WorldWideScience

Sample records for quality assurance methods

  1. Methods of Software Quality Assurance under a Nuclear Quality Assurance Program

    International Nuclear Information System (INIS)

    Kim, Jang Yeol; Lee, Young Jun; Cha, Kyung Ho; Cheon, Se Woo; Lee, Jang Soo; Kwon, Kee Choon

    2005-01-01

    This paper addresses a substantial implementation of a software quality assurance under a nuclear quality assurance program. The relationship of the responsibility between a top-level nuclear quality assurance program such as ASME/NQA-1 and its lower level software quality assurance is described. Software quality assurance activities and software quality assurance procedures during the software development life cycle are also described

  2. Illinois' Forests, 2005: Statistics, Methods, and Quality Assurance

    Science.gov (United States)

    Susan J. Crocker; Charles J. Barnett; Mark A. Hatfield

    2013-01-01

    The first full annual inventory of Illinois' forests was completed in 2005. This report contains 1) descriptive information on methods, statistics, and quality assurance of data collection, 2) a glossary of terms, 3) tables that summarize quality assurance, and 4) a core set of tabular estimates for a variety of forest resources. A detailed analysis of inventory...

  3. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    , on the one hand, to advance internationalisation of quality assurance of higher education, and on the other hand, allow for the differences in the national approaches to quality assurance. The paper will focus on two issues: first, the strength and weaknesses of the method employed and of the use of the ENQA......The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the need...

  4. Laboratory quality assurance

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1977-01-01

    The elements (principles) of quality assurance can be applied to the operation of the analytical chemistry laboratory to provide an effective tool for indicating the competence of the laboratory and for helping to upgrade competence if necessary. When used, those elements establish the planned and systematic actions necessary to provide adequate confidence in each analytical result reported by the laboratory (the definition of laboratory quality assurance). The elements, as used at the Hanford Engineering Development Laboratory (HEDL), are discussed and they are qualification of analysts, written methods, sample receiving and storage, quality control, audit, and documentation. To establish a laboratory quality assurance program, a laboratory QA program plan is prepared to specify how the elements are to be implemented into laboratory operation. Benefits that can be obtained from using laboratory quality assurance are given. Experience at HEDL has shown that laboratory quality assurance is not a burden, but it is a useful and valuable tool for the analytical chemistry laboratory

  5. 42 CFR 440.260 - Methods and standards to assure quality of services.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Methods and standards to assure quality of services. 440.260 Section 440.260 Public Health CENTERS FOR MEDICARE & MEDICAID SERVICES, DEPARTMENT OF HEALTH... and Limits Applicable to All Services § 440.260 Methods and standards to assure quality of services...

  6. The quality assurance liaison: Combined technical and quality assurance support

    International Nuclear Information System (INIS)

    Bolivar, S.L.; Day, J.L.

    1993-01-01

    This paper describes the role of the quality assurance liaison, the responsibilities of this position, and the evolutionary changes in duties over the last six years. The role of the quality assurance liaison has had a very positive impact on the Los Alamos Yucca Mountain Site Characterization (YW) quality assurance program. Having both technical and quality assurance expertise, the quality assurance liaisons are able to facilitate communications with scientists on quality assurance issues and requirements, thereby generating greater productivity in scientific investigations. The quality assurance liaisons help ensure that the scientific community knows and implements existing requirements, is aware of new or changing regulations, and is able to conduct scientific work within Project requirements. The influence of the role of the quality assurance liaison can be measured by an overall improvement in attitude of the staff regarding quality assurance requirements and improved job performance, as well as a decrease in deficiencies identified during both internal and external audits and surveillances. This has resulted in a more effective implementation of quality assurance requirements

  7. Quality assurance and applied statistics. Method 3

    International Nuclear Information System (INIS)

    1992-01-01

    This German-Industry-Standards-paperback contains the International Standards from the Series ISO 9000 (or, as the case may be, the European Standards from the Series EN 29000) concerning quality assurance and including the already completed supplementary guidelines with ISO 9000- and ISO 9004-section numbers, which have been adopted as German Industry Standards and which are observed and applied world-wide to a great extent. It also includes the German-Industry-Standards ISO 10011 parts 1, 2 and 3 concerning the auditing of quality-assurance systems and the German-Industry-Standard ISO 10012 part 1 concerning quality-assurance demands (confirmation system) for measuring devices. The standards also include English and French versions. They are applicable independent of the user's line of industry and thus constitute basic standards. (orig.) [de

  8. Statistical methods for quality assurance

    International Nuclear Information System (INIS)

    Rinne, H.; Mittag, H.J.

    1989-01-01

    This is the first German-language textbook on quality assurance and the fundamental statistical methods that is suitable for private study. The material for this book has been developed from a course of Hagen Open University and is characterized by a particularly careful didactical design which is achieved and supported by numerous illustrations and photographs, more than 100 exercises with complete problem solutions, many fully displayed calculation examples, surveys fostering a comprehensive approach, bibliography with comments. The textbook has an eye to practice and applications, and great care has been taken by the authors to avoid abstraction wherever appropriate, to explain the proper conditions of application of the testing methods described, and to give guidance for suitable interpretation of results. The testing methods explained also include latest developments and research results in order to foster their adoption in practice. (orig.) [de

  9. Quality assurance in NDT

    International Nuclear Information System (INIS)

    Krishnamoorthy, K.

    2010-01-01

    The importance of Nondestructive Testing (NDT) as a Quality Control/Quality Assurance tool in the industrial domain cannot be over-emphasized. With the rapid advancement in research and technology, the NDT field is becoming larger and more sophisticated day by day. Innovative research in materials science and digital technology is paving the way for more and more new methods in NDT technology. Although the NDT technology has improved over the years, the basic 'human factor' underlying the success of the NDT field remains the same. There are two major factors that influence the 'Quality Assurance in NDT'. First, knowledgeable and skilled NDT Operators are the most important factor in assuring the reliable test results. Second, the Management oversight of the NDT operations plays a major role in assuring the overall quality of NDT. Management responsibilities include the implementation of a Quality Management System (QMS) that focuses on the NDT operations and apply all the elements of Quality Assurance relevant to NDT. Whether the NDT operations are performed in-house or by a contractor, periodic Management Self-assessments should include the following question: How can the Management assess and improve the 'Quality Assurance in NDT'? This paper attempts to answer the above question. Some practical examples are provided to illustrate the potential quality incidents that could lead to costly failures, and the role of NDT Operator and the Management in preventing such quality incidents. Also, some guidelines are provided on how the Management can apply the elements of Quality Assurance to NDT in order to assess and improve the 'Quality Assurance in NDT'. (author)

  10. Grading of quality assurance requirements

    International Nuclear Information System (INIS)

    1991-01-01

    The present Manual provides guidance and illustrative examples for applying a method by which graded quality assurance requirements may be determined and adapted to the items and services of a nuclear power plant in conformance with the requirements of the IAEA Nuclear Safety Standards (NUSS) Code and Safety Guides on quality assurance. The Manual replaces the previous publication IAEA-TECDOC-303 on the same subject. Various methods of grading quality assurance are available in a number of Member States. During the development of the present Manual it was not considered practical to attempt to resolve the differences between those methods and it was preferred to identify and benefit from the good practices available in all the methods. The method presented in this Manual deals with the aspects of management, documentation, control, verification and administration which affect quality. 1 fig., 4 tabs

  11. Quality Assurance - Construction

    DEFF Research Database (Denmark)

    Gaarslev, Axel

    1996-01-01

    Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies......Gives contains three main chapters:1. Quality Assurance initiated by external demands2. Quality Assurance initiated by internal company goals3. Innovation strategies...

  12. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Kaul, A.

    1986-01-01

    'Quality Assurance in Nuclear Medicine' is the title of the English language original that has been translated into German. The manual very extensively deals with quality control of nuclear medical equipment. Tests are explained for checking radioactivity measuring devices, manual and automatic in-vitro sample measuring systems, in-vivo measuring systems with single or multiple detectors, rectlinear scanners, and gamma cameras, including the phantoms required for the methods. Other chapters discuss the quality control of radiopharmaceuticals, or the quality assurance in data recording and evaluation of results. Helpful comments on the organisation of quality assurance programms are given. The book is intended as a practical guide for introducing quality assurance principles in nuclear medicine in the Federal Republic of Germany. With 13 figs., 22 tabs [de

  13. Reducing the risk of failure: Software Quality assurance standards and methods

    International Nuclear Information System (INIS)

    Elphick, J.; Cope, H.

    1992-01-01

    An effective Software Quality Assurance (SQA) program provides an overall approach to software engineering and the establishment of proven methods for the production of reliable software. And, in the authors experience, the overall costs for the software life are diminished with the application of quality methods. In their experience, the issues for implementing quality standards and practices are many. This paper addresses those issues as well as the lessons learned from developing and implementing a number of software quality assurance programs. Their experience includes the development and implementation of their own NRC accepted SQA program and an SQA program for an engineering software developer, as well as developing SQA procedures, standards, and methods for utilities, medical and commercial clients. Some of the issues addressed in this paper are: setting goals and defining quality; applying the software life cycle; addressing organizational issues; providing flexibility and increasing productivity; producing effective documentation; maintaining quality records; Imposing software configuration management; conducting reviews, audits, and controls; verification and validation; and controlling software procurement

  14. Quality assurance techniques for activation analysis

    International Nuclear Information System (INIS)

    Becker, D.A.

    1984-01-01

    The principles and techniques of quality assurance are applied to the measurement method of activation analysis. Quality assurance is defined to include quality control and quality assessment. Plans for quality assurance include consideration of: personnel; facilities; analytical design; sampling and sample preparation; the measurement process; standards; and documentation. Activation analysis concerns include: irradiation; chemical separation; counting/detection; data collection, and analysis; and calibration. Types of standards discussed include calibration materials and quality assessment materials

  15. Quality assurance

    International Nuclear Information System (INIS)

    1996-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (NRA SR) was focused on support of quality assurance programmes development at responsible organizations Bohunice V-1 and V-v and Mochovce NPPs and their inspection. Development of the level two documentation of a partial quality assurance programme for NPP operation continued at Mochovce NPP. Most of documentation has been submitted to NRA SR for comments and approval. NRA SR invited a mission of French experts to Mochovce NPP to review preparation and performance of internal audits that would be beneficial for improvement in this kind activities at the NPP. Bohunice NPP continued in development of a partial quality assurance programme for operation. The Quality Assurance Programme submitted to NRA SR for approval. Based on a request of Bohunice NPPs, NRA SR consulted the draft quality assurance programme developed by Siemens for stage of the 'Basic Design' of V-1 NPP upgrading. The programme had not been submitted for approval to NRA SR prior to completion of works by Siemens. Based on an internal audit that had been performed, corrective measures were proposed to meet requirements on review and approval of suppliers quality assurance programmes. Requirements related to the quality assurance at nuclear installations were prepared to be incorporated into principles of a act on peaceful use of nuclear power in Slovak Republic

  16. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    International Nuclear Information System (INIS)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung

    2014-01-01

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently

  17. Basic Study of Establishment of Quality Assurance Processes to Develop an Integrated Quality Assurance System for Nuclear Power Plant Construction

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Byungki; Moon, Byeongsuk; Lee, Jae Kyoung [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    An integrated quality assurance system has necessitated carrying out quality assurance programs in a systematic manner because the opportunities to expand business in overseas markets have increased since the export of a nuclear power plant to UAE in 2009. In this study, we use PDCA method to systematically analyze the quality assurance procedures that were used in previous projects for constructing nuclear power plants. We reached a classification system of quality assurance processes at each phase of nuclear power plant construction by integrating similar work related to quality such as planning, design, equipment manufacturing, construction and start-up. We also established a hierarchy of quality assurance processes to develop an integrated quality assurance system as a technology goal to be developed later. To obtain most updated quality assurance activities, a quality assurance process is structured by integrating similar works analyzed from quality assurance procedures through PDCA cycle method. At the implementation phase of Hierarchy of quality processes and sequence of processes for constructing nuclear power plant are established in this study. Integrated quality assurance system is to be developed by connecting organizations as well as stakeholders such as owners, Architect engineering, suppliers, contractors, and sub-contractors to carry out assigned work efficiently.

  18. Creating Quality Assurance and International Transparency for Quality Assurance Agencies

    DEFF Research Database (Denmark)

    Kristoffersen, Dorte; Lindeberg, Tobias

    2004-01-01

    The paper presents the experiences gained in the pilot project on mutual recognition conducted by the quality assurance agencies in the Nordic countries and the future perspective for international quality assurance of national quality assurance agencies. The background of the project was the nee...

  19. Quality assurance of polymer concrete

    International Nuclear Information System (INIS)

    Schulz, H.

    1984-01-01

    With polymer concrete, a whole range of organisational and functional measures have to be met in order to assure the required quality with an economic expenditure. Quality assurance begins in the design and does not end in the production, rather includes all fields of the enterprise. The following deals with a particular range of the total complex, the inspection methods for assuring the quality of machine components of polymer concrete, particularly machine tool bases, this being through the control of the raw material, the production and the finished product. (orig.) [de

  20. Introduction to quality assurance

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    In today's interpretation 'quality assurance' means 'good management'. Quality assurance has to cover all phases of a work, but all quality assurance measures must be adapted to the relevance and complexity of the actual task. Examples are given for the preparation of quality classes, the organization of quality assurance during design and manufacturing and for auditing. Finally, efficiency and limits of quality assurance systems are described. (orig.)

  1. Quality assurance of radiopharmaceuticals

    International Nuclear Information System (INIS)

    Frier, M.; Hesslewood, S.R.

    1980-01-01

    A practical guide has been composed for all persons involved in the preparation and use of radiopharmaceuticals on methods used in quality assurance and their applications. These methods include the calibration of ionization chamber assay calibrators, the determination of radionuclide purity, radiochemical purity and chemical purity, particle size analysis and the measurement of pH. Quality assurance procedures are described for products not described in Compendial Monographs, or where the monograph exists, additional useful information is provided; such radiopharmaceuticals include technetium, indium-labelled and iodine-labelled products. (U.K.)

  2. Revitalizing quality assurance

    International Nuclear Information System (INIS)

    Hawkins, F.C.

    1998-01-01

    The image of someone inspecting or auditing often comes to mind when people hear the term quality assurance. Although partially correct, this image is not the complete picture. The person doing the inspecting or auditing is probably part of a traditional quality assurance organization, but that organization is only one aspect of a properly conceived and effectively implemented quality assurance system whose goal is improved facility safety and reliability. This paper introduces the underlying philosophies and basic concepts of the International Atomic Energy Agency's new quality assurance initiative that began in 1991 as part of a broad Agency-wide program to enhance nuclear safety. The first product of that initiative was publication in 1996 of a new Quality Assurance Code 50-C/SG-Q and fourteen related Safety Guides. This new suite of documents provide the technical and philosophical foundation upon which Member States can base their quality assurance programs. (author)

  3. Quality assurance

    International Nuclear Information System (INIS)

    Kunich, M.P.; Vieth, D.L.

    1989-01-01

    This paper provides a point/counterpoint view of a quality assurance director and a project manager. It presents numerous aspects of quality assurance requirements along with analyses as to the value of each

  4. KNOWLEDGE AND APPLICATION OF METHODS AND SYSTEMS QUALITY ASSURANCE IN ORCHARD FARMS IN POLAND

    Directory of Open Access Journals (Sweden)

    Eugenia Czernyszewicz

    2013-06-01

    Full Text Available Poland is significant producer of fruits in Europe. After accession to the EU, fruit producers are obligated to comply with operative rules and standards on this market which are related to ensuring commercial and healthcare products of appropriate quality. The quality of fruits available on the market is varied. This results from the fact that in the past, in domestic horticulture, more attention was paid to enlargement of the acreage, the modernization of orchards, increasing the intensity of production and productivity than on issues related to certification and quality management systems. Therefore, the aim of the work was to show the producer's opinion on methods and systems which assure quality of fruits. It was stated that producers have a good knowledge of the methods and systems of fruit quality assurance. Knowledge of these issues is significantly associated with the scale of the fruit production. The knowledge of the principles of integrated fruit production and trading standards GLOBALG.A.P. was declared most often. These methods of quality assurance were also top rated by producers and implemented mostly in farms.

  5. Towards improvement in quality assurance

    International Nuclear Information System (INIS)

    1987-03-01

    This first document in the series of the International Nuclear Safety Advisory Group (INSAG) Technical Notes is a general guideline for the establishment of effective quality assurance procedures at nuclear facilities. It sets out primary requirements such as quality objectives, methods for measuring the effectiveness of the quality assurance programme, priority of activities in relation to importance of safety of items, motivation of personnel

  6. [Integrated quality assurance].

    Science.gov (United States)

    Bögel, K; Stöhr, K

    1994-07-01

    The definition of terms and connotation of "Quality", "Quality Assurance" and "Integration" lead to an analysis and understanding of inhibiting and fostering factors of the "Health Triad" of people, animals and environment. Although "Quality" is largely or ultimately determined by the consumer, there are considerable differences as this term is applied by (a) the individual consumer, (b) the dynamic producer defending or gaining markets, (c) those engaged in traditional product manufacturing, or (d) governments setting (minimum) requirements for the sake of free trade. "Quality Assurance" offers cooperation of partners all along the food chain from "pasture to table". The managerial process turned into a continuum of responsibility and agreement on processes and product characteristics. This overcomes the disadvantages of strategies stressing distinct defense barriers. In practice this philosophy of a predominant role of defence barriers proved largely partnership destructive, in that it permitted to shift responsibilities for failures and to claim administrative competence according to momentary situations and interests. "Integrated Quality Assurance" means mutual agreement of two or more partners along the food chain (e. g. feed producers, farmers, animal health industry, veterinarians and food processors) on product characteristics and production methods. It involves essential system elements including facilities, materials, manpower, information, transport, management etc. Different principles and procedures of quality assurance have been introduced in practice, including agriculture and food processing. These different approaches are not mutually exclusive but largely of complementary nature.(ABSTRACT TRUNCATED AT 250 WORDS)

  7. Multinational Quality Assurance

    Science.gov (United States)

    Kinser, Kevin

    2011-01-01

    Multinational colleges and universities pose numerous challenges to the traditional models of quality assurance that are designed to validate domestic higher education. When institutions cross international borders, at least two quality assurance protocols are involved. To guard against fraud and abuse, quality assurance in the host country is…

  8. Quality assurance requirements and methods for high level waste package acceptability

    International Nuclear Information System (INIS)

    1992-12-01

    This document should serve as guidance for assigning the necessary items to control the conditioning process in such a way that waste packages are produced in compliance with the waste acceptance requirements. It is also provided to promote the exchange of information on quality assurance requirements and on the application of quality assurance methods associated with the production of high level waste packages, to ensure that these waste packages comply with the requirements for transportation, interim storage and waste disposal in deep geological formations. The document is intended to assist both the operators of conditioning facilities and repositories as well as national authorities and regulatory bodies, involved in the licensing of the conditioning of high level radioactive wastes or in the development of deep underground disposal systems. The document recommends the quality assurance requirements and methods which are necessary to generate data for these parameters identified in IAEA-TECDOC-560 on qualitative acceptance criteria, and indicates where and when the control methods can be applied, e.g. in the operation or commissioning of a process or in the development of a waste package design. Emphasis is on the control of the process and little reliance is placed on non-destructive or destructive testing. Qualitative criteria, relevant to disposal of high level waste, are repository dependent and are not addressed here. 37 refs, 3 figs, 2 tabs

  9. Quality assurance of nuclear energy

    International Nuclear Information System (INIS)

    1994-12-01

    It consists of 14 chapters, which are outline of quality assurance of nuclear energy, standard of quality assurance, business quality assurance, design quality assurance, purchase quality assurance, production quality assurance, a test warranty operation warranty, maintenance warranty, manufacture of nuclear power fuel warranty, computer software warranty, research and development warranty and quality audit.

  10. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-03-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of airborne emissions. The Hanford Site radioactive airborne emissions requirements are defined in National Emissions Standards for Hazardous Air Pollutants (NESHAP), Code of Federal Regulations, Title 40, Part 61, Subpart H (EPA 1991a). Reporting of the emissions to the US Department of Energy is performed in compliance with requirements of US Department of Energy, Richland Operations Office Order 5400.1, General Environmental Protection Program (DOE-RL 1988). This Quality Assurance Program Plan is prepared in accordance with and to the requirements of QAMS-004/80, Guidelines and Specifications for Preparing Quality Assurance Program Plans (EPA 1983). Title 40 CFR Part 61, Appendix B, Method 114, Quality Assurance Methods (EPA 1991b) specifies the quality assurance requirements and that a program plan should be prepared to meet the requirements of this regulation. This Quality Assurance Program Plan identifies NESHAP responsibilities and how the Westinghouse Hanford Company Environmental, Safety, Health, and Quality Assurance Division will verify that the methods are properly implemented

  11. The application of quality assurance

    International Nuclear Information System (INIS)

    Lovatt, G.B.

    1988-01-01

    The paper concerns the application of quality assurance to structures, systems and components for the design, construction and operation of nuclear power plant and fuel reprocessing plant. A description is given of:- the requirements for quality assurance, the establishment of quality assurance arrangements, quality assurance documents structure, and quality assurance manuals and programmes. Quality assurance procedures and auditing are also discussed. (U.K.)

  12. Evaluation of a Standardized Method of Quality Assurance in Mental Health Records: A Pilot Study

    Science.gov (United States)

    Bradshaw, Kelsey M.; Donohue, Bradley; Fayeghi, Jasmine; Lee, Tiffany; Wilks, Chelsey R.; Ross, Brendon

    2016-01-01

    The widespread adoption of research-supported treatments by mental health providers has facilitated empirical development of quality assurance (QA) methods. Research in this area has focused on QA systems aimed at assuring the integrity of research-supported treatment implementation, while examination of QA systems to assure appropriate…

  13. Quality assurance within regulatory bodies

    International Nuclear Information System (INIS)

    1999-06-01

    The IAEA directed extensive efforts during the years 1991 to 1995 to the integral revision of all NUSS quality assurance publications, which were approved and issued as Safety Series No.50-C/SG-Q, Quality Assurance for Safety in Nuclear Power Plants and other Nuclear Installations (1996). When these quality assurance publications were developed, their prime focus was on requirements against which work performed by the licensees could be measured and assessed by the regulatory bodies. In this way, they only helped to facilitate the functions of regulators. No requirements or recommendations were provided on how the regulators should ensure the effective implementation of their own activities. The present publication is a first attempt to collect, integrate and offer available experience to directly support performance of regulatory activities. It presents a comprehensive compilation on the application of quality assurance principles and methods by regulatory bodies to their activities. The aim is consistent good performance of regulatory activities through a systematic approach

  14. Quality Assurance in Higher Education: Proposals for Consultation.

    Science.gov (United States)

    Higher Education Funding Council for England, Bristol.

    This document sets out for consultation proposals for a revised method for quality assurance of teaching and learning in higher education. The proposals cover: (1) the objectives and principles of quality assurance; (2) an approach to quality assurance based on external audit principles; (3) the collection and publication of information; (4)…

  15. Data Quality Assurance Governance

    OpenAIRE

    Montserrat Gonzalez; Stephanie Suhr

    2016-01-01

    This deliverable describes the ELIXIR-EXCELERATE Quality Management Strategy, addressing EXCELERATE Ethics requirement no. 5 on Data Quality Assurance Governance. The strategy describes the essential procedures and practices within ELIXIR-EXCELERATE concerning planning of quality management, performing quality assurance and controlling quality. It also depicts the overall organisation of ELIXIR with emphasis on authority and specific responsibilities related to quality assurance.

  16. Regulatory viewpoint on nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    Tripp, L.E.

    1976-01-01

    Considerations of the importance of fuel quality and performance to nuclear safety, ''as low reasonably achievable'' release of radioactive materials in reactor effluents, and past fuel performance problems demonstrate the need for strong regulatory input, review and inspection of nuclear fuel quality assurance programs at all levels. Such a regulatory program is being applied in the United States of America by the US Nuclear Regulatory Commission. Quality assurance requirements are contained within government regulations. Guidance on acceptable methods of implementing portions of the quality assurance program is contained within Regulatory Guides and other NRC documents. Fuel supplier quality assurance program descriptions are reviewed as a part of the reactor licensing process. Inspections of reactor licensee control of their fuel vendors as well as direct inspections of fuel vendor quality assurance programs are conducted on a regularly scheduled basis. (author)

  17. Quality assurance

    International Nuclear Information System (INIS)

    Cante; Feger; Genevray; Hennion; Moneyron; Monneyron; Normand; Rastoin; Silberstein; Vaujour.

    1976-01-01

    The general principles of quality assurance and their applications within the French industrial and commercial regulations are presented. The conditions for the practical application of quality assurance to the different stages of the life of a nuclear power station (design, development, operation) are considered and a special mention is made of nuclear fuels and liquid sodium cooled reactors [fr

  18. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activities and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities wihtin the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  19. Quality assurance for geologic investigations

    International Nuclear Information System (INIS)

    Delvin, W.L.; Gustafson, L.D.

    1983-01-01

    A quality assurance handbook was written to provide guidance in the application of quality assurance to geologic work activities associated with the National Waste Terminal Storage (NWTS) Program. It is intended to help geoscientists and NWTS program managers in applying quality assurance to their work activitie and projects by showing how technical and quality assurance practices are integrated to provide control within those activities and projects. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across the various geologic activities within the NWTS Program. This handbook also can assist quality assurance personnel in understanding the relationships between technical and quality assurance practices. This paper describes the handbook

  20. Characteristics quality system assurance of university programs

    Directory of Open Access Journals (Sweden)

    Lucian Ion Medar

    2011-03-01

    Full Text Available Quality assurance program of study requires time, dedication, effort, innovative thinking and creativity. Competitive research programs monitored by quality assurance system to create the desired results on the relationship between learning and teaching methods and assessment.

  1. Quality assurance of metabolomics.

    Science.gov (United States)

    Bouhifd, Mounir; Beger, Richard; Flynn, Thomas; Guo, Lining; Harris, Georgina; Hogberg, Helena; Kaddurah-Daouk, Rima; Kamp, Hennicke; Kleensang, Andre; Maertens, Alexandra; Odwin-DaCosta, Shelly; Pamies, David; Robertson, Donald; Smirnova, Lena; Sun, Jinchun; Zhao, Liang; Hartung, Thomas

    2015-01-01

    Metabolomics promises a holistic phenotypic characterization of biological responses to toxicants. This technology is based on advanced chemical analytical tools with reasonable throughput, including mass-spectroscopy and NMR. Quality assurance, however - from experimental design, sample preparation, metabolite identification, to bioinformatics data-mining - is urgently needed to assure both quality of metabolomics data and reproducibility of biological models. In contrast to microarray-based transcriptomics, where consensus on quality assurance and reporting standards has been fostered over the last two decades, quality assurance of metabolomics is only now emerging. Regulatory use in safety sciences, and even proper scientific use of these technologies, demand quality assurance. In an effort to promote this discussion, an expert workshop discussed the quality assurance needs of metabolomics. The goals for this workshop were 1) to consider the challenges associated with metabolomics as an emerging science, with an emphasis on its application in toxicology and 2) to identify the key issues to be addressed in order to establish and implement quality assurance procedures in metabolomics-based toxicology. Consensus has still to be achieved regarding best practices to make sure sound, useful, and relevant information is derived from these new tools.

  2. Improving patient safety through quality assurance.

    Science.gov (United States)

    Raab, Stephen S

    2006-05-01

    Anatomic pathology laboratories use several quality assurance tools to detect errors and to improve patient safety. To review some of the anatomic pathology laboratory patient safety quality assurance practices. Different standards and measures in anatomic pathology quality assurance and patient safety were reviewed. Frequency of anatomic pathology laboratory error, variability in the use of specific quality assurance practices, and use of data for error reduction initiatives. Anatomic pathology error frequencies vary according to the detection method used. Based on secondary review, a College of American Pathologists Q-Probes study showed that the mean laboratory error frequency was 6.7%. A College of American Pathologists Q-Tracks study measuring frozen section discrepancy found that laboratories improved the longer they monitored and shared data. There is a lack of standardization across laboratories even for governmentally mandated quality assurance practices, such as cytologic-histologic correlation. The National Institutes of Health funded a consortium of laboratories to benchmark laboratory error frequencies, perform root cause analysis, and design error reduction initiatives, using quality assurance data. Based on the cytologic-histologic correlation process, these laboratories found an aggregate nongynecologic error frequency of 10.8%. Based on gynecologic error data, the laboratory at my institution used Toyota production system processes to lower gynecologic error frequencies and to improve Papanicolaou test metrics. Laboratory quality assurance practices have been used to track error rates, and laboratories are starting to use these data for error reduction initiatives.

  3. Quality assurance handbook for measurement laboratories

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1984-10-01

    This handbook provides guidance in the application of quality assurance to measurement activities. It is intended to help those persons making measurements in applying quality assurance to their work activities by showing how laboratory practices and quality assurance requirements are integrated to provide control within those activities. The use of the guidance found in this handbook should help provide consistency in the interpretation of quality assurance requirements across all types of measurement laboratories. This handbook also can assist quality assurance personnel in understanding the relationships between laboratory practices and quality assurance requirements. The handbook is composed of three chapters and several appendices. Basic guidance is provided by the three chapters. In Chapter 1, the role of quality assurance in obtaining quality data and the importance of such data are discussed. Chapter 2 presents the elements of laboratory quality assurance in terms of practices that can be used in controlling work activities to assure the acquisition of quality data. Chapter 3 discusses the implementation of laboratory quality assurance. The appendices provide supplemental information to give the users a better understanding of the following: what is quality assurance; why quality assurance is required; where quality assurance requirements come from; how those requirements are interpreted for application to laboratory operations; how the elements of laboratory quality assurance relate to various laboratory activities; and how a quality assurance program can be developed

  4. Region III involvement in quality control and quality assurance of radon testing methods

    International Nuclear Information System (INIS)

    Coyle, F.T.

    1990-01-01

    Region III has set a goal of increasing the testing for radon by our residents. One approach to this goal, is to bolster the public's confidence in the testing laboratories. We believe that this can be done most effectively by assuring the quality of the measurements available to the public. All Proficient Laboratories and Pennsylvania Certified Laboratories have submitted a quality assurance (QA) program. A QA audit checklist has been developed which will be finalized and made available to the states in our Region. This paper deals with inspection, verification, and documentation of the various laboratories and their compliance with prudent measuring protocols and addresses the following items: Organization and responsibilities; Sampling procedures; Detector chain of custody; Measurement procedures, quality control checks; State certification and RMP; Data resection, validation, and reporting; Quality assurance reports to management; Interview and discussion of QA audit with responsible officer

  5. Data mining methods for quality assurance in an environmental monitoring network

    NARCIS (Netherlands)

    Athanasiadis, Ioannis N.; Rizzoli, Andrea Emilio; Beard, Daniel W.

    2010-01-01

    The paper presents a system architecture that employs data mining techniques for ensuring quality assurance in an environmental monitoring network. We investigate how data mining techniques can be incorporated in the quality assurance decision making process. As prior expert decisions are

  6. Paediatric rehabilitation treatment standards: a method for quality assurance in Germany

    Directory of Open Access Journals (Sweden)

    Jutta Ahnert

    2014-07-01

    Full Text Available Over the last few years, the German Pension Insurance has implemented a new method of quality assurance for inpatient rehabilitation of children and adolescents diagnosed with bronchial asthma, obesity, or atopic dermatitis: the so-called rehabilitation treatment standards (RTS. They aim at promoting a comprehensive and evidence-based care in rehabilitation. Furthermore, they are intended to make the therapeutic processes in medical rehabilitation as well as potential deficits more transparent. The development of RTS was composed of five phases during which current scientific evidence, expert knowledge, and patient expectations were included. Their core element is the specification of evidence-based treatment modules that describe a good rehabilitation standard for children diagnosed with bronchial asthma, obesity, or atopic dermatitis. Opportunities and limitations of the RTS as a tool for quality assurance are discussed.

  7. Computer software quality assurance

    International Nuclear Information System (INIS)

    Ives, K.A.

    1986-06-01

    The author defines some criteria for the evaluation of software quality assurance elements for applicability to the regulation of the nuclear industry. The author then analyses a number of software quality assurance (SQA) standards. The major extracted SQA elements are then discussed, and finally specific software quality assurance recommendations are made for the nuclear industry

  8. Quality assurance and product quality

    International Nuclear Information System (INIS)

    Lacroix, D.; Bastiani, P. de

    2004-01-01

    The basic quality assurance requirements have to be completed by means that are oriented towards the quality of products; in COGEMA LOGISTICS our approach is based on four principles: 1) an integrated management system: Quality, health and safety, environment 2) an organization based on the responsibility of all actors, trust and transparency 3) a methodical approach to continuously improve the methods that are employed to achieve quality: -process management -corrective and preventive actions -self assessments and various surveys 4) but at the same time strong procedures for control and monitoring of all activities: -technical and quality audits (external and internal) -at source inspections -engineering activities inspections This performance-based approach is necessary to guaranty the effectiveness of the traditional formal QA means

  9. Quality assurance program

    International Nuclear Information System (INIS)

    Brooks, G.L.

    The concept of levels of quality assurance as applied to CANDU-type nuclear power plant components, i.e. maintaining an appropriate cost/benefit ratio, is introduced. The design process itself has quality assurance features by virtue of multi-level review. (E.C.B.)

  10. Quality assurance

    OpenAIRE

    Cauchi, Maurice A.M.

    1993-01-01

    The concept of quality assurance refers more specifically to the process of objectifying and clearly enunciating goals, and providing means of assessing the outcomes. In this article the author mentions four fundamental elements of quality assurance which should be applied in the medical profession in Malta. These elements should relate to professional performance, resource utilisation, risk management and patient satisfaction. The aim of the medical professionals in Malta is to provide the b...

  11. Evaluation of a clinically intuitive quality assurance method

    International Nuclear Information System (INIS)

    Norris, H; Thomas, A; Oldham, M

    2013-01-01

    There is a pressing need for clinically intuitive quality assurance methods that report metrics of relevance to the likely impact on tumor control of normal tissue injury. This paper presents a preliminary investigation into the accuracy of a novel ''transform method'' which enables a clinically relevant analysis through dose-volume-histograms (DVHs) and dose overlays on the patient's CT data. The transform method was tested by inducing a series of known mechanical and delivery errors onto simulated 3D dosimetry measurements of six different head-and-neck IMRT treatment plans. Accuracy was then examined through the comparison of the transformed patient dose distributions and the known actual patient dose distributions through dose-volume histograms and normalized dose difference analysis. Through these metrics, the transform method was found to be highly accurate in predicting measured patient dose distributions for these types of errors.

  12. Methods and quality assurance in environmental medicine. Formation of a RKI-Commission

    International Nuclear Information System (INIS)

    Eis, D.

    2000-01-01

    An almost bewildering number of widely differing methods and techniques, often not validated, are being applied often inappropriately in the field of environmental medicine to answer questions regarding exposure assessment, diagnosis, treatment, counselling and prevention. Therefore, quality control within the field of environmental medicine is quite problematic. A primary goal of the newly formed RKI-Commission 'Methods and Quality Assurance in Environmental Medicine' is to form a panel of experts in the field, who evaluate the situation and generate consensus documents containing respective recommendations. By this the commission will contribute to standardization and agreement on appropriate methods, procedures and their correct application in the practice of environmental medicine. Hopefully it will also achieve a stronger, more consistent use of evidence-based-medicine and improve the quality of the structure, processes and results of research and practice in this field. The committee will initially deal with the issue of clinical environmental medicine, because here the largest problems in quality assurance are seen. In this context the commission will look at the problem areas of environmental-medical outpatient units and environmental clinics. The work of the commission will be supported by the newly formed Documentation and Evaluation Center for Methods in Environmental Medicine (Zentrale Erfassungs- und Bewertungsstelle fuer umweltmedizinische Methoden, ZEBUM) at the Robert Koch Institute. (orig.) [de

  13. Good manufacturing practice - quality assurance programs

    International Nuclear Information System (INIS)

    Masefield, John; Thompson, Steven

    1986-01-01

    The concept of good manufacturing practice (GMP) in the medical device industry requires the use of controlled methods and equipment in performing each step in the device manufacturing process. Quality assurance programs are used to maintain compliance with GMP requirements by prescribing the operating and control procedures to be used. The specific elements of a quality assurance program for the radiation sterilization of medical devices are described. (author)

  14. Quality assurance in medical laboratories

    International Nuclear Information System (INIS)

    Boroviczeny, K.G. von; Merten, R.; Merten, U.P.

    1987-01-01

    The book presents a comprehensive and specified survey of the quality assurance measures and methods applied in medical laboratories in the pre-analytical phase and in the analytical and post-analytical phases. It also gives information on computer-aided procedures, cost-benefit analyses in this field, and on official requirements and standards in the fields of clinical chemistry, hematology, immunology and microbiology, and equipment testing and inspection. One chapter of the book particularly deals with quality assurance for radioimmunological in-vitro analyses. With 112 figs., 337 tabs [de

  15. Ontario's Quality Assurance Framework: A Critical Response

    Science.gov (United States)

    Heap, James

    2013-01-01

    Ontario's Quality Assurance Framework (QAF) is reviewed and found not to meet all five criteria proposed for a strong quality assurance system focused on student learning. The QAF requires a statement of student learning outcomes and a method and means of assessing those outcomes, but it does not require that data on achievement of intended…

  16. Quality assurance program

    International Nuclear Information System (INIS)

    1977-07-01

    This topical report describes the Gibbs and Hill Quality Assurance Program and sets forth the methods to be followed in controlling quality-related activities performed by Gibbs and Hill and its contractors. The program is based on company experience in nuclear power and related work, and defines a system found effective in providing independent control of quality-related functions and documentation. The scope of the report covers activities involving nuclear safety-related structures, systems, and components covered by Gibbs and Hill' contractual obligation to the Utility Owner for each project

  17. Software Quality Assurance Metrics

    Science.gov (United States)

    McRae, Kalindra A.

    2004-01-01

    Software Quality Assurance (SQA) is a planned and systematic set of activities that ensures conformance of software life cycle processes and products conform to requirements, standards and procedures. In software development, software quality means meeting requirements and a degree of excellence and refinement of a project or product. Software Quality is a set of attributes of a software product by which its quality is described and evaluated. The set of attributes includes functionality, reliability, usability, efficiency, maintainability, and portability. Software Metrics help us understand the technical process that is used to develop a product. The process is measured to improve it and the product is measured to increase quality throughout the life cycle of software. Software Metrics are measurements of the quality of software. Software is measured to indicate the quality of the product, to assess the productivity of the people who produce the product, to assess the benefits derived from new software engineering methods and tools, to form a baseline for estimation, and to help justify requests for new tools or additional training. Any part of the software development can be measured. If Software Metrics are implemented in software development, it can save time, money, and allow the organization to identify the caused of defects which have the greatest effect on software development. The summer of 2004, I worked with Cynthia Calhoun and Frank Robinson in the Software Assurance/Risk Management department. My task was to research and collect, compile, and analyze SQA Metrics that have been used in other projects that are not currently being used by the SA team and report them to the Software Assurance team to see if any metrics can be implemented in their software assurance life cycle process.

  18. Concrete and steel construction quality control and assurance

    CERN Document Server

    El-Reedy, Mohamed A

    2014-01-01

    Starting with the receipt of materials and continuing all the way through to the final completion of the construction phase, Concrete and Steel Construction: Quality Control and Assurance examines all the quality control and assurance methods involving reinforced concrete and steel structures. This book explores the proper ways to achieve high-quality construction projects, and also provides a strong theoretical and practical background. It introduces information on quality techniques and quality management, and covers the principles of quality control. The book presents all of the quality control and assurance protocols and non-destructive test methods necessary for concrete and steel construction projects, including steel materials, welding and mixing, and testing. It covers welding terminology and procedures, and discusses welding standards and procedures during the fabrication process, as well as the welding codes. It also considers the total quality management system based on ISO 9001, and utilizes numer...

  19. Quality management and quality assurance contracts

    International Nuclear Information System (INIS)

    Teichler, M.

    1991-01-01

    Quality assurance contracts belong to the most important instruments of quality management systems. As a result of such contracts, quality control is to be done not only by the buyer, but is made a task to be fulfilled by the manufacturer. The author of the article shows that quality assurance contracts do change the contractual relationship between supplier and buyer, but have no effect on economic and practical conditions. This is so because quality assurance contracts apply only to warranty claims, which play a subordinate role in the legal relationship between producer and buyer, or producer and consumer, as compared to the claims for damages arising out of the contracts. (orig.) [de

  20. Assuring quality in narrative analysis.

    Science.gov (United States)

    Bailey, P H

    1996-04-01

    Many nurse-researchers using qualitative strategies have been concerned with assuring quality in their work. The early literature reveals that the concepts of validity and reliability, as understood from the positivist perspective, are somehow inappropriate and inadequate when applied to interpretive research. More recent literature suggests that because of the positivist and interpretive paradigms are epistemologically divergent, the transfer of quality criteria from one perspective to the other is not automatic or even reasonable. The purpose of this article, therefore, is to clarify what the terms quality, trustworthiness, credibility, authenticity, and goodness mean in qualitative research findings. The process of assuring quality, validation, in qualitative research will be discussed within the context of the interpretive method, narrative analysis. A brief review of quality in narrative analysis nursing research will also be presented.

  1. Quality-Assurance Program Plan

    International Nuclear Information System (INIS)

    Kettell, R.A.

    1981-05-01

    This Quality Assurance Program Plan (QAPP) is provided to describe the Quality Assurance Program which is applied to the waste management activities conducted by AESD-Nevada Operations at the E-MAD Facility located in Area 25 of the Nevada Test Site. The AESD-Nevada Operations QAPP provides the necessary systematic and administrative controls to assure activities that affect quality, safety, reliability, and maintainability during design, procurement, fabrication, inspection, shipments, tests, and storage are conducted in accordance with established requirements

  2. 10 CFR 71.37 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 71.37 Section 71.37 Energy NUCLEAR... Package Approval § 71.37 Quality assurance. (a) The applicant shall describe the quality assurance program... quality assurance program that are applicable to the particular package design under consideration...

  3. Quality assurance programme for isotope diagnostic laboratories

    International Nuclear Information System (INIS)

    Krasznai, Istvan

    1987-01-01

    Quality assurance systems are suggested to be introduced in laboratories, in accordance with the recommendations of IAEA and WHO, taking local circumstances into consideration. It is emphasized that a quantitative enhancement of work must not endanger its quality; diagnostic information must be undistorted, reproducible, and gathered with the minimum of radiation burden. National authorities are requested to strengthen their supervision. Recommendations for quality assurance methods are given for medical isotope diagnostic laboratories. (author)

  4. Quality assurance inspections for shipping and storage containers

    Energy Technology Data Exchange (ETDEWEB)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States)

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier`s quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ``inspection tree.``The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities.

  5. Quality assurance inspections for shipping and storage containers

    International Nuclear Information System (INIS)

    Stromberg, H.M.; Roberts, G.D.; Bryce, J.H.

    1996-04-01

    This is a guide for conducting quality assurance inspections of transportation packaging and dry spent fuel storage system suppliers. (Suppliers are defined as designers, fabricators, distributors, users or owners of those packaging and storage systems.) This guide may be used during inspection to determine regulatory compliance with 10 CFR, Part 71, Subpart H; 10 CFR, Part 72, Subpart G; 10 CFR, Part 21; and supplier's quality assurance program commitments. It was developed to provide a structured, consistent approach to inspections. The guidance therein provides a framework for evaluation of transportation packaging and dry spent fuel storage systems quality assurance programs. Inspectors are provided with the flexibility to adapt the methods and concepts to meet inspection requirements for the particular facility. The method used in the guide treats each activity at a facility as a separate performance element and combines the activities within the framework of an ''inspection tree.''The method separates each performance element into several areas for inspection and identifies guidelines, based on regulatory requirements, to qualitatively evaluate each area. This guide also serves as a field manual to facilitate quality assurance inspection activities. This guide replaces an earlier one, NUREG/CR-5717 (Packing Supplier Inspection Guide). This replacement guide enhances the inspection activities for transportation packagings and adds the dry spent fuel storage system quality assurance inspection activities

  6. The challenge of quality assurance

    International Nuclear Information System (INIS)

    Simon, R.; Krischer, W.; Price, M.S.T.

    1986-01-01

    The paper presents the aims of quality assurance in the design and production of radioactive waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organisational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. The Commission of European Communities has laid emphasis on the development of appropriate test methods in its last research and development programme. First results of the work are reviewed in the context of international progress in this field. (author)

  7. Training, Quality Assurance Factors, and Tools Investigation: a Work Report and Suggestions on Software Quality Assurance

    Science.gov (United States)

    Lee, Pen-Nan

    1991-01-01

    Previously, several research tasks have been conducted, some observations were obtained, and several possible suggestions have been contemplated involving software quality assurance engineering at NASA Johnson. These research tasks are briefly described. Also, a brief discussion is given on the role of software quality assurance in software engineering along with some observations and suggestions. A brief discussion on a training program for software quality assurance engineers is provided. A list of assurance factors as well as quality factors are also included. Finally, a process model which can be used for searching and collecting software quality assurance tools is presented.

  8. Private sector delivery of health services in developing countries: a mixed-methods study on quality assurance in social franchises

    Science.gov (United States)

    2013-01-01

    Background Across the developing world health care services are most often delivered in the private sector and social franchising has emerged, over the past decade, as an increasingly popular method of private sector health care delivery. Social franchising aims to strengthen business practices through economies of scale: branding clinics and purchasing drugs in bulk at wholesale prices. While quality is one of the established goals of social franchising, there is no published documentation of how quality levels might be set in the context of franchised private providers, nor what quality assurance measures can or should exist within social franchises. The aim of this study was to better understand the quality assurance systems currently utilized in social franchises, and to determine if there are shared standards for practice or quality outcomes that exist across programs. Methods The study included three data sources and levels of investigation: 1) Self-reported program data; 2) Scoping telephone interviews; and 3) In-depth field interviews and clinic visits. Results Social Franchises conceive of quality assurance not as an independent activity, but rather as a goal that is incorporated into all areas of franchise operations, including recruitment, training, monitoring of provider performance, monitoring of client experience and the provision of feedback. Conclusions These findings are the first evidence to support the 2002 conceptual model of social franchising which proposed that the assurance of quality was one of the three core goals of all social franchises. However, while quality is important to franchise programs, quality assurance systems overall are not reflective of the evidence to-date on quality measurement or quality improvement best practices. Future research in this area is needed to better understand the details of quality assurance systems as applied in social franchise programs, the process by which quality assurance becomes a part of the

  9. Private sector delivery of health services in developing countries: a mixed-methods study on quality assurance in social franchises

    Directory of Open Access Journals (Sweden)

    Schlein Karen

    2013-01-01

    Full Text Available Abstract Background Across the developing world health care services are most often delivered in the private sector and social franchising has emerged, over the past decade, as an increasingly popular method of private sector health care delivery. Social franchising aims to strengthen business practices through economies of scale: branding clinics and purchasing drugs in bulk at wholesale prices. While quality is one of the established goals of social franchising, there is no published documentation of how quality levels might be set in the context of franchised private providers, nor what quality assurance measures can or should exist within social franchises. The aim of this study was to better understand the quality assurance systems currently utilized in social franchises, and to determine if there are shared standards for practice or quality outcomes that exist across programs. Methods The study included three data sources and levels of investigation: 1 Self-reported program data; 2 Scoping telephone interviews; and 3 In-depth field interviews and clinic visits. Results Social Franchises conceive of quality assurance not as an independent activity, but rather as a goal that is incorporated into all areas of franchise operations, including recruitment, training, monitoring of provider performance, monitoring of client experience and the provision of feedback. Conclusions These findings are the first evidence to support the 2002 conceptual model of social franchising which proposed that the assurance of quality was one of the three core goals of all social franchises. However, while quality is important to franchise programs, quality assurance systems overall are not reflective of the evidence to-date on quality measurement or quality improvement best practices. Future research in this area is needed to better understand the details of quality assurance systems as applied in social franchise programs, the process by which quality assurance

  10. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Dommke, J.; Jurgutat, H.

    1980-01-01

    During the time of planing and construction of a nuclear power plant, the following proceeding is approved: - the deliverer of a nuclear power plant provides the reports fixing the quality assurance program, it means that he is responsible to write the safety analysis report, the specifications for the erection of the components, the working manuals and specifications for testing (eg nondestr. testing) - the manufacturing of components or systems will be controlled by an own independent quality assurance group, provided that this group was checked by the quality assurance group of the applicant - the TUeV with its independent assessors will fix the requirements relating to quality assurance in its assessment. On this basis the examination of the applicants specifications, working manuals, testing specifications will be done. The efficiency of quality assurance at the manufacturer and at the applicant will be checked by the TUeV specialists by considering specifications of modifications, repairs or tolerances. A mean point of the quality assurance in Germany is the dynamic adjustment, of an action on the latest state of engineering or science. If there exists a change of rules or guidelines, the quality assurance requirements have to be fit on this state in so far as it is feasible from the technical point of view. (orig./RW)

  11. Chapter 8: Quality assurance

    International Nuclear Information System (INIS)

    2001-01-01

    The main efforts of Nuclear Regulatory Authority of the Slovak Republic (UJD) have been focused on inspection of quality assurance programmes of Slovak Power Stations, plc. and its daughter companies at Bohunice and Mochovce. Two quality assurance inspections in the area of periodical in service inspections (V-2 units) and tests of selected equipment (NPP V-2 units) and operation control (V-1 units) has been performed at NPPs Bohunice. One violation of decree on quality assurance of selected equipment has been found in the area of documentation archiving. The inspection concerning the implementation of quality assurance programme for operation of NPP Mochovce in the area of operation control has been performed focused on safety aspects of operation, operational procedures, control of operational events and feedback from operational experience. The results of this inspection were positive. Inspection of implementation of quality assurance programme for operation of radioactive waste repository (RU RAW) at the Mochovce location has been performed focused on receiving of containers, with radioactive wastes, containers handling, radiation monitoring, activities of documentation control and radiation protection at the repository site. No serious deficiencies have been found out. Also one inspection of experimental nuclear installations of VUJE Trnava at Jaslovske Bohunice site has been performed focused on procurement control, quality audits, documentation and quality records control when performing activities at experimental nuclear installations. The activity on development of internal quality assurance system continued. The implementation of this system will assure quality and effective fulfilment enlarged tasks of UJD with limited resources for its activity. The analyses of possible use of existing internal administrative control documentation as a basis for future quality system procedures was performed in co-operation with an external specialised organisation. The

  12. Quality assurance in radiodiagnosis

    International Nuclear Information System (INIS)

    Ghilardi Netto, T.; Sao Paulo Univ., Ribeirao Preto

    1983-01-01

    The following topics are dealt with: 1) the importance of the application of a quality assurance program in radiodiagnosis, with its main consequences : improvement of imaging quality, reduction of the patient expossure rate, cost reduction and 2) how to introduce the quality assurance control in the radiodiagnostic area. (M.A.) [pt

  13. Nuclear fuel quality assurance

    International Nuclear Information System (INIS)

    1976-01-01

    Full text: Quality assurance is used extensively in the design, construction and operation of nuclear power plants. This methodology is applied to all activities affecting the quality of a nuclear power plant in order to obtain confidence that an item or a facility will perform satisfactorily in service. Although the achievement of quality is the responsibility of all parties participating in a nuclear power project, establishment and implementation of the quality assurance programme for the whole plant is a main responsibility of the plant owner. For the plant owner, the main concern is to achieve control over the quality of purchased products or services through contractual arrangements with the vendors. In the case of purchase of nuclear fuel, the application of quality assurance might be faced with several difficulties because of the lack of standardization in nuclear fuel and the proprietary information of the fuel manufacturers on fuel design specifications and fuel manufacturing procedures. The problems of quality assurance for purchase of nuclear fuel were discussed in detail during the seminar. Due to the lack of generally acceptable standards, the successful application of the quality assurance concept to the procurement of fuel depends on how much information can be provided by the fuel manufacturer to the utility which is purchasing fuel, and in what form and how early this information can be provided. The extent of information transfer is basically set out in the individual vendor-utility contracts, with some indirect influence from the requirements of regulatory bodies. Any conflict that exists appears to come from utilities which desire more extensive control over the product they are buying. There is a reluctance on the part of vendors to permit close insight of the purchasers into their design and manufacturing procedures, but there nevertheless seems to be an increasing trend towards release of more information to the purchasers. It appears that

  14. RAVEN Quality Assurance Activities

    Energy Technology Data Exchange (ETDEWEB)

    Cogliati, Joshua Joseph [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-09-01

    This report discusses the quality assurance activities needed to raise the Quality Level of Risk Analysis in a Virtual Environment (RAVEN) from Quality Level 3 to Quality Level 2. This report also describes the general RAVEN quality assurance activities. For improving the quality, reviews of code changes have been instituted, more parts of testing have been automated, and improved packaging has been created. For upgrading the quality level, requirements have been created and the workflow has been improved.

  15. Measurement quality assurance

    International Nuclear Information System (INIS)

    Eisenhower, E.H.

    1988-01-01

    The quality of a radiation protection program can be no better than the quality of the measurements made to support it. In many cases, that quality is unknown and is merely implied on the basis of a calibration of a measuring instrument. If that calibration is inappropriate or is performed improperly, the measurement result will be inaccurate and misleading. Assurance of measurement quality can be achieved if appropriate procedures are followed, including periodic quality control actions that demonstrate adequate performance. Several national measurement quality assurance (MQA) programs are operational or under development in specific areas. They employ secondary standards laboratories that provide a high-quality link between the National Bureau of Standards and measurements made at the field use level. The procedures followed by these secondary laboratories to achieve MQA will be described, as well as plans for similar future programs. A growing general national interest in quality assurance, combined with strong specific motivations for MQA in the area of ionizing radiation, will provide continued demand for appropriate national programs. Such programs must, however, employ procedures that are cost effective and must be developed with participation by all affected parties

  16. Metrology's role in quality assurance

    International Nuclear Information System (INIS)

    Zeederberg, L.B.

    1982-01-01

    Metrology, the science of measurement, is playing an increasing role in modern industry as part of an on-going quality assurance programme. At Escom, quality assurance was critical during the construction of the Koeberg nuclear facility, and also a function in controlling services provided by Escom. This article deals with the role metrology plays in quality assurance

  17. Software quality assurance handbook

    Energy Technology Data Exchange (ETDEWEB)

    1990-09-01

    There are two important reasons for Software Quality Assurance (SQA) at Allied-Signal Inc., Kansas City Division (KCD): First, the benefits from SQA make good business sense. Second, the Department of Energy has requested SQA. This handbook is one of the first steps in a plant-wide implementation of Software Quality Assurance at KCD. The handbook has two main purposes. The first is to provide information that you will need to perform software quality assurance activities. The second is to provide a common thread to unify the approach to SQA at KCD. 2 figs.

  18. Quality assurance of fuel elements

    International Nuclear Information System (INIS)

    Hoerber, J.

    1980-01-01

    The quality assurance activities for reactor fuel elements are based on a quality assurance system which implies the requirements resulting from the specifications, regulations of the authorities, national standards and international rules and regulations. The quality assurance related to production of reactor fuel will be shown for PWR fuel elements in all typical fabrication steps as conversion into UO 2 -powder, pelletizing, rodmanufacture and assembling. A wide range of destructive and nondestructive techniques is applied. Quality assurance is not only verified by testing techniques but also by process monitoring by means of parameter control in production and testing procedures. (RW)

  19. Methods of Computational Intelligence in the Context of Quality Assurance in Foundry Products

    Directory of Open Access Journals (Sweden)

    Rojek G.

    2016-06-01

    Full Text Available One way to ensure the required technical characteristics of castings is the strict control of production parameters affecting the quality of the finished products. If the production process is improperly configured, the resulting defects in castings lead to huge losses. Therefore, from the point of view of economics, it is advisable to use the methods of computational intelligence in the field of quality assurance and adjustment of parameters of future production. At the same time, the development of knowledge in the field of metallurgy, aimed to raise the technical level and efficiency of the manufacture of foundry products, should be followed by the development of information systems to support production processes in order to improve their effectiveness and compliance with the increasingly more stringent requirements of ergonomics, occupational safety, environmental protection and quality. This article is a presentation of artificial intelligence methods used in practical applications related to quality assurance. The problem of control of the production process involves the use of tools such as the induction of decision trees, fuzzy logic, rough set theory, artificial neural networks or case-based reasoning.

  20. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The practice of nuclear diagnostic imaging requires an appropriate quality assurance program to attain high standards of efficiency and reliability. The International Atomic Energy Agency defines the term quality assurance as ''the closeness with which the outcome of a given procedure approaches some ideal, free from all errors and artifacts.'' The term quality control is used in reference to the specific measures taken to ensure that one particular aspect of the procedure is satisfactory. Therefore, quality assurance is a hospital-wide concept that should involve all aspects of clinical practice. Quality control is concerned with the submission of requests for procedures; the scheduling of patients; the preparation and dispensing of radiopharmaceuticals; the protection of patients, staff, and the general public against radiation hazards and accidents caused by radioactive materials or by faulty equipment; the setting up, use, and maintenance of electronic instruments; the methodology of the actual procedures; the analysis and interpretation of data; the reporting of results; and, finally, the keeping of records. The chapter discusses each of these areas

  1. Software quality assurance

    CERN Document Server

    Laporte, Claude Y

    2018-01-01

    This book introduces Software Quality Assurance (SQA) and provides an overview of standards used to implement SQA. It defines ways to assess the effectiveness of how one approaches software quality across key industry sectors such as telecommunications, transport, defense, and aerospace. * Includes supplementary website with an instructor's guide and solutions * Applies IEEE software standards as well as the Capability Maturity Model Integration for Development (CMMI) * Illustrates the application of software quality assurance practices through the use of practical examples, quotes from experts, and tips from the authors

  2. The Marshall Islands radioassay quality assurance program. An overview

    International Nuclear Information System (INIS)

    Hamilton, T.F.; Robison, W.L.; Kehl, S.; Stoker, A.C.; Conrado, C.L.

    2000-01-01

    An extensive quality assurance program to provide high quality data and assessments in support of the Marshall Islands Dose Assessment and Radioecology Program has been developed the Lawrence Livermore National Laboratory. Quality assurance objectives begin with the premise of providing integrated and cost-effective program support (to meet wide-ranging programmatic needs, scientific peer review, and build public confidence) and continue through from design and implementation of large-scale field programs, sampling and sample preparation, radiometric and chemical analyses, documentation of quality assurance/quality control practices, exposure assessments, and dose/risk assessments until publication. The basic structure of the radioassay quality assurance/quality control program can be divided into four essential elements: (1) sample and data integrity control, (2) instrument validation and calibration, (3) method performance testing, validation, development and documentation, and (4) periodic peer review and on-site assessments. While the quality assurance objectives are tailored towards a single research program and the evaluation of major exposure pathways/critical radionuclides pertinent to the Marshall Islands, quality assurance practices that are consistent with proposed criteria designed for laboratory accreditation were attempted to be developed. (author)

  3. Quality assurance in plant engineering

    International Nuclear Information System (INIS)

    Ohsumi, Morimichi

    1977-01-01

    Quality assurance is defined as the intentional and systematic activity carried out to obtain such reliability that the functions of nuclear power generating plants are demonstrated during the plant operation, and the section in charge has the role to organize, adjust and communicate so that the related sections can work smoothly. There are many documents concerning the quality assurance, such as quality assurance basic program, quality assurance manual, quality control plan and its manual and many specifications, etc. The content of the quality assurance is different for every step of plant planning such as at inquiry and order receiving, and prior to manufacturing, for example, inspection specification being decided for the material and the welded parts of classified pipings at the step of order receiving. Document management, engineering schedule and the custody of quality records are also quality assurance activities. Design management is controlled step by step; plant planning including safety analysis, overall layout plan, conceptual design of buildings, aseismatic design guide, heat balance and so on, system design mainly with system description, piping design including piping specification, standard dimensions of edge preparation, piping and valve lists, inspection manual, etc., detailed design, standardization of piping and design review, etc. are explained. The management of the intermediate between soft and hard parts consists of the quality check for material manufacturers and shipment inspection, etc. (Nakai, Y.)

  4. Develpment of quality assurance manual for fabrication of DUPIC fuel

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT.

  5. Develpment of quality assurance manual for fabrication of DUPIC fuel

    International Nuclear Information System (INIS)

    Lee, Young Gun; Lee, J. W.; Kim, S. S. and others

    2001-09-01

    The Quality Assurance Manual for the fabrication of DUPIC fuel with high quality was developed. The Quality Assurance Policy established by this manual is to assure that the DUPIC fuel element supplied to customer conform to the specified requirements of customer, applicable codes and standards. The management of KAERI is committed to implementation and maintenance of the program described by this manual. This manual describes the quality assurance program for DUPIC fuel fabrication to comply with CAN3-Z299.2-85 to the extent as needed and appropriate. This manual describes the methods which DUPIC Fuel Development Team(DFDT) personnel must follow to achieve and assure high quality of our product. This manual also describes the quality management system applicable to the activities performed at DFDT

  6. Quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Gillespie, B.M.; Gleckler, B.P.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results.

  7. Quality assurance

    International Nuclear Information System (INIS)

    Gillespie, B.M.; Gleckler, B.P.

    1995-01-01

    This section of the 1994 Hanford Site Environmental Report summarizes the quality assurance and quality control practices of Hanford Site environmental monitoring and surveillance programs. Samples are analyzed according to documented standard analytical procedures. This section discusses specific measures taken to ensure quality in project management, sample collection, and analytical results

  8. Quality Assurance in Asian Distance Education: Diverse Approaches and Common Culture

    Directory of Open Access Journals (Sweden)

    Insung Jung

    2011-10-01

    Full Text Available With the phenomenal expansion of distance education in Asia during the past three decades, there has been growing public demand for quality and accountability in distance education. This study investigates the national quality assurance systems for distance education at the higher education level in Asia with the aim of contributing to a better understanding of the current level of development of quality assurance in Asian distance education and to offer potential directions for policy makers when developing and elaborating quality assurance systems for distance education. The analysis of the existing quality assurance frameworks in the 11 countries/territories selected reveals that the level of quality assurance policy integration in the overall national quality assurance in higher education policy framework varies considerably. The purpose of quality assurance, policy frameworks, methods, and instruments in place are generally tailored to each country’s particular circumstances. There are, however, obvious commonalities that underpin these different quality assurance efforts.

  9. Quality assurance for diabetic retinopathy telescreening.

    Science.gov (United States)

    Schneider, S; Aldington, S J; Kohner, E M; Luzio, S; Owens, D R; Schmidt, V; Schuell, H; Zahlmann, G

    2005-06-01

    TOSCA was an EU-Commission supported international research project designed to develop telescreening services in diabetic retinopathy and glaucoma. This paper describes the quality assurance methods developed for the diabetic retinopathy telescreening service within the TOSCA project. The study was performed in 1895 patients with diabetes between 2000 and 2002 at diabetic retinopathy screening sites in five European countries. Data were analysed centrally. Patients attending each clinic's diabetic retinopathy screening service received standardized retinal photography. The images and associated data were transferred electronically to a remote location for grading. Each photographer uploading images and each grader downloading images for assessment was controlled by a systematic quality management approach. The quality assurance measures defined were image quality, intragrader reliability. A cockpit chart was developed for the management and presentation of relevant results and quality measures. For the intragrader reliability tests, 10% of the images were processed for a second grading. An algorithm for calculating differences between repeated gradings was developed. The assessment of image quality for the different sites showed that only 0-0.7% were unassessable. One hundred per cent agreement for both gradings was achieved in 50-85% of graded cases, depending on site and grader, and an agreement better than 95% in 71-100% of cases. A telemedicine-supported quality assurance process is practical and advantageous. The cockpit charts have proven to be useful tools when monitoring the performance of a telescreening service. Grader feedback showed high satisfaction with the quality assurance process.

  10. Application of software quality assurance methods in validation and maintenance of reactor analysis computer codes

    International Nuclear Information System (INIS)

    Reznik, L.

    1994-01-01

    Various computer codes employed at Israel Electricity Company for preliminary reactor design analysis and fuel cycle scoping calculations have been often subject to program source modifications. Although most changes were due to computer or operating system compatibility problems, a number of significant modifications were due to model improvement and enhancements of algorithm efficiency and accuracy. With growing acceptance of software quality assurance requirements and methods, a program of implementing extensive testing of modified software has been adopted within the regular maintenance activities. In this work survey has been performed of various software quality assurance methods of software testing which belong mainly to the two major categories of implementation ('white box') and specification-based ('black box') testing. The results of this survey exhibits a clear preference of specification-based testing. In particular the equivalence class partitioning method and the boundary value method have been selected as especially suitable functional methods for testing reactor analysis codes.A separate study of software quality assurance methods and techniques has been performed in this work objective to establish appropriate pre-test software specification methods. Two methods of software analysis and specification have been selected as the most suitable for this purpose: The method of data flow diagrams has been shown to be particularly valuable for performing the functional/procedural software specification while the entities - relationship diagrams has been approved to be efficient for specifying software data/information domain. Feasibility of these two methods has been analyzed in particular for software uncertainty analysis and overall code accuracy estimation. (author). 14 refs

  11. Redefining and expanding quality assurance.

    Science.gov (United States)

    Robins, J L

    1992-12-01

    To meet the current standards of excellence necessary for blood establishments, we have learned from industry that a movement toward organization-wide quality assurance/total quality management must be made. Everyone in the organization must accept responsibility for participating in providing the highest quality products and services. Quality must be built into processes and design systems to support these quality processes. Quality assurance has been redefined to include a quality planning function described as the most effective way of designing quality into processes. A formalized quality planning process must be part of quality assurance. Continuous quality improvement has been identified as the strategy every blood establishment must support while striving for error-free processing as the long-term objective. The auditing process has been realigned to support and facilitate this same objective. Implementing organization-wide quality assurance/total quality management is one proven plan for guaranteeing the quality of the 20 million products that are transfused into 4 million patients each year and for moving toward the new order.

  12. Quality assurance and quality control of nuclear engineering during construction phase

    International Nuclear Information System (INIS)

    Zhang Zhihua; Deng Yue; Liu Yaoguang; Xu Xianqi; Zhou Shan; Qian Dazhi; Zhang Yang

    2007-01-01

    The quality assurance (QA) and quality control (QC) is a very important work in the nuclear engineering. This paper starts with how to establish quality assurance system of nuclear engineering construction phase, then introduces several experiments and techniques such as the implementation of quality assurance program, the quality assurance and quality control of contractors, the quality surveillance and control of supervisory companies, quality assurance audit and surveillance of builders. (authors)

  13. Chemical analysis quality assurance at the ICPP

    International Nuclear Information System (INIS)

    Hand, R.L.

    1990-01-01

    This document discusses the chemical analysis quality assurance program at the ICPP which involves records management, analytical methods quality control, analysis procedures and training and qualification. Since 1979, the major portion of the quality assurance program has been implemented on a central analytical computer system. The individual features provided by the system are storage, retrieval, and search capabilities over all general request and sample analysis information, automatic method selection for all process streams, automation of all method calculations, automatic assignment of bias and precision estimates at all analysis levels, with-method-use requalification, untrained or unqualified analyst method lockout, statistical testing of all process stream results for replicate agreement, automatic testing of process results against pre- established operating, safety, or failure limits at varying confidence levels, and automatic transfer and report of all analysis data plus all statistical testing to the Production Department

  14. Quality Management, Quality Assurance and Quality Control in Blood Establishments

    OpenAIRE

    Bolbate, N

    2008-01-01

    Quality terms and the roots of the matter are analyzed according to European Committee’s recommendations. Essence of process and product quality control as well as essence of quality assurance is described. Quality system’s structure including quality control, quality assurance and management is justified in the article.

  15. An approach to total quality assurance

    International Nuclear Information System (INIS)

    Archer, L.G.

    1976-01-01

    Total Quality Assurance must be based on amalgamating three quality functions: effective quality control, competent inspection, and regularly audited Quality Assurance programmes. In applying these functions the fuel supplier must regard each of his sub-contractors as part of his own works and ensure a common policy of motivated Quality Assurance throughout his own works and those of his suppliers. (author)

  16. 40 CFR 31.45 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 31.45 Section 31.45... Requirements Reports, Records, Retention, and Enforcement § 31.45 Quality assurance. If the grantee's project... quality assurance practices consisting of policies, procedures, specifications, standards, and...

  17. [Quality assurance in human genetic testing].

    Science.gov (United States)

    Stuhrmann-Spangenberg, Manfred

    2015-02-01

    Advances in technical developments of genetic diagnostics for more than 50 years, as well as the fact that human genetic testing is usually performed only once in a lifetime, with additional impact for blood relatives, are determining the extraordinary importance of quality assurance in human genetic testing. Abidance of laws, directives, and guidelines plays a major role. This article aims to present the major laws, directives, and guidelines with respect to quality assurance of human genetic testing, paying careful attention to internal and external quality assurance. The information on quality assurance of human genetic testing was obtained through a web-based search of the web pages that are referred to in this article. Further information was retrieved from publications in the German Society of Human Genetics and through a PubMed-search using term quality + assurance + genetic + diagnostics. The most important laws, directives, and guidelines for quality assurance of human genetic testing are the gene diagnostics law (GenDG), the directive of the Federal Medical Council for quality control of clinical laboratory analysis (RiliBÄK), and the S2K guideline for human genetic diagnostics and counselling. In addition, voluntary accreditation under DIN EN ISO 15189:2013 offers a most recommended contribution towards quality assurance of human genetic testing. Legal restraints on quality assurance of human genetic testing as mentioned in § 5 GenDG are fulfilled once RiliBÄK requirements are followed.

  18. 7 CFR 652.7 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 6 2010-01-01 2010-01-01 false Quality assurance. 652.7 Section 652.7 Agriculture... assurance. (a) NRCS will review, in consultation with the Farm Service Agency, as appropriate, the quality... information obtained through its quality assurance process, documentation submitted by the technical service...

  19. 10 CFR 76.93 - Quality assurance.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance. 76.93 Section 76.93 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) CERTIFICATION OF GASEOUS DIFFUSION PLANTS Safety § 76.93 Quality assurance. The Corporation shall establish, maintain, and execute a quality assurance program satisfying each of...

  20. Quality Assurance of Ultrasonic Diagnosis in Breast

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Kim, Hong Dae [Hallym University, Kangnam Sacred Heart Hospital, Seoul (Korea, Republic of)

    2006-06-15

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  1. Quality Assurance of Ultrasonic Diagnosis in Breast

    International Nuclear Information System (INIS)

    Chung, Soo Young; Kim, Hong Dae

    2006-01-01

    Sonography is a subjective diagnostic method which is highly dependent on the experience of the operator and the equipment quality which requires real-time adjustments. Breast screening examination currently consists of clinical examination and mammography. Breast sonography, either supplementary to mammography or independently, is indicated for the dense breast, especially in younger women. Breast sonography is especially applicable for Korean women because of the denser breast parenchyma and the approximately 10-year younger incidence rate of breast cancer of Korean women compared to western women. To avoid unnecessary breast biopsy because of the high rate of false positive lesions in breast parenchyma, which is different from other body organs such as the liver or the kidney, a quality assurance program for breast sonography is essential. The quality assurance of breast ultrasound involves quality assurance of the equipment, imaging display and acquisition of clinical images, personnel qualifications and other aspects such as unification of lexicon, guideline of diagnostic examination and reporting system; US BI-RAD reporting system, assessment items and organization, education program, medical audit, certification issues, and medicolegal issues. A breast sonographic quality assurance system should be established before a scheme to initiate governmental medical insurance for breast sonography

  2. 10 CFR 63.142 - Quality assurance criteria.

    Science.gov (United States)

    2010-01-01

    ... planned and periodic audits to verify compliance with all aspects of the quality assurance program and to... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance criteria. 63.142 Section 63.142 Energy... REPOSITORY AT YUCCA MOUNTAIN, NEVADA Quality Assurance § 63.142 Quality assurance criteria. (a) Introduction...

  3. Nuclear quality assurance operating philosophy: A quality-oriented approach

    International Nuclear Information System (INIS)

    Corcoran, W.R.; Geiger, J.E.; Heibel, R.E.; Cotton, J.B.; Sabol, A.R.

    1992-01-01

    Quality assurance programs have been part of the nuclear utility management process since the publication of the draft of 10CFR50 Appendix B in the late 1960s. The unwritten operational philosophy of nuclear quality assurance organizations focused on compliance with federal regulations. Adverse experiences, including operational events and extended shutdowns, prompted the gradual adoption of isolated practices extending beyond compliance orientation. These practices have an orientation that accommodates a definition of quality, a perspective of the role of nuclear quality assurance organizations in the overall concept of defense-in-depth, a definition of the segments of the nuclear quality assurance mission, and recent advances in the understanding of self-assessment. Observation of these practices at various nuclear utilities resulted in a syntheses of practices and approaches into a coherent quality-oriented nuclear quality assurance operating philosophy that is not totally adopted at any one utility

  4. BYU Food Quality Assurance Laboratory

    Data.gov (United States)

    Federal Laboratory Consortium — The Quality Assurance Lab is located in the Eyring Science Center in the department of Nutrition, Dietetics, and Food Science. The Quality Assurance Lab has about 10...

  5. 30 CFR 74.9 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 74.9 Section 74.9 Mineral... DUST SAMPLING DEVICES Requirements for Continuous Personal Dust Monitors § 74.9 Quality assurance. (a) General requirements. The applicant shall establish and maintain a quality control system that assures...

  6. 40 CFR 30.54 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 1 2010-07-01 2010-07-01 false Quality assurance. 30.54 Section 30.54... NON-PROFIT ORGANIZATIONS Post-Award Requirements Reports and Records § 30.54 Quality assurance. If the... data generation, the grantee shall develop and implement quality assurance practices consisting of...

  7. [Quality assurance in occupational health services].

    Science.gov (United States)

    Michalak, J

    1996-01-01

    The general conditions influencing the quality assurance and audit in Polish occupational health services are presented. The factors promoting or hampering the implementation of quality assurance and audits are also discussed. The major influence on the transformation of Polish occupational health services in exorted by employers who are committed to cover the costs of the obligatory prophylactic examination of their employees. This is the factor which also contributes to the improvement of quality if services. The definitions of the most important terms are reviewed to highlight their accordance with the needs of occupational health services in Poland. The examples of audit are presented and the elements of selected methods of auditing are suggested to be adopted in Poland.

  8. Software quality assurance - seven years experience

    International Nuclear Information System (INIS)

    Malsbury, J.A.

    1987-01-01

    This paper describes seven years experience with software quality assurance at PPPL. It covers the early attempts of 1980 and 1981 to establish software quality assurance; the first attempt of 1982 to develop a complete software quality assurance plan; the significant modifications of this plan in 1985; and the future. In addition, the paper describes the role of the Quality Assurance organization within each plan. The scope of this paper is limited to discussions of the software development procedures used in the seven year period. Other software quality topics, such as configuration control or problem identification and resolution, are not discussed

  9. The successful Chief Executive Officer understands quality assurance

    International Nuclear Information System (INIS)

    Hedges, D.

    1984-01-01

    The successful Chief Executive Officer (CEO) will have recognized the benefits of, and have implemented, a total quality assurance program. The quality assurance program will be adequately defined in policies and procedures such that managers and supervisors of each organizational element understand their primary and supporting roles in carrying out an effective quality assurance program. The traditional practice of having all quality assurance activities reside in a quality assurance organization will have been cast aside. Instead, the quality assurance activities necessary to achieve and assure the quality of the desired end product will have been defined and assigned to responsible organization elements. The quality assurance organization's primary role will be to define the total quality assurance program, insure that the achieving and assuring functions are assigned in policies and procedures, conduct training necessary to have management and supervisors understand the total quality assurance program, measure the effectiveness of the program and feedback measurement data for improvements in the program. The successful CEO will have implemented a quality assurance program that provides for a graded approach for application of the program based upon the importance of the intended use of the product or service. The successful CEO will rely heavily on the scheduled progress reports and assessments to measure the pulse of his organization's successes and improvement needs. This paper will describe suggested approaches for the Quality Assurance Manager to implement a quality assurance program which results in his corporation's CEO being a supporter of and a driving force in the implementation of the quality assurance program

  10. Transuranic Waste Characterization Quality Assurance Program Plan

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-30

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes.

  11. Transuranic Waste Characterization Quality Assurance Program Plan

    International Nuclear Information System (INIS)

    1995-01-01

    This quality assurance plan identifies the data necessary, and techniques designed to attain the required quality, to meet the specific data quality objectives associated with the DOE Waste Isolation Pilot Plant (WIPP). This report specifies sampling, waste testing, and analytical methods for transuranic wastes

  12. Data quality assurance in monitoring of wastewater quality: Univariate on-line and off-line methods

    DEFF Research Database (Denmark)

    Alferes, J.; Poirier, P.; Lamaire-Chad, C.

    To make water quality monitoring networks useful for practice, the automation of data collection and data validation still represents an important challenge. Efficient monitoring depends on careful quality control and quality assessment. With a practical orientation a data quality assurance proce...

  13. Principles and Practices for Quality Assurance and Quality Control

    Science.gov (United States)

    Jones, Berwyn E.

    1999-01-01

    Quality assurance and quality control are vital parts of highway runoff water-quality monitoring projects. To be effective, project quality assurance must address all aspects of the project, including project management responsibilities and resources, data quality objectives, sampling and analysis plans, data-collection protocols, data quality-control plans, data-assessment procedures and requirements, and project outputs. Quality control ensures that the data quality objectives are achieved as planned. The historical development and current state of the art of quality assurance and quality control concepts described in this report can be applied to evaluation of data from prior projects.

  14. Thoughts on Internal and External Quality Assurance

    Science.gov (United States)

    Zhang, Jianxin

    2012-01-01

    Quality assurance of higher education is made up of two parts: internal quality assurance (IQA) and external quality assurance (EQA). Both belong to a union of the coexistence and balance of yin and yang. But in reality there exists a paradox of "confusion of quality assurance (QA) subject consciousness, singularity of social QA and lack of QA…

  15. Role of Informatics in Patient Safety and Quality Assurance.

    Science.gov (United States)

    Nakhleh, Raouf E

    2015-06-01

    Quality assurance encompasses monitoring daily processes for accurate, timely, and complete reports in surgical pathology. Quality assurance also includes implementation of policies and procedures that prevent or detect errors in a timely manner. This article presents uses of informatics in quality assurance. Three main foci are critical to the general improvement of diagnostic surgical pathology. First is the application of informatics to specimen identification with lean methods for real-time statistical control of specimen receipt and processing. Second is the development of case reviews before sign-out. Third is the development of information technology in communication of results to assure treatment in a timely manner. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. The application of statistical process control in linac quality assurance

    International Nuclear Information System (INIS)

    Li Dingyu; Dai Jianrong

    2009-01-01

    Objective: To improving linac quality assurance (QA) program with statistical process control (SPC) method. Methods: SPC is applied to set the control limit of QA data, draw charts and differentiate the random and systematic errors. A SPC quality assurance software named QA M ANAGER has been developed by VB programming for clinical use. Two clinical cases are analyzed with SPC to study daily output QA of a 6MV photon beam. Results: In the clinical case, the SPC is able to identify the systematic errors. Conclusion: The SPC application may be assistant to detect systematic errors in linac quality assurance thus it alarms the abnormal trend to eliminate the systematic errors and improves quality control. (authors)

  17. Application of quality assurance to MC and A systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Application of the principles of quality assurance to MC and A has been done at DOE's Savannah River Operations Office. The principles were applied to the functions within the MC and A Branch, including both the functions used to operate the Branch and those used to review the MC and A activities of DOE/SR's contractor. The purpose of this paper is to discuss that application of quality assurance and to show how the principles of quality assurance relate to the functions of a MC and A system, for both a DOE field office and a contractor. The principles (presented as requirements from the NQA-1 standard) are briefly discussed, a method for applying quality assurance is outlined, application at DOE/SR is shown, and application to a contractor's MC and A system is discussed

  18. Quality assurance management policies and requirements

    International Nuclear Information System (INIS)

    1985-10-01

    The purpose of this document is to: set forth overall, integrated quality assurance management policies and requirements for the entire Civilian Radioactive Waste Management Program; define management responsibilities for assuring quality; and provide a general framework for the development of more detailed quality assurance management policies and requirements by program, project, and contractor organizations

  19. Quality assurance in the nuclear industry

    International Nuclear Information System (INIS)

    Knoedler, D.

    1978-01-01

    Quality assurance is the sum of all activities systematically planned, practiced, and controlled with the aim to assure the quality of deliveries and performances. This assurance today covers all phases of activities, from the planning (including a determination of the required and necessary quality characteristics) to the start-up of a plant. (orig./RW) [de

  20. 40 CFR 75.21 - Quality assurance and quality control requirements.

    Science.gov (United States)

    2010-07-01

    ... quality assurance audit or any other audit, the system is out-of-control. The owner or operator shall... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Quality assurance and quality control... assurance and quality control requirements. (a) Continuous emission monitoring systems. The owner or...

  1. Software Quality Assurance Audits Guidebooks

    Science.gov (United States)

    1990-01-01

    The growth in cost and importance of software to NASA has caused NASA to address the improvement of software development across the agency. One of the products of this program is a series of guidebooks that define a NASA concept of the assurance processes that are used in software development. The Software Assurance Guidebook, NASA-GB-A201, issued in September, 1989, provides an overall picture of the NASA concepts and practices in software assurance. Second level guidebooks focus on specific activities that fall within the software assurance discipline, and provide more detailed information for the manager and/or practitioner. This is the second level Software Quality Assurance Audits Guidebook that describes software quality assurance audits in a way that is compatible with practices at NASA Centers.

  2. Private sector delivery of health services in developing countries: a mixed-methods study on quality assurance in social franchises.

    Science.gov (United States)

    Schlein, Karen; De La Cruz, Anna York; Gopalakrishnan, Tisha; Montagu, Dominic

    2013-01-03

    Across the developing world health care services are most often delivered in the private sector and social franchising has emerged, over the past decade, as an increasingly popular method of private sector health care delivery. Social franchising aims to strengthen business practices through economies of scale: branding clinics and purchasing drugs in bulk at wholesale prices. While quality is one of the established goals of social franchising, there is no published documentation of how quality levels might be set in the context of franchised private providers, nor what quality assurance measures can or should exist within social franchises. The aim of this study was to better understand the quality assurance systems currently utilized in social franchises, and to determine if there are shared standards for practice or quality outcomes that exist across programs. The study included three data sources and levels of investigation: 1) Self-reported program data; 2) Scoping telephone interviews; and 3) In-depth field interviews and clinic visits. Social Franchises conceive of quality assurance not as an independent activity, but rather as a goal that is incorporated into all areas of franchise operations, including recruitment, training, monitoring of provider performance, monitoring of client experience and the provision of feedback. These findings are the first evidence to support the 2002 conceptual model of social franchising which proposed that the assurance of quality was one of the three core goals of all social franchises. However, while quality is important to franchise programs, quality assurance systems overall are not reflective of the evidence to-date on quality measurement or quality improvement best practices. Future research in this area is needed to better understand the details of quality assurance systems as applied in social franchise programs, the process by which quality assurance becomes a part of the organizational culture, and the components of

  3. Proactive quality assurance in environmental research

    International Nuclear Information System (INIS)

    Flanagan, J.B.; Kulkarni, S.V.; Wasson, S.J.; Ford, J.S.; Harmon, D.L.

    1991-01-01

    The Quality Assurance policy of the US Environmental Protection Agency (EPA) stipulates that every project involving environmentally related monitoring, measurements, and data collection activities must have a written and approved quality assurance project plan (QAPjP). A QAPjP is a written document which presents, in specific terms, the policies, organizations, objectives, functional activities, and the quality assurance/quality control activities designed to achieve the quality goals for data collection. In the research studies involving novel or non-routine measurements that use unvalidated methods, measurement quality goals are often difficult or impossible to specify at the beginning of the project for which a QAPjP must be written. Furthermore, it may not be possible for the QAPjP reviewers to evaluate the reasonableness of these goals without initial information about the system under study. For the project to evaluate chlorofluorocarbon for recycling from domestic refrigerators, the QAPjP incorporated standard analytical techniques used by industry. These techniques did not provide accuracy and precision or other validation information. For the initial version of the QAPjP, measurement quality goals were assigned based on limited experience. Quality assurance support was called upon to evaluate the performance of the measurement system for this project through a series of audits. The performance evaluation audits necessitated designing novel audit materials and sample delivery techniques. Continued interaction is necessary between the project and QA teams to permit evolution of reasonable data quality indicators for meaningful assessment of data quality. By treating the QAPjP as a living document that is updated and amended as more knowledge of a system is obtained, AQ becomes an integral part of the research program. This results in a greater understanding of the system under study

  4. 40 CFR 160.35 - Quality assurance unit.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Quality assurance unit. 160.35 Section... LABORATORY PRACTICE STANDARDS Organization and Personnel § 160.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for monitoring each study to assure...

  5. 2. Product quality control and assurance system

    International Nuclear Information System (INIS)

    1990-01-01

    Product quality control and assurance are dealt with in relation to reliability in nuclear power engineering. The topics treated include product quality control in nuclear power engineering, product quality assurance of nuclear power plant equipment, quality assurance programs, classification of selected nuclear power equipment, and standards relating to quality control and assurance and to nuclear power engineering. Particular attention is paid to Czechoslovak and CMEA standards. (P.A.). 2 figs., 1 tab., 12 refs

  6. Managerial attitude toward quality assurance

    International Nuclear Information System (INIS)

    Kirschenmann, H.J.

    1983-01-01

    This paper will present what relationships exist between the attitude toward quality assurance and the variables of training and experience on the part of managers within the nuclear power industry. Managerial attitude toward quality assurance was measured via questionnaires submitted to managers within architect-engineering, nuclear steam supplier, and constructor firms throughout the United States. The data from the completed questionnaires were statistically analyzed using the chi-square test and conclusions were drawn. Additional study results related to major factors for positive and negative attitudes toward quality assurance will be presented

  7. Internal Quality Assurance--Enhancing Quality Culture. ENQA Workshop Report 16

    Science.gov (United States)

    ENQA (European Association for Quality Assurance in Higher Education), 2010

    2010-01-01

    The European Association for Quality Assurance in Higher Education (ENQA), in cooperation with the Quality Assurance Agency (QAA, UK), organised a seminar on theme "Internal Quality Assurance--Enhancing quality culture" which was held on 8-9 June, 2010 in London, United Kingdom. The seminar marked the fourth annual meeting of the ENQA…

  8. Concepts of nuclear quality assurance

    International Nuclear Information System (INIS)

    Randers, G.; Morris, P.A.; Pomeroy, D.

    1976-01-01

    While the safety record of the nuclear industry continues to be excellent, the forced outage rates for recent years continue to be 15% or more. Quality assurance, therefore, needs to be applied not only to nuclear safety matters, but to the goals of increased productivity and reduced construction and operating costs. Broadening the application of the general concept of quality assurance in this way leads to the introduction of reliability technology. The total activity might better be called reliability assurance. That effective quality assurance systems do pay off is described by examples from the utility industry, from a manufacturer of instruments and systems and from the experience of Westinghouse Electric Company's manufacturing divisions. The special situation of applying quality assurance to nuclear fuel is discussed. Problems include the lack of a fully developed regulatory policy in this area, incomplete understanding of the mechanism for pellet-clad interaction failures, incomplete access to manufacturers design and process information, inability to make desirable changes on a timely basis and inadequate feedback of irradiation experience. (author)

  9. Quality management and quality assurance

    International Nuclear Information System (INIS)

    Pieroni, N.

    1991-01-01

    The main common difficulties are presented found in the implementation of effective Quality Management and Quality Assurance Programmes, based on the recommendations of the IAEA International Nuclear Safety Advisory Group, the information collected by the IAEA experts participating in its meetings, and the results of the IAEA Operational Safety Review Team missions. The difficulties were identified in several areas. The most relevant root causes can be characterized as lack of understanding of quality principles and difficulty in implementation by the responsible management. The IAEA programme is described attempting to provide advice and support in the implementation of an effective quality programme through a number of activities including: preparation of practical guidelines, training programmes for management personnel, assistance in building up qualified manpower, and promoting the quest for excellence through the exchange of experience in the implementation of effective Quality Management and Quality Assurance Programmes in nuclear power plants with good performance records. (Z.S.)

  10. Modernization of software quality assurance

    Science.gov (United States)

    Bhaumik, Gokul

    1988-01-01

    The customers satisfaction depends not only on functional performance, it also depends on the quality characteristics of the software products. An examination of this quality aspect of software products will provide a clear, well defined framework for quality assurance functions, which improve the life-cycle activities of software development. Software developers must be aware of the following aspects which have been expressed by many quality experts: quality cannot be added on; the level of quality built into a program is a function of the quality attributes employed during the development process; and finally, quality must be managed. These concepts have guided our development of the following definition for a Software Quality Assurance function: Software Quality Assurance is a formal, planned approach of actions designed to evaluate the degree of an identifiable set of quality attributes present in all software systems and their products. This paper is an explanation of how this definition was developed and how it is used.

  11. Internet of Things: Current Challenges in the Quality Assurance and Testing Methods

    OpenAIRE

    Bures, Miroslav; Cerny, Tomas; Ahmed, Bestoun S.

    2018-01-01

    Contemporary development of the Internet of Things (IoT) technology brings a number of challenges in the Quality Assurance area. Current issues related to security, user's privacy, the reliability of the service, interoperability, and integration are discussed. All these create a demand for specific Quality Assurance methodology for the IoT solutions. In the paper, we present the state of the art of this domain and we discuss particular areas of system testing discipline, which is not covered...

  12. Quality assurance in nuclear medicine

    International Nuclear Information System (INIS)

    Paras, P.

    1978-01-01

    Quality assurance practices must be followed throughout the entire nuclear medicine process, from the initial decision to perform a particular procedure, through the interpretation and reporting of the results. The various parameters that can be defined and measured in each area must be monitored by quality control tests to assure the excellence of the total nuclear medicine process. The presentation will discuss each of the major areas of nuclear medicine quality control and their interaction as a part of the entire system. Quality control testing results and recommendations for measurements of radioactivity distribution will be described with emphasis on imaging equipment and dose calibrating instrumentation. The role of the health physicist in a quality assurance program will be stressed. (author)

  13. IAEA code and safety guides on quality assurance

    International Nuclear Information System (INIS)

    Raisic, N.

    1980-01-01

    In the framework of its programme in safety standards development, the IAEA has recently published a Code of Practice on Quality Assurance for Safety in Nuclear Power Plants. The Code establishes minimum requirements for quality assurance which Member States should use in the context of their own nuclear safety requirements. A series of 10 Safety Guides which describe acceptable methods of implementing the requirements of specific sections of the Code are in preparation. (orig.)

  14. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    2006-01-01

    The WMG QAP is an integral part of a management system designed to ensure that WMG activities are planned, performed, documented, and verified in a manner that assures a quality product. A quality product is one that meets all waste acceptance criteria, conforms to all permit and regulatory requirements, and is accepted at the offsite treatment, storage, and disposal facility. In addition to internal processes, this QA Plan identifies WMG processes providing oversight and assurance to line management that waste is managed according to all federal, state, and local requirements for waste generator areas. A variety of quality assurance activities are integral to managing waste. These QA functions have been identified in the relevant procedures and in subsequent sections of this plan. The WMG QAP defines the requirements of the WMG quality assurance program. These requirements are derived from Department of Energy (DOE) Order 414.1C, Quality Assurance, Contractor Requirements Document, the LBNL Operating and Assurance Program Plan (OAP), and other applicable environmental compliance documents. The QAP and all associated WMG policies and procedures are periodically reviewed and revised, as necessary, to implement corrective actions, and to reflect changes that have occurred in regulations, requirements, or practices as a result of feedback on work performed or lessons learned from other organizations. The provisions of this QAP and its implementing documents apply to quality-affecting activities performed by the WMG; WMG personnel, contractors, and vendors; and personnel from other associated LBNL organizations, except where such contractors, vendors, or organizations are governed by their own WMG-approved QA programs

  15. Quality assurance programme for screen film mammography

    International Nuclear Information System (INIS)

    2009-01-01

    The application of radiation in human health, for both the diagnosis and treatment of disease, is an important component of the work of the IAEA. In the area of diagnostic radiology, this work is focused on quality assurance methods to both the promotion of the effective use of radiation for diagnostic outcome, through achieving and maintaining appropriate image quality, and also on dose determination to allow the monitoring and reduction of dose to the patient. In response to heightened awareness of the importance of patient dose contributed by radiology procedures, the IAEA published Dosimetry in Diagnostic Radiology: An International Code of Practice (Technical Reports Series No. 457) in 2007, to form a basis for patient dose determination for the Member States. Further to this, it is recognized that for complex diagnostic procedures, such as mammography, a detailed guidance document is required to give the professionals in the clinical centre the knowledge necessary to assess the patient dose, as well as to ensure that the procedure gives the maximal patient benefit possible. It is well documented that without the implementation of a quality culture and a systematic quality assurance programme with appropriate education, the detection of breast cancer cannot be made at an early enough stage to allow effective curative treatment to be undertaken. Currently there are a number of established quality assurance protocols in mammography from national and regional institutions, however, many of these protocols are distinctive and so a harmonized approach is required. This will allow the Member States to facilitate quality assurance in mammography in a standardized way which will also facilitate the introduction of national quality assurance programmes that are needed to underpin effective population screening programmes for breast cancer. Development of a quality assurance document for screen film mammography was started in 2005 with the appointment of a drafting

  16. A conceptual competitive intelligence quality assurance model

    Directory of Open Access Journals (Sweden)

    Tshilidzi Eric Nenzhelele

    2015-12-01

    Full Text Available Competitive Intelligence (CI improves the quality of product and service, decision-making and it improves quality of life. However, it has been established that decision makers are not happy about the quality of CI. This is because enterprises fail in quality assurance of CI. It has been concluded that most enterprises are clueless concerning CI quality assurance. Studies that previously attempted to resolve CI quality problem were limited in scope and focused too much on the quality of information than the overall CI quality. The purpose of this study is to propose a conceptual CI quality assurance model which will help in quality assurance of CI. The research was qualitative in nature and used content analysis.

  17. Project Specific Quality Assurance Plan

    International Nuclear Information System (INIS)

    Pedersen, K.S.

    1995-01-01

    This Quality Assurance Project Plan (QAPP) identifies the Westinghouse Hanford Co. (WHC) Quality Assurance (QA) program requirements for all contractors involved in the planning and execution of the design, construction, testing and inspection of the 200 Area Effluent BAT/AKART Implementation, Project W-291

  18. [Quality assurance in interventional cardiology].

    Science.gov (United States)

    Gülker, H

    2009-10-01

    Quality assurance in clinical studies aiming at approval of pharmaceutical products is submitted to strict rules, controls and auditing regulations. Comparative instruments to ensure quality in diagnostic and therapeutic procedures are not available in interventional cardiology, likewise in other fields of cardiovascular medicine. Quality assurance simply consists of "quality registers" with basic data not externally controlled. Based on the experiences of clinical studies and their long history of standardization it is assumed that these data may be severely flawed thus being inappropriate to set standards for diagnostic and therapeutic strategies. The precondition for quality assurance are quality data. In invasive coronary angiography and intervention medical indications, the decision making process interventional versus surgical revascularization, technical performance and after - care are essential aspects affecting quality of diagnostics and therapy. Quality data are externally controlled data. To collect quality data an appropriate infrastructure is a necessary precondition which is not existent. For an appropriate infrastructure investments have to be done both to build up as well as to sustain the necessary preconditions. As long as there are no infrastructure and no investments there will be no "quality data". There exist simply registers of data which are not proved to be a basis for significant assurance and enhancement in quality in interventional coronary cardiology. Georg Thieme Verlag KG Stuttgart, New York.

  19. 222-S Laboratory Quality Assurance Plan. Revision 1

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This Quality Assurance Plan provides,quality assurance (QA) guidance, regulatory QA requirements (e.g., 10 CFR 830.120), and quality control (QC) specifications for analytical service. This document follows the U.S Department of Energy (DOE) issued Hanford Analytical Services Quality Assurance Plan (HASQAP). In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. Quality assurance elements required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAMS-004) and Interim Guidelines and Specifications for Preparing Quality Assurance Project Plans (QAMS-005) from the US Environmental Protection Agency (EPA) are covered throughout this document. A quality assurance index is provided in the Appendix A. This document also provides and/or identifies the procedural information that governs laboratory operations. The personnel of the 222-S Laboratory and the Standards Laboratory including managers, analysts, QA/QC staff, auditors, and support staff shall use this document as guidance and instructions for their operational and quality assurance activities. Other organizations that conduct activities described in this document for the 222-S Laboratory shall follow this QA/QC document

  20. Quality assurance in radiation processing

    International Nuclear Information System (INIS)

    Noriah Mod Ali

    2002-01-01

    The growth of the radiation processing industries in Malaysia has presented the SSDL-MINT a new set of parameter for the Quality Assurance (QA) programs. The large massive doses of radiation required for commercial application of sterilization, cross-linking etc needs measurement method outside the scope of familiar radiation detection instruments. This requires establishment of proper calibration procedure and selection of appropriate transfer system/technique to assure adequate traceability to an international radiation standard. The benefit of accurate in-plant dosimetry for the operator, approving authority and purchaser are balanced against the extra dosimetric efforts required for good QA is presented. (Author)

  1. A method of setting limits for the purpose of quality assurance

    International Nuclear Information System (INIS)

    Sanghangthum, Taweap; Suriyapee, Sivalee; Kim, Gwe-Ya; Pawlicki, Todd

    2013-01-01

    The result from any assurance measurement needs to be checked against some limits for acceptability. There are two types of limits; those that define clinical acceptability (action limits) and those that are meant to serve as a warning that the measurement is close to the action limits (tolerance limits). Currently, there is no standard procedure to set these limits. In this work, we propose an operational procedure to set tolerance limits and action limits. The approach to establish the limits is based on techniques of quality engineering using control charts and a process capability index. The method is different for tolerance limits and action limits with action limits being categorized into those that are specified and unspecified. The procedure is to first ensure process control using the I-MR control charts. Then, the tolerance limits are set equal to the control chart limits on the I chart. Action limits are determined using the C pm process capability index with the requirements that the process must be in-control. The limits from the proposed procedure are compared to an existing or conventional method. Four examples are investigated: two of volumetric modulated arc therapy (VMAT) point dose quality assurance (QA) and two of routine linear accelerator output QA. The tolerance limits range from about 6% larger to 9% smaller than conventional action limits for VMAT QA cases. For the linac output QA, tolerance limits are about 60% smaller than conventional action limits. The operational procedure describe in this work is based on established quality management tools and will provide a systematic guide to set up tolerance and action limits for different equipment and processes. (paper)

  2. Material quality assurance risk assessment : [summary].

    Science.gov (United States)

    2013-01-01

    With the shift from quality control (QC) of materials and placement techniques : to quality assurance (QA) and acceptance over the years, the role of the Office : of Materials Technology (OMT) has been shifting towards assurance of : material quality...

  3. 48 CFR 12.208 - Contract quality assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract quality assurance... Items 12.208 Contract quality assurance. Contracts for commercial items shall rely on contractors' existing quality assurance systems as a substitute for Government inspection and testing before tender for...

  4. Quality assurance. 6. ed.

    International Nuclear Information System (INIS)

    Masing, W.

    1979-01-01

    Brief introduction to the quality sector. After some explanations of the terms of quality, feature, and defect, the article discusses the planning of quality and testing, industrial metrology, the test risk, quality assurance, quality enhancement, quality cost, and organisational problems. (RW) [de

  5. Quality assurance considerations in nuclear waste management

    International Nuclear Information System (INIS)

    Delvin, W.L.

    1982-01-01

    Proper use of quality assurance will provide the basis for an effective management control system for nuclear waste management programs. Control is essential for achieving successful programs free from costly losses and failures and for assuring the public and regulators that the environment and health and safety are being protected. The essence of quality assurance is the conscientious use of planned and systematic actions, based on selecting and applying appropriate requirements from an established quality assurance standard. Developing a quality assurance program consists of using knowledge of the technical and managerial aspects of a project to identify and evaluate risks of loss and failure and then to select appropriate quality assurance requirements that will minimize the risks. Those requirements are integrated into the project planning documents and are carried out as specific actions during the life of the project

  6. Integrating quality assurance and research and development

    International Nuclear Information System (INIS)

    Dronkers, J.J.

    1985-01-01

    Quality assurance programs cannot be transferred from one organization to another without attention to existing cultures and traditions. Introduction of quality assurance programs constitutes a significant change and represents a significant impact on the organizational structure and operational mode. Quality assurance professionals are change agents, but do not know how to be effective ones. Quality assurance as a body of knowledge and experience can only become accepted when its practitioners become familiar with their role as change agents. 8 references

  7. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    Groth, S.; Meghzifene, A.; Tatsuzaki, H.; Levin, V.; Izewska, J.

    2001-01-01

    Quality assurance in the management of a patient receiving radiation therapy and the role of the radiation oncologist and medical physicist in this process is described. The constraints on available personnel are recognised and the need for further education resources and IAEA activities in education for both groups described. IAEA activities in the clinical and dosimetric aspects and the resultant publications and education have contributed to a culture of quality assurance. (author)

  8. Quality assurance program plan for Building 324

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides an overview of the quality assurance program for Building 324. This plan supersedes the PNNL Nuclear Facilities Quality Management System Description, PNL-NF-QMSD, Revision 2, dated March 1996. The program applies to the facility safety structures, systems, and components and to activities that could affect safety structures, systems, and components. Adherence to the quality assurance program ensures the following: US Department of Energy missions and objectives are effectively accomplished; Products and services are safe, reliable, and meet or exceed the requirements and expectations of the user; Hazards to the public, to Hanford Site and facility workers, and to the environment are minimized. The format of this Quality Assurance Program Plan is structured to parallel that of 10 CFR 83 0.120, Quality Assurance Requirements

  9. Statistical methods for quality assurance basics, measurement, control, capability, and improvement

    CERN Document Server

    Vardeman, Stephen B

    2016-01-01

    This undergraduate statistical quality assurance textbook clearly shows with real projects, cases and data sets how statistical quality control tools are used in practice. Among the topics covered is a practical evaluation of measurement effectiveness for both continuous and discrete data. Gauge Reproducibility and Repeatability methodology (including confidence intervals for Repeatability, Reproducibility and the Gauge Capability Ratio) is thoroughly developed. Process capability indices and corresponding confidence intervals are also explained. In addition to process monitoring techniques, experimental design and analysis for process improvement are carefully presented. Factorial and Fractional Factorial arrangements of treatments and Response Surface methods are covered. Integrated throughout the book are rich sets of examples and problems that help readers gain a better understanding of where and how to apply statistical quality control tools. These large and realistic problem sets in combination with the...

  10. Terms and definitions of quality assurance/quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1980-01-01

    Terms of quality assurance are defined and interpreted. Reference is made to the IAEA Code of Practice and to other important Codes and Standards like ANSI, ASME and KTA. The relevance of these terms to everyday's work and problems of a quality assurance engineer is explained. (orig.)

  11. Reinforcing Quality Assurance in Romanian Higher Education

    Directory of Open Access Journals (Sweden)

    Ana-Maria Dima

    2010-07-01

    Full Text Available Since 1993, the quality assurance system in Romania has gained considerable experience. This experience was recently recognized in 2008 by the ENQA: European Association for Quality Assurance in Higher Education through the admission of ARACIS as a full member of EQAR: the European Quality Assurance Register. The Board of ENQA agreed to grant ARACIS’s full membership of ENQA for five years from 2 June 2009. This article explores the benefits of membership for the Romanian Agency for Quality Assurance in Higher Education – ARACIS, comparing to other regional and global quality assurance agencies networks. The common features and differences between ARACIS and other European agencies are questioned through the frameworks of ENQA and INQAAHE as a case study.

  12. Quality assurance in the manufacture of pressure components

    International Nuclear Information System (INIS)

    Knoedler, D.

    1979-01-01

    New regulations for nuclear power plants emphasize more quality assurance than it was the case in the past. Quality assurance is a management tool. During erection the quality assurance measures of the manufacturer, the main contractor and the required quality and the reliability of the proof of quality. The qualification of processes, equipment and personnel is a significant measure of quality assurance. The proof for quality assurance to be effective needs not only system-oriented audits, but also product audits aimed at quality characteristics of the product itself. The existing problems of examination techniques not optimized according to latest experience and of the large volume of documetation will persist in case the existing regulations are not adjusted according to the results of relevant studies. Furthermore the effectiveness of quality assurance is too often hampered by vague definitions of the safety objectives. (orig.) [de

  13. Labelled agents for PET studies of the dopaminergic system -some quality assurance methods, experience and issues

    International Nuclear Information System (INIS)

    Pike, V.W.; Kensett, M.J.; Turton, D.R.; Waters, S.L.; Silvester, D.J.

    1990-01-01

    Practical methods are described for the quality assurance of three labelled agents (L-6-[ 18 F]fluoro-DOPA, S-[N-methyl- 11 C]nomifensine and [O-methyl- 11 C]raclopride) now produced regularly for PET studies of the dopaminergic system in man. These include indirect methods for the initial determination of label position (e.g. 13 C-NMR spectroscopy) and also direct methods for the assessment of chiral purity (TLC and HPLC) and the routine determination of radiochemical purity, chemical purity and specific activity (HPLC). Mass spectrometry has been used to identify some impurities. L-6-hydroxy-DOPA (a precursor in vivo of the neurotoxin, L-6-hydroxydopamine) has been detected by HPLC in some preparations of L-6-[ 18 F]fluoro-DOPA. Formulated S-[N-methyl- 11 C]nomifensine has been found to be stable. Some quality assurance issues are discussed in relation to experience in the application of the described methods and the obtained results. (author)

  14. 21 CFR 58.35 - Quality assurance unit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Quality assurance unit. 58.35 Section 58.35 Food... LABORATORY PRACTICE FOR NONCLINICAL LABORATORY STUDIES Organization and Personnel § 58.35 Quality assurance unit. (a) A testing facility shall have a quality assurance unit which shall be responsible for...

  15. Quality assurance for the safe transport of radioactive material

    International Nuclear Information System (INIS)

    1994-01-01

    All activities related to the safe transport of radioactive material should be covered by a quality assurance programme. This publication recognizes that a single transport operation often involves several different organizations, each having specific responsibilities. Hence, it is unlikely that the operation will be covered by a single quality assurance programme. Each quality assurance programme should be tailored to the specific organizational structure for which the programme is prepared, with account taken of the particular transport activities of that organization and the interfaces with other organizations. The aim of this publication is to give a detailed interpretation of what must be done by whom to produce a quality assurance programme for radioactive material transport. This publication provides guidance on methods and practical examples to develop QA programmes for the safe transport of radioactive material. It provides information on how to develop the programme, the standards and the common features of a QA programme

  16. Quality assurance and quality control

    International Nuclear Information System (INIS)

    Kaden, W.

    1986-01-01

    General preconditions and methods for QA work in the nuclear field are analysed. The application of general QA principles to actual situations is illustrated by examples in the fields of engineering and of the manufacturing of mechanical and electrical components. All QA measures must be fitted to the complexity and relevance of the work steps, which are under consideration. The key to good product quality is the control of working processes. The term 'controlled process' is discussed in detail and examples of feed back systems are given. The main QA measures for the operation of nuclear power plants include the establishment of a Quality Assurance Program, training and qualification of personnel, procurement control, inspection and tests, reviews and audits. These activities are discussed. (orig.)

  17. Quantitative research versus quality assurance, quality improvement, total quality management, and continuous quality improvement.

    Science.gov (United States)

    Vogelsang, J

    1999-04-01

    The purpose of this report is to provide a review of the scientific method used in the quantitative research studies for consumers, evaluators, and applied nurse researchers. The fundamental characteristics of the problem-solving/ performance-improvement processes of quality assurance, quality improvement, total quality management, and continuous quality improvement are described. Research is compared with these processes, and is followed by a discussion about the publication of quantitative research findings.

  18. Recent Trends in Quality Assurance

    Science.gov (United States)

    Amaral, Alberto; Rosa, Maria Joao

    2010-01-01

    In this paper we present a brief description of the evolution of quality assurance in Europe, paying particular attention to its relationship to the rising loss of trust in higher education institutions. We finalise by analysing the role of the European Commission in the setting up of new quality assurance mechanisms that tend to promote…

  19. Designing and implementing a trust-wide quality assurance programme.

    Science.gov (United States)

    Coope, Sally-Ann

    2018-04-02

    Derbyshire Community Health Services (DCHS) NHS Foundation Trust provides a wide range of community-based health services. After the Care Quality Commission (CQC) found gaps in the trust's assurance process, its board decided to develop a method of continuous quality improvements that could be used as a basis for the trust's quality assurance system. The trust adapted and built on an acute model so it was suitable for community services. The final assurance system, Quality Always, has four elements: the clinical assessment and accreditation scheme; leadership development; 'champions' within clinical teams to support and promote the scheme; and dashboards to record and monitor progress. A system to recognise and reward achievement was essential for success. Quality Always has resulted in better care quality, an improved CQC rating, a sense of achievement among staff, the development of support networks, learning (especially among support staff) and good practice being shared.

  20. Has quality assurance outlived its usefulness

    International Nuclear Information System (INIS)

    Goldenberg, N.

    1989-01-01

    This paper explores the impact that better management and increased productivity will have on the need for, and role of, quality assurance in the future. The author discusses criticisms of existing quality assurance programs

  1. Opinion of gastroenterologists towards quality assurance in endoscopy.

    Science.gov (United States)

    de Jonge, Vincent; Kuipers, Ernst J; van Leerdam, Monique E

    2011-03-01

    Quality assurance has become an important issue. Many societies are adopting quality assurance programs in order to monitor and improve quality of care. To assess the opinion of gastroenterologists towards quality assurance on the endoscopy department. A survey was sent to all gastroenterologists (n=319) in the Netherlands. It assessed their opinion on a quality assurance program for endoscopy units, including its design, logistics, and content. 200 gastroenterologists (63%) completed the questionnaire. 95% had a positive opinion towards quality assurance and 67% supposed an increase in quality. 28% assumed a negative impact on the time available for patient contact by introducing a quality assurance program and 35% that the capacity would decrease. A negative attitude towards disclosure of results to insurance companies (23%) and media (53%) was reported. Female gastroenterologists were less positive to share the results with other stakeholders (pquality measurements were assessment of complications (97%), standardised reporting (96%), and adequate patient information (95%). Gastroenterologists have a positive attitude towards quality assurance. However, concerns do exist about time investment and disclosure of results to others. Information provision and procedure characteristics were considered the most important aspects of quality assurance. Copyright © 2010 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.

  2. Examination of fast reactor fuels, FBR analytical quality assurance standards and methods, and analytical methods development: irradiation tests. Progress report, April 1--June 30, 1976, and FY 1976

    International Nuclear Information System (INIS)

    Baker, R.D.

    1976-08-01

    Characterization of unirradiated and irradiated LMFBR fuels by analytical chemistry methods will continue, and additional methods will be modified and mechanized for hot cell application. Macro- and microexaminations will be made on fuel and cladding using the shielded electron microprobe, emission spectrograph, radiochemistry, gamma scanner, mass spectrometers, and other analytical facilities. New capabilities will be developed in gamma scanning, analyses to assess spatial distributions of fuel and fission products, mass spectrometric measurements of burnup and fission gas constituents and other chemical analyses. Microstructural analyses of unirradiated and irradiated materials will continue using optical and electron microscopy and autoradiographic and x-ray techniques. Analytical quality assurance standards tasks are designed to assure the quality of the chemical characterizations necessary to evaluate reactor components relative to specifications. Tasks include: (1) the preparation and distribution of calibration materials and quality control samples for use in quality assurance surveillance programs, (2) the development of and the guidance in the use of quality assurance programs for sampling and analysis, (3) the development of improved methods of analysis, and (4) the preparation of continuously updated analytical method manuals. Reliable analytical methods development for the measurement of burnup, oxygen-to-metal (O/M) ratio, and various gases in irradiated fuels is described

  3. Quality assurance for image-guided radiotherapy

    International Nuclear Information System (INIS)

    Marinello, Ginette

    2008-01-01

    The topics discussed include, among others, the following: Quality assurance program; Image guided radiotherapy; Commissioning and quality assurance; Check of agreement between visual and displayed scales; quality controls: electronic portal imaging device (EPID), MV-kV and kV-kV, cone-beam CT (CBCT), patient doses. (P.A.)

  4. SWiFT Software Quality Assurance Plan.

    Energy Technology Data Exchange (ETDEWEB)

    Berg, Jonathan Charles [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2016-01-01

    This document describes the software development practice areas and processes which contribute to the ability of SWiFT software developers to provide quality software. These processes are designed to satisfy the requirements set forth by the Sandia Software Quality Assurance Program (SSQAP). APPROVALS SWiFT Software Quality Assurance Plan (SAND2016-0765) approved by: Department Manager SWiFT Site Lead Dave Minster (6121) Date Jonathan White (6121) Date SWiFT Controls Engineer Jonathan Berg (6121) Date CHANGE HISTORY Issue Date Originator(s) Description A 2016/01/27 Jon Berg (06121) Initial release of the SWiFT Software Quality Assurance Plan

  5. Quality assurance of operating instructions

    International Nuclear Information System (INIS)

    Asmuss, G.

    1992-01-01

    It is pointed out that the quality assurance at nuclear power stations must be supported by national and international regulations. Quality assurance is explained using the example of the design of a pressurised water reactor. The operating and emergency manuals are discussed and examples for their structure put forward. The significance of updating is emphasised. 15 figs., 19 refs

  6. Quality assurance of qualitative research: a review of the discourse

    Directory of Open Access Journals (Sweden)

    Reynolds Joanna

    2011-12-01

    Full Text Available Abstract Background Increasing demand for qualitative research within global health has emerged alongside increasing demand for demonstration of quality of research, in line with the evidence-based model of medicine. In quantitative health sciences research, in particular clinical trials, there exist clear and widely-recognised guidelines for conducting quality assurance of research. However, no comparable guidelines exist for qualitative research and although there are long-standing debates on what constitutes 'quality' in qualitative research, the concept of 'quality assurance' has not been explored widely. In acknowledgement of this gap, we sought to review discourses around quality assurance of qualitative research, as a first step towards developing guidance. Methods A range of databases, journals and grey literature sources were searched, and papers were included if they explicitly addressed quality assurance within a qualitative paradigm. A meta-narrative approach was used to review and synthesise the literature. Results Among the 37 papers included in the review, two dominant narratives were interpreted from the literature, reflecting contrasting approaches to quality assurance. The first focuses on demonstrating quality within research outputs; the second focuses on principles for quality practice throughout the research process. The second narrative appears to offer an approach to quality assurance that befits the values of qualitative research, emphasising the need to consider quality throughout the research process. Conclusions The paper identifies the strengths of the approaches represented in each narrative and recommend these are brought together in the development of a flexible framework to help qualitative researchers to define, apply and demonstrate principles of quality in their research.

  7. Quality assurance of qualitative research: a review of the discourse

    Science.gov (United States)

    2011-01-01

    Background Increasing demand for qualitative research within global health has emerged alongside increasing demand for demonstration of quality of research, in line with the evidence-based model of medicine. In quantitative health sciences research, in particular clinical trials, there exist clear and widely-recognised guidelines for conducting quality assurance of research. However, no comparable guidelines exist for qualitative research and although there are long-standing debates on what constitutes 'quality' in qualitative research, the concept of 'quality assurance' has not been explored widely. In acknowledgement of this gap, we sought to review discourses around quality assurance of qualitative research, as a first step towards developing guidance. Methods A range of databases, journals and grey literature sources were searched, and papers were included if they explicitly addressed quality assurance within a qualitative paradigm. A meta-narrative approach was used to review and synthesise the literature. Results Among the 37 papers included in the review, two dominant narratives were interpreted from the literature, reflecting contrasting approaches to quality assurance. The first focuses on demonstrating quality within research outputs; the second focuses on principles for quality practice throughout the research process. The second narrative appears to offer an approach to quality assurance that befits the values of qualitative research, emphasising the need to consider quality throughout the research process. Conclusions The paper identifies the strengths of the approaches represented in each narrative and recommend these are brought together in the development of a flexible framework to help qualitative researchers to define, apply and demonstrate principles of quality in their research. PMID:22182674

  8. QAM: PROPOSED MODEL FOR QUALITY ASSURANCE IN CBSS

    Directory of Open Access Journals (Sweden)

    Latika Kharb

    2015-08-01

    Full Text Available Component-based software engineering (CBSE / Component-Based Development (CBD lays emphasis on decomposition of the engineered systems into functional or logical components with well-defined interfaces used for communication across the components. Component-based software development approach is based on the idea to develop software systems by selecting appropriate off-the-shelf components and then to assemble them with a well-defined software architecture. Because the new software development paradigm is much different from the traditional approach, quality assurance for component-based software development is a new topic in the software engineering research community. Because component-based software systems are developed on an underlying process different from that of the traditional software, their quality assurance model should address both the process of components and the process of the overall system. Quality assurance for component-based software systems during the life cycle is used to analyze the components for achievement of high quality component-based software systems. Although some Quality assurance techniques and component based approach to software engineering have been studied, there is still no clear and well-defined standard or guidelines for component-based software systems. Therefore, identification of the quality assurance characteristics, quality assurance models, quality assurance tools and quality assurance metrics, are under urgent need. As a major contribution in this paper, I have proposed QAM: Quality Assurance Model for component-based software development, which covers component requirement analysis, component development, component certification, component architecture design, integration, testing, and maintenance.

  9. Software Quality Assurance activities of ITER CODAC

    Energy Technology Data Exchange (ETDEWEB)

    Pande, Sopan, E-mail: sopan.pande@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France); DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders [ITER Organization, Route de Vinon sur Verdon, 13115 St Paul Lez Durance (France)

    2013-10-15

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements.

  10. Software Quality Assurance activities of ITER CODAC

    International Nuclear Information System (INIS)

    Pande, Sopan; DiMaio, Franck; Kim, Changseung; Kim, Joohan; Klotz, Wolf-Dieter; Makijarvi, Petri; Stepanov, Denis; Wallander, Anders

    2013-01-01

    Highlights: ► Comprehensive and consistent software engineering and quality assurance of CODAC. ► Applicable to all CODAC software projects executed by ITER DAs and contractors. ► Configurable plans for cost effective application of SQA processes. ► CODAC software plans SQAP, SVVP, SDP, and SCMP. ► CODAC software processes based on IEEE 12207-2008. -- Abstract: Software as an integral part of the plant system I and C is crucial in the manufacturing and integrated operation of ITER plant systems. Software Quality Assurance is necessary to ensure the development and maintenance of consistently high quality I and C software throughout the lifetime of ITER. CODAC decided to follow IEEE 12207-2008 software lifecycle processes for Software Engineering and Software Quality Assurance. Software Development Plan, Software Configuration Management Plan and Software Verification and Validation Plan are the mainstay of Software Quality Assurance which is documented in the Software Quality Assurance Plan. This paper describes the Software Quality Assurance (SQA) activities performed by CODAC. The SQA includes development and maintenance of above plans, processes and resources. With the help of Verification and Validation Teams they gather evidence of process conformance and product conformance, and record process data for quality audits and perform process improvements

  11. Quality assurance - not only for engineers

    International Nuclear Information System (INIS)

    Treffner, F.W.

    1984-01-01

    The actual purpose of quality assurance is the definition of effective processes, ways and means of planning, fabricating and obtaining the required characteristics determining the quality of components, subsystems and their fabrication techniques at any place and any time. Service companies can contribute quality assurance, quality control and documentation work do cost-benefit analyses and act as expert consultants. (orig.) [de

  12. Statistical methods in quality assurance

    International Nuclear Information System (INIS)

    Eckhard, W.

    1980-01-01

    During the different phases of a production process - planning, development and design, manufacturing, assembling, etc. - most of the decision rests on a base of statistics, the collection, analysis and interpretation of data. Statistical methods can be thought of as a kit of tools to help to solve problems in the quality functions of the quality loop with respect to produce quality products and to reduce quality costs. Various statistical methods are represented, typical examples for their practical application are demonstrated. (RW)

  13. Quality assurance in ionizing radiation application

    International Nuclear Information System (INIS)

    Rastkhah; Nasser.

    1995-01-01

    Quality assurance is a mean for controlling all the activities within an organization which affect the quality of the product or service. A series of international standards have been prepared which incorporate the accumulated knowledge and provide guidance on what activities within an organization should be controlled. A proposal on a quality assurance system to be implemented in ionizing radiation application centers is the primary concern of Atomic Energy Organization of Iran is represented. The Objectives were identification of quality related problems ;Comply with national and international requirements ;Controlling all activities within an organization which affects the quality and assurance of maintaining the quality within organization. In performing protection measures, risk, cost, benefit consideration, cause of problems and the classic solution are summarized in four chapters

  14. [Quality assurance in colorectal cancer in Europe AD 2011].

    Science.gov (United States)

    Mroczkowski, P; Hac, S; Lippert, H; Kube, R

    2013-12-01

    Malignant tumours are the second largest cause of death in Europe. Colorectal cancer takes second place within this group and is responsible for every eighth tumour-related death. Surgical quality assurance requires a prospective observational study, any different type of study is not possible. A complete recording of all treated patients is a prerequisite for quality assurance. Currently, there are quality assurance programmes in Sweden, Norway, Denmark, Great Britain, Spain, Belgium, the Netherlands as well as the multinational study for patients from Germany, Poland and Italy. These projects deliver comprehensive information regarding the treatment of colorectal cancer. However, this information is deeply rooted in the organisation of the health-care system in the given country and is not easily transferable into international settings. Also, an interpretation of the collected data is often possible only within the given health-care system. First, unified initial diagnostics is a prerequisite for quality assurance -  for the local extent and exclusion / confirmation of distant metastases. Until these criteria are unified, any comparison is limited, including a comparison of survival. Second, quality-of-life is not recorded in any of the current projects. Third, the main focus of a quality assurance project must be on therapy-dependent factors. The most sensible method of quality control remains within the connection of preoperative diagnostics (estimate of a best-case scenario), the surgical technique (the actual result) and a standardised pathological examination (evaluation of the actual result). These parameters can be recorded and compared within a quality assurance project regardless of the limitations of the national health-care systems. There is no alternative to a unified diagnostics model and unified histopathological evaluation, a complete picture of treatment quality is also not possible without systematic analysis of the quality of life.

  15. Quality Assurance--Best Practices for Assessing Online Programs

    Science.gov (United States)

    Wang, Qi

    2006-01-01

    Educators have long sought to define quality in education. With the proliferation of distance education and online learning powered by the Internet, the tasks required to assess the quality of online programs become even more challenging. To assist educators and institutions in search of quality assurance methods to continuously improve their…

  16. 48 CFR 2453.246 - Quality Assurance.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Quality Assurance. 2453.246 Section 2453.246 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND URBAN DEVELOPMENT CLAUSES AND FORMS FORMS Prescription of Forms 2453.246 Quality Assurance. ...

  17. Quality assurance manual: Volume 2, Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department. (LSP)

  18. Quality assurance manual: Volume 2, Appendices

    International Nuclear Information System (INIS)

    Oijala, J.E.

    1988-06-01

    This paper contains quality assurance information on departments of the Stanford Linear Accelerator Center. Particular quality assurance policies and standards discussed are on: Mechanical Systems; Klystron and Microwave Department; Electronics Department; Plant Engineering; Accelerator Department; Purchasing; and Experimental Facilities Department

  19. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-02-01

    The Topical Report presented establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of the report

  20. Quality assurance program for nuclear power plants

    International Nuclear Information System (INIS)

    Gamon, T.H.

    1976-06-01

    This topical report establishes and provides the basis for the Brown and Root Quality Assurance Program for Nuclear Power Plants from which the Brown and Root Quality Assurance Manual is prepared and implemented. The Quality Assurance Program is implemented by the Brown and Root Power Division during the design, procurement, and construction phases of nuclear power plants. The Brown and Root Quality Assurance Program conforms to the requirements of Nuclear Regulatory Commission Regulation 10 CFR 50, Appendix B; to approved industry standards such as ANSI N45.2 and ''Daughter Standards''; or to equivalent alternatives as indicated in the appropriate sections of this report

  1. High dose-rate brachytherapy source position quality assurance using radiochromic film

    International Nuclear Information System (INIS)

    Evans, M.D.C.; Devic, S.; Podgorsak, E.B.

    2007-01-01

    Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance

  2. Qualification of quality assurance program audit personnel for nuclear power plants - August 1980

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Appendix B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants, to 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, establishes overall quality assurance requirements for the design, construction, and operation of safety-related structures, and components of nuclear power plants. Criterion XVIII, Audits, of Appendix B establishes requirements for conducting audits of the quality assurance program. This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to qualification of quality assurance program audit personnel for nuclear power plants

  3. Quality Assurance in Chinese Higher Education

    Science.gov (United States)

    Li, Yuan

    2010-01-01

    Quality assurance has been integrated into the fabric of higher education in China, with the issue of quality in higher education--how to evaluate it and how to enhance it--now taking centre stage in Chinese higher education. In the past decade, the development of quality assurance in Chinese higher education has covered a broad spectrum of…

  4. Hungary Higher Education Quality Assurance System

    Directory of Open Access Journals (Sweden)

    Che Ru-shan

    2013-07-01

    Full Text Available Higher education quality assurance system has drawn much attention since 1980s. Most countries are committed to build the higher education quality assurance system to meet international standards. Under such an international trend, Hungary also actively promotes higher education reform, and established Hungarian Accreditation Committee and in order to ensure the quality of higher education.

  5. Quality assurance for safety in the radioactive waste management: a quality assurance system in Novi Han radioactive waste repository

    International Nuclear Information System (INIS)

    Petrova, A.; Kolev, I.

    2000-01-01

    Novi Han Radioactive Waste Repository (RWR) is still the only place in Bulgaria for storage of low and intermediate level radioactive waste. It is necessary to establish and maintain a Quality Assurance (QA) system to ensure that the RWR can be operated safely with regard to the health and safety of the general public and site personnel. A QA system has to establish the basic requirements for quality assurance in order to enhance nuclear safety by continuously improving the methods employed to achieve quality. It is envisaged that the QA system for the Novi Han RWR will cover the operation and maintenance of the radioactive waste disposal facilities, the radiation protection and monitoring of the site, as well as the scientific and technology development aspects. The functions of the Novi Han RWR presume the availability of an environmental management system. It is appropriate to establish a QA system based on the requirements of the ISO Standards 9001 and 14000, using the recommendations of the IAEA (Quality assurance for safety in NPPs and other nuclear installations, code and safety guides Q1-Q14). (authors)

  6. Application of Quality Assurance Mechanisms for Effective Library ...

    African Journals Online (AJOL)

    The main strategy used for implementation of quality assurance was integration of the library` services quality assurance agenda into the university structures and the quality assurance mechanisms available and used in Nigerian university libraries were programme accreditation and benchmarking of library systems.

  7. Field Methods and Quality-Assurance Plan for Quality-of-Water Activities, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Knobel, LeRoy L.; Tucker, Betty J.; Rousseau, Joseph P.

    2008-01-01

    Water-quality activities conducted by the staff of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation's water resources. The activities are conducted in cooperation with the U.S. Department of Energy's (DOE) Idaho Operations Office. Results of the water-quality investigations are presented in various USGS publications or in refereed scientific journals. The results of the studies are highly regarded, and they are used with confidence by researchers, regulatory and managerial agencies, and interested civic groups. In its broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the 'state-of-the-art' technology, and quality assurance ensures that quality control is maintained within specified limits.

  8. Quality assurance and the sub-contract interface: co-operative evaluations

    International Nuclear Information System (INIS)

    Churchill, G.F.; Rippon, D.J.

    1976-01-01

    A common feature of all contemporary Quality Assurance Standards is the requirement for organisations, when carrying out purchasing activities, to select their suppliers on the basis of either a proven record or demonstrated quality capability. In particular the C.E.G.B. Standard QA42-1 Quality Assurance Programme, which the C.E.G.B. will apply to their future major projects, requires purchasers to establish supplier selection and assessment procedures using one or other of the following methods: (a) a previous continuous record of supplying identical or equivalent material to a satisfactory standard; or (b) an evaluation of the sub-contractor's quality assurance system to determine his ability to satisfy the procurement requirements. Co-operative evaluations, where there are several suppliers, are discussed. (author)

  9. Quality assurance in radiotherapy

    International Nuclear Information System (INIS)

    2003-03-01

    Good radiotherapy results and safety of treatment require the radiation to be optimally applied to a specified target area and the correct dose. According to international recommendations, the average uncertainty in therapeutic dose should not exceed 5%. The need for high precision in therapeutic dose requires quality assurance covering the entire radiotherapy process. Besides the physical and technical characteristics of the therapy equipment, quality assurance must include all radiotherapy equipment and procedures that are significant for the correct magnitude and precision of application of the therapeutic dose. The duties and responsibilities pertaining to various stages of treatment must also be precisely defined. These requirements may be best implemented through a quality system. The general requirements for supervision and quality assurance of medical radiation apparatus are prescribed in section 40 of the Radiation Act (592/1991, amendment 1142/1998) and in sections 18 and 32 of the Decree of the Ministry of Social Affairs and Health on the medical use of radiation (423/2000). Guide ST 2.2 imposes requirements on structural radiation shielding of radiotherapy equipment and the premises in which it is used, and on warning and safety arrangements. Guide ST 1.1 sets out the general safety principles for radiation practices and regulatory control procedure for the use of radiation. Guide ST 1.6 provides general requirements for operational measures in the use of radiation. This Guide sets out the duties of responsible parties (the party running a radiation practice) in respect of arranging and maintaining radiotherapy quality assurance. The principles set out in this Guide and Guide ST 6.3 may be applied to radionuclide therapy

  10. Monitoring of performance management using Quality Assurance Indicators and ISO requirement

    Directory of Open Access Journals (Sweden)

    Dargahi H

    2007-06-01

    Full Text Available Background: Quality assurance is a prevention-oriented system that can be used to improve the quality of care, increase productivity and monitor the performance management in clinical laboratories. ISO 9001: 2000 requirements are a collection of management and technical systems designed to implement quality assurance and monitor performance management in organizations. Methods: A checklist was prepared to monitor the preanalytical, analytical and postanalytical stages of laboratory performance management in 16 areas and all laboratory activities in 14 of the clinical laboratories of the Tehran University of Medical Sciences (TUMS hospitals. Collected data were stored and statistically analyzed using SPSS software. Results: The best performance, in which 77.73% of quality assurance indicators were observed, was found in Sina Hospital. However, only 57.56% of these indicators were fulfilled at Farabi Hospital, with the lowest-level performance among the clinical laboratories of TUMS hospitals. The highest level of compliance with quality assurance indicators was in the hematology departments and for facility demands in management areas. Overall, quality assurance indicators were appropriately followed in only 7% of the clinical laboratories. Conclusion: The average quality assurance observation rate in the clinical laboratories studied was 67.22%, which is insufficient and must be remedied with stricter enforcement of the ISO 9001: 2000 regulations.

  11. Problems of quality assurance and quality control in diagnostic radiology

    International Nuclear Information System (INIS)

    Angerstein, W.

    1986-01-01

    Topical problems of quality assurance and quality control in diagnostic radiology are discussed and possible solutions are shown. Complex units are differentiated with reference to physicians, technicians, organization of labour, methods of examination and indication. Quality control of radiologic imaging systems should involve three stages: (1) simple tests carried out by radiologic technicians, (2) measurements by service technicians, (3) testing of products by the manufacturer and independent governmental or health service test agencies. (author)

  12. Quality assurance and demolition: 2006 symposium

    International Nuclear Information System (INIS)

    Thierfeldt, S.

    2006-01-01

    The '2006 Symposium: Quality Assurance and Demolition' jointly organized by compra GmbH and Brenk Systemplanung GmbH this year again focused on quality assurance and the demolition of nuclear facilities as its main topics. The papers presented ranged from issues of clearance and disposal to demolition technologies and status reports about specific demolition projects. The sixteen presentations at the '2006 Symposium: Quality Assurance and Demolition' offered an interesting and very topical cross section of decommissioning and demolition of nuclear facilities in Germany. In 2007, the conference about similar main topics will again be held at the Schloss Bensberg Grand Hotel. (orig.)

  13. Quality assurance for health and environmental chemistry: 1986

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Moss, W.D.; Phillips, M.B.; O'Malley, B.T.

    1987-11-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group at the Los Alamos National Laboratory. The philosophy, methodology, and computing resources used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1986. 27 refs., 3 figs

  14. National Program of Quality Assurance in Radiotherapy in Cuba

    International Nuclear Information System (INIS)

    Alonso Samper, J. L.; Dominguez Hung, L.; Morales Lopez, J. L.; Alfonso Laguardia, R.; Garcia Yip, F.

    2001-01-01

    It tries on the establishment of a Quality Assurance Nacional System, a Quality Assurance Committee implemented in Cuba, and a Quality Auditory National Program implemented in Cuba to control and assure radiotherapy quality

  15. Quality assurance, quality control and quality audit in diagnostic radiology

    International Nuclear Information System (INIS)

    Vassileva, J.

    2009-01-01

    Full text:The lecture aims to present contemporary view of quality assurance in X-Ray diagnosis and its practical realization in Bulgaria. In the lecture the concepts of quality assurance, quality control and clinical audit will be defined and their scope will be considered. An answer of the following questions will be given: why is it necessary to determine the dose of patient in X-ray studies, what is the reference dose level and how it is used for dosimetric quantity which characterized the patient's exposure in X-ray, mammography and CT scans and how they are measured, who conducted the measurement and how to keep the records, what are the variations of doses in identical tests and what defines them? The findings from a national survey of doses in diagnostic radiology, conducted in 2008-2009 and the developed new national reference levels will be presented. The main findings of the first tests of radiological equipment and the future role of quality control as well as the concept of conducting clinical audit and its role in quality assurance are also presented. Quality assurance of the diagnostic process with minimal exposure of patients is a strategic goal whose realization requires understanding, organization and practical action, both nationally and in every hospital. To achieve this the important role of education and training of physicians, radiological technicians and medical physicists is enhanced

  16. Quality assurance - how to involve the employees

    DEFF Research Database (Denmark)

    Jørgensen, Michael Søgaard

    1996-01-01

    An overview of strategies for involvement of employees in quality assurance developement and implementation.......An overview of strategies for involvement of employees in quality assurance developement and implementation....

  17. Quality assurance and nuclear power plant safety

    International Nuclear Information System (INIS)

    Mullan, J.V.

    1983-01-01

    Quality assurance in the nuclear industry was born in the late 1960s. Atomic Energy Control Board staff began its regulatory practice on quality assurance during that period. In this presentation the author traces the circumstances that first led to the establishment of Canadian nuclear power plant quality assurance programmes, summarizes progress over the last decade and a half, and outlines the current regulatory approach and what has been learned so far

  18. Annual Quality Assurance Conference Files by Tom Mancuso

    Science.gov (United States)

    25th Annual Quality Assurance Conference. Abstract: Learn about the NEW EPA Method 325b for Refinery Fence Line Monitoring and TO-17 Extended for Soil Gas by Tom Mancuso and Abstract: Success Using Alternate Carrier Gases for Volatile Methods

  19. Review of SKB's Quality Assurance Programme

    International Nuclear Information System (INIS)

    Baldwin, Tamara D.; Hicks, Timothy W.

    2009-06-01

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried of with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. SSM has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This project includes reviews of the quality assurance (QA) procedures and instructions that have been prepared for the SR-Site assessment as well as reviews of QA implementation at the canister and buffer/backfill laboratories in Oskarshamn, Sweden. The purpose of this project is to assess SKB's quality assurance with the view of providing a good basis for subsequent quality reviews in the context of future licensing. This has been achieved by examination of a number of SKB experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. Overall, the reviewed set of QA documents and instructions do provide reasonably comprehensive coverage of quality-affecting issues relating to the SR-Site safety assessment and, if implemented correctly, will generate confidence in the reliability of the safety assessment results. The results show that the efforts involving quality assurance are increasing within the SKB programme and in general appear to be satisfactory for ongoing experiments and measurements. However, progress in development of the QA documents and instructions has been relatively recent and it may be difficult for these to be fully implemented in the short period remaining before the planned licence

  20. Quality assurance of qualitative analysis

    DEFF Research Database (Denmark)

    Ríos, Ángel; Barceló, Damiá; Buydens, Lutgarde

    2003-01-01

    The European Commission has supported the G6MA-CT-2000-01012 project on "Metrology of Qualitative Chemical Analysis" (MEQUALAN), which was developed during 2000-2002. The final result is a document produced by a group of scientists with expertise in different areas of chemical analysis, metrology...... and quality assurance. One important part of this document deals, therefore, with aspects involved in analytical quality assurance of qualitative analysis. This article shows the main conclusions reported in the document referring to the implementation of quality principles in qualitative analysis...

  1. 30 CFR 7.7 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 7.7 Section 7.7 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS TESTING BY APPLICANT OR THIRD PARTY General § 7.7 Quality assurance. Applicants granted...

  2. Implementation of quality assurance with respect to product quality and scheduling

    International Nuclear Information System (INIS)

    Schleimer, W.F.

    1986-04-01

    Quality assurance means the whole range of actions which are necessary to meet the client's requirements for the product and the test methods. Audits: The preconditions for fabrication must be fulfilled by approval of the manufacturer's quality assurance system, the staff's qualification, his procedures and his equipments. This is done by means of a system audit at KWU or an equivalent organisation. Specifications: For quality assurance the requirements for the components are fixed in specifications. There are material specifications, process/procedure specifications, components specifications. Approval of Component Design and Manufacture (Scheduling): The approval procedure of a structurally welded part is described as an example of the approval of component design and manufacture, thus representing one small piece of a mechanical equipment. In-Process Surveillance (Product Audit): At KWU the in-process surveillance is regulated by a KQ- or product audit concept. In this concept we have K- and KQ-steps. The list of KQ-steps will be presented. Documentation: All test or examination steps are documented with certificates, lists, and stamps for the final documentation. 19 figs

  3. Quality assurance for fittings considering nuclear technology

    International Nuclear Information System (INIS)

    Kilian, H.J.

    1987-01-01

    Negative experience made during World War II led to the idea of quality assurance being born in the United States. Thoroughly misunderstood, it came to be incorporated in European mechanical engineering. Quality assurance there was initially considered to be a new term for the oganizational combination of all parts of an enterprise dealing with testing. German manufacturers of heavy-duty and safety fittings represented in the international market were compelled at a relatively early date to properly understand and realize a quality assurance programme. But the multi-fariousness of specifications to be applied and great number of the most different parts made eminent demands on the suitability and variability of the products developed. On the basis of 18 quality criteria the article describes the structure of 'quality' and what its consequences are for an effective quality assurance system - suited for all kinds of specifications. (orig.) [de

  4. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  5. Quality Assurance: Strategic Choices for Higher Education in Turkey

    Directory of Open Access Journals (Sweden)

    Mahmut ÖZER

    2011-01-01

    Full Text Available As the number of students and higher education institutions in the world increases and there is a growing difficulty in financing the higher education systems, decision-makers have begun to show more interest in quality assurance. As quality assurance is given special attention in European countries, developing countries such as Turkey are interested in importing quality assurance systems. It is not possible to set quality assurance without sensitivity toward quality and without having quality as a cultural practice. The most likely encountered quality assurance approach in the world is that the higher education institution itself is responsible for its quality. In addition, external quality assurance procedures used are based on (academic peer review rather than on bureaucratic evaluations. Moreover, there is a lively debate across the world regarding the bureaucratic regulations of the quality assurance agencies and institutions that restrict the autonomy of higher education institutions. Without taking into consideration of the existing centralized structure of the higher education system in Turkey, of meeting social demands for the higher education, and of current higher education enrollment rates, the possible establishment of a quality assurance mechanism that may have sanctions on universities in Turkey is a threat to already limited autonomy of universities and is having a risk of additional bureaucratic burden. By laying out the roles and responsibilities of Turkish Council of Higher Education, the government and universities, this article discusses policies that should be adopted regarding the quality assurance.

  6. Quality assurance system in nuclear engineering

    International Nuclear Information System (INIS)

    Adams, H.W.; Hoensch, V.

    1985-01-01

    Due to the close connection between the German Atomic Energy Law and the nuclear control regulations, quality systems in nuclear engineering have taken on a special form. Quality assurance systems as a stipulated organisation of structure and procedure to assure quality have implications for the organisation of the electric supply company at the planning, erection and commissioning stage and for the organisation of the nuclear power station facility. To supervise the application and effectiveness of the stipulated organisation of structure and procedure internally and externally among contractors, special organisation units have been set up at the plant suppliers, manufactures, electric supply companies and nuclear power station facilities, which in the electric supply field go by the name of Quality Assurance Supervision. (orig.) [de

  7. Quality assurance for health and environmental chemistry: 1989

    International Nuclear Information System (INIS)

    Gautier, M.A.; Gladney, E.S.; Koski, N.L.; Jones, E.A.; Phillips, M.B.; O'Malley, B.T.

    1990-12-01

    This report documents the continuing quality assurance efforts of the Health and Environmental Chemistry Group (HSE-9) at the Los Alamos National Laboratory. The philosophy, methodology, computing resources, and laboratory information management system used by the quality assurance program to encompass the diversity of analytical chemistry practiced in the group are described. Included in the report are all quality assurance reference materials used, along with their certified or consensus concentrations, and all analytical chemistry quality assurance measurements made by HSE-9 during 1989. 38 refs., 8 figs., 3 tabs

  8. A Quality Assurance Program for decommissioning

    International Nuclear Information System (INIS)

    Briggs, P.M.

    1986-01-01

    Defining the Quality Assurance Program for the US Department of Energy Shippingport Station Decommissioning Project (SSDP) was a unique opportunity because this is the first full-sized commercial nuclear power plant to be decommissioned. General Electric Company defined a Quality Assurance Program that provided adequate control, yet was stripped down to the essentials. The Program is designed to provide a flexible degree of monitoring of subcontractor work, built around a core of radiation safety monitoring, detailed planning, inspection and auditing, and operated with a minimum of dedicated personnel. This paper will concentrate on the traditional quality assurance activities, leaving radiation and environmental monitoring for other presentations

  9. Assuring quality in high-consequence engineering

    Energy Technology Data Exchange (ETDEWEB)

    Hoover, Marcey L.; Kolb, Rachel R.

    2014-03-01

    In high-consequence engineering organizations, such as Sandia, quality assurance may be heavily dependent on staff competency. Competency-dependent quality assurance models are at risk when the environment changes, as it has with increasing attrition rates, budget and schedule cuts, and competing program priorities. Risks in Sandia's competency-dependent culture can be mitigated through changes to hiring, training, and customer engagement approaches to manage people, partners, and products. Sandia's technical quality engineering organization has been able to mitigate corporate-level risks by driving changes that benefit all departments, and in doing so has assured Sandia's commitment to excellence in high-consequence engineering and national service.

  10. 30 CFR 15.8 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Quality assurance. 15.8 Section 15.8 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF... § 15.8 Quality assurance. (a) Applicants granted an approval or an extension of approval under this...

  11. 40 CFR 194.22 - Quality assurance.

    Science.gov (United States)

    2010-07-01

    ... General Requirements § 194.22 Quality assurance. (a)(1) As soon as practicable after April 9, 1996, the Department shall adhere to a quality assurance program that implements the requirements of ASME NQA-1-1989... elicitation used to support applications for certification or re-certification of compliance; (vi) Design of...

  12. Quality Assurance in Sub-Saharan Africa

    Science.gov (United States)

    Materu, Peter; Righetti, Petra

    2010-01-01

    This article assesses the status and practice of higher education quality assurance in sub-Saharan Africa, focusing on degree-granting tertiary institutions. A main finding is that structured national-level quality assurance processes in African higher education are a very recent phenomenon and that most countries face major capacity constraints.…

  13. Current conceptions of industrial quality assurance

    International Nuclear Information System (INIS)

    Zeller, H.

    1978-01-01

    In the electrical engineering industry quality assurance is mainly oriented in accordance with the customers', users', and consumers' requirements concerning the quality of products (including reliability). These requirements are as manifold as the range of products itself. They do not only comprise functional criteria, but also safety against malfunctions, bodily injury or property damage. Quality assurance is embedded in the overall activities of a company; the peripheral conditions, such as organization, profitability, qualification, and responsibility of staff have to be considered. Thus, quality assurance in the electrical engineering industry proceeds in efficient systems which are adapted to the individual forms of production. These systems may include planning, testing, feedback of quality data, statistical procedures, costs and profitability. Their obvious interaction is based on the system of coordinates of integrated quality control. The paper will illustrate the basic features of this interaction by reference to various examples. (orig.) [de

  14. Quality assurance/quality control, reliability and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Kueffer, K.

    1981-01-01

    In a first part this lectures will present a survey on nuclear power production and plant performance in the Western World and discuss key parameters such as load factors and non-availability. Some main reasons for reliable performance of nuclear power plants are given. The second part of this lecture deals with the question how quality assurance and quality control measures do directly influence plant reliability, availability and, thus, economy. Derived from worldwide experience gained from operating nuclear power plants, it may be concluded that the implementation of an overall quality assurance programme does not only satisfy safety requirements set forth by the nuclear regulatory bodies, but has also a considerable impact on plant reliability and availability. A positive effect on these figures will be achieved if the established quality assurance programme provides for a coordinated approach to all activities affecting quality. It is discussed how the quality of a product should be controlled and what kind of quality assurance measures by performed examples are given to demonstrate that the expenditure for maintenance work on components will decrease if planned and systematic quality assurance actions have been implemented during all procurement stages. (orig./RW)

  15. Peer feedback for examiner quality assurance on MRCGP International South Asia: a mixed methods study.

    Science.gov (United States)

    Perera, D P; Andrades, Marie; Wass, Val

    2017-12-08

    The International Membership Examination (MRCGP[INT]) of the Royal College of General Practitioners UK is a unique collaboration between four South Asian countries with diverse cultures, epidemiology, clinical facilities and resources. In this setting good quality assurance is imperative to achieve acceptable standards of inter rater reliability. This study aims to explore the process of peer feedback for examiner quality assurance with regard to factors affecting the implementation and acceptance of the method. A sequential mixed methods approach was used based on focus group discussions with examiners (n = 12) and clinical examination convenors who acted as peer reviewers (n = 4). A questionnaire based on emerging themes and literature review was then completed by 20 examiners at the subsequent OSCE exam. Qualitative data were analysed using an iterative reflexive process. Quantitative data were integrated by interpretive analysis looking for convergence, complementarity or dissonance. The qualitative data helped understand the issues and informed the process of developing the questionnaire. The quantitative data allowed for further refining of issues, wider sampling of examiners and giving voice to different perspectives. Examiners stated specifically that peer feedback gave an opportunity for discussion, standardisation of judgments and improved discriminatory abilities. Interpersonal dynamics, hierarchy and perception of validity of feedback were major factors influencing acceptance of feedback. Examiners desired increased transparency, accountability and the opportunity for equal partnership within the process. The process was stressful for examiners and reviewers; however acceptance increased with increasing exposure to receiving feedback. The process could be refined to improve acceptability through scrupulous attention to training and selection of those giving feedback to improve the perceived validity of feedback and improved reviewer feedback

  16. Waste Management Quality Assurance Plan

    International Nuclear Information System (INIS)

    1993-01-01

    Lawrence Berkeley Laboratory's Environment Department addresses its responsibilities through activities in a variety of areas. The need for a comprehensive management control system for these activities has been identified by the Department of Energy (DOE). The WM QA (Waste Management Quality Assurance) Plan is an integral part of a management system that provides controls necessary to ensure that the department's activities are planned, performed, documented, and verified. This WM QA Plan defines the requirements of the WM QA program. These requirements are derived from DOE Order 5700.6C, Quality Assurance, the LBL Operating and Assurance Program Plan (OAP, LBL PUB-3111), and other environmental compliance documents applicable to WM activities. The requirements presented herein, as well as the procedures and methodologies that direct the implementation of these requirements, will undergo review and revisions as necessary. The provisions of this QA Plan and its implementing documents apply to quality-affecting activities performed by and for WM. It is also applicable to WM contractors, vendors, and other LBL organizations associated with WM activities, except where such contractors, vendors, or organizations are governed by their own WM-approved QA programs. References used in the preparation of this document are (1) ASME NQA-1-1989, (2) ANSI/ASQC E4 (Draft), (3) Waste Management Quality Assurance Implementing Management Plan (LBL PUB-5352, Rev. 1), (4) LBL Operating and Assurance Program Plan (OAP), LBL PUB-3111, 2/3/93. A list of terms and definitions used throughout this document is included as Appendix A

  17. Self–Evaluation of Distance Learning Study Program as a Part of Internal Quality Assurance

    Directory of Open Access Journals (Sweden)

    Radojka Krneta

    2012-02-01

    Full Text Available This paper features quality assurance of specific distance learning master study program through self-evaluation. This unique program involving e-learning as the program content, as well as delivery method, is presented in the paper from the aspects of its quality assurance. Student evaluation of this study program as a part of the internal quality assurance is performed at the end of every school year in the aim of its quality assurance. Results and conclusions of self-evaluation conducted in this school year by known SEVAQ+ evaluation tool are presented here.

  18. Nevada Nuclear Waste Storage Investigations: Quality Assurance Plan

    International Nuclear Information System (INIS)

    1980-08-01

    The Nevada Nuclear Waste Storage Investigations (NNWSI) were established by DOE/NV to evaluate the geohydrologic setting and underground rock masses of the Nevada Test Site (NTS) and contiguous areas to determine whether a suitable site exists for constructing a repository for isolating highly radioactive solid wastes. Since the results of these evaluations will impact possible risks to public health and safety, a quality assurance program which conforms to the criteria given in the Code of Federal Regulations is needed to control the quality aspects of the work. This Quality Assurance Plan (QAP) describes the general quality assurance program for the overall NNWSI project under which the quality assurance programs of the individual participating organizations and support contractors are to operate. The details of how each of these groups will meet the criteria will differ among participating organizations and support contractors, and those details are given in the QAPP's listed in Appendix A. It is the purpose of this plan to show the commonality of quality assurance programs in effect within the project and to define how each element fits into the entire picture to give total quality assurance coverage for the NNWSI Project

  19. R D software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Hood, F.C.

    1991-10-01

    Research software quality assurance (QA) requirements must be adequate to strengthen development or modification objectives, but flexible enough not to restrict creativity. Application guidelines are needed for the different kinds of research and development (R D) software activities to assure project objectives are achieved.

  20. Is quality assurance really necessary

    International Nuclear Information System (INIS)

    Elwen, L.

    1983-01-01

    The modern concept of quality assurance began to take root in the 50's in Japan. In the rest of the world the demand for quality of products and services might well have arisen through the demise of the craftsman, concurrent with a change in emphasis from quality and workmanship towards economy and output. In the beginning this metamorphosis had its virtues, when rationalisation of production methods benefited both producer and consumer. However, the increasing pressure on production in virtually all sectors of commerce and industry inevitably lead to a trend towards cutting corners, a philosophy not conducive to increasing the standards of quality. The shortage of skilled manpower began to make itself felt at about the same time. The civil construction industry did not remain unscathed

  1. Is quality assurance really necessary

    Energy Technology Data Exchange (ETDEWEB)

    Elwen, L

    1983-03-01

    The modern concept of quality assurance began to take root in the 50's in Japan. In the rest of the world the demand for quality of products and services might well have arisen through the demise of the craftsman, concurrent with a change in emphasis from quality and workmanship towards economy and output. In the beginning this metamorphosis had its virtues, when rationalisation of production methods benefited both producer and consumer. However, the increasing pressure on production in virtually all sectors of commerce and industry inevitably lead to a trend towards cutting corners, a philosophy not conducive to increasing the standards of quality. The shortage of skilled manpower began to make itself felt at about the same time. The civil construction industry did not remain unscathed.

  2. The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fix, N. J.

    2008-03-12

    Pacific Northwest National Laboratory researchers are working on the Columbia River Protection Supplemental Technologies Project. This project is a U. S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies, and technologies for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by the Technologies Project staff.

  3. Application of Quality Assurance to MCandA systems

    International Nuclear Information System (INIS)

    Skinner, A.J.; Delvin, W.L.

    1986-01-01

    Quality Assurance has been applied to the MCandA function within the Department of Energy's Savannah River Operations Office. It was applied to both the activities used to operate the MCandA Branch and the activities used by the Branch to overview the MCandA function of DOE/SR's contractor. In this paper, the principles of quality assurance are reviewed and their application at DOE/SR is discussed. In addition, quality assurance can be applied to the broader MCandA functions required of those facilities producing, using, and handling nuclear materials. Application of quality assurance to those broader functions is also discussed

  4. Quality assurance program plan fuel supply shutdown project

    International Nuclear Information System (INIS)

    Metcalf, I.L.

    1998-01-01

    This Quality Assurance Program plan (QAPP) describes how the Fuel Supply Shutdown (FSS) project organization implements the quality assurance requirements of HNF-MP-599, Project Hanford Quality Assurance Program Description (QAPD) and the B and W Hanford Company Quality Assurance Program Plan (QAPP), FSP-MP-004. The QAPP applies to facility structures, systems, and components and to activities (e.g., design, procurement, testing, operations, maintenance, etc.) that could affect structures, systems, and components. This QAPP also provides a roadmap of applicable Project Hanford Policies and Procedures (PHPP) which may be utilized by the FSS project organization to implement the requirements of this QAPP

  5. Quality assurance and statistical control

    DEFF Research Database (Denmark)

    Heydorn, K.

    1991-01-01

    In scientific research laboratories it is rarely possible to use quality assurance schemes, developed for large-scale analysis. Instead methods have been developed to control the quality of modest numbers of analytical results by relying on statistical control: Analysis of precision serves...... to detect analytical errors by comparing the a priori precision of the analytical results with the actual variability observed among replicates or duplicates. The method relies on the chi-square distribution to detect excess variability and is quite sensitive even for 5-10 results. Interference control...... serves to detect analytical bias by comparing results obtained by two different analytical methods, each relying on a different detection principle and therefore exhibiting different influence from matrix elements; only 5-10 sets of results are required to establish whether a regression line passes...

  6. Quality assurance systems at SKODA JS

    International Nuclear Information System (INIS)

    Janecek, P.

    2000-01-01

    In addition to technical requirements put upon the design, manufacture, installation and commissioning of equipment for nuclear power plants, emphasis is laid upon quality assurance of such activities so as to secure nuclear safety of installations over the world. As the technical level of nuclear safety assurance is being enhanced continuously, the requirements are becoming more and more stringent, which is mirrored by the relevant standards and legislation. SKODA JS has always been pursuing the quality goal and has been contributing to this aspect markedly. The quality assurance system at SKODA JS helps the company to satisfy all the appropriate requirements of its customers as well as the applicable standards and regulations. (author)

  7. Quality assurance organization of the plant owner

    International Nuclear Information System (INIS)

    Staebler, K.

    1980-01-01

    It is not the primary task of the plant owner to assure the quality during erection. It is, however, his responsibility to check the quality assurance system established by the plant, the supplier and the subcontractor. In the lecture, it is shown that the plant owners do this control in the best efficient way. The special consideration of the plant owner in deciding questions of quality assurance is demonstrated by special examples. The meaning of basic safety for the plant owner is presented. (orig./RW)

  8. Quality assurance in tube manufacture

    International Nuclear Information System (INIS)

    Depken, H.

    1976-01-01

    Reliability in service essential for many high-technology products fabricated today. This is particularly the case within the nuclear industry. Here defective materials or components may have diastrous consequences to the safety of human beings and the environment. A new concept - Quality Assurance - originates from this industry. The concept implies that all contractors, fabricators and material manufactures involved must prove that the quality control system used, fulfits particular requirements at all manufacturing, inspection and testing stages. These requirement are laid down in two standards issued by the U.S. Atomic Energy Commission and the American Society of Mechanical Engineers. These standards are discussed in the paper. As a manufacturer of steel products for nuclear applications Sandvik has been forced to establish a quality assurance system according to these principles. The Sandvik approach is briefly described with regard to organisation and other major quality assurance activities. Further the education and training of operators and technicians is touched upon. Finally some viewpoints regarding audits performed by customers of steel manufacturers are expressed. (author)

  9. [Quality assurance concepts in intensive care medicine].

    Science.gov (United States)

    Brinkmann, A; Braun, J P; Riessen, R; Dubb, R; Kaltwasser, A; Bingold, T M

    2015-11-01

    Intensive care medicine (ICM) is characterized by a high degree of complexity and requires intense communication and collaboration on interdisciplinary and multiprofessional levels. In order to achieve good quality of care in this environment and to prevent errors, a proactive quality and error management as well as a structured quality assurance system are essential. Since the early 1990s, German intensive care societies have developed concepts for quality management and assurance in ICM. In 2006, intensive care networks were founded in different states to support the implementation of evidence-based knowledge into clinical routine and to improve medical outcome, efficacy, and efficiency in ICM. Current instruments and concepts of quality assurance in German ICM include core intensive care data from the data registry DIVI REVERSI, quality indicators, peer review in intensive care, IQM peer review, and various certification processes. The first version of German ICM quality indicators was published in 2010 by an interdisciplinary and interprofessional expert commission. Key figures, indicators, and national benchmarks are intended to describe the quality of structures, processes, and outcomes in intensive care. Many of the quality assurance tools have proved to be useful in clinical practice, but nationwide implementation still can be improved.

  10. Commissioning quality assurance at Pickering NGS

    International Nuclear Information System (INIS)

    Wieckowski, J.T.

    1983-05-01

    Ontario Hydro decided in 1978 to implement a formal quality assurance program applicable to commissioning and operation of nuclear generating stations. Pickering NGS is the first station to have the commissioning quality assurance (CQA) program applied to it. This paper outlines the scope, implementation, and evaluation of the CQA program as applied to Pickering Unit 5

  11. Quality assurance program requirements (design and construction). Task RS 002-5. Revision 3

    International Nuclear Information System (INIS)

    1985-08-01

    This regulatory guide describes a method acceptable to the NRC staff for complying with regard to establishing and implementing the requisite quality assurance program for the design and construction of nuclear power plants. Guidance for the establishment and execution of quality assurance programs during operation and decommissioning of nuclear power plants have been or will be addressed in separate regulatory guides. Similarly, quality assurance provisions concerning fuel cycle facilities have been or will be addressed in separate regulatory guides

  12. Quality assurance requirements in various codes and standards

    International Nuclear Information System (INIS)

    Shaaban, H.I.; EL-Sayed, A.; Aly, A.E.

    1987-01-01

    The quality assurance requirements in various countries and according to various international codes and standards are presented, compared and critically discussed. Cases of developing countries are also discussed, and the use of IAEA code of practice and other codes for quality assurance in these countries is reviewed. Recommendations are made regarding the quality assurance system to be applied for Egypt's nuclear power plants

  13. Quality assurance applied to an environmental surveillance program

    International Nuclear Information System (INIS)

    Oakes, T.W.; Shank, K.E.; Eldridge, J.S.

    1977-01-01

    A discussion of a quality assurance program applied to environmental surveillance activities is presented. This includes the philosophy and concepts of quality assurance, along with a detailed assessment of the sources of uncertainty in a monitoring program. The role management must play for a successful program is also discussed, and the quality assurance program implemented at Oak Ridge National Laboratory is presented

  14. Quality Assurance in the European Higher Education Area: The Emergence of a German Market for Quality Assurance Agencies

    Science.gov (United States)

    Serrano-Velarde, Kathia E.

    2008-01-01

    Most European countries have introduced systematic quality assurance as part of an overall governance reform aimed at enhancing universities' autonomy. Researchers and economic entrepreneurs tend, however, to underestimate the political dimension of accreditation and evaluation when they consider the contribution of quality assurance to the…

  15. [Quality assurance and quality improvement in medical practice. Part 1. Definition and importance of quality in medical practice].

    Science.gov (United States)

    Godény, Sándor

    2012-01-22

    In Hungary, financing of healthcare has decreased relative to the GDP, while the health status of the population is still ranks among the worst in the European Union. Since healthcare financing is not expected to increase, the number of practicing doctors per capita is continuously decreasing. In the coming years, it is an important question that in this situation what methods can be used to prevent further deterioration of the health status of the Hungarian population, and within this is the role of the quality approach, and different methods of quality management. In the present and the forthcoming two articles those standpoints will be summarized which support the need for the integration of quality assurance in the everyday medical practice. In the first part the importance of quality thinking, quality management, quality assurance, necessity of quality measurement and improvement, furthermore, advantages of the quality systems will be discussed.

  16. Manpower requirements for quality assurance during operation

    International Nuclear Information System (INIS)

    Pratt, J.M.; Sollenberger, L.G.

    1982-01-01

    As a result of the Three Mile Island accident and the findings presented in various investigatory reports, some fundamental changes are taking place in the role and scope of quality assurance. Recent changes to United States national codes, guides and standards are analysed in order to identify the principles involved. This analysis shows that the scope of the programme is being extended beyond the equipment designated 'nuclear safety related' and greater emphasis is being placed upon the independent verification of the satisfactory performance of activities affecting safety. Such fundamental changes could lead to a significant increase in the number of quality assurance personnel required to support an operating nuclear power plant. The evolving quality assurance organization at Three Mile Island is used to illustrate how these fundamental changes could affect the quality assurance organization and manpower requirements. (author)

  17. Quality assurance in biomarker measurement.

    Science.gov (United States)

    Aitio, A; Apostoli, P

    1995-05-01

    Quality assurance (QA) concerns the validity of all the analytical processes (from collection of the samples to interpretation of the results). It is not an abstract concept but must be adapted to the different situations such as the different exposure levels, the different analytical methods, and the context of use (risk assessment procedures, research, routine determinations). The main requirements in QA programmes regard the control of all the known sources of preanalytical and analytical variations, while the instruments with which adequate QA can be implemented are the certified materials and the quality control programmes (quality manual, internal and external quality controls). Another important concept in QA is that measurements must be placed a different metrological levels: at the highest there are the methods (definitive, reference) to be used for assessing accuracy of routine methods. QA programmes should enable a grading of biomarkers (from experimental only to full evaluated) and of the laboratories in order to identify the significance of the test and to assess the level at which a laboratory could operate.

  18. Guidelines for comprehensive quality assurance in brachytherapy

    International Nuclear Information System (INIS)

    Goldson, A.L.; Nibhanupudy, J.R.

    1984-01-01

    Brachytherapy treatment techniques can provide significant improvement in local control and overall survival, but only when quality assurance can be guaranteed. To establish brachytherapy quality assurance, basic requirements for three predetermined subdivisions of clinical institutions will be forwarded. These are: (1) centers having minimum requirements to provide brachytherapy, (2) intermediate centers such as regional or community hospitals, and (3) optimal centers such as university hospital and cancer centers. This presentation will highlight personnel needs, equipment requirements, academic activities, clinical experience with these systems and proposed quality assurance guidelines

  19. Commissioning quality assurance for nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig.

  20. Commissioning quality assurance for nuclear power plants

    International Nuclear Information System (INIS)

    1986-09-01

    This standard contains the requirements for the quality assurance program applicable to the commissioning phase of a nuclear power plant. This standard embodies the relevant quality assurance requirements of CSA Standard CAN3-N286.0, and is the governing Standard for commissioning quality assurance activities in the event of any conflicting requirements. This Standard applies to the commissioning of safety-related equipment, systems, and structures as identified by the owner. It may be applied to other equipment, systems, and structures at the discretion of the owner. 1 fig

  1. Quality assurance measures in interventional radiology

    International Nuclear Information System (INIS)

    Heuser, L.

    1999-01-01

    The quality assurance of treatment measures is legally required but as yet not generally established in practice. For interventional radiology, the introduction of quality assurance for PTA of arteries of the lower limbs is planned for January 1999. It is reasonable to subject at least the most important and/or most frequently performed interventions to quality management. In the present article, the term quality in the management of diseases is defined and the system of total quality management discussed at the levels structure, process, and results. For its application, parameters of quality measurement in the form of standards, criteria, and characteristic values are necessary and must be laid down by a team of experts on the basis of subjective experience and/or results in the literature. Practical quality assurance takes place not only within a clinic but also externally by comparison with other centers. Data collection and evaluation requires high-performance software that will be continuously improved, expanded, and adapted to current needs during regular meetings between the various users. (orig.) [de

  2. [Quality assurance and quality management in intensive care].

    Science.gov (United States)

    Notz, K; Dubb, R; Kaltwasser, A; Hermes, C; Pfeffer, S

    2015-11-01

    Treatment success in hospitals, particularly in intensive care units, is directly tied to quality of structure, process, and outcomes. Technological and medical advancements lead to ever more complex treatment situations with highly specialized tasks in intensive care nursing. Quality criteria that can be used to describe and correctly measure those highly complex multiprofessional situations have only been recently developed and put into practice.In this article, it will be shown how quality in multiprofessional teams can be definded and assessed in daily clinical practice. Core aspects are the choice of a nursing theory, quality assurance measures, and quality management. One possible option of quality assurance is the use of standard operating procedures (SOPs). Quality can ultimately only be achieved if professional groups think beyond their boundaries, minimize errors, and establish and live out instructions and SOPs.

  3. Quality assurance in Hanford site defense waste operations

    International Nuclear Information System (INIS)

    Wojtasek, R.D.

    1989-01-01

    This paper discusses quality assurance as an integral part of conducting waste management operations. The storage, treatment, and disposal of radioactive and non- radioactive hazardous wastes at Hanford are described. The author reports that quality assurance programs provide confidence that storage, treatment, and disposal facilities and systems perform as intended. Examples of how quality assurance is applied to Hanford defense waste operations are presented

  4. An overview of quality assurance

    International Nuclear Information System (INIS)

    Morris, I.T.

    1983-01-01

    A good quality assurance program seeks to minimise radiation exposure and maximise image quality. Factors considered are equipment performance, films and screens, film processing, viewing conditions and film repeats

  5. The Concepts of Quality, Quality Assurance and Quality Enhancement

    Science.gov (United States)

    Elassy, Noha

    2015-01-01

    Purpose: This paper aims to critically review and discuss different definitions of the concepts of quality, quality assurance (QA) and quality enhancement (QE) in higher education (HE) with presenting critical perspectives of the literature. Design/methodology/approach: The paper looks at literature concerns with the meaning of quality, QA and QE,…

  6. Auditing of quality assurance programs for nuclear power plants - September 1980 - (Rev.1)

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    Appendix B, Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants, to 10 CFR Part 50, Domestic Licensing of Production and Utilization Facilities, establishes overall quality assurance requirements for the design, construction, and operation of structures, systems, and components of nuclear power plants important to safety. Criterion XVIII, Audits, of Appendix B to 10 CFR Part 50 establishes requirements for conducting audits of the quality assurance program. This guide describes a method acceptable to the NRC staff for complying with the Commission's regulations with regard to auditing of quality assurance programs for nuclear power plants. The Advisory Committee on Reactor Safeguards has been consulted concerning this guide and has concurred in the regulatory position

  7. Quality assurance records system

    International Nuclear Information System (INIS)

    1979-01-01

    This Safety Guide was prepared as part of the Agency's programme, referred to as the NUSS programme, for establishing Codes of Practice and Safety Guides relating to nuclear power plants. It supplements the IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants (IAEA Safety Series No.50-C-QA), which requires that for each nuclear power plant a system for the generation, identification, collection, indexing, filing, storing, maintenance and disposition of quality assurance records shall be established and executed in accordance with written procedures and instructions. The purpose of this Safety Guide is to provide assistance in the establishment and operation of such a system. An orderly established and maintained records system is considered to be part of the means of providing a basis for an appropriate level of confidence that the activities which affect the quality of a nuclear power plant have been performed in accordance with the specific requirements and that the required quality has been achieved and is maintained

  8. Quality assurance of radiopharmaceuticals-specifications and test procedures

    International Nuclear Information System (INIS)

    Baldas, J.; Bonnyman, J.; Pojer, P.M.

    1981-08-01

    This report is a compilation of test methods used and specifications adopted for the Radiopharmaceutical Quality Assurance Test Programme conducted by the Australian Radiation Laboratory. In some cases test procedures described have been taken from various Pharmacopoeias or methods published in the literature. In other cases test methods have been developed at the ARL

  9. New techniques in quality assurance

    International Nuclear Information System (INIS)

    Fornicola, J.C.

    1987-01-01

    GPU Nuclear Corp. has a multifaceted quality assurance (QA) program. This program includes a comprehensive QA organization to help ensure its implementation. The QA organization employs various techniques in assuring quality at GPU Nuclear. These techniques not only include the typical QA/quality-control verification activities, i.e., QA engineering, quality control, and audits, but also include some new innovative techniques. Several new techniques have been developed for verifying activities. These techniques include monitoring and functional audits of safety systems. Several new techniques for assessing performance and adequacy and effectiveness of plant and QA programs, such as plant assessments and QA systems engineering evaluations, have also been developed. This paper provides an overview of these and other new techniques being employed by GPU Nuclear's QA organization

  10. MCNP trademark Software Quality Assurance plan

    International Nuclear Information System (INIS)

    Abhold, H.M.; Hendricks, J.S.

    1996-04-01

    MCNP is a computer code that models the interaction of radiation with matter. MCNP is developed and maintained by the Transport Methods Group (XTM) of the Los Alamos National Laboratory (LANL). This plan describes the Software Quality Assurance (SQA) program applied to the code. The SQA program is consistent with the requirements of IEEE-730.1 and the guiding principles of ISO 900

  11. Quality assurance in TL monitoring of occupational radiation workers in Andhra Pradesh

    International Nuclear Information System (INIS)

    Padma Savitri, P.; Kamble, M.K.; Roy, Madhumita; Reddy, K.S.; Mahajan, J.M.

    2005-01-01

    TLD Services are rendered for personnel dosimetry to Nuclear Fuel Complex, Atomic Minerals Division, Electronic Corporation of India Limited, National Centre for Characterization of Materials, JONAKI, Medical, Research and Industrial institutions of Andhra Pradesh by TLD Unit, Nuclear Fuel Complex, Hyderabad. To ensure the satisfactory performance of the unit, it is mandatory to participate in Quality Assurance Programme periodically. Setting the rules for the Quality Assurance Programme and implementing them systematically in the service requires considerable thought and effort. Quality Assurance and Quality Check Program addressed administrative data/information, equipment checking, issue/processing of dosimeters, dose evaluation, record keeping, reporting, traceability and reproducibility. In this paper results of Quality Assurance Checks conducted by TLD Unit, NFC as well as C and DRS, RPAD, BARC, Mumbai for the last six years and Internal Quality Checks conducted within TLD Unit, NFC are presented and discussed. Systematic errors in dose evaluation were identified and minimized. Methods to improve the performance are also suggested. (author)

  12. Quality assurance program plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Boom, R.J.

    1995-12-01

    This Quality Assurance Program Plan identifies quality assurance program requirements and addresses the various Westinghouse Hanford Company organizations and their particular responsibilities in regards to sample and data handling of radiological airborne emissions. This Quality Assurance Program Plan is prepared in accordance with and to written requirements

  13. Statistical process control for radiotherapy quality assurance

    International Nuclear Information System (INIS)

    Pawlicki, Todd; Whitaker, Matthew; Boyer, Arthur L.

    2005-01-01

    Every quality assurance process uncovers random and systematic errors. These errors typically consist of many small random errors and a very few number of large errors that dominate the result. Quality assurance practices in radiotherapy do not adequately differentiate between these two sources of error. The ability to separate these types of errors would allow the dominant source(s) of error to be efficiently detected and addressed. In this work, statistical process control is applied to quality assurance in radiotherapy for the purpose of setting action thresholds that differentiate between random and systematic errors. The theoretical development and implementation of process behavior charts are described. We report on a pilot project is which these techniques are applied to daily output and flatness/symmetry quality assurance for a 10 MV photon beam in our department. This clinical case was followed over 52 days. As part of our investigation, we found that action thresholds set using process behavior charts were able to identify systematic changes in our daily quality assurance process. This is in contrast to action thresholds set using the standard deviation, which did not identify the same systematic changes in the process. The process behavior thresholds calculated from a subset of the data detected a 2% change in the process whereas with a standard deviation calculation, no change was detected. Medical physicists must make decisions on quality assurance data as it is acquired. Process behavior charts help decide when to take action and when to acquire more data before making a change in the process

  14. Troublesome Knowledge: A New Approach to Quality Assurance in Mental Health Nursing Education.

    Science.gov (United States)

    Leidl, Donald M

    2018-01-01

    Background Quality assurance and quality enhancement processes in nursing education are vital to the establishment of a strong program. Existing quality assurance methods in nursing education such as professional self-regulation and external examination rely on provincial and national nursing associations for evaluation, putting minimal responsibility and accountability on internal program examiners. Threshold concepts and troublesome knowledge provide a framework as outlined by Land that utilizes internal examiners from both student and faculty groups and represents an alternative to traditional quality assurance in nursing education. Purpose To identify troublesome mental health nursing content in a nursing curriculum by exploring students and faculty perspectives. Method A sequential mixed methods design that utilized surveys and focus groups to explore student and faculty perspectives on troublesome mental health nursing content. Results The project data were able to be organized into five main content themes that were identified as being troublesome: the spectrum of mental illness, therapeutic relationships and boundaries, praxis, professionalism in nursing, and brain chemistry and its management. Conclusion The findings from this project are unique to the program of review but show the potential of this new approach to quality assurance and program enhancement initiatives in nursing education.

  15. The selective application of quality assurance activities to nuclear power plant items and services

    International Nuclear Information System (INIS)

    Anderson, J.W.

    1982-01-01

    The definition of quality assurance and the criteria for a quality assurance programme that are contained in both national and international codes and standards provide the principle of selective application of quality assurance activities for cost-effective results. The effective implementation of this principle requires a systematic and disciplined methodology that should be established by or for the owner at the beginning of a nuclear power plant project. The methodology that has proven to be successful generally includes a uniform method of classifying plant items and services at their lowest level of unit assembly and using that classification in the selection of applicable quality assurance activities and the specification of appropriate requirements for those activities. The applicable quality assurance activities are those to be implemented by the organizations designing, manufacturing, installing and operating plant items or performing support services. The methods and techniques provided illustrate the methodology and are one way by which a nuclear power plant project may translate the principle into application in order to achieve the desired results. (author)

  16. Quality assurance in education: The role of ICT and quality control ...

    African Journals Online (AJOL)

    Quality assurance in education is perceived in this paper to be a product of the impact of information and communication technologies as well as the statutory control measures especially in tertiary institutions in Nigeria. The paper reviews the concept of quality and quality assurance and their general application to ...

  17. 7 CFR 90.102 - Quality assurance review.

    Science.gov (United States)

    2010-01-01

    ... procedures; (3) A review of records for the calibration and maintenance of equipment; (4) A review of records..., Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE (CONTINUED) COMMODITY LABORATORY TESTING PROGRAMS INTRODUCTION Quality Assurance § 90.102 Quality assurance review. (a) Each laboratory performing tests and...

  18. Quality assurance - the key to the future

    Energy Technology Data Exchange (ETDEWEB)

    Rix, C [British Coal Corporation, London (UK)

    1992-05-01

    Quality assurance seeks to achieve diligence and attention to detail, which can have substantial effects including reduced costs and improved performance, as well as greater customer satisfaction. British Coal has a policy of quality assurance to BS5750 at all collieries and despatch points, to help maintain its competitive position, to respond to customer requirements, and to continue the drive for reduced costs. A pilot exercise was undertaken at Maltby and Kellingley collieries, and at Oxcroft and Gwaun-cae-Gurwen opencast despatch points, in order to gain sufficient experience to allow rapid implementation of quality assurance at all sites.

  19. Quality Assurance Training Tracking (QATTS)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Training Tracking System (QATTS) which tracks Quality Assurace training given by R7 QA staff to in-house...

  20. 42 CFR 441.474 - Quality assurance and improvement plan.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 4 2010-10-01 2010-10-01 false Quality assurance and improvement plan. 441.474... improvement plan. (a) The State must provide a quality assurance and improvement plan that describes the State... pursue opportunities for system improvement. (b) The quality assurance and improvement plan shall also...

  1. Variables Affecting a Level of Practice and Quality of Educational Quality Assurance in Basic Education Schools

    Directory of Open Access Journals (Sweden)

    Jakkapong Prongprommarat

    2016-10-01

    Full Text Available The purposes of this research were to study the Level of Practice and Quality of Educational Quality Assurance in Basic Education Schools of the Office of the Basic Education Commission. The sample consisted of 60 secondnary schools in Office of the basic Education Commission in the provinces of Chaiyaphum, Nakhon Ratchasima, Burirum, Surin and Khon Kaen were drawn by using proportionally with the number of teachers in each school. The data were collected by using (1 the questionnaire on the acting of educational quality assurance in basic education schools. (2 the record form the external assessment of the office for National Education Standards and Quality Assessment, (3 the questionnaire on the director leadership, (2 test of the directors and teachers attitudes towards educational quality assurance, (5 test of the directors and teachers inquirying motive, (6 test of the directors and teachers working responsibility, and (7 the questionnaire on the directors and teachers cooperative. The statistical methods used to analysis the data were mean, standard deviation, coefficient of variation and path analysis. The findings revealed that: 1. The level of acting of educational quality assurance in basic education schools was at a high level. There was just a fairly difference in acting of educational quality assurance in basic education schools. 2. The level of external quality assessment in basic education schools was at a good level. There was just a little difference in external quality assessment in basic education schools. 3. The variables affecting level of acting of educational quality assurance in basic education schools were the level of the school directors attitudes towards educational quality assurance (β = 0.10, the level of the school directors working responsibility (β = 0.13, the level of the teacher attitudes towards educational quality assurance (β = 0.23 and the level of the teachers inquirying motive (β = 0.49 These four

  2. Quality assurance in digital radiography

    International Nuclear Information System (INIS)

    Busch, H.P.; Lehmann, K.J.

    1989-01-01

    At present, there is no standard way of evaluating performance characteristics of digital radiography systems. Continuous measurements of performance parameters are necessary in order to obtain images of high quality. Parameters of quality assurance in digital radiography, which can be evaluated with simple, quick methods, are spatial resolution, low-contrast detectability, dynamic range and exposure dose. Spatial resolution was determined by a lead bar pattern, whereas the other parameters were measured by commercially available phantoms. Performance measurements of 10 digital subtraction angiography (DSA) units and one digital radiography system for unsubtracted digital radiography were assessed. From these results, recommendations for performance parameter levels will be discussed. (author)

  3. Elements of quality assurance in environmental surveillance

    International Nuclear Information System (INIS)

    Johnson, L.J.

    1975-01-01

    Qualities of an environmental surveillance program requiring control or assurance are reviewed. Requirements of accuracy, reproducibility, sensitivity, acceptability, and time and cost effectiveness are qualities discussed. The controls applicable to sample collection, handling, chemical analysis, measurement and data presentation are identified and discussed as they pertain to environmental monitoring. Quality assurance program recommendations for developing and reporting environmental surveillance data are provided

  4. Grid Technology and Quality Assurance

    International Nuclear Information System (INIS)

    Rippa, A.; Manieri, A.; Begin, M.E.; Di Meglio, A.

    2007-01-01

    Grid is one of the potential architectures of the coming years to support both the research and the commercial environment. Quality assurance techniques need both to adapt to these new architectures and exploit them to improve its effectiveness. Software quality is a key issue in the Digital Era: Industries as well as Public Administrations devote time to check and verify the quality of ICT products and services supplied. The definition of automatic measurement of quality metrics is a key point for implementing effective QA methods. In this paper we propose a quality certification model, named Grid-based Quality Certification Model (GQCM), that uses automatically calculable metrics to asses the quality of software applications; this model has been developed within the ETICS SSA4 activities and exploit grid technology for full automation of metrics calculation. It is however designed to be generic enough such that it can be implemented using any automatic build and test tool. (Author)

  5. Quality Control and Quality Assurance of Radiation Oncology

    International Nuclear Information System (INIS)

    Abaza, A.

    2016-01-01

    Radiotherapy (RT) has played important roles in cancer treatment for more than one century. The development of RT techniques allows high-dose irradiation to tumors while reducing the radiation doses delivered to surrounding normal tissues. However, RT is a complex process and involves understanding of the principles of medical physics, radiobiology, radiation safety, dosimetry, radiation treatment planning, simulation and interaction of radiation with other treatment modalities. Each step in the integrated process of RT needs quality control and quality assurance (QA) to prevent errors and to ensure that patients will receive the prescribed treatment correctly. The aim of this study is to help the radio therapists in identifying a system for QA that balances patient safety and quality with available resources. Recent advances in RT focus on the need for a systematic RT QA program that balances patient safety and quality with available resources. It is necessary to develop more formal error mitigation and process analysis methods, such as failure mode and effect analysis (FMEA), to focus available QA resources optimally on the process components. External audit programs are also effective. Additionally, Clinical trial QA has a significant role in enhancing the quality of care. The International Atomic Energy Agency (IAEA) has operated both an on-site and off-site postal dosimetry audit to improve practice and to assure the dose from RT equipment. Both postal dosimetry audit and clinical trial RTQA, especially for advanced technologies, in collaboration with global networks, will serve to enhance patient safety and quality of care

  6. Quality assurance during the manufacture of nuclear power plant components

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    Apart from the special requirements of quality assurance in the production of components for the nuclear industry, in particular nuclear power stations, the author discusses special methods of quality control in the testing of welded joints. (TK) [de

  7. Quality assurance in the design

    International Nuclear Information System (INIS)

    Edelmann, J.

    1980-01-01

    System- and product-related quality assurance measures are completing one another. Certainly it is possible to detect a lot of defects in the single technical document by well controlled product related quality inspections and to avoid the consequences of these defects; but also a not unimportant part of defects and deviations has its origin in system linked deficiencies. The latter can be detected more easily and more securely by means of system related reviews (System audit, Product audit). But also the sole implementation of system related quality assurance measures keeps the danger to get stuck only in formality and to loose all references to the specific characteristics of the product. (orig./RW)

  8. Quality Assurance In Radioactivity Measurements

    International Nuclear Information System (INIS)

    Riekstina, D.; Veveris, O.; Smilskalne, G.

    2007-01-01

    The credibility of obtained results is ensured by the quality assurance and control. The main requisitions involved in the quality assurance of the laboratory according to the requirements of LVS EN ISO/IEC 17025:2005 are: 1) the use of calibrated equipment only; 2) the regular and long-time use of reference materials in the control of equipment; 3) the estimation of uncertainty sources and determination of uncertainties within the given interval of credibility; 4) the validation and verification. The very important requirement is regular participation in the interlaboratory intercomparison exercises that makes it possible to estimate and find possible error sources and carry out the corrective actions. The measurements of the radioactivity of Cs-137, Co-60, H-3, the natural radioactive nuclides as well as other radionuclides in different environmental (soil, precipitation, different types of water, needles, et al.) samples, and in various radioactive polluted objects are carried out in the Laboratory of Radiation physics. The quality assurance system was implemented in our laboratory in 2000. Since 1999 laboratory is regular participant in the interlaboratory intercomparison exercises, organized by the RISO National Laboratory (Denmark) and IAEA (Vienna). The paper shows the laboratory's system of quality assurance and its implementation. We have the internal quality audit program that takes into account the requirements of LVS EN ISO/IEC 17025: 2005, but the main attention is paid to the intercomparison of the results of analyses of laboratories, their evaluation and interpretation. Only credible and justified results can be the basis for further use in any field, thus making it possible to make legitimate decisions. (Authors)

  9. quality assurance systems in nuclear fuel procurement and manufacturing

    International Nuclear Information System (INIS)

    Can, S.

    1997-01-01

    Quality is the totality of features and characteristics of a product or service that bear on its ability to satisfy stated or implied needs. Quality control is activities and techniques used to fulfill the requirements of quality. Quality assurance is a system and its main components are requirements. QA program, organization and responsibilities, design and verification, material and its control, manufacturing and process control, inspections, audits and documents: manuals, specifications, instructions. Quality assurance systems are largely based on ISO 9000 series of the International Standards Organization. ISO 9000 series has been adopted and published by Turkish Standards Institute as TS-ISO 9000. International Atomic Energy Agency also published a guide (50-SG-QA11) ''Quality Assurance in the Procurement, Design and Manufacture of Nuclear Fuel Assemblies'' in the safety guide series. In this study the role of quality control in quality assurance systems, inspection and test plans and acceptance and nonconformance quality levels will be explained in relation to nuclear fuel production. Examples of applications in quality assurance systems based on ISO 9000 will be given

  10. Management control and quality assurance during plant operation

    International Nuclear Information System (INIS)

    Modemann, G.; Ettemeyer, R.; Stephan, W.

    1980-01-01

    The present paper deals with basic aspects of quality assurance for owners of nuclear power plants, with quality assurance for plant operation and with consequences from KTA regulatory requirements. (RW)

  11. Quality assurance: Importance of systems and standard operating procedures.

    Science.gov (United States)

    Manghani, Kishu

    2011-01-01

    It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  12. Quality assurance: Importance of systems and standard operating procedures

    Directory of Open Access Journals (Sweden)

    Kishu Manghani

    2011-01-01

    Full Text Available It is mandatory for sponsors of clinical trials and contract research organizations alike to establish, manage and monitor their quality control and quality assurance systems and their integral standard operating procedures and other quality documents to provide high-quality products and services to fully satisfy customer needs and expectations. Quality control and quality assurance systems together constitute the key quality systems. Quality control and quality assurance are parts of quality management. Quality control is focused on fulfilling quality requirements, whereas quality assurance is focused on providing confidence that quality requirements are fulfilled. The quality systems must be commensurate with the Company business objectives and business model. Top management commitment and its active involvement are critical in order to ensure at all times the adequacy, suitability, effectiveness and efficiency of the quality systems. Effective and efficient quality systems can promote timely registration of drugs by eliminating waste and the need for rework with overall financial and social benefits to the Company.

  13. Quality Assurance in Postgraduate Education. ENQA Workshop Report 12

    Science.gov (United States)

    Bitusikova, Alexandra; Bohrer, Janet; Borosic, Ivana; Costes, Nathalie; Edinsel, Kerim; Hollander, Karoline; Jacobsson, Gunilla; Jakopovic, Ivan Filip; Kearney, Mary-Louise; Mulder, Fred; Negyesi, Judith; Pietzonka, Manuel

    2010-01-01

    The present report follows an ENQA (European Association for Quality Assurance in Higher Education) Workshop on Quality Assurance and Postgraduate Education, hosted by the Romanian Agency for Quality Assurance in Higher Education (ARACIS) in Brasov, Romania on 12-13 March 2009. The workshop was an excellent opportunity for ENQA members to exchange…

  14. Quality Assurance of Quality Assurance Agencies from an Asian Perspective: Regulation, Autonomy and Accountability

    Science.gov (United States)

    Hou, Angela Yung-Chi; Ince, Martin; Tsai, Sandy; Chiang, Chung Lin

    2015-01-01

    As quality guardians of higher education, quality assurance agencies are required to guarantee the credibility of the review process and to ensure the objectivity and transparency of their decisions and recommendations. These agencies are therefore expected to use a range of internal and external approaches to prove the quality of their review…

  15. Quality assurance in the creative enterprise: an appraisal of select ...

    African Journals Online (AJOL)

    Thus, the aim of this study is how to assure quality in the creative process ... study and content analysis research approaches of the qualitative research method. The researchers concluded that adherence to theory can build and sustain quality ...

  16. Software quality assurance plan for PORFLOW-3D

    International Nuclear Information System (INIS)

    Maheras, S.J.

    1993-03-01

    This plan describes the steps taken by the Idaho National Engineering Laboratory Subsurface and Environmental Modeling Unit personnel to implement software quality assurance procedures for the PORFLOW-3D computer code. PORFLOW-3D was used to conduct radiological performance assessments at the Savannah River Site. software quality assurance procedures for PORFLOW-3D include software acquisition, installation, testing, operation, maintenance, and retirement. Configuration control and quality assurance procedures are also included or referenced in this plan

  17. Development of the system based code. v. 5. Method of margin exchange. pt. 2. Determination of quality assurance index based on a 'Vector Method'

    International Nuclear Information System (INIS)

    Asayama, Tai

    2003-03-01

    For the commercialization of fast breeder reactors, 'System Based Code', a completely new scheme of a code on structural integrity, is being developed. One of the distinguished features of the System Based Code is that it is able to determine a reasonable total margin on a structural of system, by allowing the exchanges of margins between various technical items. Detailed estimation of failure probability of a given combination of technical items and its comparison with a target value is one way to achieve this. However, simpler and easier methods that allow margin exchange without detailed calculation of failure probability are desirable in design. The authors have developed a simplified method such as a 'design factor method' from this viewpoint. This report describes a 'Vector Method', which was been newly developed. Following points are reported: 1) The Vector Method allows margin exchange evaluation on an 'equi-quality assurance plane' using vector calculation. Evaluation is easy and sufficient accuracy is achieved. The equi-quality assurance plane is obtained by a projection of an 'equi-failure probability surface in a n-dimensional space, which is calculated beforehand for typical combinations of design variables. 2) The Vector Method is considered to give the 'Quality Assurance Index Method' a probabilistic interpretation. 3) An algebraic method was proposed for the calculation of failure probabilities, which is necessary to obtain a equi-failure probability surface. This method calculates failure probabilities without using numerical methods such as Monte Carlo simulation or numerical integration. Under limited conditions, this method is quite effective compared to numerical methods. 4) An illustration of the procedure of margin exchange evaluation is given. It may be possible to use this method to optimize ISI plans; even it is not fully implemented in the System Based Code. (author)

  18. Data Mining Methods Applied to Flight Operations Quality Assurance Data: A Comparison to Standard Statistical Methods

    Science.gov (United States)

    Stolzer, Alan J.; Halford, Carl

    2007-01-01

    In a previous study, multiple regression techniques were applied to Flight Operations Quality Assurance-derived data to develop parsimonious model(s) for fuel consumption on the Boeing 757 airplane. The present study examined several data mining algorithms, including neural networks, on the fuel consumption problem and compared them to the multiple regression results obtained earlier. Using regression methods, parsimonious models were obtained that explained approximately 85% of the variation in fuel flow. In general data mining methods were more effective in predicting fuel consumption. Classification and Regression Tree methods reported correlation coefficients of .91 to .92, and General Linear Models and Multilayer Perceptron neural networks reported correlation coefficients of about .99. These data mining models show great promise for use in further examining large FOQA databases for operational and safety improvements.

  19. The challenge of Quality Assurance

    International Nuclear Information System (INIS)

    Simon, R.; Price, M.S.T.; Krischer, W.

    1985-01-01

    The safe terminal containment of hazardous wastes cannot only rely upon the geographic remoteness and the arid climates of the repository sites. Radioactive and permanently toxic chemical wastes must by prevented from returning to the human environment by natural and engineered barriers. The long-term integrity of these barriers and the safety of waste emplacement operation will be controlled by systematic actions under the common objective of Quality Assurance (QA). The following paper presents the aims of QA in the design and production of waste packages. It lists the most relevant acceptance criteria and regulatory requirements, investigates the institutional and technical problems of carrying out Quality Assurance and presents suggestions for establishing suitable organizational structures and technical programmes to provide adequate confidence in the safe nature and the performance of waste packages. In view of the technical difficulties of verifying the compliance of industrially produced waste forms with the acceptance criteria, the CEC has laid emphasis on the development of appropriate test methods in its last R and D programme. First results of the work are reviewed in the context of international progress in this field

  20. SGHWR - quality assurance documentation

    International Nuclear Information System (INIS)

    Garrard, R.S.; Caulfield, J.

    1976-01-01

    The quality assurance program for a modern power station such as an SGHWR type reactor plant must include a record of quality achievement. The case history record which is evidence of the actual quality of the plant and is a data bank of design, manufacture, and results of inspections and tests, is described. Documentation distribution, which keeps all key areas informed of plant item quality status, and the retrieval and storage of information, are briefly discussed. (U.K.)

  1. Quality assurance and reliability

    International Nuclear Information System (INIS)

    Normand, J.; Charon, M.

    1975-01-01

    Concern for obtaining high-quality products which will function properly when required to do so is nothing new - it is one manifestation of a conscientious attitude to work. However, the complexity and cost of equipment and the consequences of even temporary immobilization are such that it has become necessary to make special arrangements for obtaining high-quality products and examining what one has obtained. Each unit within an enterprise must examine its own work or arrange for it to be examined; a unit whose specific task is quality assurance is responsible for overall checking, but does not relieve other units of their responsibility. Quality assurance is a form of mutual assistance within an enterprise, designed to remove the causes of faults as far as possible. It begins very early in a project and continues through the ordering stage, construction, start-up trials and operation. Quality and hence reliability are the direct result of what is done at all stages of a project. They depend on constant attention to detail, for even a minor piece of poor workmanship can, in the case of an essential item of equipment, give rise to serious operational difficulties

  2. Quality assurance of radiation therapy machines

    International Nuclear Information System (INIS)

    Francois, P.

    2002-01-01

    Due to the modifications of components, to unexpected breakage of elements or to electronic dysfunctions, the performance of radiotherapy machines may decrease with age. Quality Assurance procedures and maintenance program are necessary to guarantee the performances. For linear accelerators, modus operandi of control tests and their frequency are based on regulations and recommendations widely published, that are presented here. Concerning accessories, especially those recently developed (multi-leaf collimators, dynamic wedges,...), recommendations remains to be defined. Simple tests are proposed. Concerning numerical imaging systems, widely used for three dimensional dosimetry, image quality and geometry controls must be performed with fantom tests. For portal imaging, a quality assurance program is proposed. A strict and complete Quality Assurance program is essential to guarantee quality and safety of the treatment. A regular control of linear accelerator is one of the important component of this program. It suppose the implementation of permanent tests procedures, periodically modified following technological progresses and treatment techniques. Measurements must be sensible to variations below the tolerance level defined during the installation process. The analysis of the variations of measurements with time are an objective criterion of quality. (author)

  3. Quality assurance during operation of nuclear power plants

    International Nuclear Information System (INIS)

    1994-01-01

    The general requirements applicable to the quality assurance of the Finnish nuclear power plants are presented in the Council of State Decision (395/91) and in the guide YVL 1.4. This guide specifies the quality assurance requirements to be applied during the operation of the nuclear power plants as well as of the other nuclear facilities. Quality assurance applies to all the activities and organizations with a bearing on the safe operation of the nuclear power plants. (5 refs.)

  4. Definition of a material's quality assurance level

    International Nuclear Information System (INIS)

    Fride, B.

    1990-01-01

    The architecture of expert system COIN (French acronym for classification of Operation Tools) is presented. The system was developed for providing assistance in the determination of the quality level required by the operation tools and their components. Those tools are applied in the maintenance operations in the nuclear power plants and are classified under a Quality Assurance procedure. The characteristics of COIN, its influence on a problem solving method, and the steps of the system's development are summarized [fr

  5. Quality assurance issues and PACS

    NARCIS (Netherlands)

    Banta, H.D.

    1992-01-01

    Quality assessment and assurance is a growing concern in all areas of health care. The concern is fueled by a body of evidence that indicates that quality of care is not optimal, and in many instances, is unacceptably low. Although different standards for quality have been proposed, health outcome

  6. Radiation safety and quality control assurance in X-ray diagnostics 1998

    International Nuclear Information System (INIS)

    Servomaa, A.

    1998-03-01

    The report is based on a seminar course of lectures 'Radiation safety and quality assurance in X-ray diagnostics 1998' organized by the Radiation and Nuclear Safety Authority (STUK) in Finland. The lectures included actual information on X-ray examinations: methods of quality assurance, methods of measuring and calculating patient doses, examination frequencies, patient doses, occupational doses, and radiation risks. Paediatric X-ray examinations and interventional procedures were the most specific topics. The new Council Directive 97/43/Euratom on medical exposure, and the European Guidelines on quality criteria for diagnostic radiographic images, were discussed in several lectures. Lectures on general radiation threats and preparedness, examples of radiation accidents, and emergency preparedness in hospitals were also included. (editor)

  7. Quality Assurance 1992-2012

    Science.gov (United States)

    Brown, Roger

    2012-01-01

    As the author's contribution to a series marking the Golden Jubilee of the Association of University Administrators, he reflects on changes in quality assurance over the past twenty years and speculates on what the future may hold for quality as the association moves into a new and very different competitive regime. He begins by discussing the…

  8. Current quality assurance concepts and considerations for quality control of in-clinic biochemistry testing.

    Science.gov (United States)

    Lester, Sally; Harr, K E; Rishniw, Mark; Pion, Paul

    2013-01-15

    Quality assurance is an implied concept inherent in every consumer's purchase of a product or service. In laboratory testing, quality assurance encompasses preanalytic (sampling, transport, and handling prior to testing), analytic (measurement), and postanalytic (reporting and interpretation) factors. Quality-assurance programs require that procedures are in place to detect errors in all 3 components and that the procedures are characterized by both documentation and correction of errors. There are regulatory bodies that provide mandatory standards for and regulation of human medical laboratories. No such regulations exist for veterinary laboratory testing. The American Society for Veterinary Clinical Pathology (ASVCP) Quality Assurance and Laboratory Standards Committee was formed in 1996 in response to concerns of ASVCP members about quality assurance and quality control in laboratories performing veterinary testing. Guidelines for veterinary laboratory testing have been developed by the ASVCP. The purpose of this report was to provide an overview of selected quality-assurance concepts and to provide recommendations for quality control for in-clinic biochemistry testing in general veterinary practice.

  9. Endorectal high dose rate brachytherapy quality assurance

    International Nuclear Information System (INIS)

    Devic, S.; Vuong, T.; Evans, M.; Podgorsak, E.

    2008-01-01

    We describe our quality assurance method for preoperative high dose rate (HDR) brachytherapy of endorectal tumours. Reproduction of the treatment planning dose distribution on a daily basis is crucial for treatment success. Due to the cylindrical symmetry, two types of adjustments are necessary: applicator rotation and dose distribution shift along the applicator axis. (author)

  10. Quality Assurance Review of SKB's Copper Corrosion Experiments

    International Nuclear Information System (INIS)

    Baldwin, Tamara D.; Hicks, Timothy W.

    2010-06-01

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried out with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. The former named authority, SKI, has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This quality assurance review is focused on the work of copper corrosion being conducted in at SKB's Hard Rock Laboratory (HRL) in Aespoe, LOT and Miniature canister (Minican) experiments. In order for the reviewers to get a broad understanding of the issue of copper corrosion both SKB reports as well as the viewpoint of MKG was collected prior to commencement of the actual review task. The purpose of this project is to assess SKB's quality assurance with the view of providing input for the preparation of the SR-Site safety assessment. This has been achieved by examination of the corrosion part of the LOT and Minican experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. The same approach for quality assurance reviews has been used earlier in similar review tasks. During the quality review of the selected projects, several QA- related issues of different degree of severity was noted by the reviewers. The most significant finding was that SKB has chosen to present only selected real-time corrosion monitoring data in TR-09-20. This was surprising and SSM expect that SKB will analyse the reason for this thoroughly. The reviewers also made other observations which can be

  11. A pioneering application of NQA-1 quality assurance standards in the development of software

    International Nuclear Information System (INIS)

    Weisbin, A.N.

    1988-01-01

    The application of NQA-1 Quality Assurance Standards to computer software programs has been recent at the Oak Ridge National Laboratory. One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs. to characterize potential sites for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software

  12. Quality assurance feedback as a nursing management strategy.

    Science.gov (United States)

    Brannon, D; Bucher, J A

    1989-01-01

    Quality assurance and effective nurse management can be viewed as intersecting goals. Objective feedback derived from quality assurance data is a potentially powerful means of enhancing nurses' performance and job satisfaction. The use of automated information systems to provide such direct feedback offers the additional advantage of recognizing nurses as self-monitoring, self-correcting professionals. The need, opportunity, and challenge involved in meshing quality assurance with human resource management through computer-generated feedback are discussed in the context of the home health care setting.

  13. Quality Assurance Plan, N springs expedited response action

    International Nuclear Information System (INIS)

    Jackson, G.J.

    1994-01-01

    This document is the Quality Assurance Plan (QAP) to be followed during the definitive design, construction, and operational phases for activities associated with the N Springs Expedited Response Action (ERA) for the 100-NR-2 Operable Unit (OU). Westinghouse Hanford Company (WHC) will comply with the US Department of Energy (DOE) Order 5700.6C, Quality Assurance (DOE 1989), and the US Environmental Protection Agency (EPA), EPA/530-SW-86-031, Technical Guidance Document: Construction Quality Assurance for Hazardous Waste Land Disposal Facilities (EPA 1986)

  14. Hanford Tanks Initiative quality assurance implementation plan

    International Nuclear Information System (INIS)

    Huston, J.J.

    1998-01-01

    Hanford Tanks Initiative (HTI) Quality Assurance Implementation Plan for Nuclear Facilities defines the controls for the products and activities developed by HTI. Project Hanford Management Contract (PHMC) Quality Assurance Program Description (QAPD)(HNF-PRO599) is the document that defines the quality requirements for Nuclear Facilities. The QAPD provides direction for compliance to 10 CFR 830.120 Nuclear Safety Management, Quality Assurance Requirements. Hanford Tanks Initiative (HTI) is a five-year activity resulting from the technical and financial partnership of the US Department of Energy's Office of Waste Management (EM-30), and Office of Science and Technology Development (EM-50). HTI will develop and demonstrate technologies and processes for characterization and retrieval of single shell tank waste. Activities and products associated with HTI consist of engineering, construction, procurement, closure, retrieval, characterization, and safety and licensing

  15. Quality assurance in microbiology

    OpenAIRE

    Arora D

    2004-01-01

    Quality assurance (QA) is the total process whereby the quality of laboratory reports can be guaranteed. The term quality control covers that part of QA, which primarily concerns the control of errors in the performance of tests and verification of test results. All materials, equipment and procedures must be adequately controlled. Culture media must be tested for sterility and performance. Each laboratory must have standard operating procedures (SOPs). QA of pre-analytical, analytical and po...

  16. Material quality assurance risk assessment.

    Science.gov (United States)

    2013-01-01

    Over the past two decades the role of SHA has shifted from quality control (QC) of materials and : placement techniques to quality assurance (QA) and acceptance. The role of the Office of Materials : Technology (OMT) has been shifting towards assuran...

  17. Management assessments of Quality Assurance Program implementation effectiveness

    International Nuclear Information System (INIS)

    Snyder, D.A.

    1984-01-01

    This paper describes a method currently being used by UNC Nuclear Industries, Richland, Washington, to help assure the effectiveness of Quality Assurance (QA) Program implementation. Assessments are conducted annually by management in each department, and the results summarized to the president and his staff. The purpose of these assessments is to review the adequacy of the department's implementing procedures, training/instruction on implementing procedures, and procedure implementation effectiveness. The primary purpose is to assess effectiveness and take improvement action where the need is indicated. The QA organization provides only general guidance in conducting the assessments

  18. AVLIS Production Plant Preliminary Quality Assurance Plan and Assessment

    International Nuclear Information System (INIS)

    1984-01-01

    This preliminary Quality Assurance Plan and Assessment establishes the Quality Assurance requirements for the AVLIS Production Plant Project. The Quality Assurance Plan defines the management approach, organization, interfaces, and controls that will be used in order to provide adequate confidence that the AVLIS Production Plant design, procurement, construction, fabrication, installation, start-up, and operation are accomplished within established goals and objectives. The Quality Assurance Program defined in this document includes a system for assessing those elements of the project whose failure would have a significant impact on safety, environment, schedule, cost, or overall plant objectives. As elements of the project are assessed, classifications are provided to establish and assure that special actions are defined which will eliminate or reduce the probability of occurrence or control the consequences of failure. 8 figures, 18 tables

  19. Nuclear powerplant functions: quality assurance, construction

    International Nuclear Information System (INIS)

    Karpa, P.

    1984-01-01

    The author proposes that multilayer Quality Control is burdensome and ineffective. He proposes that the earlier approaches of having responsible field engineers back on the job site instead of at a home office be reinitiated to speed up necessary design changes and hold down costs. It is then the job of the quality control personnel to assure that the field engineer is doing his job. The idea of using the reactor start-up process as part of the quality assurance program is also proposed. Also discussed is the idea of Operating License Contracts or One Step Licensing Approach

  20. GLYCOHEMOGLOBIN - COMPARISON OF 12 ANALYTICAL METHODS, APPLIED TO LYOPHILIZED HEMOLYSATES BY 101 LABORATORIES IN AN EXTERNAL QUALITY ASSURANCE PROGRAM

    NARCIS (Netherlands)

    WEYKAMP, CW; PENDERS, TJ; MUSKIET, FAJ; VANDERSLIK, W

    Stable lyophilized ethylenediaminetetra-acetic acid (EDTA)-blood haemolysates were applied in an external quality assurance programme (SKZL, The Netherlands) for glycohaemoglobin assays in 101 laboratories using 12 methods. The mean intralaboratory day-to-day coefficient of variation (CV),

  1. Study on quality assurance for high-level radioactive waste disposal project (2). Quality assurance system for the site characterization phase in the Yucca Mountain Project

    International Nuclear Information System (INIS)

    Takada, Susumu

    2006-01-01

    The objective of this report is to assist related organizations in the development of quality assurance systems for a high-level radioactive waste disposal system. This report presents detail information with which related organizations can begin the development of quality assurance systems at an initial phase of repository development for a high-level radioactive waste disposal program, including data qualification, model validation, systems and facilities for quality assurance (e.g., technical data management system, sample management facility, etc.), and QA program applicability (items and activities). These descriptions are based on information in QA program for the Yucca Mountain Project (YMP), such as the U.S. Department of Energy (DOE) Quality Assurance Requirements and Description (QARD), DOE/RW-0333P, quality implementing procedures, and reports implemented by the procedures. Additionally, this report includes some brief recommendations for developing of quality assurance systems, such as establishment of quality assurance requirements, measures for establishment of QA system. (author)

  2. In-service quality assurance at the Fessenheim nuclear power plant

    International Nuclear Information System (INIS)

    Waller, A.

    1980-01-01

    Quality assurance is a combination of systematic and planned actions applied so as to give the adequate degree of confidence in the effective obtention of quality. Quality assurance is a daily requestioning resulting from systematic inspections and checks. The different principles permitting the in-service quality assurance system to be applied is presented [fr

  3. The IAEA Code of Practice on quality assurance, and quality assurance requirements and practices in Member States

    International Nuclear Information System (INIS)

    Raisic, N.

    1982-01-01

    The IAEA Code of Practice on Quality Assurance for Safety in Nuclear Power Plants and the corresponding Safety Guides are reviewed and compared with quality assurance (QA) practices in the IAEA Member States. The QA requirements stipulated by the Code place on the nuclear power plant owner the responsibility to establish an overall QA programme for the plant. In selecting the QA programme level for specific activities, the Code allows of a flexible approach but does not specify gradation in programme requirements. The Code is placing the burden of quality-achieving and quality-assuring functions on the task-performing organizations, namely the designers, manufacturers, constructors and plant operators. The plant owner provides for the management of the overall QA programme, surveillance of activities and verifications of the effectiveness of the constituent programmes of all project participants through programme audits and evaluations. The Code and the supporting Safety Guides are consistent with existing QA practices in Member States. However, certain differences exist, which are mainly expressed in the different QA functions assigned to the various organizations participating in the overall QA programme. Also, some Member States place more emphasis on redundant verification activities than on quality-achieving functions. Tendencies are also identified to grade the QA requirements in respect of items and activities, in accordance with some pre-established criteria. In an annex to the paper, QA practices in Member States participating in the Agency's Technical Review Committee on Quality Assurance (TRC-QA) are reviewed, indicating their similarities to and differences from the Code

  4. Quality Assurance Requirements and Description

    International Nuclear Information System (INIS)

    Ram Murthy

    2002-01-01

    The Quality Assurance Requirements and Description (QARD) is the principal Quality Assurance (QA) document for the Civilian Radioactive Waste Management Program (Program). It establishes the minimum requirements for the QA program [INTRODUCTION :1p2s (NOT A REQUIREMENT)]. The QARD contains regulatory requirements and program commitments necessary for the development of an effective QA program [INTRODUCTION :1p3s (NOT A REQUIREMENT)]. Implementing documents must be based on, and be consistent with the QARD. The QARD applies to the following: (1) Acceptance of spent nuclear fuel and high-level waste. (2) Transport of spent nuclear fuel and high-level waste. (3) Storage of spent nuclear fuel through receipt of storage cask certification or a facility operating license. (4) Monitored Geologic Repository, including the site characterization activities [Exploratory Studies Facility (ESF) and surface based testing], through receipt of an operating license. (5) High-level waste form development through qualification, production, and acceptance. (6) Characterization of DOE spent nuclear fuel, and conditioning through acceptance of DOE spent nuclear fuel. Section 2.0, Quality Assurance Program, defines in greater detail criteria for determining work subject to the QARD

  5. Using management information systems to enhance health care quality assurance.

    Science.gov (United States)

    Rosser, L H; Kleiner, B H

    1995-01-01

    Examines how computers and quality assurance are being used to improve the quality of health care delivery. Traditional quality assurance methods have been limited in their ability to effectively manage the high volume of data generated by the health care process. Computers on the other hand are able to handle large volumes of data as well as monitor patient care activities in both the acute care and ambulatory care settings. Discusses the use of computers to collect and analyse patient data so that changes and problems can be identified. In addition, computer models for reminding physicians to order appropriate preventive health measures for their patients are presented. Concludes that the use of computers to augment quality improvement is essential if the quality of patient care and health promotion are to be improved.

  6. 222-S laboratory quality assurance plan

    International Nuclear Information System (INIS)

    Meznarich, H.K.

    1995-01-01

    This document provides quality assurance guidelines and quality control requirements for analytical services. This document is designed on the basis of Hanford Analytical Services Quality Assurance Plan (HASQAP) technical guidelines and is used for governing 222-S and 222-SA analytical and quality control activities. The 222-S Laboratory provides analytical services to various clients including, but not limited to, waste characterization for the Tank Waste Remediation Systems (TWRS), waste characterization for regulatory waste treatment, storage, and disposal (TSD), regulatory compliance samples, radiation screening, process samples, and TPA samples. A graded approach is applied on the level of sample custody, QC, data verification, and data reporting to meet the specific needs of the client

  7. Quality assurance and independent dosimetry for an intraoperative x-ray device

    International Nuclear Information System (INIS)

    Eaton, D. J.

    2012-01-01

    Purpose: Quality assurance is an essential component of accurate and safe radiotherapy delivery, and should include measurements which are independent of manufacturer-provided calibration. However, the physical and dosimetric properties of the INTRABEAM compact mobile 50 kV x-ray source are different from conventional kilovoltage therapy units and few reports describe methods for independent checks, frequencies, or tolerances for quality assurance tests. Methods: Based on the available evidence and local experience, methods are described for determination of the key dosimetric parameters: beam quality, output, isotropy, and depth doses. Internal system checks are also described, along with measurements of long-term stability. Results: A small volume parallel plate ionization chamber in a liquid water tank is the gold standard for measurements with this unit, but solid water-equivalent materials, thermoluminescent dosimeters and radiochromic film can all be used as practical alternatives with an accuracy of 5%–10%. The main cause of measurement uncertainty is positioning of the detector in the steep dose gradient, but energy dependence should also be considered. Conclusions: A quality assurance schedule with suggested tolerances is proposed, which includes both internal tests, before each treatment and on a monthly basis, and independent tests every year or after servicing or recalibration.

  8. Quality assurance in X-ray medical diagnosis - a physicist's viewpoint

    International Nuclear Information System (INIS)

    Moores, B.M.

    1985-01-01

    The role of quality assurance in the overall framework of costs, risks and benefits in X-ray medical diagnosis is outlined. Justification for implementing quality assurance is highlighted in terms of the nature and extent of radiological practice, the levels of exposure involved and the cost of providing the service. Quality assurance is discussed in terms of (i) quantitation/assessment; (ii) administration/ management; (iii) organisation; (iv) implementation. In particular, the need to implement quality assurance cost-effectively is discussed. (author)

  9. Quality assurance for hammer forgings

    International Nuclear Information System (INIS)

    Potthast, E.

    1984-01-01

    The quality assurance program introduced by Arbed Saarstahl and laid down in a quality assurance manual is described. A particular attention is attached thereby both to quality practice proper and to a reliable flow of information amongst all the persons involved. The production and test sequence schedules of the hammer forging plant are illustrated by the example of a forged valve housing for nuclear power plants. These schedules specify not only the forging process in the individual production stages but also the workpiece contour after each working operation, the heat treatment, the furnace charging, and the inspection of finished parts. The formalization of the tests is designed both to promote the customer's trust towards the supplier and to prevent the formal operations involved from hindering further technical development. (orig.) [de

  10. Revision of Krsko NPP Quality Assurance Plan

    International Nuclear Information System (INIS)

    Biscan, R.; Fifnja, I.; Kavsek, D.

    2012-01-01

    International standards from nuclear power plant operation area are being frequently upgraded and revised in accordance with the continuous improvement philosophy. This philosophy applies also to the area of Quality Assurance, which has also undergone significant improvement since the early 1950s. Besides just nuclear industry, there are also other international quality standards that are being continuously developed and revised, bringing needs for upgrades also in the nuclear application. Since the beginning of Krsko NPP construction, the overall Quality Assurance program and its applicable procedures were in place to assure that all planned and systematic actions necessary to provide adequate confidence that an item or service will satisfy given requirements to quality, are in place. The overall requirements for quality as one of the major objectives for Krsko NPP operation are also set forth in the Updated Safety Analyses Report, the document that serves as a base for operating license. During more than 30 years of Krsko NPP operation, the quality requirements and related documents were revised and upgraded in several attempts. The latest revision 6 of QD-1, Quality Assurance Plan was issued during the year 2011. The bases for the revision were: Changes of the Slovenian regulatory requirements (ZVISJV, JV5, JV9?), Changes of Krsko NPP licensing documents (USAR section 13?), SNSA inspection requirements, Changes of international standards (IAEA, ISO?), Conclusions of first PSR, Implementation of ISO standards in Krsko NPP (ISO14001, ISO17025), Changes of plant procedures, etc. One of the most obvious changes was the enlargement of the QA Plan scope to cover interdisciplinary areas defined in the plant management program MD-1, such as Safety culture, Self-assessment, Human performance, Industrial Safety etc. The attachment of the QA Plan defining relationships between certain standards was also updated to provide matrix for better correlation of requirements of

  11. Nuclear medicine quality assurance program in Argentina

    International Nuclear Information System (INIS)

    Levi de Cabrejas, Mariana; Arashiro, Jorge G.; Giannone, Carlos A.

    1999-01-01

    A two steps program has been implemented: the first one is the quality control of the equipment and the second one the development of standard procedures for clinical studies of patients. A training program for doctors and technicians of the nuclear medicine laboratories was carried out. Workshops on instrumentation and quality assurance in nuclear medicine have been organized in several parts of the country. A joint program of the CNEA and the University of Buenos Aires has trained medical physicists. A method has been established to evaluate the capability of the laboratories to produce high quality images and to follow up the implementation of the quality control program

  12. An institutional review board-based clinical research quality assurance program.

    Science.gov (United States)

    Lad, Pramod M; Dahl, Rebecca

    2013-01-01

    Despite the acknowledged importance of quality assurance in the clinical research process, the problem of how such a program should be implemented at the level of an academic teaching hospital or a similar institution has not been addressed in the literature. Despite the fact that quality assurance is expected in programs which certify and accredit Institutional Review Boards (IRBs), very little is known about the role of the IRB in programs of clinical research quality assurance. In this article we consider the definition of clinical research quality assurance, and describe a program designed to achieve it. The key elements of such a program are education at the site level, which has both mandatory and voluntary components, and an auditing and monitoring program, which reinforces the education on quality assurance. The role of the IRB in achieving the program goals and the organizational placement of the quality assurance program within the IRB structure and function are important items of discussion.

  13. Quality Assurance for Operation of Nuclear Facilities

    International Nuclear Information System (INIS)

    Park, C. G.; Kwon, H. I.; Kim, K. H.; Oh, Y. W.; Lee, Y. G.; Ha, J. H.; Lim, N. J.

    2008-12-01

    This report describes QA activities performed within 'Quality Assurance for Nuclear facility project' and results thereof. Efforts were made to maintain and improve quality system of nuclear facilities. Varification activities whether quality system was implemented in compliance with requirements. QA department assisted KOLAS accredited testing and calibration laboratories, ISO 9001 quality system, establishment of QA programs for R and D, and carried out reviews and surveys for development of quality assurance technologies. Major items of this report are as follows : - Development and Improvement of QA Programs - QA Activities - Assessment of Effectiveness and Adequacy for QA Programs

  14. Quality assurance for packaging of radioactive and hazardous materials

    International Nuclear Information System (INIS)

    Gustafson, L.D.

    1986-01-01

    The Department of Energy (DOE) has required for many years that quality assurance programs be established and implemented for the packaging of radioactive and hazardous materials. This paper identifies various requirement principles and related actions involved in establishing effective quality assurance for packaging of radioactive and hazardous materials. A primary purpose of these quality assurance program activities is to provide assurance that the packaging and transportation of hazardous materials, which includes radioactive and fissile materials, are in conformance with appropriate governmental regulations. Applicable regulations include those issued by the Nuclear Regulatory Commission (NRC), the Department of Transportation (DOT), and the Environmental Protection Agency (EPA). DOE Order 5700.6A establishes that quality assurance requirements are to be applied in accordance with national consensus standards where suitable ones are available. In the nuclear area, ANSI/ASME NQA-1 is the preferred standard

  15. Quality assurance in nuclear power plant

    International Nuclear Information System (INIS)

    Magalhaes, M.T. de

    1981-01-01

    The factors related to the licensing procedures of a nuclear power plant (quality assurance and safety analysis) are presented and discussed. The consequences of inadequate attitudes towards these factors are shown and suggestions to assure the safety of nuclear power plants in Brazil are presented. (E.G.) [pt

  16. HANDBOOK: QUALITY ASSURANCE/QUALITY CONTROL (QA/QC) PROCEDURES FOR HAZARDOUS WASTE INCINERATION

    Science.gov (United States)

    Resource Conservation and Recovery Act regulations for hazardous waste incineration require trial burns by permit applicants. uality Assurance Project Plan (QAPjP) must accompany a trial burn plan with appropriate quality assurance/quality control procedures. uidance on the prepa...

  17. Quality Assurance in Transnational Higher Education. ENQA Workshop Report 11

    Science.gov (United States)

    Bennett, Paul; Bergan, Sjur; Cassar, Daniela; Hamilton, Marlene; Soinila, Michele; Sursock, Andree; Uvalic-Trumbic, Stamenka; Williams, Peter

    2010-01-01

    The present report is the product of an ENQA (European Association for Quality Assurance in Higher Education) Bologna Seminar "Quality Assurance in Transnational Education: from words to action" hosted by the Quality Assurance Agency (QAA, UK) in London in December, 2008. The seminar discussed the current trends in Transnational…

  18. The role of quality assurance in the nuclear industry

    International Nuclear Information System (INIS)

    1985-01-01

    The paper reports on the proceedings of a one day conference on ''the role of quality assurance in the nuclear industry'', presented by the British Nuclear Forum Working Group on Quality Assurance, 1985. The conference reviews the application and effectiveness of the British Standards in the light of experience with the AGR programme, and considers the lessons learned that will benefit future projects. Seven papers are presented at the conference, of which five deal with the AGR experience with respect to quality assurance in design and manufacture. The remaining two papers examine quality assurance in computing software and building on the AGR experience. All seven papers are selected for INIS and indexed separately. (U.K.)

  19. Quality Assurance in Higher Education: A Review of Literature

    Science.gov (United States)

    Ryan, Tricia

    2015-01-01

    This paper examines the literature surrounding quality assurance in global higher education. It provides an overview of accreditation as a mechanism to ensure quality in higher education, examines models of QA, and explores the concept of quality (including definitions of quality and quality assurance). In addition, this paper provides a review of…

  20. Development of quality assurance requirements - an international comparison

    Energy Technology Data Exchange (ETDEWEB)

    Link, M [Siemens AG, Bereich Energieerzeugung (KWU), Erlangen (Germany); Mertz, W [Siemens AG, Bereich Energieerzeugung (KWU), Offenbach am Main (Germany)

    1993-12-01

    Total quality management strategy and the worldwide introduction of the DIN/ISO 9000 (EN 29 000) series of standards have given new impetus to traditional quality assurance. The most important change must surely be seen in the holistic approach of total quality management and its strict orientation towards customer requirements and satisfaction. International codes and standards for the nuclear industry will also have to be brought into line as part of the process of harmonizing quality assurance system standards. One possible approach is simply to specify a supplementary 'delta' of nuclear-specific requirements to be appended to the broad range of conventional requirements. It is a particular feature of quality-assured procedures in Germany that product and/or component related quality requirements and quality verifications are defined in the specifications of the architect engineer so that full implementation of the requirements from the design phase through to the manufacturing phase is assured. Looking at the development of the European Pressurized Water Reactor (EPR) and the elaboration of 'Common Rules', it is to be anticipated that a major step will be made toward international harmonization of safety criteria. (orig.)

  1. Development of quality assurance requirements - an international comparison

    International Nuclear Information System (INIS)

    Link, M.; Mertz, W.

    1993-01-01

    Total quality management strategy and the worldwide introduction of the DIN/ISO 9000 (EN 29 000) series of standards have given new impetus to traditional quality assurance. The most important change must surely be seen in the holistic approach of total quality management and its strict orientation towards customer requirements and satisfaction. International codes and standards for the nuclear industry will also have to be brought into line as part of the process of harmonizing quality assurance system standards. One possible approach is simply to specify a supplementary 'delta' of nuclear-specific requirements to be appended to the broad range of conventional requirements. It is a particular feature of quality-assured procedures in Germany that product and/or component related quality requirements and quality verifications are defined in the specifications of the architect engineer so that full implementation of the requirements from the design phase through to the manufacturing phase is assured. Looking at the development of the European Pressurized Water Reactor (EPR) and the elaboration of 'Common Rules', it is to be anticipated that a major step will be made toward international harmonization of safety criteria. (orig.) [de

  2. Quality assurance or total quality management

    International Nuclear Information System (INIS)

    Eisl, W.

    1992-01-01

    The globalisation of world trade and the reduction of East West polarisation means that protected markets are disappearing. This is leading to an increase in the ferocity of competition, mainly in large industrialised regions, whereby quality, delivery time, innovation and after-sales service are gaining more and more in significance. This paper is intended to show the deep rooted changes which global competition will bring with it in terms of quality assurance. 7 figs

  3. Quality assurance and management

    International Nuclear Information System (INIS)

    Newcomb, W.E.

    1989-01-01

    This paper traces the evolution of the quality assurance program of an office of waste management development (OWTD). The program's needs and commitment are examined. The author reports on the role of program and technical managers in such a program

  4. Implementation guide for Hanford Analytical Services Quality Assurance Plan

    International Nuclear Information System (INIS)

    1994-09-01

    This implementation guide for the Hanford Analytical Services Quality Assurance Plan (HASQAP) was developed by the US Department of Energy, Richland Operations Office (RL) Waste Management Division, Analytical Services Branch. This plan formally presents RL's direction for Hanford Sitewide implementation of the HASQAP. The HASQAP establishes a uniform standard for quality requirements to meet US Department of Energy Order 5700.6C, Quality Assurance (10 CFR 830.120, ''Quality Assurance Requirements''), and is intended to satisfy the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) requirements for ''Guidance on Preparation of Laboratory Quality Assurance Plans''. The quality assurance criteria specified in the HASQAP shall serve as a baseline for implementing quality management systems for the laboratories that provide analytical services, for data requesters and users, and for oversight organizations that monitor the data-generation process. Affected organizations shall implement the HASQAP requirements that are applicable to their work scope. Full implementation of the HASQAP is scheduled to occur by August 1995. RL will work with the US Environmental Protection Agency (EPA) and Washington State Department of Ecology (Ecology) to have the HASQAP document incorporated into Appendix F of the Tri-Party Agreement by early Fiscal Year 1996

  5. Quality assurance of EDP software in practical application

    International Nuclear Information System (INIS)

    Winkler, H.

    1982-01-01

    Alongside the specific properties of the soft software, it is mainly points outside the traditional testing field which apply for the quality assurance thereof. Measures for quality assurance must in particular, start in the development. This presupposes a partial-result orientated development process of software. Due to the high qualitative demands, implements for testing and inspection are of great importance. The problems in software quality assurance are typical for a young technical field where the necessity of which is indisputed, but which has to effect on an empirical-pragmatical level still, due to insufficient scientific foundation. (orig.) [de

  6. Quality Assurance Tests of the CMS Endcap RPCs

    CERN Document Server

    Ahmed, Ijaz; Hamid Ansari, M; Irfan Asghar, M; Asghar, Sajjad; Awan, Irfan Ullah; Butt, Jamila; Hoorani, Hafeez R; Hussain, Ishtiaq; Khurshid, Taimoor; Muhammad, Saleh; Shahzad, Hassan; Aftab, Zia; Iftikhar, Mian; Khan, Mohammad Khalid; Saleh, M

    2008-01-01

    In this note, we have described the quality assurance tests performed for endcap Resistive Plate Chambers (RPCs) at two different sites, Pakistan Atomic Energy Commission (PAEC) and National Centre for Physics (NCP), in Pakistan. This paper describes various quality assurance tests both at the level of gas gaps and the chambers. The data has been obtained at different time windows during the large scale production of CMS RPCs of RE2/2 and RE2/3 type. In the quality assurance tests, we have investigated parameters like dark current, strip occupancy, cluster size and efficiency of RPCs.

  7. Mixed Waste Integrated Program Quality Assurance requirements plan

    International Nuclear Information System (INIS)

    1994-01-01

    Mixed Waste Integrated Program (MWIP) is sponsored by the US Department of Energy (DOE), Office of Technology Development, Waste Management Division. The strategic objectives of MWIP are defined in the Mixed Waste Integrated Program Strategic Plan, and expanded upon in the MWIP Program Management Plan. This MWIP Quality Assurance Requirement Plan (QARP) applies to mixed waste treatment technologies involving both hazardous and radioactive constituents. As a DOE organization, MWIP is required to develop, implement, and maintain a written Quality Assurance Program in accordance with DOE Order 4700.1 Project Management System, DOE Order 5700.6C, Quality Assurance, DOE Order 5820.2A Radioactive Waste Management, ASME NQA-1 Quality Assurance Program Requirements for Nuclear Facilities and ANSI/ASQC E4-19xx Specifications and Guidelines for Quality Systems for Environmental Data Collection and Environmental Technology Programs. The purpose of the MWIP QA program is to establish controls which address the requirements in 5700.6C, with the intent to minimize risks and potential environmental impacts; and to maximize environmental protection, health, safety, reliability, and performance in all program activities. QA program controls are established to assure that each participating organization conducts its activities in a manner consistent with risks posed by those activities

  8. Mixed Waste Integrated Program Quality Assurance requirements plan

    Energy Technology Data Exchange (ETDEWEB)

    1994-04-15

    Mixed Waste Integrated Program (MWIP) is sponsored by the US Department of Energy (DOE), Office of Technology Development, Waste Management Division. The strategic objectives of MWIP are defined in the Mixed Waste Integrated Program Strategic Plan, and expanded upon in the MWIP Program Management Plan. This MWIP Quality Assurance Requirement Plan (QARP) applies to mixed waste treatment technologies involving both hazardous and radioactive constituents. As a DOE organization, MWIP is required to develop, implement, and maintain a written Quality Assurance Program in accordance with DOE Order 4700.1 Project Management System, DOE Order 5700.6C, Quality Assurance, DOE Order 5820.2A Radioactive Waste Management, ASME NQA-1 Quality Assurance Program Requirements for Nuclear Facilities and ANSI/ASQC E4-19xx Specifications and Guidelines for Quality Systems for Environmental Data Collection and Environmental Technology Programs. The purpose of the MWIP QA program is to establish controls which address the requirements in 5700.6C, with the intent to minimize risks and potential environmental impacts; and to maximize environmental protection, health, safety, reliability, and performance in all program activities. QA program controls are established to assure that each participating organization conducts its activities in a manner consistent with risks posed by those activities.

  9. Quality assurance methods and procedures for accepting radioactive waste for final storage

    International Nuclear Information System (INIS)

    Wenger, R.

    1992-01-01

    The concept of quality assurance for the final storage of radioactive materials is presented together with the procedure, characterisation, procedural development and documentation involved. Other topics include the assessment of the material to find its suitability for final storage and the tests for transport. 4 figs., 9 refs

  10. Application of quality assurance to scientific activities at Westinghouse Hanford Company

    International Nuclear Information System (INIS)

    Delvin, W.L.; Farwick, D.G.

    1988-01-01

    The application of quality assurance to scientific activities has been an ongoing subject of review, discussion, interpretation, and evaluation within the nuclear community for the past several years. This paper provides a discussion on the natures of science and quality assurance and presents suggestions for integrating the two successfully. The paper shows how those actions were used at the Westinghouse Hanford Company to successfully apply quality assurance to experimental studies and materials testing and evaluation activities that supported a major project. An important factor in developing and implementing the quality assurance program was the close working relationship that existed between the assigned quality engineers and the scientists. The quality engineers, who had had working experience in the scientific disciplines involved, were able to bridge across from the scientists to the more traditional quality assurance personnel who had overall responsibility for the project's quality assurance program

  11. Quality assurance and organizational effectiveness in hospitals.

    OpenAIRE

    Hetherington, R W

    1982-01-01

    The purpose of this paper is to explore some aspects of a general theoretical model within which research on the organizational impacts of quality assurance programs in hospitals may be examined. Quality assurance is conceptualized as an organizational control mechanism, operating primarily through increased formalization of structures and specification of procedures. Organizational effectiveness is discussed from the perspective of the problem-solving theory of organizations, wherein effecti...

  12. Quality assurance in the nuclear test program

    International Nuclear Information System (INIS)

    Shearer, J.N.

    1979-01-01

    In February 1979 Test Program laid the ground work for a new quality assurance structure. The new approach was based on the findings and recommendations of the Ad Hoc QA Program Review panel, which are summarized in this report. The new structure places the responsibility for quality assurance in the hands of the line organizations, both in the programmatic and functional elements of the LLL matrix

  13. A pioneering application of NQA-1 quality assurance standards in the development of software

    International Nuclear Information System (INIS)

    Weisbin, A.N.

    1988-01-01

    One reason for systematically applying quality assurance to computer software is the extensive use of results from computer programs to characterize potential sited for nuclear waste repositories leading ultimately to important policy making decisions. Because data from these programs characterize the likely radioactivity profile for many hundreds of years, experimental validation is not feasible. The Sensitivity and Uncertainty Analysis Methods Development Project (SUAMDP) was developed to formulate and utilize efficient and comprehensive methods for determining sensitivities of calculated results with respect to changes in all input parameters. The computerized methodology was embodied in the Gradient Enhanced Software System (GRESS). Due to the fact that GRESS was to be used in the site characterization for waste storage, stringent NQA-1 requirements were imposed by the sponsor. A working relationship between the Oak Ridge National Laboratory (ORNL) Quality Department and the research scientists developing GRESS was essential in achieving understanding and acceptance of the quality assurance requirements as applied to the SUAMDP. The relationship resulted in the SUAMDP becoming the first software project at ORNL to develop a comprehensive NQA-1 Quality Assurance Plan; this plan now serves as a model for software quality assurance at ORNL. This paper describes the evolution of this plan and its impact on the application of quality assurance procedures to software. 2 refs

  14. The effective quality assurance for image guided device using the AMC G-Box

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chong Mi [Dept. of Radiation Oncology, Asan Medical Center, Seoul (Korea, Republic of)

    2014-12-15

    According to the rapid increase recently in image-guided radiation therapy, It is necessary to control of the image guidance system completely. In particular for the main subject to the accuracy of image guided radiation therapy device to be done essentially the quality assurance. We made efficient phantom in AMC for the management of the accurate and efficient. By setting up of five very important as a quality assurance inventory of the Image guidance system, we made (AMC G-Box) phantom for quality assurance efficient and accurate. Quality assurance list were the Iso-center align, the real measurement, the center align of four direction, the accuracy of table movement and the reproducibility of Hounsfield Unit. The rectangular phantom; acrylic with a thickness of 1 cm to 10 cm × 10 cm × 10 cm was inserted the three materials with different densities respectively for measure the CBCT HU. The phantom was to perform a check of consistency centered by creating a marker that indicates the position of the center fixed. By performing the quality assurance using the phantom of existing, comparing the resulting value to the different resulting value using the AMC G-Box, experiment was analyzed time and problems. Therapy equipment was used Varian device. It was measured twice at 1-week intervals. When implemented quality assurance of an image guidance system using AMC G-Box and a phantom existing has been completed, the quality assurance result is similar in 0.2 mm ± 0.1. In the case of the conventional method, it was 45 minutes at 30 minutes. When using AMC G-Box, it takes 20 minutes 15 minutes, and declined to 50% of the time. The consistency and accurate of image guidance system tend to decline using device. Therefore, We need to perform thoroughly on the quality assurance related. It needs to be checked daily to consistency check especially. When using the AMC G-Box, It is possible to enhance the accuracy of the patient care and equipment efficiently performing

  15. 21 CFR 892.1940 - Radiologic quality assurance instrument.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radiologic quality assurance instrument. 892.1940 Section 892.1940 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1940 Radiologic quality assurance...

  16. Quality-assurance procedures: Method 5G determination of particulate emissions from wood heaters from a dilution tunnel sampling location

    Energy Technology Data Exchange (ETDEWEB)

    Ward, T.E.; Hartman, M.W.; Olin, R.C.; Rives, G.D.

    1989-06-01

    Quality-assurance procedures are contained in this comprehensive document intended to be used as an aid for wood-heater manufacturers and testing laboratories in performing particulate matter sampling of wood heaters according to EPA protocol, Method 5G. These procedures may be used in research and development, and as an aid in auditing and certification testing. A detailed, step-by-step quality assurance guide is provided to aid in the procurement and assembly of testing apparatus, to clearly describe the procedures, and to facilitate data collection and reporting. Suggested data sheets are supplied that can be used as an aid for both recordkeeping and certification applications. Throughout the document, activity matrices are provided to serve as a summary reference. Checklists are also supplied that can be used by testing personnel. Finally, for the purposes of ensuring data quality, procedures are outlined for apparatus operation, maintenance, and traceability. These procedures combined with the detailed description of the sampling and analysis protocol will help ensure the accuracy and reliability of Method 5G emission-testing results.

  17. Quality and Quality Assurance in Ethiopian Higher Education. Critical Issues and Practical Implications.

    NARCIS (Netherlands)

    Kahsay, M.

    2012-01-01

    This book critically examines quality and quality assurance in the Ethiopian higher education context. More specifically, the main research problem that guided the study was: ‘how and under what circumstances do the public Universities in Ethiopia assure quality of their education, and what

  18. Rollout of quality assurance interventions in labor room in two districts of Bihar, India

    OpenAIRE

    Jyoti Sharma; Sutapa B Neogi; Preeti Negandhi; Monika Chauhan; Siddharth Reddy; Ghanshyam Sethy

    2016-01-01

    Background: Quality of care at the facilities during childbirth remains a major concern. Improved quality could have the greatest dividend in saving maternal and newborn lives. Objective: The objective of this study was to implement quality assurance measures in the labor rooms of select public health facilities in two districts of Bihar. Methods: The labor room quality assurance intervention was implemented in two districts, Gaya and Purnea in Bihar. Health facilities having >200 deliveries/...

  19. Development of an Instructional Quality Assurance Model in Nursing Science

    Science.gov (United States)

    Ajpru, Haruthai; Pasiphol, Shotiga; Wongwanich, Suwimon

    2011-01-01

    The purpose of this study was to develop an instructional quality assurance model in nursing science. The study was divided into 3 phases; (1) to study the information for instructional quality assurance model development (2) to develop an instructional quality assurance model in nursing science and (3) to audit and the assessment of the developed…

  20. Quality assurance during site construction

    International Nuclear Information System (INIS)

    Eymess, K.J.; Haas, R.; Wellnitz, G.

    1980-01-01

    Quality Assurance for Nuclear Power Plants under consideration of pipe assembling. Flow of Quality Requirements during: - Desing - Construction - Procurement - Prefabrication - Site. Organizational Requirements and Measurements during Erection: - Incoming Control - Material Storage - Surveillance of Tools - Weld Surveillance - Nondestructive Testing - Cleaning - Final Documentation. Qualification and Training of QA Personnel. (orig.)

  1. 12: Assuring the quality of critical software

    International Nuclear Information System (INIS)

    Jacky, J.; Kalet, I.

    1987-01-01

    The authors recommend quality assurance procedures for radiation therapy software. Software quality assurance deals with preventing, detecting and repairing programming errors. Error detection difficulties are most severe in computer-based control systems, for example therapy machine control systems, because it may be impossible for users to confirm correct operation while treatments are in progress, or to intervene if things go wrong. Software quality assurance techniques observed in other industries in which public safety is at risk are reviewed. In some of these industries software must be approved or certified before it can be used. Approval is subject to technical reviews and audits by experts other than the program authors. The main obstacles to adoption of these techniques in the radiation therapy field are costs, lack of familiarity and doubts regarding efficacy. 18 refs

  2. Review of SKB's Quality Assurance Programme

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, Tamara D.; Hicks, Timothy W. (Galson Sciences LTD, Oakham, Rutland (United Kingdom))

    2009-06-15

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried of with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. SSM has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This project includes reviews of the quality assurance (QA) procedures and instructions that have been prepared for the SR-Site assessment as well as reviews of QA implementation at the canister and buffer/backfill laboratories in Oskarshamn, Sweden. The purpose of this project is to assess SKB's quality assurance with the view of providing a good basis for subsequent quality reviews in the context of future licensing. This has been achieved by examination of a number of SKB experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. Overall, the reviewed set of QA documents and instructions do provide reasonably comprehensive coverage of quality-affecting issues relating to the SR-Site safety assessment and, if implemented correctly, will generate confidence in the reliability of the safety assessment results. The results show that the efforts involving quality assurance are increasing within the SKB programme and in general appear to be satisfactory for ongoing experiments and measurements. However, progress in development of the QA documents and instructions has been relatively recent and it may be difficult for these to be fully implemented in the short period remaining before the planned

  3. Quality assurance and control for robotic GMA welding

    International Nuclear Information System (INIS)

    Xie Max X.

    1992-01-01

    A quality assurance (QA) model has been developed. This model systematically considers the relevant activities before, during and after the welding operations with respect to quality. Efficient quality assurance requires that the functionality of the present robotic welding systems needs to be increased and that the knowledge of the personnel involved in the design and production needs to be improved. The collaboration between different departments and personnel needs also to be improved. The procedure specification aspects have been studied and a method for the determination of optimal welding parameters is presented with regards to process stability, quality requirements and productivity. A main productivity problem of robotic welding systems for small series production is due to the time spent on the specification of welding procedures. In order to improve the efficiency, expert systems technology has been studied and applied to automatically generate optimal welding procedures. An objective method for the assessment of process stability has been developed, based upon the analysis of the electrical signals of welding arcs. Furthermore, a method has been developed to monitor the process stability. It is found that it is possible to identify the causes of the disturbance of process stability and to predict the weld quality characteristics based on the analysis of the electrical signals. Though quality is formed during the welding operation, the diagnosis of the causes of quality disturbances is important for the prevention of quality problems of subsequent welds and has been discussed. To assist the operators, expert systems technology is also applied. Further work should be directed to the integration of various QA functions in the robotic arc welding system so that both quality and productivity aspects of the system ban be further improved. (au)

  4. How does one develop the right quality assurance program for waste management projects?

    International Nuclear Information System (INIS)

    Hedges, D.

    1988-01-01

    The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied to regulations and guidance documents to radioactive and hazardous waste programs. The wording of the Nuclear Regulatory Commission (NRC) quality assurance (QA) requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects providing one understands and uses the intent of the requirements. This paper describes the intent of existing QA requirements as they apply to radioactive and hazardous waste programs. Methods of ensuring that the quality assurance program design will be acceptable to DOE and regulatory agencies are illustrated

  5. How does one develop the right quality assurance program for waste management projects?

    International Nuclear Information System (INIS)

    Hedges, D.

    1988-01-01

    The quality assurance requirements in use today for radioactive waste facilities, geologic repositories and hazardous waste projects were developed initially for the nuclear power plant industry, and their intent is being applied by regulations and guidance documents to radioactive and hazardous waste programs. The wording of the NRC quality assurance requirements in Appendix B of 10CFR50, the related guidance documents and the industry's ANSI/ASME NQA-1 were developed over a period of several years to address quality assurance for the design and construction of the complex and interactive systems to produce electrical power using nuclear fuel. Now, those same documents are the basis for the quality assurance requirements and guidance for waste management facilities and repositories. The intent of Appendix B of 10CFR50 and NQA-1 can easily be applied to waste projects, providing one understands and uses the intent of the requirements. This paper describes the intent of existing QA requirements as they apply to radioactive and hazardous waste programs. Methods of ensuring that the quality assurance program design will be acceptable to DOE and regulatory agencies are illustrated

  6. Quality Assurance Tracking System - R7 (QATS-R7)

    Data.gov (United States)

    U.S. Environmental Protection Agency — This is metadata documentation for the Quality Assurance Tracking System - R7, an EPA Region 7 resource that tracks information on quality assurance reviews. Also...

  7. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fishler, B

    2011-03-18

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  8. NIF Projects Controls and Information Systems Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Fishler, B.

    2011-01-01

    Quality achievement for the National Ignition Facility (NIF) and the National Ignition Campaign (NIC) is the responsibility of the NIF Projects line organization as described in the NIF and Photon Science Directorate Quality Assurance Plan (NIF QA Plan). This Software Quality Assurance Plan (SQAP) is subordinate to the NIF QA Plan and establishes quality assurance (QA) activities for the software subsystems within Controls and Information Systems (CIS). This SQAP implements an activity level software quality assurance plan for NIF Projects as required by the LLNL Institutional Software Quality Assurance Program (ISQAP). Planned QA activities help achieve, assess, and maintain appropriate quality of software developed and/or acquired for control systems, shot data systems, laser performance modeling systems, business applications, industrial control and safety systems, and information technology systems. The objective of this SQAP is to ensure that appropriate controls are developed and implemented for management planning, work execution, and quality assessment of the CIS organization's software activities. The CIS line organization places special QA emphasis on rigorous configuration control, change management, testing, and issue tracking to help achieve its quality goals.

  9. Field methods and quality-assurance plan for water-quality activities and water-level measurements, U.S. Geological Survey, Idaho National Laboratory, Idaho

    Science.gov (United States)

    Bartholomay, Roy C.; Maimer, Neil V.; Wehnke, Amy J.

    2014-01-01

    Water-quality activities and water-level measurements by the personnel of the U.S. Geological Survey (USGS) Idaho National Laboratory (INL) Project Office coincide with the USGS mission of appraising the quantity and quality of the Nation’s water resources. The activities are carried out in cooperation with the U.S. Department of Energy (DOE) Idaho Operations Office. Results of the water-quality and hydraulic head investigations are presented in various USGS publications or in refereed scientific journals and the data are stored in the National Water Information System (NWIS) database. The results of the studies are used by researchers, regulatory and managerial agencies, and interested civic groups. In the broadest sense, quality assurance refers to doing the job right the first time. It includes the functions of planning for products, review and acceptance of the products, and an audit designed to evaluate the system that produces the products. Quality control and quality assurance differ in that quality control ensures that things are done correctly given the “state-of-the-art” technology, and quality assurance ensures that quality control is maintained within specified limits.

  10. Code on the safety of nuclear power plants: Quality assurance

    International Nuclear Information System (INIS)

    1988-01-01

    This revised Code provides the principles and objectives for the establishment and implementation of quality assurance programmes applied to both the overall and each of the constituent activities associated with a nuclear power plant project. The quality assurance principles enumerated in the present Code can be usefully applied to nuclear facilities other than nuclear power plants. The quality assurance programme encompasses: (1) the activities that are necessary to achieve the appropriate quality of the respective item or service; and (2) the activities that are necessary for verifying that the required quality is achieved and that objective evidence is produced to that effect. Quality assurance is an essential aspect of good management and the quality assurance programme is the main management tool for a disciplined approach to all activities affecting quality, including, where appropriate, verification that each task has been satisfactorily performed and that necessary corrective actions have been implemented. The principles and objectives provided by the Code are applicable by all those responsible for the nuclear power plant, by plant designers, suppliers, architect-engineers, plant constructors, plant operators and other organizations participating in activities affecting quality. The Code is a revision of the previous Code of Practice (1978) on the same subject of interest to regulatory bodies and experts in quality assurance for design, siting and operation of nuclear power plants. Contents: Definitions; 1. Introduction; 2. Quality assurance programmes; 3. Organization; 4. Document control; 5. Design control; 6. Procurement control; 7. Control of items; 8. Process control; 9. Inspection and test control; 10. Non-conformance control; 11. Corrective actions; 12, Records; 13. Audits

  11. The quality assurance practice in Spain

    International Nuclear Information System (INIS)

    Mugica, A.P.

    1980-01-01

    Even when the basic requirements for a Quality Assurance Program are delineated in documents such as the Code of Federal Regulations or Standards like ANSI N 45. 2, the way in which these requirements are put into practice is very dependent on the organization to which they are applied. So, in order to approach accurately the Quality Assurance practice and experience in Spain, the legal and industrial scenario must be considered. We are trying to present an outlook of the Spanish Energy Plan, Regulations and Nuclear Industry. (orig.)

  12. Quality Assurance Source Requirements Traceability Database

    International Nuclear Information System (INIS)

    MURTHY, R.; NAYDENOVA, A.; DEKLEVER, R.; BOONE, A.

    2006-01-01

    At the Yucca Mountain Project the Project Requirements Processing System assists in the management of relationships between regulatory and national/industry standards source criteria, and Quality Assurance Requirements and Description document (DOE/R W-0333P) requirements to create compliance matrices representing respective relationships. The matrices are submitted to the U.S. Nuclear Regulatory Commission to assist in the commission's review, interpretation, and concurrence with the Yucca Mountain Project QA program document. The tool is highly customized to meet the needs of the Office of Civilian Radioactive Waste Management Office of Quality Assurance

  13. Nuclear quality assurance: indoctrination and training

    International Nuclear Information System (INIS)

    Sternberg, A.

    1977-01-01

    Quality Assurance is defined as ''all the planned and systematic actions necessary to provide adequate confidence that a structure, system or component will perform satisfactorily in service''. Within Public Service Electric and Gas Company (PSEandG) Quality Assurance, a discipline which involves everyone within the company, is considered. In order to economically and effectively communicate this discipline throughout the concerned areas of the Company so that involved personnel are made fully aware of the complete scope of their tasks, a detailed comprehensive indoctrination and training program has been developed and implemented. 3 refs

  14. Quality Assurance of Assessment and Moderation Discourses Involving Sessional Staff

    Science.gov (United States)

    Grainger, Peter; Adie, Lenore; Weir, Katie

    2016-01-01

    Quality assurance is a major agenda in tertiary education. The casualisation of academic work, especially in teaching, is also a quality assurance issue. Casual or sessional staff members teach and assess more than 50% of all university courses in Australia, and yet the research in relation to the role sessional staff play in quality assurance of…

  15. Operational excellence (six sigma) philosophy: Application to software quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Lackner, M.

    1997-11-01

    This report contains viewgraphs on operational excellence philosophy of six sigma applied to software quality assurance. This report outlines the following: goal of six sigma; six sigma tools; manufacturing vs administrative processes; Software quality assurance document inspections; map software quality assurance requirements document; failure mode effects analysis for requirements document; measuring the right response variables; and questions.

  16. Quality assurance in production and use of special form radioactive material - focal points in BAM approvals

    International Nuclear Information System (INIS)

    Rolle, A.; Buhlemann, L.

    2004-01-01

    BAM as the competent authority for approval of special form radioactive material attaches great importance to a detailed audit of the required quality assurance programs for design, manufacture, testing, documentation, use, maintenance and inspection. Applicants have to submit, together with application documentation information on general arrangements for quality assurance, as well as on quality assurance in production and in operation. Fields where BAM has often found deficiencies are leak test methods, weld seam quality and the safety level after use

  17. On-site quality assurance during erection of a nuclear power plant

    International Nuclear Information System (INIS)

    Mueller, J.

    1976-01-01

    The paper deals with general quality assurance measures, the quality assurance during on-site production (incoming inspection, inspection of welds and welding equipment) and describes in more detail the quality assurance procedures for the containment. (RW) [de

  18. Helical Tomotherapy Quality Assurance

    International Nuclear Information System (INIS)

    Balog, John; Soisson, Emilie

    2008-01-01

    Helical tomotherapy uses a dynamic delivery in which the gantry, treatment couch, and multileaf collimator leaves are all in motion during treatment. This results in highly conformal radiotherapy, but the complexity of the delivery is partially hidden from the end-user because of the extensive integration and automation of the tomotherapy control systems. This presents a challenge to the medical physicist who is expected to be both a system user and an expert, capable of verifying relevant aspects of treatment delivery. A related issue is that a clinical tomotherapy planning system arrives at a customer's site already commissioned by the manufacturer, not by the clinical physicist. The clinical physicist and the manufacturer's representative verify the commissioning at the customer site before acceptance. Theoretically, treatment could begin immediately after acceptance. However, the clinical physicist is responsible for the safe and proper use of the machine. In addition, the therapists and radiation oncologists need to understand the important machine characteristics before treatment can proceed. Typically, treatment begins about 2 weeks after acceptance. This report presents an overview of the tomotherapy system. Helical tomotherapy has unique dosimetry characteristics, and some of those features are emphasized. The integrated treatment planning, delivery, and patient-plan quality assurance process is described. A quality assurance protocol is proposed, with an emphasis on what a clinical medical physicist could and should check. Additionally, aspects of a tomotherapy quality assurance program that could be checked automatically and remotely because of its inherent imaging system and integrated database are discussed

  19. Westinghouse Water Reactor Divisions quality assurance plan

    International Nuclear Information System (INIS)

    1977-09-01

    The Quality Assurance Program used by Westinghouse Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements. This program satisfies the NRC Quality Assurance Criteria, 10CFR50 Appendix B, to the extent that these criteria apply to safety related NSSS equipment. Also, it follows the regulatory position provided in NRC regulatory guides and the requirements of ANSI Standard N45.2.12 as identified in this Topical Report

  20. Quality assurance of nursing web sites: development and implications of the ALEU method.

    Science.gov (United States)

    Cambil-Martín, Jacobo; Flynn, Maria; Villaverde-Gutiérrez, Carmen

    2011-09-01

    This article presents a study that evaluated the physical accessibility, readability, and usability of Spanish nursing Web sites and discusses the quality assurance issues raised, which are relevant to the wider nursing community. The Internet is recognized as an important source of health information for both nurses and the general public. Although it makes health-related information universally available, the wide variation in the overall quality of health Web sites is problematic. This raises many questions for the nursing profession: about what constitutes a good-quality Web site, about the nature of the information that nurses are finding and using to support their professional education, research, and clinical practice, and about the impact that Internet information ultimately has on health interactions and nursing care. The process of completing this small study showed that it is possible to usefully assess dimensions of Web site quality and suggested that it may be feasible to develop tools to help nurses evaluate national and international nursing Web sites. More research is needed to understand how nurses use the Internet to support their everyday professional practices, but the development and application of international Web site quality assurance tools may be important for maintaining professional nursing standards in the Internet age.

  1. Analytical Quality by Design in pharmaceutical quality assurance: Development of a capillary electrophoresis method for the analysis of zolmitriptan and its impurities.

    Science.gov (United States)

    Orlandini, Serena; Pasquini, Benedetta; Caprini, Claudia; Del Bubba, Massimo; Pinzauti, Sergio; Furlanetto, Sandra

    2015-11-01

    A fast and selective CE method for the determination of zolmitriptan (ZOL) and its five potential impurities has been developed applying the analytical Quality by Design principles. Voltage, temperature, buffer concentration, and pH were investigated as critical process parameters that can influence the critical quality attributes, represented by critical resolution values between peak pairs, analysis time, and peak efficiency of ZOL-dimer. A symmetric screening matrix was employed for investigating the knowledge space, and a Box-Behnken design was used to evaluate the main, interaction, and quadratic effects of the critical process parameters on the critical quality attributes. Contour plots were drawn highlighting important interactions between buffer concentration and pH, and the gained information was merged into the sweet spot plots. Design space (DS) was established by the combined use of response surface methodology and Monte Carlo simulations, introducing a probability concept and thus allowing the quality of the analytical performances to be assured in a defined domain. The working conditions (with the interval defining the DS) were as follows: BGE, 138 mM (115-150 mM) phosphate buffer pH 2.74 (2.54-2.94); temperature, 25°C (24-25°C); voltage, 30 kV. A control strategy was planned based on method robustness and system suitability criteria. The main advantages of applying the Quality by Design concept consisted of a great increase of knowledge of the analytical system, obtained throughout multivariate techniques, and of the achievement of analytical assurance of quality, derived by probability-based definition of DS. The developed method was finally validated and applied to the analysis of ZOL tablets. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Reasoning-Supported Quality Assurance for Knowledge Bases

    OpenAIRE

    Nikitina, Nadeschda

    2012-01-01

    The increasing application of ontology reuse and automated knowledge acquisition tools in ontology engineering brings about a shift of development efforts from knowledge modeling towards quality assurance. Despite the high practical importance, there has been a substantial lack of support for ensuring semantic accuracy and conciseness. In this thesis, we make a significant step forward in ontology engineering by developing a support for two such essential quality assurance activities.

  3. Linear accelerator quality assurance using EPIQA software

    International Nuclear Information System (INIS)

    Bozhikov, S.; Sokerov, H.; Tonev, A.; Ivanova, K.

    2012-01-01

    Unlike treatment with static fields, using a dynamic multileaf collimator (dMLC), there are significant dosimetric issues which must be assessed before dynamic therapy can be implemented. The advanced techniques require some additional commissioning and quality assurance tests. The results of standard quality assurance (QA) machine tests and commissioning tests for volume modulated arc therapy (VMAT) using electronic portal image device (EPID) and 'EPIQA' software are presented. (authors)

  4. Application of quality assurance program to safety related aging equipment or components

    International Nuclear Information System (INIS)

    Papaiya, N.C.

    1990-01-01

    This paper addresses how quality assurance programs and their criteria are applied to safety related and aging equipment or components used in commercial nuclear plant applications. The QA Programs referred to are 10CFR50 Appendix B and EPRI NP-5652. The QA programs as applicable are applied to equipment/component aging qualification, preventive maintenance, surveillance testing and procurement engineering. The intent of this paper is not the technical issues, methods and research of aging. The paper addresses QA program's application to age-related equipment or components in safety related applications. Quality Assurance Program 10CFR50 Appendix B applies to all safety related aging components or equipment related to the qualification program and associated preventive maintenance and surveillance testing programs. Quality Assurance involvement with procurement engineering for age-related commercial grade items supports EPRI NP-5652 and assures that the dedicated OGI is equal to the item purchased as a basic component to 10CFR50 Appendix B requirements

  5. 10 CFR 71.103 - Quality assurance organization.

    Science.gov (United States)

    2010-01-01

    ... location or locations where activities are performed, the organizational structure for executing the... the organizational structure, the individual(s) assigned the responsibility for assuring effective... performing quality assurance functions must have sufficient authority and organizational freedom to— (1...

  6. Regulatory inspection of the implementation of quality assurance programmes

    International Nuclear Information System (INIS)

    1989-01-01

    This Manual provides guidance to Member States in the organization and performance of their regulatory inspection functions regarding the implementation of nuclear power plant quality assurance programmes. It addresses the interface between, and is consistent with, the IAEA Nuclear Safety Standards (NUSS programme) documents on quality assurance and governmental organization. The Manual offers a practical model and examples for performing regulatory inspections to ensure that the quality assurance programme is operating satisfactorily in the siting, design, manufacturing, construction, commissioning, operation and decommissioning of nuclear power plants. The primary objective is to confirm that the licensee has the capability to manage and control the effective performance of all quality assurance responsibilities during all phases of a nuclear power project. The guidance provided through this Manual for proper establishment and execution of the regulatory inspections helps to enforce the effective implementation of the quality assurance programme as a management control system that the nuclear industry should establish and use in attaining the safety and reliability objectives for nuclear installations. This enforcement action by national regulatory bodies and the emphasis on the purposes and advantages of quality assurance as an important management tool integrated within the total project task have been recommended by the IAEA International Nuclear Safety Advisory Group (INSAG). The primary intended users of this Manual are the management personnel and high level staff from regulatory bodies but it will also be helpful to management personnel from nuclear utilities and vendors. They all are inevitable partners in a nuclear power project and this document offers all of them valuable information on the better accomplishment of quality assurance activities to ensure the common objective of safe and reliable nuclear power production

  7. Repository construction management and quality assurance

    International Nuclear Information System (INIS)

    Hood, F.C.

    1984-01-01

    An emphasis on preventive rather than reactive management is key to an efficient construction management operation. Development of contingency plans to deal with unexpected adverse conditions, e.g., brine pockets during mining operations, are an integral part of the management program to ensure project safety, quality, cost, schedule and environmental objectives are met. A viable quality assurance program with active management support will optimize management effectiveness in reaching project goals. With adequate planning and perceptive application of the proper management controls, Quality Assurance becomes an essential ingredient for efficiently managing a job because it has been built into the management system rather than being an uninvolved peripheral entity. 6 references, 3 figures

  8. Quality assurance and quality control for Hydro-Quebec's ambient air monitoring networks

    International Nuclear Information System (INIS)

    Lambert, M.; Varfalvy, L.

    1993-01-01

    Hydro Quebec has three ambient air monitoring networks to determine the contribution of some of its thermal plants to ambient air quality. They are located in Becancour (gas turbines), Iles-de-la-Madeleine (diesel), and Tracy (conventional oil-fired). To ensure good quality results and consistency between networks, a quality assurance/quality control program was set up. A description is presented of the ambient air quality monitoring network and the quality assurance/quality control program. A guide has been created for use by the network operators, discussing objectives of the individual network, a complete description of each network, field operation for each model of instrument in use, treatment of data for each data logger in use, global considerations regarding quality assurance and control, and reports. A brief overview is presented of the guide's purpose and contents, focusing on the field operation section and the sulfur dioxide and nitrogen oxide monitors. 6 figs., 1 tab

  9. Quality Assurance Standards for Symptomatic Breast Disease Services

    OpenAIRE

    Department of Health (Ireland)

    2007-01-01

    Quality Assurance Standards for Symptomatic Breast Disease Services People in Ireland have a right to expect that medical care be of good quality. They expect that standards of care are consistently high. They expect that access to care is easy, speedy, effective and efficient. Society expects quality of care to measure up to international norms of good practice. Such assurance can be given by auditing the quality of activity. Click here to download PDF 606kb

  10. QANU - Quality Assurance Netherlands Universities

    DEFF Research Database (Denmark)

    Jensen, Henrik Toft; Maria E., Weber; Vyt, André

    The Quality Assurance Netherlands Universities (QANU) underwent an ENQA-coordinated external review in 2016. The review was chaired by Henrik Toft Jensen, Research fellow at Roskilde University (RUC), Denmark....

  11. [Quality assurance in head and neck medical oncology].

    Science.gov (United States)

    Digue, Laurence; Pedeboscq, Stéphane

    2014-05-01

    In medical oncology, how can we be sure that the right drug is being administered to the right patient at the right time? The implementation of quality assurance criteria is important in medical oncology, in order to ensure that the patient receives the best treatment safely. There is very little literature about quality assurance in medical oncology, as opposed to radiotherapy or cancer surgery. Quality assurance must cover the entire patient care process, from the diagnosis, to the therapeutic decision and drug distribution, including its selection, its preparation and its delivery to the patient (administration and dosage), and finally the potential side effects and their management. The dose-intensity respect is crucial, and its reduction can negatively affect overall survival rates, as shown in breast and testis cancers for example. In head and neck medical oncology, it is essential to respect the few well-standardized recommendations and the dose-intensity, in a population with numerous comorbidities. We will first review quality assurance criteria for the general medical oncology organization and then focus on head and neck medical oncology. We will then describe administration specificities of head and neck treatments (chemoradiation, radiation plus cetuximab, postoperative chemoradiation, induction and palliative chemotherapy) as well as their follow-up. Lastly, we will offer some recommendations to improve quality assurance in head and neck medical oncology.

  12. The Groundwater Performance Assessment Project Quality Assurance Plan

    International Nuclear Information System (INIS)

    Luttrell, Stuart P.

    2006-01-01

    U.S. Department of Energy (DOE) has monitored groundwater on the Hanford Site since the 1940s to help determine what chemical and radiological contaminants have made their way into the groundwater. As regulatory requirements for monitoring increased in the 1980s, there began to be some overlap between various programs. DOE established the Groundwater Performance Assessment Project (groundwater project) in 1996 to ensure protection of the public and the environment while improving the efficiency of monitoring activities. The groundwater project is designed to support all groundwater monitoring needs at the site, eliminate redundant sampling and analysis, and establish a cost-effective hierarchy for groundwater monitoring activities. This document provides the quality assurance guidelines that will be followed by the groundwater project. This QA Plan is based on the QA requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--General Provisions/Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory's Standards-Based Management System. In addition, the groundwater project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The groundwater project has determined that the Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan

  13. Quality assurance manual for the development of digital systems

    International Nuclear Information System (INIS)

    Lee, Cheol Kwon; Kwon, Kee Choon; You, Young Eun; Kim, Kwan Hyun; Park, Jung Woo; Park, Chan Seok

    2001-12-01

    A digital safety system is being developed by three companies under the Korea Nuclear I and C System R and D Program. This Quality Assurance Manual (QAM) is written to ensure the safety and reliability of the system and to meet the regulatory requirements associated with quality assurance. This QAM describes eighteen elements of quality assurance criteria required for the development of the system, which are coincident with the criteria specified in Nuclear Energy Laws and Enforcement Regulations of Nuclear Energy Laws and 10CFR50 Appendix B. This QAM is submitted to the regulatory body with other documents related to the quality assurance activities performed during the system development. And its safety, validity and fulfillment are reviewed and audited in the review process of topical report of the digital safety system

  14. QUALITY ASSURANCE SYSTEMS IN POLISH AND UKRAINIAN HIGHER EDUCATION. A COMPARATIVE ANALYSIS

    Directory of Open Access Journals (Sweden)

    Marta Tutko

    2015-02-01

    Full Text Available The article deals with the progress made to develop external and internal quality assurance systems in Polish and Ukrainian higher education in the European Higher Education Area background. The focus of the paper is on the extent to which quality assurance systems in these countries are following the Standards and Guidelines for Quality Assurance in the European Higher Education Area. Furthermore, internal and external quality assur-ance in the European context is presented in the article. The authors of the article also conducted a comparative analysis of quality assurance systems in Polish and Ukrainian higher education.

  15. A quality assurance programme for reload fuel for light-water reactors

    International Nuclear Information System (INIS)

    Nilson, R.

    1976-01-01

    The Exxon Nuclear quality assurance programme for the design and fabrication of reload fuel for light-water reactors is described. The programme is based on the 18 quality assurance criteria used for the design and construction of nuclear facilities in the United States of America, but is broadened considerably to reflect other inputs and experiences unique to nuclear fuel production. The government and utility interfaces with the fuel supplier in the area of quality assurance, and future trends, for example, the development of topical quality assurance reports, are also discussed. Quality assurance is discussed in terms of three fundamental categories: management control, engineering assurance and quality control. Examples of specific design, processing and inspection considerations which relate to known fuel failure mechanisms are discussed. The results of irradiated fuel examinations to date have shown that certain fuel failure mechanisms can be alleviated by the considerations described and that fuel of the requisite quality can be consistently produced. (author)

  16. Quality assurance services

    International Nuclear Information System (INIS)

    For over 20 years the quality assurance services at the Springfields Laboratories have been concerned with manufacturing both simple and complex engineering products to the highest standard. The scientists working there have considerable expertise in the practical application of quality control and the development and design of inspection and non-destructive testing equipment. The folder contains six sheets or leaflets illustrating the work and equipment. The subjects are the mechanical standards laboratory, non-destructive testing, the digitising table, the peripheral camera, automated measurement, data handling and presentation, and the computer controlled three axis co-ordinate measuring machine. (U.K.)

  17. 40 CFR 75.59 - Certification, quality assurance, and quality control record provisions.

    Science.gov (United States)

    2010-07-01

    ... specified in Equation A-9 in appendix A to this part; (D) Statistical “t” value used in calculations; (E... monitoring systems, the coefficient or “K” factor or other mathematical algorithm used to adjust the... application, or periodically if a different method is used for annual quality assurance testing). (2) For each...

  18. Quality assurance in siting of Nuclear Power Plants

    International Nuclear Information System (INIS)

    2005-03-01

    This guide describes the requirements of quality assurance programme (QAP) that need to be implemented at the siting stage, by the organisation having overall responsibility for the nuclear power plant. The scope of the guide covers the quality assurance aspects related to management, performance and assessment activities during siting stage of NPPs

  19. Quality assurance in nuclear fuel element component supply

    International Nuclear Information System (INIS)

    Jenkins, B.P.

    1987-01-01

    The paper describes the application of Quality Assurance to nuclear fuel element component supply. The Quality Assurance programme includes integrated procurement, purchasing, surveillance and receipt inspection functions. Purchasing policy is based on a consistent preference for competitive tendering. Multiple sourcing is used to encourage competitive pricing and increase security of supply. A receipt inspection facility is maintained to ensure the high product quality levels demanded by the nuclear industry. (U.K.)

  20. Quality Assurance in Higher Education: Reflection, Criticism, and Change

    Science.gov (United States)

    Yingqiang, Zhang; Yongjian, Su

    2016-01-01

    Quality assurance in modern higher education is both an accountability-oriented ideology and a technological method. It has also evolved into a increasingly rationalist and professionalized power mechanism. Its advocacy of compliance, technological mythology, and imbalance between power and responsibility are inherent disadvantages of higher…

  1. [Extraction of management information from the national quality assurance program].

    Science.gov (United States)

    Stausberg, Jürgen; Bartels, Claus; Bobrowski, Christoph

    2007-07-15

    Starting with clinically motivated projects, the national quality assurance program has established a legislative obligatory framework. Annual feedback of results is an important means of quality control. The annual reports cover quality-related information with high granularity. A synopsis for corporate management is missing, however. Therefore, the results of the University Clinics in Greifswald, Germany, have been analyzed and aggregated to support hospital management. Strengths were identified by the ranking of results within the state for each quality indicator, weaknesses by the comparison with national reference values. The assessment was aggregated per clinical discipline and per category (indication, process, and outcome). A composition of quality indicators was claimed multiple times. A coherent concept is still missing. The method presented establishes a plausible summary of strengths and weaknesses of a hospital from the point of view of the national quality assurance program. Nevertheless, further adaptation of the program is needed to better assist corporate management.

  2. Quality assurance activities and proposals at the international level

    International Nuclear Information System (INIS)

    Davison, M.

    1985-01-01

    A number of international bodies have attempted to stimulate wider interest in Quality Assurance in X-ray departments. A major initiative has been taken by WHO with the publication of its recommendations in 1982 under the title Quality Assurance in Diagnostic Radiology, in which they indicated the action that should be taken at various national, professional and local levels. The recommendations of ICRP in Publication 26 point to the need for quality assurance programmes that will obtain optimum diagnostic information at minimum cost and minimum patient dose. ICRU have been considering the need for cost-effective quality assurance programmes and the specification of standards for image quality. The IEC and various manufacturers' organisations have begun to consider the part they can play in setting up quality control procedures. The most active group has been the ISRRT, which has arranged a series of seminars and workshops for radiographers in various parts of the world. Future needs for international support lie in the provision of training programmes, the publication of comparative statistical data and the development of image quality standards. (author)

  3. Implementation of benchmark management in quality assurance audit activities

    International Nuclear Information System (INIS)

    Liu Yongmei

    2008-01-01

    The concept of Benchmark Management is that the practices of the best competitor are taken as benchmark, to analyze and study the distance between that competitor and the institute, and take efficient actions to catch up and even exceed the competitor. This paper analyzes and rebuilds all the process for quality assurance audit with the concept of Benchmark Management, based on the practices during many years of quality assurance audits, in order to improve the level and effect of quality assurance audit activities. (author)

  4. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    Energy Technology Data Exchange (ETDEWEB)

    Heaton, H.T. II; Taylor, A.R. Jr. [Center for Devices and Radiological Health, Rockville, MD (United States)

    1993-12-31

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. This paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory.

  5. Development of a quality assurance program for ionizing radiation secondary calibration laboratories

    International Nuclear Information System (INIS)

    Heaton, H.T. II; Taylor, A.R. Jr.

    1993-01-01

    For calibration laboratories, routine calibrations of instruments meeting stated accuracy goals are important. One method of achieving the accuracy goals is to establish and follow a quality assurance program designed to monitor all aspects of the calibration program and to provide the appropriate feedback mechanism if adjustments are needed. In the United States there are a number of organizations with laboratory accreditation programs. All existing accreditation programs require that the laboratory implement a quality assurance program with essentially the same elements in all of these programs. Collectively, these elements have been designated as a Measurement Quality Assurance (MQA) program. This paper will briefly discuss the interrelationship of the elements of an MQA program. Using the Center for Devices and Radiological Health (CDRH) X-ray Calibration Laboratory (XCL) as an example, it will focus on setting up a quality control program for the equipment in a Secondary Calibration Laboratory

  6. Environmental Restoration Remedial Action quality assurance requirements document

    International Nuclear Information System (INIS)

    1991-01-01

    This document defines the quality assurance requirements for the US Department of Energy-Richland Operations Office Environmental Restoration Remedial Action program at the Hanford Site. The Environmental Restoration Remedial Action program implements significant commitments made by the US Department of Energy in the Hanford Federal Facility Agreement and Consent Order entered into with the Washington State Department of Ecology and the US Environmental Protection Agency. This document combines quality assurance requirements from various source documents into one set of requirements for use by the US Department of Energy-Richland Operations Office and other Environmental Restoration Remedial Action program participants. This document will serve as the basis for developing Quality Assurance Program Plans and implementing procedures by the participants. The requirements of this document will be applied to activities affecting quality, using a graded approach based on the importance of the item, service, or activity to the program objectives. The Quality Assurance Program that will be established using this document as the basis, together with other program and technical documents, form an integrated management control system for conducting the Environmental Restoration Remedial Action program activities in a manner that provides safety and protects the environment and public health

  7. Internal Quality Assurance Benchmarking. ENQA Workshop Report 20

    Science.gov (United States)

    Blackstock, Douglas; Burquel, Nadine; Comet, Nuria; Kajaste, Matti; dos Santos, Sergio Machado; Marcos, Sandra; Moser, Marion; Ponds, Henri; Scheuthle, Harald; Sixto, Luis Carlos Velon

    2012-01-01

    The Internal Quality Assurance group of ENQA (IQA Group) has been organising a yearly seminar for its members since 2007. The main objective is to share experiences concerning the internal quality assurance of work processes in the participating agencies. The overarching theme of the 2011 seminar was how to use benchmarking as a tool for…

  8. Quality assurance program plan for SNF characterization support project

    International Nuclear Information System (INIS)

    Tanke, J.M.

    1997-01-01

    This Quality Assurance Program Plan (QAPP) provides information on how the Quality Assurance Program is implemented for the Spent Nuclear Fuel Characterization Support Project. This QAPP has been developed specifically for the Spent Nuclear Fuel Characterization Support Project, per Letter of Instruction (LOI) from Duke Engineering and Services Company, letter No. DESH-9655870, dated Nov. 22, 1996. It applies to those items and tasks which affect the completion of activities identified in the work breakdown structure of the Project Management Plan (PMP) and LOI. These activities include installation of sectioning equipment and furnace, surface and subsurface examinations, sectioning for metallography, and element drying and conditioning testing, as well as project related operations within the 327 facility as it relates to the specific activities of this project. General facility activities are covered in other appropriate QA-PPS. In addition, this QAPP supports the related quality assurance activities addressed in CM-2-14, Hazardous Material Packaging and Shipping,1261 and HSRCM-1, Hanford Site Radiological Control Manual. The 327 Building is currently transitioning from being a Pacific Northwest National Laboratory (PNNL) managed facility to a Babcock and Wilcox Hanford Company (BVMC) managed facility. During this transition process existing procedures and documents will be utilized until replaced by BVMC procedures and documents. These documents conform to the requirements found in PNL-MA-70, Quality Assurance Manual and PNL-MA-8 1, Hazardous Materials Shipping Manual. The Quality Assurance Program Index (QAPI) contained in Table 1 provides a matrix which shows how project activities relate to IO CFR 830.120 and 5700.6C criteria. Quality Assurance program requirements will be addressed separate from the requirements specified in this document. Other Hanford Site organizations/companies may be utilized in support of this project and the subject organizations are

  9. Hanford Waste Vitrification Plant quality assurance program description: Overview and applications

    International Nuclear Information System (INIS)

    Caplinger, W.H.

    1990-12-01

    This document describes the Hanford Waste Vitrification Plant Project Quality Assurance Program. This program is being implemented to ensure the acceptability of high-level radioactive canistered waste forms produced by the Hanford Waste Vitrification Plant for disposal in a licensed federal repository. The Hanford Waste Vitrification Plant Quality Assurance Program is comprised of this Quality Assurance Program Description as well as the associated contractors' quality assurance programs. The objective of this Quality Assurance Program Description is to provide the Hanford Waste Vitrification Plant Project participants with guidance and direction for program implementation while satisfying the US Department of Energy Office of Civilian Radioactive Waste Management needs in repository licensing activities with regard to canistered waste forms. To accomplish this objective, this description will be prepared in three parts: Part 1 - Overview and applications document; Part 2 - Development and qualification of the canistered waste form; Part 3 - Production of canistered waste forms. Part 1 describes the background, strategy, application, and content of the Hanford Waste Vitrification Plant Quality Assurance Program. This Quality Assurance Program Description, when complete, is designed to provide a level of confidence in the integrity of the canistered waste forms. 8 refs

  10. Quality assurance of packaging used for the transport of radioactive material

    International Nuclear Information System (INIS)

    Oeman, S.

    1987-01-01

    The project is divided into four parts. This document is the final report from part 2 and 3. The aim of the project is a document called 'Proposal for quality assurance of packaging used for the transport of radioactive material' which shall act as an example for how the quality assurance should be organized for different categories of packagings. One or more specific packagings ('type packagings') in each class have been selected and studied in detail with consideration on the components which are important for the safety at transportation. Finally detailed control plans have been developed with consideration to production quality control as well as to recurring inspection. Besides it has been investigated whether there are any control methods to carry out the necessary inspections according to the control plans and report where such methods have to be developed. (author)

  11. System management and quality assurance

    International Nuclear Information System (INIS)

    Sastry, A.M.

    1989-01-01

    This paper describes the principles of system management and shows the relationship to quality assurance. It discusses the need for balanced attention to all the project management controls required for project success

  12. Quality Assurance Planning for Region 9

    Science.gov (United States)

    The ultimate success of an environmental program or project depends on the quality of the environmental data collected and used in decision-making. EPA has developed guidances to help state and tribal governments develop Quality Assurance Program Plans.

  13. Concrete quality assurance

    Energy Technology Data Exchange (ETDEWEB)

    Holz, N. [Harza Engineering Company, Chicago, IL (United States)

    2000-08-01

    This short article reports on progress at the world's largest civil construction project, namely China's Three Gorges hydro project. Work goes on around the clock to put in place nearly 28 M m{sup 3} of concrete. At every stage of the work there is strong emphasis on quality assurance (QA) and concrete is no exception. The US company Harza Engineering has been providing QA since the mid-1980s and concrete QA has been based on international standards. Harza personnel work in the field with supervisors developing educational tools for supervising concrete construction and quality, as well as providing training courses in concrete technology. Some details on flood control, capacity, water quality and environmental aspects are given..

  14. Quality assurance of qualitative research: a review of the discourse.

    Science.gov (United States)

    Reynolds, Joanna; Kizito, James; Ezumah, Nkoli; Mangesho, Peter; Allen, Elizabeth; Chandler, Clare

    2011-12-19

    Increasing demand for qualitative research within global health has emerged alongside increasing demand for demonstration of quality of research, in line with the evidence-based model of medicine. In quantitative health sciences research, in particular clinical trials, there exist clear and widely-recognised guidelines for conducting quality assurance of research. However, no comparable guidelines exist for qualitative research and although there are long-standing debates on what constitutes 'quality' in qualitative research, the concept of 'quality assurance' has not been explored widely. In acknowledgement of this gap, we sought to review discourses around quality assurance of qualitative research, as a first step towards developing guidance. A range of databases, journals and grey literature sources were searched, and papers were included if they explicitly addressed quality assurance within a qualitative paradigm. A meta-narrative approach was used to review and synthesise the literature. Among the 37 papers included in the review, two dominant narratives were interpreted from the literature, reflecting contrasting approaches to quality assurance. The first focuses on demonstrating quality within research outputs; the second focuses on principles for quality practice throughout the research process. The second narrative appears to offer an approach to quality assurance that befits the values of qualitative research, emphasising the need to consider quality throughout the research process. The paper identifies the strengths of the approaches represented in each narrative and recommend these are brought together in the development of a flexible framework to help qualitative researchers to define, apply and demonstrate principles of quality in their research. © 2011 Reynolds et al; licensee BioMed Central Ltd.

  15. The Columbia River Protection Supplemental Technologies Quality Assurance Project Plan

    International Nuclear Information System (INIS)

    Fix, Anne

    2007-01-01

    The U.S. Department of Energy (DOE) has conducted interim groundwater remedial activities on the Hanford Site since the mid-1990s for several groundwater contamination plumes. DOE established the Columbia River Protection Supplemental Technologies Project (Technologies Project) in 2006 to evaluate alternative treatment technologies. The objectives for the technology project are as follows: develop a 300 Area polyphosphate treatability test to immobilize uranium, design and test infiltration of a phosphate/apatite technology for Sr-90 at 100-N, perform carbon tetrachloride and chloroform attenuation parameter studies, perform vadose zone chromium characterization and geochemistry studies, perform in situ biostimulation of chromium studies for a reducing barrier at 100-D, and perform a treatability test for phytoremediation for Sr-90 at 100-N. This document provides the quality assurance guidelines that will be followed by the Technologies Project. This Quality Assurance Project Plan is based on the quality assurance requirements of DOE Order 414.1C, Quality Assurance, and 10 CFR 830, Subpart A--Quality Assurance Requirements as delineated in Pacific Northwest National Laboratory?s Standards-Based Management System. In addition, the technology project is subject to the Environmental Protection Agency (EPA) Requirements for Quality Assurance Project Plans (EPA/240/B-01/003, QA/R-5). The Hanford Analytical Services Quality Assurance Requirements Documents (HASQARD, DOE/RL-96-68) apply to portions of this project and to the subcontractors. HASQARD requirements are discussed within applicable sections of this plan.

  16. Quality assurance as a management tool in decommissioning activities

    International Nuclear Information System (INIS)

    Arter, D.R.

    1982-01-01

    Quality assurance practices have been applied to the peaceful use of nuclear energy for many years. These practices are just as useful to the back end of the nuclear energy cycle as they are to the front end. The Department of Energy requires the application of quality assurance to all of its projects and programs. Quality assurance as a management tool consists of three fundamental elements: planning, execution and control. These elements should be applied to decommissioning activities by all parties, such that limited funds are wisely spent and the public is adequately protected

  17. References on EPA Quality Assurance Project Plans

    Science.gov (United States)

    Provides requirements for the conduct of quality management practices, including quality assurance (QA) and quality control (QC) activities, for all environmental data collection and environmental technology programs performed by or for this Agency.

  18. An operational health physics quality assurance program

    International Nuclear Information System (INIS)

    Costigan, S.A.; McAtee, J.L. III; Somers, W.M.; Huchton, R.L.

    1996-01-01

    DOE Order 5700.6C, Quality Assurance, stipulates QA requirements for all DOE activities. This order is now codified as 10CFR830.120, Nuclear Safety Management, Quality Assurance Requirements, which is applicable to DOE nuclear facilities. A Quality Assurance Management Plan (QAMP) was developed by the Health Physics Operations Group (ESH-1) at Los Alamos National Laboratory (LANL). The goal of the ESH-1 QAMP is to ensure that operational radiation protection activities meet the criteria outlined in DOE Order 5700.6C, DOE-ER-STD-6001-92 and 10CFR830.120. The ten required elements are QA Program, Personal Training and Qualifications, Quality Improvement, Documents and Records, Work Processes, Design, Procurement, Inspection and Acceptance Testing, Management Assessment and Independent Assessment. The QAMP has been useful for the development of QAMPs at nuclear facilities and has helped ensure uniformity of institutional requirements where Health Physics services are deployed to facilities. To implement a subset of QAMP requirements, a Quality Assurance Self-Evaluation Program (QASE) was established. This program provides a novel self-audit mechanism for the formal identification and correction of non-conforming items related to Operational Health Physics. Additionally, the QASE is a useful management tool for Radiological Control Technician Supervisors and staff and provides a tracking mechanism for ongoing problem areas. Data have been Collected for two calendar years on a number of concerns that fall into four general categories: radiological posting and labeling, instrumentation, monitoring requirements, and radiological documents/records

  19. Quality assurance program for isotopic power systems

    International Nuclear Information System (INIS)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented

  20. Quality assurance program for isotopic power systems

    Energy Technology Data Exchange (ETDEWEB)

    Hannigan, R.L.; Harnar, R.R.

    1982-12-01

    This report summarizes the Sandia National Laboratories Quality Assurance Program that applies to non-weapon (reimbursable) Radioisotopic Thermoelectric Generators. The program has been implemented over the past 16 years on power supplies used in various space and terrestrial systems. The quality assurance (QA) activity of the program is in support of the Department of Energy, Office of Space Nuclear Projects. Basic elements of the program are described in the report and examples of program decumentation are presented.

  1. Manufacture of heavy reactor components with particular considerations to quality assurance

    International Nuclear Information System (INIS)

    Kreppel, H.; Clausmeyer, H.

    1980-01-01

    The use of adequate quality assurance measures is one of the most important prerequisites for the manufacture of reactor components. Nature and extent of the quality assurance system at present adopted in the Federal Republic of Germany are illustrated, using the manufacture of a reactor pressure vessel as an example. The system comprises quality organization, planning of all quality assurance measures, quality surveillance through all stages of manufacture and documentation of quality attained. (orig.)

  2. Manufacture of heavy reactor components with particular consideration to quality assurance

    International Nuclear Information System (INIS)

    Clausmeyer, H.; Kreppel, H.

    1977-01-01

    The use of adequate quality assurance measures is one of the most important prerequisites for the manufacture of reactor components. Nature and extent of the quality assurance system at present adopted in the Federal Republic of Germany are illustrated, using the manufacture of a reactor pressure vessel as an example. The system comprises quality organization, planning of all quality assurance measures, quality surveillance through all stages of manufacture and documentation of quality attained. (orig.) [de

  3. Manufacture of heavy reactor components with particular consideration to quality assurance

    International Nuclear Information System (INIS)

    Kreppel, H.; Clausmeyer, H.

    1981-01-01

    The use of adequate quality assurance measures is one of the most important prerequisites for the manufacture of reactor components. Nature and extent of the quality assurance system at present adopted in the Federal Republic of Germany are illustrated, using the manufacture of a reactor pressure vessel as an example. The system comprises quality organization, planning of all quality assurance measures, quality surveillance through all stages of manufacture and documentation of quality attained. (orig.)

  4. Quality assurance programs from laboratories offering radiological protection services

    International Nuclear Information System (INIS)

    Marrero Garcia, M.; Prendes Alonso, M.; Jova Sed, L.; Morales Monzon, J.A.

    1998-01-01

    The implementation of an adequate program for quality assurance in institutions servicing radiological protection programs will become an additional tool to achieve security targets included in that program. All scientific and technical services offered by CPHR employ quality assurance systems

  5. [Quality assurance in dentistry--past, present and future].

    Science.gov (United States)

    Vered, Y; Schwartz, N; Babayoff, I

    2003-01-01

    Quality assurance involves the cycle of quality assessment, formal identification of problems, developing a strategy for resolving problems and implementation of changes. Historically, the term "first do not harm" can be considered as the first step in quality assurance. Patients' high expectations from the outcomes of dental treatment, new technology and cost containment changed the perspectives completely. We are facing a new era of an increasing demand for patients' involvement as well as an increasing demand for accountability of the members of the profession. The article describes the development of the issue of quality assurance during the last thirty years and highlights the difficulties encountered by the profession in adjusting the changes due to lack of education, experience, knowledge and absence of a definition for accepted criteria for action. Developing criteria for appropriateness of dental treatment, developing mechanisms for assessing the art of care, development of large data bases and development of consumers' surveys are some of the leading suggestions for future action. The responsibility for quality and quality assurance lies in the hands of the dental profession. Organized dentistry possesses a social and ethical commitment for the society, as well as professional obligation for the members of the profession. Although cost containment gave rise to the issue of quality, quality assurance should not be measured in financial terms, but in terms of accepting responsibility and working for continuous improvement. Steps in the right direction will, hopefully, lead to a better and more efficient utilization of the available resources and will increase the trust of the public in the profession of dentistry. Therefore, organized dentistry should not leave this important issue to be dealt by non-dental professions or commercial organizations.

  6. Quality Assurance Program Plan for the Waste Sampling and Characterization Facility

    International Nuclear Information System (INIS)

    Grabbe, R.R.

    1995-01-01

    The objective of this Quality Assurance Plan is to provide quality assurance (QA) guidance, implementation of regulatory QA requirements, and quality control (QC) specifications for analytical service. This document follows the Department of Energy (DOE)-issued Hanford Analytical Services Quality Assurance Plan (HASQAP) and additional federal [10 US Code of Federal Regulations (CFR) 830.120] QA requirements that HASQAP does not cover. This document describes how the laboratory implements QA requirements to meet the federal or state requirements, provides what are the default QC specifications, and/or identifies the procedural information that governs how the laboratory operates. In addition, this document meets the objectives of the Quality Assurance Program provided in the WHC-CM-4-2, Section 2.1. This document also covers QA elements that are required in the Guidelines and Specifications for Preparing Quality Assurance Program Plans (QAPPs), (QAMS-004), and Interim Guidelines and Specifications for Preparing Quality Assurance Product Plans (QAMS-005) from the Environmental Protection Agency (EPA). A QA Index is provided in the Appendix A

  7. Quality assurance for electronic portal imaging devices

    International Nuclear Information System (INIS)

    Shalev, S.; Rajapakshe, R.; Gluhchev, G.; Luchka, K.

    1997-01-01

    Electronic portal imaging devices (EPIDS) are assuming an ever-increasing role in the verification of radiation treatment accuracy. They are used both in a passive capacity, for the determination of field displacement distributions (''setup errors''), and also in an active role whereby the patient setup is corrected on the basis of electronic portal images. In spite of their potential impact on the precision of patient treatment, there are few quality assurance procedures available, and most of the EPIDS in clinical use are subject, at best, to only perfunctory quality assurance. The goals of this work are (a) to develop an objective and reproducible test for EPID image quality on the factory floor and during installation of the EPID on site; (b) to provide the user with a simple and accurate tool for acceptance, commissioning, and routine quality control; and (c) to initiate regional, national and international collaboration in the implementation of standardized, objective, and automated quality assurance procedures. To this end we have developed an automated test in which a simple test object is imaged daily, and the spatial and contrast resolution of the EPID are automatically evaluated in terms of ''acceptable'', ''warning'' and ''stop'' criteria. Our experience over two years shows the test to be highly sensitive, reproducible, and inexpensive in time and effort. Inter-institutional trials are under way in Canada, US and Europe which indicate large variations in EPID image quality from one EPID to another, and from one center to another. We expect the new standardized quality assurance procedure to lead to improved, and consistent image quality, increased operator acceptance of the technology, and agreement on uniform standards by equipment suppliers and health care agencies. (author)

  8. [Topic identification for cross-sectoral quality assurance in stroke and TIA treatment].

    Science.gov (United States)

    Meyer, Sven; Willms, Gerald; Broge, Björn; Szecsenyi, Joachim

    2016-10-01

    The development of cross-sectoral quality assurance programs usually requires extensive topic identification. Illustrated by the complex processes of care for stroke and transient ischemic attacks (TIAs), a method for comprehensive topic identification is presented. The first step involves a thorough literature search in terms of systematic reviews, health technology assessments, guidelines, studies into healthcare delivery and the use of specific instruments. Routine data as well as epidemiologic studies are used to analyze the reality of service provision. In addition, experts are consulted to gain expertise concerning deficits of care, approaches to quality assurance and experience with existing quality assurance programs. Furthermore individual patient experiences are collected to add the patients' perceptions of care. Because of the limitation on the regulatory scope of Book V of the German Social Code, which, in this case, was necessary, another source of information was the legal framework and its impact on rescue chain, acute treatment and rehabilitation. Existent quality management systems, accreditations and quality assurance programs in prevention, acute treatment and rehabilitation have been searched in order to avoid any overlap with existing measures. After identifying a total of 71 quality targets according to deficits of care, recommendations for care and expert opinions in primary and secondary prevention, rescue chain, acute treatment, rehabilitation and supply of assistive equipment and therapies, respectively, the usability of instruments was tested. These instruments included case documentation, patient surveys and routine data. 14 quality targets proved to be reproducible by these instruments and were included in the recommendations for a cross-sectoral quality assurance program for stroke and TIA. Copyright © 2016. Published by Elsevier GmbH.

  9. Quality assurance in the fuel fabrication

    International Nuclear Information System (INIS)

    Darmayan, P.

    1995-01-01

    The paper concentrates on the evolutions that FBFC Franco Belge de Fabrication de Combustible has initiated in order to make a further step in improving quality: 1. Improving each personnel's involment and responsability towards quality. 2. Incorporating quality assurance in a total quality management policy, involving both the fabrication teams of FBFC and the design teams of Framatome in order to improve quality. (orig./HP)

  10. An In-Depth Study on the Impact of External Quality Assurance

    Science.gov (United States)

    Stensaker, Bjorn; Langfeldt, Liv; Harvey, Lee; Huisman, Jeroen; Westerheijden, Don

    2011-01-01

    After more than two decades of external quality assurance, there is an increasing interest in questions concerning the impact and effects of this activity. Following an external evaluation of NOKUT--the Norwegian quality assurance agency, this article studies the impact of external quality assurance in detail by analysing quantitative and…

  11. International Thermonuclear Experimental Reactor U.S. Home Team Quality Assurance Plan

    Energy Technology Data Exchange (ETDEWEB)

    Sowder, W. K.

    1998-10-01

    The International Thermonuclear Experimental Reactor (ITER) project is unique in that the work is divided among an international Joint Central Team and four Home Teams, with the overall responsibility for the quality of activities performed during the project residing with the ITER Director. The ultimate responsibility for the adequacy of work performed on tasks assigned to the U.S. Home Team resides with the U.S. Home Team Leader and the U.S. Department of Energy Office of Fusion Energy (DOE-OFE). This document constitutes the quality assurance plan for the ITER U.S. Home Team. This plan describes the controls exercised by U.S. Home Team management and the Performing Institutions to ensure the quality of tasks performed and the data developed for the Engineering Design Activities assigned to the U.S. Home Team and, in particular, the Research and Development Large Projects (7). This plan addresses the DOE quality assurance requirements of 10 CFR 830.120, "Quality Assurance." The plan also describes U.S. Home Team quality commitments to the ITER Quality Assurance Program. The ITER Quality Assurance Program is based on the principles described in the International Atomic Energy Agency Standard No. 50-C-QA, "Quality Assurance for Safety in Nuclear Power Plants and Other Nuclear Facilities." Each commitment is supported with preferred implementation methodology that will be used in evaluating the task quality plans to be submitted by the Performing Institutions. The implementing provisions of the program are based on guidance provided in American National Standards Institute/American Society of Mechanical Engineers NQA-1 1994, "Quality Assurance." The individual Performing Institutions will implement the appropriate quality program provisions through their own established quality plans that have been reviewed and found to comply with U.S. Home Team quality assurance plan commitments to the ITER Quality Assurance Program. The extent of quality program provisions

  12. Implementing hospital quality assurance policies in Iran: balancing licensing, annual evaluation, inspections and quality management systems.

    Science.gov (United States)

    Aghaei Hashjin, Asgar; Delgoshaei, Bahram; Kringos, Dionne S; Tabibi, Seyed Jamaladin; Manouchehri, Jila; Klazinga, Niek S

    2015-01-01

    The purpose of this paper is to provide an overview of applied hospital quality assurance (QA) policies in Iran. A mixed method (quantitative data and qualitative document analysis) study was carried out between 1996 and 2010. The QA policy cycle forms a tight monitoring system to assure hospital quality by combining mandatory and voluntary methods in Iran. The licensing, annual evaluation and grading, and regulatory inspections statutorily implemented by the government as a national package to assure and improve hospital care quality, while implementing quality management systems (QMS) was voluntary for hospitals. The government's strong QA policy legislation role and support has been an important factor for successful QA implementation in Iran, though it may affected QA assessment independency and validity. Increased hospital evaluation independency and repositioning, updating standards, professional involvement and effectiveness studies could increase QA policy impact and maturity. The study highlights the current QA policy implementation cycle in Iranian hospitals. It provides a basis for further quality strategy development in Iranian hospitals and elsewhere. It also raises attention about finding the optimal balance between different QA policies, which is topical for many countries. This paper describes experiences when implementing a unique approach, combining mandatory and voluntary QA policies simultaneously in a developing country, which has invested considerably over time to improve hospital quality. The experiences with a mixed obligatory/voluntary approach and comprehensive policies in Iran may contain lessons for policy makers in developing and developed countries.

  13. Optimisation of small-scale hydropower using quality assurance methods - Preliminary project; Vorprojekt: Optimierung von Kleinwasserkraftwerken durch Qualitaetssicherung. Programm Kleinwasserkraftwerke

    Energy Technology Data Exchange (ETDEWEB)

    Hofer, S.; Staubli, T.

    2006-11-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents the results of a preliminary project that examined how quality assurance methods can be used in the optimisation of small-scale hydropower projects. The aim of the project, to use existing know-how, experience and synergies, is examined. Discrepancies in quality and their effects on production prices were determined in interviews. The paper describes best-practice guidelines for the quality assurance of small-scale hydro schemes. A flow chart describes the various steps that have to be taken in the project and realisation work. Information collected from planners and from interviews made with them are presented along with further information obtained from literature. The results of interviews concerning planning work, putting to tender and the construction stages of these hydro schemes are presented and commented on. Similarly, the operational phase of such power plant is also examined, including questions on operation and guarantees. The aims of the follow-up main project - the definition of a tool and guidelines for ensuring quality - are briefly reviewed.

  14. Quality assurance and evidence in career guidance in Europe

    DEFF Research Database (Denmark)

    Plant, Peter

    2011-01-01

    Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected.......Quality assurance and evidence in career guidance in Europe is based on a particular, positivtic model. Other approaches are largely neglected....

  15. Quality assurance standards of nuclear equipment and international cooperation

    International Nuclear Information System (INIS)

    Savanger, J.M.

    1983-01-01

    This paper analyses the quality assurance system; it briefly defines the meaning of this concept and assesses the status of quality assurance in France. The author also reviews the problems and difficulties encountered in the setting up of this system. (NEA) [fr

  16. Quality assurance in the project of RECH-2 research reactor

    International Nuclear Information System (INIS)

    Goycolea Donoso, C.; Nino de Zepeda Schele, A.

    1989-01-01

    The implantation of a Quality Assurance Program for the design, supply, construction, installation, and testing of the RECH-2 research reactor, is described in this paper. The obtained results, demonstrate that a Quality Assurance Program constitutes a suitable mean to assure that the installation complies with the safety and reliability requirements. (author)

  17. Practical aspects of quality assurance in nuclear power plants in Japan

    International Nuclear Information System (INIS)

    Inoue, Kunio

    1980-01-01

    Based on the occurrence of accidents caused by inappropriateness in quality assurance in nuclear power plants, the nuclear power plant quality assurance investigation committee was organized in January, 1980, to examine comprehensively what the quality assurance should be from designing through operating stages of the equipments and systems of nuclear power stations, in order to prevent the recurrence of such accidents, to secure the safety and to improve the reliability. The committee established three subcommittees: the first is in charge of the investigation of quality assurance system based on the analyses of accidents, failures or abnormal events, the second in charge of the investigation of quality assurance system in nuclear industries, and the third in charge of the investigation by comparing domestic legal control and the organization for implementing inspection with those of foreign countries. In nuclear power plants in Japan, approximately 20 accidents or failures have occurred every year in the last 3 or 4 years. Many of them seem to be caused by quality assurance problems such as the misuse of materials or the inadequacy in machining. In addition, to this paper the tables showing the general quality assurance activity in, and the present status of permission, approval and inspection for Japanese nuclear power plants are attached. (Wakatsuki, Y.)

  18. Mechanisms for Quality Assurance of Universities in Cameroon

    Directory of Open Access Journals (Sweden)

    Joseph BESONG BESONG

    2016-06-01

    Full Text Available This paper takes a perspective look at the evolution of universities in Cameroon and the recent orientation of deregulation as it affects quality assurance in Cameroonian universities. The paper having identified these flaws attempted to elucidate the meaning of mechanism for Quality assurance in the face of deregulation. The regulatory mechanisms identified by this paper include inter- alia, appropriate scrutiny of new programmes, relying on impartial advise of examiners. Using the state law NO.98/004 of 1998 to compliment the efforts of internal school administration and above all opening linkages between universities and relating universities education in the World of science and technology. This paper does not only enhance quality assurance but also builds the idea of economic growth and development.

  19. Trading Quality across Borders: Colonial Discourse and International Quality Assurance Policies in Higher Education

    Science.gov (United States)

    Blanco Ramírez, Gerardo

    2014-01-01

    Accountability and quality assurance have become central discourses in higher education policy throughout the world. However, accountability and quality assurance involve power and control. Practices and ideas about quality developed in the Global North are spreading rapidly across the Global South, leading to increased uniformity in the…

  20. Power transformers quality assurance

    CERN Document Server

    Dasgupta, Indrajit

    2009-01-01

    About the Book: With the view to attain higher reliability in power system operation, the quality assurance in the field of distribution and power transformers has claimed growing attention. Besides new developments in the material technology and manufacturing processes of transformers, regular diagnostic testing and maintenance of any engineering product may be ascertained by ensuring: right selection of materials and components and their quality checks. application of correct manufacturing processes any systems engineering. the user`s awareness towards preventive maintenance. The

  1. Quality assurance inspections in the transportation packaging supplier industry

    International Nuclear Information System (INIS)

    Jankovich, J.P.

    1991-01-01

    In this paper the quality assurance inspections of the transportation packaging supplier industry, conducted by the U.S. Nuclear Regulatory Commission (NRC) on a routine basis since 1989 are discussed. The term supplier is used to include designers, fabricators, and distributors that hold NRC approved Quality Assurance Programs and Certificates of Compliance for packagings to transport radioactive materials. The objective of the inspections is to provide assurance that transportation packagings are fabricated and procured in accordance with 10 CFR Parts 21 and 71 requirements. The inspections are conducted in a systematic and comprehensive manner, utilizing uniform inspection techniques in order to assure uniformity and comparability. During the April 1989 and May 1991 period approximately 21 inspections were conducted by the Transportation Branch, Office of Nuclear Material Safety and Safeguards of the NRC. The majority of the findings were identified in the areas of quality assurance procedures, control of special processes (e.g. welding, radiography), and maintenance of QA records

  2. Quality Assurance Program Description

    Energy Technology Data Exchange (ETDEWEB)

    Halford, Vaughn Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Ryder, Ann Marie [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-07-01

    Effective May 1, 2017, led by a new executive leadership team, Sandia began operating within a new organizational structure. National Technology and Engineering Solutions of Sandia (Sandia’s) Quality Assurance Program (QAP) was established to assign responsibilities and authorities, define workflow policies and requirements, and provide for the performance and assessment of work.

  3. Traps in quality assurance of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Meier, N.; Lenzen, H.; Fiebich, M.

    1992-01-01

    With the introduction of the German industrial protocol for quality assurance of X-ray equipment, everybody using X-ray machines fell into sort of trap or found some of the procedures misleading. Vigorous discussions were held on every conceivable aspect of this and other protocols, and are still in progress. This paper points out some of the common traps and considers a new type dosimeter, which allows a definite separation of quality assurance of X-ray equipment and of processing and which can also be used in future for quality assurance of digital radiography equipment. (orig.) [de

  4. Physical aspects of quality assurance in cobalt teletherapy units

    Energy Technology Data Exchange (ETDEWEB)

    Ng, Kwan Hong [Malaya Univ., Kuala Lumpur (Malaysia)

    1989-06-01

    ICRU Report No. 24 states that +- 5% is a reasonable degree of accuracy to strive for in the delivery of absorbed doses to target volumes in radiotherapy. To achieve this quality assurance level, a comprehensive programme comprising both physical and clinical components is needed. The purpose of this paper is to present the rationale and guidelines for implementing a recommended quality assurance programme. It will emphasize the physical aspects pertaining to acceptance and constancy tests using Cobalt-60 teletherapy units. It will also outline a suggested schedule of quality assurance testings including radiation dosimetry, geometry and electrochemical safety. (author).

  5. Quality assurance during site construction. Pt. 1

    International Nuclear Information System (INIS)

    Mueller, J.

    1980-01-01

    The first part of the lecture deals with the Quality Assurance system on the construction site in general. Basic site-related problems during contract implementation and the QA system requirements resulting from them are presented. The compilation of these requirements in a QA program and its inclusion in the site manual in written form are explained. Site organization, personnel qualification and procedures are referred to. Whereas the first part shows what is to be done, the second part shows how it can be put into practice on the site. All the essential points for the assurance of quality are addressed. They include, e.g., review of documents, incoming goods control, in-process surveillance, store controls, identification of components and systems, dealing with changes and deviations, documentation control and audits. By means of examples taken form practice the necessity of a well-functioning QA system, and the importance of quality-assuring measures on the site are pointed out. (orig.)

  6. [Quality assurance in oncology: experiences of an ISO certification].

    Science.gov (United States)

    Szentirmay, Zoltán; Cseh, Lujza; Ottó, Szabolcs; Kásler, Miklós

    2002-01-01

    The ISO 9001 quality assurance of the National Institute of Oncology has been achieved successfully. We give an account of the brief history and the structure of the assurance system of the Institute, the process of setting our goals, and also the experience gained from drafting ISO 9001 handbook and flowcharts. Apart from the bureaucratic nature of quality assurance, it is a good opportunity for us to investigate our everyday work, put it into orderly manner and work more reliably. Experience has shown that the introduction of a quality assurance system increases the level of patient care, the documentation helps the Institute or some of its departments, or even individuals prevent law suits, and serves as a sound basis for proposing promotion, salary increases and bonuses, or even honors.

  7. The Role Of Quality Assurance Program For Safety Operation Of Nuclear Installations

    International Nuclear Information System (INIS)

    Harjanto, N.T.; Purwadi, K.P.; Boru, D.S.; Farida; Suharni

    2000-01-01

    Nuclear installations expose potential hazard of radiation, therefore in their construction, operation and maintenance, it is necessary to consider safety aspect, in which the safety requirements which has been determined must be met. One of the requirements that is absolutely needed is quality assurance, which covers arrangement of quality assurance program, organization and administration of the implementation of quality assurance, and supervision. Quality Assurance program is a guideline containing quality policies and basic determination on the realization of activities that effect the quality of equipment's and items used in the operation of nuclear installations in order that the operation of nuclear installation can run safety and in accordance with their design aims and operation limits. Quality Assurance Program includes document control, design control, supply control, control of equipment s and items, operation/process control, inspection and control of equipment test, and control of nonconformance and corrections. General system of nuclear installation operation is equipped with safety and supporting systems. These systems must apply the quality assurance program that cover control of activities in the systems. In the implementation of the quality assurance program, it is necessary to establish procedures, work guidelines/instructions, and quality recording that constitutes documents of quality system 2 nd , 3 th , and 4 th level after the quality assurance program. To ensure the effectivity and to prove whether the realization of the program has been pursuant to the determined requirements, an internal audit must be conducted accordingly

  8. Quality Assurance in the Presence of Variability

    Science.gov (United States)

    Lauenroth, Kim; Metzger, Andreas; Pohl, Klaus

    Software Product Line Engineering (SPLE) is a reuse-driven development paradigm that has been applied successfully in information system engineering and other domains. Quality assurance of the reusable artifacts of the product line (e.g. requirements, design, and code artifacts) is essential for successful product line engineering. As those artifacts are reused in several products, a defect in a reusable artifact can affect several products of the product line. A central challenge for quality assurance in product line engineering is how to consider product line variability. Since the reusable artifacts contain variability, quality assurance techniques from single-system engineering cannot directly be applied to those artifacts. Therefore, different strategies and techniques have been developed for quality assurance in the presence of variability. In this chapter, we describe those strategies and discuss in more detail one of those strategies, the so called comprehensive strategy. The comprehensive strategy aims at checking the quality of all possible products of the product line and thus offers the highest benefits, since it is able to uncover defects in all possible products of the product line. However, the central challenge for applying the comprehensive strategy is the complexity that results from the product line variability and the large number of potential products of a product line. In this chapter, we present one concrete technique that we have developed to implement the comprehensive strategy that addresses this challenge. The technique is based on model checking technology and allows for a comprehensive verification of domain artifacts against temporal logic properties.

  9. Ensuring Quality Assurance in Vocational Education

    Science.gov (United States)

    Idialu, Ethel E.

    2013-01-01

    Vocational education emphasises skill acquisition. Quality assurance in vocational education is a concept that is concerned with high performance involving activities with vocational education such as teaching, learning, infrastructures, students' behaviour and the entire academic process. Quality vocational education refers to input and output of…

  10. LASL computerized quality assurance record-keeping system for analytical chemistry

    International Nuclear Information System (INIS)

    Dahlby, J.W.; Phillips, J.R.

    1976-06-01

    Research programs requiring quality assurance surveillance, certification procedures, and associated record keeping have increased markedly at the Los Alamos Scientific Laboratory. A computer-based system, accessible through time-sharing terminals, performs many routine operations, including continued records updating for equipment calibration, personnel certification, quality assurance procedure listings, and controlled-document distribution lists. The system described has operated successfully for more than a year, resulting in a significant savings in man-hours required to keep quality assurance records

  11. Development of quality assurance procedures for production of sealed radiation source

    CERN Document Server

    Nam, J H; Cho, W K; Han, H S; Hong, S B; Kim, K H; Kim, S D; Lee, Y G; Lim, N J

    2001-01-01

    The quality assurance procedures for sealed radiation sources production using HANARO and RIPF have been developed. The detailed quality assurance procedures are essential to manage the whole work process effectively and ensure the quality of the produced sealed sources. Through applying this quality assurance procedures to the entire production works of the sealed radiation sources, it is expected that the quality of the products, the safety of the works and the satisfaction of the customers will be increased.

  12. Guideline for Technical Quality Assurance (TQA) of Ultrasound devices (B-Mode) - Version 1.0 (July 2012)

    NARCIS (Netherlands)

    Kollmann, C.; Korte, C.L. de; Dudley, N.J.; Gritzmann, N.; Martin, K.; Evans, D.H.

    2012-01-01

    The Technical Quality Assurance group was initiated by the EFSUMB Board in 2007 and met firstly in 2008 to discuss and evaluate methods and procedures published for performing technical quality assurance for diagnostic ultrasound devices. It is the aim of this group of experts to advise the EFSUMB

  13. Near-facility environmental monitoring quality assurance project plan

    International Nuclear Information System (INIS)

    McKinney, S.M.

    1997-01-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the activities associated with the preoperational and near facility environmental monitoring performed by Waste Management Federal Services, Inc., Northwest Operations and supersedes WHC-EP-0538-2. This plan applies to all sampling and monitoring activities performed by waste management Federal Services, Inc., Northwest Operations in implementing facility environmental monitoring at the Hanford Site

  14. Quality assurance experience in the manufacture of PFBR reactor vessel during technology development work

    International Nuclear Information System (INIS)

    Shanmugam, K.; Chandramohan, R.; Ramamurthy, M.K.

    1996-01-01

    An efficient and proper implementation of quality assurance in the technology development works of Prototype Fast Breeder Reactor (PFBR) main vessel was undertaken to achieve the desired quality and dimensional accuracy of main vessel. In this paper an attempt has been made to bring out the methods and procedures adopted to implement the quality assurance programme on important activities including approval of documents, material, general requirements for manufacture of SS components, inspection procedures, forming and welding of petals, non-destructive testing etc. (author)

  15. Quality assurance requirements for packaging and transportation of radioactive materials

    International Nuclear Information System (INIS)

    Barker, R.F.; MacDonald, C.E.; Doda, R.J.

    1978-01-01

    This paper discusses the new quality assurance regulations of the Nuclear Regulatory Commission (NRC) for packaging and transportation of radioactive materials. These regulations became effective on October 18, 1977. Background information concerning these regulations and packaging and transportation history is included. The quality assurance program is described with indications of how it is composed of general (administrative) provisions which must meet the 18 quality assurance criteria and be approved by the NRC; specific provisions which appear in the DOT and NRC regulations and in the individual package design approval; and other specific procedures which are not required by regulations but which are necessary for the proper control of quality. The quality assurance program is to be developed using a graded approach for the application of pertinent criteria and optimizing the required degree of safety and control efforts involved in achieving this level of safety. The licensee-user is responsible for all phases of quality assurance for packaging activities including: design, manufacture, test, use, maintenance and repair. The package design phase is considered to be particularly important in producing adequate safety in operational activities concerning packaging and transportation of radioactive materials

  16. Quality Assurance in Defense Adjudication Workshop for Defining and Assessing Quality

    National Research Council Canada - National Science Library

    Carney, Ralph

    2003-01-01

    ...) can adopt to assure the quality of adjudication decisions. Subject matter experts identified adjudication customers, products and services, and customer expectations and defined adjudication quality...

  17. Quality Assurance in Defense Adjudication: Workshop for Defining and Assessing Quality

    National Research Council Canada - National Science Library

    Carney, Ralph

    2002-01-01

    ...) can adopt to assure the quality of adjudication decisions. Subject matter experts identified adjudication customers, products and services, and customer expectations and defined adjudication quality...

  18. Regulating and Quality-Assuring VET: International Developments. Research Report

    Science.gov (United States)

    Misko, Josie

    2015-01-01

    The opening-up of the market for education and training, including vocational education and training (VET), has increased the importance of regulation and quality assurance mechanisms in ensuring the integrity of qualifications. This report investigates approaches to the regulation and quality assurance of vocational education and training in a…

  19. Interdisciplinary group of mammography (IGM). Quality assurance in mammography

    International Nuclear Information System (INIS)

    Anon.

    1994-01-01

    Assurance quality must be a preoccupation of each day in mammography. To be efficient and of low cost it must be discussed between radiologists and physicists; some countries like Federal Republic of Germany, Belgium, United Kingdom, Scandinavia and Netherlands engaged actions to make assurance quality a daily practice

  20. BUILDING "BRIDGES" WITH QUALITY ASSURANCE

    Science.gov (United States)

    The papr describes how, rather than building "bridges" across centuries, quality assurance (QA) personnel have the opportunity to build bridges across technical disciplines, between public and private organizations, and between different QA groups. As reviewers and auditors of a...

  1. Quality Assurance Project Plan for Facility Effluent Monitoring Plan activities

    International Nuclear Information System (INIS)

    Nickels, J.M.

    1991-06-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for the Facility Monitoring Plans of the overall site-wide environmental monitoring plan. This plan specifically applies to the sampling and analysis activities and continuous monitoring performed for all Facility Effluent Monitoring Plan activities conducted by Westinghouse Hanford Company. It is generic in approach and will be implemented in conjunction with the specific requirements of individual Facility Effluent Monitoring Plans. This document is intended to be a basic road map to the Facility Effluent Monitoring Plan documents (i.e., the guidance document for preparing Facility Effluent Monitoring Plans, Facility Effluent Monitoring Plan determinations, management plan, and Facility Effluent Monitoring Plans). The implementing procedures, plans, and instructions are appropriate for the control of effluent monitoring plans requiring compliance with US Department of Energy, US Environmental Protection Agency, state, and local requirements. This Quality Assurance Project Plan contains a matrix of organizational responsibilities, procedural resources from facility or site manuals used in the Facility Effluent Monitoring Plans, and a list of the analytes of interest and analytical methods for each facility preparing a Facility Effluent Monitoring Plan. 44 refs., 1 figs., 2 tabs

  2. The Soils and Groundwater – EM-20 S&T Roadmap Quality Assurance Project Plan

    Energy Technology Data Exchange (ETDEWEB)

    Fix, N. J.

    2008-02-11

    The Soils and Groundwater – EM-20 Science and Technology Roadmap Project is a U.S. Department of Energy, Office of Environmental Management-funded initiative designed to develop new methods, strategies and technology for characterizing, modeling, remediating, and monitoring soils and groundwater contaminated with metals, radionuclides, and chlorinated organics. This Quality Assurance Project Plan provides the quality assurance requirements and processes that will be followed by EM-20 Roadmap Project staff.

  3. Quality assurance or neo-imperialism

    DEFF Research Database (Denmark)

    Adriansen, Hanne Kirstine; Madsen, Lene Møller

    intention to do the opposite. Hence, we want to address how to make quality assurance can be made without imposing Western epistemologies. We call for an appreciation of different knowledges instead of mainstreaming in the name of internationalisation and globalisation. Capacity building of higher education...... in developing countries should ensure a broader perspective of educational quality in order not to lose knowledge diversity and wisdom....

  4. Quality Assurance Strategies for User Friendly School Libraries in ...

    African Journals Online (AJOL)

    This paper examines the methods of school library services with the purpose to promote quality assurance-in- Nigeria school libraries. The recurring theme in this paper is the imperative that school libraries in Nigeria should be committed and contributed to the transformation agenda which is the key issues of equity and ...

  5. Quality assurance in design: policy adopted by Vickers Barrow Engineering Works

    International Nuclear Information System (INIS)

    Aubrey, J.H.

    1976-01-01

    The quality assurance system operated by the Vickers Barrow Engineering Works is described, with special reference to the design of the reactor shield and above core structure for the first commercial fast reactor. Section headings are: introduction; what is quality assurance of design; attitude of designer; design discipline; customers attitude; Engineering Company system; future application of Design Quality Assurance Record system. (U.K.)

  6. Quality assurance for gamma knives

    International Nuclear Information System (INIS)

    Jones, E.D.; Banks, W.W.; Fischer, L.E.

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations

  7. Quality assurance for gamma knives

    Energy Technology Data Exchange (ETDEWEB)

    Jones, E.D.; Banks, W.W.; Fischer, L.E. [Lawrence Livermore National Lab., CA (United States)

    1995-09-01

    This report describes and summarizes the results of a quality assurance (QA) study of the Gamma Knife, a nuclear medical device used for the gamma irradiation of intracranial lesions. Focus was on the physical aspects of QA and did not address issues that are essentially medical, such as patient selection or prescription of dose. A risk-based QA assessment approach was used. Sample programs for quality control and assurance are included. The use of the Gamma Knife was found to conform to existing standards and guidelines concerning radiation safety and quality control of external beam therapies (shielding, safety reviews, radiation surveys, interlock systems, exposure monitoring, good medical physics practices, etc.) and to be compliant with NRC teletherapy regulations. There are, however, current practices for the Gamma Knife not covered by existing, formalized regulations, standards, or guidelines. These practices have been adopted by Gamma Knife users and continue to be developed with further experience. Some of these have appeared in publications or presentations and are slowly finding their way into recommendations of professional organizations.

  8. A Rotational Blended Learning Model: Enhancement and Quality Assurance

    Science.gov (United States)

    Ghoul, Said

    2013-01-01

    Research on blended learning theory and practice is growing nowadays with a focus on the development, evaluation, and quality assurance of case studies. However, the enhancement of blended learning existing models, the specification of their online parts, and the quality assurance related specifically to them have not received enough attention.…

  9. Quality Assurance Review of SKB's Copper Corrosion Experiments

    Energy Technology Data Exchange (ETDEWEB)

    Baldwin, Tamara D.; Hicks, Timothy W. (Galson Sciencies LTD. 5 Grosvenor House, Melton Road, Oakham (United Kingdom))

    2010-06-15

    SKB is preparing a license application for the construction of a final repository for spent nuclear fuel in Sweden. This application will be supported by the safety assessment SR-Site for the post-closure phase. The assessment of long-term safety is based on a broad range of experimental results from laboratory scale, intermediate scale and up to full scale experiments. It is essential that there is a satisfactory level of assurance that experiments have been carried out with sufficient quality, so that results can be considered to be reliable within the context of their use in safety assessment. The former named authority, SKI, has initiated a series of reviews of SKB's methods of quality assurance and their implementation. This quality assurance review is focused on the work of copper corrosion being conducted in at SKB's Hard Rock Laboratory (HRL) in Aespoe, LOT and Miniature canister (Minican) experiments. In order for the reviewers to get a broad understanding of the issue of copper corrosion both SKB reports as well as the viewpoint of MKG was collected prior to commencement of the actual review task. The purpose of this project is to assess SKB's quality assurance with the view of providing input for the preparation of the SR-Site safety assessment. This has been achieved by examination of the corrosion part of the LOT and Minican experiments using a check list, visits to the relevant facilities, and meetings with contractors and a few members of the SKB staff. The same approach for quality assurance reviews has been used earlier in similar review tasks. During the quality review of the selected projects, several QA- related issues of different degree of severity was noted by the reviewers. The most significant finding was that SKB has chosen to present only selected real-time corrosion monitoring data in TR-09-20. This was surprising and SSM expect that SKB will analyse the reason for this thoroughly. The reviewers also made other

  10. The grading management of the quality assurance

    International Nuclear Information System (INIS)

    Ma Xiaozheng; Han Shufang; Yu Bei; Tian Xuehang

    2009-01-01

    This paper introduces the quality assurance grading management of the items, services and technology process on nuclear power plants (nuclear island, conventional island, BOP), such as the requirements and aim in the related code, guide, technical document, the requirements for the related units, the grading principle and grading, the considering method for the differences of QA requirements of the each QA grand, as well as the status and propositions in the QA grading management in China. (authors)

  11. Quality assurance technical cooperation and training

    International Nuclear Information System (INIS)

    Chen, C.K.

    1993-01-01

    An IAEA Manual (TRS 340) which provides guidance for establishing training programme covering Quality Assurance principles and practices was published in 1992. The document is mainly based on the experience and material collected through the performance of some 50 interregional, regional and national training courses, seminars and workshops on Quality Assurance organized by the IAEA in about 20 countries. The purpose of this document is to provide a systematic approach for use by the responsible management in developing an overall QA training programme and lecture material for all personnel of a nuclear power plant. The document can be suitably adjusted for various management levels and adapted to the national variables and needs

  12. Hanford analytical services quality assurance plan. Revision 1

    International Nuclear Information System (INIS)

    1995-02-01

    This document, the Hanford Analytical Services Quality Assurance Plan (HASQAP), is issued by the U.S. Department of Energy, Richland Operations Office (RL). The HASQAP establishes quality requirements in response to U.S. Department of Energy (DOE) Order 5700.6C, Quality Assurance (10 CFR 830.120, open-quotes Quality Assurance Requirementsclose quotes). The HASQAP is designed to meet the needs of the RL for controlling the of analytical chemistry services provided by laboratory operations. The HASQAP is issued through the Analytical Services Branch of the Waste Management Division. The Analytical Services Branch is designated by the RL as having the responsibility for oversight management of laboratory operations under the Waste Management Division. The laboratories conduct sample analyses under several regulatory statutes, such as the Clean Air Act and the Clean Water Act. Sample analysis in support of the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) is a major role of the laboratory operations

  13. Large hadron collider (LHC) project quality assurance plan

    Energy Technology Data Exchange (ETDEWEB)

    Gullo, Lisa; Karpenko, Victor; Robinson, Kem; Turner, William; Wong, Otis

    2002-09-30

    The LHC Quality Assurance Plan is a set of operating principles, requirements, and practices used to support Berkeley Lab's participation in the Large Hadron Collider Project. The LHC/QAP is intended to achieve reliable, safe, and quality performance in the LHC project activities. The LHC/QAP is also designed to fulfill the following objectives: (1) The LHC/QAP is Berkeley Lab's QA program document that describes the elements necessary to integrate quality assurance, safety management, and conduct of operations into the Berkeley Lab's portion of the LHC operations. (2) The LHC/QAP provides the framework for Berkeley Lab LHC Project administrators, managers, supervisors, and staff to plan, manage, perform, and assess their Laboratory work. (3) The LHC/QAP is the compliance document that conforms to the requirements of the Laboratory's Work Smart Standards for quality assurance (DOE O 414.1, 10 CFR 830.120), facility operations (DOE O 5480.19), and safety management (DOE P 450.4).

  14. Large hadron collider (LHC) project quality assurance plan

    International Nuclear Information System (INIS)

    Gullo, Lisa; Karpenko, Victor; Robinson, Kem; Turner, William; Wong, Otis

    2002-01-01

    The LHC Quality Assurance Plan is a set of operating principles, requirements, and practices used to support Berkeley Lab's participation in the Large Hadron Collider Project. The LHC/QAP is intended to achieve reliable, safe, and quality performance in the LHC project activities. The LHC/QAP is also designed to fulfill the following objectives: (1) The LHC/QAP is Berkeley Lab's QA program document that describes the elements necessary to integrate quality assurance, safety management, and conduct of operations into the Berkeley Lab's portion of the LHC operations. (2) The LHC/QAP provides the framework for Berkeley Lab LHC Project administrators, managers, supervisors, and staff to plan, manage, perform, and assess their Laboratory work. (3) The LHC/QAP is the compliance document that conforms to the requirements of the Laboratory's Work Smart Standards for quality assurance (DOE O 414.1, 10 CFR 830.120), facility operations (DOE O 5480.19), and safety management (DOE P 450.4)

  15. Quality assurance

    International Nuclear Information System (INIS)

    Hiller, G.H.

    1979-01-01

    This compendium intends to give fast bibliographic information and to fill the visible gap between documentation and general bibliographic information. The reader is given an outline of quality assurance and some examples of techniques from the relevant literature. The practical engineer, who is always short of time, is thus offered a quick survey and a fast deepening of his understanding by means of literature dealing specifically with his unresolved problems. The mansucript has been kept in tis original form in order to speed up tis publication. The RKW technical department limited itself to checking its contents and the adherence to the established information goals. (orig.) 891 RW/orig. 892 MB [de

  16. Quality assurance and accreditation of engineering education in Jordan

    Science.gov (United States)

    Aqlan, Faisal; Al-Araidah, Omar; Al-Hawari, Tarek

    2010-06-01

    This paper provides a study of the quality assurance and accreditation in the Jordanian higher education sector and focuses mainly on engineering education. It presents engineering education, accreditation and quality assurance in Jordan and considers the Jordan University of Science and Technology (JUST) for a case study. The study highlights the efforts undertaken by the faculty of engineering at JUST concerning quality assurance and accreditation. Three engineering departments were accorded substantial equivalency status by the Accreditation Board of Engineering and Technology in 2009. Various measures of quality improvement, including curricula development, laboratories improvement, computer facilities, e-learning, and other supporting services are also discussed. Further assessment of the current situation is made through two surveys, targeting engineering instructors and students. Finally, the paper draws conclusions and proposes recommendations to enhance the quality of engineering education at JUST and other Jordanian educational institutions.

  17. An IEC standard on quality assurance for diagnostic X-ray systems

    International Nuclear Information System (INIS)

    Boer, J.A. den

    1985-01-01

    A presentation is given of some characteristics of the International Electrotechnical Commission (IEC). This is followed by a short discussion of general aspects of quality assurance in the diagnostic department. From this discussion it becomes apparent to which aspects of quality assurance IEC can contribute. Within that framework a working group of Sub-Committee 62 is at present active in developing a standard on quality assurance for diagnostic X-ray systems. The standard will contain a set of constancy tests that is claimed to allow a balanced quality assurance programme. The democratic procedure of IEC should guarantee that the proposed standard gains wide acceptance. (author)

  18. How much quality assurance?

    International Nuclear Information System (INIS)

    Beatty, R.A.; Talboy, J.H.

    1988-01-01

    This paper describes the approach used at Argonne National Laboratory to apply the techniques of quality assurance to research and development activities. The discussion includes the approach, the reasons that it is gaining acceptance, and its wide applicability. This approach is founded on the lessons learned in management of quality at Argonne National Laboratory over a period of more than 15 years. The discussion is confined to the practices at the Illinois site of the Laboratory where more than 3000 researchers and support personnel conduct basic and technology-directed research

  19. Implementation of quality assurance in the manufacture of radiation measuring instruments

    International Nuclear Information System (INIS)

    Erath, W.; Maushart, R.

    1993-01-01

    Contrary to a general belief, quality assurance in an instrument manufacturing plant comprises considerably more than the testing of instruments and components. Quality assurance programs according to the ISO 9000 standards are part of the general quality policy of a company, comprising management, manufacturing, sales, and service. A description of the quality assurance research and development is given, and the practical execution with regard to calibration of contamination monitors is pointed out in detail. (orig.) [de

  20. Development of a quality assurance system for radiotherapy

    International Nuclear Information System (INIS)

    Vroome, I.H. de; Leer, J.W.H.; Corver, R.

    1997-01-01

    Due to 1996 legislation in the Netherlands, every health care facility should have a quality assurance program. Because it is difficult to measure the quality of the product of care, a choice is made to focus on the process of care. For this purpose PACE was founded. (PACE is a Dutch acronym for Project ACcreditation) with as founding members: Public Health Insurance Council, TNO health research, 4 university hospitals and 4 large general hospitals. For in total 19 services and disciplines quality assurance standards where developed by groups in six of the hospitals. (author)

  1. A quality assurance initiative for commercial-scale production in high-throughput cryopreservation of blue catfish sperm.

    Science.gov (United States)

    Hu, E; Liao, T W; Tiersch, T R

    2013-10-01

    Cryopreservation of fish sperm has been studied for decades at a laboratory (research) scale. However, high-throughput cryopreservation of fish sperm has recently been developed to enable industrial-scale production. This study treated blue catfish (Ictalurus furcatus) sperm high-throughput cryopreservation as a manufacturing production line and initiated quality assurance plan development. The main objectives were to identify: (1) the main production quality characteristics; (2) the process features for quality assurance; (3) the internal quality characteristics and their specification designs; (4) the quality control and process capability evaluation methods, and (5) the directions for further improvements and applications. The essential product quality characteristics were identified as fertility-related characteristics. Specification design which established the tolerance levels according to demand and process constraints was performed based on these quality characteristics. Meanwhile, to ensure integrity throughout the process, internal quality characteristics (characteristics at each quality control point within process) that could affect fertility-related quality characteristics were defined with specifications. Due to the process feature of 100% inspection (quality inspection of every fish), a specific calculation method, use of cumulative sum (CUSUM) control charts, was applied to monitor each quality characteristic. An index of overall process evaluation, process capacity, was analyzed based on in-control process and the designed specifications, which further integrates the quality assurance plan. With the established quality assurance plan, the process could operate stably and quality of products would be reliable. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Quality assurance programme of Temelin nuclear power plant

    International Nuclear Information System (INIS)

    Eybl, J.; Nowak, O.

    1988-01-01

    The fundamental principle of the system of quality assurance in Czechoslovak nuclear power is quality assurance at all stages of the construction and operation of nuclear power plants and the grading fo measures taken, this in dependence on the impact on nuclear safety of the respective nuclear installation or its part. The system has been made fully operational during the construction of nuclear power plants in Temelin and Mochovce. State surveillance is executed by the Czechoslovak Atomic Energy Commission, and the Czech and Slovak Offices for Work Safety. Briefly discussed are the tasks of the building subcontractor of the Temelin nuclear power plant with regard to the programme of quality assurance as well as the results of the solution of the respective research tasks. The programme of quality assurance classifies the selected sections of the structure of a nuclear power plant into three safety categories. No part of the structure is classified into the first category, the second category includes, e.g., the reactor building, cooling tanks and diesel generator units, the third includes the reactor building and the building of auxiliary workshops. Attention is also paid to the problems of the qualification of personnel and to inspection activity. (Z.M.). 12 refs

  3. Quality assurance plan, Westinghouse Water Reactor Divisions

    Energy Technology Data Exchange (ETDEWEB)

    1976-03-01

    The Quality Assurance Program used by Westinghouse Nuclear Energy Systems Water Reactor Divisions is described. The purpose of the program is to assure that the design, materials, and workmanship on Nuclear Steam Supply System (NSSS) equipment meet applicable safety requirements, fulfill the requirements of the contracts with the applicants, and satisfy the applicable codes, standards, and regulatory requirements.

  4. Reflection on Quality Assurance System of Higher Vocational Education under Big Data Era

    Directory of Open Access Journals (Sweden)

    Jiang Xinlan

    2015-01-01

    Full Text Available Big data has the features like Volume, Variety, Value and Velocity. Here come the new opportunities and challenges for construction of Chinese quality assurance system of higher vocational education under big data era. There are problems in current quality assurance system of higher vocational education, such as imperfect main body, non-formation of internally and externally incorporated quality assurance system, non-scientific security standard and insufficiency in security investment. The construction of higher vocational education under big data era requires a change in the idea of quality assurance system construction to realize the multiple main bodies and multiple layers development trend for educational quality assurance system, and strengthen the construction of information platform for quality assurance system.

  5. Quality assurance of human error modelling in a major probabilistic risk assessment programme

    International Nuclear Information System (INIS)

    Rycraft, H.S.

    1990-01-01

    A method of incorporating the consideration of operator error within a major PRA exercise is described along with the quality assurance procedures employed to ensure a quality product. The exercise was undertaken at the Sellafield Reprocessing Plant. (author)

  6. Quality Assurance of Joint Programmes. ENQA Workshop Report 19

    Science.gov (United States)

    Frederiks, Mark; Grifoll, Josep; Hiltunen, Kirsi; Hopbach, Achim

    2012-01-01

    In view of the Bologna ministerial conference to be held in April 2012 in Bucharest, ENQA organised a seminar in September 2011 on Quality Assurance of Joint Programmes in collaboration with the Austrian Accreditation Council (OAR). The purpose of this seminar was twofold: first, to analyse the experience already gained in quality assurance of…

  7. Quality assurance when documenting chemical hazards to health and environment

    International Nuclear Information System (INIS)

    Guttormsen, R.; Modahl, S.I.; Tufto, P.A.; Buset, H.

    1991-01-01

    In a joint project between The Norwegian Petroleum Directorate (NPD), the State Pollution Control Agency (SFT) and Conoco Norway Inc. (CNI) we have evaluated the use of quality assurance principles in connection with development and distribution of information about chemicals. Assuring quality of the documentation is first of all depending on: the work in international organizations; the content of national and international guidelines and criteria documents; the use of product registers; activities in manufacturers' organizations; the role of importers and agents. These are aspects which have been evaluated. Recommendations are given in this paper concerning: definition of responsibilities in regulations, standards and guidelines; feedback of experience and coordination through international work; application of quality assurance principles in the use of information technology in international organizations and in manufacturers' organizations; use of quality assurance principles in validation of data

  8. Technical quality assurance in conventional radiography by X-ray assistants

    International Nuclear Information System (INIS)

    Juran, R.; Buehler, G.; Schmidt, D.

    1989-01-01

    Without the X-ray assistant, regularly involved in everyday practice, technical quality assurance can hardly be accomplished. Therefore a model for the organization of quality assurance was developed and tested in practice. It implies accountable technical checks by the technician, that are controlled by a quality supervisor, and are subsequently evaluated by the radiation physics department. This positively influences quality consciousness of the radiographers and therefore the quality itself. (author)

  9. Performance of the Lot Quality Assurance Sampling Method Compared to Surveillance for Identifying Inadequately-performing Areas in Matlab, Bangladesh

    OpenAIRE

    Bhuiya, Abbas; Hanifi, S.M.A.; Roy, Nikhil; Streatfield, P. Kim

    2007-01-01

    This paper compared the performance of the lot quality assurance sampling (LQAS) method in identifying inadequately-performing health work-areas with that of using health and demographic surveillance system (HDSS) data and examined the feasibility of applying the method by field-level programme supervisors. The study was carried out in Matlab, the field site of ICDDR,B, where a HDSS has been in place for over 30 years. The LQAS method was applied in 57 work-areas of community health workers i...

  10. Printed Circuit Board Quality Assurance

    Science.gov (United States)

    Sood, Bhanu

    2016-01-01

    PCB Assurance Summary: PCB assurance actives are informed by risk in context of the Project. Lessons are being applied across Projects for continuous improvements. Newer component technologies, smaller/high pitch devices: tighter and more demanding PCB designs: Identifying new research areas. New materials, designs, structures and test methods.

  11. 10 CFR 71.105 - Quality assurance program.

    Science.gov (United States)

    2010-01-01

    ... which functional compliance can be demonstrated by inspection or test; and (5) The quality history and... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance program. 71.105 Section 71.105 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) PACKAGING AND TRANSPORTATION OF RADIOACTIVE MATERIAL Quality...

  12. 'The use of technical specialists in quality assurance audits'

    International Nuclear Information System (INIS)

    Higgins, T.J.; Diaz, M.R.

    1993-01-01

    This paper provides a nontechnical discussion of the use of Technical Specialists in quality assurance audits by the Office of Civilian Radioactive Waste Management's Office of Quality Assurance. The purpose is to describe one successful solution to the problem that arises when a quality assurance organization is responsible for conducting audits of many, diverse, highly technical activities. The solution is the conduct of audits that combine both horizontal and vertical sample selection strategies and which employ Technical Specialists in the vertical portion of the audit. The Technical Specialist is paired with a programmatic auditor who perform as a dedicated team in their conduct of the audit. This paper focuses on the Technical Specialist

  13. National waste terminal storage program. Supplementary quality-assurance requirements

    International Nuclear Information System (INIS)

    Garland, D.L.

    1980-01-01

    The basic Quality Assurance Program Requirements standard for the National Waste Terminal Storage Program has been developed primarily for nuclear reactors and other fairly well established nuclear facilities. In the case of waste isolation, however, there are many ongoing investigations for which quality assurance practices and requirements have not been well defined. This paper points out these problems which require supplementary requirements. Briefly these are: (1) the language barrier, that is geologists and scientists are not familiar with quality assurance (QA) terminology; (2) earth sciences deal with materials that cannot be characterized as easily as metals or other materials that are reasonably homogeneous; (3) development and control of mathematical models and associated computer programs; (4) research and development

  14. Quality assurance programme and quality control

    International Nuclear Information System (INIS)

    Alvarez de Buergo, L.

    1979-01-01

    The paper analyses the requirements for the quality assurance and control in nuclear power plant projects which are needed to achieve safe, reliable and economic plants. The author describes the structure for the establishment of a nuclear programme at the national level and the participation of the different bodies involved in a nuclear power plant project. The paper ends with the study of a specific case in Spain. (NEA) [fr

  15. Quality Assurance Program Plan for TRUPACT-II Gas Generation Test Program

    International Nuclear Information System (INIS)

    2002-01-01

    The Gas Generation Test Program (GGTP), referred to as the Program, is designed to establish the concentration of flammable gases and/or gas generation rates in a test category waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II). The phrase 'gas generationtesting' shall refer to any activity that establishes the flammable gas concentration or the flammable gas generation rate. This includes, but is not limited to, measurements performed directly on waste containers or during tests performed on waste containers. This Quality Assurance Program Plan (QAPP) documents the quality assurance (QA) and quality control (QC) requirements that apply to the Program. The TRUPACT-II requirements and technical bases for allowable flammable gas concentration and gas generation rates are described in the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC).

  16. Effluent monitoring Quality Assurance Project Plan for radioactive airborne emissions data. Revision 2

    International Nuclear Information System (INIS)

    Frazier, T.P.

    1995-12-01

    This Quality Assurance Project Plan addresses the quality assurance requirements for compiling Hanford Site radioactive airborne emissions data. These data will be reported to the U.S. Environmental Protection Agency, the US Department of Energy, and the Washington State Department of Health. Effluent Monitoring performs compliance assessments on radioactive airborne sampling and monitoring systems. This Quality Assurance Project Plan is prepared in compliance with interim guidelines and specifications. Topics include: project description; project organization and management; quality assurance objectives; sampling procedures; sample custody; calibration procedures; analytical procedures; monitoring and reporting criteria; data reduction, verification, and reporting; internal quality control; performance and system audits; corrective actions; and quality assurance reports

  17. MRI quality assurance using the ACR phantom in a multi-unit imaging center

    International Nuclear Information System (INIS)

    Ihalainen, Toni M.; Kuusela, Linda J.; Savolainen, Sauli E.; Loennroth, Nadja T.; Peltonen, Juha I.; Uusi-Simola, Jouni K.; Timonen, Marjut H.; Sipilae, Outi E.

    2011-01-01

    Background. Magnetic resonance imaging (MRI) instrumentation is vulnerable to technical and image quality problems, and quality assurance is essential. In the studied regional imaging center the long-term quality assurance has been based on MagNET phantom measurements. American College of Radiology (ACR) has an accreditation program including a standardized image quality measurement protocol and phantom. The ACR protocol includes recommended acceptance criteria for clinical sequences and thus provides possibility to assess the clinical relevance of quality assurance. The purpose of this study was to test the ACR MRI phantom in quality assurance of a multi-unit imaging center. Material and methods. The imaging center operates 11 MRI systems of three major manufacturers with field strengths of 3.0 T, 1.5 T and 1.0 T. Images of the ACR phantom were acquired using a head coil following the ACR scanning instructions. Both ACR T1- and T2-weighted sequences as well as T1- and T2-weighted brain sequences in clinical use at each site were acquired. Measurements were performed twice. The images were analyzed and the results were compared with the ACR acceptance levels. Results. The acquisition procedure with the ACR phantom was faster than with the MagNET phantoms. On the first and second measurement rounds 91% and 73% of the systems passed the ACR test. Measured slice thickness accuracies were not within the acceptance limits in site T2 sequences. Differences in the high contrast spatial resolution between the ACR and the site sequences were observed. In 3.0 T systems the image intensity uniformity was slightly lower than the ACR acceptance limit. Conclusion. The ACR method was feasible in quality assurance of a multi-unit imaging center and the ACR protocol could replace the MagNET phantom tests. An automatic analysis of the images will further improve cost-effectiveness and objectiveness of the ACR protocol

  18. Nevada Nuclear Waste Storage Investigations Quality-Assurance Program Plan: management and overview

    International Nuclear Information System (INIS)

    1981-10-01

    This Quality Assurance Program Plan (QAPP) defines the quality assurance program in effect for those activities of the Nevada Nuclear Waste Storage (NNWSI) that are directly controlled by: DOE/NV, the Technical Overview Contractor, and the Quality Assurance Overview Contractor. It is intended as a supplement to the NNWSI-QAP

  19. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    International Nuclear Information System (INIS)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site

  20. Quality assurance in a large research and development laboratory

    International Nuclear Information System (INIS)

    Neill, F.H.

    1980-01-01

    Developing a quality assurance program for a large research and development laboratory provided a unique opportunity for innovative planning. The quality assurance program that emerged has been tailored to meet the requirements of several sponsoring organizations and contains the flexibility for experimental programs ranging from large engineering-scale development projects to bench-scale basic research programs

  1. Quality Assurance Program Plan for radionuclide airborne emissions monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Vance, L.M.

    1993-07-01

    This Quality Assurance Program Plan (QAPP) describes the quality assurance requirements and responsibilities for radioactive airborne emissions measurements activities from regulated stacks are controlled at the Hanford Site. Detailed monitoring requirements apply to stacks exceeding 1% of the standard of 10 mrem annual effective dose equivalent to the maximally exposed individual from operations of the Hanford Site.

  2. Quality assurance in digital dental imaging: a systematic review.

    Science.gov (United States)

    Metsälä, Eija; Henner, Anja; Ekholm, Marja

    2014-07-01

    Doses induced by individual dental examinations are low. However, dental radiography accounts for nearly one third of the total number of radiological examinations in the European Union. Therefore, special attention is needed with regard to radiation protection. In order to lower patient doses, the staff performing dental examinations must have competence in imaging as well as in radiation protection issues. This paper presents a systematic review about the core competencies needed by the healthcare staff in performing digital dental radiological imaging quality assurance. The following databases were searched: Pubmed, Cinahl, Pro Quest and IEEXplore digital library. Also volumes of some dental imaging journals and doctoral theses of the Finnish universities educating dentists were searched. The search was performed using both MeSH terms and keywords using the option 'search all text'. The original keywords were: dental imaging, digital, x-ray, panoramic, quality, assurance, competence, competency, skills, knowledge, radiographer, radiologist technician, dentist, oral hygienist, radiation protection and their Finnish synonyms. Core competencies needed by the healthcare staff performing digital dental radiological imaging quality assurance described in the selected studies were: management of dental imaging equipment, competence in image quality and factors associated with it, dose optimization and quality assurance. In the future there will be higher doses in dental imaging due to increasing use of CBCT and digital imaging. The staff performing dental imaging must have competence in dental imaging quality assurance issues found in this review. They also have to practice ethical radiation safety culture in clinical practice.

  3. Effect of technology on quality assurance

    International Nuclear Information System (INIS)

    Purvis, E.E. III

    1984-01-01

    Optimizing Quality Assurance activities by taking advantage of technological improvements is an issue directly related to overall product cost, quality, and delivery schedules. Use of automated tooling and numerical control have reduced manufacturing cycle time and thereby enabled better response to changing consumer tastes and market demand. Non-nuclear industries are using computer-aided technology for in-process inspection and final product acceptance. Non-destructive examination can also be performed real-time, on the production line. The challenge faced by the nuclear industry is to make the best use of new and emerging technology while satisfying compliance requirements. Currently, use of new methods is hampered by uncertainty about the affect on regulatory issues. Ways of using the technology have been developed for commercial applications without consideration of nuclear requirements

  4. APPROACH TO QUALITY ASSURANCE IN HIGHER EDUCATION

    Directory of Open Access Journals (Sweden)

    Zora Arsovski

    2007-03-01

    Full Text Available Quality assurance in higher education is streamed in two interconnected concepts: (1 quality management according to ISO 9000 and (2 Bologna process. In this paper both concepts are presented, with point on internal state and term plan activities for quality improvement in higher education in Serbia.

  5. Quality assurance of the bentonite material

    International Nuclear Information System (INIS)

    Ahonen, L.; Korkeakoski, P.; Tiljander, M.; Kivikoski, H.; Laaksonen, R.

    2008-05-01

    This report describes a quality assurance chain for the bentonite material acquisition for a nuclear waste disposal repository. Chemical, mineralogical and geotechnical methods, which may be applied in quality control of bentonite are shortly reviewed. As a case study, many of the presented control studies were performed for six different bentonite samples. Chemical analysis is a very reliable research method to control material homogeneity, because the accuracy and repeatability of the study method is extremely good. Accurate mineralogical study of bentonite is a complicated task. X-ray diffractometry is the best method to identify smectite minerals, but quantitative analysis of smectite content remains uncertain. To obtain a better quantitative analysis, development of techniques based on automatic image analysis of SEM images is proposed. General characteristics of bentonite can be obtained by rapid indicator tests, which can be done on the place of reception. These tests are methylene blue test giving information on the cation exchange capacity, swelling index and determination of water absorption. Different methods were used in the determination of cation exchange capacity (CEC) of bentonite. The results indicated differences both between methodologies and between replicate determinations for the same material and method. Additional work should be done to improve the reliability and reproducibility of the methodology. Bentonite contains water in different modes. Thus, different determination methods are used in bentonite studies and they give somewhat dissimilar results. Clay research use frequently the so-called consistency tests (liquid limit, plastic limit and plasticity index). This study method does, however, not seem to be very practical in quality control of bentonite. Therefore, only the determination of liquid limit with fall-cone method is recommended for quality control. (orig.)

  6. University Administrators' Conceptions of Quality and Approaches to Quality Assurance

    Science.gov (United States)

    Goff, Lori

    2017-01-01

    As the quality of university education garners increasingly more interest in both the public and in the literature, and as quality assurance (QA) processes are developed and implemented within universities around the world, it is important to carefully consider what is meant by the term quality. This study attempts to add to the literature…

  7. A Study on the Software Quality Assurance Plan

    International Nuclear Information System (INIS)

    Kim, Hyun Tae

    2006-01-01

    On 25 August 2006, the CMMI V1.2 (Capability Maturity Model Integration Version 1.2) was released with the new title CMMI-DEV (CMMI for Development) which supersedes the CMMI-SE/SW (CMMI for systems engineering and software engineering) V1.1. This study discusses the application of IEEE Std 730-2002, IEEE Standard for Software Quality Assurance Plans, for the implementation of the Process and Product Quality Assurance (PPQA) process area (PA) of the CMMI-DEV

  8. Quality assurance programme for the LVR-15 nuclear research reactor

    International Nuclear Information System (INIS)

    1995-03-01

    The document specifies all aspects of the quality assurance programme for the LVR-15 nuclear research reactor. The programme addresses the organization and responsibilities, basic quality assurance activities, and identification of management, planning, and working documents necessary to implement the programme. (P.A.)

  9. Education for All in South Africa: Developing a National System for Quality Assurance.

    Science.gov (United States)

    Smith, William J.; Ngoma-Maema, Wendy Yolisa

    2003-01-01

    Draws on international research, policy, and practice relevant to quality assurance systems to analyze the development of a national framework for educational quality assurance in South Africa. Describes an emerging framework for quality assurance that encompasses evaluation of student achievement, quality audits and reviews, program and service…

  10. Quality control and quality assurance in individual monitoring of ionising radiations

    International Nuclear Information System (INIS)

    Dutt, J.C.; Lindborg, L.

    1994-01-01

    This paper describes the programmes and approaches that are to be considered in developing and introducing quality assurance and quality control procedures in individual monitoring services. Quality assurance and quality control in individual monitoring services are essential to maintain quality and are of increasing importance in order to meet the requirements of national regulations and international standards and guidelines. It is recommended here that all organisations offering individual monitoring services should run their services based on the principles of Quality System as given in the European Standard EN45001 and maintain a property resources QA/QC programme as an integral part of their operations. All aspects of QA/QC in individual monitoring services starting from the initial selection, installation, calibration, and operation to the final products including dose reporting, dose record keeping, dealing with customers' complaints and product liability issues have been discussed. (Author)

  11. Quality assurance in diabetic retinal screening in South Africa | Cook ...

    African Journals Online (AJOL)

    ... external quality assurance (EQA) on graders registered in the Ophthalmological Society of South Africa DR screening programme. Methods. Graders registered on the South African (SA) Diabetic Register website were invited to participate in the study. The Scottish EQA software system was used to enable on-line grading ...

  12. Quality Assurance in University Guidance Services

    Science.gov (United States)

    Simon, Alexandra

    2014-01-01

    In Europe there is no common quality assurance framework for the delivery of guidance in higher education. Using a case study approach in four university career guidance services in England, France and Spain, this article aims to study how quality is implemented in university career guidance services in terms of strategy, standards and models,…

  13. Quality assurance when refitting - SUSAN example

    International Nuclear Information System (INIS)

    Gautier, R.

    1992-01-01

    The most important points of quality assurance for the realisation of the SUSAN project (special independent system for the dissipation of post-decay heat) at the Muehleberg nuclear power station are discussed in this article. The periodic controls and function tests which have been performed since August 1989, confirm the quality of the products used

  14. 10 CFR 72.144 - Quality assurance program.

    Science.gov (United States)

    2010-01-01

    ... quality history and degree of standardization of the item. (d) The licensee, applicant for a license... 10 Energy 2 2010-01-01 2010-01-01 false Quality assurance program. 72.144 Section 72.144 Energy... NUCLEAR FUEL, HIGH-LEVEL RADIOACTIVE WASTE, AND REACTOR-RELATED GREATER THAN CLASS C WASTE Quality...

  15. Factors affecting the adoption of quality assurance technologies in healthcare.

    Science.gov (United States)

    Storey, John

    2013-01-01

    In the light of public concern and of strong policy emphasis on quality and safety in the nursing care of patients in hospital settings, this paper aims to focus on the factors affecting the adoption of innovative quality assurance technologies. Two sets of complementary literature were mined for key themes. Next, new empirical insights were sought. Data gathering was conducted in three phases. The first involved contact with NHS Technology Hubs and other institutions which had insights into leading centres in quality assurance technologies. The second phase was a series of telephone interviews with lead nurses in those hospitals which were identified in the first phase as comprising the leading centres. The third phase comprised a series of face to face interviews with innovators and adopters of healthcare quality assurance technologies in five hospital trusts. There were three main sets of findings. First, despite the strong policy push and the templates established at national level, there were significant variations in the nature and robustness of the quality assurance toolkits that were developed, adapted and adopted. Second, in most of the adopting cases there were important obstacles to the full adoption of the toolkits that were designed. Third, the extent and nature of the ambition of the developers varied dramatically - some wished to see their work impacting widely across the health service; others had a number of different reasons for wanting to restrict the impact of their work. The general concerns about front-line care and the various inquiries into care quality failures emphasise the need for improved and consistent care quality assurance methodologies and practice. The technology adoption literature gives only partial insight into the nature of the challenges; this paper offers specific insights into the factors inhibiting the full adoption of quality assurance technologies in ward-based care.

  16. Developing and Implementing a Quality Assurance Strategy for Electroconvulsive Therapy.

    Science.gov (United States)

    Hollingsworth, Jessa; Baliko, Beverly; McKinney, Selina; Rosenquist, Peter

    2018-04-17

    The literature provides scant guidance in effective quality assurance strategies concerning the use of electroconvulsive therapy (ECT) for the treatment of psychiatric conditions. Numerous guidelines are published that provide guidance in the delivery of care; however, little has been done to determine how a program or facility might ensure compliance to best practice for safety, tolerability, and efficacy in performing ECT. The objective of this project was to create a quality assurance strategy specific to ECT. Determining standards for quality care and clarifying facility policy were key outcomes in establishing an effective quality assurance strategy. An audit tool was developed utilizing quality criteria derived from a systematic review of ECT practice guidelines, peer review, and facility policy. All ECT procedures occurring over a 2-month period of May to June 2017 were retrospectively audited and compared against target compliance rates set for the facility's ECT program. Facility policy was adapted to reflect quality standards, and audit findings were used to inform possible practice change initiatives, were used to create benchmarks for continuous quality monitoring, and were integrated into regular hospital quality meetings. Clarification on standards of care and the use of clinical auditing in ECT was an effective starting point in the development of a quality assurance strategy. Audit findings were successfully integrated into the hospital's overall quality program, and recognition of practice compliance informed areas for future quality development and policy revision in this small community-based hospital in the southeastern United States. This project sets the foundation for a quality assurance strategy that can be used to help monitor procedural safety and guide future improvement efforts in delivering ECT. Although it is just the first step in creating meaningful quality improvement, setting clear standards and identifying areas of greatest

  17. Electronic laboratory quality assurance program: A method of enhancing the prosthodontic curriculum and addressing accreditation standards.

    Science.gov (United States)

    Moghadam, Marjan; Jahangiri, Leila

    2015-08-01

    An electronic quality assurance (eQA) program was developed to replace a paper-based system and to address standards introduced by the Commission on Dental Accreditation (CODA) and to improve educational outcomes. This eQA program provides feedback to predoctoral dental students on prosthodontic laboratory steps at New York University College of Dentistry. The purpose of this study was to compare the eQA program of performing laboratory quality assurance with the former paper-based format. Fourth-year predoctoral dental students (n=334) who experienced both the paper-based and the electronic version of the quality assurance program were surveyed about their experiences. Additionally, data extracted from the eQA program were analyzed to identify areas of weakness in the curriculum. The study findings revealed that 73.8% of the students preferred the eQA program to the paper-based version. The average number of treatments that did not pass quality assurance standards was 119.5 per month. This indicated a 6.34% laboratory failure rate. Further analysis of these data revealed that 62.1% of the errors were related to fixed prosthodontic treatment, 27.9% to partial removable dental prostheses, and 10% to complete removable dental prostheses in the first 18 months of program implementation. The eQA program was favored by dental students who have experienced both electronic and paper-based versions of the system. Error type analysis can yield the ability to create customized faculty standardization sessions and refine the didactic and clinical teaching of the predoctoral students. This program was also able to link patient care activity with the student's laboratory activities, thus addressing the latest requirements of the CODA regarding the competence of graduates in evaluating laboratory work related to their patient care. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  18. Quality assurance during preoperational testing and during startup operation

    International Nuclear Information System (INIS)

    Eisele, H.; Meyer, F.A.

    1980-01-01

    Rules and guidelines for the quality assurance. Quality assurance in the course of preoperational testing and the startup period: preoperational testing; hot functional test I; hot functional test II; initial making critical and zero power physics testing; power range testing. Startup documents: startup program; startup instructions; startup data sheet; startup sequence outlines; final startup reports. Advisory safety committee for nuclear startup. (orig./RW)

  19. Performance Assesment of Bauchi Polytechnics and Technical Colleges Using Quality Assurance Indicators in Nigeria Qualification Framework

    Directory of Open Access Journals (Sweden)

    Idris Adamu

    2016-07-01

    Full Text Available Technical and Vocational Education emphases skill acquisition, Quality Assurance in vocational education is concept that is concerned with high performance involved activities with vocational education such as teaching, learning, infrastructures, student’s behavior and entire academic process. Good quality education is very necessary in the total development of staff and students which ensures proper development, job prospects and the realization of academic goals and objects. Enhanced and sustained to ensure accountability and improve performance. Higher educational institutions in Nigeria continue to experience carelessly attitude about the use of Quality Assurance to understand the risk they are exposed to poor standard. To address these issues, the study embarked upon to determine the level of performance and difference usability of Quality Assurance in Polytechnics and Technical Colleges in Bauchi state. Quantitative method technique was employed using survey questionnaires, 60 staff both senior and junior within these institutions were selected and a questionnaire distributed for their responses. The data were analysed using SPSS software. The result reveals that Federal Polytechnic Bauchi and State Polytechnic Bauchi has high level of Performance about Quality Assurance indicators while College of Education Azare has medium level of Performance. College of education Azare has highest mean rank of 29.87 and percentage of 31.8% obtained from the output result indicated that it has high usability to Quality Assurance, followed by Federal Polytechnic Bauchi with medium usability then State Polytechnic Bauchi has low usability to Quality Assurance. The study concluded by Quality Assurance Unit be made aware to each institution staff to enable recognize the benefits of it. Federal government should give more funding and employ staff to cater the need of Quality Assurance Unit in every institution so that it will help the students to develop

  20. Core components of a comprehensive quality assurance program in anatomic pathology.

    Science.gov (United States)

    Nakhleh, Raouf E

    2009-11-01

    In this article the core components of a comprehensive quality assurance and improvement plan are outlined. Quality anatomic pathology work comes with focus on accurate, timely, and complete reports. A commitment to continuous quality improvement and a systems approach with a persistent effort helps to achieve this end. Departments should have a quality assurance and improvement plan that includes a risk assessment of real and potential problems facing the laboratory. The plan should also list the individuals responsible for carrying out the program with adequate resources, a defined timetable, and annual assessment for progress and future directions. Quality assurance monitors should address regulatory requirements and be organized by laboratory division (surgical pathology, cytology, etc) as well as 5 segments (preanalytic, analytic, postanalytic phases of the test cycle, turn-around-time, and customer satisfaction). Quality assurance data can also be used to evaluate individual pathologists using multiple parameters with peer group comparison.