WorldWideScience

Sample records for pyrophosphate myocardial scanning

  1. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M. (Toronto Hospital, Ontario (Canada))

    1989-12-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.

  2. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    International Nuclear Information System (INIS)

    Cheng, D.C.; Chung, F.; Burns, R.J.; Houston, P.L.; Feindel, C.M.

    1989-01-01

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic, preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction

  3. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    International Nuclear Information System (INIS)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-01-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve

  4. Significance of calcific valvular heart disease in /sup 99m/Tc pyrophosphate myocardial infarction scanning: radiographic, scintigraphic, and pathological correlation

    Energy Technology Data Exchange (ETDEWEB)

    Jengo, J.A.; Mena, I.; Joe, S.H.; Criley, J.M.

    1977-08-01

    Technetium-99m pyrophosphate (PP/sub i/) is currently considered the best scanning agent for the diagnosis of acute myocardial infarction. False-positive scans have been reported in association with unstable angina, alcoholic cardiomyopathy, and ventricular aneurysms. In this study, 86 percent of patients (12/14) with either calcific aortic or mitral valvular heart disease had positive PP/sub i/ cardiac scintiscans and the location of the PP/sub i/ uptake was limited to the calcific valve in all (9/9) of the patients who underwent valve replacement surgery. Six patients with valvular disease without radiologic evidence of calcium had negative PP/sub i/ heart images. Three of these patients had surgical valve replacement, and in none was there increased uptake in the resected valve. Seventy-five percent of the patients with calcified aortic valves had localization of the PP/sub i/ activity to the area of the aortic valve, whereas 50 percent of the patients with calcified mitral valves showed a diffuse pattern of uptake on the cardiac image. In vitro demonstration of increased radioactivity in surgically removed cardiac valves warrants the conclusion that Tc-99m PP/sub i/ is taken up by calcified heart valves. We conclude that while PP/sub i/ heart scanning is a sensitive indicator of acute myocardial infarction, false-positive scans can occur in the presence of calcific valvular disease, due to localization of PP/sub i/ in the calcified portion of the valve.

  5. Pyrophosphate scan of the temporarily ischemized dog myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Veverkova, O.

    1981-12-01

    In 9 dogs a transient myocardial ischemia was provoked using complete occlusion of the ramus interventricularis anterior of the left coronary artery. The occlusion was removed after 5, 10 or 15 min. Four hrs after removal of the occlusion a scan of the myocardium was carried out using sup(99m)Tc-labelled pyrophosphate. In 7 out of 9 dogs under study the scan was markedly positive, in 2 dogs negative. ECG demonstrated ischemic changes practically in all dogs; the changes became normal after removal of the occlusion, namely in 5 to 35 min. The histological examination of the tissue demonstrated in all 9 dogs only a slight impairment of the myocardium.

  6. Technetium-99m-pyrophosphate myocardial imaging in unstable angina

    International Nuclear Information System (INIS)

    Willerson, J.T.; Parkey, R.W.; Lewis, S.E.; Buja, L.M.; Bonte, F.J.

    1980-01-01

    The authors have found that approximately one third of patients with the syndrome of unstable angina pectoris have abnormal 99mTc-pyrophosphate myocardial scintigrams even in the absence of abnormal enzymes and electrocardiographic confirmation of the presence of acute myocardial necrosis. Thus, 99mTc-pyrophosphate myocardial imaging technique appears to represent a sensitive means to detect acute multicellular injury associated with the clinical syndrome of unstable angina pectoris even when cardiac enzymes are normal and the electrocardiogram does not definitively document the presence of acute myocardial necrosis. (Auth.)

  7. Detection of unstable angina by /sup 99m/technetium pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Abdulla, A.M.; Canedo, M.I.; Cortez, B.C.; McGinnis, K.D.; Wilhelm, S.K.

    1976-01-01

    /sup 99m/Technetium stannous pyrophosphate has been shown to accumulate in acutely infarcted myocardium. To determine if the isotope is also taken up by severely ischemic, but not necrotic myocardium, we performed myocardial scintigraphic studies in 17 patients with chest pains. Seven of the patients satisfied conventional clinical, electrocardiographic, and laboratory criteria for the diagnosis of unstable angina and showed no electrocardiographic or enzymatic evidence of myocardial necrosis. Five of these seven patients with unstable angina demonstrated abnormal localized patterns, and one showed a borderline picture. Myocardial scintiscans were normal in all of a control group of ten patients with stable angina. Thus, scanning with /sup 99m/technetium stannous pyrophosphate is shown to be of value in the objective demonstration of myocardial abnormality in unstable angina

  8. Scintigraphic diagnosis of acute nontransmural myocardial infarction using sup(99m)Tc-labelled pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Novak, J; Vizda, J; Kafka, P; Kubicek, J; Veverkova, O [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1980-04-01

    In 10 patients with acute non-transmural myocardial lesion, the heart muscle was examined by scintigraphy. The scan was negative in 4 patients, positive in 6. No obvious relationship was observed between the degree and character of sup(99m)Tc-pyrophosphate cumulation in the myocardial lesion and the results of other laboratory tests. The actual site of non-transmural lesion cannot be determined by scan. Although scintigraphy alone cannot decide whether a non-transmural necrosis or mere ischemic heart disease is involved, the method is a valuable addition to other diagnostic techniques presently in use.

  9. Clinical significance of technetium-99m stannous pyrophosphate myocardial scintigrams in patients with acute and old myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kanazawa, Ikuo; Eno, Shin; Takeuchi, Masaaki

    1987-08-01

    Seventy-five consecutive patients with acute (43) or old (32) myocardial infarction (AMI, OMI) have been examined by myocardial scintiscanning with technetium-99m stannous pyrophosphate (PYP). Using Parker's classification, the PYP scans were graded as positive in 56 % of the AMI patients; in restricting to the PYP scans obtained within the first 3 days after the onset, the positive rate was 86 %. Positive or negative PYP scans for the AMI patients were independent of maximum creatine phosphokinase and infarct site. For OMI patients, the PYP scans were positive in 41 %, with decreased left ventricular function being more common than those having negative PYP scans. In the group of positive scans, clinical manifestations tended to be remarkable, which were likely due to persistent cardiac ischemia during chronic stage. (Namekawa, K.).

  10. Prognosis of ischemic heart disease based on pyrophosphate scan of myocardium

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F [Karlova Univ., Hradec Kralove (Czechoslovakia). Lekarska Fakulta

    1982-11-01

    A brief survey is given of the present knowledge of the problems, based on literary data. Pyrophosphate myocardial scan is an important examination in establishing the diagnosis of acute myocardial infarction and some other myocardial diseases. Apart from this, it is of great importance in determining the prognosis. In the early phase of the disease, an apparently worse prognosis is found in patients with extensive lesion, and in those with an infarction intensively accumulating the radiopharmaceutical. In a certain number of infarctions, scintigraphic examination is positive over several months; usually the radiopharmaceutical disappears within two weeks. Patients with long-persisting positivity have a markedly worse prognosis. On the basis of early and late heart scan, it is thus possible to estimate the future fate of patients w+th ischemic heart disease. Large and long-persisting lesions serve as a warning for the physician.

  11. Scintigraphic visualization of myocardial infarcts in baboons using thallium-201 and technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Frick, M P; Ponto, R A; Pyle, R B; Yasmineh, W G; Loken, M K

    1978-01-01

    Four baboons with myocardial infarcts were evaluated using thallium-201 for myocardial imaging and /sup 99m/Tc pyrophosphate for infarct visualization. Scintiphotographic findings were compared with the size of myocardial infarcts calculated from measurements of the activity of MB isoenzymes of creatine kinase (CK-MB) in serum and in the myocardium at autopsy, as described by Sobel's method. Lack of thallium-201 accumulation was noted in left ventricular infarcts of 3 of the 4 baboons. These same areas localized /sup 99m/Tc pyrophosphate administered 24 to 30 h after infarction.

  12. Scintigraphic myocardial imaging with sup(99m)Tc-labelled pyrophosphate of experimentally produced cardiomyopathy in dogs

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Novak, J.; Vizda, J.; Kubicek, J.; Kafka, P.; Mazurova, Y.; Bradna, P.

    1981-12-01

    Scintigraphic examination of the myocardium using sup(99m)Tc-labelled pyrophosphate was carried out in 10 dogs with experimentally produced cardiomyopathy. This was brought by introvenous administration of high doses of adrenalin and theophylline. The scan was positive in 8 out of 10 dogs. Hot foci were very extensive. The degree of accumulation was however low (2+). Histological examination of the myocardium using the light microscope showed only scarcely distinguishable damage to the tissue without the presence of necrosis. ECG examinations were normal in all cases. By means of sup(99m)Tc-labelled pyrophosphate even very small myocardial disorders can thus be detected. This fact may be of clinical importance for an early diagnosis of heart lesions.

  13. Scan analysis in myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Ell, P J [Landesunfallkrankenhaus, Feldkirch (Austria). Inst. fuer Strahlenmedizin

    1976-08-01

    Myocardial scans with sup(99m)Tc-labelled phosphates are reported to be useful in the diagnosis of acute myocardial infarction. A retrospective survey of 205 patients referred for sup(99m)Tc-phophate bone scanning and with no evidence of recent heart disease revealed an occurrence of 10% of false positive images, that is to say, uptake of phosphate in non-infarcted mayocardium. These striking findings stress the need for critical assessment of the usefulness of this diagnostic technique.

  14. Sensitivity of {sup 99m}Tc-pyrophosphate scintigraphy in diagnosis of acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seong Hee; Park, Tai Que; Chae, Yoo Soon; Kim, Yang Sook [Maryknoll Hospital, Busan (Korea, Republic of)

    1991-01-15

    To assess the difference of the diagnostic sensitivity of {sup 99m}Tc-Pyrophosphate (PYP) myocardial scintigraphy in acute transmural infarction and acute subendocardial infarction, we analyzed 38 patients with a confirmed transmural infarct, 10 with a subendocardial infarct, 2 with old myocardial infarct, and 10 with other cardiovascular disease (2 unstable angina, 6 stable angina, 1 Prinzmetal angina, and 1 atrial fibrillation) according to Berman's criteria for scintigraphic assessment and then come to conclusion; When only focal myocardial uptake wa used as a criteria for positivity, the diagnostic sensitivity of {sup 99m}Tc-PYP scintigraphy in acute subendocardial myocardial infarction was only 40% (4/10) compared with 86.8% (33/38) of acute transmural myocardial infarction. There was no case that was interpreted as focal myocardial uptake in 2 old myocardial infarction and 10 other cardiovascular disease. The incidence of complication was higher in doughnut pattern of myocardial uptake 50% (3/6) than in non-doughnut focal patterns 19.4% (6/31). It is concluded that focal myocardial uptake is a sensitive indicator suggesting acute myocardial necrosis and that {sup 99m}Tc-PYP myocardial scintigraphy is a sensitive technique for diagnosing acute transmural myocardial infarction, but a insensitive method in acute subendocardial infarction, and that the doughnut pattern of myocardial uptake an provide clues to the patient's future course.

  15. Usefulness of scintigraphy with Tc-99m labelled pyrophosphate in the diagnosis of acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Zolna, J; Strzelecki, A; Bartoszewski, A; Kardaszewicz, P; Salamon, A; Waligorski, M

    1982-01-01

    In 32 patients with transmural myocardial infarction scintigraphy was done using technetium-99m pyrophosphate as a marker. The test was performed between 4 and 7 day after infarction onset. In the group of 18 patients with anterior wall infarction in 2 cases no cumulation of the radioisotope was observed while in 14 cases the absorption of pyro-phosphate estimated to correspond to grade 2 or 3 in Parkey's scoring system was observed. In the group of 14 patients with inferior wall infarction in 4 cases pyrophosphate was not absorbed or only in a small degree. In the remaining patients radioactivity absorption was estimated to correspond to Parkey's grades 2 or 3. In both groups the radioacti-vity was absorbed more intensely in cases with high creatine phosphoki-nase values.

  16. Myocardial scintigraphy using pyrophosphate-technetium 99m. 367 cases

    Energy Technology Data Exchange (ETDEWEB)

    Degeorges, M; Roucayrol, J C; Sol, C; Comet, M; Vassilopoulos, J [Hopital Cochin, 75 - Paris (France)

    1977-04-30

    Pyrophosphate-sup(99m)Tc injected intravenously, is almost invariably fixed in the infarcted zone in transmural infarctions less than 8 days old. Fixation occurs in only 2/3 of cases of rudimentary infarction. The degree of fixation is more or less proportional to the size of the peak of creatine phosphokinase. After the 8th day following infarction, fixation is slight or nil. It is inconstant in pre-infarction syndrome or simple angina. This examination complements clinical, electrocardiographic and enzyme findings, in particular in the case of difficult diagnosis.

  17. Recognition of reversible and irreversible myocardial injury by technetium pyrophosphate extraction kinetics

    International Nuclear Information System (INIS)

    Silva, R.; Chen, Y.F.; Sell, T.L.; Lowe, J.E.; Jones, R.H.

    1987-01-01

    The need for a more accurate method of detecting episodes of myocardial ischemia during cardiac operations, particularly during the ischemic arrest interval, prompted us to investigate the usefulness of measuring the active extraction of technetium pyrophosphate in identifying and quantitating ischemic injury. Twenty-four adult mongrel dogs were subjected to cardiopulmonary bypass, and normothermic global ischemia was induced by cross-clamping the proximal aorta. Technetium pyrophosphate (1 mCi) was injected through a standard cardioplegia line with normal saline, simulating administration of cardioplegic solution, upon placement of the aortic cross-clamp (time 0), at 15, 30, 45, and 60 minutes of global ischemia, and with the onset and completion of ischemic contracture. Radioactive counts were recorded over the heart at 1 second intervals, and the extraction fraction and half-time of clearance were calculated. The extraction fraction increased from 0.22 at time 0 to 0.58 at 15 minutes, 0.82 at 30 minutes, 0.85 at 45 minutes, and 0.91 at 60 minutes. The halftime increased from a baseline of 114 seconds (time 0) to a maximum of 321 seconds at 60 minutes of ischemia. The onset and completion of ischemic contracture showed a return toward baseline of both the extraction fraction and halftime of clearance, with an extraction fraction of 0.44 and 0.46 and a halftime of 135 and 133 seconds, respectively. These data clearly show that reversible myocardial injury increased the extraction and reduced the clearance of technetium pyrophosphate and that the magnitude of change related to the extent of injury. The progression to irreversible myocardial injury decreased the active extraction of technetium pyrophosphate. This simple procedure for real-time documentation of myocardial injury promises to provide easily obtainable endpoints of injury for use during cardiac operations in humans

  18. Early estimation of acute myocardial infarct size soon after coronary reperfusion using emission computed tomography with technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Hashimoto, T.; Kambara, H.; Fudo, T.; Tamaki, S.; Nohara, R.; Takatsu, Y.; Hattori, R.; Tokunaga, S.; Kawai, C.

    1987-01-01

    Early appearance of positive findings on a technetium-99m pyrophosphate scan has been shown to be associated with the presence of a reperfused acute myocardial infarction (AMI). Early technetium-99m pyrophosphate imaging was performed by emission computed tomography to evaluate reperfusion and to test the feasibility of estimating infarct size soon after coronary reperfusion based on acute positive tomographic findings. Twenty-seven patients with transmural AMI who were treated with intracoronary urokinase infusion followed by percutaneous transluminal coronary angioplasty underwent pyrophosphate imaging 8.7 +/- 2.1 hours after the onset of AMI. None of the 8 patients in whom reperfusion was unsuccessful had acute positive findings. Of 19 patients in whom reperfusion was successful, 17 had acute positive findings (p less than 0.001). In these 17, tomographic infarct volumes were determined from reconstructed transaxial images. The threshold for areas of increased pyrophosphate uptake within the infarct was set at 60% of peak activity by the computerized edge-detection algorithm. The total number of pixels in all transaxial sections showing increased tracer uptake were added and multiplied by a size factor and 1.05 g/cm3 muscle to determine infarct volume. The correlations of tomographic infarct volumes with peak serum creatine kinase (CK) levels (r = 0.82) and with cumulative release of CK-MB isoenzyme (r = 0.89) were good. Moreover, the time to positive imaging was significantly shorter than that to peak CK level (8.5 +/- 2.3 vs 10.4 +/- 2.2 hours, p less than 0.005)

  19. Technetium-99m--pyrophosphate bone scans in hyperparathyroidism

    International Nuclear Information System (INIS)

    Wiegmann, T.; Rosenthall, L.; Kaye, M.

    1977-01-01

    Most patients with primary hyperparathyroidism have normal 5-hr bone-to-soft-tissue ratios for /sup 99m/Tc-pyrophosphate. In contrast, all five patients with advanced secondary hyperparathyroidism in this study showed significant (p less than 0.001) increases of bone uptake. In the early period after parathyroidectomy, there was no quantitative or qualitative change in uptake. A limited decrease of bone uptake was observed only after prolonged periods of observation. In itself, parathyroid activity seems to have little direct influence on bone uptake of /sup 99m/Tc-pyrophosphate

  20. Clinical usefulness of technetium-99m pyrophosphate and Tl-201 myocardial imaging for the estimation of myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Akio; Sato, Akihiko; Miyakoda, Hiroyuki; Watanabe, Toshiya; Itatsu, Hidetaka; Ueda, Osamu; Sakurai, Kuniteru; Kawai, Naoki; Sotobata, Iwao

    1985-04-01

    A correlative study was performed between the infarct size estimated by either technetium-99 pyrophosphate (Tc-PYP) or Tl-201 myocardial imaging, and the cumulative total creatinine phosphokinase activity (..sigma..CPK) or left ventricular ejection fraction (LVEF) in 40 patients with acute myocardial infarction. Tc-PYP infarct area (TcIA) and mean Tl-201 uptake ratio (MUR) were calculated as indices of myocardial infarct size. LVEF was evaluated by first pass method using Tc-PYP in the acute phase of myocardial infraction. In 23 patients with anterior myocardial infarction, a significant correlation was shown between either TcIA or anterior-wall MUR and ..sigma..CPK (r=0.81 and r=-0.69, respectively) and also between either TcIA or anterior-wall MUR and LVEF (r=-0.84 and r=0.80, respectively). In 17 patients with inferior myocardial infarction without additional involvement of right ventricular wall, inferior-wall MUR correlated with ..sigma..CPK (r=-0.74). No statically significant correlation was shown between TcIA and ..sigma..CPK, and also between either TcIA or inferior-wall MUR and LVEF. In conclusion, the infarct size estimated with Tc-PYP or Tl-201 myocardial imaging could be a useful clinical indicator of the severity of acute myocardial infarction especially in anterior wall. (author).

  1. Importance of scintigraphy of the myocardium with Csup(99m)-Tc-pyrophosphate in the diagnosis of myocardial ischemia

    Energy Technology Data Exchange (ETDEWEB)

    Botnar' , V I; Dvoskina, I S [Inst. Kardiologii Vsesoyuznogo Kardiologicheskogo Nauchnogo Tsentra AN SSSR

    1983-10-01

    The following aspects of the method of scintigraphy of the myocardium with sup(99m)Tc-pyrophosphate as test sensitivity, possibility of estimating necrosis focus, prognostic importance of the method, scintigram dynamics in case of acute infarction, pyrophosphate accumulation in myocardial cells are considered. Advantages and prospects of the method for visualization of acute myocardium infarction focus and in cases of other pathological states are pointed out.

  2. sup(99m)Tc-pyrophosphate and /sup 201/Tl myocardial scintigrams in a patient with myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, M.; Nishimura, T.; Shimoto, Y.; Fuzioka, S.; Kobayashi, K. (Shimada City Hospital, Shizuoka (Japan))

    1981-09-01

    Myocardial necrosis in acute myocarditis was investigated by scintigraphy. sup(99m)Tc-pyrophosphate (PYP) and /sup 201/TI myocardial scintigrams were obtained on a patient with acute myocarditis due to mycoplasma infection. sup(99m)Tc-PYP myocardial scintigrams in the acute stage demonstrated grade 2+ findings, which remained until the chronic stage. /sup 201/TI myocardial scintigrams in the acute stage revealed impaired perfusion restricted to the posterolateral wall, and this decrease continued through the chronic stage. It was concluded that both of sup(99m)Tc-PYP and /sup 201/TI myocardial scintigrams can reveal abnormality of acute myocarditis.

  3. Tc-99m pyrophosphate scanning after ischemic exercise in McArdle's disease

    International Nuclear Information System (INIS)

    Uno, Hideaki; Kawano, Keizo; Yukawa, Susumu; Nomoto, Hiroshi

    1982-01-01

    In order to clarify the mechanism of muscle contracture induced by ischemic exercise in a patient with McArdle's disease, bone scanning with Tc-99m pyrophosphate was performed. The clinical diagnosis was established in the patient based on the biochemical examinations of skeletal muscle biopsy. Ischemic exercise was done initially on the left forearm and then 20 hours later on the right forearm. Two hours later, 15 mCi of Tc-99m pyrophosphate was infused through the left antecubital vein. Exactly 4 hours later, a conventional bone scanning was carried out. In the patient with McArdle's disease, muscle contracture developed in both forearms during the ischemic exercise. Conventional bone scanning showed increased Tc-99m pyrophosphate labeling of the right forearm muscles at 2 hours after ischemic exercise. However, increased labeling of the left forearm muscles was not found at 22 hours after ischemic exercise. In the control, no muscle contracture developed during ischemic exercise and bone scan showed no increase in Tc-99m pyrophosphate labeling in the antebrachial region. These findings suggest that the basis of muscle contracture appears to be an increased concentration of Ca in muscle cells due to a failure of sarcoplasmic reticulum to reaccumulate Ca at ischemic exercise. (author)

  4. Technetium-99m pyrophosphate myocardial scintigraphy in the diagnosis of acute rheumatic carditis

    International Nuclear Information System (INIS)

    Malhotra, A.; Radhakrishnan, S.; Reddy, K.S.; Gopinath, P.G.; Bhatia, M.L.

    1989-01-01

    Rheumatic fever (RF) and rheumatic heart disease (RHD) are major health problems in India. The most difficult decision to make in such a setting is whether a patient of acute rheumatic fever has acute rheumatic carditis or not. Physical signs such as a new cardiac murmur, cardiac enlargement, congestive cardiac failure although quoted as pointers to carditis are non-specific specially if the attack is superimposed on pre-existing RHD. Any investigation which will provide an answer to this problem would be very welcome. sup(99m)Tc pyrophosphate (Tc PYP) is a very sensitive indicator of myocardial necrosis in acute myocardial infarction. A study to determine the usefulness of this technique in diagnosis of rheumatic carditis in patients with unequivocal clinical evidence of myocarditis was undertaken. Results are reported. (author). 14 refs

  5. Sup(99m)Tc-Sn-pyrophosphate complex. A stable, lyophilized radiopharmaceutical for skeletal scanning

    Energy Technology Data Exchange (ETDEWEB)

    Cvoric, J; Jovanovic, V; Bzenic, J [Institut za Nuklearne Nauke Boris Kidric, Belgrade (Yugoslavia); Stefanovic, Lj; Selir, Z [Institute for Tuberculosis and Pectoral Diseases, Radioisotope Applications, Sremska Kamenica (Yugoslavia)

    1978-01-01

    After a systematic investigation of the different phosphate polymers, viz. hexametaphosphate, tripolyphosphate, meta- and diphosphonate, pyrophosphate (Na/sub 4/P/sub 2/O/sub 7/) was selected for sceletal scintigraphy. A procedure has been developed for obtaining a sup(99m)Tc-labelled Sn(II): PyP complex by addition of a sterile, apyrogenic pertechnetate solution from a sup(99m)Tc-generator to a lyophilized solution of Sn(II)-tetrasodium phosphate. ''Kit'' composition was determined on the basis of biodynamic data obtained when the Sn/pyrophosphate ratio, pH and other parameters were varied. In vivo distribution of different sup(99m)Tc-Sn-pyrophosphate complexes permitted the selection of the most suitable complex for sceletal scanning. The investigated complex is being successfully applied in human scintigraphy of bones in the Laboratory for Radioisotope Applications of the Institute for Tubercolosis and Pectoral Diseases in Sremska Kamenica.

  6. Muscle necrosis in the extremities: evaluation with Tc-99m pyrophosphate scanning--a retrospective review

    International Nuclear Information System (INIS)

    Timmons, J.H.; Hartshorne, M.F.; Peters, V.J.; Cawthon, M.A.; Bauman, J.M.

    1988-01-01

    A retrospective review was done of 34 extremities studied between 1981 and 1985 with technetium-99m pyrophosphate scanning; 22 were subsequently amputated. Results of detailed pathologic examination or immediate postoperative examination of the resected extremity were available in 16 cases. In these cases, scanning had allowed correct prediction of the level of amputation and of the specific areas of muscle infarction in 13 cases. In the one case in which amputation was performed for infection rather than muscle necrosis, the lack of necrosis was correctly predicted with the scan. The limited results of this study indicate that the Tc-99m pyrophosphate scan allows the location of necrotic muscle to be predicted accurately and may therefore be a useful adjunct in determining the best level for ultimate amputation. Special caution is required in those cases in which muscle necrosis is due to acute causes (e.g., traumatic thrombosis) rather than chronic vascular disease

  7. Emission tomography with sup(99m)Tc-pyrophosphate in the diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Poeyhoenen, L.; Uusitalo, A.; Virjo, A.

    1985-01-01

    Electrocardiograms (ECG) and enzyme criteria are usually used to confirm the diagnosis of acute myocardial infarction in the case of chest pain. However, ECG is not always diagnostic. Elevated enzyme values may be due to causes other than myocardial infarction. In uncertain cases, the ECG and enzyme criteria can be supplemented by emission tomography, performed with technetium pyrophosphate that will accumulate in the site of infarction. Twenty-nine patients with suspected acute myocardial infarction were studied with emission tomography. Of these 12 had acute transmural infarction. Both enzyme tests and ECG were diagnostic in only 7 of these 12 cases, 4 had positive enzyme tests but a nondiagnostic ECG and in one case neither enzymes nor ECG were diagnostic. In 11 patients the infarcted myocardial area was detected with emission tomography. Six patients had acute nontransmural infarction. Only 2 of these had positive emission tomography. The chest pain was not due to infarction in 11 patients. All these patients had negative emission tomography. The sensitivity of emission tomography was 92% and specificity 100% in transmural acute infarction. In nontransmural infarction the specificity was only 33%. Emission tomography is a valuable diagnostic tool. It may be the decisive method when ECG and enzymes are not diagnostic. Emissin tomography also shows the localization and size of the infarcted area in the myocardium. (orig.)

  8. Experimental substantiation of myocardial affection visualization by means of pyrophosphate-sup(99m)Tc

    Energy Technology Data Exchange (ETDEWEB)

    Shepeleva, I I; Saprygin, D B; Saks, V A; Kramer, A A; Kashtelyan, L S [Akademiya Meditsinskikh Nauk SSSR, Moscow. Vsesoyuznyj Kardiologicheskij Nauchnyj Tsentr; Akademiya Meditsinskikh Nauk SSSR, Moscow. Inst. Serdechno-Sosudistoj Khirurgii)

    1979-03-01

    To study the mechanisms of accumulation of the pyrophosphate-sup(99m)TcSn complex a model of an isolated rat heart perfused according to Langendorf under conditions was used. The results of the experiment showed that intensive accumulation of the radionuclide in the myocardium began already at the first minutes of anoxia, i.e. at the stage of reversible changes when reoxygenation brought about a drop in the level of accumulated radioactivity down to the normal limit. Anoxia lasting for 5 minutes led to a 10 per cent accumulation of the entire dose of radioactivity in the myocardium, that lasting for 10 minutes-up to 18 per cent. As a result of a 5-minute reoxygenation after a 10-minute anoxia the level of accumulated radioactivity fell down to 4-5 per cent. Reoxygenation after s 20-30-minute anoxia produced no effect on the curve of the radionuclide accumulation in the heart. Alongside radiometric studies the content of macroergs (ATP and creatine phosphate) in the norm and in development of anoxia was determined. The accumulation of the pyrophosphate-sup(99m)TcSn complex in the myocardial cells is closely connected with energy metabolism of the cell and, is apparently, caused by changes in the cell membrane permeability by this complex.

  9. Effect of EHDP on calcium accumulation and technetium-99m pyrophosphate uptake in experimental myocardial infarction

    International Nuclear Information System (INIS)

    Buja, L.M.; Tofe, A.J.; Parkey, R.W.; Francis, M.D.; Lewis, S.E.; Kulkarni, P.V.; Bonte, F.J.; Willerson, J.T.

    1981-01-01

    Ethane-l-hydroxy-1,1-diphosphonate (EHDP) inhibits bone mineral growth. This study was performed to test the hypothesis that EHDP would interfere with the process of calcium uptake and deposition in evolving myocardial infarction and thereby influence other parameters, including technetium-99m pyrophosphate (Tc-99m PYP) uptake and scintigraphic visualization of the infarcts. Permanent occlusion of the left anterior descending coronary artery (LAD) was produced in beagles. In seven dogs, serum EHDP was maintained at 10-15 μg/ml for 24 hours by continuous i.v. infusion, and seven control dogs were infused with saline. The Tc-99m PYP was infected 2 hours before sacrifice. EHDP-treated dogs showed a mild decrease (20%) in mean calcium content of infarcted myocardium (102.4 +/- 6.4 μg [+/- SEM] per gram wet weight [n = 51] vs 126.7 +/- 9.5 [n = 49] [p -3 ] [n = 46] vs 28.9 +/- 4.3 [n = 46] [p < 0.005]) and a marked decrease (65%) in infarct-to-normal ratio (6.1 +/- 0.9 [n = 6] vs 15.9 +/- 3.7 [n = 6] [p < 0.05]). Positive relationships were demonstrated between myocardial Tc-99m PYP and calcium levels in the EHDP-treated dogs (r = 0.69) and the control dogs (r = 0.77). Infarct size and regional myocardial blood flow changes were similar in the EHDP-treated and control dogs. The average grade (0-4+) of the Tc-99m PYP myocardial scintigrams for infarcts greater than 3.5 g was 2.4 +/- 0.2 for control dogs and 1.1 +/- 0.4 for EHDP-treated dogs (p < 0.05). Thus, EHDP infusion at the dose tested produced a mild decrease in calcium accumulation in canine infarcts; however, it produced a greater reduction in Tc-99m PYP uptake in the infarcts

  10. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki

    1986-09-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate (/sup 99m/Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using /sup 99m/Tc-PPi with thallium-201-gated myocardial scintigraphy (/sup 201/Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p < 0.01, y = 772x + 13900). Correlation of infarct size with peak serum creatine kinase level was also significant (r = 0.66, p < 0.01, y = 10.6x + 693). In conclusion, SPECT with /sup 99m/Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction.

  11. Quantitative analysis of acute myocardial infarction using single photon emission computed tomography using technetium-99m pyrophosphate

    International Nuclear Information System (INIS)

    Fujiwara, Yasushi; Kokubu, Tatsuo; Murase, Kenya; Hamamoto, Ken; Itoh, Taketoshi; Doiuchi, Junji; Ochi, Takaaki.

    1986-01-01

    The usefulness of single photon emission computed tomography (SPECT) using technetium-99m pyrophosphate ( 99m Tc-PPi) was evaluated in 15 patients with acute myocardial infarction. SPECT was performed with a rotating gamma camera after conventional planar images were made. Infarct size was measured from transaxial images of myocardial pyrophosphate uptakes. In each slice, the boundary was defined by subtracting 70 percent of the maximal counts and the number of voxels automatically counted. This subtraction rate was determined by phantom study and by compraing SPECT using 99m Tc-PPi with thallium-201-gated myocardial scintigraphy ( 201 Tl gated SPECT). The planar images showed diffuse uptakes in two of the 15 patients, and in these cases it was difficult to detect the infarct site. In contrast, SPECT images clearly imaged the infarct site consistent with the electrocardiographic findings, and they were definitely separated from the uptakes in the bones in all cases. Infarct size, ranging from 3.4 ml to 78.3 ml, correlated well with cumulative creatine kinase release (r = 0.84, p 99m Tc-PPi is a useful means of investigating the spatial distribution of pyrophosphate uptake and of evaluating the size of myocardial infarction. (author)

  12. Quantification of myocardial infarct size by technetium-99m pyrophosphate single photon emission computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Yamamoto, Hiromichi; Fukuyama, Takaya; Aoki, Makoto; Inou, Tetsuji; Ashihara, Toshiaki; Nabeyama, Shyohzou; Yamamoto, Yuhsuke

    1989-04-01

    Myocardial infarct size in 41 patients with the first attack of acute transmural myocardial infarction (MI) was assessed by technetium-99m pyrophosphate single photon emission computed tomography (/sup 99m/TcPYP-SPECT). A ratio of the number of voxels of /sup 99m/TcPYP uptake into the infarct area to that into the thorax was calculated as a parameter of MI size. The ratio was positively correlated with both peak CPK activity (r=0.53, p<0.005, n=24) and extent score in /sup 201/Tl-SPECT (r=0.70, p<0.005, n=14) significantly in patients with anterior MI but not in patients with inferior MI. There was also significant negative correlation between the ratio and the left ventricular ejection fraction (LVEF) measured by RI angiography in both acute (r=-0.67, p<0.005, n=18) and chronic (r=-0.75, p<0.005, n=25) phases in patients with anterior MI. Recovery in LVEF at chronic phase was noted in patients with small anterior MI but not with large anterior MI. Eight of 14 patients with inferior MI had right ventricular MI, that might have affected evaluation of MI size and resulted in no correlation between variables. It was suggested that /sup 99m/TcPYP-SPECT was a useful method to evaluate MI size and to predict prognosis of cardiac function in patients with anterior MI but not in patients with inferior MI. (author).

  13. Technetium-99m pyrophosphate scintigraphy for the detection of acute myocardial infarction. How useful is it

    International Nuclear Information System (INIS)

    Desai, A.G.; Berger, B.C.; Shin, Y.W.; Park, C.H.; Madsen, M.T.

    1985-01-01

    To evaluate the contribution of Tc-99m pyrophosphate scintigraphy (TPS) on the overall management of patients suspected of having acute myocardial infarction (AMI), hospital records of 58 consecutive patients who underwent TPS, were evaluated in depth. The results indicate that TPS was essential for the diagnosis of AMI in 16% of the patients. TPS was most rewarding in perioperative patients and in patients with borderline or uninterpretable electrocardiographic and enzyme changes. Also, in some cases, TPS was able to confirm or exclude the diagnosis of AMI prior to the confirmation by serial electrocardiograms (ECG) and serial enzyme changes. TPS was less rewarding in patients with clinically low index of suspicion for AMI. It may also be confusing in patients with high clinical likelihood of AMI and a history of prior myocardial infarction because of the possibility of persistently positive TPS in some of these patients. Considering the limitations of ECGs, the cardiac enzymes, and atypical clinical presentations in the patient population we evaluated, TPS appears to be fairly accurate when the scintigraphic findings are compared with the final diagnosis at the time of discharge from the hospital

  14. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    Energy Technology Data Exchange (ETDEWEB)

    Tamaki, S; Kadota, K; Kambara, H; Suzuki, Y; Nohara, R; Murakami, T; Kawai, C; Tamaki, N; Torizuka, K [Kyoto Univ. (Japan). Faculty of Medicine

    1984-07-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man.

  15. Emission computed tomography with technetium-99m pyrophosphate for delineating location and size of acute myocardial infarction in man

    International Nuclear Information System (INIS)

    Tamaki, S.; Kadota, K.; Kambara, H.; Suzuki, Y.; Nohara, R.; Murakami, T.; Kawai, C.; Tamaki, N.; Torizuka, K.

    1984-01-01

    Emission computed tomography with technetium-99m pyrophosphate was used to delineate the location and estimate the size of myocardial infarcts in 20 patients with documented acute myocardial infarction. Tomography was performed after planar imaging within 2-5 days after the onset of infarction. Infarct volume was measured from the tomographic images by computerised planimetry and compared with the cumulative release of creatine kinase MB isoenzyme. The planar images showed discrete myocardial uptake in 13 of the 20 patients and diffuse uptake throughout the cardiac region in the remaining seven. In contrast, the tomographic images clearly delineated myocardial uptake by avoiding confusion of myocardial activity with that of surrounding structures, particularly bones, in all patients. For the 10 patients whose infarct size was assessed by analysis of the creatine kinase MB curve there was a close correlation between infarct volume estimated by tomography and by cumulative creatine kinase MB release. Thus emission computed tomography can provide a three dimensional map of technetium-99m pyrophosphate distribution within the heart and is thus able accurately to localise and estimate the size of myocardial infarcts in man. (author)

  16. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    Science.gov (United States)

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  17. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy

    International Nuclear Information System (INIS)

    Cowley, M.J.; Mantle, J.A.; Rogers, W.J.; Russell, R.O. Jr.; Rackley, C.E.; Logic, J.R.

    1979-01-01

    It has been suggested that diffuse 99m Tc pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60 to 90 min following the injection of 12 to 15 mCi of 99m Tc pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to rule out infarction 24 to 72 hr after onset of suggestive symptoms

  18. Comparison of pyrophosphate and gluconate scan of dog hearts with experimental cardiomyopathy

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Kafka, P.; Kubicek, J.; Vizda, J.; Mazurova, Y.; Veverkova, O.

    1983-01-01

    High intravenous doses of theophylline with adrenalin were used to produce experimental cardiomyopathy in dogs. This damage was visualized scintigraphically using either sup(99m)Tc-pyrophosphate (10 dogs) or sup(99m)Tc-gluconate (another 10 dogs). Scintigraphic examinations using sup(99m)Tc-pyrophosphate were carried out 48 hours after the damage had developed: in two dogs the examination was negative, in two cases boundary, in 6 cases the scintigraphic finding was clearly positive. sup(99m)Tc-gluconate was used in the examination of 5 animals four hours after the damage had developed. In this case the scan was significantly positive in all cases. The gluconate scan was made 24 hours after damage, again in 5 dogs. Here the positive change was less explicit, in one case the finding was negative. Histological examination of the affected myocardium showed in all cases a very light damage, in many instances on the limit of resolution by light microscopy. The findings were always degenerative (dystrophic) changes and microcirculation disorders without any necrosis. The work showed that both studied radiopharmaceutical preparations are a very sensitive but nonspecific indicator of non-ischemic disorders of the myocardium. For sup(99m)Tc-gluconate this is an original finding. (author)

  19. Usefulness of acute myocardial infarct size and localization using Tc-99m-pyrophosphate and single photon emission computed tomography

    International Nuclear Information System (INIS)

    Fujisue, Ryu; Ohyanagi, Mitsumasa; Todo, Yasuhiro

    1985-01-01

    Tc-99m-Pyrophosphate(PYP)myocardial emission computed tomography(ECT) was performed following standard planar imaging in 45 patients(pts) with acute myocardial infarction(AMI). All of them had clinical, electrocardiographic and enzymatic evidence of AMI. The planar imaging and ECT imaging were interpreted independently by two observers who had no knowledge of the clinical findings. 10 pts(22.2 %), who showed diffuse uptake on planar imaging, revealed focal uptake on ECT imaging without cardiac blood pool imaging. And there is no disagreement as to interpretation of the infarct location by two observers on ECT imaging. We conclude that ECT imaging with Tc-99m-PYP increases interobserver agreement in the diagnosis and localization of AMI and may lead to more accurate localization and sizing of AMI, espesically in cases of diffuse cardiac activity on planar imaging. (author)

  20. Effect of methylprednisolone upon technetium-99m pyrophosphate assessment of myocardial necrosis in the canine countershock model

    International Nuclear Information System (INIS)

    Schneider, R.M.; Hayslett, J.P.; Downing, S.E.; Berger, H.J.; Donabedian, R.K.; Zaret, B.L.

    1977-01-01

    RRepeat DC countershock reproducibly results in myocardial necrosis in dogs. In this model, myocardial technetium-/sup 99m/ pyrophosphate (PYP) uptake correlates linearly with tissue creatine kinase depletion (r = -0.83). The effect of pretreatment with methylprednisolone (MP) was studied with PYP in 25 dogs. In myocardium damaged by countershock, 12 MP dogs had higher tissue radioactivity sample:normal (S:N) ratios than control (P < 0.05), suggesting increased tissue injury. However, by several other measures of tissue damage, the two groups did not differ. MP-elevated PYP S:N ratios were explained by reduced PYP activity in normal myocardium of MP dogs. Further experiments in 21 dogs revealed that renal PYP clearance, which correlated with glomerular filtration rate (GFR) as measured by creatinine clearance, was increased in MP dogs, resulting in accelerated urinary excretion of PYP (46.9 +- 3.6 vs 35.8 +- 2.4 percent injected dose in one hour, P < 0.01), and reduced blood PYP. Thus, MP does not modify countershock-induced myocardial injury. However, by increasing GFR, MP increased PYP excretion, resulting in lowered blood and normal zone myocardial PYP, thereby spuriously affecting myocardial PYP tissue uptake data

  1. Increased incidence and clinical correlation of persistently abnormal technetium pyrophosphate myocardial scintigrams following acute myocardial infarction in patients with diabetes mellitus

    International Nuclear Information System (INIS)

    Nicod, P.; Lewis, S.E.; Corbett, J.C.; Buja, L.M.; Henderson, G.; Raskin, P.; Rude, R.E.; Willerson, J.T.

    1982-01-01

    Persistently abnormal /sup 99m/Tc stannous pyrophosphate myocardial scintigrams (PPi+) appear to be associated with a relatively poor prognosis after acute myocardial infarction (AMI). To assess the incidence and implications of PPi+, we performed a retrospective analysis in 29 patients with and 25 patients without diabetes mellitus who had abnormal myocardial scintigrams within 4 days of AMI and who had follow-up scintigrams at least 3 months after hospital discharge. There were no significant differences between patients with and without diabetes as regards age, incidence of transmural or nontransmural AMI, or degree of left ventricular dysfunction after AMI. Persistently abnormal PPi+ occurred more commonly in patients with diabetes than in nondiabetic patients (18 of 29, 62%, compared to 3 of 25, 12%; p less than 0.001). Patients with chronic PPi+ had more frequent cardiac complications following hospital discharge (p less than 0.005) including death, recurrent AMI, unstable angina, and intractable congestive heart failure. Postmortem analysis in two patients with diabetes and chronic PPi+ revealed marked myocytolysis. Thus, patients with diabetes mellitus have an increased incidence of post-AMI persistently abnormal technetium (PPi+) scintigrams and relatively poor prognosis following myocardial infarction

  2. Lutetium pyrophosphates

    International Nuclear Information System (INIS)

    Dzhabishvili, N.A.; Davitashvili, E.G.; Orlovskij, V.P.; Kargareteli, L.N.

    1986-01-01

    Reaction between lutetium nitrate and pyrophosphates of sodium, potassium and ammonium in aqueous solution is studied, using the method of residual concentrations. New compounds are isolated, their composition and physicochemical properties are considered. Data on solubility in the systems at 25 deg C are given. All the hydrate pyrophosphates are roentgenoamorphous, they are crystallized only when heated. Thermal decomposition of lutetium pyrophosphate is investigated

  3. Clinical indications for Thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.J.; Kelly, D.T.

    1982-01-01

    Thallium-201 myocardial perfusion scanning can assess regional myocardial perfusion non-invasively. As it is both time-consuming and expensive its use should be restricted to specific diagnostic problems. The clinical indications in known or suspected coronary artery disease are reviewed. In suspected coronary artery disease thallium scanning is most useful in patients with chest pain when the exercise ECG is uninterpretable, in men with probable angina but a negative exercise ECG, or conversely a positive exercise ECG without typical angina, and in women with probable angina and either a positive or a negative exercise ECG. In known coronary artery disease, thallium scanning may help determine the functional significance of a coronary obstruction found at angiography and may determine the site of myocardial ischaemia when multiple obstructions are present

  4. Infarct size in patients with acute myocardial infarction estimated by emission computed tomography with technetium-99m pyrophosphate. Relation to creatine phosphokinase release

    Energy Technology Data Exchange (ETDEWEB)

    Maruyama, Jun-ichi; Onodera, Sokichi; Imura, Suguru; Marutani, Yoshiaki; Takahori, Takashi; Nasuhara, Koh-ichi

    1986-09-01

    To evaluate the usefulness of single photon emission computed tomography (SPECT) with technetium-99m-pyrophosphate (/sup 99m/Tc-PYP) for estimating infarct size, we compared SPECT data with maximum creatine phosphokinase values. Background threshold was established in a series of phantom experiments. When a 40 % cut-off was applied, the SPECT data most closely approximated actual phantom volumes. Therefore, the 40 % cut-off level was used in the present study. In 10 patients with acute myocardial infarction, planar /sup 99m/Tc-PYP myocardial scintigraphy and SPECT using a rotating gamma camera were performed two days after the initial myocardial infarction episode. The maximum creatine phosphokinase value (CPKmax) was also measured repeatedly following the episode. When the infarct size measured by SPECT using transaxial images and calculated by the pixel counts, it correlated very closely with CPKmax (r = 0.94). Most studies so far have reported that the CPKmax level reflects infarct size. We conclude that the infarct size as measured by /sup 99m/Tc-PYP SPECT closely approximates the actual infarct size, and that this method is useful to determine the severity of infarcts clinically. Among the 10 patients in this series, three of five with infarcts greater than 60 ml died of pump failure. Therefore, we may be able to predict prognosis after accumulating more such cases and improving the methodology.

  5. Change perspective to increase diagnostic accuracy of ultrasonography in calcium pyrophosphate dihydrate deposition disease! A new approach: the axial scan of the meniscus

    Directory of Open Access Journals (Sweden)

    G. Filippou

    2015-03-01

    Full Text Available Ultrasonography (US is a relevant tool in the study of calcium pyrophosphate dihydrate (CPP deposition disease. However, differential diagnosis of hyperechoic deposits within the fibrocartilage can be difficult; moreover, US study is limited by the need of an adequate acoustic window. We describe a US scanning technique that offers a new viewpoint in the study of knee meniscal structure: a longitudinal scan performed according to the long axis of meniscus. This technique proves to be particularly useful for the identification of CPP deposition, but could also improve the US diagnostic utility and accuracy in other meniscal pathologies.

  6. Simultaneous thallium-201/technetium-99m pyrophosphate tomography in patients with acute myocardial infarction: comparison of rotational SPECT and seven pinhole tomography

    International Nuclear Information System (INIS)

    Krause, T.; Schuemichen, C.; Beck, A.; Moser, E.; Zeiher, A.

    1992-01-01

    Simultaneous Tl-201/Tc-99m pyrophosphate (PPi) tomography was compared to Tc-99m PPi tomography and rotational SPECT (SPECT) was compared to seven pinhole tomography (9-PHT), respectively, in 19 patients with acute myocardial infarction (AMI). The results were correlated to electrocardiographic and angiographic findings. With Tl-201/Tc-99, PPi, all infarctions were detected and site of infarction was determined, independent of the tomographic technique used. There was no significant difference between the two acquisition techniques 7-PHT and SPECT concerning spatial extent of Tc-99m PPi accumulation and the uptake ratio. However, using only Tc-99m PPi without Tl-201 as anatomical marker, SPECT detected 15/19 infarctions. In 7 of these 15 cases infarction site was correctly determined. 7-PHT detected 11/19 and site was correctly determined in 9/11 infarctions. Myocardial infarctions which failed diagnosis using Tc-99m PPi alone showed significantly smaller spatial extent of Tc-99m PPi accumulation and necrosis to blood pool ratio was lower as assessed by Tl201/Tc-99m PPi tomography. In conclusions, tomography using simultaneous Tl-201/Tc-99m PPi imaging is a reliable technique for diagnosis and localization of AMI. For this reason, results obtained with SPECT and 7-PHT are comparable. Independent of the tomographic technique used, combined imaging is superior to Tc-99m PPi alone without Tl-201 as additional anatomical marker (orig./MG) [de

  7. Usefulness of dual energy single photon emission computed tomography with 99mTc-pyrophosphate and 201TlCl in diagnosis of acute myocardial infarction

    International Nuclear Information System (INIS)

    Shohgase, Takashi; Okita, Kohichi; Sakai, Hiroto; Fukuda, Hiroyuki; Anzai, Teisuke; Yamaguchi, Masashi; Koseki, Yukio; Tsujita, Naoyuki; Itoh, Hideki

    1990-01-01

    The dual energy single photon emission computed tomography (D-SPECT) with 99m Tc-Pyrophosphate and 201 TlCl was evaluated, using Bull's Eye Map representation in 30 patients with acute myocardial infarction. D-SPECT imaging for infarct detection was 100% sensitive. The patients were divided into two groups. One group had an overlap of accumulation of 99m Tc and 201 TlCl in the infarct zone and the other had no overlap. Fifteen of 19 patients (78.9%) in whom reperfusion was successful showed an overlap. Ten of 11 patients in whom reperfusion was unsuccessful showed no overlap. In the patients with successful reperfusion, the group that showed an overlap had a shorter interval between the onset of acute myocardial infarction and the reperfusion of coronary artery than the group that showed no overlap. But one case showed that collateral circulation had an influence on the overlap. In conclusion, using Bull's Eye Map representation, D-SPECT was useful to detect infarct and the overlap of accumulation of 99m Tc and 201 TlCl might be used as an index of early recanalization. (author)

  8. Assessment of myocardial perfusion using a new scanning agent

    Energy Technology Data Exchange (ETDEWEB)

    Khalil, M.N

    1987-01-01

    This work assessed a new compound: Tc-99m tertiary butyl isonitrile (T-BIN) in scanning the normal myocardium in dogs. Experimentally induced myocardial infarcts (M.I.) were detected. The compound cleared significantly from the blood within 15 minutes and from the lungs within an hour after intravenous administration. Liver uptake was high and remained so. Cardiac uptake occurred quickly and continued for 6 hours. Comparable results were obtained in normal humans and patients. Myocardial scanning was best after 60 minutes at rest or 30 minutes after exercise. Liver uptake sometimes obscured the detection of inferior M.I. but this problem was reduced using a 45/sup 0/ left anterior oblique view with a 20/sup 0/ cranial tilt. At rest 9/10 patients with M.I. showed defects corresponding to the infarct sites. In 20 patients with angina pectoris 16 had perfusion defects on exercise. In 15/16 patients reversible ischaemia was demonstrated. The reperfusion scans were best obtained at 4 hours post exercise. Both Tl-201 and T-BIN detected equally the infarcts (3/3) but in patients with angina 8/10 with T-BIN and 6/10 with Tl-201 showed defects. ECG gating of the T-BIN scans was also studied.

  9. An incidental finding of myocardial uptake on HDP bone scan

    International Nuclear Information System (INIS)

    Smith, T.

    1998-01-01

    Full text: A 75 year old male referred with a history of wrist pain for a HDP bone scan(700Mbq) had dynamic and blood pool images. A posterior sweep and planar images were performed after 2 hours. The scan demonstrated a fracture of the left radial styloid, other degenerative arthritis and diffuse tracer uptake throughout the myocardium. The differential diagnoses included cardiac amyloid, myocardial infarction (MI) and calcific pericarditis. The patient, a non insulin dependent diabetic with previous MI in 1978 and hypertension had nocturnal dyspnoea and no chest pain. Chest X-ray was normal. ECG revealed old inferior infarct. Echocardiography showed mild hypokinesis of the inferior wall, low normal LV contractility, normal pericardium and no evidence of amyloid. A Rest (400Mbq) / Stress(1200Mbq) Sestamibi(MIBI) was performed to assess status of ischaemic heart disease (IHD). The patient experienced leg fatigue and shortness of breath but no chest pain. Rest ECG showed sinus bradycardia with ST/T wave changes. Stress ECG showed ST segment depression (0.5mm). Planar and SPECT studies showed reversible perfusion defects in the anterior wall and apex with a fixed inferolateral defect. Gated SPECT showed normal wall motion apart from the inferolateral infarct. The exact cause of the HDP uptake in the myocardium is unknown. The echo findings exclude amyloid or pericarditis. The MIBI study confirmed a small inferolateral infarct and myocardial ischaemia in the anterior wall and apex. The scan has affected patient management by diagnosing a fracture of the radial styloid and confirming previous infarction and myocardial ischaemia. An open view must be taken of the cardiac HDP uptake. The most likely diagnosis in this patient is silent IHD, which has been demonstrated in one other case known to us

  10. Detection of Myocardial Infarcts by In-Vivo Scanning using Mercurascan

    Energy Technology Data Exchange (ETDEWEB)

    Vavrejn, B. [Research Institute for the Medical Use of Radioisotopes, Prague, Czechoslovak Socialist Republic (Czech Republic); Malek, P.; Kolc, J. [Institute for Clinical and Experimental Surgery, Prague, Czechoslovak Socialist Republic (Czech Republic); Ratusky, J. [Institute of Organic Chemistry and Biochemistry, Czechoslovak Academy of Sciences, Prague, Czechoslovak Socialist Republic (Czech Republic); Kronrad, L. [Institute for Nuclear Research, Rez near Prague, Czechoslovak Socialist Republic (Czech Republic)

    1969-05-15

    A method is described in which mercurascan (a hydroxymercury derivative of fluorescein) is injected intravenously into dogs before scanning so as to detect myocardial infarction as a 'hot' area on the scan. Experiments with some 150 dogs show that myocardial ischaemia could be demonstrated by in-vivo scanning within a short period of time after administration of mercurascan. (author)

  11. Evaluating microvascular obstruction after acute myocardial infarction using cardiac magnetic resonance imaging and 201-thallium and 99m-technetium pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Onishi, Takayuki; Kobayashi, Isshi; Onishi, Yuko; Kawashima, Tomoyuki; Muramoto, Hirotaka; Nakamura, Hiroaki; Nagata, Yasutoshi; Umezawa, Shigeo; Niwa, Akihiro

    2010-01-01

    Few studies have compared the ability of cardiac magnetic resonance (CMR) with that of scintigraphy using 201-thallium (201-Tl) and 99m-technetium pyrophosphate (99m-Tc PYP) to evaluate microvascular obstructions (MOs). In the present study the relationship between the scintigraphic and CMR characteristics of MOs after acute myocardial infarction (MI) was examined. The 14 patients (age 69±8 years, 11 males) underwent 201-Tl/99m-Tc PYP single photon emission computed tomography (SPECT) 7±3 days, initial CMR 16±12 days, and follow-up CMR 193±20 days after a reperfused first acute MI. Each image was analyzed using a 17-segment model. Segmental extent of delayed enhancement (DE), wall motion (WM) and degree of 201-Tl uptake were scored in 238 segments. Of 91 MI segments, MO was recognized in 22 (25%) segments on CMR. WM was significantly better in proportion to 201-Tl uptake (P=0.01) in MO segments. All 8 MO segments with WM improvement at follow-up had 99m-Tc PYP uptake, although only 3 (21%) of 14 MO segments that did not show WM improvement at follow-up had 99m-Tc PYP uptake (P=0.001). 99m-Tc PYP and 201-Tl scintigraphy have the potential to predict WM status and improvement of the MO region after reperfused acute MI. (author)

  12. 99mTc bone scanning agents preparation and chemical analysis of Tc(Sn)pyrophosphate, Tc(Sn)MDP and Tc(Sn)HMDP

    International Nuclear Information System (INIS)

    Kroesbergen, J.

    1986-01-01

    This thesis describes a comparison of the preparation, composition and properties of three bone scanning agents: 99m Tc(Sn)pyrophosphate, 99m Tc(Sn)MDP and 99m Tc(Sn)HMDP. This study has been performed for two reasons: First to investigate the preparation and composition of the radiopharmaceuticals as a function of experimental conditions. Together with previously reported results for 99m Tc(Sn)EHDP, obtained in a similar way, this enables to use well-defined preparations of the bone scanning agents. Secondly to gain an insight in the mechanism in which the agents behave 'in vivo'. Because the 'in vivo' process is too complicated to study directly, it seemed more appropriate to perform 'in vitro' investigations as simplifications of the 'in vivo' situation. 304 refs.; 26 figs.; 31 tabs

  13. Calcium Pyrophosphate Deposition (CPPD)

    Science.gov (United States)

    ... Patient / Caregiver Diseases & Conditions Calcium Pyrophosphate Deposition (CPPD) Calcium Pyrophosphate Deposition (CPPD) Fast Facts The risk of ... young people, too. Proper diagnosis depends on detecting calcium pyrophosphate crystals in the fluid of an affected ...

  14. Is attenuation correction of myocardial SPECT scans worth the effort?

    International Nuclear Information System (INIS)

    Bui, C.; Nguyen, D.; Dixson, H.; Saunders, C.; Cook, P.; Burnett, P.; Croll, F.; Dunn, R.; Hasche, E.; Kelleher, P.; Nasser, F.; Wilson, D.; Lee, K.

    2000-01-01

    Full text: Gated (GS), attenuation-corrected (AC) and non-attenuation-corrected (NAC) myocardial SPECT scans were performed after injection of 99 Tc m -Sestamibi (MIBI) at peak stress in 253 patients between September 1998 and March 1999. 60 patients have undergone cardiac catheterisation (37 males, 23 females, age range 34-80). For whole heart analysis, significant coronary disease was defined as 50% or greater diameter narrowing in any of the coronary arteries and/or documented myocardial infarction. For vascular territory analysis, significant coronary disease was defined as 50% or greater diameter narrowing of any artery in that territory. The three coronary artery territories were assigned as: left anterior descending (LAD), left circumflex (LCA) and right coronary (RCA). The septum, apex and anterior wall; the lateral wall; and the inferior wall were assigned to the LAD; LCA; and RCA territories respectively. In conclusion for this selected subgroup of patients with angiographic follow-up, NAC, AC and GS were of similar accuracy in the detection of significant CAD in both whole heart analysis and individual vascular territory analysis. AC and GS were of superior specificity when compared with NAC in both whole heart analysis and individual vascular territory analysis. AC and GS may be of additional diagnostic value in improving the specificity of NAC. Further outcome data will be presented. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  15. Evaluation of the severity of anterior myocardial infarction (single-vessel disease) by stress myocardial scanning

    International Nuclear Information System (INIS)

    Kobayashi, Mitsuru; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Hayashi, Makoto; Saito, Muneyasu; Sumiyoshi, Tetsuya

    1986-01-01

    Stress thallium-201 scanning was performed in 57 patients with ≥ 75 % stenosis in the left anterior descending artery. The ratio of lung uptake to heart uptake was defined as lung thallium uptake. For quantitative assessment of infarct size and the severity of ischemia, defect score and ischemic score were derived, respectively, from circumferential profile analysis. Lung thallium uptake at stress tended to increase with an increase in both defect and ischemic scores. The increase in lung thallium uptake also tended to be associated with a decrease in LVEF as determined by cardiac catheterization. The results indicate that stress thallium scanning is of value in the evaluation of the severity of myocardial infarction. (Namekawa, K.)

  16. Myocardial contusion following nonfatal blunt chest trauma

    International Nuclear Information System (INIS)

    Kumar, S.A.; Puri, V.K.; Mittal, V.K.; Cortez, J.

    1983-01-01

    Currently available diagnostic techniques for myocardial contusion following blunt chest trauma were evaluated. We investigated 30 patients prospectively over a period of 1 year for the presence of myocardial contusion. Among the 30 patients, eight were found to have myocardial contusion on the basis of abnormal electrocardiograms, elevated creatine phosphokinase MB fraction (CPK-MB), and positive myocardial scan. Myocardial scan was positive in seven of eight patients (87.5%). CPK-MB fraction was elevated in four of eight patients (50%). Definitive electrocardiographic changes were seen in only two of eight patients (25%). It appears that myocardial scan using technetium pyrophosphate and CPK-MB fraction determinations are the most reliable aids in diagnosis of myocardial contusion following blunt chest trauma

  17. Is attenuation correction of myocardial SPET scans worth the effort?

    International Nuclear Information System (INIS)

    Nguyen, D.; Saunders, C.; Dixson, H.; Cook, P.; Burnett, P.; Croll, F.; Dunn, R.; Hasche, E.; Kelleher, P.; Nasser, F.; Wilson, D.; Lee, K.

    1999-01-01

    Full text: In this prospective study, we compared gated (GS), attenuation-corrected (AC) and non-attenuation-corrected (NAC) myocardial SPET scans. 119 consecutive patients were scanned after 800 MBq 99 Tc m -Sestamibi (MIBI) injected at peak stress. AC studies were performed using a Siemens Multispect 3 triple-headed camera with a MμSIC attenuation correction system. Transmission data were provided by an Am241 line source mounted opposite an offset fan beam collimator. Simultaneous emission data were collected from all 3 heads over a 360deg rotation (acquisition time 25 min). The NAC and GS studies were performed using a Siemens ECAM variable-angle dual-headed gamma camera using 8 gating frames over a 90deg rotation (acquisition time 15 min). The myocardium was divided into 9 segments and the studies were reported separately by two observers. Clinical data and angiography results were obtained when available. For GS, myocardial segments with normal systolic wall thickening were considered to have normal perfusion. AC studies were used as the standard for measuring myocardial perfusion. In the 119 patients studied, the overall sensitivity, specificity and accuracy for NAC vs AC were 100%, 25%, 54% and for GS vs AC were 86%, 84% and 85% respectively. There were 265 abnormal segments on NAC. GS demonstrated normal thickening in 90/265 segments and AC demonstrated normal perfusion in 94/265 segments. There were 33 segments with discordant GS and AC. 16/33 segments (9 inferior, 3 anterior, 4 other) with normal thickening had abnormal perfusion on AC and 17/33 segments (9 inferior, 6 anterior, 2 other) with abnormal thickening had normal perfusion on AC. Weight and sex did not predict discordance. In conclusion, attenuation artefacts are common and are not predicted by body habitus or sex. They are usually accurately identified by normal systolic wall thickening on GS. GS is strongly recommended when AC is not available. AC provides additional information, particularly

  18. Quantitation of size of myocardial infarctions by computerized transmission tomography. Comparison with hot-spot and cold-spot radionuclide scans

    International Nuclear Information System (INIS)

    Gerber, K.H.; Higgins, C.B.

    1983-01-01

    The current study evaluated the ability to quantitate the volume of myocardial infarctions when they are outlined by intravenously administered contrast media in the myocardial perfusion phase and in the phase of delayed contrast enhancement of the infarct. Quantitation by contrast media was assessed from computerized transmission tomography (CTT) scans of the ex situ heart and compared with quantitation by technetium-99m (/sup 99m/Tc)pyrophosphate (/sup 99m/Tc PYP) and thallium-201 (201Tl) scans of the same ex situ hearts. True volume was defined by histochemical morphometry. CTT during the contrast perfusion phase uniformly underestimated infarct size but had a good correlation with true volume. CTT during enhancement phase correlated closely with true volume (r . 0.98) and most precisely measured true size (y . 1.06 X 0.23). The /sup 99m/Tc PYP scan overestimated infarct volume (predictive overestimation of 6 to 199%) but had a good correlation with true volume. 201Tl underestimated infarct volume but correlated well with true volume. Thus, quantitation of infarct volume from CTT scans performed during either the perfusion or infarct enhancement phase after intravenous contrast media provides a good estimate of true infarct volume. Delineation of the infarct by contrast media in the ex situ heart is more precise during the phase of delayed enhancement of the infarct

  19. Prognostic value of myocardial infarct size index, obtained with technetium-99m pyrophosphate and thallium-201 chloride scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sugihara, Masami [Kanazawa Univ. (Japan). School of Medicine

    1982-02-01

    In order to determine the usefulness of nuclear cardiology methods in evaluating infarction size and in predicting subsequent mortality, the infarction size index was calculated and their left ventricular ejection fraction (LVEF) was measured for 136 patients with acute myocardial infarction, by means of sup(99m)Tc- and /sup 201/Tl-scintigraphy. Sensitivity of sup(99m)Tc-scintigraphy was 84% (of 44 cases). The hot sup(99m)Tc-areas were measured by planimetry only in anterior transmural infarctions. For 15 patients followed for 25 months on the average, hot areas were 13.8 +- 10.8 cm/sup 2/ in survivors and 31.7 +- 18.2 cm/sup 2/ in non-survivors. Both a doughnut pattern and persistent hot area in scintigraphs were signs of poor prognosis. Sensitivity of /sup 201/Tl-scintigraphy was 86% (of 95 cases). The extent of /sup 201/Tl perfusion defects was determined in three views by the average ratio of the length of perfusion defects to that of the left ventricle (LV). Interobserver correlation was high (r = 0.89). As the percent /sup 201/Tl defect index increased, the peak value of creatine phosphokinase, the grade of Peel index, incidence of congestion on initial chest X-ray, and LV aneurysma all gradually increased. In 48 patients followed for 23 months on the average after discharge, the incidence of congestive heart failure and mortality also increased with the larger degree of percent /sup 201/Tl defect index. In particular, the prognosis was poor in patients who had the percent /sup 201/Tl defect index larger than 40%. The LVEF, measured with a computerized multi-crystal gamma camera, was well correlated with that of contrast ventriculography (r = 0.92). The patients who had severe LV dysfunction and the LVEF less than 31% also showed poor prognosis.

  20. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    International Nuclear Information System (INIS)

    Kondo, M.; Yuzuki, Y.; Arai, H.; Shimizu, K.; Morikawa, M.; Shimono, Y.

    1987-01-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) in group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion

  1. Thallium myocardial scanning in the emergency department evaluation of chest pain

    International Nuclear Information System (INIS)

    Mace, S.E.

    1989-01-01

    Chest pain is a common complaint of patients seen in the emergency department. The causes are legion, and range from the non-life threatening to the potentially catastrophic. Thallium heart scanning was done prospectively in 20 patients with a ''classic'' history for myocardial infarction (eight patients) or atypical chest pain and/or associated symptoms plus an abnormal ECG (12 patients) to discern a subset of patients from whom thallium scintography may be indicated in the emergency department. Although further investigation is needed, our preliminary study suggests that myocardial scanning with thallium can be a safe, fairly rapid, and useful objective parameter in the emergency department detection of suspected myocardial infarction, and in differential diagnosis of chest pain when other data such as the history, physical examination, ECG, or enzymes are inconclusive

  2. Do thallium myocardial perfusion scan abnormalities predict survival in sarcoid patients without cardiac symptoms

    International Nuclear Information System (INIS)

    Kinney, E.L.; Caldwell, J.W.

    1990-01-01

    Whereas the total mortality rate for sarcoidosis is 0.2 per 100,000, the prognosis, when the heart is involved, is very much worse. The authors used the difference in mortality rate to infer whether thallium 201 myocardial perfusion scan abnormalities correspond to myocardial sarcoid by making the simplifying assumption that if they do, then patients with abnormal scans will be found to have a death rate similar to patients with sarcoid heart disease. The authors therefore analyzed complete survival data on 52 sarcoid patients without cardiac symptoms an average of eighty-nine months after they had been scanned as part of a protocol. By use of survival analysis (the Cox proportional hazards model), the only variable that was significantly associated with survival was age. The patients' scan pattern, treatment status, gender, and race were not significantly related to survival. The authors conclude that thallium myocardial perfusion scans cannot reliably be used to diagnose sarcoid heart disease in sarcoid patients without cardiac symptoms

  3. Comparison Between Postprocessing Software and Repeated Scanning to Eliminate Subdiaphragmatic Activity in Myocardial Perfusion Scintigraphy

    International Nuclear Information System (INIS)

    Theerakulpisut, Daris; Chotipanich, Chanisa

    2016-01-01

    Myocardial perfusion single photon emission computed tomography (SPECT) is a powerful test of evaluation for coronary artery disease, but subdiaphragmatic radiotracer activity often interferes with the interpretation of inferior wall findings. This study aims to evaluate the effectiveness of using software elimination of the subdiaphragmatic activity for the assessment of its efficacy in the correctness of image interpretation and the overall image quality of myocardial perfusion scintigraphy (MPS). MPS studies from January 2010 to October 2012 at our institution were reviewed. Thirty-two SPECT studies were included, all of which had significant subdiaphragmatic activity in the first scan and needed to be delayed to let the activity clear. Each scan was interpreted by using semiquantitative scoring in 17 segments according to the degree of radiotracer uptake. The first scan, which had interfering activity, was manipulated by masking out the unwanted activity with software native to our image processing software suite. The manipulated images were then compared with delayed images of the same patient, of which the subdiaphragmatic activity was spontaneously cleared with time. The first scan masked by software correlated with the delayed scan for myocardial regions supplied by the left circumflex (LCx) and right coronary artery (RCA), but not the left anterior descending (LAD). However, the quality of the masked scans was perceived by the observer to be better in terms of quality and ease of interpretation. Using software to mask out unwanted subdiaphragmatic activity has no detrimental effect on the interpretation of MPS images when compared with delayed scanning, but it can improve subjective scan quality and ease of interpretation

  4. New application of myocardial infarct map using a dual isotope single photon emission computed tomography (SPECT) of [99mTc]pyrophosphate and [201Tl]chloride in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Hiroe, Michiaki; Muramatsu, Yasuji; Sugimoto, Keiichi; Tsujino, Motoyoshi; Maejima, Michihiro; Miyahara, Yasuhiro; Taniguchi, Koichi; Matsui, Susumu; Mizukawa, Katsumi.

    1988-01-01

    In 12 patients with acute myocardial infarction, a dual isotope SPECT was applied to describe a myocardial infarct map for detecting the site and the extent of the infarct. Threshold cut-off level was determined as 55 % for [ 99m Tc] and 35 % for [ 201 Tl] according to cardiac phantom studies. Multiple cardiac tomograms showed two different uptakes of the isotopes in indentical slices and regions. Then, color tomograms were described on the red and green image for [ 99m Tc] and for [ 201 Tl], respectively, and Bulls eye map was drawn in the two colored fashion as the myocardial infarct map. In all patients, the infarct map was successful to determine the exact site of the infarct and the overlapped area by the viable myocardium. In conclusion, this functional map of acute myocardial infarction may be useful for understanding three dimensional area of the infarct and the viable myocardium easily and exactly. (author)

  5. Localization of coronary artery disease with exercise electrocardiography: correlation with thallium-201 myocardial perfusion scanning

    International Nuclear Information System (INIS)

    Dunn, R.F.; Freedman, B.; Bailey, I.K.; Uren, R.F.; Kelly, D.T.

    1981-01-01

    In 61 patients with single vessel coronary artery disease (70 percent or greater obstruction of luminal diameter in only one vessel) and no previous myocardial infarction, the sites of ischemic changes on 12 lead exercise electrocardiography and on thallium-201 myocardial perfusion scanning were related to the obstructed coronary artery. The site of exercise-induced S-T segment depression did not identify which coronary artery was obstructed. In the 37 patients with left anterior descending coronary artery disease S-T depression was most often seen in the inferior leads and leads V4 to V6, and in the 18 patients with right coronary artery disease and in the 6 patients with left circumflex artery disease S-T depression was most often seen in leads V5 and V6. Although S-T segment elevation was uncommon in most leads, it occurred in lead V1 or a VL, or both, in 51 percent of the patients with left anterior descending coronary artery disease. A reversible anterior defect on exercise thallium scanning correlated with left anterior descending coronary artery disease (probability [p] less than 0.0001) and a reversible inferior thallium defect correlated with right coronary or left circumflex artery disease (p less than 0.0001). In patients with single vessel disease, the site of S-T segment depression does not identify the obstructed coronary artery; S-T segment elevation in lead V1 or aVL, or both, identifies left anterior descending coronary artery disease; and the site of reversible perfusion defect on thallium scanning identifies the site of myocardial ischemia and the obstructed coronary artery

  6. Cardiac events in patients with positive exercise ECG and normal myocardial perfusion scan - a retrospective study

    International Nuclear Information System (INIS)

    Marshman, K.; Thomson, L.E.J.; Rowe, C.C.; Burns, A.J.; Woon, F.S.

    2002-01-01

    Full text: The low risk of future cardiac events following a normal myocardial perfusion study with normal stress ECG has been well documented. However, there is little literature regarding the prognosis in patients with a positive stress ECG (PosETT) and normal myocardial perfusion scan (MPS). A search of our database over an eighteen month period identified 21 patients who fitted study criteria. A PosETT was defined as stress induced horizontal or downsloping ST depression > 1mm in one or more leads with a normal baseline 12 lead ECG. Patients were divided into two subgroups depending on the severity of ST depression. A mildly PosETT was defined as ST depression of 1-1.5mm (n=10) and strongly PosETT was defined as ST depression of >2mm in at least one lead with depression in other leads (n=l 1). A normal MPS was defined as absence of reversible perfusion defects on SPECT imaging. Technetium 99m Tetrofosmin was the imaging agent used in 18/21 patients. All 21 patients exercised using the Bruce protocol for 3-12 minutes, and 9 experienced chest pain 12 months after the MPS, referring physicians were contacted. Cardiac events were defined as cardiac death, myocardial infarction, unstable angina, cardiac failure, revascularisation or a coronary angiogram demonstrating >70% stenosis. To date, follow up is complete in 11 patients with one confirmed case of single vessel revascularisation 3 months post MPS. Full follow up data will be presented. Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  7. Reverse re-distribution in the myocardial perfusion scan with 201 Ti

    International Nuclear Information System (INIS)

    Eftekhari, M.; Sadeghi, R.; Fard-Esfahani, A.; Beiki, D.; Fallahi, B.; Saghari, M.

    2004-01-01

    Reverse re-distribution pattern id defined as decreased activity in the myocardium in the rest phase of the myocardial perfusion scan in comparison with the stress images. There are many studies concerning the etiology and clinical significance of this phenomenon in nuclear medicine literature. The dominant idea about etiology of reserve redistribution is early wash out of the radiotracer from the myocardium. There is rather unanimous agreement among researchers about viability of the areas of reverse redistribution and the majority of the studies point to existence of viable tissue in these regions. However from prognostic point of view, this issue is much more controversial. In this review, we tried to summarize the current literature and reach a guideline for practical significance of reverse redistribution in every day work of nuclear medicine specialists

  8. Technetium myocardial perfusion scanning in prerenal transplant evaluation in the United kingdom.

    LENUS (Irish Health Repository)

    Wong, C F

    2008-06-01

    Because death with a functioning graft remains one of the most important causes of long-term renal transplant failure, cardiac risk stratification and screening for coronary artery disease are essential components of pretransplant assessment. Pretransplant screening for occult coronary artery disease in a subset of these patients may improve outcome. The UK follows the European Best practice guideline 1.5.5 E. Although echocardiography, thallium myocardial perfusion scanning (MPS), dobutamine stress echocardiography, and coronary angiography have been suggested as means of cardiovascular assessment, the best means of assessment remains undetermined. Therefore, we investigated the role of 99m technetium sestamibi myocardial perfusion scanning as an assessment tool for identifying those patients with end-stage renal failure at high risk of cardiovascular death after renal transplantation. Retrospectively, we studied 126 patients that had a MPS as part of their pretransplant assessment. Overall unadjusted survival was 65% at 3 years. Twelve deaths resulted from cardiovascular causes. A reversible defect on MPS was associated with a fatal cardiac event and all-cause mortality. The unadjusted hazard ratio of cardiac event with reversible defect on MPS was 3.1 (95% confidence interval, 1.1 to 18.2) and hazard ratio of death with reversible defect on MPS was 1.92 (95% confidence interval, 1.1 to 4.4). Thus, MPS may be a useful tool in cardiac risk stratification and in selecting patients with a favorable outcome after renal transplantation. Our patients with a reversible defect in particular have increased cardiac mortality. This group may benefit from coronary angiography.

  9. Automated calculation of myocardial external efficiency from a single 11C-acetate PET/CT scan

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    of this study was to develop and validate an automated method of calculating MEE from a single dynamic 11C-acetate PETscan. Methods: 21 subjects underwent a dynamic 27 min 11C-acetate PETscan on a Siemens Biograph TruePoint 64 PET/CTscanner. Using cluster analysis, the LV-aortic time-activity curve (TACLV......). Conclusion: Myocardial efficiencycanbe derived directly andautomatically froma single dynamic 11C-acetate PET scan. This eliminates the need for a separate CMR scan and eliminates any potential errors due to different loading conditions between CMR and PETscans.......Background: Dynamic PETwith 11C-acetate can be used to assess myocardial oxygen use which in turn is usedto calculate myocardial external efficiency (MEE), anearly marker of heart failure. MEE is defined as the ratio of total work (TW) and total energy use (TE). Calculation of TW and TE requires...

  10. Myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bunko, Hisashi; Hisada, Kinichi

    1982-01-01

    Among the various methods of image diagnosis of the cardiovascular disorder, nuclear cardiology provides noninvasive means for evaluation of myocardial perfusion as well as morphological and functional informations. In this article, clinical application and image diagnosis of myocardial scintigraphy including Tl-201 myocardial perfusion scintigraphy, single photon emission computed tomography with Tl-201, acute myocardial infarction scintigraphy with Tc-99m-pyrophosphate and Ga-67 imaging of the heart, were discussed. Multiplanar imaging of the heart with Tl-201 after stress and at redistribution was the accepted method for detection and evaluation of the ischemic heart disease. Although it achieved high sensitivity and specificity for ischemic heart disease, detection of the small ischemia and quantation of the regional Tl-201 accumulation were difficult with conventional multiplanar imaging. Application of emission computed tomography improved detectability and quantitativity of the ischemia. However, 7-pinhole tomography did not increase the diagnostic accuracy significantly. It had limited clinical applicability due to poor quantitativity in spite of improved image contrast and its tomographic nature. Advantage and limitation of these tomographic imaging and multiplanar imaging were discussed. Problems and prognostic significance of pyrophosphate imaging of the acute myocardial infarction were also discussed. Visualization of the heart with Ga-67 was helpful for identification of the tumor or inflammation of the heart as well as evaluation of the effect of the therapy. (author)

  11. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Marcela Dias; Aguillera, André Haraguti [Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Brilhante, José Joaquim; Caixeta, Adriano [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export{sup ™} catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta{sup ™} FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation.

  12. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    International Nuclear Information System (INIS)

    Borges, Marcela Dias; Aguillera, André Haraguti; Brilhante, José Joaquim; Caixeta, Adriano

    2013-01-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export"™ catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta"™ FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation

  13. Role of stress myocardial perfusion SPECT scan in detection and management of coronary artery disease: Nairobi experience

    International Nuclear Information System (INIS)

    Makhdomi, K.B.; Warshow, M.M.; Patel, P.K.J.; Shah, D.; Githegi, D.R.M.

    2002-01-01

    Aim: Stress myocardial perfusion scans have acquired a significant role in the detection and management of Coronary Artery Disease. However, this mode of investigation has only recently been available in Nairobi, and this is the first such study from East Africa. We undertook a comparison of our results with that in the literature, to see whether they conformed to it. Materials and Methods: We performed a review of our initial 82 evaluable studies. The scans were performed with 99mTc-Tetrofosmin, using the single day stress-rest protocol with SPECT acquisitions. We carried out a correlation of our scan findings with angiographic data (where available), and clinical follow-up. The clinical end points where furnished by the referring physicians. We focused on myocardial infarction, need for re-vascularisation, and death. The mean clinical follow-up was 21.8 months (range of 12 months to 39 months). Results: Eighty (98%) of the studies revealed concordance with angiographic findings and/or were predictive of clinical outcome. Two studies were discordant, and will be discussed. The results are comparable with those in the literature. Conclusion: It is concluded that stress myocardial perfusion studies, done at our Centre, had a good predictive value, with regards to the presence and severity of disease, and correlated with the clinical outcome data

  14. Scintigraphy with /sup 111/In-labeled antimyosin F(ab)/sub 2/ monoclonal antibody and /sup 99m/Tc-pyrophosphate in rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T.; Schuemichen, C.; Hohenloser, S.; Kasper, W.; Meinertz, T.

    1988-02-01

    A report is presented of the scintigraphic diagnosis of a generalized rhabdomyolysis with myocardial involvement using /sup 111/In labelled antimyosin F(ab)/sub 2/ monoclonal antibodies as compared to /sup 99m/Tc pyrophosphate.

  15. Myocardial infarction

    International Nuclear Information System (INIS)

    Ando, Jyoji; Yasuda, Hisakazu; Miyamoto, Atsushi; Kobayashi, Tsuyoshi

    1980-01-01

    sup(99m)Tc-pyrophosphate (PYP) scintigraphy and 201 Tl myocardial scintigraphy were utilized for the diagnoses of the presence, the region, and the extent of myocardial infarction. Exercise 201 Tl myocardial scintigrams and exercise radionuclide ventriculography were utilized for diagnosis of coronary artery lesions in angina pectoris. Radionuclide ventriculography was used to investigate effects of coronary artery lesions on cardiac function and hemodynamics. In order to select adequate treatments for myocardial infarction and estimate the prognosis, it was necessary to detect the presence, the region, and the extent of acute myocardial infarction and to investigate effects of partial infarction on hemodynamics by using radionuclide imaging. Exercise myocardial scintigraphy could be carried out noninvasively and repeatedly for diagnosis of coronal artery disease. Therefore, this method could be applied widely. It was possible to use this method as a screening test of coronary artery diseases for the diagnoses of asymptomatic patients who showed ST changes in ECG, the patients with cardiac neurosis and the patency after a reconstructive surgery of coronary artery. (Tsunoda, M.)

  16. Study on thallium-201 myocardial perfusion scanning for detection of right ventricular hypertrophy in chronic pulmonary disease

    International Nuclear Information System (INIS)

    Kawai, Seiki

    1980-01-01

    Thallium-201 myocardial perfusion scanning was performed in 34 patients with chronic pulmonary disease for the purpose of detecting right ventricular hypertrophy. Thallium-201 activity ratio of left ventricle plus ventricular septum/right ventricle (TAR) was significantly correlated with hemodynamic findings such as pulmonary arterial mean pressure (r = -0.75, p 2 (p < 0.001). Assuming that TAR < 2 or TAR = 2 would indicate pulmonary hypertension, sensitivity was 95%, specificity 79%, validity score 75%, false positive 14% and false negative was 8%. TAR was compared with left to right ventricular mass ratio using Fulton's method in 6 autopsied patients in whom thallium-201 myocardial perfusion scanning were performed within three months before death. TAR closely correlated with left to right ventricular mass ratio (r = 0.978, p < 0.001). The comparison of validity of TAR with those of electrocardiographic interpretation according to WHO, Sasamoto, Roman or Milnor for the detection of right ventricular hypertrophy revealed the former was much superior to all of latters. From the results obtained, it may be inferred that TAR reflects the degree of pulmonary hypertension and anatomical right ventricular hypertrophy and is a useful non-invasive method to detect right ventricular hypertrophy in chronic pulmonary disease. (J.P.N.)

  17. Synthesis and thermal behavior of double copper and potassium pyrophosphate

    International Nuclear Information System (INIS)

    Ciopec, Mihaela; Muntean, Cornelia; Negrea, Adina; Lupa, Lavinia; Negrea, Petru; Barvinschi, Paul

    2009-01-01

    This paper presents the synthesis and thermal behavior of double copper and potassium pyrophosphate, which can be used as a PK fertilizer containing copper as micronutrient. In order to find the conditions for the synthesis of this compound from copper sulphate and potassium pyrophosphate, various Cu 2+ :P 2 O 7 4- molar ratios (0:1-2:1), various molar concentrations of the solutions (0.075; 0.1; 0.15 and 0.2 mol L -1 ) and various temperatures (25, 50, 75 and 100 o C) have been used. The solid product synthesized in optimum conditions for the separation of micronutrient copper from the reaction mass (Cu 2+ :P 2 O 7 4- molar ratio 1:1, concentration 0.1 mol L -1 ) was subjected to a complex study: chemical analysis, thermal analysis, energy dispersive X-ray spectroscopy, scanning electron microscopy and X-ray diffractometry. During heating up to 1000 o C, K 2 Cu 3 (P 2 O 7 ) 2 .3H 2 O loses the crystallization water; several transformations of the phosphates also take place: the decomposition of pyrophosphates to ortho-phosphates; the transformation of ortho-phosphates; the polymerization of a fraction of ortho-phosphates to amorphous phosphates with longer chains; the reorganization of ortho-phosphates and poly-phosphates to pyrophosphates and their crystallization. The decomposition mechanism was confirmed when using the X-ray diffraction patterns of the compound, thermally treated at several temperatures.

  18. Tl-201 myocardial perfusion scanning in patients with right bundle branch block coronary artery disease

    International Nuclear Information System (INIS)

    Shirani, J.; Malpani, A.R.; Blend, M.J.; Bekerman, C.

    1990-01-01

    This paper evaluates the specificity of stress T1-201 myocardial perfusion studies (T1-201 MPS) for coronary artery disease (CAD) in patients with right bundle branch block (RBBB). Twenty-four patients with RBBB and atypical chest pain with ECG findings limited to RBBB, adequate stress test (ie, >85% of maximal heart rate for age), and no clinical, hemodynamic, or ECG evidence of ischemia during exercise underwent T1-201 MPS. These perfusion patterns were compared with an equal number of age- and gender-matched controls with a normal ECG who met all other criteria mentioned above. Patients with RBBB showed a significantly higher frequency of reversible inferoposterior T1-201 defects (62.5% vs 20.8%)

  19. Acute myocardial infarction with a non-diagnostic electrocardiogram. Case presentation and overview

    Energy Technology Data Exchange (ETDEWEB)

    Przybojewski, J Z; Gilburt, S G.M. [Tygerberg Hospital, Stellenbosch (South Africa). Dept. of Internal Medicine

    1983-12-17

    The clinical presentation of a young hypertensive White man with acute high lateral non-transmural myocardial infarction (MI) is documented. This diagnosis was established on the grounds of a history of chest pain, elevated serial serum enzyme levels, technetium-99m pyrophosphate ('hot-spot') scintigraphy, exercise thallium-201 ('cold-spot') scanning, left ventricular cine angiography and selective coronary arteriography. Daily resting 12-lead ECGs failed to demonstrate unequivocal features of acute non-transmural subendocardial MI. The diagnostic difficulties facing the clinician in a case of acute MI associated with a non-diagnostic ECG are stressed, and the ECG features of acute subendocardial MI are reviewed.

  20. Rapid computation of single PET scan rest-stress myocardial blood flow parametric images by table look up.

    Science.gov (United States)

    Guehl, Nicolas J; Normandin, Marc D; Wooten, Dustin W; Rozen, Guy; Ruskin, Jeremy N; Shoup, Timothy M; Woo, Jonghye; Ptaszek, Leon M; Fakhri, Georges El; Alpert, Nathaniel M

    2017-09-01

    We have recently reported a method for measuring rest-stress myocardial blood flow (MBF) using a single, relatively short, PET scan session. The method requires two IV tracer injections, one to initiate rest imaging and one at peak stress. We previously validated absolute flow quantitation in ml/min/cc for standard bull's eye, segmental analysis. In this work, we extend the method for fast computation of rest-stress MBF parametric images. We provide an analytic solution to the single-scan rest-stress flow model which is then solved using a two-dimensional table lookup method (LM). Simulations were performed to compare the accuracy and precision of the lookup method with the original nonlinear method (NLM). Then the method was applied to 16 single scan rest/stress measurements made in 12 pigs: seven studied after infarction of the left anterior descending artery (LAD) territory, and nine imaged in the native state. Parametric maps of rest and stress MBF as well as maps of left (f LV ) and right (f RV ) ventricular spill-over fractions were generated. Regions of interest (ROIs) for 17 myocardial segments were defined in bull's eye fashion on the parametric maps. The mean of each ROI was then compared to the rest (K 1r ) and stress (K 1s ) MBF estimates obtained from fitting the 17 regional TACs with the NLM. In simulation, the LM performed as well as the NLM in terms of precision and accuracy. The simulation did not show that bias was introduced by the use of a predefined two-dimensional lookup table. In experimental data, parametric maps demonstrated good statistical quality and the LM was computationally much more efficient than the original NLM. Very good agreement was obtained between the mean MBF calculated on the parametric maps for each of the 17 ROIs and the regional MBF values estimated by the NLM (K 1map LM  = 1.019 × K 1 ROI NLM  + 0.019, R 2  = 0.986; mean difference = 0.034 ± 0.036 mL/min/cc). We developed a table lookup method for fast

  1. Photoaffinity labeling of undecaprenyl pyrophosphate synthetase with a farnesyl pyrophosphate analogue

    International Nuclear Information System (INIS)

    Baba, T.; Muth, J.; Allen, C.M.

    1985-01-01

    The prenyl transferase undecaprenyl pyrophosphate synthetase was partially purified from the cytosolic fraction of Escherichia coli. Its enzymic products were characterized as a family of cis-polyprenyl phosphates, which ranged in carbon number from C55 to C25. The enzyme is constituted of two subunits of approximately 30,000 molecular weight. A radiolabeled photolabile analogue of t,t-farnesyl pyrophosphate, [ 3 H]2-diazo-3-trifluoropropionyloxy geranyl pyrophosphate, was shown to label Lactobacillus plantarum and E. coli undecaprenyl pyrophosphate synthetase on UV irradiation in the presence of isopentenyl pyrophosphate and divalent cations. The only labeled polypeptide migrated on electrophoresis in a sodium dodecyl sulfate-polyacrylamide gel at a molecular weight of approximately 30,000. No protein was radiolabeled when the natural substrate, t,t-farnesyl pyrophosphate was included in the irradiation mixture. Irradiation in the presence of MgCl 2 without isopentenyl pyrophosphate gave less labeling of the polypeptide. Irradiation with only isopentenyl pyrophosphate gave little labeling of the polypeptide. When the enzyme was irradiated with 3H-photoprobe, [ 14 C]isopentenyl pyrophosphate, and MgCl 2 , the labeled polypeptide gave a ratio of 14 C/ 3 H that indicated the product must also bind to the enzyme on irradiation. These results demonstrate the ability to radiolabel the allylic pyrophosphate binding site and possibly product binding site of undecaprenyl pyrophosphate synthetase by a process which is favored when both cosubstrate and divalent cations are present

  2. Ressonância magnética vs cintilografia com pirofosfato marcado com tecnécio-99m para a detecção de necrose miocárdica perioperatória Magnetic resonance vs technetium-99m pyrophosphate scintigraphy in the detection of perioperative myocardial necrosis

    Directory of Open Access Journals (Sweden)

    Guilherme Urpia Monte

    2008-08-01

    Full Text Available FUNDAMENTO: O infarto do miocárdio perioperatório (IMPO é uma complicação da cirurgia de revascularização miocárdica (CRM com potencial impacto prognóstico. A cintilografia miocárdica (CM com pirofosfato marcado com tecnécio-99m é utilizada no diagnóstico de IMPO, mas demonstra limitada sensibilidade para lesões subendocárdicas. A ressonância magnética cardiovascular (RMC, por sua vez, detém alta acurácia para a detecção de necrose miocárdica. OBJETIVO: Comparar a RMC e a CM para a detecção de IMPO após CRM. MÉTODOS: Foram estudados 24 pacientes portadores de doença arterial coronária crônica, com a técnica de realce tardio pela RMC e com a CM, antes e depois da CRM, analisando-se o surgimento de áreas de necrose miocárdica perioperatória (IMPO. Mensuraram-se também marcadores bioquímicos de lesão miocárdica (CKMB e troponina I, antes e depois da cirurgia. RESULTADOS: Dezenove pacientes completaram o estudo. Desses, 6 (32% apresentaram IMPO à RMC, e 4 (21% à CM (p = NS. Dos 323 segmentos do ventrículo esquerdo avaliados, 17 (5,3% exibiram necrose perioperatória à RMC, e 7 (2,2% à CM (p = 0,013. Observou-se moderada concordância entre os métodos (kappa = 0,46, havendo divergência, quanto ao diagnóstico de IMPO, em 4 (21% casos, a maioria com pequenas áreas de necrose perioperatória à RMC, não visualizadas à CM. Em todos os casos com IMPO à RMC, houve elevação significativa de CKMB e troponina I. CONCLUSÃO: Houve moderada concordância diagnóstica entre os métodos para a detecção de IMPO, mas a RMC permitiu a visualização de pequenas áreas de necrose miocárdica perioperatória, não identificadas pela CM e associadas à elevação de marcadores bioquímicos de lesão miocárdica.BACKGROUND: Perioperative myocardial infarction (POMI is a complication of coronary artery bypass grafting (CABG with a potential prognostic impact. Technetium-99m pyrophosphate myocardial scintigraphy (MS is

  3. Familial pyrophosphate arthropathy. Occurrence and Crystal Identification.

    Science.gov (United States)

    Bjelle, A

    1981-01-01

    Hereditary pyrophosphate arthropathy has been observed in three Swedish families and in a few other caucasian populations. The inheritance is most probably autosomal dominant with a variable penetrance. The most severe cases have been found in homozygotes among isolates of immigrants in Slovakia and Chile. Studies on genetic and etio-pathogenetic factors in hereditary pyrophosphate arthropathy, and the utilization of new diagnostic techniques for crystal identification, are important approaches towards a further understanding of the disease.

  4. Visualization of rhabdomyolysis with scintigraphy with Tc99m pyrophosphate: presentation of a clinical case

    International Nuclear Information System (INIS)

    Pruzzo C, Rossana; Amaral P, Horacio; Morales K, Barbara; Hurtado, Ester

    2000-01-01

    We present a case of secondary rhabdomyolysis due to vascular ischemia after dissection of the proximal aorta and obstruction of the left femoral artery after cocaine consumption. A Tc99m-pyrophosphate whole body scan demonstrated the presence of rhabdomyolysis in both lower extremities (Au)

  5. Use of myocardial imaging in the evaluation of patients with cardiovascular disease

    Energy Technology Data Exchange (ETDEWEB)

    Pitt, B.; Strauss, H.W.; Trhall, J.H.

    1980-01-01

    The role of radioisotope tracer techniques in the evaluation of patients with congenital heart disease, valvular heart disease, suspected myocardial infarction, ischemia or suspected ventricular dysfunction is reviewed. Thallium-201 myocardial imaging and exercise blood pool imaging and Technetium-88m pyrophosphate imaging of myocardial infarction are most commonly used.

  6. Concordance between myocardial perfusion scan assessed by SPECT and fractional flow reserve findings for detection of significant ischemia

    Directory of Open Access Journals (Sweden)

    Morteza Safi

    2016-09-01

    Conclusion: FFR and MPI with SPECT techniques showed significant concordance for detection of myocardial ischemia, regardless of the type of diseased coronary arteries. In this context, SPECT has high sensitivity and NPV for detection of ischemia compared with FFR.

  7. Normal myocardial perfusion scan portends a benign prognosis independent from the pretest probability of coronary artery disease. Sub-analysis of the J-ACCESS study

    International Nuclear Information System (INIS)

    Imamura, Yosihiro; Fukuyama, Takaya; Nishimura, Sigeyuki; Nishimura, Tsunehiko

    2009-01-01

    We assessed the usefulness of gated stress/rest 99mTc-tetrofosmin myocardial perfusion single photon emission computed tomography (SPECT) to predict ischemic cardiac events in Japanese patients with various estimated pretest probabilities of coronary artery disease (CAD). Of the 4031 consecutively registered patients for a J-ACCESS (Japanese Assessment of Cardiac Events and Survival Study by Quantitative Gated SPECT) study, 1904 patients without prior cardiac events were selected. Gated stress/rest myocardial perfusion SPECT was performed and segmental perfusion scores and quantitative gated SPECT results were derived. The pretest probability for having CAD was estimated using the American College of Cardiology/American Heart Association/American College of Physicians- American Society of Internal Medicine guideline data for the management of patients with chronic stable angina, which includes age, gender, and type of chest discomfort. The patients were followed up for three years. During the three-year follow-up period, 96 developed ischemic cardiac events: 17 cardiac deaths, 8 nonfatal myocardial infarction, and 71 clinically driven revascularization. The summed stress score (SSS) was the most powerful independent predictor of all ischemic cardiac events (hazard ratio 1.077, confidence interval (CI) 1.045-1.110). Abnormal SSS (>3) was associated with a significantly higher cardiac event rate in patients with an intermediate to high pretest probability of CAD. Normal SSS (≤3) was associated with a low event rate in patients with any pretest probability of CAD. Myocardial perfusion SPECT is useful for further risk-stratification of patients with suspected CAD. The abnormal scan result (SSS>3) is discriminative for subsequent cardiac events only in the groups with an intermediate to high pretest probability of CAD. The salient result is that normal scan results portend a benign prognosis independent from the pretest probability of CAD. (author)

  8. Ceramics based on calcium pyrophosphate nanopowders

    Directory of Open Access Journals (Sweden)

    Tatiana V. Safronova

    2013-03-01

    Full Text Available Present work is aimed at the fabrication of resorbable bioceramics based on calcium pyrophosphate (CPP from the synthesized powders of amorphous hydrated calcium pyrophosphate (AHCPP. Amorphous hydratedcalcium pyrophosphate in the form of nanopowders was precipitated from Ca(NO3 2 and (NH4 4P2O7 solutions at room temperature in the presence of PO3– ions. Crystalline CPP powder was fabricated from AHCPP by its thermal decomposition at 600 °C and consisted of β- and α- phase. Small particles, with the size less than 200 nm, were formed promoting sintering of the ceramic material. The final sample, sintered at 900 °C, exhibits microstructure with submicron grains, apparent density of 87% of theoretical density (TD and demonstrates tensile strength of 70 MPa.

  9. Preparation of cerium doped calcium pyrophosphate: Study of luminescent behavior

    Energy Technology Data Exchange (ETDEWEB)

    Lozano, I.B., E-mail: ivonne.berenice@gmail.com [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Roman-Lopez, J. [CONACYT Research Fellow-Instituto de Ciencias Nucleares, Universidad Nacional Autónoma de México, A.P. 70-543, 04510 México D.F., México (Mexico); Sosa, R. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico); Díaz-Góngora, J.A.I [Instituto Politécnico Nacional, Centro de Investigación en Ciencia Aplicada y Tecnología Avanzada, Unidad Legaria, 11500 México D.F., México (Mexico); Azorín, J. [Departamento de Física, Universidad Autónoma Metropolitana-Iztapalapa, 09340 México D.F., México (Mexico)

    2016-05-15

    Thermoluminescent (TL) and photoluminescent (PL) band emissions of cerium doped calcium pyrophosphate (Ca{sub 2}O{sub 7}P{sub 2}:Ce{sup 3+}) were studied. Wet precipitation method was used to synthesize calcium pyrophosphate, doped with Ce{sup 3+} (1.0 at%) impurities, from orthophosphoric acid and calcium acetate, as raw materials. The effect of temperature annealing at 800 and 900 °C was investigated. X-Ray diffraction (XRD) and Scanning Electron Microscope (SEM) were used to characterize both as-precipitated and annealed powders samples. The PL emission spectrum of samples annealed at 900 °C displayed characteristics 5d–4f transitions of Ce{sup 3+} at 333 nm and 360 nm. TL measurements were carried out on as-precipitated and annealed samples from room temperature (RT) up to 350 °C. The TL results of annealed samples showed complex TL glow curves, a linear response in the absorbed dose range of 0.5–5 Gy and a good reproducibility after 10 cycles of irradiation-readout. The complex TL glow curves of annealed samples were analyzed by the methods of T{sub max}–T{sub Stop}, Initial Rise (IR) and Computational Glow-Curve Deconvolution (CGCD) assuming a General Order Kinetic (GOK).

  10. Myocardial perfusion imaging and coronary calcium scoring with a two-slice SPECT/CT system: can the attenuation map be calculated from the calcium scoring CT scan?

    Energy Technology Data Exchange (ETDEWEB)

    Wenning, Christian; Rahbar, Kambiz; Schober, Otmar; Stegger, Lars [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); Vrachimis, Alexis; Schaefers, Michael [University of Muenster, Department of Nuclear Medicine, Muenster (Germany); University of Muenster, European Institute for Molecular Imaging, Muenster (Germany)

    2013-07-15

    Coronary artery calcium scoring can complement myocardial perfusion imaging (MPI). The purpose of this study was to evaluate the feasibility and accuracy of using the CalciumScore-CT derived from a combined SPECT/CT device also for SPECT attenuation correction (AC). The study group comprised 99 patients who underwent both post-stress and rest MPI using a two-slice SPECT/CT system. For AC, one of the two scans was accompanied by a CalciumScore-CT scan (CalciumScore-CTAC) and the other by a conventional spiral CT (AttenCorr-CT) scan (AttenCorr-CTAC). In 48 patients the CalciumScore-CT scan was acquired with the post-stress scan and the AttenCorr-CT scan with the rest scan, and in 51 patients the order was reversed. The accuracy of the images based on AC was determined qualitatively by consensus reading with respect to the clinical diagnoses as well as quantitatively by comparing the perfusion summed stress scores (SSS) and the summed rest scores (SRS) between attenuation-corrected and uncorrected images. In comparison to the uncorrected images CalciumScore-CTAC led to regional inaccuracies in 14 of 51 of studies (27.5 %) versus 12 of 48 studies (25 %) with AttenCorr-CTAC for the stress studies and in 5 of 48 (10 %) versus 1 of 51 (2 %) for the rest studies, respectively. This led to intermediate and definite changes in the final diagnosis (ischaemia and/or scarring) in 12 % of the studies (12 of 99) and in 7 % of the studies (7 of 99) with CalciumScore-CTAC and in 9 % of the studies (9 of 99) and 4 % of the studies (4 of 99) with AttenCorr-CTAC. Differences in SSS and SRS with respect to the uncorrected images were greater for the CalciumScore-CTAC images than for the AttenCorr-CTAC images ({Delta}SSS 4.5 {+-} 5.6 and 2.1 {+-} 4.4, p = 0.023; {Delta}SRS 4.2 {+-} 4.9 and 1.6 {+-} 3.2, p = 0.004, respectively). Using the same CT scan for calcium scoring and SPECT AC is feasible. Image interpretation must, however, include uncorrected images since CT-based AC relatively

  11. Future cardiac events in patients with ischemic ECG changes during adenosine infusion as a myocardial stress agent and normal cardiac scan.

    Science.gov (United States)

    Amer, Hamid; Niaz, Khalid; Hatazawa, Jun; Gasmelseed, Ahmed; Samiri, Hussain Al; Al Othman, Maram; Hammad, Mai Al

    2017-11-01

    We sought to determine the prognostic importance of adenosine-induced ischemic ECG changes in patients with normal single-photon emission computed tomography myocardial perfusion images (MPI). We carried out a retrospective analysis of 765 patients undergoing adenosine MPI between January 2013 and January 2015. Patients with baseline ECG abnormalities and/or abnormal scan were excluded. Overall, 67 (8.7%) patients had ischemic ECG changes during adenosine infusion in the form of ST depression of 1 mm or more. Of these, 29 [43% (3.8% of all patients)] had normal MPI (positive ECG group). An age-matched and sex-matched group of 108 patients with normal MPI without ECG changes served as control participants (negative ECG group). During a mean follow-up duration of 33.3±6.1 months, patients in the positive ECG group did not have significantly more adverse cardiac events than those in the negative ECG group. One (0.9%) patient in the negative ECG group had a nonfatal myocardial infarction (0.7% annual event rate after a negative MPI). Also in this group, two (1.8%) patients admitted with a diagnosis of CAD where they have been ruled out by angiography. A fourth case in this, in the negative ECG group, was admitted because of heart failure that proved to be secondary to a pulmonary cause and not CAD. A case only in the positive ECG group was admitted as a CAD that was ruled out by coronary angiography. Patients with normal myocardial perfusion scintigraphy in whom ST-segment depression develops during adenosine stress test appear to have no increased risk for future cardiac events compared with similar patients without ECG evidence of ischemia.

  12. Heart PET scan

    Science.gov (United States)

    ... nuclear medicine scan; Heart positron emission tomography; Myocardial PET scan ... A PET scan requires a small amount of radioactive material (tracer). This tracer is given through a vein (IV), ...

  13. Myocardial imaging in coronary heart disease with radionuclides, with emphasis on thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Wackers, F J.Th.; Sokole, E B; Samson, G; van der Schoot, J B; Wellens, H J.J. [Amsterdam Univ. (Netherlands). Academisch Ziekenhuis

    1976-09-01

    During the past few years there has been an increasing interest in cardiology for myocardial imaging with radionuclides. At present the experience with both negative (thallium-201) and positive (sup(99m)Tc-pyrophosphate) imaging of myocardial infarction is increasing rapidly. Since 1974, over 1100 patient studies with thallium-201 were performed. In this article a survey is presented of experience with thallium-201 in patients with acute and chronic coronary artery disease. In patients with acute myocardial infarction data from studies with sup(99m)Tc-pyrophosphate will be discussed as well.

  14. Rapid dual-injection single-scan 13N-ammonia PET for quantification of rest and stress myocardial blood flows

    International Nuclear Information System (INIS)

    Rust, T C; DiBella, E V R; McGann, C J; Christian, P E; Hoffman, J M; Kadrmas, D J

    2006-01-01

    Quantification of myocardial blood flows at rest and stress using 13 N-ammonia PET is an established method; however, current techniques require a waiting period of about 1 h between scans. The objective of this study was to test a rapid dual-injection single-scan approach, where 13 N-ammonia injections are administered 10 min apart during rest and adenosine stress. Dynamic PET data were acquired in six human subjects using imaging protocols that provided separate single-injection scans as gold standards. Rest and stress data were combined to emulate rapid dual-injection data so that the underlying activity from each injection was known exactly. Regional blood flow estimates were computed from the dual-injection data using two methods: background subtraction and combined modelling. The rapid dual-injection approach provided blood flow estimates very similar to the conventional single-injection standards. Rest blood flow estimates were affected very little by the dual-injection approach, and stress estimates correlated strongly with separate single-injection values (r = 0.998, mean absolute difference = 0.06 ml min -1 g -1 ). An actual rapid dual-injection scan was successfully acquired in one subject and further demonstrates feasibility of the method. This study with a limited dataset demonstrates that blood flow quantification can be obtained in only 20 min by the rapid dual-injection approach with accuracy similar to that of conventional separate rest and stress scans. The rapid dual-injection approach merits further development and additional evaluation for potential clinical use

  15. Comparison of Hemodynamic Effects and Negative Predictive Value of Normal Adenosine Gated Myocardial Perfusion Scan With or Without Caffeine Abstinence

    International Nuclear Information System (INIS)

    Zaman, Maseeh uz; Fatima, Nosheen; Zaman, Areeba; Zaman, Unaiza; Tahseen, Rabia

    2016-01-01

    For vasodilator stress, myocardial perfusion imaging (MPI) with at least 12-h caffeine abstinence is recommended, as it attenuates cardiovascular hyperemic response of adenosine and dipyridamole. However, many published conflicting results have shown no significant effect upon perfusion abnormalities in MPI performed without caffeine abstinence. The aim of this study was to compare the hemodynamic changes and negative predictive value (NPV) of normal MPIs with adenosine stress performed with or without caffeine abstinence. This was a prospective study that accrued 50 patients from May 2013 till September 2013 and followed till November 2014. These patients had a normal adenosine-gated MPI (GMPI) with technetium-99m methoxy isobutyl isonitrile ( 99m Tc-MIBI) after 12-h caffeine abstinence (no-caffeine). Next day, all patients had a repeat adenosine stress within 60 min after ingestion of a cup of coffee (about 80 mg of caffeine) followed by no MPI in 30 patients due to concern about radiation dose (prior-caffeine adenosine—no MPI; group A). Twenty patients opted for a repeat MPI (prior-caffeine adenosine—MPI; group B). Adenosine-induced hemodynamic response and NPV of the normal MPI with no-caffeine and prior-caffeine protocols were compared. The mean age of the study cohort was 57 ± 9 years with a male-to-female ratio of 76:24% and mean body mass index (BMI) of 26.915 ± 4.121 kg/m 2 . Prevalence of hypertension, diabetes, dyslipidemia, and positive family history were 76%, 20%, 22%, and 17%, respectively. Comparison of group A with group B revealed no significant difference in demographic parameters, hemodynamic or electrocardiography (ECG) parameters, or left ventricular (LV) function parameters during adenosine intervention with prior-caffeine and no-caffeine protocols. During the follow-up, no fatal myocardial infarction (MI) was reported but 6 nonfatal MIs were reported based upon the history of short hospitalization for chest pain but without biochemical

  16. Myocardial scintigraphy with thallium-201

    Energy Technology Data Exchange (ETDEWEB)

    Lichte, H [Zentralkrankenhaus Gauting (Germany, F.R.). Nuklearmedizinische Abt.

    1977-04-01

    Myocardial scintigraphy with /sup 201/thallium is a non-invasive method for detection of myocardial infarction and coronary heart disease. Redistribution-analysis as a sequential-scintigraphy of an exercise-scan permits to distinguish between myocardial scars and coronary vessel disease.

  17. Myocardial Bridge

    Science.gov (United States)

    ... Center > Myocardial Bridge Menu Topics Topics FAQs Myocardial Bridge En español Your heart is made of muscle, ... surface of the heart. What is a myocardial bridge? A myocardial bridge is a band of heart ...

  18. A novel approach towards the synthesis of pyrophosphate analogues of farnesyl pyrophosphate

    NARCIS (Netherlands)

    Valentijn, A.R.P.M.; Berg, O. van den; Marel, G.A. van der; Cohen, L.H.; Boom, J.H. van

    1994-01-01

    The synthesis of two new analogues (i.e. 3 and 4) of farnesyl pyrophosphate (FPP) containing a phosphonophosphate and a phosphonophosphonate moiety was accomplished via the phosphonomorpholidate. The latter was easily obtained by treatment of a phosphonic chloride with morpholine.

  19. Detection of metastatic bone cancer by scintiscanning with sup(99m)Tc labelled sodium pyrophosphate

    International Nuclear Information System (INIS)

    Kromer, Bernard.

    1973-01-01

    Bone scanning with sup(99m)Tc sodium pyrophosphate was performed in 65 patients with primary neoplasms, using a gamma-camera. The scans are compared to those obtained with 85 Sr and 87 Sr. Sup(99m)Tc appears to be superior to the other two in the detection of metastatic bone lesions, mainly because of its physical characteristics (high yield of 140 KeV photons, short physical half-life). The advantages related to these characteristics are emphasized: possibility of rapid and systematic investigation of the whole skeleton using a gamma-camera; low dose irradiation of the patient which enables frequent repetitive studies to be performed [fr

  20. Jointscintigraphy with 99m Tc-pyrophosphate

    International Nuclear Information System (INIS)

    Mirtl, B.; Leb, G.; Klein, G.; Goebel, R.; Eber, O.

    1975-01-01

    Joint scintigraphy was performed in 85 patients suffering from a variety of rheumatic diseases, using a gamma camera and line scanner. Tc-pyrophosphate was the radio nuclide employed; it accumulates selectively in the juxta-articular parts of the bone. The method provides an objective demonstration of inflammatory and degenerative rheumatic joint changes. More over scintigraphic changes can be demonstrated in joint disease which is too early to be clinically apparent or before there are any corresponding changes in serological parameters. The method is useful both in the localisation and staging of disease, in the evaluation of treatment and as an objective control of clinical skills. (orig.) [de

  1. Quantitative accuracy of denoising techniques applied to dynamic 82Rb myocardial blood flow PET/CT scans

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Bouchelouche, Kirsten

    with suspected ischemic heart disease underwent a dynamic 7 minute 82Rb scan under resting and adenosine induced hyperaemic conditions after injection of 1100 MBq of 82Rb on a GE Discovery 690 PET/CT. Dynamic images were filtered using HighlY constrained backPRojection (HYPR) and a Hotelling filter of which...... the latter was evaluated using a range of 4 to 7 included factors and for both 2D and 3D filtering. Data were analyzed using Cardiac VUer and obtained MBF values were compared with those obtained when no denoising of the dynamic data was performed. Results: Both HYPR and Hotelling denoising could...

  2. Case of myocardial abscess evaluated by radionuclide techniques: case report

    International Nuclear Information System (INIS)

    Spies, S.M.; Meyers, S.N.; Barresi, V.; Grais, I.M.; DeBoer, A.

    1977-01-01

    A patient with infective endocarditis was evaluated by Ga-67 citrate imaging, Tc-99m pyrophosphate imaging, equilibrium gated blood pool imaging, and Tl-201 imaging of the chest. The diagnosis of ventricular abscess was first suggested by an abnormal gallium scan. At surgery, an abscess was identified in the area where the scan was abnormal, and postoperatively a repeat scan was normal

  3. β-pyrophosphate: A potential biomaterial for dental applications

    Energy Technology Data Exchange (ETDEWEB)

    Anastasiou, A.D., E-mail: a.anastasiou@leeds.ac.uk [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Strafford, S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Posada-Estefan, O. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Thomson, C.L. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Hussain, S.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Cambridge Graphene Centre, Engineering Department, University of Cambridge, 9, JJ Thomson Avenue, Cambridge CB3 0FA (United Kingdom); Edwards, T.J. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Malinowski, M. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Hondow, N. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Metzger, N.K.; Brown, C.T.A. [SUPA, School of Physics and Astronomy, University of St Andrews, North Haugh, St Andrews, Fife KY16 9SS (United Kingdom); Routledge, M.N. [Leeds Institute of Cardiovascular and Metabolic Medicine, Faculty of Medicine and Health, University of Leeds, LS2 9JT (United Kingdom); Brown, A.P. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom); Duggal, M.S. [Leeds Dental School, Worsley Building, University of Leeds, Leeds LS2 9JT (United Kingdom); Jha, A. [School of Chemical and Process Engineering, University of Leeds, Leeds LS2 9JT (United Kingdom)

    2017-06-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  4. β-pyrophosphate: A potential biomaterial for dental applications

    International Nuclear Information System (INIS)

    Anastasiou, A.D.; Strafford, S.; Posada-Estefan, O.; Thomson, C.L.; Hussain, S.A.; Edwards, T.J.; Malinowski, M.; Hondow, N.; Metzger, N.K.; Brown, C.T.A.; Routledge, M.N.; Brown, A.P.; Duggal, M.S.; Jha, A.

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluate this densified mineral as a potential replacement material for dental hard tissue. To this end, we have tested the hardness of β-pyrophosphate pellets (sintered at 1000 °C) and its mineral precursor (brushite), the wear rate during simulated tooth-brushing trials and the cytocompatibility of these minerals in powder form. It was found that the hardness of the β-pyrophosphate pellets is comparable with that of dental enamel and significantly higher than dentine while, the brushing trials prove that the wear rate of β-pyrophosphate is much slower than that of natural enamel. Finally, cytotoxicity and genotoxicity tests suggest that iron doped β-pyrophosphate is cytocompatible and therefore could be used in dental applications. Taken together and with the previously reported results on laser irradiation of these materials we conclude that iron doped β-pyrophosphate may be a promising material for restoring acid eroded and worn enamel. - Highlights: • A novel procedure for the restoration of dental enamel is introduced. • Fe-doped ß-pyrophosphate is evaluated as potential biomaterial for enamel restoration. • Fe-doped ß-pyrophosphate found to have the same hardness as natural enamel and dramatically lower wear rate. • Cytotoxicity and genotoxicity tests suggest that Fe-doped ß-pyrophosphate is safe for dental applications.

  5. Postcountershock myocardial damage after pretreatment with adrenergic and calcium channel antagonists in halothane-anesthetized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Gaba, D.M.; Metz, S.; Maze, M.

    1985-05-01

    Transthoracic electric countershock can cause necrotic myocardial lesions in humans as well as experimental animals. The authors investigated the effect on postcountershock myocardial damage of pretreatment with prazosin, an alpha-1 antagonist; L-metoprolol, a beta-1 antagonist, and verapamil, a calcium channel-blocking agent. Twenty dogs were anesthetized with halothane and given two transthoracic countershocks of 295 delivered joules each after drug or vehicle treatment. Myocardial injury was quantitated 24 h following countershock by measuring the uptake of technetium-99m pyrophosphate in the myocardium. Elevated technetium-99m pyrophosphate uptake occurred in visible lesions in most dogs regardless of drug treatment. For each of four parameters of myocardial damage there was no statistically significant difference between control animals and those treated with prazosin, metoprolol, or verapamil. These data suggest that adrenergic or calcium channel-mediated mechanisms are not involved in the pathogenesis of postcountershock myocardial damage.

  6. OSTEOPOROSIS IN CALCIUM PYROPHOSPHATE CRYSTAL DEPOSITION DISEASE

    Directory of Open Access Journals (Sweden)

    S A Vladimirov

    2013-01-01

    Full Text Available Objective: to study the incidence of osteoporosis (OP in patients with calcium pyrophosphate crystal deposition disease (CPCDD. Subjects and methods. Eighty patients with CPCDD were examined. Bone mineral density (BMD of the forearm, lumbar spine, and femoral neck was determined by dual-energy X-ray absorptiometry. Laboratory diagnosis involved determination of the blood levels of C-reactive protein, parathyroid hormone, calcium, magnesium, and phosphorus and the daily urinary excretion of calcium and phosphates. Results. The patients with OP were significantly older than those with normal BMD and osteopenia. Forearm bones were the most common isolated location of OP and osteopenia. Injuries in the history, traumatic fractures, and the intake of diuretics were somewhat more common in the patients diagnosed with OP. The incidence of hyperparathyroidism did not differ significantly in the groups.

  7. Calcium pyrophosphate deposition disease: clinical manifestations

    Directory of Open Access Journals (Sweden)

    M.A. Cimmino

    2012-01-01

    Full Text Available Calcium pyrophosphate deposition (CPPD disease is an arthropathy caused by calcium pyrophosphate dihydrate (CPP crystal deposits in articular tissues, most commonly fibrocartilage and hyaline cartilage. According to EULAR, four different clinical presentations can be observed: 1 asymptomatic CPPD; 2 osteoarthritis (OA with CPPD; 3 acute CPP crystal arthritis; 4 chronic CPP inflammatory crystal arthritis. Acute CPP crystal arthritis is characterized by sudden onset of pain, swelling and tenderness with overlying erythema, usually in a large joint, most often the knee, wrist, shoulder, and hip. Occasionally, ligaments, tendons, bursae, bone and the spine can be involved. CPPD of the atlanto-occipital joint (crowned dens syndrome can cause periodic acute cervico-occipital pain with fever, neck stiffness and laboratory inflammatory syndrome. Chronic inflammatory arthritis is characterized by joint swelling, morning stiffness, pain, and high ESR and CRP. The relationship between OA and CPPD is still unclear. The main problem is whether such crystals are directly involved in the pathogenesis of OA or if they are the result of joint degeneration. Diagnosis is based on evaluation of history and clinical features, conventional radiology, and synovial fluid examination. Non-polarized light microscopy should be used initially to screen for CPPD crystals based upon their characteristic morphology, and compensated polarized light microscopy, showing the crystals to be weakly positive birefringent, is recommended for definitive identification, although this last pattern only occurs in about 20% of samples. The main goals of CPPD therapy are control of the acute or chronic inflammatory reaction and prevention of further episodes.

  8. Accuracy of localization of acute myocardial infarction by 12 lead electrocardiography

    International Nuclear Information System (INIS)

    Yasuda, T.; Ribeiro, L.G.; Holman, B.L.; Alpert, J.S.; Maroko, P.R.

    1982-01-01

    Until recently, ECG accuracy in localizing acute myocardial infarction (AMI) could be assessed only by comparing the ECGs with autopsy findings. This approach, however, preselected patients, including only those who died. It is possible that this postmortem group of patients would be different from the whole population of patients with AMI. Myocardial imaging with 99 mTc-pyrophosphate offers the advantage of directly localizing the region of injured myocardium in the acute phase of AMI. In 34 patients with confirmed AMI and focal uptake of 99 mTc-pyrophosphate, serial ECGs were obtained and interpreted by two independent observers. The sensitivity and specificity of serial ECGs in determining the location of AMI in the five left ventricular (LV) wall segments were determined: (1) in the anterior wall sensitivity was 86.7% and specificity was 89.5%; (2) in the lateral wall sensitivity was 73.7% and specificity was 80.0%; (3) in the high lateral wall sensitivity was 80.0% and specificity was 87.5%; (4) in the inferior wall sensitivity was 87.5% and specificity was 100%; (5) in the true posterior wall sensitivity was 83.3% and specificity was 86.4%. Overall, in the 170 LV wall segments (five per patient) examined, scans localized with a sensitivity of 81.9% and a specificity of 88.8%. After four patients with LBBB were excluded, sensitivity increased to 87.1%. Overall, localization of AMI by serial ECG was accurate in 85.9% of the 34 patients included in the study

  9. Calcium pyrophosphate dihydrate crystal deposition disease presenting as a pseudotumor of the temporomandibular joint

    International Nuclear Information System (INIS)

    Vargas, A.; Teruel, J.; Pont, J.; Velayos, A.; Trull, J.; Lopez, E.

    1997-01-01

    We report a case of a 66-year-old white woman with calcium pyrophosphate dihydrate (CPPD) crystal deposition disease. The patient related a 2-month history of swelling with tenderness over the left pre-auricular region. A CT scan suggested a synovial chondromatosis. Surgical removal was done and histologic study showed CPPD crystals. This disease rarely involves the temporomandibular joint (TMJ) and is not usually considered in the differential diagnosis. To our knowledge, only 14 cases have been reported in the literature. (orig.)

  10. Methanophosphagen: Unique cyclic pyrophosphate isolated from Methanobacterium thermoautotrophicum

    OpenAIRE

    Kanodia, Sushila; Roberts, Mary Fedarko

    1983-01-01

    A unique cyclic pyrophosphate compound has been detected at 10-12 mM intracellular concentration in Methanobacterium thermoautotrophicum by in vivo31P NMR. This compound has been extracted from cells and purified by anion-exchange chromatography. Studies with 1H, 13C, and 31P NMR and fast-atom-bombardment mass spectrometry have identified it as 2,3-cyclopyrophosphoglycerate, an intramolecularly cyclized pyrophosphate of 2,3-diphosphoglycerate. Chemical degradation to 2,3-diphosphoglycerate an...

  11. PLUTONIUM PURIFICATION PROCESS EMPLOYING THORIUM PYROPHOSPHATE CARRIER

    Science.gov (United States)

    King, E.L.

    1959-04-28

    The separation and purification of plutonium from the radioactive elements of lower atomic weight is described. The process of this invention comprises forming a 0.5 to 2 M aqueous acidffc solution containing plutonium fons in the tetravalent state and elements with which it is normally contaminated in neutron irradiated uranium, treating the solution with a double thorium compound and a soluble pyrophosphate compound (Na/sub 4/P/sub 2/O/sub 7/) whereby a carrier precipitate of thorium A method is presented of reducing neptunium and - trite is advantageous since it destroys any hydrazine f so that they can be removed from solutions in which they are contained is described. In the carrier precipitation process for the separation of plutonium from uranium and fission products including zirconium and columbium, the precipitated blsmuth phosphate carries some zirconium, columbium, and uranium impurities. According to the invention such impurities can be complexed and removed by dissolving the contaminated carrier precipitate in 10M nitric acid, followed by addition of fluosilicic acid to about 1M, diluting the solution to about 1M in nitric acid, and then adding phosphoric acid to re-precipitate bismuth phosphate carrying plutonium.

  12. Rationale and radiopharmaceuticals for myocardial imaging

    International Nuclear Information System (INIS)

    Poe, N.D.

    1976-01-01

    Static radionuclide imaging procedures are now available for evaluating regional myocardial perfusion and for detecting acute myocardial infarction. Thallium-201, a radiopharmaceutical which possesses many of the characteristics of potassium analogs, at present is receiving the greatest attention as a regional blood flow indicator. Ischemic lesions appear as areas of decreased tracer uptake. Unfortunately, this agent is expensive, is in limited supply and has a photopeak which is low for optimum imaging. Positive infarct images can be obtained with various technetium-99m chelates. Pyrophosphate appears to be the best of the technetium compounds studied to date although the mechanism of uptake of the chelates has not yet been fully elucidated. Therefore, quantitative measurements of infarct size are not justified. As perfusion imaging and infarct imaging provide useful, complementary data, a dual tracer approach to evaluating patients with suspected coronary artery disease and/or myocardial infarction is probably justifiable

  13. Sodium pyrophosphate enhances iron bioavailability from bouillon cubes fortified with ferric pyrophosphate.

    Science.gov (United States)

    Cercamondi, Colin I; Duchateau, Guus S M J E; Harika, Rajwinder K; van den Berg, Robin; Murray, Peter; Koppenol, Wieneke P; Zeder, Christophe; Zimmermann, Michael B; Moretti, Diego

    2016-08-01

    Fe fortification of centrally manufactured and frequently consumed condiments such as bouillon cubes could help prevent Fe deficiency in developing countries. However, Fe compounds that do not cause sensory changes in the fortified product, such as ferric pyrophosphate (FePP), exhibit low absorption in humans. Tetra sodium pyrophosphate (NaPP) can form soluble complexes with Fe, which could increase Fe bioavailability. Therefore, the aim of this study was to investigate Fe bioavailability from bouillon cubes fortified with either FePP only, FePP+NaPP, ferrous sulphate (FeSO4) only, or FeSO4+NaPP. We first conducted in vitro studies using a protocol of simulated digestion to assess the dialysable and ionic Fe, and the cellular ferritin response in a Caco-2 cell model. Second, Fe absorption from bouillon prepared from intrinsically labelled cubes (2·5 mg stable Fe isotopes/cube) was assessed in twenty-four Fe-deficient women, by measuring Fe incorporation into erythrocytes 2 weeks after consumption. Fe bioavailability in humans increased by 46 % (P<0·005) when comparing bouillons fortified with FePP only (4·4 %) and bouillons fortified with FePP+NaPP (6·4 %). Fe absorption from bouillons fortified with FeSO4 only and with FeSO4+NaPP was 33·8 and 27·8 %, respectively (NS). The outcome from the human study is in agreement with the dialysable Fe from the in vitro experiments. Our findings suggest that the addition of NaPP could be a promising strategy to increase Fe absorption from FePP-fortified bouillon cubes, and if confirmed by further research, for other fortified foods with complex food matrices as well.

  14. Investigation of the interaction of hydroxyapatite with technetium in association with stannous pyrophosphate

    International Nuclear Information System (INIS)

    Billinghurst, M.W.; Jette, D.; Somers, E.

    1981-01-01

    The individual components of technetium-99m stannous pyrophosphate were studied with respect to their interaction with hydroxyapatite. It is demonstrated that the role of the pyrophosphate molecule is one of a solubilizing and transporting molecule to carry the technetium atom to the site of the hydroxyapatite where the chelate disassociates and both the pyrophosphate and the technetium individually bind to the hydroxyapatite. The stannous ion is shown to associate with the hydroxyapatite also and although also solubilized by the pyrophosphate appears to be less strongly associated with the pyrophosphate. (author)

  15. Quantitative evaluation of renal dynamic scan with 99mTc-MAG3 assessment of interoposterior myocardial infarction using ECG gated SPECT with 99mTc-MIBI

    International Nuclear Information System (INIS)

    Cho, Keiichi; Kumita, Shinichiro; Mizumura, Sunao

    1997-01-01

    Simultaneous assessment of regional myocardial perfusion and local contraction ability of interoposterior myocardial infarction was examined by ECG gated SPECT. In thirteen cases of acute interoposterior myocardial infarction, the above-mentioned data were obtained by 180deg data acquisition method using L-shaped 2 detecting element type gamma camera. Mean and standard deviation of %Uptake and wall thickening (WT) in inferior wall were as follows: Infarction case; 57±9.2%/23±11.3%, normal case; 71±8.2%/61±10.2%. The significant depression (p<0.01/p<0.001) of both data were found in the infarction case. The both data in posterior wall were as follows: Infarction case; 55±10.7%/16±8.9%, normal case; 64±9.7%/41±15.0%. The significant depression (p<0.05/p<0.001) were also found in the infarction case. In both inferior wall and posterior wall, the AUC of ROC curve of WT was greater than that of %Uptake, and diagnostic ability of this method was favorable. The best sensitivity/specificity rate and the threshold were as follows: %Uptake of inferior wall 77/65, -0.5SD, WT of inferior wall 100/100, -2SD, %Uptake of posterior wall 62/82, -1SD, WT of posterior wall 85/88, -4SD. Accordingly, in diagnosis of interoposterior myocardial infarction, assessment of focus cardiac function, for example WT, is necessary as well as %Uptake. (K.H.)

  16. Dissolution behaviour of ferric pyrophosphate and its mixtures with soluble pyrophosphates: Potential strategy for increasing iron bioavailability.

    Science.gov (United States)

    Tian, Tian; Blanco, Elena; Smoukov, Stoyan K; Velev, Orlin D; Velikov, Krassimir P

    2016-10-01

    Ferric pyrophosphate (FePP) is a widely used iron source in food fortification and in nutritional supplements, due to its white colour, that is very uncommon for insoluble Fe salts. Although its dissolution is an important determinant of Fe adsorption in human body, the solubility characteristics of FePP are complex and not well understood. This report is a study on the solubility of FePP as a function of pH and excess of pyrophosphate ions. FePP powder is sparingly soluble in the pH range of 3-6 but slightly soluble at pH8. In the presence of pyrophosphate ions the solubility of FePP strongly increases at pH 5-8.5 due to formation a soluble complex between Fe(III) and pyrophosphate ions, which leads to an 8-10-fold increase in the total ionic iron concentration. This finding is beneficial for enhancing iron bioavailability, which important for the design of fortified food, beverages, and nutraceutical products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  17. Application of transmission scan-based attenuation compensation to scatter-corrected thallium-201 myocardial single-photon emission tomographic images

    International Nuclear Information System (INIS)

    Hashimoto, Jun; Kubo, Atsushi; Ogawa, Koichi; Ichihara, Takashi; Motomura, Nobutoku; Takayama, Takuzo; Iwanaga, Shiro; Mitamura, Hideo; Ogawa, Satoshi

    1998-01-01

    A practical method for scatter and attenuation compensation was employed in thallium-201 myocardial single-photon emission tomography (SPET or ECT) with the triple-energy-window (TEW) technique and an iterative attenuation correction method by using a measured attenuation map. The map was reconstructed from technetium-99m transmission CT (TCT) data. A dual-headed SPET gamma camera system equipped with parallel-hole collimators was used for ECT/TCT data acquisition and a new type of external source named ''sheet line source'' was designed for TCT data acquisition. This sheet line source was composed of a narrow long fluoroplastic tube embedded in a rectangular acrylic board. After injection of 99m Tc solution into the tube by an automatic injector, the board was attached in front of the collimator surface of one of the two detectors. After acquiring emission and transmission data separately or simultaneously, we eliminated scattered photons in the transmission and emission data with the TEW method, and reconstructed both images. Then, the effect of attenuation in the scatter-corrected ECT images was compensated with Chang's iterative method by using measured attenuation maps. Our method was validated by several phantom studies and clinical cardiac studies. The method offered improved homogeneity in distribution of myocardial activity and accurate measurements of myocardial tracer uptake. We conclude that the above correction method is feasible because a new type of 99m Tc external source may not produce truncation in TCT images and is cost-effective and easy to prepare in clinical situations. (orig.)

  18. Myocardial Bridging

    Directory of Open Access Journals (Sweden)

    Shi-Min Yuan

    2016-02-01

    Full Text Available Abstract Myocardial bridging is rare. Myocardial bridges are most commonly localized in the middle segment of the left anterior descending coronary artery. The anatomic features of the bridges vary significantly. Alterations of the endothelial morphology and the vasoactive agents impact on the progression of atherosclerosis of myocardial bridging. Patients may present with chest pain, myocardial infarction, arrhythmia and even sudden death. Patients who respond poorly to the medical treatment with β-blockers warrant a surgical intervention. Myotomy is a preferred surgical procedure for the symptomatic patients. Coronary stent deployment has been in limited use due to the unsatisfactory long-term results.

  19. Oxidative dehydrogenation of isobutane over a titanium pyrophosphate catalyst

    Directory of Open Access Journals (Sweden)

    IOAN-CEZAR MARCU

    2005-06-01

    Full Text Available The catalytic properties of titanium pyrophosphate in the oxidative dehydrogenation of isobutane to isobutylene were investigated in the 400 – 550 ºC temperature range. Asignificant change of the product distribution and of the apparent activation energy of the reactionwas observed at about 490 ºC. This phenomenon, already observed in the oxidative dehydrogenation of n-butane, has been interpreted by the existence of two reaction mechanisms depending upon the reaction temperature. Comparison with the n-butane reaction allowed different activation pathways for the activation of alkanes to be proposed. The catalytic properties of TiP2O7 in the oxidative dehydrogenation of isobutane was also compared to those obtained previously with several other pyrophosphates and TiP2O7 was found to be less active and selective for this reaction.

  20. Studying thermal dehydration of double nickel alkali metal pyrophosphates

    International Nuclear Information System (INIS)

    Bykanova, T.A.; Lavrov, A.V.; AN SSSR, Moscow. Inst. Obshchej i Neorganicheskoj Khimii)

    1978-01-01

    The methods of thermogravimetry, paper chromatography, infrared spectroscopy and X-ray phase analysis were used in studying the process of thermal dehydration of pyrophosphates of the M 2 Ni 3 (P 2 O 7 ) 2 xnH 2 O type (where n=6, 10; M=Na, K, Rb, Cs, NH 4 ). The dehydration of Cs 2 Ni 3 (P 2 O 7 ) 2 x10H 2 O proceeds in a single stage (endothermal effect at 210 deg C). The exothermal effects at 730 and 690 deg C correspond to the crystallization of the amorphous dehydration products. It has been established that binary pyrophosphates of nickel with alkali metals decompose when heated into Ni 3 (PO 4 ) 2 +MPO 4

  1. Quality control for a group of pyrophosphate-Sn kits

    International Nuclear Information System (INIS)

    Isaac, M.; Gamboa, R.; Hernandez, I.; Leyva, R.; Turino, D.

    1994-01-01

    The quality control for a group of Pyrophosphate-Sn kits for labeling with 99 m Tc is carry out at the Isotope Center. A general discussion takes place about the instrumental techniques for the determination of the kit constituent such as ligands, Sn(II), water, etc, as well as the control table for the evaluation of the warranty time. (author). 5 refs, 4 figs

  2. β-pyrophosphate: A potential biomaterial for dental applications

    OpenAIRE

    Anastasiou, AD; Strafford, S; Posada-Estefan, O; Thomson, CL; Hussaein, SA; Edwards, TJ; Malinowski, M; Hondow, N; Metzger, NK; Brown, CTA; Routledge, MN; Brown, AP; Duggal, MS; Jha, A

    2017-01-01

    Tooth hypersensitivity is a growing problem affecting both the young and ageing population worldwide. Since an effective and permanent solution is not yet available, we propose a new methodology for the restoration of dental enamel using femtosecond lasers and novel calcium phosphate biomaterials. During this procedure the irradiated mineral transforms into a densified layer of acid resistant iron doped β-pyrophosphate, bonded with the surface of eroded enamel. Our aim therefore is to evaluat...

  3. Controllable Fabrication of Amorphous Co-Ni Pyrophosphates for Tuning Electrochemical Performance in Supercapacitors.

    Science.gov (United States)

    Chen, Chen; Zhang, Ning; He, Yulu; Liang, Bo; Ma, Renzhi; Liu, Xiaohe

    2016-09-07

    Incorporation of two transition metals offers an effective method to enhance the electrochemical performance in supercapacitors for transition metal compound based electrodes. However, such a configuration is seldom concerned in pyrophosphates. Here, amorphous phase Co-Ni pyrophosphates are fabricated as electrodes in supercapacitors. Through controllably adjusting the ratios of Co and Ni as well as the calcination temperature, the electrochemical performance can be tuned. An optimized amorphous Ni-Co pyrophosphate exhibits much higher specific capacitance than monometallic Ni and Co pyrophosphates and shows excellent cycling ability. When employing Ni-Co pyrophosphates as positive electrode and activated carbon as a negative electrode, the fabricated asymmetric supercapacitor cell exhibits favorable capacitance and cycling ability. This study provides facile methods to improve the transition metal pyrophosphate electrodes for efficient electrodes in electrochemical energy storage devices.

  4. Expression, crystallization and preliminary crystallographic study of octaprenyl pyrophosphate synthase from Helicobacter pylori

    International Nuclear Information System (INIS)

    Zhang, Jinyong; Zhang, Xiaoli; Mao, Xuhu; Zou, Quanming; Li, Defeng

    2011-01-01

    Octaprenyl pyrophosphate synthase from H. pylori has been expressed, purified and crystallized, and a diffraction data set was collected to 2.00 Å resolution. Octaprenyl pyrophosphate synthase (OPPs) is involved in the synthesis of the side chains of ubiquinone and menaquinone and catalyzes consecutive condensation reactions of farnesyl pyrophosphate with isopentenyl pyrophosphate to generate polyprenyl pyrophosphate and pyrophosphate. In order to investigate the roles played by OPPs in the metabolism of ubiquinone and menaquinone and the enzymatic mechanisms of these enzymes, analysis of the structure–function relationship of OPPs from Helicobacter pylori was initiated. The gene for OPPs was cloned, the protein was expressed, purified and crystallized and a diffraction data set was collected to 2.00 Å resolution. The crystals belonged to space group P4 1 2 1 2 or P4 3 2 1 2, with unit-cell parameters a = b = 109.33, c = 103.41 Å

  5. 99m Technetium pyrophosphate myocardium scintigraphy. First results

    International Nuclear Information System (INIS)

    Toussaint, Paul.

    1976-01-01

    99m technetium pyrophosphate myocardium scintigraphy is a very recent examination technique. This work gives the results obtained on 61 patients. As a vector of the isotope, pyrophosphate has the advantage over polyphosphate of a fast bone uptake there it should be stressed that a 90 minute pause is necessary between the intraveinous injection of the isotope and the photographic recording so that the reading is not troubled by the labelled intracardiac blood pool image, an image quality criterion being the estimation of a good costal fixation which in fact appears sooner or later according to the subject. The role of pyrophosphate, chelator of calcium in fixation of the isotope on the myocardium, could be explained by the fast appearance of 'dense bodies', made up of calcium hydroxyapathice crystals, in the mitochondria of myocardium cells having undergone an irreversible necrotic process. The choice of 99 m technetium is based on its ease of use: 6 hour half-life, high-energy pure gamma emission at 140 keV. The fixed image studied under two incidences, front and left anterior oblique, is obtained from mobile images given by the scintillation camera used in connection with a data processing system. Several facts are underlined, explaining the disadvantages, advantages and indications of the method [fr

  6. A pyrophosphate-responsive gadolinium(III) MRI contrast agent.

    Science.gov (United States)

    Surman, Andrew J; Bonnet, Célia S; Lowe, Mark P; Kenny, Gavin D; Bell, Jimmy D; Tóth, Eva; Vilar, Ramon

    2011-01-03

    This study shows that the relaxivity and optical properties of functionalised lanthanide-DTPA-bis-amide complexes (lanthanide=Gd(3+) and Eu(3+) , DTPA=diethylene triamine pentaacetic acid) can be successfully modulated by addition of specific anions, without direct Ln(3+) /anion coordination. Zinc(II)-dipicolylamine moieties, which are known to bind strongly to phosphates, were introduced in the amide "arms" of these ligands, and the interaction of the resulting Gd-Zn(2) complexes with a range of anions was screened by using indicator displacement assays (IDAs). Considerable selectivity for polyphosphorylated species (such as pyrophosphate and adenosine-5'-triphosphate (ATP)) over a range of other anions (including monophosphorylated anions) was apparent. In addition, we show that pyrophosphate modulates the relaxivity of the gadolinium(III) complex, this modulation being sufficiently large to be observed in imaging experiments. To establish the binding mode of the pyrophosphate and gain insight into the origin of the relaxometric modulation, a series of studies including UV/Vis and emission spectroscopy, luminescence lifetime measurements in H(2) O and D(2) O, (17) O and (31) P NMR spectroscopy and nuclear magnetic resonance dispersion (NMRD) studies were carried out. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    OpenAIRE

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    Inositol pyrophosphates are messenger molecules incorporating the energetic pyrophosphate bond. Although they have been implicated in diverse biologic processes, their physiologic functions remain enigmatic. We show that the catalytic activity of inositol hexakisphosphate kinase 2 (IP6K2), one of the principal enzymes generating the inositol pyrophosphate IP7 (5-diphosphoinositolpentakisphosphate), mediates cancer cell migration and tumor metastasis both in cell culture and intact mice. In th...

  8. Ventricular and myocardial scintiscanning: Methodical fundamentals

    International Nuclear Information System (INIS)

    Standke, R.; Hoer, G.; Maul, F.D.

    1984-01-01

    Nuclear cardiology is concerned with non invasive procedures to quantitate global and regional left ventricular function (Radionuclide ventriculography), also the imaging of vitally perfused myocardium (Myocardial scintigraphy) is achieved. A gammacamera and a minicomputer are necessary. Radionuclide ventriculography enables the analysis of global and regional time dependent left ventricular volume curves and hence the evaluation of contraction and contractility of the heart muscle. The basis is a sequence of scans covering an average heartcycle. This sequence may be produced either by first pass or equilibrium technique. Myocardial scintigraphy at rest images vital myocardium, scans immediately after exercise represent the interference of myocardial perfusion and muscle mass. The regional difference (Redistribution) between normalized exercise- and rest scans provide quantitative parameters to detect impairment of exercise-induced myocardial perfusion anomalies. The procedures of sectorial analysis of left ventricular function and myocardial perfusion are presented. (orig.) [de

  9. The Role of Routine Whole Volume SPECT Reconstruction in Comparison to Cine Raw Data in the Detection of Extracardiac Uptake on Myocardial Perfusion Scans

    International Nuclear Information System (INIS)

    Maharaj, M.; Korowlay, N.A.

    2011-01-01

    The objective of this study was to determine the role of routine whole volume reconstructed single-photon emission tomography (rSPECT) compared to cine raw data to detect extracardiac uptake of Sestamibi (MIBI). In a retrospective study, the myocardial perfusion studies of 426 patients were inspected separately for extracardiac uptake on cine raw data and rSPECT. The acquisition parameters for all the images were done according to departmental protocol. The whole volume SPECT data was selected and processed by HOSEM iterative reconstruction using the HERMES computer software system. The images were assessed by two observers, a student in training and a senior consultant nuclear medicine physician. The overall mean age and standard deviation of the 426 patients at the time of the study was 60 ± 12 years. Statistical analysis was performed using the Kappa and McNemars tests. The clinical significance of the extracardiac uptake was evaluated using hospital folders and /or laboratory results after viewing images. rSPECT detected 25 patients (5.9%) and cine raw data identified 18 patients (4.2%) with extracardiac uptake. All the areas of extracardiac uptake noted on cine raw data were seen on the rSPECT images. Only 21 of the 25 patients had complete 5-year clinical follow-up. The value of the clinical significance of the extracardiac uptake was limited due to the study being retrospective. The proportion of positives identified by rSPECT was significantly larger than those identified by cine raw data (P = 0.0082). Although our study demonstrates that rSPECT is more sensitive than cine raw data in detecting extracardiac uptake, it also shows that there is no benefit in routine whole volume rSPECT in daily clinical practice

  10. Determination of stability constants of pyrophosphate complexes. 2. Influence of divalent cations: the magnesium

    International Nuclear Information System (INIS)

    Courriere, P.; Guillemart, A.; Besnard, J.-C.

    1978-01-01

    The stability constants of the complexes of pyrophosphate with magnesium have been determined directly from the titration curves of sodium pyrophosphate in presence of Mg 2+ with hydrochloric acid by a least-square iterative method at the temperature of 25 0 C and at a ionic strength adjusted to unity [fr

  11. The pyrophosphate heart scintigram in children with progressive muscular dystrophy

    International Nuclear Information System (INIS)

    Duska, F.; Nesvadba, Z.; Zdansky, P.; Novak, J.; Kubicek, J.; Kafka, P.; Vizda, J.; Mazurova, Y.; Karlova Univ., Hradec Kralove; Karlova Univ., Hradec Kralove

    1984-01-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index. (orig.) [de

  12. Pyrophosphate heart scintigram in children with progressive muscular dystrophy

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Nesvadba, Z; Zdansky, P; Novak, J; Kubicek, J; Kafka, P; Vizda, J; Mazurova, Y

    1984-08-01

    A pyrophosphate heart scintigram was obtained in 16 boys with progressive muscular dystrophy Duchenne. All of them showed pathological ECG findings and high plasma levels of CK, AST, ALT and LD. In 4 patients the scintigram was distinctly positive and in further 3 it reached borderline values. The remaining 9 boys had normal scintigraphic findings. Those with a positive heart scintigram had very high plasma levels of the enzymes under study which was suggestive of current progression of the disease. There was, however, no relation between heart scintigraphy and the affliction of the skeletal muscles expressed by means of an index.

  13. High-risk angina patient: identification by clinical features, hospital course, electrocardiography, and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p < 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p < 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup, with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  14. High-risk angina patient. Identification by clinical features, hospital course, electrocardiography and technetium-99m stannous pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Olson, H.G.; Lyons, K.P.; Aronow, W.S.; Stinson, P.J.; Kuperus, J.; Waters, H.J.

    1981-01-01

    We evaluated 193 consecutive unstable angina patients by clinical features, hospital course and electrocardiography. All patients were managed medically. Of the 193 patients, 150 (78%) had a technetium-99m pyrophosphate (Tc-PYP) myocardial scintigram after hospitalization. Of these, 49 (33%) had positive scintigrams. At a follow-up of 24.9 +/- 10.8 months after hospitalization, 16 of 49 patients (33%) with positive scintigrams died from cardiac causes, compared with six of 101 patients (6%) with negative scintigrams (p less than 0.001). Of 49 patients with positive scintigrams, 11 (22%) had had nonfatal myocardial infarction at follow-up, compared with seven of 101 patients (7%) with negative scintigrams (p less than 0.01). Age, duration of clinical coronary artery disease, continuing angina during hospitalization, ischemic ECG, cardiomegaly and a history of heart failure also correlated with cardiac death at follow-up. Ischemic ECG and a history of angina with a crescendo pattern also correlated with nonfatal infarction at follow-up. Patients with continuing angina, an ischemic ECG and a positive scintigram constituted a high-risk unstable angina subgroup with a survival rate of 58% at 6 months, 47% at 12 months and 42% at 24 and 36 months. We conclude that the assessment of clinical features, hospital course, ECG and Tc-PYP scintigraphy may be useful in identifying high-risk unstable angina patients

  15. About 250 cases of skeletal scintiscanning using sup(99m)Tc-labelled stannous pyrophosphate. Analytical and critical study

    International Nuclear Information System (INIS)

    Suss, Leopold.

    1975-01-01

    The physical and biological characteristics of 85 Sr, 87 Sr, 18 F and sup(99m)Tc, four radionuclides suitable for skeletal imaging are reviewed. Their mechanism of localization, advantages and disadvantages are described. The physical characteristics and relative tissue concentration of sup(99m)Tc compare favorably to those of the other bone-seeking radionuclides. 250 cases of various skeletal diseases are presented, using sup(99m)Tc-pyrophosphate as a skeletal imaging agent. This radiopharmaceutical proves to be useful particularly in the detection of bone metastases. Bone scans, however, are not 100% positive with metastatic diseases and false negative do occasionally occur. The scan is also helpful in demonstrating the extent of metastatic bone disease [fr

  16. Complexes of technetium with pyrophosphate, etidronate, and medronate

    International Nuclear Information System (INIS)

    Russell, C.D.; Cash, A.G.

    1979-01-01

    The reduction of [ 99 Tc]pertechnetate was studied as a function of pH in complexing media of pyrophosphate, methylene diphosphonate (MDP), and ethane-1, hydroxy-1, and 1-diphosphonate (HEDP). Test (sampled d-c) and normal-pulse polarography were used to study the reduction of pertechnetate, and normal-pulse polarography (sweeping in the anodic direction) to study the reoxidation of the products. Below pH 6 TcO 4 - was reduced to Tc(III), which could be reoxidized to Tc(IV). Above pH 10, TcO 4 - was reduced in two steps to Tc(V) and Tc(IV), each of which could be reoxidized to TcO 4 - . Between pH 6 and 10 the results differed according to the ligand present. In pyrophosphate and MDP, TcO 4 - was reduced in two steps to Tc(IV) and Tc(III); Tc(III) could be reoxidized in two steps to Tc(IV) and TcO 4 - . In HEDP, on the other hand, TcO 4 - was reduced in two steps to Tc(V) and Tc(III), and could be reoxidized to Tc(IV) and TcO 4 - . Additional waves were observed; they apparently led to unstable products

  17. The cardiomyopathy in Friedreich's ataxia: isotopic ventriculography and myocardial imaging with thallium-201

    International Nuclear Information System (INIS)

    Therriault, L.; Lamoureux, G.; Cote, M.; Plourde, G.; Lemieux, B.

    1984-01-01

    Myocardial scanning after the intravenous administration of Thallium 201 was used to evaluate regional myocardial perfusion in 14 patients with Friedreich's ataxia. Isotopic ventriculography was also used to assess left ventricular contractility. Myocardial images in patients with Friedreich's ataxia were found to be precociously abnormal irrespective of the degree of neurological impairment or of the severity of myocardial hypertrophy

  18. Contribution of technetium pyrophosphate bone scintigraphy in the evaluation of prostate cancer extension based on 100 cases

    International Nuclear Information System (INIS)

    Oliveux, Alain.

    1976-01-01

    The aim of this work was to compare the results of technetium 99m pyrophosphate bone scintigraphy with those of the standard radiographic exploration of the skeleton in order to find out whether scintigraphic data allow an earlier and more accurate diagnosis of the presence of bone metastases. The dose administered is about 10MCi per patient; the recording is made 4 hours after intraveinous injection of the tracer. The documents are obtained in two stages: - first of all a whole-body scintigraph is carried out by means of an 'omniview' system adapted to the Picker dynacamera. This instrument gives an image of the entire body by translation of the patient's bed before the detection head of the camera; - immediately after the whole-body scan a series of static views is taken, especially on abnormal or doubtful areas. These documents have a better resolution than the reduced whole-body image and supply complementary data all the more valuable as they are directed towards the zones of interest. Analysis of our observations underlines the advantages of technetium 99m pyrophosphate bone scintigraphy in the evaluation of prostate neoplasm extension. This particularly sensitive method of investigation enables bone metastases to be detected earlier and more precisely in a patient presenting a neoplasm [fr

  19. Investigating the pharmacodynamic and magnetic properties of pyrophosphate-bridged coordination complexes

    Science.gov (United States)

    Ikotun, Oluwatayo (Tayo) F.

    The multidentate nature of pyrophosphate makes it an attractive ligand for complexation of metal cations. The participation of pyrophosphate in a variety of biological pathways and its metal catalyzed hydrolysis has driven our investigation into its coordination chemistry. We have successfully synthesized a library of binuclear pyrophosphate bridge coordination complexes. The problem of pyrophosphate hydrolysis to phosphate in the presence of divalent metal ions was overcome by incorporating capping ligands such as 1,10-phenanthroline and 2,2'-bipyridine prior to the addition of the pyrophosphate. The magnetic properties of these complexes was investigated and magneto-structural analysis was conducted. The biological abundance of pyrophosphate and the success of metal based drugs such as cisplatin, prompted our investigation of the cytotoxic properties of M(II) pyrophosphate dimeric complexes (where M(II) is CoII, CuII, and NiII) in adriamycin resistant human ovarian cancer cells. Thess compounds were found to exhibit toxicity in the nanomolar to picomolar range. We conducted in vitro stability studies and the mechanism of cytoxicity was elucidated by performing DNA mobility and binding assays, enzyme inhibition assays, and in vitro oxidative stress studies.

  20. Comparison of several potential myocardial imaging agents

    International Nuclear Information System (INIS)

    Watson, E.E.; Stabin, M.G.; Goodman, M.M.; Knapp, F.F. Jr.; Srivastava, P.C.

    1985-01-01

    Although myocardial imaging is currently dominated by Tl-201, several alternative agents with improved physiologic or radionuclidic properties have been proposed. Based on human and animal studies in the literature, the metabolism of several of these compounds was studied for the purpose of generating radiation dose estimates. Dose estimates are listed for several I-123 labeled free fatty acids, an I-123 labeled phosphonium compound, Rb-82, Cu-64, F-18 FDG (all compounds which are taken up by the normal myocardium), and for Tc-99m pyrophosphate (PYP) (which localizes in myocardial infarcts). Dose estimates could not be generated for C-11 palmitate, but this compound was included in a comparison of myocardial retention times. For the I-123 labeled compounds, I-124 was included as a contaminant in generating the dose estimates. Radiation doses were lowest for Rb-82 (gonads 0.3 to 0.5 μGy/MBq, heart wall 15 μGy/MBq). Doses for the I-123 labeled fatty acids were similar to one another, with IPPA being the lowest (gonads 20 μGy/MBq, heart wall 15 μGy/MBq). Doses for Tc-99m PYP were also low (gonads 4 to 7 μGy/MBq, heart wall 4 μGy/MBq, skeleton 15 μGy/MBq). The desirability of these compounds is discussed briefly, considering half life, imaging mode and energy, and dosimetry, including a comparison of the effective whole body dose equivalents. 34 refs., 11 tabs

  1. Scintigraphic evaluation of suspected acute myocardial infarction

    International Nuclear Information System (INIS)

    Kan, M.K.; Hopkins, G.B.; Carroll, C.F.X.

    1977-01-01

    Ninety-one patients with chest pain suggestive of acute myocardial infarction were studied by static technetium /sup 99m/Tc stannous pyrophosphate scintigraphy and dynamic sodium pertechnetate /sup 99m/Tc cardioangiography. Twenty-three of 26 patients (88%) with acute transmural infarcts and 12 of 17 patients (71%) with nontransmural infarcts had abnormal static studies. In 45 patients with negative scintigrams, ECG or serum enzyme changes consistent with acute infarction failed to develop. Three false-positive static studies (6%) were recorded. Twenty of 43 (47%) patients with acute infarction had hemodynamic or structural abnormalities identified by cardioangiography. The dynamic study also proved helpful in localizing the site of infarction and in ruling out certain causes of false-positive static scintigrams

  2. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C. [Universidade de Sao Paulo (FM/USP), SP (Brazil). Fac. de Medicina. Instituto do Coracao. Servico de Medicina Nuclear e Imagem Molecular

    2008-07-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate-{sup 99m}Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate-{sup 99m}Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders

  3. Cardiac amyloidosis detection with pyrophosphate-99mTc scintigraphy

    International Nuclear Information System (INIS)

    Souza, D.S.F.; Ichiki, W.A.; Coura Filho, G.B.; Izaki, M.; Giorgi, M.C.P.; Soares Junior, J; Meneghetti, J.C.

    2008-01-01

    Full text: Introduction: Amyloidosis is a rare disease, characterized by extracellular deposition of insoluble amyloid fibrils in organs and tissues. It may affect virtually any system, preferably heart, kidneys and liver. The cardiac involvement produces a spectrum of clinical features, usually with progressive dysfunction. Early diagnosis is important for institution of appropriate therapy. Case report: Male patient, 75 years old, with diagnosed congestive heart failure functional class III and Mobitz II second-degree atrial-ventricular block, was hospitalized for implantation of definitive cardiac pacemaker. Patient mentioned history of worsening effort dyspnoea over a one-month period, progressing to minimum effort, orthopnea, paroxysmal nocturnal dyspnoea and paroxysms of dry cough, and swelling of lower limbs. Echocardiography showed diffuse hypertrophy of left ventricle (LV), with systolic dysfunction due to diffuse hypokinesia and hyperrefringent aspect in the septum. It was questioned a cardiac infiltrating process. Cardiac amyloidosis was considered as a diagnostic hypothesis. The patient underwent a pyrophosphate- 99m Tc scintigraphy, which showed abnormal tracer uptake in the heart projection, with diffuse pattern on the left ventricle walls, compatible with the clinical suspicion cardiac amyloidosis, which was later confirmed by endomyocardial biopsy. Discussion: In this case report, the patient had clinical and other auxiliary examinations, such as electrocardiography and Doppler echocardiography, compatible with cardiac amyloidosis, which led to implementation with pyrophosphate- 99m Tc scintigraphy and later endomyocardial biopsy. Cardiac amyloidosis occurs in about half the cases of primary amyloidosis (AL) and is rare in secondary amyloidosis (AA). Its clinical presentation is polymorphic and it can be classified into four distinctive types: restrictive cardiomyopathy, systolic dysfunction, postural hypotension and conduction disorders. Cardiac

  4. Reversible myocardial ischaemia or irreversible myocardial fibrosis

    International Nuclear Information System (INIS)

    Mathey, D.; Hanrath, P.; Kupper, W.; Bleifeld, W.; Montz, R.; Knop, J.; Stritzke, P.; Kroeger, E.; Bleese, N.

    1978-01-01

    The results of biphasis 201 thallium ( 201 Tl) scanning were compared with those of coronary arteriography, left ventricular angiography and stress ECG in 56 patients with coronary artery disease and six with no evidence of heart disease. There were 104 201 Tl defects, 50 of them reversible. The defects were always located in the area supplied by a critically stenotic coronary artery. Correlation of regional wall motion with 201 Tl activity demonstrated that in all forms of abnormal wall motion there was either ischaemia or fibrosis. The resting LV angiogram thus does not make it possible to distinguish between myocardial ischaemia and fibrosis. Taking the LV angiogram as a standard, the rate of false-positive 201 Tl scintigrams was 5%, that of false-negative ones 23%. The biphasic 201 Tl scintigram was more sensitive than the stress ECG in detecting myocardial ischaemia. It furthermore made it possible to localize the ischaemic (or fibrotic) region within the LV and to estimate its size. (orig.) [de

  5. SPECT Myocardial Blood Flow Quantitation Concludes Equivocal Myocardial Perfusion SPECT Studies to Increase Diagnostic Benefits.

    Science.gov (United States)

    Chen, Lung-Ching; Lin, Chih-Yuan; Chen, Ing-Jou; Ku, Chi-Tai; Chen, Yen-Kung; Hsu, Bailing

    2016-01-01

    Recently, myocardial blood flow quantitation with dynamic SPECT/CT has been reported to enhance the detection of coronary artery disease in human. This advance has created important clinical applications to coronary artery disease diagnosis and management for areas where myocardial perfusion PET tracers are not available. We present 2 clinical cases that undergone a combined test of 1-day rest/dipyridamole-stress dynamic SPECT and ECG-gated myocardial perfusion SPECT scans using an integrated imaging protocol and demonstrate that flow parameters are capable to conclude equivocal myocardial perfusion SPECT studies, therefore increasing diagnostic benefits to add value in making clinical decisions.

  6. Scintigraphic diagnosis of experimentally induced pericarditis in dogs using 99sup(m)Tc-labelled pyrophosphate

    International Nuclear Information System (INIS)

    Duska, F.; Novak, J.; Vizda, J.; Kubizek, J.; Simon, J.; Veverkova, O.; Karlova Universita, Hradec Kralove

    1981-01-01

    In the present paper the possibilities of scintigraphic diagnosis of experimental pericarditis are discussed. Pericarditis was induced by either talc or formaldehyde intrapericardially. In all animals the administration of talc as well as formaldehyde produced inflammatory changes which were more serious after formaldehyde. The scan of the talc pericarditis was carried out on the 7th day after operation and of the formaldehyde pericarditis on the 3rd, 7th and 14th day. No positive scintigraphic finding was made in any of the experimental animals, apart from a massive incorporation in the operation scars. The counting of radioactive impulses after the exstirpation of the tissue samples confirmed the scintigraphic findings. Statistical evaluation did not reveal any essential difference between the accumulation of the radiopharmaceutical into the pericarditis as well as into the pericardial bag in comparison with the control animals. Although our model does not exactly reflect the situation of patients suffering from pericarditis it may be assumed that pyrophosphate scintigraphy is not suitable for the diagnosis of acute pericarditis in clinical practice. (orig.) [de

  7. Experience based on 60 observations of scintigraphic bone exploration using pyrophosphates

    International Nuclear Information System (INIS)

    Mienville, J.-C.

    1975-01-01

    5 to 15 millicuries of technetium 99m-labelled pyrophosphates are injected intraveinously. 3 to 5 hours later, when the blood activity has dropped, the bone uptake is sufficient to give a good scintigraphic image of the skeleton. The skeleton may be explored one segment at a time, using a scanning scintigraph or a scintillation camera, or the whole skeleton front and back may be examined much more quickly with a 'whole-body' device. A study of 60 observations shows the large number of hyperfixations revealed by isotopic explorations in rheumatological diseases. A hyperfixation was observed in almost all bone localities of osteophilic cancers, osteonecrosis, Paget's disease, infections osteo-arthritis and algoneurodystrophy. On the other hand the isotopic test was found to be negative or inefficient in arthroses, osteoporosis and local bone manifestations of Kahler's or Hodgkin's disease. Finally inflammatory arthritis was detectable by scintigraphy in about half the cases studied. In reality a hyperfixation reflects a local rise in the metabolic activity of the bone at the moment of the examination. As a result the scintigraphic images lack specificity. This factor must therefore be accounted for in the patient's records and isotopic results compared with those of clinical and para-clinical examinations [fr

  8. Pyrophosphate as a central energy carrier in the hydrogen-producing extremely thermophilic Caldicellulosiruptor saccharolyticus

    NARCIS (Netherlands)

    Bielen, A.A.M.; Willquist, K.; Engman, J.; Oost, van der J.; Niel, van E.W.J.; Kengen, S.W.M.

    2010-01-01

    The role of inorganic pyrophosphate (PPi) as an energy carrier in the central metabolism of the extremely thermophilic bacterium Caldicellulosiruptor saccharolyticus was investigated. In agreement with its annotated genome sequence, cell extracts were shown to exhibit PPi-dependent

  9. Heterovalent Zr4+ - Cu2+ substitution in zirkonium pyrophosphate: From theoretical models to synthesis and utilization

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Šulcová, P.; Bosacka, M.; Filipek, E.; Vlček, Milan

    2015-01-01

    Roč. 35, č. 15 (2015), s. 4293-4305 ISSN 0955-2219 Institutional support: RVO:61389013 Keywords : zirconium pyrophosphate * cooper phosphates * thermal stability Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 2.933, year: 2015

  10. Definition and Reliability Assessment of Elementary Ultrasonographic Findings in Calcium Pyrophosphate Deposition Disease

    DEFF Research Database (Denmark)

    Filippou, Georgios; Scirè, Carlo A; Damjanov, Nemanja

    2017-01-01

    OBJECTIVE: To define the ultrasonographic characteristics of calcium pyrophosphate crystal (CPP) deposits in joints and periarticular tissues and to evaluate the intra- and interobserver reliability of expert ultrasonographers in the assessment of CPP deposition disease (CPPD) according to the ne...

  11. Factors affecting the stability and biodistribution of {sup 99m} Tc labelled Sn-pyrophosphate freeze dried kits in normal mice.

    Energy Technology Data Exchange (ETDEWEB)

    Elkolaly, M T; Elwatery, A S; Elghany, E A [Radioisotope production and labelled compounds department, hot lab. center, Atomic Energy Authority, Cairo, (Egypt)

    1995-10-01

    The present study has shown that about 5% of Sn (II) in {sup 99m} Tc labelled Sn-pyrophosphate (Sn-PYP) freeze dried kit was oxidized during kit formulation. Also, {gamma}-irradiation doses of 25 and 50 KGy led to Sn (II) losses of about 9.8 and 27.7%, respectively. In-vitro stability and radiochemical purity were biologically confirmed in mice and a high quality scan was achieved on waiting for 3 hours after injection. 3 figs., 6 tabs.

  12. Pyrophosphate-Inhibition of Apatite Formation Studied by In Situ X-Ray Diffraction

    Directory of Open Access Journals (Sweden)

    Casper Jon Steenberg Ibsen

    2018-02-01

    Full Text Available The pathways to crystals are still under debate, especially for materials relevant to biomineralization, such as calcium phosphate apatite known from bone and teeth. Pyrophosphate is widely used in biology to control apatite formation since it is a potent inhibitor of apatite crystallization. The impacts of pyrophosphate on apatite formation and crystallization kinetics are, however, not fully understood. Therefore, we studied apatite crystallization in water by synchrotron in situ X-ray diffraction. Crystallization was conducted from calcium chloride (0.2 M and sodium phosphate (0.12 M at pH 12 where hydrogen phosphate is the dominant phosphate species and at 60 °C to allow the synchrotron measurements to be conducted in a timely fashion. Following the formation of an initial amorphous phase, needle shaped crystals formed that had an octacalcium phosphate-like composition, but were too small to display the full 3D periodic structure of octacalcium phosphate. At later growth stages the crystals became apatitic, as revealed by changes in the lattice constant and calcium content. Pyrophosphate strongly inhibited nucleation of apatite and increased the onset of crystallization from minute to hour time scales. Pyrophosphate also reduced the rate of growth. Furthermore, when the pyrophosphate concentration exceeded ~1% of the calcium concentration, the resultant crystals had reduced size anisotropy suggesting that pyrophosphate interacts in a site-specific manner with the formation of apatite crystals.

  13. Radiochemicals used to scan the heart

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Techniques for heart scanning using 201 Tl and /sup 99m/Tc pyrophosphate are discussed. Thallium-201, produced artificially in a cyclotron, concentrates in normal heart muscle but not in abnormal tissue. Technetium-99m is deposited in mitochondria of heart cells that are irreversibly damaged. The combined use of 201 Tl and /sup 99m/Tc makes it possible to identify regions of recent heart damage as well as older heart damage. Advantages of using 129 Cs for heart scanning are also discussed

  14. Diagnosis of acute myocardial infarction in patients undergoing open heart surgery: a comparison of serial myocardial imaging with cardiac enzymes, electrocardiography, and vectocardiography

    International Nuclear Information System (INIS)

    Lowenthal, I.S.; Parisi, A.F.; Tow, D.E.; Barsamian, E.M.; Sasahara, A.A.; McCaughan, D.; Clemson, H.C.

    1977-01-01

    In 44 consecutive patients undergoing elective open heart surgery (OHS), serial electrocardiograms (ECG), vectorcardiograms (VCG), serum CPK, cardiac isoenzymes (CPKMB), and myocardial images using Tc-99m pyrophosphate were obtained, before and after the operation, for the detection of acute myocardial infarction (AMI). Twenty-nine patients developed one or more positive tests postoperatively. Two patients had positive myocardial scintiscans; both had other evidence of infarction. Conversely, the appearance of CPKMB, or new ECG and VCG changes, occurred frequently without evidence of infarction, and were not associated with the development of a positive scintiscan. The results show that false-negative results are infrequent in patients imaged early after OHS, and that cardiac surgical procedures do not cause a high incidence of false-positive scintigrams. Consequently, radionuclide imaging for AMI offers an important adjunct for excluding acute infarction following open heart surgery

  15. Biosynthesis of monoterpenes: Stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to camphane and isocamphane monoterpenes

    International Nuclear Information System (INIS)

    Croteau, R.; Gershenzon, J.; Wheeler, C.J.; Satterwhite, D.M.

    1990-01-01

    The conversion of geranyl pyrophosphate to (+)-bornyl pyrophosphate and (+)-camphene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this bound intermediate. In the case of (-)-bornyl pyrophosphate and (-)-camphene, isomerization of the substrate to the (+)-(3S)-linalyl intermediate precedes cyclization. The geranyl and linalyl precursors were shown to be mutually competitive substrates (inhibitors) of the relevant cyclization enzymes isolated from Salvia officinalis (sage) and Tanacetum vulgare (tansy) by the mixed substrate analysis method, demonstrating that isomerization and cyclization take place at the same active site. Incubation of partially purified enzyme preparations with (3R)-[1Z-3H]linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate gave rise to double-labeled (+)-bornyl pyrophosphate and (+)-camphene, whereas incubation of enzyme preparations catalyzing the antipodal cyclizations with (3S)-[1Z-3H]-linalyl pyrophosphate plus [1-14C]geranyl pyrophosphate yielded double-labeled (-)-bornyl pyrophosphate and (-)-camphene. Each product was then transformed to the corresponding (+)- or (-)-camphor without change in the 3H:14C isotope ratio, and the location of the tritium label was deduced in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogen of the derived ketone. The finding that the 1Z-3H of the linalyl precursor was positioned at the endo-alpha-hydrogen of the corresponding camphor in all cases, coupled to the previously demonstrated retention of configuration at C1 of the geranyl substrate in these transformations, confirmed the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate and the cyclization of the latter via the anti,endo- conformer

  16. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    International Nuclear Information System (INIS)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of 201 TlCl myocardial scintigraphy in 35 patients and with those of 99m Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by 201 TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and 99m Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author)

  17. Phase analysis of gated blood pool scintigraphy in traumatic myocardial contusion

    Energy Technology Data Exchange (ETDEWEB)

    Nishimaki, Hiroshi; Kobayashi, Akiyoshi (Kitasato Univ., Sagamihara, Kanagawa (Japan). School of Medicine)

    1994-01-01

    It is not easy to make a diagnosis of myocardial contusion following blunt chest trauma, because most patients have many other concurrent injuries with diverse symptoms. The usefulness of phase analysis of gated blood pool scintigraphy (GBPS) for myocardial contusion following blunt chest trauma was evaluated. Thirty-eight patients who had been strongly suspected of having myocardial contusion from clinical symptoms and electrocardiograms underwent phase analysis of GBPS. The results of phase analysis were compared with those of two-dimensional echocardiography (2-D Echo) and CPK-MB fraction measurement in all patients, with those of [sup 201]TlCl myocardial scintigraphy in 35 patients and with those of [sup 99m]Tc-pyrophosphate scintigraphy in 10 patients. In 29 patients (76.3%), the results of phase analysis matched those of 2-D Echo. Two patients (5.3%) who were judged as positive by 2-D Echo and as negative by phase analysis had only rupture of the chordae. Only one of two other patients who were judged as negative by 2-D Echo and as positive by phase analysis was judged as positive by [sup 201]TlCl myocardial scintigraphy. The results of both 2-D Echo and phase analysis were not well correlated with those of CPK-MB fraction measurement and [sup 99m]Tc pyrophosphate scintigraphy. It is concluded that phase analysis of GBPS, as well as 2-D Echo, is useful for diagnosing myocardial contusion, and that phase analysis is most useful for diagnosing myocardial contusion in patients who cannot be examined by 2-D Echo because of the presence of pneumothorax and/or subcutaneous emphysema in the anterior chest wall. (author).

  18. sup(99m)Tc-pyrophosphate scintiscanning in diagnostic orthopaedics

    International Nuclear Information System (INIS)

    Rauscher, W.

    1983-01-01

    To assess the findings of nuclear skeletal examinations, the pathological course of the disease must be known as far as possible. Pyrophosphate is the substance that causes bone accumulation while the metastable technetium is a high-intensity gamma source. Positive scintiscan findings are obtained in all processes with clear changes in the bone structure, e.g. all stages of osteomyelitis, articular processes of different genesis, inflammations, or activations of the bone metabolism. In these cases also processes of the articular cartilage and, partly, the soft tissue will be imaged. Terminated processes and purely degenerative changes, which are rare in clinical practice, will remain quiescent. Examinations after trauma or after surgery show a typical healing process. Scintiscanning is particularly useful for examinations of skeletal parts that are difficult to image by radiological methods; on the other hand, it does not yield additional information on the fit of an endoprothesis. Primary skeletal tumours can be diagnosed with sufficient accuracy only by means of quantitative methods. Nuclear methods, with their accurate information on the dynamics of the bone metabolism, often yield valuable additional information for the purposes of diagnosis, therapy, and prognosis. (orig./MG) [de

  19. Technetium-99m stannous pyrophosphate imaging of experimental infective endocarditis

    International Nuclear Information System (INIS)

    Riba, A.L.; Downs, J.; Thakur, M.L.; Gottschalk, A.; Andriole, V.T.; Zaret, B.L.

    1978-01-01

    Technetium-99m stannous pyrophosphate (/sup 99m/Tc-PYP) cardiac scintigraphy was performed in 15 rabbits with experimental Streptococcus sanguis aortic-valve infective endocarditis. The animals were imaged five to seven days after the administration of bacteria, and in each case abnormal accumulation of the tracer was visualized in the region of the aortic valve. Three types of cardiac scintigraphic patterns were demonstrated: focal, multifocal, and extensive, each correlating well with the anatomical extent of the lesion as defined by gross pathology. Tissue distribution studies demonstrated a 30 +- 5.3 (mean +- SEM) fold excess of radionuclide uptake in the infective endocarditis lesion compared with that of normal myocardium. Imaging of excised hearts from four animals showed an excellent correlation with in vivo imaging as well as gross pathology. Five animals with nonbacterial thrombotic aortic valve endocarditis demonstrated similar scintigraphic and tissue distribution results. In contrast, four normal animals failed to demonstrate abnormal /sup 99m/Tc-PYP cardiac scintigrams or tissue uptake. This study demonstrates that /sup 99m/Tc-PYP cardiac scintigraphy is a sensitive technique to detect experimental aortic valve endocarditis

  20. Scintigraphic characteristics of experimental myocardial infarct extension

    International Nuclear Information System (INIS)

    Kronenberg, M.W.; Wooten, N.E.; Friesinger, G.C.; Page, D.L.; Higgins, S.B.; Collins, J.C.; O'Connor, J.L.; Price, R.R.; Brill, A.B.

    1979-01-01

    Technetium-99m-stannous pyrophosphate scintiphotos were evaluated for diagnosing and quantitating myocardial infarct (MI) extension in sedated dogs. Infarction and extension were produced by serial left anterior descending coronary artery ligations at 0 and 48 hours. We compared serial scintiphoto data with regional myocardial blood flow (MBF) (microsphere technique) and infarct histopathology. In eight control dogs, the scintigraphic MI area was stable at 24, 48, and 72 hours. In each of 11 dogs undergoing extension, the MI area increased after the 48-hour occlusion, averaging a 48.9% increase (p < 0.001). Grossly, most extensions were mixtures of confluent necrosis and moderate (patchy) necrosis. MBF to confluent infarct tissue decreased significantly, allowing the documentation of extension by totaling the grams of newly flow-deprived tissue, but patchy infarct tissue had little flow deprivation, making it difficult to quantitate this type of extension accurately by flow criteria alone. Rarely, extension could be diagnosed using conventional histologic criteria. We concluded that the scintiphoto MI area was related quantitatively to infarct weight in both control and extension. However, it was not possible to determine that an increase in the MI scintiphoto area was an accurate predictor of the degree of extension using independent flow or pathologic criteria

  1. The Role of Thiamine Pyrophosphate in Prevention of Cisplatin Ototoxicity in an Animal Model

    Directory of Open Access Journals (Sweden)

    Ozan Kuduban

    2013-01-01

    Full Text Available Objective. The aim of this study was to evaluate the effectiveness of thiamine pyrophosphate against cisplatin-induced ototoxicity in guinea pigs. Materials and Methods. Healthy guinea pigs (n=18 were randomly divided into three groups. Group 1 (n=6 received an intraperitoneal injection of saline solution and cisplatin for 7 days, group 2 (n=6 received an intraperitoneal injection of thiamine pyrophosphate and cisplatin for 7 days, and group 3 (n=6 received only intraperitoneal injection of saline for 7 days. The animals in all groups were sacrificed under anesthesia, and their cochleas were harvested for morphological and biochemical observations. Results. In group 1, receiving only cisplatin, cochlear glutathione concentrations, superoxide dismutase, and glutathione peroxidase activities significantly decreased (P<0.05 and malondialdehyde concentrations significantly increased (P<0.05 compared to the control group. In group 2, receiving thiamine pyrophosphate and cisplatin, the concentrations of enzymes were near those of the control group. Microscopic examination showed that outer hair cells, spiral ganglion cells, and stria vascularis were preserved in group 2. Conclusion. Systemic administration of thiamine pyrophosphate yielded statistically significant protection to the cochlea of guinea pigs from cisplatin toxicity. Further experimental animal studies are essential to determine the appropriate indications of thiamine pyrophosphate before clinical use.

  2. Central role of pyrophosphate in acellular cementum formation.

    Directory of Open Access Journals (Sweden)

    Brian L Foster

    Full Text Available Inorganic pyrophosphate (PP(i is a physiologic inhibitor of hydroxyapatite mineral precipitation involved in regulating mineralized tissue development and pathologic calcification. Local levels of PP(i are controlled by antagonistic functions of factors that decrease PP(i and promote mineralization (tissue-nonspecific alkaline phosphatase, Alpl/TNAP, and those that increase local PP(i and restrict mineralization (progressive ankylosis protein, ANK; ectonucleotide pyrophosphatase phosphodiesterase-1, NPP1. The cementum enveloping the tooth root is essential for tooth function by providing attachment to the surrounding bone via the nonmineralized periodontal ligament. At present, the developmental regulation of cementum remains poorly understood, hampering efforts for regeneration. To elucidate the role of PP(i in cementum formation, we analyzed root development in knock-out ((-/- mice featuring PP(i dysregulation.Excess PP(i in the Alpl(-/- mouse inhibited cementum formation, causing root detachment consistent with premature tooth loss in the human condition hypophosphatasia, though cementoblast phenotype was unperturbed. Deficient PP(i in both Ank and Enpp1(-/- mice significantly increased cementum apposition and overall thickness more than 12-fold vs. controls, while dentin and cellular cementum were unaltered. Though PP(i regulators are widely expressed, cementoblasts selectively expressed greater ANK and NPP1 along the root surface, and dramatically increased ANK or NPP1 in models of reduced PP(i output, in compensatory fashion. In vitro mechanistic studies confirmed that under low PP(i mineralizing conditions, cementoblasts increased Ank (5-fold and Enpp1 (20-fold, while increasing PP(i inhibited mineralization and associated increases in Ank and Enpp1 mRNA.Results from these studies demonstrate a novel developmental regulation of acellular cementum, wherein cementoblasts tune cementogenesis by modulating local levels of PP(i, directing and

  3. Thermoluminescence of cerium and terbium -doped calcium pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Roman L, J.; Cruz Z, E. [UNAM, Instituto de Ciencias Nucleares, Circuito Exterior, Ciudad Universitaria, 04510 Mexico D. F. (Mexico); Lozano R, I. B.; Diaz G, J. A. I., E-mail: jesus.roman@nucleares.unam.mx [IPN, Centro de Investigacion en Ciencia Aplicada y Tecnologia Avanzada, Av. Legaria No. 694, 11500 Mexico D. F. (Mexico)

    2015-10-15

    The aim of this work is to report the thermoluminescence (Tl) response of Calcium Pyrophosphate phosphor doped with Cerium and Terbium impurities (Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+}). The phosphors were synthesized using the co-precipitation method and annealed at 900 degrees C by two hours for obtain the β phase. The intentional doping with Ce and Tb ions was 1 at.% and 0.1 at.%, whereas in the EDS results the concentration of impurities was 0.39 at.% and 0.05 at.%, respectively. The superficial morphology of phosphor is mainly composed by thin wafers of different size. All samples were exposed to gamma rays from {sup 60}Co in the Gammacell-200 irradiator. The Tl response of the phosphor was measured from Rt up to 350 degrees C and under nitrogen atmosphere in a Harshaw TLD 3500 reader. The glow curves of the Ca{sub 2}P{sub 2}O{sub 7}:Ce{sup 3+},Tb{sup 3+} powders showed a broad intense Tl peak centered at 165 degrees C and a shoulder at approximate 260 degrees C was observed. A linear Tl response in the range of absorbed dose of 0.2 to 10 Gy was obtained. Tl glow curves were analyzed using the initial rise (IR)and computerized glow curve deconvolution methods to evaluate the kinetics parameters such as activation energy (E), frequency factor (s) and kinetic order (b). (Author)

  4. Significance of Tc-99m pyrophosphate accumulation in unstable angina

    International Nuclear Information System (INIS)

    Tange, Shoichi; Kondo, Chisato; Ohta, Yoshiko; Kusakabe, Kiyoko; Shigeta, Akiko; Uchida, Tatsuro; Sumiyoshi, Tetsuya; Kaneko, Noboru; Hosoda, Saichi

    1993-01-01

    Tc-99m pyrophosphate (PYP) and Tl-201 simultaneous dual energy single photon emission computed tomography (SPECT) were performed in 33 patients with clinically unstable angina. According to the presence or absence of PYP accumulation in the myocardium, the patients were classified as PYP (+) group (n=22) and PYP (-) group (n=11). Clinical features, types of unstable angina, ECG changes, and serial creatine kinase (CK) data were compared in the two groups. The 'new angina at rest' type of unstable angina was more significantly common in the PYP (+) group (16/22) than the PYP (-) group (2/11). The remaining 6 patients in the PYP (+) group and 2 patients in the PYP (-) group had 'angina of effort with changing pattern'. There was a significant difference in the occurrence of ST elevation and ST depression between the group: 59% in the PYP (+) group vs. 18% in the PYP (-) group for ST elevation and 23% in the PYP (+) group vs. 64% in the PYP (-) group for ST depression. The PYP (+) group showed significant improvement in ejection fraction in the stable state (57±12%) as compared with the unstable state (62±11%), although there was no difference between the stable and unstable state in the PYP (-) group. Although wall motion abnormality index (WMI) was poorer in the PYP (+) group than the PYP (-) group, it improved to the same degree as the PYP (-) group one month later. These data suggest that the area showing PYP (+) may reflect stunned myocardium and that Tc-99m PYP accumulation may correlate with clinical features of unstable angina. (N.K.)

  5. Automatic Detection of Myocardial Boundaries in MR Cardio Perfusion Images

    NARCIS (Netherlands)

    Spreeuwers, Luuk; Breeuwer, Marcel

    2001-01-01

    Cardiovascular diseases often result in reduced blood perfusion of the myocardium (MC). Recent advances in MR allow fast recordingof contrast enhanced myocardial perfusion scans. For perfusion analysis the myocardial boundaries must be traced. Currently this is done manually. In this paper a method

  6. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    International Nuclear Information System (INIS)

    Patel, R.; Mishkin, F.S.

    1986-01-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal

  7. Technetium-99m pyrophosphate imaging in acute renal failure associated with nontraumatic rhabdomyolysis

    Energy Technology Data Exchange (ETDEWEB)

    Patel, R.; Mishkin, F.S.

    1986-10-01

    Technetium-99m pyrophosphate (Tc-PYP) imaging was performed in five patients with acute renal failure associated with nontraumatic rhabdomyolysis. Four patients had phencyclidine intoxication and one had viral pneumonia. During the acute phase, marked uptake of pyrophosphate was seen in all patients in several muscle groups, but always in the thigh adductors. The results show that phencyclidine intoxication can result in diffuse muscle uptake of Tc-PYP without overt evidence of muscle injury. Tc-PYP imaging may provide a clue to the cause of acute renal failure in patients with suspected rhabdomyolysis in whom elevations of serum creatine phosphokinase concentrations are equivocal.

  8. Myocardial perfusion in silent myocardial ischemia

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1989-01-01

    To investigate myocardial perfusion in silent myocardial ischemia, we performed exercise stress myocardial tomography with thallium-201 (Tl) in 85 patients with coronary artery disease (CAD). Exercise stress myocardial tomography was obtained both immediately after exercise and three hours later. Patients were classified into two groups according to the presence (Symptomatic Group, n=36) or absence (Silent Group, n=49) of chest pain during exercise stress. Clinical features (age, gender and history of myocardial infarction) and arteriographically determined severity of CAD were the same in both groups. The extent of myocardial ischemia (% Ischemia) estimated by exercise stress myocardial tomography was the same in each group (30±10 % in Silent Group, 28±12 % in Symptomatic Group, NS). The severity of exercise-induced myocardial ischemia was expressed as a minimal value of myocardial Tl washout rate (minimal WOR) of each patient. Although exercise heart rate was identical in both groups, minimal WOR in Silent Group was significantly higher than that of Symptomatic Group (4±10% vs -16±14%, p<0.001). The study in patients who exhibited both silent and symptomatic ischemia showed the same results. These findings suggest that the severity of ischemia is a fundamental factor in determining the presence or absence of pain during exercise induced ischemia. (author)

  9. Biosynthesis of monoterpenes. Enantioselectivity in the enzymatic cyclization of (+)- and (-)-linalyl pyrophosphate to (+)- and (-)-pinene and (+)- and (-)-camphene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Cane, D.E.; Chang, C.C.

    1988-01-01

    Cyclase I from Salvia officinalis leaf catalyzes the conversion of geranyl pyrophosphate to the stereo-chemically related bicyclic monoterpenes (+)-alpha-pinene and (+)-camphene and to lesser quantities of monocyclic and acyclic olefins, whereas cyclase II from this plant tissue converts the same acyclic precursor to (-)-alpha-pinene, (-)-beta-pinene and (-)-camphene as well as to lesser amounts of monocyclics and acyclics. These antipodal cyclizations are considered to proceed by the initial isomerization of the substrate to the respective bound tertiary allylic intermediates (-)-(3R)- and (+)-(3S)-linalyl pyrophosphate. [(3R)-8,9-14C,(3RS)-1E-3H]Linalyl pyrophosphate (3H:14C = 5.14) was tested as a substrate with both cyclases to determine the configuration of the cyclizing intermediate. This substrate with cyclase I yielded alpha-pinene and camphene with 3H:14C ratios of 3.1 and 4.2, respectively, indicating preferential, but not exclusive, utilization of the (3R)-enantiomer. With cyclase II, the doubly labeled substrate gave bicyclic olefins with 3H:14C ratios of from 13 to 20, indicating preferential, but not exclusive, utilization of the (3S)-enantiomer in this case. (3R)- and (3S)-[1Z-3H]linalyl pyrophosphate were separately compared to the achiral precursors [1-3H]geranyl pyrophosphate and [1-3H]neryl pyrophosphate (cis-isomer) as substrates for the cyclizations. With cyclase I, geranyl, neryl, and (3R)-linalyl pyrophosphate gave rise exclusively to (+)-alpha-pinene and (+)-camphene, whereas (3S)-linayl pyrophosphate produced, at relatively low rates, the (-)-isomers. With cyclase II, geranyl, neryl, and (3S)-linalyl pyrophosphate yielded exclusively the (-)-isomer series, whereas (3R)-linalyl pyrophosphate afforded the (+)-isomers at low rates

  10. Multiparametric approach to diagnosis of non-Q-wave acute myocardial infarction

    International Nuclear Information System (INIS)

    Carpeggiani, C.; L'Abbate, A.; Marzullo, P.

    1989-01-01

    The present study investigated whether the lack of enzyme increase is reason enough to exclude necrosis in patients with ischemic heart disease who develop electrocardiographic sustained ST-T changes in the absence of Q waves. In 15 consecutive patients with angina who developed sustained ST-T changes during hospitalization, the presence of myocardial necrosis was investigated by a prospective multiparametric approach. Serum enzymes and myoglobin, pyrophosphate uptake, 2-dimensional echocardiography, perfusion scintigraphy, left ventriculography and coronary angiography were evaluated. According to creatine kinase and creatine kinase-MB peak at twice the upper normal value, the diagnosis of acute myocardial infarction applied only to 40% of patients. However, myoglobin was positive in 80% and a perfusion defect could be documented by an electrocardiographic gated microsphere technique in 100% of patients. The positivity of myoglobin increased to 100% and of creatine kinase and creatine kinase-MB to 87 and 60%, respectively, when a peak value twice the individual lowest value was considered for positivity. The 100% presence of perfusion defects associated with the high prevalence of both positive pyrophosphate uptake (87%) and regional dyssynergies (87 and 73%, respectively, by left ventriculography and echocardiography) strongly suggest that sustained (greater than or equal to 7 days) ST-T changes in this population were indicative of myocardial necrosis. Thus, by conventional enzymatic approach, diagnosis of non-Q-wave infarction can be missed in a sizable number of patients and present important clinical implications

  11. Kinetics of sup(99m)Tc-pyrophosphate in comparison with 85Sr in acutely and chronically altered soft part and bone regions

    International Nuclear Information System (INIS)

    Buell, U.; Balser, D.; Boehner-Schoberth, I.; Frey, K.W.; Muenchen Univ.; Muenchen Univ.

    1974-01-01

    Summarizing our findings, we can state that *Tc-pyrophosphate concentrates in acutely inflammated soft tissue and some malignant soft-tissue tumors. In comparison with *Sr, Tc-pyrophosphate concentration is relatively higher but absolute concentration does not exceed the Sr concentration up to 3 hours post injection. 24 hours after injection we found a significantly higher *Tc-PyP concentration in all soft tissues, whether inflammated or not, pure muscle excluded. These findings correlate well with the collagen contents in the tissues, which is underlined by the fact that the highest *Tc-PyP concentration in normal soft tissue examined has been found in the patellar tendon. In rheumatic arthritis the positive joint scan with *Tc-PyP could be due to the damaged soft tissue only, even when bone destruction is evident. In humans bearing osteoarthritis of the hip joint we found a threefold higher concentration of *Tc-PyP in the joint capsule compared with the muscle. 85 Sr concentration was twice as high. (orig.) [de

  12. Classification of myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Hosbond, Susanne Elisabeth

    2013-01-01

    The classification of myocardial infarction into 5 types was introduced in 2007 as an important component of the universal definition. In contrast to the plaque rupture-related type 1 myocardial infarction, type 2 myocardial infarction is considered to be caused by an imbalance between demand...

  13. Determination of pyrophosphate and sulfate using polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles.

    Science.gov (United States)

    Terenteva, E A; Apyari, V V; Dmitrienko, S G; Garshev, A V; Volkov, P A; Zolotov, Yu A

    2018-04-01

    Positively charged polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles (PHMG-AgNPs) were prepared and applied as a colorimetric probe for single-step determination of pyrophosphate and sulfate. The approach is based on the nanoparticles aggregation leading to change in their absorption spectra and color of the solution. Due to both electrostatic and steric stabilization these nanoparticles show decreased sensitivity relatively to many common anions, which allows for simple and rapid direct single-step determination of pyrophosphate and sulfate. Effects of different factors (time of interaction, pH, concentrations of anions and the nanoparticles) on aggregation of PHMG-AgNPs and analytical performance of the procedure were investigated. The method allows for the determination of pyrophosphate and sulfate in the range of 0.16-2μgmL -1 and 20-80μgmL -1 with RSD of 2-5%, respectively. The analysis can be performed using either spectrophotometry or naked-eye detection. Practical application of the method was shown by the example of pyrophosphate determination in baking powder sample. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Stabilization through precipitation in a system of colloidal iron(III) pyrophosphate salts

    NARCIS (Netherlands)

    van Leeuwen, Y.M.; Velikov, K.P.; Kegel, W.K.

    2012-01-01

    The ionic strength of a solution decreases during the precipitation of an insoluble salt, which can cause an initially unstable colloidal system to stabilize during its formation. We show this effect in the precipitation and aging of colloidal iron(III) pyrophosphate, where we observe two distinct

  15. Hyaline cartilage involvement in patients with gout and calcium pyrophosphate deposition disease. An ultrasound study.

    Science.gov (United States)

    Filippucci, E; Riveros, M Gutierrez; Georgescu, D; Salaffi, F; Grassi, W

    2009-02-01

    The main aim of the present study was to determine the sensitivity, specificity and accuracy of ultrasonography (US) in detecting monosodium urate and calcium pyrophosphate dihydrate crystals deposits at knee cartilage level using clinical definite diagnosis as standard reference. A total of 32 patients with a diagnosis of gout and 48 patients with pyrophosphate arthropathy were included in the study. Fifty-two patients with rheumatoid arthritis (RA), psoriatic arthritis or osteoarthritis (OA) were recruited as disease controls. All diagnoses were made using an international clinical criterion. US examinations were performed by an experienced sonographer, blind to clinical and laboratory data. Hyaline cartilage was assessed to detect two US findings recently indicated as indicative of crystal deposits: hyperechoic enhancement of the superficial margin of the hyaline cartilage and hyperechoic spots within the cartilage layer not generating a posterior acoustic shadow. Hyperechoic enhancement of the chondrosynovial margin was found in at least one knee of 14 out of 32 (43.7%) patients with gout and in a single knee of only one patient affected by pyrophosphate arthropathy (specificity=99%). Intra-cartilaginous hyperechoic spots were detected in at least one knee of 33 out of 48 (68.7%) patients with pyrophosphate arthropathy and in two disease controls one with OA and the second with RA (specificity=97.6%). The results of the present study indicate that US may play a relevant role in distinguishing cartilage involvement in patients with crystal-related arthropathy. The selected US findings were found to be highly specific.

  16. Sensor Function for Butyrophilin 3A1 in Prenyl Pyrophosphate Stimulation of Human Vγ2Vδ2 T Cells

    Science.gov (United States)

    Wang, Hong; Morita, Craig T.

    2016-01-01

    Vγ2Vδ2 T cells play important roles in human immunity to pathogens and in cancer immunotherapy by responding to isoprenoid metabolites, such as (E)-4-hydroxy-3-methyl-but-2-enyl pyrophosphate and isopentenyl pyrophosphate. The Ig superfamily protein butyrophilin (BTN)3A1 was shown to be required for prenyl pyrophosphate stimulation. We proposed that the intracellular B30.2 domain of BTN3A1 binds prenyl pyrophosphates, resulting in a change in the extracellular BTN3A1 dimer that is detected by Vγ2Vδ2 TCRs. Such B30.2 binding was demonstrated recently. However, other investigators reported that the extracellular BTN3A1 IgV domain binds prenyl pyrophosphates, leading to the proposal that the Vγ2Vδ2 TCR recognizes the complex. To distinguish between these mechanisms, we mutagenized residues in the two binding sites and tested the mutant BTN3A1 proteins for their ability to mediate prenyl pyrophosphate stimulation of Vγ2Vδ2 T cells to proliferate and secrete TNF-α. Mutagenesis of residues in the IgV site had no effect on Vγ2Vδ2 T cell proliferation or secretion of TNF-α. In contrast, mutagenesis of residues within the basic pocket and surrounding V regions of the B30.2 domain abrogated prenyl pyrophosphate-induced proliferation. Mutations of residues making hydrogen bonds to the pyrophosphate moiety also abrogated TNF-α secretion, as did mutation of aromatic residues making contact with the alkenyl chain. Some mutations further from the B30.2 binding site also diminished stimulation, suggesting that the B30.2 domain may interact with a second protein. These findings support intracellular sensing of prenyl pyrophosphates by BTN3A1 rather than extracellular presentation. PMID:26475929

  17. Myocardial imaging. Coxsackie myocarditis

    Energy Technology Data Exchange (ETDEWEB)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-09-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1.

  18. Myocardial imaging. Coxsackie myocarditis

    International Nuclear Information System (INIS)

    Wells, R.G.; Ruskin, J.A.; Sty, J.R.

    1986-01-01

    A 3-week-old male neonate with heart failure associated with Coxsackie virus infection was imaged with Tc-99m PYP and TI-201. The abnormal imaging pattern suggested myocardial infarction. Autopsy findings indicated that the cause was myocardial necrosis secondary to an acute inflammatory process. Causes of abnormal myocardial uptake of Tc-99m PYP in pediatrics include infarction, myocarditis, cardiomyopathy, bacterial endocarditis, and trauma. Myocardial imaging cannot provide a specific cause diagnosis. Causes of myocardial infarction in pediatrics are listed in Table 1

  19. Comparison of radiation dosimetry for several potential myocardial imaging agents

    International Nuclear Information System (INIS)

    Watson, E.E.; Stabin, M.G; Goodman, M.M.; Knapp, F.F. Jr.; Srivastava, P.C.

    1986-01-01

    Although myocardial imaging is currently dominated by Tl-201, several alternative agents with improved physiologic or radionuclidic properties have been proposed. Based on human and animal studies in the literature, the metabolism of several of these compounds was studied for the purpose of generating radiation dose estimates. Dose estimates are listed for several I-123-labeled free fatty acids, an I-123-labeled phosphonium compound, Rb-82, Cu-64, F-18 FDG (all compounds which are taken up by the normal myocardium), and for Tc-99m pyrophosphate (PYP) (which localizes in myocardial infarcts). Dose estimates could not be generated for C-11 palmitate, but his compound was included in a comparison of myocardial retention times. For the I-123-labeled compounds, I-124 was included as a contaminant in generating the dose estimates. Radiation doses were lowest for Rb-82 (gonads 0.3-0.4 Gy/MBq, kidneys 8.6 Gy/MBq). Doses for the I-123-labeled fatty acids were similar to one another, with IPPA being the lowest (gonads 15 Gy/MBq, heart wall 18 Gy/MBq). Doses for Tc-99m PYP were also low (gonads 4-7 Gy/MBq, heart wall 4 Gy/MBq, skeleton 15 Gy/MBq). The desirability of these compounds is discussed briefly, considering half-life, imaging mode and energy, and dosimetry, including a comparison of the effective whole body dose equivalents. 37 references, 11 tables

  20. Effect of eating on thallium myocardial imaging

    International Nuclear Information System (INIS)

    Wilson, R.A.; Sullivan, P.J.; Okada, R.D.; Boucher, C.A.; Morris, C.; Pohost, G.M.; Strauss, H.W.

    1986-01-01

    To determine if eating between initial and delayed thallium images alters the appearance of the delayed thallium scan, a prospective study was performed; 184 subjects sent for routine thallium imaging were randomized into two groups, those who ate a meal high in carbohydrates between initial and delayed thallium myocardial images (n = 106), and those who fasted (n = 78). The 201 Tl images were interpreted in blinded fashion for global myocardial and pulmonary clearance of 201 Tl myocardial defects. The eating group had a significantly lower incidence of transient myocardial defects compared to the noneating group (7 percent vs 18 percent, respectively; p less than 0.05). The time between initial and delayed images and the incidence of exercise-induced ischemic ST-segment depression or pathologic Q waves on the electrocardiogram were not significantly different between the two groups. These data suggest that eating a high-carbohydrate meal between initial and delayed 201 Tl images causes increased 201 Tl myocardial clearance rates and may alter 201 Tl myocardial redistribution over time

  1. Flame-Retardant and Thermal Degradation Mechanism of Caged Phosphate Charring Agent with Melamine Pyrophosphate for Polypropylene

    Directory of Open Access Journals (Sweden)

    Xuejun Lai

    2015-01-01

    Full Text Available An efficient caged phosphate charring agent named PEPA was synthesized and combined with melamine pyrophosphate (MPP to flame-retard polypropylene (PP. The effects of MPP/PEPA on the flame retardancy and thermal degradation of PP were investigated by limiting oxygen index (LOI, vertical burning test (UL-94, cone calorimetric test (CCT, and thermogravimetric analysis (TGA. It was found that PEPA showed an outstanding synergistic effect with MPP in flame retardant PP. When the content of PEPA was 13.3 wt% and MPP was 6.7 wt%, the LOI value of the flame retardant PP was 33.0% and the UL-94 test was classed as a V-0 rating. Meanwhile, the peak heat release rate (PHRR, average heat release rate (AV-HRR, and average mass loss rate (AV-MLR of the mixture were significantly reduced. The flame-retardant and thermal degradation mechanism of MPP/PEPA was investigated by TGA, Fourier transform infrared spectroscopy (FTIR, TG-FTIR, and scanning electron microscopy-energy dispersive X-ray spectrometry (SEM-EDXS. It revealed that MPP/PEPA could generate the triazine oligomer and phosphorus-containing compound radicals which changed the thermal degradation behavior of PP. Meanwhile, a compact and thermostable intumescent char was formed and covered on the matrix surface to prevent PP from degrading and burning.

  2. Nuclear Scans

    Science.gov (United States)

    Nuclear scans use radioactive substances to see structures and functions inside your body. They use a special ... images. Most scans take 20 to 45 minutes. Nuclear scans can help doctors diagnose many conditions, including ...

  3. RubiShort: Reducing scan time in 82Rb heart scans to minimize movements artifacts

    DEFF Research Database (Denmark)

    Madsen, Jeppe; Vraa, Kaspar J.; Harms, Hans

    .013x, R2=0.98; %Reversible: y=1.008x, R2=0.95; TPD: y=1.000x, R2=0.99). Conclusion:, Scan time of myocardial perfusion scans using 82Rb can be reduced from 7 min. to 5 min. without loss of quantitative accuracy. Since patient motion is frequent in the last minutes of the scans, scan time reduction...

  4. Ligand-free, protein-bound technetium-99m iron-dextran enhancement of technetium pyrophosphate uptake in tumours

    International Nuclear Information System (INIS)

    Pojer, P.M.; Jakovljevic, A.C.; Wise, K.N.

    1985-01-01

    The biodistribution of technetium-99m was studied in T-cell lymphoma and selected organs of iron-dextran treated and control mice given technetium-99m pyrophosphate. The results showed that high serum iron levels increased tumour uptake of technetium pyrophosphate. This supports the hypothesis that technetium, in common with other metal-based tumour seeking radiopharmaceuticals, is transported to tumours as a ligand-free protein-bound cation. (U.K.)

  5. Application of radionuclide infarct scintigraphy to diagnose perioperative myocardial infarction following revascularization

    International Nuclear Information System (INIS)

    Klausner, S.C.; Botvinick, E.H.; Shames, D.; Ullyot, D.J.; Fishman, N.H.; Roe, B.B.; Ebert, P.A.; Chatterjee, K.; Parmley, W.W.

    1977-01-01

    To evaluate the application of radionuclide infarct scintigraphy to diagnose myocardial infarction after revascularization, we obtained postoperative technetium 99m pyrophosphate myocardial scintigrams, serial electrocardiograms and CPK-MB isoenzymes in ten control and 51 revascularized patients. All control patients had negative electrocardiograms and scintigrams, but eight had positive isoenzymes. Eight revascularized patients had positive electrocardiograms, images and enzymes and two had positive scintigrams and enzymes with negative electrocardiograms. Thirty-four patients with negative electrocardiograms and scintigrams had positive isoenzymes; in only seven patients were all tests negative. Our data suggest radionuclide infarct scintigraphy is a useful adjunct to the electrocardiogram in diagnosing perioperative infarction. The frequent presence of CPK-MB in postoperative patients without other evidence of infarction suggests that further studies are required to identify all factors responsible for its release

  6. Contribution of technetium 99m-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis

    International Nuclear Information System (INIS)

    Capdepont, M.-T.

    1976-01-01

    This work examines the contribution of technetium 99m(sup(99m)Tc)-labelled pyrophosphate bone scintigraphy in infectious spondylodiscitis and attempts to define its importance in the diagnosis of lesions and their subsequent supervision in patients under treatment. 5 to 15 millicuries of sup(99m)Tc-labelled pyrophosphates are injected intraveinously. Bone uptake is strong and durable; 1.3% of the injected activity is found in the blood by the fifth hour. The skeleton may be explored: - either one segment at a tome with a scintillation camera, - or all at once and more quickly with a whole-body device taking front and black exposures. Bone scintigraphy appears as a basic technique in the study of infectious spondylodiscitis. Moreover the use of increasingly efficient equipment, the quantification of results and perhaps the development of new tracers augur well for a technique which is already acknowledged to be of fundamental interest [fr

  7. Inositol pyrophosphates promote tumor growth and metastasis by antagonizing liver kinase B1

    Science.gov (United States)

    Rao, Feng; Xu, Jing; Fu, Chenglai; Cha, Jiyoung Y.; Gadalla, Moataz M.; Xu, Risheng; Barrow, James C.; Snyder, Solomon H.

    2015-01-01

    The inositol pyrophosphates, molecular messengers containing an energetic pyrophosphate bond, impact a wide range of biologic processes. They are generated primarily by a family of three inositol hexakisphosphate kinases (IP6Ks), the principal product of which is diphosphoinositol pentakisphosphate (IP7). We report that IP6K2, via IP7 synthesis, is a major mediator of cancer cell migration and tumor metastasis in cell culture and in intact mice. IP6K2 acts by enhancing cell-matrix adhesion and decreasing cell–cell adhesion. This action is mediated by IP7-elicited nuclear sequestration and inactivation of the tumor suppressor liver kinase B1 (LKB1). Accordingly, inhibitors of IP6K2 offer promise in cancer therapy. PMID:25617365

  8. Effect of intra-articular yttrium-90 on chronic pyrophosphate arthropathy of the knee

    International Nuclear Information System (INIS)

    Doherty, M.; Dieppe, P.A.

    1981-01-01

    Fifteen patients with bilateral, symmetrical chronic pyrophosphate arthropathy of the knee were given intra-articular injections of yttrium-90 (5 mCi) plus steroid (triamcinolone hexacetonide, 20 mg) into one knee, and saline plus steroid into the other (control) knee. Allocation of the 90 Y injection was random and double blind. After 6 months there was significantly less pain, inactivity stiffness, joint-line tenderness, and effusion in the 90 Y-injected knees than in the controls (p 90 Y-injected and control knees in the changes in range of movement (p 90 Y may be of benefit in chronic pyrophosphate arthropathy, a disease for which there is no treatment. The predilection of this condition to affect the knees of the elderly makes such treatment highly suitable because the joint lends itself readily to injection and the procedure carries very few actual or potential risks in this age group. (author)

  9. Identification of Farnesyl Pyrophosphate and N-Arachidonylglycine as Endogenous Ligands for GPR92*S⃞

    OpenAIRE

    Oh, Da Young; Yoon, Jung Min; Moon, Mi Jin; Hwang, Jong-Ik; Choe, Han; Lee, Ju Yeon; Kim, Jae Il; Kim, Sunoh; Rhim, Hyewhon; O'Dell, David K.; Walker, J. Michael; Na, Heung Sik; Lee, Min Goo; Kwon, Hyuk Bang; Kim, Kyungjin

    2008-01-01

    A series of small compounds acting at the orphan G protein-coupled receptor GPR92 were screened using a signaling pathway-specific reporter assay system. Lipid-derived molecules including farnesyl pyrophosphate (FPP), N-arachidonylglycine (NAG), and lysophosphatidic acid were found to activate GPR92. FPP and lysophosphatidic acid were able to activate both Gq/11- and Gs-mediated signaling pathways, whereas NAG activated only the Gq/11-mediated signaling pathway. Co...

  10. Effect of vitamin D3, other drugs altering serum calcium or phosphorus concentrations, and desoxycorticosterone on the distribution of Tc-99m pyrophosphate between target and nontarget tissues

    International Nuclear Information System (INIS)

    Carr, E.A. Jr.; Carroll, M.; Montes, M.

    1981-01-01

    Radioactive imaging agents are chemically designed for selective distribution. Another approach to selectivity is to find stable compounds that favorably influence this distribution. Using a rat model of myocardial necrosis, we studied effects of various stable compounds (as a single, large dose or fractionated into short series) on the ratio, uptake of Tc-99m pyrophosphate (PPi) by the target lesion/uptake by the principal nontarget, bone (L/B). Vitamin D3s ability to increase L/B was mediated by the hypercalcemia and hyperphosphatemia that it caused. The hypercalcemia was accompanied by increased [Ca] in the lesion. In contrast, pulse doses of desoxycorticosterone acetate (DOCA) at 7 and 6 hr before killing increased uptake by lesion, increasing L/B from 0.19 +/- 0.03 to 0.45 +/- 0.08 (p less than 0.01), with no change in serum [Ca] and minimal changes in serum [P], [Na], and [K]. DOCA also increased the lesion-to-blood ratio from 6.5 +/- 0.07 to 15.4 +/- 3.9 (p less than 0.05). These results encourage further study of DOCA's effect and investigation of other stable drugs that may influence distribution of other imaging agents

  11. Effect of eating on thallium-201 myocardial redistribution after myocardial ischemia

    International Nuclear Information System (INIS)

    Angello, D.A.; Wilson, R.A.; Palac, R.T.

    1987-01-01

    To determine whether eating a high-carbohydrate meal between initial and delayed postexercise thallium-201 (Tl-201) imaging affects detection of Tl-201 redistribution during exercise stress testing, 16 patients with stable angina performed 2 Tl-201 treadmill exercise stress tests within a 14-day interval. Immediately after initial postexercise imaging, patients either drank a commercially available instant breakfast preparation for the intervention test or drank an equivalent volume of water for the control test. Comparable exercise workloads were achieved by exercising patients to the same heart rate for both tests. The order of the 2 (intervention and control) tests were randomized. All patients had at least 1 region of Tl-201 myocardial redistribution on either their eating or control test scans, although only 7 of the 16 had positive treadmill exercise test responses. Forty-six regions showing Tl-201 myocardial redistribution were identified in all 144 regions examined. Significantly more of these regions were identified on control test scans than on eating test scans: 11 of 46 on both test scans, 6 of 46 only on eating test scans and 29 of 46 only on control scans (p less than 0.001). Consistent with results of the quantitative regional analysis, the percentage of Tl-201 clearance over 4 hours in the 46 Tl-201 myocardial redistribution regions was 39 +/- 8% for the eating tests and 29 +/- 8% for control tests (mean +/- standard deviation, p less than 0.003). In 4 patients diagnosis of transient ischemia would have been missed because their 14 Tl-201 myocardial redistribution regions were detected only on the control test scans

  12. Exercise induced ST elevation and residual myocardial ischemia in previous myocardial infarction

    International Nuclear Information System (INIS)

    Shimonagata, Tsuyoshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Saito, Muneyasu; Sumiyoshi, Tetsuya

    1987-01-01

    The purpose of this study was to evaluate the clinical significance of stress induced ST elevation on infarcted area in 65 patients with previous myocardial infarction (single vessel disease) who had stress thallium scan. Stress induced ST changes on infarcted area were compared with quantitative assessment of myocardial ischemia (thallium ischemic score; TIS) and extent of myocardial infarction (defect score; DS) derived from circumferential profile analysis. In patients with previous myocardial infarction in less than 3 month from the onset (n = 36), left ventricular ejection fraction (LVEF) and extent of abnormal LV wall motion were not significantly different between patients with stress induced ST elevation ( ≥ 2 mm, n = 26) and those with stress induced ST elevation ( < 2 mm, n = 10), while, in patients with previous myocardial infarction in more than 3 month (n = 29), patients with stress induced ST elevation ( ≥ 2 mm, n = 15) showed left ventricular dyskinesis more frequently than those with ST elevation ( < 2 mm, n = 14). In addition, the former showed significantly higher DS and significantly lower TIS than the latter. In patients with previous myocardial infarction in less than 3 month, patients with ST elevation ( ≥ 2 mm, n = 15) with prominent upright T wave (n = 15) had transient thallium defect in infarcted area in 73 % and they had significantly higher LVEF and TIS than those with ST elevation ( < 2 mm, n = 11). These results indicated that ST elevation in infarcted area reflect different significance according to the recovery of injured myocardium and stress induced ST elevation with prominent upright T wave in infarcted area reflect residual myocardial ischemia in less than 3 month from the onset of myocardial infarction. (author)

  13. Biosynthesis of monoterpenes. Stereochemistry of the enzymatic cyclizations of geranyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene

    International Nuclear Information System (INIS)

    Croteau, R.; Satterwhite, D.M.; Wheeler, C.J.; Felton, N.M.

    1989-01-01

    The conversion of geranyl pyrophosphate to (+)-alpha-pinene and to (-)-beta-pinene is considered to proceed by the initial isomerization of the substrate to (-)-(3R)- and to (+)-(3S)-linalyl pyrophosphate, respectively, and the subsequent cyclization of the anti, endo-conformer of these bound intermediates by mirror-image sequences which should result in the net retention of configuration at C1 of the geranyl precursor. Incubation of (1R)-[2-14C,1-3H]- and (1S)-[2-14C,1-3H]geranyl pyrophosphate with (+)-pinene cyclase and with (-)-pinene cyclase from common sage (Salvia officinalis) gave labeled (+)-alpha- and (-)-beta-pinene of unchanged 3H/14C ratio in all cases, and the (+)- and (-)-olefins were stereoselectively converted to (+)- and (-)-borneol, respectively, which were oxidized to the corresponding (+)- and (-)-isomers of camphor, again without change in isotope ratio. The location of the tritium was determined in each case by stereoselective, base-catalyzed exchange of the exo-alpha-hydrogens of these derived ketones. The results indicated that the configuration at C1 of the substrate was retained in the enzymatic transformations to the (+)- and (-)-pinenes, which is entirely consistent with the syn-isomerization of geranyl pyrophosphate to linalyl pyrophosphate, transoid to cisoid rotation, and anti, endo-cyclization of the latter. The absolute stereochemical elements of the antipodal reaction sequences were confirmed by the selective enzymatic conversions of (3R)- and (3S)-1Z-[1-3H]linalyl pyrophosphate to (+)-alpha-pinene and (-)-beta-pinene, respectively, and by the location of the tritium in the derived camphors as before. The summation of the results fully defines the overall stereochemistry of the coupled isomerization and cyclization of geranyl pyrophosphate to the antipodal pinenes

  14. Renal scan

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/003790.htm Renal scan To use the sharing features on this ... anaphylaxis . Alternative Names Renogram; Kidney scan Images Kidney anatomy Kidney - blood and urine flow References Chernecky CC, ...

  15. CT Scan

    Science.gov (United States)

    ... disease, lung nodules and liver masses Monitor the effectiveness of certain treatments, such as cancer treatment Detect ... scan done in a hospital or an outpatient facility. CT scans are painless and, with newer machines, ...

  16. Periodontitis and myocardial hypertrophy.

    Science.gov (United States)

    Suzuki, Jun-Ichi; Sato, Hiroki; Kaneko, Makoto; Yoshida, Asuka; Aoyama, Norio; Akimoto, Shouta; Wakayama, Kouji; Kumagai, Hidetoshi; Ikeda, Yuichi; Akazawa, Hiroshi; Izumi, Yuichi; Isobe, Mitsuaki; Komuro, Issei

    2017-04-01

    There is a deep relationship between cardiovascular disease and periodontitis. It has been reported that myocardial hypertrophy may be affected by periodontitis in clinical settings. Although these clinical observations had some study limitations, they strongly suggest a direct association between severity of periodontitis and left ventricular hypertrophy. However, the detailed mechanisms between myocardial hypertrophy and periodontitis have not yet been elucidated. Recently, we demonstrated that periodontal bacteria infection is closely related to myocardial hypertrophy. In murine transverse aortic constriction models, a periodontal pathogen, Aggregatibacter actinomycetemcomitans markedly enhanced cardiac hypertrophy with matrix metalloproteinase-2 activation, while another pathogen Porphyromonas gingivalis (P.g.) did not accelerate these pathological changes. In the isoproterenol-induced myocardial hypertrophy model, P.g. induced myocardial hypertrophy through Toll-like receptor-2 signaling. From our results and other reports, regulation of chronic inflammation induced by periodontitis may have a key role in the treatment of myocardial hypertrophy. In this article, we review the pathophysiological mechanism between myocardial hypertrophy and periodontitis.

  17. Studies on the mechanism of pyrophosphate-mediated uptake of iron from transferrin by isolated rat-liver mitochondria

    International Nuclear Information System (INIS)

    Konopka, K.; Romslo, I.; Bergen Univ.

    1981-01-01

    1. Respiring rat liver mitochondria accumulate iron released from transferrin by pyrophosphate. The amount of iron accumulated is 1-1.5 nmol mg protein -1 h -1 , or approximately 60% of the amount of iron mobilized from transferrin. 2. The uptake declines if respiration is inhibited, substrate is depleted, or the experiments are run under anaerobic conditions. Substrate, depletion and respiratory inhibitors are less inhibitory under anaerobic conditions. 3. More than 80% of the amount of iron accumulated by aerobic, actively respiring mitochondria can be chelated by bathophenanthroline sulphonate, and with deuteroporphyrin included, up to 30% of the amount of iron accumulated is recovered as deuteroheme. Iron accumulated by respiration-inhibited mitochondria under aerobic conditions is not available for heme synthesis. 4. With time the uptake of iron increases eightfold relative to the uptake of pyrophosphate. 5. The results are compatible with a model in which ferric iron is mobilized from transferrin by pyrophosphate, ferric iron pyrophosphate is bound to the mitochondria, iron is reduced, dissociates from pyrophosphate and is taken up by the mitochondria. Ferrous irons thus formed is available for heme synthesis. (orig.) [de

  18. Effect of coronary artery recanalization on right ventricular function in patients with acute myocardial infarction

    International Nuclear Information System (INIS)

    Verani, M.S.; Tortoledo, F.E.; Batty, J.W.; Raizner, A.E.

    1985-01-01

    The effects of coronary artery recanalization by intracoronary administration of streptokinase on left ventricular function during acute myocardial infarction have received increasing attention in recent years. Although myocardial dysfunction is often more pronounced in the right ventricle than in the left ventricle in patients with acute inferior wall myocardial infarction, the effect of coronary artery recanalization on right ventricular dysfunction has not been previously addressed. Accordingly, in this investigation, 54 patients who participated in a prospective, controlled, randomized trial of recanalization during acute myocardial infarction were studied. Among 30 patients with inferior wall infarction, 19 had right ventricular dysfunction on admission; 11 of these 19 had positive uptake of technetium-99m pyrophosphate in the right ventricle, indicative of right ventricular infarction. Patients with successful recanalization exhibited improved right ventricular ejection fraction from admission to day 10. However, control patients and patients who did not undergo recanalization also exhibited improvement. These data indicate that the right ventricular dysfunction commonly associated with inferior wall infarction is often transient, and improvement is the rule, irrespective of early recanalization of the infarct vessel

  19. Normal results of post-race thallium-201 myocardial perfusion imaging in marathon runners with elevated serum MB creatine kinase levels

    International Nuclear Information System (INIS)

    Siegel, A.J.; Silverman, L.M.; Holman, B.L.

    1985-01-01

    Elevated cardiac enzyme values in asymptomatic marathon runners after competition can arise from skeletal muscle through exertional rhabdomyolysis, silent injury to the myocardium, or a combined tissue source. Peak post-race levels of the MB isoenzyme of creatine kinase are similar to values in patients with acute myocardial infarction. Previously reported normal results of infarct-avid myocardial scintigraphy with technetium 99m pyrophosphate in runners after competition suggest a non-cardiac source but cannot exclude silent injury to the myocardium. Therefore, thallium 201 myocardial perfusion imaging was performed in runners immediately after competition together with determination of sequential cardiac enzyme levels. Among 15 runners tested, the average peak in serum MB creatine kinase 24 hours after the race was 128 IU/liter with a cumulative MB creatine kinase release of 117 IU/liter; these values are comparable to those in patients with acute transmural myocardial infarction. Thallium 201 myocardial scintigraphic results were normal in five runners randomly selected from those who volunteered for determination of sequential blood levels. It is concluded that elevations of serum MB creatine kinase in marathon runners arise from a skeletal muscle source and that thallium 201 myocardial scintigraphy is useful to assess runners for myocardial injury when clinical questions arise

  20. Potent inhibition of mammalian ribonucleases by 3', 5'-pyrophosphate-linked nucleotides.

    Science.gov (United States)

    Russo, N; Shapiro, R

    1999-05-21

    Molecular modeling based on the crystal structure of the complex of bovine pancreatic RNase A with the inhibitor 5'-diphosphoadenosine 3'-phosphate (ppAp) (Leonidas, D. D., Shapiro, R., Irons, L. I., Russo, N., and Acharya, K. R. (1997) Biochemistry 36, 5578-5588) was used to design new inhibitors that extend into unoccupied regions of the enzyme active site. These compounds are dinucleotides that contain an unusual 3',5'-pyrophosphate linkage and were synthesized in solution by a combined chemical and enzymatic procedure. The most potent of them, 5'-phospho-2'-deoxyuridine 3'-pyrophosphate, P' --> 5'-ester with adenosine 3'-phosphate (pdUppAp), binds to RNase A with Ki values of 27 and 220 nM at pH 5.9 and 7, respectively. These values are 6-9-fold lower than those for ppAp and 50-fold lower than that for the transition state analogue, uridine vanadate. pdUppAp has broad specificity; it is an effective inhibitor of at least two other members of the pancreatic RNase superfamily, human RNase-2 (eosinophil-derived neurotoxin) and RNase-4, which share only 36-44% sequence identity with the pancreatic enzyme. The potency of pdUppAp and the other inhibitors described here depends critically on the extended internucleotide linkage; the pyrophosphate group enhances dinucleotide binding to the three RNases by 2.1-2.9 orders of magnitude, as compared with a monophosphate. These data give further insight into the organization of the catalytic centers of the various RNases. Moreover, the new class of inhibitors provides a useful means by which to probe the biological actions of these and other related enzymes.

  1. Rapid efflux of Ca2+ from heart mitochondria in the presence of inorganic pyrophosphate.

    Science.gov (United States)

    Vercesi, A; Lehninger, A L

    1984-01-13

    Inorganic pyrophosphate (PPi) in the intracellular concentration range causes rapid efflux of Ca2+ from rat heart mitochondria oxidizing pyruvate + malate in a low Na+ medium. Half-maximal rates of Ca2+ efflux were given by 20 microM PPi. During and after PPi-stimulated Ca2+ efflux the mitochondria retain their structural integrity and complete respiratory control. Carboxyatractyloside inhibits PPi-stimulated Ca2+ efflux, indicating PPi must enter the matrix in order to promote Ca2+ efflux. Heart mitochondria have a much higher affinity for PPi uptake and PPi-induced Ca2+ efflux than liver mitochondria.

  2. Gitelman syndrome disclosed by calcium pyrophosphate deposition disease: early diagnosis by ultrasonographic study

    Directory of Open Access Journals (Sweden)

    A. Zabotti

    2016-06-01

    Full Text Available Gitelman’s syndrome is a rare autosomal-recessive tubular disorder characterized by hypomagnesemia and hypocalciuria associated to hypokalemia. The clinical spectrum is wide and usually characterized by chronic fatigue, cramps, muscle weakness and paresthesiae. We describe a case of a 43 year-old male patient with early onset of knee arthritis and no other symptoms. Ultrasound revealed diffuse and confluent hyperechoic deposits in cartilage, fibrocartilage of the menisci and synovium and calcium pyrophosphate crystals were observed in the synovial fluid of the knee. The concomitant presence of hypomagnesemia, hypocalciuria and hypokalemia made clear the diagnosis of Gitelman’s syndrome associated with chondrocalcinosis.

  3. Computer assisted analysis of sup(99m)Tc pyrophosphate bone uptake in Paget's disease

    International Nuclear Information System (INIS)

    Maayan, M.L.; Eisenberg, J.; Volpert, E.; Shai, F.; Mroczek, R.

    1982-01-01

    The present clinical study describes a method of evaluation of Paget's disease bone by computer assisted analysis of activity curves obtained over normal and pathological portions of the skeleton in the same patient. The data obtained lead to a differential diagnosis between Paget's and metastatic disease of the bone, as well as an evaluation of subsequent therapy. The results indicate a higher bone activity, (expressed by bone flow and bone uptake, of sup(99m)Tc pyrophosphate) in Paget's than in metastatic disease of the bone, as well as a normalization of these parameters after prolonged therapy of Paget's patients with salmon calcitonin

  4. Computer graphic display of cardiac CT scans

    International Nuclear Information System (INIS)

    Palmer, R.; Carlsson, E.

    1982-01-01

    In order to improve spatial conception and quantitative assessment of the cardiac structures based on cardiac computed tomography, methods for computer graphic display were developed. Excised hearts and living dogs with myocardial infarctions were subjected to CT scanning. The data on the scanner tapes were processed to provide isodensity plots, linear section plots, time-weighted integrated isodensity plots as well as topographical density displays and three-dimensional spatial reconstructions of single and multi-layer scans. (orig.)

  5. Relationship between bone uptake of /sup 99m/Tc-pyrophosphate and hydroxyproline in blood and urine

    International Nuclear Information System (INIS)

    Wiegmann, T.; Kirsh, J.; Rosenthall, L.; Kaye, M.

    1976-01-01

    In a group of hospital patients with various diseases, the urinary hydroxyproline-to-creatinine ratio showed a significant correlation (r = 0.63; p is less than 0.001) with the 5-hr bone-to-soft-tissue ratio for /sup 99m/Tc-pyrophosphate uptake. In patients on chronic hemodialysis, a similar correlation was found between the 5-hr bone-to-soft-tissue ratio and hydroxyproline levels in plasma and serum. The findings suggest that /sup 99m/Tc-pyrophosphate binding by bone is related to collagen metabolism

  6. Cooperative scans

    NARCIS (Netherlands)

    M. Zukowski (Marcin); P.A. Boncz (Peter); M.L. Kersten (Martin)

    2004-01-01

    textabstractData mining, information retrieval and other application areas exhibit a query load with multiple concurrent queries touching a large fraction of a relation. This leads to individual query plans based on a table scan or large index scan. The implementation of this access path in most

  7. Use of pyrophosphate-/sup 99m/Tc in diagnosis of malignant tumors of bones

    Energy Technology Data Exchange (ETDEWEB)

    Kasatkin, Yu N; Purizhanskii, I I; Survila, Z P; Agranat, V Z; Korsunskii, V N

    1976-10-01

    Pyrophosphate-/sup 99m/Tc was administered intravenously in a dose of 0.05 to 0.08 mCi per 1 kg body weight of the patient. Studies were made after 4, 6, and 24 hours with fixed and movable detectors. During investigations a gamma-chamber magnetic memory and a 4096-channel analyzer were also used. A quantitative processing of the material was made. The authors determined distribution of the preparation in normal and pathological bone tissue. A total of 142 patients with tumors of the bone tissue were examined; 858 radioisotope measurements were made. An analysis of accumulation of pyrophosphate-/sup 99m/Tc in primary osteogenic tumors in systemic affections of the bones and bone metastases was made. There is a relation between the concentration of the radiopharmaceutical preparation and the morphological structure of the tumor. Reduction in the accumulation of the radioactive indicator took place after radiation and medicinal effect, this made it possible to judge the regression of the tumor.

  8. Diagnostic value of technetium pyrophosphate bone scintigraphy. Study of 277 patients

    International Nuclear Information System (INIS)

    Sainte-Croix, Annick.

    1975-01-01

    277 bone scintigraphs were carried out with 99m technetium pyrophosphate and an attempt was made, on the basis of this experience, to define the advantages and limits of the technique. 99m technetium pyrophosphate seems to be the isotope most suitable for bone scintigraphy. The scintillation camera bone scintigraphic examination is simple, allowing the whole skeleton to be explored in a relatively short time, and above all harmless since the total irradiation to which the organism is exposed throughout is no more than 0.07 rad. The broadest field of application of bone scintigraphy appears to be cancer: in 45 cases out of 66 it revealed bone metastases invisible radiologically and in 28 cases out of 90 the number of metastases observed was greater than that shown by X-rays. In 11 cases however radiologically visible bone metastases were not detected by scintigraphy. In spite of this reservation we consider bone scintigraphy to be a valuable technique, more sensitive than X-ray examinations in the detection of bone metastases of cancers [fr

  9. Radionuclide scanning

    International Nuclear Information System (INIS)

    Shapiro, B.

    1986-01-01

    Radionuclide scanning is the production of images of normal and diseased tissues and organs by means of the gamma-ray emissions from radiopharmaceutical agents having specific distributions in the body. The gamma rays are detected at the body surface by a variety of instruments that convert the invisible rays into visible patterns representing the distribution of the radionuclide in the body. The patterns, or images, obtained can be interpreted to provide or to aid diagnoses, to follow the course of disease, and to monitor the management of various illnesses. Scanning is a sensitive technique, but its specificity may be low when interpreted alone. To be used most successfully, radionuclide scanning must be interpreted in conjunction with other techniques, such as bone radiographs with bone scans, chest radiographs with lung scans, and ultrasonic studies with thyroid scans. Interpretation is also enhanced by providing pertinent clinical information because the distribution of radiopharmaceutical agents can be altered by drugs and by various procedures besides physiologic and pathologic conditions. Discussion of the patient with the radionuclide scanning specialist prior to the study and review of the results with that specialist after the study are beneficial

  10. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    International Nuclear Information System (INIS)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem

    2004-01-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of 201 Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of 201 Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium bicarbonate augmentation may have significant implications for stress-thallium scintigraphy

  11. Sodium bicarbonate-augmented stress thallium myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Sarin, Badal; Chugh, Pradeep Kumar; Kaushal, Dinesh; Soni, Nakse Lal; Sawroop, Kishan; Mondal, Anupam; Bhatnagar, Aseem [Department of Nuclear Medicine, Institute of Nuclear Medicine and Allied Sciences, Brig. S. K. Mazumdar Road, 110054, Delhi (India)

    2004-04-01

    It is well known that sodium bicarbonate in pharmacological doses induces transient alkalosis, causing intracellular transport of serum potassium. The aims of this study were (a) to investigate whether, in humans, myocardial thallium-201 uptake can be augmented by pretreatment with a single bolus of sodium bicarbonate at a pharmacological dose, (b) to verify general safety aspects of the intervention and (c) to evaluate the clinical implications of augmentation of {sup 201}Tl uptake, if any. Routine exercise myocardial scintigraphy was performed twice in eight adult volunteers (five normal and three abnormal), once without intervention and the second time (within a week) following intravenous administration of sodium bicarbonate (88 mEq in 50 ml) as a slow bolus 1 h prior to the injection of {sup 201}Tl. Conventional myocardial thallium study was compared with sodium bicarbonate interventional myocardial scintigraphy with respect to myocardial uptake (counts per minute per mCi injected dose), washout patterns in normal and abnormal myocardial segments, and overall clinical interpretation based on planar and single-photon emission tomographic (SPET) images. All patients remained asymptomatic after the intervention. A mean increase of 53% in myocardial uptake of thallium was noted in post-exercise acquisitions after the intervention, confirming uptake of the tracer via the potassium-hydrogen pump and its augmentation by transient alkalosis. The washout pattern remained unchanged. The visual quality of planar and SPET images improved significantly after the intervention. Out of the five abnormal myocardial segments identified in three cases, four showed significant filling-in after the intervention, causing the diagnosis to be upgraded from ''partial scar'' to ''ischaemia'', or from ''ischaemia'' to ''normal''. The overall scan impression changed in two out of three such cases. Sodium

  12. Myocardial perfusion imaging in hyperthrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Moorin, B.

    1998-01-01

    Full text: Patients with Hyperthrophic Cardiomyopathy (HCM) frequently suffer from syncope and cardiac arrest which may lead to sudden death. This is most often caused by ventricular arrhythmia's in adults, however in young patients the mechanisms are thought to be different. Ischaemia may play a significant role even in young asymptomatic HCM patients. The mechanisms of ischaemic development in HCM differ from those in the 'normal' myocardium (Due to intramural small vessel abnormalities and abnormal myocellular architecture). In HCM the coronary microcirculation is most often affected and massive hypertrophy means more energy is required to promote contraction thus increasing oxygen demand and compounding the effects of any ischaemic changes. A case of a 12 year old HCM patient is presented who has symptoms of syncope associated with exercise whose mother died suddenly of cardiac arrest developed from HCM. A myocardial perfusion rest/stress study was undertaken to detect any underlying myocardial ischaemia. Myocardial perfusion scintigraphy demonstrates any reduction in the microcirculation in addition to that present in the macrocirculation, unlike angiography which will only detect the latter. In this case the scan clearly showed evidence of ischaemia in the lateral wall and this may be an explanation for her episodes of syncope. We suggest an algorithm or the routine work-up of young patients with HCM which makes aggressive use of myocardial perfusion imaging to detect ischaemic changes. This may identify patients who are at higher risk and will assist with treatment decisions. We feel myocardial perfusion scintigraphy is a sensitive non-invasive accurate method of detecting microcirculatory ischaemia and is thus invaluable in HCM patients

  13. Technetium 99m pyrophosphate bone scintigraphy in the exploration of breast cancer bone metastases (analysis of 311 examinations)

    International Nuclear Information System (INIS)

    Bonichon, Francoise.

    1976-01-01

    Sodium pyrophosphate was chosen for its ease of application and the quality of the images it gives. The aim of this study, in the context of breast cancer exploration, is to examine: - its reliability for the detection of bone metastases, - the correlation of its results with other factors. The first part reviews the properties of sup(99m)Tc-labelled sodium pyrophosphate and the current hypotheses on the mechanism of its bone fixation, essential for an understanding of the image formation mechanism and for the interpretation of anomalies. Part two gives an analysis of 311 examinations carried out on 223 patients, obtained by the use of a coded file and modern data processing methods. The following are dealt with in turn: - material and methods, - the results themselves and especially their reliability for the whole skeleton and for one bone at a time, - discussion and comparison with published data. Sup(99m)Tc pyrophosphate bone scintigraphy is a simple examination easy to interpret and allows the whole skeleton to be explored. Abnormal scintigraphic images are: - seldom hypofixing lacunae, - usually 'hyperfixing centres' which point to a perilesional bone reaction and depend on: vascular factors, the affinity of technetium for the immature collagen fibres of the forming bone matrix, the affinity of pyrophosphate for the bone mineral substance [fr

  14. Tumoral calcium pyrophosphate dihydrate deposition disease with bone destruction in the shoulder. CT an MR findings in two cases

    International Nuclear Information System (INIS)

    Mizutani, H.; Ohba, S.; Sasaki, S.; Ando, K.; Mizutani, M.; Matsushita, Y.; Ohtsuka, T.; Terazawa, T.; Ijima, S.

    1998-01-01

    We report on specific CT and MR features in two cases of tumoral calcium pyrophosphate dihydrate deposition disease in the shoulder with unusually large tumors. CT revealed features that were specific to the disease. MR was useful for detecting the extent of the mass and for obtaining information on adjacent soft-tissue and bone-marrow changes. (orig.)

  15. The diagnostic value of Tc-99m PYP, Tl-201 dual isotope SPECT to predict the viability of damaged myocardium in the acute phase of myocardial infarction

    International Nuclear Information System (INIS)

    Matsuo, Hitoshi; Watanabe, Sachiro; Arai, Masazumi

    1991-01-01

    To assess the diagnostic value of Tc-99m pyrophosphate (PYP), Tl-201 dual isotope SPECT for the evaluation of myocardial viability, segmental comparison between dual isotope SPECT and exercise, delayed, and reinjected Tl study were performed with 18 acute myocardial infarction (AMI) patients. Among 72 damaged myocardial segments, 48 segments (67%) were judged as viable by chronic phase Tl studies. The segments with severely reduced Tl uptake by dual SPECT showed significantly lower prevalence of viable myocardium than the segments with reduced and normal Tl uptake (p<0.001). The segments with PYP accumulation localized to the subendocardium represented the favorable outcome compared with the transmural accumulation (p<0.001). And overlap segments show better prognosis than the segments without overlap (p<0.05). Most importantly, we can get better predictive accuracy of myocardial scar by dual isotope SPECT than the judgement by Tl or PYP SPECT alone (83.3% vs 77.8%, 68.1%). Thus, we conclude that Tc-99m PYP, Tl-201 dual isotope SPECT is useful to assess the severity of myocardial damage in the acute phase of myocardial infarction. (author)

  16. Myocardial Hemorrhage After Acute Reperfused ST-Segment–Elevation Myocardial Infarction

    Science.gov (United States)

    Carrick, David; Haig, Caroline; Ahmed, Nadeem; McEntegart, Margaret; Petrie, Mark C.; Eteiba, Hany; Hood, Stuart; Watkins, Stuart; Lindsay, M. Mitchell; Davie, Andrew; Mahrous, Ahmed; Mordi, Ify; Rauhalammi, Samuli; Sattar, Naveed; Welsh, Paul; Radjenovic, Aleksandra; Ford, Ian; Oldroyd, Keith G.

    2016-01-01

    Background— The success of coronary reperfusion therapy in ST-segment–elevation myocardial infarction (MI) is commonly limited by failure to restore microvascular perfusion. Methods and Results— We performed a prospective cohort study in patients with reperfused ST-segment–elevation MI who underwent cardiac magnetic resonance 2 days (n=286) and 6 months (n=228) post MI. A serial imaging time-course study was also performed (n=30 participants; 4 cardiac magnetic resonance scans): 4 to 12 hours, 2 days, 10 days, and 7 months post reperfusion. Myocardial hemorrhage was taken to represent a hypointense infarct core with a T2* value of hemorrhage 2 days post MI was associated with clinical characteristics indicative of MI severity and inflammation. Myocardial hemorrhage was a multivariable associate of adverse remodeling (odds ratio [95% confidence interval]: 2.64 [1.07–6.49]; P=0.035). Ten (4%) patients had a cardiovascular cause of death or experienced a heart failure event post discharge, and myocardial hemorrhage, but not microvascular obstruction, was associated with this composite adverse outcome (hazard ratio, 5.89; 95% confidence interval, 1.25–27.74; P=0.025), including after adjustment for baseline left ventricular end-diastolic volume. In the serial imaging time-course study, myocardial hemorrhage occurred in 7 (23%), 13 (43%), 11 (33%), and 4 (13%) patients 4 to 12 hours, 2 days, 10 days, and 7 months post reperfusion. The amount of hemorrhage (median [interquartile range], 7.0 [4.9–7.5]; % left ventricular mass) peaked on day 2 (Phemorrhage and microvascular obstruction follow distinct time courses post ST-segment–elevation MI. Myocardial hemorrhage was more closely associated with adverse outcomes than microvascular obstruction. Clinical Trial Registration— URL: http://www.clinicaltrials.gov. Unique identifier: NCT02072850. PMID:26763281

  17. Myocardial myoglobin release after acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, P S; Saltissi, S; Coltart, D J; Croft, D N [Saint Thomas' Hospital, London (UK)

    1980-03-01

    The magnitude and time course of myoglobin release from the myocardium following infarction was assessed by radioimmunoassay. The assay showed acceptable precision over a working range from 50 to 750 ng cm/sup -3/, provided careful control of the assay temperature was maintained. The use of this radioimmunoassay as an early diagnostic test for infarction and as a potential measure of the extent of necrosis is considered and comparison made with the release of CK-MB, the myocardial specific isoenzyme of creatine kinase. Of the twenty patients studied with myocardial infarction, all had elevated levels of serum myoglobin including those admitted within 3 hours of the onset of pain. In contrast, CK-MB was not detected in the serum within 5 hours of the onset of pain. Peak serum levels of myoglobin (mean 852 +- 365 ng cm/sup -3/) and CK-MB (mean 71 +- 25 mIU cm/sup -3/) were detected at 8-16 hours and 20-24 hours respectively after the onset of pain. A comparison of peak serum levels of myoglobin and CK-MB showed a good correlation (r = 0.84).

  18. Radiologic features of a pyrophosphate-like arthropathy associated with long-term dialysis

    International Nuclear Information System (INIS)

    Braunstein, E.M.; Martel, W.; Menerey, K.; Fox, I.H.; Swartz, R.

    1987-01-01

    In a series of 28 long-term dialysis patients with musculoskeletal complaints, the radiologic findings in six cases resembled those occurring in the arthropathy of idiopathic calcium pyrophosphate dihydrate deposition (CPPD) disease. These findings included osteophytes, subchondral cysts, and cartilage loss in the metacarpophalangeal joints, patellofemoral joints, wrists, and shoulders. Chondrocalcinosis was present in three of the six cases. There were no significant differences in renal function or levels of serum calcium, phosphorus, iron, ferritin, aluminum, or parathormone between these patients and a control group matched for sex and age. Long-term dialysis may be associated with a metabolic arthritis similar to the arthritis which occurs in CPPD deposition disease. The etiology may include deposition of CPPD crystals, hydroxyapatite, or other calcium-containing substances in joints, or it may be related to a number of dialysis-induced metabolic abnormalities. (orig.)

  19. Pyrophosphate synthesis in iron mineral films and membranes simulating prebiotic submarine hydrothermal precipitates

    Science.gov (United States)

    Barge, Laura M.; Doloboff, Ivria J.; Russell, Michael J.; VanderVelde, David; White, Lauren M.; Stucky, Galen D.; Baum, Marc M.; Zeytounian, John; Kidd, Richard; Kanik, Isik

    2014-03-01

    Cells use three main ways of generating energy currency to drive metabolism: (i) conversion of adenosine diphosphate (ADP) to adenosine triphosphate (ATP) by the proton motive force through the rotor-stator ATP synthase; (ii) the synthesis of inorganic phosphate˜phosphate bonds via proton (or sodium) pyrophosphate synthase; or (iii) substrate-level phosphorylation through the direct donation from an active phosphoryl donor. A mechanism to produce a pyrophosphate bond as “energy currency” in prebiotic systems is one of the most important considerations for origin of life research. Baltscheffsky (1996) suggests that inorganic pyrophosphate (PO74-; PPi) may have preceded ATP/ADP as an energy storage molecule in earliest life, produced by an H+ pyrophosphatase. Here we test the hypothesis that PPi could be synthesized in inorganic precipitates simulating hydrothermal chimney structures transected by thermal and/or ionic gradients. Appreciable yields of PPi were obtained via substrate phosphorylation by acetyl phosphate within the iron sulfide/silicate precipitates at temperatures expected for an alkaline hydrothermal system. The formation of PPi only occurred in the solid phase, i.e. when both Pi and the phosphoryl donor were precipitated with Fe-sulfides or Fe-silicates. The amount of Ac-Pi incorporated into the precipitate was a significant factor in the amount of PPi that could form, and phosphate species were more effectively incorporated into the precipitate at higher temperatures (⩾50 to >85 °C). Thus, we expect that the hydrothermal precipitate would be more enriched in phosphate (and especially, Ac-Pi) near the inner margins of a hydrothermal mound where PPi formation would be at a maximum. Iron sulfide and iron silicate precipitates effectively stabilized Ac-Pi and PPi against hydrolysis (relative to hydrolysis in aqueous solution). Thus it is plausible that PPi could accumulate as an energy currency up to useful concentrations for early life in a

  20. Radiologic features of a pyrophosphate-like arthropathy associated with long-term dialysis

    Energy Technology Data Exchange (ETDEWEB)

    Braunstein, E.M.; Martel, W.; Menerey, K.; Fox, I.H.; Swartz, R.

    1987-08-01

    In a series of 28 long-term dialysis patients with musculoskeletal complaints, the radiologic findings in six cases resembled those occurring in the arthropathy of idiopathic calcium pyrophosphate dihydrate deposition (CPPD) disease. These findings included osteophytes, subchondral cysts, and cartilage loss in the metacarpophalangeal joints, patellofemoral joints, wrists, and shoulders. Chondrocalcinosis was present in three of the six cases. There were no significant differences in renal function or levels of serum calcium, phosphorus, iron, ferritin, aluminum, or parathormone between these patients and a control group matched for sex and age. Long-term dialysis may be associated with a metabolic arthritis similar to the arthritis which occurs in CPPD deposition disease. The etiology may include deposition of CPPD crystals, hydroxyapatite, or other calcium-containing substances in joints, or it may be related to a number of dialysis-induced metabolic abnormalities.

  1. Study of irradiated bone: Part III. /sup 99m/Tc pyrophosphate autoradiographic changes

    International Nuclear Information System (INIS)

    King, M.A.; Corriveau, O.; Casarett, G.W.; Weber, D.A.

    1978-01-01

    The macroautoradiographic and microautoradiographic localization of /sup 99m/Tc-pyrophosphate (/sup 99m/TcPPi) was studied in x-irradiated bone of rabbits up to one year post-irradiation. In cortical bone, /sup 99m/TcPPi was concentrated on bone surfaces near vasculature. Both forming and resorbing bone surfaces were comparably labeled at 2 hrs post-injection. Uptake on the surface of sites of haversian bone remodeling was observed to be at least part of the increased /sup 99m/TcPPi observed in irradiated bone in camera images. In irradiated trabecular bone 12 months following irradiation, a patchy decrease in /sup 99m/TcPPi uptake was correlated with localized decreases in vasculature

  2. The effect of preparation method on the proton conductivity of indium doped tin pyrophosphates

    DEFF Research Database (Denmark)

    Anfimova, Tatiana; Lie-Andersen, T.; Jensen, E. Pristed

    2015-01-01

    Indium doped tin pyrophosphates were prepared by three synthetic routes. A heterogeneous synthesis from metal oxides with excess phosphoric acid produces crystalline phosphate particles with a phosphorus rich amorphous phase along the grain boundaries. The amorphous phase prevents the agglomeration...... decrease in conductivity as well as significant agglomeration of the particles, as evident in TEM and from particle size distribution measurements. Homogeneous synthesis with soluble metal acetates or chlorides as precursors results in a single crystalline phase with a small particle size, but strongly...... agglomerated, and a low conductivity at 10- 7-10- 6 Scm- 1 level. Further impregnation of the agglomerates with phosphoric acid does not lead to formation of the phosphorus rich amorphous layers on the surface of the crystals. An intermediate conductivity of 10- 3 Scm- 1 was observed for the acid treated...

  3. Identification of monoclinic calcium pyrophosphate dihydrate and hydroxyapatite in human sclera using Raman microspectroscopy.

    Science.gov (United States)

    Chen, Ko-Hua; Li, Mei-Jane; Cheng, Wen-Ting; Balic-Zunic, Tonci; Lin, Shan-Yang

    2009-02-01

    Raman microspectroscopy was first used to determine the composition of a calcified plaque located at the pterygium-excision site of a 51-year-old female patient's left nasal sclera after surgery. It was unexpectedly found that the Raman spectrum of the calcified sample at 1149, 1108, 1049, 756, 517, 376 and 352/cm was similar to the Raman spectrum of monoclinic form of calcium pyrophosphate dihydrate (CPPD) crystal, but differed from the Raman spectrum of triclinic form of CPPD. An additional peak at 958/cm was also observed in the Raman spectrum of the calcified plaque, which was identical to the characteristic peak at 958/cm of hydroxyapatite (HA). This is the first study to report the spectral biodiagnosis of both monoclinic CPPD and HA co-deposited in the calcified plaque of a patient with sclera dystrophic calcification using Raman microspectroscopy.

  4. Study of thallium scintigraphy for myocardial infarction performed within 72 hours of attack

    Energy Technology Data Exchange (ETDEWEB)

    Setsuda, Koichi; Tomita, Yoshifumi; Takayama, Morimasa (Nippon Medical School, Tokyo)

    1983-11-01

    In 40 cases undergoing /sup 201/Tl myocardial scanning within 72 hours of attack of myocardial infarction, a significant correlation was found between the infarct size determined by myocardial scanning and the size of the infarction estimated on the basis of ECG findings and serum enzymes. The group with high pulmonary capillary wedge pressure was the group with low Tl scores. The group showing dyskinesis and aneurysm in left ventriculography showed low Tl scores and a significant correlation between the ejection fraction calculated from left ventriculograms and the Tl score. The above date indicate that /sup 201/Tl myocardial scanning in the acute phase after attack of infarction reflects the infarction size and cardiac function.

  5. Partial oxidation of D-xylose to maleic anhydride and acrylic acid over vanadyl pyrophosphate

    International Nuclear Information System (INIS)

    Ghaznavi, Touraj; Neagoe, Cristian; Patience, Gregory S.

    2014-01-01

    Xylose is the second most abundant sugar after glucose. Despite its tremendous potential to serve as a renewable feedstock, few commercial processes exploit this resource. Here, we report a new technology in which a two-fluid nozzle atomizes a xylose-water solution into a capillary fluidized bed operating above 300 °C. Xylose-water droplets form at the tip of the injector, vaporize then react with a heterogeneous mixed oxide catalyst. A syringe pump metered the solution to the reactor charged with 1 g of catalyst. Product yield over vanadyl pyrophosphate was higher compared to molybdenum trioxide-cobalt oxide and iron molybdate; it reached 25% for maleic anhydride, 17% for acrylic acid and 11% for acrolein. Gas residence time was 0.2 s. The catalyst was free of coke even after operating for 4 h – based on a thermogravimetric analysis of catalyst withdrawn from the reactor. Below 300 °C, powder agglomerated at the tip of the injector at 300 °C; it also agglomerated with a xylose mass fraction of 7% in water. - Highlights: • D-xylose reacts to form maleic anhydride and acrylic acid above 250 °C. • Vanadyl pyrophosphate is both active and selective for maleic and acrylic acid. • Acid and acrolein yield approaches 50% for a xylose mass fraction of 3% in water. • Catalyst agglomerates at low temperatures and high xylose aqueous mass fraction. • Atomization quality is a determining factor to minimize agglomeration

  6. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits

    International Nuclear Information System (INIS)

    Kowalsky, R.J.; Dalton, D.R.

    1981-01-01

    The amount of tin(II) required for adequate reduction, complexation, and stability of technetium Tc 99m pertechnetate in radiopharmaceutical kits, and methods of preventing the loss of tin(II) during formulation of these lyophilized kits are investigated. Tin(II) loss from stannous chloride solutions was studied under several conditions, including room air versus nitrogen atmospheres, during vial filling in a laminar-flow hood with samples frozen on dry ice versus samples at room temperature, during lyophilization, and during storage under refrigerated, ambient, and elevated temperatures. Various amounts of stannous chloride, ranging from 5 to 1000 microgram/ml, were used in formulating sodium pertechnetate Tc 99m kits containing 100 mCi technetium Tc 99m and 0.4 microgram total technetium. Samples were removed at various times; hydrolyzed technetium, pertechnetate, and technetium Tc 99m pyrophosphate were isolated on instant thin-layer chromatography-silica gel and quantified with a scintillation counter. The time necessary to deoxygenate distilled water by nitrogen purging was measured. Several sources of stannous chloride were assayed for tin(II) content. Tin(II) loss occurs rapidly in solution (15% in one hour) unless continuously protected with nitrogen, and during vial filling in a laminar-flow hood unless frozen with dry ice. No substantial loss of tin(II) was detected during lyophilization or during storage of lyophilized product at any of the three temperatures. A minimum of 400 microgram tin(II) was required to provide 90% technetium Tc 99m pyrophosphate at six hours after preparation. Adequate deoxygenation of small quantities (450 ml) of water was accomplished in less than one hour. Some stannous chloride salts were highly oxidized in the dry state, and only high-purity elemental tin wire gave acceptable yields of tin

  7. Crystallographic and thermodynamic characterization of phenylaminopyridine bisphosphonates binding to human farnesyl pyrophosphate synthase.

    Directory of Open Access Journals (Sweden)

    Jaeok Park

    Full Text Available Human farnesyl pyrophosphate synthase (hFPPS catalyzes the production of the 15-carbon isoprenoid farnesyl pyrophosphate. The enzyme is a key regulator of the mevalonate pathway and a well-established drug target. Notably, it was elucidated as the molecular target of nitrogen-containing bisphosphonates, a class of drugs that have been widely successful against bone resorption disorders. More recently, research has focused on the anticancer effects of these inhibitors. In order to achieve increased non-skeletal tissue exposure, we created phenylaminopyridine bisphosphonates (PNP-BPs that have bulky hydrophobic side chains through a structure-based approach. Some of these compounds have proven to be more potent than the current clinical drugs in a number of antiproliferation assays using multiple myeloma cell lines. In the present work, we characterized the binding of our most potent PNP-BPs to the target enzyme, hFPPS. Co-crystal structures demonstrate that the molecular interactions designed to elicit tighter binding are indeed established. We carried out thermodynamic studies as well; the newly introduced protein-ligand interactions are clearly reflected in the enthalpy of binding measured, which is more favorable for the new PNP-BPs than for the lead compound. These studies also indicate that the affinity of the PNP-BPs to hFPPS is comparable to that of the current drug risedronate. Risedronate forms additional polar interactions via its hydroxyl functional group and thus exhibits more favorable binding enthalpy; however, the entropy of binding is more favorable for the PNP-BPs, owing to the greater desolvation effects resulting from their large hydrophobic side chains. These results therefore confirm the overall validity of our drug design strategy. With a distinctly different molecular scaffold, the PNP-BPs described in this report represent an interesting new group of future drug candidates. Further investigation should follow to

  8. Scanning table

    CERN Multimedia

    1960-01-01

    Before the invention of wire chambers, particles tracks were analysed on scanning tables like this one. Today, the process is electronic and much faster. Bubble chamber film - currently available - (links can be found below) was used for this analysis of the particle tracks.

  9. Scan Statistics

    CERN Document Server

    Glaz, Joseph

    2009-01-01

    Suitable for graduate students and researchers in applied probability and statistics, as well as for scientists in biology, computer science, pharmaceutical science and medicine, this title brings together a collection of chapters illustrating the depth and diversity of theory, methods and applications in the area of scan statistics.

  10. Myocardial perfusion SPECT imaging in patients with myocardial bridging

    International Nuclear Information System (INIS)

    Fang Wei; Qiu Hong; Yang Weixian; Wang Feng; He Zuoxiang

    2008-01-01

    Objective: Stress myocardial perfusion SPECT imaging was used to assess myocardial ischemia in patients with myocardial bridging. Methods: Ninety-six patients with myocardial bridging of the left anterior descending artery documented by coronary angiography were included in this study. All under- went exercise or pharmacological stress myocardial perfusion SPECT assessing myocardial ischemia. None had prior myocardial infarction. One year follow-up by telephone interview was performed in all patients. Results The mean stenotic severity of systolic phase on angiography was (65 ± 19)%. In the SPECT study, 20 of 96 (20.8%) patients showed abnormal perfusion. This percentage was significantly higher than that of stress electrocardiogram (ECG). The higher positive rate of SPECT perfusion images was showed in the group of patients with severe systolic narrowing (≥75%) than that with mild-to-moderate systolic narrowing (50% vs 6.3%, P<0.001). The prevalence of abnormal image was significantly higher in ELDERLY PEOPLE; patients with STT change on rest ECG than in those with normal rest ECG (54.2% vs 9.7%, P<0.001). During follow-up, one patient with abnormal SPECT perfusion image sustained angina and accepted percutaneous coronary intervention, and no cardiac event occurred in patients with normal images. Conclusions: Stress myocardial perfusion SPECT imaging can be used effectively for assessing myocardial ischemia and has potential prognostic value for patients with myocardial bridging. (authors)

  11. Ischemic preconditioning effect of prodromal angina is attenuated in acute myocardial infarction patients with hypertensive left ventricular hypertrophy

    International Nuclear Information System (INIS)

    Takeuchi, Toshiharu; Kikuchi, Kenjiro; Hasebe, Naoyuki; Ishii, Yoshinao

    2011-01-01

    Several animal experiments on acute myocardial infarction (AMI) have shown that the cardioprotective effects of ischemic preconditioning are more significant in hypertensive subjects. However, because there are no clinical data on the impact of hypertension on ischemic preconditioning in patients with AMI, whether clinical ischemic preconditioning of prodromal angina was beneficial in AMI patients with hypertension was investigated in the present study. 125 patients with a first anterior AMI who had undergone successful reperfusion therapy were divided into 2 groups, with or without hypertension, and into 2 further subgroups based on the presence or absence of prodromal angina. Dual-isotope (thallium-201(TL)/Tc-99m pyrophosphate) single-photon emission computed tomography (SPECT) was performed within 1 week of reperfusion therapy. Left ventricular (LV) function and LV mass index (LVMI) were measured by left ventriculography and echocardiography, respectively. In patients without hypertension, prodromal angina resulted in significantly less myocardial damage on TL-SPECT, better LV ejection fraction and a greater myocardial blush grade compared to patients without prodromal angina. However, these cardioprotective effects of prodromal angina were significantly diminished in hypertensive patients. Importantly, the myocardial salvage effects of prodromal angina showed a significant negative correlation with LVMI, which was significantly greater in hypertensive patients. The cardioprotective effects of prodromal angina were attenuated in patients with hypertension. Hypertensive LV hypertrophy may crucially limit the effects of ischemic preconditioning in AMI. (author)

  12. Tomoscintigraphic assessment of myocardial metabolic heterogenity

    International Nuclear Information System (INIS)

    Roesler, H.; Hess, T.; Weiss, M.; Noelpp, U.; Mueller, G.; Hoeflin, F.; Kinser, J.

    1983-01-01

    I-123-omega-heptadecanoic acid (HDA) was evaluated for myocardial scanning in 59 healthy volunteers and 133 patients, using a 7-pinhole collimator. Early (uptake) and late (retention) images were compared visually. Regional HDA elimination was also followed semiquantitatively based on the calculation of a retention-over-uptake ratio, R(phi), derived from the maximal counts/pixel in 60 midventricular slice sectors. The healthy heart concentrated HDA homogeneously in all segments with no difference between early and late images. The minimal R(phi), taken as representative of that myocardium with the best function, was unchanged after maximal ergometer stress and with dipyramidole-induced hyperperfusion. A circumscribed decreased HDA uptake is the clear-cut criterion for an abnormal finding. HDA tomography of the myocardium had an 86% sensitivity for myocardial infarcts (MIs) up to 4 wk old, and 83% for myocardial scars (MSs). Comparing early and late tomograms, we find a cool-warm sequence more often with acute and subacute MIs. A cool-cool or a cold-cold sequence dominated with MSs. HDA tomoscintigraphy cannot replace TI-201 for the evaluation of regional coronary reserve in coronary heart disease

  13. Biosynthesis of (+)-cis- and (+)-trans-sabinene hydrate from geranyl pyrophosphate by a soluble enzyme system from sweet marjoram (Majorana hortensis)

    International Nuclear Information System (INIS)

    Hallahan, T.W.

    1988-01-01

    A soluble enzyme preparation from the leaves of sweet marjoram (Majorana hortensis Moench) catalyzes the divalent cation-dependent cyclization of [1- 3 H]geranyl pyrophosphate to the bicyclic monoterpene alcohols (+)-cis- and (+)-trans-[6 3 H]sabinene hydrate, providing labeling patterns consistent with current mechanistic considerations. The two enzymatic activities were inseparable by several chromatographic procedures, and differential inactivation studies suggesting that the two activities reside with the same enzyme. The enzymatic cyclization is considered to proceed by the initial ionization and isomerization of geranyl pyrophosphate to (-)-(3R)-linalyl pyrophosphate and the subsequent cyclization of this enzyme bound tertiary allylic intermediate to the monocyclic (+)-(4R)-α-terpinyl cation. A 1,2-hydride shift and a second cyclization with water capture of the resulting cation completes the reaction sequence. No free intermediates were detectable in the conversion of geranyl pyrophosphate to the sabinene hydrates as determined by isotopic dilution experiments

  14. Influence of synthesis conditions on physicochemical parameters and corrosion inhibiting activity of strontium pyrophosphates SrMIIP2O7 (MII = Mg and Zn).

    Czech Academy of Sciences Publication Activity Database

    Gorodylova, N.; Dohnalová, Ž.; Šulcová, P.; Bělina, P.; Vlček, Milan

    2016-01-01

    Roč. 93, 1 April 2016 (2016), s. 77-86 ISSN 0300-9440 Institutional support: RVO:61389013 Keywords : anticorrosive properties * paint coating * pyrophosphate Subject RIV: CA - Inorganic Chemistry Impact factor: 2.858, year: 2016

  15. Pseudo-dissection of ascending aorta in inferior myocardial infarction.

    Directory of Open Access Journals (Sweden)

    Grahame K. Goode

    2011-06-01

    Full Text Available Acute aortic dissection is a cardiac emergency which can present as inferior myocardial infarction. It has high morbidity and mortality requiring prompt diagnosis and treatment. Rapid advances in noninvasive imaging modalities have facilitated the early diagnosis of this condition and in ruling out this potentially catastrophic illness. We report an interesting case of a 57 year- old -man who presented with inferior myocardial infarction requiring thrombolysis and temporary pacing wire for complete heart block. An echocardiogram was highly suspicious of aortic dissection. CT scan confirmed that the malposition of the temporary pacing wire through the aorta mimicked aortic dissection.

  16. Scanning holograms

    International Nuclear Information System (INIS)

    Natali, S.

    1984-01-01

    This chapter reports on the scanning of 1000 holograms taken in HOBC at CERN. Each hologram is triggered by an interaction in the chamber, the primary particles being pions at 340 GeV/c. The aim of the experiment is the study of charm production. The holograms, recorded on 50 mm film with the ''in line'' technique, can be analyzed by shining a parallel expanded laser beam through the film, obtaining immediately above it the real image of the chamber which can then be scanned and measured with a technique half way between emulsions and bubble chambers. The results indicate that holograms can be analyzed as quickly and reliably as in other visual techniques and that to them is open the same order of magnitude of large scale experiments

  17. Bone scans

    International Nuclear Information System (INIS)

    Hetherington, V.J.

    1989-01-01

    Oftentimes, in managing podiatric complaints, clinical and conventional radiographic techniques are insufficient in determining a patient's problem. This is especially true in the early stages of bone infection. Bone scanning or imaging can provide additional information in the diagnosis of the disorder. However, bone scans are not specific and must be correlated with clinical, radiographic, and laboratory evaluation. In other words, bone scanning does not provide the diagnosis but is an important bit of information aiding in the process of diagnosis. The more useful radionuclides in skeletal imaging are technetium phosphate complexes and gallium citrate. These compounds are administered intravenously and are detected at specific time intervals postinjection by a rectilinear scanner with minification is used and the entire skeleton can be imaged from head to toe. Minification allows visualization of the entire skeleton in a single image. A gamma camera can concentrate on an isolated area. However, it requires multiple views to complete the whole skeletal image. Recent advances have allowed computer augmentation of the data received from radionucleotide imaging. The purpose of this chapter is to present the current radionuclides clinically useful in podiatric patients

  18. Acute myocardial infarction

    International Nuclear Information System (INIS)

    RISCHPLER, Christoph

    2016-01-01

    Inflammatory processes after myocardial infarction have gained major interest in recent cardiovascular research. It is believed that not only the degree of cell recruitment to the heart plays a pivotal role in the quality of wound healing after myocardial infarction, but also the balance between different types or even subtypes of cells. It is also this balance which is thought to control key processes in tissue repair, such as apoptosis and neoangiogenesis. In this paper, we aim to review imaging strategies (with a special focus on nuclear molecular imaging strategies) that target cells and processes involved in postischemic inflammation and that have a high potential to be translated into clinic or that are already being used and evaluated in humans.

  19. Thallium-201 myocardial imaging

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.

    1980-01-01

    Three views are routinely obtained for 201 Tl scintigraphy: 0 0 anterior, 45 0 left-anterior-oblique, both views with the patient supine and a left-lateral view, with the patient lying on his right side. Following intravenous injection of 201 Tl, the scintiscans of a normal subject only demonstrate the left ventricle. In patients with normal myocardial perfusion, the left ventricle appears horseshoe or ovoid in shape. The central area of decreased activity represents the left ventricular cavity and is normal. The accumulation of 201 Tl in the normal left ventricle is usually homogeneous. However, some areas with apparent diminished uptake may occur in the normal subject. These variations of the normal image are discussed. The right ventricle, because of its smaller myocardial mass and relatively less 201 Tl accumulation per gram of tissue, is usually on a resting study not, or only faintly, visualized. However, following exercise, the right ventricle is clearly visualized. (Auth.)

  20. Myocardial ischemia in hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Lima Filho, Moyses de Oliveira; Figueiredo, Geraldo L.; Simoes, Marcus V.; Pyntia, Antonio O.; Marin Neto, Jose Antonio

    2000-01-01

    Myocardial ischemia in hypertrophic cardiomyopathy is multifactorial and explains the occurrence of angina, in about 50% of patients. The pathophysiology of myocardial ischemia may be explained by the increase of the ventricular mass and relative paucity of the coronary microcirculation; the elevated ventricular filling pressures and myocardial stiffness causing a compression of the coronary microvessels; the impaired coronary vasodilator flow reserve caused by anatomic and functional abnormalities; and the systolic compression of epicardial vessel (myocardial bridges). Myocardial ischemia must be investigated by perfusion scintigraphic methods since its presence influences the prognosis and has relevant clinical implications for management of patients. Patients with hypertrophic cardiomyopathy and documented myocardial ischemia usually need to undergo invasive coronary angiography to exclude the presence of concomitant atherosclerotic coronary disease. (author)

  1. Acute myocardial infarcts

    International Nuclear Information System (INIS)

    Just, H.

    1988-01-01

    Acute myocardial infarction is a major complication of stenosing coronary artery disease and constitutes the most frequent single cause of death. It is caused by thrombotic occlusion of one of the major epicardial coronary arterial branches in most cases. Sudden death due to ventricular fibrillation is responsible for the majority of early fatalities. In 60% of all fatal infarcts, death occurs within 1 h of the onset of pain. The final extension of myocardial necrosis is reached within 2-4 h. An integrated programme has therefore been developed for the supervision and treatment of patients suffering acute coronary attack; it has been shown that it can markedly lower infarct mortality. It includes mobile prehospital care, intensive care treatment in the hospital, and rehabilitative procedures for application during reconvalescence. Early antiarrhythmic treatment and myocardial reperfusion via fibrinolysis are the main therapeutic procedures in the earliest stage. In hospital an operating room and an operating team must be available round the clock for the performance of coronary angiography followed by percutaneous transluminal coronary angioplasty or bypass surgery, which can be safely carried out in the acute stage provided the indications are strictly observed. Mortality and morbidity can be significantly lowered and both life expectancy and quality of life can be remarkably improved. (orig.) [de

  2. Three-dimensional structure of phosphoribosyl pyrophosphate synthetase from E. coli at 2.71 Å resolution

    Energy Technology Data Exchange (ETDEWEB)

    Timofeev, V. I., E-mail: inna@ns.crys.ras.ru, E-mail: tostars@mail.ru, E-mail: ugama@yandex.ru [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Abramchik, Yu. A. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Zhukhlistova, N. E. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation); Muravieva, T. I.; Esipov, R. S. [Russian Academy of Sciences, Shemyakin–Ovchinnikov Institute of Bioorganic Chemistry (Russian Federation); Kuranova, I. P. [Russian Academy of Sciences, Shubnikov Institute of Crystallography (Russian Federation)

    2016-01-15

    Phosphoribosyl pyrophosphate synthetase from Escherichia coli was cloned, purified, and crystallized. Single crystals of the enzyme were grown under microgravity. The X-ray diffraction data set was collected at the Spring-8 synchrotron facility and used to determine the three-dimensional structure of the enzyme by the molecular-replacement method at 2.71 Å resolution. The active and regulatory sites in the molecule of E. coli phosphoribosyl pyrophosphate synthetase were revealed by comparison with the homologous protein from Bacillus subtilis, the structure of which was determined in a complex with functional ligands. The conformations of polypeptide-chain fragments surrounding and composing the active and regulatory sites were shown to be identical in both proteins.

  3. Determination of the vitality of the femoral head with sup(99m)Tc-Sn-pyrophosphate scintigraphy

    International Nuclear Information System (INIS)

    Greiff, J.

    1980-01-01

    A series of 14 patients who for various reasons were scheduled for total hip replacement were investigated. sup(99m)Tc-Sn-pyrophosphate scintigraphy and tetracycline labelling of the bone structure was performed prior to surgery, and subsequently the femoral heads were submitted to histological evaluation on decalcified as well as non-decalcified slides. The evaluation of the scintigraphs was performed by a specialist in nuclear medicine and the histological slides were evaluated by a pathologist, in the both cases without the radiological findings or the clinical history. The scintigraphic evaluations of the vitality of the femoral head were in all cases verified by the histological examination, whereas the radiological findings in three cases failed to demonstrate that a femoral head necrosis actually was present. From this study it can be concluded that sup(99m)Tc-Sn-pyrophosphate scintigraphy is an excellent method of assessing bone vitality in the femoral head. (author)

  4. Thermal lens study of thermo-optical properties and concentration quenching of Er3+-doped lead pyrophosphate based glasses

    Energy Technology Data Exchange (ETDEWEB)

    Santos, C. C. [Universidade Federal do Ceara, Ceara, Brazil; Rocha, U. [Grupo de Fotônica e Fluidos Complexos, Instituto de Física, Brazil; Guedes, Ilde [Universidade Federal do Ceara, Ceara, Brazil; Vermelho, M. V. D. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil; Boatner, Lynn A [ORNL; Jacinto, C. [Instituto de Fisica, Universidade Federal de Alagoas, Brazil

    2012-01-01

    In this work, we have used the thermal lens technique combined with conventional spectroscopy to characterize the thermo-optical properties of Er3+-doped lead pyrophosphate-based glasses. More precisely, we have investigated and quantified experimentally the fluorescence quantum efficiencies of the Er3+ levels, and we describe the role of concentration quenching effects. The fluorescence quantum efficiency of the 4I13/2 level is very high when compared to other phosphate glasses, while that of the green-coupled levels is very small. Other important photonic materials parameters, such as the thermal diffusivity and temperature coefficient of the optical path length change, were obtained and compared with those of other glass systems. The cumulative results obtained here for the Er-doped lead pyrophosphate glass show that this material is a good candidate for photonic applications with a characteristic Er3+ infrared emission around 1550 nm.

  5. Improved performance of Nb-doped vanadyl pyrophosphate, catalyst for n-butane oxidation to maleic anhydride

    Energy Technology Data Exchange (ETDEWEB)

    Pavarelli, G.; Caldarelli, A.; Cavani, F. [Bologna Univ. (Italy). Dipt. di Chimica Industriale ' Toso Montanari' ; Cortelli, C.; Luciani, S. [Polynt SpA, Scanzorosciate (Italy)

    2013-11-01

    We report here about an investigation on the role of Nb{sup 5+} when used as a promoter for vanadyl pyrophosphate, catalyst for the oxidation of n-butane to maleic anhydride. The effect of Nb was very complex, a function of both its amount and the reaction temperature used. The optimal catalytic behavior was shown for very low Nb contents, i.e., for a V/Nb atomic ratio as low as 150. The main role of Nb was that of accelerating the formation of a limited amount of {gamma}-VOPO{sub 4} on the surface of vanadyl pyrophosphate, by accelerating the oxidation of V{sup 4+} into V{sup 5+} under reaction conditions. (orig.)

  6. A new application of stannic pyrophosphate in nuclear medicine: scintigraphy of choroid plexus, morphological and quantitative study

    International Nuclear Information System (INIS)

    Tovar, G. de; Akerman, M.; Panneciere, C.; Perez, R.

    1975-01-01

    It was shown that the concentration of pertechnetate (Tc 99m) in the choroid plexus can be increased by previous injection of stannic pyrophosphate. This phenomenon affords an excellent morphological study of these structures, which trace most of the cerebral ventricles. An isotopic ventricle scintigraph is thus obtained by simple intraveinous injection. Furthermore a dynamic study supplies information on the functional activity of choroid plexus, of special interest in research on the pathology of the cerebrospinal fluid [fr

  7. 5 years prognostic value of dipyridamole-thallium myocardial imaging

    International Nuclear Information System (INIS)

    Yang Yifeng; Qian Zhonghao; Jiang Changying

    1993-01-01

    A prognostic study of dipyridamole-thallium myocardial imaging was conducted with the use of logistic regression. Over a 5 years follow-up period, cardiac events occurred in 13 patients within the 41 patients tested, death in 5 and myocardial infarction in 8. The results of this study indicates that dipyridamole-thallium imaging has significant prognostic utility and that an abnormal scan increased the relative risk for the development of subsequent myocardial infarction or cardiac death (O.R. 18.54). The presence of transient multiple thallium defects further increased the risk of a cardiac event. In conclusion , intravenous dipyridamole thallium imaging is a potentially useful diagnostic test to determine the presence and severity of coronary diseases, and this noninvasive method is also beneficial for prognosis

  8. Extraction of left ventricular myocardial mass from dynamic 11C-acetate PET

    DEFF Research Database (Denmark)

    Harms, Hans; Tolbod, Lars Poulsen; Hansson, Nils Henrik

    Background: Dynamic 11C-acetate PET is used to quantify oxygen metabolism, which is used to calculate left ventricular (LV) myocardial efficiency, an early marker of heart failure. This requires estimation of LV myocardial mass and is typically derived from a separate cardiovascular magnetic...... resonance (CMR) scan. The aim of this study was to explore the feasibility of estimating myocardial mass directly from a dynamic 11C-acetate PET scan. Methods: 21 subjects underwent a 27-min 11C-acetate PET scan on a Siemens Biograph TruePoint 64 PET/CT scanner. In addition, 10 subjects underwent a dynamic...... 11C-acetate 27-min PET scan on a GE Discovery ST PET/CT scanner. Parametric images of uptake rate K1 and both arterial (VA) and venous (VV) spillover fractions were generated using a basis function implementation of the standard single tissue compartment model using non-gated dynamic data. The LV...

  9. The characteristics of pyrophosphate: D-fructose-6-phosphate 1-phosphotransferases from Sansevieria trifasciata leaves and Phaseolus coccineus stems.

    Science.gov (United States)

    Kowalczyk, S

    1987-01-01

    Three different molecular forms of pyrophosphate-dependent phosphofructokinase have been isolated: one from Sansevieria trifasciata leaves and two from Phaseolus coccineus stems. The form isolated from S. trifasciata has the molecular weight of about 115,000. The apparent molecular weights for the two forms from mung bean were approximately 220,000 and 450,000. All three forms have the same pH optima, an absolute requirement for Mg2+ ions both in the forward and reverse reaction, but differ in their sensitivity toward fructose 2,6-bisphosphate. Kinetic properties of the partially purified enzymes have been investigated in the presence and absence of fructose 2,6-bisphosphate. Pyrophosphate-dependent phosphofructokinase from S. trifasciata exhibited hyperbolic kinetics with all substrates tested. The saturation curves of the enzyme (form A) from mung bean for pyrophosphate, fructose 6-phosphate and fructose 1,6-bisphosphate were sigmoidal in the absence of fructose 2,6-bisphosphate. In the presence of fructose 2,6-bisphosphate these kinetics became hyperbolic.

  10. Cofortification of ferric pyrophosphate and citric acid/trisodium citrate into extruded rice grains doubles iron bioavailability through in situ generation of soluble ferric pyrophosphate citrate complexes.

    Science.gov (United States)

    Hackl, Laura; Cercamondi, Colin I; Zeder, Christophe; Wild, Daniela; Adelmann, Horst; Zimmermann, Michael B; Moretti, Diego

    2016-05-01

    Iron fortification of rice is a promising strategy for improving iron nutrition. However, it is technically challenging because rice is consumed as intact grains, and ferric pyrophosphate (FePP), which is usually used for rice fortification, has low bioavailability. We investigated whether the addition of a citric acid/trisodium citrate (CA/TSC) mixture before extrusion increases iron absorption in humans from FePP-fortified extruded rice grains. We conducted an iron absorption study in iron-sufficient young women (n = 20), in which each participant consumed 4 different meals (4 mg Fe/meal): 1) extruded FePP-fortified rice (No CA/TSC); 2) extruded FePP-fortified rice with CA/TSC added before extrusion (CA/TSC extruded); 3) extruded FePP-fortified rice with CA/TSC solution added after cooking and before consumption (CA/TSC solution); and 4) nonextruded rice fortified with a FeSO4 solution added after cooking and before consumption (reference). Iron absorption was calculated from erythrocyte incorporation of stable iron isotopes 14 d after administration. In in vitro experiments, we assessed the soluble and dialyzable iron from rice meals in which CA/TSC was added at different preparation stages and from meals with different iron:CA:TSC ratios. Fractional iron absorption was significantly higher from CA/TSC-extruded meals (3.2%) than from No CA/TSC (1.7%) and CA/TSC solution (1.7%; all P solubility and dialyzability were higher in CA/TSC-extruded rice than in rice with No CA/TSC and CA/TSC solution, and solubility increased with higher amounts of added CA and TSC in extruded rice. Iron bioavailability nearly doubled when CA/TSC was extruded with FePP into fortified rice, resulting in iron bioavailability comparable to that of FeSO4 We attribute this effect to an in situ generation of soluble FePP citrate moieties during extrusion and/or cooking because of the close physical proximity of FePP and CA/TSC in the extruded rice matrix. This trial was registered at

  11. Role of myocardial perfusion SPECT in asymptomatic diabetic patients

    International Nuclear Information System (INIS)

    Cho, I.; Chun, K.; Won, K.; Lee, H.; Park, J.; Shin, D.; Kim, Y.; Shim, B.; Lee, J.

    2002-01-01

    Purpose: It is important that early diagnosis and treatment of coronary artery disease in diabetic patients, but there are few reports on the prevalence of stress-induced myocardial perfusion abnormalities and the rates of cardiac event in patients with type 2 diabetes. We evaluated the scan findings on gated myocardial perfusion SPECT in asymptomatic diabetic patients. Methods: We performed pharmacological stress test and gated perfusion SPECT in 69 diabetic patients without cardiovascular symptom (mean age: 65 year, male 31 and female 38). Patients underwent two-day imaging protocol and stress study was performed injection of Tc-99m MIBI during adenosine infusion. We followed up these patients by reviewing medical records. Results: Fifty-two of 69 patients (74.5%) showed normal scan findings and 17 patients (24.6%) showed reversible or fixed perfusion defects. Three of 52 patients with normal scan findings showed decreased LV ejection fraction and decreased wall motion. Twenty-three patients with normal scan findings were possible to follow up for more than 1yr (mean time: 18.3±3.3 mo.) and they all had no cardiac event. Three patients with reversible perfusion defects were performed coronary angioplasty. Conclusion: Myocardial perfusion SPECT is a noninvasive method and maybe useful in early diagnosis and predicting prognosis in diabetic patients

  12. Structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate and two molecules of inorganic phosphate

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jaeok [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); Lin, Yih-Shyan [McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); Tsantrizos, Youla S. [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 801 Rue Sherbrooke Ouest, Montreal, QC H3A 0B8 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); Berghuis, Albert M., E-mail: albert.berghuis@mcgill.ca [McGill University, 3655 Promenade Sir William Osler, Montreal, QC H3G 1Y6 (Canada); McGill University, 3649 Promenade Sir William Osler, Montreal, QC H3G 0B1 (Canada); McGill University, 3775 Rue University, Montreal, QC H3A 2B4 (Canada)

    2014-02-19

    A co-crystal structure of human farnesyl pyrophosphate synthase in complex with an aminopyridine bisphosphonate, YS0470, and two molecules of inorganic phosphate has been determined. The identity of the phosphate ligands was confirmed by anomalous diffraction data. Human farnesyl pyrophosphate synthase (hFPPS) produces farnesyl pyrophos@@phate, an isoprenoid essential for a variety of cellular processes. The enzyme has been well established as the molecular target of the nitrogen-containing bisphosphonates (N-BPs), which are best known for their antiresorptive effects in bone but are also known for their anticancer properties. Crystal structures of hFPPS in ternary complexes with a novel bisphosphonate, YS0470, and the secondary ligands inorganic phosphate (P{sub i}), inorganic pyrophosphate (PP{sub i}) and isopentenyl pyrophosphate (IPP) have recently been reported. Only the co-binding of the bisphosphonate with either PP{sub i} or IPP resulted in the full closure of the C-@@terminal tail of the enzyme, a conformational change that is required for catalysis and that is also responsible for the potent in vivo efficacy of N-BPs. In the present communication, a co-crystal structure of hFPPS in complex with YS0470 and two molecules of P{sub i} is reported. The unusually close proximity between these ligands, which was confirmed by anomalous diffraction data, suggests that they interact with one another, with their anionic charges neutralized in their bound state. The structure also showed the tail of the enzyme to be fully disordered, indicating that simultaneous binding of two P{sub i} molecules with a bisphosphonate cannot induce the tail-closing conformational change in hFPPS. Examination of homologous FPPSs suggested that this ligand-dependent tail closure is only conserved in the mammalian proteins. The prevalence of P{sub i}-bound hFPPS structures in the PDB raises a question regarding the in vivo relevance of P{sub i} binding to the function of the enzyme.

  13. High-resolution structures of Lactobacillus salivarius transketolase in the presence and absence of thiamine pyrophosphate.

    Science.gov (United States)

    Lukacik, Petra; Lobley, Carina M C; Bumann, Mario; Arena de Souza, Victoria; Owens, Raymond J; O'Toole, Paul W; Walsh, Martin A

    2015-10-01

    Probiotic bacterial strains have been shown to enhance the health of the host through a range of mechanisms including colonization, resistance against pathogens, secretion of antimicrobial compounds and modulation of the activity of the innate immune system. Lactobacillus salivarius UCC118 is a well characterized probiotic strain which survives intestinal transit and has many desirable host-interaction properties. Probiotic bacteria display a wide range of catabolic activities, which determine their competitiveness in vivo. Some lactobacilli are heterofermentative and can metabolize pentoses, using a pathway in which transketolase and transaldolase are key enzymes. L. salivarius UCC118 is capable of pentose utilization because it encodes the key enzymes on a megaplasmid. The crystal structures of the megaplasmid-encoded transketolase with and without the enzyme cofactor thiamine pyrophosphate have been determined. Comparisons with other known transketolase structures reveal a high degree of structural conservation in both the catalytic site and the overall conformation. This work extends structural knowledge of the transketolases to the industrially and commercially important Lactobacillus genus.

  14. Biomineralizing synthesis of mesoporous hydroxyapatite-calcium pyrophosphate polycrystal using ovalbumin as biosurfactant

    International Nuclear Information System (INIS)

    Zhao Hongshi; He Wen; Wang Yingjun; Yue Yuanzheng; Gao Xingguo; Li Zhengmao; Yan Shunpu; Zhou Weijia; Zhang Xudong

    2008-01-01

    Mesoporous polycrystals of hydroxyapatite-calcium pyrophosphate (HA-CPP) are synthesized via a biomineralizing route using ovalbumin as natural biosurfactant. The mesoporous structure of HA-CPP is characterized by means of X-ray diffraction (XRD), N 2 adsorption-desorption isotherms (NADI), Fourier transform infrared spectroscopy (FTIR), transmission electron microscopy (TEM), atom force microscopy (AFM), polarization microscopy (PLM) and stereomicroscopy. The results show that the crystalline grains with an average diameter of 13.2 nm are uniformly distributed along the protein molecule chains, and this results in microsphere-like particles with diameters of 200-300 nm. The highly ordered pores involved in microspheres are found to be approximately 6.6 nm by small-angle XRD. The formation of lyotropic calcium liquid crystal (CLC) plays a key role in the formation and stabilization of the mesoporous structure. A schematic illustration is used to reveal the mechanism of protein-medicated HA-CPP biomineralization, which employs the protein tertiary structure to explain the formation of the porous particles

  15. Novel phosphate-activated macrophages prevent ectopic calcification by increasing extracellular ATP and pyrophosphate

    Science.gov (United States)

    Villa-Bellosta, Ricardo; Hamczyk, Magda R.; Andrés, Vicente

    2017-01-01

    Purpose Phosphorus is an essential nutrient involved in many pathobiological processes. Less than 1% of phosphorus is found in extracellular fluids as inorganic phosphate ion (Pi) in solution. High serum Pi level promotes ectopic calcification in many tissues, including blood vessels. Here, we studied the effect of elevated Pi concentration on macrophage polarization and calcification. Macrophages, present in virtually all tissues, play key roles in health and disease and display remarkable plasticity, being able to change their physiology in response to environmental cues. Methods and results High-throughput transcriptomic analysis and functional studies demonstrated that Pi induces unpolarized macrophages to adopt a phenotype closely resembling that of alternatively-activated M2 macrophages, as revealed by arginine hydrolysis and energetic and antioxidant profiles. Pi-induced macrophages showed an anti-calcifying action mediated by increased availability of extracellular ATP and pyrophosphate. Conclusion We conclude that the ability of Pi-activated macrophages to prevent calcium-phosphate deposition is a compensatory mechanism protecting tissues from hyperphosphatemia-induced pathologic calcification. PMID:28362852

  16. Calcium pyrophosphate dihydrate and hydroxyapatite crystals in a patient with rheumatoid arthritis: Acase report

    Directory of Open Access Journals (Sweden)

    Shereen R Kamel

    2017-01-01

    Full Text Available The association between rheumatoid arthritis (RA and calcium pyrophosphate dihydrate (CPPD crystal deposits can now be easily identified by MSUS, which is a noninvasive technique that can be applied to patients with painful joints and enthesis that are unexplained by rheumatoid activity. In this paper, we report an Egyptian case of a 51-year-old man who had rheumatoid arthritis since 7 years and developed bilateral knee and heel pain of 1.5 months’ duration with gradual onset and progressive course. Radiography revealed features of RA in both hands, as well as features of severe osteoarthritis in both knees with no signs of chondrocalcinosis. Ultrasonography of the joints, Achilles tendon, and plantar fascia detected knee, Achilles tendon, and plantar fascia calcifications, which are characteristic of CPPD, and supraspinatus calcification, which is characteristic of hydroxyapatite (HA deposition. Further investigations revealed no evidence of metabolic disorders. CPPD and HA crystals were identified in his synovial fluid. Subclinical affection with CPPD and HA crystals in RA can be easily detected by ultrasonography, which allows early management to prevent future attacks in RA patients that could lead to exacerbation of joint symptoms that may be missed as rheumatoid disease activity. Diet control and colchicine treatment may be more effective if started early before exacerbation.

  17. Control of plant phosphate homeostasis by inositol pyrophosphates and the SPX domain.

    Science.gov (United States)

    Jung, Ji-Yul; Ried, Martina K; Hothorn, Michael; Poirier, Yves

    2018-02-01

    Proteins containing a SPX domain are involved in phosphate (Pi) homeostasis, including Pi transport and adaptation to Pi deficiency. The SPX domain harbors a basic surface binding Pi at low affinity and inositol pyrophosphates (PP-InsPs) at high affinity. Genetic and biochemical studies revealed that PP-InsPs serve as ligands for the SPX domain. Residues in the PHO1 SPX domain involved in PP-InsPs binding are critical for its Pi export activity, and the interaction between SPX proteins and the PHR1 transcription factor, which results in PHR1 inactivation, is promoted by PP-InsPs. Changes in PP-InsPs levels in response to Pi deficiency may thus contribute to the adaptation of plants to stress via the modulation of the activity of SPX-containing proteins and their interactors. Modulating PP-InsP levels or the affinity/specificity of the SPX domain for PP-InsP could potentially be used to engineer crops to maintain high yield under reduced Pi fertilizer input. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Kinetics of pyrophosphate-driven proton uptake by acidocalcisomes of Leptomonas wallacei

    International Nuclear Information System (INIS)

    Moraes Moreira, Bernardo Luiz; Soares Medeiros, Lia Carolina A.; Miranda, Kildare; Souza, Wanderley de; Hentschel, Joachim; Plattner, Helmut; Barrabin, Hector

    2005-01-01

    In this work, we show the kinetics of pyrophosphate-driven H + uptake by acidocalcisomes in digitonin-permeabilized promastigotes of Leptomonas wallacei. The vacuolar proton pyrophosphatase activity was optimal in the pH range of 7.5-8.0, was inhibited by imidiodiphosphate, and was completely dependent on K + and PPi. H + was released with the addition of Ca 2+ , suggesting the presence of a Ca 2+ /H + antiport. In addition, X-ray elemental mapping associated with energy-filtering transmission electron microscopy showed that most of the Ca, Na, Mg, P, K, Fe, and Zn were located in acidocalcisomes. L. wallacei immunolabeled with antibodies against Trypanosoma cruzi pyrophosphatase show intense fluorescence in cytoplasmatic organelles of size and distribution similar to the acidocalcisomes. Altogether, the results show that L. wallacei acidocalcisomes possess a H + -pyrophosphatase with characteristics of type I V-H + -PPase. However, we did not find any evidence, either for the presence of H + -ATPases or for Na + /H + exchangers in these acidocalcisomes

  19. Pyrophosphate levels strongly influence ascorbate and starch content in tomato fruit

    Directory of Open Access Journals (Sweden)

    Sonia eOsorio

    2013-08-01

    Full Text Available Ascorbate (vitamin C deficiency leads to low immunity, scurvy, and other human diseases and is therefore a global health problem. Given that plants are major ascorbate sources for humans, biofortification of this vitamin in our foodstuffs is of considerable importance. Ascorbate is synthetized by a number of alternative pathways: (i from the glycolytic intermediates D-glucose-6P (the key intermediates are GDP-D-mannose and L-galactose, (ii from the breakdown of the cell wall polymer pectin which uses the methyl ester of D-galacturonic acid as precursor and (iii from myo-inositol as precursor via myo-inositol oxygenase. We report here the engineering of fruit-specific overexpression of a bacterial pyrophosphatase, which hydrolyzes the inorganic pyrophosphate (PPi to orthophosphate (Pi. This strategy resulted in increased vitamin C levels up to 2.5 fold in ripe fruit as well as increasing in the major sugars, sucrose and glucose, yet decreasing the level of starch. When considered together, these finding indicate an intimate linkage between ascorbate and sugar biosynthesis in plants. Moreover, the combined data reveal the importance of PPi metabolism in tomato fruit metabolism and development.

  20. Photoaffinity labeling of cAMP-dependent protein kinase by 4-azido-2-nitrophenyladenylyl pyrophosphate

    International Nuclear Information System (INIS)

    Johnson, D.R.; Ho, H.T.; Wong, S.S.

    1986-01-01

    A photoaffinity analogue of ATP, 4-azido-2-nitrophenyl-adenylyl pyrophosphate (ANAP) has been synthesized to investigate the topographical interaction between the catalytic and the regulatory subunits of the bovine heart type II cAMP-dependent protein kinase. The synthesis involves coupling of 4-azido-2-nitrophenyl phosphate with adenosine 5'-monophosphomorpholidate. ANAP has an absorption maximum at 260 nm (molar absorptivity = 35.4 x 10 3 M -1 cm -1 ) and a shoulder at 320 nm. Kinetically, ANAP inhibits the enzyme competitively against ATP with a Ki of 0.37 mM. The catalytic subunit is inactivated by ANAP upon photolysis in the presence of magnesium ion. ATP protects the enzyme from photoinactivation but the regulatory subunit does not. Gel electrophoretic analysis of the enzyme labeled by [ 14 C]ANAP shows that the photoincorporated ANAP is associated mainly with the catalytic subunit, even when the regulator dimer is in twelve fold excess. Little or no ANAP is found incorporated into the regulator subunit. The data suggest that the photoreactive portion of ANAP does not lie within reach of the regulatory protein when the analogue is bound to the catalytic subunit

  1. Clinical evaluation of skeletal scintigraphy with sup(99m)Tc-pyrophosphate

    Energy Technology Data Exchange (ETDEWEB)

    Sugiura, I; Sasaki, T; Kaneko, M; Watanabe, M [Nagoya Univ. (Japan). Faculty of Medicine

    1975-04-01

    Following about 10 mCi of intravenous administration of sup(99m)Tc-pyrophosphate, skeletal scintiphotography was performed in various skeletal diseases. Skeletal scintiphotograms were taken at about 2 to 3 hours after the administration of the radioisotope with Nuclear Chicago Rho/Gamma III scinticamera. The frontal, occipital and bilateral views of the skull, posterior and lateral views of the spine, anterior and posterior views of ribs, anterior and posterior views of the pelvis and either anterior and posterior views of extremities were scintiphotographed. 17 cases were studied of primary bone tumor (7 benign, 10 malignant), 20 cases of osseous metastasis and 20 cases of non-tumorous conditions. In malignant and benign bone tumors radioactivity is increased at the site of bony changes except for myeloma and leukaemia. In osseous metastasis radioactivity is increased at the site of lesion, even in the early stage. In non-tumorous conditions, radioactivity is also increased at the site of bony changes except for old healed osteomyelitis, old healed tuberculosis of bone and osteoporosis in Cushing's syndrome.

  2. Passivation of Cu-Zn alloy on low carbon steel electrodeposited from a pyrophosphate medium

    Science.gov (United States)

    Yavuz, Abdulcabbar; Yakup Hacıibrahimoğlu, M.; Bedir, Metin

    2018-01-01

    The motivation of this study is to understand whether zinc-based alloy also has a passivation behaviour similar to zinc itself. Cu-Zn alloys were electrodeposited potentiostatically from a pyrophosphate medium on a carbon steel electrode and their corrosion behaviours were studied. Pt and carbon steel electrodes were used in order to examine the corrosion/passivation behaviour of bare Cu, bare Zn and Cu-Zn alloy coatings. The passivation behaviour of all brass-modified electrodes having Zn content between 10% and 100% was investigated. The growth potential affects the morphology and structure of crystals. The brass coatings are more porous than their pure components. The crystalline structure of Cu-Zn alloys can be obtained by changing the deposition potential. The zinc content in brass increases when the deposition voltage applied decreases. However, the growth potential and the ratio of zinc in brass do not affect the passivation behaviour of the resulting alloys. The coatings obtained by applying different growth potentials were immersed in tap water for 24 h to compare their corrosion behaviours with carbon steel having pitting formation.

  3. SURGERY OF SYMPTOMATIC MYOCARDIAL BRIDGING

    Directory of Open Access Journals (Sweden)

    N. Maghamipour N. Safaei

    2007-06-01

    Full Text Available Myocardial bridging with systolic compression of the left anterior descending coronary artery (LAD may be associated with myocardial ischemia. In symptomatic myocardial bridging unresponsive to medical treatment, surgical unroofing of the left LAD can be performed. Little information is available about the long-term prognosis of patients with this coronary anomaly after the surgical unroofing, so we decided to evaluate the result of this operation. A total of 26 patients underwent surgical unroofing of myocardial bridging. Patients had a myocardial bridge of at least 3 cm in length in the middle of LAD and with more than 70% compression during systole. Unroofing was performed with cardiopulmonary bypass in 16 and with off pump technique in 10 patients. In 6 patients repeat angiographies for control of myotomy were done. In one of them a nonsignificant 20% narrowing was seen. Postoperative scintigraphic and angiographic studies demonstrated restoration of coronary flow and myocardial perfusion without residual myocardial bridges under beta-stimulation in 24 patients. Two patients had residual narrowing. With off pump technique, 1 patient had perforation of the right ventricle and 1 patient underwent reoperation because of incomplete unroofing during the first operation. None of the patients with cardiopulmonary bypass technique had residual chest pain or other complications. Surgical unroofing of myocardial bridging with the aid of cardiopulmonary bypass is a safe and easy procedure with low operative risk and with excellent functional results.

  4. Myocardial perfusion SPECT in diabetic patients for detection of coronary artery disease

    International Nuclear Information System (INIS)

    Saeed, M.A.; Fatima, S.; Fatmi, S.; Kureshi, S.

    2003-01-01

    The aim of this study was to evaluate the efficacy of myocardial SPECT perfusion scan in the diagnosis of coronary artery disease in diabetic patients. A total number of thirty diabetic patients (21 males, 9 females) were included in the study. All the patients had strong risk-factors for coronary artery disease (strong family history, chronic smokers, hyperlipidemia, history of chest pain). All patients underwent coronary angiography and stress/rest myocardial perfusion SPECT scans with Tc-99m MIBI (two days protocol). Twenty two patients had significant coronary artery stenosis and 8 had normal coronary arteries. Myocardial perfusion scintigraphy (MPS) was positive in 19 subjects out of the 22 patients with significant stenosis (Sensitivity 86.4%) and negative (false negative) in only three. Out of 8 patients with normal angiography 7 had normal MPS (Specificity 87.5%) whereas only one patient revealed abnormality in the myocardial perfusion study. When compared with coronary angiography the positive predictive value and negative predictive value for Tc-99m MIBI myocardial perfusion scan was 86.4% and 87.5% respectively. In conclusion, Tc-99m MIBI myocardial perfusion scintigraphy is a useful screening modality for the detection of coronary artery disease in diabetic patients. (author)

  5. Assessment of myocardial enhancement during coronary CT angiography in critically ill patients

    Energy Technology Data Exchange (ETDEWEB)

    Mírka, Hynek, E-mail: mirka@fnplzen.cz [Department of Imaging Methods, Faculty of Medicine and University Teaching Hospital in Pilsen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Biomedical Centre, Faculty of Medicine in Plzen, Charles University in Prague, Alej Svobody 76, 304 60 Plzeň (Czech Republic); Ferda, Jiří, E-mail: ferda@fnplzen.cz [Department of Imaging Methods, Faculty of Medicine and University Teaching Hospital in Pilsen, Alej Svobody 80, 304 60 Plzeň (Czech Republic); Baxa, Jan, E-mail: baxaj@fnplzen.cz [Department of Imaging Methods, Faculty of Medicine and University Teaching Hospital in Pilsen, Alej Svobody 80, 304 60 Plzeň (Czech Republic)

    2016-10-15

    Highlights: • There are still unmet needs for the imaging, such as conditions with unknown cause that are not associated with dominant symptoms indicating primarily cardiac cause. • The contribution of the myocardial enhancement evaluation improves to determining the diagnosis of acute myocardial injury and choosing appropriate treatment. • When incorporating the myocardial enhancement assessment into the imaging algorithm, emphasis is placed on a uniform evaluation approach. • The color coded images of the myocardial enhancement in emergency situations help identify the most serious pathologies and shorten the time to adequate therapy. - Abstract: There are still challenges and unmet needs for the imaging techniques, such as conditions of uncertain origin in patients with clinically serious, life-threatening conditions with unknown cause that are not associated with dominant chest pain, ECG changes or other symptoms indicating a possible primarily cardiac or coronary cause. The contribution of the myocardial enhancement evaluation of urgent cardiac CTA scans significantly improves to determining the diagnosis of acute myocardial injury and choosing appropriate treatment. When incorporating the myocardial enhancement assessment into the imaging algorithm of an emergency department, emphasis is placed on a uniform imaging procedure and a uniform evaluation approach. The color coded images of the myocardial enhancement in emergency situations helps identify the most serious pathologies and shorten the time to adequate targeted therapy in patients.

  6. Assessment of myocardial enhancement during coronary CT angiography in critically ill patients

    International Nuclear Information System (INIS)

    Mírka, Hynek; Ferda, Jiří; Baxa, Jan

    2016-01-01

    Highlights: • There are still unmet needs for the imaging, such as conditions with unknown cause that are not associated with dominant symptoms indicating primarily cardiac cause. • The contribution of the myocardial enhancement evaluation improves to determining the diagnosis of acute myocardial injury and choosing appropriate treatment. • When incorporating the myocardial enhancement assessment into the imaging algorithm, emphasis is placed on a uniform evaluation approach. • The color coded images of the myocardial enhancement in emergency situations help identify the most serious pathologies and shorten the time to adequate therapy. - Abstract: There are still challenges and unmet needs for the imaging techniques, such as conditions of uncertain origin in patients with clinically serious, life-threatening conditions with unknown cause that are not associated with dominant chest pain, ECG changes or other symptoms indicating a possible primarily cardiac or coronary cause. The contribution of the myocardial enhancement evaluation of urgent cardiac CTA scans significantly improves to determining the diagnosis of acute myocardial injury and choosing appropriate treatment. When incorporating the myocardial enhancement assessment into the imaging algorithm of an emergency department, emphasis is placed on a uniform imaging procedure and a uniform evaluation approach. The color coded images of the myocardial enhancement in emergency situations helps identify the most serious pathologies and shorten the time to adequate targeted therapy in patients.

  7. Anterior ST depression with acute transmural inferior infarction due to posterior infarction. A vectorcardiographic and scintigraphic study

    International Nuclear Information System (INIS)

    Mukharji, J.; Murray, S.; Lewis, S.E.; Croft, C.H.; Corbett, J.R.; Willerson, J.T.; Rude, R.E.

    1984-01-01

    The hypothesis that anterior ST segment depression represents concomitant posterior infarction was tested in 49 patients admitted with a first transmural inferior myocardial infarction. Anterior ST depression was defined as 0.1 mV or more ST depression in leads V1, V2 or V3 on an electrocardiogram recorded within 18 hours of infarction. Serial vectorcardiograms and technetium pyrophosphate scans were obtained. Eighty percent of the patients (39 of 49) had anterior ST depression. Of these 39 patients, 34% fulfilled vectorcardiographic criteria for posterior infarction, and 60% had pyrophosphate scanning evidence of posterior infarction. Early anterior ST depression was neither highly sensitive (84%) nor specific (20%) for the detection of posterior infarction as defined by pyrophosphate imaging. Of patients with persistent anterior ST depression (greater than 72 hours), 87% had posterior infarction detected by pyrophosphate scan. In patients with inferior myocardial infarction, vectorcardiographic evidence of posterior infarction correlated poorly with pyrophosphate imaging data. Right ventricular infarction was present on pyrophosphate imaging in 40% of patients with pyrophosphate changes of posterior infarction but without vectorcardiographic evidence of posterior infarction. It is concluded that: 1) the majority of patients with acute inferior myocardial infarction have anterior ST segment depression; 2) early anterior ST segment depression in such patients is not a specific marker for posterior infarction; and 3) standard vectorcardiographic criteria for transmural posterior infarction may be inaccurate in patients with concomitant transmural inferior myocardial infarction or right ventricular infarction, or both

  8. Head CT scan

    Science.gov (United States)

    ... scan - orbits; CT scan - sinuses; Computed tomography - cranial; CAT scan - brain ... head size in children Changes in thinking or behavior Fainting Headache, when you have certain other signs ...

  9. Acute anterior myocardial infarction seen on conventional iodine-contrast CT

    Directory of Open Access Journals (Sweden)

    Christian Hagdrup, MD

    2017-09-01

    Full Text Available Diagnosis of acute myocardial infarction (AMI is based on clinical symptoms of chest pain and dyspnea in combination with electrocardiographic changes and a raise in myocardial-specific biomarkers. Imaging is by echocardiography and magnetic resonance. The preferred technique for identification of previous myocardial infarction (MI is magnetic resonance imaging with late gadolinium technique, but in the acute patient echocardiography is applied. In selected cases, important information can be obtained from other imaging modalities. We describe a case of a patient first suspected of an abdominal catastrophe in whom acute MI was diagnosed from a computerized tomography (CT scan with iodine contrast. Our case together with a few other cases reported in the literature demonstrate that contrast enhancement of the myocardium can be important to follow in the acute patient because the CT scans sometimes give a unique opportunity to recognize findings consistent with MI even though the CT scan was performed for another reason.

  10. The use of coronary vasodilators in myocardial imaging with 43K

    International Nuclear Information System (INIS)

    Markov, A.K.; Smith, R.O.; Oglethorpe, N.C.; Lehan, P.H.; Hellems, H.K.

    1980-01-01

    As an alternative procedure to the exercise stress test used in myocardial scanning, vasoactive drugs were employed to elicit deficits in blood flow to myocardial regions supplied by stenotic arteries. The data were collected from 35 dogs, some of which had partial stenosis on either major branch of the left coronary artery, and others which had Ameroid constrictor implants. The effects of lidoflazine, dipyridamole, and nitroglycerin on coronary hemodynamics and myocardial dispersion of 43 K in animals with partial stenosis were evaluated in ten acute experiments. In the pilot studies, four rapid serial rectilinear control scans from 43 K (750 μCi) were reported; dipyridamole, lidoflazine, or nitroglycerin were then administered intravenously. When the selected drug reached a peak vasodilatative effect, a second equal bolus of 43 K was given and four additional scans recorded. The control scans from dogs with partial stenosis or an Ameroid constrictor showed homogeneous distribution of the myocardial 43 K. When drugs were used, the region supplied by compromised circulation became apparent because of lower counts when compared to the normally perfused ones. Coronary vasodilators, as opposed to postexercise in myocardial imaging, have a lesser effect on cardiac dynamics, peripheral hemodynamics, and also double the 43 K uptake in normally perfused myocardium. (orig.) [de

  11. Relative bioavailability of micronized, dispersible ferric pyrophosphate added to an apple juice drink.

    Science.gov (United States)

    Roe, Mark A; Collings, Rachel; Hoogewerff, Jurian; Fairweather-Tait, Susan J

    2009-03-01

    Food iron fortification is a sustainable and relatively simple strategy to reduce/prevent iron deficiency but is a challenge for the food industry because of possible adverse organoleptic changes caused by the added iron. A micronized dispersible ferric pyrophosphate, trademarked as SunActive Fe, has recently been developed. SunActive Fe has a small particle size, is water soluble and may be suitable for fortifying liquid products. To determine the relative bioavailability of SunActive Fe and its suitability for addition to pure apple juice. Iron absorption from SunActive Fe added to pure apple juice (Minute Maid) was compared with absorption from ferrous sulphate, a highly bioavailable form of iron, in 15 women with relatively low iron stores. Both forms of iron were enriched with an iron stable isotope and iron absorption from the apple juice drinks was calculated from the isotopic enrichment of red blood cells 14 days after the last test meal. Although mean absorption of iron from SunActive Fe was significantly lower than from ferrous sulphate (5.5% compared with 9.1%), the mean bioavailability of SunActive Fe iron relative to ferrous sulphate was 0.6, indicating that it is a good source of bioavailable iron. Iron Absorption from SunActive Fe was positively correlated (r = 0.97, P = 0.01) with absorption from ferrous sulphate, and negatively correlated with serum ferritin concentration (ferrous sulphate r = -0.81, P apple juice and is a potentially useful fortificant for liquid food products.

  12. Ultrasonographic findings of Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease.

    Science.gov (United States)

    Ellabban, Abdou S; Kamel, Shereen R; Abo Omar, Hanaa A S; El-Sherif, Ashraf M H; Abdel-Magied, Rasha A

    2012-04-01

    The aims of the study were to detect the frequency of involvement of the Achilles tendon and plantar fascia in patients with calcium pyrophosphate deposition disease (CPPD) by high-frequency gray-scale ultrasonography (US) and power Doppler sonography (PDS) and to correlate these findings with demographic and clinical data. Two groups of patients were enrolled: group I (38 patients with CPPD) and group II (22 patients with knee OA). US/PDS examination of the heels was performed to both groups. In the CPPD group, US/PDS examination of the Achilles tendon revealed: calcification in 57.9%, enthesophytosis in 57.9%, enthesopathy in 23.7%, vascular sign in 21%, bursitis in 13.2%, and cortical bone irregularity in 10.5%. US/PDS examination of plantar fascia in the CPPD group revealed: calcification in 15.8%, cortical bone irregularity in 78.9%, enthesophytosis in 60.5%, and planter fasciitis in 42.1%. In patients with CPPD, age was significantly correlated with enthesophytosis and deep retrocalcaneal bursitis (p = 0.01 and p = 0.04, respectively). Heel tenderness and posterior talalgia were significantly correlated with Achilles tendon enthesopathy, vascular sign, and deep retrocalcaneal bursitis (p = 0.0001 for each). Inferior talalgia was significantly correlated with plantar fasciitis (p = 0.0001). The sensitivity of ultrasonography for detection of calcifications in Achilles tendon and plantar fascia was 57.9% and 15.8%, respectively, and the specificity was 100% for both. To conclude, ultrasonographic Achilles tendon and plantar fascia calcifications are frequent findings in patients with CPPD. These calcifications have a high specificity and can be used as a useful indirect sign of CPPD.

  13. Membrane Topology and Biochemical Characterization of the Escherichia coli BacA Undecaprenyl-Pyrophosphate Phosphatase.

    Directory of Open Access Journals (Sweden)

    Guillaume Manat

    Full Text Available Several integral membrane proteins exhibiting undecaprenyl-pyrophosphate (C55-PP phosphatase activity were previously identified in Escherichia coli that belonged to two distinct protein families: the BacA protein, which accounts for 75% of the C55-PP phosphatase activity detected in E. coli cell membranes, and three members of the PAP2 phosphatidic acid phosphatase family, namely PgpB, YbjG and LpxT. This dephosphorylation step is required to provide the C55-P carrier lipid which plays a central role in the biosynthesis of various cell wall polymers. We here report detailed investigations of the biochemical properties and membrane topology of the BacA protein. Optimal activity conditions were determined and a narrow-range substrate specificity with a clear preference for C55-PP was observed for this enzyme. Alignments of BacA protein sequences revealed two particularly well-conserved regions and several invariant residues whose role in enzyme activity was questioned by using a site-directed mutagenesis approach and complementary in vitro and in vivo activity assays. Three essential residues Glu21, Ser27, and Arg174 were identified, allowing us to propose a catalytic mechanism for this enzyme. The membrane topology of the BacA protein determined here experimentally did not validate previous program-based predicted models. It comprises seven transmembrane segments and contains in particular two large periplasmic loops carrying the highly-conserved active site residues. Our data thus provide evidence that all the different E. coli C55-PP phosphatases identified to date (BacA and PAP2 catalyze the dephosphorylation of C55-PP molecules on the same (outer side of the plasma membrane.

  14. Effect of inorganic additive sodium pyrophosphate tetrabasic on positive electrolytes for a vanadium redox flow battery

    International Nuclear Information System (INIS)

    Park, Se-Kook; Shim, Joonmok; Yang, Jung Hoon; Jin, Chang-Soo; Lee, Bum Suk; Lee, Young-Seak; Shin, Kyoung-Hee; Jeon, Jae-Deok

    2014-01-01

    Sodium pyrophosphate tetrabasic (SPT) is employed as an inorganic additive in the positive electrolyte of a vanadium redox flow battery (VRFB) to improve its long-term stability and electrochemical performance. The results of precipitation tests show that the long-term stability of positive electrolytes (2 MV(V) solution in 4 M total sulfates with 0.05 M SPT additive) is improved compared to the blank one. UV-vis and cyclic voltammetry (CV) measurements also suggest that the addition of SPT can effectively delay the formation of precipitation in positive electrolytes, and no new substances are formed in V(V) electrolytes with SPT. The calcined precipitates extracted from the electrolytes with and without a SPT additive are identified as V 2 O 5 by X-ray diffraction (XRD) analysis. A VRFB single-unit cell employing positive electrolytes with an additive exhibits the high energy efficiency of 74.6% at a current density of 40 mA cm 2 at the 500 th cycle at 20°C, compared to 71.8% for the cell employing the electrolyte without an additive. Moreover, the cell employing the electrolyte with an additive exhibits less discharge capacity fading during cycling in comparison with the pristine one. The disassembled cell without an additive shows a large number of V 2 O 5 precipitation particles on the felt electrode after 500 cycles. Meanwhile, the felt electrode of the cell with an additive has little precipitation. That precipitation gives rise to an imbalance between the positive and negative half-cell electrolytes, which results in a significant capacity loss. The additive has shown positive results under limited laboratory short-term and small-scale conditions

  15. Identification of the inorganic pyrophosphate metabolizing, ATP substituting pathway in mammalian spermatozoa.

    Science.gov (United States)

    Yi, Young-Joo; Sutovsky, Miriam; Kennedy, Chelsey; Sutovsky, Peter

    2012-01-01

    Inorganic pyrophosphate (PPi) is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1) in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF) rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS) and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies.

  16. Identification of the inorganic pyrophosphate metabolizing, ATP substituting pathway in mammalian spermatozoa.

    Directory of Open Access Journals (Sweden)

    Young-Joo Yi

    Full Text Available Inorganic pyrophosphate (PPi is generated by ATP hydrolysis in the cells and also present in extracellular matrix, cartilage and bodily fluids. Fueling an alternative pathway for energy production in cells, PPi is hydrolyzed by inorganic pyrophosphatase (PPA1 in a highly exergonic reaction that can under certain conditions substitute for ATP-derived energy. Recombinant PPA1 is used for energy-regeneration in the cell-free systems used to study the zymology of ATP-dependent ubiquitin-proteasome system, including the role of sperm-borne proteasomes in mammalian fertilization. Inspired by an observation of reduced in vitro fertilization (IVF rates in the presence of external, recombinant PPA1, this study reveals, for the first time, the presence of PPi, PPA1 and PPi transporter, progressive ankylosis protein ANKH in mammalian spermatozoa. Addition of PPi during porcine IVF increased fertilization rates significantly and in a dose-dependent manner. Fluorometric assay detected high levels of PPi in porcine seminal plasma, oviductal fluid and spermatozoa. Immunofluorescence detected PPA1 in the postacrosomal sheath (PAS and connecting piece of boar spermatozoa; ANKH was present in the sperm head PAS and equatorial segment. Both ANKH and PPA1 were also detected in human and mouse spermatozoa, and in porcine spermatids. Higher proteasomal-proteolytic activity, indispensable for fertilization, was measured in spermatozoa preserved with PPi. The identification of an alternative, PPi dependent pathway for ATP production in spermatozoa elevates our understanding of sperm physiology and sets the stage for the improvement of semen extenders, storage media and IVF media for animal biotechnology and human assisted reproductive therapies.

  17. Isoprenoid Pyrophosphate-Dependent Transcriptional Regulation of Carotenogenesis in Corynebacterium glutamicum

    Directory of Open Access Journals (Sweden)

    Petra Peters-Wendisch

    2017-04-01

    Full Text Available Corynebacterium glutamicum is a natural producer of the C50 carotenoid decaprenoxanthin. The crtEcg0722crtBIYEb operon comprises most of its genes for terpenoid biosynthesis. The MarR-type regulator encoded upstream and in divergent orientation of the carotenoid biosynthesis operon has not yet been characterized. This regulator, named CrtR in this study, is encoded in many actinobacterial genomes co-occurring with terpenoid biosynthesis genes. CrtR was shown to repress the crt operon of C. glutamicum since DNA microarray experiments revealed that transcript levels of crt operon genes were increased 10 to 70-fold in its absence. Transcriptional fusions of a promoter-less gfp gene with the crt operon and crtR promoters confirmed that CrtR represses its own gene and the crt operon. Gel mobility shift assays with purified His-tagged CrtR showed that CrtR binds to a region overlapping with the −10 and −35 promoter sequences of the crt operon. Isoprenoid pyrophosphates interfered with binding of CrtR to its target DNA, a so far unknown mechanism for regulation of carotenogenesis. The molecular details of protein-ligand interactions remain to be studied. Decaprenoxanthin synthesis by C. glutamicum wild type was enhanced 10 to 30-fold upon deletion of crtR and was decreased 5 to 6-fold as result of crtR overexpression. Moreover, deletion of crtR was shown as metabolic engineering strategy to improve production of native and non-native carotenoids including lycopene, β-carotene, C.p. 450 and sarcinaxanthin.

  18. Depression following myocardial infarction

    DEFF Research Database (Denmark)

    Larsen, Karen Kjær

    2013-01-01

    whether the mental burden of MI is so heavy that it increases the risk of suicide. Although post-MI depression is common and burdensome, the condition remains under-recognised and under-treated. The development of new strategies to improve the quality of care for people with post-MI depression requires...... between post-MI depression and new cardiovascular events or death, taking potential mediators into account (Paper III); 4. To examine the association between MI and suicide (Paper IV). Two different study designs were employed: a population-based cohort study using data obtained from registers......Myocardial infarction (MI) is a severe life event that is accompanied by an increased risk of depression. Mounting evidence suggests that post-MI depression is associated with adverse outcomes, but the underlying mechanisms of this association remain unclear, and no previous studies have examined...

  19. Development of Dy3+ activated K2MgP2O7 pyrophosphate phosphor for energy saving lamp

    International Nuclear Information System (INIS)

    Kohale, R.L.; Dhoble, S.J.

    2013-01-01

    Present work reports, synthesis of Dy 3+ activated K 2 MgP 2 O 7 pyrophosphate phosphor by using modified solid state diffusion that has been studied for its X-ray diffraction pattern (XRD). Furthermore, the chromaticity coordinate values were estimated from emission spectra of K 2 MgP 2 O 7 . The photoluminescence emission spectra of the phosphors having an excitation at around 351 nm (mercury free) showed two distinguishing bands centered at around 485 nm (blue) and 575 nm (yellow) corresponding to 4 F 9/2 → 6 H 15/2 and 4 F9 /2 → 6 H 13/2 transitions of Dy 3+ , respectively. These phosphors have strong absorption in the near UV region. K 2 MgP 2 O 7 pyrophosphate phosphor is suitable for color converter using UV light as the primary light source, which can be used as a blue/yellow phosphor excited by n-UV LED chip and mixed with other color emission phosphors to obtain white light. The 300–400 nm is Hg-free excitation (mercury excitation is 85% 254 nm wavelength of light and 15% other wavelengths), which is characteristic of solid-state lighting phosphors. Hence PL emission in trivalent dysprosium may be efficient photoluminescent materials for solid-state lighting phosphors. The intact study reveals that the present phosphor have promising applications in the lamp industry especially for solid state lighting (mercury-free excited lamp phosphor) and white light LED. -- Highlights: ► Dy 3+ activated pyrophosphate based phosphor prepared by modified solid state diffusion. ► PL emission spectrum of Dy 3+ ion under 351 nm excitation (Hg-free). ► PL emission at 485 nm (blue), 575 nm (yellow) emission. ► K 2 MgP 2 O 7 : Dy 3+ is expected to be a potential candidate for application in n-UV white LEDs and solid state lighting

  20. Redox Additive-Improved Electrochemically and Structurally Robust Binder-Free Nickel Pyrophosphate Nanorods as Superior Cathode for Hybrid Supercapacitors.

    Science.gov (United States)

    Sankar, Kalimuthu Vijaya; Seo, Youngho; Lee, Su Chan; Chan Jun, Seong

    2018-03-07

    For several decades, one of the great challenges for constructing a high-energy supercapacitor has been designing electrode materials with high performance. Herein, we report for the first time to our knowledge a novel hybrid supercapacitor composed of battery-type nickel pyrophosphate one-dimensional (1D) nanorods and capacitive-type N-doped reduced graphene oxide as the cathode and anode, respectively, in an aqueous redox-added electrolyte. More importantly, ex situ microscopic images of the nickel pyrophosphate 1D nanorods revealed that the presence of the battery-type redox additive enhanced the charge storage capacity and cycling life as a result of the microstructure stability. The nickel pyrophosphate 1D nanorods exhibited their maximum specific capacitance (8120 mF cm -2 at 5 mV s -1 ) and energy density (0.22 mWh cm -2 at a power density of 1.375 mW cm -2 ) in 1 M KOH + 75 mg K 3 [Fe(CN) 6 ] electrolyte. On the other side, the N-doped reduced graphene oxide delivered an excellent electrochemical performance, demonstrating that it was an appropriate anode. A hybrid supercapacitor showed a high specific capacitance (224 F g -1 at a current density of 1 A g -1 ) and high energy density (70 Wh kg -1 at a power density of 750 W kg -1 ), as well as a long cycle life (a Coulombic efficiency of 96% over 5000 cycles), which was a higher performance than most of those in recent reports. Our results suggested that the materials and redox additive in this novel design hold great promise for potential applications in a next-generation hybrid supercapacitor.

  1. Correlation between semiquantitative myocardial perfusion score and absolute myocardial flow in 13N-ammonia PET

    International Nuclear Information System (INIS)

    Lee, Byeong Il; Kim, Jung Young; Min, Jung Joon; Song, Ho Chun; Bom, Hee Seung; Kim, Kye Hun; Kim, Su Jin; Lee, Jae Sung

    2007-01-01

    13 N-ammonia is a well known radiopharmaceutical for the measurement of a myocardial blood flow (MBF) non-invasively using PET-CT. In this study, we investigated a correlation between MBF obtained from dynamic imaging and myocardial perfusion score (MPS) obtained from static imaging for usefulness of cardiac PET study. Twelve patients (11 males, 1 female, 57.9 ± 8.6 years old) with suspicious coronary artery disease underwent PET-CT scan. Dynamic scans (6 min: 5 sec X 12, 10 sec X 6, 20 sec X 3, and 30 sec X 6) were initiated simultaneously with bolus injection of 11 MBq/kg 13 N-ammonia to acquire rest and stress image. Gating image was acquired during 13 minutes continuously. Nine-segment model (4 basal walls, 4 mid walls, and apex) was used for a measurement of MBF. Time activity curve of input function and myocardium was extracted from ROI methods in 9 regions for quantification. The MPS were evaluated using quantitative analysis software. To compare between 20-segment model and 9-segment model, 6 basal segments were excluded and averaged segmental scores were used. There are weak correlation between MBF (rest, 0.18-2.38 ml/min/g; stress, 0.40-4.95 ml/min/g) and MPS (rest 22-91%, stress, 14-90%), however the correlation coefficient between corrected MBF and MPS in rest state was higher than stress state (rest r=0.59; stress r=0.80). As a thickening increased, correlation between MBF and MPS also showed good correlation at each segments. Corrected and translated MPS as its characteristics using 13 N-ammonia showed good correlation with absolute MBF measured by dynamic image in this study. Therefore, we showed MPS is one of good indices which reflect MBF. We anticipate PET-CT could be used as useful tool for evaluation of myocardial function in nuclear cardiac study

  2. Molecular cloning and expression of Chimonanthus praecox farnesyl pyrophosphate synthase gene and its possible involvement in the biosynthesis of floral volatile sesquiterpenoids.

    Science.gov (United States)

    Xiang, Lin; Zhao, Kaige; Chen, Longqing

    2010-01-01

    Farnesyl pyrophosphate (FPP) synthase catalyzes the biosynthesis of FPP, which is the precursors of sesquiterpenoids such as floral scent volatiles, from isopentenyl pyrophosphate (IPP) and dimethylallyl pyrophosphate (DMAPP). cDNA encoding wintersweet (Chimonanthus praecox L.) FPP synthase was isolated by the RT-PCR and RACE methods. The deduced amino acid sequence showed a high identity to plant FPP synthases. Expression of the gene in Escherichia coli yielded FPPS activity that catalyzed the synthesis of FPP as a main product. Tissue-specific and developmental analyses of the mRNA levels of CpFPPS and volatile sesquiterpenoids levels in C. praecox flowers revealed that the FPPS may play a regulatory role in floral volatile sesquiterpenoids of wintersweet. Copyright © 2010 Elsevier Masson SAS. All rights reserved.

  3. The peculiarities of electrochemical deposition and morphology of ZnMn alloy coatings obtained from pyrophosphate electrolyte

    Directory of Open Access Journals (Sweden)

    Bučko Mihael M.

    2011-01-01

    Full Text Available The first successful attempt to electrodeposit ZnMn alloy coatings from alkaline bath was made only a few years ago. In this kind of solution, potassium pyrophosphate (K4P2O7 serves both as a complexing agent and as the basic electrolyte. The aim of this work was to study the electrodeposition process and properties of ZnMn alloy coatings deposited from pyrophosphate solution, with a new kind of alkaline pyrophosphate bath. Namely, chloride salts were used as the source of metal ions and ascorbic acid was used as reducing agent. The composition of the plating solution was as follows: 1 mol dm-3 K4P2O7 + 0.017 mol dm-3 ascorbic acid + 0.05 mol dm-3 ZnCl2 + 0.05 mol dm-3 MnCl2•4H2O. Cathodic processes during the alloy electrodeposition were investigated using linear voltammetry. The influence of addition of small amounts of ascorbic acid on the cathodic processes was established. It was shown that this substance inhibits hydrogen evolution and increases the current efficiency of alloy deposition. The current efficiency in the plating bath examined was in the range of 25 and 30%, which was quite higher as compared to the results reported in the literature for electrodeposition of ZnMn alloy from pyrophosphate bath. Electrodeposition of ZnMn alloys was performed galvanostatically on steel panels, at current densities of 20120 mA cm-2. The coatings with the best appearance were obtained at current densities between 30 and 80 mA cm-2. The surface morphology studies, based on atomic force microscopy measurements, showed that morphology of the deposits is highly influenced by deposition current density. ZnMn coating deposited at 30 mA cm-2 was more compact and possessed more homogeneous structure (more uniform agglomeration size than the coating deposited at 80 mA cm-2. Such dependence of morphology on the current density could be explained by the high rate of hydrogen evolution reaction during the electrodeposition process.

  4. Sequential scintigraphy of the kidneys and joints with 99mTc-pyrophosphate in patients with rheumatic arthritis

    International Nuclear Information System (INIS)

    Askerov, N.M.; Dzhafarov, G.A.

    1990-01-01

    The proposed method of sequential scintigraphy of the kidneys and joints in a single administration of 99m Tc-pyrophosphate permits obtaining objective information on function and topography of the kidneys and pyodestructive processes in the joints. Dynamic scintigraphy helps to assess visually renal hemodynamics and the anatomotopographic position of the kidney and to obtain exhaustive information on accumulative-evacuatory function of each kidney individually. Scintigraphy also helps to investigate all the joints and to detect pyoinflammatory changes in them. The proposed method considerably reduces the time of investigation and lessens radiation exposure of patients, permitting repeated investigations to assess and correct the treatment of patients with rheumatic arthritis

  5. Experimental study of the radiation effects on the bone growth. Changes in Tc-99m pyrophosphate bone imaging

    International Nuclear Information System (INIS)

    Ohtake, H.; Sakai, Y.; Morita, S.; Kikuchi, S.; Bussaka, Y.; Oshibuchi, M.; Fukae, S.; Kaneyuki, Y.; Umezaki, N.

    1983-01-01

    Bones of immature rabbits during growth period were irradiated and followed up with bone scintigraphy with Tc-99m pyrophosphate. The accumulation ratio of radionuclide was decreased on the irradiated bone from an early period compared to the control side, and the decrease was more pronounced as the dose of irradiation increased. In groups irradiated with less than 4,000 rad, the ratio reached the minimum at 5 weeks, followed by a gradual recovery. These changes were evaluated with reference to the inhibition on longitudinal growth of the bone

  6. Thallium-201 for myocardial imaging: appearance of the normal heart

    International Nuclear Information System (INIS)

    Cook, D.J.; Bailey, I.; Strauss, H.W.; Rouleau, J.; Wagner, H.N. Jr.; Pitt, B.

    1976-01-01

    Thallium-201 myocardial perfusion images were obtained from 13 healthy adults after tracer administration both at rest and at maximal stress. On the rest-injected scan, tracer was seen in left ventricular myocardium, liver, and spleen. In two subjects with resting tachycardia, the right ventricular myocardium was slightly visualized after tracer injection at rest. When tracer was administered at stress, the left ventricular activity was more nearly homogeneous and the left ventricle was better defined on the scan. The left-ventricle-to-lung-background activity ratio increased from 2.4 at rest to 3.4 at stress. The right ventricular myocardium was seen on the stress-injected scan. Phantom studies, performed to define the optimum position for visualization of lesions, showed that small lesions were best defined when seen either en face or in tangent. Scans should be performed at stress whenever possible and multiple views are essential

  7. Myocardial scintigraphy: methods and indications

    International Nuclear Information System (INIS)

    Knapp, W.H.

    1993-01-01

    Myocardial scintigraphy comprises perfusion imaging using TI-201 or - more recently - Tc-99m-labeled compounds with high affinity to myocytes. Imaging with these agents has become an important procedure in the detection of coronary artery disease, particularly in patients with non-diagnostic stress-ECG, in the functional evaluation of coronary stenoses after angiographical documentation in order to meet the adequate therapy decision, in therapy monitoring and follow-up, in the post infarction assessment of myocardial viability and differentiation between severe ischemia and scar and, occasionally, in acute ischemia. The use of positron emitters does not offer significant advantages for mere perfusion imaging, but is indispensable for the scintigraphic investigation of certain aspects of myocardial metabolism, particularly for the differentiation of viable ischemic wall segments from irreversibly damaged tissue. Imaging of myocardial necrosis has been improved by the introduction of labeled antimyosin antibody fragments and offers a considerable clinical potential in the diagnosis of myocarditis and cardiac transplant rejection. Neurohumoral aspects are increasingly involved in our understanding of myocardial failure. Scintigraphy of innervation/neurotransmission contributes to the investigation of pathophysiological alterations in myocardial insufficiency and in heart transplants. (orig.) [de

  8. Electrical conductivity of titanium pyrophosphate between 100 and 400 °C: effect of sintering temperature and phosphorus content

    DEFF Research Database (Denmark)

    Lapina, Alberto; Chatzichristodoulou, Christodoulos; Hallinder, Jonathan

    2014-01-01

    The synthesis of titanium pyrophosphate is carried out, and the material is sintered at different temperatures between 370 and 970 °C. Yttrium is added during the synthesis to act as acceptor dopant, but it is mainly present in the material in secondary phases. The conductivity is studied systema...... at 300–390 °C. Slow loss of phosphorus by evaporation over time and changes in the distribution of the amorphous phase during testing are suggested as causes of conductivity degradation above 220 °C.......The synthesis of titanium pyrophosphate is carried out, and the material is sintered at different temperatures between 370 and 970 °C. Yttrium is added during the synthesis to act as acceptor dopant, but it is mainly present in the material in secondary phases. The conductivity is studied...... to an amorphous secondary phase at the grain boundaries, associated with the presence of excess phosphorus in the samples. A contribution to the conductivity by point defects in the bulk may explain the conductivity trend in dry air and the difference in conductivity between oxidizing and reducing atmospheres...

  9. Thermodynamic limits on the size and size distribution of nucleic acids synthesized in vitro: the role of pyrophosphate hydrolysis.

    Science.gov (United States)

    Peller, L

    1977-02-08

    The free-energy change of phosphodiester bond formation from nucleoside triphosphates is more favorable than with nucleoside diphosphates as substrates. Base-stacking interactions can make significant contributions to both delta G degrees ' values. Pyrophosphate hydrolysis when it accompanies the former reaction dominates all thermodynamic considerations. Three experimental situations are discussed in which high-molecular-weight polynucleotides are synthesized without a strong driving force for covalent bond formation. For one of these, a kinetic scheme is presented which encompasses an early narrow Poisson distribution of chain lengths with ultimate passage to a disperse equilibrium population of chain sizes. Hydrolytic removal of pyrophosphate expands the time scale for this undesirable process by a factor of 10(9), while it enormously elevates the thermodynamic ceiling for the average degrees of polymerization in the other two examples. The electron micrographically revealed broad size population from an early study of partial replication of a T7 DNA template is found to adhere (fortuitously) to a disperse most probable representation. Some possible origins are examined for the branched structures in this product, as well as in a later investigation of replication of this nucleic acid. The achievement of both very high molecular weights and sharply peaked size distributions in polynucleotides synthesized in vitro will require coupling to inorganic pyrophosphatase action as in vivo.

  10. Advantages and limits of sup(99m)Tc pyrophosphate scintigraphy in the study of joint diseases

    International Nuclear Information System (INIS)

    Caillard, J.-F.

    1975-01-01

    The results of sup(99m)Tc pyrophosphate bone scintigraphy are studied for a wide range of joint diseases. 215 scintigraphs are analysed, the results compared with those of authors who have used not only Tc phosphates but also other isotopes after comparison of their advantages and disadvantages, and possible applications suggested for each type of lesion. - The 99m Tc pyrophosphate scintigraphic examination is simple, harmless (a whole-skeleton examination delivers only 80 millirads to the narrow whereas a set of spine and pelvis X-rays delivers 325), reliable and highly sensitive, often anticipating data from radiographic examinations. - In the majority of developing joint diseases of whatever kind, apart from arthroses and certain osteolytic lesions unaccompanied by any healing reaction, a hyperfixation is observed. Generally speaking a scintigraph may be requested whenerver an evolutive bone lesion is suspected in the absence of clinical, radiological and biological evidence. The major disadvantage of the method is that, being highly sensitive, it lacks specificity and is hence unable alone to provide an etiological diagnosis [fr

  11. Differential diagnosis between secondary hyperparathyroidism and aluminum intoxication in uremic patients: Usefulness of 99mTc-pyrophosphate bone scintigraphy

    International Nuclear Information System (INIS)

    Kinnaert, P.; Van Hooff, I.; Schoutens, A.

    1989-01-01

    Forty-one patients in chronic end-stage renal failure and 4 patients with a functioning kidney transplant presented with spontaneous hypercalcemia or intolerance to vitamin D3 sterols and/or oral calcium supplements. Bone iliac crest biopsy with aluminum staining and Tc-pyrophosphate bone scintigraphy with determination of Fogelman score were performed in all cases. Two patients had aluminum-induced osteomalacia (AL O). Thirty-eight biopsies showed renal osteodystrophy (secondary hyperparathyroidism or various combinations of osteitis fibrosa and osteomalacia): 19 with positive staining for aluminum (RO + AL) and 19 without aluminum deposits (RO). The series also comprised 2 cases of pure osteomalacia (OM), 2 cases of osteoporosis (OP), and 1 case of osteoporosis with aluminum accumulation (OP + AL). Mean Fogelman score in RO patients (9.1 +/- 0.3) was significantly higher than in all other categories (5.9 +/- 0.5 for RO + AL, and scores ranging from 0 to 8 in the last 7 patients, p less than 0.01). Patients with massive aluminum accumulation in bone (greater than 75% of the total trabecular surface) showed no or very low uptake of the isotope by the skeleton. Fogelman scores of 9 or higher were always associated with histological secondary hyperparathyroidism. 99m Tc-pyrophosphate bone scintigraphy is helpful to distinguish aluminum intoxication from secondary hyperparathyroidism in uremic patients

  12. Identification of myocardial diffuse fibrosis by 11 heartbeat MOLLI T 1 mapping

    DEFF Research Database (Denmark)

    Vassiliou, Vassilios S; Wassilew, Katharina; Cameron, Donnie

    2017-01-01

    OBJECTIVES: Our objectives involved identifying whether repeated averaging in basal and mid left ventricular myocardial levels improves precision and correlation with collagen volume fraction for 11 heartbeat MOLLI T 1 mapping versus assessment at a single ventricular level. MATERIALS AND METHODS...... and ECV. To assess correlation of T 1 mapping with collagen volume fraction, a separate cohort of ten aortic stenosis patients scheduled to undergo surgery underwent one CMR scan with this 11 heartbeat MOLLI scheme, followed by intraoperative tru-cut myocardial biopsy. Six models of myocardial diffuse...... fibrosis assessment were established with incremental inclusion of imaging by averaging of the basal and mid-myocardial left ventricular levels, and each model was assessed for precision and correlation with collagen volume fraction. RESULTS: A model using 11 heart beat MOLLI imaging of two basal and two...

  13. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by 201Tl myocardial SPECT

    International Nuclear Information System (INIS)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-01-01

    201 Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by 201 Tl myocardial SPECT was high, and 201 Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author)

  14. Sequential change of cardiomyopathy of Duchenne muscular dystrophy by /sup 201/Tl myocardial SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Ono, Seiji; Sugimoto, Seiichirou; Inoue, Kenjirou; Jinnouchi, Seishi; Hoshi, Hiroaki; Watanabe, Katsushi.

    1989-03-01

    /sup 201/Tl myocardial SPECT were performed to evaluate of cardiomyopathy in Duchenne type of progressive muscular dystrophy (DMD). Follow up SPECT images of the same patients were also obtained about 1 year after the first scan. Cases subjected to study were 10 DMD. At the first study the hypoperfusion area of the left ventricular muscle were observed in 6 cases (60%) out of 10. At the second study the hypoperfusion areas became wider and lower in 4 out of 6 cases (66.7%). The new hypoperfusion area which was not demonstrated at the first study was observed at the second study in one case of these cases. These results suggested that the positive rate of cardiomyopathy in DMD by /sup 201/Tl myocardial SPECT was high, and /sup 201/Tl myocardial SPECT is a useful examination to detect the change of myocardial damage in DMD. (author).

  15. Acute Myocardial Infarction Patients

    Directory of Open Access Journals (Sweden)

    Bruce Ovbiagele

    2011-01-01

    Full Text Available Background. Diabetes mellitus (DM confers high vascular risk and is a growing national epidemic. We assessed clinical characteristics and prevalence of diagnosed DM among patients hospitalized with acute myocardial infarction (AMI in the US over the last decade. Methods. Data were obtained from all states within the US that contributed to the Nationwide Inpatient Sample. All patients admitted to hospitals between 1997 and 2006 with a primary discharge diagnosis of AMI were included. Time trends in the proportion of these patients with DM diagnosis were computed. Results. The portion of patients with comorbid diabetes among AMI hospitalizations increased substantially from 18% in 1997 to 30% in 2006 (<.0001. Absolute numbers of AMI hospitalizations in the US decreased 8% (from 729, 412 to 672, 243, while absolute numbers of AMI hospitalizations with coexisting DM rose 51% ((131, 189 to 198, 044, both (<.0001. Women with AMI were significantly more likely to have DM than similarly aged men, but these differences diminished with increasing age. Conclusion. Although overall hospitalizations for AMI in the US diminished over the last decade, prevalence of diabetes rose substantially. This may have important consequences for the future societal vascular disease burden.

  16. Early spontaneous intermittent myocardial reperfusion during acute myocardial infarction is associated with augmented thrombogenic activity and less myocardial damage

    NARCIS (Netherlands)

    Haider, A.W.; Andreotti, F.; Hackett, D.R.; Tousoulis, D.; Kluft, C.; Maseri, A.; Davies, G.J.

    1995-01-01

    Objectives. This study investigated the influence of early spontaneous intermittent reperfusion on the extent of myocardial damage and its relation to endogenous hemostatic activity, Background. In the early phase of acute myocardial infarction coronary occlusion is often intermittent, even before

  17. Brain PET scan

    Science.gov (United States)

    ... results on a PET scan. Blood sugar or insulin levels may affect the test results in people with diabetes . PET scans may be done along with a CT scan. This combination scan is called a PET/CT. Alternative Names Brain positron emission tomography; PET scan - brain References Chernecky ...

  18. Thallium-201 myocardial imaging in acute-myocardial infarction

    International Nuclear Information System (INIS)

    Wackers, F.J.Th.; Lie, K.I.; Sokole, E.B.; Wellens, H.J.J.; Samson, G.; Schoot, J.B. van der

    1980-01-01

    Thallium-201 scintigraphy has proven to be an early and highly sensitive technique to detect myocardial perfusion abnormalities in patients with acute myocardial infarction. During the early phase of acute myocardial infarction, patients may be hemodynamically and electrically unstable. Therefore, scintigraphy is performed preferably at the bed side in the Coronary Care Unit using a mobile gamma camera. Additionally, in order to shorten imaging time in these often critically ill patients, the authors recommend injecting no less than 2 mCi of 201 Tl. Using this dosage, the imaging time per view will be approximately five minutes. Routinely, three views are taken: the first view is a supine 45 0 left-anterior-oblique view, followed by a supine anterior view and finally a left-lateral view, the latter with the patient turned on the right side. (Auth.)

  19. Myocardial perfusion imaging for detection of silent myocardial ischemia

    International Nuclear Information System (INIS)

    Beller, G.A.

    1988-01-01

    Despite the widespread use of the exercise stress test in diagnosing asymptomatic myocardial ischemia, exercise radionuclide imaging remains useful for detecting silent ischemia in numerous patient populations, including those who are totally asymptomatic, those who have chronic stable angina, those who have recovered from an episode of unstable angina or an uncomplicated myocardial infarction, and those who have undergone angioplasty or received thrombolytic therapy. Studies show that thallium scintigraphy is more sensitive than exercise electrocardiography in detecting ischemia, i.e., in part, because perfusion defects occur more frequently than ST depression and before angina in the ischemic cascade. Thallium-201 scintigraphy can be performed to differentiate a true- from a false-positive exercise electrocardiographic test in patients with exercise-induced ST depression and no angina. The development of technetium-labeled isonitriles may improve the accuracy of myocardial perfusion imaging. 11 references

  20. Myocardial scintigraphy with thallium-201

    International Nuclear Information System (INIS)

    Schwaiger, M.; Silber, S.; Klein, U.; Rudolph, W.

    1980-01-01

    Thallium-201 myocardial scintigraphy is an important non-invasive method for assessment of coronary artery disease. Other applications of the method such as delineation of the right ventricular free wall in right ventricular overload, or the detection of hypertrophic cardiomyopathies or myocardial infiltrations are of subordinate importance. In heart disease such as congestive cardiomyopathy and mitral valve prolapse thallium-201 uptake defects have been described, the clinical implications of these findings, however, cannot be adequately interpreted at this time. Myocardial uptake of thallium-201 is an active process, dependent on and proportional to perfusion. Differentiation between myocardial ischemia and myocardial scar is based on the presence or absence of thallium-201 'redistribution'. That is, in the presence of acute reversible ischemia there is increased thallium-201 uptake in the post-ischemic phase in previously hypoperfused myocardium and, subsequently, equilibrium of the initially registered activity differences. 'Redistribution' has also been described in the resting scintigram of patients with severe coronary artery disease and chronic hypoperfusion. (orig.) [de

  1. Usefulness of multimodality imaging for detection of myocardial infarction in patients with advanced kidney failure: case report

    Energy Technology Data Exchange (ETDEWEB)

    Veras, Mariana Ferreira; Azevedo, Jader Cunha de; Gamarski, Moisés; Mesquita, Evandro Tinoco; Mesquita, Cláudio Tinoco, E-mail: fvmari@gmail.com [Hospital Procardíaco, Rio de Janeiro, RJ (Brazil); Alves, José Galvão [Centro Universitário de Volta Redonda, RJ (Brazil)

    2016-01-15

    The third universal definition of acute myocardial infarction (AMI) is based on the elevation of troponin in association with ischemic symptoms, electrocardiographic changes and imaging findings. In patients with chest pain, the diagnosis of AMI is performed by dosing serum markers of myocardial necrosis, particularly troponins, by means of changes in 12 - lead electrocardiogram (ECG) or by identifying changes in the contractile dynamics of the left ventricle to the transthoracic echocardiogram. In some cases, confounding factors may hamper the diagnosis, such as: (a) presence of previous changes in the baseline ECG, especially LBBB; (b) elevations of myocardial necrosis markers (MNM) resulting from situations other than AMI and; (c) old changes in contractility detected by transthoracic ECG. Serum cardiac troponin (Tn) is the most specific and most used MNM for the diagnosis of AMI. Nevertheless, in some situations troponin elevation may not be due to an AMI, as in cases of acute pulmonary embolism, acute pericarditis, severe heart failure, myocarditis, and sepsis and kidney failure. Patients with kidney failure have high probability of concurrent cardiovascular disease. Furthermore, the cross-reacting proteins interfering with skeletal muscle, analytical imprecision and interactions with the dialysis membrane may cause elevation of troponin in 7% to 17% of patients with kidney failure. When in doubt about diagnosis of AMI, {sup 99m}Technetium pyrophosphate myocardial scintigraphy ({sup 99m}Tc-PYP) stands out as a noninvasive method capable of identifying areas of myocardial necrosis, thus helping in the diagnosis of AMI. {sup 99m}Tc-labeled phosphonate agents undergo chemical absorption with calcium. A large influx of calcium occurs during the evolutionary process of AMI. The calcium flows into the intracellular space and myocardial concentration of {sup 99m}Tc-PYP follows such increase, with a maximum peak uptake about 48 to 72 hours after the acute event. The

  2. Mortality rate in type 2 myocardial infarction

    DEFF Research Database (Denmark)

    Saaby, Lotte; Poulsen, Tina Svenstrup; Diederichsen, Axel Cosmus Pyndt

    2014-01-01

    myocardial infarction, hypercholesterolemia, high p-creatinine, and diabetes mellitus. The multivariable-adjusted hazard ratio for type 2 myocardial infarction was 2.0 (95% confidence interval, 1.3-3.0). With shock as the only exception, mortality was independent of the triggering conditions leading to type....../119) in those with type 2 myocardial infarction and 26% (92/360) in those with type 1 myocardial infarction (P high age, prior myocardial infarction, type 2...... 2 myocardial infarction. CONCLUSIONS: Mortality in patients with type 2 myocardial infarction is high, reaching approximately 50% after 2 years. Further descriptive and survival studies are needed to improve the scientific evidence on which treatment of type 2 myocardial infarction is based....

  3. Sgarbossa criteria and acute myocardial infarction.

    Science.gov (United States)

    Alang, Neha; Bathina, Jaya; Kranis, Mark; Angelis, Dimitrios

    2010-01-01

    Diagnosis of acute ST-elevation myocardial infarction in the presence of left bundle branch block is difficult. present a case of acute myocardial infarction with LBBB diagnosed and treated using the Sgarbossa criteria.

  4. The endothelial glycocalyx protects against myocardial edema

    NARCIS (Netherlands)

    van den Berg, Bernard M.; Vink, Hans; Spaan, Jos A. E.

    2003-01-01

    Myocardial tissue edema attributable to increased microvascular fluid loss contributes to cardiac dysfunction after myocardial ischemia, cardiopulmonary bypass, hypertension, and sepsis. Recent studies suggest that carbohydrate structures on the luminal surface of microvascular endothelium are

  5. Efficient regeneration of NADPH in a 3-enzyme cascade reaction by in situ generation of glucose 6-phosphate from glucose and pyrophosphate

    NARCIS (Netherlands)

    Hartog, A.F.; van Herk, T.; Wever, R.

    2011-01-01

    We report here a promising method to regenerate NADPH (nicotinamide adenine dinucleotide phosphate) using the intermediate formation of glucose 6-phosphate (G6P) from glucose and pyrophosphate (PPi) catalyzed by the acid phosphatase from Shigella flexneri (PhoN-Sf). The G6P formed is used in turn by

  6. Effect of beam hardening on transmural myocardial perfusion quantification in myocardial CT imaging

    Science.gov (United States)

    Fahmi, Rachid; Eck, Brendan L.; Levi, Jacob; Fares, Anas; Wu, Hao; Vembar, Mani; Dhanantwari, Amar; Bezerra, Hiram G.; Wilson, David L.

    2016-03-01

    The detection of subendocardial ischemia exhibiting an abnormal transmural perfusion gradient (TPG) may help identify ischemic conditions due to micro-vascular dysfunction. We evaluated the effect of beam hardening (BH) artifacts on TPG quantification using myocardial CT perfusion (CTP). We used a prototype spectral detector CT scanner (Philips Healthcare) to acquire dynamic myocardial CTP scans in a porcine ischemia model with partial occlusion of the left anterior descending (LAD) coronary artery guided by pressure wire-derived fractional flow reserve (FFR) measurements. Conventional 120 kVp and 70 keV projection-based mono-energetic images were reconstructed from the same projection data and used to compute myocardial blood flow (MBF) using the Johnson-Wilson model. Under moderate LAD occlusion (FFR~0.7), we used three 5 mm short axis slices and divided the myocardium into three LAD segments and three remote segments. For each slice and each segment, we characterized TPG as the mean "endo-to-epi" transmural flow ratio (TFR). BH-induced hypoenhancement on the ischemic anterior wall at 120 kVp resulted in significantly lower mean TFR value as compared to the 70 keV TFR value (0.29+/-0.01 vs. 0.55+/-0.01 pvalues on segments moderately affected or unaffected by BH. In the entire ischemic LAD territory, 120 kVp mean endocardial flow was significantly reduced as compared to mean epicardial flow (15.80+/-10.98 vs. 40.85+/-23.44 ml/min/100g; p<1e-04). At 70 keV, BH was effectively minimized resulting in mean endocardial MBF of 40.85+/-15.3407 ml/min/100g vs. 74.09+/-5.07 ml/min/100g (p=0.0054) in the epicardium. We also found that BH artifact in the conventional 120 kVp images resulted in falsely reduced MBF measurements even under non-ischemic conditions.

  7. Myocardial area at risk after ST-elevation myocardial infarction measured with the late gadolinium enhancement after scar remodeling and T2-weighted cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Lønborg, Jacob; Engstrøm, Thomas; Mathiasen, Anders B

    2011-01-01

    To evaluate the myocardial area at risk (AAR) measured by the endocardial surface area (ESA) method on late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) when applied after scar remodeling (3 months after index infarction) compared to T2-weighted CMR imaging. One hundred...... and sixty nine patients with ST-elevation myocardial infarction, treated with primary percutaneous coronary intervention, underwent one CMR within 1 week after index treatment to determine the AAR with T2-weighted imaging and a second scan 3 months after to measure AAR with the ESA method...

  8. Myocardial area at risk after ST-elevation myocardial infarction measured with the late gadolinium enhancement after scar remodeling and T2-weighted cardiac magnetic resonance imaging

    DEFF Research Database (Denmark)

    Lønborg, Jacob; Engstrøm, Thomas; Mathiasen, Anders B

    2012-01-01

    To evaluate the myocardial area at risk (AAR) measured by the endocardial surface area (ESA) method on late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) when applied after scar remodeling (3 months after index infarction) compared to T2-weighted CMR imaging. One hundred...... and sixty nine patients with ST-elevation myocardial infarction, treated with primary percutaneous coronary intervention, underwent one CMR within 1 week after index treatment to determine the AAR with T2-weighted imaging and a second scan 3 months after to measure AAR with the ESA method...

  9. Myocardial infarction after near drowning.

    Science.gov (United States)

    Chen, Li-Bang; Lai, Yen-Chun; Chen, Chang-Chih; Chang, Wen-Han; Su, Yu-Jang

    2008-06-01

    During summer, near drowning is a common accident in Taiwan. It may lead to multiple organ damages in cases where severe hypothermia and hypoxemia occur. We present a case of myocardial infarction after near drowning. The patient was sent to our ED by the emergency medical services called by the witness. On arrival to our ED, hypothermia and hypoxemia overcame him. Endotracheal intubation and warm intravenous fluid were applied at once owing to drowsy consciousness, respiratory distress, and hypothermia. Electrocardiogram showed diffuse ST-segment elevation over the precordial leads V2-V6. The initial level of cardiac enzymes was within normal limit but elevated in troponin I on the second day after hospitalization. We presumed that the possibility of myocardial infarction resulted from near drowning-related hypoxemia. To our knowledge, this is the first case describing myocardial injury with electrocardiogram changes after near drowning.

  10. Dynamic CT myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Caruso, Damiano; Eid, Marwen; Schoepf, U. Joseph; Jin, Kwang Nam; Varga-Szemes, Akos; Tesche, Christian; Mangold, Stefanie

    2016-01-01

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  11. Dynamic CT myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncological and Pathological Sciences, University of Rome “Sapienza”, Latina (Italy); Eid, Marwen [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States); Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Mangold, Stefanie [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, Tuebingen (Germany); and others

    2016-10-15

    Highlights: • CT myocardial perfusion provides functional assessment of the myocardium. • CCTA is limited in determining the hemodynamic significance of coronary stenosis. • CT-MPI can accurately detect hemodynamically significant coronary artery stenosis. - Abstract: Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD.

  12. Uptake of myocardial imaging agents by rejected hearts

    International Nuclear Information System (INIS)

    Bergsland, J.; Carr, E.A.; Carroll, M.; Wright, J.W.; Feldman, M.J.; Massucci, J.; Bhayana, J.N.; Gona, J.M.

    1985-01-01

    Technetium 99 m pyrophosphate, Gallium 67 and Thallium 201 uptakes were measured in heterotopically transplanted rat hearts. Five days after transplantation, Technetium 99 m pyrophosphate, and Gallium 67 uptakes were significantly higher in allogeneic grafts than in syngeneic grafts. At an early stage of rejection (three days after transplantation), only Technetium 99 m pyrophosphate uptake in the left ventricle of allogeneic grafts showed a significant difference (p less than 0.04). At five days, Thallium 201 uptake was significantly lower in allo- than syngeneic grafts. There was a positive correlation between radionuclide uptake and histologic degree of rejection for Technetium 99 m pyrophosphate and Gallium 67 while Thallium 201 uptake correlated negatively. Analysis of variance revealed that hearts with no or minimal rejection had statistically different uptakes than hearts with mild to moderate rejection. These results suggest that uptake of imaging agents might be useful in the diagnosis of rejection of the transplanted heart

  13. Morphological aspects of myocardial bridges.

    Science.gov (United States)

    Lujinović, Almira; Kulenović, Amela; Kapur, Eldan; Gojak, Refet

    2013-11-01

    Although some myocardial bridges can be asymptomatic, their presence often causes coronary disease either through direct compression of the "tunnel" segment or through stimulation and accelerated development of atherosclerosis in the segment proximally to the myocardial bridge. The studied material contained 30 human hearts received from the Department of Anatomy. The hearts were preserved 3 to 5 days in 10% formalin solution. Thereafter, the fatty tissue was removed and arterial blood vessels prepared by careful dissection with special reference to the presence of the myocardial bridges. Length and thickness of the bridges were measured by the precise electronic caliper. The angle between the myocardial bridge fibre axis and other axis of the crossed blood vessel was measured by a goniometer. The presence of the bridges was confirmed in 53.33% of the researched material, most frequently (43.33%) above the anterior interventricular branch. The mean length of the bridges was 14.64 ± 9.03 mm and the mean thickness was 1.23 ± 1.32 mm. Myocardial bridge fibres pass over the descending blood vessel at the angle of 10-90 degrees. The results obtained on a limited sample suggest that the muscular index of myocardial bridge is the highest for bridges located on RIA, but that the difference is not significant in relation to bridges located on other branches. The results obtained suggest that bridges located on other branches, not only those on RIA, could have a great contractive power and, consequently, a great compressive force, which would be exerted on the wall of a crossed blood vessel.

  14. Different Causes of Death in Patients with Myocardial Infarction Type 1, Type 2, and Myocardial Injury.

    Science.gov (United States)

    Lambrecht, Sascha; Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S; Gerke, Oke; Hosbond, Susanne; Diederichsen, Axel C P; Thygesen, Kristian; Mickley, Hans

    2018-05-01

    Data outlining the mortality and the causes of death in patients with type 1 myocardial infarction, type 2 myocardial infarction, and those with myocardial injury are limited. During a 1-year period from January 2010 to January 2011, all hospitalized patients who had cardiac troponin I measured on clinical indication were prospectively studied. Patients with at least one cardiac troponin I value >30 ng/L underwent case ascertainment and individual evaluation by an experienced adjudication committee. Patients were classified as having type 1 myocardial infarction, type 2 myocardial infarction, or myocardial injury according to the criteria of the universal definition of myocardial infarction. Follow-up was ensured until December 31, 2014. Data on mortality and causes of death were obtained from the Danish Civil Registration System and the Danish Register of Causes of Death. Overall, 3762 consecutive patients were followed for a mean of 3.2 years (interquartile range 1.3-3.6 years). All-cause mortality differed significantly among categories: Type 1 myocardial infarction 31.7%, type 2 myocardial infarction 62.2%, myocardial injury 58.7%, and 22.2% in patients with nonelevated troponin values (log-rank test; P causes, vs 42.6% in patients with type 2 myocardial infarction (P = .015) and 41.2% in those with myocardial injury (P causes of death did not differ substantially between patients with type 2 myocardial infarction and those with myocardial injury. Patients with type 2 myocardial infarction and myocardial injury exhibit a significantly higher long-term mortality compared with patients with type 1 myocardial infarction . However, most patients with type 1 myocardial infarction die from cardiovascular causes in contrast to patients with type 2 myocardial infarction and myocardial injury, in whom noncardiovascular causes of death predominate. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. An autosampling differential scanning calorimeter instrument for studying molecular interactions.

    Science.gov (United States)

    Plotnikov, Valerian; Rochalski, Andrew; Brandts, Michael; Brandts, John F; Williston, Samuel; Frasca, Verna; Lin, Lung-Nan

    2002-11-01

    A new ultrasensitive differential scanning calorimeter (DSC) instrument is described, which utilizes autosampling for continuous operation. High scanning rates to 250 deg/h with rapid cooling and equilibration between scans facilitates higher sample throughput up to 50 samples during each 24 h of unattended operation. The instrument is suited for those pharmaceutical applications where higher throughput is important, such as screening drug candidates for binding constant or screening solution conditions for stability of liquid protein formulations. Results are presented on the binding of five different anionic inhibitors to ribonuclease A, which included cytidine 2'-monophosphate (2'CMP), 3'CMP, uridine 3'-monophosphate, pyrophosphate, and phosphate. Binding constants K(B) (or dissociation constants K(d)) are obtained from the shift in the transition temperature T(M) for ribonuclease thermal unfolding in the presence of ligand relative to the transition temperature in the absence of ligand. Measured binding constants ranged from 155 M(-1) (K(d) = 6.45 mM) for the weak-binding phosphate anion to 13100 M(-1) (K(d) = 76.3 microM) for the strongest binding ligand, 2'CMP. The DSC method for measuring binding constants can also be extended to ultratight interactions involving either ligand-protein or protein-protein binding.

  16. Prevention of lingual calculus formation with daily use of 6% H2O2/2% pyrophosphate whitening strips.

    Science.gov (United States)

    Farrell, S; Barker, M L; Gerlach, R W; Putt, M S; Milleman, J L

    2009-01-01

    This randomized controlled clinical trial was conducted to evaluate whether daily use of a hydrogen peroxide/ pyrophosphate-containing antitartar whitening strip might safely yield clinical reductions in post-prophylaxis calculus accumulation. A three-month, randomized controlled trial was conducted to compare calculus accumulation with a daily 6% hydrogen peroxide/pyrophosphate strip versus regular brushing. After an eight-week run-in phase to identify calculus formers, a prophylaxis was administered, and 77 subjects were randomly assigned to daily strip or brushing only groups. All subjects received an anticavity dentifrice (Crest Cavity Protection) and manual brush for use throughout the three-month study; for subjects assigned to the experimental group, strip application was once daily for five minutes on the facial and lingual surfaces of the mandibular teeth. Efficacy was measured as mm calculus (VMI) before prophylaxis and after six and 12 weeks of treatment, while safety was assessed from examination and interview. Subjects ranged in age from 21-87 years, with groups balanced (p > 0.26) on pertinent demographic and behavioral parameters, and pre-prophylaxis calculus baseline mean scores (16.0 mm). At Week 6, calculus accumulation was lower in the strip group, with adjusted mean (SE) lingual VMI of 12.0 (0.87) for the strip group and 17.0 (0.88) for the brushing control. At Week 12, calculus accumulation was lower in the strip group, with adjusted mean (SE) lingual VMI of 14.3 (0.85) for the strip group and 17.2 (0.86) for the brushing control. Treatments differed significantly (p calculus accumulation at both time points. A total of three subjects (8%) in the strip group and two subjects (5%) in the brushing control had mild oral irritation or tooth sensitivity during treatment; no one discontinued early due to an adverse event. Daily use of hydrogen peroxide whitening strips with pyrophosphate reduced calculus formation by up to 29% versus regular brushing

  17. Minimizing Patient-Specific Tracer Dose in Myocardial Perfusion Imaging Using CZT SPECT

    NARCIS (Netherlands)

    van Dijk, Joris David; Jager, Pieter L.; Ottervanger, Jan Paul; Slump, Cornelis H.; de Boer, Jaep; Oostdijk, Adrianus H.J.; van Dalen, Jorn A.

    Myocardial perfusion imaging (MPI) with SPECT is widely adopted in clinical practice but is associated with a relatively high radiation dose. The aim of this study was to determine the minimum product of tracer dose and scan time that will maintain diagnostic value for cadmium zinc telluride (CZT)

  18. Retrospective study of renal images on whole bone scanning

    International Nuclear Information System (INIS)

    Yanagisawa, Munetoshi; Machida, Toyohei; Miki, Makoto; Ohishi, Yukihiko; Ueda, Masataka

    1978-01-01

    One hundred and twenty-seven cases were surveyed by sup(99m)Tc-pyrophosphate at Jikei hospital. Renal images on whole-bone scanning were observed in all cases; 75% of all renal images were normal and 25% were abnormal. Thirteen percent of these abnormal images were symmetric and 87% were asymmetric. Four of the symmetric renal images were bilaterally bad. Three of the four bilaterally bad renal images involved prostate carcinomas with general metastases and the last involved serious bilateral hydronephrosis. The reason for the high percentage of asymmetric renal images was that the materials involved many urogenital cases. Asymmetric renal images other than the urogenital cases, were recognised in 8% of all cases. This percentage is consistent with Hattner's report. Unilateral abnormal renal images involved 8 hydronephrosis cases, 2 unilateral nonfunctioning kidneys and one malrotation kidney. Among the hydronephrosis cases, serious cases gave low uptake and mild cases gave high uptake. The reason for this phenomenon was, presumably, that there were differences in renal uptake, renal excretion and renal pelvic accumulation. In nine cases, one kidney was not visualized on whole-bone scanning, 8 of them involved nephrectomy and the remainining one unilateral nonfunctioning kidney. Six cases presented locally abnormal renal images on whole-bone scanning, three of them suffered renal cell carcinomas and the rest renal solitary cyst. Eighty-eight percent of the abnormal renal images agreed with IVP findings. The renal images of whole-bone scanning faithfully reflected the original renal lesion. Two cases of renal carcinoma and renal solitary cyst recognized on whole-bone scanning are presented, to indicate the usefulness of renal images on whole-bone scanning. (auth.)

  19. Wall motion abnormality of myocardial infarction

    International Nuclear Information System (INIS)

    Hayashi, Senji; Tsuda, Takashi; Ojima, Kenji

    1984-01-01

    By use of the gated blood pool scan, we divided the left ventricular LAO 45 image into 8 sections with the center of the volume as the basal point, and devised a method of quantitative evaluation of the regional wall motion from 2 aspects: 1) wall movement and 2) phase abnormality. To evaluate the wall movement, we obtained the following indeces from count curves of each section: 1) EF1=(end-diastolic count-end-systolic count)/ end-diastolic count, 2) EF2=(maximum count-minimum count)/maximum count, and 3) the difference of the two (EF2-EF1). As indeces of the phase abnormality, the mean value of phases of the pixels (phase characteristics) and the standard deviation (variation) of each section were calculated. Furthermore, the phase delay of each section was calculated as the difference from the earliest phase value of the 8 sections. Control values and standard deviation were obtained from 8 healthy controls. By this method, we analyzed 20 patients with old myocardial infarction. And following results were obtained: 1. Applying this method, we could evaluate the regional wall motion of the left ventricle more precisely, and we considered it would be useful clinically. 2. The abnormal regional wall motion of old myocardial infarction were classified into 4 typical forms as follows: 1) the wall movement decreased extremely. 2) the wall movement decreased, but no phase delay recognized. 3) the wall movement did not decrease, but phase delay was recognized. 4) the wall movement decreased, and phase delay was recognized. (author)

  20. Engineered protein degradation of farnesyl pyrophosphate synthase is an effective regulatory mechanism to increase monoterpene production in Saccharomyces cerevisiae

    DEFF Research Database (Denmark)

    Peng, Bingyin; Nielsen, Lars K.; Kampranis, Sotirios C

    2018-01-01

    Monoterpene production in Saccharomyces cerevisae requires the introduction of heterologous monoterpene synthases (MTSs). The endogenous farnesyl pyrosphosphate synthase (FPPS; Erg20p) competes with MTSs for the precursor geranyl pyrophosphate (GPP), which limits the production of monoterpenes. ERG......20 is an essential gene that cannot be deleted and transcriptional down-regulation of ERG20 has failed to improve monoterpene production. Here, we investigated an N-degron-dependent protein degradation strategy to down-regulate Erg20p activity. Degron tagging decreased GFP protein half......-life drastically to 1 h (degron K3K15) or 15 min (degrons KN113 and KN119). Degron tagging of ERG20 was therefore paired with a sterol responsive promoter to ensure sufficient metabolic flux to essential downstream sterols despite the severe destabilisation effect of degron tagging. A dual monoterpene...

  1. Pyrophosphate scintigraphy and other non-invasive methods in the detection of cardiac involvement in some systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F.; Bradna, P.; Pospisil, M.; Kubicek, J.; Vizda, J.; Kafka, P.; Palicka, V.; Mazurova, Y.

    1987-02-01

    Thirteen patients with systemic lupus erythematosus, 8 patients with polymyositis, and 6 patients with spondylitis ankylopoetica (Bechterew's disease) underwent clinical cardiologic examination and scintigraphy of the myocardium (/sup 99m/Tc-pyrophosphate), ECG, echocardiography, polygraphy, and their blood pressure was taken. The aim of the study was to ascertain how such a combination of non-invasive examinations can help in recognizing a cardiac involvement. In systemic lupus erythematosus cases one or more positive findings were revealed in 9 patients (69%), in 4 patients all examinations were negative (31%). Four patients (50%) with polymyosits had positive findings. In patients with spondylitis ankylopoetica positive findings occurred in 2 cases (33%). The study has shown that a combination of non-invasive cardiologic methods increases the probability of detecting cardiac involvement in systemic connective tissue diseases.

  2. Pyrophosphate scintigraphy and other non-invasive methods in the detection of cardiac involvement in some systemic connective tissue diseases

    Energy Technology Data Exchange (ETDEWEB)

    Duska, F; Bradna, P; Pospisil, M; Kubicek, J; Vizda, J; Kafka, P; Palicka, V; Mazurova, Y

    1987-02-01

    Thirteen patients with systemic lupus erythematosus, 8 patients with polymyositis, and 6 patients with spondylitis ankylopoetica (Bechterew's disease) underwent clinical cardiologic examination and scintigraphy of the myocardium (/sup 99m/Tc-pyrophosphate), ECG, echocardiography, polygraphy, and their blood pressure was taken. The aim of the study was to ascertain how such a combination of non-invasive examinations can help in recognizing a cardiac involvement. In systemic lupus erythematosus cases one or more positive findings were revealed in 9 patients (69%), in 4 patients all examinations were negative (31%). Four patients (50%) with polymyosits had positive findings. In patients with spondylitis ankylopoetica positive findings occurred in 2 cases (33%). The study has shown that a combination of non-invasive cardiologic methods increases the probability of detecting cardiac involvement in systemic connective tissue diseases.

  3. Contribution of sup(99m)Tc labelled sodium pyrophosphate bone scintigraphy to the diagnosis of bone metastases

    International Nuclear Information System (INIS)

    Remi, J.-P.

    1976-01-01

    Bone scintigraphy, by its ease of application and the use of short-lived isotopes, has revolutionised the conditions of bone metastase diagnosis. Scintigraphy possesses two advantages, the possibility it offers of exploring the whole skeleton at once and its extreme simplicity. This technique should therefore find its place at the very beginning of the bone examination, an attitude which also has dosimetric repercussions: a 'whole skeleton' examination delivers 170 mrad to the marrow, whereas spinal and pelvic X-rays deliver 325 mrad. Unfortunately the sup(99m)Tc-labelled sodium pyrophosphate bone scintigraphy is not specific to any given lesion. Diagnosis can only be improved by the appearance of tracers taken up specifically on the neoplasic tissue, as is already the case of 131 I for thyroid cancer metastases. Labelled bleomycine and 67 Ga have so far given disappointing results [fr

  4. Functional specialization of one copy of glutamine phosphoribosyl pyrophosphate amidotransferase in ureide production from symbiotically fixed nitrogen in Phaseolus vulgaris.

    Science.gov (United States)

    Coleto, Inmaculada; Trenas, Almudena T; Erban, Alexander; Kopka, Joachim; Pineda, Manuel; Alamillo, Josefa M

    2016-08-01

    Purines are essential molecules formed in a highly regulated pathway in all organisms. In tropical legumes, the nitrogen fixed in the nodules is used to generate ureides through the oxidation of de novo synthesized purines. Glutamine phosphoribosyl pyrophosphate amidotransferase (PRAT) catalyses the first committed step of de novo purine synthesis. In Phaseolus vulgaris there are three genes coding for PRAT. The three full-length sequences, which are intron-less genes, were cloned, and their expression levels were determined under conditions that affect the synthesis of purines. One of the three genes, PvPRAT3, is highly expressed in nodules and protein amount and enzymatic activity in these tissues correlate with nitrogen fixation activity. Inhibition of PvPRAT3 gene expression by RNAi-silencing and subsequent metabolomic analysis of the transformed roots shows that PvPRAT3 is essential for the synthesis of ureides in P. vulgaris nodules. © 2016 John Wiley & Sons Ltd.

  5. Anthranilate phosphoribosyltransferase: Binding determinants for 5'-phospho-alpha-d-ribosyl-1'-pyrophosphate (PRPP) and the implications for inhibitor design.

    Science.gov (United States)

    Evans, Genevieve L; Furkert, Daniel P; Abermil, Nacim; Kundu, Preeti; de Lange, Katrina M; Parker, Emily J; Brimble, Margaret A; Baker, Edward N; Lott, J Shaun

    2018-02-01

    Phosphoribosyltransferases (PRTs) bind 5'-phospho-α-d-ribosyl-1'-pyrophosphate (PRPP) and transfer its phosphoribosyl group (PRib) to specific nucleophiles. Anthranilate PRT (AnPRT) is a promiscuous PRT that can phosphoribosylate both anthranilate and alternative substrates, and is the only example of a type III PRT. Comparison of the PRPP binding mode in type I, II and III PRTs indicates that AnPRT does not bind PRPP, or nearby metals, in the same conformation as other PRTs. A structure with a stereoisomer of PRPP bound to AnPRT from Mycobacterium tuberculosis (Mtb) suggests a catalytic or post-catalytic state that links PRib movement to metal movement. Crystal structures of Mtb-AnPRT in complex with PRPP and with varying occupancies of the two metal binding sites, complemented by activity assay data, indicate that this type III PRT binds a single metal-coordinated species of PRPP, while an adjacent second metal site can be occupied due to a separate binding event. A series of compounds were synthesized that included a phosphonate group to probe PRPP binding site. Compounds containing a "bianthranilate"-like moiety are inhibitors with IC 50 values of 10-60μM, and K i values of 1.3-15μM. Structures of Mtb-AnPRT in complex with these compounds indicate that their phosphonate moieties are unable to mimic the binding modes of the PRib or pyrophosphate moieties of PRPP. The AnPRT structures presented herein indicated that PRPP binds a surface cleft and becomes enclosed due to re-positioning of two mobile loops. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Use of genomics to identify bacterial undecaprenyl pyrophosphate synthetase: cloning, expression, and characterization of the essential uppS gene.

    Science.gov (United States)

    Apfel, C M; Takács, B; Fountoulakis, M; Stieger, M; Keck, W

    1999-01-01

    The prenyltransferase undecaprenyl pyrophosphate synthetase (di-trans,poly-cis-decaprenylcistransferase; EC 2.5.1.31) was purified from the soluble fraction of Escherichia coli by TSK-DEAE, ceramic hydroxyapatite, TSK-ether, Superdex 200, and heparin-Actigel chromatography. The protein was labeled with the photolabile analogue of the farnesyl pyrophosphate analogue (E, E)-[1-3H]-(2-diazo-3-trifluoropropionyloxy)geranyl diphosphate and was detected on a sodium dodecyl sulfate-polyacrylamide gel as a protein with an apparent molecular mass of 29 kDa. This protein band was cut out from the gel, trypsin digested, and subjected to matrix-assisted laser desorption ionization mass spectrometric analysis. Comparison of the experimental data with computer-simulated trypsin digest data for all E. coli proteins yielded a single match with a protein of unassigned function (SWISS-PROT Q47675; YAES_ECOLI). Sequences with strong similarity indicative of homology to this protein were identified in 25 bacterial species, in Saccharomyces cerevisiae, and in Caenorhabditis elegans. The homologous genes (uppS) were cloned from E. coli, Haemophilus influenzae, and Streptococcus pneumoniae, expressed in E. coli as amino-terminal His-tagged fusion proteins, and purified over a Ni2+ affinity column. An untagged version of the E. coli uppS gene was also cloned and expressed, and the protein purified in two chromatographic steps. We were able to detect Upp synthetase activity for all purified enzymes. Further, biochemical characterization revealed no differences between the recombinant untagged E. coli Upp synthetase and the three His-tagged fusion proteins. All enzymes were absolutely Triton X-100 and MgCl2 dependent. With the use of a regulatable gene disruption system, we demonstrated that uppS is essential for growth in S. pneumoniae R6.

  7. Imaging techniques for myocardial inflammation

    International Nuclear Information System (INIS)

    O'Connell, J.B.; Henkin, R.E.; Robinson, J.A.

    1986-01-01

    Dilated cardiomyopathy (DC) represents a heterogeneous group of disorders which results in morbidity and mortality in young individuals. Recent evidence suggests that a subset of these patients have histologic evidence of myocarditis which is potentially treatable with immunosuppression. The identification of myocardial inflammation may therefore lead to development of therapeutic regimens designed to treat the cause rather than the effect of the myocardial disease. Ultimately, this may result in improvement in the abysmal prognosis of DC. The currently accepted technique for identification of active myocardial inflammation is endomyocardial biopsy. This technique is not perfect, however, since pathologic standards for the diagnosis of myocarditis have not been established. Furthermore, focal inflammation may give rise to sampling error. The inflammation-avid radioisotope gallium-67 citrate has been used as an adjunct to biopsy improving the yield of myocarditis from 7 percent to 36 percent. Serial imaging correlates well to biopsy results. Future studies are designed to study the applicability of lymphocyte labelling techniques to myocardial inflammatory disease

  8. Dosimetry in myocardial perfusion imaging

    Energy Technology Data Exchange (ETDEWEB)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C. [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares

    2011-07-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  9. Dosimetry in myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Toledo, Janine M.; Trindade, Bruno; Ribeiro, Tarcisio P.C.

    2011-01-01

    This paper conducts a dosimetric investigation on the myocardial perfusion image protocol, together with a literature reviewing, motivated by the significant statistic increasing on mortality, morbidity and disability associated with cardiovascular disease, surpassing infectious diseases. Nuclear Cardiology plays a role n the diagnostic functional evaluation of the heart and in the prognostic of patients with suspected or known cardiac ischemia. In the context of unstable myocardial ischemic syndrome, myocardial perfusion scintigraphy is a non-invasive procedure performed by administering a radiopharmaceutical targeted to the heart. As tool for this study are that the images obtained by thoracic angiotomography and abdominal aorta as a anatomic and functional information for model reproduction in SISCODES - System of Codes for Absorbed Dose Calculations based on Stochastic Methods. Data were manipulated in order to create a voxel computational model of the heart to be running in MCNP - Monte Carlo Neutron Particle Code. . It was assumed a homogeneous distribution of Tl-201 in cardiac muscle. Simulations of the transport of particles through the voxel and the interaction with the heart tissue were performed. As a result, the isodose curves in the heart model are displayed as well as the dose versus volume histogram of the heart muscle. We conclude that the present computational tools can generate doses distributed in myocardial perfusion. (author)

  10. Use of ultrafast computed tomography to quantitate regional myocardial perfusion: a preliminary report

    International Nuclear Information System (INIS)

    Rumberger, J.A.; Feiring, A.J.; Lipton, M.J.; Higgins, C.B.; Ell, S.R.; Marcus, M.L.

    1987-01-01

    The purpose of this study was to assess the potential for rapid acquisition computed axial tomography (Imatron C-100) to quantify regional myocardial perfusion. Myocardial and left ventricular cavity contrast clearance curves were constructed after injecting nonionic contrast (1 ml/kg over 2 to 3 seconds) into the inferior vena cava of six anesthetized, closed chest dogs (n = 14). Independent myocardial perfusion measurements were obtained by coincident injection of radiolabeled microspheres into the left atrium during control, intermediate and maximal myocardial vasodilation with adenosine (0.5 to 1.0 mg/kg per min, intravenously, respectively). At each flow state, 40 serial short-axis scans of the left ventricle were taken near end-diastole at the midpapillary muscle level. Contrast clearance curves were generated and analyzed from the left ventricular cavity and posterior papillary muscle regions after excluding contrast recirculation and minimizing partial volume effects. The area under the curve (gamma variate function) was determined for a region of interest placed within the left ventricular cavity. Characteristics of contrast clearance data from the posterior papillary muscle region that were evaluated included the peak myocardial opacification, area under the contrast clearance curve and a contrast clearance time defined by the full width/half maximal extent of the clearance curve. Myocardial perfusion (microspheres) ranged from 35 to 450 ml/100 g per min (mean 167 +/- 125)

  11. Myocardial imaging with cesium-130

    International Nuclear Information System (INIS)

    Harper, P.V.; Resnekov, L.; Stark, V.; Odeh, N.

    1984-01-01

    Recently comparative studies using nitrogen-13 ammonia and cesium-130 have shown strikingly different myocardial localization patterns in the same subjects with ischemic heart disease. Initial localization of ammonia, an avidly extracted agent, reflects the perfusion pattern in viable myocardial tissue. The myocardial localization of cesium ion, taking place more slowly over 15 to 20 minutes, is apparently much less flow dependent, causing uptake defects shown with ammonia to be largely filled in. Cesium thus appears to provide information on the extent of the viable myocardial mass, apart from perfusion. Cesium-130 (t1/2 30 m) decays by positron emission and electron capture. The whole body radiation absorbed dose, assuming uniform distribution, is 24 mrad/mCi. While abundant production of Cs-130 results from proton bombardment of natural xenon [Xe-130(rho,n)Cs-130] at 15 MeV, small amounts of Cs-129, -131, and -132 are also produced, and enriched Xe-130 is not available. Alternatively almost completely uncontaminated Cs-130 is available by alpha bombardment of natural I-127. Anhydrous sodium iodide is dissolved in acetone and a thin layer (≅20 mg per centimeter squared) is evaporated onto the gold plated tip of the internal target backing which is oscillated vertically to spread out the area upon which the beam is incident. The target surface is inclined 2.5 degrees to the beam giving a power density of about 400 watts per centimeter squared at 100μA which is adequately handled by water cooling. A 30-minute bombardment yields 4 to 5 mCi of Cs-130 which is dissolved directly from the target. This approach appears to offer a new and helpful method for evaluating ischemic heart disease by permitting evaluation of viable myocardial mass

  12. Myocardial protection in heart surgery.

    Science.gov (United States)

    Mentzer, Robert M

    2011-01-01

    One of the unmet clinical needs in heart surgery is the prevention of myocardial stunning and necrosis that occurs as a result of ischemia-reperfusion. Myocardial stunning, a frequent consequence after heart surgery, is characterized by a requirement for postoperative inotropic support despite a technically satisfactory heart operation. In high-risk patients with marginal cardiac reserve, stunning is a major cause of prolonged critical care and may be associated with as much as a 5-fold increase in mortality. In contrast, the frequency of myocardial necrosis (myocardial infarction [MI]) after cardiac surgery is less appreciated and its consequences are much more subtle. The consequences may not be apparent for months to years. While we now have a much better understanding of the molecular mechanisms underlying myocardial stunning and MI, we still have no effective way to prevent these complications, nor a consistently effective means to engage the well-studied endogenous mechanisms of cardioprotection. The failure to develop clinically effective interventions is multifactorial and can be attributed to reliance on findings obtained from subcellular and cellular studies, to drawing conclusions from preclinical large animal studies that have been conducted in a disease-free state, and to accepting less than robust surrogate markers of injury in phase II clinical trials. These factors also explain the disappointing failure to identify effective adjuvant therapy in the setting of percutaneous coronary revascularization for acute MI (AMI) and reperfusion injury. These issues have contributed to the disappointing outcomes of large and costly phase III trials, resulting in a lack of enthusiasm on the part of the pharmaceutical industry to engage in further drug development for this indication. The purpose of this review is to (1) define the scope of the clinical problem; (2) summarize the outcomes of selected phases II and III clinical trials; and (3) identify the gap that

  13. Myocardial ischemia in Kawasaki disease

    International Nuclear Information System (INIS)

    Fukuda, Tsuyoshi

    1993-01-01

    The detection of myocardial ischemia is essential for evaluation of patients with Kawasaki disease, especially who have had coronary artery lesions. To evaluate the clinical efficacy of Tl-201 single photon emission computed tomography (SPECT) after dipyridamole infusion (maximum dose 0.70 mg/kg) for detecting myocardial ischemia, 44 patients with Kawasaki disease aged 7.7±4.8 years at the study and 10 age matched controls were observed. In the Kawasaki disease group, significant coronary artery stenosis was observed in 14, coronary aneurysm without stenosis in 18, the regression of the coronary aneurysms in 2 and without coronary lesions in 10 patients. In 24 of 44 patients, treadmill exercise stress test was also performed at the same period. Myocardial ischemic changes were observed in 11 patients, all combined with significant coronary artery stenosis. The sensitivity of SPECT for detection of overall coronary stenosis was 79%, coronary that of treadmill exercise test was only 33% (p<0.001). Furthermore, among the patients having significant coronary stenosis, the severity score was significantly elevated in patients who had electrocardiographic abnormal Q wave compared to those without abnormal Q wave (51.0±38.8 versus 20.0±12.1, p<0.05). These data suggest that the pharmacological stress scintigraphy using dipyridamole injection provides not only the accurate detection but quantitative evaluation of myocardial ischemia in these patients. This noninvasive technique may become one of the most useful index for detection and follow-up of myocardial ischemia in Kawasaki disease. (author)

  14. Myocardial ischemia and angina pectoris

    International Nuclear Information System (INIS)

    Selwyn, A.P.; Fox, K.M.; Jonathan, A.; Lavender, P.; Watson, I.

    1981-01-01

    Ambulatory monitoring of ST segment changes was performed in 60 patients presenting with angina, positive ECG stress tests and coronary artery disease, 85% of ischemic ECG events were asymptomatic, 37% occurred with no increase in heart rate and 15% of episodes either lasted 20 minutes or more or fluctuated in severity. A controlled pilot study in ten patients showed depression. Radionuclide studies in 50 patients with angina and coronary artery disease have shown that stress (i.e., atrial pacing) produced different patterns of disturbed regional myocardial perfusion related to the patient's exercise capacity and eventually leading to a decrease in regional myocardial perfusion during the ischemic episode. ST segment depression appeared only after the decrease in regional myocardial perfusion. These findings combined with past research suggest that patients with angina and coronary artery disease can suffer frequent asymptomatic disturbances of the regional myocardial perfusion. The frequency of these episodes and the time course for the recovery of the metabolic consequences mean that segments of ventricular myocardium may be constantly abnormal. The relative importance of changes in coronary tone and malfunction of platelets in the diseased coronary tree needs to be examined in clinical research. Pilot studies of antiplatelet agents have shown a significant beneficial effect on episodes of ischemia occurring at night and those occurring without any increase in heart rate. The techniques and observations in these patients with coronary artery disease all suggest that acute transient regional myocardial ischemia is caused by a variety of mechnisms. Further research using objective methods is required to discover the causes of ischemia and to rationalize treatment. (orig./MG) [de

  15. Radioiodinated tracers for myocardial imaging

    International Nuclear Information System (INIS)

    Kulkarni, P.V.; Corbett, J.R.

    1990-01-01

    Recent advances in the efficient production of high purity radioiodine (123I) and new efficient radiolabeling techniques have allowed the development of new classes of cardiovascular radiopharmaceuticals. These include 123I-labeled fatty acids to assess myocardial metabolism, 123I-metaiodobenzylguanidine (MIBG) for myocardial neuronal activity, labeled monoclonal antibodies for myocardial necrosis, and labeled lipoproteins for receptor concentration. 123I-labeled fatty acids and MIBG are under clinical investigation with encouraging results. 123I- and 111In-labeled fragments of monoclonal antibodies to myosin have been used for imaging myocardial necrosis in humans. The development of radiotracers for imaging of cholinergic and adrenergic receptors is still in the experimental stage. Recent advances in imaging instrumentation and radiopharmaceuticals have resulted in cardiac imaging applications beyond blood pool ventriculography, perfusion, and infarct-avid imaging. Developments of radioiodine (123I)-labeled agents promise to play an important role in the assessment of myocardial metabolism, neuronal activity, and receptor concentration. The chemistry of iodine is well defined compared with that of 99mTc; therefore, iodine isotopes are well suited for labeling biologically important molecules. Among the iodine isotopes, 123I has nearly ideal nuclear properties for nuclear medical applications with a 13.3-hour half-life (T1/2) and 159 keV gamma emission (83%). Despite the nearly ideal chemical and nuclear properties of 123I, the widespread application of 123I-based radiopharmaceuticals in clinical practice has been limited by high production costs (123I is produced in a cyclotron), relatively limited availability, and the presence of undesirable radionuclidic impurities (124I, T1/2 = 4.2 days; 125I, T1/2 = 60 days; 126I, T1/2 = 13.1 days). 77 references

  16. Purification, molecular cloning, and expression of 2-hydroxyphytanoyl- CoA lyase, a peroxisomal thiamine pyrophosphate-dependent enzyme that catalyzes the carbon-carbon bond cleavage during à-oxidation of 3- methyl-branched fatty acids

    CERN Document Server

    Foulon, V; Croes, K; Waelkens, E

    1999-01-01

    Purification, molecular cloning, and expression of 2-hydroxyphytanoyl- CoA lyase, a peroxisomal thiamine pyrophosphate-dependent enzyme that catalyzes the carbon-carbon bond cleavage during à-oxidation of 3- methyl-branched fatty acids

  17. Study progress of cardiac MRI technology in assessment of myocardial viability after myocardial infarction

    International Nuclear Information System (INIS)

    Wang Jing; Zhang Hao

    2013-01-01

    Acute myocardial infarction (AMI) is one of the most common diseases that cause disability and death around the world. Correctly and effectively assessing the myocardial viability after myocardial infarction can reduce the disabled rate and mortality rate. At present, many methods could be used to assess myocardial viability. The cardiac magnetic resonance imaging (CMR) technology has a lot of advantages compared to other methods. In this paper, we reviewed the research progress of CMR in assessment of myocardial viability after myocardial infarction, and compared CMR with other technologies. (authors)

  18. Evaluation of left ventricular function in patient with old myocardial infarction by 201-thallium myocardial scintigraphy

    Energy Technology Data Exchange (ETDEWEB)

    Takahashi, Kanji; Shimohara, Yasuaki; Ito, Misao; Okada, Keisei [Kure Kyosai Hospital, Hiroshima (Japan); Kodama, Kazunori

    1984-08-01

    Correlation between the ratio of myocardial defect calculated by 201-thallium myocardial scintigraphy and the left ventricular ejection fraction (LVEF) obtained by gated blood pool scintigraphy and the maximum level of creatine phosphokinase (CPK) was studied in 70 patients with old myocardial infarction. There was a significant correlation between the defect ratio and the LVEF or CPK level in patients with anterior or septal myocardial infarction. In all patients with inferior myocardial infarction in whom no defect was seen, the LVEF was more than 40%. However, no distinct correlation between the defect ratio and the LVEF or CPK level was obtained in cases of inferior myocardial infarction.

  19. Value of Tl-201 in evaluating myocardial damage and ischemia in transplant patients

    International Nuclear Information System (INIS)

    Jazmati, B.; Tumeh, S.S.; Holman, L.B.

    1989-01-01

    Orthotopic heart transplant recipients suffer from graft rejection and accelerated coronary artery disease. The authors have evaluated 29 recipients of orthotopic heart transplants who had multiple biopsy-proved episodes of rejection and underwent annual T1-201 exercise myocardial scintigraphy and coronary angiography. Of 43 pairs of nuclear scans and coronary angiograms, 39 showed normal radiotracer uptake and coronary arteries. In four scans, there were ischemic changes, and in only one case was there significant two-vessel coronary artery disease. The nuclear scans correlated with the coronary angiograms in 93% of the cases. The authors conclude that T1-201 myocardial scintigraphy is insensitive in the early detection of graft rejection and can reliably rule out significant coronary artery disease in transplant recipients

  20. Prognostic importance of silent myocardial ischemia detected by intravenous dipyridamole thallium myocardial imaging in asymptomatic patients with coronary artery disease

    International Nuclear Information System (INIS)

    Younis, L.T.; Byers, S.; Shaw, L.; Barth, G.; Goodgold, H.; Chaitman, B.R.

    1989-01-01

    One hundred seven asymptomatic patients who underwent intravenous dipyridamole thallium imaging were evaluated to determine prognostic indicators of subsequent cardiac events over an average follow-up period of 14 +/- 10 months. Univariate analysis of 18 clinical, scintigraphic and angiographic variables revealed that a reversible thallium defect, a combined fixed and reversible thallium defect, number of segmental thallium defects and extent of coronary artery disease were significant predictors of subsequent cardiac events. Of the 13 patients who died or had a nonfatal infarction, 12 had a reversible thallium defect. Stepwise logistic regression analysis selected a reversible thallium defect as the only significant predictor of cardiac events. When death or myocardial infarction was the outcome variable, a combined fixed and reversible thallium defect was the only predictor of outcome. In patients without previous myocardial infarction, the cardiac event rate was significantly greater in those with an abnormal versus normal thallium scan (55% versus 12%, p less than 0.001). Thus, intravenous dipyridamole thallium scintigraphy is a useful noninvasive test to risk stratify asymptomatic patients with coronary artery disease. A reversible thallium defect most likely indicates silent myocardial ischemia in a sizable fraction of patients in this clinical subset and is associated with an unfavorable prognosis

  1. Radiopharmaceutical scanning agents

    International Nuclear Information System (INIS)

    1976-01-01

    This invention is directed to dispersions useful in preparing radiopharmaceutical scanning agents, to technetium labelled dispersions, to methods for preparing such dispersions and to their use as scanning agents

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Scan and Uptake Thyroid scan and uptake uses small amounts of radioactive materials called radiotracers, a special ... is a branch of medical imaging that uses small amounts of radioactive material to diagnose and determine ...

  3. Nuclear Heart Scan

    Science.gov (United States)

    ... Home / Nuclear Heart Scan Nuclear Heart Scan Also known as Nuclear Stress Test , ... Learn More Connect With Us Contact Us Directly Policies Privacy Policy Freedom of Information Act (FOIA) Accessibility ...

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... of page What will I experience during and after the procedure? Most thyroid scan and thyroid uptake ... you otherwise, you may resume your normal activities after your nuclear medicine scan. If any special instructions ...

  5. RBC nuclear scan

    Science.gov (United States)

    ... page: //medlineplus.gov/ency/article/003835.htm RBC nuclear scan To use the sharing features on this page, please enable JavaScript. An RBC nuclear scan uses small amounts of radioactive material to ...

  6. Nifedipine and thallium-201 myocardial perfusion in progressive systemic sclerosis

    International Nuclear Information System (INIS)

    Kahan, A.; Devaux, J.Y.; Amor, B.

    1986-01-01

    Heart disease in patients with progressive systemic sclerosis may be due in part to myocardial ischemia caused by a disturbance of the coronary microcirculation. To determine whether abnormalities of myocardial perfusion in this disorder are potentially reversible, we evaluated the effect of the coronary vasodilator nifedipine on myocardial perfusion assessed by thallium-201 scanning in 20 patients. Thallium-201 single-photon-emission computerized tomography was performed under control conditions and 90 minutes after 20 mg of oral nifedipine. The mean (+/- SD) number of left ventricular segments with perfusion defects decreased from 5.3 +/- 2.0 to 3.3 +/- 2.2 after nifedipine (P = 0.0003). Perfusion abnormalities were quantified by a perfusion score (0 to 2.0) assigned to each left ventricular segment and by a global perfusion score (0 to 18) for the entire left ventricle. The mean perfusion score in segments with resting defects increased from 0.97 +/- 0.24 to 1.26 +/- 0.44 after nifedipine (P less than 0.00001). The mean global perfusion score increased from 11.2 +/- 1.7 to 12.8 +/- 2.4 after nifedipine (P = 0.003). The global perfusion score increased by at least 2.0 in 10 patients and decreased by at least 2.0 in only 1. These observations reveal short-term improvement in thallium-201 myocardial perfusion with nifedipine in patients with progressive systemic sclerosis. The results are consistent with a potentially reversible abnormality of coronary vasomotion in this disorder, but the long-term therapeutic effects of nifedipine remain to be determined

  7. Myocardial perfusion modeling using MRI

    DEFF Research Database (Denmark)

    Larsson, H B; Fritz-Hansen, T; Rostrup, Egill

    1996-01-01

    In the present study, it is shown that it is possible to quantify myocardial perfusion using magnetic resonance imaging in combination with gadolinium diethylenetriaminopentaacetic acid (Gd-DTPA). Previously, a simple model and method for measuring myocardial perfusion using an inversion recovery...... turbo-FLASH (fast low-angle shot) sequence and Gd-DTPA has been presented. Here, an extension of the model is presented taking into account fast and slow water exchange between the compartments, enabling the calculation of the unidirectional influx constant (Ki) for Gd-DTPA, the distribution volume...... of Gd-DTPA (lambda), the vascular blood volume (Vb), and the time delay through the coronary arteries (delta T). The model was evaluated by computer simulation and used on experimental results from seven healthy subjects. The results in the healthy volunteers for a region of interest placed...

  8. Scanning gamma camera

    International Nuclear Information System (INIS)

    Engdahl, L.W.; Batter, J.F. Jr.; Stout, K.J.

    1977-01-01

    A scanning system for a gamma camera providing for the overlapping of adjacent scan paths is described. A collimator mask having tapered edges provides for a graduated reduction in intensity of radiation received by a detector thereof, the reduction in intensity being graduated in a direction normal to the scanning path to provide a blending of images of adjacent scan paths. 31 claims, 15 figures

  9. Functional tests for myocardial ischemia

    International Nuclear Information System (INIS)

    Levinson, J.R.; Guiney, T.E.; Boucher, C.A.

    1991-01-01

    Functional tests for myocardial ischemia are numerous. Most depend upon a combination of either exercise or pharmacologic intervention with analysis of the electrocardiogram, of regional perfusion with radionuclide imaging, or of regional wall motion with radionuclide imaging or echocardiography. While each test has unique features, especially at the research level, they are generally quite similar in clinical practice, so the clinician is advised to concentrate on one or two in which local expertise is high.22 references

  10. Site-specific transition metal occupation in multicomponent pyrophosphate for improved electrochemical and thermal properties in lithium battery cathodes: a combined experimental and theoretical study.

    Science.gov (United States)

    Shakoor, Rana A; Kim, Heejin; Cho, Woosuk; Lim, Soo Yeon; Song, Hannah; Lee, Jung Woo; Kang, Jeung Ku; Kim, Yong-Tae; Jung, Yousung; Choi, Jang Wook

    2012-07-18

    As an attempt to develop lithium ion batteries with excellent performance, which is desirable for a variety of applications including mobile electronics, electrical vehicles, and utility grids, the battery community has continuously pursued cathode materials that function at higher potentials with efficient kinetics for lithium insertion and extraction. By employing both experimental and theoretical tools, herein we report multicomponent pyrophosphate (Li(2)MP(2)O(7), M = Fe(1/3)Mn(1/3)Co(1/3)) cathode materials with novel and advantageous properties as compared to the single-component analogues and other multicomponent polyanions. Li(2)Fe(1/3)Mn(1/3)Co(1/3)P(2)O(7) is formed on the basis of a solid solution among the three individual transition-metal-based pyrophosphates. The unique crystal structure of pyrophosphate and the first principles calculations show that different transition metals have a tendency to preferentially occupy either octahedral or pyramidal sites, and this site-specific transition metal occupation leads to significant improvements in various battery properties: a single-phase mode for Li insertion/extraction, improved cell potentials for Fe(2+)/Fe(3+) (raised by 0.18 eV) and Co(2+)/Co(3+) (lowered by 0.26 eV), and increased activity for Mn(2+)/Mn(3+) with significantly reduced overpotential. We reveal that the favorable energy of transition metal mixing and the sequential redox reaction for each TM element with a sufficient redox gap is the underlying physical reason for the preferential single-phase mode of Li intercalation/deintercalation reaction in pyrophosphate, a general concept that can be applied to other multicomponent systems. Furthermore, an extremely small volume change of ~0.7% between the fully charged and discharged states and the significantly enhanced thermal stability are observed for the present material, the effects unseen in previous multicomponent battery materials.

  11. {8-14C}-Adenine and {1-14C}-isopentenyl pyrophosphate - precursors for root-produced cytokinins in the tomato (Lycopersicon esculentum mill.)

    International Nuclear Information System (INIS)

    Dickinson, J.R.

    1985-01-01

    Following the detection of reasonable levels of biologically active cytokinin-like compounds in one-month-old tomato plants, the possible involvement of {8- 14 C}-adenine and {1- 14 C}-isopentenyl pyrophosphate in the biosynthetic pathway leading to an accumulation of free zeatin derivatives, was studied. Intact tomato plants were used for a time-course study involving the uptake of {8- 14 C}-adenine and the tentative identification of compounds into which the 14 C became incorporated. Using high performance liquid chromatography, radioactive trans-zeatin was identified as being present in the Dowex 50 root extract. The 12-hour time interval was used and the roots of the tomato plants were immersed in a more heavily radiolabelled medium. Modified separation techniques were used to achieve enhanced radioactivity recovery rates. This experiment demonstrated the presence of relatively high levels of tentatively identified radioactive zeatin in the Dowex 50 root and stem extracts. Radioactivity in the aqueous extracts was found not to be contributed by cytokinin nucleotides. A final experiment was carried out using decapitated root systems to determine if the root tissue alone could be implicated in the synthesis of cytokinins. Decapitated tomato root systems were supplied with either {8- 14 C}-adenine or {1- 14 C}-isopentenyl pyrophosphate. The ratio of incorporation of {1- 14 C}-isopentenyl pyrophosphate into identified cytokinins was higher than for {8- 14 C}-adenine. It was concluded that both adenine and isopentenyl pyrophosphate are involved in the biosynthetic pathway leading to an accumulation of free zeatin derivatives in tomato roots

  12. Cardiac MRI for myocardial ischemia.

    LENUS (Irish Health Repository)

    Daly, Caroline

    2013-01-01

    Proper assessment of the physiologic impact of coronary artery stenosis on the LV myocardium can affect patient prognosis and treatment decisions. Cardiac magnetic resonance imaging (CMR) assesses myocardial perfusion by imaging the myocardium during a first-pass transit of an intravenous gadolinium bolus, with spatial and temporal resolution substantially higher than nuclear myocardial perfusion imaging. Coupled with late gadolinium enhancement (LGE) imaging for infarction during the same imaging session, CMR with vasodilating stress perfusion imaging can qualitatively and quantitatively assess the myocardial extent of hypoperfusion from coronary stenosis independent of infarcted myocardium. This approach has been validated experimentally, and multiple clinical trials have established its diagnostic robustness when compared to stress single-photon emission computed tomography. In specialized centers, dobutamine stress CMR has been shown to have incremental diagnostic value above stress echocardiography due to its high imaging quality and ability to image the heart with no restriction of imaging window. This paper reviews the technical aspects, diagnostic utility, prognostic values, challenges to clinical adaptation, and future developments of stress CMR imaging.

  13. Paraplegia after myocardial revascularization. Case report.

    Science.gov (United States)

    Nigro Neto, Caetano; Iza, Milton Patricio Chango; Tardelli, Maria Angela

    2010-01-01

    Developments in anesthesiology have improved safety indices. Several techniques and agents are used to control the hemodynamic response and minimize adverse effects triggered by surgical stimuli in patients undergoing cardiac procedures. This is a 70 years old male patient, 1.74 m, 75 kg, ASA III, and NYHA II. The patient had controlled dyslipedemia, type II diabetes mellitus, and hypertension; history of smoking, peripheral vascular disease, and myocardial infarction 20 years ago. The patient underwent revascularization with the left internal mammary artery and saphenous grafts with extracorporeal circulation with intermittent clamping of the aorta. During the first 24 hours in the ICU, the patient developed hemodynamic instability, sudden hypotension, and atrial fibrillation. Twenty-six hours after the end of the surgery, the patient was awake, hemodynamically stable, and with good respiratory dynamics, being extubated. The patient was talkative and oriented, but immobile and negative reflexes in the lower limbs. Neurological evaluation showed: cranial nerves without changes, no complaints of pain below the hips, preserved superficial and deep sensitivity, adequate distal perfusion without edema, and flaccid paraplegia below T8. The echocardiogram did not show any changes. CT scan of the lumbosacral spine was negative for compressive mass in the epidural space or adjacent to it. Anterior spinal artery syndrome should be considered in procedures with manipulation of the aorta. Prevention, especially in patients at risk, is necessary. Computed tomography, for the differential diagnosis, and MRI, to localize the lesion, are important.

  14. Precipitation of PEG/Carboxyl-Modified Gold Nanoparticles with Magnesium Pyrophosphate: A New Platform for Real-Time Monitoring of Loop-Mediated Isothermal Amplification.

    Science.gov (United States)

    Qin, Ailin; Fu, Lok Tin; Wong, Jacky K F; Chau, Li Yin; Yip, Shea Ping; Lee, Thomas M H

    2017-03-29

    Gold nanoparticles have proven to be promising for decentralized nucleic acid testing by virtue of their simple visual readout and absorbance-based quantification. A major challenge toward their practical application is to achieve ultrasensitive detection without compromising simplicity. The conventional strategy of thermocycling amplification is unfavorable (because of both instrumentation and preparation of thermostable oligonucleotide-modified gold nanoparticle probes). Herein, on the basis of a previously unreported co-precipitation phenomenon between thiolated poly(ethylene glycol)/11-mercaptoundecanoic acid co-modified gold nanoparticles and magnesium pyrophosphate crystals (an isothermal DNA amplification reaction byproduct), a new ultrasensitive and simple DNA assay platform is developed. The binding mechanism underlying the co-precipitation phenomenon is found to be caused by the complexation of carboxyl and pyrophosphate with free magnesium ions. Remarkably, poly(ethylene glycol) does not hinder the binding and effectively stabilizes gold nanoparticles against magnesium ion-induced aggregation (without pyrophosphate). In fact, a similar phenomenon is observed in other poly(ethylene glycol)- and carboxyl-containing nanomaterials. When the gold nanoparticle probe is incorporated into a loop-mediated isothermal amplification reaction, it remains as a red dispersion for a negative sample (in the absence of a target DNA sequence) but appears as a red precipitate for a positive sample (in the presence of a target). This results in a first-of-its-kind gold nanoparticle-based DNA assay platform with isothermal amplification and real-time monitoring capabilities.

  15. Usefulness of contrast enhanced cardiac computed tomography in myocardial infarction

    International Nuclear Information System (INIS)

    Morooka, Nobuhiro; Yamada, Zenju; Watanabe, Shigeru

    1982-01-01

    Contrast enhanced cardiac computed tomography (CECT) was performed in 33 patients with transmural myocardial infarction. The anterior wall thickness assessed by CECT was well correlated with that by left ventriculography in RAO projection. When the septal wall thickness was compared between ECG gated and non-gated CECT images, the septal wall thickness by non-gated CECT showed a close coincidence with the diastolic wall thickness by ECG gated CECT. In all patients, the thickness of the septal, anterior and postero-lateral walls was measured. The mean wall thickness in patients of antero-septal infarction was 9.0 +- 1.9 mm for the septal wall, 6.3 +- 1.3 mm for the anterior wall, and 10.0 +- 2.1 mm for the postero-lateral wall. In patients of infero-lateral infarction, the mean wall thickness was 12.2 +- 1.7 mm for the septal wall, 10.8 +- 1.6 mm for the anterior wall and 8.9 +- 1.2 mm for the postero-lateral wall. A filling defect was revealed in the infarcted area when CECT was performed in patients with acute myocardial infarction within 1 week from the onset, and late enhancement was demonstrated by plain CT performed 10 min later. Left ventricular aneurysms were noted in 16 of 23 patients of anteroseptal infarction, and 8 of these 16 had mural thrombi in the left ventricle. Coronary artery calcification was found in 11 of 33 myocardial infarction patients. In patients with aortocoronary bypass graft, the sequential scan (dynamic scan) was shown to be a useful non-invasive method because it showed whether the graft was patent or not. (J.P.N.)

  16. Diffuse Myocardial Uptake of 99mTc-HDP in Multiple Myeloma

    International Nuclear Information System (INIS)

    Demirel, Koray; Sadic, Murat; Korkmaz, Meliha; Comak, Aylin; Atilgan, Hasan Ikbal; Koca, Goekhan

    2013-01-01

    Soft tissue uptake is a rare finding in bone scintigraphy, with an incidence of 2%. Although the mechanism has not yet been fully clarified, several causes have been reported for this unusual uptake pattern. This paper presents a case of diffuse myocardial accumulation of technetium-99m hydroxymethylene diphosphonate ( 99m Tc-HDP) without either solid/visceral organ or soft tissue with multiple myeloma (MM) in skeletal scintigraphy. A 93-year-old man with hypertension and chronic heart failure for 14 years underwent bone scanning due to a 2-month history of back pain within a 1-year period of MM. Three hours later, 99m Tc-HDP late static images showed diffuse myocardial radiotracer accumulation and there were no other sites of abnormal soft tissue or visceral uptake. Myocardial accumulation had disappeared on 24-h delayed static images. This accumulation was thought to be related with AL-type amyloidosis associated with MM

  17. Diffuse Myocardial Uptake of {sup 99m}Tc-HDP in Multiple Myeloma

    Energy Technology Data Exchange (ETDEWEB)

    Demirel, Koray; Sadic, Murat; Korkmaz, Meliha; Comak, Aylin; Atilgan, Hasan Ikbal; Koca, Goekhan [Ministry of Health Ankara Training and Research Hospital, Ankara (Turkmenistan)

    2013-09-15

    Soft tissue uptake is a rare finding in bone scintigraphy, with an incidence of 2%. Although the mechanism has not yet been fully clarified, several causes have been reported for this unusual uptake pattern. This paper presents a case of diffuse myocardial accumulation of technetium-99m hydroxymethylene diphosphonate ({sup 99m}Tc-HDP) without either solid/visceral organ or soft tissue with multiple myeloma (MM) in skeletal scintigraphy. A 93-year-old man with hypertension and chronic heart failure for 14 years underwent bone scanning due to a 2-month history of back pain within a 1-year period of MM. Three hours later, {sup 99m}Tc-HDP late static images showed diffuse myocardial radiotracer accumulation and there were no other sites of abnormal soft tissue or visceral uptake. Myocardial accumulation had disappeared on 24-h delayed static images. This accumulation was thought to be related with AL-type amyloidosis associated with MM.

  18. Prospective evaluation of stress myocardial perfusion imaging for pre-operative cardiac risk assessment

    International Nuclear Information System (INIS)

    Byrne, A.J.; Rowe, C.C.; Flannery, G.

    2002-01-01

    Full text: A prospective evaluation of patients who underwent stress myocardial perfusion imaging (MPI) to assess preoperative cardiac risk was undertaken. At the time of the scan patients were classified into 4 Clinical Risk groups (CR) based on known clinical data. On completion of the scan, the patient was then categorised into 4 Scan based Risk groups (SR), incorporating size of perfusion deficit, single versus multi-vessel disease and ejection fraction. Surgery at Austin and Repatriation Medical Centre within 6 months of scan and complications were identified using the hospital medical database. Major early cardiac events coded were death (cardiac related), myocardial infarction, unstable angina, acute pulmonary oedema, cardiac arrest, and urgent revascularisation. 208 patients have reached 6 months post-MPI scan. Of these 119 (57%) were identified as having surgery. Of the Scan Risk groups, 63% of normal, 57% of increased, and 47% of high and very high groups have had surgery. An abnormal scan is associated with a three-fold risk of cardiac complication (3.5% vs 11.3%). This is lower than most previous reports and may be due to higher representation of low risk surgical procedures (14% in this series), improved peri-operative care and/or the test result influence on management (suggested by decreasing surgical rate as SR estimate rose). Copyright (2002) The Australian and New Zealand Society of Nuclear Medicine Inc

  19. Dipyridamole-thallium-201 scintigraphy in the prediction of future cardiac events after acute myocardial infarction

    International Nuclear Information System (INIS)

    Leppo, J.A.; O'Brien, J.; Rothendler, J.A.; Getchell, J.D.; Lee, V.W.

    1984-01-01

    To evaluate the safety and usefulness of serial thallium scanning immediately after intravenous dipyridamole, we studied 51 patients recovering from acute myocardial infarction. Eight patients experienced angina during the procedure, but there were no serious complications. Patients were followed for a mean period of 19 months after hospital discharge. Eleven of 12 patients who died during follow-up or had another infarction had shown transient defects (redistribution) on their predischarge scan, as had 22 of the 24 patients who needed readmission for management of angina. Among all the other clinical or scintigraphic criteria tested, the presence of redistribution on the dipyridamole-thallium scan was the only significant predictor of these serious cardiac events. Twenty-six patients were also given a submaximal exercise test before discharge, of whom 13 subsequently had serious cardiac events. The exercise test had been positive in only 6 of these 13 patients, whereas the dipyridamole-thallium scan had shown a redistribution pattern in 12 (P less than 0.001). We conclude from this preliminary study that dipyridamole-thallium scintigraphy after myocardial infraction is relatively safe. It appears to be a more sensitive predictor of subsequent cardiac events than a submaximal exercise test and may therefore prove useful in evaluating patients after recovery from a myocardial infarction

  20. Noninvasive quantification of myocardial perfusion heterogeneity by Markovian analysis in SPECT nuclear imaging

    International Nuclear Information System (INIS)

    Pons, G.

    2011-01-01

    Cardiovascular diseases are the leading cause of mortality worldwide, and third of these deaths are caused by coronary artery disease and rupture of vulnerable atherosclerotic plaques. The heterogeneous alteration of the coronary microcirculation is an early phenomenon associated with many cardiovascular risk factors that can strongly predict the subsequent development of coronary artery disease, and lead to the appearance of myocardial perfusion heterogeneity. Nuclear medicine allows the study of myocardial perfusion in clinical routine through scintigraphic scans performed after injection of a radioactive tracer of coronary blood flow. Analysis of scintigraphic perfusion images currently allows the detection of myocardial ischemia, but the ability of the technique to measure the perfusion heterogeneity in apparently normally perfused areas is unknown. The first part of this thesis focuses on a retrospective clinical study to determine the feasibility of myocardial perfusion heterogeneity quantification measured by Thallium-201 single photon emission computed tomography (SPECT) in diabetic patients compared with healthy subjects. The clinical study has demonstrated the ability of routine thallium-201 SPECT imaging to quantify greater myocardial perfusion heterogeneity in diabetic patients compared with normal subjects. The second part of this thesis tests the hypothesis that the myocardial perfusion heterogeneity could be quantified in small animal SPECT imaging by Thallium-201 and/or Technetium-99m-MIBI in an experimental study using two animal models of diabetes, and is correlated with histological changes. The lack of difference in myocardial perfusion heterogeneity between control and diabetic animals suggests that animal models are poorly suited, or that the technology currently available does not seem satisfactory to obtain similar results as the clinical study. (author)

  1. The value of myocardial perfusion imaging in differentiating between idiopathic dilated cardiomyopathy from the ischemic form

    International Nuclear Information System (INIS)

    Fad, A.; Emami, F.; Eftekhari, M.; Saghari, M.; Fallahi, B.; Beiki, D.; Tkavar, A.

    2004-01-01

    Introduction: differentiating between ischemic cardiomyopathy and idiopathic dilated cardiomyopathy is important as coronary revascularization can improve prognosis in the ischemic subgroup. Due to inherent problems of coronary angiography in patients with depressed ejection fraction introducing a noninvasive tool to diagnose those who will benefit from angiography seems to be rewarding. We examined usefulness of myocardial perfusion scan in this group of patients. Materials and methods: study was performed on 64 patients (62 male and 2 female) aged 57.1 ± 6.7 y (mean ± SD) all with dilation of the left ventricular cavity and ejection fraction less than 40 % by echocardiography. Myocardial perfusion scan was performed in stress and rest phases. All the patients had coronary angiography which was used as the gold standard test. On each set of images, heart was arbitrary divided into 17 segments and perfusion abnormality in each segment was scored by a 5 grade scoring system (0-4). Summed stress Score was used as the scan criteria to differentiate dilated ischemic from idiopathic cardiomyopathy. Scores more than 17 were considered ischemic, and less than that, idiopathic. Results were compared with angiography. Results: from total 40 cases of ischemic cardiomyopathy (proved by angiography) 39 were correctly diagnosed by scan and only one case was mis categorized as idiopathic dilated cardiomyopathy . All 24 cases of idiopathic dilated cardiomyopathy were correctly diagnosed by scintigraphy. Sensitivity, specificity, positive predictive value, and negative predictive value of myocardial perfusion imaging for discrimination between ischemic and idiopathic dilated cardiomyopathy were 97.5 %, 100 %, 100 %, and 96 % respectively. Conclusion: Considering excellent accuracy of myocardial perfusion scan with scoring system in discrimination of ischemic dilated cardiomyopathy from idiopathic cardiomyopathy, this noninvasive test could be considered the main diagnostic test

  2. Screening for silent myocardial ischemia caseof diabetics : interest of myocardial perfusion scintigraphy

    International Nuclear Information System (INIS)

    Bahri, Haifa

    2007-01-01

    Silent myocardial ischemia is a major cause of morbidity and mortality in diabetic patients. Its diagnosis by noninvasive means such as myocardial SPECT would improve the management of these patients. The purpose of this study is to assess the frequency of silent myocardial ischemia in asymptomatic diabetics and their evolution. As a result, the myocardial SPECT is a reliable tool for screening for silent myocardial ischemia in diabetic patients. Its prognostic value allows to stratify the cardiac risk and guide therapeutic management. Its integration into a screening strategy in Tunisia seems limited by its low availability and cost. The latter could be reduced by better patient selection.

  3. Method of quantification of bone scintigraphy using technetium labelled stannous pyrophosphate. Results concerning 882 whole-body scintigraphy

    International Nuclear Information System (INIS)

    Chedeville, Rene.

    1976-01-01

    Considerable progress was made in isotope bone imaging with strontium 85 after the principle of quantification was introduced by Rosenthall in 1965. In 1971, Subramanian and McAffee reported that excellent visualization could be obtained with polyphosphates labelled with sup(99m)Tc. In the present study, imaging was performed 4 hours after injection of sup(99m)Tc pyrophosphate. An Elscint dual head wole body scanner and a VDP 2 off-line calculator were used. Counts were collected over selected regions of interest, each measuring 4.5 x 3.5 cm, and over the whole body. After checking reproducibility by double counting (SD of the mean = 15%), two methods of quantification were studied, the counts being expressed as: the ratio of the number of counts in the bone segment to the number of counts in the knee, the ratio of the number of counts in the bone segment/the number of counts in the whole body. In these operations, the whole body count was multiplied by 2.10 -3 in order to have a ratio whole body count.2.10 -3 /knee = 1. The ratios calculated from the different bone diseases under study were then compared [fr

  4. Calcification in calcium pyrophosphate dihydrate (CPPD) crystalline deposits in the knee: anatomic, radiographic, MR imaging, and histologic study in cadavers

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, M.; Chung, C.B.; Lima, J.E. de; Trudell, D. [Department of Musculoskeletal Radiology, University of California, San Diego, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA 92162, San Diego (United States); Johnson, K.; Terkeltaub, R.; Resnick, D. [Department of Rheumatology, University of California, San Diego, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA 92162, San Diego (United States); Pe, S. [University of California, San Diego, VA San Diego Healthcare System, 3350 La Jolla Village Drive, CA 92162, San Diego (United States)

    2004-07-01

    To demonstrate and determine the frequency and location of calcification within cadaveric knees with or without calcification typical of calcium pyrophosphate dihydrate (CPPD), utilizing histologic, radiographic and MR imaging techniques. Ten cadaveric knees of elderly individuals that demonstrated no radiographic evidence of prior surgery or trauma were studied with MR imaging and subsequently sectioned in planes corresponding to those obtained with MR imaging. The slices were imaged with high-resolution radiography. Two musculoskeletal radiologists correlated the anatomic, MR and radiographic findings. Three of the knees, which did not demonstrate calcifications, were utilized as controls. Histologic sections were obtained from four knees that contained calcifications and from the three controls, and analyzed with special histologic stains that demonstrate phosphorus and calcium. Radiographic imaging and histologic analysis demonstrated widespread CPPD crystal deposition in four of the 10 knee specimens (40%). MR imaging demonstrated some calcifications only within the articular cartilage of the femoral condyles in three of the four (75%) specimens that had CPPD deposits. In all four specimens radiographs and histologic analysis were more sensitive than MR imaging. Histologic analysis demonstrated no evidence of CPPD crystals in the control specimens. MR imaging is insensitive to the presence of CPPD deposits in the knee, even when such deposits are widespread. Our study suggests that the sensitivity of MR imaging was significantly better in detecting CPPD deposits in the hyaline cartilage of the femoral condyles when compared with other internal structures, even when such structures contained a higher amount of calcification. (orig.)

  5. Droplet Microfluidics Approach for Single-DNA Molecule Amplification and Condensation into DNA-Magnesium-Pyrophosphate Particles

    Directory of Open Access Journals (Sweden)

    Greta Zubaite

    2017-02-01

    Full Text Available Protein expression in vitro has broad applications in directed evolution, synthetic biology, proteomics and drug screening. However, most of the in vitro expression systems rely on relatively high DNA template concentrations to obtain sufficient amounts of proteins, making it harder to perform in vitro screens on gene libraries. Here, we report a technique for the generation of condensed DNA particles that can serve as efficient templates for in vitro gene expression. We apply droplet microfluidics to encapsulate single-DNA molecules in 3-picoliter (pL volume droplets and convert them into 1 μm-sized DNA particles by the multiple displacement amplification reaction driven by phi29 DNA polymerase. In the presence of magnesium ions and inorganic pyrophosphate, the amplified DNA condensed into the crystalline-like particles, making it possible to purify them from the reaction mix by simple centrifugation. Using purified DNA particles, we performed an in vitro transcription-translation reaction and successfully expressed complex enzyme β-galactosidase in droplets and in the 384-well format. The yield of protein obtained from DNA particles was significantly higher than from the corresponding amount of free DNA templates, thus opening new possibilities for high throughput screening applications.

  6. Effect of irradiation and soaking in BHT and sodium pyrophosphate on meat proteins and lipids during cold storage

    International Nuclear Information System (INIS)

    Hassan, I.M.; Emam, O.A.

    1988-01-01

    The effect of irradiation treatments up to 10 KGy, soaking in a solution containing 0.5% Na-pyrophosphate and 250 ppm butylated hydroxy toluene (BHT) and a combination of both treatments on the nitrogen content and solubility, protein fractions and lipids stability in beef steaks during cold storage at 4 ± 1°C was followed until the samples were rejected by sensory evaluation. The least effective radiation doses for soluble protein nitrogen (SPN), total soluble nitrogen (TSN) and total nitrogen (TN) were 2, 5 and 10 KGy, respectively. Such effects were proportionally related to the applied dose. The loss in nitrogen compounds and/or their solubility which occurred upon irradiation appeared to be retarded by soaking treatment. Irradiation treatments induced additional protein fraction which seems to be originated from the sarcoplasmic proteins. After the resolution of rigor mortis, the incremental rate of nitrogen extractability was inversely related to the irradiation dose. Another protein fraction was detected only in the 10 KGy irradiated samples after 14 days of cold storage which might be originating from fibrillar proteins as a result of its interaction with some lipid oxidation products. However, soaking treatment itself caused extensive changes in protein fractions, in contrast, protection from radiation and radiation after-effects were observed

  7. Unexpected myocardial uptake on bone scintigraphy in an infant with Kawasaki disease

    International Nuclear Information System (INIS)

    Macdonald, W.B.G.; Troedson, R.G.

    2003-01-01

    Full text: A two-month-old female infant was admitted to hospital because of irritability and poor feeding over the preceding two weeks. There was no history of fever but serum inflammatory markers were elevated and a throat swab yielded a pure growth of Strep, pyogenes. There was no response to antibiotics. The nursing staff noted the infant disliked handling and skeletal pathology was suspected. A bone scan using Tc-99m hydroxymethylene diphosphonate (HDP) showed myocardial activity, with no evidence of abnormal skeletal activity. Subsequent echocardiography showed coronary artery ectasia, typical of Kawasaki disease, with papillary muscle dysfunction, indicating likely myocarditis. A diagnosis of myocarditis secondary to Kawasaki disease was made and the patient promptly improved following intravenous immunoglobulin therapy. Cardiac manifestations of Kawasaki disease included coronary artery aneurysms, myocardial infarction, regional perfusion abnormalities and myocarditis. Myocardial uptake of phosphate tracers is well known following myocardial infarction but there was no wall motion disturbance or ECG abnormality to suggest infarction in this patient and she was felt to have myocarditis. Myocardial uptake of phosphate tracers has not previously been reported in Kawasaki disease. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  8. Myocardial contusion in patients with blunt chest trauma as evaluated by thallium 201 myocardial scintigraphy

    International Nuclear Information System (INIS)

    Bodin, L.; Rouby, J.J.; Viars, P.

    1988-01-01

    Fifty five patients suffering from blunt chest trauma were studied to assess the diagnosis of myocardial contusion using thallium 201 myocardial scintigraphy. Thirty-eight patients had consistent scintigraphic defects and were considered to have a myocardial contusion. All patients with scintigraphic defects had paroxysmal arrhythmias and/or ECG abnormalities. Of 38 patients, 32 had localized ST-T segment abnormalities; 29, ST-T segment abnormalities suggesting involvement of the same cardiac area as scintigraphic defects; 21, echocardiographic abnormalities. Sixteen patients had segmental hypokinesia involving the same cardiac area as the scintigraphic defects. Fifteen patients had clinical signs suggestive of myocardial contusion and scintigraphic defects. Almost 70 percent of patients with blunt chest trauma had scintigraphic defects related to areas of myocardial contusion. When thallium 201 myocardial scintigraphy directly showed myocardial lesion, two-dimensional echocardiography and standard ECG detected related functional consequences of cardiac trauma

  9. Clinical Characteristics and Outcomes of Patients with Myocardial Infarction, Myocardial Injury, and Nonelevated Troponins

    DEFF Research Database (Denmark)

    Sarkisian, Laura; Saaby, Lotte; Poulsen, Tina S

    2016-01-01

    BACKGROUND: Cardiac troponins have emerged as the preferred biomarkers for detecting myocardial necrosis and diagnosing myocardial infarction. However, current cardiac troponin assays do not discriminate between ischemic and nonischemic causes of myocardial cell death. Thus, when an increased...... troponin value is encountered in the absence of obvious myocardial ischemia, a careful search for other clinical conditions is crucial. METHODS: In 2010 to 2011, we prospectively studied hospitalized patients who had cardiac troponin I measured on clinical indication. An acute myocardial infarction...... was diagnosed in cases of a cardiac troponin I increase or decrease pattern with at least 1 value >30 ng/L (99th percentile) together with myocardial ischemia. Myocardial injury was defined as cardiac troponin I values >30 ng/L, but without signs or symptoms indicating overt cardiac ischemia. Patients with peak...

  10. Comparison of myocardial perfusion imaging between the new high-speed gamma camera and the standard anger camera

    International Nuclear Information System (INIS)

    Tanaka, Hirokazu; Chikamori, Taishiro; Hida, Satoshi

    2013-01-01

    Cadmium-zinc-telluride (CZT) solid-state detectors have been recently introduced into the field of myocardial perfusion imaging. The aim of this study was to prospectively compare the diagnostic performance of the CZT high-speed gamma camera (Discovery NM 530c) with that of the standard 3-head gamma camera in the same group of patients. The study group consisted of 150 consecutive patients who underwent a 1-day stress-rest 99m Tc-sestamibi or tetrofosmin imaging protocol. Image acquisition was performed first on a standard gamma camera with a 15-min scan time each for stress and for rest. All scans were immediately repeated on a CZT camera with a 5-min scan time for stress and a 3-min scan time for rest, using list mode. The correlations between the CZT camera and the standard camera for perfusion and function analyses were strong within narrow Bland-Altman limits of agreement. Using list mode analysis, image quality for stress was rated as good or excellent in 97% of the 3-min scans, and in 100% of the ≥4-min scans. For CZT scans at rest, similarly, image quality was rated as good or excellent in 94% of the 1-min scans, and in 100% of the ≥2-min scans. The novel CZT camera provides excellent image quality, which is equivalent to standard myocardial single-photon emission computed tomography, despite a short scan time of less than half of the standard time. (author)

  11. Nifedipine for angina and acute myocardial ischemia

    NARCIS (Netherlands)

    P.G. Hugenholtz (Paul); J.W. de Jong (Jan Willem); P.D. Verdouw (Pieter); P.W.J.C. Serruys (Patrick)

    1983-01-01

    textabstractThis paper reviews the mechanisms believed to be responsible for myocardial ischaemia and the mode of action of calcium antagonist drugs. The clinical management of patients with myocardial ischaemia is discussed in the context of current knowledge about patho-physiology and drug action.

  12. The end of the unique myocardial band

    DEFF Research Database (Denmark)

    MacIver, David H; Partridge, John B; Agger, Peter

    2018-01-01

    Two of the leading concepts of mural ventricular architecture are the unique myocardial band and the myocardial mesh model. We have described, in an accompanying article published in this journal, how the anatomical, histological and high-resolution computed tomographic studies strongly favour th...

  13. When is 201Tl myocardial scintigraphy indicated?

    International Nuclear Information System (INIS)

    Klepzig, H. Jr.; Kaltenbach, M.

    1987-01-01

    Myocardial scintigraphy with thallium-201 has met with good acceptance in cardiology and has proven its value. The method implies only low risk and yields diagnostic results that allow verification or disqualification of suspected myocardial ischemia in those cases where there is only reduced accuracy of the exercise electrocardiogram. (TRV) [de

  14. Do episodes of anger trigger myocardial infarction?

    DEFF Research Database (Denmark)

    Möller, J; Hallqvist, J; Diderichsen, Finn

    1999-01-01

    Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility.......Our objectives were to study anger as a trigger of acute myocardial infarction (MI) and to explore potential effect modification by usual behavioral patterns related to hostility....

  15. Lung PET scan

    Science.gov (United States)

    ... Chest PET scan; Lung positron emission tomography; PET - chest; PET - lung; PET - tumor imaging; ... Grainger & Allison's Diagnostic Radiology: A Textbook of Medical Imaging . 6th ed. Philadelphia, ...

  16. Scanning of bone metastases

    International Nuclear Information System (INIS)

    Robillard, J.

    1977-01-01

    The Centers against cancer of Caen, Angers, Montpellier, Strasbourg and 'the Curie Foundation' have confronted their experience in detection of bone metastases by total body scanning. From the investigation by this procedure, of 1,467 patients with cancer, it results: the confrontation between radio and scanning shows a rate of false positive and false negative identical to the literature ones; the countage scanning allows to reduce the number of false positive; scanning allows to direct bone biopsy and to improve efficiency of histological examination [fr

  17. Myocardial viability assessment with dynamic low-dose iodine-123-iodophenylpentadecanoic acid metabolic imaging: comparison with myocardial biopsy and reinjection SPECT thallium after myocardial infarction.

    Science.gov (United States)

    Murray, G L; Schad, N C; Magill, H L; Vander Zwaag, R

    1994-04-01

    Aggressive cardiac revascularization requires recognition of stunned and hibernating myocardium, and cost considerations may well govern the technique used. Dynamic low-dose (1 mCi) [123I]iodophenylpentadecanoic acid (IPPA) metabolic imaging is a potential alternative to PET using either 18FDG or 15O-water. Resting IPPA images were obtained from patients with severe ischemic cardiomyopathy, and transmural myocardial biopsies were obtained during coronary bypass surgery to confirm viability. Thirty-nine of 43 (91%) biopsies confirmed the results of the IPPA images with a sensitivity for viability of 33/36 (92%) and a specificity of 6/7 (86%). Postoperatively, wall motion improved in 80% of IPPA-viable, dysfunctional segments. Furthermore, when compared to reinjection thallium (SPECT-TI) scans after myocardial infarction, IPPA-SPECT-TI concordance occurred in 27/35 (77%) (K = 0.536, p = 0.0003). Similar to PET, IPPA demonstrated more viability than SPECT-TI, 26/35 (74%) versus 18/35 (51%) (p = 0.047). Metabolic IPPA cardiac viability imaging is a safe, inexpensive technique that may be a useful alternative to PET.

  18. Monitoring of myocardial edema following acute myocardial infarction

    International Nuclear Information System (INIS)

    Tahir, E.; Sinn, M.; Avanesov, M.; Wien, J.; Saering, D.; Stehning, C.; Radunski, U. K.; Muellerleile, K.; Adam, G.; Lund, G. K.

    2015-01-01

    Full text: Currently, myocardial edema monitoring after acute myocardial infarction (AMI) is based on visualization of the region with increased signal-intensity on T2-weighted images. Native T1 and T2 mapping are promising novel MRI techniques to quantitatively assess myocardial edema. The purpose of the study was to quantitatively evaluate resorption of myocardial edema following AMI by native T1 and T2 -mapping cardiac magnetic resonance imaging (CMR). CMR (1.5 Tesla Philips Achieva) was performed in 30 patients four times after reperfused AMI at baseline (BL) at 9±6 days after infarction and at 7±1 weeks (follow-up 1, FU1), 3.6±0.5 months (FU2) and 6.5±0.7 months (FU3), respectively. Edema sensitive black-blood T2-weighted (T2w) STIR CMR was performed on end-diastolic LV short-axes. A free-breathing, navigatorgated multi-echo sequence was used for short-axis T2 mapping. T1 mapping was performed using the modified look-locker inversion recovery (MOLLI) sequence. T2 maps were calculated from nine and T1 maps from eight echoes using a dedicated plug-in written for OsiriX software. Two experienced observers independently evaluated T2w-CMR as well as T1 and T2 mapping using the HeAT-Software applying a threshold method. Size of edema and prolongation of the native T1- or T2-time was measured using a cutoff >2SD of remote normal myocardium. Edema size continuously decreased from BL with 32.8 %LV to 24.6 %LV at FU1, to 19.1 %LV at FU2 and to 16.4 %LV at FU3 using T2w-CMR. An almost identical decrease of edema size was observed using native T1 and T2 - mapping. T2 times only decreased between BL from 79±5 ms to 73±2 ms at FU1 (P<0.05), but no further change was observed at later time points with 70±5 ms at FU2 and 70±6 ms at FU3. At all time points the T2 times of remote normal myocardium were about 50±2 ms and significantly lower compared to the edema zone. Also native T1 time within the edema was with 1253 ±103 ms significantly increased compared to remote

  19. Myocardial oxygen extraction fraction measured using bolus inhalation of 15O-oxygen gas and dynamic PET

    NARCIS (Netherlands)

    Lubberink, Mark; Wong, YY; Raijmakers, P. G.; Huisman, Marc C.; Schuit, Robert C.; Luurtsema, Geert; Boellaard, Ronald; Knaapen, P; Vonk-Noordegraaf, Anton; Lammertsma, Adriaan A.

    Abstract The aim of this study was to determine the accuracy of oxygen extraction fraction (OEF) measurements using a dynamic scan protocol after bolus inhalation of 15O2. The method of analysis was optimized by investigating potential reuse of myocardial blood flow (MBF), perfusable tissue

  20. Residual Activity Correction in Quantitative Myocardial Perfusion N-13-Ammonia PET Imaging : A Study in Post-MI Patients

    NARCIS (Netherlands)

    Markousis-Mavrogenis, George; Juarez-Orozco, Luis Eduardo; Alexanderson, Erick

    2017-01-01

    Background/Introduction/Aim: Positron emission tomography (PET) is the gold standard for the quantification of myocardial blood flow (MBF). A standard PET scan is acquired in two phases (rest and pharmacological stress). N-13-ammonia is a perfusion radiotracer that may show residual activity, which

  1. Evaluation of /sup 111/In leukocyte whole body scanning

    Energy Technology Data Exchange (ETDEWEB)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-11-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with /sup 111/In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes.

  2. Evaluation of 111In leukocyte whole body scanning

    International Nuclear Information System (INIS)

    McDougall, I.R.; Baumert, J.E.; Lantieri, R.L.

    1979-01-01

    Indium-111 oxine, polymorphonuclear cells isolated and labeled with 111 In were used for studying abscesses and inflammatory conditions. There were 64 total scans done in 59 patients, 32 male and 27 female, aged 3 to 81 years (average, 51). The original clinical diagnosis was abscess in 33 patients. The whole blood cell scan was abnormal in 12 (36%) of these, and a good clinical correlation was obtained in 11 of the 12. In the 21 with a normal scan, 18 had no evidence of abscess, yielding one false-positive and three false-negative interpretations in the abscess group. Thirteen patients had fever of unknown origin, nine had negative scans and no subsequent evidence of abscess, and four had positive scans with good correlation in three. Acute bone and joint infections were positive on scan (4/4), whereas chronic osteomyelitis was negative (0/2). Three patients with acute myocardial infarction and three of four with subacute bacterial endocarditis had normal scans. All three studies in renal transplant rejection showed positive uptake in the pelvic kidneys. Indium-111 white blood cell scans have proved useful to diagnose or exclude a diagnosis of abscess or inflammatory condition infiltrated with polymorphonuclear leukocytes

  3. Model PET Scan Activity

    Science.gov (United States)

    Strunk, Amber; Gazdovich, Jennifer; Redouté, Oriane; Reverte, Juan Manuel; Shelley, Samantha; Todorova, Vesela

    2018-05-01

    This paper provides a brief introduction to antimatter and how it, along with other modern physics topics, is utilized in positron emission tomography (PET) scans. It further describes a hands-on activity for students to help them gain an understanding of how PET scans assist in detecting cancer. Modern physics topics provide an exciting way to introduce students to current applications of physics.

  4. Scanning laser Doppler vibrometry

    DEFF Research Database (Denmark)

    Brøns, Marie; Thomsen, Jon Juel

    With a Scanning Laser Doppler Vibrometer (SLDV) a vibrating surface is automatically scanned over predefined grid points, and data processed for displaying vibration properties like mode shapes, natural frequencies, damping ratios, and operational deflection shapes. Our SLDV – a PSV-500H from...

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake Thyroid scan and uptake uses ...

  6. Transverse section scanning mechanism

    International Nuclear Information System (INIS)

    Doherty, E.J.

    1978-01-01

    Apparatus is described for scanning a transverse, radionuclide scan-field using an array of focussed collimators. The collimators are movable tangentially on rails, driven by a single motor via a coupled screw. The collimators are also movable in a radial direction on rails driven by a step motor via coupled screws and bevel gears. Adjacent bevel gears rotate in opposite directions so adjacent collimators move in radially opposite directions. In use, the focal point of each collimator scans at least half of the scan-field, e.g. a human head located in the central aperture, and the electrical outputs of detectors associated with each collimator are used to determine the distribution of radioactive emission intensity at a number of points in the scan-field. (author)

  7. Direct Evidence that Myocardial Insulin Resistance following Myocardial Ischemia Contributes to Post-Ischemic Heart Failure

    Science.gov (United States)

    Fu, Feng; Zhao, Kun; Li, Jia; Xu, Jie; Zhang, Yuan; Liu, Chengfeng; Yang, Weidong; Gao, Chao; Li, Jun; Zhang, Haifeng; Li, Yan; Cui, Qin; Wang, Haichang; Tao, Ling; Wang, Jing; Quon, Michael J; Gao, Feng

    2015-01-01

    A close link between heart failure (HF) and systemic insulin resistance has been well documented, whereas myocardial insulin resistance and its association with HF are inadequately investigated. This study aims to determine the role of myocardial insulin resistance in ischemic HF and its underlying mechanisms. Male Sprague-Dawley rats subjected to myocardial infarction (MI) developed progressive left ventricular dilation with dysfunction and HF at 4 wk post-MI. Of note, myocardial insulin sensitivity was decreased as early as 1 wk after MI, which was accompanied by increased production of myocardial TNF-α. Overexpression of TNF-α in heart mimicked impaired insulin signaling and cardiac dysfunction leading to HF observed after MI. Treatment of rats with a specific TNF-α inhibitor improved myocardial insulin signaling post-MI. Insulin treatment given immediately following MI suppressed myocardial TNF-α production and improved cardiac insulin sensitivity and opposed cardiac dysfunction/remodeling. Moreover, tamoxifen-induced cardiomyocyte-specific insulin receptor knockout mice exhibited aggravated post-ischemic ventricular remodeling and dysfunction compared with controls. In conclusion, MI induces myocardial insulin resistance (without systemic insulin resistance) mediated partly by ischemia-induced myocardial TNF-α overproduction and promotes the development of HF. Our findings underscore the direct and essential role of myocardial insulin signaling in protection against post-ischemic HF. PMID:26659007

  8. Three-dimension structure of ventricular myocardial fibers after myocardial infarction

    Directory of Open Access Journals (Sweden)

    Li Libin

    2010-11-01

    Full Text Available Abstract Background To explore the pathological changes of three-dimension structure of ventricular myocardial fibers after anterior myocardial infarction in dog heart. Methods Fourteen acute anterior myocardial infarction models were made from healthy dogs (mean weight 17.6 ± 2.5 kg. Six out of 14 dogs with old myocardial infarction were sacrificed, and their hearts were harvested after they survived the acute anterior myocardial infarction for 3 months. Each heart was dissected into ventricular myocardial band (VMB, morphological characters in infarction region were observed, and infarct size percents in descending segment and ascending segment were calculated. Results Six dog hearts were successfully dissected into VMB. Uncorresponding damages in myocardial fibers of descending segment and ascending segment were found in apical circle in anterior wall infarction. Infarct size percent in the ascending segment was significantly larger than that in the descending segment (23.36 ± 3.15 (SD vs 30.69 ± 2.40%, P = 0.0033; the long axis of infarction area was perpendicular to the orientation of myocardial fibers in ascending segment; however, the long axis of the infarction area was parallel with the orientation of myocardial fibers in descending segment. Conclusions We found that damages were different in both morphology and size in ascending segment and descending segment in heart with myocardial infarction. This may provide an important insight for us to understand the mechanism of heart failure following coronary artery diseases.

  9. Diagnostic value of exercise induced 18F-FDG myocardial metabolism scintigraphy in myocardial ischemia

    International Nuclear Information System (INIS)

    Shen Rui; He Zuoxiang; Shi Rongfang; Liu Xiujie; Tian Yueqin; Guo Feng; Wei Hongxing; Wu Yongjian; Qin Xuewen; Gao Runlin

    2006-01-01

    Objective: To evaluate the feasibility and diagnostic accuracy of exercise induced myocardial imaging with 18 F-fluorodeoxyglucose (FDG) in myocardial ischemia. Methods: Twenty-six patients with known or suspected coronary artery, disease (CAD) and with no prior myocardial infarction underwent simultaneous myocardial perfusion and metabolism imaging following intravenous injection of 99 Tc m -methoxy-isobutylisonitrile ( 99 Tc m -sestamibi) and 18 F-FDG at peak exercise. Subsequently rest perfusion imaging and coronary angiography (CAG) were performed in all patients. Exercise 18 F-FDG myocardial imaging was compared with 99 Tc m -sestamibi imaging and CAG. Results: In 22 patients with ≥50% narrowing over l coronary artery, 18 had perfusion abnormalities (sensitivity 82%), whereas 20 had abnormal myocardial 18 F-FDG uptake (sensitivity 91%, P>0.05). Patients with reversible (12 cases) or partial reversible (3 cases) perfusion abnormalities had increased myocardial 18 F-FDG uptake in abnormal perfusion segments. Compared with CAG, perfusion defect was seen in myocardial segments corresponding to 25 vascular territories of 51 vessels with ≥50% narrowing in 22 patients in 99 Tc m -sestamibi imaging (sensitivity 49%), whereas increased 18 F-FDG uptake was seen in 34 vascular territories (sensitivity 67%, P=0.008). Conclusions: Exercise induced myocardial ischemia can be imaged directly with 18 F-FDG. Combined exercise 18 F-FDG and 99 Tc m -sestamibi imaging provides a better assessment of exercise-induced myocardial ischemia as compared with exercise-rest perfusion imaging. (authors)

  10. Clinical assessment of the early myocardial Tc-99m-PYP uptake as an indicator of successful recanalization in the acutely infarcted vessels

    International Nuclear Information System (INIS)

    Kondo, Makoto; Yuzuki, Yousuke; Miyazaki, Yukio; Kurose, Takesi; Matsunaga, Kazuhiko; Simono, Yukio

    1986-01-01

    A noninvasive useful method is required to early ascertain the effect of intracoronary thrombolysis (ICT) currently performed for acute myocardial infarction (AMI). In the present study, Tc-99m-pyrophosphate (PYP) scintigraphy was performed early (2.8 - 9.3 hr) after the onset of symptoms in 34 patients undergoing ICT. Of 27 patients in whom favorable recanalization was obtained, 24 had positive early scintigrams. In the other 7 patients in whom ICT was unsuccessful, scintigrams were negative. In 3 of them, favorable collateral circulation was seen. The findings were compared with those within 16 hr after the onset for the peak levels of creatine kinase (CK) and MB-CK. Early PYP scintigraphy had a sensitivity of 89 %, specificity of 100 %, and predictive accuracy of 91 % in assessing the recanalization in the infarcted vessels. The corresponding figiures were 70 %, 86 %, and 74 % for CK levels; and 70 %, 71 %, and 71 % for MB-CK levels. The results indicate that PYP scintigraphy may be a useful aid in the diagnosis of recanalization. The mechanism for PYP uptake on early scintigrams may be explained by the passage of excessive Ca ion into the ischemic myocardial cells through the rapid recanalization, resulting in accelerated cell death (reperfusion necrosis). (Namekawa, K.)

  11. Clinical assessment of the early myocardial Tc-99m-PYP uptake as an indicator of successful recanalization in the acutely infarcted vessels

    Energy Technology Data Exchange (ETDEWEB)

    Kondo, Makoto; Yuzuki, Yousuke; Miyazaki, Yukio; Kurose, Takesi; Matsunaga, Kazuhiko; Simono, Yukio

    1986-11-01

    A noninvasive useful method is required to early ascertain the effect of intracoronary thrombolysis (ICT) currently performed for acute myocardial infarction (AMI). In the present study, Tc-99m-pyrophosphate (PYP) scintigraphy was performed early (2.8 - 9.3 hr) after the onset of symptoms in 34 patients undergoing ICT. Of 27 patients in whom favorable recanalization was obtained, 24 had positive early scintigrams. In the other 7 patients in whom ICT was unsuccessful, scintigrams were negative. In 3 of them, favorable collateral circulation was seen. The findings were compared with those within 16 hr after the onset for the peak levels of creatine kinase (CK) and MB-CK. Early PYP scintigraphy had a sensitivity of 89 %, specificity of 100 %, and predictive accuracy of 91 % in assessing the recanalization in the infarcted vessels. The corresponding figiures were 70 %, 86 %, and 74 % for CK levels; and 70 %, 71 %, and 71 % for MB-CK levels. The results indicate that PYP scintigraphy may be a useful aid in the diagnosis of recanalization. The mechanism for PYP uptake on early scintigrams may be explained by the passage of excessive Ca ion into the ischemic myocardial cells through the rapid recanalization, resulting in accelerated cell death (reperfusion necrosis). (Namekawa, K.).

  12. LIDAR COMBINED SCANNING UNIT

    Directory of Open Access Journals (Sweden)

    V. V. Elizarov

    2016-11-01

    Full Text Available Subject of Research. The results of lidar combined scanning unit development for locating leaks of hydrocarbons are presented The unit enables to perform high-speed scanning of the investigated space in wide and narrow angle fields. Method. Scanning in a wide angular field is produced by one-line scanning path by means of the movable aluminum mirror with a frequency of 20Hz and amplitude of 20 degrees of swing. Narrowband scanning is performed along a spiral path by the deflector. The deflection of the beam is done by rotation of the optical wedges forming part of the deflector at an angle of ±50. The control function of the scanning node is performed by a specialized software product written in C# programming language. Main Results. This scanning unit allows scanning the investigated area at a distance of 50-100 m with spatial resolution at the level of 3 cm. The positioning accuracy of the laser beam in space is 15'. The developed scanning unit gives the possibility to browse the entire investigated area for the time not more than 1 ms at a rotation frequency of each wedge from 50 to 200 Hz. The problem of unambiguous definition of the beam geographical coordinates in space is solved at the software level according to the rotation angles of the mirrors and optical wedges. Lidar system coordinates are determined by means of GPS. Practical Relevance. Development results open the possibility for increasing the spatial resolution of scanning systems of a wide range of lidars and can provide high positioning accuracy of the laser beam in space.

  13. Quantitative assessment of the infarct size with the unfolded map method of sup 201 Tl myocardial SPECT in patient with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Kubota, Masahiro (Sapporo Medical Coll. (Japan))

    1992-03-01

    The unfolded map method of {sup 201}Tl single photon emission computed tomography (SPECT) was evaluated as to the ability to quantify and the clinical reliability in estimation of infarct size. The following results were obtained from basic experiments using a thoracic phantom. The defect area estimated by the unfolded map method was well correlated with the real defect area, in spite of overestimation of the defect area, when the defect area was determined by an isocount method (below 80% of maximum count) (y=1.941 + 2.292x, r=0.971). The defect volume estimated by short-axis images of {sup 201}Tl SPECT was closely correlated with real defect volume in spite of overestimation of defect volume (y=0.762 + 2.156x, r=0.982). When the defect area was estimated by division of the defect volume by the mean myocardial compartment thickness, it was closely correlated with real defect area (y=0.946 + 1.232x, r=0.990). When the volume was calculated from the summation of voxels in the regions districted by isocount threshold level at each section of the {sup 99m}Tc SPECT, the optimal isocount threshold level (percentage to maximum count) was 55%. Then, the clinical reliability of the unfolded map method as infarct sizing was evaluated in 26 patients with acute myocardial infarction by comparing it with enzymatic method, Bull's eye method, and {sup 99m}Tc pyrophosphate (PYP) SPECT method. In 14 first attack patients without right ventricular infarction, infarct area (IA) of the unfolded map method correlated most closely with the accumulated creatine kinase MB isoenzyme release (CK-MBr) (r=0.897), compared with the extent score (ES) (r=0.853) and the severity score (SS) (r=0.871) of Bull's eye method and the infarct volume (IV) (r=0.595) of {sup 99m}Tc PYP SPECT. In conclusion, although the unfolded map method of {sup 201}Tl SPECT has the tendency for overestimating infarct size, it is accurate and clinically reliable in estimating infarct size. (author).

  14. Regional myocardial extraction of a radioiodinated branched chain fatty acid during right ventricular pressure overload due to acute pulmonary hypertension

    International Nuclear Information System (INIS)

    Hurford, W.; Lowenstein, E.; Zapol, W.; Barlai-Kovach, M.; Livni, E.; Elmaleh, D.R.; Strauss, H.W.

    1985-01-01

    To determine whether branched chain fatty acid extraction is reduced during right ventricular (RV) dysfunction due to acute pulmonary artery hypertension, studies were done in 6 anesthetized dogs. Regional branched chain fatty acid extraction was measured by comparing the myocardial uptake of I-125 labeled 15-[p-(iodophenyl)]-3-methylpentadecanoic acid (I-PDA) to myocardial blood flow. Acute pulmonary hypertension was induced by incremental intravenous injection of 100 micron diameter glass beads into six pentobarbital anesthetized, mechanically ventilated dogs. Myocardial blood flow was measured by radiolabeled microspheres both under baseline conditions and during pulmonary hypertension. Mean RV pressure rose from 12 +- 2 (mean +- SEM) to 30 +-3mmHg resulting in a 225 +- 16% increase in RV stroke work. RV ejection fraction, as assessed by gated blood pool scans fell from 39 +- 2 to 18 +- 2%. Left ventricular (LV) pressures, stroke work and ejection fraction were unchanged. Myocardial blood flow increased 132 + 59% in the RV free wall and 67 +- 22% in the RV septum. LV blood flow was unchanged. Despite increased RV work and myocardial blood flow, no differences were noted in the branched chain fatty acid extraction ratios among LV or RV free walls or septum. The authors conclude that early RV dysfunction associated with pulmonary artery hypertension is not due to inadequate myocardial blood flow or branched chain fatty acid extraction

  15. Myocardial perfusion imaging with dual energy CT

    Energy Technology Data Exchange (ETDEWEB)

    Jin, Kwang Nam [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiology, SMG-SNU Boramae Medical Center, Seoul (Korea, Republic of); De Cecco, Carlo N. [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Caruso, Damiano [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Radiological Sciences, Oncology and Pathology, University of Rome “Sapienza”, Rome (Italy); Tesche, Christian [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Department of Cardiology and Intensive Care Medicine, Heart Center Munich-Bogenhausen, Munich (Germany); Spandorfer, Adam; Varga-Szemes, Akos [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Schoepf, U. Joseph, E-mail: schoepf@musc.edu [Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, SC (United States); Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC (United States)

    2016-10-15

    Highlights: • Stress dual-energy sCTMPI offers the possibility to directly detect the presence of myocardial perfusion defects. • Stress dual-energy sCTMPI allows differentiating between reversible and fixed myocardial perfusion defects. • The combination of coronary CT angiography and dual-energy sCTMPI can improve the ability of CT to detect hemodynamically relevant coronary artery disease. - Abstract: Dual-energy CT (DECT) enables simultaneous use of two different tube voltages, thus different x-ray absorption characteristics are acquired in the same anatomic location with two different X-ray spectra. The various DECT techniques allow material decomposition and mapping of the iodine distribution within the myocardium. Static dual-energy myocardial perfusion imaging (sCTMPI) using pharmacological stress agents demonstrate myocardial ischemia by single snapshot images of myocardial iodine distribution. sCTMPI gives incremental values to coronary artery stenosis detected on coronary CT angiography (CCTA) by showing consequent reversible or fixed myocardial perfusion defects. The comprehensive acquisition of CCTA and sCTMPI offers extensive morphological and functional evaluation of coronary artery disease. Recent studies have revealed that dual-energy sCTMPI shows promising diagnostic accuracy for the detection of hemodynamically significant coronary artery disease compared to single-photon emission computed tomography, invasive coronary angiography, and cardiac MRI. The aim of this review is to present currently available DECT techniques for static myocardial perfusion imaging and recent clinical applications and ongoing investigations.

  16. Localization of the 5-phospho-alpha-D-ribosyl-1-pyrophosphate binding site of human hypoxanthine-guanine phosphoribosyltransferase.

    Science.gov (United States)

    Keough, D T; Emmerson, B T; de Jersey, J

    1991-02-22

    Human erythrocyte hypoxanthine-guanine phosphoribosyltransferase (HPRT) is inactivated by iodoacetate in the absence, but not in the presence, of the substrate, 5-phospho-alpha-D-ribosyl-1-pyrophosphate (PRib-PP). Treatment of HPRT with [14C]iodoacetate followed by tryptic digestion, peptide separation and sequencing has shown that Cys-22 reacts with iodoacetate only in the absence of PRib-PP; this strongly suggests that Cys-22 is in or near the PRib-PP binding site. In contrast, Cys-105 reacts with [14C]iodoacetate both in the presence and absence of PRib-PP. Carboxymethylation of Cys-22 resulted in an increase in the Km for PRib-PP, but no change in Vmax. Storage of HPRT also resulted in an increase in the Km for PRib-PP and a decrease in its susceptibility to inactivation by iodoacetate. Dialysis of stored enzyme against 1 mM dithiothreitol resulted in a marked decrease in Km for PRib-PP. The stoichiometry of the reaction of [14C]iodoacetate with Cys-22 in HPRT leading to inactivation (approx. 1 residue modified per tetramer) showed that, in this preparation of HPRT purified from erythrocytes, only about 25% of the Cys-22 side chains were present as free and accessible thiols. Titration of thiol groups [with 5,5'-dithiobis(2-nitrobenzoic acid)] and the effect of dithiothreitol on Km for PRib-PP indicate that oxidation of thiol groups occurs on storage of HPRT, even in the presence of 1 mM beta-mercaptoethanol.

  17. Does ascorbic acid supplementation affect iron bioavailability in rats fed micronized dispersible ferric pyrophosphate fortified fruit juice?

    Science.gov (United States)

    Haro-Vicente, Juan Francisco; Pérez-Conesa, Darío; Rincón, Francisco; Ros, Gaspar; Martínez-Graciá, Carmen; Vidal, Maria Luisa

    2008-12-01

    Food iron (Fe) fortification is an adequate approach for preventing Fe-deficiency anemia. Poorly water-soluble Fe compounds have good sensory attributes but low bioavailability. The reduction of the particle size of Fe fortificants and the addition of ascorbic acid might increase the bioavailability of low-soluble compounds. The present work aims to compare the Fe absorption and bioavailability of micronized dispersible ferric pyrophosphate (MDFP) (poorly soluble) to ferrous sufate (FS) (highly soluble) added to a fruit juice in presence or absence of ascorbic acid (AA) by using the hemoglobin repletion assay in rats. After a hemoglobin depletion period, four fruit juices comprised of (1) FS, (2) MDFP, (3) FS + AA, (4) MDFP + AA were produced and administered to a different group of rats (n = 18) over 21 days. During the repletion period, Fe balance, hemoglobin regeneration efficiency (HRE), relative bioavailability (RBV) and Fe tissue content were determined in the short, medium and long term. Fe absorption and bioavailability showed no significant differences between fortifying the fruit juice with FS or MDFP. The addition of AA to the juice enhanced Fe absorption during the long-term balance study within the same Fe source. HRE and Fe utilization increased after AA addition in both FS and MDFP groups in every period. Fe absorption and bioavailability from MDFP were comparable to FS added to a fruit juice in rats. Further, the addition of AA enhanced Fe absorption in the long term, as well as Fe bioavailability throughout the repletion period regardless of the Fe source employed.

  18. Early detection by sup(99m)Tc-Sn-pyrophosphate scintigraphy of femoral head necrosis following medial femoral neck fractures

    International Nuclear Information System (INIS)

    Greiff, J.; Lanng, S.; Hoeilund-Carlsen, P.F.; Karle, A.K.; Uhrenholdt, A.

    1980-01-01

    A selected series of 24 patients with displaced medial femoral neck fracture, treated with closed reduction and osteosynthesis with cancellous bone screws (ASIF), were investigated. During an observation period of 6 to 26 months, serial hip joint scintigraphies were performed and compared with serial X-ray examinations. At the first scintigraphic examination performed on average 5-6 weeks after the fracture, two separate investigators found a decreased amount of activity or no activity in the femoral head of 10 and 8 patients, respectively. At the second scintigraphic examination performed on average 11.1 weeks after the fracture both investigators found no activity or a decreased amount of activity in 8 patients. This figure declined to 7 during the following period, because one patient with decreased activity was recorded as having normal activity 15 months after the fracture. These 7 patients all developed radiological signs of femoral head collapse on average 16.3 months after the fracture (range 5-26 months), whereas their scintigrams displayed decreased or absent tracer uptake on average 1.2 months after the fracture (P<0.01). None of the patients with initially normal or increased uptake later showed decreased or absent uptake during the study and none developed radiological collapse. It may be concluded that absent or decreased uptake of sup(99m)Tc-Sn-pyrophosphate in the femoral head following medial femoral neck fracture indicates femoral head necrosis and a high risk of late segmental collapse, whereas normal or increased uptake implying preserved blood supply means that late segmental collapse will probably never develop. (author)

  19. Laser Scanning in Forests

    Directory of Open Access Journals (Sweden)

    Håkan Olsson

    2012-09-01

    Full Text Available The introduction of Airborne Laser Scanning (ALS to forests has been revolutionary during the last decade. This development was facilitated by combining earlier ranging lidar discoveries [1–5], with experience obtained from full-waveform ranging radar [6,7] to new airborne laser scanning systems which had components such as a GNSS receiver (Global Navigation Satellite System, IMU (Inertial Measurement Unit and a scanning mechanism. Since the first commercial ALS in 1994, new ALS-based forest inventory approaches have been reported feasible for operational activities [8–12]. ALS is currently operationally applied for stand level forest inventories, for example, in Nordic countries. In Finland alone, the adoption of ALS for forest data collection has led to an annual savings of around 20 M€/year, and the work is mainly done by companies instead of governmental organizations. In spite of the long implementation times and there being a limited tradition of making changes in the forest sector, laser scanning was commercially and operationally applied after about only one decade of research. When analyzing high-ranked journal papers from ISI Web of Science, the topic of laser scanning of forests has been the driving force for the whole laser scanning research society over the last decade. Thus, the topic “laser scanning in forests” has provided a significant industrial, societal and scientific impact. [...

  20. Bone scan in pediatrics

    International Nuclear Information System (INIS)

    Gordon, I.; Peters, A.M.

    1987-01-01

    In 1984, a survey carried out in 21 countries in Europe showed that bone scintigraphy comprised 16% of all paediatric radioisotope scans. Although the value of bone scans in paediatrics is potentially great, their quality varies greatly, and poor-quality images are giving this valuable technique a bad reputation. The handling of children requires a sensitive staff and the provision of a few simple inexpensive items of distraction. Attempting simply to scan a child between two adult patients in a busy general department is a recipe for an unhappy, uncooperative child with the probable result of poor images. The intravenous injection of isotope should be given adjacent to the gamma camera room, unless dynamic scans are required, so that the child does not associate the camera with the injection. This injection is best carried out by someone competent in paediatric venipunture; the entire procedure should be explained to the child and parent, who should remain with child throughout. It is naive to think that silence makes for a cooperative child. The sensitivity of bone-seeking radioisotope tracers and the marked improvement in gamma camera resolution has allowed the bone scanning to become an integrated technique in the assessment of children suspected of suffering from pathological bone conditions. The tracer most commonly used for routine bone scanning is 99m Tc diphosphonate (MDP); other isotopes used include 99m Tc colloid for bone marrow scans and 67 Ga citrate and 111 In white blood cells ( 111 In WBC) for investigation of inflammatory/infective lesions

  1. Nitrogen-13-labeled ammonia for myocardial imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, W.F.; Fill, H.R.; Harper, P.V.

    1977-01-01

    Cyclotron-produced nitrogen-13 (half-life 10 min), as labeled ammonia (/sup 13/NH/sub 4//sup +/), has been evaluated as a myocardial perfusion imaging agent. The regional myocardial uptake of /sup 13/NH/sub 4//sup +/ has been shown to be proportional to regional tissue perfusion in animal studies. Intravenously administered /sup 13/NH/sub 4//sup +/ is rapidly cleared from the circulation, being extracted by the liver (15 percent), lungs, myocardium (2 percent--4 percent), brain, kidney, and bladder. Myocardial ammonia is metabolized mainly to glutamine via the glutamine synthetase pathway. Pulmonary uptake is substantial, but usually transient, except in smokers where clearance may be delayed. The positron annihilation irradiation (511 keV) of /sup 13/N may be imaged with a scintillation camera, using either a specially designed tungsten collimator or a pinhole collimator. After early technical problems with collimation and the production method of /sup 13/NH/sub 4//sup +/ were overcome, reproducible high quality myocardial images were consistently obtained. The normal myocardial image was established to be of a homogeneous ''doughnut'' configuration. Imaging studies performed in patients with varying manifestations of ischemic and valvular heart disease showed a high incidence of localized perfusion defects, especially in patients with acute myocardial infarction. Sequential studies at short intervals in patients with acute infarction showed correlation between alterations in regional perfusion and the clinical course of the patient. It is concluded that myocardial imaging with /sup 13/NH/sub 4//sup +/ and a scintillation camera provides a valid and noninvasive means of assessing regional myocardial perfusion. This method is especially suitable for sequential studies of acute cardiac patients at short intervals. Coincidence imaging of the 511 keV annihilation irradiation provides a tomographic and potentially quantitative assessment of the

  2. Value of T1-201 myocardial perfusion scan for predicting prognosis in patients with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Suzuki, Yutaka; Tomoda, Haruo [Tokai Univ., Isehara, Kanagawa (Japan). School of Medicine; Sugihara, Masami

    1983-05-01

    The extent of Tl-201 perfusion defects was determined in three views by the average ratio of perfusion defects to that of the left ventricle. As the percent Tl-201 defect index increased, the peak value of creatine phosphokinase, the grade of Peel index, incidence of congestion on the initial chest X-ray, and pulmonary artery end-diastolic pressure all gradually increased. In 48 patients followed for 23 months on the average after discharge, the incidence of congestive heart failure and ventricular premature beat also increased. The prognosis was particulary poor in patients who had the percent Tl-201 defect index greater than 40%.

  3. Myocardial infarction, androgen and the skin.

    Science.gov (United States)

    Halim, M M; Meyrick, G; Jeans, W D; Murphy, D; Burton, J L

    1978-01-01

    Various indices of masculinity were compared in 48 men who had recovered from myocardial infarction and in their age-matched controls. We found little evidence to support the idea that myocardial infarction is related to increased androgenic stimulation. The patients with myocardial infarction had no increase in plasma testosterone, muscle thickness, sebum excretion rate, maximal sweat secretion rate, male pattern alopecia or density of terminal body hair, but as a group they had a slight increase in skin and bone thickness compared with the controls.

  4. Antimony Doped Tin Oxides and Their Composites with Tin pyrophosphates as Catalyst Supports for Oxygen Evolution Reaction in Proton Exchange Membrane Water Electrolysis

    DEFF Research Database (Denmark)

    Xu, Junyuan; Li, Qingfeng; Christensen, Erik

    2012-01-01

    Proton exchange membrane water electrolysers operating at typically 80 °C or at further elevated temperatures suffer from insufficient catalyst activity and durability. In this work, antimony doped tin oxide nanoparticles were synthesized and further doped with an inorganic proton conducting phase...... based on tin pyrophosphates as the catalyst support. The materials showed an overall conductivity of 0.57 S cm−1 at 130 °C under the water vapor atmosphere with a contribution of the proton conduction. Using this composite support, iridium oxide nanoparticle catalysts were prepared and characterized...

  5. Inhibition of photosynthesis in isolated spinach chloroplasts by inorganic phosphate or inorganic pyrophosphatase in the presence of pyrophosphate and magnesium ions

    Energy Technology Data Exchange (ETDEWEB)

    Levine, G; Bassham, J A

    1974-01-01

    Inhibition of photosynthesis in isolated spinach chloroplasts by P/sub i/ is decreased by the presence of PP/sub i/ and increased with increasing Mg/sup 2 +/ concentration. Previously reported regulation of this photosynthesis by protein factors from spinach leaves appears to be due mostly to pyrophosphate phosphohydrolase (EC 3.6.1.1) activity which converts PP/sub i/ to P/sub i/ and to the effects of PP/sub i/ and Mg/sup 2 +/ on this pyrophosphatase activity.

  6. Analysis of the cardiac motion in myocardial infarction by the ECG-synchronized CT

    International Nuclear Information System (INIS)

    Watanabe, Shigeru; Shimizu, Masahiko; Yoshida, Hideo; Morooka, Nobuhiro; Shukuya, Masaki

    1981-01-01

    The cardiac motion in patients with myocardial infarction was analyzed by the ECG-synchronized computed tomography (CT). For ECG synchronization, the ECG gating method and the data sorting method were used. By the ECG gating method, the gated cardiac images during 0.1 msec intervals at end-diastolic and the end-systolic phases were obtained. By the data sorting method, phasic CT images were reconstructed retrospectively by selecting appropriate data from a series of consecutive scans taken with simultaneous continuous ECG recordings. Six normal subjects and eight patients with myocardial infarction were studied by the ECG gating method, and 14 normal subjects and 25 patients with myocardial infarction were studied by the data sorting method. The end-diastolic and the end-systolic pictures at mid left ventricular level were superimposed and the cardiac borders were traced for the analysis (Fig. 4). Then the cardiac cross-sectional areas at each cardiac phase (40 msec) were calculated, and a cardiac area curve was obtained by plotting them consecutively. The cross-sectional images were divided into right anterior, right posterior, left anterior and left posterior segments. Cardiac area curves of the each segment were also obtained for further analysis. From these curves, the changing ratio of cardiac areas (maximum area - minimum area/maximum area) and the maximum area velocity in systole and diastole were calculated. On the images and the cardiac area curves in myocardial infarction patients, abnormal myocardial movements such as partial akinesis, hypokinesis or paradoxical movement were apparent asd the area of abnormal motions corresponded well with the location of infarction determined by ECG, RI scanning and angiography. A decrease of the changing ratio and the velocity in the infarction area were shown (Fig. 6, 7) and the functional disturbances were suggested during not only systole but diastole also. (author)

  7. Exercise-induced ST-T changes and severity of myocardial ischemia in single-vessel coronary artery disease

    International Nuclear Information System (INIS)

    Shimonagata, Tsuyoshi; Nishimura, Tsunehiko; Uehara, Toshiisa; Hayashida, Kohei; Takamiya, Makoto; Sumiyoshi, Tetsuya; Saito, Muneyasu.

    1986-01-01

    The purpose of this study was to evaluate how exercise-induced ST-T changes reflect the severity of myocardial ischemia in 66 patients with singlevessel disease (SVD) who underwent stress thallium scans. Quantitative assessment of myocardial ischemia was performed with thallium ischemic score (TIS) derived from circumferential profile analysis. Circumferential profiles of the initial and 4 hr redistribution myocardial image were generated for each of three views (ANT, LAO 45, LAO 70) and TIS was obtained as the average of the area between the initial and 4 hr redistribution profile for each view. In 66 patients with SVD, TIS were compared with coronary angiographic findings. TIS was correlated well with the severity of coronary artery stenosis. In addition, TIS was also correlated well with lung thallium uptake in 46 LAD disease. Therefore, these data proved that TIS was useful for the evaluation of the severity of myocardial ischemia. In 46 LAD disease, TIS, being as the indicator of the severity of myocardial ischemia, was compared precisely with results of stress electrocardiograms to evaluate how exercise-induced ST-T changes reflect the severity of myocardial ischemia. Patients with negative U wave had the highest mean TIS and those with horizontal or down sloping ST depression of 1.0 mm or more had higher mean TIS than those with slow upsloping ST depression of 1.5 mm or more, but there were no significant differences between these groups and those without ST-T change and the mean TIS was not different significantly between V 2-6 ST depression group and V 2-6 , II, III, a V F ST depression group. In conclusion, these results indicated that exercise-induced ST-T changes reflect the severity of myocardial ischemia in some degree but also has a limitation in evaluation of the severity of myocardial ischemia. (author)

  8. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine ( ... for each thyroid uptake is five minutes or less. top of page What will I experience during ...

  9. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... evaluate changes in the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should ... such as an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the ...

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... abnormal was found, and should not be a cause of concern for you. If you had an ... abnormal was found, and should not be a cause of concern for you. Actual scanning time for ...

  11. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to a multiplexer slip ring means for receiving output from the detectors and enabling interfeed to the image reconstruction station. (U.K.)

  12. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are presented of a tomographic scanning apparatus, its rotational assembly, and the control and circuit elements, with particular reference to the amplifier and multiplexing circuits enabling detector signal calibration. (U.K.)

  13. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification relates to a tomographic scanning apparatus using a fan beam and digital output signal, and particularly to the design of the gas-pressurized ionization detection system. (U.K.)

  14. Pediatric CT Scans

    Science.gov (United States)

    The Radiation Epidemiology Branch and collaborators have initiated a retrospective cohort study to evaluate the relationship between radiation exposure from CT scans conducted during childhood and adolescence and the subsequent development of cancer.

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... which are encased in metal and plastic and most often shaped like a box, attached to a ... will I experience during and after the procedure? Most thyroid scan and thyroid uptake procedures are painless. ...

  16. Heart CT scan

    Science.gov (United States)

    ... make to decrease the risk of heart disease. Risks Risks of CT scans include: Being exposed to ... urac.org). URAC's accreditation program is an independent audit to verify that A.D.A.M. follows ...

  17. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... eat for several hours before your exam because eating can affect the accuracy of the uptake measurement. ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information ...

  18. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) is ... thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that uses ...

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... that help physicians diagnose and evaluate medical conditions. These imaging scans use radioactive materials called radiopharmaceuticals or ... or had thyroid cancer. A physician may perform these imaging tests to: determine if the gland is ...

  20. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Because nuclear medicine procedures are able to pinpoint molecular activity within the body, they offer the potential ... or imaging device that produces pictures and provides molecular information. The thyroid scan and thyroid uptake provide ...

  1. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Actual scanning time for each thyroid uptake is five minutes or less. top of page What will ... diagnostic procedures have been used for more than five decades, and there are no known long-term ...

  2. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... top of page Additional Information and Resources RTAnswers.org Radiation Therapy for Head and Neck Cancer top ... Scan and Uptake Sponsored by Please note RadiologyInfo.org is not a medical facility. Please contact your ...

  3. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... often unattainable using other imaging procedures. For many diseases, nuclear medicine scans yield the most useful information needed to make a diagnosis or to determine appropriate treatment, if any. Nuclear medicine is less expensive and ...

  4. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gamma camera and single-photon emission-computed tomography (SPECT). The gamma camera, also called a scintillation ... high as with other imaging techniques, such as CT or MRI. However, nuclear medicine scans are more ...

  5. Scanning Auger Electron Microscope

    Data.gov (United States)

    Federal Laboratory Consortium — A JEOL model 7830F field emission source, scanning Auger microscope.Specifications / Capabilities:Ultra-high vacuum (UHV), electron gun range from 0.1 kV to 25 kV,...

  6. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... as an overactive thyroid gland, a condition called hyperthyroidism , cancer or other growths assess the nature of ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two ...

  7. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... painless. However, during the thyroid scan, you may feel uncomfortable when lying completely still with your head ... When the radiotracer is given intravenously, you will feel a slight pin prick when the needle is ...

  8. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... energy. top of page What are some common uses of the procedure? The thyroid scan is used ... community, you can search the ACR-accredited facilities database . This website does not provide cost information. The ...

  9. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is ... computer, create pictures offering details on both the structure and function of organs and tissues in your ...

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... found, and should not be a cause of concern for you. If you had an intravenous line ... found, and should not be a cause of concern for you. Actual scanning time for each thyroid ...

  11. Body CT (CAT Scan)

    Science.gov (United States)

    ... a CT scan can be reformatted in multiple planes, and can even generate three-dimensional images. These ... other medical conditions and whether you have a history of heart disease, asthma, diabetes, kidney disease or ...

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... You will receive specific instructions based on the type of scan you are undergoing. top of page ...

  13. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... Uptake? A thyroid scan is a type of nuclear medicine imaging. The radioactive iodine uptake test (RAIU) ... of thyroid function, but does not involve imaging. Nuclear medicine is a branch of medical imaging that ...

  14. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    This patent specification describes a tomographic scanning apparatus, with particular reference to the adjustable fan beam and its collimator system, together with the facility for taking a conventional x-radiograph without moving the patient. (U.K.)

  15. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... exam of any medications you are taking, including vitamins and herbal supplements. You should also inform them ... of scan you are undergoing. top of page What does the equipment look like? The special camera ...

  16. The Scanning Optical Microscope.

    Science.gov (United States)

    Sheppard, C. J. R.

    1978-01-01

    Describes the principle of the scanning optical microscope and explains its advantages over the conventional microscope in the improvement of resolution and contrast, as well as the possibility of producing a picture from optical harmonies generated within the specimen.

  17. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... the gland following medication use, surgery, radiotherapy or chemotherapy top of page How should I prepare? You ... but is often performed on hospitalized patients as well. Thyroid Scan You will be positioned on an ...

  18. Simultaneous /sup 201/Tl//sup 99m/Tc seven-pinhole tomography in acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Krause, T; Schuemichen, C; Fischer, R; Strauss, E; Hoffmann, G

    1986-06-01

    Combined infarction scintigraphy with /sup 201/Tl-chloride and /sup 99m/Tc-pyrophosphate (PPi) by simultaneous seven-pinhole tomography was investigated with a phantom as well as in patients. No artificial defects occurred when the collimator was centered correctly in axial position, but a very high standard of image uniformity and linearity of the gamma camera was required. Artefacts by overlying activity from the skeleton or cardiac blood pool were not observed. All 11 controls showed normal results. Despite a poor depth resolution due to limitations of the system even small areas of partially damaged myocardium could be recognized and correlated three-dimensionally. Of 24 patients with proven myocardial infarction, in 16 both a positive (/sup 99m/Tc-PPi) and a negative (/sup 201/Tl) image was obtained in congruence with the necrosis. 8 patients (33%) showed discordant results providing however additional information on the nature and extent of the necrosis. 4 out of 6 non-transmural infarctions seen by tomography had been suspected clinically.

  19. Observations of super early left ventricular remodeling experimental myocardial infarction

    International Nuclear Information System (INIS)

    Zhang, C.G.; Jin, J.H.; Zhao, X.B.; Kang, C.S.; Liang, F.Y.; Yin, Z.M.; Liu, G.F.; Li, S.J.; Li, X.F.; Hu, G.; Qin, D.Z.; Song, L.Z.

    2004-01-01

    Purpose: Ventricular remodeling is defined as the changes in the shape and size of the entire left ventricle after acute myocardial infarction (AMI). Many investigators have shown that left ventricular remodeling is related to clinical outcomes, including mortality, that represent the natural history, of the heart failure syndrome. The aim of this study was to demonstrate that it is possible to observe super early left ventricular remodeling by 99mTc-MIBI myocardial imaging in the dog model of acute experimental myocardial infarction. Methods: Experimental subjects: Twenty-three healthy mongrel dogs (14-25 kg) of either sex were studied under general anesthesia (sodium pentobarbital, 30 mg/kg). The left anterior descending (LAD) coronary artery was dissected and ligated between the first and second diagonal branches. Seven dogs died of ventricular fibrillation after the LAD coronary artery ligation. The 16 remaining dogs were divided into two groups: Group A (GA) received 99mTc-MIBI myocardial imaging (n=8): Group B (GB) received 99mTc-MIBI myocardial imaging combined with echocardiography (n=8). 99mTc-MIBI myocardial perfusion imaging :Static 99mTc-MIBI myocardial imaging was taken with ADAC Vertex Dual-head SPECT. 99mTc-MIBI kit was manufactured in Syncor, China. Each dog served as its own control, and was scanned by 99mTc-MIBI myocardial imaging and chocardiography at 48-72 hours before ligation. The mean time of the first acquisition was 21.87 ± 11.03 (14-48) minutes post-operatively in GA, 57.63±22.83 (30-99) minutes for 99mTc-MIBI imaging in GB, 26.00±15.07 (12-50) minutes for echocardiography in GB. Acquisition techniques for Gated SPECT: ECG synchronized data collection: R wave trigger, 8 Frames/Cardiac cycle. Images were gathered by rotating the detectors 180 degrees at 6 degrees per frame. Each frame took 40 seconds. The dog position was supine. The images were acquired and recorded for 6 hours following the LAD coronary artery ligation. After 6 hours

  20. The clinical application value of myocardial perfusion imaging in evaluating coronary artery myocardial bridge patients with symptoms

    International Nuclear Information System (INIS)

    Wang Yuetao; Fu Ning; Ding Xuemei; Lu Cunzhi; Zhu Feng; Wang Guanmin; Huang Yijie; Wang Linguang

    2008-01-01

    Objective: Myocardial bridge is a common inborn coronary artery anomaly, myocardial bridge may be associated with myocardial ischemia. Only a few patients with coronary artery myocardial bridge were evaluated with nuclear medicine techniques. The aim of this study was to investigate the role of nuclear cardiology with myocardial perfusion technique in symptomatic myocardial bridge patients. Methods Nineteen myocardial bridge patients with the symptoms of chest pain and chest distress were analyzed retrospectively. 99 Tc m -methoxyisobutylisonitrile (MIBI) myocardial perfusion images (both exercise and rest) were performed in all. Imaging results were compared with the results of movement electrocardiogram (ECG) and coronary arteriography. The t test or χ 2 test was used to statistically analyze the data with Stata 7.0 software. Results: Of the 19 patients, 18 patients had myocardial bridge locating at the left anterior descending artery, 1 patient at the left anterior descending and left circumflex artery, the mean angiographic systolic occlusion within the myocardial bridge was (65.4 ± 22.1)%. Of these 19 patients, Exercise-rest 99 Tc m -MIBI myocardial perfusion imaging defined positive myocardial ischemia in 10 and negative in 9 patients. Of the 10 patients with 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia, 8 had reversible radioactive defect of partial anterior wall and (or) apex, 1 had reversible defect of post lateral wall and post septal wall, and 1 had reversible defect of inferior wall. The positive predictive value of myocardial perfusion imaging was 52.6% (10/19), which was higher than movement ECG [21.1% (4/19), χ 2 = 4.07, P 99 Tc m -MIBI myocardial periusion imaging defined myocardial ischemia. Six cases with Grade II stenosis, two were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial ischemia. Eight cases with Grade III stenosis, seven were 99 Tc m -MIBI myocardial perfusion imaging defined myocardial

  1. Quantitative aspects of myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Vogel, R.A.

    1980-01-01

    Myocardial perfusion measurements have traditionally been performed in a quantitative fashion using application of the Sapirstein, Fick, Kety-Schmidt, or compartmental analysis principles. Although global myocardial blood flow measurements have not proven clinically useful, regional determinations have substantially advanced our understanding of and ability to detect myocardial ischemia. With the introduction of thallium-201, such studies have become widely available, although these have generally undergone qualitative evaluation. Using computer-digitized data, several methods for the quantification of myocardial perfusion images have been introduced. These include orthogonal and polar coordinate systems and anatomically oriented region of interest segmentation. Statistical ranges of normal and time-activity analyses have been applied to these data, resulting in objective and reproducible means of data evaluation

  2. Myocardial perfusion scintigraphy - possibilities of diagnosing CAD

    International Nuclear Information System (INIS)

    Tsonevska, A.

    1998-01-01

    A reviewing the diagnostic methods used in the intricate process of evaluating CAD patients in a attempt to establish the role played by radionuclide methods in the diagnostic strategy is done. The perfusion cardiotropic radiopharmaceuticals used and the various methods of evaluating myocardial are discussed. Although 210 Tl-chloride is the most widely used myocardial perfusion agent, recently 99m Tc-MIBI is proposed as an alternative because of its advantages. Myocardial perfusion assessment is done by various techniques depending on the specific aim, each of them having its proper advantages and shortcomings. The inference is reached that regardless of the routine practical implementation of myocardial perfusion scintigraphy and comprehensive studies along this line in course, there are problems still not well enough clarified awaiting solution

  3. The Pathogenesis of Human Myocardial Infarction

    Science.gov (United States)

    Rona, George

    1966-01-01

    Coronary arteriography, dissection of the coronary arteries and histopathological examination of the heart were carried out in 150 autopsies to study the effect of coronary narrowing and occlusion, of the presence of collaterals, and of coronary artery predominance on the development of myocardial infarction. The thrombosis rate was related to the severity of coronary sclerosis. The development of collaterals was not enhanced by coronary sclerosis and occlusion, and collaterals did not protect the myocardium against reinfarction. Coronary occlusion was regularly demonstrable in recent myocardial infarct cases. The association of atrial and posterior ventricular infarcts was explained by occlusion of their common arterial branch. The interdependence between coronary sclerosis, thrombosis and myocardial infarction in human autopsy material emphasizes the importance of mural coronary artery disease in the genesis of coronary occlusion and myocardial infarction, and it is at variance with statistical data and experimental results. ImagesFig. 1Fig. 2Fig. 3Fig. 4Fig. 5Fig. 6 PMID:5924947

  4. DEPRESSIVE DISORDERS IN PATIENTS AFTER MYOCARDIAL INFARCTION

    OpenAIRE

    MUXAMADIYEVA NIGINA BAKHODIROVNA

    2016-01-01

    In article the depressions arising at patients after a myocardial infarction (MI) are shined, necessity of overcoming stigma concerning weight of the transferred MI, rational under-standing of illness especially in early period of the post infraction is defined.

  5. Intracranial hemorrhage complicating thrombolytic therapy for acute myocardial infarction

    International Nuclear Information System (INIS)

    Uglietta, J.P.; Boyko, O.B.; O'Connor, C.M.; Aldrich, H.; Massey, E.W.; Heinz, E.R.

    1990-01-01

    This paper determines the incidence and types of intracranial hemorrhage (ICH) in 1,696 patients treated with thrombolytic therapy for acute myocardial infarction (AMI). Thirteen of 1,696 patients experienced ICH, and their nonenhanced brain CT scans were reviewed. Their mean age was 62 years (range, 53-74 years), and nine of 13 were male. Six patients received tissue plasminogen activator (tPA), four streptokinase, two urokinase, and one tPA and urokinase. The hemorrhages were classified according to CT location: intraparenchymal (IPH), subarachnoid (SAH), subdural (SDH), and intraventricular (IVH). The incidence of ICH was 0.76%. There were 31 hemorrhages in 13 patients. Twelve hemorrhages were IPH, 10 were SDH, seven were SAH, and two were IVH. Excluding IVH, 24 of 29 hemorrhages (83%) were supratentorial

  6. Echocardiography diagnosis of myocardial infarction complications

    Directory of Open Access Journals (Sweden)

    N.D. Oryshchyn

    2016-03-01

    Full Text Available Diagnosis and management of myocardial infarction complications are discussed in this article. These complications are associated with high level of mortality and surgery is a main treatment method. High level of suspicion and early diagnosis are essential for appropriate treatment and improvement of prognosis. Echocardiography is a main diagnostic method. Analysis of literature about contemporary management of mechanical complications of myocardial infarction has been performed, case reports are presented.

  7. Acute myocardial infarction: 'telomerasing' for cardioprotection

    OpenAIRE

    Sanchís-Gomar, Fabián; Lucía Mulas, Alejandro

    2015-01-01

    Reactivating the telomerase gene through gene therapy after acute myocardial infarction (AMI) has been recently reported to improve survival in mice. Given that regular physical exercise also activates this gene, therapeutic and lifestyle interventions targeting telomerase need to be explored as possible additions to the current armamentarium for myocardial regeneration. 9.292 JCR (2015) Q1, 17/289 Biochemistry & mollecular biology, 17/187 Cell biology, 8/124 Medicine, research & experimen...

  8. Improved exercise myocardial perfusion during lidoflazine therapy

    International Nuclear Information System (INIS)

    Shapiro, W.; Narahara, K.A.; Park, J.

    1983-01-01

    Lidoflazine is a synthetic drug with calcium-channel blocking effects. In a study of 6 patients with severe classic angina pectoris, single-blind administration of lidoflazine was associated with improved myocardial perfusion during exercise as determined by thallium-201 stress scintigraphy. These studies demonstrate that lidoflazine therapy is associated with relief of angina, an increased physical work capacity, and improved regional myocardial perfusion during exercise

  9. Measurement of myocardial perfusion using magnetic resonance

    DEFF Research Database (Denmark)

    Fritz-Hansen, T.; Jensen, L.T.; Larsson, H.B.

    2008-01-01

    Cardiac magnetic resonance imaging (MRI) has evolved rapidly. Recent developments have made non-invasive quantitative myocardial perfusion measurements possible. MRI is particularly attractive due to its high spatial resolution and because it does not involve ionising radiation. This paper reviews...... myocardial perfusion imaging with MR contrast agents: methods, validation and experiences from clinical studies. Unresolved issues still restrict the use of these techniques to research although clinical applications are within reach Udgivelsesdato: 2008/12/8...

  10. Quantitative myocardial perfusion from static cardiac and dynamic arterial CT

    Science.gov (United States)

    Bindschadler, Michael; Branch, Kelley R.; Alessio, Adam M.

    2018-05-01

    Quantitative myocardial blood flow (MBF) estimation by dynamic contrast enhanced cardiac computed tomography (CT) requires multi-frame acquisition of contrast transit through the blood pool and myocardium to inform the arterial input and tissue response functions. Both the input and the tissue response functions for the entire myocardium are sampled with each acquisition. However, the long breath holds and frequent sampling can result in significant motion artifacts and relatively high radiation dose. To address these limitations, we propose and evaluate a new static cardiac and dynamic arterial (SCDA) quantitative MBF approach where (1) the input function is well sampled using either prediction from pre-scan timing bolus data or measured from dynamic thin slice ‘bolus tracking’ acquisitions, and (2) the whole-heart tissue response data is limited to one contrast enhanced CT acquisition. A perfusion model uses the dynamic arterial input function to generate a family of possible myocardial contrast enhancement curves corresponding to a range of MBF values. Combined with the timing of the single whole-heart acquisition, these curves generate a lookup table relating myocardial contrast enhancement to quantitative MBF. We tested the SCDA approach in 28 patients that underwent a full dynamic CT protocol both at rest and vasodilator stress conditions. Using measured input function plus single (enhanced CT only) or plus double (enhanced and contrast free baseline CT’s) myocardial acquisitions yielded MBF estimates with root mean square (RMS) error of 1.2 ml/min/g and 0.35 ml/min/g, and radiation dose reductions of 90% and 83%, respectively. The prediction of the input function based on timing bolus data and the static acquisition had an RMS error compared to the measured input function of 26.0% which led to MBF estimation errors greater than threefold higher than using the measured input function. SCDA presents a new, simplified approach for quantitative

  11. Automated quantitative coronary computed tomography correlates of myocardial ischaemia on gated myocardial perfusion SPECT

    International Nuclear Information System (INIS)

    Graaf, Michiel A. de; Boogers, Mark J.; Veltman, Caroline E.; El-Naggar, Heba M.; Bax, Jeroen J.; Delgado, Victoria; Broersen, Alexander; Kitslaar, Pieter H.; Dijkstra, Jouke; Kroft, Lucia J.; Younis, Imad Al; Reiber, Johan H.; Scholte, Arthur J.

    2013-01-01

    Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. Myocardial ischaemia was seen in 25 patients (62.5 %) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95 % CI 2.41-24.7, p 2 = 20.7) and lesion length (χ 2 = 26.0) to the clinical variables and the visual assessment (χ 2 = 5.9) had incremental value in the association with myocardial ischaemia. Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia. (orig.)

  12. Myocardial infarction in Swedish subway drivers.

    Science.gov (United States)

    Bigert, Carolina; Klerdal, Kristina; Hammar, Niklas; Gustavsson, Per

    2007-08-01

    Particulate matter in urban air is associated with the risk of myocardial infarction in the general population. Very high levels of airborne particles have been detected in the subway system of Stockholm, as well as in several other large cities. This situation has caused concern for negative health effects among subway staff. The aim of this study was to investigate whether there is an increased incidence of myocardial infarction among subway drivers. Data from a population-based case-control study of men aged 40-69 in Stockholm County in 1976-1996 were used. The study included all first events of myocardial infarction in registers of hospital discharges and deaths. The controls were selected randomly from the general population. National censuses were used for information on occupation. Altogether, 22 311 cases and 131 496 controls were included. Among these, 54 cases and 250 controls had worked as subway drivers. The relative risk of myocardial infarction among subway drivers was not increased. It was 0.92 [95% confidence interval (95% CI) 0.68-1.25] when the subway drivers were compared with other manual workers and 1.06 (95% CI 0.78-1.43) when the subway drivers were compared with all other gainfully employed men. Subgroup analyses indicated no influence on the risk of myocardial infarction from the duration of employment, latency time, or time since employment stopped. Subway drivers in Stockholm do not have a higher incidence of myocardial infarction than other employed persons.

  13. Comprehensive Cardiovascular magnetic resonance of myocardial mechanics in mice using three-dimensional cine DENSE

    Science.gov (United States)

    2011-01-01

    Background Quantitative noninvasive imaging of myocardial mechanics in mice enables studies of the roles of individual genes in cardiac function. We sought to develop comprehensive three-dimensional methods for imaging myocardial mechanics in mice. Methods A 3D cine DENSE pulse sequence was implemented on a 7T small-bore scanner. The sequence used three-point phase cycling for artifact suppression and a stack-of-spirals k-space trajectory for efficient data acquisition. A semi-automatic 2D method was adapted for 3D image segmentation, and automated 3D methods to calculate strain, twist, and torsion were employed. A scan protocol that covered the majority of the left ventricle in a scan time of less than 25 minutes was developed, and seven healthy C57Bl/6 mice were studied. Results Using these methods, multiphase normal and shear strains were measured, as were myocardial twist and torsion. Peak end-systolic values for the normal strains at the mid-ventricular level were 0.29 ± 0.17, -0.13 ± 0.03, and -0.18 ± 0.14 for Err, Ecc, and Ell, respectively. Peak end-systolic values for the shear strains were 0.00 ± 0.08, 0.04 ± 0.12, and 0.03 ± 0.07 for Erc, Erl, and Ecl, respectively. The peak end-systolic normalized torsion was 5.6 ± 0.9°. Conclusions Using a 3D cine DENSE sequence tailored for cardiac imaging in mice at 7 T, a comprehensive assessment of 3D myocardial mechanics can be achieved with a scan time of less than 25 minutes and an image analysis time of approximately 1 hour. PMID:22208954

  14. Positron computed tomography for myocardial uptake of N-13 ammonia in patients with hypertrophic cardiomyopathy

    International Nuclear Information System (INIS)

    Yoshida, Katsuya; Himi, Toshiharu; Imai, Hitoshi; Shukuya, Masaki; Masuda, Yoshiaki; Inagaki, Yoshiaki; Yamasaki, Toshiro; Tateno, Yukio.

    1985-01-01

    In the present study, positron computed tomography (PCT) was used to evaluate the myocardial uptake of N-13 ammonia in patients with hypertrophic cardiomyopathy (HCM). Eight subjects including two normal persons, four patients with HCM, and two with old myocardial farction (OMI) were selected for the study. N-13 ammonia was administered intravenously as a bolus and, commencing with the tracer injection, serial 30-second PCT scans were performed. The results were summarized as follows: 1. The first scan exhibiting cardiac blood pool images revealed a reduced left ventricular cavity in the HCM subjects. 2. After clearance of N-13 from the cardiopulmonary vasculature, the left ventricular myocardium was clearly visualized and an increased myocardial mass with characteristic morphology was demonstrated in the HCM subjects. 3. Detailed analysis of the time-activity curves of the blood pool and myocardium derived from these serial scan images disclosed two uptake phases in the uptake mode of N-13 ammonia. In the initial phase within three minutes, the myocardial uptake of N-13 was rapid in the normal and OMI subjects, whereas its significant delay was observed in the HCM subjects. This may reflect an abnormal initial extraction of N-13 ammonia in the HCM patients compared with the other subjects. 4. Subsequently, in the second phase, which was characterized by a gradual increase of N-13 in the myocardium, the HCM subjects revealed higher uptake ratios than did the others. This may indicate an increased extraction of metabolites of N-13 ammonia during the second phase. These preliminary results undersore the usefulness of dynamic PCT with N-13 ammonia for the assessment of HCM. (author)

  15. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  16. Quantitative myocardial blood flow with Rubidium-82 PET

    DEFF Research Database (Denmark)

    Hagemann, Christoffer E; Ghotbi, Adam A; Kjær, Andreas

    2015-01-01

    Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1) identificat......Positron emission tomography (PET) allows assessment of myocardial blood flow in absolute terms (ml/min/g). Quantification of myocardial blood flow (MBF) and myocardial flow reserve (MFR) extend the scope of conventional semi-quantitative myocardial perfusion imaging (MPI): e.g. in 1...... global MFR and major adverse cardiovascular events (MACE), and together with new diagnostic possibilities from measuring the longitudinal myocardial perfusion gradient, cardiac (82)Rb PET faces a promising clinical future. This article reviews current evidence on quantitative (82)Rb PET's ability...

  17. Assessment of left ventricular function by electrocardiogram-gated myocardial single photon emission computed tomography using quantitative gated single photon emission computed tomography software

    International Nuclear Information System (INIS)

    Morita, Koichi; Adachi, Itaru; Konno, Masanori

    1999-01-01

    Electrocardiogram (ECG)-gated myocardial single photon emission computed tomography (SPECT) can assess left ventricular (LV) perfusion and function easily using quantitative gated SPECT (QGS) software. ECG-gated SPECT was performed in 44 patients with coronary artery disease under post-stress and resting conditions to assess the values of LV functional parameters, by comparison to LV ejection fraction derived from gated blood pool scan and myocardial characteristics. A good correlation was obtained between ejection fraction using QGS and that using cardiac blood pool scan (r=0.812). Some patients with myocardial ischemia had lower ejection fraction under post-stress compared to resting conditions, indicating post-stress LV dysfunction. LV wall motion and wall thickening were significantly impaired in ischemic and infarcted myocardium, and the degree of abnormality in the infarcted areas was greater than in the ischemia area. LV functional parameters derived using QGS were useful to assess post-stress LV dysfunction and myocardial viability. In conclusion, ECG-gated myocardial SPECT permits simultaneous quantitative assessment of myocardial perfusion and function. (author)

  18. Evaluation of radioactive potassium and its analogues for imaging myocardial infarcts

    International Nuclear Information System (INIS)

    Gorten, R.J.

    1977-01-01

    An extensive clinical evaluation was undertaken to assess the value of myocardial infarct imaging with radioactive potassium and analogues. Of 130 patients so examined, 80 were diagnosed as having suffered infarcts in the recent or distant past on the basis of all information other than the scan. The radionuclide imaging results were abnormal in 87.5 percent overall, 97 percent in acute transmural infarcts, and 83 percent in lesions over 3 weeks old. In 50 patients not considered to have had myocardial infarcts or contusions, apparently false abnormal results were obtained in 15 percent. These were all patients in whom additional diagnostic help was desired after the ordinary laboratory tests and electrocardiograms. Excellent agreement of infarct location was discovered on comparing radionuclide scans with radiographic contrast ventriculography. On comparing electrocardiograms with scans for infarct location, 85 percent complete or partial correlation was revealed. Agreement between scan abnormalities and significant-appearing coronary arteriographic lesions was rather poor, causing one to realize that 43 K scan abnormalities indicate regions of poor blood extraction by old or recent infarcts, rather than just poor regional arterial perfusion. While costly, radionuclide scans often provide worthwhile information about presence or absence of infarcts as well as about their location and size. Electrocardiograms and blood enzyme levels each cost less, but are almost always performed in serial fashion. This makes them actually more expensive than a single scan. Furthermore, a normal scan in a patient being considered for acute coronary care may be used as potent argument against the presence of an infarct, thereby saving costly intensive care and monitoring

  19. Stabilized-solubilized ferric pyrophosphate as a new iron source for food fortification. Bioavailability studies by means of the prophylactic-preventive method in rats.

    Science.gov (United States)

    Salgueiro, M J; Arnoldi, S; Kaliski, M A; Torti, H; Messeri, E; Weill, R; Zubillaga, M; Boccio, J

    2009-02-01

    The purpose of the present work was to evaluate the iron bioavailability of a new ferric pyrophosphate salt stabilized and solubilized with glycine. The prophylactic-preventive test in rats, using ferrous sulfate as the reference standard, was applied as the evaluating methodology both using water and yogurt as vehicles. Fifty female Sprague-Dawley rats weaned were randomized into five different groups (group 1: FeSO(4); group 2: pyr; group 3: FeSO(4) + yogurt; group 4: pyr + yogurt and group 5: control). The iron bioavailability (BioFe) of each compound was calculated using the formula proposed by Dutra-de-Oliveira et al. where BioFe % = (HbFef - HbFei) x 100/ToFeIn. Finally, the iron bioavailability results of each iron source were also given as relative biological value (RBV) using ferrous sulfate as the reference standard. The results showed that both BioFe % and RBV % of the new iron source tested is similar to that of the reference standard independently of the vehicle employed for the fortification procedure (FeSO(4) 49.46 +/- 12.0% and 100%; Pyr 52.66 +/- 15.02% and 106%; FeSO(4) + yogurth 54.39 +/- 13.92% and 110%; Pyr + yogurt 61.97 +/- 13.54% and 125%; Control 25.30 +/- 6.60, p soluble ferric pyrophosphate may be considered as an optimal iron source for food fortification.

  20. Segmental quantitative analysis of digital thallium-201 myocardial scintigrams in diagnosis of coronary artery disease

    International Nuclear Information System (INIS)

    Wainwright, R.J.; Maisey, M.N.; Sowton, E.

    1981-01-01

    One hundred and forty-nine patients with suspected ischaemic heart disease were evaluated by exercise thallium-201 myocardial scintigraphy ( 201 Tl SMS), single lead exercise electrocardiography, and coronary arteriography. Myocardial distribution of tracer was assessed semi-quantitatively from digital 201 Tl scintigrams and compared with tracer distribution in subjects with normal hearts. Fifty-two of 54 (96%) patients with normal coronary arteries had normal myocardial scintigrams whereas three patients had a positive ischaemic exercise electrocardiogram and were scan normal. Conversely, 36 of 95 (38%) patients with coronary artery disease had a positive ischaemic electrocardiogram compared with 94 of 95 (99%) patients who had a positive myocardial scintigram. Disease was predicted correctly in 76 out of 80 (95%) of left anterior descending coronary stenoses, in 48 out of 64 (75%) of right coronary artery stenoses, and in 55 out of 64 (85%) of left circumflex coronary artery stenoses, despite the presence of infarcted myocardium in other territories. 201 Tl SMS with segmental quantitative analysis is a highly sensitive and specific technique in the diagnosis of coronary artery disease and may be a useful screening procedure to select patients for further investigation, particularly those with evidence of life-threatening severe left coronary artery disease. (author)

  1. The relation between angina and myocardial ischemia during exercise stress in coronary artery disease

    International Nuclear Information System (INIS)

    Narita, Michihiro; Kurihara, Tadashi; Murano, Kenichi; Usami, Masahisa

    1988-01-01

    To examine the mechanism of occurrence of anginal chest pain from the aspect of myocardial ischemia, myocardial Tl-201 SPECT scans were obtained immediately and 3 hr after exercise (Ex) in 35 patients with coronary artery disease (CAD). The extent of ischemia was defined as the percentage of ischemic segments to the entire left ventricle. The minimum washout (WO) rate correlated well with the ratio of Tl uptake in the ischemic area to that in the normal area during Ex in the other 9 patients having single vessel CAD without previous history of myocardial infarction. This suggested that the miminum WO rate reflects the severity of Ex-induced ischemia. According to the development of angina during Ex, patients were classified as having either symptomatic ischemia (n = 16) or silent ischemia (n = 19). In regard to age, sex, a history of myocardial infarction, severity of CAD, and the extent of Ex-induced ischemia, there was no difference between the two groups. The minimum WO rate and the incidence of Ex-induced ST depression were significantly lower and higher, respectively, in the group with symptomatic ischemia than that with silent ischemia. The severity of Ex-induced ischemia has important implications for the development of anginal chest pain. (Namekawa, K.)

  2. Preoperative bone scans

    International Nuclear Information System (INIS)

    Charkes, N.D.; Malmud, L.S.; Caswell, T.; Goldman, L.; Hall, J.; Lauby, V.; Lightfoot, W.; Maier, W.; Rosemond, G.

    1975-01-01

    Strontium nitrate Sr-87m bone scans were made preoperatively in a group of women with suspected breast cancer, 35 of whom subsequently underwent radical mastectomy. In 3 of the 35 (9 percent), the scans were abnormal despite the absence of clinical or roentgenographic evidence of metastatic disease. All three patients had extensive axillary lymph node involvement by tumor, and went on to have additional bone metastases, from which one died. Roentgenograms failed to detect the metastases in all three. Occult bone metastases account in part for the failure of radical mastectomy to cure some patients with breast cancer. It is recommended that all candidates for radical mastectomy have a preoperative bone scan. (U.S.)

  3. Frequency scanning microstrip antennas

    DEFF Research Database (Denmark)

    Danielsen, Magnus; Jørgensen, Rolf

    1979-01-01

    The principles of using radiating microstrip resonators as elements in a frequency scanning antenna array are described. The resonators are cascade-coupled. This gives a scan of the main lobe due to the phase-shift in the resonator in addition to that created by the transmission line phase......-shift. Experimental results inX-band, in good agreement with the theory, show that it is possible to scan the main lobe an angle ofpm30degby a variation of the frequencypm300MHz, and where the 3 dB beamwidth is less than10deg. The directivity was 14.7 dB, while the gain was 8.1 dB. The efficiency might be improved...

  4. Myocardial adrenergic nerve activity in valvular diseases assessed by iodine-123-metaiodobenzylguanidine myocardial scintigraphy

    International Nuclear Information System (INIS)

    Imamura, Yoshihiro; Fukuyama, Takaya

    1997-01-01

    Iodine-123-metaiodobenzylguanidine (MIBG) imaging was used to assess myocardial adrenergic nerve activity in patients with heart failure. MIBG planar images were obtained in 94 patients. The uptake of MIBG, calculated as the heart-to-mediastinum activity ratio in the immediate image (15 min), showed a significant decrease only in patients with severe heart failure due to cardiomyopathy, but was not changed in those with valvular diseases. Storage and release of MIBG, calculated as the percentage myocardial MIBG washout from 15 min to 4 hours after isotope injection, was substantially accelerated in both patients with cardiomyopathy and valvular diseases in proportion to the severity of heart failure. These data suggest that, in severe heart failure associated with cardiomyopathy, norepinephrine uptake is reduced. Also, myocardial adrenergic nerve activity is accelerated in proportion to the severity of heart failure independent of the underlying cause. MIBG images were analyzed in 20 patients with mitral stenosis with the same methods to clarify whether myocardial adrenergic nerve activity is different in patients with heart failure without left ventricular volume or pressure overload. Myocardial uptake of MIBG did not show any significant difference. The percentage myocardial MIBG washout was increased in patients with severe heart failure. The closest correlation was between myocardial washout and cardiac output. In heart failure due to mitral stenosis, myocardial adrenergic nerve activity is intensified. Decrease in cardiac output associated with mitral stenosis acts as a potent stimulus for this intensification. (author)

  5. The diagnosis of silent myocardial ischemia. Motion-Frozen (or morphing) myocardial perfusion imaging.

    Science.gov (United States)

    Chang, Cheng; Ye, Bo; Xie, Wenhui; Zhang, Daoliang; Lei, Bei; Ye, Xiaodan

    2016-01-01

    Silent myocardial ischemia is typically defined as objective evidence of myocardial ischemia in patients without subjective ischemia symptoms. Currently, coronary artery angiography is the gold standard for diagnosis of asymptomatic coronary artery disease (CAD). Computed tomography coronary angiography (CTCA) can visually demonstrate the morphology, trend and extent of coronary stenosis and is commonly used in clinical screening of CAD. Myocardial perfusion imaging can be used not only to identify whether anatomical stenosis causes myocardial dysfunction, but to also assess the risk stratification and prognosis of myocardial disease (MD). Myocardial perfusion imaging using morphing combined with CTCA can simultaneously show the relationship between CAD and myocardial ischemia from an anatomical and functional aspect. This allows earlier diagnosis of asymptomatic CAD myocardial ischemia, accurate identification of the culprit vessels, and could prevent unnecessary interventional therapy. The 1-day dobutamine stress/resting met-hod is also one of the methods used. The combination of CTCA and the morphing technique can provide anatomical and functional information on coronary arteries at the same time, significantly improving the diagnostic sensitivity, specificity, and accuracy of MD.

  6. Value of the Doppler index of myocardial performance in the early phase of acute myocardial infarction

    DEFF Research Database (Denmark)

    Poulsen, S H; Jensen, S E; Tei, C

    2000-01-01

    Prospective assessment of a nongeometric Doppler-derived index of combined systolic and diastolic myocardial performance was performed in 64 patients with acute myocardial infarction (MI) within 1 hour after their arrival to the hospital and in 39 age-matched healthy subjects. The index is defined...

  7. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    Abele, M.

    1983-01-01

    A computerized tomographic scanning apparatus suitable for diagnosis and for improving target identification in stereotactic neurosurgery is described. It consists of a base, a source of penetrating energy, a detector which produces scanning signals and detector positioning means. A frame with top and bottom arms secures the detector and source to the top and bottom arms respectively. A drive mechanism rotates the frame about an axis along which the frame may also be moved. Finally, the detector may be moved relative to the bottom arm in a direction contrary to the rotation of the frame. (U.K.)

  8. Scanning the phenomenological MSSM

    CERN Document Server

    Wuerzinger, Jonas

    2017-01-01

    A framework to perform scans in the 19-dimensional phenomenological MSSM is developed and used to re-evaluate the ATLAS experiments' sensitivity to R-parity-conserving supersymmetry with LHC Run 2 data ($\\sqrt{s}=13$ TeV), using results from 14 separate ATLAS searches. We perform a $\\tilde{t}_1$ dedicated scan, only considering models with $m_{\\tilde{t}_1}<1$ TeV, while allowing both a neutralino ($\\tilde{\\chi}_1^0$) and a sneutrino ($\\tilde{\

  9. Calibration of scanning Lidar

    DEFF Research Database (Denmark)

    Gómez Arranz, Paula; Courtney, Michael

    This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast. Additio......This report describes the tests carried out on a scanning lidar at the DTU Test Station for large wind turbines, Høvsøre. The tests were divided in two parts. In the first part, the purpose was to obtain wind speed calibrations at two heights against two cup anemometers mounted on a mast...

  10. Adaptive Optical Scanning Holography

    Science.gov (United States)

    Tsang, P. W. M.; Poon, Ting-Chung; Liu, J.-P.

    2016-01-01

    Optical Scanning Holography (OSH) is a powerful technique that employs a single-pixel sensor and a row-by-row scanning mechanism to capture the hologram of a wide-view, three-dimensional object. However, the time required to acquire a hologram with OSH is rather lengthy. In this paper, we propose an enhanced framework, which is referred to as Adaptive OSH (AOSH), to shorten the holographic recording process. We have demonstrated that the AOSH method is capable of decreasing the acquisition time by up to an order of magnitude, while preserving the content of the hologram favorably. PMID:26916866

  11. Prognostic impact of physical activity prior to myocardial infarction

    DEFF Research Database (Denmark)

    Ejlersen, Hanne; Andersen, Zorana Jovanovic; von Euler-Chelpin, My Catarina

    2017-01-01

    the course of myocardial infarction by reducing case fatality and the subsequent risk of heart failure and mortality. Methods: A total of 14,223 participants in the Copenhagen City Heart Study were assessed at baseline in 1976-1978; 1,664 later developed myocardial infarction (mean age at myocardial...... estimated by logistic and Cox proportional hazards regression models, adjusted for age at myocardial infarction and other potential confounders. Results: A total of 425 (25.5%) myocardial infarctions were fatal. Higher levels of LTPA prior to myocardial infarction were associated with lower case fatality...

  12. Evaluation of myocardial involvement in Duchenne's progressive muscular dystrophy with thallium-201 myocardial perfusion imaging

    International Nuclear Information System (INIS)

    Kawai, Naoki; Sotobata, Iwao; Okada, Mitsuhiro

    1985-01-01

    Myocardial involvement in progressive muscular dystrophy of the Duchenne type was evaluated in 19 patients using thallium-201 myocardial perfusion imaging. A qualitative analysis was performed from five projection images by three experienced physicians. Distinct perfusion defects were shown in 13 patients, especially in the LV posterolateral or posterior wall (11 patients). There was no significant relationship between the presence of perfusion defects and the skeletal muscle involvements or thoracic deformities assessed by transmission computed tomography. Extensive perfusion defects were shown in 2 patients who died of congestive heart failure 1 to 2 years after the scintigraphic study. Progression of the myocardial scintigraphic abnormalities were considered to be minimal in 7 of 9 patients who underwent two serial scintigraphic studies over 2 to 3 years. It was concluded that thallium myocardial perfusion imaging is a useful clinical technique to assess myocardial involvement in Duchenne's progressive muscular dystrophy. (author)

  13. Localization and quantification of acute myocardial infarction by myocardial perfusion tomographic imaging

    International Nuclear Information System (INIS)

    Lin Xiufang; Min Changgeng; Lin Zhihu; Ke Ruoyi

    1994-01-01

    The authors reported the result of the quantification and localization of 30 clinically confirmed acute myocardial infarction patients in comparison with that of ECG. A left ventricle model was used to correct the area calculated by the method of Bull's eye. The result indicated that the infarction area calculated by the corrected Bull's eye method correlated closely with that determined by the ECG QRS scoring method (r = 0.706, P<0.01). Myocardial infarctions of all 30 patients were detected by both ECG and myocardial perfusion tomographic imaging. The accuracy of localization of myocardial infarction by myocardial perfusion imaging was similar to that of ECG in the anterior wall, anterior septum, anterior lateral and inferior wall, but superior to that of ECG in the apex, posterior lateral, posterior septum, and posterior wall

  14. Intracoronary thallium-201 scintigraphy after thrombolytic therapy for acute myocardial infarction compared with 10 and 100 day intravenous thallium-201 scintigraphy

    International Nuclear Information System (INIS)

    Heller, G.V.; Parker, J.A.; Silverman, K.J.; Royal, H.D.; Kolodny, G.M.; Paulin, S.; Braunwald, E.; Markis, J.E.

    1987-01-01

    Thallium-201 imaging has been utilized to estimate myocardial salvage after thrombolytic therapy for acute myocardial infarction. However, results from recent animal studies have suggested that as a result of reactive hyperemia and delayed necrosis, thallium-201 imaging may overestimate myocardial salvage. To determine whether early overestimation of salvage occurs in humans, intracoronary thallium-201 scans 1 hour after thrombolytic therapy were compared with intravenous thallium-201 scans obtained approximately 10 and 100 days after myocardial infarction in 29 patients. In 10 patients with angiographic evidence of coronary reperfusion, immediate improvement in thallium defects and no interim clinical events, there was no change in imaging in the follow-up studies. Of nine patients with coronary reperfusion but no initial improvement of perfusion defects, none showed worsening of defects in the follow-up images. Six of these patients demonstrated subsequent improvement at either 10 or 100 days after infarction. Seven of 10 patients with neither early evidence of reperfusion nor improvement in perfusion defects had improvement of infarct-related perfusion defects, and none showed worsening. In conclusion, serial scanning at 10 and 100 days after infarction in patients with no subsequent clinical events showed no worsening of the perfusion image compared with images obtained in acute studies. Therefore, there is no evidence that thallium-201 imaging performed early in patients with acute myocardial infarction overestimates improvement

  15. The relationship between myocardial blood flow and myocardial viability after reperfusion. Myocardial viability assessed by 15O-water-PET

    International Nuclear Information System (INIS)

    Tsukagoshi, Joichi

    1994-01-01

    The purpose of this study was to examine the relationship between myocardial blood flow and myocardial viability in the ischemic canine myocardium after reperfusion. Transient ischemia was induced by 60-, 90-, and 180-minute occlusion of the left anterior descending coronary artery. Myocardial blood flow (MBF) was measured in the areas in which regional contractility was severely impaired (ehocardiographically akinetic or dyskinetic) in the early reperfusion period by 15 O-water positron emission tomography (PET) 12 hours and 4 weeks after reperfusion. An MBF ratio of ischemic to nonischemic regions 12 hours after reperfusion was inversely correlated with the amount of histologically determined tissue necrosis (r=-0.74). The regional contractility recovered 4 weeks later in the areas where an MBF ratio was 0.48 or greater, but did not recover in the areas with a lower MBF ratio. Thus, myocardial viability can be appropriately predicted in the early phase of myocardial perfusion by PET with 15 O-water even in the absence of metabolic imaging. (author)

  16. [Genetic factors in myocardial infarction].

    Science.gov (United States)

    Hara, Masahiko; Sakata, Yasuhiko; Sato, Hiroshi

    2013-02-01

    One of the main mechanisms of acute myocardial infarction (AMI) is plaque rupture or erosion followed by intraluminal thrombus formation and occlusion of the coronary arteries. Thus far, many underlying conditions or environmental factors, such as hypertension, diabetes, dyslipidemia, smoking or obesity, as well as a family history of coronary artery diseases have been identified as risks for the onset of AMI. These risks suggest that AMI occurs due to interactions between underlying conditions and multiple genetic susceptibilities. For this reason, many target gene-disease association studies have been performed with the recent introduction of genome-wide association studies (GWAS) that have further revealed new genetic susceptibilities for AMI. GWAS is a way to examine many common genetic variants in different individuals to see if any variant is associated with a trait in a case-control fashion, and typically focuses on associations between single-nucleotide polymorphisms (SNP) and traits. SNP on chromosome 9p21 is one of the robust susceptibility variants for AMI which has been identified by many GWAS. In this review, we overview the methodology of GWAS, introduce genetic variants identified by GWAS as those with susceptibility for AMI, and describe the foresight of using GWAS to investigate genetic susceptibility to AMI.

  17. Tl myocardial SPECT demonstrates importance of collateral circulation in patients with myocardial infarction

    International Nuclear Information System (INIS)

    Hattori, Fukunori

    1997-01-01

    The influence of collateral circulation on the preservation of myocardial viability and the efficacy of drug therapy and PTCA were evaluated by exercise 201 Tl myocardial SPECT before and after treatment. Thirty-five patients with a history of myocardial infarction resulting from total or subtotal obstruction of the responsible coronary artery were divided into four groups, according to the method of the treatment and the degree of collateral blood flow. Patients in groups A and B received drug therapy and displayed developed and undeveloped collateral circulation, respectively. Groups C and D received PTCA and displayed developed and undeveloped collateral circulation, respectively. Tl myocardial SPECT was performed before treatment to record the extent of redistribution to the occluded region, the degree of myocardial viability and the nature and extent of the ischemic lesion. In group A, myocardial perfusion improved, although redistribution remained in all cases, while in group B, 4 of 7 cases improved after drug therapy. In group C, myocardial perfusion improved in all cases, and redistribution disappeared in 7 of 12 cases. 5 of 6 cases improved in group D after PTCA. After drug therapy, the %Tl uptake in the infarcted region improved significantly in initial and delayed images of patients in group A. The differences in initial and delayed images in group B before and after drug therapy were not significant. In contrast, groups C and D both registered significant improvement in initial and delayed images after PTCA. The washout rate improved significantly in groups A, C and D after their respective treatments. These results suggest that developed collateral circulation helps to preserve myocardial viability in cases of myocardial infarction. Myocardial perfusion improved after drug therapy in cases with developed collateral circulation, and in patients with developed and undeveloped collateral circulation receiving PTCA. (K.H.)

  18. Myocardial imaging in the noninvasive evaluation of patients with suspected ischemic heart disease

    International Nuclear Information System (INIS)

    Pitt, B.; Strauss, H.W.

    1976-01-01

    Three noninvasive radioactive tracer techniques for evaluating patients with ischemic heart disease are described: (1) myocardial perfusion imaging, (2) acute infarct imaging, and (3) the gated blood pool scan. Myocardial perfusion imaging with tracers that distribute in the myocardium in relation to regional blood flow allows detection of patients with transmural and nontransmural infarction by the finding of decreased tracer concentration in the affected region of the myocardium. If these tracers are injected at the time of maximal stress to patients with significant coronary arterial stenosis but without infarction, areas of transient ischemia can be identified as zones of decreased tracer concentration not found when an examination is performed at rest. Acute infarct imaging with tracers that localize in acutely damaged tissue permits separation of patients with acute myocardial necrosis from those without infarction and those with more chronic damage. The gated blood pool scan permits assessment of left ventricular function and regional wall motion. The measurement of ventricular volumes, ejection fraction and regional wall motion adds significantly to the determination of hemodynamic variables in assessing patients with acute infarction. The technique also permits detection of right ventricular dysfunction. Performance of a combination of these radioactive tracer techniques is often advantageous, particularly in patients with suspected infarction. The techniques can establish whether infarction is present, whether it is acute, where the damage is located and how extensive it is; they can also provide a measure of the effect of this damage on left ventricular function

  19. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... process that regulates the rate at which the body converts food to energy. top of page What are some common uses of the procedure? The thyroid scan is used to determine the size, shape and position of the thyroid gland. The ...

  20. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Thyroid Scan and Uptake ...

  1. Dialogue scanning measuring systems

    International Nuclear Information System (INIS)

    Borodyuk, V.P.; Shkundenkov, V.N.

    1985-01-01

    The main developments of scanning measuring systems intended for mass precision processsing of films in nuclear physics problems and in related fields are reviewed. A special attention is paid to the problem of creation of dialogue systems which permit to simlify the development of control computer software

  2. Scanning electron microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Cox, B. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1970-05-15

    The JSM-11 scanning electron microscope at CRNL has been used extensively for topographical studies of oxidized metals, fracture surfaces, entomological and biological specimens. A non-dispersive X-ray attachment permits the microanalysis of the surface features. Techniques for the production of electron channeling patterns have been developed. (author)

  3. Scanning tunneling microscopy

    International Nuclear Information System (INIS)

    Binnig, G.; Rohrer, H.

    1983-01-01

    Based on vacuum tunneling, a novel type of microscope, the scanning tunneling microscope (STM) was developed. It has an unprecedented resolution in real space on an atomic scale. The authors review the important technical features, illustrate the power of the STM for surface topographies and discuss its potential in other areas of science and technology. (Auth.)

  4. Bone scan in rheumatology

    International Nuclear Information System (INIS)

    Morales G, R.; Cano P, R.; Mendoza P, R.

    1993-01-01

    In this chapter a revision is made concerning different uses of bone scan in rheumatic diseases. These include reflex sympathetic dystrophy, osteomyelitis, spondyloarthropaties, metabolic bone diseases, avascular bone necrosis and bone injuries due to sports. There is as well some comments concerning pediatric pathology and orthopedics. (authors). 19 refs., 9 figs

  5. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... information. The thyroid scan and thyroid uptake provide information about the structure and function of the thyroid. The thyroid is a gland in the neck that controls metabolism , a chemical process that regulates the rate at which the body ...

  6. Tomographic scanning apparatus

    International Nuclear Information System (INIS)

    1981-01-01

    Details are given of a tomographic scanning apparatus, with particular reference to the means of adjusting the apparent gain of the signal processing means for receiving output signals from the detectors, to compensate for drift in the gain characteristics, including means for passing a reference signal. (U.K.)

  7. Stabilized radiographic scanning agent

    International Nuclear Information System (INIS)

    Fawzi, M.B.

    1979-01-01

    A stable composition useful in preparation of technetium-99m-based radiographic scanning agents has been developed. The composition contains a stabilizing amount of gentisate stabilizer selected from gentisic acid and its soluble pharmaceutically-acceptable salts and esthers. (E.G.)

  8. Scanning electron microscope

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    The principle underlying the design of the scanning electron microscope (SEM), the design and functioning of SEM are described. Its applications in the areas of microcircuitry and materials science are outlined. The development of SEM in India is reviewed. (M.G.B.)

  9. Radiographic scanning agent

    International Nuclear Information System (INIS)

    Tofe, A.J.

    1976-01-01

    A stable radiographic scanning agent on a sup(99m)Tc basis has been developed. The substance contains a pertechnetate reduction agent, tin(II)-chloride, chromium(II)-chloride, or iron(II)-sulphate, as well as an organospecific carrier and ascorbic acid or a pharmacologically admissible salt or ester of ascorbic acid. (VJ) [de

  10. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... you: have had any tests, such as an x-ray or CT scan, surgeries or treatments using iodinated ... page How does the procedure work? With ordinary x-ray examinations, an image is made by passing x- ...

  11. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... for a thyroid scan is 30 minutes or less. Thyroid Uptake You will be given radioactive iodine (I-123 or I-131) in liquid or capsule form to swallow. The thyroid uptake will begin several hours to 24 hours later. Often, two separate uptake ...

  12. Thyroid Scan and Uptake

    Medline Plus

    Full Text Available ... an x-ray or CT scan, surgeries or treatments using iodinated contrast material within the last two months. are taking medications or ingesting other substances that contain iodine , including kelp, seaweed, cough syrups, multivitamins or heart medications. have any ...

  13. Induction of a leaf specific geranylgeranyl pyrophosphate synthase and emission of (E,E)-4,8,12-trimethyltrideca-1,3,7,11-tetraene in tomato are dependent on both jasmonic acid and salicylic acid signaling pathways

    NARCIS (Netherlands)

    Ament, K.; Schie, C.C.; Bouwmeester, H.J.; Haring, M.A.; Schuurink, R.C.

    2006-01-01

    Two cDNAs encoding geranylgeranyl pyrophosphate (GGPP) synthases from tomato (Lycopersicon esculentum) have been cloned and functionally expressed in Escherichia coli. LeGGPS1 was predominantly expressed in leaf tissue and LeGGPS2 in ripening fruit and flower tissue. LeGGPS1 expression was induced

  14. Assessment of myocardial viability by MR imaging

    International Nuclear Information System (INIS)

    Sandstede, Joern J.W.

    2003-01-01

    Diagnosis of myocardial viability after infarction focuses on the prediction of functional improvement of dysfunctional myocardium after revascularization therapy. Magnetic resonance imaging provides different approaches for the detection of myocardial viability. Measurement of end-diastolic wall thickness is easy to perform and has a high sensitivity, but a low specificity, and can only be used 4 months after myocardial infarction due to infarct healing processes. Low-dose dobutamine stress has a good sensitivity with a high specificity for the prediction of wall motion improvement, but this is only true for patients with a singular dysfunctional area and only slightly depressed cardiac function. Late enhancement allows for direct visualization of necrotic or scarred tissue. By measuring the transmural extent of late enhancement, the probability of mechanical improvement can precisely be given. Imaging of microvascular obstruction by first-pass perfusion or late enhancement gives additional information on viability and patient prognosis. Metabolic imaging techniques, such as 31 P-MR spectroscopy and 23 Na-MR imaging, provide further insights into the mechanisms of myocardial infarction and viability. In conclusion, cardiac MRI offers several clinically usable approaches for the assessment of myocardial viability and will probably become the method of choice in the near future. (orig.)

  15. Stress myocardial scintigraphy in coronary artery disease

    International Nuclear Information System (INIS)

    Hata, Noritake; Koumi, Shin-ichi; Yasutake, Masahiro; Imaizumi, Takahiro; Saito, Tsutomu; Kishida, Hiroshi; Hayakawa, Hirokazu

    1991-01-01

    To evaluate the clinical significance of asymptomatic ischemic heart disease, exercise electrocardiography and stress myocardial scintigraphy were performed. These were correlated with symptoms during exercise tests and histories of myocardial infarction (MI). The study subjects consisted of 70 patients with coronary artery disease, including 34 with MI, and 36 without MI but with angina pectoris. Stress tests were performed using bicycle ergometer under electrocardiographic monitoring throughout the test. Transient myocardial ischemia was confirmed by perfusion defects on thallium myocardial imaging demonstrated immediately after exercise, but not 3 hours after the stress test. Asymptomatic ST depression was observed in 18 of 34 patients with MI (53%) and in 21 of the 36 patients with angina (58%); however, transient myocardial perfusion defects were confimred in 61% of the patients with MI (11 of 18 patients), but in only 33% of those with angina (7 of 21 patients). The difference was statistically significant (p<0.05). It was suggested that there are some differences in the clinical significance of asymptomatic ST depression between the patients with MI and those without MI but with angina pectoris. (author)

  16. Meta-Analysis of Stress Myocardial Perfusion Imaging

    Science.gov (United States)

    2017-06-06

    Coronary Disease; Echocardiography; Fractional Flow Reserve, Myocardial; Hemodynamics; Humans; Magnetic Resonance Imaging; Myocardial Perfusion Imaging; Perfusion; Predictive Value of Tests; Single Photon Emission Computed Tomography; Positron Emission Tomography; Multidetector Computed Tomography; Echocardiography, Stress; Coronary Angiography

  17. Association of blood transfusion with increased mortality in myocardial infarction

    DEFF Research Database (Denmark)

    Chatterjee, Saurav; Wetterslev, Jørn; Sharma, Abhishek

    2013-01-01

    The benefit of blood transfusion in patients with myocardial infarction is controversial, and a possibility of harm exists.......The benefit of blood transfusion in patients with myocardial infarction is controversial, and a possibility of harm exists....

  18. Aircraft noise, air pollution, and mortality from myocardial infarction.

    NARCIS (Netherlands)

    Huss, A.; Spoerri, A.; Egger, M.; Roosli, M.

    2010-01-01

    OBJECTIVE: Myocardial infarction has been associated with both transportation noise and air pollution. We examined residential exposure to aircraft noise and mortality from myocardial infarction, taking air pollution into account. METHODS: We analyzed the Swiss National Cohort, which includes

  19. Association between intraoperative hypotension and myocardial injury after vascular surgery

    NARCIS (Netherlands)

    van Waes, JAR; Van Klei, Wilton A.; Wijeysundera, Duminda N.; Van Wolfswinkel, Leo; Lindsay, Thomas F.; Beattie, W. Scott

    2016-01-01

    Background: Postoperative myocardial injury occurs frequently after noncardiac surgery and is strongly associated with mortality. Intraoperative hypotension (IOH) is hypothesized to be a possible cause. The aim of this study was to determine the association between IOH and postoperative myocardial

  20. Assmentment of myocardial perfusion by magnetic resonance imaging: on the way to clinical application

    International Nuclear Information System (INIS)

    Fischer, S.E.; Lorenz, C.H.

    1997-01-01

    Magnetic resonance imaging detects the flow of contrast - enhanced blood and even allows the quantitative assessment of myocardial perfusion. The clinical application of this method is being held back by the difficulties in image evaluation and the limitation of standard techniques to the acquisition of a single slice per heart beat cycle. Recent developments in scanner hardware as well as in image acquisition techniques open up the possibility of assessing myocardial perfusion over the entire heart with a spatial resolution in the range of 2 mm. As an example of such a new scanning strategy, a segmented gradient-echo recalled echo planar imaging sequence with preceding saturation is discussed and results in a patient with an infarction are presented. The clinical use of perfusion assessment covering the entire heart for the diagnosis of coronary artery disease is enhanced by the flexibility of magnetic resonance imaging for the assessment of functional cardiac parameters. (orig.) [de