Yoshiaki, A; Zhang, Y C
2002-01-01
Embedded nano-Pd particles of 5 nm in size instantly abundant D-atoms more than 250% in the atomic ratio against Pd-atoms at room temperature when they are kept in D sub 2 gas pressurized to less than 10 atm. In such ultrahigh densities, 2-4 D-atoms can be coagulated inside each octahedral space of Pd lattice (pycnodeuterium-lump). When a stimulation energy such as latticequake causing by ultrasonic wave was supplied to those highly deuterated Pd particles, intense deuterium nuclear fusion (''solid fusion'') was generated there and both excess heat and sup 4 He gas were abundantly produced. Naturally, these facts can not be realized at all in bulk Pd. The results show that the nuclear fusion occurs without any hazardous rays in pycnodeuterium-lumps coagulated locally inside the each cell of the host metal lattice. These unit cells correspond to minimum unit of the solid fusion reactor as a ''Lattice Reactor''. (author)
Lumped Mass Modeling for Local-Mode-Suppressed Element Connectivity
DEFF Research Database (Denmark)
Joung, Young Soo; Yoon, Gil Ho; Kim, Yoon Young
2005-01-01
connectivity parameterization (ECP) is employed. On the way to the ultimate crashworthy structure optimization, we are now developing a local mode-free topology optimization formulation that can be implemented in the ECP method. In fact, the local mode-freeing strategy developed here can be also used directly...... experiencing large structural changes, appears to be still poor. In ECP, the nodes of the domain-discretizing elements are connected by zero-length one-dimensional elastic links having varying stiffness. For computational efficiency, every elastic link is now assumed to have two lumped masses at its ends....... Choosing appropriate penalization functions for lumped mass and link stiffness is important for local mode-free results. However, unless the objective and constraint functions are carefully selected, it is difficult to obtain clear black-and-white results. It is shown that the present formulation is also...
Reduction of Turbidity of Water Using Locally Available Natural Coagulants
Asrafuzzaman, Md.; Fakhruddin, A. N. M.; Hossain, Md. Alamgir
2011-01-01
Turbidity imparts a great problem in water treatment. Moringa oleifera, Cicer arietinum, and Dolichos lablab were used as locally available natural coagulants in this study to reduce turbidity of synthetic water. The tests were carried out, using artificial turbid water with conventional jar test apparatus. Optimum mixing intensity and duration were determined. After dosing water-soluble extracts of Moringa oleifera, Cicer arietinum, and Dolichos lablab reduced turbidity to 5.9, 3.9, and 11.1 nephelometric turbidity unit (NTU), respectively, from 100 NTU and 5, 3.3, and 9.5, NTU, respectively, after dosing and filtration. Natural coagulants worked better with high, turbid, water compare to medium, or low, turbid, water. Highest turbidity reduction efficiency (95.89%) was found with Cicer arietinum. About 89 to 96% total coliform reduction were also found with natural coagulant treatment of turbid water. Using locally available natural coagulants, suitable, easier, and environment friendly options for water treatment were observed. PMID:23724307
Lump solutions to the Kadomtsev–Petviashvili equation
Energy Technology Data Exchange (ETDEWEB)
Ma, Wen-Xiu, E-mail: mawx@cas.usf.edu
2015-09-25
Through symbolic computation with Maple, a class of lump solutions, rationally localized in all directions in the space, to the (2 + 1)-dimensional Kadomtsev–Petviashvili (KP) equation is presented, making use of its Hirota bilinear form. The resulting lump solutions contain six free parameters, two of which are due to the translation invariance of the KP equation and the other four of which satisfy a non-zero determinant condition guaranteeing analyticity and rational localization of the solutions. Three contour plots with different determinant values are sequentially made to show that the corresponding lump solution tends to zero when the determinant approaches zero. Two particular lump solutions with specific values of the involved parameters are plotted, as illustrative examples. - Highlights: • Positive quadratic function solutions. • Solitons rationally-localized in all directions in the space. • Solving systems of nonlinear algebraic equations by symbolic computation with Maple.
Wang, Hao-Yuan; Zhao, Qing-Yu; Yuan, Yun-Fei
2008-07-01
Liver transplantation is widely accepted as an effective therapy of hepatoma. Perioperative dynamic observation of coagulation function is important for graft-receivers. This study was to explore perioperative changes of coagulation functions in the local advanced liver cancer patients who received liver transplantation. Clinical data of 31 local advanced liver cancer patients, underwent liver transplantation from Sep. 2003 to Jan. 2007, were analyzed. Platelet (PLT) counting, prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), fibrinogen (Fib) and international normalized ratio (INR) before operation, at anhepatic phase and the first week after operation were analyzed to evaluate congulation function. The coagulation functions of most patients were normal before operation. The six parameters varied significantly at anhepatic phase and on most days of the first week after operation when compared with the preoperative levels (Pfunctions of local advanced liver cancer patients shift from hypocoagulatory to hypercoagulatory or normal in perioperative period, therefore, prevention of bleeding should be focused on at anhepatic phase and on 1-2 days after operation while prevention of thrombosis should be focused on after the first week after operation. The degree of liver cirrhosis and Child-Pugh level could help to evaluate postoperative coagulation disorder.
Directory of Open Access Journals (Sweden)
R S Bhandari
2010-06-01
Full Text Available INTRODUCTION: Appendicular lump is a well known sequalae of acute appendicitis encountered in 2-6% of patients. Successful management of appendicular lump is controversial with different approaches. As many controversies are arising regarding management of appendicular lump. The aim of this study was to find out the outcome and evaluate possible need of changing our management strategy of appendicular lump. METHODS: A retrospective analysis of the patients managed with appendicular lump were done. All the patients admitted with diagnosis of appendicular lump and managed between, over two and half years, were included in the study. All age groups and both sex were included. Any patients whose diagnosis was changed after initial diagnosis of appendicular lump were excluded from the study. RESULTS: Total 75 patients had appendicular lump suggesting 10% incidence. Age varied between 11-83 years with nearly equal incidence in both sexes. Majority had onset of symptoms between 2 to 14 days with an average of 4 days. Average stay was 3 to 4 days. During study period, 12 (16% came with recurrence and 13 (17% cases came for elective appendectomy. CONCLUSIONS: Based on our finding, it is not sufficient to change our classical management strategy of appendicular lump and suggests a need for long term prospective study in this very common clinical condition. KEYWORDS: appendicular lump, conservative management.
Energy Technology Data Exchange (ETDEWEB)
Ibsen, Lars Bo; Liingaard, M.
2006-12-15
A lumped-parameter model represents the frequency dependent soil-structure interaction of a massless foundation placed on or embedded into an unbounded soil domain. In this technical report the steps of establishing a lumped-parameter model are presented. Following sections are included in this report: Static and dynamic formulation, Simple lumped-parameter models and Advanced lumped-parameter models. (au)
Bhandari, R S; Thakur, D K; Lakhey, P J; Singh, K P
2010-01-01
Appendicular lump is a well known sequalae of acute appendicitis encountered in 2-6% of patients. Successful management of appendicular lump is controversial with different approaches. As many controversies are arising regarding management of appendicular lump. The aim of this study was to find out the outcome and evaluate possible need of changing our management strategy of appendicular lump. A retrospective analysis of the patients managed with appendicular lump were done. All the patients admitted with diagnosis of appendicular lump and managed between, over two and half years, were included in the study. All age groups and both sex were included. Any patients whose diagnosis was changed after initial diagnosis of appendicular lump were excluded from the study. Total 75 patients had appendicular lump suggesting 10% incidence. Age varied between 11-83 years with nearly equal incidence in both sexes. Majority had onset of symptoms between 2 to 14 days with an average of 4 days. Average stay was 3 to 4 days. During study period, 12 (16%) came with recurrence and 13 (17%) cases came for elective appendectomy. Based on our finding, it is not sufficient to change our classical management strategy of appendicular lump and suggests a need for long term prospective study in this very common clinical condition.
The interplay between platelets and coagulation
Weeterings, C.
2009-01-01
Platelet activation and blood coagulation are two processes often studied separately, but which cannot be seen independently from each other. Platelets play a pivotal role in coagulation, not only by providing negatively charged phospholipids, but also in localizing the coagulation process from a
Causes of breast lumps (image)
... breast lumps are benign (non-cancerous), as in fibroadenoma, a condition that mostly affects women under age ... with the menstrual cycle, whereas a lump from fibroadenoma does not. While most breast lumps are benign, ...
Lump solutions with interaction phenomena in the (2+1)-dimensional Ito equation
Zou, Li; Yu, Zong-Bing; Tian, Shou-Fu; Feng, Lian-Li; Li, Jin
2018-03-01
In this paper, we consider the (2+1)-dimensional Ito equation, which was introduced by Ito. By considering the Hirota’s bilinear method, and using the positive quadratic function, we obtain some lump solutions of the Ito equation. In order to ensure rational localization and analyticity of these lump solutions, some sufficient and necessary conditions are provided on the parameters that appeared in the solutions. Furthermore, the interaction solutions between lump solutions and the stripe solitons are discussed by combining positive quadratic function with exponential function. Finally, the dynamic properties of these solutions are shown via the way of graphical analysis by selecting appropriate values of the parameters.
PEMBELAJARAN SENI TARI KUDA LUMPING DI DESA DUKUHWALUH KECAMATAN KEMBARAN KAB. BANYUMAS
Directory of Open Access Journals (Sweden)
Daryanto Daryanto
2011-03-01
Full Text Available The goals this research were to determine: 1. What are the requirements given to prospective players of Kuda Lumping; 2. What material provided and what methods are used in training Kuda Lumping; 3. What is the cost required to conduct training of Kuda Lumping, and from which source. 4. How long does it take to produce players who are ready to perform Kuda Lumping showcased in front of an audience. From the research result shows that: 1. Requirements given to players of Kuda Lumping (Ebeg, are namely: (1 has Kuda Lumping, (2 can dance in group / compact dance, (3 perform the ritual bathing and diving in rivers and (4 conduct ”Ngasrep” or fasting for 3 (three days without stopping. 2. The practice material was first given to prospective players Kuda Lumping is dance. In practing the dance material, the new dancers were directly guided by the seniors. The method used is by giving examples of dancing by the senior players to prospective players. When giving examples accompanied by gamelan / music, while dancer candidates of Kuda Lumping followed. 3. Fee required for training activities at least IDR 400,000,- (four hundred thousand rupiah. This cost does not include the cost to buy a kuda lumping. Sources of cost comes from the self-help group members of kuda lumping, like dalang ( director of the dance and local people. It means the training and activities of Kuda Lumping, did not receive funding / donations from the government, both the village and district governments. The cost for training activities was used to rent the gamelan, to purchase clothing / costume players, “sesaji”, consumption and honorariums. 4. To train / produce, it take a player at least 3.5 (three and a half months and a maximum of 7 (seven months. This calculation is based on the starting time of dance exercise, until doing the bath in the river as the last stage. Key Wordsi: Kuda lumping, learning ,ngasrep, ritual of bathe, ritual offerings, wayang,
Characterization of an air jet haptic lump display.
Bianchi, Matteo; Gwilliam, James C; Degirmenci, Alperen; Okamura, Allison M
2011-01-01
During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.
An Integrated Lumped Parameter-CFD approach for off-design ejector performance evaluation
International Nuclear Information System (INIS)
Besagni, Giorgio; Mereu, Riccardo; Chiesa, Paolo; Inzoli, Fabio
2015-01-01
Highlights: • We validate a CFD approach for a convergent nozzle ejector using global and local measurement. • We evaluate seven RANS turbulence models for convergent nozzle ejector. • We introduce a lumped parameter model for on-design and off-design ejector performance evaluation. • We analyze the relationship between local flow behavior and lumped parameters of the model. • We discuss how to improve predicting capabilities of the model by variable parameters calibrated on CFD simulations. - Abstract: This paper presents an Integrated Lumped Parameter Model-Computational Fluid-Dynamics approach for off-design ejector performance evaluation. The purpose of this approach is to evaluate the entrainment ratio, for a fixed geometry, in both on-design and off-design operating conditions. The proposed model is based on a Lumped Parameter Model (LPM) with variable ejector component efficiencies provided by CFD simulations. The CFD results are used for developing maps for ejector component efficiencies in a broad range of operating conditions. The ejector component efficiency maps couple the CFD and the LPM techniques for building an Integrated LPM-CFD approach. The proposed approach is demonstrated for a convergent nozzle ejector and the paper is structured in four parts. At first, the CFD approach is validated by global and local data and seven Reynolds Averaged Navier Stokes (RANS) turbulence models are compared: the k–ω SST showed good performance and was selected for the rest of the analysis. At second, a Lumped Parameter Model (LPM) for subsonic ejector is developed and the ejector component efficiencies have been defined. At third, the CFD approach is used to investigate the flow field, to analyze its influence on ejector component efficiencies and to propose efficiency correlations and maps linking ejector component efficiencies and local flow quantities. In the last part, the efficiency maps are embedded into the lumped parameter model, thus creating
Directory of Open Access Journals (Sweden)
Meric Ataman
2017-07-01
Full Text Available In the post-genomic era, Genome-scale metabolic networks (GEMs have emerged as invaluable tools to understand metabolic capabilities of organisms. Different parts of these metabolic networks are defined as subsystems/pathways, which are sets of functional roles to implement a specific biological process or structural complex, such as glycolysis and TCA cycle. Subsystem/pathway definition is also employed to delineate the biosynthetic routes that produce biomass building blocks. In databases, such as MetaCyc and SEED, these representations are composed of linear routes from precursors to target biomass building blocks. However, this approach cannot capture the nested, complex nature of GEMs. Here we implemented an algorithm, lumpGEM, which generates biosynthetic subnetworks composed of reactions that can synthesize a target metabolite from a set of defined core precursor metabolites. lumpGEM captures balanced subnetworks, which account for the fate of all metabolites along the synthesis routes, thus encapsulating reactions from various subsystems/pathways to balance these metabolites in the metabolic network. Moreover, lumpGEM collapses these subnetworks into elementally balanced lumped reactions that specify the cost of all precursor metabolites and cofactors. It also generates alternative subnetworks and lumped reactions for the same metabolite, accounting for the flexibility of organisms. lumpGEM is applicable to any GEM and any target metabolite defined in the network. Lumped reactions generated by lumpGEM can be also used to generate properly balanced reduced core metabolic models.
International Nuclear Information System (INIS)
Luescher, M.; Pohlmeyer, K.
1977-09-01
Finite energy solutions of the field equations of the non-linear sigma-model are shown to decay asymptotically into massless lumps. By means of a linear eigenvalue problem connected with the field equations we then find an infinite set of dynamical conserved charges. They, however, do not provide sufficient information to decode the complicated scattering of lumps. (orig.) [de
Application of Moringa Oleifera Seed Powder For Iron (III Coagulation on Local Water Resources
Directory of Open Access Journals (Sweden)
Fadillah Utami Prasetyaningtyas
2013-07-01
Full Text Available This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter. A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives a possitives result to the river water sample using 100 mg coagulant mass and sedimentations time for 60 minutes, well water sample using 500 mg coagulant mass and sedimentations time for 60 minutes, tap water sample using 300 mg coagulant mass and sedimentations time for 90 minutes. The effective coagulant that increase the water quality on well water is 98,32% of moringa seed powder, on river water is 96,64% and for tap water is 25,62%.
Simulation of hydrogen deflagration experiment – Benchmark exercise with lumped-parameter codes
Energy Technology Data Exchange (ETDEWEB)
Kljenak, Ivo, E-mail: ivo.kljenak@ijs.si [Jožef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia); Kuznetsov, Mikhail, E-mail: mike.kuznetsov@kit.edu [Karlsruhe Institute of Technology, Kaiserstraße 12, 76131 Karlsruhe (Germany); Kostka, Pal, E-mail: kostka@nubiki.hu [NUBIKI Nuclear Safety Research Institute, Konkoly-Thege Miklós út 29-33, 1121 Budapest (Hungary); Kubišova, Lubica, E-mail: lubica.kubisova@ujd.gov.sk [Nuclear Regulatory Authority of the Slovak Republic, Bajkalská 27, 82007 Bratislava (Slovakia); Maltsev, Mikhail, E-mail: maltsev_MB@aep.ru [JSC Atomenergoproekt, 1, st. Podolskykh Kursantov, Moscow (Russian Federation); Manzini, Giovanni, E-mail: giovanni.manzini@rse-web.it [Ricerca sul Sistema Energetico, Via Rubattino 54, 20134 Milano (Italy); Povilaitis, Mantas, E-mail: mantas.p@mail.lei.lt [Lithuania Energy Institute, Breslaujos g.3, 44403 Kaunas (Lithuania)
2015-03-15
Highlights: • Blind and open simulations of hydrogen combustion experiment in large-scale containment-like facility with different lumped-parameter codes. • Simulation of axial as well as radial flame propagation. • Confirmation of adequacy of lumped-parameter codes for safety analyses of actual nuclear power plants. - Abstract: An experiment on hydrogen deflagration (Upward Flame Propagation Experiment – UFPE) was proposed by the Jozef Stefan Institute (Slovenia) and performed in the HYKA A2 facility at the Karlsruhe Institute of Technology (Germany). The experimental results were used to organize a benchmark exercise for lumped-parameter codes. Six organizations (JSI, AEP, LEI, NUBIKI, RSE and UJD SR) participated in the benchmark exercise, using altogether four different computer codes: ANGAR, ASTEC, COCOSYS and ECART. Both blind and open simulations were performed. In general, all the codes provided satisfactory results of the pressure increase, whereas the results of the temperature show a wider dispersal. Concerning the flame axial and radial velocities, the results may be considered satisfactory, given the inherent simplification of the lumped-parameter description compared to the local instantaneous description.
Simulation of hydrogen deflagration experiment – Benchmark exercise with lumped-parameter codes
International Nuclear Information System (INIS)
Kljenak, Ivo; Kuznetsov, Mikhail; Kostka, Pal; Kubišova, Lubica; Maltsev, Mikhail; Manzini, Giovanni; Povilaitis, Mantas
2015-01-01
Highlights: • Blind and open simulations of hydrogen combustion experiment in large-scale containment-like facility with different lumped-parameter codes. • Simulation of axial as well as radial flame propagation. • Confirmation of adequacy of lumped-parameter codes for safety analyses of actual nuclear power plants. - Abstract: An experiment on hydrogen deflagration (Upward Flame Propagation Experiment – UFPE) was proposed by the Jozef Stefan Institute (Slovenia) and performed in the HYKA A2 facility at the Karlsruhe Institute of Technology (Germany). The experimental results were used to organize a benchmark exercise for lumped-parameter codes. Six organizations (JSI, AEP, LEI, NUBIKI, RSE and UJD SR) participated in the benchmark exercise, using altogether four different computer codes: ANGAR, ASTEC, COCOSYS and ECART. Both blind and open simulations were performed. In general, all the codes provided satisfactory results of the pressure increase, whereas the results of the temperature show a wider dispersal. Concerning the flame axial and radial velocities, the results may be considered satisfactory, given the inherent simplification of the lumped-parameter description compared to the local instantaneous description
LENUS (Irish Health Repository)
Cooley, S
2011-06-01
A review of the efficacy and outcome of fifteen fetoscopic laser ablations under local anaesthesia for twin to twin transfusion syndrome (TTTS) in the National Maternity Hospital Dublin was undertaken. The mean gestation at laser was 19.7 weeks (range 16-25 weeks) with a mean gestation at delivery of 29.1 weeks (range 20-35 weeks). The overall liveborn birth rate was 79% (22 infants) and one pregnancy was still ongoing. There were four neonatal deaths secondary to complications of prematurity. The surviving eighteen infants (64%) undergo regular paediatric review. The procedure was performed successfully in all cases with local anaesthesia. In no case was there maternal discomfort that warranted the procedure to be abandoned and good visual access of the vascular anastamoses was obtained in all cases. Local anaesthesia therefore offers a safe effective anaesthetic option for fetoscopic laser coagulation in monochorionic pregnancies complicated by TTTS.
Application of Moringa Oleifera Seed Powder for Iron (III) Coagulation on Local Water Resources
Prasetyaningtyas, Fadillah Utami; Rumhayati, Barlah; Masruri, Masruri
2013-01-01
This research aims to know the effect of the use of powder moringa seed to coagulant mass and coagulation process, and its effectiveness to increase the quality of pure water. This research uses factorial research design and statistic test MANOVA. To analyse water quality, the researcher uses Fe parameter. A graphic of coagulant mass and time for each parameter is used to analyse the data. Based on the research result, the uses of moringa seed as coagulant in each 300 mL mineral water gives ...
Cytomorphological study of palpable breast lumps
Directory of Open Access Journals (Sweden)
PK Choudhary
2015-09-01
Full Text Available Background: Breast lump is a very common clinical presentation for which fine needle aspiration cytology is often sought for. Because of it’s significant diagnositic value, FNAC has become a routine tool in the evaluation of the nature of the lesion. The objective of this study was to determine the cytomorphological patterns of breast lump in eastern part of Nepal among individuals attending Nobel Medical College. Materials and Methods: This was a retrospective descriptive study done in department of pathology from December 2012 to June 2015. All individuals presenting with breast lumps was included in this study. FNAC was done as per standard procedure and categorized as per United Kingdom National Health Survey Breast Screening Programme (UK-NHS-BSP categories and further also categorized in to neoplastic and non-neolastic categories. Results: We studied 771 cases of breast lumps. Occurrence of breast lump was more common in female (97.4%. Neoplastic lesions accounted for 84.1% of cases out of which benign comprised of 94.6% and malignant comprised of 5.6%. Common benign lesions observed were that of fibroadenona (264 and fibrocystic changes (204. Ductal carcinoma was the most common malignant lesions. All malignant lesions were observed in older age and female sex population.Conclusion: Most of the cases of breast lumps are benign in nature and very few accounted for malignant cases. There is predominance of benign lesions in young age and increased malignancy in older age and female population.
Rational Solutions and Lump Solutions of the Potential YTSF Equation
Sun, Hong-Qian; Chen, Ai-Hua
2017-07-01
By using of the bilinear form, rational solutions and lump solutions of the potential Yu-Toda-Sasa-Fukuyama (YTSF) equation are derived. Dynamics of the fundamental lump solution, n1-order lump solutions, and N-lump solutions are studied for some special cases. We also find some interaction behaviours of solitary waves and one lump of rational solutions.
7 CFR 1726.205 - Multiparty lump sum quotations.
2010-01-01
... 7 Agriculture 11 2010-01-01 2010-01-01 false Multiparty lump sum quotations. 1726.205 Section 1726....205 Multiparty lump sum quotations. The borrower or its engineer must contact a sufficient number of... basis of written lump sum quotations, the borrower will select the supplier or contractor based on the...
Energy Technology Data Exchange (ETDEWEB)
Tan, Long, E-mail: mse.longtan@gmail.com [State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Zhang, Jianxun; Zhuang, Dong [State Key Laboratory for Mechanical Behavior of Materials, School of Materials Science and Engineering, Xi’an Jiaotong University, Xi’an 710049 (China); Liu, Chuan [Provincial Key Lab of Advanced Welding Technology, Jiangsu University of Science and Technology, Zhenjiang 212003 (China)
2014-07-01
Highlights: • The internal residual stress of the thick-walled pipe is measured by using the local removal blind hole method. • Two lumped-pass models are developed to reduce computational cost. • The effect of lumped passes on the welding residual stress is discussed. • Reasonable lumped-pass model can guarantee the accuracy and improve the computational efficiency. - Abstract: The purpose of this study is to investigate the effect of the lumped passes simulation on the distribution of residual stresses before and after heat treatment in a thick-walled nuclear power rotor pipe with a 89-pass narrow gap welding process. The local removal blind hole method was used to measure internal residual stress of the thick-walled pipe after post weld heat treatment (PWHT). Based on the ANSYS software, a two-dimensional axisymmetric finite element model is employed. Two lumped-pass models of M-5th model (five weld beads as one lumped pass) and M-10th model (ten weld beads as one lumped pass) were developed to reduce computational cost. Based on the results in this study, the distributions of residual stresses of a thick-walled welded pipe before and after PWHT are developed. Meanwhile, the distribution of the through-wall axial residual stress along the weld center line is demonstrated to be a self-equilibrating type. In addition, the investigation results show that reasonable and reliable lumped-pass model can not only guarantee the accuracy of the simulated results, but also improve the computational efficiency in the thermo-elastic–plastic FE analysis procedure. Therefore, from the viewpoint of engineering application the developed lumped-pass computational procedure is a promising and useful method to predict residual stress of large and complex welded structures.
International Nuclear Information System (INIS)
Tan, Long; Zhang, Jianxun; Zhuang, Dong; Liu, Chuan
2014-01-01
Highlights: • The internal residual stress of the thick-walled pipe is measured by using the local removal blind hole method. • Two lumped-pass models are developed to reduce computational cost. • The effect of lumped passes on the welding residual stress is discussed. • Reasonable lumped-pass model can guarantee the accuracy and improve the computational efficiency. - Abstract: The purpose of this study is to investigate the effect of the lumped passes simulation on the distribution of residual stresses before and after heat treatment in a thick-walled nuclear power rotor pipe with a 89-pass narrow gap welding process. The local removal blind hole method was used to measure internal residual stress of the thick-walled pipe after post weld heat treatment (PWHT). Based on the ANSYS software, a two-dimensional axisymmetric finite element model is employed. Two lumped-pass models of M-5th model (five weld beads as one lumped pass) and M-10th model (ten weld beads as one lumped pass) were developed to reduce computational cost. Based on the results in this study, the distributions of residual stresses of a thick-walled welded pipe before and after PWHT are developed. Meanwhile, the distribution of the through-wall axial residual stress along the weld center line is demonstrated to be a self-equilibrating type. In addition, the investigation results show that reasonable and reliable lumped-pass model can not only guarantee the accuracy of the simulated results, but also improve the computational efficiency in the thermo-elastic–plastic FE analysis procedure. Therefore, from the viewpoint of engineering application the developed lumped-pass computational procedure is a promising and useful method to predict residual stress of large and complex welded structures
Single lump breast surface stress assessment study
Vairavan, R.; Ong, N. R.; Sauli, Z.; Kirtsaeng, S.; Sakuntasathien, S.; Paitong, P.; Alcain, J. B.; Lai, S. L.; Retnasamy, V.
2017-09-01
Breast cancer is one of the commonest cancers diagnosed among women around the world. Simulation approach has been utilized to study, characterize and improvise detection methods for breast cancer. However, minimal simulation work has been done to evaluate the surface stress of the breast with lumps. Thus, in this work, simulation analysis was utilized to evaluate and assess the breast surface stress due to the presence of a lump within the internal structure of the breast. The simulation was conducted using the Elmer software. Simulation results have confirmed that the presence of a lump within the breast causes stress on the skin surface of the breast.
28 CFR 523.16 - Lump sum awards.
2010-07-01
... satisfactory performance of an unusually hazardous assignment; (c) An act which protects the lives of staff or... TRANSFER COMPUTATION OF SENTENCE Extra Good Time § 523.16 Lump sum awards. Any staff member may recommend... award is calculated. No seniority is accrued for such awards. Staff may recommend lump sum awards of...
Representing Lumped Markov Chains by Minimal Polynomials over Field GF(q)
Zakharov, V. M.; Shalagin, S. V.; Eminov, B. F.
2018-05-01
A method has been proposed to represent lumped Markov chains by minimal polynomials over a finite field. The accuracy of representing lumped stochastic matrices, the law of lumped Markov chains depends linearly on the minimum degree of polynomials over field GF(q). The method allows constructing the realizations of lumped Markov chains on linear shift registers with a pre-defined “linear complexity”.
Analysis and design of lumped element Marchand baluns
DEFF Research Database (Denmark)
Johansen, Tom Keinicke; Krozer, Viktor
2008-01-01
In this paper a novel design procedure for lumped element Marchand baluns is proposed. An analysis is performed on the balun structure in order to determine the conditions for ideal balun performance in terms of the lumped element values. The analysis is verified by two broadband designs centered...... around 22.75 GHz and differing only in terms of their impedance transformation ratio. EM simulation results on our proposed lumped element Marchand balun structure predicts an insertion loss of 4 dB and return loss of 40 dB at the design frequency of 22.75 GHz. The amplitude and phase imbalance...
Pembelajaran Seni Tari Kuda Lumping Di Desa Dukuhwaluh Kecamatan Kembaran Kab. Banyumas
Daryanto, Daryanto
2011-01-01
The goals this research were to determine: 1). What are the requirements given to prospective players of Kuda Lumping; 2). What material provided and what methods are used in training Kuda Lumping; 3). What is the cost required to conduct training of Kuda Lumping, and from which source. 4). How long does it take to produce players who are ready to perform Kuda Lumping showcased in front of an audience. From the research result shows that: 1. Requirements given to players of Kuda Lumping...
PEMBELAJARAN SENI TARI KUDA LUMPING DI DESA DUKUHWALUH KECAMATAN KEMBARAN KAB. BANYUMAS
Daryanto Daryanto
2011-01-01
The goals this research were to determine: 1). What are the requirements given to prospective players of Kuda Lumping; 2). What material provided and what methods are used in training Kuda Lumping; 3). What is the cost required to conduct training of Kuda Lumping, and from which source. 4). How long does it take to produce players who are ready to perform Kuda Lumping showcased in front of an audience. From the research result shows that: 1. Requirements given to players of Kuda Lumping...
Decay of Kadomtsev-Petviashvili lumps in dissipative media
Clarke, S.; Gorshkov, K.; Grimshaw, R.; Stepanyants, Y.
2018-03-01
The decay of Kadomtsev-Petviashvili lumps is considered for a few typical dissipations-Rayleigh dissipation, Reynolds dissipation, Landau damping, Chezy bottom friction, viscous dissipation in the laminar boundary layer, and radiative losses caused by large-scale dispersion. It is shown that the straight-line motion of lumps is unstable under the influence of dissipation. The lump trajectories are calculated for two most typical models of dissipation-the Rayleigh and Reynolds dissipations. A comparison of analytical results obtained within the framework of asymptotic theory with the direct numerical calculations of the Kadomtsev-Petviashvili equation is presented. Good agreement between the theoretical and numerical results is obtained.
Kubesa, Petr; Horák, Jiří; Branc, Michal; Krpec, Kamil; Hopan, František; Koloničný, Jan; Ochodek, Tadeáš; Drastichová, Vendula; Martiník, Lubomír; Malcho, Milan
2014-08-01
The article deals with the combustion process for lump wood in low-power fireplaces (units to dozens of kW). Such a combustion process is cyclical in its nature, and what combustion facility users are most interested in is the frequency, at which fuel needs to be stoked to the fireplace. The paper defines the basic terms such as burnout curve and burning rate curve, which are closely related to the stocking frequency. The fuel burning rate is directly dependent on the immediate thermal power of the fireplace. This is also related to the temperature achieved in the fireplace, magnitude of flue gas losses and the ability to generate conditions favouring the full burnout of the fuel's combustible component, which, at once ensures the minimum production of combustible pollutants. Another part of the paper describes experiments conducted in traditional fireplaces with a grate, at which well-dried lump wood was combusted.
Directory of Open Access Journals (Sweden)
Šćiban Marina B.
2005-01-01
Full Text Available The ability of seeds of plants: Phaseolus vulgaris, Robinia pseudoacacia Ceratonia siliqua and Amorpha fruticosa, to act as natural coagulants was tested using synthetic turbid water. This water was prepared by adding kaolin into tap water, just before the test. Active components were extracted from ground seeds with distilled water. The coagulation ability of this extract was assessed by the use of standard jar test measurements in water with various initial turbidity. Investigation of these natural coagulants was confirmed their positive coagulation activity. Of all plants that have been examined, the seed extract from Ceratonia siliqua appeared to be one of the most effective coagulants for water treatment. A dose of 20 mg/l of this coagulant resulted in 100% coagulation activity for clarification of water with 17.5 NTU initial turbidity.
Comments on lump solutions in SFT
International Nuclear Information System (INIS)
Bonora, Loriano; Tolla, Driba D.
2016-01-01
We analyze a recently proposed scheme to construct analytic lump solutions in open SFT. We argue that in order for the scheme to be operative and to guarantee background independence it must be implemented in the same 2D conformal field theory in which SFT is formulated. We outline and discuss two different possible approaches. Next we reconsider an older proposal for analytic lump solutions and implement a few improvements. In the course of the analysis we formulate a distinction between regular and singular gauge transformations and advocate the necessity of defining a topology in the space of string fields. (orig.)
Comments on lump solutions in SFT
Energy Technology Data Exchange (ETDEWEB)
Bonora, Loriano; Tolla, Driba D. [International School for Advanced Studies (SISSA), Trieste (Italy); INFN, Sezione di Trieste, Trieste (Italy)
2016-04-15
We analyze a recently proposed scheme to construct analytic lump solutions in open SFT. We argue that in order for the scheme to be operative and to guarantee background independence it must be implemented in the same 2D conformal field theory in which SFT is formulated. We outline and discuss two different possible approaches. Next we reconsider an older proposal for analytic lump solutions and implement a few improvements. In the course of the analysis we formulate a distinction between regular and singular gauge transformations and advocate the necessity of defining a topology in the space of string fields. (orig.)
LENUS (Irish Health Repository)
Porter, J M
2012-02-03
Amide local anaesthetics impair coagulation by inhibition of platelet function and enhanced fibrinolysis. The potential therefore exists that the presence of amide local anaesthetics in the epidural space could contribute to the therapeutic failure of an epidural autologous blood patch. Ropivacaine is an aminoamide local anaesthetic increasingly used for epidural analgesia and anaesthesia, particularly in obstetric practice. This study was undertaken to investigate whether concentrations of ropivacaine in blood, which could occur clinically in the epidural space, alter coagulation or fibrinolysis. Thromboelastography was used to assess clotting and fibrinolysis of blood to which ropivacaine had been added. Although modest alterations in maximum amplitude, coagulation time and alpha angle were observed, the effect of ropivacaine on clotting and fibrinolysis was not clinically significant. We conclude that it is unlikely that the presence of ropivacaine in the epidural space would reduce the efficacy of an early or prophylactic epidural blood patch.
Application of Mass Lumped Higher Order Finite Elements
International Nuclear Information System (INIS)
J. Chen, H.R. Strauss, S.C. Jardin, W. Park, L.E. Sugiyama, G. Fu, J. Breslau
2005-01-01
There are many interesting phenomena in extended-MHD such as anisotropic transport, mhd, 2-fluid effects stellarator and hot particles. Any one of them challenges numerical analysts, and researchers are seeking for higher order methods, such as higher order finite difference, higher order finite elements and hp/spectral elements. It is true that these methods give more accurate solution than their linear counterparts. However, numerically they are prohibitively expensive. Here we give a successful solution of this conflict by applying mass lumped higher order finite elements. This type of elements not only keep second/third order accuracy but also scale closely to linear elements by doing mass lumping. This is especially true for second order lump elements. Full M3D and anisotropic transport models are studied
Overview of the coagulation system.
Palta, Sanjeev; Saroa, Richa; Palta, Anshu
2014-09-01
Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms 'coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.
Overview of the coagulation system
Directory of Open Access Journals (Sweden)
Sanjeev Palta
2014-01-01
Full Text Available Coagulation is a dynamic process and the understanding of the blood coagulation system has evolved over the recent years in anaesthetic practice. Although the traditional classification of the coagulation system into extrinsic and intrinsic pathway is still valid, the newer insights into coagulation provide more authentic description of the same. Normal coagulation pathway represents a balance between the pro coagulant pathway that is responsible for clot formation and the mechanisms that inhibit the same beyond the injury site. Imbalance of the coagulation system may occur in the perioperative period or during critical illness, which may be secondary to numerous factors leading to a tendency of either thrombosis or bleeding. A systematic search of literature on PubMed with MeSH terms ′coagulation system, haemostasis and anaesthesia revealed twenty eight related clinical trials and review articles in last 10 years. Since the balance of the coagulation system may tilt towards bleeding and thrombosis in many situations, it is mandatory for the clinicians to understand physiologic basis of haemostasis in order to diagnose and manage the abnormalities of the coagulation process and to interpret the diagnostic tests done for the same.
Rigorous theoretical derivation of lumped models to transmission line systems
International Nuclear Information System (INIS)
Zhao Jixiang
2012-01-01
By virtue of the negative electric parameter concept, i.e. negative lumped resistance, inductance, conductance and capacitance (N-RLGC), the lumped equivalent models of transmission line systems, including the circuit model, two-port π-network and T-network, are given. We start from the N-segment-ladder-like equivalent networks composed distributed parameters, and achieve the input impedance in the form of a continued fraction. Utilizing the continued fraction theory, the expressions of input impedance are obtained under three kinds of extreme cases, i.e. the load impedances are equal to zero, infinity and characteristic impedance, respectively. When the number of segment N is limited to infinity, they are transformed to lumped elements. Comparison between the distributed model and lumped model of transmission lines, the expression of tanh γd, which is the key term in the transmission line equations, are obtained by RLGC, furthermore, according to input admittance, admittance matrix and ABCD matrix of transmission lines, the lumped equivalent circuit models, π-networks and T-networks have been given. The models are verified in the frequency and time domain, respectively, showing that the models are accurate and efficient. (semiconductor integrated circuits)
Lumped-parameter Model of a Bucket Foundation
DEFF Research Database (Denmark)
Andersen, Lars; Ibsen, Lars Bo; Liingaard, Morten
2009-01-01
efficient model that can be applied in aero-elastic codes for fast evaluation of the dynamic structural response of wind turbines. The target solutions, utilised for calibration of the lumped-parameter models, are obtained by a coupled finite-element/boundaryelement scheme in the frequency domain......, and the quality of the models are tested in the time and frequency domains. It is found that precise results are achieved by lumped-parameter models with two to four internal degrees of freedom per displacement or rotation of the foundation. Further, coupling between the horizontal sliding and rocking cannot...
A Temperature Dependent Lumped-charge Model for Trench FS-IGBT
DEFF Research Database (Denmark)
Duan, Yaoqiang; Kang, Yong; Iannuzzo, Francesco
2018-01-01
Abstract: This paper proposes a temperature dependent lumped-charge model for FS-IGBT. Due to the evolution of the IGBT structure, the existing lumped-charge IGBT model established for NPT-IGBT is not suitable for the simulation of FS-IGBT. This paper extends the lumped-charge IGBT model including...... the field-stop (FS) structure and temperature characteristics. The temperature characteristics of the model are considered for both the bipolar part and unipolar part. In addition, a new PN junction model which can distinguish the collector structure is presented and validated by TCAD simulation. Finally...
Application of Biologically-Based Lumping To Investigate the ...
People are often exposed to complex mixtures of environmental chemicals such as gasoline, tobacco smoke, water contaminants, or food additives. However, investigators have often considered complex mixtures as one lumped entity. Valuable information can be obtained from these experiments, though this simplification provides little insight into the impact of a mixture's chemical composition on toxicologically-relevant metabolic interactions that may occur among its constituents. We developed an approach that applies chemical lumping methods to complex mixtures, in this case gasoline, based on biologically relevant parameters used in physiologically-based pharmacokinetic (PBPK) modeling. Inhalation exposures were performed with rats to evaluate performance of our PBPK model. There were 109 chemicals identified and quantified in the vapor in the chamber. The time-course kinetic profiles of 10 target chemicals were also determined from blood samples collected during and following the in vivo experiments. A general PBPK model was used to compare the experimental data to the simulated values of blood concentration for the 10 target chemicals with various numbers of lumps, iteratively increasing from 0 to 99. Large reductions in simulation error were gained by incorporating enzymatic chemical interactions, in comparison to simulating the individual chemicals separately. The error was further reduced by lumping the 99 non-target chemicals. Application of this biologic
Experimental realization of optical lumped nanocircuits at infrared wavelengths.
Sun, Yong; Edwards, Brian; Alù, Andrea; Engheta, Nader
2012-01-29
The integration of radiofrequency electronic methodologies on micro- as well as nanoscale platforms is crucial for information processing and data-storage technologies. In electronics, radiofrequency signals are controlled and manipulated by 'lumped' circuit elements, such as resistors, inductors and capacitors. In earlier work, we theoretically proposed that optical nanostructures, when properly designed and judiciously arranged, could behave as nanoscale lumped circuit elements--but at optical frequencies. Here, for the first time we experimentally demonstrate a two-dimensional optical nanocircuit at mid-infrared wavelengths. With the guidance of circuit theory, we design and fabricate arrays of Si3N4 nanorods with specific deep subwavelength cross-sections, quantitatively evaluate their equivalent impedance as lumped circuit elements in the mid-infrared regime, and by Fourier transform infrared spectroscopy show that these nanostructures can indeed function as two-dimensional optical lumped circuit elements. We further show that the connections among nanocircuit elements, in particular whether they are in series or in parallel combination, can be controlled by the polarization of impinging optical signals, realizing the notion of 'stereo-circuitry' in metatronics-metamaterials-inspired optical circuitry.
Local intravascular coagulation and fibrin deposition on intestinal ischemia-reperfusion in rats
Schoots, Ivo G.; Levi, Marcel; Roossink, E. H. Paulina; Bijlsma, Pieter B.; van Gulik, Thomas M.
2003-01-01
Background. This study investigates intravascular coagulation and thrombotic obstruction in the splanchnic vasculature after intestinal ischemia in relation to epithelial integrity and function. Methods. Intestinal ischemia was induced in rats by superior mesenteric artery occlusion for 20 or 40
The role of men in early detection of their spouses' breast lump(s ...
African Journals Online (AJOL)
We aim to determine whether men can be of help in the early detection of lumps in their spouses' breast. 230 questionnaires were administered to married men. The responses were accepted as “yes” or “no. 217 men (94.35%) responded. 195 (89.86%) were aware of breast cancer. 212 ( 97.7%) were either Christians or ...
Rutting resistance of asphalt mixture with cup lumps modified binder
Shaffie, E.; Hanif, W. M. M. Wan; Arshad, A. K.; Hashim, W.
2017-11-01
Rutting is the most common pavement distress in pavement structures which occurs mainly due to several factors such as increasing of traffic volume, climatic conditions and also due to construction design errors. This failure reduced the service life of the pavement, reduced driver safety and increase cost of maintenance. Polymer Modified Binder has been observed for a long time in improving asphalt pavement performance. Research shows that the use of polymer in bituminous mix not only improve the resistance to rutting but also increase the life span of the pavement. This research evaluates the physical properties and rutting performance of dense graded Superpave-designed HMA mix. Two different types of dense graded Superpave HMA mix were developed consists of unmodified binder mix (UMB) and cup lumps rubber (liquid form) modified binder mix (CLMB). Natural rubber polymer modified binder was prepared from addition of 8 percent of cup lumps into binder. Results showed that all the mixes passed the Superpave volumetric properties criteria which indicate that these mixtures were good with respect to durability and flexibility. Furthermore, rutting results from APA rutting test was determined to evaluate the performance of these mixtures. The rutting result of CLMB demonstrates better resistance to rutting than those prepared using UMB mix. Addition of cup lumps rubber in asphalt mixture was found to be significant, where the cup lumps rubber has certainly improves the binder properties and enhanced its rutting resistance due to greater elasticity offered by the cup lumps rubber particles. It shows that the use of cup lumps rubber can significantly reduce the rut depth of asphalt mixture by 41% compared to the minimum rut depth obtained for the UMB mix. Therefore, it can be concluded that the cup lumps rubber is suitable to be used as a modifier to modified binder in order to enhance the properties of the binder and thus improves the performance of asphalt mixes.
Nora SEGHAIRI; Leila MIMECHE; Adel BOUZID; Yassir AYACHI
2017-01-01
Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose,...
Application of lumped-parameter models
DEFF Research Database (Denmark)
Ibsen, Lars Bo; Liingaard, Morten
This technical report concerns the lumped-parameter models for a suction caisson with a ratio between skirt length and foundation diameter equal to 1/2, embedded into an viscoelastic soil. The models are presented for three different values of the shear modulus of the subsoil (section 1.1). Subse...
Blood coagulation factors as inflammatory mediators
Schoenmakers, Saskia H. H. F.; Reitsma, Pieter H.; Spek, C. Arnold
2005-01-01
After the first observations about blood coagulation by Hippocrates, it took until the early 1900s before the classic theory of blood coagulation was presented. As more and more other coagulation factors were discovered, the four-factor coagulation scheme became more complex, but better understood,
Lumped transmission line avalanche pulser
Booth, Rex
1995-01-01
A lumped linear avalanche transistor pulse generator utilizes stacked transistors in parallel within a stage and couples a plurality of said stages, in series with increasing zener diode limited voltages per stage and decreasing balanced capacitance load per stage to yield a high voltage, high and constant current, very short pulse.
Directory of Open Access Journals (Sweden)
S P Susheela
2015-05-01
Full Text Available Hepatocellular carcinoma (HCC is one of the most common malignancies and is known to most often present with symptomatology pertaining to local hepatic disease. Although HCC is known to metastasize to lungs, abdominal lymph nodes, adrenal glands and the vertebral column, it is rather rare to come across patients with skull metastasis. The manifestation of a solitary frontal bone metastasis leading to a painless lump over the forehead as the initial presenting feature of HCC is highly unusual. This case report pertains to a 40-year-old male patient who had initially observed a painless lump over his forehead that was gradually increasing in size over a span of 3 months. He sought medical attention when, after several months, the "painless lump" suddenly became painful. Investigations revealed the involvement of both the outer and the inner table of the frontal bone, and a biopsy revealed the histopathology to be that of HCC. On further investigation, he was found to have systemic disseminated disease involving both the left and right lungs and vertebrae and treatment was initiated with sorafenib. Despite an initial partial response, the patient subsequently succumbed to hepatic failure. This case report illustrates the fact that HCC can silently progress, and even lead to dissemination and distant metastases before becoming clinically evident.
COAGULATION ACTIVITY IN LIVER DISEASE
Directory of Open Access Journals (Sweden)
Dr. Sheikh Sajjadieh Mohammad Reza
2009-07-01
Full Text Available Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation markers were assayed in 60 participants: 20 patients with chronic hepatitis, 20 patients with cirrhosis, and 20 healthy individuals (control. Plasma levels of anti-thrombin III were determined by a chromogenic substrate method, and plasma concentrations of fibrinogen were analyzed by the Rutberg method. Commercially available assays were used for laboratory coagulation tests. The levels of coagualation activity markers in patients with chronic liver disease were significantly different in comparison to those in healthy participants. These results indicate the utility of measuring markers for coagulation activity in determining which cirrhosis patients are more susceptible to disseminated intravascular coagulation.
Energy Technology Data Exchange (ETDEWEB)
Wei, Yanxin; Lu, Jinpeng; Dong, Xiongzi; Yao, Chengli [Hefei Normal University, Hefei (China); Hao, Jianwen [Anhui Vocational and Technical College, Hefei (China)
2017-10-15
The process of coagulation-flocculation is increasingly applied in wastewater treatment. And the polymerized inorganic coagulants are widely used among these coagulation-flocculation processes. However, conventional coagulants using sulfates or chlorides as counter anion may give rise to corrosion. The purpose of this study was to synthesize PFC coagulants in which acetate is used as counter anion. The influences on the preparation of PFC were optimized. The synthesis was done at the optimum conditions, such as temperature of 60 .deg. C, the Fe/CH{sub 3}COOH molar ratio of 1 : 4.0 and reaction time of 6 h, respectively. The prepared PFC coagulants were characterized by Fourier transform infrared (FTIR) spectrophotometry and scanning electron microscopy (SEM). PFC was found to mainly form complexation polymeric species and present more cluster and lamellar structure. A series of jar tests were carried out to study the coagulation performance of PFC and PFS in phosphate-kaolin synthetic water treatment. Results showed that the coagulation performance of PFC was more efficient than PFS's in terms of the phosphorus removal efficiency and the residual turbidity. Due to using acetate as counter anion to iron, PFC is less harmful to the processes of water treatment and equipment than that of the conventional coagulants applied chlorides or sulfates. Therefore, PFC is a promising coagulant in the process of corrosion sensitive applications and the process of wastewater containing phosphorus treatment.
20 CFR 222.44 - Other relationship determinations for lump-sum payments.
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Other relationship determinations for lump... THE RAILROAD RETIREMENT ACT FAMILY RELATIONSHIPS Relationship as Parent, Grandchild, Brother or Sister... have the relationships to the employee shown below for lump-sum payment purposes: (a) Grandchildren. A...
Dark lump excitations in superfluid Fermi gases
Xu, Yan-Xia; Duan, Wen-Shan
2012-11-01
We study the linear and nonlinear properties of two-dimensional matter-wave pulses in disk-shaped superfluid Fermi gases. A Kadomtsev—Petviashvili I (KPI) solitary wave has been realized for superfluid Fermi gases in the limited cases of Bardeen—Cooper—Schrieffer (BCS) regime, Bose—Einstein condensate (BEC) regime, and unitarity regime. One-lump solution as well as one-line soliton solutions for the KPI equation are obtained, and two-line soliton solutions with the same amplitude are also studied in the limited cases. The dependence of the lump propagating velocity and the sound speed of two-dimensional superfluid Fermi gases on the interaction parameter are investigated for the limited cases of BEC and unitarity.
Dark lump excitations in superfluid Fermi gases
International Nuclear Information System (INIS)
Xu Yan-Xia; Duan Wen-Shan
2012-01-01
We study the linear and nonlinear properties of two-dimensional matter-wave pulses in disk-shaped superfluid Fermi gases. A Kadomtsev—Petviashvili I (KPI) solitary wave has been realized for superfluid Fermi gases in the limited cases of Bardeen—Cooper—Schrieffer (BCS) regime, Bose—Einstein condensate (BEC) regime, and unitarity regime. One-lump solution as well as one-line soliton solutions for the KPI equation are obtained, and two-line soliton solutions with the same amplitude are also studied in the limited cases. The dependence of the lump propagating velocity and the sound speed of two-dimensional superfluid Fermi gases on the interaction parameter are investigated for the limited cases of BEC and unitarity
Production and characterization of water treatment coagulant from ...
African Journals Online (AJOL)
Base on high cost in coagulant for treating both domestic and industrial water in the recent time. There is need to identify cheaper and efficient methods of removing contaminant as the demand for clean water increases. A study was carried out to investigate the use of locally sourced Kaolinite clay from Okefomo ...
International Nuclear Information System (INIS)
Whitney, K G; Dasgupta, A; Davis, J; Coverdale, C A
2007-01-01
Two atomic models of the population dynamics of substates within the n 4 and n = 3 multiplets of nickel-like tungsten and beryllium-like iron, respectively, are described in this paper. The flexible atomic code (FAC) is used to calculate the collisional and radiative couplings and energy levels of the excited states within these ionization stages. These atomic models are then placed within larger principal-quantum-number-based ionization dynamic models of both tungsten and iron plasmas. Collisional-radiative equilibrium calculations are then carried out using these models that demonstrate how the multiplet substates depart from local thermodynamic equilibrium (LTE) as a function of ion density. The effect of these deviations from LTE on the radiative and collisional deexcitation rates of lumped 3s, 3p, 3d, 4s, 4p, 4d and 4f states is then calculated and least-squares fits to the density dependence of these lumped-state rate coefficients are obtained. The calculations show that, with the use of lumped-state models (which are in common use), one can accurately model the L- and M-shell ionization dynamics occurring in present-day Z-pinch experiments only through the addition of these extra, non-LTE-induced, rate coefficient density dependences. However, the derivation and use of low-order polynomial fits to these density dependences makes lumped-state modelling both viable and of value for post-processing analyses
Incidence of malignancy in females presenting with breast lumps in OPD: a study of 277 cases
International Nuclear Information System (INIS)
Chaudhary, I.A.; Qureshi, S.K.; Rasul, S.
2003-01-01
Objective: To find the incidence of malignancy in females presenting with breast lumps in surgical out patient and to find out the age related incidence of benign and malignant diseases in these patients. Patients and Methods: All cases reporting to surgical outdoor with breast lumps were included and underwent investigation for the breast lumps to determine the histopathological diagnosis. Results: A total of 277 cases were studied. 24.2% breast lumps were malignant and 75.8% were benign. The incidence of malignancy increases from 0% in 2nd decade to 38.9% in 5th and 100% in 9th decade of life. The probability of diagnosing a breast lump as a malignant is one in three in 4th decade, two in five in 5th decade and more than one in two there after. Fibrocystic disease (33.8%) and Fibro adenoma (27.1%) was the commonest finding among the benign lumps. Among malignant lumps infiltrating duct carcinoma (68.7%) is the commonest finding. Conclusion: There is a significantly high incidence of malignant breast lumps after the 3rd decade of life and it increases subsequently. It is recommended that the surgeon managing a case of breast lump in a patient above 30 years should be highly suspicious and cautious so that early detection and management of malignant lumps be carried out. (author)
Directory of Open Access Journals (Sweden)
Hoong Ho Nicholas Jian
2018-01-01
Full Text Available The conventional process to treat dye wastewater is the physicochemical treatment such as coagulation, flocculation and adsorption process. A new approach has been demonstrated to treat Congo red dye wastewater, which is the adsorption-coagulation hybrid process. Natural coagulant extracted from Hibiscus sabdariffa seeds is used as the coagulant while activated carbon is used as the adsorbent in this case study. The objective of this experiment is to study the significant factors that will affect the efficiency of dye removal. Then, the optimum conditions for the hybrid process is determined using Respond Surface Methodology (RSM. The variables are pH, initial dye concentration, coagulant dosage and adsorbent dosage while the response of experiment is the dye removal percentage. A three-level and four-variable Box-Behnken design (BBD is used for the RSM. A total of 27 sets of experimental results is required to determine the optimum conditions. Jar test is used to conduct the experiment with the addition of coagulant and adsorbent simultaneously. Based on the regression model analysis and ANOVA, the highly significant factors that contribute to the dye removal efficiency through adsorption-coagulation hybrid process are pH of solution and initial dye concentration. The RSM results shows that the optimised process parameters for adsorption-coagulation hybrid process with Hibiscus sabdariffa seeds as the coagulant and activated carbon as the adsorbent are pH 2, initial dye concentration of 385 ppm, coagulant dosage of 209 mg/L and adsorbent dosage of 150 mg/L. The dye removal reaches up to 96.67% under optimum parameters.
Directory of Open Access Journals (Sweden)
Šćiban Marina B.
2010-01-01
Full Text Available Coagulation and flocculation by adding chemicals are the methods that are usually used for removal of water turbidity. This study is concerned with the coagulation activity of extracts of various strains of bean. The aim was to ascertain if bean varieties influence coagulation activity. Active components were extracted from 1 g of ground sample with 100 ml distilled water. Contents of dry matter and nitrogen were specified in the solid samples, and the content of soluble nitrogen was determined in the extracts. These data were used to calculate the efficiency of extraction of nitrogen-containing compounds. The coagulation activity was assessed by jar test using synthetic turbid water, of the initial pH 9 and turbidity 35 NTU. The jar test was carried out by adding different amounts of extracts to model water, and stirring the content. After sedimentation for 1 h, residual turbidity was determined by turbidimeter and coagulation activity was calculated. The increment of organic matter concentration after the coagulation was also determined. These experiments confirmed that extracts of all investigated strains of bean could be used successfully as natural coagulants.
Directory of Open Access Journals (Sweden)
Y. Tang
2007-01-01
Full Text Available This study seeks to identify sensitivity tools that will advance our understanding of lumped hydrologic models for the purposes of model improvement, calibration efficiency and improved measurement schemes. Four sensitivity analysis methods were tested: (1 local analysis using parameter estimation software (PEST, (2 regional sensitivity analysis (RSA, (3 analysis of variance (ANOVA, and (4 Sobol's method. The methods' relative efficiencies and effectiveness have been analyzed and compared. These four sensitivity methods were applied to the lumped Sacramento soil moisture accounting model (SAC-SMA coupled with SNOW-17. Results from this study characterize model sensitivities for two medium sized watersheds within the Juniata River Basin in Pennsylvania, USA. Comparative results for the 4 sensitivity methods are presented for a 3-year time series with 1 h, 6 h, and 24 h time intervals. The results of this study show that model parameter sensitivities are heavily impacted by the choice of analysis method as well as the model time interval. Differences between the two adjacent watersheds also suggest strong influences of local physical characteristics on the sensitivity methods' results. This study also contributes a comprehensive assessment of the repeatability, robustness, efficiency, and ease-of-implementation of the four sensitivity methods. Overall ANOVA and Sobol's method were shown to be superior to RSA and PEST. Relative to one another, ANOVA has reduced computational requirements and Sobol's method yielded more robust sensitivity rankings.
Preparation of lumped fission product (FP) cross sections for a multigroup library
International Nuclear Information System (INIS)
Ono, S.; Corcuera, R.P.
1984-01-01
A method for the calculation of lumped Fission Product (FP) cross sections has been developed. The group constants fo each nuclide are generated by NJOY code, based on ENDF/B-V data. In this first version, cross section of 28 nuclides are lumped for typical characteristics of Binary Breeder Reactor (BBR). One energy group calculations are made for a 1000 MWe fast reactor to verify the influence of burnup, number of FP and fuel composition on the lumped fission product cross sections. (Author) [pt
Reduction in thermal conductivity of BiSbTe lump
Energy Technology Data Exchange (ETDEWEB)
Ahmad, Kaleem [King Saud University, Sustainable Energy Technologies Center, College of Engineering, PO Box 800, Riyadh (Saudi Arabia); Wan, C. [Tsinghua University, State Key Laboratory of New Ceramics and Fine Processing, School of Materials Science and Engineering, Beijing (China); Al-Eshaikh, M.A.; Kadachi, A.N. [King Saud University, Research Center, College of Engineering, PO Box 800, Riyadh (Saudi Arabia)
2017-03-15
In this work, systematic investigations on the thermal conductivities of BiSbTe lump, microstructured pristine BiSbTe bulk and single wall carbon nanotubes (SWCNTs)/BiSbTe bulk nanocomposites were performed. BiSbTe lumps were crushed to form a coarse powder (200 μm) and effect of particle size reduction on the effective thermal conductivity of BiSbTe (200 μm) bulk were analyzed. For further reduction in the conductivity, a two pronged strategy has been employed. First, additional refinement of BiSbTe (200 μm) were performed through ball milling in an inert environment. Second, SWCNTs in 0.75, and 1.0 vol% were distributed uniformly in the fine BiSbTe ball milled powder. The results showed that the effective thermal conductivities decrease with the reduction in the particle size from lump to BiSbTe (200 μm) bulk as well as with the addition of SWCNTs accompanied by further refinement of BiSbTe particles. The significant reduction in thermal conductivities of the lump was achieved for pure BiSbTe (200 μm) bulk and 0.75 vol% of SWCNTs/BiSbTe composite. This can be ascribed to the enhanced phonon scattering by the grain boundaries between the nanostructured BiSbTe particles as well as the interfaces between BiSbTe and the low dimensional carbon nanotubes. (orig.)
Exploration by radioactive fibrinogen of intrarenal coagulation phenomena. Preliminary results
International Nuclear Information System (INIS)
Simon, Jacques.
1974-01-01
The participation of fibrin deposits in kidney pathology was studied by the use of a radioactive tracer involved in the coagulation phenomenon: iodine 131-labelled fibrinogen. The isotopic exploration consists of a fibrinogen kinetics study combined with external counting over the kidney regions. The different stages of the procedure are described: separation, purification and labelling of fibrinogen; characteristics of the radioactive fibrinogen used; practical details of the examination itself; data analysis method. A chapter devoted to verifications and discussions of the procedure is followed by a report on the exploration of intrarenal coagulation phenomena in 30 kidney disease patients. In conclusion, the study of fibrinogen kinetics is considered as the most suitable method to detect local or slight intravascular coagulation phenomena. The sensitivity of the isotopic exploration is very satisfactory. The main criticism directed against this method is that the exploration is general and therefore blind [fr
OPTIMIZATION OF FLOCCULATION PROCESS BY MICROBIAL COAGULANT IN RIVER WATER
Directory of Open Access Journals (Sweden)
Fatin Nabilah Murad
2017-12-01
Full Text Available The existing process of coagulation and flocculation are using chemicals that known as cationic coagulant such as alum, ferric sulfate, calcium oxide, and organic polymers. Thus, this study concentrates on optimizing of flocculation process by microbial coagulant in river water. Turbidity and suspended solids are the main constraints of river water quality in Malaysia. Hence, a study is proposed to produce microbial coagulants isolated locally for river water treatment. The chosen microbe used as the bioflocculant producer is Aspergillus niger. The parameters to optimization in the flocculation process were pH, bioflocculant dosage and effluent concentration. The research was done in the jar test process and the process parameters for maximum turbidity removal was validated. The highest flocculating activity was obtained on day seven of cultivation in the supernatant. The optimum pH and bioflocculant dosage for an optimize sedimentation process were between 4-5 and 2-3 mL for 0.3 g/L of effluent concentration respectively. The model was validated by using a river water sample from Sg. Pusu and the result showed that the model was acceptable to evaluate the bioflocculation process.
Energy Technology Data Exchange (ETDEWEB)
Santana, C.R.; Pereira, D.F.; Sousa, S.C S N.; Silva, G.F. [Universidade Federal de Sergipe (UFSE), Sao Cristovao, SE (Brazil). Dept. de Engenharia Quimica], e-mail: claudia@ufs.br; Cavalcanti, E.B. [Universidade Tiradentes (UNIT), SE (Brazil). Inst. de Tecnologia e Pesquisa
2010-07-15
In the lifetime of an oil well, there comes a moment when a lot of water begins to be produced along with oil, either by the conditions of the reservoir, or as a result of water injection in the secondary recovery of the well. An important step in such process involves the treatment of the produced water by means of coagulation techniques. Therefore, the use of environmentally correct coagulants is presented as a viable alternative and has demonstrated advantages over the use of chemical coagulants. The plant of the genus Moringa, whose species is oleifera Lam, stands out as one of the most promising natural coagulants. The present study investigated the evaluation of the coagulation/flocculation of produced water, using seeds of Moringa oleifera Lam. as coagulant. The results were very significant, demonstrating that Moringa oleifera Lam. can be used as a natural coagulant in this type of treatment. (author)
Directory of Open Access Journals (Sweden)
V. E. Avakov
2015-01-01
Full Text Available Systemic therapeutic hypothermia has gained a negative reputation in treating multiple trauma patients and is regarded as one of the factors in the lethal triad of shock, acidosis, and hypothermia. This fact owes to no relationship between acidosis and hypothermia; the effects of the latter on coagulation are evident and complexly reversible in the presence of acidosis.Objective: to determine the impact of noninvasive local brain cooling on the metabolic and blood coagulation indicators of a patient with acute cerebral ischemia.Subjects and methods. The subjects of the study were 113 patients with severe brain injury, including that complicated by the involvement of stem structures, who underwent brain cooling in different modifications. In so doing, the val ues of acidbase balance and coagulation system in arterial and venous blood were investigated.Results. Local brain hypother mia was not found to affect coagulation while the baseline negative values of excess buffer bases showed positive values (a right shift by the end of cooling. Recommendations were given to prevent metabolic shifts.Conclusion. Patients at very high risk for bleeding may be safely cooled to a brain temperature of 32—34°C even in the presence of moderatetosevere acidosis. This is a great advantage of local hypothermia over systemic one.
29 CFR Appendix A to Part 4022 - Lump Sum Mortality Rates
2010-07-01
... 29 Labor 9 2010-07-01 2010-07-01 false Lump Sum Mortality Rates A Appendix A to Part 4022 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY CORPORATION COVERAGE AND BENEFITS BENEFITS PAYABLE IN TERMINATED SINGLE-EMPLOYER PLANS Pt. 4022, App. A Appendix A to Part 4022—Lump Sum Mortality...
Hu, Wenchao; Wu, Chunde
2016-01-01
The feasibility of using enhanced coagulation, which combined polyaluminum chloride (PAC) with diatomite for improving coagulation performance and reducing the residual aluminum (Al), was discussed. The effects of PAC and diatomite dosage on the coagulation performance and residual Al were mainly investigated. Results demonstrated that the removal efficiencies of turbidity, dissolved organic carbon (DOC), and UV254 were significantly improved by the enhanced coagulation, compared with PAC coagulation alone. Meaningfully, the five forms of residual Al (total Al (TAl), total dissolved Al (TDAl), dissolved organic Al (DOAl), dissolved monomeric Al (DMAl), and dissolved organic monomeric Al (DOMAl)) all had different degrees of reduction in the presence of diatomite and achieved the lowest concentrations (0.185, 0.06, 0.053, 0.014, and 0 mg L(-1), respectively) at a PAC dose of 15 mg L(-1) and diatomite dose of 40 mg L(-1). In addition, when PAC was used as coagulant, the majority of residual Al existed in dissolved form (about 31.14-70.16%), and the content of DOMAl was small in the DMAl.
Blood coagulation and the risk of atherothrombosis: a complex relationship
Directory of Open Access Journals (Sweden)
van der Voort Danielle
2004-12-01
Full Text Available Abstract The principles of Virchov's triad appear to be operational in atherothrombosis or arterial thrombosis: local flow changes and particularly vacular wall damage are the main pathophysiological elements. Furthermore, alterations in arterial blood composition are also involved although the specific role and importance of blood coagulation is an ongoing matter of debate. In this review we provide support for the hypothesis that activated blood coagulation is an essential determinant of the risk of atherothrombotic complications. We distinguish two phases in atherosclerosis: In the first phase, atherosclerosis develops under influence of "classical" risk factors, i.e. both genetic and acquired forces. While fibrinogen/fibrin molecules participate in early plaque lesions, increased activity of systemic coagulation is of no major influence on the risk of arterial thrombosis, except in rare cases where a number of specific procoagulant forces collide. Despite the presence of tissue factor – factor VII complex it is unlikely that all fibrin in the atherosclerotic plaque is the direct result from local clotting activity. The dominant effect of coagulation in this phase is anticoagulant, i.e. thrombin enhances protein C activation through its binding to endothelial thrombomodulin. The second phase is characterized by advancing atherosclerosis, with greater impact of inflammation as indicated by an elevated level of plasma C-reactive protein, the result of increased production influenced by interleukin-6. Inflammation overwhelms protective anticoagulant forces, which in itself may have become less efficient due to down regulation of thrombomodulin and endothelial cell protein C receptor (EPCR expression. In this phase, the inflammatory drive leads to recurrent induction of tissue factor and assembly of catalytic complexes on aggregated cells and on microparticles, maintaining a certain level of thrombin production and fibrin formation. In advanced
Fundamentals of electromagnetics 1 internal behavior of lumped elements
Voltmer, David
2007-01-01
This book is the first of two volumes which have been created to provide an understanding of the basic principles and applications of electromagnetic fields for electrical engineering students. Fundamentals of Electromagnetics Vol 1: Internal Behavior of Lumped Elements focuses upon the DC and low-frequency behavior of electromagnetic fields within lumped elements. The properties of electromagnetic fields provide the basis for predicting the terminal characteristics of resistors, capacitors, and inductors. The properties of magnetic circuits are included as well. For slightly higher frequencie
Theories of blood coagulation.
Riddel, James P; Aouizerat, Bradley E; Miaskowski, Christine; Lillicrap, David P
2007-01-01
Although the concept of the coagulation cascade represented a significant advance in the understanding of coagulation and served for many years as a useful model, more recent clinical and experimental observations demonstrate that the cascade/waterfall hypothesis does not fully and completely reflect the events of hemostasis in vivo. The goal of this article is to review the evolution of the theories of coagulation and their proposed models to serve as a tool when reviewing the research and practice literature that was published in the context of these different theories over time.
A correction technique for the dispersive effects of mass lumping for transport problems
Guermond, Jean-Luc
2013-01-01
This paper addresses the well-known dispersion effect that mass lumping induces when solving transport-like equations. A simple anti-dispersion technique based on the lumped mass matrix is proposed. The method does not require any non-trivial matrix inversion and has the same anti-dispersive effects as the consistent mass matrix. A novel quasi-lumping technique for P2 finite elements is introduced. Higher-order extensions of the method are also discussed. © 2012 Elsevier B.V.
The lumped parameter model for fuel pins
Energy Technology Data Exchange (ETDEWEB)
Liu, W S [Ontario Hydro, Toronto, ON (Canada)
1996-12-31
The use of a lumped fuel-pin model in a thermal-hydraulic code is advantageous because of computational simplicity and efficiency. The model uses an averaging approach over the fuel cross section and makes some simplifying assumptions to describe the transient equations for the averaged fuel, fuel centerline and sheath temperatures. It is shown that by introducing a factor in the effective fuel conductivity, the analytical solution of the mean fuel temperature can be modified to simulate the effects of the flux depression in the heat generation rate and the variation in fuel thermal conductivity. The simplified analytical method used in the transient equation is presented. The accuracy of the lumped parameter model has been compared with the results from the finite difference method. (author). 4 refs., 2 tabs., 4 figs.
Xu, Jie; Zhao, Yanxia; Gao, Baoyu; Zhao, Qian
2018-05-01
The water eutrophication caused by cyanobacteria seasonally proliferates, which is a hot potato to be resolved for water treatment plants. This study firstly investigated coagulation performance of titanium tetrachloride (TiCl 4 ) for Microcystis aeruginosa synthetic water treatment. Results show complete algal cell removal by TiCl 4 coagulation without damage to cell membrane integrity even under harsh conditions; 60 mg/L TiCl 4 was effective in removing the microcystins up to 85%. Furthermore, besides having stronger UV 254 removal capability and the higher removal of fluorescent substances over Al- and Fe-based coagulants, TiCl 4 coagulant required more compact coagulation and sedimentation tanks due to its significantly improved floc growth and sedimentation speed. Meanwhile, its' short hydraulic retention time avoided algal cell breakage and subsequent algal organic matter release. Microcystin concentrations were kept at a low level during sludge storage period, indicating that the TiCl 4 flocs could prevent algal cells from natural lysis. To facilitate water recycling without secondary contamination, the algae-containing sludge after TiCl 4 coagulation ought to be disposed within 12 days at 20 °C and 8 days at 35 °C.
International Nuclear Information System (INIS)
An Chen; Su Jian
2011-01-01
Improved lumped parameter models were developed for the transient heat conduction in multi-layer composite slabs subjected to combined convective and radiative cooling. The improved lumped models were obtained through two-point Hermite approximations for integrals. Transient combined convective and radiative cooling of three-layer composite slabs was analyzed to illustrate the applicability of the proposed lumped models, with respect to different values of the Biot numbers, the radiation-conduction parameter, the dimensionless thermal contact resistances, the dimensionless thickness, and the dimensionless thermal conductivity. It was shown by comparison with numerical solution of the original distributed parameter model that the higher order lumped model (H 1,1 /H 0,0 approximation) yielded significant improvement of average temperature prediction over the classical lumped model. In addition, the higher order (H 1,1 /H 0,0 ) model was applied to analyze the transient heat conduction problem of steel-concrete-steel sandwich plates. - Highlights: → Improved lumped models for convective-radiative cooling of multi-layer slabs were developed. → Two-point Hermite approximations for integrals were employed. → Significant improvement over classical lumped model was achieved. → The model can be applied to high Biot number and high radiation-conduction parameter. → Transient heat conduction in steel-concrete-steel sandwich pipes was analyzed as an example.
Chokshi, Arati; Tielens, Alexander G. G. M.; Hollenbach, David
1989-01-01
Coagulation is an important mechanism in the growth of interstellar and interplanetary dust particles. The microphysics of the coagulation process was theoretically analyzed as a function of the physical properties of the coagulating grains, i.e., their size, relative velocities, temperature, elastic properties, and the van der Waal interaction. Numerical calculations of collisions between linear chains provide the wave energy in individual particles and the spectrum of the mechanical vibrations set up in colliding particles. Sticking probabilities are then calculated using simple estimates for elastic deformation energies and for the attenuation of the wave energy due to absorption and scattering processes.
An updated concept of coagulation with clinical implications.
Romney, Gregory; Glick, Michael
2009-05-01
Over the past century, a series of models have been put forth to explain the coagulation mechanism. The coagulation cascade/waterfall model has gained the most widespread acceptance. This model, however, has problems when it is used in different clinical scenarios. A more recently proposed cell-based model better describes the coagulation process in vivo and provides oral health care professionals (OHCPs) with a better understanding of the clinical implications of providing dental care to patients with potentially increased bleeding tendencies. The authors conducted a literature search using the PubMed database. They searched for key words including "coagulation," "hemostasis," "bleeding," "coagulation factors," "models," "prothrombin time," "activated partial thromboplastin time," "international normalized ratio," "anticoagulation therapy" and "hemophilia" separately and in combination. The coagulation cascade/waterfall model is insufficient to explain coagulation in vivo, predict a patient's bleeding tendency, or correlate clinical outcomes with specific laboratory screening tests such as prothrombin time, activated partial thromboplastin time and international normalized ratio. However, the cell-based model of coagulation that reflects the in vivo process of coagulation provides insight into the clinical ramifications of treating dental patients with specific coagulation factor deficiencies. Understanding the in vivo coagulation process will help OHCPs better predict a patient's bleeding tendency. In addition, applying the theoretical concept of the cell-based model of coagulation to commonly used laboratory screening tests for coagulation and bleeding will result in safer and more appropriate dental care.
A correction technique for the dispersive effects of mass lumping for transport problems
Guermond, Jean-Luc; Pasquetti, Richard
2013-01-01
This paper addresses the well-known dispersion effect that mass lumping induces when solving transport-like equations. A simple anti-dispersion technique based on the lumped mass matrix is proposed. The method does not require any non-trivial matrix
Cross sections of the lumped fission products for the AMZ library
International Nuclear Information System (INIS)
Ono, S.; Corcueca, R.P.; Nascimento, J.A.
1985-01-01
The preparation of the lumped fission product cross section for the AMZ library is described. For this purpose 100 nuclides were selected. The cross sections for each nuclide were generated by the NJOY code with evaluated nuclear data from ENDF/B-V, complemented with ENDF/B-IV data. A comparison is performed between the data obtained and the lumped fission product cross section of JFS-II [pt
Directory of Open Access Journals (Sweden)
Mahmud Mahmud
2016-06-01
Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.
Directory of Open Access Journals (Sweden)
Mahmud Mahmud
2013-11-01
Full Text Available The primary problem encountered in the application of membrane technology was membrane fouling. During this time, hybrid process by coagulation-ultrafiltration in drinking water treatment that has been conducted by some research, using by one-stage coagulation. The goal of this research was to investigate the effect of two-stage coagulation as a pretreatment towards performance of the coagulation-ultrafiltration hybrid process for removal NOM in the peat water. Coagulation process, either with the one-stage or two-stage coagulation was very good in removing charge hydrophilic fraction, i.e. more than 98%. NOM fractions of the peat water, from the most easily removed by the two-stage coagulation and one-stage coagulation process was charged hydrophilic>strongly hydrophobic>weakly hydrophobic>neutral hydrophilic. The two-stage coagulation process could removed UV254 and colors with a little better than the one-stage coagulation at the optimum coagulant dose. Neutral hydrophilic fraction of peat water NOM was the most influential fraction of UF membrane fouling. The two-stage coagulation process better in removing the neutral hidrophilic fraction, while removing of the charged hydrophilic, strongly hydrophobic and weakly hydrophobic similar to the one-stage coagulation. Hybrid process by pretreatment with two-stage coagulation, beside can increased removal efficiency of UV254 and color, also can reduced fouling rate of the ultrafiltration membraneIt must not exceed 250 words, contains a brief summary of the text, covering the whole manuscript without being too elaborate on every section. Avoid any abbreviation, unless it is a common knowledge or has been previously stated.
Lumped-Parameter Models for Windturbine Footings on Layered Ground
DEFF Research Database (Denmark)
Andersen, Lars
The design of modern wind turbines is typically based on lifetime analyses using aeroelastic codes. In this regard, the impedance of the foundations must be described accurately without increasing the overall size of the computationalmodel significantly. This may be obtained by the fitting...... of a lumped-parameter model to the results of a rigorous model or experimental results. In this paper, guidelines are given for the formulation of such lumped-parameter models and examples are given in which the models are utilised for the analysis of a wind turbine supported by a surface footing on a layered...
Generalized Kutta–Joukowski theorem for multi-vortex and multi-airfoil flow (a lumped vortex model
Directory of Open Access Journals (Sweden)
Bai Chenyuan
2014-02-01
Full Text Available For purpose of easy identification of the role of free vortices on the lift and drag and for purpose of fast or engineering evaluation of forces for each individual body, we will extend in this paper the Kutta–Joukowski (KJ theorem to the case of inviscid flow with multiple free vortices and multiple airfoils. The major simplification used in this paper is that each airfoil is represented by a lumped vortex, which may hold true when the distances between vortices and bodies are large enough. It is found that the Kutta–Joukowski theorem still holds provided that the local freestream velocity and the circulation of the bound vortex are modified by the induced velocity due to the outside vortices and airfoils. We will demonstrate how to use the present result to identify the role of vortices on the forces according to their position, strength and rotation direction. Moreover, we will apply the present results to a two-cylinder example of Crowdy and the Wagner example to demonstrate how to perform fast force approximation for multi-body and multi-vortex problems. The lumped vortex assumption has the advantage of giving such kinds of approximate results which are very easy to use. The lack of accuracy for such a fast evaluation will be compensated by a rigorous extension, with the lumped vortex assumption removed and with vortex production included, in a forthcoming paper.
Experimental Verification of Guided-Wave Lumped Circuits Using Waveguide Metamaterials
Li, Yue; Zhang, Zhijun
2018-04-01
Through the construction and characterization in microwave frequencies, we experimentally demonstrate our recently developed theory of waveguide lumped circuits, i.e., waveguide metatronics [Sci. Adv. 2, e1501790 (2016), 10.1126/sciadv.1501790], as a method to design subwavelength-scaled analog circuits. In the paradigm of waveguide metatronics, numbers of lumped inductors and capacitors are easily integrated functionally inside the waveguide, which is an irreplaceable transmission line in millimeter-wave and terahertz systems with the advantages of low radiation loss and low crosstalk. An example of multiple-ordered metatronic filters with layered structures is fabricated utilizing the technique of substrate integrated waveguides, which can be easily constructed by the printed-circuit-board process. The materials used in the construction are also typical microwave materials with positive permittivity, low loss, and negligible dispersion, imitating the plasmonic materials with negative permittivity in the optical domain. The results verify the theory of waveguide metatronics, which provides an efficient platform of functional lumped circuit design for guided-wave processing.
Directory of Open Access Journals (Sweden)
Nora SEGHAIRI
2017-12-01
Full Text Available Domestic wastewater treatment by coagulation-flocculation is widely used internationally. This treatment reduces color and turbidity, indicating organic and inorganic contaminants, but at acceptable levels for treated waste water discharged into the receiving environment. The objective of this study is to optimize the treatment of wastewater by coagulation-flocculation using aluminum sulphate as a coagulant. Various reaction parameters are taken into account, such as the coagulant dose, the pH of the solutions, the conductivity, the BOD5, the nitrates, the ammonium and the phosphates. We found from the different results obtained the optimal dose of aluminum sulphate is 400 mg/l with a reduction of 96.31%, 82.44% 90.95% and 78.74% respectively for phosphates, nitrates, ammonium and BOD5. It is recognized that pH influences the abatement rates of pollution contained in wastewater. For each water, there is a pH range for which coagulation- flocculation takes place rapidly. For our study, the optimum pH for removal of BOD5 and ammonium is between 6 and 7.
Microwave tissue coagulation: effects of power and treatment time on coagulation size
International Nuclear Information System (INIS)
Kang, Seung Pyung; Kim, Young Hwan; Park, Dong Man; Kim, Jeong Seok; Park, Seo Young; Cha, Soon Joo; Hur, Gham
1999-01-01
To determine the effects of power and coagulation time on lesion size of ex-vivo bovine liver using microwaves. Six bovine livers were divided into two groups (first group : 30W output, second group : 60W output) and microwave coagulation was performed for 30, 60, and 120 sec. Thermal injury site was then observed by means of sonography, and the maximal transverse diameter of the echo-change portion after microwave coagulation was measured. On the section of specimen, maximal transverse diameters of the thermal injury site were measured by gross inspection and compared with the result of sonographic measurement. Maximal transverse diameters of hyperechoic lesions of the first group, as seen on sonography, were 8.3mm, 12.2mm, and 15.6mm, and the maximal transverse diameters of thermal injury sites on gross specimens were 9.1mm, 12.0mm, and 15.1mm, respectively. Maximal transverse diameters of hyperechoic lesions of the second group, as seen on sonography, were 12.1mm, 17.4mm, and 21.2mm and maximal transverse diameters of thermal injury sites on gross specimens were 13.2mm, 16.0mm, and 20.0mm, respectively. Statistically maximal transverse diameters of hyperechoic lesions, as seen on sonography, correlated closely with the gross findings of maximal transverse diameters of thermal injury sites (P < .05). Maximal transverse diameters of thermal injury sites were significantly increased as the output of the microwave coagulator and the duration of coagulation time increased (P < .05)
24 CFR 570.513 - Lump sum drawdown for financing of property rehabilitation activities.
2010-04-01
... DEVELOPMENT BLOCK GRANTS Grant Administration § 570.513 Lump sum drawdown for financing of property... 24 Housing and Urban Development 3 2010-04-01 2010-04-01 false Lump sum drawdown for financing of property rehabilitation activities. 570.513 Section 570.513 Housing and Urban Development Regulations...
Cutting and coagulation during intraoral soft tissue surgery using Er: YAG laser.
Onisor, I; Pecie, R; Chaskelis, I; Krejci, I
2013-06-01
To find the optimal techniques and parameters that enables Er:YAG laser to be used successfully for small intraoral soft tissue interventions, in respect to its cutting and coagulation abilities. In vitro pre-tests: 4 different Er:YAG laser units and one CO2 unit as the control were used for incision and coagulation on porcine lower jaws and optimal parameters were established for each type of intervention and each laser unit: energy, frequency, type, pulse duration and distance. 3 different types of intervention using Er:YAG units are presented: crown lengthening, gingivoplasty and maxillary labial frenectomy with parameters found in the in vitro pre-tests. The results showed a great decrease of the EMG activity of masseter and anterior temporalis muscles. Moreover, the height and width of the chewing cycles in the frontal plane increased after therapy. Er:YAG is able to provide good cutting and coagulation effects on soft tissues. Specific parameters have to be defined for each laser unit in order to obtain the desired effect. Reduced or absent water spray, defocused light beam, local anaesthesia and the most effective use of long pulses are methods to obtain optimal coagulation and bleeding control.
Emergent self-similarity of cluster coagulation
Pushkin, Dmtiri O.
A wide variety of nonequilibrium processes, such as coagulation of colloidal particles, aggregation of bacteria into colonies, coalescence of rain drops, bond formation between polymerization sites, and formation of planetesimals, fall under the rubric of cluster coagulation. We predict emergence of self-similar behavior in such systems when they are 'forced' by an external source of the smallest particles. The corresponding self-similar coagulation spectra prove to be power laws. Starting from the classical Smoluchowski coagulation equation, we identify the conditions required for emergence of self-similarity and show that the power-law exponent value for a particular coagulation mechanism depends on the homogeneity index of the corresponding coagulation kernel only. Next, we consider the current wave of mergers of large American banks as an 'unorthodox' application of coagulation theory. We predict that the bank size distribution has propensity to become a power law, and verify our prediction in a statistical study of the available economical data. We conclude this chapter by discussing economically significant phenomenon of capital condensation and predicting emergence of power-law distributions in other economical and social data. Finally, we turn to apparent semblance between cluster coagulation and turbulence and conclude that it is not accidental: both of these processes are instances of nonlinear cascades. This class of processes also includes river network formation models, certain force-chain models in granular mechanics, fragmentation due to collisional cascades, percolation, and growing random networks. We characterize a particular cascade by three indicies and show that the resulting power-law spectrum exponent depends on the indicies values only. The ensuing algebraic formula is remarkable for its simplicity.
A preliminary study of opuntia stricta as a coagulant for turbidity removal in surface waters
International Nuclear Information System (INIS)
Mukhtar, A.
2015-01-01
Natural polymers, extracted from plants, can be used as coagulants for water treatment in addition to metal salts and synthetic polymers. Natural materials may offer benefits such as local production, lesser health hazards and affordability for developing world. Opuntia stricta plant, a cactus specie native to Mexico, has been explored in this study for its efficacy as coagulant. Efficiency of Opuntia stricta was assessed on the basis of turbidity removal from lab prepared and surface water samples. The effect of water pH on its performance was also analyzed. The study results revealed that removal efficiency of Opuntia stricta for turbidity removal remains consistent within a wide pH range (pH 5 to 10), in contrast to other coagulants which are pH dependent. Furthermore, pH of the water remains constant during coagulation and pH adjustment may not be required for subsequent treatment processes, which is often needed in case metal coagulants are used. Residual turbidity below 20 NTU is conveniently achieved by using Opuntia stricta even when it is used at very low doses. Formation of exceptionally large flocs and their linear configuration reveals the possibility that mechanism of coagulation by Opuntia stricta is adsorption and inter-particle bridging. (author)
A distributed lumped active all-pass network configuration.
Huelsman, L. P.; Raghunath, S.
1972-01-01
In this correspondence a new and interesting distributed lumped active network configuration that realizes an all-pass network function is described. A design chart for determining the values of the network elements is included.
Lumped-parameters equivalent circuit for condenser microphones modeling.
Esteves, Josué; Rufer, Libor; Ekeom, Didace; Basrour, Skandar
2017-10-01
This work presents a lumped parameters equivalent model of condenser microphone based on analogies between acoustic, mechanical, fluidic, and electrical domains. Parameters of the model were determined mainly through analytical relations and/or finite element method (FEM) simulations. Special attention was paid to the air gap modeling and to the use of proper boundary condition. Corresponding lumped-parameters were obtained as results of FEM simulations. Because of its simplicity, the model allows a fast simulation and is readily usable for microphone design. This work shows the validation of the equivalent circuit on three real cases of capacitive microphones, including both traditional and Micro-Electro-Mechanical Systems structures. In all cases, it has been demonstrated that the sensitivity and other related data obtained from the equivalent circuit are in very good agreement with available measurement data.
Energy Technology Data Exchange (ETDEWEB)
Jin, Xin [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Jin, Pengkang, E-mail: pkjin@hotmail.com [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Hou, Rui [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China); Yang, Lei [Department of Materials Science and Engineering, Monash University, Clayton, VIC, 3800 (Australia); Wang, Xiaochang C., E-mail: xcwang@xauat.edu.cn [School of Environmental and Municipal Engineering, Xi’an University of Architecture and Technology, Xi’an, Shaanxi Province, 710055 (China)
2017-04-05
Highlights: • A novel HOC process was firstly put forward to apply in wastewater reclamation. • Interactions between ozone and Al-based coagulants was found in the HOC process. • Ozonation can be catalyzed and enhanced by Al-based coagulants in the HOC process. • HOC process showed better organics removal than pre-ozonation-coagulation process. - Abstract: A novel hybrid ozonation-coagulation (HOC) process was developed for application in wastewater reclamation. In this process, ozonation and coagulation occurred simultaneously within a single unit. Compared with the conventional pre-ozonation-coagulation process, the HOC process exhibited much better performance in removing dissolved organic matters. In particular, the maximal organic matters removal efficiency was obtained at the ozone dosage of 1 mgO{sub 3}/mg DOC at each pH value (pH 5, 7 and 9). In order to interpret the mechanism of the HOC process, ozone decomposition was monitored. The results indicated that ozone decomposed much faster in the HOC process. Moreover, by using the reagent of O{sub 3}-resistant hydroxyl radical (·OH) probe compound, para-chlorobenzoic acid (pCBA), and electron paramagnetic resonance (EPR) analysis, it was observed that the HOC process generated higher content of ·OH compared with pre-ozonation process. This indicates that the ·OH oxidation reaction as the key step can be catalyzed and enhanced by Al-based coagulants and their hydrolyzed products in this developed process. Thus, based on the catalytic effects of Al-based coagulants on ozonation, the HOC process provides a promising alternative to the conventional technology for wastewater reclamation in terms of higher efficiency.
Lumped parametric model of the human ear for sound transmission.
Feng, Bin; Gan, Rong Z
2004-09-01
A lumped parametric model of the human auditoria peripherals consisting of six masses suspended with six springs and ten dashpots was proposed. This model will provide the quantitative basis for the construction of a physical model of the human middle ear. The lumped model parameters were first identified using published anatomical data, and then determined through a parameter optimization process. The transfer function of the middle ear obtained from human temporal bone experiments with laser Doppler interferometers was used for creating the target function during the optimization process. It was found that, among 14 spring and dashpot parameters, there were five parameters which had pronounced effects on the dynamic behaviors of the model. The detailed discussion on the sensitivity of those parameters was provided with appropriate applications for sound transmission in the ear. We expect that the methods for characterizing the lumped model of the human ear and the model parameters will be useful for theoretical modeling of the ear function and construction of the ear physical model.
THE RATIONALIZATION OF THE PARAMETERS OF MILK PROTEINS’ THERMO ACID COAGULATION BY BERRY COAGULANTS
Directory of Open Access Journals (Sweden)
Olena GREK
2017-03-01
Full Text Available This paper presents the results related to the influence of berry coagulant amount, its proactive acidity and duration of thermo acid coagulation on the process of milk proteins’ sedimentation. In the present work, the regression equations and response surface analysis were used to design and optimize an industrial bioprocess. Increase in the berry coagulant amount to 11 % and reduction of active acidity to 2.4 units were determined. pH up to 3 minutes is characterized by the highest processes of destabilization. Moreover, it improves the organoleptic properties and has the biggest impact on the yield of protein-berry clot (to 25 % and active acidity.
Magnetic particle imaging of blood coagulation
Energy Technology Data Exchange (ETDEWEB)
Murase, Kenya, E-mail: murase@sahs.med.osaka-u.ac.jp; Song, Ruixiao; Hiratsuka, Samu [Department of Medical Physics and Engineering, Division of Medical Technology and Science, Faculty of Health Science, Graduate School of Medicine, Osaka University, Osaka 565-0871 (Japan)
2014-06-23
We investigated the feasibility of visualizing blood coagulation using a system for magnetic particle imaging (MPI). A magnetic field-free line is generated using two opposing neodymium magnets and transverse images are reconstructed from the third-harmonic signals received by a gradiometer coil, using the maximum likelihood-expectation maximization algorithm. Our MPI system was used to image the blood coagulation induced by adding CaCl{sub 2} to whole sheep blood mixed with magnetic nanoparticles (MNPs). The “MPI value” was defined as the pixel value of the transverse image reconstructed from the third-harmonic signals. MPI values were significantly smaller for coagulated blood samples than those without coagulation. We confirmed the rationale of these results by calculating the third-harmonic signals for the measured viscosities of samples, with an assumption that the magnetization and particle size distribution of MNPs obey the Langevin equation and log-normal distribution, respectively. We concluded that MPI can be useful for visualizing blood coagulation.
The frequency of malignancy in breast lumps on fnac in females under 35 years of age
International Nuclear Information System (INIS)
Iqbal, M.; Iqbal, M.
2014-01-01
Breast carcinoma is one of the common malignancies in females and its incidence is increasing in younger age. Diagnosis of carcinoma breast includes clinical evaluation, imaging and pathology. Fine Needle Aspiration Cytology is the first line pathological investigation in the diagnosis with excellent results. Objective: To determine the frequency of malignancy in breast lumps on FNAC in females under 35 years of age. Descriptive cross sectional study. Setting:Department of pathology Fatima Jinnah Medical College (FJMC), Lahore. Duration: Six months from 20th July, 2011 till 20th January, 2012.Methods: 150 female patients 35 years of age or less, presenting to the OPD and Indoor of Sir Ganga Ram Hospital Lahore, an affiliated hospital of FJMC Lahore, with breast lumps were included in the study. Demographic features and consent of the patients were noted. FNAC of the patients was performed as per advice of the consultant. Diagnosis of malignant cases was further confirmed on histology.Results: Out of all, 124 lumps (82.7%) were benign and 26 lumps (17.3%) were malignant. Amongst the benign lumps, 77(62.1%) were fibroadenomas, 28(22.6%) were fibrocystic changes, 08(06.5%) were inflammatory lesions, 07(05.6%) showed pyogenic abscess and 04 lumps (03.2%) were galactoceles. Amongst the malignant lumps, 22(84.6%) were ductal carcinoma, 02(07.7%) colloid carcinoma and 02(07.7%) were malignant phylloides. Conclusions: The frequency of malignancy in breast lumps in Pakistan is significantly high in females under 35 years of age. Appropriate measures are needed for prevention and early diagnosis and treatment in young females. (author)
CLINICO PATHOLOGICAL STUDY OF BENIGN BREAST LUMP – A HOSPITAL BASED STUDY
Directory of Open Access Journals (Sweden)
Anindita
2016-03-01
Full Text Available BACKGROUND Despite the fact that in majority of cases the initial symptom of benign breast disease is a lump, which can be easily detected by the patient herself by self-examination they generally present at a very late stage and this poses a great difficulty in their management. Early and appropriate diagnosis of breast disease is of utmost importance. AIM The aim of the study was to find out the relative frequency and commonest site of occurrence of benign breast disorder and their relationship with age, parity, menstrual cycle, and socio-economic status and also to find out the accuracy of investigative procedures in their diagnosis. DESIGN This is a cross sectional, interventional. Hospital based study. MATERIALS AND METHOD This study was done in 58 female patients in the age group 10 yrs. to 55 yrs. presenting with clinically benign breast lumps randomly chosen from outpatient department and indoor wards of The Calcutta Medical Research Institute, Kolkata. After taking an accurate history and proper clinical examination these patients were sequentially studied by radiological methods (Ultrasonography and mammography, fine needle aspiration cytology (FNAC and histopathology of removed specimen. Patients were enquired about their age, chief complaints, menstrual history, and use of oral pill, marital status, parity, lactation and socioeconomic status. RESULTS 79% of the benign breast lumps were found to be between 10–35 years, Fibro adenoma being the commonest one (41.38% and fibrocystic disease the second most common (29.31%. Breast lump were more common among unmarried and nulliparous females (48.27%, commonest site being upper and outer quadrant (38.8%. 69% patients were associated with an abnormal menstrual status. 76% of the cases were accurately diagnosed by clinical examination, 70% by mammography, 88% by FNAC and 84% by ultrasonography. CONCLUSION This clinicopathological study of benign breast lump is a small endeavour on our part
Lumped-Parameter Models for Wind-Turbine Footings on Layered Ground
DEFF Research Database (Denmark)
Andersen, Lars; Liingaard, Morten
2007-01-01
The design of modern wind turbines is typically based on lifetime analyses using aeroelastic codes. In this regard, the impedance of the foundations must be described accurately without increasing the overall size of the computational model significantly. This may be obtained by the fitting...... of a lumped-parameter model to the results of a rigorous model or experimental results. In this paper, guidelines are given for the formulation of such lumped-parameter models and examples are given in which the models are utilised for the analysis of a wind turbine supported by a surface footing on a layered...
Lumped parameter models for the interpretation of environmental tracer data
Energy Technology Data Exchange (ETDEWEB)
Maloszewski, P [GSF-Inst. for Hydrology, Oberschleissheim (Germany); Zuber, A [Institute of Nuclear Physics, Cracow (Poland)
1996-10-01
Principles of the lumped-parameter approach to the interpretation of environmental tracer data are given. The following models are considered: the piston flow model (PFM), exponential flow model (EM), linear model (LM), combined piston flow and exponential flow model (EPM), combined linear flow and piston flow model (LPM), and dispersion model (DM). The applicability of these models for the interpretation of different tracer data is discussed for a steady state flow approximation. Case studies are given to exemplify the applicability of the lumped-parameter approach. Description of a user-friendly computer program is given. (author). 68 refs, 25 figs, 4 tabs.
Lumped parameter models for the interpretation of environmental tracer data
International Nuclear Information System (INIS)
Maloszewski, P.; Zuber, A.
1996-01-01
Principles of the lumped-parameter approach to the interpretation of environmental tracer data are given. The following models are considered: the piston flow model (PFM), exponential flow model (EM), linear model (LM), combined piston flow and exponential flow model (EPM), combined linear flow and piston flow model (LPM), and dispersion model (DM). The applicability of these models for the interpretation of different tracer data is discussed for a steady state flow approximation. Case studies are given to exemplify the applicability of the lumped-parameter approach. Description of a user-friendly computer program is given. (author). 68 refs, 25 figs, 4 tabs
Hemorrhoidectomy: pedicle ligation vs pedicle coagulation
International Nuclear Information System (INIS)
Shaikh, B.S.; Balaoch, I.B.; Sohu, K.M.
2015-01-01
Objective: To compare the outcome of pedicle ligation vs pedicle coagulation haemorrhoidectomy. Methodology: This comparative prospective study was carried out at Department of Surgery, Ghulam Muhammad Maher Medcial College Hospital, Sukkur, Pakistan from January 2011 to January 2013 and included 300 patients of hemorrhoids. After routine workup, patients were randomly divided into two equal groups with one group receiving pedicle ligation and other pedicle coagulation for hemorrhoidectomy. Postoperatively they were followed for a period of 8 weeks for complications including pain, urinary retention, bleeding and anal stricture. Pain was recorded up to 10th postoperative day on the basis of visual analogue scale. Results: Mean age was 45 years and male to female ratio was 1.7:1. Mean operative time in pedicle ligation group was 15 min (range 14-20 min) and 17 min (15-25 min) in pedicle coagulation group. In Pedicle ligation group, pain was worst in 35 patients, moderate in 85 and mild in 30 patients; on the other hand in pedicle coagulation group, just 09 patients experienced worst pain. Urinary retention was observed in 44 patients in pedicle ligation group and 19 in pedicle coagulation group. Five patients in pedicle ligation group developed bleeding after their discharge from hospital; 7 patients in pedicle coagulation group reported secondary bleeding. Anal stricture was a rare complication and was found equally common in both the groups. Conclusion: Conventional hemorrhoidectomy with pedicle coagulation is an effective treatment modality for hemorrhoids and is associated with less chance of postoperative anal pain and urinary retention. (author)
Using a lumped conceptual hydrological model for five different catchments in Sweden
Ekenberg, Madeleine
2016-01-01
Hydrological models offer powerful tools for understanding and predicting. In this thesis we havereviewed the advantages and disadvantages of physically based distributed hydrological models andconceptually lumped hydrological models. Based on that review, we went into depth and developed aMATLAB code to test if a simple conceptual lumped hydrological model, namely GR2M, wouldperform satisfactory for five different catchments in different parts of Sweden. The model had ratherunsatisfactory re...
Coagulants modulate the hypocholesterolemic effect of tofu ...
African Journals Online (AJOL)
hope&shola
2006-02-02
Feb 2, 2006 ... The recent increase in soymilk and tofu (coagulated soymilk) consumption especially in western countries is due to the recognition of the health benefits of soy foods. The amount and the type of coagulated biomolecules (such as isoflavones) vary with the type of coagulant, and this will inevitable alter their ...
APPROACH TO THE DIAGNOSIS OF A BREAST LUMP
African Journals Online (AJOL)
breast cancer in any woman, irrespective of age.1,2 Fortunately, the vast majority of breast lumps are ... malignant breast lesions can be diagnosed in this way. When all aspects ... ultrasonography is the preferred modality for women under 35 ...
Uncovering and testing the fuzzy clusters based on lumped Markov chain in complex network.
Jing, Fan; Jianbin, Xie; Jinlong, Wang; Jinshuai, Qu
2013-01-01
Identifying clusters, namely groups of nodes with comparatively strong internal connectivity, is a fundamental task for deeply understanding the structure and function of a network. By means of a lumped Markov chain model of a random walker, we propose two novel ways of inferring the lumped markov transition matrix. Furthermore, some useful results are proposed based on the analysis of the properties of the lumped Markov process. To find the best partition of complex networks, a novel framework including two algorithms for network partition based on the optimal lumped Markovian dynamics is derived to solve this problem. The algorithms are constructed to minimize the objective function under this framework. It is demonstrated by the simulation experiments that our algorithms can efficiently determine the probabilities with which a node belongs to different clusters during the learning process and naturally supports the fuzzy partition. Moreover, they are successfully applied to real-world network, including the social interactions between members of a karate club.
Vannametee, E.; Karssenberg, D.; Hendriks, M. R.; de Jong, S. M.; Bierkens, M. F. P.
2010-05-01
We propose a modelling framework for distributed hydrological modelling of 103-105 km2 catchments by discretizing the catchment in geomorphologic units. Each of these units is modelled using a lumped model representative for the processes in the unit. Here, we focus on the development and parameterization of this lumped model as a component of our framework. The development of the lumped model requires rainfall-runoff data for an extensive set of geomorphological units. Because such large observational data sets do not exist, we create artificial data. With a high-resolution, physically-based, rainfall-runoff model, we create artificial rainfall events and resulting hydrographs for an extensive set of different geomorphological units. This data set is used to identify the lumped model of geomorphologic units. The advantage of this approach is that it results in a lumped model with a physical basis, with representative parameters that can be derived from point-scale measurable physical parameters. The approach starts with the development of the high-resolution rainfall-runoff model that generates an artificial discharge dataset from rainfall inputs as a surrogate of a real-world dataset. The model is run for approximately 105 scenarios that describe different characteristics of rainfall, properties of the geomorphologic units (i.e. slope gradient, unit length and regolith properties), antecedent moisture conditions and flow patterns. For each scenario-run, the results of the high-resolution model (i.e. runoff and state variables) at selected simulation time steps are stored in a database. The second step is to develop the lumped model of a geomorphological unit. This forward model consists of a set of simple equations that calculate Hortonian runoff and state variables of the geomorphologic unit over time. The lumped model contains only three parameters: a ponding factor, a linear reservoir parameter, and a lag time. The model is capable of giving an appropriate
Directory of Open Access Journals (Sweden)
Paulina Dumnicka
2017-02-01
Full Text Available Acute pancreatitis (AP is an inflammatory disease with varied severity, ranging from mild local inflammation to severe systemic involvement resulting in substantial mortality. Early pathologic events in AP, both local and systemic, are associated with vascular derangements, including endothelial activation and injury, dysregulation of vasomotor tone, increased vascular permeability, increased leukocyte migration to tissues, and activation of coagulation. The purpose of the review was to summarize current evidence regarding the interplay between inflammation, coagulation and endothelial dysfunction in the early phase of AP. Practical aspects were emphasized: (1 we summarized available data on diagnostic usefulness of the markers of endothelial dysfunction and activated coagulation in early prediction of severe AP; (2 we reviewed in detail the results of experimental studies and clinical trials targeting coagulation-inflammation interactions in severe AP. Among laboratory tests, d-dimer and angiopoietin-2 measurements seem the most useful in early prediction of severe AP. Although most clinical trials evaluating anticoagulants in treatment of severe AP did not show benefits, they also did not show significantly increased bleeding risk. Promising results of human trials were published for low molecular weight heparin treatment. Several anticoagulants that proved beneficial in animal experiments are thus worth testing in patients.
Jasper, Micah N; Martin, Sheppard A; Oshiro, Wendy M; Ford, Jermaine; Bushnell, Philip J; El-Masri, Hisham
2016-03-15
People are often exposed to complex mixtures of environmental chemicals such as gasoline, tobacco smoke, water contaminants, or food additives. We developed an approach that applies chemical lumping methods to complex mixtures, in this case gasoline, based on biologically relevant parameters used in physiologically based pharmacokinetic (PBPK) modeling. Inhalation exposures were performed with rats to evaluate the performance of our PBPK model and chemical lumping method. There were 109 chemicals identified and quantified in the vapor in the chamber. The time-course toxicokinetic profiles of 10 target chemicals were also determined from blood samples collected during and following the in vivo experiments. A general PBPK model was used to compare the experimental data to the simulated values of blood concentration for 10 target chemicals with various numbers of lumps, iteratively increasing from 0 to 99. Large reductions in simulation error were gained by incorporating enzymatic chemical interactions, in comparison to simulating the individual chemicals separately. The error was further reduced by lumping the 99 nontarget chemicals. The same biologically based lumping approach can be used to simplify any complex mixture with tens, hundreds, or thousands of constituents.
International Nuclear Information System (INIS)
Ivo, Kljenak; Miroslav, Babic; Borut, Mavko
2007-01-01
The possibility of simulating adequately the flow circulation within a nuclear power plant containment using a lumped-parameter code is considered. An experiment on atmosphere mixing and stratification, which was performed in the containment experimental facility TOSQAN at IRSN (Institute of Radioprotection and Nuclear Safety) in Saclay (France), was simulated with the CFD (Computational Fluid Dynamics) code CFX4 and the lumped-parameter code CONTAIN. During some phases of the experiment, steady states were achieved by keeping the boundary conditions constant. Two steady states during which natural convection was the dominant gas flow mechanism were simulated independently. The nodalization of the lumped-parameter model was based on the flow pattern, simulated with the CFD code. The simulation with the lumped-parameter code predicted basically the same flow circulation patterns within the experimental vessel as the simulation with the CFD code did. (authors)
Coagulant recovery and reuse for drinking water treatment.
Keeley, James; Jarvis, Peter; Smith, Andrea D; Judd, Simon J
2016-01-01
Coagulant recovery and reuse from waterworks sludge has the potential to significantly reduce waste disposal and chemicals usage for water treatment. Drinking water regulations demand purification of recovered coagulant before they can be safely reused, due to the risk of disinfection by-product precursors being recovered from waterworks sludge alongside coagulant metals. While several full-scale separation technologies have proven effective for coagulant purification, none have matched virgin coagulant treatment performance. This study examines the individual and successive separation performance of several novel and existing ferric coagulant recovery purification technologies to attain virgin coagulant purity levels. The new suggested approach of alkali extraction of dissolved organic compounds (DOC) from waterworks sludge prior to acidic solubilisation of ferric coagulants provided the same 14:1 selectivity ratio (874 mg/L Fe vs. 61 mg/L DOC) to the more established size separation using ultrafiltration (1285 mg/L Fe vs. 91 mg/L DOC). Cation exchange Donnan membranes were also examined: while highly selective (2555 mg/L Fe vs. 29 mg/L DOC, 88:1 selectivity), the low pH of the recovered ferric solution impaired subsequent treatment performance. The application of powdered activated carbon (PAC) to ultrafiltration or alkali pre-treated sludge, dosed at 80 mg/mg DOC, reduced recovered ferric DOC contamination to water quality parameters. Several PAC-polished recovered coagulants provided the same or improved DOC and turbidity removal as virgin coagulant, as well as demonstrating the potential to reduce disinfection byproducts and regulated metals to levels comparable to that attained from virgin material. Copyright © 2015 Elsevier Ltd. All rights reserved.
Magnetic Resonance Mediated Radio Frequency Coagulation for Vascular Repair
Zhao, Ming
Purpose. Magnetic Resonance Mediated Radiofrequency Coagulation employs the RF heating effect of MRI scanning to coagulate biomaterials for repair of vascular defects. Coagulation of a protein biomaterial by MR-induced RF heating is a novel means to effect repair of defects such as aneurysms or arteriovenous malformations. Our novel method is to coagulate a thermosetting material (such as egg white, which can be used for investigating heat coagulation behavior and MR relaxation properties) delivered endovascularly by catheter and coagulated by RF-induced heating of an intracatheter resonant wire antenna in the scanner. Methods. Experiments were performed on a Siemens 1.5 T MRI scanner and a Bruker 14T NMR spectrometer. Egg white was brought to equilibrium at seven temperatures (20, 30, 40, 50, 60, 70 and 37 °C) in sequence. Measurement of the water spin-lattice relaxation time Ti, spin-spin relaxation time T2, spin-lattice relaxation time in the rotating frame T1p, or full width at half maximum of the MT spectrum were performed at each temperature. Relaxation parameters of raw egg white and egg white after coagulation at 70 °C were measured in the scanner at 20 °C to determine optimum inversion time, echo time and offset frequency for good image contrast between coagulated and uncoagulated protein. Finally, coagulation of egg white within a glass aneurysm phantom by RF heating in the scanner was performed to demonstrate the MR coagulation methodology and the ability to achieve image contrast between coagulated and uncoagulated biomaterial. Results. Water T2, T1p and MT gave the most definitive indication of the change from uncoagulated at low temperature to fully coagulated at 60 °C, while water T1 showed only the expected gradual increase with temperature, and no response to coagulation. MT weighted imaging is expected to be the optimum method to establish the coagulation condition of the biomaterial.
Hu, Cong-Cong; Tian, Bo; Wu, Xiao-Yu; Yuan, Yu-Qiang; Du, Zhong
2018-02-01
Under investigation is a (3 + 1) -dimensional B-type Kadomtsev-Petviashvili equation, which describes the weakly dispersive waves in a fluid. Via the Hirota method and symbolic computation, we obtain the mixed lump-kink and mixed rogue wave-kink solutions. Through the mixed lump-kink solutions, we observe three different phenomena between a lump and one kink. For the fusion phenomenon, a lump and a kink are merged with the lump's energy transferring into the kink gradually, until the lump merges into the kink completely. Fission phenomenon displays that a lump separates from a kink. The last phenomenon shows that a lump travels together with a kink with their amplitudes unchanged. In addition, we graphically study the interaction between a rogue wave and a pair of the kinks. It can be observed that the rogue wave arises from one kink and disappears into the other kink. At certain time, the amplitude of the rogue wave reaches the maximum.
Coagulation and Mental Disorders
Directory of Open Access Journals (Sweden)
Silvia Hoirisch-Clapauch
2014-10-01
Full Text Available The neurovascular unit is a key player in brain development, homeostasis, and pathology. Mental stress affects coagulation, while severe mental illnesses, such as recurrent depression and schizophrenia, are associated with an increased thrombotic risk and cardiovascular morbidity. Evidence indicates that the hemostatic system is involved to some extent in the pathogenesis, morbidity, and prognosis of a wide variety of psychiatric disorders. The current review focuses on emerging data linking coagulation and some psychiatric disorders.
Optimal Component Lumping: problem formulation and solution techniques
DEFF Research Database (Denmark)
Lin, Bao; Leibovici, Claude F.; Jørgensen, Sten Bay
2008-01-01
This paper presents a systematic method for optimal lumping of a large number of components in order to minimize the loss of information. In principle, a rigorous composition-based model is preferable to describe a system accurately. However, computational intensity and numerical issues restrict ...
Removal of silver nanoparticles by coagulation processes
International Nuclear Information System (INIS)
Sun, Qian; Li, Yan; Tang, Ting; Yuan, Zhihua; Yu, Chang-Ping
2013-01-01
Highlights: • This study investigated the removal of AgNP suspensions by four regular coagulants. • The optimal removal efficiencies for the four coagulants were achieved at pH 7.5. • The removal efficiency of AgNPs was affected by the natural water characteristics. • TEM and XRD showed that AgNPs or silver-containing NPs were adsorbed onto the flocs. -- Abstract: Commercial use of silver nanoparticles (AgNPs) will lead to a potential route for human exposure via potable water. Coagulation followed by sedimentation, as a conventional technique in the drinking water treatment facilities, may become an important barrier to prevent human from AgNP exposures. This study investigated the removal of AgNP suspensions by four regular coagulants. In the aluminum sulfate and ferric chloride coagulation systems, the water parameters slightly affected the AgNP removal. However, in the poly aluminum chloride and polyferric sulfate coagulation systems, the optimal removal efficiencies were achieved at pH 7.5, while higher or lower of pH could reduce the AgNP removal. Besides, the increasing natural organic matter (NOM) would reduce the AgNP removal, while Ca 2+ and suspended solids concentrations would also affect the AgNP removal. In addition, results from the transmission electron microscopy and X-ray diffraction showed AgNPs or silver-containing nanoparticles were adsorbed onto the flocs. Finally, natural water samples were used to validate AgNP removal by coagulation. This study suggests that in the case of release of AgNPs into the source water, the traditional water treatment process, coagulation/sedimentation, can remove AgNPs and minimize the silver ion concentration under the well-optimized conditions
Liu, Yaqing; Wen, Xiaoyong
2018-05-01
In this paper, a generalized (3+1)-dimensional B-type Kadomtsev-Petviashvili (gBKP) equation is investigated by using the Hirota’s bilinear method. With the aid of symbolic computation, some new lump, mixed lump kink and periodic lump solutions are derived. Based on the derived solutions, some novel interaction phenomena like the fission and fusion interactions between one lump soliton and one kink soliton, the fission and fusion interactions between one lump soliton and a pair of kink solitons and the interactions between two periodic lump solitons are discussed graphically. Results might be helpful for understanding the propagation of the shallow water wave.
MILK COAGULATION PROPERTIES OF CATTLE BREEDS REARED IN ALPINE AREA
Directory of Open Access Journals (Sweden)
Giulio Visentin
2015-09-01
Full Text Available The aim of the present study was to apply mid-infrared spectroscopy prediction models developed for milk coagulation properties (MCP to a spectral dataset of 123,240 records collected over a 2-year period in the Alpine area, and to investigate sources of variation of the predicted MCP. Mixed linear models included fixed effects of breed, month and year of sampling, days in milk, parity, and the interactions between the main effects. Random effects were herd nested within breed, cow nested within breed, and the residual. All fixed effects were significant (P<0.05 in explaining the variation of MCP. In particular, milk clotting characteristics varied significantly among breeds, and local Alpine Grey breed exhibited the most favourable processing characteristics. Milk coagulation properties varied across lactation and were at their worst after the peak.
Terenji, Albert; Willmann, Stefan; Osterholz, Jens; Hering, Peter; Schwarzmaier, Hans-Joachim
2005-06-01
During heating, the optical properties of biological tissues change with the coagulation state. In this study, we propose a technique, which uses these changes to monitor the coagulation process during laser-induced interstitial thermotherapy (LITT). Untreated and coagulated (water bath, temperatures between 35 degrees C and 90 degrees C for 20 minutes.) samples of bovine liver tissue were examined using a Nd:YAG (lambda = 1064 nm) frequency-domain reflectance spectrometer. We determined the time integrated intensities (I(DC)) and the phase shifts (Phi) of the photon density waves after migration through the tissue. From these measured quantities, the time of flight (TOF) of the photons and the absorption coefficients of the samples were derived using the modified microscopic Beer-Lambert law. The absorption coefficients of the liver samples decreased significantly with the temperature in the range between 50 degrees C and 70 degrees C. At the same time, the TOF of the investigated photos was found increased indicating an increased scattering. The coagulation dynamics could be well described using the Arrhenius formalism with the activation energy of 106 kJ/mol and the frequency factor of 1.59 x 10(13)/second. Frequency-domain reflectance spectroscopy in combination with the modified microscopic Beer-Lambert (MBL) is suitable to measure heat induced changes in the absorption and scattering properties of bovine liver in vitro. The technique may be used to monitor the coagulation dynamics during local thermo-coagulation in vivo. Copyright 2005 Wiley-Liss, Inc.
Intermittent reservoir daily-inflow prediction using lumped and ...
Indian Academy of Sciences (India)
For the present case study considered, both MLR and ARIMA models performed ... is to be remembered that the transformation of ... Multi-linear regression; lumped and distributed data; time-series models; cause-effect ... flow data are short for adequate system study. ..... that the standard deviation, skewness, kurtosis.
Lumped thermal capacitance analysis of transient heat conduction ...
African Journals Online (AJOL)
Lumped thermal capacitance analysis has been undertaken to investigate the transient temperature variations, associated induced thermal stress distributions, and the structural integrity of Ghana Research Reactor-1 (GHAR R-1) vessel after 15 years of operation. The beltline configuration of the cylindrical vessel of the ...
International Nuclear Information System (INIS)
Lindroos, Alf; Ranta, Heikki; 14C Dating Laboratory, Department of Physics and Astronomy, University of Aarhus (Denmark))" data-affiliation=" (AMS 14C Dating Laboratory, Department of Physics and Astronomy, University of Aarhus (Denmark))" >Heinemeier, Jan; Lill, Jan-Olof
2014-01-01
Mortar dating was applied to newly revealed, original mortar in the church of Dalby in Scania, southern Sweden which is considered to be the oldest still standing church in Scandinavia. Small white lime lumps were sampled by chipping from the supporting pillars in the interior of the church. Special emphasis was in sampling lime lumps because the church is situated in the Scania limestone area and aggregate limestone contamination was anticipated in the bulk mortars. Earlier studies have, however, shown that lime lumps do not contain aggregate material but only possible limestone rests from incomplete calcination. The sampled material was prepared for radiocarbon AMS dating. The carbonate in the lime lumps was hydrolyzed according to the sequential leaching technique developed for the Århus 14 C laboratory in Denmark. Prior to the hydrolysis the lime lumps were examined for dead-carbon contamination using a stereo microscope and cathodoluminescence. The lime lumps displayed heterogeneous carbonate luminescence. This is, however, common and it was not considered a problem because carbonate growth in changing pH/Eh conditions often leads to changing luminescence colors. Two lumps had little dead carbon contamination and an early second millennium 14 C signature. One lump, however, seemed to be heavily contaminated with dead carbon. Since the sample passed the microscopic screening, the leftovers of the lump was subjected to PIXE analysis and compared with the other two lumps. The well-defined, early 2nd millennium 14 C age of the lime lumps of this particular church is an important contribution to the discussion on stone church chronology in Scandinavia
Lumping procedure for a kinetic model of catalytic naphtha reforming
Directory of Open Access Journals (Sweden)
H. M. Arani
2009-12-01
Full Text Available A lumping procedure is developed for obtaining kinetic and thermodynamic parameters of catalytic naphtha reforming. All kinetic and deactivation parameters are estimated from industrial data and thermodynamic parameters are calculated from derived mathematical expressions. The proposed model contains 17 lumps that include the C6 to C8+ hydrocarbon range and 15 reaction pathways. Hougen-Watson Langmuir-Hinshelwood type reaction rate expressions are used for kinetic simulation of catalytic reactions. The kinetic parameters are benchmarked with several sets of plant data and estimated by the SQP optimization method. After calculation of deactivation and kinetic parameters, plant data are compared with model predictions and only minor deviations between experimental and calculated data are generally observed.
Imaging of blood plasma coagulation at supported lipid membranes.
Faxälv, Lars; Hume, Jasmin; Kasemo, Bengt; Svedhem, Sofia
2011-12-15
The blood coagulation system relies on lipid membrane constituents to act as regulators of the coagulation process upon vascular trauma, and in particular the 2D configuration of the lipid membranes is known to efficiently catalyze enzymatic activity of blood coagulation factors. This work demonstrates a new application of a recently developed methodology to study blood coagulation at lipid membrane interfaces with the use of imaging technology. Lipid membranes with varied net charges were formed on silica supports by systematically using different combinations of lipids where neutral phosphocholine (PC) lipids were mixed with phospholipids having either positively charged ethylphosphocholine (EPC), or negatively charged phosphatidylserine (PS) headgroups. Coagulation imaging demonstrated that negatively charged SiO(2) and membrane surfaces exposing PS (obtained from liposomes containing 30% of PS) had coagulation times which were significantly shorter than those for plain PC membranes and EPC exposing membrane surfaces (obtained from liposomes containing 30% of EPC). Coagulation times decreased non-linearly with increasing negative surface charge for lipid membranes. A threshold value for shorter coagulation times was observed below a PS content of ∼6%. We conclude that the lipid membranes on solid support studied with the imaging setup as presented in this study offers a flexible and non-expensive solution for coagulation studies at biological membranes. It will be interesting to extend the present study towards examining coagulation on more complex lipid-based model systems. Copyright © 2011 Elsevier Inc. All rights reserved.
Effect of nano-scale curvature on the intrinsic blood coagulation system
Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.
2014-11-01
The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation.The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation `silent' surface, while nanoparticles with lower surface curvature show denaturation and concomitant coagulation. Electronic supplementary information (ESI) available: Physical properties and scanning electron micrographs (SEM) of silica NPs, intrinsic coagulation activity after 3 h. See DOI: 10.1039/c4nr04128c
Role of cytological grading in the management of breast lump
International Nuclear Information System (INIS)
Mehmood, A.; Ahmed, M.; Jamal, S.
2003-01-01
Objective: To evaluate the fine needle aspiration (FNA) smears of the breast lumps using the cytological evaluation system (C1 to C5) as practiced in the National Breast Screening Programme in the UK. Results: A total of 75 patients of lump breast were included in the project. The age range was 13-75 years with a peak incidence in the 3rd decade. There were 70 (93.3%) females and 5 (6.6%) male cases. Of the total 75 cases, 7 were designated C1, 45 C2, 5 C3, 7 C4 and 11 C5. In surgical biopsies, all the 45 cases designated as C2 proved to be benign with fibroadenoma and fibrocystic change as predominant lesions. All 11 designated C5 proved to be malignant; whereas, of the 5 cases labeled as C3, 4 were benign and one was malignant and out of seven C4 cases, 5 came out as malignant and 2 proved benign. Conclusion: the fine needle aspiration of lump breast has a sensitivity of 94.1%, specificity of 96.0% and accuracy of 95.5%. The C1-C5 grading system is practical, flexible, and gives room for expression of opinion by cytopathologist and easily interpreted by clincians. (author)
Rao, Jiguang; Porsezian, Kuppuswamy; He, Jingsong; Kanna, Thambithurai
2018-01-01
General semi-rational solutions of an integrable multi-component (2+1)-dimensional long-wave-short-wave resonance interaction system comprising multiple short waves and a single long wave are obtained by employing the bilinear method. These solutions describe the interactions between various types of solutions, including line rogue waves, lumps, breathers and dark solitons. We only focus on the dynamical behaviours of the interactions between lumps and dark solitons in this paper. Our detailed study reveals two different types of excitation phenomena: fusion and fission. It is shown that the fundamental (simplest) semi-rational solutions can exhibit fission of a dark soliton into a lump and a dark soliton or fusion of one lump and one dark soliton into a dark soliton. The non-fundamental semi-rational solutions are further classified into three subclasses: higher-order, multi- and mixed-type semi-rational solutions. The higher-order semi-rational solutions show the process of annihilation (production) of two or more lumps into (from) one dark soliton. The multi-semi-rational solutions describe N(N≥2) lumps annihilating into or producing from N-dark solitons. The mixed-type semi-rational solutions are a hybrid of higher-order semi-rational solutions and multi-semi-rational solutions. For the mixed-type semi-rational solutions, we demonstrate an interesting dynamical behaviour that is characterized by partial suppression or creation of lumps from the dark solitons.
Rao, Jiguang; Porsezian, Kuppuswamy; He, Jingsong; Kanna, Thambithurai
2018-01-01
General semi-rational solutions of an integrable multi-component (2+1)-dimensional long-wave-short-wave resonance interaction system comprising multiple short waves and a single long wave are obtained by employing the bilinear method. These solutions describe the interactions between various types of solutions, including line rogue waves, lumps, breathers and dark solitons. We only focus on the dynamical behaviours of the interactions between lumps and dark solitons in this paper. Our detailed study reveals two different types of excitation phenomena: fusion and fission. It is shown that the fundamental (simplest) semi-rational solutions can exhibit fission of a dark soliton into a lump and a dark soliton or fusion of one lump and one dark soliton into a dark soliton. The non-fundamental semi-rational solutions are further classified into three subclasses: higher-order, multi- and mixed-type semi-rational solutions. The higher-order semi-rational solutions show the process of annihilation (production) of two or more lumps into (from) one dark soliton. The multi-semi-rational solutions describe N ( N ≥2) lumps annihilating into or producing from N -dark solitons. The mixed-type semi-rational solutions are a hybrid of higher-order semi-rational solutions and multi-semi-rational solutions. For the mixed-type semi-rational solutions, we demonstrate an interesting dynamical behaviour that is characterized by partial suppression or creation of lumps from the dark solitons.
Tran, Quoc Quan; Willems, Patrick; Pannemans, Bart; Blanckaert, Joris; Pereira, Fernando; Nossent, Jiri; Cauwenberghs, Kris; Vansteenkiste, Thomas
2015-04-01
Based on an international literature review on model structures of existing rainfall-runoff and hydrological models, a generalized model structure is proposed. It consists of different types of meteorological components, storage components, splitting components and routing components. They can be spatially organized in a lumped way, or on a grid, spatially interlinked by source-to-sink or grid-to-grid (cell-to-cell) routing. The grid size of the model can be chosen depending on the application. The user can select/change the spatial resolution depending on the needs and/or the evaluation of the accuracy of the model results, or use different spatial resolutions in parallel for different applications. Major research questions addressed during the study are: How can we assure consistent results of the model at any spatial detail? How can we avoid strong or sudden changes in model parameters and corresponding simulation results, when one moves from one level of spatial detail to another? How can we limit the problem of overparameterization/equifinality when we move from the lumped model to the spatially distributed model? The proposed approach is a step-wise one, where first the lumped conceptual model is calibrated using a systematic, data-based approach, followed by a disaggregation step where the lumped parameters are disaggregated based on spatial catchment characteristics (topography, land use, soil characteristics). In this way, disaggregation can be done down to any spatial scale, and consistently among scales. Only few additional calibration parameters are introduced to scale the absolute spatial differences in model parameters, but keeping the relative differences as obtained from the spatial catchment characteristics. After calibration of the spatial model, the accuracies of the lumped and spatial models were compared for peak, low and cumulative runoff total and sub-flows (at downstream and internal gauging stations). For the distributed models, additional
Dalvand, Arash; Gholibegloo, Elham; Ganjali, Mohammad Reza; Golchinpoor, Najmeh; Khazaei, Mohammad; Kamani, Hossein; Hosseini, Sara Sadat; Mahvi, Amir Hossein
2016-08-01
In this study, the efficiency of Moringa stenopetala seed extract was compared with alum and M. stenopetala-alum hybrid coagulant to remove Direct Red 23 azo dye from textile wastewater. The effects of parameters such as pH, coagulant dose, type of salt used for the extraction of coagulant and initial dye concentration on dye removal efficiency were investigated. Moreover, the existing functional groups on the structure of M. stenopetala coagulant (MSC) were determined by Fourier transform infrared spectroscopy, and the morphology of sludge produced by MSC, alum, and hybrid coagulant was characterized by scanning electron microscopy. Ninhydrin test was also used to determine the quantity of primary amines in the MSC and Moringa oleifera coagulant (MOC). According to the results, with increasing the coagulant dose and decreasing the initial dye concentration, dye removal efficiency has increased. The maximum dye removal of 98.5, 98.2, and 98.3 % were obtained by using 240, 120, and 80 mg/L MSC, alum and hybrid coagulant at pH 7, respectively. The results also showed MSC was much more effective than MOC for dye removal. The volume of sludge produced by MSC was one fourth and half of those produced by alum and hybrid coagulant, respectively. Based on the results, hybrid coagulant was the most efficient coagulant for direct dye removal from colored wastewater.
A lumped parameter model of plasma focus
International Nuclear Information System (INIS)
Gonzalez, Jose H.; Florido, Pablo C.; Bruzzone, H.; Clausse, Alejandro
1999-01-01
A lumped parameter model to estimate neutron emission of a plasma focus (PF) device is developed. The dynamic of the current sheet is calculated using a snowplow model, and the neutron production with the thermal fusion cross section for a deuterium filling gas. The results were contrasted as a function of the filling pressure with experimental measurements of a 3.68 KJ Mather-type PF. (author)
Management of breast lumps in Maiduguri, Nigeria
Directory of Open Access Journals (Sweden)
Ali Nuhu
2014-01-01
Full Text Available Background: Reported changes in the demography, modes of presentation and histological variants of tumors of the breast have been published in developed and some developing countries. Although benign lesions have persistently accounted for most breast tumors, the incidence of malignant breast lesion in young women in sub-Saharan Africa has been disturbingly high. We reviewed the demographics, pattern and management of breast lumps excised at University of Maiduguri Teaching Hospital (UMTH over a 6 year period. Patients and Methods: A retrospective study of patients with breast lumps at UMTH was carried out between January 2005 and December 2010. Details of their bio-data, clinical, and histopathology details were analyzed using descriptive statistics. Results: A total of 913 patients, comprising 887 females (97.2% and 26 males (2.8% were reviewed. The mean age was 33.1 ± 14.6 years (range: 12-80 years and the mean duration of symptoms was 8 ± 2.14 months (range: 2-23 months. 359 (39.3% were malignant and 577 (63.2% were benign. The mean ages of women and men with invasive carcinomas of the breast were 45.58 ± 13.22 and 49.75 ± 18.28 years, respectively. The mean age of women with benign breast disease was 28.4 ± 10.0 for fibrocystic disease and 21.8 ± 5.31 years for fibroadenoma. Mode of presentations included ulcers (8.7%, axillary lymph node enlargement (30.0%, nipple discharge (13.0% and breast pain (21.7%. The most common histological diagnoses were carcinoma of the breast, N = 340 (37.2%, fibroadenoma, N = 276 (30.2% and fibrocystic disease, N = 199 (21.8%. The least common pathology was tuberculosis of the breast, N = 6; (0.7%. Conclusion: Though benign diseases are still more common, a high percentage of breast lumps in Maiduguri are due to malignant disease and this is frequent in younger women.
Polyferric sulphate: preparation, characterisation and application in coagulation experiments.
Zouboulis, A I; Moussas, P A; Vasilakou, F
2008-07-15
The process of coagulation is a core environmental protection technology, which is mainly used in the water or wastewater treatment facilities. Research is now focused on the development of inorganic pre-polymerised coagulants. A characteristic example is PFS (polyferric sulphate), a relatively new pre-polymerised inorganic coagulant with high cationic charge. In this paper, the role of major parameters, including temperature, types of chemical reagents, ratio r=[OH]/[Fe], rate of base addition in the preparation stages of PFS were investigated. Furthermore, the prepared PFS was characterised based on typical properties, such as the percentage of the polymerised iron present in the compound, z-potential, pH, etc. Moreover, dynamics of coagulation process were examined by means of the Photometric Dispersion Analyzer (PDA). Finally, the coagulation efficiency of PFS in treating kaolin suspension and biologically pre-treated wastewater was evaluated in comparison with the respective conventional coagulant agent. The results indicate that certain parameters, such as the r value, the rate of base addition and the duration and temperature of the polymerisation stage, significantly affected the properties of the PFS. Additionally, the prepared PFS polymerised coagulants exhibit a significantly better coagulation performance than the respective non-polymerised one, i.e. ferric sulphate.
29 CFR Appendix C to Part 4022 - Lump Sum Interest Rates for Private-Sector Payments
2010-07-01
... 29 Labor 9 2010-07-01 2010-07-01 false Lump Sum Interest Rates for Private-Sector Payments C Appendix C to Part 4022 Labor Regulations Relating to Labor (Continued) PENSION BENEFIT GUARANTY... Appendix C to Part 4022—Lump Sum Interest Rates for Private-Sector Payments [In using this table: (1) For...
International Nuclear Information System (INIS)
Kljenak, I.; Mavko, B.; Babic, M.
2005-01-01
Full text of publication follows: The modelling and simulation of atmosphere mixing and stratification in nuclear power plant containments is a topic, which is currently being intensely investigated. With the increase of computer power, it has now become possible to model these phenomena with a local instantaneous description, using so-called Computational Fluid Dynamics (CFD) codes. However, calculations with these codes still take relatively long times. An alternative faster approach, which is also being applied, is to model nonhomogeneous atmosphere with lumped-parameter codes by dividing larger control volumes into smaller volumes, in which conditions are modelled as homogeneous. The flow between smaller volumes is modelled using one-dimensional approaches, which includes the prescription of flow loss coefficients. However, some authors have questioned this approach, as it appears that atmosphere stratification may sometimes be well simulated only by adjusting flow loss coefficients to adequate 'artificial' values that are case-dependent. To start the resolution of this issue, a modelling of nonhomogeneous atmosphere with a lumped-parameter code is proposed, where the subdivision of a large volume into smaller volumes is based on results of CFD simulations. The basic idea is to use the results of a CFD simulation to define regions, in which the flow velocities have roughly the same direction. These regions are then modelled as control volumes in a lumped-parameter model. In the proposed work, this procedure was applied to a simulation of an experiment of atmosphere mixing and stratification, which was performed in the TOSQAN facility. The facility is located at the Institut de Radioprotection et de Surete Nucleaire (IRSN) in Saclay (France) and consists of a cylindrical vessel (volume: 7 m3), in which gases are injected. In the experiment, which was also proposed for the OECD/NEA International Standard Problem No.47, air was initially present in the vessel, and
Dennison, James E; Andersen, Melvin E; Yang, Raymond S H
2003-09-01
Gasoline consists of a few toxicologically significant components and a large number of other hydrocarbons in a complex mixture. By using an integrated, physiologically based pharmacokinetic (PBPK) modeling and lumping approach, we have developed a method for characterizing the pharmacokinetics (PKs) of gasoline in rats. The PBPK model tracks selected target components (benzene, toluene, ethylbenzene, o-xylene [BTEX], and n-hexane) and a lumped chemical group representing all nontarget components, with competitive metabolic inhibition between all target compounds and the lumped chemical. PK data was acquired by performing gas uptake PK studies with male F344 rats in a closed chamber. Chamber air samples were analyzed every 10-20 min by gas chromatography/flame ionization detection and all nontarget chemicals were co-integrated. A four-compartment PBPK model with metabolic interactions was constructed using the BTEX, n-hexane, and lumped chemical data. Target chemical kinetic parameters were refined by studies with either the single chemical alone or with all five chemicals together. o-Xylene, at high concentrations, decreased alveolar ventilation, consistent with respiratory irritation. A six-chemical interaction model with the lumped chemical group was used to estimate lumped chemical partitioning and metabolic parameters for a winter blend of gasoline with methyl t-butyl ether and a summer blend without any oxygenate. Computer simulation results from this model matched well with experimental data from single chemical, five-chemical mixture, and the two blends of gasoline. The PBPK model analysis indicated that metabolism of individual components was inhibited up to 27% during the 6-h gas uptake experiments of gasoline exposures.
Wu, Xiao-Yu; Tian, Bo; Chai, Han-Peng; Sun, Yan
2017-08-01
Under investigation in this letter is a (3+1)-dimensional generalized B-type Kadomtsev-Petviashvili equation, which describes the weakly dispersive waves propagating in a fluid. Employing the Hirota method and symbolic computation, we obtain the lump, breather-wave and rogue-wave solutions under certain constraints. We graphically study the lump waves with the influence of the parameters h1, h3 and h5 which are all the real constants: When h1 increases, amplitude of the lump wave increases, and location of the peak moves; when h3 increases, lump wave’s amplitude decreases, but location of the peak keeps unchanged; when h5 changes, lump wave’s peak location moves, but amplitude keeps unchanged. Breather waves and rogue waves are displayed: Rogue waves emerge when the periods of the breather waves go to the infinity.
Approach to the diagnosis of a breast lump
African Journals Online (AJOL)
Generally, the older the woman, the greater the degree of suspicion and the more aggressive the ... When patients present with a history of a breast lump, the first crucial step is to ... A past history of a breast biopsy showing atypical hyperplasia, a family history of ... ultrasonography is the preferred modality for women under ...
Directory of Open Access Journals (Sweden)
Adams Simon T
2009-03-01
Full Text Available Abstract Introduction Silicone lymphadenopathy is a rare but recognised complication of procedures involving the use of silicone. It has a poorly understood mechanism but is thought to occur following the transportation of silicone particles from silicone-containing prostheses to lymph nodes by macrophages. Case presentation We report of a case involving a 35-year-old woman who presented to the breast clinic with a breast lump and altered sensation below her left nipple 5 years after bilateral cosmetic breast augmentations. A small lump was detected inferior to the nipple but clinical examination and initial ultrasound investigation showed both implants to be intact. However, mammography and magnetic resonance imaging of both breasts revealed both intracapsular and extracapsular rupture of the left breast prosthesis. The patient went on to develop a flu-like illness and tender lumps in the left axilla and right mastoid regions. An excision biopsy of the left axillary lesion and replacement of the ruptured implant was performed. Subsequent histological analysis showed that the axillary lump was a lymph node containing large amounts of silicone. Conclusion The exclusion of malignancy remains the priority when dealing with lumps in the breast or axilla. Silicone lymphadenopathy should however be considered as a differential diagnosis in patients in whom silicone prostheses are present.
Energy Technology Data Exchange (ETDEWEB)
Lindroos, Alf, E-mail: alf.lindroos@abo.fi [Geology and Mineralogy, Department of Natural Sciences, Åbo Akademi University (Finland); Art History, Faculty of Art, Åbo Akademi University (Finland); Ranta, Heikki [Diocese of Lund, Church of Sweden (Sweden); Heinemeier, Jan [AMS " 1" 4C Dating Laboratory, Department of Physics and Astronomy, University of Aarhus (Denmark); Lill, Jan-Olof [Accelerator Laboratory, Turku PET Centre, Åbo Akademi University (Finland)
2014-07-15
Mortar dating was applied to newly revealed, original mortar in the church of Dalby in Scania, southern Sweden which is considered to be the oldest still standing church in Scandinavia. Small white lime lumps were sampled by chipping from the supporting pillars in the interior of the church. Special emphasis was in sampling lime lumps because the church is situated in the Scania limestone area and aggregate limestone contamination was anticipated in the bulk mortars. Earlier studies have, however, shown that lime lumps do not contain aggregate material but only possible limestone rests from incomplete calcination. The sampled material was prepared for radiocarbon AMS dating. The carbonate in the lime lumps was hydrolyzed according to the sequential leaching technique developed for the Århus {sup 14}C laboratory in Denmark. Prior to the hydrolysis the lime lumps were examined for dead-carbon contamination using a stereo microscope and cathodoluminescence. The lime lumps displayed heterogeneous carbonate luminescence. This is, however, common and it was not considered a problem because carbonate growth in changing pH/Eh conditions often leads to changing luminescence colors. Two lumps had little dead carbon contamination and an early second millennium {sup 14}C signature. One lump, however, seemed to be heavily contaminated with dead carbon. Since the sample passed the microscopic screening, the leftovers of the lump was subjected to PIXE analysis and compared with the other two lumps. The well-defined, early 2nd millennium {sup 14}C age of the lime lumps of this particular church is an important contribution to the discussion on stone church chronology in Scandinavia.
Coagulation activity in liver disease | Reza | Internet Journal of ...
African Journals Online (AJOL)
Patients with advanced hepatic failure may present with the entire spectrum of coagulation factor deficiencies. This study was designed to determine laboratory abnormalities in coagulation in chronic liver disease and the association of these abnormalities with the extent of chronic hepatitis and cirrhosis. Coagulation ...
Lumped impulses, discrete displacements and a moving load analysis
Kok, A.W.M.
1997-01-01
Finite element models are usually presented as relations between lumped forces and discrete displacements. Mostly finite element models are found by the elaboration of the method of the virtual work - which is a special case of the Galerkin's variational principle -. By application of Galerkin's
Schiavazzi, Daniele E.; Baretta, Alessia; Pennati, Giancarlo; Hsia, Tain-Yen; Marsden, Alison L.
2017-01-01
Summary Computational models of cardiovascular physiology can inform clinical decision-making, providing a physically consistent framework to assess vascular pressures and flow distributions, and aiding in treatment planning. In particular, lumped parameter network (LPN) models that make an analogy to electrical circuits offer a fast and surprisingly realistic method to reproduce the circulatory physiology. The complexity of LPN models can vary significantly to account, for example, for cardiac and valve function, respiration, autoregulation, and time-dependent hemodynamics. More complex models provide insight into detailed physiological mechanisms, but their utility is maximized if one can quickly identify patient specific parameters. The clinical utility of LPN models with many parameters will be greatly enhanced by automated parameter identification, particularly if parameter tuning can match non-invasively obtained clinical data. We present a framework for automated tuning of 0D lumped model parameters to match clinical data. We demonstrate the utility of this framework through application to single ventricle pediatric patients with Norwood physiology. Through a combination of local identifiability, Bayesian estimation and maximum a posteriori simplex optimization, we show the ability to automatically determine physiologically consistent point estimates of the parameters and to quantify uncertainty induced by errors and assumptions in the collected clinical data. We show that multi-level estimation, that is, updating the parameter prior information through sub-model analysis, can lead to a significant reduction in the parameter marginal posterior variance. We first consider virtual patient conditions, with clinical targets generated through model solutions, and second application to a cohort of four single-ventricle patients with Norwood physiology. PMID:27155892
29 CFR 4044.75 - Other lump sum benefits.
2010-07-01
... sum benefits. The value of a lump sum benefit which is not covered under § 4044.73 or § 4044.74 is equal to— (a) The value under the qualifying bid, if an insurer provides the benefit; or (b) The present value of the benefit as of the date of distribution, determined using reasonable actuarial assumptions...
Leaks, Lumps, and Lines: Stigma and Women's Bodies
Chrisler, Joan C.
2011-01-01
Women's bodies have often been positioned in art and popular culture as monstrous or defiled and women's bodily products (e.g., menstrual fluid, breast milk) as disgusting. This framing has led to the stigmatization of aspects of women's bodies (e.g., leaking fluids, lumps of fat, and lines in the skin that indicate aging), especially those…
Energy Technology Data Exchange (ETDEWEB)
Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan [Eberhard Karls University of Tuebingen, Department on Diagnostic and Interventional Radiology, Tuebingen (Germany); Roland, Joerg; Kickhefel, Antje [Siemens Healthcare, Erlangen (Germany); Pereira, Philippe L. [Clinic for radiology, Nuclear Medicine and Minimal Invasive Therapies, SLK-Clinics, Heilbronn (Germany)
2012-05-15
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 {+-} 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)
International Nuclear Information System (INIS)
Rempp, Hansjoerg; Hoffmann, Ruediger; Buck, Alexandra; Claussen, Claus D.; Schick, Fritz; Clasen, Stephan; Roland, Joerg; Kickhefel, Antje; Pereira, Philippe L.
2012-01-01
To evaluate different cut-off temperature levels for a threshold-based prediction of the coagulation zone in magnetic resonance (MR)-guided radiofrequency (RF) ablation of liver tumours. Temperature-sensitive measurements were acquired during RF ablation of 24 patients with primary (6) and secondary liver lesions (18) using a wide-bore 1.5 T MR sytem and compared with the post-interventional coagulation zone. Temperature measurements using the proton resonance frequency shift method were performed directly subsequent to energy application. The temperature maps were registered on the contrast-enhanced follow-up MR images acquired 4 weeks after treatment. Areas with temperatures above 50 , 55 and 60 C were segmented and compared with the coagulation zones. Sensitivity and positive predictive value were calculated. No major complications occurred and all tumours were completely treated. No tumour recurrence was observed at the follow-up examination after 4 weeks. Two patients with secondary liver lesions showed local tumour recurrence after 4 and 7 months. The 60 C threshold level achieved the highest positive predictive value (87.7 ± 9.9) and the best prediction of the coagulation zone. For a threshold-based prediction of the coagulation zone, the 60 C cut-off level achieved the best prediction of the coagulation zone among the tested levels. (orig.)
Comparison of the AWA lumped-circuit model of electrical discharges with empirical data
International Nuclear Information System (INIS)
Maier, W.B. II; Kadish, A.; Robiscoe, R.T.
1990-01-01
The authors compare experimental data for three 1.7-m-long transient discharges with an AWA lumped- circuit discharge model in which the arc resistance is taken from the Arc Welder's Ansatz, R a = V*/|I |, where V* is a positive constant and I is the discharge current. In addition to the arc resistance, there is a small series resistance R present in the external circuit. A single value for each of R and V* is deduced from the data, and these values are used to characterize all three discharges. Adequate agreement with the experimental data is obtained; for example, the authors predict the proper number of current reversals for each discharge and abrupt termination of current flow after a finite time. The authors suggest that the AWA lumped circuit provides a better representation of the data than a standard lumped-circuit RLC model and hence is more useful as a tool for prediction and interpretation of discharges
International Nuclear Information System (INIS)
Alexander G Godizov; Alexander D Efanov; Alexander A Lukianov; Olga V Supotnitskaya
2005-01-01
Full text of publication follows: To describe the phenomena involving aerosol, the model in lumped parameters is used, which is based on the kinetic integral-differential equation for the function of particle distribution of size and content of soluble and insoluble impurities with sources and collision integrals. By the function of particle size distribution, the integral parameters of aerosol can be determined: water content (mass of condensed moisture in a unit of volume), dust content (mass of insoluble condensation nuclei in a unit of volume), calculational concentration and the mean radius of particles. In the aerosol transfer problem being considered, the thermodynamic fields are the external data obtained with a thermal-hydraulic computer code. For numerical simulation of the kinetic equation describing aerosol behavior in coagulation-condensation processes, a hybrid method is used, which combines the method of groups and the method of fractions. To solve the complete equation of aerosol transfer, the method of fractions is used. The integral equation describing aerosol coagulation is solved by means of the group method. The group method based on the representation of particle size distribution in terms of a linear combination of δ-functions with time-dependent arguments makes it possible to calculate the integral parameters of spectrum: the moments of distribution function at a small number of groups. The test calculations were performed by giving the particle spectrum as a lognormal distribution and Γ- function. The hybrid method combined with the thermal-hydraulic computer code enables one to simulate volume condensation of steam at varying thermal-hydraulic conditions. (authors)
Coagulation and Adsorption Treatment of Printing Ink Wastewater
Klančnik, Maja
2014-01-01
The intention of the study was to improve the efficiency of total organic carbon (TOC) and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99...
Importance theory for lumped-parameter systems
International Nuclear Information System (INIS)
Cady, K.B.; Kenton, M.A.; Ward, J.C.; Piepho, M.G.
1981-01-01
A general sensitivity theory has been developed for nonlinear lumped parameter system simulations. The point of departure is general perturbation theory for nonlinear systems. Importance theory as developed here allows the calculation of the sensitivity of a response function to any physical or design parameter; importance of any equation or term or physical effect in the system model on the response function; variance of the response function caused by the variances and covariances of all physical parameters; and approximate effect on the response function of missing physical phenomena or incorrect parameters
Effect of nano-scale curvature on the intrinsic blood coagulation system
Kushida, Takashi; Saha, Krishnendu; Subramani, Chandramouleeswaran; Nandwana, Vikas; Rotello, Vincent M.
2014-01-01
The intrinsic coagulation activity of silica nanoparticles strongly depends on their surface curvature. Nanoparticles with higher surface curvature do not denature blood coagulation factor XII on its surface, providing a coagulation ‘silent’ surface, while nanoparticles with lower surface curvature shows denaturation and concomitant coagulation. PMID:25341004
Use of Lump Parameter Codes at SNSA
International Nuclear Information System (INIS)
Muehleisen, A.
2006-01-01
The lump parameter codes are due to the specifics of Slovenian regulation used only in a very limited scope by the SNSA itself. The law requires that most of the analysis needed for regulatory decision making have to be performed by technical support organisations (TSOs). The use of lump parameter codes is therefore limited to the amount needed to maintain necessary technical competence and to support, to a degree, the reasoning for raising new issues and methodologies. SNSA has available its own NPP MELCOR model and uses for its own purposes NPP Krsko RELAP model. RELAP model is also part of the SNSA NPA analyser. Here presented recent uses at SNSA include use of NPA in support of a project, aimed at estimating maturity and uses of CFD codes for regulatory purposes, transition from MELCOR 1.8.3 to 1.8.5 model and its validation, developing MELCOR PAR model and use of NPA for training purposes. NPA use in support of investigation of CFD usability has been in performing lump parameter code calculation against which the CFD results could be compared. The case of SI injection and the following boron distribution in the reactor vessel has been used for this purpose. The comparison showed that for the particular case there is no urgent need for CFD code calculations, nevertheless the project clearly demonstrated wealth of additional information that can be gained by the use of CFD code. As far as MELCOR model is concerned, only transition of the model to the newer code version has been performed and PAR input prepared and tested. Even though there is a feeling at SNSA that some preliminary analysis with it (such as analysis of typical accidents with PARs present and analysis in support of wet cavity modification) would be useful as a support for decision making as well as for simple training purposes we have not been able to perform them due to other priorities and lack of human resources. SNSA is additionally tasked with support to TSOs in their efforts to maintain and
Some error estimates for the lumped mass finite element method for a parabolic problem
Chatzipantelidis, P.
2012-01-01
We study the spatially semidiscrete lumped mass method for the model homogeneous heat equation with homogeneous Dirichlet boundary conditions. Improving earlier results we show that known optimal order smooth initial data error estimates for the standard Galerkin method carry over to the lumped mass method whereas nonsmooth initial data estimates require special assumptions on the triangulation. We also discuss the application to time discretization by the backward Euler and Crank-Nicolson methods. © 2011 American Mathematical Society.
Treatment of waste water by coagulation and flocculation using biomaterials
Muruganandam, L.; Saravana Kumar, M. P.; Jena, Amarjit; Gulla, Sudiv; Godhwani, Bhagesh
2017-11-01
The present study deals with the determination of physical and chemical parameters in the treatment process of waste water by flocculation and coagulation processes using natural coagulants and assessing their feasibility for water treatment by comparing the performance with each other and with a synthetic coagulant. Initial studies were done on the synthetic waste water to determine the optimal pH and dosage, the activity of natural coagulant, followed by the real effluent from tannery waste. The raw tannery effluent was bluish-black in colour, mildly basic in nature, with high COD 4000mg/l and turbidity in the range 700NTU, was diluted and dosed with organic coagulants, AloeVera, MoringaOleifera and Cactus (O.ficus-indica). The study observed that coagulant Moringa Oleifera of 15 mg/L dose at 6 pH gave the best reduction efficiencies for major physicochemical parameters followed by Aloe Vera and Cactus under identical conditions. The study reveals that the untreated tannery effluents can be treated with environmental confirmative naturally occurring coagulants.
Coagulation chemistries for silica removal from cooling tower water.
Energy Technology Data Exchange (ETDEWEB)
Nyman, May Devan; Altman, Susan Jeanne; Stewart, Tom
2010-02-01
The formation of silica scale is a problem for thermoelectric power generating facilities, and this study investigated the potential for removal of silica by means of chemical coagulation from source water before it is subjected to mineral concentration in cooling towers. In Phase I, a screening of many typical as well as novel coagulants was carried out using concentrated cooling tower water, with and without flocculation aids, at concentrations typical for water purification with limited results. In Phase II, it was decided that treatment of source or make up water was more appropriate, and that higher dosing with coagulants delivered promising results. In fact, the less exotic coagulants proved to be more efficacious for reasons not yet fully determined. Some analysis was made of the molecular nature of the precipitated floc, which may aid in process improvements. In Phase III, more detailed study of process conditions for aluminum chloride coagulation was undertaken. Lime-soda water softening and the precipitation of magnesium hydroxide were shown to be too limited in terms of effectiveness, speed, and energy consumption to be considered further for the present application. In Phase IV, sodium aluminate emerged as an effective coagulant for silica, and the most attractive of those tested to date because of its availability, ease of use, and low requirement for additional chemicals. Some process optimization was performed for coagulant concentration and operational pH. It is concluded that silica coagulation with simple aluminum-based agents is effective, simple, and compatible with other industrial processes.
Directory of Open Access Journals (Sweden)
Leila Mosleh
2014-09-01
Full Text Available Background: The most important process in water treatment plant is coagulation and flocculation. Regular chemical coagulant which used in Iran are aluminum sulfate (Alum and ferric chloride. Chemical coagulants have hazardous effect on human health and their cost is high for developing country. The purpose of this study was to evaluate the comparison of chemical coagulants accompany with corn starch as a coagulant aid, for the turbidity removal from water. Methods: This study was accomplished in pilot-scale with synthetic turbid water using clay. In this research, initial turbidity of 250 and 500 NTU was experimented. Chemical coagulant dose during the experiment was 1, 2 and 5 ppm and natural coagulant dose was 0, 0.1, 0.3, 0.5 and 0.7 ppm. Results: The results showed that maximum removal efficiency of turbidity in initial turbidity of 250 NTU belonged to poly aluminum chloride with 5 ppm dosage and corn starch with 0.7 ppm dosage which removed and reduced the initial turbidity to 98.48% and 3.73 NTU, respectively. Moreover, in initial turbidity of 500 NTU the maximum removal efficiency was 98.52% which belonged to ferric chloride and corn starch (5 and 0.7 ppm respectively and reduced the initial turbidity to 7.4 NTU. Conclusions: The results of this study showed that using natural coagulant aid reduce the chemical coagulant consumption, and also does not have significant effect on pH range and reduce the health risks. While huge amount of required polyelectrolytes for water treatment plant imported to the country and the production of corn starch in our country is high, it is hope that the results of this project can be used in industrial scale.
Aggressive angiomyxoma presenting with huge abdominal lump: A case report
Kumar, Sanjeev; Agrawal, Nikhil; Khanna, Rahul; Khanna, AK
2008-01-01
Agressive angiomyxoma is a rare mesenchymal neoplasm. It mainly presents in females. We here present a case of angiomyxoma presenting as huge abdominal lump along with gluteal swelling. Case note is described along with brief review of literature. PMID:18755035
Coagulation profile in open and video-assisted thoracoscopic lobectomies
DEFF Research Database (Denmark)
Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren
2018-01-01
OBJECTIVES: Lung cancer patients are perceived to have a relatively high risk of venous thromboembolic events due to an activation of the coagulation system. In terms of activation of the coagulation system, the difference between video-assisted thoracoscopic surgery (VATS) and open lobectomies...... for primary lung cancer has not been investigated. The aim of this study was to compare the impact on the coagulation system in patients undergoing curative surgery for primary lung cancer by either VATS or open lobectomies. METHODS: In total, 62 patients diagnosed with primary lung cancer were allocated...... to either VATS (n = 32) or open lobectomies (n = 30). All patients received subcutaneous injections with dalteparin (Fragmin®) 5000 IE once daily. The coagulation was assessed pre- and intraoperatively, and the first 2 days postoperatively by standard coagulation blood tests, thromboelastometry (ROTEM...
van der Poll, T.
2001-01-01
Severe infection induces both activation of the coagulation system and multiple other inflammatory mediator cascades. This concise review summarizes the current knowledge of mechanisms that are considered to contribute to the procoagulant response to sepsis. Furthermore, evidence is discussed that
Solubility of the transport equation in the kinetics of coagulation and fragmentation
International Nuclear Information System (INIS)
Dubovskii, P B
2001-01-01
We prove a local existence theorem for a continuous solution of the spatially inhomogeneous kinetic coagulation-fragmentation model of Smoluchowski. Then we prove the solubility of the problem in the large in the class of continuous functions. It is important to emphasize that we admit unbounded integral kernels in both cases. The uniqueness of the solution and its continuous dependence on the input data are also demonstrated
Incidence data for breast cancer among Yemeni female patients with palpable breast lumps.
Alsanabani, Jamila Ali; Gilan, Waleed; Saadi, Azzan Al
2015-01-01
To estimate the incidence of breast cancer in Yemeni female patients presenting with a breast mass. This retrospective study was carried out with 595 female patients with palpable breast lumps, attending to Alkuwait university hospital, Sana'a, Yemen. Triple assessment, including breast examination, mammography and biopsy (FNAC, core needle, or excision), for all patients were performed. The incidences of benign and malignant lesions was calculated. Some 160 (26.9%) of 595 patients had malignancies; 213 (35.8%) were fibroadenomas; 12 (2.0%) were fibrocystic change; 143 (24.03%) were inflammatory lesions (including mastitis and ductectasia); 62 (10.4%) were simple cysts, while 5 (0.8%) were phyllodes tumors. The mean age of patients with malignant lumps was 44.3 years. Among Yemeni female patients with palpable breast lumps, the rate of breast cancer is high, with occurrence at an earlier age than in Western countries. Improving breast cancer awareness programs and increasing breast cancer screening centers inb different areas of Yemen are needed to establish early diagnosis and offer early and optimal treatment.
Lump Sum Moving Cost and Aggregate Office Space Use
G. Romijn
1997-01-01
textabstractWhen firms decide to change office space use, in many instances this involves relocation. Relocation involves sizable costs to the firm that can to a large extent be characterized as lump sum, i.e. independent of the change in demand. In this paper we propose and solve a model of the
Bio-responsive polymer hydrogels homeostatically regulate blood coagulation.
Maitz, Manfred F; Freudenberg, Uwe; Tsurkan, Mikhail V; Fischer, Marion; Beyrich, Theresa; Werner, Carsten
2013-01-01
Bio-responsive polymer architectures can empower medical therapies by engaging molecular feedback-response mechanisms resembling the homeostatic adaptation of living tissues to varying environmental constraints. Here we show that a blood coagulation-responsive hydrogel system can deliver heparin in amounts triggered by the environmental levels of thrombin, the key enzyme of the coagulation cascade, which--in turn--becomes inactivated due to released heparin. The bio-responsive hydrogel quantitatively quenches blood coagulation over several hours in the presence of pro-coagulant stimuli and during repeated incubation with fresh, non-anticoagulated blood. These features enable the introduced material to provide sustainable, autoregulated anticoagulation, addressing a key challenge of many medical therapies. Beyond that, the explored concept may facilitate the development of materials that allow the effective and controlled application of drugs and biomolecules.
Primary Breast Tuberculosis Presenting as a Lump: A Rare Modern ...
African Journals Online (AJOL)
mammary area. A 25. year.old female, presented with a lump in the breast and infra.mammary area. She was having off and on fever without any other complaints. There was no positive family history. Primary breast tuberculosis was diagnosed on fine ...
Postprandial triglycerides and blood coagulation.
Silveira, A
2001-01-01
Most of our lifetime we spend in the postprandial state. Postprandial triglyceridemia may represent a procoagulant state involving disturbances of both blood coagulation and fibrinolysis, in particular due to elevation of the plasma levels of activated factor VII (VIIa) and plasminogen activator inhibitor (PAI-1). Therefore, disturbances of the hemostatic system might, at least partly, account for by the link between hypertriglyceridemia and coronary heart disease (CHD). Factor VIIa is the first enzyme of the blood coagulation system and serves a priming function for triggering of the clotting cascade. The coagulant activity of factor VII (VIIc, total activity of factor VII in plasma) was identified as an independent predictor of myocardial infarction in initially healthy middle-aged men, and particularly of fatal coronary events, and both serum cholesterol and triglyceride concentrations correlated positively with the VIIc level. Addition of fat to diet has been consistently shown to cause a rapid conversion of the factor VII zymogen into its active form (VIIa) whereas the concentration of total protein is unaffected. Postprandial activation of factor VII is dependent on lipolytic activity and it is mainly supported by large triglyceride-rich lipoprotein of the VLDL class. Studies in vivo with specific coagulation factor-deficient patients indicate that factor IX is essential for the postprandial activation of factor VII. The basal generation of thrombin seems to be unaffected by increased plasma levels of VIIa. However, since VIIa-tissue factor complex is responsible for the initiation of the coagulation cascade, increased generation of VIIa in the postprandial state would increase the potential for thrombin production in the event of plaque rupture. Plasminogen activator inhibitor-1 (PAI-1) is the major physiological inhibitor of the plasminogen activators in the circulation and thereby the principal inhibitor of the fibrinolytic system. Postprandial
Schoots, Ivo G.; Levi, Marcel; van Vliet, Arlène K.; Maas, Adrie M.; Roossink, E. H. Paulina; van Gulik, Thomas M.
2004-01-01
Objective: To examine whether administration of activated protein C or antithrombin reduces local splanchnic derangement of coagulation and inflammation and attenuates intestinal dysfunction and injury following intestinal ischemia/reperfusion. Design: Randomized prospective animal study. Setting:
Directory of Open Access Journals (Sweden)
Nurfarahim Rusdizal
2015-12-01
Full Text Available A study was conducted to treat stabilized leachate by applying polyaluminium chloride (PAC and tobacco leaf extract as a coagulant and coagulant aid. Experimental results indicated that the tobacco leaves were positively charged. The removal rate of the chemical oxygen demand, using 1500 mg/L PAC as a sole coagulant, was approximately 63% and increased to 91% when 1000 mg/L PAC was mixed with 1000 mg/L tobacco leaf. Additionally, 1500 mg/L PAC with 250 - 1000 mg/L tobacco leaf and 54% ammoniacal nitrogen was removed, compared with only 46% reduction using 1500 mg/L with only 46% reduction.
Implementation of a microcontroller-based semi-automatic coagulator.
Chan, K; Kirumira, A; Elkateeb, A
2001-01-01
The coagulator is an instrument used in hospitals to detect clot formation as a function of time. Generally, these coagulators are very expensive and therefore not affordable by a doctors' office and small clinics. The objective of this project is to design and implement a low cost semi-automatic coagulator (SAC) prototype. The SAC is capable of assaying up to 12 samples and can perform the following tests: prothrombin time (PT), activated partial thromboplastin time (APTT), and PT/APTT combination. The prototype has been tested successfully.
Do Lumped-Parameter Models Provide the Correct Geometrical Damping?
DEFF Research Database (Denmark)
Andersen, Lars
response during excitation and the geometrical damping related to free vibrations of a hexagonal footing. The optimal order of a lumped-parameter model is determined for each degree of freedom, i.e. horizontal and vertical translation as well as torsion and rocking. In particular, the necessity of coupling...... between horizontal sliding and rocking is discussed....
Start-up of belt conveyors used for haulage of large lumps under difficult climatic conditions
Energy Technology Data Exchange (ETDEWEB)
Drobny, J
1979-01-01
Investigations are discussed carried out by the Research and Development Center for Brown Coal in Most, Czechoslovakia into effects of climate, weather and mass of coal lumps on reliability of belt conveyors in surface mines. Dirt buildup on the driving drums reduces friction and increases belt sliding hazards. Belt wear increases. Driving drum diameter, increased by the buildup, negatively influences load distribution among the electric motors of the drive system. In extreme cases belt wear and irregular load distribution cause belt failures. Methods for buildup removal used in Czechoslovakia and methods for protection of the return side of a conveyor are described. Effects of large mass of coal lumps and ice buildup on large lumps on the risk of belt damage (cuts, punctures etc,) are discussed. Recommendations for design of coal transfer points are made. 2 refs.
Cong, Zhang
2018-03-01
Based on extended state observer, a novel and practical design method is developed to solve the distributed cooperative tracking problem of higher-order nonlinear multiagent systems with lumped disturbance in a fixed communication topology directed graph. The proposed method is designed to guarantee all the follower nodes ultimately and uniformly converge to the leader node with bounded residual errors. The leader node, modeled as a higher-order non-autonomous nonlinear system, acts as a command generator giving commands only to a small portion of the networked follower nodes. Extended state observer is used to estimate the local states and lumped disturbance of each follower node. Moreover, each distributed controller can work independently only requiring the relative states and/or the estimated relative states information between itself and its neighbors. Finally an engineering application of multi flight simulators systems is demonstrated to test and verify the effectiveness of the proposed algorithm. Copyright © 2018 ISA. Published by Elsevier Ltd. All rights reserved.
20 CFR 725.521 - Commutation of payments; lump sum awards.
2010-04-01
... present value of future benefit payments commuted, computed at 4 percent true discount compounded annually... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Commutation of payments; lump sum awards. 725.521 Section 725.521 Employees' Benefits EMPLOYMENT STANDARDS ADMINISTRATION, DEPARTMENT OF LABOR...
Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds.
Okuda, T; Baes, A U; Nishijima, W; Okada, M
2001-03-01
This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC tap water formed insoluble matters. This formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each molecule of the active coagulation component in MOC-SC-PC and form a net-like structure. The coagulation mechanism of MOC-SC-PC seemed to be an enmeshment of Kaolin by the insoluble matters with the net-like structure. In case of Ca2+ ion (bivalent cations), at least 0.2 mM was necessary for coagulation at 0.3 mgC l-1 dose of MOC-SC-PC. Other coagulation mechanisms like compression of double layer, interparticle bridging or charge neutralization were not responsible for the coagulation by MOC-SC-PC.
National Research Council Canada - National Science Library
Barry, Robert
2001-01-01
... the impact of personal characteristics, civilian pay, unemployment, and the lump sum bonus on reenlistment decisions, Marine retention probabilities under the lump sum payment program are compared...
Infrared coagulation: a new treatment for hemorrhoids
International Nuclear Information System (INIS)
Leicester, R.J.; Nicholls, R.J.; Mann, C.V.
1981-01-01
Many methods, which have effectively reduced the number of patients requiring hospital admission, have been described for the outpatient treatment of hemorrhoids. However, complications have been reported, and the methods are often associated with unpleasant side effects. In 1977 Neiger et al. described a new method that used infrared coagulation, which produced minimal side effects. The authors have conducted a prospective, randomized trial to evaluate infrared coagulation compared with more traditional methods of treatment. The authors' results show that it may be more effective than injection sclerotherapy in treating non-prolapsing hemorrhoids and that it compares favorably with rubber band ligation in most prolapsing hemorrhoids. No complications occurred, and significantly fewer patients experienced pain after infrared coagulation
Intraventricular hemorrhage in preterm infants: coagulation perspectives.
Kuperman, Amir A; Kenet, Gili; Papadakis, Emmanuel; Brenner, Benjamin
2011-10-01
It has long been considered that a severe coagulation deficiency in premature newborns could be a major contributing factor in the occurrence of intraventricular hemorrhage (IVH). High-grade IVH has also been shown to coincide with severe derangement of coagulation in extremely low birth weight infants. This review focuses on the relevance of the physiologically developing immature hemostatic system to IVH, and the potential benefit of agents affecting hemostasis for IVH therapy or prevention in preterm infants. The findings of small, open-label interventional studies on the effect of ethamsylate, vitamin K, fresh frozen plasma, recombinant activated factor VII, and prothrombin complex concentrate on the premature coagulation system will be reviewed. © Thieme Medical Publishers.
Directory of Open Access Journals (Sweden)
Nowacka Anna
2014-12-01
Full Text Available The article presents results on investigation of the removal efficiency of selected 5- and 6-ring polycyclic aromatic hydrocarbons (benzo[a]pyrene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[j]fluoranthene, benzo[g,h,i]perylene, indeno[1,2,3-cd]pyrene, dibenzo[a,h]anthracene from water during coagulation and sedimentation process. Two pre-hydrolyzed aluminum coagulants: PAX XL 19H and FLOKOR 105V were chosen for research. Process was carried out at optimum process parameters: rapid-mixing - 3 min at the rotational speed of 200 rpm, slow mixing - 10 min at 30 rpm, sedimentation - 60 min. The removal effectiveness was dependant on coagulant type and its composition. Better results in the removal of 5-and 6-ring PAHs were obtained after application of FLOKOR 105V (lower aluminum content than after using PAX XL 19H.
WATGIS: A GIS-Based Lumped Parameter Water Quality Model
Glenn P. Fernandez; George M. Chescheir; R. Wayne Skaggs; Devendra M. Amatya
2002-01-01
A Geographic Information System (GIS)Âbased, lumped parameter water quality model was developed to estimate the spatial and temporal nitrogenÂloading patterns for lower coastal plain watersheds in eastern North Carolina. The model uses a spatially distributed delivery ratio (DR) parameter to account for nitrogen retention or loss along a drainage network. Delivery...
International Nuclear Information System (INIS)
Ozdemir, Ozkan Emre; George, Thomas L.
2015-01-01
As a part of the GOTHIC (GOTHIC incorporates technology developed for the electric power industry under the sponsorship of EPRI.) Fukushima Technical Evaluation project (EPRI, 2014a, b, 2015), GOTHIC (EPRI, 2014c) has been benchmarked against test data for pool stratification (EPRI, 2014a, b, Ozdemir and George, 2013). These tests confirmed GOTHIC’s ability to simulate pool mixing and stratification under a variety of anticipated suppression pool operating conditions. The multidimensional modeling requires long simulation times for events that may occur over a period of hours or days. For these scenarios a lumped model of the pressure suppression chamber is desirable to maintain reasonable simulation times. However, a lumped model for the pool is not able to predict the effects of pool stratification that can influence the overall containment response. The main objective of this work is on the development of a correlation that can be used to estimate pool mixing and stratification effects in a lumped modeling approach. A simplified lumped GOTHIC model that includes a two zone model for the suppression pool with controlled circulation between the upper and lower zones was constructed. A pump and associated flow connections are included to provide mixing between the upper and lower pool volumes. Using numerically generated data from a multidimensional GOTHIC model for the suppression pool, a correlation was developed for the mixing rate between the upper and lower pool volumes in a two-zone, lumped model. The mixing rate depends on the pool subcooling, the steam injection rate and the injection depth
Optimum coagulant forecasting by modeling jar test experiments using ANNs
Haghiri, Sadaf; Daghighi, Amin; Moharramzadeh, Sina
2018-01-01
Currently, the proper utilization of water treatment plants and optimizing their use is of particular importance. Coagulation and flocculation in water treatment are the common ways through which the use of coagulants leads to instability of particles and the formation of larger and heavier particles, resulting in improvement of sedimentation and filtration processes. Determination of the optimum dose of such a coagulant is of particular significance. A high dose, in addition to adding costs, can cause the sediment to remain in the filtrate, a dangerous condition according to the standards, while a sub-adequate dose of coagulants can result in the reducing the required quality and acceptable performance of the coagulation process. Although jar tests are used for testing coagulants, such experiments face many constraints with respect to evaluating the results produced by sudden changes in input water because of their significant costs, long time requirements, and complex relationships among the many factors (turbidity, temperature, pH, alkalinity, etc.) that can influence the efficiency of coagulant and test results. Modeling can be used to overcome these limitations; in this research study, an artificial neural network (ANN) multi-layer perceptron (MLP) with one hidden layer has been used for modeling the jar test to determine the dosage level of used coagulant in water treatment processes. The data contained in this research have been obtained from the drinking water treatment plant located in Ardabil province in Iran. To evaluate the performance of the model, the mean squared error (MSE) and correlation coefficient (R2) parameters have been used. The obtained values are within an acceptable range that demonstrates the high accuracy of the models with respect to the estimation of water-quality characteristics and the optimal dosages of coagulants; so using these models will allow operators to not only reduce costs and time taken to perform experimental jar tests
A lumped-parameter model for cryo-adsorber hydrogen storage tank
Energy Technology Data Exchange (ETDEWEB)
Senthil Kumar, V.; Raghunathan, K. [India Science Lab, General Motors R and D, Creator Building, International Technology Park, Bangalore 560066 (India); Kumar, Sudarshan [Chemical and Environmental Sciences Lab, General Motors R and D, 30500 Mound Road, Warren, MI 48090 (United States)
2009-07-15
One of the primary requirements for commercialization of hydrogen fuel-cell vehicles is the on-board storage of hydrogen in sufficient quantities. On-board storage of hydrogen by adsorption on nano-porous adsorbents at around liquid nitrogen temperatures and moderate pressures is considered viable and competitive with other storage technologies: liquid hydrogen, compressed gas, and metallic or complex hydrides. The four cryo-adsorber fuel tank processes occur over different time scales: refueling over a few minutes, discharge over a few hours, dormancy over a few days, and venting over a few weeks. The slower processes i.e. discharge, dormancy and venting are expected to have negligible temperature gradients within the bed, and hence are amenable to a lumped-parameter analysis. Here we report a quasi-static lumped-parameter model for the cryo-adsorber fuel tank, and discuss the results for these slower processes. We also describe an alternative solution method for dormancy and venting based on the thermodynamic state description. (author)
Disseminated intravascular coagulation in meningococcal sepsis. Case 7
Zeerleder, S.; Zürcher Zenklusen, R.; Hack, C. E.; Wuillemin, W. A.
2003-01-01
We report on a man (age: 49 years), who died from severe meningococcal sepsis with disseminated intravascular coagulation (DIC), multiple organ dysfunction syndrome and extended skin necrosis. We discuss in detail the pathophysiology of the activation of coagulation and fibrinolysis during sepsis.
Interplay between coagulation and vascular inflammation in sickle cell disease
Sparkenbaugh, Erica; Pawlinski, Rafal
2013-01-01
Sickle cell disease is the most common inherited hematologic disorder that leads to the irreversible damage of multiple organs. Although sickling of red blood cells and vaso-occlusion are central to the pathophysiology of sickle cell disease the importance of hemolytic anemia and vasculopathy has been recently recognized. Hypercoagulation state is another prominent feature of sickle cell disease and is mediated by activation of both intrinsic and extrinsic coagulation pathways. Growing evidence demonstrates that coagulation may not only contribute to the thrombotic complications, but also to vascular inflammation associated with this disease. This article summarizes the role of vascular inflammation and coagulation activation, discusses potential mechanisms responsible for activation of coagulation and reviews recent data demonstrating the crosstalk between coagulation and vascular inflammation in sickle cell disease. PMID:23593937
Colloids removal from water resources using natural coagulant: Acacia auriculiformis
Abdullah, M.; Roslan, A.; Kamarulzaman, M. F. H.; Erat, M. M.
2017-09-01
All waters, especially surface waters contain dissolved, suspended particles and/or inorganic matter, as well as several biological organisms, such as bacteria, algae or viruses. This material must be removed because it can affect the water quality that can cause turbidity and colour. The objective of this study is to develop water treatment process from Seri Alam (Johor, Malaysia) lake water resources by using natural coagulant Acacia auriculiformis pods through a jar test experiment. Jar test is designed to show the effectiveness of the water treatment. This process is a laboratory procedure that will simulate coagulation/flocculation with several parameters selected namely contact time, coagulant dosage and agitation speed. The most optimum percentage of colloids removal for each parameter is determined at 0.2 g, 90 min and 80 rpm. FESEM (Field-emission Scanning Electron Microscope) observed the small structures of final floc particles for optimum parameter in this study to show that the colloids coagulated the coagulant. All result showed that the Acacia auriculiformis pods can be a very efficient coagulant in removing colloids from water.
Tissue Factor Coagulant Activity is Regulated by the Plasma Membrane Microenvironment.
Yu, Yuanjie; Böing, Anita N; Hau, Chi M; Hajji, Najat; Ruf, Wolfram; Sturk, Auguste; Nieuwland, Rienk
2018-06-01
Tissue factor (TF) can be present in a non-coagulant and coagulant form. Whether the coagulant activity is affected by the plasma membrane microenvironment is unexplored. This article studies the presence and coagulant activity of human TF in plasma membrane micro-domains. Plasma membranes were isolated from human MIA PaCa2 cells, MDA-MB-231 cells and human vascular smooth muscle cells by Percoll gradient ultracentrifugation after cell disruption. Plasma membranes were fractionated by OptiPrep gradient ultracentrifugation, and the presence of TF, flotillin, caveolin, clathrin, protein disulphide isomerase (PDI), TF pathway inhibitor (TFPI) and phosphatidylserine (PS) were determined. Plasma membranes contain two detergent-resistant membrane (DRM) compartments differing in density and biochemical composition. High-density DRMs (DRM-H) have a density ( ρ ) of 1.15 to 1.20 g/mL and contain clathrin, whereas low-density DRMs (DRM-L) have a density between 1.09 and 1.13 g/mL and do not contain clathrin. Both DRMs contain TF, flotillin and caveolin. PDI is detectable in DRM-H, TFPI is not detectable in either DMR-H or DRM-L and PS is detectable in DRM-L. The DRM-H-associated TF (> 95% of the TF antigen) lacks detectable coagulant activity, whereas the DRM-L-associated TF triggers coagulation. This coagulant activity is inhibited by lactadherin and thus PS-dependent, but seemed insensitive to 16F16, an inhibitor of PDI. Non-coagulant and coagulant TF are present within different types of DRMs in the plasma membrane, and the composition of these DRMs may affect the TF coagulant activity. Schattauer GmbH Stuttgart.
The liquid lift: Looking natural without lumps
Directory of Open Access Journals (Sweden)
Iñigo de Felipe
2015-01-01
Full Text Available Context: Hyaluronic acid (HA is the most common filler used to rejuvenate. Today, a three-dimensional approach prevails over previous techniques in which this material was used in specific areas of the face such as the nasolabial fold, the marionette line, and the eye trough giving a strange appearance that does not look natural. Even with a volumizing purpose, the injection of HA can sometimes produce clinically detectable nodules or lumps where the filler is deposited. Aims: To develop a new technique of injecting HA that can provide more natural results and avoid the lumpiness and nodular appearance that sometimes occurs with the injection of HA. To detect whether mixing HA with diluted anesthetic agent modifies its behavior. Settings and Design: Prospective, case control, single-center study on a private clinic setting. Materials and Methods: Eighty six patients were enrolled in this study. All of them had a previous treatment with nondiluted HA using a needle at least a year before. Patients were injected with 8 mL of reticulated HA (RHA mixed with 6 mL of saline and 2 mL of anesthetic agent. The mixture was administered through a cannula inserted in the face, one at mid-cheek and another at frontal-temporal point of entry. Owing to the lifting effect of this mixture we called this procedure liquid lift (LL. Patients were evaluated 1 month, 6 months, and a year later and asked to compare the LL with previous experiences in terms of natural look, pain, and appearance of nodules. Statistical Analysis Used: Student′s t-test. Results: One month after the treatment, 83 out of 86 patients (96.5% thought LL produced a more natural look than the previous treatment with the needle. Sixty two (72% considered LL less painful than the previous treatment and only eight (9.3% could detect lumps or nodules 1 month after LL was performed compared with 46 (53.5% that described this problem with previous needle injections. The incidence of bruising was
A Calibrated Lumped Element Model for the Prediction of PSJ Actuator Efficiency Performance
Directory of Open Access Journals (Sweden)
Matteo Chiatto
2018-03-01
Full Text Available Among the various active flow control techniques, Plasma Synthetic Jet (PSJ actuators, or Sparkjets, represent a very promising technology, especially because of their high velocities and short response times. A practical tool, employed for design and manufacturing purposes, consists of the definition of a low-order model, lumped element model (LEM, which is able to predict the dynamic response of the actuator in a relatively quick way and with reasonable fidelity and accuracy. After a brief description of an innovative lumped model, this work faces the experimental investigation of a home-designed and manufactured PSJ actuator, for different frequencies and energy discharges. Particular attention has been taken in the power supply system design. A specific home-made Pitot tube has allowed the detection of velocity profiles along the jet radial direction, for various energy discharges, as well as the tuning of the lumped model with experimental data, where the total device efficiency has been assumed as a fitting parameter. The best fitting value not only contains information on the actual device efficiency, but includes some modeling and experimental uncertainties, related also to the used measurement technique.
Directory of Open Access Journals (Sweden)
Rubanick JV
2017-02-01
Full Text Available Jean V Rubanick, Medora B Pashmakova, Micah A Bishop, James W Barr Department of Veterinary Small Animal Clinical Sciences, Texas A&M University, College Station, TX, USA Abstract: A hospital-based, prospective cross-sectional study was used to compare kaolin-activated thromboelastography (TEG parameters with traditional coagulation tests in 29 hospitalized dogs. Cases were included if the attending clinician requested coagulation testing. Blood was obtained from each dog and coagulation (prothrombin time, partial thromboplastin time, antithrombin activity, d-dimer concentration, and fibrinogen concentration and TEG analyses were performed. Hematocrit (Hct was also measured. Traditional coagulation results were evaluated for correlation with those from kaolin-activated TEG. Spearman’s correlation was used to calculate correlation coefficients. Fibrinogen was positively correlated with maximum amplitude (Pearson r=0.72, P<0.001 and global clot strength (Pearson r=0.72, P<0.001. There was no correlation between any of the remaining coagulation variables, TEG parameters, or Hct. Results of kaolin-activated TEG and traditional coagulation tests are not interchangeable means of monitoring coagulation derangements in this intensive care unit patient population. Determination of a true outcome measure is necessary to establish TEG’s clinical relevance to veterinary medicine. Keywords: TEG, thromboelastography, coagulation, hemostasis
Chen, Wei; Zheng, Huaili; Teng, Houkai; Wang, Yili; Zhang, Yuxin; Zhao, Chuanliang; Liao, Yong
2015-01-01
PO4(3-) and SiO3(2-) are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants--polyferric phosphoric sulfate (PFPS), polysilicon ferric sulfate (PFSS), and polyferric sulfate (PFS) were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR) spectroscopy, X-ray diffraction (XRD) and Scanning electron microscope (SEM). Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4(3-) and SiO3(2-). Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond.
Directory of Open Access Journals (Sweden)
Wei Chen
Full Text Available PO4(3- and SiO3(2- are often used as modifier to improve stability and aggregating ability of the iron-base coagulants, however, there are few reports about their detailed comparison between the coagulation performance and mechanisms. In this study, three coagulants--polyferric phosphoric sulfate (PFPS, polysilicon ferric sulfate (PFSS, and polyferric sulfate (PFS were synthesized; their structure and morphology were characterized by Fourier transformed infrared (FT-IR spectroscopy, X-ray diffraction (XRD and Scanning electron microscope (SEM. Alkali titration and Ferron species analysis were employed to investigate the hydrolysis performance and species distribution. Jar test was conducted to measure their coagulation behaviors at different dosage, pH, and temperatures in which the flocs properties were measured. The results showed that a number of new compounds were formed due to the presence of PO4(3- and SiO3(2-. Moreover, PFPS and PFSS had similar level in Fea as well as Feb. Among them, PFPS produced more multi-core iron atoms polymer and content of Feb, and the formed flocs were larger and denser. It exhibited superior coagulation performance in terms of turbidity reduction, UV254 removal and residual ferric concentration. Jar test and floc breakage/regrowth experiments indicated other than charge neutrality, the dominated mechanism involved in PFSS was the adsorption between polysilicic acid and solution particle, while PFPS was sweeping, entrapment/adsorption resulting from larger polymer colloid of Fe-P chemistry bond.
International Nuclear Information System (INIS)
Oezyurt, N.N.
2002-01-01
Groundwater's residence time distribution is an important information to identify the transport mechanism in aquifer systems. In the absence or scarcity of geometric, hydraulic and geohydrologic data needed to describe a flow system, lumped parameter models, that handle the flow system as a whole, exist as an alternative to determine the residence time distribution. Lumped parametre models comprise of idealized models of piston and well-mixed flow and their combinations. Aquifer properties such as, dead volume and by-pass flow can also be included in these models. With the aid of these models, conceptual aquifer models can be tested and residence time distribution of groundwater can be determined
Coagulation profile in patients undergoing video-assisted thoracoscopic lobectomy
DEFF Research Database (Denmark)
Christensen, Thomas Decker; Vad, Henrik; Pedersen, Søren
2017-01-01
-, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM®) and thrombin generation. Results: Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority......Background: Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH) on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video......-Assisted Thoracoscopic Surgery (VATS) lobectomy for primary lung cancer. Methods: Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin®) 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri...
Characterization of coagulation factor synthesis in nine human primary cell types
Dashty, Monireh; Akbarkhanzadeh, Vishtaseb; Zeebregts, Clark J.; Spek, C. Arnold; Sijbrands, Eric J.; Peppelenbosch, Maikel P.; Rezaee, Farhad
2012-01-01
The coagulation/fibrinolysis system is essential for wound healing after vascular injury. According to the standard paradigm, the synthesis of most coagulation factors is restricted to liver, platelets and endothelium. We challenged this interpretation by measuring coagulation factors in nine human
Lumped elements for RF and microwave circuits
Bahl, Inder
2003-01-01
Due to the unprecedented growth in wireless applications over the past decade, development of low-cost solutions for RF and microwave communication systems has become of great importance. This practical new book is the first comprehensive treatment of lumped elements, which are playing a critical role in the development of the circuits that make these cost-effective systems possible. The books offers you an in-depth understanding of the different types of RF and microwave circuit elements, including inductors, capacitors, resistors, transformers, via holes, airbridges, and crossovers. Support
Treatment of sugar beet thick juice spent wash by chemical and natural coagulants
Directory of Open Access Journals (Sweden)
Antov Mirjana G.
2009-01-01
Full Text Available The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH 6.5 is reached with a dose of 0.5 ml/l. However, when common bean natural coagulant was used simultaneously with alum, the highest turbidity removal resulting in 24% coagulation activity was achieved and this was more efficient than when alum or natural coagulant were used.
Isolated macrodactyly or extremely localized Proteus syndrome?
van Bever, Y.; Hennekam, R. C.
1994-01-01
We report on a woman with unilateral macrosyndactyly of the second and third toes, a local plantar soft tissue lump, and radiographically an abnormal shape of the phalanges of the affected toes. This finding may represent either an isolated macrosyndactyly or an extremely localised form of Proteus
Coagulation management in patients undergoing neurosurgical procedures.
Robba, Chiara; Bertuetti, Rita; Rasulo, Frank; Bertuccio, Alessando; Matta, Basil
2017-10-01
Management of coagulation in neurosurgical procedures is challenging. In this contest, it is imperative to avoid further intracranial bleeding. Perioperative bleeding can be associated with a number of factors, including anticoagulant drugs and coagulation status but is also linked to the characteristic and the site of the intracranial disorder. The aim of this review will be to focus primarily on the new evidence regarding the management of coagulation in patients undergoing craniotomy for neurosurgical procedures. Antihemostatic and anticoagulant drugs have shown to be associated with perioperative bleeding. On the other hand, an increased risk of venous thromboembolism and hypercoagulative state after elective and emergency neurosurgery, in particular after brain tumor surgery, has been described in several patients. To balance the risk between thrombosis and bleeding, it is important to be familiar with the perioperative changes in coagulation and with the recent management guidelines for anticoagulated patients undergoing neurosurgical procedures, in particular for those taking new direct anticoagulants. We have considered the current clinical trials and literature regarding both safety and efficacy of deep venous thrombosis prophylaxis in the neurosurgical population. These were mainly trials concerning both elective surgical and intensive care patients with a poor grade intracranial bleed or multiple traumas with an associated severe traumatic brain injury (TBI). Coagulation management remains a major issue in patients undergoing neurosurgical procedures. However, in this field of research, literature quality is poor and further studies are necessary to identify the best strategies to minimize risks in this group of patients.
A new lumped-parameter approach to simulating flow processes in unsaturated dual-porosity media
Energy Technology Data Exchange (ETDEWEB)
Zimmerman, R.W.; Hadgu, T.; Bodvarsson, G.S. [Lawrence Berkeley Laboratory, CA (United States)
1995-03-01
We have developed a new lumped-parameter dual-porosity approach to simulating unsaturated flow processes in fractured rocks. Fluid flow between the fracture network and the matrix blocks is described by a nonlinear equation that relates the imbibition rate to the local difference in liquid-phase pressure between the fractures and the matrix blocks. This equation is a generalization of the Warren-Root equation, but unlike the Warren-Root equation, is accurate in both the early and late time regimes. The fracture/matrix interflow equation has been incorporated into a computational module, compatible with the TOUGH simulator, to serve as a source/sink term for fracture elements. The new approach achieves accuracy comparable to simulations in which the matrix blocks are discretized, but typically requires an order of magnitude less computational time.
Coagulation defects in experimental hepatic injury in the dog.
Osbaldiston, G W; Hoffman, M W
1971-04-01
Alteration in activity of blood coagulation factors in dogs with acute hepatic injury caused by oral carbon tetrachloride dosing was studied. Coagulation Factors II, VII and IX were dramatically reduced within 48 hours but recovered to normal in the next five days. Because surgery is rarely performed on dogs with hepatic necrosis, the use of fresh whole blood tranfusion to improve the coagulation defect in hepatic injury was also studied. Transfusion was found to have only a temporary beneficial effect.
Improved lumped parameter for annular fuel element thermohydraulic analysis
International Nuclear Information System (INIS)
Duarte, Juliana Pacheco; Su, Jian; Alvim, Antonio Carlos Marques
2011-01-01
Annular fuel elements have been intensively studied for the purpose of increasing power density in light water reactors (LWR). This paper presents an improved lumped parameter model for the dynamics of a LWR core with annular fuel elements, composed of three sub-models: the fuel dynamics model, the neutronics model, and the coolant energy balance model. The transient heat conduction in radial direction is analyzed through an improved lumped parameter formulation. The Hermite approximation for integration is used to obtain the average temperature of the fuel and cladding and also to obtain the average heat flux. The volumetric heat generation in fuel rods was obtained with the point kinetics equations with six delayed neutron groups. The equations for average temperature of fuel and cladding are solved along with the point kinetic equations, assuming linear reactivity and coolant temperature in cases of reactivity insertion. The analytical development of the model and the numeric solution of the ordinary differential equation system were obtained by using Mathematica 7.0. The dynamic behaviors for average temperatures of fuel, cladding and coolant in transient events as well as the reactor power were analyzed. (author)
Treatment of phosphate-containing oily wastewater by coagulation and microfiltration.
Zhang, Jin; Sun, Yu-xin; Huang, Zhi-feng; Liu, Xing-qin; Meng, Guang-yao
2006-01-01
The oily wastewater generated from pretreatment unit of electrocoating industry contains oils, phosphate, organic solvents, and surfactants. In order to improve the removal efficiencies of phosphate and oils, to mitigate the membrane fouling, coagulation for ceramic membrane microfiltration of oily wastewater was performed. The results of filtration tests show that the membrane fouling decreased and the permeate flux and quality increased with coagulation as pretreatment. At the coagulant Ca (OH)2 dosage of 900 mg/L, the removal efficiency of phosphate was increased from 46.4% without coagulation to 99.6%; the removal of COD and oils were 97.0% and 99.8%, respectively. And the permeate flux was about 70% greater than that when Ca(OH)2 was not used. The permeate obtained from coagulation and microfiltration can be reused as make-up water, and the recommended operation conditions for pilot and industrial application are transmembrane pressure of 0.10 MPa and cross-flow velocity of 5 m/s. The comparison results show that 0.2 microm ZrO2 microfilter with coagulation could be used to perform the filtration rather than conventional ultrafilter, with very substantial gain in flux and removal efficiency of phosphate.
A Novel T-Fed 4-Element Quasi-Lumped Resonator Antenna Array
Directory of Open Access Journals (Sweden)
S.S. Olokede
2014-06-01
Full Text Available In this paper, electrically small corporately T-fed quasi-lumped element resonator antenna array is investigated. The radiating element, a quasi-lumped element resonator is excited by a novel semi hybrid ring-like T-shaped corporate feed network. The characteristics losses due to Ohmic and discontinuities along the feed line which invariably constitutes complex feed structures are mitigated at the instance of the proposed antenna. Technique to implement the compact array with the intent to enhance the gain is presented. The operation dynamics of the feed along with its theoretical explanation is also reported. Findings indicates that the measured gain is 10.97 dBi for antenna of an estate area of about 0.677λ_0 × 1.257λ_0 sq. mm. Valuable insight to the optimum design in terms of compactness, good gain, and ease of fabrication is documented.
IMPROVEMENT OF COAGULATION PROCESS FOR THE PRUT RIVER WATER TREATMENT USING ALUMINUM SULPHATE
Directory of Open Access Journals (Sweden)
Larisa Postolachi
2015-06-01
Full Text Available The aim of presented research was to optimize the treatment process of the Prut River water. In order to realize the proposed goal, there were studied the following factors which can improve the process of coagulation: (i the influence of stirring speed during coagulation and (ii the influence of the concentration of the coagulant solution added in the process of coagulation. The optimal conditions of coagulation were established using the Jar-test method. Application of the recommended procedure contribute to the reduction of the coagulant dose, the contact time, the aluminum concentration in water and the expenses for water treatment.
Coagulation profile of children with sickle cell anemia in steady state ...
African Journals Online (AJOL)
Background: Sickle cell anemia is associated with a hypercoagulable state that may lead to alterations in a coagulation profile. Measurements of coagulation factors are known to have some predictive value for clinical outcome. Objectives: To determine the coagulation profile of children with SCA in steady state and crisis ...
Disseminated intravascular coagulation (DIC)
... Jr, Silberstein LE, et al, eds. Hematology: Basic Principles and Practice . 6th ed. Philadelphia, PA: Elsevier Saunders; 2013:chap 141. Thachil J, Toh CH. Current concepts in the management of disseminated intravascular coagulation. Thromb Res . 2012;129 ...
Method for Lumped Parameter simulation of Digital Displacement pumps/motors based on CFD
DEFF Research Database (Denmark)
Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.
2013-01-01
Digital displacement fluid power pumps/motors offers improved efficiency and performance compared to traditional variable displacement pump/motors. These improvements are made possible by using efficient electronically controlled seat valves and careful design of the flow geometry. To optimize...... the design and control of digital displacement machines, there is a need for simulation models, preferably models with low computational cost. Therefore, a low computational cost generic lumped parameter model of digital displacement machine is presented, including a method for determining the needed model...... parameters based on steady CFD results, in order to take detailed geometry information into account. The response of the lumped parameter model is compared to a computational expensive transient CFD model for an example geometry....
Vitamin K: from coagulation to calcification.
Paakkari, Ilari
Vitamin K is not only essential for the synthesis of coagulation factors in the liver, but it also strengthens the bones and prevents calcification of the arteries. These effects are mediated through the same mechanism, i.e. carboxylation of Gla target proteins. The discovery of novel Gla proteins that are not associated with blood coagulation or calcium metabolism indicates that vitamin K has additional effects in the pancreas and the central nervous system, for example. As dietary supplements, vitamin K1 of plant origin and vitamins K2 of bacterial origin may exert different effects.
WATER PURIFICATION BY COAGULATION UNDER THE INFLUENCE OF ULTRASONIC FIELD
Directory of Open Access Journals (Sweden)
Vikulina Vera Borisovna
2016-03-01
Full Text Available The authors carried out experiments on the in-fluence of ultrasound on the subsidence of suspended materials. The efficiency of coagulation process in wa-ter purification in ultrasound field is estimated. The influence of ultrasound on the water with suspended materials before introducing coagulant was a condition of the experiment. The magnetostriction method for obtaining ultrasound oscillations with the help of ultra-sound generator of batch production was applied. The samples were chosen and the coagulation process was controlled using standard procedures. The experimental data was obtained which estimate the efficiency in-crease in the subsidence of suspended materials de-pending on the duration of ultrasound processing. Dur-ing one minute of ultrasound processing the following results were obtained: the subsidence efficiency in-creased by 25.83 % in case of coagulant share Al2O3 2.5 mg/l; the subsidence efficiency increased by 23.70 % in case of coagulant share Al2O3 5.0 mg/l.
International Nuclear Information System (INIS)
Tormoen, Garth W; Khader, Ayesha; Gruber, András; McCarty, Owen J T
2013-01-01
Thrombosis significantly contributes to cancer morbidity and mortality. The mechanism behind thrombosis in cancer may be circulating tissue factor (TF), as levels of circulating TF are associated with thrombosis. However, circulating TF antigen level alone has failed to predict thrombosis in patients with cancer. We hypothesize that coagulation factor levels regulate the kinetics of circulating TF-induced thrombosis. Coagulation kinetics were measured as a function of individual coagulation factor levels and TF particle concentration. Clotting times increased when pooled plasma was mixed at or above a ratio of 4:6 with PBS. Clotting times increased when pooled plasma was mixed at or above a ratio of 8:2 with factor VII-depleted plasma, 7:3 with factor IX- or factor X-depleted plasmas, or 2:8 with factor II-, V- or VIII-depleted plasmas. Addition of coagulation factors VII, X, IX, V and II to depleted plasmas shortened clotting and enzyme initiation times, and increased enzyme generation rates in a concentration-dependent manner. Only additions of factors IX and X from low-normal to high-normal levels shortened clotting times and increased enzyme generation rates. Our results demonstrate that coagulation kinetics for TF particles are controlled by factor IX and X levels within the normal physiological range. We hypothesize that individual patient factor IX and X levels may be prognostic for susceptibility to circulating TF-induced thrombosis. (paper)
Advantages and disadvantages of lumping together gastroesophageal reflux disease and dyspepsia
Smout, André J. P. M.
2006-01-01
PURPOSE OF REVIEW: The aim of this article is to identify and to balance the arguments in favor of and against lumping together gastroesophageal reflux disease and functional dyspepsia. RECENT FINDINGS: In at least half of the patients diagnosed with gastroesophageal reflux disease no organic
Definition of datum of materials lump size on conveyors by means of reflected gamma-radiation method
International Nuclear Information System (INIS)
Gal'yanov, A.V.; Antonov, V.A.; Laptev, Yu.V.
2001-01-01
A method of technological control of large-size lumps in conveyor-transported crushed material based on intensity measurement of X-ray and gamma radiation reflected from the material surface was suggested. The method was substantiated theoretically and as a result it was shown that dispersion of radiation intensity, multiply measured for short periods of time, can be analytic parameter of large-size lumps yield. Principled methodical and design recommendations on the method practical applications are given [ru
Coagulation and flocculation of dissolved organic substances with organic polymers
Kvinnesland, Thomas
2002-01-01
Coagulation of natural organic matter (NOM) in water is a well-established process, enabling or enhancing the removal of these substances by different particle separation processes. The dominating coagulating agents used are, however, inorganic salts of iron (Fe3+) and aluminium (Al3+). The primary use of organic polymers is as flocculating agents for already coagulated aggregates. However, in recent years the use of cationic organic polymers have received increasing attent...
Directory of Open Access Journals (Sweden)
S Koirala
2014-09-01
Full Text Available Background: Breast lump is one of the most common presentations in surgical outpatient departments with anxiety regarding a possible malignancy. Hence a quick diagnosis of a lump in the breast is essential. Fine needle aspiration cytology is an ideal initial diagnostic modality in breast lumps. There is an alternative method of performing needle aspiration, known as fine needle capillary cytology where the specimen is obtained using just a needle without aspiration.Materials and Methods: This hospital-based cross sectional analytical study was carried out in Department of Pathology in National Academy of Medical Sciences, Bir Hospital for one year. The objective of this study was to compare aspiration and non-aspiration cytology of palpable breast lumps and correlation with histopathology.Results: The five criteria scored for each technique were background blood, amount of cellular material, cellular degeneration, cellular trauma and architectural preservation. Compared to fine needle aspiration cytology, fine needle capillary cytology yields less bloody smears with minimal degenerative changes and offers more diagnostically superior specimens. Fine needle aspiration cytology, on the other hand, gives a good yield of diagnostic material.Conclusion: Fine needle aspiration cytology and fine needle capillary cytology are quick, easy, safe and cost-effective techniques. . A high sensitivity and specificity of cytological diagnosis in this study proves that it is comparable to final histology report in its diagnostic efficiency. Thus, fine needle aspiration cytology is a very important preliminary diagnostic test in palpable breast lumps and the results show a high degree of correlation with the final histopathology report.DOI: http://dx.doi.org/10.3126/jpn.v4i8.11501 Journal of Pathology of Nepal; Vol.4,No. 8 (2014 639-643
The performance of double layer structure membrane prepared from flowing coagulant
Mieow Kee, Chan; Xeng, Anthony Leong Chan; Regal, Sasiskala; Singh, Balvinder; Raoo, Preeshaath; Koon Eu, Yap; Sok Choo, Ng
2017-12-01
Membrane with double layer structure is favourable as it exhibits smooth surface and macrovoids free structure. However, its’ performance in terms of permeability, porosity and strength has not been studied thoroughly. Additionally, the effect of flowing coagulant on the formation of double layer membrane has not been reported. Thus, the objective of this study is to investigate the performance of double layer membranes, which were prepared using flowing coagulant. Results showed that when the coagulant flow changed from laminar to turbulent, the pure water permeation of the membrane increased. It was due to the higher porosity in the membrane, which prepared by turbulent flow (CA-Turbulent) compared to the membrane which fabricated under laminar condition (CA-Laminar). This can be explained by the rapid solvent-coagulant exchange rate between the polymer solution and the turbulent coagulant. In term of strength, the tensile strength of the CA-Turbulent was ~32 MPa, which was 100% higher compared to CA-Laminar. This may due to the presence of large amount of nodules on its surface, which reduced the surface integrity. In conclusion, flowing coagulant altered the membrane properties and adopting turbulent coagulant flow in membrane fabrication would improve the porosity, surface roughness and the strength of the membrane.
Coagulation and Adsorption Treatment of Printing Ink Wastewater
Directory of Open Access Journals (Sweden)
Maja Klančnik
2015-03-01
Full Text Available The intention of the study was to improve the efficiency of total organic carbon (TOC and colour removal from the wastewater samples polluted with flexographic printing ink following coagulation treatments with further adsorption onto activated carbons and ground orange peel. The treatment efficiencies were compared to those of further flocculation treatments and of coagulation and adsorption processes individually. Coagulation was a relatively effective single-treatment method, removing 99.7% of the colour and 86.9% of the organic substances (TOC from the printing ink wastewater samples. Further flocculation did not further eliminate organic pollutants, whereas subsequent adsorption with 7 g/l of granular activated carbon further reduced organic substances by 35.1%, and adsorption with 7 g/l of powdered activated carbon further reduced organic substances by 59.3%. Orange peel was an inappropriate adsorbent for wastewater samples with low amounts of pollution, such as water that had been treated by coagulation. However, in highly polluted printing ink wastewater samples, the adsorption treatment with ground orange peel achieved efficiencies comparable to those of the granular activated carbon treatments.
Novel approaches to the management of disseminated intravascular coagulation
Levi, M. [=Marcel M.; de Jonge, E.; van der Poll, T.; ten Cate, H.
2000-01-01
Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. We addressed the issue of whether there is evidence that this fibrin deposition contributes to multiple organ
A Pontential Agriculture Waste Material as Coagulant Aid: Cassava Peel
Othman, N.; Abd-Rahim, N.-S.; Tuan-Besar, S.-N.-F.; Mohd-Asharuddin, S.; Kumar, V.
2018-02-01
All A large amount of cassava peel waste is generated annually by small and medium scale industries. This has led to a new policy of complete utilization of raw materials so that there will be little or no residue left that could pose pollution problems. Conversion of these by-products into a material that poses an ability to remove toxic pollutant would increase the market value and ultimately benefits the producers. This study investigated the characteristics of cassava peel as a coagulant aid material and optimization process using the cassava peel was explored through coagulation and flocculation. This research had highlighted that the Cassava peels contain sugars in the form of polysaccharides such as starch and holocellulose. The FTIR results revealed that amino acids containing abundant of carboxyl, hydroxyl and amino groups which has significant capabilities in removing pollutants. Whereas analysis by XRF spectrometry indicated that the CP samples contain Fe2O3 and Al2O3 which might contribute to its coagulation ability. The optimum condition allowed Cassava peel and alum removed high turbidity up to 90. This natural coagulant from cassava peel is found to be an alternative coagulant aid to reduce the usage of chemical coagulants
Evaluation of Impact of Coagulant Type on Operation Parameters in Direct Filtration
Directory of Open Access Journals (Sweden)
Ali Torabian
2007-06-01
Full Text Available Numerous advantages have been reported on PAC (poly aluminum chloride used as a coagulant over other coagulants such as alum and ferric chloride used in conventional water treatment process with medium and high turbidity levels. These include lower amounts of PACL required specially in removing turbidity, larger floc grain formation, reduced floc sedimentation time, lower sludge production, and relaxation of the need for pH adjustment by lime, among others. The present study aims to evaluate the effects of different coagulants such as ferric chloride and PACL on direct filtration and to identify the most effective material based on both turbidity and particle removal efficiencies. A perfectly experimental pilot system, including raw water preparation, coagulation, flocculation, distribution measurement, and filtration units, was designed and used. Raw water turbidity level in the experimental pilot was below 10 NTU. The effects of various parameters such as coagulant type, filtration rate, and coagulant dosage on the performance of the filter were investigated. The results obtained from several filtration cycles under different conditions indicated that average effluent turbidity level, effluent particle numbers, effluent turbidity variation graph, and effluent particle graph were lower throughout the filtration cycle when PACL was used compared to when ferric chloride was used as the coagulant. Increasing filtration rate led to increased turbidity and particle number. Addition of 2 mg/l of PACL (poor coagulation and flocculation scenario was compared with addition of 5 mg/l of ferric chloride (strong coagulation and flocculation scenario. The results indicated that higher average values of turbidity removal but lower turbidity and particle removal efficiencies obtained in the case of the poor coagulation and flocculation scenario.
Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean
Directory of Open Access Journals (Sweden)
Prodanović Jelena M.
2015-01-01
Full Text Available Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with 0.5 mol/L NaCl. The obtained raw extract was used as a coagulant. The coagulation efficiency was measured by jar test at different pH values of wastewater, and a decrease in organic matter content was determined. The experiments confirmed that natural coagulant from common bean could be successfully used for the treatment of extraction juice distillery wastewater. The highest coagulation efficiencies were achieved at the pH 5.2 with a coagulant dose of 30 mL/L, and at the pH 8.5 with a coagulant dose of 5 mL/L, and they were 64.71% and 68.75% respectively. These encouraging results indicate that natural coagulant from common bean seeds is a potential alternative to conventional chemical coagulant/flocculant agents for treatment of wastewaters.[Projekat Ministarstva nauke Republike Srbije, br. III 43005
New Procedure to Develop Lumped Kinetic Models for Heavy Fuel Oil Combustion
Han, Yunqing; Elbaz, Ayman M.; Roberts, William L.; Im, Hong G.
2016-01-01
A new procedure to develop accurate lumped kinetic models for complex fuels is proposed, and applied to the experimental data of the heavy fuel oil measured by thermogravimetry. The new procedure is based on the pseudocomponents representing
Operating Conditions of Coagulation-Flocculation Process for High Turbidity Ceramic Wastewater
Directory of Open Access Journals (Sweden)
Sameer Al-Asheh
2017-04-01
Full Text Available This work attempted to determine the optimum conditions required for the coagulation and flocculation process as an essential stage of the ceramic wastewater treatment. Coagulation and flocculation is a very necessary step in industries as it lessens turbidity, color, and odor of wastewater. The experimental work was performed in several runs. The volume of wastewater used in each run was 200 mL and was kept at this value throughout. In certain runs, the speed of the mixer was varied while keeping the quantity of coagulant and flocculant constant in order to determine the optimum speed that resulted in the least turbidity. A speed of 5% was chosen as the ideal process speed according to the results obtained. Next, experiments were operated at this optimum speed while changing the dosage of coagulant and flocculant in order to decide the optimum dosage. Coagulant and flocculent amounts of 0.4 g (without booster and 0.2 g (with booster selected after the readings were taken. For all the readings, a turbidity meter was used providing results in Nephelometric Turbidity Units (NTU. Lowest turbidity was achieved when using 5% speed with 0.4 grams of coagulant and 0.4 grams of flocculant, or 5% speed with 0.2 grams of coagulant, 0.2 grams of flocculant and 0.25 g/L of booster coagulant. According to factorial design analysis, such as parameters as impeller speed and dosage have an influential impact on the turbidity; while the booster has insignificant influence and other interactions between parameters are important.
Treatment of sugar beet thick juice spent wash by chemical and natural coagulants
Antov Mirjana G.; Klašnja Mile T.; Šćiban Marina B.
2009-01-01
The possibility of treatment of wastewater from bioethanol production by aluminium sulfate and natural coagulant extracted from common bean seed was studied. The highest coagulation activity at pH 6.5 is reached with analum dose of 1 g/l, but only a little lower coagulation activities were obtained by the dose of 0.05 and 0.10 g/l, which is more favorable for economic and environmental reasons. When natural coagulant from common bean was applied the highest coagulation activity, 14.3%, at pH ...
International Nuclear Information System (INIS)
Maliaritsi, E.; Zoumpoulakis, L.; Simitzis, J.; Vassiliou, P.; Hristoforou, E.
2006-01-01
Coagulation sensors based on the magnetostrictive delay line technique are presented in this paper. They are based on magnetostrictive ribbons and are used for measuring the coagulation, curing or solidification time of different liquids. Experimental results indicate that the presented sensing elements can determine the blood coagulation with remarkable repeatability, thus allowing their use as blood coagulation sensors. Additionally, results indicate that they can also measure curing time of resins, solidification of fluids and coagulation of chemical substances, therefore allowing their implementation in chemical engineering applications
International Nuclear Information System (INIS)
Irfan, M.
2008-01-01
This study was conducted by author as a member of Specialty Chemical Division of Sitara Chemical Industries which is the largest chlor -alkali manufacturing industry in Pakistan. Sitara is also producing FeCl/sub 3/ as a byproduct to consume its additional quantity of chlorine produced during electrolysis of brine solution for caustic soda preparation. Most of the industries are using Alum along with other polymers for treatment of effluent waste water. Treatment system is based on sand bed filters. For coagulation of unwanted materials present in the water, Alum is being used with Anionic Polymer (Accofloc-A2125) as flocculent. But the ferric chloride is not only functions as a reactants to remove water impurities but it also functions as a both coagulant and a Flocculent. This study was conducted for finding best alternative chemicals to improve treated water quality. For this purpose Ferric Chloride (FeCl/sub 3/) is used as best alternative of alum for better removal of turbidity, heavy metals and micro organisms to eradicate above said problems and for better removal of turbidity, heavy metals and micro, organisms to eradicate health problems. As per lab scale results quality of treated water with Ferric Chloride (FeCl/sub 3/) proved better than that of Alum. The main objective of this research is to investigate the efficiency of coagulation and flocculation processes for removing suspended solids, colour and COD which present in significant quantity. Three types of coagulants were examined using standard jar test apparatus, i.e., aluminum sulphate (alum), ferric chloride (FeCl/sub 3/) and ferrous sulphate (FeSO/sub 4/). The effects of agitation speed, settling time, pH, coagulant dosages and temperature were examined. At 300 rpm of rapid mixing and 50 rpm of slow mixing and 60 minutes settling time, higher removals of suspended solids (over 95%), colour (90%) and COD (43%) were achieved at pH 4 and 12. FeCl/sub 3/ was found to be superior compared with other
Using Coagulation Process in Optimizing Natural Organic Matter Removal from Low Turbidity Waters
Directory of Open Access Journals (Sweden)
Alireza Mesdaghinia
2006-03-01
Full Text Available Optimization of coagulation process for efficient removal of Natural Organic Matters (NOM has gained a lot of focus over the last years to meet the requirements of enhanced coagulation. NOM comprises both particulate and soluble components which the latter usually comprises the main portion. Removal of soluble NOM from low turbidity waters by coagulation is not a successful process unless enough attention is paid to stages of formation and development of both micro and macro-flocs. This study, which presents experimental results from pilot scale research studies aimed at optimizing coagulation process applied to synthetic raw waters supplemented by adding commercial humic acid with low turbidity levels, explains how pH and turbidity can be controlled to maximize soluble NOM removal. The removal of NOM at various coagulant doses and coagulation pHs has been assessed through raw and treated (coagulated-settled water measurements of total organic carbon (TOC. For low turbidity waters, essential floc nucleation sites can be provided by creating synthetic turbidities, for example by adding clay. Adjusting the initial pH at 5.5 or adding clay before coagulant addition allows the formation of micro-flocs as well as formation of the insoluble flocs at low coagulant doses.
Directory of Open Access Journals (Sweden)
Antonio Belmonte
2018-04-01
Full Text Available This paper presents a new algorithm for the resolution of over-constrained lumped process systems, where partial differential equations of a continuous time and space model of the system are reduced into ordinary differential equations with a finite number of parameters and where the model equations outnumber the unknown model variables. Our proposal is aimed at the study and improvement of the algorithm proposed by Hangos-Szerkenyi-Tuza. This new algorithm improves the computational cost and solves some of the internal problems of the aforementioned algorithm in its original formulation. The proposed algorithm is based on parameter relaxation that can be modified easily. It retains the necessary information of the lumped process system to reduce the time cost after introducing changes during the system formulation. It also allows adjustment of the system formulations that change its differential index between simulations.
Charging and coagulation of radioactive and nonradioactive particles in the atmosphere
International Nuclear Information System (INIS)
Kim, Yong-ha; Yiacoumi, Sotira
2016-01-01
Charging and coagulation influence one another and impact the particle charge and size distributions in the atmosphere. However, few investigations to date have focused on the coagulation kinetics of atmospheric particles accumulating charge. This study presents three approaches to include mutual effects of charging and coagulation on the microphysical evolution of atmospheric particles such as radioactive particles. The first approach employs ion balance, charge balance, and a bivariate population balance model (PBM) to comprehensively calculate both charge accumulation and coagulation rates of particles. The second approach involves a much simpler description of charging, and uses a monovariate PBM and subsequent effects of charge on particle coagulation. The third approach is further simplified assuming that particles instantaneously reach their steady-state charge distributions. It is found that compared to the other two approaches, the first approach can accurately predict time-dependent changes in the size and charge distributions of particles over a wide size range covering from the free molecule to continuum regimes. The other two approaches can reliably predict both charge accumulation and coagulation rates for particles larger than about 0.04 micrometers and atmospherically relevant conditions. These approaches are applied to investigate coagulation kinetics of particles accumulating charge in a radioactive neutralizer, the urban atmosphere, and an atmospheric system containing radioactive particles. Limitations of the approaches are discussed.
Simultaneous lactic acidification and coagulation by using recombinant Lactococcus lactis strain.
Raftari, M; Ghafourian, S; Abu Bakar, F
2017-04-01
This study was an attempt to create a novel milk clotting procedure using a recombinant bacterium capable of milk coagulation. The Rhizomucor pusillus proteinase (RPP) gene was sub-cloned into a pALF expression vector. The recombinant pALF-RPP vector was then electro-transferred into Lactococcus lactis. Finally, the milk coagulation ability of recombinant L. lactis carrying a RPP gene was evaluated. Nucleotide sequencing of DNA insertion from the clone revealed that the RPP activity corresponded to an open reading frame consisting of 1218 bp coding for a 43·45 kDa RPP protein. The RPP protein assay results indicated that the highest RPP enzyme expression with 870 Soxhlet units (SU) per ml and 7914 SU/OD were obtained for cultures which were incubated at pH 5·5 and 30°C. Interestingly, milk coagulation was observed after 205 min of inoculating milk with recombinant L. lactis carrying the RPP gene. The recombinant L. lactis carrying RPP gene has the ability to function as a starter culture for acidifying and subsequently coagulating milk by producing RPP as a milk coagulant agent. Creating a recombinant starter culture bacterium that is able to coagulate milk. It is significant because the recombinant L. lactis has the ability to work as a starter culture and milk coagulation agent. © 2016 The Society for Applied Microbiology.
Assessment of managed aquifer recharge potential using ensembles of local models.
Smith, Anthony J; Pollock, Daniel W
2012-01-01
A simple quantitative approach for assessing the artificial recharge potential of large regions using spatial ensembles of local models is proposed. The method extends existing qualitative approaches and enables rapid assessments within a programmable environment. Spatial discretization of a water resource region into continuous local domains allows simple local models to be applied independently in each domain using lumped parameters. The ensemble results can be analyzed directly or combined with other quantitative and thematic information and visualized as regional suitability maps. A case study considers the hydraulic potential for surface infiltration across a large water resource region using a published analytic model for basin recharge. The model solution was implemented within a geographic information system and evaluated independently in >21,000 local domains using lumped parameters derived from existing regional datasets. Computer execution times to run the whole ensemble and process the results were in the order of a few minutes. Relevant aspects of the case study results and general conclusions concerning the utility and limitations of the method are discussed. © 2011, CSIRO. Ground Water © 2011, National Ground Water Association.
Critical assessment of chitosan as coagulant to remove cyanobacteria
Lürling, Miquel; Noyma, Natalia Pessoa; Magalhães, Leonardo de; Miranda, Marcela; Mucci, Maíra; Oosterhout, Frank van; Huszar, Vera L.M.; Marinho, Marcelo Manzi
2017-01-01
Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial
Critical assessment of chitosan as coagulant to remove cyanobacteria
Lurling, Miguel; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Mucci, Maíra; Oosterhout, van F.; Huszar, Vera L.M.; Marinho, Marcelo Manzi
2017-01-01
Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial
Coagulation mechanism of salt solution-extracted active component in Moringa oleifera seeds
Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa
2001-01-01
This study focuses on the coagulation mechanism by the purified coagulant solution (MOC-SC-PC) with the coagulation active component extracted from M. oleifera seeds using salt solution. The addition of MOC-SC-PC into tap water formed insoluble matters. The formation was responsible for kaolin coagulation. On the other hand, insoluble matters were not formed when the MOC-SC-PC was added into distilled water. The formation was affected by Ca2+ or other bivalent cations which may connect each m...
Improvement of extraction method of coagulation active components from Moringa oleifera seed
Okuda, Tetsuji; Baes, Aloysius U.; Nishijima, Wataru; Okada, Mitsumasa
1999-01-01
A new method for the extraction of the active coagulation component from Moringa oleifera seeds was developed and compared with the ordinary water extraction method (MOC–DW). In the new method, 1.0 mol l-1 solution of sodium chloride (MOC–SC) and other salts were used for extraction of the active coagulation component. Batch coagulation experiments were conducted using 500 ml of low turbid water (50 NTU). Coagulation efficiencies were evaluated based on the dosage required to remove kaolinite...
Primary Breast Tuberculosis Presenting as a Lump: A Rare Modern ...
African Journals Online (AJOL)
A 25‑year‑old female presented with a painless lump in her right breast for 1 month duration. She gave history of low grade fever off and on for the last 2 weeks. There were no other complaints like weight loss, loss of appetite, and any cough. She was unmarried and there was no positive family history of breast tuberculosis.
OPTIMISATION OF HIBISCUS SABDARIFFA AS A NATURAL COAGULANT TO TREAT CONGO RED IN WASTEWATER
Directory of Open Access Journals (Sweden)
MUN Y. YONG
2016-02-01
Full Text Available The process of coagulation is commonly practiced in water and wastewater treatment to reduce level of dissolved chemical, turbidity and so on with the usage of coagulant. Aluminium sulphate (alum is the most commonly used coagulant, however, recent studies show that residual aluminium in drinking water and sludge may induce Alzheimer’s disease and environmental issues. Natural coagulant which is environmental friendly and non-toxic is developed as an alternative to overcome these issues. In this work, Hibiscus Sabdariffa was studied as natural coagulant to treat dye wastewater containing Congo red. The seeds were extracted with different solvent such as distilled water, 0.5 M NaCl and 0.05 M NaOH to extract the coagulation agent. The working parameters were optimised using Response Surface Methodology (RSM. 0.5 M NaCl was found to have highest colour removal of 95.1 % among the solvents. In addition, Hibiscus Sabdariffa seed was found to be an effective coagulant that has 91.2 % colour removal at the optimal working condition of pH 2, 190 mg/L coagulant dosage at 400 ppm of dye concentration. It was also been identified that the performance of natural coagulant is comparable with conventional coagulant, aluminium sulphate with colour removal of 91.2 % and 92.3 % respectively.
Removal of Arsenic from Drinking Water by Adsorption and Coagulation
Zhang, M.; Sugita, H.; Hara, J.; Takahashi, S.
2013-12-01
Removal of arsenic from drinking water has been an important issue worldwide, which has attracted greater attentions in recent years especially for supplying safe drinking water in developing countries. Although many kinds of treatment approaches that are available or applicable both in principle and practice, such as adsorption, coagulation, membrane filtration, ion exchange, biological process, electrocoagulation and so on, the first 2 approaches (i.e., adsorption and coagulation) are most promising due to the low-cost, high-efficiency, simplicity of treating systems, and thus can be practically used in developing countries. In this study, a literature survey on water quality in Bangladesh was performed to understand the ranges of arsenic concentration and pH of groundwater in Bangladesh. A series of tests were then organized and performed to investigate the effects of arsenic concentration, arsenic forms, pH, chemical compositions of the materials used for adsorption and coagulation, particle size distribution and treatment time on quality of treated water. The experimental results obtained in the study illustrated that both adsorption and coagulation can be used to effectively reduce the concentrations of either arsenic (V) or arsenic (III) from the contaminated water. Coagulation of arsenic with a magnesium-based material developed in this study can be very effective to remove arsenic, especially arsenic (V), from contaminated water with a concentration of 10 ppm to an undetectable level of 0.002 ppm by ICP analyses. Compared to arsenic (III), arsenic (V) is easier to be removed. The materials used for adsorption and coagulation in this study can remove arsenic (V) up to 9 mg/g and 6 mg/g, and arsenic (III) up to 4 mg/g and 3 mg/g, respectively, depending on test conditions and compositions of the materials being used. The control of pH during treatment can be a challenging technical issue for developing both adsorbent and coagulant. Keywords: Water Treatment
Bladder perforation owing to a unipolar coagulating device.
Pakter, J; Budnick, L D
1981-09-15
A report on a patient who sustained a burn and perforation of the urinary bladder from visible sparks emanating from a unipolar coagulating device during the couse of laparoscopic sterilization is presented. It is the first report of urinary bladder burns using a unipolar coagulating device. A 24-year-old woman, gravida 10, para 3, abortus 7, underwent a laparoscopic sterilization with a unipolar coagulating device. As the physician was finishing the coagulation, a spark from the device caused a 1-2 cm burn with a central area of perforation into the urinary bladder. Conservative treatment was recommended, and consisted of Foley catheterization and drainage for 5 days. Initial urine culture revealed Klebsiella species, and oral ampicillin was prescribed. Hematuria was noted throughout the patient's hospitalization, and blood clots were present in the urine on Day 2 postoperation. The patient had no abdominal or flank pain, was afebrile, and had a stable hemoglobin level during the hospital stay. Cystography was performed on Day 5 postoperatively and demonstrated no perforation. Foley catheter was removed. Patient was discharged 2 days later and remains in good health 3 months postoperatively.
Effects of Puff-Adder Venom on Coagulation, Fibrinolysis and ...
African Journals Online (AJOL)
The in vitro and in vivo haematological effects of puffadder (Bitis arietans) venom in the baboon (Papio ursinus) with regard to its effect on coagulation, fibrinolysis and platelet aggregation were studied. There is a delay in the intrinsic coagulation mechanism with fibrinolysis and in vitro fibrinogenolysis. Normal human ...
Directory of Open Access Journals (Sweden)
Florry E van den Boogaard
Full Text Available Pulmonary coagulopathy is intrinsic to pulmonary injury including pneumonia. Anticoagulant strategies could benefit patients with pneumonia, but systemic administration of anticoagulant agents may lead to suboptimal local levels and may cause systemic hemorrhage. We hypothesized nebulization to provide a safer and more effective route for local administration of anticoagulants. Therefore, we aimed to examine feasibility and safety of nebulization of recombinant human tissue factor pathway inhibitor (rh-TFPI in a well-established rat model of Streptococcus (S. pneumoniae pneumonia. Thirty minutes before and every 6 hours after intratracheal instillation of S. pneumonia causing pneumonia, rats were subjected to local treatment with rh-TFPI or placebo, and sacrificed after 42 hours. Pneumonia was associated with local as well as systemic activation of coagulation. Nebulization of rh-TFPI resulted in high levels of rh-TFPI in bronchoalveolar lavage fluid, which was accompanied by an attenuation of pulmonary coagulation. Systemic rh-TFPI levels remained undetectable, and systemic TFPI activity and systemic coagulation were not affected. Histopathology revealed no bleeding in the lungs. We conclude that nebulization of rh-TFPI seems feasible and safe; local anticoagulant treatment with rh-TFPI attenuates pulmonary coagulation, while not affecting systemic coagulation in a rat model of S. pneumoniae pneumonia.
International Nuclear Information System (INIS)
Silva, Alice Cunha da; Su, Jian
2013-01-01
The High Temperature Gas cooled Reactor (HTGR) is a fourth generation thermal nuclear reactor, graphite-moderated and helium cooled. The HTGRs have important characteristics making essential the study of these reactors, as well as its fuel element. Examples of these are: high thermal efficiency,low operating costs and construction, passive safety attributes that allow implication of the respective plants. The Pebble Bed Modular Reactor (PBMR) is a HTGR with spherical fuel elements that named the reactor. This fuel element is composed by a particulate region with spherical inclusions, the fuel UO2 particles, dispersed in a graphite matrix and a convective heat transfer by Helium happens on the outer surface of the fuel element. In this work, the transient heat conduction in a spherical fuel element of a pebble-bed high temperature reactor was studied in a transient situation of combined convective and radiative cooling. Improved lumped parameter model was developed for the transient heat conduction in the two-layer composite sphere subjected to combined convective and radiative cooling. The improved lumped model was obtained through two-point Hermite approximations for integrals. Transient combined convective and radiative cooling of the two-layer spherical fuel element was analyzed to illustrate the applicability of the proposed lumped model, with respect to die rent values of the Biot number, the radiation-conduction parameter, the dimensionless thermal contact resistance, the dimensionless inner diameter and coating thickness, and the dimensionless thermal conductivity. It was shown by comparison with numerical solution of the original distributed parameter model that the improved lumped model, with H2,1/H1,1/H0,0 approximation yielded significant improvement of average temperature prediction over the classical lumped model. (author)
Distribution functions and moments in the theory of coagulation
International Nuclear Information System (INIS)
Pich, J.
1990-04-01
Different distribution functions and their moments used in the Theory of coagulation are summarized and analysed. Relations between the moments of these distribution functions are derived and the physical meaning of individual moments is briefly discussed. The time evolution of the moment of order zero (total number concentration) during the coagulation process is analysed for the general kernel of the Smoluchowski equation. On this basis the time evolution of certain physically important quantities related to this moment such as mean particle size, surface and volume as well as surface concentration is described. Equations for the half time of coagulation for the general collision frequency factor are derived. (orig.) [de
Optimum Design and Operation of Cyclic Storage Systems; Lumped Approach
Directory of Open Access Journals (Sweden)
Leila Ostadrahimi
2007-01-01
Full Text Available Conjunctive use of surface and groundwater resources is a preferred approach in water resources management. Compared to dam construction, groundwater has certain advantages, among which are less costs, less sedimentation and evaporation, fewer water quality problems, and less social and cultural problems. To reduce the major problems associated with the development of large-scale surface impoundment systems, cyclic storage systems can be used as an alternative. A cyclic storage system (CYCS is an integrated interactive system consisting of two subsystems of surface water storage (reservoir and groundwater; this system together with artificial recharge is able to satisfy the predefined demands with rather high reliability. In order to optimize these systems, one must consider the hydraulic interactions between all the components, but unfortunately it has been neglected in many studies. In this article, a nonlinear optimization model for design and operation of cyclic storage systems has been developed using the lumped approach. In order to evaluate the model, its results have been compared with the results of a model in which distributed approach had been deployed, and so the efficiency of lumped models to solve the problems of cyclic storage systems has been investigated.
Breast Lumps: A 21‑Year Single‑Center Clinical and Histological ...
African Journals Online (AJOL)
Results: Only 38% of the patients came within 3 months of finding lumps in their breast. Onehundred and thirty‑seven patients (83%) had benign disease, i.e., fibroadenoma, mammary dysplasia, cysts, adenomas, tuberculosis, phyllodes tumor, mastitis, and lipoma. Only 16.9% i.e., 28 patients had breast cancer, out of which ...
International Nuclear Information System (INIS)
Prettyman, T.H.; Sprinkle, J.K. Jr.; Sheppard, G.A.
1993-01-01
With transmission-corrected gamma-ray nondestructive assay instruments such as the Segmented Gamma Scanner (SGS) and the Tomographic Gamma Scanner (TGS) that is currently under development at Los Alamos National Laboratory, the amount of gamma-ray emitting material can be underestimated for samples in which the emitting material consists of particles or lumps of highly attenuating material. This problem is encountered in the assay of uranium and plutonium-bearing samples. To correct for this source of bias, we have developed a least-squares algorithm that uses transmission-corrected assay results for several emitted energies and a weighting function to account for statistical uncertainties in the assay results. The variation of effective lump size in the fitted model is parameterized; this allows the correction to be performed for a wide range of lump-size distributions. It may be possible to use the reduced chi-squared value obtained in the fit to identify samples in which assay assumptions have been violated. We found that the algorithm significantly reduced bias in simulated assays and improved SGS assay results for plutonium-bearing samples. Further testing will be conducted with the TGS, which is expected to be less susceptible than the SGS to systematic source of bias
International Nuclear Information System (INIS)
Yilmaz, A. Erdem; Boncukcuoglu, Recep; Kocakerim, M. Muhtar
2007-01-01
This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively
Energy Technology Data Exchange (ETDEWEB)
Yilmaz, A. Erdem [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey)], E-mail: aerdemy@atauni.edu.tr; Boncukcuoglu, Recep [Atatuerk University, Faculty of Engineering, Department of Environmental Engineering, 25240 Erzurum (Turkey); Kocakerim, M. Muhtar [Atatuerk University, Faculty of Engineering, Department of Chemical Engineering, 25240 Erzurum (Turkey)
2007-10-22
This paper provides a quantitative comparison of electrocoagulation and chemical coagulation approaches based on boron removal. Electrocoagulation process delivers the coagulant in situ as the sacrificial anode corrodes, due to a fixed current density, while the simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation. By comparison, conventional chemical coagulation typically adds a salt of the coagulant, with settling providing the primary pollutant removal path. Chemical coagulation was carried out via jar tests using aluminum chloride. Comparison was done with the same amount of coagulant between electrocoagulation and chemical coagulation processes. Boron removal obtained was higher with electrocoagulation process. In addition, it was seen that chemical coagulation has any effect for boron removal from boron-containing solution. At optimum conditions (e.g. pH 8.0 and aluminum dose of 7.45 g/L), boron removal efficiencies for electrocoagulation and chemical coagulation were 94.0% and 24.0%, respectively.
Arsenic removal in water by means of coagulation-flocculation processes
International Nuclear Information System (INIS)
Franco, M. F.; Carro P, M. E.
2014-01-01
Arsenic and arsenical compounds are considered as carcinogenic and risky for humans according to epidemiological evidence related with the ingestion of arsenical water during a long period. In many places the only source of drinking water contains arsenic and, therefore, removal strategies have to be investigated. This work shows experimental results of coagulation-flocculation processes implemented to evaluate the efficiency in the removal of arsenic from drinking water. The main objectives include the evaluation of the relevant aspect that controls the removal efficiency. Experimental tests were performed with coagulant concentrations from 5 to 500 mg/L, solid particle concentrations from 0 to 6000 mg/L, and initial arsenic concentrations from 0.5 to 5 mg/L. These variables were simultaneously varied in more than 100 experiments. The efficiency in remediation ranged from 0% to 95%. Removal efficiency near 95% was obtained when using ferric chloride as coagulant, and was close to 80% when using aluminium sulfate as coagulant in arsenate solutions. The remediation efficiency decreased significantly when the ferric chloride concentration was higher than 50 mg/L in relation to the obtained results for aluminum sulfate for different type and concentration of soil particles. The highest removal efficiency were obtained at ph between 3 and 5 in oxidized solutions. Obtained results simulated by means of multiple linear regression analysis (R>0.90) allow determining that the main parameters that control the removal of arsenic from drinking water are coagulant concentration, ph, and solid particles concentration. Conversely, particle mineralogy and coagulant type have less significant effect on the removal by means of coagulation-flocculation mechanisms. Obtained results are relevant for the removal of As in water treatment plants as well as for the development of small scale filters. The samples were studied by scanning electron microscopy and energy dispersive X
International Nuclear Information System (INIS)
Wambsganss, M.W.
1989-01-01
In this technical note, mass-spring-dashpot, also referred to as equivalent lumped parameter, models are employed to model the soil-foundation interaction of two typical floor segments from the 7-GeV APS experiment hall. Equivalent lumped parameter models have the advantage of being easy to apply and of readily allowing for parameter studies. Analysis requires knowledge of certain properties of the soil including density, shear wave velocity, and Poisson's ratio, as well as knowledge of the degree of homogeneity of the underlying soil stratum. These data for the APS site were determined by a geotechnical investigation. A soil profile and pertinent data, obtained from crosshole seismic testing, are given. Natural frequencies and damping are calculated for the vertical, sliding, rocking, and coupled rocking/sliding modes of vibration. Subsequently, various corrections to account for modeling ''deficiencies'' are considered and their influences evaluated. The equivalent lumped parameter models were developed for machine foundations which, compared with the APS foundation, are smaller in plan dimension. Therefore, the applicability of these models in the analysis of the dynamic characteristics of the APS foundation must be established. The modeling is evaluated by applying the equivalent lumped parameter models in the analysis of large foundations for which test data exists. A comparison of theoretical and test results establishes the basis for an assessment of the applicability and accuracy of the modeling
Effect of THI on milk coagulation properties of Holstein-Friesian dairy cattle
Directory of Open Access Journals (Sweden)
Simone Beux
Full Text Available ABSTRACT The objective of this study was to evaluate the effect of temperature-humidity index (THI on the milk coagulation properties of Holstein-Friesian dairy cattle from northeast part of Italy. A total of 592 individual milk samples from six dairy herds were evaluated. The milk coagulation properties traits analysed were milk rennet coagulation time and curd firmness, as well as the fat, protein, and casein contents, pH, milk aptitude to coagulate (IAC, and the somatic cell count. The THI was determined during the periods of sample collection. The THI results showed that values of up to 75 did not significantly change the IAC values; however, when the THI values were above 75, the IAC decreased significantly. The control of THI can be used to guarantee appropriate milk coagulation properties.
Influential factors of formation kinetics of flocs produced by water treatment coagulants.
Wu, Chunde; Wang, Lin; Hu, Bing; Ye, Jian
2013-05-01
The growth rate and size of floc formation is of great importance in water treatment especially in coagulation process. The floc formation kinetics and the coagulation efficiency of synthetic water were investigated by using an on-line continuous optical photometric dispersion analyze and the analysis of water quality. Experimental conditions such as alum dosage, pH value for coagulation, stirring intensity and initial turbidity were extensively examined. The photometric dispersion analyze results showed that coagulation of kaolin suspensions with two coagulants (alum and polyaluminium chloride) could be taken as a two-phase process: slow and rapid growth periods. Operating conditions with higher coagulant doses, appropriate pH and average shear rate might be particularly advantageous. The rate of overall floc growth was mainly determined by a combination of hydraulic and water quality conditions such as pH and turbidity. The measurement of zeta potential indicates that polyaluminium chloride exhibited higher charge-neutralizing ability than alum and achieved lower turbidities than alum for equivalent Al dosages. Under the same operating conditions, the alum showed a higher grow rate, but with smaller floc size.
Coagulation-flocculation studies of laboratory wastewater using different combinations
International Nuclear Information System (INIS)
Butt, M. T.; Khan, R. A.; Khokar, A.; Iqbal, K.
2013-01-01
This study was conducted on the wastewater of PCSIR Laboratories complex Lahore. Both single as well as blended form was used in order to achieve maximum results and to reduce the cost. These experiments were conducted in Hudson Jars of one liter capacity using the coagulation technique for the removal of total suspended solids (TSS) and turbidity. The pH range was 6-8 and 4-10 for treatment. Four coagulants were used such as FeCl 3 , AlCl 3 . Alum and FeSO 4 , to remove the turbidity in single and blended form. Results of single coagulant are FeCl 3 from 39.7 to 11.51 NTU; AlCl 3 from 47.48 to 11.8 NTU. Alum 43 to 25.3NTU.FeSO 4 showed increasing trend in turbidity 53 to 120 NTU. The blended set of coagulants AlCl 3 +Alum turbidity from 45 to 18.55 NTU. The AlCl 3 and FeCl 3 showed almost similar results but after overnight settling results were excellent and alum showed also good results. The turbidity was removed from 54 to 27 NTU, 48 to 22 NTU, 44 to 17 NTU, and after overnight settling 33 to 4 NTU. The results of blended coagulants FeCl 3 +AlCl 3 after one, two and three hours settling were also studied and found best and blend AlCl3+Alum showed also similar trend and the blend of Alum+FeCl 3 after overnight settling was excellent. The same coagulants and its blended form were used for TSS removal and results are 278 to 7 mg/L, in blended form AlCl 3 +Alum show similar results but Alum + FeCl 3 showed excellent results. The TSS and turbidity removal was 87%, 97.5%. (author)
International Nuclear Information System (INIS)
Wang Chi; Zhou Yu-Qiu; Shen Gao-Wei; Wu Wen-Wen; Ding Wei
2013-01-01
The method of numerical analysis is employed to study the resonance mechanism of the lumped parameter system model for acoustic mine detection. Based on the basic principle of the acoustic resonance technique for mine detection and the characteristics of low-frequency acoustics, the ''soil-mine'' system could be equivalent to a damping ''mass-spring'' resonance model with a lumped parameter analysis method. The dynamic simulation software, Adams, is adopted to analyze the lumped parameter system model numerically. The simulated resonance frequency and anti-resonance frequency are 151 Hz and 512 Hz respectively, basically in agreement with the published resonance frequency of 155 Hz and anti-resonance frequency of 513 Hz, which were measured in the experiment. Therefore, the technique of numerical simulation is validated to have the potential for analyzing the acoustic mine detection model quantitatively. The influences of the soil and mine parameters on the resonance characteristics of the soil—mine system could be investigated by changing the parameter setup in a flexible manner. (electromagnetism, optics, acoustics, heat transfer, classical mechanics, and fluid dynamics)
Evaluation of Chitin as Natural Coagulant in Water Treatment
Directory of Open Access Journals (Sweden)
V. Saritha
2012-04-01
Full Text Available The use of synthetic coagulants is not regarded as suitable due to health and economic considerations. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitin as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The experiment was conducted at three different pH conditions of 6, 7 and 8. The dosages chosen were 0.5, 1, 1.5 and 2mg/l. The results showed that turbidity decrease provided also a primary Escherichia coli reduction. Hardness removal efficiency was observed to be 93% at pH 7 with 1mg/l concentration by alum whereas chitin was stable at all the pH ranges showing highest removal at 1 and 1.5mg/l with pH 7. At low concentration chitin showed marginally better performance on hardness. In conclusion, using natural coagulants results in considerable savings in chemicals and sludge handling cost may be achieved.
Directory of Open Access Journals (Sweden)
Muna Yousif Abdul. Ahad
2015-05-01
Full Text Available Coagulation - flocculation are basic chemical engineering method in the treatment of metal-bearing industrial wastewater because it removes colloidal particles, some soluble compounds and very fine solid suspensions initially present in the wastewater by destabilization and formation of flocs. This research was conducted to study the feasibility of using natural coagulant such as okra and mallow and chemical coagulant such as alum for removing Cu and increase the removal efficiency and reduce the turbidity of treated water. Fourier transform Infrared (FTIR was carried out for okra and mallow before and after coagulant to determine their type of functional groups. Carbonyl and hydroxyl functional groups on the surface of okra and mallow were the major groups responsible for coagulation process. By using alum (conventional coagulants, okra and mallow (as a primary coagulant or in combination with the other two primary coagulants and by the jar testing, the optimum pH-value and dose of the coagulants were determined. The results indicated that the optimal pH values were 6.7, 8 and 6 for alum, okra and mallow, respectively. Mathematical modeling show significant results (sig.<0.05 for the % Cu removal (dependent variable with respect to coagulant dose (independent variable for the okra as a primary coagulant, alum with okra and alum with mallow as binary coagulants and alum, okra and mallow as ternary coagulants .
Indian Academy of Sciences (India)
Factor VIII (FVIII) functions as a co-factor in the blood coagulation cascade for the proteolytic activation of factor X by factor IXa. Deficiency of FVIII causes hemophilia A, the most commonly inherited bleeding disorder. This review highlights current knowledge on selected aspects of FVIII in which both the scientist and the ...
Removal of algal blooms from freshwater by the coagulation-magnetic separation method.
Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck
2013-01-01
This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.
PILOT PLANT STUDY ON NATURAL WATER COAGULANTS AS COAGULAN AIDS FOR WATER SUPPLY
Directory of Open Access Journals (Sweden)
B BINA
2001-06-01
Full Text Available Introduction: Natural plant coagulants have an important role to play in provision of portable water to rural communities in the developing world. The plant material that their coagulation properties have been confirmed in previous lab scale studies and can be found widely in Iran was selected as coagulant aids. Pilot plant study was done to evaluate the efficiency of natural material such as Starch/Gum Tragacanth, Fenugreek and Yeast as coagulant aids in conjunction with comercial alum. Methods: The pilot was placed in Isfahan Water Treatment Plant (IWTP and efficiency of these materials in removal of turbidity from raw water enters the IWTP was evaluated. The results indicated while these materials were used as coagulant aids in concentration of 1-5 mg/l conjunction with alum are able to reduced the turbidity and final residuals turbidity meets the standards limits. Results: The coagulation efficiency of these material were found to be effected by certain physico-chemical factors, namely, concentration of suspended solids, divalent cation metal and time of agitation. The relative importance of these variable was evaluated. The results of COD test proved that the natural coagulant aids in the optimum doses produce no any significant organic residual. Discussion: Economical considerations showed that using of these material as coagulant aids can cause reduction in alum consumption and in some cases are more econmical than synthetic polyelectrolyte.
Moussas, P A; Zouboulis, A I
2009-08-01
Currently, research is focused on the synthesis of new composite coagulants, which are constituted of both inorganic and organic materials. In this paper, the development of relevant reagents was investigated, by combining the inorganic pre-polymerised iron-based coagulant Polyferric Sulphate (PFS) with an organic, non-ionic polymer (Polyacrylamide, PAA) under different PAA/Fe (mg/l) and OH/Fe molar ratios. Moreover, the new reagents were characterised in terms of typical properties, stability and morphological analysis (XRD, FTIR, SEM). Their coagulation performance, when treating low or high turbid kaolin-humic acid suspensions, was also investigated, whereas the applied coagulation mechanisms were discussed by using the Photometric Dispersion Analysis (PDA) analysis. The results show that the new coagulation reagents present improved properties, including increased effective polymer species concentration, and they exhibit very good stability. The respective tests using PDA confirmed that the predominant coagulation mechanism of PFS-PAA is the bridge formation mechanism. Coagulation experiments in low or high turbid kaolin-humic acid suspensions reveal that the novel composite reagent PFS-PAA exhibits better coagulation performance, when compared with simple PFS, in terms of zeta-potential reduction, turbidity and organic matter removal and residual iron concentration.
Development of CAP code for nuclear power plant containment: Lumped model
Energy Technology Data Exchange (ETDEWEB)
Hong, Soon Joon, E-mail: sjhong90@fnctech.com [FNC Tech. Co. Ltd., Heungdeok 1 ro 13, Giheung-gu, Yongin-si, Gyeonggi-do 446-908 (Korea, Republic of); Choo, Yeon Joon; Hwang, Su Hyun; Lee, Byung Chul [FNC Tech. Co. Ltd., Heungdeok 1 ro 13, Giheung-gu, Yongin-si, Gyeonggi-do 446-908 (Korea, Republic of); Ha, Sang Jun [Central Research Institute, Korea Hydro & Nuclear Power Company, Ltd., 70, 1312-gil, Yuseong-daero, Yuseong-gu, Daejeon 305-343 (Korea, Republic of)
2015-09-15
Highlights: • State-of-art containment analysis code, CAP, has been developed. • CAP uses 3-field equations, water level oriented upwind scheme, local head model. • CAP has a function of linked calculation with reactor coolant system code. • CAP code assessments showed appropriate prediction capabilities. - Abstract: CAP (nuclear Containment Analysis Package) code has been developed in Korean nuclear society for the analysis of nuclear containment thermal hydraulic behaviors including pressure and temperature trends and hydrogen concentration. Lumped model of CAP code uses 2-phase, 3-field equations for fluid behaviors, and has appropriate constitutive equations, 1-dimensional heat conductor model, component models, trip and control models, and special process models. CAP can run in a standalone mode or a linked mode with a reactor coolant system analysis code. The linked mode enables the more realistic calculation of a containment response and is expected to be applicable to a more complicated advanced plant design calculation. CAP code assessments were carried out by gradual approaches: conceptual problems, fundamental phenomena, component and principal phenomena, experimental validation, and finally comparison with other code calculations on the base of important phenomena identifications. The assessments showed appropriate prediction capabilities of CAP.
Development of CAP code for nuclear power plant containment: Lumped model
International Nuclear Information System (INIS)
Hong, Soon Joon; Choo, Yeon Joon; Hwang, Su Hyun; Lee, Byung Chul; Ha, Sang Jun
2015-01-01
Highlights: • State-of-art containment analysis code, CAP, has been developed. • CAP uses 3-field equations, water level oriented upwind scheme, local head model. • CAP has a function of linked calculation with reactor coolant system code. • CAP code assessments showed appropriate prediction capabilities. - Abstract: CAP (nuclear Containment Analysis Package) code has been developed in Korean nuclear society for the analysis of nuclear containment thermal hydraulic behaviors including pressure and temperature trends and hydrogen concentration. Lumped model of CAP code uses 2-phase, 3-field equations for fluid behaviors, and has appropriate constitutive equations, 1-dimensional heat conductor model, component models, trip and control models, and special process models. CAP can run in a standalone mode or a linked mode with a reactor coolant system analysis code. The linked mode enables the more realistic calculation of a containment response and is expected to be applicable to a more complicated advanced plant design calculation. CAP code assessments were carried out by gradual approaches: conceptual problems, fundamental phenomena, component and principal phenomena, experimental validation, and finally comparison with other code calculations on the base of important phenomena identifications. The assessments showed appropriate prediction capabilities of CAP
Exact combinatorial approach to finite coagulating systems
Fronczak, Agata; Chmiel, Anna; Fronczak, Piotr
2018-02-01
This paper outlines an exact combinatorial approach to finite coagulating systems. In this approach, cluster sizes and time are discrete and the binary aggregation alone governs the time evolution of the systems. By considering the growth histories of all possible clusters, an exact expression is derived for the probability of a coagulating system with an arbitrary kernel being found in a given cluster configuration when monodisperse initial conditions are applied. Then this probability is used to calculate the time-dependent distribution for the number of clusters of a given size, the average number of such clusters, and that average's standard deviation. The correctness of our general expressions is proved based on the (analytical and numerical) results obtained for systems with the constant kernel. In addition, the results obtained are compared with the results arising from the solutions to the mean-field Smoluchowski coagulation equation, indicating its weak points. The paper closes with a brief discussion on the extensibility to other systems of the approach presented herein, emphasizing the issue of arbitrary initial conditions.
Vegetable coagulants as alternative for treatment of wastewater in Mexico
Directory of Open Access Journals (Sweden)
Servando López-León
2017-11-01
Full Text Available This review addresses the various properties of natural coagulants, water, the chemical substance essential for life and the ideal solvent for a large number of compounds, it is commonly used with domestic, commercial and industrial purposes. After its use, it presents sewage to be retired before use it once again. To remove pollutant, water is subject to different physical, chemical and biological processes. Here, the clarification process uses aluminum and iron materials to remove the solids present; these materials are reported as health hazardous and toxic. In Mexico, regulatory frame work stablish that treated wastewater should do not exceed 0.2 mg/L of aluminum even though has been reported an increased risk of Alzheimer's in populations when water exceeds 0.1 mg/L. Natural coagulants have showed coagulation properties when are used in the clarification process, proven its advantages over traditional ones; such as low cost, good coagulant properties and safe health and non-toxic properties. Here, we enlist some vegetable species as alternatives to the traditional based on aluminum and iron. Additionally, these species are known to have origins on Mexico or being present extensively in the territory, making possible to think about them as alternative coagulants in the clarification process of the wastewater treatment process.
Multiple roles of the coagulation protease cascade during virus infection.
Antoniak, Silvio; Mackman, Nigel
2014-04-24
The coagulation cascade is activated during viral infections. This response may be part of the host defense system to limit spread of the pathogen. However, excessive activation of the coagulation cascade can be deleterious. In fact, inhibition of the tissue factor/factor VIIa complex reduced mortality in a monkey model of Ebola hemorrhagic fever. Other studies showed that incorporation of tissue factor into the envelope of herpes simplex virus increases infection of endothelial cells and mice. Furthermore, binding of factor X to adenovirus serotype 5 enhances infection of hepatocytes but also increases the activation of the innate immune response to the virus. Coagulation proteases activate protease-activated receptors (PARs). Interestingly, we and others found that PAR1 and PAR2 modulate the immune response to viral infection. For instance, PAR1 positively regulates TLR3-dependent expression of the antiviral protein interferon β, whereas PAR2 negatively regulates expression during coxsackievirus group B infection. These studies indicate that the coagulation cascade plays multiple roles during viral infections.
Coagulation-flocculation studies of wastewaters
Leentvaar, J.
1982-01-01
Although coagulation-flocculation processes have been practiced world-wide for almost a century in water treatment, several problems both in the theoretical and in the applied field have not been resolved yet. Especially interpretation of practical results with respect to governingCosmetic wastewater treatment by coagulation and advanced oxidation processes.
Naumczyk, Jeremi; Bogacki, Jan; Marcinowski, Piotr; Kowalik, Paweł
2014-01-01
In this study, the treatment process of three cosmetic wastewater types has been investigated. Coagulation allowed to achieve chemical oxygen demand (COD) removal of 74.6%, 37.7% and 74.0% for samples A (Al2(SO4)3), B (Brentafloc F3) and C (PAX 16), respectively. The Fenton process proved to be effective as well - COD removal was equal to 75.1%, 44.7% and 68.1%, respectively. Coagulation with FeCl3 and the subsequent photo-Fenton process resulted in the best values of final COD removal equal to 92.4%, 62.8% and 90.2%. In case of the Fenton process, after coagulation these values were equal to 74.9%, 50.1% and 84.8%, while in case of the H2O2/UV process, the obtained COD removal was 83.8%, 36.2% and 80.9%. High value of COD removal in the Fenton process carried out for A and C wastewater samples was caused by a significant contribution of the final neutralization/coagulation. Very small effect of the oxidation reaction in the Fenton process in case of sample A resulting from the presence of antioxidants, 'OH radical scavengers' in the wastewater.
Treatment of melanoidin wastewater by anaerobic digestion and coagulation.
Arimi, Milton M; Zhang, Yongjun; Götz, Gesine; Geißen, Sven-Uwe
2015-01-01
Melanoidins are dark-coloured recalcitrant pollutants found in many industrial wastewaters including coffee-manufacturing effluent, molasses distillery wastewater (MDWW) and other wastewater with molasses as the raw material. The wastewaters are mostly treated with anaerobic digestion after some dilution to minimize the inhibition effect. However, the dark colour and recalcitrant dissolved organic carbon (DOC) mainly caused by melanoidin are not effectively removed. The aim of this study was to investigate the removal of colour and remnant DOC by different coagulants from anaerobically digested MDWW. From the six coagulants tested, ferric chloride had the highest melanoidin (48%), colour (92.7%) and DOC (63.3%) removal at pH 5 and a dosage of 1.6 g/l. Both polymer and inorganic salt coagulants tested had optimal colour, melanoidin and DOC removal at acidic pH. The molecular size distribution of synthetic melanoidins by liquid chromatography-organic carbon detection indicated a preferential removal of high-molecular-weight melanoidins over low weight melanoidins by the coagulation. Further studies should focus on how to improve biodegradability of the treated effluent for it to be reused as dilution water for anaerobic digestion.
Sillanpää, Mika; Ncibi, Mohamed Chaker; Matilainen, Anu; Vepsäläinen, Mikko
2018-01-01
Natural organic matter (NOM) is a complex matrix of organic substances produced in (or channeled to) aquatic ecosystems via various biological, geological and hydrological cycles. Such variability is posing a serious challenge to most water treatment technologies, especially the ones designed to treat drinking water supplies. Lately, in addition to the fluctuating composition of NOM, a substantial increase of its concentration in fresh waters, and also municipal wastewater effluents, has been reported worldwide, which justifies the urgent need to develop highly efficient and versatile water treatment processes. Coagulation is among the most applied processes for water and wastewater treatment. The application of coagulation to remove NOM from drinking water supplies has received a great deal of attention from researchers around the world because it was efficient and helped avoiding the formation of disinfection by products (DBPs). Nonetheless, with the increased fluctuation of NOM in water (concentration and composition), the efficiency of conventional coagulation was substantially reduced, hence the need to develop enhanced coagulation processes by optimizing the operating conditions (mainly the amount coagulants and pH), developing more efficient inorganic or organic coagulants, as well as coupling coagulation with other water treatment technologies. In the present review, recent research studies dealing with the application of coagulation for NOM removal from drinking water supplies are presented and compared. In addition, integration schemes combining coagulation and other water treatment processes are presented, including membrane filtration, oxidation, adsorption and others processes. Copyright © 2017 Elsevier Ltd. All rights reserved.
Review of Coagulation Technology for Removal of Arsenic: Case of Chile
Sancha, Ana María
2006-01-01
Coagulation technology has been used since 1970 in northern Chile for removing arsenic from drinking-water. This experience suggests that coagulation is an effective technology for the removal of arsenic. It is currently possible to reduce arsenic from 400 μg/L to 10 μg/L at a rate of 500 L/sec, assuming pH, oxidizing and coagulation agents are strictly controlled. The Chilean experience with the removal of arsenic demonstrates that the water matrix dictates the selection of the arsenic-remov...
Reservoir theory, groundwater transit time distributions, and lumped parameter models
International Nuclear Information System (INIS)
Etcheverry, D.; Perrochet, P.
1999-01-01
The relation between groundwater residence times and transit times is given by the reservoir theory. It allows to calculate theoretical transit time distributions in a deterministic way, analytically, or on numerical models. Two analytical solutions validates the piston flow and the exponential model for simple conceptual flow systems. A numerical solution of a hypothetical regional groundwater flow shows that lumped parameter models could be applied in some cases to large-scale, heterogeneous aquifers. (author)
Coagulation-Adsorption Hybrid Process for the Treatment of Dyes and Pigments Wastewater
Directory of Open Access Journals (Sweden)
Abdul Karim Shah
2013-10-01
Full Text Available The study aimed to improve the effectiveness of dyes and pigments wastewater treatment. Hybrid system of adsorption and coagulation was applied for the reduction of COD, color, turbidity and TSS. Activated carbon adsorbent was prepared from a waste of sugar industry boiler. It was processed through physicochemical treatment with sulfuric acid following grinding, sieving, washing and drying unit operations. Combined wastewater of dyes and pigments manufacturing plant was treated with a hybrid process of coagulation and adsorption. FeCl 3, FeSO 4and Alum coagulants were tested individually and found them less effective. It was revealed that FeCl 3 coagulation, adsorption and hybrid process reduced COD (41, 51 and 54%, Color (67, 70 and 89%, turbidity (69, 71 and 90% and TSS (82, 93 and 97% respectively. Combination of FeCl3 -SBFA (Sugarcane Bagasse Fly Ash proved 90% efficient in removal than coagulation as an individual process. 4g adsorbent dose was optimized for this hybrid process
Modelling of the Blood Coagulation Cascade in an In Vitro Flow System
DEFF Research Database (Denmark)
Andersen, Nina Marianne; Sørensen, Mads Peter; Efendiev, Messoud A.
2010-01-01
We derive a mathematical model of a part of the blood coagulation cascade set up in a perfusion experiment. Our purpose is to simulate the influence of blood flow and diffusion on the blood coagulation pathway. The resulting model consists of a system of partial differential equations taking...... and flow equations, which guarantee non negative concentrations at all times. The criteria is applied to the model of the blood coagulation cascade....
REMOVAL OF ORGANIC MATTER FROM SURFACE WATER USING COAGULANTS WITH VARIOUS BASICITY
Directory of Open Access Journals (Sweden)
Lidia Dąbrowska
2016-07-01
Full Text Available Humic substances are a natural admixture of surface water and determine the level of organic pollution of water and colour intensity. Application of coagulation process in surface water treatment allows for decrease turbidity and colour of water, as well as organic matter content. In Poland most drinking water treatment plants use aluminium sulphate as a coagulant. Research works on pre-hydrolysed coagulants, e.g. polyaluminium chlorides (general formula Aln(OHmCl3n-m are also carried out. The aim of this study was to evaluate the effectiveness of the coagulation process using polyaluminium chlorides with different basicity, in reducing the level of pollution of surface water with organic substances. Apart from the typical indicators used to evaluate the content of organic compounds, the potential for trihalomethanes formation THM-FP was also determined. The influence of the type of coagulant (low, medium, highly alkaline on the efficiency of organic compound removal, determined as total organic carbon TOC, oxidisability OXI, absorbance UV254, was stated. Under the conditions of the coagulation (pH 7.2-7.4, temperature of 19-21°C, the best results were obtained using highly alkaline polyaluminium chlorides PAX-XL19F, PAX-XL1905 and PAX-XL1910S, decrease in TOC and OXI by 43-46%, slightly worse - 40-41% using low alkaline PAX18. Using the medium alkaline coagulants PAX-XL61 and PAXX-XL69, 30-35% removal of organic matter was obtained. Despite various effects of dissolved organic carbon removal, depending on the used coagulant, THM-FP in purified water did not differ significantly and ranged from 10.0 to 10.9 mgCHCl3 m-3. It was by 37-42% lower than in surface water.
Levi, Marcel; de Jonge, Evert; van der Poll, Tom
2004-01-01
A variety of clinical conditions may cause systemic activation of coagulation, ranging from insignificant laboratory changes to severe disseminated intravascular coagulation (DIC). DIC consists of a widespread, systemic activation of coagulation, resulting in diffuse fibrin deposition in small and
Control of a local neural network by feedforward and feedback inhibition
Remme, M.W.H.; Wadman, W.J.
2004-01-01
The signal transfer of a neuronal network is shaped by the local interactions between the excitatory principal cells and the inhibitory interneurons. We investigated with a simple lumped model how feedforward and feedback inhibition in.uence the steady-state network signal transfer. We analyze how
Directory of Open Access Journals (Sweden)
L. E. Whitehouse
2004-01-01
Full Text Available This paper presents a formal method of species lumping that can be applied automatically to intermediate compounds within detailed and complex tropospheric chemical reaction schemes. The method is based on grouping species with reference to their chemical lifetimes and reactivity structures. A method for determining the forward and reverse transformations between individual and lumped compounds is developed. Preliminary application to the Leeds Master Chemical Mechanism (MCMv2.0 has led to the removal of 734 species and 1777 reactions from the scheme, with minimal degradation of accuracy across a wide range of test trajectories relevant to polluted tropospheric conditions. The lumped groups are seen to relate to groups of peroxy acyl nitrates, nitrates, carbonates, oxepins, substituted phenols, oxeacids and peracids with similar lifetimes and reaction rates with OH. In combination with other reduction techniques, such as sensitivity analysis and the application of the quasi-steady state approximation (QSSA, a reduced mechanism has been developed that contains 35% of the number of species and 40% of the number of reactions compared to the full mechanism. This has led to a speed up of a factor of 8 in terms of computer calculation time within box model simulations.
[Coagulation factor VII levels in uremic patients and theirs influence factors].
Fang, Jun; Xia, Ling-Hui; Wei, Wen-Ning; Song, Shan-Jun
2004-12-01
This study was aimed to investigate coagulation factor VII level in uremic patients with chronic renal failure and to explore theirs influence factors. The plasma levels of coagulation factor VII were detected in 30 uremic patients with chronic renal failure before and after hemodialysis for 1 month, the factor VII activity (FVII:C) was determined by one-stage coagulation method, while activated factor VII (FVIIa) was measured by one-stage coagulation method using recombinant soluble tissue factor, and factor VII antigen was detected by ELISA. The results showed that: (1) The FVIIa, FVII:C and FVIIAg levels in chronic uremic patients before hemodialysis were 4.00 +/- 0.86 microg/L, (148.5 +/- 40.4)% and (99.8 +/- 21.1)% respectively, which were significantly increased, as compared with healthy controls [2.77 +/- 1.02 microg/L, (113.1 +/- 33.0)% and (73.7 +/- 18.3)% respectively, P factor VII was positively correlated with levels of blood uria nitrogen and serum creatinine before hemodialysis but not after hemodialysis. It is concluded that the enhanced levels of coagulation factor VII in chronic uremic patients suggested abnormal activated state, herperactivity and elevated production of factor VII which correlated with renal functional injury. The abnormality of factor VII in uremia may be aggravated by hemodialysis. Coagulation factor (FVII) may be a risk factor for cardiovascular events in uremic patients who especially had been accepted long-term hemodialysis.
Karam, Ayman M.; Alsaadi, Ahmad Salem; Ghaffour, NorEddine; Laleg-Kirati, Taous-Meriem
2016-01-01
Membrane distillation (MD) is an emerging technology that has a great potential for sustainable water desalination. In order to pave the way for successful commercialization of MD-based water desalination techniques, adequate and accurate dynamical models of the process are essential. This paper presents the predictive capabilities of a lumped-parameter dynamic model for direct contact membrane distillation (DCMD) and discusses the results under wide range of steady-state and dynamic conditions. Unlike previous studies, the proposed model captures the time response of the spacial temperature distribution along the flow direction. It also directly solves for the local temperatures at the membrane interfaces, which allows to accurately model and calculate local flux values along with other intrinsic variables of great influence on the process, like the temperature polarization coefficient (TPC). The proposed model is based on energy and mass conservation principles and analogy between thermal and electrical systems. Experimental data was collected to validated the steady-state and dynamic responses of the model. The obtained results shows great agreement with the experimental data. The paper discusses the results of several simulations under various conditions to optimize the DCMD process efficiency and analyze its response. This demonstrates some potential applications of the proposed model to carry out scale up and design studies. © 2016
Karam, Ayman M.
2016-10-03
Membrane distillation (MD) is an emerging technology that has a great potential for sustainable water desalination. In order to pave the way for successful commercialization of MD-based water desalination techniques, adequate and accurate dynamical models of the process are essential. This paper presents the predictive capabilities of a lumped-parameter dynamic model for direct contact membrane distillation (DCMD) and discusses the results under wide range of steady-state and dynamic conditions. Unlike previous studies, the proposed model captures the time response of the spacial temperature distribution along the flow direction. It also directly solves for the local temperatures at the membrane interfaces, which allows to accurately model and calculate local flux values along with other intrinsic variables of great influence on the process, like the temperature polarization coefficient (TPC). The proposed model is based on energy and mass conservation principles and analogy between thermal and electrical systems. Experimental data was collected to validated the steady-state and dynamic responses of the model. The obtained results shows great agreement with the experimental data. The paper discusses the results of several simulations under various conditions to optimize the DCMD process efficiency and analyze its response. This demonstrates some potential applications of the proposed model to carry out scale up and design studies. © 2016
Energy Technology Data Exchange (ETDEWEB)
Aoki, H; Sato, H; Miura, T [Tohoku University, Sendai (Japan). Faculty of Engineering
1995-03-15
The thermal stress analysis within lump coke was studied in order to investigate macro-crack formation and deformation behavior which strongly influence heat and mass transfer in a coke oven chamber. The dilatation of plastic layer, heating rate dependence of thermophysical and mechanical properties of coal/coke, creep in the plastic and semi-coke layers, macro-crack propagation and radiative heat transfer within the macro-crack were considered in an analytical model. The macro-crack propagation was determined from the estimated crack tip stress intensity factor, K{sub I}, at the macro-crack tip compared with the plane strain fracture toughness, K{sub IC}, through the unsteady-state calculation. Calculated results on crack formation and deformation behavior of lump coke were in good agreement with experimental observations in a laboratory-scale oven chamber. The analytical model could predict micro-crack formation within the lump coke normal to the heated wall and the coke surface close to the heated wall. 12 refs., 13 figs.
Removal of total suspended solid by natural coagulant derived from cassava peel waste
Mohd-Asharuddin, S.; Othman, N.; Mohd-Zin, N. S.; Tajarudin, H. A.
2018-04-01
The present study was aimed to investigate the performance of starch derived from cassava peel waste as primary coagulant and coagulant aid. Comparable study was also conducted using commercially used aluminium sulfate (alum) as primary coagulant. A series of Jar tests were performed using raw water from Sembrong Barat water treatment plant. It was observed that coagulation test using cassava peel starch (CPS) alone had unappreciable removing ability. However, it was found that combination of alum-CPS successfully achieve up to 90.48% of total suspended solid (TSS) removal under optimized working conditions (pH 9, 7.5mg/L : 100 mg/L of alum : CPS dosage, rapid mixing of 200 rpm for 1 minute; 100 rpm for 2 minutes, slow mixing of 25 rpm for 30 minutes and 30 minutes settling time). This remarks the reduction in alum dosage up to 50% compared to coagulation test using alum alone. Therefore this finding suggesting that CPS can be considered as potential source of sustainable and effective coagulant aid for water treatment especially in developing countries.
Analysis of transient heat conduction in a PWR fuel rod by an improved lumped parameter approach
Energy Technology Data Exchange (ETDEWEB)
Dourado, Eneida Regina G. [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil); Cotta, Renato M. [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Mecanica; Jian, Su, E-mail: eneidadourado@gmail.com, E-mail: sujian@nuclear.ufrj.br, E-mail: cotta@mecanica.ufrj.br [Coordenacao de Pos-Graduacao e Pesquisa de Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil). Programa de Engenharia Nuclear
2017-07-01
This paper aims to analyze transient heat conduction in a nuclear fuel rod by an improved lumped parameter approach. One-dimensional transient heat conduction is considered, with the circumferential symmetry assumed and the axial conduction neglected. The thermal conductivity and specific heat in the fuel pellet are considered temperature dependent, while the thermophysical properties of the cladding are considered constant. Hermite approximation for integration is used to obtain the average temperature and heat flux in the radial direction. Significant improvement over the classical lumped parameter formulation has been achieved. The proposed model can be also used in dynamic analysis of PWR and nuclear power plant simulators. (author)
Analysis of transient heat conduction in a PWR fuel rod by an improved lumped parameter approach
International Nuclear Information System (INIS)
Dourado, Eneida Regina G.; Cotta, Renato M.; Jian, Su
2017-01-01
This paper aims to analyze transient heat conduction in a nuclear fuel rod by an improved lumped parameter approach. One-dimensional transient heat conduction is considered, with the circumferential symmetry assumed and the axial conduction neglected. The thermal conductivity and specific heat in the fuel pellet are considered temperature dependent, while the thermophysical properties of the cladding are considered constant. Hermite approximation for integration is used to obtain the average temperature and heat flux in the radial direction. Significant improvement over the classical lumped parameter formulation has been achieved. The proposed model can be also used in dynamic analysis of PWR and nuclear power plant simulators. (author)
Causes and consequences of coagulation activation in sepsis: an evolutionary medicine perspective.
Fiusa, Maiara Marx Luz; Carvalho-Filho, Marco Antonio; Annichino-Bizzacchi, Joyce M; De Paula, Erich V
2015-05-06
Coagulation and innate immunity have been linked together for at least 450 million years of evolution. Sepsis, one of the world's leading causes of death, is probably the condition in which this evolutionary link is more evident. However, the biological and the clinical relevance of this association have only recently gained the attention of the scientific community. During sepsis, the host response to a pathogen is invariably associated with coagulation activation. For several years, coagulation activation has been solely regarded as a mechanism of tissue damage, a concept that led to several clinical trials of anticoagulant agents for sepsis. More recently, this paradigm has been challenged by the failure of these clinical trials, and by a growing bulk of evidence supporting the concept that coagulation activation is beneficial for pathogen clearance. In this article we discuss recent basic and clinical data that point to a more balanced view of the detrimental and beneficial consequences of coagulation activation in sepsis. Reappraisal of the association between coagulation and immune activation from an evolutionary medicine perspective offers a unique opportunity to gain new insights about the pathogenesis of sepsis, paving the way to more successful approaches in both basic and clinical research in this field.
Pretreatment of wastewater: Optimal coagulant selection using Partial Order Scaling Analysis (POSA)
International Nuclear Information System (INIS)
Tzfati, Eran; Sein, Maya; Rubinov, Angelika; Raveh, Adi; Bick, Amos
2011-01-01
Jar-test is a well-known tool for chemical selection for physical-chemical wastewater treatment. Jar test results show the treatment efficiency in terms of suspended matter and organic matter removal. However, in spite of having all these results, coagulant selection is not an easy task because one coagulant can remove efficiently the suspended solids but at the same time increase the conductivity. This makes the final selection of coagulants very dependent on the relative importance assigned to each measured parameter. In this paper, the use of Partial Order Scaling Analysis (POSA) and multi-criteria decision analysis is proposed to help the selection of the coagulant and its concentration in a sequencing batch reactor (SBR). Therefore, starting from the parameters fixed by the jar-test results, these techniques will allow to weight these parameters, according to the judgments of wastewater experts, and to establish priorities among coagulants. An evaluation of two commonly used coagulation/flocculation aids (Alum and Ferric Chloride) was conducted and based on jar tests and POSA model, Ferric Chloride (100 ppm) was the best choice. The results obtained show that POSA and multi-criteria techniques are useful tools to select the optimal chemicals for the physical-technical treatment.
Directory of Open Access Journals (Sweden)
Kristina B. M. Still
2017-11-01
Full Text Available Coagulation assays currently employed are often low throughput, require specialized equipment and/or require large blood/plasma samples. This study describes the development, optimization and early application of a generic low-volume and high-throughput screening (HTS assay for coagulation activity. The assay is a time-course spectrophotometric measurement which kinetically measures the clotting profile of bovine or human plasma incubated with Ca2+ and a test compound. The HTS assay can be a valuable new tool for coagulation diagnostics in hospitals, for research in coagulation disorders, for drug discovery and for venom research. A major effect following envenomation by many venomous snakes is perturbation of blood coagulation caused by haemotoxic compounds present in the venom. These compounds, such as anticoagulants, are potential leads in drug discovery for cardiovascular diseases. The assay was implemented in an integrated analytical approach consisting of reversed-phase liquid chromatography (LC for separation of crude venom components in combination with parallel post-column coagulation screening and mass spectrometry (MS. The approach was applied for the rapid assessment and identification of profiles of haemotoxic compounds in snake venoms. Procoagulant and anticoagulant activities were correlated with accurate masses from the parallel MS measurements, facilitating the detection of peptides showing strong anticoagulant activity.
Arsenic removal by coagulation using ferric chloride and chitosan from water
Directory of Open Access Journals (Sweden)
Farid Hesami
2013-01-01
Conclusions: Chitosan as natural coagulant aid improved arsenic removal efficiency by coagulation process using FeCl 3 . This method can be used for regions with drinking water contaminated with initial arsenic concentration less than 1 000 μg/l.
Evaluation of Moringa oleifera seed as coagulation aid for treatment ...
African Journals Online (AJOL)
Laboratory tests were carried out to evaluate the potentials of Moringa oleifera seed powder as a coagulation aid for removal of suspended particles in fish culture effluent. The standard jar test was used to investigate the dosage and mixing intensity required to optimize the use of the coagulant in removing of suspended ...
[Influence of Gentiana lutea L extract on blood coagulation].
Bakuridze, A D; Nikolaev, S M; Tsagarenshvili, N T; Kurdiani, N G; Mikaia, G A
2009-01-01
The dry extract from the terrestrial parts of Gentiana Lutea was received in accordance to the developed by us general technological scheme. Study of the pharmacological influence of obtained extract on the coagulating properties of blood revealed that after its per os instillation into experimental animals the time of the formation of active thromboplastin reliably increases, while the time of thrombin and fibrinous cluster formation is shortened in comparison with those indices in the animals, that did not receive phyto-preparation, at the same time morphological appearance of the peripheral blood remains unchanged. Dry extract of terrestrial parts of Gentiana Lutea prepared in accordance to the technology recommended by us, together with widely known pharmacological effects, is characterized with new activity - influence on haemostasis. Obtained preliminary data concerning influence of the extract on coagulation of the blood request further deep studies of its mechanism. Revealed new activity of the terrestrial parts of Gentiana Lutea and the studies of the mechanism of its activity will serve in future as a basis for the recommendation of its use in new nosology. Terrestrial parts of Gentiana lutea L. are proposed as an alternative of the underground parts of the plant. Alongside with that, it is expedient to continue the studies devoted to the development of the haemostatic remedies of plant origin with systemic and local action (sponges, films, skin glues) from terrestrial parts of Gentiana lutea L.
Coagulation of sheep intestinal and prefemoral lymph.
Hanley, C A; Johnston, M G; Nelson, W
1988-06-01
We have determined the most suitable method for the automated analysis of the clotting parameters in sheep intestinal and prefemoral lymph as defined by the Activated Partial Thromboplastin Times (APTT; measure of intrinsic coagulation pathway) and the Prothrombin Times (PT; measure of extrinsic coagulation pathway). As opposed to optical density systems, the use of a Fibro-System Fibrometer was found to provide the most consistent assessment of coagulation with the endpoint being the time to fibrin strand formation. We measured APTT in sheep intestinal and prefemoral lymph of 59.78 +/- 7.69 seconds and 51.03 +/- 10.49 seconds respectively. These values were more prolonged than those obtained from sheep blood plasma but only in the case of intestinal lymph were the differences significant (p less than 0.025). Human blood APTT values were significantly less than both sheep blood (p less than 0.05) and sheep intestinal (p less than 0.001) and prefemoral lymph (p less than 0.01). PT values were found to be 21.56 +/- 1.14 seconds in intestinal and 22.00 +/- 1.88 seconds in prefemoral lymph. These values were also significantly greater than those obtained from sheep blood (both p less than 0.001). Human blood PTs were significantly less than both sheep blood (p less than 0.001) and intestinal and prefemoral lymph (both p less than 0.001). Measurement of APTT and PT values in intestinal lymph and PT determinations in prefemoral lymph were not affected by storage in the refrigerator or freezer. There was some indication that APTT values in prefemoral samples were susceptible to storage artifacts; however, the differences in coagulation times were not significant.
The lumped heat capacity method applied to target heating
Rickards, J.
2013-01-01
The temperature of metal samples was measured while they were bombarded by the beam from the a particle accelerator. The evolution of the temperature with time can be explained using the lumped heat capacity method of heat transfer. A strong dependence on the type of mounting was found. Se midió la temperatura de muestras metálicas al ser bombardeadas por el haz de iones del Acelerador Pelletron del Instituto de Física. La evolución de la temperatura con el tiempo se puede explicar usando ...
Probing lumps of wee partons in deep inelastic scattering
International Nuclear Information System (INIS)
Buchmueller, W.
1994-06-01
Recently, the ZEUS collaboration has reported on several remarkable properties of events with a large rapidity gap in deep inelastic scattering. We suggest that the mechanism underlying these events is the scattering of electrons off lumps of wee partons inside the proton. Based on an effective lagrangian approach the Q 2 -, x- and W-distributions are evaluated. For sufficiently small invariant mass of the detected hadronic system, the mechanism implies leading twist behaviour. The x- and W-distributions are determined by the Lipatov exponent which governs the behaviour of parton densities at small x. (orig.)
Lumped-parameter fuel rod model for rapid thermal transients
International Nuclear Information System (INIS)
Perkins, K.R.; Ramshaw, J.D.
1975-07-01
The thermal behavior of fuel rods during simulated accident conditions is extremely sensitive to the heat transfer coefficient which is, in turn, very sensitive to the cladding surface temperature and the fluid conditions. The development of a semianalytical, lumped-parameter fuel rod model which is intended to provide accurate calculations, in a minimum amount of computer time, of the thermal response of fuel rods during a simulated loss-of-coolant accident is described. The results show good agreement with calculations from a comprehensive fuel-rod code (FRAP-T) currently in use at Aerojet Nuclear Company
New equivalent lumped electrical circuit for piezoelectric transformers.
Gonnard, Paul; Schmitt, P M; Brissaud, Michel
2006-04-01
A new equivalent circuit is proposed for a contour-vibration-mode piezoelectric transformer (PT). It is shown that the usual lumped equivalent circuit derived from the conventional Mason approach is not accurate. The proposed circuit, built on experimental measurements, makes an explicit difference between the elastic energies stored respectively on the primary and secondary parts. The experimental and theoretical resonance frequencies with the secondary in open or short circuit are in good agreement as well as the output "voltage-current" characteristic and the optimum efficiency working point. This circuit can be extended to various PT configurations and appears to be a useful tool for modeling electronic devices that integrate piezoelectric transformers.
Low-cost multi-stage filtration enhanced by coagulation-flocculation in upflow gravel filtration
Directory of Open Access Journals (Sweden)
L. D. Sánchez
2012-12-01
Full Text Available This paper assesses the operational and design aspects of coagulation and flocculation in upflow gravel filters (CF-UGF in a multi-stage filtration (MSF plant. This study shows that CF-UGF units improve the performance of MSF considerably, when the system operates with turbidity above 30 NTU. It strongly reduces the load of particulate material before the water enters in the slow sand filters (SSF and therewith avoids short filter runs and prevents early interruption in SSF operations. The removal efficiency of turbidity in the CF-UGF with coagulant was between 85 and 96%, whereas the average efficiency without coagulant dosing was 46% (range: 21–76%. Operating with coagulant also improves the removal efficiency for total coliforms, E-coli and HPC. No reduction was observed in the microbial activity of the SSF, no obstruction of the SSF bed was demonstrated and SSF runs were maintained between 50 and 70 days for a maximum head loss of 0.70 m. The most important advantage is the flexibility of the system to operate with and without coagulant according to the influent turbidity. It was only necessary for 20% of the time to operate with the coagulant. The CF-UGF unit represented 7% of total construction costs and the O&M cost for the use of coagulant represented only 0.3%.
Amuda, O S; Amoo, I A; Ajayi, O O
2006-02-28
This study investigated the effect of coagulation/flocculation treatment process on wastewater of Fumman Beverage Industry, Ibadan, Nigeria. The study also compared different dosages of coagulant, polyelectrolyte (non-ionic polyacrylamide) and different pH values of the coagulation processes. The effect of different dosages of polyelectrolyte in combination with coagulant was also studied. The results reveal that low pH values (3-8), enhance removal efficiency of the contaminants. Percentage removal of 78, 74 and 75 of COD, TSS and TP, respectively, were achieved by the addition of 500 mg/L Fe2(SO4)3.3H2O and 93, 94 and 96% removal of COD, TSS and TP, respectively, were achieved with the addition of 25 mg/L polyelectrolyte to the coagulation process. The volume of sludge produced, when coagulant was used solely, was higher compared to the use of polyelectrolyte combined with Fe2(SO4)3.3H2O. This may be as a result of non-ionic nature of the polyelectrolyte; hence, it does not chemically react with solids of the wastewater. Coagulation/flocculation may be useful as a pre-treatment process for beverage industrial wastewater prior to biological treatment.
Inhibitory Effect of Triterpenoids from Panax ginseng on Coagulation Factor X
Directory of Open Access Journals (Sweden)
Lingxin Xiong
2017-04-01
Full Text Available Enzymes involved in the coagulation process have received great attention as potential targets for the development of oral anti-coagulants. Among these enzymes, coagulation factor Xa (FXa has remained the center of attention in the last decade. In this study, 16 ginsenosides and two sapogenins were isolated, identified and quantified. To determine the inhibitory potential on FXa, the chromogenic substrates method was used. The assay suggested that compounds 5, 13 and 18 were mainly responsible for the anti-coagulant effect. Furthermore, these three compounds also possessed high thrombin selectivity in the thrombin inhibition assay. Furthermore, Glide XP from Schrödinger was employed for molecular docking to clarify the interaction between the bioactive compounds and FXa. Therefore, the chemical and biological results indicate that compounds 5 (ginsenoside Rg2, 13 (ginsenoside Rg3 and 18 (protopanaxtriol, PPT are potential natural inhibitors against FXa.
Interpretation of coagulation test results using a web-based reporting system.
Quesada, Andres E; Jabcuga, Christine E; Nguyen, Alex; Wahed, Amer; Nedelcu, Elena; Nguyen, Andy N D
2014-01-01
Web-based synoptic reporting has been successfully integrated into diverse fields of pathology, improving efficiency and reducing typographic errors. Coagulation is a challenging field for practicing pathologists and pathologists-in-training alike. To develop a Web-based program that can expedite the generation of a individualized interpretive report for a variety of coagulation tests. We developed a Web-based synoptic reporting system composed of 119 coagulation report templates and 38 thromboelastography (TEG) report templates covering a wide range of findings. Our institution implemented this reporting system in July 2011; it is currently used by pathology residents and attending pathologists. Feedback from the users of these reports have been overwhelmingly positive. Surveys note the time saved and reduced errors. Our easily accessible, user-friendly, Web-based synoptic reporting system for coagulation is a valuable asset to our laboratory services. Copyright© by the American Society for Clinical Pathology (ASCP).
Acute lymphoblastic leukemia presenting as a breast lump: A report of two cases
Directory of Open Access Journals (Sweden)
Syed Besina
2013-01-01
Full Text Available Extra-medullary leukemic infiltration of the breast by acute lymphoblastic leukemia (ALL is very rare. We report two cases of ALL presenting as breast masses and diagnosed on fine-needle aspiration (FNA. Our first patient, a post-partum 30-year-old female, developed bilateral breast lumps in her last trimester of pregnancy and complained of easy fatigability. Our second patient, a 14-year-old girl, presented with a right-breast lump of 1-week duration. She had received treatment for ALL 1 year back and had been in complete remission for the last 1 year. FNA of the breast nodules done in both the cases revealed diffuse infiltration by lymphoblasts. Subsequent hematological investigations confirmed bone marrow involvement by ALL in the first case and extra-medullary relapse in the second case. Fine-needle aspiration cytology (FNAC is an easy and cost effective method for the early diagnosis of metastatic leukemic infiltration, avoiding unnecessary excisional biopsies in such cases.
International Nuclear Information System (INIS)
Talbert, Robert J; Holan, Scott H; Viator, John A
2007-01-01
Discriminating viable from thermally coagulated blood in a burn wound can be used to profile burn depth, thus aiding the removal of necrotic tissue. In this study, we used a two-wavelength photoacoustic imaging method to discriminate coagulated and non-coagulated blood in a dermal burn phantom. Differences in the optical absorption spectra of coagulated and non-coagulated blood produce different values of the ratio of peak photoacoustic amplitude at 543 and 633 nm. The absorption values obtained from spectroscopic measurements indicate that the ratio of photoacoustic pressure for 543 and 633 nm for non-coagulated blood was 15.7:1 and 1.6:1 for coagulated blood. Using planar blood layers, we found the photoacoustic ratios to be 13.5:1 and 1.6:1, respectively. Using the differences in the ratios of coagulated and non-coagulated blood, we propose a scheme using statistical classification analysis to identify the different blood samples. Based upon these distinctly different ratios, we identified the planar blood samples with an error rate of 0%. Using a burn phantom with cylindrical vessels containing coagulated and non-coagulated blood, we achieved an error rate of 11.4%. These results have shown that photoacoustic imaging could prove to be a valuable tool in the diagnosis of burns
The use of cold coagulation for the treatment of cervical intraepithelial neoplasia
LENUS (Irish Health Repository)
Wyse, A
2017-05-01
In 2015, Cold Coagulation was introduced as a treatment for cervical intraepithelial neoplasia (CIN) at our colposcopy clinic. We reviewed the 6-month follow up data of the first 200 women who underwent Cold Coagulation using cytology and HPV status as tests of cure (TOC). A random sample of 200 patients treated by Large Loop Excision of the Transformation Zone (LLETZ) during the same period was used to compare treatment outcome. Six months following treatment,173 (86.5%) of the women treated by CC and 167 (83.5%) treated by LLETZ had negative cytology. (x2= P>0.05). 148 (74%) treated by Cold Coagulation and 166 (83%) treated by LLETZ were HPV negative (x2= P<0.05). One hundred and thirty-nine (70%) women treated by Cold Coagulation and 152 (76%) treated with LLETZ had normal cytology and were HPV negative. This audit of our initial experience supports the observation that Cold Coagulation is as effective as LLETZ in the management of CIN when cervical cytology is used as a test of cure.
Comparison of the level of residual coagulant activity in different cheese varieties.
Bansal, Nidhi; Fox, Patrick F; McSweeney, Paul L H
2009-08-01
The coagulant retained in cheese curd is a major contributor to proteolysis during ripening. The objective of this study was to quantify residual coagulant in 9 cheese varieties by measuring its activity on a synthetic heptapeptide (Pro-Thr-Glu-Phe-[NO2-Phe]-Arg-Leu) assayed using reversed-phase HPLC. The level of residual coagulant activity was highest in Camembert cheese, probably due to its low pH at whey drainage and the high moisture content of the cheese, followed in order by Feta=Port du Salut=Cheddar>Gouda>Emmental=Parmigiano Reggiano=low-moisture part-skim Mozzarella=Mozzarella di Bufala Campana. The high cooking temperature (50-54 degrees C) used during the manufacture of Emmental and Parmigiano Reggiano cheeses and the cooking and stretching step in hot water during the manufacture of Mozzarella cheese may be the reasons for the lowest residual coagulant activity in these cheeses. The level of residual coagulant activity was higher in Feta cheese made from milk concentrated by ultrafiltration than in conventional Feta.
Hoffmann, Martin; Ulrich, Anita; Schloericke, Erik; Limmer, Stefan; Habermann, Jens Karsten; Wolken, Heike; Bruch, Hans-Peter; Kujath, Peter
2012-01-01
A technique for the safe transfer of electric energy to the pulmonary surface for the potential evaporation of malignant tumours is non-existent to date. By conducting the current study, we wanted to generate data on the potential beneficiary effects and complications of using cold-plasma coagulation on the pulmonary surface. Cold-plasma coagulation was applied to the pulmonary surface in eight female mini-pigs via a thoracoscopic access. After 12 days, we performed a re-thoracoscopy on the contralateral side. After a further 12 days, we performed a median sternotomy and did cold-plasma coagulation on previously untreated areas of either lung. No pulmonary fistulas were detected. In two of the eight pigs, we found a localized chronic pneumonia. None of the pigs died during the course of the study. Morbidity was also low with two pigs refusing food intake, one pig with dyspnoea after difficult intubation and one pig coughing. All events were self-limited and occurred only on post-operative Day 1. The treatment effect was almost linear and correlated to the generator energy applied. The differences between the effects reached statistical significance (P < 0.05). The application of cold-plasma coagulation to the pulmonary surface is safe in pigs. A potential clinical application of this technique is treatment of malignant pleural mesothelioma. PMID:22194274
Some error estimates for the lumped mass finite element method for a parabolic problem
Chatzipantelidis, P.; Lazarov, R. D.; Thomé e, V.
2012-01-01
for the standard Galerkin method carry over to the lumped mass method whereas nonsmooth initial data estimates require special assumptions on the triangulation. We also discuss the application to time discretization by the backward Euler and Crank-Nicolson methods
Characteristics of BPA removal from water by PACl-Al13 in coagulation process.
Xiaoying, Ma; Guangming, Zeng; Chang, Zhang; Zisong, Wang; Jian, Yu; Jianbing, Li; Guohe, Huang; Hongliang, Liu
2009-09-15
This paper discussed the coagulation characteristics of BPA with polyaluminum chloride (PACl-Al(13)) as coagulant, examined the impact of coagulation pH, PACl-Al(13) dosage, TOC (total organic carbon) and turbidity on BPA removal, and analyzed the possible dominant mechanisms in water coagulation process. Formation and performance of flocs during coagulation processes were monitored using photometric dispersion analyzer (PDA). When the concentration of humic acid matters and turbidity was low in the solution, the experimental results showed that the removal of BPA experienced increase and subsequently decrease with the PACl-Al(13) dosage increasing. The optimal PACl-Al(13) dosage was found at BPA/PACl-Al(13)=1:2.6(M/M) under our experiment conditions. Results show that the maximum BPA removal efficiency occurred at pH 9.0 due to the adsorption by Al(13) aggregates onto BPA rather than charge neutralization mechanism by polynuclear aluminous salts in the solution. The humic acid matters and kaolin in the solution have significant effect on BPA removal with PACl-Al(13) in the coagulation. The BPA removal will be weakened at high humic matters. The removal rate of BPA increased and subsequently decreased with the turbidity increasing.
Effects of storage conditions of Moringa oleifera seeds on its performance in coagulation.
Katayon, S; Noor, M J Megat Mohd; Asma, M; Ghani, L A Abdul; Thamer, A M; Azni, I; Ahmad, J; Khor, B C; Suleyman, A M
2006-09-01
Moringa oleifera is a plant whose seeds have coagulation properties for treating water and wastewater. In this study the coagulation efficiency of Moringa oleifera kept in different storage conditions were studied. The Moringa oleifera seeds were stored at different conditions and durations; open container and closed container at room temperature (28 degrees C) and refrigerator (3 degrees C) for durations of 1, 3 and 5 months. Comparison between turbidity removal efficiency of Moringa oleifera kept in refrigerator and room temperature revealed that there was no significant difference between them. The Moringa oleifera kept in refrigerator and room temperature for one month showed higher turbidity removal efficiency, compared to those kept for 3 and 5 months, at both containers. The coagulation efficiency of Moringa oleifera was found to be dependent on initial turbidity of water samples. Highest turbidity removals were obtained for water with very high initial turbidity. In summary coagulation efficiency of Moringa oleifera was found independent of storage temperature and container, however coagulation efficiency of Moringa oleifera decreased as storage duration increased. In addition, Moringa oleifera can be used as a potential coagulant especially for very high turbidity water.
Calvetti, Daniela; Cheng, Yougan; Somersalo, Erkki
2016-12-01
Identifying feasible steady state solutions of a brain energy metabolism model is an inverse problem that allows infinitely many solutions. The characterization of the non-uniqueness, or the uncertainty quantification of the flux balance analysis, is tantamount to identifying the degrees of freedom of the solution. The degrees of freedom of multi-compartment mathematical models for energy metabolism of a neuron-astrocyte complex may offer a key to understand the different ways in which the energetic needs of the brain are met. In this paper we study the uncertainty in the solution, using techniques of linear algebra to identify the degrees of freedom in a lumped model, and Markov chain Monte Carlo methods in its extension to a spatially distributed case. The interpretation of the degrees of freedom in metabolic terms, more specifically, glucose and oxygen partitioning, is then leveraged to derive constraints on the free parameters to guarantee that the model is energetically feasible. We demonstrate how the model can be used to estimate the stoichiometric energy needs of the cells as well as the household energy based on the measured oxidative cerebral metabolic rate of glucose and glutamate cycling. Moreover, our analysis shows that in the lumped model the net direction of lactate dehydrogenase (LDH) in the cells can be deduced from the glucose partitioning between the compartments. The extension of the lumped model to a spatially distributed multi-compartment setting that includes diffusion fluxes from capillary to tissue increases the number of degrees of freedom, requiring the use of statistical sampling techniques. The analysis of the distributed model reveals that some of the conclusions valid for the spatially lumped model, e.g., concerning the LDH activity and glucose partitioning, may no longer hold.
Energy Technology Data Exchange (ETDEWEB)
Rao, Laxminarsimha V., E-mail: laxman@iitk.ac.in [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India); Roy, Subhradeep [Department of Biomedical Engineering and Mechanics (MC 0219), Virginia Tech, 495 Old Turner Street, Blacksburg, VA 24061 (United States); Das, Sovan Lal [Mechanics and Applied Mathematics Group, Department of Mechanical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016 (India)
2017-01-15
We estimate the equilibrium size distribution of cholesterol rich micro-domains on a lipid bilayer by solving Smoluchowski equation for coagulation and fragmentation. Towards this aim, we first derive the coagulation kernels based on the diffusion behaviour of domains moving in a two dimensional membrane sheet, as this represents the reality better. We incorporate three different diffusion scenarios of domain diffusion into our coagulation kernel. Subsequently, we investigate the influence of the parameters in our model on the coagulation and fragmentation behaviour. The observed behaviours of the coagulation and fragmentation kernels are also manifested in the equilibrium domain size distribution and its first moment. Finally, considering the liquid domains diffusing in a supported lipid bilayer, we fit the equilibrium domain size distribution to a benchmark solution.
Blood coagulation and fibrinolysis of the whole-body irradiated rabbits
International Nuclear Information System (INIS)
Hishikawa-Itoh, Youko; Ayakawa, Yoshio; Miyata, Nobuki
1984-01-01
To study the effects of irradiation on blood coagulation and fibrinolysis, rabbits were irradiated with 60 Co γ-rays (whole-body: 0, 100, 400, 800, 1200 rads). Clotting time, activity of plasmin and plasminogen, and fibrinogen contents of irradiated rabbit plasma were measured at 4 days before, immediately after, and at 1, 3, 7, 10, and 14 days after irradiation. Both clotting times obtained by addition of (kaolin+phospholipid) which expressed effects on the total intrinsic coagulation system, and by addition of (Ca 2+ ) which expressed effects on the total extrinsic coagulation system, were prolonged with small dose irradiation (100 rads) immediately and 3 days after irradiation. However, with high dose irradiation (400-1200 rads), these clotting times were prolonged 1 day after irradiation. The times of manifestation of irradiation effects on clotting time were different in small and high dose irradiation. Plasmin activity was decreased immediately, 1 day after and recovered 3 days after irradiation. Plasminogen activity was markedly increased in 800 and 1200 rads irradiated groups from 3 days after irradiation. Conversion of plasminogen into plasmin was impaired by irradiation. Fibrinogen contents increased rapidly in all irradiated rabbits except for 100 rads from 1 day after irradiation. These results revealed decreased coagulation and fibrinolysis activities in rabbit blood, irradiation injury of both coagulation and fibrinolysis activation systems, and accumulation of the precursors of fibrin and plasmin (i.e., fibrinogen and plasminogen). (author)
Nanoparticles and the blood coagulation system. Part I: benefits of nanotechnology.
Ilinskaya, Anna N; Dobrovolskaia, Marina A
2013-05-01
Nanotechnology is proven to provide certain benefits in drug delivery by improving solubility, increasing uptake to target sites and changing pharmacokinetics profiles of traditional drugs. Since properties of many materials change tremendously at the nanoscale levels, nanotechnology is also being explored in various industrial applications. As such, nanoparticles are rapidly entering various areas of industry, biology and medicine. The benefits of using nanotechnology for industrial and biomedical applications are often tempered by concerns about the safety of these new materials. One such area of concern includes their effect on the immune system. While nanoparticle interactions with various constituents of the immune system have been reviewed before, little attention was given to nanoparticle effects on the blood coagulation system. Nanoparticle interface with the blood coagulation system may lead to either benefits to the host or adverse reactions. This article reviews recent advances in our understanding of nanoparticle interactions with plasma coagulation factors, platelets, endothelial cells and leukocytes. Part I is focused on desirable interactions between nanoparticles and the coagulation system, and discusses benefits of using nanotechnology to intervene in coagulation disorders. Undesirable interactions posing safety concerns are covered in part II, which will be published in the June issue of Nanomedicine.
Effect of fibrinogen on blood coagulation detected by optical coherence tomography
International Nuclear Information System (INIS)
Xu, Xiangqun; Teng, Xiangshuai
2015-01-01
Our previous work demonstrated that an optical coherence tomography (OCT) technique and the parameter 1/e light penetration depth (d 1/e ) were able to characterize the whole blood coagulation process in contrast to existing optical tests that are performed on plasma samples. To evaluate the feasibility of the technique for quantifying the effect of fibrinogen (Fbg) on blood coagulation, a dynamic study of d 1/e of blood in various Fbg concentrations was performed in static state. Two groups of blood samples of hematocrit (HCT) in 35, 45, and 55% were reconstituted of red blood cells with: 1) treated plasma with its intrinsic Fbg removed and commercial Fbg added (0–8 g L −1 ); and 2) native plasma with commercial Fbg added (0–8 g L −1 ). The results revealed a typical behavior due to coagulation induced by calcium ions and the clotting time is Fbg concentration-dependent. The clotting time was decreased by the increasing amount of Fbg in both groups. Besides, the blood of lower HCT with various levels of Fbg took shorter time to coagulate than that of higher HCT. Consequently, the OCT method is a useful and promising tool for the detection of blood-coagulation processes induced with different Fbg levels. (paper)
Chemical coagulants and Moringa oleifera seed extract for treating concrete wastewater
Directory of Open Access Journals (Sweden)
Heber Martins de Paula
2016-01-01
Full Text Available Wastewater from concrete plants has a high pH and a high concentration of suspended solids, necessitating treatment before reuse or discharge into the environment. The objective of this study is to evaluate the efficiency of two chemical coagulants, aluminum sulfate (Al2(SO43 and iron chloride (FeCl3, and a natural coagulant, Moringa oleifera (MO, all in their soluble forms, in the treatment of wastewater from concrete plants. To this end, the efficiencies of the three coagulants, in combinations with different proportions, were tested. The quality parameters of the wastewater obtained after the treatments were compared to the limit values for non-potable water. The use of coagulants in their soluble form potentiates their effect, especially when preparing the MO extract, i.e., greater amounts of the protein responsible for the coagulation is extracted. A mixture with MO and Al2(SO43 in a 20:80 proportion showed the best results, with 97.5% of the turbidity removed at 60 min. of sedimentation, allowing the treated water to be used for washing vehicles and flushing toilets. The FeCl3 treatment produced a high concentration of chlorides, which could cause corrosion problems, and is therefore not recommended for concrete wastewater treatment.
International Nuclear Information System (INIS)
Mian, Muhammad Umer; Khir, M. H. Md.; Tang, T. B.; Dennis, John Ojur; Riaz, Kashif; Iqbal, Abid; Bazaz, Shafaat A.
2015-01-01
Pre-fabrication, behavioural and performance analysis with computer aided design (CAD) tools is a common and fabrication cost effective practice. In light of this we present a simulation methodology for a dual-mass oscillator based 3 Degree of Freedom (3-DoF) MEMS gyroscope. 3-DoF Gyroscope is modeled through lumped parameter models using equivalent circuit elements. These equivalent circuits consist of elementary components which are counterpart of their respective mechanical components, used to design and fabricate 3-DoF MEMS gyroscope. Complete designing of equivalent circuit model, mathematical modeling and simulation are being presented in this paper. Behaviors of the equivalent lumped models derived for the proposed device design are simulated in MEMSPRO T-SPICE software. Simulations are carried out with the design specifications following design rules of the MetalMUMPS fabrication process. Drive mass resonant frequencies simulated by this technique are 1.59 kHz and 2.05 kHz respectively, which are close to the resonant frequencies found by the analytical formulation of the gyroscope. The lumped equivalent circuit modeling technique proved to be a time efficient modeling technique for the analysis of complex MEMS devices like 3-DoF gyroscopes. The technique proves to be an alternative approach to the complex and time consuming couple field analysis Finite Element Analysis (FEA) previously used
Energy Technology Data Exchange (ETDEWEB)
Mian, Muhammad Umer, E-mail: umermian@gmail.com; Khir, M. H. Md.; Tang, T. B. [Department of Electrical and Electronic Engineering, Universiti Teknologi PETRONAS, Tronoh, Perak (Malaysia); Dennis, John Ojur [Department of Fundamental & Applied Sciences, Universiti Teknologi PETRONAS, Tronoh, Perak (Malaysia); Riaz, Kashif; Iqbal, Abid [Faculty of Electronics Engineering, GIK Institute of Engineering Sciences and Technology, Topi, Khyber Pakhtunkhaw (Pakistan); Bazaz, Shafaat A. [Department of Computer Science, Center for Advance Studies in Engineering, Islamabad (Pakistan)
2015-07-22
Pre-fabrication, behavioural and performance analysis with computer aided design (CAD) tools is a common and fabrication cost effective practice. In light of this we present a simulation methodology for a dual-mass oscillator based 3 Degree of Freedom (3-DoF) MEMS gyroscope. 3-DoF Gyroscope is modeled through lumped parameter models using equivalent circuit elements. These equivalent circuits consist of elementary components which are counterpart of their respective mechanical components, used to design and fabricate 3-DoF MEMS gyroscope. Complete designing of equivalent circuit model, mathematical modeling and simulation are being presented in this paper. Behaviors of the equivalent lumped models derived for the proposed device design are simulated in MEMSPRO T-SPICE software. Simulations are carried out with the design specifications following design rules of the MetalMUMPS fabrication process. Drive mass resonant frequencies simulated by this technique are 1.59 kHz and 2.05 kHz respectively, which are close to the resonant frequencies found by the analytical formulation of the gyroscope. The lumped equivalent circuit modeling technique proved to be a time efficient modeling technique for the analysis of complex MEMS devices like 3-DoF gyroscopes. The technique proves to be an alternative approach to the complex and time consuming couple field analysis Finite Element Analysis (FEA) previously used.
Energy Technology Data Exchange (ETDEWEB)
Wang, Yuxia [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Duan, Jinming, E-mail: jinmingduan@xauat.edu.cn [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia); Li, Wei [Key Laboratory of Northwest Water Resources, Environment and Ecology, MOE, School of Environmental & Municipal Engineering, Xi’an University of Architecture and Technology (China); Beecham, Simon; Mulcahy, Dennis [Centre for Water Management and Reuse, School of Natural and Built Environments, University of South Australia, Mawson Lakes Campus, South Australia (Australia)
2016-02-13
Highlights: • A simultaneous UV catalysed oxidation–coagulation for As(III) removal is proposed. • As(III) was effectively oxidised to As(V) by the UV catalysed coagulation. • >99% removal for As(III) in pH 4–6 at low doses of Ti(SO{sub 4}){sub 2} was achieved. • Concurrent UV radiation in massive small crystal formation facilitate the effects. • Reaction mechanisms involve both hydroxyl radicals and superoxide radicals. - Abstract: This study explored the efficacy and efficiency of a simultaneous UV-catalyzed oxidation–coagulation process of titanium sulfate (UV/Ti(SO{sub 4}){sub 2}) for efficient removal of As(III) from water. It revealed that, As(III) could be oxidized to As(V) during the UV catalyzed coagulation of Ti(SO{sub 4}){sub 2} with highly efficient As(III) removal in the pH range 4–6{sub .} The UV catalyzed oxidation–coagulation showed surprisingly effective oxidation of As(III) to As(V) within a short time. XPS indicated that 84.7% of arsenic on the coagulated precipitate was in the oxidized form of As(V) after the UV/Ti(SO{sub 4}){sub 2} treatment of As(III) aqueous solutions at pH 5. Arsenic remaining in solution at high pH was in the oxidized form As(V). Removal efficiencies of As(III) were investigated as a function of pH, Ti(SO{sub 4}){sub 2} dosage, initial As(III) concentration and irradiation energy. As(III) could almost completely be removed (>99%) by the photocatalytic oxidation–coagulation process with a moderate dose of Ti(SO{sub 4}){sub 2} in the pH range 4–6 at an initial arsenic concentration of 200 μg/L. The mechanisms of the photocatalytic coagulation oxidation of Ti(SO{sub 4}){sub 2} are similar to those of UV/crystalline TiO{sub 2} particles, involving the formation and reactions of the hydroxyl radical OH· and superoxide HO{sub 2}·/O{sub 2}{sup ·−}.
Quinine-induced disseminated intravascular coagulation.
Spearing, R L; Hickton, C M; Sizeland, P; Hannah, A; Bailey, R R
Recurrent disseminated intravascular coagulation occurred in 3 women after ingestion of quinine tablets for cramp. All had circulating quinine-dependent antibodies to platelets and in 2 there was initial evidence of antibody consumption, with low titres that rose steeply over the next few days and remained high for many months.
Choudhary, Manisha; Neogi, Sudarsan
2017-10-01
In developing countries pond water is still widely used for drinking and household purposes, which develops higher turbidity during rainy seasons and requires a large amount of chemical coagulants, and this leads to high cost of treatment. To mitigate this, it is important to find an economical and natural coagulant to treat turbid water. The present study is focused on using a plant based component as a natural coagulant that is sustainable and environment-friendly. This work focuses on the extraction, isolation and purification of a natural coagulant from seed kernels of Moringa oleifera to enhance its turbidity removal efficiency. The determination of themolecular weight of the purified proteins was done using sodium dodecyl sulfate polyacrylamide gel electrophoresis. The active coagulant proteins were isolated using 30-60% and 60-80% saturation of ammonium sulfate. It was observed that proteins with molecular weight less than 36 kDa have superior coagulation activity. Turbidity removal efficiency of these active coagulant proteins was compared with alum. The possibility of using Moringa oleifera seeds as a natural antimicrobial agent was also investigated.
Hibiscus rosa- sinensis leaf extract as coagulant aid in leachate treatment
Awang, Nik Azimatolakma; Aziz, Hamidi Abdul
2012-12-01
Hibiscus rosa- sinensis is a biodegradable material that has remained untested for flocculating properties. The objective of this study is to examine the efficiency of coagulation-flocculation processes for the removal of color, iron (Fe3+), suspended solids, turbidity and ammonia nitrogen(NH3-N), from landfill leachate using 4,000 mg/L alum in conjunction with H. rosa- sinensis leaf extract (HBaqs). Hydroxyl (O-H) and (carboxyl) C=O functional groups along the HBaqs chain help to indulge flocculating efficiency of HBaqs via bridging. The experiments confirm the positive coagulation properties of HBaqs. The Fe3+ removal rate using 4,000 mg/L alum as sole coagulant was approximately 60 %, and increased to 100 % when 4,000 mg/L alum was mixed with 500 mg/L HBaqs. By mixing, 4,000 mg/L alum with 100-500 mg/L HBaqs, 72 % of SS was removed as compared with only 45 % reduction using 4,000 mg/L alum as sole coagulant.
Phillips, Dennis R; Clark, Kevin D
2017-01-01
The innate immune system of insects responds to wounding and pathogens by mobilizing multiple pathways that provide both systemic and localized protection. Key localized responses in hemolymph include melanization, coagulation, and hemocyte encapsulation, which synergistically seal wounds and envelop and destroy pathogens. To be effective, these pathways require a targeted deposition of their components to provide protection without compromising the host. Extensive research has identified a large number of the effectors that comprise these responses, but questions remain regarding their post-translational processing, function, and targeting. Here, we used mass spectrometry to demonstrate the integration of pathogen recognition proteins, coagulants, and melanization components into stable, high-mass, multi-functional Immune Complexes (ICs) in Bombyx mori and Aedes aegypti. Essential proteins common to both include phenoloxidases, apolipophorins, serine protease homologs, and a serine protease that promotes hemocyte recruitment through cytokine activation. Pattern recognition proteins included C-type Lectins in B. mori, while A. aegypti contained a protein homologous to Plasmodium-resistant LRIM1 from Anopheles gambiae. We also found that the B. mori IC is stabilized by extensive transglutaminase-catalyzed cross-linking of multiple components. The melanization inhibitor Egf1.0, from the parasitoid wasp Microplitis demolitor, blocked inclusion of specific components into the IC and also inhibited transglutaminase activity. Our results show how coagulants, melanization components, and hemocytes can be recruited to a wound surface or pathogen, provide insight into the mechanism by which a parasitoid evades this immune response, and suggest that insects as diverse as Lepidoptera and Diptera utilize similar defensive mechanisms.
Directory of Open Access Journals (Sweden)
Sibartie Sheena
2018-01-01
Full Text Available Pharmaceutical wastewater is one of the most difficult wastewater to treat due to the presence of pharmaceutical compounds resulting in high concentration of organic matter, high turbidity and Chemical Oxygen Demand (COD. Chemical-based coagulation is a common method used to treat wastewater. However, the issue that has been raised with the use of chemical coagulants is their presence in water after treatment that can cause risks to the human health such as Alzheimer and cancer. Natural coagulants can be used as a safe alternative to these chemicals instead. Therefore, the objective of this experiment was to study the effect of H. Sabdariffa and J. Curcas as natural coagulants, separately and as a combination, on the treatment of pharmaceutical wastewater. Jar test experiment were carried out where beakers of 0.5L wastewater were mixed with the coagulants. The pH of the wastewater was varied from 2 to 12 while the coagulant dosage was varied from 40 to 200 mg/L. It was found that H. Sabdariffa works best at pH 4 and at a coagulant dosage of 190 mg/L with a highest turbidity removal of 35.8% and a decrease of COD by 29%. J. Curcas was found to perform best at pH 3 and with a coagulant dosage of 200 mg/L with a highest turbidity removal of 51% and a decrease of COD by 32%. When J. Curcas and H. Sabdariffa were used in combination, the optimum composition was found to be 80% J. Curcas and 20% H. Sabdariffa by weight with a maximum turbidity removal of 46.8% and a decrease in COD by 46%. In comparison between the two natural coagulants, J. Curcas is found to be a better and more suited coagulative agent for the treatment of pharmaceutical wastewater. The same experiment was carried with alum at pH 6 and coagulant dosage of 750 mg/L and a turbidity removal of 48% and a decrease in COD by 38% were recorded. In comparison with alum, J. Curcas was a better coagulant in treating the pharmaceutical wastewater. This shows that natural coagulants can be
Exact results for the Boltzmann equation and Smoluchowski's coagulation equation
International Nuclear Information System (INIS)
Hendriks, E.M.
1983-01-01
Almost no analytical solutions have been found for realistic intermolecular forces, largely due to the complicated structure of the collision term which calls for the construction of simplified models, in which as many physical properties are maintained as possible. In the first three chapters of this thesis such model Boltzmann equations are studied. Only spatially homogeneous gases with isotropic distribution functions are considered. Chapter I considers transition kernels, chapter II persistent scattering models and chapter III very hard particles. The second part of this dissertation deals with Smoluchowski's coagulation equation for the size distribution function in a coagulating system, with chapters devoted to the following topics: kinetics of gelation and universality, coagulation equations with gelation and exactly soluble models of nucleation. (Auth./C.F.)
Disseminated intravascular coagulation in solid tumors
International Nuclear Information System (INIS)
Terzieff, V.; Alonso, I.; Vázquez, A.
2004-01-01
It is estimated that 20-25% of cases of disseminated intravascular coagulation (DIC) relate to an underlying neoplasia primarily hematologic. It is estimated that about 5% of patients with solid tumors have CID clinic, although the incidence of subclinical alterations is much higher. The CID is not limited to the activation of the coagulation cascade, which leads to bleeding micro thrombosis and consumption of coagulation factors. Solid tumors are frequently associated adenocarcinomas producers mucin (especially gastric), usually in the context of a disseminated disease. The mucin may act as a promoter of the cascade, but probably it is a multi-event. High levels of TNF to produced by the tumor mass and chemotherapy-induced cell lysis have Also linked. Although the bleeding is usually oriented diagnosis, the most frequent cause of death is thrombosis. There are no specific tests for diagnosis. Elevated levels of D-dimer and products oriented fibrinogen degradation diagnosis. No reduction fibrinogen and almost always, one thrombocytopenia consumption. Treatment is complex and there is no consensus on many points. To recover the lost factors for consumption, it is recommended to use fresh frozen plasma and / or washed red blood cells. the heparin anticoagulation low dose is indicated since the disease causal can not be controlled quickly, but should not be initiated if there thrombocytopenia 50.000.El under profuse bleeding can require the use of tranexamic acid or EACA. Acute DIC, the case of our patient, is rare and very serious
Meng, Luming; Sheong, Fu Kit; Zeng, Xiangze; Zhu, Lizhe; Huang, Xuhui
2017-07-01
Constructing Markov state models from large-scale molecular dynamics simulation trajectories is a promising approach to dissect the kinetic mechanisms of complex chemical and biological processes. Combined with transition path theory, Markov state models can be applied to identify all pathways connecting any conformational states of interest. However, the identified pathways can be too complex to comprehend, especially for multi-body processes where numerous parallel pathways with comparable flux probability often coexist. Here, we have developed a path lumping method to group these parallel pathways into metastable path channels for analysis. We define the similarity between two pathways as the intercrossing flux between them and then apply the spectral clustering algorithm to lump these pathways into groups. We demonstrate the power of our method by applying it to two systems: a 2D-potential consisting of four metastable energy channels and the hydrophobic collapse process of two hydrophobic molecules. In both cases, our algorithm successfully reveals the metastable path channels. We expect this path lumping algorithm to be a promising tool for revealing unprecedented insights into the kinetic mechanisms of complex multi-body processes.
Narayan, Sumit; Goel, Sudha
2011-01-01
The objective of this study was to determine optimum coagulant doses for turbidity and Total Organic Carbon (TOC) removal and evaluate the extent to which TOC can be removed by enhanced coagulation. Jar tests were conducted in the laboratory to determine optimum doses of alum for the removal of turbidity and Natural Organic Matter (NOM) from river water. Various other water quality parameters were measured before and after thejar tests and included: UV Absorbance (UVA) at 254 nm, microbial concentrations, TDS, conductivity, hardness, alkalinity, and pH. The optimum alum dose for removal of turbidity and TOC was 20 mg/L for the sample collected in November 2009 and 100 mg/L for the sample collected in March 2010. In both cases, the dose for enhanced coagulation was significantly higher than that for conventional coagulation. The gain in TOC removal was insignificant compared to the increase in coagulant dose required. This is usual for low TOC (TOC need to be tested to demonstrate the effectiveness of enhanced coagulation.
A simple purification and activity assay of the coagulant protein from Moringa oleifera seed.
Ghebremichael, Kebreab A; Gunaratna, K R; Henriksson, Hongbin; Brumer, Harry; Dalhammar, Gunnel
2005-06-01
Use of extracts from Moringa oleifera (MO) is of great interest for low-cost water treatment. This paper discusses water and salt extraction of a coagulant protein from the seed, purification using ion exchange, its chemical characteristics, coagulation and antimicrobial properties. The coagulant from both extracts is a cationic protein with pI greater than 9.6 and molecular mass less than 6.5 kDa. Mass spectrometric analysis of the purified water extract indicated that it contained at least four homologous proteins, based on MS/MS peptide sequence data. The protein is thermoresistant and remained active after 5h heat treatment at 95 degrees C. The coagulant protein showed both flocculating and antibacterial effects of 1.1--4 log reduction. With samples of high turbidity, the MO extract showed similar coagulation activity as alum. Cecropin A and MO extract were found to have similar flocculation effects for clay and microorganisms. Simple methods for both the purification and assay of MO coagulating proteins are presented, which are necessary for large-scale water treatment applications.
Daniele, C. J.; Lorenzo, C. F.
1979-01-01
Lumped volume dynamic equations are derived using an energy-state formulation. This technique requires that kinetic and potential energy state functions be written for the physical system being investigated. To account for losses in the system, a Rayleigh dissipation function is also formed. Using these functions, a Lagrangian is formed and using Lagrange's equation, the equations of motion for the system are derived. The results of the application of this technique to a lumped volume are used to derive a model for the free-piston Stirling engine. The model was simplified and programmed on an analog computer. Results are given comparing the model response with experimental data.
A Size Reduction Technique for Mobile Phone PIFA Antennas Using Lumped Inductors
DEFF Research Database (Denmark)
Thaysen, Jesper; Jakobsen, Kaj Bjarne
2005-01-01
A size reduction technique for the planar inverted-F antenna (PIFA) is presented. An 18 nH lumped inductor is used in addition to a small 0.3 cm3 PIFA. The PIFA is located on dielectric foam, 5 mm above a 40 mm × 100 mm ground plane. It is possible to reduce the center frequency (|S11|min) by 33 ...
Blood coagulation in lead poisoning and the influence of specific treatment
Energy Technology Data Exchange (ETDEWEB)
Levantovskaya, O M; Lyubcenko, P N; Dayhin, I S; Sorkina, N S
1974-07-01
Results of blood coagulation studies in 104 workers with long-term exposure in a storage-battery plant. Over-all coagulation activity is unchanged in cases of mild lead poisoning, but long-term exposure gives rise to increased fibrinogen levels, activated fibrinolysis, and reduced serum accelerator globulin and prothrombin activities. 13 workers were given D-penicillamine (oral doses of 450 mg daily). All coagulation indices had become normal after 10 days' treatment. The changes observed are thought to be due to protein synthesis disturbances in the liver and to inhibition of enzymes by lead which combines with their sulfhydryl and disulfide groups. (CIS Abstr. Vol. 2)
Hommes, DW; van Dullemen, HM; Levi, M; Van der Ende, A; Woody, J; Tytgat, GNJ; van Deventer, SJH
1997-01-01
Crohn's disease has frequently been associated with coagulation abnormalities, causing intravascular deposition of fibrin and local infarction which can subsequently compromise the gut mucosa. Also, arterial and venous thromboembolic complications of larger vessels appear to be associated with
Removal of chemical oxygen demand from textile wastewater using a natural coagulant
Energy Technology Data Exchange (ETDEWEB)
Ramavandi, Bahman [Bushehr University of Medical Sciences, Bushehr (Iran, Islamic Republic of); Farjadfard, Sima [Islamic Azad University, Tehran (Iran, Islamic Republic of)
2014-01-15
A biomaterial was successfully synthesized from Plantago ovata by using an FeCl{sub 3}-induced crude extract (FCE). The potential of FCE to act as a natural coagulant was tested for the pretreatment of real textile wastewater. Tests were performed to evaluate the effects of FCE quantity, salt concentration, and wastewater pH on chemical oxygen demand (COD) reduction during a coagulation/flocculation process. Experimental results indicated that the wastewater could be effectively treated by using a coagulation/flocculation process, where the BOD{sub 5}/COD ratio of the effluent was improved to 0.48. A low coagulant dose, 1.5mg/L, achieved a high COD removal percentage, 89%, at operational conditions of neutral pH and room temperature. The experimental data revealed that the maximum COD removal occurred at water pH<8. Increasing the salt promoted the COD removal. The settling and filterability characteristics of the sludge were also studied. Scanning electron microscopy and energy dispersive spectroscopy studies were conducted to determine the sludge structure and composition, respectively. Overall, FCE as an eco-friendly biomaterial was revealed to be a very efficient coagulant and a promising option for the removal of COD from wastewaters.
Reincarnation of ancient links between coagulation and complement.
Conway, E M
2015-06-01
Throughout evolution, organisms have developed means to contain wounds by simultaneously limiting bleeding and eliminating pathogens and damaged host cells via the recruitment of innate defense mechanisms. Disease emerges when there is unchecked activation of innate immune and/or coagulation responses. A key component of innate immunity is the complement system. Concurrent excess activation of coagulation and complement - two major blood-borne proteolytic pathways - is evident in numerous diseases, including atherosclerosis, diabetes, venous thromboembolic disease, thrombotic microangiopathies, arthritis, cancer, and infectious diseases. Delineating the cross-talk between these two cascades will uncover novel therapeutic insights. © 2015 International Society on Thrombosis and Haemostasis.
Surface Potential and Particle Size Effect on the Rate of Perikinetic Coagulation
International Nuclear Information System (INIS)
Molina-Bolivar, J. A.; Galisteo-Gonzalez, F.; Cabrerizo-Vilchez, M.; Hidalgo-alvarez, R.
1998-01-01
The diffusion-controlled rapid coagulation rate of monodisperse polystyrene particles in aqueous solutions has been measured with a low angle scattering apparatus (nephelometer). We have refined this technique by using a narrow scattering flow cell and a pneumatic addicting-mixing device to introduce the salt solution and the latex sample in the cell. Coagulation rate constants were determined from analysis of the scattered light intensity dependence with time at an angle of 4.5 degree centigrade ± 1 degree centigrade. Experiments were designed to check the effects of particle size, surface potential and counterion valency on rapid coagulation constant. The particle ranged in diameter from 151 nm to 530 nm. The results are compared with the predictions of Smoluchowski's theory. Experiments to obtain the stability diagrams and the critical coagulation concentration of latexes have been performed. (Author) 31 refs
Sánchez-Martín, J; Ghebremichael, K; Beltrán-Heredia, J
2010-08-01
The coagulant proteins from Moringa oleifera purified with single-step and two-step ion-exchange processes were used for the coagulation of surface water from Meuse river in The Netherlands. The performances of the two purified coagulants and the crude extract were assessed in terms of turbidity and DOC removal. The results indicated that the optimum dosage of the single-step purified coagulant was more than two times higher compared to the two-step purified coagulant in terms of turbidity removal. And the residual DOC in the two-step purified coagulant was lower than in single-step purified coagulant or crude extract. (c) 2010 Elsevier Ltd. All rights reserved.
Performance of alum and assorted coagulants in turbidity removal of muddy water
Malik, Qasim H.
2018-03-01
Coagulation is a primary and cost effective process in water treatment plants. Under optimum conditions, not only it effectively removes turbidity but also results in reduced sludge volume and subsequently minimizes sludge management costs. Highly turbid water from streams, canals, rivers and rain run offs was run through jar test for turbidity removal. The brown water with 250NTU turbidity when coagulated with alum and assorted coagulants proved that maximum turbidity removal was witnessed using alum dose of 0.25 g/l at ph 6 with a sedimentation time of 30 min.
Early markers of blood coagulation and fibrinolysis activation in Argentine hemorrhagic fever
Heller, M. V.; Marta, R. F.; Sturk, A.; Maiztegui, J. I.; Hack, C. E.; Cate, J. W.; Molinas, F. C.
1995-01-01
Junin virus, an arenaviridae, is the etiological agent of Argentine hemorrhagic fever. In addition to thrombocytopenia, patients present several alterations in both the blood coagulation and the fibrinolytic system, but diffuse intravascular coagulation could not be demonstrated. To investigate
Le Gall, Sylvain M; Szabo, Roman; Lee, Melody; Kirchhofer, Daniel; Craik, Charles S; Bugge, Thomas H; Camerer, Eric
2016-06-23
The coagulation cascade is designed to sense tissue injury by physical separation of the membrane-anchored cofactor tissue factor (TF) from inactive precursors of coagulation proteases circulating in plasma. Once TF on epithelial and other extravascular cells is exposed to plasma, sequential activation of coagulation proteases coordinates hemostasis and contributes to host defense and tissue repair. Membrane-anchored serine proteases (MASPs) play critical roles in the development and homeostasis of epithelial barrier tissues; how MASPs are activated in mature epithelia is unknown. We here report that proteases of the extrinsic pathway of blood coagulation transactivate the MASP matriptase, thus connecting coagulation initiation to epithelial proteolysis and signaling. Exposure of TF-expressing cells to factors (F) VIIa and Xa triggered the conversion of latent pro-matriptase to an active protease, which in turn cleaved the pericellular substrates protease-activated receptor-2 (PAR2) and pro-urokinase. An activation pathway-selective PAR2 mutant resistant to direct cleavage by TF:FVIIa and FXa was activated by these proteases when cells co-expressed pro-matriptase, and matriptase transactivation was necessary for efficient cleavage and activation of wild-type PAR2 by physiological concentrations of TF:FVIIa and FXa. The coagulation initiation complex induced rapid and prolonged enhancement of the barrier function of epithelial monolayers that was dependent on matriptase transactivation and PAR2 signaling. These observations suggest that the coagulation cascade engages matriptase to help coordinate epithelial defense and repair programs after injury or infection, and that matriptase may contribute to TF-driven pathogenesis in cancer and inflammation.
An assessment of the utility of unselected coagulation screening in general hospital practice.
LENUS (Irish Health Repository)
McHugh, Johnny
2011-03-01
Coagulation screening using prothrombin time (PT) and activated partial thromboplastin time (APTT) is widely used. We performed an audit of coagulation screening in an Irish teaching hospital. We analysed PT and\\/or APTT results received during normal working hours during a 1-week period in our hospital. Abnormal results due to anticoagulants were excluded from further study. In samples with PT longer than 15.5 s and\\/or APTT longer than 42 s, we proceeded to 1: 1 mixing studies if the PT was prolonged and 1: 1 mixing studies, factor XII assay and lupus screen if the APTT was prolonged. We also obtained referral source for all samples and clinical details for abnormal samples. Six hundred and seventy-one coagulation requests were received during the study period. Three hundred and eighteen of 671 (47.4%) coagulation requests were for monitoring of anticoagulation. Three hundred and fifty-three of 671 (52.6%) requests were for coagulation screening rather than anticoagulant monitoring. In the coagulation screens received, PT was prolonged in 19 of 353 (5.4%). PT was longer than 20 s in four of 353 cases (1.1%). APTT was prolonged in 19 of 353 (5.4%). APTT was longer than 50 s in four of 353 (1.1%). No patients with abnormal PT or APTT had any bleeding sequelae during the study period. Unregulated coagulation screening has a low yield of abnormal results; the majority of these abnormal results show mild prolongation of PT or APTT with no evidence that they are associated with an increased bleeding risk.
Development of a magnetic coagulant based on Moringa oleifera seed extract for water treatment.
Santos, Tássia R T; Silva, Marcela F; Nishi, Leticia; Vieira, Angélica M S; Fagundes-Klen, Márcia R; Andrade, Murilo B; Vieira, Marcelo F; Bergamasco, Rosângela
2016-04-01
In this work, to evaluate the effectiveness of the coagulation/flocculation using a natural coagulant, using Moringa oleifera Lam functionalized with magnetic iron oxide nanoparticles, producing flakes that are attracted by an external magnetic field, thereby allowing a fast settling and separation of the clarified liquid, is proposed. The removal efficiency of the parameters, apparent color, turbidity, and compounds with UV254nm absorption, was evaluated. The magnetic functionalized M. oleifera Lam coagulant could effectively remove 90 % of turbidity, 85 % of apparent color, and 50 % for the compounds with absorption at UV254nm, in surface waters under the influence of an external magnetic field within 30 min. It was found that the coagulation/flocculation treatment using magnetic functionalized M. oleifera Lam coagulant was able to reduce the values of the physico-chemical parameters evaluated with reduced settling time.
Directory of Open Access Journals (Sweden)
Baijun Liu
2016-02-01
Full Text Available Particle coagulation is a facile approach to produce large-scale polymer latex particles. This approach has been widely used in academic and industrial research owing to its higher polymerization rate and one-step polymerization process. Our work was motivated to control the extent (or time of particle coagulation. Depending on reaction parameters, particle coagulation is also able to produce narrowly dispersed latex particles. In this study, a series of experiments were performed to investigate the role of the initiator system in determining particle coagulation and particle size distribution. Under the optimal initiation conditions, such as cationic initiator systems or higher reaction temperature, the time of particle coagulation would be advanced to particle nucleation period, leading to the narrowly dispersed polymer latex particles. By using a combination of the Smoluchowski equation and the electrostatic stability theory, the relationship between the particle size distribution and particle coagulation was established: the earlier the particle coagulation, the narrower the particle size distribution, while the larger the extent of particle coagulation, the larger the average particle size. Combined with the results of previous studies, a systematic method controlling the particle size distribution in the presence of particle coagulation was developed.
Bedekar, Priyanka A; Bhalkar, Bhumika N; Patil, Swapnil M; Govindwar, Sanjay P
2016-10-01
Generation of secondary sludge is a major concern of textile dye removal by coagulation process. Combinatorial coagulation-biodegradation treatment system has been found efficient in degradation of coagulated textile dye sludge. Moringa oleifera seed powder (700 mg L -1 ) was able to coagulate textile dyestuff from real textile wastewater with 98 % color removal. Novel consortium-BBA was found to decolorize coagulated dye sludge. Parameters that significantly affect coagulation process were optimized using response surface methodology. The bench-scale stirred tank reactor (50-L capacity) designed with optimized parameters for coagulation process could efficiently remove 98, 89, 78, and 67 % of American Dye Manufacturer's Institute (ADMI) in four repetitive cycles, respectively. Solid-state fermentation composting reactor designed to treat coagulated dye sludge showed 96 % removal of dye within 10 days. Coagulation of dyes from textile wastewater and degradation of coagulated dye sludge were confirmed by Fourier transform infrared spectroscopy (FTIR) analysis. Cell morphology assay, comet assay, and phytotoxicity confirmed the formation of less toxic products after coagulation and degradation mechanism.
Butler, Erick B.; Hung, Yung-Tse; Mulamba, Oliver
2017-09-01
This study assessed the efficiency of electrocoagulation (ECF) coupled with an addition of chemical coagulant to decolorize textile dye. Tests were conducted using Box Behnken methodology to vary six parameters: dye type, weight, coagulant type, dose, initial pH and current density. The combination of electrocoagulation and chemical coagulation was able to decolorize dye up to 99.42 % in 30 min of treatment time which is remarkably shorter in comparison with using conventional chemical coagulation. High color removal was found to be contingent upon the dye type and current density, along with the interactions between the current density and the coagulant dose. The addition of chemical coagulants did enhanced treatment efficiency.
Chronic sleep deprivation markedly reduces coagulation factor VII expression
Pinotti, Mirko; Bertolucci, Cristiano; Frigato, Elena; Branchini, Alessio; Cavallari, Nicola; Baba, Kenkichi; Contreras-Alcantara, Susana; Ehlen, J. Christopher; Bernardi, Francesco; Paul, Ketema N.; Tosini, Gianluca
2010-01-01
Chronic sleep loss, a common feature of human life in industrialized countries, is associated to cardiovascular disorders. Variations in functional parameters of coagulation might contribute to explain this relationship. By exploiting the mouse model and a specifically designed protocol, we demonstrated that seven days of partial sleep deprivation significantly decreases (−30.5%) the thrombin generation potential in plasma evaluated upon extrinsic (TF/FVIIa pathway) but not intrinsic activation of coagulation. This variation was consistent with a decrease (−49.8%) in the plasma activity levels of factor VII (FVII), the crucial physiologicalal trigger of coagulation, which was even more pronounced at the liver mRNA level (−85.7%). The recovery in normal sleep conditions for three days completely restored thrombin generation and FVII activity in plasma. For the first time, we demonstrate that chronic sleep deprivation on its own reduces, in a reversible manner, the FVII expression levels, thus influencing the TF/FVIIa activation pathway efficiency. PMID:20418241
Ventricular metastasis resulting in disseminated intravascular coagulation
Directory of Open Access Journals (Sweden)
Davis Ian D
2005-05-01
Full Text Available Abstract Background Disseminated Intravascular Coagulation (DIC complicates up to 7% of malignancies, the commonest solid organ association being adenocarcinoma. Transitional Cell Carcinoma (TCC has rarely been associated with DIC. Case presentation A 74-year-old woman with TCC bladder and DIC was found to have a cardiac lesion suspicious for metastatic disease. The DIC improved with infusion of plasma and administration of Vitamin K, however the cardiac lesion was deemed inoperable and chemotherapy inappropriate; given the patients functional status. We postulate that direct activation of the coagulation cascade by the intraventricular metastasis probably triggered the coagulopathy in this patient. Conclusion Cardiac metastases should be considered in cancer patients with otherwise unexplained DIC. This may influence treatment choices.
EFFECTIVENESS OF CHITOSAN AS NATURAL COAGULANT AID IN TREATING TURBID WATERS
Directory of Open Access Journals (Sweden)
B. Bina ، M. H. Mehdinejad ، M. Nikaeen ، H. Movahedian Attar
2009-10-01
Full Text Available During the last decade, there has been a concern about the relation between aluminum residuals in treated water and Alzheimer disease, and more interest has been considered on the development of natural coagulants such as chitosan. Chitosan, a natural linear biopolyaminosaccharide, is obtained by alkaline deacetylation of chitin. The present study was aimed to investigate the effects of alum as coagulant in conjunction with chitosan as coagulant aid on the removal of turbidity, hardness and Escherichia coli from water. A conventional jar test apparatus was employed for the tests. The optimum pH was observed between 7 to 7.5 for all turbidities. The optimum doses of alum and chitosan when used in conjunction, were 10mg/L and 1mg/L, 5mg/L and 0.5mg/L, and 5mg/L and 0.5mg/L in low, medium and high turbidities, respectively. Turbidity removal efficiency was resulted between %74.3 to %98.2 by alum in conjunction with chitosan. Residual Al+3 in treated water was less than 0.2 mg/L, meeting the international guidelines. The results showed that turbidity decrease provided also a primary Escherichia coli reduction of 2-4 log units within the first 1 to 2 hr of treatment. Hardness removal efficiency decreased when the total hardness increased from 102 to 476mg/L as CaCO3. At low initial turbidity, chitosan showed marginally better performance on hardness, especially at the ranges of 100 to 210 mg/L as CaCO3. In conclusion, coagulant aid showed a useful method for coagulation process. By using natural coagulants, considerable savings in chemicals and sludge handling cost may be achieved.
Self-production of tissue factor-coagulation factor VII complex by ovarian cancer cells
Yokota, N; Koizume, S; Miyagi, E; Hirahara, F; Nakamura, Y; Kikuchi, K; Ruf, W; Sakuma, Y; Tsuchiya, E; Miyagi, Y
2009-01-01
Background: Thromboembolic events are a major complication in ovarian cancer patients. Tissue factor (TF) is frequently overexpressed in ovarian cancer tissue and correlates with intravascular thrombosis. TF binds to coagulation factor VII (fVII), changing it to its active form, fVIIa. This leads to activation of the extrinsic coagulation cascade. fVII is produced by the liver and believed to be supplied from blood plasma at the site of coagulation. However, we recently showed that ovarian ca...
Identification of coagulation gene 3′UTR variants that are potentially regulated by microRNAs
Vossen, Carla Y.; van Hylckama Vlieg, Astrid; Teruel-Montoya, Raúl; Salloum-Asfar, Salam; de Haan, Hugoline G.; Corral, Javier; Reitsma, Pieter H.; Koeleman, Bobby P.C.; Martínez, Constantino
2017-01-01
MicroRNAs have been recognized as critical regulators of gene expression and might affect the risk of venous thrombosis. We aimed to identify 3′ untranslated region (UTR) variants in coagulation genes that influence coagulation factor levels and venous thrombosis risk. The 3′UTR of coagulation genes
The hydrophilic/hydrophobic ratio vs. dissolved organics removal by coagulation – A review
Directory of Open Access Journals (Sweden)
Djamel Ghernaout
2014-07-01
Full Text Available This review discusses the hydrophilic/hydrophobic ratio as a function of the hydrophilic and hydrophobic contents removal by coagulation process. It is well established that coagulation process could bring a reduction in dissolved organic carbon of around 30–60% by increasing the coagulant dose and optimising reaction pH, in which large organic molecules with hydrophobic property was removed preferentially. Furthermore, the literature affirmed that the greater removal of UV-absorbing substances indicates that alum coagulation preferentially removed the hydrophobic fraction of the total organic carbon. For the hydrophobic fraction, it needs to be removed entirely without its transformation into hydrophilic fractions by coagulation process avoiding pre-chlorination/pre-oxidation due to the risk of organic molecules fragmentation. Determining the exact numerical values of the hydrophilic/hydrophobic ratio for raw water and treated water at different stages of the treatment processes in a water treatment plant, as for the DCO/DBO5 ratio in the case of wastewater treatment, would help on more focusing on OM control and removal.
Study on Coagulant Dosing Control System of Micro Vortex Water Treatment
Fengping, Hu; Qi, Fan; Wenjie, Hu; Xizhen, He; Hongling, Dai
2018-03-01
In view of the characteristics of nonlinearity, large time delay and multi disturbance in the process of coagulant dosing in water treatment, it is difficult to control the dosage of coagulant. According to the four indexes of raw water quality parameters (raw water flow, turbidity, pH value) and turbidity of sedimentation tank, the micro vortex coagulation dosing control model is constructed based on BP neural network and GA. The forecast results of BP neural network model are ideal, and after the optimization of GA, the prediction accuracy of the model is partly improved. The prediction error of the optimized network is ±0.5 mg/L, and has a better performance than non-optimized network.
People are often exposed to complex mixtures of environmental chemicals such as gasoline, tobacco smoke, water contaminants, or food additives. However, investigators have often considered complex mixtures as one lumped entity. Valuable information can be obtained from these exp...
Blood viscosity during coagulation at different shear rates
Ranucci, Marco; Laddomada, Tommaso; Ranucci, Matteo; Baryshnikova, Ekaterina
2014-01-01
Abstract During the coagulation process, blood changes from a liquid to a solid gel phase. These changes are reflected by changes in blood viscosity; however, blood viscosity at different shear rates (SR) has not been previously explored during the coagulation process. In this study, we investigated the viscosity changes of whole blood in 10 subjects with a normal coagulation profile, using a cone‐on‐plate viscosimeter. For each subject, three consecutive measurements were performed, at a SR of 20, 40, 80 sec−1. On the basis of the time‐dependent changes in blood viscosity, we identified the gel point (GP), the time‐to‐gel point (TGP), the maximum clot viscosity (MCV), and the clot lysis half‐time (CLH). The TGP significantly (P = 0.0023) shortened for increasing SR, and was significantly associated with the activated partial thromboplastin time at a SR of 20 sec−1 (P = 0.038) and 80 sec−1 (P = 0.019). The MCV was significantly lower at a SR of 80 sec−1 versus 40 sec−1 (P = 0.027) and the CLH significantly (P = 0.048) increased for increasing SR. These results demonstrate that measurement of blood viscosity during the coagulation process offers a number of potentially useful parameters. In particular, the association between the TGP and the activated partial thromboplastin time is an expression of the clotting time (intrinsic and common pathway), and its shortening for increasing SR may be interpreted the well‐known activating effects of SR on platelet activation and thrombin generation. Further studies focused on the TGP under conditions of hypo‐ or hypercoagulability are required to confirm its role in the clinical practice. PMID:24994896
Directory of Open Access Journals (Sweden)
Mohini Verma
2018-04-01
Full Text Available Landfill leachate and municipal wastewater at various ratios (1:20, 1:10, 1:7 and 1:5 were subjected to coagulation and electrocoagulation (EC. Alum was used in conventional coagulation at pH 6 and aluminum plate as electrode was used in EC at a current density of 386 A/m2 with 5 cm inter electrode spacing. Treatment efficiency was assessed from removal of chemical oxygen demand (COD, total suspended solids (TSS, turbidity, ammonia, nitrate and phosphate. At 1:5 ratio of landfill leachate to municipal wastewater, highest COD removal was with 3.8 g/L alum whereas highest turbidity removal was with 3.3 g/L alum during coagulation. EC exhibited almost similar removal efficiency for all the parameters at different ratios tested except for COD which was considerably higher at 1:20 ratio. Aluminum consumption from electrode was 0.7 g/L following EC as compared to 3.8 g/L alum used in coagulation. The amount of sludge produced was found to be higher with EC as compared to coagulation which could be due to the fact that the electrochemical method was performed for a longer duration than conventional coagulation. For minimal sludge generation, EC reaction time should be ∼30 min. Further studies with EC process on costing and sludge generation will help to advance the technology for wastewater treatment.
Treatment of sugar beet extraction juice stillage by natural coagulants extracted from common bean
Prodanović Jelena M.; Šćiban Marina B.; Antov Mirjana G.; Kukić Dragana V.; Vasić Vesna M.
2015-01-01
Distillery wastewaters have a great pollution potential, and pollution caused by them is one of the most critical environmental issues. This study is concerned with the coagulation efficiency of a new, environmental friendly, natural coagulant extracted from common bean seeds in the primary treatment of distillery wastewater in the bioethanol production from sugar beet juice. Active coagulation components were extracted from ground seeds of common bean with...
Effect of Centrifuge Temperature on Routine Coagulation Tests.
Yazar, Hayrullah; Özdemir, Fatma; Köse, Elif
2018-01-01
This study investigated the effects of cooled and standard centrifuges on the results of coagulation tests to examine the effects of centrifugation temperature. Equal-volume blood samples from each patient were collected at the same time intervals and subjected to standard (25°C) and cooled centrifugation (2-4°C). Subsequently, the prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (aPTT), fibrinogen, and D-dimer values were determined in runs with the same lot numbers in the same coagulation device using the Dia-PT R (PT and INR), Dia-PTT-liquid (aPTT), Dia-FIB (fibrinogen), and Dia-D-dimer kits, respectively. The study enrolled 771 participants. The PT was significantly (p centrifuges were as follows: PT 10.30 versus 10.50 s; PT (INR) 1.04 versus 1.09 s; APTT 28.90 versus 29.40 s; fibrinogen 321.5 versus 322.1 mg/dL; and D-dimer 179.5 versus 168.7 µg FEU/mL. There were significant differences (p centrifuges. Centrifuge temperature can have a significant effect on the results of coagulation tests. However, broad and specific disease-based studies are needed. © 2018 S. Karger AG, Basel.
Numerical Simulation of the Coagulation Dynamics of Blood
Directory of Open Access Journals (Sweden)
T. Bodnár
2008-01-01
Full Text Available The process of platelet activation and blood coagulation is quite complex and not yet completely understood. Recently, a phenomenological meaningful model of blood coagulation and clot formation in flowing blood that extends existing models to integrate biochemical, physiological and rheological factors, has been developed. The aim of this paper is to present results from a computational study of a simplified version of this coupled fluid-biochemistry model. A generalized Newtonian model with shear-thinning viscosity has been adopted to describe the flow of blood. To simulate the biochemical changes and transport of various enzymes, proteins and platelets involved in the coagulation process, a set of coupled advection–diffusion–reaction equations is used. Three-dimensional numerical simulations are carried out for the whole model in a straight vessel with circular cross-section, using a finite volume semi-discretization in space, on structured grids, and a multistage scheme for time integration. Clot formation and growth are investigated in the vicinity of an injured region of the vessel wall. These are preliminary results aimed at showing the validation of the model and of the numerical code.
Coagulation competence and fluid recruitment after moderate blood loss in young men
DEFF Research Database (Denmark)
Zaar, Morten; Mørkeberg, Jakob; Pott, Frank C
2014-01-01
The coagulation system is activated by a reduction of the central blood volume during orthostatic stress and lower body negative pressure suggesting that also a blood loss enhances coagulation. During bleeding, however, the central blood volume is supported by fluid recruitment to the circulation...
Brownian coagulation at high particle concentrations
Trzeciak, T.M.
2012-01-01
The process of Brownian coagulation, whereby particles are brought together by thermal motion and grow by collisions, is one of the most fundamental processes influencing the final properties of particulate matter in a variety of technically important systems. It is of importance in colloids,
Quantifying interspecific coagulation efficiency of phytoplankton
DEFF Research Database (Denmark)
Hansen, J.L.S.; Kiørboe, Thomas
1997-01-01
. nordenskjoeldii. Mutual coagulation between Skeletonema costatum and the non-sticky cel:ls of Ditylum brightwellii also proceeded with hall the efficiency of S. costatum alone. The latex beads were suitable to be used as 'standard particles' to quantify the ability of phytoplankton to prime aggregation...
Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.
Chen, Liming; Chen, Yu
2015-01-01
Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.
The Inflammatory Actions of Coagulant and Fibrinolytic Proteases in Disease
Directory of Open Access Journals (Sweden)
Michael Schuliga
2015-01-01
Full Text Available Aside from their role in hemostasis, coagulant and fibrinolytic proteases are important mediators of inflammation in diseases such as asthma, atherosclerosis, rheumatoid arthritis, and cancer. The blood circulating zymogens of these proteases enter damaged tissue as a consequence of vascular leak or rupture to become activated and contribute to extravascular coagulation or fibrinolysis. The coagulants, factor Xa (FXa, factor VIIa (FVIIa, tissue factor, and thrombin, also evoke cell-mediated actions on structural cells (e.g., fibroblasts and smooth muscle cells or inflammatory cells (e.g., macrophages via the proteolytic activation of protease-activated receptors (PARs. Plasmin, the principle enzymatic mediator of fibrinolysis, also forms toll-like receptor-4 (TLR-4 activating fibrin degradation products (FDPs and can release latent-matrix bound growth factors such as transforming growth factor-β (TGF-β. Furthermore, the proteases that convert plasminogen into plasmin (e.g., urokinase plasminogen activator evoke plasmin-independent proinflammatory actions involving coreceptor activation. Selectively targeting the receptor-mediated actions of hemostatic proteases is a strategy that may be used to treat inflammatory disease without the bleeding complications of conventional anticoagulant therapies. The mechanisms by which proteases of the coagulant and fibrinolytic systems contribute to extravascular inflammation in disease will be considered in this review.
Kiliç, Mehtap Gülsün; Hoşten, Cetin; Demirci, Sahinde
2009-11-15
This paper attempts to compare electrocoagulation using aluminum anodes and stainless steel cathodes with conventional coagulation by aluminum sulfate dosing on aqueous suspensions of ultrafine quartz. Several key parameters affecting the efficiency of electrocoagulation and coagulation were investigated with laboratory scale experiments in search of optimal parameter values. Optimal values of the parameters were determined on the basis of the efficiency of turbidity removal from ultrafine quartz suspensions. The parameters investigated in the study were suspension pH, electrical potential, current density, electrocoagulation time, and aluminum dosage. A comparison between electrocoagulation and coagulation was made on the basis of total dissolved aluminum, revealing that electrocoagulation and coagulation were equally effective at the same aluminum dosage for the removal of quartz particles from suspensions. Coagulation, however, was more effective in a wider pH range (pH 6-9) than electrocoagulation which yielded optimum effectiveness in a relatively narrower pH range around 9, where, in both methods, these pH values corresponded to near-zero zeta potentials of quartz particles. Furthermore, experimental results confirmed that electrocoagulation could display some pH buffering capacity. The kinetics of electrocoagulation was very fast (<10 min) in approaching a residual turbidity, which could be modeled with a second-order rate equation.
Improvement of NOM Removal from Water Resources by Modifying the Coagulation Process
Directory of Open Access Journals (Sweden)
F Vaezi, A Mohagheghian, J Nouri, MR Eshraghian, A Ghasri
2005-01-01
Full Text Available As a result of the regulations on DBPs, interest in NOM removal is increasing and many water treatment plants in developed countries have started to measure the concentration of TOC in their finished waters. Promulgation of the rules will substantially increase these efforts in other countries too. Since the cost of TOC (and DBPs determination was high, it was decided to study the traditional analysis of COD as a surrogate measure to detect the organic constituents in raw water and the extent to which optimized coagulation with ferric chloride can increase COD removal. The two water samples studied belonged to Karaj and Jajrood Rivers. For both samples the observed values of COD removal by coagulation at lower pH (about 1-1.5 pH values less than the regular pH were about 85-95 percent without making water turbidity unacceptable. In order to determine the effects of organic content on coagulation, synthetic samples were also prepared with much higher COD values. Again, considerable increases in COD removal have been observed for most of these samples only by decreasing 0.5-2 pH value. The results indicated that a modified coagulation process without need to much increasing the amount of coagulant can be developed for these water samples.
Comparison of electrocoagulation and chemical coagulation for heavy metal removal
Energy Technology Data Exchange (ETDEWEB)
Akbal, F.; Camci, S. [Ondokuz Mayis University, Engineering Faculty, Environmental Engineering Department, Kurupelit, Samsun (Turkey)
2010-10-15
Copper (Cu), chromium (Cr), and nickel (Ni) removal from metal plating wastewater by electrocoagulation and chemical coagulation was investigated. Chemical coagulation was performed using either aluminum sulfate or ferric chloride, whereas electrocoagulation was done in an electrolytic cell using aluminum or iron electrodes. By chemical coagulation, Cu-, Cr-, and Ni-removal of 99.9 % was achieved with aluminum sulfate and ferric chloride dosages of 500, 1000, and 2000 mg L{sup -1}, respectively. Removal of metals by electrocoagulation was affected by the electrode material, wastewater pH, current density, number of electrodes, and electrocoagulation time. Electrocoagulation with iron electrodes at a current density of 10 mA cm{sup -2}, electrocoagulation time of 20 min, and pH 3.0 resulted in 99.9 % Cu-, 99.9 % Cr-, and 98 % Ni-removal. (Abstract Copyright [2010], Wiley Periodicals, Inc.)
Lumped model for rotational modes in phononic crystals
Peng, Pai
2012-10-16
We present a lumped model for the rotational modes induced by the rotational motion of individual scatterers in two-dimensional phononic crystals comprised of square arrays of solid cylindrical scatterers in solid hosts. The model provides a physical interpretation of the origin of the rotational modes, reveals the important role played by the rotational motion in determining the band structure, and reproduces the dispersion relations in a certain range. The model increases the possibilities of manipulating wave propagation in phononic crystals. In particular, expressions derived from the model for eigenfrequencies at high symmetry points unambiguously predict the presence of a new type of Dirac-like cone at the Brillouin center, which is found to be the result of accidental degeneracy of the rotational and dipolar modes.
Lumped model for rotational modes in phononic crystals
Peng, Pai; Mei, Jun; Wu, Ying
2012-01-01
We present a lumped model for the rotational modes induced by the rotational motion of individual scatterers in two-dimensional phononic crystals comprised of square arrays of solid cylindrical scatterers in solid hosts. The model provides a physical interpretation of the origin of the rotational modes, reveals the important role played by the rotational motion in determining the band structure, and reproduces the dispersion relations in a certain range. The model increases the possibilities of manipulating wave propagation in phononic crystals. In particular, expressions derived from the model for eigenfrequencies at high symmetry points unambiguously predict the presence of a new type of Dirac-like cone at the Brillouin center, which is found to be the result of accidental degeneracy of the rotational and dipolar modes.
20 CFR 222.31 - Relationship as child for annuity and lump-sum payment purposes.
2010-04-01
... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false Relationship as child for annuity and lump... UNDER THE RAILROAD RETIREMENT ACT FAMILY RELATIONSHIPS Relationship as Child § 222.31 Relationship as... the employee. For procedures on how a determination of the person's relationship to the employee is...
Torres, Luis G; Belloc, Claudia; Vaca, Mabel; Iturbe, Rosario; Bandala, Erick R
2009-11-01
Wastewater produced in the contaminated soil washing was treated by means of coagulation-flocculation (CF) process. The wastewater contained petroleum hydrocarbons, a surfactant, i.e., sodium dodecyl sulfate (SDS) as well as salts, brownish organic matter and other constituents that were lixiviated from the soil during the washing process. The main goal of this work was to develop a process for treating the wastewaters generated when washing hydrocarbon-contaminated soils in such a way that it could be recycled to the washing process, and also be disposed at the end of the process properly. A second objective was to study the relationship among the coagulant and flocculant doses and the pH at which the CF process is developed, for systems where methylene blue active substances (MBAS) as well as oil and greases were present. The results for the selection of the right coagulant and flocculant type and dose, the optimum pH value for the CF process and the interactions among the three parameters are detailed along this work. The best coagulant and flocculant were FeCl(3) and Tecnifloc 998 at doses of 4,000 and 1 mg/L, correspondingly at pH of 5. These conditions gave color, turbidity, chemical oxygen demand (COD) and conductivity removals of 99.8, 99.6, 97.1 and 35%, respectively. It was concluded that it is feasible to treat the wastewaters generated in the contaminated soil washing process through CF process, and therefore, wastewaters could be recycled to the washing process or disposed to drainage.
REMOVAL OF PHENOL AND SURFACTANT FROM LANDFILL LEACHATE BY COAGULATION-FLOCCULATION PROCESS
Directory of Open Access Journals (Sweden)
H. BAKRAOUY
2016-02-01
Full Text Available Following the action of rainfall and natural fermentation, the stored waste produces a liquid fraction called leachate. This leachate is rich in organic matter (biodegradable but also refractory and trace elements. There are many techniques of treating the leachate, in particular, biological, physicochemical, membrane processes. The choice of a technique instead of another depends on several parameters including: the age of the leachate, composition... In this work we applied a coagulation-flocculation process to treat intermediate landfill leachate of Rabat city with a combined ferric chloride coagulant and a polymer flocculant. We were inspired by full factorial design, including twenty five experiments, to determine optimal dosages of coagulant and flocculant. We operate at pH 8.4, the best removal efficiencies obtained were 88 % for Turbidity, 98 % for Phenol and 82 % for surfactant. The optimum dosages values determined by this study were 13.2 g∙L-1 of coagulant, 62 mL∙L-1 of flocculant.
Isokawa, Naho; Fueda, Kazuki; Miyagawa, Korin; Kanno, Kenichi
2015-01-01
Poly(vinyl alcohol) (PVA) precipitates in many kinds of aqueous salt solutions. While sodium sulfate, a coagulant for PVA fiber, precipitates PVA to yield a white rigid gel, coagulation of PVA with aluminum sulfate, a coagulant for water treatment, yields a slime-like viscoelastic fluid. One type of homemade slime is prepared under basic…
Removal of congo red and methylene blue from waste water using coagulation
International Nuclear Information System (INIS)
Ghaffar, S.; Nosheen, S.; Ahmad, N.
2011-01-01
The textile industry has been condemned as being one of the world's worst offenders in terms of pollution Because of increasing population and industrial developments, a huge amount of wastewater is discharged to the environment above the level that the nature can eliminate. Many techniques like oxidation, reduction, physical treatment and biological method are available for removal of colored dyes from wastewater. The work presented here involved the decolorisation of wastewater containing congo red and methylene blue using various coagulants such as alum, bentonite and lime. The effect of various experimental factors such as dosage of coagulants, contact time between coagulant and dye and concentration of dyes and working environment like shaking and static was studied. Under static condition alum give almost 43% removal of congo red while with 10 minutes shaking 74 % removal of 80 dye was achieved with same coagulant. The highest removal of congo red was found to be 99.5 % by using alum after 30 minutes of shaking but in case of methylene blue it intensified the color and gave negative results. Lime gave only 33 % color removal of congo red under static conditions while 57% color was removed under shaking conditions. Maximum color removal achieved by lime was 89% at 40 minutes with shaking condition. Lime gave 60% removal of methylene blue in static condition and 90% removal in shaking condition and maximum absorbance at 80 ppm was 90%. Bentonite also used for the removal of methylene blue and gave 89% removal in shaking condition. By increasing shaking time %age removal increased to 100% at 40 min. And amount of coagulant increased the removal efficiency it attained 100% in both lime and bentonite coagulant for methylene blue Overall alum was found to be better coagulant for the removal of congo red from its aqueous solution. Lime and bentonite both proved better and economical for removal of methylene blue from aqueous solution at lab scale. (author)
Comprehensive reuse of drinking water treatment residuals in coagulation and adsorption processes.
Jung, Kyung-Won; Hwang, Min-Jin; Park, Dae-Seon; Ahn, Kyu-Hong
2016-10-01
While drinking water treatment residuals (DWTRs) inevitably lead to serious problems due to their huge amount of generation and limitation of landfill sites, their unique properties of containing Al or Fe contents make it possible to reuse them as a beneficial material for coagulant recovery and adsorbent. Hence, in the present study, to comprehensively handle and recycle DWTRs, coagulant recovery from DWTRs and reuse of coagulant recovered residuals (CRs) were investigated. In the first step, coagulant recovery from DWTRs was conducted using response surface methodology (RSM) for statistical optimization of independent variables (pH, solid content, and reaction time) on response variable (Al recovery). As a result, a highly acceptable Al recovery of 97.5 ± 0.4% was recorded, which corresponds to 99.5% of the predicted Al recovery. Comparison study of recovered and commercial coagulant from textile wastewater treatment indicated that recovered coagulant has reasonable potential for use in wastewater treatment, in which the performance efficiencies were 68.5 ± 2.1% COD, 97.2 ± 1.9% turbidity, and 64.3 ± 1.0% color removals at 50 mg Al/L. Subsequently, in a similar manner, RSM was also applied to optimize coagulation conditions (Al dosage, initial pH, and reaction time) for the maximization of real cotton textile wastewater treatment in terms of COD, turbidity, and color removal. Overall performance revealed that the initial pH had a remarkable effect on the removal performance compared to the effects of other independent variables. This is mainly due to the transformation of metal species form with increasing or decreasing pH conditions. Finally, a feasibility test of CRs as adsorbent for phosphate adsorption from aqueous solution was conducted. Adsorption equilibrium of phosphate at different temperatures (10-30 °C) and initial levels of pH (3-11) indicated that the main mechanisms of phosphate adsorption onto CRs are endothermic and chemical
21 CFR 864.5400 - Coagulation instrument.
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Coagulation instrument. 864.5400 Section 864.5400 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES HEMATOLOGY AND PATHOLOGY DEVICES Automated and Semi-Automated Hematology Devices § 864...
Directory of Open Access Journals (Sweden)
Maowei He
2014-01-01
Full Text Available The major challenge in printable electronics fabrication is the print resolution and accuracy. In this paper, the dynamic lumped element model (DLEM is proposed to directly simulate an inkjet-printed nanosilver droplet formation process and used for predictively controlling jetting characteristics. The static lumped element model (LEM previously developed by the authors is extended to dynamic model with time-varying equivalent circuits to characterize nonlinear behaviors of piezoelectric printhead. The model is then used to investigate how performance of the piezoelectric ceramic actuator influences jetting characteristics of nanosilver ink. Finally, the proposed DLEM is applied to predict the printing quality using nanosilver ink. Experimental results show that, compared to other analytic models, the proposed DLEM has a simpler structure with the sufficient simulation and prediction accuracy.
International Nuclear Information System (INIS)
Kikuchi, Yoshinori; Domon, Kaoru; Otsuka, Takafumi
2011-01-01
Salvage therapy for residual or relapsed esophageal cancer after chemoradiotherapy (CRT) has not yet been established. We retrospectively evaluated relapse-free survival (RFS) after local recurrence following CRT and local control rate in patients who underwent argon plasma coagulation (APC). We reviewed the records of 14 patients who underwent APC after CRT for esophageal cancer at our department between 2001 and 2010 and analyzed overall survival (OS), 5-year survival rate, local control rate after APC and RFS-defined as the period between the end of CRT and the time when an iodine-negative area was found. Median OS and median RFS (mRFS) were 33 months and 6 months, respectively. The 5-year survival rate was 16.2%, and the local control rate after APC was 71.4% (10/14). RFS was significantly longer in the T1 group than in the T2/T3 group (p=0.03); the local control rate after APC did not significantly differ between groups. The high-dose (HD) radiation group had a significantly longer RFS and a tendency toward a higher local control rate after APC than did the standard-dose (SD) radiation group. APC was safe and resulted in a high rate of local control, regardless of T factor. HD radiation was associated with longer RFS and greater efficacy of APC treatment for local recurrence. (author)
Chang, Feng-Yu; Tsai, Meng-Tsan; Wang, Zu-Yi; Chi, Chun-Kai; Lee, Cheng-Kuang; Yang, Chih-Hsun; Chan, Ming-Che; Lee, Ya-Ju
2015-11-16
Blood coagulation is the clotting and subsequent dissolution of the clot following repair to the damaged tissue. However, inducing blood coagulation is difficult for some patients with homeostasis dysfunction or during surgery. In this study, we proposed a method to develop an integrated system that combines optical coherence tomography (OCT) and laser microsurgery for blood coagulation. Also, an algorithm for positioning of the treatment location from OCT images was developed. With OCT scanning, 2D/3D OCT images and angiography of tissue can be obtained simultaneously, enabling to noninvasively reconstruct the morphological and microvascular structures for real-time monitoring of changes in biological tissues during laser microsurgery. Instead of high-cost pulsed lasers, continuous-wave laser diodes (CW-LDs) with the central wavelengths of 450 nm and 532 nm are used for blood coagulation, corresponding to higher absorption coefficients of oxyhemoglobin and deoxyhemoglobin. Experimental results showed that the location of laser exposure can be accurately controlled with the proposed approach of imaging-based feedback positioning. Moreover, blood coagulation can be efficiently induced by CW-LDs and the coagulation process can be monitored in real-time with OCT. This technology enables to potentially provide accurate positioning for laser microsurgery and control the laser exposure to avoid extra damage by real-time OCT imaging.
Directory of Open Access Journals (Sweden)
Thomas Decker Christensen
Full Text Available Knowledge about the impact of Low-Molecular-Weight Heparin (LMWH on the coagulation system in patients undergoing minimal invasive lung cancer surgery is sparse. The aim of this study was to assess the effect of LMWH on the coagulation system in patients undergoing Video-Assisted Thoracoscopic Surgery (VATS lobectomy for primary lung cancer.Sixty-three patients diagnosed with primary lung cancer undergoing VATS lobectomy were randomized to either subcutaneous injection with dalteparin (Fragmin® 5000 IE once daily or no intervention. Coagulation was assessed pre-, peri-, and the first two days postoperatively by standard coagulation blood test, thromboelastometry (ROTEM® and thrombin generation.Patients undergoing potential curative surgery for lung cancer were not hypercoagulable preoperatively. There was no statistically significant difference in the majority of the assessed coagulation parameters after LMWH, except that the no intervention group had a higher peak thrombin and a shorter INTEM clotting time on the first postoperative day and a lower fibrinogen level on the second postoperative day. A lower level of fibrin d-dimer in the LMWH group was found on the 1. and 2.postoperative day, although not statistical significant. No differences were found between the two groups in the amount of bleeding or number of thromboembolic events.Use of LMWH administered once daily as thromboprophylaxis did not alter the coagulation profile per se. As the present study primarily evaluated biochemical endpoints, further studies using clinical endpoints are needed in regards of an optimized thromboprophylaxis approach.
Influence of micellar calcium and phosphorus on rennet coagulation properties of cows milk.
Malacarne, Massimo; Franceschi, Piero; Formaggioni, Paolo; Sandri, Sandro; Mariani, Primo; Summer, Andrea
2014-05-01
The main requirement for milk processed in most cheese typologies is its rennet coagulation ability. Despite the increasing number of studies, the causes for abnormal coagulation of milk are not fully understood. The aim of this study was to ascertain relationships between milk characteristics and its rennet coagulation ability, focusing on the influence of calcium (Ca) and phosphorus (P). Ca and P are essential constituents of the micelles. Micellar P can be present as part of colloidal calcium phosphate (inorganic-P) or covalently bound to caseins as phosphate groups (casein-P). Eighty one herd milk samples (SCCproperties. Optimal milk was characterised by the highest contents of major constituents, protein fractions and minerals, lowest content of chloride and highest values of titratable acidity. Non-coagulating milk was characterised by the highest values of pH and the lowest of titratable acidity. At micellar level, Optimal milk showed the highest values of colloidal Ca, casein-P and colloidal Mg (g/100 g casein), while Non-coagulating milk showed the lowest values. Interestingly, there was no statistical difference regarding the content of colloidal inorganic-P (g/100 g casein) between Optimal and Non-coagulating milks. Overall, high mineralisation of the micelle (expressed as g inorganic-P/100 g casein) positively affect its rennetability. However, excessive mineralisation could lead to a reduction of the phosphate groups (g casein-P/100 g casein) available for curd formation.
International Nuclear Information System (INIS)
Caldarelli, Marco M.; Dias, Oscar J.C.; Emparan, Roberto; Klemm, Dietmar
2009-01-01
The old suggestive observation that black holes often resemble lumps of fluid has recently been taken beyond the level of an analogy to a precise duality. We investigate aspects of this duality, and in particular clarify the relation between area minimization of the fluid vs. area maximization of the black hole horizon, and the connection between surface tension and curvature of the fluid, and surface gravity of the black hole. We also argue that the Rayleigh-Plateau instability in a fluid tube is the holographic dual of the Gregory-Laflamme instability of a black string. Associated with this fluid instability there is a rich variety of phases of fluid solutions that we study in detail, including in particular the effects of rotation. We compare them against the known results for asymptotically flat black holes finding remarkable agreement. Furthermore, we use our fluid results to discuss the unknown features of the gravitational system. Finally, we make some observations that suggest that asymptotically flat black holes may admit a fluid description in the limit of large number of dimensions.
Coagulation profiles of healthy Andalusian donkeys are different than those of healthy horses.
Mendoza, F J; Perez-Ecija, R A; Monreal, L; Estepa, J C
2011-01-01
Coagulation disorders are frequently diagnosed, especially in hospitalized equidae, and result in increased morbidity and mortality. However, hemostatic reference intervals have not been established for donkeys yet. To determine whether the most common coagulation parameters used in equine practice are different between healthy donkeys and horses. Thirty-eight healthy donkeys and 29 healthy horses. Blood samples were collected to assess both coagulation and fibrinolytic systems by determination of platelet count, fibrinogen concentration, clotting times (prothrombin time [PT] and activated partial thromboplastin time [aPTT]), fibrin degradation products (FDP) and D-Dimer concentrations. PT and aPTT in donkeys were significantly (P donkeys than in horses. The coagulation parameters most commonly determined in equine practice are different in donkeys compared with horses. Thus, the use of normal reference ranges reported previously for healthy horses in donkeys might lead to a misdiagnosis of coagulopathy in healthy donkeys, and unnecessary treatments in sick donkeys. This is the first report of normal coagulation profile results in donkeys, and further studies are warranted to elucidate the physiological mechanisms of the differences observed between donkeys and horses. Copyright © 2011 by the American College of Veterinary Internal Medicine.
Energy Technology Data Exchange (ETDEWEB)
Tormoen, Garth W.; Cianchetti, Flor A. [Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR (United States); Bock, Paul E. [Department of Pathology, Microbiology and Immunology, Vanderbilt University School of Medicine, Nashville, TN (United States); McCarty, Owen J. T., E-mail: tormoeng@ohsu.edu [Department of Biomedical Engineering, Oregon Health and Science University, Portland, OR (United States); Department of Cell and Developmental Biology, Oregon Health and Science University, Portland, OR (United States); Division of Hematology and Medical Oncology, Department of Medicine, Oregon Health and Science University, Portland, OR (United States)
2012-09-06
Metastatic cancer is associated with a hypercoagulable state, and pathological venous thromboembolic disease is a significant source of morbidity and the second leading cause of death in patients with cancer. Here we aimed to develop a novel labeling strategy to detect and quantify procoagulant circulating tumor cells (CTCs) from patients with metastatic cancer. We hypothesize that the enumeration of procoagulant CTCs may be prognostic for the development of venous thrombosis in patients with cancer. Our approach is based on the observation that cancer cells are capable of initiating and facilitating cell-mediated coagulation in vitro, whereby activated coagulation factor complexes assemble upon cancer cell membrane surfaces. Binding of fluorescently labeled, active site-inhibited coagulation factors VIIa, Xa, and IIa to the metastatic breast cancer cell line, MDA-MB-231, non-metastatic colorectal cell line, SW480, or metastatic colorectal cell line, SW620, was characterized in a purified system, in anticoagulated blood and plasma, and in plasma under conditions of coagulation. We conclude that a CTC labeling strategy that utilizes coagulation factor-based fluorescent probes may provide a functional assessment of the procoagulant potential of CTCs, and that this strategy is amenable to current CTC detection platforms.
Isolation and characterization of coagulant extracted from Moringa oleifera seed by salt solution.
Okuda, T; Baes, A U; Nishijima, W; Okada, M
2001-02-01
It is known that M. oleifera contains a natural coagulant in the seeds. In our previous research, the method using salt water to extract the active coagulation component from M. oleifera seeds was developed and compared with the conventional method using water. In this research, the active coagulation component was purified from a NaCl solution crude extract of Moringa oleifera seeds. The active component was isolated and purified from the crude extract through a sequence of steps that included salting-out by dialysis, removal of lipids and carbohydrates by homogenization with acetone, and anion exchange. Specific coagulation activity of the active material increased up to 34 times more than the crude extract after the ion exchange. The active component was not the same as that of water extract. The molecular weight was about 3000 Da. The Lowry method and the phenol-sulfuric acid method indicated that the active component was neither protein nor polysaccharide. The optimum pH of the purified active component for coagulation of turbidity was pH 8 and above. Different from the conventional water extracts, the active component can be used for waters with low turbidity without increase in the dissolved organic carbon concentration.
Lumped-parameter modeling of PWR downcomer and pressurizer for LOCA conditions
International Nuclear Information System (INIS)
Rohatgi, U.S.; Saha, P.; Dubow, A.A.
1978-01-01
Two lumped-parameter models, one for a PWR downcomer and the other for a pressurizer, are presented. The models are based on the transient, nonhomogeneous, drift-flux description of two-phase flow, and are suitable for simulating a hypothetical LOCA condition. Effects of thermal nonequilibrium are incorporated in the downcomer model, whereas the pressurizer model can track the interfaces among various flow regimes. Semiimplicit numerical schemes are used for solution. Encouraging results have been obtained for both the models. (author)
Directory of Open Access Journals (Sweden)
Kin Fong Lei
Full Text Available Blood coagulation is an extremely complicated and dynamic physiological process. Monitoring of blood coagulation is essential to predict the risk of hemorrhage and thrombosis during cardiac surgical procedures. In this study, a high throughput microfluidic chip has been developed for the investigation of the blood coagulation process under temperature and hematocrit variations. Electrical impedance of the whole blood was continuously recorded by on-chip electrodes in contact with the blood sample during coagulation. Analysis of the impedance change of the blood was conducted to investigate the characteristics of blood coagulation process and the starting time of blood coagulation was defined. The study of blood coagulation time under temperature and hematocrit variations was shown a good agreement with results in the previous clinical reports. The electrical impedance measurement for the definition of blood coagulation process provides a fast and easy measurement technique. The microfluidic chip was shown to be a sensitive and promising device for monitoring blood coagulation process even in a variety of conditions. It is found valuable for the development of point-of-care coagulation testing devices that utilizes whole blood sample in microliter quantity.
Tsang, V C; Wyatt, C R; Damian, R T
1979-06-01
The functional capabilities of a thermometric clot-timer have been demonstrated in a comparative study of human and mouse plasma coagulation. The influence of some variables on coagulation times of mouse and human plasmas were examined in activated partial thromboplastin time, one-stage prothrombin time, and Russell's viper venom time assays. Mouse plasma coagulation times were generally shorter and more reproducible than those of human plasma. Optimal assay conditions are also described.
Comparison of electrocoagulation and chemical coagulation ...
African Journals Online (AJOL)
In this work, electrocoagulation and chemical coagulation were applied to the exit effluent of a textile factory located at Douala (Cameroon).The investigations were focused on the operational (pH, conductivity) and pollution parameters (COD, total phosphorus, turbidity). The electrolytic treatment was carried out with 0.4 A ...
Enhancement of sedimentation and coagulation with static magnetic field
Zieliński, Marcin; Dębowski, Marcin; Hajduk, Anna; Rusanowska, Paulina
2017-11-01
The static magnetic field can be an alternative method for wastewater treatment. It has been proved that this physical factor, accelerates the biochemical processes, catalyzes advanced oxidation, intensifies anaerobic and aerobic processes or reduces swelling of activated sludge. There are also reports proving the positive impact of the static magnetic field on the coagulation and sedimentation, as well as the conditioning and dewatering of sludge. In order to be applied in larger scale the published results should be verified and confirmed. In the studies, the enhancement of sedimentation by the static magnetic field was observed. The best sedimentation was noted in the experiment, where magnetizers were placed on activated sludge bioreactor and secondary settling tank. No effect of the static magnetic field on coagulation with the utilization of PIX 113 was observed. However, the static magnetic field enhanced coagulation with the utilization of PAX-XL9. The results suggest that increased sedimentation of colloids and activated sludge, can in practice mean a reduction in the size of the necessary equipment for sedimentation with an unchanged efficiency of the process.
Kumar, Abhijeet; Nidheesh, P V; Suresh Kumar, M
2018-08-01
Treatment of composite wastewater generating from the industrial estates is a great challenge. The present study examines the applicability of aerated electrocoagulation and modified peroxi-coagulation processes for removing color and COD from composite wastewater. Iron plates were used as anodes and cathodes in both electrochemical processes and experiments were carried out in a working volume of 2 L. Aeration enhanced the efficiency of electrocoagulation process significantly. More than 50% of COD and 60% of color were removed after 1 h of electrocoagulation process operated at pH 3 and applied voltage of 1 V. Efficiency of the modified peroxi-coagulation process was significantly higher than that of aerated electrocoagulation. COD and color removal efficiencies of the modified peroxi-coagulation process were found as 77.7% and 97%, respectively after 1 h of electrolysis operated at 1 V, solution pH 3 and 50 mM hydrogen peroxide addition. This improved efficiency of modified peroxi-coagulation compared to aerated electrocoagulation is mainly due to the attack of in-situ generated hydroxyl radicals. Copyright © 2018 Elsevier Ltd. All rights reserved.
Monte Carlo simulation of aggregate morphology for simultaneous coagulation and sintering
International Nuclear Information System (INIS)
Schmid, Hans-Joachim; Tejwani, Saurabh; Artelt, Christian; Peukert, Wolfgang
2004-01-01
A model for simulation of the three-dimensional morphology of nano-structured aggregates formed by concurrent coagulation and sintering is presented. Diffusion controlled cluster-cluster aggregation is assumed to be the prevailing coagulation mechanism which is implemented using a Monte-Carlo algorithm. Sintering is modeled as a successive overlapping of spherical primary particles, which are allowed to grow as to preserve overall mass. Simulations are characterized by individual ratios τ of characteristic collision to fusion time. A number of resulting aggregate-structures is displayed and reveals structure formation by coagulation and sintering for different values of τ. These aggregates are described qualitatively and quantitatively by their mass fractal dimension D f and radius of gyration. The fractal dimension increases from 1.86 for pure aggregation to ∼ 2.75 for equal characteristic time scales. As sintering turns out to be more and more relevant, increasingly compact aggregates start to form and the radius of gyration decreases significantly. The simulation results clearly reveal a strong dependence of the fractal dimension on the kinetics of the concurrent coagulation and sintering processes. Considering appropriate values of D f in aerosol process simulations may therefore be important in many cases
Sartim, Marco A; Cezarette, Gabriel N; Jacob-Ferreira, Anna L; Frantz, Fabiani G; Faccioli, Lucia H; Sampaio, Suely V
2017-10-01
Snake venom toxins that activate coagulation factors are key players in the process of venom-induced coagulopathy, and account for severe clinical manifestations. The present study applies a variety of biochemical, hematological, and histopathological approaches to broadly investigate the intravascular and systemic effects of moojenactivase (MooA), the first described PIIId subclass metalloprotease isolated from Bothrops sp. venom that activates coagulation factors. MooA induced consumption coagulopathy with high toxic potency, characterized by prolongation of prothrombin and activated partial thromboplastin time, consumption of fibrinogen and the plasma coagulation factors X and II, and thrombocytopenia. MooA promoted leukocytosis and expression of the proinflammatory cytokines interleukin-6 and tumor necrosis factor-α, accompanied by tissue factor-dependent procoagulant activity in peripheral blood mononuclear cells. This metalloprotease also caused intravascular hemolysis, elevated plasma levels of creatine kinase-MB, aspartate transaminase, and urea/creatinine, and induced morphopathological alterations in erythrocytes, heart, kidney, and lungs associated with thrombosis and hemorrhage. Diagnosis of MooA-induced disseminated intravascular coagulation represents an important approach to better understand the pathophysiology of Bothrops envenomation and develop novel therapeutic strategies targeting hemostatic disturbances. Copyright © 2017. Published by Elsevier B.V.
Enhanced Coagulation Efficiency of Moringa Oleifera Seeds Through Selective Oil Extraction
Directory of Open Access Journals (Sweden)
Suleyman A. Muyibi
2012-10-01
Full Text Available In this laboratory based study, varying quantities of oil, corresponding to 20 % w/w, 25 % w/w and 30 % w/w kernel weight extracted from Moringa oleifera seeds ( S1, S2, S3 respectively were applied in the coagulation of model turbid water (kaolin suspension and turbid river water samples from River Batang Kali and River Selangor in Malaysia to determine the percentage oil removed which gave the best coagulation efficiency. For model turbid water (kaolin suspension coagulation of low turbidity of 35 NTU, medium turbidity of 100 NTU and high turbidity of 300 NTU, sample S2 gave the best turbidity removal corresponding to 91.7%, 95.5% and 99% respectively. Application of sample S2 to River Batang Kali with low initial turbidity of 32 NTU and high initial turbidity of 502 NTU gave a highest turbidity removal of 69% and 99% respectively. Application to River Selangor with medium initial turbidity- of 87 NTU and high initial turbidity of 466 NTU gave a highest residual turbidity' of 94% and 98.9%, respectively.Key words: Moringa oleifera seed, selective oil extraction, coagulation, model turbid water (kaolin suspension, river water, turbidity removal.
Marobhe, N J; Dalhammar, G; Gunaratna, K R
2007-06-01
The coagulating properties of aqueous crude extracts and purified proteins of Vigna unguiculata and Parkinsonia aculeata seeds, which are traditional water coagulants in rural areas of Tanzania, were studied. The coagulation activity assays were done using one millilitre (ml) of kaolin water samples. Coagulating proteins were purified in two-step ion exchange chromatography. The properties of coagulant protein were compared with Moringa oleifera. Coagulating components eluted by 0.6 M NaCl in both coagulants are cationic proteins that have the molecular mass of about 6 kDa, which is very similar to that of M. oleifera. The proteins of V. unguiculata and P. aculeata eluted by 0.3 M NaCl also harbour coagulation activity but proteins eluted with 0.6 M NaCl have higher activity. The dosage for coagulation using purified proteins of both coagulants is about 5 to 10 times lower than that of crude seed extracts. The optimum floc settling time of water treated by crude seed extracts and purified proteins ranged between two and two and half hours. Coagulating proteins of both coagulants eluted by 0.6 M NaCl are thermoresistant and retained coagulation activity of 87% to 92% after boiling for two hours at 80 degrees C and one hour at 95 degrees C. Thermotolerant proteins of V. unguiculata eluted by 0.6 M NaCl and P. aculeata have wider pH range of 5.5 to 8.5 for coagulation activity than those of M. oleifera proteins. The present investigation reveals the possibility of using purified natural coagulants for water treatment to produce safe drinking water.
Lumped Parameter Models of the Central Nervous System for VIIP Research
Vera, J.; Mulugeta, L.; Nelson, E. S.; Raykin, J.; Feola, A.; Gleason, R.; Samuels, B.; Myers, J. G.
2015-01-01
INTRODUCTION: Current long-duration missions to the International Space Station and future exploration-class missions beyond low-Earth orbit, such as to Mars and asteroids, expose astronauts to increased risk of Visual Impairment and Intracranial Pressure (VIIP) syndrome [1]. It has been hypothesized that the headward shift of cerebral spinal fluid (CSF) and blood in microgravity may cause significant elevation of intracranial pressure (ICP), which in turn induces VIIP syndrome through biomechanical pathways [1, 2]. However, there is insufficient evidence to confirm this hypothesis. In this light, we are developing lumped-parameter models of fluid transport in the central nervous system (CNS) as a means to simulate the influence of microgravity on ICP. The CNS models will also be used in concert with the lumped parameter and finite element models of the eye described in the realted IWS abstracts submitted by Nelson et al., Feola et al. and Ethier et al. METHODS: We have developed a nine compartment CNS model (Figure 1) capable of both time-dependent and steady state fluid transport simulations, based on the works of Stevens et al. [3]. The breakdown of compartments within the model includes: vascular (3), CSF (2), brain (1) and extracranial (3). The boundary pressure in the Central Arteries [A] node is prescribed using an oscillating pressure function PA(t) simulating the carotid pulsatile pressure wave as developed by Linninger et al. [4]. For each time step, pressures are integrated through time using an adaptive-timestep 4th and 5th order Runga-Kutta solver. Once pressures are found, constitutive equations are used to solve for flowrates (Q) between each compartment. In addition to fluid flow between the different compartments, compliance (C) interactions between neighboring compartments are represented. We are also developing a second CNS model based on the works of Linninger et al. [4] which takes a more granular approach to represent the interactions of the
Lumped-Element Dynamic Electro-Thermal model of a superconducting magnet
Ravaioli, E.; Auchmann, B.; Maciejewski, M.; ten Kate, H. H. J.; Verweij, A. P.
2016-12-01
Modeling accurately electro-thermal transients occurring in a superconducting magnet is challenging. The behavior of the magnet is the result of complex phenomena occurring in distinct physical domains (electrical, magnetic and thermal) at very different spatial and time scales. Combined multi-domain effects significantly affect the dynamic behavior of the system and are to be taken into account in a coherent and consistent model. A new methodology for developing a Lumped-Element Dynamic Electro-Thermal (LEDET) model of a superconducting magnet is presented. This model includes non-linear dynamic effects such as the dependence of the magnet's differential self-inductance on the presence of inter-filament and inter-strand coupling currents in the conductor. These effects are usually not taken into account because superconducting magnets are primarily operated in stationary conditions. However, they often have significant impact on magnet performance, particularly when the magnet is subject to high ramp rates. Following the LEDET method, the complex interdependence between the electro-magnetic and thermal domains can be modeled with three sub-networks of lumped-elements, reproducing the electrical transient in the main magnet circuit, the thermal transient in the coil cross-section, and the electro-magnetic transient of the inter-filament and inter-strand coupling currents in the superconductor. The same simulation environment can simultaneously model macroscopic electrical transients and phenomena at the level of superconducting strands. The model developed is a very useful tool for reproducing and predicting the performance of conventional quench protection systems based on energy extraction and quench heaters, and of the innovative CLIQ protection system as well.
Energy Technology Data Exchange (ETDEWEB)
Kohlberg, I.
1993-06-01
This study provides a mathematical determination of the spatial distribution of aerosols due to turbulent shear coagulation and turbulent inertial coagulation, as applied to the conditions of the Kuwaiti Oil Fires (KOF) of 1991. Using an approximation from a forest fire for the normalized size distribution of aerosols, the downstream particle concentration is found by the concurrent solution of the coagulations' kinetics combined with turbulent atmospheric diffusion. The result shows the explicit dependence of the concentration on the following principal parameters: turbulent energy dissipation rate, turbulent diffusion constant, average wind speed, mass ejection from a well, Kolmorogov time scale for turbulence, and Kolmorogov length scale for turbulence. For very large values of turbulent energy dissipation rate, turbulent inertial coagulation is more effective than turbulent shear coagulation in particle growth. The spatial dependence of concentration attributed to turbulent coagulation may vary considerably. Depending on the choice of parameters, the importance of turbulent coagulation in particle transport processes may extend from less than a kilometer to tens of kilometers. Kuwaiti Oil Fires (KOF), Particle transport, Turbulent inertial coagulation, Turbulent shear coagulation.
Contact activation of blood-plasma coagulation
Golas, Avantika
Surface engineering of biomaterials with improved hemocompatibility is an imperative, given the widespread global need for cardiovascular devices. Research summarized in this dissertation focuses on contact activation of FXII in buffer and blood plasma frequently referred to as autoactivation. The extant theory of contact activation imparts FXII autoactivation ability to negatively charged, hydrophilic surfaces. According to this theory, contact activation of plasma involves assembly of proteins comprising an "activation complex" on activating surfaces mediated by specific chemical interactions between complex proteins and the surface. This work has made key discoveries that significantly improve our core understanding of contact activation and unravel the existing paradigm of plasma coagulation. It is shown herein that contact activation of blood factor XII (FXII, Hageman factor) in neat-buffer solution exhibits a parabolic profile when scaled as a function of silanized-glass-particle activator surface energy (measured as advancing water adhesion tension t°a=g° Iv costheta in dyne/cm, where g°Iv is water interfacial tension in dyne/cm and theta is the advancing contact angle). Nearly equal activation is observed at the extremes of activator water-wetting properties --36 moderated by adsorption of plasma proteins unrelated to coagulation through an "adsorption-dilution" effect that blocks FXII contact with hydrophobic activator surfaces. The adsorption-dilution effect explains the apparent specificity for hydrophilic activators pursued by earlier investigators. Finally a comparison of FXII autoactivation in buffer, serum, protein cocktail, and plasma solutions is shown herein. Activation of blood plasma coagulation in vitro by contact with material surfaces is demonstrably dependent on plasma-volume-to-activator-surface-area ratio. However, activation of factor XII dissolved in buffer, protein cocktail, heat-denatured serum, and FXI deficient plasma does not
Sartim, Marco A; Costa, Tassia R; Laure, Helen J; Espíndola, Milena S; Frantz, Fabiani G; Sorgi, Carlos A; Cintra, Adélia C O; Arantes, Eliane C; Faccioli, Lucia H; Rosa, José C; Sampaio, Suely V
2016-05-01
Coagulopathies following snakebite are triggered by pro-coagulant venom toxins, in which metalloproteases play a major role in envenomation-induced coagulation disorders by acting on coagulation cascade, platelet function and fibrinolysis. Considering this relevance, here we describe the isolation and biochemical characterization of moojenactivase (MooA), a metalloprotease from Bothrops moojeni snake venom, and investigate its involvement in hemostasis in vitro. MooA is a glycoprotein of 85,746.22 Da, member of the PIIId group of snake venom metalloproteases, composed of three linked disulfide-bonded chains: an N-glycosylated heavy chain, and two light chains. The venom protease induced human plasma clotting in vitro by activating on both blood coagulation factors II (prothrombin) and X, which in turn generated α-thrombin and factor Xa, respectively. Additionally, MooA induced expression of tissue factor (TF) on the membrane surface of peripheral blood mononuclear cells (PBMC), which led these cells to adopt pro-coagulant characteristics. MooA was also shown to be involved with production of the inflammatory mediators TNF-α, IL-8 and MCP-1, suggesting an association between MooA pro-inflammatory stimulation of PBMC and TF up-regulation. We also observed aggregation of washed platelets when in presence of MooA; however, the protease had no effect on fibrinolysis. Our findings show that MooA is a novel hemostatically active metalloprotease, which may lead to the development of coagulopathies during B. moojeni envenomation. Moreover, the metalloprotease may contribute to the development of new diagnostic tools and pharmacological approaches applied to hemostatic disorders.
EFFECTS OF ORAL CONTRACEPTIVES ON COAGULATING FACTORS
Directory of Open Access Journals (Sweden)
H.R. Sadeghipour Roudsari.
1997-06-01
Full Text Available Thirty young, healthy, nonsmoking women (mean age approximately 28 years taking low-dose oral contraceptive pills were recruited for the study of the effects of these pills on coagulating factors. Twenty subjects were taking LD pill (Ethinyl estradiol 0.03 mg, levonorgestrel 0.15 mg and 10 others were taking Cilest (Ethinyl estradiol 0.035 mg, Norgestimate 0.25 mg for six months. The control subjects did not receive any oral contraceptives or other medications. Our results showed that:"n1. There is no significant difference between the effects of LD and Cilest (with a different progestin content on coagulating factors."n2. No significant changes were observed between both LD users and controls in PT, APTT, and fibrinogen levels."n3. No significant changes were observed between both Cilest users and controls in PT, APTT, and fibrinogen levels."n
A lumped model for rotational modes in periodic solid composites
Peng, Pai; Asiri, Sharefa M.; Zhang, Xiujuan; Li, Yan; Wu, Ying
2013-01-01
We present a lumped model to study the rotational modes in a type of two-dimensional periodic solid composites comprised of a square array of rubber-coated steel cylinders embedded in an epoxy matrix. The model captures the physical essence of rotational modes in such systems for various combinations of material parameters, and, therefore it is able to describe the transition behaviour when the system is gradually adjusted from an elastic metamaterial to an elastic phononic crystal. From the model, we can define a transition zone which separates the typical elastic metamaterials and the phononic crystals.
A lumped model for rotational modes in periodic solid composites
Peng, Pai
2013-10-01
We present a lumped model to study the rotational modes in a type of two-dimensional periodic solid composites comprised of a square array of rubber-coated steel cylinders embedded in an epoxy matrix. The model captures the physical essence of rotational modes in such systems for various combinations of material parameters, and, therefore it is able to describe the transition behaviour when the system is gradually adjusted from an elastic metamaterial to an elastic phononic crystal. From the model, we can define a transition zone which separates the typical elastic metamaterials and the phononic crystals.
DEFF Research Database (Denmark)
Bahman, Amir Sajjad; Ma, Ke; Blaabjerg, Frede
2018-01-01
Detailed thermal dynamics of high power IGBT modules are important information for the reliability analysis and thermal design of power electronic systems. However, the existing thermal models have their limits to correctly predict these complicated thermal behavior in the IGBTs: The typically used...... thermal model based on one-dimensional RC lumps have limits to provide temperature distributions inside the device, moreover some variable factors in the real-field applications like the cooling and heating conditions of the converter cannot be adapted. On the other hand, the more advanced three......-dimensional thermal models based on Finite Element Method (FEM) need massive computations, which make the long-term thermal dynamics difficult to calculate. In this paper, a new lumped three-dimensional thermal model is proposed, which can be easily characterized from FEM simulations and can acquire the critical...
Enrichment of trace metals in water utilizing the coagulation of soybean protein
International Nuclear Information System (INIS)
Musha, Soichiro; Takahashi, Yoshihisa.
1975-01-01
An enrichment of trace metals in water with a coagulated soybean protein and the complex-forming character of heavy metal ions with the soybean protein were investigated by means of emission spectrography. Fixed amounts of soybean milk (collector) and delta-gluconic lactone (coagulant) were added to a sample solution containing various metal ions, and then the mixture was heated to boiling in order to coagulate the protein. The coagulum (soybean curd) separated from the suspension with a centrifuge was burned to ashes with a low temperature plasma asher. Then metals enriched in the soybean curd were determined by means of emission spectrography. The pH of the solution was adjusted to 4.4--5.0 by adding suitable amounts of delta-gluconic lactone for the complete coagulation of the soybean protein. The proposed method can be applied to the collection and enrichment of various metal ions such as gold, silver, mercury, platinum, cadmium, beryllium, palladium, antimony, gallium, indium, cerium, lanthanum, thorium, yttrium, zirconium, etc. Those metals are not detectable in the original soybean. (auth.)
Characterization of Natural Organic Matter by FeCl3 Coagulation
Cahyonugroho, O. H.; Hidayah, E. N.
2018-01-01
Natural organic matter (NOM) is heterogenous mixture of organic compounds that enter the water from various decomposition and metabolic reactions, including animal, plant, domestic and industrial wastes. NOM refers to group of carbon-based compounds that are found in surface water and ground water. The aim of the study is to assess organic matter characteristics in Jagir River as drinking water source and to characterize the organic components that could be removed during coagulation. Coagulation is the common water treatment process can be used to remove NOM with FeCl3 coagulant in various dosage. NOM surrogates, including total organic carbon (TOC), ultraviolet absorbance at 254 nm (UV254) and specific UV absorbance (SUVA) were chosen to assess the organic removal. Results of jar test experiments showed that NOM can be removed about 40% of NOM surrogates with 200 mg/L FeCl3. About 60% removal of total organic fraction, which is mainly humic substances, as detected by size exclusion chromatography (SEC).
Changes in Chara hispida L. morphology in response to phosphate aluminium coagulant application
Directory of Open Access Journals (Sweden)
Rybak Michał
2018-03-01
Full Text Available Progressing eutrophication of waterbodies requires measures to be undertaken that aim at halting or reversing negative changes in the environment. Chemical restoration is one of the most common methods used for lake treatment, where iron or aluminium phosphate coagulants are applied. However, their chemical qualities pose the risk of acidification and aluminium ion release, which become toxic in acidic conditions. The influence of coagulants on aquatic plants, including charophytes that are very valuable from the ecological perspective, is little recognised. For this reason, the aim of the research was to define changes in the growth pattern of the charophyte Chara hispida under the influence of an aluminium coagulant. The research was carried out in mesocosms (0.8 m3 located in situ in a lake. Polyaluminium chloride was applied once to each chamber in doses of 50.0, 100.0 and 200.0 ml m−3. Coagulant concentrations reflected aggressive restoration aimed at precipitation of phosphates, suspension and water colour at the same time. It was proved that the coagulant had inhibited the growth and slightly reduced the length of branchlets, and simultaneously elongated internode cells. Changes in the total length as well as the length of branchlets were caused by a strong pH decrease of the environment which simultaneously induced higher aluminium solubility and toxicity. Elongation of internode cells was caused by reduced light availability, resulting from high water turbidity in the first stage of coagulant’s application, and then from the charophytes’ thallus being covered by a coagulated suspension precipitated from water.
International Nuclear Information System (INIS)
Salama, D.H.
2008-01-01
The environmental risk factors related to the breast tumors (lumps) are essential in order to build strategies to decrease cancer incidence and mortality among different socioeconomic and cultural backgrounds. A case control study of 70 cases and 52 controls were classified into high, middle and low socioeconomic classes. The results revealed significant increased risk of breast tumors among working females, having positive family history, married with lower mean parity, with higher consumption of fatty meals, lesser meat intake. Non significant risk factors were the social class, exposure to ionizing radiation, non lactating. wearing tight bra, consumption of vegetables and fruits, oral contraceptive pill users and exposure to outdoor air pollution or indoor pollution as floors and wall paintings. In conclusion, this study highlights the positive life style for egyptian women so they can prevent some of the environmental risks of breast tumors. Increasing the awareness of breast diseases and regular examination remains the corner stone for early detection management of breast lumps.
Coagulation Factor Tests: MedlinePlus Lab Test Information
... K. Brunner & Suddarth's Handbook of Laboratory and Diagnostic Tests. 2nd Ed, Kindle. Philadelphia: Wolters Kluwer Health, Lippincott Williams & Wilkins; c2014. Coagulation Factor Assay; 156–7 p. ...
DEFF Research Database (Denmark)
Bladbjerg, E-M; Gram, J; Jespersen, J
2000-01-01
Ever since the coagulant activity of blood coagulation factor VII (FVII:C) was identified as a risk indicator of cardiac death, a large number of studies have measured FVII protein concentrations in plasma. FVII protein concentrations are either measured immunologically with an ELISA method (FVII...
Coagulation and flocculation in the preparation of drinking water in a pilot plant
Directory of Open Access Journals (Sweden)
Iličić Gordana
2005-01-01
Full Text Available The objective of the practical part in this article was to explore the influence of different parameters on coagulation and flocculation processes as well as the influence of this stage on other stages in water purification. Analysis of the water samples was conducted in the chemical laboratory of Banja Luka Municipal Waterworks using standard methods for analyzing drinking water. The results are presented as diagrams that show the dependence of different parameters as a function of the residual turbidity and the content of natural organic matters in water. The following conclusions were drawn It is necessary to conduct the chemical treatment of raw water with the aim to satisfy chemical and bacteriological standards for drinking water. The best results were achieved with Al2(SO4s as coagulant,. Counterrecoil sludge in an amount of 2-3% in relation with the total quantity of water has a positive impacts on coagulation-flocculation processes. 4. For effective purification, all the conditions for coagulation-flocculation must be adjusted for the filter to have a longer useful life. One of example is correction of the pH to pH=7, coagulant dose 20 mg/L Al2(SO4s, flocculant dose 0.1 mg/L PE, counterrecoil sludge dose 90 L/h PM.
Li, Sheng; Lee, Shang-Tse; Sinha, Shahnawaz; Leiknes, TorOve; Amy, Gary L.; Ghaffour, NorEddine
2016-01-01
This study investigated the impact of coagulation on the transformation between colloidal and particulate transparent exopolymer particles (TEP) in seawater; and the effectiveness of a combined pretreatment consisting of coagulation and UF on minimizing TEP fouling of seawater reverse osmosis (SWRO) membranes. Coagulation with ferric chloride at pH 5 substantially transformed colloidal TEP (0.1–0.4) into particulate TEP (>0.4) leading to a better membrane fouling control. Both 50 and 100 kDa molecular weight cut-off (MWCO) UF membranes removed most of particulate and colloidal TEP without the assistance of coagulation, but coagulation is still necessary for better UF fouling control. The improvement of combined SWRO pretreatment with coagulation and 50 kDa UF membranes was not that much significant compared to UF pretreatment with 50 KDa alone. Therefore, the minimal coagulant dosage for seawater containing TEP should be based on the UF fouling control requirements rather than removal efficiency. © 2016 Elsevier Ltd
Li, Sheng
2016-07-02
This study investigated the impact of coagulation on the transformation between colloidal and particulate transparent exopolymer particles (TEP) in seawater; and the effectiveness of a combined pretreatment consisting of coagulation and UF on minimizing TEP fouling of seawater reverse osmosis (SWRO) membranes. Coagulation with ferric chloride at pH 5 substantially transformed colloidal TEP (0.1–0.4) into particulate TEP (>0.4) leading to a better membrane fouling control. Both 50 and 100 kDa molecular weight cut-off (MWCO) UF membranes removed most of particulate and colloidal TEP without the assistance of coagulation, but coagulation is still necessary for better UF fouling control. The improvement of combined SWRO pretreatment with coagulation and 50 kDa UF membranes was not that much significant compared to UF pretreatment with 50 KDa alone. Therefore, the minimal coagulant dosage for seawater containing TEP should be based on the UF fouling control requirements rather than removal efficiency. © 2016 Elsevier Ltd
Lumped parameter modeling of a two-phase thermal-hydraulic channel with interface tracking
International Nuclear Information System (INIS)
Jo, J.H.; Kaufman, J.M.; Ruger, C.J.; Stein, S.
1978-01-01
A nonhomogenous, thermal nonequilibrium model for one-dimensional two-phase flow in a heated channel has been formulated in lumped parameter form. The channel is divided into a variable number of flow regimes separated by moving interfaces. The model can be used to predict the behavior of a LWR core and both primary and secondary sides of a steam generator under transient conditions. (author)
International Nuclear Information System (INIS)
Baup, Olivier
2001-01-01
The aim of this work was to study the TIG multipass welding process on stainless steel, by means of numerical methods and then to work out simplified and bead lumping methods in order to reduce adjusting and realisation times of these calculations. A simulation was used as reference for the validation of these methods; after the presentation of the test series having led to the option choices of this calculation (2D generalised plane strains, elastoplastic model with an isotropic hardening, hardening restoration due to high temperatures), various simplifications were tried on a plate geometry. These simplifications related various modelling points with a correct plastic flow representation in the plate. The use of a reduced number of thermal fields characterising the bead deposit and a low number of tensile curves allow to obtain interesting results, decreasing significantly the Computing times. In addition various lumping bead methods have been studied and concerning both the shape and the thermic of the macro-deposits. The macro-deposit shapes studied are in 'L', or in layer or they represent two beads one on top of the other. Among these three methods, only those using a few number of lumping beads gave bad results since thermo-mechanical history was deeply modified near and inside the weld. Thereafter, simplified methods have been applied to a tubular geometry. On this new geometry, experimental measurements were made during welding, which allow a validation of the reference calculation. Simplified and reference calculations gave approximately the same stress fields as found on plate geometry. Finally, in the last part of this document a procedure for automatic data setting permitting to reduce significantly the calculation phase preparation is presented. It has been applied to the calculation of thick pipe welding in 90 beads; the results are compared with a simplified simulation realised by Framatome and with experimental measurements. A bead by
Change of particle size distribution during Brownian coagulation
International Nuclear Information System (INIS)
Lee, K.W.
1984-01-01
Change in particle size distribution due to Brownian coagulation in the continuum regime has been stuied analytically. A simple analytic solution for the size distribution of an initially lognormal distribution is obtained based on the assumption that the size distribution during the coagulation process attains or can, at least, be represented by a time dependent lognormal function. The results are found to be in a form that corrects Smoluchowski's solution for both polydispersity and size-dependent kernel. It is further shown that regardless of whether the initial distribution is narrow or broad, the spread of the distribution is characterized by approaching a fixed value of the geometric standard deviation. This result has been compared with the self-preserving distribution obtained by similarity theory. (Author)
The effects of nanomaterials on blood coagulation in hemostasis and thrombosis.
Simak, Jan; De Paoli, Silvia
2017-09-01
The blood coagulation balance in the organism is achieved by the interaction of the blood platelets (PLTs) with the plasma coagulation system (PCS) and the vascular endothelial cells. In healthy organism, these systems prevent thrombosis and, in events of vascular damage, enable blood clotting to stop bleeding. The dysregulation of hemostasis may cause serious thrombotic and/or hemorrhagic pathologies. Numerous engineered nanomaterials are being investigated for biomedical purposes and are unavoidably exposed to the blood. Also, nanomaterials may access vascular system after occupational, environmental, or other types of exposure. Thus, it is essential to evaluate the effects of engineered nanomaterials on hemostasis. This review focuses on investigations of nanomaterial interactions with the blood components involved in blood coagulation: the PCS and PLTs. Particular emphases include the pathophysiology of effects of nanomaterials on the PCS, including the kallikrein-kinin system, and on PLTs. Methods for investigating these interactions are briefly described, and a review of the most important studies on the interactions of nanomaterials with plasma coagulation and platelets is provided. WIREs Nanomed Nanobiotechnol 2017, 9:e1448. doi: 10.1002/wnan.1448 For further resources related to this article, please visit the WIREs website. © Published 2017. This article is a U.S. Government work and is in the public domain in the USA.
Van Dyke, Michael B.
2013-01-01
Present preliminary work using lumped parameter models to approximate dynamic response of electronic units to random vibration; Derive a general N-DOF model for application to electronic units; Illustrate parametric influence of model parameters; Implication of coupled dynamics for unit/board design; Demonstrate use of model to infer printed wiring board (PWB) dynamics from external chassis test measurement.
Commonly Used Dietary Supplements on Coagulation Function during Surgery
Directory of Open Access Journals (Sweden)
Chong-Zhi Wang
2015-07-01
Full Text Available Background: Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods: Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results: Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins. Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions: To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet
Commonly Used Dietary Supplements on Coagulation Function during Surgery
Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su
2015-01-01
Abstract Background Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information about the potential complications of dietary supplements during perioperative management is important for physicians. Methods Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Results Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John’s wort, and valerian) and four other dietary supplements (coenzyme Q10, glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John’s wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. Conclusions To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are
Commonly Used Dietary Supplements on Coagulation Function during Surgery.
Wang, Chong-Zhi; Moss, Jonathan; Yuan, Chun-Su
2015-09-01
Patients who undergo surgery appear to use dietary supplements significantly more frequently than the general population. Because they contain pharmacologically active compounds, dietary supplements may affect coagulation and platelet function during the perioperative period through direct effects, pharmacodynamic interactions, and pharmacokinetic interactions. However, in this regard, limited studies have been conducted that address the pharmacological interactions of dietary supplements. To avoid possible bleeding risks during surgery, information of potential complications of dietary supplements during perioperative management is important for physicians. Through a systematic database search of all available years, articles were identified in this review if they included dietary supplements and coagulation/platelet function, while special attention was paid to studies published after 1990. Safety concerns are reported in commercially available dietary supplements. Effects of the most commonly used natural products on blood coagulation and platelet function are systematically reviewed, including 11 herbal medicines (echinacea, ephedra, garlic, ginger, ginkgo, ginseng, green tea, kava, saw palmetto, St John's wort, and valerian) and 4 other dietary supplements (coenzyme Q 10 , glucosamine and chondroitin sulfate, fish oil, and vitamins). Bleeding risks of garlic, ginkgo, ginseng, green tea, saw palmetto, St John's wort, and fish oil are reported. Cardiovascular instability was observed with ephedra, ginseng, and kava. Pharmacodynamic and pharmacokinetic interactions between dietary supplements and drugs used in the perioperative period are discussed. To prevent potential problems associated with the use of dietary supplements, physicians should be familiar with the perioperative effects of commonly used dietary supplements. Since the effects of dietary supplements on coagulation and platelet function are difficult to predict, it is prudent to advise their
Effects of coagulating enzyme types (commercial calf rennet ...
African Journals Online (AJOL)
Effects of coagulating enzyme types (commercial calf rennet, Aspergillus niger var. awamori as recombinant chymosin and rhizomucor miehei as microbial rennet) on the chemical and sensory characteristics of white pickled cheese.
Naceradska, Jana; Pivokonsky, Martin; Pivokonska, Lenka; Baresova, Magdalena; Henderson, Rita K; Zamyadi, Arash; Janda, Vaclav
2017-05-01
The study investigates the effect of permanganate pre-oxidation on the coagulation of peptides/proteins of Microcystis aeruginosa which comprise a major proportion of the organic matter during cyanobacterial bloom decay. Four different permanganate dosages (0.1, 0.2, 0.4 and 0.6 mg KMnO 4 mg -1 DOC) were applied prior to coagulation by ferric sulphate. Moreover, changes in sample characteristics, such as UV 254 , DOC content and molecular weight distribution, after pre-oxidation were monitored. The results showed that permanganate pre-oxidation led to a reduction in coagulant dose, increased organic matter removals by coagulation (by 5-12% depending on permanganate dose), microcystin removal (with reductions of 91-96%) and a shift of the optimum pH range from 4.3 to 6 without to 5.5-7.3 with pre-oxidation. Degradation of organic matter into inorganic carbon and adsorption of organic matter onto hydrous MnO 2 are suggested as the main processes responsible for coagulation improvement. Moreover, permanganate prevented the formation of Fe-peptide/protein complexes that inhibit coagulation at pH about 6.2 without pre-oxidation. The study showed that carefully optimized dosing of permanganate improves cyanobacterial peptide/protein removal, with the benefit of microcystin elimination. Copyright © 2017 Elsevier Ltd. All rights reserved.
The mechanism and properties of acid-coagulated milk gels
Directory of Open Access Journals (Sweden)
Chanokphat Phadungath
2005-03-01
Full Text Available Acid-coagulated milk products such as fresh acid-coagulated cheese varieties and yogurt areimportant dairy food products. However, little is known regarding the mechanisms involved in gel formation, physical properties of acid gels, and the effects of processing variables such as heat treatment and gelation temperature on the important physical properties of acid milk gels. This paper reviews the modern concepts of possible mechanisms involved in the formation of particle milk gel aggregation, along with recent developments including the use of techniques such as dynamic low amplitude oscillatory rheology to observe the gel formation process, and confocal laser scanning microscopy to monitor gel microstructure.
EVALUATION OF PERIODONTAL TISSUES CONDITION IN CHILDREN WITH BLOOD COAGULABILITY PATHOLOGY
Directory of Open Access Journals (Sweden)
M. A. Gavrilenko
2013-12-01
Full Text Available Background. Actuality of the problem is determined by the high prevalence of inflammatory diseases of periodontal tissues in children with blood pathology (100%. Primary prevention of dental caries and periodontal diseases has the exceptional importance in the dentist’s work with children who have blood coagulability disorders. Prevention of dental diseases of the oral cavity in this category of patients has a number of features because there is the risk of bleeding during both home oral hygiene and professional hygiene. Exogenous prevention (fluoride-containing gels, varnishes, solutions, sealants also has its own peculiarities in these children. On the other hand, the impossibility of preventive measures implementation is the significant factor in the pathogenesis of gingivitis and subsequently periodontitis in children with disorders of blood coagulability. Aim. To examine the status of oral hygiene in children with blood coagulability disorders. To examine the severity of inflammatory and destructive changes in the periodontal tissues in children with disorders of blood coagulability. To investigate timing and frequency of oral hygiene implementation in children with disorders of blood coagulability. To reveal the interrelations between the intensity, prevalence of periodontal tissues disorders in children with blood coagulability pathology and the periods of tooth development, taking into account the influence of risk factors and frequency of oral hygiene. Materials and methods. 120 children between 2 and 18 years old with blood coagulability disorders (hemophilia A, B, thrombocytopenia, thrombocytopathy were examined. Children were divided into following age groups: I – 2-5 years old (40 children, II – 6-10 years old (40 children, III – 11-18 years old (40 children, according to the periods of tooth development, with an equal number of children in groups according to diagnoses. Hygiene index value was determined according to
Evaluation of periodontal tissues condition in children with blood coagulability pathology
Directory of Open Access Journals (Sweden)
M. A. Gavrilenko
2013-12-01
Full Text Available Background. Actuality of the problem is determined by the high prevalence of inflammatory diseases of periodontal tissues in children with blood pathology (100%. Primary prevention of dental caries and periodontal diseases has the exceptional importance in the dentist’s work with children who have blood coagulability disorders. Prevention of dental diseases of the oral cavity in this category of patients has a number of features because there is the risk of bleeding during both home oral hygiene and professional hygiene. Exogenous prevention (fluoride-containing gels, varnishes, solutions, sealants also has its own peculiarities in these children. On the other hand, the impossibility of preventive measures implementation is the significant factor in the pathogenesis of gingivitis and subsequently periodontitis in children with disorders of blood coagulability. Aim.To examine the status of oral hygiene in children with blood coagulability disorders.To examine the severity of inflammatory and destructive changes in the periodontal tissues in children with disorders of blood coagulability. To investigate timing and frequency of oral hygiene implementation in children with disorders of blood coagulability. To reveal the interrelations between the intensity, prevalence of periodontal tissues disorders in children with blood coagulability pathology and the periods of tooth development, taking into account the influence of risk factors and frequency of oral hygiene. Materials and methods. 120 children between 2 and 18 years old with blood coagulability disorders (hemophilia A, B, thrombocytopenia, thrombocytopathy were examined. Children were divided into following age groups: I – 2-5 years old (40 children, II – 6-10 years old (40 children, III – 11-18 years old (40 children, according to the periods of tooth development, with an equal number of children in groups according to diagnoses. Hygiene index value was determined according to Fedorov
Influence of ionizing radiation and 12-crown-4 on coagulation system components of rat blood
International Nuclear Information System (INIS)
Kratenko, R.Yi.
2006-01-01
The influence of 12-crown-4 and ionizing radiation on some components of blood coagulation system: Ca 2+ contents and prostaglandin concentrations in the blood serum, and erythrocyte contents in the blood plasma are studied. The influence of 12-crown-4 and ionizing radiation increases the coagulational properties of erythrocytes. The synergism of ionizing irradiation and 12-crown-4 influence blood coagulation process points out at the occurrence of radiomimetic properties of the latter
Jang, Min; Lee, Hyun-Ju; Shim, Yonsik
2010-04-01
The processes of coagulation and flocculation using high molecular weight long-chain polymers were applied to treat mine water having fine flocs of which about 93% of the total mass was less than 3.02 microm, representing the size distribution of fine particles. Six different combinations of acryl-type anionic flocculants and polyamine-type cationic coagulants were selected to conduct kinetic tests on turbidity removal in mine water. Optimization studies on the types and concentrations of the coagulant and flocculant showed that the highest rate of turbidity removal was obtained with 10 mg L(-1) FL-2949 (coagulant) and 12 mg L(-1) A333E (flocculant), which was about 14.4 and 866.7 times higher than that obtained with A333E alone and that obtained through natural precipitation by gravity, respectively. With this optimized condition, the turbidity of mine water was reduced to 0 NTU within 20 min. Zeta potential measurements were conducted to elucidate the removal mechanism of the fine particles, and they revealed that there was a strong linear relationship between the removal rate of each pair of coagulant and flocculant application and the zeta potential differences that were obtained by subtracting the zeta potential of flocculant-treated mine water from the zeta potential of coagulant-treated mine water. Accordingly, through an optimization process, coagulation-flocculation by use of polymers could be advantageous to mine water treatment, because the process rapidly removes fine particles in mine water and only requires a small-scale plant for set-up purposes owing to the short retention time in the process.
Pretreatment of palm oil mill effluent (POME) using Moringa oleifera seeds as natural coagulant.
Bhatia, Subhash; Othman, Zalina; Ahmad, Abdul Latif
2007-06-25
Moringa oleifera seeds, an environmental friendly and natural coagulant are reported for the pretreatment of palm oil mill effluent (POME). In coagulation-flocculation process, the M. oleifera seeds after oil extraction (MOAE) are an effective coagulant with the removal of 95% suspended solids and 52.2% reduction in the chemical oxygen demand (COD). The combination of MOAE with flocculant (NALCO 7751), the suspended solids removal increased to 99.3% and COD reduction was 52.5%. The coagulation-flocculation process at the temperature of 30 degrees C resulted in better suspended solids removal and COD reduction compared to the temperature of 40, 55 and 70 degrees C. The MOAE combined with flocculant (NALCO 7751) reduced the sludge volume index (SVI) to 210mL/g with higher recovery of dry mass of sludge (87.25%) and water (50.3%).
Metastatic uterine leiomyosarcoma presenting as a breast lump.
LENUS (Irish Health Repository)
Sibartie, S
2009-01-31
BACKGROUND: It is uncommon to encounter a breast metastasis from an extramammary malignancy and even rarer from a uterine leiomyosarcoma. AIMS: We describe the third case report in the medical literature of a breast metastasis from a uterine leiomyosarcoma. METHODS: We report the management of a 56-year-old patient who presented with a breast lump 3 years after hysterectomy for a fibroid uterus. We conducted a literature review of breast leiomyosarcomas. RESULTS: The excision of the breast mass revealed a low-grade leiomyosarcoma. Radiographic examinations demonstrated metastases to the lung, liver, pelvis and bone. Retrospective pathology review of her uterus identified a small focus of leiomyosarcoma. She received chemotherapy and palliative radiotherapy but passed away within few months. CONCLUSION: Metastasis to the breast from a non-breast primary is generally a sign of disseminated disease and; thus, a poor prognostic indicator.
Does whole blood coagulation analysis reflect developmental haemostasis?
DEFF Research Database (Denmark)
Ravn, Hanne Berg; Andreasen, Jo Bønding; Hvas, Anne-Mette
2017-01-01
.05), but there was no sign of developmental changes in whole blood coagulation assessment when applying ROTEM, apart from clotting time in the EXTEM assay (P reach statistical significance. Citrate-anticoagulated blood showed...
Study of Pellets and Lumps as Raw Materials in Silicon Production from Quartz and Silicon Carbide
Dal Martello, E.; Tranell, G.; Gaal, S.; Raaness, O. S.; Tang, K.; Arnberg, L.
2011-10-01
The use of high-purity carbon and quartz raw materials reduces the need for comprehensive refining steps after the silicon has been produced carbothermically in the electric reduction furnace. The current work aims at comparing the reaction mechanisms and kinetics occurring in the inner part of the reduction furnace when pellets or lumpy charge is used, as well as the effect of the raw material mix. Laboratory-scale carbothermic reduction experiments have been carried out in an induction furnace. High-purity silicon carbide and two different high-purity hydrothermal quartzes were charged as raw materials at different molar ratios. The charge was in the form of lumps (size, 2-5 mm) or as powder (size, 10-20 μm), mixed and agglomerated as pellets (size, 1-3 mm) and reacted at 2273 K (2000 °C). The thermal properties of the quartzes were measured also by heating a small piece of quartz in CO atmosphere. The investigated quartzes have different reactivity in reducing atmosphere. The carbothermal reduction experiments show differences in the reacted charge between pellets and lumps as charge material. Solid-gas reactions take place from the inside of the pellets porosity, whereas reactions in lumps occur topochemically. Silicon in pellets is produced mainly in the rim zone. Larger volumes of silicon have been found when using lumpy charge. More SiO is produced when using pellets than for lumpy SiO2 for the same molar ratio and heating conditions. The two SiC polytypes used in the carbothermal reduction experiments as carbon reductants presented different reactivity.
Perdigón-Melón, J A; Carbajo, J B; Petre, A L; Rosal, R; García-Calvo, E
2010-09-15
A coupled coagulation-Fenton process was applied for the treatment of cosmetic industry effluents. In a first step, FeSO(4) was used as coagulant and the non-precipitated Fe(2+) remaining in dissolution was used as catalyst in the further Fenton process. In the coagulation process a huge decrease in total organic carbon (TOC) was achieved, but the high concentration of phenol derivatives was not diminished. The decrease in TOC in the coagulation step significantly reduces the amount of H(2)O(2) required in the Fenton process for phenol depletion. The coupled process, using a H(2)O(2) dose of only 2 g l(-1), reduced TOC and total phenol to values lower than 40 and 0.10 mg l(-1), respectively. The short reaction period (less than 15 min) in TOC and phenol degradation bodes well for improving treatment in a continuous regime. The combination of both processes significantly reduced the ecotoxicity of raw effluent and markedly increased its biodegradability, thus allowing easier treatment by the conventional biological units in conventional sewage treatment plants (STPs). Copyright 2010 Elsevier B.V. All rights reserved.
Ultrasound imaging of Nd:YAG laser-induced tissue coagulation in porcine livers.
Ritzel, U; Wietzke-Braun, P; Brinck, U; Leonhardt, U; Ramadori, G
2001-12-01
Absorption of laser light energy induces denaturation of proteins and thermocoagulation of irradiated tissue. Recently, MRI-guided laser coagulation in combination with MR thermometry was reported as a treatment of liver tumours. In the present study ultrasonographic imaging was evaluated for its suitability in laser induced tissue thermocoagulation. Fresh porcine livers were used for ex vivo examinations. Placement of the laser catheter and tissue coagulation during laser light emission were online monitored by ultrasonography. Nd:YAG laser-induced tissue damage was evaluated by macroscopical and microscopical examinations of histological sections. During laser light emission a marked hyperdense signal enhancement was observed by ultrasonography which strongly correlated with the extent of macroscopic tissue damage. The size of laser-induced coagulation zone depended on both the power setting and total energy delivered. Carbonization of the tissue surrounding the laser tip is a limiting factor because of laser light absorption. However our data indicate that using appropriate laser energy and exposure time prevent carbonization although carbonization can not be visualized by ultrasonography. It is concluded from the present ex vivo studies that laser coagulation can be effectively performed under ultrasonographic guidance.
Extraction of natural coagulant from peanut seeds for treatment of turbid water
International Nuclear Information System (INIS)
Birima, A H; Desa, M N M; Muda, Z C; Hammad, H A
2013-01-01
This study investigates the potential of peanut seeds as an environmental friendly and natural coagulant for the treatment of high turbid water. The peanut seeds have been used after oil extraction; and the active coagulation component was extracted by distilled water and salt solution of different salt concentrations. The salts used were NaCl, KNO 3 , KCl, NH 4 Cl and NaNO 3 . Synthetic water with 200 NTU turbidity was used. Peanut extracted with NaCl (PC-NaCl) could effectively remove 92% of the 200 NTU turbidity using only 20 mg/l, while peanut seeds extracted with distilled water (PC-DW) could remove only 31.5% of the same turbidity with the same dosage. The coagulant dosage did not affected by the concentration of the salt solution, however, residual turbidity decreased with increasing the concentration of the salt; and the relationship was found to be a second order polynomial curve with R 2 of 0.9312. The other salts tested were also found to be good solvents to extract the active coagulation component with no much difference from NaCl solution in terms of efficiency.
SYSTEM OF PRECISE DOSING OF COAGULANT IN THE PULVERIZING AERATOR POWERED BY WIND USING FUZZY LOGIC
Directory of Open Access Journals (Sweden)
Andrzej Osuch
2017-06-01
Full Text Available One of the methods used to support land restoration lakes is the method of pulverizing aeration. Use of aerators powered exclusively by wind improves the condition of reservoirs, while not compromising the environment. The pulverizing aeration process drive is windy on the water aeration zone near bottom, while removing harmful gases anaerobic metabolism. Aerators of this type due to the unique method of operation also enable dosing of inactivation coagulants with oxygenated water to the depths of the lake. Mileage coagulant dosing can be made dependent on the speed of the wind, which has an impact on the performance of his work, because with the increase of wind speed dispensing valve coagulants should be stronger open. One of the methods for assessing the state of lakes is to measure water transparency. The softer visibility, the most likely state of the water is better. Dosage of coagulant so you can make the transparency of the water. Similarly, with increasing transparency water dispensing valve should be more covered up. Control of the drain valve dispenser coagulant can be simultaneously dependent on two factors. The study was designed method of control drain valve dispenser coagulant using fuzzy inference.
Studies on Removal of Dyes from wastewater using Electro-coagulation Process
N B. Patel; B D. Soni; J P. Ruparelia
2000-01-01
Electro-coagulation (EC) is one of the effective techniques to remove colour, COD and organic compounds from wastewater. In this paper electro coagulation technique has been used for the removal of colour and COD from dye solutions containing Direct Black 22 and Acid Red 97 using batch process. For batch the process effect of operational parameters such as current density, initial pH of the solution, time of electrolysis and electrode materials were studied to attempt max...
Gumińska, Jolanta; Kłos, Marcin
2015-01-01
Filtration efficiency in a conventional water treatment system was analyzed in the context of pre-hydrolyzed coagulant overdosing. Two commercial coagulants of different aluminum speciation were tested. A study was carried out at a water treatment plant supplied with raw water of variable quality. The lack of stability of water quality caused many problems with maintaining the optimal coagulant dose. The achieved results show that the type of coagulant had a very strong influence on the effectiveness of filtration resulting from the application of an improper coagulant dose. The overdosing of high basicity coagulant (PAC85) caused a significant increase of fine particles in the outflow from the sedimentation tanks, which could not be retained in the filter bed due to high surface charge and the small size of hydrolysis products. When using a coagulant of lower basicity (PAC70), it was much easier to control the dose of coagulant and to adjust it to the changing water quality.
Directory of Open Access Journals (Sweden)
Antov Mirjana G.
2007-01-01
Full Text Available Investigation of an extraction procedure of protein coagulants from common bean seed regarding concentration of NaCl and pH was performed. High values of protein concentration and coagulation activity in crude extract (9.19 g/l and 23.9%, respectively were obtained when the extraction was performed using 0.5 mol/l NaCl and water as solvent, which represents an advantage for economic and environmental reasons. Crude extract of common bean seed was purified by precipitation at two different percentages of (NH42SO4 saturation, followed by batch ion-exchange chromatography. The highest obtained coagulation activity, 45%, was determined in fraction that was eluated at 1.75 mol/l NaCl from resin loaded with proteins precipitated upon 80-100% (NH42SO4 saturation. High values of coagulation activity showed by some eluates suggest their application as natural coagulant for water purification. .
Enzymatic lipid oxidation by eosinophils propagates coagulation, hemostasis, and thrombotic disease
Uderhardt, Stefan; Ackermann, Jochen A.; Fillep, Tobias; Hammond, Victoria J.; Willeit, Johann; Stark, Konstantin; Rossaint, Jan; Schubert, Irene; Mielenz, Dirk; Dietel, Barbara; Raaz-Schrauder, Dorette; Ay, Cihan; Thaler, Johannes; Heim, Christian; Collins, Peter W.; Schabbauer, Gernot; Mackman, Nigel; Voehringer, David; Nadler, Jerry L.; Lee, James J.; Massberg, Steffen; Rauh, Manfred; O’Donnell, Valerie B.
2017-01-01
Blood coagulation is essential for physiological hemostasis but simultaneously contributes to thrombotic disease. However, molecular and cellular events controlling initiation and propagation of coagulation are still incompletely understood. In this study, we demonstrate an unexpected role of eosinophils during plasmatic coagulation, hemostasis, and thrombosis. Using a large-scale epidemiological approach, we identified eosinophil cationic protein as an independent and predictive risk factor for thrombotic events in humans. Concurrent experiments showed that eosinophils contributed to intravascular thrombosis by exhibiting a strong endogenous thrombin-generation capacity that relied on the enzymatic generation and active provision of a procoagulant phospholipid surface enriched in 12/15-lipoxygenase–derived hydroxyeicosatetraenoic acid–phosphatidylethanolamines. Our findings reveal a previously unrecognized role of eosinophils and enzymatic lipid oxidation as regulatory elements that facilitate both hemostasis and thrombosis in response to vascular injury, thus identifying promising new targets for the treatment of thrombotic disease. PMID:28566277
Effects of coagulating enzyme types (commercial calf rennet ...
African Journals Online (AJOL)
Aysegul
2013-09-11
clotting enzyme in traditional cheese-making world- wide (Fox, 1987 ... Following pre-brining, the cheeses were packaged in plastic cups (1 kg) containing ..... study the differential degradation of αs-casein by various coagulants.
Coagulation system changes associated with susceptibility to infection in trauma patients.
Cole, Elaine; Davenport, Ross; De'Ath, Henry; De-Ath, Henry; Manson, Joanna; Brockamp, Thomas; Brohi, Karim
2013-01-01
Infection following trauma is associated with increased morbidity and mortality and is common following severe hemorrhage. There is a strong interaction between the coagulation and immunity. The objective of this study was to establish if there was an association between changes in coagulation status after hemorrhage and the subsequent incidence of infection. Prospective cohort study of adult injured patients presenting to a major trauma center during a 2-year period. Blood was drawn at 24 hours following admission and analyzed using functional thromboelastography testing and laboratory defined tests of coagulation and blood count. Patients were followed up for infectious episodes while in the hospital using Center for Disease Control definitions. A total of 158 patients were recruited; 71 (45%) developed infection and were older (44 years vs. 32 years, p = 0.01) and more severely injured (Injury Severity Score [ISS], 25 vs.10; p < 0.01). White blood cell counts at 24 hours were normal, and there was no difference between groups (both 9.6 × 10/(9)L). Protein C was lower in those with infection (70.2 IU/dL vs. 83.3 IU/dL, p = 0.02), with a dose-dependent increase in infection as levels of protein C decreased. Plasmin activation at 24 hours was also strongly associated with infection plasmin-antiplasmin (infection vs. no infection, 6,156 μg/L vs. 3,324 μg/L, p = 0.03). The infection cohort had overall 12% lower procoagulant levels (varied between factor VIII 6.4% and factor II 16.2%). There is a strong association between the status of the coagulation system after 24 hours and the development of infection following trauma. Improved early coagulation management may decrease infection rates in this patient group. Prognostic prospective study, level III.
International Nuclear Information System (INIS)
Li Xiao-Dong; Lin Zhen-Quan; Song Mei-Xia; Ke Jian-Hong
2010-01-01
We propose a kinetic aggregation model where species A aggregates evolve by the catalysis-coagulation and the catalysis-fragmentation, while the catalyst aggregates of the same species B or C perform self-coagulation processes. By means of the generalized Smoluchowski rate equation based on the mean-field assumption, we study the kinetic behaviours of the system with the catalysis-coagulation rate kernel K(i,j;l) ∝ l ν and the catalysis-fragmentation rate kernel F(i,j;l) ∝ l μ , where l is the size of the catalyst aggregate, and ν and μ are two parameters reflecting the dependence of the catalysis reaction on the size of the catalyst aggregate. The relation between the values of parameters ν and μ reflects the competing roles between the two catalysis processes in the kinetic evolution of species A. It is found that the competing roles of the catalysis-coagulation and catalysis-fragmentation in the kinetic aggregation behaviours are not determined simply by the relation between the two parameters ν and μ, but also depend on the values of these two parameters. When ν > μ and ν ≥ 0, the kinetic evolution of species A is dominated by the catalysis-coagulation and its aggregate size distribution a k (t) obeys the conventional or generalized scaling law; when ν k (t) approaches the scale-free form; and in other cases, a balance is established between the two competing processes at large times and a k (t) obeys a modified scaling law. (cross-disciplinary physics and related areas of science and technology)
Treatment of Surface water in lebanon by using the coagulation-flocculation procedure
International Nuclear Information System (INIS)
SLIM, K.; Saad, Z.; Kazpard, V.; El Samarani, A.
2005-01-01
In the absence of application of environmental protection laws in Lebanon. Anthropic effluents are directly discharged in the course of rivers. More specially two coastal rivers (GHadir and Ibrahim)located near Beirut. Treatment of these surface waters is done by coagulation-flocculation process by using Al13 coagulant. The elimination of suspended matters in Ghadir and Ibrahim rivers is studied by simple jar test coupled to measurement of supernatant turbidity and sediment volume. Physical and chemical parameters of water before and after treatment are given by Atomic absorption and ion chromatography analysis. The optimal coagulation concentration of Al was defined relatively to lowest concentration of Aluminum needed for maximum turbidity removal in treated water. This study showed that hydrolysis of aluminum salts before adding to water is relevant to the use of similar quantities of Al for the coagulation-flocculation process that eliminates primarily suspended matter in river. Restabilisation is shown in all Jar tests of Ibrahim river, but not in Ghadir where buffering effect is elevated. Results also showed that waters with low turbidity request low concentration of aluminum for the destabilization process. For this, Ibrahim water treatment was found better than river Ghadir characterized by higher inputs of anthropogenic effluents in its course. In all cases, cationic exchanges with Al 1 3 polycations within the sediments caused the release of calcium and the elevation of its concentration in the supernatant. Sulfate concentration diminished continuously in supernatant after the addition of the optimal coagulation concentration of aluminum. (author)
Weighted Flow Algorithms (WFA) for stochastic particle coagulation
International Nuclear Information System (INIS)
DeVille, R.E.L.; Riemer, N.; West, M.
2011-01-01
Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.
Weighted Flow Algorithms (WFA) for stochastic particle coagulation
DeVille, R. E. L.; Riemer, N.; West, M.
2011-09-01
Stochastic particle-resolved methods are a useful way to compute the time evolution of the multi-dimensional size distribution of atmospheric aerosol particles. An effective approach to improve the efficiency of such models is the use of weighted computational particles. Here we introduce particle weighting functions that are power laws in particle size to the recently-developed particle-resolved model PartMC-MOSAIC and present the mathematical formalism of these Weighted Flow Algorithms (WFA) for particle coagulation and growth. We apply this to an urban plume scenario that simulates a particle population undergoing emission of different particle types, dilution, coagulation and aerosol chemistry along a Lagrangian trajectory. We quantify the performance of the Weighted Flow Algorithm for number and mass-based quantities of relevance for atmospheric sciences applications.
Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.
Neuro-Coagulopathy: Blood Coagulation Factors in Central Nervous System Diseases.
De Luca, Ciro; Virtuoso, Assunta; Maggio, Nicola; Papa, Michele
2017-10-12
Blood coagulation factors and other proteins, with modulatory effects or modulated by the coagulation cascade have been reported to affect the pathophysiology of the central nervous system (CNS). The protease-activated receptors (PARs) pathway can be considered the central hub of this regulatory network, mainly through thrombin or activated protein C (aPC). These proteins, in fact, showed peculiar properties, being able to interfere with synaptic homeostasis other than coagulation itself. These specific functions modulate neuronal networks, acting both on resident (neurons, astrocytes, and microglia) as well as circulating immune system cells and the extracellular matrix. The pleiotropy of these effects is produced through different receptors, expressed in various cell types, in a dose- and time-dependent pattern. We reviewed how these pathways may be involved in neurodegenerative diseases (amyotrophic lateral sclerosis, Alzheimer's and Parkinson's diseases), multiple sclerosis, ischemic stroke and post-ischemic epilepsy, CNS cancer, addiction, and mental health. These data open up a new path for the potential therapeutic use of the agonist/antagonist of these proteins in the management of several central nervous system diseases.
Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233
Advertising Pricing Models in Media Markets: Lump-Sum versus Per-Consumer Charges
Helmut Dietl; Markus Lang; Panlang Lin
2012-01-01
This paper develops a model of asymmetric competition between a pay and a free media platform. The pay media platform generates revenues from media consumers through subscription fees, while the free media platform generates revenues from charging advertisers either on a lump-sum basis (regime A) or on a per-consumer basis (regime B). We show that the free platform produces a higher advertising level and attracts more consumers in regime A than B although advertisers must pay more for ads and...
Goudeli, Eirini; Eggersdorfer, Maximilian L; Pratsinis, Sotiris E
2015-02-03
Agglomeration occurs in environmental and industrial processes, especially at low temperatures where particle sintering or coalescence is rather slow. Here, the growth and structure of particles undergoing agglomeration (coagulation in the absence of coalescence, condensation, or surface growth) are investigated from the free molecular to the continuum regime by discrete element modeling (DEM). Particles coagulating in the free molecular regime follow ballistic trajectories described by an event-driven method, whereas in the near-continuum (gas-slip) and continuum regimes, Langevin dynamics describe their diffusive motion. Agglomerates containing about 10-30 primary particles, on the average, attain their asymptotic fractal dimension, D(f), of 1.91 or 1.78 by ballistic or diffusion-limited cluster-cluster agglomeration, corresponding to coagulation in the free molecular or continuum regimes, respectively. A correlation is proposed for the asymptotic evolution of agglomerate D(f) as a function of the average number of constituent primary particles, n̅(p). Agglomerates exhibit considerably broader self-preserving size distribution (SPSD) by coagulation than spherical particles: the number-based geometric standard deviations of the SPSD agglomerate radius of gyration in the free molecular and continuum regimes are 2.27 and 1.95, respectively, compared to ∼1.45 for spheres. In the transition regime, agglomerates exhibit a quasi-SPSD whose geometric standard deviation passes through a minimum at Knudsen number Kn ≈ 0.2. In contrast, the asymptotic D(f) shifts linearly from 1.91 in the free molecular regime to 1.78 in the continuum regime. Population balance models using the radius of gyration as collision radius underestimate (up to about 80%) the small tail of the SPSD and slightly overpredict the overall agglomerate coagulation rate, as they do not account for cluster interpenetration during coagulation. In the continuum regime, when a recently developed
Performance of Solanum incunum Linnaeus as natural coagulant ...
African Journals Online (AJOL)
hope&shola
2- concentrations for the treated water conforms to the Tanzanian Standards and WHO guidelines for drinking ... that S. incunum is promising as coagulant and disinfectant product for water purification. Key words: .... light greenish blue-grey.
Oloibiri, Violet; Ufomba, Innocent; Chys, Michael; Audenaert, Wim; Demeestere, Kristof; Van Hulle, Stijn W H
2015-01-01
A major concern for landfilling facilities is the treatment of their leachate. To optimize organic matter removal from this leachate, the combination of two or more techniques is preferred in order to meet stringent effluent standards. In our study, coagulation-flocculation and ozonation are compared as pre- treatment steps for stabilized landfill leachate prior to granular activated carbon (GAC) adsorption. The efficiency of the pre treatment techniques is evaluated using COD and UVA254 measurements. For coagulation- flocculation, different chemicals are compared and optimal dosages are determined. After this, iron (III) chloride is selected for subsequent adsorption studies due to its high percentage of COD and UVA254 removal and good sludge settle-ability. Our finding show that ozonation as a single treatment is effective in reducing COD in landfill leachate by 66% compared to coagulation flocculation (33%). Meanwhile, coagulation performs better in UVA254 reduction than ozonation. Subsequent GAC adsorption of ozonated effluent, coagulated effluent and untreated leachate resulted in 77%, 53% and 8% total COD removal respectively (after 6 bed volumes). The effect of the pre-treatment techniques on GAC adsorption properties is evaluated experimentally and mathematically using Thomas and Yoon-Nelson models. Mathematical modelling of the experimental GAC adsorption data shows that ozonation increases the adsorption capacity and break through time with a factor of 2.5 compared to coagulation-flocculation.
Temperature effects on flocculation, using different coagulants.
Fitzpatrick, C S B; Fradin, E; Gregory, J
2004-01-01
Temperature is known to affect flocculation and filter performance. Jar tests have been conducted in the laboratory, using a photometric dispersion analyser (PDA) to assess the effects of temperature on floc formation, breakage and reformation. Alum, ferric sulphate and three polyaluminium chloride (PACI) coagulants have been investigated for temperatures ranging between 6 and 29 degrees C for a suspension of kaolin clay in London tap water. Results confirm that floc formation is slower at lower temperatures for all coagulants. A commercial PACl product, PAX XL 19, produces the largest flocs for all temperatures; and alum the smallest. Increasing the shear rate results in floc breakage in all cases and the flocs never reform to their original size. This effect is most notable for temperatures around 15 degrees C. Breakage, in terms of floc size reduction, is greater for higher temperatures, suggesting a weaker floc. Recovery after increased shear is greater at lower temperatures implying that floc break-up is more reversible for lower temperatures.
Directory of Open Access Journals (Sweden)
Yali Song
2015-06-01
Full Text Available Two coagulants, aluminum sulfate and ferric chloride, were tested to reduce natural organic matter (NOM as a pretreatment prior to polyvinylidene fluoride (PVDF microfiltration (MF membranes for potable water treatment. The results showed that the two coagulants exhibited different treatment performance in NOM removal. Molecular weight (MW distributions of NOM in the tested surface raw water were concentrated at 3–5 kDa and approximately 0.2 kDa. Regardless of the coagulant species and dosages, the removal of 0.2 kDa NOM molecules was limited. In contrast, NOM at 3–5 kDa were readily removed with increasing coagulant dosages. In particular, aluminum sulfate favorably removed NOM near 5 kDa, whereas ferric chloride tended to reduce 3 kDa organic substances. Although aluminum sulfate and ferric chloride could improve the flux of the ensuing MF treatment, the optimal coagulant dosages to achieve effective pretreatment were different: 2–30 mg/L for aluminum sulfate and >15 mg/L for ferric chloride. The scanning electron microscope (SEM image of the membrane-filtered coagulated raw water showed that coagulation efficiency dramatically affected membrane flux and that good coagulation properties can reduce membrane fouling.
Suleria, Hafiz Ansar Rasul; Masci, Paul P; Zhao, Kong-Nan; Addepalli, Rama; Chen, Wei; Osborne, Simone A; Gobe, Glenda C
2017-08-04
Sulphated polysaccharides with anti-thrombotic and anti-coagulant activities have been found in various marine biota. In this study, a previously characterised anti-thrombotic and anti-coagulant extract from blacklip abalone was fractionated by anion exchange chromatography (AEC), pooled (on a sulphated polysaccharide basis) and administered to Wistar rats via oral gavage (N = 8) for assessment as an oral therapeutic. To ensure that the preparation had anti-coagulant activity prior to oral administration, it was assessed in rat blood by thromboelastography (TEG) significantly increasing reaction (R) time (or time until clot formation). Following in vitro confirmation of anti-coagulant activity, 40 mg of the preparation was orally administered to rats with blood samples collected at 2, 4, and 6 h post-gavage. Assessment of all blood samples by TEG showed some prolongation of R time from 355 to 380 s after 4 h. Dosing of the post-gavage blood samples with the abalone preparation to confirm anti-thrombotic activity in vitro revealed residual anti-coagulant activity, further suggesting that oral administration did increase anti-coagulant potential in the collected blood but that bioavailability was low. Assessment of tissues and haematological parameters showed no obvious harmful effects of the abalone preparation in animals. In summary, even though oral administration of fractionated and pooled blacklip abalone extract to rats delayed clotting after 4 h, bioavailability of the preparation appeared to be low and may be more appropriate for intravenous administration as an anti-thrombotic or anti-coagulant therapeutic.
Stumpner, Elizabeth; Kraus, Tamara; Liang, Yan; Bachand, Sandra M.; Horwath, William R.; Bachand, Philip A.M.
2018-01-01
In many regions of the world, subsidence of organic rich soils threatens levee stability and freshwater supply, and continued oxidative loss of organic matter contributes to greenhouse gas production. To counter subsidence in the Sacramento-San Joaquin Delta of northern California, we examined the feasibility of using constructed wetlands receiving drainage water treated with metal-based coagulants to accrete mineral material along with wetland biomass, while also sequestering carbon in wetland sediment. Nine field-scale wetlands were constructed which received local drainage water that was either untreated (control), or treated with polyaluminum chloride (PAC) or iron sulfate (FeSO4) coagulants. After 23 months of flooding and coagulant treatment, sediment samples were collected near the inlet, middle, and outlet of each wetland to determine vertical accretion rates, bulk density, sediment composition, and carbon sequestration rates. Wetlands treated with PAC had the highest and most spatially consistent vertical accretion rates (~6 cm year-1), while the FeSO4 wetlands had similarly high accretion rates near the inlet but rates similar to the untreated wetland (~1.5 cm year-1) at the middle and outlet sites. The composition of the newly accreted sediment in the PAC and FeSO4 treatments was high in the added metal (aluminum and iron, respectively), but the percent metal by weight was similar to native soils of California. As has been observed in other constructed wetlands, the newly accreted sediment material had lower bulk densities than the native soil material (0.04-0.10 g cm-3 versus 0.2-0.3 g cm-3), suggesting these materials will consolidate over time. Finally, this technology accelerated carbon burial, with rates in PAC treated wetland (0.63 kg C m-2 yr-1) over 2-fold greater than the untreated control (0.28 kg C m-2 yr-1). This study demonstrates the feasibility of using constructed wetlands treated with coagulants to reverse subsidence by accreting the
Directory of Open Access Journals (Sweden)
A. Mesdaghinia, M. T. Rafiee, F. Vaezi and A. H. Mahvi
2005-07-01
Full Text Available Although the removal of colloidal particles continues to be an important reason for using coagulation, a newer objective, the removal of natural organic matter (NOM to reduce the formation of disinfection by-products (DBPs, is growing in importance. Enhanced coagulation is thus introduced to most water utilities treating surface water. Bench-scale experiments were conducted to compare the effectiveness of alum and ferric chloride in removing DBPs precursors from eight synthetic water samples, each representing a different element of the USEPA’s 3×3 enhanced coagulation matrix. The effect of enhanced coagulation on the residual metal (aluminum/iron concentration in the treated water was assessed as well. The removal of total organic carbon (TOC was dependent on the coagulant type and was enhanced with increasing coagulant dose, but the latter had no further considerable effect in case of increasing to high levels. For all the treated samples coagulation with ferric chloride proved to be more effective than alum at similar doses and the mean values of treatment efficiencies were 51% and 32% for ferric chloride and alum, respectively. Ferric chloride was therefore considered the better chemical for enhancing the coagulation process. Besides, due to less production of sludge by this coagulant, it would be predicted that treatment plants would be confronted to fewer problems with respect to final sludge disposal. Measurements of residual metal in treated water indicated that iron and aluminum concentrations had been increased as expected but the quality of water concerning the residual metal deteriorated much more in cases of under-dosing. Despite expecting high residual Al and Fe concentrations under enhanced coagulation, metal concentrations were frequently remained low and were not increased appreciably.
Energy Technology Data Exchange (ETDEWEB)
Jang, M.; Lee, H.J.; Shim, Y. [Korean Mine Reclamation Corporation MIRECO, Seoul (Republic of Korea)
2010-07-01
The processes of coagulation and flocculation using high molecular weight long-chain polymers were applied to treat mine water having fine flocs of which about 93% of the total mass was less than 3.02 {mu} m, representing the size distribution of fine particles. Six different combinations of acryl-type anionic flocculants and polyamine-type cationic coagulants were selected to conduct kinetic tests on turbidity removal in mine water. Optimization studies on the types and concentrations of the coagulant and flocculant showed that the highest rate of turbidity removal was obtained with 10 mg L{sup -1} FL-2949 (coagulant) and 12 mg L{sup -1} A333E (flocculant), which was about 14.4 and 866.7 times higher than that obtained with A333E alone and that obtained through natural precipitation by gravity, respectively. With this optimized condition, the turbidity of mine water was reduced to 0 NTU within 20 min. Zeta potential measurements were conducted to elucidate the removal mechanism of the fine particles, and they revealed that there was a strong linear relationship between the removal rate of each pair of coagulant and flocculant application and the zeta potential differences that were obtained by subtracting the zeta potential of flocculant-treated mine water from the zeta potential of coagulant-treated mine water. Accordingly, through an optimization process, coagulation-flocculation by use of polymers could be advantageous to mine water treatment, because the process rapidly removes fine particles in mine water and only requires a small-scale plant for set-up purposes owing to the short retention time in the process.
Infrared coagulation versus rubber band ligation in early stage hemorrhoids.
Gupta, P J
2003-10-01
The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54) or infrared coagulation (N = 46). Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years). The mean duration of disease was 17.5 months (range 12 to 34 months). The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale). Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059). The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03), but also had a higher recurrence or failure rate (P = 0.03). Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.
Treatment of the oily produced water (OPW using coagulant mixtures
Directory of Open Access Journals (Sweden)
R. Hosny
2016-09-01
Full Text Available Treatment of the oily produced water (OPW before injection into oil reservoirs is necessary to reduce formation damage. This can be done using chemo-physical process to minimize the oil droplets in water. In this respect, this work aims to extract natural polymer (chitosan from shrimp shells and mix it with coagulants (chitosan/carboxy methyl cellulose and chitosan/aluminum sulfate to adsorb oil from OPW. Adsorption experiments were carried out in batch mode firstly to choose the best coagulants in water treatment, also to investigate the effects of pH on the adsorption uptake, adsorbent dosage, coagulant mixture doses and contact time. It was found that the oil removal by chitosan reached 96.35% and 59% at pH = 4 and pH = 9, respectively. The ability of chitosan to remove oil was increased after adding different coagulants CMC/or aluminum sulfate at average mixing time between 30 and 60 min. It was also found that the highest removal efficiency of chitosan/CMC is 99% at (90% chitosan: 10% CMC and chitosan/Al2(SO43 is 85% at (80% chitosan: 20% Al2(SO43. The SEM photographs of chitosan, chitosan/CMC and chitosan/Al2(SO43 mixture as oil removal showed that chitosan/Al2(SO43 lies between chitosan alone and chitosan/CMC mixture. Generally chitosan/CMC characterized significantly by its high ability to adsorb petroleum oil and suspended solids from OPW, additionally, reduces the economic cost of water treatment.
Origin of serpin-mediated regulation of coagulation and blood pressure.
Directory of Open Access Journals (Sweden)
Yunjie Wang
Full Text Available Vertebrates evolved an endothelium-lined hemostatic system and a pump-driven pressurized circulation with a finely-balanced coagulation cascade and elaborate blood pressure control over the past 500 million years. Genome analyses have identified principal components of the ancestral coagulation system, however, how this complex trait was originally regulated is largely unknown. Likewise, little is known about the roots of blood pressure control in vertebrates. Here we studied three members of the serpin superfamily that interfere with procoagulant activity and blood pressure of lampreys, a group of basal vertebrates. Angiotensinogen from these jawless fish was found to fulfill a dual role by operating as a highly selective thrombin inhibitor that is activated by heparin-related glycosaminoglycans, and concurrently by serving as source of effector peptides that activate type 1 angiotensin receptors. Lampreys, uniquely among vertebrates, thus use angiotensinogen for interference with both coagulation and osmo- and pressure regulation. Heparin cofactor II from lampreys, in contrast to its paralogue angiotensinogen, is preferentially activated by dermatan sulfate, suggesting that these two serpins affect different facets of thrombin's multiple roles. Lampreys also express a lineage-specific serpin with anti-factor Xa activity, which demonstrates that another important procoagulant enzyme is under inhibitory control. Comparative genomics suggests that orthologues of these three serpins were key components of the ancestral hemostatic system. It appears that, early in vertebrate evolution, coagulation and osmo- and pressure regulation crosstalked through antiproteolytically active angiotensinogen, a feature that was lost during vertebrate radiation, though in gnathostomes interplay between these traits is effective.
International Nuclear Information System (INIS)
Baeza, A.; Miro, C.; Salas, A.; Fernandez, M.; Herranz, M.; Legarda, F.
2004-01-01
Effectiveness of potable water treatment processes that consist of the stages of coagulation-flocculation-decantation, using iron-based coagulants, in eliminating gamma-emitting man-made radioisotopes of cesium, strontium, and americium from two natural waters with different degrees of mineralization was studied. The resulting decontamination was found to depend on the chemical behavior of each of the radionuclides considered, on the pH at which the process of coagulation is carried out, and on the concentration of the other stable cations present. (author)
International Nuclear Information System (INIS)
Stella, M.S.; Comparato, D.; Camici, M.; Evangelisti, L.; Gaudio, V.; De Negri, F.; Talarico, L.; Giusti, C.; Morelli, G.
1991-01-01
Disseminated intravascular coagulation (DIC) is a severe life-threatening acute bleeding disorder. Traumatized tissues, tumors, necrotic tissues, or bacterial endotoxines release similar material in the blood to the tissutal factors activating the coagulation cascade. This preliminary study was aimed at verifying the risk of DIV in patients undergoing US-guided transperineal prostatic biopsy with Chiba and Tru-Cut needles. To evaluate the activation degree of coagulation factors in the circulation, the authors measured the concentrations of urinary fibrin degradation products in 10 patients undergoing US-guided transperineal prostatic biopsy, both before and after biopsy, every second hour, for 24 hours. Every tube of urine sample contained soya bean trypsin inhibitor and bovine thrombin to prevent any further fibrin degradation during incubation period for the possible presence of blood in urine samples. The results showed that 7/10 patients had marked increase in urinary fibrin degradation product levels (up to 800 XXXX%), with a 3-phase trend: early peak after 2-6 hours, middle peak after 6-14 hours, and late peak after 18-24 hours, which proved the activation of the coagulation cascade
Jeong, Sanghyun; Sathasivan, Arumugam; Kastl, George; Shim, Wang Geun; Vigneswaran, Saravanamuthu
2014-01-01
Coagulation removes colloidal matters and dissolved organic carbon (DOC) which can cause irreversible membrane fouling. However, how DOC is removed by coagulant is not well-known. Jar test was used to study the removal of hydrophobic and hydrophilic DOC fractions at various doses (0.5-8.0 mg-Fe(+3) L(-1)) of ferric chloride (FeCl3) and pH (5.0-9.0). Natural organic matter (NOM) in seawater and treated seawater were fractionated by liquid chromatography-organic carbon detector (LC-OCD). Compared to surface water, the removal of DOC in seawater by coagulation was remarkably different. Majority of DOC could be easily removed with very low coagulant dose (fraction (HB) was better removed at high pH while hydrophilic fraction (HF) was better removed at low pH. A modified model of Kastl et al. (2004) which assumed that the removal occurred by adsorption of un-dissociated compounds onto ferric hydroxide was formulated and successfully validated against the jar test data. Copyright © 2013 Elsevier Ltd. All rights reserved.
Rheological behavior of raw natural rubber coagulated by microorganisms
Directory of Open Access Journals (Sweden)
Zhifen Wang
2014-01-01
Full Text Available Tests of the strain sweep, frequency sweep and stress relaxation for raw natural rubber coagulated by microorganisms (NR-m and raw natural rubber coagulated by acid (NR-a were carried out with the use of a rubber process analyzer (RPA. The results showed that the storage torque, complex viscosity of NR-m were higher than those of NR-a while the loss factor was lower. The effect of temperature on viscosity of raw NR was studied following the Arrhenious-Frenkel-Eyring model. The viscous flow behavior of NR-m was poorer than those of NR-a. Furthermore, stress relaxation measurements of raw NR showed a longer period of relaxation for NR-m.
Engineering the substrate and inhibitor specificities of human coagulation Factor VIIa
DEFF Research Database (Denmark)
Larsen, Katrine S; Østergaard, Henrik; Bjelke, Jais R
2007-01-01
The remarkably high specificity of the coagulation proteases towards macromolecular substrates is provided by numerous interactions involving the catalytic groove and remote exosites. For FVIIa [activated FVII (Factor VII)], the principal initiator of coagulation via the extrinsic pathway, several...... for FVIIa by marked changes in primary substrate specificity and decreased rates of antithrombin III inhibition. Interestingly, these changes do not necessarily coincide with an altered ability to activate Factor X, demonstrating that inhibitor and macromolecular substrate selectivity may be engineered...
Early activation of the coagulation system during lower body negative pressure
DEFF Research Database (Denmark)
Zaar, M; Johansson, P I; Nielsen, L B
2009-01-01
We considered that a moderate reduction of the central blood volume (CBV) may activate the coagulation system. Lower body negative pressure (LBNP) is a non-invasive means of reducing CBV and, thereby, simulates haemorrhage. We tested the hypothesis that coagulation markers would increase following...... moderate hypovolemia by exposing 10 healthy male volunteers to 10 min of 30 mmHg LBNP. Thoracic electrical impedance increased during LBNP (by 2.6 +/- 0.7 Omega, mean +/- SD; P pressure decreased (84 +/- 5 to 80...
Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis
Mucci, Maira; Noyma, Natalia Pessoa; de Magalhaes, Leonardo; Miranda, Marcela; van Oosterhout, Frank; Guedes, Iame Alves; Huszar, Vera L. M.; Marinho, Marcelo Manzi; Lürling, Miquel
2017-01-01
Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show
Coagulation Status in Hidradenitis Suppurativa
DEFF Research Database (Denmark)
Miller, Iben Marie; Johansen, Maria Egede; Mogensen, Ulla B
2015-01-01
BACKGROUND: Chronic inflammatory diseases other than hidradenitis suppurativa (HS) have been associated with prothrombotic/hypercoagulable status. OBJECTIVE: To investigate a possible association between the chronic inflammatory skin disease HS and prothrombotic/hypercoagulable state. METHODS: We.......3432). CONCLUSION: We did not find an association between HS and prothrombotic/hypercoagulable status. Thus, thrombocytes may not be activated in HS. Furthermore, INR may not be affected in HS, suggesting that intrinsic and vitamin K-dependent coagulation factors appear unaffected....
Coagulation effectiveness of graphene oxide for the removal of turbidity from raw surface water.
Aboubaraka, Abdelmeguid E; Aboelfetoh, Eman F; Ebeid, El-Zeiny M
2017-08-01
This study presents the performance of graphene oxide (GO) as a coagulant in turbidity removal from naturally and artificially turbid raw surface water. GO is considered an excellent alternative to alum, the more common coagulant used in water treatment processes, to reduce the environmental release of aluminum. Effects of GO dosage, pH, and temperature on its coagulation ability were studied to determine the ideal turbidity removal conditions. The turbidity removal was ≥95% for all levels of turbid raw surface water (20, 100, and 200 NTU) at optimum conditions. The role of alkalinity in inducing turbidity removal by GO coagulation was much more pronounced upon using raw surface water samples compared with that using artificially turbid deionized water samples. Moreover, GO demonstrated high-performance removal of biological contaminants such as algae, heterotrophic bacteria, and fecal coliform bacteria by 99.0%, 98.8% and 96.0%, respectively, at a dosage of 40 mg/L. Concerning the possible environmental release of GO into the treated water following filtration process, there was no residual GO in a wide range of pH values. The outcomes of the study highlight the excellent coagulation performance of GO for the removal of turbidity and biological contaminants from raw surface water. Copyright © 2017 Elsevier Ltd. All rights reserved.
Removal of arsenic and iron removal from drinking water using coagulation and biological treatment.
Pramanik, Biplob Kumar; Pramanik, Sagor Kumar; Suja, Fatihah
2016-02-01
Effects of biological activated carbon (BAC), biological aerated filter (BAF), alum coagulation and Moringa oleifera coagulation were investigated to remove iron and arsenic contaminants from drinking water. At an initial dose of 5 mg/L, the removal efficiency for arsenic and iron was 63% and 58% respectively using alum, and 47% and 41% respectively using Moringa oleifera. The removal of both contaminants increased with the increase in coagulant dose and decrease in pH. Biological processes were more effective in removing these contaminants than coagulation. Compared to BAF, BAC gave greater removal of both arsenic and iron, removing 85% and 74%, respectively. Longer contact time for both processes could reduce the greater concentration of arsenic and iron contaminants. The addition of coagulation (at 5 mg/L dosage) and a biological process (with 15 or 60 min contact time) could significantly increase removal efficiency, and the maximum removal was observed for the combination of alum and BAC treatment (60 min contact time), with 100% and 98.56% for arsenic and iron respectively. The reduction efficiency of arsenic and iron reduced with the increase in the concentration of dissolved organics in the feedwater due to the adsorption competition between organic molecules and heavy metals.
Condutivity effect in electro-coagulation-flotation applied to physico-chemical wastewater treatment
Francisco Javier Cuba Terán; Mário Luiz Rodrigues Foco
2007-01-01
This study reports on the effect of conductivity on the simultaneous applicability of water electrolysis , chemical coagulation and flotation fundamentals in the treatment of wastewater with large amounts of suspended matter, characterizing electro-coagulation-flotation (ECF) . Results from experiments carried out in a pilot study implanted and operated in the Laboratory of Environment Control (LCA), at the State University of Campinas in Limeira are presented. ECF was developed in an electro...
Reeve, A. S.; Martin, D.; Smith, S. M.
2013-12-01
Surface waters within the Sebago Lake watershed (southern Maine, USA) provide a variety of economically and intrinsically valuable recreational, commercial and environmental services. Different stakeholder groups for the 118 km2 Sebago Lake and surrounding watershed advocate for different lake and watershed management strategies, focusing on the operation of a dam at the outflow from Sebago Lake. While lake level in Sebago Lake has been monitored for over a century, limited data is available on the hydrologic processes that drive lake level and therefore impact how dam operation (and other changes to the region) will influence the hydroperiod of the lake. To fill this information gap several tasks were undertaken including: 1) deploying data logging pressure transducers to continuously monitor stream stage in nine tributaries, 2) measuring stream discharge at these sites to create rating curves for the nine tributaries, and using the resulting continuous discharge records to 3) calibrate lumped parameter computer models based on the GR4J model, modified to include a degree-day snowmelt routine. These lumped parameter models have been integrated with a simple lake water-balance model to estimate lake level and its response to different scenarios including dam management strategies. To date, about three years of stream stage data have been used to estimate stream discharge in all monitored tributaries (data collection is ongoing). Baseflow separation indices (BFI) for 2010 and 2011 using the USGS software PART and the Eckhart digital filter in WHAT range from 0.80-0.86 in the Crooked River and Richmill Outlet,followed by Northwest (0.75) and Muddy (0.53-0.56) Rivers, with the lowest BFI measured in Sticky River (0.41-0.56). The BFI values indicate most streams have significant groundwater (or other storage) inputs. The lumped parameter watershed model has been calibrated for four streams (Nash-Sutcliffe = 0.4 to 0.9), with the other major tributaries containing
Chitosan as coagulant on cyanobacteria in lake restoration management may cause rapid cell lysis
Nunes Teixeira Mucci, Maira; Noyma, Natalia Pessoa; Magalhães, de Leonardo; Miranda, Marcela; Oosterhout, van Frank; Guedes, Iamê Alves; Huszar, Vera L.M.; Marinho, Marcelo Manzi; Lürling, Miquel
2017-01-01
Combining coagulant and ballast to remove cyanobacteria from the water column is a promising restoration technique to mitigate cyanobacterial nuisance in surface waters. The organic, biodegradable polymer chitosan has been promoted as a coagulant and is viewed as non-toxic. In this study, we show
International Nuclear Information System (INIS)
Subiarto; Herlan Martono
2007-01-01
Research about treatment of industrial liquid waste of steel plating by coagulation-flocculation using sodium biphosphate have been conducted. The purpose of the treatment was the content reduction of Cr, Ni, and Cu in the liquid waste, so that produced effluent with Cr, Ni, and Cu content until they laid under mutual standard. The variables studied in this process were the solution pH, the coagulant/waste volume comparison, the speed of the fast stirring, and the time of the fast stirring. Optimum separation efficiency on coagulation-flocculation process of liquid waste of steel plating using sodium biphosphate at the condition of solution ph 9, coagulant/waste volume comparation 1.50, the speed of the fast stirring 400 rpm, and the time of fast stirring is 5 minute. Low stirring was conducted at 60 rpm for 60 minute. The yields of optimum separation efficiency in this condition were 99.48 % for Cr, 99.51 % for Ni, and 99.03 % for Cu. (author)
Energy Technology Data Exchange (ETDEWEB)
Yoo, E.S.; Yoon, I.M. [School of Natural Sciences, Honam Univ., Gwangju (Korea)
2005-07-01
This study was conducted to test the performance of various combinations of coagulants for effective wastewater treatment of the tire recycling industry. From the jar-test results, two kinds of coagulants, namely AlSi-1 and PASi-1, were found to be effective in decreasing BOD and COD{sub Cr} values from the polluted wastewater among various combinations of coagulants. In comparison to Al-based or Si-based singular salts, the Si-Al combined salts (PASi-1) exhibited a higher removal efficiency of 90% turbidity, 93% SS, 70 {proportional_to} 85% BOD{sub 5} and 85 {proportional_to} 91% COD{sub Cr} at 15 {+-} 2 C, pH7.5 {proportional_to} 9.5 and 2.0 mM of coagulant dosage. At 30 {+-} 2 C of tire recycling effluents, the combination effect was clearly shown in the removal of COD{sub Cr} over a wider range of pH. The reaction mechanisms of AlSi-1 and PASi-1 were also schematically studied. (orig.)
Treatment of water turbidity and bacteria by using a coagulant extracted from Plantago ovata
Directory of Open Access Journals (Sweden)
Bahman Ramavandi
2014-08-01
Full Text Available A biocoagulant was successfully extracted from Plantago ovata by using an FeCl3-induced crude extract (FCE. The potential of FCE to act as a natural coagulant was tested for clarification using the turbid water of a river. Experimental tests were performed to evaluate the effects of turbidity concentration, coagulant quantity, water pH, and humic acid concentration on the coagulation of water turbidity by FCE. The maximum turbidity removal was occurred at water pH<8. At the optimum dosage of FCE, only 0.8 mg/L of dissolved organic carbon was released to the treated water. An increase in the humic acid led to the promotion of the water turbidity removal. Results demonstrated that the FCE removed more than 95.6% of all initial turbidity concentrations (50–300 NTU. High bacteriological quality was achieved in the treated water. FCE as an eco-friendly biocoagulant was revealed to be a very efficient coagulant for removing turbidity from waters.
Cultural factors associated with the management of breast lumps amongst Xhosa women
Directory of Open Access Journals (Sweden)
Nosipho Mdondolo
2003-11-01
Full Text Available A qualitative research design and an ethno-nursing research method were used to identify cultural factors influencing Xhosa women’s health seeking behaviours associated with breast lumps. Opsomming ’n Kwalitatiewe navorsingsontwerp en ’n etnoverpleegkundige navorsingsmetode is gebruik. Die doel was om te bepaal watter kulturele faktore Xhosa vroue se strewe na welstand, wat in verband staan met ’n borsvergroeisel, beïnvloed. *Please note: This is a reduced version of the abstract. Please refer to PDF for full text.
Directory of Open Access Journals (Sweden)
Murat Yılmaz
2011-08-01
Full Text Available Bleeding and coagulation disorders related to trauma are pathological processes which are frequently seen and increase mortality. For the purpose, trauma patients should be protected from hypoperfusion, hypothermia, acidosis and hemodilution which may aggravate the increase in physiological responses to trauma as anticoagulation and fibrinolysis. Performing damage control surgery and resuscitation and transfusion of adequate blood and blood products in terms of amount and content as stated in protocols may increase the rate of survival. Medical treatments augmenting fibrin formation (fibrinogen, desmopressin, factor VIIa or preventing fibrin degradation (tranexamic acid have been proposed in selected cases but the efficacy of these agents in trauma patients are not proven. (Journal of the Turkish Society Intensive Care 2011; 9:71-6
Coagulation disorders in the patients with deep vein thrombosis of lower extremity
Directory of Open Access Journals (Sweden)
Milić Dragan J.
2003-01-01
Full Text Available PURPOSE Venous thromboembolism is a relevant social and health care problem for its high incidence, pulmonary embolism-related mortality and long-term sequelae which may be disabling (post-thrombotic syndrome and ulceration. PROCEDURES The aim of our work was to establish the presence of coagulation disorders (hypercoagulable states in the patients with deep vein thrombosis (DVT of the leg. Prospectively we have analyzed a group of 30 patients with echosono-graphicaly verified DVT of the leg who were admitted to the department of vascular surgery from August 1st 2000 to July 31st 2001.The following parameters were monitored: prothrombin time (PT partial thromboplastin time (PTT, fibrinogen (Fib, alpha 2 antiplasmin (A-2 AP, D-dimer (DD, antithrombin III (AT III and factor VII. FINDINGS Activation of the coagulation process was registered. The values of monitored coagulation parameters are shown in table 1. Plasma levels of monitored parameters in the patients with DVT of the leg were significantly higher than in the control subjects. CONCLUSION In patients with a DVT a hypercoagulable state is common finding. Some parameters of coagulation activity such as D-dimer might be of great interest in the diagnostic strategy of DVT.
Directory of Open Access Journals (Sweden)
Wan Haslindawani W
2010-01-01
Full Text Available Introduction: The appropriate use of blood and blood products means the transfusion of safe blood products only to treat a condition leading to significant morbidity or mortality, which cannot be prevented or managed effectively by other means. The safety and effectiveness of transfusion depend on the appropriate clinical use of blood and blood products. This study was conducted to review the practice of fresh frozen plasma usage (FFP for transfusion, based on the coagulation profile, requested by various departments in the Hospital Universiti Sains Malaysia (HUSM. Methodology: A retrospective review of blood bank records and coagulation profile results of the patients given FFP from October to December 2006, in Hospital USM was undertaken. The criteria set by the College of American Pathologists in 1994, were used as the guidelines. Results: One thousand six hundred and ninety-eight units of FFP were used during this study period. Only 806 (47.47% FFP units were deemed appropriate. 20.38% were based on studies without any coagulation tests prior to transfusion and 21.13% were transfused for mild prolongation of coagulation test results. About 6.41% requested FFP in the setting of normal coagulation results. Conclusion: Our results showed that a significant proportion of the FFP transfusion was not guided by the coagulation profile. We recommend that a continuous education on FFP transfusion may help to guide the appropriate request for FFP.
Directory of Open Access Journals (Sweden)
Mohammad Taghi Ghaneian
2017-09-01
Full Text Available In this study, the feasibility of using coagulation, flocculation, and sedimentation (CF-S for advanced treatment of secondary effluent released from the Yazd Intermittent Cycle Extended Aeration System was investigated. Four coagulants including ferric chloride (FeCl3, polyaluminum chloride (PAC, ferrous sulfate (FeSo4, and potassium ferrate (K2FeSo4 along with Gflog C-150 as flocculant polymer were used. In this study, returned chemical sludge was considered as a modification. Preliminary CF-S processes showed that FeSO4 and K2FeO4 had low removal efficiencies. Thus, these two coagulants were abandoned and CF-S processes were continued only with PAC and FeCl3 coagulants which had higher efficiencies in the removal of biological oxygen demand (BOD5, chemical oxygen demand (COD, total suspended solids (TSS, and turbidity. Removal efficiency was higher when half of the chemical producing sludge was returned as compared with using both coagulants simultaneously along with 2 mg L−1 of C-150 as flocculant. In the optimum dosage, when half of PAC and FeCl3 sludge were returned, the volume of produced sludge was reduced by 40% and 28%, respectively, as compared without returned sludge. For the PAC coagulant in the optimum dosage with half of the sludge returned, all 2012 EPA standards of irrigation were met for both ‘processed and non-processed type’ agricultural crops.
Salloum-Asfar, Salam; Boelen, Anita; Reitsma, Pieter H.; van Vlijmen, Bart J. M.
2015-01-01
Thyroid dysfunction is associated with changes in coagulation. The aim of our study was to gain more insight into the role of thyroid hormone in coagulation control. C57Black/6J mice received a low-iodine diet and drinking water supplemented with perchlorate to suppress endogenous triiodothyronine
Lim, Hyunjung; Nam, Jeonghun; Xue, Shubin; Shin, Sehyun
2011-01-01
Even though blood coagulation can be tested by various methods and techniques, the effect of RBC aggregation on blood coagulation is not fully understood. The present study monitored clot formation in a microchip-based light transmission aggregometer. Citrated blood samples with and without the addition of calcium ion solution were initially disaggregated by rotating a stirrer in the microchip. After abrupt stop of the rotating stirrer, the transmitted light intensity over time was recorded. The syllectogram (light intensity vs. time graph) manifested a rapid increase that is associated with RBC aggregation followed by a decrease that is associated with blood coagulation. The time to reach the peak point was used as a new index of coagulation time (CT) and ranged from 200 to 500 seconds in the present measurements. The CT was inversely proportional to the concentration of fibrinogen, which enhances RBC aggregation. In addition, the CT was inversely proportional to the hematocrit, which is similar to the case of the prothrombin time (PT), as measured by a commercial coagulometer. Thus, we carefully concluded that RBC aggregation should be considered in tests of blood coagulation.
Directory of Open Access Journals (Sweden)
Abdolmotaleb Seid Mohammadi
2014-12-01
Full Text Available Chitosan, a biodegradable polymer, is used as an eco-friendly coagulant in a wide variety of applications in water and wastewater treatment. The present study aimed to investigate the effect of chitosan as a coagulant aid combined with poly aluminum chloride (PAC to enhance coagulating efficiency for bentonite suspensions. A conventional jar test apparatus was used for the tests. The effect of various operational parameters, such as initial pH of the solution (5-9.5, dosage of chitosan (0.5-3.5 mg/L, dosage of PAC (5-35 mg/L and initial turbidity (50-200 NTU were investigated. The maximum turbidity removal rates were obtained as pH 8.5 for PAC and pH 7.5 for combined PAC and chitosan (CPC. The coagulating efficiency of bentonite using PAC and CPA was found to decrease with an increase in the pH value of the solutions. The maximum turbidity removal rate was achieved in coagulating by PAC (30 mg/L alone, and PAC (20 mg/L combined with chitosan (2.5 mg/L as coagulant aid with the removal rate of 87% and 96%, respectively. The optimum dosage of chitosan required to obtain the highest removal rate was 2.5 mg/L. Hence, using chitosan as a coagulant aid can not only reduce the required amount of coagulant (35% but can also enhance the removal turbidity efficiency.
Mallik, Suman; Prasad, Ramesh; Bhattacharya, Anindita; Sen, Prosenjit
2018-05-10
Natural phosphatidylserine (PS), which contains two chiral centers, enhances blood coagulation. However, the process by which PS enhanced blood coagulation is not completely understood. An efficient and flexible synthetic route has been developed to synthesize all of the possible stereoisomers of PS. In this study, we examined the role of PS chiral centers in modulating the activity of the tissue factor (TF)-factor VIIa coagulation initiation complex. Full length TF was relipidated with phosphatidylcholine, and the synthesized PS isomers were individually used to estimate the procoagulant activity of the TF-FVIIa complex via a FXa generation assay. The results revealed that the initiation complex activity was stereoselective and had increased sensitivity to the configuration of the PS glycerol backbone due to optimal protein-lipid interactions.
Blood coagulation in hemophilia A and hemophilia C
Cawthern, K. M.; van 't Veer, C.; Lock, J. B.; DiLorenzo, M. E.; Branda, R. F.; Mann, K. G.
1998-01-01
Tissue factor (TF)-induced coagulation was compared in contact pathway suppressed human blood from normal, factor VIII-deficient, and factor XI-deficient donors. The progress of the reaction was analyzed in quenched samples by immunoassay and immunoblotting for fibrinopeptide A (FPA),
optimization of coagulation-flocculation process for colour removal
African Journals Online (AJOL)
user
2DEPARTMENT OF CHEMICAL ENGINEERING, NNAMDI AZIKIWE UNIVERSITY, AWKA, ANAMBRA STATE. ... The ability of organic polymer rich coagulants for colour removal from acid dye was studied. ... Response surface methodology (RSM) using face-centered ...... successfully applied for modeling and optimizing the.
Mass deformed world-sheet action of semi local vortices
Energy Technology Data Exchange (ETDEWEB)
Jiang, Yunguo [School of Space Science and Physics, Shandong University at Weihai,264209 Weihai (China); Shandong Provincial Key Laboratory of Optical Astronomy and Solar-Terrestrial Environment,264209 Weihai (China)
2014-02-10
The mass deformed effective world-sheet theory of semi local vortices was constructed via the field theoretical method. By Euler-Lagrangian equations, the Ansatze for both the gauge field and the adjoint scalar were solved, this ensures that zero modes of vortices are minimal excitations of the system. Up to the 1/g{sup 2} order, all profiles are solved. The mass deformed effective action was obtained by integrating out the transverse plane of the vortex string. The effective theory interpolates between the local vortex and the lump. Respecting certain normalization conditions, the effective theory shows a Seiberg-like duality, which agrees with the result of the Kähler quotient construction.
Infrared coagulation versus rubber band ligation in early stage hemorrhoids
Directory of Open Access Journals (Sweden)
P.J. Gupta
2003-10-01
Full Text Available The ideal therapy for early stages of hemorrhoids is always debated. Some are more effective but are more painful, others are less painful but their efficacy is also lower. Thus, comfort or efficacy is a major concern. In the present randomized study, a comparison is made between infrared coagulation and rubber band ligation in terms of effectiveness and discomfort. One hundred patients with second degree bleeding piles were randomized prospectively to either rubber band ligation (N = 54 or infrared coagulation (N = 46. Parameters measured included postoperative discomfort and pain, time to return to work, relief in incidence of bleeding, and recurrence rate. The mean age was 38 years (range 19-68 years. The mean duration of disease was 17.5 months (range 12 to 34 months. The number of male patients was double that of females. Postoperative pain during the first week was more intense in the band ligation group (2-5 vs 0-3 on a visual analogue scale. Post-defecation pain was more intense with band ligation and so was rectal tenesmus (P = 0.0059. The patients in the infrared coagulation group resumed their duties earlier (2 vs 4 days, P = 0.03, but also had a higher recurrence or failure rate (P = 0.03. Thus, we conclude that band ligation, although more effective in controlling symptoms and obliterating hemorrhoids, is associated with more pain and discomfort to the patient. As infrared coagulation can be conveniently repeated in case of recurrence, it could be considered to be a suitable alternative office procedure for the treatment of early stage hemorrhoids.
Evaluation of Disseminated Intravascular Coagulation in the Craniocerebral Traumas
Directory of Open Access Journals (Sweden)
Faruk Altinel
2014-06-01
Full Text Available Traumatic injury is one of the most important cause of disseminated intravascular coagulation (DIC. It occurs because of blood loss and hemodilution due to fluid resuscitation. The incidence of trauma associated DIC is mainly higher in the craniocerebral traumas. Even though craniocerebral trauma related DIC is well defined, the pathophysiology has been poorly characterized in the literature. Due to the fact that brain tissue is highly significant for procoagulant molecules, craniocerebral traumas are closely related to DIC. In the current study, 30 patients admitted to emergency room have been considered on the first and fifth day of admission to the hospital for the coagulation tests to evaluate DIC in both two groups. [Cukurova Med J 2014; 39(3.000: 488-495
Lauder, S.N.; Allen-Redpath, K.; Slatter, D.A.; Aldrovandi, M.; O'Connor, A.; Farewell, D.; Percy, C.L.; Molhoek, J.E.; Rannikko, S.; Tyrrell, V.J.; Ferla, S.; Milne, G.L.; Poole, A.W.; Thomas, C.P.; Obaji, S.; Taylor, P.R.; Jones, S.A.; Groot, P.G. de; Urbanus, R.T.; Horkko, S.; Uderhardt, S.; Ackermann, J.; Jenkins, P.V.; Brancale, A.; Kronke, G.; Collins, P.W.; O'Donnell, V.B.
2017-01-01
Blood coagulation functions as part of the innate immune system by preventing bacterial invasion, and it is critical to stopping blood loss (hemostasis). Coagulation involves the external membrane surface of activated platelets and leukocytes. Using lipidomic, genetic, biochemical, and mathematical
Levi, Marcel; de Jonge, Evert; van der Poll, Tom
2002-01-01
Disseminated intravascular coagulation (DIC) is a syndrome characterized by systemic intravascular activation of coagulation, leading to widespread deposition of fibrin in the circulation. Recent knowledge on important pathogenetic mechanisms that may lead to DIC has resulted in novel preventive and
Microwave coagulation therapy and drug injection to treat splenic injury.
Zhang, Guoming; Sun, Yuanyuan; Yu, Jie; Dong, Lei; Mu, Nannan; Liu, Xiaohong; Liu, Lanfen; Zhang, Yan; Wang, Xiaofei; Liang, Ping
2014-01-01
The present study compares the efficacy of 915- and 2450-MHz contrast-enhanced ultrasound (CEUS)-guided percutaneous microwave coagulation with that of CEUS-guided thrombin injection for the treatment of trauma-induced spleen hemorrhage. In a canine splenic artery hemorrhage model with two levels of arterial diameter (A, microwaves and drug injection. Therapy efficacy was measured by comparing bleeding rate, hemostatic time, bleeding index, bleeding volume, and pathology. The most efficient technique was CEUS-guided 915-MHz percutaneous microwave coagulation therapy in terms of action time and total blood loss. The success rate of the 915-MHz microwave group was higher than that of the 2450-MHz microwave and the drug injection groups (except A level, P microwave group than those in the 2450-MHz microwave and drug injection groups (P microwave group, but pathologic changes of light injury could be seen in the other groups. The present study provides evidence that microwave coagulation therapy is more efficient than thrombin injection for the treatment of splenic hemorrhage. Furthermore, treatment with 915-MHz microwaves stops bleeding more rapidly and generates a wider cauterization zone than does treatment with 2450-MHz microwaves. Copyright © 2014 Elsevier Inc. All rights reserved.
Kapse, Gaurav; Patoliya, Pruthvi; Samadder, S R
2017-03-01
The huge quantity of effluent generated in coal washing processes contains large amount of suspended and dissolved solids, clay minerals, coal fines and other impurities associated with raw coal. The present system of recirculation of the effluent is found to be ineffective in removing colloidal fines, which is the major part of the impurities present in washery effluent. Hence, there is a need for the assessment of a better technique for an efficient removal of these impurities. This study deals with detailed characterisation of coal washery effluent and fine particles present in it. For efficient removal of impurities, the suitability of biocoag-flocculation process using Moringa oleifera seed biomass as a natural coagulant was examined. Various doses of M. oleifera ranging from 0.2 to 3 mL/L were used in order to determine the optimal conditions. The impact of the variations in pH of the effluent (2-10), contact time (5-30 min), settlement time (5-50 min), temperature (10-50 °C) and the effluent dilution (1:0-1:5) was also assessed to optimise the treatment process. Post treatment analysis was carried out for determination of the different parameters such as pH, conductivity, turbidity, solids and settling velocity. Excellent reduction in turbidity (97.42%) and suspended solids (97.78%) was observed at an optimum dose of M. oleifera seed coagulant of 0.8 mL/L with an optimum contact time of 15 and at 20 min of settling time. In comparison with very few past studies of M. oleifera in the treatment of coal washery effluent with high dose and inadequate removal, this study stands to be a major highlight with low dose and high removal of the impurities. M. oleifera coagulant is considered to be an environment-friendly material, therefore, its application is recommended for simple and efficient treatment of coal washery effluent.
New Procedure to Develop Lumped Kinetic Models for Heavy Fuel Oil Combustion
Han, Yunqing
2016-09-20
A new procedure to develop accurate lumped kinetic models for complex fuels is proposed, and applied to the experimental data of the heavy fuel oil measured by thermogravimetry. The new procedure is based on the pseudocomponents representing different reaction stages, which are determined by a systematic optimization process to ensure that the separation of different reaction stages with highest accuracy. The procedure is implemented and the model prediction was compared against that from a conventional method, yielding a significantly improved agreement with the experimental data. © 2016 American Chemical Society.
Directory of Open Access Journals (Sweden)
Andrea Lauková
2014-08-01
Full Text Available Cow lump cheese represents a traditional Slovak cheese. It belongs to fresh types of cheeses. The aim of this study was to test surviving of commercial probiotic strain Lactobacillus rhamnosus GG in cow lump cheese experimentally infected with L. innocua; (listeriae are contaminants and to check the suitability of GG strain as additive for this product. The counts of GG strain in cow lump cheeses were well balanced during whole experiment. It was found in the counts from 5.48 ± 0.15 to 7.77 ±1.50 log10 cfu/g. Its maximum in cheese was 7.77 ± 1.30 log10 cfu/g on day 7 with stability up to day 14. The identity of GG strain isolated from cheeses was confirmed by PCR. The counts of other lactic acid bacteria were also well balanced during the whole experiment in the experimental cheeses with stability up to day 14. Only in E1/GG cheese, the highest number of LAB was detected (10.60 ±1.26 log10 cfu/g. The count of L. innocua LMG 13568 was not influenced. The pH and lactic acid values were not negatively influenced. Visually, the GG cheese provided a good structure (consistency.It can be disputed that shelf-life of the product could be maintained by this way and/or the product itself with GG strain can be consumed as afunctional food or to serve as a probiotic strain carrier.
The anisotropy of the cosmic background radiation from local dynamic density perturbations
International Nuclear Information System (INIS)
Dyer, C.C.; Ip, P.S.S.
1988-01-01
Contrary to the usual assumption, it is shown here that the anisotropy of the cosmic background radiation need not be dominated by perturbations at the last scattering surface. The results of computer simulations are shown in which local dynamic density perturbations, in the form of Swiss cheese holes with finite, uniform density central lumps, are the main source of anisotropy of the cosmic background radiation. (author)
Directory of Open Access Journals (Sweden)
Lisa M. Casanova
2015-11-01
Full Text Available Point of use (POU household water treatment is increasingly being adopted as a solution for access to safe water. Non-tuberculous Mycobacteria (NTM are found in water, but there is little research on whether NTM survive POU treatment. Mycobacteria may be removed by multi-barrier treatment systems that combine processes such as coagulation, settling and disinfection. This work evaluated removal of a non-tuberculous Mycobacterium (Mycobaterium terrae and a Gram-negative non-acid-fast environmental bacterium (Aeromonas hydrophila by combined coagulation-flocculation disinfection POU treatment. Aeromonas hydrophila showed 7.7 log10 reduction in demand free buffer, 6.8 log10 in natural surface water, and 4 log10 reduction in fecally contaminated surface water. Turbidity after treatment was <1 NTU. There was almost no reduction in levels of viable M. terrae by coagulant-flocculant-disinfectant in natural water after 30 minutes. The lack of Mycobacteria reduction was similar for both combined coagulant-flocculant-disinfectant and hypochlorite alone. A POU coagulant-flocculant-disinfectant treatment effectively reduced A. hydrophila from natural surface waters but not Mycobacteria. These results reinforce previous findings that POU coagulation-flocculation-disinfection is effective against gram-negative enteric bacteria. POU treatment and safe storage interventions may need to take into account risks from viable NTM in treated stored water and consider alternative treatment processes to achieve NTM reductions.