WorldWideScience

Sample records for quality assurance requirements

  1. Quality assurance management policies and requirements

    International Nuclear Information System (INIS)

    1985-10-01

    The purpose of this document is to: set forth overall, integrated quality assurance management policies and requirements for the entire Civilian Radioactive Waste Management Program; define management responsibilities for assuring quality; and provide a general framework for the development of more detailed quality assurance management policies and requirements by program, project, and contractor organizations

  2. Grading of quality assurance requirements

    International Nuclear Information System (INIS)

    1991-01-01

    The present Manual provides guidance and illustrative examples for applying a method by which graded quality assurance requirements may be determined and adapted to the items and services of a nuclear power plant in conformance with the requirements of the IAEA Nuclear Safety Standards (NUSS) Code and Safety Guides on quality assurance. The Manual replaces the previous publication IAEA-TECDOC-303 on the same subject. Various methods of grading quality assurance are available in a number of Member States. During the development of the present Manual it was not considered practical to attempt to resolve the differences between those methods and it was preferred to identify and benefit from the good practices available in all the methods. The method presented in this Manual deals with the aspects of management, documentation, control, verification and administration which affect quality. 1 fig., 4 tabs

  3. Quality Assurance Requirements and Description

    International Nuclear Information System (INIS)

    Ram Murthy

    2002-01-01

    The Quality Assurance Requirements and Description (QARD) is the principal Quality Assurance (QA) document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the QA program [INTRODUCTION :1p2s (NOT A REQUIREMENT)]. The QARD contains regulatory requirements and program commitments necessary for the development of an effective QA program [INTRODUCTION :1p3s (NOT A REQUIREMENT)]. Implementing documents must be based on, and be consistent with the QARD. The QARD applies to the following: (1) Acceptance of spent nuclear fuel and high-level waste. (2) Transport of spent nuclear fuel and high-level waste. (3) Storage of spent nuclear fuel through receipt of storage cask certification or a facility operating license. (4) Monitored Geologic Repository, including the site characterization activities [Exploratory Studies Facility (ESF) and surface based testing], through receipt of an operating license. (5) High-level waste form development through qualification, production, and acceptance. (6) Characterization of DOE spent nuclear fuel, and conditioning through acceptance of DOE spent nuclear fuel. Section 2.0, Quality Assurance Program, defines in greater detail criteria for determining work subject to the QARD

  4. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  5. Quality Assurance Source Requirements Traceability Database

    International Nuclear Information System (INIS)

    MURTHY, R.; NAYDENOVA, A.; DEKLEVER, R.; BOONE, A.

    2006-01-01

    At the Yucca Mountain Project the Project Requirements Processing System assists in the management of relationships between regulatory and national/industry standards source criteria, and Quality Assurance Requirements and Description document (DOE/R W-0333P) requirements to create compliance matrices representing respective relationships. The matrices are submitted to the U.S. Nuclear Regulatory Commission to assist in the commission's review, interpretation, and concurrence with the Yucca Mountain Project QA program document. The tool is highly customized to meet the needs of the Office of Civilian Radioactive Waste Management Office of Quality Assurance

  6. Manpower requirements for quality assurance during operation

    International Nuclear Information System (INIS)

    Pratt, J.M.; Sollenberger, L.G.

    1982-01-01

    As a result of the Three Mile Island accident and the findings presented in various investigatory reports, some fundamental changes are taking place in the role and scope of quality assurance. Recent changes to United States national codes, guides and standards are analysed in order to identify the principles involved. This analysis shows that the scope of the programme is being extended beyond the equipment designated 'nuclear safety related' and greater emphasis is being placed upon the independent verification of the satisfactory performance of activities affecting safety. Such fundamental changes could lead to a significant increase in the number of quality assurance personnel required to support an operating nuclear power plant. The evolving quality assurance organization at Three Mile Island is used to illustrate how these fundamental changes could affect the quality assurance organization and manpower requirements. (author)

  7. Development of quality assurance requirements - an international comparison

    Energy Technology Data Exchange (ETDEWEB)

    Link, M [Siemens AG, Bereich Energieerzeugung (KWU), Erlangen (Germany); Mertz, W [Siemens AG, Bereich Energieerzeugung (KWU), Offenbach am Main (Germany)

    1993-12-01

    Total quality management strategy and the worldwide introduction of the DIN/ISO 9000 (EN 29 000) series of standards have given new impetus to traditional quality assurance. The most important change must surely be seen in the holistic approach of total quality management and its strict orientation towards customer requirements and satisfaction. International codes and standards for the nuclear industry will also have to be brought into line as part of the process of harmonizing quality assurance system standards. One possible approach is simply to specify a supplementary 'delta' of nuclear-specific requirements to be appended to the broad range of conventional requirements. It is a particular feature of quality-assured procedures in Germany that product and/or component related quality requirements and quality verifications are defined in the specifications of the architect engineer so that full implementation of the requirements from the design phase through to the manufacturing phase is assured. Looking at the development of the European Pressurized Water Reactor (EPR) and the elaboration of 'Common Rules', it is to be anticipated that a major step will be made toward international harmonization of safety criteria. (orig.)

  8. Development of quality assurance requirements - an international comparison

    International Nuclear Information System (INIS)

    Link, M.; Mertz, W.

    1993-01-01

    Total quality management strategy and the worldwide introduction of the DIN/ISO 9000 (EN 29 000) series of standards have given new impetus to traditional quality assurance. The most important change must surely be seen in the holistic approach of total quality management and its strict orientation towards customer requirements and satisfaction. International codes and standards for the nuclear industry will also have to be brought into line as part of the process of harmonizing quality assurance system standards. One possible approach is simply to specify a supplementary 'delta' of nuclear-specific requirements to be appended to the broad range of conventional requirements. It is a particular feature of quality-assured procedures in Germany that product and/or component related quality requirements and quality verifications are defined in the specifications of the architect engineer so that full implementation of the requirements from the design phase through to the manufacturing phase is assured. Looking at the development of the European Pressurized Water Reactor (EPR) and the elaboration of 'Common Rules', it is to be anticipated that a major step will be made toward international harmonization of safety criteria. (orig.) [de

  9. Quality assurance requirements in various codes and standards

    International Nuclear Information System (INIS)

    Shaaban, H.I.; EL-Sayed, A.; Aly, A.E.

    1987-01-01

    The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants

  10. Mixed Waste Integrated Program Quality Assurance requirements plan

    International Nuclear Information System (INIS)

    1994-01-01

    Mixed Waste Integrated Program (MWIP) is sponsored by the US Department of Energy (DOE), Office of Technology Development, Waste Management Division. The strategic objectives of MWIP are defined in the Mixed Waste Integrated Program Strategic Plan, and expanded upon in the MWIP Program Management Plan. This MWIP Quality Assurance Requirement Plan (QARP) applies to mixed waste treatment technologies involving both hazardous and radioactive constituents. As a DOE organization, MWIP is required to develop, implement, and maintain a written Quality Assurance Program in accordance with DOE Order 4700.1 Project Management System, DOE Order 5700.6C, Quality Assurance, DOE Order 5820.2A Radioactive Waste Management, ASME NQA-1 Quality Assurance Program Requirements for Nuclear Facilities and ANSI/ASQC E4-19xx Specifications and Guidelines for Quality Systems for Environmental Data Collection and Environmental Technology Programs. The purpose of the MWIP QA program is to establish controls which address the requirements in 5700.6C, with the intent to minimize risks and potential environmental impacts; and to maximize environmental protection, health, safety, reliability, and performance in all program activities. QA program controls are established to assure that each participating organization conducts its activities in a manner consistent with risks posed by those activities

  11. Mixed Waste Integrated Program Quality Assurance requirements plan

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-15

    Mixed Waste Integrated Program (MWIP) is sponsored by the US Department of Energy (DOE), Office of Technology Development, Waste Management Division. The strategic objectives of MWIP are defined in the Mixed Waste Integrated Program Strategic Plan, and expanded upon in the MWIP Program Management Plan. This MWIP Quality Assurance Requirement Plan (QARP) applies to mixed waste treatment technologies involving both hazardous and radioactive constituents. As a DOE organization, MWIP is required to develop, implement, and maintain a written Quality Assurance Program in accordance with DOE Order 4700.1 Project Management System, DOE Order 5700.6C, Quality Assurance, DOE Order 5820.2A Radioactive Waste Management, ASME NQA-1 Quality Assurance Program Requirements for Nuclear Facilities and ANSI/ASQC E4-19xx Specifications and Guidelines for Quality Systems for Environmental Data Collection and Environmental Technology Programs. The purpose of the MWIP QA program is to establish controls which address the requirements in 5700.6C, with the intent to minimize risks and potential environmental impacts; and to maximize environmental protection, health, safety, reliability, and performance in all program activities. QA program controls are established to assure that each participating organization conducts its activities in a manner consistent with risks posed by those activities.

  12. Environmental Restoration Remedial Action quality assurance requirements document

    International Nuclear Information System (INIS)

    1991-01-01

    This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting quality, using a graded approach based on the importance of the item, service, or activity to the program objectives. The Quality Assurance Program that will be established using this document as the basis, together with other program and technical documents, form an integrated management control system for conducting the Environmental Restoration Remedial Action program activities in a manner that provides safety and protects the environment and public health

  13. National waste terminal storage program. Supplementary quality-assurance requirements

    International Nuclear Information System (INIS)

    Garland, D.L.

    1980-01-01

    The basic Quality Assurance Program Requirements standard for the National Waste Terminal Storage Program has been developed primarily for nuclear reactors and other fairly well established nuclear facilities. In the case of waste isolation, however, there are many ongoing investigations for which quality assurance practices and requirements have not been well defined. This paper points out these problems which require supplementary requirements. Briefly these are: (1) the language barrier, that is geologists and scientists are not familiar with quality assurance (QA) terminology; (2) earth sciences deal with materials that cannot be characterized as easily as metals or other materials that are reasonably homogeneous; (3) development and control of mathematical models and associated computer programs; (4) research and development

  14. The quality assurance liaison: Combined technical and quality assurance support

    International Nuclear Information System (INIS)

    Bolivar, S.L.; Day, J.L.

    1993-01-01

    This paper describes the role of the quality assurance liaison, the responsibilities of this position, and the evolutionary changes in duties over the last six years. The role of the quality assurance liaison has had a very positive impact on the Los Alamos Yucca Mountain Site Characterization (YW) quality assurance program. Having both technical and quality assurance expertise, the quality assurance liaisons are able to facilitate communications with scientists on quality assurance issues and requirements, thereby generating greater productivity in scientific investigations. The quality assurance liaisons help ensure that the scientific community knows and implements existing requirements, is aware of new or changing regulations, and is able to conduct scientific work within Project requirements. The influence of the role of the quality assurance liaison can be measured by an overall improvement in attitude of the staff regarding quality assurance requirements and improved job performance, as well as a decrease in deficiencies identified during both internal and external audits and surveillances. This has resulted in a more effective implementation of quality assurance requirements

  15. Environmental restoration remedial action quality assurance requirements document

    International Nuclear Information System (INIS)

    Cote, R.F.

    1991-01-01

    The environmental Restoration Remedial Action Quality Assurance Requirements Document (DOE/RL 90-28) defines the quality assurance program requirements for the US Department of Energy-Richland Field Office Environmental Restoration Remedial Action Program at the Hanford Site, Richland, Washington. This paper describes the objectives outlined in DOE/RL 90-28. The Environmental Restoration Remedial Action Program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency

  16. Quality assurance requirements and description for the Civilian Radioactive Waste Management Program

    International Nuclear Information System (INIS)

    1992-01-01

    The Quality Assurance Requirements and Description (QARD) is the principal quality assurance document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the Quality Assurance Program. The QARD contains regulatory requirements and program commitments necessary for the development of an effective quality assurance program. Quality assurance implementing documents must be based on, and consistent with, QARD requirements. The QARD applies to the following: (1) acceptance of spent nuclear fuel and high-level radioactive waste; (2) transport of spent nuclear fuel and high-level radioactive waste; (3) the Monitored Retrievable Storage (MRS) facility through application for an operating license; (4) Mined Geologic Disposal System (MGDS), including the site characterization activities (exploratory studies facility (ESF) and surface based testing), through application for an operating license; (5) the high-level-waste form from production through acceptance. Section 2.0 defines in greater detail criteria for determining work subject to QARD requirements. The QARD is organized into sections, supplements, appendices, and a glossary. The sections contain requirements that are common to all Program elements. The supplements contain requirements for specialized activities. The appendices contain requirements that are specific to an individual Program element. The glossary establishes a common vocabulary for the Quality Assurance Program

  17. Quality assurance requirements for packaging and transportation of radioactive materials

    International Nuclear Information System (INIS)

    Barker, R.F.; MacDonald, C.E.; Doda, R.J.

    1978-01-01

    This paper discusses the new quality assurance regulations of the Nuclear Regulatory Commission (NRC) for packaging and transportation of radioactive materials. These regulations became effective on October 18, 1977. Background information concerning these regulations and packaging and transportation history is included. The quality assurance program is described with indications of how it is composed of general (administrative) provisions which must meet the 18 quality assurance criteria and be approved by the NRC; specific provisions which appear in the DOT and NRC regulations and in the individual package design approval; and other specific procedures which are not required by regulations but which are necessary for the proper control of quality. The quality assurance program is to be developed using a graded approach for the application of pertinent criteria and optimizing the required degree of safety and control efforts involved in achieving this level of safety. The licensee-user is responsible for all phases of quality assurance for packaging activities including: design, manufacture, test, use, maintenance and repair. The package design phase is considered to be particularly important in producing adequate safety in operational activities concerning packaging and transportation of radioactive materials

  18. The IAEA Code of Practice on quality assurance, and quality assurance requirements and practices in Member States

    International Nuclear Information System (INIS)

    Raisic, N.

    1982-01-01

    The IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the corresponding Safety Guides are reviewed and compared with quality assurance (QA) practices in the IAEA Member States. The QA requirements stipulated by the Code place on the nuclear power plant owner the responsibility to establish an overall QA programme for the plant. In selecting the QA programme level for specific activities, the Code allows of a flexible approach but does not specify gradation in programme requirements. The Code is placing the burden of quality-achieving and quality-assuring functions on the task-performing organizations, namely the designers, manufacturers, constructors and plant operators. The plant owner provides for the management of the overall QA programme, surveillance of activities and verifications of the effectiveness of the constituent programmes of all project participants through programme audits and evaluations. The Code and the supporting Safety Guides are consistent with existing QA practices in Member States. However, certain differences exist, which are mainly expressed in the different QA functions assigned to the various organizations participating in the overall QA programme. Also, some Member States place more emphasis on redundant verification activities than on quality-achieving functions. Tendencies are also identified to grade the QA requirements in respect of items and activities, in accordance with some pre-established criteria. In an annex to the paper, QA practices in Member States participating in the Agency's Technical Review Committee on Quality Assurance (TRC-QA) are reviewed, indicating their similarities to and differences from the Code

  19. Quality assurance

    International Nuclear Information System (INIS)

    Kunich, M.P.; Vieth, D.L.

    1989-01-01

    This paper provides a point/counterpoint view of a quality assurance director and a project manager. It presents numerous aspects of quality assurance requirements along with analyses as to the value of each

  20. Quality assurance program preparation - review of requirements and plant systems - selection of program levels

    International Nuclear Information System (INIS)

    Asmuss, G.

    1980-01-01

    The establishment and implementation for a practicable quality assurance program for a nuclear power plant demands a detailed background in the field of engineering, manufacturing, organization and quality assurance. It will be demonstrated with examples to define and control the achievement of quality related activities during the phases of design, procurement, manufactoring, commissioning and operation. In general the quality assurance program applies to all items, processes and services important to safety of nuclear power plant. The classification for safety related and non-safety related items and services demonstrate the levels of quality assurance requirements. The lecture gives an introduction of QA Program preparation under the following topics: -Basic criteria and international requirements - Interaction of QA activities - Modular and product oriented QA programs - Structuring of organization for the QA program - Identification of the main quality assurance functions and required actions - Quality Assurance Program documentation - Documentation of planning of activities - Control of program documents - Definitions. (orig./RW)

  1. Quality assurance

    International Nuclear Information System (INIS)

    1996-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (NRA SR) was focused on support of quality assurance programmes development at responsible organizations Bohunice V-1 and V-v and Mochovce NPPs and their inspection. Development of the level two documentation of a partial quality assurance programme for NPP operation continued at Mochovce NPP. Most of documentation has been submitted to NRA SR for comments and approval. NRA SR invited a mission of French experts to Mochovce NPP to review preparation and performance of internal audits that would be beneficial for improvement in this kind activities at the NPP. Bohunice NPP continued in development of a partial quality assurance programme for operation. The Quality Assurance Programme submitted to NRA SR for approval. Based on a request of Bohunice NPPs, NRA SR consulted the draft quality assurance programme developed by Siemens for stage of the 'Basic Design' of V-1 NPP upgrading. The programme had not been submitted for approval to NRA SR prior to completion of works by Siemens. Based on an internal audit that had been performed, corrective measures were proposed to meet requirements on review and approval of suppliers quality assurance programmes. Requirements related to the quality assurance at nuclear installations were prepared to be incorporated into principles of a act on peaceful use of nuclear power in Slovak Republic

  2. Quality assurance handbook for measurement laboratories

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1984-10-01

    This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining quality data and the importance of such data are discussed. Chapter 2 presents the elements of laboratory quality assurance in terms of practices that can be used in controlling work activities to assure the acquisition of quality data. Chapter 3 discusses the implementation of laboratory quality assurance. The appendices provide supplemental information to give the users a better understanding of the following: what is quality assurance; why quality assurance is required; where quality assurance requirements come from; how those requirements are interpreted for application to laboratory operations; how the elements of laboratory quality assurance relate to various laboratory activities; and how a quality assurance program can be developed

  3. The 18 basic requirement of quality assurance for American design NPP

    International Nuclear Information System (INIS)

    Baliza, Ana Rosa

    2013-01-01

    On April 17th, 1969, the Atomic Energy Commission (AEC) published in the U.S. Federal Register (FR), Volume 34, Number 73, a proposed amendment to 10CFR50 to insert Appendix B - 'Quality assurance criteria for Nuclear Power Plant'. This Appendix was officially approved on June 27th, 1970 and published in the FR, volume 35, number 125. Appendix B is the Quality Assurance document for U.S. nuclear facilities. This document establishes eighteen basic requirements (BR) to design, construction, manufacture and operation of structures, systems and components (SSC) related to safety. The 18 BR describe 'what' shall be done, but not 'how' to do. In order to standardize the actions of nuclear facilities during 10 CFR 50 App B implementation, the industry has developed some documents, the main ones are: ASME NQA-1 (Quality Assurance Requirements for Nuclear Facility Applications) and the series ANSI N 45.2 (Quality Assurance Program Requirements for Nuclear Facilities). Both documents are approved by the NRC (Nuclear Regulatory Commission). The NRC is the licensing body of U.S. nuclear facilities. In Brazil, the licensing body is CNEN (Comissao Nacional de Energia Nuclear). This paper describes the 18 BR for American Designed Nuclear Power Plant (NPP), applicable to Angra-1 NPP. (author)

  4. Monitoring of performance management using Quality Assurance Indicators and ISO requirement

    Directory of Open Access Journals (Sweden)

    Dargahi H

    2007-06-01

    Full Text Available Background: Quality assurance is a prevention-oriented system that can be used to improve the quality of care, increase productivity and monitor the performance management in clinical laboratories. ISO 9001: 2000 requirements are a collection of management and technical systems designed to implement quality assurance and monitor performance management in organizations. Methods: A checklist was prepared to monitor the preanalytical, analytical and postanalytical stages of laboratory performance management in 16 areas and all laboratory activities in 14 of the clinical laboratories of the Tehran University of Medical Sciences (TUMS hospitals. Collected data were stored and statistically analyzed using SPSS software. Results: The best performance, in which 77.73% of quality assurance indicators were observed, was found in Sina Hospital. However, only 57.56% of these indicators were fulfilled at Farabi Hospital, with the lowest-level performance among the clinical laboratories of TUMS hospitals. The highest level of compliance with quality assurance indicators was in the hematology departments and for facility demands in management areas. Overall, quality assurance indicators were appropriately followed in only 7% of the clinical laboratories. Conclusion: The average quality assurance observation rate in the clinical laboratories studied was 67.22%, which is insufficient and must be remedied with stricter enforcement of the ISO 9001: 2000 regulations.

  5. The application of quality assurance

    International Nuclear Information System (INIS)

    Lovatt, G.B.

    1988-01-01

    The paper concerns the application of quality assurance to structures, systems and components for the design, construction and operation of nuclear power plant and fuel reprocessing plant. A description is given of:- the requirements for quality assurance, the establishment of quality assurance arrangements, quality assurance documents structure, and quality assurance manuals and programmes. Quality assurance procedures and auditing are also discussed. (U.K.)

  6. Quality assurance requirements for dedication process in Angra 1

    Energy Technology Data Exchange (ETDEWEB)

    Baliza, Ana Rosa, E-mail: baliza@eletronuclear.gov.br [Eletrobras Termonuclear S.A. (ELETRONUCLEAR), Angra dos Reis, RJ (Brazil). Departamento GQO.G; Morghi, Youssef, E-mail: ymo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil)

    2015-07-01

    In Brazil the regulatory body is CNEN (Comissao Nacional de Energia Nuclear), according to its requirements, when there is not a Brazilian standard, the utilities shall follow the requirements of the designer. For Angra 1, the designer is an American company - Westinghouse. So, the requirements for dedication of U.S. NRC (United States Nuclear Regulatory Commission) shall be applied, these requirements are in 10CFR21 - Reporting of Defects and Noncompliance. According to 10CFR21, when applied to nuclear power plants licensed dedication is an acceptance process undertaken to provide reasonable assurance that a commercial grade item to be used as a basic component will perform its intended safety function and, in this respect, is deemed equivalent to an item designed and manufactured under a quality assurance program standard for nuclear power plant. This assurance is achieved by identifying the critical characteristics of the item and verifying their acceptability by inspections, tests, or analyses by the purchaser or third-party dedicating entity. (author)

  7. Quality assurance requirements for dedication process in Angra 1

    International Nuclear Information System (INIS)

    Baliza, Ana Rosa

    2015-01-01

    In Brazil the regulatory body is CNEN (Comissao Nacional de Energia Nuclear), according to its requirements, when there is not a Brazilian standard, the utilities shall follow the requirements of the designer. For Angra 1, the designer is an American company - Westinghouse. So, the requirements for dedication of U.S. NRC (United States Nuclear Regulatory Commission) shall be applied, these requirements are in 10CFR21 - Reporting of Defects and Noncompliance. According to 10CFR21, when applied to nuclear power plants licensed dedication is an acceptance process undertaken to provide reasonable assurance that a commercial grade item to be used as a basic component will perform its intended safety function and, in this respect, is deemed equivalent to an item designed and manufactured under a quality assurance program standard for nuclear power plant. This assurance is achieved by identifying the critical characteristics of the item and verifying their acceptability by inspections, tests, or analyses by the purchaser or third-party dedicating entity. (author)

  8. Data Quality Assurance Governance

    OpenAIRE

    Montserrat Gonzalez; Stephanie Suhr

    2016-01-01

    This deliverable describes the ELIXIR-EXCELERATE Quality Management Strategy, addressing EXCELERATE Ethics requirement no. 5 on Data Quality Assurance Governance. The strategy describes the essential procedures and practices within ELIXIR-EXCELERATE concerning planning of quality management, performing quality assurance and controlling quality. It also depicts the overall organisation of ELIXIR with emphasis on authority and specific responsibilities related to quality assurance.

  9. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activities and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities wihtin the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  10. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activitie and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities within the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  11. 10 CFR 74.59 - Quality assurance and accounting requirements.

    Science.gov (United States)

    2010-01-01

    ... measurement system in question must not be used for material control and accounting purposes until it has been... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance and accounting requirements. 74.59 Section 74.59 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) MATERIAL CONTROL AND ACCOUNTING OF SPECIAL...

  12. 30 CFR 74.9 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 74.9 Section 74.9 Mineral... DUST SAMPLING DEVICES Requirements for Continuous Personal Dust Monitors § 74.9 Quality assurance. (a) General requirements. The applicant shall establish and maintain a quality control system that assures...

  13. Guide for reviewing safety analysis reports for packaging: Review of quality assurance requirements

    International Nuclear Information System (INIS)

    Moon, D.W.

    1988-10-01

    This review section describes quality assurance requirements applying to design, purchase, fabrication, handling, shipping, storing, cleaning, assembly, inspection, testing, operation, maintenance, repair, and modification of components of packaging which are important to safety. The design effort, operation's plans, and quality assurance requirements should be integrated to achieve a system in which the independent QA program is not overly stringent and the application of QA requirements is commensurate with safety significance. The reviewer must verify that the applicant's QA section in the SARP contains package-specific QA information required by DOE Orders and federal regulations that demonstrate compliance. 8 refs

  14. Quality assurance requirements and methods for high level waste package acceptability

    International Nuclear Information System (INIS)

    1992-12-01

    This document should serve as guidance for assigning the necessary items to control the conditioning process in such a way that waste packages are produced in compliance with the waste acceptance requirements. It is also provided to promote the exchange of information on quality assurance requirements and on the application of quality assurance methods associated with the production of high level waste packages, to ensure that these waste packages comply with the requirements for transportation, interim storage and waste disposal in deep geological formations. The document is intended to assist both the operators of conditioning facilities and repositories as well as national authorities and regulatory bodies, involved in the licensing of the conditioning of high level radioactive wastes or in the development of deep underground disposal systems. The document recommends the quality assurance requirements and methods which are necessary to generate data for these parameters identified in IAEA-TECDOC-560 on qualitative acceptance criteria, and indicates where and when the control methods can be applied, e.g. in the operation or commissioning of a process or in the development of a waste package design. Emphasis is on the control of the process and little reliance is placed on non-destructive or destructive testing. Qualitative criteria, relevant to disposal of high level waste, are repository dependent and are not addressed here. 37 refs, 3 figs, 2 tabs

  15. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    2006-01-01

    The WMG QAP is an integral part of a management system designed to ensure that WMG activities are planned, performed, documented, and verified in a manner that assures a quality product. A quality product is one that meets all waste acceptance criteria, conforms to all permit and regulatory requirements, and is accepted at the offsite treatment, storage, and disposal facility. In addition to internal processes, this QA Plan identifies WMG processes providing oversight and assurance to line management that waste is managed according to all federal, state, and local requirements for waste generator areas. A variety of quality assurance activities are integral to managing waste. These QA functions have been identified in the relevant procedures and in subsequent sections of this plan. The WMG QAP defines the requirements of the WMG quality assurance program. These requirements are derived from Department of Energy (DOE) Order 414.1C, Quality Assurance, Contractor Requirements Document, the LBNL Operating and Assurance Program Plan (OAP), and other applicable environmental compliance documents. The QAP and all associated WMG policies and procedures are periodically reviewed and revised, as necessary, to implement corrective actions, and to reflect changes that have occurred in regulations, requirements, or practices as a result of feedback on work performed or lessons learned from other organizations. The provisions of this QAP and its implementing documents apply to quality-affecting activities performed by the WMG; WMG personnel, contractors, and vendors; and personnel from other associated LBNL organizations, except where such contractors, vendors, or organizations are governed by their own WMG-approved QA programs

  16. Quality-Assurance Program Plan

    International Nuclear Information System (INIS)

    Kettell, R.A.

    1981-05-01

    This Quality Assurance Program Plan (QAPP) is provided to describe the Quality Assurance Program which is applied to the waste management activities conducted by AESD-Nevada Operations at the E-MAD Facility located in Area 25 of the Nevada Test Site. The AESD-Nevada Operations QAPP provides the necessary systematic and administrative controls to assure activities that affect quality, safety, reliability, and maintainability during design, procurement, fabrication, inspection, shipments, tests, and storage are conducted in accordance with established requirements

  17. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Dommke, J.; Jurgutat, H.

    1980-01-01

    During the time of planing and construction of a nuclear power plant, the following proceeding is approved: - the deliverer of a nuclear power plant provides the reports fixing the quality assurance program, it means that he is responsible to write the safety analysis report, the specifications for the erection of the components, the working manuals and specifications for testing (eg nondestr. testing) - the manufacturing of components or systems will be controlled by an own independent quality assurance group, provided that this group was checked by the quality assurance group of the applicant - the TUeV with its independent assessors will fix the requirements relating to quality assurance in its assessment. On this basis the examination of the applicants specifications, working manuals, testing specifications will be done. The efficiency of quality assurance at the manufacturer and at the applicant will be checked by the TUeV specialists by considering specifications of modifications, repairs or tolerances. A mean point of the quality assurance in Germany is the dynamic adjustment, of an action on the latest state of engineering or science. If there exists a change of rules or guidelines, the quality assurance requirements have to be fit on this state in so far as it is feasible from the technical point of view. (orig./RW)

  18. RAVEN Quality Assurance Activities

    Energy Technology Data Exchange (ETDEWEB)

    Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report discusses the quality assurance activities needed to raise the Quality Level of Risk Analysis in a Virtual Environment (RAVEN) from Quality Level 3 to Quality Level 2. This report also describes the general RAVEN quality assurance activities. For improving the quality, reviews of code changes have been instituted, more parts of testing have been automated, and improved packaging has been created. For upgrading the quality level, requirements have been created and the workflow has been improved.

  19. 40 CFR 31.45 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 31.45 Section 31.45... Requirements Reports, Records, Retention, and Enforcement § 31.45 Quality assurance. If the grantee's project... quality assurance practices consisting of policies, procedures, specifications, standards, and...

  20. Bruce Power's nuclear pressure boundary quality assurance program requirements, implementation and transition

    International Nuclear Information System (INIS)

    Krane, J.C.

    2009-01-01

    The development of a full scope nuclear pressure boundary quality assurance program in Canada requires extensive knowledge of the structure and detailed requirements of codes and standards published by the Canadian Standards Association (CSA) and American Society of Mechanical Engineers (ASME). Incorporation into company governance documents and implementation of these requirements while managing the transition to more recent revisions of these codes and standards represents a significant challenge for Bruce Power, Canada's largest independent nuclear operator. This paper explores the key developments and innovative changes that are used to ensure successful regulatory compliance and effective implementation of the Bruce Power Pressure Boundary Quality Assurance Program. Challenges and mitigating strategies to sustain this large compliance based program at Bruce Power's 8 unit nuclear power plant site will also be detailed. (author)

  1. Quality assurance considerations in nuclear waste management

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1982-01-01

    Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are carried out as specific actions during the life of the project

  2. 40 CFR 30.54 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 30.54 Section 30.54... NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.54 Quality assurance. If the... data generation, the grantee shall develop and implement quality assurance practices consisting of...

  3. Quality assurance requirements for the computer software and safety analyses

    International Nuclear Information System (INIS)

    Husarecek, J.

    1992-01-01

    The requirements are given as placed on the development, procurement, maintenance, and application of software for the creation or processing of data during the design, construction, operation, repair, maintenance and safety-related upgrading of nuclear power plants. The verification and validation processes are highlighted, and the requirements put on the software documentation are outlined. The general quality assurance principles applied to safety analyses are characterized. (J.B.). 1 ref

  4. Quality assurance of fuel elements

    International Nuclear Information System (INIS)

    Hoerber, J.

    1980-01-01

    The quality assurance activities for reactor fuel elements are based on a quality assurance system which implies the requirements resulting from the specifications, regulations of the authorities, national standards and international rules and regulations. The quality assurance related to production of reactor fuel will be shown for PWR fuel elements in all typical fabrication steps as conversion into UO 2 -powder, pelletizing, rodmanufacture and assembling. A wide range of destructive and nondestructive techniques is applied. Quality assurance is not only verified by testing techniques but also by process monitoring by means of parameter control in production and testing procedures. (RW)

  5. Quality assurance requirements for the operation of Swedish nuclear power plants

    International Nuclear Information System (INIS)

    1983-09-01

    An adaption of NRC's 10 CFR 50, Appendis B (Quality Assurance Criteria for Nuclear Power and Fuel Reprocessing Plants) to Swedish conditions is presented. No references are given to regulations standards etc that influence the requirements and their adaption to local conditions. (Aa)

  6. Hanford analytical services quality assurance requirements documents. Volume 1: Administrative Requirements

    International Nuclear Information System (INIS)

    Hyatt, J.E.

    1997-01-01

    Hanford Analytical Services Quality Assurance Requirements Document (HASQARD) is issued by the Analytical Services, Program of the Waste Management Division, US Department of Energy (US DOE), Richland Operations Office (DOE-RL). The HASQARD establishes quality requirements in response to DOE Order 5700.6C (DOE 1991b). The HASQARD is designed to meet the needs of DOE-RL for maintaining a consistent level of quality for sampling and field and laboratory analytical services provided by contractor and commercial field and laboratory analytical operations. The HASQARD serves as the quality basis for all sampling and field/laboratory analytical services provided to DOE-RL through the Analytical Services Program of the Waste Management Division in support of Hanford Site environmental cleanup efforts. This includes work performed by contractor and commercial laboratories and covers radiological and nonradiological analyses. The HASQARD applies to field sampling, field analysis, and research and development activities that support work conducted under the Hanford Federal Facility Agreement and Consent Order Tri-Party Agreement and regulatory permit applications and applicable permit requirements described in subsections of this volume. The HASQARD applies to work done to support process chemistry analysis (e.g., ongoing site waste treatment and characterization operations) and research and development projects related to Hanford Site environmental cleanup activities. This ensures a uniform quality umbrella to analytical site activities predicated on the concepts contained in the HASQARD. Using HASQARD will ensure data of known quality and technical defensibility of the methods used to obtain that data. The HASQARD is made up of four volumes: Volume 1, Administrative Requirements; Volume 2, Sampling Technical Requirements; Volume 3, Field Analytical Technical Requirements; and Volume 4, Laboratory Technical Requirements. Volume 1 describes the administrative requirements

  7. Quality assurance in the nuclear industry

    International Nuclear Information System (INIS)

    Knoedler, D.

    1978-01-01

    Quality assurance is the sum of all activities systematically planned, practiced, and controlled with the aim to assure the quality of deliveries and performances. This assurance today covers all phases of activities, from the planning (including a determination of the required and necessary quality characteristics) to the start-up of a plant. (orig./RW) [de

  8. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-03-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of airborne emissions. The Hanford Site radioactive airborne emissions requirements are defined in National Emissions Standards for Hazardous Air Pollutants (NESHAP), Code of Federal Regulations, Title 40, Part 61, Subpart H (EPA 1991a). Reporting of the emissions to the US Department of Energy is performed in compliance with requirements of US Department of Energy, Richland Operations Office Order 5400.1, General Environmental Protection Program (DOE-RL 1988). This Quality Assurance Program Plan is prepared in accordance with and to the requirements of QAMS-004/80, Guidelines and Specifications for Preparing Quality Assurance Program Plans (EPA 1983). Title 40 CFR Part 61, Appendix B, Method 114, Quality Assurance Methods (EPA 1991b) specifies the quality assurance requirements and that a program plan should be prepared to meet the requirements of this regulation. This Quality Assurance Program Plan identifies NESHAP responsibilities and how the Westinghouse Hanford Company Environmental, Safety, Health, and Quality Assurance Division will verify that the methods are properly implemented

  9. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    2003-03-01

    Good radiotherapy results and safety of treatment require the radiation to be optimally applied to a specified target area and the correct dose. According to international recommendations, the average uncertainty in therapeutic dose should not exceed 5%. The need for high precision in therapeutic dose requires quality assurance covering the entire radiotherapy process. Besides the physical and technical characteristics of the therapy equipment, quality assurance must include all radiotherapy equipment and procedures that are significant for the correct magnitude and precision of application of the therapeutic dose. The duties and responsibilities pertaining to various stages of treatment must also be precisely defined. These requirements may be best implemented through a quality system. The general requirements for supervision and quality assurance of medical radiation apparatus are prescribed in section 40 of the Radiation Act (592/1991, amendment 1142/1998) and in sections 18 and 32 of the Decree of the Ministry of Social Affairs and Health on the medical use of radiation (423/2000). Guide ST 2.2 imposes requirements on structural radiation shielding of radiotherapy equipment and the premises in which it is used, and on warning and safety arrangements. Guide ST 1.1 sets out the general safety principles for radiation practices and regulatory control procedure for the use of radiation. Guide ST 1.6 provides general requirements for operational measures in the use of radiation. This Guide sets out the duties of responsible parties (the party running a radiation practice) in respect of arranging and maintaining radiotherapy quality assurance. The principles set out in this Guide and Guide ST 6.3 may be applied to radionuclide therapy

  10. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Kaul, A.

    1986-01-01

    'Quality Assurance in Nuclear Medicine' is the title of the English language original that has been translated into German. The manual very extensively deals with quality control of nuclear medical equipment. Tests are explained for checking radioactivity measuring devices, manual and automatic in-vitro sample measuring systems, in-vivo measuring systems with single or multiple detectors, rectlinear scanners, and gamma cameras, including the phantoms required for the methods. Other chapters discuss the quality control of radiopharmaceuticals, or the quality assurance in data recording and evaluation of results. Helpful comments on the organisation of quality assurance programms are given. The book is intended as a practical guide for introducing quality assurance principles in nuclear medicine in the Federal Republic of Germany. With 13 figs., 22 tabs [de

  11. Overall quality assurance program requirements for nuclear power plants

    International Nuclear Information System (INIS)

    1992-09-01

    This standard contains the requirements for the owner's overall quality assurance program for a nuclear power plant. This program encompasses all phases of a nuclear power plant life cycle, including site evaluation, design, procurement, manufacturing, construction and installation, commissioning, operation, and decommissioning. It covers the activities associated with specifying, directing, and administering the work to be done during these phases, and the evaluation and integrated of the activities and programs of participants

  12. Project Specific Quality Assurance Plan

    International Nuclear Information System (INIS)

    Pedersen, K.S.

    1995-01-01

    This Quality Assurance Project Plan (QAPP) identifies the Westinghouse Hanford Co. (WHC) Quality Assurance (QA) program requirements for all contractors involved in the planning and execution of the design, construction, testing and inspection of the 200 Area Effluent BAT/AKART Implementation, Project W-291

  13. Quality assurance program plan for Building 324

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides an overview of the quality assurance program for Building 324. This plan supersedes the PNNL Nuclear Facilities Quality Management System Description, PNL-NF-QMSD, Revision 2, dated March 1996. The program applies to the facility safety structures, systems, and components and to activities that could affect safety structures, systems, and components. Adherence to the quality assurance program ensures the following: US Department of Energy missions and objectives are effectively accomplished; Products and services are safe, reliable, and meet or exceed the requirements and expectations of the user; Hazards to the public, to Hanford Site and facility workers, and to the environment are minimized. The format of this Quality Assurance Program Plan is structured to parallel that of 10 CFR 83 0.120, Quality Assurance Requirements

  14. Quality assurance within regulatory bodies

    International Nuclear Information System (INIS)

    1999-06-01

    The IAEA directed extensive efforts during the years 1991 to 1995 to the integral revision of all NUSS quality assurance publications, which were approved and issued as Safety Series No.50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations (1996). When these quality assurance publications were developed, their prime focus was on requirements against which work performed by the licensees could be measured and assessed by the regulatory bodies. In this way, they only helped to facilitate the functions of regulators. No requirements or recommendations were provided on how the regulators should ensure the effective implementation of their own activities. The present publication is a first attempt to collect, integrate and offer available experience to directly support performance of regulatory activities. It presents a comprehensive compilation on the application of quality assurance principles and methods by regulatory bodies to their activities. The aim is consistent good performance of regulatory activities through a systematic approach

  15. 40 CFR 194.22 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... General Requirements § 194.22 Quality assurance. (a)(1) As soon as practicable after April 9, 1996, the Department shall adhere to a quality assurance program that implements the requirements of ASME NQA-1-1989... elicitation used to support applications for certification or re-certification of compliance; (vi) Design of...

  16. Methods of Software Quality Assurance under a Nuclear Quality Assurance Program

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cha, Kyung Ho; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2005-01-01

    This paper addresses a substantial implementation of a software quality assurance under a nuclear quality assurance program. The relationship of the responsibility between a top-level nuclear quality assurance program such as ASME/NQA-1 and its lower level software quality assurance is described. Software quality assurance activities and software quality assurance procedures during the software development life cycle are also described

  17. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  18. Framework for the quality assurance of 'omics technologies considering GLP requirements.

    Science.gov (United States)

    Kauffmann, Hans-Martin; Kamp, Hennicke; Fuchs, Regine; Chorley, Brian N; Deferme, Lize; Ebbels, Timothy; Hackermüller, Jörg; Perdichizzi, Stefania; Poole, Alan; Sauer, Ursula G; Tollefsen, Knut E; Tralau, Tewes; Yauk, Carole; van Ravenzwaay, Ben

    2017-12-01

    'Omics technologies are gaining importance to support regulatory toxicity studies. Prerequisites for performing 'omics studies considering GLP principles were discussed at the European Centre for Ecotoxicology and Toxicology of Chemicals (ECETOC) Workshop Applying 'omics technologies in Chemical Risk Assessment. A GLP environment comprises a standard operating procedure system, proper pre-planning and documentation, and inspections of independent quality assurance staff. To prevent uncontrolled data changes, the raw data obtained in the respective 'omics data recording systems have to be specifically defined. Further requirements include transparent and reproducible data processing steps, and safe data storage and archiving procedures. The software for data recording and processing should be validated, and data changes should be traceable or disabled. GLP-compliant quality assurance of 'omics technologies appears feasible for many GLP requirements. However, challenges include (i) defining, storing, and archiving the raw data; (ii) transparent descriptions of data processing steps; (iii) software validation; and (iv) ensuring complete reproducibility of final results with respect to raw data. Nevertheless, 'omics studies can be supported by quality measures (e.g., GLP principles) to ensure quality control, reproducibility and traceability of experiments. This enables regulators to use 'omics data in a fit-for-purpose context, which enhances their applicability for risk assessment. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. 222-S Laboratory Quality Assurance Plan. Revision 1

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A quality assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document

  20. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  1. Commissioning quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig.

  2. Commissioning quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig

  3. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  4. Quality assurance systems at SKODA JS

    International Nuclear Information System (INIS)

    Janecek, P.

    2000-01-01

    In addition to technical requirements put upon the design, manufacture, installation and commissioning of equipment for nuclear power plants, emphasis is laid upon quality assurance of such activities so as to secure nuclear safety of installations over the world. As the technical level of nuclear safety assurance is being enhanced continuously, the requirements are becoming more and more stringent, which is mirrored by the relevant standards and legislation. SKODA JS has always been pursuing the quality goal and has been contributing to this aspect markedly. The quality assurance system at SKODA JS helps the company to satisfy all the appropriate requirements of its customers as well as the applicable standards and regulations. (author)

  5. Quality assurance of polymer concrete

    International Nuclear Information System (INIS)

    Schulz, H.

    1984-01-01

    With polymer concrete, a whole range of organisational and functional measures have to be met in order to assure the required quality with an economic expenditure. Quality assurance begins in the design and does not end in the production, rather includes all fields of the enterprise. The following deals with a particular range of the total complex, the inspection methods for assuring the quality of machine components of polymer concrete, particularly machine tool bases, this being through the control of the raw material, the production and the finished product. (orig.) [de

  6. Towards improvement in quality assurance

    International Nuclear Information System (INIS)

    1987-03-01

    This first document in the series of the International Nuclear Safety Advisory Group (INSAG) Technical Notes is a general guideline for the establishment of effective quality assurance procedures at nuclear facilities. It sets out primary requirements such as quality objectives, methods for measuring the effectiveness of the quality assurance programme, priority of activities in relation to importance of safety of items, motivation of personnel

  7. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-12-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of radiological airborne emissions. This Quality Assurance Program Plan is prepared in accordance with and to written requirements

  8. Requirements for auditing of quality assurance programs for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Requirements and guidance are provided for establishing and implementing a system of internal and external audits of quality assurance programs for nuclear power plants, including the preparation, performance, reporting and follow-up of audits by both the auditing and the audited organizations. This standard is to be used in conjunction with ANSI N45.2

  9. Manpower requirements of quality assurance personnel for the nuclear power plants

    International Nuclear Information System (INIS)

    Aly, A.E.; El-sayed, A.A.; Shabaan, I.H.

    1987-01-01

    Basic principles for structuring and staffing of the quality assurance (Q.A.)organisation in the nuclear power plant (NPP) are presented. the manpower requirements of the Q.A.organisation in the NPP during both construction and operational stages are determined. the manpower requirements for Q.A./Q.C. functions in a NPP are found to be proportional to the number of craft workers needed to perform the required level of the construction. The Q.A./Q.C. personnel are about 15% of the total number of the craft workers required during construction

  10. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    1993-01-01

    Lawrence Berkeley Laboratory's Environment Department addresses its responsibilities through activities in a variety of areas. The need for a comprehensive management control system for these activities has been identified by the Department of Energy (DOE). The WM QA (Waste Management Quality Assurance) Plan is an integral part of a management system that provides controls necessary to ensure that the department's activities are planned, performed, documented, and verified. This WM QA Plan defines the requirements of the WM QA program. These requirements are derived from DOE Order 5700.6C, Quality Assurance, the LBL Operating and Assurance Program Plan (OAP, LBL PUB-3111), and other environmental compliance documents applicable to WM activities. The requirements presented herein, as well as the procedures and methodologies that direct the implementation of these requirements, will undergo review and revisions as necessary. The provisions of this QA Plan and its implementing documents apply to quality-affecting activities performed by and for WM. It is also applicable to WM contractors, vendors, and other LBL organizations associated with WM activities, except where such contractors, vendors, or organizations are governed by their own WM-approved QA programs. References used in the preparation of this document are (1) ASME NQA-1-1989, (2) ANSI/ASQC E4 (Draft), (3) Waste Management Quality Assurance Implementing Management Plan (LBL PUB-5352, Rev. 1), (4) LBL Operating and Assurance Program Plan (OAP), LBL PUB-3111, 2/3/93. A list of terms and definitions used throughout this document is included as Appendix A

  11. Quality Assurance - Construction

    DEFF Research Database (Denmark)

    Gaarslev, Axel

    1996-01-01

    Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies......Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies...

  12. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    , on the one hand, to advance internationalisation of quality assurance of higher education, and on the other hand, allow for the differences in the national approaches to quality assurance. The paper will focus on two issues: first, the strength and weaknesses of the method employed and of the use of the ENQA......The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the need...

  13. Quality assurance program plan fuel supply shutdown project

    International Nuclear Information System (INIS)

    Metcalf, I.L.

    1998-01-01

    This Quality Assurance Program plan (QAPP) describes how the Fuel Supply Shutdown (FSS) project organization implements the quality assurance requirements of HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) and the B and W Hanford Company Quality Assurance Program Plan (QAPP), FSP-MP-004. The QAPP applies to facility structures, systems, and components and to activities (e.g., design, procurement, testing, operations, maintenance, etc.) that could affect structures, systems, and components. This QAPP also provides a roadmap of applicable Project Hanford Policies and Procedures (PHPP) which may be utilized by the FSS project organization to implement the requirements of this QAPP

  14. Quality assurance - not only for engineers

    International Nuclear Information System (INIS)

    Treffner, F.W.

    1984-01-01

    The actual purpose of quality assurance is the definition of effective processes, ways and means of planning, fabricating and obtaining the required characteristics determining the quality of components, subsystems and their fabrication techniques at any place and any time. Service companies can contribute quality assurance, quality control and documentation work do cost-benefit analyses and act as expert consultants. (orig.) [de

  15. Elements of quality assurance in environmental surveillance

    International Nuclear Information System (INIS)

    Johnson, L.J.

    1975-01-01

    Qualities of an environmental surveillance program requiring control or assurance are reviewed. Requirements of accuracy, reproducibility, sensitivity, acceptability, and time and cost effectiveness are qualities discussed. The controls applicable to sample collection, handling, chemical analysis, measurement and data presentation are identified and discussed as they pertain to environmental monitoring. Quality assurance program recommendations for developing and reporting environmental surveillance data are provided

  16. Quality assurance records system

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (IAEA Safety Series No.50-C-QA), which requires that for each nuclear power plant a system for the generation, identification, collection, indexing, filing, storing, maintenance and disposition of quality assurance records shall be established and executed in accordance with written procedures and instructions. The purpose of this Safety Guide is to provide assistance in the establishment and operation of such a system. An orderly established and maintained records system is considered to be part of the means of providing a basis for an appropriate level of confidence that the activities which affect the quality of a nuclear power plant have been performed in accordance with the specific requirements and that the required quality has been achieved and is maintained

  17. [Integrated quality assurance].

    Science.gov (United States)

    Bögel, K; Stöhr, K

    1994-07-01

    The definition of terms and connotation of "Quality", "Quality Assurance" and "Integration" lead to an analysis and understanding of inhibiting and fostering factors of the "Health Triad" of people, animals and environment. Although "Quality" is largely or ultimately determined by the consumer, there are considerable differences as this term is applied by (a) the individual consumer, (b) the dynamic producer defending or gaining markets, (c) those engaged in traditional product manufacturing, or (d) governments setting (minimum) requirements for the sake of free trade. "Quality Assurance" offers cooperation of partners all along the food chain from "pasture to table". The managerial process turned into a continuum of responsibility and agreement on processes and product characteristics. This overcomes the disadvantages of strategies stressing distinct defense barriers. In practice this philosophy of a predominant role of defence barriers proved largely partnership destructive, in that it permitted to shift responsibilities for failures and to claim administrative competence according to momentary situations and interests. "Integrated Quality Assurance" means mutual agreement of two or more partners along the food chain (e. g. feed producers, farmers, animal health industry, veterinarians and food processors) on product characteristics and production methods. It involves essential system elements including facilities, materials, manpower, information, transport, management etc. Different principles and procedures of quality assurance have been introduced in practice, including agriculture and food processing. These different approaches are not mutually exclusive but largely of complementary nature.(ABSTRACT TRUNCATED AT 250 WORDS)

  18. Impact of extreme load requirements and quality assurance on nuclear power plant costs

    International Nuclear Information System (INIS)

    Stevenson, J.D.

    1993-01-01

    Definitive costs, applicable to nuclear power plant concrete structures, as a function of National Regulatory Requirements, standardization, the effect of extreme load design associated with both design basis accidents and extreme external events and quality assurance are difficult to develop since such effects are interrelated and not only differ widely from country to country, project to project but also vary in time. Table 1 shows an estimate of the of the overall plant cost effects of external event extreme load design on nuclear power plant design for the U.S -and selected foreign countries for which experience with LWRs exist- Germany is the most expensive primarily due to a military aircraft crash resistance. However, the German requirement for 4 safeguards trains rather than 2 and the containment design requirement to consider one Steam Generator blowdown concurrent with a RCS blowdown. This presentation will concentrate on the direct current impact extreme load design and quality assurance have on concrete structures, systems and components for nuclear plants. This presentation is considered timely due to the increased interest in the c potential backfit of Eastern European nuclear power stations of the WWER 440 and WWER 1000 types which typically did not consider the extreme loads identified in Table 1 and accident loads in Table 3 and quality assurance in Table 5 in their original design. Concrete structures in particular are highlighted because they typically form the last barrier to radioactive release from the containment and other Safety Related Structures

  19. Good manufacturing practice - quality assurance programs

    International Nuclear Information System (INIS)

    Masefield, John; Thompson, Steven

    1986-01-01

    The concept of good manufacturing practice (GMP) in the medical device industry requires the use of controlled methods and equipment in performing each step in the device manufacturing process. Quality assurance programs are used to maintain compliance with GMP requirements by prescribing the operating and control procedures to be used. The specific elements of a quality assurance program for the radiation sterilization of medical devices are described. (author)

  20. Comparative analysis of quality assurance requirements for selected LMFBR components of classes 1, 2 and 3

    International Nuclear Information System (INIS)

    Kleinert, K.P.

    1992-01-01

    The study analyses and compares German, French, British and Italian practices and procedures applied for various LMFBR projects both related to the quality assurance system and related to the particular type of class of component:Class 1: primary reactor vessel; Class 2: Secondary sodium pump; Class 3: Primary cold trap. Various areas of analysis and comparison were selected to identify the underlying concepts of grading of requirements and measures, to identify the similarities and differences, and to give recommendations for further actions concerning quality assurance requirements 60 refs., 21 tabs., 6 figs

  1. Current conceptions of industrial quality assurance

    International Nuclear Information System (INIS)

    Zeller, H.

    1978-01-01

    In the electrical engineering industry quality assurance is mainly oriented in accordance with the customers', users', and consumers' requirements concerning the quality of products (including reliability). These requirements are as manifold as the range of products itself. They do not only comprise functional criteria, but also safety against malfunctions, bodily injury or property damage. Quality assurance is embedded in the overall activities of a company; the peripheral conditions, such as organization, profitability, qualification, and responsibility of staff have to be considered. Thus, quality assurance in the electrical engineering industry proceeds in efficient systems which are adapted to the individual forms of production. These systems may include planning, testing, feedback of quality data, statistical procedures, costs and profitability. Their obvious interaction is based on the system of coordinates of integrated quality control. The paper will illustrate the basic features of this interaction by reference to various examples. (orig.) [de

  2. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the nee...

  3. Ontario's Quality Assurance Framework: A Critical Response

    Science.gov (United States)

    Heap, James

    2013-01-01

    Ontario's Quality Assurance Framework (QAF) is reviewed and found not to meet all five criteria proposed for a strong quality assurance system focused on student learning. The QAF requires a statement of student learning outcomes and a method and means of assessing those outcomes, but it does not require that data on achievement of intended…

  4. SWiFT Software Quality Assurance Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    This document describes the software development practice areas and processes which contribute to the ability of SWiFT software developers to provide quality software. These processes are designed to satisfy the requirements set forth by the Sandia Software Quality Assurance Program (SSQAP). APPROVALS SWiFT Software Quality Assurance Plan (SAND2016-0765) approved by: Department Manager SWiFT Site Lead Dave Minster (6121) Date Jonathan White (6121) Date SWiFT Controls Engineer Jonathan Berg (6121) Date CHANGE HISTORY Issue Date Originator(s) Description A 2016/01/27 Jon Berg (06121) Initial release of the SWiFT Software Quality Assurance Plan

  5. R D software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Hood, F.C.

    1991-10-01

    Research software quality assurance (QA) requirements must be adequate to strengthen development or modification objectives, but flexible enough not to restrict creativity. Application guidelines are needed for the different kinds of research and development (R D) software activities to assure project objectives are achieved.

  6. Westinghouse Water Reactor Divisions quality assurance plan

    International Nuclear Information System (INIS)

    1977-09-01

    The Quality Assurance Program used by Westinghouse Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements. This program satisfies the NRC Quality Assurance Criteria, 10CFR50 Appendix B, to the extent that these criteria apply to safety related NSSS equipment. Also, it follows the regulatory position provided in NRC regulatory guides and the requirements of ANSI Standard N45.2.12 as identified in this Topical Report

  7. [Quality assurance in human genetic testing].

    Science.gov (United States)

    Stuhrmann-Spangenberg, Manfred

    2015-02-01

    Advances in technical developments of genetic diagnostics for more than 50 years, as well as the fact that human genetic testing is usually performed only once in a lifetime, with additional impact for blood relatives, are determining the extraordinary importance of quality assurance in human genetic testing. Abidance of laws, directives, and guidelines plays a major role. This article aims to present the major laws, directives, and guidelines with respect to quality assurance of human genetic testing, paying careful attention to internal and external quality assurance. The information on quality assurance of human genetic testing was obtained through a web-based search of the web pages that are referred to in this article. Further information was retrieved from publications in the German Society of Human Genetics and through a PubMed-search using term quality + assurance + genetic + diagnostics. The most important laws, directives, and guidelines for quality assurance of human genetic testing are the gene diagnostics law (GenDG), the directive of the Federal Medical Council for quality control of clinical laboratory analysis (RiliBÄK), and the S2K guideline for human genetic diagnostics and counselling. In addition, voluntary accreditation under DIN EN ISO 15189:2013 offers a most recommended contribution towards quality assurance of human genetic testing. Legal restraints on quality assurance of human genetic testing as mentioned in § 5 GenDG are fulfilled once RiliBÄK requirements are followed.

  8. Quality assurance during operation of nuclear power plants

    International Nuclear Information System (INIS)

    1994-01-01

    The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.)

  9. Revision of Krsko NPP Quality Assurance Plan

    International Nuclear Information System (INIS)

    Biscan, R.; Fifnja, I.; Kavsek, D.

    2012-01-01

    International standards from nuclear power plant operation area are being frequently upgraded and revised in accordance with the continuous improvement philosophy. This philosophy applies also to the area of Quality Assurance, which has also undergone significant improvement since the early 1950s. Besides just nuclear industry, there are also other international quality standards that are being continuously developed and revised, bringing needs for upgrades also in the nuclear application. Since the beginning of Krsko NPP construction, the overall Quality Assurance program and its applicable procedures were in place to assure that all planned and systematic actions necessary to provide adequate confidence that an item or service will satisfy given requirements to quality, are in place. The overall requirements for quality as one of the major objectives for Krsko NPP operation are also set forth in the Updated Safety Analyses Report, the document that serves as a base for operating license. During more than 30 years of Krsko NPP operation, the quality requirements and related documents were revised and upgraded in several attempts. The latest revision 6 of QD-1, Quality Assurance Plan was issued during the year 2011. The bases for the revision were: Changes of the Slovenian regulatory requirements (ZVISJV, JV5, JV9?), Changes of Krsko NPP licensing documents (USAR section 13?), SNSA inspection requirements, Changes of international standards (IAEA, ISO?), Conclusions of first PSR, Implementation of ISO standards in Krsko NPP (ISO14001, ISO17025), Changes of plant procedures, etc. One of the most obvious changes was the enlargement of the QA Plan scope to cover interdisciplinary areas defined in the plant management program MD-1, such as Safety culture, Self-assessment, Human performance, Industrial Safety etc. The attachment of the QA Plan defining relationships between certain standards was also updated to provide matrix for better correlation of requirements of

  10. Characteristics quality system assurance of university programs

    Directory of Open Access Journals (Sweden)

    Lucian Ion Medar

    2011-03-01

    Full Text Available Quality assurance program of study requires time, dedication, effort, innovative thinking and creativity. Competitive research programs monitored by quality assurance system to create the desired results on the relationship between learning and teaching methods and assessment.

  11. Introduction to quality assurance

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    In today's interpretation 'quality assurance' means 'good management'. Quality assurance has to cover all phases of a work, but all quality assurance measures must be adapted to the relevance and complexity of the actual task. Examples are given for the preparation of quality classes, the organization of quality assurance during design and manufacturing and for auditing. Finally, efficiency and limits of quality assurance systems are described. (orig.)

  12. Quality assurance in the manufacture of pressure components

    International Nuclear Information System (INIS)

    Knoedler, D.

    1979-01-01

    New regulations for nuclear power plants emphasize more quality assurance than it was the case in the past. Quality assurance is a management tool. During erection the quality assurance measures of the manufacturer, the main contractor and the required quality and the reliability of the proof of quality. The qualification of processes, equipment and personnel is a significant measure of quality assurance. The proof for quality assurance to be effective needs not only system-oriented audits, but also product audits aimed at quality characteristics of the product itself. The existing problems of examination techniques not optimized according to latest experience and of the large volume of documetation will persist in case the existing regulations are not adjusted according to the results of relevant studies. Furthermore the effectiveness of quality assurance is too often hampered by vague definitions of the safety objectives. (orig.) [de

  13. Revitalizing quality assurance

    International Nuclear Information System (INIS)

    Hawkins, F.C.

    1998-01-01

    The image of someone inspecting or auditing often comes to mind when people hear the term quality assurance. Although partially correct, this image is not the complete picture. The person doing the inspecting or auditing is probably part of a traditional quality assurance organization, but that organization is only one aspect of a properly conceived and effectively implemented quality assurance system whose goal is improved facility safety and reliability. This paper introduces the underlying philosophies and basic concepts of the International Atomic Energy Agency's new quality assurance initiative that began in 1991 as part of a broad Agency-wide program to enhance nuclear safety. The first product of that initiative was publication in 1996 of a new Quality Assurance Code 50-C/SG-Q and fourteen related Safety Guides. This new suite of documents provide the technical and philosophical foundation upon which Member States can base their quality assurance programs. (author)

  14. Software Quality Assurance Metrics

    Science.gov (United States)

    McRae, Kalindra A.

    2004-01-01

    Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.

  15. A Functional Model of Quality Assurance for Psychiatric Hospitals and Corresponding Staffing Requirements.

    Science.gov (United States)

    Kamis-Gould, Edna; And Others

    1991-01-01

    A model for quality assurance (QA) in psychiatric hospitals is described. Its functions (general QA, utilization review, clinical records, evaluation, management information systems, risk management, and infection control), subfunctions, and corresponding staffing requirements are reviewed. This model was designed to foster standardization in QA…

  16. The Groundwater Performance Assessment Project Quality Assurance Plan

    International Nuclear Information System (INIS)

    Luttrell, Stuart P.

    2006-01-01

    U.S. Department of Energy (DOE) has monitored groundwater on the Hanford Site since the 1940s to help determine what chemical and radiological contaminants have made their way into the groundwater. As regulatory requirements for monitoring increased in the 1980s, there began to be some overlap between various programs. DOE established the Groundwater Performance Assessment Project (groundwater project) in 1996 to ensure protection of the public and the environment while improving the efficiency of monitoring activities. The groundwater project is designed to support all groundwater monitoring needs at the site, eliminate redundant sampling and analysis, and establish a cost-effective hierarchy for groundwater monitoring activities. This document provides the quality assurance guidelines that will be followed by the groundwater project. This QA Plan is based on the QA requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--General Provisions/Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory's Standards-Based Management System. In addition, the groundwater project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The groundwater project has determined that the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan

  17. Quality assurance in tube manufacture

    International Nuclear Information System (INIS)

    Depken, H.

    1976-01-01

    Reliability in service essential for many high-technology products fabricated today. This is particularly the case within the nuclear industry. Here defective materials or components may have diastrous consequences to the safety of human beings and the environment. A new concept - Quality Assurance - originates from this industry. The concept implies that all contractors, fabricators and material manufactures involved must prove that the quality control system used, fulfits particular requirements at all manufacturing, inspection and testing stages. These requirement are laid down in two standards issued by the U.S. Atomic Energy Commission and the American Society of Mechanical Engineers. These standards are discussed in the paper. As a manufacturer of steel products for nuclear applications Sandvik has been forced to establish a quality assurance system according to these principles. The Sandvik approach is briefly described with regard to organisation and other major quality assurance activities. Further the education and training of operators and technicians is touched upon. Finally some viewpoints regarding audits performed by customers of steel manufacturers are expressed. (author)

  18. Regulatory viewpoint on nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    Tripp, L.E.

    1976-01-01

    Considerations of the importance of fuel quality and performance to nuclear safety, ''as low reasonably achievable'' release of radioactive materials in reactor effluents, and past fuel performance problems demonstrate the need for strong regulatory input, review and inspection of nuclear fuel quality assurance programs at all levels. Such a regulatory program is being applied in the United States of America by the US Nuclear Regulatory Commission. Quality assurance requirements are contained within government regulations. Guidance on acceptable methods of implementing portions of the quality assurance program is contained within Regulatory Guides and other NRC documents. Fuel supplier quality assurance program descriptions are reviewed as a part of the reactor licensing process. Inspections of reactor licensee control of their fuel vendors as well as direct inspections of fuel vendor quality assurance programs are conducted on a regularly scheduled basis. (author)

  19. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Eymess, K.J.; Haas, R.; Wellnitz, G.

    1980-01-01

    Quality Assurance for Nuclear Power Plants under consideration of pipe assembling. Flow of Quality Requirements during: - Desing - Construction - Procurement - Prefabrication - Site. Organizational Requirements and Measurements during Erection: - Incoming Control - Material Storage - Surveillance of Tools - Weld Surveillance - Nondestructive Testing - Cleaning - Final Documentation. Qualification and Training of QA Personnel. (orig.)

  20. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-02-01

    The Topical Report presented establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of the report

  1. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-06-01

    This topical report establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of this report

  2. Management control and quality assurance during plant operation

    International Nuclear Information System (INIS)

    Modemann, G.; Ettemeyer, R.; Stephan, W.

    1980-01-01

    The present paper deals with basic aspects of quality assurance for owners of nuclear power plants, with quality assurance for plant operation and with consequences from KTA regulatory requirements. (RW)

  3. Quality assurance for packaging of radioactive and hazardous materials

    International Nuclear Information System (INIS)

    Gustafson, L.D.

    1986-01-01

    The Department of Energy (DOE) has required for many years that quality assurance programs be established and implemented for the packaging of radioactive and hazardous materials. This paper identifies various requirement principles and related actions involved in establishing effective quality assurance for packaging of radioactive and hazardous materials. A primary purpose of these quality assurance program activities is to provide assurance that the packaging and transportation of hazardous materials, which includes radioactive and fissile materials, are in conformance with appropriate governmental regulations. Applicable regulations include those issued by the Nuclear Regulatory Commission (NRC), the Department of Transportation (DOT), and the Environmental Protection Agency (EPA). DOE Order 5700.6A establishes that quality assurance requirements are to be applied in accordance with national consensus standards where suitable ones are available. In the nuclear area, ANSI/ASME NQA-1 is the preferred standard

  4. Implementation guide for Hanford Analytical Services Quality Assurance Plan

    International Nuclear Information System (INIS)

    1994-09-01

    This implementation guide for the Hanford Analytical Services Quality Assurance Plan (HASQAP) was developed by the US Department of Energy, Richland Operations Office (RL) Waste Management Division, Analytical Services Branch. This plan formally presents RL's direction for Hanford Sitewide implementation of the HASQAP. The HASQAP establishes a uniform standard for quality requirements to meet US Department of Energy Order 5700.6C, Quality Assurance (10 CFR 830.120, ''Quality Assurance Requirements''), and is intended to satisfy the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) requirements for ''Guidance on Preparation of Laboratory Quality Assurance Plans''. The quality assurance criteria specified in the HASQAP shall serve as a baseline for implementing quality management systems for the laboratories that provide analytical services, for data requesters and users, and for oversight organizations that monitor the data-generation process. Affected organizations shall implement the HASQAP requirements that are applicable to their work scope. Full implementation of the HASQAP is scheduled to occur by August 1995. RL will work with the US Environmental Protection Agency (EPA) and Washington State Department of Ecology (Ecology) to have the HASQAP document incorporated into Appendix F of the Tri-Party Agreement by early Fiscal Year 1996

  5. Quality assurance in ionizing radiation application

    International Nuclear Information System (INIS)

    Rastkhah; Nasser.

    1995-01-01

    Quality assurance is a mean for controlling all the activities within an organization which affect the quality of the product or service. A series of international standards have been prepared which incorporate the accumulated knowledge and provide guidance on what activities within an organization should be controlled. A proposal on a quality assurance system to be implemented in ionizing radiation application centers is the primary concern of Atomic Energy Organization of Iran is represented. The Objectives were identification of quality related problems ;Comply with national and international requirements ;Controlling all activities within an organization which affects the quality and assurance of maintaining the quality within organization. In performing protection measures, risk, cost, benefit consideration, cause of problems and the classic solution are summarized in four chapters

  6. Quality assurance measures in interventional radiology

    International Nuclear Information System (INIS)

    Heuser, L.

    1999-01-01

    The quality assurance of treatment measures is legally required but as yet not generally established in practice. For interventional radiology, the introduction of quality assurance for PTA of arteries of the lower limbs is planned for January 1999. It is reasonable to subject at least the most important and/or most frequently performed interventions to quality management. In the present article, the term quality in the management of diseases is defined and the system of total quality management discussed at the levels structure, process, and results. For its application, parameters of quality measurement in the form of standards, criteria, and characteristic values are necessary and must be laid down by a team of experts on the basis of subjective experience and/or results in the literature. Practical quality assurance takes place not only within a clinic but also externally by comparison with other centers. Data collection and evaluation requires high-performance software that will be continuously improved, expanded, and adapted to current needs during regular meetings between the various users. (orig.) [de

  7. Multinational Quality Assurance

    Science.gov (United States)

    Kinser, Kevin

    2011-01-01

    Multinational colleges and universities pose numerous challenges to the traditional models of quality assurance that are designed to validate domestic higher education. When institutions cross international borders, at least two quality assurance protocols are involved. To guard against fraud and abuse, quality assurance in the host country is…

  8. Operational excellence (six sigma) philosophy: Application to software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, M.

    1997-11-01

    This report contains viewgraphs on operational excellence philosophy of six sigma applied to software quality assurance. This report outlines the following: goal of six sigma; six sigma tools; manufacturing vs administrative processes; Software quality assurance document inspections; map software quality assurance requirements document; failure mode effects analysis for requirements document; measuring the right response variables; and questions.

  9. Quality assurance of nuclear energy

    International Nuclear Information System (INIS)

    1994-12-01

    It consists of 14 chapters, which are outline of quality assurance of nuclear energy, standard of quality assurance, business quality assurance, design quality assurance, purchase quality assurance, production quality assurance, a test warranty operation warranty, maintenance warranty, manufacture of nuclear power fuel warranty, computer software warranty, research and development warranty and quality audit.

  10. Quality Assurance Program Plan for the Waste Sampling and Characterization Facility

    International Nuclear Information System (INIS)

    Grabbe, R.R.

    1995-01-01

    The objective of this Quality Assurance Plan is to provide quality assurance (QA) guidance, implementation of regulatory QA requirements, and quality control (QC) specifications for analytical service. This document follows the Department of Energy (DOE)-issued Hanford Analytical Services Quality Assurance Plan (HASQAP) and additional federal [10 US Code of Federal Regulations (CFR) 830.120] QA requirements that HASQAP does not cover. This document describes how the laboratory implements QA requirements to meet the federal or state requirements, provides what are the default QC specifications, and/or identifies the procedural information that governs how the laboratory operates. In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. This document also covers QA elements that are required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAPPs), (QAMS-004), and Interim Guidelines and Specifications for Preparing Quality Assurance Product Plans (QAMS-005) from the Environmental Protection Agency (EPA). A QA Index is provided in the Appendix A

  11. An operational health physics quality assurance program

    International Nuclear Information System (INIS)

    Costigan, S.A.; McAtee, J.L. III; Somers, W.M.; Huchton, R.L.

    1996-01-01

    DOE Order 5700.6C, Quality Assurance, stipulates QA requirements for all DOE activities. This order is now codified as 10CFR830.120, Nuclear Safety Management, Quality Assurance Requirements, which is applicable to DOE nuclear facilities. A Quality Assurance Management Plan (QAMP) was developed by the Health Physics Operations Group (ESH-1) at Los Alamos National Laboratory (LANL). The goal of the ESH-1 QAMP is to ensure that operational radiation protection activities meet the criteria outlined in DOE Order 5700.6C, DOE-ER-STD-6001-92 and 10CFR830.120. The ten required elements are QA Program, Personal Training and Qualifications, Quality Improvement, Documents and Records, Work Processes, Design, Procurement, Inspection and Acceptance Testing, Management Assessment and Independent Assessment. The QAMP has been useful for the development of QAMPs at nuclear facilities and has helped ensure uniformity of institutional requirements where Health Physics services are deployed to facilities. To implement a subset of QAMP requirements, a Quality Assurance Self-Evaluation Program (QASE) was established. This program provides a novel self-audit mechanism for the formal identification and correction of non-conforming items related to Operational Health Physics. Additionally, the QASE is a useful management tool for Radiological Control Technician Supervisors and staff and provides a tracking mechanism for ongoing problem areas. Data have been Collected for two calendar years on a number of concerns that fall into four general categories: radiological posting and labeling, instrumentation, monitoring requirements, and radiological documents/records

  12. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  13. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  14. Quality Assurance In Radioactivity Measurements

    International Nuclear Information System (INIS)

    Riekstina, D.; Veveris, O.; Smilskalne, G.

    2007-01-01

    The credibility of obtained results is ensured by the quality assurance and control. The main requisitions involved in the quality assurance of the laboratory according to the requirements of LVS EN ISO/IEC 17025:2005 are: 1) the use of calibrated equipment only; 2) the regular and long-time use of reference materials in the control of equipment; 3) the estimation of uncertainty sources and determination of uncertainties within the given interval of credibility; 4) the validation and verification. The very important requirement is regular participation in the interlaboratory intercomparison exercises that makes it possible to estimate and find possible error sources and carry out the corrective actions. The measurements of the radioactivity of Cs-137, Co-60, H-3, the natural radioactive nuclides as well as other radionuclides in different environmental (soil, precipitation, different types of water, needles, et al.) samples, and in various radioactive polluted objects are carried out in the Laboratory of Radiation physics. The quality assurance system was implemented in our laboratory in 2000. Since 1999 laboratory is regular participant in the interlaboratory intercomparison exercises, organized by the RISO National Laboratory (Denmark) and IAEA (Vienna). The paper shows the laboratory's system of quality assurance and its implementation. We have the internal quality audit program that takes into account the requirements of LVS EN ISO/IEC 17025: 2005, but the main attention is paid to the intercomparison of the results of analyses of laboratories, their evaluation and interpretation. Only credible and justified results can be the basis for further use in any field, thus making it possible to make legitimate decisions. (Authors)

  15. Nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    1976-01-01

    Full text: Quality assurance is used extensively in the design, construction and operation of nuclear power plants. This methodology is applied to all activities affecting the quality of a nuclear power plant in order to obtain confidence that an item or a facility will perform satisfactorily in service. Although the achievement of quality is the responsibility of all parties participating in a nuclear power project, establishment and implementation of the quality assurance programme for the whole plant is a main responsibility of the plant owner. For the plant owner, the main concern is to achieve control over the quality of purchased products or services through contractual arrangements with the vendors. In the case of purchase of nuclear fuel, the application of quality assurance might be faced with several difficulties because of the lack of standardization in nuclear fuel and the proprietary information of the fuel manufacturers on fuel design specifications and fuel manufacturing procedures. The problems of quality assurance for purchase of nuclear fuel were discussed in detail during the seminar. Due to the lack of generally acceptable standards, the successful application of the quality assurance concept to the procurement of fuel depends on how much information can be provided by the fuel manufacturer to the utility which is purchasing fuel, and in what form and how early this information can be provided. The extent of information transfer is basically set out in the individual vendor-utility contracts, with some indirect influence from the requirements of regulatory bodies. Any conflict that exists appears to come from utilities which desire more extensive control over the product they are buying. There is a reluctance on the part of vendors to permit close insight of the purchasers into their design and manufacturing procedures, but there nevertheless seems to be an increasing trend towards release of more information to the purchasers. It appears that

  16. Hanford Tanks Initiative quality assurance implementation plan

    International Nuclear Information System (INIS)

    Huston, J.J.

    1998-01-01

    Hanford Tanks Initiative (HTI) Quality Assurance Implementation Plan for Nuclear Facilities defines the controls for the products and activities developed by HTI. Project Hanford Management Contract (PHMC) Quality Assurance Program Description (QAPD)(HNF-PRO599) is the document that defines the quality requirements for Nuclear Facilities. The QAPD provides direction for compliance to 10 CFR 830.120 Nuclear Safety Management, Quality Assurance Requirements. Hanford Tanks Initiative (HTI) is a five-year activity resulting from the technical and financial partnership of the US Department of Energy's Office of Waste Management (EM-30), and Office of Science and Technology Development (EM-50). HTI will develop and demonstrate technologies and processes for characterization and retrieval of single shell tank waste. Activities and products associated with HTI consist of engineering, construction, procurement, closure, retrieval, characterization, and safety and licensing

  17. Quality Assurance of Quality Assurance Agencies from an Asian Perspective: Regulation, Autonomy and Accountability

    Science.gov (United States)

    Hou, Angela Yung-Chi; Ince, Martin; Tsai, Sandy; Chiang, Chung Lin

    2015-01-01

    As quality guardians of higher education, quality assurance agencies are required to guarantee the credibility of the review process and to ensure the objectivity and transparency of their decisions and recommendations. These agencies are therefore expected to use a range of internal and external approaches to prove the quality of their review…

  18. quality assurance systems in nuclear fuel procurement and manufacturing

    International Nuclear Information System (INIS)

    Can, S.

    1997-01-01

    Quality is the totality of features and characteristics of a product or service that bear on its ability to satisfy stated or implied needs. Quality control is activities and techniques used to fulfill the requirements of quality. Quality assurance is a system and its main components are requirements. QA program, organization and responsibilities, design and verification, material and its control, manufacturing and process control, inspections, audits and documents: manuals, specifications, instructions. Quality assurance systems are largely based on ISO 9000 series of the International Standards Organization. ISO 9000 series has been adopted and published by Turkish Standards Institute as TS-ISO 9000. International Atomic Energy Agency also published a guide (50-SG-QA11) ''Quality Assurance in the Procurement, Design and Manufacture of Nuclear Fuel Assemblies'' in the safety guide series. In this study the role of quality control in quality assurance systems, inspection and test plans and acceptance and nonconformance quality levels will be explained in relation to nuclear fuel production. Examples of applications in quality assurance systems based on ISO 9000 will be given

  19. The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    Fix, Anne

    2007-01-01

    The U.S. Department of Energy (DOE) has conducted interim groundwater remedial activities on the Hanford Site since the mid-1990s for several groundwater contamination plumes. DOE established the Columbia River Protection Supplemental Technologies Project (Technologies Project) in 2006 to evaluate alternative treatment technologies. The objectives for the technology project are as follows: develop a 300 Area polyphosphate treatability test to immobilize uranium, design and test infiltration of a phosphate/apatite technology for Sr-90 at 100-N, perform carbon tetrachloride and chloroform attenuation parameter studies, perform vadose zone chromium characterization and geochemistry studies, perform in situ biostimulation of chromium studies for a reducing barrier at 100-D, and perform a treatability test for phytoremediation for Sr-90 at 100-N. This document provides the quality assurance guidelines that will be followed by the Technologies Project. This Quality Assurance Project Plan is based on the quality assurance requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory?s Standards-Based Management System. In addition, the technology project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan.

  20. The quality assurance practice in Spain

    International Nuclear Information System (INIS)

    Mugica, A.P.

    1980-01-01

    Even when the basic requirements for a Quality Assurance Program are delineated in documents such as the Code of Federal Regulations or Standards like ANSI N 45. 2, the way in which these requirements are put into practice is very dependent on the organization to which they are applied. So, in order to approach accurately the Quality Assurance practice and experience in Spain, the legal and industrial scenario must be considered. We are trying to present an outlook of the Spanish Energy Plan, Regulations and Nuclear Industry. (orig.)

  1. Application of Quality Assurance to MCandA systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Quality Assurance has been applied to the MCandA function within the Department of Energy's Savannah River Operations Office. It was applied to both the activities used to operate the MCandA Branch and the activities used by the Branch to overview the MCandA function of DOE/SR's contractor. In this paper, the principles of quality assurance are reviewed and their application at DOE/SR is discussed. In addition, quality assurance can be applied to the broader MCandA functions required of those facilities producing, using, and handling nuclear materials. Application of quality assurance to those broader functions is also discussed

  2. Laboratory quality assurance

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1977-01-01

    The elements (principles) of quality assurance can be applied to the operation of the analytical chemistry laboratory to provide an effective tool for indicating the competence of the laboratory and for helping to upgrade competence if necessary. When used, those elements establish the planned and systematic actions necessary to provide adequate confidence in each analytical result reported by the laboratory (the definition of laboratory quality assurance). The elements, as used at the Hanford Engineering Development Laboratory (HEDL), are discussed and they are qualification of analysts, written methods, sample receiving and storage, quality control, audit, and documentation. To establish a laboratory quality assurance program, a laboratory QA program plan is prepared to specify how the elements are to be implemented into laboratory operation. Benefits that can be obtained from using laboratory quality assurance are given. Experience at HEDL has shown that laboratory quality assurance is not a burden, but it is a useful and valuable tool for the analytical chemistry laboratory

  3. Quality assurance plan, Westinghouse Water Reactor Divisions

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    The Quality Assurance Program used by Westinghouse Nuclear Energy Systems Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements.

  4. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    Science.gov (United States)

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  5. Study on quality assurance for high-level radioactive waste disposal project (2). Quality assurance system for the site characterization phase in the Yucca Mountain Project

    International Nuclear Information System (INIS)

    Takada, Susumu

    2006-01-01

    The objective of this report is to assist related organizations in the development of quality assurance systems for a high-level radioactive waste disposal system. This report presents detail information with which related organizations can begin the development of quality assurance systems at an initial phase of repository development for a high-level radioactive waste disposal program, including data qualification, model validation, systems and facilities for quality assurance (e.g., technical data management system, sample management facility, etc.), and QA program applicability (items and activities). These descriptions are based on information in QA program for the Yucca Mountain Project (YMP), such as the U.S. Department of Energy (DOE) Quality Assurance Requirements and Description (QARD), DOE/RW-0333P, quality implementing procedures, and reports implemented by the procedures. Additionally, this report includes some brief recommendations for developing of quality assurance systems, such as establishment of quality assurance requirements, measures for establishment of QA system. (author)

  6. Legacy Management CERCLA Sites. Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Riddle, Donna L.

    2007-05-03

    S.M. Stoller Corporation is the contractor for the Technical Assistance Contract (TAC) for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) operations. Stoller employs a management system that applies to all programs, projects, and business management systems funded through DOE-LM task orders. The management system incorporates the philosophy, policies, and requirements of health and safety, environmental compliance, and quality assurance (QA) in all aspects of project planning and implementation. Health and safety requirements are documented in the Health and Safety Manual (STO 2), the Radiological Control Manual (STO 3), the Integrated Safety Management System Description (STO 10), and the Drilling Health and Safety Requirements (STO 14). Environmental compliance policy and requirements are documented in the Environmental Management Program Implementation Manual (STO 11). The QA Program is documented in the Quality Assurance Manual (STO 1). The QA Manual (STO 1) implements the specific requirements and philosophy of DOE Order 414.1C, Quality Assurance. This manual also includes the requirements of other standards that are regularly imposed by customers, regulators, or other DOE orders. Title 10 Code of Federal Regulations Part 830, “Quality Assurance Requirements,” ANSI/ASQC E4-2004, “Quality Systems for Environmental Data and Technology Programs – Requirements with Guidance for Use,” and ISO 14001-2004, “Environmental Management Systems,” have been included. These standards are similar in content. The intent of the QA Manual (STO 1) is to provide a QA management system that incorporates the requirements and philosophy of DOE and other customers within the QA Manual. Criterion 1, “Quality Assurance Program,” identifies the fundamental requirements for establishing and implementing the QA management system; QA Instruction (QAI) 1.1, “QA Program Implementation,” identifies the TAC organizations that have responsibility for

  7. Legacy Management CERCLA Sites. Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    2007-01-01

    S.M. Stoller Corporation is the contractor for the Technical Assistance Contract (TAC) for the U.S. Department of Energy (DOE) Office of Legacy Management (LM) operations. Stoller employs a management system that applies to all programs, projects, and business management systems funded through DOE-LM task orders. The management system incorporates the philosophy, policies, and requirements of health and safety, environmental compliance, and quality assurance (QA) in all aspects of project planning and implementation. Health and safety requirements are documented in the Health and Safety Manual (STO 2), the Radiological Control Manual (STO 3), the Integrated Safety Management System Description (STO 10), and the Drilling Health and Safety Requirements (STO 14). Environmental compliance policy and requirements are documented in the Environmental Management Program Implementation Manual (STO 11). The QA Program is documented in the Quality Assurance Manual (STO 1). The QA Manual (STO 1) implements the specific requirements and philosophy of DOE Order 414.1C, Quality Assurance. This manual also includes the requirements of other standards that are regularly imposed by customers, regulators, or other DOE orders. Title 10 Code of Federal Regulations Part 830, 'Quality Assurance Requirements', ANSI/ASQC E4-2004, 'Quality Systems for Environmental Data and Technology Programs - Requirements with Guidance for Use', and ISO 14001-2004, 'Environmental Management Systems', have been included. These standards are similar in content. The intent of the QA Manual (STO 1) is to provide a QA management system that incorporates the requirements and philosophy of DOE and other customers within the QA Manual. Criterion 1, 'Quality Assurance Program', identifies the fundamental requirements for establishing and implementing the QA management system; QA Instruction (QAI) 1.1, 'QA Program Implementation', identifies the TAC organizations that have responsibility for implementing the QA

  8. IAEA code and safety guides on quality assurance

    International Nuclear Information System (INIS)

    Raisic, N.

    1980-01-01

    In the framework of its programme in safety standards development, the IAEA has recently published a Code of Practice on Quality Assurance for Safety in Nuclear Power Plants. The Code establishes minimum requirements for quality assurance which Member States should use in the context of their own nuclear safety requirements. A series of 10 Safety Guides which describe acceptable methods of implementing the requirements of specific sections of the Code are in preparation. (orig.)

  9. Quality assurance in medical laboratories

    International Nuclear Information System (INIS)

    Boroviczeny, K.G. von; Merten, R.; Merten, U.P.

    1987-01-01

    The book presents a comprehensive and specified survey of the quality assurance measures and methods applied in medical laboratories in the pre-analytical phase and in the analytical and post-analytical phases. It also gives information on computer-aided procedures, cost-benefit analyses in this field, and on official requirements and standards in the fields of clinical chemistry, hematology, immunology and microbiology, and equipment testing and inspection. One chapter of the book particularly deals with quality assurance for radioimmunological in-vitro analyses. With 112 figs., 337 tabs [de

  10. Quality assurance program requirements (design and construction). Task RS 002-5. Revision 3

    International Nuclear Information System (INIS)

    1985-08-01

    This regulatory guide describes a method acceptable to the NRC staff for complying with regard to establishing and implementing the requisite quality assurance program for the design and construction of nuclear power plants. Guidance for the establishment and execution of quality assurance programs during operation and decommissioning of nuclear power plants have been or will be addressed in separate regulatory guides. Similarly, quality assurance provisions concerning fuel cycle facilities have been or will be addressed in separate regulatory guides

  11. Quality assurance in radiation processing

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The growth of the radiation processing industries in Malaysia has presented the SSDL-MINT a new set of parameter for the Quality Assurance (QA) programs. The large massive doses of radiation required for commercial application of sterilization, cross-linking etc needs measurement method outside the scope of familiar radiation detection instruments. This requires establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to an international radiation standard. The benefit of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good QA is presented. (Author)

  12. Quality assurance - the key to the future

    Energy Technology Data Exchange (ETDEWEB)

    Rix, C [British Coal Corporation, London (UK)

    1992-05-01

    Quality assurance seeks to achieve diligence and attention to detail, which can have substantial effects including reduced costs and improved performance, as well as greater customer satisfaction. British Coal has a policy of quality assurance to BS5750 at all collieries and despatch points, to help maintain its competitive position, to respond to customer requirements, and to continue the drive for reduced costs. A pilot exercise was undertaken at Maltby and Kellingley collieries, and at Oxcroft and Gwaun-cae-Gurwen opencast despatch points, in order to gain sufficient experience to allow rapid implementation of quality assurance at all sites.

  13. Quality assurance requirements in the testing of packages to be used for safe transportation of RAM

    International Nuclear Information System (INIS)

    Vieru, Gheorghe; Nistor, Viorica; Mihaiu, Ramona

    2010-01-01

    The quality of the Type A, B or C packages used for transport and storage of Radioactive Material (RAM) has to be proved by performing qualification tests in accordance with the Transport Regulations, within the Reliability and Testing Laboratory, Institute for Nuclear Research (INR) Pitesti, where has designed and developed a new Romanian Testing Facility. The qualifications testing are performed under a strict quality assurance programme based on the specific procedures prior approved by the Romanian Nuclear Regulatory Body CNCAN (National Commission for Nuclear Activity Control). This paper describe the quality assurance programme in accordance with the quality management system developed in order to meet the requirements provided by the national regulations as well as to the requirements of the IAEA's safety standard TS-R-1 related to testing of packages to be used for transport of RAM and also provides an overview of the new Romanian Testing Facilities for RAM Packages, developed by the INR's Reliability and Testing Laboratory within an Excellence Scientific Contract. (authors)

  14. Quality assurance

    International Nuclear Information System (INIS)

    Cante; Feger; Genevray; Hennion; Moneyron; Monneyron; Normand; Rastoin; Silberstein; Vaujour.

    1976-01-01

    The general principles of quality assurance and their applications within the French industrial and commercial regulations are presented. The conditions for the practical application of quality assurance to the different stages of the life of a nuclear power station (design, development, operation) are considered and a special mention is made of nuclear fuels and liquid sodium cooled reactors [fr

  15. Requirements for, and training and certification of, quality assurance technicians for nuclear power plants

    International Nuclear Information System (INIS)

    Saiz, A.; Mir, A.; Serrano, J.

    1982-01-01

    The paper examines the requirements for, and training and certification of, technicians working in a quality assurance department at periods when the site, the main supplier and the engineering firm are being selected for construction, commissioning and operation of a light-water nuclear power plant with an output of approximately 1000 MW(e). In determining the system to be applied for the present work, account is taken of the special fields of engineering, supply, commissioning and operation. To this end, an analysis is made of the necessary organization, pointing out the number of technicians in each of the phases mentioned, and the necessary experience and knowledge required for discharging the functions indicated and for obtaining the appropriate certification. The second generation of Spanish nuclear power stations - about 7500MW(e) - demonstrated the need for quality assurance technicians. The Spanish Atomic Forum, a member of Foratom, is the first Spanish body to deal with the problem of training of such technicians at the national level through holding of seminars. This led to the appearance (in April 1974) of the first publication in Spanish on these techniques, a document which is still being used for teaching purposes. Later, it was the university and the professional associations which, with the support of the State Administration, undertook to provide this instruction. The paper also analyses Spanish experience in the teaching of quality assurance techniques during the period 1975-80, describing the programmes and contents of the courses

  16. QAM: PROPOSED MODEL FOR QUALITY ASSURANCE IN CBSS

    Directory of Open Access Journals (Sweden)

    Latika Kharb

    2015-08-01

    Full Text Available Component-based software engineering (CBSE / Component-Based Development (CBD lays emphasis on decomposition of the engineered systems into functional or logical components with well-defined interfaces used for communication across the components. Component-based software development approach is based on the idea to develop software systems by selecting appropriate off-the-shelf components and then to assemble them with a well-defined software architecture. Because the new software development paradigm is much different from the traditional approach, quality assurance for component-based software development is a new topic in the software engineering research community. Because component-based software systems are developed on an underlying process different from that of the traditional software, their quality assurance model should address both the process of components and the process of the overall system. Quality assurance for component-based software systems during the life cycle is used to analyze the components for achievement of high quality component-based software systems. Although some Quality assurance techniques and component based approach to software engineering have been studied, there is still no clear and well-defined standard or guidelines for component-based software systems. Therefore, identification of the quality assurance characteristics, quality assurance models, quality assurance tools and quality assurance metrics, are under urgent need. As a major contribution in this paper, I have proposed QAM: Quality Assurance Model for component-based software development, which covers component requirement analysis, component development, component certification, component architecture design, integration, testing, and maintenance.

  17. Quality assurance program plan for SNF characterization support project

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides information on how the Quality Assurance Program is implemented for the Spent Nuclear Fuel Characterization Support Project. This QAPP has been developed specifically for the Spent Nuclear Fuel Characterization Support Project, per Letter of Instruction (LOI) from Duke Engineering and Services Company, letter No. DESH-9655870, dated Nov. 22, 1996. It applies to those items and tasks which affect the completion of activities identified in the work breakdown structure of the Project Management Plan (PMP) and LOI. These activities include installation of sectioning equipment and furnace, surface and subsurface examinations, sectioning for metallography, and element drying and conditioning testing, as well as project related operations within the 327 facility as it relates to the specific activities of this project. General facility activities are covered in other appropriate QA-PPS. In addition, this QAPP supports the related quality assurance activities addressed in CM-2-14, Hazardous Material Packaging and Shipping,1261 and HSRCM-1, Hanford Site Radiological Control Manual. The 327 Building is currently transitioning from being a Pacific Northwest National Laboratory (PNNL) managed facility to a Babcock and Wilcox Hanford Company (BVMC) managed facility. During this transition process existing procedures and documents will be utilized until replaced by BVMC procedures and documents. These documents conform to the requirements found in PNL-MA-70, Quality Assurance Manual and PNL-MA-8 1, Hazardous Materials Shipping Manual. The Quality Assurance Program Index (QAPI) contained in Table 1 provides a matrix which shows how project activities relate to IO CFR 830.120 and 5700.6C criteria. Quality Assurance program requirements will be addressed separate from the requirements specified in this document. Other Hanford Site organizations/companies may be utilized in support of this project and the subject organizations are

  18. LASL computerized quality assurance record-keeping system for analytical chemistry

    International Nuclear Information System (INIS)

    Dahlby, J.W.; Phillips, J.R.

    1976-06-01

    Research programs requiring quality assurance surveillance, certification procedures, and associated record keeping have increased markedly at the Los Alamos Scientific Laboratory. A computer-based system, accessible through time-sharing terminals, performs many routine operations, including continued records updating for equipment calibration, personnel certification, quality assurance procedure listings, and controlled-document distribution lists. The system described has operated successfully for more than a year, resulting in a significant savings in man-hours required to keep quality assurance records

  19. Quality assurance manual for the development of digital systems

    International Nuclear Information System (INIS)

    Lee, Cheol Kwon; Kwon, Kee Choon; You, Young Eun; Kim, Kwan Hyun; Park, Jung Woo; Park, Chan Seok

    2001-12-01

    A digital safety system is being developed by three companies under the Korea Nuclear I and C System R and D Program. This Quality Assurance Manual (QAM) is written to ensure the safety and reliability of the system and to meet the regulatory requirements associated with quality assurance. This QAM describes eighteen elements of quality assurance criteria required for the development of the system, which are coincident with the criteria specified in Nuclear Energy Laws and Enforcement Regulations of Nuclear Energy Laws and 10CFR50 Appendix B. This QAM is submitted to the regulatory body with other documents related to the quality assurance activities performed during the system development. And its safety, validity and fulfillment are reviewed and audited in the review process of topical report of the digital safety system

  20. Quality assurance of metabolomics.

    Science.gov (United States)

    Bouhifd, Mounir; Beger, Richard; Flynn, Thomas; Guo, Lining; Harris, Georgina; Hogberg, Helena; Kaddurah-Daouk, Rima; Kamp, Hennicke; Kleensang, Andre; Maertens, Alexandra; Odwin-DaCosta, Shelly; Pamies, David; Robertson, Donald; Smirnova, Lena; Sun, Jinchun; Zhao, Liang; Hartung, Thomas

    2015-01-01

    Metabolomics promises a holistic phenotypic characterization of biological responses to toxicants. This technology is based on advanced chemical analytical tools with reasonable throughput, including mass-spectroscopy and NMR. Quality assurance, however - from experimental design, sample preparation, metabolite identification, to bioinformatics data-mining - is urgently needed to assure both quality of metabolomics data and reproducibility of biological models. In contrast to microarray-based transcriptomics, where consensus on quality assurance and reporting standards has been fostered over the last two decades, quality assurance of metabolomics is only now emerging. Regulatory use in safety sciences, and even proper scientific use of these technologies, demand quality assurance. In an effort to promote this discussion, an expert workshop discussed the quality assurance needs of metabolomics. The goals for this workshop were 1) to consider the challenges associated with metabolomics as an emerging science, with an emphasis on its application in toxicology and 2) to identify the key issues to be addressed in order to establish and implement quality assurance procedures in metabolomics-based toxicology. Consensus has still to be achieved regarding best practices to make sure sound, useful, and relevant information is derived from these new tools.

  1. System management and quality assurance

    International Nuclear Information System (INIS)

    Sastry, A.M.

    1989-01-01

    This paper describes the principles of system management and shows the relationship to quality assurance. It discusses the need for balanced attention to all the project management controls required for project success

  2. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site

  3. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site.

  4. References on EPA Quality Assurance Project Plans

    Science.gov (United States)

    Provides requirements for the conduct of quality management practices, including quality assurance (QA) and quality control (QC) activities, for all environmental data collection and environmental technology programs performed by or for this Agency.

  5. The challenge of quality assurance

    International Nuclear Information System (INIS)

    Simon, R.; Krischer, W.; Price, M.S.T.

    1986-01-01

    The paper presents the aims of quality assurance in the design and production of radioactive waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organisational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. The Commission of European Communities has laid emphasis on the development of appropriate test methods in its last research and development programme. First results of the work are reviewed in the context of international progress in this field. (author)

  6. Quality assurance in NDT

    International Nuclear Information System (INIS)

    Krishnamoorthy, K.

    2010-01-01

    The importance of Nondestructive Testing (NDT) as a Quality Control/Quality Assurance tool in the industrial domain cannot be over-emphasized. With the rapid advancement in research and technology, the NDT field is becoming larger and more sophisticated day by day. Innovative research in materials science and digital technology is paving the way for more and more new methods in NDT technology. Although the NDT technology has improved over the years, the basic 'human factor' underlying the success of the NDT field remains the same. There are two major factors that influence the 'Quality Assurance in NDT'. First, knowledgeable and skilled NDT Operators are the most important factor in assuring the reliable test results. Second, the Management oversight of the NDT operations plays a major role in assuring the overall quality of NDT. Management responsibilities include the implementation of a Quality Management System (QMS) that focuses on the NDT operations and apply all the elements of Quality Assurance relevant to NDT. Whether the NDT operations are performed in-house or by a contractor, periodic Management Self-assessments should include the following question: How can the Management assess and improve the 'Quality Assurance in NDT'? This paper attempts to answer the above question. Some practical examples are provided to illustrate the potential quality incidents that could lead to costly failures, and the role of NDT Operator and the Management in preventing such quality incidents. Also, some guidelines are provided on how the Management can apply the elements of Quality Assurance to NDT in order to assess and improve the 'Quality Assurance in NDT'. (author)

  7. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  8. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  9. Computer software quality assurance

    International Nuclear Information System (INIS)

    Ives, K.A.

    1986-06-01

    The author defines some criteria for the evaluation of software quality assurance elements for applicability to the regulation of the nuclear industry. The author then analyses a number of software quality assurance (SQA) standards. The major extracted SQA elements are then discussed, and finally specific software quality assurance recommendations are made for the nuclear industry

  10. Quality assurance in siting of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2005-03-01

    This guide describes the requirements of quality assurance programme (QAP) that need to be implemented at the siting stage, by the organisation having overall responsibility for the nuclear power plant. The scope of the guide covers the quality assurance aspects related to management, performance and assessment activities during siting stage of NPPs

  11. [Quality assurance concepts in intensive care medicine].

    Science.gov (United States)

    Brinkmann, A; Braun, J P; Riessen, R; Dubb, R; Kaltwasser, A; Bingold, T M

    2015-11-01

    Intensive care medicine (ICM) is characterized by a high degree of complexity and requires intense communication and collaboration on interdisciplinary and multiprofessional levels. In order to achieve good quality of care in this environment and to prevent errors, a proactive quality and error management as well as a structured quality assurance system are essential. Since the early 1990s, German intensive care societies have developed concepts for quality management and assurance in ICM. In 2006, intensive care networks were founded in different states to support the implementation of evidence-based knowledge into clinical routine and to improve medical outcome, efficacy, and efficiency in ICM. Current instruments and concepts of quality assurance in German ICM include core intensive care data from the data registry DIVI REVERSI, quality indicators, peer review in intensive care, IQM peer review, and various certification processes. The first version of German ICM quality indicators was published in 2010 by an interdisciplinary and interprofessional expert commission. Key figures, indicators, and national benchmarks are intended to describe the quality of structures, processes, and outcomes in intensive care. Many of the quality assurance tools have proved to be useful in clinical practice, but nationwide implementation still can be improved.

  12. Quality assurance program

    International Nuclear Information System (INIS)

    Brooks, G.L.

    The concept of levels of quality assurance as applied to CANDU-type nuclear power plant components, i.e. maintaining an appropriate cost/benefit ratio, is introduced. The design process itself has quality assurance features by virtue of multi-level review. (E.C.B.)

  13. Linear accelerator quality assurance using EPIQA software

    International Nuclear Information System (INIS)

    Bozhikov, S.; Sokerov, H.; Tonev, A.; Ivanova, K.

    2012-01-01

    Unlike treatment with static fields, using a dynamic multileaf collimator (dMLC), there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. The advanced techniques require some additional commissioning and quality assurance tests. The results of standard quality assurance (QA) machine tests and commissioning tests for volume modulated arc therapy (VMAT) using electronic portal image device (EPID) and 'EPIQA' software are presented. (authors)

  14. Study on quality assurance for high-level radioactive waste disposal project

    International Nuclear Information System (INIS)

    Takada, Susumu

    2005-01-01

    The U.S. Department of Energy (DOE) has developed comparatively detailed quality assurance requirements for the high-level radioactive waste disposal systems. Quality assurance is recognized as a key issue for confidence building and smooth implementation of the HLW program in Japan, and Japan is at an initial phase of repository development. Then the quality assurance requirements at site research and site selection, site characterization, and site suitability analysis used in the Yucca Mountain project were examined in detail and comprehensive descriptions were developed using flow charts. Additionally, the applicability to the Japan high-level radioactive waste disposal project was studied. The examination and study were performed for the following QA requirements: The requirements that have the relative importance at site research and site selection, site characterization, and site suitability analysis (such as planning and performing scientific investigations, sample control, data control, model development and use, technical report review, software control, and control of the electric management of data). The requirements that have the relative importance at the whole repository phases (such as quality assurance program, document control, and control of quality assurance records). (author)

  15. Quality assurance and product quality

    International Nuclear Information System (INIS)

    Lacroix, D.; Bastiani, P. de

    2004-01-01

    The basic quality assurance requirements have to be completed by means that are oriented towards the quality of products; in COGEMA LOGISTICS our approach is based on four principles: 1) an integrated management system: Quality, health and safety, environment 2) an organization based on the responsibility of all actors, trust and transparency 3) a methodical approach to continuously improve the methods that are employed to achieve quality: -process management -corrective and preventive actions -self assessments and various surveys 4) but at the same time strong procedures for control and monitoring of all activities: -technical and quality audits (external and internal) -at source inspections -engineering activities inspections This performance-based approach is necessary to guaranty the effectiveness of the traditional formal QA means

  16. Quality Assurance for Operation of Nuclear Facilities

    International Nuclear Information System (INIS)

    Park, C. G.; Kwon, H. I.; Kim, K. H.; Oh, Y. W.; Lee, Y. G.; Ha, J. H.; Lim, N. J.

    2008-12-01

    This report describes QA activities performed within 'Quality Assurance for Nuclear facility project' and results thereof. Efforts were made to maintain and improve quality system of nuclear facilities. Varification activities whether quality system was implemented in compliance with requirements. QA department assisted KOLAS accredited testing and calibration laboratories, ISO 9001 quality system, establishment of QA programs for R and D, and carried out reviews and surveys for development of quality assurance technologies. Major items of this report are as follows : - Development and Improvement of QA Programs - QA Activities - Assessment of Effectiveness and Adequacy for QA Programs

  17. Quality assurance program plan for low-level waste at the WSCF Laboratory

    International Nuclear Information System (INIS)

    Morrison, J.A.

    1994-01-01

    The purpose of this document is to provide guidance for the implementation of the Quality Assurance Program Plan (QAPP) for the management of low-level waste at the Waste Sampling and Characterization Facility (WSCF) Laboratory Complex as required by WHC-CM-4-2, Quality Assurance Manual, which is based on Quality Assurance Program Requirements for Nuclear Facilities, NQA-1 (ASME)

  18. The Role Of Quality Assurance Program For Safety Operation Of Nuclear Installations

    International Nuclear Information System (INIS)

    Harjanto, N.T.; Purwadi, K.P.; Boru, D.S.; Farida; Suharni

    2000-01-01

    Nuclear installations expose potential hazard of radiation, therefore in their construction, operation and maintenance, it is necessary to consider safety aspect, in which the safety requirements which has been determined must be met. One of the requirements that is absolutely needed is quality assurance, which covers arrangement of quality assurance program, organization and administration of the implementation of quality assurance, and supervision. Quality Assurance program is a guideline containing quality policies and basic determination on the realization of activities that effect the quality of equipment's and items used in the operation of nuclear installations in order that the operation of nuclear installation can run safety and in accordance with their design aims and operation limits. Quality Assurance Program includes document control, design control, supply control, control of equipment s and items, operation/process control, inspection and control of equipment test, and control of nonconformance and corrections. General system of nuclear installation operation is equipped with safety and supporting systems. These systems must apply the quality assurance program that cover control of activities in the systems. In the implementation of the quality assurance program, it is necessary to establish procedures, work guidelines/instructions, and quality recording that constitutes documents of quality system 2 nd , 3 th , and 4 th level after the quality assurance program. To ensure the effectivity and to prove whether the realization of the program has been pursuant to the determined requirements, an internal audit must be conducted accordingly

  19. Quality assurance

    OpenAIRE

    Cauchi, Maurice A.M.

    1993-01-01

    The concept of quality assurance refers more specifically to the process of objectifying and clearly enunciating goals, and providing means of assessing the outcomes. In this article the author mentions four fundamental elements of quality assurance which should be applied in the medical profession in Malta. These elements should relate to professional performance, resource utilisation, risk management and patient satisfaction. The aim of the medical professionals in Malta is to provide the b...

  20. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  1. Quality Assurance Program Plan (QAPP) Waste Encapsulation and Storage Facility (WESF)

    International Nuclear Information System (INIS)

    ROBINSON, P.A.

    2000-01-01

    This Quality Assurance Plan describes how the Waste Encapsulation and Storage Facility (WESF) implements the quality assurance (QA) requirements of the Quality Assurance Program Description (QAPD) (HNF-Mp-599) for Project Hanford activities and products. This QAPP also describes the organizational structure necessary to successfully implement the program. The QAPP provides a road map of applicable Project Hanford Management System Procedures, and facility specific procedures, that may be utilized by WESF to implement the requirements of the QAPD

  2. Quality assurance and the sub-contract interface: co-operative evaluations

    International Nuclear Information System (INIS)

    Churchill, G.F.; Rippon, D.J.

    1976-01-01

    A common feature of all contemporary Quality Assurance Standards is the requirement for organisations, when carrying out purchasing activities, to select their suppliers on the basis of either a proven record or demonstrated quality capability. In particular the C.E.G.B. Standard QA42-1 Quality Assurance Programme, which the C.E.G.B. will apply to their future major projects, requires purchasers to establish supplier selection and assessment procedures using one or other of the following methods: (a) a previous continuous record of supplying identical or equivalent material to a satisfactory standard; or (b) an evaluation of the sub-contractor's quality assurance system to determine his ability to satisfy the procurement requirements. Co-operative evaluations, where there are several suppliers, are discussed. (author)

  3. 222-S laboratory quality assurance plan

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This document provides quality assurance guidelines and quality control requirements for analytical services. This document is designed on the basis of Hanford Analytical Services Quality Assurance Plan (HASQAP) technical guidelines and is used for governing 222-S and 222-SA analytical and quality control activities. The 222-S Laboratory provides analytical services to various clients including, but not limited to, waste characterization for the Tank Waste Remediation Systems (TWRS), waste characterization for regulatory waste treatment, storage, and disposal (TSD), regulatory compliance samples, radiation screening, process samples, and TPA samples. A graded approach is applied on the level of sample custody, QC, data verification, and data reporting to meet the specific needs of the client

  4. Develpment of quality assurance manual for fabrication of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT.

  5. Develpment of quality assurance manual for fabrication of DUPIC fuel

    International Nuclear Information System (INIS)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT

  6. Quality assurance in the project of RECH-2 research reactor

    International Nuclear Information System (INIS)

    Goycolea Donoso, C.; Nino de Zepeda Schele, A.

    1989-01-01

    The implantation of a Quality Assurance Program for the design, supply, construction, installation, and testing of the RECH-2 research reactor, is described in this paper. The obtained results, demonstrate that a Quality Assurance Program constitutes a suitable mean to assure that the installation complies with the safety and reliability requirements. (author)

  7. Quality assurance during site construction. Pt. 1

    International Nuclear Information System (INIS)

    Mueller, J.

    1980-01-01

    The first part of the lecture deals with the Quality Assurance system on the construction site in general. Basic site-related problems during contract implementation and the QA system requirements resulting from them are presented. The compilation of these requirements in a QA program and its inclusion in the site manual in written form are explained. Site organization, personnel qualification and procedures are referred to. Whereas the first part shows what is to be done, the second part shows how it can be put into practice on the site. All the essential points for the assurance of quality are addressed. They include, e.g., review of documents, incoming goods control, in-process surveillance, store controls, identification of components and systems, dealing with changes and deviations, documentation control and audits. By means of examples taken form practice the necessity of a well-functioning QA system, and the importance of quality-assuring measures on the site are pointed out. (orig.)

  8. General review of quality assurance system requirements. The utility or customer requirement

    International Nuclear Information System (INIS)

    Fowler, J.L.

    1976-01-01

    What are the customer's Quality Assurance requirements and how does he convey these to his contractor, or apply them to himself. Many documents have been prepared mostly by countries with high technology availability and it is significant to note that many of the documents, particularly those of the United States of America, were prepared for nuclear safety related plant, but the logic of these documents equally applied to heavy engineering projects that are cost effective, and this is the current thinking and practice within the CEGB (Central Electricity Generating Board). Some documents have legislative backing, others rely on contractual disciplines, but they all appear to repeat the same basic requirements, so why does one continue to write more documents. The basic problem is that customers have to satisfy differing national legislative, economic and commercial requirements and, like all discerning customers, wish to reserve the right to satisfy their own needs, which are very often highly specialized. The CEGB are aware of this problem and are actively co-operating with most of the national and international authorities who are leading in this field, with a view to obtaining compatibility of requirements, but now there still remains the problem of satisfying national custom and practice. (author)

  9. Quality assurance inspections for shipping and storage containers

    Energy Technology Data Exchange (ETDEWEB)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier`s quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ``inspection tree.``The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities.

  10. Quality assurance inspections for shipping and storage containers

    International Nuclear Information System (INIS)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H.

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier's quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ''inspection tree.''The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities

  11. Quality Assurance Program Description

    Energy Technology Data Exchange (ETDEWEB)

    Halford, Vaughn Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ryder, Ann Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Effective May 1, 2017, led by a new executive leadership team, Sandia began operating within a new organizational structure. National Technology and Engineering Solutions of Sandia (Sandia’s) Quality Assurance Program (QAP) was established to assign responsibilities and authorities, define workflow policies and requirements, and provide for the performance and assessment of work.

  12. AVLIS Production Plant Preliminary Quality Assurance Plan and Assessment

    International Nuclear Information System (INIS)

    1984-01-01

    This preliminary Quality Assurance Plan and Assessment establishes the Quality Assurance requirements for the AVLIS Production Plant Project. The Quality Assurance Plan defines the management approach, organization, interfaces, and controls that will be used in order to provide adequate confidence that the AVLIS Production Plant design, procurement, construction, fabrication, installation, start-up, and operation are accomplished within established goals and objectives. The Quality Assurance Program defined in this document includes a system for assessing those elements of the project whose failure would have a significant impact on safety, environment, schedule, cost, or overall plant objectives. As elements of the project are assessed, classifications are provided to establish and assure that special actions are defined which will eliminate or reduce the probability of occurrence or control the consequences of failure. 8 figures, 18 tables

  13. Assessment of Quality Assurance Measures for Radioactive Material Transport Packages not Requiring Competent Authority Design Approval - 13282

    International Nuclear Information System (INIS)

    Komann, Steffen; Groeke, Carsten; Droste, Bernhard

    2013-01-01

    The majority of transports of radioactive materials are carried out in packages which don't need a package design approval by a competent authority. Low-active radioactive materials are transported in such packages e.g. in the medical and pharmaceutical industry and in the nuclear industry as well. Decommissioning of NPP's leads to a strong demand for packages to transport low and middle active radioactive waste. According to IAEA regulations the 'non-competent authority approved package types' are the Excepted Packages and the Industrial Packages of Type IP-1, IP-2 and IP-3 and packages of Type A. For these types of packages an assessment by the competent authority is required for the quality assurance measures for the design, manufacture, testing, documentation, use, maintenance and inspection (IAEA SSR 6, Chap. 306). In general a compliance audit of the manufacturer of the packaging is required during this assessment procedure. Their regulatory level in the IAEA regulations is not comparable with the 'regulatory density' for packages requiring competent authority package design approval. Practices in different countries lead to different approaches within the assessment of the quality assurance measures in the management system as well as in the quality assurance program of a special package design. To use the package or packaging in a safe manner and in compliance with the regulations a management system for each phase of the life of the package or packaging is necessary. The relevant IAEA-SSR6 chap. 801 requires documentary verification by the consignor concerning package compliance with the requirements. (authors)

  14. Assessment of Quality Assurance Measures for Radioactive Material Transport Packages not Requiring Competent Authority Design Approval - 13282

    Energy Technology Data Exchange (ETDEWEB)

    Komann, Steffen; Groeke, Carsten; Droste, Bernhard [BAM Federal Institute for Materials Research and Testing, Unter den Eichen 44-46, 12203 Berlin (Germany)

    2013-07-01

    The majority of transports of radioactive materials are carried out in packages which don't need a package design approval by a competent authority. Low-active radioactive materials are transported in such packages e.g. in the medical and pharmaceutical industry and in the nuclear industry as well. Decommissioning of NPP's leads to a strong demand for packages to transport low and middle active radioactive waste. According to IAEA regulations the 'non-competent authority approved package types' are the Excepted Packages and the Industrial Packages of Type IP-1, IP-2 and IP-3 and packages of Type A. For these types of packages an assessment by the competent authority is required for the quality assurance measures for the design, manufacture, testing, documentation, use, maintenance and inspection (IAEA SSR 6, Chap. 306). In general a compliance audit of the manufacturer of the packaging is required during this assessment procedure. Their regulatory level in the IAEA regulations is not comparable with the 'regulatory density' for packages requiring competent authority package design approval. Practices in different countries lead to different approaches within the assessment of the quality assurance measures in the management system as well as in the quality assurance program of a special package design. To use the package or packaging in a safe manner and in compliance with the regulations a management system for each phase of the life of the package or packaging is necessary. The relevant IAEA-SSR6 chap. 801 requires documentary verification by the consignor concerning package compliance with the requirements. (authors)

  15. Regulatory requirements and quality assurance of radiation monitoring instruments

    International Nuclear Information System (INIS)

    Narasimharao, K.L.; Sharma, Ranjit

    2005-01-01

    The successful utilisation of radiation sources in the fields of medicine and industry requires the accurate measurement of activity, exposure rate and dose. Many varieties of instruments are in use for measurement of these parameters and new ones are being developed. The criteria for the design of the radiation monitoring instrument include the type and intensity of the radiation, purpose of measurement and ruggedness of the instrument. Quality and reliability of radiation monitoring instruments ensure that individuals are adequately protected. Accuracy, response time and ruggedness are required to be as per the approved/ prescribed guidelines. Regulatory authorities outline the design and performance criteria for radiation monitoring instruments and prescribe the recommendations of international agencies such as IAEA, ICRU and ISO for radiological measurement assurance programme. National Standards Laboratories all over the world prescribe procedures for calibration of various radiation monitoring instruments. The instruments should be calibrated as per these guidelines and should be traceable to national standards. The calibration traceable to national/ international standards and documentation as well as limits stipulated by the competent authority ensures the expected performance of the instrument. (author)

  16. Quality Assurance in Custom Dental Devices: A Technologist's Perspective.

    Science.gov (United States)

    Griffin, Anthony

    2017-12-01

    Manufacturing of custom-made dental devices such as removable dentures, fixed prosthodontics and orthodontics are subject to the requirements of the Medical Devices Directive (MDD). Many dental laboratories often enhance these requirements by implementing quality assurance procedures that then provide enhanced consistency. this paper provides a dental technologist's view of some of the systems currently being used in dental laboratories to provide a quality assured product and associated issues.

  17. Introduction to quality assurance

    International Nuclear Information System (INIS)

    Raisic, N.

    1980-01-01

    Safety requirements set forth in the regulatory requirement, codes, standards as well as other requirements for various aspects of nuclear power plant design and operation are strictly implemented through QA activities. The overall QA aim is to assure that the plant is soundly and correctly designed and that it is built, tested and operated in accordance with stringent quality standards and conservative engineering practices. In this way a high degree of freedom from faults and errors can be achieved. (orig.)

  18. Quality assurance program plan for 324 Building B-Cell safety cleanout project (BCCP)

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides information on how the Quality Assurance Program is implemented for the 324 Building B-Cell Safety Cleanout Project (BCCP). This QAPP is responsive to the Westinghouse Hanford Company Quality Assurance Program and Implementation Plan, WHC-SP-1131, for 10 CFR 830.120, Nuclear Safety Management, Quality Assurance Requirements; and DOE Order 5700.6C, Quality Assurance. This QAPP supersedes PNNL PNL-MA-70 QAP Quality Assurance Plan No. WTC-050 Rev. 2, issue date May 3, 1996. This QAPP has been developed specifically for the BCCP. It applies to those items and tasks which affect the completion of activities identified in the work breakdown structure of the Project Management Plan (PMP). These activities include all aspects of decontaminating B-Cell and project related operations within the 324 Building as it relates to the specific activities of this project. General facility activities (i.e. 324 Building Operations) are covered in the Building 324 QAPP. In addition, this QAPP supports the related quality assurance activities addressed in CM-2-14, Hazardous Material Packaging and Shipping, and HSRCM-1, Hanford Site Radiological Control Manual, The 324 Building is currently transitioning from being a Pacific Northwest National Laboratory (PNNL) managed facility to a B and W Hanford Company (BWHC) managed facility. During this transition process existing, PNNL procedures and documents will be utilized until replaced by BWHC procedures and documents. These documents conform to the requirements found in PNL-MA-70, Quality Assurance Manual and PNL-MA-8 1, Hazardous Materials Shipping Manual. The Quality Assurance Program Index (QAPI) contained in Table 1 provides a matrix which shows how project activities relate to 10 CFR 83 0.120 and 5700.6C criteria. Quality Assurance program requirements will be addressed separate from the requirements specified in this document. Other Hanford Site organizations/companies may be

  19. Application of project design peer review to improve quality assurance

    International Nuclear Information System (INIS)

    McClure, F.E.

    1989-01-01

    DOE ORDER 5481.1B Safety Analysis and Review Systems and DOE ORDER 6430.1A General Design Criteria require that the design of facilities shall incorporate the necessary Quality Assurance review requirements to assure that the established program quality assurance objectives are met in the design criteria and the construction documents. The use of Project Design Peer Review to satisfy these requirements is presented. The University of California manages the Lawrence Berkeley Laboratory, the Lawrence Livermore National Laboratory, and the Los Alamos National Scientific Laboratory. The 1988 University Seismic Safety Policy requires the use of independent Project Design Peer Review in its capital improvement and seismic reconstruction program

  20. MDEP VICWG-02 Technical Report - Survey on quality assurance program requirements

    International Nuclear Information System (INIS)

    2011-01-01

    The survey was prepared using the requirements of Appendix B to 10 CFR Part 50, 'Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants'. These requirements form the basis upon which the U.S. NRC oversees the activities of vendors providing parts and services to the commercial U.S. nuclear power industry. As discussed and agreed to at the October 2008 Vendor Inspection Cooperation Working Group meeting in Dijon, France, the survey that follows was developed using these requirements. The survey is divided into the 18 basic criteria of Appendix B to 10 CFR Part 50. Within each criteria there are individual requirements that have been identified as separate and distinct elements that are covered during the inspection of vendor activities. In addition to the requirements of Appendix B to 10 CFR Part 50, the requirements of 10 CFR Part 21, 'Reporting of Defects and Non-compliance', have been listed at the end of the survey as an example of 'Other Requirements Related To Vendor Inspections', for the NRC. (authors)

  1. Large hadron collider (LHC) project quality assurance plan

    Energy Technology Data Exchange (ETDEWEB)

    Gullo, Lisa; Karpenko, Victor; Robinson, Kem; Turner, William; Wong, Otis

    2002-09-30

    The LHC Quality Assurance Plan is a set of operating principles, requirements, and practices used to support Berkeley Lab's participation in the Large Hadron Collider Project. The LHC/QAP is intended to achieve reliable, safe, and quality performance in the LHC project activities. The LHC/QAP is also designed to fulfill the following objectives: (1) The LHC/QAP is Berkeley Lab's QA program document that describes the elements necessary to integrate quality assurance, safety management, and conduct of operations into the Berkeley Lab's portion of the LHC operations. (2) The LHC/QAP provides the framework for Berkeley Lab LHC Project administrators, managers, supervisors, and staff to plan, manage, perform, and assess their Laboratory work. (3) The LHC/QAP is the compliance document that conforms to the requirements of the Laboratory's Work Smart Standards for quality assurance (DOE O 414.1, 10 CFR 830.120), facility operations (DOE O 5480.19), and safety management (DOE P 450.4).

  2. Large hadron collider (LHC) project quality assurance plan

    International Nuclear Information System (INIS)

    Gullo, Lisa; Karpenko, Victor; Robinson, Kem; Turner, William; Wong, Otis

    2002-01-01

    The LHC Quality Assurance Plan is a set of operating principles, requirements, and practices used to support Berkeley Lab's participation in the Large Hadron Collider Project. The LHC/QAP is intended to achieve reliable, safe, and quality performance in the LHC project activities. The LHC/QAP is also designed to fulfill the following objectives: (1) The LHC/QAP is Berkeley Lab's QA program document that describes the elements necessary to integrate quality assurance, safety management, and conduct of operations into the Berkeley Lab's portion of the LHC operations. (2) The LHC/QAP provides the framework for Berkeley Lab LHC Project administrators, managers, supervisors, and staff to plan, manage, perform, and assess their Laboratory work. (3) The LHC/QAP is the compliance document that conforms to the requirements of the Laboratory's Work Smart Standards for quality assurance (DOE O 414.1, 10 CFR 830.120), facility operations (DOE O 5480.19), and safety management (DOE P 450.4)

  3. Project quality assurance plant: Sodium storage facility, project F-031

    International Nuclear Information System (INIS)

    Shultz, J.W.; Shank, D.R.

    1994-11-01

    The Sodium Storage Facility Project Quality Assurance Plan delineates the quality assurance requirements for construction of a new facility, modifications to the sodium storage tanks, and tie-ins to the FFTF Plant. This plan provides direction for the types of verifications necessary to satisfy the functional requirements within the project scope and applicable regulatory requirements determined in the Project Functional Design Criteria (FDC), WHC-SD-FF-FDC-009

  4. Quality assurance and reference material requirements and considerations for environmental sample analysis in nuclear forensics

    International Nuclear Information System (INIS)

    Swindle, D.W. Jr.; Perrin, R.E.; Goldberg, S.A.; Cappis, J.

    2002-01-01

    Full text: High-sensitivity nuclear environmental sampling and analysis techniques have been proven in their ability to verify declared nuclear activities, as well as to assist in the detection of undeclared nuclear activities and facilities. Following the Gulf War, the capability and revealing power of environmental sampling and analysis techniques to support international safeguards was demonstrated and subsequently adopted by the International Atomic Energy Agency (IAEA) as routine safeguards measures in safeguards inspections and verifications. In addition to having been proved useful in international safeguards, environmental sampling and analysis techniques have demonstrated their utility in identifying the origins of 'orphaned' nuclear material, as well as the origin of intercepted smuggled nuclear material. Today, environmental sampling and analysis techniques are now being applied in six broad areas to support nonproliferation, disarmament treaty verification, national and international nuclear security, and environmental stewardship of weapons production activities. Consequently, more and more laboratories around the world are establishing capabilities or expanding capabilities to meet these growing applications, and as such requirements for quality assurance and control are increasing. The six areas are: 1) Nuclear safeguards; 2) Nuclear forensics/illicit trafficking; 3) Ongoing monitoring and verification (OMV); 4) Comprehensive Test Ban Treaty (CTBT); 5) Weapons dismantlement/materials disposition; and 6) Research and development (R and D)/environmental stewardship/safety. Application of environmental sampling and analysis techniques and resources to illicit nuclear material trafficking, while embodying the same basic techniques and resources, does have unique requirements for sample management, handling, protocols, chain of custody, archiving, and data interpretation. These requirements are derived from needs of how data from nuclear forensics

  5. Transuranic Waste Characterization Quality Assurance Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-30

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes.

  6. Transuranic Waste Characterization Quality Assurance Program Plan

    International Nuclear Information System (INIS)

    1995-01-01

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes

  7. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  8. Quality management and quality assurance contracts

    International Nuclear Information System (INIS)

    Teichler, M.

    1991-01-01

    Quality assurance contracts belong to the most important instruments of quality management systems. As a result of such contracts, quality control is to be done not only by the buyer, but is made a task to be fulfilled by the manufacturer. The author of the article shows that quality assurance contracts do change the contractual relationship between supplier and buyer, but have no effect on economic and practical conditions. This is so because quality assurance contracts apply only to warranty claims, which play a subordinate role in the legal relationship between producer and buyer, or producer and consumer, as compared to the claims for damages arising out of the contracts. (orig.) [de

  9. Near-Facility Environmental Monitoring Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    MCKINNEY, S.M.

    2000-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near-facility environmental monitoring directed by Waste Management Technical Services and supersedes HNF-EP-0538-4. This plan applies to all sampling and monitoring activities performed by Waste Management Technical Services in implementing near-facility environmental monitoring at the Hanford Site. This Quality Assurance Project Plan is required by U.S. Department of Energy Order 5400.1 (DOE 1990) as a part of the Environmental Monitoring Plan (DOE-RL 1997) and is used to define: Environmental measurement and sampling locations used to monitor environmental contaminants near active and inactive facilities and waste storage and disposal sites; Procedures and equipment needed to perform the measurement and sampling; Frequency and analyses required for each measurement and sampling location; Minimum detection level and accuracy; Quality assurance components; and Investigation levels. Near-facility environmental monitoring for the Hanford Site is conducted in accordance with the requirements of U.S. Department of Energy Orders 5400.1 (DOE 1990), 5400.5 (DOE 1993), 5484.1 (DOE 1990), and 435.1 (DOE 1999), and DOE/EH-O173T (DOE 1991). It is Waste Management Technical Services' objective to manage and conduct near-facility environmental monitoring activities at the Hanford Site in a cost-effective and environmentally responsible manner that is in compliance with the letter and spirit of these regulations and other environmental regulations, statutes, and standards

  10. Near-facility environmental monitoring quality assurance project plan

    International Nuclear Information System (INIS)

    McKinney, S.M.

    1997-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near facility environmental monitoring performed by Waste Management Federal Services, Inc., Northwest Operations and supersedes WHC-EP-0538-2. This plan applies to all sampling and monitoring activities performed by waste management Federal Services, Inc., Northwest Operations in implementing facility environmental monitoring at the Hanford Site

  11. Quality assurance as a management tool in decommissioning activities

    International Nuclear Information System (INIS)

    Arter, D.R.

    1982-01-01

    Quality assurance practices have been applied to the peaceful use of nuclear energy for many years. These practices are just as useful to the back end of the nuclear energy cycle as they are to the front end. The Department of Energy requires the application of quality assurance to all of its projects and programs. Quality assurance as a management tool consists of three fundamental elements: planning, execution and control. These elements should be applied to decommissioning activities by all parties, such that limited funds are wisely spent and the public is adequately protected

  12. Quality assurance and reliability

    International Nuclear Information System (INIS)

    Normand, J.; Charon, M.

    1975-01-01

    Concern for obtaining high-quality products which will function properly when required to do so is nothing new - it is one manifestation of a conscientious attitude to work. However, the complexity and cost of equipment and the consequences of even temporary immobilization are such that it has become necessary to make special arrangements for obtaining high-quality products and examining what one has obtained. Each unit within an enterprise must examine its own work or arrange for it to be examined; a unit whose specific task is quality assurance is responsible for overall checking, but does not relieve other units of their responsibility. Quality assurance is a form of mutual assistance within an enterprise, designed to remove the causes of faults as far as possible. It begins very early in a project and continues through the ordering stage, construction, start-up trials and operation. Quality and hence reliability are the direct result of what is done at all stages of a project. They depend on constant attention to detail, for even a minor piece of poor workmanship can, in the case of an essential item of equipment, give rise to serious operational difficulties

  13. 10 CFR 71.37 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 71.37 Section 71.37 Energy NUCLEAR... Package Approval § 71.37 Quality assurance. (a) The applicant shall describe the quality assurance program... quality assurance program that are applicable to the particular package design under consideration...

  14. Quality Assurance program plan - plutonium stabilization and handling project W-460

    International Nuclear Information System (INIS)

    SCHULTZ, J.W.

    1999-01-01

    This Quality Assurance Program Plan (QAPP) identifies Project Quality Assurance (QA) program requirements for all parties participating in the design, procurement, demolition, construction, installation, inspection and testing for Project W-460

  15. Department of Energy hazardous waste remedial actions program: Quality assurance program

    International Nuclear Information System (INIS)

    Horne, T.E.

    1988-01-01

    This paper describes the Quality Assurance Program developed for the Hazardous Waste Remedial Actions Program Support Contractor Office (HAZWRAP SCO). Key topics discussed include an overview of the HAZWRAP SCO mission and organization, the basic quality assurance program requirements and the requirements for the control of quality for the Department of Energy and Work for Others hazardous waste management programs, and the role of ensuring quality through the project team concept for the management of remedial response actions. The paper focuses on planning for quality assurance for this remedial waste management process from preliminary assessments of remedial sites to feasibility studies. Some observations concerning the control of quality during the implementation of remedial actions are presented. (2 refs.)

  16. Qualification of quality assurance program audit personnel for nuclear power plants - August 1980

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Appendix B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants, to 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, establishes overall quality assurance requirements for the design, construction, and operation of safety-related structures, and components of nuclear power plants. Criterion XVIII, Audits, of Appendix B establishes requirements for conducting audits of the quality assurance program. This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to qualification of quality assurance program audit personnel for nuclear power plants

  17. Quality assurance in the structural installations of nuclear power stations

    International Nuclear Information System (INIS)

    Schnellenbach, G.; Wrage, S.

    1985-01-01

    The concept of quality assurance distinguishes between self-monitoring of the design, manufacturing and executing firms and external monitoring by state institutions or by experts commissioned by them. The long-term control of structures is within the area of responsibility of the owner. This quality assurance concept is controlled in detail by statutes, which clearly define responsibilities. This structural engineering quality assurance system also forms the basis for the design, construction and utilization of structural installations of nuclear power stations; requirements emanating from the Atomic Energy Acts for the structural installations demand, however, to some extent a sharpening of self- and external monitoring. Therefore, today a quality concept has been developed for the important engineering safety-related buildings of nuclear power stations. This concept takes account of the strict requirements imposed and fulfils the requirement of KTA 1401. (orig.) [de

  18. Quality Assurance of Ultrasonic Diagnosis in Breast

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Kim, Hong Dae [Hallym University, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of)

    2006-06-15

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  19. Quality Assurance of Ultrasonic Diagnosis in Breast

    International Nuclear Information System (INIS)

    Chung, Soo Young; Kim, Hong Dae

    2006-01-01

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  20. Manufacturing and quality assurance for the MFTF superconductor core

    International Nuclear Information System (INIS)

    Scanlan, R.M.; Johnston, J.E.; Waide, P.A.; Zeitlin, B.A.; Smith, G.B.; Nelson, C.T.

    1979-01-01

    A total of 55,000 m of multifilamentary Nb-Ti superconductor in minimum lengths of 380 m are required for the Mirror Fusion Test Facility. This conductor is a large cross-section monolith and, as such, has presented several new manufacturing challenges. In addition, a monolith requires more stringent quality assurance procedures than braids or cables. This paper describes the manufacturing steps and the quality assurance program which have been developed for the MFTF superconductor core

  1. Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

    Science.gov (United States)

    Lee, Pen-Nan

    1991-01-01

    Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

  2. Rapid quality assurance with Requirements Smells

    OpenAIRE

    Femmer, H.; Fernández, D. Méndez; Wagner, S.; Eder, S.

    2016-01-01

    Bad requirements quality can cause expensive consequences during the software development lifecycle, especially if iterations are long and feedback comes late. %-- the faster a problem is found, the cheaper it is to fix. This makes explicit the need of a lightweight detection mechanism of requirements quality violations. We aim at a light-weight static requirements analysis approach that allows for rapid checks immediately when requirements are written down. We transfer the concept of code sm...

  3. Chapter 8: Quality assurance

    International Nuclear Information System (INIS)

    2001-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (UJD) have been focused on inspection of quality assurance programmes of Slovak Power Stations, plc. and its daughter companies at Bohunice and Mochovce. Two quality assurance inspections in the area of periodical in service inspections (V-2 units) and tests of selected equipment (NPP V-2 units) and operation control (V-1 units) has been performed at NPPs Bohunice. One violation of decree on quality assurance of selected equipment has been found in the area of documentation archiving. The inspection concerning the implementation of quality assurance programme for operation of NPP Mochovce in the area of operation control has been performed focused on safety aspects of operation, operational procedures, control of operational events and feedback from operational experience. The results of this inspection were positive. Inspection of implementation of quality assurance programme for operation of radioactive waste repository (RU RAW) at the Mochovce location has been performed focused on receiving of containers, with radioactive wastes, containers handling, radiation monitoring, activities of documentation control and radiation protection at the repository site. No serious deficiencies have been found out. Also one inspection of experimental nuclear installations of VUJE Trnava at Jaslovske Bohunice site has been performed focused on procurement control, quality audits, documentation and quality records control when performing activities at experimental nuclear installations. The activity on development of internal quality assurance system continued. The implementation of this system will assure quality and effective fulfilment enlarged tasks of UJD with limited resources for its activity. The analyses of possible use of existing internal administrative control documentation as a basis for future quality system procedures was performed in co-operation with an external specialised organisation. The

  4. Quality assurance for safety in the radioactive waste management: a quality assurance system in Novi Han radioactive waste repository

    International Nuclear Information System (INIS)

    Petrova, A.; Kolev, I.

    2000-01-01

    Novi Han Radioactive Waste Repository (RWR) is still the only place in Bulgaria for storage of low and intermediate level radioactive waste. It is necessary to establish and maintain a Quality Assurance (QA) system to ensure that the RWR can be operated safely with regard to the health and safety of the general public and site personnel. A QA system has to establish the basic requirements for quality assurance in order to enhance nuclear safety by continuously improving the methods employed to achieve quality. It is envisaged that the QA system for the Novi Han RWR will cover the operation and maintenance of the radioactive waste disposal facilities, the radiation protection and monitoring of the site, as well as the scientific and technology development aspects. The functions of the Novi Han RWR presume the availability of an environmental management system. It is appropriate to establish a QA system based on the requirements of the ISO Standards 9001 and 14000, using the recommendations of the IAEA (Quality assurance for safety in NPPs and other nuclear installations, code and safety guides Q1-Q14). (authors)

  5. Quality assurance in radiodiagnosis

    International Nuclear Information System (INIS)

    Ghilardi Netto, T.; Sao Paulo Univ., Ribeirao Preto

    1983-01-01

    The following topics are dealt with: 1) the importance of the application of a quality assurance program in radiodiagnosis, with its main consequences : improvement of imaging quality, reduction of the patient expossure rate, cost reduction and 2) how to introduce the quality assurance control in the radiodiagnostic area. (M.A.) [pt

  6. Quality assurance in a large research and development laboratory

    International Nuclear Information System (INIS)

    Neill, F.H.

    1980-01-01

    Developing a quality assurance program for a large research and development laboratory provided a unique opportunity for innovative planning. The quality assurance program that emerged has been tailored to meet the requirements of several sponsoring organizations and contains the flexibility for experimental programs ranging from large engineering-scale development projects to bench-scale basic research programs

  7. Application of quality assurance to MC and A systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Application of the principles of quality assurance to MC and A has been done at DOE's Savannah River Operations Office. The principles were applied to the functions within the MC and A Branch, including both the functions used to operate the Branch and those used to review the MC and A activities of DOE/SR's contractor. The purpose of this paper is to discuss that application of quality assurance and to show how the principles of quality assurance relate to the functions of a MC and A system, for both a DOE field office and a contractor. The principles (presented as requirements from the NQA-1 standard) are briefly discussed, a method for applying quality assurance is outlined, application at DOE/SR is shown, and application to a contractor's MC and A system is discussed

  8. The role of the EPA radiation quality assurance program in the measurement quality assurance accreditation program for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Grady, T.M. [Environmental Monitoring Systems Laboratory, Las Vegas, NV (United States)

    1993-12-31

    As the nature and extent of radiological contamination becomes better documented and more public, radioanalytical laboratories are faced with a constantly expanding variety of new and difficult analytical requirements. Concurrent with those requirements is the responsibility to provide customers, regulatory officials, or the public with defensible data produced in an environment of verifiable, controlled quality. To meet that need, a quality assurance accreditation program for radioassay laboratories has been proposed by the American National Standards Institute (ANSI). The standard will provide the organizational framework and functional requirements needed to assure the quality of laboratory outputs. Under the proposed program, the U.S. Environmental Protection Agency`s (EPA`s) Laboratory Intercomparison Program plays a key role as a reference laboratory. The current and proposed roles of the EPA Intercomparison Program are discussed, as are the functional relationships between EPA, the accreditating organization, and the service and monitoring laboratories.

  9. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  10. Software quality assurance (SQA) for Savannah River reactors

    Energy Technology Data Exchange (ETDEWEB)

    Schaumann, C.M.

    1990-01-01

    Over the last 25 years, the Savannah River Site (SRS) has developed a strong Software Quality Assurance (SQA) program. It provides the information and management controls required of a high quality auditable system. The SRS SQA program provides the framework to meet the requirements in increasing regulation.

  11. Quality Assurance Project Plan Development Tool

    Science.gov (United States)

    This tool contains information designed to assist in developing a Quality Assurance (QA) Project Plan that meets EPA requirements for projects that involve surface or groundwater monitoring and/or the collection and analysis of water samples.

  12. Metrology's role in quality assurance

    International Nuclear Information System (INIS)

    Zeederberg, L.B.

    1982-01-01

    Metrology, the science of measurement, is playing an increasing role in modern industry as part of an on-going quality assurance programme. At Escom, quality assurance was critical during the construction of the Koeberg nuclear facility, and also a function in controlling services provided by Escom. This article deals with the role metrology plays in quality assurance

  13. Software quality assurance handbook

    Energy Technology Data Exchange (ETDEWEB)

    1990-09-01

    There are two important reasons for Software Quality Assurance (SQA) at Allied-Signal Inc., Kansas City Division (KCD): First, the benefits from SQA make good business sense. Second, the Department of Energy has requested SQA. This handbook is one of the first steps in a plant-wide implementation of Software Quality Assurance at KCD. The handbook has two main purposes. The first is to provide information that you will need to perform software quality assurance activities. The second is to provide a common thread to unify the approach to SQA at KCD. 2 figs.

  14. ERD UMTRA Project quality assurance program plan, Revision 7

    International Nuclear Information System (INIS)

    1995-09-01

    This document is the revised Quality Assurance Program Plan (QAPP) dated September, 1995 for the Environmental Restoration Division (ERD) Uranium Mill Tailings Remedial Action Project (UMTRA). Quality Assurance requirements for the ERD UMTRA Project are based on the criteria outlined in DOE Order 5700.6C or applicable sections of 10 CFR 830.120. QA requirements contained in this QAPP shall apply to all personnel, processes, and activities, including planning, scheduling, and cost control, performed by the ERD UMTRA Project and its contractors

  15. Software requirements elicitation to support internal monitoring of quality assurance system for higher education in Indonesia

    Science.gov (United States)

    Amalia, A.; Gunawan, D.; Hardi, S. M.; Rachmawati, D.

    2018-02-01

    The Internal Quality Assurance System (in Indonesian: SPMI (Sistem Penjaminan Mutu Internal) is a systemic activity of quality assurance of higher education in Indonesia. SPMI should be done by all higher education or universities in Indonesia based on the Regulation of the Minister of Research, Technology and Higher Education of the Republic of Indonesia Number 62 of 2016. Implementation of SPMI must refer to the principle of SPMI that is independent, standardize, accurate, well planned and sustainable, documented and systematic. To assist the SPMI cycle properly, universities need a supporting software to monitor all the activities of SPMI. But in reality, many universities are not optimal in building this SPMI monitoring system. One of the obstacles is the determination of system requirements in support of SPMI principles is difficult to achieve. In this paper, we observe the initial phase of the engineering requirements elicitation. Unlike other methods that collect system requirements from users and stakeholders, we find the system requirements of the SPMI principles from SPMI guideline book. The result of this paper can be used as a choice in determining SPMI software requirements. This paper can also be used by developers and users to understand the scenario of SPMI so that could overcome the problems of understanding between this two parties.

  16. Underground Test Area Quality Assurance Project Plan Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Irene Farnham

    2011-05-01

    This Quality Assurance Project Plan (QAPP) provides the overall quality assurance (QA) program requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) Sub-Project (hereafter the Sub-Project) activities. The requirements in this QAPP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). The QAPP Revision 0 supersedes DOE--341, Underground Test Area Quality Assurance Project Plan, Nevada Test Site, Nevada, Revision 4.

  17. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  18. Software quality assurance

    CERN Document Server

    Laporte, Claude Y

    2018-01-01

    This book introduces Software Quality Assurance (SQA) and provides an overview of standards used to implement SQA. It defines ways to assess the effectiveness of how one approaches software quality across key industry sectors such as telecommunications, transport, defense, and aerospace. * Includes supplementary website with an instructor's guide and solutions * Applies IEEE software standards as well as the Capability Maturity Model Integration for Development (CMMI) * Illustrates the application of software quality assurance practices through the use of practical examples, quotes from experts, and tips from the authors

  19. Implementation of quality assurance with respect to product quality and scheduling

    International Nuclear Information System (INIS)

    Schleimer, W.F.

    1986-04-01

    Quality assurance means the whole range of actions which are necessary to meet the client's requirements for the product and the test methods. Audits: The preconditions for fabrication must be fulfilled by approval of the manufacturer's quality assurance system, the staff's qualification, his procedures and his equipments. This is done by means of a system audit at KWU or an equivalent organisation. Specifications: For quality assurance the requirements for the components are fixed in specifications. There are material specifications, process/procedure specifications, components specifications. Approval of Component Design and Manufacture (Scheduling): The approval procedure of a structurally welded part is described as an example of the approval of component design and manufacture, thus representing one small piece of a mechanical equipment. In-Process Surveillance (Product Audit): At KWU the in-process surveillance is regulated by a KQ- or product audit concept. In this concept we have K- and KQ-steps. The list of KQ-steps will be presented. Documentation: All test or examination steps are documented with certificates, lists, and stamps for the final documentation. 19 figs

  20. HPV testing for primary cervical screening: Laboratory issues and evolving requirements for robust quality assurance.

    Science.gov (United States)

    Carozzi, Francesca Maria; Del Mistro, Annarosa; Cuschieri, Kate; Frayle, Helena; Sani, Cristina; Burroni, Elena

    2016-03-01

    This review aims to highlight the importance of Quality Assurance for Laboratories performing HPV test for Cervical Cancer Screening. An HPV test, to be used as primary screening test, must be validated according to international criteria, based on comparison of its clinical accuracy to HC2 or GP5+/6+ PCR-EIA tests. The number of validated platforms is increasing and appropriate Quality Assurance Programs (QAPs) which can interrogate longitudinal robustness and quality are paramount. This document describes the following topics: (1) the characteristics of an HPV laboratory and the personnel training needs, to ensure an elevated quality of the entire process and the optimal use of the resources; (2) the Quality Assurance, as both internal (IQA) and external quality assessment (EQA) systems, to be implemented and performed, and the description of the existing EQAs, including limitations; (3) general considerations for an optimal EQA program for hrHPV primary screening Due to the importance of Quality Assurance for this field, international efforts are necessary to improve QA International Collaboration. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  2. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  3. Research on quality assurance classification methodology for domestic AP1000 nuclear power projects

    International Nuclear Information System (INIS)

    Bai Jinhua; Jiang Huijie; Li Jingyan

    2012-01-01

    To meet the quality assurance classification requirements of domestic nuclear safety codes and standards, this paper analyzes the quality assurance classification methodology of domestic AP1000 nuclear power projects at present, and proposes the quality assurance classification methodology for subsequent AP1000 nuclear power projects. (authors)

  4. Quality assurance in plant engineering

    International Nuclear Information System (INIS)

    Ohsumi, Morimichi

    1977-01-01

    Quality assurance is defined as the intentional and systematic activity carried out to obtain such reliability that the functions of nuclear power generating plants are demonstrated during the plant operation, and the section in charge has the role to organize, adjust and communicate so that the related sections can work smoothly. There are many documents concerning the quality assurance, such as quality assurance basic program, quality assurance manual, quality control plan and its manual and many specifications, etc. The content of the quality assurance is different for every step of plant planning such as at inquiry and order receiving, and prior to manufacturing, for example, inspection specification being decided for the material and the welded parts of classified pipings at the step of order receiving. Document management, engineering schedule and the custody of quality records are also quality assurance activities. Design management is controlled step by step; plant planning including safety analysis, overall layout plan, conceptual design of buildings, aseismatic design guide, heat balance and so on, system design mainly with system description, piping design including piping specification, standard dimensions of edge preparation, piping and valve lists, inspection manual, etc., detailed design, standardization of piping and design review, etc. are explained. The management of the intermediate between soft and hard parts consists of the quality check for material manufacturers and shipment inspection, etc. (Nakai, Y.)

  5. Quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, B.M.; Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results.

  6. Quality assurance

    International Nuclear Information System (INIS)

    Gillespie, B.M.; Gleckler, B.P.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results

  7. Redefining and expanding quality assurance.

    Science.gov (United States)

    Robins, J L

    1992-12-01

    To meet the current standards of excellence necessary for blood establishments, we have learned from industry that a movement toward organization-wide quality assurance/total quality management must be made. Everyone in the organization must accept responsibility for participating in providing the highest quality products and services. Quality must be built into processes and design systems to support these quality processes. Quality assurance has been redefined to include a quality planning function described as the most effective way of designing quality into processes. A formalized quality planning process must be part of quality assurance. Continuous quality improvement has been identified as the strategy every blood establishment must support while striving for error-free processing as the long-term objective. The auditing process has been realigned to support and facilitate this same objective. Implementing organization-wide quality assurance/total quality management is one proven plan for guaranteeing the quality of the 20 million products that are transfused into 4 million patients each year and for moving toward the new order.

  8. How does one develop the right quality assurance program for waste management projects?

    International Nuclear Information System (INIS)

    Hedges, D.

    1988-01-01

    The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied to regulations and guidance documents to radioactive and hazardous waste programs. The wording of the Nuclear Regulatory Commission (NRC) quality assurance (QA) requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects providing one understands and uses the intent of the requirements. This paper describes the intent of existing QA requirements as they apply to radioactive and hazardous waste programs. Methods of ensuring that the quality assurance program design will be acceptable to DOE and regulatory agencies are illustrated

  9. How does one develop the right quality assurance program for waste management projects?

    International Nuclear Information System (INIS)

    Hedges, D.

    1988-01-01

    The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied by regulations and guidance documents to radioactive and hazardous waste programs. The wording of the NRC quality assurance requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects, providing one understands and uses the intent of the requirements. This paper describes the intent of existing QA requirements as they apply to radioactive and hazardous waste programs. Methods of ensuring that the quality assurance program design will be acceptable to DOE and regulatory agencies are illustrated

  10. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  11. Quality assurance program plan for the Site Physical and Electrical Calibration Services Lab. Revision 1

    International Nuclear Information System (INIS)

    Carpenter, C.A.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) is organized to address WHC's implementation of quality assurance requirements as they are presented as interpretive guidance endorsed by the Department of Energy (DOE) Field Office, Richland DOE Order 5700.6C Quality Assurance. The quality assurance requirements presented in this plan will assure Measuring and Test Equipment (M and TE) are in conformance with prescribed technical requirements and that data provided by testing, inspection, or maintenance are valid. This QAPP covers all activities and work elements that are variously called QA, quality control, and quality engineering regardless of the organization performing the work. This QAPP identifies the QA requirements for planning, control, and documentation of operations, modifications, and maintenance of the WHC Site Physical and Electrical Calibration Services Laboratory. The primary function of the WHC Site Physical and Electrical Calibration Services Laboratory is providing calibration, standardization, or repair service of M and TE

  12. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  13. Quality assurance terms and definitions - approved 1973

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Standards for certain terms and their definitions that are important to the uniform understanding of the intent of required quality assurance practices for the construction of nuclear power plants are presented

  14. UMTRA project technical assistance contractor quality assurance implementation plan

    International Nuclear Information System (INIS)

    1994-03-01

    The Uranium Mill Tailings Remedial Action (UMTRA) Project Technical Assistance contractor (TAC) Quality Assurance Implementation Plan (QAIP) outlines the primary requirements for integrating quality functions for TAC technical activities applied to the surface and ground water phases of the UMTRA Project. The QAIP is subordinate to the latest issue of the UMTRA Project TAC Quality Assurance Program Plan (QAPP) (DOE, 1993a), which was developed using US Department of Energy (DOE) Order 5700.6C quality assurance (QA) criteria. The QAIP addresses technical aspects of the TAC UMTRA Project surface and ground water programs. All QA issues in the QAIP shall comply with requirements contained in the TAC QAPP (DOE, 1933a). Because industry standards for data acquisition and data control are not addressed in DOE Order 5700.6C, the QAIP has been formatted to the 14 US Environmental Protection Agency (EPA) Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) QA requirements. DOE Order 5700.6C criteria that are not contained in the CERCLA requirements are added to the QAIP as additional requirements in Sections 15.0 through 18.0. Project documents that contain CERCLA requirements and 5700.6 criteria shall be referenced in this document to avoid duplication. Referenced documents are not included in this QAIP but are available through the UMTRA Project Document Control Center

  15. An approach to total quality assurance

    International Nuclear Information System (INIS)

    Archer, L.G.

    1976-01-01

    Total Quality Assurance must be based on amalgamating three quality functions: effective quality control, competent inspection, and regularly audited Quality Assurance programmes. In applying these functions the fuel supplier must regard each of his sub-contractors as part of his own works and ensure a common policy of motivated Quality Assurance throughout his own works and those of his suppliers. (author)

  16. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Frazier, T.P.

    1994-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the Facility Effluent Monitoring Plans, which are part of the overall Hanford Site Environmental Protection Plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of the individual Facility Effluent Monitoring Plans

  17. Auditing of quality assurance programs for nuclear power plants - September 1980 - (Rev.1)

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Appendix B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants, to 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, establishes overall quality assurance requirements for the design, construction, and operation of structures, systems, and components of nuclear power plants important to safety. Criterion XVIII, Audits, of Appendix B to 10 CFR Part 50 establishes requirements for conducting audits of the quality assurance program. This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to auditing of quality assurance programs for nuclear power plants. The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position

  18. Effluent monitoring Quality Assurance Project Plan for radioactive airborne emissions data. Revision 2

    International Nuclear Information System (INIS)

    Frazier, T.P.

    1995-12-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for compiling Hanford Site radioactive airborne emissions data. These data will be reported to the U.S. Environmental Protection Agency, the US Department of Energy, and the Washington State Department of Health. Effluent Monitoring performs compliance assessments on radioactive airborne sampling and monitoring systems. This Quality Assurance Project Plan is prepared in compliance with interim guidelines and specifications. Topics include: project description; project organization and management; quality assurance objectives; sampling procedures; sample custody; calibration procedures; analytical procedures; monitoring and reporting criteria; data reduction, verification, and reporting; internal quality control; performance and system audits; corrective actions; and quality assurance reports

  19. 7 CFR 652.7 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Quality assurance. 652.7 Section 652.7 Agriculture... assurance. (a) NRCS will review, in consultation with the Farm Service Agency, as appropriate, the quality... information obtained through its quality assurance process, documentation submitted by the technical service...

  20. 10 CFR 76.93 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 76.93 Section 76.93 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.93 Quality assurance. The Corporation shall establish, maintain, and execute a quality assurance program satisfying each of...

  1. Quality assurance inspections in the transportation packaging supplier industry

    International Nuclear Information System (INIS)

    Jankovich, J.P.

    1991-01-01

    In this paper the quality assurance inspections of the transportation packaging supplier industry, conducted by the U.S. Nuclear Regulatory Commission (NRC) on a routine basis since 1989 are discussed. The term supplier is used to include designers, fabricators, and distributors that hold NRC approved Quality Assurance Programs and Certificates of Compliance for packagings to transport radioactive materials. The objective of the inspections is to provide assurance that transportation packagings are fabricated and procured in accordance with 10 CFR Parts 21 and 71 requirements. The inspections are conducted in a systematic and comprehensive manner, utilizing uniform inspection techniques in order to assure uniformity and comparability. During the April 1989 and May 1991 period approximately 21 inspections were conducted by the Transportation Branch, Office of Nuclear Material Safety and Safeguards of the NRC. The majority of the findings were identified in the areas of quality assurance procedures, control of special processes (e.g. welding, radiography), and maintenance of QA records

  2. 10 CFR 63.142 - Quality assurance criteria.

    Science.gov (United States)

    2010-01-01

    ... planned and periodic audits to verify compliance with all aspects of the quality assurance program and to... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance criteria. 63.142 Section 63.142 Energy... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.142 Quality assurance criteria. (a) Introduction...

  3. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  4. Nuclear quality assurance operating philosophy: A quality-oriented approach

    International Nuclear Information System (INIS)

    Corcoran, W.R.; Geiger, J.E.; Heibel, R.E.; Cotton, J.B.; Sabol, A.R.

    1992-01-01

    Quality assurance programs have been part of the nuclear utility management process since the publication of the draft of 10CFR50 Appendix B in the late 1960s. The unwritten operational philosophy of nuclear quality assurance organizations focused on compliance with federal regulations. Adverse experiences, including operational events and extended shutdowns, prompted the gradual adoption of isolated practices extending beyond compliance orientation. These practices have an orientation that accommodates a definition of quality, a perspective of the role of nuclear quality assurance organizations in the overall concept of defense-in-depth, a definition of the segments of the nuclear quality assurance mission, and recent advances in the understanding of self-assessment. Observation of these practices at various nuclear utilities resulted in a syntheses of practices and approaches into a coherent quality-oriented nuclear quality assurance operating philosophy that is not totally adopted at any one utility

  5. BYU Food Quality Assurance Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Quality Assurance Lab is located in the Eyring Science Center in the department of Nutrition, Dietetics, and Food Science. The Quality Assurance Lab has about 10...

  6. Los Alamos National Laboratory transuranic waste quality assurance project plan. Revision 1

    International Nuclear Information System (INIS)

    1997-01-01

    This Transuranic (TRU) Waste Quality Assurance Project Plan (QAPjP) serves as the quality management plan for the characterization of transuranic waste in preparation for certification and transportation. The Transuranic Waste Characterization/Certification Program (TWCP) consists of personnel who sample and analyze waste, validate and report data; and provide project management, quality assurance, audit and assessment, and records management support, all in accordance with established requirements for disposal of TRU waste at the Waste Isolation Pilot Plant (WIPP) facility. This QAPjP addresses how the TWCP meets the quality requirements of the Carlsbad Area Office (CAO) Quality Assurance Program Description (QAPD) and the technical requirements of the Transuranic Waste Characterization Quality Assurance Program Plan (QAPP). The TWCP characterizes and certifies retrievably stored and newly generated TRU waste using the waste selection, testing, sampling, and analytical techniques and data quality objectives (DQOs) described in the QAPP, the Los Alamos National Laboratory Transuranic Waste Certification Plan (Certification Plan), and the CST Waste Management Facilities Waste Acceptance Criteria and Certification [Los Alamos National Laboratory (LANL) Waste Acceptance Criteria (WAC)]. At the present, the TWCP does not address remote-handled (RH) waste

  7. Reflection on Quality Assurance System of Higher Vocational Education under Big Data Era

    Directory of Open Access Journals (Sweden)

    Jiang Xinlan

    2015-01-01

    Full Text Available Big data has the features like Volume, Variety, Value and Velocity. Here come the new opportunities and challenges for construction of Chinese quality assurance system of higher vocational education under big data era. There are problems in current quality assurance system of higher vocational education, such as imperfect main body, non-formation of internally and externally incorporated quality assurance system, non-scientific security standard and insufficiency in security investment. The construction of higher vocational education under big data era requires a change in the idea of quality assurance system construction to realize the multiple main bodies and multiple layers development trend for educational quality assurance system, and strengthen the construction of information platform for quality assurance system.

  8. Software quality assurance - seven years experience

    International Nuclear Information System (INIS)

    Malsbury, J.A.

    1987-01-01

    This paper describes seven years experience with software quality assurance at PPPL. It covers the early attempts of 1980 and 1981 to establish software quality assurance; the first attempt of 1982 to develop a complete software quality assurance plan; the significant modifications of this plan in 1985; and the future. In addition, the paper describes the role of the Quality Assurance organization within each plan. The scope of this paper is limited to discussions of the software development procedures used in the seven year period. Other software quality topics, such as configuration control or problem identification and resolution, are not discussed

  9. Office of Geologic Repositories quality assurance plan for high-level radioactive waste repositories

    International Nuclear Information System (INIS)

    1986-08-01

    This document sets forth geologic repository program-wide quality assurance program requirements and defines management's quality assurance responsibilities for the Office of Geologic Repositories and its projects. (LM)

  10. The successful Chief Executive Officer understands quality assurance

    International Nuclear Information System (INIS)

    Hedges, D.

    1984-01-01

    The successful Chief Executive Officer (CEO) will have recognized the benefits of, and have implemented, a total quality assurance program. The quality assurance program will be adequately defined in policies and procedures such that managers and supervisors of each organizational element understand their primary and supporting roles in carrying out an effective quality assurance program. The traditional practice of having all quality assurance activities reside in a quality assurance organization will have been cast aside. Instead, the quality assurance activities necessary to achieve and assure the quality of the desired end product will have been defined and assigned to responsible organization elements. The quality assurance organization's primary role will be to define the total quality assurance program, insure that the achieving and assuring functions are assigned in policies and procedures, conduct training necessary to have management and supervisors understand the total quality assurance program, measure the effectiveness of the program and feedback measurement data for improvements in the program. The successful CEO will have implemented a quality assurance program that provides for a graded approach for application of the program based upon the importance of the intended use of the product or service. The successful CEO will rely heavily on the scheduled progress reports and assessments to measure the pulse of his organization's successes and improvement needs. This paper will describe suggested approaches for the Quality Assurance Manager to implement a quality assurance program which results in his corporation's CEO being a supporter of and a driving force in the implementation of the quality assurance program

  11. Thoughts on Internal and External Quality Assurance

    Science.gov (United States)

    Zhang, Jianxin

    2012-01-01

    Quality assurance of higher education is made up of two parts: internal quality assurance (IQA) and external quality assurance (EQA). Both belong to a union of the coexistence and balance of yin and yang. But in reality there exists a paradox of "confusion of quality assurance (QA) subject consciousness, singularity of social QA and lack of QA…

  12. Quality Assurance--Best Practices for Assessing Online Programs

    Science.gov (United States)

    Wang, Qi

    2006-01-01

    Educators have long sought to define quality in education. With the proliferation of distance education and online learning powered by the Internet, the tasks required to assess the quality of online programs become even more challenging. To assist educators and institutions in search of quality assurance methods to continuously improve their…

  13. Code on the safety of nuclear power plants: Quality assurance

    International Nuclear Information System (INIS)

    1988-01-01

    This revised Code provides the principles and objectives for the establishment and implementation of quality assurance programmes applied to both the overall and each of the constituent activities associated with a nuclear power plant project. The quality assurance principles enumerated in the present Code can be usefully applied to nuclear facilities other than nuclear power plants. The quality assurance programme encompasses: (1) the activities that are necessary to achieve the appropriate quality of the respective item or service; and (2) the activities that are necessary for verifying that the required quality is achieved and that objective evidence is produced to that effect. Quality assurance is an essential aspect of good management and the quality assurance programme is the main management tool for a disciplined approach to all activities affecting quality, including, where appropriate, verification that each task has been satisfactorily performed and that necessary corrective actions have been implemented. The principles and objectives provided by the Code are applicable by all those responsible for the nuclear power plant, by plant designers, suppliers, architect-engineers, plant constructors, plant operators and other organizations participating in activities affecting quality. The Code is a revision of the previous Code of Practice (1978) on the same subject of interest to regulatory bodies and experts in quality assurance for design, siting and operation of nuclear power plants. Contents: Definitions; 1. Introduction; 2. Quality assurance programmes; 3. Organization; 4. Document control; 5. Design control; 6. Procurement control; 7. Control of items; 8. Process control; 9. Inspection and test control; 10. Non-conformance control; 11. Corrective actions; 12, Records; 13. Audits

  14. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    International Nuclear Information System (INIS)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung

    2014-01-01

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently

  15. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently.

  16. Rapid quality assurance with requirements smells

    OpenAIRE

    Femmer, Henning; Méndez Fernández, Daniel; Wagner, Stefan; Eder, Sebastian

    2016-01-01

    Context: Bad requirements quality can cause expensive consequences during the software development lifecycle, especially if iterations are long and feedback comes late. Objectives: We aim at a light-weight static requirements analysis approach that allows for rapid checks immediately when requirements are written down. Method: We transfer the concept of code smells to Requirements Engineering as Requirements Smells. To evaluate the benefits and limitations, we define Requirements Smells, real...

  17. Software Quality Assurance Audits Guidebooks

    Science.gov (United States)

    1990-01-01

    The growth in cost and importance of software to NASA has caused NASA to address the improvement of software development across the agency. One of the products of this program is a series of guidebooks that define a NASA concept of the assurance processes that are used in software development. The Software Assurance Guidebook, NASA-GB-A201, issued in September, 1989, provides an overall picture of the NASA concepts and practices in software assurance. Second level guidebooks focus on specific activities that fall within the software assurance discipline, and provide more detailed information for the manager and/or practitioner. This is the second level Software Quality Assurance Audits Guidebook that describes software quality assurance audits in a way that is compatible with practices at NASA Centers.

  18. Quality assurance in the course of fabrication of LWR fuel

    International Nuclear Information System (INIS)

    Dressler, G.; Perry, J.A.

    1982-01-01

    A high quality level of LWR fuel elements can only be assured by a system of Quality Assurance measures purposefully designed, balanced, and appropriately applied. This includes application of and the appropriate balance between both system and product oriented measures. A prerequisite to the establishment of these measures is a precise analysis of the various influences of the individual process steps on the quality characteristics of the starting materials, semi-finished and finished products. In addition, these characteristics require classification criteria relative to their significance. The described classification is used to establish sampling plans and to disposition non-conformances. The EXXON Nuclear Quality Assurance system which is based on these principles is described and illustrated with some examples. (orig.)

  19. Hanford analytical services quality assurance plan. Revision 1

    International Nuclear Information System (INIS)

    1995-02-01

    This document, the Hanford Analytical Services Quality Assurance Plan (HASQAP), is issued by the U.S. Department of Energy, Richland Operations Office (RL). The HASQAP establishes quality requirements in response to U.S. Department of Energy (DOE) Order 5700.6C, Quality Assurance (10 CFR 830.120, open-quotes Quality Assurance Requirementsclose quotes). The HASQAP is designed to meet the needs of the RL for controlling the of analytical chemistry services provided by laboratory operations. The HASQAP is issued through the Analytical Services Branch of the Waste Management Division. The Analytical Services Branch is designated by the RL as having the responsibility for oversight management of laboratory operations under the Waste Management Division. The laboratories conduct sample analyses under several regulatory statutes, such as the Clean Air Act and the Clean Water Act. Sample analysis in support of the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) is a major role of the laboratory operations

  20. 40 CFR 160.35 - Quality assurance unit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Quality assurance unit. 160.35 Section... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for monitoring each study to assure...

  1. Plutonium stabilization and handling quality assurance program plan

    International Nuclear Information System (INIS)

    Weiss, E.V.

    1998-01-01

    This Quality Assurance Program Plan (QAPP) identifies project quality assurance requirements for all contractors involved in the planning and execution of Hanford Site activities for design, procurement, construction, testing and inspection for Project W-460, Plutonium Stabilization and Handling. The project encompasses procurement and installation of a Stabilization and Packaging System (SPS) to oxidize and package for long term storage remaining plutonium-bearing special nuclear materials currently in inventory at the Plutonium Finishing Plant (PFP), and modification of vault equipment to allow storage of resulting packages of stabilized SNM

  2. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  3. Quality assurance in central nuclear power plant control systems. (Status report containing proposed enhancements for KTA rules)

    International Nuclear Information System (INIS)

    Gossner, S.

    1985-01-01

    All enterprises investigated observe the requirements laid down in KTA 1401. In most cases, the quality assurance systems and measures applied even go beyond the requirements of KTA 1401, especially in those enterprises working primarily for export and having to meet foreign quality assurance standards. Quality assurance measures in these enterprises are based primarily on 10 CFR 50, App.B and related rules and standards (e.g. ANSI N 54.2; NUREG 75/087). Internal quality assurance in these enterprises is organized on the basis of graphic flow diagrams which are even presented in the quality assurance manuals. These flow diagrams, in contrast to the German KTA rules, meet the international standards for quality assurance. KTA 1401 requirements not sufficiently met are, e.g. the operator audits with plant producers and unit and equipment producer audits with component producers. The report presents hints for improvements of the quality assurance concept in control systems engineering. (orig./HP) [de

  4. Quality assurance of nuclear fuel

    International Nuclear Information System (INIS)

    1994-01-01

    The guide presents the quality assurance requirements to be completed with in the procurement, design, manufacture, transport, handling and operation of the nuclear fuel. The guide also applies to the procurement of the control rods and the shield elements to be placed in the reactor. The guide is mainly aimed for the licensee responsible for the procurement and operation of fuel, for the fuel designer and manufacturer and for other organizations whose activities affect fuel quality, the safety of fuel transport, storage and operation. (2 refs.)

  5. Quality assurance program manual for nuclear power plants. Volume I. Policies

    International Nuclear Information System (INIS)

    1976-01-01

    The Consumers Power Company Quality Assurance Program Manual for Nuclear Power Plants consists of policies and procedures which comply with current NRC regulatory requirements and industry codes and standards in effect during the design, procurement, construction, testing, operation, refueling, maintenance, repair and modification activities associated with nuclear power plants. Specific NRC and industry documents that contain the requirements, including the issue dates in effect, are identified in each nuclear power plant's Safety Analysis Report. The requirements established by these documents form the basis for the Consumer Power Quality Assurance Program, which is implemented to control those structures, systems, components and operational safety actions listed in each nuclear power plant's Quality List (Q-List). As additional and revised requirements are issued by the NRC and professional organizations involved in nuclear activities, they will be reviewed for their impact on this manual, and changes will be made where considered necessary. CP Co 1--Consumers Power Company QA Program Topical Report is Volume I of this manual and contains Quality Assurance Program Policies applicable during all phases of nuclear power plant design, construction and operation

  6. Managerial attitude toward quality assurance

    International Nuclear Information System (INIS)

    Kirschenmann, H.J.

    1983-01-01

    This paper will present what relationships exist between the attitude toward quality assurance and the variables of training and experience on the part of managers within the nuclear power industry. Managerial attitude toward quality assurance was measured via questionnaires submitted to managers within architect-engineering, nuclear steam supplier, and constructor firms throughout the United States. The data from the completed questionnaires were statistically analyzed using the chi-square test and conclusions were drawn. Additional study results related to major factors for positive and negative attitudes toward quality assurance will be presented

  7. Internal Quality Assurance--Enhancing Quality Culture. ENQA Workshop Report 16

    Science.gov (United States)

    ENQA (European Association for Quality Assurance in Higher Education), 2010

    2010-01-01

    The European Association for Quality Assurance in Higher Education (ENQA), in cooperation with the Quality Assurance Agency (QAA, UK), organised a seminar on theme "Internal Quality Assurance--Enhancing quality culture" which was held on 8-9 June, 2010 in London, United Kingdom. The seminar marked the fourth annual meeting of the ENQA…

  8. Quality assurance measures for spent fuel shipping and storage containers

    International Nuclear Information System (INIS)

    Droste, B.; Roedel, R.

    1987-01-01

    Quality assurance measures are to be applied in production and operation to ensure the approved fuel-element-container design specifications. The authors concentrate on the official regulations pertaining to the application of a quality assurance system, on the compliance with design specifications ensured by certified manufacturing tests and in-service inspections. For nodular-cast-iron container bodies, the authors demonstrate the procedure by presenting the contents of the materials data sheet characterizing the material, and the production and test sequence plan for container casting. In addition, they state the quality assurance requirements for interim-storage containers which transgress those stipulated for shipping containers. (orig.) [de

  9. Concepts of nuclear quality assurance

    International Nuclear Information System (INIS)

    Randers, G.; Morris, P.A.; Pomeroy, D.

    1976-01-01

    While the safety record of the nuclear industry continues to be excellent, the forced outage rates for recent years continue to be 15% or more. Quality assurance, therefore, needs to be applied not only to nuclear safety matters, but to the goals of increased productivity and reduced construction and operating costs. Broadening the application of the general concept of quality assurance in this way leads to the introduction of reliability technology. The total activity might better be called reliability assurance. That effective quality assurance systems do pay off is described by examples from the utility industry, from a manufacturer of instruments and systems and from the experience of Westinghouse Electric Company's manufacturing divisions. The special situation of applying quality assurance to nuclear fuel is discussed. Problems include the lack of a fully developed regulatory policy in this area, incomplete understanding of the mechanism for pellet-clad interaction failures, incomplete access to manufacturers design and process information, inability to make desirable changes on a timely basis and inadequate feedback of irradiation experience. (author)

  10. Quality management and quality assurance

    International Nuclear Information System (INIS)

    Pieroni, N.

    1991-01-01

    The main common difficulties are presented found in the implementation of effective Quality Management and Quality Assurance Programmes, based on the recommendations of the IAEA International Nuclear Safety Advisory Group, the information collected by the IAEA experts participating in its meetings, and the results of the IAEA Operational Safety Review Team missions. The difficulties were identified in several areas. The most relevant root causes can be characterized as lack of understanding of quality principles and difficulty in implementation by the responsible management. The IAEA programme is described attempting to provide advice and support in the implementation of an effective quality programme through a number of activities including: preparation of practical guidelines, training programmes for management personnel, assistance in building up qualified manpower, and promoting the quest for excellence through the exchange of experience in the implementation of effective Quality Management and Quality Assurance Programmes in nuclear power plants with good performance records. (Z.S.)

  11. Design quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-07-01

    This Standard contains the requirements for the quality assurance program applicable to the design phase of a nuclear plant, and is applicable to the design of safety-related equipment, systems, and structures, as identified by the owner. 1 fig.

  12. Design quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1986-07-01

    This Standard contains the requirements for the quality assurance program applicable to the design phase of a nuclear plant, and is applicable to the design of safety-related equipment, systems, and structures, as identified by the owner. 1 fig

  13. Modernization of software quality assurance

    Science.gov (United States)

    Bhaumik, Gokul

    1988-01-01

    The customers satisfaction depends not only on functional performance, it also depends on the quality characteristics of the software products. An examination of this quality aspect of software products will provide a clear, well defined framework for quality assurance functions, which improve the life-cycle activities of software development. Software developers must be aware of the following aspects which have been expressed by many quality experts: quality cannot be added on; the level of quality built into a program is a function of the quality attributes employed during the development process; and finally, quality must be managed. These concepts have guided our development of the following definition for a Software Quality Assurance function: Software Quality Assurance is a formal, planned approach of actions designed to evaluate the degree of an identifiable set of quality attributes present in all software systems and their products. This paper is an explanation of how this definition was developed and how it is used.

  14. Guidelines for the introduction of a quality assurance programme in a diagnostic imaging department

    International Nuclear Information System (INIS)

    1992-01-01

    Radiographers, whether they practice in the National Health Service (NHS) or other health care systems, always strive to deliver a high quality service for their patients. The profession and its members work hard to maintain and improve standards of patient care and technical accuracy. Why then does the College of Radiographers feel it necessary to publish Quality Assurance Guidelines? The answer lies in the greater awareness that the best possible service provision requires every part of the whole service to be performing as well as it possibly can. To be sure these individual parts are achieving this goal requires that we set standards for them and monitor and reassess them regularly. The quality of an individual's or a system's performance cannot be defined in absolute terms, although this is how many people would see it. There are too many variables, some of which cannot be controlled. Instead, we must define quality as the ability to perform the required task to set standards, given the prevailing conditions and existing resources. In radiography we can assure quality by being sure that those factors over which we have control are optimised. The College of Radiographers Working Party on Quality Assurance was formed in response to members' concerns about the requirements of professionalism and legislation with regard to quality assurance. Members were confused by the approach to quality management issues, standard setting, monitoring, evaluation and the required record keeping. Work began on a comprehensive publication centred on the quality assurance of radiographic processes. However, the College felt there was danger in following a well trodden path, particularly as the passing months saw the release of a series of related publications from various sources pre-emptying the efforts of the Working Party. Ultimately, the original remit was considered to hold greater promise - a set of guidelines for the quality management of the whole of our service delivery

  15. The development of quality assurance program in Reactor TRIGA PUSPATI (RTP)

    International Nuclear Information System (INIS)

    Rosli Darmawan; Mohd Rizal Mamat; Mohamad Zaid Mohamad; Mohd Ridzuan Abdul Mutalib

    2007-01-01

    One of the trivial issues in the operation of Nuclear Reactor is the safety of the system. Worldwide publicity on a few nuclear accidents as well as the notorious Hiroshima and Nagasaki bombing has always bring about general public fear on anything related to nuclear. IAEA has always emphasized on the assurance of nuclear safety for all nuclear installations and activities. According to the IAEA safety guides, all research reactors are required to implement quality assurance programs to ensure the conduct of operations are in accordance with the safety standards required. This paper discusses the activities carried out toward the establishment of Quality Assurance Program for Reaktor TRIGA PUSPATI (RTP). (Author)

  16. Subsurface quality assurance practices

    International Nuclear Information System (INIS)

    1987-08-01

    This report addresses only the concept of applying Nuclear Quality Assurance (NQA) practices to repository shaft and subsurface design and construction; how NQA will be applied; and the level of detail required in the documentation for construction of a shaft and subsurface repository in contrast to the level of detail required in the documentation for construction of a traditional mine. This study determined that NQA practices are viable, attainable, as well as required. The study identified the appropriate NQA criteria and the repository's major structures, systems, items, and activities to which the criteria are applicable. A QA plan, for design and construction, and a list of documentation, for construction, are presented. 7 refs., 1 fig., 18 tabs

  17. Quality assurance in the procurement, design and manufacture of nuclear fuel assemblies

    International Nuclear Information System (INIS)

    1983-01-01

    This Safety Guide provides requirements and recommendations for quality assurance programmes that are relevant for the unique features of the procurement, design, manufacture, inspection, testing, packaging, shipping, storage, and receiving inspection of fuel assemblies for nuclear power plants. The generic quality assurance requirements of the Code and related Safety Guides are referred to where applicable, and are duplicated in this document where increased emphasis is desirable

  18. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  19. 10 CFR 72.142 - Quality assurance organization.

    Science.gov (United States)

    2010-01-01

    ... activities are performed, the organizational structure for executing the quality assurance program may take... the required authority and organizational freedom. Irrespective of the organizational structure, the... functions of structures, systems, and components which are important to safety. These activities include...

  20. Quality assurance grading guidelines for research and development at DOE facilities

    Energy Technology Data Exchange (ETDEWEB)

    Powell, T.B.; Morris, R.N.

    1993-01-01

    The quality assurance (QA) requirements for the US Department of Energy (DOE) are established in DOE Order 5700.6C. This order is applicable for all DOE departmental elements, management, and maintenance and operating contractors and requires that documented Quality Assurance Programs (QAPs) are prepared at all levels; it has one attachment. The DOE Office of Energy Research (DOE-ER) has issued a standard to ensure implementation of the full intent of this order in the ER community.

  1. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Paras, P.

    1978-01-01

    Quality assurance practices must be followed throughout the entire nuclear medicine process, from the initial decision to perform a particular procedure, through the interpretation and reporting of the results. The various parameters that can be defined and measured in each area must be monitored by quality control tests to assure the excellence of the total nuclear medicine process. The presentation will discuss each of the major areas of nuclear medicine quality control and their interaction as a part of the entire system. Quality control testing results and recommendations for measurements of radioactivity distribution will be described with emphasis on imaging equipment and dose calibrating instrumentation. The role of the health physicist in a quality assurance program will be stressed. (author)

  2. Quality assurance in the manufacture of items for nuclear power plants

    International Nuclear Information System (INIS)

    1981-01-01

    This Safety Guide provides requirements and recommendations related to the establishment and implementation of a quality assurance programme for those organizations involved in the manufacture of items affecting the safety of nuclear power plants. The quality-assurance-related functions of a manufacturer may include activities such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, inspecting, testing, modifying, repairing and maintaining. It is not the aim of the present Guide, which supplements the above-mentioned Code of Practice, to provide rules related to the quality assurance programme for the design of items. Manufacturers that generate designs shall follow the requirements and recommendations contained in the Safety Guide on Quality Assurance in the Design of Nuclear Power Plants (IAEA Safety Series No. 50-SG-QA6). All these publications form part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to land-based stationary thermal neutron power plants. A Provisional List of NUSS Programme Titles will be found at the end of this publication

  3. Underground Test Area Activity Quality Assurance Plan Nevada National Security Site, Nevada. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Krenzien, Susan [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2012-10-01

    This Quality Assurance Plan (QAP) provides the overall quality assurance (QA) requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office (NNSA/NSO) Underground Test Area (UGTA) activities. The requirements in this QAP are consistent with DOE Order 414.1C, Quality Assurance (DOE, 2005); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). NNSA/NSO, or designee, must review this QAP every two years. Changes that do not affect the overall scope or requirements will not require an immediate QAP revision but will be incorporated into the next revision cycle after identification. Section 1.0 describes UGTA objectives, participant responsibilities, and administrative and management quality requirements (i.e., training, records, procurement). Section 1.0 also details data management and computer software requirements. Section 2.0 establishes the requirements to ensure newly collected data are valid, existing data uses are appropriate, and environmental-modeling methods are reliable. Section 3.0 provides feedback loops through assessments and reports to management. Section 4.0 provides the framework for corrective actions. Section 5.0 provides references for this document.

  4. Improving patient safety through quality assurance.

    Science.gov (United States)

    Raab, Stephen S

    2006-05-01

    Anatomic pathology laboratories use several quality assurance tools to detect errors and to improve patient safety. To review some of the anatomic pathology laboratory patient safety quality assurance practices. Different standards and measures in anatomic pathology quality assurance and patient safety were reviewed. Frequency of anatomic pathology laboratory error, variability in the use of specific quality assurance practices, and use of data for error reduction initiatives. Anatomic pathology error frequencies vary according to the detection method used. Based on secondary review, a College of American Pathologists Q-Probes study showed that the mean laboratory error frequency was 6.7%. A College of American Pathologists Q-Tracks study measuring frozen section discrepancy found that laboratories improved the longer they monitored and shared data. There is a lack of standardization across laboratories even for governmentally mandated quality assurance practices, such as cytologic-histologic correlation. The National Institutes of Health funded a consortium of laboratories to benchmark laboratory error frequencies, perform root cause analysis, and design error reduction initiatives, using quality assurance data. Based on the cytologic-histologic correlation process, these laboratories found an aggregate nongynecologic error frequency of 10.8%. Based on gynecologic error data, the laboratory at my institution used Toyota production system processes to lower gynecologic error frequencies and to improve Papanicolaou test metrics. Laboratory quality assurance practices have been used to track error rates, and laboratories are starting to use these data for error reduction initiatives.

  5. Core components of a comprehensive quality assurance program in anatomic pathology.

    Science.gov (United States)

    Nakhleh, Raouf E

    2009-11-01

    In this article the core components of a comprehensive quality assurance and improvement plan are outlined. Quality anatomic pathology work comes with focus on accurate, timely, and complete reports. A commitment to continuous quality improvement and a systems approach with a persistent effort helps to achieve this end. Departments should have a quality assurance and improvement plan that includes a risk assessment of real and potential problems facing the laboratory. The plan should also list the individuals responsible for carrying out the program with adequate resources, a defined timetable, and annual assessment for progress and future directions. Quality assurance monitors should address regulatory requirements and be organized by laboratory division (surgical pathology, cytology, etc) as well as 5 segments (preanalytic, analytic, postanalytic phases of the test cycle, turn-around-time, and customer satisfaction). Quality assurance data can also be used to evaluate individual pathologists using multiple parameters with peer group comparison.

  6. A conceptual competitive intelligence quality assurance model

    Directory of Open Access Journals (Sweden)

    Tshilidzi Eric Nenzhelele

    2015-12-01

    Full Text Available Competitive Intelligence (CI improves the quality of product and service, decision-making and it improves quality of life. However, it has been established that decision makers are not happy about the quality of CI. This is because enterprises fail in quality assurance of CI. It has been concluded that most enterprises are clueless concerning CI quality assurance. Studies that previously attempted to resolve CI quality problem were limited in scope and focused too much on the quality of information than the overall CI quality. The purpose of this study is to propose a conceptual CI quality assurance model which will help in quality assurance of CI. The research was qualitative in nature and used content analysis.

  7. [Quality assurance in colorectal cancer in Europe AD 2011].

    Science.gov (United States)

    Mroczkowski, P; Hac, S; Lippert, H; Kube, R

    2013-12-01

    Malignant tumours are the second largest cause of death in Europe. Colorectal cancer takes second place within this group and is responsible for every eighth tumour-related death. Surgical quality assurance requires a prospective observational study, any different type of study is not possible. A complete recording of all treated patients is a prerequisite for quality assurance. Currently, there are quality assurance programmes in Sweden, Norway, Denmark, Great Britain, Spain, Belgium, the Netherlands as well as the multinational study for patients from Germany, Poland and Italy. These projects deliver comprehensive information regarding the treatment of colorectal cancer. However, this information is deeply rooted in the organisation of the health-care system in the given country and is not easily transferable into international settings. Also, an interpretation of the collected data is often possible only within the given health-care system. First, unified initial diagnostics is a prerequisite for quality assurance -  for the local extent and exclusion / confirmation of distant metastases. Until these criteria are unified, any comparison is limited, including a comparison of survival. Second, quality-of-life is not recorded in any of the current projects. Third, the main focus of a quality assurance project must be on therapy-dependent factors. The most sensible method of quality control remains within the connection of preoperative diagnostics (estimate of a best-case scenario), the surgical technique (the actual result) and a standardised pathological examination (evaluation of the actual result). These parameters can be recorded and compared within a quality assurance project regardless of the limitations of the national health-care systems. There is no alternative to a unified diagnostics model and unified histopathological evaluation, a complete picture of treatment quality is also not possible without systematic analysis of the quality of life.

  8. [Quality assurance in interventional cardiology].

    Science.gov (United States)

    Gülker, H

    2009-10-01

    Quality assurance in clinical studies aiming at approval of pharmaceutical products is submitted to strict rules, controls and auditing regulations. Comparative instruments to ensure quality in diagnostic and therapeutic procedures are not available in interventional cardiology, likewise in other fields of cardiovascular medicine. Quality assurance simply consists of "quality registers" with basic data not externally controlled. Based on the experiences of clinical studies and their long history of standardization it is assumed that these data may be severely flawed thus being inappropriate to set standards for diagnostic and therapeutic strategies. The precondition for quality assurance are quality data. In invasive coronary angiography and intervention medical indications, the decision making process interventional versus surgical revascularization, technical performance and after - care are essential aspects affecting quality of diagnostics and therapy. Quality data are externally controlled data. To collect quality data an appropriate infrastructure is a necessary precondition which is not existent. For an appropriate infrastructure investments have to be done both to build up as well as to sustain the necessary preconditions. As long as there are no infrastructure and no investments there will be no "quality data". There exist simply registers of data which are not proved to be a basis for significant assurance and enhancement in quality in interventional coronary cardiology. Georg Thieme Verlag KG Stuttgart, New York.

  9. Office of Storage and Transportation Systems quality assurance directive

    International Nuclear Information System (INIS)

    1986-10-01

    This Directive provides policy guidance, defines organizational authorities and responsibilities for quality assurance (QA) and establishes minimum acceptable requirements for assuring the quality of all programs under the overall direction of the OSTS. This directive provides guidance for preparation of subordinate QA documents (e.g., QA plans, procedures) for the major Office of Storage and Transportation Systems programs that support DOE licensing and/or certification objectives. In turn, those highly specific QA documents will amplify the general guidance presented in this Directive

  10. Underground Test Area Activity Quality Assurance Plan Nevada National Security Site, Nevada. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Krenzien, Susan [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States); Farnham, Irene [Navarro-Intera, LLC (N-I), Las Vegas, NV (United States)

    2015-06-01

    This Quality Assurance Plan (QAP) provides the overall quality assurance (QA) requirements and general quality practices to be applied to the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) Underground Test Area (UGTA) activities. The requirements in this QAP are consistent with DOE Order 414.1D, Change 1, Quality Assurance (DOE, 2013a); U.S. Environmental Protection Agency (EPA) Guidance for Quality Assurance Project Plans for Modeling (EPA, 2002); and EPA Guidance on the Development, Evaluation, and Application of Environmental Models (EPA, 2009). If a participant’s requirement document differs from this QAP, the stricter requirement will take precedence. NNSA/NFO, or designee, must review this QAP every two years. Changes that do not affect the overall scope or requirements will not require an immediate QAP revision but will be incorporated into the next revision cycle after identification. Section 1.0 describes UGTA objectives, participant responsibilities, and administrative and management quality requirements (i.e., training, records, procurement). Section 1.0 also details data management and computer software requirements. Section 2.0 establishes the requirements to ensure newly collected data are valid, existing data uses are appropriate, and environmental-modeling methods are reliable. Section 3.0 provides feedback loops through assessments and reports to management. Section 4.0 provides the framework for corrective actions. Section 5.0 provides references for this document.

  11. Quality assurance program. Topical report, GIBSAR-7

    International Nuclear Information System (INIS)

    1975-09-01

    The quality assurance program developed by Gibbs and Hill to satisfy the requirement that design, engineering, procurement, fabrication, and construction activities for nuclear power plants are performed in accordance with applicable codes, standards, and regulatory criteria is outlined. The program was developed to conform to the criteria of Appendix B to 10 CFR Part 50 and is presented in such a manner that each of the 18 criteria are individually set forth. The Gibbs and Hill program, implemented by the procedures of the corporate Quality Assurance Manual also follows the guidelines of the NRC Gray Book, WASH 1283, Rev. 1, May 24, 1974, and Green Book, WASH 1309, May 10, 1974. (auth)

  12. Material quality assurance risk assessment : [summary].

    Science.gov (United States)

    2013-01-01

    With the shift from quality control (QC) of materials and placement techniques : to quality assurance (QA) and acceptance over the years, the role of the Office : of Materials Technology (OMT) has been shifting towards assurance of : material quality...

  13. 48 CFR 12.208 - Contract quality assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract quality assurance... Items 12.208 Contract quality assurance. Contracts for commercial items shall rely on contractors' existing quality assurance systems as a substitute for Government inspection and testing before tender for...

  14. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-06-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  15. Report on the activities of the ASME-NQA Committee Working Group on Quality Assurance Requirements for Research and Development, April 1990 to August 1991

    Energy Technology Data Exchange (ETDEWEB)

    Dronkers, J.J.

    1991-09-01

    This report transmits to the public eye the activities of the American Society of Mechanical Engineers-Nuclear Quality Assurance (ASME-NQA) Committee Working Group on Quality Assurance Requirements for Research and Development. The appendix lists the members of this group as of August 1991. The report covers a period of 17 months. The working group met eight times in this period, and much intellectual ground was traversed. There was seldom agreement on the nature of the task, but there was no doubt as to its urgency. The task was how to adapt the nuclear quality assurance standard, the NQA-1, to research and development work. 1 fig., 7 tabs.

  16. Quality assurance. 6. ed.

    International Nuclear Information System (INIS)

    Masing, W.

    1979-01-01

    Brief introduction to the quality sector. After some explanations of the terms of quality, feature, and defect, the article discusses the planning of quality and testing, industrial metrology, the test risk, quality assurance, quality enhancement, quality cost, and organisational problems. (RW) [de

  17. Roles of the operator and the safety services in nuclear power plant quality assurance

    International Nuclear Information System (INIS)

    Widmer, M.; Perrot, J.

    1985-01-01

    With regard to the operation of nuclear power plants, Electricite de France formally recognized in 1973 that it was necessary for safety reasons and economically acceptable to adopt organizational principles of quality assurance that would be applicable both to its own activities and to those of its suppliers. Generally speaking, the form and spirit of the quality assurance programme chosen is based largely on the Code of Practice No. 50-C-QA. In particular, the programme focuses on the flexible character of quality assurance requirements and stresses that in the final analysis product quality depends above all on those to whom the project has been assigned, because it is they who are responsible for meeting the quality objectives set. Ten years of experience with the suppliers of Electricite de France has shown that these suppliers, after some initial difficulty, have been able to adapt the application of quality assurance so as to achieve satisfactory quality as regards both safety and availability. In the case of the French standard nuclear power plants, quality assurance is particularly important thanks to the traceability which it affords and to the allowance for corrective measures which it demands. The safety services normally take action related to quality assurance in three ways: through regulation, the analysis of measures to assure plant safety, and plant supervision. As regards regulation, an order has just been published relating to design, construction and operational quality in base-load nuclear power plants. The requirements laid down in this document incorporate the recommendations of the IAEA Code on quality assurance. (author)

  18. Integrating quality assurance and research and development

    International Nuclear Information System (INIS)

    Dronkers, J.J.

    1985-01-01

    Quality assurance programs cannot be transferred from one organization to another without attention to existing cultures and traditions. Introduction of quality assurance programs constitutes a significant change and represents a significant impact on the organizational structure and operational mode. Quality assurance professionals are change agents, but do not know how to be effective ones. Quality assurance as a body of knowledge and experience can only become accepted when its practitioners become familiar with their role as change agents. 8 references

  19. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    Groth, S.; Meghzifene, A.; Tatsuzaki, H.; Levin, V.; Izewska, J.

    2001-01-01

    Quality assurance in the management of a patient receiving radiation therapy and the role of the radiation oncologist and medical physicist in this process is described. The constraints on available personnel are recognised and the need for further education resources and IAEA activities in education for both groups described. IAEA activities in the clinical and dosimetric aspects and the resultant publications and education have contributed to a culture of quality assurance. (author)

  20. The contribution of quality assurance to safety and reliability in nuclear power plants

    International Nuclear Information System (INIS)

    Raisic, N.

    1978-01-01

    The potential contribution of quality assurance to nuclear power plant safety and reliability is analysed. An attempt is made to establish a relationship between quality and reliability. The reliability may be expressed in quantitative terms as ''the probability that an item will perform a required function for a stated period of time''. Quality, however, cannot be expressed in simple quantitative terms but only as a set of required properties which an item should have for a specific application. The achievement of quality and additional reliability objectives is a task of project activities such as design, construction, installation, operation, etc. The elements of a quality assurance system and its functions in nuclear power projects are presented in some detail. Confidence in plant quality, which should be a basis for the regulatory body issuing the construction permit or operation licence, should be based on the capability of quality assurance activities to prevent errors and correct deficiencies in nuclear power plants. An analysis is made of those errors in plant design, manufacture, construction and operation which contribute most frequently to plant outages. It is concluded that these errors can be avoided or corrected by strict adherence to quality assurance principles and by the efficient functioning of quality assurance systems. In fact, quality assurance may be considered an effective defence against common cause failures originating in errors in the design, manufacture, installation or operation of a nuclear power plant

  1. Relevant aspects of a quality assurance program applied to a nuclear power plant operation

    International Nuclear Information System (INIS)

    Fernandez, J.C.

    1987-01-01

    The purpose of this work was to enumerate the most relevant subjects to be taken into account for the elaboration of a Quality Assurance Program aimed to regulate a nuclear power plant operation. At first, it was necessary to point out the relevance that implies the presence of a group of personnel, experienced in quality assurance with enough knowledge on the technical and organizing aspects of the plant. Other aspect to be taken into account was the contemplation of the international requirements, through the International Atomic Energy Agency and of the national requirements that each country had set up by the corresponding regulating agencies. These organizations pointed out the minimum rules that must be followed for the adequate and efficient execution of a program. The Quality Assurance Manual and the program and work procedures constituted the Quality Assurance Program which must be checked as regards its fulfillment by auditors and quality assurance supervisions. (Author)

  2. An approach to applying quality assurance to nuclear fuel waste disposal

    International Nuclear Information System (INIS)

    Cooper, R.B.; Abel, R.

    1996-12-01

    An approach to developing and applying a quality assurance program for a nuclear fuel waste disposal facility is described. The proposed program would be based on N286-series standards used for quality assurance programs in nuclear power plants, and would cover all aspects of work across all stages of the project, from initial feasibility studies to final closure of the vault. A quality assurance manual describing the overall quality assurance program and its elements would be prepared at the outset. Planning requirements of the quality assurance program would be addressed in a comprehensive plan for the project. Like the QA manual, this plan would be prepared at the outset of the project and updated at each stage. Particular attention would be given to incorporating the observational approach in procedures for underground engineering, where the ability to adapt designs and mining techniques to changing ground conditions would be essential. Quality verification requirements would be addressed through design reviews, peer reviews, inspections and surveillance, equipment calibration and laboratory analysis checks, and testing programs. Regular audits and program reviews would help to assess the state of implementation, degree of conformance to standards, and effectiveness of the quality assurance program. Audits would be particularly useful in assessing the quality systems of contractors and suppliers, and in verifying the completion of work at the end of stages. Since a nuclear fuel waste disposal project would span a period of about 90 years, a key function of the quality assurance program would be to ensure the continuity of knowledge and the transfer of experience from one stage to another This would be achieved by maintaining a records management system throughout the life of the project, by ensuring that work procedures were documented and kept current with new technologies and practices, and by instituting training programs that made use of experience gained

  3. Quality Assurance in the Presence of Variability

    Science.gov (United States)

    Lauenroth, Kim; Metzger, Andreas; Pohl, Klaus

    Software Product Line Engineering (SPLE) is a reuse-driven development paradigm that has been applied successfully in information system engineering and other domains. Quality assurance of the reusable artifacts of the product line (e.g. requirements, design, and code artifacts) is essential for successful product line engineering. As those artifacts are reused in several products, a defect in a reusable artifact can affect several products of the product line. A central challenge for quality assurance in product line engineering is how to consider product line variability. Since the reusable artifacts contain variability, quality assurance techniques from single-system engineering cannot directly be applied to those artifacts. Therefore, different strategies and techniques have been developed for quality assurance in the presence of variability. In this chapter, we describe those strategies and discuss in more detail one of those strategies, the so called comprehensive strategy. The comprehensive strategy aims at checking the quality of all possible products of the product line and thus offers the highest benefits, since it is able to uncover defects in all possible products of the product line. However, the central challenge for applying the comprehensive strategy is the complexity that results from the product line variability and the large number of potential products of a product line. In this chapter, we present one concrete technique that we have developed to implement the comprehensive strategy that addresses this challenge. The technique is based on model checking technology and allows for a comprehensive verification of domain artifacts against temporal logic properties.

  4. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  5. Progress in France of the standardization of multi-level quality assurance

    International Nuclear Information System (INIS)

    Debout, E.

    1982-01-01

    Quality assurance has evolved in a steady but somewhat haphazard manner in various industries, each of which has drawn up its own standards. Examples of this are the armaments industry under the auspices of NATO, nuclear energy (IAEA guides), the French aerospace industries and the Industrial Monitoring Service for Armaments in France. For the sake of both the supplier companies and the customers, these differing and sometimes incompatible requirements should be brought into line. At the instigation of the French Association for Industrial Quality Control (AFCIQ), the French Association for Standardization (AFNOR) is therefore in the process of publishing a series of documents on quality management and assurance. For its part, the International Organization for Standardization (ISO) has set up a committee (TC 176) to standardize quality assurance. The different documents provide for various levels of quality assurance, the compatibility of which will have to be closely monitored. (author)

  6. Report of AAPM TG 135: quality assurance for robotic radiosurgery.

    Science.gov (United States)

    Dieterich, Sonja; Cavedon, Carlo; Chuang, Cynthia F; Cohen, Alan B; Garrett, Jeffrey A; Lee, Charles L; Lowenstein, Jessica R; d'Souza, Maximian F; Taylor, David D; Wu, Xiaodong; Yu, Cheng

    2011-06-01

    The task group (TG) for quality assurance for robotic radiosurgery was formed by the American Association of Physicists in Medicine's Science Council under the direction of the Radiation Therapy Committee and the Quality Assurance (QA) Subcommittee. The task group (TG-135) had three main charges: (1) To make recommendations on a code of practice for Robotic Radiosurgery QA; (2) To make recommendations on quality assurance and dosimetric verification techniques, especially in regard to real-time respiratory motion tracking software; (3) To make recommendations on issues which require further research and development. This report provides a general functional overview of the only clinically implemented robotic radiosurgery device, the CyberKnife. This report includes sections on device components and their individual component QA recommendations, followed by a section on the QA requirements for integrated systems. Examples of checklists for daily, monthly, annual, and upgrade QA are given as guidance for medical physicists. Areas in which QA procedures are still under development are discussed.

  7. Reinforcing Quality Assurance in Romanian Higher Education

    Directory of Open Access Journals (Sweden)

    Ana-Maria Dima

    2010-07-01

    Full Text Available Since 1993, the quality assurance system in Romania has gained considerable experience. This experience was recently recognized in 2008 by the ENQA: European Association for Quality Assurance in Higher Education through the admission of ARACIS as a full member of EQAR: the European Quality Assurance Register. The Board of ENQA agreed to grant ARACIS’s full membership of ENQA for five years from 2 June 2009. This article explores the benefits of membership for the Romanian Agency for Quality Assurance in Higher Education – ARACIS, comparing to other regional and global quality assurance agencies networks. The common features and differences between ARACIS and other European agencies are questioned through the frameworks of ENQA and INQAAHE as a case study.

  8. Educational Auditing and Quality Assurance. Occasional Paper No. 4.

    Science.gov (United States)

    Conner, James E.; Lessinger, Leon M.

    This paper considers how to respond to new requirements for adequate disclosure of the schools' performance to the public. It proposes the use of three powerful constructs--quality control, quality assurance, and an independent educational accomplishment audit (IEAA). The essential elements of quality control are agreeing on and specifying desired…

  9. Clinical quality assurance in radiation oncology

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    A quality assurance program in radiation oncology monitors and evaluates any departmental functions which have an impact on patient outcome. The ultimate purpose of the program is to maximize health benefit to the patient without a corresponding increase in risk. The foundation of the program should be the credo: at least do no harm, usually do some good and ideally realize the greatest good. The steep dose response relationships for tumor control and complications require a high degree of accuracy and precision throughout the entire process of radiation therapy. It has been shown that failure to control local disease with radiation may result in decreased survival and may increase the cost of care by a factor of 3. Therefore, a comprehensive quality assurance program which seeks to optimize dose delivery and which encompasses both clinical and physics components, is needed

  10. The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fix, N. J.

    2008-03-12

    Pacific Northwest National Laboratory researchers are working on the Columbia River Protection Supplemental Technologies Project. This project is a U. S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies, and technologies for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Technologies Project staff.

  11. Measurement quality assurance for radioassay laboratories

    Energy Technology Data Exchange (ETDEWEB)

    McCurdy, D.E. [Yankee Atomic Environmental Laboratory, Boston, MA (United States)

    1993-12-31

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, {open_quotes}Measurement Quality Assurance For Radioassay Laboratories.{open_quotes} The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory`s specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations.

  12. Measurement quality assurance for radioassay laboratories

    International Nuclear Information System (INIS)

    McCurdy, D.E.

    1993-01-01

    Until recently, the quality of U.S. radioassay laboratory services has been evaluated by a limited number of governmental measurement assurance programs (MAPs). The major programs have been limited to the U.S. Department of Energy (DOE), the U.S. Environmental Protection Agency (EPA) and the U.S. Nuclear Regulatory Commission (NRC). In 1988, an industry MAP was established for the nuclear power utility industry through the U.S. Council for Energy Awareness/National Institute of Standards and Technology (USCEA/NIST). This program functions as both a MAP for utility laboratories and/or their commercial contractor laboratories, and as a traceability program for the U.S. radioactive source manufacturers and the utility laboratories. Each of these generic MAPs has been initiated and is maintained to serve the specific needs of the sponsoring agency or organization. As a result, there is diversification in their approach, scope, requirements, and degree of traceability to NIST. In 1987, a writing committee was formed under the American National Standards Institute (ANSI) N42.2 committee to develop a standard to serve as the basis document for the creation of a national measurement quality assurance (MQA) program for radioassay laboratories in the U.S. The standard is entitled, open-quotes Measurement Quality Assurance For Radioassay Laboratories.open-quotes The document was developed to serve as a guide for MQA programs maintained for the specialized sectors of the radioassay community, such as bioassay, routine environmental monitoring, environmental restoration and waste management, radiopharmaceuticals, and nuclear facilities. It was the intent of the writing committee to develop a guidance document that could be utilized to establish a laboratory's specific data quality objectives (DQOs) that govern the operational requirements of the radioassay process, including mandated protocols and recommendations

  13. Basic principles of quality assurance

    International Nuclear Information System (INIS)

    Stauffer, M.

    1977-01-01

    After a brief review of the origin of the 'quality concept' and the historical development of quality assurance, questions such as 'what is QA' and 'why is QA so important in nuclear technology' as well as definitions and main requirements of relevant QA codes and standards are presented and discussed. By means of a project realization schematic, tasks, duties, responsibilities, and possible QA organigrammes as well as QA programme and manual requirements are explained and compared. From a QA point of view, it is shown that no basic difference exists between design and production or construction control activities. Special emphasis is layed upon active owner's participation in the implementation of QA programmes for NPP and the advantages offered are described and illustrated by typical examples. (RW) [de

  14. 21 CFR 58.35 - Quality assurance unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Quality assurance unit. 58.35 Section 58.35 Food... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for...

  15. Quality assurance plan for the Objective Supply Capability Adaptive Redesign (OSCAR) project

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, K.A.; Rasch, K.A.; Reid, R.W.

    1996-11-01

    This document establishes the Quality Assurance Plan (QAP) for the National Guard Bureau Objective Supply Capability Adaptive Redesign (OSCAR) project activities under the Oak Ridge National Laboratory (ORNL) management. It defines the requirements and assigns responsibilities for ensuring, with a high degree of confidence, that project objectives will be achieved as planned. The QAP outlined herein is responsive to and meets the Quality Assurance Program standards for the U.S. Department of Energy (DOE), Lockheed Martin Energy Research Corporation and ORNL and the ORNL Computing, Robotics, and Education Directorate (CRE). This document is intended to be in compliance with DOE Order 5700.6C, Quality Assurance Program, and the ORNL Standard Practice Procedure, SPP X-QA-8, Quality Assurance for ORNL Computing Software. This standard allows individual organizations to apply the stated requirements in a flexible manner suitable to the type of activity involved. Section I of this document provides an introduction to the OSCAR project QAP; Sections 2 and 3 describe the specific aspects of quality assurance as applicable to the OSCAR project. Section 4 describes the project approach to risk management. The Risk Management Matrix given in Appendix A is a tool to assess, prioritize, and prevent problems before they occur. Therefore, the matrix will be reviewed and revised on a periodic basis.

  16. Recent Trends in Quality Assurance

    Science.gov (United States)

    Amaral, Alberto; Rosa, Maria Joao

    2010-01-01

    In this paper we present a brief description of the evolution of quality assurance in Europe, paying particular attention to its relationship to the rising loss of trust in higher education institutions. We finalise by analysing the role of the European Commission in the setting up of new quality assurance mechanisms that tend to promote…

  17. Technical position on items and activities in the high-level waste geologic repository program subject to quality assurance requirements

    International Nuclear Information System (INIS)

    Duncan, A.B.; Bilhorn, S.G.; Kennedy, J.E.

    1988-04-01

    This document provides guidance on how to identify items and activities subject to Quality Assurance in the high-level nuclear waste repository program for pre-closure and post-closure phases of the repository. In the pre-closure phase, structures, systems and components essential to the prevention or mitigation of an accident that could result in an off-site radiation dose of 0.5rem or greater are termed ''important to safety''. In the post-closure phase, the barriers which are relied on to meet the containment and isolation requirements are defined as ''important to waste isolation''. These structures, systems, components, and barriers, and the activities related to their characterization, design, construction, and operation are required to meet quality assurance (QA) criteria to provide confidence in the performance of the geologic repository. The list of structures, systems, and components important to safety and engineered barriers important to waste isolation is referred to as the ''Q-List'' and lies within the scope of the QA program. 10 refs

  18. Has quality assurance outlived its usefulness

    International Nuclear Information System (INIS)

    Goldenberg, N.

    1989-01-01

    This paper explores the impact that better management and increased productivity will have on the need for, and role of, quality assurance in the future. The author discusses criticisms of existing quality assurance programs

  19. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  20. Quality assurance of ageing components

    International Nuclear Information System (INIS)

    Novak, W.

    1992-01-01

    Comprehensive and permanent quality assurance on existing plants places very high requirements on measurement and evaluation technology. The necessary preconditions are often not met, however. By means of stocktaking using an external data registration and evaluation system may provide the basis for the assessment of the object and the existing power station instrumentation. After defining the desired scope and standards for the evaluation process, a specific solution may be produced. 5 figs

  1. Quality assurance for image-guided radiotherapy

    International Nuclear Information System (INIS)

    Marinello, Ginette

    2008-01-01

    The topics discussed include, among others, the following: Quality assurance program; Image guided radiotherapy; Commissioning and quality assurance; Check of agreement between visual and displayed scales; quality controls: electronic portal imaging device (EPID), MV-kV and kV-kV, cone-beam CT (CBCT), patient doses. (P.A.)

  2. Quality assurance of operating instructions

    International Nuclear Information System (INIS)

    Asmuss, G.

    1992-01-01

    It is pointed out that the quality assurance at nuclear power stations must be supported by national and international regulations. Quality assurance is explained using the example of the design of a pressurised water reactor. The operating and emergency manuals are discussed and examples for their structure put forward. The significance of updating is emphasised. 15 figs., 19 refs

  3. International Thermonuclear Experimental Reactor U.S. Home Team Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Sowder, W. K.

    1998-10-01

    The International Thermonuclear Experimental Reactor (ITER) project is unique in that the work is divided among an international Joint Central Team and four Home Teams, with the overall responsibility for the quality of activities performed during the project residing with the ITER Director. The ultimate responsibility for the adequacy of work performed on tasks assigned to the U.S. Home Team resides with the U.S. Home Team Leader and the U.S. Department of Energy Office of Fusion Energy (DOE-OFE). This document constitutes the quality assurance plan for the ITER U.S. Home Team. This plan describes the controls exercised by U.S. Home Team management and the Performing Institutions to ensure the quality of tasks performed and the data developed for the Engineering Design Activities assigned to the U.S. Home Team and, in particular, the Research and Development Large Projects (7). This plan addresses the DOE quality assurance requirements of 10 CFR 830.120, "Quality Assurance." The plan also describes U.S. Home Team quality commitments to the ITER Quality Assurance Program. The ITER Quality Assurance Program is based on the principles described in the International Atomic Energy Agency Standard No. 50-C-QA, "Quality Assurance for Safety in Nuclear Power Plants and Other Nuclear Facilities." Each commitment is supported with preferred implementation methodology that will be used in evaluating the task quality plans to be submitted by the Performing Institutions. The implementing provisions of the program are based on guidance provided in American National Standards Institute/American Society of Mechanical Engineers NQA-1 1994, "Quality Assurance." The individual Performing Institutions will implement the appropriate quality program provisions through their own established quality plans that have been reviewed and found to comply with U.S. Home Team quality assurance plan commitments to the ITER Quality Assurance Program. The extent of quality program provisions

  4. Quality-assurance approach for the Elmo Bumpy Torus Proof-of-Principal experiment

    International Nuclear Information System (INIS)

    Sticksel, F.M.

    1981-01-01

    Components, subsystems and systems will be subjected to inspection and test as necessary to ensure compliance to applicable specifications, Acceptance Test Procedures and/or customer requirements. Quality Assurance will inspect each component, subsystem and system for selected mechanical and electrical defects. In addition, Quality Assurance will either perform, or verify performance of, and analyze, or verify analysis of, all required field and laboratory tests. If hardware is modified, repaired or replaced after final testing, necessary re-inspection and retest must be performed. Insofar as possible the component, subsystem or system will be released as acceptable upon completion of these activities. When nonconformances are detected during the course of site surveillance activities, MDAC or Gilbert/Commonwealth will initiate a Nonconformance Record for review by MDAC Quality Assurance and Project Engineering personnel. These nonconformances will be identified and dispositioned per MDAC Standard Practices with the advice and concurrence of Gilbert/Commonwealth personnel, if deemed appropriate. MDAC Quality Assurance personnel will witness the pre-operational testing and review the test data

  5. MCNP trademark Software Quality Assurance plan

    International Nuclear Information System (INIS)

    Abhold, H.M.; Hendricks, J.S.

    1996-04-01

    MCNP is a computer code that models the interaction of radiation with matter. MCNP is developed and maintained by the Transport Methods Group (XTM) of the Los Alamos National Laboratory (LANL). This plan describes the Software Quality Assurance (SQA) program applied to the code. The SQA program is consistent with the requirements of IEEE-730.1 and the guiding principles of ISO 900

  6. Software Quality Assurance activities of ITER CODAC

    Energy Technology Data Exchange (ETDEWEB)

    Pande, Sopan, E-mail: sopan.pande@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements.

  7. Software Quality Assurance activities of ITER CODAC

    International Nuclear Information System (INIS)

    Pande, Sopan; DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders

    2013-01-01

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements

  8. The selective application of quality assurance activities to nuclear power plant items and services

    International Nuclear Information System (INIS)

    Anderson, J.W.

    1982-01-01

    The definition of quality assurance and the criteria for a quality assurance programme that are contained in both national and international codes and standards provide the principle of selective application of quality assurance activities for cost-effective results. The effective implementation of this principle requires a systematic and disciplined methodology that should be established by or for the owner at the beginning of a nuclear power plant project. The methodology that has proven to be successful generally includes a uniform method of classifying plant items and services at their lowest level of unit assembly and using that classification in the selection of applicable quality assurance activities and the specification of appropriate requirements for those activities. The applicable quality assurance activities are those to be implemented by the organizations designing, manufacturing, installing and operating plant items or performing support services. The methods and techniques provided illustrate the methodology and are one way by which a nuclear power plant project may translate the principle into application in order to achieve the desired results. (author)

  9. Quality assurance during the manufacture of nuclear power plant components

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    Apart from the special requirements of quality assurance in the production of components for the nuclear industry, in particular nuclear power stations, the author discusses special methods of quality control in the testing of welded joints. (TK) [de

  10. The grading management of the quality assurance

    International Nuclear Information System (INIS)

    Ma Xiaozheng; Han Shufang; Yu Bei; Tian Xuehang

    2009-01-01

    This paper introduces the quality assurance grading management of the items, services and technology process on nuclear power plants (nuclear island, conventional island, BOP), such as the requirements and aim in the related code, guide, technical document, the requirements for the related units, the grading principle and grading, the considering method for the differences of QA requirements of the each QA grand, as well as the status and propositions in the QA grading management in China. (authors)

  11. 48 CFR 2453.246 - Quality Assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Quality Assurance. 2453.246 Section 2453.246 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT CLAUSES AND FORMS FORMS Prescription of Forms 2453.246 Quality Assurance. ...

  12. Quality assurance manual: Volume 2, Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department. (LSP)

  13. Quality assurance manual: Volume 2, Appendices

    International Nuclear Information System (INIS)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department

  14. Quality assurance program plan for the Reactor Research Experiment Programs (RREP)

    International Nuclear Information System (INIS)

    Pipher, D.G.

    1982-05-01

    This document describes the Quality Assurance Program plans which will be applied to tasks on Reactor Research Experiments performed on Sandia National Laboratories' reactors. The program provides for individual project or experiment quality plan development and allows for reasonable plan flexibility and maximum plan visibility. Various controls and requirements in this program plan are considered mandatory on all features which are identified as important to public health and safety (Level I). It is the intent of this document that the Quality Assurance program comprise those elements which will provide adequate assurance that all components, equipment, and systems of the experiments will perform as designed, and hence prevent delays and costs due to rejections or failures

  15. The simplification of quality assurance programmes to suit developing countries

    International Nuclear Information System (INIS)

    French, F.J.

    1978-01-01

    Whilst the need to produce and maintain documentation covering the supply and operation of Nuclear Steam Supply Systems is appreciated, it is felt that there is now a tendency to regard such documentation as more important than the plant itself. This tendency must be corrected if the safety and reliability of nuclear plants is to be maintained. The following paper proposes actions which will bring documentation into its proper perspective and make it more easily understood internationally. In addition, it is proposed that a common international Quality Assurance Programme Standard should be adopted by countries importing and exporting NSSS in order to make the requirements more understandable to all concerned. The proposals cover Quality Assurance Systems Specifications and the training of quality engineers and evaluators, and discuss Quality Assurance Programmes and Quality Plans. Specifically, the paper suggests the actions which could be undertaken now and proposes the bodies which should be responsible for such actions. (author)

  16. Quality assurance for nuclear power plants licensing aspect

    International Nuclear Information System (INIS)

    Borovoy, W.F.G.

    1976-02-01

    For the nuclear industry, specific criteria must be implemented to provide sufficient assurance that nuclear plants will be constructed and operated to conform with design, regulatory and code requirements. In Israel the inspections or audits are performed by the IAEC Licensing Division. Local position on ANSI QA standards as well as the eighteen criteria are shown. Lists of American standards are presented. The responsibility for quality assurance is not shared, but reinforced by each responsible unit in the supply chain. (B.G.)

  17. Principles of spiral CT: III. Quality assurance

    International Nuclear Information System (INIS)

    Suess, C.; Kalender, W.A.

    1998-01-01

    Since its introduction in 1989 spiral CT has gained wide clinical acceptance and meanwhile it covers a large range of CT applications. This new technology, however, has not yet been recognized and acknowledged in the national or international regulations on scanner quality assurance (QA) programs. The conventional QA procedures should be extended to check the distribution of resolution and noise within the image plane. Imaging performance in the axial direction constitutes one of the major advantages of spiral scanning. Therefore, the slice sensitivity profiles and the spatial and low-contrast resolution along the z-axis have to be assessed. The high demands on table feed accuracy require additional tests. We suggest phantoms and procedures to check and quantify these parameters. Thereby, we hope to support the ongoing discussion about spiral CT quality assurance. (orig.) [de

  18. Quality assurance of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Frier, M.; Hesslewood, S.R.

    1980-01-01

    A practical guide has been composed for all persons involved in the preparation and use of radiopharmaceuticals on methods used in quality assurance and their applications. These methods include the calibration of ionization chamber assay calibrators, the determination of radionuclide purity, radiochemical purity and chemical purity, particle size analysis and the measurement of pH. Quality assurance procedures are described for products not described in Compendial Monographs, or where the monograph exists, additional useful information is provided; such radiopharmaceuticals include technetium, indium-labelled and iodine-labelled products. (U.K.)

  19. Quality Assurance in Chinese Higher Education

    Science.gov (United States)

    Li, Yuan

    2010-01-01

    Quality assurance has been integrated into the fabric of higher education in China, with the issue of quality in higher education--how to evaluate it and how to enhance it--now taking centre stage in Chinese higher education. In the past decade, the development of quality assurance in Chinese higher education has covered a broad spectrum of…

  20. Hungary Higher Education Quality Assurance System

    Directory of Open Access Journals (Sweden)

    Che Ru-shan

    2013-07-01

    Full Text Available Higher education quality assurance system has drawn much attention since 1980s. Most countries are committed to build the higher education quality assurance system to meet international standards. Under such an international trend, Hungary also actively promotes higher education reform, and established Hungarian Accreditation Committee and in order to ensure the quality of higher education.

  1. Quality assurance in TL monitoring of occupational radiation workers in Andhra Pradesh

    International Nuclear Information System (INIS)

    Padma Savitri, P.; Kamble, M.K.; Roy, Madhumita; Reddy, K.S.; Mahajan, J.M.

    2005-01-01

    TLD Services are rendered for personnel dosimetry to Nuclear Fuel Complex, Atomic Minerals Division, Electronic Corporation of India Limited, National Centre for Characterization of Materials, JONAKI, Medical, Research and Industrial institutions of Andhra Pradesh by TLD Unit, Nuclear Fuel Complex, Hyderabad. To ensure the satisfactory performance of the unit, it is mandatory to participate in Quality Assurance Programme periodically. Setting the rules for the Quality Assurance Programme and implementing them systematically in the service requires considerable thought and effort. Quality Assurance and Quality Check Program addressed administrative data/information, equipment checking, issue/processing of dosimeters, dose evaluation, record keeping, reporting, traceability and reproducibility. In this paper results of Quality Assurance Checks conducted by TLD Unit, NFC as well as C and DRS, RPAD, BARC, Mumbai for the last six years and Internal Quality Checks conducted within TLD Unit, NFC are presented and discussed. Systematic errors in dose evaluation were identified and minimized. Methods to improve the performance are also suggested. (author)

  2. Application of Quality Assurance Mechanisms for Effective Library ...

    African Journals Online (AJOL)

    The main strategy used for implementation of quality assurance was integration of the library` services quality assurance agenda into the university structures and the quality assurance mechanisms available and used in Nigerian university libraries were programme accreditation and benchmarking of library systems.

  3. Software quality assurance: in large scale and complex software-intensive systems

    NARCIS (Netherlands)

    Mistrik, I.; Soley, R.; Ali, N.; Grundy, J.; Tekinerdogan, B.

    2015-01-01

    Software Quality Assurance in Large Scale and Complex Software-intensive Systems presents novel and high-quality research related approaches that relate the quality of software architecture to system requirements, system architecture and enterprise-architecture, or software testing. Modern software

  4. 200 Area Liquid Effluent Facilities -- Quality assurance program plan

    International Nuclear Information System (INIS)

    Fernandez, L.

    1995-01-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance and management controls used by the 200 Area Liquid Effluent Facilities (LEF) to perform its activities in accordance with DOE Order 5700.6C. The 200 Area LEF consists of the following facilities: Effluent Treatment Facility (ETF); Treated Effluent Disposal Facility (TEDF); Liquid Effluent Retention facility (LERF); and Truck Loading Facility -- (Project W291). The intent is to ensure that all activities such as collection of effluents, treatment, concentration of secondary wastes, verification, sampling and disposal of treated effluents and solids related with the LEF operations, conform to established requirements

  5. 30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Safety and pollution prevention equipment... Gas Production Safety Systems § 250.806 Safety and pollution prevention equipment quality assurance... install only certified safety and pollution prevention equipment (SPPE) in wells located on the OCS. SPPE...

  6. Quality assurance management plan (QAPP) special analytical support (SAS)

    Energy Technology Data Exchange (ETDEWEB)

    LOCKREM, L.L.

    1999-05-20

    It is the policy of Special Analytical Support (SAS) that the analytical aspects of all environmental data generated and processed in the laboratory, subject to the Environmental Protection Agency (EPA), U.S. Department of Energy or other project specific requirements, be of known and acceptable quality. It is the intention of this QAPP to establish and assure that an effective quality controlled management system is maintained in order to meet the quality requirements of the intended use(s) of the data.

  7. Quality assurance management plan (QAPP) special analytical support (SAS)

    International Nuclear Information System (INIS)

    LOCKREM, L.L.

    1999-01-01

    It is the policy of Special Analytical Support (SAS) that the analytical aspects of all environmental data generated and processed in the laboratory, subject to the Environmental Protection Agency (EPA), U.S. Department of Energy or other project specific requirements, be of known and acceptable quality. It is the intention of this QAPP to establish and assure that an effective quality controlled management system is maintained in order to meet the quality requirements of the intended use(s) of the data

  8. Quality assurance in dosimetry and treatment planning

    International Nuclear Information System (INIS)

    Cunningham, J.R.

    1984-01-01

    The considerations of tissue response to radiation absorbed dose suggest a need for an accuracy of +/-5% in its delivery. This is very demanding and its regular achievement requires careful quality control. There are three distinct phases to the delivery of the planned treatment: calibration of the radiation beam in a reference situation, calculation of the dose distribution for a patient relative to the reference dose and the delivery of the radiation to the patient as planned. Each has distinctly different quality assurance requirements and must be diligently observed if the desired accuracy is to be achieved

  9. Utility QA viewpoint: Quality assurance program conforming to 10CFR50, Appendix B and 10CFR71, subpart H

    International Nuclear Information System (INIS)

    Grodi, D.L.

    1987-01-01

    The Nuclear Regulatory Commission issued IE Information Notice No. 84-50: ''Clarification of Scope of Quality Assurance Programs for Transport Packages Pursuant to 10CFR50, Appendix B, in June, 1984. The reason for this notice was to eliminate confusion applicable to the quality assurance provisions of Appendix B, 10CFR50 to certain transport packages for which a quality assurance program is required by 10 CFR 71. The purpose of this paper is to provide methodology for establishing, implementing and verifying that all 10CFR71, Subpart H requirements are met with the utility's NRC approved 10CFR50, Appendix B Quality Assurance Program when utilizing a contractor (with a NRC approved Quality Assurance Program for Radioactive Waste Packaging and Transport) providing the radioactive waste solidification, packaging and transport for the utility. Collectively (utility and contractor) the quality assurance programs will meet the applicable regulatory requirements without the necessity of the utility establishing a separate and specific quality assurance program for Packaging and Transport of Radioactive Waste

  10. Quality assurance and demolition: 2006 symposium

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2006-01-01

    The '2006 Symposium: Quality Assurance and Demolition' jointly organized by compra GmbH and Brenk Systemplanung GmbH this year again focused on quality assurance and the demolition of nuclear facilities as its main topics. The papers presented ranged from issues of clearance and disposal to demolition technologies and status reports about specific demolition projects. The sixteen presentations at the '2006 Symposium: Quality Assurance and Demolition' offered an interesting and very topical cross section of decommissioning and demolition of nuclear facilities in Germany. In 2007, the conference about similar main topics will again be held at the Schloss Bensberg Grand Hotel. (orig.)

  11. Quality assurance program description: Hanford Waste Vitrification Plant, Part 1

    International Nuclear Information System (INIS)

    1992-01-01

    This document describes the Department of Energy's Richland Field Office (DOE-RL) quality assurance (QA) program for the processing of high-level waste as well as the Vitrification Project Quality Assurance Program for the design and construction of the Hanford Waste Vitrification Plant (HWVP). It also identifies and describes the planned activities that constitute the required quality assurance program for the HWVP. This program applies to the broad scope of quality-affecting activities associated with the overall HWVP Facility. Quality-affecting activities include designing, purchasing, fabricating, handling, shipping, storing, cleaning, erecting, installing, inspecting, testing, maintaining, repairing, and modifying. Also included are the development, qualification, and production of waste forms which may be safely used to dispose of high-level radioactive waste resulting from national defense activities. The HWVP QA program is made up of many constituent programs that are being implemented by the participating organizations. This Quality Assurance program description is intended to outline and define the scope and application of the major programs that make up the HWVP QA program. It provides a means by which the overall program can be managed and directed to achieve its objectives. Subsequent parts of this description will identify the program's objectives, its scope, application, and structure

  12. Quality assurance for health and environmental chemistry: 1986

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Moss, W.D.; Phillips, M.B.; O'Malley, B.T.

    1987-11-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group at the Los Alamos National Laboratory. The philosophy, methodology, and computing resources used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1986. 27 refs., 3 figs

  13. National Program of Quality Assurance in Radiotherapy in Cuba

    International Nuclear Information System (INIS)

    Alonso Samper, J. L.; Dominguez Hung, L.; Morales Lopez, J. L.; Alfonso Laguardia, R.; Garcia Yip, F.

    2001-01-01

    It tries on the establishment of a Quality Assurance Nacional System, a Quality Assurance Committee implemented in Cuba, and a Quality Auditory National Program implemented in Cuba to control and assure radiotherapy quality

  14. Quality Assurance in the Vandellos 1 Nuclear Power Plant Dismantling and Decommissioning Project

    International Nuclear Information System (INIS)

    Soto Lanuza, A.

    2000-01-01

    General description of the Quality Assurance System established and implemented for the efficient development of the current activities specified in the Dismantling and Decommissioning Plan for Vandellos I Nuclear Power Plant. Aspects related to the Quality organization, scope and applicability on the established Quality Assurance Manual, availability of requirements and recommendations on quality as well as actions to be taken for the correct verification on the quality and practical application of the Manual should be described. (Author)

  15. Quality assurance - how to involve the employees

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    1996-01-01

    An overview of strategies for involvement of employees in quality assurance developement and implementation.......An overview of strategies for involvement of employees in quality assurance developement and implementation....

  16. Quality assurance in the transport and packaging of radioactive material

    International Nuclear Information System (INIS)

    Hale, J.

    1995-01-01

    Quality Assurance (QA) is a requirement of the International Atomic Energy Agency (IAEA) Safety Series No. 6 ''Regulations for Safe Transport of Radioactive Materials.'' It is also, increasingly, a customer requirement. British Nuclear Fuels plc (BNFL) Transport Division has established an integrated management system (including quality and safety) which is being extended to cover environmental aspects. The management system covers the design, procurement, manufacture, testing, documentation, use, maintenance, inspection and decommissioning of all packages used for the transport of radioactive materials and for interim storage. It also covers planning, programming and transport operations. These arrangements cover all modes of transport by road, rail, sea and air. The QA arrangements developed enable Transport Division to demonstrate to Competent Authorities, customers and the general public that the systems in place meet all regulatory requirements. This paper discusses what quality assurance is, why QA arrangements should be introduced and how they were established within Transport Division. Finally, the further developments in the Division's quality arrangements using the tools and techniques of Total Quality Management (TQM) and the European Foundation for Quality Management Model for Self Assessment are described

  17. Definition of a material's quality assurance level

    International Nuclear Information System (INIS)

    Fride, B.

    1990-01-01

    The architecture of expert system COIN (French acronym for classification of Operation Tools) is presented. The system was developed for providing assistance in the determination of the quality level required by the operation tools and their components. Those tools are applied in the maintenance operations in the nuclear power plants and are classified under a Quality Assurance procedure. The characteristics of COIN, its influence on a problem solving method, and the steps of the system's development are summarized [fr

  18. Implementation of quality assurance in the nuclear industry of Republic of Korea

    International Nuclear Information System (INIS)

    Voin, V.

    1985-10-01

    This paper describes the assistance supplied by FRAMEX to achieve establishment and implementation of Quality Assurance Program by Korean Manufacturers. But to assure that equipment purchased in KOREA complies with the procurement documents, technical assistance has been provided to transfer proven, reliable know-how and technology. At this stage of the project, we can say that the total support which is available for the Korean manufacturers is efficient. We have the adequate confidence that the quality of the equipment conforms to predetermined requirements and that it will perform satisfactorily in service. Experienced and qualified personnel in Quality Assurance is now available in KOREA for the development of Korean nuclear program

  19. Quality assurance and nuclear power plant safety

    International Nuclear Information System (INIS)

    Mullan, J.V.

    1983-01-01

    Quality assurance in the nuclear industry was born in the late 1960s. Atomic Energy Control Board staff began its regulatory practice on quality assurance during that period. In this presentation the author traces the circumstances that first led to the establishment of Canadian nuclear power plant quality assurance programmes, summarizes progress over the last decade and a half, and outlines the current regulatory approach and what has been learned so far

  20. Quality assurance of qualitative analysis

    DEFF Research Database (Denmark)

    Ríos, Ángel; Barceló, Damiá; Buydens, Lutgarde

    2003-01-01

    The European Commission has supported the G6MA-CT-2000-01012 project on "Metrology of Qualitative Chemical Analysis" (MEQUALAN), which was developed during 2000-2002. The final result is a document produced by a group of scientists with expertise in different areas of chemical analysis, metrology...... and quality assurance. One important part of this document deals, therefore, with aspects involved in analytical quality assurance of qualitative analysis. This article shows the main conclusions reported in the document referring to the implementation of quality principles in qualitative analysis...

  1. 30 CFR 7.7 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 7.7 Section 7.7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY General § 7.7 Quality assurance. Applicants granted...

  2. Quality assurance plan for Waste Area Grouping 6 at Oak Ridge National Laboratory, Oak Ridge, Tennessee

    International Nuclear Information System (INIS)

    1994-01-01

    This Quality Assurance Plan (QAP) is concerned with design and construction (Sect. 2) and characterization and monitoring (Sect. 3). The basis for Sect. 2 is the Quality Assurance Plan for the Design and Construction of Waste Area Grouping 6 Closure at Oak Ridge National Laboratory, Oak Ridge, Tennessee, and the basis for Sect. 3 is the Environmental Restoration Quality Program Plan. Combining the two areas into one plan gives a single, overall document that explains the requirements and from which the individual QAPs and quality assurance project plans can be written. The Waste Area Grouping (WAG) 6 QAP establishes the procedures and requirements to be implemented for control of quality-related activities for the WAG 6 project. Quality Assurance (QA) activities are subject to requirements detailed in the Martin Marietta Energy Systems, Inc. (Energy Systems), QA Program and the Environmental Restoration (ER) QA Program, as well as to other quality requirements. These activities may be performed by Energy Systems organizations, subcontractors to Energy Systems, and architect-engineer (A-E) under prime contract to the US Department of Energy (DOE), or a construction manager under prime contract to DOE. This plan specifies the overall Energy Systems quality requirements for the project. The WAG 6 QAP will be supplemented by subproject QAPs that will identify additional requirements pertaining to each subproject

  3. Experiences in the application of quality control and quality assurance programmes in water reactor fuel fabrication

    International Nuclear Information System (INIS)

    Balaramamoorthy, K.; Vijayaraghavan, R.; Kulkarni, P.G.; Raghavan, S.V.; Bandyopadhyay, A.K.

    1984-01-01

    Nuclear fuel for Research Reactors and Pressurised Heavy Water Reactors (PHWRs) is being fabricated in India for a period of over two decades. The fuel is produced to conform to stringent quality control specifications. Generally, the performance of the fuel has been very good in the reactors. This is not only due to the high quality workmanship in the various stages of production but also to the meticulous care exercised in the planning and application of quality control and quality assurance procedures. For the nuclear fuel used in Water Reactors, extensive material specifications have been compiled and they are periodically reviewed and revised. The specifications cover various aspects such as metallurgical and mechanical properties, non-destructive testing, dimensional and visual standard requirements. Similarly, detailed manufacturing engineering instructions (MEIs) and quality control instructions (QCIs) have been drawn. For any deviations from the specified requirements, design concession committee considers all deviations and acceptance or rejection criteria are evolved. In this task, the design concession committee is supported by experimentation in various laboratories of the Department of Atomic Energy. The Quality Assurance procedures have been evolved over a long period of time. They generally conform to the latest code and recommended guides of IAEA regarding Quality Assurance in the manufacture of fuel. (orig.)

  4. 44 CFR 19.115 - Assurance required.

    Science.gov (United States)

    2010-10-01

    ... RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 19.115 Assurance required. (a) General. Either at the... 44 Emergency Management and Assistance 1 2010-10-01 2010-10-01 false Assurance required. 19.115 Section 19.115 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF...

  5. Quality assurance for fittings considering nuclear technology

    International Nuclear Information System (INIS)

    Kilian, H.J.

    1987-01-01

    Negative experience made during World War II led to the idea of quality assurance being born in the United States. Thoroughly misunderstood, it came to be incorporated in European mechanical engineering. Quality assurance there was initially considered to be a new term for the oganizational combination of all parts of an enterprise dealing with testing. German manufacturers of heavy-duty and safety fittings represented in the international market were compelled at a relatively early date to properly understand and realize a quality assurance programme. But the multi-fariousness of specifications to be applied and great number of the most different parts made eminent demands on the suitability and variability of the products developed. On the basis of 18 quality criteria the article describes the structure of 'quality' and what its consequences are for an effective quality assurance system - suited for all kinds of specifications. (orig.) [de

  6. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  7. Quality Assurance: Strategic Choices for Higher Education in Turkey

    Directory of Open Access Journals (Sweden)

    Mahmut ÖZER

    2011-01-01

    Full Text Available As the number of students and higher education institutions in the world increases and there is a growing difficulty in financing the higher education systems, decision-makers have begun to show more interest in quality assurance. As quality assurance is given special attention in European countries, developing countries such as Turkey are interested in importing quality assurance systems. It is not possible to set quality assurance without sensitivity toward quality and without having quality as a cultural practice. The most likely encountered quality assurance approach in the world is that the higher education institution itself is responsible for its quality. In addition, external quality assurance procedures used are based on (academic peer review rather than on bureaucratic evaluations. Moreover, there is a lively debate across the world regarding the bureaucratic regulations of the quality assurance agencies and institutions that restrict the autonomy of higher education institutions. Without taking into consideration of the existing centralized structure of the higher education system in Turkey, of meeting social demands for the higher education, and of current higher education enrollment rates, the possible establishment of a quality assurance mechanism that may have sanctions on universities in Turkey is a threat to already limited autonomy of universities and is having a risk of additional bureaucratic burden. By laying out the roles and responsibilities of Turkish Council of Higher Education, the government and universities, this article discusses policies that should be adopted regarding the quality assurance.

  8. Handbook of software quality assurance techniques applicable to the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Bryant, J.L.; Wilburn, N.P.

    1987-08-01

    Pacific Northwest Laboratory is conducting a research project to recommend good engineering practices in the application of 10 CFR 50, Appendix B requirements to assure quality in the development and use of computer software for the design and operation of nuclear power plants for NRC and industry. This handbook defines the content of a software quality assurance program by enumerating the techniques applicable. Definitions, descriptions, and references where further information may be obtained are provided for each topic.

  9. Handbook of software quality assurance techniques applicable to the nuclear industry

    International Nuclear Information System (INIS)

    Bryant, J.L.; Wilburn, N.P.

    1987-08-01

    Pacific Northwest Laboratory is conducting a research project to recommend good engineering practices in the application of 10 CFR 50, Appendix B requirements to assure quality in the development and use of computer software for the design and operation of nuclear power plants for NRC and industry. This handbook defines the content of a software quality assurance program by enumerating the techniques applicable. Definitions, descriptions, and references where further information may be obtained are provided for each topic

  10. Quality assurance system in nuclear engineering

    International Nuclear Information System (INIS)

    Adams, H.W.; Hoensch, V.

    1985-01-01

    Due to the close connection between the German Atomic Energy Law and the nuclear control regulations, quality systems in nuclear engineering have taken on a special form. Quality assurance systems as a stipulated organisation of structure and procedure to assure quality have implications for the organisation of the electric supply company at the planning, erection and commissioning stage and for the organisation of the nuclear power station facility. To supervise the application and effectiveness of the stipulated organisation of structure and procedure internally and externally among contractors, special organisation units have been set up at the plant suppliers, manufactures, electric supply companies and nuclear power station facilities, which in the electric supply field go by the name of Quality Assurance Supervision. (orig.) [de

  11. Quality assurance for health and environmental chemistry: 1989

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Koski, N.L.; Jones, E.A.; Phillips, M.B.; O'Malley, B.T.

    1990-12-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1989. 38 refs., 8 figs., 3 tabs

  12. A Quality Assurance Program for decommissioning

    International Nuclear Information System (INIS)

    Briggs, P.M.

    1986-01-01

    Defining the Quality Assurance Program for the US Department of Energy Shippingport Station Decommissioning Project (SSDP) was a unique opportunity because this is the first full-sized commercial nuclear power plant to be decommissioned. General Electric Company defined a Quality Assurance Program that provided adequate control, yet was stripped down to the essentials. The Program is designed to provide a flexible degree of monitoring of subcontractor work, built around a core of radiation safety monitoring, detailed planning, inspection and auditing, and operated with a minimum of dedicated personnel. This paper will concentrate on the traditional quality assurance activities, leaving radiation and environmental monitoring for other presentations

  13. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  14. Standard guide for establishing a quality assurance program for uranium conversion facilities

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2004-01-01

    1.1 This guide provides guidance and recommended practices for establishing a comprehensive quality assurance program for uranium conversion facilities. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate health and safety practices and determine the applicability of regulatory limitations prior to use. 1.3 The basic elements of a quality assurance program appear in the following order: FUNCTION SECTION Organization 5 Quality Assurance Program 6 Design Control 7 Instructions, Procedures & Drawings 8 Document Control 9 Procurement 10 Identification and Traceability 11 Processes 12 Inspection 13 Control of Measuring and Test Equipment 14 Handling, Storage and Shipping 15 Inspection, Test and Operating Status 16 Control of Nonconforming Items 17 Corrective Actions 18 Quality Assurance Records 19 Audits 20 TABLE 1 NQA-1 Basic Requirements Relat...

  15. A pioneering application of NQA-1 quality assurance standards in the development of software

    International Nuclear Information System (INIS)

    Weisbin, A.N.

    1988-01-01

    The application of NQA-1 Quality Assurance Standards to computer software programs has been recent at the Oak Ridge National Laboratory. One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs. to characterize potential sites for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software

  16. 30 CFR 15.8 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 15.8 Section 15.8 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... § 15.8 Quality assurance. (a) Applicants granted an approval or an extension of approval under this...

  17. Quality Assurance in Sub-Saharan Africa

    Science.gov (United States)

    Materu, Peter; Righetti, Petra

    2010-01-01

    This article assesses the status and practice of higher education quality assurance in sub-Saharan Africa, focusing on degree-granting tertiary institutions. A main finding is that structured national-level quality assurance processes in African higher education are a very recent phenomenon and that most countries face major capacity constraints.…

  18. Quality assurance requirements for the reliability of nuclear power plants in developing countries

    International Nuclear Information System (INIS)

    Bhutta, S.M.

    1978-01-01

    Quality Assurance (QA) has not been taken very seriously in developing countries despite their having significant nuclear power programmes. This may affect plant reliability and demands that urgent and serious attention be given to the development and implementation of Quality Assurance programmes according to local conditions. Confusion has been created by the differences in definitions and interpretations of terminologies of Quality Assurance and Control. Problems have been aggravated by the lack of clearly defined responsibilities and accountabilities during the projects execution phases of site selection, data collection, design, equipment fabrication and construction, etc. Therefore, reliability of nuclear power plants in developing countries is relatively low. But whenever some programme of QA has been implemented it has helped to improve the plant performance. This is highlighted in this paper by the practical examples for the experience of Karachi Nuclear Power Plant whose forced outages have been reduced by over a half within a period of 3 years. In view of the benefits, a QA programme for Chashma Nuclear Power Project has also been initiated. In this paper urgency is emphasized for the establishment and implementation of a formal QA programme in the developing countries if the reactor suppliers and purchasers both want to ensure higher reliability of their plants. The best way that management can play its role effectively is by setting up a strong QA organization with local personnel, thus helping to attain self-reliance and higher reliability during plant operation. (author)

  19. Quality Assurance in Higher Education: Proposals for Consultation.

    Science.gov (United States)

    Higher Education Funding Council for England, Bristol.

    This document sets out for consultation proposals for a revised method for quality assurance of teaching and learning in higher education. The proposals cover: (1) the objectives and principles of quality assurance; (2) an approach to quality assurance based on external audit principles; (3) the collection and publication of information; (4)…

  20. The challenge of Quality Assurance

    International Nuclear Information System (INIS)

    Simon, R.; Price, M.S.T.; Krischer, W.

    1985-01-01

    The safe terminal containment of hazardous wastes cannot only rely upon the geographic remoteness and the arid climates of the repository sites. Radioactive and permanently toxic chemical wastes must by prevented from returning to the human environment by natural and engineered barriers. The long-term integrity of these barriers and the safety of waste emplacement operation will be controlled by systematic actions under the common objective of Quality Assurance (QA). The following paper presents the aims of QA in the design and production of waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organizational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. In view of the technical difficulties of verifying the compliance of industrially produced waste forms with the acceptance criteria, the CEC has laid emphasis on the development of appropriate test methods in its last R and D programme. First results of the work are reviewed in the context of international progress in this field

  1. Quality assurance during operation of nuclear power plants

    International Nuclear Information System (INIS)

    Modemann, G.

    1990-01-01

    The demands of the licensing authorities and the Nuclear Safety Regulations (KTA Rules) on the one hand and the utility's requirements on the other hand have led to the quality assurance system for the operation of nuclear power plants. One part of the system is the organizational structure for the distribution of all tasks and responsibilities to qualified staff members; all checks are carried out by experts who are independent of the executing staff if necessary. The other part of the system comprises the procedural structures for operation, maintenance, inspection, repair and modifications as well as for procurement and preparation of materials and spare parts. The application and efficiency of the quality assurance system is supervised and periodically checked by an independent department. (orig.) [de

  2. Locally fabricated metal step wedge for quality assurance in ...

    African Journals Online (AJOL)

    The code of safe practice for the use of x-rays in medical diagnosis requires that each x-ray facility has an appropriate quality assurance program in radiation protection, to ensure accurate diagnosis, and to keep doses as low as reasonably achievable. This requires an in-house system of regular checks and procedures.

  3. Quality assurance in military medical research and medical radiation accident management.

    Science.gov (United States)

    Hotz, Mark E; Meineke, Viktor

    2012-08-01

    The provision of quality radiation-related medical diagnostic and therapeutic treatments cannot occur without the presence of robust quality assurance and standardization programs. Medical laboratory services are essential in patient treatment and must be able to meet the needs of all patients and the clinical personnel responsible for the medical care of these patients. Clinical personnel involved in patient care must embody the quality assurance process in daily work to ensure program sustainability. In conformance with the German Federal Government's concept for modern departmental research, the international standard ISO 9001, one of the relevant standards of the International Organization for Standardization (ISO), is applied in quality assurance in military medical research. By its holistic approach, this internationally accepted standard provides an excellent basis for establishing a modern quality management system in line with international standards. Furthermore, this standard can serve as a sound basis for the further development of an already established quality management system when additional standards shall apply, as for instance in reference laboratories or medical laboratories. Besides quality assurance, a military medical facility must manage additional risk events in the context of early recognition/detection of health risks of military personnel on deployment in order to be able to take appropriate preventive and protective measures; for instance, with medical radiation accident management. The international standard ISO 31000:2009 can serve as a guideline for establishing risk management. Clear organizational structures and defined work processes are required when individual laboratory units seek accreditation according to specific laboratory standards. Furthermore, international efforts to develop health laboratory standards must be reinforced that support sustainable quality assurance, as in the exchange and comparison of test results within

  4. Nevada Nuclear Waste Storage Investigations: Quality Assurance Plan

    International Nuclear Information System (INIS)

    1980-08-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) were established by DOE/NV to evaluate the geohydrologic setting and underground rock masses of the Nevada Test Site (NTS) and contiguous areas to determine whether a suitable site exists for constructing a repository for isolating highly radioactive solid wastes. Since the results of these evaluations will impact possible risks to public health and safety, a quality assurance program which conforms to the criteria given in the Code of Federal Regulations is needed to control the quality aspects of the work. This Quality Assurance Plan (QAP) describes the general quality assurance program for the overall NNWSI project under which the quality assurance programs of the individual participating organizations and support contractors are to operate. The details of how each of these groups will meet the criteria will differ among participating organizations and support contractors, and those details are given in the QAPP's listed in Appendix A. It is the purpose of this plan to show the commonality of quality assurance programs in effect within the project and to define how each element fits into the entire picture to give total quality assurance coverage for the NNWSI Project

  5. Quality assurance and quality control in fabrication of heat exchanger tubes

    International Nuclear Information System (INIS)

    Duennewald, A.

    1980-01-01

    Object of this report is the manufacture of heat exchanger tubes. A comprehensive manufacturing and test program has to be established to assure and prove and equal tube quality. This requires a functionally operating quality assurance system combined with a production exactly planned in advance. A specific continuous production line for heat exchanger tubes has been erected at the Hellenthal plant of the Mannesmannroehren-Werke. All production steps and heat treatments are generally controlled by a quality control department. Non-destructive testing of each tube produced in standard length is performed on several agregates in line using ultrasonic and/or eddy current technique. All tests are generally performed in the presence of quality inspectors or surveyors. For a lot of heat exchangers the straight tubes have to be hairpin bended. To avoid the risk of stress corrosion cracking, it is recommended to procreate defined compression stresses in the outside tube surface. Prior to releasing the tubes to shipment, the completeness of the documentation as to the manufacturing steps and inspection agreed upon is thoroughly checked. (RW)

  6. Quality assurance of the French nuclear market - IAEA code and standardization

    International Nuclear Information System (INIS)

    Pavaux, F.

    1980-06-01

    The fact that Quality Assurance was imported from abroad and our reticence to reach agreement on single and accurate texts explain, if not excuse, the abundance of reference requirements existing on the French nuclear market with respect to Quality Assurance Programmes. But all is not lost, since the IAEA Good Practice Code is perhaps the solution that, in a few years time, will enable all French industrialists to work and be assessed by their customers, according to the same reference text [fr

  7. Final Hanford Site Transuranic (TRU) Waste Characterization Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    GREAGER, T.M.

    1999-01-01

    The Transuranic Waste Characterization Quality Assurance Program Plan required each US Department of Energy (DOE) site that characterizes transuranic waste to be sent the Waste Isolation Pilot Plan that addresses applicable requirements specified in the QAPP

  8. Construction quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1983-10-01

    This Standard contains the requirements for the quality assurance program applicable to the construction phase of a nuclear power plant. This Standard covers all activities carried out for and by the owner from the receipt of components or materials on the site to their incorporation in systems or structures as required by drawings or other formal engineering information. It also covers the provision of required support activities and equipment and applies at all stages on the site as far as the testing of components or systems before they are submitted for commissioning. 2 figs.

  9. Construction quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1983-10-01

    This Standard contains the requirements for the quality assurance program applicable to the construction phase of a nuclear power plant. This Standard covers all activities carried out for and by the owner from the receipt of components or materials on the site to their incorporation in systems or structures as required by drawings or other formal engineering information. It also covers the provision of required support activities and equipment and applies at all stages on the site as far as the testing of components or systems before they are submitted for commissioning. 2 figs

  10. Quality assurance organization of the plant owner

    International Nuclear Information System (INIS)

    Staebler, K.

    1980-01-01

    It is not the primary task of the plant owner to assure the quality during erection. It is, however, his responsibility to check the quality assurance system established by the plant, the supplier and the subcontractor. In the lecture, it is shown that the plant owners do this control in the best efficient way. The special consideration of the plant owner in deciding questions of quality assurance is demonstrated by special examples. The meaning of basic safety for the plant owner is presented. (orig./RW)

  11. Supplier quality assurance systems: a study in the nuclear industry

    International Nuclear Information System (INIS)

    Singer, A.J.; Churchill, G.F.; Dale, B.G.

    1988-01-01

    The results are reported of a study which investigated the impact of quality assurance on 13 suppliers to the nuclear industry. The purpose of the study was to determine the benefits and problems of applying quality assurance in the supply of high risk plant items and material for nuclear installations. The paper discusses the problems facing the industry including: multiple audits and inspections, the irritation with having to contend with two quality system standards (namely BS 5750 and BS 5882) and the cost effectiveness of the more stringent quality system and quality control surveillance requirements imposed by the nuclear industry. It is also pointed out that companies supplying non-nuclear industrial customers were dissatisfied with the qualifications, experience and professional competence of some auditors and many inspectors. (author)

  12. Development of a quality-assurance program for the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Minor, R.C.

    1981-01-01

    A quality assurance program was developed for TSTA with the attempt in mind to satisfy the developmental nature of the project. Numerous reviews replace strict guidelines because guidelines are one of the objectives of the project, not a basis for it. The reviews assure adequate technical consideration and avoid unilateral decisions. Other major requirements of the program plan include interfacing with another quality assurance organization, the assignment of responsibilities, and instructions for the preparation of SDD's. Areas of concern are, in general, budget related, and include receiving inspection and acceptance of items. A software program is only now being established

  13. Commissioning quality assurance at Pickering NGS

    International Nuclear Information System (INIS)

    Wieckowski, J.T.

    1983-05-01

    Ontario Hydro decided in 1978 to implement a formal quality assurance program applicable to commissioning and operation of nuclear generating stations. Pickering NGS is the first station to have the commissioning quality assurance (CQA) program applied to it. This paper outlines the scope, implementation, and evaluation of the CQA program as applied to Pickering Unit 5

  14. Lonizing radiation regulations and the dental practitioner: 3. Quality assurance in dental radiography.

    Science.gov (United States)

    Rout, John; Brown, Jackie

    2012-06-01

    This is the last in a series of three articles on X-ray dose reduction and covers aspects of quality assurance. The first outlined radiation physics and protection and the second the legislation relating to radiation safety. Quality assurance is an essential part of dental radiography and is required to produce images of a consistently high standard, necessary for accurate diagnosis.

  15. Software for Optimizing Quality Assurance of Other Software

    Science.gov (United States)

    Feather, Martin; Cornford, Steven; Menzies, Tim

    2004-01-01

    Software assurance is the planned and systematic set of activities that ensures that software processes and products conform to requirements, standards, and procedures. Examples of such activities are the following: code inspections, unit tests, design reviews, performance analyses, construction of traceability matrices, etc. In practice, software development projects have only limited resources (e.g., schedule, budget, and availability of personnel) to cover the entire development effort, of which assurance is but a part. Projects must therefore select judiciously from among the possible assurance activities. At its heart, this can be viewed as an optimization problem; namely, to determine the allocation of limited resources (time, money, and personnel) to minimize risk or, alternatively, to minimize the resources needed to reduce risk to an acceptable level. The end result of the work reported here is a means to optimize quality-assurance processes used in developing software.

  16. Quality assurance applied to an environmental surveillance program

    International Nuclear Information System (INIS)

    Oakes, T.W.; Shank, K.E.; Eldridge, J.S.

    1977-01-01

    A discussion of a quality assurance program applied to environmental surveillance activities is presented. This includes the philosophy and concepts of quality assurance, along with a detailed assessment of the sources of uncertainty in a monitoring program. The role management must play for a successful program is also discussed, and the quality assurance program implemented at Oak Ridge National Laboratory is presented

  17. Quality assurance and supervision of mass concrete construction under EPC mode

    International Nuclear Information System (INIS)

    Peng Hong

    2013-01-01

    Taking one typical general contraction project-Hainan Changjiang nuclear power project as an example, this paper introduces the mass concrete construction of nuclear island foundation of Unit 1 in its installation phase, elaborates how to conduct quality assurance and supervision for concrete production, construction, supervision and management, detects relevant weak points of quality and management in the mass concrete construction through quality assurance supervision, puts forward management requirements for the supervising organizations, accumulates useful experience on how to promote contractors to implement the contract in line with national laws, regulations and to improve the management in equipment installation, commissioning and acceptance. (authors)

  18. Quality Assurance in the European Higher Education Area: The Emergence of a German Market for Quality Assurance Agencies

    Science.gov (United States)

    Serrano-Velarde, Kathia E.

    2008-01-01

    Most European countries have introduced systematic quality assurance as part of an overall governance reform aimed at enhancing universities' autonomy. Researchers and economic entrepreneurs tend, however, to underestimate the political dimension of accreditation and evaluation when they consider the contribution of quality assurance to the…

  19. Digital radiography for quality assurance

    International Nuclear Information System (INIS)

    Thiele, H.; Friemel, H.J.

    2001-01-01

    The digital radiographic system AMICA-401 is described. It is a mobile system originally developed for wall thickness and diameter measurements of insulated and non-insulated pipes which is also suited for quality assurance in fabrication and maintenance. Its advantages are immediate evaluation of images, very short exposure times with reduced radiation loads, and an efficient integrated image processing software. Further, no chemical substances are required for film processing. The system can be used both in mobile and in stationary applications. Practical examples are presented and discussed. (orig.) [de

  20. Quality assurance and non-destructive testing for nuclear power plants

    International Nuclear Information System (INIS)

    Manlucu, F.A.

    1991-01-01

    This article discussed the quality assurance requirements which have been extensively applied in plant design, fabrication, construction and operation and has played a major role in the excellent safety record of nuclear power plants. The application of non-destructive testing techniques, plays a very important role during the in-service inspection (ISI) in order to prevent dangerous accident and to assure continuous safe operation of nuclear power plants. (IMA). 12 refs

  1. Nuclear quality assurance programs, their role and their impacts

    International Nuclear Information System (INIS)

    Lex, B.L.

    1978-01-01

    The major steps in the development of control and instrumentation design requirements for a nuclear station, the execution of the detailed design and the procurement, installation and start-up of the control equipment and systems are outlined. The principal quality assurance program requirements related to each of these steps are described and the impact of these requirements on the conduct of the work are examined. (author)

  2. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  3. Quality assurance in processing radioactive waste for land disposal

    International Nuclear Information System (INIS)

    1984-01-01

    To provide the appropriate assurances as to the quality of processed radioactive waste it is necessary to consider the complete range of activities involved in the formation and operation of a radioactive waste processing facility. To this end, an outline has been given to the individual elements which should be addressed in quality assurance proposals to the authorising Departments. In general terms, the quality checks on product material should be aimed at demonstrating that the radioactive waste product is what was agreed at the time of process approval. In addition, at the discretion of the authorising Departments, the waste processor will be required to confirm that the product meets any specific acceptance criteria such as the capability to retain the immobilised radionuclides when in contact with water. (author)

  4. The philosophy of quality assurance in France and its implementation in the regulations

    International Nuclear Information System (INIS)

    Daubresse, G.

    1978-01-01

    In conclusion, quality assurance has developed in France from american ideas and the systems which are being used or are under development remain close to the american ones, but differ from them by their flexibility, adaptability, and by a greater room left to the acceptance of situations not absolutely in conformity with the rules, as long as a real assurance of quality is given. Taking into account the french situation regarding codes and regulations, the efficiency of a good organization of quality management demands, at the very beginning, a clear definition of the quality looked for, and of the technical means to obtain it. That is why, at any level, from the nuclear equipment area to the most classical industries, quality assurance appears as a means to a better mastery of quality, firstly through a definition of the latter in every case, secondly, through technical and organization requirements tuned to the level of quality demanded. Quality assurance is sought through a better organization rather than through an increase of measurements and tests. (orig./RW) [de

  5. Quality assurance for diabetic retinopathy telescreening.

    Science.gov (United States)

    Schneider, S; Aldington, S J; Kohner, E M; Luzio, S; Owens, D R; Schmidt, V; Schuell, H; Zahlmann, G

    2005-06-01

    TOSCA was an EU-Commission supported international research project designed to develop telescreening services in diabetic retinopathy and glaucoma. This paper describes the quality assurance methods developed for the diabetic retinopathy telescreening service within the TOSCA project. The study was performed in 1895 patients with diabetes between 2000 and 2002 at diabetic retinopathy screening sites in five European countries. Data were analysed centrally. Patients attending each clinic's diabetic retinopathy screening service received standardized retinal photography. The images and associated data were transferred electronically to a remote location for grading. Each photographer uploading images and each grader downloading images for assessment was controlled by a systematic quality management approach. The quality assurance measures defined were image quality, intragrader reliability. A cockpit chart was developed for the management and presentation of relevant results and quality measures. For the intragrader reliability tests, 10% of the images were processed for a second grading. An algorithm for calculating differences between repeated gradings was developed. The assessment of image quality for the different sites showed that only 0-0.7% were unassessable. One hundred per cent agreement for both gradings was achieved in 50-85% of graded cases, depending on site and grader, and an agreement better than 95% in 71-100% of cases. A telemedicine-supported quality assurance process is practical and advantageous. The cockpit charts have proven to be useful tools when monitoring the performance of a telescreening service. Grader feedback showed high satisfaction with the quality assurance process.

  6. Revision of the ASME nuclear quality assurance standard and its historical background

    International Nuclear Information System (INIS)

    Suzuki, Tetsuya

    2009-01-01

    ASME NQA-1-2008 'Quality Assurance Requirements for Nuclear Facility Applications' will be endorsed by US NRC by the end of 2009. This standard will apply to design, construction and operation of nuclear power plants newly erected in USA. It is important to Japanese vendors developing nuclear business in USA. Historical background, significance of revision and main revised points of the ASME nuclear quality assurance standard are described in the present paper. (T. Tanaka)

  7. Review of Regulatory Quality Assurance Requirements for the Operation of Nuclear R and D Facilities

    International Nuclear Information System (INIS)

    Kwon, Hyuk Il; Lim, Nam Jin

    2005-01-01

    Korea Atomic Energy Research Institute (KAERI) has many R and D facilities in operation, including HANARO research reactor, radioactive waste treatment facility (RWTF), post-irradiation examination facility (PIEF) and irradiated material test facility (IMEF). Recently, nation-wide interest is focused on the safety and security of major industrial facilities. Safe operation of nuclear facilities is imperative because of the consequence of public disaster by radiological release/ contamination, in case of an accident. Recently, Ministry of Science and Technology (MOST) of the Korean government announced amendments of Atomic Energy laws to enforce requirements of the physical protection and radiological emergency. In this paper, the context of amended Atomic Energy laws were reviewed to confirm quality assurance measures and identify additional QA activities, if any, that is required by the amendment

  8. [Quality assurance and quality management in intensive care].

    Science.gov (United States)

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  9. A pioneering application of NQA-1 quality assurance standards in the development of software

    International Nuclear Information System (INIS)

    Weisbin, A.N.

    1988-01-01

    One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs to characterize potential sited for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software. 2 refs

  10. Quality assurance in Hanford site defense waste operations

    International Nuclear Information System (INIS)

    Wojtasek, R.D.

    1989-01-01

    This paper discusses quality assurance as an integral part of conducting waste management operations. The storage, treatment, and disposal of radioactive and non- radioactive hazardous wastes at Hanford are described. The author reports that quality assurance programs provide confidence that storage, treatment, and disposal facilities and systems perform as intended. Examples of how quality assurance is applied to Hanford defense waste operations are presented

  11. An overview of quality assurance

    International Nuclear Information System (INIS)

    Morris, I.T.

    1983-01-01

    A good quality assurance program seeks to minimise radiation exposure and maximise image quality. Factors considered are equipment performance, films and screens, film processing, viewing conditions and film repeats

  12. The Concepts of Quality, Quality Assurance and Quality Enhancement

    Science.gov (United States)

    Elassy, Noha

    2015-01-01

    Purpose: This paper aims to critically review and discuss different definitions of the concepts of quality, quality assurance (QA) and quality enhancement (QE) in higher education (HE) with presenting critical perspectives of the literature. Design/methodology/approach: The paper looks at literature concerns with the meaning of quality, QA and QE,…

  13. Effect of technology on quality assurance

    International Nuclear Information System (INIS)

    Purvis, E.E. III

    1984-01-01

    Optimizing Quality Assurance activities by taking advantage of technological improvements is an issue directly related to overall product cost, quality, and delivery schedules. Use of automated tooling and numerical control have reduced manufacturing cycle time and thereby enabled better response to changing consumer tastes and market demand. Non-nuclear industries are using computer-aided technology for in-process inspection and final product acceptance. Non-destructive examination can also be performed real-time, on the production line. The challenge faced by the nuclear industry is to make the best use of new and emerging technology while satisfying compliance requirements. Currently, use of new methods is hampered by uncertainty about the affect on regulatory issues. Ways of using the technology have been developed for commercial applications without consideration of nuclear requirements

  14. Assuring quality in narrative analysis.

    Science.gov (United States)

    Bailey, P H

    1996-04-01

    Many nurse-researchers using qualitative strategies have been concerned with assuring quality in their work. The early literature reveals that the concepts of validity and reliability, as understood from the positivist perspective, are somehow inappropriate and inadequate when applied to interpretive research. More recent literature suggests that because of the positivist and interpretive paradigms are epistemologically divergent, the transfer of quality criteria from one perspective to the other is not automatic or even reasonable. The purpose of this article, therefore, is to clarify what the terms quality, trustworthiness, credibility, authenticity, and goodness mean in qualitative research findings. The process of assuring quality, validation, in qualitative research will be discussed within the context of the interpretive method, narrative analysis. A brief review of quality in narrative analysis nursing research will also be presented.

  15. Assessment report for Hanford analytical services quality assurance plan

    International Nuclear Information System (INIS)

    Taylor, L.H.

    1994-11-01

    This report documents the assessment results of DOE/RL-94-55, Hanford Analytical Services Quality Assurance Plan. The assessment was conducted using the Requirement and Self-Assessment Database (RSAD), which contains mandatory and nonmandatory DOE Order statements for the relevant DOE orders

  16. Quality assurance standards: comparison between IAEA 50-C/SG-Q and ISO 9001:1994

    International Nuclear Information System (INIS)

    2000-11-01

    The International Atomic Energy Agency (IAEA) and the International Organization for Standardization (ISO) agreement regarding the scope and coverage of documents published by both organizations points out that the standards of safety developed by the IAEA are recommendations for use by its Member States in the framework of national regulations for the safe utilization of nuclear energy. Such standards should be considered as nuclear safety regulatory documents. The standards developed by the ISO are complementary technical documents emphasizing industrial application and contractual aspects. Regarding the quality assurance topic, the IAEA standards 50-C/SG-Q are mostly used directly or indirectly to establish the nuclear safety requirements at the utility-regulatory interface. The industrial ISO 9001 standards have progressively been used to implement the quality assurance requirements at the interface utility-supplier. The relationship between both standards is growing in significance owing to the impact upon the owners/operators of nuclear facilities and their contractors/suppliers. The relationship between the IAEA and ISO standards is considered critical, in particular regarding suppliers with a small range of nuclear supplies. These organizations are not always willing to prepare special quality assurance programmes based on nuclear safety standards. On the other hand, these organizations may be qualified on the basis of the ISO quality assurance standards. In any case, for delivering nuclear items and services the quality assurance programme must comply with the requirements established in the nuclear safety regulatory standards. This implies that the utility-supplier will have to demonstrate that the acceptable degree of quality assurance in relation to nuclear safety is accomplished. This may be achieved by imposing additional requirements on the supplier over and above those contained within the ISO. In order to provide a description of the differences

  17. Development of a framework of quality assurance practices for a radon passive dosemeter service

    International Nuclear Information System (INIS)

    D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M

    2010-01-01

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  18. Development of a framework of quality assurance practices for a radon passive dosemeter service

    Energy Technology Data Exchange (ETDEWEB)

    D' Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M, E-mail: rosabianca.trevisi@ispesl.i [National Institute for Occupational Prevention and Safety (ISPESL), Via Fontana Candida 1, 00040 Monteporzio Catone (Rome) (Italy)

    2010-06-15

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  19. Development of a framework of quality assurance practices for a radon passive dosemeter service.

    Science.gov (United States)

    D'Alessandro, M; Leonardi, F; Tonnarini, S; Trevisi, R; Veschetti, M

    2010-06-01

    Etched track detectors are widely used for the detection of radon and its decay products. The reliability of radon measurement performed with such devices requires that laboratories producing analytical data are able to provide results of the required quality. The need for uniform results from laboratories at an international level therefore requires the implementation of a quality assurance programme, the harmonization of criteria, sampling procedures, calculations and the reporting of results, agreed on the basis of fundamental principles and international standards. The quality assurance programme described here is the first step on the way to ISO/IEC 17025 certification for the RI-RN (ISPESL) laboratory.

  20. Nuclear power plants - Quality assurance

    International Nuclear Information System (INIS)

    1980-01-01

    This International Standard defines principles for the establishment and implementation of quality assurance programmes during all phases of design, procurement, fabrication, construction, commissioning, operation, maintenance and decommissioning of structures, systems and components of nuclear power plants. These principles apply to activities affecting the quality of items, such as designing, purchasing, fabricating, handling, shipping, storing, cleaning, erecting, installing, testing, commissioning, operating, inspecting, maintaining, repairing, refuelling and modifying and eventually decommissioning. The manner in which the principles described in this document will be implemented in different organizations involved in a specific nuclear power project will depend on regulatory and contractual requirements, the form of management applied to a nuclear power project, and the nature and scope of the work to be performed by different organizations

  1. Quality assurance in the procurement of items and services for nuclear power plants

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the Agency's Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (Safety Series No.50-C-QA), which states requirements for the control of procurement of items and services which are important to the safety of nuclear power plants, for the purpose of achieving quality. The establishment and implementation of controls over the procurement process provide a basis for establishing an appropriate level of confidence that the activities undertaken during procurement of items and services have been performed in accordance with the principles of quality assurance expressed in the Code, and that the required quality of items and services has been achieved. The purchaser, in establishing control over procurement, shall ensure that the quality criteria, quality level, and other quality requirements specified for the particular item or service are taken into account

  2. Requirements for the quality assurance of design, planning and construction for power plants

    International Nuclear Information System (INIS)

    Edelmann, J.

    1981-01-01

    One of the main points of effective quality planning and quality assurance are the organizational conditions. The basic foundation is a development organization with a clear definition of tasks and responsibilities as well as determination of the information flow. Here the dividing of the tasks is to be carried out in a manner where the number of transitions - in particular error-critical transitions - between the individual organization units are minimized. (orig.) [de

  3. Manual on quality assurance for the survey, evaluation and confirmation of nuclear power plant sites

    International Nuclear Information System (INIS)

    1987-04-01

    The present Manual on Quality Assurance for the Survey, Evaluation and Confirmation of Nuclear Power Plant Sites contains supporting material and illustrates examples for implementing the requirements contained in the Code of Practice on Quality Assurance for Safety in Nuclear Power Plants to the activities of survey, evaluation and confirmation of nuclear power plant sites. At the same time the Code of Practice for Safety in Nuclear Power Plant Siting, and Safety Guides in the siting series contain requirements and recommendations to implement a quality assurance programme in selected activities of the siting process. This manual is intended to provide guidance and illustrate examples on this implementation. During preparation and reviews of this Manual it was found out that the methodology of implementation of the quality assurance programme in siting activities is still under development. For these reasons it was considered appropriate to publish this Manual as a temporary publication for trial use

  4. British standard (BS) 5750--quality assurance?

    Science.gov (United States)

    Pratt, D J

    1995-04-01

    BS5750 is the British Standard on "Quality Systems". Its equivalent in European Standards is EN29000 and in the International Standards Organisation ISO9000. This paper points out that these standards lay down formalised procedures and require documentation but do not ipso facto lead to quality assurance. The author points to the Japanese post-war industrial success as being an example of Total Quality Management within the framework provided by the philosophy of Dr. W. Edwards Deming (1988 and 1993). This philosophy on the management of "systems" to provide high quality products and services is briefly outlined. The author argues that improvement in prosthetic and orthotic services will not be reached through implementation of BS5750 but rather through radical rethinking and the adoption and application of the Deming philosophy.

  5. New techniques in quality assurance

    International Nuclear Information System (INIS)

    Fornicola, J.C.

    1987-01-01

    GPU Nuclear Corp. has a multifaceted quality assurance (QA) program. This program includes a comprehensive QA organization to help ensure its implementation. The QA organization employs various techniques in assuring quality at GPU Nuclear. These techniques not only include the typical QA/quality-control verification activities, i.e., QA engineering, quality control, and audits, but also include some new innovative techniques. Several new techniques have been developed for verifying activities. These techniques include monitoring and functional audits of safety systems. Several new techniques for assessing performance and adequacy and effectiveness of plant and QA programs, such as plant assessments and QA systems engineering evaluations, have also been developed. This paper provides an overview of these and other new techniques being employed by GPU Nuclear's QA organization

  6. Application of 5700.6B, quality assurance, to ES and H programs: Mound's approach and results

    International Nuclear Information System (INIS)

    Edling, D.A.

    1985-01-01

    Quality Assurance has always been integral to Mound's production and support operations. Weapons material and other designated material for WR programs are processed and controlled per the requirements of DOE/AL Quality Control Policy QC-1. Mound's non-WR activities, such as siting, design, construction, testing, operation, maintenance, development and production of materials, components, and systems, and acquisition of research and technology data are to be processed and controlled per the requirements of AL Order 5700.6. This paper presents an overview of the entire Quality Assurance Program at Mound and specifically addresses Mound's formal application of Quality Assurance to our comprehensive Environmental, Safety and Health (ES and H) Programs. 4 figures, 1 table

  7. Quality assurance in production and use of special form radioactive material - focal points in BAM approvals

    International Nuclear Information System (INIS)

    Rolle, A.; Buhlemann, L.

    2004-01-01

    BAM as the competent authority for approval of special form radioactive material attaches great importance to a detailed audit of the required quality assurance programs for design, manufacture, testing, documentation, use, maintenance and inspection. Applicants have to submit, together with application documentation information on general arrangements for quality assurance, as well as on quality assurance in production and in operation. Fields where BAM has often found deficiencies are leak test methods, weld seam quality and the safety level after use

  8. Statistical process control for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  9. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  10. 7 CFR 90.102 - Quality assurance review.

    Science.gov (United States)

    2010-01-01

    ... procedures; (3) A review of records for the calibration and maintenance of equipment; (4) A review of records..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and...

  11. A quality assurance program for nuclear power reactor materials tests at the Ford nuclear reactor

    International Nuclear Information System (INIS)

    Burn, R.R.

    1989-01-01

    The University of Michigan Nuclear Reactor Laboratory Quality Assurance Program has been established to assure that materials testing services provided to electric utilities produce accurate results in accordance with industry standards, sound engineering practice, and customer requirements. The program was prepared to comply with applicable requirements of 10CFR50, Appendix B, of the Code of Federal Regulations and a standard of the American National Standards Institute (ANSI), N45.2. The paper discusses the quality assurance program applicability, organization, qualification and training of personnel, material identification and control, examination and testing, measuring and test equipment, nonconforming test equipment, records, audits, and distribution

  12. Quality assurance during site construction of nuclear power plants

    International Nuclear Information System (INIS)

    1981-01-01

    This Safety Guide provides requirements and recommendations related to the establishment and implementation of a quality assurance programme for the site construction activities at nuclear power plants. These include activities such as fabricating, erecting, installing, handling, storing, cleaning, flushing, inspecting, testing, modifying, repairing, and maintaining

  13. Annual Quality Assurance Conference Presentations by Glynda Smith and Carrie Miller

    Science.gov (United States)

    25th Annual Quality Assurance Conference Presentation: Disinfectants/Disinfection Byproducts –Rules and Requirements and Presentation: Long Term 2 Enhanced Surface Water Treatment Rule (LT2) Cryptosporidium Monitoring

  14. The Marshall Islands radioassay quality assurance program. An overview

    International Nuclear Information System (INIS)

    Hamilton, T.F.; Robison, W.L.; Kehl, S.; Stoker, A.C.; Conrado, C.L.

    2000-01-01

    An extensive quality assurance program to provide high quality data and assessments in support of the Marshall Islands Dose Assessment and Radioecology Program has been developed the Lawrence Livermore National Laboratory. Quality assurance objectives begin with the premise of providing integrated and cost-effective program support (to meet wide-ranging programmatic needs, scientific peer review, and build public confidence) and continue through from design and implementation of large-scale field programs, sampling and sample preparation, radiometric and chemical analyses, documentation of quality assurance/quality control practices, exposure assessments, and dose/risk assessments until publication. The basic structure of the radioassay quality assurance/quality control program can be divided into four essential elements: (1) sample and data integrity control, (2) instrument validation and calibration, (3) method performance testing, validation, development and documentation, and (4) periodic peer review and on-site assessments. While the quality assurance objectives are tailored towards a single research program and the evaluation of major exposure pathways/critical radionuclides pertinent to the Marshall Islands, quality assurance practices that are consistent with proposed criteria designed for laboratory accreditation were attempted to be developed. (author)

  15. Draft consultants' report. Consultants' meeting on requirements regarding the harmonization of laboratory quality assurance systems, 2-5 May 1995, Vienna, Austria

    International Nuclear Information System (INIS)

    2002-01-01

    The consultants were requested to advise the Agency on the realization of a harmonized approach to internationally compatible quality assurance systems. The consultants presented their viewpoint and position papers in relation to initial questions posed, reflecting the international efforts and their own experiences in analytical quality assurance. The consultants made specific recommendations concerning various aspects of the Agency's Analytical Quality Assurance Services Programme

  16. Quality Assurance Training Tracking (QATTS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Training Tracking System (QATTS) which tracks Quality Assurace training given by R7 QA staff to in-house...

  17. 42 CFR 441.474 - Quality assurance and improvement plan.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assurance and improvement plan. 441.474... improvement plan. (a) The State must provide a quality assurance and improvement plan that describes the State... pursue opportunities for system improvement. (b) The quality assurance and improvement plan shall also...

  18. Quality Assurance of Software Used In Aircraft Or Related Products

    Science.gov (United States)

    1993-02-01

    This advisory circular (AC) provides an acceptable means, but not the only means, to show compliance with the quality assurance requirements of Federal Aviation Regulations (FAR) Part 21, Certification Procedures for Products and Parts, as applicable...

  19. Pilot program to assess proposed basic quality assurance requirements in the medical use of byproduct materials

    Energy Technology Data Exchange (ETDEWEB)

    Kaplan, E.; Nelson, K.; Meinhold, C.B. (Brookhaven National Lab., Upton, NY (United States))

    1991-10-01

    In January 1990, the Nuclear Regulatory Commission (NRC) proposed amendments to 10 CFR Part 35 that would require medical licensees using byproduct material to establish and implement a basic quality assurance program. A 60-day real-world trial of the proposed rules was initiated to obtain information beyond that generally found through standard public comment procedures. Volunteers from randomly selected institutions had opportunities to review the details of the proposed regulations and to implement these rules on a daily basis during the trial. The participating institutions were then asked to evaluate the proposed regulations based on their personal experiences. The pilot project sought to determine whether medical institutions could develop written quality assurance programs that would meet the eight performance-based objectives of proposed Section 35.35. In addition, the NRC wanted to learn from these volunteers if they had any recommendations on how the rule could be revised to minimized its cost and to clarify its objectives without decreasing its effectiveness. It was found that licensees could develop acceptable QA programs under a performance-based approach, that most licensee programs did meet the proposed objectives, and that most written QA plans would require consultations with NRC or Agreement State personnel before they would fully meet all objectives of proposed Section 35.35. This report describes the overall pilot program. The methodology used to select and assemble the group of participating licensees is presented. The various workshops and evaluation questionnaires are discussed, and detailed findings are presented. 7 refs.

  20. Pilot program to assess proposed basic quality assurance requirements in the medical use of byproduct materials

    International Nuclear Information System (INIS)

    Kaplan, E.; Nelson, K.; Meinhold, C.B.

    1991-10-01

    In January 1990, the Nuclear Regulatory Commission (NRC) proposed amendments to 10 CFR Part 35 that would require medical licensees using byproduct material to establish and implement a basic quality assurance program. A 60-day real-world trial of the proposed rules was initiated to obtain information beyond that generally found through standard public comment procedures. Volunteers from randomly selected institutions had opportunities to review the details of the proposed regulations and to implement these rules on a daily basis during the trial. The participating institutions were then asked to evaluate the proposed regulations based on their personal experiences. The pilot project sought to determine whether medical institutions could develop written quality assurance programs that would meet the eight performance-based objectives of proposed Section 35.35. In addition, the NRC wanted to learn from these volunteers if they had any recommendations on how the rule could be revised to minimized its cost and to clarify its objectives without decreasing its effectiveness. It was found that licensees could develop acceptable QA programs under a performance-based approach, that most licensee programs did meet the proposed objectives, and that most written QA plans would require consultations with NRC or Agreement State personnel before they would fully meet all objectives of proposed Section 35.35. This report describes the overall pilot program. The methodology used to select and assemble the group of participating licensees is presented. The various workshops and evaluation questionnaires are discussed, and detailed findings are presented. 7 refs

  1. Development of Quality Assurance System and Element for Digital I and C

    International Nuclear Information System (INIS)

    Kim, K. H.; Park, C. K.; Ha, J. H.; Kwon, H. I.

    2008-06-01

    The Quality Assurance system should play an importance role in order to create safety operation. And management of KNICS R and D should have strong leadership to build he safety mind and quality mind. Quality assurance system can help to develop safety management system and to create a positive safety culture in operating organization of nuclear development. The establishment and implementation of QA system is prerequisite for achieving goals of the worker's health, quality, environment and public acceptance in operation of nuclear facilities whether they are regulated by the governmental requirements or not. The focus of nuclear QA system is brought on establishment of an appropriate system and assurance of implementation of the system by continuous improvement of quality problems. As for QA activities related to nuclear R and D, we set up QA systems and supported implementation of the system. We conducted periodic audit of KNICS projects related to safety system development and took corrective actions according to the result. Radiation exposure riskiness of the KAERI's nuclear facilities is lower than that of nuclear power plant and they are more safe. But their safety have being supervised by regulatory body in compliance with laws and technical requirements of nuclear power plant. The present QA system should be changed to an integrated safety management system where elements of environment management, safety management and quality management are complimentarily interacting, and thus meet legal requirements. It is necessary to compare subsystems with KNICS QA and management system requirements to improve the effectiveness of existing implementing procedures in other KNICS projects.

  2. Improving the Quality of Academic Services through Implementation of Internal Quality Assurance System in State Institute of Islamic Studies STS Jambi

    Science.gov (United States)

    Iskandar

    2017-01-01

    Implementation of quality assurance systems in IAIN STS Jambi implemented in early 2012, through the build system of internal quality assurance based on ISO 9001: 2008, in the process of implementation required strong reasons behind not growing atmosphere of academic standards of accreditation of study programs and institutions that are reflected…

  3. Three steps to a more successful quality assurance program

    International Nuclear Information System (INIS)

    Ferriss, W.E.

    1975-01-01

    The three steps that will be presented are by no means a cure-all for the variety of problems and challenges that a Quality Assurance (QA) Department is faced with in its role in the design and construction of a nuclear power plant. However, these steps are considered to be three of the most important ones in the realization of an effective and efficient QA program. Step 1. Awareness. With the multitude of people involved in activities that effect the resultant Quality of Design, Procurement, and Construction of a nuclear power plant, a concerted effort has been put forth at Bechtel to promote 'Quality Awareness'. This effort has resulted in presentations to thousands of engineers, buyers, superintendents, supervisors and many others to make them more aware of their role in the Quality program. These presentations cover the Quality criteria, organizations, manuals, and implementation responsibilities that constitute the Company Quality program. In addition to the above, many specialized courses covering inspection techniques, communications, auditing, problem solving, etc. have been given to the people involved in the Generic Quality Assurance functions. Step 2. Attitude. Nuclear Power Quality requirements are quite stringent and have presented additional requirements to engineers, buyers, and superintendents who have previously designed and constructed fossil fuel power plants. Logically there was a resistance to these new requirements and a number of attitudes had to be changed. The most effective way that we have found to accomplish this is through communications from top management expressing their support of the Quality Program. Step 3. Objective and economical compliance. With the increased awareness and a more positive attitude toward Quality requirements, Bechtel has been able to devote considerable effort on finding effective methods to comply with Quality requirements in the most economical way. The complete presentation will include several examples of

  4. Quality assurance program

    International Nuclear Information System (INIS)

    1977-07-01

    This topical report describes the Gibbs and Hill Quality Assurance Program and sets forth the methods to be followed in controlling quality-related activities performed by Gibbs and Hill and its contractors. The program is based on company experience in nuclear power and related work, and defines a system found effective in providing independent control of quality-related functions and documentation. The scope of the report covers activities involving nuclear safety-related structures, systems, and components covered by Gibbs and Hill' contractual obligation to the Utility Owner for each project

  5. Software quality assurance for safety analysis and risk management at the Savannah River Site

    International Nuclear Information System (INIS)

    Ades, M.J.; Toffer, H.; Crowe, R.D.

    1991-01-01

    As part of its Reactor Operations Improvement Program at the Savannah River Site (SRS), Westinghouse Savannah River Company (WSRC), in cooperation with the Westinghouse Hanford Company, has developed and implemented quality assurance for safety-related software for technical programs essential to the safety and reliability of reactor operations. More specifically, the quality assurance process involved the development and implementation of quality standards and attendant procedures based on industry software quality standards. These procedures were then applied to computer codes in reactor safety and probabilistic risk assessment analyses. This paper provides a review of the major aspects of the WSRC safety-related software quality assurance. In particular, quality assurance procedures are described for the different life cycle phases of the software that include the Requirements, Software Design and Implementation, Testing and Installation, Operation and Maintenance, and Retirement Phases. For each phase, specific provisions are made to categorize the range of activities, the level of responsibilities, and the documentation needed to assure the control of the software. The software quality assurance procedures developed and implemented are evolutionary in nature, and thus, prone to further refinements. These procedures, nevertheless, represent an effective controlling tool for the development, production, and operation of safety-related software applicable to reactor safety and probabilistic risk assessment analyses

  6. Quality Assurance Program description, Defense Waste Processing Facility (DWPF)

    International Nuclear Information System (INIS)

    Maslar, S.R.

    1992-01-01

    This document describes the Westinghouse Savannah River Company's (WSRC) Quality Assurance Program for Defense Waste Processing at the Savannah River Site (SRS). WSRC is the operating contractor for the US Department of Energy (DOE) at the SRS. The following objectives are achieved through developing and implementing the Quality Assurance Program: (1) Ensure that the attainment of quality (in accomplishing defense high-level waste processing objectives at the SRS) is at a level commensurate with the government's responsibility for protecting public health and safety, the environment, the public investment, and for efficiently and effectively using national resources. (2) Ensure that high-level waste from qualification and production activities conform to requirements defined by OCRWM. These activities include production processes, equipment, and services; and products that are planned, designed, procured, fabricated, installed, tested, operated, maintained, modified, or produced

  7. Quality assurance of the modernized Dukovany I and C safety system software

    International Nuclear Information System (INIS)

    Karpeta, C.

    2005-01-01

    The approach to quality assurance of the software that implements the instrumentation and control functions for safety category A as per IEC 61226, which has been adopted within the 'NPP Dukovany I and C Refurbishment' project, is described. A survey of the requirements for software quality assurance of the systems that initiate protection interventions in the event of anticipated operational occurrences or accident conditions is given. The software development process applied by the system designers and manufacturers, from the software requirements specification phase to the software testing phase, is outlined. Basic information on technical audits of the software development process is also provided. (orig.)

  8. Quality assurance in the design

    International Nuclear Information System (INIS)

    Edelmann, J.

    1980-01-01

    System- and product-related quality assurance measures are completing one another. Certainly it is possible to detect a lot of defects in the single technical document by well controlled product related quality inspections and to avoid the consequences of these defects; but also a not unimportant part of defects and deviations has its origin in system linked deficiencies. The latter can be detected more easily and more securely by means of system related reviews (System audit, Product audit). But also the sole implementation of system related quality assurance measures keeps the danger to get stuck only in formality and to loose all references to the specific characteristics of the product. (orig./RW)

  9. The quality assurance program at K & S

    Energy Technology Data Exchange (ETDEWEB)

    Slowey, T.W. [AAPM Accredited Dosimetry Calibration Laboratory, Nashville, TN (United States)

    1993-12-31

    K & S operates the largest and one of the most comprehensive Accredited Dosimetry Calibration Laboratories (ADCLs) in the American Association of Physicists in Medicine (AAPM) secondary laboratory system. It offers calibrations covering energies from Grenz-Ray (0.03-mm Al) to cesium-137 and cobalt-60, brachytherapy source and well chamber calibrations for low-activity sources, and, recently, high-dose-rate iridium-192. The present Quality Assurance (QA) program at K & S began with the AAPM Guidelines for Accreditation (Task Group No. 22 and No. 3, 1989) and grew over the past 10 years to include all aspects of providing a private, self-supporting calibration service from a free-standing independent facility. Some aspects of the QA program were prompted by the requirements of the nuclear power industry while other parts were from national consensus standards or the experiences of staff. Redundancy and teamwork are the most important characteristics of this QA program. K & S has participated in a National Institute of Standards and Technology (NIST) measurement quality assurance (MQA) program since 1982, and, in recent years, an ADCL intralaboratory intercomparison was conducted by Task Group 3 of the Radiation Therapy Committee of the AAPM. One measure of the credibility of a QA program is consistent performance on the MQA program and the ADCL intercomparisons over the past 10 years. An equally important measure of the ability of a program to assure quality results is the frequency of reported errors.

  10. Quality assurance protocol for linear accelerators used in radiotherapy

    International Nuclear Information System (INIS)

    Petkovska, Sonja

    2012-01-01

    Radiotherapy is a modality of choice for treatment of malignant diseases. Linear accelerators are the most common devices for implementing external radiation therapy. Taking into account the fact during the treatment, healthy tissue will inevitably be exposed to ionizing radiation, predicted dose in each radiotherapy case should be delivered with the greatest possible accuracy. Medical requirement for quality treatment achieving means as mach as possible dose into volume of interest and the greatest possible healthy tissue protection. From radiation protection point of view, occupational exposure of the staff involved in radiotherapy process should be minimized. To be able to reach it, consistent adherence to the Quality Assurance Programme is necessary. It should be in accordance with higher national and international protocols, because they give guidelines on the necessary standards, procedures, processes, resources and responsibilities that should be defined in structuring the overall radiotherapy quality management. As a part of this Master thesis, quality management as well as Quality Assurance Programme that is necessary to be applied in each radiotherapy center have been prepared. Mandatory dosimetry measurements included in the internal recommendations are also emphasized. Measurement results and external audit by IAEA indicated high accuracy and quality radiotherapy dose delivering in Macedonia. Based on the measurements and analysis, the aim of this Master thesis is offering a Quality Assurance Protocol for external beam radiotherapy that can be used on the national level in Republic of Macedonia. (Author)

  11. Role of quality assurance vs project manager's responsibility for waste projects

    International Nuclear Information System (INIS)

    Solecki, J.

    1989-01-01

    This paper takes a project manager's perspective and discusses the role of the quality assurance organization in the development, implementation and interface related to the QA program for waste projects. The author describes the role which the QA program plays in allowing project management to assure that the project manager knows what is placed in the repository and the characteristics of the surrounding environment meet closure requirements

  12. Quality Assurance in Postgraduate Education. ENQA Workshop Report 12

    Science.gov (United States)

    Bitusikova, Alexandra; Bohrer, Janet; Borosic, Ivana; Costes, Nathalie; Edinsel, Kerim; Hollander, Karoline; Jacobsson, Gunilla; Jakopovic, Ivan Filip; Kearney, Mary-Louise; Mulder, Fred; Negyesi, Judith; Pietzonka, Manuel

    2010-01-01

    The present report follows an ENQA (European Association for Quality Assurance in Higher Education) Workshop on Quality Assurance and Postgraduate Education, hosted by the Romanian Agency for Quality Assurance in Higher Education (ARACIS) in Brasov, Romania on 12-13 March 2009. The workshop was an excellent opportunity for ENQA members to exchange…

  13. Application of quality assurance program to safety related aging equipment or components

    International Nuclear Information System (INIS)

    Papaiya, N.C.

    1990-01-01

    This paper addresses how quality assurance programs and their criteria are applied to safety related and aging equipment or components used in commercial nuclear plant applications. The QA Programs referred to are 10CFR50 Appendix B and EPRI NP-5652. The QA programs as applicable are applied to equipment/component aging qualification, preventive maintenance, surveillance testing and procurement engineering. The intent of this paper is not the technical issues, methods and research of aging. The paper addresses QA program's application to age-related equipment or components in safety related applications. Quality Assurance Program 10CFR50 Appendix B applies to all safety related aging components or equipment related to the qualification program and associated preventive maintenance and surveillance testing programs. Quality Assurance involvement with procurement engineering for age-related commercial grade items supports EPRI NP-5652 and assures that the dedicated OGI is equal to the item purchased as a basic component to 10CFR50 Appendix B requirements

  14. Software quality assurance plan for PORFLOW-3D

    International Nuclear Information System (INIS)

    Maheras, S.J.

    1993-03-01

    This plan describes the steps taken by the Idaho National Engineering Laboratory Subsurface and Environmental Modeling Unit personnel to implement software quality assurance procedures for the PORFLOW-3D computer code. PORFLOW-3D was used to conduct radiological performance assessments at the Savannah River Site. software quality assurance procedures for PORFLOW-3D include software acquisition, installation, testing, operation, maintenance, and retirement. Configuration control and quality assurance procedures are also included or referenced in this plan

  15. Maintenance of the electrical and electronic components and quality assurance

    International Nuclear Information System (INIS)

    Foletto, A.

    1992-01-01

    Quality assurance in the area of maintenance must satisfy certain requirements which concern the materials to be replaced, the working and requalification documentation and the qualifications of the persons carrying out the work. The test systems described in the last section of this article have a dual aim - quality of the work and reduced duration. tabs

  16. Recommendations for a Software Quality Assurance Plan for the CMR Facility at LANL

    International Nuclear Information System (INIS)

    Adams, K.; Matthews, S. D.; McQueen, M. A.

    1998-01-01

    The Nuclear Materials Technology (NMT) organizations 1 and 3 within the Chemical and Metallurgical Research (CMR) facility at the Los Alamos National Laboratory are working to achieve Waste Isolation Pilot Plant (WIPP) certification to enable them to transport their TRU waste to WIPP. This document is intended to provide not only recommendations to address the necessary software quality assurance activities to enable the NMT-1 and NMT-3 organizations to be WIPP compliant but is also meant to provide a template for the final Software Quality Assurance Plan (SQAP). This document specifically addresses software quality assurance for all software used in support of waste characterization and analysis. Since NMT-1 and NMT-3 currently have several operational software products that are used for waste characterization and analysis, these software quality assurance recommendations apply to the operations, maintenance and retirement of the software and the creation and development of any new software required for waste characterization and analyses

  17. Plutonium immobilization project development and testing quality assurance program description - February 1999

    International Nuclear Information System (INIS)

    MacLean, L. M.; Ziemba, J.

    1999-01-01

    Lawrence Livermore National Laboratory Immobilization Development and Testing organization (LLNL ID and T) is a Participant in the Plutonium Immobilization Project (PIP). The LLNL D and T has lead responsibilities for form characterization and qualification, ceramic form development, process/equipment development with plutonium, and process systems testing and validation for both conversion and immobilization. This work must be performed in accordance with the graded approach of a Quality Assurance (QA) Program. A QA Program has been developed at LLNL to meet the requirements of the DOE/MD Quality Assurance Requirements. The LLNL QA Program consists of a Quality Assurance Program Description (QAPD) and Quality Implementing Procedures. These documents interface and are a subset of the overall PIP QA Program Documents. The PIP QA Program is described in the PIP ID and T QA Plan, PIP QAPD, and QA Procedures. Other Participant Organizations also must document and describe their PIP compliant QA Programs in a QAPD and implementing procedures. The purpose of this LLNL QAPD is to describe the organization, management processes, QA Controls for Grading, functional responsibilities, levels of authority, and interfaces for those managing, performing, and assessing the adequacy of work

  18. Proactive quality assurance in environmental research

    International Nuclear Information System (INIS)

    Flanagan, J.B.; Kulkarni, S.V.; Wasson, S.J.; Ford, J.S.; Harmon, D.L.

    1991-01-01

    The Quality Assurance policy of the US Environmental Protection Agency (EPA) stipulates that every project involving environmentally related monitoring, measurements, and data collection activities must have a written and approved quality assurance project plan (QAPjP). A QAPjP is a written document which presents, in specific terms, the policies, organizations, objectives, functional activities, and the quality assurance/quality control activities designed to achieve the quality goals for data collection. In the research studies involving novel or non-routine measurements that use unvalidated methods, measurement quality goals are often difficult or impossible to specify at the beginning of the project for which a QAPjP must be written. Furthermore, it may not be possible for the QAPjP reviewers to evaluate the reasonableness of these goals without initial information about the system under study. For the project to evaluate chlorofluorocarbon for recycling from domestic refrigerators, the QAPjP incorporated standard analytical techniques used by industry. These techniques did not provide accuracy and precision or other validation information. For the initial version of the QAPjP, measurement quality goals were assigned based on limited experience. Quality assurance support was called upon to evaluate the performance of the measurement system for this project through a series of audits. The performance evaluation audits necessitated designing novel audit materials and sample delivery techniques. Continued interaction is necessary between the project and QA teams to permit evolution of reasonable data quality indicators for meaningful assessment of data quality. By treating the QAPjP as a living document that is updated and amended as more knowledge of a system is obtained, AQ becomes an integral part of the research program. This results in a greater understanding of the system under study

  19. Quality assurance and the World Health Organization initiative of 'Health for All'

    International Nuclear Information System (INIS)

    Hanson, G.P.

    1989-01-01

    Following a workshop held in Neuherberg, FRG, in 1980 a guide for quality assurance in diagnostic radiology was published by WHO in 1982. Quality assurance programmes were recognized as being necessary for three main objectives: first the improvement of medical diagnostic imaging, secondly cost containment, and thirdly the reduction of radiation exposure. Concurrently, because of the paramount importance for basic diagnostic imaging, WHO prepared Technical Specifications for the X-ray Apparatus to be Used in a Basic Radiological System (BRS), governed by the concepts of ''design-out maintenance'' and ''design-in quality assurance''. The outcome of WHO's efforts, in comparison with the recognized quality assurance objectives, indicates that, although it is too early to measure overall improvements in medical diagnostic imaging, the two main aspects, accessibility and image quality, should be improved. Regarding cost containment, elimination of many logistical and support requirements should result in considerable savings. Regarding the reduction of radiation exposure, and using the entrance skin exposure as an indicator, an important finding is that with the WHO-BRS type X-ray equipment, in most cases the patient exposure was less than the average values in the United States. (author)

  20. Quality Assurance in Asian Distance Education: Diverse Approaches and Common Culture

    Directory of Open Access Journals (Sweden)

    Insung Jung

    2011-10-01

    Full Text Available With the phenomenal expansion of distance education in Asia during the past three decades, there has been growing public demand for quality and accountability in distance education. This study investigates the national quality assurance systems for distance education at the higher education level in Asia with the aim of contributing to a better understanding of the current level of development of quality assurance in Asian distance education and to offer potential directions for policy makers when developing and elaborating quality assurance systems for distance education. The analysis of the existing quality assurance frameworks in the 11 countries/territories selected reveals that the level of quality assurance policy integration in the overall national quality assurance in higher education policy framework varies considerably. The purpose of quality assurance, policy frameworks, methods, and instruments in place are generally tailored to each country’s particular circumstances. There are, however, obvious commonalities that underpin these different quality assurance efforts.

  1. National Ignition Facility quality assurance plan for laser materials and optical technology

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe, C.R.

    1996-05-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This subtier Quality Assurance Plan (QAP) applies to activities of the Laser Materials & Optical Technology (LM&OT) organization and its subcontractors. It responds to the NIF Quality Assurance Program Plan (QAPP, L-15958-2, NIF-95-499) and Department of Energy (DOE) Order 5700.6C. This Plan is organized according to 10 Quality Assurance (QA) criteria and subelements of a management system as outlined in the NIF QAPP. This Plan describes how those QA requirements are met. This Plan is authorized by the Associate Project Leader for the LM&OT organization, who has assigned responsibility to the Optics QA engineer to maintain this plan, with the assistance of the NIF QA organization. This Plan governs quality-affecting activities associated with: design; procurement; fabrication; testing and acceptance; handling and storage; and installation of NIF Project optical components into mounts and subassemblies.

  2. National Ignition Facility quality assurance plan for laser materials and optical technology

    International Nuclear Information System (INIS)

    Wolfe, C.R.

    1996-05-01

    Quality achievement is the responsibility of the line organizations of the National Ignition Facility (NIF) Project. This subtier Quality Assurance Plan (QAP) applies to activities of the Laser Materials ampersand Optical Technology (LM ampersand OT) organization and its subcontractors. It responds to the NIF Quality Assurance Program Plan (QAPP, L-15958-2, NIF-95-499) and Department of Energy (DOE) Order 5700.6C. This Plan is organized according to 10 Quality Assurance (QA) criteria and subelements of a management system as outlined in the NIF QAPP. This Plan describes how those QA requirements are met. This Plan is authorized by the Associate Project Leader for the LM ampersand OT organization, who has assigned responsibility to the Optics QA engineer to maintain this plan, with the assistance of the NIF QA organization. This Plan governs quality-affecting activities associated with: design; procurement; fabrication; testing and acceptance; handling and storage; and installation of NIF Project optical components into mounts and subassemblies

  3. SGHWR - quality assurance documentation

    International Nuclear Information System (INIS)

    Garrard, R.S.; Caulfield, J.

    1976-01-01

    The quality assurance program for a modern power station such as an SGHWR type reactor plant must include a record of quality achievement. The case history record which is evidence of the actual quality of the plant and is a data bank of design, manufacture, and results of inspections and tests, is described. Documentation distribution, which keeps all key areas informed of plant item quality status, and the retrieval and storage of information, are briefly discussed. (U.K.)

  4. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  5. Quality assurance program. Braun topical report 21

    International Nuclear Information System (INIS)

    1975-01-01

    The Quality Assurance (QA) policies and procedures described have been developed specifically for use in commercial nuclear projects. These policies and procedures are intended to provide assurance to Braun Management and the client that the plant will be safe, reliable, and operable, plus meet the requirements of the Nuclear Regulatory Commission, NRC. The Braun QA Manual provides QA procedures for (1) engineering and design, (2) procurement of materials, equipment, and services, and (3) construction and installation. The controls for safety-related systems established in the manual cover all phases of work from project inception to plant completion prior to operation by the owner. The manual standardizes Braun QA control procedures. These procedures are supplemented by Project QA Instructions prepared for each project. (U.S.)

  6. Quality assurance of radiation therapy machines

    International Nuclear Information System (INIS)

    Francois, P.

    2002-01-01

    Due to the modifications of components, to unexpected breakage of elements or to electronic dysfunctions, the performance of radiotherapy machines may decrease with age. Quality Assurance procedures and maintenance program are necessary to guarantee the performances. For linear accelerators, modus operandi of control tests and their frequency are based on regulations and recommendations widely published, that are presented here. Concerning accessories, especially those recently developed (multi-leaf collimators, dynamic wedges,...), recommendations remains to be defined. Simple tests are proposed. Concerning numerical imaging systems, widely used for three dimensional dosimetry, image quality and geometry controls must be performed with fantom tests. For portal imaging, a quality assurance program is proposed. A strict and complete Quality Assurance program is essential to guarantee quality and safety of the treatment. A regular control of linear accelerator is one of the important component of this program. It suppose the implementation of permanent tests procedures, periodically modified following technological progresses and treatment techniques. Measurements must be sensible to variations below the tolerance level defined during the installation process. The analysis of the variations of measurements with time are an objective criterion of quality. (author)

  7. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, H.T. II; Taylor, A.R. Jr. [Center for Devices and Radiological Health, Rockville, MD (United States)

    1993-12-31

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. This paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory.

  8. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    International Nuclear Information System (INIS)

    Heaton, H.T. II; Taylor, A.R. Jr.

    1993-01-01

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. This paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory

  9. Supplementary quality assurance requirements for installation, inspection, and testing of structural concrete and structural steel during the construction phase of nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1974-01-01

    This standard sets forth the supplementary quality assurance requirements for installation, inspection, and testing of structural concrete and structural steel for nuclear power plant construction. The requirements may also be extended to other appropriate parts of nuclear power plants when specified in contract documents. This standard is intended to be used in conjunction with ANSI N45.2

  10. Quality assurance issues and PACS

    NARCIS (Netherlands)

    Banta, H.D.

    1992-01-01

    Quality assessment and assurance is a growing concern in all areas of health care. The concern is fueled by a body of evidence that indicates that quality of care is not optimal, and in many instances, is unacceptably low. Although different standards for quality have been proposed, health outcome

  11. UMTRA technical assistance contractor quality assurance program plan

    International Nuclear Information System (INIS)

    1994-10-01

    This Quality Assurance Program Plan (QAPP) provides the primary requirements for the integration of quality functions into all Technical Assistance Contractor (TAC) Project organization activities. The QAPP is the written directive authorized by the TAc Program Manager to accomplish this task and to implement procedures that provide the controls and sound management practices needed to ensure TAC contractual obligations are met. The QA program is designed to use monitoring, audit, and surveillance functions as management tools to ensure that all Project organization functions are executed in a manner that will protect public health and safety, promote the success of the Project, and meet or exceed contract requirements

  12. Quality assurance on the Idaho National Engineering Laboratory Buried Waste Program

    International Nuclear Information System (INIS)

    Rasmussen, T.L.

    1989-01-01

    This paper discusses the clean-up of an Idaho National Engineering Laboratory (INEL) site utilized for disposal of transuranic contaminated waste from 1954 until 1970. The author presents requirements of the environmental protection statutes that have generated quality assurance requirements in addition to those historically implemented as a part of facility design, construction and operation. A hierarchy of program guidance quality documentation and procedures is discussed. Data qualification and computer database management are identified as requirements

  13. Quality Assurance 1992-2012

    Science.gov (United States)

    Brown, Roger

    2012-01-01

    As the author's contribution to a series marking the Golden Jubilee of the Association of University Administrators, he reflects on changes in quality assurance over the past twenty years and speculates on what the future may hold for quality as the association moves into a new and very different competitive regime. He begins by discussing the…

  14. 45 CFR 86.4 - Assurance required.

    Science.gov (United States)

    2010-10-01

    ... SEX IN EDUCATION PROGRAMS OR ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 86.4 Assurance required. (a) General. Every application for Federal financial assistance for any education... Director of such assurance. (b) Duration of obligation. (1) In the case of Federal financial assistance...

  15. 10 CFR 1042.115 - Assurance required.

    Science.gov (United States)

    2010-01-01

    ... ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 1042.115 Assurance required. (a) General... applications for Federal financial assistance or awards of Federal financial assistance contain, be accompanied... assurance. (b) Duration of obligation. (1) In the case of Federal financial assistance extended to provide...

  16. The new advances in radiotherapy technique challenges of quality assurance

    International Nuclear Information System (INIS)

    Hegazy, M.; Lecturer of Medical Physics Cairo University, Egypt

    2010-01-01

    What is Quality Assurance (QA)? This is all those planned and systematic actions necessary to provide confidence that a product or service will satisfy given requirements for quality. ISO 9000. It is the overall process which is supported by quality control activities. While, quality control describes the actual mechanisms and procedures by which one can assure quality. Consequences for radiotherapy A good acceptance testing and commissioning program is fundamental for any QA activities QA applies to both physical and clinical aspects of the treatment Treatment records must be kept of all relevant aspects of the treatment - including -Session and Summary Record information -Records all treatment parameters -Dose Calculations -Dose Measurements Particular emphasis is placed on QA of dosimetry A QA system itself and its outcomes must be critically reviewed. External audits are recommended to verify that the checks are not only done but that they also achieve what they are supposed to do Every good system requires an independent look at times A Comprehensive QA Program typically comprises Quality Assurance Committee, Policies and Procedures Manual, Quality Assurance team, Quality audit, Resources Introduction,..OBI in general. The On-Board Imager system is designed to correct for motion and setup errors of patients undergoing radiation therapy. It provides three imaging modes: Two-dimensional 2-D radiographic acquisition, Fluoroscopic image acquisition, and Three-dimensional 3-D cone-beam computed tomography CBCT acquisition. The fluoroscopic images are used to verify the gating thresholds of the respiratory gating system to account for intra-fraction i.e. respiratory motion. The radiographic images manage inter-fractional motion and setup errors. Using the 2D2DMatch and 3D3DMatch analysis tools a user can register the acquired kV or CBCT images with their associated reference image like DRR or planning CT for CBCT. Couch corrections are then downloaded to the linear

  17. Quality assurance feedback as a nursing management strategy.

    Science.gov (United States)

    Brannon, D; Bucher, J A

    1989-01-01

    Quality assurance and effective nurse management can be viewed as intersecting goals. Objective feedback derived from quality assurance data is a potentially powerful means of enhancing nurses' performance and job satisfaction. The use of automated information systems to provide such direct feedback offers the additional advantage of recognizing nurses as self-monitoring, self-correcting professionals. The need, opportunity, and challenge involved in meshing quality assurance with human resource management through computer-generated feedback are discussed in the context of the home health care setting.

  18. Quality Assurance Plan, N springs expedited response action

    International Nuclear Information System (INIS)

    Jackson, G.J.

    1994-01-01

    This document is the Quality Assurance Plan (QAP) to be followed during the definitive design, construction, and operational phases for activities associated with the N Springs Expedited Response Action (ERA) for the 100-NR-2 Operable Unit (OU). Westinghouse Hanford Company (WHC) will comply with the US Department of Energy (DOE) Order 5700.6C, Quality Assurance (DOE 1989), and the US Environmental Protection Agency (EPA), EPA/530-SW-86-031, Technical Guidance Document: Construction Quality Assurance for Hazardous Waste Land Disposal Facilities (EPA 1986)

  19. 22 CFR 146.115 - Assurance required.

    Science.gov (United States)

    2010-04-01

    ... PROGRAMS OR ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 146.115 Assurance required. (a... applications for Federal financial assistance or awards of Federal financial assistance contain, be accompanied... assurance. (b) Duration of obligation. (1) In the case of Federal financial assistance extended to provide...

  20. 49 CFR 25.115 - Assurance required.

    Science.gov (United States)

    2010-10-01

    ... PROGRAMS OR ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 25.115 Assurance required. (a... applications for Federal financial assistance or awards of Federal financial assistance contain, be accompanied... assurance. (b) Duration of obligation. (1) In the case of Federal financial assistance extended to provide...

  1. 22 CFR 229.115 - Assurance required.

    Science.gov (United States)

    2010-04-01

    ... PROGRAMS OR ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE Introduction § 229.115 Assurance required. (a... applications for Federal financial assistance or awards of Federal financial assistance contain, be accompanied... assurance. (b) Duration of obligation. (1) In the case of Federal financial assistance extended to provide...

  2. 45 CFR 605.5 - Assurances required.

    Science.gov (United States)

    2010-10-01

    ... ON THE BASIS OF HANDICAP IN PROGRAMS OR ACTIVITIES RECEIVING FEDERAL FINANCIAL ASSISTANCE General Provisions § 605.5 Assurances required. (a) Assurances. Recipients of Federal financial assistance to which... purpose for which Federal financial assistance is extended or for another purpose involving the provision...

  3. Quality assurance in microbiology

    OpenAIRE

    Arora D

    2004-01-01

    Quality assurance (QA) is the total process whereby the quality of laboratory reports can be guaranteed. The term quality control covers that part of QA, which primarily concerns the control of errors in the performance of tests and verification of test results. All materials, equipment and procedures must be adequately controlled. Culture media must be tested for sterility and performance. Each laboratory must have standard operating procedures (SOPs). QA of pre-analytical, analytical and po...

  4. Material quality assurance risk assessment.

    Science.gov (United States)

    2013-01-01

    Over the past two decades the role of SHA has shifted from quality control (QC) of materials and : placement techniques to quality assurance (QA) and acceptance. The role of the Office of Materials : Technology (OMT) has been shifting towards assuran...

  5. Multi-Function Waste Tank Facility Quality Assurance Program Plan, Project W-236A. Revision 2

    Energy Technology Data Exchange (ETDEWEB)

    Hall, L.R.

    1995-05-30

    This document describes the Quality Assurance (QA) program for the Multi-Function Waste Tank Facility (MWTF) Project. The purpose of this QA program is to control project activities in such a manner as to achieve the mission of the MWTF Project in a safe and reliable manner. The QA program for the MWTF Project is founded on DOE Order 5700.6C, Quality Assurance, and implemented through the use of ASME NQA-1, Quality Assurance Program Requirements for Nuclear Facilities (ASME 1989 with addenda la-1989, lb-1991 and lc-1992). This document describes the program and planned actions which the Westinghouse Hanford Company (WHC) will implement to demonstrate and ensure that the project meets the requirements of DOE Order 5700.6C through the interpretive guidance of ASME NQA-1.

  6. Multi-Function Waste Tank Facility Quality Assurance Program Plan, Project W-236A. Revision 2

    International Nuclear Information System (INIS)

    Hall, L.R.

    1995-01-01

    This document describes the Quality Assurance (QA) program for the Multi-Function Waste Tank Facility (MWTF) Project. The purpose of this QA program is to control project activities in such a manner as to achieve the mission of the MWTF Project in a safe and reliable manner. The QA program for the MWTF Project is founded on DOE Order 5700.6C, Quality Assurance, and implemented through the use of ASME NQA-1, Quality Assurance Program Requirements for Nuclear Facilities (ASME 1989 with addenda la-1989, lb-1991 and lc-1992). This document describes the program and planned actions which the Westinghouse Hanford Company (WHC) will implement to demonstrate and ensure that the project meets the requirements of DOE Order 5700.6C through the interpretive guidance of ASME NQA-1

  7. Quality Assurance for Clinical Trials

    Science.gov (United States)

    Ibbott, Geoffrey S.; Haworth, Annette; Followill, David S.

    2013-01-01

    Cooperative groups, of which the Radiation Therapy Oncology Group is one example, conduct national clinical trials that often involve the use of radiation therapy. In preparation for such a trial, the cooperative group prepares a protocol to define the goals of the trial, the rationale for its design, and the details of the treatment procedure to be followed. The Radiological Physics Center (RPC) is one of several quality assurance (QA) offices that is charged with assuring that participating institutions deliver doses that are clinically consistent and comparable. The RPC does this by conducting a variety of independent audits and credentialing processes. The RPC has compiled data showing that credentialing can help institutions comply with the requirements of a cooperative group clinical protocol. Phantom irradiations have been demonstrated to exercise an institution’s procedures for planning and delivering advanced external beam techniques (1–3). Similarly, RPC data indicate that a rapid review of patient treatment records or planning procedures can improve compliance with clinical trials (4). The experiences of the RPC are presented as examples of the contributions that a national clinical trials QA center can make to cooperative group trials. These experiences illustrate the critical need for comprehensive QA to assure that clinical trials are successful and cost-effective. The RPC is supported by grants CA 10953 and CA 81647 from the National Cancer Institute, NIH, DHHS. PMID:24392352

  8. Quality assurance programme for isotope diagnostic laboratories

    International Nuclear Information System (INIS)

    Krasznai, Istvan

    1987-01-01

    Quality assurance systems are suggested to be introduced in laboratories, in accordance with the recommendations of IAEA and WHO, taking local circumstances into consideration. It is emphasized that a quantitative enhancement of work must not endanger its quality; diagnostic information must be undistorted, reproducible, and gathered with the minimum of radiation burden. National authorities are requested to strengthen their supervision. Recommendations for quality assurance methods are given for medical isotope diagnostic laboratories. (author)

  9. Nuclear powerplant functions: quality assurance, construction

    International Nuclear Information System (INIS)

    Karpa, P.

    1984-01-01

    The author proposes that multilayer Quality Control is burdensome and ineffective. He proposes that the earlier approaches of having responsible field engineers back on the job site instead of at a home office be reinitiated to speed up necessary design changes and hold down costs. It is then the job of the quality control personnel to assure that the field engineer is doing his job. The idea of using the reactor start-up process as part of the quality assurance program is also proposed. Also discussed is the idea of Operating License Contracts or One Step Licensing Approach

  10. Quality Assurance and Quality Control in Point-of-Care Testing.

    Science.gov (United States)

    Newman, Ashleigh W; Behling-Kelly, Erica

    2016-03-01

    With advancements in the standard of care in veterinary medicine and instrument technology, performing in-house laboratory work on a variety of point-of-care instruments, ranging from glucometers to benchtop chemistry analyzers, has become increasingly commonplace. However, the ability of an instrument to perform a test does not guarantee that those results are accurate. Ensuring that your in-clinic laboratory is providing reliable data requires a comprehensive plan that encompasses both common sense practices aimed at preventing errors at each stage of the testing process, as well as standard operating procedures to validate and monitor analyzer performance. These 2 arms of the plan are known as quality assurance and quality control. Although these concepts are typically out of the comfort zone for veterinarians, just as the thought of business management may deter some veterinarians from practice ownership, it is not beyond the capabilities of veterinarians to learn, understand, and incorporate them into their practice. The objectives of this article are to convey the importance of quality assurance and quality control, walk you through the American Society for Veterinary Clinical Pathology guidelines on this topic, and provide direction to additional resources for further education on this topic, all with the focus on point-of-care testing in the in-clinic laboratory. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    International Nuclear Information System (INIS)

    Lewis, Michael G.

    2016-01-01

    This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

  12. Quality Assurance Project Plan for Closure of the Central Facilities Area Sewage Treatment Plant Lagoon 3 and Land Application Area

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, Michael G. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-10-01

    This quality assurance project plan describes the technical requirements and quality assurance activities of the environmental data collection/analyses operations to close Central Facilities Area Sewage treatment Plant Lagoon 3 and the land application area. It describes the organization and persons involved, the data quality objectives, the analytical procedures, and the specific quality control measures to be employed. All quality assurance project plan activities are implemented to determine whether the results of the sampling and monitoring performed are of the right type, quantity, and quality to satisfy the requirements for closing Lagoon 3 and the land application area.

  13. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    Energy Technology Data Exchange (ETDEWEB)

    Busby, Jeremy T [ORNL

    2009-05-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  14. Quality Assurance Protocol for AFCI Advanced Structural Materials Testing

    International Nuclear Information System (INIS)

    Busby, Jeremy T.

    2009-01-01

    The objective of this letter is to inform you of recent progress on the development of advanced structural materials in support of advanced fast reactors and AFCI. As you know, the alloy development effort has been initiated in recent months with the procurement of adequate quantities of the NF616 and HT-UPS alloys. As the test alloys become available in the coming days, mechanical testing, evaluation of optimizing treatments, and screening of environmental effects will be possible at a larger scale. It is therefore important to establish proper quality assurance protocols for this testing effort in a timely manner to ensure high technical quality throughout testing. A properly implemented quality assurance effort will also enable preliminary data taken in this effort to be qualified as NQA-1 during any subsequent licensing discussions for an advanced design or actual prototype. The objective of this report is to describe the quality assurance protocols that will be used for this effort. An essential first step in evaluating quality protocols is assessing the end use of the data. Currently, the advanced structural materials effort is part of a long-range, basic research and development effort and not, as yet, involved in licensing discussions for a specific reactor design. After consultation with Mark Vance (an ORNL QA expert) and based on the recently-issued AFCI QA requirements, the application of NQA-1 quality requirements will follow the guidance provided in Part IV, Subpart 4.2 of the NQA-1 standard (Guidance on Graded Application of QA for Nuclear-Related Research and Development). This guidance mandates the application of sound scientific methodology and a robust peer review process in all phases, allowing for the data to be qualified for use even if the programmatic mission changes to include licensing discussions of a specific design or prototype. ORNL has previously implemented a QA program dedicated to GNEP activities and based on an appropriately graded

  15. Development and implementation of an analytical quality assurance plan at the Hanford site

    International Nuclear Information System (INIS)

    Kuhl-Klinger, K.J.; Taylor, C.D.; Kawabata, K.K.

    1995-08-01

    The Hanford Analytical Services Quality Assurance Plan (HASQAP) provides a uniform standard for onsite and offsite laboratories performing analytical work in support of Hanford Site environmental cleanup initiatives. The Hanford Site is a nuclear site that originated during World War 11 and has a legacy of environmental clean up issues. In early 1993, the need for and feasibility of developing a quality assurance plan to direct all analytical activities performed to support environmental cleanup initiatives set forth in the Hanford Federal Facility Agreement and Consent Order were discussed. Several group discussions were held and from them came the HASQAP. This document will become the quality assurance guidance document in a Federal Facility Agreement and Consent Order. This paper presents the mechanics involved in developing a quality assurance plan for this scope of activity, including the approach taken to resolve the variability of quality control requirements driven by numerous regulations. It further describes the consensus building process and how the goal of uniting onsite and offsite laboratories as well as inorganic, organic, and radioanalytic disciplines under a common understanding of basic quality control concepts was achieved

  16. In-service quality assurance at the Fessenheim nuclear power plant

    International Nuclear Information System (INIS)

    Waller, A.

    1980-01-01

    Quality assurance is a combination of systematic and planned actions applied so as to give the adequate degree of confidence in the effective obtention of quality. Quality assurance is a daily requestioning resulting from systematic inspections and checks. The different principles permitting the in-service quality assurance system to be applied is presented [fr

  17. Quality assurance in biomarker measurement.

    Science.gov (United States)

    Aitio, A; Apostoli, P

    1995-05-01

    Quality assurance (QA) concerns the validity of all the analytical processes (from collection of the samples to interpretation of the results). It is not an abstract concept but must be adapted to the different situations such as the different exposure levels, the different analytical methods, and the context of use (risk assessment procedures, research, routine determinations). The main requirements in QA programmes regard the control of all the known sources of preanalytical and analytical variations, while the instruments with which adequate QA can be implemented are the certified materials and the quality control programmes (quality manual, internal and external quality controls). Another important concept in QA is that measurements must be placed a different metrological levels: at the highest there are the methods (definitive, reference) to be used for assessing accuracy of routine methods. QA programmes should enable a grading of biomarkers (from experimental only to full evaluated) and of the laboratories in order to identify the significance of the test and to assess the level at which a laboratory could operate.

  18. Quality assurance and control for robotic GMA welding

    International Nuclear Information System (INIS)

    Xie Max X.

    1992-01-01

    A quality assurance (QA) model has been developed. This model systematically considers the relevant activities before, during and after the welding operations with respect to quality. Efficient quality assurance requires that the functionality of the present robotic welding systems needs to be increased and that the knowledge of the personnel involved in the design and production needs to be improved. The collaboration between different departments and personnel needs also to be improved. The procedure specification aspects have been studied and a method for the determination of optimal welding parameters is presented with regards to process stability, quality requirements and productivity. A main productivity problem of robotic welding systems for small series production is due to the time spent on the specification of welding procedures. In order to improve the efficiency, expert systems technology has been studied and applied to automatically generate optimal welding procedures. An objective method for the assessment of process stability has been developed, based upon the analysis of the electrical signals of welding arcs. Furthermore, a method has been developed to monitor the process stability. It is found that it is possible to identify the causes of the disturbance of process stability and to predict the weld quality characteristics based on the analysis of the electrical signals. Though quality is formed during the welding operation, the diagnosis of the causes of quality disturbances is important for the prevention of quality problems of subsequent welds and has been discussed. To assist the operators, expert systems technology is also applied. Further work should be directed to the integration of various QA functions in the robotic arc welding system so that both quality and productivity aspects of the system ban be further improved. (au)

  19. Chemical Reactivity Testing for the National Spent Nuclear Fuel Program. Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    Newsom, H.C.

    1999-01-01

    This quality assurance project plan (QAPjP) summarizes requirements used by Lockheed Martin Energy Systems, Incorporated (LMES) Development Division at Y-12 for conducting chemical reactivity testing of Department of Energy (DOE) owned spent nuclear fuel, sponsored by the National Spent Nuclear Fuel Program (NSNFP). The requirements are based on the NSNFP Statement of Work PRO-007 (Statement of Work for Laboratory Determination of Uranium Hydride Oxidation Reaction Kinetics.) This QAPjP will utilize the quality assurance program at Y-12, QA-101PD, revision 1, and existing implementing procedures for the most part in meeting the NSNFP Statement of Work PRO-007 requirements, exceptions will be noted

  20. Quality assurance program for surveillance of fast reactor mixed oxide fuel analytical chemistry

    International Nuclear Information System (INIS)

    Rein, J.E.; Zeigler, R.K.; Waterbury, G.R.; McClung, W.E.; Praetorius, P.R.; Delvin, W.L.

    1976-01-01

    An effective quality assurance program for the chemical analysis of nuclear fuel is essential to assure that the fuel will meet the strict chemical specifications required for optimum reactor performance. Such a program has been in operation since 1972 for the fuels manufactured for the Fast Flux Test Facility. This program, through the use of common quality control and calibration standards, has consistently provided high levels of agreement among laboratories in all areas of analysis. The paper presented gives a summary of the chemical specifications for the fuel and source material, an outline of the requirements for laboratory qualifications and the preparation of calibration and quality control materials, general administration details of the plan, and examples where the program has been useful in solving laboratory problems