WorldWideScience

Sample records for quality control system

  1. INFORMATION SYSTEM QUALITY CONTROL KNOWLEDGE

    Directory of Open Access Journals (Sweden)

    Vladimir Nikolaevich Babeshko

    2017-02-01

    Full Text Available The development of the educational system is associated with the need to control the quality of educational services. Quality control knowledge is an important part of the scientific process. The penetration of computers into all areas of activities changing approaches and technologies that previously they were used.

  2. Expert database system for quality control

    Science.gov (United States)

    Wang, Anne J.; Li, Zhi-Cheng

    1993-09-01

    There are more competitors today. Markets are not homogeneous they are fragmented into increasingly focused niches requiring greater flexibility in the product mix shorter manufacturing production runs and above allhigher quality. In this paper the author identified a real-time expert system as a way to improve plantwide quality management. The quality control expert database system (QCEDS) by integrating knowledge of experts in operations quality management and computer systems use all information relevant to quality managementfacts as well as rulesto determine if a product meets quality standards. Keywords: expert system quality control data base

  3. Quality control of mammographic systems

    International Nuclear Information System (INIS)

    Espana Lopez, M. L.

    2001-01-01

    High quality in mammography is a difficult objective to achieve, that is the reason for what efforts are made in order to improve equipment, to offer good combinations screen-film, and professional staff dedicated to this technique [es

  4. Quality control of gamma radiation measuring systems

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The problem of quality control and assurance of gamma radiation measuring systems has been described in detail. The factors deciding of high quality of radiometric measurements as well as statistical testing and calibration of measuring systems have been presented and discussed

  5. Water quality control system and water quality control method

    International Nuclear Information System (INIS)

    Itsumi, Sachio; Ichikawa, Nagayoshi; Uruma, Hiroshi; Yamada, Kazuya; Seki, Shuji

    1998-01-01

    In the water quality control system of the present invention, portions in contact with water comprise a metal material having a controlled content of iron or chromium, and the chromium content on the surface is increased than that of mother material in a state where compression stresses remain on the surface by mechanical polishing to form an uniform corrosion resistant coating film. In addition, equipments and/or pipelines to which a material controlling corrosion potential stably is applied on the surface are used. There are disposed a cleaning device made of a material less forming impurities, and detecting intrusion of impurities and removing them selectively depending on chemical species and/or a cleaning device for recovering drain from various kinds of equipment to feedwater, connecting a feedwater pipeline and a condensate pipeline and removing impurities and corrosion products. Then, water can be kept to neutral purified water, and the concentrations of oxygen and hydrogen in water are controlled within an optimum range to suppress occurrence of corrosion products. (N.H.)

  6. TRAINING SYSTEM OF FUTURE SPECIALISTS: QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    Vladimir A. Romanov

    2015-01-01

    Full Text Available The aim of the investigation is development of innovative strategy of quality control training of engineers and skilled workers (hereinafter – future specialists in educational professional organizations on the principles of social partnership.Methods. Theoretic: theoretic and methodological analysis, polytheoretic synthesis, modeling. Empirical: research and generalization of the system, process and competence – based approaches experience, experiment, observation, surveys, expert evaluation, SWOT-analysis as a method of strategic planning which is to identify the internal and external factors (socio-cultural of the organization surrounding.Results. The strategy of the development of the process of quality control training in educational professional organizations and a predictive model of the system of quality control training for future engineers and workers have been created on the analysis and synthesis of a quantitative specification of the quality, the obtained experience and success in control training of future specialists in educational professional organizations in recent economic and educational conditions.Scientific novelty. There has been built a predicative model of quality control training of future specialists to meet modern standards and the principles of social partnership; the control algorithm of the learning process, developed in accordance with the standards (international of quality ISO in the implementation of the quality control systems of the process approach (matrix-based responsibility, competence and remit of those responsible for the education process in the educational organization, the «problem» terms and diagnostic tools for assessing the quality of professional training of future specialists. The perspective directions of innovation in the control of the quality of future professionals training have been determined; the parameters of a comprehensive analysis of the state of the system to ensure the

  7. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  8. [Compatibility of different quality control systems].

    Science.gov (United States)

    Invernizzi, Enrico

    2002-01-01

    Management of the good laboratory practice (GLP) quality system presupposes its linking to a basic recognized and approved quality system, from which it can draw on management procedures common to all quality systems, such as the ISO 9000 set of norms. A quality system organized in this way can also be integrated with other dedicated quality systems, or parts of them, to obtain principles or management procedures for specific topics. The aim of this organization is to set up a reliable, recognized quality system compatible with the principles of GLP and other quality management systems, which provides users with a simplified set of easily accessible management tools and answers. The organization of this quality system is set out in the quality assurance programme, which is actually the document in which the test facility incorporates the GLP principles into its own quality organization.

  9. Technical quality control - constancy controls for digital mammography systems

    International Nuclear Information System (INIS)

    Pedersen, K.; Landmark, I.D.; Bredholt, K.; Hauge, I.H.R.

    2009-04-01

    To ensure the quality of mammographic images, so-called constancy control tests are performed frequently. The report contains a programme for constancy control of digital mammography systems, encompassing the mammography unit, computed radiography (CR) systems, viewing conditions and displays, printers, and procedures for data collection for patient dose calculations. (Author)

  10. 14 CFR 145.211 - Quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Quality control system. 145.211 Section 145...) SCHOOLS AND OTHER CERTIFICATED AGENCIES REPAIR STATIONS Operating Rules § 145.211 Quality control system. (a) A certificated repair station must establish and maintain a quality control system acceptable to...

  11. 14 CFR 21.147 - Changes in quality control system.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Changes in quality control system. 21.147 Section 21.147 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION... quality control system. After the issue of a production certificate, each change to the quality control...

  12. Fuel element radiometry system for quality control

    International Nuclear Information System (INIS)

    Bhattacharya, Sadhana; Gaur, Swati; Sridhar, Padmini; Mukhopadhyay, P.K.; Vaidya, P.R.; Das, Sanjoy; Sinha, A.K.; Bhatt, Sameer

    2010-01-01

    An indigenous and fully automatic PC based radiometry system has been designed and developed. The system required a vibration free scanning with various automated sequential movements to scan the fuel pin of size 5.8 mm (OD) x 1055 mm (L) along its full length. A mechanical system with these requirements and precision controls has been designed. The system consists of a tightly coupled and collimated radiation source-detector unit and data acquisition and control system. It supports PLC based control electronics to control and monitor the movement of fuel element, nuclear data acquisition and analysis system and feedback system to the mechanical scanner to physically accept or reject the fuel pin based on the decision derived by the software algorithms. (author)

  13. Quality control system response to stochastic growth of amyloid fibrils

    DEFF Research Database (Denmark)

    Pigolotti, S.; Lizana, L.; Sneppen, K.

    2013-01-01

    We introduce a stochastic model describing aggregation of misfolded proteins and degradation by the protein quality control system in a single cell. Aggregate growth is contrasted by the cell quality control system, that attacks them at different stages of the growth process, with an efficiency...... that decreases with their size. Model parameters are estimated from experimental data. Two qualitatively different behaviors emerge: a homeostatic state, where the quality control system is stable and aggregates of large sizes are not formed, and an oscillatory state, where the quality control system...

  14. Production control system specified quality sausage products

    Directory of Open Access Journals (Sweden)

    A. V. Tokarev

    2016-01-01

    Full Text Available The problem of management of production target in technological system of production of sausages of the set quality is considered in article. Decomposition of technological system is considered. Functions of management are allocated: formation of an optimum compounding of forcemeat, expert analysis of a compounding, laboratory analysis of a compounding and its statement. Information technology of interaction of these functions is offered. The mathematical problem definition of finding of an optimum compounding meat product with use of possible substitutes of ingredients is presented. This mathematical problem is a classical linear programming problem whose solution has the standard program. Since the manufacture of the finished product are various nonlinear effects are taken into account at the present time it is practically impossible, the methodology provided in this operation "Expert analysis of the formulation" and "Laboratory analysis of the finished product." An example of calculating the optimum alternative base recipe "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. For an alternative formulation demands were made at a cost of meat, the ingredient composition, as well as the final product organoleptic and physic-chemical indicators should comply with regulatory requirements "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002. Indicator acid activity (pH calculated stuffing formulation should be in the range 6.0-6.3. As a partial replacement for the main raw material have been proposed acceptable substitutes. It was necessary to calculate on the basis of the formulation "Sausages “Viennese with cheese”" TS 9213-010-40155161-2002 optimal price and quality alternative formulation. As a result of depreciation of the value of alternative stuffing recipe was 14,5 % when all of the restrictions on the consumer properties. The proposed information technology implemented in the software package "Multi

  15. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  16. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  17. AUTOMATION OF THE SYSTEM OF INTERNAL LABORATORY QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    V. Z. Stetsyuk

    2015-05-01

    Full Text Available Quality control system base d on the principles of standardi zation of all phases of laboratory testing and analysis of internal laboratory quality control and external quality assessment. For the detection accuracy of the results of laboratory tests, carried out internally between the laboratory and laboratory quality control. Under internal laboratory quality control we understand measurement results of each analysis in each anal ytical series rendered directly in the lab every day. The purpose of internal laboratory control - identifying and eliminating unacceptable deviations from standard perfor mance test in the laboratory, i.e. identifying and eliminating harmful analytical errors. The solutions to these problems by implementing automated systems - software that allows you to optimize analytical laboratory research stage of the procedure by automatically creating process control charts was shown.

  18. [Evaluation of the quality control system in blood transfusion service].

    Science.gov (United States)

    Jovanović, R

    2000-01-01

    Implementation of quality system improvement at the Blood Transfusion Institute Novi Sad, included adjustments in practice to the request of ISO 9001 standard. Quality improvement must be a permanent activity of the Institute. The audit is a management tool for monitoring the quality assurance system and is either a quality audit or a medical audit. A well planned, comprehensive quality audit covers each activity of the Blood Transfusion Institute. The procedures may be internal or external. Quality manager is responsible for annual internal quality audits. The purpose of internal audits is to check the efficiency of the quality system in terms of realization of quality policy, fulfullment of designed targets and implementation of quality system documents. An internal quality audit is performed in accordance with the procedure and audit findings are reported to the management in a form of internal quality report as a part of quality system review. The findings must be communicated to all persons responsible for the controlled area. Quality manager can initiate an internal quality audit whenever it is realized that problems about the quality system have occurred. Audits are conducted by the quality manager or an audit team. The accurate list of internal auditors is kept in the Institute archive. Medical audit carried out by a transfusion committee, evaluates the quality of blood transfusion for determining the degree of compliance with established local or national guidelines, in order to promote optimal transfusion practice. Audits are not only used for determining further quality management activities, but also make basis for creating and maintenance of excellent relations with product and service users. Considering all this, Blood Transfusion Institute exceeds the requirements of ISO 9000 standards series.

  19. Modern control system of quality of services of public catering

    Directory of Open Access Journals (Sweden)

    Lavrova Larisa Jur'evna

    2015-12-01

    Full Text Available The modern control system of quality of services of public catering as the instrument of management of safety is effective and legitimate. In article changes in requirements of normative documents are considered. Interdisciplinary mechanisms of implementation of requirements of normative documents are described. Uniform approaches between marketing and quality management regarding monitoring of satisfaction of consumers are determined. Results of researches of the organization of collection of information about degree of satisfaction of consumers are described. Knowledge, necessary for the staff of catering establishments, and skills regarding development, introduction and maintenance of quality management system in activity of the enterprises of food are established.

  20. HACCP system for quality control of food irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Yiming, Ha [The Institute of Application of Atomic Energy, CAAS, Beijing (China)

    2004-02-01

    This paper introduces the Hazard Analysis and Critical Control Point System (HACCP) and analyses all hazard factors which would possibly affect the product quality in processing of irradiation dehydrated vegetables. It suggests that the irradiation food factories in China should set up HACCP as soon as possible and discusses the ways to set up HACCP.

  1. HACCP system for quality control of food irradiation

    International Nuclear Information System (INIS)

    Ha Yiming

    2004-01-01

    This paper introduces the Hazard Analysis and Critical Control Point System (HACCP) and analyses all hazard factors which would possibly affect the product quality in processing of irradiation dehydrated vegetables. It suggests that the irradiation food factories in China should set up HACCP as soon as possible and discusses the ways to set up HACCP

  2. Integrated evolutionary computation neural network quality controller for automated systems

    Energy Technology Data Exchange (ETDEWEB)

    Patro, S.; Kolarik, W.J. [Texas Tech Univ., Lubbock, TX (United States). Dept. of Industrial Engineering

    1999-06-01

    With increasing competition in the global market, more and more stringent quality standards and specifications are being demands at lower costs. Manufacturing applications of computing power are becoming more common. The application of neural networks to identification and control of dynamic processes has been discussed. The limitations of using neural networks for control purposes has been pointed out and a different technique, evolutionary computation, has been discussed. The results of identifying and controlling an unstable, dynamic process using evolutionary computation methods has been presented. A framework for an integrated system, using both neural networks and evolutionary computation, has been proposed to identify the process and then control the product quality, in a dynamic, multivariable system, in real-time.

  3. High quality flux control system for electron gun evaporation

    International Nuclear Information System (INIS)

    Appelbloom, A.M.; Hadley, P.; van der Marel, D.; Mooij, J.E.

    1991-01-01

    This paper reports on a high quality flux control system for electron gun evaporation developed and tested for the MBE growth of high temperature superconductors. The system can be applied to any electron gun without altering the electron gun itself. Essential elements of the system are a high bandwidth mass spectrometer, control electronics and a high voltage modulator to sweep the electron beam over the melt at high frequencies. the sweep amplitude of the electron beam is used to control the evaporation flux at high frequencies. The feedback loop of the system has a bandwidth of over 100 Hz, which makes it possible to grow superlattices and layered structures in a fast and precisely controlled manner

  4. Water quality control device and water quality control method for reactor primary coolant system

    International Nuclear Information System (INIS)

    Wada, Yoichi; Ibe, Eishi; Watanabe, Atsushi.

    1995-01-01

    The present invention is suitable for preventing defects due to corrosion of structural materials in a primary coolant system of a BWR type reactor. Namely, a concentration measuring means measures the concentration of oxidative ingredients contained in a reactor water. A reducing electrode is disposed along a reactor water flow channel in the primary coolant system and reduces the oxidative ingredients. A reducing counter electrode is disposed along the reactor water flow channel in the primary coolant system, and electrically connected to the reducing electrode. The reactor structural materials are used as a reference electrode providing a reference potential to the reducing electrode and the reducing counter electrode. A potential control means controls the potential of the reducing electrode relative to the reference potential based on the signals from the concentration measuring means. A stable reference potential in a region where an effective oxygen concentration is stable can be obtained irrespective of the change of operation conditions by using the reactor structural materials disposed to a boiling region in the reactor core as a reference electrode. As a result, the water quality can be controlled at high accuracy. (I.S.)

  5. Quality control of MC and A system and integrated safeguards

    International Nuclear Information System (INIS)

    Osabe, Takeshi

    2000-01-01

    In the integrated safeguards regime, co-operation with SSAC is a vital element to achieve efficiency of safeguards implementation while maintaining the effectiveness. However, the degree of co-operation fully depends upon the credibility, technical capability and the transparency of SSAC. Since the credibility of SSAC (States' System of Accounting for and Control of Nuclear Materials) depends heavily on effectiveness of facility operator's Material Control and Accounting (MC and A) practice, some measures to provide continuous assurance of the function and effectiveness of the system such as quality assurance program including periodical system audit (diagnostic) function ought to be established. This paper discusses quality assurance program for facility level MC and A including audit (diagnostic) method to maintain continuous assurance of the effectiveness. (author)

  6. Quality control procedures of dental diagnostic radiology systems

    International Nuclear Information System (INIS)

    Andrade, Paula Serra Sasaki

    2007-01-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  7. Quality control in PET systems employing 2-D modular detectors

    International Nuclear Information System (INIS)

    Daghighian, F.; Hoffman, E.J.; Huang, S.C.

    1989-01-01

    Many new PET scanner designs employ 2-D detector modules to cost effectively achieve higher image and axial resolution. These systems are potentially less stable than older designs and the loss of a single photomultiplier can disable a large section of a multislice PET system. Because of these factors, it is now necessary to develop more sophisticated quality control procedures that are designed to detect problems as early as possible. The authors have developed and put into operation three automated quality control procedure that are designed to detect problems quickly with a minimum effort on the part of the user. These tests check: (1) stability of the detector modules in terms of efficiency, (2) resolution and its uniformity, (3) the reproducibility of the data

  8. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; Shappert, L.B.

    1992-01-01

    This paper discusses applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 which are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  9. Quality assurance in a cask fleet parts control system

    International Nuclear Information System (INIS)

    Fernandez, C.; McCreery, P.N.; Shappert, L.B.

    1991-01-01

    Applicable portions of the eighteen Quality Assurance criteria of Subpart H, 10 CFR 71 are incorporated into a relational data base system which has been designed to manage the spare parts control system for a fleet of spent nuclear fuel casks. The system includes not only parts in warehouse storage but parts in use in the field plus casks, ancillary equipment, test equipment, support devices, and even personnel. It provides a high degree of assurance that any device for which a condition for certification has expired will be flagged for recertification testing or removal from service well before the critical date

  10. CASE STUDY ON WATER QUALITY CONTROL IN AN AQUAPONIC SYSTEM

    Directory of Open Access Journals (Sweden)

    Radu Mihai Filep

    2016-07-01

    Full Text Available Aquaponic systems are integrated systems that combine fish farming and different types of plants. It involves a dynamic interaction between fish plants and bacteria. Fish and plants are dependent the equilibrium of dissolved nutrients and water quality. Only by striking a balance between dissolved nutrients and water quality we can achieve a large production of plants and healthy fish. Thus, control of water quality in an aquaponic system is essential in order to obtain performance in raising fish and plants. The experiment was conducted in the laboratory of Fisheries and Aquaculture of the Faculty of Animal Science of the University of Agronomic Sciences and Veterinary Medicine of Bucharest within a period of 30 days. The system used for the experiment was designed and developed in the laboratory mentioned above. The plant used for water treatment in the system was basil (Ocimum basilicum. Fish species grown in the system was culture carp (Cyprinus carpio. Indicators measured to assess water quality in the system were: temperature, pH, dissolved oxygen, total ammonia, nitrites, nitrates and phosphates. The values determined pH 7.4-7.6, dissolved oxygen 8-10 mg / l, NH4 0.05-05 mg/ l, NO2 0.1-3.2 mg / l, NO3 0-80 mg / l, 0.02-0.3 mg, PO4 0.02-0.3 mg/l were not too high. In conclusion it was demonstrated that water quality in the aquaponic system studied is propitious to the growth and welfare of fish the registered values are not to be harmful.

  11. Six Sigma Quality Management System and Design of Risk-based Statistical Quality Control.

    Science.gov (United States)

    Westgard, James O; Westgard, Sten A

    2017-03-01

    Six sigma concepts provide a quality management system (QMS) with many useful tools for managing quality in medical laboratories. This Six Sigma QMS is driven by the quality required for the intended use of a test. The most useful form for this quality requirement is the allowable total error. Calculation of a sigma-metric provides the best predictor of risk for an analytical examination process, as well as a design parameter for selecting the statistical quality control (SQC) procedure necessary to detect medically important errors. Simple point estimates of sigma at medical decision concentrations are sufficient for laboratory applications. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Ensuring Control Processes Quality in Relay System Without Speed Sensor

    Directory of Open Access Journals (Sweden)

    R. P. Simonyants

    2014-01-01

    Full Text Available The paper considers topical issues of constructing relay systems to control spacecraft attitude and stabilization with no speed sensors (SS owing to use of internal feedback (IF. To research this system by point methods, e.g. a point mapping method, is difficult because of the need to solve the transcendent equations containing parameters both of control object and of IF. We propose the “diagram of superimpositions" (DS method based on topological transformations of the phase space and introduction of a relative time, which enables us to solve engineering problems in analysis and synthesis effectively.The concept of the method is based on the assertion that there is an unambiguous dependence between quality of dynamical regimes in the control system and characteristics of IF transition function. To justify the method a simplified mathematical model of spacecraft motion is applied. The following conditions are accepted: perturbations can be neglected; when the control function is activated, the signal of IF is equal to zero. To the phase surfaces are applied topological symmetry transformations, alignment and projection onto the plane with one of its coordinates being the relative time.The paper gives specific examples of systems with aperiodic feedback (AF for two versions of parameters to satisfy the requirements: I – in quality of self-oscillation mode (by pulse width in the limit cycle; II – in quality of transition process (lack of sliding modes. It is shown that the requirements II and I are contradictory for the system with AF while the sliding modes are unacceptable.It is shown that DS can be used to synthesize the IF to meet requirements of both steady and transient processes consistently. Using the IF it is possible to implement the shutdown laws of the control action on the DS without SS, the same as in case of using the SS. It is shown that in sliding modes transient processes poor in quality can be completely eliminated by

  13. TL dosimetry for quality control of CR mammography imaging systems

    Science.gov (United States)

    Gaona, E.; Nieto, J. A.; Góngora, J. A. I. D.; Arreola, M.; Enríquez, J. G. F.

    The aim of this work is to estimate the average glandular dose with thermoluminescent (TL) dosimetry and comparison with quality imaging in computed radiography (CR) mammography. For a measuring dose, the Food and Drug Administration (FDA) and the American College of Radiology (ACR) use a phantom, so that dose and image quality are assessed with the same test object. The mammography is a radiological image to visualize early biological manifestations of breast cancer. Digital systems have two types of image-capturing devices, full field digital mammography (FFDM) and CR mammography. In Mexico, there are several CR mammography systems in clinical use, but only one system has been approved for use by the FDA. Mammography CR uses a photostimulable phosphor detector (PSP) system. Most CR plates are made of 85% BaFBr and 15% BaFI doped with europium (Eu) commonly called barium flourohalideE We carry out an exploratory survey of six CR mammography units from three different manufacturers and six dedicated X-ray mammography units with fully automatic exposure. The results show three CR mammography units (50%) have a dose greater than 3.0 mGy without demonstrating improved image quality. The differences between doses averages from TLD system and dosimeter with ionization chamber are less than 10%. TLD system is a good option for average glandular dose measurement for X-rays with a HVL (0.35-0.38 mmAl) and kVp (24-26) used in quality control procedures with ACR Mammography Accreditation Phantom.

  14. Quality Control of Mega Voltage Portal Imaging System

    International Nuclear Information System (INIS)

    Diklic, A.; Dundara Debeljuh, D.; Jurkovic, S.; Smilovic Radojcic, D.; Svabic Kolacio; Kasabasic, M.; Faj, D.

    2013-01-01

    The Electronic Portal Imaging Device (EPID) is a system used to verify either the correct positioning of the patient during radiotherapy treatment or the linear accelerator beam parameters. The correct position of the patient corresponds to the position at which the patient was scanned at the CT simulator and according to which the therapy plan was made and optimized. Regarding this, besides the advanced treatment planning system and optimized treatment planning techniques, the day-to-day reproduction of simulated conditions is of great importance for the treatment outcome. Therefore, to verify the patient set-up portal imaging should be applied prior to the first treatment session and repeated according to treatment prescriptions during the treatment. In order to achieve full functionality and precision of the EPID, it must be included in radiotherapy Quality Control (QC) programme. The QC of the Mega Voltage portal imaging system was separated in two parts. In the first, the QC of the detector parameters should be performed. For this purpose, the FC2 and QC3 phantoms should be used, along with the Portal Image Processing System program (PIPSpro) package for data analysis. The second part of the QC of the linear accelerator's portal imaging system should include the QC of the CBCT. In this part a set of predefined manufacturer's tests using two different phantoms, one for the geometry calibration and the other for the image quality evaluation, should be performed. Also, the treatment conditions should be simulated using anthropomorphic phantoms and dose distributions for particular EPID protocols should be measured. Procedures for quality control of the portal imaging system developed and implemented at University Hospital Rijeka are presented in this paper.(author)

  15. Software application for quality control protocol of mammography systems

    International Nuclear Information System (INIS)

    Kjosevski, Vladimir; Gershan, Vesna; Ginovska, Margarita; Spasevska, Hristina

    2010-01-01

    Considering the fact that the Quality Control of the technological process of the mammographic system involves testing of a large number of parameters, it is clearly evident that there is a need for using the information technology for gathering, processing and storing of all the parameters that are result of this process. The main goal of this software application is facilitation and automation of the gathering, processing, storing and presenting process of the data related to the qualification of the physical and technical parameters during the quality control of the technological process of the mammographic system. The software application along with its user interface and database has been made with the Microsoft Access 2003 application which is part of the Microsoft Office 2003 software packet and has been chosen as a platform for developing because it is the most commonly used office application today among the computer users in the country. This is important because it will provide the end users a familiar environment to work in, without the need for additional training and improving the computer skills that they posses. Most importantly, the software application is easy to use, fast in calculating the parameters needed and it is an excellent way to store and display the results. There is a possibility for up scaling this software solution so it can be used by many different users at the same time over the Internet. It is highly recommended that this system is implemented as soon as possible in the quality control process of the mammographic systems due to its many advantages.(Author)

  16. Development of quality control system for fingerprint comparison processes

    Directory of Open Access Journals (Sweden)

    Shiquan Liu

    2017-01-01

    Full Text Available Fingerprint evidence played an important role in investigation, prosecution, and trial process due to the belief of its uniqueness and unchanged characteristics. However, in recent years, the science behind the process of fingerprint comparisons has been questioned. Main research questions have been focusing on the opaqueness within the comparison processes, subjective judgments, lack of universal standards, no error rate expression on final conclusions, and poor scientific fundamental research data. Facing the above-mentioned questions, this paper aims to suggest a quality control system (QCS for fingerprint comparison processes. This QCS is based on the use of software (PiAnoS and its technological features, being able to provide a data management model to increase the transparency and quality of fingerprint comparison processes.

  17. A quality control atlas for scintillation camera systems

    International Nuclear Information System (INIS)

    Busemann Sokole, E.; Graham, L.S.; Todd-Pokropek, A.; Wegst, A.; Robilotta, C.C.

    2002-01-01

    Full text: The accurate interpretation of quality control and clinical nuclear medicine image data is coupled to an understanding of image patterns and quantitative results. Understanding is gained by learning from different examples, and knowledge of underlying principles of image production. An Atlas of examples has been created to assist with interpreting quality control tests and recognizing artifacts in clinical examples. The project was initiated and supported by the International Atomic Energy Agency (IAEA). The Atlas was developed and written by Busemann Sokole from image examples submitted from nuclear medicine users from around the world. The descriptive text was written in a consistent format to accompany each image or image set. Each example in the atlas finally consisted of the images; a brief description of the data acquisition, radionuclide/radiopharmaceutical, specific circumstances under which the image was produced; results describing the images and subsequent conclusions; comments, where appropriate, giving guidelines for follow-up strategies and trouble shooting; and occasional literature references. Hardcopy images required digitizing into JPEG format for inclusion into a digital document. Where possible, an example was contained on one page. The atlas was reviewed by an international group of experts. A total of about 250 examples were compiled into 6 sections: planar, SPECT, whole body, camera/computer interface, environment/radioactivity, and display/hardcopy. Subtle loss of image quality may be difficult to detect. SPECT examples, therefore, include simulations demonstrating effects of deterioration in camera performance (e.g. center-of-rotation offset, non-uniformity) or suboptimal clinical performance. The atlas includes normal results, results from poor adjustment of the camera system, poor results obtained at acceptance testing, artifacts due to system malfunction, and artifacts due to environmental situations. Some image patterns are

  18. Quality control: comparison of images quality with screen film system and digital mammography CR

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Nogueira, Maria do Socorro

    2008-01-01

    The mammography screen film system should be used as part of processing chemicals, revelation process, equipment and this system has have a progressive replacing by the digital technology Full Field Digital Mammography FFDM, Computed Radiography (CR) Mammography and hardcopy. This new acquisition process of medical images has improved radiology section; however it is necessary efficient means for evaluating of the quality parameters. It should be considered taking into account the adaptation of the existent equipment and that procedures adopted for the exam, as well the adaptation of the new mammography films, the radiologist view box constitutes a part of the quality control program. This program aims at obtaining radiography with good quality that allows obtaining more information for the diagnosis and decreases the patient dose. For evaluation the quality image, this article is focused on presenting the differences regarding the acquired images through simulator mammography radiographic PMMA (Poly methyl methacrylate) in CR Mammography system and screen film system. The tests were accomplished at the same equipment of Mammography with the Automatic Exposure Control using a tension of 28 kV for both systems. The quality tests evaluated the spatial resolution, the own structures of the phantom, artifacts, optical density and contrast with conventional and laser films by mammography system. The installation for the accomplishment of the test has a quality control program. The evaluation was based on the pattern developed by the competent organ of the State of Minas Gerais. In this study, it was verified that the suitable Phantom Mama used by the Brazilian School of Radiology for conventional mammography did not obtain satisfactory result for Spatial Resolution in the digital mammography system CR. The final aim of this work is to obtain parameters to characterize the reference phantom quality image in an objective way. These parameters will be used to compare

  19. Evaluation and quality control of digital subtraction angiography systems

    International Nuclear Information System (INIS)

    Louisot, P.

    1986-04-01

    After reviewing the development of systems used in angiography, we rewind the medical interest and describe the steps of an angiographic examination. The following chapter is dedicated to the techniques used for the digitalization of video images. The components of the system involved in the image acquisition are thoroughly investigated in chapter 4. Then, we analyse the capabilities of the machines available in France in 1985. Chapter 6 is devoted to the criteria of quality in digital imaging. In order to assign qualitative values to the above criteria, we design a control procedure which is described in chapter 7. The procedure thus allows the estimate of the physical performances of angiographic digital subtraction systems [fr

  20. Radiological information systems: improvements in service, economy, and quality control?

    International Nuclear Information System (INIS)

    Gross-Fengels, W.; Weber, M.

    1997-01-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient's history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [de

  1. From quality control to quality systems in x-ray radiology. Step by step approach

    International Nuclear Information System (INIS)

    Gendrutis Morkunas; Julius Ziliukas

    2007-01-01

    Complete test of publication follows. Quality systems in x-ray radiology as in any area of medical exposure is an important tool of optimization of radiation protection. Creation of these systems is related with a number of problems: limited resources, lack of knowledge and experience, negative attitude of hospitals staff and administration, lack of advice from outside. Problems related with transitionary period might be softened by the step by step approach. The following steps might be indicated: providing information on quality systems to hospital staff and administration, simple quality control procedures done by outside experts in hospitals, preparation of quality related procedures by hospital staff, practical implementation of quality control procedures done by hospital staff, preparation of quality manual by hospital staff, its integration into common quality system of hospital (if it is available) and constant development, measurements of performance indicators (e.g., patients' doses) and introduction of corrective measures if necessary, dissemination of experience by expert organizations and more advanced hospitals. These steps are to be discussed in the presentations based on Lithuanian experience since 1998.

  2. Incentive systems for food quality control with repeated deliveries: Salmonella control in pork production

    NARCIS (Netherlands)

    King, R.P.; Backus, G.B.C.; Gaag, van der M.A.

    2007-01-01

    This paper presents a dynamic principal-agent analysis of incentive systems for Salmonella control. The European Union will require Salmonella testing from 2008. On the basis of the producer's performance history in controlling Salmonella, the incentive systems analysed determine quality premiums to

  3. EFFECT OF QUALITY CONTROL SYSTEM ON AUDIT QUALITY WITH PROFESSIONAL COMMITMENTS AS A MODERATION VARIABLE

    Directory of Open Access Journals (Sweden)

    Ramadhani R.

    2017-12-01

    Full Text Available This study aims to test the effect of every element of Quality Control System (QCS that is leadership responsibilities for quality on audit, relevant ethical requirements, acceptance and continuance of client relationships and certain engagements, assignment of engagement team, engagement performance, monitoring, and documentation on audit quality as well as to test whether the professional commitment moderate effect of every element of QCS on audit quality. The population was the staff auditors working in public accounting firms domiciled in Jakarta City, especially Central Jakarta area with the drawing of 84 respondents. The statistical method used was SEM PLS with the help of SmartPLS application. The results of this study indicate that from seven elements of QCS, only relevant ethical requirements that affect on audit quality. Furthermore, the study also found that professional commitment cannot moderate the relationship between the seven elements of QCS on audit quality.

  4. The National System for quality control and the European experience

    International Nuclear Information System (INIS)

    Dimov, A.; Vassileva, J.; Ingilizova, K.; Slavchev, A. and others

    2003-01-01

    Objective: The aim of the work is to present the structure and functions of the National System for quality control (NSQC) in the medical irradiation, created to guarantee the safety and the safe use of the radiological equipment. Material and method: The approaches are studies in the development of the NSQC, applied in Bulgaria and some European Union members - such as Germany and Great Britain - and the specifics of the way in which the Directive for medical irradiation EURATOM 97/43 is implemented in national legislations. Results: The advantages and disadvantages of Bulgarian NSQC are analysed and some ideas for tis improvement are suggested. Conclusions: The developed draft NSQC for medical irradiation is in compliance with the requirement of the European Directive. The real advantages and disadvantages of the NSQC will show after its implementation in the practical radiation protection and control in the country

  5. Design and quality control of an environmental data acquisition system

    International Nuclear Information System (INIS)

    FANJIRINDRATOVO, T.

    2009-01-01

    The present work is focused on the design of a microcontroller based measurement system and the control quality to validate it. So, a mobile instrument called DALENPA was designed to measure and log the following data: atmospheric pressure, ambient temperature, relative humidity, wind speed and direction, air dose rate, geographical coordinates by an embedded GPS receiver. The instrument is autonomous in energy by solar panel and can be connected to a PC directly or by modem. After, the quality control is based on the calibartion in a secondary laboratory. The target is to get its calibration curve and the estimation of global uncertainties. This estimation wants to include all sources of uncertainty belonging to the instrument and the secondary laboratory, and follows the method estabilished by the International Organization for Standardization (ISO) and the Bureau International des Poids et Mesures (BIPM). The calibration curve is fitted by the least squares method with uncertainties in the two variables. We got an efficient instrument with uncertainties under the limits estabilished by the regulating standards [fr

  6. A computerized diagnostic system for nuclear plant control rooms based on statistical quality control

    International Nuclear Information System (INIS)

    Heising, C.D.; Grenzebach, W.S.

    1990-01-01

    In engineering science, statistical quality control techniques have traditionally been applied to control manufacturing processes. An application to commercial nuclear power plant maintenance and control is presented that can greatly improve safety. As a demonstration of such an approach to plant maintenance and control, a specific system is analyzed: the reactor coolant pumps of the St. Lucie Unit 2 nuclear power plant located in Florida. A 30-day history of the four pumps prior to a plant shutdown caused by pump failure and a related fire within the containment was analyzed. Statistical quality control charts of recorded variables were constructed for each pump, which were shown to go out of statistical control many days before the plant trip. The analysis shows that statistical process control methods can be applied as an early warning system capable of identifying significant equipment problems well in advance of traditional control room alarm indicators

  7. Quality control of the software in the JT-60 computer control system

    International Nuclear Information System (INIS)

    Isaji, Nobuaki; Kurihara, Kenichi; Kimura, Toyoaki

    1990-07-01

    The JT-60 Control System should be improved corresponding to the experimental requirements. In order to keep the integrity of the system even in the modification the concept of quality control (QC) was introduced in the software development. What we have done for QC activity are (1) to establish standard procedures of the software development, (2) to develop support tools for grasping the present status of the program structure, and (3) to develop a document system, and a source program management system. This paper reports these QC activities and their problems for the JT-60 control system. (author)

  8. SPECT quality control tests

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.; Abe, R.

    1987-01-01

    Quality control tests of tomographic system composed by a rotatory chamber (CGR Gammatomome T-9000) and a microcomputer are presented. Traditional quality control tests for scintilation chambers and specific tests for tomographic systems are reported. (M.A.C.) [pt

  9. Quality control of rain data used for urban runoff systems

    DEFF Research Database (Denmark)

    Jørgensen, H. K.; Rosenørn, S.; Madsen, Henrik

    1998-01-01

    for collection and quality control of rain data from a network of tipping bucket rain gauges in Denmark carried out by the Danish Meteorological Institute. During rain, the RIMCO gauge counts the number of tips teach of 0.2 mm of precipitation) every minute, The quality control of the rain data includes...... an automatic and a manual bit marking, where the automatic control basically is pointing out minutes with extreme intensities. In the manual control, the maximum intensities as well as the daily totals of precipitation are inspected, using weather charts, intensity plots and precipitation sums of nearby...

  10. Production system with process quality control: modelling and application

    Science.gov (United States)

    Tsou, Jia-Chi

    2010-07-01

    Over the past decade, there has been a great deal of research dedicated to the study of quality and the economics of production. In this article, we develop a dynamic model which is based on the hypothesis of a traditional economic production quantity model. Taguchi's cost of poor quality is used to evaluate the cost of poor quality in the dynamic production system. A practical case from the automotive industry, which uses the Six-sigma DMAIC methodology, is discussed to verify the proposed model. This study shows that there is an optimal value of quality investment to make the production system reach a reasonable quality level and minimise the production cost. Based on our model, the management can adjust its investment in quality improvement to generate considerable financial return.

  11. Interaction of feel system and flight control system dynamics on lateral flying qualities

    Science.gov (United States)

    Bailey, R. E.; Knotts, L. H.

    1990-01-01

    An experimental investigation of the influence of lateral feel system characteristics on fighter aircraft roll flying qualities was conducted using the variable stability USAF NT-33. Forty-two evaluation flights were flown by three engineering test pilots. The investigation utilized the power approach, visual landing task and up-and-away tasks including formation, gun tracking, and computer-generated compensatory attitude tracking tasks displayed on the Head-Up Display. Experimental variations included the feel system frequency, force-deflection gradient, control system command type (force or position input command), aircraft roll mode time constant, control system prefilter frequency, and control system time delay. The primary data were task performance records and evaluation pilot comments and ratings using the Cooper-Harper scale. The data highlight the unique and powerful effect of the feel system of flying qualities. The data show that the feel system is not 'equivalent' in flying qualities influence to analogous control system elements. A lower limit of allowable feel system frequency appears warranted to ensure good lateral flying qualities. Flying qualities criteria should most properly treat the feel system dynamic influence separately from the control system, since the input and output of this dynamic element is apparent to the pilot and thus, does not produce a 'hidden' effect.

  12. Quality control of dosimetric systems using thermoluminescent crystals

    International Nuclear Information System (INIS)

    Mahecha, L.; Plazas, M. C.; Machado, M.; Perea, M. D.

    2006-01-01

    To achieve an optimal tumoral control to prostate cancer in early and locally advanced stages, it is necessary to increase the dose with a low mobility probability at the vesicle an rectal level. This is achieved through conformal radiotherapy. The Instituto Nacional de Cancerologia uses this technique, but two questions arise from the medical-physicists and medical radio-oncologist: In accordance with clinical protocols, the conformal radiotherapy delivers a low dose to the adjacent healthy tissues. What experimental method exists that can prove with certainly the veracity of this affirmation?. And, Do the dosimetric simulation system calculate suitable the dose for each tissues?. Through thermoluminescent dosimetry and the use of a physical simulator,we measured the absorbed dose at the target volume and the adjacent tissues using conformal and conventional radiotherapy. We proved that organs such as the rectum and bladder, receiver a minor dose in conformal radiotherapy, hence reducing their mobility probability. In addition, the readings from the thermoluminescent dosimeters and the doses calculated by the ECLIPSE dosimetric system were compared, concluding that the patient's prescribed dose is effectively delivered as recommended by the quality control program in radiotherapy. (Author)

  13. Control system of digital x-ray systems by quality parameters

    International Nuclear Information System (INIS)

    Balashov, S.V.; Kovalenko, Yu.N.

    2013-01-01

    The paper proposed a control system of X-ray digital equipment on quality indicators. Two basic parameters were determined: image quality and patients' radiation load. A method for monitoring these indicators is proposed. The criterion of equipment suitability is to obtain control digital X-ray images of diagnostically acceptable quality at a fixed low entrance dose in the plane of the digital detector. It is shown that the control system of X-ray digital equipment based on indicators of quality is the most appropriate in situations of deficit of financial resources, since minimizing the costs for the purchase and running of control systems, does not require highly skilled technical personnel, and reduces the duration of the equipment inspection. (authors)

  14. Selected parameters of moulding sands for designing quality control systems

    Directory of Open Access Journals (Sweden)

    J. Jakubski

    2010-07-01

    Full Text Available One of the modern methods of production optimisation are artificial neural networks. Neural networks owe their popularity to the fact thatthey are convenient tools, which can be utilised in a wide scope of problems. They are capable of reflecting complex functions. Especiallytheir non-linearity should be emphasised. They are gaining wider and wider application in the foundry industry, among others, to controlmelting processes in cupolas and arc furnaces, designing castings and supply systems, control of moulding sands treatments, prediction ofproperties of cast alloys as well as selecting die casting.An attempt of the application neural networks to the quality control of moulding sands with bentonite is presented in the paper. This isa method of assessing the suitability of moulding sands by finding correlations in between individual parameters, by means of artificialneural network systems. The presented investigations were performed with the application of the Statistica 8.0 program.The investigations were aimed at the selection of the proper kind of a neural network for prediction a sand moistness on the bases ofcertain moulding sand properties such as: permeability, compactibility and friability. These parameters – determined as sand moistness functions - were introduced as initial parameters.Application of the Statistica program allowed for an automatic selection of the most suitable network for the reflection of dependencies and interactions existing among the proposed parameters. The best results were obtained for unidirectional multi-layer perception network (MLP. The neural network sensitivity to individual moulding sand parameters was determined, which allowed to reject not important parameters when constructing the network.

  15. Title IV Quality Control Project, Stage II. Management Option II: Delivery System Quality Improvements.

    Science.gov (United States)

    Advanced Technology, Inc., Reston, VA.

    Stage Two of the Title IV Quality Control Project is an integrated study of quality in five related Federal financial aid programs for postsecondary students. Section 1 of the paper establishes a framework for defining quality improvements, in order to identify the types of changes that would tend to improve quality across all facets of the…

  16. Implementation of imaging of the national protocol for quality control in planning systems

    International Nuclear Information System (INIS)

    Caudepon Moreno, F.; Martin-Viera cueto, J. A.; Bodineau gil, C.; Benitez Villegas, E. M.; Casado Villalon, F. J.; Moreno Sainz, C.

    2011-01-01

    Quality control of the planning system (SP) plays a key role in quality assurance schemes that include all stages of the radiotherapy process.In this work we focus on the evidence detailing the ''Protocol for quality control in therapy planning systems with ionizing radiation of the SEFM in ''anatomical data acquisition (DA).

  17. Crop quality control system: a tool to control the visual quality of pot plants

    NARCIS (Netherlands)

    Dijkshoorn-Dekker, M.W.C.

    2002-01-01

    Key words: quality, growth, model, leaf unfolding rate, internode, plant height, plant width, leaf area, temperature, plant spacing, season, light, development, image processing, grading, neural network, pot plant, Ficus benjamina

  18. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  19. A quality control system for digital elevation data

    Science.gov (United States)

    Knudsen, Thomas; Kokkendorf, Simon; Flatman, Andrew; Nielsen, Thorbjørn; Rosenkranz, Brigitte; Keller, Kristian

    2015-04-01

    In connection with the introduction of a new version of the Danish national coverage Digital Elevation Model (DK-DEM), the Danish Geodata Agency has developed a comprehensive quality control (QC) and metadata production (MP) system for LiDAR point cloud data. The architecture of the system reflects its origin in a national mapping organization where raw data deliveries are typically outsourced to external suppliers. It also reflects a design decision of aiming at, whenever conceivable, doing full spatial coverage tests, rather than scattered sample checks. Hence, the QC procedure is split in two phases: A reception phase and an acceptance phase. The primary aim of the reception phase is to do a quick assessment of things that can typically go wrong, and which are relatively simple to check: Data coverage, data density, strip adjustment. If a data delivery passes the reception phase, the QC continues with the acceptance phase, which checks five different aspects of the point cloud data: Vertical accuracy Vertical precision Horizontal accuracy Horizontal precision Point classification correctness The vertical descriptors are comparatively simple to measure: The vertical accuracy is checked by direct comparison with previously surveyed patches. The vertical precision is derived from the observed variance on well defined flat surface patches. These patches are automatically derived from the road centerlines registered in FOT, the official Danish map data base. The horizontal descriptors are less straightforward to measure, since potential reference material for direct comparison is typically expected to be less accurate than the LiDAR data. The solution selected is to compare photogrammetrically derived roof centerlines from FOT with LiDAR derived roof centerlines. These are constructed by taking the 3D Hough transform of a point cloud patch defined by the photogrammetrical roof polygon. The LiDAR derived roof centerline is then the intersection line of the two primary

  20. [Development of quality assurance/quality control web system in radiotherapy].

    Science.gov (United States)

    Okamoto, Hiroyuki; Mochizuki, Toshihiko; Yokoyama, Kazutoshi; Wakita, Akihisa; Nakamura, Satoshi; Ueki, Heihachi; Shiozawa, Keiko; Sasaki, Koji; Fuse, Masashi; Abe, Yoshihisa; Itami, Jun

    2013-12-01

    Our purpose is to develop a QA/QC (quality assurance/quality control) web system using a server-side script language such as HTML (HyperText Markup Language) and PHP (Hypertext Preprocessor), which can be useful as a tool to share information about QA/QC in radiotherapy. The system proposed in this study can be easily built in one's own institute, because HTML can be easily handled. There are two desired functions in a QA/QC web system: (i) To review the results of QA/QC for a radiotherapy machine, manuals, and reports necessary for routinely performing radiotherapy through this system. By disclosing the results, transparency can be maintained, (ii) To reveal a protocol for QA/QC in one's own institute using pictures and movies relating to QA/QC for simplicity's sake, which can also be used as an educational tool for junior radiation technologists and medical physicists. By using this system, not only administrators, but also all staff involved in radiotherapy, can obtain information about the conditions and accuracy of treatment machines through the QA/QC web system.

  1. quality control

    International Nuclear Information System (INIS)

    Skujina, A.; Purina, S.; Riekstina, D.

    1999-01-01

    The optimal objects: soils, spruce needles and bracken ferns were found for the environmental monitoring in the regions of possible radioactive contamination - near SalaspiIs nuclear reactor and Ignalina nuclear power plant. The determination of Sr-90 was based on the radiochemical separation of Sr-90 (=Y-90) by HDEHP extraction and counting the Cerenkov radiation. The quality control of the results was carried out. (authors)

  2. Evaluation and Quality Control for the Copernicus Seasonal Forecast Systems

    Science.gov (United States)

    Manubens, N.; Hunter, A.; Bedia, J.; Bretonnière, P. A.; Bhend, J.; Doblas-Reyes, F. J.

    2017-12-01

    The EU funded Copernicus Climate Change Service (C3S) will provide authoritative information about past, current and future climate for a wide range of users, from climate scientists to stakeholders from a wide range of sectors including insurance, energy or transport. It has been recognized that providing information about the products' quality and provenance is paramount to establish trust in the service and allow users to make best use of the available information. This presentation outlines the work being conducted within the Quality Assurance for Multi-model Seasonal Forecast Products project (QA4Seas). The aim of QA4Seas is to develop a strategy for the evaluation and quality control (EQC) of the multi-model seasonal forecasts provided by C3S. First, we present the set of guidelines the data providers must comply with, ensuring the data is fully traceable and harmonized across data sets. Second, we discuss the ongoing work on defining a provenance and metadata model that is able to encode such information, and that can be extended to describe the steps followed to obtain the final verification products such as maps and time series of forecast quality measures. The metadata model is based on the Resource Description Framework W3C standard, being thus extensible and reusable. It benefits from widely adopted vocabularies to describe data provenance and workflows, as well as from expert consensus and community-support for the development of the verification and downscaling specific ontologies. Third, we describe the open source software being developed to generate fully reproducible and certifiable seasonal forecast products, which also attaches provenance and metadata information to the verification measures and enables the user to visually inspect the quality of the C3S products. QA4Seas is seeking collaboration with similar initiatives, as well as extending the discussion to interested parties outside the C3S community to share experiences and establish global

  3. Power quality control of an autonomous wind-diesel power system based on hybrid intelligent controller.

    Science.gov (United States)

    Ko, Hee-Sang; Lee, Kwang Y; Kang, Min-Jae; Kim, Ho-Chan

    2008-12-01

    Wind power generation is gaining popularity as the power industry in the world is moving toward more liberalized trade of energy along with public concerns of more environmentally friendly mode of electricity generation. The weakness of wind power generation is its dependence on nature-the power output varies in quite a wide range due to the change of wind speed, which is difficult to model and predict. The excess fluctuation of power output and voltages can influence negatively the quality of electricity in the distribution system connected to the wind power generation plant. In this paper, the authors propose an intelligent adaptive system to control the output of a wind power generation plant to maintain the quality of electricity in the distribution system. The target wind generator is a cost-effective induction generator, while the plant is equipped with a small capacity energy storage based on conventional batteries, heater load for co-generation and braking, and a voltage smoothing device such as a static Var compensator (SVC). Fuzzy logic controller provides a flexible controller covering a wide range of energy/voltage compensation. A neural network inverse model is designed to provide compensating control amount for a system. The system can be optimized to cope with the fluctuating market-based electricity price conditions to lower the cost of electricity consumption or to maximize the power sales opportunities from the wind generation plant.

  4. Quality control in radiotherapy

    International Nuclear Information System (INIS)

    Batalla, A.

    2009-01-01

    The authors discuss the modalities and periodicities of internal quality control on radiotherapy installations. They indicate the different concerned systems and the aspects and items to be controlled (patient and personnel security, apparatus mechanical characteristics, beam quality, image quality, isodose and irradiation duration calculation, data transfer). They present the measurement instruments and tools used for the mechanical controls, dose measurement, beam homogeneity and symmetry, anatomic data acquisition systems, and dose distribution and control imagery calculation

  5. Topological estimation of aerodynamic controlled airplane system functionality of quality

    Directory of Open Access Journals (Sweden)

    С.В. Павлова

    2005-01-01

    Full Text Available  It is suggested to use topological methods for stage estimation of aerodynamic airplane control in widespread range of its conditions The estimation is based on normalized stage virtual non-isotropy of configurational airplane systems calculation.

  6. Frame model of knowledge in quality control systems

    Energy Technology Data Exchange (ETDEWEB)

    Macherauskas, V.Yu.

    1982-09-01

    The purpose of this article is to develop a semiotic model for representation of data and knowledge in a system for supplying operational information to management personnel on the progress of a technological process, with the aim of enabling an analysis of deviations of product quality and formulation of recommendations to the technologists as to how to eliminate them. Since any knowledge of people that can be realistically utilized in machine systems is represented in natural language form, special languages for representation of knowledge, based on the concept of frames, are being developed for formation of semiotic models in computers. This article defines the frames, followed by a description of a mechanism of knowledge manipulation and of some aspects of realization of a frame model of knowledge. 9 references.

  7. Software quality assurance plan for the National Ignition Facility integrated computer control system

    International Nuclear Information System (INIS)

    Woodruff, J.

    1996-11-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This Software Quality Assurance Plan (SQAP) applies to the activities of the Integrated Computer Control System (ICCS) organization and its subcontractors. The Plan describes the activities implemented by the ICCS section to achieve quality in the NIF Project's controls software and implements the NIF Quality Assurance Program Plan (QAPP, NIF-95-499, L-15958-2) and the Department of Energy's (DOE's) Order 5700.6C. This SQAP governs the quality affecting activities associated with developing and deploying all control system software during the life cycle of the NIF Project

  8. Development of a quality management system for borehole investigations. (1) Quality assurance and quality control methodology for hydraulic packer testing

    International Nuclear Information System (INIS)

    Takeuchi, Shinji; Kunimaru, Takanori; Ota, Kunio; Frieg, Bernd

    2011-01-01

    A quality assurance and quality control (QA/QC) system for the hydraulic packer tests has been established based on the surface-based investigations at JAEA's underground research laboratories in Mizunami and Horonobe. The established QA/QC system covers field investigations (data acquisition) and data analysis. For the field investigations, the adopted procedure is selection of a test section based on a detail fluid logging and checking with tally list, followed by inspection of test tools such as pressure transducers and shut-in valves, etc., test method selection using a 'sequential hydraulic test' for deciding appropriate method, and finally data quality confirmation by pressure changes and derivatives on a log-log plots during testing. Test event logs should also be described during testing for traceability. For the test data analysis, a quick analysis for rough estimation of hydraulic parameters, and a detailed analysis using type curve and/or numerical analyses are conducted stepwise. The established QA/QC system has been applied to the recent borehole investigations and its efficiency has been confirmed. (author)

  9. [Discussion on research thinking of traditional Chinese medicine standardization system based on whole process quality control].

    Science.gov (United States)

    Dong, Ling; Sun, Yu; Pei, Wen-Xuan; Dai, Jun-Dong; Wang, Zi-Yu; Pan, Meng; Chen, Jiang-Peng; Wang, Yun

    2017-12-01

    The concept of "Quality by design" indicates that good design for the whole life cycle of pharmaceutical production enables the drug to meet the expected quality requirements. Aiming at the existing problems of the traditional Chinese medicine (TCM) industry, the TCM standardization system was put forward in this paper from the national strategic level, under the guidance by the idea of quality control in international manufacturing industry and with considerations of TCM industry's own characteristics and development status. The connotation of this strategy was to establish five interrelated systems: multi-indicators system based on tri-indicators system, quality standard and specification system of TCM herbal materials and decoction pieces, quality traceability system, data monitoring system based on whole-process quality control, and whole-process quality management system of TCM, and achieve the whole process systematic and scientific study in TCM industry through "top-level design-implement in steps-system integration" workflow. This article analyzed the correlation between the quality standards of all links, established standard operating procedures of each link and whole process, and constructed a high standard overall quality management system for TCM industry chains, in order to provide a demonstration for the establishment of TCM whole-process quality control system and provide systematic reference and basis for standardization strategy in TCM industry. Copyright© by the Chinese Pharmaceutical Association.

  10. Scintillation camera-computer systems: General principles of quality control

    International Nuclear Information System (INIS)

    Ganatra, R.D.

    1992-01-01

    Scintillation camera-computer systems are designed to allow the collection, digital analysis and display of the image data from a scintillation camera. The components of the computer in such a system are essentially the same as those of a computer used in any other application, i.e. a central processing unit (CPU), memory and magnetic storage. Additional hardware items necessary for nuclear medicine applications are an analogue-to-digital converter (ADC), which converts the analogue signals from the camera to digital numbers, and an image display. It is possible that the transfer of data from camera to computer degrades the information to some extent. The computer can generate the image for display, but it also provides the capability of manipulating the primary data to improve the display of the image. The first function of conversion from analogue to digital mode is not within the control of the operator, but the second type of manipulation is in the control of the operator. These type of manipulations should be done carefully without sacrificing the integrity of the incoming information

  11. Quality control in PET/CT systems. Experiences and requirements

    International Nuclear Information System (INIS)

    Geworski, Lilli; Fitz, Eduard; Knoop, Bernd; Karwarth, Cornelia; Plotkin, Michail

    2010-01-01

    Today, in most cases PET examinations are performed using PET/CT hybrid systems. While acceptance testing and routine control of the basic modalities PET and CT, respectively, are described by appropriate regulations, corresponding instructions with regard to the interface connecting both are still missing. This interface includes the adjustment of gantries and patient bed to each other as well as the energy scaling of attenuation coefficients from CT energy to 511 keV. Measurements checking the mechanical adjustment (determination of off-set parameters) are performed following manufacturer's recommendation, with a typical frequency twice a year. On a Biograph 16 (Siemens, Inc.), these measurements were systematically extended to a weekly frequency over an observation period of 10 months, supplemented by measurements with additional load to the patient bed (up to 135 kg), and different vertical bed positions. The results show, that for the construction tested additional off-set measurements for routine control extending well beyond manufacturer's recommendation are not necessary. The energy scaling of attenuation coefficients is depending on methodological aspects and software implementation, and therefore is not part of routine control. On the contrary, the development of appropriate methods for acceptance testing to assess and to determine the mechanical adjustment in all its degrees of freedom as well as the accuracy of attenuation corrected emission data is urgently needed. (orig.)

  12. Mathematical modelling and quality indices optimization of automatic control systems of reactor facility

    International Nuclear Information System (INIS)

    Severin, V.P.

    2007-01-01

    The mathematical modeling of automatic control systems of reactor facility WWER-1000 with various regulator types is considered. The linear and nonlinear models of neutron power control systems of nuclear reactor WWER-1000 with various group numbers of delayed neutrons are designed. The results of optimization of direct quality indexes of neutron power control systems of nuclear reactor WWER-1000 are designed. The identification and optimization of level control systems with various regulator types of steam generator are executed

  13. Maintenance quality surveillance for nuclear reactor instrument and control systems

    International Nuclear Information System (INIS)

    Clement, T.M.

    1976-01-01

    A description is given of a formal program of mandatory testing and inspection for assurance of reliability at the N-reactor. The techniques and procedures are called Equipment Maintenance Standards (EMS) and cover the nuclear plant systems which affect nuclear safety, environmental control, continuity of operation and reactor life. The scope of the program is such that all electrical, chemical, mechanical, and nuclear devices with interconnecting circuitry, linkages, and piping are functionally checked and/or inspected from sensors through actuating media necessary for carrying out the defined functions under startup, operating, and shutdown conditions and also under any credible accident condition. Records are kept of the AS FOUND results of the tests and inspections along with adjustments and repairs required to correct any out-of-limits conditions found. These records are accumulated and are used as a source for quantitative reliability information and for evaluating wear-out or design problems

  14. Software product quality control

    CERN Document Server

    Wagner, Stefan

    2013-01-01

    Quality is not a fixed or universal property of software; it depends on the context and goals of its stakeholders. Hence, when you want to develop a high-quality software system, the first step must be a clear and precise specification of quality. Yet even if you get it right and complete, you can be sure that it will become invalid over time. So the only solution is continuous quality control: the steady and explicit evaluation of a product's properties with respect to its updated quality goals.This book guides you in setting up and running continuous quality control in your environment. Star

  15. Development of a data base system for quality control of MOX fuels

    International Nuclear Information System (INIS)

    Takahashi, Kuniaki; Yamaguchi, Toshihiro; Mishima, Takeshi

    1988-01-01

    For the purpose of improvement and speed up of work concerning quality control for mixed oxide fuel fabrication, we have been developing a data base system having a data base consisting of data as to fabrication conditions and inspects, We have aimed to develop a data base system having capability of analysis and function giving informations as to quality control. The data base system is full interactive system on real time basis, consequently it makes analyzing and editing data easy. It has capability of relational research, numerical analysis, correlation analysis, drawing control charts, histograms, and other figures, and expressing status of fabrication processes using control charts. (author)

  16. Maps of sharpness: a methodology to present results of quality control for mammographic system

    International Nuclear Information System (INIS)

    Oliveira, Henrique Jesus Quintino de; Marques, Marcio Alexandre; Frere, Annie France; Schiable, Homero; Marques, Paulo M. Azevedo; Irita, Ricardo Toshiyuki

    1996-01-01

    A new method for evaluating radiologic imaging systems quality is presented. This method intends to relate the numeric results from quality control procedures to the magnitude of shadow and penumbra in the image from given objects. This evaluation is based on a computer simulation and it can be performed for any system and any object placed in any location of the radiation field

  17. Proposal of Effective Quality Control and Insurance System of Construction Industry

    OpenAIRE

    Kawarasaki, Yuta; Nasu, Seigo

    2007-01-01

    In this research, the kinds and the number of defective qualities are examined, and the current state of the defective quality is understood. In addition, a social cost led by analyzing the quality control cost function and the quality insurance cost function in making optimal balance, and requesting a total cost are analyzed. The insurance system that adds the parameter of citizen’s senses of trust at the end leading to an ideal social cost in evaluating the optimal construction management l...

  18. Expert system for quality control in the INIS database

    International Nuclear Information System (INIS)

    Todeschini, C.; Tolstenkov, A.

    1990-05-01

    An expert system developed to identify input items to INIS database with a high probability of containing errors is described. The system employs a Knowledge Base constructed by the interpretation of a large number of intellectual choices or expert decisions made by human indexers and incorporated in the INIS database. On the basis of the descriptor indexing, the system checks the correctness of the categorization. A notable feature of the system is its capability of self improvement by the continuous updating of the Knowledge Base. The expert system has also been found to be extremely useful in identifying documents with poor indexing. 3 refs, 9 figs

  19. Expert system for quality control in the INIS database

    Energy Technology Data Exchange (ETDEWEB)

    Todeschini, C; Tolstenkov, A [International Atomic Energy Agency, Vienna (Austria)

    1990-05-01

    An expert system developed to identify input items to INIS database with a high probability of containing errors is described. The system employs a Knowledge Base constructed by the interpretation of a large number of intellectual choices or expert decisions made by human indexers and incorporated in the INIS database. On the basis of the descriptor indexing, the system checks the correctness of the categorization. A notable feature of the system is its capability of self improvement by the continuous updating of the Knowledge Base. The expert system has also been found to be extremely useful in identifying documents with poor indexing. 3 refs, 9 figs.

  20. Quality Control Of Compton Suppression System As An Environmental Sample Counting System

    International Nuclear Information System (INIS)

    Siswohartoyo, Sudarti; Soepardi, Dewita

    1996-01-01

    Quality control on Compton Suppression System has been done, i.e : 1) testing of HPGe as the main detector (FWHM, P/C d c level /n oise ) , 2) the Nal(Tl) detector shielding characteristic, 3) timing spectrum (FWHM), and 4) suppression factor. From the collected data, the characteristic of HPGe were found to be in the same range as shown in the manual. From the Nal(Tl) testing, it was found that the resolution was about 9%. From the time spectrum testing, the resolution was about 12-13 ns, while the suppression factor measurement was found to be about 4 - 4.6

  1. Expert system for quality control in bibliographic databases

    International Nuclear Information System (INIS)

    Todeschini, C.; Farrell, M.P.

    1989-01-01

    An Expert System is presented that can identify errors in the intellectual decisions made by indexers when categorizing documents into an a priori category scheme. The system requires the compilation of a Knowledge Base that incorporates in statistical form the decisions on the linking of indexing and categorization derived from a preceding period of the bibliographic database. New input entering the database is checked against the Knowledge Base, using the descriptor indexing assigned to each record, and the system computed a value for the match of each record with the particular category chosen by the indexer. This category match value is used as a criterion for identifying those documents that have been erroneously categorized. The system was tested on large sample of almost 26,000 documents, representing all the literature falling into ten of the subject categories of the Energy Data Base during the five year period 1980-1984. For valid comparisons among categories, the Knowledge Base must be constructed with an approximately equal number of unique descriptors for each subject category. The system identified those items with high probability of having been erroneously categorized. These items, constituting up to 5% of the sample, were evaluated manually by subject specialists for correct categorization and then compared with the results of the Expert System. Of those pieces of literature deemed by the system to be erroneously categorized, about 75% did indeed belong to a different category. This percentage, however, is dependent on the level at which the threshold on the category match value is set. With a lower threshold value, the percentage can be raised to 90%, but this is accompanied by a lowering of the absolute number of wrongly categorized records caught by the system. The Expert System can be considered as a first step to complete semiautomatic categorizing system

  2. Systems and methods for data quality control and cleansing

    Science.gov (United States)

    Wenzel, Michael; Boettcher, Andrew; Drees, Kirk; Kummer, James

    2016-05-31

    A method for detecting and cleansing suspect building automation system data is shown and described. The method includes using processing electronics to automatically determine which of a plurality of error detectors and which of a plurality of data cleansers to use with building automation system data. The method further includes using processing electronics to automatically detect errors in the data and cleanse the data using a subset of the error detectors and a subset of the cleansers.

  3. Importance of implementing an analytical quality control system in a core laboratory.

    Science.gov (United States)

    Marques-Garcia, F; Garcia-Codesal, M F; Caro-Narros, M R; Contreras-SanFeliciano, T

    2015-01-01

    The aim of the clinical laboratory is to provide useful information for screening, diagnosis and monitoring of disease. The laboratory should ensure the quality of extra-analytical and analytical process, based on set criteria. To do this, it develops and implements a system of internal quality control, designed to detect errors, and compare its data with other laboratories, through external quality control. In this way it has a tool to detect the fulfillment of the objectives set, and in case of errors, allowing corrective actions to be made, and ensure the reliability of the results. This article sets out to describe the design and implementation of an internal quality control protocol, as well as its periodical assessment intervals (6 months) to determine compliance with pre-determined specifications (Stockholm Consensus(1)). A total of 40 biochemical and 15 immunochemical methods were evaluated using three different control materials. Next, a standard operation procedure was planned to develop a system of internal quality control that included calculating the error of the analytical process, setting quality specifications, and verifying compliance. The quality control data were then statistically depicted as means, standard deviations, and coefficients of variation, as well as systematic, random, and total errors. The quality specifications were then fixed and the operational rules to apply in the analytical process were calculated. Finally, our data were compared with those of other laboratories through an external quality assurance program. The development of an analytical quality control system is a highly structured process. This should be designed to detect errors that compromise the stability of the analytical process. The laboratory should review its quality indicators, systematic, random and total error at regular intervals, in order to ensure that they are meeting pre-determined specifications, and if not, apply the appropriate corrective actions

  4. External Quality Control Review of the Defense Information Systems Agency Audit Organization

    Science.gov (United States)

    2012-08-07

    We are providing this report for your information and use. We have reviewed the system of quality control for the audit organization of the Defense...audit organization encompasses the audit organization’s leadership, emphasis on performing high quality work, and policies and procedures established

  5. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  6. Software quality assurance plan for the National Ignition Facility integrated computer control system

    Energy Technology Data Exchange (ETDEWEB)

    Woodruff, J.

    1996-11-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This Software Quality Assurance Plan (SQAP) applies to the activities of the Integrated Computer Control System (ICCS) organization and its subcontractors. The Plan describes the activities implemented by the ICCS section to achieve quality in the NIF Project`s controls software and implements the NIF Quality Assurance Program Plan (QAPP, NIF-95-499, L-15958-2) and the Department of Energy`s (DOE`s) Order 5700.6C. This SQAP governs the quality affecting activities associated with developing and deploying all control system software during the life cycle of the NIF Project.

  7. Using Vision Metrology System for Quality Control in Automotive Industries

    Science.gov (United States)

    Mostofi, N.; Samadzadegan, F.; Roohy, Sh.; Nozari, M.

    2012-07-01

    The need of more accurate measurements in different stages of industrial applications, such as designing, producing, installation, and etc., is the main reason of encouraging the industry deputy in using of industrial Photogrammetry (Vision Metrology System). With respect to the main advantages of Photogrammetric methods, such as greater economy, high level of automation, capability of noncontact measurement, more flexibility and high accuracy, a good competition occurred between this method and other industrial traditional methods. With respect to the industries that make objects using a main reference model without having any mathematical model of it, main problem of producers is the evaluation of the production line. This problem will be so complicated when both reference and product object just as a physical object is available and comparison of them will be possible with direct measurement. In such case, producers make fixtures fitting reference with limited accuracy. In practical reports sometimes available precision is not better than millimetres. We used a non-metric high resolution digital camera for this investigation and the case study that studied in this paper is a chassis of automobile. In this research, a stable photogrammetric network designed for measuring the industrial object (Both Reference and Product) and then by using the Bundle Adjustment and Self-Calibration methods, differences between the Reference and Product object achieved. These differences will be useful for the producer to improve the production work flow and bringing more accurate products. Results of this research, demonstrate the high potential of proposed method in industrial fields. Presented results prove high efficiency and reliability of this method using RMSE criteria. Achieved RMSE for this case study is smaller than 200 microns that shows the fact of high capability of implemented approach.

  8. USING VISION METROLOGY SYSTEM FOR QUALITY CONTROL IN AUTOMOTIVE INDUSTRIES

    Directory of Open Access Journals (Sweden)

    N. Mostofi

    2012-07-01

    Full Text Available The need of more accurate measurements in different stages of industrial applications, such as designing, producing, installation, and etc., is the main reason of encouraging the industry deputy in using of industrial Photogrammetry (Vision Metrology System. With respect to the main advantages of Photogrammetric methods, such as greater economy, high level of automation, capability of noncontact measurement, more flexibility and high accuracy, a good competition occurred between this method and other industrial traditional methods. With respect to the industries that make objects using a main reference model without having any mathematical model of it, main problem of producers is the evaluation of the production line. This problem will be so complicated when both reference and product object just as a physical object is available and comparison of them will be possible with direct measurement. In such case, producers make fixtures fitting reference with limited accuracy. In practical reports sometimes available precision is not better than millimetres. We used a non-metric high resolution digital camera for this investigation and the case study that studied in this paper is a chassis of automobile. In this research, a stable photogrammetric network designed for measuring the industrial object (Both Reference and Product and then by using the Bundle Adjustment and Self-Calibration methods, differences between the Reference and Product object achieved. These differences will be useful for the producer to improve the production work flow and bringing more accurate products. Results of this research, demonstrate the high potential of proposed method in industrial fields. Presented results prove high efficiency and reliability of this method using RMSE criteria. Achieved RMSE for this case study is smaller than 200 microns that shows the fact of high capability of implemented approach.

  9. System for verifiable CT radiation dose optimization based on image quality. part II. process control system.

    Science.gov (United States)

    Larson, David B; Malarik, Remo J; Hall, Seth M; Podberesky, Daniel J

    2013-10-01

    To evaluate the effect of an automated computed tomography (CT) radiation dose optimization and process control system on the consistency of estimated image noise and size-specific dose estimates (SSDEs) of radiation in CT examinations of the chest, abdomen, and pelvis. This quality improvement project was determined not to constitute human subject research. An automated system was developed to analyze each examination immediately after completion, and to report individual axial-image-level and study-level summary data for patient size, image noise, and SSDE. The system acquired data for 4 months beginning October 1, 2011. Protocol changes were made by using parameters recommended by the prediction application, and 3 months of additional data were acquired. Preimplementation and postimplementation mean image noise and SSDE were compared by using unpaired t tests and F tests. Common-cause variation was differentiated from special-cause variation by using a statistical process control individual chart. A total of 817 CT examinations, 490 acquired before and 327 acquired after the initial protocol changes, were included in the study. Mean patient age and water-equivalent diameter were 12.0 years and 23.0 cm, respectively. The difference between actual and target noise increased from -1.4 to 0.3 HU (P process control chart identified several special causes of variation. Implementation of an automated CT radiation dose optimization system led to verifiable simultaneous decrease in image noise variation and SSDE. The automated nature of the system provides the opportunity for consistent CT radiation dose optimization on a broad scale. © RSNA, 2013.

  10. Real time quality control of meteorological data used in SRP's emergency response system

    International Nuclear Information System (INIS)

    Pendergast, M.M.

    1980-05-01

    The Savannah River Laboratory's WIND minicomputer system allows quick and accurate assessment of an accidental release at the Savannah River Plant using data from eight meteorological towers. The accuracy of the assessment is largely determined by the accuracy of the meteorological data; therefore quality control is important in an emergency response system. Real-time quality control of this data will be added to the WIND system to automatically identify inaccurate data. Currently, the system averages the measurements from the towers to minimize the influence of inaccurate data being used in calculations. The computer code used in the real-time quality control has been previously used to identify inaccurate measurements from the archived tower data

  11. Control of Refrigeration Systems for Trade-off between Energy Consumption and Food Quality Loss

    DEFF Research Database (Denmark)

    Cai, Junping

    In supermarkets, control strategies determine both the energy consumption of refrigeration systems and the quality loss of refrigerated foodstuffs. The question is, what can be done to optimize the balance between quality loss and energy consumption? This thesis tries to answer this question...... by applying two main optimization strategies to traditional refrigeration systems. The first strategy is a new defrost-on-demand scheme, which based on an objective function between quality loss and energy consumption, continuously seeks an optimal time interval for defrosting in dynamic situation. The second...... strategy is through utilization of the thermal mass of the refrigerated foodstuffs, the day-night temperature variation and the capacity control of the compressor, to realize a trade-off between system energy consumption and food quality loss....

  12. HVAC SYSTEMS AS A TOOL IN CONTROLLING INDOOR AIR QUALITY: A LITERATURE REVIEW

    Science.gov (United States)

    The report gives results of a review of literature on the use of heating, ventilating, and air-conditioning (HVAC) systems to control indoor air quality (IAQ). Although significant progress has been made in reducing the energy consumption of HVAC systems, their effect on indoor a...

  13. Toward city-scale water quality control: building a theory for smart stormwater systems

    Science.gov (United States)

    Kerkez, B.; Mullapudi, A. M.; Wong, B. P.

    2016-12-01

    Urban stormwater systems are rarely designed as actual systems. Rather, it is often assumed that individual Best Management Practices (BMPs) will add up to achieve desired watershed outcomes. Given the rise of BMPs and green infrastructure, we ask: does doing "best" at the local scale guarantee the "best" at the global scale? Existing studies suggest that the system-level performance of distributed stormwater practices may actually adversely impact watersheds by increasing downstream erosion and reducing water quality. Optimizing spatial placement may not be sufficient, however, since precipitation variability and other sources of uncertainty can drive the overall system into undesirable states. To that end, it is also important to control the temporal behavior of the system, which can be achieved by equipping stormwater elements (ponds, wetlands, basins, bioswales, etc.) with "smart" sensors and valves. Rather than building new infrastructure, this permits for existing assets to be repurposed and controlled to adapt to individual storm events. While we have learned how to build and deploy the necessary sensing and control technologies, we do not have a framework or theory that combines our knowledge of hydrology, hydraulics, water quality and control. We discuss the development of such a framework and investigate how existing water domain knowledge can be transferred into a system-theoretic context to enable real-time, city-scale stormwater control. We apply this framework to water quality control in an urban watershed in southeast Michigan, which has been heavily instrumented and retrofitted for control over the past year.

  14. In-house quality audit and benefits of some quality control procedures in the quality assurance of TL dosimetry system at NRPB

    International Nuclear Information System (INIS)

    Dutt, J.C.

    1993-01-01

    A number of Quality Control (QC) procedures have been introduced into the running and operation of the NRPB personal monitoring services. Those described here apply to the whole-body TL dosimetry system. These QC procedures comprise Quality Assurance (QA) of incoming raw materials and equipment, reader stabilisation, daily, routine and periodic QA checks on all phases of the service. In-house quality audit, periodic internal and external 'blind QA checks' on the dosimetry system as a whole have assured the continuing high quality and reliability of the NRPB TL dosimetry service for assessing body and skin doses of radiation workers from external photon and beta radiations. (author)

  15. Tradeoffs between quality-of-control and quality-of-service in large-scale nonlinear networked control systems

    NARCIS (Netherlands)

    Borgers, D. P.; Geiselhart, R.; Heemels, W. P. M. H.

    2017-01-01

    In this paper we study input-to-state stability (ISS) of large-scale networked control systems (NCSs) in which sensors, controllers and actuators are connected via multiple (local) communication networks which operate asynchronously and independently of each other. We model the large-scale NCS as an

  16. A quality control method by ultrasonic vibration energy and diagnosis system at trimming process

    International Nuclear Information System (INIS)

    Suh, Chang Min; Song, Gil Ho; Pyoun, Young Shik

    2007-01-01

    In this paper, the characteristics in mechanical properties of ultrasonic cold forging treatment (UCFT) used for the trimming knife and the effects of ultrasonic vibration energy (UVE) into the trimming process on the state of the strip cutting face were studied. And a diagnosis system to quality control for trimming knife and strip cutting face was developed and installed in plant. By the plant application of UCFT, service life of knife was more increased over 100% than that of conventional knife and using the developed diagnosis system, the knife breakage and saw ear have been perfectly detected and quality control of trimming face is effectively obtained

  17. Quality control in haemostasis.

    Science.gov (United States)

    Capel, P; Chatelain, B; Leclerq, R; Lust, A; Masure, R; Arnout, J

    1992-01-01

    Laboratory investigation of the haemostatic system deserves particular procedures in the quality control of analytical variables as well as preanalytical variables. This paper reviews the precautions that have to be taken in the blood prelevement, the transport of the tubes and the performance of the laboratory tests aimed to investigate the haemostatic system in order to obtain reliable results.

  18. Implementation of quality control systems in laboratories in Paraguay by the participants of ARCAL LXXVI project

    International Nuclear Information System (INIS)

    Villanueva, Z.

    2004-12-01

    In the Project ARCAL LXXVII, was realized the National Course of Control of Quality of Analytic Laboratories, from 12 to 16 of April in the CNEA, Paraguay, as a result of the one mentioned course was elaborated this project whose purpose is to elaborate the necessary documentation to fulfill the requirements of administration in the Analytic Laboratories to be adapted to the system of quality according to the ISO 17025 [es

  19. Preliminary measurements of the establishment of a quality control programme for the activimeter calibration reference system

    International Nuclear Information System (INIS)

    Martins, Elaine W.; Potiens, Maria da Penha A.

    2009-01-01

    The nuclear medicine techniques efficiency and safety depends on, beside other factors, a quality control programme, mainly regards to the nuclides activimeter utilization. The Calibration Laboratory of IPEN uses as a work standard, a tertiary standard system Capintec, calibrated at the Accredited Dosimetry Calibration Laboratory of the Medical radiation Research Center - University of Wisconsin. In this work, as preliminary measurements to establish a quality control programme for the activimeter calibration procedures, initially the repeatability and reproducibility (long term stability) tests were performed using a sealed check source of 133 Ba. Later on, to complete this quality control programme other check sources ( 137 Cs, 57 Co, 60 Co) will be used to perform the same tests. A series of 80 experiments of 10 measurements each has been carried out. The reference system showed a good behaviour to the repeatability test, considering the tolerance limits of 5%. The percent deviations of all tested sources in the activity measurements were lower 1% to 133 Ba. (author)

  20. Software quality assurance and software safety in the Biomed Control System

    International Nuclear Information System (INIS)

    Singh, R.P.; Chu, W.T.; Ludewigt, B.A.; Marks, K.M.; Nyman, M.A.; Renner, T.R.; Stradtner, R.

    1989-01-01

    The Biomed Control System is a hardware/software system used for the delivery, measurement and monitoring of heavy-ion beams in the patient treatment and biology experiment rooms in the Bevalac at the Lawrence Berkeley Laboratory (LBL). This paper describes some aspects of this system including historical background philosophy, configuration management, hardware features that facilitate software testing, software testing procedures, the release of new software quality assurance, safety and operator monitoring. 3 refs

  1. Quality control beam of radiation through imaging system using a flat panel (ILD)

    International Nuclear Information System (INIS)

    Benitez Serrano, J. A.; Gomez Barrado, A.; Sanchez-Reyes, A.

    2013-01-01

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  2. Therapeutic intervention at cellular quality control systems in Alzheimer's and Parkinson's diseases.

    Science.gov (United States)

    Arduino, Daniela M; Esteves, A Raquel; Silva, Diana F F; Martins-Branco, Diogo; Santos, Daniel; Pimentel, Diana F Gomes; Cardoso, Sandra M

    2011-01-01

    Cellular homeostasis relies on quality control systems so that damaged biologic structures are either repaired or degraded and entirely replaced by newly formed proteins or even organelles. The clearance of dysfunctional cellular structures in long-lived postmitotic cells, like neurons, is essential to eliminate, per example, defective mitochondria, lipofuscin-loaded lysosomes and oxidized proteins. Short-lived proteins are degraded mainly by proteases and proteasomes whether most long-lived proteins and all organelles are digested by autophagy in the lysosomes. Recently, it an interplay was established between the ubiquitin-proteasome system and macroautophagy, so that both degradative mechanisms compensate for each other. In this article we describe each of these clearance systems and their contribution to neuronal quality control. We will highlight some of the findings that provide evidence for the dysfunction of these systems in Alzheimer's and Parkinson's diseases. Ultimately, we provide an outline on potential therapeutic interventions based on the modulation of cellular degradative systems.

  3. Quality control of software in dissimilar systems using a common clinical data base

    International Nuclear Information System (INIS)

    Erickson, J.J.; Price, R.R.; Touya, J.J.; Kronenberg, M.W.; Pederson, R.; Rollo, F.D.

    1980-01-01

    For a long time there has been widespread interest in the quality control of diagnostic instrumentation. The increasing dependence on computational systems for clinical results makes it imperative that methods for quality control of diagnostic software be developed. This paper proposes a method based on the use of a collection of patient studies for which the results have been corroborated by independent methods. The data set will be distributed in a format requiring no special handling by the system being tested and will appear identical to studies actually collected by the host system. An example of the use of a preliminary version of the data set for comparison of two systems is shown. The comparison shows that analyses performed on the two systems agree very well and can be reliably compared for follow-up studies of a patient

  4. Development of nuclear power plant online monitoring system using statistical quality control

    International Nuclear Information System (INIS)

    An, Sang Ha

    2006-02-01

    Statistical Quality Control techniques have been applied to many aspects of industrial engineering. An application to nuclear power plant maintenance and control is also presented that can greatly improve plant safety. As a demonstration of such an approach, a specific system is analyzed: the reactor coolant pumps (RCP) and the fouling resistance of heat exchanger. This research uses Shewart X-bar, R charts, Cumulative Sum charts (CUSUM), and Sequential Probability Ratio Test (SPRT) to analyze the process for the state of statistical control. And we made Control Chart Analyzer (CCA) to support these analyses that can make a decision of error in process. The analysis shows that statistical process control methods can be applied as an early warning system capable of identifying significant equipment problems well in advance of traditional control room alarm indicators. Such a system would provide operators with enough time to respond to possible emergency situations and thus improve plant safety and reliability

  5. Design of Energy Storage Control Strategy to Improve the PV System Power Quality

    DEFF Research Database (Denmark)

    Lei, Mingyu; Yang, Zilong; Wang, Yibo

    2016-01-01

    Random fluctuation of PV power is becoming a more and more serious problem affecting the power quality and stability of grid as the PV penetration keeps increasing recent years. Aiming at this problem, this paper proposed a control strategy of energy storage system based on Model Predictive Contr...

  6. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Kristensen, K.

    1981-01-01

    Quality assurance was introduced in the pharmaceutical field long before it was used in many other areas, and the term quality control has been used in a much broader sense than merely analytical quality control. The term Good Manufacturing Practice (GMP) has been used to describe the system used for producing safe and effective drugs of a uniform quality. GMP has also been used for the industrial production of radiopharmaceuticals. For the preparation and control of radiopharmaceuticals in hospitals a similar system has been named Good Radiopharmacy Practice (GRP). It contains the same elements as GMP but takes into account the special nature of this group of drugs. Data on the assessment of the quality of radiopharmaceuticals in relation to present standards are reviewed. The general conclusion is that the quality of radiopharmaceuticals appears comparable to that of other drugs. It seems possible to establish the production of radiopharmaceuticals, generators and preparation kits in such a way that analytical control of the final product at the hospital may be limited provided the final preparation work is carried out in accordance with GRP principles. The elements of GRP are reviewed. (author)

  7. Optimization of spatial light distribution through genetic algorithms for vision systems applied to quality control

    International Nuclear Information System (INIS)

    Castellini, P; Cecchini, S; Stroppa, L; Paone, N

    2015-01-01

    The paper presents an adaptive illumination system for image quality enhancement in vision-based quality control systems. In particular, a spatial modulation of illumination intensity is proposed in order to improve image quality, thus compensating for different target scattering properties, local reflections and fluctuations of ambient light. The desired spatial modulation of illumination is obtained by a digital light projector, used to illuminate the scene with an arbitrary spatial distribution of light intensity, designed to improve feature extraction in the region of interest. The spatial distribution of illumination is optimized by running a genetic algorithm. An image quality estimator is used to close the feedback loop and to stop iterations once the desired image quality is reached. The technique proves particularly valuable for optimizing the spatial illumination distribution in the region of interest, with the remarkable capability of the genetic algorithm to adapt the light distribution to very different target reflectivity and ambient conditions. The final objective of the proposed technique is the improvement of the matching score in the recognition of parts through matching algorithms, hence of the diagnosis of machine vision-based quality inspections. The procedure has been validated both by a numerical model and by an experimental test, referring to a significant problem of quality control for the washing machine manufacturing industry: the recognition of a metallic clamp. Its applicability to other domains is also presented, specifically for the visual inspection of shoes with retro-reflective tape and T-shirts with paillettes. (paper)

  8. Dosimetric systems developed in Brazil for the radiation processes quality control

    International Nuclear Information System (INIS)

    Galante, Ana Maria Sisti; Campos, Leticia Lucente

    2011-01-01

    In order to apply new technologies to the industrial processing of materials aiming economy, efficiency, speed and high quality, ionizing radiation has been used in medicine, archaeology, chemistry, food preservation and other areas. For this reason, the dosimetry area looks for improve current dosimeters and develop new materials for application on quality control of these processes. In Brazil, the research in the dosimetry area occurs with great speed providing many different dosimetric systems. The chemical dosimetry is the most used technique in routine dosimetry, which requires fast and accurate responses. This technique involves determination of absorbed dose by measuring chemical changes radiation induced in the materials. Different dosimetric systems were developed at IPEN for application on radiation process quality and all of them present excellent results; the low cost of these materials allows a more effective dose control, therefore, a larger area or volume can be monitored. (author).

  9. [Development of whole process quality control and management system of traditional Chinese medicine decoction pieces based on traditional Chinese medicine quality tree].

    Science.gov (United States)

    Yu, Wen-Kang; Dong, Ling; Pei, Wen-Xuan; Sun, Zhi-Rong; Dai, Jun-Dong; Wang, Yun

    2017-12-01

    The whole process quality control and management of traditional Chinese medicine (TCM) decoction pieces is a system engineering, involving the base environment, seeds and seedlings, harvesting, processing and other multiple steps, so the accurate identification of factors in TCM production process that may induce the quality risk, as well as reasonable quality control measures are very important. At present, the concept of quality risk is mainly concentrated in the aspects of management and regulations, etc. There is no comprehensive analysis on possible risks in the quality control process of TCM decoction pieces, or analysis summary of effective quality control schemes. A whole process quality control and management system for TCM decoction pieces based on TCM quality tree was proposed in this study. This system effectively combined the process analysis method of TCM quality tree with the quality risk management, and can help managers to make real-time decisions while realizing the whole process quality control of TCM. By providing personalized web interface, this system can realize user-oriented information feedback, and was convenient for users to predict, evaluate and control the quality of TCM. In the application process, the whole process quality control and management system of the TCM decoction pieces can identify the related quality factors such as base environment, cultivation and pieces processing, extend and modify the existing scientific workflow according to their own production conditions, and provide different enterprises with their own quality systems, to achieve the personalized service. As a new quality management model, this paper can provide reference for improving the quality of Chinese medicine production and quality standardization. Copyright© by the Chinese Pharmaceutical Association.

  10. Interaction between production control and quality control

    NARCIS (Netherlands)

    Bij, van der J.D.; Ekert, van J.H.W.

    1999-01-01

    Describes a qualitative study on interaction between systems for production control and quality control within industrial organisations. Production control and quality control interact in a sense. Good performance for one aspect often influences or frustrates the performance of the other. As far as

  11. [Quality control an assessment system. Its location within a program for food, nutrition and metabolic intervention].

    Science.gov (United States)

    Santana Porbén, S

    2012-01-01

    A design proposal for a HQCAS Hospital Quality Control and Assessment System of the nutritional and feeding care processes conducted in a hospital environment is presented in this article. The design proposal is accompanied of the results of inspections conducted by the hospital NST Nutritional Support Group between 2005-2010. The system design includes quality policies that should rule the useful and safe conduction of such processes, the recording and documentary foundations of the System, and the quality control and assessment exercises for the continuous verification of such established policies. The current state of the conduction of these processes was documented from secondary records opened by the NST after satisfying consultation requests from the medical care teams of the institution. Inspections conducted by the NST revealed that less than half of clinical charts contained information minimally enough for elaborating nutritional judgments, almost one-fifth of the assisted patients were on Nils Per Oris, for whom no nutritional support schemes were prescribed, and a low prescription and usage of artificial nutrition schemes. Corrective measures adopted by the NST served to significantly increase the rates of successful completion of inspected processes. Quality assurance of feeding and nutritional care processes is a practical as well as an intellectual activity subjected to constant remodeling, in order to always warrant the fulfillment of quality policies advanced by the NST, and thus, that the patient benefits from the prescribed nutritional intervention strategy.

  12. Analyze for the Quality Control of General X-ray Systems in Capital region

    International Nuclear Information System (INIS)

    Kang, Byung Sam; Lee, Kang Min; Shin, Woo Yong; Park, Soon Chul; Choi, Hak Dong; Cho, Yong Kwon

    2012-01-01

    Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

  13. Organization of a system of guarantee of quality for the control of specifications of chemical reagents

    International Nuclear Information System (INIS)

    Bustamante Gutierrez, M. G.

    2000-01-01

    Analytic methods were implemented based on valuations acid-base and redox for the quantitative determination of sodium hidroxid, iodine and iron chloride III, like part of a system of quality for the technical specifications of these reagents. The planning of its system of quality includes two fundamental parts: insurance and control of quality. In the insurance part the state of operation of the team that you uses settled down, gauges the one that achieve to maintain under the supervision of a single operator (electronic equip and glassware) and the design of the appropriate documents settled down to carry out the periodic supervision of the acting of the same ones and other aspects characteristic of the system (experimental results). Also protocolized and validated the analytic methods to use following the approaches of precision given by ASTM, organism whose methodologies are recognized in the country like official; other procedures, as that of calibration of the volumetric equipments, they were also protocolized. In the part of control of quality, the limits settled down and procedures were applied the scales and used other, to the necessary distilled water to carry out the determinations and to the used chemical reagents. With base in the obtained results you determines that the analyzed reagents fulfill the specifications of ACS (and with those reported by the maker) at the same time settled down that the laboratory 09 of the Chemistry School, used in a large part of development of this project, it didn't fulfill the necessary requirements so that it works as laboratory of control of quality. As an alternative, the administration of the School outlines as solution the use of the Laboratory of Insurance of the Quality from the Unit of Service to the Industry for such end [es

  14. Design and Development of a Nearable Wireless System to Control Indoor Air Quality and Indoor Lighting Quality

    Directory of Open Access Journals (Sweden)

    Francesco Salamone

    2017-05-01

    Full Text Available The article describes the results of the project “open source smart lamp” aimed at designing and developing a smart object able to manage and control the indoor environmental quality (IEQ of the built environment. A first version of this smart object, built following a do-it-yourself (DIY approach using a microcontroller, an integrated temperature and relative humidity sensor, and techniques of additive manufacturing, allows the adjustment of the indoor thermal comfort quality (ICQ, by interacting directly with the air conditioner. As is well known, the IEQ is a holistic concept including indoor air quality (IAQ, indoor lighting quality (ILQ and acoustic comfort, besides thermal comfort. The upgrade of the smart lamp bridges the gap of the first version of the device providing the possibility of interaction with the air exchange unit and lighting system in order to get an overview of the potential of a nearable device in the management of the IEQ. The upgraded version was tested in a real office equipped with mechanical ventilation and an air conditioning system. This office was occupied by four workers. The experiment is compared with a baseline scenario and the results show how the application of the nearable device effectively optimizes both IAQ and ILQ.

  15. The IEO Data Center Management System: Tools for quality control, analysis and access marine data

    Science.gov (United States)

    Casas, Antonia; Garcia, Maria Jesus; Nikouline, Andrei

    2010-05-01

    Since 1994 the Data Centre of the Spanish Oceanographic Institute develops system for archiving and quality control of oceanographic data. The work started in the frame of the European Marine Science & Technology Programme (MAST) when a consortium of several Mediterranean Data Centres began to work on the MEDATLAS project. Along the years, old software modules for MS DOS were rewritten, improved and migrated to Windows environment. Oceanographic data quality control includes now not only vertical profiles (mainly CTD and bottles observations) but also time series of currents and sea level observations. New powerful routines for analysis and for graphic visualization were added. Data presented originally in ASCII format were organized recently in an open source MySQL database. Nowadays, the IEO, as part of SeaDataNet Infrastructure, has designed and developed a new information system, consistent with the ISO 19115 and SeaDataNet standards, in order to manage the large and diverse marine data and information originated in Spain by different sources, and to interoperate with SeaDataNet. The system works with data stored in ASCII files (MEDATLAS, ODV) as well as data stored within the relational database. The components of the system are: 1.MEDATLAS Format and Quality Control - QCDAMAR: Quality Control of Marine Data. Main set of tools for working with data presented as text files. Includes extended quality control (searching for duplicated cruises and profiles, checking date, position, ship velocity, constant profiles, spikes, density inversion, sounding, acceptable data, impossible regional values,...) and input/output filters. - QCMareas: A set of procedures for the quality control of tide gauge data according to standard international Sea Level Observing System. These procedures include checking for unexpected anomalies in the time series, interpolation, filtering, computation of basic statistics and residuals. 2. DAMAR: A relational data base (MySql) designed to

  16. Quality Control System using Simple Implementation of Seven Tools for Batik Textile Manufacturing

    Science.gov (United States)

    Ragil Suryoputro, Muhammad; Sugarindra, Muchamad; Erfaisalsyah, Hendy

    2017-06-01

    In order to produce better products and mitigate defect in products, every company must implement a quality control system. Company will find means to implement a quality control system that is capable and reliable. One of the methods is using the simple implementation of the seven tools in quality control defects. The case studied in this research was the level of disability xyz grey fabric on a shuttle loom 2 on the Batik manufacturing company. The seven tools that include: flowchart, check sheet, histogram, scatter diagram combined with control charts, Pareto diagrams and fishbone diagrams (causal diagram). Check sheet results obtained types of defects in the grey fabric was woven xyz is warp, double warp, the warp break, double warp, empty warp, warp tenuous, ugly edges, thick warp, and rust. Based on the analysis of control chart indicates that the process is out of control. This can be seen in the graph control where there is still a lot of outlier data. Based on a scatter diagram shows a positive correlation between the percentage of disability and the number of production. Based on Pareto diagram, repair needs priority is for the dominant type of defect is warp (44%) and based on double warp value histogram is also the highest with a value of 23635.11 m. In addition, based on the analysis of the factors causing defect by fishbone diagram double warp or other types of defects originating from the materials, methods, machines, measurements, man and environment. Thus the company can take to minimize the prevention and repair of defects and improve product quality.

  17. Quality assurance as a system of management control in nuclear power plants

    International Nuclear Information System (INIS)

    Raisic, N.

    1986-04-01

    Quality assurance is considered as a management control system which the owner of a nuclear power plant has to establish for a nuclear power project for ensuring that a plant is built as designed and that defects are corrected. The building up of such a system should start early enough in project activities and before the plant design and construction, in order to ensure correct performance of all activities related to selection of the site for the nuclear power plant, bid specification and evaluation and procurement of services. The QA is a regulatory requirement, but the prudent plant management would create such a system as part of their total project management systems irrespective of formulation of requirement. In fact regulatory requirement should be considered as the criteria to be used by the regulatory organization for evaluation of licensee's QA system and not as an objective to be reached. In this paper the needs for QA system are justified as part of the development of industrial infrastructure for the nuclear power project. Elements of the system are described such as documented QA programme and organizational structures with defined responsibility and functions of individual organizational units, and with control of information flow across the interfaces. The goals and objectives or the project organizations related to achievement and verification of quality are defined as well as system functions in attaining these objectives. This includes the feedback of information to the management on monitoring of performance in project activities, identifying deficiencies and initiating corrective actions. Domestic participation in the nuclear power plant construction will depend on the ability of local construction and manufacturing organizations to achieve high quality standards of products and services that can affect safety and performance of the nuclear power plant. Introduction of QA systems in project organizations, development of QA programme and

  18. Environmental radiation control and quality management system in design and operation of sealed radioactive sources

    International Nuclear Information System (INIS)

    Hussein, A.Z.

    2007-01-01

    New environmental regulations and radiation safety standards are being implemented almost daily to ensure radiation safety, in particular for practices causing exposures to undue radiation doses. A particular emphasis of real challenge for organizations and users of radiation sources has to be for proper radiological safety assessment and is becoming cost effectively to be prepared for auditing. Special concern for the environment is of global . nature, and hence environmental auditing has been and will continue to be an essential practice for improving the environment and for meeting the relevant regulations and standards. In general, most facilities that deal with radioactive sources undertake strict safety measures in terms of personnel radiation protection, handling procedures and security. Hence, those measures should comply with the requirements of the environmental protection standards. Accordingly, a successful quality management system must balance realities of organization and personnel in achieving quality objectives. Organizational principles are found in the technical aspects of' quality management, such as, charting, requirements, measurements, procedures, ... , etc. Human principles are found in the communication side of quality management (e.g. meetings, ,decision making, ,teams, ... , etc). The quality management must understand and balance skills needed to blend them together. Large gamma irradiators present a high potential radiation hazard to the surrounding environment, since the amount of radioactivity is of the order of (P Bq) and a very high dose rates are produced during irradiation. Application of environmental radiation control deemed by regulatory authority and a proper quality management system by the utility would serve public health and safety

  19. An automatic system for controlling the quality of straws installed in the ATLAS TRT detector

    CERN Document Server

    Golunov, A O; Gousakov, Yu V; Kekelidze, G D; Livinski, V V; Mouraviev, S V; Parzycki, S S; Peshekhonov, V D; Price, M J; Savenkov, A A

    2004-01-01

    This article describes an automatic system to control the quality of straws installed in the wheels of the end-cap Transition Radiation Tracker of the ATLAS experiment. The system tests both the straightness and the electrical insulation of the straws during installation. The testing time per straw is 9s; consequently it takes about 2h to measure one layer of straws. The off-line analysis takes 20s per straw. With this system defects can be immediately detected and corrected. This clearly influences the future performance of the detector.

  20. Development of a quality control system in intensity modulated radiotherapy (IMRT)

    International Nuclear Information System (INIS)

    Souza, Roberto Salomon de; Braz, Delson

    2013-01-01

    The more complex the technique of radiotherapy is, the more refined the quality control must be. The technique of Intensity Modulated Radiotherapy (IMRT) is one of the technological innovations that gained space in the whole worlds in the last decade whose parameters of quality control are not fully established yet. The present work developed a phantom for quality control in IMRT to be implemented in the routine of the Radiotherapy Quality Control Program (PQRT) of the Brazilian National Cancer Institute (INCa). The device consists of a block formed by several polystyrene slice with TDLs and radiochromic film inserted. It should be sent (or taken) to the Program participating institutions to be irradiated under certain conditions and then be returned to the PQRT., where the discrepancy degree between the planned treatment and those effectively delivered will be evaluated. The system was validated through the test cases and the pilot program preformed in nine radiotherapy centers that perform IMRT in the southeast region of Brazil. (author)

  1. Base for a remote quality control system for magnetic resonance images machines

    International Nuclear Information System (INIS)

    Gonzalez Dalmau, Evelio R; Cabal Mirabal, Carlos; Noda Guerra, Manuel

    2014-01-01

    The medical images systems convert characteristic of the tissues in gray levels or color, using a physical method and a specific mathematical transformation. In Magnetic Resonance Images (MRI) these levels have a multi-parametric dependence, this a reason of their strong presence in the daily clinical practice. This technological complexity, the high costs and the importance that have these study for the patient's life, confer to the Quality Control (QC) human, technological, economic and juridical implications. Several international groups dedicated to the QC in MRI and diversity of approaches to carry out the tests of acceptance and periodic control of the quality exist. The characterization is habitually carried out, with global methods that don't allow a detailed quantitative parametric study. A novel system of quantitative control was developed based on quantitative describers by slices and temporal. This system is formed for: 1) standard methodology of acquisition of the experimental data, 2) subsystem of functions and programs developed in MatLab, 3) subsystem of graphics and reports, and 4) the expert. It is used successfully in the characterization and the periodic control of MRI machines of several magnetic fields in Cuba and in Venezuela. They were defined and established quantitative descriptors for MRI machines. The software flexibility allows carry out the QC to any machine facilitating the standardization and its use in multi-center studies. The retrospective and predictive value of the system was demonstrated. They feel the bases for the remote realization of the test

  2. Quality control of mammography

    International Nuclear Information System (INIS)

    Hering, K.G.

    1986-01-01

    Random checks of mammograms allow to clearly assess quality controls concerning correct application and operation of the radiographic system indicated by rich contrast in breast tissue images, complete imaging of the mammary parenchyma, freedom from blurs due to motion, efficient breast compression, correct film labelling and perfect maintenance of the film screen system. In addition to these subjective assessments, the following points should be considered when using objective measurement procedures and phantoms: Testing the correct function of X-ray and radiographic equipment by means of test specimens to measure KV standard (KV=Association of German Panel Doctors), mAS and automatic exposure timer; comparing dose and density to initial values and checking film processing by using a sensitometer. Quality assurance handling varies from one KV to the next. That is why the users need to obtain the guidelines of the respective KV relative to radiological quality assurance and to proceed according to these. (orig.) [de

  3. Machine Vision-Based Measurement Systems for Fruit and Vegetable Quality Control in Postharvest.

    Science.gov (United States)

    Blasco, José; Munera, Sandra; Aleixos, Nuria; Cubero, Sergio; Molto, Enrique

    Individual items of any agricultural commodity are different from each other in terms of colour, shape or size. Furthermore, as they are living thing, they change their quality attributes over time, thereby making the development of accurate automatic inspection machines a challenging task. Machine vision-based systems and new optical technologies make it feasible to create non-destructive control and monitoring tools for quality assessment to ensure adequate accomplishment of food standards. Such systems are much faster than any manual non-destructive examination of fruit and vegetable quality, thus allowing the whole production to be inspected with objective and repeatable criteria. Moreover, current technology makes it possible to inspect the fruit in spectral ranges beyond the sensibility of the human eye, for instance in the ultraviolet and near-infrared regions. Machine vision-based applications require the use of multiple technologies and knowledge, ranging from those related to image acquisition (illumination, cameras, etc.) to the development of algorithms for spectral image analysis. Machine vision-based systems for inspecting fruit and vegetables are targeted towards different purposes, from in-line sorting into commercial categories to the detection of contaminants or the distribution of specific chemical compounds on the product's surface. This chapter summarises the current state of the art in these techniques, starting with systems based on colour images for the inspection of conventional colour, shape or external defects and then goes on to consider recent developments in spectral image analysis for internal quality assessment or contaminant detection.

  4. Improving Code Quality of the Compact Muon Solenoid Electromagnetic Calorimeter Control Software to Increase System Maintainability

    CERN Multimedia

    Holme, Oliver; Dissertori, Günther; Djambazov, Lubomir; Lustermann, Werner; Zelepoukine, Serguei

    2013-01-01

    The Detector Control System (DCS) software of the Electromagnetic Calorimeter (ECAL) of the Compact Muon Solenoid (CMS) experiment at CERN is designed primarily to enable safe and efficient operation of the detector during Large Hadron Collider (LHC) data-taking periods. Through a manual analysis of the code and the adoption of ConQAT [1], a software quality assessment toolkit, the CMS ECAL DCS team has made significant progress in reducing complexity and improving code quality, with observable results in terms of a reduction in the effort dedicated to software maintenance. This paper explains the methodology followed, including the motivation to adopt ConQAT, the specific details of how this toolkit was used and the outcomes that have been achieved. [1] ConQAT, Continuous Quality Assessment Toolkit; https://www.conqat.org/

  5. Application of the suggestion system in the improvement of the production process and product quality control

    Science.gov (United States)

    Gołaś, H.; Mazur, A.; Gruszka, J.; Szafer, P.

    2016-08-01

    The elaboration is a case study and the research was carried out in the company Alco-Mot Ltd., which employs 120 people. The company specializes in the production of lead poles for industrial and traction batteries using gravity casting. The elements embedded in the cast are manufactured on a machining centre, which provides the stability of the process and of the dimensions of the product as well as a very short production time. As a result of observation and analysis the authors have developed a concept for the implementation of a dynamic suggestion system in ALCO-MOT, including, among others, a standard for actions in the implementation of the suggestion system, as well as clear guidelines for the processing and presentation of the activities undertaken in the time between the establishment of the concept (suggestions) and the benefits analysis after the proposed solutions have been implemented. The authors also present how suggestions proposed by ALCO-MOT staff contributed to the improvement of the processes of production and quality control. Employees offered more than 30 suggestions, of which more than a half are being implemented now and further actions are being prepared for implementation. The authors will present the results of improvements in, for example, tool replacement time, scrap reduction. The authors will present how kaizen can improve the production and quality control processes. They will present how the production and quality control processes looked before and after the implementation of employee suggestions.

  6. Quality data systems

    International Nuclear Information System (INIS)

    Bergman, J.E.; Patterson, R.G.

    1976-01-01

    General Electric's Nuclear Fuel Department data system strategy of multifunctional system integration and specific applications of data systems for the Quality Assurance Programme is detailed. Descriptions of two manufacturing control systems and their function in satisfying quality data requirements are included. The timesharing quality data system developed for processing laboratory, traceability and material release data in the Fuel Manufacturing Operation is described. In addition, specific references are made to those areas where significant time reductions have been realized through the utilization of mechanized data-handling systems. (author)

  7. As we age: Does slippage of quality control in the immune system lead to collateral damage?

    Science.gov (United States)

    Müller, Ludmila; Pawelec, Graham

    2015-09-01

    The vertebrate adaptive immune system is remarkable for its possession of a very broad range of antigen receptors imbuing the system with exquisite specificity, in addition to the phagocytic and inflammatory cells of the innate system shared with invertebrates. This system requires strict control both at the level of the generation the cells carrying these receptors and at the level of their activation and effector function mediation in order to avoid autoimmunity and mitigate immune pathology. Thus, quality control checkpoints are built into the system at multiple nodes in the response, relying on clonal selection and regulatory networks to maximize pathogen-directed effects and minimize collateral tissue damage. However, these checkpoints are compromised with age, resulting in poorer immune control manifesting as tissue-damaging autoimmune and inflammatory phenomena which can cause widespread systemic disease, paradoxically compounding the problems associated with increased susceptibility to infectious disease and possibly cancer in the elderly. Better understanding the reasons for slippage of immune control will pave the way for developing rational strategies for interventions to maintain appropriate immunity while reducing immunopathology. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Quality control of calibration system for area monitors at National Laboratory of Metrology from Ionizing Radiations (LNMRI)

    International Nuclear Information System (INIS)

    Ramos, M.M.O.; Freitas, L.C. de

    1992-01-01

    The quality control of equipment used in calibration from the National Laboratory of Metrology on Ionizing Radiations is presented, with results of standard measure systems and irradiation system. Tables and graphics with the quality of systems are also shown. (C.G.C.)

  9. Implementation of Cyber-Physical Production Systems for Quality Prediction and Operation Control in Metal Casting

    Directory of Open Access Journals (Sweden)

    JuneHyuck Lee

    2018-05-01

    Full Text Available The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT, artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry.

  10. Implementation of Cyber-Physical Production Systems for Quality Prediction and Operation Control in Metal Casting

    Science.gov (United States)

    Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin

    2018-01-01

    The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry. PMID:29734699

  11. Implementation of Cyber-Physical Production Systems for Quality Prediction and Operation Control in Metal Casting.

    Science.gov (United States)

    Lee, JuneHyuck; Noh, Sang Do; Kim, Hyun-Jung; Kang, Yong-Shin

    2018-05-04

    The prediction of internal defects of metal casting immediately after the casting process saves unnecessary time and money by reducing the amount of inputs into the next stage, such as the machining process, and enables flexible scheduling. Cyber-physical production systems (CPPS) perfectly fulfill the aforementioned requirements. This study deals with the implementation of CPPS in a real factory to predict the quality of metal casting and operation control. First, a CPPS architecture framework for quality prediction and operation control in metal-casting production was designed. The framework describes collaboration among internet of things (IoT), artificial intelligence, simulations, manufacturing execution systems, and advanced planning and scheduling systems. Subsequently, the implementation of the CPPS in actual plants is described. Temperature is a major factor that affects casting quality, and thus, temperature sensors and IoT communication devices were attached to casting machines. The well-known NoSQL database, HBase and the high-speed processing/analysis tool, Spark, are used for IoT repository and data pre-processing, respectively. Many machine learning algorithms such as decision tree, random forest, artificial neural network, and support vector machine were used for quality prediction and compared with R software. Finally, the operation of the entire system is demonstrated through a CPPS dashboard. In an era in which most CPPS-related studies are conducted on high-level abstract models, this study describes more specific architectural frameworks, use cases, usable software, and analytical methodologies. In addition, this study verifies the usefulness of CPPS by estimating quantitative effects. This is expected to contribute to the proliferation of CPPS in the industry.

  12. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  13. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    International Nuclear Information System (INIS)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P.

    2011-01-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  14. Automation system for quality control in manufacture of iodine-125 sealed sources used in brachytherapy

    Energy Technology Data Exchange (ETDEWEB)

    Somessari, Samir L.; Feher, Anselmo; Sprenger, Francisco E.; Rostellato, Maria E.C.M.; Moura, Joao A.; Costa, Osvaldo L.; Calvo, Wilson A.P., E-mail: somessar@ipen.b, E-mail: afeher@ipen.b, E-mail: sprenger@ipen.b, E-mail: elisaros@ipen.b, E-mail: olcosta@ipen.b, E-mail: wapcalvo@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    The objective of this work is to develop an automation system for Quality Control in the production of Iodine-125 sealed sources, after undergoing the process of laser beam welding. These sources, also known as Iodine-125 seeds are used, successfully, in the treatment of cancer by brachytherapy, with low-dose rates. Each small seed is composed of a welded titanium capsule with 0.8 mm diameter and 4.5 mm in length, containing Iodine-125 adsorbed on an internal silver wire. The seeds are implanted in the human prostate to irradiate the tumor and treat the cancerous cells. The technology to automate the quality control system in the manufacture of Iodine-125 seeds consists in developing and associate mechanical parts, electronic components and pneumatic circuits to control machines and processes. The automation technology for Iodine-125 seed production developed in this work employs programmable logic controller, step motors, drivers of control, electrical-electronic interfaces, photoelectric sensors, interfaces of communication and software development. Industrial automation plays an important role in the production of Iodine-125 seeds, with higher productivity and high standard of quality, facilitating the implementation and operation of processes with good manufacturing practices. Nowadays, the Radiation Technology Center at IPEN-CNEN/SP imports and distributes 36,000 Iodine-125 seeds per year for clinics and hospitals in the whole country. However, the Brazilian potential market is of 8,000 Iodine-125 seeds per month. Therefore, the local production of these radioactive seeds has become a priority for the Institute, aiming to reduce the price and increase the supply to the population in Brazil. (author)

  15. Quality Control Applications

    CERN Document Server

    Chorafas, Dimitris N

    2013-01-01

    Quality control is a constant priority in electrical, mechanical, aeronautical, and nuclear engineering – as well as in the vast domain of electronics, from home appliances to computers and telecommunications. Quality Control Applications provides guidance and valuable insight into quality control policies; their methods, their implementation, constant observation and associated technical audits. What has previously been a mostly mathematical topic is translated here for engineers concerned with the practical implementation of quality control. Once the fundamentals of quality control are established, Quality Control Applications goes on to develop this knowledge and explain how to apply it in the most effective way. Techniques are described and supported using relevant, real-life, case studies to provide detail and clarity for those without a mathematical background. Among the many practical examples, two case studies dramatize the importance of quality assurance: A shot-by-shot analysis of the errors made ...

  16. Testing and Quality Assurance of the Control System During NIF Commissioning

    International Nuclear Information System (INIS)

    Casavant, D.; Carey, R.; Cline, B.; Lagin, L.; Ludwigsen, P.; Reddi, U.; Van Arsdall, P.

    2003-01-01

    The strategy used to develop the National Ignition Facility Integrated Computer Control System (NIF ICCS) calls for incremental cycles of construction and formal test to deliver nearly one million lines of code. Software releases that implement specific functionality are approved for deployment when offline tests conducted in the ICCS Integration and Test Facility verify functional, performance and interface requirements using test procedures derived from system requirements. At this stage of the project the controls team has delivered approximately 3/4 of the planned software by performing dozens of development and test cycles within offline test facilities and followed by online tests to confirm integrated operation in the NIF. Test incidents are recorded and tracked from development to successful deployment by the verification team, with hardware and software changes approved by the appropriate change control board. Project metrics are generated by the Software Quality Assurance manager and monitored by ICCS management. Test results are summarized and reported to responsible individuals and Project managers under a work authorization and permit process that assesses risk and evaluates control system upgrade readiness. NIF is well into the first phases of its laser commissioning program to characterize and operate the first four laser beams and target systems. The integrated control system has successfully fired over 100 coordinated shots into beam diagnostics and an initial set of target diagnostics in the 10-m diameter target chamber. Extensive experience has been gained by integrating controls in prototype laboratories and in the NIF. This paper will discuss NIF's software QC and QA processes, capabilities of offline test facilities, and metrics collection

  17. Testing and Quality Assurance of the Control System During NIF Commissioning

    Energy Technology Data Exchange (ETDEWEB)

    Casavant, D; Carey, R; Cline, B; Lagin, L; Ludwigsen, P; Reddi, U; Van Arsdall, P

    2003-10-13

    The strategy used to develop the National Ignition Facility Integrated Computer Control System (NIF ICCS) calls for incremental cycles of construction and formal test to deliver nearly one million lines of code. Software releases that implement specific functionality are approved for deployment when offline tests conducted in the ICCS Integration and Test Facility verify functional, performance and interface requirements using test procedures derived from system requirements. At this stage of the project the controls team has delivered approximately 3/4 of the planned software by performing dozens of development and test cycles within offline test facilities and followed by online tests to confirm integrated operation in the NIF. Test incidents are recorded and tracked from development to successful deployment by the verification team, with hardware and software changes approved by the appropriate change control board. Project metrics are generated by the Software Quality Assurance manager and monitored by ICCS management. Test results are summarized and reported to responsible individuals and Project managers under a work authorization and permit process that assesses risk and evaluates control system upgrade readiness. NIF is well into the first phases of its laser commissioning program to characterize and operate the first four laser beams and target systems. The integrated control system has successfully fired over 100 coordinated shots into beam diagnostics and an initial set of target diagnostics in the 10-m diameter target chamber. Extensive experience has been gained by integrating controls in prototype laboratories and in the NIF. This paper will discuss NIF's software QC and QA processes, capabilities of offline test facilities, and metrics collection.

  18. [Practical aspects of implementation quality management system ISO 9001:2000 by hospital infection control team].

    Science.gov (United States)

    Kuziemski, Arkadiusz; Czerniak, Beata; Frankowska, Krystyna; Gonia, Ewa; Salińska, Teresa; Motuk, Andrzej; Sobociński, Zbigniew

    2009-01-01

    In 2006 the Board of the Jan Biziel Hospital in Bydgoszcz decided to include procedures of health services in the implementation process within the confines of ISO 9001:2000 certification. The hospital infection control team that has operated in the hospital since 1989 performed the analysis of the forms of activities to date and on that basis the team prepared original plan of quality management. In April 2007, this plan was successfully accepted by the certifying team. The aim of this study is to present the aforementioned plan which is the result of 18 years experience of the team. At the same time, I hope that this study will be very helpful for all professionals interested in hospital epidemiology, especially in the context of implementing quality management systems.

  19. Development of a dosimetric system for the quality control of breast cancer treatments

    International Nuclear Information System (INIS)

    Chaves, Roberio C.; Crispim, Verginia R.; Santos, Delano B.V.

    2013-01-01

    A system for evaluating the values of absorbed dose in breast teletherapy was developed, using thermoluminescent dosimeters (TLD-100), to compare them to those provided by Therapy planning system. A breast phantom was made to distribute the dosimeters TL shaped chip in breast volume and irradiate it under the same conditions of planning. Three different techniques of teletherapy were considered: one with irradiation from a therapy unit of 60 Co and two with an X-ray beam coming from a 6 MV linear accelerator. Doses measures allowed checking that the performance of the quality control system used in breast cancer treatment is appropriate, since the planned doses differed about 1.5% of the responses provided by TL dosimeters

  20. Commercial jet fuel quality control

    Energy Technology Data Exchange (ETDEWEB)

    Strauss, K.H.

    1995-05-01

    The paper discusses the purpose of jet fuel quality control between the refinery and the aircraft. It describes fixed equipment, including various types of filters, and the usefulness and limitations of this equipment. Test equipment is reviewed as are various surveillance procedures. These include the Air Transport Association specification ATA 103, the FAA Advisory Circular 150/5230-4, the International Air Transport Association Guidance Material for Fuel Quality Control and Fuelling Service and the Guidelines for Quality Control at Jointly Operated Fuel Systems. Some past and current quality control problems are briefly mentioned.

  1. Gust Wind Effects on Stability and Ride Quality of Actively Controlled Maglev Guideway Systems

    Directory of Open Access Journals (Sweden)

    Dong-Ju Min

    2017-01-01

    Full Text Available The purpose of this paper is to present a framework to analyze the interaction between an actively controlled magnetic levitation vehicle and a guideway structure under gusty wind. The equation of motion is presented for a 30-dof maglev vehicle model consisting of one cabin and four bogies. In addition, a lateral electromagnetic suspension (EMS system is introduced to improve the running safety and ride quality of the maglev vehicle subjected to turbulent crosswind. By using the developed simulation tools, the effects of various parameters on the dynamic response of the vehicle and guideway are investigated in the case of the UTM maglev vehicle running on a simply supported guideway and cable-stayed guideway. The simulation results show that the independent lateral EMS and associated control scheme are definitely helpful in improving the running safety and ride quality of the vehicle under gusty wind. In the case of the cable-stayed guideway, at low wind speed, vehicle speed is the dominant factor influencing the dynamic responses of the maglev vehicle and the guideway, but at wind speed over 10 m/s, wind becomes the dominant factor. For the ride quality of the maglev vehicle, wind is also the most influential factor.

  2. [Quality process control system of Chinese medicine preparation based on "holistic view"].

    Science.gov (United States)

    Wang, Ya-Qi; Jiao, Jiao-Jiao; Wu, Zhen-Feng; Zheng, Qin; Yang, Ming

    2018-01-01

    "High quality, safety and effectiveness" are the primary principles for the pharmaceutical research and development process in China. The quality of products relies not only on the inspection method, but also on the design and development, process control and standardized management. The quality depends on the process control level. In this paper, the history and current development of quality control of traditional Chinese medicine (TCM) preparations are reviewed systematically. Based on the development model of international drug quality control and the misunderstanding of quality control of TCM preparations, the reasons for impacting the homogeneity of TCM preparations are analyzed and summarized. According to TCM characteristics, efforts were made to control the diversity of TCM, make "unstable" TCM into "stable" Chinese patent medicines, put forward the concepts of "holistic view" and "QbD (quality by design)", so as to create the "holistic, modular, data, standardized" model as the core of TCM preparation quality process control model. Scientific studies shall conform to the actual production of TCM preparations, and be conducive to supporting advanced equipment and technology upgrade, thoroughly applying the scientific research achievements in Chinese patent medicines, and promoting the cluster application and transformation application of TCM pharmaceutical technology, so as to improve the quality and effectiveness of the TCM industry and realize the green development. Copyright© by the Chinese Pharmaceutical Association.

  3. The Czech External Quality Control system in medical microbiology and parasitology.

    Science.gov (United States)

    Slosárek, M; Kríz, B

    2000-11-01

    The External Quality Control (EQC) system in activities of laboratories engaged in medical microbiology and parasitology was established in the Czech Republic in 1993 when to the first laboratories which applied coded serum samples were sent for diagnosis of viral hepatitis and bacterial strains for identification. In the course of years the number of control areas increased and in 2000 there were 31 and the number of those interested in participation in EQC increased from 79 in 1993 to 434 in 2000. This year a total of 13,239 samples will be sent to laboratories. Gradually thus almost all microbiological and parasitological laboratories concerned with examination of clinical material became involved. Seven-year experience with EQC in the Czech Republic revealed that gradually the results of various examinations became more accurate, that methods became standardized and the most suitable examination sets are used.

  4. Control of quality in the tests of systems of containment of vehicles. Intercomparison of the results of the tests

    International Nuclear Information System (INIS)

    Lopez Ramos, S.

    2009-01-01

    This article tries to offer information on how Central Laboratory of Structures and Materials are made the tests for Marca N of AENOR of the systems of containment of vehicles and its control of external quality. (Author) 15 refs

  5. Quality management system

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Mu Sung

    2009-08-15

    This book deals with ISO9001 quality management system which includes summary of this system such as classification of quality, principle of quality management, and definition, requirement and procedure of quality management system, introduction of ISO9001 system like model of ISO9001 quality management system, ISO certificate system, structure of ISO9001 standard, requirement of ISO9001 quality management system, process approach and documentation of system, propel cases of ISO9001 quality management system.

  6. Quality management system

    International Nuclear Information System (INIS)

    Lee, Mu Sung

    2009-08-01

    This book deals with ISO9001 quality management system which includes summary of this system such as classification of quality, principle of quality management, and definition, requirement and procedure of quality management system, introduction of ISO9001 system like model of ISO9001 quality management system, ISO certificate system, structure of ISO9001 standard, requirement of ISO9001 quality management system, process approach and documentation of system, propel cases of ISO9001 quality management system.

  7. Printing quality control automation

    Science.gov (United States)

    Trapeznikova, O. V.

    2018-04-01

    One of the most important problems in the concept of standardizing the process of offset printing is the control the quality rating of printing and its automation. To solve the problem, a software has been developed taking into account the specifics of printing system components and the behavior in printing process. In order to characterize the distribution of ink layer on the printed substrate the so-called deviation of the ink layer thickness on the sheet from nominal surface is suggested. The geometric data construction the surface projections of the color gamut bodies allows to visualize the color reproduction gamut of printing systems in brightness ranges and specific color sectors, that provides a qualitative comparison of the system by the reproduction of individual colors in a varying ranges of brightness.

  8. Review of selected contributions of the conference 'Project control in quality management systems'

    International Nuclear Information System (INIS)

    2008-04-01

    There were 12 contributions presented of the conference focused on the project management in quality management systems. Contributions were focused both on theoretical problems from the project management area and on the applications in practice in management systems implementation in accordance with the standards: STN EN ISO 9001:2000, STN EN ISO 14 001:2005, and OHSAS 18 001:1999. One contribution was focused on the project management in the project of preparation of finishing of the building of the Nuclear Power Plant Mochovce of 3. and 4. block and one contribution was focused on the amendment of the Atomic Act or on the preparation of the new Atomic Act with regard to duty of transposition of the Directive of the Council 2006/117/Euratom on control and supervision of the overseas transportations of radioactive waste and nuclear fuel burnt-up into legislation of the Slovak Republic

  9. Development and implementation of a quality control system for bentonite materials

    International Nuclear Information System (INIS)

    Kiviranta, Leena; Schatz, Timothy; Autio, Jorma; Korkeakoski, Petri

    2010-01-01

    Document available in extended abstract form only. This work describes the development and implementation of a quality control system for bentonite material from initial acquisition to processing. The system is designed to provide an efficient, cost-effective, and reliable means of ensuring the sufficient quality of bentonite destined for use in the engineered barrier system of a repository for spent nuclear fuel. The program is outlined and includes three test categories: Basic Acceptance Testing, Advanced Acceptance Testing, and Complementary Testing. Basic acceptance testing is to be performed for any and all bentonite material considered for use in the repository. These tests are designed to quickly determine whether the material meets at least a basic level of acceptance. If the material passes basic acceptance testing, it progresses to the advanced acceptance testing regime. If the acquired material originates over multiple source lots, basic and advanced acceptance testing are performed for each. Complementary testing is performed when necessary or requested. B plus Tech has developed the in-house capability and competence to perform the majority of the tests and built a network (in Finland) of reliable, external partners and providers for the remainder. (authors)

  10. Set up and operation for medical radiation exposure quality control system of health promotion center

    International Nuclear Information System (INIS)

    Kim, Jung Su; Kim, Jung Min; Jung, Hae Kyoung

    2016-01-01

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm"2 and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure

  11. Set up and operation for medical radiation exposure quality control system of health promotion center

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jung Su; Kim, Jung Min [Korea University,Seoul (Korea, Republic of); Jung, Hae Kyoung [Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA University, Sungnam (Korea, Republic of)

    2016-03-15

    In this study, standard model of medical radiation dosage quality control system will be suggested and the useful of this system in clinical field will be reviewed. Radiation dosage information of modalities are gathered from digital imaging and communications in medicine(DICOM) standard data(such as DICOM dose SR and DICOM header) and stored in database. One CT scan, two digital radiography modalities and two mammography modalities in one health promotion center in Seoul are used to derive clinical data for one month. After 1 months research with 703 CT scans, the study shows CT 357.9 mGy·cm in abdomen and pelvic CT, 572.4 mGy·cm in brain without CT, 55.9 mGy·cm in calcium score/heart CT, screening CT at 54 mGy·cm in chest screening CT(low dose screening CT scan), 284.99 mGy·cm in C-spine CT and 341.85 mGy·cm in L-spine CT as health promotion center reference level of each exam. And with 1955 digital radiography cases, it shows 274.0 mGy·cm{sup 2} and for mammography 6.09 mGy is shown based on 536 cases. The use of medical radiation shall comply with the principles of justification and optimization. This quality management of medical radiation exposure must be performed in order to follow the principle. And the procedure to reduce the radiation exposure of patients and staff can be achieved through this. The results of this study can be applied as a useful tool to perform the quality control of medical radiation exposure.

  12. Checking quality control?

    DEFF Research Database (Denmark)

    Brodersen, Lars

    2005-01-01

    How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?......How is quality control doing within the community of GIS, web-services based on geo-information, GI etc.?...

  13. Glandular dose and image quality control in mammography facilities with computerized radiography systems

    International Nuclear Information System (INIS)

    Dantas, Marcelino Vicente de Almeida

    2010-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  14. Digital systems to acquire radiological imaging. Characteristics and quality control; Sistemas digitales de adquisicion de imagenes radiograficas. Caracteristicas y Control de Calidad

    Energy Technology Data Exchange (ETDEWEB)

    Torres Cabrera, R.; Hernando Gonzalez, I.

    2006-07-01

    Due to its special characteristics, quality control in digital radiographic systems is very important, even more than in conventional film-screen systems. Differences between digital and analogical images,a in terms of dynamics range, spatial and contrast resolution, and the flexibility of data post-processing require some actions to maintain clinical images in an optimum quality level. Revision 1 of the Spanish Protocol of Quality Control in Diagnostic Radiology includes a chapter dedicated to the quality control of these digital systems for the acquisition of radiographic images. In this paper the different parameters for quality control procedures are described. Also some difficulties to be concerned about (absence of levels of tolerance, access to the raw-data images and related information, availability of use anthropomorphic phantoms, etc, etc) are noted, as well as the most significant aspects of the differences in relation to the ana logical systems. (Author) 15 refs.

  15. A whole process quality control system for energy measuring instruments inspection based on IOT technology

    Science.gov (United States)

    Yin, Bo; Liu, Li; Wang, Jiahan; Li, Xiran; Liu, Zhenbo; Li, Dewei; Wang, Jun; Liu, Lu; Wu, Jun; Xu, Tingting; Cui, He

    2017-10-01

    Electric energy measurement as a basic work, an accurate measurements play a vital role for the economic interests of both parties of power supply, the standardized management of the measurement laboratory at all levels is a direct factor that directly affects the fairness of measurement. Currently, the management of metering laboratories generally uses one-dimensional bar code as the recognition object, advances the testing process by manual management, most of the test data requires human input to generate reports. There are many problems and potential risks in this process: Data cannot be saved completely, cannot trace the status of inspection, the inspection process isn't completely controllable and so on. For the provincial metrology center's actual requirements of the whole process management for the performance test of the power measuring appliances, using of large-capacity RF tags as a process management information media, we developed a set of general measurement experiment management system, formulated a standardized full performance test process, improved the raw data recording mode of experimental process, developed a storehouse automatic inventory device, established a strict test sample transfer and storage system, ensured that all the raw data of the inspection can be traced back, achieved full life-cycle control of the sample, significantly improved the quality control level and the effectiveness of inspection work.

  16. Towards a quality-controlled and accessible Pitzer model for seawater and related systems

    Directory of Open Access Journals (Sweden)

    David Turner

    2016-09-01

    Full Text Available We elaborate the need for a quality-controlled chemical speciation model for seawater and related natural waters, work which forms the major focus of SCOR Working Group 145. Model development is based on Pitzer equations for the seawater electrolyte and trace components. These equations can be used to calculate activities of dissolved ions and molecules and, in combination with thermodynamic equilibrium constants, chemical speciation. The major tasks to be addressed are ensuring internal consistency of the Pitzer model parameters (expressing the interactions between pairs and triplets of species, which ultimately determines the calculated activities, assessing uncertainties, and identifying important data gaps that should be addressed by new measurements. It is recognised that natural organic matter plays an important role in many aquatic ecosystems, and options for including this material in a Pitzer-based model are discussed. The process of model development begins with the core components which include the seawater electrolyte and the weak acids controlling pH. This core model can then be expanded by incorporating additional chemical components, changing the standard seawater composition and/or broadening the range of temperature and pressure, without compromising its validity. Seven important areas of application are identified: open ocean acidification; micro-nutrient biogeochemistry and geochemical tracers; micro-nutrient behaviour in laboratory studies; water quality in coastal and estuarine waters; cycling of nutrients and trace metals in pore waters; chemical equilibria in hydrothermal systems; brines and salt lakes.

  17. Quality control of radiation counting systems and measurement of minimum detectable activity

    International Nuclear Information System (INIS)

    Song, Byoung Chul; Han, Sung Sim; Kim, Young Bok; Jee, Kwang Yong; Sohn, Se Chul

    2004-01-01

    Various radiation counters have been using to determine radioactivity of radwastes for disposal. A radiation counting system was set up using a radiation detector chosen in this study and its stability was investigated through the periodic determination of background and counting efficiencies in accordance with a quality control program to increase the confidence level. The average background level for the γ-spectrometer was 1.59 cps and the average counting level for the standard sample was 45248 dps within 20 confidence levels. The average alpha background level for the low background α/β counting system was 0.31 cpm and the efficiency for alpha counting was 34.38 %. The average beta background level for the α/β counting system was 1.30 cpm and the efficiency for beta counting was 46.5%. The background level in the region of 3H and 14C for the liquid scintillation counting system was 2.52 and 3.31 cpm and the efficiency for alpha counting was 58.5 and 95.6%, respectively. The minimum detectable activity for the γ-spectrometer was found to be 3.2 Bq/mL and 3.8 Bq/mL for the liquid scintillation counter, and 20.5 and 23.0 Bq/mL, respectively for the α and β counting system

  18. ChronQC: a quality control monitoring system for clinical next generation sequencing.

    Science.gov (United States)

    Tawari, Nilesh R; Seow, Justine Jia Wen; Perumal, Dharuman; Ow, Jack L; Ang, Shimin; Devasia, Arun George; Ng, Pauline C

    2018-05-15

    ChronQC is a quality control (QC) tracking system for clinical implementation of next-generation sequencing (NGS). ChronQC generates time series plots for various QC metrics to allow comparison of current runs to historical runs. ChronQC has multiple features for tracking QC data including Westgard rules for clinical validity, laboratory-defined thresholds and historical observations within a specified time period. Users can record their notes and corrective actions directly onto the plots for long-term recordkeeping. ChronQC facilitates regular monitoring of clinical NGS to enable adherence to high quality clinical standards. ChronQC is freely available on GitHub (https://github.com/nilesh-tawari/ChronQC), Docker (https://hub.docker.com/r/nileshtawari/chronqc/) and the Python Package Index. ChronQC is implemented in Python and runs on all common operating systems (Windows, Linux and Mac OS X). tawari.nilesh@gmail.com or pauline.c.ng@gmail.com. Supplementary data are available at Bioinformatics online.

  19. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems.

    NARCIS (Netherlands)

    Bouwman, R.; Young, K.; Lazzari, B.; Ravaglia, V.; Broeders, M.J.M.; Engen, R. van

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does

  20. Organizing quality control programmes

    International Nuclear Information System (INIS)

    Hjardemaal, O.

    1989-01-01

    When procuring new equipment, performance and safety should be specified, if possible by reference to international standards. Some of the characteristics of the International Electrotechnical Commission (IEC) standard for X-ray generators, in particular the accuracy of the operating data, are described. The quality control tests to be performed after installation comprise acceptance test, status test and constancy test. The first two involve absolute measurements and will be the responsibility of physicists or engineers. Apparently limiting values stipulated by users are a factor of two lower than the limits of the IEC standard. By means of an example it is shown that modern X-ray generators can meet the lower limits of the users without problems. In order to obtain optimum initial quality when procuring new equipment operating data, limiting values must be specified and must be verified by acceptance testing, etc. However, in many countries physicists and engineers are not available for this job. A relatively uncomplicated test object can be used by radiographers for checks on fluoroscopic systems. The findings from such tests in Denmark are compared with other published findings and good agreement is found. Therefore it is proposed that such uncomplicated tests could form the basis for quality evaluation. (author)

  1. Gamma camera computer system quality control for conventional and tomographic use

    International Nuclear Information System (INIS)

    Laird, E.E.; Allan, W.; Williams, E.D.

    1983-01-01

    The proposition that some of the proposed measurements of gamma camera performance parameters for routine quality control are redundant and that only the uniformity requires daily monitoring was examined. To test this proposition, measurements of gamma camera performance were carried out under normal operating conditions and also with the introduction of faults (offset window, offset PM tube). Results for the uniform flood field are presented for non-uniformity, intrinsic spatial resolution, linearity and relative system sensitivity. The response to introduced faults revealed that while the non-uniformity response pattern of the gamma camera was clearly affected, both measurements and qualitative indications of the other performance parameters did not necessarily show any deterioration. (U.K.)

  2. [External quality control system in medical microbiology and parasitology in the Czech Republic].

    Science.gov (United States)

    Slosárek, M; Petrás, P; Kríz, B

    2004-11-01

    The External Quality Control System (EQAS) of laboratory activities in medical microbiology and parasitology was implemented in the Czech Republic in 1993 with coded sera samples for diagnosis of viral hepatitis and bacterial strains for identification distributed to first participating laboratories. The number of sample types reached 31 in 2003 and the number of participating laboratories rised from 79 in 1993 to 421 in 2003. As many as 15.130 samples were distributed to the participating laboratories in 2003. Currently, almost all microbiology and parasitology laboratories in the Czech Republic involved in examination of clinical material participate in the EQAS. Based on the 11-year experience gained with the EQAS in the Czech Republic, the following benefits were observed: higher accuracy of results in different tests, standardisation of methods and the use of most suitable test kits.

  3. [Current situations and problems of quality control for medical imaging display systems].

    Science.gov (United States)

    Shibutani, Takayuki; Setojima, Tsuyoshi; Ueda, Katsumi; Takada, Katsumi; Okuno, Teiichi; Onoguchi, Masahisa; Nakajima, Tadashi; Fujisawa, Ichiro

    2015-04-01

    Diagnostic imaging has been shifted rapidly from film to monitor diagnostic. Consequently, Japan medical imaging and radiological systems industries association (JIRA) have recommended methods of quality control (QC) for medical imaging display systems. However, in spite of its need by majority of people, executing rate is low. The purpose of this study was to validate the problem including check items about QC for medical imaging display systems. We performed acceptance test of medical imaging display monitors based on Japanese engineering standards of radiological apparatus (JESRA) X-0093*A-2005 to 2009, and performed constancy test based on JESRA X-0093*A-2010 from 2010 to 2012. Furthermore, we investigated the cause of trouble and repaired number. Medical imaging display monitors had 23 inappropriate monitors about visual estimation, and all these monitors were not criteria of JESRA about luminance uniformity. Max luminance was significantly lower year-by-year about measurement estimation, and the 29 monitors did not meet the criteria of JESRA about luminance deviation. Repaired number of medical imaging display monitors had 25, and the cause was failure liquid crystal panel. We suggested the problems about medical imaging display systems.

  4. HVAC System Automatic Controls and Indoor Air Quality in Schools. Technical Bulletin.

    Science.gov (United States)

    Wheeler, Arthur E.

    Fans, motors, coils, and other control components enable a heating, ventilating, and air-conditioning (HVAC) system to function smoothly. An explanation of these control components and how they make school HVAC systems work is provided. Different systems may be compared by counting the number of controlled devices that are required. Control…

  5. Parametric Synthesis of Automatic Control System of Industrial Robot Manipulator in Compliance with Requirements of Robust Quality

    Directory of Open Access Journals (Sweden)

    A. A. Nesenchuk

    2004-01-01

    Full Text Available The paper considers an application of a root-locus method for synthesis of dynamic systems with uncertainty that meet the requirements of pre-set quality. This method is used for parametric synthesis of automatic control system of industrial robot manipulator that is used for transportation of engineering products. The synthesis takes place under conditions of substantial changes in inertia moment of robot load. As a result of investigations it is possible to determine range of values of variable parameter that ensures the required quality of control system operation. A system of computer programs has been developed in order to solve the problem.

  6. PQLX: A seismic data quality control system description, applications, and users manual

    Science.gov (United States)

    McNamara, Daniel E.; Boaz, Richard I.

    2011-01-01

    Earthquake Information Center (NEIC), the USGS Albuquerque Seismological Laboratory (ASL), and the Incorporated Research Institutions in Seismology (IRIS) Data Management Center (DMC) for station monitoring and instrument response quality control. The PQLX system is available to the community at large through the U.S. Geological Survey (USGS) (http://ehpm-earthquake.wr.usgs.gov/research/software/pqlx.php) and IRIS (http://www.iris.edu/software/pqlx). Also provided is a fully searchable website for bug reporting and enhancement requests (http://wush.net/bugzilla/PQLX). The first part of this document aims to describe and illustrate some of the features and capabilities of the software. The second part of this document is a detailed users manual that covers installation procedures, system requirements, operations, bug reporting, and software components (Appendix).

  7. Quality assurance in central nuclear power plant control systems. (Status report containing proposed enhancements for KTA rules)

    International Nuclear Information System (INIS)

    Gossner, S.

    1985-01-01

    All enterprises investigated observe the requirements laid down in KTA 1401. In most cases, the quality assurance systems and measures applied even go beyond the requirements of KTA 1401, especially in those enterprises working primarily for export and having to meet foreign quality assurance standards. Quality assurance measures in these enterprises are based primarily on 10 CFR 50, App.B and related rules and standards (e.g. ANSI N 54.2; NUREG 75/087). Internal quality assurance in these enterprises is organized on the basis of graphic flow diagrams which are even presented in the quality assurance manuals. These flow diagrams, in contrast to the German KTA rules, meet the international standards for quality assurance. KTA 1401 requirements not sufficiently met are, e.g. the operator audits with plant producers and unit and equipment producer audits with component producers. The report presents hints for improvements of the quality assurance concept in control systems engineering. (orig./HP) [de

  8. A holistic strategy for quality and safety control of traditional Chinese medicines by the “iVarious” standard system

    Directory of Open Access Journals (Sweden)

    Anzhen Chen

    2017-10-01

    Full Text Available An effective quality control system is the key to ensuring the quality, safety and efficacy of traditional Chinese medicines (TCMs. However, the current quality standard research lacks the top-design and systematic design, mostly based on specific technologies or evaluation methods. To resolve the challenges and questions of quality control of TCMs, a brand-new quality standard system, named “iVarious”, was proposed. The system comprises eight elements in a modular format. Meaning of every element was specifically illustrated via corresponding research instances. Furthermore, frankincense study was taken as an example for demonstrating standards and research process, based on the “iVarious” system. This system highlighted a holistic strategy for effectiveness, security, integrity and systematization of quality and safety control standards of TCMs. The establishment of “iVarious” integrates multi-disciplinary technologies and progressive methods, basis elements and key points of standard construction. The system provides a novel idea and technological demonstration for regulation establishment of TCMs quality standards.

  9. A holistic strategy for quality and safety control of traditional Chinese medicines by the "iVarious" standard system.

    Science.gov (United States)

    Chen, Anzhen; Sun, Lei; Yuan, Hang; Wu, Aiying; Lu, Jingguang; Ma, Shuangcheng

    2017-10-01

    An effective quality control system is the key to ensuring the quality, safety and efficacy of traditional Chinese medicines (TCMs). However, the current quality standard research lacks the top-design and systematic design, mostly based on specific technologies or evaluation methods. To resolve the challenges and questions of quality control of TCMs, a brand-new quality standard system, named "iVarious", was proposed. The system comprises eight elements in a modular format. Meaning of every element was specifically illustrated via corresponding research instances. Furthermore, frankincense study was taken as an example for demonstrating standards and research process, based on the "iVarious" system. This system highlighted a holistic strategy for effectiveness, security, integrity and systematization of quality and safety control standards of TCMs. The establishment of "iVarious" integrates multi-disciplinary technologies and progressive methods, basis elements and key points of standard construction. The system provides a novel idea and technological demonstration for regulation establishment of TCMs quality standards.

  10. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Verdera, E.S.

    1994-01-01

    The quality control of radiopharmaceuticals is based in physics, physics-chemical and biological controls. Between the different controls can be enumerated the following: visual aspect,side, number of particle beams,activity,purity,ph,isotonicity,sterility,radioinmunoessay,toxicity,stability and clinical essay

  11. Active binder content as a factor of the control system of the moulding sand quality

    Directory of Open Access Journals (Sweden)

    J. Jakubski

    2011-01-01

    Full Text Available One of the modern methods of the production optimisation are artificial neural networks. Neural networks are gaining broader and broaderapplication in the foundry industry, among others for controlling melting processes in cupolas and in arc furnaces, for designing castingsand supply systems, for controlling moulding sand processing, for predicting properties of cast alloys or selecting parameters of pressurecastings. An attempt to apply neural networks for controlling the quality of bentonite moulding sands is presented in this paper. This is theassessment method of sands suitability by means of detecting correlations between their individual parameters. The presentedinvestigations were obtained by using the Statistica 9.0 program. The presented investigations were aimed at the selection of the neuralnetwork able to predict the active bentonite content in the moulding sand on the basis of this sand properties such as: permeability,compactibility and the compressive strength. An application of the Statistica program allowed to select automatically the type of networkproper for the representation of dependencies occurring in between the proposed moulding sand parameters. The most advantageousconditions were obtained for the uni-directional multi-layer perception (MLP network. Knowledge of the neural network sensitivity to individual moulding sand parameters, allowed to eliminate not essential ones.

  12. Analyst Tools and Quality Control Software for the ARM Data System

    Energy Technology Data Exchange (ETDEWEB)

    Moore, S.T.

    2004-12-14

    ATK Mission Research develops analyst tools and automated quality control software in order to assist the Atmospheric Radiation Measurement (ARM) Data Quality Office with their data inspection tasks. We have developed a web-based data analysis and visualization tool, called NCVweb, that allows for easy viewing of ARM NetCDF files. NCVweb, along with our library of sharable Interactive Data Language procedures and functions, allows even novice ARM researchers to be productive with ARM data with only minimal effort. We also contribute to the ARM Data Quality Office by analyzing ARM data streams, developing new quality control metrics, new diagnostic plots, and integrating this information into DQ HandS - the Data Quality Health and Status web-based explorer. We have developed several ways to detect outliers in ARM data streams and have written software to run in an automated fashion to flag these outliers.

  13. Neural Network based Control of SG based Standalone Generating System with Energy Storage for Power Quality Enhancement

    Science.gov (United States)

    Nayar, Priya; Singh, Bhim; Mishra, Sukumar

    2017-08-01

    An artificial intelligence based control algorithm is used in solving power quality problems of a diesel engine driven synchronous generator with automatic voltage regulator and governor based standalone system. A voltage source converter integrated with a battery energy storage system is employed to mitigate the power quality problems. An adaptive neural network based signed regressor control algorithm is used for the estimation of the fundamental component of load currents for control of a standalone system with load leveling as an integral feature. The developed model of the system performs accurately under varying load conditions and provides good dynamic response to the step changes in loads. The real time performance is achieved using MATLAB along with simulink/simpower system toolboxes and results adhere to an IEEE-519 standard for power quality enhancement.

  14. Quality Control in construction.

    Science.gov (United States)

    1984-01-01

    behavioral scientists. In 1962, Dr. Kaoru Ishikawa gave shape to the form of training which featured intradepartmental groups of ten or so workers seated...and Japanese circles bears closer scrutiny. 4.3.1 Japanese Ingredients of Quality The founder of quality circles, Dr. Kaoru Ishikawa , gives six...around 51 a table; hence the name Quality Control Circle. 4 Dr. 0 Ishikawa was an engineering professor at Tokyo University, and the circles were

  15. New chromatographic systems for the quality control determination of 99Tcm-tetrofosmin

    International Nuclear Information System (INIS)

    Penglis, S.; Tsopelas, C.

    1999-01-01

    Full text: The manufacturer's method for assessing the radiochemical purity (RCP) of 99 Tc m -tetrofosmin requires the use of a volatile solvent system on silica gel impregnated thin layer chromatography strips, and is a time-consuming procedure (> 15 minutes). A rapid quality control procedure for this product has already been proposed which utilizes miniature Whatman 1 paper strips with ethyl acetate as the mobile phase, where 99 Tc m -tetrofosmin appears at the solvent front (R f 0.9). In our laboratory, this procedure was found to be unreliable, prompting us to develop two new and improved methods to successfully determine the % RCP of 99 Tc m -tetrofosmin. These include: (1) an Amprep anion exchange cartridge with absolute ethanol as the mobile phase; and (2) a miniature Whatman 17 strip with ethyl acetate:acetone [1:9] as the mobile phase. 99 Tc m -tetrofosmin elutes with the solvent, and 99 Tc m O 2 plus 99 Tc m O 4 -remain on the cartridge for the cartridge method. 99 Tc m -tetrofosmin moves with the solvent front (Rf 0.8) and the other 99 Tc m -impurities remain at the origin for the Whatman paper method. The % RCP of 99 Tc m -tetrofosmin (n = 8) by the manufacturer's method was 96.5 ± 1.5%, as compared to the cartridge method (98.0 ± 0.9%) and Whatman paper method (97.3 ± 0.9%) at 0-2 h post-reconstitution. The quality control determinations gave a result in 3 or 5 min for the cartridge or Whatman paper methods respectively. These methods can be used successfully in a dose calibrator for counting, particularly if the total counts are > 1.5 MBq. These new methods were found to be highly reproducible, convenient and rapid for the routine analysis of 99 Tc m -tetrofosmin preparations

  16. Quality Control System for Beer Developed with Monoclonal Antibodies Specific to Barley Lipid Transfer Protein

    Directory of Open Access Journals (Sweden)

    Yukie Murakami-Yamaguchi

    2012-10-01

    Full Text Available Non-specific lipid transfer protein (LTP in barley grain reacted with the IgE in sera drawn from food allergy patients. A sandwich-type of enzyme-linked immunosorbent assay (ELISA was developed with mouse monoclonal antibodies raised against LTP purified with barley flour. This ELISA showed a practical working range of 0.3–3 ng/mL and no cross-reactivity with wheat, adlay and rye. Using this ELISA, LTP was determined in several types of barley-foods, including fermented foods such as malt vinegar, barley-malt miso and beer. LTP content in beer of the same kind was approximately constant, even if manufacturing factory and production days were different. Not only as a factor of foam formation and stability but also as an allergen, controlling and monitoring of LTP in beer should be considered. Taken together, our LTP-detecting ELISA can be proposed as an appropriate system for the quality control of beer.

  17. A Laser-Based Measuring System for Online Quality Control of Car Engine Block

    Directory of Open Access Journals (Sweden)

    Xing-Qiang Li

    2016-11-01

    Full Text Available For online quality control of car engine production, pneumatic measurement instrument plays an unshakeable role in measuring diameters inside engine block because of its portability and high-accuracy. To the limitation of its measuring principle, however, the working space between the pneumatic device and measured surface is too small to require manual operation. This lowers the measuring efficiency and becomes an obstacle to perform automatic measurement. In this article, a high-speed, automatic measuring system is proposed to take the place of pneumatic devices by using a laser-based measuring unit. The measuring unit is considered as a set of several measuring modules, where each of them acts like a single bore gauge and is made of four laser triangulation sensors (LTSs, which are installed on different positions and in opposite directions. The spatial relationship among these LTSs was calibrated before measurements. Sampling points from measured shaft holes can be collected by the measuring unit. A unified mathematical model was established for both calibration and measurement. Based on the established model, the relative pose between the measuring unit and measured workpiece does not impact the measuring accuracy. This frees the measuring unit from accurate positioning or adjustment, and makes it possible to realize fast and automatic measurement. The proposed system and method were finally validated by experiments.

  18. Protocol for the quality control systems of electronic portal imaging used in verification of radiotherapy treatment

    International Nuclear Information System (INIS)

    Silvestre, Ileana; Alfonso, Rodolfo; Garcia, Fernando

    2009-01-01

    Following the approach of quality control of radiotherapy equipment, conceived in the IAEA TECDOC-1151, we analyzed the different tests must be to an EPID to guarantee levels of accuracy required in the administration of radiation treatments, including the study of the impact of different parameters, geometric and dosimetric imaging, involved in the process. Established the types and frequency of checks, as well as procedures for their implementation, the allowable tolerances set of values records and forms for recording . Was carried out assessment protocol in various services based on amorphous silicon EPID for its applicability and scope. Was designed and validated in clinical practice protocol for EPID quality control, demonstrating its applicability with a minimum of material and human resources. It We concluded that with proper and systematic quality control program, tests including dosimetry, the EPID can provide valuable information about physico-beam dosimetry, and ensure adequate accuracy geometric in the patient's location. (author)

  19. Towards evidence-based, quality-controlled health promotion: the Dutch recognition system for health promotion interventions.

    NARCIS (Netherlands)

    Brug, J.; Dale, D. van; Lanting, L.; Kremers, S.; Veenhof, C.; Leurs, M.; Yperen, T. van; Kok, G.

    2010-01-01

    Registration or recognition systems for best-practice health promotion interventions may contribute to better quality assurance and control in health promotion practice. In the Netherlands, such a system has been developed and is being implemented aiming to provide policy makers and professionals

  20. Stability of two measuring systems used in quality control of mammography; Estabilidade de dois sistemas de medicao utilizados no controle de qualidade de mamografos

    Energy Technology Data Exchange (ETDEWEB)

    Barreira, Jacqueline Sales; Vivolo, Vitor, E-mail: jacsales@usp.br [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2014-07-01

    The use of X-Rays for diagnosis is very important for medicine, including mammographic exam. A quality control program is necessary to control the radiation systems performance. The objective of this paper is evaluation of stability of measurement working system and measurement standard system, collecting meters of charge and dose using one source of Strontium 90 (Sr-90). The results of this test are very important to determine if the instruments are calibrated for use in quality control program for a mammography equipment. (author)

  1. [Quality control in herbal supplements].

    Science.gov (United States)

    Oelker, Luisa

    2005-01-01

    Quality and safety of food and herbal supplements are the result of a whole of different elements as good manufacturing practice and process control. The process control must be active and able to individuate and correct all possible hazards. The main and most utilized instrument is the hazard analysis critical control point (HACCP) system the correct application of which can guarantee the safety of the product. Herbal supplements need, in addition to standard quality control, a set of checks to assure the harmlessness and safety of the plants used.

  2. On the Use of Information Quality in Stochastic Networked Control Systems

    DEFF Research Database (Denmark)

    Olsen, Rasmus Løvenstein; Madsen, Jacob Theilgaard; Rasmussen, Jakob Gulddahl

    2017-01-01

    Networked control is challenged by stochastic delays that are caused by the communication networks as well as by the approach taken to exchange information about system state and set-points. Combined with stochastic changing information, there is a probability that information at the controller....... This is first analyzed in simulation models for the example system of a wind-farm controller. As simulation analysis is subject to stochastic variability and requires large computational effort, the paper develops a Markov model of a simplified networked control system and uses numerical results from the Markov...... is not matching the true system observation, which we call mismatch probability (mmPr). The hypothesis is that the optimization of certain parameters of networked control systems targeting mmPr is equivalent to the optimization targeting control performance, while the former is practically much easier to conduct...

  3. The MAGTAG-system and market-oriented quality control: Possibilities in the Danish beef sector

    DEFF Research Database (Denmark)

    Plichta, Kirsten; Andersen, Esben Sloth

    1995-01-01

    and quality grades in the retail market for beef. * The advantage of using the MAGTAG-system for developing new credence characteristics depends on consumer preferences for such attributes and on the retailers' ability to standardize the quality of ordinary as well as ecological or 'ethical' meat. Retailers...... and slaughterers did not believe that the majority of consumers valued the ecological and ethical attributes enough to be willing to pay extra for these attributes....

  4. Reactor Systems Technology Division code development and configuration/quality control procedures

    International Nuclear Information System (INIS)

    Johnson, E.C.

    1985-06-01

    Procedures are prescribed for executing a code development task and implementing the resulting coding in an official version of a computer code. The responsibilities of the project manager, development staff members, and the Code Configuration/Quality Control Group are defined. Examples of forms, logs, computer job control language, and suggested outlines for reports associated with software production and implementation are included in Appendix A. 1 raf., 2 figs

  5. The information system of learning quality control in higher education institutions: achievements and problems of European universities

    Directory of Open Access Journals (Sweden)

    Orekhova Elena

    2016-01-01

    Full Text Available The article deals with the main trends in the development of the system of learning quality control connected with the European integration of higher education and the democratization of education. The authors analyze the state of information systems of learning quality control existing in European higher education and identify their strong and weak points. The authors show that in the learning process universities actively use innovative analytic methods as well as modern means of collecting, storing and transferring information that ensure the successful management of such a complex object as the university of the 21st century.

  6. Quality control of dosemeters

    International Nuclear Information System (INIS)

    Mendes, L.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are acomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintilation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (Author) [pt

  7. Multi-scale optical metrology for the quality control of polymer microfluidic systems

    DEFF Research Database (Denmark)

    Tosello, Guido; Marinello, Francesco; Hansen, Hans Nørgaard

    2009-01-01

    Micro injection moulding is a replication technology enabling large scale production of polymer-based micro products. To this respect, optical measuring technologies were selected to perform the quality control of a polymer micro-component: an optical coordinate measuring machine (CMM) and a white...

  8. Development and experience of quality control methods for digital breast tomosynthesis systems.

    Science.gov (United States)

    Strudley, Cecilia J; Young, Kenneth C; Looney, Padraig; Gilbert, Fiona J

    2015-01-01

    To develop tomosynthesis quality control (QC) test methods and use them alongside established two-dimensional (2D) QC tests to measure the performance of digital breast tomosynthesis (DBT) systems used in a comparative trial with 2D mammography. DBT QC protocols and associated analysis were developed, incorporating adaptions of some 2D tests as well as some novel tests. The tomosynthesis tests were: mean glandular dose to the standard breast model; contrast-to-noise ratio in reconstructed focal planes; geometric distortion; artefact spread; threshold contrast detail detection in reconstructed focal planes, alignment of the X-ray beam to the reconstructed image and missed tissue; reproducibility of the tomosynthesis exposure; and homogeneity of the reconstructed focal planes. Summaries of results from the tomosynthesis QC tests are presented together with some 2D results for comparison. The tomosynthesis QC tests and analysis methods developed were successfully applied. The lessons learnt, which are detailed in the Discussion section, may be helpful to others embarking on DBT QC programmes. DBT performance test equipment and analysis methods have been developed. The experience gained has contributed to the subsequent drafting of DBT QC protocols in the UK and Europe.

  9. Compartmentalized Regulation of Parkin-Mediated Mitochondrial Quality Control in the Drosophila Nervous System In Vivo

    Science.gov (United States)

    Sung, Hyun; Tandarich, Lauren C.; Nguyen, Kenny

    2016-01-01

    In neurons, the normal distribution and selective removal of mitochondria are considered essential for maintaining the functions of the large asymmetric cell and its diverse compartments. Parkin, a E3 ubiquitin ligase associated with familial Parkinson's disease, has been implicated in mitochondrial dynamics and removal in cells including neurons. However, it is not clear how Parkin functions in mitochondrial turnover in vivo, or whether Parkin-dependent events of the mitochondrial life cycle occur in all neuronal compartments. Here, using the live Drosophila nervous system, we investigated the involvement of Parkin in mitochondrial dynamics, distribution, morphology, and removal. Contrary to our expectations, we found that Parkin-deficient animals do not accumulate senescent mitochondria in their motor axons or neuromuscular junctions; instead, they contain far fewer axonal mitochondria, and these displayed normal motility behavior, morphology, and metabolic state. However, the loss of Parkin did produce abnormal tubular and reticular mitochondria restricted to the motor cell bodies. In addition, in contrast to drug-treated, immortalized cells in vitro, mature motor neurons rarely displayed Parkin-dependent mitophagy. These data indicate that the cell body is the focus of Parkin-dependent mitochondrial quality control in neurons, and argue that a selection process allows only healthy mitochondria to pass from cell bodies to axons, perhaps to limit the impact of mitochondrial dysfunction. SIGNIFICANCE STATEMENT Parkin has been proposed to police mitochondrial fidelity by binding to dysfunctional mitochondria via PTEN (phosphatase and tensin homolog)-induced putative kinase 1 (PINK1) and targeting them for autophagic degradation. However, it is unknown whether and how the PINK1/Parkin pathway regulates the mitochondrial life cycle in neurons in vivo. Using Drosophila motor neurons, we show that parkin disruption generates an abnormal mitochondrial network in cell

  10. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  11. Quality control as a way to find out doses as low as reasonably practicable in mammography systems

    International Nuclear Information System (INIS)

    Hwang, S.F.; Nogueira, M.S.; Peixoto, J.E.; Paraguay, Y.V.

    2008-01-01

    The breast cancer is the most common neoplasm amongst women. Mammography is an essential tool for diagnosis and early detection of this disease. In order to guarantee the effectiveness of the diagnosis taking into account the patient radiation safety, it is mandatory to perform the quality control tests of the mammographic equipment. The main objective of this work has been to evaluate the relationship between the image quality and the total performance of the medical equipment. Primary data were collected from several radiological facilities during the quality control inspections performed by the local regulatory authorities of the Brazilian health, the National Commission of Nuclear Energy and the Brazilian College of Radiology. The main important functioning parameters were evaluated as well as the image quality using the simulator 'phantom mama'. In spite of the fact that high quality images could suggest delivering large radiation doses to patients it has been demonstrated that it is possible to acquire images with a good quality for clinical diagnosis without delivering high doses if the system is working properly. It has been concluded that following an optimized quality control program could avoid the complex dosimetric studies to guarantee good images quality. (author)

  12. System Proposal for Mass Transit Service Quality Control Based on GPS Data.

    Science.gov (United States)

    Padrón, Gabino; Cristóbal, Teresa; Alayón, Francisco; Quesada-Arencibia, Alexis; García, Carmelo R

    2017-06-16

    Quality is an essential aspect of public transport. In the case of regular public passenger transport by road, punctuality and regularity are criteria used to assess quality of service. Calculating metrics related to these criteria continuously over time and comprehensively across the entire transport network requires the handling of large amounts of data. This article describes a system for continuously and comprehensively monitoring punctuality and regularity. The system uses location data acquired continuously in the vehicles and automatically transferred for analysis. These data are processed intelligently by elements that are commonly used by transport operators: GPS-based tracking system, onboard computer and wireless networks for mobile data communications. The system was tested on a transport company, for which we measured the punctuality of one of the routes that it operates; the results are presented in this article.

  13. Photovoltaic Impact Assessment of Smart Inverter Volt-VAR Control on Distribution System Conservation Voltage Reduction and Power Quality

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Fei [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nagarajan, Adarsh [National Renewable Energy Lab. (NREL), Golden, CO (United States); Chakraborty, Sudipta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Baggu, Murali [National Renewable Energy Lab. (NREL), Golden, CO (United States); Nguyen, Andu [SolarCity, San Mateo, CA (United States); Walinga, Sarah [SolarCity, San Mateo, CA (United States); McCarty, Michael [SolarCity, San Mateo, CA (United States); Bell, Frances [SolarCity, San Mateo, CA (United States)

    2016-12-01

    This report presents an impact assessment study of distributed photovoltaic (PV) with smart inverter Volt-VAR control on conservation voltage reduction (CVR) energy savings and distribution system power quality. CVR is a methodology of flattening and lowering a distribution system voltage profile in order to conserve energy. Traditional CVR relies on operating utility voltage regulators and switched capacitors. However, with the increased penetration of distributed PV systems, smart inverters provide the new opportunity to control local voltage and power factor by regulating the reactive power output, leading to a potential increase in CVR energy savings. This report proposes a methodology to implement CVR scheme by operating voltage regulators, capacitors, and autonomous smart inverter Volt-VAR control in order to achieve increased CVR benefit. Power quality is an important consideration when operating a distribution system, especially when implementing CVR. It is easy to measure the individual components that make up power quality, but a comprehensive method to incorporate all of these values into a single score has yet to be undertaken. As a result, this report proposes a power quality scoring mechanism to measure the relative power quality of distribution systems using a single number, which is aptly named the 'power quality score' (PQS). Both the CVR and PQS methodologies were applied to two distribution system models, one obtained from the Hawaiian Electric Company (HECO) and another obtained from Pacific Gas and Electric (PG&E). These two models were converted to the OpenDSS platform using previous model conversion tools that were developed by NREL. Multiple scenarios including various PV penetration levels and smart inverter densities were simulated to analyze the impact of smart inverter Volt-VAR support on CVR energy savings and feeder power quality. In order to analyze the CVR benefit and PQS, an annual simulation was conducted for each

  14. Ocean Data Quality Control

    Science.gov (United States)

    2011-11-18

    the aero- sol at the coincident time and location of the satellite SST retrievals. This informa- tion is available in the daytime for the anti-solar...are of the same form, such as probabilities or standard normal deviates. A quality control decision-making algorithm in use at the U.S. Navy oceano

  15. Quality management systems in radiology

    Directory of Open Access Journals (Sweden)

    Geoffrey K. Korir

    2013-08-01

    Objective: To assess the level of quality management systems in X-ray medical facilities in Kenya. Methods: Quality management inspection, quality control performance tests and patient radiation exposure were assessed in 54 representative X-ray medical facilities. Additionally, a survey of X-ray examination frequency was conducted in 140 hospitals across the country. Results: The overall findings placed the country’s X-ray imaging quality management systems at 61±3% out of a possible 100%. The most and the least quality assurance performance indicators were general radiography X-ray equipment quality control tests at 88±4%, and the interventional cardiology adult examinations below diagnostic reference level at 25±1%, respectively. Conclusions: The study used a systematic evidence-based approach for the assessment of national quality management systems in radiological practice in clinical application, technical conduct of the procedure, image quality criteria, and patient characteristics as part of the quality management programme.

  16. Water Quality Control for Shrimp Pond Using Adaptive Neuro Fuzzy Inference System : The First Project

    Science.gov (United States)

    Umam, F.; Budiarto, H.

    2018-01-01

    Shrimp farming becomes the main commodity of society in Madura Island East Java Indonesia. Because of Madura island has a very extreme weather, farmers have difficulty in keeping the balance of pond water. As a consequence of this condition, there are some farmers experienced losses. In this study an adaptive control system was developed using ANFIS method to control pH balance (7.5-8.5), Temperature (25-31°C), water level (70-120 cm) and Dissolved Oxygen (4-7,5 ppm). Each parameter (pH, temperature, level and DO) is controlled separately but can work together. The output of the control system is in the form of pump activation which provides the antidote to the imbalance that occurs in pond water. The system is built with two modes at once, which are automatic mode and manual mode. The manual control interface based on android which is easy to use.

  17. Implementation of the program of quality control of the system on-board imager of varian: initial assessment

    International Nuclear Information System (INIS)

    Ortega Martin, I.; Ruiz Morales, C.; Lopez Sanchez, F.; Tobarra Gonzalez, B. M.

    2013-01-01

    This work aims to present evidence that are part of our quality control system on-board Imager of Varian, elaborated from recommendations and national and international protocols, as well as a first assessment of the results obtained to date. (Author)

  18. VGI QUALITY CONTROL

    Directory of Open Access Journals (Sweden)

    C. C. Fonte

    2015-08-01

    Full Text Available This paper presents a framework for considering quality control of volunteered geographic information (VGI. Different issues need to be considered during the conception, acquisition and post-acquisition phases of VGI creation. This includes items such as collecting metadata on the volunteer, providing suitable training, giving corrective feedback during the mapping process and use of control data, among others. Two examples of VGI data collection are then considered with respect to this quality control framework, i.e. VGI data collection by National Mapping Agencies and by the most recent Geo-Wiki tool, a game called Cropland Capture. Although good practices are beginning to emerge, there is still the need for the development and sharing of best practice, especially if VGI is to be integrated with authoritative map products or used for calibration and/or validation of land cover in the future.

  19. Design and quality assurance of control and instrumentation systems, licensing practice in Austria

    International Nuclear Information System (INIS)

    Fasko, Peter.

    1978-01-01

    The practicised way how licensing of control and instrumentation systems is performed in Austria, is related. As there is no national regulations in Austria for licensing nuclear power plants, it tries to adopt international regulations for its own purpose. (author)

  20. Quality of Life, Health, and Sleep of Air Traffic Controllers with Different Shift Systems.

    Science.gov (United States)

    Sonati, Jaqueline; De Martino, Milva; Vilarta, Roberto; Maciel, Érika; Moreira, Edméia; Sanchez, Fernando; De Martino, Gustavo; Sonati, Renato

    2015-10-01

    Air traffic controllers (ATC) work shifts and their work schedules vary according to the characteristics of each airport. The human body adapts to shiftwork differently. These adjustments affect the health-disease process, predisposing ATC to risk conditions associated with sleep deprivation and lack of night sleep, which can lead to conditions such as cardiovascular diseases, mood disorders, anxiety, and obesity. This study investigated the characteristics of health, sleep, and quality of life of ATC exposed to 8-h alternate work shifts and 6-h rotational work shifts. The study was cross-sectional with convenience samples consisting of 84 ATC from two international airports in Brazil. We applied questionnaires to collect data about socioeconomic conditions, quality of life, sleep, and physical activity levels. We also collected health data regarding nutritional status, body composition, and blood pressure. We analyzed the differences between ATC from the two airports considering the variables of sleep, quality of life, and health. Differences were found between the groups in terms of body fat percentage (30.7% and 27.8%), scores of overall quality of life (56.2 and 68), concentration (3.37 and 3.96), energy (3.12 and 3.62), and sleep time on working days (5:20 h and 6:15 h). ATC under 8-h alternate shifts showed lower scores for quality of life, higher body fat, and less sleep time on working days, which characterizes inadequate shiftwork for this population.

  1. Procedure for making mannequins tailor for image quality control of PET by 3D printing systems

    International Nuclear Information System (INIS)

    Collado Chamorro, P. M.; Saez Beltran, F.; Diaz Pascual, V.; Benito Bejarado, M. A.; Sanz Freire, C. J.; Lopo Casqueiro, N.; Gonzalez Fernandez, M. P.; Lopez de Gamarra, M. S.

    2015-01-01

    There is a software free both for be the processes of modeling of the objects 3D to split of medical images, as for convert said modeling to file ready for be read and executed by the 3D printers (sequence or slicer). This lets make mannequins of Control of quality with a investment minimum. In this work is built a mannequin of brain refillable to measurement for be used in studies PET. (Author)

  2. Analysis of the acceptance procedure and quality control a virtual simulation system

    International Nuclear Information System (INIS)

    Gonzalez Ruiz, C.; Pedrero de Aristizabal, D.; Jimenez Rojas, R.; Garcia Hernandez, M. J.; Ruiz Galan, G.; Ayala Lazaro, R.; Garcia Marcos, R.

    2011-01-01

    Acceptance has been made, determining the reference state, commissioning and implementation of control protocol virtual simulation system consists of an image acquisition unit of computerized tomography (CT), an independent external location laser locator and a simulation module associated with the existing scheduler for clinical dosimetry in radiotherapy. This paper summarizes the path followed in this process, together with the established procedure for periodic monitoring and analysis system of the results obtained in the two years of clinical and control.

  3. Comparative evaluation of image quality of various digital radiology systems and quality control and optimization of radiation protection at the Amiens university hospital

    International Nuclear Information System (INIS)

    Foro, Saturnin Didace L.

    2004-01-01

    This study was centered on two axes: the first is the comparative evaluation of image quality of various numerical radiology system, the second is the quality control and the optimization of protection against radiation. The publication of directive 97/43 Euratom from council of June 30, 1997 and consequently, the decree of February 12, 2004 founded a strict lawful framework that is engaged to respect the University Hospital of Amiens by the installation of a operational dosimetry system and the application of February 12, 2004 decree. (author) [fr

  4. Ozonation control and effects of ozone on water quality in recirculating aquaculture systems

    DEFF Research Database (Denmark)

    Spiliotopoulou, Aikaterini; Rojas-Tirado, Paula Andrea; Chetri, Ravi K.

    2018-01-01

    To address the undesired effect of chemotherapeutants in aquaculture, ozone has been suggested as an alternative to improve water quality. To ensure safe and robust treatment, it is vital to define the ozone demand and ozone kinetics of the specific water matrix to avoid ozone overdose. Different...... ozone dosages were applied to water in freshwater recirculating aquaculture systems (RAS). Experiments were performed to investigate ozone kinetics and demand, and to evaluate the effects on the water quality, particularly in relation to fluorescent organic matter. This study aimed at predicting...... a suitable ozone dosage for water treatment based on daily ozone demand via laboratory studies. These ozone dosages will be eventually applied and maintained at these levels in pilot-scale RAS to verify predictions. Selected water quality parameters were measured, including natural fluorescence and organic...

  5. Digital test objects (D.T.O.) for treatment planning systems quality control in external beam radiotherapy

    International Nuclear Information System (INIS)

    Denis, E.

    2008-04-01

    This work presents the conception and implementation of new automatic and quantitative quality assessment methods for geometric treatment planning in external radiotherapy. Treatment planning Systems (T.P.S.) quality control is mandatory in France and in the world because of encountered risks but the physical tools recommended to lead this quality control are not adapted to the situation. We present a new methodology for control quality based on the definition of Digital Test Objects (D.T.O.) that are directly introduced in the T.P.S. without acquisition device. These D.T.O. are consistently defined in a continuous and discrete modes. The T.P.S. responses to input D.T.O. are compared to theoretical results thanks to figures of merit specifically designed for each elementary control. The tests we carried out during this study allow to validate our solutions for the quality assessment of the auto-contouring, auto-margining, isocenter computation, collimator conformation and digitally reconstructed radiograph generation tools, as well as our solutions for marker positioning, collimator and displayed bean rotation, incidence, divergence and dimensions. Quality assessment solutions we propose are then fast and effective (no acquisition by the device, reduced manipulations), and more precise thanks to the continuous-discrete equivalence realized at the beginning of the modelling

  6. A new verification film system for routine quality control of radiation fields: Kodak EC-L.

    Science.gov (United States)

    Hermann, A; Bratengeier, K; Priske, A; Flentje, M

    2000-06-01

    The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged "good", only 18% were classified "moderate" or "poor" 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be "good". The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated.

  7. A new verification film system for routine quality control of radiation fields: Kodak EC-L

    International Nuclear Information System (INIS)

    Hermann, A.; Bratengeier, K.; Priske, A.; Flentje, M.

    2000-01-01

    Background: The use of modern irradiation techniques requires better verification films for determining set-up deviations and patient movements during the course of radiation treatment. This is an investigation of the image quality and time requirement of a new verification film system compared to a conventional portal film system. Material and Methods: For conventional verifications we used Agfa Curix HT 1000 films which were compared to the new Kodak EC-L film system. 344 Agfa Curix HT 1000 and 381 Kodak EC-L portal films of different tumor sites (prostate, rectum, head and neck) were visually judged on a light box by 2 experienced physicians. Subjective judgement of image quality, masking of films and time requirement were checked. Results: In this investigation 68% of 175 Kodak EC-L ap/pa-films were judged 'good', only 18% were classified 'moderate' or 'poor' 14%, but only 22% of 173 conventional ap/pa verification films (Agfa Curix HT 1000) were judged to be 'good'. Conclusions: The image quality, detail perception and time required for film inspection of the new Kodak EC-L film system was significantly improved when compared with standard portal films. They could be read more accurately and the detection of set-up deviation was facilitated. (orig.) [de

  8. 14 CFR 21.139 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Quality control. 21.139 Section 21.139... PROCEDURES FOR PRODUCTS AND PARTS Production Certificates § 21.139 Quality control. The applicant must show that he has established and can maintain a quality control system for any product, for which he...

  9. Quality control of imaging devices

    International Nuclear Information System (INIS)

    Soni, P.S.

    1992-01-01

    Quality assurance in nuclear medicine refers collectively to all aspects of a nuclear medicine service. It would include patient scheduling, radiopharmaceutical preparation and dispensing, radiation protection of patients, staff and general public, preventive maintenance and the care of instruments, methodology, data interpretation and records keeping, and many other small things which contribute directly or indirectly to the overall quality of a nuclear medicine service in a hospital. Quality Control, on the other hand, refers to a signal component of the system and is usually applied in relation to a specific instrument and its performance

  10. Quality control of intelligence research

    International Nuclear Information System (INIS)

    Lu Yan; Xin Pingping; Wu Jian

    2014-01-01

    Quality control of intelligence research is the core issue of intelligence management, is a problem in study of information science This paper focuses on the performance of intelligence to explain the significance of intelligence research quality control. In summing up the results of the study on the basis of the analysis, discusses quality control methods in intelligence research, introduces the experience of foreign intelligence research quality control, proposes some recommendations to improve quality control in intelligence research. (authors)

  11. Verifying Quality of Service of ARCnet Based ATOMOS Communication System for Integrated Ship Control

    DEFF Research Database (Denmark)

    Nielsen, N.N.; Nielsen, Jens Frederik Dalsgaard; Schiøler, Henrik

    point) layer. An important characteristic of the communication system is that the functionality and timing must be verifiable in order to satisfy requirements from classification companies like Lloyds and Norsk Veritas. By including Service Categories, Traffic Descriptors and Quality of Service concepts......As part of the ATOMOS project (Funded by EU, DG VII) a reliable communication system with predictable behaviour has been designed. The selected solution is a network based on redundant ARCnet segments extended with an EN50170 compliant fieldbus based layer on top of an ARCnet SAP (service access...

  12. Verifying Quality of Service of ARCnet Based ATOMOS Communication System for Integrated Ship Control

    DEFF Research Database (Denmark)

    Nielsen, N.N.; Nielsen, Jens Frederik Dalsgaard; Schiøler, Henrik

    1999-01-01

    point) layer. An important characteristic of the communication system is that the functionality and timing must be verifiable in order to satisfy requirements from classification companies like Lloyds and Norsk Veritas. By including Service Categories, Traffic Descriptors and Quality of Service concepts......As part of the ATOMOS project (Funded by EU, DG VII) a reliable communication system with predictable behaviour has been designed. The selected solution is a network based on redundant ARCnet segments extended with an EN50170 compliant fieldbus based layer on top of an ARCnet SAP (service access...

  13. Quality Systems Implementation in the Pharmaceutical Industry

    African Journals Online (AJOL)

    Nafiisah

    quality standards imposed on local pharmaceutical manufacturers. Keywords: Quality/ .... GMP is concerned with both production and quality control. It is aimed ... in the European pharmaceutical industry in designing their quality systems:.

  14. Effect of chemical and mechanical weed control on cassava yield, soil quality and erosion under cassava cropping system

    Science.gov (United States)

    Islami, Titiek; Wisnubroto, Erwin; Utomo, Wani

    2016-04-01

    Three years field experiments were conducted to study the effect of chemical and mechanical weed control on soil quality and erosion under cassava cropping system. The experiment were conducted at University Brawijaya field experimental station, Jatikerto, Malang, Indonesia. The experiments were carried out from 2011 - 2014. The treatments consist of three cropping system (cassava mono culture; cassava + maize intercropping and cassava + peanut intercropping), and two weed control method (chemical and mechanical methods). The experimental result showed that the yield of cassava first year and second year did not influenced by weed control method and cropping system. However, the third year yield of cassava was influence by weed control method and cropping system. The cassava yield planted in cassava + maize intercropping system with chemical weed control methods was only 24 t/ha, which lower compared to other treatments, even with that of the same cropping system used mechanical weed control. The highest cassava yield in third year was obtained by cassava + peanuts cropping system with mechanical weed control method. After three years experiment, the soil of cassava monoculture system with chemical weed control method possessed the lowest soil organic matter, and soil aggregate stability. During three years of cropping soil erosion in chemical weed control method, especially on cassava monoculture, was higher compared to mechanical weed control method. The soil loss from chemical control method were 40 t/ha, 44 t/ha and 54 t/ha for the first, second and third year crop. The soil loss from mechanical weed control method for the same years was: 36 t/ha, 36 t/ha and 38 t/ha. Key words: herbicide, intercropping, soil organic matter, aggregate stability.

  15. The need for a formalised system of Quality Control for environmental policy-science.

    Science.gov (United States)

    Larcombe, Piers; Ridd, Peter

    2018-01-01

    Research science used to inform public policy decisions, herein defined as "Policy-Science", is rarely subjected to rigorous checking, testing and replication. Studies of biomedical and other sciences indicate that a considerable fraction of published peer-reviewed scientific literature, perhaps half, has significant flaws. To demonstrate the potential failings of the present approaches to scientific Quality Control (QC), we describe examples of science associated with perceived threats to the Great Barrier Reef (GBR), Australia. There appears a serious risk of efforts to improve the health of the GBR being directed inefficiently and/or away from the more serious threats. We suggest the need for a new organisation to undertake quality reviews and audits of important scientific results that underpin government spending decisions on the environment. Logically, such a body could also examine policy science in other key areas where governments rely heavily upon scientific results, such as education, health and criminology. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Chemical Quality Control on Water Produced from WFI System at Medical Technology Division, Nuclear Malaysia

    International Nuclear Information System (INIS)

    Muhammad Hanaffi Mohd Mokhtar; Norhafizah Othman; Muhamad Syazwan Zulkifli

    2015-01-01

    Water for Injection (WFI) used in production of Technetium-99m (Tc-99m) bound to stringent specifications in order to comply with Good Manufacturing Practice (GMP) requirements. The WFI should meet British Pharmacopoeia (BP) and United States Pharmacopoeia (USP) grade specifications. The goal of the study is to test the WFI system whether it is running optimally and operating normally after undergo some repairs and maintenance s. Physical appearance, pH, total organic carbon and conductivity test is done in order to evaluate the water quality which consequently implies indirectly the condition of the water system. Results have shown that purified water from sampling point 4 and WFI from sampling point 20 indirectly indicate possible problems in the water system. Overall the WFI system running normally and optimally except for sampling point 4 and 20 which need further investigation. (author)

  17. Research and realization of ten-print data quality control techniques for imperial scale automated fingerprint identification system

    Directory of Open Access Journals (Sweden)

    Qian Wang

    2017-01-01

    Full Text Available As the first individualization-information processing equipment put into practical service worldwide, Automated Fingerprint Identification System (AFIS has always been regarded as the first choice in individualization of criminal suspects or those who died in mass disasters. By integrating data within the existing regional large-scale AFIS database, many countries are constructing an ultra large state-of-the-art AFIS (or Imperial Scale AFIS system. Therefore, it is very important to develop a series of ten-print data quality controlling process for this system of this type, which would insure a substantial matching efficiency, as the pouring data come into this imperial scale being. As the image quality of ten-print data is closely relevant to AFIS matching proficiency, a lot of police departments have allocated huge amount of human and financial resources over this issue by carrying out manual verification works for years. Unfortunately, quality control method above is always proved to be inadequate because it is an astronomical task involved, in which it has always been problematic and less affiant for potential errors. Hence, we will implement quality control in the above procedure with supplementary-acquisition effect caused by the delay of feedback instructions sent from the human verification teams. In this article, a series of fingerprint image quality supervising techniques has been put forward, which makes it possible for computer programs to supervise the ten-print image quality in real-time and more accurate manner as substitute for traditional manual verifications. Besides its prominent advantages in the human and financial expenditures, it has also been proved to obviously improve the image quality of the AFIS ten-print database, which leads up to a dramatic improvement in the AFIS-matching accuracy as well.

  18. Cross-Calibration of Two Automatic Quality Control Systems for the CMS ECAL Crystals

    CERN Document Server

    Auffray, Etiennette; Chevenier, Guy; Lecoq, Paul; Perez-Prado, P; Schneegans, Marc; Sempere-Roldan, P

    2003-01-01

    The barrel part of the CMS electromagnetic calorimeter consists of about 60000 PWO crystals and will be assembled in two Regional Centers, nearby Rome and at CERN. Two automatic machines have been designed to check the crystal quality before assembly. The main crystal characteristics are compared to a set of specifications included in the contract with the crystal producers. The stability and intercalibration between the two is a fundamental issue, which has to be controlled during the whole construction phase. This paper describes the checks that were made in order to cross calibrate the measurements and to guarantee a proper selection of crystals for the detector.

  19. Enhanced job control language procedures for the SIMSYS2D two-dimensional water-quality simulation system

    Science.gov (United States)

    Karavitis, G.A.

    1984-01-01

    The SIMSYS2D two-dimensional water-quality simulation system is a large-scale digital modeling software system used to simulate flow and transport of solutes in freshwater and estuarine environments. Due to the size, processing requirements, and complexity of the system, there is a need to easily move the system and its associated files between computer sites when required. A series of job control language (JCL) procedures was written to allow transferability between IBM and IBM-compatible computers. (USGS)

  20. Quality control of a kV cone beam computed tomography imaging system

    International Nuclear Information System (INIS)

    Marguet, M.; Bodez, V.

    2009-01-01

    Purpose: This work presents the introduction of a quality assurance program for the On-Board Imager (O.B.I., Varian) kV cone beam computed tomography (kV C.B.C.T.) system, together with the results of 1 year monthly testing. Materials and methods: Firstly the geometric precision and stability of the equipment and of the associated software were evaluated using the Marker phantom. The coincidence of the accelerator isocenter and the imager isocenter was verified as well as the accuracy of the registration of kV cone beam computed tomography (kV C.B.C.T.) with reference CT images. Then, the kV C.B.C.T. image quality was evaluated using the Catphan 504 phantom and ArtiScan software (Aquilab) for both full-fan (F.F.) and half-fan (H.F.) imaging modes. Results: The kV C.B.C.T. isocenter and image registration with correction of the table position were found to be within a tolerance of 2.0 mm. Concerning the kV C.B.C.T. image quality, image noise and uniformity, the Hounsfield units (HU) stability and linearity, geometric distortion and high contrast resolution were all found to be within the manufacturer's recommendations for both F.F. and H.F. modes. However, the low contrast resolution for the HF mode did not meet the manufacturer's specifications. Conclusion: The quality assurance tests introduced have defined the initial system characteristics and their evolution during a period of 1 year, demonstrating the stability of the O.B.I.. (authors)

  1. Quality control of system of imaging for rectal ultrasound for implants seed prostate low rate

    International Nuclear Information System (INIS)

    Luquero Llopis, N.; Ferrer Gracia, C.; Huertas Martinez, C.; Huerga Cabrerizo, C.; Corredoira Silva, E.; Serrada Hierro, A.

    2013-01-01

    In this work, the objective is the evaluation of the image system used in implants of prostate of low rate held at our hospital, for maximum control on the placement of the seeds in the patient and therefore carried out dosimetry. (Author)

  2. Modulation of Protein Quality Control Systems as Novel Mechanisms Underlying Functionality of Food Phytochemicals

    Directory of Open Access Journals (Sweden)

    Kohta Ohnishi

    2013-10-01

    Full Text Available Background: Phytochemicals are secondary metabolites of plants that are produced for their defense against environmental stresses, such as polyphenols, which are considered to play a major role in protection against ultraviolet (UV light-induced oxidative damage, as well as anti-fungal and anti-microbial activities. In addition, there is a great body of evidence showing that phytochemicals exhibit a wide array of physiological activities in humans. Accumulated data show that the bioavailability of most, if not all, phytochemicals is quite poor and their substantial biotransformation after ingestion has also been noted. Thus, they are characterized as non-nutritive xenobiotics in animals, and the question of why phytochemicals, which are produced for plant self-defense, have beneficial effects in humans is quite intriguing. Meanwhile, stress-induced denaturing of cellular proteins greatly affects their tertiary structure and critically disrupts their biological functions, occasionally leading to aggregation for the onset of some pathology. Many recent studies have indicated that protein quality control (PQC systems play key roles in counteracting ‘proteo-stress’, which is comprised of several processes, including protein refolding by heat shock proteins (HSPs and degradation of abnormal proteins by the ubiquitin-proteasome system as well as autophagy.Functional Foods in Health and Disease 2013; 3(10:400-415 Page 401 of 415 Objective: Phytochemicals are xenobiotics, thus their biochemical interactions with animal proteins are considered to occur in a non-specific manner, which raises the possibility that some phytochemicals cause proteo-stress for activating PQC systems. Because their status is thought to be a critical determinant of homeostasis, the physiological functions of phytochemicals may be partially mediated through those unique systems. The present study was thus undertaken to address this possibility. Methods and Results: We focused

  3. Design of a Control System for Quality Maintenance on Cutting Edges of Files Production

    Directory of Open Access Journals (Sweden)

    E. Seabra

    2000-01-01

    Full Text Available The file cutting edges are the most important parameter that influence the performance of the filing operation. The practice shows that the most efficient way of generating these cutting edges is by penetration, by blow, of a cutting tool, which creates a plastic deformation on the file body. The penetration depth is probably the most important factor of the final quality of a file. In the existing machines of files manufacturing, this depth is manually adjusted by the operator, using specific mechanism. This means that files are manufactured on an empirical basis, relying on subjective factors, that do not allow to keep constant quality level of the production. In a research work, being developed in the University of Minho, it is intended to eliminate the subjectivity factors by the means of the evolution of the present “all-mechanical” system to a “mechatronic” one. In this paper, which is related with that research work, it presented a study of a round files production machine, regarding the identification, as well as the categorisation, of the operating parameters that affect the cutting edges production. They are, as well, defined and quantified those factors that influence the final quality of a round file.

  4. Comparative analysis of quality assurance systems which effectively control, review and verify the quality of components manufactured for liquid metal cooled fast breeder reactors within the EEC

    International Nuclear Information System (INIS)

    Benn, L.A.

    1985-01-01

    Comparative analyses are made of Quality Assurance Systems, by techniques and the methodology used, for the manufacture of component parts for the Liquid Metal Cooled Fast Breeder Reactor (LMFBR) within the EEC. Two differing alternative systems are presented in the analysis. First, a tabulated analytical treatment which analyses 14 codes and standards relating to Quality Assurance which can be applied to LMFBR's. The comparison equates equivalent clauses between codes and standards followed by an analysis of individual clauses in tabular form, the International Standard ISO 6215. A statistical summary and recommendations conclude this analysis. The second alternative system used in the comparison is a descriptive analytical method applied to 9 selected codes and standards relating to Quality Assurance based on the 13 criteria of the International IAEA Code of Practice no. 50 C.QA entitled ''Quality Assurance for Safety in Nuclear Power Plants''. An investigation is then made of the state of the art on the subject of classification of component parts bearing generally on Quality Assurance. The method of classification is segregated into General, Safety and Inspection categories. A summary of destructive and non destructive controls that may be applied during the manufacture of LMFBR components is given, together with tests that may be applied to selected components, namely Primary Tank, Secondary Sodium Pump and the Primary Cold Trap allocated to Safety Classes, 1, 2 and 3 respectively. The report concludes with a summary of typical records produced at the delivery of a component

  5. An online real time ultrasonic NDT system for the quality control of spot welding in the automotive industry

    International Nuclear Information System (INIS)

    Athi, N; Wylie, S R; Cullen, J D; Al-Jader, M; Al-Shamma'a, A I; Shaw, A

    2009-01-01

    Resistance spot welding is the main joining technique used for the fabrication of body-in-white structures in the automotive industry. The quality of the welds depends on the profile of the spot welding electrode cap. The increased use of zinc coated steel in the industry increases wear rate of the caps, making quality control more difficult. This paper presents a novel online real time ultrasonic NDE system for resistance spot welding which evaluates every weld as it is formed. SEM results are presented to show the alloying of the electrode caps.

  6. An online real time ultrasonic NDT system for the quality control of spot welding in the automotive industry

    Science.gov (United States)

    Athi, N.; Wylie, S. R.; Cullen, J. D.; Al-Jader, M.; Al-Shamma'a, A. I.; Shaw, A.

    2009-07-01

    Resistance spot welding is the main joining technique used for the fabrication of body-in-white structures in the automotive industry. The quality of the welds depends on the profile of the spot welding electrode cap. The increased use of zinc coated steel in the industry increases wear rate of the caps, making quality control more difficult. This paper presents a novel online real time ultrasonic NDE system for resistance spot welding which evaluates every weld as it is formed. SEM results are presented to show the alloying of the electrode caps.

  7. Quality control analysis at the hospital

    International Nuclear Information System (INIS)

    Kristensen, K.

    1979-01-01

    Quality control analysis is an integral part of quality assurance. In a system as with radiopharmaceuticals where part of the finishing of the product takes place at individual hospitals, the need for quality control analysis at the hospital can be discussed. Data are presented that stresses the importance of quality control by the manufacturer as a basis for limitation of such work at hospitals. A simplified programme is proposed

  8. Establishment for quality control of experimental animal

    International Nuclear Information System (INIS)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus

  9. Establishment for quality control of experimental animal

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae Hwan; Kim, Soo Kwan; Kim, Tae Kyoung

    1999-06-01

    Until now, because we have imported experimental animal from foreign experimental animal corporation, we could have saved money by establishing the quality control of animal in barrier system. In order to improve the quality of animal experiment and efficiency of biomedical study, it is indispensable to control many factors that effect in the experiment. Therefore, it is essential to organize the system of laboratory animal care for enhancing reliability and revivability of experimental results. The purpose of the present investigation was to establish the quality control system of experimental animals that we can provide good quality animals according to the experimental condition of each investigator although the exact quality control system to estimate the infection of bacteria and virus easily remains ill-defined yet. Accordingly, we established the useful quality control system for microbiologic monitoring and environmental monitoring to protect experimental animal from harmful bacteria and virus.

  10. Quality control of radiodiagnostics

    International Nuclear Information System (INIS)

    Alonso Diaz, M.; Castaneda Arronte, M.J.; Matorras Galan, P.; Diaz-Caneja Rodriguez, N.; Gutierrez Diaz Velarde, I.

    1993-01-01

    Since May 1990, a program of quality control of diagnostic X-ray equipment is underway in the University Hospital Marques de Valdecilla. This includes the design and application of measuring specifications and procedures corresponding to the different parameters of the equipment. The specified values are presented, as are those obtained for geometric and exposition parameters using the equipment. The specifications for the geometric parameters are fulfilled in an large proportion (between 52 and 86%) of the units, and the rest can easily be adjusted. However, 85% of the units can be made to operate with a field larger than that of the screen of the image monitor and approximately half of them can operate at a shorter focus-to-patient distance than that specified. With respect to the exposition parameters, in general, these units do not fulfill the specifications and their behavior is not uniform. The results obtained indicate that the equipment studied could be made to comply with the proposed specifications if a Maintenance Program were initiated in coordination with that of Quality Control. (Author)

  11. Rotorcraft system identification techniques for handling qualities and stability and control evaluation

    Science.gov (United States)

    Hall, W. E., Jr.; Gupta, N. K.; Hansen, R. S.

    1978-01-01

    An integrated approach to rotorcraft system identification is described. This approach consists of sequential application of (1) data filtering to estimate states of the system and sensor errors, (2) model structure estimation to isolate significant model effects, and (3) parameter identification to quantify the coefficient of the model. An input design algorithm is described which can be used to design control inputs which maximize parameter estimation accuracy. Details of each aspect of the rotorcraft identification approach are given. Examples of both simulated and actual flight data processing are given to illustrate each phase of processing. The procedure is shown to provide means of calibrating sensor errors in flight data, quantifying high order state variable models from the flight data, and consequently computing related stability and control design models.

  12. System management and quality assurance

    International Nuclear Information System (INIS)

    Sastry, A.M.

    1989-01-01

    This paper describes the principles of system management and shows the relationship to quality assurance. It discusses the need for balanced attention to all the project management controls required for project success

  13. Transportable Payload Operations Control Center reusable software: Building blocks for quality ground data systems

    Science.gov (United States)

    Mahmot, Ron; Koslosky, John T.; Beach, Edward; Schwarz, Barbara

    1994-01-01

    The Mission Operations Division (MOD) at Goddard Space Flight Center builds Mission Operations Centers which are used by Flight Operations Teams to monitor and control satellites. Reducing system life cycle costs through software reuse has always been a priority of the MOD. The MOD's Transportable Payload Operations Control Center development team established an extensive library of 14 subsystems with over 100,000 delivered source instructions of reusable, generic software components. Nine TPOCC-based control centers to date support 11 satellites and achieved an average software reuse level of more than 75 percent. This paper shares experiences of how the TPOCC building blocks were developed and how building block developer's, mission development teams, and users are all part of the process.

  14. Quality control measurements of X-ray image-intensifier television chain systems

    International Nuclear Information System (INIS)

    Henshaw, E.T.

    1989-01-01

    The test methods and limiting values for the following basic parameters of an image intensifier TV system are presented in relation to (a) acceptance tests and (b) constancy tests: automatic gain and brightness control, video voltage output, monitor check (grey scale), geometric distortion, noise (low-contrast detectability), overall imaging ability, limiting resolution, uniformity of resolution, conversion factor, contrast ratio and measurement of field size. Several of these tests make use of the Leeds Test Objects. (author)

  15. Towards an agent based traffic regulation and recommendation system for the on-road air quality control.

    Science.gov (United States)

    Sadiq, Abderrahmane; El Fazziki, Abdelaziz; Ouarzazi, Jamal; Sadgal, Mohamed

    2016-01-01

    This paper presents an integrated and adaptive problem-solving approach to control the on-road air quality by modeling the road infrastructure, managing traffic based on pollution level and generating recommendations for road users. The aim is to reduce vehicle emissions in the most polluted road segments and optimizing the pollution levels. For this we propose the use of historical and real time pollution records and contextual data to calculate the air quality index on road networks and generate recommendations for reassigning traffic flow in order to improve the on-road air quality. The resulting air quality indexes are used in the system's traffic network generation, which the cartography is represented by a weighted graph. The weights evolve according to the pollution indexes and path properties and the graph is therefore dynamic. Furthermore, the systems use the available pollution data and meteorological records in order to predict the on-road pollutant levels by using an artificial neural network based prediction model. The proposed approach combines the benefits of multi-agent systems, Big data technology, machine learning tools and the available data sources. For the shortest path searching in the road network, we use the Dijkstra algorithm over Hadoop MapReduce framework. The use Hadoop framework in the data retrieve and analysis process has significantly improved the performance of the proposed system. Also, the agent technology allowed proposing a suitable solution in terms of robustness and agility.

  16. Employee quality, monitoring environment and internal control

    OpenAIRE

    Chunli Liu; Bin Lin; Wei Shu

    2017-01-01

    We investigate the effect of internal control employees (ICEs) on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX), have higher institutional ow...

  17. An alternative method for noise analysis using pixel variance as part of quality control procedures on digital mammography systems

    International Nuclear Information System (INIS)

    Bouwman, R; Broeders, M; Van Engen, R; Young, K; Lazzari, B; Ravaglia, V

    2009-01-01

    According to the European Guidelines for quality assured breast cancer screening and diagnosis, noise analysis is one of the measurements that needs to be performed as part of quality control procedures on digital mammography systems. However, the method recommended in the European Guidelines does not discriminate sufficiently between systems with and without additional noise besides quantum noise. This paper attempts to give an alternative and relatively simple method for noise analysis which can divide noise into electronic noise, structured noise and quantum noise. Quantum noise needs to be the dominant noise source in clinical images for optimal performance of a digital mammography system, and therefore the amount of electronic and structured noise should be minimal. For several digital mammography systems, the noise was separated into components based on the measured pixel value, standard deviation (SD) of the image and the detector entrance dose. The results showed that differences between systems exist. Our findings confirm that the proposed method is able to discriminate systems based on their noise performance and is able to detect possible quality problems. Therefore, we suggest to replace the current method for noise analysis as described in the European Guidelines by the alternative method described in this paper.

  18. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Leme, P.R.

    1983-01-01

    The following topics are discussed: objectives of the quality control in nuclear medicine; the necessity of the quality control in nuclear medicine; guidelines and recommendations. An appendix is given concerning the guidelines for the quality control and instrumentation in nuclear medicine. (M.A.) [pt

  19. Procedure guide for the implementation of quality management program in products and services link with the utilization of tracers technology (TT) and Nucleonic Control System

    International Nuclear Information System (INIS)

    Maggio Noldor, E.; Banados Perez, H.; Longo, G.; Kohnenkamp O, I.; Rodriguez Cardona, R.L.; Sebastian Calvo, C.; Vitart, X.

    1999-01-01

    This Guide was elaborated in the mark of the project RLA/8/024 ARCAL XLII 'Industrial Applications of the Tracer Technology and Nucleonic Control Systems'. Its objective is to establish the approaches for the implementation of quality management system in Tracer Techniques and Nucleonic Control System. The industry application of both techniques are increasing every day in Latin America, so it become in a necessity the implementation of quality control. This paper have 7 chapter. I. Introduction, II. General concepts, III. Proposal of the guide, IV. Verification process about the adhesion all the countries to the quality system; V. Requirement of the system; VI. Term and levels of implementation; VII. Glossary

  20. A review of randomized controlled trials of medical record powered clinical decision support system to improve quality of diabetes care.

    Science.gov (United States)

    Ali, Syed Mustafa; Giordano, Richard; Lakhani, Saima; Walker, Dawn Marie

    2016-03-01

    A gap between current diabetes care practice and recommended diabetes care standards has consistently been reported in the literature. Many IT-based interventions have been developed to improve adherence to the quality of care standards for chronic illness like diabetes. The widespread implementation of electronic medical/health records has catalyzed clinical decision support systems (CDSS) which may improve the quality of diabetes care. Therefore, the objective of the review is to evaluate the effectiveness of CDSS in improving quality of type II diabetes care. Moreover, the review aims to highlight the key indicators of quality improvement to assist policy makers in development of future diabetes care policies through the integration of information technology and system. Setting inclusion criteria, a systematic literature search was conducted using Medline, Web of Science and Science Direct. Critical Appraisal Skills Programme (CASP) tools were used to evaluate the quality of studies. Eight randomized controlled trials (RCTs) were selected for the review. In the selected studies, seventeen clinical markers of diabetes care were discussed. Three quality of care indicators were given more importance in monitoring the progress of diabetes care, which is consistent with National Institute for Health and Care Excellence (NICE) guidelines. The presence of these indicators in the studies helped to determine which studies were selected for review. Clinical- and process-related improvements are compared between intervention group using CDSS and control group with usual care. Glycated hemoglobin (HbA1c), low density lipid cholesterol (LDL-C) and blood pressure (BP) were the quality of care indicators studied at the levels of process of care and clinical outcome. The review has found both inconsistent and variable results for quality of diabetes care measures. A significant improvement has been found in the process of care for all three measures of quality of diabetes care

  1. Efficiency of the functioning of the state control system for the safety and quality of animal products in Ukraine

    Directory of Open Access Journals (Sweden)

    I. Kyryliuk

    2017-12-01

    Full Text Available The study reveals the results of evaluating the effectiveness of the state control system (supervision on the safety and individual indicators of the quality of livestock products in Ukraine. The necessity of application of such components of efficiency as legislation, management and its organizational structure, inspection and laboratory service, information, training and communications is substantiated. It has been determined that during a sufficiently long period of time (until 2015, the system of state control (supervision was archaic and actually focused on the principles of command and administrative economy. The modern tendencies and specifics of the improvement of the Ukrainian control system in the direction of its harmonization with the European one are shown. The emphasis was on significant volumes of work that needed to be done in a very short time, as well as in the absence of adequate funding and appropriate skilled specialists. The emergence of clarity and unambiguousness in determining the responsibility of market operators for violating the legislation requirements in the field of production and circulation of animal origin food products was emphasized. Along with the achievements, there were identified systemic problems related to the technical regulation of safety assurance processes and individual quality indicators in Ukraine. Also it was noted and revealed that legislation in the area of guaranteeing the quality and safety of livestock products in Ukraine remains incomplete and not fully developed. The necessity of development of a number of by-laws and allocation of necessary financing for effective functioning of the state control system over product safety is substantiated. Article specified on the presence of insufficient number of professional inspection and laboratory services is underlined. The mechanisms of avoiding corruption risks and excessive pressure on the subjects of the livestock production market are

  2. Implementation of imaging of the national protocol for quality control in planning systems; Implementacion de pruebas de imagen del protocolo nacional de control de calidad en sistemas de planificacion

    Energy Technology Data Exchange (ETDEWEB)

    Caudepon Moreno, F.; Martin-Viera cueto, J. A.; Bodineau gil, C.; Benitez Villegas, E. M.; Casado Villalon, F. J.; Moreno Sainz, C.

    2011-07-01

    Quality control of the planning system (SP) plays a key role in quality assurance schemes that include all stages of the radiotherapy process.In this work we focus on the evidence detailing the {sup P}rotocol for quality control in therapy planning systems with ionizing radiation of the SEFM in {sup a}natomical data acquisition (DA).

  3. Quality control in urinalysis.

    Science.gov (United States)

    Takubo, T; Tatsumi, N

    1999-01-01

    Quality control (QC) has been introduced in laboratories, and QC surveys in urinalysis have been performed by College of American Pathologist, by Japanese Association of Medical Technologists, by Osaka Medical Association and by manufacturers. QC survey in urinalysis for synthetic urine by the reagent strip and instrument made in same manufacturer, and by an automated urine cell analyser provided satisfactory results among laboratories. QC survey in urinalysis for synthetic urine by the reagent strips and instruments made by various manufacturers indicated differences in the determination values among manufacturers, and between manual and automated methods because the reagent strips and instruments have different characteristics, respectively. QC photo survey in urinalysis on the microscopic photos of urine sediment constituents indicated differences in the identification of cells among laboratories. From the results, it is necessary to standardize a reagent strip method, manual and automated methods, and synthetic urine.

  4. Application of QC_DR software for acceptance testing and routine quality control of direct digital radiography systems: initial experiences using the Italian Association of Physicist in Medicine quality control protocol.

    Science.gov (United States)

    Nitrosi, Andrea; Bertolini, Marco; Borasi, Giovanni; Botti, Andrea; Barani, Adriana; Rivetti, Stefano; Pierotti, Luisa

    2009-12-01

    Ideally, medical x-ray imaging systems should be designed to deliver maximum image quality at an acceptable radiation risk to the patient. Quality assurance procedures are employed to ensure that these standards are maintained. A quality control protocol for direct digital radiography (DDR) systems is described and discussed. Software to automatically process and analyze the required images was developed. In this paper, the initial results obtained on equipment of different DDR manufacturers were reported. The protocol was developed to highlight even small discrepancies in standard operating performance.

  5. Quality control of secondary standards and calibration systems, therapy level, of National Laboratory of Metrology from Ionizing Radiations (LNMRI)

    International Nuclear Information System (INIS)

    Cecatti, E.R.; Freitas, L.C. de

    1992-01-01

    The results of quality control program of secondary standards, therapy level, and the calibration system of clinical dosemeters were analysed from 1984, when a change in the laboratory installation occurred and new standards were obtained. The national and the international intercomparisons were emphasised. The results for graphite wall chambers were compared, observing a maximum variation of about 0,6%. In the case of Delrin (TK01) wall chambers, the maximum variation was 1,7%. The results of post intercomparisons with thermoluminescent dosemeters have presented derivations lesser than 1%, securing the standards consistence at LNMRI with the international metrological system. (C.G.C.)

  6. A quality evaluation of stabilization of rotation frequency of gas-diesel engines when using an adaptive automatic control system

    Science.gov (United States)

    Zhilenkov, A. A.; Efremov, A. A.

    2017-02-01

    A possibility of quality improvement of stabilization of rotation frequency of the gas-diesels used as prime mover of generator set in the multigenerator units working for abruptly variable load of large power is considered. An evaluation is made on the condition of fuzzy controller use developed and described by the authors in a number of articles. An evaluation has shown that theoretically, the revolution range of a gas-diesel engine may be reduced 25-30 times in case of optimal settings of the controller in the whole power range. The results of modelling showing a considerable quality improvement of transient processes in the investigated system during a sharp change of loading are presented in this article.

  7. Detector Construction Management and Quality Control Establishing and Using a CRISTAL System

    CERN Document Server

    Le Goff, J.M.; Bazan, A.; Le Flour, T.; Lieunard, S.; Murray, S.; Vialle, J.P.; Baker, N.; Estrella, F.; Kovacs, Z.; McClatchey, R.; Organtini, G.; Bityukov, S.

    1998-01-01

    The CRISTAL (Cooperating Repositories and an Information System for Tracking Assembly Lifecycles) project is delivering a software system to facilitate the management of the engineering data collected at each stage of production of CMS. CRISTAL captures all the physical characteristics of CMS components as each sub-detector is tested and assembled. These data are retained for later use in areas such as detector slow control, calibration and maintenance. CRISTAL must, therefore, support different views onto its data dependent on the role of the user. These data viewpoints are investigated in this paper. In the recent past two CMS Notes have been written about CRISTAL. The first note, CMS 1996/003, detailed the requirements for CRISTAL, its relationship to other CMS software, its objectives and reviewed the technology on which it would be based. CMS 1997/104 explained some important design concepts on which CRISTAL is and showed how CRISTAL integrated the domains of product data man- agement and workflow manage...

  8. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  9. Many roads may lead to Rome: Selected features of quality control within environmental assessment systems in the US, NL, CA, and UK

    Energy Technology Data Exchange (ETDEWEB)

    Günther, Markus, E-mail: markus.guenther@tu-berlin.de; Geißler, Gesa; Köppel, Johann

    2017-01-15

    As there is no one-and-only concept on how to precisely define and establish quality control (QC) or quality assurance (QA) in the making of environmental assessments (EA), this paper presents selected features of international approaches that address quality in EA systems in the USA, the Netherlands, Canada, and the United Kingdom. Based on explanative case studies, we highlight the embedding of specific quality control features within the EA systems, the objectives and processes, and relevant transparency challenges. Such features of QC/QA approaches can be considered in cases where substantial quality control and assurance efforts are still missing. Yet further research needs to be conducted on the efficacy of these approaches, which remains beyond the scope of this study. - Highlights: • We present four tools for quality control and assurance from different EA systems. • Approaches vary in institutional setting, objectives, procedures, and transparency. • Highlighted features might provide guidance in cases where QC/QA is still lacking.

  10. International systems for harmonization and quality control by in vivo monitoring and quality control by in vivo monitoring of internal contamination

    Energy Technology Data Exchange (ETDEWEB)

    Malatova, I [National Radiation Protection Inst., Prague (Czech Republic)

    1996-12-31

    After the Chernobyl accident, whole body counting for the monitoring of internal contamination of the population was widely used. In many cases, great discrepancy occurred between in vivo measured values and predicted ones from model calculations. This situation was very similar to the situation in environmental monitoring, however, by sample measurement, quality assurance and quality control of the measurement procedure is much easier than by whole body counting. In addition to it, unlike in environmental monitoring, use of semiconductor detectors by whole counting was rather limited in this time so there were few laboratories which were able to distinguish up to 20 radionuclides by which people from the vicinity of Chernobyl were internally contaminated. Therefore, effort was undertaken by many international organization to summarize current status of whole body counting and to estimate uncertainty and sensitivity of different devices. In this paper efforts to harmonize an interpretation of measured results is given. Whole body counting laboratory of the National Radiation Protection Institute (NRPI) in Prague participates in the above mentioned intercomparisons with good results and scientists from NRPI have participated in the preparation of 3 international recommendations concerning measurement of internal contamination (author).

  11. Quality control programme for radiotherapy

    International Nuclear Information System (INIS)

    Campos de Araujo, A.M.; Viegas, C.C.B.; Viamonte, A.M.

    2002-01-01

    A 3 years pilot programme started in January 2000 with 33 philanthropic cancer institutions that provides medical services to 60% of the patients from the national social security system. Brazil has today 161 radiotherapy services (144 operating with megavoltage equipment). These 33 institutions are distributed over 19 Brazilian states. The aim of this programme is: To create conditions to allow the participants to apply the radiotherapy with quality and efficacy; To promote up dating courses for the physicians, physicists and technicians of these 33 Institutions. With the following objectives: To recommend dosimetric and radiological protection procedures in order to guarantee the tumor prescribed dose and safe working conditions; To help in establishing and implementing these procedures. The main activities are: local quality control evaluations, postal TLD audits in reference conditions, postal TLD audits in off axis conditions and training. The local quality control program has already evaluated 22 institutions with 43 machines (25 Co-60 and 18 linear accelerators). In these visits we perform dosimetric, electrical, mechanical and safety tests. As foreseen, we found more problems among the old Co-60 machines i.e., field flatness, size, symmetry and relative output factors; lasers positioning system alignment; optical distance indicator; radiation and light field coincidence; optical and mechanical distance indicators agreement, than among the linear accelerators i.e., field flatness and size; lasers positioning system alignment; tray interlocking and wedge filter factors

  12. Quality control procedures of dental diagnostic radiology systems; Elaboracao de um procedimento para controle de qualidade em sistemas de radiodiagnostico odontologico

    Energy Technology Data Exchange (ETDEWEB)

    Andrade, Paula Serra Sasaki

    2007-07-01

    This work presents quality control reference procedures for dental diagnostic radiology systems, following the recommendations of the Publication 453 of the Brazilian Health Ministry (PF453), to be applied in dental clinics, in order to achieve an improvement in the radiological image qualities and the patient dose reduction. All tests were applied in an intraoral X rays system, following the methodology developed and the requirements of the PF 453. In order to verify the best quality of the image in relation to the smaller exposition time an object test was also developed in this work. The use of this object allowed the reduction of the exposition time of 0.5 seconds, the maximum value of the linear region of the characteristic curve, for 0.2 seconds. The tested X rays system showed a very good agreement with the applied procedures, detaching the reduction of the skin entrance dose using the film-holding devices. However, the size of the field increased and exceeded the maximum value of 6 cm recommended in the standard. The importance of the quality control in dental diagnostic radiology systems is essential due to the constant use of X radiation in dental clinics. The PF453 recommends the frequency of at least two years for the constancy tests. However, it is suggested that the professional, surgeon-dentist, should be responsible for the internal control of the image quality obtained from the X rays device. This can be done through monthly exposures of the object test developed in this work. (author)

  13. A system identification approach for developing model predictive controllers of antibody quality attributes in cell culture processes.

    Science.gov (United States)

    Downey, Brandon; Schmitt, John; Beller, Justin; Russell, Brian; Quach, Anthony; Hermann, Elizabeth; Lyon, David; Breit, Jeffrey

    2017-11-01

    As the biopharmaceutical industry evolves to include more diverse protein formats and processes, more robust control of Critical Quality Attributes (CQAs) is needed to maintain processing flexibility without compromising quality. Active control of CQAs has been demonstrated using model predictive control techniques, which allow development of processes which are robust against disturbances associated with raw material variability and other potentially flexible operating conditions. Wide adoption of model predictive control in biopharmaceutical cell culture processes has been hampered, however, in part due to the large amount of data and expertise required to make a predictive model of controlled CQAs, a requirement for model predictive control. Here we developed a highly automated, perfusion apparatus to systematically and efficiently generate predictive models using application of system identification approaches. We successfully created a predictive model of %galactosylation using data obtained by manipulating galactose concentration in the perfusion apparatus in serialized step change experiments. We then demonstrated the use of the model in a model predictive controller in a simulated control scenario to successfully achieve a %galactosylation set point in a simulated fed-batch culture. The automated model identification approach demonstrated here can potentially be generalized to many CQAs, and could be a more efficient, faster, and highly automated alternative to batch experiments for developing predictive models in cell culture processes, and allow the wider adoption of model predictive control in biopharmaceutical processes. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers Biotechnol. Prog., 33:1647-1661, 2017. © 2017 The Authors Biotechnology Progress published by Wiley Periodicals, Inc. on behalf of American Institute of Chemical Engineers.

  14. Computer controlled quality of analytical measurements

    International Nuclear Information System (INIS)

    Clark, J.P.; Huff, G.A.

    1979-01-01

    A PDP 11/35 computer system is used in evaluating analytical chemistry measurements quality control data at the Barnwell Nuclear Fuel Plant. This computerized measurement quality control system has several features which are not available in manual systems, such as real-time measurement control, computer calculated bias corrections and standard deviation estimates, surveillance applications, evaluaton of measurement system variables, records storage, immediate analyst recertificaton, and the elimination of routine analysis of known bench standards. The effectiveness of the Barnwell computer system has been demonstrated in gathering and assimilating the measurements of over 1100 quality control samples obtained during a recent plant demonstration run. These data were used to determine equaitons for predicting measurement reliability estimates (bias and precision); to evaluate the measurement system; and to provide direction for modification of chemistry methods. The analytical chemistry measurement quality control activities represented 10% of the total analytical chemistry effort

  15. Quality upgrading and cost reducing effects of using an operation control system for performance of maintenance tasks

    International Nuclear Information System (INIS)

    Ramler, K.

    1996-01-01

    According to available results, the use of an operation control system has come up to expections with respect to a quality enhancement of maintenance work. The tasks are performed more safely and there is more insight into the processes. so that, as indirect results, cost savings and rationalisation effects are to be expected. However, the cost savings achieved through the operation control system for maintenance tasks will remain modest. The truly cost-effective optimisation potentials in the maintenance area primarily consist in a reduction of preventive measures to the required scope, i.e reduction of the envisaged quantity of processes for maintenance and recurrent inspection. In order to extend savings to the organisational level, with respect to personnel expenditure, by DP supported maintenance planning, a suitable optimisation of the organisational structure and personnel employment is inevitable, because otherwise the rationalisation potentials will remain utopia. (orig.) [de

  16. Performance evaluation of the QC-6PLUS quality control system in terms of photons and electrons absorbed doses to water

    International Nuclear Information System (INIS)

    Teixeira, Flavia Cristina da Silva

    2004-06-01

    The quality of the treatment in radiotherapy depends on the necessary knowledge of the liberated dose in the tumor and of several other physical parameters and dosimetric that characterize the profile of the radiation field. Worrying about the reliability of some commercial equipment that aim at determining the main parameters of a radiation field in a practical way for daily checks in an institution with radiotherapy service, in this work a study of the performance of the quality assurance system, QC6-Plus manufactured by PTW-Freiburg for daily checks, was developed, in order to assure the use of this equipment with larger reliability level in the routine of quality assurance of the hospitals as well as to make possible its use in the Program of Regulatory Inspections of the Services of Radiotherapy of the Country accomplished by IRD/CNEN. The found results indicate that the system QC6-Plus is perfectly adapted and practical for relative measures of daily and weekly control of the main parameters of clinical beans in agreement with reference values recommended in TECDOC 1151. However for measurements of absolute dose it should not be used because, for beams of electrons the system does not present the necessary characteristics to execute this measure type in agreement with the reference protocol, TRS 398, and for photons of energy 15 MV presented a deviation in relation to the conventional method of absolute dosimetry of 7,7%, that it is a lot above the expected in agreement with TRS 398. (author)

  17. Development of a dosimetric system for dental X-ray equipment quality control

    International Nuclear Information System (INIS)

    Melo, Francisco Almeida de

    2002-08-01

    An electronic instrument with digital readout was designed and constructed to provide fast, simple and non-invasive measurements of X-ray dental equipment parameters. This instrument is capable of evaluating the entrance dose, exposure time, tube voltage (kVp) and beam filtration. It consists of a set of five photodiodes connected each one in the photocurrent mode to the input of a designed integrating electrometer. Three of the detectors are fixed under aluminium filters with different thicknesses, one is fixed under a 0.3 mm copper filter and the other has no filtration. The readings of the three detectors under aluminium filters and of the bare detector permit the determination of the half-value layer, which is used to calculate the beam filtration. The ratio between the readings of the detector below the copper filter and the one without filtration is used to determine the tube voltage. The signal produced by the detector without filter is used to evaluate the patient entrance dose, and to active an electronic timer for measuring the real exposure time. The tests and calibration of the instrument in different voltages in the 59 - 70kVp range, showed that its response is both stable and reproducible to within 1%. The instrument response was compared to the one from a commercial non-invasive X-ray test equipment (Gammex RMI Multifunction kVp meter). The results showed that the response of the developed instrument is in good agreement with the RMI meter which is the standard equipment for such measurements. These results indicate that the dosimetric system is suitable for use in Dental Quality Assurance Programs. (author)

  18. Measurement and Management of the Level of Quality Control Process in SoC (System on Chip Embedded Software Development

    Directory of Open Access Journals (Sweden)

    Ki-Won Song

    2012-04-01

    Full Text Available This paper presents the process of measuring the level of quality control process to ensure the quality of delivered software package during the development cycle. The success of the project requires three pre-requisites and they constrain one another. Quality is the most important factor for successful project completion. In other words, quality should not be sacrificed for the sake of meeting cost budget or delivering within schedule. Also, cost caused by any quality issues such as defect resolution increases exponentially once the product is out of the door. Having said that, we also have to consider the schedule side of constraints for the successful project. In other words, we have no time to do a quality job and we have to compete with other competitors to ship the product to the market earlier than them. So, the quality measurement and management concept is introduced to meet the agile software development environment in conjunction with performance strategies to execute within organization. Obviously, there are many key performance indexes derivable from the actual data associated with quality control activities and it is desirable to create a quality process to integrally represent overall level of quality control activities performed while developing the software deliverables. With the quality process, it is possible to evaluate whether enough quality control activities are performed for the project officially and secure the quality of the software deliverables before it is delivered to the customers.

  19. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS (A Toroidal LHC Apparatus). The ALFA system is composed by four stations installed in the LHC tunnel 240 m away from the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronics for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  20. ALFA Detector Control System

    CERN Document Server

    Oleiro Seabra, Luis Filipe; The ATLAS collaboration

    2015-01-01

    ALFA (Absolute Luminosity For ATLAS) is one of the sub-detectors of ATLAS/LHC. The ALFA system is composed by two stations installed in the LHC tunnel 240 m away from each side of the ATLAS interaction point. Each station has a vacuum and ventilation system, movement control and all the required electronic for signal processing. The Detector Control System (DCS) provides control and monitoring of several components and ensures the safe operation of the detector contributing to good Data Quality. This paper describes the ALFA DCS system including a detector overview, operation aspects and hardware control through a SCADA system, WinCC OA.

  1. Metrology and quality control handbook

    International Nuclear Information System (INIS)

    Hofmann, D.

    1983-01-01

    This book tries to present the fundamentals of metrology and quality control in brief surveys. Compromises had to be made in order to reduce the material available to a sensible volume for the sake of clarity. This becomes evident by the following two restrictions which had to made: First, in dealing with the theoretical principles of metrology and quality control, mere reference had to be made in many cases to the great variety of special literature without discussing it to explain further details. Second, in dealing with the application of metrology and quality control techniques in practice, only the basic qantities of the International System of Units (SI) could be taken into account as a rule. Some readers will note that many special measuring methods and equipment known to them are not included in this book. I do hope, however, that this short-coming will show to have a positive effect, too. This book will show the reader how to find the basic quantities and units from the derived quantities and units, and the steps that are necessary to solve any kind of measuring task. (orig./RW) [de

  2. Employee quality, monitoring environment and internal control

    Directory of Open Access Journals (Sweden)

    Chunli Liu

    2017-03-01

    Full Text Available We investigate the effect of internal control employees (ICEs on internal control quality. Using special survey data from Chinese listed firms, we find that ICE quality has a significant positive influence on internal control quality. We examine the effect of monitoring on this result and find that the effect is more pronounced for firms with strict monitoring environments, especially when the firms implement the Chinese internal control regulation system (CSOX, have higher institutional ownership or attach greater importance to internal control. Our findings suggest that ICEs play an important role in the design and implementation of internal control systems. Our study should be of interest to both top managers who wish to improve corporate internal control quality and regulators who wish to understand the mechanisms of internal control monitoring.

  3. Laser system for remote sensing monitoring of air pollution and quality control of the atmosphere

    Directory of Open Access Journals (Sweden)

    Belić Ilija

    2012-01-01

    Full Text Available Monitoring of the atmosphere and determination of the types and amounts of pollutants is becoming more important issue in complex and global monitoring of the environment. On the geocomponent and geocomplex level problem of monitoring the environment is attracting the attention of the scientific experts of different profiles (chemists, physicists, geographers, biologists, meteorologists, both in the national and international projects. Because of the general characteristics of the Earth's atmosphere (Dynamically Ballanced Instability DBI and the potential contribution to climate change solutions air-pollution monitoring has become particularly important field of environmental research. Control of aerosol distribution over Europe is enabled by EARLINET systems (European Aerosol Lidar NETwork. Serbia’s inclusion into these European courses needs development of the device, the standardization of methods and direct activity in determining the type, quantity and location of aerosol. This paper is analyzing the first step in the study of air-pollution, which is consisted of the realization of a functional model of LIDAR remote sensing devices for the large particle pollutants.

  4. Quality control of the treatment planning systems dose calculations in external radiation therapy using the Penelope Monte Carlo code; Controle qualite des systemes de planification dosimetrique des traitements en radiotherapie externe au moyen du code Monte-Carlo Penelope

    Energy Technology Data Exchange (ETDEWEB)

    Blazy-Aubignac, L

    2007-09-15

    The treatment planning systems (T.P.S.) occupy a key position in the radiotherapy service: they realize the projected calculation of the dose distribution and the treatment duration. Traditionally, the quality control of the calculated distribution doses relies on their comparisons with dose distributions measured under the device of treatment. This thesis proposes to substitute these dosimetry measures to the profile of reference dosimetry calculations got by the Penelope Monte-Carlo code. The Monte-Carlo simulations give a broad choice of test configurations and allow to envisage a quality control of dosimetry aspects of T.P.S. without monopolizing the treatment devices. This quality control, based on the Monte-Carlo simulations has been tested on a clinical T.P.S. and has allowed to simplify the quality procedures of the T.P.S.. This quality control, in depth, more precise and simpler to implement could be generalized to every center of radiotherapy. (N.C.)

  5. Internal quality control: best practice.

    Science.gov (United States)

    Kinns, Helen; Pitkin, Sarah; Housley, David; Freedman, Danielle B

    2013-12-01

    There is a wide variation in laboratory practice with regard to implementation and review of internal quality control (IQC). A poor approach can lead to a spectrum of scenarios from validation of incorrect patient results to over investigation of falsely rejected analytical runs. This article will provide a practical approach for the routine clinical biochemistry laboratory to introduce an efficient quality control system that will optimise error detection and reduce the rate of false rejection. Each stage of the IQC system is considered, from selection of IQC material to selection of IQC rules, and finally the appropriate action to follow when a rejection signal has been obtained. The main objective of IQC is to ensure day-to-day consistency of an analytical process and thus help to determine whether patient results are reliable enough to be released. The required quality and assay performance varies between analytes as does the definition of a clinically significant error. Unfortunately many laboratories currently decide what is clinically significant at the troubleshooting stage. Assay-specific IQC systems will reduce the number of inappropriate sample-run rejections compared with the blanket use of one IQC rule. In practice, only three or four different IQC rules are required for the whole of the routine biochemistry repertoire as assays are assigned into groups based on performance. The tools to categorise performance and assign IQC rules based on that performance are presented. Although significant investment of time and education is required prior to implementation, laboratories have shown that such systems achieve considerable reductions in cost and labour.

  6. Hydrogeological controls of variable microbial water quality in a complex subtropical karst system in Northern Vietnam

    Science.gov (United States)

    Ender, Anna; Goeppert, Nadine; Goldscheider, Nico

    2018-05-01

    Karst aquifers are particularly vulnerable to bacterial contamination. Especially in developing countries, poor microbial water quality poses a threat to human health. In order to develop effective groundwater protection strategies, a profound understanding of the hydrogeological setting is crucial. The goal of this study was to elucidate the relationships between high spatio-temporal variability in microbial contamination and the hydrogeological conditions. Based on extensive field studies, including mapping, tracer tests and hydrochemical analyses, a conceptual hydrogeological model was developed for a remote and geologically complex karst area in Northern Vietnam called Dong Van. Four different physicochemical water types were identified; the most important ones correspond to the karstified Bac Son and the fractured Na Quan aquifer. Alongside comprehensive investigation of the local hydrogeology, water quality was evaluated by analysis for three types of fecal indicator bacteria (FIB): Escherichia coli, enterococci and thermotolerant coliforms. The major findings are: (1) Springs from the Bac Son formation displayed the highest microbial contamination, while (2) springs that are involved in a polje series with connections to sinking streams were distinctly more contaminated than springs with a catchment area characterized by a more diffuse infiltration. (3) FIB concentrations are dependent on the season, with higher values under wet season conditions. Furthermore, (4) the type of spring capture also affects the water quality. Nevertheless, all studied springs were faecally impacted, along with several shallow wells within the confined karst aquifer. Based on these findings, effective protection strategies can be developed to improve groundwater quality.

  7. CNEA's quality system documentation

    International Nuclear Information System (INIS)

    Mazzini, M.M.; Garonis, O.H.

    1998-01-01

    Full text: To obtain an effective and coherent documentation system suitable for CNEA's Quality Management Program, we decided to organize the CNEA's quality documentation with : a- Level 1. Quality manual. b- Level 2. Procedures. c-Level 3. Qualities plans. d- Level 4: Instructions. e- Level 5. Records and other documents. The objective of this work is to present a standardization of the documentation of the CNEA's quality system of facilities, laboratories, services, and R and D activities. Considering the diversity of criteria and formats for elaboration the documentation by different departments, and since ultimately each of them generally includes the same quality management policy, we proposed the elaboration of a system in order to improve the documentation, avoiding unnecessary time wasting and costs. This will aloud each sector to focus on their specific documentation. The quality manuals of the atomic centers fulfill the rule 3.6.1 of the Nuclear Regulatory Authority, and the Safety Series 50-C/SG-Q of the International Atomic Energy Agency. They are designed by groups of competent and highly trained people of different departments. The normative procedures are elaborated with the same methodology as the quality manuals. The quality plans which describe the organizational structure of working group and the appropriate documentation, will asses the quality manuals of facilities, laboratories, services, and research and development activities of atomic centers. The responsibilities for approval of the normative documentation are assigned to the management in charge of the administration of economic and human resources in order to fulfill the institutional objectives. Another improvement aimed to eliminate unnecessary invaluable processes is the inclusion of all quality system's normative documentation in the CNEA intranet. (author) [es

  8. Air Quality System (AQS)

    Science.gov (United States)

    The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements include both criteria air pollutants and hazardous air pollutants.

  9. Air Quality System (AQS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — The Air Quality System (AQS) database contains measurements of air pollutant concentrations from throughout the United States and its territories. The measurements...

  10. Development of a software for the control of the quality management system of the TRIGA-Mark III reactor

    International Nuclear Information System (INIS)

    Herrera A, E.; Hernandez, L.V.; Hernandez, J.A.

    2006-01-01

    The quality has not only become one of the essential requirements of the product but rather at the present time it is a strategic factor key of which depends the bigger part of the organizations, not only to maintain their position in the market but also to assure their survival. The good organizations will have processes, procedures and standards to confront these challenges. The big organizations require of the certification of their administration systems, and once the organization has obtained this certification the following step it is to maintain it. The implementation and certification of an administration system requires of an appropriate operative organization that achieves continuous improvements in their operation. This is the case of the TRIGA Mark III reactor, which contains a computer program that upgrades, it controls and it programs activities to develop in the Installation, allowing one operative organization to the whole personnel of the same one. With the purpose of avoiding activities untimely. (Author)

  11. Core Community Specifications for Electron Microprobe Operating Systems: Software, Quality Control, and Data Management Issues

    Science.gov (United States)

    Fournelle, John; Carpenter, Paul

    2006-01-01

    Modem electron microprobe systems have become increasingly sophisticated. These systems utilize either UNIX or PC computer systems for measurement, automation, and data reduction. These systems have undergone major improvements in processing, storage, display, and communications, due to increased capabilities of hardware and software. Instrument specifications are typically utilized at the time of purchase and concentrate on hardware performance. The microanalysis community includes analysts, researchers, software developers, and manufacturers, who could benefit from exchange of ideas and the ultimate development of core community specifications (CCS) for hardware and software components of microprobe instrumentation and operating systems.

  12. Water quality control in Third River Reservoir (Argentina using geographical information systems and linear regression models

    Directory of Open Access Journals (Sweden)

    Claudia Ledesma

    2013-08-01

    Full Text Available Water quality is traditionally monitored and evaluated based upon field data collected at limited locations. The storage capacity of reservoirs is reduced by deposits of suspended matter. The major factors affecting surface water quality are suspended sediments, chlorophyll and nutrients. Modeling and monitoring the biogeochemical status of reservoirs can be done through data from remote sensors. Since the improvement of sensors’ spatial and spectral resolutions, satellites have been used to monitor the interior areas of bodies of water. Water quality parameters, such as chlorophyll-a concentration and secchi disk depth, were found to have a high correlation with transformed spectral variables derived from bands 1, 2, 3 and 4 of LANDSAT 5TM satellite. We created models of estimated responses in regard to values of chlorophyll-a. To do so, we used population models of single and multiple linear regression, whose parameters are associated with the reflectance data of bands 2 and 4 of the sub-image of the satellite, as well as the data of chlorophyll-a obtained in 25 selected stations. According to the physico-chemical analyzes performed, the characteristics of the water in the reservoir of Rio Tercero, correspond to somewhat hard freshwater with calcium bicarbonate. The water was classified as usable as a source of plant treatment, excellent for irrigation because of its low salinity and low residual sodium carbonate content, but unsuitable for animal consumption because of its low salt content.

  13. Quality control of brachytherapy system module Oncentra MasterPlan V3.3 planning; Control de calidad del modulo de braquiterapia del sistema de planificacion Oncentra MasterPlan V3.3

    Energy Technology Data Exchange (ETDEWEB)

    Monja Ray, P. de la; Torres Pozas, S.; Sanchez Carrascal, M.; Macias Verde, D.; Martin Oliva, R.

    2011-07-01

    We present the results of quality control carried out the planning system (SP) MasterPlan Oncentra Brachy, version 3.3 (Nucletron), on the occasion of its launch, following the recommendations proposed in the Protocol for quality control in planning systems therapy with ionizing radiation [SEFM, published by the Spanish Society of Medical Physics (SEFM) in 2005].

  14. A novel approach for quality control system using sensor fusion of infrared and visual image processing for laser sealing of food containers

    Science.gov (United States)

    Al-Habaibeh, A.; Shi, F.; Brown, N.; Kerr, D.; Jackson, M.; Parkin, R. M.

    2004-10-01

    This paper presents a new mechatronic approach of using infrared thermography combined with image processing for the quality control of a laser sealing process for food containers. The suggested approach uses an online infrared system to assess the heat distribution within the container seal in order to guarantee the integrity of the process. Visual image processing is then used for quality assurance to guarantee optimum sealing. The results described in this paper show examples of the capability of the condition monitoring system to detect faults in the sealing process. The results found indicate that the suggested approach could form an effective quality control and assurance system.

  15. Assessing software quality at each step of its life-cycle to enhance reliability of control systems

    International Nuclear Information System (INIS)

    Hardion, V.; Buteau, A.; Leclercq, N.; Abeille, G.; Pierre-Joseph, Z.; Le, S.

    2012-01-01

    A distributed software control system aims to enhance the upgrade ability and reliability by sharing responsibility between several components. The disadvantage is that it makes it harder to detect problems on a significant number of modules. With Kaizen in mind we have chosen to continuously invest in automation to obtain a complete overview of software quality despite the growth of legacy code. The development process has already been mastered by staging each life-cycle step thanks to a continuous integration server based on JENKINS and MAVEN. We enhanced this process, focusing on 3 objectives: Automatic Test, Static Code Analysis and Post-Mortem Supervision. Now, the build process automatically includes a test section to detect regressions, incorrect behaviour and integration incompatibility. The in-house TANGOUNIT project satisfies the difficulties of testing distributed components such as Tango Devices. In the next step, the programming code has to pass a complete code quality check-up. The SONAR quality server has been integrated in the process, to collect each static code analysis and display the hot topics on summary web pages. Finally, the integration of Google BREAKPAD in every TANGO Devices gives us essential statistics from crash reports and enables us to replay the crash scenarios at any time. We have already gained greater visibility on current developments. Some concrete results will be presented including reliability enhancement, better management of subcontracted software development, quicker adoption of coding standards by new developers and understanding of impacts when moving to a new technology. (authors)

  16. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2004-01-01

    This volume treats the four main categories of Statistical Quality Control: General SQC Methodology, On-line Control including Sampling Inspection and Statistical Process Control, Off-line Control with Data Analysis and Experimental Design, and, fields related to Reliability. Experts with international reputation present their newest contributions.

  17. Metallographic quality control of welding and brazing

    International Nuclear Information System (INIS)

    Slaughter, G.M.

    1979-01-01

    The value of metallography in assuring integrity in the fabrication of metal and components in energy systems is summarized. Metallography also plays an integral role in quality control of welded and brazed joints

  18. Quality education as quality system support

    International Nuclear Information System (INIS)

    Crnoshia, L.; Gavriloska, M.; Denkovska, J.; Dimitrovski, A.

    1999-01-01

    Within the last ten years we are witnesses of the political and economical system transformation, that imposed the need for changing the way of thinking and work planning. The quality has become the imperative of working and a precondition for survival in the market. Solving the quality problems seeks planned and systematic approach that supposed appropriate personnel with adequate knowledge in the field of quality management and implementation of the quality system. Having in mind the need for documented quality system and quality management OKTA, has already started with personnel educational process for quality as a precondition for successful establishment of quality system. In this paper we present quality education approach and manner of its realization in OKTA Crude Oil Refinery - Skopje, Macedonia. (Original)

  19. The Quality System

    DEFF Research Database (Denmark)

    Brogaard Buus, Daniel; Eland, Morten Vestergaard; Lystlund, Rasmus

    2015-01-01

    In this article, we present our efforts to try to increase cohesiveness and connectivity between quests generated by a recreation of an existing procedural quest generation system, with an addition of a progressive tier system called Quality System. A study gave strong indications that the Qualit...... System successfully produced a positive effect on the feeling of cohesiveness and connectivity between the generated quests amongst Role-playing- and Massively Multiplayer Online games players....

  20. Quality control of CT systems by automated monitoring of key performance indicators: a two-year study.

    Science.gov (United States)

    Nowik, Patrik; Bujila, Robert; Poludniowski, Gavin; Fransson, Annette

    2015-07-08

    The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two-year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service.

  1. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  2. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  3. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  4. Dosimetric study for characterization of a postal system of quality control in brachytherapy

    International Nuclear Information System (INIS)

    Alves, Victor Gabriel Leandro; Queiroz Filho, Pedro Pacheco de; Santos, Denison de Souza; Begalli, Marcia

    2009-01-01

    This work presents a dosimetric study of a postal system, to be developed for measurements of brachytherapy. It was projected a PMMA phantom with orifices for insertion of the high dose 192 Ir source and the T L dosemeters. The system was characterized with using of Monte Carlo simulations, using the dosimetric magnitudes defined at the T G-43 of AAPM, as function of radial dose g(f)

  5. Developing a Continuous Quality Improvement Assessment Using a Patient-Centered Approach in Optimizing Systemic Lupus Erythematosus Disease Control.

    Science.gov (United States)

    Updyke, Katelyn Mariko; Urso, Brittany; Beg, Shazia; Solomon, James

    2017-10-09

    Systemic lupus erythematosus (SLE) is a multi-organ, autoimmune disease in which patients lose self-tolerance and develop immune complexes which deposit systemically causing multi-organ damage and inflammation. Patients often experience unpredictable flares of symptoms with poorly identified triggers. Literature suggests exogenous exposures may contribute to flares in symptoms. An online pilot survey was marketed globally through social media to self-reported SLE patients with the goal to identify specific subpopulations who are susceptible to disease state changes based on analyzed exogenous factors. The pilot survey was promoted for two weeks, 80 respondents fully completed the survey and were included in statistical analysis. Descriptive statistical analysis was performed on de-identified patient surveys and compared to previous literature studies reporting known or theorized triggers in the SLE disease state. The pilot survey identified similar exogenous triggers compared to previous literature, including antibiotics, increasing beef intake, and metal implants. The goal of the pilot survey is to utilize similar questions to develop a detailed internet-based patient interactive form that can be edited and time stamped as a method to promote continuous quality improvement assessments. The ultimate objective of the platform is to interact with SLE patients from across the globe longitudinally to optimize disease control and improve quality of care by allowing them to avoid harmful triggers.

  6. Higher energy efficiency and better water quality by using model predictive flow control at water supply systems

    NARCIS (Netherlands)

    Bakker, M.; Verberk, J.Q.J.C.; Palmen, L.J.; Sperber, V.; Bakker, G.

    2011-01-01

    Half of all water supply systems in the Netherlands are controlled by model predictive flow control; the other half are controlled by conventional level based control. The differences between conventional level based control and model predictive control were investigated in experiments at five full

  7. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  8. New Quality Control Algorithm Based on GNSS Sensing Data for a Bridge Health Monitoring System

    Directory of Open Access Journals (Sweden)

    Jae Kang Lee

    2016-05-01

    Full Text Available This research introduces an improvement plan for the reliability of Global Navigation Satellite System (GNSS positioning solutions. It should be considered the most suitable methodology in terms of the adjustment and positioning of GNSS in order to maximize the utilization of GNSS applications. Though various studies have been conducted with regards to Bridge Health Monitoring System (BHMS based on GNSS, the outliers which depend on the signal reception environment could not be considered until now. Since these outliers may be connected to GNSS data collected from major bridge members, which can reduce the reliability of a whole monitoring system through the delivery of false information, they should be detected and eliminated in the previous adjustment stage. In this investigation, the Detection, Identification, Adaptation (DIA technique was applied and implemented through an algorithm. Moreover, it can be directly applied to GNSS data collected from long span cable stayed bridges and most of outliers were efficiently detected and eliminated simultaneously. By these effects, the reliability of GNSS should be enormously improved. Improvement on GNSS positioning accuracy is directly linked to the safety of bridges itself, and at the same time, the reliability of monitoring systems in terms of the system operation can also be increased.

  9. The quality control and management of the updating of the process measurement and protection system of HFETR

    International Nuclear Information System (INIS)

    Cao Junru; Duan Tianyuan; Zhao Zengqiao; Xing Rujun; Xia Guanghua; Jiang Yiqun

    2001-01-01

    The author emphasizes the presentation of the quality control and management of implement process. Owing to the strict and scientific organizing, the field implement was completed only in 4 months, and comprehensive operation test of reactor was successful at one go. The management target that is safety, high efficiency and high quality, success at one go, was hit

  10. Implementation of a quality control protocol in a radiotherapy planning system

    International Nuclear Information System (INIS)

    Condori, P.; Paucar, R.

    2004-01-01

    Due to the impossibility of each particular case analysis and taking as example the spanish protocol (Under revision), necessary tests have been performed for the verification of the calculations for the Multidata planning system, including: calculation algorithms, reconstruction of the rectangular beams, light modulators, irregular fields, fields summation, weights, normalization, prescription and calculation of UM, for the teletherapy planning

  11. Checks for quality control of wedge dynamics in treatment units and the planning system

    International Nuclear Information System (INIS)

    Mateos Salvador, P.; Rodriguez Lopez, B.; Font Gelabert, J.; Hernandez Rodriguez, J.; Arino Gil, A.

    2013-01-01

    The objective of this study is to verify the implementation of enhanced dynamic wedge (EDW) vary in the Eclipse planning system and the experimental determination of the parameters that define the dosimetry characteristics of enhanced dynamic wedge of our treatment units. (Author)

  12. A Single-Phase Voltage-Controlled Grid-Connected Photovoltaic System With Power Quality Conditioner Functionality

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Liserre, Marco; Mastromauro, R. A.

    2009-01-01

    Future ancillary services provided by photovoltaic (PV) systems could facilitate their penetration in power systems. Also low power PV systems can be designed to improve the power quality. This paper presents a single-phase photovoltaic system that provides grid voltage support and compensation o...

  13. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  14. An anti-Compton suppression Ge-telescope detection system for quality control of nuclear waste packages

    International Nuclear Information System (INIS)

    Agosteo, S.; Para, A. Foglio; Chabalier, B.; Huot, N.; Graf, U.; Ravazzani, A.; Schillebeeckx, P.; Kekki, T.; Tanner, V.; Tiitta, A.

    2001-01-01

    An anti-Compton suppression system is studied for the quality control of radioactive waste packages by nondestructive assay. The main objective is the reduction of the detection limit of actinides in the packages. The optimization of a final device is based on Monte Carlo simulations (MCNP and FLUKA) validated by experiments using a prototype consisting of a Ge-telescope detector surrounded by a NaI detector. The validation reveals that most of the discrepancies between experimental and simulated data are due to an incomplete description of the experimental conditions. After fine-tuning of the input file the uncertainties on the simulated full-energy peak efficiency are reduced to less than 5%. Also the total detector response for mono-energetic photons and real waste, including the photon interactions within the drum, can be simulated satisfactorily

  15. Quality control of the NPL-CRC secondary standard system used for activimeters calibration at IPEN, Sao Paulo, Brazil

    International Nuclear Information System (INIS)

    Martins, Elaine W.; Potiens, Maria da P.A.

    2009-01-01

    The objective of this study was to establish a quality control program to be applied at the NPL-CRC activimeter secondary standard system, used as reference to comparison in tests made with the work tertiary standard activimeter, Capintec basic CRC R -15BT, both belonging to the Calibration Laboratory of IPEN. The repeatability, reproducibility and the precision tests were performed using a sealed check source of 133 Ba, from Amersham. It was made 70 series of 10 measurements to each activimeter, totaling 1400 measurements. Considering the variation limit of 5% to precision and reproducibility tests in the nuclear medicine services, recommended by the Brazilian standard CNEN-NN-3.05, the results observed in the behavior of the IPEN activimeter were satisfactory. (author)

  16. Multiple category-lot quality assurance sampling: a new classification system with application to schistosomiasis control.

    Science.gov (United States)

    Olives, Casey; Valadez, Joseph J; Brooker, Simon J; Pagano, Marcello

    2012-01-01

    Originally a binary classifier, Lot Quality Assurance Sampling (LQAS) has proven to be a useful tool for classification of the prevalence of Schistosoma mansoni into multiple categories (≤10%, >10 and LQAS (MC-LQAS) have not received full treatment. We explore the analytical properties of MC-LQAS, and validate its use for the classification of S. mansoni prevalence in multiple settings in East Africa. We outline MC-LQAS design principles and formulae for operating characteristic curves. In addition, we derive the average sample number for MC-LQAS when utilizing semi-curtailed sampling and introduce curtailed sampling in this setting. We also assess the performance of MC-LQAS designs with maximum sample sizes of n=15 and n=25 via a weighted kappa-statistic using S. mansoni data collected in 388 schools from four studies in East Africa. Overall performance of MC-LQAS classification was high (kappa-statistic of 0.87). In three of the studies, the kappa-statistic for a design with n=15 was greater than 0.75. In the fourth study, where these designs performed poorly (kappa-statistic less than 0.50), the majority of observations fell in regions where potential error is known to be high. Employment of semi-curtailed and curtailed sampling further reduced the sample size by as many as 0.5 and 3.5 observations per school, respectively, without increasing classification error. This work provides the needed analytics to understand the properties of MC-LQAS for assessing the prevalance of S. mansoni and shows that in most settings a sample size of 15 children provides a reliable classification of schools.

  17. Multiple category-lot quality assurance sampling: a new classification system with application to schistosomiasis control.

    Directory of Open Access Journals (Sweden)

    Casey Olives

    Full Text Available Originally a binary classifier, Lot Quality Assurance Sampling (LQAS has proven to be a useful tool for classification of the prevalence of Schistosoma mansoni into multiple categories (≤10%, >10 and <50%, ≥50%, and semi-curtailed sampling has been shown to effectively reduce the number of observations needed to reach a decision. To date the statistical underpinnings for Multiple Category-LQAS (MC-LQAS have not received full treatment. We explore the analytical properties of MC-LQAS, and validate its use for the classification of S. mansoni prevalence in multiple settings in East Africa.We outline MC-LQAS design principles and formulae for operating characteristic curves. In addition, we derive the average sample number for MC-LQAS when utilizing semi-curtailed sampling and introduce curtailed sampling in this setting. We also assess the performance of MC-LQAS designs with maximum sample sizes of n=15 and n=25 via a weighted kappa-statistic using S. mansoni data collected in 388 schools from four studies in East Africa.Overall performance of MC-LQAS classification was high (kappa-statistic of 0.87. In three of the studies, the kappa-statistic for a design with n=15 was greater than 0.75. In the fourth study, where these designs performed poorly (kappa-statistic less than 0.50, the majority of observations fell in regions where potential error is known to be high. Employment of semi-curtailed and curtailed sampling further reduced the sample size by as many as 0.5 and 3.5 observations per school, respectively, without increasing classification error.This work provides the needed analytics to understand the properties of MC-LQAS for assessing the prevalance of S. mansoni and shows that in most settings a sample size of 15 children provides a reliable classification of schools.

  18. Effect of a web-based chronic disease management system on asthma control and health-related quality of life: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Ahmed, Sara; Bartlett, Susan J; Ernst, Pierre; Paré, Guy; Kanter, Maria; Perreault, Robert; Grad, Roland; Taylor, Laurel; Tamblyn, Robyn

    2011-12-14

    Asthma is a prevalent and costly disease resulting in reduced quality of life for a large proportion of individuals. Effective patient self-management is critical for improving health outcomes. However, key aspects of self-management such as self-monitoring of behaviours and symptoms, coupled with regular feedback from the health care team, are rarely addressed or integrated into ongoing care. Health information technology (HIT) provides unique opportunities to facilitate this by providing a means for two way communication and exchange of information between the patient and care team, and access to their health information, presented in personalized ways that can alert them when there is a need for action. The objective of this study is to evaluate the acceptability and efficacy of using a web-based self-management system, My Asthma Portal (MAP), linked to a case-management system on asthma control, and asthma health-related quality of life. The trial is a parallel multi-centered 2-arm pilot randomized controlled trial. Participants are randomly assigned to one of two conditions: a) MAP and usual care; or b) usual care alone. Individuals will be included if they are between 18 and 70, have a confirmed asthma diagnosis, and their asthma is classified as not well controlled by their physician. Asthma control will be evaluated by calculating the amount of fast acting beta agonists recorded as dispensed in the provincial drug database, and asthma quality of life using the Mini Asthma Related Quality of Life Questionnaire. Power calculations indicated a needed total sample size of 80 subjects. Data are collected at baseline, 3, 6, and 9 months post randomization. Recruitment started in March 2010 and the inclusion of patients in the trial in June 2010. Self-management support from the care team is critical for improving chronic disease outcomes. Given the high volume of patients and time constraints during clinical visits, primary care physicians have limited time to

  19. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  20. PACS quality control and automatic problem notifier

    Science.gov (United States)

    Honeyman-Buck, Janice C.; Jones, Douglas; Frost, Meryll M.; Staab, Edward V.

    1997-05-01

    One side effect of installing a clinical PACS Is that users become dependent upon the technology and in some cases it can be very difficult to revert back to a film based system if components fail. The nature of system failures range from slow deterioration of function as seen in the loss of monitor luminance through sudden catastrophic loss of the entire PACS networks. This paper describes the quality control procedures in place at the University of Florida and the automatic notification system that alerts PACS personnel when a failure has happened or is anticipated. The goal is to recover from a failure with a minimum of downtime and no data loss. Routine quality control is practiced on all aspects of PACS, from acquisition, through network routing, through display, and including archiving. Whenever possible, the system components perform self and between platform checks for active processes, file system status, errors in log files, and system uptime. When an error is detected or a exception occurs, an automatic page is sent to a pager with a diagnostic code. Documentation on each code, trouble shooting procedures, and repairs are kept on an intranet server accessible only to people involved in maintaining the PACS. In addition to the automatic paging system for error conditions, acquisition is assured by an automatic fax report sent on a daily basis to all technologists acquiring PACS images to be used as a cross check that all studies are archived prior to being removed from the acquisition systems. Daily quality control is preformed to assure that studies can be moved from each acquisition and contrast adjustment. The results of selected quality control reports will be presented. The intranet documentation server will be described with the automatic pager system. Monitor quality control reports will be described and the cost of quality control will be quantified. As PACS is accepted as a clinical tool, the same standards of quality control must be established

  1. Quality control of JEOL JBX-9500FSZ e-beam lithography system in a multi-user laboratory

    DEFF Research Database (Denmark)

    Greibe, Tine; Anhøj, Thomas Aarøe; Johansen, Leif

    2016-01-01

    designed quality control procedure characterized using a scanning electron microscope. We inspect position accuracy, dynamic focus, and dynamic astigmatism, as well as single and multi-pixel lines in thin resist. Beam shape quality is inspected in the corners of the writing field at 6 different beam...... currents between 2 and 60 nA. We use positive-tone resist AR-P6200 (CSAR 62) from All Resist. With our quality control procedure, we routinely write 11 nm lines on a 40 nm pitch, and obtain a field stitching accuracy better than 3 nm and overlay accuracy less than 7 nm....

  2. Quality control of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Wallen, O.; Komarov, E.

    1973-01-01

    The International Pharmacopoeia published by WHO constitutes a collection of recommended specifications for pharmaceutical preparations which are not intended to have legal status in any country, but serve as references so that national specifications can be established on a similar basis in any country. Like any pharmacopoeia, it contains monographs for the quality con trol of drugs by means of chemical, physical and simple biological methods, as well as appendices describing general methods. The work on the International Pharmacopoeia is carried out by WHO with the aid of the Expert Advisory Panel on the International Pharmacopoeia and Pharmaceutical Preparations and other specialists from various countries and the Expert Committee on Specifications for Pharmaceutical Preparations. (author)

  3. Constructed Rain Garden Systems for Stormwater Quality Control under Tropical Climates

    Science.gov (United States)

    Mohd Sidek, Lariyah; Elyza Muha, Norshafa; Noor, Nur Asmaliza Md; Basri, Hidayah

    2013-06-01

    Malaysia has taken an integrated approach to manage storm water that is increasingly becoming a problem in big cities. Rain gardens are recommended as green technology for a new storm water management in Malaysia. The approach is applied in urban planning and design that integrates the total water cycle management into the development process areas. Rain gardens have been effective in reducing peak discharge and consistently reduce the number of storm water pollutants. This paper will examine some of guidelines, laboratory studies and field monitoring that shows great potential and benefit of rain garden. The preliminary results for rain garden performance were reported in this paper. The findings from this research will open avenues for researchers to advance the knowledge in rain garden systems to achieve the sustainable development in Malaysia.

  4. Constructed Rain Garden Systems for Stormwater Quality Control under Tropical Climates

    International Nuclear Information System (INIS)

    Sidek, Lariyah Mohd; Noor, Nur Asmaliza Md; Basri, Hidayah; Muha, Norshafa Elyza

    2013-01-01

    Malaysia has taken an integrated approach to manage storm water that is increasingly becoming a problem in big cities. Rain gardens are recommended as green technology for a new storm water management in Malaysia. The approach is applied in urban planning and design that integrates the total water cycle management into the development process areas. Rain gardens have been effective in reducing peak discharge and consistently reduce the number of storm water pollutants. This paper will examine some of guidelines, laboratory studies and field monitoring that shows great potential and benefit of rain garden. The preliminary results for rain garden performance were reported in this paper. The findings from this research will open avenues for researchers to advance the knowledge in rain garden systems to achieve the sustainable development in Malaysia.

  5. Control by quality: proposition of a typology.

    Science.gov (United States)

    Pujo, P; Pillet, M

    The application of Quality tools and methods in industrial management has always had a fundamental impact on the control of production. It influences the behavior of the actors concerned, while introducing the necessary notions and formalizations, especially for production systems with little or no automation, which constitute a large part of the industrial activity. Several quality approaches are applied in the workshop and are implemented at the level of the control. In this paper, the authors present a typology of the various approaches that have successively influenced control, such as statistical process control, quality assurance, and continuous improvement. First the authors present a parallel between production control and quality organizational structure. They note the duality between control, which is aimed at increasing productivity, and quality, which aims to satisfy the needs of the customer. They also note the hierarchical organizational structure of these two systems of management with, at each level, the notion of a feedback loop. This notion is fundamental to any kind of decision making. The paper is organized around the operational, tactical, and strategic levels, by describing for each level the main methods and tools for control by quality. The overview of these tools and methods starts at the operational level, with the Statistical Process Control, the Taguchi technique, and the "six sigma" approach. On the tactical level, we find a quality system approach, with a documented description of the procedures introduced in the firm. The management system can refer here to Quality Assurance, Total Productive Maintenance, or Management by Total Quality. The formalization through procedures of the rules of decision governing the process control enhances the validity of these rules. This leads to the enhancement of their reliability and to their consolidation. All this counterbalances the human, intrinsically fluctuating, behavior of the control

  6. Quality control of labelled compounds

    International Nuclear Information System (INIS)

    Matucha, M.

    1979-01-01

    Some advantages and disadvantages of methods used for quality control of organic labelled compounds (1 31 I, 14 C) are shortly discussed. The methods used are electrophoresis, ultraviolet and infrared spectrometry, radiogas and thin-layer chromatography. (author)

  7. Quality Control for Ordnance

    Science.gov (United States)

    1957-01-01

    R. H. Morgan, "Screen Intensification Systems and Their Lirnita- tions," Amtvican J w n u l of Roenlgenology and Radizcm Therapy , Vol. LXII, No...443. (1 10) Kurt Matthaes, " Magneto -Inductive Testing of Stcel," Zeitschrgt filr Melnll- kunde, Vol. 39, September, 1948, p]). 257- 272. (1 11

  8. CONCRETE STRUCTURES' QUALITY CONTROL IN PRACTICE

    OpenAIRE

    Dolaček-Alduk, Zlata; Blanda, Miroslav

    2011-01-01

    The Croatian civil engineering is characterized by a lack of systematic approach to planning, control and quality assurance in all phases of project realization. The results obtained in establishing the quality management system in some segments of civil engineering production represent initial trends in solving this problem. Benefits are of two types: the achievement of quality for the contractor and obtaining that quaity is being achieved for clients. Execution of concrete structures is a c...

  9. KWARTA (Quality Assurance in the Radiotherapy centres of the Antwerp province): Quality control of the contract therapy machine and treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    De Ost, B; Schaeken, B; Vanregemorter, J [Algemeen Ziekenhuis Middelheim, Antwerp (Belgium); Bellekens, L [Sint-Vincentius Ziekenhuis, Antwerp (Belgium); Cardoen, R; Pieters, D [Medisch Instituut Sint Augustinus, Wilrijk (Belgium); Goossens, H [Sint-Elisabeth Ziekenhuis, Turnhout (Belgium); Haest, K; Mertens, N [Sint Norbertus Ziekenhuis, Duffel (Belgium)

    1995-12-01

    During the first year of the provincial QA project, joint procedures were set up for the routine quality control of linear accelerators, Cobalt treatment machines and simulators. A set of standard forms was produced for use in all centres, respecting the differences in each individual machine. Since forms are now in use in all centres, the second year of the project mainly focused on the QA/QC of the contract therapy machine and treatment planning system. QC measurements for the contract therapy machines were performed in air or in a phantom. Since the output was checked with the same ionisation chamber (0.33 cc flat chamber calibrated for 50 kV) and the same type of electrometer in all centres, the results could be compared mutually and with the reference values. The major parameter groups, tested for the treatment planning system were: isodose distribution (visual control of all square fields in the database of the system), PDD data (analysing of 10 x 10 cm{sup 2}, 20 x 20 cm{sup 2}, 30 x 30 cm{sup 2} and 40 x 40 cm{sup 2} open or wedged fields), output factors, wedge and tray factors, inverse square law, geometrical testing of the digitizer - screen - printer and geometrical and densitometrical testing of the CT images - screen - printer. Between 496 and 1243 parameters were investigated in the different centres (depending on the presence of the electron data). Irregularities (0 % to 4 % of the total investigated parameters) were reported to the respective physicist.

  10. Establishment of a quality control system of coals; Establecimiento de una Metodologia de Aseguramiento de Calidad en el Analisis de Carbones

    Energy Technology Data Exchange (ETDEWEB)

    1999-09-01

    The pain propose of this project is the establishment of a quality control system in order to assure the feasibility of analytic data used in commercial valorization coals. The programme of quality assurement takes into account the following concepts: - Normalization of analytic methods. - Maintenance and measurements of analysis equipment - Standardization of analysis process. - Quality control inside of laboratory - Standardization of measurement systems between laboratories - External audits of quality process. - Accreditation of alternative systems. - Personnel education necessities. In order to be an useful tool, the programme has been consider under this three aspects: reliableness, rapidness, and simpleness. The process is based in: validation of method, validation of origin, and validation by coherence. All that is integrated in an informatic system. (Author)

  11. Procedure guide for the implementation of quality management program in products and services link with the utilization of tracers technology (TT) and Nucleonic Control System

    International Nuclear Information System (INIS)

    Resnizky, S.; Banados Perez, H.; Longo, G.; Rodriguez Cardona, R.L.; Sebastian Calvo, C.; Kohnenkamp O, I.; Duran P, O.

    2000-01-01

    This Manual was elaborated in the mark of the project RLA/8/024 ARCAL XLII 'Industrial Applications of the Tracer Technology and Nucleonic Control Systems'. The objective of the present Quality Manual is to spread the Quality Policy and to describe the form of implementing the Quality Management System, according to the requirements of the Standard ISO 9001:2000. It is applied to the design, development, implementation and maintenance of the products of the Organization of Tracers Technology (TT) and Nucleonic Control Systems (SCN). It have 9 Section: I. Introduction, II. Normative references, III. Definitions, IV. Quality Management System; V. Direction Responsibility; VI. Resources Management; VII. Products Accomplishment; VIII. Measurement, Analysis and Improvement and 7 Annex

  12. A preliminary study into performing routine tube output and automatic exposure control quality assurance using radiology information system data

    International Nuclear Information System (INIS)

    Charnock, P.; Jones, R.; Fazakerley, J.; Wilde, R.; Dunn, A. F.

    2011-01-01

    Data are currently being collected from hospital radiology information systems in the North West of the UK for the purposes of both clinical audit and patient dose audit. Could these data also be used to satisfy quality assurance (QA) requirements according to UK guidance? From 2008 to 2009, 731 653 records were submitted from 8 hospitals from the North West England. For automatic exposure control QA, the protocol from Inst. of Physics and Engineering in Medicine (IPEM) report 91 recommends that milli amperes per second can be monitored for repeatability and reproducibility using a suitable phantom, at 70-81 kV. Abdomen AP and chest PA examinations were analysed to find the most common kilo voltage used with these records then used to plot average monthly milli amperes per second with time. IPEM report 91 also recommends that a range of commonly used clinical settings is used to check output reproducibility and repeatability. For each tube, the dose area product values were plotted over time for two most common exposure factor sets. Results show that it is possible to do performance checks of AEC systems; however more work is required to be able to monitor tube output performance. Procedurally, the management system requires work and the benefits to the workflow would need to be demonstrated. (authors)

  13. MECHANISM AND REGULATION OF NONSENSE-MEDIATED MRNA DECAY (NMD, AN ESSENTIAL QUALITY CONTROL SYSTEM OF PLANTS

    Directory of Open Access Journals (Sweden)

    D. Silhavy

    2008-09-01

    Full Text Available In eukaryotic cell, various quality control mechanisms have evolved to ensure that only perfect mRNAs could be translated. Nonsense-mediated mRNA decay (NMD is a quality control system that identifies and eliminates mRNAs containing premature termination codons, thereby preventing the accumulation of potentially harmful truncated proteins. While NMD is well-characterized in yeast, in invertebrates and in mammals, plant NMD is poorly understood. In yeast and in invertebrates unusually long 3'untranslated regions (3'UTRs render an mRNA subject to NMD, while in mammals' 3'UTR located introns trigger NMD. UPF1, 2 and 3 are the key trans-acting NMD factors in yeast as well as in animals. However, in mammals, the core components of the Exon Junction Complex (Mago, Y14, eIF4A3 and MLN51 are also required for NMD. It was proposed that long 3’UTR-induced NMD is the ancient type and that it was changed to a more complex intron-based NMD in mammals. To better understand the evolution of eukaryotic NMD systems, we have studied the NMD machinery of plants, as plants are outgroup relative to fungi and animals. We have elaborated various transient assays to analyze plant NMD. Using these assays we defined the cis elements of plant NMD and characterized several trans-acting plant NMD factors. We demonstrated that two plant NMD pathways co-exist, one pathway, as yeast or invertebrate NMD systems, eliminates mRNAs with long 3'UTRs, while a distinct pathway, like mammalian NMD, degrades mRNAs harbouring 3'UTR-located introns. We showed that UPF1, UPF2, and SMG-7 are involved in both plant NMD pathways, whereas Mago and Y14 are required only for intron-based NMD. We also provide evidence that the molecular mechanism of long 3'UTR-based plant NMD resembles yeast NMD, while the intron-based NMD is similar to mammalian NMD. Moreover we have found that the SMG-7 component of plant NMD is targeted by NMD suggesting that plant NMD is autoregulated. We propose that in

  14. Fuel cycle and quality control

    International Nuclear Information System (INIS)

    Stoll, W.

    1979-01-01

    The volume of the fuel cycle is described in its economic importance and its through put, as it is envisaged for the Federal Republic of Germany. Definitions are given for quality continuing usefulness of an object and translated into quality criteria. Requirements on performance of fuel elements are defined. The way in which experimental results are translated into mass production of fuel rods, is described. The economic potential for further quality effort is derived. Future ways of development for quality control organisation and structure are outlined. (Auth.)

  15. SAQC: SNP Array Quality Control

    Directory of Open Access Journals (Sweden)

    Li Ling-Hui

    2011-04-01

    Full Text Available Abstract Background Genome-wide single-nucleotide polymorphism (SNP arrays containing hundreds of thousands of SNPs from the human genome have proven useful for studying important human genome questions. Data quality of SNP arrays plays a key role in the accuracy and precision of downstream data analyses. However, good indices for assessing data quality of SNP arrays have not yet been developed. Results We developed new quality indices to measure the quality of SNP arrays and/or DNA samples and investigated their statistical properties. The indices quantify a departure of estimated individual-level allele frequencies (AFs from expected frequencies via standardized distances. The proposed quality indices followed lognormal distributions in several large genomic studies that we empirically evaluated. AF reference data and quality index reference data for different SNP array platforms were established based on samples from various reference populations. Furthermore, a confidence interval method based on the underlying empirical distributions of quality indices was developed to identify poor-quality SNP arrays and/or DNA samples. Analyses of authentic biological data and simulated data show that this new method is sensitive and specific for the detection of poor-quality SNP arrays and/or DNA samples. Conclusions This study introduces new quality indices, establishes references for AFs and quality indices, and develops a detection method for poor-quality SNP arrays and/or DNA samples. We have developed a new computer program that utilizes these methods called SNP Array Quality Control (SAQC. SAQC software is written in R and R-GUI and was developed as a user-friendly tool for the visualization and evaluation of data quality of genome-wide SNP arrays. The program is available online (http://www.stat.sinica.edu.tw/hsinchou/genetics/quality/SAQC.htm.

  16. Quality cost system in electronics

    International Nuclear Information System (INIS)

    Denzer, H.O.

    1978-01-01

    A description is presented of a formal cost of quality system used in an electronic manufacturing facility. The system elements and reports are illustrated. Examples of the use of a quality cost system to measure quality performance and to improve product quality are included. A comparison to industry averages for quality costs is made. The paper attempts to show that the collection and use of quality costs are an aid to management and can be accompanied by improved product quality

  17. Quality control of CT systems by automated monitoring of key performance indicators: a two‐year study

    Science.gov (United States)

    Bujila, Robert; Poludniowski, Gavin; Fransson, Annette

    2015-01-01

    The purpose of this study was to develop a method of performing routine periodical quality controls (QC) of CT systems by automatically analyzing key performance indicators (KPIs), obtainable from images of manufacturers' quality assurance (QA) phantoms. A KPI pertains to a measurable or determinable QC parameter that is influenced by other underlying fundamental QC parameters. The established KPIs are based on relationships between existing QC parameters used in the annual testing program of CT scanners at the Karolinska University Hospital in Stockholm, Sweden. The KPIs include positioning, image noise, uniformity, homogeneity, the CT number of water, and the CT number of air. An application (MonitorCT) was developed to automatically evaluate phantom images in terms of the established KPIs. The developed methodology has been used for two years in clinical routine, where CT technologists perform daily scans of the manufacturer's QA phantom and automatically send the images to MonitorCT for KPI evaluation. In the cases where results were out of tolerance, actions could be initiated in less than 10 min. 900 QC scans from two CT scanners have been collected and analyzed over the two‐year period that MonitorCT has been active. Two types of errors have been registered in this period: a ring artifact was discovered with the image noise test, and a calibration error was detected multiple times with the CT number test. In both cases, results were outside the tolerances defined for MonitorCT, as well as by the vendor. Automated monitoring of KPIs is a powerful tool that can be used to supplement established QC methodologies. Medical physicists and other professionals concerned with the performance of a CT system will, using such methods, have access to comprehensive data on the current and historical (trend) status of the system such that swift actions can be taken in order to ensure the quality of the CT examinations, patient safety, and minimal disruption of service

  18. Quality assurance records system

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (IAEA Safety Series No.50-C-QA), which requires that for each nuclear power plant a system for the generation, identification, collection, indexing, filing, storing, maintenance and disposition of quality assurance records shall be established and executed in accordance with written procedures and instructions. The purpose of this Safety Guide is to provide assistance in the establishment and operation of such a system. An orderly established and maintained records system is considered to be part of the means of providing a basis for an appropriate level of confidence that the activities which affect the quality of a nuclear power plant have been performed in accordance with the specific requirements and that the required quality has been achieved and is maintained

  19. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  20. Towards an agent based traffic regulation and recommendation system for the on-road air quality control

    OpenAIRE

    Sadiq, Abderrahmane; El Fazziki, Abdelaziz; Ouarzazi, Jamal; Sadgal, Mohamed

    2016-01-01

    This paper presents an integrated and adaptive problem-solving approach to control the on-road air quality by modeling the road infrastructure, managing traffic based on pollution level and generating recommendations for road users. The aim is to reduce vehicle emissions in the most polluted road segments and optimizing the pollution levels. For this we propose the use of historical and real time pollution records and contextual data to calculate the air quality index on road networks and gen...

  1. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    2001-01-01

    The book is a collection of papers presented at the 5th International Workshop on Intelligent Statistical Quality Control in Würzburg, Germany. Contributions deal with methodology and successful industrial applications. They can be grouped in four catagories: Sampling Inspection, Statistical Process Control, Data Analysis and Process Capability Studies and Experimental Design.

  2. [A proposal for introduction of Europeristat-compatible information system aiming a unified quality control of obstetrical and perinatological care in Hungary].

    Science.gov (United States)

    Berkő, Péter

    2016-05-01

    It is a regrettable deficiency in the Hungarian healthcare that the culture and the system of quality control of cure have not been formed (except for a few subspecialties, units or wards). If hospital wards do not have a national, professionally unified and modern information system presenting the most important quantity and quality indicators of their medicinal activity annually, a stable basis for definition of future tasks is absent. The author puts forward a proposal for the establishment of the information systems for different professional fields. On the basis of experience of perinatological information system operating for over 3 decades in Borsod-Abaúj-Zemplén county, he also proposes introduction of a nationally unified, Europeristat-compatible information system following Tauffer-statistics which may serve as a uniform quality control of obstetrics and perinatological care, as well as introduction of its base, the dataform "TePERA" (Form of Obstetrics and Perinatological Care Risk).

  3. Single dose systemic acetaminophen to improve patient reported quality of recovery after ambulatory segmental mastectomy: A prospective, randomized, double-blinded, placebo controlled, clinical trial.

    Science.gov (United States)

    De Oliveira, Gildasio S; Rodes, Meghan E; Bialek, Jane; Kendall, Mark C; McCarthy, Robert J

    2017-11-15

    Few systemic drug interventions are efficacious to improve patient reported quality of recovery after ambulatory surgery. We aimed to evaluate whether a single dose systemic acetaminophen improve quality of recovery in female patients undergoing ambulatory breast surgery. We hypothesized that patients receiving a single dose systemic acetaminophen at the end of the surgical procedure would have a better global quality of postsurgical recovery compared to the ones receiving saline. The study was a prospective randomized double blinded, placebo controlled, clinical trial. Healthy female subjects were randomized to receive 1 g single dose systemic acetaminophen at the end of the surgery or the same volume of saline. The primary outcome was the Quality of Recovery 40 (QOR-40) questionnaire at 24 hours after surgery. Other data collected included opioid consumption and pain scores. Data were analyzed using group t tests and the Wilcoxon exact test. The association between opioid consumption and quality of recovery was evaluated using Spearman rho. P quality of recovery, P = .007. A single dose of systemic acetaminophen improves patient reported quality of recovery after ambulatory breast surgery. The use of systemic acetaminophen is an efficacious strategy to improve patient perceived quality of postsurgical recovery and analgesic outcomes after hospital discharge for ambulatory breast surgery. © 2017 Wiley Periodicals, Inc.

  4. Control scheme towards enhancing power quality and operational efficiency of single-phase two-stage grid-connected photovoltaic systems

    Directory of Open Access Journals (Sweden)

    Mahmoud Salem

    2015-12-01

    Full Text Available Achieving high reliable grid-connected photovoltaic (PV systems with high power quality and high operation efficiency is highly required for distributed generation units. A double grid-frequency voltage ripple is found on the dc-link voltage in single-phase photovoltaic grid-connected systems due to the unbalance of the instantaneous dc input and ac output powers. This voltage ripple has undesirable effects on the power quality and operational efficiency of the whole system. Harmonic distortion in the injected current to the grid is one of the problems caused by this double grid-frequency voltage ripple. The double grid frequency ripple propagates to the PV voltage and current which disturb the extracted maximum power from the PV array. This paper introduces intelligent solutions towards mitigate the side effects of the double grid-frequency voltage ripple on the transferred power quality and the operational efficiency of single-phase two-stage grid-connected PV system. The proposed system has three control loops: MPPT control loop, dc-link voltage control loop and inverter current control loop. Solutions are introduced for all the three control loops in the system. The current controller cancels the dc-link voltage effect on the total harmonic distortion of the output current. The dc-link voltage controller is designed to generate a ripple free reference current signal that leads to enhance the quality of the output power. Also a modified MPPT controller is proposed to optimize the extracted power from the PV array. Simulation results show that higher injected power quality is achieved and higher efficiency of the overall system is realized.

  5. Water quality diagnosis system

    International Nuclear Information System (INIS)

    Nagase, Makoto; Asakura, Yamato; Sakagami, Masaharu

    1989-01-01

    By using a model representing a relationship between the water quality parameter and the dose rate in primary coolant circuits of a water cooled reactor, forecasting for the feature dose rate and abnormality diagnosis for the water quality are conducted. The analysis model for forecasting the reactor water activity or the dose rate receives, as the input, estimated curves for the forecast Fe, Ni, Co concentration in feedwater or reactor water pH, etc. from the water quality data in the post and forecasts the future radioactivity or dose rate in the reactor water. By comparing the result of the forecast and the setting value such as an aimed value, it can be seen whether the water quality at present or estimated to be changed is satisfactory or not. If the quality is not satisfactory, it is possible to take an early countermeasure. Accordingly, the reactor water activity and the dose rate can be kept low. Further, the basic system constitution, diagnosis algorithm, indication, etc. are identical between BWR and PWR reactors, except for only the difference in the mass balance. (K.M.)

  6. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  7. Developing methods of controlling quality costs

    Directory of Open Access Journals (Sweden)

    Gorbunova A. V.

    2017-01-01

    Full Text Available The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding evaluation criteria in the quality management system of enterprises is introduced. Authors also introduce the method of controlling quality costs and propose it for the practical application, which allows them to determine useful and unnecessary costs at the existing operating plant. Implementing the proposed recommendations in the system of cost management at an enterprise will allow to improve productivity of processes operating and reduce wasted expense on the quality of the process on the basis of determining values of useful and useless costs of quality according to criteria of processes functioning in the system of quality management.

  8. [Essential guidelines for Quality Management System].

    Science.gov (United States)

    Daunizeau, A

    2013-06-01

    The guidelines describe the essential parts of the quality management system to fulfil the requirements of the standard EN ISO 15 189. It includes mainly the organisation, the definition of responsibilities, training of personnel, the document control, the quality control, identification and control of nonconformities, corrective actions, preventive actions and evaluation, as audits and the management review.

  9. Network-based production quality control

    Science.gov (United States)

    Kwon, Yongjin; Tseng, Bill; Chiou, Richard

    2007-09-01

    This study investigates the feasibility of remote quality control using a host of advanced automation equipment with Internet accessibility. Recent emphasis on product quality and reduction of waste stems from the dynamic, globalized and customer-driven market, which brings opportunities and threats to companies, depending on the response speed and production strategies. The current trends in industry also include a wide spread of distributed manufacturing systems, where design, production, and management facilities are geographically dispersed. This situation mandates not only the accessibility to remotely located production equipment for monitoring and control, but efficient means of responding to changing environment to counter process variations and diverse customer demands. To compete under such an environment, companies are striving to achieve 100%, sensor-based, automated inspection for zero-defect manufacturing. In this study, the Internet-based quality control scheme is referred to as "E-Quality for Manufacturing" or "EQM" for short. By its definition, EQM refers to a holistic approach to design and to embed efficient quality control functions in the context of network integrated manufacturing systems. Such system let designers located far away from the production facility to monitor, control and adjust the quality inspection processes as production design evolves.

  10. Quality Control - Nike.Inc

    OpenAIRE

    Walter G. Bishop

    2017-01-01

    The purpose of this paper is to present the illustration of quality control approach, which has been adopted by several organizations, in order to manage and improve their production processes. The approach is referred as total quality management (TQM). This study will discuss the implementation of TQ, within the working environment of Nike Inc. One of the major objectives behind the implementation of TQ is to reduce or completely eliminate potential errors and flaws, within the manufacturing...

  11. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    Energy Technology Data Exchange (ETDEWEB)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A. [Valencia (Spain)

    1999-07-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  12. Quality Control in the Dosimetric System of the Personnel Dosimetry Service of the Spanish National Health Service

    International Nuclear Information System (INIS)

    Casal, E.; Gil, J.A.; Roig, F.; Soriano, A.

    1999-01-01

    The main operating and quality control procedures implemented at the Centro Nacional de Dosimetria (CND) of the Spanish National Health Service to ensure the acceptance of the dosimetry service are described. The operating procedures are routinely performed at every step, since the dosemeters are received from the manufacturer until the doses are assigned to the dosimetric history and their main aim is to ensure the traceability of the doses. They make use of control and background dosemeters and frequent cross reference (automatic and manual) of different sources of data. The control procedures are performed at the end of each monthly process to detect possible errors or systematic bias in the dosimetry service and include analysis of the measurements of quality control dosemeters irradiated at the CND's laboratory and randomly read. The results of this analysis since 1996 are presented. (author)

  13. Intercomparison tests and internal control samples as substantial elements of the quality control system: practical insights; Ringversuche und interne Kontrollproben als Elemente der Qualitaetssicherung: Erfahrungen aus der Praxis

    Energy Technology Data Exchange (ETDEWEB)

    Beyer, D.; Hartmann, M. [Bundesamt fuer Strahlenschutz, Berlin (Germany). Inst. fuer Angewandten Strahlenschutz

    2002-07-01

    The contribution highlights the practical experience accumulated in implementing the statutory ordinance on the monitoring of incorporated ionizing radiation by official monitoring stations, effective in Germany since 1996, focusing on the quality assurance system to be maintained by those stations. The examples used to illustrate practical aspects are: participation in intercomparison tests, sampling for internal control purposes, and the monitoring by way of excretion analyses of individuals handling alpha and beta emitters (nuclides) at their place of work. (orig./CB) [German] Im Jahre 1996 trat in Deutschland die 'Richtlinie ueber Anforderungen an Inkorporationsmessstellen' (Anforderungsrichtlinie) in Kraft. Danach werden fuer die Durchfuehrung der Inkorporationsueberwachung nur noch Messstellen amtlich anekannt, die unter anderem den dort gegebenen Anforderungen an Qualitaetssicherungsmassnahmen genuegen. Im Einzelnen betrifft dies die Teilnahme an Ringversuchen sowie die vorgeschriebenen internen Eigenkontrollen. Am Beispiel der Inkorporationsueberwachung durch Ausscheidungsanalyse, die bevorzugt beim Umgang mit alpha- und betastrahlenden Nukliden durchgefuehrt wird, werden die bisherigen Erfahrungen bei Anwendung der Anforderungsrichtlinie vorgestellt. (orig.)

  14. Water quality control program in experimental circuits

    International Nuclear Information System (INIS)

    Cegalla, Miriam A.

    1996-01-01

    The Water Quality Control Program of the Experimental Circuits visualizes studying the water chemistry of the cooling in the primary and secondary circuits, monitoring the corrosion of the systems and studying the mechanism of the corrosion products transport in the systems. (author)

  15. Control of quality in the tests of systems of containment of vehicles. Intercomparison of the results of the tests; Control de calidad en los ensayos de sistemas de contencion de vehiculos. Intercomparacion de los resultados de los ensayos

    Energy Technology Data Exchange (ETDEWEB)

    Lopez Ramos, S.

    2009-07-01

    This article tries to offer information on how Central Laboratory of Structures and Materials are made the tests for Marca N of AENOR of the systems of containment of vehicles and its control of external quality. (Author) 15 refs.

  16. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  17. Quality control in tile production

    Science.gov (United States)

    Kalviainen, Heikki A.; Kukkonen, Saku; Hyvarinen, Timo S.; Parkkinen, Jussi P. S.

    1998-10-01

    This work studies visual quality control in ceramics industry. In tile manufacturing, it is important that in each set of tiles, every single tile looks similar. For example, the tiles should have similar color and texture. Our goal is to design a machine vision system that can estimate the sufficient similarity or same appearance to the human eye. Currently, the estimation is usually done by human vision. Differing from other approaches our aim is to use accurate spectral representation of color, and we are comparing spectral features to the RGB color features. A laboratory system for color measurement is built. Experimentations with five classes of brown tiles are presented. We use chromaticity RGB features and several spectral features for classification with the k-NN classifier and with a neural network, called Self-Organizing Map. We can classify many of the tiles but there are several problems that need further investigations: larger training and test sets are needed, illuminations effects must be studied further, and more suitable spectral features are needed with more sophisticated classifiers. It is also interesting to develop further the neural approach.

  18. A fuzzy quality function deployment approach to improve a component of a supervisory control and data acquisition system

    OpenAIRE

    Cristea Ciprian; Saşa Ciprian; Cristea Maria

    2017-01-01

    Monitoring and control of electric transformer stations, frequently spread out over small or large geographical areas, are achieved with supervisory control and data acquisition (SCADA). Quality function deployment (QFD) is a valuable analyzing tool in product design and development. To solve the uncertainty or inherent imprecision in QFD, many researchers have applied the fuzzy set theory to QFD and have developed various fuzzy QFD approaches. The literature regarding applying fuzzy QFD for ...

  19. Radiological information systems: improvements in service, economy, and quality control?; Radiologische Informationssysteme: Verbesserung von Leistungserfassung, Wirtschaftlichkeit und Qualitaetssicherung?

    Energy Technology Data Exchange (ETDEWEB)

    Gross-Fengels, W. [Abt. fuer Klinische Radiologie, AK Harburg (Germany); Weber, M. [Abt. fuer Klinische Radiologie, AK Harburg (Germany)

    1997-03-01

    By means of complete service control and standardized accounting processes, radiological information systems clearly contribute to improved results. They provide the prerequisites for the establishment of expanded networks and allow comprisons with comparable institutions. The quality of patient care can be improved since, for example, the production time from referral to finished result becomes shorter. Direct access to patient and findings data from several positions is possible. Preliminary results can be viewed immediately. The patient`s history is accessible to authorized users at all times. The exact reproducibility and assignment of services leads to more clarity. By means of the information available form RIS, rapid adaptive processes can be undertaken. The system assists the to fulfill the requirements of health regulations. The above-mentioned relationships demonstrate that the EDP systems are well accepted by physicians, medical assistants, and administrators and represent an indispensable aid for solving problems. (orig.) [Deutsch] Radiologische Informationssysteme fuehren ueber komplette Leistungserfassungen und standardisierte Abrechnungsverfahren eindeutig zu einer Ergebnisverbesserung. Sie stellen die Voraussetzungen fuer den Aufbau erweiterter Netzstrukturen dar und erlauben Quervergleiche mit aehnlichen Institutionen. Die Qualitaet der Patientenversorgung laesst sich verbessern, da z.B. die `Produktionszeit` von der Anforderung bis hin zur Befundausgabe kuerzer wird. Der Zugriff zu Patienten- und Befunddaten ist unmittelbar von mehreren Stellen aus moeglich. Vorbefunde sind sofort einsehbar. Die Patientenhistorie ist jederzeit fuer autorisierte Anwender verfuegbar. Die exakte Reproduzierbarkeit und Zuordnung der Leistungen fuehrt zu einer hohen Transparenz. Durch die Informationen, die ueber das RIS zu erhalten sind, koennen rasche Anpassungsprozesse vorgenommen werden. Die Anlagen unterstuetzen den Anwender, den Anforderungen der GSG nachzukommen

  20. Quality control for dose calibrators

    International Nuclear Information System (INIS)

    Mendes, L.C.G.

    1984-01-01

    Nuclear medicine laboratories are required to assay samples of radioactivity to be administered to patients. Almost universally, these assays are accomplished by use of a well ionization chamber isotope calibrator. The Instituto de Radioprotecao e Dosimetria (Institute for Radiological Protection and Dosimetry) of the Comissao Nacional de Energia Nuclear (National Commission for Nuclear Energy) is carrying out a National Quality Control Programme in Nuclear Medicine, supported by the International Atomic Energy Agency. The assessment of the current needs and practices of quality control in the entire country of Brazil includes Dose Calibrators and Scintillation Cameras, but this manual is restricted to the former. Quality Control Procedures for these Instruments are described in this document together with specific recommendations and assessment of its accuracy. (author)

  1. The quality analysis system implemented by FRAGEMA

    International Nuclear Information System (INIS)

    Kopff, G.

    1988-01-01

    Systematic statistical processing of measurements and quality control data obtained through manufacturing and conformity inspection is necessary for global knowledge of the fuel quality, which is useful both to the designer and to the manufacturer. For this aim the quality control data management and processing system implemented by FRAGEMA is described and illustrated with examples of the different types of statistical quality reports which are printed out. (orig.)

  2. FLEXURAL TESTING MACHINE AS AN OFF-LINE CONTROL SYSTEM FOR QUALITY MONITORING IN THE PRODUCTION OF BENDED CERAMIC TILES

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2016-06-01

    Full Text Available The capability to bend in a controlled manner Gres Porcelain stoneware tiles passing by a very exclusive process of pyroplastic deformation opens up entirely new opportunities in utilisation of this important family of ceramics. A bended tile can be exploited in innovative applications, such as stairs, shelves, benches and even radiators, turning this element from a simple piece of furnishing in a modern functional component. But this change in functionality also requires a different approach in the quality control, both at the product and process levels, that can no longer be limited to the use of tests specified in the regulations for traditional ceramics (e.g. colour, porosity, hygroscopic .... This article describes the first device so far devised for the verification of resistance to bending of curved tiles, discussing the correct way of use. The adoption of this particular equipment as an off-line control device can represent a valid strategy for monitoring the product and process quality.

  3. Quality control of nuclear medicine instruments 1991

    International Nuclear Information System (INIS)

    1991-05-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of ''Quality Control of Nuclear Medicine Instruments'', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems. Figs and tabs

  4. Quality control of nuclear medicine instruments, 1991

    International Nuclear Information System (INIS)

    1996-12-01

    This document gives detailed guidance on the quality control of various instruments used in nuclear medicine. A first preliminary document was drawn up in 1979. A revised and extended version, incorporating recommended procedures, test schedules and protocols was prepared in 1982. The first edition of 'Quality Control of Nuclear Medicine Instruments', IAEA-TECDOC-317, was printed in late 1984. Recent advances in the field of nuclear medicine imaging made it necessary to add a chapter on Camera-Computer Systems and another on SPECT Systems

  5. Frontiers in statistical quality control

    CERN Document Server

    Wilrich, Peter-Theodor

    1997-01-01

    Like the preceding volumes, and met with a lively response, the present volume is collecting contributions stressed on methodology or successful industrial applications. The papers are classified under four main headings: sampling inspection, process quality control, data analysis and process capability studies and finally experimental design.

  6. Standardization of tests of quality control with the aid of quality tools used in management systems of processes at the Sector of Nuclear Medicine of the University Hospital of Santa Maria, Rio Grande do Sul

    International Nuclear Information System (INIS)

    Da Cas, E.V.; Weis, G.L.; Bahunhardt, T.; Shuch, L.A.; Lopes, L.F.D.

    2009-01-01

    This work tries to standardize the tests of quality control at the Sector of Nuclear Medicine at the University Hospital of Santa Maria, using tools of the quality used in systems of management of processes such as, PDCA, brainstorming, diagram of cause and effect (Ishikawa), 5W2H, verifying list and fluxogram. The tests of quality control refer to the scintillation camera (center of rotation, intrinsic uniformity, intrinsic spatial resolution and linearity, energy resolution for each radionuclide), to the dose calibrator (accuracy, reproducibility and linearity), to the Geiger-Mueller detector (reproducibility of the detector). (author)

  7. Protein quality control in the nucleus

    DEFF Research Database (Denmark)

    Nielsen, Sofie V.; Poulsen, Esben Guldahl; Rebula, Caio A.

    2014-01-01

    to aggregate, cells have evolved several elaborate quality control systems to deal with these potentially toxic proteins. First, various molecular chaperones will seize the misfolded protein and either attempt to refold the protein or target it for degradation via the ubiquitin-proteasome system...... to be particularly active in protein quality control. Thus, specific ubiquitin-protein ligases located in the nucleus, target not only misfolded nuclear proteins, but also various misfolded cytosolic proteins which are transported to the nucleus prior to their degradation. In comparison, much less is known about...... these mechanisms in mammalian cells. Here we highlight recent advances in our understanding of nuclear protein quality control, in particular regarding substrate recognition and proteasomal degradation....

  8. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  9. [Quality system Vision 2000].

    Science.gov (United States)

    Pasini, Evasio; Pitocchi, Oreste; de Luca, Italo; Ferrari, Roberto

    2002-12-01

    A recent document of the Italian Ministry of Health points out that all structures which provide services to the National Health System should implement a Quality System according to the ISO 9000 standards. Vision 2000 is the new version of the ISO standard. Vision 2000 is less bureaucratic than the old version. The specific requests of the Vision 2000 are: a) to identify, to monitor and to analyze the processes of the structure, b) to measure the results of the processes so as to ensure that they are effective, d) to implement actions necessary to achieve the planned results and the continual improvement of these processes, e) to identify customer requests and to measure customer satisfaction. Specific attention should be also dedicated to the competence and training of the personnel involved in the processes. The principles of the Vision 2000 agree with the principles of total quality management. The present article illustrates the Vision 2000 standard and provides practical examples of the implementation of this standard in cardiological departments.

  10. Quality control of virtual wedge in a linear electron accelerator with a computerized radiography system (CR); Control de calidad de la cuna virtual en un acelerador lineal de electrones mediante un sistema de radiografia competerizada (CR)

    Energy Technology Data Exchange (ETDEWEB)

    Ordiales, J. M.; Alvarez, F. J.; Falero, B.

    2011-07-01

    For quality control of the virtual wedge there are several systems on the market as arrays of detectors or ionization chambers, linear or 2D configuration, radiochromic films or digital imaging systems incorporated in electron linear accelerators (ALE ). The present work aims at implementing a system of Computed Radiography (CR) for a routine check of the virtual wedge.

  11. The Quality Control Algorithms Used in the Creation of NASA Kennedy Space Center Lightning Protection System Towers Meteorological Database

    Science.gov (United States)

    Orcutt, John M.; Brenton, James C.

    2016-01-01

    An accurate database of meteorological data is essential for designing any aerospace vehicle and for preparing launch commit criteria. Meteorological instrumentation were recently placed on the three Lightning Protection System (LPS) towers at Kennedy Space Center (KSC) launch complex 39B (LC-39B), which provide a unique meteorological dataset existing at the launch complex over an extensive altitude range. Data records of temperature, dew point, relative humidity, wind speed, and wind direction are produced at 40, 78, 116, and 139 m at each tower. The Marshall Space Flight Center Natural Environments Branch (EV44) received an archive that consists of one-minute averaged measurements for the period of record of January 2011 - April 2015. However, before the received database could be used EV44 needed to remove any erroneous data from within the database through a comprehensive quality control (QC) process. The QC process applied to the LPS towers' meteorological data is similar to other QC processes developed by EV44, which were used in the creation of meteorological databases for other towers at KSC. The QC process utilized in this study has been modified specifically for use with the LPS tower database. The QC process first includes a check of each individual sensor. This check includes removing any unrealistic data and checking the temporal consistency of each variable. Next, data from all three sensors at each height are checked against each other, checked against climatology, and checked for sensors that erroneously report a constant value. Then, a vertical consistency check of each variable at each tower is completed. Last, the upwind sensor at each level is selected to minimize the influence of the towers and other structures at LC-39B on the measurements. The selection process for the upwind sensor implemented a study of tower-induced turbulence. This paper describes in detail the QC process, QC results, and the attributes of the LPS towers meteorological

  12. Portable water quality monitoring system

    Science.gov (United States)

    Nizar, N. B.; Ong, N. R.; Aziz, M. H. A.; Alcain, J. B.; Haimi, W. M. W. N.; Sauli, Z.

    2017-09-01

    Portable water quality monitoring system was a developed system that tested varied samples of water by using different sensors and provided the specific readings to the user via short message service (SMS) based on the conditions of the water itself. In this water quality monitoring system, the processing part was based on a microcontroller instead of Lead and Copper Rule (LCR) machines to receive the results. By using four main sensors, this system obtained the readings based on the detection of the sensors, respectively. Therefore, users can receive the readings through SMS because there was a connection between Arduino Uno and GSM Module. This system was designed to be portable so that it would be convenient for users to carry it anywhere and everywhere they wanted to since the processor used is smaller in size compared to the LCR machines. It was also developed to ease the user to monitor and control the water quality. However, the ranges of the sensors' detection still a limitation in this study.

  13. 21 CFR 111.117 - What quality control operations are required for equipment, instruments, and controls?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for equipment, instruments, and controls? 111.117 Section 111.117 Food and Drugs FOOD AND DRUG ADMINISTRATION... and Process Control System: Requirements for Quality Control § 111.117 What quality control operations...

  14. Quality assurance and quality control in mammography: A review

    International Nuclear Information System (INIS)

    BenComo, Jose A.

    2000-01-01

    A mammogram is among the most technically demanding radiographic procedures. The early detection of breast cancer relies on the radiologist's ability to perceive subtle changes in the image that are only perceptible with high-quality imaging. Early detection of breast cancer is only as reliable as the mammogram with which a diagnosis is made, and a mammogram is only as accurate as the system that produces it. A quality assurance (QA) program maximizes the likelihood that the mammographic images will provide adequate diagnostic information for the least possible radiation exposure and cost to the patient. The QA program monitors each phase of operation of the imaging facility beginning with the request for an examination and ending with the interpretation of the referring physician and ensures that the imaging equipment used for the examination will yield the information desired. Because image quality is the most important technical aspect of mammography, this review summarizes the most important QA and quality control issues

  15. Quality Assurance/Quality Control Jobs

    Science.gov (United States)

    Fanslau, Melody; Young, Janelle

    The production of a quality and safe food product is essential to the success of any food manufacturing facility. Because of this great importance, a career in quality can be extremely rewarding. Without happy customers willing to buy a product, a company would not be able to survive. Quality issues such as foreign objects, spoiled or mislabeled product, failure to meet net weight requirements, or a recall can all turn customers away from buying a product. The food industry is a customer-driven market in which some consumers are brand loyal based on a history of high quality or in which a single bad experience with a product will turn them away for a lifetime. With this said, the main role of a quality department is to help ensure that quality issues such as these are eliminated or kept to a minimum to maintain or increase the number of customers purchasing their product.

  16. [Establishment of Quality Control System of Nucleic Acid Detection for Ebola Virus in Sierra Leone-China Friendship Biological Safety Laboratory].

    Science.gov (United States)

    Wang, Qin; Zhang, Yong; Nie, Kai; Wang, Huanyu; Du, Haijun; Song, Jingdong; Xiao, Kang; Lei, Wenwen; Guo, Jianqiang; Wei, Hejiang; Cai, Kun; Wang, Yanhai; Wu, Jiang; Gerald, Bangura; Kamara, Idrissa Laybohr; Liang, Mifang; Wu, Guizhen; Dong, Xiaoping

    2016-03-01

    The quality control process throughout the Ebola virus nucleic acid detection in Sierra Leone-China Friendship Biological Safety Laboratory (SLE-CHN Biosafety Lab) was described in detail, in order to comprehensively display the scientific, rigorous, accurate and efficient practice in detection of Ebola virus of first batch detection team in SLE-CHN Biosafety Lab. Firstly, the key points of laboratory quality control system was described, including the managements and organizing, quality control documents and information management, instrument, reagents and supplies, assessment, facilities design and space allocation, laboratory maintenance and biosecurity. Secondly, the application of quality control methods in the whole process of the Ebola virus detection, including before the test, during the test and after the test, was analyzed. The excellent and professional laboratory staffs, the implementation of humanized management are the cornerstone of the success; High-level biological safety protection is the premise for effective quality control and completion of Ebola virus detection tasks. And professional logistics is prerequisite for launching the laboratory diagnosis of Ebola virus. The establishment and running of SLE-CHN Biosafety Lab has landmark significance for the friendship between Sierra Leone and China, and the lab becomes the most important base for Ebola virus laboratory testing in Sierra Leone.

  17. Control of quality in mammography

    International Nuclear Information System (INIS)

    2006-10-01

    The present protocol of quality control/quality assurance in mammography is the result of the work of two regional projects realised in Latin America within the frame of ARCAL with the support of the IAEA. The first is ARCAL LV (RLA/6/043) project on quality assurance/quality control in mammography studies which analysed the present situation of the mammography in the member countries of the project which include: Bolivia, Colombia, Costa Rica, Cuba, El Salvador, Guatemala, Nicaragua, Panama, Paraguay, Peru, Dominican Republic and Republic of Venezuela and the second is ARCAL XLIX (RLA/9/035) project, whose members were Brazil, Colombia, Cuba, Chile, Mexico, and Peru, worked the application of Basic Safety Standards for the protection against ionising radiation with the aim to improve radiation protection in X-ray diagnosis medical practices through the implementation of the Basic Safety Standards (BSS) related to x-ray diagnosis in selected hospitals located in each country involved in the project. The work of both projects had been consolidated and harmonized in the present publication

  18. quality control of the radiopharmaceuticals

    International Nuclear Information System (INIS)

    Boukarra, Hajer; Boubakri, Rania

    2006-01-01

    This work is a contribution to the quality control of two radio pharmaceutical. Our study was carried out on the rat. These results enable us to draw the following conclusions: - the control of the purity of the cerebral tracers (Cytectrenes) is carried out by HPLC by using a detector of radioactivity which offers a great sensitivity. - the radiochemical output of marking of Kit MDP determined by thin chromatography of layer is 99%. - The study of the biodistribution in the rat showed an affinity raised for the feet bone. - These results are in conformity with the European pharmacopoeia, which enables us to require a marketing authorization. (author)

  19. Radiation measurements and quality control

    International Nuclear Information System (INIS)

    McLaughlin, W.L.

    1977-01-01

    Accurate measurements are essential to research leading to a successful radiation process and to the commissioning of the process and the facility. On the other hand, once the process is in production, the importance to quality control of measuring radiation quantities (i.e., absorbed dose, dose rate, dose distribution) rather than various other parameters of the process (i.e. conveyor speed, dwell time, radiation field characteristics, product dimensions) is not clearly established. When the safety of the product is determined by the magnitude of the administered dose, as in radiation sterilization, waste control, or food preservation, accuracy and precision of the measurement of the effective dose are vital. Since physical dose measurements are usually simpler, more reliable and reproducible than biological testing of the product, there is a trend toward using standardized dosimetry for quality control of some processes. In many industrial products, however, such as vulcanized rubber, textiles, plastics, coatings, films, wire and cable, the effective dose can be controlled satisfactorily by controlling process variables or by product testing itself. In the measurement of radiation dose profiles by dosimetry, it is necessary to have suitable dose meter calibrations, to account for sources of error and imprecision, and to use correct statistical procedures in specifying dwell times or conveyor speeds and source and product parameters to achieve minimum and maximum doses within specifications. (author)

  20. Quality control of 11C-carfentanil

    International Nuclear Information System (INIS)

    Zhang Xiaojun; Zhang Jinming; Tian Jiahe; Xiang Xiaohui

    2013-01-01

    To study the quality control of 11 C-Carfentanil injection, physical, chemical and biological identification were used. The chemical and radiochemical purity of 11 C-Carfentanil Injection were detected by HPLC and Flower Count system; measured the quantity of product by LC-MS, specific activity was calculated later; The PTS was used to detect endotoxin, and other quality control methods were put up to guarantee the security of its clinical application. The produce appeared colorless and transparent, the radiochemical purity was more than 98%, content of the endotoxin was less than 5 EU/mL. The result showed that 11 C-Carfentanil injection had fulfilled pharmaceutical quality control request and could be applied safely to animal experiment and clinical diagnosis. (authors)

  1. Design and implementation of a control system to improve the quality of the combustion gases in the fire-tube boiler of 5 BHP

    Directory of Open Access Journals (Sweden)

    Carlos Alfredo Pérez Albán

    2016-06-01

    Full Text Available The goal of this paper is the design and implementation of a system for controlling the quality of the combustion gases in a fire-tube boiler of 5 BHP. Based on the percentage of O2 present in the combustion gases, measured by a lambda sensor, the percentage of CO2 emitted into the atmosphere is determined. PID proportional control is responsible for the automatic regulation of the entry of air to the boiler by an actuator, according to the percentage of the oxygen concentration in the combustion gases. The control system has an HMI display and a modular PLC. The results achieved ensure pollutant gases emissions within the parameters established by current environmental standards, achieving the required quality of combustion gases and reducing the fuel consumption of the boiler.

  2. Control cards as a statistical quality control resource

    Directory of Open Access Journals (Sweden)

    Aleksandar Živan Drenovac

    2013-02-01

    Full Text Available Normal 0 false false false MicrosoftInternetExplorer4 This paper proves that applying of statistical methods can significantly contribute increasing of products and services quality, as well as increasing of institutions rating. Determining of optimal, apropos anticipatory and limitary values, is based on sample`s statistical analyze. Control cards represent very confident instrument, which is simple for use and efficient for control of process, by which process is maintained in set borders. Thus, control cards can be applied in quality control of procesess of weapons and military equipment production, maintenance of technical systems, as well as for seting of standards and increasing of quality level for many other activities.

  3. Information Support of the Higher Education Quality Management System

    Directory of Open Access Journals (Sweden)

    Murat K. Baymuldin

    2013-01-01

    Full Text Available The article deals with the quality management system (QMS of a university as a combination of organizational structure, procedures, processes and resources needed to implement quality policy with the help of quality planning, management, control and improvement, the need for automated information system of the university quality management system control

  4. Program Performance Assessment System (PPAS). External reviewers' report of the consultants' meeting on analytical quality control services

    International Nuclear Information System (INIS)

    2001-01-01

    In reviewing the recommendations of previous Consultants' Meetings concerning the AQCS program, it is apparent that there has been a clear and consistent agreement on what the objectives of the AQCS activities should be. The mission statement as given in the Agency's 'Blue Book 1997-1998' states 'To assist analytical laboratories in Member States in maintaining/improving the quality of their analytical measurements, to achieve internationally acceptable levels of quality assurance and to develop and supply appropriate reference standards to achieve these objectives'. In concert with this mission statement, the consultants have endorsed an elaboration of these objectives for both the Agency' s laboratories and Member State laboratories as outlined in the 1994 Consultants' Report (KONA, HI, USA) which includes: the improvement of the reliability of results for the intended purposes; the enhancement of the comparability of results from one measurement laboratory to another; the attainment of compatibility of results in physical and chemical sciences with specific coverage of international standards for food and agriculture, human health, environment, industry, earth sciences, radiation safety, and safeguards activities; the demonstration of quality measurement systems sufficient for laboratory/analyst accreditation or acceptance, and; the establishment of traceability of radioactivity measurements and chemical analyses to the international SI system of measurements

  5. Quality control in nuclear medicine

    International Nuclear Information System (INIS)

    Kostadinova, I.

    2007-01-01

    Nuclear medicine comprises diagnosis and therapy of the diseases with radiopharmaceuticals. The ambition of all specialists in our country is their activity to reach European standards. In this connection, a Commission for external audit was formed to evaluate the quality of work in the centers of nuclear medicine. This Commission create a long-lasting programme based on the objective European criteria and the national standard of nuclear medicine, having in mind to increase quality of the work and the expert evaluation of activity in every center. The program comprises measures for quality control of instrumentation, radiopharmaceuticals, performed investigations, obtained results and the whole organization from the receiving of the isotopes to the results of the patients. The ambition is most of the centers to fulfill the requirements. As a conclusion it could be said that not only the quality of everyday nuclear medicine work is enough to increase the prestige of the specialty. It is also necessary we to have understanding expert and financial support from corresponding institutions, incl. Ministry of health for a delivery of a new, contemporary instrumentation with new possibilities. Thus it would be possible Bulgarian patients to reach the high technology apparatuses for an early functional diagnosis of the diseases and optimal treatment, which possibility have the patients from the developed countries. (author)

  6. Quality assessment of gamma camera systems

    International Nuclear Information System (INIS)

    Kindler, M.

    1985-01-01

    There are methods and equipment in nuclear medical diagnostics that allow selective visualisation of the functioning of organs or organ systems, using radioactive substances for labelling and demonstration of metabolic processes. Following a previous contribution on fundamentals and systems components of a gamma camera system, the article in hand deals with the quality characteristics of such a system and with practical quality control and its significance for clinical applications. [de

  7. Family Control and Earnings Quality

    Directory of Open Access Journals (Sweden)

    Carolina Bona Sánchez

    2007-06-01

    Full Text Available El trabajo analiza la relación entre el control familiar y la calidad de la información contable en un contexto en el que el tradicional conflicto de agencia entre directivos y accionistas se desplaza a la divergencia de intereses entre accionistas controladores y minoritarios. Los resultados alcanzados muestran que, en comparación con las no familiares, las empresas de naturaleza familiar divulgan unos resultados de mayor calidad, tanto en términos de menores ajustes por devengo discrecionales como de mayor capacidad de los componentes actuales del resultado para predecir los cash flows futuros. Además, el aumento en los derechos de voto en manos de la familia controladora incrementa la calidad de los resultados contables. La evidencia obtenida se muestra consistente con la presencia de un efecto reputación/vinculación a largo plazo asociado a la empresa familiar. Adicionalmente, el trabajo refleja que a medida que disminuye la divergencia entre los derechos de voto y de cash flow en manos de la familia controladora, aumenta la calidad de la información contable.PALABRAS CLAVE: derechos de voto, divergencia, empresa familiar, calidad delresultado, reputación, beneficios privados.This work examines the relationship between family control and earnings quality in a context where the salient agency problem shifts away from the classical divergence between managers and shareholders to conflicts between the controlling owner and minority shareholders. The results reveal that, compared to non-family firms, family firms reveal higher earnings quality in terms of both lower discretionary accruals and greater predictability of future cash flows. They also show a positive relationship between the level of voting rights held by the controlling family and earnings quality. The evidence is consistent with the presence of a reputation/long-term involvement effect associated with the family firm. Moreover, the work reflects that, as the divergence

  8. Physicians, radiologists, and quality control

    International Nuclear Information System (INIS)

    Payne, W.F.

    1973-01-01

    Factors involved in quality control in medical x-ray examinations to achieve the least possible exposure to the patient are discussed. It would be hoped that film quality will remain in the position of paramount importance that it must in order to achieve the greatest amount of diagnostic information on each radiographic examination. At the same time, it is hoped that this can be done by further reducing the exposure of the patient to ionizing radiation by the methods that have been discussed; namely, education of the physician, radiologist, and technologist, modern protective equipment and departmental construction, efficient collimation whether automatic or manual, calibration and output measurement of the radiographic and fluoroscopic units, ongoing programs of education within each department of radiographic facility, film badge monitoring, education of and cooperation with the nonradiologic physician, and hopefully, more intensive programs by the National and State Bureaus and Departments of Radiological Health in education and encouragement to the medical community. (U.S.)

  9. Quality control of pesticide products

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2009-07-15

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment.

  10. Quality control of pesticide products

    International Nuclear Information System (INIS)

    2009-07-01

    In light of an established need for more efficient analytical procedures, this publication, which documents the findings of an IAEA coordinated research project (CRP) on “Quality Control of Pesticide Products”, simplifies the existing protocol for pesticide analysis while simultaneously upholding existing standards of quality. This publication includes both a report on the development work done in the CRP and a training manual for use by pesticide analysis laboratories. Based on peer reviewed and internationally recognized methods published by the Association of Analytical Communities (AOAC) and the Collaborative International Pesticides Analytical Council (CIPAC), this report provides laboratories with versatile tools to enhance the analysis of pesticide chemicals and to extend the scope of available analytical repertoires. Adoption of the proposed analytical methodologies promises to reduce laboratories’ use of solvents and the time spent on reconfiguration and set-up of analytical equipment

  11. A Randomized, Double-blind, Placebo-controlled Clinical Trial Examining the Effects of Green Tea Extract on Systemic Lupus Erythematosus Disease Activity and Quality of Life.

    Science.gov (United States)

    Shamekhi, Z; Amani, R; Habibagahi, Z; Namjoyan, F; Ghadiri, Ata; Saki Malehi, A

    2017-07-01

    Antiinflammatory and immunomodulatory benefit of green tea (Camellia sinensis) in autoimmune disease has been proven in recent studies. The objective of this study was to assess the effects of green tea on disease activity and quality of life in systemic lupus erythematosus patients. A randomized controlled trial on subjects with lupus was conducted, and 68 patients in the age range of 39.1 ± 10.3 years and body mass index of 25.7 ± 5.21 kg/m 2 completed the 12-week study. Patients were randomly divided into two groups of intervention (1000 mg green tea extract, two capsules/day) and control (1000 mg of starch, two capsules/day). Main outcome measure, systemic lupus erythematosus disease activity, was assessed by the systemic lupus erythematosus disease activity index at the first and after 3 months of intervention. In addition, patient's quality of life was evaluated by short form of quality-of-life questionnaire at baseline and after 3 months. Green tea extract supplementation significantly reduced disease activity in lupus patients (p tea extracts for 12 weeks improves the systemic lupus erythematosus disease activity as well as some aspects of quality of life. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  12. X-ray quality increasing system controlled by single-chip microcomputer in single phase fluoroscopy unit

    International Nuclear Information System (INIS)

    Wang Qiaolin; Gu Hongmei

    2004-01-01

    Objective: To decrease the amount of radiation that doctor and patient receives by increasing X-ray quality. Methods: Using Single-chip Microcomputer technology, test and modulate AC(Alternating Current) from high voltage generator by IGBT. X-ray tube generates X-rays only at high energy area. Thus the amount of radiation decreases. Results: The tube current decreases remarkably and the amount of radiation that doctor and patient receives decreases effectively. Conclusion: the system can effectively decrease the amount of radiation and is widely applicable to the upgrade of all kinds of single phase X-ray units. (authors)

  13. Performance of ACCOS, an automatic crystal quality control system for the PWO crystals of the CMS calorimeter

    CERN Document Server

    Auffray, Etiennette; Freire, M; Lecoq, P; Le Goff, J M; Marcos, R; Drobychev, G Yu; Missevitch, O V; Oskine, A; Zouevski, R F; Peigneux, J P; Schneegans, M

    2001-01-01

    Nearly 80000 PWO crystals for the CMS electromagnetic calorimeter will arrive at CERN/Geneva and INFN-ENEA/Rome between now and year 2004. The stringent specifications on their dimensions and optical quality have to be verified prior to their formal acceptation. Automatic systems for measuring the critical parameters of each crystal and recording them in a database have been designed and constructed. The first machine is now in stable operation at CERN. In this note, the performance of each instrument, based on the measurements on ~1000 pre-production crystals, is analysed in terms of stability and compared to the results of conventional benches. (9 refs).

  14. Quality monitored distributed voting system

    Science.gov (United States)

    Skogmo, David

    1997-01-01

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  15. 40 CFR 51.359 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 2 2010-07-01 2010-07-01 false Quality control. 51.359 Section 51.359....359 Quality control. Quality control measures shall insure that emission testing equipment is calibrated and maintained properly, and that inspection, calibration records, and control charts are...

  16. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  17. Distributed sensor architecture for intelligent control that supports quality of control and quality of service.

    Science.gov (United States)

    Poza-Lujan, Jose-Luis; Posadas-Yagüe, Juan-Luis; Simó-Ten, José-Enrique; Simarro, Raúl; Benet, Ginés

    2015-02-25

    This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS) parameters and the optimization of control using Quality of Control (QoC) parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS) communication standard as proposed by the Object Management Group (OMG). As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl) has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC) system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  18. Distributed Sensor Architecture for Intelligent Control that Supports Quality of Control and Quality of Service

    Directory of Open Access Journals (Sweden)

    Jose-Luis Poza-Lujan

    2015-02-01

    Full Text Available This paper is part of a study of intelligent architectures for distributed control and communications systems. The study focuses on optimizing control systems by evaluating the performance of middleware through quality of service (QoS parameters and the optimization of control using Quality of Control (QoC parameters. The main aim of this work is to study, design, develop, and evaluate a distributed control architecture based on the Data-Distribution Service for Real-Time Systems (DDS communication standard as proposed by the Object Management Group (OMG. As a result of the study, an architecture called Frame-Sensor-Adapter to Control (FSACtrl has been developed. FSACtrl provides a model to implement an intelligent distributed Event-Based Control (EBC system with support to measure QoS and QoC parameters. The novelty consists of using, simultaneously, the measured QoS and QoC parameters to make decisions about the control action with a new method called Event Based Quality Integral Cycle. To validate the architecture, the first five Braitenberg vehicles have been implemented using the FSACtrl architecture. The experimental outcomes, demonstrate the convenience of using jointly QoS and QoC parameters in distributed control systems.

  19. Closed-Loop System Identification Experience for Flight Control Law and Flying Qualities Evaluation of a High Performance Fighter Aircraft

    Science.gov (United States)

    Murphy, Patrick C.

    1999-01-01

    This paper highlights some of the results and issues associated with estimating models to evaluate control law design methods and design criteria for advanced high performance aircraft. Experimental fighter aircraft such as the NASA High Alpha Research Vehicle (HARV) have the capability to maneuver at very high angles of attack where nonlinear aerodynamics often predominate. HARV is an experimental F/A-18, configured with thrust vectoring and conformal actuated nose strakes. Identifying closed-loop models for this type of aircraft can be made difficult by nonlinearities and high-order characteristics of the system. In this paper only lateral-directional axes are considered since the lateral-directional control law was specifically designed to produce classical airplane responses normally expected with low-order, rigid-body systems. Evaluation of the control design methodology was made using low-order equivalent systems determined from flight and simulation. This allowed comparison of the closed-loop rigid-body dynamics achieved in flight with that designed in simulation. In flight, the On Board Excitation System was used to apply optimal inputs to lateral stick and pedals at five angles of attack: 5, 20, 30, 45, and 60 degrees. Data analysis and closed-loop model identification were done using frequency domain maximum likelihood. The structure of the identified models was a linear state-space model reflecting classical 4th-order airplane dynamics. Input time delays associated with the high-order controller and aircraft system were accounted for in data preprocessing. A comparison of flight estimated models with small perturbation linear design models highlighted nonlinearities in the system and indicated that the estimated closed-loop rigid-body dynamics were sensitive to input amplitudes at 20 and 30 degrees angle of attack.

  20. Analysis of the acceptance procedure and quality control a virtual simulation system; Analisis del procedimiento de aceptacion y control de calidad de un sistema de simulacion virtual

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez Ruiz, C.; Pedrero de Aristizabal, D.; Jimenez Rojas, R.; Garcia Hernandez, M. J.; Ruiz Galan, G.; Ayala Lazaro, R.; Garcia Marcos, R.

    2011-07-01

    Acceptance has been made, determining the reference state, commissioning and implementation of control protocol virtual simulation system consists of an image acquisition unit of computerized tomography (CT), an independent external location laser locator and a simulation module associated with the existing scheduler for clinical dosimetry in radiotherapy. This paper summarizes the path followed in this process, together with the established procedure for periodic monitoring and analysis system of the results obtained in the two years of clinical and control.

  1. A Comparison of Power Quality Controllers

    Directory of Open Access Journals (Sweden)

    Petr Černek

    2012-01-01

    Full Text Available This paper focuses on certain types of FACTS (Flexibile AC Transmission System controllers, which can be used for improving the power quality at the point of connection with the power network. It focuses on types of controllers that are suitable for use in large buildings, rather than in transmission networks. The goal is to compare the features of the controllers in specific tasks, and to clarify which solution is best for a specific purpose. It is in some cases better and cheaper to use a combination of controllers than a single controller. The paper also presents the features of a shunt active harmonic compensator, which is a very modern power quality controller that can be used in many cases, or in combination with other controllers. The comparison was made using a matrix diagram that, resulted from mind mapsand other analysis tools. The paper should help engineers to choose the best solution for improving the power quality in a specific power network at distribution level.

  2. Information System Quality Assessment Methods

    OpenAIRE

    Korn, Alexandra

    2014-01-01

    This thesis explores challenging topic of information system quality assessment and mainly process assessment. In this work the term Information System Quality is defined as well as different approaches in a quality definition for different domains of information systems are outlined. Main methods of process assessment are overviewed and their relationships are described. Process assessment methods are divided into two categories: ISO standards and best practices. The main objective of this w...

  3. The reliability-quality relationship for quality systems and quality risk management.

    Science.gov (United States)

    Claycamp, H Gregg; Rahaman, Faiad; Urban, Jason M

    2012-01-01

    Engineering reliability typically refers to the probability that a system, or any of its components, will perform a required function for a stated period of time and under specified operating conditions. As such, reliability is inextricably linked with time-dependent quality concepts, such as maintaining a state of control and predicting the chances of losses from failures for quality risk management. Two popular current good manufacturing practice (cGMP) and quality risk management tools, failure mode and effects analysis (FMEA) and root cause analysis (RCA) are examples of engineering reliability evaluations that link reliability with quality and risk. Current concepts in pharmaceutical quality and quality management systems call for more predictive systems for maintaining quality; yet, the current pharmaceutical manufacturing literature and guidelines are curiously silent on engineering quality. This commentary discusses the meaning of engineering reliability while linking the concept to quality systems and quality risk management. The essay also discusses the difference between engineering reliability and statistical (assay) reliability. The assurance of quality in a pharmaceutical product is no longer measured only "after the fact" of manufacturing. Rather, concepts of quality systems and quality risk management call for designing quality assurance into all stages of the pharmaceutical product life cycle. Interestingly, most assays for quality are essentially static and inform product quality over the life cycle only by being repeated over time. Engineering process reliability is the fundamental concept that is meant to anticipate quality failures over the life cycle of the product. Reliability is a well-developed theory and practice for other types of manufactured products and manufacturing processes. Thus, it is well known to be an appropriate index of manufactured product quality. This essay discusses the meaning of reliability and its linkages with quality

  4. Development of the quality control system of the readout electronics for the large size telescope of the Cherenkov Telescope Array observatory

    Energy Technology Data Exchange (ETDEWEB)

    Konno, Y.; Kubo, H.; Masuda, S. [Department of Physics, Graduate School of Science, Kyoto University, Kyoto (Japan); Paoletti, R.; Poulios, S. [SFTA Department, Physics Section, University of Siena and INFN, Siena (Italy); Rugliancich, A., E-mail: andrea.rugliancich@pi.infn.it [SFTA Department, Physics Section, University of Siena and INFN, Siena (Italy); Saito, T. [Department of Physics, Graduate School of Science, Kyoto University, Kyoto (Japan)

    2016-07-11

    The Cherenkov Telescope Array (CTA) is the next generation VHE γ-ray observatory which will improve the currently available sensitivity by a factor of 10 in the range 100 GeV to 10 TeV. The array consists of different types of telescopes, called large size telescope (LST), medium size telescope (MST) and small size telescope (SST). A LST prototype is currently being built and will be installed at the Observatorio Roque de los Muchachos, island of La Palma, Canary islands, Spain. The readout system for the LST prototype has been designed and around 300 readout boards will be produced in the coming months. In this note we describe an automated quality control system able to measure basic performance parameters and quickly identify faulty boards. - Highlights: • The Dragon Board is part of the DAQ of the LST Cherenkov telescope prototype. • We developed an automated quality control system for the Dragon Board. • We check pedestal, linearity, pulse shape and crosstalk values. • The quality control test can be performed on the production line.

  5. Automatic control systems engineering

    International Nuclear Information System (INIS)

    Shin, Yun Gi

    2004-01-01

    This book gives descriptions of automatic control for electrical electronics, which indicates history of automatic control, Laplace transform, block diagram and signal flow diagram, electrometer, linearization of system, space of situation, state space analysis of electric system, sensor, hydro controlling system, stability, time response of linear dynamic system, conception of root locus, procedure to draw root locus, frequency response, and design of control system.

  6. Physician Quality Reporting System

    Data.gov (United States)

    U.S. Department of Health & Human Services — PQRS is a reporting program that uses a combination of incentive payments and negative payment adjustments to promote reporting of quality information by eligible...

  7. Hydrological Controls on Dissolved Organic Matter Quality and Export in a Coastal River System in Southeastern USA

    Science.gov (United States)

    Bhattacharya, R.; Osburn, C. L.

    2017-12-01

    Dissolved organic matter (DOM) exported from river catchments can influence the biogeochemical processes in coastal environments with implications for water quality and carbon budget. High flow conditions are responsible for most DOM export ("pulses") from watersheds, and these events reduce DOM transformation and production by "shunting" DOM from river networks into coastal waters: the Pulse-Shunt Concept (PSC). Subsequently, the source and quality of DOM is also expected to change as a function of river flow. Here, we used stream dissolved organic carbon concentrations ([DOC]) along with DOM optical properties, such as absorbance at 350 nm (a350) and fluorescence excitation and emission matrices modeled by parallel factor analysis (PARAFAC), to characterize DOM source, quality and fluxes under variable flow conditions for the Neuse River, a coastal river system in the southeastern US. Observations were made at a flow gauged station above head of tide periodically between Aug 2011 and Feb 2013, which captured low flow periods in summer and several high flow events including Hurricane Irene. [DOC] and a350 were correlated and varied positively with river flow, implying that a large portion of the DOM was colored, humic and flow-mobilized. During high flow conditions, PARAFAC results demonstrated the higher influx of terrestrial humic DOM, and lower in-stream phytoplankton production or microbial degradation. However, during low flow, DOM transformation and production increased in response to higher residence times and elevated productivity. Further, 70% of the DOC was exported by above average flows, where 3-4 fold increases in DOC fluxes were observed during episodic events, consistent with PSC. These results imply that storms dramatically affects DOM export to coastal waters, whereby high river flow caused by episodic events primarily shunt terrestrial DOM to coastal waters, whereas low flow promotes in-stream DOM transformation and amendment with microbial DOM.

  8. Quality and reliability control on assemblies

    International Nuclear Information System (INIS)

    Mueller, H.

    1976-01-01

    Taking as an example electronic assemblies in printed circuit board engineering, quality control during manufacture is dealt with. After giving a survey of four phases of quality and reliability control, some specific methods of quality control are dealt with by means of a flowchart, and by some examples the necessity and the success of these measures are shown. (RW) [de

  9. 7 CFR 930.44 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 930.44 Section 930.44 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Control § 930.44 Quality control. (a) Quality standards. The Board may establish, with the approval of the...

  10. 33 CFR 385.21 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Quality control. 385.21 Section... Processes § 385.21 Quality control. (a) The Corps of Engineers and the non-Federal sponsor shall prepare a quality control plan, in accordance with applicable Corps of Engineers regulations, for each product that...

  11. 7 CFR 981.42 - Quality control.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Quality control. 981.42 Section 981.42 Agriculture Regulations of the Department of Agriculture (Continued) AGRICULTURAL MARKETING SERVICE (Marketing Agreements... Regulating Handling Quality Control § 981.42 Quality control. (a) Incoming. Except as provided in this...

  12. Quality control beam of radiation through imaging system using a flat panel (ILD); Control de calidad de haz de radiacion mediante un sistema de imagen de panel plano (EPID)

    Energy Technology Data Exchange (ETDEWEB)

    Benitez Serrano, J. A.; Gomez Barrado, A.; Sanchez-Reyes, A.

    2013-07-01

    The daily quality checks of the accelerator include, among others, checks of the daily calibration, symmetry and uniformity of the radiation beam. Usually verification systems daily are used for this purpose, which employ arrays of detectors of solid-state or ionization chambers. This paper intends to carry out the control of quality through the irradiation of a number of fields in the portal imaging system and its subsequent analysis in software's own creation, as well as the comparison of results with the daily verification system. (Author)

  13. Association between product quality control and process quality control of bulk milk

    NARCIS (Netherlands)

    Velthuis, A.; Asseldonk, van M.A.P.M.

    2010-01-01

    Assessment of dairy-milk quality is based on product quality control (testing bulk-milk samples) and process quality control (auditing dairy farms). It is unknown whether process control improves product quality. To quantify possible association between product control and process control a

  14. Activity and participation, quality of life and user satisfaction outcomes of environmental control systems and smart home technology: a systematic review.

    Science.gov (United States)

    Brandt, Ase; Samuelsson, Kersti; Töytäri, Outi; Salminen, Anna-Liisa

    2011-01-01

    To examine activity and participation, quality of life, and user satisfaction outcomes of environmental control systems (ECSs) and smart home technology (SHT) interventions for persons with impairments. A systematic review. Seventeen databases, three conference proceedings, and two journals were searched without language or study design restrictions covering the period January 1993 - June 2009. Reviewers selected studies, extracted data, and assessed the methodological quality independently. Of 1739 studies identified, five effect studies and six descriptive studies were included. One study was on SHT and the remainder on ECS; functionalities were overlapping. The studies varied in most aspects, and no synthesis could be drawn. However, ECS/SHT tended to increase study participants' independence, instrumental activities of daily living, socialising, and quality of life. Two studies showed high user satisfaction. The level of evidence was regarded as low, mainly due to small study sizes, lacking confounder control, and a majority of descriptive studies. Due to few and small studies and study diversity, it was not possible to determine whether ECS/SHT have positive outcomes for persons with impairment, even though the technologies seem to be promising. High quality outcomes studies such as randomised controlled trials, when feasible, and large longitudinal multi-centre studies are required.

  15. Precision digital control systems

    Science.gov (United States)

    Vyskub, V. G.; Rozov, B. S.; Savelev, V. I.

    This book is concerned with the characteristics of digital control systems of great accuracy. A classification of such systems is considered along with aspects of stabilization, programmable control applications, digital tracking systems and servomechanisms, and precision systems for the control of a scanning laser beam. Other topics explored are related to systems of proportional control, linear devices and methods for increasing precision, approaches for further decreasing the response time in the case of high-speed operation, possibilities for the implementation of a logical control law, and methods for the study of precision digital control systems. A description is presented of precision automatic control systems which make use of electronic computers, taking into account the existing possibilities for an employment of computers in automatic control systems, approaches and studies required for including a computer in such control systems, and an analysis of the structure of automatic control systems with computers. Attention is also given to functional blocks in the considered systems.

  16. Quality and Control of Water Vapor Winds

    Science.gov (United States)

    Jedlovec, Gary J.; Atkinson, Robert J.

    1996-01-01

    Water vapor imagery from the geostationary satellites such as GOES, Meteosat, and GMS provides synoptic views of dynamical events on a continual basis. Because the imagery represents a non-linear combination of mid- and upper-tropospheric thermodynamic parameters (three-dimensional variations in temperature and humidity), video loops of these image products provide enlightening views of regional flow fields, the movement of tropical and extratropical storm systems, the transfer of moisture between hemispheres and from the tropics to the mid- latitudes, and the dominance of high pressure systems over particular regions of the Earth. Despite the obvious larger scale features, the water vapor imagery contains significant image variability down to the single 8 km GOES pixel. These features can be quantitatively identified and tracked from one time to the next using various image processing techniques. Merrill et al. (1991), Hayden and Schmidt (1992), and Laurent (1993) have documented the operational procedures and capabilities of NOAA and ESOC to produce cloud and water vapor winds. These techniques employ standard correlation and template matching approaches to wind tracking and use qualitative and quantitative procedures to eliminate bad wind vectors from the wind data set. Techniques have also been developed to improve the quality of the operational winds though robust editing procedures (Hayden and Veldon 1991). These quality and control approaches have limitations, are often subjective, and constrain wind variability to be consistent with model derived wind fields. This paper describes research focused on the refinement of objective quality and control parameters for water vapor wind vector data sets. New quality and control measures are developed and employed to provide a more robust wind data set for climate analysis, data assimilation studies, as well as operational weather forecasting. The parameters are applicable to cloud-tracked winds as well with minor

  17. Water quality and emergy evaluation of two freshwater aquacultural systems for eutrophic water in the Controlling by Biological Chains

    Science.gov (United States)

    Xi, L. M.; Liu, C. Q.; Liu, D. F.; Huang, W. L.; Sun, Y.

    2017-08-01

    According to the ecological restoration theory, this experiment establishes aquaculture systems controlled by biological chains in both Xiaoxidian area and Dujiadian area of Baiyangdian Lake separately in order to improve the environment and bring economic benefits. The appearance of Emergy Theory provides a new method for the quantitative analysis of ecological economic system. Based on the analysis of Emergy Theory, this thesis compares the eco-economic systems under different polyculture models between Xiaoxidian area and Dujiadian area. The result demonstrates that Xiaoxidian ecological system is of high Emergy Transformity with higher emergy output and economic income per unit area compared with Dujiadian area. While Dujiadian area has higher Emergy Yield Rate and lower Environment Load Rate. So Dujiadian area is more sustainable due to the overload non-renewable energy of Xiaoxidian area devoted by human. Therefore, it will be better if we adjust and optimize the management of aquaculture system in Xiaoxidian area in order to find a stable equilibrium point between environmental sustainability and economic benefits.

  18. BSF control system

    International Nuclear Information System (INIS)

    Irie, Y.; Ishii, K.; Ninomiya, S.; Sasaki, H.; Sakai, I.

    1982-08-01

    The booster synchrotron utilization facility (BSF) is a facility which utilizes the four fifths of available beam pulses from the KEK booster synchrotron. The BSF control system includes the beam line control, interactions with the PS central control room and the experimental facilities, and the access control system. A brief description of the various components in the control system is given. (author)

  19. Automatically controlled training systems

    International Nuclear Information System (INIS)

    Milashenko, A.; Afanasiev, A.

    1990-01-01

    This paper reports that the computer system for NPP personnel training was developed for training centers in the Soviet Union. The system should be considered as the first step in training, taking into account that further steps are to be devoted to part-task and full scope simulator training. The training room consists of 8-12 IBM PC/AT personal computers combined into a network. A trainee accesses the system in a dialor manner. Software enables the instructor to determine the trainee's progress in different subjects of the program. The quality of any trainee preparedness may be evaluated by Knowledge Control operation. Simplified dynamic models are adopted for separate areas of the program. For example, the system of neutron flux monitoring has a dedicated model. Currently, training, requalification and support of professional qualifications of nuclear power plant operators is being emphasized. A significant number of emergency situations during work are occurring due to operator errors. Based on data from September-October 1989, more than half of all unplanned drops in power and stoppages of power plants were due to operator error. As a comparison, problems due to equipment malfunction accounted for no more than a third of the total. The role of personnel, especially of the operators, is significant during normal operations, since energy production costs as well as losses are influenced by the capability of the staff. These facts all point to the importance of quality training of personnel

  20. Implementation of the program of quality control of the system on-board imager of varian: initial assessment; Puesta en marcha del programa de control de calidad del sistema on-board imager de varian: evaluacion inicial

    Energy Technology Data Exchange (ETDEWEB)

    Ortega Martin, I.; Ruiz Morales, C.; Lopez Sanchez, F.; Tobarra Gonzalez, B. M.

    2013-07-01

    This work aims to present evidence that are part of our quality control system on-board Imager of Varian, elaborated from recommendations and national and international protocols, as well as a first assessment of the results obtained to date. (Author)

  1. Control system design method

    Science.gov (United States)

    Wilson, David G [Tijeras, NM; Robinett, III, Rush D.

    2012-02-21

    A control system design method and concomitant control system comprising representing a physical apparatus to be controlled as a Hamiltonian system, determining elements of the Hamiltonian system representation which are power generators, power dissipators, and power storage devices, analyzing stability and performance of the Hamiltonian system based on the results of the determining step and determining necessary and sufficient conditions for stability of the Hamiltonian system, creating a stable control system based on the results of the analyzing step, and employing the resulting control system to control the physical apparatus.

  2. FFTF control system experience

    International Nuclear Information System (INIS)

    Warrick, R.P.

    1981-01-01

    The FFTF control systems provide control equipment for safe and efficient operation of the plant. For convenience, these systems will be divided into three parts for discussions: (1) Plant Protection System (PPS); (2) Plant Control System (PCS); and (3) General Observations. Performance of each of these systems is discussed

  3. Design an Indoor Air Quality Controller Based on LPC2478

    Directory of Open Access Journals (Sweden)

    Shi Shuheng

    2014-07-01

    Full Text Available Indoor air quality is very important to our lives, because we spend most of our time indoor. In order to improve the air quality of indoor, this paper designs an indoor environment quality monitoring and controlling system based on ARM microcontroller LPC2478. It will do a real-time monitoring work for detecting the indoor environmental factors and comprehensively evaluate its air quality level. While the indoor air quality status is "poor", this intelligent system will automatically start the heat exchange ventilator for indoor environmental quality improvement. The results compared to traditional natural ventilation method show the better performance of proposed system.

  4. Quality control guarantees the safety of radiotherapy

    International Nuclear Information System (INIS)

    Aaltonen, P.

    1994-01-01

    While radiotherapy equipment has seen some decisive improvements in the last few decades, the technology has also become more complicated. The advanced equipment produces increasingly good treatment results, but the condition of the equipment must be controlled efficiently so as to eliminate any defects that might jeopardise patient safety. The quality assurance measures that are taken to show that certain equipment functions as required are known as quality control. The advanced equipment and stricter requirements set for the precision of radiotherapy have meant that more attention must be paid to quality control. The present radiation legislation stipulates that radiotherapy equipment must undergo regular quality control. The implementation of the quality control is supervised by the Finnish Centre for Radiation and Nuclear Safety (STUK). Hospitals carry out quality control in accordance with a programme approved by STUK, and STUK inspectors periodically visit hospitals to check the results of quality control. (orig.)

  5. Control of Bank Consolidated Financial Statements Quality

    Directory of Open Access Journals (Sweden)

    Margarita S. Ambarchyan

    2013-01-01

    Full Text Available The author presents the multiple linear regression model of bank consolidated financial statements quality. The article considers six characteristics that can be used to estimate the level of bank consolidated financial statements quality. The multiple linear regression model was developed, using the results of point-based system of consolidated financial statements of thirty European bank and financial groups on the basis of the developed characteristics. The author offers to use the characteristic significance factor in the process of consolidated financial statements appraisal by points. The constructed regression model is checked on accuracy and statistical significance. The model can be used by internal auditors and financial analytics as an instrument for bank and non-bank consolidated financial statements quality control

  6. Radiopharmaceutical quality control-Pragmatic approach

    International Nuclear Information System (INIS)

    Barbier, Y.

    1994-01-01

    The quality control must be considered in a practical manner. The radiopharmaceuticals are drugs. They must satisfy the quality assurance control. These products are then conform to Pharmacopeia. But sometimes the user must control some data especially radiochemical purity and pH value. On all the administered solutions four controls are compulsory: radionuclide identity, administered radioactivity, organoleptic character and pH

  7. Quality control of activity detectors

    International Nuclear Information System (INIS)

    Surma, M.J.

    2002-01-01

    The conditions decided on radiometric measurements quality as geometry, background, calibration etc. have been described. The testing methods for achieving high quality of radioactivity measurements using nuclear medicine instruments have been recommended

  8. Quality Controlling CMIP datasets at GFDL

    Science.gov (United States)

    Horowitz, L. W.; Radhakrishnan, A.; Balaji, V.; Adcroft, A.; Krasting, J. P.; Nikonov, S.; Mason, E. E.; Schweitzer, R.; Nadeau, D.

    2017-12-01

    As GFDL makes the switch from model development to production in light of the Climate Model Intercomparison Project (CMIP), GFDL's efforts are shifted to testing and more importantly establishing guidelines and protocols for Quality Controlling and semi-automated data publishing. Every CMIP cycle introduces key challenges and the upcoming CMIP6 is no exception. The new CMIP experimental design comprises of multiple MIPs facilitating research in different focus areas. This paradigm has implications not only for the groups that develop the models and conduct the runs, but also for the groups that monitor, analyze and quality control the datasets before data publishing, before their knowledge makes its way into reports like the IPCC (Intergovernmental Panel on Climate Change) Assessment Reports. In this talk, we discuss some of the paths taken at GFDL to quality control the CMIP-ready datasets including: Jupyter notebooks, PrePARE, LAMP (Linux, Apache, MySQL, PHP/Python/Perl): technology-driven tracker system to monitor the status of experiments qualitatively and quantitatively, provide additional metadata and analysis services along with some in-built controlled-vocabulary validations in the workflow. In addition to this, we also discuss the integration of community-based model evaluation software (ESMValTool, PCMDI Metrics Package, and ILAMB) as part of our CMIP6 workflow.

  9. Measurement system as a subsystem of the quality management system

    OpenAIRE

    Ľubica Floreková; Ján Terpák; Marcela Čarnogurská

    2006-01-01

    Each measurement system and a control principle must be based on certain facts about the system behaviour (what), operation (how) and structure (why). Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirem...

  10. 30 CFR 74.6 - Quality control.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality control. 74.6 Section 74.6 Mineral... of the CMDPSU will be maintained in production through adequate quality control procedures, MSHA and... DUST SAMPLING DEVICES Approval Requirements for Coal Mine Dust Personal Sampler Unit § 74.6 Quality...

  11. SU-G-TeP4-14: Quality Control of Treatment Planning Using Knowledge-Based Planning Across a System of Radiation Oncology Practices

    Energy Technology Data Exchange (ETDEWEB)

    Masi, K; Ditman, M; Marsh, R; Archer, P; Matuszak, M [University of Michigan, Ann Arbor, MI (United States); Dai, J [Alpena Cancer Center, Alpena, MI (United States); Huberts, M [McLaren Greater Lansing, Lansing, MI (United States); Khadija, M [Metro Health, Wyoming, MI (United States); Tatro, D [Allegiance Health, Jackson, MI (United States)

    2016-06-15

    Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned using an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target

  12. SU-G-TeP4-14: Quality Control of Treatment Planning Using Knowledge-Based Planning Across a System of Radiation Oncology Practices

    International Nuclear Information System (INIS)

    Masi, K; Ditman, M; Marsh, R; Archer, P; Matuszak, M; Dai, J; Huberts, M; Khadija, M; Tatro, D

    2016-01-01

    Purpose: There is potentially a wide variation in plan quality for a certain disease site, even for clinics located in the same system of hospitals. We have used a prostate-specific knowledge-based planning (KBP) model as a quality control tool to investigate the variation in prostate treatment planning across a network of affiliated radiation oncology departments. Methods: A previously created KBP model was applied to 10 patients each from 4 community-based clinics (Clinics A, B, C, and D). The KBP model was developed using RapidPlan (Eclipse v13.5, Varian Medical Systems) from 60 prostate/prostate bed IMRT plans that were originally planned using an in-house treatment planning system at the central institution of the community-based clinics. The dosimetric plan quality (target coverage and normal-tissue sparing) of each model-generated plan was compared to the respective clinically-used plan. Each community-based clinic utilized the same planning goals to develop the clinically-used plans that were used at the main institution. Results: Across all 4 clinics, the model-generated plans decreased the mean dose to the rectum by varying amounts (on average, 12.5, 2.6, 4.5, and 2.7 Gy for Clinics A, B, C, and D, respectively). The mean dose to the bladder also decreased with the model-generated plans (5.4, 2.3, 3.0, and 4.1 Gy, respectively). The KBP model also identified that target coverage (D95%) improvements were possible for for Clinics A, B, and D (0.12, 1.65, and 2.75%) while target coverage decreased by 0.72% for Clinic C, demonstrating potentially different trade-offs made in clinical plans at different institutions. Conclusion: Quality control of dosimetric plan quality across a system of radiation oncology practices is possible with knowledge-based planning. By using a quality KBP model, smaller community-based clinics can potentially identify the areas of their treatment plans that may be improved, whether it be in normal-tissue sparing or improved target

  13. Quality control in quantitative computed tomography

    International Nuclear Information System (INIS)

    Jessen, K.A.; Joergensen, J.

    1989-01-01

    Computed tomography (CT) has for several years been an indispensable tool in diagnostic radiology, but it is only recently that extraction of quantitative information from CT images has been of practical clinical value. Only careful control of the scan parameters, and especially the scan geometry, allows useful information to be obtained; and it can be demonstrated by simple phantom measurements how sensitive a CT system can be to variations in size, shape and position of the phantom in the gantry aperture. Significant differences exist between systems that are not manifested in normal control of image quality and general performance tests. Therefore an actual system has to be analysed for its suitability for quantitative use of the images before critical clinical applications are justified. (author)

  14. Development of sensor-less control strategies for grid connected PMSG based variable speed wind energy conversion system with improved power quality features

    Energy Technology Data Exchange (ETDEWEB)

    Chandra, A. [Quebec Univ., Montreal, PQ (Canada). Dept. of Electrical Engineering

    2010-07-01

    Interest in renewable energy sources has grown in recent years in response to concerns of increasing pollution levels and depleting fossil fuels. Among renewable energy sources, wind energy generation is the fastest growing technology and one of the most cost-effective and environmental friendly means to generate electricity from renewable sources. Modern wind turbines are ready to be deployed in large scale as a result of recent developments in wind power technology. Variable speed permanent magnet synchronous generators (PMSG) based wind energy conversion systems (WECS) are becoming more popular. The use of a permanent magnet reduces size, cost and weight of overall WECS. In addition, the absence of field winding and its excitation system avoids heat dissipation in the rotor winding, thereby improving overall efficiency of the WECS. This type of configuration is more appropriate for remote locations, particularly for off-shore wind application, where the geared doubly fed induction generator usually requires regular maintenance due to tearing-wearing in brushes, windings and gear box. This presentation discussed the development of sensor-less control strategies for grid connected PMSG based variable speed wind energy conversion system with improved power quality features. A novel adaptive network-based fuzzy inference system was used to estimate the speed and position of variable speed PMSG under fluctuating wind conditions. A novel control strategy was developed for the grid interfacing inverter incorporating power quality improvement features at point of common coupling.

  15. Wisdom Appliance Control System

    Science.gov (United States)

    Hendrick; Jheng, Jyun-Teng; Tsai, Chen-Chai; Liou, Jia-Wei; Wang, Zhi-Hao; Jong, Gwo-Jia

    2017-07-01

    Intelligent appliances wisdom involves security, home care, convenient and energy saving, but the home automation system is still one of the core unit, and also using micro-processing electronics technology to centralized and control the home electrical products and systems, such as: lighting, television, fan, air conditioning, stereo, it composed of front-controller systems and back-controller panels, user using front-controller to control command, and then through the back-controller to powered the device.

  16. Weld analysis and control system

    Science.gov (United States)

    Kennedy, Larry Z. (Inventor); Rodgers, Michael H. (Inventor); Powell, Bradley W. (Inventor); Burroughs, Ivan A. (Inventor); Goode, K. Wayne (Inventor)

    1994-01-01

    The invention is a Weld Analysis and Control System developed for active weld system control through real time weld data acquisition. Closed-loop control is based on analysis of weld system parameters and weld geometry. The system is adapted for use with automated welding apparatus having a weld controller which is capable of active electronic control of all aspects of a welding operation. Enhanced graphics and data displays are provided for post-weld analysis. The system provides parameter acquisition, including seam location which is acquired for active torch cross-seam positioning. Torch stand-off is also monitored for control. Weld bead and parent surface geometrical parameters are acquired as an indication of weld quality. These parameters include mismatch, peaking, undercut, underfill, crown height, weld width, puddle diameter, and other measurable information about the weld puddle regions, such as puddle symmetry, etc. These parameters provide a basis for active control as well as post-weld quality analysis and verification. Weld system parameters, such as voltage, current and wire feed rate, are also monitored and archived for correlation with quality parameters.

  17. Quality transitivity and traceability system of herbal medicine products based on quality markers.

    Science.gov (United States)

    Liu, Changxiao; Guo, De-An; Liu, Liang

    2018-05-15

    Due to a variety of factors to affect the herb quality, the existing quality management model is unable to evaluate the process control. The development of the concept of "quality marker" (Q-marker) lays basis for establishing an independent process quality control system for herbal products. To ensure the highest degree of safety, effectiveness and quality process control of herbal products, it is aimed to establish a quality transitivity and traceability system of quality and process control from raw materials to finished herbal products. Based on the key issues and challenges of quality assessment, the current status of quality and process controls from raw materials to herbal medicinal products listed in Pharmacopoeia were analyzed and the research models including discovery and identification of Q-markers, analysis and quality management of risk evaluation were designed. Authors introduced a few new technologies and methodologies, such as DNA barcoding, chromatographic technologies, fingerprint analysis, chemical markers, bio-responses, risk management and solution for quality process control. The quality and process control models for herbal medicinal products were proposed and the transitivity and traceability system from raw materials to the finished products was constructed to improve the herbal quality from the entire supply and production chain. The transitivity and traceability system has been established based on quality markers, especially on how to control the production process under Good Engineering Practices, as well as to implement the risk management for quality and process control in herbal medicine production. Copyright © 2018 Elsevier GmbH. All rights reserved.

  18. Personal exposure control system

    International Nuclear Information System (INIS)

    Tanabe, Ken-ichi; Akashi, Michio

    1994-01-01

    Nuclear power stations are under strict radiation control. Exposure control for nuclear workers is the most important operation, and so carefully thought out measures are taken. This paper introduces Fuji Electric's personal exposure control system that meets strict exposure control and rationalizes control operations. The system has a merit that it can provide required information in an optimum form using the interconnection of a super minicomputer and exposure control facilities and realizes sophisticated exposure control operations. (author)

  19. Analysis of quality control tests done by the Canadian power utilities on their external dosimetry systems (June 1988 to May 1993)

    International Nuclear Information System (INIS)

    Butt, K.A.; Poirier, G.S.

    1995-09-01

    The Canadian nuclear power utilities, Hydro-Quebec, New Brunswick Electric Power Commission and Ontario Hydro, use thermoluminescent dosimetry systems to perform their own external beta/gamma dosimetry. In order to help ensure that these systems perform satisfactorily, they are subjected to routine quality control testing by their parent organizations. The test results for the period of June 1988 to May 1993 have been analyzed, at the Atomic Energy Control Board (AECB), using the pass criterion which was originally agreed upon the organizations involved and which is described in section 2.3 of this document. The present analysis offers an indication of the performance of the different sites which operate such a service. Comparisons are made each site's performance during the period June 1985 to May 1988 which has been summarized previously (INFO--0301). Finally, recommendations are made in the hope that they will help the organizations in refining their dosimetry. (author) 1 ref., 7 tabs

  20. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  1. Descriptive study of the quality control in mammography

    International Nuclear Information System (INIS)

    Gaona, E.; Perdigon C, G.M.; Casian C, G.A.; Azorin N, J.; Diaz G, J.A.I.; Arreola, M.

    2005-01-01

    The goal of mammography is to provide contrast between a lesion that is possible residing within the breast and normal surrounding tissue. Quality control is essential for maintaining the contrast imaging performance of a mammography system and incorporate tests that are relevant in that they are predictive of future degradation of contrast imaging performance. These tests will also be done at frequency that is high enough to intercept most drifts in quality imaging or performance before they become diagnostically significant. The quality control study has as objective to describe the results of the assessment of quality imaging elements (film optical density, contrast (density difference), uniformity, resolution and noise) of 62 mammography departments without quality control program and comparison these results with a mammography reference department with a quality control program. When comparing the results they allow seeing the clinical utility of to have a quality control program to reduce the errors of mammography interpretation. (Author)

  2. Evaluation of emission control strategies to reduce ozone pollution in the Paso del Norte region using a photochemical air quality modeling system

    Science.gov (United States)

    Valenzuela, Victor Hugo

    Air pollution emissions control strategies to reduce ozone precursor pollutants are analyzed by applying a photochemical modeling system. Simulations of air quality conditions during an ozone episode which occurred in June, 2006 are undertaken by increasing or reducing area source emissions in Ciudad Juarez, Chihuahua, Mexico. Two air pollutants are primary drivers in the formation of tropospheric ozone. Oxides of nitrogen (NOx) and volatile organic compounds (VOC) undergo multiple chemical reactions under favorable meteorological conditions to form ozone, which is a secondary pollutant that irritates respiratory systems in sensitive individuals especially the elderly and young children. The U.S. Environmental Protection Agency established National Ambient Air Quality Standards (NAAQS) to limit ambient air pollutants such as ozone by establishing an 8-hour average concentration of 0.075 ppm as the threshold at which a violation of the standard occurs. Ozone forms primarily due reactions in the troposphere of NOx and VOC emissions generated primarily by anthropogenic sources in urban regions. Data from emissions inventories indicate area sources account for ˜15 of NOx and ˜45% of regional VOC emissions. Area sources include gasoline stations, automotive paint bodyshops and nonroad mobile sources. Multiplicity of air pollution emissions sources provides an opportunity to investigate and potentially implement air quality improvement strategies to reduce emissions which contribute to elevated ozone concentrations. A baseline modeling scenario was established using the CAMx photochemical air quality model from which a series of sensitivity analyses for evaluating air quality control strategies were conducted. Modifications to area source emissions were made by varying NOx and / or VOC emissions in the areas of particular interest. Model performance was assessed for each sensitivity analysis. Normalized bias (NB) and normalized error (NE) were used to identify

  3. Some observations about quality control tests of Spect

    International Nuclear Information System (INIS)

    Robilotta, C.C.; Rebelo, M.F.S.; Oliveira, M.A.

    1987-01-01

    Some observations about quality control tests done in the tomographic system of Heart Institute are described. Among the tests, the traditional test of quality control with scintillation camera and the specific test for tomography systems are induced. The traditional tests are essential, but not sufficient for evaluating the Spect equipment and the specific tests have been effectuated in controlled conditions. (C.G.C.) [pt

  4. Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City

    International Nuclear Information System (INIS)

    Dong, Kyung Rae; Lee, Seun Joo; Lee, Kyu Su; Kweon, Dae Cheol; Goo, Eun Hoe; Jung, Jae Eun; Lee, Kyu Su

    2010-01-01

    With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within 1.5 . deg. . Of all fifty hospitals 30.0% were beyond 3 . deg. . The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible

  5. The remote control system

    International Nuclear Information System (INIS)

    Jansweijer, P.P.M.

    1988-01-01

    The remote-control system is applied in order to control various signals in the car of the spectrometer at distance. The construction (hardware and software) as well as the operation of the system is described. (author). 20 figs

  6. Control and automation systems

    International Nuclear Information System (INIS)

    Schmidt, R.; Zillich, H.

    1986-01-01

    A survey is given of the development of control and automation systems for energy uses. General remarks about control and automation schemes are followed by a description of modern process control systems along with process control processes as such. After discussing the particular process control requirements of nuclear power plants the paper deals with the reliability and availability of process control systems and refers to computerized simulation processes. The subsequent paragraphs are dedicated to descriptions of the operating floor, ergonomic conditions, existing systems, flue gas desulfurization systems, the electromagnetic influences on digital circuits as well as of light wave uses. (HAG) [de

  7. Application of improved quality control technology to pressure vessels

    International Nuclear Information System (INIS)

    Kriedt, F.

    1985-01-01

    Within the last decade, ASME Boiler and Pressure Vessel Code Section VIII-1 instituted requirements for a formal written quality control system. The results, good and bad, of this requirement are discussed. The effects are far reaching from a national economic standpoint. Quality control technology has improved. These improvements are discussed and compared to existing requirements of the CODE. Recommended improvements are suggested

  8. ISABELLE control system

    International Nuclear Information System (INIS)

    Humphrey, J.W.; Frankel, R.S.; Niederer, J.A.

    1980-01-01

    Design principles for the Brookhaven ISABELLE control intersecting storage ring accelerator are described. Principal features include a locally networked console and control computer complex, a system wide process data highway, and intelligent local device controllers. Progress to date is summarized

  9. The results of a quality-control programme in mammography

    International Nuclear Information System (INIS)

    Ramsdale, M.L.; Hiles, P.A.

    1989-01-01

    With the introduction of a breast screening programme in the UK, quality assurance in mammography is of paramount importance in assuring optimum imaging performance with low dose. Quality control checks are an essential part of the quality-assurance system. A quality-control programme at a breast screening clinic is described. Daily checks include film sensitometry for X-ray processor control and radiography of a lucite phantom to monitor the consistency of the X-ray machine automatic exposure control. Weekly checks include additional measurements on the performance of the automatic exposure control for different breast thickness and an overall assessment of image quality using a prototype mammography test phantom. The test phantom measures low-contrast sensitivity, high-contrast resolution and small-detail visibility. The results of the quality-control programme are presented with particular attention paid to tolerances and limiting values. (author)

  10. Quality control with R an ISO standards approach

    CERN Document Server

    Cano, Emilio L; Prieto Corcoba, Mariano

    2015-01-01

    Presenting a practitioner's guide to capabilities and best practices of quality control systems using the R programming language, this volume emphasizes accessibility and ease-of-use through detailed explanations of R code as well as standard statistical methodologies. In the interest of reaching the widest possible audience of quality-control professionals and statisticians, examples throughout are structured to simplify complex equations and data structures, and to demonstrate their applications to quality control processes, such as ISO standards. The volume balances its treatment of key aspects of quality control, statistics, and programming in R, making the text accessible to beginners and expert quality control professionals alike. Several appendices serve as useful references for ISO standards and common tasks performed while applying quality control with R.

  11. Image processing system performance prediction and product quality evaluation

    Science.gov (United States)

    Stein, E. K.; Hammill, H. B. (Principal Investigator)

    1976-01-01

    The author has identified the following significant results. A new technique for image processing system performance prediction and product quality evaluation was developed. It was entirely objective, quantitative, and general, and should prove useful in system design and quality control. The technique and its application to determination of quality control procedures for the Earth Resources Technology Satellite NASA Data Processing Facility are described.

  12. Amoeba-related health risk in drinking water systems: could monitoring of amoebae be a complementary approach to current quality control strategies?

    Science.gov (United States)

    Codony, Francesc; Pérez, Leonardo Martín; Adrados, Bárbara; Agustí, Gemma; Fittipaldi, Mariana; Morató, Jordi

    2012-01-01

    Culture-based methods for fecal indicator microorganisms are the standard protocol to assess potential health risk from drinking water systems. However, these traditional fecal indicators are inappropriate surrogates for disinfection-resistant fecal pathogens and the indigenous pathogens that grow in drinking water systems. There is now a range of molecular-based methods, such as quantitative PCR, which allow detection of a variety of pathogens and alternative indicators. Hence, in addition to targeting total Escherichia coli (i.e., dead and alive) for the detection of fecal pollution, various amoebae may be suitable to indicate the potential presence of pathogenic amoeba-resisting microorganisms, such as Legionellae. Therefore, monitoring amoeba levels by quantitative PCR could be a useful tool for directly and indirectly evaluating health risk and could also be a complementary approach to current microbial quality control strategies for drinking water systems.

  13. Quality Management of CERN Vacuum Controls

    CERN Document Server

    Antoniotti, F; Fortescue-Beck, E; Gama, J; Gomes, P; Le Roux, P; Pereira, H; Pigny, G

    2014-01-01

    The vacuum controls Section (TE-VSC-ICM) is in charge of the monitoring, maintenance and consolidation of the control systems of all accelerators and detectors in CERN; this represents 6 000 instruments distributed along 128 km of vacuum chambers, often of heterogeneous architectures and of diverse technical generations. In order to improve the efficiency of the services provided by ICM, to vacuum experts and to accelerator operators, a Quality Management Plan is being put into place. The first step was the standardization of the naming convention across different accelerators. The traceability of problems, requests, repairs, and other actions, has also been put into place (VTL). This was combined with the effort to identify each individual device by a coded label, and register it in a central database (MTF). Occurring in parallel, was the gathering of old documents and the centralization of information concerning architectures, procedures, equipment and settings (EDMS). To describe the topology of control c...

  14. Shipping/Receiving and Quality Control

    Data.gov (United States)

    Federal Laboratory Consortium — Shipping receiving, quality control, large and precise inspection and CMM machines. Coordinate Measuring Machines, including "scanning" probes, optical comparators,...

  15. Quality control of static irradiation processing products

    International Nuclear Information System (INIS)

    Bao Jianzhong; Chen Xiulan; Cao Hong; Zhai Jianqing

    2002-01-01

    Based on the irradiation processing practice of the nuclear technique application laboratory of Yangzhou Institute of Agricultural Science, the quality control of irradiation processing products is discussed

  16. How to set up and manage quality control and quality assurance

    NARCIS (Netherlands)

    Visschedijk, M.; Hendriks, R.; Nuyts, K.

    2005-01-01

    This document provides a general introduction to clarify the differences between quality control (QC) and quality assurance (QA). In addition it serves as a starting point for implementing a quality system approach within an organization. The paper offers practical guidance to the implementation of

  17. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  18. Reactor control system. PWR

    International Nuclear Information System (INIS)

    2009-01-01

    At present, 23 units of PWR type reactors have been operated in Japan since the start of Mihama Unit 1 operation in 1970 and various improvements have been made to upgrade operability of power stations as well as reliability and safety of power plants. As the share of nuclear power increases, further improvements of operating performance such as load following capability will be requested for power stations with more reliable and safer operation. This article outlined the reactor control system of PWR type reactors and described the control performance of power plants realized with those systems. The PWR control system is characterized that the turbine power is automatic or manually controlled with request of the electric power system and then the nuclear power is followingly controlled with the change of core reactivity. The system mainly consists of reactor automatic control system (control rod control system), pressurizer pressure control system, pressurizer water level control system, steam generator water level control system and turbine bypass control system. (T. Tanaka)

  19. Basic quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Wikstrom, Erik

    2016-01-01

    Along the route toward regular performance of Quality Control in the Diagnostic Imaging sector there are a number of balances to negotiate: Patient/Staff safety considerations vs Regulatory compliance vs Performance of modern equipment vs Clinic's Productivity. At first glance these ambitions may seem in conflict. The tests performed to meet regulatory requirements may or may not bear any semblance to real clinical measurement scenarios. And the process of collecting the data from the quality assurance tests may induce a system down- time that adversely affects the clinic's overall productivity. Furthermore, the time it takes to complete the analysis of the test data and provide the report required to take the facility back into operation is time wasted for patients waiting for a diagnostic imaging exam

  20. The study on quality control of bedside CR examination

    International Nuclear Information System (INIS)

    Yang Xufeng; Luo Xiaomei; Xu Qiaolan; Wu Tengfang; Wen Xingwei

    2007-01-01

    Objective: To study the quality controll of bedside CR examination and improves the imaging quality. Methods: X-ray examination with CR system were performed on 3,300 patients. All CR cassettes were encoded. The imaging plate and cassettes were cleaned regularly. Results: With and without quality control, the percentage of first-rate film was 58.2% and 51%, the second-rate film was 40% and 45.5%, the third-rate film was 1.3% and 2%, respectively. Corxespondingly, the ratio of re-examination decreased from 1.5% to 0.5% after quality control, and imaging quality was stable. Conclusion: The quality control of bedside CR examination can improve the image quality as well as lighten the labor of radiographers. (authors)

  1. Quality Control in Production Processes

    Directory of Open Access Journals (Sweden)

    Prístavka Miroslav

    2016-09-01

    Full Text Available The tools for quality management are used for quality improvement throughout the whole Europe and developed countries. Simple statistics are considered one of the most basic methods. The goal was to apply the simple statistical methods to practice and to solve problems by using them. Selected methods are used for processing the list of internal discrepancies within the organization, and for identification of the root cause of the problem and its appropriate solution. Seven basic quality tools are simple graphical tools, but very effective in solving problems related to quality. They are called essential because they are suitable for people with at least basic knowledge in statistics; therefore, they can be used to solve the vast majority of problems.

  2. Implementing self sustained quality control procedures in a clinical laboratory.

    Science.gov (United States)

    Khatri, Roshan; K C, Sanjay; Shrestha, Prabodh; Sinha, J N

    2013-01-01

    Quality control is an essential component in every clinical laboratory which maintains the excellence of laboratory standards, supplementing to proper disease diagnosis, patient care and resulting in overall strengthening of health care system. Numerous quality control schemes are available, with combinations of procedures, most of which are tedious, time consuming and can be "too technical" whereas commercially available quality control materials can be expensive especially for laboratories in developing nations like Nepal. Here, we present a procedure performed at our centre with self prepared control serum and use of simple statistical tools for quality assurance. The pooled serum was prepared as per guidelines for preparation of stabilized liquid quality control serum from human sera. Internal Quality Assessment was performed on this sample, on a daily basis which included measurement of 12 routine biochemical parameters. The results were plotted on Levey-Jennings charts and analysed with quality control rules, for a period of one month. The mean levels of biochemical analytes in self prepared control serum were within normal physiological range. This serum was evaluated every day along with patients' samples. The results obtained were plotted on control charts and analysed using common quality control rules to identify possible systematic and random errors. Immediate mitigation measures were taken and the dispatch of erroneous reports was avoided. In this study we try to highlight on a simple internal quality control procedure which can be performed by laboratories, with minimum technology, expenditure, and expertise and improve reliability and validity of the test reports.

  3. Activity and participation, quality of life and user satisfaction outcomes of environmental control systems and smart home technology

    DEFF Research Database (Denmark)

    Brandt, Ase; Samuelsson, Kersti A M; Töytäri, Outi

    2011-01-01

    , and two journals were searched without language or study design restrictions covering the period January 1993 - June 2009. Reviewers selected studies, extracted data, and assessed the methodological quality independently. RESULT: Of 1739 studies identified, five effect studies and six descriptive studies...

  4. 21 CFR 111.105 - What must quality control personnel do?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What must quality control personnel do? 111.105..., LABELING, OR HOLDING OPERATIONS FOR DIETARY SUPPLEMENTS Production and Process Control System: Requirements for Quality Control § 111.105 What must quality control personnel do? Quality control personnel must...

  5. 21 CFR 111.127 - What quality control operations are required for packaging and labeling operations?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.127 What quality control operations are required for packaging and labeling operations? Quality control operations for packaging and...

  6. 21 CFR 111.130 - What quality control operations are required for returned dietary supplements?

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 2 2010-04-01 2010-04-01 false What quality control operations are required for... and Process Control System: Requirements for Quality Control § 111.130 What quality control operations are required for returned dietary supplements? Quality control operations for returned dietary...

  7. Quality control education in the community college

    Science.gov (United States)

    Greene, J. Griffen; Wilson, Steve

    1966-01-01

    This paper describes the Quality Control Program at Daytona Beach Junior College, including course descriptions. The program in quality control required communication between the college and the American Society for Quality Control (ASQC). The college has machinery established for certification of the learning process, and the society has the source of teachers who are competent in the technical field and who are the employers of the educational products. The associate degree for quality control does not have a fixed program, which can serve all needs, any more than all engineering degrees have identical programs. The main ideas which would be common to all quality control programs are the concept of economic control of a repetitive process and the concept of developing individual potentialities into individuals who are needed and productive.

  8. QUEST: Quality of Expert Systems

    NARCIS (Netherlands)

    Perre, M.

    1991-01-01

    TNO Physics and Electronics laboratory, in collaboration with the University of Limburg and the Research Institute for Knowledge Systems, worked on a technology project named 'QUEST: Quality of Expert Systems' [FEL90]. QUEST was carried out under commision of the Dutch Ministry of Defence. A strong

  9. Internal control reporting and accounting quality : Insight "comply-or-explain" internal control regime

    OpenAIRE

    Cao Thi Thanh, Huyen; Cheung, Tina

    2010-01-01

    Nowadays, there exist two reporting regimes, rules-based and principle-based (comply-or-explain). In the rules-based environment, researchers have studied the relationship between internal control quality and accounting quality. Prior studies have suggested that reports on internal control are an effective way for investors to evaluate the quality of the firm‟s internal control. By having a sound system of internal control, it creates reliance upon the firm‟s financial reporting. Therefore, t...

  10. Measurement system as a subsystem of the quality management system

    Directory of Open Access Journals (Sweden)

    Ľubica Floreková

    2006-12-01

    Full Text Available Each measurement system and a control principle must be based on certain facts about the system behaviour (what, operation (how and structure (why. Each system is distributed into subsystems that provide an input for the next subsystem. For each system, start is important the begin, that means system characteristics, collecting of data, its hierarchy and the processes distribution.A measurement system (based on the chapter 8 of the standard ISO 9001:2000 Quality management system, requirements defines the measurement, analysis and improvement for each organization in order to present the products conformity, the quality management system conformity guarantee and for the continuously permanent improvement of effectivity, efficiency and economy of quality management system.

  11. Power Quality Improvement Of Grid Integrated Type I Wind Turbine Generation System Operating as DSTATCOM by d-q Control Method

    Directory of Open Access Journals (Sweden)

    S V S Phani Kumar.Ch

    2016-06-01

    Full Text Available In recent years with the excessive consumption of electrical energy, the incongruity between generation and demand, the irrational structure of World’s energy as well as the environmental pollution have become progressively more evident. It has become crucial for ecological development to reduce the consumption of conventional energy and to enhance the development and utilization of renewable energy. Wind energy and Solar are unlimited supply of renewable energy and it has no pollution. But this concept suffer from the power quality issues from grid and generator side, this paper presents a control strategy for achieving maximum benefits from these grid-interfacing inverter when installed in 3-phase 4-wire distribution systems. The inverter can be controlled to perform as a multi-function device by incorporating active power filter functionality. The inverter can thus be utilized as: 1 power converter to inject power generated from RES to the grid and 2 shunt APF (Active Power Filter to compensate current unbalance, load current harmonics, load reactive power demand and load neutral current. All of these functions may be accomplished either individually or simultaneously. With such a control, the combination of grid-interfacing inverter and the 3-phase 4-wire linear/non-linear unbalanced load at point of common coupling appears as balanced linear load to the grid. The Paper propose design of 500kW Type I Wind Generation System 250kW each with Four Leg Inverter Controlled by d-q technique operated as DSTATCOM connected to 415V 4 wire Grid and also the results are compared with conventional Unit Vector Control. The proposed d-q method reduces the %THD of system to 1.97% from 24.12% where Unit Vector Control is of 3.94% which was on higher side , this is simulated in MATLAB/SIMULINK.

  12. Integrated control systems

    International Nuclear Information System (INIS)

    Smith, D.J.

    1991-01-01

    This paper reports that instrument manufacturers must develop standard network interfaces to pull together interrelated systems such as automatic start-up, optimization programs, and online diagnostic systems. In the past individual control system manufacturers have developed their own data highways with proprietary hardware and software designs. In the future, electric utilities will require that future systems, irrespective of manufacturer, should be able to communicate with each other. Until now the manufactures of control systems have not agreed on the standard high-speed data highway system. Currently, the Electric Power Research Institute (EPRI), in conjunction with several electric utilities and equipment manufactures, is working on developing a standard protocol for communicating between various manufacturers' control systems. According to N. Michael of Sargent and Lundy, future control room designs will require that more of the control and display functions be accessible from the control room through CRTs. There will be less emphasis on traditional hard-wired control panels

  13. Related regulation of quality control of industrial products

    International Nuclear Information System (INIS)

    1983-04-01

    This book introduce related regulation of quality control of industrial products, which includes regulations of industrial products quality control, enforcement ordinance of industrial products quality control, enforcement regulation of quality control of industrial products, designated items with industrial production quality indication, industrial production quality test, and industrial production quality test organization and management tips of factory quality by grade.

  14. ISO 9001 quality management systems

    CERN Document Server

    Natarajan, Dhanasekharan

    2017-01-01

    This book explains the requirements of ISO 9001 for establishing quality management system (QMS) for an organization. The requirements are illustrated with examples from industries for understanding the requirements and preparing the documents of QMS with high clarity. Methods of integrating ISO 9001 requirements with enterprise resource planning (ERP) software are presented. The software integrated approach enables process owners to focus on their core tasks of achieving the planned outputs of processes and the software generates quality records automatically.

  15. A national control system

    International Nuclear Information System (INIS)

    Larsson, A.

    1975-01-01

    An effective control of nuclear fissionable material is dependent on three different kinds of control, the industry - laboratory management, a national control system and an international safeguards system. The national systems of control differ greatly between various industrialized countries. Two principal reasons for fact can be mentioned. The type and the amounts for nuclear material may be different depending upon the stage of development of the nuclear industry in the country in question. Another reason may be that the country may wish to establish a very elaborate national system of control in order to minimize the IAEA control as much as possible. The two safeguards agreements between the Agency and Sweden on one hand and the Agency and Japan on the other hand can serve as examples for the understanding of the latitude of the IAEA safeguards system under NPT due to the influence of the national control system. If it thus is apparent that the national control system is strongly interrelated to the international safeguards system it is equally influenced by the control and accountancy systems which exist at the nuclear plants and development laboratories. A detailed study of national control systems and their relations to plant management control would fall outside the scope of this article. Some important features will however be examined. (author)

  16. Quality control of nuclear medicine instrumentation

    International Nuclear Information System (INIS)

    Mould, R.F.

    1983-09-01

    The proceedings of a conference held by the Hospital Physicists' Association in London 1983 on the quality control of nuclear medicine instrumentation are presented. Section I deals with the performance of the Anger gamma camera including assessment during manufacture, acceptance testing, routine testing and long-term assessment of results. Section II covers interfaces, computers, the quality control problems of emission tomography and the quality of software. Section III deals with radionuclide measurement and impurity assessment and Section IV the presentation of images and the control of image quality. (U.K.)

  17. Quality management system in ISTC 'Ukryttia'

    International Nuclear Information System (INIS)

    Ershova, N.N.; Klyuchnikov, A.A.; Lagutin, I.G.

    2003-01-01

    Some structural and certification aspects of ISTC 'Ukryttia' quality system are seen,and main principles of adaptation of existing quality system model to quality management system model in conformity with ISO 9001:2000 standard are shown

  18. Development of the quality control system of the readout electronics for the large size telescope of the Cherenkov Telescope Array observatory

    Science.gov (United States)

    Konno, Y.; Kubo, H.; Masuda, S.; Paoletti, R.; Poulios, S.; Rugliancich, A.; Saito, T.

    2016-07-01

    The Cherenkov Telescope Array (CTA) is the next generation VHE γ-ray observatory which will improve the currently available sensitivity by a factor of 10 in the range 100 GeV to 10 TeV. The array consists of different types of telescopes, called large size telescope (LST), medium size telescope (MST) and small size telescope (SST). A LST prototype is currently being built and will be installed at the Observatorio Roque de los Muchachos, island of La Palma, Canary islands, Spain. The readout system for the LST prototype has been designed and around 300 readout boards will be produced in the coming months. In this note we describe an automated quality control system able to measure basic performance parameters and quickly identify faulty boards.

  19. Analysis of quality control tests done by the Canadian power utilities on their external dosimetry systems (June 1985 to May 1988)

    International Nuclear Information System (INIS)

    Poirier, G.S.

    1989-04-01

    The Canadian nuclear power utilities, Hydro Quebec, New Brunswick Electric Power Commission and Ontario Hydro, use thermoluminescent dosimetry systems to perform their own external beta/gamma dosimetry. In order to help ensure that these systems perform satisfactorily, they are subjected to routine quality control testing by their parent organizations. The test results for the period of June 1985 to May 1988 have been analyzed, at the AECB, using the pass criterion which was originally agreed upon by the organizations involved. The present analysis offers a comparison of the performance of the different sites which operate such a service. Finally, recommendations are made in the hope that they will help the organizations in refining their dosimetry

  20. Developing methods of controlling quality costs

    OpenAIRE

    Gorbunova A. V.; Maximova O. N.; Ekova V. A.

    2017-01-01

    The article examines issues of managing quality costs, problems of applying economic methods of quality control, implementation of progressive methods of quality costs management in enterprises with the view of improving the efficiency of their evaluation and analysis. With the aim of increasing the effectiveness of the cost management mechanism, authors introduce controlling as a tool of deviation analysis from the standpoint of the process approach. A list of processes and corresponding eva...

  1. Intelligent control systems 1990

    International Nuclear Information System (INIS)

    Shoureshi, R.

    1991-01-01

    The field of artificial intelligence (Al) has generated many useful ideas and techniques that can be integrated into the design of control systems. It is believed and, for special cases, has been demonstrated, that integration of Al into control systems would provide the necessary tools for solving many of the complex problems that present control techniques and Al algorithms are unable to do, individually. However, this integration requires the development of basic understanding and new fundamentals to provide scientific bases for achievement of its potential. This book presents an overview of some of the latest research studies in the area of intelligent control systems. These papers present techniques for formulation of intelligent control, and development of the rule-based control systems. Papers present applications of control systems in nuclear power plants and HVAC systems

  2. Quality label 'Geothermal energy source' (quality-assurance system)

    International Nuclear Information System (INIS)

    Eugster, W. J.

    2005-01-01

    The design of borehole heat exchanger (BHE) plants is covered only marginally through the existing quality labels. And only for small and simple systems. Especially the middle and large sized BHE plants are excluded from the labels. And exactly those plants may be very difficult to treat and to handle. Two concepts of quality control are proposed. On one hand a quality label, which is based on an object sheet, that is both, a planning help and a quality proof. There is no duty for the heating/ventilation/air-conditioning (HVAC) engineers to acquire such a quality label. The label is based on a self quality declaration of the engineers. Therefore a controlling system is needed which induces costs to the labelled engineers. A market penetration of around 20% is predicted for the first three years. The second concept is based on a clear definition of the actual state of the art in designing a BHE plant in a formal standard by the Swiss Engineers and Architects Society (SIA). This concept is proposed for realisation. Nearly 90% of the Swiss BHE drilling market is penetrated by the labelled drilling companies which have agreed to demand from their HVAC engineers (planners) to apply the future SIA standard, either by their general drilling and delivery conditions or by a special agreement. This fact guarantees a fast spreading and application of such a new SIA standard. A collateral information offensive for the HVAC engineers working in the design of BHE plants needs to be stated in any way. This method is not only very cheap but also guarantees a fast and a broad market penetration which must have nearly the same grade as the quality label for drilling companies. But of course, the new standard has to be elaborated first, what should be possible within approximately one year. (author)

  3. Research Ship Oceanus Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Oceanus Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  4. Research Ship Melville Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Melville Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  5. Research Ship Healy Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Healy Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  6. Research Ship Knorr Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Knorr Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  7. NOAA Ship Delaware II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Delaware II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  8. Research Ship Atlantis Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Atlantis Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  9. NOAA Ship Pisces Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Pisces Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System (SAMOS)...

  10. NOAA Ship Fairweather Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Fairweather Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  11. NOAA Ship Hi'ialakai Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Hi'ialakai Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  12. NOAA Ship Ronald Brown Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ronald Brown Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  13. NOAA Ship Miller Freeman Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Miller Freeman Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  14. NOAA Ship Oscar Dyson Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oscar Dyson Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  15. Research Ship Kilo Moana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Kilo Moana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  16. NOAA Ship Nancy Foster Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Nancy Foster Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  17. NOAA Ship Gordon Gunter Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Gordon Gunter Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  18. NOAA Ship Rainier Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Rainier Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  19. Research Ship Tangaroa Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — Research Ship Tangaroa Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  20. NOAA Ship Ka'imimoana Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Ka'imimoana Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  1. NOAA Ship Oregon II Underway Meteorological Data, Quality Controlled

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — NOAA Ship Oregon II Underway Meteorological Data (delayed ~10 days for quality control) are from the Shipboard Automated Meteorological and Oceanographic System...

  2. Quality controls of radiopharmaceuticals used in nuclear medicine

    International Nuclear Information System (INIS)

    Gomez de Castiglia, S.I.; Fraga de Suarez, A.H.; Mitta, A.E.A.

    1981-01-01

    Chromatographic quality controls for Tc-99m; In-113m; I-131; Tl-201 and Ga-67 radiopharmaceuticals are described. Moreover, a chromatographic system which allows to separate different radiopharmaceuticals from In-113m is pointed out. (author) [es

  3. Fuel manufacture and quality control

    International Nuclear Information System (INIS)

    Roepenack, H.; Raab, K.

    1975-01-01

    The different steps in fuel and fuel element manufacturing from the conversion of UF 6 to UO 2 to the assembling of the whole fuel element are shortly described. Each of this fabrication steps must satisfy well-defined quality criteria which are checked in certain analyses or tests. (RB) [de

  4. Quality Control in Mammography: Image Quality and Patient Doses

    International Nuclear Information System (INIS)

    Ciraj Bjelac, O.; Arandjic, D.; Boris Loncar, B.; Kosutic, D.

    2008-01-01

    Mammography is method of choice for early detection of breast cancer. The purpose of this paper is preliminary evaluation the mammography practice in Serbia, in terms of both quality control indicators, i.e. image quality and patient doses. The survey demonstrated considerable variations in technical parameters that affect image quality and patients doses. Mean glandular doses ranged from 0.12 to 2.8 mGy, while reference optical density ranged from 1.2 to 2.8. Correlation between image contrast and mean glandular doses was demonstrated. Systematic implementation of quality control protocol should provide satisfactory performance of mammography units and maintain satisfactory image quality and keep patient doses as low as reasonably practicable. (author)

  5. A modular control system

    International Nuclear Information System (INIS)

    Cruz, B.; Drexler, J.; Olcese, G.; Santome, D.

    1990-01-01

    The main objective of the modular control system is to provide the requirements to most of the processes supervision and control applications within the industrial automatization area. The design is based on distribution, modulation and expansion concepts. (Author) [es

  6. Applied Control Systems Design

    CERN Document Server

    Mahmoud, Magdi S

    2012-01-01

    Applied Control System Design examines several methods for building up systems models based on real experimental data from typical industrial processes and incorporating system identification techniques. The text takes a comparative approach to the models derived in this way judging their suitability for use in different systems and under different operational circumstances. A broad spectrum of control methods including various forms of filtering, feedback and feedforward control is applied to the models and the guidelines derived from the closed-loop responses are then composed into a concrete self-tested recipe to serve as a check-list for industrial engineers or control designers. System identification and control design are given equal weight in model derivation and testing to reflect their equality of importance in the proper design and optimization of high-performance control systems. Readers’ assimilation of the material discussed is assisted by the provision of problems and examples. Most of these e...

  7. Quality system for Medical laboratories

    Directory of Open Access Journals (Sweden)

    Shiva Raj K.C.

    2015-03-01

    Full Text Available According to William Edwards Deming “Good quality does not necessarily mean high quality. Instead it means a predicable degree of uniformity and dependability at low cost with a quality suited to the market.” Whereas according to famous engineer and management consultant Joseph M. Juran quality is “fitness for purpose”. It should meet the customers’ expectations and requirements, should be cost effective.ISO began in 1926 as the International Federation of the National Standardizing Associations (ISA. The name, "ISO" was derived from the Greek word "isos" meaning "equal". (The relation to standards is that if two objects meet the same standard, they should be equal. This name eliminates any confusion that could result from the translation of "International Organization for Standardization" into different languages which would lead to different acronyms.In health sector, quality plays pivotal role, as it is directly related to patient’s care. Earlier time, health service was simple, quite safe but ineffective. Now health care system is an organizational system with more complex processes to deliver care. Medical laboratory service is an integral part in patient’s management system. So, for everyone involved in the treatment of the patient, the accuracy, reliability and safety of those services must be the primary concerns. Accreditation is a significant enabler of quality, thereby delivering confidence to healthcare providers, clinicians, the medical laboratories and the patients themselves.ISO announced meeting in Philadelphia to form a technical committee to develop a new standard for medical laboratory quality. It took 7 years for the creation of a new Quality standard for medical laboratories. It was named as “ISO 15189” and was first published in 2003. The ISO has released three versions of the standard. The first two were released in 2003 and 2007. In 2012, a revised and updated version of the standard, ISO 15189

  8. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  9. Financial Management: Implementation of the Data Quality Management Control Program for the Military Health System (D-2002-141)

    National Research Council Canada - National Science Library

    2002-01-01

    DoD health care managers should read this report. Military health care data is used for a variety of critical purposes, including managing patient care, determining the optimal health care system, and for financial management...

  10. Quality control in the radioactive waste management

    International Nuclear Information System (INIS)

    Rzyski, B.M.

    1989-01-01

    Radioactive waste management as in industrial activities must mantain in all steps a quality control programme. This control extended from materials acquisition, for waste treatment, to the package deposition is one of the most important activities because it aims to observe the waste acceptance criteria in repositories and allows to guarantee the security of the nuclear facilities. In this work basic knowledges about quality control in waste management and some examples of adopted procedures in other countries are given. (author) [pt

  11. The ILC control system

    International Nuclear Information System (INIS)

    Carwardine, J.; Saunders, C.; Arnold, N.; Lenkszus, F.; Rehlich, K.; Simrock, S.; Banerjee, b.; Chase, B.; Gottschalk, E.; Joireman, P.; Kasley, P.; Lackey, S.; McBride, P.; Pavlicek, V.; Patrick, J.; Votava, M.; Wolbers, S.; Furukawa, K.; Michizono, S.; Larson, R.S.; Downing, R.

    2007-01-01

    Since the last ICALEPCS, a small multi-region team has developed a reference design model for a control system for the International Linear Collider as part of the ILC Global Design Effort. The scale and performance parameters of the ILC accelerator require new thinking in regards to control system design. Technical challenges include the large number of accelerator systems to be controlled, the large scale of the accelerator facility, the high degree of automation needed during accelerator operations, and control system equipment requiring 'Five Nines' availability. The R and D path for high availability touches the control system hardware, software, and overall architecture, and extends beyond traditional interfaces into the technical systems. Software considerations for HA include fault detection through exhaustive out-of-band monitoring and automatic state migration to redundant systems, while the telecom industry's emerging ATCA standard - conceived, specified, and designed for High Availability - is being evaluated for suitability for ILC front-end electronics.

  12. Home care for life-supported persons: the French system of quality control, technology assessment, and cost containment.

    OpenAIRE

    Goldberg, A I

    1989-01-01

    Home care for persons who require the prolonged use of life-supportive medical technology is a reality in several nations. France has had more than a quarter of a century of experience with providing home care for patients with chronic respiratory insufficiency and with a system to evaluate the patients' outcomes. The French approach features decentralized regional organizations which offer grassroots involvement by the beneficiaries who participate directly in the system. Since June 1981, a ...

  13. Quality assurance system in nuclear engineering

    International Nuclear Information System (INIS)

    Adams, H.W.; Hoensch, V.

    1985-01-01

    Due to the close connection between the German Atomic Energy Law and the nuclear control regulations, quality systems in nuclear engineering have taken on a special form. Quality assurance systems as a stipulated organisation of structure and procedure to assure quality have implications for the organisation of the electric supply company at the planning, erection and commissioning stage and for the organisation of the nuclear power station facility. To supervise the application and effectiveness of the stipulated organisation of structure and procedure internally and externally among contractors, special organisation units have been set up at the plant suppliers, manufactures, electric supply companies and nuclear power station facilities, which in the electric supply field go by the name of Quality Assurance Supervision. (orig.) [de

  14. Power Quality Control and Design of Power Converter for Variable-Speed Wind Energy Conversion System with Permanent-Magnet Synchronous Generator

    Directory of Open Access Journals (Sweden)

    Yüksel Oğuz

    2013-01-01

    Full Text Available The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  15. Power quality control and design of power converter for variable-speed wind energy conversion system with permanent-magnet synchronous generator.

    Science.gov (United States)

    Oğuz, Yüksel; Güney, İrfan; Çalık, Hüseyin

    2013-01-01

    The control strategy and design of an AC/DC/AC IGBT-PMW power converter for PMSG-based variable-speed wind energy conversion systems (VSWECS) operation in grid/load-connected mode are presented. VSWECS consists of a PMSG connected to a AC-DC IGBT-based PWM rectifier and a DC/AC IGBT-based PWM inverter with LCL filter. In VSWECS, AC/DC/AC power converter is employed to convert the variable frequency variable speed generator output to the fixed frequency fixed voltage grid. The DC/AC power conversion has been managed out using adaptive neurofuzzy controlled inverter located at the output of controlled AC/DC IGBT-based PWM rectifier. In this study, the dynamic performance and power quality of the proposed power converter connected to the grid/load by output LCL filter is focused on. Dynamic modeling and control of the VSWECS with the proposed power converter is performed by using MATLAB/Simulink. Simulation results show that the output voltage, power, and frequency of VSWECS reach to desirable operation values in a very short time. In addition, when PMSG based VSWECS works continuously with the 4.5 kHz switching frequency, the THD rate of voltage in the load terminal is 0.00672%.

  16. Control systems engineering

    CERN Document Server

    Nise, Norman S

    1995-01-01

    This completely updated new edition shows how to use MATLAB to perform control-system calculations. Designed for the professional or engineering student who needs a quick and readable update on designing control systems, the text features a series of tightly focused examples that clearly illustrate each concept of designing control systems. Most chapters conclude with a detailed application from the two case studies that run throughout the book: an antenna asimuth control system and a submarine. The author also refers to many examples of design methods.

  17. Quality Assurance and Control in Laboratory using Neutron Activation Analysis

    International Nuclear Information System (INIS)

    Chung, Y. S.; Moon, J. H.; Sun, G. M.; Kim, S. H.; Baek, S. Y.; Lim, J. M.; Kim, H. R.

    2007-01-01

    In accordance with the increment of international trade associated with the worldwide globalization, the importance of quality assurance and control for the commodity produced from one's own country has been stressed. ISO (International Organization for Standards) defines quality control as 'the operational techniques and activities that are used to fulfill the requirements for quality'. Since 1996, the HANARO research reactor in the Korea Atomic Energy Research Institute has been operated thereafter initial critical operation on April 1995. Neutron activation analysis system and applied techniques which is one of a nuclear analytical technologies using reactor neutrons has been developed for user's supporting and the establishment of the quality system for a measurement and analysis, testing and inspection was implemented successfully. On the basis of the qualified NAA system, the test and measurement of more than 1500 samples which is requested from 30 organizations including industrial companies, universities and institutes carried out in NAA laboratory annually. Moreover, as the goal of mutual recognition agreement (MRA) which can be removed a technical barrier in international trade, the objectivity and the confidence of analytical quality in NAA laboratory became established through the installation of international accreditation system by implementing analytical quality system in accordance with international standards in 2001. The aim of the report was to summarize the technical management of introduction, methods and the results for a quality control and assurance which should be performed in NAA technique using the HANARO research reactor. The report will help building up effective quality control strategy in the future

  18. Analysis And Control System For Automated Welding

    Science.gov (United States)

    Powell, Bradley W.; Burroughs, Ivan A.; Kennedy, Larry Z.; Rodgers, Michael H.; Goode, K. Wayne

    1994-01-01

    Automated variable-polarity plasma arc (VPPA) welding apparatus operates under electronic supervision by welding analysis and control system. System performs all major monitoring and controlling functions. It acquires, analyzes, and displays weld-quality data in real time and adjusts process parameters accordingly. Also records pertinent data for use in post-weld analysis and documentation of quality. System includes optoelectronic sensors and data processors that provide feedback control of welding process.

  19. Development of a postal system for dosimetry quality control performed in photon beams produced by linear accelerators of clinical use

    International Nuclear Information System (INIS)

    Di Prinzio, R.

    1984-01-01

    In this work a different system is proposed which is able to verify the absorbed depth dose given at two different depths, the irradiation field homogeneity and its coincidence with the light field of the machine, the source to surface distance used and the beam nominal energy. These radiation field parameters are very important in the tumour treatment and they may help in the determination of the error sources of the absorbed depth dose. The system developed uses a water phantom, LiF thermoluminescent dosemeters and a radiographic film to evaluate such parameters. The postal system developed in this work has been tested in linear accelerators of 4 to 18 MV with good results. (author)

  20. Suggestion for improvement of PET quality control tests in Brazil

    International Nuclear Information System (INIS)

    Ferreira, Fernanda C.L.; Magalhaes, Cinthia M.S.; Souza, Divanizia N.

    2009-01-01

    Nowadays nuclear medicine has a considerable importance among the other medical specialties. This medical specialty utilizes high-tech equipment for imaging in the diagnosis, obtaining information on the clinical functionality of organs and systems of the human body through the use of radioisotopes . In view of the importance of guaranteeing the image quality in SPECT and PET systems, enabling patients not repeat exams due to lack of quality control of equipment used in nuclear medicine, this paper aims to present a possible suggestion to update the quality control tests needed for quality assurance of nuclear medicine services. They were considered the requirements of the National Commission of Nuclear Energy (CNEN) and the National Health Surveillance Agency (ANVISA) in Brazil. The minimum requirements to be defined for inclusion of quality control tests on PET in the standard CNEN are extremely important because they will guide the evaluation of PET systems, determining the quality control tests to be performed. And those tests for PET will be a regulatory requirement by the CNEN and ANVISA. As the National Health Surveillance Agency has already publication of RDC 38 with recommendations for services of nuclear medicine. This study will continue with evaluation of PET systems and presenting the tests of quality control with additional objects and simulators to ensure safety in PET systems have not standardized in nuclear medicine services in Brazil. (author)