an exhaustive review of literature, the present paper attempts to provide a concise and schematic portrayal of generally followed data analysis techniques in the field of services quality literature. Collectively, the extant literature suggests that there is a growing trend among researchers to rely on higher order multivariate techniques viz. confirmatory factor analysis, structural equation modeling etc. to generate and analyze complex models, while at times ignoring very basic and yet powerful procedures such as mean, t-Test, ANOVA and correlation. The marked shift in orientation of researchers towards using sophisticated analytical techniques can largely beattributed to the competition within the community of researchers in social sciences in general and those working in the area of service quality in particular as also growing demands of reviewers ofjournals. From a pragmatic viewpoint, it is expected that the paper will serve as a useful source of information and provide deeper insights to academic researchers, consultants, and practitionersinterested in modelling patterns of service quality and arriving at optimal solutions to increasingly complex management problems.

  13. Advances in quality control for dioxins monitoring and evaluation of measurement uncertainty from quality control data.

    Science.gov (United States)

    Eppe, Gauthier; De Pauw, Edwin

    2009-08-01

    This paper describes an application of multivariate and multilevel quality control charts with the aim of improving the internal quality control (IQC) procedures for the monitoring of dioxins and dioxin-like PCBs analysis in food. Dioxin analysts have to use the toxic equivalent concept (TEQ) to assess the toxicity potential of a mixture of dioxin-like compounds. The TEQ approach requires quantifying individually 29 dioxin-like compounds. Monitoring the congeners separately on univariate QC charts is misleading owing to the increase of false alarm rate. We propose to subdivide the TEQ value into 3 sub-groups and to control simultaneously the 3 variables in a T(2) chart. When a T(2) exceeds the upper control limit, it acts as a warning to trigger additional investigations on individual congeners. We discuss the minimum number of runs required to reliably estimate the QC chart parameters and we suggest using data from multilevel QC charts to properly characterize the standard deviations and the correlation coefficients. Moreover, the univariate QC chart can be sensitised to detect systematic errors by using exponentially weighted moving average (EWMA) technique. The EWMA chart provides an additional guidance on setting appropriate criteria to control the method bias and to support trend analysis. Finally, we present an estimate of measurement uncertainty by computing the accuracy profile in a retrospective way with the QC data generated and we discuss assessment of compliance with regulatory maximum levels.

  14. Water quality assessment in Kelantan delta using remote sensing technique

    Science.gov (United States)

    Syahreza, S.; MatJafri, M. Z.; Lim, H. S.; Mustapha, M. R.

    2012-09-01

    This paper presents the utilities of remote sensing technique for water quality assessment in Kelantan Delta, Malaysia. Remote sensing is one of the effective methods for water quality monitoring through image analysis of study area. Spectral reflectance signatures of Kelantan Delta were measured from 20 stations using ASD Handheld spectroradiometer from regions with different turbidity level. Water samples collected from these stations were taken to the laboratory for measure turbidity in Nephelometric Turbidity Unit (NTU). The objective of this study is to examine the potential of ALOS on Japanese Earth Observing Satellite (JEOS) for assessing water quality in Kelantan Delta. There is a large correlation between NTU and the in-situ reflectance at 500 - 620 nm (maximum spectra band between 300 and 1100 nm) is shown by multiple linier regression model, resulting from increasing of turbidity levels, was developed and applied to ALOS band 2 and band 3 (0.42-069 nm). A simple atmospheric correction, based on darkest pixel technique was performed in this study. The ALOS data provides accurate estimates of the mean water quality (R2 = 0.95 and RMSE = 2.26 NTU). The result acquired is reliable to estimate of water quality values for the Kelantan Delta and its implication for future operation.

  15. Balancing Training Techniques for Flight Controller Certification

    Science.gov (United States)

    Gosling, Christina

    2011-01-01

    Training of ground control teams has been a difficult task in space operations. There are several intangible skills that must be learned to become the steely eyed men and women of mission control who respond to spacecraft failures that can lead to loss of vehicle or crew if handled improperly. And as difficult as training is, it can also be costly. Every day, month or year an operator is in training, is a day that not only they are being trained without direct benefit to the organization, but potentially an instructor or mentor is also being paid for hours spent assisting them. Therefore, optimization of the training flow is highly desired. Recently the Expedition Division (DI) at Johnson Space Flight Center has recreated their training flows for the purpose of both moving to an operator/specialist/instructor hierarchy and to address past inefficiencies in the training flow. This paper will discuss the types of training DI is utilizing in their new flows, and the balance that has been struck between the ideal learning environments and realistic constraints. Specifically, the past training flow for the ISS Attitude Determination and Control Officer will be presented, including drawbacks that were encountered. Then the new training flow will be discussed and how a new approach utilizes more training methods and teaching techniques. We will look at how DI has integrated classes, workshops, checkouts, module reviews, scenarios, OJT, paper sims, Mini Sims, and finally Integrated Sims to balance the cost and timing of training a new flight controller.

  16. Flying qualities criteria and flight control design

    Science.gov (United States)

    Berry, D. T.

    1981-01-01

    Despite the application of sophisticated design methodology, newly introduced aircraft continue to suffer from basic flying qualities deficiencies. Two recent meetings, the DOD/NASA Workshop on Highly Augmented Aircraft Criteria and the NASA Dryden Flight Research Center/Air Force Flight Test Center/AIAA Pilot Induced Oscillation Workshop, addressed this problem. An overview of these meetings is provided from the point of view of the relationship between flying qualities criteria and flight control system design. Among the items discussed are flying qualities criteria development, the role of simulation, and communication between flying qualities specialists and control system designers.

  17. Effectiveness of applying progressive muscle relaxation technique on quality of life of patients with multiple sclerosis.

    Science.gov (United States)

    Ghafari, Somayeh; Ahmadi, Fazlolah; Nabavi, Masoud; Anoshirvan, Kazemnejad; Memarian, Robabe; Rafatbakhsh, Mohamad

    2009-08-01

    To identify the effects of applying Progressive Muscle Relaxation Technique on Quality of Life of patients with multiple Sclerosis. In view of the growing caring options in Multiple Sclerosis, improvement of quality of life has become increasingly relevant as a caring intervention. Complementary therapies are widely used by multiple sclerosis patients and Progressive Muscle Relaxation Technique is a form of complementary therapies. Quasi-experimental study. Multiple Sclerosis patients (n = 66) were selected with no probability sampling then assigned to experimental and control groups (33 patients in each group). Means of data collection included: Individual Information Questionnaire, SF-8 Health Survey, Self-reported checklist. PMRT performed for 63 sessions by experimental group during two months but no intervention was done for control group. Statistical analysis was done by SPSS software. Student t-test showed that there was no significant difference between two groups in mean scores of health-related quality of life before the study but this test showed a significant difference between two groups, one and two months after intervention (p Relaxation Technique on quality of life of multiple sclerosis patients, further research is required to determine better methods to promote quality of life of patients suffer multiple sclerosis and other chronic disease. Progressive Muscle Relaxation Technique is practically feasible and is associated with increase of life quality of multiple sclerosis patients; so that health professionals need to update their knowledge about complementary therapies.

  18. Quality control for quantitative geophysical logging

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Kyu; Hwang, Se Ho; Hwang, Hak Soo; Park, In Hwa [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    Despite the great availability of geophysical data obtained from boreholes, the interpretation is subject to significant uncertainties. More accurate data with less statistical uncertainties should require an employment of more quantitative techniques in log acquisition and interpretation technique. The long-term objective of this project is the development of techniques in both quality control of log measurement and the quantitative interpretation. In the first year, the goals of the project will include establishing the procedure of log acquisition using various tests, analysing the effect of logging velocity change on the logging data, examining the repeatability and reproducibility, analyzing of filtering effect on the log measurements, and finally the zonation and the correlation of single-and inter-well log data. For the establishment of logging procedure, we have tested the multiple factors affecting the accuracy in depth. The factors are divided into two parts: human and mechanical. These factors include the zero setting of depth, the calculation of offset for the sonde, the stretching effect of cable, and measuring wheel accuracy. We conclude that the error in depth setting results primarily from human factor, and also in part from the stretching of cable. The statistical fluctuation of log measurements increases according to increasing the logging speed for the zone of lower natural gamma. Thus, the problem related with logging speed is a trifling matter in case of the application of resources exploration, the logging speed should run more slowly to reduce the statistical fluctuation of natural gamma with lithologic correlation in mind. The repeatability and reproducibility of logging measurements are tested. The results of repeatability test for the natural gamma sonde are qualitatively acceptable in the reproducibility test, the errors occurs in logging data between two operators and successive trials. We conclude that the errors result from the

  19. Automated RNA Sample Quality Control

    OpenAIRE

    Borg, Solange; Salowsky, Ruediger; Inche, Adam; Connelly, Matthew; Boland, Dierdre; Padmanabanv, Arunkumar; Graf, Eva; Liu, Melissa Huang

    2014-01-01

    The Agilent 2200 TapeStation system provides a flexible solution for automated analysis of up to 96 samples using pre-packaged reagents and minimal manual handling. Here we present a new assay – the RNA ScreenTape assay – to enable robust quantification and quality analysis of Total RNA samples from both eukaryotic and prokaryotic sources from 100 pg/μl to 500 ng/μl. The new assay additionally benefits from the ability to provide separation of contaminant genomic DNA allowing more accurate pu...

  20. Quality Control Charts in Large-Scale Assessment Programs

    Science.gov (United States)

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  1. Quality Control Charts in Large-Scale Assessment Programs

    Science.gov (United States)

    Schafer, William D.; Coverdale, Bradley J.; Luxenberg, Harlan; Jin, Ying

    2011-01-01

    There are relatively few examples of quantitative approaches to quality control in educational assessment and accountability contexts. Among the several techniques that are used in other fields, Shewart charts have been found in a few instances to be applicable in educational settings. This paper describes Shewart charts and gives examples of how…

  2. Use of Stewart Control Chart Technique in Monitoring Student Performance

    Directory of Open Access Journals (Sweden)

    A.A. Akinrefon

    2014-12-01

    Full Text Available Students' academic performance was assessed using quality control techniques. Results show that performance of students was out of control using mean chart (X ̅-Chart with Central Limit (CL = 2.35, Upper Control Limit (UCL = 3.20 (although grade points above this limit may not necessarily be regarded as out-of-control-points for academic performance and Lower Control Limit (LCL = 1.51. Similarly, students' performance was also found not to be in control using Standard Deviation (S-Chart with Central Limit (CL = 0.71, Upper Control Limit = 1.34, Lower Control Limit = 0.001 approximately.The chart shows point falling below lower control limit (1.51; that is, students with poor performance. This can be adopted as a bench mark for assessing whether or not students should proceed to the next academic level, some sort of 'Academic Good-Standing'. Above the upper control limit are exceptional/ good results. The average performance of students is 2.35 which corresponds to third class grade; this implies that on average, students graduate with third class.

  3. Quality Management techniques embedded in Agile Project Development

    Directory of Open Access Journals (Sweden)

    Dovleac Raluca

    2017-01-01

    Full Text Available It used to be hard to make your dream come true and start a business but now, thanks to the dotcom boom and the rapid development of emerging technologies everybody has the chance to become the next Steve Jobs. Quality management tools and creativity techniques gave birth to the startup trend that transforms a brilliant idea into an innovative product. A common practice amongst startups is Agile development. In this paper, after analyzing the Agile approach and the tools used to ensure quality for every stage of a product’s development life cycle and the results of using the Agile approach looking out for advantages and short comings as well, we proposed a PDCA inspired tool which embeds both quality and creativity techniques to help developers ensure quality for each stage of a product’s life cycle as well as help them better organize their activities to reach the desired goals. We validated this approach by implementing it to the case of the Vitraly startup.

  4. Flying qualities - A costly lapse in flight-control design

    Science.gov (United States)

    Berry, D. T.

    1982-01-01

    Generic problems in advanced aircraft with advanced control systems which suffer from control sensitivity, sluggish response, and pilot-induced oscillation tendencies are examined, with a view to improving techniques for eliminating the problems in the design phase. Results of two NASA and NASA/AIAA workshops reached a consensus that flying qualities criteria do not match control system development, control system designers are not relying on past experience in their field, ground-based simulation is relied on too heavily, and communications between flying qualities and control systems engineers need improvement. A summation is offered in that hardware and software have outstripped the pilot's capacity to use the capabilities which new aircraft offer. The flying qualities data base is stressed to be dynamic, and continually redefining the man/machine relationships.

  5. Development of Evaluation Technique of GMAW Welding Quality Based on Statistical Analysis

    Institute of Scientific and Technical Information of China (English)

    FENG Shengqiang; TERASAKI Hidenri; KOMIZO Yuichi; HU Shengsun; CHEN Donggao; MA Zhihua

    2014-01-01

    Nondestructive techniques for appraising gas metal arc welding(GMAW) faults plays a very important role in on-line quality controllability and prediction of the GMAW process. On-line welding quality controllability and prediction have several disadvantages such as high cost, low efficiency, complication and greatly being affected by the environment. An enhanced, efficient evaluation technique for evaluating welding faults based on Mahalanobis distance(MD) and normal distribution is presented. In addition, a new piece of equipment, designated the weld quality tester(WQT), is developed based on the proposed evaluation technique. MD is superior to other multidimensional distances such as Euclidean distance because the covariance matrix used for calculating MD takes into account correlations in the data and scaling. The values of MD obtained from welding current and arc voltage are assumed to follow a normal distribution. The normal distribution has two parameters: the meanm and standard deviations of the data. In the proposed evaluation technique used by the WQT, values of MD located in the range from zero tom+3s are regarded as “good”. Two experiments which involve changing the flow of shielding gas and smearing paint on the surface of the substrate are conducted in order to verify the sensitivity of the proposed evaluation technique and the feasibility of using WQT. The experimental results demonstrate the usefulness of the WQT for evaluating welding quality. The proposed technique can be applied to implement the on-line welding quality controllability and prediction, which is of great importance to design some novel equipment for weld quality detection.

  6. An Unified Approach for Process Quality Analysis and Control

    Directory of Open Access Journals (Sweden)

    Prof.Chandrakanth Biradar,Aruna Kawdi

    2012-09-01

    Full Text Available Abstract— The process in a company finally results in product of the company, which represents the company standard. Hence, during the process execution time quality of the process needs to be taken care before and after the work done. In this paper, an unified approach to quality analysis and control of a process development is presented. This approach gives an overview of what the task the company assigned to the employers. The process is defined as the set of action items to achieve the work completion. Quality means grade of excellence. Quality analysis of a process is an improvement of the process and making sure that all the standard procedures are followed. An unified approach designed in this paper is a combination of software cost estimation and a financial market forecasting with the support of historical data, statistical data mining technique and artificial neural networks, which helps the developers as well as investors in strategic planning and investment decision making. Therefore, the paper describes a recommended process to develop software (SW cost estimates for software managers, perform financial market forecasting to control quality of process development. As a result, the improvement and analysis of the process quality can be performed from basic level to the corporate level. By this work, we conclude that the process quality control can be made easier and efficient compared to the old graphical analytics technique.

  7. Net analyte signal based statistical quality control

    NARCIS (Netherlands)

    Skibsted, E.T.S.; Boelens, H.F.M.; Westerhuis, J.A.; Smilde, A.K.; Broad, N.W.; Rees, D.R.; Witte, D.T.

    2005-01-01

    Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is sep

  8. Quality or Control? Management in Higher Education

    Science.gov (United States)

    Milliken, John; Colohan, Gerry

    2004-01-01

    Over the past fifteen years the rationale, organisational infrastructure and delivery of social policy in Britain have undergone radical transformation. Whereas efficiency was the key word of the 1980s, quality was the touchstone of the 1990s and quality control with accountability has become the management philosophy of the new millennium.…

  9. RANKINGTHEREFACTORING TECHNIQUES BASED ON THE INTERNAL QUALITY ATTRIBUTES

    Directory of Open Access Journals (Sweden)

    Sultan Alshehri

    2014-01-01

    Full Text Available The analytic hierarchy process (AHP has been applied in many fields and especially to complex engineering problems and applications. The AHP is capable of structuring decision problems and finding mathematically determined judgments built on knowledge and experience. This suggests that AHP should prove useful in agile software development where complex decisions occur routinely. In this paper, the AHP is used to rank the refactoring techniques based on the internal code quality attributes. XP encourages applying the refactoring where the code smells bad. However, refactoring may consume more time and efforts.So, to maximize the benefits of the refactoring in less time and effort, AHP has been applied to achieve this purpose. It was found that ranking the refactoring techniques helped the XP team to focus on the technique that improve the code and the XP development process in general.

  10. Quality control of seasonal influenza vaccines.

    Science.gov (United States)

    Mandušić Nazor, Tamara; Pipić Kosanović, Marta; Tomić, Siniša

    2010-12-01

    The purpose of seasonal influenza vaccination is to prevent its spread. The vaccines contain strains of the influenza virus recommended and approved for a particular season. Just like any other medicinal product, all vaccines require marketing approval. Batches of approved vaccines are extensively tested by the manufacturers and additionally controlled by the approving authorities, which issue the quality control certificates. This article not only to describes the legal background of quality control, but also how control test results obtained by a Croatian official control laboratory are compared to manufacturer's results. We have found that testing results can slightly differ depending on methods/analytical procedures used in different laboratories. This investigation has also shown how important it is to test finished medicinal products, independently of testing at intermediate stages, and how retesting by control authorities ensures that marketed vaccines meet quality standards.

  11. Quality Control Guidelines for SAM Chemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the chemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  12. Quality Control Guidelines for SAM Biotoxin Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the pathogen methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  13. Quality Control Guidelines for SAM Radiochemical Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the radiochemistry methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  14. Quality Control Guidelines for SAM Pathogen Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the biotoxin methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  15. Quality Control Approaches for Chinese Herbal Medicines

    Institute of Scientific and Technical Information of China (English)

    YUAN Hai-long; ZHANG Tian-tian; XIAO Xiao-he

    2011-01-01

    The current official quality control approaches meet the challenges from the complexity of herbal medicines.In fact,any herbal medicines containing numerous unknown components,its curative effect usually depends on the whole of herbal medicines,so it is impossible and unnecessary to qualitatively and quantitatively study every component.By investigating the limitations of current quality control approaches for herbal medicines and the difference and similarity in the chemical substantial style as well as quality control pattern of herbal medicines,a new quality control approach for Chinese herbal medicines should be explored and designed.The combination approach of chemical analysis with bioassay is promising to be developed and employed in order to ensure the safety and efficacy of Chinese herbal medicines.

  16. Quality Controlled Local Climatological Data (QCLCD) Publication

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Quality Controlled Local Climatological Data (QCLCD) contains summaries from major airport weather stations that include a daily account of temperature extremes,...

  17. Eddy current quality control of soldered current-carrying busbar splices of superconducting magnets

    CERN Document Server

    Kogan, L; Savary, F; Principe, R; Datskov, V; Rozenfel'd, E; Khudjakov, B

    2015-01-01

    The eddy current technique associated with a U-shaped transducer is studied for the quality control of soldered joints between superconducting busbars ('splices'). Two other quality control techniques, based on X-rays and direct measurement of the electrical resistance, are also studied for comparison. A comparative analysis of the advantages and disadvantages of these three methods in relation to the quality control of soldered superconducting busbar cables enclosed in copper shells is used for benchmarking. The results of inspections with the U-shaped eddy current transducer carried out on several sample joints presenting different types of soldering defects show the potential of this type of nondestructive (ND) quality control technique.

  18. High quality 2D crystals made by anodic bonding: a general technique for layered materials.

    Science.gov (United States)

    Gacem, Karim; Boukhicha, Mohamed; Chen, Zhesheng; Shukla, Abhay

    2012-12-21

    Anodic bonding of nanolayers is an easy technique based on a simple apparatus, which has already proven successful in application in the fabrication of high quality graphene. Here we demonstrate its extension to the fabrication of high quality nanolayers from several layered materials. The strengths of this technique are its high throughput rate and ease of application. All fabrication parameters are controllable and need to be determined carefully. We report optimal parameters found for nine layered materials. In general, using optimal parameters results in high quality 2D layers, in most cases much larger than those obtained by 'Scotch tape' microcleavage, with higher yields and which are easily transferable to other substrates. Moreover the samples obtained are clean and the good optical contrast of these layers on the glass substrate makes their identification very easy. This is thus the technique of choice for making nanolayers in the laboratory from any layered material.

  19. High quality 2D crystals made by anodic bonding: a general technique for layered materials

    Science.gov (United States)

    Gacem, Karim; Boukhicha, Mohamed; Chen, Zhesheng; Shukla, Abhay

    2012-12-01

    Anodic bonding of nanolayers is an easy technique based on a simple apparatus, which has already proven successful in application in the fabrication of high quality graphene. Here we demonstrate its extension to the fabrication of high quality nanolayers from several layered materials. The strengths of this technique are its high throughput rate and ease of application. All fabrication parameters are controllable and need to be determined carefully. We report optimal parameters found for nine layered materials. In general, using optimal parameters results in high quality 2D layers, in most cases much larger than those obtained by ‘Scotch tape’ microcleavage, with higher yields and which are easily transferable to other substrates. Moreover the samples obtained are clean and the good optical contrast of these layers on the glass substrate makes their identification very easy. This is thus the technique of choice for making nanolayers in the laboratory from any layered material.

  20. Precision Blasting Techniques For Avalanche Control

    Science.gov (United States)

    Powell, Kevin M.

    Experimental firings sponsored by the Center For Snow Science at Alta, Utah have demonstrated the potential of a unique prototype shaped charge device designed to stimulate snow pack and ice. These studies, conducted against stable snow pack, demonstrated a fourfold increase in crater volume yield and introduced a novel application of Shock Tube technology to facilitate position control, detonation and dud recovery of manually deployed charges. The extraordinary penetration capability of the shaped charge mechanism has been exploited in many non-military applications to meet a wide range of rapidpiercing and/or cutting requirements. The broader exploitation of the potential of the shaped charge mechanism has nevertheless remained confined to defence based applications. In the studies reported in this paper, the inimitable ability of the shaped charge mechanism to project shock energy, or a liner material, into a highly focussed energetic stream has been applied uniquely to the stimulation of snow pack. Recent research and development work, conducted within the UK, has resulted in the integration of shaped charge technology into a common Avalauncher and hand charge device. The potential of the common charge configuration and spooled Shock Tube fire and control system to improve the safety and cost effectiveness of explosives used in avalanche control operations was successfully demonstrated at Alta in March 2001. Future programmes of study will include focussed shock/blast mechanisms for suspended wire traverse techniques, application of the shaped charge mechanism to helibombing, and the desig n and development of non-fragmenting shaped charge ammunition formilitary artillery gun systems.

  1. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  2. Quality assurance and quality control in clinical cytogenetics.

    Science.gov (United States)

    Mikhail, Fady M; Watson, Michael S

    2014-07-14

    The goal of any clinical laboratory should be to provide patients with the most accurate test results possible. This is accomplished through various overlapping programs that continuously monitor and optimize all aspects of a test, including decisions by the laboratory to offer a test, the decision of providers to request the test, the testing itself, and the reporting of results to the referral source and patient. The levels at which test performance and accuracy can be optimized are encompassed under quality control (QC) and quality assurance (QA). The monitoring of QC and QA problems allows for the integration of these parameters into a total quality management program. This unit reviews QC and QA guidelines, in addition to discussing how to establish a quality assurance program.

  3. 76 FR 27622 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2011-05-12

    ... Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Large... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Large Appliance Coatings AGENCY: Environmental Protection Agency...

  4. The Use of Management Control Systems and Operations Management Techniques

    Directory of Open Access Journals (Sweden)

    Edelcio Koitiro Nisiyama

    2016-01-01

    Full Text Available It is well known that both management control systems (MCSs and operations management (OM are related to firm performance; however, an integrated st udy that involves MCS and OM within the context of firm performance is still lacking. This research aimed to examine the relationships among the use of MCSs and OM techniques and firm performance in the Brazilian auto parts industry. Simons’ levers of cont rol framework was used to characterise the uses of MCSs, and OM techniques, such as total quality management (TQM and continuous improvement programmes, were adopted. The results obtained through the structural equation modelling indicated that the diagno stic use of MCSs is positively associated with the goals of cost reduction. In addition, the interactive use of MCSs is positively associated with the objectives of introducing new products, which is consistent with previous research. Additionally, OM tech niques are positively related to cost reduction but have no direct relationship with the introduction of new products.

  5. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  6. Control techniques for invasive alien plants

    Directory of Open Access Journals (Sweden)

    Michele de Sá Dechoum

    2013-03-01

    Full Text Available Invasive alien species are recognized as a major threat to the conservation of biodiversity. These species should be managed based on local and regional environmental conditions. Control techniques were tested for ten invasive species in Santa Catarina State: the trees Casuarina equisetifolia, Hovenia dulcis, Psidium guajava, Syzygium cumini, and Terminalia catappa, and shrubs and herbs Rubus fruticosus, Furcraea foetida, Hedychium coronarium, Impatiens walleriana, and Tradescantia zebrina. Treatments applied for trees were cut stump, frill and girdling or ring-barking followed by herbicide application, while the other species were treated with foliar spray, application of herbicide on the root system, cut stump and herbicide injection. The active ingredients tested were Triclopyr, Glyphosate, and the combination of Triclopyr + Fluroxipyr in concentrations from 2 to 6%, according to the species. The cut stump method was efficient for all of the woody species, while ring-barking and frilling followed by herbicide application and basal bark application resulted in different levels of efficiency for the species tested. The most efficient method for herbs and shrubs was foliar spray, and the least efficient methods were cut stump and herbicide injection.

  7. Impact of Domain Modeling Techniques on the Quality of Domain Model: An Experiment

    Directory of Open Access Journals (Sweden)

    Hiqmat Nisa

    2016-10-01

    Full Text Available The unified modeling language (UML is widely used to analyze and design different software development artifacts in an object oriented development. Domain model is a significant artifact that models the problem domain and visually represents real world objects and relationships among them. It facilitates the comprehension process by identifying the vocabulary and key concepts of the business world. Category list technique identifies concepts and associations with the help of pre defined categories, which are important to business information systems. Whereas noun phrasing technique performs grammatical analysis of use case description to recognize concepts and associations. Both of these techniques are used for the construction of domain model, however, no empirical evidence exists that evaluates the quality of the resultant domain model constructed via these two basic techniques. A controlled experiment was performed to investigate the impact of category list and noun phrasing technique on quality of the domain model. The constructed domain model is evaluated for completeness, correctness and effort required for its design. The obtained results show that category list technique is better than noun phrasing technique for the identification of concepts as it avoids generating unnecessary elements i.e. extra concepts, associations and attributes in the domain model. The noun phrasing technique produces a comprehensive domain model and requires less effort as compared to category list. There is no statistically significant difference between both techniques in case of correctness.

  8. Impact of Domain Modeling Techniques on the Quality of Domain Model: An Experiment

    Directory of Open Access Journals (Sweden)

    Hiqmat Nisa

    2016-11-01

    Full Text Available The unified modeling language (UML is widely used to analyze and design different software development artifacts in an object oriented development. Domain model is a significant artifact that models the problem domain and visually represents real world objects and relationships among them. It facilitates the comprehension process by identifying the vocabulary and key concepts of the business world. Category list technique identifies concepts and associations with the help of pre defined categories, which are important to business information systems. Whereas noun phrasing technique performs grammatical analysis of use case description to recognize concepts and associations. Both of these techniques are used for the construction of domain model, however, no empirical evidence exists that evaluates the quality of the resultant domain model constructed via these two basic techniques. A controlled experiment was performed to investigate the impact of category list and noun phrasing technique on quality of the domain model. The constructed domain model is evaluated for completeness, correctness and effort required for its design. The obtained results show that category list technique is better than noun phrasing technique for the identification of concepts as it avoids generating unnecessary elements i.e. extra concepts, associations and attributes in the domain model. The noun phrasing technique produces a comprehensive domain model and requires less effort as compared to category list. There is no statistically significant difference between both techniques in case of correctness.

  9. Quality-of-life assessment techniques for veterinarians.

    Science.gov (United States)

    Villalobos, Alice E

    2011-05-01

    The revised veterinary oath commits the profession to the prevention and relief of animal suffering. There is a professional obligation to properly assess quality of life (QoL) and confront the issues that ruin it, such as undiagnosed suffering. There are no clinical studies in the arena of QoL assessment at the end of life for pets. This author developed a user-friendly QoL scale to help make proper assessments and decisions along the way to the conclusion of a terminal patient's life. This article discusses decision aids and establishes commonsense techniques to assess a pet's QoL.

  10. An Overview of the Quality Function Deployment (QFD) Technique

    Science.gov (United States)

    Sherif, Josef S.; Tran, Tuyet-Lan

    1995-01-01

    QFD is a product planning tool and a process methodology that enables all organizations, departments, and individuals in a business or a project to systematically focus on the critical performance, functions, and/or characteristics of a product that are the most important to the customer. It is part of the Total Quality Management (TQM) concept.. This presentation describes the objectives of QFD, the process for implementing the technique, the benefits derived from proper implementation, the kinds of systems where QFD is best utilized, what the success factors are, how QFD works, some guidelines for selection of a QFD team, and the functional roles of key team members.

  11. Power Control Technique for Efficient Call Admission Control in Advanced Wirless Networks

    Directory of Open Access Journals (Sweden)

    Ch. Sreenivasa Rao

    2012-06-01

    Full Text Available In 4G networks, call admission control techniques have been proposed to provide Quality of Service (QoS in a network by restricting the access to network resources. Power control is essential in call admission control in order to provide fair access to all users, improve battery lifetime and system performance. But the existing call admission control algorithms rarely consider the power controlling techniques in the handoff process for different traffic classes. In this paper, we propose to develop a power controlled call admission control scheme for handoff in the advanced wireless networks. The incoming call measures the initial interference on it and then the base station starts transmitting the packets to the new call. The new call is rejected when the interference reaches a threshold value.Whenever an existing call meets the power constraint, the transmit power is decremented based on thetraffic class and incoming call obtains this information by monitoring the interference received on it. Theconvergence of the power control algorithm is checked and the power levels of all incoming calls areadjusted. From our simulation results we prove that this power control technique provides efficienthandoff in the 4G networks by increasing the throughput and reducing the delay of the existing users.

  12. 75 FR 59086 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2010-09-27

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Flexible Packaging Printing AGENCY: Environmental Protection... Processes, and meets the requirement to adopt Reasonably Available Control Technology (RACT) for sources...

  13. Harmonisation Initiatives of Copernicus Data Quality Control

    Science.gov (United States)

    Vescovi, F. D.; Lankester, T.; Coleman, E.; Ottavianelli, G.

    2015-04-01

    The Copernicus Space Component Data Access system (CSCDA) incorporates data contributions from a wide range of satellite missions. Through EO data handling and distribution, CSCDA serves a set of Copernicus Services related to Land, Marine and Atmosphere Monitoring, Emergency Management and Security and Climate Change. The quality of the delivered EO products is the responsibility of each contributing mission, and the Copernicus data Quality Control (CQC) service supports and complements such data quality control activities. The mission of the CQC is to provide a service of quality assessment on the provided imagery, to support the investigation related to product quality anomalies, and to guarantee harmonisation and traceability of the quality information. In terms of product quality control, the CQC carries out analysis of representative sample products for each contributing mission as well as coordinating data quality investigation related to issues found or raised by Copernicus users. Results from the product analysis are systematically collected and the derived quality reports stored in a searchable database. The CQC service can be seen as a privileged focal point with unique comparison capacities over the data providers. The comparison among products from different missions suggests the need for a strong, common effort of harmonisation. Technical terms, definitions, metadata, file formats, processing levels, algorithms, cal/val procedures etc. are far from being homogeneous, and this may generate inconsistencies and confusion among users of EO data. The CSCDA CQC team plays a significant role in promoting harmonisation initiatives across the numerous contributing missions, so that a common effort can achieve optimal complementarity and compatibility among the EO data from multiple data providers. This effort is done in coordination with important initiatives already working towards these goals (e.g. INSPIRE directive, CEOS initiatives, OGC standards, QA4EO

  14. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  15. 30 CFR 28.31 - Quality control plans; contents.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; contents. 28.31 Section... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.31 Quality control plans; contents. (a) Each quality control plan shall contain provisions for the management of quality, including:...

  16. Frontiers in statistical quality control 11

    CERN Document Server

    Schmid, Wolfgang

    2015-01-01

    The main focus of this edited volume is on three major areas of statistical quality control: statistical process control (SPC), acceptance sampling and design of experiments. The majority of the papers deal with statistical process control, while acceptance sampling and design of experiments are also treated to a lesser extent. The book is organized into four thematic parts, with Part I addressing statistical process control. Part II is devoted to acceptance sampling. Part III covers the design of experiments, while Part IV discusses related fields. The twenty-three papers in this volume stem from The 11th International Workshop on Intelligent Statistical Quality Control, which was held in Sydney, Australia from August 20 to August 23, 2013. The event was hosted by Professor Ross Sparks, CSIRO Mathematics, Informatics and Statistics, North Ryde, Australia and was jointly organized by Professors S. Knoth, W. Schmid and Ross Sparks. The papers presented here were carefully selected and reviewed by the scientifi...

  17. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  18. Statistical quality control a loss minimization approach

    CERN Document Server

    Trietsch, Dan

    1999-01-01

    While many books on quality espouse the Taguchi loss function, they do not examine its impact on statistical quality control (SQC). But using the Taguchi loss function sheds new light on questions relating to SQC and calls for some changes. This book covers SQC in a way that conforms with the need to minimize loss. Subjects often not covered elsewhere include: (i) measurements, (ii) determining how many points to sample to obtain reliable control charts (for which purpose a new graphic tool, diffidence charts, is introduced), (iii) the connection between process capability and tolerances, (iv)

  19. HPLC for quality control of polyimides

    Science.gov (United States)

    Young, P. R.; Sykes, G. F.

    1979-01-01

    High Pressure Liquid Chromatography (HPLC) as a quality control tool for polyimide resins and prepregs are presented. A data base to help establish accept/reject criteria for these materials was developed. This work is intended to supplement, not replace, standard quality control tests normally conducted on incoming resins and prepregs. To help achieve these objectives, the HPLC separation of LARC-160 polyimide precursor resin was characterized. Room temperature resin aging effects were studied. Graphite reinforced composites made from fresh and aged resin were fabricated and tested to determine if changes observed by HPLC were significant.

  20. Uncertainty in mapping urban air quality using crowdsourcing techniques

    Science.gov (United States)

    Schneider, Philipp; Castell, Nuria; Lahoz, William; Bartonova, Alena

    2016-04-01

    Small and low-cost sensors measuring various air pollutants have become available in recent years owing to advances in sensor technology. Such sensors have significant potential for improving high-resolution mapping of air quality in the urban environment as they can be deployed in comparatively large numbers and therefore are able to provide information at unprecedented spatial detail. However, such sensor devices are subject to significant and currently little understood uncertainties that affect their usability. Not only do these devices exhibit random errors and biases of occasionally substantial magnitudes, but these errors may also shift over time. In addition, there often tends to be significant inter-sensor variability even when supposedly identical sensors from the same manufacturer are used. We need to quantify accurately these uncertainties to make proper use of the information they provide. Furthermore, when making use of the data and producing derived products such as maps, the measurement uncertainties that propagate throughout the analysis need to be clearly communicated to the scientific and non-scientific users of the map products. Based on recent experiences within the EU-funded projects CITI-SENSE and hackAIR we discuss the uncertainties along the entire processing chain when using crowdsourcing techniques for mapping urban air quality. Starting with the uncertainties exhibited by the sensors themselves, we present ways of quantifying the error characteristics of a network of low-cost microsensors and show suitable statistical metrics for summarizing them. Subsequently, we briefly present a data-fusion-based method for mapping air quality in the urban environment and illustrate how we propagate the uncertainties of the individual sensors throughout the mapping system, resulting in detailed maps that document the pixel-level uncertainty for each concentration field. Finally, we present methods for communicating the resulting spatial uncertainty

  1. Improvement of controlled pollination techniques of poplar

    Institute of Scientific and Technical Information of China (English)

    ZHOU Zhong-cheng; LIU Zong-you; HOU Kai-ju; SUN Xian-meng; ZHANG Ji-he; SHEN Bao-xian

    2008-01-01

    Over a number of years, in order to find substitutes for two traditional poplar pollination techniques: outdoor bridging trees and indoor cutting with water culture, research into two new pollination methods of uprooted outdoor seed trees and outdoor cutting branches was carried out. The advantages of two new and improved techniques were of efficiency, economy, safety and ease of operation. The methods can be applied in hybridization and breeding of poplar and other easy-to-root trees.

  2. Two applications of airtightness control techniques on big assemblies

    CERN Document Server

    Devallan, C; Marcellin, J

    1973-01-01

    Deals with two airtightness control techniques respectively applied on intersecting storage rings (ISR) at CERN in Geneva and on a liquid methane storage tank. These two big assemblies called for two different control techniques which use helium and ammonia respectively as tracer gas. Existing practical leakage detection techniques to meet industrial needs are discussed at the end of the article. (2 refs).

  3. Extracellular quality control in the epididymis

    Institute of Scientific and Technical Information of China (English)

    Gail A. Cornwall; H. Henning von Horsten; Douglas Swartz; Seethal Johnson; Kim Chau; Sandra Whelly

    2007-01-01

    The epididymal lumen represents a unique extracellular environment because of the active sperm maturation process that takes place within its confines. Although much focus has been placed on the interaction of epididymal secretory proteins with spermatozoa in the lumen, very little is known regarding how the complex epididymal milieu as a whole is maintained, including mechanisms to prevent or control proteins that may not stay in their native folded state following secretion. Because some misfolded proteins can form cytotoxic aggregate structures known as amyloid, it is likely that control/surveillance mechanisms exist within the epididymis to protect against this process and allow sperm maturation to occur. To study protein aggregation and to identify extracellular quality control mechanisms in the epididymis, we used the cystatin family of cysteine protease inhibitors, including cystatin-related epididymal spermatogenic and cystatin C as molecular models because both proteins have inherent properties to aggregate and form amyloid. In this chapter, we present a brief summary of protein aggregation by the amyloid pathway based on what is known from other organ systems and describe quality control mechanisms that exist intracellularly to control protein misfolding and aggregation. We then present a summary of our studies of cystatinrelated epididymal spermatogenic (CRES) oligomerization within the epididymal lumen, including studies suggesting that transglutaminase cross-linking may be one mechanism of extracellular quality control within the epididymis.

  4. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  5. Outsourcing University Degrees: Implications for Quality Control

    Science.gov (United States)

    Edwards, Julie; Crosling, Glenda; Edwards, Ron

    2010-01-01

    Education institutions worldwide have and continue to seek opportunities to spread their offerings abroad. While the provision of courses to students located overseas through partner institutions has many advantages, it raises questions about quality control that are not as applicable to other forms of international education. This paper uses a…

  6. 76 FR 4578 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2011-01-26

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Flat Wood Paneling Coatings AGENCY: Environmental Protection... Available Control Technology (RACT) for sources covered by EPA's Control Techniques Guidelines (CTG) for...

  7. Introducing Quality Control in the Chemistry Teaching Laboratory Using Control Charts

    Science.gov (United States)

    Schazmann, Benjamin; Regan, Fiona; Ross, Mary; Diamond, Dermot; Paull, Brett

    2009-01-01

    Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet-visible spectroscopy (UV-vis) at…

  8. Introducing Quality Control in the Chemistry Teaching Laboratory Using Control Charts

    Science.gov (United States)

    Schazmann, Benjamin; Regan, Fiona; Ross, Mary; Diamond, Dermot; Paull, Brett

    2009-01-01

    Quality control (QC) measures are less prevalent in teaching laboratories than commercial settings possibly owing to a lack of commercial incentives or teaching resources. This article focuses on the use of QC assessment in the analytical techniques of high performance liquid chromatography (HPLC) and ultraviolet-visible spectroscopy (UV-vis) at…

  9. A Study on Power Quality Improvement in PWM Controlled AC Voltage Controller

    Directory of Open Access Journals (Sweden)

    Ahmet ALTINTAŞ

    2009-04-01

    Full Text Available A lot of topologies of pulse-width modulated (PWM-AC controllers for single-phase and three-phase systems are proposed up to date. PWM-AC controllers have important advantages compared with the phase-controlled AC controllers using thyristors and triacs. The PWM-AC controller has sinusoidal current waveforms, smaller THD values, better power factor, faster dynamics, and smaller input/output filter. This article presents a novel control technique for application to PWM-AC controllers with ability of generating fewer harmonics. In the proposed control method, both the traditional AC voltage controllers and the PWM-AC controllers are combined; and smaller THD values are obtained. Thus, the harmonic pollution in the power system will be reduced; and consequently, the power quality will be increased. For this purpose, computer simulations are performed in order to investigate the proposed controller performance. The obtained results are compared with the conventional PWM-AC controller.

  10. Trends in microbial control techniques for poultry products.

    Science.gov (United States)

    Silva, Filomena; Domingues, Fernanda C; Nerín, Cristina

    2016-07-20

    Fresh poultry meat and poultry products are highly perishable foods and high potential sources of human infection due to the presence of several foodborne pathogens. Focusing on the microbial control of poultry products, the food industry generally implements numerous preventive measures based on the Hazard Analysis and Critical Control Points (HACCP) food safety management system certification together with technological steps, such as refrigeration coupled to modified atmosphere packaging that are able to control identified potential microbial hazards during food processing. However, in recent years, to meet the demand of consumers for minimally processed, high-quality, and additive-free foods, technologies are emerging associated with nonthermal microbial inactivation, such as high hydrostatic pressure, irradiation, and natural alternatives, such as biopreservation or the incorporation of natural preservatives in packaging materials. These technologies are discussed throughout this article, emphasizing their pros and cons regarding the control of poultry microbiota and their effects on poultry sensory properties. The discussion for each of the preservation techniques mentioned will be provided with as much detail as the data and studies provided in the literature for poultry meat and products allow. These new approaches, on their own, have proved to be effective against a wide range of microorganisms in poultry meat. However, since some of these emergent technologies still do not have full consumer's acceptability and, taking into consideration the hurdle technology concept for poultry processing, it is suggested that they will be used as combined treatments or, more frequently, in combination with modified atmosphere packaging.

  11. Requirements Prioritization: Challenges and Techniques for Quality Software Development

    Directory of Open Access Journals (Sweden)

    Muhammad Abdullah Awais

    2016-04-01

    Full Text Available Every organization is aware of the consequences and importance of requirements for the development of quality software product whether local or global. Requirement engineering phase of development with focus on the prioritization of requirements is going under huge research every day because in any development methodology, all requirements cannot be implemented at same time so requirements are prioritized to be implemented to give solution as early as possible in phases as scheduled in incremental fashion. Numerous frameworks and practices have been devised, in progress and some being discovered day by day. With such huge knowledge database and research available, it has always been confusing to decide which technique to follow to gain maximum results. Thus many projects fail because of the wrong choice in requirement prioritization because it’s really difficult to employ right technique and framework at right time. And problems do not end here rather due to strict deadlines, it’s often best to develop system in parts by different team members dispersed globally with diverse methodologies and differences and in this situation it becomes more difficult to prioritize requirements. Main focus would be on ETVX based prioritization [1] for in house development and requirement prioritization of software developed globally by diverse team members [2]. This paper will try to provide an overview of different prioritization techniques for software requirement, and a critical analysis of ETVX based model will be presented to highlight issues and challenges in this proposed model of requirement prioritization in [1] and improved version of this model will be presented while an analysis of requirement prioritization for software developed in global environment [2] also be presented.

  12. Development of Quality Control Procedures for Lepidoptera

    Science.gov (United States)

    Lepidopteran species are among the most destructive insect pests throughout the world. The sterile insect technique (SIT), within an area-wide integrated pest management (AW-IPM) approach, has proven to be a valuable tactic for controlling and eradicating important moth pests. Improving laboratory...

  13. Quality by control: Towards model predictive control of mammalian cell culture bioprocesses.

    Science.gov (United States)

    Sommeregger, Wolfgang; Sissolak, Bernhard; Kandra, Kulwant; von Stosch, Moritz; Mayer, Martin; Striedner, Gerald

    2017-07-01

    The industrial production of complex biopharmaceuticals using recombinant mammalian cell lines is still mainly built on a quality by testing approach, which is represented by fixed process conditions and extensive testing of the end-product. In 2004 the FDA launched the process analytical technology initiative, aiming to guide the industry towards advanced process monitoring and better understanding of how critical process parameters affect the critical quality attributes. Implementation of process analytical technology into the bio-production process enables moving from the quality by testing to a more flexible quality by design approach. The application of advanced sensor systems in combination with mathematical modelling techniques offers enhanced process understanding, allows on-line prediction of critical quality attributes and subsequently real-time product quality control. In this review opportunities and unsolved issues on the road to a successful quality by design and dynamic control implementation are discussed. A major focus is directed on the preconditions for the application of model predictive control for mammalian cell culture bioprocesses. Design of experiments providing information about the process dynamics upon parameter change, dynamic process models, on-line process state predictions and powerful software environments seem to be a prerequisite for quality by control realization. © 2017 The Authors. Biotechnology Journal published by WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. The effect of Benson's relaxation technique on the quality of sleep of Iranian hemodialysis patients: a randomized trial.

    Science.gov (United States)

    Rambod, Masoume; Pourali-Mohammadi, Nasrin; Pasyar, Nilofar; Rafii, Forough; Sharif, Farkhondeh

    2013-12-01

    This study was performed to evaluate the effectiveness of Benson's relaxation technique in the quality of sleep of hemodialysis patients. It was a randomized controlled trial with a pre-post-test design. A total of 86 hemodialysis patients referring to hemodialysis units were assigned to either the intervention (receiving Benson's relaxation technique) or the control group (routine care) through block randomization. The study was performed in two hemodialysis units affiliated to Shiraz University of Medical Sciences, Shiraz, Iran. The patients in the intervention group listened to the audiotape of Benson's relaxation technique twice a day each time for twenty minutes for eight weeks. The global score of Pittsburgh Sleep Quality Index (PSQI) as well as its components was computed in both the intervention and the control group before and at the 8th week of the intervention. The results of ANCOVA indicated significant differences between the two groups regarding the scores of Pittsburgh Sleep Quality Index subscales, such as sleep disturbance, daytime dysfunction, the use of sleep medication, and subjective sleep quality and as well as its global scores at the 8th week of the intervention (prelaxation technique in improvement of the sleep quality of the patients on hemodialysis. Thus, educational sessions are recommended to be planned on this cost effective and easy to use relaxation technique in order to improve hemodialysis patients' sleep quality. Further studies are needed to assess the effectiveness of this technique in other groups of patients. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. 42 CFR 84.41 - Quality control plans; contents.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; contents. 84.41 Section 84... AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Quality Control § 84.41 Quality control plans; contents. (a) Each quality control plan shall contain provisions for...

  16. 30 CFR 28.30 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control plans; filing requirements. 28... PROTECTION FOR TRAILING CABLES IN COAL MINES Quality Control § 28.30 Quality control plans; filing... part, each applicant shall file with MSHA a proposed quality control plan which shall be designed...

  17. 42 CFR 84.40 - Quality control plans; filing requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control plans; filing requirements. 84.40... Control § 84.40 Quality control plans; filing requirements. As a part of each application for approval or... proposed quality control plan which shall be designed to assure the quality of respiratory...

  18. 21 CFR 211.22 - Responsibilities of quality control unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Responsibilities of quality control unit. 211.22... Personnel § 211.22 Responsibilities of quality control unit. (a) There shall be a quality control unit that... have been fully investigated. The quality control unit shall be responsible for approving or...

  19. Selected applications of photothermal and photoluminescence heterodyne techniques for process control in silicon wafer manufacturing

    Science.gov (United States)

    Ehlert, Andreas; Kerstan, Michael; Lundt, Holger; Huber, Anton; Helmreich, Dieter; Geiler, Hans-Dieter; Karge, Harald; Wagner, Matthias

    1997-02-01

    Two noncontact laser-based heterodyne techniques, photothermal heterodyne (PTH) and photoluminescence heterodyne (PLH), are introduced and applied to processing and quality control in silicon wafer manufacturing. The crystallographic characteristics of process-induced defects in silicon wafers are suitable for the application of PTH and PLH techniques, which are demonstrated on selected examples from different steps of silicon wafer production. Both PLH and PTH techniques meet the demand for nondestructive and on-line-suitable measurement in the semiconductor industry.

  20. Air Quality Forecasting through Different Statistical and Artificial Intelligence Techniques

    Science.gov (United States)

    Mishra, D.; Goyal, P.

    2014-12-01

    Urban air pollution forecasting has emerged as an acute problem in recent years because there are sever environmental degradation due to increase in harmful air pollutants in the ambient atmosphere. In this study, there are different types of statistical as well as artificial intelligence techniques are used for forecasting and analysis of air pollution over Delhi urban area. These techniques are principle component analysis (PCA), multiple linear regression (MLR) and artificial neural network (ANN) and the forecasting are observed in good agreement with the observed concentrations through Central Pollution Control Board (CPCB) at different locations in Delhi. But such methods suffers from disadvantages like they provide limited accuracy as they are unable to predict the extreme points i.e. the pollution maximum and minimum cut-offs cannot be determined using such approach. Also, such methods are inefficient approach for better output forecasting. But with the advancement in technology and research, an alternative to the above traditional methods has been proposed i.e. the coupling of statistical techniques with artificial Intelligence (AI) can be used for forecasting purposes. The coupling of PCA, ANN and fuzzy logic is used for forecasting of air pollutant over Delhi urban area. The statistical measures e.g., correlation coefficient (R), normalized mean square error (NMSE), fractional bias (FB) and index of agreement (IOA) of the proposed model are observed in better agreement with the all other models. Hence, the coupling of statistical and artificial intelligence can be use for the forecasting of air pollutant over urban area.

  1. 安哥拉红土泥结石填筑施工工艺与质量控制%Construction technique and quality control of red soil mud stone filling in Angola

    Institute of Scientific and Technical Information of China (English)

    青素香

    2012-01-01

      During the construction of Industrial Park and public works in Luanda City of Angola, research was con⁃ducted to use local earth materials, so red soil mud stone was adopted to substitute cement soil and graded crushed stone for filling construction of road and storehouse foundation. An introduction was made on the technical proce⁃dures and key points of quality control.%  介绍了在安哥拉罗安达市工业园建设工程及市政工程中,结合当地材料,研究创新,用红土泥结石代替水泥土和级配碎石,填筑道路和库房场地基层的工艺流程及质量控制要点。

  2. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or... system according to the quality assurance and quality control procedures in appendix B of this part....

  3. Determination and evaluation of air quality control. Manual of ambient air quality control in Germany

    Energy Technology Data Exchange (ETDEWEB)

    Lahmann, E.

    1997-07-01

    Measurement of air pollution emissions and ambient air quality are essential instruments for air quality control. By undertaking such measurements, pollutants are registered both at their place of origin and at the place where they may have an effect on people or the environment. Both types of measurement complement each other and are essential for the implementation of air quality legislation, particularly, in compliance with emission and ambient air quality limit values. Presented here are similar accounts of measurement principles and also contains as an Appendix a list of suitability-tested measuring devices which is based on information provided by the manufacturers. In addition, the guide of ambient air quality control contains further information on discontinuous measurement methods, on measurement planning and on the assessment of ambient air quality data. (orig./SR)

  4. Técnicas de controle de qualidade utilizadas na criação de tilápia do Nilo (Oreochromis niloticus - DOI: 10.4025/actascibiolsci.v20i0.4471 Quality control techniques used in the breeding of Nile tilapia (Oreochromis niloticus - DOI: 10.4025/actascibiolsci.v20i0.4471

    Directory of Open Access Journals (Sweden)

    Júlio Hermann Leonhardt

    1998-07-01

    (LSL. By means of Pareto’s techniques and knapsack problem used, results presented the best solution for problems of predators, biometry and diseases with the maximized function Z* objective. Quality control techniques have made possible an increase of stocking rate in the tanks without a reduction of the individual growth rate and with high productions of good quality fish.

  5. Improvement on fuzzy controller design techniques

    Science.gov (United States)

    Wang, Paul P.

    1993-01-01

    This paper addresses three main issues, which are somewhat interrelated. The first issue deals with the classification or types of fuzzy controllers. Careful examination of the fuzzy controllers designed by various engineers reveals distinctive classes of fuzzy controllers. Classification is believed to be helpful from different perspectives. The second issue deals with the design according to specifications, experiments related to the tuning of fuzzy controllers, according to the specification, will be discussed. General design procedure, hopefully, can be outlined in order to ease the burden of a design engineer. The third issue deals with the simplicity and limitation of the rule-based IF-THEN logical statements. The methodology of fuzzy-constraint network is proposed here as an alternative to the design practice at present. It is our belief that predicate calculus and the first order logic possess much more expressive power.

  6. Control of Bank Consolidated Financial Statements Quality

    Directory of Open Access Journals (Sweden)

    Margarita S. Ambarchyan

    2013-01-01

    Full Text Available The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the characteristic significance factor in the process of consolidated financial statements appraisal by points. The constructed regression model is checked on accuracy and statistical significance. The model can be used by internal auditors and financial analytics as an instrument for bank and non-bank consolidated financial statements quality control

  7. Mitochondrial quality control in cardiac diseases.

    Directory of Open Access Journals (Sweden)

    Juliane Campos

    2016-10-01

    Full Text Available Disruption of mitochondrial homeostasis is a hallmark of cardiac diseases. Therefore, maintenance of mitochondrial integrity through different surveillance mechanisms is critical for cardiomyocyte survival. In this review, we discuss the most recent findings on the central role of mitochondrial quality control processes including regulation of mitochondrial redox balance, aldehyde metabolism, proteostasis, dynamics and clearance in cardiac diseases, highlighting their potential as therapeutic targets.

  8. Microbiological Quality Control of Probiotic Products

    OpenAIRE

    Astashkina, Anna Pavlovna; Khudyakova, L. I.; Kolbysheva, Yuliya Vladimirovna

    2014-01-01

    Microbiological quality control of probiotic products such as Imunele, Dannon, Pomogayka showed that they contain living cultures of the Lactobacillus Bifidobacterium genus in the amount of 107 CFU/ml, which corresponds to the number indicated on the label of products. It is identified that the survival rate of test-strains cultured with pasteurized products does not exceed 10%. The cell concentration of target-microorganisms was reduced by 20-45% after the interaction with living probiotic b...

  9. Towards quality control of food using terahertz

    Science.gov (United States)

    Ung, B. S.-Y.; Fischer, B. M.; Ng, B. W.-H.; Abbott, D.

    2007-12-01

    Terahertz radiation or T-rays, show promise in quality control of food products. As T-rays are inherently sensitive to water, they are very suitable for moisture detection. This proves to be a valuable asset in detecting the moisture content of dried food, a critical area for some products. As T-rays are transparent to plastics, food additives can also be probed through the packaging, providing checks against a manufacturer's claims, such as the presence of certain substances in foods.

  10. Quality control analytical methods: strategies to ensure a robust quality-control microbiology program.

    Science.gov (United States)

    Griffiths, Tricia; Connors, Anne

    2013-01-01

    As the regulatory environment for compounding pharmacies continues to evolve, facilities can take immediate steps to strengthen their quality-control microbiology and environmental monitoring programs. Robust programs that are timely, comprehensive, and effective will minimize risk and help support positive patient outcomes. This article provides a roadmap for putting in place a robust quality-control microbiology program in the face of United States Pharmacopeia Chapter 797 standards, and highlights several technologies for environmental monitoring that support a successful program.

  11. Advanced Control Techniques for WEC Wave Dragon

    DEFF Research Database (Denmark)

    Tedd, James; Kofoed, Jens Peter; Jasinski, M.;

    2007-01-01

    This paper presents the ongoing work on control of the Wave Dragon wave energy converter. Research is being conducted in and between several centers across Europe. This is building upon the knowledge gained in the prototype project, and will enable much better performance of the future deployment...

  12. Hydraulic Control Design and Modeling Techniques.

    Science.gov (United States)

    1989-02-01

    methodologies. This report may be difficult to read for the casual reader . It is written assuming the reader has some fundamental background in control...INTERVAL DTSMP=.O0012207 STEP=. 0012207 INDEX=INDEX+i DOUT( INDEX2)=L1 A- 4 END $*OF DISCRETE SAMP 2" DERIVATIVE tarot (INDEX2 .GE. 4098) END $*OF

  13. Simple, inexpensive technique for high-quality smartphone fundus photography in human and animal eyes.

    Science.gov (United States)

    Haddock, Luis J; Kim, David Y; Mukai, Shizuo

    2013-01-01

    Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application whose software allows for independent control of focus, exposure, and light intensity during video filming was used. With this app, we recorded high-definition videos of the fundus and subsequently extracted high-quality, still images from the video clip. Results. The described technique of smartphone fundus photography was able to capture excellent high-quality fundus images in both children under anesthesia and in awake adults. Excellent images were acquired with the 20D lens alone in the clinic, and the addition of the Koeppe lens in the operating room resulted in the best quality images. Successful photodocumentation of rabbit fundus was achieved in control and experimental eyes. Conclusion. The currently described system was able to take consistently high-quality fundus photographs in patients and in animals using readily available instruments that are portable with simple power sources. It is relatively simple to master, is relatively inexpensive, and can take advantage of the expanding mobile-telephone networks for telemedicine.

  14. Simple, Inexpensive Technique for High-Quality Smartphone Fundus Photography in Human and Animal Eyes

    Directory of Open Access Journals (Sweden)

    Luis J. Haddock

    2013-01-01

    Full Text Available Purpose. We describe in detail a relatively simple technique of fundus photography in human and rabbit eyes using a smartphone, an inexpensive app for the smartphone, and instruments that are readily available in an ophthalmic practice. Methods. Fundus images were captured with a smartphone and a 20D lens with or without a Koeppe lens. By using the coaxial light source of the phone, this system works as an indirect ophthalmoscope that creates a digital image of the fundus. The application whose software allows for independent control of focus, exposure, and light intensity during video filming was used. With this app, we recorded high-definition videos of the fundus and subsequently extracted high-quality, still images from the video clip. Results. The described technique of smartphone fundus photography was able to capture excellent high-quality fundus images in both children under anesthesia and in awake adults. Excellent images were acquired with the 20D lens alone in the clinic, and the addition of the Koeppe lens in the operating room resulted in the best quality images. Successful photodocumentation of rabbit fundus was achieved in control and experimental eyes. Conclusion. The currently described system was able to take consistently high-quality fundus photographs in patients and in animals using readily available instruments that are portable with simple power sources. It is relatively simple to master, is relatively inexpensive, and can take advantage of the expanding mobile-telephone networks for telemedicine.

  15. 7 CFR 58.335 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.335 Section 58.335... Procedures § 58.335 Quality control tests. All milk, cream and related products are subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on...

  16. 7 CFR 58.928 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.928 Section 58.928... Procedures § 58.928 Quality control tests. All dairy products and other ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall...

  17. 7 CFR 58.642 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.642 Section 58.642... Procedures § 58.642 Quality control tests. All mix ingredients shall be subject to inspection for quality and condition throughout each processing operation. Quality control tests shall be made on flow line samples...

  18. Total quality management (TQM) and the future of the environmental industry: Integration of quality tools and techniques among competing interests

    Energy Technology Data Exchange (ETDEWEB)

    Bicknell, B.A.; Bicknell, K.D. (Bicknell Consulting, Littleton, CO (United States))

    1993-01-01

    One of the most difficult problems facing industry, regulators, consultants and attorneys involved in the environmental arena is the lack of a functional method of prioritization of the seemingly unreconcilable interests of the varying entities involved in waste reduction, elimination and cleanup. This paper and presentation will address this problem by presenting methodology for problem solving that can be adopted by the competing interests to form a unified systems analysis that has enjoyed widespread use and success in both commercial business and industry, and other regulated government industries such as defense, aerospace and communication. The authors will employ specific examples of case studies with focus on hazardous waste reduction and how the quality tools and techniques commonly referred to as Total Quality Management (such as Quality Function Deployment, Experimental Design, Statistical Process Control and Functional Analysis) are and can be utilized in the process. The authors will illustrate the application of TQM techniques to areas such as process integration (e.g. implementation of the NEPA decision-making), as well as functional implementation in risk assessment, cost analysis and concurrent engineering (in the case of waste minimization technology development).

  19. Self Tuning Techniques on PLC Background and Control Systems With Self Tuning Methods Design

    Directory of Open Access Journals (Sweden)

    Jiri Koziorek

    2010-01-01

    Full Text Available Advanced Process Control techniques have become standard functions of distributed control systems. Self tuning methods belong to Advanced Process Control (APC techniques. APC techniques contain software packages for advanced control based on mathematical methods. APC tools are designed to increase the process capacity, yield and quality of products. Most of nowadays digital industry regulators and PLCs are provided with some kind of the self tuning constant algorithm. Practical part of the paper deals with design of the control systems which contain self tuning regulator. A control system with PID Self Tuner by Siemens and with visualization in WinCC is designed. There is a description of an implementation of the PID regulator as a function block which can be also used for extension control functions. Control systems for relay and moment self tuner with visualizations in WinCC are also designed.

  20. Applying GPS to check horizontal control quality

    Directory of Open Access Journals (Sweden)

    Jakub Vincent

    2004-03-01

    Full Text Available GPS technologies can also be used for check quality in available horizontal point set with coordinates CJ of the frame S-JTSK. When survey and setting-out tasks should be performed in certain area, one can found in it allways some points of the fundamental and detail state controls. To use these points for some actual aims, it is necessary to investigate their compatibility (among the point mark positions and the point coordinate of control points. This can be done using GPS surveying that may be at the same time employed to determine the new point in the relevant area.Principle of quality investigatingf an existing control is founded on determination of point coordinates CJt from GPS measurements. Then, based on discrepancies among the "official" netpoint coordinates CJ and coordinates CJt "given by GPS", it can be estimated the degree and the real compatibility dislocations in the network structure of the existing points.Realisation procedure for the introduced investigation is demonstrated on GPS checking (by SOKKIA STRATUS receivers horizontal control for reconstruction of a railway bridge on river Bodrog in East Slovakia.It can be shown from the results in Table 3, that points P3 and P7 are useless due to their incompatibility (inconsistency in the inspected point set. For other 7 points (Table 7 the average measure of incompatibility reads 9.8 mm that make possible applying these points for precise setting-out

  1. Technique for Controlling Spread of Limnotic Oncomelania

    Institute of Scientific and Technical Information of China (English)

    Li Damei(李大美); WANG Xiangsan(王祥三); LAI Yonggen

    2003-01-01

    Schistosomiasis is a parasitic disease mostly found in areas along the Changjiang River of China. The disease is spread solely through an intermediary named oncomelania, so its spread of schistosomiasis can be controlled by properly designing water intakes which prevent oncomelania from entering fanning land or residential areas. This paper reports a successful design process and a new oncomelania-free intake device. The design of the new intake is based on a sound research program in which extensive experimental studies were carried out to gain knowledge of oncomelania eco-hydraulic behavior and detailed flow field information through CFD simulation.

  2. Adaptive quality control for multimedia communications

    Directory of Open Access Journals (Sweden)

    Santichai Chuaywong

    2008-01-01

    Full Text Available Multimedia communications are communications with several types of media, such as audio, video and data. The current Internet has some levels of capability to support multimedia communications, unfortunately, the QoS (Quality of Service is still challenging. A large number of QoS mechanisms has been proposed; however, the main concern is for low levels, e.g. layer 2 (Data Link or 3 (Transport. In this paper, mechanisms for control the quality of audio and video are proposed. G.723.1 and MPEG-4 are used as the audio and video codec respectively. The proposed algorithm for adaptive quality control of audio communication is based on forward error correction (FEC. In the case of video communication, the proposed algorithm adapts the value of key frame interval, which is an encoding parameter of MPEG-4. We evaluated our proposed algorithms by computer simulation. We have shown that, in most cases, the proposed scheme gained a higher throughput compared to other schemes.

  3. FY 1995 annual report on development of techniques for creating high-quality crystalline materials for low-loss power controlling components; 1995 nendo teisonshitsu denryoku seigyo soshiyo kohinshitsu kessho zairyo sosei gijutsu kaihatsu seika hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The R and D project is implemented for manufacturing high-quality semiconductor crystalline materials of large size and uniform characteristics, in order to improve semiconductors as components for controlling power systems, and reduce power loss. The semiconductor melts, in particular silicon melt, is highly reactive, readily reacting with the atmosphere and crucible holding the melt, and it is difficult to collect their thermal properties. Therefore, an electro-magnetic levitation furnace working under a microgravity is used, to dispense with a crucible for measurement of their properties in the absence of thermal convection. The preliminary tests using the furnace produce surface tensions of the melts, because Ge is less reactive than silicon, stable in the form of a GeSbTe compound, and not wettable with Al{sub 2}O{sub 3}, MgO, SiO{sub 2} or Si{sub 3}N{sub 4}. The measurement of electric resistance of InSb indicates that InSb has characteristics of a semiconductor when it is solid and a metal when it is liquid, as is the case with Si. The program codes are developed by each researcher, and combined with each other to establish the comprehensive thermal flow analysis program, which includes all of the aspects of the internal CZ furnace structure for growing the crystals. (NEDO)

  4. Modelling and analysis of ozone concentration by artificial intelligent techniques for estimating air quality

    Science.gov (United States)

    Taylan, Osman

    2017-02-01

    High ozone concentration is an important cause of air pollution mainly due to its role in the greenhouse gas emission. Ozone is produced by photochemical processes which contain nitrogen oxides and volatile organic compounds in the lower atmospheric level. Therefore, monitoring and controlling the quality of air in the urban environment is very important due to the public health care. However, air quality prediction is a highly complex and non-linear process; usually several attributes have to be considered. Artificial intelligent (AI) techniques can be employed to monitor and evaluate the ozone concentration level. The aim of this study is to develop an Adaptive Neuro-Fuzzy inference approach (ANFIS) to determine the influence of peripheral factors on air quality and pollution which is an arising problem due to ozone level in Jeddah city. The concentration of ozone level was considered as a factor to predict the Air Quality (AQ) under the atmospheric conditions. Using Air Quality Standards of Saudi Arabia, ozone concentration level was modelled by employing certain factors such as; nitrogen oxide (NOx), atmospheric pressure, temperature, and relative humidity. Hence, an ANFIS model was developed to observe the ozone concentration level and the model performance was assessed by testing data obtained from the monitoring stations established by the General Authority of Meteorology and Environment Protection of Kingdom of Saudi Arabia. The outcomes of ANFIS model were re-assessed by fuzzy quality charts using quality specification and control limits based on US-EPA air quality standards. The results of present study show that the ANFIS model is a comprehensive approach for the estimation and assessment of ozone level and is a reliable approach to produce more genuine outcomes.

  5. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  6. Methods and Techniques of Quality Management for ICT Audit Processes

    Directory of Open Access Journals (Sweden)

    Marius Popa

    2011-09-01

    Full Text Available In modern organizations, Information and Communication Technologies are used to support the organizations’ activities. To manage the quality of the organization processes, audit processes are implemented. Also, the audit processes can aim the quality of ICT systems themselves because their involvement in organization processes. The paper investigates the ways in which a quality management can be applied for audit processes in order to obtain a high level of quality for the audit recommendations.

  7. Methods and Techniques of Quality Management for ICT Audit Processes

    CERN Document Server

    Popa, Marius

    2012-01-01

    In modern organizations, Information and Communication Technologies are used to support the organizations' activities. To manage the quality of the organization processes, audit processes are implemented. Also, the audit processes can aim the quality of ICT systems themselves because their involvement in organization processes. The paper investigates the ways in which a quality management can be applied for audit processes in order to obtain a high level of quality for the audit recommendations.

  8. Active structural control with stable fuzzy PID techniques

    CERN Document Server

    Yu, Wen

    2016-01-01

    This book presents a detailed discussion of intelligent techniques to measure the displacement of buildings when they are subjected to vibration. It shows how these techniques are used to control active devices that can reduce vibration 60–80% more effectively than widely used passive anti-seismic systems. After introducing various structural control devices and building-modeling and active structural control methods, the authors propose offset cancellation and high-pass filtering techniques to solve some common problems of building-displacement measurement using accelerometers. The most popular control algorithms in industrial settings, PD/PID controllers, are then analyzed and then combined with fuzzy compensation. The stability of this combination is proven with standard weight-training algorithms. These conditions provide explicit methods for selecting PD/PID controllers. Finally, fuzzy-logic and sliding-mode control are applied to the control of wind-induced vibration. The methods described are support...

  9. Signal sampling techniques for data acquisition in process control

    NARCIS (Netherlands)

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of

  10. Signal sampling techniques for data acquisition in process control

    OpenAIRE

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of major importance for the overall performance of a system. ... Zie: Summary

  11. Signal sampling techniques for data acquisition in process control

    NARCIS (Netherlands)

    Laan, Marten Derk van der

    1995-01-01

    In computing sytems employed for data acquisition and process control, communication with the controlled processes is mainly taking place via analog signal lines. In this situation, the quality of data acquired by A/D-converters and the generation of analog control signals by D/A-converters is of ma

  12. Construction of Control Charts Using Fuzzy Multinomial Quality

    Directory of Open Access Journals (Sweden)

    V. Amirzadeh

    2008-01-01

    Full Text Available Control charts are the simplest type of on-line statistical process control techniques. One of the basic control charts is P-chart. In classical P-charts, each item classifies as either "nonconforming" or "conforming" to the specification with respect to the quality characteristic. In practice, one may classify each item in more than two categories such as "bad", "medium", "good", and "excellent". Based on this, we introduce a fuzzy multinomial chart ( FM-chart for monitoring a multinomial process. Control limits of FM-chart are obtained by using the multinomial distribution and the degrees of membership which one assigned to the distinct categories. The comparison of the FM-chart and the -chart based on a food production process illustrates that the FM-chart leads to better results.

  13. Quality control in exascale data archives

    Science.gov (United States)

    Juckes, Martin

    2013-04-01

    Quality control of data can and should occur at many stages of the data life cycle. Data producers will generally conduct their own tests prior to release of data. Further tests may be done by within consortium projects, by archive centres or, after publication of the data, by independent investigators. The results of such tests are often used only by the individual or group carrying out the tests. Sharing of quality control information is restricted by many factors: this presentation addresses the lack of a common terminology to define quality control tests. A framework is proposed, based on abstract tests (e.g. a "prescribed range test"), specific tests (e.g. "variable tas is in the range 200-350K") and test results. Test results also need to be linked to the data robustly to ensure that they are available at all subsequent stages of the data lifecycle, and the appropriate mechanisms of linkage will differ at different stages of the lifecycle. The framework should support references to the data from the test results, references to the results from the data or discovery by association. Performing tests may generate useful by-products (e.g. the maximum and minimum values of the data): these ancillary results should be stored and made accessible with test results. In many cases tests will refer to multiple files, and groups of tests will be of more interest than individual tests. Mechanisms for describing tests suites will be discussed with particular reference to the challenges of applying tests to climate model data.

  14. [ROKO--computer-assisted roentgen quality control].

    Science.gov (United States)

    Schenk, G; Gfirtner, H

    1995-05-01

    To guarantee the quality of 30 x-ray machines and 8 photographic processors 24,000 data are collected yearly. A computer system is introduced (ROKO-Röntgenkonstanzprüfung) which helps to collect the monthly data easily and to measure on-line dose and voltage. If given tolerance values are exceeded acoustic and graphic warnings appear, a trend analysis is made to assure the correctness of the collected data, a generator to design the layout of check form facilitates the controlling and an on-line documentation for each x-ray machine is available. All these features help save time and money.

  15. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  16. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-01-01

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems. PMID:25723145

  17. Power system stabilizers based on modern control techniques

    Energy Technology Data Exchange (ETDEWEB)

    Malik, O.P.; Chen, G.P.; Zhang, Y.; El-Metwally, K. [Calgary Univ., AB (Canada). Dept. of Electrical and Computer Engineering

    1994-12-31

    Developments in digital technology have made it feasible to develop and implement improved controllers based on sophisticated control techniques. Power system stabilizers based on adaptive control, fuzzy logic and artificial networks are being developed. Each of these control techniques possesses unique features and strengths. In this paper, the relative performance of power systems stabilizers based on adaptive control, fuzzy logic and neural network, both in simulation studies and real time tests on a physical model of a power system, is presented and compared to that of a fixed parameter conventional power system stabilizer. (author) 16 refs., 45 figs., 3 tabs.

  18. Static and Dynamic Quality Assurance by Aspect Oriented Techniques

    CERN Document Server

    Knabe, Christoph

    2010-01-01

    The overall goal of the described research project was to create applicable quality assurance patterns for Java software systems using the aspect-oriented programming language extension AspectJ 5. We tried to develop aspects to check static quality criteria as a variable mutator convention and architectural layering rules. We successfully developed aspects for automating the following dynamic quality criteria: Parameterized Exception Chaining, Comfortable Declaration of Parameterized Exceptions, Not-Null Checking of Reference Variables.

  19. Development of an interventional pain management specific instrument for methodologic quality assessment of nonrandomized studies of interventional techniques.

    Science.gov (United States)

    Manchikanti, Laxmaiah; Hirsch, Joshua A; Heavner, James E; Cohen, Steven P; Benyamin, Ramsin M; Sehgal, Nalini; Falco, Frank J E; Vallejo, Ricardo; Onyewu, Obi; Zhu, Jie; Kaye, Alan D; Boswell, Mark V; Helm, Standiford; Candido, Kenneth D; Diwan, Sudhir; Simopoulos, Thomas T; Singh, Vijay; Pampati, Vidyasagar; Racz, Gabor B; Raj, P Prithvi

    2014-01-01

    The major component of a systematic review is assessment of the methodologic quality and bias of randomized and nonrandomized trials. While there are multiple instruments available to assess the methodologic quality and bias for randomized controlled trials (RCTs), there is a lack of extensively utilized instruments for observational studies, specifically for interventional pain management (IPM) techniques. Even Cochrane review criteria for randomized trials is considered not to be a "gold standard," but merely an indication of the current state of the art review methodology. Recently a specific instrument to assess the methodologic quality of randomized trials has been developed for interventional techniques. Our objective was to develop an IPM specific instrument to assess the methodological quality of nonrandomized trials or observational studies of interventional techniques. The item generation for the instrument was based on a definition of quality, to the extent to which the design and conduct of the trial were congruent with the objectives of the study. Applicability was defined as the extent to which procedures produced by the study could be applied using contemporary IPM techniques. Multiple items based on Cochrane review criteria and Interventional Pain Management Techniques - Quality Appraisal of Reliability and Risk of Bias Assessment for Nonrandomized Studies (IPM-QRBNR) were utilized. A total of 16 items were developed which formed the IPM-QRBNR tool. The assessment was performed in multiple stages. The final assessment was 4 nonrandomized studies. The inter-rater agreement was moderate to good for IPM-QRBNR criteria. Limited validity or accuracy assessment of the instrument and the large number of items to be scored were limitations. We have developed a new comprehensive instrument to assess the methodological quality of nonrandomized studies of interventional techniques. This instrument provides extensive information specific to interventional

  20. Five Librarians Talk about Quality Control and the OCLC Database.

    Science.gov (United States)

    Helge, Brian; And Others

    1987-01-01

    Five librarians considered authorities on quality cataloging in the OCLC Online Union Catalog were interviewed to obtain their views on the current level of quality control in the OCLC database, the responsibilities of OCLC and individual libraries in improving the quality of records, and the consequences of quality control problems. (CLB)

  1. 7 CFR 58.141 - Alternate quality control program.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Alternate quality control program. 58.141 Section 58... Service 1 Quality Specifications for Raw Milk § 58.141 Alternate quality control program. When a plant has in operation an acceptable quality program, at the producer level, which is approved by...

  2. Fuzzy Controller Design Using Evolutionary Techniques for Twin Rotor MIMO System: A Comparative Study

    Directory of Open Access Journals (Sweden)

    H. A. Hashim

    2015-01-01

    Full Text Available This paper presents a comparative study of fuzzy controller design for the twin rotor multi-input multioutput (MIMO system (TRMS considering most promising evolutionary techniques. These are gravitational search algorithm (GSA, particle swarm optimization (PSO, artificial bee colony (ABC, and differential evolution (DE. In this study, the gains of four fuzzy proportional derivative (PD controllers for TRMS have been optimized using the considered techniques. The optimization techniques are developed to identify the optimal control parameters for system stability enhancement, to cancel high nonlinearities in the model, to reduce the coupling effect, and to drive TRMS pitch and yaw angles into the desired tracking trajectory efficiently and accurately. The most effective technique in terms of system response due to different disturbances has been investigated. In this work, it is observed that GSA is the most effective technique in terms of solution quality and convergence speed.

  3. Quality control of laser tailor welded blanks

    Science.gov (United States)

    Yan, Qi

    2008-03-01

    Tailor welded blanks were widely used in the automobile industry for their special advantages. A combination of different materials, thickness, and coatings could be welded together to form a blank for stamping car body panels. With the gradually growing consciousness on safety requirement of auto body structural, the business of laser tailor welded blanks is developing rapidly in China. Laser tailor welded blanks were just the semi products between steel factory and automobile manufacturers. As to the laser welding defects such as convexity and concavity, automobile industry had the strict requirement. In this paper, quality standard on laser tailor welded blanks were discussed. As for the production of laser tailor welded blanks, online quality control of laser tailor welded blanks was introduced. The image processing system for welding laser positioning and weld seam monitoring were used in the production of laser tailor welded blanks. The system analyzes images from the individual cameras and transmits the results to the machine control system via a CAN bus.

  4. Quality control for invasive cardiology: Holland.

    Science.gov (United States)

    Plokker, H W

    1996-10-01

    Although no official registration of indications, treatments and results in patients with coronary heart disease has taken place in Holland, the following authorities and commissions have introduced guidelines for quality control: the Dutch government, the Dutch Society of Cardiology, the Working Group on Interventional Cardiology and the health insurers. Until 1991, the right to perform coronary interventions was tied to a license issued by the Ministry of Health. New recommendations were delineated 5 years ago: at least 500 interventions must be annually performed by 5 interventional cardiologists, i.e. ca. 100 interventions annually per cardiologist. No interventional cardiology may be performed without an in-house cardiac surgery and vice versa. In a survey by the Dutch Society of Cardiology on the quality of the Dutch centers, PTCA-mortality was ca. 0.3%, infarction rate was ca. 2%. An emergency bypass operation was necessary in 1.0 to 1.6% of the cases; the surgical team was on immediate alert for 11% of the patients. Selection of patients without risk was deemed impossible. Despite objections by some members the Dutch Society of Cardiology, it was recommended that cardiac surgery and interventions should not be separated. Data from health insurers showed no inappropriate indications for PTCA. The DUCAT-study, which used the RAND criteria, showed PTCA indications to be correct in more than 90% of the cases. The Dutch government wants to control the expansion of PTCA centers, so it is no wonder that waiting lists are becoming longer.

  5. Plastic optical fibre sensor for quality control in food industry

    Science.gov (United States)

    Novo, C.; Bilro, L.; Ferreira, R.; Alberto, N.; Antunes, P.; Leitão, C.; Nogueira, R.; Pinto, J. L.

    2013-05-01

    The present work addresses the need for new devices felt in the context of quality control, especially in the food industry. Due to the spectral dependence of the attenuation coefficient, a novel dual-parameter sensor for colour and refractive index was developed and tested. The sensor employs plastic optical fibres to measure the transmitted optical power in three measurement cells each with a different incident wavelength. The performance of the sensor was tested using several dyes at different concentrations and aqueous solutions of glycerine and ethanol. Results show that this technique allows the monitoring of refractive index and colour without cross-sensitivity.

  6. Quality Control of Biotechnological Inputs DetectingMycoplasma

    Directory of Open Access Journals (Sweden)

    Cristiane Netto

    2015-04-01

    Full Text Available The aim of this work was to study the Polymerase Chain Reaction (PCR as a tool of quality control of bovine sera and cellular cultures used in the biotechnological industry. A total of 46 samples of bovine sera derived from two slaughterhouses and 33 samples of BHK21 cells derived from two biotechnological industries were evaluated using the primers GPO-3 (sense and MGSO (antisense. The PCR technique sensibility analysis showed that 280 bp were amplified for the quantities of 50 ng to 0.006 ng of Micoplasma DNA. The primers specificity was confirmed in the test using Staphylococcus aureus, Escherichia coli, Bacillus subtilisand Candida albicans; except by the positive control, none of the samples showed amplification. The presence of Mycoplasma in bovine sera and in the cultures of BHK21 cells showed that 56.5 and 15.2%, respectively, were contaminated. Thus, it was possible to conclude that PCR was a fast and confident technique to detect mycoplasma and that it could be used to control the quality of immunobiological products and inputs, such as sera and cultures of BHK21 cells.

  7. Geographical Information System Techniques for Evaluation of Groundwater Quality

    Directory of Open Access Journals (Sweden)

    Shahram Ashraf

    2011-01-01

    Full Text Available Problem statement: The present paper tries to assess groundwater suitability for irrigation purpose in Damghan plain (5400 ha. Approach: Twenty four water samples were collected from the active wells. Parameters such as Electrical Conductivity (EC, pH, Total Dissolved Solids (TDS, were recorded in the field and major anions and cations (Ca2+, Mg2+, K+, Na+, CO32-, HCO3-, Cl-, SO42- and NO3- were analyzed in the laboratory. The data of water wells were imported into the GIS software and the different water quality maps were produced using point data. Then Suitability index of groundwater quality determined by overlaying of water quality maps. Results: Suitability index values revealed that the ground water in Amin Abad, Abdi, Abd Abad, Nasr Abad and parts of Shams Abad villages of study area had "Suitable" quality with the suitability index range between 75-100 and therefore can be used for irrigation usage. Suitability index of the groundwater in Hasnie, Gani Abad and parts of Shams Abad villages were "Moderate" quality with the range between 35-70 and Abas Abad, Abir Abad and Shaman villages had "unsuitable" quality and cannot be used for irrigation purposes. In respect of all evaluating criteria, villages of study areas that had "Suitable" and Moderate quality could safely be used for longterm irrigation purposes. Conclusion: The present study demonstrated high efficiency for GIS to analyze complex spatial data and groundwater quality suitability.

  8. Power Quality Issues and It’s Mitigation Techniques Tejashree

    Directory of Open Access Journals (Sweden)

    G. More

    2014-07-01

    Full Text Available In this paper the main power quality (PQ problems are presented with there associated causes and consequences. The economic impact associated with PQ are characterized. Also this paper tries to give the solution for reducing the losses produced because of harmonics and increasing the quality of power at consumers’ side.

  9. Application of continuous quality improvement techniques to the treatment of patients with hypertension.

    Science.gov (United States)

    Waggoner, D M

    1992-01-01

    This article reports how continuous quality improvement (CQI) techniques were applied to physician care of patients with hypertension. A physician task force at an ambulatory care center used CQI methods to address the needs of two important "customer" groups: (1) third party payors and (2) patients with hypertension. Treatment standards were defined that can also serve as a customer-oriented product description. The task force found patients' blood pressures generally well controlled. Future studies will focus on appointment making, giving advice, and the doctor's examination as subprocesses that strongly influence patient satisfaction.

  10. Improvement of Production Quality by using Six Sigma Technique:

    Directory of Open Access Journals (Sweden)

    Sawsan Ali

    2013-04-01

    Full Text Available As a result of lack of conformity of the outer diameter of the filling piston of plastic syringe to the specifications set out in the design map and the increased demand for its  products from the Medical syringes factory – Babylon. The research conducts the necessary investigations and  analysis of the production process as most of the units rejected by fact that the outer diameter of the filling piston is smaller than the minimum specification and units returned to work  due to the fact that  the outer diameter larger than the upper limit of the specification.13The research aims firstly to examine the outer diameter of the filling piston through the use of the control chart of the variables represented by the average , and its impact on the production process capability because the increase in diameter specification leads to an increase in the pressure imposed on the lining of the cylinder, causing difficulty in piston movement and a decrease in diameter specification which leads to loose the process capability to prevent leakage of fluid, causing air to enter as well as to speed the movement of the piston, which negatively affects human life in both cases. Secondly, study the possibility of improving the production process capability by using advanced levels of the sigma.The results showed that the production process in the case of a disciplined and follows a normal distribution, the pointer of  the production process capability is equal to (0.55 and the factory works within the level of Sigma equal to (1.65. The proportion of a damaged product is (15.8 % and rework (0.99 %.In order to  reduce the proportion of damaged product, this paper introduces a quality plan depending on ( ±0.025 as tolerance limits instead of ( ±0.05 to increase sigma level by 202%.

  11. ADAPTATION OF DEVELOPED TECHNIQUE OF THE METALWARE CONDITION ESTIMATION FOR THE WELDING-COVERED PARTS CONTROL

    Directory of Open Access Journals (Sweden)

    F. I. Panteleenko

    2012-01-01

    Full Text Available The technique of metalware condition estimation is worked out by authors. Questions of its adaptation to the quality assurance of restored and strengthened details and tools with the wearresistant coatings deposited are discussed. Magnetic and durometrie methods of nondestructive control used in order to estimate the exploitation reliability of details with welded coatings. Efficiency of this methods is confirmed.

  12. 46 CFR 164.019-13 - Production quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 6 2010-10-01 2010-10-01 false Production quality control requirements. 164.019-13....019-13 Production quality control requirements. (a) General. Each component manufacturer shall establish procedures for maintaining quality control of the materials used in production,...

  13. 21 CFR 640.56 - Quality control test for potency.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 7 2010-04-01 2010-04-01 false Quality control test for potency. 640.56 Section...) BIOLOGICS ADDITIONAL STANDARDS FOR HUMAN BLOOD AND BLOOD PRODUCTS Cryoprecipitate § 640.56 Quality control test for potency. (a) Quality control tests for potency of antihemophilic factor shall be...

  14. 7 CFR 275.21 - Quality control review reports.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 4 2010-01-01 2010-01-01 false Quality control review reports. 275.21 Section 275.21... Reporting on Program Performance § 275.21 Quality control review reports. (a) General. Each State agency shall submit reports on the performance of quality control reviews in accordance with the...

  15. 7 CFR 58.523 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.523 Section... Service 1 Operations and Operating Procedures § 58.523 Laboratory and quality control tests. (a) Quality control tests shall be made on samples as often as necessary to determine the shelf-life and stability...

  16. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable...

  17. 21 CFR 864.8625 - Hematology quality control mixture.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hematology quality control mixture. 864.8625 Section 864.8625 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... quality control mixture. (a) Identification. A hematology quality control mixture is a device used...

  18. 18 CFR 12.40 - Quality control programs.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Quality control... PROJECT WORKS Other Responsibilities of Applicant or Licensee § 12.40 Quality control programs. (a... meeting any requirements or standards set by the Regional Engineer. If a quality control program...

  19. Application of Time of Flight Diffraction (TOFD) Technique in Spiral Case Weld Quality Detection of Tingzikou Water Control Project%TOFD在亭子口水利枢纽电站蜗壳焊缝质量检测中的应用

    Institute of Scientific and Technical Information of China (English)

    练柳君

    2013-01-01

    The Time of Flight Diffraction (TOFD) technique can make up the deficiencies of conventional NDT methods in the detection of weld quality and effectively improve detection rate.The application of TOFD in spiral case weld quality detection of Tingzikou Water Control Project is introduced herein,and the detections of TOFD and UT are compared.The practice shows that the TOFD technique can not only improve the working condition and welding quality,but also can shorten construction period and reduce potential environmental protection risks.%超声波衍射时差法(TOFD)可以弥补常规无损检测进行焊缝质量检测时的局限性,有效提高缺陷检出率.介绍了TOFD在亭子口水利枢纽工程蜗壳焊缝质量检测中的应用,对超声波探伤和TOFD检测结果进行了比较.实践表明,TOFD技术不仅可以改善施工条件、提高焊接质量,还可以缩短工期、减少环保潜在风险.

  20. Integrated quality control architecture for multistage machining processes

    Science.gov (United States)

    Yang, Jie; Liu, Guixiong

    2010-12-01

    To solve problems concerning the process quality prediction control for the multistage machining processes, a integrated quality control architecture is proposed in this paper. First, a hierarchical multiple criteria decision model is established for the key process and the weight matrix method stratified is discussed. Predictive control of the manufacturing quality is not just for on-site monitoring and control layer, control layer in the enterprise, remote monitoring level of quality exists a variety of target predictive control demand, therefore, based on XML to achieve a unified description of manufacturing quality information, and in different source of quality information between agencies to achieve the transfer and sharing. This will predict complex global quality control, analysis and diagnosis data to lay a good foundation to achieve a more practical, open and standardized manufacturing quality with higher levels of information integration system.

  1. Data Quality Assurance Techniques for a Monitoring and Diagnosis System

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    By researching the data quality problem in the monitoring and diagnosis system (MDS),the method of detecting non-condition data based on the development trend of equipment condition is proposed, and three requirements of criteria for detecting non-condition data: dynamic, syntheses and simplicity are discussed. According to the general mode of data management in MDS, a data quality assurance system (DQAS) comprising data quality monitoring, data quality diagnosis, detection criteria adjusting and artificial confirmation is set up. A route inspection system called MTREE realizes the DQAS. Aiming at vibration data of route inspection, two detecting criteria are made. One is the quality monitoring parameter, which is found through combining and optimizing some fundamental parameters by genetic programming (GP). The other is the quality diagnosis criterion, i. e. pseudo distance of Spectral-Energy-Vector (SEV) named Adjacent J-divergence, which indicates the variation degree of adjacent data's spectral energy distribution. Results show that DQAS, including these two criteria, is effective to improve the data quality of MDS.

  2. Managing Air Quality - Control Strategies to Achieve Air Pollution Reduction

    Science.gov (United States)

    Considerations in designing an effective control strategy related to air quality, controlling pollution sources, need for regional or national controls, steps to developing a control strategy, and additional EPA resources.

  3. Control of quality in spectrometry gamma of low level

    CERN Document Server

    Salazar, A

    1997-01-01

    Low level gamma spectrometry is a very precise technique to measure the concentration of nuclides present in different samples in Bq kg sup - sup 1. The quality control of the procedure and method used can be carried out by intercomparison exercises with world recognized institutions. During the last three years the Nuclear Physics Laboratory Of The University of Costa Rica (LAFNA) has been participating in the international quality assessment program (QAP) carried out by the Environmental Measurements Laboratory (EML), department of Energy, USA. The results show a very good agreement with the rest of the participant laboratories. This provides a very objective evaluation of the high precision of the methods used by LAFNA in low level spectroscopy measurements. (Author)

  4. Scale Control and Quality Management of Printed Image Parameters

    Science.gov (United States)

    Novoselskaya, O. A.; Kolesnikov, V. L.; Solov'eva, T. V.; Nagornova, I. V.; Babluyk, E. B.; Trapeznikova, O. V.

    2017-06-01

    The article provides a comparison of the main valuation techniques for a regulated parameter of printability of the offset paper by current standards GOST 24356 and ISO 3783: 2006. The results of development and implementation of a complex test scale for management and control the quality of printed production are represented. The estimation scale is introduced. It includes normalized parameters of print optical density, print uniformity, picking out speed, the value of dot gain, print contrast with the added criteria of minimizing microtexts, a paper slip, resolution threshold and effusing ability of paper surface. The results of analysis allow directionally form surface properties of the substrate to facilitate achieving the required quality of the printed image parameters, i. e. optical density of a print at a predetermined level not less than 1.3, the print uniformity with minimal deviation of dot gain about the order of 10 per cents.

  5. IMPROVED SOFTWARE QUALITY ASSURANCE TECHNIQUES USING SAFE GROWTH MODEL

    Directory of Open Access Journals (Sweden)

    M.Sangeetha

    2010-09-01

    Full Text Available In our lives are governed by large, complex systems with increasingly complex software, and the safety, security, and reliability of these systems has become a major concern. As the software in today’ssystems grows larger, it has more defects, and these defects adversely affect the safety, security, and reliability of the systems. Software engineering is the application of a systematic, disciplined, quantifiable approach to the development, operation, andmaintenance of software. Software divides into two pieces: internal and external quality characteristics.External quality characteristics are those parts of a product that face its users, where internal quality characteristics are those that do not.Quality is conformance to product requirements and should be free. This research concerns the role of software Quality. Software reliability is an important facet of software quality. It is the probability of failure-freeoperation of a computer program in a specified environment for a specified time. In software reliability modeling, the parameters of the model are typically estimated from the test data of the corresponding component. However, the widely used point estimatorsare subject to random variations in the data, resulting in uncertainties in these estimated parameters. This research describes a new approach to the problem of software testing. The approach is based on Bayesian graphical models and presents formal mechanisms forthe logical structuring of the software testing problem, the probabilistic and statistical treatment of the uncertainties to be addressed, the test design and analysis process, and the incorporation and implication of test results. Once constructed, the models produced are dynamic representations of the software testingproblem. It explains need of the common test-and-fix software quality strategy is no longer adequate, and characterizes the properties of the quality strategy.

  6. External quality control for embryology laboratories.

    Science.gov (United States)

    Castilla, Jose Antonio; Ruiz de Assín, Rafael; Gonzalvo, Maria Carmen; Clavero, Ana; Ramírez, Juan Pablo; Vergara, Francisco; Martínez, Luis

    2010-01-01

    Participation in external quality control (EQC) programmes is recommended by various scientific societies. Results from an EQC programme for embryology laboratories are presented. This 5-year programme consisted of the annual delivery of (i) materials to test toxicity and (ii) a DVD/CD-ROM with images of zygotes and embryos on days 2 and 3, on the basis of which the participants were asked to judge the embryo quality and to take a clinical decision. A high degree of agreement was considered achieved when over 75% of the laboratories produced similar classifications. With respect to the materials analysed, the specificity was 68% and the sensitivity was 83%. Concerning embryo classification, the proportion of embryos on which a high degree of agreement was achieved increased during this period from 35% to 55%. No improvement was observed in the degree of agreement on the clinical decision to be taken. Day-3 embryos produced a higher degree of agreement (58%) than did day-2 embryos (32%) (Pembryology laboratories.

  7. Semantic Entity-Component State Management Techniques to Enhance Software Quality for Multimodal VR-Systems.

    Science.gov (United States)

    Fischbach, Martin; Wiebusch, Dennis; Latoschik, Marc Erich

    2017-04-01

    Modularity, modifiability, reusability, and API usability are important software qualities that determine the maintainability of software architectures. Virtual, Augmented, and Mixed Reality (VR, AR, MR) systems, modern computer games, as well as interactive human-robot systems often include various dedicated input-, output-, and processing subsystems. These subsystems collectively maintain a real-time simulation of a coherent application state. The resulting interdependencies between individual state representations, mutual state access, overall synchronization, and flow of control implies a conceptual close coupling whereas software quality asks for a decoupling to develop maintainable solutions. This article presents five semantics-based software techniques that address this contradiction: Semantic grounding, code from semantics, grounded actions, semantic queries, and decoupling by semantics. These techniques are applied to extend the well-established entity-component-system (ECS) pattern to overcome some of this pattern's deficits with respect to the implied state access. A walk-through of central implementation aspects of a multimodal (speech and gesture) VR-interface is used to highlight the techniques' benefits. This use-case is chosen as a prototypical example of complex architectures with multiple interacting subsystems found in many VR, AR and MR architectures. Finally, implementation hints are given, lessons learned regarding maintainability pointed-out, and performance implications discussed.

  8. Quality Improvement of Liver Ultrasound Images Using Fuzzy Techniques

    Science.gov (United States)

    Bayani, Azadeh; Langarizadeh, Mostafa; Radmard, Amir Reza; Nejad, Ahmadreza Farzaneh

    2016-01-01

    Background: Liver ultrasound images are so common and are applied so often to diagnose diffuse liver diseases like fatty liver. However, the low quality of such images makes it difficult to analyze them and diagnose diseases. The purpose of this study, therefore, is to improve the contrast and quality of liver ultrasound images. Methods: In this study, a number of image contrast enhancement algorithms which are based on fuzzy logic were applied to liver ultrasound images - in which the view of kidney is observable - using Matlab2013b to improve the image contrast and quality which has a fuzzy definition; just like image contrast improvement algorithms using a fuzzy intensification operator, contrast improvement algorithms applying fuzzy image histogram hyperbolization, and contrast improvement algorithms by fuzzy IF-THEN rules. Results: With the measurement of Mean Squared Error and Peak Signal to Noise Ratio obtained from different images, fuzzy methods provided better results, and their implementation - compared with histogram equalization method - led both to the improvement of contrast and visual quality of images and to the improvement of liver segmentation algorithms results in images. Conclusion: Comparison of the four algorithms revealed the power of fuzzy logic in improving image contrast compared with traditional image processing algorithms. Moreover, contrast improvement algorithm based on a fuzzy intensification operator was selected as the strongest algorithm considering the measured indicators. This method can also be used in future studies on other ultrasound images for quality improvement and other image processing and analysis applications. PMID:28077898

  9. Quality Improvement of Liver Ultrasound Images Using Fuzzy Techniques.

    Science.gov (United States)

    Bayani, Azadeh; Langarizadeh, Mostafa; Radmard, Amir Reza; Nejad, Ahmadreza Farzaneh

    2016-12-01

    Liver ultrasound images are so common and are applied so often to diagnose diffuse liver diseases like fatty liver. However, the low quality of such images makes it difficult to analyze them and diagnose diseases. The purpose of this study, therefore, is to improve the contrast and quality of liver ultrasound images. In this study, a number of image contrast enhancement algorithms which are based on fuzzy logic were applied to liver ultrasound images - in which the view of kidney is observable - using Matlab2013b to improve the image contrast and quality which has a fuzzy definition; just like image contrast improvement algorithms using a fuzzy intensification operator, contrast improvement algorithms applying fuzzy image histogram hyperbolization, and contrast improvement algorithms by fuzzy IF-THEN rules. With the measurement of Mean Squared Error and Peak Signal to Noise Ratio obtained from different images, fuzzy methods provided better results, and their implementation - compared with histogram equalization method - led both to the improvement of contrast and visual quality of images and to the improvement of liver segmentation algorithms results in images. Comparison of the four algorithms revealed the power of fuzzy logic in improving image contrast compared with traditional image processing algorithms. Moreover, contrast improvement algorithm based on a fuzzy intensification operator was selected as the strongest algorithm considering the measured indicators. This method can also be used in future studies on other ultrasound images for quality improvement and other image processing and analysis applications.

  10. A Total Quality-Control Plan with Right-Sized Statistical Quality-Control.

    Science.gov (United States)

    Westgard, James O

    2017-03-01

    A new Clinical Laboratory Improvement Amendments option for risk-based quality-control (QC) plans became effective in January, 2016. Called an Individualized QC Plan, this option requires the laboratory to perform a risk assessment, develop a QC plan, and implement a QC program to monitor ongoing performance of the QC plan. Difficulties in performing a risk assessment may limit validity of an Individualized QC Plan. A better alternative is to develop a Total QC Plan including a right-sized statistical QC procedure to detect medically important errors. Westgard Sigma Rules provides a simple way to select the right control rules and the right number of control measurements.

  11. Chapter 5: Quality assurance/quality control in stormwater sampling

    Science.gov (United States)

    Sampling the quality of stormwater presents unique challenges because stormwater flow is relatively short-lived with drastic variability. Furthermore, storm events often occur with little advance warning, outside conventional work hours, and under adverse weather conditions. Therefore, most stormwat...

  12. Quality Test Template toward Multi-user Access Control of Internet-Based System

    Directory of Open Access Journals (Sweden)

    Nan Nie

    2011-06-01

    Full Text Available Aiming at three kinds of Internet-based system quality problems, which is performance, liability and security, the paper proposes a kind of test template during multi-user login and resource access control, which includes test requirement, login script, role-resource correlating and mutation test technique. Some Internet-based systems are tested and diagnosed by automation test technique of test template. At last, system quality can be verified and improved through the realization mechanism of test template.

  13. Rapid and quantitative quality control of microarrays using cationic nanoparticles.

    Science.gov (United States)

    Sun, Ye; Fan, Wenhua; McCann, Michael P; Golovlev, Val

    2009-02-15

    The fabrication quality of microarrays significantly influences the accuracy and reproducibility of microarray experiments. In this report, we present a simple and fast quality control (QC) method for spotted oligonucleotide and cDNA microarrays. It employs a nonspecific electrostatic interaction of colloidal gold nanoparticles with the chemical groups of DNA molecules and other biomolecules immobilized on the microarray surface that bear positive or negative charges. An inexpensive flatbed scanner is used to visualize and quantify the binding of cationic gold particles to the anionic DNA probes on the microarray surface. An image analysis software was designed to assess the various parameters of the array spots including spot intensity, shape and array homogeneity, calculate the overall array quality score, and save the detailed array quality report in an Excel file. The gold staining technique is fast and sensitive. It can be completed in 10 min and detect less than 1% of the probe amount commonly recommended for microarrays. Compared to the current microarray QC method that utilizes the hybridization of probes with short random sequence oligonucleotides labeled with fluorophore, our gold staining method requires less time for the analysis, reduces the reagent cost, and eliminates the need for the expensive laser scanner.

  14. Active vibration control techniques for flexible space structures

    Science.gov (United States)

    Parlos, Alexander G.; Jayasuriya, Suhada

    1990-01-01

    Two proposed control system design techniques for active vibration control in flexible space structures are detailed. Control issues relevant only to flexible-body dynamics are addressed, whereas no attempt was made to integrate the flexible and rigid-body spacecraft dynamics. Both of the proposed approaches revealed encouraging results; however, further investigation of the interaction of the flexible and rigid-body dynamics is warranted.

  15. Influence of diagnostic quality scanning technique with CR mammography; Influencia de la tecnica de exploracion en la calidad diagnostica de la mamografia ocn CR

    Energy Technology Data Exchange (ETDEWEB)

    Rivas Ballarin, M. A.; Ruiz Manzano, P.; Ortega Pardina, P.; Laliena Bielsa, V.; Calvo Carrillo, S.; Garcia Romero, A.; Millan Cebrian, E.

    2013-07-01

    Image quality criteria laid down in the Spanish Protocol of Control of quality in Radiology (PECCR) to a team of mammography with CR imaging system are applied in this work and evaluated the dosimetry impact implied by the modification of the technique of exposure required for the fulfilment of those criteria. Is also analyzes the impact on the image quality of the new radiographic technique, evaluated by three radiologists. (Author)

  16. Geocoding coronial data: tools and techniques to improve data quality.

    Science.gov (United States)

    Freestone, Darren; Williamson, Dianne; Wollersheim, Dennis

    2012-01-01

    Clinical, administrative and demographic health information is fundamental to understanding the nature of health and evaluating the effectiveness of efforts to reduce morbidity and mortality of the population. The demographic data item 'location' is an integral part of any injury surveillance tool or injury prevention strategy. The true value of location data can only be realised once these data have been appropriately classified and quality assured. Geocoding as a means of classifying location is increasingly used in various health fields to enable spatial analysis of data. This article reports on research carried out in Australia at the National Coroners Information System (NCIS). Trends in the use of NCIS location-based data by researchers were identified. The research also aimed to establish the factors that impacted on the quality of geocoded data and the extent of this impact. A systematic analysis of the geocoding process identified source documentation, data cleaning, and software settings as key factors impacting on data quality. Understanding and application of these processes can improve data quality and therefore inform the analysis and interpretation of these data by researchers.

  17. Nonlinear control techniques for an atomic force microscope system

    Institute of Scientific and Technical Information of China (English)

    Yongchun FANG; Matthew FEEMSTER; Darren DAWSON; Nader M.JALILI

    2005-01-01

    Two nonlinear control techniques are proposed for an atomic force microscope system.Initially,a learning-based control algorithm is developed for the microcantilever-sample system that achieves asymptotic cantilever tip tracking for periodic trajectories.Specifically,the control approach utilizes a learning-based feedforward term to compensate for periodic dynamics and high-gain terms to account for non-periodic dynamics.An adaptive control algorithm is then developed to achieve asymptotic cantilever tip tracking for bounded tip trajectories despite uncertainty throughout the system parameters.Simulation results are provided to illustrate the efficacy and performance of the control strategies.

  18. Sliding mode control of switching power converters techniques and implementation

    CERN Document Server

    Tan, Siew-Chong; Tse, Chi-Kong

    2011-01-01

    Sliding Mode Control of Switching Power Converters: Techniques and Implementation is perhaps the first in-depth account of how sliding mode controllers can be practically engineered to optimize control of power converters. A complete understanding of this process is timely and necessary, as the electronics industry moves toward the use of renewable energy sources and widely varying loads that can be adequately supported only by power converters using nonlinear controllers.Of the various advanced control methods used to handle the complex requirements of power conversion systems, sliding mode c

  19. Engine control techniques to account for fuel effects

    Science.gov (United States)

    Kumar, Shankar; Frazier, Timothy R.; Stanton, Donald W.; Xu, Yi; Bunting, Bruce G.; Wolf, Leslie R.

    2014-08-26

    A technique for engine control to account for fuel effects including providing an internal combustion engine and a controller to regulate operation thereof, the engine being operable to combust a fuel to produce an exhaust gas; establishing a plurality of fuel property inputs; establishing a plurality of engine performance inputs; generating engine control information as a function of the fuel property inputs and the engine performance inputs; and accessing the engine control information with the controller to regulate at least one engine operating parameter.

  20. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality...

  1. Evolutionary biology and genetic techniques for insect control

    OpenAIRE

    Leftwich, Philip; Bolton, Michael; Chapman, Tracey

    2015-01-01

    Abstract The requirement to develop new techniques for insect control that minimize negative environmental impacts has never been more pressing. Here we discuss population suppression and population replacement technologies. These include sterile insect technique, genetic elimination methods such as the release of insects carrying a dominant lethal (RIDL), and gene driving mechanisms offered by intracellular bacteria and homing endonucleases. We also review the potential of newer or underutil...

  2. Applying total quality management techniques to improve software development.

    Science.gov (United States)

    Mezher, T; Assem Abdul Malak, M; el-Medawar, H

    1998-01-01

    Total Quality Management (TQM) is a new management philosophy and a set of guiding principles that represent the basis of a continuously improving organization. This paper sheds light on the application of TQM concepts for software development. A fieldwork study was conducted on a Lebanese software development firm and its customers to determine the major problems affecting the organization's operation and to assess the level of adoption of TQM concepts. Detailed questionnaires were prepared and handed out to the firm's managers, programmers, and customers. The results of the study indicate many deficiencies in applying TQM concepts, especially in the areas of planning, defining customer requirements, teamwork, relationship with suppliers, and adopting standards and performance measures. One of the major consequences of these deficiencies is considerably increased programming errors and delays in delivery. Recommendations on achieving quality are discussed.

  3. Modernized Techniques for Dealing with Quality Data and Derived Products

    Science.gov (United States)

    Neiswender, C.; Miller, S. P.; Clark, D.

    2008-12-01

    "I just want a picture of the ocean floor in this area" is expressed all too often by researchers, educators, and students in the marine geosciences. As more sophisticated systems are developed to handle data collection and processing, the demand for quality data, and standardized products continues to grow. Data management is an invisible bridge between science and researchers/educators. The SIOExplorer digital library presents more than 50 years of ocean-going research. Prior to publication, all data is checked for quality using standardized criterion developed for each data stream. Despite the evolution of data formats and processing systems, SIOExplorer continues to present derived products in well- established formats. Standardized products are published for each cruise, and include a cruise report, MGD77 merged data, multi-beam flipbook, and underway profiles. Creation of these products is made possible by processing scripts, which continue to change with ever-evolving data formats. We continue to explore the potential of database-enabled creation of standardized products, such as the metadata-rich MGD77 header file. Database-enabled, automated processing produces standards-compliant metadata for each data and derived product. Metadata facilitates discovery and interpretation of published products. This descriptive information is stored both in an ASCII file, and a searchable digital library database. SIOExplorer's underlying technology allows focused search and retrieval of data and products. For example, users can initiate a search of only multi-beam data, which includes data-specific parameters. This customization is made possible with a synthesis of database, XML, and PHP technology. The combination of standardized products and digital library technology puts quality data and derived products in the hands of scientists. Interoperable systems enable distribution these published resources using technology such as web services. By developing modernized

  4. The quality control theory of aging

    Directory of Open Access Journals (Sweden)

    Warren Ladiges

    2014-05-01

    Full Text Available The quality control (QC theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1 inadequate protein processing in a distressed endoplasmic reticulum (ER; 2 histone deacetylase (HDAC processing of genomic histones and gene silencing; 3 suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4 beta-adrenergic receptor (BAR signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1 phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2 metformin, which activates AMPK and is used to treat type 2 diabetes, and 3 propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  5. QUALITY CONTROL OF SOME TRADITIONAL MEAT PRODUCTS

    Directory of Open Access Journals (Sweden)

    S. DOBRINAS

    2014-03-01

    Full Text Available In this paper, we present the characterization of six traditional meat products: smoked file, smoked bacon, pork sausages, sausage prepared from swine’s entrails, pork pastrami, sheep sausages. Organoleptic tests (the aspect and shape, the aspect of freshly cut in the section, smell, taste and consistency, physico-chemical and microbiological determinations (NTG, Salmonella, Listeria monocytogenes and Escherichia coli were performed. These analyzes are a part of quality control that must be done in order to obtain a certificate from the Ministry of Agriculture for a traditional product. After identification of H2S and starch and according to fat oxidation degree it was concluded that analyzed samples didn’t contain counterfeiters and all parameters analyzed are within the maximum limits allowed by law. Considering all the procedures for manufacturing, characteristics of raw and auxiliary materials, organoleptic properties of final products analyzed in this study, it can be concluded that analyzed meat specialties meet the requirements of Ministry Order no. 690/28.09.2004 for the traditional products certification.

  6. The quality control theory of aging.

    Science.gov (United States)

    Ladiges, Warren

    2014-01-01

    The quality control (QC) theory of aging is based on the concept that aging is the result of a reduction in QC of cellular systems designed to maintain lifelong homeostasis. Four QC systems associated with aging are 1) inadequate protein processing in a distressed endoplasmic reticulum (ER); 2) histone deacetylase (HDAC) processing of genomic histones and gene silencing; 3) suppressed AMPK nutrient sensing with inefficient energy utilization and excessive fat accumulation; and 4) beta-adrenergic receptor (BAR) signaling and environmental and emotional stress. Reprogramming these systems to maintain efficiency and prevent aging would be a rational strategy for increased lifespan and improved health. The QC theory can be tested with a pharmacological approach using three well-known and safe, FDA-approved drugs: 1) phenyl butyric acid, a chemical chaperone that enhances ER function and is also an HDAC inhibitor, 2) metformin, which activates AMPK and is used to treat type 2 diabetes, and 3) propranolol, a beta blocker which inhibits BAR signaling and is used to treat hypertension and anxiety. A critical aspect of the QC theory, then, is that aging is associated with multiple cellular systems that can be targeted with drug combinations more effectively than with single drugs. But more importantly, these drug combinations will effectively prevent, delay, or reverse chronic diseases of aging that impose such a tremendous health burden on our society.

  7. Quality control chart for crushed granite concrete

    Directory of Open Access Journals (Sweden)

    Ewa E. DESMOND

    2016-07-01

    Full Text Available A chart for assessing in-situ grade (strength of concrete, has been developed in this study. Four grades of concrete after the Nigerian General Specification for Roads and bridges (NGSRB-C20, C25, C30 and C35, is studied at different water-cement ratios for medium and high slump range. The concrete mixes are made from crushed granite rock as coarse aggregate with river sand as fine aggregate. Compression test on specimens are conducted at curing age of 1, 3, 7, 14, 21, 28 and 56 days. Results on concrete workability from slump values, and water-cement ratios revealed that specimens with lower water-cement ratio were less workable but had higher strength, compared to mixes with higher water cement ratio. A simple algorithm using nonlinear regression analysis performed on each experimental data set produced Strength-Age (S-A curves which were used to establish a quality control chart. The accuracy of these curves were evaluated by computing average absolute error (AAS, the error of estimate (EoE and the average absolute error of estimate (Abs EoE for each concrete mix. These were done based on the actual average experimental strengths to measure how close the predicted values are to the experimental data set. The absolute average error of estimate (Abs. EoE recorded was less than ±10% tolerance zone for concrete works.

  8. MITOCHONDRIA QUALITY CONTROL AND MUSCLE MASS MAINTENANCE

    Directory of Open Access Journals (Sweden)

    Vanina eRomanello

    2016-01-01

    Full Text Available Loss of muscle mass and force occurs in many diseases such as disuse/inactivity, diabetes, cancer, renal and cardiac failure and in aging-sarcopenia. In these catabolic conditions the mitochondrial content, morphology and function are greatly affected. The changes of mitochondrial network influence the production of reactive oxygen species (ROS that play an important role in muscle function. Moreover, dysfunctional mitochondria trigger catabolic signaling pathways which feed-forward to the nucleus to promote the activation of muscle atrophy. Exercise, on the other hand, improves mitochondrial function by activating mitochondrial biogenesis and mitophagy, possibly playing an important part in the beneficial effects of physical activity in several diseases. Optimised mitochondrial function is strictly maintained by the coordinated activation of different mitochondrial quality control pathways. In this review we outline the current knowledge linking mitochondria-dependent signaling pathways to muscle homeostasis in aging and disease and the resulting implications for the development of novel therapeutic approaches to prevent muscle loss.

  9. A novel technique for active vibration control, based on optimal tracking control

    Indian Academy of Sciences (India)

    BEHROUZ KHEIRI SARABI; MANU SHARMA; DAMANJEET KAUR

    2017-08-01

    In the last few decades, researchers have proposed many control techniques to suppress unwanted vibrations in a structure. In this work, a novel and simple technique is proposed for the active vibration control. In this technique, an optimal tracking control is employed to suppress vibrations in a structure by simultaneously tracking zero references for modes of vibration. To illustrate the technique, a two-degrees of freedom spring-mass-dampersystem is considered as a test system. The mathematical model of the system is derived and then converted into a state-space model. A linear quadratic tracking control law is then used to make the disturbed system track zero references.

  10. A novel technique for active vibration control, based on optimal tracking control

    Science.gov (United States)

    Kheiri Sarabi, Behrouz; Sharma, Manu; Kaur, Damanjeet

    2017-08-01

    In the last few decades, researchers have proposed many control techniques to suppress unwanted vibrations in a structure. In this work, a novel and simple technique is proposed for the active vibration control. In this technique, an optimal tracking control is employed to suppress vibrations in a structure by simultaneously tracking zero references for modes of vibration. To illustrate the technique, a two-degrees of freedom spring-mass-damper system is considered as a test system. The mathematical model of the system is derived and then converted into a state-space model. A linear quadratic tracking control law is then used to make the disturbed system track zero references.

  11. Managing Quality in Higher Education Systems via Minimal Quality Requirements: Signaling and Control.

    Science.gov (United States)

    Mizrahi, Shlomo; Mehrez, Abraham

    2002-01-01

    Discusses two versions of a signaling game to set minimal quality requirements for higher education applicants in Israel: one assumes low sensitivity to quality, the other high sensitivity. Concludes that indirect government influence on quality variations in applicant pool is more effective in controlling institutional quality then direct…

  12. Analytical approaches to quality assurance and quality control in rangeland monitoring data

    Science.gov (United States)

    Producing quality data to support land management decisions is the goal of every rangeland monitoring program. However, the results of quality assurance (QA) and quality control (QC) efforts to improve data quality are rarely reported. The purpose of QA and QC is to prevent and describe non-sampling...

  13. Quality assurance standards for purchasing and inventory control.

    Science.gov (United States)

    Soares, D P

    1985-03-01

    A process is described for quality assurance in pharmaceutical purchasing and inventory control. A quality assurance program should ensure that quality drugs are purchased at the lowest price, drug products are available when needed, the system is managed efficiently, internal controls are provided, drug products are stored under appropriate conditions, and laws, regulations, accreditation standards, and procedures are followed. To meet these objectives, product quality, vendor performance, the department's system of internal controls, purchasing data, and storage conditions should be monitored. A checklist for evaluating purchasing and inventory practices and a sample audit form listing quality assurance criteria, standards, procedures, and recommended actions are provided. A quality assurance program for pharmaceutical purchasing and inventory control should define institution-specific criteria and standards and use these standards for continual evaluation of all aspects of the purchasing and inventory control system. Documentation of quality assurance activities should be provided for use by the purchasing department, hospital administration, and regulatory bodies.

  14. Review of control techniques for inverters parallel operation

    Energy Technology Data Exchange (ETDEWEB)

    Mohd, Alaa; Ortjohann, Egon [South Westphalia University of Applied Sciences/Division Soest, Luebecker Ring 2, 59494 Soest (Germany); Morton, Danny [The University of Bolton, Deane Road, Bolton (United Kingdom); Omari, Osama (The Arab American University, Jenin, Palestine)

    2010-12-15

    This paper presents state-of-the-art review of control methods applied currently to parallel power electronic inverters. Different system architectures, their modes of operation, management and control strategies will be analyzed; advantages and disadvantages will be discussed. Though, it is not easy to give a general view at the state of the art for the research area since it is rapid and going in different directions, this paper will focus on the main streams. This paper will start by briefly reviewing the current trends in power supply systems and the increasing importance for including power electronic devices. Next, the different techniques to parallel inverters suggested in the literature will be checked. These can be categorized to the following main approaches: master/slave control techniques, current/power sharing control techniques, and frequency/voltage droop control techniques. Finally, based on the reviewed state of the art, the study concludes by comparing the different approaches reported. In addition, their weaknesses and strengths are strained. (author)

  15. Photothermal Techniques Used to Evaluate Quality in Dairy Products.

    Science.gov (United States)

    López-Romero, E.; Balderas-López, J. A.

    2017-01-01

    Photothermal systems were used to quantify thermal and optical properties of commercial and natural dairy products. Thermal diffusivity and light absorption coefficient were analyzed. It was found that water content easily alters thermal properties in samples of milk. In addition, all samples showed strong light absorptions at 405 nm, 980 nm and 488 nm, evidencing presence of proteins, fat and vitamins (riboflavin), respectively. Therefore, it was shown that thermo-physical properties measured in this work could be used as complementary parameters for quality evaluation of dairy products.

  16. Automatic Level Control for Video Cameras towards HDR Techniques

    Directory of Open Access Journals (Sweden)

    de With PeterHN

    2010-01-01

    Full Text Available We give a comprehensive overview of the complete exposure processing chain for video cameras. For each step of the automatic exposure algorithm we discuss some classical solutions and propose their improvements or give new alternatives. We start by explaining exposure metering methods, describing types of signals that are used as the scene content descriptors as well as means to utilize these descriptors. We also discuss different exposure control types used for the control of lens, integration time of the sensor, and gain control, such as a PID control, precalculated control based on the camera response function, and propose a new recursive control type that matches the underlying image formation model. Then, a description of commonly used serial control strategy for lens, sensor exposure time, and gain is presented, followed by a proposal of a new parallel control solution that integrates well with tone mapping and enhancement part of the image pipeline. Parallel control strategy enables faster and smoother control and facilitates optimally filling the dynamic range of the sensor to improve the SNR and an image contrast, while avoiding signal clipping. This is archived by the proposed special control modes used for better display and correct exposure of both low-dynamic range and high-dynamic range images. To overcome the inherited problems of limited dynamic range of capturing devices we discuss a paradigm of multiple exposure techniques. Using these techniques we can enable a correct rendering of difficult class of high-dynamic range input scenes. However, multiple exposure techniques bring several challenges, especially in the presence of motion and artificial light sources such as fluorescent lights. In particular, false colors and light-flickering problems are described. After briefly discussing some known possible solutions for the motion problem, we focus on solving the fluorescence-light problem. Thereby, we propose an algorithm for

  17. Paediatric pelvic imaging: optimisation of dose and technique using digital grid-controlled pulsed fluoroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Waugh, R.; McCarty, M. [Div. of Radiology, South Cleveland Hospital, South Tees Acute Hospitals NHS Trust, Marton Road, Middlesbrough, Cleveland (United Kingdom); McCallum, H.M. [Regional Medical Physics Dept., South Cleveland Hospital, Middlesbrough (United Kingdom); Montgomery, R. [Dept. of Orthopaedics, South Tees Hospitals NITS Trust, Middlesbrough (United Kingdom); Aszkenasy, M. [Tees and North East Yorkshire NHS Trust, West Lane Hospital, Middlesbrough (United Kingdom)

    2001-05-01

    Background. An audit of paediatric pelvic radiographs identified deficiencies in gonad shield placement and radiographic technique. Objective. A technique using grid-controlled fluoroscopy (GCF), with hard copy images in frame grab and digital spot image (DSI) format was evaluated to optimise gonad shield placement and reduce the dose given to children with Perthes disease and Developmental Hip Dysplasia (DDH) attending for pelvic radiography. Materials and methods. Phantom and patient dose surveys of conventional and fluoroscopic techniques were carried out. Image quality and radiation dose were compared for the frame grab and DSI techniques. Retrospective evaluation was undertaken to compare their clinical acceptability. Results. Both fluoroscopic techniques gave considerably less radiation than conventional non-grid radiography (67-83 %, P < 0.05). The frame grab technique gave less radiation than DSI (P < 0.05). There was no significant difference in the clinical acceptability scores of the DSI and frame grab images. Conclusion. Fluoroscopy acquired images are now used since the fluoroscopic techniques give much less dose than conventional radiography and provide images of sufficient quality for clinical assessment. Indeed, as there was no significant difference in clinical usefulness between the frame grab and DSI techniques, it is planned to use frame grab alone, thus gaining additional dose saving. (orig.)

  18. Interpolation techniques in robust constrained model predictive control

    Science.gov (United States)

    Kheawhom, Soorathep; Bumroongsri, Pornchai

    2017-05-01

    This work investigates interpolation techniques that can be employed on off-line robust constrained model predictive control for a discrete time-varying system. A sequence of feedback gains is determined by solving off-line a series of optimal control optimization problems. A sequence of nested corresponding robustly positive invariant set, which is either ellipsoidal or polyhedral set, is then constructed. At each sampling time, the smallest invariant set containing the current state is determined. If the current invariant set is the innermost set, the pre-computed gain associated with the innermost set is applied. If otherwise, a feedback gain is variable and determined by a linear interpolation of the pre-computed gains. The proposed algorithms are illustrated with case studies of a two-tank system. The simulation results showed that the proposed interpolation techniques significantly improve control performance of off-line robust model predictive control without much sacrificing on-line computational performance.

  19. 7 CFR 58.442 - Laboratory and quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Laboratory and quality control tests. 58.442 Section... Service 1 Operations and Operating Procedures § 58.442 Laboratory and quality control tests. (a) Chemical... Methods or by other methods giving equivalent results. (b) Weight or volume control....

  20. Systematic infrared image quality improvement using deep learning based techniques

    Science.gov (United States)

    Zhang, Huaizhong; Casaseca-de-la-Higuera, Pablo; Luo, Chunbo; Wang, Qi; Kitchin, Matthew; Parmley, Andrew; Monge-Alvarez, Jesus

    2016-10-01

    Infrared thermography (IRT, or thermal video) uses thermographic cameras to detect and record radiation in the longwavelength infrared range of the electromagnetic spectrum. It allows sensing environments beyond the visual perception limitations, and thus has been widely used in many civilian and military applications. Even though current thermal cameras are able to provide high resolution and bit-depth images, there are significant challenges to be addressed in specific applications such as poor contrast, low target signature resolution, etc. This paper addresses quality improvement in IRT images for object recognition. A systematic approach based on image bias correction and deep learning is proposed to increase target signature resolution and optimise the baseline quality of inputs for object recognition. Our main objective is to maximise the useful information on the object to be detected even when the number of pixels on target is adversely small. The experimental results show that our approach can significantly improve target resolution and thus helps making object recognition more efficient in automatic target detection/recognition systems (ATD/R).

  1. Improving Software Quality Prediction by Noise Filtering Techniques

    Institute of Scientific and Technical Information of China (English)

    Taghi M. Khoshgoftaar; Pierre Rebours

    2007-01-01

    Accuracy of machine learners is affected by quality of the data the learners are induced on. In this paper,quality of the training dataset is improved by removing instances detected as noisy by the Partitioning Filter. The fit datasetis first split into subsets, and different base learners are induced on each of these splits. The predictions are combined insuch a way that an instance is identified as noisy if it is misclassified by a certain number of base learners. Two versionsof the Partitioning Filter are used: Multiple-Partitioning Filter and Iterative-Partitioning Filter. The number of instancesremoved by the filters is tuned by the voting scheme of the filter and the number of iterations. The primary aim of thisstudy is to compare the predictive performances of the final models built on the filtered and the un-filtered training datasets.A case study of software measurement data of a high assurance software project is performed. It is shown that predictiveperformances of models built on the filtered fit datasets and evaluated on a noisy test dataset are generally better than thosebuilt on the noisy (un-filtered) fit dataset. However, predictive performance based on certain aggressive filters is affected bypresence of noise in the evaluation dataset.

  2. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  3. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  4. DIRECT TORQUE CONTROL FOR INDUCTION MOTOR USING INTELLIGENT TECHNIQUES

    Directory of Open Access Journals (Sweden)

    R.Toufouti

    2007-09-01

    Full Text Available In this paper, we propose two approach intelligent techniques of improvement of Direct Torque Control (DTC of Induction motor such as fuzzy logic (FL and artificial neural network (ANN, applied in switching select voltage vector .The comparison with conventional direct torque control (DTC, show that the use of the DTC_FL and DTC_ANN, reduced the torque, stator flux, and current ripples. The validity of the proposed methods is confirmed by the simulative results.

  5. Robust control design techniques for active flutter suppression

    Science.gov (United States)

    Ozbay, Hitay; Bachmann, Glen R.

    1994-01-01

    In this paper, an active flutter suppression problem is studied for a thin airfoil in unsteady aerodynamics. The mathematical model of this system is infinite dimensional because of Theodorsen's function which is irrational. Several second order approximations of Theodorsen's function are compared. A finite dimensional model is obtained from such an approximation. We use H infinity control techniques to find a robustly stabilizing controller for active flutter suppression.

  6. A control theory approach to clock steering techniques.

    Science.gov (United States)

    Farina, Marcello; Galleani, Lorenzo; Tavella, Patrizia; Bittanti, Sergio

    2010-10-01

    Several clock and time scale steering methods have been developed according to different viewpoints by various time laboratories. By resorting to control theory ideas, we propose a common theoretical framework encompassing these methods. A comparison of the most common steering methodologies, namely, the classical steering approach, the GPS bang-bang method, and the linear quadratic Gaussian technique, is carried out. We believe that the use of control theory methods can potentially lead to a better understanding of clock steering algorithms.

  7. Abstraction and control techniques for non-stationary scheduling problems

    CERN Document Server

    Innocenti, Giacomo

    2009-01-01

    The paper faces the problem of scheduling from a new perspective, trying to bridge the gap between classical heuristic approaches and system identification and control strategies. To this aim, a complete mathematical formulation of a general scheduling process is derived, beginning from very broad assumptions. This allows a greater freedom of manipulation and guarantee the resolution of the identification (and control) techniques. Both an adaptive and a switching strategies are presented in relation to the performances of a simple Round Robin algorithm.

  8. Effect of monitoring technique on quality of conservation science.

    Science.gov (United States)

    Jewell, Zoe

    2013-06-01

    Monitoring free-ranging animals in their natural habitat is a keystone of ecosystem conservation and increasingly important in the context of current rates of loss of biological diversity. Data collected from individuals of endangered species inform conservation policies. Conservation professionals assume that these data are reliable-that the animals from whom data are collected are representative of the species in their physiology, ecology, and behavior and of the populations from which they are drawn. In the last few decades, there has been an enthusiastic adoption of invasive techniques for gathering ecological and conservation data. Although these can provide impressive quantities of data, and apparent insights into animal ranges and distributions, there is increasing evidence that these techniques can result in animal welfare problems, through the wide-ranging physiological effects of acute and chronic stress and through direct or indirect injuries or compromised movement. Much less commonly, however, do conservation scientists consider the issue of how these effects may alter the behavior of individuals to the extent that the data they collect could be unreliable. The emerging literature on the immediate and longer-term effects of capture and handling indicate it can no longer be assumed that a wild animal's survival of the process implies the safety of the procedure, that the procedure is ethical, or the scientific validity of the resulting data. I argue that conservation professionals should routinely assess study populations for negative effects of their monitoring techniques and adopt noninvasive approaches for best outcomes not only for the animals, but also for conservation science.

  9. 76 FR 27610 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2011-05-12

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Large Appliance Coatings AGENCY: Environmental Protection Agency... Processes and meets the requirement to adopt Reasonably Available Control Technology (RACT) for sources...

  10. 76 FR 4534 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2011-01-26

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Flat Wood Paneling Coatings AGENCY: Environmental Protection... Processes, and meets the requirement to adopt Reasonably Available Control Technology (RACT) for sources...

  11. 76 FR 64015 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control...

    Science.gov (United States)

    2011-10-17

    ... AGENCY 40 CFR Part 52 Approval and Promulgation of Air Quality Implementation Plans; Maryland; Adoption of Control Techniques Guidelines for Drum and Pail Coatings AGENCY: Environmental Protection Agency... revision meets the requirement to adopt Reasonably Available Control Technology (RACT) for sources covered...

  12. Quality assurance and quantitative error analysis by tracer techniques

    Energy Technology Data Exchange (ETDEWEB)

    Schuetze, N.; Hermann, U.

    1983-12-01

    The locations, types and sources of casting defects have been tested by tracer techniques. Certain sites of moulds were labelled using /sup 199/Au, /sup 24/Na sodium carbonate solution, and technetium solution produced in the technetium generator on a /sup 99/Mo//sup 99/Tc elution column. Evaluations were made by means of activity measurements and autoradiography. The locations and causes of casting defects can be determined by error analysis. The surface defects of castings resulting from the moulding materials and from the blacking can be detected by technetium, the subsurface defects are located by gold.

  13. 42 CFR 84.256 - Quality control requirements.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Quality control requirements. 84.256 Section 84.256... § 84.256 Quality control requirements. (a) In addition to the construction and performance requirements specified in §§ 84.251, 84.252, 84.253, 84.254, and 84.255, the quality control requirements in...

  14. Quality control procedures in MISH-MASH systems

    Science.gov (United States)

    Szentimrey, T.; Bihari, Z.; Lakatos, M.

    2010-09-01

    The automatic quality control (QC) procedures in order to indicate or filter out the wrong data are indispensable in the databases. However the development of such software systems is impossible without adequate and advanced mathematical fundament. During the last years we developed some software systems that are MASH (Multiple Analysis of Series for Homogenization) and MISH (Meteorological Interpolation based on Surface Homogenized Data Basis), with special attention for the strong mathematical basis. The MASH system can be used for homogenization of daily and monthly series, furthermore in the system also a quality control (QC) unit has been built for the daily data. Such QC can be an essential part of the homogenization methods which are examined nowadays within the COSTES0601 HOME action. The principle of the QC procedure built in MASH is certain multiple comparisons of the data by spatial interpolation technique and the analysis of interpolation errors for detection of wrong data is based on confidence intervals. In MASH system the necessary climate statistical parameters, such as expected values, spatial and temporal covariance structure, are estimated on the basis of examined data series by classic statistical way. The reason of development of the newer MISH system was that the usual applied interpolation methods built in GIS are able to use only a single realization in time for modelling the climate statistical parameters, while in meteorology we have long data series which form a sample in time and space as well. Nowadays we plan to implement the MASH QC procedure in MISH system as well. The main modification in MISH will be that modelled statistical parameters will be used during the QC procedure but in this case the quality control can be operated also for arbitrary single observation realization in time without long data series.

  15. QUALITY CONTROL FOR EFFECTIVE BASIC EDUCATION IN

    African Journals Online (AJOL)

    Ghana 's educational system yet the system of monitoring schools is governed by an “evolving” policy. ... that schools are well supervised and that the quality of what ... quality comes from having the best equipment, the best .... performance in the classroom and their career ... the number of teachers employed and the size of.

  16. Endoplasmic reticulum quality control and apoptosis.

    Science.gov (United States)

    Groenendyk, Jody; Michalak, Marek

    2005-01-01

    The ER is one of the most important folding compartments within the cell, as well as an intracellular Ca(2+) storage organelle and it contains a number of Ca(2+) regulated molecular chaperones responsible for the proper folding of glycosylated as well as non-glycosylated proteins. The luminal environment of the ER contains Ca(2+) which is involved in regulating chaperones such as calnexin and calreticulin, as well as apoptotic proteins caspase-12 and Bap31, which may play an important role in determining cellular sensitivity to ER stress and apoptosis. The ER quality control system consists of several molecular chaperones, including calnexin, that assist in properly folding proteins and transporting them through the ER as well as sensing misfolded proteins, attempting to refold them and if this is not possible, targeting them for degradation. Accumulation of misfolded protein in the ER leads to activation of genes responsible for the expression of ER chaperones. The UPR mechanism involves transcriptional activation of chaperones by the membrane-localized transcription factor ATF6, in conjunction with the ER membrane kinase IRE1, as well as translational repression of protein synthesis by another ER membrane kinase PERK. When accumulation of misfolded protein becomes toxic, apoptosis is triggered, potentially with IRE1 involved in signaling via caspase-12. Both the extrinsic and intrinsic apoptotic pathways appear to culminate in the activation of caspases and this results in the recruitment of mitochondria in an essential amplifying manner. Bap31 may direct pro-apoptotic crosstalk between the ER and the mitochondria via Ca(2+) in conjunction with caspase-12 and calnexin. Accordingly, ER stress and the resultant Ca(2+) release must be very carefully regulated because of their effects in virtually all areas of cell function.

  17. 南水北调中线干线工程渠道逆止阀的施工工艺和质量控制%Construction Technique and Quality Control of Channel Check Valve in the Middle Route of South-to-North Water Diversion Project

    Institute of Scientific and Technical Information of China (English)

    高大勇; 朱云飞

    2013-01-01

    以南水北调鹤壁段第二施工标段为例,介绍了渠道逆止阀的安装工艺,如遵循“基础开挖→回填第一层粗砂→埋置集水暗管→回填暗管周边粗砂→铺设保温板→铺设复合土工膜→安装逆止阀”的施工流程;质量控制方法,如控制逆止阀安装位置、高程、数量等。%The installation technique of channel check valve is introduced by taking the example of Hebi section , the second construction section of South-to-North Water Diversion Project .The technique are in accordance with following orders:foundation excavation , backfilling the first layer of coarse sand , burying water collecting pipe , backfilling coarse sand surrounding pipes , laying warm keeping board , laying composite geomembrane and installing check valve .Mean-while , the quality control methods , such as control check valve installation position , elevation and quantity are also covered .

  18. Lightweight and Continuous Architectural Software Quality Assurance using the aSQA Technique

    DEFF Research Database (Denmark)

    Christensen, Henrik Bærbak; Hansen, Klaus Marius; Lindstrøm, Bo

    2010-01-01

    In this paper, we present a novel technique for assessing and prioritizing architectural quality in large-scale software development projects. The technique can be applied with relatively little effort by software architects and thus suited for agile development in which quality attributes can...... be assessed and prioritized, e.g., within each development sprint. We outline the processes and metrics embodied in the technique, and report initial experiences on the benefits and liabilities. In conclusion, the technique is considered valuable and a viable tool, and has benefits in an architectural......, technical, context, as well as in a business and people context....

  19. General Quality Control (QC) Guidelines for SAM Methods

    Science.gov (United States)

    Learn more about quality control guidelines and recommendations for the analysis of samples using the methods listed in EPA's Selected Analytical Methods for Environmental Remediation and Recovery (SAM).

  20. Cumulative sum quality control for calibrated breast density measurements

    Energy Technology Data Exchange (ETDEWEB)

    Heine, John J.; Cao Ke; Beam, Craig [Cancer Prevention and Control Division, Moffitt Cancer Center, 12902 Magnolia Drive, Tampa, Florida 33612 (United States); Division of Epidemiology and Biostatistics, School of Public Health, University of Illinois at Chicago, 1603 W. Taylor St., Chicago, Illinois 60612 (United States)

    2009-12-15

    Purpose: Breast density is a significant breast cancer risk factor. Although various methods are used to estimate breast density, there is no standard measurement for this important factor. The authors are developing a breast density standardization method for use in full field digital mammography (FFDM). The approach calibrates for interpatient acquisition technique differences. The calibration produces a normalized breast density pixel value scale. The method relies on first generating a baseline (BL) calibration dataset, which required extensive phantom imaging. Standardizing prospective mammograms with calibration data generated in the past could introduce unanticipated error in the standardized output if the calibration dataset is no longer valid. Methods: Sample points from the BL calibration dataset were imaged approximately biweekly over an extended timeframe. These serial samples were used to evaluate the BL dataset reproducibility and quantify the serial calibration accuracy. The cumulative sum (Cusum) quality control method was used to evaluate the serial sampling. Results: There is considerable drift in the serial sample points from the BL calibration dataset that is x-ray beam dependent. Systematic deviation from the BL dataset caused significant calibration errors. This system drift was not captured with routine system quality control measures. Cusum analysis indicated that the drift is a sign of system wear and eventual x-ray tube failure. Conclusions: The BL calibration dataset must be monitored and periodically updated, when necessary, to account for sustained system variations to maintain the calibration accuracy.

  1. AMAZON RAINFOREST COSMETICS: CHEMICAL APPROACH FOR QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Mariko Funasaki

    2016-02-01

    Full Text Available The market for natural cosmetics featuring ingredients derived from Amazon natural resources is growing worldwide. However, there is neither enough scientific basis nor quality control of these ingredients. This paper is an account of the chemical constituents and their biological activities of fourteen Amazonian species used in cosmetic industry, including açaí (Euterpe oleracea, andiroba (Carapa guianensis, bacuri (Platonia insignis, Brazil nut (Bertholletia excelsa, buriti (Mauritia vinifera or M. flexuosa, cumaru (Dipteryx odorata, cupuaçu (Theobroma grandiflorum, guarana (Paullinia cupana, mulateiro (Calycophyllum spruceanum, murumuru (Astrocaryum murumuru, patawa (Oenocarpus bataua or Jessenia bataua, pracaxi (Pentaclethra macroloba, rosewood (Aniba rosaeodora, and ucuuba (Virola sebifera. Based on the reviewed articles, we selected chemical markers for the quality control purpose and evaluated analytical methods. Even though chromatographic and spectroscopic methods are major analytical techniques in the studies of these species, molecular approaches will also be important as used in food and medicine traceability. Only a little phytochemical study is available about most of the Amazonian species and some species such as açaí and andiroba have many reports on chemical constituents, but studies on biological activities of isolated compounds and sampling with geographical variation are limited.

  2. Quality control in diagnostic immunohistochemistry: integrated on-slide positive controls.

    Science.gov (United States)

    Bragoni, A; Gambella, A; Pigozzi, S; Grigolini, M; Fiocca, R; Mastracci, L; Grillo, F

    2017-07-17

    Standardization in immunohistochemistry is a priority in modern pathology and requires strict quality control. Cost containment has also become fundamental and auditing of all procedures must take into account both these principles. Positive controls must be routinely performed so that their positivity guarantees the appropriateness of the immunohistochemical procedure. The aim of this study is to develop a low cost (utilizing a punch biopsy-PB-tool) procedure to construct positive controls which can be integrated in the patient's tissue slide. Sixteen frequently used control blocks were selected and multiple cylindrical samples were obtained using a 5-mm diameter punch biopsy tool, separately re-embedding them in single blocks. For each diagnostic immunoreaction requiring a positive control, an integrated PB-control section (cut from the appropriate PB-control block) was added to the top right corner of the diagnostic slide before immunostaining. This integrated control technique permitted a saving of 4.75% in total direct lab costs and proved to be technically feasible and reliable. Our proposal is easy to perform and within the reach of all pathology labs, requires easily available tools, its application costs is less than using external paired controls and ensures that a specific control for each slide is always available.

  3. Evaluation of Urban Air Quality By Passive Sampling Technique

    Science.gov (United States)

    Nunes, T. V.; Miranda, A. I.; Duarte, S.; Lima, M. J.

    Aveiro is a flat small city in the centre of Portugal, close to the Atlantic coast. In the last two decades an intensive development of demographic, traffic and industry growth in the region was observed which was reflected on the air quality degrada- tion. In order to evaluate the urban air quality in Aveiro, a field-monitoring network by passive sampling with high space resolution was implemented. Twenty-four field places were distributed in a area of 3x3 Km2 and ozone and NO2 concentrations were measured. The site distribution density was higher in the centre, 250x250 m2 than in periphery where a 500x500 m2 grid was used. The selection of field places took into consideration the choice criteria recommendation by United Kingdom environmental authorities, and three tubes and a blank tube for each pollutant were used at each site. The sampling system was mounted at 3m from the ground usually profiting the street lampposts. Concerning NO2 acrylic tubes were used with 85 mm of length and an in- ternal diameter of 12mm, where in one of the extremities three steel grids impregnated with a solution of TEA were placed and fixed with a polyethylene end cup (Heal et al., 1999); PFA Teflon tube with 53 mm of length and 9 mm of internal diameter and three impregnated glass filters impregnated with DPE solution fixed by a teflon end cup was used for ozone sampling (Monn and Hargartner, 1990). The passive sampling method for ozone and nitrogen dioxide was compared with continuous measurements, but the amount of measurements wasnSt enough for an accurate calibration and validation of the method. Although this constraint the field observations (June to August 2001) for these two pollutants assign interesting information about the air quality in the urban area. A krigger method of interpolation (Surfer- Golden Software-2000) was applied to field data to obtain isolines distribution of NO2 and ozone concentration for the studied area. Even the used passive sampling method has many

  4. Software factory techniques applied to process control at CERN

    CERN Document Server

    Dutour, Mathias D

    2008-01-01

    The CERN Large Hadron Collider (LHC) requires constant monitoring and control of quantities of parameters to guarantee operational conditions. For this purpose, a methodology called UNICOS (UNIfied Industrial COntrols Systems) has been implemented to standardize the design of process control applications. To further accelerate the development of these applications, we migrated our existing UNICOS tooling suite toward a software factory in charge of assembling project, domain and technical information seamlessly into deployable PLC (Programmable logic Controller) - SCADA (Supervisory Control And Data Acquisition) systems. This software factory delivers consistently high quality by reducing human error and repetitive tasks, and adapts to user specifications in a cost-efficient way. Hence, this production tool is designed to encapsulate and hide the PLC and SCADA target platforms, enabling the experts to focus on the business model rather than specific syntaxes and grammars. Based on industry standard software, ...

  5. Software factory techniques applied to Process Control at CERN

    CERN Multimedia

    Dutour, MD

    2007-01-01

    The CERN Large Hadron Collider (LHC) requires constant monitoring and control of quantities of parameters to guarantee operational conditions. For this purpose, a methodology called UNICOS (UNIfied Industrial COntrols Systems) has been implemented to standardize the design of process control applications. To further accelerate the development of these applications, we migrated our existing UNICOS tooling suite toward a software factory in charge of assembling project, domain and technical information seamlessly into deployable PLC (Programmable logic Controller) – SCADA (Supervisory Control And Data Acquisition) systems. This software factory delivers consistently high quality by reducing human error and repetitive tasks, and adapts to user specifications in a cost-efficient way. Hence, this production tool is designed to encapsulate and hide the PLC and SCADA target platforms, enabling the experts to focus on the business model rather than specific syntaxes and grammars. Based on industry standard software...

  6. Effect of gamma radiation on honey quality control

    Energy Technology Data Exchange (ETDEWEB)

    Bera, A. [Radiation Technology Center, IPEN-CNEN/SP, A. Lineu Prestes, 2242, 05508-000 Sao Paulo (Brazil)], E-mail: berale@usp.br; Almeida-Muradian, L.B. [Av. Prof. Lineu Prestes, 580-Cidade Universitaria, Sao Paulo (Brazil); Sabato, S.F. [Radiation Technology Center, IPEN-CNEN/SP, A. Lineu Prestes, 2242, 05508-000 Sao Paulo (Brazil)], E-mail: sfsabato@ipen.br

    2009-07-15

    Honey is one of the most complex substances produced by bees, mainly from the nectar of flowers. Gamma radiation is a technique that can be used to decrease the number of microbiological problems associated with food and increase the shelf life of certain products. The objective of this study was to verify the effect of gamma radiation with source of cobalto-60 (10 kGy) on some parameters used in honey quality control. Seven samples of pure honey were obtained from local markets in Sao Paulo, Brazil, in 2007. The methods used are in accordance with Brazilian Regulations. The physicochemical parameters analyzed were: moisture, HMF, free acidity, pH, sugars and ash. The results showed that gamma radiation, in the dose mentioned above, did not cause significant physicochemical alterations.

  7. Effect of gamma radiation on honey quality control

    Science.gov (United States)

    Bera, A.; Almeida-Muradian, L. B.; Sabato, S. F.

    2009-07-01

    Honey is one of the most complex substances produced by bees, mainly from the nectar of flowers. Gamma radiation is a technique that can be used to decrease the number of microbiological problems associated with food and increase the shelf life of certain products. The objective of this study was to verify the effect of gamma radiation with source of cobalto-60 (10 kGy) on some parameters used in honey quality control. Seven samples of pure honey were obtained from local markets in Sao Paulo, Brazil, in 2007. The methods used are in accordance with Brazilian Regulations. The physicochemical parameters analyzed were: moisture, HMF, free acidity, pH, sugars and ash. The results showed that gamma radiation, in the dose mentioned above, did not cause significant physicochemical alterations.

  8. Control Techniques in Heating, Ventilating and Air Conditioning Systems

    Directory of Open Access Journals (Sweden)

    H. Mirinejad

    2008-01-01

    Full Text Available Problem statement: Heating, Ventilating and Air Conditioning (HVAC systems are among the main installations in residential, commercial and industrial buildings. The purpose of the HVAC systems is normally to provide a comfortable environment in terms of temperature, humidity and other environmental parameters for the occupants as well as to save energy. Achieving these objectives requires a suitable control system design. Approach: In this overview, thermal comfort level and ISO comfort field is introduced, followed by a review and comparison of the main existing control techniques used in HVAC systems to date. Results: The present overview shows that intelligent controllers which are based on the human sensation of thermal comfort have a better performance in providing thermal comfort as well as energy saving than the traditional controllers and those based on a model of the HVAC system. Conclusion: Such an overview provides an insight into current control methods in HVAC systems and can help scholars and HVAC learners to have the comprehensive information about a variety of control techniques in the field of HVAC and therefore to better design a proper controller for their work

  9. Low-Cost Quality Control and Nondestructive Evaluation Technologies for General Aviation Structures

    Science.gov (United States)

    Cramer, K. Elliott; Gavinsky, Bob; Semanskee, Grant

    1998-01-01

    NASA's Advanced General Aviation Transport Experiments (AGATE) Program has as a goal to reduce the overall cost of producing private aviation aircraft while maintaining the safety of these aircraft. In order to successfully meet this goal, it is necessary to develop nondestructive inspection techniques which will facilitate the production of the materials used in these aircraft and assure the quality necessary to maintain airworthiness. This paper will discuss a particular class of general aviation materials and several nondestructive inspection techniques that have proven effective for making these inspections. Additionally, this paper will discuss the investigation and application of other commercially available quality control techniques applicable to these structures.

  10. Employee quality, monitoring environment and internal control

    National Research Council Canada - National Science Library

    Chunli Liu Bin Lin Wei Shu

    2017-01-01

    ... quality.We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal...

  11. Seed layer technique for high quality epitaxial manganite films

    Science.gov (United States)

    Graziosi, P.; Gambardella, A.; Calbucci, M.; O’Shea, K.; MacLaren, D. A.; Bergenti, I.; Homonnay, N.; Schmidt, G.; Pullini, D.; Busquets-Mataix, D.; Dediu, V.

    2016-01-01

    We introduce an innovative approach to the simultaneous control of growth mode and magnetotransport properties of manganite thin films, based on an easy-to-implement film/substrate interface engineering. The deposition of a manganite seed layer and the optimization of the substrate temperature allows a persistent bi-dimensional epitaxy and robust ferromagnetic properties at the same time. Structural measurements confirm that in such interface-engineered films, the optimal properties are related to improved epitaxy. A new growth scenario is envisaged, compatible with a shift from heteroepitaxy towards pseudo-homoepitaxy. Relevant growth parameters such as formation energy, roughening temperature, strain profile and chemical states are derived. PMID:27648371

  12. Seed layer technique for high quality epitaxial manganite films

    Directory of Open Access Journals (Sweden)

    P. Graziosi

    2016-08-01

    Full Text Available We introduce an innovative approach to the simultaneous control of growth mode and magnetotransport properties of manganite thin films, based on an easy-to-implement film/substrate interface engineering. The deposition of a manganite seed layer and the optimization of the substrate temperature allows a persistent bi-dimensional epitaxy and robust ferromagnetic properties at the same time. Structural measurements confirm that in such interface-engineered films, the optimal properties are related to improved epitaxy. A new growth scenario is envisaged, compatible with a shift from heteroepitaxy towards pseudo-homoepitaxy. Relevant growth parameters such as formation energy, roughening temperature, strain profile and chemical states are derived.

  13. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  14. 10 CFR 26.167 - Quality assurance and quality control.

    Science.gov (United States)

    2010-01-01

    ... acceptable values are obtained for the known calibrators, those values will be used to calculate sample data... performing specific gravity tests: (i) The refractometer must report and display the specific gravity to four... initial and confirmatory specific gravity tests must have a calibrator or control at 1.0000; and (iii) The...

  15. H(sub infinity) techniques for spacecraft control

    Science.gov (United States)

    Frapard, B.; Leballois, S.; Champetier, C.

    1993-09-01

    The high performance Attitude and Orbit Control Systems (AOCS) and high accuracy Instrument Pointing Systems design require more and more control bandwidth: dynamic couplings can be no more neglected and control laws tend to be highly sensitive to the unmodeled dynamics. Multivariable systems analysis and optimal control synthesis tools, with robustness bounds/robustness constraints with respect to the unmodeled dynamics, are a major area of research for space applications. Among others, the large field of techniques provided by H(sub infinity) theory appears to be very promising. Two typical applications are presented in this paper, one concerning high accuracy pointing for observation satellites, with a particular interest in the SPOT Mark II platform, the other addressing the Drag Free Control problem for missions such as Aristoteles, STEP and Gravity Probe B.

  16. Managing Air Quality - Multi-Pollutant Planning and Control

    Science.gov (United States)

    Describes how planning controls for multiple pollutants at the same time can save money and time and achieve significant benefits, and how control strategies can address both climate change and air quality.

  17. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  18. Teaching Quality Control with Chocolate Chip Cookies

    Science.gov (United States)

    Baker, Ardith

    2014-01-01

    Chocolate chip cookies are used to illustrate the importance and effectiveness of control charts in Statistical Process Control. By counting the number of chocolate chips, creating the spreadsheet, calculating the control limits and graphing the control charts, the student becomes actively engaged in the learning process. In addition, examining…

  19. Evaluation of controls for the assurance of quality data in a radiochemistry laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Morton, J.S. [Radiological and Environmental Sciences Lab., Idaho Falls, ID (United States)

    1993-12-31

    The paper describes the controls implemented by the U.S. Department of Energy (DOE) at the Radiological and Environmental Sciences Laboratory (RESL) to secure data quality. A description of the analytical instrumentation and methodology employed by RESL is provided. The results of the intercomparison program with the National Institute of Standards and Technology (NIST) are provided to demonstrate traceability to a primary source. A description of the methods and techniques used to ensure quality control on a daily basis is given. The techniques used to evaluate the sources of uncertainty are reviewed and specific examples cited. The intercomparison programs operated by RESL are discussed.

  20. Developing risk-based quality control plans: an overview of CLSI EP23-A.

    Science.gov (United States)

    Person, Nils B

    2013-03-01

    What constitutes quality control (QC) in the clinical laboratory has expanded from being focused on the testing of QC samples to managing the risks of reporting incorrect patient results. To effectively implement this expanded vision of QC, the techniques of risk management are important tools. In 2011, the Clinical and Laboratory Standards Institute published EP23-A, Laboratory Quality Control Based on Risk Management, providing an introduction to risk management techniques and guidance on developing a risk-based QC plan. This article outlines the steps in developing and using a risk based QC plan based on the EP23 model.

  1. DTIPrep: Quality Control of Diffusion-Weighted Images

    Directory of Open Access Journals (Sweden)

    Ipek eOguz

    2014-01-01

    Full Text Available In the last decade, diffusion MRI (dMRI studies of the human and animal brain have been used to investigate a multitude of pathologies and drug-related effects in neuroscience research. Study after study identifies white matter (WM degeneration as a crucial biomarker for all these diseases. The tool of choice for studying WM is dMRI. However, dMRI has inherently low signal-to-noise ratio and its acquisition requires a relatively long scan time; in fact, the high loads required occasionally stress scanner hardware past the point of physical failure. As a result, many types of artifacts implicate the quality of diffusion imagery. Using these complex scans containing artifacts without quality control (QC can result in considerable error and bias in the subsequent analysis, negatively affecting the results of research studies using them. However, dMRI QC remains an under-recognized issue in the dMRI community as there are no user-friendly tools commonly available to comprehensively address the issue of dMRI QC. As a result, current dMRI studies often perform a poor job at dMRI QC.Thorough QC of diffusion MRI will reduce measurement noise and improve reproducibility, and sensitivity in neuroimaging studies; this will allow researchers to more fully exploit the power of the dMRI technique and will ultimately advance neuroscience. Therefore, in this manuscript, we present our open-source software, DTIPrep, as a unified, user friendly platform for thorough quality control of dMRI data. These include artifacts caused by eddy-currents, head motion, bed vibration and pulsation, venetian blind artifacts, as well as slice-wise and gradient-wise intensity inconsistencies. This paper summarizes a basic set of features of DTIPrep described earlier and focuses on newly added capabilities related to directional artifacts and bias analysis.

  2. [On-site quality control of acupuncture randomized controlled trial: design of content and checklist of quality control based on PICOST].

    Science.gov (United States)

    Li, Hong-Jiao; He, Li-Yun; Liu, Zhi-Shun; Sun, Ya-Nan; Yan, Shi-Yan; Liu, Jia; Zhao, Ye; Liu, Bao-Yan

    2014-02-01

    To effectively guarantee quality of randomized controlld trial (RCT) of acupuncture and develop reasonable content and checklist of on-site quality control, influencing factors on quality of acupuncture RCT are analyzed and scientificity of quality control content and feasibility of on-site manipulation are put into overall consideration. Based on content and checklist of on-site quality control in National 11th Five-Year Plan Project Optimization of Comprehensive Treatment Plan for TCM in Prevention and Treatment of Serious Disease and Clinical Assessment on Generic Technology and Quality Control Research, it is proposed that on-site quality control of acupuncture RCT should be conducted with PICOST (patient, intervention, comparison, out come, site and time) as core, especially on quality control of interveners' skills and outcome assessment of blinding, and checklist of on-site quality control is developed to provide references for undertaking groups of the project.

  3. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, Simone; Lizana, Ludvig; Otzen, Daniel

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency t...

  4. 7 CFR 58.733 - Quality control tests.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Quality control tests. 58.733 Section 58.733... Procedures § 58.733 Quality control tests. (a) Chemical analyses. The following chemical analyses shall be... pasteurization by means of the phosphatase test, as well as any other tests necessary to assure good...

  5. 75 FR 41874 - Quality Control for Rental Assistance Subsidy Determinations

    Science.gov (United States)

    2010-07-19

    ... URBAN DEVELOPMENT Quality Control for Rental Assistance Subsidy Determinations AGENCY: Office of the.... This notice also lists the following information: Title of Proposal: Quality Control for Rental... agency's estimate of the burden of the proposed collection of information; (3) Enhance the...

  6. Artificial Intelligence Approach to Support Statistical Quality Control Teaching

    Science.gov (United States)

    Reis, Marcelo Menezes; Paladini, Edson Pacheco; Khator, Suresh; Sommer, Willy Arno

    2006-01-01

    Statistical quality control--SQC (consisting of Statistical Process Control, Process Capability Studies, Acceptance Sampling and Design of Experiments) is a very important tool to obtain, maintain and improve the Quality level of goods and services produced by an organization. Despite its importance, and the fact that it is taught in technical and…

  7. Safety of timber: An analysis of quality control options

    NARCIS (Netherlands)

    Kovryga, A.; Stapel, P.; Van de Kuilen, J.W.G.

    2014-01-01

    The quality assurance of timber properties is important for the safety of timber structures. In the current study, the quality control options of timber are analysed under the prism of the different growth regions. Therefore, these options - machine and output control - are simulated in accordance w

  8. Quality control of geological voxel models using experts' gaze

    NARCIS (Netherlands)

    Maanen, van Peter-Paul; Busschers, Freek S.; Brouwer, Anne-Marie; Meulendijk, van der Michiel J.; Erp, van Jan B.F.

    2015-01-01

    Due to an expected increase in geological voxel model data-flow and user demands, the development of improved quality control for such models is crucial. This study explores the potential of a new type of quality control that improves the detection of errors by just using gaze behavior of 12 geologi

  9. Air quality management in the WHO European Region--results of a quality assurance and control programme on air quality monitoring (1994-2004).

    Science.gov (United States)

    Mücke, Hans-Guido

    2008-07-01

    Since the last decade the WHO Collaborating Centre for Air Quality Management and Air Pollution Control, Berlin, Germany, operates a quality assurance and control (QA/QC) programme on air quality monitoring in the WHO European Region. As main activity Intercomparison workshops have been established for air monitoring network laboratories on a regular basis to harmonise air quality measurements, analysis and calibration techniques. 36 air hygiene laboratories of public health and environmental institutions of 24 countries participated in twelve Intercomparisons between 1994 and 2004. The majority was carried out for NO, NO(2), SO(2) and O(3). The results were predominantly satisfactory for automatic methods. The results of manual methods were mainly in a good, and for several concentration levels partly very good accordance with the data obtained by the monitors.

  10. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  11. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  12. Quality control and assurance in anesthesia: A necessity of the modern times.

    Science.gov (United States)

    Bajwa, Sukhminder Jit Singh; Jindal, Ravi

    2014-01-01

    The advent of newer developments in anesthesia techniques and current clinical scenario has necessitated assurance of quality anesthesia services delivery. Numerous factors including availability of newer drugs, availability of newer advanced monitoring gadgets, increased awareness among the patient population, implementation of newer medico-legal laws and professional competitiveness has mandated a quality control and assurance in anesthesia. These domains of quality control are adapted from public health and are being incorporated into daily anesthesia practice in a gradual and phased manner. Quality control and assurance can be assessed and measured with certain quality indicators, which are also helpful in determining the perioperative outcome in anesthesia and surgical practice. Patient's perception about various anesthetic procedures, drug effects and recovery state are the prime underlying basis for assessing the quality assurance and control. At the same time, a positive impact of feedback mechanism cannot be under-emphasized while aiming for improvement in delivery of quality anesthesia services. The current review is aimed at highlighting the important aspects associated with quality assurance and quality control in anesthesia practice.

  13. Quality control and assurance in anesthesia: A necessity of the modern times

    Science.gov (United States)

    Bajwa, Sukhminder Jit Singh; Jindal, Ravi

    2014-01-01

    The advent of newer developments in anesthesia techniques and current clinical scenario has necessitated assurance of quality anesthesia services delivery. Numerous factors including availability of newer drugs, availability of newer advanced monitoring gadgets, increased awareness among the patient population, implementation of newer medico-legal laws and professional competitiveness has mandated a quality control and assurance in anesthesia. These domains of quality control are adapted from public health and are being incorporated into daily anesthesia practice in a gradual and phased manner. Quality control and assurance can be assessed and measured with certain quality indicators, which are also helpful in determining the perioperative outcome in anesthesia and surgical practice. Patient's perception about various anesthetic procedures, drug effects and recovery state are the prime underlying basis for assessing the quality assurance and control. At the same time, a positive impact of feedback mechanism cannot be under-emphasized while aiming for improvement in delivery of quality anesthesia services. The current review is aimed at highlighting the important aspects associated with quality assurance and quality control in anesthesia practice. PMID:25886215

  14. Friction estimation technique for Galileo scan platform control

    Science.gov (United States)

    Chodas, J. L.

    1982-01-01

    A friction estimation technique has been developed for the scan platform control of the Galileo spacecraft. The purpose of the estimation is to reduce the impact of friction in the scan platform actuator on the pointing performance of the scan platform so that tight pointing requirements can be met. The estimator operates by comparing the actual behavior of the platform with the expected behavior and attributing the difference to the presence of friction. The estimator is coupled with a proportional-integral-derivative controller to generate a control torque for the scan platform actuator. Since the algorithm will be implemented on an onboard digital computer, a stability analysis of the estimator-controller in discrete time is presented. The performance of the design is demonstrated by a sample slew test case.

  15. New approaches in intelligent control techniques, methodologies and applications

    CERN Document Server

    Kountchev, Roumen

    2016-01-01

    This volume introduces new approaches in intelligent control area from both the viewpoints of theory and application. It consists of eleven contributions by prominent authors from all over the world and an introductory chapter. This volume is strongly connected to another volume entitled "New Approaches in Intelligent Image Analysis" (Eds. Roumen Kountchev and Kazumi Nakamatsu). The chapters of this volume are self-contained and include summary, conclusion and future works. Some of the chapters introduce specific case studies of various intelligent control systems and others focus on intelligent theory based control techniques with applications. A remarkable specificity of this volume is that three chapters are dealing with intelligent control based on paraconsistent logics.

  16. Adaptive Quality of Transmission Control in Elastic Optical Network

    Science.gov (United States)

    Cai, Xinran

    Optical fiber communication is becoming increasingly important due to the burgeoning demand in the internet capacity. However, traditional wavelength division multiplexing (WDM) technique fails to address such demand because of its inefficient spectral utilization. As a result, elastic optical networking (EON) has been under extensive investigation recently. Such network allows sub-wavelength and super-wavelength channel accommodation, and mitigates the stranded bandwidth problem in the WDM network. In addition, elastic optical network is also able to dynamically allocate the spectral resources of the network based on channel conditions and impairments, and adaptively control the quality of transmission of a channel. This application requires two aspects to be investigated: an efficient optical performance monitoring scheme and networking control and management algorithms to reconfigure the network in a dynamic fashion. This thesis focuses on the two aspects discussed above about adaptive QoT control. We demonstrated a supervisory channel method for optical signal to noise ratio (OSNR) and chromatic dispersion (CD) monitoring. In addition, our proof-of-principle testbed experiments show successful impairment aware reconfiguration of the network with modulation format switching (MFS) only and MFS combined with lightpath rerouting (LR) for hundred-GHz QPSK superchannels undergoing time-varying OSNR impairment.

  17. Key techniques of automatic gauge control and profile control for aluminium strip and foil

    Institute of Scientific and Technical Information of China (English)

    LI Mou-wei; LIU Hong-fei; WANG Xiang-li; TONG Chao-nan; YIN Feng-fu; BIAN Xin-xiao; ZHANG Lei

    2006-01-01

    Such characteristics of aluminium strip and foil as soft and thin gauge make tension control one of the key techniques for automation gauge control(AGC). To avoid the disadvantage of traditional mathematical control method which is unfitful for nonlinear hysteresis, the technique for tension AGC fuzzy control was developed and thickness deviation more than 3% of product thickness was achieved consequently in 1 350 mm cold rolling mill of aluminium strip and foil. Additionally, because the gauge of aluminium strip and foil is thin, stage-cooling roll method becomes a key technique for profile control. So stage-cooling roll intelligent control method is developed and pre-coated aluminum foil with good profile less than 10 I (the relative differences in elongation of 0.01% ) is produced using the profile control system in 1 400 mm cold rolling mill of aluminium strip and foil.

  18. Videoregistration of surgery should be used as a quality control.

    Science.gov (United States)

    Koninckx, Philippe R

    2008-01-01

    Quality control of medical treatment is strictly organized and supervised. Efficacy and safety have to be proven in large randomized controlled trials, which need ethical review board approval. Content and quality of marketed drugs is controlled by industry and government. After market introduction, postmarketing surveillance is organized. This quality control is necessary to obtain reliable and predictable results and to detect even rare adverse events. Quality control of surgical treatments is close to nonexistent for individual surgical procedures and, therefore, rare adverse events cannot be detected by the sheer number of interventions analyzed. An ethical review board is rarely consulted before a new procedure is attempted or introduced. Although the outcome of surgery is surgeon and environment dependent, the only estimation of quality is results and complication rates. These, however, reflect publications by dedicated groups or data from surveys that do not necessarily reflect reality accurately. Complications are known to be under-reported whereas surveys reflect mean quality only. For most complication rates, it remains unknown which were preventable mistakes and which were unavoidable, random accidents. This huge discrepancy in quality control of medical and surgical therapies can be understood by specifics of each type of therapy. Strict quality control in surgery is, moreover, difficult to organize given that the outcome varies with the surgeon and surgical environment. Systematic videotaping of entire interventions has the potential of providing a quality control of surgery. This, moreover, has become technically feasible at low cost. In conclusion, we need to reflect and organize quality control in surgery. Systematic videotaping of entire procedures seems to be an inexpensive and easy way to organize this control.

  19. Acceptance, commissioning and quality control in radiosurgery; Aceite, comissionamento e controle de qualidade em radiocirurgia

    Energy Technology Data Exchange (ETDEWEB)

    Toreti, Dalila Luzia

    2009-07-01

    Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multi leaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab micro multi leaf collimator installed in the Hospital das Clinicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance.

  20. Greenhouse climate control affects postharvest tomato quality

    NARCIS (Netherlands)

    Farneti, B.; Schouten, R.E.; Qian, T.; Dieleman, J.A.; Tijskens, L.M.M.; Woltering, E.J.

    2013-01-01

    In this study, important quality properties such as firmness, sugar and acid levels were measured and analysed in tomatoes harvested from three greenhouses during a five month period and stored at 16 degrees C for over 20 days. Tomatoes were harvested from three identical, neighbouring, greenhouses

  1. Automated X-ray quality control of catalytic converters

    Science.gov (United States)

    Shashishekhar, N.; Veselitza, D.

    2017-02-01

    Catalytic converters are devices attached to the exhaust system of automobile or other engines to eliminate or substantially reduce polluting emissions. They consist of coated substrates enclosed in a stainless steel housing. The substrate is typically made of ceramic honeycombs; however stainless steel foil honeycombs are also used. The coating is usually a slurry of alumina, silica, rare earth oxides and platinum group metals. The slurry also known as the wash coat is applied to the substrate in two doses, one on each end of the substrate; in some cases multiple layers of coating are applied. X-ray imaging is used to inspect the applied coating depth on a substrate to confirm compliance with quality requirements. Automated image analysis techniques are employed to measure the coating depth from the X-ray image. Coating depth is assessed by analysis of attenuation line profiles in the image. Edge detection algorithms with noise reduction and outlier rejection are used to calculate the coating depth at a specified point along an attenuation line profile. Quality control of the product is accomplished using several attenuation line profile regions for coating depth measurements, with individual pass or fail criteria specified for each region.

  2. Site-controlled quantum dots fabricated using an atomic-force microscope assisted technique

    Directory of Open Access Journals (Sweden)

    Sakuma Y

    2006-01-01

    Full Text Available AbstractAn atomic-force microscope assisted technique is developed to control the position and size of self-assembled semiconductor quantum dots (QDs. Presently, the site precision is as good as ± 1.5 nm and the size fluctuation is within ± 5% with the minimum controllable lateral diameter of 20 nm. With the ability of producing tightly packed and differently sized QDs, sophisticated QD arrays can be controllably fabricated for the application in quantum computing. The optical quality of such site-controlled QDs is found comparable to some conventionally self-assembled semiconductor QDs. The single dot photoluminescence of site-controlled InAs/InP QDs is studied in detail, presenting the prospect to utilize them in quantum communication as precisely controlled single photon emitters working at telecommunication bands.

  3. Antimisting Kerosene: Base Fuel Effects; Blending and Quality Control Techniques.

    Science.gov (United States)

    1984-01-01

    applications of static mixer in the chemical, refining, poly- mer, food and other major processing industries. 3.3.2 Development of the Blending Process Since...filter. Hold stopper steady until removal. Excess motion may induce gelation in the filter. 5. Tilt apparatus to diagonal and pour the reference jet A

  4. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  5. Methodical Grounds of Managing the Product Quality Control

    Directory of Open Access Journals (Sweden)

    Shapoval Olena A.

    2014-01-01

    Full Text Available The article analyses the modern state of products quality control management. It justifies a necessity of organisation of the quality control system under conditions of uninterrupted flow line production. It reveals problems connected with a low level of the products quality control management. It forms a set of factors of internal and external environments, which should be taken into account in the process of selection of a type of managerial actions by the products quality control. It considers specific features of identification of the most important factors at an enterprise on the basis of use of the matrix of strategic SWOT analysis. It offers a procedure of identification of a general assessment of factors of influence. It analyses a mechanism of use of main conceptual models, which reflect the system nature of quality management in an organisation – quality pyramids and quality loops. It proves a necessity of application of a principally new scheme of relations between the customer and enterprise, which envisages that requirements of the quality management system focus not on control and screening of semi-finished products, but on creation of conditions that exclude rejects. It considers the role of ISO 9000 in the system of quality management, which recommend the customers to make a preliminary assessment of activity of the producing enterprise.

  6. Water quality analysis of the Rapur area, Andhra Pradesh, South India using multivariate techniques

    Science.gov (United States)

    Nagaraju, A.; Sreedhar, Y.; Thejaswi, A.; Sayadi, Mohammad Hossein

    2016-11-01

    The groundwater samples from Rapur area were collected from different sites to evaluate the major ion chemistry. The large number of data can lead to difficulties in the integration, interpretation, and representation of the results. Two multivariate statistical methods, hierarchical cluster analysis (HCA) and factor analysis (FA), were applied to evaluate their usefulness to classify and identify geochemical processes controlling groundwater geochemistry. Four statistically significant clusters were obtained from 30 sampling stations. This has resulted two important clusters viz., cluster 1 (pH, Si, CO3, Mg, SO4, Ca, K, HCO3, alkalinity, Na, Na + K, Cl, and hardness) and cluster 2 (EC and TDS) which are released to the study area from different sources. The application of different multivariate statistical techniques, such as principal component analysis (PCA), assists in the interpretation of complex data matrices for a better understanding of water quality of a study area. From PCA, it is clear that the first factor (factor 1), accounted for 36.2% of the total variance, was high positive loading in EC, Mg, Cl, TDS, and hardness. Based on the PCA scores, four significant cluster groups of sampling locations were detected on the basis of similarity of their water quality.

  7. Simple Augmented Current Controller with OHC Technique for grid current compensation in the Distribution System

    Directory of Open Access Journals (Sweden)

    S. Rajalingam

    2014-05-01

    Full Text Available This paper presents a novel control technique on four leg inverter with which the distribution grid is interconnected with the domestic houses. Most of the houses in the distribution side possess inverter for the usage of Electricity. With the advancement in Solar & wind, it will become easy to see houses, often with solar & a small Wind power system. The excess power generated can be exchanged with the Electricity Board for providing uninterruptible power supply. During this exchange there may be a deterioration in the quality of power, most often the grid current gets affected with a large harmonic distortion, and also there exists unbalanced grid currents. Thus, it is necessary to provide uninterruptible power supply with good quality of power. In spite of several controllers, the proposed augmented controller has its own reliability & quick response with Overall Harmonic Compensation (OHC technique which relies on DSP based filter. This Augmented based control technique with OHC is demonstrated extensively with MATLAB/Simulink simulation.

  8. Implementation of closed loop control technique for improving the performances of PWM inverter-A review

    Directory of Open Access Journals (Sweden)

    V. M. Deshmukh

    2014-10-01

    Full Text Available this review paper presents closed loop control techniques for controlling the inverter working under different load or KVA ratings. The control strategy of the inverter must guarantee its output waveforms to be sinusoidal with fundamental harmonic. For this purpose, close loop current control strategies such as H∞ repetitive controller, dual closed-loop feedback control, Adaptive Voltage Control, SRFPI controller, Optimal Neural Controller, etc. have been used to meet the power quality requirements imposed by IEEE Interconnection Standards. Based on present scenario regarding energy crises, immediate action is the use of different renewable energy sources (RESs . Out of RESs, solar is gaining more attention. It is very important to design and developed a system which should be efficient enough to utilize the extracted energy for different types of load and feeding of energy into utility grid. Since experimentation and comparison of such inverter models on hardware being relatively expensive, the latest computing tool like MATLAB are considered to be a better alternative to simulate the outcomes of such expensive systems. The proposed closed loop control technique for the inverter working under linear and nonlinear system will be implemented in MATLAB/SIMULINK working platform and results will be analyzed to check its benefits.

  9. New regulatory framework for wastewater quality control in Mexico.

    Science.gov (United States)

    Saade Hazin, L

    2000-01-01

    This paper analyses the new regulatory framework for wastewater quality control developed in Mexico. It provides a description of the Mexican government strategies for water pollution control. The discussion focuses on the policy instruments used, their evolution and the main difficulties encountered in their implementation. The new regulatory framework is discussed highlighting some of the economic implications of the reforms. The paper concludes that proper institutional development and monitoring are essential factors for the success of any policy instrument for wastewater quality control.

  10. Quality control aspects of herbs and botanicals in developing countries: Coleus forskohlii Briq a case study

    Directory of Open Access Journals (Sweden)

    Ennus Tajuddin Tamboli

    2015-01-01

    Full Text Available Objective: Current trend of commercialization of herbal medicines draw a huge need of maintaining their quality. The declaration of quality, safety and efficacy of medicinal plants as well as poly-herbal formulations has become an important issue. Hence, qualitative and quantitative analysis of herbal drugs and formulations viz., fingerprint profiles and quantification of the various markers become key factors of quality control. Materials and Methods: Present investigation is a detailed report for quality control of well-known herb Coleus forskohlii Briq, which includes physicochemical parameter determination, safety evaluation, microscropical evaluation, and chromatographic fingerprinting as well. Results: Physico-chemical characters were evaluated according to Indian Pharmacopoeia, further microscopic evaluation of transverse section of Coleus reveals that periderm, secondary phloem, and wide secondary xylem cylinder, which occupies major portion of the root fragmentary. Chromatographic fingerprint profiles of Coleus have been generated, and a marker based standardization strategy was adopted; using different analytical technique like high-performance thin layer chromatography, high-performance liquid chromatography and gas chromatography-mass spectroscopy to maintain quality and ensure safety as well as efficacy. Conclusion: These advancements in modern techniques of analysis can lead to effective quality control of Coleus as well as other herbs. Present report can act as pioneer for quality control of modern herbal medicine.

  11. Influence of inhaler technique on asthma and COPD control: a multicenter experience

    Science.gov (United States)

    Dudvarski Ilic, Aleksandra; Zugic, Vladimir; Zvezdin, Biljana; Kopitovic, Ivan; Cekerevac, Ivan; Cupurdija, Vojislav; Perhoc, Nela; Veljkovic, Vesna; Barac, Aleksandra

    2016-01-01

    Background The successful management of asthma and chronic obstructive pulmonary disease (COPD) mostly depends on adherence to inhalation drug therapy, the usage of which is commonly associated with many difficulties in real life. Improvement of patients’ adherence to inhalation technique could lead to a better outcome in the treatment of asthma and COPD. Objective The aim of this study was to assess the utility of inhalation technique in clinical and functional control of asthma and COPD during a 3-month follow-up. Methods A total of 312 patients with asthma or COPD who used dry powder Turbuhaler were enrolled in this observational study. During three visits (once a month), training in seven-step inhalation technique was given and it was practically demonstrated. Correctness of patients’ usage of inhaler was assessed in three visits by scoring each of the seven steps during administration of inhaler dose. Assessment of disease control was done at each visit and evaluated as: fully controlled, partially controlled, or uncontrolled. Patients’ subjective perception of the simplicity of inhalation technique, disease control, and quality of life were assessed by using specially designed questionnaires. Results Significant improvement in inhalation technique was achieved after the third visit compared to the first one, as measured by the seven-step inhaler usage score (5.94 and 6.82, respectively; P<0.001). Improvement of disease control significantly increased from visit 1 to visit 2 (53.9% and 74.5%, respectively; P<0.001) and from visit 2 to visit 3 (74.5% and 77%, respectively; P<0.001). Patients’ subjective assessment of symptoms and quality of life significantly improved from visit 1 to visit 3 (P<0.001). Conclusion Adherence to inhalation therapy is one of the key factors of successful respiratory disease treatment. Therefore, health care professionals should insist on educational programs aimed at improving patients’ inhalation technique with different

  12. Microstructure control techniques in primary hot working of titanium alloy bars:A review

    Institute of Scientific and Technical Information of China (English)

    Guo Lianggang; Fan Xiaoguang; Yu Gaofeng; Yang He

    2016-01-01

    How to control the microstructure of titanium alloy bars is important to fabricating high-performance aerial forgings. This paper gives a thorough survey of the manufacturing meth-ods and microstructure control techniques for titanium alloy bars. It summarizes the effects of pro-cessing parameters on the mechanisms and laws of microstructure evolution during b working and (a+b) working, including the kinetics and grains size of dynamic recrystallization (DRX) during b deformation and the kinetics and grains size of spheroidization during (a+b) deformation. The trends in microstructure control techniques are presented for fabricating titanium alloy bars with high efficiency, low cost, and high quality by means of b/(a+b) working, and the puzzles and chal-lenges in the future are also pointed out.

  13. Totally Carrying out Zero Defects Quality Control

    Institute of Scientific and Technical Information of China (English)

    ZhangQingwei; CASCPresident

    2004-01-01

    Editorial note: On March 22,1992 the launch of LM-2E launch vehicle with an Australian satellite was terminated. A piece of 0.15 milligram aluminum redundance led to the malfunction of the program distributor, which caused the emergency cutoff after 7 seconds of the ignition of the rocket. To bear in mind the painful lesson, China Aerospace Corporation set out March 22 to be “Space Quality Day” in 1994.

  14. L2-gain and passivity techniques in nonlinear control

    CERN Document Server

    van der Schaft, Arjan

    2017-01-01

    This standard text gives a unified treatment of passivity and L2-gain theory for nonlinear state space systems, preceded by a compact treatment of classical passivity and small-gain theorems for nonlinear input-output maps. The synthesis between passivity and L2-gain theory is provided by the theory of dissipative systems. Specifically, the small-gain and passivity theorems and their implications for nonlinear stability and stabilization are discussed from this standpoint. The connection between L2-gain and passivity via scattering is detailed. Feedback equivalence to a passive system and resulting stabilization strategies are discussed. The passivity concepts are enriched by a generalised Hamiltonian formalism, emphasising the close relations with physical modeling and control by interconnection, and leading to novel control methodologies going beyond passivity. The potential of L2-gain techniques in nonlinear control, including a theory of all-pass factorizations of nonlinear systems, and of parametrization...

  15. Application of altitude control techniques for low altitude earth satellites

    Science.gov (United States)

    Nickerson, K. G.; Herder, R. W.; Glass, A. B.; Cooley, J. L.

    1977-01-01

    The applications sensors of many low altitude earth satellites designed for recording surface or atmospheric data require near zero orbital eccentricities for maximum usefulness. Coverage patterns and altitude profiles require specified values of orbit semimajor axis. Certain initial combinations of semimajor axis, eccentricity, and argument of perigee can produce a so called 'frozen orbit' and minimum altitude variation which enhances sensor coverage. This paper develops information on frozen orbits and minimum altitude variation for all inclinations, generalizing previous results. In the altitude regions where most of these satellites function (between 200 and 1000 kilometers) strong atmospheric drag effects influence the evolution of the initial orbits. Active orbital maneuver control techniques to correct evolution of orbit parameters while minimizing the frequency of maneuvers are presented. The paper presents the application of theoretical techniques for control of near frozen orbits and expands upon the methods useful for simultaneously targeting several inplane orbital parameters. The applications of these techniques are illustrated by performance results from the Atmosphere Explorer (AE-3 and -5) missions and in preflight maneuver analysis and plans for the Seasat Oceanographic Satellite.

  16. Integrated controlling technique of ecological environment in Shendong Mining Area

    Institute of Scientific and Technical Information of China (English)

    ZHANG Dong-sheng; LIU Yu-de; WANG An; WANG Yi

    2007-01-01

    To enclose the interactive relation between the underground mining with suitable protection for surface ecological environments and surface prevention of ecological environments adapting to mining disturbing was researched and developed core of this technique. There are three aspects of controlling ecological environments, to dispose and renew before exploitation, to protect surface ecological environments in the exploitative process and to repair and build up after exploitation. Based on the moving law of overburden strata in shallow seam, the surface subsidence law and the growth law of vegetation in subsidence mine area, the integrated controlling technique has been developed synthetically by methods of theoretic analysis, laboratory simulation, numerical calculation,commercial test etc.. It includes the key techniques of aquifer-protective mining, filtering and purging of mine water through goaf, preventing and extinguishing fire in shallow seam,no-rock roadway layout and waste disposal in underground, frame-building ecological functional sphere before exploitation, frame-building the ecological cycle using system after mining and so on.

  17. Innovative Hyperspectral Imaging-Based Techniques for Quality Evaluation of Fruits and Vegetables: A Review

    Directory of Open Access Journals (Sweden)

    Yuzhen Lu

    2017-02-01

    Full Text Available New, non-destructive sensing techniques for fast and more effective quality assessment of fruits and vegetables are needed to meet the ever-increasing consumer demand for better, more consistent and safer food products. Over the past 15 years, hyperspectral imaging has emerged as a new generation of sensing technology for non-destructive food quality and safety evaluation, because it integrates the major features of imaging and spectroscopy, thus enabling the acquisition of both spectral and spatial information from an object simultaneously. This paper first provides a brief overview of hyperspectral imaging configurations and common sensing modes used for food quality and safety evaluation. The paper is, however, focused on the three innovative hyperspectral imaging-based techniques or sensing platforms, i.e., spectral scattering, integrated reflectance and transmittance, and spatially-resolved spectroscopy, which have been developed in our laboratory for property and quality evaluation of fruits, vegetables and other food products. The basic principle and instrumentation of each technique are described, followed by the mathematical methods for processing and extracting critical information from the acquired data. Applications of these techniques for property and quality evaluation of fruits and vegetables are then presented. Finally, concluding remarks are given on future research needs to move forward these hyperspectral imaging techniques.

  18. Quality Control and Assurance for Coagulation Tests

    Institute of Scientific and Technical Information of China (English)

    彭黎明

    2006-01-01

    @@ The coagulation laboratory aids the clinician in assessing not only the bleeding patient but also the thrombotic patient. The techniques of coagulation laboratory are used to evaluate not only the coagulation system but also the anti-coagulation system, fibrinolytic system,platelet and vascular endothelial function. Enzymes, inhibitors, plasma factors and co-factors, cellular release products, and cell receptors can be measured in coagulation laboratory.

  19. A New Mathematical Modeling Technique for Pull Production Control Systems

    Directory of Open Access Journals (Sweden)

    O. Srikanth

    2013-12-01

    Full Text Available The Kanban Control System widely used to control the release of parts of multistage manufacturing system operating under a pull production control system. Most of the work on Kanban Control System deals with multi-product manufacturing system. In this paper, we are proposing a regression modeling technique in a multistage manufacturing system is to be coordinates the release of parts into each stage of the system with the arrival of customer demands for final products. And also comparing two variants stages of the Kanban Control System model and combines with mathematical and Simulink model for the production coordination of parts in an assembly manufacturing systems. In both variants, the production of a new subassembly is authorized only when an assembly Kanban is available. Assembly kanbans become available when finished product is consumed. A simulation environment for the product line system has to generate with the proposed model and the mathematical model have to give implementation against the simulation model in the working platform of MATLAB. Both the simulation and model outputs have provided an in depth analysis of each of the resulting control system for offering model of a product line system.

  20. Reinforcement learning techniques for controlling resources in power networks

    Science.gov (United States)

    Kowli, Anupama Sunil

    As power grids transition towards increased reliance on renewable generation, energy storage and demand response resources, an effective control architecture is required to harness the full functionalities of these resources. There is a critical need for control techniques that recognize the unique characteristics of the different resources and exploit the flexibility afforded by them to provide ancillary services to the grid. The work presented in this dissertation addresses these needs. Specifically, new algorithms are proposed, which allow control synthesis in settings wherein the precise distribution of the uncertainty and its temporal statistics are not known. These algorithms are based on recent developments in Markov decision theory, approximate dynamic programming and reinforcement learning. They impose minimal assumptions on the system model and allow the control to be "learned" based on the actual dynamics of the system. Furthermore, they can accommodate complex constraints such as capacity and ramping limits on generation resources, state-of-charge constraints on storage resources, comfort-related limitations on demand response resources and power flow limits on transmission lines. Numerical studies demonstrating applications of these algorithms to practical control problems in power systems are discussed. Results demonstrate how the proposed control algorithms can be used to improve the performance and reduce the computational complexity of the economic dispatch mechanism in a power network. We argue that the proposed algorithms are eminently suitable to develop operational decision-making tools for large power grids with many resources and many sources of uncertainty.

  1. Synthesis and quality control of [{sup 18}F] fluorothymidine

    Energy Technology Data Exchange (ETDEWEB)

    Nascimento, Leonardo Tafas C.; Silva, Juliana B.; Silveira, Marina B.; Santos, Priscilla F.; Faria, Tiago, E-mail: ltcn@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2013-07-01

    The Positron Emission Tomography (PET) is a technique that allows early diagnosis of various diseases by detecting metabolic changes of cells, in addition to being a noninvasive technique. The most widely used radiopharmaceutical for PET imaging is [{sup 18}F] Fludesoxiglucose ({sup 18}FDG), which is a marker of glucose metabolism and has high sensitivity and specificity for diagnosis and staging of various cancers. However, some carcinomas do not have high glucose consumption, besides {sup 18}FDG possess high urinary excretion rate interfering with the detection of tumors in pelvis and high uptake in brain and in inflammation, reducing the contrast tumor / background. The radiotracer 3'-fluoro-L-3'-deoxythymidine ({sup 18}FLT) is an analogue of thymidine used as an alternative to {sup 18}FDG for detecting tumors with high proliferation rate. The aim of this work was to develop [{sup 18}F] Fluorothymidine synthesis and quality control at the Radiopharmaceuticals Research and Production Facility of CDTN/CNEN. The synthesis was adapted from that used to {sup 18}FDG, based on the methodologies described in related papers. Radiochemical purity and impurities levels were determined by HPLC, RTLC and GC techniques. Total synthesis time was 35 minutes and the radiochemical yield in the end of bombardment (EOB) was 7%, with a radiochemical purity of about 93%. Radionuclidic identity and purity, pH, residual solvents, radiochemical and chemical purity were evaluated according to analytical methods described on the literature and on the United States Pharmacopeia (USP 32). Residual levels of Stavudine, Thymine and Thymidine were found and are under toxicological investigation in order to establish a maximum amount allowed in the final product. (author)

  2. Combined Control Scheme for Monitoring Quality Characteristics

    Directory of Open Access Journals (Sweden)

    Adekeye K.S.

    2014-07-01

    Full Text Available In the literature, the Exponentially Weighted Moving Average (EWMA and Exponentially Weighted Moving Variance (EMWV control schemes have been used separately to monitor the process average and process variability respectively. Here the two are combined and applied on simulated process with different level of variation. The control limit interval (CLI and the average run length (ARL were evaluated for the combined chart. The combined chart performed better than the two independently. Furthermore, an algorithm was developed for the two control charts and implemented on visual basic VB6.0. The obtained results show that the combined EWMA and EWMV control chart is very sensitive in detecting shift in production process and every shift in the process mean is always preceded by shift in the process variability.

  3. Production Quality Control Of Microfluidic Chip Designs

    DEFF Research Database (Denmark)

    Calaon, Matteo; Hansen, Hans Nørgaard; Tosello, Guido

    2012-01-01

    -beam lithography. Subsequent nickel electroplating was employed to replicate the obtained geometries on the tool, which was used to mold on transparent polymer substrates the functional structures. To assess the critical factors affecting the replication quality throughout the different steps of the proposed...... process chain, test geometries were designed and produced on the side of the functional features. The so called “Finger Print” of the lithography and molding processes was qualitatively and quantitatively evaluated through scanning electron microscopy and atomic force microscopy respectively. The entire...

  4. Quality Control Analytical Methods: Method Validation.

    Science.gov (United States)

    Klang, Mark G; Williams, LaVonn A

    2016-01-01

    To properly determine the accuracy of a pharmaceutical product or compounded preparation, tests must be designed specifically for that evaluation. The procedures selected must be verified through a process referred to as method validation, an integral part of any good analytical practice. The results from a method validation procedure can be used to judge the quality, reliability, and consistency of analytical results. The purpose of this article is to deliver the message of the importance of validation of a pharmaceutical product or compounded preparation and to briefly discuss the results of a lack of such validation. Copyright© by International Journal of Pharmaceutical Compounding, Inc.

  5. Agricultural biological reference materials for analytical quality control

    Energy Technology Data Exchange (ETDEWEB)

    Ihnat, M.

    1986-01-01

    Cooperative work is under way at Agriculture Canada, US Department of Agriculture, and US National Bureau of Standards in an attempt to fill some of the gaps in the world repertoire of reference materials and to provide much needed control materials for laboratories' day to day operations. This undertaking involves the preparation and characterization of a number of agricultural and food materials for data quality control for inorganic constituents. Parameters considered in the development of these materials were material selection based on importance in commerce and analysis; techniques of preparation, processing, and packaging; physical and chemical characterization; homogeneity testing and quantitation (certification). A large number of agricultural/food products have been selected to represent a wide range of not only levels of sought-for constituents (elements) but also a wide range of matrix components such as protein, carbohydrate, dietary fiber, fat, and ash. Elements whose concentrations are being certified cover some two dozen major, minor, and trace elements of nutritional, toxicological, and environmental significance.

  6. IMPLEMENTATION OF SPACE VECTOR PULSE WIDTH MODULATION TECHNIQUE WITH GENETIC ALGORITHM TO OPTIMIZE UNIFIED POWER QUALITY CONDITIONER

    Directory of Open Access Journals (Sweden)

    M. Shankar

    2014-01-01

    Full Text Available This study proposes a novel control design of Unified Power Quality Conditioner (UPQC. This design is enabled by a control framework that employs Genetic Algorithm which determines optimum points and angle for filtering and Space Vector Pulse Width Modulation Technique (SVPWM to offer significant flexibility to optimize waveform. In addition the same framework integrates the major functions of the UPQC with ease to unify the treatments of several power quality problems including system harmonics in the supply voltage and load current, sags/swells in the supply voltage, variations in the load demands and poor power factor at the supply side. Simulation studies on a three phase power distribution system are used to verify the performance and implementation of this control design with the UPQC.

  7. Applicability of PTR-MS in the quality control of saffron

    NARCIS (Netherlands)

    Nenadis, Nikolaos; Heenan, Samuel; Tsimidou, Maria Z.; Ruth, Van Saskia

    2016-01-01

    The applicability of the emerging non-destructive technique, proton transfer reaction mass spectrometry (PTR-MS), was explored for the first time in the quality control of saffron. Monitoring of volatile organic compounds (VOCs) was achieved using a minute sample (35 mg). Fresh saffron was stored

  8. Applicability of PTR-MS in the quality control of saffron

    NARCIS (Netherlands)

    Nenadis, Nikolaos; Heenan, Samuel; Tsimidou, Maria Z.; Ruth, Van Saskia

    2016-01-01

    The applicability of the emerging non-destructive technique, proton transfer reaction mass spectrometry (PTR-MS), was explored for the first time in the quality control of saffron. Monitoring of volatile organic compounds (VOCs) was achieved using a minute sample (35 mg). Fresh saffron was stored

  9. HRCT: hop-by-hop rate control technique for congestion control in wireless sensor network

    Science.gov (United States)

    Chakravarthi, Rekha; Cidambaram, Gomathy

    2011-12-01

    In Wireless Sensor Networks, congestion occurs when the traffic rate is high. This happens when the an event is detected in a network. Congestion causes packet loss thus degrading the performance of the network. Hence it necessitates to develop an effective congestion control technique. This paper focuses on congestion due to concurrent transmission. We have proposed an efficient protocol to detect and control congestion in a MAC. The occurrence of congestion is detected by calculating a new metrics called congestion scale. When the congestion scale exceeds the threshold value it intimates, that, congestion has occurred. Congestion notification signal is send to all the nodes. On receiving the notification signal all nodes adjust their transmission rate to control congestion. We have implemented Hop-by-Hop Rate Control Technique(HRCT) to control congestion and to guarantee both high throughput and minimum delay. This technique is implemented successfully in NS-2 simulator. Finally, simulation results have demonstrated the effectiveness of our proposed algorithm.

  10. Web quality control for lectures: Supercourse and Amazon.com.

    Science.gov (United States)

    Linkov, Faina; LaPorte, Ronald; Lovalekar, Mita; Dodani, Sunita

    2005-12-01

    Peer review has been at the corner stone of quality control of the biomedical journals in the past 300 years. With the emergency of the Internet, new models of quality control and peer review are emerging. However, such models are poorly investigated. We would argue that the popular system of quality control used in Amazon.com offers a way to ensure continuous quality improvement in the area of research communications on the Internet. Such system is providing an interesting alternative to the traditional peer review approaches used in the biomedical journals and challenges the traditional paradigms of scientific publishing. This idea is being explored in the context of Supercourse, a library of 2,350 prevention lectures, shared for free by faculty members from over 150 countries. Supercourse is successfully utilizing quality control approaches that are similar to Amazon.com model. Clearly, the existing approaches and emerging alternatives for quality control in scientific communications needs to be assessed scientifically. Rapid explosion of internet technologies could be leveraged to produce better, more cost effective systems for quality control in the biomedical publications and across all sciences.

  11. Alar setback technique: a controlled method of nasal tip deprojection.

    Science.gov (United States)

    Foda, H M

    2001-11-01

    To describe an alar cartilage-modifying technique aimed at decreasing nasal tip projection in cases with overdeveloped alar cartilages and to compare it with other deprojection techniques used to correct such deformity. Selected case series. University and private practice settings in Alexandria, Egypt. Twenty patients presenting for rhinoplasty who had overprojected nasal tips primarily due to overdeveloped alar cartilages. All cases were primary cases except for one patient, who had undergone 2 previous rhinoplasties. An external rhinoplasty approach was used to set back the alar cartilages by shortening their medial and lateral crura. The choice of performing a high or low setback depended on the preexisting lobule-to-columella ratio. Following the setback, the alar cartilages were reconstructed in a fashion that increased the strength and stability of the tip complex. Subjective evaluation included clinical examination, analysis of preoperative and postoperative photographs, and patient satisfaction. Objective evaluation of nasal tip projection, using the Goode ratio and the nasofacial angle, was performed preoperatively and repeated at least 6 months postoperatively. A low setback was performed in 16 cases (80%) and a high setback in 4 (20%). The mean follow-up period was 18 months (range, 6-36 months). The technique effectively deprojected the nasal tip as evidenced by the considerable postoperative decrease in values of the Goode ratio and the nasofacial angle. No complications were encountered and no revision surgical procedures were required. The alar setback technique has many advantages; it results in precise predictable amounts of deprojection, controls the degree of tip rotation, preserves the natural contour of the nasal tip, respects the tip support mechanisms, increases the strength and stability of nasal tip complex, preserves or restores the normal lobule-to-columella proportion, and does not lead to alar flaring. However, the technique requires

  12. Application of Active Flow Control Technique for Gust Load Alleviation

    Institute of Scientific and Technical Information of China (English)

    XU Xiaoping; ZHU Xiaoping; ZHOU Zhou; FAN Ruijun

    2011-01-01

    A new gust load alleviation technique is presented in this paper based on active flow control.Numerical studies are conducted to investigate the beneficial effects on the aerodynamic characteristics of the quasi “Global Hawk” airfoil using arrays of jets during the gust process.Based on unsteady Navier-Stokes equations,the grid-velocity method is introduced to simulate the gust influence,and dynamic response in vertical gust flow perturbation is investigated for the airfoil as well.An unsteady surface transpiration boundary condition is enforced over a user specified portion of the airfoil's surface to emulate the time dependent velocity boundary conditions.Firstly,after applying this method to simulate typical NACA0006 airfoil gust response to a step change in the angle of attack,it shows that the indicial responses of the airfoil make good agreement with the exact theoretical values and the calculated values in references.Furthermore,gust response characteristic for the quasi “Global Hawk” airfoil is analyzed.Five kinds of flow control techniques are introduced as steady blowing,steady suction,unsteady blowing,unsteady suction and synthetic jets.The physical analysis of the influence on the effects of gust load alleviation is proposed to provide some guidelines for practice.Numerical results have indicated that active flow control technique,as a new technology of gust load alleviation,can affect and suppress the fluid disturbances caused by gust so as to achieve the purpose of gust load alleviation.

  13. VPLS Based Quality and Cost Control for Tennessee Eastman Process

    Institute of Scientific and Technical Information of China (English)

    宋凯; 王海清; 李平

    2005-01-01

    Product quality and operation cost control obtain increasing emphases in modern chemical system engineering. To improve the fault detection power of the partial least square (PLS) method for quality control, a new QRPV statistic is proposed in terms of the VP (variable importance in projection) indices of monitored process variables, which is significantly advanced over and different from the conventional Q statistic. QRPV is calculated only by the residuals of the remarkable process variables (RPVs). Therefore, it is the dominant relation between quality and RPV not all process variables (as in the case of the conventional PLS) that is monitored by this new VP-PLS (VPLS) method. The combination of QRPV and T2 statistics is applied to the quality and cost control of the Tennessee Eastman (TE) process, and weak faults can be detected as quickly as possible. Consequently, the product quality of TE process is guaranteed and operation costs are reduced.

  14. Mathematical modelling of the process of quality control of construction products

    Directory of Open Access Journals (Sweden)

    Pogorelov Vadim

    2017-01-01

    Full Text Available The study presents the results of years of research in the field of quality management of industrial production construction production, based on mathematical modelling techniques, process and results of implementing the developed programme of monitoring and quality control in the production process of the enterprise. The aim of this work is the presentation of scientific community of the practical results of mathematical modelling in application programs. In the course of the research addressed the description of the applied mathematical models, views, practical results of its application in the applied field to assess quality control. The authors used this mathematical model in practice. The article presents the results of applying this model. The authors developed the experimental software management and quality assessment by using mathematical modeling methods. The authors continue research in this direction to improve the diagnostic systems and quality management systems based on mathematical modeling methods prognostic and diagnostic processes.

  15. Advancement in modern approaches to mineral production quality control

    Science.gov (United States)

    Freidina, EV; Botvinnik, AA; Dvornikova, AN

    2017-02-01

    The natural resource potential of mineral deposits is represented by three categories: upside, attainable and investment. A modern methodology is proposed in this paper for production quality control, and its tools aimed at ensuring agreement between the product quality and the market requirements are described. The definitions of the costs of the product quality compliance and incompliance with the consumer requirements are introduced; the latter is suggested to use in evaluating resource potential of mineral deposits at a certain degree of probability.

  16. Positron plasma control techniques for the production of cold antihydrogen

    Science.gov (United States)

    Funakoshi, R.; Amoretti, M.; Bonomi, G.; Bowe, P. D.; Canali, C.; Carraro, C.; Cesar, C. L.; Charlton, M.; Doser, M.; Fontana, A.; Fujiwara, M. C.; Genova, P.; Hangst, J. S.; Hayano, R. S.; Jørgensen, L. V.; Kellerbauer, A.; Lagomarsino, V.; Landua, R.; Lodi Rizzini, E.; Macrì, M.; Madsen, N.; Manuzio, G.; Mitchard, D.; Montagna, P.; Posada, L. G. C.; Rotondi, A.; Testera, G.; Variola, A.; Venturelli, L.; van der Werf, D. P.; Yamazaki, Y.; Zurlo, N.

    2007-07-01

    An observation of a clear dependence of antihydrogen production on positron plasma shapes is reported. For this purpose a plasma control method has been developed combining the plasma rotating-wall technique with a mode diagnostic system. With the help of real-time and nondestructive observations, the rotating-wall parameters have been optimized. The positron plasma can be manipulated into a wide range of shapes (aspect ratio 6.5⩽α≲80 ) and densities (1.5×108⩽n≲7×109cm-3) within a short duration (25s) compatible with the ATHENA antihydrogen production cycle.

  17. Positron plasma control techniques for the production of cold antihydrogen

    CERN Document Server

    Funakoshi, R; Bonomi, G; Bowe, P D; Canali, C; Carraro, C; Cesar, C L; Charlton, M; Doser, M; Fontana, A; Fujiwara, M C; Genova, P; Hangst, J S; Hayano, R S; Jørgensen, L V; Kellerbauer, A G; Lagomarsino, V; Landua, R; Lodi-Rizzini, E; Macrì, M; Madsen, N; Manuzio, G; Mitchard, D; Montagna, P; Posada, L G C; Rotondi, A; Testera, G; Variola, A; Venturelli, L; Van der Werf, D P; Yamazaki, Y; Zurlo, N

    2007-01-01

    An observation of a clear dependence of antihydrogen production on positron plasma shapes is reported. For this purpose a plasma control method has been developed combining the plasma rotating-wall technique with a mode diagnostic system. With the help of real-time and nondestructive observations, the rotating-wall parameters have been optimized. The positron plasma can be manipulated into a wide range of shapes (aspect ratio 6.5≤α≲80) and densities (1.5×108≤n≲7×109 cm−3) within a short duration (25 s) compatible with the ATHENA antihydrogen production cycle.

  18. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications.

  19. Evaluation of spatial and temporal variations in marine sediments quality using multivariate statistical techniques.

    Science.gov (United States)

    Alvarez, Odalys Quevedo; Tagle, Margarita Edelia Villanueva; Pascual, Jorge L Gómez; Marín, Ma Teresa Larrea; Clemente, Ana Catalina Nuñez; Medina, Miriam Odette Cora; Palau, Raiza Rey; Alfonso, Mario Simeón Pomares

    2014-10-01

    Spatial and temporal variations of sediment quality in Matanzas Bay (Cuba) were studied by determining a total of 12 variables (Zn, Cu, Pb, As, Ni, Co, Al, Fe, Mn, V, CO₃²⁻, and total hydrocarbons (THC). Surface sediments were collected, annually, at eight stations during 2005-2008. Multivariate statistical techniques, such as principal component (PCA), cluster (CA), and lineal discriminant (LDA) analyses were applied for identification of the most significant variables influencing the environmental quality of sediments. Heavy metals (Zn, Cu, Pb, V, and As) and THC were the most significant species contributing to sediment quality variations during the sampling period. Concentrations of V and As were determined in sediments of this ecosystem for the first time. The variation of sediment environmental quality with the sampling period and the differentiation of samples in three groups along the bay were obtained. The usefulness of the multivariate statistical techniques employed for the environmental interpretation of a limited dataset was confirmed.

  20. Forward SCT Module Assembly and Quality Control at IFIC Valencia

    CERN Document Server

    Mitsou, V A; Civera, J V; Costa, M J; Escobar, C; Fuster, J; García, C; García-Navarro, J E; González, F; González-Sevilla, S; Lacasta, C; Llosá, G; Martí i García, S; Miñano, M; Modesto, P; Nácher, J; Rodríguez-Oliete, R; Sánchez, F J; Sospedra, L; Strachko, V

    2007-01-01

    This note discusses the assembly and the quality control tests of 282 forward detector modules for the ATLAS Semiconductor Tracker assembled at the Instituto de Fisica Corpuscular (IFIC) in Valencia. The construction and testing procedures are outlined and the laboratory equipment is briefly described. Emphasis is given on the module quality achieved in terms of mechanical and electrical stability.

  1. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Science.gov (United States)

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  2. Academic Quality Control in Nigerian Universities: Exploring Lecturers' Perceptions

    Science.gov (United States)

    Obiekezie, E. O.; Ejemot-Nwadiaro, R. I.; Essien, M. I.; Timothy, A. Essien

    2014-01-01

    The level of job performance, international comparability and competitiveness of Nigerian university graduates are burning issues. Consequently, the academic quality of Nigerian universities has come under severe criticism. Since university lecturers are key players in quality control in universities, this study explored their perceptions of…

  3. Quality control for diagnostic oral microbiology laboratories in European countries

    NARCIS (Netherlands)

    Rautemaa-Richardson, R.; van der Reijden, W.A.; Dahlen, G.; Smith, A.J.

    2011-01-01

    Participation in diagnostic microbiology internal and external quality control (QC) processes is good laboratory practice and an essential component of a quality management system. However, no QC scheme for diagnostic oral microbiology existed until 2009 when the Clinical Oral Microbiology (COMB)

  4. Quality Changes of Frozen Meat During Storage and Control Measures

    Institute of Scientific and Technical Information of China (English)

    DU Jiangping

    2010-01-01

    The frozen is a common method of meat storage, generally applications in meat industrial. However, the quality of meat still have taken place changes even in the low temperature, This article discussion on the changes of frozen meat quality during freezing storage, and give the corresponding control measures.

  5. Quality Control Review of the Defense Logistics Agency Audit Organization

    Science.gov (United States)

    2014-12-19

    all auditors are required to follow, and established an internal quality assurance division that performs ongoing, periodic assessments of work...audit organization performing audits or attestation engagements or both have an appropriate internal quality control system in place and undergo an...2010, the DLA OIG addressed our recommendation to implement official policies and procedures, which all auditors are required to follow. The DLA

  6. Plan quality and treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy.

    Science.gov (United States)

    Clark, Grant M; Popple, Richard A; Prendergast, Brendan M; Spencer, Sharon A; Thomas, Evan M; Stewart, John G; Guthrie, Barton L; Markert, James M; Fiveash, John B

    2012-01-01

    To demonstrate plan quality and provide a practical, systematic approach to the treatment planning technique for single isocenter cranial radiosurgery with volumetric modulated arc therapy (VMAT; RapidArc, Varian Medical systems, Palo Alto, CA). Fifteen patients with 1 or more brain metastases underwent single isocenter VMAT radiosurgery. All plans were normalized to deliver 100% of the prescription dose to 99%-100% of the target volume. All targets per plan were treated to the same dose. Plans were created with dose control tuning structures surrounding targets to maximize conformity and dose gradient. Plan quality was evaluated by calculation of conformity index (CI = 100% isodose volume/target volume) and homogeneity index (HI = maximum dose/prescription dose) scores for each target and a Paddick gradient index (GI = 50% isodose volume/100% isodose volume) score for each plan. The median number of targets per patient was 2 (range, 1-5). The median number of non-coplanar arcs utilized per plan was 2 (range, 1- 4). Single target plans were created with 1 or 2 non-coplanar arcs while multitarget plans utilized 2 to 4 non-coplanar arcs. Prescription doses ranged from 5-16 Gy in 1-5 fractions. The mean conformity index was 1.12 (± SD, 0.13) and the mean HI was 1.44 (± SD, 0.11) for all targets. The mean GI per plan was 3.34 (± SD, 0.42). We have outlined a practical approach to cranial radiosurgery treatment planning using the single isocenter VMAT platform. One or 2 arc single isocenter plans are often adequate for treatment of single targets, while 2-4 arcs may be more advantageous for multiple targets. Given the high plan quality and extreme clinical efficiency, this single isocenter VMAT approach will continue to become more prevalent for linac-based radiosurgical treatment of 1 or more intracranial targets and will likely replace multiple isocenter techniques. Copyright © 2012 American Society for Radiation Oncology. Published by Elsevier Inc. All rights

  7. Handbook of software quality assurance techniques applicable to the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, J.L.; Wilburn, N.P.

    1987-08-01

    Pacific Northwest Laboratory is conducting a research project to recommend good engineering practices in the application of 10 CFR 50, Appendix B requirements to assure quality in the development and use of computer software for the design and operation of nuclear power plants for NRC and industry. This handbook defines the content of a software quality assurance program by enumerating the techniques applicable. Definitions, descriptions, and references where further information may be obtained are provided for each topic.

  8. Cold plasma: Quality control and regulatory considerations

    Science.gov (United States)

    In recent years, cold plasma has emerged as a promising antimicrobial treatment for fresh and fresh-cut produce, nuts, spices, seeds, and other foods. Research has demonstrated effective control of human pathogens such as Salmonella, Listeria monocytogenes, Escherichia coli O157:H7, norovirus, and o...

  9. Randomized Dynamical Decoupling Techniques for Coherent Quantum Control

    CERN Document Server

    Viola, L; Viola, Lorenza; Santos, Lea F.

    2006-01-01

    The need for strategies able to accurately manipulate quantum dynamics is ubiquitous in quantum control and quantum information processing. We investigate two scenarios where randomized dynamical decoupling techniques become more advantageous with respect to standard deterministic methods in switching off unwanted dynamical evolution in a closed quantum system: when dealing with decoupling cycles which involve a large number of control actions and/or when seeking long-time quantum information storage. Highly effective hybrid decoupling schemes, which combine deterministic and stochastic features are discussed, as well as the benefits of sequentially implementing a concatenated method, applied at short times, followed by a hybrid protocol, employed at longer times. A quantum register consisting of a chain of spin-1/2 particles interacting via the Heisenberg interaction is used as a model for the analysis throughout.

  10. Demand Management Based on Model Predictive Control Techniques

    Directory of Open Access Journals (Sweden)

    Yasser A. Davizón

    2014-01-01

    Full Text Available Demand management (DM is the process that helps companies to sell the right product to the right customer, at the right time, and for the right price. Therefore the challenge for any company is to determine how much to sell, at what price, and to which market segment while maximizing its profits. DM also helps managers efficiently allocate undifferentiated units of capacity to the available demand with the goal of maximizing revenue. This paper introduces control system approach to demand management with dynamic pricing (DP using the model predictive control (MPC technique. In addition, we present a proper dynamical system analogy based on active suspension and a stability analysis is provided via the Lyapunov direct method.

  11. Digital control of high performance aircraft using adaptive estimation techniques

    Science.gov (United States)

    Van Landingham, H. F.; Moose, R. L.

    1977-01-01

    In this paper, an adaptive signal processing algorithm is joined with gain-scheduling for controlling the dynamics of high performance aircraft. A technique is presented for a reduced-order model (the longitudinal dynamics) of a high performance STOL aircraft. The actual controller views the nonlinear behavior of the aircraft as equivalent to a randomly switching sequence of linear models taken from a preliminary piecewise-linear fit of the system nonlinearities. The adaptive nature of the estimator is necessary to select the proper sequence of linear models along the flight trajectory. Nonlinear behavior is approximated by effective switching of the linear models at random times, with durations reflecting aircraft motion in response to pilot commands.

  12. Problem-solving and developing quality management methods and techniques on the example of automotive industry

    Directory of Open Access Journals (Sweden)

    Jacek Łuczak

    2015-12-01

    Full Text Available The knowledge about methods and techniques of quality management together with their effective use can be definitely regarded as an indication of high organisational culture. Using such methods and techniques in an effective way can be attributed to certain level of maturity, as far as the quality management system in an organisation is concerned. There is in the paper an analysis of problem-solving methods and techniques of quality management in the automotive sector in Poland. The survey was given to the general population, which in case of the study consisted of companies operating in Poland that had certified quality management systems against ISO/TS 16949. The results of the conducted survey and the conclusions of the author can show actual and potential OEM suppliers (both 1st and 2nd tier in which direction their strategies for development and improvement of quality management systems should go in order to be effective. When the universal character of methods and techniques used in the surveyed population of companies is taken into consideration, it can be assumed that the results of the survey are also universal for all organisations realising the TQM strategy. The results of the research confirmed that methods which are also the basis for creating key system documents are the most relevant ones, i.e. flowcharts and FMEA, and moreover process monitoring tools (SPC and problem solving methods -above all 8D.

  13. Descriptive study of the quality control in mammography; Estudio descriptivo del control de calidad en mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M. [UAM, Xochimilco 14000 Mexico D.F. (Mexico)

    2005-07-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  14. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  15. Research Ship Healy Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. NOAA Ship David Starr Jordan Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship David Starr Jordan Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  18. NOAA Ship Henry B. Bigelow Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Henry B. Bigelow Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  20. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. Research Ship Laurence M. Gould Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Laurence M. Gould Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  2. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  3. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System (SAMOS)...

  5. Research Ship Roger Revelle Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Roger Revelle Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  6. Research Ship T. G. Thompson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship T. G. Thompson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  7. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  8. Research Ship Southern Surveyor Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Southern Surveyor Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  9. Research Ship New Horizon Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship New Horizon Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  10. NOAA Ship Okeanos Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Okeanos Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  11. Research Ship Nathaniel B. Palmer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Nathaniel B. Palmer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  12. Research Ship Aurora Australis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Aurora Australis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  13. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  14. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  15. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. Research Ship Melville Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. NOAA Ship Bell M. Shimada Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Bell M. Shimada Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  19. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  20. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. Research Ship Robert Gordon Sproul Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Robert Gordon Sproul Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and...

  2. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  3. Research Ship Atlantic Explorer Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantic Explorer Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  4. NOAA Ship Oscar Elton Sette Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Elton Sette Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic...

  5. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  7. Ensuring quality control of forensic accounting for efficient and ...

    African Journals Online (AJOL)

    Ensuring quality control of forensic accounting for efficient and effective ... has taken the center stage in every discussion whether in business or social. ... To ensure a valid conclusion of the study the ex-post facto research design was applied.

  8. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. Switching Control of Wind Turbine Sub-Controllers Based on an Active Disturbance Rejection Technique

    Directory of Open Access Journals (Sweden)

    Yancai Xiao

    2016-10-01

    Full Text Available Wind power generation systems require complex control systems with multiple working conditions and multiple controllers. Under different operating conditions, switching without disturbancebetweenthesub-controllersplaysacriticalroleinensuringthestabilityofpowersystems. The sub-controllers of two typical cases in the permanent magnet direct drive (PMDD wind turbine running process are studied, one is the proportional integral (PI controller in the maximum power points tracking (MPPT stage, the other is the fuzzy pitch angle controller in the constant power stage. The switching strategy of the two sub-controllers is the emphasis in this research. Based on the active disturbance rejection control (ADRC, the switching mode of the sub-controllers is proposed, which can effectively restrain the sudden changes of the rotor current during the switching process, and improve the quality of power generation. The feasibility and effectiveness of the sub-controller switching strategy is verified by Matlab/Simulink simulation for a 2 MW PMDD wind turbine.

  10. Mechanisms for quality control of misfolded transmembrane proteins

    OpenAIRE

    Houck, Scott A.; Cyr, Douglas M.

    2011-01-01

    To prevent the accumulation of misfolded and aggregated proteins, the cell has developed a complex network of cellular quality control (QC) systems to recognize misfolded proteins and facilitate their refolding or degradation. The cell faces numerous obstacles when performing quality control on transmembrane proteins. Transmembrane proteins have domains on both sides of a membrane and QC systems in distinct compartments must coordinate to monitor the folding status of the protein. Additionall...

  11. Analysis of Information Quality in event triggered Smart Grid Control

    DEFF Research Database (Denmark)

    Kristensen, Thomas le Fevre; Olsen, Rasmus Løvenstein; Rasmussen, Jakob Gulddahl

    2015-01-01

    dependability of existing networks. We develop models for network delays and information dynamics, and uses these to model information quality for three given information access schemes in an event triggered control scenario. We analyse the impact of model parameters, and show how optimal choice of information...... access scheme depends on network conditions as well as trade-offs between information quality, network resources and control reactivity....

  12. Quality control of injection moulded micro mechanical parts

    DEFF Research Database (Denmark)

    Gasparin, Stefania; Tosello, Guido; Hansen, Hans Nørgaard

    2009-01-01

    Quality control of micro components is an increasing challenge. Smaller mechanical parts are characterized by smaller tolerance to be verified. This paper focuses on the dimensional verification of micro injection moulded components selected from an industrial application. These parts are measured...... using an Optical Coordinate Measuring Machine (OCMM), which guarantees fast surface scans suitable for in line quality control. The uncertainty assessment of the measurements is calculated following the substitution method. To investigate the influence parameters in optical coordinate metrology two...

  13. Valuing Health-Related Quality of Life: A Review of Health State Valuation Techniques

    OpenAIRE

    Colin Green; John Brazier; Mark Deverill

    2000-01-01

    Given the growing need to value health-related quality of life, a review of the literature relating to health state valuation techniques was undertaken to appraise the current theoretical and empirical evidence available to inform on the techniques, to identify consensus, identify disagreement and identify important areas for future research. A systematic search of the literature was conducted, covering standard gamble (SG), time trade-off (TTO), visual analogue scale (VAS), magnitude estimat...

  14. Evolutionary biology and genetic techniques for insect control.

    Science.gov (United States)

    Leftwich, Philip T; Bolton, Michael; Chapman, Tracey

    2016-01-01

    The requirement to develop new techniques for insect control that minimize negative environmental impacts has never been more pressing. Here we discuss population suppression and population replacement technologies. These include sterile insect technique, genetic elimination methods such as the release of insects carrying a dominant lethal (RIDL), and gene driving mechanisms offered by intracellular bacteria and homing endonucleases. We also review the potential of newer or underutilized methods such as reproductive interference, CRISPR technology, RNA interference (RNAi), and genetic underdominance. We focus on understanding principles and potential effectiveness from the perspective of evolutionary biology. This offers useful insights into mechanisms through which potential problems may be minimized, in much the same way that an understanding of how resistance evolves is key to slowing the spread of antibiotic and insecticide resistance. We conclude that there is much to gain from applying principles from the study of resistance in these other scenarios - specifically, the adoption of combinatorial approaches to minimize the spread of resistance evolution. We conclude by discussing the focused use of GM for insect pest control in the context of modern conservation planning under land-sparing scenarios.

  15. Production control system specified quality sausage products

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  16. Quality control based on electrical resistivity measurements

    OpenAIRE

    Ferreira, Rui Miguel; Jalali, Said

    2006-01-01

    The electrical resistivity of concrete is one of the main parameters controlling the initiation and propagation of reinforcement corrosion. It is common knowledge that concrete electrical resistivity is mainly dependent on the w/c ratio (pore connectivity), volume and type of cement, temperature and the moisture. This research work studies the effect of specimen shape and temperature of measurement on electrical resistivity measurements of concrete using the four-point Werner electrode. In ad...

  17. Role of Protein Quality Control Failure in Alcoholic Hepatitis Pathogenesis

    Directory of Open Access Journals (Sweden)

    Samuel W. French

    2017-02-01

    Full Text Available The mechanisms of protein quality control in hepatocytes in cases of alcoholic hepatitis (AH including ufmylation, FAT10ylation, metacaspase 1 (Mca1, ERAD (endoplasmic reticulum-associated degradation, JUNQ (juxta nuclear quality control, IPOD (insoluble protein deposit autophagocytosis, and ER stress are reviewed. The Mallory–Denk body (MDB formation develops in the hepatocytes in alcoholic hepatitis as a consequence of the failure of these protein quality control mechanisms to remove misfolded and damaged proteins and to prevent MDB aggresome formation within the cytoplasm of hepatocytes. The proteins involved in the quality control pathways are identified, quantitated, and visualized by immunofluorescent antibody staining of liver biopsies from patients with AH. Quantification of the proteins are achieved by measuring the fluorescent intensity using a morphometric system. Ufmylation and FAT10ylation pathways were downregulated, Mca1 pathways were upregulated, autophagocytosis was upregulated, and ER stress PERK (protein kinase RNA-like endoplasmic reticulum kinase and CHOP (CCAAT/enhancer-binding protein homologous protein mechanisms were upregulated. In conclusion: Despite the upregulation of several pathways of protein quality control, aggresomes (MDBs still formed in the hepatocytes in AH. The pathogenesis of AH is due to the failure of protein quality control, which causes balloon-cell change with MDB formation and ER stress.

  18. Various power quality challenges and solution techniques using FACTS technology for power system

    Science.gov (United States)

    Soni, J. Sandeep; Jangalwa, N. K.; Gupta, R.; Palwalia, D. K.

    2016-03-01

    This paper presents a comprehensive review on the various power quality problems and various solution techniques using FACTS in Power system. The term "Power Quality" is a broad concept and its meaning is taken different by different peoples. It is associated with electrical transmission, distribution and utilization systems those are having experience of any Voltage, current or frequency divergence from normal operation. Due to power quality problems industries have to invest large amount for mitigation of Voltage sags, distortions, harmonics and short term interruptions/disturbances etc. In paper authors tried to cover various possible sources and compensation methods of reactive power in power system.

  19. Experience with ISO quality control in assisted reproductive technology.

    Science.gov (United States)

    Alper, Michael M

    2013-12-01

    Assisted reproductive technology (ART) programs are complex organizations requiring the integration of multiple disciplines. ISO 9001:2008 is a quality management system that is readily adaptable to an ART program. The value that ISO brings to the entire organization includes control of documents, clear delineation of responsibilities of staff members, documentation of the numerous processes and procedures, improvement in tracking and reducing errors, and overall better control of systems. A quality ART program sets quality objectives and monitors their progress. ISO provides a sense of transparency within the organization and clearer understanding of how service is provided to patients. Most importantly, ISO provides the framework to allow for continual improvement.

  20. A Technique for Quality Evaluation of E-Learning from Developers Perspective

    Directory of Open Access Journals (Sweden)

    Majdi Abdellatief

    2011-01-01

    Full Text Available Problem statement: E-learning is gaining more acceptance as days pass because it provides learning opportunity any time and in any place. Different people have different preferences in terms of learning style such as reading text, listing audio or video, speaking and communication. To support these different learning preferences, there is need for multiple e-learning delivery methods and teaching techniques. Furthermore, there are many stakeholders of e-learning systems such as system developers, administrators, instructors, instructional designers, multimedia designers, online facilitators, independent evaluators. Whose views are important indicators for a complete e-learning system evaluation, but the most important views of e-learning quality are user view, developer’s view and manger’s view. Approach: The main aim of this study is to propose a new technique to evaluate e-learning website quality from developer’s view. To achieve our objective an extensive study on related resources was conducted. Our technique adopts the weights of quality characteristics which are obtained by carefully selected questionnaires’ from professional developers. We also present the evaluation process using AHP technique and the result of trial evaluation for validation of our technique. Result: We proposed four quality characteristics named Service Content, System Functionality, Information Technology and System Reliability. We further, proposed 11 subcharacteristics with its attributes by following the structure of standard IOS/IEC 912. Conclusion: Our results show that the proposed technique could be useful and effective for ensuring that high quality systems are developed.

  1. Quality control throughout the production process of infant food.

    Science.gov (United States)

    Hamrin, Pia; Hoeft, Birgit

    2012-01-01

    The manufacture of infant food is a highly complex process and needs an effective quality control beyond classical in-process parameters and a final microbiological analysis. To ensure a safe end -product, various tools, such as the Hazard Analysis Critical Control Points (HACCP), have been developed to facilitate the management of food safety. Every single infant formula ingredient must have an excellent quality and safety approach because even if an ingredient is used in very small quantities in a single product, serious consequences may arise if the quality and product safety are not taken seriously by the ingredient manufacturer. The purpose of this article was twofold: firstly, to briefly describe existing Quality Management Systems and, secondly, to highlight the consequences of non-quality.

  2. Quality controls and security features for U.S. currency and postage stamps

    Science.gov (United States)

    Grimsley, Max; Hess, James E.; Poulsen, Mark; Rankin, Ken; Curtis, David

    2000-04-01

    The US Bureau of Engraving and Printing produces over 9 billion Federal Reserve notes per year. Each note must maintain unfirm consistency for both security features and print quality. The quality control process necessary to assure the uniform nature of US currency requires a significant multi-tiered approach. Based on innovative optoelectronic techniques, individual security features are examined as a critical element during each phase of the production process. Print quality standards must also be strictly maintained and monitored to assure the uniformity of the most popular printed item in the world. This presentation describes the approach and some of the techniques developed and implemented in-house to carry out the necessary monitoring and control.

  3. Dosimetric systems developed in Brazil for the radiation processes quality control

    Energy Technology Data Exchange (ETDEWEB)

    Galante, Ana Maria Sisti; Campos, Leticia Lucente, E-mail: sgalante@ipen.b, E-mail: lcrodri@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    In order to apply new technologies to the industrial processing of materials aiming economy, efficiency, speed and high quality, ionizing radiation has been used in medicine, archaeology, chemistry, food preservation and other areas. For this reason, the dosimetry area looks for improve current dosimeters and develop new materials for application on quality control of these processes. In Brazil, the research in the dosimetry area occurs with great speed providing many different dosimetric systems. The chemical dosimetry is the most used technique in routine dosimetry, which requires fast and accurate responses. This technique involves determination of absorbed dose by measuring chemical changes radiation induced in the materials. Different dosimetric systems were developed at IPEN for application on radiation process quality and all of them present excellent results; the low cost of these materials allows a more effective dose control, therefore, a larger area or volume can be monitored. (author).

  4. Quality control of cemented waste forms

    Energy Technology Data Exchange (ETDEWEB)

    Slate, L.J.

    1994-12-31

    To insure that cemented radwaste remains immobilized after disposal, certain standards have been set in Europe by the Commission of the European Communities. One such standard is compressive strength. If the compressive strength can be predicted during the early curing stages, time and money can be saved and the quality of the final waste form guaranteed. It was determined that the 7- and 28-day compressive strength from radwaste cementation can be predicted during the mixing and early curing stages by at least three methods. The three that were studied were maturity, rheology, and impedance. Maturity is a temperature-to-time measurement, rheology is a shear stress-to-shear rate measurement, and impedance is the opposition offered to the flow of alternating current. These three methods were employed on five different cemented radwaste concentrations with three different water-to-cement ratios; thus, a total of 15 different mix designs were considered. The results showed that the impedance was the easiest to employ for an on-line process. The results of the impedance method showed a very good relationship between impedance and water-to-cement ratio; therefore, an accurate prediction of compressive strength of cemented radwaste can be drawn from this method. The results of the theology method were very good. The method showed that concrete conforms to the Bingham plastic rheologic model, and the theology method can be used to predict the compressive strength of cemented radwaste, but may be too cumbersome. The results of the maturity method were shown to be limited in accuracy for determining compressive strength.

  5. Quality control of cast brake discs

    Directory of Open Access Journals (Sweden)

    M. Stawarz

    2008-04-01

    Full Text Available The largest industrial application so far have the gray cast irons which are characterized by low tensile and bending strength, while at the same time they have good ultimate comprehensive strength. Additionally, the fatigue strength of gray cast irons is comparatively low and they are only to some extend sensitive for the surface waters effects. Cast iron is the material, which is comparatively easy to be processed, and for this reason – it is not expensive. Brake discs are exploited in particularly hard conditions. They must be resistant both against the thermal fatigue and abrasion wearing (at dry friction as well as against seizing, corrosion and mechanical load [1-3]. The gray cast iron, better than other materials, fulfills all the requirements necessary for making the material for the casts resistant against such tough conditions. This work reflects the researches aiming to define the quality of cast brake discs (ventilated and non-ventilated ones upon a period of their exploitation in real conditions. The following researches were performed: evaluations of the disc surface condition, measurement of disc thickness, examination of run – out flank and metallographic analysis. In order to more detailed recognition of mechanisms and reasons of brake discs wearing in real conditions, one should conduct additional examinations: computer analysis of the microstructure, chemical composition analysis, etc., as well as study of the technology of their production in foundries, where they are manufactured [4]. By obtaining the full set of the mentioned above data one can draw final conclusions and remove causes of possible defects.

  6. Quality control and quality assurance of micromegas readout boards for the ATLAS New Small Wheel

    CERN Document Server

    Nanda, Amit

    2016-01-01

    The resistive anode boards of the Micromegas detectors for ATLAS NSW upgrade, will be produced in industries. The anode boards will be thoroughly evaluated at CERN following a detailed quality control and quality assurance (QA/QC) procedure. The report describes thoroughly the procedures and the design of a small QC tool for easier measurements of electrical properties of the readout boards.

  7. Functional method implementation of post-crop conservation of melon cantaloupe, using ionizing radiation as quality control technique in productive chain; Implantacao de metodo funcional de conservacao pos-colheita de meloes cantaloupe, utilizando as radiacoes ionizantes como tecnica de controle de qualidade na cadeia produtiva

    Energy Technology Data Exchange (ETDEWEB)

    Siqueira, Alessandra A.Z. Cozzo de; Matraia, Clarice; Walder, Julio Marcos M. [Centro de Energia Nuclear na Agricultura (CENA), Piracicaba, SP (Brazil). Dept. de Irradiacao de Alimentos e Radioentomologia]. E-mail: aazcozzo@cena.usp.br; Spoto, Marta H.F.; Silva, Paula P.M. da; Maretti, Marina S. [Escola Superior de Agricultura Luiz de Queiroz, Piracicaba, SP (Brazil). Dept. de Agroindustria, Alimentos e Nutricao

    2005-07-01

    The Brazilian fruit culture is an alternative to minimize the lack-of-food problem using management and post harvest appropriate techniques. Gamma radiation technology is a possible technique used for food, enlarging its shelf-life, eliminating pathogenic microorganisms and in the quarantine treatment. The irradiation with seven doses (150,300,450,600,750 and 900 Gy) was used in Cantaloupe melon (Cucumis melon var. Cantaloupensis) aiming to establish the minimum, maximum and ideal doses, according to Brazilian laws, analyzing weight, color, firmness, pulp and juice quantity and sensory aspects, using the Difference Control Test. The results indicate that storage influenced significantly the weight, color and pulp quantity parameters. Doses higher than 450 Gy however influenced the firmness, juice quantity and sensory aspects characteristics. These results are indicating that the minimum dose was 150 Gy, the maximum dose was 900 Gy and the ideal dose for the quarantine treatment and to increase shelf-life of the Cantaloupe melon was 450 Gy. The data obtained allowed us to conclude that the ionizing radiation can increase the shelf-life of the Cantaloupe melon using doses up to 450 Gy making it proper to exportation. (author)

  8. Beaconless adaptive-optics technique for HEL beam control

    Science.gov (United States)

    Khizhnyak, Anatoliy; Markov, Vladimir

    2016-05-01

    Effective performance of forthcoming laser systems capable of power delivery on a distant target requires an adaptive optics system to correct atmospheric perturbations on the laser beam. The turbulence-induced effects are responsible for beam wobbling, wandering, and intensity scintillation, resulting in degradation of the beam quality and power density on the target. Adaptive optics methods are used to compensate for these negative effects. In its turn, operation of the AOS system requires a reference wave that can be generated by the beacon on the target. This report discusses a beaconless approach for wavefront correction with its performance based on the detection of the target-scattered light. Postprocessing of the beacon-generated light field enables retrieval and detailed characterization of the turbulence-perturbed wavefront -data that is essential to control the adaptive optics module of a high-power laser system.

  9. Chronic Low Quality Sleep Impairs Postural Control in Healthy Adults.

    Science.gov (United States)

    Furtado, Fabianne; Gonçalves, Bruno da Silva B; Abranches, Isabela Lopes Laguardia; Abrantes, Ana Flávia; Forner-Cordero, Arturo

    2016-01-01

    The lack of sleep, both in quality and quantity, is an increasing problem in modern society, often related to workload and stress. A number of studies have addressed the effects of acute (total) sleep deprivation on postural control. However, up to date, the effects of chronic sleep deficits, either in quantity or quality, have not been analyzed. Thirty healthy adults participated in the study that consisted of registering activity with a wrist actigraph for more than a week before performing a series of postural control tests. Sleep and circadian rhythm variables were correlated and the sum of activity of the least active 5-h period, L5, a rhythm variable, obtained the greater coefficient value with sleep quality variables (wake after sleep onset WASO and efficiency sleep). Cluster analysis was performed to classify subjects into two groups based on L5 (low and high). The balance tests scores used to asses postural control were measured using Biodex Balance System and were compared between the two groups with different sleep quality. The postural tests were divided into dynamic (platform tilt with eyes open, closed and cursor) and static (clinical test of sensory integration). The results showed that during the tests with eyes closed, the group with worse sleep quality had also worse postural control performance. Lack of vision impairs postural balance more deeply in subjects with chronic sleep inefficiency. Chronic poor sleep quality impairs postural control similarly to total sleep deprivation.

  10. Quality control of the documentation process in electronic economic activities

    Directory of Open Access Journals (Sweden)

    Krutova A.S.

    2017-06-01

    Full Text Available It is proved that the main tool that will provide adequate information resources e economic activities of social and economic relations are documenting quality control processes as the basis of global information space. Directions problems as formation evaluation information resources in the process of documentation, namely development tools assess the efficiency of the system components – qualitative assessment; development of mathematical modeling tools – quantitative evaluation. A qualitative assessment of electronic documentation of economic activity through exercise performance, efficiency of communication; document management efficiency; effectiveness of flow control operations; relationship management effectiveness. The concept of quality control process documents electronically economic activity to components which include: the level of workflow; forms adequacy of information; consumer quality documents; quality attributes; type of income data; condition monitoring systems; organizational level process documentation; attributes of quality, performance quality consumer; type of management system; type of income data; condition monitoring systems. Grounded components of the control system electronic document subjects of economic activity. Detected components IT-audit management system economic activity: compliance audit; audit of internal control; detailed multilevel analysis; corporate risk assessment methodology. The stages and methods of processing electronic transactions economic activity during condition monitoring of electronic economic activity.

  11. [Pharmaceutical product quality control and good manufacturing practices].

    Science.gov (United States)

    Hiyama, Yukio

    2010-01-01

    This report describes the roles of Good Manufacturing Practices (GMP) in pharmaceutical product quality control. There are three keys to pharmaceutical product quality control. They are specifications, thorough product characterization during development, and adherence to GMP as the ICH Q6A guideline on specifications provides the most important principles in its background section. Impacts of the revised Pharmaceutical Affairs Law (rPAL) which became effective in 2005 on product quality control are discussed. Progress of ICH discussion for Pharmaceutical Development (Q8), Quality Risk Management (Q9) and Pharmaceutical Quality System (Q10) are reviewed. In order to reconstruct GMP guidelines and GMP inspection system in the regulatory agencies under the new paradigm by rPAL and the ICH, a series of Health Science studies were conducted. For GMP guidelines, product GMP guideline, technology transfer guideline, laboratory control guideline and change control system guideline were written. For the GMP inspection system, inspection check list, inspection memo and inspection scenario were proposed also by the Health Science study groups. Because pharmaceutical products and their raw materials are manufactured and distributed internationally, collaborations with other national authorities are highly desired. In order to enhance the international collaborations, consistent establishment of GMP inspection quality system throughout Japan will be essential.

  12. [Development of full-quantified fingerprint for quality control of traditional Chinese medicines].

    Science.gov (United States)

    Feng, Jiatao; Jin, Yu; Wang, Jincheng; Xiao, Yuansheng; Liang, Xinmiao

    2008-03-01

    Full-quantified fingerprint technique combines the fingerprint technique and multiple-target determination technique. The development of full-quantified fingerprint technique includes the preparation of full-quantified fraction, the quality control in preparation process with fingerprint technique and determination of products. In this paper, the full-quantified fractions of Salvia miltiorrhiza Bge. were prepared by water extraction, deposition with the ethanol, membrane filter, separation on macroporous resin and separation with preparative high performance liquid chromatography (HPLC). Fingerprint technique was used to test the reproducibility of preparation. Three ingredients, protocatechualdehyde, rosmarinic acid, salvianolic acid B were determined and the sum of their contents was more than 50%. The pharmaceutical active compounds were taken as the preparation target. The impurities were removed effectively by multiple preparations, and the specification of full-quantified fraction was improved greatly.

  13. Information Landscaping: Information Mapping, Charting, Querying and Reporting Techniques for Total Quality Knowledge Management.

    Science.gov (United States)

    Tsai, Bor-sheng

    2003-01-01

    Total quality management and knowledge management are merged and used as a conceptual model to direct and develop information landscaping techniques through the coordination of information mapping, charting, querying, and reporting. Goals included: merge citation analysis and data mining, and apply data visualization and information architecture…

  14. Non-Destructive and rapid evaluation of staple foods quality by using spectroscopic techniques: A review.

    Science.gov (United States)

    Su, Wen-Hao; He, Hong-Ju; Sun, Da-Wen

    2017-03-24

    Staple foods, including cereals, legumes, and root/tuber crops, dominate the daily diet of humans by providing valuable proteins, starch, oils, minerals, and vitamins. Quality evaluation of staple foods is primarily carried out on sensory (e.g. external defect, color), adulteration (e.g. species, origin), chemical (e.g. starch, proteins), mycotoxin (e.g. Fusarium toxin, aflatoxin), parasitic infection (e.g. weevil, beetle), and internal physiological (e.g. hollow heart, black heart) aspects. Conventional methods for the quality assessment of staple foods are always laborious, destructive, and time-consuming. Requirements for online monitoring of staple foods have been proposed to encourage the development of rapid, reagentless, and noninvasive techniques. Spectroscopic techniques, such as visible-infrared spectroscopy, Raman spectroscopy, nuclear magnetic resonance spectroscopy, and spectral imaging, have been introduced as promising analytical tools and applied for the quality evaluation of staple foods. This review summarizes the recent applications and progress of such spectroscopic techniques in determining various qualities of staple foods. Besides, challenges and future trends of these spectroscopic techniques are also presented.

  15. Information Landscaping: Information Mapping, Charting, Querying and Reporting Techniques for Total Quality Knowledge Management.

    Science.gov (United States)

    Tsai, Bor-sheng

    2003-01-01

    Total quality management and knowledge management are merged and used as a conceptual model to direct and develop information landscaping techniques through the coordination of information mapping, charting, querying, and reporting. Goals included: merge citation analysis and data mining, and apply data visualization and information architecture…

  16. Time-Based Dithering Algorithm and Frame Rate Control Technique for STN LCD Controller

    Institute of Scientific and Technical Information of China (English)

    LEIJianming; ZOUXuechen

    2004-01-01

    Time-based dithering algorithm and Frame rate control (FRC) technique applied to the STN liquid crystal display controller are presented. The dithering unit performs time-based dithering algorithm on pixel data to advantageously increase smoothness of an image displayed. The frame rate control unit is responsive to the dithering unit and performs frame rate controlling to generate more gray-shades, which may reduce flicker and visual artifacts. Results show that the gray shades displayed on images can be up to 256 for monochrome STN LCD panels or 2563 colors for color STN LCD panels respectively by using timebased dithering algorithm and frame rate control technique if each encoded pixel data is 8 bits. The images displayed on the STN liquid crystal display can get desirable grayshades and very little flicker and visual artifacts.

  17. Using geophysical techniques to control in situ thermal remediation

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, S.; Daily, W.; Ramirez, A.; Wilt, M. [Lawrence Livermore National Lab., CA (United States); Goldman, R.; Kayes, D.; Kenneally, K.; Udell, K. [California Univ., Berkeley, CA (United States); Hunter, R. [Infraseismic, Inc., Bakersfield, CA (United States)

    1994-01-22

    Monitoring the thermal and hydrologic processes that occur during thermal environmental remediation programs in near real-time provides essential information for controlling the process. Geophysical techniques played a crucial role in process control as well as for characterization during the recent Dynamic Underground Stripping Project demonstration in which several thousand gallons of gasoline were removed from heterogeneous soils both above and below the water table. Dynamic Underground Stripping combines steam injection and electrical heating for thermal enhancement with ground water pumping and vacuum extraction for contaminant removal. These processes produce rapid changes in the subsurface properties including changes in temperature fluid saturation, pressure and chemistry. Subsurface imaging methods are used to map the heated zones and control the thermal process. Temperature measurements made in wells throughout the field reveal details of the complex heating phenomena. Electrical resistance tomography (ERT) provides near real-time detailed images of the heated zones between boreholes both during electrical heating and steam injection. Borehole induction logs show close correlation with lithostratigraphy and, by identifying the more permeable gravel zones, can be used to predict steam movement. They are also useful in understanding the physical changes in the field and in interpreting the ERT images. Tiltmeters provide additional information regarding the shape of the steamed zones in plan view. They were used to track the growth of the steam front from individual injectors.

  18. 40 CFR 81.112 - Charleston Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.112 Charleston Intrastate Air Quality Control Region. The Charleston Intrastate Air Quality Control Region (South Carolina) consists of the territorial area encompassed by the... Quality Control Region: Region 1. 81.107Greenwood Intrastate Air Quality Control Region: Region 2....

  19. 40 CFR 81.88 - Billings Intrastate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Regions § 81.88 Billings Intrastate Air Quality Control Region. The Metropolitan Billings Intrastate Air Quality Control Region (Montana) has been renamed the Billings Intrastate Air Quality Control... to by Montana authorities as follows: Sec. 481.168Great Falls Intrastate Air Quality Control...

  20. Direct product quality control for energy efficient climate controlled transport of agro-material

    NARCIS (Netherlands)

    Verdijck, G.J.C.; Preisig, H.A.; Straten, van G.

    2005-01-01

    A (model-based) Product Quality Controller is presented for climate controlled operations involving agro-material, such as storage and transport. This controller belongs to the class of Model Predictive Controllers and fits in a previously developed hierarchical control structure. The new Product

  1. Design and implementation of the STKOS quality-control system

    Institute of Scientific and Technical Information of China (English)

    Haixia; SUN; Danya; LI; Junlian; LI; Sizhu; WU; Tiejun; HU; Qing; QIAN

    2015-01-01

    Purpose: The aim of this study is to develop and implement a quality-control system to ensure authority control of the different knowledge units for the Scientific & Technological Knowledge Organization Systems(STKOS).Design/methodology/approach: First, we analyzed quality-control requirements based on the construction of the STKOS Metathesaurus. Then we designed a quality-control framework, the task management and transfer mechanism, and a service model. Afterwards, we carried out the experiments to check the rules and algorithms used in the system. Finally, the system was developed, and gradually optimized during its service.Findings: The quality-control system supports collaborative knowledge construction, as well as consistency checks of knowledge units with different granularity levels, including terminologies, relationships, and concepts. The system can be flexibly configured.Research limitations: The system is oriented to an English-language knowledge organization system, and may not perform well with Chinese-language systems and ontologies.Practical implications: The system can be used to support the construction of a single knowledge organization system, as well as data warehousing and interoperable knowledge organization systems. Originality/value: The STKOS quality-control system not only focuses on content building for the knowledge system, but also supports collaborative task management.

  2. Controlled release fertilizer improves quality of container longleaf pine seedlings

    Science.gov (United States)

    R. Kasten Dumroese; Jeff Parkhurst; James P. Barnett

    2005-01-01

    In an operational trial, increasing the amount of nitrogen (N) applied to container longleaf pine seedlings by incorporating controlled release fertilizer (CRF) into the media improved seedling growth and quality. Compared with control seedlings that received 40 mg N, seedlings receiving 66 mg N through CRF supplemented with liquid fertilizer had needles that were 4 in...

  3. Quality control of systems of portal imaging; Control de calidad de sistemas de imagen portal

    Energy Technology Data Exchange (ETDEWEB)

    Olasolo Alonso, J.; Martin Albina, M. L.; Otal Palacin, A.; Fuentemilla Urio, N.; Miquelez Alonso, S.; Pellejero Pellejero, S.; Maneru Camara, F.; Lozares Cordero, S.; Rubio Arroniz, A.

    2013-07-01

    The importance of accuracy and reproducibility of the positioning of the patient for the radiotherapy treatment, makes key the image quality of the image device portal used for the verification of such positioning. the objective of this work is the implementation of a procedure of quality control that easily and quickly verify the main parameters of image quality of the EPID. (Author)

  4. Quality control in FISH as part of a laboratory's quality management system.

    Science.gov (United States)

    Hastings, Ros

    2010-01-01

    Quality control in the laboratory setting requires the establishment of a quality management system (QMS) that covers training, standard operating procedures, internal quality control, validation of tests, and external quality assessment (EQA). Laboratory accreditation through inspection by an external body is also desirable as this provides an effective procedure for assuring quality and also reassures the patient that the laboratory is working to acceptable international standards. The implementation of fluorescence in situ hybridisation (FISH) in the routine diagnostic laboratory requires rigorous quality control with attention to when it is appropriate to apply the technology, a systematic approach to the validation of probes, policies and procedures documenting the analytical validity of all FISH tests performed, technical procedures involved, and a comprehensive means of reporting results. Knowledge of the limitations of any FISH test is required in relation to the probe and/or tissue being examined, since errors of analysis and interpretation can result in incorrect patient management. A structured QMS with internal quality control and regular audits will minimise the error rate.

  5. Microscope-controlled glass bead blasting: a new technique

    Directory of Open Access Journals (Sweden)

    Peter Kotschy

    2011-01-01

    Full Text Available Peter Kotschy1, Sascha Virnik2, Doris Christ3, Alexander Gaggl21Private Practice, Vienna, Austria; 2Department of Oral and Maxillofacial Surgery, Central Hospital, Klagenfurt, Austria; 3Klagenfurt, AustriaObjective: The aim of periodontal therapy is the healing of periodontal inflammation; the protection of the attachment and the alveolar bone; and the regeneration of the periodontal structures. In the therapy of periodontitis, supra- and subgingival scaling and root planing plays a main role. The procedure described combines perfect root cleaning without scaling and root planing and minimal invasive periodontal surgery without a scalpel.Material and methods: Glass beads of 90 µm were used with the kinetic preparation unit PrepStart® under a pressure of 0.5–5 bar. This technique was practised only under visual control using the OPMI® PRO Magis microscope. Seven examinations were carried out at baseline after 3, 6, 12, 18, 24, and 36 months.Results: Time shows a statistically significant influence on all of the considered target variables (P < 0.0001 for all. As the according estimate is negative, probing depth decreases over time. The major decrease seems to be during the first 6 months. Considering probing depth, plaque on the main effect root shows significant influence (again, P < 0.0001 for all. Observations with high probing depth at the beginning were faster than those with low probing depth. The same characteristic appears by attachment level. Patients with more loss of attachment show more gain.Conclusions: Using microscope-controlled glass bead blasting results in a perfectly clean root surface using visual control (magnification 20×. Microscope-controlled glass bead blasting is therefore a good alternative to periodontal surgery.Keywords: periodontal therapy, microscope, periodontitis

  6. Adequate image quality with reduced radiation dose in prospectively triggered coronary CTA compared with retrospective techniques

    Energy Technology Data Exchange (ETDEWEB)

    Arnoldi, Elisabeth; Johnson, Thorsten R.; Rist, Carsten; Wintersperger, Bernd J.; Sommer, Wieland H.; Becker, Christoph R.; Reiser, Maximilian F.; Nikolaou, Konstantin [Ludwig-Maximilians University, Department of Clinical Radiology, University Hospitals Munich - Grosshadern Campus, Munich (Germany); Becker, Alexander [Ludwig-Maximilians University, Department of Medicine I, University Hospitals Munich - Grosshadern Campus, Munich (Germany)

    2009-09-15

    The goal of our study was to compare a prospective triggering (PT) CT technique with retrospectively gated (RG) CT techniques in coronary computed tomographic angiograms (CCTA) with respect to image quality and radiation dose. Sixty consecutive patients were enrolled. CCTAs using the RG technique were obtained with a dual-source 64-slice CT system in 40 patients, using ECG-triggered tube current modulation, with either a broad pulsing window at 30-80% of the RR interval (group RGb, 20 patients, heart rate > 70 bpm) or a small pulsing window at 70% (group RGs, 20 patients, heart rate < 70 bpm). The other 20 patients underwent CCTA using the PT technique on a 128-slice CT system (group PT, heart rate < 70 bpm). All images were evaluated by two observers for quality on a three-point scale, with 1 being excellent and 3 being insufficient. The effective radiation dose was calculated for each patient. The average image quality score was 1.5 {+-} 0.6 for PT, 1.35 {+-} 0.5 for RGs and 1.65 {+-} 0.5 for RGb. The mean effective dose for RGb was 9 {+-} 4 mSv, for RGs 7 {+-} 3 mSv and for PT 3 {+-} 1 mSv. This represents a 57% dose reduction for PT compared with RGs and a 67% dose reduction for PT compared with RGb. In conclusion, in selected patients CCTA with the PT technique offers adequate image quality with a significantly lower radiation dose compared with CCTA using RG techniques. (orig.)

  7. Application of Metabolomics to Quality Control of Natural Product Derived Medicines.

    Science.gov (United States)

    Lee, Kyung-Min; Jeon, Jun-Yeong; Lee, Byeong-Ju; Lee, Hwanhui; Choi, Hyung-Kyoon

    2017-06-14

    Metabolomics has been used as a powerful tool for the analysis and quality assessment of the natural product (NP)-derived medicines. It is increasingly being used in the quality control and standardization of NP-derived medicines because they are composed of hundreds of natural compounds. The most common techniques that are used in metabolomics consist of NMR, GC-MS, and LC-MS in combination with multivariate statistical analyses including principal components analysis (PCA) and partial least squares-discriminant analysis (PLS-DA). Currently, the quality control of the NP-derived medicines is usually conducted using HPLC and is specified by one or two indicators. To create a superior quality control framework and avoid adulterated drugs, it is necessary to be able to determine and establish standards based on multiple ingredients using metabolic profiling and fingerprinting. Therefore, the application of various analytical tools in the quality control of NP-derived medicines forms the major part of this review. Veregen(®) (Medigene AG, Planegg/Martinsried, Germany), which is the first botanical prescription drug approved by US Food and Drug Administration, is reviewed as an example that will hopefully provide future directions and perspectives on metabolomics technologies available for the quality control of NP-derived medicines.

  8. Model based control charts in stage 1 quality control

    NARCIS (Netherlands)

    A.J. Koning (Alex)

    1999-01-01

    textabstractIn this paper a general method of constructing control charts for preliminary analysis of individual observations is presented, which is based on recursive score residuals. A simulation study shows that certain implementations of these charts are highly effective in detecting assignable

  9. A Statistical Quality Control System in a Medium-Scale Weaving Mill: I. Control of Fabric Defects

    Directory of Open Access Journals (Sweden)

    Özlem DÜLGEROĞLU KISAOĞLU

    2010-03-01

    Full Text Available Establishing a control system in a medium-scale weaving mill by using statistical process control techniques was worked on and considered that the control system also would be a model for weaving mills. To determine production parameters and control them according to a definite sampling plan, the loom stoppages were investigated with their reasons and the defects on the fabric were detected during running of looms in process inspection. Therefore three different kinds of cord and a poplin fabric were observed. Analysis of loom-stoppages gives information about problems which are present in yarns, weaving preparation, weaving processes, and particularly indicates yarn quality, weaving machine adjustments and weaving preparation processes. In conclusion of woven fabric quality evaluations it was determined that the rate of defects originated from yarn is rather higher than that of defects originated from weaving preparation/weaving process.

  10. A Statistical Quality Control System in a Medium-Scale Weaving Mill: II. Control of Loom Stoppages

    Directory of Open Access Journals (Sweden)

    Özlem DÜLGEROĞLU KISAOĞLU

    2010-03-01

    Full Text Available Establishing a control system in a medium-scale weaving mill by using statistical process control techniques was worked on and considered that the control system also would be a model for weaving mills. To determine production parameters and control them according to a definite sampling plan, the loom stoppages were investigated with their reasons and the defects on the fabric were detected during running of looms in process inspection. Therefore three different kinds of cord and a poplin fabric were observed. Analysis of loom-stoppages gives information about problems which are present in yarns, weaving preparation, weaving processes, and particularly indicates yarn quality, weaving machine adjustments and weaving preparation processes. In conclusion of woven fabric quality evaluations it was determined that the rate of defects originated from yarn is rather higher than that of defects originated from weaving preparation/weaving process.

  11. A Randomized Controlled Trial of a Novel Self-Help Technique for Impulse Control Disorders: A Study on Nail-Biting

    Science.gov (United States)

    Moritz, Steffen; Treszl, Andras; Rufer, Michael

    2011-01-01

    Nail-biting is currently classified as an impulse control disorder not otherwise specified. Although seldom targeted as a primary symptom, nail-biting is often associated with somatic complications and decreased quality of life. The present study assessed the effectiveness of an innovative self-help technique, titled decoupling (DC). DC aims at…

  12. Quality guaranteed aggregation based model predictive control and stability analysis

    Institute of Scientific and Technical Information of China (English)

    LI DeWei; XI YuGeng

    2009-01-01

    The input aggregation strategy can reduce the online computational burden of the model predictive controller. But generally aggregation based MPC controller may lead to poor control quality. Therefore, a new concept, equivalent aggregation, is proposed to guarantee the control quality of aggregation based MPC. From the general framework of input linear aggregation, the design methods of equivalent aggregation are developed for unconstrained and terminal zero constrained MPC, which guarantee the actual control inputs exactly to be equal to that of the original MPC. For constrained MPC, quasi-equivalent aggregation strategies are also discussed, aiming to make the difference between the control inputs of aggregation based MPC and original MPC as small as possible. The stability conditions are given for the quasi-equivalent aggregation based MPC as well.

  13. Computer Assisted Audit Techniques and Audit Quality in Developing Countries: Evidence from Nigeria

    Directory of Open Access Journals (Sweden)

    Omonuk JB

    2015-12-01

    Full Text Available Most business organizations world-over have computerized their accounting systems. Extant literature finds that the use of Computer Assisted Audit Techniques (CAATs is positively related to the quality of audit reports. CAATs are widely applied to audit financial statements in developed countries. However, there is a void in literature about the audit of computerized accounts in developing countries. We draw a sample from Nigeria to investigate the following questions, “Do auditors effectively audit computerized accounts and; Is there a positive relationship between the use of CAATs and audit quality?” Using descriptive statistics, correlation analysis and logistic multiple regression, we provide evidence that: (1 CAATs are effectively used, (2 there is a positive relationship between the use of CAATS and audit quality, and (3 in a sample that excludes the big 4 International audit firms, local Nigerian firms are not effective in applying CAATs, and so, do not produce quality audit reports.

  14. The impact of quality control in RNA-seq experiments

    Science.gov (United States)

    Merino, Gabriela A.; Fresno, Cristóbal; Netto, Frederico; Dias Netto, Emmanuel; Pratto, Laura; Fernández, Elmer A.

    2016-04-01

    High throughput mRNA sample sequencing, known as RNA-seq, is as a powerful approach to detect differentially expressed genes starting from millions of short sequence reads. Although several workflows have been proposed to analyze RNA-seq data, the experiment quality control as a whole is not usually considered, thus potentially biasing the results and/or causing information lost. Experiment quality control refers to the analysis of the experiment as a whole, prior to any analysis. It not only inspects the presence of technical effects, but also if general biological assumptions are fulfilled. In this sense, multivariate approaches are crucial for this task. Here, a multivariate approach for quality control in RNA-seq experiments is proposed. This approach uses simple and yet effective well-known statistical methodologies. In particular, Principal Component Analysis was successfully applied over real data to detect and remove outlier samples. In addition, traditional multivariate exploration tools were applied in order to asses several controls that can help to ensure the results quality. Based on differential expression and functional enrichment analysis, here is demonstrated that the information retrieval is significantly enhanced through experiment quality control. Results show that the proposed multivariate approach increases the information obtained from RNA-seq data after outlier samples removal.

  15. Controlled shear filtration: A novel technique for animal cell separation.

    Science.gov (United States)

    Vogel, J H; Kroner, K H

    1999-06-20

    A novel rotary microfiltration technique specifically suited for the separation of animal cells has been developed. The concept allows the independent adjustment of wall shear stress, transmembrane pressure, and residence time, allowing straightforward optimization of the microfiltration process. By using a smooth, conically shaped rotor, it is possible to establish a controlled shear field in which animal cells experience a significant hydrodynamic lift away from the membrane surface. It is shown in preliminary experiments that shear-induced cell-rupture speeds up membrane clogging and that cell debris poses the most significant problem in harvesting of BHK cell cultures by dynamic microfiltration. However, a threshold value of shear stability exists which depends on the frequency of passing the shear field, the residence time in the shear field, as well as on cell status. By operating close to this threshold value, cell viability can be maintained while concentration polarization is efficiently minimized. By applying this concept, it is possible to attain flux rates several times higher compared to conventional crossflow filtration. Controlled shear filtration (CSF) can be used for batch harvesting as well as for cell retention in high cell density systems. In batch harvesting of hIL-2 from rBHK cell culture, a constant flux rate of 290 L h-1 m-2 has been adjusted without indication of membrane clogging or fouling.

  16. Mitigation of Power Quality problems by UPQC for Renewable Energy Resources using Fuzzy Logic Technique

    Directory of Open Access Journals (Sweden)

    Phaneendra Venkat Gatta

    2014-05-01

    Full Text Available The wind energy conversion system Wind Farms (WF are employ squirrel cage induction generator (SCIG. The injection of wind power into an electric grid causes the power quality problems such as variation of voltage, flicker, harmonics etc, and these are measured according to national/international guidelines. To solve these problems Custom Power Devices (CUPS are used. This paper has proposed a compensation strategy based on a particular cups device for Unified Power Quality Compensator (UPQC with an application of PI and Fuzzy Logic Controllers. The proposed strategy controls both active and reactive power in the converters of UPQC. This paper presents the comparison between without UPQC, UPQC with PI controller and UPQC with Fuzzy Logic Controller. By using MATLAB/SIMULINK software the control strategies are designed. The simulation results are shown for comparison of different control strategies and by performing FFT analysis Total Harmonic Distortions (THD are calculated.

  17. Flight control design using a blend of modern nonlinear adaptive and robust techniques

    Science.gov (United States)

    Yang, Xiaolong

    In this dissertation, the modern control techniques of feedback linearization, mu synthesis, and neural network based adaptation are used to design novel control laws for two specific applications: F/A-18 flight control and reusable launch vehicle (an X-33 derivative) entry guidance. For both applications, the performance of the controllers is assessed. As a part of a NASA Dryden program to develop and flight test experimental controllers for an F/A-18 aircraft, a novel method of combining mu synthesis and feedback linearization is developed to design longitudinal and lateral-directional controllers. First of all, the open-loop and closed-loop dynamics of F/A-18 are investigated. The production F/A-18 controller as well as the control distribution mechanism are studied. The open-loop and closed-loop handling qualities of the F/A-18 are evaluated using low order transfer functions. Based on this information, a blend of robust mu synthesis and feedback linearization is used to design controllers for a low dynamic pressure envelope of flight conditions. For both the longitudinal and the lateral-directional axes, a robust linear controller is designed for a trim point in the center of the envelope. Then by including terms to cancel kinematic nonlinearities and variations in the aerodynamic forces and moments over the flight envelope, a complete nonlinear controller is developed. In addition, to compensate for the model uncertainty, linearization error and variations between operating points, neural network based adaptation is added to the designed longitudinal controller. The nonlinear simulations, robustness and handling qualities analysis indicate that the performance is similar to or better than that for the production F/A-18 controllers. When the dynamic pressure is very low, the performance of both the experimental and the production flight controllers is degraded, but Level I handling qualities are still achieved. A new generation of Reusable Launch Vehicles

  18. A simulation benchmark to evaluate the performance of advanced control techniques in biological wastewater treatment plants

    Directory of Open Access Journals (Sweden)

    Sotomayor O.A.Z.

    2001-01-01

    Full Text Available Wastewater treatment plants (WWTP are complex systems that incorporate a large number of biological, physicochemical and biochemical processes. They are large and nonlinear systems subject to great disturbances in incoming loads. The primary goal of a WWTP is to reduce pollutants and the second goal is disturbance rejection, in order to obtain good effluent quality. Modeling and computer simulations are key tools in the achievement of these two goals. They are essential to describe, predict and control the complicated interactions of the processes. Numerous control techniques (algorithms and control strategies (structures have been suggested to regulate WWTP; however, it is difficult to make a discerning performance evaluation due to the nonuniformity of the simulated plants used. The main objective of this paper is to present a benchmark of an entire biological wastewater treatment plant in order to evaluate, through simulations, different control techniques. This benchmark plays the role of an activated sludge process used for removal of organic matter and nitrogen from domestic effluents. The development of this simulator is based on models widely accepted by the international community and is implemented in Matlab/Simulink (The MathWorks, Inc. platform. The benchmark considers plant layout and the effects of influent characteristics. It also includes a test protocol for analyzing the open and closed-loop responses of the plant. Examples of control applications in the benchmark are implemented employing conventional PI controllers. The following common control strategies are tested: dissolved oxygen (DO concentration-based control, respirometry-based control and nitrate concentration-based control.

  19. 75 FR 80066 - Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed Information...

    Science.gov (United States)

    2010-12-21

    ... URBAN DEVELOPMENT Quality Control Requirements for Direct Endorsement Lenders; Notice of Proposed.... This Notice also lists the following information: Title of Proposal: Quality Control Requirements for... lenders, since these institutions must also conduct quality control on all loans they originate...

  20. Secondary Control for Voltage Quality Enhancement in Microgrids

    DEFF Research Database (Denmark)

    Savaghebi, Mehdi; Jalilian, Alireza; Vasquez, Juan Carlos

    2012-01-01

    In this paper, a hierarchical control scheme is proposed for enhancement of sensitive load bus (SLB) voltage quality in microgrids. The control structure consists of primary and secondary levels. The primary control level comprises distributed generators (DGs) local controllers. Each...... of these controllers includes a selective virtual impedance loop which is considered to improve sharing of fundamental and harmonic components of load current among the DG units. The sharing improvement is provided at the expense of increasing voltage unbalance and harmonic distortion. Thus, the secondary control...... level is applied to manage the compensation of SLB voltage unbalance and harmonics by sending proper control signals to the primary level. DGs compensation efforts are controlled locally at the primary level. The system design procedure for selecting proper control parameters is discussed. Simulation...